Sample records for external reference system

  1. Superconductor rotor cooling system

    DOEpatents

    Gamble, Bruce B.; Sidi-Yekhlef, Ahmed; Schwall, Robert E.; Driscoll, David I.; Shoykhet, Boris A.

    2004-11-02

    A system for cooling a superconductor device includes a cryocooler located in a stationary reference frame and a closed circulation system external to the cryocooler. The closed circulation system interfaces the stationary reference frame with a rotating reference frame in which the superconductor device is located. A method of cooling a superconductor device includes locating a cryocooler in a stationary reference frame, and transferring heat from a superconductor device located in a rotating reference frame to the cryocooler through a closed circulation system external to the cryocooler. The closed circulation system interfaces the stationary reference frame with the rotating reference frame.

  2. Superconductor rotor cooling system

    DOEpatents

    Gamble, Bruce B.; Sidi-Yekhlef, Ahmed; Schwall, Robert E.; Driscoll, David I.; Shoykhet, Boris A.

    2002-01-01

    A system for cooling a superconductor device includes a cryocooler located in a stationary reference frame and a closed circulation system external to the cryocooler. The closed circulation system interfaces the stationary reference frame with a rotating reference frame in which the superconductor device is located. A method of cooling a superconductor device includes locating a cryocooler in a stationary reference frame, and transferring heat from a superconductor device located in a rotating reference frame to the cryocooler through a closed circulation system external to the cryocooler. The closed circulation system interfaces the stationary reference frame with the rotating reference frame.

  3. Design and implementation of magnetically maneuverable capsule endoscope system with direction reference for image navigation.

    PubMed

    Sun, Zhen-Jun; Ye, Bo; Sun, Yi; Zhang, Hong-Hai; Liu, Sheng

    2014-07-01

    This article describes a novel magnetically maneuverable capsule endoscope system with direction reference for image navigation. This direction reference was employed by utilizing a specific magnet configuration between a pair of external permanent magnets and a magnetic shell coated on the external capsule endoscope surface. A pair of customized Cartesian robots, each with only 4 degrees of freedom, was built to hold the external permanent magnets as their end-effectors. These robots, together with their external permanent magnets, were placed on two opposite sides of a "patient bed." Because of the optimized configuration based on magnetic analysis between the external permanent magnets and the magnetic shell, a simplified control strategy was proposed, and only two parameters, yaw step angle and moving step, were necessary for the employed robotic system. Step-by-step experiments demonstrated that the proposed system is capable of magnetically maneuvering the capsule endoscope while providing direction reference for image navigation. © IMechE 2014.

  4. Conventional external beam radiotherapy for central nervous system malignancies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Halperin, E.C.; Burger, P.C.

    1985-11-01

    Fractionated external beam photon radiotherapy is an important component of the clinical management of malignant disease of the central nervous system. The practicing neurologist or neurosurgeon frequently relies on the consultative and treatment skills of a radiotherapist. This article provides a review for the nonradiotherapist of the place of conventional external beam radiotherapy in neuro-oncology. 23 references.

  5. On the Effectiveness of a Neural Network for Adaptive External Pacing.

    ERIC Educational Resources Information Center

    Montazemi, Ali R.; Wang, Feng

    1995-01-01

    Proposes a neural network model for an intelligent tutoring system featuring adaptive external control of student pacing. An experiment was conducted, and students using adaptive external pacing experienced improved mastery learning and increased motivation for time management. Contains 66 references. (JKP)

  6. The Effectiveness of the Higher Education Quality Assessment System: Problems and Countermeasures in China

    ERIC Educational Resources Information Center

    Guangli, Zhou

    2016-01-01

    The effectiveness of the higher education quality assessment system is essentially a matter of policy evaluation. On the macro level, such a system refers to external quality assessment, which includes government evaluation, quality certification, and university rankings. Depending on the degree of government intervention, the external quality…

  7. Robust Vision-Based Pose Estimation Algorithm for AN Uav with Known Gravity Vector

    NASA Astrophysics Data System (ADS)

    Kniaz, V. V.

    2016-06-01

    Accurate estimation of camera external orientation with respect to a known object is one of the central problems in photogrammetry and computer vision. In recent years this problem is gaining an increasing attention in the field of UAV autonomous flight. Such application requires a real-time performance and robustness of the external orientation estimation algorithm. The accuracy of the solution is strongly dependent on the number of reference points visible on the given image. The problem only has an analytical solution if 3 or more reference points are visible. However, in limited visibility conditions it is often needed to perform external orientation with only 2 visible reference points. In such case the solution could be found if the gravity vector direction in the camera coordinate system is known. A number of algorithms for external orientation estimation for the case of 2 known reference points and a gravity vector were developed to date. Most of these algorithms provide analytical solution in the form of polynomial equation that is subject to large errors in the case of complex reference points configurations. This paper is focused on the development of a new computationally effective and robust algorithm for external orientation based on positions of 2 known reference points and a gravity vector. The algorithm implementation for guidance of a Parrot AR.Drone 2.0 micro-UAV is discussed. The experimental evaluation of the algorithm proved its computational efficiency and robustness against errors in reference points positions and complex configurations.

  8. Real-time sonoelastography using an external reference material: test-retest reliability of healthy Achilles tendons.

    PubMed

    Schneebeli, Alessandro; Del Grande, Filippo; Vincenzo, Gabriele; Cescon, Corrado; Clijsen, Ron; Biordi, Fulvio; Barbero, Marco

    2016-08-01

    To establish the test-retest reliability of sonoelastography (SE) on healthy Achilles tendons in contracted and relaxed states using an external reference system. Forty-eight Achilles tendons from 24 healthy volunteers were assessed using ultrasound and real-time SE with an external reference material. Tendons were analyzed under relaxed and contracted conditions. Strain ratios between the tendons and the reference material were calculated. The intraclass correlation coefficient (ICC2.k) and Bland-Altman plot were used to assess test-retest reliability. The reliability of SE measurements under relaxed conditions ranged from high to very high, with an ICC2.k of 0.84 (95 % CI: 0.64-0.92) for reference material, 0.91 (95 % CI: 0.83-0.95) for Achilles tendons and 0.95 (95 % CI: 0.91-0.97) for Kager fat pads (KFP). The ICC2.k value for skin was 0.30 (95 % CI: -0.26 to 0.61). Reliability for measurements in the contracted state ranged from high to very high, with an ICC2.k of 0.93 (95 % CI: 0.87-0.96) for reference material, 0.72 (95 % CI: 0.50-0.84) for skin, 0.93 (95 % CI: 0.87-0.96) for Achilles tendons, and 0.81 (95 % CI: 0.66-0.89) for KFP. Reliability of the strain ratio (tendon/reference) under relaxed conditions was high with an ICC2.k of 0.87 (95 % CI: 0.75-0.93), and in the contracted state, it was very high with an ICC2.k of 0.94 (95 % CI: 0.90-0.97). Sonoelastography using an external reference material is a reliable and simple technique for the assessment of the elasticity of healthy Achilles tendons. The use of an external material as a reference, along with strain ratios, could provide a quantitative measure of elasticity.

  9. On the Essence of Space

    NASA Astrophysics Data System (ADS)

    Kalanov, Temur Z.

    2003-04-01

    A new theory of space is suggested. It represents the new point of view which has arisen from the critical analysis of the foundations of physics (in particular the theory of relativity and quantum mechanics), mathematics, cosmology and philosophy. The main idea following from the analysis is that the concept of movement represents a key to understanding of the essence of space. The starting-point of the theory is represented by the following philosophical (dialectical materialistic) principles. (a) The principle of the materiality (of the objective reality) of the Nature: the Nature (the Universe) is a system (a set) of material objects (particles, bodies, fields); each object has properties, features, and the properties, the features are inseparable characteristics of material object and belong only to material object. (b) The principle of the existence of material object: an object exists as the objective reality, and movement is a form of existence of object. (c) The principle (definition) of movement of object: the movement is change (i.e. transition of some states into others) in general; the movement determines a direction, and direction characterizes the movement. (d) The principle of existence of time: the time exists as the parameter of the system of reference. These principles lead to the following statements expressing the essence of space. (1) There is no space in general, and there exist space only as a form of existence of the properties and features of the object. It means that the space is a set of the measures of the object (the measure is the philosophical category meaning unity of the qualitative and quantitative determinacy of the object). In other words, the space of the object is a set of the states of the object. (2) The states of the object are manifested only in a system of reference. The main informational property of the unitary system researched physical object + system of reference is that the system of reference determines (measures, calculates) the parameters of the subsystem researched physical object (for example, the coordinates of the object M); the parameters characterize the system of reference (for example, the system of coordinates S). (3) Each parameter of the object is its measure. Total number of the mutually independent parameters of the object is called dimension of the space of the object. (4) The set of numerical values (i.e. the range, the spectrum) of each parameter is the subspace of the object. (The coordinate space, the momentum space and the energy space are examples of the subspaces of the object). (5) The set of the parameters of the object is divided into two non intersecting (opposite) classes: the class of the internal parameters and the class of the non internal (i.e. external) parameters. The class of the external parameters is divided into two non intersecting (opposite) subclasses: the subclass of the absolute parameters (characterizing the form, the sizes of the object) and the subclass of the non absolute (relative) parameters (characterizing the position, the coordinates of the object). (6) Set of the external parameters forms the external space of object. It is called geometrical space of object. (7) Since a macroscopic object has three mutually independent sizes, the dimension of its external absolute space is equal to three. Consequently, the dimension of its external relative space is also equal to three. Thus, the total dimension of the external space of the macroscopic object is equal to six. (8) In general case, the external absolute space (i.e. the form, the sizes) and the external relative space (i.e. the position, the coordinates) of any object are mutually dependent because of influence of a medium. The geometrical space of such object is called non Euclidean space. If the external absolute space and the external relative space of some object are mutually independent, then the external relative space of such object is the homogeneous and isotropic geometrical space. It is called Euclidean space of the object. Consequences: (i) the question of true geometry of the Universe is incorrect; (ii) the theory of relativity has no physical meaning.

  10. Synchronization of an optomechanical system to an external drive

    NASA Astrophysics Data System (ADS)

    Amitai, Ehud; Lörch, Niels; Nunnenkamp, Andreas; Walter, Stefan; Bruder, Christoph

    2017-05-01

    Optomechanical systems driven by an effective blue-detuned laser can exhibit self-sustained oscillations of the mechanical oscillator. These self-oscillations are a prerequisite for the observation of synchronization. Here, we study the synchronization of the mechanical oscillations to an external reference drive. We study two cases of reference drives: (1) an additional laser applied to the optical cavity; (2) a mechanical drive applied directly to the mechanical oscillator. Starting from a master equation description, we derive a microscopic Adler equation for both cases, valid in the classical regime in which the quantum shot noise of the mechanical self-oscillator does not play a role. Furthermore, we numerically show that, in both cases, synchronization arises also in the quantum regime. The optomechanical system is therefore a good candidate for the study of quantum synchronization.

  11. An analytic-numerical method for the construction of the reference law of operation for a class of mechanical controlled systems

    NASA Astrophysics Data System (ADS)

    Mizhidon, A. D.; Mizhidon, K. A.

    2017-04-01

    An analytic-numerical method for the construction of a reference law of operation for a class of dynamic systems describing vibrations in controlled mechanical systems is proposed. By the reference law of operation of a system, we mean a law of the system motion that satisfies all the requirements for the quality and design features of the system under permanent external disturbances. As disturbances, we consider polyharmonic functions with known amplitudes and frequencies of the harmonics but unknown initial phases. For constructing the reference law of motion, an auxiliary optimal control problem is solved in which the cost function depends on a weighting coefficient. The choice of the weighting coefficient ensures the design of the reference law. Theoretical foundations of the proposed method are given.

  12. Reference manual for a Requirements Specification Language (RSL), version 2.0

    NASA Technical Reports Server (NTRS)

    Fisher, Gene L.; Cohen, Gerald C.

    1993-01-01

    This report is a Reference Manual for a general-purpose Requirements Specification Language, RSL. The purpose of RSL is to specify precisely the external structure of a mechanized system and to define requirements that the system must meet. A system can be comprised of a mixture of hardware, software, and human processing elements. RSL is a hybrid of features found in several popular requirements specification languages and includes constructs for formal mathematical specification.

  13. Redundancy management of electrohydraulic servoactuators by mathematical model referencing

    NASA Technical Reports Server (NTRS)

    Campbell, R. A.

    1971-01-01

    A description of a mathematical model reference system is presented which provides redundancy management for an electrohydraulic servoactuator. The mathematical model includes a compensation network that calculates reference parameter perturbations induced by external disturbance forces. This is accomplished by using the measured pressure differential data taken from the physical system. This technique was experimentally verified by tests performed using the H-1 engine thrust vector control system for Saturn IB. The results of these tests are included in this report. It was concluded that this technique improves the tracking accuracy of the model reference system to the extent that redundancy management of electrohydraulic servosystems may be performed using this method.

  14. Experiences From Creating the Guide to the Systems Engineering Body of Knowledge (SEBoK) v. 1.0

    DTIC Science & Technology

    2013-03-01

    00-00-2013 to 00-00-2013 4. TITLE AND SUBTITLE Experiences From Creating the Guide to the Systems Engineering Body of Knowledge (SEBoK) v. 1.0 5a...external sources, was not easy to achieve. SE Literature: The most comprehensive source of SE knowledge today is the Systems Engineering Handbook [3...recommended for further reading - SEBoK v. 1.0 includes 224 primary references; and (3) Additional references include other related literature that are good

  15. Environmental Scanning in Educational Planning: Establishing a Strategic Trend Information System.

    ERIC Educational Resources Information Center

    Morrison, James L.

    The systematic evaluation of the macroenvironment is sometimes referred to as a strategic trend information system. Strategic trend intelligence systems are highly developed, systematic intelligence programs that focus on trends and events in the external environment and provide institutions with knowledge to reduce areas of uncertainty and with…

  16. Automotive Stirling Engine Mod 1 Design Review, Volume 1

    NASA Technical Reports Server (NTRS)

    1982-01-01

    Risk assessment, safety analysis of the automotive stirling engine (ASE) mod I, design criteria and materials properties for the ASE mod I and reference engines, combustion are flower development, and the mod I engine starter motor are discussed. The stirling engine system, external heat system, hot engine system, cold engine system, and engine drive system are also discussed.

  17. The second law of thermodynamics under unitary evolution and external operations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ikeda, Tatsuhiko N., E-mail: ikeda@cat.phys.s.u-tokyo.ac.jp; Physics Department, Boston University, Boston, MA 02215; Sakumichi, Naoyuki

    The von Neumann entropy cannot represent the thermodynamic entropy of equilibrium pure states in isolated quantum systems. The diagonal entropy, which is the Shannon entropy in the energy eigenbasis at each instant of time, is a natural generalization of the von Neumann entropy and applicable to equilibrium pure states. We show that the diagonal entropy is consistent with the second law of thermodynamics upon arbitrary external unitary operations. In terms of the diagonal entropy, thermodynamic irreversibility follows from the facts that quantum trajectories under unitary evolution are restricted by the Hamiltonian dynamics and that the external operation is performed withoutmore » reference to the microscopic state of the system.« less

  18. Implementation of standardization in clinical practice: not always an easy task.

    PubMed

    Panteghini, Mauro

    2012-02-29

    As soon as a new reference measurement system is adopted, clinical validation of correctly calibrated commercial methods should take place. Tracing back the calibration of routine assays to a reference system can actually modify the relation of analyte results to existing reference intervals and decision limits and this may invalidate some of the clinical decision-making criteria currently used. To maintain the accumulated clinical experience, the quantitative relationship to the previous calibration system should be established and, if necessary, the clinical decision-making criteria should be adjusted accordingly. The implementation of standardization should take place in a concerted action of laboratorians, manufacturers, external quality assessment scheme organizers and clinicians. Dedicated meetings with manufacturers should be organized to discuss the process of assay recalibration and studies should be performed to obtain convincing evidence that the standardization works, improving result comparability. Another important issue relates to the surveillance of the performance of standardized assays through the organization of appropriate analytical internal and external quality controls. Last but not least, uncertainty of measurement that fits for this purpose must be defined across the entire traceability chain, starting with the available reference materials, extending through the manufacturers and their processes for assignment of calibrator values and ultimately to the final result reported to clinicians by laboratories.

  19. A Damping Grid Strapdown Inertial Navigation System Based on a Kalman Filter for Ships in Polar Regions.

    PubMed

    Huang, Weiquan; Fang, Tao; Luo, Li; Zhao, Lin; Che, Fengzhu

    2017-07-03

    The grid strapdown inertial navigation system (SINS) used in polar navigation also includes three kinds of periodic oscillation errors as common SINS are based on a geographic coordinate system. Aiming ships which have the external information to conduct a system reset regularly, suppressing the Schuler periodic oscillation is an effective way to enhance navigation accuracy. The Kalman filter based on the grid SINS error model which applies to the ship is established in this paper. The errors of grid-level attitude angles can be accurately estimated when the external velocity contains constant error, and then correcting the errors of the grid-level attitude angles through feedback correction can effectively dampen the Schuler periodic oscillation. The simulation results show that with the aid of external reference velocity, the proposed external level damping algorithm based on the Kalman filter can suppress the Schuler periodic oscillation effectively. Compared with the traditional external level damping algorithm based on the damping network, the algorithm proposed in this paper can reduce the overshoot errors when the state of grid SINS is switched from the non-damping state to the damping state, and this effectively improves the navigation accuracy of the system.

  20. Intelligent control of a multi-degree-of freedom reaction compensating platform system using fuzzy logic

    NASA Technical Reports Server (NTRS)

    Choi, Benjamin B.; Lawrence, Charles; Lin, Yueh-Jaw

    1994-01-01

    This paper presents the development of a general-purpose fuzzy logic (FL) control methodology for isolating the external vibratory disturbances of space-based devices. According to the desired performance specifications, a full investigation regarding the development of an FL controller was done using different scenarios, such as variances of passive reaction-compensating components and external disturbance load. It was shown that the proposed FL controller is robust in that the FL-controlled system closely follows the prespecified ideal reference model. The comparative study also reveals that the FL-controlled system achieves significant improvement in reducing vibrations over passive systems.

  1. The Reciprocal Internal/External Frame of Reference Model: An Integration of Models of Relations between Academic Achievement and Self-Concept

    ERIC Educational Resources Information Center

    Moller, Jens; Retelsdorf, Jan; Koller, Olaf; Marsh, Herb W.

    2011-01-01

    The reciprocal internal/external frame of reference model (RI/EM) combines the internal/external frame of reference model and the reciprocal effects model. The RI/EM predicts positive effects of mathematics and verbal achievement and academic self-concepts (ASC) on subsequent mathematics and verbal achievements and ASCs within domains and negative…

  2. An automatic tracking system for phase-noise measurement.

    PubMed

    Yuen, Chung Ming; Tsang, Kim Fung

    2005-05-01

    A low cost, automatic tracking system for phase noise measurement has been implemented successfully. The tracking system is accomplished by applying a charge pump phase-locked loop as an external reference source to a digital spectrum analyzer. Measurement of a 2.5 GHz, free-running, voltage-controlled oscillator demonstrated the tracking accuracy, thus verifying the feasibility of the system.

  3. Automotive Stirling reference engine design report

    NASA Technical Reports Server (NTRS)

    1981-01-01

    The reference Stirling engine system is described which provides the best possible fuel economy while meeting or exceeding all other program objectives. The system was designed to meet the requirements of a 1984 Pontiac Phoenix (X-body). This design utilizes all new technology that can reasonably be expected to be developed by 1984 and that is judged to provide significant improvement, relative to development risk and cost. Topics covered include: (1) external heat system; (2) hot engine system; (3) cold engine system; (4) engine drive system; (5) power control system and auxiliaries; (6) engine instalation; (7) optimization and vehicle simulation; (8) engine materials; and (9) production cost analysis.

  4. The Nature of the University

    ERIC Educational Resources Information Center

    Lenartowicz, Marta

    2015-01-01

    Higher education research frequently refers to the complex external conditions that give our old-fashioned universities a good reason to change. The underlying theoretical assumption of such framing is that organizations are open systems. This paper presents an alternative view, derived from the theory of social systems autopoiesis. It proposes…

  5. Differential School Contextual Effects for Math and English: Integrating the Big-Fish-Little-Pond Effect and the Internal/External Frame of Reference

    ERIC Educational Resources Information Center

    Parker, Philip D.; Marsh, Herbert W.; Ludtke, Oliver; Trautwein, Ulrich

    2013-01-01

    The internal/external frame of reference and the big-fish-little-pond effect are two major models of academic self-concept formation which have considerable theoretical and empirical support. Integrating the domain specific and compensatory processes of the internal/external frame of reference model with the big-fish-little-pond effect suggests a…

  6. On-Line Tracking Controller for Brushless DC Motor Drives Using Artificial Neural Networks

    NASA Technical Reports Server (NTRS)

    Rubaai, Ahmed

    1996-01-01

    A real-time control architecture is developed for time-varying nonlinear brushless dc motors operating in a high performance drives environment. The developed control architecture possesses the capabilities of simultaneous on-line identification and control. The dynamics of the motor are modeled on-line and controlled using an artificial neural network, as the system runs. The control architecture combines the experience and dependability of adaptive tracking systems with potential and promise of the neural computing technology. The sensitivity of real-time controller to parametric changes that occur during training is investigated. Such changes are usually manifested by rapid changes in the load of the brushless motor drives. This sudden change in the external load is simulated for the sigmoidal and sinusoidal reference tracks. The ability of the neuro-controller to maintain reasonable tracking accuracy in the presence of external noise is also verified for a number of desired reference trajectories.

  7. Three dimensional nozzle-exhaust flow field analysis by a reference plane technique.

    NASA Technical Reports Server (NTRS)

    Dash, S. M.; Del Guidice, P. D.

    1972-01-01

    A numerical method based on reference plane characteristics has been developed for the calculation of highly complex supersonic nozzle-exhaust flow fields. The difference equations have been developed for three coordinate systems. Local reference plane orientations are employed using the three coordinate systems concurrently thus catering to a wide class of flow geometries. Discontinuities such as the underexpansion shock and contact surfaces are computed explicitly for nonuniform vehicle external flows. The nozzles considered may have irregular cross-sections with swept throats and may be stacked in modules using the vehicle undersurface for additional expansion. Results are presented for several nozzle configurations.

  8. Pitch Systems and Curwen Hand Signs: A Review of Literature

    ERIC Educational Resources Information Center

    Frey-Clark, Marta

    2017-01-01

    Learning to sing from notation is a complex task, and accurately performing pitches without an external reference can be particularly challenging. As such, the use of mnemonic devices to reinforce tonal relationships is a long-standing practice among musicians. Chief among these mnemonic devices are pitch syllable systems and Curwen hand signs.…

  9. Regulating External Threats in the Cigarette Industry.

    ERIC Educational Resources Information Center

    Dunbar, Roger L.; Wasilewski, Nikolai

    1985-01-01

    Research was conducted to evaluate how organizationsl systems that are publicly accused of wrongdoing attempt to justify themselves. The pattern of events surrounding smoking and health was examined over a 30-year period. Includes four figures, two tables, and references. (MD)

  10. [Mental health of adolescents in the juvenile detention system: the relationship between the system's staff and external mental health services].

    PubMed

    Ribeiro, Débora Stephanie; Ribeiro, Fernanda Mendes Lages; Deslandes, Suely Ferreira

    2018-03-12

    The aim of this article is to analyze how professionals in the mental health teams of the juvenile detention system in Rio de Janeiro, Brazil, perceive the relations with the external Network of Psychosocial Care in dealing with mental health issues in adolescents serving time in juvenile detention centers. Nine interviews were held with mental health professionals in the system, and the results were presented with Fairclough's critical discourse analysis as the reference. The results were organized in three parts: the relationship between the juvenile detention system's mental health teams and the external services, difficulties experienced by the teams from the detention centers and the external network's services, and prospects and proposals. The logic of the arguments' development showed that the weakness in the agreements between administrators of the Brazilian Unified National Health System and the juvenile detention system has a daily impact on mental health activities conducted by the centers' teams. This scenario is aggravated by other structural problems such as lack of transportation and personnel to accompany adolescents on extramural appointments, and resistance on the part of professionals both inside and outside the detention centers. The study showed that both the adolescents and professionals were isolated in relation to mental health activities and policies.

  11. On the establishment and maintenance of a modern conventional terrestrial reference system

    NASA Technical Reports Server (NTRS)

    Bock, Y.; Zhu, S. Y.

    1982-01-01

    The frame of the Conventional Terrestrial Reference System (CTS) is defined by an adopted set of coordinates, at a fundamental epoxh, of a global network of stations which contribute the vertices of a fundamental polyhedron. A method to estimate this set of coordinates using a combination of modern three dimensional geodetic systems is presented. Once established, the function of the CTS is twofold. The first is to monitor the external (or global) motions of the polyhedron with respect to the frame of a Conventional Inertial Reference System, i.e., those motions common to all stations. The second is to monitor the internal motions (or deformations) of the polyhedron, i.e., those motions that are not common to all stations. Two possible estimators for use in earth deformation analysis are given and their statistical and physical properties are described.

  12. Dynamic response of a Mach 2.5 axisymmetric inlet and turbojet engine with a poppet-value controlled inlet stability bypass system when subjected to internal and external airflow transients

    NASA Technical Reports Server (NTRS)

    Sanders, B. W.

    1980-01-01

    The throat of a Mach 2.5 inlet that was attached to a turbojet engine was fitted with a poppet-valve-controlled stability bypass system that was designed to provide a large, stable airflow range. Propulsion system response and stability bypass performance were determined for several transient airflow disturbances, both internal and external. Internal airflow disturbances included reductions in overboard bypass airflow, power lever angle, and primary-nozzle area as well as compressor stall. For reference, data are also included for a conventional, fixed-exit bleed system. The poppet valves greatly increased inlet stability and had no adverse effects on propulsion system performance. Limited unstarted-inlet bleed performance data are presented.

  13. Non-invasive Renal Denervation: Update on External Ultrasound Approaches.

    PubMed

    Schmieder, Roland E; Ott, Christian; Bramlage, Peter

    2016-06-01

    In the last decade, intravenous renal denervation (RDN) has emerged as an alternative to pharmacological treatment in patients with resistant hypertension, but currently involves an invasive and technically challenging procedure. The Surround Sound™ system utilises externally delivered ultrasound to achieve RDN using a completely non-invasive, automated real-time tracking system coupled with a therapeutic delivery module thereby addressing these limitations. A brief history, technical overview and summary of preclinical and clinical studies of the KonaMedical Surround Sound™ system are presented. A literature search using the terms "renal denervation", "resistant hypertension" and "external ultrasound" was performed using PubMed, and references retrieved were selected based on relevancy and year of publication (date range 1991-2015). The Surround Sound™ system appears to be a promising approach to RDN which eliminates several of the factors currently limiting the intravenous approach. So far, it has demonstrated efficacy for reducing blood pressure in resistant hypertension patients with minimal adverse effects. Several double-blind, sham-controlled clinical trials are currently underway to confirm the validity of these findings.

  14. Baseline Assessment of 25-Hydroxyvitamin D Reference Material and Proficiency Testing/External Quality Assurance Material Commutability: A Vitamin D Standardization Program Study.

    PubMed

    Phinney, Karen W; Sempos, Christopher T; Tai, Susan S-C; Camara, Johanna E; Wise, Stephen A; Eckfeldt, John H; Hoofnagle, Andrew N; Carter, Graham D; Jones, Julia; Myers, Gary L; Durazo-Arvizu, Ramon; Miller, W Greg; Bachmann, Lorin M; Young, Ian S; Pettit, Juanita; Caldwell, Grahame; Liu, Andrew; Brooks, Stephen P J; Sarafin, Kurtis; Thamm, Michael; Mensink, Gert B M; Busch, Markus; Rabenberg, Martina; Cashman, Kevin D; Kiely, Mairead; Galvin, Karen; Zhang, Joy Y; Kinsella, Michael; Oh, Kyungwon; Lee, Sun-Wha; Jung, Chae L; Cox, Lorna; Goldberg, Gail; Guberg, Kate; Meadows, Sarah; Prentice, Ann; Tian, Lu; Brannon, Patsy M; Lucas, Robyn M; Crump, Peter M; Cavalier, Etienne; Merkel, Joyce; Betz, Joseph M

    2017-09-01

    The Vitamin D Standardization Program (VDSP) coordinated a study in 2012 to assess the commutability of reference materials and proficiency testing/external quality assurance materials for total 25-hydroxyvitamin D [25(OH)D] in human serum, the primary indicator of vitamin D status. A set of 50 single-donor serum samples as well as 17 reference and proficiency testing/external quality assessment materials were analyzed by participating laboratories that used either immunoassay or LC-MS methods for total 25(OH)D. The commutability test materials included National Institute of Standards and Technology Standard Reference Material 972a Vitamin D Metabolites in Human Serum as well as materials from the College of American Pathologists and the Vitamin D External Quality Assessment Scheme. Study protocols and data analysis procedures were in accordance with Clinical and Laboratory Standards Institute guidelines. The majority of the test materials were found to be commutable with the methods used in this commutability study. These results provide guidance for laboratories needing to choose appropriate reference materials and select proficiency or external quality assessment programs and will serve as a foundation for additional VDSP studies.

  15. Infrared non-destructive evaluation method and apparatus

    DOEpatents

    Baleine, Erwan; Erwan, James F; Lee, Ching-Pang; Stinelli, Stephanie

    2014-10-21

    A method of nondestructive evaluation and related system. The method includes arranging a test piece (14) having an internal passage (18) and an external surface (15) and a thermal calibrator (12) within a field of view (42) of an infrared sensor (44); generating a flow (16) of fluid characterized by a fluid temperature; exposing the test piece internal passage (18) and the thermal calibrator (12) to fluid from the flow (16); capturing infrared emission information of the test piece external surface (15) and of the thermal calibrator (12) simultaneously using the infrared sensor (44), wherein the test piece infrared emission information includes emission intensity information, and wherein the thermal calibrator infrared emission information includes a reference emission intensity associated with the fluid temperature; and normalizing the test piece emission intensity information against the reference emission intensity.

  16. "Accordion" deformity of a tortuous external iliac artery after stent-graft placement.

    PubMed

    Quinn, S F; Kim, J; Sheley, R C; Frankhouse, J H

    2001-02-01

    To identify a complication of endograft deployment in aneurysmal iliac arteries. A 71-year-old man was referred for endovascular treatment of a 60-mm-diameter right common iliac artery aneurysm; however, deployment of a homemade covered stent (Palmaz-Schatz and polytetrafluoroethylene) induced shortening of the tortuous external iliac artery, causing an "accordion" deformity. The anomaly proved difficult to treat with serial Wallstent deployment, because the convolution tightened and migrated caudally with each stent deployed, threatening outflow. Finally, after 3 Wallstents were implanted, the contour of the external iliac artery was straight, and flow was unimpeded. However, 3 weeks later, the external iliac artery had recoiled to its original redundant appearance, but flow remained satisfactory. The aneurysm remains excluded, with satisfactory distal flow after 24 months. Implanting endografts in redundant, tortuous arterial segments may prove problematic, since induced straightening by the device precipitates kinking in the redundant system. Although treatment may be required in some situations, the vessels may return to a noncompressed state by removing the delivery system and guidewire.

  17. Application of Energy Integration Techniques to the Design of Advanced Life Support Systems

    NASA Technical Reports Server (NTRS)

    Levri, Julie; Finn, Cory

    2000-01-01

    Exchanging heat between hot and cold streams within an advanced life support system can save energy. This savings will reduce the equivalent system mass (ESM) of the system. Different system configurations are examined under steady-state conditions for various percentages of food growth and waste treatment. The scenarios investigated represent possible design options for a Mars reference mission. Reference mission definitions are drawn from the ALSS Modeling and Analysis Reference Missions Document, which includes definitions for space station evolution, Mars landers, and a Mars base. For each scenario, streams requiring heating or cooling are identified and characterized by mass flow, supply and target temperatures and heat capacities. The Pinch Technique is applied to identify good matches for energy exchange between the hot and cold streams and to calculate the minimum external heating and cooling requirements for the system. For each pair of hot and cold streams that are matched, there will be a reduction in the amount of external heating and cooling required, and the original heating and cooling equipment will be replaced with a heat exchanger. The net cost savings can be either positive or negative for each stream pairing, and the priority for implementing each pairing can be ranked according to its potential cost savings. Using the Pinch technique, a complete system heat exchange network is developed and heat exchangers are sized to allow for calculation of ESM. The energy-integrated design typically has a lower total ESM than the original design with no energy integration. A comparison of ESM savings in each of the scenarios is made to direct future Pinch Analysis efforts.

  18. Sulfate and sulfide sulfur isotopes (δ34S and δ33S) measured by solution and laser ablation MC-ICP-MS: An enhanced approach using external correction

    USGS Publications Warehouse

    Pribil, Michael; Ridley, William I.; Emsbo, Poul

    2015-01-01

    Isotope ratio measurements using a multi-collector inductively coupled plasma mass spectrometer (MC-ICP-MS) commonly use standard-sample bracketing with a single isotope standard for mass bias correction for elements with narrow-range isotope systems measured by MC-ICP-MS, e.g. Cu, Fe, Zn, and Hg. However, sulfur (S) isotopic composition (δ34S) in nature can range from at least − 40 to + 40‰, potentially exceeding the ability of standard-sample bracketing using a single sulfur isotope standard to accurately correct for mass bias. Isotopic fractionation via solution and laser ablation introduction was determined during sulfate sulfur (Ssulfate) isotope measurements. An external isotope calibration curve was constructed using in-house and National Institute of Standards and Technology (NIST) Ssulfate isotope reference materials (RM) in an attempt to correct for the difference. The ability of external isotope correction for Ssulfate isotope measurements was evaluated by analyzing NIST and United States Geological Survey (USGS) Ssulfate isotope reference materials as unknowns. Differences in δ34Ssulfate between standard-sample bracketing and standard-sample bracketing with external isotope correction for sulfate samples ranged from 0.72‰ to 2.35‰ over a δ34S range of 1.40‰ to 21.17‰. No isotopic differences were observed when analyzing Ssulfide reference materials over a δ34Ssulfide range of − 32.1‰ to 17.3‰ and a δ33S range of − 16.5‰ to 8.9‰ via laser ablation (LA)-MC-ICP-MS. Here, we identify a possible plasma induced fractionation for Ssulfate and describe a new method using external isotope calibration corrections using solution and LA-MC-ICP-MS.

  19. Functional correlates of the lateral and medial entorhinal cortex: objects, path integration and local-global reference frames.

    PubMed

    Knierim, James J; Neunuebel, Joshua P; Deshmukh, Sachin S

    2014-02-05

    The hippocampus receives its major cortical input from the medial entorhinal cortex (MEC) and the lateral entorhinal cortex (LEC). It is commonly believed that the MEC provides spatial input to the hippocampus, whereas the LEC provides non-spatial input. We review new data which suggest that this simple dichotomy between 'where' versus 'what' needs revision. We propose a refinement of this model, which is more complex than the simple spatial-non-spatial dichotomy. MEC is proposed to be involved in path integration computations based on a global frame of reference, primarily using internally generated, self-motion cues and external input about environmental boundaries and scenes; it provides the hippocampus with a coordinate system that underlies the spatial context of an experience. LEC is proposed to process information about individual items and locations based on a local frame of reference, primarily using external sensory input; it provides the hippocampus with information about the content of an experience.

  20. External Quality Assessment Scheme for reference laboratories - review of 8 years' experience.

    PubMed

    Kessler, Anja; Siekmann, Lothar; Weykamp, Cas; Geilenkeuser, Wolf Jochen; Dreazen, Orna; Middle, Jonathan; Schumann, Gerhard

    2013-05-01

    We describe an External Quality Assessment Scheme (EQAS) intended for reference (calibration) laboratories in laboratory medicine and supervised by the Scientific Division of the International Federation of Clinical Chemistry and Laboratory Medicine and the responsible Committee on Traceability in Laboratory Medicine. The official EQAS website, RELA (www.dgkl-rfb.de:81), is open to interested parties. Information on all requirements for participation and results of surveys are published annually. As an additional feature, the identity of every participant in relation to the respective results is disclosed. The results of various groups of measurands (metabolites and substrates, enzymes, electrolytes, glycated hemoglobins, proteins, hormones, thyroid hormones, therapeutic drugs) are discussed in detail. The RELA system supports reference measurement laboratories preparing for accreditation according to ISO 17025 and ISO 15195. Participation in a scheme such as RELA is one of the requirements for listing of the services of a calibration laboratory by the Joint Committee on Traceability in Laboratory Medicine.

  1. Functional correlates of the lateral and medial entorhinal cortex: objects, path integration and local–global reference frames

    PubMed Central

    Knierim, James J.; Neunuebel, Joshua P.; Deshmukh, Sachin S.

    2014-01-01

    The hippocampus receives its major cortical input from the medial entorhinal cortex (MEC) and the lateral entorhinal cortex (LEC). It is commonly believed that the MEC provides spatial input to the hippocampus, whereas the LEC provides non-spatial input. We review new data which suggest that this simple dichotomy between ‘where’ versus ‘what’ needs revision. We propose a refinement of this model, which is more complex than the simple spatial–non-spatial dichotomy. MEC is proposed to be involved in path integration computations based on a global frame of reference, primarily using internally generated, self-motion cues and external input about environmental boundaries and scenes; it provides the hippocampus with a coordinate system that underlies the spatial context of an experience. LEC is proposed to process information about individual items and locations based on a local frame of reference, primarily using external sensory input; it provides the hippocampus with information about the content of an experience. PMID:24366146

  2. The Internal Control System and Control Programs: A Reference Guide

    DTIC Science & Technology

    1990-06-01

    multilocation audits . [Ref. 27:Ch. 8, p. 4] 3. Verification Staqe The actual audit field work occurs during this phase. The audit team provides an entrance...number) ;E, GUO.)P SuB GROUP Internal Control; Internal Control System; Audits ; Reviews; Ccamand Evaluation Program; EconnTy & Efficiency Reviews...general overview of the inter- nal control system and discusses the various external and internal audits , inspections, reviews and investiaative

  3. Comparison of complementary and Kalman filter based data fusion for attitude heading reference system

    NASA Astrophysics Data System (ADS)

    Islam, Tariqul; Islam, Md. Saiful; Shajid-Ul-Mahmud, Md.; Hossam-E-Haider, Md

    2017-12-01

    An Attitude Heading Reference System (AHRS) provides 3D orientation of an aircraft (roll, pitch, and yaw) with instantaneous position and also heading information. For implementation of a low cost AHRS system Micro-electrical-Mechanical system (MEMS) based sensors are used such as accelerometer, gyroscope, and magnetometer. Accelerometers suffer from errors caused by external accelerations that sums to gravity and make accelerometers based rotation inaccurate. Gyroscopes can remove such errors but create drifting problems. So for getting the precise data additionally two very common and well known filters Complementary and Kalman are introduced to the system. In this paper a comparison of system performance using these two filters is shown separately so that one would be able to select filter with better performance for his/her system.

  4. 40 CFR 1065.307 - Linearity verification.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... different flow rates. Use a gravimetric reference measurement (such as a scale, balance, or mass comparator... the gas-division system to divide the span gas with purified air or nitrogen. Select gas divisions... verification for gravimetric PM balances, use external calibration weights that that meet the requirements in...

  5. Performance Indicators (for Kindergartens). (First Edition).

    ERIC Educational Resources Information Center

    Hong Kong Education Dept.

    As part of the 1999 comprehensive review of the education system in Hong Kong, the Education Department introduced a quality assurance framework in local kindergartens. The framework comprises two components: self-evaluation and external monitoring. This guide presents performance indicators for use as evaluation criteria with reference to the…

  6. Demand-type gas supply system for rocket borne thin-window proportional counters

    NASA Technical Reports Server (NTRS)

    Acton, L. W.; Caravalho, R.; Catura, R. C.; Joki, E. G.

    1977-01-01

    A simple closed loop control system has been developed to maintain the gas pressure in thin-window proportional counters during rocket flights. This system permits convenient external control of detector pressure and system flushing rate. The control system is activated at launch with the sealing of a reference volume at the existing system pressure. Inflight control to plus or minus 2 torr at a working pressure of 760 torr has been achieved on six rocket flights.

  7. Use of internal references for assessing CT density measurements of the pelvis as replacement for use of an external phantom.

    PubMed

    Boomsma, Martijn F; Slouwerhof, Inge; van Dalen, Jorn A; Edens, Mireille A; Mueller, Dirk; Milles, Julien; Maas, Mario

    2015-11-01

    The purpose of this research is to study the use of an internal reference standard for fat- and muscle as a replacement for an external reference standard with a phantom. By using a phantomless internal reference standard, Hounsfield unit (HU) measurements of various tissues can potentially be assessed in patients with a CT scan of the pelvis without an added phantom at time of CT acquisition. This paves the way for development of a tool for quantification of the change in tissue density in one patient over time and between patients. This could make every CT scan made without contrast available for research purposes. Fifty patients with unilateral metal-on-metal total hip replacements, scanned together with a calibration reference phantom used in bone mineral density measurements, were included in this study. On computed tomography scans of the pelvis without the use of intravenous iodine contrast, reference values for fat and muscle were measured in the phantom as well as within the patient's body. The conformity between the references was examined with the intra-class correlation coefficient. The mean HU (± SD) of reference values for fat for the internal- and phantom references were -91.5 (±7.0) and -90.9 (±7.8), respectively. For muscle, the mean HU (± SD) for the internal- and phantom references were 59.2 (±6.2) and 60.0 (±7.2), respectively. The intra-class correlation coefficients for fat and muscle were 0.90 and 0.84 respectively and show excellent agreement between the phantom and internal references. Internal references can be used with similar accuracy as references from an external phantom. There is no need to use an external phantom to asses CT density measurements of body tissue.

  8. Gas spectroscopy system with 245 GHz transmitter and receiver in SiGe BiCMOS

    NASA Astrophysics Data System (ADS)

    Schmalz, Klaus; Rothbart, Nick; Borngräber, Johannes; Yilmaz, Selahattin Berk; Kissinger, Dietmar; Hübers, Heinz-Wilhelm

    2017-02-01

    The implementation of an integrated mm-wave transmitter (TX) and receiver (RX) in SiGe BiCMOS or CMOS technology offers a path towards a compact and low-cost system for gas spectroscopy. Previously, we have demonstrated TXs and RXs for spectroscopy at 238 -252 GHz and 495 - 497 GHz using external phase-locked loops (PLLs) with signal generators for the reference frequency ramps. Here, we present a more compact system by using two external fractional-N PLLs allowing frequency ramps for the TX and RX, and for TX with superimposed frequency shift keying (FSK) or reference frequency modulation realized by a direct digital synthesizer (DDS) or an arbitrary waveform generator. The 1.9 m folded gas absorption cell, the vacuum pumps, as well as the TX and RX are placed on a portable breadboard with dimensions of 75 cm x 45 cm. The system performance is evaluated by high-resolution absorption spectra of gaseous methanol at 13 Pa for 241 - 242 GHz. The 2f (second harmonic) content of the absorption spectrum of the methanol was obtained by detecting the IF power of RX using a diode power sensor connected to a lock-in amplifier. The reference frequency modulation reveals a higher SNR (signal-noise-ratio) of 98 within 32 s acquisition compared to 66 for FSK. The setup allows for jumping to preselected frequency regions according to the spectral signature thus reducing the acquisition time by up to one order of magnitude.

  9. Smart and precise alignment of optical systems

    NASA Astrophysics Data System (ADS)

    Langehanenberg, Patrik; Heinisch, Josef; Stickler, Daniel

    2013-09-01

    For the assembly of any kind of optical systems the precise centration of every single element is of particular importance. Classically the precise alignment of optical components is based on the precise centering of all components to an external axis (usually a high-precision rotary spindle axis). Main drawback of this timeconsuming process is that it is significantly sensitive to misalignments of the reference (e.g. the housing) axis. In order to facilitate process in this contribution we present a novel alignment strategy for the TRIOPTICS OptiCentric® instrument family that directly aligns two elements with respect to each other by measuring the first element's axis and using this axis as alignment reference without the detour of considering an external reference. According to the optical design any axis in the system can be chosen as target axis. In case of the alignment to a barrel this axis is measured by using a distance sensor (e.g., the classically used dial indicator). Instead of fine alignment the obtained data is used for the calculation of its orientation within the setup. Alternatively, the axis of an optical element (single lens or group of lenses) whose orientation is measured with the standard OptiCentric MultiLens concept can be used as a reference. In the instrument's software the decentering of the adjusting element to the calculated axis is displayed in realtime and indicated by a target mark that can be used for the manual alignment. In addition, the obtained information can also be applied for active and fully automated alignment of lens assemblies with the help of motorized actuators.

  10. Graphical Language Games: Interactional Constraints on Representational Form

    ERIC Educational Resources Information Center

    Healey, Patrick G. T.; Swoboda, Nik; Umata, Ichiro; King, James

    2007-01-01

    The emergence of shared symbol systems is considered to be a pivotal moment in human evolution and human development. These changes are normally explained by reference to changes in people's internal cognitive processes. We present 2 experiments which provide evidence that changes in the external, collaborative processes that people use to…

  11. Personal resources and support when regaining the ability to work: an interview study with Exhaustion Disorder patients.

    PubMed

    Norlund, Sofia; Fjellman-Wiklund, Anncristine; Nordin, Maria; Stenlund, Therese; Ahlgren, Christina

    2013-06-01

    The aim of the study was to explore experiences and thoughts in the process of returning to work in employed patients with Exhaustion Disorder. Twelve patients with Exhaustion Disorder (burnout) who had been referred to a Stress Rehabilitation Clinic were interviewed. All patients were employed but a majority was on full or part-time sick leave. Grounded Theory was used as the qualitative method. A core category, regaining the ability to work, was developed. Alongside, two categories, internal resources and the external support system, were experienced as being important to the process. The internal resources were expressed through three key features (sub-categories), perceived validation, insights and adaptive coping abilities. The external support system was diverse and described by the sub-categories practical/structural and/or emotional support. Four external support actors were identified; the workplace, health care, the Social Insurance Agency, and the union. The supervisor was described as the most important external actor. Internal and external resources are intertwined in the process of regaining the ability to work. The internal resources and external support can directly increase the probability to regain the ability to work. Moreover, these resources can affect each other and thus indirectly have an effect on the process.

  12. Integrated Air and Missile Defense (IAMD)

    DTIC Science & Technology

    2015-12-01

    equal to or greater than the effectiveness levels of fielded TBM and CM/ABT defense systems. Common Command and Control The Army IAMD SoS common C2...externally developed sensors and shooters to provide an effective IAMD capability. The IAMD program will allow transformation to a network-centric system of...systems capability, also referred to as "Plug and Fight", that integrates all Air and Missile Defense (AMD) sensors, weapons, and mission control

  13. A method of camera calibration in the measurement process with reference mark for approaching observation space target

    NASA Astrophysics Data System (ADS)

    Zhang, Hua; Zeng, Luan

    2017-11-01

    Binocular stereoscopic vision can be used for space-based space targets near observation. In order to solve the problem that the traditional binocular vision system cannot work normally after interference, an online calibration method of binocular stereo measuring camera with self-reference is proposed. The method uses an auxiliary optical imaging device to insert the image of the standard reference object into the edge of the main optical path and image with the target on the same focal plane, which is equivalent to a standard reference in the binocular imaging optical system; When the position of the system and the imaging device parameters are disturbed, the image of the standard reference will change accordingly in the imaging plane, and the position of the standard reference object does not change. The camera's external parameters can be re-calibrated by the visual relationship of the standard reference object. The experimental results show that the maximum mean square error of the same object can be reduced from the original 72.88mm to 1.65mm when the right camera is deflected by 0.4 degrees and the left camera is high and low with 0.2° rotation. This method can realize the online calibration of binocular stereoscopic vision measurement system, which can effectively improve the anti - jamming ability of the system.

  14. Doppler ultrasound-based measurement of tendon velocity and displacement for application toward detecting user-intended motion.

    PubMed

    Stegman, Kelly J; Park, Edward J; Dechev, Nikolai

    2012-07-01

    The motivation of this research is to non-invasively monitor the wrist tendon's displacement and velocity, for purposes of controlling a prosthetic device. This feasibility study aims to determine if the proposed technique using Doppler ultrasound is able to accurately estimate the tendon's instantaneous velocity and displacement. This study is conducted with a tendon mimicking experiment consisting of two different materials: a commercial ultrasound scanner, and a reference linear motion stage set-up. Audio-based output signals are acquired from the ultrasound scanner, and are processed with our proposed Fourier technique to obtain the tendon's velocity and displacement estimates. We then compare our estimates to an external reference system, and also to the ultrasound scanner's own estimates based on its proprietary software. The proposed tendon motion estimation method has been shown to be repeatable, effective and accurate in comparison to the external reference system, and is generally more accurate than the scanner's own estimates. After establishing this feasibility study, future testing will include cadaver-based studies to test the technique on the human arm tendon anatomy, and later on live human test subjects in order to further refine the proposed method for the novel purpose of detecting user-intended tendon motion for controlling wearable prosthetic devices.

  15. Biological Movement and Laws of Physics.

    PubMed

    Latash, Mark L

    2017-07-01

    Living systems may be defined as systems able to organize new, biology-specific, laws of physics and modify their parameters for specific tasks. Examples include the force-length muscle dependence mediated by the stretch reflex, and the control of movements with modification of the spatial referent coordinates for salient performance variables. Low-dimensional sets of referent coordinates at a task level are transformed to higher-dimensional sets at lower hierarchical levels in a way that ensures stability of performance. Stability of actions can be controlled independently of the actions (e.g., anticipatory synergy adjustments). Unintentional actions reflect relaxation processes leading to drifts of corresponding referent coordinates in the absence of changes in external load. Implications of this general framework for movement disorders, motor development, motor skill acquisition, and even philosophy are discussed.

  16. Generation and evaluation of typical meteorological year datasets for greenhouse and external conditions on the Mediterranean coast.

    PubMed

    Fernández, M D; López, J C; Baeza, E; Céspedes, A; Meca, D E; Bailey, B

    2015-08-01

    A typical meteorological year (TMY) represents the typical meteorological conditions over many years but still contains the short term fluctuations which are absent from long-term averaged data. Meteorological data were measured at the Experimental Station of Cajamar 'Las Palmerillas' (Cajamar Foundation) in Almeria, Spain, over 19 years at the meteorological station and in a reference greenhouse which is typical of those used in the region. The two sets of measurements were subjected to quality control analysis and then used to create TMY datasets using three different methodologies proposed in the literature. Three TMY datasets were generated for the external conditions and two for the greenhouse. They were assessed by using each as input to seven horticultural models and comparing the model results with those obtained by experiment in practical trials. In addition, the models were used with the meteorological data recorded during the trials. A scoring system was used to identify the best performing TMY in each application and then rank them in overall performance. The best methodology was that of Argiriou for both greenhouse and external conditions. The average relative errors between the seasonal values estimated using the 19-year dataset and those using the Argiriou greenhouse TMY were 2.2 % (reference evapotranspiration), -0.45 % (pepper crop transpiration), 3.4 % (pepper crop nitrogen uptake) and 0.8 % (green bean yield). The values obtained using the Argiriou external TMY were 1.8 % (greenhouse reference evapotranspiration), 0.6 % (external reference evapotranspiration), 4.7 % (greenhouse heat requirement) and 0.9 % (loquat harvest date). Using the models with the 19 individual years in the historical dataset showed that the year to year weather variability gave results which differed from the average values by ± 15 %. By comparison with results from other greenhouses it was shown that the greenhouse TMY is applicable to greenhouses which have a solar radiation transmission of approximately 65 % and rely on manual control of ventilation which constitute the majority in the south-east of Spain and in most Mediterranean greenhouse areas.

  17. Generation and evaluation of typical meteorological year datasets for greenhouse and external conditions on the Mediterranean coast

    NASA Astrophysics Data System (ADS)

    Fernández, M. D.; López, J. C.; Baeza, E.; Céspedes, A.; Meca, D. E.; Bailey, B.

    2015-08-01

    A typical meteorological year (TMY) represents the typical meteorological conditions over many years but still contains the short term fluctuations which are absent from long-term averaged data. Meteorological data were measured at the Experimental Station of Cajamar `Las Palmerillas' (Cajamar Foundation) in Almeria, Spain, over 19 years at the meteorological station and in a reference greenhouse which is typical of those used in the region. The two sets of measurements were subjected to quality control analysis and then used to create TMY datasets using three different methodologies proposed in the literature. Three TMY datasets were generated for the external conditions and two for the greenhouse. They were assessed by using each as input to seven horticultural models and comparing the model results with those obtained by experiment in practical trials. In addition, the models were used with the meteorological data recorded during the trials. A scoring system was used to identify the best performing TMY in each application and then rank them in overall performance. The best methodology was that of Argiriou for both greenhouse and external conditions. The average relative errors between the seasonal values estimated using the 19-year dataset and those using the Argiriou greenhouse TMY were 2.2 % (reference evapotranspiration), -0.45 % (pepper crop transpiration), 3.4 % (pepper crop nitrogen uptake) and 0.8 % (green bean yield). The values obtained using the Argiriou external TMY were 1.8 % (greenhouse reference evapotranspiration), 0.6 % (external reference evapotranspiration), 4.7 % (greenhouse heat requirement) and 0.9 % (loquat harvest date). Using the models with the 19 individual years in the historical dataset showed that the year to year weather variability gave results which differed from the average values by ± 15 %. By comparison with results from other greenhouses it was shown that the greenhouse TMY is applicable to greenhouses which have a solar radiation transmission of approximately 65 % and rely on manual control of ventilation which constitute the majority in the south-east of Spain and in most Mediterranean greenhouse areas.

  18. NASA visual thesaurus maintenance documentation

    NASA Technical Reports Server (NTRS)

    1989-01-01

    The following document is presented in six sections: (1) introduction; (2) a diagram showing how the various routines are grouped together into functional modules; (3) a printout of all the layouts in the system along with their associated layout procedures; (4) listings of all the global procedures in the system; (5) a cross-reference of all identifiers used in the system; and (6) descriptions of the external procedures used in the system. The document was prepared at the Project ICON Image Scaling Laboratory.

  19. The Experimental Research on Seismic Capacity of the Envelope Systems with Steel Frame

    NASA Astrophysics Data System (ADS)

    Li, Jiuyang; Wang, Bingbing; Li, Hengxu

    2017-09-01

    In this paper, according to the present application situation of the external envelope systems steel frame in the severe cold region, the stuffed composite wall panels are improved, the flexible connection with the steel frame is designed, the reduced scale specimens are made, the seismic capacity test is made and some indexes of the envelope systems such as bearing capacity, energy consumption and ductility, etc. are compared, which provide reference for the development and application of the steel frame envelope systems.

  20. Development of an evidence-based approach to external quality assurance for breast cancer hormone receptor immunohistochemistry: comparison of reference values.

    PubMed

    Makretsov, Nikita; Gilks, C Blake; Alaghehbandan, Reza; Garratt, John; Quenneville, Louise; Mercer, Joel; Palavdzic, Dragana; Torlakovic, Emina E

    2011-07-01

    External quality assurance and proficiency testing programs for breast cancer predictive biomarkers are based largely on traditional ad hoc design; at present there is no universal consensus on definition of a standard reference value for samples used in external quality assurance programs. To explore reference values for estrogen receptor and progesterone receptor immunohistochemistry in order to develop an evidence-based analytic platform for external quality assurance. There were 31 participating laboratories, 4 of which were previously designated as "expert" laboratories. Each participant tested a tissue microarray slide with 44 breast carcinomas for estrogen receptor and progesterone receptor and submitted it to the Canadian Immunohistochemistry Quality Control Program for analysis. Nuclear staining in 1% or more of the tumor cells was a positive score. Five methods for determining reference values were compared. All reference values showed 100% agreement for estrogen receptor and progesterone receptor scores, when indeterminate results were excluded. Individual laboratory performance (agreement rates, test sensitivity, test specificity, positive predictive value, negative predictive value, and κ value) was very similar for all reference values. Identification of suboptimal performance by all methods was identical for 30 of 31 laboratories. Estrogen receptor assessment of 1 laboratory was discordant: agreement was less than 90% for 3 of 5 reference values and greater than 90% with the use of 2 other reference values. Various reference values provide equivalent laboratory rating. In addition to descriptive feedback, our approach allows calculation of technical test sensitivity and specificity, positive and negative predictive values, agreement rates, and κ values to guide corrective actions.

  1. Biologically inspired information theory: Adaptation through construction of external reality models by living systems.

    PubMed

    Nakajima, Toshiyuki

    2015-12-01

    Higher animals act in the world using their external reality models to cope with the uncertain environment. Organisms that have not developed such information-processing organs may also have external reality models built in the form of their biochemical, physiological, and behavioral structures, acquired by natural selection through successful models constructed internally. Organisms subject to illusions would fail to survive in the material universe. How can organisms, or living systems in general, determine the external reality from within? This paper starts with a phenomenological model, in which the self constitutes a reality model developed through the mental processing of phenomena. Then, the it-from-bit concept is formalized using a simple mathematical model. For this formalization, my previous work on an algorithmic process is employed to constitute symbols referring to the external reality, called the inverse causality, with additional improvements to the previous work. Finally, as an extension of this model, the cognizers system model is employed to describe the self as one of many material entities in a world, each of which acts as a subject by responding to the surrounding entities. This model is used to propose a conceptual framework of information theory that can deal with both the qualitative (semantic) and quantitative aspects of the information involved in biological processes. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Evidence from Visuomotor Adaptation for Two Partially Independent Visuomotor Systems

    ERIC Educational Resources Information Center

    Thaler, Lore; Todd, James T.

    2010-01-01

    Visual information can specify spatial layout with respect to the observer (egocentric) or with respect to an external frame of reference (allocentric). People can use both of these types of visual spatial information to guide their hands. The question arises if movements based on egocentric and movements based on allocentric visual information…

  3. Chaotic oscillation and random-number generation based on nanoscale optical-energy transfer.

    PubMed

    Naruse, Makoto; Kim, Song-Ju; Aono, Masashi; Hori, Hirokazu; Ohtsu, Motoichi

    2014-08-12

    By using nanoscale energy-transfer dynamics and density matrix formalism, we demonstrate theoretically and numerically that chaotic oscillation and random-number generation occur in a nanoscale system. The physical system consists of a pair of quantum dots (QDs), with one QD smaller than the other, between which energy transfers via optical near-field interactions. When the system is pumped by continuous-wave radiation and incorporates a timing delay between two energy transfers within the system, it emits optical pulses. We refer to such QD pairs as nano-optical pulsers (NOPs). Irradiating an NOP with external periodic optical pulses causes the oscillating frequency of the NOP to synchronize with the external stimulus. We find that chaotic oscillation occurs in the NOP population when they are connected by an external time delay. Moreover, by evaluating the time-domain signals by statistical-test suites, we confirm that the signals are sufficiently random to qualify the system as a random-number generator (RNG). This study reveals that even relatively simple nanodevices that interact locally with each other through optical energy transfer at scales far below the wavelength of irradiating light can exhibit complex oscillatory dynamics. These findings are significant for applications such as ultrasmall RNGs.

  4. Detection of multiple chemicals based on external cavity quantum cascade laser spectroscopy

    NASA Astrophysics Data System (ADS)

    Sun, Juan; Ding, Junya; Liu, Ningwu; Yang, Guangxiang; Li, Jingsong

    2018-02-01

    A laser spectroscopy system based on a broadband tunable external cavity quantum cascade laser (ECQCL) and a mini quartz crystal tuning fork (QCTF) detector was developed for standoff detection of volatile organic compounds (VOCs). The self-established spectral analysis model based on multiple algorithms for quantitative and qualitative analysis of VOC components (i.e. ethanol and acetone) was detailedly investigated in both closed cell and open path configurations. A good agreement was obtained between the experimentally observed spectra and the standard reference spectra. For open path detection of VOCs, the sensor system was demonstrated at a distance of 30 m. The preliminary laboratory results show that standoff detection of VOCs at a distance of over 100 m is very promising.

  5. Energy and environmental evaluation of combined cooling heating and power system

    NASA Astrophysics Data System (ADS)

    Bugaj, Andrzej

    2017-11-01

    The paper addresses issues involving problems of implementing combined cooling, heating and power (CCHP) system to industrial facility with well-defined demand profiles of cooling, heating and electricity. The application of CCHP system in this particular industrial facility is being evaluated by comparison with the reference system that consists of three conventional methods of energy supply: (a) electricity from external grid, (b) heat from gas-fired boilers and (c) cooling from vapour compression chillers run by electricity from the grid. The CCHP system scenario is based on the combined heat and power (CHP) plant with gas turbine-compressor arrangement and water/lithium bromide absorption chiller of a single-effect type. Those two scenarios are analysed in terms of annual primary energy usage as well as emissions of CO2. The results of the analysis show an extent of primary energy savings of the CCHP system in comparison with the reference system. Furthermore, the environmental impact of the CCHP usage, in the form of greenhouse gases emission reductions, compares quite favourably with the reference conventional option.

  6. TLD and OSLD dosimetry systems for remote audits of radiotherapy external beam calibration.

    PubMed

    Alvarez, P; Kry, S F; Stingo, F; Followill, D

    2017-11-01

    The Imaging and Radiation Oncology Core QA Center in Houston (IROC-H) performs remote dosimetry audits of more than 20,000 megavoltage photon and electron beams each year. Both a thermoluminescent dosimeter (TLD-100) and optically stimulated luminescent dosimeter (OSLD; nanoDot) system are commissioned for this task, with the OSLD system being predominant due to the more time-efficient read-out process. The measurement apparatus includes 3 TLD or 2 OSLD in an acrylic mini-phantom, which are irradiated by the institution under reference geometry. Dosimetry systems are calibrated based on the signal-to-dose conversion established with reference dosimeters irradiated in a Co-60 beam, using a reference dose of 300 cGy for TLD and 100 cGy for OSLD. The uncertainty in the dose determination is 1.3% for TLD and 1.6% for OSLD at the one sigma level. This accuracy allows for a tolerance of ±5% to be used.

  7. Validation of psychoanalytic theories: towards a conceptualization of references.

    PubMed

    Zachrisson, Anders; Zachrisson, Henrik Daae

    2005-10-01

    The authors discuss criteria for the validation of psychoanalytic theories and develop a heuristic and normative model of the references needed for this. Their core question in this paper is: can psychoanalytic theories be validated exclusively from within psychoanalytic theory (internal validation), or are references to sources of knowledge other than psychoanalysis also necessary (external validation)? They discuss aspects of the classic truth criteria correspondence and coherence, both from the point of view of contemporary psychoanalysis and of contemporary philosophy of science. The authors present arguments for both external and internal validation. Internal validation has to deal with the problems of subjectivity of observations and circularity of reasoning, external validation with the problem of relevance. They recommend a critical attitude towards psychoanalytic theories, which, by carefully scrutinizing weak points and invalidating observations in the theories, reduces the risk of wishful thinking. The authors conclude by sketching a heuristic model of validation. This model combines correspondence and coherence with internal and external validation into a four-leaf model for references for the process of validating psychoanalytic theories.

  8. Long life reference electrode

    DOEpatents

    Yonco, R.M.; Nagy, Z.

    1987-07-30

    An external, reference electrode is provided for long term use with a high temperature, high pressure system. The electrode is arranged in a vertical, electrically insulative tube with an upper portion serving as an electrolyte reservoir and a lower portion in electrolytic communication with the system to be monitored. The lower end portion includes a flow restriction such as a porous plug to limit the electrolyte release into the system. A piston equalized to the system pressure is fitted into the upper portion of the tube to impart a small incremental pressure to the electrolyte. The piston is selected of suitable size and weight to cause only a slight flow of electrolyte through the porous plug into the high pressure system. This prevents contamination of the electrolyte but is of such small flow rate that operating intervals of a month or more can be achieved. 2 figs.

  9. Long life reference electrode

    DOEpatents

    Yonco, R.M.; Nagy, Z.

    1989-04-04

    An external, reference electrode is provided for long term use with a high temperature, high pressure system. The electrode is arranged in a vertical, electrically insulative tube with an upper portion serving as an electrolyte reservoir and a lower portion in electrolytic communication with the system to be monitored. The lower end portion includes a flow restriction such as a porous plug to limit the electrolyte release into the system. A piston equalized to the system pressure is fitted into the upper portion of the tube to impart a small incremental pressure to the electrolyte. The piston is selected of suitable size and weight to cause only a slight flow of electrolyte through the porous plug into the high pressure system. This prevents contamination of the electrolyte but is of such small flow rate that operating intervals of a month or more can be achieved. 2 figs.

  10. Long life reference electrode

    DOEpatents

    Yonco, Robert M.; Nagy, Zoltan

    1989-01-01

    An external, reference electrode is provided for long term use with a high temperature, high pressure system. The electrode is arranged in a vertical, electrically insulative tube with an upper portion serving as an electrolyte reservior and a lower portion in electrolytic communication with the system to be monitored. The lower end portion includes a flow restriction such as a porous plug to limit the electrolyte release into the system. A piston equalized to the system pressure is fitted into the upper portion of the tube to impart a small incremental pressure to the electrolyte. The piston is selected of suitable size and weight to cause only a slight flow of electrolyte through the porous plug into the high pressure system. This prevents contamination of the electrolyte but is of such small flow rate that operating intervals of a month or more can be achieved.

  11. Autonomous identification of matrices in the APNea system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hensley, D.

    1995-12-31

    The APNea System is a passive and active neutron assay device which features imaging to correct for nonuniform distributions of source material. Since the imaging procedure requires a detailed knowledge of both the detection efficiency and the thermal neutron flux for (sub)volumes of the drum of interest, it is necessary to identify which mocked-up matrix, to be used for detailed characterization studies, best matches the matrix of interest. A methodology referred to as the external matrix probe (EMP) has been established which links external measures of a drum matrix to those of mocked-up matrices. These measures by themselves are sufficientmore » to identify the appropriate mock matrix, from which the necessary characterization data are obtained. This independent matrix identification leads to an autonomous determination of the required system response parameters for the assay analysis.« less

  12. Autonomous identification of matrices in the APNea System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hensley, D.

    1995-12-31

    The APNea System is a passive and active neutron assay device which features imaging to correct for nonuniform distributions of source material. Since the imaging procedure requires a detailed knowledge of both the detection efficiency and the thermal neutron flux for (sub)volumes of the drum of interest, it is necessary to identify which mocked-up matrix, to be used for detailed characterization studies, best matches the matrix of interest. A methodology referred to as the external matrix probe (EMP) has been established which links external measures of a drum matrix to those of mocked-up matrices. These measures by themselves are sufficientmore » to identify the appropriate mock matrix, from which the necessary characterization data are obtained. This independent matrix identification leads to an autonomous determination of the required system response parameters for the assay analysis.« less

  13. A direct-view customer-oriented digital holographic camera

    NASA Astrophysics Data System (ADS)

    Besaga, Vira R.; Gerhardt, Nils C.; Maksimyak, Peter P.; Hofmann, Martin R.

    2018-01-01

    In this paper, we propose a direct-view digital holographic camera system consisting mostly of customer-oriented components. The camera system is based on standard photographic units such as camera sensor and objective and is adapted to operate under off-axis external white-light illumination. The common-path geometry of the holographic module of the system ensures direct-view operation. The system can operate in both self-reference and self-interference modes. As a proof of system operability, we present reconstructed amplitude and phase information of a test sample.

  14. The NCI Thesaurus quality assurance life cycle.

    PubMed

    de Coronado, Sherri; Wright, Lawrence W; Fragoso, Gilberto; Haber, Margaret W; Hahn-Dantona, Elizabeth A; Hartel, Francis W; Quan, Sharon L; Safran, Tracy; Thomas, Nicole; Whiteman, Lori

    2009-06-01

    The National Cancer Institute Enterprise Vocabulary Services (NCI EVS) uses a wide range of quality assurance (QA) techniques to maintain and extend NCI Thesaurus (NCIt). NCIt is a reference terminology and biomedical ontology used in a growing number of NCI and other systems that extend from translational and basic research through clinical care to public information and administrative activities. Both automated and manual QA techniques are employed throughout the editing and publication cycle, which includes inserting and editing NCIt in NCI Metathesaurus. NCI EVS conducts its own additional periodic and ongoing content QA. External reviews, and extensive evaluation by and interaction with EVS partners and other users, have also played an important part in the QA process. There have always been tensions and compromises between meeting the needs of dependent systems and providing consistent and well-structured content; external QA and feedback have been important in identifying and addressing such issues. Currently, NCI EVS is exploring new approaches to broaden external participation in the terminology development and QA process.

  15. Effect of inertia properties on attitude stability of nonrigid spin-stabilized spacecraft

    NASA Technical Reports Server (NTRS)

    Lang, W. E.; Young, J. P.

    1974-01-01

    The phenomenon of energy dissipation in spinning spacecraft is discussed with particular reference to its dependence on spacecraft inertia properties. Specific dissipation mechanisms are identified. The effect of external environmental factors on spin stability is also discussed. Generalized curves are presented relating system stability to the principal inertia ratio for various forms of energy dissipation. Dual-spin systems and the effect of lateral inertia asymmetry are also reviewed.

  16. Reduction of photographic observations of asteroids to the reference frame of a single catalog

    NASA Astrophysics Data System (ADS)

    Chernetenko, Yu. A.

    2008-04-01

    In 2000, the last international program of photographic observations of selected asteroids aimed at the determination of the mutual orientation of the dynamic and stellar coordinate systems came to an end. The Institute of Applied Astronomy of the Russian Academy of Sciences collected more than 25 000 observations for 15 asteroids spanning from 1949 through 1995. These observations were reduced to the reference frame of the Hipparcos catalog using dependencies published along with observations. The accuracy of observations of selected asteroids was 0.30 arcsec, which is comparable to that of modern CCD observations of minor planets. The observations are available at ftp://quasar.ipa.nw.ru/pub/SMP . An important advantage of these observations is that they are already reduced to the reference frame of a single catalog. Our criteria for the quality of the reduction methods and the accuracy of the observations are based on estimating the parameters of the orientation of the reference frames of the PPM and Hipparcos catalogs with respect to DE200/LE200. The most reliable results are those obtained when reducing old optical observations along with modern ground-based and space-borne observations.

  17. Implementation of a National Reference Laboratory for Buruli Ulcer Disease in Togo

    PubMed Central

    Badziklou, Kossi; Halatoko, Wemboo Afiwa; Maman, Issaka; Vogel, Felix; Bidjada, Bawimodom; Awoussi, Koffi Somenou; Piten, Ebekalisai; Helfrich, Kerstin; Mengele, Carolin; Nitschke, Jörg; Amekuse, Komi; Wiedemann, Franz Xaver; Diefenhardt, Adolf; Kobara, Basile; Herbinger, Karl–Heinz; Kere, Abiba Banla; Prince-David, Mireille; Löscher, Thomas; Bretzel, Gisela

    2013-01-01

    Background In a previous study PCR analysis of clinical samples from suspected cases of Buruli ulcer disease (BUD) from Togo and external quality assurance (EQA) for local microscopy were conducted at an external reference laboratory in Germany. The relatively poor performance of local microscopy as well as effort and time associated with shipment of PCR samples necessitated the implementation of stringent EQA measures and availability of local laboratory capacity. This study describes the approach to implementation of a national BUD reference laboratory in Togo. Methodology Large scale outreach activities accompanied by regular training programs for health care professionals were conducted in the regions “Maritime” and “Central,” standard operating procedures defined all processes in participating laboratories (regional, national and external reference laboratories) as well as the interaction between laboratories and partners in the field. Microscopy was conducted at regional level and slides were subjected to EQA at national and external reference laboratories. For PCR analysis, sample pairs were collected and subjected to a dry-reagent-based IS2404-PCR (DRB-PCR) at national level and standard IS2404 PCR followed by IS2404 qPCR analysis of negative samples at the external reference laboratory. Principal Findings The inter-laboratory concordance rates for microscopy ranged from 89% to 94%; overall, microscopy confirmed 50% of all suspected BUD cases. The inter-laboratory concordance rate for PCR was 96% with an overall PCR case confirmation rate of 78%. Compared to a previous study, the rate of BUD patients with non-ulcerative lesions increased from 37% to 50%, the mean duration of disease before clinical diagnosis decreased significantly from 182.6 to 82.1 days among patients with ulcerative lesions, and the percentage of category III lesions decreased from 30.3% to 19.2%. Conclusions High inter-laboratory concordance rates as well as case confirmation rates of 50% (microscopy), 71% (PCR at national level), and 78% (including qPCR confirmation at external reference laboratory) suggest high standards of BUD diagnostics. The increase of non-ulcerative lesions, as well as the decrease in diagnostic delay and category III lesions, prove the effect of comprehensive EQA and training measures involving also procedures outside the laboratory. PMID:23359828

  18. Implementation of a national reference laboratory for Buruli ulcer disease in Togo.

    PubMed

    Beissner, Marcus; Huber, Kristina Lydia; Badziklou, Kossi; Halatoko, Wemboo Afiwa; Maman, Issaka; Vogel, Felix; Bidjada, Bawimodom; Awoussi, Koffi Somenou; Piten, Ebekalisai; Helfrich, Kerstin; Mengele, Carolin; Nitschke, Jörg; Amekuse, Komi; Wiedemann, Franz Xaver; Diefenhardt, Adolf; Kobara, Basile; Herbinger, Karl-Heinz; Kere, Abiba Banla; Prince-David, Mireille; Löscher, Thomas; Bretzel, Gisela

    2013-01-01

    In a previous study PCR analysis of clinical samples from suspected cases of Buruli ulcer disease (BUD) from Togo and external quality assurance (EQA) for local microscopy were conducted at an external reference laboratory in Germany. The relatively poor performance of local microscopy as well as effort and time associated with shipment of PCR samples necessitated the implementation of stringent EQA measures and availability of local laboratory capacity. This study describes the approach to implementation of a national BUD reference laboratory in Togo. Large scale outreach activities accompanied by regular training programs for health care professionals were conducted in the regions "Maritime" and "Central," standard operating procedures defined all processes in participating laboratories (regional, national and external reference laboratories) as well as the interaction between laboratories and partners in the field. Microscopy was conducted at regional level and slides were subjected to EQA at national and external reference laboratories. For PCR analysis, sample pairs were collected and subjected to a dry-reagent-based IS2404-PCR (DRB-PCR) at national level and standard IS2404 PCR followed by IS2404 qPCR analysis of negative samples at the external reference laboratory. The inter-laboratory concordance rates for microscopy ranged from 89% to 94%; overall, microscopy confirmed 50% of all suspected BUD cases. The inter-laboratory concordance rate for PCR was 96% with an overall PCR case confirmation rate of 78%. Compared to a previous study, the rate of BUD patients with non-ulcerative lesions increased from 37% to 50%, the mean duration of disease before clinical diagnosis decreased significantly from 182.6 to 82.1 days among patients with ulcerative lesions, and the percentage of category III lesions decreased from 30.3% to 19.2%. High inter-laboratory concordance rates as well as case confirmation rates of 50% (microscopy), 71% (PCR at national level), and 78% (including qPCR confirmation at external reference laboratory) suggest high standards of BUD diagnostics. The increase of non-ulcerative lesions, as well as the decrease in diagnostic delay and category III lesions, prove the effect of comprehensive EQA and training measures involving also procedures outside the laboratory.

  19. Change of reference frame for tactile localization during child development.

    PubMed

    Pagel, Birthe; Heed, Tobias; Röder, Brigitte

    2009-11-01

    Temporal order judgements (TOJ) for two tactile stimuli, one presented to the left and one to the right hand, are less precise when the hands are crossed over the midline than when the hands are uncrossed. This 'crossed hand' effect has been considered as evidence for a remapping of tactile input into an external reference frame. Since late, but not early, blind individuals show such remapping, it has been hypothesized that the use of an external reference frame develops during childhood. Five- to 10-year-old children were therefore tested with the tactile TOJ task, both with uncrossed and crossed hands. Overall performance in the TOJ task improved with age. While children older than 5 1/2 years displayed a crossed hand effect, younger children did not. Therefore the use of an external reference frame for tactile, and possibly multisensory, localization seems to be acquired at age 5.

  20. Accuracy and feasibility of three different methods for software-based image fusion in whole-body PET and CT.

    PubMed

    Putzer, Daniel; Henninger, Benjamin; Kovacs, Peter; Uprimny, Christian; Kendler, Dorota; Jaschke, Werner; Bale, Reto J

    2016-06-01

    Even as PET/CT provides valuable diagnostic information in a great number of clinical indications, availability of hybrid PET/CT scanners is mainly limited to clinical centers. A software-based image fusion would facilitate combined image reading of CT and PET data sets if hardware image fusion is not available. To analyze the relevance of retrospective image fusion of separately acquired PET and CT data sets, we studied the accuracy, practicability and reproducibility of three different image registration techniques. We evaluated whole-body 18F-FDG-PET and CT data sets of 71 oncologic patients. Images were fused retrospectively using Stealth Station System, Treon (Medtronic Inc., Louisville, CO, USA) equipped with Cranial4 Software. External markers fixed to a vacuum mattress were used as reference for exact repositioning. Registration was repeated using internal anatomic landmarks and Automerge software, assessing accuracy for all three methods, measuring distances of liver representation in CT and PET with reference to a common coordinate system. On first measurement of image fusions with external markers, 53 were successful, 16 feasible and 2 not successful. Using anatomic landmarks, 42 were successful, 26 feasible and 3 not successful. Using Automerge Software only 13 were successful. The mean distance between center points in PET and CT was 7.69±4.96 mm on first, and 7.65±4.2 mm on second measurement. Results with external markers correlate very well and inaccuracies are significantly lower (P<0.001) than results using anatomical landmarks (10.38±6.13 mm and 10.83±6.23 mm). Analysis revealed a significantly faster alignment using external markers (P<0.001). External fiducials in combination with immobilization devices and breathing protocols allow for highly accurate image fusion cost-effectively and significantly less time, posing an attractive alternative for PET/CT interpretation when a hybrid scanner is not available.

  1. The Generalized Internal/External Frame of Reference Model: An Extension to Dimensional Comparison Theory

    ERIC Educational Resources Information Center

    Möller, Jens; Müller-Kalthoff, Hanno; Helm, Friederike; Nagy, Nicole; Marsh, Herb W.

    2016-01-01

    The dimensional comparison theory (DCT) focuses on the effects of internal, dimensional comparisons (e.g., "How good am I in math compared to English?") on academic self-concepts with widespread consequences for students' self-evaluation, motivation, and behavioral choices. DCT is based on the internal/external frame of reference model…

  2. Cognitive Ability, Academic Achievement and Academic Self-Concept: Extending the Internal/External Frame of Reference Model

    ERIC Educational Resources Information Center

    Chen, Ssu-Kuang; Hwang, Fang-Ming; Yeh, Yu-Chen; Lin, Sunny S. J.

    2012-01-01

    Background: Marsh's internal/external (I/E) frame of reference model depicts the relationship between achievement and self-concept in specific academic domains. Few efforts have been made to examine concurrent relationships among cognitive ability, achievement, and academic self-concept (ASC) within an I/E model framework. Aim: To simultaneously…

  3. Improving the efficiency of quantitative (1)H NMR: an innovative external standard-internal reference approach.

    PubMed

    Huang, Yande; Su, Bao-Ning; Ye, Qingmei; Palaniswamy, Venkatapuram A; Bolgar, Mark S; Raglione, Thomas V

    2014-01-01

    The classical internal standard quantitative NMR (qNMR) method determines the purity of an analyte by the determination of a solution containing the analyte and a standard. Therefore, the standard must meet the requirements of chemical compatibility and lack of resonance interference with the analyte as well as a known purity. The identification of such a standard can be time consuming and must be repeated for each analyte. In contrast, the external standard qNMR method utilizes a standard with a known purity to calibrate the NMR instrument. The external standard and the analyte are measured separately, thereby eliminating the matter of chemical compatibility and resonance interference between the standard and the analyte. However, the instrumental factors, including the quality of NMR tubes, must be kept the same. Any deviations will compromise the accuracy of the results. An innovative qNMR method reported herein utilizes an internal reference substance along with an external standard to assume the role of the standard used in the traditional internal standard qNMR method. In this new method, the internal reference substance must only be chemically compatible and be free of resonance-interference with the analyte or external standard whereas the external standard must only be of a known purity. The exact purity or concentration of the internal reference substance is not required as long as the same quantity is added to the external standard and the analyte. The new method reduces the burden of searching for an appropriate standard for each analyte significantly. Therefore the efficiency of the qNMR purity assay increases while the precision of the internal standard method is retained. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. On the usefulness of relativistic space-times for the description of the Earth's gravitational field

    NASA Astrophysics Data System (ADS)

    Soffel, Michael; Frutos, Francisco

    2016-12-01

    The usefulness of relativistic space-times for the description of the Earth's gravitational field is investigated. A variety of exact vacuum solutions of Einstein's field equations (Schwarzschild, Erez and Rosen, Gutsunayev and Manko, Hernández-Pastora and Martín, Kerr, Quevedo, and Mashhoon) are investigated in that respect. It is argued that because of their multipole structure and influences from external bodies, all these exact solutions are not really useful for the central problem. Then, approximate space-times resulting from an MPM or post-Newtonian approximation are considered. Only in the DSX formalism that is of the first post-Newtonian order, all aspects of the problem can be tackled: a relativistic description (a) of the Earth's gravity field in a well-defined geocentric reference system (GCRS), (b) of the motion of solar system bodies in a barycentric reference system (BCRS), and (c) of inertial and tidal terms in the geocentric metric describing the external gravitational field. A relativistic SLR theory is also discussed with respect to our central problem. Orders of magnitude of many effects related to the Earth's gravitational field and SLR are given. It is argued that a formalism with accuracies better than of the first post-Newtonian order is not yet available.

  5. How to justify avoidance of communications related to death anxiety in the health care system.

    PubMed

    Sariyar, Murat

    2015-08-01

    It might seem obvious that dealing with death anxiety in the health care system is desirable. Hence, there are either voices that demand more research on how this openness can be fostered or those who consider this topic unworthy of further investigations because of its triviality. The idea behind both deficient perspectives is that the health care system as a communication system can assume the position of a second-order observer who can account for his deficits. However, in terms of Luhmannian systems theory, external perturbations cannot force a functional system to reflect and change the structure of his communications in a certain way. The health care system as a communication system cannot do more than integrating the topic of death anxiety in terms of its functional perpetuation. For example, in hospitals, neither health care staff nor external counselors are able to address existential issues without being affected by functional and structural requirements of the hospital. We present an outline for the justification of the avoidance of death-anxiety related talk in the health care system by reference to systems theory and existential philosophy.

  6. DIRBE External Calibrator (DEC)

    NASA Technical Reports Server (NTRS)

    Wyatt, Clair L.; Thurgood, V. Alan; Allred, Glenn D.

    1987-01-01

    Under NASA Contract No. NAS5-28185, the Center for Space Engineering at Utah State University has produced a calibration instrument for the Diffuse Infrared Background Experiment (DIRBE). DIRBE is one of the instruments aboard the Cosmic Background Experiment Observatory (COBE). The calibration instrument is referred to as the DEC (Dirbe External Calibrator). DEC produces a steerable, infrared beam of controlled spectral content and intensity and with selectable point source or diffuse source characteristics, that can be directed into the DIRBE to map fields and determine response characteristics. This report discusses the design of the DEC instrument, its operation and characteristics, and provides an analysis of the systems capabilities and performance.

  7. When Students Doubt Their Teachers' Diagnostic Competence: Moderation in the Internal/External Frame of Reference Model

    ERIC Educational Resources Information Center

    Zimmermann, Friederike; Möller, Jens; Köller, Olaf

    2018-01-01

    The internal/external frame of reference model (I/E model) posits that individuals' achievement-related self-concepts are formed through social comparisons (e.g., self vs. peers) within academic domains and dimensional comparisons (e.g., math vs. verbal) between distinct domains. A large body of research has supported the theorized pattern of…

  8. Antecedents of Academic Emotions: Testing the Internal/External Frame of Reference Model for Academic Enjoyment

    ERIC Educational Resources Information Center

    Goetz, Thomas; Frenzel, Anne C.; Hall, Nathan C.; Pekrun, Reinhard

    2008-01-01

    The present study focused on students' academic enjoyment as predicted by achievement in multiple academic domains. Assumptions were based on Marsh's internal/external (I/E) frame of reference model and Pekrun's control-value theory of achievement emotions, and were tested in a sample of 1380 German students from grades 5 to 10. Students' academic…

  9. The Reciprocal Internal/External Frame of Reference Model Using Grades and Test Scores

    ERIC Educational Resources Information Center

    Möller, Jens; Zimmermann, Friederike; Köller, Olaf

    2014-01-01

    Background: The reciprocal I/E model (RI/EM) combines the internal/external frame of reference model (I/EM) with the reciprocal effects model (REM). The RI/EM extends the I/EM longitudinally and the REM across domains. The model predicts that, within domains, mathematics and verbal achievement (VACH) and academic self-concept have positive effects…

  10. The efficacy of systemic therapy for childhood and adolescent externalizing disorders: a systematic review of 47 RCT.

    PubMed

    von Sydow, Kirsten; Retzlaff, Ruediger; Beher, Stefan; Haun, Markus W; Schweitzer, Jochen

    2013-12-01

    Systemic (family) therapy is a widely used psychotherapy approach. However, most systematic efficacy reviews have focused solely on "family-based treatment" rather than on the theoretic orientation "systemic therapy." We systematically review trials on the efficacy of systemic therapy for the treatment of childhood and adolescent externalizing disorders. All randomized (or matched) controlled trials (RCT) evaluating systemic/systems-oriented therapy in various forms (family, individual, group, multi-family group therapy) with child or adolescent index patients (0-17 years) suffering from mental disorders were identified by data base searches and cross-references. Inclusion criteria were as follows: index patient diagnosed with a DSM- or ICD-listed mental disorder, and trial published in any language up to the end of 2011. The RCTs were analyzed for their research methodology, interventions applied, and results (postintervention; follow-up). A total of 47 trials from the United States, Europe, and China, published in English, German, and Mandarin, were identified. A total of 42 of them showed systemic therapy to be efficacious for the treatment of attention deficit hyperactivity disorders, conduct disorders, and substance use disorders. Results were stable across follow-up periods of up to 14 years. There is a sound evidence base for the efficacy of systemic therapy for children and adolescents (and their families) diagnosed with externalizing disorders. © FPI, Inc.

  11. Partial and total actuator faults accommodation for input-affine nonlinear process plants.

    PubMed

    Mihankhah, Amin; Salmasi, Farzad R; Salahshoor, Karim

    2013-05-01

    In this paper, a new fault-tolerant control system is proposed for input-affine nonlinear plants based on Model Reference Adaptive System (MRAS) structure. The proposed method has the capability to accommodate both partial and total actuator failures along with bounded external disturbances. In this methodology, the conventional MRAS control law is modified by augmenting two compensating terms. One of these terms is added to eliminate the nonlinear dynamic, while the other is reinforced to compensate the distractive effects of the total actuator faults and external disturbances. In addition, no Fault Detection and Diagnosis (FDD) unit is needed in the proposed method. Moreover, the control structure has good robustness capability against the parameter variation. The performance of this scheme is evaluated using a CSTR system and the results were satisfactory. Copyright © 2013 ISA. Published by Elsevier Ltd. All rights reserved.

  12. Noise-induced volatility of collective dynamics

    NASA Astrophysics Data System (ADS)

    Harras, Georges; Tessone, Claudio J.; Sornette, Didier

    2012-01-01

    Noise-induced volatility refers to a phenomenon of increased level of fluctuations in the collective dynamics of bistable units in the presence of a rapidly varying external signal, and intermediate noise levels. The archetypical signature of this phenomenon is that—beyond the increase in the level of fluctuations—the response of the system becomes uncorrelated with the external driving force, making it different from stochastic resonance. Numerical simulations and an analytical theory of a stochastic dynamical version of the Ising model on regular and random networks demonstrate the ubiquity and robustness of this phenomenon, which is argued to be a possible cause of excess volatility in financial markets, of enhanced effective temperatures in a variety of out-of-equilibrium systems, and of strong selective responses of immune systems of complex biological organisms. Extensive numerical simulations are compared with a mean-field theory for different network topologies.

  13. On the Addition of EM Field Propagation and Coupling Effects in the BLT Equation. Revision

    DTIC Science & Technology

    2004-06-08

    which collectively are referred to as high power electromagnetic ( HPEM ) fields, could be inadvertent, like the environment produced by a search...either case, the effects of these HPEM fields may include system upset, and in some cases, permanent damage. Figure 1 illustrates a simple example of...an electrical system excited by an external HPEM source. This energy source can provide either a narrow-band pulsed EM field, or a fast transient

  14. Inhibited attachment behaviour and disinhibited social engagement behaviour as relevant concepts in referred home reared children.

    PubMed

    Scheper, F Y; Abrahamse, M E; Jonkman, C S; Schuengel, C; Lindauer, R J L; de Vries, A L C; Doreleijers, T A H; Jansen, L M C

    2016-07-01

    Disorders of attachment and social engagement have mainly been studied in children, reared in institutions and foster care. There are few studies amongst home reared children living with biological parents. The aim of this study was to test the clinical significance of inhibited attachment behaviour and disinhibited social engagement behaviour in young home reared children, referred for treatment of emotional and behavioural problems, compared with young children in treatment foster care. The Disturbances of Attachment Interview, Maltreatment Classification System, the Child Behaviour Checklist and Parenting Stress Index were used in 141 referred home reared children and 59 referred foster children, aged 2.0-7.9 years (M = 4.7, SE = 1.3), 71% boys. Inhibited attachment behaviour was less prevalent in the referred home reared group (9%) than in the foster care group (27%). Disinhibited social engagement behaviour was found in 42% of the home reared group, similar to the foster care group. Inhibited attachment behaviour and disinhibited social engagement behaviour were not associated with child maltreatment. More inhibited attachment behaviour was associated with clinical levels of child internalizing and externalizing behaviour in the home reared group, not in the foster care group. In both groups, more disinhibited social engagement behaviour was associated with clinical levels of externalizing behaviour and with more parenting stress. Even without evident links to maltreatment, results of this study suggest clinical significance of inhibited attachment behaviour and disinhibited social engagement behaviour in young home reared children referred for treatment of emotional and behavioural problems. © 2016 John Wiley & Sons Ltd.

  15. Comparison of methods for the prediction of human clearance from hepatocyte intrinsic clearance for a set of reference compounds and an external evaluation set.

    PubMed

    Yamagata, Tetsuo; Zanelli, Ugo; Gallemann, Dieter; Perrin, Dominique; Dolgos, Hugues; Petersson, Carl

    2017-09-01

    1. We compared direct scaling, regression model equation and the so-called "Poulin et al." methods to scale clearance (CL) from in vitro intrinsic clearance (CL int ) measured in human hepatocytes using two sets of compounds. One reference set comprised of 20 compounds with known elimination pathways and one external evaluation set based on 17 compounds development in Merck (MS). 2. A 90% prospective confidence interval was calculated using the reference set. This interval was found relevant for the regression equation method. The three outliers identified were justified on the basis of their elimination mechanism. 3. The direct scaling method showed a systematic underestimation of clearance in both the reference and evaluation sets. The "Poulin et al." and the regression equation methods showed no obvious bias in either the reference or evaluation sets. 4. The regression model equation was slightly superior to the "Poulin et al." method in the reference set and showed a better absolute average fold error (AAFE) of value 1.3 compared to 1.6. A larger difference was observed in the evaluation set were the regression method and "Poulin et al." resulted in an AAFE of 1.7 and 2.6, respectively (removing the three compounds with known issues mentioned above). A similar pattern was observed for the correlation coefficient. Based on these data we suggest the regression equation method combined with a prospective confidence interval as the first choice for the extrapolation of human in vivo hepatic metabolic clearance from in vitro systems.

  16. Statistical foundations of liquid-crystal theory: I. Discrete systems of rod-like molecules.

    PubMed

    Seguin, Brian; Fried, Eliot

    2012-12-01

    We develop a mechanical theory for systems of rod-like particles. Central to our approach is the assumption that the external power expenditure for any subsystem of rods is independent of the underlying frame of reference. This assumption is used to derive the basic balance laws for forces and torques. By considering inertial forces on par with other forces, these laws hold relative to any frame of reference, inertial or noninertial. Finally, we introduce a simple set of constitutive relations to govern the interactions between rods and find restrictions necessary and sufficient for these laws to be consistent with thermodynamics. Our framework provides a foundation for a statistical mechanical derivation of the macroscopic balance laws governing liquid crystals.

  17. Frame of Reference Model of Self-Concept and Locus of Control: A Cross Gender Study in the United Arab Emirates.

    ERIC Educational Resources Information Center

    Abu-Hilal, Maher M.

    A study tested predictions for I/E (internal external) frame of reference model and extended this model to include locus of control. A sample of upper elementary (n=181) and junior high (n=191) students in the United Arab Emirates participated in the study. Structural equation modeling (SEM) analyses provided support to the external comparison…

  18. The Internal/External Frame of Reference Model of Self-Concept and Achievement Relations: Age-Cohort and Cross-Cultural Differences

    ERIC Educational Resources Information Center

    Marsh, Herbert W.; Abduljabbar, Adel Salah; Parker, Philip D.; Morin, Alexandre J. S.; Abdelfattah, Faisal; Nagengast, Benjamin; Möller, Jens; Abu-Hilal, Maher M.

    2015-01-01

    The internal/external frame of reference (I/E) model and dimensional comparison theory posit paradoxical relations between achievement (ACH) and self-concept (SC) in mathematics (M) and verbal (V) domains; ACH in each domain positively affects SC in the matching domain (e.g., MACH to MSC) but negatively in the nonmatching domain (e.g., MACH to…

  19. Verbal and Math Self-Concepts: An Extension of the Internal/External Frame of Reference Model.

    ERIC Educational Resources Information Center

    Marsh, Herbert W.; Byrne, Barbara M.

    The internal/external (I/E) frame of reference model describes relations among Verbal self-concept (VSC), Math self-concept (MSC), and corresponding achievement scores (VACH, MACH). In support of the model Marsh (1986) found that: (1) VSC and MSC were nearly uncorrelated; (2) the effect of VACH on VSC, and of MACH on MSC, were positive; but (3)…

  20. The effects of internal and external control factors on college students' marijuana use and cessation of use.

    PubMed

    Lo, C C; Globetti, G

    1995-01-01

    The purpose of this study was to examine how selected internal and external control variables influence lifetime use, frequency of use, and cessation of use of marijuana. The internal control factor, comprising the variables 1) perceived risk of marijuana use and 2) attitudes toward prohibition of marijuana use, refers to a built-in personal tendency toward conventionality. The external control factor refers to social-environmental forces which discourage marijuana use. External control is indicated by factors including the number of extra-curricular activities in which an individual is involved; place of residence; the availability of marijuana; peer attitudes toward marijuana use; the number of an individual's friends who use marijuana; and the number of occasions on which an individual has observed others using marijuana. The study's results show that both internal and external control factors are significant predictors of the frequency of marijuana use. The external control factor, however, plays a more important role in explaining lifetime marijuana use and cessation of marijuana use.

  1. Reference earth orbital research and applications investigations (blue book). Volume 7: Technology

    NASA Technical Reports Server (NTRS)

    1971-01-01

    The candidate experiment program for manned space stations with specific application to technology disciplines is presented. The five functional program elements are devoted to the development of new technology for application to future generation spacecraft and experiments. The functional program elements are as follows: (1) monitor and trace movement of external contaminants to determine methods for controlling contamination, (2) analysis of fundamentals of fluid systems management, (3) extravehicular activity, (4) advanced spacecraft systems tests, and (5) development of teleoperator system for use with space activities.

  2. Comparing pharmaceutical pricing and reimbursement policies in Croatia to the European Union Member States.

    PubMed

    Vogler, Sabine; Habl, Claudia; Bogut, Martina; Voncina, Luka

    2011-04-15

    To perform a comparative analysis of the pharmaceutical pricing and reimbursement systems in Croatia and the 27 European Union (EU) Member States. Knowledge about the pharmaceutical systems in Croatia and the 27 EU Member States was acquired by literature review and primary research with stakeholders. Pharmaceutical prices are controlled at all levels in Croatia, which is also the case in 21 EU Member States. Like many EU countries, Croatia also applies external price referencing, i.e., compares prices with other countries. While the wholesale remuneration by a statutorily regulated linear mark-up is applied in Croatia and in several EU countries, the pharmacy compensation for dispensing reimbursable medicines in the form of a flat rate service fee in Croatia is rare among EU countries, which usually apply a linear or regressive pharmacy mark-up scheme. Like in most EU countries, the Croatian Social Insurance reimburses specific medicines at 100%, whereas patients are charged co-payments for other reimbursable medicines. Criteria for reimbursement include the medicine's importance from the public health perspective, its therapeutic value, and relative effectiveness. In Croatia and in many EU Member States, reimbursement is based on a reference price system. The Croatian pharmaceutical system is similar to those in the EU Member States. Key policies, like external price referencing and reference price systems, which have increasingly been introduced in EU countries are also applied in Croatia and serve the same purpose: to ensure access to medicines while containing public pharmaceutical expenditure.

  3. Load identification approach based on basis pursuit denoising algorithm

    NASA Astrophysics Data System (ADS)

    Ginsberg, D.; Ruby, M.; Fritzen, C. P.

    2015-07-01

    The information of the external loads is of great interest in many fields of structural analysis, such as structural health monitoring (SHM) systems or assessment of damage after extreme events. However, in most cases it is not possible to measure the external forces directly, so they need to be reconstructed. Load reconstruction refers to the problem of estimating an input to a dynamic system when the system output and the impulse response functions are usually the knowns. Generally, this leads to a so called ill-posed inverse problem, which involves solving an underdetermined linear system of equations. For most practical applications it can be assumed that the applied loads are not arbitrarily distributed in time and space, at least some specific characteristics about the external excitation are known a priori. In this contribution this knowledge was used to develop a more suitable force reconstruction method, which allows identifying the time history and the force location simultaneously by employing significantly fewer sensors compared to other reconstruction approaches. The properties of the external force are used to transform the ill-posed problem into a sparse recovery task. The sparse solution is acquired by solving a minimization problem known as basis pursuit denoising (BPDN). The possibility of reconstructing loads based on noisy structural measurement signals will be demonstrated by considering two frequently occurring loading conditions: harmonic excitation and impact events, separately and combined. First a simulation study of a simple plate structure is carried out and thereafter an experimental investigation of a real beam is performed.

  4. Monitoring with Data Automata

    NASA Technical Reports Server (NTRS)

    Havelund, Klaus

    2014-01-01

    We present a form of automaton, referred to as data automata, suited for monitoring sequences of data-carrying events, for example emitted by an executing software system. This form of automata allows states to be parameterized with data, forming named records, which are stored in an efficiently indexed data structure, a form of database. This very explicit approach differs from other automaton-based monitoring approaches. Data automata are also characterized by allowing transition conditions to refer to other parameterized states, and by allowing transitions sequences. The presented automaton concept is inspired by rule-based systems, especially the Rete algorithm, which is one of the well-established algorithms for executing rule-based systems. We present an optimized external DSL for data automata, as well as a comparable unoptimized internal DSL (API) in the Scala programming language, in order to compare the two solutions. An evaluation compares these two solutions to several other monitoring systems.

  5. Lunar base thermal management/power system analysis and design

    NASA Technical Reports Server (NTRS)

    Mcghee, Jerry R.

    1992-01-01

    A compilation of several lunar surface thermal management and power system studies completed under contract and IR&D is presented. The work includes analysis and preliminary design of all major components of an integrated thermal management system, including loads determination, active internal acquisition and transport equipment, external transport systems (active and passive), passive insulation, solar shielding, and a range of lunar surface radiator concepts. Several computer codes were utilized in support of this study, including RADSIM to calculate radiation exchange factors and view factors, RADIATOR (developed in-house) for heat rejection system sizing and performance analysis over a lunar day, SURPWER for power system sizing, and CRYSTORE for cryogenic system performance predictions. Although much of the work was performed in support of lunar rover studies, any or all of the results can be applied to a range of surface applications. Output data include thermal loads summaries, subsystem performance data, mass, and volume estimates (where applicable), integrated and worst-case lunar day radiator size/mass and effective sink temperatures for several concepts (shielded and unshielded), and external transport system performance estimates for both single and two-phase (heat pumped) transport loops. Several advanced radiator concepts are presented, along with brief assessments of possible system benefits and potential drawbacks. System point designs are presented for several cases, executed in support of the contract and IR&D studies, although the parametric nature of the analysis is stressed to illustrate applicability of the analysis procedure to a wide variety of lunar surface systems. The reference configuration(s) derived from the various studies will be presented along with supporting criteria. A preliminary design will also be presented for the reference basing scenario, including qualitative data regarding TPS concerns and issues.

  6. Hall effect in the presence of rotation

    NASA Astrophysics Data System (ADS)

    Zubkov, M. A.

    2018-02-01

    A rotating relativistic fermion system is considered. The consideration is based on the Dirac equation written in the laboratory (non-rotating) reference frame. Rotation in this approach gives rise to the effective magnetic and electric fields that act in the same way both on positive and negative electric charges. In the presence of external electric field in the given system the electric current appears orthogonal to both the electric field and the axis of rotation. The possible applications to the physics of quark-gluon plasma are discussed.

  7. Publications of the JPL Solar Thermal Power Systems Project, 1976 to 1983

    NASA Technical Reports Server (NTRS)

    Gray, V. (Compiler); Marsh, C. (Compiler); Panda, P. (Compiler)

    1984-01-01

    The bibliographical listings in this publication are documentation products associated with the solar thermal power system project carried out by the Jet Propulsion Laboratory from 1976 to 1983. Documents listed are categorized as conference and journal papers, JPL external reports, JPL internal reports, or contractor reports. Alphabetical listings by title were used in the bibliography itself to facilitate location of the document by subject. Two indexes are included for ease of reference: one, an author index; the other, a topical index.

  8. Publications of the JPL Solar Thermal Power Systems Project 1976 Through 1985

    NASA Technical Reports Server (NTRS)

    Panda, P. (Compiler); Gray, V. (Compiler); Marsh, C. (Compiler)

    1985-01-01

    Bibliographical listings are documentation products associated with the Solar Thermal Power Systems Project carried out by the Jet Propulsion Laboratory from 1976 to 1986. Documents are categorized as conference and journal papers, JPL external reports, JPL internal reports, or contractor reports (i.e., deliverable documents produced under contract to JPL). Alphabetical listings by titles are used in the bibliography itself to facilitate location of the document by subject. Two indexes are included for ease of reference; an author index; and a topical index.

  9. Researching from within: External and Internal Ethical Engagement

    ERIC Educational Resources Information Center

    Floyd, Alan; Arthur, Linet

    2012-01-01

    This article examines the superficial and deep ethical and moral dilemmas confronting "insider" researchers, which we term external and internal ethical engagement. External ethical engagement refers to the traditional, easily identifiable ethical issues that insider researchers attend to by submitting their application for ethical approval to…

  10. Capillarity ion concentration polarization as spontaneous desalting mechanism.

    PubMed

    Park, Sungmin; Jung, Yeonsu; Son, Seok Young; Cho, Inhee; Cho, Youngrok; Lee, Hyomin; Kim, Ho-Young; Kim, Sung Jae

    2016-04-01

    To overcome a world-wide water shortage problem, numerous desalination methods have been developed with state-of-the-art power efficiency. Here we propose a spontaneous desalting mechanism referred to as the capillarity ion concentration polarization. An ion-depletion zone is spontaneously formed near a nanoporous material by the permselective ion transportation driven by the capillarity of the material, in contrast to electrokinetic ion concentration polarization which achieves the same ion-depletion zone by an external d.c. bias. This capillarity ion concentration polarization device is shown to be capable of desalting an ambient electrolyte more than 90% without any external electrical power sources. Theoretical analysis for both static and transient conditions are conducted to characterize this phenomenon. These results indicate that the capillarity ion concentration polarization system can offer unique and economical approaches for a power-free water purification system.

  11. The Internal/External Frame of Reference of Academic Self-Concept: Extension to a Foreign Language and the Role of Language of Instruction

    ERIC Educational Resources Information Center

    Xu, Man K.; Marsh, Herbert W.; Hau, Kit-Tai; Ho, Irene T.; Morin, Alexandre J. S.; Abduljabbar, Adel S.

    2013-01-01

    The internal/external frame of reference (I/E) model (Marsh, 1986) posits that the effects of contrasting math and verbal domains of achievement are positive for matching academic self-concepts (ASCs) but negative for nonmatching ASCs (i.e., math achievement on verbal ASC; verbal achievement on math ASC). We extend the classic I/E model by…

  12. The Longitudinal Interplay of Students' Academic Self-Concepts and Achievements within and across Domains: Replicating and Extending the Reciprocal Internal/External Frame of Reference Model

    ERIC Educational Resources Information Center

    Niepel, Christoph; Brunner, Martin; Preckel, Franzis

    2014-01-01

    Students' cognitive and motivational profiles have a large impact on their academic careers. The development of such profiles can partly be explained by the reciprocal internal/external frame of reference model (RI/E model). The RI/E model predicts positive and negative longitudinal effects between academic self-concepts and achievements within…

  13. Space-Based Observations of Satellites From the MOST Microsatellite

    DTIC Science & Technology

    2006-11-01

    error estimate for these observations. To perform differential photometry, reference magnitudes for the background stars are needed. The Hubble Guide ...22 6.3 External Calibration References ..................................................................... 23 6.4 Post...32 10. References

  14. Design Technology of Advanced Composites.

    DTIC Science & Technology

    1982-11-01

    Communications A.146 Figure 2.-- Conceptual Structure of the Fundamental Protocol Building Block A.147 Figure 3.--External Interactions Associated with a...compatibility between 1544 and 2048 kbit/s system. Annex 5 contains a description of the proposed framwork for distribution to other Study Groups. Some of...are conceptual configurations useful in identifying various possible arrangements to an ISDN. Two concepts are used in defining reference configurations

  15. User Guide to the PDS Dataset for the Cassini Composite Infrared Spectrometer (CIRS)

    NASA Technical Reports Server (NTRS)

    Nixon, Conor A.; Kaelberer, Monte S.; Gorius, Nicolas

    2012-01-01

    This User Guide to the Cassini Composite Infrared Spectrometer (CIRS) has been written with two communities in mind. First and foremost, scientists external to the Cassini Project who seek to use the CIRS data as archived in the Planetary Data System (PDS). In addition, it is intended to be a comprehensive reference guide for those internal to the CIRS team.

  16. Aspheric and freeform surfaces metrology with software configurable optical test system: a computerized reverse Hartmann test

    NASA Astrophysics Data System (ADS)

    Su, Peng; Khreishi, Manal A. H.; Su, Tianquan; Huang, Run; Dominguez, Margaret Z.; Maldonado, Alejandro; Butel, Guillaume; Wang, Yuhao; Parks, Robert E.; Burge, James H.

    2014-03-01

    A software configurable optical test system (SCOTS) based on deflectometry was developed at the University of Arizona for rapidly, robustly, and accurately measuring precision aspheric and freeform surfaces. SCOTS uses a camera with an external stop to realize a Hartmann test in reverse. With the external camera stop as the reference, a coordinate measuring machine can be used to calibrate the SCOTS test geometry to a high accuracy. Systematic errors from the camera are carefully investigated and controlled. Camera pupil imaging aberration is removed with the external aperture stop. Imaging aberration and other inherent errors are suppressed with an N-rotation test. The performance of the SCOTS test is demonstrated with the measurement results from a 5-m-diameter Large Synoptic Survey Telescope tertiary mirror and an 8.4-m diameter Giant Magellan Telescope primary mirror. The results show that SCOTS can be used as a large-dynamic-range, high-precision, and non-null test method for precision aspheric and freeform surfaces. The SCOTS test can achieve measurement accuracy comparable to traditional interferometric tests.

  17. Generating Artificial Reference Images for Open Loop Correlation Wavefront Sensors

    NASA Astrophysics Data System (ADS)

    Townson, M. J.; Love, G. D.; Saunter, C. D.

    2018-05-01

    Shack-Hartmann wavefront sensors for both solar and laser guide star adaptive optics (with elongated spots) need to observe extended objects. Correlation techniques have been successfully employed to measure the wavefront gradient in solar adaptive optics systems and have been proposed for laser guide star systems. In this paper we describe a method for synthesising reference images for correlation Shack-Hartmann wavefront sensors with a larger field of view than individual sub-apertures. We then show how these supersized reference images can increase the performance of correlation wavefront sensors in regimes where large relative shifts are induced between sub-apertures, such as those observed in open-loop wavefront sensors. The technique we describe requires no external knowledge outside of the wavefront-sensor images, making it available as an entirely "software" upgrade to an existing adaptive optics system. For solar adaptive optics we show the supersized reference images extend the magnitude of shifts which can be accurately measured from 12% to 50% of the field of view of a sub-aperture and in laser guide star wavefront sensors the magnitude of centroids that can be accurately measured is increased from 12% to 25% of the total field of view of the sub-aperture.

  18. External skeletal robusticity of children and adolescents - European references from birth to adulthood and international comparisons.

    PubMed

    Mumm, Rebekka; Godina, Elena; Koziel, Slawomir; Musalek, Martin; Sedlak, Petr; Wittwer-Backofen, Ursula; Hesse, Volker; Dasgupta, Parasmani; Henneberg, Maciej; Scheffler, Christiane

    2018-06-11

    Background: In our modern world, the way of life in nutritional and activity behaviour has changed. As a consequence, parallel trends of an epidemic of overweight and a decline in external skeletal robusticity are observed in children and adolescents. Aim: We aim to develop reference centiles for external skeletal robusticity of European girls and boys aged 0 to 18 years using the Frame Index as an indicator and identify population specific age-related patterns. Methods: We analysed cross-sectional & longitudinal data on body height and elbow breadth of boys and girls from Europe (0-18 years, n = 41.679), India (7-18 years, n = 3.297) and South Africa (3-18 years, n = 4.346). As an indicator of external skeletal robusticity Frame Index after Frisancho (1990) was used. We developed centiles for boys and girls using the LMS-method and its extension. Results: Boys have greater external skeletal robusticity than girls. Whereas in girls Frame Index decreases continuously during growth, an increase of Frame Index from 12 to 16 years in European boys can be observed. Indian and South African boys are almost similar in Frame Index to European boys. In girls, the pattern is slightly different. Whereas South African girls are similar to European girls, Indian girls show a lesser external skeletal robusticity. Conclusion: Accurate references for external skeletal robusticity are needed to evaluate if skeletal development is adequate per age. They should be used to monitor effects of changes in way of life and physical activity levels in children and adolescents to avoid negative health outcomes like osteoporosis and arthrosis.

  19. Preliminary characterisation of new glass reference materials (GSA-1G, GSC-1G, GSD-1G and GSE-1G) by laser ablation-inductively coupled plasma-mass spectrometry using 193 nm, 213 nm and 266 nm wavelengths

    USGS Publications Warehouse

    Guillong, M.; Hametner, K.; Reusser, E.; Wilson, S.A.; Gunther, D.

    2005-01-01

    New glass reference materials GSA-1G, GSC-1G, GSD-1G and GSE-1G have been characterised using a prototype solid state laser ablation system capable of producing wavelengths of 193 nm, 213 nm and 266 nm. This system allowed comparison of the effects of different laser wavelengths under nearly identical ablation and ICP operating conditions. The wavelengths 213 nm and 266 nm were also used at higher energy densities to evaluate the influence of energy density on quantitative analysis. In addition, the glass reference materials were analysed using commercially available 266 nm Nd:YAG and 193 nm ArF excimer lasers. Laser ablation analysis was carried out using both single spot and scanning mode ablation. Using laser ablation ICP-MS, concentrations of fifty-eight elements were determined with external calibration to the NIST SRM 610 glass reference material. Instead of applying the more common internal standardisation procedure, the total concentration of all element oxide concentrations was normalised to 100%. Major element concentrations were compared with those determined by electron microprobe. In addition to NIST SRM 610 for external calibration, USGS BCR-2G was used as a more closely matrix-matched reference material in order to compare the effect of matrix-matched and non matrix-matched calibration on quantitative analysis. The results show that the various laser wavelengths and energy densities applied produced similar results, with the exception of scanning mode ablation at 266 nm without matrix-matched calibration where deviations up to 60% from the average were found. However, results acquired using a scanning mode with a matrix-matched calibration agreed with results obtained by spot analysis. The increased abundance of large particles produced when using a scanning ablation mode with NIST SRM 610, is responsible for elemental fractionation effects caused by incomplete vaporisation of large particles in the ICP.

  20. The environmental zero-point problem in evolutionary reaction norm modeling.

    PubMed

    Ergon, Rolf

    2018-04-01

    There is a potential problem in present quantitative genetics evolutionary modeling based on reaction norms. Such models are state-space models, where the multivariate breeder's equation in some form is used as the state equation that propagates the population state forward in time. These models use the implicit assumption of a constant reference environment, in many cases set to zero. This zero-point is often the environment a population is adapted to, that is, where the expected geometric mean fitness is maximized. Such environmental reference values follow from the state of the population system, and they are thus population properties. The environment the population is adapted to, is, in other words, an internal population property, independent of the external environment. It is only when the external environment coincides with the internal reference environment, or vice versa, that the population is adapted to the current environment. This is formally a result of state-space modeling theory, which is an important theoretical basis for evolutionary modeling. The potential zero-point problem is present in all types of reaction norm models, parametrized as well as function-valued, and the problem does not disappear when the reference environment is set to zero. As the environmental reference values are population characteristics, they ought to be modeled as such. Whether such characteristics are evolvable is an open question, but considering the complexity of evolutionary processes, such evolvability cannot be excluded without good arguments. As a straightforward solution, I propose to model the reference values as evolvable mean traits in their own right, in addition to other reaction norm traits. However, solutions based on an evolvable G matrix are also possible.

  1. Semi-analytical integration of the Earth's precession-nutation based on the GCRS coordinates of the CIP unit vector

    NASA Astrophysics Data System (ADS)

    Capitaine, N.; Folgueira, M.

    2012-12-01

    In a previous paper (Capitaine et al. 2006), referred here as Paper I, we demonstrated the possibility of integrating the Earth's rotational motion in terms of the coordinates (X, Y ) of the celestial intermediate pole (CIP) unit vector in the Geocentric celestial reference system (GCRS). Here, we report on the approach that has been followed for solving the equations in the case of an axially symmetric rigid Earth and the semi-analytical (X, Y ) solution obtained from the expression of the external torque acting on the Earth derived from the most complete semi-analytical solutions for the Earth, Moon and planets.

  2. External ophthalmomyiasis presenting to an emergency department: corneal findings as a sign of Oestrus ovis.

    PubMed

    Gholamhossein, Yaghoubi; Behrouz, Heydari

    2013-10-01

    This study aims to determine the frequency of opthalmyomyiasis externa and the ocular findings of disease in Southern Khorasan. All patients referred to the emergency department of Valiaser hospital during the year 2011 with external ophthalmomyiasis were enrolled in this study. The diagnosis of external ophthalmomyiasis was made according to clinical findings and the presence of Oestrus ovis larvae. There were 18 cases of external ophthalmomyiasis in the emergency department of Valiaser hospital in 2011. Most cases had the common signs and symptoms of allergic conjunctivitis, except for three males who were referred with respective complaints of red eye, foreign body sensation, and swelling around the eyelids after contact injury the previous day; corneal infiltration was present in three cases. The visual acuity among the three cases that had peripheral corneal involvement was 20 / 30 in both eyes. The bulbar conjunctiva showed chemosis in all cases and a ropy pattern discharge that was clinically compatible with external ophthalmomyiasis. However, in one case, microscopic slit lamp examination did not show Oestrus ovis larvae. The frequency of external ophthalmomyiasis was high in this region. Although external ophthalmomyiasis usually manifests as allergic conjunctivitis, coronary-like corneal infiltration may be considered in the differential diagnosis of external ophthalmomyiasis or toxic insult.

  3. External Ophthalmomyiasis Presenting to an Emergency Department: Corneal Findings as a Sign of Oestrus ovis

    PubMed Central

    Behrouz, Heydari

    2013-01-01

    Purpose This study aims to determine the frequency of opthalmyomyiasis externa and the ocular findings of disease in Southern Khorasan. Methods All patients referred to the emergency department of Valiaser hospital during the year 2011 with external ophthalmomyiasis were enrolled in this study. The diagnosis of external ophthalmomyiasis was made according to clinical findings and the presence of Oestrus ovis larvae. Results There were 18 cases of external ophthalmomyiasis in the emergency department of Valiaser hospital in 2011. Most cases had the common signs and symptoms of allergic conjunctivitis, except for three males who were referred with respective complaints of red eye, foreign body sensation, and swelling around the eyelids after contact injury the previous day; corneal infiltration was present in three cases. The visual acuity among the three cases that had peripheral corneal involvement was 20 / 30 in both eyes. The bulbar conjunctiva showed chemosis in all cases and a ropy pattern discharge that was clinically compatible with external ophthalmomyiasis. However, in one case, microscopic slit lamp examination did not show Oestrus ovis larvae. Conclusions The frequency of external ophthalmomyiasis was high in this region. Although external ophthalmomyiasis usually manifests as allergic conjunctivitis, coronary-like corneal infiltration may be considered in the differential diagnosis of external ophthalmomyiasis or toxic insult. PMID:24082771

  4. Technique for long and absolute distance measurement based on laser pulse repetition frequency sweeping

    NASA Astrophysics Data System (ADS)

    Castro Alves, D.; Abreu, Manuel; Cabral, A.; Jost, Michael; Rebordão, J. M.

    2017-11-01

    In this work we present a technique to perform long and absolute distance measurements based on mode-locked diode lasers. Using a Michelson interferometer, it is possible to produce an optical cross-correlation between laser pulses of the reference arm with the pulses from the measurement arm, adjusting externally their degree of overlap either changing the pulse repetition frequency (PRF) or the position of the reference arm mirror for two (or more) fixed frequencies. The correlation of the travelling pulses for precision distance measurements relies on ultra-short pulse durations, as the uncertainty associated to the method is dependent on the laser pulse width as well as on a highly stable PRF. Mode-locked Diode lasers are a very appealing technology for its inherent characteristics, associated to compactness, size and efficiency, constituting a positive trade-off with regard to other mode-locked laser sources. Nevertheless, main current drawback is the non-availability of frequency-stable laser diodes. The laser used is a monolithic mode-locked semiconductor quantum-dot (QD) laser. The laser PRF is locked to an external stabilized RF reference. In this work we will present some of the preliminary results and discuss the importance of the requirements related to laser PRF stability in the final metrology system accuracy.

  5. Conceptualizing belonging.

    PubMed

    Mahar, Alyson L; Cobigo, Virginie; Stuart, Heather

    2013-06-01

    To develop a transdisciplinary conceptualization of social belonging that could be used to guide measurement approaches aimed at evaluating the effectiveness of community-based programs for people with disabilities. We conducted a narrative, scoping review of peer reviewed English language literature published between 1990 and July 2011 using multiple databases, with "sense of belonging" as a key search term. The search engine ranked articles for relevance to the search strategy. Articles were searched in order until theoretical saturation was reached. We augmented this search strategy by reviewing reference lists of relevant papers. Theoretical saturation was reached after 40 articles; 22 of which were qualitative accounts. We identified five intersecting themes: subjectivity; groundedness to an external referent; reciprocity; dynamism and self-determination. We define a sense of belonging as a subjective feeling of value and respect derived from a reciprocal relationship to an external referent that is built on a foundation of shared experiences, beliefs or personal characteristics. These feelings of external connectedness are grounded to the context or referent group, to whom one chooses, wants and feels permission to belong. This dynamic phenomenon may be either hindered or promoted by complex interactions between environmental and personal factors.

  6. Low-cost, digital lock-in module with external reference for coating glass transmission/reflection spectrophotometer

    NASA Astrophysics Data System (ADS)

    Alonso, R.; Villuendas, F.; Borja, J.; Barragán, L. A.; Salinas, I.

    2003-05-01

    A versatile, low-cost, digital signal processor (DSP) based lock-in module with external reference is described. This module is used to implement an industrial spectrophotometer for measuring spectral transmission and reflection of automotive and architectonic coating glasses over the ultraviolet, visible and near-infrared wavelength range. The light beams are modulated with an optical chopper. A digital phase-locked loop (DPLL) is used to lock the lock-in to the chop frequency. The lock-in rejects the ambient radiation and permits the spectrophotometer to work in the presence of ambient light. The algorithm that implements the dual lock-in and the DPLL in the DSP56002 evaluation module from Motorola is described. The use of a DSP allows implementation of the lock-in and DPLL by software, which gives flexibility and programmability to the system. Lock-in module cost, under 300 euro, is an important parameter taking into account that two modules are used in the system. Besides, the algorithms implemented in this DSP can be directly implemented in the latest DSP generations. The DPLL performance and the spectrophotometer are characterized. Capture and lock DPLL ranges have been measured and checked to be greater than the chop frequency drifts. The lock-in measured frequency response shows that the lock-in performs as theoretically predicted.

  7. The effect of contaminated sediments on fecundity of the brown bullhead in three Lake Erie tributaries

    USGS Publications Warehouse

    Lesko, Lynn T.; Smith, Stephen B.; Blouin, Marc A.

    1996-01-01

    Female brown bullhead (Ameiurus nebulosus) were collected from three Lake Erie tributaries (Ohio) from 8 to 25 May 1989, to determine the effects of contaminated sediments on reproductive potentials. Fish obtained from the Black and Cuyahoga rivers, which contain sediments with elevated concentrations of metals, PCBs, and PAHs, were compared with fish collected in Mud Brook, a tributary of the Huron River, which was selected as our reference site. Fecundity, egg diameter, fish length and weight, and the presence of external abnormalities were recorded for each fish. Brown bullhead from the contaminated sites were larger then those from the reference site and fecundity was significantly (P < 0.05) different in all three river systems. Those from the most polluted river (Cuyahoga River) had the greatest number of eggs per individual female. The high frequency of external abnormalities observed on brown bullhead from the contaminated sites did not appear to have a detrimental influence on fecundity. These results suggest that fecundity of the brown bullhead was not adversely affected in ecosystems altered by the presence of contaminated sediments. Increased fecundity of the brown bullhead from impacted rivers may be the result of reduced competition for an abundant invertebrate food source and limited predation by other fish species whose numbers are largely depleted in these degraded systems.

  8. System and method for tuning adjusting the central frequency of a laser while maintaining frequency stabilization to an external reference

    NASA Technical Reports Server (NTRS)

    Livas, Jeffrey (Inventor); Thorpe, James I. (Inventor); Numata, Kenji (Inventor)

    2011-01-01

    A method and system for stabilizing a laser to a frequency reference with an adjustable offset. The method locks a sideband signal generated by passing an incoming laser beam through the phase modulator to a frequency reference, and adjusts a carrier frequency relative to the locked sideband signal by changing a phase modulation frequency input to the phase modulator. The sideband signal can be a single sideband (SSB), dual sideband (DSB), or an electronic sideband (ESB) signal. Two separate electro-optic modulators can produce the DSB signal. The two electro-optic modulators can be a broadband modulator and a resonant modulator. With a DSB signal, the method can introduce two sinusoidal phase modulations at the phase modulator. With ESB signals, the method can further drive the optical phase modulator with an electrical signal with nominal frequency OMEGA(sub 1) that is phase modulated at a frequency OMEGA(sub 2)

  9. Comparing pharmaceutical pricing and reimbursement policies in Croatia to the European Union Member States

    PubMed Central

    Vogler, Sabine; Habl, Claudia; Bogut, Martina; Vončina, Luka

    2011-01-01

    Aim To perform a comparative analysis of the pharmaceutical pricing and reimbursement systems in Croatia and the 27 European Union (EU) Member States. Methods Knowledge about the pharmaceutical systems in Croatia and the 27 EU Member States was acquired by literature review and primary research with stakeholders. Results Pharmaceutical prices are controlled at all levels in Croatia, which is also the case in 21 EU Member States. Like many EU countries, Croatia also applies external price referencing, ie, compares prices with other countries. While the wholesale remuneration by a statutorily regulated linear mark-up is applied in Croatia and in several EU countries, the pharmacy compensation for dispensing reimbursable medicines in the form of a flat rate service fee in Croatia is rare among EU countries, which usually apply a linear or regressive pharmacy mark-up scheme. Like in most EU countries, the Croatian Social Insurance reimburses specific medicines at 100%, whereas patients are charged co-payments for other reimbursable medicines. Criteria for reimbursement include the medicine’s importance from the public health perspective, its therapeutic value, and relative effectiveness. In Croatia and in many EU Member States, reimbursement is based on a reference price system. Conclusion The Croatian pharmaceutical system is similar to those in the EU Member States. Key policies, like external price referencing and reference price systems, which have increasingly been introduced in EU countries are also applied in Croatia and serve the same purpose: to ensure access to medicines while containing public pharmaceutical expenditure. PMID:21495202

  10. The twilight of the training analysis system.

    PubMed

    Kernberg, Otto F

    2014-04-01

    This paper briefly reviews challenges to psychoanalysis at this time, including those derived from both external, societal origins and internal psychoanalytic problems. It focuses attention on serious conflicts around psychoanalytic education, and refers to the training analysis system as a central problem determining fundamental constraints on present-day psychoanalytic education. These constraints are examined in some detail, and the general advantages and disadvantages of the training analysis system are outlined. The effects of all these dynamics on the administrative organization of the American Psychoanalytic Association are explored, and a proposal for a fundamental reorganization of our educational system to resolve the correspondent problems is outlined.

  11. Working fluid selection for space-based two-phase heat transport systems

    NASA Technical Reports Server (NTRS)

    Mclinden, Mark O.

    1988-01-01

    The working fluid for externally-mounted, space-based two-phase heat transport systems is considered. A sequence of screening criteria involving freezing and critical point temperatures and latent heat of vaporization and vapor density are applied to a data base of 860 fluids. The thermal performance of the 52 fluids which pass this preliminary screening are then ranked according to their impact on the weight of a reference system. Upon considering other nonthermal criteria (flammability, toxicity, and chemical stability) a final set of 10 preferred fluids is obtained. The effects of variations in system parameters is investigated for these 10 fluids by means of a factorial design.

  12. Skylab Rescue Space Vehicle OAT No. 1 Plugs in Test

    NASA Technical Reports Server (NTRS)

    Jevitt, S. J.

    1973-01-01

    A test is described which demonstrates the compatibility of the Skylab Rescue Space Vehicle systems, the ground support equipment, and off-site support facilities by proceeding through a simulated launch countdown, liftoff, and flight. The functions of propellant loading, umbilical ejection, holddown arm release, service arm retraction, liftoff, and inflight separation are simulated. An external power source supplies transfer power to internal, and instrument unit commands are simulated by the digital command system. The test outline is presented along with a list of references, intercommunications information, radio frequency matrix, and interface control chart.

  13. Computational models for the analysis of three-dimensional internal and exhaust plume flowfields

    NASA Technical Reports Server (NTRS)

    Dash, S. M.; Delguidice, P. D.

    1977-01-01

    This paper describes computational procedures developed for the analysis of three-dimensional supersonic ducted flows and multinozzle exhaust plume flowfields. The models/codes embodying these procedures cater to a broad spectrum of geometric situations via the use of multiple reference plane grid networks in several coordinate systems. Shock capturing techniques are employed to trace the propagation and interaction of multiple shock surfaces while the plume interface, separating the exhaust and external flows, and the plume external shock are discretely analyzed. The computational grid within the reference planes follows the trace of streamlines to facilitate the incorporation of finite-rate chemistry and viscous computational capabilities. Exhaust gas properties consist of combustion products in chemical equilibrium. The computational accuracy of the models/codes is assessed via comparisons with exact solutions, results of other codes and experimental data. Results are presented for the flows in two-dimensional convergent and divergent ducts, expansive and compressive corner flows, flow in a rectangular nozzle and the plume flowfields for exhausts issuing out of single and multiple rectangular nozzles.

  14. Headspace solid phase microextraction--GC/C-IRMS for delta13CVPDB measurements of mono-aromatic hydrocarbons using EA-IRMS calibration.

    PubMed

    Ebongué, Véronique Woule; Geypens, Benny; Berglund, Michael; Taylor, Philip

    2009-03-01

    This work aims at comparing the delta(13)C(VPDB) of mono-aromatic hydrocarbons benzene, toluene, ethylbenzene and xylene isomers (BTEX) measured by elemental analyser (EA)-isotope ratio mass spectrometer (IRMS) with the delta(13)C(VPDB) measured on the same compounds by headspace solid phase microextraction - GC/C-IRMS (hSPME - GC/C-IRMS) with the final goal of using these compounds as internal standards on the latter system. The EA-IRMS measurements were done using calcium and lithium carbonate isotopic reference materials: NBS19 and L-SVEC for establishing the delta(13)C(VPDB) scale. The EA-IRMS measurements with helium dilution of a set of five reference materials (USGS40, USGS41, IAEA-CH-6, IAEA-CH-3 and IAEA-601) show systematic bias of 1 per thousand relative to their assigned values. This bias due to the dilution mechanism in the used ConfloII interface device could not be avoided. As the selected hydrocarbons: BTEX could not be analysed by EA-IRMS without helium dilution, their delta(13)C(VPDB) must be corrected from this observed bias using an external calibration. The CO(2) gas calibrated using EA-IRMS without helium dilution, was used as an in-house reference for the delta(13)C(VPDB) measurements of the BTEX by the hSPME - GC/C-IRMS system. The comparison made between the delta(13)C(VPDB) measured on the same BTEX compounds by EA-IRMS (with external calibration) and by hSPME - GC/C-IRMS techniques showed good agreement.

  15. Consistency properties of chaotic systems driven by time-delayed feedback

    NASA Astrophysics Data System (ADS)

    Jüngling, T.; Soriano, M. C.; Oliver, N.; Porte, X.; Fischer, I.

    2018-04-01

    Consistency refers to the property of an externally driven dynamical system to respond in similar ways to similar inputs. In a delay system, the delayed feedback can be considered as an external drive to the undelayed subsystem. We analyze the degree of consistency in a generic chaotic system with delayed feedback by means of the auxiliary system approach. In this scheme an identical copy of the nonlinear node is driven by exactly the same signal as the original, allowing us to verify complete consistency via complete synchronization. In the past, the phenomenon of synchronization in delay-coupled chaotic systems has been widely studied using correlation functions. Here, we analytically derive relationships between characteristic signatures of the correlation functions in such systems and unequivocally relate them to the degree of consistency. The analytical framework is illustrated and supported by numerical calculations of the logistic map with delayed feedback for different replica configurations. We further apply the formalism to time series from an experiment based on a semiconductor laser with a double fiber-optical feedback loop. The experiment constitutes a high-quality replica scheme for studying consistency of the delay-driven laser and confirms the general theoretical results.

  16. The discriminatory capability of existing scores to predict advanced colorectal neoplasia: a prospective colonoscopy study of 5,899 screening participants.

    PubMed

    Wong, Martin C S; Ching, Jessica Y L; Ng, Simpson; Lam, Thomas Y T; Luk, Arthur K C; Wong, Sunny H; Ng, Siew C; Ng, Simon S M; Wu, Justin C Y; Chan, Francis K L; Sung, Joseph J Y

    2016-02-03

    We evaluated the performance of seven existing risk scoring systems in predicting advanced colorectal neoplasia in an asymptomatic Chinese cohort. We prospectively recruited 5,899 Chinese subjects aged 50-70 years in a colonoscopy screening programme(2008-2014). Scoring systems under evaluation included two scoring tools from the US; one each from Spain, Germany, and Poland; the Korean Colorectal Screening(KCS) scores; and the modified Asia Pacific Colorectal Screening(APCS) scores. The c-statistics, sensitivity, specificity, positive predictive values(PPVs), and negative predictive values(NPVs) of these systems were evaluated. The resources required were estimated based on the Number Needed to Screen(NNS) and the Number Needed to Refer for colonoscopy(NNR). Advanced neoplasia was detected in 364 (6.2%) subjects. The German system referred the least proportion of subjects (11.2%) for colonoscopy, whilst the KCS scoring system referred the highest (27.4%). The c-statistics of all systems ranged from 0.56-0.65, with sensitivities ranging from 0.04-0.44 and specificities from 0.74-0.99. The modified APCS scoring system had the highest c-statistics (0.65, 95% C.I. 0.58-0.72). The NNS (12-19) and NNR (5-10) were similar among the scoring systems. The existing scoring systems have variable capability to predict advanced neoplasia among asymptomatic Chinese subjects, and further external validation should be performed.

  17. Research on Robust Control Strategies for VSC-HVDC

    NASA Astrophysics Data System (ADS)

    Zhu, Kaicheng; Bao, Hai

    2018-01-01

    In the control system of VSC-HVDC, the phase locked loop provides phase signals to voltage vector control and trigger pulses to generate the required reference phase. The PLL is a typical second-order system. When the system is in unstable state, it will oscillate, make the trigger angle shift, produce harmonic, and make active power and reactive power coupled. Thus, considering the external disturbances introduced by the PLL in VSC-HVDC control system, the parameter perturbations of the controller and the model uncertainties, a H∞ robust controller of mixed sensitivity optimization problem is designed by using the Hinf function provided by the robust control toolbox. Then, compare it with the proportional integral controller through the MATLAB simulation experiment. By contrast, when the H∞ robust controller is added, active and reactive power of the converter station can track the change of reference values more accurately and quickly, and reduce overshoot. When the step change of active and reactive power occurs, mutual influence is reduced and better independent regulation is achieved.

  18. Overview of external reference pricing systems in Europe

    PubMed Central

    Rémuzat, Cécile; Urbinati, Duccio; Mzoughi, Olfa; El Hammi, Emna; Belgaied, Wael; Toumi, Mondher

    2015-01-01

    Background and objectives External reference pricing (ERP) is a price regulation tool widely used by policy makers in the European Union (EU) Member States (MS) to contain drug cost, although in theory, it may contribute to modulate prices up and down. The objective of this article was to summarise and discuss the main findings of part of a large project conducted for the European Commission (‘External reference pricing of medicinal products: simulation-based considerations for cross-country coordination’; see www.ec.europa.eu/health/healthcare/docs/erp_reimbursement_medicinal_products_en.pdf) that aimed to provide an overview of ERP systems, both on processes and potential issues in 31 European countries (28 EU MS, Iceland, Norway, and Switzerland). Methods A systematic structured literature review was conducted to identify and characterise the use of ERP in the selected countries, to describe its impact on the prices of pharmaceuticals, and to discuss the possible cross-country coordination issues in EU MS. This research was complemented with a consultation of competent authorities’ and international organisations’ representatives to address the main issues or uncertainties identified through the literature review. Results All selected countries applied ERP, except the United Kingdom and Sweden. Twenty-three countries used ERP as the main systematic criterion for pricing. In the majority of European countries, ERP was based on legislated pricing rules with different levels of accuracy. ERP was applied either for all marketed drugs or for specific categories of medicines; it was mainly used for publicly reimbursed medicines. The number of reference countries included in the basket varied from 1 to 31. There was a great variation in the calculation methods used to compute the price; 15 countries used the average price, 7 countries used the lowest price, and 7 countries used other calculation methods. Reported limitations of ERP application included the lack of reliable sources of price information, price heterogeneity, exchange rate volatility, and hidden discounts. Spill-over effect and downward price convergence have often been mentioned as ERP's consequences leading to pricing strategies from pharmaceutical companies. Conclusion While ERP is widely used in Europe, processes and availability of price information vary from one country to another, thus limiting ERP implementation. Furthermore, ERP spill-over effect is a major concern of pharmaceutical firms leading to implementation of the so-called ‘launch sequence strategies’. PMID:27123181

  19. Overview of external reference pricing systems in Europe.

    PubMed

    Rémuzat, Cécile; Urbinati, Duccio; Mzoughi, Olfa; El Hammi, Emna; Belgaied, Wael; Toumi, Mondher

    2015-01-01

    External reference pricing (ERP) is a price regulation tool widely used by policy makers in the European Union (EU) Member States (MS) to contain drug cost, although in theory, it may contribute to modulate prices up and down. The objective of this article was to summarise and discuss the main findings of part of a large project conducted for the European Commission ('External reference pricing of medicinal products: simulation-based considerations for cross-country coordination'; see www.ec.europa.eu/health/healthcare/docs/erp_reimbursement_medicinal_products_en.pdf) that aimed to provide an overview of ERP systems, both on processes and potential issues in 31 European countries (28 EU MS, Iceland, Norway, and Switzerland). A systematic structured literature review was conducted to identify and characterise the use of ERP in the selected countries, to describe its impact on the prices of pharmaceuticals, and to discuss the possible cross-country coordination issues in EU MS. This research was complemented with a consultation of competent authorities' and international organisations' representatives to address the main issues or uncertainties identified through the literature review. All selected countries applied ERP, except the United Kingdom and Sweden. Twenty-three countries used ERP as the main systematic criterion for pricing. In the majority of European countries, ERP was based on legislated pricing rules with different levels of accuracy. ERP was applied either for all marketed drugs or for specific categories of medicines; it was mainly used for publicly reimbursed medicines. The number of reference countries included in the basket varied from 1 to 31. There was a great variation in the calculation methods used to compute the price; 15 countries used the average price, 7 countries used the lowest price, and 7 countries used other calculation methods. Reported limitations of ERP application included the lack of reliable sources of price information, price heterogeneity, exchange rate volatility, and hidden discounts. Spill-over effect and downward price convergence have often been mentioned as ERP's consequences leading to pricing strategies from pharmaceutical companies. While ERP is widely used in Europe, processes and availability of price information vary from one country to another, thus limiting ERP implementation. Furthermore, ERP spill-over effect is a major concern of pharmaceutical firms leading to implementation of the so-called 'launch sequence strategies'.

  20. H∞ output tracking control of uncertain and disturbed nonlinear systems based on neural network model

    NASA Astrophysics Data System (ADS)

    Li, Chengcheng; Li, Yuefeng; Wang, Guanglin

    2017-07-01

    The work presented in this paper seeks to address the tracking problem for uncertain continuous nonlinear systems with external disturbances. The objective is to obtain a model that uses a reference-based output feedback tracking control law. The control scheme is based on neural networks and a linear difference inclusion (LDI) model, and a PDC structure and H∞ performance criterion are used to attenuate external disturbances. The stability of the whole closed-loop model is investigated using the well-known quadratic Lyapunov function. The key principles of the proposed approach are as follows: neural networks are first used to approximate nonlinearities, to enable a nonlinear system to then be represented as a linearised LDI model. An LMI (linear matrix inequality) formula is obtained for uncertain and disturbed linear systems. This formula enables a solution to be obtained through an interior point optimisation method for some nonlinear output tracking control problems. Finally, simulations and comparisons are provided on two practical examples to illustrate the validity and effectiveness of the proposed method.

  1. Sensorless H∞ speed-tracking synthesis for surface-mount permanent magnet synchronous motor.

    PubMed

    Ramírez-Villalobos, Ramón; Aguilar, Luis T; Coria, Luis N

    2017-03-01

    In this paper, a sensorless speed tracking control is proposed for a surface-mount permanent magnet synchronous motor by using a nonlinear H ∞ -controller via stator currents measurements for feedback. An output feedback nonlinear H ∞ -controller was designed such that the undisturbed system is uniformly asymptotically stable around the desired speed reference, while also the effects of external vanishing and non-vanishing disturbances, noise, and input backlash were attenuated locally. The rotor position was calculated from the causal dynamic output feedback compensator and from the desired speed reference. The existence of the proper solutions of the perturbed differential Riccati equations ensures stabilizability and detectability of the control system. The efficiency of the proposed sensorless controller was supported by numerical simulations. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.

  2. Statistical foundations of liquid-crystal theory

    PubMed Central

    Seguin, Brian; Fried, Eliot

    2013-01-01

    We develop a mechanical theory for systems of rod-like particles. Central to our approach is the assumption that the external power expenditure for any subsystem of rods is independent of the underlying frame of reference. This assumption is used to derive the basic balance laws for forces and torques. By considering inertial forces on par with other forces, these laws hold relative to any frame of reference, inertial or noninertial. Finally, we introduce a simple set of constitutive relations to govern the interactions between rods and find restrictions necessary and sufficient for these laws to be consistent with thermodynamics. Our framework provides a foundation for a statistical mechanical derivation of the macroscopic balance laws governing liquid crystals. PMID:23772091

  3. An auto-locked diode laser system for precision metrology

    NASA Astrophysics Data System (ADS)

    Beica, H. C.; Carew, A.; Vorozcovs, A.; Dowling, P.; Pouliot, A.; Barron, B.; Kumarakrishnan, A.

    2017-05-01

    We present a unique external cavity diode laser system that can be auto-locked with reference to atomic and molecular spectra. The vacuum-sealed laser head design uses an interchangeable base-plate comprised of a laser diode and optical elements that can be selected for desired wavelength ranges. The feedback light to the laser diode is provided by a narrow-band interference filter, which can be tuned from outside the laser cavity to fineadjust the output wavelength in vacuum. To stabilize the laser frequency, the digital laser controller relies either on a pattern-matching algorithm stored in memory, or on first or third derivative feedback. We have used the laser systems to perform spectroscopic studies in rubidium at 780 nm, and in iodine at 633 nm. The linewidth of the 780-nm laser system was measured to be ˜500 kHz, and we present Allan deviation measurements of the beat note and the lock stability. Furthermore, we show that the laser system can be the basis for a new class of lidar transmitters in which a temperature-stabilized fiber-Bragg grating is used to generate frequency references for on-line points of the transmitter. We show that the fiber-Bragg grating spectra can be calibrated with reference to atomic transitions.

  4. Third-generation blood pumps with mechanical noncontact magnetic bearings.

    PubMed

    Hoshi, Hideo; Shinshi, Tadahiko; Takatani, Setsuo

    2006-05-01

    This article reviews third-generation blood pumps, focusing on the magnetic-levitation (maglev) system. The maglev system can be categorized into three types: (i) external motor-driven system, (ii) direct-drive motor-driven system, and (iii) self-bearing or bearingless motor system. In the external motor-driven system, Terumo (Ann Arbor, MI, U.S.A.) DuraHeart is an example where the impeller is levitated in the axial or z-direction. The disadvantage of this system is the mechanical wear in the mechanical bearings of the external motor. In the second system, the impeller is made into the rotor of the motor, and the magnetic flux, through the external stator, rotates the impeller, while the impeller levitation is maintained through another electromagnetic system. The Berlin Heart (Berlin, Germany) INCOR is the best example of this principle where one-axis control combination with hydrodynamic force achieves high performance. In the third system, the stator core is shared by the levitation and drive coil to make it as if the bearing does not exist. Levitronix CentriMag (Zürich, Switzerland), which appeared recently, employs this concept to achieve stable and safe operation of the extracorporeal system that can last for a duration of 14 days. Experimental systems including HeartMate III (Thoratec, Woburn, MA, U.S.A.), HeartQuest (WorldHeart, Ottawa, ON, Canada), MagneVAD (Gold Medical Technologies, Valhalla, NY, U.S.A.), MiTiHeart (MiTi Heart, Albany, NY, U.S.A.), Ibaraki University's Heart (Hitachi, Japan) and Tokyo Medical and Dental University/Tokyo Institute of Technology's disposable and implantable maglev blood pumps are also reviewed. In reference to second-generation blood pumps, such as the Jarvik 2000 (Jarvik Heart, New York, NY, U.S.A.), which is showing remarkable achievement, a question is raised whether a complicated system such as the maglev system is really needed. We should pay careful attention to future clinical outcomes of the ongoing clinical trials of the second-generation devices before making any further remarks. What is best for patients is the best for everyone. We should not waste any efforts unless they are actually needed to improve the quality of life of heart-failure patients.

  5. Distributed finite-time trajectory tracking control for multiple nonholonomic mobile robots with uncertainties and external disturbances

    NASA Astrophysics Data System (ADS)

    Ou, Meiying; Sun, Haibin; Gu, Shengwei; Zhang, Yangyi

    2017-11-01

    This paper investigates the distributed finite-time trajectory tracking control for a group of nonholonomic mobile robots with time-varying unknown parameters and external disturbances. At first, the tracking error system is derived for each mobile robot with the aid of a global invertible transformation, which consists of two subsystems, one is a first-order subsystem and another is a second-order subsystem. Then, the two subsystems are studied respectively, and finite-time disturbance observers are proposed for each robot to estimate the external disturbances. Meanwhile, distributed finite-time tracking controllers are developed for each mobile robot such that all states of each robot can reach the desired value in finite time, where the desired reference value is assumed to be the trajectory of a virtual leader whose information is available to only a subset of the followers, and the followers are assumed to have only local interaction. The effectiveness of the theoretical results is finally illustrated by numerical simulations.

  6. Melinda – A custom search engine that provides access to locally-developed content using the HL7 Infobutton standard

    PubMed Central

    Wan, Yik-Ki J.; Staes, Catherine J.

    2016-01-01

    Healthcare organizations use care pathways to standardize care, but once developed, adoption rates often remain low. One challenge for usage concerns clinicians’ difficulty in accessing guidance when it is most needed. Although the HL7 ‘Infobutton Standard’ allows clinicians easier access to external references, access to locally-developed resources often requires clinicians to deviate from their normal electronic health record (EHR) workflow to use another application. To address this gap between internal and external resources, we reviewed the literature and existing practices at the University of Utah Health Care. We identify the requirements to meet the needs of a healthcare enterprise and clinicians, describe the design and development of a prototype to aggregate both internal and external resources from within or outside the EHR, and evaluated strengths and limitations of the prototype. The system is functional but not implemented in a live EHR environment. We suggest next steps and enhancements. PMID:28269964

  7. Rigorous Combination of GNSS and VLBI: How it Improves Earth Orientation and Reference Frames

    NASA Astrophysics Data System (ADS)

    Lambert, S. B.; Richard, J. Y.; Bizouard, C.; Becker, O.

    2017-12-01

    Current reference series (C04) of the International Earth Rotation and Reference Systems Service (IERS) are produced by a weighted combination of Earth orientation parameters (EOP) time series built up by combination centers of each technique (VLBI, GNSS, Laser ranging, DORIS). In the future, we plan to derive EOP from a rigorous combination of the normal equation systems of the four techniques.We present here the results of a rigorous combination of VLBI and GNSS pre-reduced, constraint-free, normal equations with the DYNAMO geodetic analysis software package developed and maintained by the French GRGS (Groupe de Recherche en GeÌodeÌsie Spatiale). The used normal equations are those produced separately by the IVS and IGS combination centers to which we apply our own minimal constraints.We address the usefulness of such a method with respect to the classical, a posteriori, combination method, and we show whether EOP determinations are improved.Especially, we implement external validations of the EOP series based on comparison with geophysical excitation and examination of the covariance matrices. Finally, we address the potential of the technique for the next generation celestial reference frames, which are currently determined by VLBI only.

  8. Oscillatory activity reflects differential use of spatial reference frames by sighted and blind individuals in tactile attention.

    PubMed

    Schubert, Jonathan T W; Buchholz, Verena N; Föcker, Julia; Engel, Andreas K; Röder, Brigitte; Heed, Tobias

    2015-08-15

    Touch can be localized either on the skin in anatomical coordinates, or, after integration with posture, in external space. Sighted individuals are thought to encode touch in both coordinate systems concurrently, whereas congenitally blind individuals exhibit a strong bias for using anatomical coordinates. We investigated the neural correlates of this differential dominance in the use of anatomical and external reference frames by assessing oscillatory brain activity during a tactile spatial attention task. The EEG was recorded while sighted and congenitally blind adults received tactile stimulation to uncrossed and crossed hands while detecting rare tactile targets at one cued hand only. In the sighted group, oscillatory alpha-band activity (8-12Hz) in the cue-target interval was reduced contralaterally and enhanced ipsilaterally with uncrossed hands. Hand crossing attenuated the degree of posterior parietal alpha-band lateralization, indicating that attention deployment was affected by external spatial coordinates. Beamforming suggested that this posture effect originated in the posterior parietal cortex. In contrast, cue-related lateralization of central alpha-band as well as of beta-band activity (16-24Hz) were unaffected by hand crossing, suggesting that these oscillations exclusively encode anatomical coordinates. In the blind group, central alpha-band activity was lateralized, but did not change across postures. The pattern of beta-band activity was indistinguishable between groups. Because the neural mechanisms for posterior alpha-band generation seem to be linked to developmental vision, we speculate that the lack of this neural mechanism in blind individuals is related to their preferred use of anatomical over external spatial codes in sensory processing. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. The Radiation, Interplanetary Shocks, and Coronal Sources (RISCS) Toolset

    NASA Technical Reports Server (NTRS)

    Zank, G. P.; Spann, James F.

    2014-01-01

    The goal of this project is to serve the needs of space system designers and operators by developing an interplanetary radiation environment model within 10 AU:Radiation, Interplanetary Shocks, and Coronal Sources (RISCS) toolset: (1) The RISCS toolset will provide specific reference environments for space system designers and nowcasting and forecasting capabilities for space system operators; (2) We envision the RISCS toolset providing the spatial and temporal radiation environment external to the Earth's (and other planets') magnetosphere, as well as possessing the modularity to integrate separate applications (apps) that can map to specific magnetosphere locations and/or perform the subsequent radiation transport and dosimetry for a specific target.

  10. Neodymium Isotopic Compositions of the Titanite Reference Materials Used in U-Pb Geochronology

    NASA Astrophysics Data System (ADS)

    Ma, Q.; Yang, Y.; Zhao, Z.

    2017-12-01

    Titanite (CaTiSiO5) is a widespread mineral and preferentially incorporates considerable uranium and significant light rare earth elements (LREEs) in its structure. Geochronology based upon U-Pb and Pb-Pb analyses of titanite has proven to be useful for understanding the P-T-t evolution of many igneous, metamorphic and hydrothermally altered rock samples (Scott and St-Onge, 1995). In the meantime, Sm-Nd isotopic composition in single titanite can be used to obtain initial Nd isotope composition at the time of titanite crystallization when combined with its U-Pb age, making titanite the most versatile mineral for dating metamorphism and tracing hydrothermal source (Amelin et al., 2009). The widely utilized in situ analyses by SIMS and LA-(MC)-ICP-MS have emphasized the significance for uniform and homogeneous reference materials for external correction (Liu et al., 2012, Sun et al., 2012, Yang et al., 2014). Here, we present U-Pb ages and Sm-Nd isotope analyses of twelve natural titanite crystals (12YQ82, T004, Ontario, BLR-1, OLT1, Khan, Qinghu, TLS-36, NW-IOA, C253, Pakistan and MKED1) acquired by Agilent 7500a Q-ICP-MS and Neptune MC-ICP-MS, respectively, combined a 193 nm ArF excimer laser ablation system. For U-Pb dating, elemental fractionation and instrumental drift were externally corrected using MKED1 titanite standard, showing results of U-Pb analyses all within error of those recommended values. With respect to Sm-Nd isotopes, we employed the interference-free 147Sm/149Sm to deduct 144Sm isobaric interference on 144Nd, and the fractionation between 147Sm and 144Nd was calibrated using BLR-1 titanite, which is proved homogenous in Sm-Nd isotopic system. The obtained Sm-Nd isotopic compositions for natural titanite samples are all consistent with those values determined by isotope dilution (ID) MC-ICP-MS, demonstrating the precision and accuracy currently available for in situ Sm-Nd analyses. Our results demonstrate that BLR-1, OLT1 and Ontario titanites are relatively uniform and homogeneous in Sm-Nd isotopic system and thus can serve as ideal reference materials for external calibration during in situ Sm-Nd analysis.

  11. Corrigendum to ;Dipole moment and solvatochromism of benzoic acid liquid crystals: Tuning the dipole moment and molecular orbital energies by substituted Au under external electric field; [J. Mol. Struct. 1137 (2017) 440-452

    NASA Astrophysics Data System (ADS)

    Sıdır, Yadigar Gülseven; Sıdır, İsa; Demiray, Ferhat

    2017-08-01

    The authors regret to inform that three references in the article titled ;Dipole moment and solvatochromism of benzoic acid liquid crystals: Tuning the dipole moment and molecular orbital energies by substituted Au under external electric field; are not given in the manuscript. This is purely an oversight mistake. The references are as shown in this correction. The authors would like to apologize for any inconvenience caused.

  12. Apparatus for controlling the firing of rectifiers in polyphase rectifying circuits

    DOEpatents

    Yarema, R.J.

    1979-09-18

    A polyphase rectifier is controlled with precision by a circuit that filters and shifts a reference signal associated with each phase and that starts a ramp signal at a zero crossing of the shifted reference signal. The difference between the ramp signal and an external trigger signal is used to generate a pulse that switches power rectifiers into conduction. The circuit reduces effects of variations that introduce subharmonics into a rectified signal and it can be used for constant or time-varying external trigger signals.

  13. LCA and emergy accounting of aquaculture systems: towards ecological intensification.

    PubMed

    Wilfart, Aurélie; Prudhomme, Jehane; Blancheton, Jean-Paul; Aubin, Joël

    2013-05-30

    An integrated approach is required to optimise fish farming systems by maximising output while minimising their negative environmental impacts. We developed a holistic approach to assess the environmental performances by combining two methods based on energetic and physical flow analysis. Life Cycle Assessment (LCA) is a normalised method that estimates resource use and potential impacts throughout a product's life cycle. Emergy Accounting (EA) refers the amount of energy directly or indirectly required by a product or a service. The combination of these two methods was used to evaluate the environmental impacts of three contrasting fish-farming systems: a farm producing salmon in a recirculating system (RSF), a semi-extensive polyculture pond (PF1) and an extensive polyculture pond (PF2). The RSF system, with a low feed-conversion ratio (FCR = 0.95), had lower environmental impacts per tonne of live fish produced than did the two pond farms, when the effects on climate change, acidification, total cumulative energy demand, land competition and water dependence were considered. However, RSF was clearly disconnected from the surrounding environment and depended highly on external resources (e.g. nutrients, energy). Ponds adequately incorporated renewable natural resources but had higher environmental impacts due to incomplete use of external inputs. This study highlighted key factors necessary for the successful ecological intensification of fish farming, i.e., minimise external inputs, lower the FCR, and increase the use of renewable resources from the surrounding environment. The combination of LCA and EA seems to be a practical approach to address the complexity of optimising biophysical efficiency in aquaculture systems. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. [Accidents by external causes in adolescents: care in sentinel urgency and emergency services in the Brazilian State Capitals--2009].

    PubMed

    Malta, Deborah Carvalho; Mascarenhas, Márcio Dênis Medeiros; Bernal, Regina Tomie Ivata; Andrade, Silvania Suely Caribé de Araújo; das Neves, Alice Cristina Medeiros; de Melo, Elza Machado; da Silva Junior, Jarbas Barbosa

    2012-09-01

    Adolescents are seeking new references and experiences, which may involve attitudes of risk and exposure to accidents and violence from external causes. These events constitute a serious Public Health problem. The scope of this study was to analyze the occurrence of accidents by external causes in adolescents from 10 to 19 years of age attended at sentinel urgency and emergency services in Brazil. Data from the 2009 Surveillance System for Violence and Accidents (VIVA 2009) was analyzed in 74 emergency units in 23 state capitals and the Federal District. The findings revealed that 6,434 adolescents (89.8%) were victims of accidents and 730 (10.2 %) were victims of violence. The main causes of the accidents were falls and traffic accidents, and assaults were predominant in violence. For both accidents and violence, non-white male adolescents were predominant and the events occurred most frequently on the public highways. A marked increase was detected, with hospitalization of victims of violence between 15 and 19 years of age. Understanding the epidemiological reality of external causes among adolescents represents an important tool for health prevention and promotion policies and the culture of peace seeking to reduce morbidity and mortality.

  15. Triggered dynamics in a model of different fault creep regimes

    PubMed Central

    Kostić, Srđan; Franović, Igor; Perc, Matjaž; Vasović, Nebojša; Todorović, Kristina

    2014-01-01

    The study is focused on the effect of transient external force induced by a passing seismic wave on fault motion in different creep regimes. Displacement along the fault is represented by the movement of a spring-block model, whereby the uniform and oscillatory motion correspond to the fault dynamics in post-seismic and inter-seismic creep regime, respectively. The effect of the external force is introduced as a change of block acceleration in the form of a sine wave scaled by an exponential pulse. Model dynamics is examined for variable parameters of the induced acceleration changes in reference to periodic oscillations of the unperturbed system above the supercritical Hopf bifurcation curve. The analysis indicates the occurrence of weak irregular oscillations if external force acts in the post-seismic creep regime. When fault motion is exposed to external force in the inter-seismic creep regime, one finds the transition to quasiperiodic- or chaos-like motion, which we attribute to the precursory creep regime and seismic motion, respectively. If the triggered acceleration changes are of longer duration, a reverse transition from inter-seismic to post-seismic creep regime is detected on a larger time scale. PMID:24954397

  16. IRIS Toxicological Review of 2,2',4,4'-Tetrabromodiphenyl ...

    EPA Pesticide Factsheets

    The U.S. EPA is conducting a peer review of the scientific basis supporting the human health hazard and dose-response assessments of congeners of polybrominated diphenyl ethers (PDBEs), this review is about 2,2',4,4'-Tetrabromodiphenyl Ether, or commonly referred to as tetraBDE (BDE-47). Following the external peer review this assessment will appear in the Integrated Risk Information System (IRIS) database. Peer review will ensure that science is used credibly and appropriately in derivation of the dose-response assessments and toxicological characterization. EPA is updating the Integrated Risk Information System (IRIS) health assessments for the PBDEs.

  17. Coordinated turn-and-reach movements. II. Planning in an external frame of reference

    NASA Technical Reports Server (NTRS)

    Pigeon, Pascale; Bortolami, Simone B.; DiZio, Paul; Lackner, James R.

    2003-01-01

    The preceding study demonstrated that normal subjects compensate for the additional interaction torques generated when a reaching movement is made during voluntary trunk rotation. The present paper assesses the influence of trunk rotation on finger trajectories and on interjoint coordination and determines whether simultaneous turn-and-reach movements are most simply described relative to a trunk-based or an external reference frame. Subjects reached to targets requiring different extents of arm joint and trunk rotation at a natural pace and quickly in normal lighting and in total darkness. We first examined whether the larger interaction torques generated during rapid turn-and-reach movements perturb finger trajectories and interjoint coordination and whether visual feedback plays a role in compensating for these torques. These issues were addressed using generalized Procrustes analysis (GPA), which attempts to overlap a group of configurations (e.g., joint trajectories) through translations and rotations in multi-dimensional space. We first used GPA to identify the mean intrinsic patterns of finger and joint trajectories (i.e., their average shape irrespective of location and orientation variability in the external and joint workspaces) from turn-and-reach movements performed in each experimental condition and then calculated their curvatures. We then quantified the discrepancy between each finger or joint trajectory and the intrinsic pattern both after GPA was applied individually to trajectories from a pair of experimental conditions and after GPA was applied to the same trajectories pooled together. For several subjects, joint trajectories but not finger trajectories were more curved in fast than slow movements. The curvature of both joint and finger trajectories of turn-and-reach movements was relatively unaffected by the vision conditions. Pooling across speed conditions significantly increased the discrepancy between joint but not finger trajectories for most subjects, indicating that subjects used different patterns of interjoint coordination in slow and fast movements while nevertheless preserving the shape of their finger trajectory. Higher movement speeds did not disrupt the arm joint rotations despite the larger interaction torques generated. Rather, subjects used the redundant degrees of freedom of the arm/trunk system to achieve similar finger trajectories with differing joint configurations. We examined finger movement patterns and velocity profiles to determine the frame of reference in which turn-and-reach movements could be most simply described. Finger trajectories of turn-and-reach movements had much larger curvatures and their velocity profiles were less smooth and less bell-like in trunk-based coordinates than in external coordinates. Taken together, these results support the conclusion that turn-and-reach movements are controlled in an external frame of reference.

  18. Comfort air temperature influence on heating and cooling loads of a residential building

    NASA Astrophysics Data System (ADS)

    Stanciu, C.; Șoriga, I.; Gheorghian, A. T.; Stanciu, D.

    2016-08-01

    The paper presents the thermal behavior and energy loads of a two-level residential building designed for a family of four, two adults and two students, for different inside comfort levels reflected by the interior air temperature. Results are intended to emphasize the different thermal behavior of building elements and their contribution to the building's external load. The most important contributors to the building thermal loss are determined. Daily heating and cooling loads are computed for 12 months simulation in Bucharest (44.25°N latitude) in clear sky conditions. The most important aspects regarding sizing of thermal energy systems are emphasized, such as the reference months for maximum cooling and heating loads and these loads’ values. Annual maximum loads are encountered in February and August, respectively, so these months should be taken as reference for sizing thermal building systems, in Bucharest, under clear sky conditions.

  19. Better-Than-Visual Technologies for Next Generation Air Transportation System Terminal Maneuvering Area Operations

    NASA Technical Reports Server (NTRS)

    Prinzel, Lawrence J., III; Bailey, Randall E.; Shelton, Kevin J.; Jones, Denise R.; Kramer, Lynda J.; Arthur, Jarvis J., III; Williams, Steve P.; Barmore, Bryan E.; Ellis, Kyle E.; Rehfeld, Sherri A.

    2011-01-01

    A consortium of industry, academia and government agencies are devising new concepts for future U.S. aviation operations under the Next Generation Air Transportation System (NextGen). Many key capabilities are being identified to enable NextGen, including the concept of Equivalent Visual Operations (EVO) replicating the capacity and safety of today's visual flight rules (VFR) in all-weather conditions. NASA is striving to develop the technologies and knowledge to enable EVO and to extend EVO towards a Better-Than-Visual (BTV) operational concept. The BTV operational concept uses an electronic means to provide sufficient visual references of the external world and other required flight references on flight deck displays that enable VFR-like operational tempos and maintain and improve the safety of VFR while using VFR-like procedures in all-weather conditions. NASA Langley Research Center (LaRC) research on technologies to enable the concept of BTV is described.

  20. Information on the Advanced Plant Experiment (APEX) Test Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, Curtis Lee

    The purpose of this report provides information related to the design of the Oregon State University Advanced Plant Experiment (APEX) test facility. Information provided in this report have been pulled from the following information sources: Reference 1: R. Nourgaliev and et.al, "Summary Report on NGSAC (Next-Generation Safety Analysis Code) Development and Testing," Idaho National Laboratory, 2011. Note that this is report has not been released as an external report. Reference 2: O. Stevens, Characterization of the Advanced Plant Experiment (APEX) Passive Residual Heat Removal System Heat Exchanger, Master Thesis, June 1996. Reference 3: J. Reyes, Jr., Q. Wu, and J.more » King, Jr., Scaling Assessment for the Design of the OSU APEX-1000 Test Facility, OSU-APEX-03001 (Rev. 0), May 2003. Reference 4: J. Reyes et al, Final Report of the NRC AP600 Research Conducted at Oregon State University, NUREG/CR-6641, July 1999. Reference 5: K. Welter et al, APEX-1000 Confirmatory Testing to Support AP1000 Design Certification (non-proprietary), NUREG-1826, August 2005.« less

  1. Development of a portable wireless system for bipolar concentric ECG recording

    NASA Astrophysics Data System (ADS)

    Prats-Boluda, G.; Ye-Lin, Y.; Bueno Barrachina, J. M.; Senent, E.; Rodriguez de Sanabria, R.; Garcia-Casado, J.

    2015-07-01

    Cardiovascular diseases (CVDs) remain the biggest cause of deaths worldwide. ECG monitoring is a key tool for early diagnosis of CVDs. Conventional monitors use monopolar electrodes resulting in poor spatial resolution surface recordings and requiring extensive wiring. High-spatial resolution surface electrocardiographic recordings provide valuable information for the diagnosis of a wide range of cardiac abnormalities, including infarction and arrhythmia. The aim of this work was to develop and test a wireless recording system for acquiring high spatial resolution ECG signals, based on a flexible tripolar concentric electrode (TCE) without cable wiring or external reference electrode which would make more comnfortable its use in clinical practice. For this, a portable, wireless sensor node for analogue conditioning, digitalization and transmission of a bipolar concentric ECG signal (BC-ECG) using a TCE and a Mason-likar Lead-I ECG (ML-Lead-I ECG) signal was developed. Experimental results from a total of 32 healthy volunteers showed that the ECG fiducial points in the BC-ECG signals, recorded with external and internal reference electrode, are consistent with those of simultaneous ML-Lead-I ECG. No statistically significant difference was found in either signal amplitude or morphology, regardless of the reference electrode used, being the signal-to-noise similar to that of ML-Lead-I ECG. Furthermore, it has been observed that BC-ECG signals contain information that could not available in conventional records, specially related to atria activity. The proposed wireless sensor node provides non-invasive high-local resolution ECG signals using only a TCE without additional wiring, which would have great potential in medical diagnosis of diseases such as atrial or ventricular fibrillations or arrhythmias that currently require invasive diagnostic procedures (catheterization).

  2. Effects of Performers' External Characteristics on Performance Evaluations.

    ERIC Educational Resources Information Center

    Bermingham, Gudrun A.

    2000-01-01

    States that fairness has been a major concern in the field of music adjudication. Reviews the research literature to reveal information about three external characteristics (race, gender, and physical attractiveness) that may affect judges' performance evaluations and influence fairness of music adjudication. Includes references. (CMK)

  3. A miniature Marine Aerosol Reference Tank (miniMART) as a compact breaking wave analogue

    NASA Astrophysics Data System (ADS)

    Stokes, M. Dale; Deane, Grant; Collins, Douglas B.; Cappa, Christopher; Bertram, Timothy; Dommer, Abigail; Schill, Steven; Forestieri, Sara; Survilo, Mathew

    2016-09-01

    In order to understand the processes governing the production of marine aerosols, repeatable, controlled methods for their generation are required. A new system, the miniature Marine Aerosol Reference Tank (miniMART), has been designed after the success of the original MART system, to approximate a small oceanic spilling breaker by producing an evolving bubble plume and surface foam patch. The smaller tank utilizes an intermittently plunging jet of water produced by a rotating water wheel, into an approximately 6 L reservoir to simulate bubble plume and foam formation and generate aerosols. This system produces bubble plumes characteristic of small whitecaps without the large external pump inherent in the original MART design. Without the pump it is possible to easily culture delicate planktonic and microbial communities in the bulk water during experiments while continuously producing aerosols for study. However, due to the reduced volume and smaller plunging jet, the absolute numbers of particles generated are approximately an order of magnitude less than in the original MART design.

  4. A novel high-resolution chaotic lidar with optical injection to chaotic laser diode

    NASA Astrophysics Data System (ADS)

    Wang, Yun-cai; Wang, An-bang

    2008-03-01

    A novel chaotic lidar with high resolution is proposed and studied theoretically. In chaotic lidar system, the chaotic laser emitted from chaotic laser diode is split into two beams: the probe and the reference light. The ranging is achieved by correlating the reference waveform with the delayed probe waveform backscattered from the target. In chaotic lidar systems presented previously, the chaotic signal source is laser diode with optical feedback or with optical injection by another one. The ranging resolution is limited by the bandwidth of chaotic laser which determined by the configuration of chaotic signal source. We proposed a novel chaotic lidar which ranging resolution is enhanced significantly by external optical injected chaotic laser diode. With the bandwidth-enhanced chaotic laser, the range resolution of the chaotic lidar system with optical injection is roughly two times compared with that of without optical injection. The resolution increases with injection strength increasing in a certain frequency detuning range.

  5. Mental states inside out: switching costs for emotional and nonemotional sentences that differ in internal and external focus.

    PubMed

    Oosterwijk, Suzanne; Winkielman, Piotr; Pecher, Diane; Zeelenberg, René; Rotteveel, Mark; Fischer, Agneta H

    2012-01-01

    Mental states-such as thinking, remembering, or feeling angry, happy, or dizzy-have a clear internal component. We feel a certain way when we are in these states. These internal experiences may be simulated when people understand conceptual references to mental states. However, mental states can also be described from an "external" perspective, for example when referring to "smiling." In those cases, simulation of visible outside features may be more relevant for understanding. In a switching costs paradigm, we presented semantically unrelated sentences describing emotional and nonemotional mental states while manipulating their internal or external focus. The results show that switching costs occur when participants shift between sentences with an internal and an external focus. This suggests that different forms of simulation underlie understanding these sentences. In addition, these effects occurred for emotional and nonemotional mental states, suggesting that they are grounded in a similar way-through the process of simulation.

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fromm, Andrea; Bonitz, Michael; Dufty, James

    The idea of treating quantum systems by semiclassical representations using effective quantum potentials (forces) has been successfully applied in equilibrium by many authors, see e.g. [D. Bohm, Phys. Rev. 85 (1986) 166 and 180; D.K. Ferry, J.R. Zhou, Phys. Rev. B 48 (1993) 7944; A.V. Filinov, M. Bonitz, W. Ebeling, J. Phys. A 36 (2003) 5957 and references cited therein]. Here, this idea is extended to nonequilibrium quantum systems in an external field. A gauge-invariant quantum kinetic theory for weakly inhomogeneous charged particle systems in a strong electromagnetic field is developed within the framework of nonequilibrium Green's functions. The equationmore » for the spectral density is simplified by introducing a classical (local) form for the kinetics. Nonlocal quantum effects are accounted for in this way by replacing the bare external confinement potential with an effective quantum potential. The equation for this effective potential is identified and solved for weak inhomogeneity in the collisionless limit. The resulting nonequilibrium spectral function is used to determine the density of states and the modification of the Born collision operator in the kinetic equation for the Wigner function due to quantum confinement effects.« less

  7. Applying Workspace Limitations in a Velocity-Controlled Robotic Mechanism

    NASA Technical Reports Server (NTRS)

    Abdallah, Muhammad E. (Inventor); Hargrave, Brian (Inventor); Platt, Robert J., Jr. (Inventor)

    2014-01-01

    A robotic system includes a robotic mechanism responsive to velocity control signals, and a permissible workspace defined by a convex-polygon boundary. A host machine determines a position of a reference point on the mechanism with respect to the boundary, and includes an algorithm for enforcing the boundary by automatically shaping the velocity control signals as a function of the position, thereby providing smooth and unperturbed operation of the mechanism along the edges and corners of the boundary. The algorithm is suited for application with higher speeds and/or external forces. A host machine includes an algorithm for enforcing the boundary by shaping the velocity control signals as a function of the reference point position, and a hardware module for executing the algorithm. A method for enforcing the convex-polygon boundary is also provided that shapes a velocity control signal via a host machine as a function of the reference point position.

  8. Reflections on Reference Services.

    ERIC Educational Resources Information Center

    Brandt, Kerryn A.; And Others

    1996-01-01

    Describes programmatic changes in reference services at the Johns Hopkins University (Maryland) medical library and speculates on the future. Topics include institutional restructuring and consolidation; improvements in technology infrastructure; external economic pressure; and fiscal accountability, including library funding and cost center…

  9. Introducing an Equal Rights Framework for Older Persons in Residential Care

    PubMed Central

    Jönson, Håkan; Harnett, Tove

    2016-01-01

    This article reconceptualizes residential care for older persons by introducing a framework developed from a rights-based principle of disability policies: the normalization principle. This principle is part of the social model and states that society should make available for people who have impairments living conditions that are as close as possible to those of “others.” Using the framework on the case of eldercare in Sweden shows that although disability policies have used people without impairments as a comparative (external) reference group for claiming rights, eldercare policies use internal reference groups, basing comparisons on other care users. The article highlights the need for external comparisons in eldercare and suggests that the third age, which so far has been a normative reference group for older people, could be a comparative reference group when older persons in need of care claim rights to equal conditions. PMID:26035884

  10. Thermal electron-tunneling devices as coolers and amplifiers

    NASA Astrophysics Data System (ADS)

    Su, Shanhe; Zhang, Yanchao; Chen, Jincan; Shih, Tien-Mo

    2016-02-01

    Nanoscale thermal systems that are associated with a pair of electron reservoirs have been previously studied. In particular, devices that adjust electron tunnels relatively to reservoirs’ chemical potentials enjoy the novelty and the potential. Since only two reservoirs and one tunnel exist, however, designers need external aids to complete a cycle, rendering their models non-spontaneous. Here we design thermal conversion devices that are operated among three electron reservoirs connected by energy-filtering tunnels and also referred to as thermal electron-tunneling devices. They are driven by one of electron reservoirs rather than the external power input, and are equivalent to those coupling systems consisting of forward and reverse Carnot cycles with energy selective electron functions. These previously-unreported electronic devices can be used as coolers and thermal amplifiers and may be called as thermal transistors. The electron and energy fluxes of devices are capable of being manipulated in the same or oppsite directions at our disposal. The proposed model can open a new field in the application of nano-devices.

  11. In-Flight Characterization of the Electromagnetic Environment Inside an Airliner

    NASA Technical Reports Server (NTRS)

    Moeller, Karl J.; Dudley, Kenneth L.; Quach, Cuong C.; Koppen, Sandra V.

    2001-01-01

    In 1995, the NASA Langley Research Center conducted a series of experimental measurements that characterized the electromagnetic environment (EME) inside a Boeing 757 airliner while in flight, Measurements were made of the electromagnetic energy coupled into a commercially configured aircraft as it was flown in close proximity to ground-based radio frequency (RF) transmitters operating at approximately 26, 173. and 430 MHz. The goal of this experiment was to collect data for the verification of analytical predictions of the internal aircraft response to an external stimulus. This paper describes the experiment, presents the data collected by it, and discusses techniques used to compute both the magnitude of the electric field illuminating the aircraft and its direction of propagation relative to a coordinate system fixed to the aircraft. The latter is determined from Global Positioning System (GPS) and aircraft Inertial Reference Unit (IRU) data. The paper concludes with an examination of the shielding effectiveness of the test aircraft. as determined by comparison of' the measured internal EME and computed external EME.

  12. Thermal electron-tunneling devices as coolers and amplifiers

    PubMed Central

    Su, Shanhe; Zhang, Yanchao; Chen, Jincan; Shih, Tien-Mo

    2016-01-01

    Nanoscale thermal systems that are associated with a pair of electron reservoirs have been previously studied. In particular, devices that adjust electron tunnels relatively to reservoirs’ chemical potentials enjoy the novelty and the potential. Since only two reservoirs and one tunnel exist, however, designers need external aids to complete a cycle, rendering their models non-spontaneous. Here we design thermal conversion devices that are operated among three electron reservoirs connected by energy-filtering tunnels and also referred to as thermal electron-tunneling devices. They are driven by one of electron reservoirs rather than the external power input, and are equivalent to those coupling systems consisting of forward and reverse Carnot cycles with energy selective electron functions. These previously-unreported electronic devices can be used as coolers and thermal amplifiers and may be called as thermal transistors. The electron and energy fluxes of devices are capable of being manipulated in the same or oppsite directions at our disposal. The proposed model can open a new field in the application of nano-devices. PMID:26893109

  13. The Search is on for Coherent Performance Measurement in Healthcare Organizations. Has Quebec Reached a Crossroads?

    PubMed

    Fache, Philippe; Sicotte, Claude; Minvielle, Étienne

    2016-05-01

    This research looks back at a 10-year period (2004-2014) to understand the development and outlook for healthcare organization performance measurement in the Quebec healthcare system, in an attempt to objectivize relationships within the configuration of its principal institutional actors. This is a qualitative study combining the use of official publications and fieldwork based on 13 semi-directed interviews, conducted in 2014, with informers in key performance measurement positions within the Quebec healthcare system. Performance measurement has generated tensions, both internally between different branches of the Department of Health and externally against a strong coalition of external institutional actors, which were defending a shared homogeneous vision of performance. Four major types of political power plays, owing to the power struggles around performance models and indicators, converged around the same implicit issue of the need to attain greater legitimacy in order to impose an authoritative frame of reference. Copyright © 2016 Longwoods Publishing.

  14. Adaptive fixed-time trajectory tracking control of a stratospheric airship.

    PubMed

    Zheng, Zewei; Feroskhan, Mir; Sun, Liang

    2018-05-01

    This paper addresses the fixed-time trajectory tracking control problem of a stratospheric airship. By extending the method of adding a power integrator to a novel adaptive fixed-time control method, the convergence of a stratospheric airship to its reference trajectory is guaranteed to be achieved within a fixed time. The control algorithm is firstly formulated without the consideration of external disturbances to establish the stability of the closed-loop system in fixed-time and demonstrate that the convergence time of the airship is essentially independent of its initial conditions. Subsequently, a smooth adaptive law is incorporated into the proposed fixed-time control framework to provide the system with robustness to external disturbances. Theoretical analyses demonstrate that under the adaptive fixed-time controller, the tracking errors will converge towards a residual set in fixed-time. The results of a comparative simulation study with other recent methods illustrate the remarkable performance and superiority of the proposed control method. Copyright © 2018 ISA. Published by Elsevier Ltd. All rights reserved.

  15. Hematological indices of injury to lightly oiled birds from the Deepwater Horizon oil spill

    USGS Publications Warehouse

    Fallon, Jesse A.; Smith, Eric P.; Schoch, Nina; Paruk, James D.; Adams, Evan A.; Evers, David C.; Jodice, Patrick G. R.; Perkins, Christopher; Schulte, Shiloh A.; Hopkins, William A.

    2018-01-01

    Avian mortality events are common following large‐scale oil spills. However, the sublethal effects of oil on birds exposed to light external oiling are not clearly understood. We found that American oystercatchers (area of potential impact n = 42, reference n = 21), black skimmers (area of potential impact n = 121, reference n = 88), brown pelicans (area of potential impact n = 91, reference n = 48), and great egrets (area of potential impact n = 57, reference n = 47) captured between 20 June 2010 and 23 February 2011 following the Deepwater Horizon oil spill experienced oxidative injury to erythrocytes, had decreased volume of circulating erythrocytes, and showed evidence of a regenerative hematological response in the form of increased reticulocytes compared with reference populations. Erythrocytic inclusions consistent with Heinz bodies were present almost exclusively in birds from sites impacted with oil, a finding pathognomonic for oxidative injury to erythrocytes. Average packed cell volumes were 4 to 19% lower and average reticulocyte counts were 27 to 40% higher in birds with visible external oil than birds from reference sites. These findings provide evidence that small amounts of external oil exposure are associated with hemolytic anemia. Furthermore, we found that some birds captured from the area impacted by the spill but with no visible oiling also had erythrocytic inclusion bodies, increased reticulocytes, and reduced packed cell volumes when compared with birds from reference sites. Thus, birds suffered hematologic injury despite no visible oil at the time of capture. Together, these findings suggest that adverse effects of oil spills on birds may be more widespread than estimates based on avian mortality or severe visible oiling.

  16. Self-reported emotional and behavioral symptoms, parent-adolescent bonding and family functioning in clinically referred adolescent offspring of Croatian PTSD war veterans.

    PubMed

    Boričević Maršanić, Vlatka; Aukst Margetić, Branka; Jukić, Vlado; Matko, Vlasta; Grgić, Vesna

    2014-05-01

    The presence of posttraumatic stress disorder (PTSD) in male war veterans has been linked with family dysfunction and psychopathology in their children [1, 2]. This study aimed to evaluate self-reported emotional and behavioral symptoms, parent-adolescent bonding and family functioning in clinically referred adolescent offspring of Croatian PTSD war veterans and determine the degree that parent-child bonding and family functioning contributed to adolescent behavior problems. Internalizing and externalizing behavior problems, parent-child bonding and family functioning were assessed in a sample of clinically referred Croatian PTSD veterans adolescent offspring (N = 122) and non-PTSD veteran adolescent offspring (N = 122) matched for age, sex, educational level, family income, parental employment status, ethnicity, and residential area. Youth Self-Report, Parental Bonding Instrument, Family Assessment Device were used. Adolescent offspring of PTSD veterans reported having significantly more internalizing and externalizing problems than non-PTSD veteran offspring, and also more difficulties in their family functioning, lower levels of maternal and paternal care, and more impaired mother-child and father-child bonding than control subjects. Internalizing symptoms were associated with family dysfunction, while externalizing symptoms were associated with paternal overcontrol/overprotection, and low maternal and paternal care. In conclusion, the increase in internalizing and externalizing symptoms as well as family and parental dysfunction among clinically referred adolescent offspring of PTSD veterans compared to their non-PTSD veteran counterparts indicates a need for early detection and interventions targeting both adolescent psychopathology and family relationships.

  17. Optically transmitted and inductively coupled electric reference to access in vivo concentrations for quantitative proton-decoupled ¹³C magnetic resonance spectroscopy.

    PubMed

    Chen, Xing; Pavan, Matteo; Heinzer-Schweizer, Susanne; Boesiger, Peter; Henning, Anke

    2012-01-01

    This report describes our efforts on quantification of tissue metabolite concentrations in mM by nuclear Overhauser enhanced and proton decoupled (13) C magnetic resonance spectroscopy and the Electric Reference To access In vivo Concentrations (ERETIC) method. Previous work showed that a calibrated synthetic magnetic resonance spectroscopy-like signal transmitted through an optical fiber and inductively coupled into a transmit/receive coil represents a reliable reference standard for in vivo (1) H magnetic resonance spectroscopy quantification on a clinical platform. In this work, we introduce a related implementation that enables simultaneous proton decoupling and ERETIC-based metabolite quantification and hence extends the applicability of the ERETIC method to nuclear Overhauser enhanced and proton decoupled in vivo (13) C magnetic resonance spectroscopy. In addition, ERETIC signal stability under the influence of simultaneous proton decoupling is investigated. The proposed quantification method was cross-validated against internal and external reference standards on human skeletal muscle. The ERETIC signal intensity stability was 100.65 ± 4.18% over 3 months including measurements with and without proton decoupling. Glycogen and unsaturated fatty acid concentrations measured with the ERETIC method were in excellent agreement with internal creatine and external phantom reference methods, showing a difference of 1.85 ± 1.21% for glycogen and 1.84 ± 1.00% for unsaturated fatty acid between ERETIC and creatine-based quantification, whereas the deviations between external reference and creatine-based quantification are 6.95 ± 9.52% and 3.19 ± 2.60%, respectively. Copyright © 2011 Wiley Periodicals, Inc.

  18. High resolution interrogation system for fiber Bragg grating (FBG) sensor application using radio frequency spectrum analyser

    NASA Astrophysics Data System (ADS)

    Muhammad, F. D.; Zulkifli, M. Z.; Harun, S. W.; Ahmad, H.

    2013-05-01

    In this paper, we propose a fiber Bragg grating (FBG) interrogation system for high resolution sensor application based on radio frequency (RF) generation technique by beating a single longitudinal mode (SLM) fiber ring laser with an external tunable laser source (TLS). The external TLS provides a constant wavelength (CW), functioning as the reference signal for the frequency beating technique. The TLS used has a constant output power and wavelength over time. The sensor signal is provided by the reflected wavelength of a typical fiber Bragg grating (FBG) in the SLM fiber ring laser, which consists of a 1 m long highly doped Erbium doped fiber as the gain medium. The key to ensure the SLM laser oscillation is the role of graphene as saturable absorber which is opposed to the commonly used unpumped erbiumdoped fiber and this consequently contributes to the simple and short cavity design of our proposed system. The signal from the SLM fiber ring laser, which is generated by the FBG in response to external changes, such as temperature, strain, air humidity and air movement, is heterodyned with the CW signal from the TLS at a 6 GHz photodetector using a 3-dB fused coupler to generate the frequency beating. This proposed system is experimentally demonstrated as a temperature sensor and the results shows that the frequency response of the system towards the changes in temperature is about 1.3 GHz/°C, taking into account the resolution bandwidth of 3 MHz of the radio frequency spectrum analyzer (RFSA).

  19. Neurodynamics in the Sensorimotor Loop: Representing Behavior Relevant External Situations

    PubMed Central

    Pasemann, Frank

    2017-01-01

    In the context of the dynamical system approach to cognition and supposing that brains or brain-like systems controlling the behavior of autonomous systems are permanently driven by their sensor signals, the paper approaches the question of neurodynamics in the sensorimotor loop in a purely formal way. This is carefully done by addressing the problem in three steps, using the time-discrete dynamics of standard neural networks and a fiber space representation for better clearness. Furthermore, concepts like meta-transients, parametric stability and dynamical forms are introduced, where meta-transients describe the effect of realistic sensor inputs, parametric stability refers to a class of sensor inputs all generating the “same type” of dynamic behavior, and a dynamical form comprises the corresponding class of parametrized dynamical systems. It is argued that dynamical forms are the essential internal representatives of behavior relevant external situations. Consequently, it is suggested that dynamical forms are the basis for a memory of these situations. Finally, based on the observation that not all brain process have a direct effect on the motor activity, a natural splitting of neurodynamics into vertical (internal) and horizontal (effective) parts is introduced. PMID:28217092

  20. Pulsar Timing and Its Application for Navigation and Gravitational Wave Detection

    NASA Astrophysics Data System (ADS)

    Becker, Werner; Kramer, Michael; Sesana, Alberto

    2018-02-01

    Pulsars are natural cosmic clocks. On long timescales they rival the precision of terrestrial atomic clocks. Using a technique called pulsar timing, the exact measurement of pulse arrival times allows a number of applications, ranging from testing theories of gravity to detecting gravitational waves. Also an external reference system suitable for autonomous space navigation can be defined by pulsars, using them as natural navigation beacons, not unlike the use of GPS satellites for navigation on Earth. By comparing pulse arrival times measured on-board a spacecraft with predicted pulse arrivals at a reference location (e.g. the solar system barycenter), the spacecraft position can be determined autonomously and with high accuracy everywhere in the solar system and beyond. We describe the unique properties of pulsars that suggest that such a navigation system will certainly have its application in future astronautics. We also describe the on-going experiments to use the clock-like nature of pulsars to "construct" a galactic-sized gravitational wave detector for low-frequency (f_{GW}˜ 10^{-9} - 10^{-7} Hz) gravitational waves. We present the current status and provide an outlook for the future.

  1. AIR QUALITY CRITERIA FOR PARTICULATE MATTER, VOLUMES I-III, (EXTERNAL REVIEW DRAFT, 1995)

    EPA Science Inventory

    There is no abstract available for these documents.

    If further information is requested, please refer to the bibliographic citation and contact the Technical Information Staff at the number listed above.

    • Air Quality Criteria for Particulate Matter, Volume I, Extern...

    • Repeatable reference for positioning sensors and transducers in drill pipe

      DOEpatents

      Hall, David R.; Fox, Joe; Pixton, David S.; Hall, Jr., H. Tracy

      2005-05-03

      A drill pipe having a box end having a tapered thread, and an internal shoulder and an external face for engagement with a drill pipe pin end having a tapered mating thread, and an external shoulder and an external face adapted for data acquisition or transmission. The relative dimensions of the box and pin ends are precisely controlled so that when the tool joint is made up, a repeatable reference plane is established for transmitting power and tuning downhole sensors, transducers, and means for sending and receiving data along the drill string. When the power or data acquisition and transmission means are located in the tool joint, the dimensions of the tool joint are further proportioned to compensate for the loss of cross-sectional area in order maintain the joints ability to sustain nominal makeup torque.

    • Effect of Extended State Observer and Automatic Voltage Regulator on Synchronous Machine Connected to Infinite Bus Power System

      NASA Astrophysics Data System (ADS)

      Angu, Rittu; Mehta, R. K.

      2018-04-01

      This paper presents a robust controller known as Extended State Observer (ESO) in order to improve the stability and voltage regulation of a synchronous machine connected to an infinite bus power system through a transmission line. The ESO-based control scheme is implemented with an automatic voltage regulator in conjunction with an excitation system to enhance the damping of low frequency power system oscillations, as the Power System Stabilizer (PSS) does. The implementation of PSS excitation control techniques however requires reliable information about the entire states, though they are not always directly measureable. To address this issue, the proposed ESO provides the estimate of system states as well as disturbance state together in order to improve not only the damping but also compensates system efficiently in presence of parameter uncertainties and external disturbances. The Closed-Loop Poles (CLPs) of the system have been assigned by the symmetric root locus technique, with the desired level of system damping provided by the dominant CLPs. The performance of the system is analyzed through simulating at different operating conditions. The control method is not only capable of providing zero estimation error in steady-state, but also shows robustness in tracking the reference command under parametric variations and external disturbances. Illustrative examples have been provided to demonstrate the effectiveness of the developed methodology.

    • First Definition of Reference Intervals of Liver Function Tests in China: A Large-Population-Based Multi-Center Study about Healthy Adults

      PubMed Central

      Zhang, Chuanbao; Guo, Wei; Huang, Hengjian; Ma, Yueyun; Zhuang, Junhua; Zhang, Jie

      2013-01-01

      Background Reference intervals of Liver function tests are very important for the screening, diagnosis, treatment, and monitoring of liver diseases. We aim to establish common reference intervals of liver function tests specifically for the Chinese adult population. Methods A total of 3210 individuals (20–79 years) were enrolled in six representative geographical regions in China. Analytes of ALT, AST, GGT, ALP, total protein, albumin and total bilirubin were measured using three analytical systems mainly used in China. The newly established reference intervals were based on the results of traceability or multiple systems, and then validated in 21 large hospitals located nationwide qualified by the National External Quality Assessment (EQA) of China. Results We had been established reference intervals of the seven liver function tests for the Chinese adult population and found there were apparent variances of reference values for the variables for partitioning analysis such as gender(ALT, GGT, total bilirubin), age(ALP, albumin) and region(total protein). More than 86% of the 21 laboratories passed the validation in all subgroup of reference intervals and overall about 95.3% to 98.8% of the 1220 validation results fell within the range of the new reference interval for all liver function tests. In comparison with the currently recommended reference intervals in China, the single side observed proportions of out of range of reference values from our study for most of the tests deviated significantly from the nominal 2.5% such as total bilirubin (15.2%), ALP (0.2%), albumin (0.0%). Most of reference intervals in our study were obviously different from that of other races. Conclusion These used reference intervals are no longer applicable for the current Chinese population. We have established common reference intervals of liver function tests that are defined specifically for Chinese population and can be universally used among EQA-approved laboratories located all over China. PMID:24058449

    • Anatomical Entity Recognition with a Hierarchical Framework Augmented by External Resources

      PubMed Central

      Xu, Yan; Hua, Ji; Ni, Zhaoheng; Chen, Qinlang; Fan, Yubo; Ananiadou, Sophia; Chang, Eric I-Chao; Tsujii, Junichi

      2014-01-01

      References to anatomical entities in medical records consist not only of explicit references to anatomical locations, but also other diverse types of expressions, such as specific diseases, clinical tests, clinical treatments, which constitute implicit references to anatomical entities. In order to identify these implicit anatomical entities, we propose a hierarchical framework, in which two layers of named entity recognizers (NERs) work in a cooperative manner. Each of the NERs is implemented using the Conditional Random Fields (CRF) model, which use a range of external resources to generate features. We constructed a dictionary of anatomical entity expressions by exploiting four existing resources, i.e., UMLS, MeSH, RadLex and BodyPart3D, and supplemented information from two external knowledge bases, i.e., Wikipedia and WordNet, to improve inference of anatomical entities from implicit expressions. Experiments conducted on 300 discharge summaries showed a micro-averaged performance of 0.8509 Precision, 0.7796 Recall and 0.8137 F1 for explicit anatomical entity recognition, and 0.8695 Precision, 0.6893 Recall and 0.7690 F1 for implicit anatomical entity recognition. The use of the hierarchical framework, which combines the recognition of named entities of various types (diseases, clinical tests, treatments) with information embedded in external knowledge bases, resulted in a 5.08% increment in F1. The resources constructed for this research will be made publicly available. PMID:25343498

    • Use of diagnostic accuracy as a metric for evaluating laboratory proficiency with microarray assays using mixed-tissue RNA reference samples.

      PubMed

      Pine, P S; Boedigheimer, M; Rosenzweig, B A; Turpaz, Y; He, Y D; Delenstarr, G; Ganter, B; Jarnagin, K; Jones, W D; Reid, L H; Thompson, K L

      2008-11-01

      Effective use of microarray technology in clinical and regulatory settings is contingent on the adoption of standard methods for assessing performance. The MicroArray Quality Control project evaluated the repeatability and comparability of microarray data on the major commercial platforms and laid the groundwork for the application of microarray technology to regulatory assessments. However, methods for assessing performance that are commonly applied to diagnostic assays used in laboratory medicine remain to be developed for microarray assays. A reference system for microarray performance evaluation and process improvement was developed that includes reference samples, metrics and reference datasets. The reference material is composed of two mixes of four different rat tissue RNAs that allow defined target ratios to be assayed using a set of tissue-selective analytes that are distributed along the dynamic range of measurement. The diagnostic accuracy of detected changes in expression ratios, measured as the area under the curve from receiver operating characteristic plots, provides a single commutable value for comparing assay specificity and sensitivity. The utility of this system for assessing overall performance was evaluated for relevant applications like multi-laboratory proficiency testing programs and single-laboratory process drift monitoring. The diagnostic accuracy of detection of a 1.5-fold change in signal level was found to be a sensitive metric for comparing overall performance. This test approaches the technical limit for reliable discrimination of differences between two samples using this technology. We describe a reference system that provides a mechanism for internal and external assessment of laboratory proficiency with microarray technology and is translatable to performance assessments on other whole-genome expression arrays used for basic and clinical research.

    • External quality assurance programs as a tool for verifying standardization of measurement procedures: Pilot collaboration in Europe.

      PubMed

      Perich, C; Ricós, C; Alvarez, V; Biosca, C; Boned, B; Cava, F; Doménech, M V; Fernández-Calle, P; Fernández-Fernández, P; García-Lario, J V; Minchinela, J; Simón, M; Jansen, R

      2014-05-15

      Current external quality assurance schemes have been classified into six categories, according to their ability to verify the degree of standardization of the participating measurement procedures. SKML (Netherlands) is a Category 1 EQA scheme (commutable EQA materials with values assigned by reference methods), whereas SEQC (Spain) is a Category 5 scheme (replicate analyses of non-commutable materials with no values assigned by reference methods). The results obtained by a group of Spanish laboratories participating in a pilot study organized by SKML are examined, with the aim of pointing out the improvements over our current scheme that a Category 1 program could provide. Imprecision and bias are calculated for each analyte and laboratory, and compared with quality specifications derived from biological variation. Of the 26 analytes studied, 9 had results comparable with those from reference methods, and 10 analytes did not have comparable results. The remaining 7 analytes measured did not have available reference method values, and in these cases, comparison with the peer group showed comparable results. The reasons for disagreement in the second group can be summarized as: use of non-standard methods (IFCC without exogenous pyridoxal phosphate for AST and ALT, Jaffé kinetic at low-normal creatinine concentrations and with eGFR); non-commutability of the reference material used to assign values to the routine calibrator (calcium, magnesium and sodium); use of reference materials without established commutability instead of reference methods for AST and GGT, and lack of a systematic effort by manufacturers to harmonize results. Results obtained in this work demonstrate the important role of external quality assurance programs using commutable materials with values assigned by reference methods to correctly monitor the standardization of laboratory tests with consequent minimization of risk to patients. Copyright © 2013 Elsevier B.V. All rights reserved.

    • Computation of high Reynolds number internal/external flows

      NASA Technical Reports Server (NTRS)

      Cline, M. C.; Wilmoth, R. G.

      1981-01-01

      A general, user oriented computer program, called VNAP2, was developed to calculate high Reynolds number, internal/ external flows. The VNAP2 program solves the two dimensional, time dependent Navier-Stokes equations. The turbulence is modeled with either a mixing-length, a one transport equation, or a two transport equation model. Interior grid points are computed using the explicit MacCormack Scheme with special procedures to speed up the calculation in the fine grid. All boundary conditions are calculated using a reference plane characteristic scheme with the viscous terms treated as source terms. Several internal, external, and internal/external flow calculations are presented.

    • Computation of high Reynolds number internal/external flows

      NASA Technical Reports Server (NTRS)

      Cline, M. C.; Wilmoth, R. G.

      1981-01-01

      A general, user oriented computer program, called VNAF2, developed to calculate high Reynolds number internal/external flows is described. The program solves the two dimensional, time dependent Navier-Stokes equations. Turbulence is modeled with either a mixing length, a one transport equation, or a two transport equation model. Interior grid points are computed using the explicit MacCormack scheme with special procedures to speed up the calculation in the fine grid. All boundary conditions are calculated using a reference plane characteristic scheme with the viscous terms treated as source terms. Several internal, external, and internal/external flow calculations are presented.

    • Centering a DDR Strobe in the Middle of a Data Packet

      NASA Technical Reports Server (NTRS)

      Johnson, Michael; Nelson, Dave; Seefeldt, James; Roper, Weston; Passow, Craig

      2014-01-01

      The Orion CEV Northstar ASIC (application- specific integrated circuit) project required a DDR (double data rate) memory bus driver/receiver (DDR PHY block) to interface with external DDR memory. The DDR interface (JESD79C) is based on a source synchronous strobe (DQS\\) that is sent along with each packet of data (DQ). New data is provided concurrently with each edge of strobe and is sent irregularly. In order to capture this data, the strobe needs to be delayed and used to latch the data into a register. A circuit solves the need for training a DDR PRY block by incorporating a PVT-compensated delay element in the strobe path. This circuit takes an external reference clock signal and uses the regular clock to calibrate a known delay through a data path. The compensated delay DQS signal is then used to capture the DQ data in a normal register. This register structure can be configured as a FIFO (first in first out), in order to transfer data from the DDR domain to the system clock domain. This design is different in that it does not rely upon the need for training the system response, nor does it use a PLL (phase locked loop) or a DLL (delay locked loop) to provide an offset of the strobe signal. The circuit is created using standard ASIC building blocks, plus the PVT (process, voltage, and temperature) compensated delay line. The design uses a globally available system clock as a reference, alleviating the need to operate synchronously with the remote memory. The reference clock conditions the PVT compensated delay line to provide a pre-determined amount of delay to any data signal that passes through this delay line. The delay line is programmed in degrees of offset, so that one could think of the clock period representing 360deg of delay. In an ideal environment, delaying the strobe 1/4 of a clock cycle (90deg) would place the strobe in the middle of the data packet. This delayed strobe can then be used to clock the data into a register, satisfying setup and hold requirements of the system.

    • Time of flight system on a chip

      NASA Technical Reports Server (NTRS)

      Paschalidis, Nicholas P. (Inventor)

      2006-01-01

      A CMOS time-of-flight TOF system-on-a-chip SoC for precise time interval measurement with low power consumption and high counting rate has been developed. The analog and digital TOF chip may include two Constant Fraction Discriminators CFDs and a Time-to-Digital Converter TDC. The CFDs can interface to start and stop anodes through two preamplifiers and perform signal processing for time walk compensation (110). The TDC digitizes the time difference with reference to an off-chip precise external clock (114). One TOF output is an 11-bit digital word and a valid event trigger output indicating a valid event on the 11-bit output bus (116).

    • Analysis of the Influence of Construction Insulation Systems on Public Safety in China

      PubMed Central

      Zhang, Guowei; Zhu, Guoqing; Zhao, Guoxiang

      2016-01-01

      With the Government of China’s proposed Energy Efficiency Regulations (GB40411-2007), the implementation of external insulation systems will be mandatory in China. The frequent external insulation system fires cause huge numbers of casualties and extensive property damage and have rapidly become a new hot issue in construction evacuation safety in China. This study attempts to reconstruct an actual fire scene and propose a quantitative risk assessment method for upward insulation system fires using thermal analysis tests and large eddy simulations (using the Fire Dynamics Simulator (FDS) software). Firstly, the pyrolysis and combustion characteristics of Extruded polystyrene board (XPS panel), such as ignition temperature, combustion heat, limiting oxygen index, thermogravimetric analysis and thermal radiation analysis were studied experimentally. Based on these experimental data, large eddy simulation was then applied to reconstruct insulation system fires. The results show that upward insulation system fires could be accurately reconstructed by using thermal analysis test and large eddy simulation. The spread of insulation material system fires in the vertical direction is faster than that in the horizontal direction. Moreover, we also find that there is a possibility of flashover in enclosures caused by insulation system fires as the smoke temperature exceeds 600 °C. The simulation methods and experimental results obtained in this paper could provide valuable references for fire evacuation, hazard assessment and fire resistant construction design studies. PMID:27589774

    • Analysis of the Influence of Construction Insulation Systems on Public Safety in China.

      PubMed

      Zhang, Guowei; Zhu, Guoqing; Zhao, Guoxiang

      2016-08-30

      With the Government of China's proposed Energy Efficiency Regulations (GB40411-2007), the implementation of external insulation systems will be mandatory in China. The frequent external insulation system fires cause huge numbers of casualties and extensive property damage and have rapidly become a new hot issue in construction evacuation safety in China. This study attempts to reconstruct an actual fire scene and propose a quantitative risk assessment method for upward insulation system fires using thermal analysis tests and large eddy simulations (using the Fire Dynamics Simulator (FDS) software). Firstly, the pyrolysis and combustion characteristics of Extruded polystyrene board (XPS panel), such as ignition temperature, combustion heat, limiting oxygen index, thermogravimetric analysis and thermal radiation analysis were studied experimentally. Based on these experimental data, large eddy simulation was then applied to reconstruct insulation system fires. The results show that upward insulation system fires could be accurately reconstructed by using thermal analysis test and large eddy simulation. The spread of insulation material system fires in the vertical direction is faster than that in the horizontal direction. Moreover, we also find that there is a possibility of flashover in enclosures caused by insulation system fires as the smoke temperature exceeds 600 °C. The simulation methods and experimental results obtained in this paper could provide valuable references for fire evacuation, hazard assessment and fire resistant construction design studies.

    • Integration of Hand and Finger Location in External Spatial Coordinates for Tactile Localization

      ERIC Educational Resources Information Center

      Heed, Tobias; Backhaus, Jenny; Roder, Brigitte

      2012-01-01

      Tactile stimulus location is automatically transformed from somatotopic into external spatial coordinates, rendering information about the location of touch in three-dimensional space. This process is referred to as tactile remapping. Whereas remapping seems to occur automatically for the hands and feet, the fingers may constitute an exception in…

    • The Internet as an External Economy: The Emergence of the Invisible Hand.

      ERIC Educational Resources Information Center

      Brownrigg, Edwin B.

      1991-01-01

      Discusses the Internet, an interconnected array of scientific research networks. The role of libraries in the Internet is discussed; the Coalition for Networked Information (CNI) and Advanced Network Services (ANS) are described; and economic issues of the Internet are raised, including external economy and public good. (eight references) (LRW)

    • 20 plus Years of Computational Fluid Dynamics for the Space Shuttle

      NASA Technical Reports Server (NTRS)

      Gomez, Reynaldo J., III

      2011-01-01

      This slide presentation reviews the use of computational fluid dynamics in performing analysis of the space shuttle with particular reference to the return to flight analysis and other shuttle problems. Slides show a comparison of pressure coefficient with the shuttle ascent configuration between the wind tunnel test and the computed values. the evolution of the grid system for the space shuttle launch vehicle (SSLv) from the early 80's to one in 2004, the grid configuration of the bipod ramp redesign from the original design to the current configuration, charts with the computations showing solid rocket booster surface pressures from wind tunnel data, calculated over two grid systems (i.e., the original 14 grid system, and the enhanced 113 grid system), and the computed flight orbiter wing loads are compared with strain gage data on STS-50 during flight. The loss of STS-107 initiated an unprecedented review of all external environments. The current SSLV grid system of 600+ grids, 1.8 Million surface points and 95+ million volume points is shown. The inflight entry analyses is shown, and the use of Overset CFD as a key part to many external tank redesign and debris assessments is discussed. The work that still remains to be accomplished for future shuttle flights is discussed.

    • Pneumatic oscillator circuits for timing and control of integrated microfluidics.

      PubMed

      Duncan, Philip N; Nguyen, Transon V; Hui, Elliot E

      2013-11-05

      Frequency references are fundamental to most digital systems, providing the basis for process synchronization, timing of outputs, and waveform synthesis. Recently, there has been growing interest in digital logic systems that are constructed out of microfluidics rather than electronics, as a possible means toward fully integrated laboratory-on-a-chip systems that do not require any external control apparatus. However, the full realization of this goal has not been possible due to the lack of on-chip frequency references, thus requiring timing signals to be provided from off-chip. Although microfluidic oscillators have been demonstrated, there have been no reported efforts to characterize, model, or optimize timing accuracy, which is the fundamental metric of a clock. Here, we report pneumatic ring oscillator circuits built from microfluidic valves and channels. Further, we present a compressible-flow analysis that differs fundamentally from conventional circuit theory, and we show the utility of this physically based model for the optimization of oscillator stability. Finally, we leverage microfluidic clocks to demonstrate circuits for the generation of phase-shifted waveforms, self-driving peristaltic pumps, and frequency division. Thus, pneumatic oscillators can serve as on-chip frequency references for microfluidic digital logic circuits. On-chip clocks and pumps both constitute critical building blocks on the path toward achieving autonomous laboratory-on-a-chip devices.

    • Make or Buy? That's Really Not the Question

      ERIC Educational Resources Information Center

      Peurach, Donald J.; Glazer, Joshua L.; Lenhoff, Sarah Winchell

      2012-01-01

      Conventional thinking holds that districts and schools face a strategic decision between two fundamentally different alternatives: make or buy? The former refers to planning, designing, and enacting school-specific improvement initiatives. The latter refers to contracting with external providers of schoolwide improvement programs. However, there…

    • Design and realization of 144 x 7 TDI ROIC with hybrid integrated test structure

      NASA Astrophysics Data System (ADS)

      Ceylan, Omer; Kayahan, Huseyin; Yazici, Melik; Baran, Muhammet Burak; Gurbuz, Yasar

      2012-06-01

      Design and realization of a 144x7 silicon readout integrated circuit (ROIC) based on switched capacitor TDI for MCT LWIR scanning type focal plane arrays (FPAs) and its corresponding hybrid integrated test circuits are presented. TDI operation with 7 detectors improves the SNR of the system by a factor of √7, while oversampling rate of 3 improves the spatial resolution of the system. ROIC supports bidirectional scan, 5 adjustable gain settings, bypass operation, automatic gain adjustment in case of mulfunctioning pixels and pixel select/deselect properties. Integration time of the system can be determined by the help of an external clock. Programming of ROIC can be done in parallel or serial mode according to the needs of the system. All properties except pixel select/deselect property can be performed in parallel mode, while pixel select/deselect property can be performed only in serial mode. ROIC can handle up to 3.75V dynamic range with a load of 25pF and output settling time of 80ns. Input referred noise of the ROIC is less than 750 rms electrons, while the power consumption is less than 100mW. To test ROIC in absence of detector array, a process and temperature compensated current reference array, which supplies uniform input current in range of 1-50nA to ROIC, is designed and measured both in room and cryogenic (77ºK) temperatures. Standard deviations of current reference arrays are measured 3.26% for 1nA and 0.99% for 50nA. ROIC and current reference array are fabricated seperately, and then flip-chip bonded for the test of the system. Flip-chip bonded system including ROIC and current reference test array is successfully measured both in room and cryogenic temperatures, and measurement results are presented. The manufacturing technology is 0.35μm, double poly-Si, four metal, 5V CMOS process.

    • Predictors of Parental Locus of Control in Mothers of Pre- and Early-Adolescents

      PubMed Central

      Freed, Rachel D.; Tompson, Martha C.

      2016-01-01

      Parental locus of control refers to parents’ perceived power and efficacy in child-rearing situations. This study explored parental locus of control and its correlates in 160 mothers of children ages 8–14 cross-sectionally and 1 year later. Maternal depression, maternal expressed emotion, and child internalizing and externalizing behavior were examined, along with a number of sociodemographic factors. Cross-sectional analyses indicated that external parental locus of control was associated with child externalizing behavior, maternal depression, less maternal education, lower income, and older maternal age. Longitudinal analyses showed that child age and externalizing behavior also predicted increases in external parental locus of control 1 year later. Finally, lower income and less parental perceived control predicted increases in child externalizing behavior over time. PMID:21229447

  1. Spike-In Normalization of ChIP Data Using DNA-DIG-Antibody Complex.

    PubMed

    Eberle, Andrea B

    2018-01-01

    Chromatin immunoprecipitation (ChIP) is a widely used method to determine the occupancy of specific proteins within the genome, helping to unravel the function and activity of specific genomic regions. In ChIP experiments, normalization of the obtained data by a suitable internal reference is crucial. However, particularly when comparing differently treated samples, such a reference is difficult to identify. Here, a simple method to improve the accuracy and reliability of ChIP experiments by the help of an external reference is described. An artificial molecule, composed of a well-defined digoxigenin (DIG) labeled DNA fragment in complex with an anti-DIG antibody, is synthesized and added to each chromatin sample before immunoprecipitation. During the ChIP procedure, the DNA-DIG-antibody complex undergoes the same treatments as the chromatin and is therefore purified and quantified together with the chromatin of interest. This external reference compensates for variability during the ChIP routine and improves the similarity between replicates, thereby emphasizing the biological differences between samples.

  2. The Effectiveness of Parent Management Training-Oregon Model in Clinically Referred Children with Externalizing Behavior Problems in The Netherlands.

    PubMed

    Thijssen, Jill; Vink, Gerko; Muris, Peter; de Ruiter, Corine

    2017-02-01

    The present study examined the effectiveness of parent management training-Oregon model (PMTO) as a treatment for children with externalizing behavior problems in The Netherlands. Clinically referred children (N = 146) aged 4-11 years and their parents were partly randomized to either PMTO (n = 91) or Care As Usual (CAU; n = 55). Families were assessed at four time points: at pretreatment, and after 6, 12, and 18 months. Results showed that both PMTO and CAU were effective in reducing child externalizing behavior, parenting stress and parental psychopathology, with no significant differences between the two treatment conditions. PMTO and CAU interventions also produced some improvements in self-reported parenting skills, but not in observed parenting skills. According to the Reliable Change Index, 16.9 and 45.8 % of the children within the PMTO group showed full recovery or improvement in externalizing behavior, respectively, versus 9.7 and 42.8 % in the CAU condition. Finally, the effect size of PMTO on parent-reported externalizing behavior problems as found in the present study was comparable to that found in previous studies evaluating PMTO as an intervention for this type of child psychopathology.

  3. Proxies and Other External Raters: Methodological Considerations

    PubMed Central

    Snow, A Lynn; Cook, Karon F; Lin, Pay-Shin; Morgan, Robert O; Magaziner, Jay

    2005-01-01

    Objective The purpose of this paper is to introduce researchers to the measurement and subsequent analysis considerations involved when using externally rated data. We will define and describe two categories of externally rated data, recommend methodological approaches for analyzing and interpreting data in these two categories, and explore factors affecting agreement between self-rated and externally rated reports. We conclude with a discussion of needs for future research. Data Sources/Study Setting Data sources for this paper are previous published studies and reviews comparing self-rated with externally rated data. Study Design/Data Collection/Extraction Methods This is a psychometric conceptual paper. Principal Findings We define two types of externally rated data: proxy data and other-rated data. Proxy data refer to those collected from someone who speaks for a patient who cannot, will not, or is unavailable to speak for him or herself, whereas we use the term other-rater data to refer to situations in which the researcher collects ratings from a person other than the patient to gain multiple perspectives on the assessed construct. These two types of data differ in the way the measurement model is defined, the definition of the gold standard against which the measurements are validated, the analysis strategies appropriately used, and how the analyses are interpreted. There are many factors affecting the discrepancies between self- and external ratings, including characteristics of the patient, the proxy, and of the rated construct. Several psychological theories can be helpful in predicting such discrepancies. Conclusions Externally rated data have an important place in health services research, but use of such data requires careful consideration of the nature of the data and how it will be analyzed and interpreted. PMID:16179002

  4. A New Socio-technical Model for Studying Health Information Technology in Complex Adaptive Healthcare Systems

    PubMed Central

    Sittig, Dean F.; Singh, Hardeep

    2011-01-01

    Conceptual models have been developed to address challenges inherent in studying health information technology (HIT). This manuscript introduces an 8-dimensional model specifically designed to address the socio-technical challenges involved in design, development, implementation, use, and evaluation of HIT within complex adaptive healthcare systems. The 8 dimensions are not independent, sequential, or hierarchical, but rather are interdependent and interrelated concepts similar to compositions of other complex adaptive systems. Hardware and software computing infrastructure refers to equipment and software used to power, support, and operate clinical applications and devices. Clinical content refers to textual or numeric data and images that constitute the “language” of clinical applications. The human computer interface includes all aspects of the computer that users can see, touch, or hear as they interact with it. People refers to everyone who interacts in some way with the system, from developer to end-user, including potential patient-users. Workflow and communication are the processes or steps involved in assuring that patient care tasks are carried out effectively. Two additional dimensions of the model are internal organizational features (e.g., policies, procedures, and culture) and external rules and regulations, both of which may facilitate or constrain many aspects of the preceding dimensions. The final dimension is measurement and monitoring, which refers to the process of measuring and evaluating both intended and unintended consequences of HIT implementation and use. We illustrate how our model has been successfully applied in real-world complex adaptive settings to understand and improve HIT applications at various stages of development and implementation. PMID:20959322

  5. A new sociotechnical model for studying health information technology in complex adaptive healthcare systems.

    PubMed

    Sittig, Dean F; Singh, Hardeep

    2010-10-01

    Conceptual models have been developed to address challenges inherent in studying health information technology (HIT). This manuscript introduces an eight-dimensional model specifically designed to address the sociotechnical challenges involved in design, development, implementation, use and evaluation of HIT within complex adaptive healthcare systems. The eight dimensions are not independent, sequential or hierarchical, but rather are interdependent and inter-related concepts similar to compositions of other complex adaptive systems. Hardware and software computing infrastructure refers to equipment and software used to power, support and operate clinical applications and devices. Clinical content refers to textual or numeric data and images that constitute the 'language' of clinical applications. The human--computer interface includes all aspects of the computer that users can see, touch or hear as they interact with it. People refers to everyone who interacts in some way with the system, from developer to end user, including potential patient-users. Workflow and communication are the processes or steps involved in ensuring that patient care tasks are carried out effectively. Two additional dimensions of the model are internal organisational features (eg, policies, procedures and culture) and external rules and regulations, both of which may facilitate or constrain many aspects of the preceding dimensions. The final dimension is measurement and monitoring, which refers to the process of measuring and evaluating both intended and unintended consequences of HIT implementation and use. We illustrate how our model has been successfully applied in real-world complex adaptive settings to understand and improve HIT applications at various stages of development and implementation.

  6. Focus control system for stretched-membrane mirror module

    DOEpatents

    Butler, B.L.; Beninga, K.J.

    1991-05-21

    A focus control system dynamically sets and controls the focal length of a reflective membrane supported between a perimeter frame. A rear membrane is also supported between the perimeter frame rearward and spaced apart from a back side of the reflective membrane. The space between the membranes defines a plenum space into which a mass of gas at a first pressure is inserted. The pressure differential between the first pressure and an external pressure, such as the atmospheric pressure, causes the reflective membrane to assume a first curvature relative to a reference plane associated with the perimeter frame. This curvature defines the focal length of the reflective membrane. The focal length is dynamically controlled by changing the volume of the plenum space, thereby changing the first pressure. The system can be used to change or maintain the pressure differential and hence the front membrane curvature. The plenum volume is changed by pushing or pulling on a central section of the rear membrane using a suitable actuator. Sensing means continuously sense the location of the reflective membrane relative to the reference plane. This sensed position is compared to a reference position, and a resulting error signal, comprising the difference between the sensed position and reference position, drives the actuator in a direction to minimize the difference. A vent value compensates for temperature changes or leaks in the closed volume by allowing the pressure differential to be adjusted as required to center the working range of the actuator about the desired focal length. 13 figures.

  7. Focus control system for stretched-membrane mirror module

    DOEpatents

    Butler, Barry L.; Beninga, Kelly J.

    1991-01-01

    A focus control system dynamically sets and controls the focal length of a reflective membrane supported between a perimeter frame. A rear membrane is also supported between the perimeter frame rearward and spaced apart from a back side of the reflective membrane. The space between the membranes defines a plenum space into which a mass of gas at a first pressure is inserted. The pressure differential between the first pressure and an external pressure, such as the atmospheric pressure, causes the reflective membrane to assume a first curvature relative to a reference plane associated with the perimeter frame. This curvature defines the focal length of the reflective membrane. The focal length is dynamically controlled by changing the volume of the plenum space, thereby changing the first pressure. The system can be used to change or maintain the pressure differential and hence the front membrane curvature. The plenum volume is changed by pushing or pulling on a central section of the rear membrane using a suitable actuator. Sensing means continuously sense the location of the reflective membrane relative to the reference plane. This sensed position is compared to a reference position, and a resulting error signal, comprising the difference between the sensed position and reference position, drives the actuator in a direction to minimize the difference. A vent value compensates for temperature changes or leaks in the closed volume by allowing the pressure differential to be adjusted as required to center the working range of the actuator about the desired focal length.

  8. Application of Semi Active Control Techniques to the Damping Suppression Problem of Solar Sail Booms

    NASA Technical Reports Server (NTRS)

    Adetona, O.; Keel, L. H.; Whorton, M. S.

    2007-01-01

    Solar sails provide a propellant free form for space propulsion. These are large flat surfaces that generate thrust when they are impacted by light. When attached to a space vehicle, the thrust generated can propel the space vehicle to great distances at significant speeds. For optimal performance the sail must be kept from excessive vibration. Active control techniques can provide the best performance. However, they require an external power-source that may create significant parasitic mass to the solar sail. However, solar sails require low mass for optimal performance. Secondly, active control techniques typically require a good system model to ensure stability and performance. However, the accuracy of solar sail models validated on earth for a space environment is questionable. An alternative approach is passive vibration techniques. These do not require an external power supply, and do not destabilize the system. A third alternative is referred to as semi-active control. This approach tries to get the best of both active and passive control, while avoiding their pitfalls. In semi-active control, an active control law is designed for the system, and passive control techniques are used to implement it. As a result, no external power supply is needed so the system is not destabilize-able. Though it typically underperforms active control techniques, it has been shown to out-perform passive control approaches and can be unobtrusively installed on a solar sail boom. Motivated by this, the objective of this research is to study the suitability of a Piezoelectric (PZT) patch actuator/sensor based semi-active control system for the vibration suppression problem of solar sail booms. Accordingly, we develop a suitable mathematical and computer model for such studies and demonstrate the capabilities of the proposed approach with computer simulations.

  9. Energy performance indicators of wastewater treatment: a field study with 17 Portuguese plants.

    PubMed

    Silva, Catarina; Rosa, Maria João

    2015-01-01

    The energy costs usually represent the second largest part of the running costs of a wastewater treatment plant (WWTP). It is therefore crucial to increase the energy efficiency of these infrastructures and to implement energy management systems, where quantitative performance metrics, such as performance indicators (PIs), play a key role. This paper presents energy PIs which cover the unit energy consumption, production, net use from external sources and costs, and the results used to validate them and derive their reference values. The results of a field study with 17 Portuguese WWTPs (5-year period) were consistent with the results obtained through an international literature survey on the two key parcels of the energy balance--consumption and production. The unit energy consumption showed an overall inverse relation with the volume treated, and the reference values reflect this relation for trickling filters and for activated sludge systems (conventional, with coagulation/filtration (C/F) and with nitrification and C/F). The reference values of electrical energy production were derived from the methane generation potential (converted to electrical energy) and literature data, whereas those of energy net use were obtained by the difference between the energy consumption and production.

  10. Postural compensation for vestibular loss and implications for rehabilitation.

    PubMed

    Horak, Fay B

    2010-01-01

    This chapter summarizes the role of the vestibular system in postural control so that specific and effective rehabilitation can be designed that facilitates compensation for loss of vestibular function. Patients with bilateral or unilateral loss of peripheral vestibular function are exposed to surface perturbations to quantify automatic postural responses. Studies also evaluated the effects of audio- and vibrotactile-biofeedback to improve stability in stance and gait. The most important role of vestibular information for postural control is to control orientation of the head and trunk in space with respect to gravitoinertial forces, particularly when balancing on unstable surfaces. Vestibular sensory references are particularly important for postural control at high frequencies and velocities of self-motion, to reduce trunk drift and variability, to provide an external reference frame for the trunk and head in space; and to uncouple coordination of the trunk from the legs and the head-in-space from the body CoM. The goal of balance rehabilitation for patients with vestibular loss is to help patients 1) use remaining vestibular function, 2) depend upon surface somatosensory information as their primary postural sensory system, 3) learn to use stable visual references, and 4) identify efficient and effective postural movement strategies.

  11. IRIS Toxicological Review of Vanadium Pentoxide (External Review Draft)

    EPA Science Inventory

    This vanadium pentoxide reassessment consists of an oral reference dose (RfD), an inhalation reference concentration (RfC), an inhalation unit risk (IUR) and a cancer weight of evidence descriptor. This is the first assessment developing an RfC or IUR for this compound. This as...

  12. Examining Associations between Narcissism, Behavior Problems, and Anxiety in Non-Referred Adolescents

    ERIC Educational Resources Information Center

    Lau, Katherine S. L.; Marsee, Monica A.; Kunimatsu, Melissa M.; Fassnacht, Gregory M.

    2011-01-01

    The present study examined associations between narcissism (total, adaptive, and maladaptive), self-esteem, and externalizing and internalizing problems in 157 non-referred adolescents (aged 14 to 18). Consistent with previous research, narcissism was positively associated with self-reported delinquency, overt aggression, and relational…

  13. Technical basis for external dosimetry at the Waste Isolation Pilot Plant (WIPP)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bradley, E.W.; Wu, C.F.; Goff, T.E.

    1993-12-31

    The WIPP External Dosimetry Program, administered by Westinghouse Electric Corporation, Waste Isolation Division, for the US Department of Energy (DOE), provides external dosimetry support services for operations at the Waste Isolation Pilot Plant (WIPP) Site. These operations include the receipt, experimentation with, storage, and disposal of transuranic (TRU) wastes. This document describes the technical basis for the WIPP External Radiation Dosimetry Program. The purposes of this document are to: (1) provide assurance that the WIPP External Radiation Dosimetry Program is in compliance with all regulatory requirements, (2) provide assurance that the WIPP External Radiation Dosimetry Program is derived from amore » sound technical base, (3) serve as a technical reference for radiation protection personnel, and (4) aid in identifying and planning for future needs. The external radiation exposure fields are those that are documented in the WIPP Final Safety Analysis Report.« less

  14. The "Glocalization" of Medical School Accreditation: Case Studies From Taiwan, South Korea, and Japan.

    PubMed

    Ho, Ming-Jung; Abbas, Joan; Ahn, Ducksun; Lai, Chi-Wan; Nara, Nobuo; Shaw, Kevin

    2017-12-01

    In an age of globalized medical education, medical school accreditation has been hailed as an approach to external quality assurance. However, accreditation standards can vary widely across national contexts. To achieve recognition by the World Federation for Medical Education (WFME), national accrediting bodies must develop standards suitable for both local contexts and international recognition. This study framed this issue in terms of "glocalization" and aimed to shine light on this complicated multistakeholder process by exploring accreditation in Taiwan, South Korea, and Japan. This study employed a comparative case-study design, examining the national standards that three accreditation bodies in East Asia developed using international reference standards. In 2015-2016, the authors conducted document analysis of the English versions of the standards to identify the differences between the national and international reference standards as well as how and why external standards were adapted. Each country's accreditation body sought to balance local needs with global demands. Each used external standards as a template (e.g., Liaison Committee on Medical Education, General Medical Council, or WFME standards) and either revised (Taiwan, South Korea) or annotated (Japan) the standards to fit the local context. Four categories of differences emerged to account for how and why national standards departed from external references: structural, regulatory, developmental, and aspirational. These countries' glocalization of medical accreditation standards serve as examples for others seeking to bring their accreditation practices in line with global standards while ensuring that local values and societal needs are given adequate consideration.

  15. Flight design system level C requirements. Solid rocket booster and external tank impact prediction processors. [space transportation system

    NASA Technical Reports Server (NTRS)

    Seale, R. H.

    1979-01-01

    The prediction of the SRB and ET impact areas requires six separate processors. The SRB impact prediction processor computes the impact areas and related trajectory data for each SRB element. Output from this processor is stored on a secure file accessible by the SRB impact plot processor which generates the required plots. Similarly the ET RTLS impact prediction processor and the ET RTLS impact plot processor generates the ET impact footprints for return-to-launch-site (RTLS) profiles. The ET nominal/AOA/ATO impact prediction processor and the ET nominal/AOA/ATO impact plot processor generate the ET impact footprints for non-RTLS profiles. The SRB and ET impact processors compute the size and shape of the impact footprints by tabular lookup in a stored footprint dispersion data base. The location of each footprint is determined by simulating a reference trajectory and computing the reference impact point location. To insure consistency among all flight design system (FDS) users, much input required by these processors will be obtained from the FDS master data base.

  16. How External Institutions Penetrate Schools through Formal and Informal Leaders

    ERIC Educational Resources Information Center

    Sun, Min; Frank, Kenneth A.; Penuel, William R.; Kim, Chong Min

    2013-01-01

    Purposes: This study investigates the role of formal and informal leaders in the diffusion of external reforms into schools and to teachers' practices. Formal leaders are designated by their roles in the formal organization of the school (e.g., principals, department chairs, and instructional coaches) and informal leaders refer to those who do not…

  17. Improving Teaching and Learning in Higher Education: Metaphors and Models for Partnership Consultancy

    ERIC Educational Resources Information Center

    Morrison, Keith

    2003-01-01

    The management of partnerships with external consultants is discussed with reference to seven metaphors of partnership, illuminated by an external consultancy review of teaching and learning in a University Language Centre. Shortcomings are shown in each of the seven metaphors. A model of partnership is advocated, based on Habermas' principles of…

  18. Nonlinear robust control of hypersonic aircrafts with interactions between flight dynamics and propulsion systems.

    PubMed

    Li, Zhaoying; Zhou, Wenjie; Liu, Hao

    2016-09-01

    This paper addresses the nonlinear robust tracking controller design problem for hypersonic vehicles. This problem is challenging due to strong coupling between the aerodynamics and the propulsion system, and the uncertainties involved in the vehicle dynamics including parametric uncertainties, unmodeled model uncertainties, and external disturbances. By utilizing the feedback linearization technique, a linear tracking error system is established with prescribed references. For the linear model, a robust controller is proposed based on the signal compensation theory to guarantee that the tracking error dynamics is robustly stable. Numerical simulation results are given to show the advantages of the proposed nonlinear robust control method, compared to the robust loop-shaping control approach. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.

  19. Localization of Mobile Robots Using Odometry and an External Vision Sensor

    PubMed Central

    Pizarro, Daniel; Mazo, Manuel; Santiso, Enrique; Marron, Marta; Jimenez, David; Cobreces, Santiago; Losada, Cristina

    2010-01-01

    This paper presents a sensor system for robot localization based on the information obtained from a single camera attached in a fixed place external to the robot. Our approach firstly obtains the 3D geometrical model of the robot based on the projection of its natural appearance in the camera while the robot performs an initialization trajectory. This paper proposes a structure-from-motion solution that uses the odometry sensors inside the robot as a metric reference. Secondly, an online localization method based on a sequential Bayesian inference is proposed, which uses the geometrical model of the robot as a link between image measurements and pose estimation. The online approach is resistant to hard occlusions and the experimental setup proposed in this paper shows its effectiveness in real situations. The proposed approach has many applications in both the industrial and service robot fields. PMID:22319318

  20. Receptors as a master key for synchronization of rhythms

    NASA Astrophysics Data System (ADS)

    Nagano, Seido

    2004-03-01

    A simple, but general scheme to achieve synchronization of rhythms was derived. The scheme has been inductively generalized from the modelling study of cellular slime mold. It was clarified that biological receptors work as apparatuses that can convert external stimulus to the form of nonlinear interaction within individual oscillators. Namely, the mathematical model receptor works as a nonlinear coupling apparatus between nonlinear oscillators. Thus, synchronization is achieved as a result of competition between two kinds of non-linearities, and to achieve synchronization, even a small external stimulation via model receptors can change the characteristics of individual oscillators significantly. The derived scheme is very simple mathematically, but it is a very powerful scheme as numerically demonstrated. The biological receptor scheme should significantly help understanding of synchronization phenomena in biology since groups of limit cycle oscillators and receptors are ubiquitous in biological systems. Reference: S. Nagano, Phys Rev. E67, 056215(2003)

  1. Localization of mobile robots using odometry and an external vision sensor.

    PubMed

    Pizarro, Daniel; Mazo, Manuel; Santiso, Enrique; Marron, Marta; Jimenez, David; Cobreces, Santiago; Losada, Cristina

    2010-01-01

    This paper presents a sensor system for robot localization based on the information obtained from a single camera attached in a fixed place external to the robot. Our approach firstly obtains the 3D geometrical model of the robot based on the projection of its natural appearance in the camera while the robot performs an initialization trajectory. This paper proposes a structure-from-motion solution that uses the odometry sensors inside the robot as a metric reference. Secondly, an online localization method based on a sequential Bayesian inference is proposed, which uses the geometrical model of the robot as a link between image measurements and pose estimation. The online approach is resistant to hard occlusions and the experimental setup proposed in this paper shows its effectiveness in real situations. The proposed approach has many applications in both the industrial and service robot fields.

  2. SWOT analysis and revelation in traditional Chinese medicine internationalization.

    PubMed

    Tang, Haitao; Huang, Wenlong; Ma, Jimei; Liu, Li

    2018-01-01

    Traditional Chinese medicine (TCM) is currently the best-preserved and most influential traditional medical system with the largest number of users worldwide. In recent years, the trend of TCM adoption has increased greatly, but the process of TCM internationalization has suffered from a series of setbacks for both internal and external reasons. Thus, the process of TCM internationalization faces formidable challenges, although it also has favourable opportunities. Using SWOT analysis, this paper investigates the strengths, weaknesses, opportunities and threats for TCM. These findings can serve as references for TCM enterprises with global ambitions.

  3. Rambling and trembling in response to body loading.

    PubMed

    Tahayor, Behdad; Riley, Zachary A; Mahmoudian, Armaghan; Koceja, David M; Hong, Siang Lee

    2012-04-01

    Various studies have suggested that postural sway is controlled by at least two subsystems. Rambling-Trembling analysis is a widely accepted methodology to dissociate the signals generated by these two hypothetical subsystems. The core assumption of this method is based on the equilibrium point hypothesis which suggests that the central nervous system preserves upright standing by transiently shifting the center of pressure (COP) from one equilibrium point to another. The trajectory generated by this shifting is referred to as rambling and its difference from the original COP signal is referred to as trembling. In this study we showed that these two components of COP are differentially affected when standing with external loads. Using Detrended Fluctuation analysis, we compared the pattern of these two signals in different configurations of body loading. Our findings suggest that by applying an external load, the dynamics of the trembling component is altered independently of the area of postural sway and also independently of the rambling component. The dynamics of rambling changed only during the backloading condition in which the postural sway area also substantially increased. It can be suggested that during loaded standing, the trembling mechanism (which is suggested to be activated by peripheral mechanisms and reflexes) is altered without affecting the central influence on the shifts of the equilibrium point.

  4. Development of an integrated electrochemical system for in vitro yeast viability testing.

    PubMed

    Adami, Andrea; Ress, Cristina; Collini, Cristian; Pedrotti, Severino; Lorenzelli, Leandro

    2013-02-15

    This work describes the development and testing of a microfabricated sensor for rapid cell growth monitoring, especially focused on yeast quality assessment for wine applications. The device consists of a NMOS ISFET sensor with Si(3)N(4) gate, able to indirectly monitor extracellular metabolism through pH variation of the medium, and a solid-state reference electrode implemented with PVC membranes doped with lipophilic salts (tetrabutylammonium-tetrabutylborate (TBA-TBB) and Potassium tetrakis(4-chlorphenyl)borate (KTClpB)). The use of a solid state reference electrode enables the implementation of a large number of cell assays in parallel, without the need of external conventional reference electrodes. Microbial growth testing has been performed both in standard culture conditions and on chip at different concentrations of ethanol in order to carry out a commonly used screening of wine yeast strains. Cell growth tests can be performed in few hours, providing a fast, sensitive and low cost analysis with respect to the conventional procedures. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. Structure-From for Calibration of a Vehicle Camera System with Non-Overlapping Fields-Of in AN Urban Environment

    NASA Astrophysics Data System (ADS)

    Hanel, A.; Stilla, U.

    2017-05-01

    Vehicle environment cameras observing traffic participants in the area around a car and interior cameras observing the car driver are important data sources for driver intention recognition algorithms. To combine information from both camera groups, a camera system calibration can be performed. Typically, there is no overlapping field-of-view between environment and interior cameras. Often no marked reference points are available in environments, which are a large enough to cover a car for the system calibration. In this contribution, a calibration method for a vehicle camera system with non-overlapping camera groups in an urban environment is described. A-priori images of an urban calibration environment taken with an external camera are processed with the structure-frommotion method to obtain an environment point cloud. Images of the vehicle interior, taken also with an external camera, are processed to obtain an interior point cloud. Both point clouds are tied to each other with images of both image sets showing the same real-world objects. The point clouds are transformed into a self-defined vehicle coordinate system describing the vehicle movement. On demand, videos can be recorded with the vehicle cameras in a calibration drive. Poses of vehicle environment cameras and interior cameras are estimated separately using ground control points from the respective point cloud. All poses of a vehicle camera estimated for different video frames are optimized in a bundle adjustment. In an experiment, a point cloud is created from images of an underground car park, as well as a point cloud of the interior of a Volkswagen test car is created. Videos of two environment and one interior cameras are recorded. Results show, that the vehicle camera poses are estimated successfully especially when the car is not moving. Position standard deviations in the centimeter range can be achieved for all vehicle cameras. Relative distances between the vehicle cameras deviate between one and ten centimeters from tachymeter reference measurements.

  6. Sensitivity to psychosocial chronic stressors and adolescents' externalizing problems: Combined moderator effects of resting heart rate and parental psychiatric history.

    PubMed

    Zandstra, Anna Roos E; Ormel, Johan; Dietrich, Andrea; van den Heuvel, Edwin R; Hoekstra, Pieter J; Hartman, Catharina A

    2018-04-01

    From the literature it is not clear whether low resting heart rate (HR) reflects low or high sensitivity to the detrimental effects of adverse environments on externalizing problems. We studied parental psychiatric history (PH), reflecting general vulnerability, as possible moderator explaining these inconsistencies. Using Linear Mixed Models, we analyzed data from 1914 subjects, obtained in three measurement waves (mean age 11, 13.5, and 16 years) from the TRacking Adolescents' Individual Lives Survey population-based cohort and the parallel clinic-referred cohort. As hypothesized, more chronic stressors predicted more externalizing problems in vulnerable individuals with high resting HR but not in those with low resting HR, suggesting high vs. low sensitivity, respectively, to adverse environmental influences. Low sensitivity to adverse environmental influences in vulnerable individuals exposed to high stressor levels was additionally confirmed by high heart rate variability (Root Mean Squared Successive Difference; RMSSD). In adolescents with low vulnerability, in contrast, the association between chronic stressors and externalizing problems did not substantially differ by resting HR and RMSSD. Future research may demonstrate whether our findings extend to other adverse, or beneficial, influences. Notwithstanding their theoretical interest, the effects were small, only pertained to parent-reported externalizing problems, refer to a small subset of respondents in our sample, and are in need of replication. We conclude that HR and RMSSD are unlikely to be strong moderators of the association between stressors and externalizing problems. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. Neurophysiological mechanisms of emotion regulation for subtypes of externalizing children.

    PubMed

    Stieben, Jim; Lewis, Marc D; Granic, Isabela; Zelazo, Philip David; Segalowitz, Sidney; Pepler, Debra

    2007-01-01

    Children referred for externalizing behavior problems may not represent a homogeneous population. Our objective was to assess neural mechanisms of emotion regulation that might distinguish subtypes of externalizing children from each other and from their normal age mates. Children with pure externalizing (EXT) problems were compared with children comorbid for externalizing and internalizing (MIXED) problems and with age-matched controls. Only boys were included in the analysis because so few girls were referred for treatment. We used a go/no-go task with a negative emotion induction, and we examined dense-array EEG data together with behavioral measures of performance. We investigated two event-related potential (ERP) components tapping inhibitory control or self-monitoring - the inhibitory N2 and error-related negativity (ERN) - and we constructed source models estimating their cortical generators. The MIXED children's N2s increased in response to the emotion induction, resulting in greater amplitudes than EXT children in the following trial block. ERN amplitudes were greatest for control children and smallest for EXT children with MIXED children in between, but only prior to the emotion induction. These results were paralleled by behavioral differences in response time and performance monitoring. ERP activity was localized to cortical sources suggestive of the dorsal anterior cingulate for control children, posterior cingulate areas for the EXT children, and both posterior cingulate and ventral cingulate/prefrontal regions for the MIXED children. These findings highlight different mechanisms of self-regulation underlying externalizing subtypes and point toward distinct developmental pathways and treatment strategies.

  8. Proposed Oral Reference Dose (RfD) for Barium and Compounds (Final Report, 2004)

    EPA Science Inventory

    This document is the final report from the 2004 external peer review of the Proposed Oral Reference Dose (RfD) for Barium and Compounds, prepared by the U.S. Environmental Protection Agency (EPA), National Center for Environmental Assessment (NCEA), for the Integrated Risk...

  9. Finding and Addressing the Gaps: Two Evaluations of Archival Reference Services

    ERIC Educational Resources Information Center

    Battley, Belinda; Wright, Alicia

    2012-01-01

    Regular evaluation of archival reference services is essential to ensure that users have appropriate access to the information they need. Archives New Zealand has been measuring customer satisfaction for many years using self-completion questionnaires but recently trialed two new methods of evaluation, using external research companies. One…

  10. IRIS Toxicological Review and Summary Documents for Vinyl Chloride (External Review Draft)

    EPA Science Inventory

    The Draft Toxicological Review was developed to evaluate both the cancer and non cancer human health risks from environmental exposure to vinyl chloride. A reference concentration (RfC), and a reference dose (RfD) were developed based upon induction of liver cell polymorphism in ...

  11. Personality and Psychopathology in Flemish Referred Children: Five Perspectives of Continuity

    ERIC Educational Resources Information Center

    De Bolle, Marleen; De Clercq, Barbara; Van Leeuwen, Karla; Decuyper, Mieke; Rosseel, Yves; De Fruyt, Filip

    2009-01-01

    The present study investigates five types of continuity of personality and internalizing and externalizing problems (i.e., structural, differential, mean-level, individual-level and ipsative continuity) in a sample of referred children and adolescents (N = 114) with a broad variety of psychological problems. Mothers were administered a child…

  12. Test of synthetic DNA tracers in a periodic hydrodynamic system for time-variable transit time distribution assessment

    NASA Astrophysics Data System (ADS)

    Dahlke, H. E.; Wang, C.; McNew, C.; McLaughlin, S.; Lyon, S. W.

    2016-12-01

    Recent research on time-varying transport through hydrologic systems proposed using decomposed over-printed tracer breakthrough curves to directly observe transport through complex flow systems. This method, also known as the PERTH (Periodic Tracer Hierarchy) method requires periodic flow and multiple tracer injections to reveal changes in flow pathways and transport behavior. Time-variable transit time distributions (TTD) estimated from tracer breakthrough curves often vary with the storage state of the system, which in turn is influenced by internal and external variabilities, such as the arrangement of flow pathways and fluctuations in system inputs. Deciphering internal from external variabilities in TTDs might help to advance the use of TTDs for estimating the physical state of a system; however, thus far the finite number of unique conservative tracers available for tracing has limited deeper insights. Synthetic DNA tracers consisting of short strands of synthetic DNA encapsulated by polylactic acid (PLA) microspheres could potentially provide multiple unique tracers with identical transport properties needed to explore time varying transport through hydrologic systems in more detail. An experiment was conducted on the miniLeo hillslope, a 1 m3 sloping lysimeter, within the Biosphere 2 Landscape Evolution Observatory near Tucson, AZ to investigate transit time variability. The goal of the experiment was to 1) test the suitability of using synthetic DNA tracers for estimating TTDs in a hydrologic system and 2) to determine the TTDs of individual tracer pulses under periodic steady-state conditions. Five DNA tracers, consisting of four unique, encapsulated DNA sequences and one free/non-encapsulated DNA sequence, were applied as reference and probe tracers together with deuterium, using the PERTH method. The lysimeter received three 2-hour pulses of rainfall at a rate of 30 mm/hr for 10 days. Initial results show that both the encapsulated and free DNA tracers were successfully transported in a pulsed manner through the system, but had overall longer breakthrough times than the reference deuterium tracer. Comparison of the DNA probe tracers indicate differences in transit times, likely related to differences in tracer mobilization in response to the time-variant rainfall input.

  13. MEMOSys: Bioinformatics platform for genome-scale metabolic models

    PubMed Central

    2011-01-01

    Background Recent advances in genomic sequencing have enabled the use of genome sequencing in standard biological and biotechnological research projects. The challenge is how to integrate the large amount of data in order to gain novel biological insights. One way to leverage sequence data is to use genome-scale metabolic models. We have therefore designed and implemented a bioinformatics platform which supports the development of such metabolic models. Results MEMOSys (MEtabolic MOdel research and development System) is a versatile platform for the management, storage, and development of genome-scale metabolic models. It supports the development of new models by providing a built-in version control system which offers access to the complete developmental history. Moreover, the integrated web board, the authorization system, and the definition of user roles allow collaborations across departments and institutions. Research on existing models is facilitated by a search system, references to external databases, and a feature-rich comparison mechanism. MEMOSys provides customizable data exchange mechanisms using the SBML format to enable analysis in external tools. The web application is based on the Java EE framework and offers an intuitive user interface. It currently contains six annotated microbial metabolic models. Conclusions We have developed a web-based system designed to provide researchers a novel application facilitating the management and development of metabolic models. The system is freely available at http://www.icbi.at/MEMOSys. PMID:21276275

  14. A vehicle stability control strategy with adaptive neural network sliding mode theory based on system uncertainty approximation

    NASA Astrophysics Data System (ADS)

    Ji, Xuewu; He, Xiangkun; Lv, Chen; Liu, Yahui; Wu, Jian

    2018-06-01

    Modelling uncertainty, parameter variation and unknown external disturbance are the major concerns in the development of an advanced controller for vehicle stability at the limits of handling. Sliding mode control (SMC) method has proved to be robust against parameter variation and unknown external disturbance with satisfactory tracking performance. But modelling uncertainty, such as errors caused in model simplification, is inevitable in model-based controller design, resulting in lowered control quality. The adaptive radial basis function network (ARBFN) can effectively improve the control performance against large system uncertainty by learning to approximate arbitrary nonlinear functions and ensure the global asymptotic stability of the closed-loop system. In this paper, a novel vehicle dynamics stability control strategy is proposed using the adaptive radial basis function network sliding mode control (ARBFN-SMC) to learn system uncertainty and eliminate its adverse effects. This strategy adopts a hierarchical control structure which consists of reference model layer, yaw moment control layer, braking torque allocation layer and executive layer. Co-simulation using MATLAB/Simulink and AMESim is conducted on a verified 15-DOF nonlinear vehicle system model with the integrated-electro-hydraulic brake system (I-EHB) actuator in a Sine With Dwell manoeuvre. The simulation results show that ARBFN-SMC scheme exhibits superior stability and tracking performance in different running conditions compared with SMC scheme.

  15. Flexible programmable logic module

    DOEpatents

    Robertson, Perry J.; Hutchinson, Robert L.; Pierson, Lyndon G.

    2001-01-01

    The circuit module of this invention is a VME board containing a plurality of programmable logic devices (PLDs), a controlled impedance clock tree, and interconnecting buses. The PLDs are arranged to permit systolic processing of a problem by offering wide data buses and a plurality of processing nodes. The board contains a clock reference and clock distribution tree that can drive each of the PLDs with two critically timed clock references. External clock references can be used to drive additional circuit modules all operating from the same synchronous clock reference.

  16. Safety considerations for wireless delivery of continuous power to implanted medical devices.

    PubMed

    Lucke, Lori; Bluvshtein, Vlad

    2014-01-01

    Wireless power systems for use with implants are referred to as transcutaneous energy transmission systems (TETS) and consist of an implanted secondary coil and an external primary coil along with supporting electronics. A TETS system could be used to power ventricular assist systems and eliminate driveline infections. There are both direct and indirect safety concerns that must be addressed when continuously transferring power through the skin. Direct safety concerns include thermal tissue damage caused by exposure to the electromagnetic fields, coil heating effects, and potential unwanted nerve stimulation. Indirect concerns are those caused by potential interference of the TETS system with other implanted devices. Wireless power systems are trending towards higher frequency operation. Understanding the limits for safe operation of a TETS system across a range of frequencies is important. A low frequency and a high frequency implementation are simulated to demonstrate the impact of this trend for a VAD application.

  17. Input-output identification of controlled discrete manufacturing systems

    NASA Astrophysics Data System (ADS)

    Estrada-Vargas, Ana Paula; López-Mellado, Ernesto; Lesage, Jean-Jacques

    2014-03-01

    The automated construction of discrete event models from observations of external system's behaviour is addressed. This problem, often referred to as system identification, allows obtaining models of ill-known (or even unknown) systems. In this article, an identification method for discrete event systems (DESs) controlled by a programmable logic controller is presented. The method allows processing a large quantity of observed long sequences of input/output signals generated by the controller and yields an interpreted Petri net model describing the closed-loop behaviour of the automated DESs. The proposed technique allows the identification of actual complex systems because it is sufficiently efficient and well adapted to cope with both the technological characteristics of industrial controllers and data collection requirements. Based on polynomial-time algorithms, the method is implemented as an efficient software tool which constructs and draws the model automatically; an overview of this tool is given through a case study dealing with an automated manufacturing system.

  18. [Phosphoric acid ester preparations used in cattle, swine and sheep with special reference to cholinesterase activity. 4. Use of phosphoric acid esters and their effect on acetylcholinesterase activity in sheep].

    PubMed

    Mieth, K; Beier, D; Losch, K

    1975-01-01

    The use of organophosphorus preparations for the control of ectoparasites and endoparasites of sheep, particularly systemic application, is discussed. Experiments on 13 groups of sheep with five preparations produced in the German Democratic Republic in various formulations and concentrations showed that external application had good contact activity, but little was absorbed. Acetylcholinesterase activity was not inhibited, except by pour-on application of doses several times the normal dose. The preparations were arranged in order of cholinesterase inhibition. In contrast to cattle, diminished cholinesterase activity was unreliable as in indicator of systemic toxicity of organophosphorus preparations in sheep.

  19. Photophobia

    MedlinePlus

    ... sensitivity; Vision - light sensitive; Eyes - sensitivity to light Images External and internal eye anatomy References Ehlers W, Suchecki J, Steinemann TL, Donshik P. Contact lens-related complications. ...

  20. Wind-Tunnel Research Comparing Lateral Control Devices Particularly at High Angles of Attack XIII : Auxiliary Airfoils Used as External Ailerons

    NASA Technical Reports Server (NTRS)

    Weick, Fred E; Noyes, Richard W

    1936-01-01

    This is the thirteenth report on a series of systematic tests comparing lateral control devices with particular reference to their effectiveness at high angles of attack. The present wind tunnel tests were made to determine the most feasible locations for lateral control surfaces mounted externally to a rectangular Clark y wing.

  1. Pearls and pitfalls of deformity correction and limb lengthening via monolateral external fixation.

    PubMed Central

    Noonan, K. J.; Price, C. T.

    1996-01-01

    In conclusion, monolateral external fixation can be effectively utilized in the management of limb length discrepancy and angular deformity. This manuscript outlines the pertinent theory, application and problems important in these cases. When faced with specific congenital conditions the surgeon is encouraged to reference relevant literature that is more focused than the current paper. PMID:9129275

  2. Together, Slowly but Surely: The Role of Social Interaction and Feedback on the Build-Up of Benefit in Collective Decision-Making

    ERIC Educational Resources Information Center

    Bahrami, Bahador; Olsen, Karsten; Bang, Dan; Roepstorff, Andreas; Rees, Geraint; Frith, Chris

    2012-01-01

    That objective reference is necessary for formation of reliable beliefs about the external world is almost axiomatic. However, Condorcet (1785) suggested that purely subjective information--if shared and combined via social interaction--is enough for accurate understanding of the external world. We asked if social interaction and objective…

  3. Assessment of Reference Height Models on Quality of Tandem-X dem

    NASA Astrophysics Data System (ADS)

    Mirzaee, S.; Motagh, M.; Arefi, H.

    2015-12-01

    The aim of this study is to investigate the effect of various Global Digital Elevation Models (GDEMs) in producing high-resolution topography model using TanDEM-X (TDX) Coregistered Single Look Slant Range Complex (CoSSC) images. We selected an image acquired on Jun 12th, 2012 over Doroud region in Lorestan, west of Iran and used 4 external digital elevation models in our processing including DLR/ASI X-SAR DEM (SRTM-X, 30m resolution), ASTER GDEM Version 2 (ASTER-GDEMV2, 30m resolution), NASA SRTM Version 4 (SRTM-V4, 90m resolution), and a local photogrammetry-based DEM prepared by National Cartographic Center (NCC DEM, 10m resolution) of Iran. InSAR procedure for DEM generation was repeated four times with each of the four external height references. The quality of each external DEM was initially assessed using ICESat filtered points. Then, the quality of, each TDX-based DEM was assessed using the more precise external DEM selected in the previous step. Results showed that both local (NCC) DEM and SRTM X-band performed the best (RMSE< 9m) for TDX-DEM generation. In contrast, ASTER GDEM v2 and SRTM C-band v4 showed poorer quality.

  4. Contextual cueing of tactile search is coded in an anatomical reference frame.

    PubMed

    Assumpção, Leonardo; Shi, Zhuanghua; Zang, Xuelian; Müller, Hermann J; Geyer, Thomas

    2018-04-01

    This work investigates the reference frame(s) underlying tactile context memory, a form of statistical learning in a tactile (finger) search task. In this task, if a searched-for target object is repeatedly encountered within a stable spatial arrangement of task-irrelevant distractors, detecting the target becomes more efficient over time (relative to nonrepeated arrangements), as learned target-distractor spatial associations come to guide tactile search, thus cueing attention to the target location. Since tactile search displays can be represented in several reference frames, including multiple external and an anatomical frame, in Experiment 1 we asked whether repeated search displays are represented in tactile memory with reference to an environment-centered or anatomical reference frame. In Experiment 2, we went on examining a hand-centered versus anatomical reference frame of tactile context memory. Observers performed a tactile search task, divided into a learning and test session. At the transition between the two sessions, we introduced postural manipulations of the hands (crossed ↔ uncrossed in Expt. 1; palm-up ↔ palm-down in Expt. 2) to determine the reference frame of tactile contextual cueing. In both experiments, target-distractor associations acquired during learning transferred to the test session when the placement of the target and distractors was held constant in anatomical, but not external, coordinates. In the latter, RTs were even slower for repeated displays. We conclude that tactile contextual learning is coded in an anatomical reference frame. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  5. Error-enhancing robot therapy to induce motor control improvement in childhood onset primary dystonia.

    PubMed

    Casellato, Claudia; Pedrocchi, Alessandra; Zorzi, Giovanna; Rizzi, Giorgio; Ferrigno, Giancarlo; Nardocci, Nardo

    2012-07-23

    Robot-generated deviating forces during multijoint reaching movements have been applied to investigate motor control and to tune neuromotor adaptation. Can the application of force to limbs improve motor learning? In this framework, the response to altered dynamic environments of children affected by primary dystonia has never been studied. As preliminary pilot study, eleven children with primary dystonia and eleven age-matched healthy control subjects were asked to perform upper limb movements, triangle-reaching (three directions) and circle-writing, using a haptic robot interacting with ad-hoc developed task-specific visual interfaces. Three dynamic conditions were provided, null additive external force (A), constant disturbing force (B) and deactivation of the additive external force again (C). The path length for each trial was computed, from the recorded position data and interaction events. The results show that the disturbing force affects significantly the movement outcomes in healthy but not in dystonic subjects, already compromised in the reference condition: the external alteration uncalibrates the healthy sensorimotor system, while the dystonic one is already strongly uncalibrated. The lack of systematic compensation for perturbation effects during B condition is reflected into the absence of after-effects in C condition, which would be the evidence that CNS generates a prediction of the perturbing forces using an internal model of the environment.The most promising finding is that in dystonic population the altered dynamic exposure seems to induce a subsequent improvement, i.e. a beneficial after-effect in terms of optimal path control, compared with the correspondent reference movement outcome. The short-time error-enhancing training in dystonia could represent an effective approach for motor performance improvement, since the exposure to controlled dynamic alterations induces a refining of the existing but strongly imprecise motor scheme and sensorimotor patterns.

  6. Error-enhancing robot therapy to induce motor control improvement in childhood onset primary dystonia

    PubMed Central

    2012-01-01

    Background Robot-generated deviating forces during multijoint reaching movements have been applied to investigate motor control and to tune neuromotor adaptation. Can the application of force to limbs improve motor learning? In this framework, the response to altered dynamic environments of children affected by primary dystonia has never been studied. Methods As preliminary pilot study, eleven children with primary dystonia and eleven age-matched healthy control subjects were asked to perform upper limb movements, triangle-reaching (three directions) and circle-writing, using a haptic robot interacting with ad-hoc developed task-specific visual interfaces. Three dynamic conditions were provided, null additive external force (A), constant disturbing force (B) and deactivation of the additive external force again (C). The path length for each trial was computed, from the recorded position data and interaction events. Results The results show that the disturbing force affects significantly the movement outcomes in healthy but not in dystonic subjects, already compromised in the reference condition: the external alteration uncalibrates the healthy sensorimotor system, while the dystonic one is already strongly uncalibrated. The lack of systematic compensation for perturbation effects during B condition is reflected into the absence of after-effects in C condition, which would be the evidence that CNS generates a prediction of the perturbing forces using an internal model of the environment. The most promising finding is that in dystonic population the altered dynamic exposure seems to induce a subsequent improvement, i.e. a beneficial after-effect in terms of optimal path control, compared with the correspondent reference movement outcome. Conclusions The short-time error-enhancing training in dystonia could represent an effective approach for motor performance improvement, since the exposure to controlled dynamic alterations induces a refining of the existing but strongly imprecise motor scheme and sensorimotor patterns. PMID:22824547

  7. 40 CFR 53.63 - Test procedure: Wind tunnel inlet aspiration test.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... the sampler inlet opening centered in the sampling zone. To meet the maximum blockage limit of § 53.62(c)(1) or for convenience, part of the test sampler may be positioned external to the wind tunnel... = reference method sampler volumetric flow rate; and t = sampling time. (iii) Remove the reference method...

  8. Dissipation, generalized free energy, and a self-consistent nonequilibrium thermodynamics of chemically driven open subsystems.

    PubMed

    Ge, Hao; Qian, Hong

    2013-06-01

    Nonequilibrium thermodynamics of a system situated in a sustained environment with influx and efflux is usually treated as a subsystem in a larger, closed "universe." A question remains with regard to what the minimally required description for the surrounding of such an open driven system is so that its nonequilibrium thermodynamics can be established solely based on the internal stochastic kinetics. We provide a solution to this problem using insights from studies of molecular motors in a chemical nonequilibrium steady state (NESS) with sustained external drive through a regenerating system or in a quasisteady state (QSS) with an excess amount of adenosine triphosphate (ATP), adenosine diphosphate (ADP), and inorganic phosphate (Pi). We introduce the key notion of minimal work that is needed, W(min), for the external regenerating system to sustain a NESS (e.g., maintaining constant concentrations of ATP, ADP and Pi for a molecular motor). Using a Markov (master-equation) description of a motor protein, we illustrate that the NESS and QSS have identical kinetics as well as the second law in terms of the same positive entropy production rate. The heat dissipation of a NESS without mechanical output is exactly the W(min). This provides a justification for introducing an ideal external regenerating system and yields a free-energy balance equation between the net free-energy input F(in) and total dissipation F(dis) in an NESS: F(in) consists of chemical input minus mechanical output; F(dis) consists of dissipative heat, i.e. the amount of useful energy becoming heat, which also equals the NESS entropy production. Furthermore, we show that for nonstationary systems, the F(dis) and F(in) correspond to the entropy production rate and housekeeping heat in stochastic thermodynamics and identify a relative entropy H as a generalized free energy. We reach a new formulation of Markovian nonequilibrium thermodynamics based on only the internal kinetic equation without further reference to the intrinsic degree of freedom within each Markov state. It includes an extended free-energy balance and a second law which are valid for driven stochastic dynamics with an ideal external regenerating system. Our result suggests new ingredients for a generalized thermodynamics of self-organization in driven systems.

  9. Social cognition and externalizing psychopathology: an investigation of the mediating role of language.

    PubMed

    Zadeh, Zohreh Yaghoub; Im-Bolter, Nancie; Cohen, Nancy J

    2007-04-01

    The present study integrates findings from three lines of research on the association of social cognition and externalizing psychopathology, language and externalizing psychopathology, and social cognition and language functioning using Structural Equation Modeling (SEM). To date these associations have been examined in pairs. A sample of 354 clinic-referred children (aged 7 to 14 years) recruited from a children's mental health centre were tested on measures of language, social cognition, working memory, and child psychopathology. We compared a hypothesized model presenting language functioning as a mediator of the association between social cognition and externalizing psychopathology to a model presenting the independent contribution of language and social cognition to externalizing psychopathology. As hypothesized, we found that the mediation model fits the data better than the alternative model. Our findings have implications for developing and modifying intervention techniques for children with dual language and externalizing psychopathology.

  10. In vitro tympanic membrane position identification with a co-axial fiber-optic otoscope

    NASA Astrophysics Data System (ADS)

    Sundberg, Mikael; Peebo, Markus; Strömberg, Tomas

    2011-09-01

    Otitis media diagnosis can be assisted by measuring the shape of the tympanic membrane. We have developed an ear speculum for an otoscope, including spatially distributed source and detector optical fibers, to generate source-detector intensity matrices (SDIMs), representing the curvature of surfaces. The surfaces measured were a model ear with a latex membrane and harvested temporal bones including intact tympanic membranes. The position of the tympanic membrane was shifted from retracted to bulging by air pressure and that of the latex membrane by water displacement. The SDIM was normalized utilizing both external (a sheared flat plastic cylinder) and internal references (neutral position of the membrane). Data was fitted to a two-dimensional Gaussian surface representing the shape by its amplitude and offset. Retracted and bulging surfaces were discriminated for the model ear by the sign of the Gaussian amplitude for both internal and external reference normalization. Tympanic membranes were separated after a two-step normalization: first to an external reference, adjusted for the distance between speculum and the surfaces, and second by comparison with an average normally positioned SDIM from tympanic membranes. In conclusion, we have shown that the modified otoscope can discriminate between bulging and retracted tympanic membranes in a single measurement, given a two-step normalization.

  11. Improved child behavioural and emotional functioning after Circle of Security 20-week intervention.

    PubMed

    Huber, Anna; McMahon, Catherine; Sweller, Naomi

    2015-01-01

    This study examined the efficacy of the attachment-based Circle of Security 20-week intervention in improving child behavioural and emotional functioning. Participants were 83 parents of children (1-7 years) referred to a clinical service with concerns about their young children's behaviour. Parents (and teachers, when available) completed questionnaires assessing child protective factors, behavioural concerns, internalizing and externalizing problems, prior to and immediately after the intervention. The following were considered as potential moderators: child gender and age, parent representations, reflective functioning, child attachment indices and severity of presenting problems, prior to treatment. Results showed significant improvement for parent ratings of child protective factors, behavioural concerns, internalizing and externalizing symptoms, all ps < .05, and children with more severe problems showed most improvement. Teachers also reported improvements, but change was significant only for externalizing problems (p = .030). Findings suggest Circle of Security is effective in improving child behavioural and emotional functioning in clinically referred children aged 1-7 years.

  12. Analyses of Radiation and Mesothelioma in the US Transuranium and Uranium Registries

    PubMed Central

    Fulcher, Keri; Nagarajan, Sumitha; McCord, Stacey; Fallahian, Naz Afarin; Hoffman, Heather J.; Haver, Cary; Tolmachev, Sergei

    2013-01-01

    Objectives. We examined the relationship between radiation and excess deaths from mesothelioma among deceased nuclear workers who were part of the US Transuranium and Uranium Registries. Methods. We performed univariate analysis with SAS Version 9.1 software. We conducted proportionate mortality ratio (PMR) and proportionate cancer mortality ratio (PCMR) analyses using the National Institute for Occupational Safety and Health Life Table Analysis System with the referent group being all deaths in the United States. Results. We found a PMR of 62.40 (P < .05) and a PCMR of 46.92 (P < .05) for mesothelioma. PMRs for the 4 cumulative external radiation dose quartiles were 61.83, 57.43, 74.46, and 83.31. PCMRs were 36.16, 47.07, 51.35, and 67.73. The PMR and PCMR for trachea, bronchus, and lung cancer were not significantly elevated. Conclusions. The relationship between cumulative external radiation dose and the PMR and PCMR for mesothelioma suggests that external radiation at nuclear facilities is associated with an increased risk of mesothelioma. The lack of a significantly elevated PMR and PCMR for trachea, bronchus, and lung cancer suggests that asbestos did not confound this relationship. PMID:23409888

  13. JXTA: A Technology Facilitating Mobile P2P Health Management System

    PubMed Central

    Rajkumar, Rajasekaran; Nallani Chackravatula Sriman, Narayana Iyengar

    2012-01-01

    Objectives Mobile JXTA (Juxtapose) gaining momentum and has attracted the interest of doctors and patients through P2P service that transmits messages. Audio and video can also be transmitted through JXTA. The use of mobile streaming mechanism with the support of mobile hospital management and healthcare system would enable better interaction between doctors, nurses, and the hospital. Experimental results demonstrate good performance in comparison with conventional systems. This study evaluates P2P JXTA/JXME (JXTA functionality to MIDP devices.) which facilitates peer-to-peer application+ using mobile-constraint devices. Also a proven learning algorithm was used to automatically send and process sorted patient data to nurses. Methods From December 2010 to December 2011, a total of 500 patients were referred to our hospital due to minor health problems and were monitored. We selected all of the peer groups and the control server, which controlled the BMO (Block Medical Officer) peer groups and BMO through the doctor peer groups, and prescriptions were delivered to the patient’s mobile phones through the JXTA/ JXME network. Results All 500 patients were registered in the JXTA network. Among these, 300 patient histories were referred to the record peer group by the doctors, 100 patients were referred to the external doctor peer group, and 100 patients were registered as new users in the JXTA/JXME network. Conclusion This system was developed for mobile streaming applications and was designed to support the mobile health management system using JXTA/ JXME. The simulated results show that this system can carry out streaming audio and video applications. Controlling and monitoring by the doctor peer group makes the system more flexible and structured. Enhanced studies are needed to improve knowledge mining and cloud-based M health management technology in comparison with the traditional system. PMID:24159509

  14. A reference-modified density functional theory: An application to solvation free-energy calculations for a Lennard-Jones solution.

    PubMed

    Sumi, Tomonari; Maruyama, Yutaka; Mitsutake, Ayori; Koga, Kenichiro

    2016-06-14

    In the conventional classical density functional theory (DFT) for simple fluids, an ideal gas is usually chosen as the reference system because there is a one-to-one correspondence between the external field and the density distribution function, and the exact intrinsic free-energy functional is available for the ideal gas. In this case, the second-order density functional Taylor series expansion of the excess intrinsic free-energy functional provides the hypernetted-chain (HNC) approximation. Recently, it has been shown that the HNC approximation significantly overestimates the solvation free energy (SFE) for an infinitely dilute Lennard-Jones (LJ) solution, especially when the solute particles are several times larger than the solvent particles [T. Miyata and J. Thapa, Chem. Phys. Lett. 604, 122 (2014)]. In the present study, we propose a reference-modified density functional theory as a systematic approach to improve the SFE functional as well as the pair distribution functions. The second-order density functional Taylor series expansion for the excess part of the intrinsic free-energy functional in which a hard-sphere fluid is introduced as the reference system instead of an ideal gas is applied to the LJ pure and infinitely dilute solution systems and is proved to remarkably improve the drawbacks of the HNC approximation. Furthermore, the third-order density functional expansion approximation in which a factorization approximation is applied to the triplet direct correlation function is examined for the LJ systems. We also show that the third-order contribution can yield further refinements for both the pair distribution function and the excess chemical potential for the pure LJ liquids.

  15. A new concept and classification of corona mortis and its clinical significance.

    PubMed

    Al Talalwah, Waseem

    2016-10-01

    The obturator artery and its accessory (aberrant) arising from different origins and crossing the pubic rami are vascular variations. The internal iliac artery usually provides the obturator artery which may communicates with the external iliac artery through either the accessory obturator or inferior epigastric artery. A collateral circulation between the external and internal iliac system is known as corona mortis. The aim of current study is to provide sufficient data of vascular variability crossing the pubic rami for clinical field. Present study includes 208 hemipelvises dissected in the Institution of Anatomy, Medical University of Graz. During dissection, the obturator artery and its accessory crossing the superior rami of pubic bone were found to have different origins. The obturator artery arising from the external iliac artery and from the femoral artery accounts for 9.8% and 1.1% respectively. Therefore, it passes over the superior pubic rami in 10.9%. Further, the accessory (aberrant) artery arises only from the femoral artery in 1.1%. In present study, the vascular variation crossing the superior pubic rami with or without collateral circulation between external and internal iliac system referred as corona mortis is addressed. This study includes new classification of obturator and accessory obturator arteries as well as the corona mortis. It includes a comparison of corona mortis incidence in Austria population and other populations. The corona mortis found to be in 12% of Austrian population. A great attention of clinicians, radiologists, surgeons, orthopedic surgeons, obstetricians and gynecologists has to be considered before pubic surgical procedures such as internal fixation of pubic fracture, an inguinal hernia repair. Further, traumatic pubic rami fracture may lead to massive hemor- rhage due to laceration of the obturator artery.

  16. No Metallicity Correlation Associated with the Kepler Dichotomy

    NASA Astrophysics Data System (ADS)

    Munoz Romero, Carlos Eduardo; Kempton, Eliza

    2018-01-01

    NASA’s Kepler mission has discovered thousands of planetary systems, ∼ 20% of which are found to host multiple transiting planets. This relative paucity (compared to the high fraction of single transiting systems) is postulated to result from a distinction in the architecture between multi-transiting systems and those hosting a single transiting planet: a phenomenon usually referred to as the Kepler dichotomy. We investigate the hypothesis that external giant planets are the main cause behind the over-abundance of single- relative to multi-transiting systems, which would be signaled by higher metallicities in the former sample. To this end, we perform a statistical analysis on the stellar metallicity distribution with respect to planet multiplicity in the Kepler data. We perform our analysis on a variety of samples taken from a population of 1062 Kepler main sequence planetary hosts, using precisely determined metallicities from the California-Kepler survey. Contrary to some predictions, we do not find a significant difference between the stellar metallicities of the single- and multiple-transiting planet systems. However, we do find a 43% upper bound for systems with a single non-giant planet that could also host a hidden giant planet, based on metallicity considerations. While the presence of external giant planets might be one factor behind the Kepler dichotomy, our results also favor alternative explanations. We suggest that additional radial velocity and direct imaging measurements are necessary to constrain the presence of gas giants in systems with a single transiting planet.

  17. Evaluating Learners's Ability to Use Technology in Distance Education: The Case of External Degree Programme of the University of Nairobi

    ERIC Educational Resources Information Center

    Omito, Ouma

    2016-01-01

    The study was aimed at investigating the students' ability to use technology for distance education with specific reference to the University of Nairobi's External Degree Program. To achieve this, one specific objective was formulated: To find out the student teacher's readiness to accept and utilize technology for learning purposes in relation to…

  18. Minimizing the Disruptive Effects of Prospective Memory in Simulated Air Traffic Control

    PubMed Central

    Loft, Shayne; Smith, Rebekah E.; Remington, Roger

    2015-01-01

    Prospective memory refers to remembering to perform an intended action in the future. Failures of prospective memory can occur in air traffic control. In two experiments, we examined the utility of external aids for facilitating air traffic management in a simulated air traffic control task with prospective memory requirements. Participants accepted and handed-off aircraft and detected aircraft conflicts. The prospective memory task involved remembering to deviate from a routine operating procedure when accepting target aircraft. External aids that contained details of the prospective memory task appeared and flashed when target aircraft needed acceptance. In Experiment 1, external aids presented either adjacent or non-adjacent to each of the 20 target aircraft presented over the 40min test phase reduced prospective memory error by 11% compared to a condition without external aids. In Experiment 2, only a single target aircraft was presented a significant time (39min–42min) after presentation of the prospective memory instruction, and the external aids reduced prospective memory error by 34%. In both experiments, costs to the efficiency of non-prospective memory air traffic management (non-target aircraft acceptance response time, conflict detection response time) were reduced by non-adjacent aids compared to no aids or adjacent aids. In contrast, in both experiments, the efficiency of the prospective memory air traffic management (target aircraft acceptance response time) was facilitated by adjacent aids compared to non-adjacent aids. Together, these findings have potential implications for the design of automated alerting systems to maximize multi-task performance in work settings where operators monitor and control demanding perceptual displays. PMID:24059825

  19. Longwall Guidance and Control Development

    NASA Technical Reports Server (NTRS)

    1982-01-01

    The longwall guidance and control (G&C) system was evaluated to determine which systems and subsystems lent themselves to automatic control in the mining of coal. The upper coal/shale interface was identified as the reference for a vertical G&C system, with two sensors (the natural backgound and the sensitized pick) being used to locate and track this boundary. In order to insure a relatively smooth recession surface (roof and floor of the excavated seam), a last and present cut measuring instrument (acoustic sensor) was used. Potentiometers were used to measure elevations of the shearer arms. The intergration of these components comprised the vertical control system (pitch control). Yaw and roll control were incorporated into a face alignment system which was designed to keep the coal face normal to its external boundaries. Numerous tests, in the laboratory and in the field, have confirmed the feasibility of automatic horizon control, as well as determining the face alignment.

  20. Design verification of large time constant thermal shields for optical reference cavities.

    PubMed

    Zhang, J; Wu, W; Shi, X H; Zeng, X Y; Deng, K; Lu, Z H

    2016-02-01

    In order to achieve high frequency stability in ultra-stable lasers, the Fabry-Pérot reference cavities shall be put inside vacuum chambers with large thermal time constants to reduce the sensitivity to external temperature fluctuations. Currently, the determination of thermal time constants of vacuum chambers is based either on theoretical calculation or time-consuming experiments. The first method can only apply to simple system, while the second method will take a lot of time to try out different designs. To overcome these limitations, we present thermal time constant simulation using finite element analysis (FEA) based on complete vacuum chamber models and verify the results with measured time constants. We measure the thermal time constants using ultrastable laser systems and a frequency comb. The thermal expansion coefficients of optical reference cavities are precisely measured to reduce the measurement error of time constants. The simulation results and the experimental results agree very well. With this knowledge, we simulate several simplified design models using FEA to obtain larger vacuum thermal time constants at room temperature, taking into account vacuum pressure, shielding layers, and support structure. We adopt the Taguchi method for shielding layer optimization and demonstrate that layer material and layer number dominate the contributions to the thermal time constant, compared with layer thickness and layer spacing.

  1. Observed Interactions Indicate Protective Effects of Relationships with Parents for Referred Adolescents

    ERIC Educational Resources Information Center

    Willemen, Agnes M.; Schuengel, Carlo; Koot, Hans M.

    2011-01-01

    This study examined whether the quality of parent-adolescent interactions moderate the association between stressful life events and internalizing and externalizing problems in referred adolescents (N = 101, M age 13.41 years, SD = 1.81). Adolescents and their parents reported on psychological problems at the time of referral and 4 years later. At…

  2. Quantum frames

    NASA Astrophysics Data System (ADS)

    Brown, Matthew J.

    2014-02-01

    The framework of quantum frames can help unravel some of the interpretive difficulties i the foundation of quantum mechanics. In this paper, I begin by tracing the origins of this concept in Bohr's discussion of quantum theory and his theory of complementarity. Engaging with various interpreters and followers of Bohr, I argue that the correct account of quantum frames must be extended beyond literal space-time reference frames to frames defined by relations between a quantum system and the exosystem or external physical frame, of which measurement contexts are a particularly important example. This approach provides superior solutions to key EPR-type measurement and locality paradoxes.

  3. UH-60A External Stores Support System Fixed Provision Fairings Drag Determination

    DTIC Science & Technology

    1984-05-01

    irori I Sif Iii. ,,moin’!1.tIit~l -,v- .v.t m ;Irttiit or oiut poit pon , it ons~ 11 r;i1 Tfre, ion, 1 Aii𔃻u’ of ; i rI Jp ~ur ra f t a ttirue Ptti’b...ltoin in ha I I cenrte red f li ght by refer. n4,41 . ’I e .v ifr.i if Ilateral I cci’ I ercmet er at a p rede te~rmi ntd rCr "’nf I Itr f’ F- rsit or

  4. Outline of Toshiba Business Information Center

    NASA Astrophysics Data System (ADS)

    Nagata, Yoshihiro

    Toshiba Business Information Center gathers and stores inhouse and external business information used in common within the Toshiba Corp., and provides companywide circulation, reference and other services. The Center established centralized information management system by employing decentralized computers, electronic file apparatus (30cm laser disc) and other office automation equipments. Online retrieval through LAN is available to search the stored documents and increasing copying requests are processed by electronic file. This paper describes the purpose of establishment of the Center, the facilities, management scheme, systematization of the files and the present situation and plan of each information service.

  5. Thermal properties of alkali-activated aluminosilicates

    NASA Astrophysics Data System (ADS)

    Florian, Pavel; Valentova, Katerina; Fiala, Lukas; Zmeskal, Oldrich

    2017-07-01

    The paper is focused on measurements and evaluation of thermal properties of alkali-activated aluminosilicates (AAA) with various carbon admixtures. Such composites consisting of blast-furnace slag, quartz sand, water glass as alkali activator and small amount of electrically conductive carbon admixture exhibit better electric and thermal properties than the reference material. Such enhancement opens up new practical applications, such as designing of snow-melting, de-icing or self-sensing systems that do not need any external sensors to detect current condition of building material. Thermal properties of the studied materials were measured by the step-wise transient method and mutually compared.

  6. The vestibular system: a spatial reference for bodily self-consciousness

    PubMed Central

    Pfeiffer, Christian; Serino, Andrea; Blanke, Olaf

    2014-01-01

    Self-consciousness is the remarkable human experience of being a subject: the “I”. Self-consciousness is typically bound to a body, and particularly to the spatial dimensions of the body, as well as to its location and displacement in the gravitational field. Because the vestibular system encodes head position and movement in three-dimensional space, vestibular cortical processing likely contributes to spatial aspects of bodily self-consciousness. We review here recent data showing vestibular effects on first-person perspective (the feeling from where “I” experience the world) and self-location (the feeling where “I” am located in space). We compare these findings to data showing vestibular effects on mental spatial transformation, self-motion perception, and body representation showing vestibular contributions to various spatial representations of the body with respect to the external world. Finally, we discuss the role for four posterior brain regions that process vestibular and other multisensory signals to encode spatial aspects of bodily self-consciousness: temporoparietal junction, parietoinsular vestibular cortex, ventral intraparietal region, and medial superior temporal region. We propose that vestibular processing in these cortical regions is critical in linking multisensory signals from the body (personal and peripersonal space) with external (extrapersonal) space. Therefore, the vestibular system plays a critical role for neural representations of spatial aspects of bodily self-consciousness. PMID:24860446

  7. Computation of high Reynolds number internal/external flows

    NASA Technical Reports Server (NTRS)

    Cline, M. C.; Wilmoth, R. G.

    1981-01-01

    A general, user oriented computer program, called VNAP2, has been developed to calculate high Reynolds number, internal/external flows. VNAP2 solves the two-dimensional, time-dependent Navier-Stokes equations. The turbulence is modeled with either a mixing-length, a one transport equation, or a two transport equation model. Interior grid points are computed using the explicit MacCormack scheme with special procedures to speed up the calculation in the fine grid. All boundary conditions are calculated using a reference plane characteristic scheme with the viscous terms treated as source terms. Several internal, and internal/external flow calculations are presented.

  8. [Multi-Target Recognition of Internal and External Defects of Potato by Semi-Transmission Hyperspectral Imaging and Manifold Learning Algorithm].

    PubMed

    Huang, Tao; Li, Xiao-yu; Jin, Rui; Ku, Jing; Xu, Sen-miao; Xu, Meng-ling; Wu, Zhen-zhong; Kong, De-guo

    2015-04-01

    The present paper put forward a non-destructive detection method which combines semi-transmission hyperspectral imaging technology with manifold learning dimension reduction algorithm and least squares support vector machine (LSSVM) to recognize internal and external defects in potatoes simultaneously. Three hundred fifteen potatoes were bought in farmers market as research object, and semi-transmission hyperspectral image acquisition system was constructed to acquire the hyperspectral images of normal external defects (bud and green rind) and internal defect (hollow heart) potatoes. In order to conform to the actual production, defect part is randomly put right, side and back to the acquisition probe when the hyperspectral images of external defects potatoes are acquired. The average spectrums (390-1,040 nm) were extracted from the region of interests for spectral preprocessing. Then three kinds of manifold learning algorithm were respectively utilized to reduce the dimension of spectrum data, including supervised locally linear embedding (SLLE), locally linear embedding (LLE) and isometric mapping (ISOMAP), the low-dimensional data gotten by manifold learning algorithms is used as model input, Error Correcting Output Code (ECOC) and LSSVM were combined to develop the multi-target classification model. By comparing and analyzing results of the three models, we concluded that SLLE is the optimal manifold learning dimension reduction algorithm, and the SLLE-LSSVM model is determined to get the best recognition rate for recognizing internal and external defects potatoes. For test set data, the single recognition rate of normal, bud, green rind and hollow heart potato reached 96.83%, 86.96%, 86.96% and 95% respectively, and he hybrid recognition rate was 93.02%. The results indicate that combining the semi-transmission hyperspectral imaging technology with SLLE-LSSVM is a feasible qualitative analytical method which can simultaneously recognize the internal and external defects potatoes and also provide technical reference for rapid on-line non-destructive detecting of the internal and external defects potatoes.

  9. The capacitive proximity sensor based on transients in RC-circuits

    NASA Astrophysics Data System (ADS)

    Yakunin, A. G.

    2018-05-01

    The principle of operation of the capacitive proximity sensor is described. It can be used in various robotic complexes, automation systems and alarm devices to inform the control device of the approach to the sensor sensitive surface of an object. At the heart of the device is the measurement of the change in the current of the transient accompanying the charge of the reference capacitor because of the parallel connection to it the capacitance formed by the sensitive sensor surface and the external object. At the heart of the device is the measurement of the change in the current of the transient accompanying the charge of the reference capacitor caused by the parallel connection to it the capacitance formed by the sensitive sensor surface and the external object. As shown by theoretical and experimental studies, the value of this capacity, depending on the purpose of the device, can vary within very wide limits. In this case, the sensitive surface can be both a piece of ordinary wire several centimeters long, and a metall plate or grid, the area of which can reach units and even tens of square meters. The main advantage of the proposed solution is a significant reduction in the effect of spurious leakage currents arising at the capacitance of the measuring electrode under the influence of pollution and humidity of the environment.

  10. Certified Reference Material for Use in 1H, 31P, and 19F Quantitative NMR, Ensuring Traceability to the International System of Units.

    PubMed

    Rigger, Romana; Rück, Alexander; Hellriegel, Christine; Sauermoser, Robert; Morf, Fabienne; Breitruck, KathrinBreitruck; Obkircher, Markus

    2017-09-01

    In recent years, quantitative NMR (qNMR) spectroscopy has become one of the most important tools for content determination of organic substances and quantitative evaluation of impurities. Using Certified Reference Materials (CRMs) as internal or external standards, the extensively used qNMR method can be applied for purity determination, including unbroken traceability to the International System of Units (SI). The implementation of qNMR toward new application fields, e.g., metabolomics, environmental analysis, and physiological pathway studies, brings along more complex molecules and systems, thus making use of 1H qNMR challenging. A smart workaround is possible by the use of other NMR active nuclei, namely 31P and 19F. This article presents the development of three classes of qNMR CRMs based on different NMR active nuclei (1H, 31P, and 19F), and the corresponding approaches to establish traceability to the SI through primary CRMs from the National Institute of Standards and Technology and the National Metrology Institute of Japan. These TraceCERT® qNMR CRMs are produced under ISO/IEC 17025 and ISO Guide 34 using high-performance qNMR.

  11. CMOS compatible fabrication process of MEMS resonator for timing reference and sensing application

    NASA Astrophysics Data System (ADS)

    Huynh, Duc H.; Nguyen, Phuong D.; Nguyen, Thanh C.; Skafidas, Stan; Evans, Robin

    2015-12-01

    Frequency reference and timing control devices are ubiquitous in electronic applications. There is at least one resonator required for each of this device. Currently electromechanical resonators such as crystal resonator, ceramic resonator are the ultimate choices. This tendency will probably keep going for many more years. However, current market demands for small size, low power consumption, cheap and reliable products, has divulged many limitations of this type of resonators. They cannot be integrated into standard CMOS (Complement metaloxide- semiconductor) IC (Integrated Circuit) due to material and fabrication process incompatibility. Currently, these devices are off-chip and they require external circuitries to interface with the ICs. This configuration significantly increases the overall size and cost of the entire electronic system. In addition, extra external connection, especially at high frequency, will potentially create negative impacts on the performance of the entire system due to signal degradation and parasitic effects. Furthermore, due to off-chip packaging nature, these devices are quite expensive, particularly for high frequency and high quality factor devices. To address these issues, researchers have been intensively studying on an alternative for type of resonator by utilizing the new emerging MEMS (Micro-electro-mechanical systems) technology. Recent progress in this field has demonstrated a MEMS resonator with resonant frequency of 2.97 GHz and quality factor (measured in vacuum) of 42900. Despite this great achievement, this prototype is still far from being fully integrated into CMOS system due to incompatibility in fabrication process and its high series motional impedance. On the other hand, fully integrated MEMS resonator had been demonstrated but at lower frequency and quality factor. We propose a design and fabrication process for a low cost, high frequency and a high quality MEMS resonator, which can be integrated into a standard CMOS IC. This device is expected to operate in hundreds of Mhz frequency range; quality factor surpasses 10000 and series motional impedance low enough that could be matching into conventional system without enormous effort. This MEMS resonator can be used in the design of many blocks in wireless and RF (Radio Frequency) systems such as low phase noise oscillator, band pass filter, power amplifier and in many sensing application.

  12. External auditory canal atresia of probable congenital origin in a dog.

    PubMed

    Schmidt, K; Piaia, T; Bertolini, G; De Lorenzi, D

    2007-04-01

    A nine-month-old Labrador retriever was referred to the Clinica Veterinaria Privata San Marco because of frequent headshaking and downward turning of the right ear. Clinical examination revealed that there was no external acoustic meatus in the right ear. Computed tomography confirmed that the vertical part of the right auditory canal ended blindly, providing a diagnosis of external auditory canal atresia. Cytological examination and culture of fluid from the canal and the bulla revealed only aseptic cerumen; for this reason, it was assumed that the dog was probably affected by a congenital developmental deformity of the external auditory canal. Reconstructive surgery was performed using a "pull-through" technique. Four months after surgery the cosmetic and functional results were satisfactory.

  13. External store effects on the stability of fighter and interceptor airplanes. [application to military aircraft mission requirements

    NASA Technical Reports Server (NTRS)

    Spearman, M. L.; Sawyer, W. C.

    1974-01-01

    Some criteria for external carriage of missiles for fighter aircraft intended for aerial combat missions and for fighter-interceptor missions are considered. The mission requirements discussed include the short-range fighter-interceptor, the short-range interceptor, the medium-range interceptor, and the long-range interceptor. Missiles types considered to be compatible with the various point mission designs include the short-range missile, the medium-range missile, and the long-range missile. From the study, it appears that point mission design aircraft can be arranged in such a way that the required external-store arrangement will not impair the stability of the aircraft. An extensive reference list of NASA external store research is included.

  14. The Biological Reference Repository (BioR): a rapid and flexible system for genomics annotation.

    PubMed

    Kocher, Jean-Pierre A; Quest, Daniel J; Duffy, Patrick; Meiners, Michael A; Moore, Raymond M; Rider, David; Hossain, Asif; Hart, Steven N; Dinu, Valentin

    2014-07-01

    The Biological Reference Repository (BioR) is a toolkit for annotating variants. BioR stores public and user-specific annotation sources in indexed JSON-encoded flat files (catalogs). The BioR toolkit provides the functionality to combine and retrieve annotation from these catalogs via the command-line interface. Several catalogs from commonly used annotation sources and instructions for creating user-specific catalogs are provided. Commands from the toolkit can be combined with other UNIX commands for advanced annotation processing. We also provide instructions for the development of custom annotation pipelines. The package is implemented in Java and makes use of external tools written in Java and Perl. The toolkit can be executed on Mac OS X 10.5 and above or any Linux distribution. The BioR application, quickstart, and user guide documents and many biological examples are available at http://bioinformaticstools.mayo.edu. © The Author 2014. Published by Oxford University Press.

  15. Buildup of spatial information over time and across eye-movements.

    PubMed

    Zimmermann, Eckart; Morrone, M Concetta; Burr, David C

    2014-12-15

    To interact rapidly and effectively with our environment, our brain needs access to a neural representation of the spatial layout of the external world. However, the construction of such a map poses major challenges, as the images on our retinae depend on where the eyes are looking, and shift each time we move our eyes, head and body to explore the world. Research from many laboratories including our own suggests that the visual system does compute spatial maps that are anchored to real-world coordinates. However, the construction of these maps takes time (up to 500ms) and also attentional resources. We discuss research investigating how retinotopic reference frames are transformed into spatiotopic reference-frames, and how this transformation takes time to complete. These results have implications for theories about visual space coordinates and particularly for the current debate about the existence of spatiotopic representations. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Role of real-space micromotion for bosonic and fermionic Floquet fractional Chern insulators

    NASA Astrophysics Data System (ADS)

    Anisimovas, Egidijus; Žlabys, Giedrius; Anderson, Brandon M.; JuzeliÅ«nas, Gediminas; Eckardt, André

    2015-06-01

    Fractional Chern insulators are the proposed phases of matter mimicking the physics of fractional quantum Hall states on a lattice without an overall magnetic field. The notion of Floquet fractional Chern insulators refers to the potential possibilities to generate the underlying topological band structure by means of Floquet engineering. In these schemes, a highly controllable and strongly interacting system is periodically driven by an external force at a frequency such that double tunneling events during one forcing period become important and contribute to shaping the required effective energy bands. We show that in the described circumstances it is necessary to take into account also third order processes combining two tunneling events with interactions. Referring to the obtained contributions as micromotion-induced interactions, we find that those interactions tend to have a negative impact on the stability of fractional Chern insulating phases and discuss implications for future experiments.

  17. Design and Analysis of an Attitude Determination and Control Subsystem (ADCS) for AFIT’s 6U Standard Bus

    DTIC Science & Technology

    2014-03-27

    Fault Detection and Isolation GUI Graphical User Interface IGRF International Geomagnetic Reference Field IMU Inertial Measurement Unit IR infrared xv...ADCS hardware components were either commercially purchased or built in-house and include an Inertial Measurement Unit ( IMU ), external magnetometer, 4...3.2.1.3 IMU . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 3.2.1.4 External Magnetometer . . . . . . . . . . . . . . . . . . 48 3.2.2

  18. A multilaboratory comparison of calibration accuracy and the performance of external references in analytical ultracentrifugation.

    PubMed

    Zhao, Huaying; Ghirlando, Rodolfo; Alfonso, Carlos; Arisaka, Fumio; Attali, Ilan; Bain, David L; Bakhtina, Marina M; Becker, Donald F; Bedwell, Gregory J; Bekdemir, Ahmet; Besong, Tabot M D; Birck, Catherine; Brautigam, Chad A; Brennerman, William; Byron, Olwyn; Bzowska, Agnieszka; Chaires, Jonathan B; Chaton, Catherine T; Cölfen, Helmut; Connaghan, Keith D; Crowley, Kimberly A; Curth, Ute; Daviter, Tina; Dean, William L; Díez, Ana I; Ebel, Christine; Eckert, Debra M; Eisele, Leslie E; Eisenstein, Edward; England, Patrick; Escalante, Carlos; Fagan, Jeffrey A; Fairman, Robert; Finn, Ron M; Fischle, Wolfgang; de la Torre, José García; Gor, Jayesh; Gustafsson, Henning; Hall, Damien; Harding, Stephen E; Cifre, José G Hernández; Herr, Andrew B; Howell, Elizabeth E; Isaac, Richard S; Jao, Shu-Chuan; Jose, Davis; Kim, Soon-Jong; Kokona, Bashkim; Kornblatt, Jack A; Kosek, Dalibor; Krayukhina, Elena; Krzizike, Daniel; Kusznir, Eric A; Kwon, Hyewon; Larson, Adam; Laue, Thomas M; Le Roy, Aline; Leech, Andrew P; Lilie, Hauke; Luger, Karolin; Luque-Ortega, Juan R; Ma, Jia; May, Carrie A; Maynard, Ernest L; Modrak-Wojcik, Anna; Mok, Yee-Foong; Mücke, Norbert; Nagel-Steger, Luitgard; Narlikar, Geeta J; Noda, Masanori; Nourse, Amanda; Obsil, Tomas; Park, Chad K; Park, Jin-Ku; Pawelek, Peter D; Perdue, Erby E; Perkins, Stephen J; Perugini, Matthew A; Peterson, Craig L; Peverelli, Martin G; Piszczek, Grzegorz; Prag, Gali; Prevelige, Peter E; Raynal, Bertrand D E; Rezabkova, Lenka; Richter, Klaus; Ringel, Alison E; Rosenberg, Rose; Rowe, Arthur J; Rufer, Arne C; Scott, David J; Seravalli, Javier G; Solovyova, Alexandra S; Song, Renjie; Staunton, David; Stoddard, Caitlin; Stott, Katherine; Strauss, Holger M; Streicher, Werner W; Sumida, John P; Swygert, Sarah G; Szczepanowski, Roman H; Tessmer, Ingrid; Toth, Ronald T; Tripathy, Ashutosh; Uchiyama, Susumu; Uebel, Stephan F W; Unzai, Satoru; Gruber, Anna Vitlin; von Hippel, Peter H; Wandrey, Christine; Wang, Szu-Huan; Weitzel, Steven E; Wielgus-Kutrowska, Beata; Wolberger, Cynthia; Wolff, Martin; Wright, Edward; Wu, Yu-Sung; Wubben, Jacinta M; Schuck, Peter

    2015-01-01

    Analytical ultracentrifugation (AUC) is a first principles based method to determine absolute sedimentation coefficients and buoyant molar masses of macromolecules and their complexes, reporting on their size and shape in free solution. The purpose of this multi-laboratory study was to establish the precision and accuracy of basic data dimensions in AUC and validate previously proposed calibration techniques. Three kits of AUC cell assemblies containing radial and temperature calibration tools and a bovine serum albumin (BSA) reference sample were shared among 67 laboratories, generating 129 comprehensive data sets. These allowed for an assessment of many parameters of instrument performance, including accuracy of the reported scan time after the start of centrifugation, the accuracy of the temperature calibration, and the accuracy of the radial magnification. The range of sedimentation coefficients obtained for BSA monomer in different instruments and using different optical systems was from 3.655 S to 4.949 S, with a mean and standard deviation of (4.304 ± 0.188) S (4.4%). After the combined application of correction factors derived from the external calibration references for elapsed time, scan velocity, temperature, and radial magnification, the range of s-values was reduced 7-fold with a mean of 4.325 S and a 6-fold reduced standard deviation of ± 0.030 S (0.7%). In addition, the large data set provided an opportunity to determine the instrument-to-instrument variation of the absolute radial positions reported in the scan files, the precision of photometric or refractometric signal magnitudes, and the precision of the calculated apparent molar mass of BSA monomer and the fraction of BSA dimers. These results highlight the necessity and effectiveness of independent calibration of basic AUC data dimensions for reliable quantitative studies.

  19. A Multilaboratory Comparison of Calibration Accuracy and the Performance of External References in Analytical Ultracentrifugation

    PubMed Central

    Zhao, Huaying; Ghirlando, Rodolfo; Alfonso, Carlos; Arisaka, Fumio; Attali, Ilan; Bain, David L.; Bakhtina, Marina M.; Becker, Donald F.; Bedwell, Gregory J.; Bekdemir, Ahmet; Besong, Tabot M. D.; Birck, Catherine; Brautigam, Chad A.; Brennerman, William; Byron, Olwyn; Bzowska, Agnieszka; Chaires, Jonathan B.; Chaton, Catherine T.; Cölfen, Helmut; Connaghan, Keith D.; Crowley, Kimberly A.; Curth, Ute; Daviter, Tina; Dean, William L.; Díez, Ana I.; Ebel, Christine; Eckert, Debra M.; Eisele, Leslie E.; Eisenstein, Edward; England, Patrick; Escalante, Carlos; Fagan, Jeffrey A.; Fairman, Robert; Finn, Ron M.; Fischle, Wolfgang; de la Torre, José García; Gor, Jayesh; Gustafsson, Henning; Hall, Damien; Harding, Stephen E.; Cifre, José G. Hernández; Herr, Andrew B.; Howell, Elizabeth E.; Isaac, Richard S.; Jao, Shu-Chuan; Jose, Davis; Kim, Soon-Jong; Kokona, Bashkim; Kornblatt, Jack A.; Kosek, Dalibor; Krayukhina, Elena; Krzizike, Daniel; Kusznir, Eric A.; Kwon, Hyewon; Larson, Adam; Laue, Thomas M.; Le Roy, Aline; Leech, Andrew P.; Lilie, Hauke; Luger, Karolin; Luque-Ortega, Juan R.; Ma, Jia; May, Carrie A.; Maynard, Ernest L.; Modrak-Wojcik, Anna; Mok, Yee-Foong; Mücke, Norbert; Nagel-Steger, Luitgard; Narlikar, Geeta J.; Noda, Masanori; Nourse, Amanda; Obsil, Tomas; Park, Chad K.; Park, Jin-Ku; Pawelek, Peter D.; Perdue, Erby E.; Perkins, Stephen J.; Perugini, Matthew A.; Peterson, Craig L.; Peverelli, Martin G.; Piszczek, Grzegorz; Prag, Gali; Prevelige, Peter E.; Raynal, Bertrand D. E.; Rezabkova, Lenka; Richter, Klaus; Ringel, Alison E.; Rosenberg, Rose; Rowe, Arthur J.; Rufer, Arne C.; Scott, David J.; Seravalli, Javier G.; Solovyova, Alexandra S.; Song, Renjie; Staunton, David; Stoddard, Caitlin; Stott, Katherine; Strauss, Holger M.; Streicher, Werner W.; Sumida, John P.; Swygert, Sarah G.; Szczepanowski, Roman H.; Tessmer, Ingrid; Toth, Ronald T.; Tripathy, Ashutosh; Uchiyama, Susumu; Uebel, Stephan F. W.; Unzai, Satoru; Gruber, Anna Vitlin; von Hippel, Peter H.; Wandrey, Christine; Wang, Szu-Huan; Weitzel, Steven E.; Wielgus-Kutrowska, Beata; Wolberger, Cynthia; Wolff, Martin; Wright, Edward; Wu, Yu-Sung; Wubben, Jacinta M.; Schuck, Peter

    2015-01-01

    Analytical ultracentrifugation (AUC) is a first principles based method to determine absolute sedimentation coefficients and buoyant molar masses of macromolecules and their complexes, reporting on their size and shape in free solution. The purpose of this multi-laboratory study was to establish the precision and accuracy of basic data dimensions in AUC and validate previously proposed calibration techniques. Three kits of AUC cell assemblies containing radial and temperature calibration tools and a bovine serum albumin (BSA) reference sample were shared among 67 laboratories, generating 129 comprehensive data sets. These allowed for an assessment of many parameters of instrument performance, including accuracy of the reported scan time after the start of centrifugation, the accuracy of the temperature calibration, and the accuracy of the radial magnification. The range of sedimentation coefficients obtained for BSA monomer in different instruments and using different optical systems was from 3.655 S to 4.949 S, with a mean and standard deviation of (4.304 ± 0.188) S (4.4%). After the combined application of correction factors derived from the external calibration references for elapsed time, scan velocity, temperature, and radial magnification, the range of s-values was reduced 7-fold with a mean of 4.325 S and a 6-fold reduced standard deviation of ± 0.030 S (0.7%). In addition, the large data set provided an opportunity to determine the instrument-to-instrument variation of the absolute radial positions reported in the scan files, the precision of photometric or refractometric signal magnitudes, and the precision of the calculated apparent molar mass of BSA monomer and the fraction of BSA dimers. These results highlight the necessity and effectiveness of independent calibration of basic AUC data dimensions for reliable quantitative studies. PMID:25997164

  20. Insulin compatibility with polymer materials used in external pump infusion systems.

    PubMed

    Melberg, S G; Havelund, S; Villumsen, J; Brange, J

    1988-04-01

    In a study designed to mimic actual user conditions for external insulin pump infusion, the insulin quality after passage through the infusion set was assessed by various analytical methods, including high performance liquid chromatography. The two infusion sets tested consisted of, firstly, a polyvinylchloride/rubber syringe and a polyvinylchloride catheter sterilized by gamma irradiation and, secondly, a polyethylene/polypropylene syringe connected to a polyethylene catheter and sterilized by ethylene oxide. The insulin solution delivered through the PVC infusion set showed a reduction of preservative to less than 30% of the initial content and increased formation of chemical transformation products of insulin varying from twice the reference level during the first day to more than three times on the third day. By contrast, the polyethylene/polypropylene infusion system showed only a minor decrease in preservative content and no increase in chemical transformation. These effects were observed irrespective of the brand of insulin and were not affected by increase of the zinc content of the insulin solution. Investigation of the influence of the sterilization methods performed on polyvinylchloride and polyethylene catheters revealed that gamma irradiated polyvinylchloride catheters were markedly harmful to the insulin solution, whereas ethylene oxide sterilization did not influence the chemical stability of insulin.

  1. Bibliography on propulsion airframe integration technologies for high-speed civil transport applications, 1980-1991

    NASA Technical Reports Server (NTRS)

    Anderson, David J.; Mizukami, Masashi

    1993-01-01

    NASA has initiated the High Speed Research (HSR) program with the goal to develop technologies for a new generation, economically viable, environmentally acceptable, supersonic transport (SST) called the High Speed Civil Transport (HSCT). A significant part of this effort is expected to be in multidisciplinary systems integration, such as in propulsion airframe integration (PAI). In order to assimilate the knowledge database on PAI for SST type aircraft, a bibliography on this subject was compiled. The bibliography with over 1200 entries, full abstracts, and indexes. Related topics are also covered, such as the following: engine inlets, engine cycles, nozzles, existing supersonic cruise aircraft, noise issues, computational fluid dynamics, aerodynamics, and external interference. All identified documents from 1980 through early 1991 are included; this covers the latter part of the NASA Supersonic Cruise Research (SCR) program and the beginnings of the HSR program. In addition, some pre-1980 documents of significant merit or reference value are also included. The references were retrieved via a computerized literature search using the NASA RECON database system.

  2. AmapSim: a structural whole-plant simulator based on botanical knowledge and designed to host external functional models.

    PubMed

    Barczi, Jean-François; Rey, Hervé; Caraglio, Yves; de Reffye, Philippe; Barthélémy, Daniel; Dong, Qiao Xue; Fourcaud, Thierry

    2008-05-01

    AmapSim is a tool that implements a structural plant growth model based on a botanical theory and simulates plant morphogenesis to produce accurate, complex and detailed plant architectures. This software is the result of more than a decade of research and development devoted to plant architecture. New advances in the software development have yielded plug-in external functions that open up the simulator to functional processes. The simulation of plant topology is based on the growth of a set of virtual buds whose activity is modelled using stochastic processes. The geometry of the resulting axes is modelled by simple descriptive functions. The potential growth of each bud is represented by means of a numerical value called physiological age, which controls the value for each parameter in the model. The set of possible values for physiological ages is called the reference axis. In order to mimic morphological and architectural metamorphosis, the value allocated for the physiological age of buds evolves along this reference axis according to an oriented finite state automaton whose occupation and transition law follows a semi-Markovian function. Simulations were performed on tomato plants to demonstrate how the AmapSim simulator can interface external modules, e.g. a GREENLAB growth model and a radiosity model. The algorithmic ability provided by AmapSim, e.g. the reference axis, enables unified control to be exercised over plant development parameter values, depending on the biological process target: how to affect the local pertinent process, i.e. the pertinent parameter(s), while keeping the rest unchanged. This opening up to external functions also offers a broadened field of applications and thus allows feedback between plant growth and the physical environment.

  3. AmapSim: A Structural Whole-plant Simulator Based on Botanical Knowledge and Designed to Host External Functional Models

    PubMed Central

    Barczi, Jean-François; Rey, Hervé; Caraglio, Yves; de Reffye, Philippe; Barthélémy, Daniel; Dong, Qiao Xue; Fourcaud, Thierry

    2008-01-01

    Background and Aims AmapSim is a tool that implements a structural plant growth model based on a botanical theory and simulates plant morphogenesis to produce accurate, complex and detailed plant architectures. This software is the result of more than a decade of research and development devoted to plant architecture. New advances in the software development have yielded plug-in external functions that open up the simulator to functional processes. Methods The simulation of plant topology is based on the growth of a set of virtual buds whose activity is modelled using stochastic processes. The geometry of the resulting axes is modelled by simple descriptive functions. The potential growth of each bud is represented by means of a numerical value called physiological age, which controls the value for each parameter in the model. The set of possible values for physiological ages is called the reference axis. In order to mimic morphological and architectural metamorphosis, the value allocated for the physiological age of buds evolves along this reference axis according to an oriented finite state automaton whose occupation and transition law follows a semi-Markovian function. Key Results Simulations were performed on tomato plants to demostrate how the AmapSim simulator can interface external modules, e.g. a GREENLAB growth model and a radiosity model. Conclusions The algorithmic ability provided by AmapSim, e.g. the reference axis, enables unified control to be exercised over plant development parameter values, depending on the biological process target: how to affect the local pertinent process, i.e. the pertinent parameter(s), while keeping the rest unchanged. This opening up to external functions also offers a broadened field of applications and thus allows feedback between plant growth and the physical environment. PMID:17766310

  4. Characteristics of internalizing and externalizing disorders in medication-naive, clinically referred children with attention deficit hyperactivity disorder, combined type and dysthymic disorder.

    PubMed

    Sanders, Michelle; Arduca, Yolanda; Karamitsios, Mary; Boots, Marilyn; Vance, Alasdair

    2005-05-01

    Internalizing and externalizing disorders are frequently comorbid with attention deficit hyperactivity disorder, combined type (ADHD-CT) and dysthymic disorder (DD) in referred primary school-age children, yet there has been relatively little systematic research of the nature of these comorbid disorders. We describe the characteristics of parent- and child-reported internalizing and externalizing disorders in primary school-age children with ADHD-CT and DD. A cross-sectional study of 45 clinically referred medication naive children with ADHD-CT and DD, examining parent and child reports of internalizing and externalizing disorders, defined categorically and dimensionally. Generalized anxiety disorder and separation anxiety disorder were increased in the DD groups, whether ADHD-CT was present or not. Major depressive disorder was increased in the ADHD-CT and DD group compared to the ADHD-CT alone and the DD alone groups. Conduct disorder was increased in the ADHD-CT alone group compared to the DD with and without ADHD-CT groups. Verbal and fullscale IQ were increased in the DD groups, whether ADHD-CT was present or not, compared to the ADHD-CT alone group. There is emerging evidence that DD and anxiety may represent a different phenotypic expression of a common underlying aetiological process, while the co-occurrence of ADHD-CT and anxiety disorders remains unclear. Only the ADHD-CT and DD group is significantly associated with major depressive disorder, which suggests an additive effect. In contrast, conduct disorder and decreased verbal and fullscale IQ are only associated with the ADHD-CT group, which may suggest a protective effect of DD when comorbid with ADHD-CT. From a research perspective, it is important to confirm these found associations in larger samples derived from epidemiological populations.

  5. Effect of Laterally Wedged Insoles on the External Knee Adduction Moment across Different Reference Frames.

    PubMed

    Yamaguchi, Satoshi; Kitamura, Masako; Ushikubo, Tomohiro; Murata, Atsushi; Akagi, Ryuichiro; Sasho, Takahisa

    2015-01-01

    Biomechanical effects of laterally wedged insoles are assessed by reduction in the knee adduction moment. However, the degree of reduction may vary depending on the reference frame with which it is calculated. The purpose of this study was to clarify the effect of reference frame on the reduction in the knee adduction moment by laterally wedged insoles. Twenty-nine healthy participants performed gait trials with a laterally wedged insole and with a flat insole as a control. The knee adduction moment, including the first and second peaks and the angular impulse, were calculated using four different reference frames: the femoral frame, tibial frame, laboratory frame and the Joint Coordinate System. There were significant effects of reference frame on the knee adduction moment first and second peaks (P < 0.001 for both variables), while the effect was not significant for the angular impulse (P = 0.84). No significant interaction between the gait condition and reference frame was found in either of the knee adduction moment variables (P = 0.99 for all variables), indicating that the effects of laterally wedged insole on the knee adduction moments were similar across the four reference frames. On the other hand, the average percent changes ranged from 9% to 16% for the first peak, from 16% to 18% for the second peak and from 17% to 21% for the angular impulse when using the different reference frames. The effects of laterally wedged insole on the reduction in the knee adduction moment were similar across the reference frames. On the other hand, Researchers need to recognize that when the percent change was used as the parameter of the efficacy of laterally wedged insole, the choice of reference frame may influence the interpretation of how laterally wedged insoles affect the knee adduction moment.

  6. Lunar Navigation Determination System - LaNDS

    NASA Technical Reports Server (NTRS)

    Quinn, David; Talabac, Stephen

    2012-01-01

    A portable comprehensive navigational system has been developed that both robotic and human explorers can use to determine their location, attitude, and heading anywhere on the lunar surface independent of external infrastructure (needs no Lunar satellite network, line of sight to the Sun or Earth, etc.). The system combines robust processing power with an extensive topographical database to create a real-time atlas (GIS Geospatial Information System) that is able to autonomously control and monitor both single unmanned rovers and fleets of rovers, as well as science payload stations. The system includes provisions for teleoperation and tele-presence. The system accepts (but does not require) inputs from a wide range of sensors. A means was needed to establish a location when the search is taken deep in a crater (looking for water ice) and out of view of Earth or any other references. A star camera can be employed to determine the user's attitude in menial space and stellar map in body space. A local nadir reference (e.g., an accelerometer that orients the nadir vector in body space) can be used in conjunction with a digital ephemeris and gravity model of the Moon to isolate the latitude, longitude, and azimuth of the user on the surface. That information can be used in conjunction with a Lunar GIS and advanced navigation planning algorithms to aid astronauts (or other assets) to navigate on the Lunar surface.

  7. Analysis of a flare-director concept for an externally blown flap STOL aircraft

    NASA Technical Reports Server (NTRS)

    Middleton, D. B.

    1974-01-01

    A flare-director concept involving a thrust-required flare-guidance equation was developed and tested on a moving-base simulator. The equation gives a signal to command thrust as a linear function of the errors between the variables thrust, altitude, and altitude rate and corresponding values on a desired reference flare trajectory. During the simulator landing tests this signal drove either the horizontal command bar of the aircraft's flight director or a thrust-command dot on a head-up virtual-image display of a flare director. It was also used as the input to a simple autoflare system. An externally blown flap STOL (short take-off and landing) aircraft (with considerable stability and control augmentation) was modeled for the landing tests. The pilots considered the flare director a valuable guide for executing a proper flare-thrust program under instrument-landing conditions, but were reluctant to make any use of the head-up display when they were performing the landings visually.

  8. Linear network representation of multistate models of transport.

    PubMed Central

    Sandblom, J; Ring, A; Eisenman, G

    1982-01-01

    By introducing external driving forces in rate-theory models of transport we show how the Eyring rate equations can be transformed into Ohm's law with potentials that obey Kirchhoff's second law. From such a formalism the state diagram of a multioccupancy multicomponent system can be directly converted into linear network with resistors connecting nodal (branch) points and with capacitances connecting each nodal point with a reference point. The external forces appear as emf or current generators in the network. This theory allows the algebraic methods of linear network theory to be used in solving the flux equations for multistate models and is particularly useful for making proper simplifying approximation in models of complex membrane structure. Some general properties of linear network representation are also deduced. It is shown, for instance, that Maxwell's reciprocity relationships of linear networks lead directly to Onsager's relationships in the near equilibrium region. Finally, as an example of the procedure, the equivalent circuit method is used to solve the equations for a few transport models. PMID:7093425

  9. Atronomical CCD observations of the main Saturn's satellites at Pulkovo Observatory in 2004-2007

    NASA Astrophysics Data System (ADS)

    Khrutskaya, E. V.; Kiseleva, T. P.; Izmailov, I. S.; Khovrichev, M. Yu.; Berezhnoy, A. A.

    2009-08-01

    The results of astrometric observations of Saturn’s satellites (S1-S8) obtained using a 26-inch refractor and a normal astrograph at Pulkovo Observatory in 2004-2007 are given. High-accuracy equatorial coordinates of Saturn’s satellites in the system of the UCAC2 reference catalog and the relative “satellite-satellite” positions suitable for specifying their motion theories are obtained. The observations are compared with the DE405 + TASS1.7 and INPOP06 + TASS1.7 theories of motion. The root-mean-square errors of the obtained satellite positions lie within the range of 10-50 mas, as far as the intrinsic convergence is concerned, and 20-70 mas, as far as the extrinsic one is concerned. The observation results are included into the astrometrical database of the Pulkovo Observatory ( www.puldb.ru ).

  10. Cognitive vulnerabilities and depression versus other psychopathology symptoms and diagnoses in early adolescence.

    PubMed

    Alloy, Lauren B; Black, Shimrit K; Young, Mathew E; Goldstein, Kim E; Shapero, Benjamin G; Stange, Jonathan P; Boccia, Angelo S; Matt, Lindsey M; Boland, Elaine M; Moore, Lauren C; Abramson, Lyn Y

    2012-01-01

    We examined the concurrent associations between multiple cognitive vulnerabilities to depression featured in hopelessness theory, Beck's theory, and response styles theory and depressive symptoms and diagnoses in a sample of early adolescents. We also examined the specificity of these cognitive vulnerabilities to depression versus anxiety and externalizing psychopathology, controlling for co-occurring symptoms and diagnoses. Male and female, Caucasian and African American, 12- to 13-year-old adolescents were assessed in a cross-sectional design. Cognitive vulnerabilities of hopelessness, inferential style, rumination, and self-referent information processing were assessed with self-reports and behavioral tasks. Symptoms and diagnoses of depressive, anxiety, and externalizing disorders were assessed with self-report questionnaires and diagnostic interviews. Hopelessness exhibited the greatest specificity to depressive symptoms and diagnoses, whereas negative inferential styles, rumination, and negative self-referent information processing were associated with both depressive and anxiety symptoms and diagnoses and, in some cases, with externalizing disorders. Consistent with cognitive theories of depression, hopelessness, negative inferential styles, rumination, and negative self-referent information processing were associated with depressive symptoms and diagnoses. However, with the exception of hopelessness, most of the remaining cognitive vulnerabilities were not specific to depression. With further maturation of our sample, these cognitive vulnerabilities may become more specific to depression as cognitive styles further develop and consolidate, the rates of depression increase, and individuals' presentations of psychopathology become more differentiated.

  11. Cognitive Vulnerabilities and Depression versus Other Psychopathology Symptoms and Diagnoses in Early Adolescence

    PubMed Central

    Alloy, Lauren B.; Black, Shimrit K.; Young, Mathew E.; Goldstein, Kim E.; Shapero, Benjamin G.; Stange, Jonathan P.; Boccia, Angelo S.; Matt, Lindsey M.; Boland, Elaine M.; Moore, Lauren C.; Abramson, Lyn Y.

    2012-01-01

    Objective We examined the concurrent associations between multiple cognitive vulnerabilities to depression featured in Hopelessness Theory, Beck’s Theory, and Response Styles Theory and depressive symptoms and diagnoses in a sample of early adolescents. We also examined the specificity of these cognitive vulnerabilities to depression versus anxiety and externalizing psychopathology, controlling for co-occurring symptoms and diagnoses. Method Male and female, Caucasian and African-American, 12–13 year old adolescents were assessed in a cross-sectional design. Cognitive vulnerabilities of hopelessness, inferential style, rumination, and self-referent information processing were assessed with self-reports and behavioral tasks. Symptoms and diagnoses of depressive, anxiety, and externalizing disorders were assessed with self-report questionnaires and diagnostic interviews. Results Hopelessness exhibited the greatest specificity to depressive symptoms and diagnoses, whereas negative inferential styles, rumination, and negative self-referent information processing were associated with both depressive and anxiety symptoms and diagnoses and, in some cases, with externalizing disorders. Conclusions Consistent with cognitive theories of depression, hopelessness, negative inferential styles, rumination, and negative self-referent information processing were associated with depressive symptoms and diagnoses. However, with the exception of hopelessness, most of the remaining cognitive vulnerabilities were not specific to depression. With further maturation of our sample, these cognitive vulnerabilities may become more specific to depression as cognitive styles further develop and consolidate, the rates of depression increase, and individuals’ presentations of psychopathology become more differentiated. PMID:22853629

  12. Ecological comparisons of Lake Erie tributaries with elevated incidence of fish tumors

    USGS Publications Warehouse

    Smith, Stephen B.; Blouin, Marc A.; Mac, Michael J.

    1994-01-01

    Ecological comparisons were made between two Lake Erie tributaries (Black and Cuyahoga rivers) with contaminated sediments and elevated rates of tumors in fish populations and a third, relatively unpolluted, reference tributary, the Huron River. Fish populations, benthic invertebrates, and sediments were evaluated in all three Ohio rivers. Community structure analyses indicated similar total densities but lower species diversity for fish and benthic invertebrates in the contaminated rivers when compared with the reference river. Growth rates in fish from the contaminated areas were either similar to or higher than those offish from the reference site. Brown bullhead (Ameiurus nebulosus) from the two contaminated tributaries exhibited 51% (Black River) and 45% (Cuyahoga River) incidence of liver lesions (neoplastic and preneoplastic) as compared with a 4% incidence of liver lesions in brown bullhead from the reference river (Huron River). Incidence of external abnormalities on brown bullhead was 54% (Black River) and 73% (Cuyahoga River) as compared with a 14% incidence on fish from the Huron River. On a regional basis, incidence of external abnormalities on particular benthic fish species may be an effective method to quickly indicate areas for more intensive contaminant studies.

  13. Landauer-Büttiker Approach to Strongly Coupled Quantum Thermodynamics: Inside-Outside Duality of Entropy Evolution

    NASA Astrophysics Data System (ADS)

    Bruch, Anton; Lewenkopf, Caio; von Oppen, Felix

    2018-03-01

    We develop a Landauer-Büttiker theory of entropy evolution in time-dependent, strongly coupled electron systems. The formalism naturally avoids the problem of the system-bath distinction by defining the entropy current in the attached leads. This current can then be used to infer changes of the entropy of the system which we refer to as the inside-outside duality. We carry out this program in an adiabatic expansion up to first order beyond the quasistatic limit. When combined with particle and energy currents, as well as the work required to change an external potential, our formalism provides a full thermodynamic description, applicable to arbitrary noninteracting electron systems in contact with reservoirs. This provides a clear understanding of the relation between heat and entropy currents generated by time-dependent potentials and their connection to the occurring dissipation.

  14. An external dosimetry audit programme to credential static and rotational IMRT delivery for clinical trials quality assurance.

    PubMed

    Eaton, David J; Tyler, Justine; Backshall, Alex; Bernstein, David; Carver, Antony; Gasnier, Anne; Henderson, Julia; Lee, Jonathan; Patel, Rushil; Tsang, Yatman; Yang, Huiqi; Zotova, Rada; Wells, Emma

    2017-03-01

    External dosimetry audits give confidence in the safe and accurate delivery of radiotherapy. The RTTQA group have performed an on-site audit programme for trial recruiting centres, who have recently implemented static or rotational IMRT, and those with major changes to planning or delivery systems. Measurements of reference beam output were performed by the host centre, and by the auditor using independent equipment. Verification of clinical plans was performed using the ArcCheck helical diode array. A total of 54 measurement sessions were performed between May 2014 and June 2016 at 28 UK institutions, reflecting the different combinations of planning and delivery systems used at each institution. Average ratio of measured output between auditor and host was 1.002±0.006. Average point dose agreement for clinical plans was -0.3±1.8%. Average (and 95% lower confidence intervals) of gamma pass rates at 2%/2mm, 3%/2mm and 3%/3mm respectively were: 92% (80%), 96% (90%) and 98% (94%). Moderately significant differences were seen between fixed gantry angle and rotational IMRT, and between combination of planning systems and linac manufacturer, but not between anatomical treatment site or beam energy. An external audit programme has been implemented for universal and efficient credentialing of IMRT treatments in clinical trials. Good agreement was found between measured and expected doses, with few outliers, leading to a simple table of optimal and mandatory tolerances for approval of dosimetry audit results. Feedback was given to some centres leading to improved clinical practice. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  15. DPOD2014: a new DORIS extension of ITRF2014 for Precise Orbit Determination

    NASA Astrophysics Data System (ADS)

    Moreaux, G.; Willis, P.; Lemoine, F. G.; Zelensky, N. P.

    2016-12-01

    As one of the tracking systems used to determine orbits of the altimeter mission satellites (such as TOPEX/Poseidon, Envisat, Jason-1/2/3 & Cryosat-2), the position of the DORIS tracking stations provides a fundamental reference for the estimation of the precise orbits and so, by extension is fundamental for the quality of the altimeter data and derived products. Therefore, the time evolution of the position of both the existing and the newest DORIS stations must be precisely modeled and regularly updated. To satisfy operational requirements for precise orbit determination and routine delivery of geodetic products, the International DORIS Service maintains the so-called DPOD solutions, which can be seen as extensions of the latest available ITRF solution from the International Earth Rotation and Reference Systems Service (IERS). In mid-2016, the IDS agreed to change the processing strategy of the DPOD solution. The new solution from the IDS Combination Center (CC) consists of a DORIS cumulative position and velocity solution using the latest IDS combined weekly solutions. The first objective of this study is to describe the new DPOD elaboration scheme and to show the IDS CC internal validation steps. The second purpose is to present the external validation process made by an external team before the new DPOD is made available to all the users. The elaboration and validation procedures will be illustrated by the presentation of first version of the DPOD2014 (ITRF2014 DORIS extension) and focus will be given on the update of the position and velocity of two DORIS sites: Everest (after Gorkha earthquake M7.8 in April 2015) and Thule (Greenland).

  16. Implementation of quality management systems and progress towards accreditation of National Tuberculosis Reference Laboratories in Africa

    PubMed Central

    de Dieu Iragena, Jean; Kao, Kekeletso; Erni, Donatelle; Mekonen, Teferi

    2017-01-01

    Background Laboratory services are essential at all stages of the tuberculosis care cascade, from diagnosis and drug resistance testing to monitoring response to treatment. Enabling access to quality services is a challenge in low-resource settings. Implementation of a strong quality management system (QMS) and laboratory accreditation are key to improving patient care. Objectives The study objective was to determine the status of QMS implementation and progress towards accreditation of National Tuberculosis Reference Laboratories (NTRLs) in the African Region. Method An online questionnaire was administered to NTRL managers in 47 World Health Organization Regional Office for Africa member states in the region, between February and April 2015, regarding the knowledge of QMS tools and progress toward implementation to inform strategies for tuberculosis diagnostic services strengthening in the region. Results A total of 21 laboratories (43.0%) had received SLMTA/TB-SLMTA training, of which 10 had also used the Global Laboratory Initiative accreditation tool. However, only 36.7% of NTRLs had received a laboratory audit, a first step in quality improvement. Most NTRLs participated in acid-fast bacilli microscopy external quality assurance (95.8%), although external quality assurance for other techniques was lower (60.4% for first-line drug susceptibility testing, 25.0% for second-line drug susceptibility testing, and 22.9% for molecular testing). Barriers to accreditation included lack of training and accreditation programmes. Only 28.6% of NTRLs had developed strategic plans and budgets which included accreditation. Conclusion Good foundations are in place on the continent from which to scale up accreditation efforts. Laboratory audits should be conducted as a first step in developing quality improvement action plans. Political commitment and strong leadership are needed to drive accreditation efforts; advocacy will require clear evidence of patient impact and cost-benefit. PMID:28879161

  17. External Nasal Neuralgia: A Neuropathic Pain Within the Territory of the External Nasal Nerve.

    PubMed

    García-Moreno, Héctor; Aledo-Serrano, Ángel; Gimeno-Hernández, Jesús; Cuadrado, María-Luz

    2015-10-01

    Nasal pain is a challenging diagnosis and very little has been reported in the neurological literature. The nose is a sophisticated structure regarding its innervation, which is supplied by the first and second divisions of the trigeminal nerve. Painful cranial neuropathies are an important group in the differential diagnosis, although they have been described only scarcely. Here, we report a case that can conform a non-traumatic external nasal nerve neuralgia. A 76-year-old woman was referred to our office due to pain in her left nose. She was suffering from daily excruciating attacks, which were strictly limited to the territory supplied by her left external nasal nerve (left ala nasi and apex nasi). She denied previous traumatisms and the ancillary tests did not yield any underlying pathology. An anesthetic blockade of her left external nasal nerve achieved a marked reduction of the number of episodes as well as their intensity. External nasal neuralgia seems a specific neuralgia causing nasal pain. Anesthetic blockades of the external nasal nerve may be a valid treatment for this condition. © 2015 American Headache Society.

  18. Tools reference manual for a Requirements Specification Language (RSL), version 2.0

    NASA Technical Reports Server (NTRS)

    Fisher, Gene L.; Cohen, Gerald C.

    1993-01-01

    This report describes a general-purpose Requirements Specification Language, RSL. The purpose of RSL is to specify precisely the external structure of a mechanized system and to define requirements that the system must meet. A system can be comprised of a mixture of hardware, software, and human processing elements. RSL is a hybrid of features found in several popular requirements specification languages, such as SADT (Structured Analysis and Design Technique), PSL (Problem Statement Language), and RMF (Requirements Modeling Framework). While languages such as these have useful features for structuring a specification, they generally lack formality. To overcome the deficiencies of informal requirements languages, RSL has constructs for formal mathematical specification. These constructs are similar to those found in formal specification languages such as EHDM (Enhanced Hierarchical Development Methodology), Larch, and OBJ3.

  19. Global harmonization of food safety regulations: perspectives from Japan after the Fukushima nuclear accident.

    PubMed

    Yoshida, Mitsuru

    2014-08-01

    Japanese food self-sufficiency was only 39% on the basis of kcal in 2012, so Japan relies heavily on imported food. Hence the necessity of having international rules on the regulation of food contaminants is important especially for countries like Japan that depend on food imports. A One-Stop-Testing system is desired, in which the test result obtained from a single testing laboratory is accepted as valid worldwide. To establish this system, laboratory accreditation under international standards is a necessary step. Furthermore, the importance of supply of reference materials for internal quality control and proficiency testing for external quality control of each laboratory's analytical system is reviewed in connection with the experience of radioactive nuclide contamination resulting from the Fukushima nuclear power plant accident in March 2011. © 2013 Society of Chemical Industry.

  20. IRIS Toxicological Review of Vanadium Pentoxide ...

    EPA Pesticide Factsheets

    On September 30, 2011, the draft Toxicological Review of Vanadium Pentoxide and the charge to external peer reviewers were released for external peer review and public comment. The Toxicological Review and charge were reviewed internally by EPA and by other federal agencies and White House Offices before public release. In the new IRIS process (May 2009), introduced by the EPA Administrator, all written comments on IRIS assessments submitted by other federal agencies and White House Offices will be made publicly available. Accordingly, interagency comments and the interagency science consultation draft of the IRIS Toxicological Review of Vanadium Pentoxide and the charge to external peer reviewers are posted on this site. EPA is reassessing its IRIS toxicological review of vanadium pentoxide (CASRN 1314-62-1). This vanadium pentoxide reassessment consists of an oral reference dose (RfD), an inhalation reference concentration (RfC), an inhalation unit risk (IUR) and a cancer weight of evidence descriptor. This is the first assessment developing an RfC or IUR for this compound. This assessment is intended to provide human health data to support agency regulatory decisions.

  1. Direct lead isotope analysis in Hg-rich sulfides by LA-MC-ICP-MS with a gas exchange device and matrix-matched calibration.

    PubMed

    Zhang, Wen; Hu, Zhaochu; Günther, Detlef; Liu, Yongsheng; Ling, Wenli; Zong, Keqing; Chen, Haihong; Gao, Shan

    2016-12-15

    In situ Pb isotope data of sulfide samples measured by LA-MC-ICP-MS provide valuable geochemical information for studies of the origin and evolution of ore deposits. However, the severe isobaric interference of 204 Hg on 204 Pb and the lack of matrix-matched sulfide reference materials limit the precision of Pb isotopic analyses for Hg-rich sulfides. In this study, we observe that Hg forms vapor and can be completely removed from sample aerosol particles produced by laser ablation using a gas exchange device. Additionally, this device does not influence the signal intensities of Pb isotopes. The within-run precision, the external reproducibility and the analytical accuracy are significantly improved for the Hg-rich sulfide samples using this mercury-vapor-removing device. Matrix effects are observed when using silicate glass reference materials as the external standards to assess the relationship of mass fractionation factors between Tl and Pb in sulfide samples, resulting in a maximum deviation of ∼0.20% for 20x Pb/ 204 Pb. Matrix-matched reference materials are therefore required for the highly precise and accurate Pb isotope analyses of sulfide samples. We investigated two sulfide samples, MASS-1 (the Unites States Geological Survey reference materials) and Sph-HYLM (a natural sphalerite), as potential candidates. Repeated analyses of the two proposed sulfide reference materials by LA-MC-ICP-MS yield good external reproducibility of <0.04% (RSD, k = 2) for 20x Pb/ 206 Pb and <0.06% (RSD, k = 2) for 20x Pb/ 204 Pb with the exception of 20x Pb/ 204 Pb in MASS-1, which provided an external reproducibility of 0.24% (RSD, k = 2). Because the concentration of Pb in MASS-1 (76 μg g -1 ) is ∼5.2 times lower than that in Sph-HYLM (394 ± 264 μg g -1 ). The in situ analytical results of MASS-1 and Sph-HYLM are consistent with the values obtained by solution MC-ICP-MS, demonstrating the reliability and robustness of our analytical protocol. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Lower extremity control during turns initiated with and without hip external rotation.

    PubMed

    Zaferiou, Antonia M; Flashner, Henryk; Wilcox, Rand R; McNitt-Gray, Jill L

    2017-02-08

    The pirouette turn is often initiated in neutral and externally rotated hip positions by dancers. This provides an opportunity to investigate how dancers satisfy the same mechanical objectives at the whole-body level when using different leg kinematics. The purpose of this study was to compare lower extremity control strategies during the turn initiation phase of pirouettes performed with and without hip external rotation. Skilled dancers (n=5) performed pirouette turns with and without hip external rotation. Joint kinetics during turn initiation were determined for both legs using ground reaction forces (GRFs) and segment kinematics. Hip muscle activations were monitored using electromyography. Using probability-based statistical methods, variables were compared across turn conditions as a group and within-dancer. Despite differences in GRFs and impulse generation between turn conditions, at least 90% of each GRF was aligned with the respective leg plane. A majority of the net joint moments at the ankle, knee, and hip acted about an axis perpendicular to the leg plane. However, differences in shank alignment relative to the leg plane affected the distribution of the knee net joint moment when represented with respect to the shank versus the thigh. During the initiation of both turns, most participants used ankle plantar flexor moments, knee extensor moments, flexor and abductor moments at the push leg׳s hip, and extensor and abductor moments at the turn leg׳s hip. Representation of joint kinetics using multiple reference systems assisted in understanding control priorities. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. 75 FR 8999 - Agency Information Collection Activities: Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-26

    .... Methodological findings may be presented externally in technical papers at conferences, published in the... represent several methodological improvement projects. \\2\\ This number refers to the science, engineering...

  4. FPGA-Based Networked Phasemeter for a Heterodyne Interferometer

    NASA Technical Reports Server (NTRS)

    Rao, Shanti

    2009-01-01

    A document discusses a component of a laser metrology system designed to measure displacements along the line of sight with precision on the order of a tenth the diameter of an atom. This component, the phasemeter, measures the relative phase of two electrical signals and transfers that information to a computer. Because the metrology system measures the differences between two optical paths, the phasemeter has two inputs, called measure and reference. The reference signal is nominally a perfect square wave with a 50- percent duty cycle (though only rising edges are used). As the metrology system detects motion, the difference between the reference and measure signal phases is proportional to the displacement of the motion. The phasemeter, therefore, counts the elapsed time between rising edges in the two signals, and converts the time into an estimate of phase delay. The hardware consists of a circuit board that plugs into a COTS (commercial, off-the- shelf) Spartan-III FPGA (field-programmable gate array) evaluation board. It has two BNC inputs, (reference and measure), a CMOS logic chip to buffer the inputs, and an Ethernet jack for transmitting reduced-data to a PC. Two extra BNC connectors can be attached for future expandability, such as external synchronization. Each phasemeter handles one metrology channel. A bank of six phasemeters (and two zero-crossing detector cards) with an Ethernet switch can monitor the rigid body motion of an object. This device is smaller and cheaper than existing zero-crossing phasemeters. Also, because it uses Ethernet for communication with a computer, instead of a VME bridge, it is much easier to use. The phasemeter is a key part of the Precision Deployable Apertures and Structures strategic R&D effort to design large, deployable, segmented space telescopes.

  5. Design and implementation of an external quality assessment program for HIV viral load measurements using dried blood spots.

    PubMed

    Prach, Lisa M; Puren, Adrian; Lippman, Sheri A; Carmona, Sergio; Stephenson, Sophie; Cutler, Ewalde; Barnhart, Scott; Liegler, Teri

    2015-03-01

    An external quality assurance program was developed for HIV-1 RNA viral load measurements taken from dried blood spots using a reference panel and field-collected specimens. The program demonstrated that accurate and reproducible quantitation can be obtained from field-collected specimens. Residual proviral DNA may confound interpretation in virologically suppressed subjects. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  6. Optimal Linear Responses for Markov Chains and Stochastically Perturbed Dynamical Systems

    NASA Astrophysics Data System (ADS)

    Antown, Fadi; Dragičević, Davor; Froyland, Gary

    2018-03-01

    The linear response of a dynamical system refers to changes to properties of the system when small external perturbations are applied. We consider the little-studied question of selecting an optimal perturbation so as to (i) maximise the linear response of the equilibrium distribution of the system, (ii) maximise the linear response of the expectation of a specified observable, and (iii) maximise the linear response of the rate of convergence of the system to the equilibrium distribution. We also consider the inhomogeneous, sequential, or time-dependent situation where the governing dynamics is not stationary and one wishes to select a sequence of small perturbations so as to maximise the overall linear response at some terminal time. We develop the theory for finite-state Markov chains, provide explicit solutions for some illustrative examples, and numerically apply our theory to stochastically perturbed dynamical systems, where the Markov chain is replaced by a matrix representation of an approximate annealed transfer operator for the random dynamical system.

  7. Generating precise and homogeneous orbits for Jason-1 and Jason-2

    NASA Astrophysics Data System (ADS)

    Flohrer, Claudia; Otten, Michiel; Springer, Tim; Dow, John M.

    Driven by the GMES (Global Monitoring for Environment and Security) and GGOS (Global Geodetic Observing System) initiatives the user community has a strong demand for high-quality altimetry products. In order to derive such high-quality altimetry products, precise orbits for the altimetry satellites are needed. Satellite altimetry missions meanwhile span over three decades, in which our understanding of the Earth has increased significantly. As also the models used for precise orbit determination (POD) have improved, the satellite orbits of the altimetry satellites are not available in an uniform reference system. Homogeneously determined orbits referring to the same global reference system are, however, needed to improve our understanding of the Earth system. With the launch of the TOPEX/Poseidon (T/P) mission in 1992 a still ongoing time series of high-altimetry measurements of ocean topography started. In 2001 the altimetry mission Jason-1 took over and in 2009 the follow-on program Jason-2/OSTM started. All three satellites follow the same ground-track by flying in the same orbit, thus ensuring a continuous time-series of centimetre-level ocean topography observations. Therefore a reprocessing of the orbit determination for these altimetry satellites would be highly beneficial for altimetry applications. The Navigation Support Office at ESA/ESOC has enhanced the GNSS processing capabilities of its NAPEOS software. Thus it is now in the unique position to do orbit determination by combining different types of data, and by using one single software system for different satellite types, including the most recent improvements in orbit and observation modelling and IERS conventions. Our presentation focuses on the re-processing efforts carried out by ESA/ESOC for the gener-ation of precise and homogeneous orbits referring to the same reference frame for the altimetry satellites Jason-1 and Jason-2. At the same time ESOC carried out a re-processing of the com-bined GPS/GLONASS IGS solution from 2002-2009 for the generation of 30 second satellite clocks, which enabled us to use 30 second-sampled GPS observations in our POD process. Data of all three tracking instruments on-board the satellites, i.e. GPS, DORIS, and SLR measure-ments, were used in a combined data analysis. About 8 years of Jason-1 data and about 2 years of Jason-2 data were processed. We present the orbit determination results, focusing on the benefits when adding the 30 second-sampled GPS data (used together with DORIS and SLR measurements) to the solution. We evaluate the orbit accuracy by analysing post-fit residuals, orbit overlap errors, and orbit differences between our orbits and external orbits generated by other analysis centres. The consistency between our solutions and external orbits is below the 1 cm level in the radial direction, the most crucial component for altimetry height measurements. In the cross-track component we observe a clear improvement when adding GPS data to the POD process. The use of GPS data also seems to improve the DORIS data processing, as the DORIS post-fit residuals clearly benefit.

  8. Comparison of childhood thyroid cancer prevalence among 3 areas based on external radiation dose after the Fukushima Daiichi nuclear power plant accident

    PubMed Central

    Ohira, Tetsuya; Takahashi, Hideto; Yasumura, Seiji; Ohtsuru, Akira; Midorikawa, Sanae; Suzuki, Satoru; Fukushima, Toshihiko; Shimura, Hiroki; Ishikawa, Tetsuo; Sakai, Akira; Yamashita, Shunichi; Tanigawa, Koichi; Ohto, Hitoshi; Abe, Masafumi; Suzuki, Shinichi

    2016-01-01

    Abstract The 2011 Great East Japan Earthquake led to a subsequent nuclear accident at the Fukushima Daiichi Nuclear Power Plant. In its wake, we sought to examine the association between external radiation dose and thyroid cancer in Fukushima Prefecture. We applied a cross-sectional study design with 300,476 participants aged 18 years and younger who underwent thyroid examinations between October 2011 and June 2015. Areas within Fukushima Prefecture were divided into three groups based on individual external doses (≥1% of 5 mSv, <99% of 1 mSv/y, and the other). The odds ratios (ORs) and 95% confidence intervals of thyroid cancer for all areas, with the lowest dose area as reference, were calculated using logistic regression models adjusted for age and sex. Furthermore, the ORs of thyroid cancer for individual external doses of 1 mSv or more and 2 mSv or more, with the external dose less than 1 mSv as reference, were calculated. Prevalence of thyroid cancer for the location groups were 48/100,000 for the highest dose area, 36/100,000 for the middle dose area, and 41/100,000 for the lowest dose area. Compared with the lowest dose area, age-, and sex-adjusted ORs (95% confidence intervals) for the highest-dose and middle-dose areas were 1.49 (0.36–6.23) and 1.00 (0.67–1.50), respectively. The duration between accident and thyroid examination was not associated with thyroid cancer prevalence. There were no significant associations between individual external doses and prevalence of thyroid cancer. External radiation dose was not associated with thyroid cancer prevalence among Fukushima children within the first 4 years after the nuclear accident. PMID:27583855

  9. Comparison of childhood thyroid cancer prevalence among 3 areas based on external radiation dose after the Fukushima Daiichi nuclear power plant accident: The Fukushima health management survey.

    PubMed

    Ohira, Tetsuya; Takahashi, Hideto; Yasumura, Seiji; Ohtsuru, Akira; Midorikawa, Sanae; Suzuki, Satoru; Fukushima, Toshihiko; Shimura, Hiroki; Ishikawa, Tetsuo; Sakai, Akira; Yamashita, Shunichi; Tanigawa, Koichi; Ohto, Hitoshi; Abe, Masafumi; Suzuki, Shinichi

    2016-08-01

    The 2011 Great East Japan Earthquake led to a subsequent nuclear accident at the Fukushima Daiichi Nuclear Power Plant. In its wake, we sought to examine the association between external radiation dose and thyroid cancer in Fukushima Prefecture. We applied a cross-sectional study design with 300,476 participants aged 18 years and younger who underwent thyroid examinations between October 2011 and June 2015. Areas within Fukushima Prefecture were divided into three groups based on individual external doses (≥1% of 5 mSv, <99% of 1 mSv/y, and the other). The odds ratios (ORs) and 95% confidence intervals of thyroid cancer for all areas, with the lowest dose area as reference, were calculated using logistic regression models adjusted for age and sex. Furthermore, the ORs of thyroid cancer for individual external doses of 1 mSv or more and 2 mSv or more, with the external dose less than 1 mSv as reference, were calculated. Prevalence of thyroid cancer for the location groups were 48/100,000 for the highest dose area, 36/100,000 for the middle dose area, and 41/100,000 for the lowest dose area. Compared with the lowest dose area, age-, and sex-adjusted ORs (95% confidence intervals) for the highest-dose and middle-dose areas were 1.49 (0.36-6.23) and 1.00 (0.67-1.50), respectively. The duration between accident and thyroid examination was not associated with thyroid cancer prevalence. There were no significant associations between individual external doses and prevalence of thyroid cancer. External radiation dose was not associated with thyroid cancer prevalence among Fukushima children within the first 4 years after the nuclear accident.

  10. [Investigation of reference intervals of blood gas and acid-base analysis assays in China].

    PubMed

    Zhang, Lu; Wang, Wei; Wang, Zhiguo

    2015-10-01

    To investigate and analyze the upper and lower limits and their sources of reference intervals in blood gas and acid-base analysis assays. The data of reference intervals were collected, which come from the first run of 2014 External Quality Assessment (EQA) program in blood gas and acid-base analysis assays performed by National Center for Clinical Laboratories (NCCL). All the abnormal values and errors were eliminated. Data statistics was performed by SPSS 13.0 and Excel 2007 referring to upper and lower limits of reference intervals and sources of 7 blood gas and acid-base analysis assays, i.e. pH value, partial pressure of carbon dioxide (PCO2), partial pressure of oxygen (PO2), Na+, K+, Ca2+ and Cl-. Values were further grouped based on instrument system and the difference between each group were analyzed. There were 225 laboratories submitting the information on the reference intervals they had been using. The three main sources of reference intervals were National Guide to Clinical Laboratory Procedures [37.07% (400/1 079)], instructions of instrument manufactures [31.23% (337/1 079)] and instructions of reagent manufactures [23.26% (251/1 079)]. Approximately 35.1% (79/225) of the laboratories had validated the reference intervals they used. The difference of upper and lower limits in most assays among 7 laboratories was moderate, both minimum and maximum (i.e. the upper limits of pH value was 7.00-7.45, the lower limits of Na+ was 130.00-156.00 mmol/L), and mean and median (i.e. the upper limits of K+ was 5.04 mmol/L and 5.10 mmol/L, the upper limits of PCO2 was 45.65 mmHg and 45.00 mmHg, 1 mmHg = 0.133 kPa), as well as the difference in P2.5 and P97.5 between each instrument system group. It was shown by Kruskal-Wallis method that the P values of upper and lower limits of all the parameters were lower than 0.001, expecting the lower limits of Na+ with P value 0.029. It was shown by Mann-Whitney that the statistic differences were found among instrument system groups and between most of two instrument system groups in all assays. The difference of reference intervals of blood gas and acid-base analysis assays used in China laboratories is moderate, which is better than other specialties in clinical laboratories.

  11. Selecting and Improving Quasi-Experimental Designs in Effectiveness and Implementation Research.

    PubMed

    Handley, Margaret A; Lyles, Courtney R; McCulloch, Charles; Cattamanchi, Adithya

    2018-04-01

    Interventional researchers face many design challenges when assessing intervention implementation in real-world settings. Intervention implementation requires holding fast on internal validity needs while incorporating external validity considerations (such as uptake by diverse subpopulations, acceptability, cost, and sustainability). Quasi-experimental designs (QEDs) are increasingly employed to achieve a balance between internal and external validity. Although these designs are often referred to and summarized in terms of logistical benefits, there is still uncertainty about (a) selecting from among various QEDs and (b) developing strategies to strengthen the internal and external validity of QEDs. We focus here on commonly used QEDs (prepost designs with nonequivalent control groups, interrupted time series, and stepped-wedge designs) and discuss several variants that maximize internal and external validity at the design, execution and implementation, and analysis stages.

  12. Specificity of relations between children's control-related beliefs and internalizing and externalizing psychopathology.

    PubMed

    Han, S S; Weisz, J R; Weiss, B

    2001-04-01

    The authors examined the specificity of the relation between 3 types of control-related beliefs and internalizing and externalizing psychopathology in a sample of 290 clinic-referred children aged 7 to 17 years. Self-reported beliefs about control (the capacity to cause an intended outcome), contingency (the degree to which a desired outcome can be controlled by a relevant behavior), and competence (an individual's ability to produce the relevant behavior) across 3 domains (academic, behavioral, and social) showed more specific relations with psychopathology than have been previously reported. Among children with externalizing psychopathology, internalizing psychopathology may be specifically associated with increased self-critical awareness about their conduct; externalizing psychopathology may attenuate the specific negative relation between internalizing psychopathology and control-related beliefs in the social domain.

  13. Characteristics of the Single-Longitudinal-Mode Planar-Waveguide External Cavity Diode Laser at 1064 nm

    NASA Technical Reports Server (NTRS)

    Numata, Kenji; Alalusi, Mazin; Stolpner, Lew; Margaritis, Georgios; Camp, Jordan; Krainak, Michael

    2014-01-01

    We describe the characteristics of the planar-waveguide external cavity diode laser (PW-ECL). To the best of our knowledge, it is the first butterfly-packaged 1064 nm semiconductor laser that is stable enough to be locked to an external frequency reference. We evaluated its performance from the viewpoint of precision experiments. Using a hyperfine absorption line of iodine, we suppressed its frequency noise by a factor of up to 104 at 10 mHz. The PWECL's compactness and low cost make it a candidate to replace traditional Nd:YAG nonplanar ring oscillators and fiber lasers in applications that require a single longitudinal mode.

  14. Genetics Home Reference: campomelic dysplasia

    MedlinePlus

    ... have external genitalia that do not look clearly male or clearly female (ambiguous genitalia). Approximately 75 percent of affected individuals with a typical male chromosome pattern (46,XY) have ambiguous genitalia or ...

  15. External Quality Monitoring of the Cervical Cytopathological Exams in the Rio de Janeiro City.

    PubMed

    Rocha, Vânia Stiepanowez de Oliveira; Malfacini, Solange da Silva; Gomes, Alex Moreira; Rocha, Cláudia Ramos Marques da

    2018-06-20

     To discuss the implementation and contributions of the External Quality Monitoring in the city of Rio de Janeiro and to analyze the performance of the main providers of cervical cytopathology in this city from September 2013 to March 2017, here referred to as "Alpha laboratory" and "Beta laboratory."  Observational, cross-sectional, retrospective study using information from the Cervical Cancer Control Information System (SISCOLO, in the Portuguese acronym), municipal coordination module, External Quality Monitoring report. The proportions of false positives, false negatives, unsatisfactory samples and rejected samples were estimated. The agreement among the observers was analyzed through the Kappa index and the reduction of disagreements in the period for each laboratory studied, comparing the results of each cycle.  A total of 19,158 examinations were selected, of which 19,130 (99.85%) were monitored, 16.649 (87, 03%) were reviewed by the External Quality Monitoring Unit, 2,481 (12,97%) were rejected and 441 (2,65%) were considered unsatisfactory. The "Beta laboratory" presented excellent concordance in all cycles; the "Alpha laboratory" had good concordance in the first two cycles (K = 0.76 and 0.79), becoming excellent in the following four cycles. The average Kappa index was 0.85, with median of 0.86. The percentage of diagnostic disagreement was 6.63% of the reviewed exams, of which 5.38% required a change of conduct CONCLUSION:  External Quality Monitoring is an exercise in diagnostic improvement, and its implementation was fundamental to ensure the reliability of the cytopathological exams in the city of Rio de Janeiro. Thieme Revinter Publicações Ltda Rio de Janeiro, Brazil.

  16. Spatial vision within egocentric and exocentric frames of reference

    NASA Technical Reports Server (NTRS)

    Howard, Ian P.

    1991-01-01

    It is remarkable that we are able to perceive a stable visual world and judge the directions, orientations, and movements of visual objects given that images move on the retina, the eyes move in the head, the head moves on the body, and the body moves in space. An understanding of the mechanisms underlying perceptual stability and spatial judgements requires precise definitions of relevant coordinate systems. An egocentric frame of reference is defined with respect to some part of the observer. There are four principal egocentric frames of reference, a station-point frame associated with the nodal point of the eye, an retinocentric frame associated with the retina, a headcentric frame associated with the head, and a bodycentric frame (torsocentric) associated with the torso. Additional egocentric frames can be identified with respect to any segment of the body. An egocentric task is one in which the position, orientation, or motion of an object is judged with respect to an egocentric frame of reference. A proprioceptive is a special kind of egocentric task in which the object being judged is also part of the body. An example of a proprioceptive task is that of directing the gaze toward the seen or unseen toe. An exocentric frame of reference is external to the observer. Geographical coordinates and the direction of gravity are examples of exocentric frames of reference. These various frames are listed in tabular form, together with examples of judgements of each type.

  17. Glucose Monitoring in Individuals With Diabetes Using a Long-Term Implanted Sensor/Telemetry System and Model.

    PubMed

    Lucisano, Joseph Y; Routh, Timothy L; Lin, Joe T; Gough, David A

    2017-09-01

    The use of a fully implanted first-generation prototype sensor/telemetry system is described for long-term monitoring of subcutaneous tissue glucose in a small cohort of people with diabetes. Sensors are based on a membrane containing immobilized glucose oxidase and catalase coupled to oxygen electrodes and a telemetry system, integrated as an implant. The devices remained implanted for up to 180 days, with signals transmitted every 2 min to external receivers. The data include signal recordings from glucose clamps and spontaneous glucose excursions, matched, respectively, to reference blood glucose and finger-stick values. The sensor signals indicate dynamic tissue glucose, for which there is no independent standard, and a model describing the relationship between blood glucose and the signal is, therefore, included. The values of all model parameters have been estimated, including the permeability of adjacent tissues to glucose, and equated to conventional mass transfer parameters. As a group, the sensor calibration varied randomly at an average rate of -2.6%/week. Statistical correlation indicated strong association between the sensor signals and reference glucose values. Continuous long-term glucose monitoring in individuals with diabetes is feasible with this system. All therapies for diabetes are based on glucose control, and therefore, require glucose monitoring. This fully implanted long-term sensor/telemetry system may facilitate a new era of management of the disease.

  18. Glucose Monitoring in Individuals with Diabetes using a Long-Term Implanted Sensor/Telemetry System and Model

    PubMed Central

    Lucisano, Joseph Y.; Routh, Timothy L.; Lin, Joe T.; Gough, David A.

    2017-01-01

    Objective The use of a fully implanted, first-generation prototype sensor/telemetry system is described for long-term monitoring of subcutaneous tissue glucose in a small cohort of people with diabetes. Methods Sensors are based on a membrane containing immobilized glucose oxidase and catalase coupled to oxygen electrodes and a telemetry system, integrated as an implant. The devices remained implanted for up to 180 days, with signals transmitted every 2 minutes to external receivers. Results The data include signal recordings from glucose clamps and spontaneous glucose excursions, matched respectively to reference blood glucose and finger-stick values. The sensor signals indicate dynamic tissue glucose, for which there is no independent standard, and a model describing the relationship between blood glucose and the signal is therefore included. The values of all model parameters have been estimated, including the permeability of adjacent tissues to glucose, and equated to conventional mass transfer parameters. As a group, the sensor calibration varied randomly at an average rate of −2.6%/week. Statistical correlation indicated strong association between the sensor signals and reference glucose values. Conclusions Continuous, long-term glucose monitoring in individuals with diabetes is feasible with this system. Significance All therapies for diabetes are based on glucose control and therefore require glucose monitoring. This fully implanted, long-term sensor/telemetry system may facilitate a new era of management of the disease. PMID:27775510

  19. Critical Infrastructure References: Documented Literature Search

    DTIC Science & Technology

    2012-10-01

    the literature search document can be a resource for DRDC and external partners. Future plans: At present, the electronic copies of the reference...Personal Information Protection and Electronic Documents Act (S.C. 2000, c. 5) Title: Personal Information Protection and Electronic Documents Act (S.C...2011 Overview: • "An Act to support and promote electronic commerce by protecting personal information that is collected, used or disclosed in

  20. Ipsilateral wrist-ankle movements in the sagittal plane encoded in extrinsic reference frame.

    PubMed

    Muraoka, Tetsuro; Ishida, Yuki; Obu, Takashi; Crawshaw, Larry; Kanosue, Kazuyuki

    2013-04-01

    When performing oscillatory movements of two joints in the sagittal plane, there is a directional constraint for performing such movements. Previous studies could not distinguish whether the directional constraint reflected movement direction encoded in the extrinsic (outside the body) reference frame or in the intrinsic (the participants' torso/head) reference frame since participants performed coordinated movements in a sitting position where the torso/head was stationary relative to the external world. In order to discern the reference frame in the present study, participants performed paced oscillatory movements of the ipsilateral wrist and ankle in the sagittal plane in a standing position so that the torso/head moved relative to the external world. The coordinated movements were performed in one of two modes of coordination, moving the hand upward concomitant with either ankle plantarflexion or ankle dorsiflexion. The same directional mode relative to extrinsic space was more stable and accurate as compared with the opposite directional mode. When forearm position was changed from the pronated position to the supinated position, similar results were obtained, indicating that the results were independent of a particular coupling of muscles. These findings suggest that the directional constraint on ipsilateral joints movements in the sagittal plane reflects movement direction encoded in the extrinsic reference frame. Copyright © 2013 Elsevier Ireland Ltd and the Japan Neuroscience Society. All rights reserved.

  1. Design of Test Articles and Monitoring System for the Characterization of HIRF Effects on a Fault-Tolerant Computer Communication System

    NASA Technical Reports Server (NTRS)

    Torres-Pomales, Wilfredo; Malekpour, Mahyar R.; Miner, Paul S.; Koppen, Sandra V.

    2008-01-01

    This report describes the design of the test articles and monitoring systems developed to characterize the response of a fault-tolerant computer communication system when stressed beyond the theoretical limits for guaranteed correct performance. A high-intensity radiated electromagnetic field (HIRF) environment was selected as the means of injecting faults, as such environments are known to have the potential to cause arbitrary and coincident common-mode fault manifestations that can overwhelm redundancy management mechanisms. The monitors generate stimuli for the systems-under-test (SUTs) and collect data in real-time on the internal state and the response at the external interfaces. A real-time health assessment capability was developed to support the automation of the test. A detailed description of the nature and structure of the collected data is included. The goal of the report is to provide insight into the design and operation of these systems, and to serve as a reference document for use in post-test analyses.

  2. Interval stability for complex systems

    NASA Astrophysics Data System (ADS)

    Klinshov, Vladimir V.; Kirillov, Sergey; Kurths, Jürgen; Nekorkin, Vladimir I.

    2018-04-01

    Stability of dynamical systems against strong perturbations is an important problem of nonlinear dynamics relevant to many applications in various areas. Here, we develop a novel concept of interval stability, referring to the behavior of the perturbed system during a finite time interval. Based on this concept, we suggest new measures of stability, namely interval basin stability (IBS) and interval stability threshold (IST). IBS characterizes the likelihood that the perturbed system returns to the stable regime (attractor) in a given time. IST provides the minimal magnitude of the perturbation capable to disrupt the stable regime for a given interval of time. The suggested measures provide important information about the system susceptibility to external perturbations which may be useful for practical applications. Moreover, from a theoretical viewpoint the interval stability measures are shown to bridge the gap between linear and asymptotic stability. We also suggest numerical algorithms for quantification of the interval stability characteristics and demonstrate their potential for several dynamical systems of various nature, such as power grids and neural networks.

  3. Psychopathy as predictor and moderator of multisystemic therapy outcomes among adolescents treated for antisocial behavior.

    PubMed

    Manders, Willeke A; Deković, Maja; Asscher, Jessica J; van der Laan, Peter H; Prins, Pier J M

    2013-10-01

    The aim of the present study was to determine whether psychopathic traits act as a predictor and/or moderator of the effectiveness of Multisystemic Therapy (MST). The sample included N = 256 adolescents (188 boys and 68 girls) referred for conduct problems, randomized to MST or Treatment As Usual (TAU). The mean age was 16 years (SD = 1.31). Assessments were carried out before and immediately after treatment (6 months later). Three psychopathic traits (callous/unemotional traits, narcissism, and impulsiveness) were assessed with parent reports. Adolescents and parents were informants on externalizing problems. MST was more effective than TAU in decreasing externalizing problems for the "lower callous/unemotional" and "lower narcissism" group, but not for the "high callous/unemotional" and "high narcissism" group (moderators). Impulsiveness was found to predict more post-treatment externalizing problems rated by adolescents (predictor), but not more post-treatment externalizing problems rated by parents. These findings point out the clinical relevance of adequately assessing psychopathic traits in adolescents referred for treatment of antisocial behaviour, and identifying those adolescents who show high levels of these traits. It is important to tailor MST specifically to meet the needs of juveniles with high levels of callous/unemotional traits and high levels of narcissism to obtain the same level of effectiveness as with juveniles scoring lower on these traits.

  4. NASAwide electronic publishing system: Electronic printing and duplicating, stage-2 evaluation report (GSFC)

    NASA Technical Reports Server (NTRS)

    Tuey, Richard C.; Lane, Robert; Hart, Susan V.

    1995-01-01

    The NASA Scientific and Technical Information Office was assigned the responsibility to continue with the expansion of the NASAwide networked electronic duplicating effort by including the Goddard Space Flight Center (GSFC) as an additional node to the existing configuration of networked electronic duplicating systems within NASA. The subject of this report is the evaluation of a networked electronic duplicating system which meets the duplicating requirements and expands electronic publishing capabilities without increasing current operating costs. This report continues the evaluation reported in 'NASA Electronic Publishing System - Electronic Printing and Duplicating Evaluation Report' (NASA TM-106242) and 'NASA Electronic Publishing System - Stage 1 Evaluation Report' (NASA TM-106510). This report differs from the previous reports through the inclusion of an external networked desktop editing, archival, and publishing functionality which did not exist with the previous networked electronic duplicating system. Additionally, a two-phase approach to the evaluation was undertaken; the first was a paper study justifying a 90-day, on-site evaluation, and the second phase was to validate, during the 90-day evaluation, the cost benefits and productivity increases that could be achieved in an operational mode. A benchmark of the functionality of the networked electronic publishing system and external networked desktop editing, archival, and publishing system was performed under a simulated daily production environment. This report can be used to guide others in determining the most cost effective duplicating/publishing alternative through the use of cost/benefit analysis and return on investment techniques. A treatise on the use of these techniques can be found by referring to 'NASA Electronic Publishing System -Cost/Benefit Methodology' (NASA TM-106662).

  5. Bipartite flocking for multi-agent systems

    NASA Astrophysics Data System (ADS)

    Fan, Ming-Can; Zhang, Hai-Tao; Wang, Miaomiao

    2014-09-01

    This paper addresses the bipartite flock control problem where a multi-agent system splits into two clusters upon internal or external excitations. Using structurally balanced signed graph theory, LaSalle's invariance principle and Barbalat's Lemma, we prove that the proposed algorithm guarantees a bipartite flocking behavior. In each of the two disjoint clusters, all individuals move with the same direction. Meanwhile, every pair of agents in different clusters moves with opposite directions. Moreover, all agents in the two separated clusters approach a common velocity magnitude, and collision avoidance among all agents is ensured as well. Finally, the proposed bipartite flock control method is examined by numerical simulations. The bipartite flocking motion addressed by this paper has its references in both natural collective motions and human group behaviors such as predator-prey and panic escaping scenarios.

  6. Development of a real-time internal and external marker tracking system for particle therapy: a phantom study using patient tumor trajectory data

    PubMed Central

    Cho, Junsang; Cheon, Wonjoong; Ahn, Sanghee; Jung, Hyunuk; Sheen, Heesoon; Park, Hee Chul

    2017-01-01

    Abstract Target motion–induced uncertainty in particle therapy is more complicated than that in X-ray therapy, requiring more accurate motion management. Therefore, a hybrid motion-tracking system that can track internal tumor motion and as well as an external surrogate of tumor motion was developed. Recently, many correlation tests between internal and external markers in X-ray therapy have been developed; however, the accuracy of such internal/external marker tracking systems, especially in particle therapy, has not yet been sufficiently tested. In this article, the process of installing an in-house hybrid internal/external motion-tracking system is described and the accuracy level of tracking system was acquired. Our results demonstrated that the developed in-house external/internal combined tracking system has submillimeter accuracy, and can be clinically used as a particle therapy system as well as a simulation system for moving tumor treatment. PMID:28201522

  7. TREAT Asia Quality Assessment Scheme (TAQAS) to standardize the outcome of HIV genotypic resistance testing in a group of Asian laboratories

    PubMed Central

    Land, Sally; Cunningham, Philip; Zhou, Jialun; Frost, Kevin; Katzenstein, David; Kantor, Rami; Chen, Yi-Ming Arthur; Oka, Shinichi; DeLong, Allison; Sayer, David; Smith, Jeffery; Dax, Elizabeth M.; Law, Matthew

    2010-01-01

    The TREAT Asia (Therapeutics, Research, Education, and AIDS Training in Asia) Network is building capacity for Human Immunodeficiency Virus Type-1 (HIV-1) drug resistance testing in the region. The objective of the TREAT Asia Quality Assessment Scheme – designated TAQAS – is to standardize HIV-1 genotypic resistance testing (HIV genotyping) among laboratories to permit rigorous comparison of results from different clinics and testing centres. TAQAS has evaluated three panels of HIV-1-positive plasma from clinical material or low-passage, culture supernatant for up to 10 Asian laboratories. Laboratory participants used their standard protocols to perform HIV genotyping. Assessment was in comparison to a target genotype derived from all participants and the reference laboratory’s result. Agreement between most participants at the edited nucleotide sequence level was high (>98%). Most participants performed to the reference laboratory standard in detection of drug resistance mutations (DRMs). However, there was variation in the detection of nucleotide mixtures (0–83%) and a significant correlation with the detection of DRMs (p < 0.01). Interpretation of antiretroviral resistance showed ~70% agreement among participants when different interpretation systems were used but >90% agreement with a common interpretation system, within the Stanford University Drug Resistance Database. Using the principles of external quality assessment and a reference laboratory, TAQAS has demonstrated high quality HIV genotyping results from Asian laboratories. PMID:19490972

  8. An Adaptive Low-Cost GNSS/MEMS-IMU Tightly-Coupled Integration System with Aiding Measurement in a GNSS Signal-Challenged Environment.

    PubMed

    Zhou, Qifan; Zhang, Hai; Li, You; Li, Zheng

    2015-09-18

    The main aim of this paper is to develop a low-cost GNSS/MEMS-IMU tightly-coupled integration system with aiding information that can provide reliable position solutions when the GNSS signal is challenged such that less than four satellites are visible in a harsh environment. To achieve this goal, we introduce an adaptive tightly-coupled integration system with height and heading aiding (ATCA). This approach adopts a novel redundant measurement noise estimation method for an adaptive Kalman filter application and also augments external measurements in the filter to aid the position solutions, as well as uses different filters to deal with various situations. On the one hand, the adaptive Kalman filter makes use of the redundant measurement system's difference sequence to estimate and tune noise variance instead of employing a traditional innovation sequence to avoid coupling with the state vector error. On the other hand, this method uses the external height and heading angle as auxiliary references and establishes a model for the measurement equation in the filter. In the meantime, it also changes the effective filter online based on the number of tracked satellites. These measures have increasingly enhanced the position constraints and the system observability, improved the computational efficiency and have led to a good result. Both simulated and practical experiments have been carried out, and the results demonstrate that the proposed method is effective at limiting the system errors when there are less than four visible satellites, providing a satisfactory navigation solution.

  9. SU-F-J-10: Sliding Mode Control of a SMA Actuated Active Flexible Needle for Medical Procedures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Podder, T

    Purpose: In medical interventional procedures such as brachytherapy, ablative therapies and biopsy precise steering and accurate placement of needles are very important for anatomical obstacle avoidance and accurate targeting. This study presents the efficacy of a sliding mode controller for Shape Memory Alloy (SMA) actuated flexible needle for medical procedures. Methods: Second order system dynamics of the SMA actuated active flexible needle was used for deriving the sliding mode control equations. Both proportional-integral-derivative (PID) and adaptive PID sliding mode control (APIDSMC) algorithms were developed and implemented. The flexible needle was attached at the end of a 6 DOF robotic system.more » Through LabView programming environment, the control commands were generated using the PID and APIDSMC algorithms. Experiments with artificial tissue mimicking phantom were performed to evaluate the performance of the controller. The actual needle tip position was obtained using an electromagnetic (EM) tracking sensor (Aurora, NDI, waterloo, Canada) at a sampling period of 1ms. During experiment, external disturbances were created applying force and thermal shock to investigate the robustness of the controllers. Results: The root mean square error (RMSE) values for APIDSMC and PID controllers were 0.75 mm and 0.92 mm, respectively, for sinusoidal reference input. In the presence of external disturbances, the APIDSMC controller showed much smoother and less overshooting response compared to that of the PID controller. Conclusion: Performance of the APIDSMC was superior to the PID controller. The APIDSMC was proved to be more effective controller in compensating the SMA uncertainties and external disturbances with clinically acceptable thresholds.« less

  10. External ultrasonography of the neck does not add diagnostic value to integrated positron emission tomography-computed tomography (PET-CT) scanning in the diagnosis of cervical lymph node metastases in patients with esophageal carcinoma.

    PubMed

    Blom, R L G M; Vliegen, R F A; Schreurs, W M J; Belgers, H J; Stohr, I; Oostenbrug, L E; Sosef, M N

    2012-08-01

    One of the objectives of preoperative imaging in esophageal cancer patients is the detection of cervical lymph node metastases. Traditionally, external ultrasonography of the neck has been combined with computed tomography (CT) in order to improve the detection of cervical metastases. In general, integrated positron emission tomography-computed tomography (PET-CT) has been shown to be superior to CT or PET regarding staging and therefore may limit the role of external ultrasonography of the neck. The objective of this study was to determine the additional value of external ultrasonography of the neck to PET-CT. This study included all patients referred our center for treatment of esophageal carcinoma. Diagnostic staging was performed to determine treatment plan. Cervical lymph nodes were evaluated by external ultrasonography of the neck and PET-CT. In case of suspect lymph nodes on external ultrasonography or PET-CT, fine needle aspiration (FNA) was performed. Between 2008 and 2010, 170 out of 195 referred patients underwent both external ultrasonography of the neck and PET-CT. Of all patients, 84% were diagnosed with a tumor at or below the distal esophagus. In 140 of 170 patients, the cervical region was not suspect; no FNA was performed. Seven out of 170 patients had suspect nodes on both PET-CT and external ultrasonography. Five out of seven patients had cytologically confirmed malignant lymph nodes, one of seven had benign nodes, in one patient FNA was not performed; exclusion from esophagectomy was based on intra-abdominal metastases. In one out of 170 patients, PET-CT showed suspect nodes combined with a negative external ultrasonography; cytology of these nodes was benign. Twenty-two out of 170 patients had a negative PET-CT with suspect nodes on external ultrasonography. In 18 of 22 patients, cervical lymph nodes were cytologically confirmed benign; in four patients, FNA was not possible or inconclusive. At a median postoperative follow-up of 15 months, only 1% of patients developed cervical lymph node metastases. This study shows no additional value of external ultrasonography to a negative PET-CT. According to our results, it can be omitted in the primary workup. However, suspect lymph nodes on PET-CT should be confirmed by FNA to exclude false positives if it would change treatment plan. © 2011 Copyright the Authors. Journal compilation © 2011, Wiley Periodicals, Inc. and the International Society for Diseases of the Esophagus.

  11. Interpretation of long- and short-wavelength magnetic anomalies

    USGS Publications Warehouse

    DeNoyer, John M.; Barringer, Anthony R.

    1980-01-01

    Magset was launched on October 30, 1979. More than a decade of examining existing data, devising appropriate models of the global magnetic field, and extending methods for interpreting long-wavelength magnetic anomalies preceded this launch Magnetic data collected by satellite can be interrupted by using a method of analysis that quantitively describes the magnetic field resulting from three-dimensional geologic structures that are bounded by an arbitrary number of polygonal faces, Each face my have any orientation and three or more sides. At each point of the external field, the component normal to each face is obtained by using an expression for the solid angle subtended by a generalized polygon. The "cross" of tangential components are relatively easy to obtain for the same polygons. No approximations have been made related to orbit height that restrict the dimensions of the polygons relative to the distance from the external field points. This permits the method to be used to model shorter wavelength anomalies obtained from aircraft or ground surveys. The magnetic fields for all the structures considered are determine in the same rectangular coordinate system. The coordinate system is in depended from the orientation of geologic trends and permits multiple structures or bodies to be included in the same magnetic field calculations. This single reference system also simplified adjustments in position and direction to account for earth curvature in regional interpretation.

  12. 78 FR 16300 - Agency Information Collection Activities: Submission for OMB Review; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-14

    ... data collection efforts. Methodological findings may be presented externally in technical papers at... individual survey may represent several methodological improvement projects. \\2\\ This number refers to the...

  13. Requirements for data integration platforms in biomedical research networks: a reference model.

    PubMed

    Ganzinger, Matthias; Knaup, Petra

    2015-01-01

    Biomedical research networks need to integrate research data among their members and with external partners. To support such data sharing activities, an adequate information technology infrastructure is necessary. To facilitate the establishment of such an infrastructure, we developed a reference model for the requirements. The reference model consists of five reference goals and 15 reference requirements. Using the Unified Modeling Language, the goals and requirements are set into relation to each other. In addition, all goals and requirements are described textually in tables. This reference model can be used by research networks as a basis for a resource efficient acquisition of their project specific requirements. Furthermore, a concrete instance of the reference model is described for a research network on liver cancer. The reference model is transferred into a requirements model of the specific network. Based on this concrete requirements model, a service-oriented information technology architecture is derived and also described in this paper.

  14. Recognition for positive behavior as a critical youth development construct: conceptual bases and implications on youth service development.

    PubMed

    Law, Ben M F; Siu, Andrew M H; Shek, Daniel T L

    2012-01-01

    Recognition for positive behavior is an appropriate response of the social environment to elicit desirable external behavior among the youth. Such positive responses, rendered from various social systems, include tangible and intangible reinforcements. The following theories are used to explain the importance of recognizing positive behavior: operational conditioning, observational learning, self-determination, and humanistic perspective. In the current work, culturally and socially desirable behaviors are discussed in detail with reference to Chinese adolescents. Positive behavior recognition is especially important to adolescent development because it promotes identity formation as well as cultivates moral reasoning and social perspective thinking from various social systems. The significance of recognizing positive behavior is illustrated through the support, tutorage, invitation, and subsidy provided by Hong Kong's social systems in recognition of adolescent volunteerism. The practical implications of positive behavior recognition on youth development programs are also discussed in this work.

  15. Timing in a FLASH

    NASA Astrophysics Data System (ADS)

    Hoek, M.; Cardinali, M.; Corell, O.; Dickescheid, M.; Ferretti B., M. I.; Lauth, W.; Schlimme, B. S.; Sfienti, C.; Thiel, M.

    2017-12-01

    A prototype detector, called FLASH (Fast Light Acquiring Start Hodoscope), was built to provide precise Time-of-Flight (TOF) measurements and reference timestamps for detector setups at external beam lines. Radiator bars, made of synthetic fused silica, were coupled to a fast MCP-PMT with 64 channels and read out with custom electronics using Time-over-Threshold (TOT) for signal characterization. The TRB3 system, a high-precision TDC implemented in an FPGA, was used as data acquisition system. The performance of a system consisting of two FLASH units was investigated at a dedicated test experiment at the Mainz Microtron (MAMI) accelerator using its 855 MeV electron beam. The TOT measurement enabled time walk corrections and an overall TOF resolution of ∼70 ps could be achieved which translates into a resolution of ∼50 ps per FLASH unit. The intrinsic resolution of the frontend electronics including the TDC was measured to be less than 25 ps.

  16. Space Communication and Navigation Testbed Communications Technology for Exploration

    NASA Technical Reports Server (NTRS)

    Reinhart, Richard

    2013-01-01

    NASA developed and launched an experimental flight payload (referred to as the Space Communication and Navigation Test Bed) to investigate software defined radio, networking, and navigation technologies, operationally in the space environment. The payload consists of three software defined radios each compliant to NASAs Space Telecommunications Radio System Architecture, a common software interface description standard for software defined radios. The software defined radios are new technology developed by NASA and industry partners. The payload is externally mounted to the International Space Station truss and available to NASA, industry, and university partners to conduct experiments representative of future mission capability. Experiment operations include in-flight reconfiguration of the SDR waveform functions and payload networking software. The flight system communicates with NASAs orbiting satellite relay network, the Tracking, Data Relay Satellite System at both S-band and Ka-band and to any Earth-based compatible S-band ground station.

  17. [Effectiveness of incorporating a quality management system].

    PubMed

    Seki, Akira; Hankins, Raleigh W; Miya, Tetsumasa

    2010-01-01

    In 2003, the ISO 15189 international standardization program on the quality and competence of the clinical reference laboratory was introduced. To date, 46 facilities have committed themselves to providing a higher level of medical service by incorporating a quality management system (QMS) and acquiring accreditation. QMS is defined as "setting up a policy and goals pertaining to quality, and adopting an appropriate system," and is a scheme that includes all managerial and technical factors that can affect test results. Regarding the Health Sciences Research Institute Group, 4 facilities have previously received the accreditation described above, but in the process of implementing the QMS, a number of problems have been identified. Here, we report on the effectiveness of adopting such a QMS based on the results of employee questionnaires, internal audits, customer complaint analyses, and external audits by the Japan Accreditation Board for Conformity Assessment (JAB), the official inspection body for accreditation.

  18. The structure of antimalarial dispiro-1,2,4-trioxolanes: A density functional approach

    NASA Astrophysics Data System (ADS)

    Moroni, L.; Salvi, P. R.

    2006-02-01

    Ab initio DF/B3-LYP/cc-pVDZ calculations have been performed on three dispiro-1,2,4-trioxolane systems ( 2)-( 4). Interest in these systems comes from the fact that a water-soluble derivative of ( 3), known as OZ277, has been synthesized and identified as antimalarial drug with activity superior to those of semisynthetic artemisinins. Structural data have been obtained regarding the atomic arrangement around the peroxide bond for the three systems. Making reference to ( 3), two conformers have been calculated depending on the axial or equatorial bond of spirocyclohexane with the peroxide oxygen of 1,2,4-trioxolane. In particular, while the peroxide oxygen on the spiroadamantane side is sterically hindered for both the axial and the equatorial conformer, the peroxide oxygen on the spirocyclohexane side is more accessible to external attack when the conformer is axial than when is equatorial.

  19. Combinatorial electrochemical synthesis and screening of Pt-WO3 catalysts for electro-oxidation of methanol

    NASA Astrophysics Data System (ADS)

    Jayaraman, Shrisudersan; Baeck, Sung-Hyeon; Jaramillo, Thomas F.; Kleiman-Shwarsctein, Alan; McFarland, Eric W.

    2005-06-01

    An automated system for high-throughput electrochemical synthesis and screening of fuel cell electro-oxidation catalysts is described. This system consists of an electrode probe that contains counter and reference electrodes that can be positioned inside an array of electrochemical cells created within a polypropylene block. The electrode probe is attached to an automated of X-Y-Z motion system. An externally controlled potentiostat is used to apply the electrochemical potential to the catalyst substrate. The motion and electrochemical control are integrated using a user-friendly software interface. During automated synthesis the deposition potential and/or current may be controlled by a pulse program triggered by the software using a data acquisition board. The screening includes automated experiments to obtain cyclic voltammograms. As an example, a platinum-tungsten oxide (Pt-WO3) library was synthesized and characterized for reactivity towards methanol electro-oxidation.

  20. A cybernetic theory of morality and moral autonomy.

    PubMed

    Chambers, J

    2001-04-01

    Human morality may be thought of as a negative feedback control system in which moral rules are reference values, and moral disapproval, blame, and punishment are forms of negative feedback given for violations of the moral rules. In such a system, if moral agents held each other accountable, moral norms would be enforced effectively. However, even a properly functioning social negative feedback system could not explain acts in which individual agents uphold moral rules in the face of contrary social pressure. Dr. Frances Kelsey, who withheld FDA approval for thalidomide against intense social pressure, is an example of the degree of individual moral autonomy possible in a hostile environment. Such extreme moral autonomy is possible only if there is internal, psychological negative feedback, in addition to external, social feedback. Such a cybernetic model of morality and moral autonomy is consistent with certain aspects of classical ethical theories.

  1. Mapping Farming Practices in Belgian Intensive Cropping Systems from Sentinel-1 SAR Time Series

    NASA Astrophysics Data System (ADS)

    Chome, G.; Baret, P. V.; Defourny, P.

    2016-08-01

    The environmental impact of the so-called conventional farming system calls for new farming practices reducing negative externalities. Emerging farming practices such as no-till and new inter-cropping management are promising tracks. The development of methods to characterize crop management across an entire region and to understand their spatial dimension offers opportunities to accompany the transition towards a more sustainable agriculture.This research takes advantage of the unmatched polarimetric and temporal resolutions of Sentinel-1 SAR C- band to develop a method to identify farming practices at the parcel level. To this end, the detection of changes in backscattering due to surface roughness modification (tillage, inter-crop cover destruction ...) is used to detect the farming management. The final results are compared to a reference dataset collected through an intensive field campaign. Finally, the performances are discussed in the perspective of practices monitoring of cropping systems through remote sensing.

  2. Recognition for Positive Behavior as a Critical Youth Development Construct: Conceptual Bases and Implications on Youth Service Development

    PubMed Central

    Law, Ben M. F.; Siu, Andrew M. H.; Shek, Daniel T. L.

    2012-01-01

    Recognition for positive behavior is an appropriate response of the social environment to elicit desirable external behavior among the youth. Such positive responses, rendered from various social systems, include tangible and intangible reinforcements. The following theories are used to explain the importance of recognizing positive behavior: operational conditioning, observational learning, self-determination, and humanistic perspective. In the current work, culturally and socially desirable behaviors are discussed in detail with reference to Chinese adolescents. Positive behavior recognition is especially important to adolescent development because it promotes identity formation as well as cultivates moral reasoning and social perspective thinking from various social systems. The significance of recognizing positive behavior is illustrated through the support, tutorage, invitation, and subsidy provided by Hong Kong's social systems in recognition of adolescent volunteerism. The practical implications of positive behavior recognition on youth development programs are also discussed in this work. PMID:22666155

  3. Synthetic Vision System Commercial Aircraft Flight Deck Display Technologies for Unusual Attitude Recovery

    NASA Technical Reports Server (NTRS)

    Prinzel, Lawrence J., III; Ellis, Kyle E.; Arthur, Jarvis J.; Nicholas, Stephanie N.; Kiggins, Daniel

    2017-01-01

    A Commercial Aviation Safety Team (CAST) study of 18 worldwide loss-of-control accidents and incidents determined that the lack of external visual references was associated with a flight crew's loss of attitude awareness or energy state awareness in 17 of these events. Therefore, CAST recommended development and implementation of virtual day-Visual Meteorological Condition (VMC) display systems, such as synthetic vision systems, which can promote flight crew attitude awareness similar to a day-VMC environment. This paper describes the results of a high-fidelity, large transport aircraft simulation experiment that evaluated virtual day-VMC displays and a "background attitude indicator" concept as an aid to pilots in recovery from unusual attitudes. Twelve commercial airline pilots performed multiple unusual attitude recoveries and both quantitative and qualitative dependent measures were collected. Experimental results and future research directions under this CAST initiative and the NASA "Technologies for Airplane State Awareness" research project are described.

  4. Skin conductance level reactivity moderates the association between harsh parenting and growth in child externalizing behavior.

    PubMed

    Erath, Stephen A; El-Sheikh, Mona; Hinnant, J Benjamin; Cummings, E Mark

    2011-05-01

    Skin conductance level reactivity (SCLR) was examined as a moderator of the association between harsh parenting at age 8 years and growth in child externalizing behavior from age 8 to age 10 (N = 251). Mothers and fathers provided reports of harsh parenting and their children's externalizing behavior; children also provided reports of harsh parenting. SCLR was assessed in response to a socioemotional stress task and a problem-solving challenge task. Latent growth modeling revealed that boys with higher harsh parenting in conjunction with lower SCLR exhibited relatively high and stable levels of externalizing behavior during late childhood. Boys with higher harsh parenting and higher SCLR exhibited relatively low to moderate levels of externalizing behavior at age 8, but some results suggested that their externalizing behavior increased over time, approaching the same levels as boys with higher harsh parenting and lower SCLR by age 10. For the most part, girls and boys with lower harsh parenting were given relatively low and stable ratings of externalizing behavior throughout late childhood. Results are discussed from a developmental psychopathology perspective with reference to models of antisocial behavior in childhood. (c) 2011 APA, all rights reserved.

  5. Skin Conductance Level Reactivity Moderates the Association Between Harsh Parenting and Growth in Child Externalizing Behavior

    PubMed Central

    Erath, Stephen A.; El-Sheikh, Mona; Hinnant, J. Benjamin; Cummings, E. Mark

    2011-01-01

    Skin conductance level reactivity (SCLR) was examined as a moderator of the association between harsh parenting at age 8 years and growth in child externalizing behavior from age 8 to age 10 (N = 251). Mothers and fathers provided reports of harsh parenting and their children’s externalizing behavior; children also provided reports of harsh parenting. SCLR was assessed in response to a socioemotional stress task and a problem-solving challenge task. Latent growth modeling revealed that boys with higher harsh parenting in conjunction with lower SCLR exhibited relatively high and stable levels of externalizing behavior during late childhood. Boys with higher harsh parenting and higher SCLR exhibited relatively low to moderate levels of externalizing behavior at age 8, but some results suggested that their externalizing behavior increased over time, approaching the same levels as boys with higher harsh parenting and lower SCLR by age 10. For the most part, girls and boys with lower harsh parenting were given relatively low and stable ratings of externalizing behavior throughout late childhood. Results are discussed from a developmental psychopathology perspective with reference to models of antisocial behavior in childhood. PMID:21142369

  6. Gas Sensors Based on Single-Arm Waveguide Interferometers

    NASA Technical Reports Server (NTRS)

    Sarkisov, Sergey; Curley, Michael; Diggs, Darnell; Adamovsky, Grigory

    1998-01-01

    Various optical technologies can be implemented in chemical sensing. Sensitive, rugged, and compact systems will be more likely built using interferometric waveguide sensors. Currently existing sensors comprise dual-arm systems with external reference arm, dual-arm devices with internal reference arm such as integrated Mach-Zehnder interferometer, and single-arm systems which employ the interference between different waveguide modes. These latter ones are the most compact and rugged but still sensitive enough to monitor volatile pollutants such as NH3 coming out of industrial refrigerators and fertilizer plants and stocks, NO, NO2, SO2, emitted by industrial burning processes. Single-arm devices in planar waveguide configuration most frequently use two orthogonally polarized modes TE (sub i) and TM (sub i) of the same order i. Sensing effect is based on the difference in propagation conditions for the modes caused by the environment. However, dual-mode single-order interferometers still have relatively low sensitivity with respect to the environment related changes in the waveguide core because of small difference between propagation constants of TE (sub i) and TM (sub i) modes of the same order. Substantial sensitivity improvement without significant complication can be achieved for planar waveguide interferometers using modes of different orders with much greater difference between propagation constants.

  7. Reconceptualizing antisocial deviance in neurobehavioral terms.

    PubMed

    Patrick, Christopher J; Durbin, C Emily; Moser, Jason S

    2012-08-01

    We propose that neuroscientific understanding of antisocial behavior can be advanced by focusing programmatic efforts on neurobehavioral trait constructs, that is, individual difference constructs with direct referents in neurobiology as well as behavior. As specific examples, we highlight inhibitory control and defensive reactivity as two such constructs with clear relevance for understanding antisocial behavior in the context of development. Variations in inhibitory control are theorized to reflect individual differences in the functioning of brain systems that operate to guide and inhibit behavior and regulate emotional response in the service of nonimmediate goals. Variations in defensive reactivity are posited to reflect individual differences in the sensitivity of the brain's aversive motivational (fear) system. We describe how these constructs have been conceptualized in the adult and child literatures and review work pertaining to traditional psychometric (rating and behaviorally based) assessment of these constructs and their known physiological correlates at differing ages as well as evidence linking these constructs to antisocial behavior problems in children and adults. We outline a psychoneurometric approach, which entails systematic development of neurobiological measures of target trait constructs through reference to psychological phenotypes, as a paradigm for linking clinical disorders to neurobiological systems. We provide a concrete illustration of this approach in the domain of externalizing proneness and discuss its broader implications for research on conduct disorder, antisocial personality, and psychopathy.

  8. New alternatives for reference evapotranspiration estimation in West Africa using limited weather data and ancillary data supply strategies.

    NASA Astrophysics Data System (ADS)

    Landeras, Gorka; Bekoe, Emmanuel; Ampofo, Joseph; Logah, Frederick; Diop, Mbaye; Cisse, Madiama; Shiri, Jalal

    2018-05-01

    Accurate estimation of reference evapotranspiration ( ET 0 ) is essential for the computation of crop water requirements, irrigation scheduling, and water resources management. In this context, having a battery of alternative local calibrated ET 0 estimation methods is of great interest for any irrigation advisory service. The development of irrigation advisory services will be a major breakthrough for West African agriculture. In the case of many West African countries, the high number of meteorological inputs required by the Penman-Monteith equation has been indicated as constraining. The present paper investigates for the first time in Ghana, the estimation ability of artificial intelligence-based models (Artificial Neural Networks (ANNs) and Gene Expression Programing (GEPs)), and ancillary/external approaches for modeling reference evapotranspiration ( ET 0 ) using limited weather data. According to the results of this study, GEPs have emerged as a very interesting alternative for ET 0 estimation at all the locations of Ghana which have been evaluated in this study under different scenarios of meteorological data availability. The adoption of ancillary/external approaches has been also successful, moreover in the southern locations. The interesting results obtained in this study using GEPs and some ancillary approaches could be a reference for future studies about ET 0 estimation in West Africa.

  9. Handball load and shoulder injury rate: a 31-week cohort study of 679 elite youth handball players.

    PubMed

    Møller, M; Nielsen, R O; Attermann, J; Wedderkopp, N; Lind, M; Sørensen, H; Myklebust, G

    2017-02-01

    Knowledge of injury patterns, an essential step towards injury prevention, is lacking in youth handball. To investigate if an increase in handball load is associated with increased shoulder injury rates compared with a minor increase or decrease, and if an association is influenced by scapular control, isometric shoulder strength or glenohumeral range of motion (ROM). 679 players (14-18 years) provided weekly reports on shoulder injury and handball load (training and competition hours) over 31 weeks using the SMS, phone and medical examination system. Handball load in a given week was categorised into (1) <20% increase or decrease (reference), (2) increase between 20% and 60% and (3) increase >60% relative to the weekly average amount of handball load the preceding 4 weeks. Assessment of shoulder isometric rotational and abduction strength, ROM and scapular control was performed at baseline and midseason. An increase in handball load by >60% was associated with greater shoulder injury rate (HR 1.91; 95% CI 1.00 to 3.70, p=0.05) compared with the reference group. The effect of an increase in handball load between 20% and 60% was exacerbated among players with reduced external rotational strength (HR 4.0; 95% CI 1.1 to 15.2, p=0.04) or scapular dyskinesis (HR 4.8; 95% CI 1.3 to 18.3, p=0.02). Reduced external rotational strength exacerbated the effect of an increase above 60% (HR 4.2; 95% CI 1.4 to 12.8, p=0.01). A large increase in weekly handball load increases the shoulder injury rate in elite youth handball players; particularly, in the presence of reduced external rotational strength or scapular dyskinesis. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  10. Characteristics of the Single-Longitudinal-Mode Planar-Waveguide External Cavity Diode Laser at 1064 nm

    NASA Technical Reports Server (NTRS)

    Numata, Kenji; Alalusi, Mazin; Stolpner, Lew; Margaritis, Georgios; Camp, Jordan B.; Krainak, Michael A.

    2014-01-01

    We describe the characteristics of the planar-waveguide external cavity diode laser (PW-ECL). To the best of our knowledge, it is the first butterfly-packaged 1064-nm semiconductor laser that is stable enough to be locked to an external frequency reference. We evaluated its performance from the viewpoint of precision experiments. Especially, using a hyperfine absorption line of iodine, we suppressed its frequency noise by a factor of up to104 at 10 mHz. The PW-ECLs compactness and low cost make it a candidate to replace traditional Nd:YAGnon-planar ring oscillators and fiber lasers in applications which require a single longitudinal-mode.

  11. Advanced Instrumentation, Information, and Control Systems Technologies Pathway: FY 2016 External Review

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thomas, Kenneth David; Hallbert, Bruce Perry

    2016-11-01

    This report describes an External Review conducted by the LWRS Program Advanced Instrumentation, Information, and Control (II&C) Systems Technologies Pathway to solicit feedback on the topics and results of the ongoing II&C research program. This review was held in conjunction with the Nuclear Energy Institute (NEI) Digital I&C Working Group meeting that was held at Idaho National Laboratory (INL) on August 9-10, 2016. Given the opportunity to visit INL and see the pathway research projects, NEI agreed that the Working Group would serve as the External Review panel for the purpose of obtaining expert input on the value and timingmore » of the research projects. This consisted of demonstrations in the Human Systems Simulation Laboratory followed by presentations on the II&C research program in general as well as the five technology development areas. Following the meeting, the presentations were sent to each of the attendees so they could review them in more detail and refer to them in completing the feedback form. Follow-up activities were conducted with the attendees following the meeting to obtain the completed feedback forms. A total of 13 forms were returned. The feedback forms were reviewed by the pathway to compile the data and comments received, which are documented in the report. In all, the feedback provided by the External Review participants is taken to be a strong endorsement of the types of projects being conducted by the pathway, the value they hold for the nuclear plants, and the general timing of need. The feedback aligns well with the priorities, levels of efforts allocated for the research projects, and project schedules. The feedback also represents realistic observations on the practicality of some aspects of implementing these technologies. In some cases, the participants provided thoughtful challenges to certain assumptions in the formulation of the technologies or in deployment plans. These deserve further review and revision of plans if warranted. The pathway will take all of the feedback and address the open issues that have been identified by the participants. This includes 11 actionable items for follow up by the II&C Pathway.« less

  12. [Practical implementation of a quality management system in a radiological department].

    PubMed

    Huber, S; Zech, C J

    2011-10-01

    This article describes the architecture of a project aiming to implement a DIN EN ISO 9001 quality management system in a radiological department. It is intended to be a practical guide to demonstrate each step of the project leading to certification of the system. In a planning phase resources for the implementation of the project have to be identified and a quality management (QM) group as core team has to be formed. In the first project phase all available documents have to be checked and compiled in the QM manual. Moreover all relevant processes of the department have to be described in so-called process descriptions. In a second step responsibilities for the project are identified. Customer and employee surveys have to be carried out and a nonconformity management system has to be implemented. In this phase internal audits are also needed to check the new QM system, which is finally tested in the external certification audit with reference to its conformity with the standards.

  13. Activation of Oxygen and Hydrogen Peroxide by Copper(II) Coupled with Hydroxylamine for Oxidation of Organic Contaminants.

    PubMed

    Lee, Hongshin; Lee, Hye-Jin; Seo, Jiwon; Kim, Hyung-Eun; Shin, Yun Kyung; Kim, Jae-Hong; Lee, Changha

    2016-08-02

    This study reports that the combination of Cu(II) with hydroxylamine (HA) (referred to herein as Cu(II)/HA system) in situ generates H2O2 by reducing dissolved oxygen, subsequently producing reactive oxidants through the reaction of Cu(I) with H2O2. The external supply of H2O2 to the Cu(II)/HA system (i.e., the Cu(II)/H2O2/HA system) was found to further enhance the production of reactive oxidants. Both the Cu(II)/HA and Cu(II)/H2O2/HA systems effectively oxidized benzoate (BA) at pH between 4 and 8, yielding a hydroxylated product, p-hydroxybenzoate (pHBA). The addition of a radical scavenger, tert-butyl alcohol, inhibited the BA oxidation in both systems. However, electron paramagnetic resonance (EPR) spectroscopy analysis indicated that (•)OH was not produced under either acidic or neutral pH conditions, suggesting that the alternative oxidant, cupryl ion (Cu(III)), is likely a dominant oxidant.

  14. An evaluation method of the sustainability of water resource in karst region: a case study of Zunyi, China

    NASA Astrophysics Data System (ADS)

    Li, Bo; Wang, Ganlu; Ding, Hanghang; Chen, Yulong

    2017-06-01

    Water resource is of great significance to the survival and development of human. However, the water resource system in karst regions is sensitive to external interference owing to the special geological processes which cause soil impoverishment, severe rocky desertification and large topographic height difference. Therefore, evaluating the sustainability of the water resource in karst regions is beneficial to reasonably use and protect water resource. This paper puts forward to evaluate the water resource from four aspects, including water resources system, water requirement system, ecosystem and social economic system. Moreover, on this basis, 18 evaluation indexes were selected to construct the sustainability evaluation index system and method. This method was used to evaluate the sustainability of the water resource in the typical karst region—Zunyi, Guizhou province, China, and was verified according to the actual situation in the research area. All these provide reference for the evaluation of the sustainability of the water resource in similar regions.

  15. Performance of electrolyte measurements assessed by a trueness verification program.

    PubMed

    Ge, Menglei; Zhao, Haijian; Yan, Ying; Zhang, Tianjiao; Zeng, Jie; Zhou, Weiyan; Wang, Yufei; Meng, Qinghui; Zhang, Chuanbao

    2016-08-01

    In this study, we analyzed frozen sera with known commutabilities for standardization of serum electrolyte measurements in China. Fresh frozen sera were sent to 187 clinical laboratories in China for measurement of four electrolytes (sodium, potassium, calcium, and magnesium). Target values were assigned by two reference laboratories. Precision (CV), trueness (bias), and accuracy [total error (TEa)] were used to evaluate measurement performance, and the tolerance limit derived from the biological variation was used as the evaluation criterion. About half of the laboratories used a homogeneous system (same manufacturer for instrument, reagent and calibrator) for calcium and magnesium measurement, and more than 80% of laboratories used a homogeneous system for sodium and potassium measurement. More laboratories met the tolerance limit of imprecision (coefficient of variation [CVa]) than the tolerance limits of trueness (biasa) and TEa. For sodium, calcium, and magnesium, the minimal performance criterion derived from biological variation was used, and the pass rates for total error were approximately equal to the bias (<50%). For potassium, the pass rates for CV and TE were more than 90%. Compared with the non homogeneous system, the homogeneous system was superior for all three quality specifications. The use of commutable proficiency testing/external quality assessment (PT/EQA) samples with values assigned by reference methods can monitor performance and provide reliable data for improving the performance of laboratory electrolyte measurement. The homogeneous systems were superior to the non homogeneous systems, whereas accuracy of assigned values of calibrators and assay stability remained challenges.

  16. The impact of change in albumin assay on reference intervals, prevalence of 'hypoalbuminaemia' and albumin prescriptions.

    PubMed

    Coley-Grant, Deon; Herbert, Mike; Cornes, Michael P; Barlow, Ian M; Ford, Clare; Gama, Rousseau

    2016-01-01

    We studied the impact on reference intervals, classification of patients with hypoalbuminaemia and albumin infusion prescriptions on changing from a bromocresol green (BCG) to a bromocresol purple (BCP) serum albumin assay. Passing-Bablok regression analysis and Bland-Altman plot were used to compare Abbott BCP and Roche BCG methods. Linear regression analysis was used to compare in-house and an external laboratory Abbott BCP serum albumin results. Reference intervals for Abbott BCP serum albumin were derived in two different laboratories using pathology data from adult patients in primary care. Prescriptions for 20% albumin infusions were compared one year before and one year after changing the albumin method. Abbott BCP assay had a negative bias of approximately 6 g/L compared with Roche BCG method.There was good agreement (y = 1.04 x - 1.03; R(2 )= 0.9933) between in-house and external laboratory Abbott BCP results. Reference intervals for the serum albumin Abbott BCP assay were 31-45 g/L, different to those recommended by Pathology Harmony and the manufacturers (35-50 g/L). Following the change in method there was a large increase in the number of patients classified as hypoalbuminaemic using Pathology Harmony references intervals (32%) but not when retrospectively compared to locally derived reference intervals (16%) compared with the previous year (12%). The method change was associated with a 44.6% increase in albumin prescriptions. This equated to an annual increase in expenditure of £35,234. We suggest that serum albumin reference intervals be method specific to prevent misclassification of albumin status in patients. Change in albumin methodology may have significant impact on hospital resources. © The Author(s) 2015.

  17. External RNA Controls Consortium Beta Version Update.

    PubMed

    Lee, Hangnoh; Pine, P Scott; McDaniel, Jennifer; Salit, Marc; Oliver, Brian

    2016-01-01

    Spike-in RNAs are valuable controls for a variety of gene expression measurements. The External RNA Controls Consortium developed test sets that were used in a number of published reports. Here we provide an authoritative table that summarizes, updates, and corrects errors in the test version that ultimately resulted in the certified Standard Reference Material 2374. We have noted existence of anti-sense RNA controls in the material, corrected sub-pool memberships, and commented on control RNAs that displayed inconsistent behavior.

  18. Follow-Up of External Quality Controls for PCR-Based Diagnosis of Whooping Cough in a Hospital Laboratory Network (Renacoq) and in Other Hospital and Private Laboratories in France.

    PubMed

    Guillot, Sophie; Guiso, Nicole

    2016-08-01

    The French National Reference Centre (NRC) for Whooping Cough carried out an external quality control (QC) analysis in 2010 for the PCR diagnosis of whooping cough. The main objective of the study was to assess the impact of this QC in the participating laboratories through a repeat analysis in 2012. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  19. [Neurotransmitter mechanisms of context-dependent behavior].

    PubMed

    D'iakonova, V E

    2012-01-01

    The influence of context on behavioral choice is well known. Context can refer to behavioral state of an animal and to external factors such as season, presence of other individuals or food availability. How external and internal factors influencing decision-making are translated at the cellular level? I review the recent neuroethological data that strongly suggest that context reflects in content of neuroactive substances (neurotransmitters, modulators, hormones) that present in the extraneuronal milieu, while heterochemical neuronal microenvironment in its turn impacts motor program selection.

  20. Primary Synovial Sarcoma of External Auditory Canal: A Case Report.

    PubMed

    Devi, Aarani; Jayakumar, Krishnannair L L

    2017-07-20

    Synovial sarcoma is a rare malignant tumor of mesenchymal origin. Primary synovial sarcoma of the ear is extremely rare and to date only two cases have been published in English medical literature. Though the tumor is reported to have an aggressive nature, early diagnosis and treatment may improve the outcome. Here, we report a rare case of synovial sarcoma of the external auditory canal in an 18-year-old male who was managed by chemotherapy and referred for palliation due to tumor progression.

  1. Validity of the Externalizing Spectrum Inventory in a Criminal Offender Sample: Relations with Disinhibitory Psychopathology, Personality, and Psychopathic Features

    PubMed Central

    Venables, Noah C.; Patrick, Christopher J.

    2013-01-01

    The Externalizing Spectrum Inventory (ESI; Krueger, Markon, Patrick, Benning, & Kramer, 2007) provides a self-report based method for indexing a range of correlated problem behaviors and traits in the domain of deficient impulse control. The ESI organizes lower-order behaviors and traits of this kind around higher-order factors encompassing general disinhibitory proneness, callous-aggression, and substance abuse. The current study used data from a male prisoner sample (N = 235) to evaluate the validity of ESI total and factor scores in relation to external criterion measures consisting of externalizing disorder symptoms (including child and adult antisocial deviance and substance-related problems) assessed via diagnostic interview, personality traits assessed by self-report, and psychopathic features as assessed by both interview and self-report. Results provide evidence for the validity of the ESI measurement model and point to its potential utility as a referent for research on the neurobiological correlates and etiological bases of externalizing proneness. PMID:21787091

  2. Validity of the Externalizing Spectrum Inventory in a criminal offender sample: relations with disinhibitory psychopathology, personality, and psychopathic features.

    PubMed

    Venables, Noah C; Patrick, Christopher J

    2012-03-01

    The Externalizing Spectrum Inventory (ESI; Krueger, Markon, Patrick, Benning, & Kramer, 2007) provides a self-report based method for indexing a range of correlated problem behaviors and traits in the domain of deficient impulse control. The ESI organizes lower order behaviors and traits of this kind around higher order factors encompassing general disinhibitory proneness, callous-aggression, and substance abuse. In the current study, we used data from a male prisoner sample (N = 235) to evaluate the validity of ESI total and factor scores in relation to external criterion measures consisting of externalizing disorder symptoms (including child and adult antisocial deviance and substance-related problems) assessed via diagnostic interviews, personality traits assessed with self-reports, and psychopathic features as assessed with both interviews and self-reports. Results provide evidence for the validity of the ESI measurement model and point to its potential usefulness as a referent for research on the neurobiological correlates and etiological bases of externalizing proneness.

  3. Genetics Home Reference: Czech dysplasia

    MedlinePlus

    ... for making a protein that forms type II collagen. This type of collagen is found mostly in the clear gel that ... in the nose and external ears. Type II collagen is essential for the normal development of bones ...

  4. Genetics Home Reference: Kniest dysplasia

    MedlinePlus

    ... for making a protein that forms type II collagen. This type of collagen is found mostly in the clear gel that ... in the nose and external ears. Type II collagen is essential for the normal development of bones ...

  5. Genetics Home Reference: hypochondrogenesis

    MedlinePlus

    ... for making a protein that forms type II collagen. This type of collagen is found mostly in the clear gel that ... in the nose and external ears. Type II collagen is essential for the normal development of bones ...

  6. DREISS: Using State-Space Models to Infer the Dynamics of Gene Expression Driven by External and Internal Regulatory Networks.

    PubMed

    Wang, Daifeng; He, Fei; Maslov, Sergei; Gerstein, Mark

    2016-10-01

    Gene expression is controlled by the combinatorial effects of regulatory factors from different biological subsystems such as general transcription factors (TFs), cellular growth factors and microRNAs. A subsystem's gene expression may be controlled by its internal regulatory factors, exclusively, or by external subsystems, or by both. It is thus useful to distinguish the degree to which a subsystem is regulated internally or externally-e.g., how non-conserved, species-specific TFs affect the expression of conserved, cross-species genes during evolution. We developed a computational method (DREISS, dreiss.gerteinlab.org) for analyzing the Dynamics of gene expression driven by Regulatory networks, both External and Internal based on State Space models. Given a subsystem, the "state" and "control" in the model refer to its own (internal) and another subsystem's (external) gene expression levels. The state at a given time is determined by the state and control at a previous time. Because typical time-series data do not have enough samples to fully estimate the model's parameters, DREISS uses dimensionality reduction, and identifies canonical temporal expression trajectories (e.g., degradation, growth and oscillation) representing the regulatory effects emanating from various subsystems. To demonstrate capabilities of DREISS, we study the regulatory effects of evolutionarily conserved vs. divergent TFs across distant species. In particular, we applied DREISS to the time-series gene expression datasets of C. elegans and D. melanogaster during their embryonic development. We analyzed the expression dynamics of the conserved, orthologous genes (orthologs), seeing the degree to which these can be accounted for by orthologous (internal) versus species-specific (external) TFs. We found that between two species, the orthologs have matched, internally driven expression patterns but very different externally driven ones. This is particularly true for genes with evolutionarily ancient functions (e.g. the ribosomal proteins), in contrast to those with more recently evolved functions (e.g., cell-cell communication). This suggests that despite striking morphological differences, some fundamental embryonic-developmental processes are still controlled by ancient regulatory systems.

  7. Patterning in systems driven by nonlocal external forces.

    PubMed

    Luneville, L; Mallick, K; Pontikis, V; Simeone, D

    2016-11-01

    This work focuses on systems displaying domain patterns resulting from competing external and internal dynamics. To this end, we introduce a Lyapunov functional capable of describing the steady states of systems subject to external forces, by adding nonlocal terms to the Landau Ginzburg free energy of the system. Thereby, we extend the existing methodology treating long-range order interactions, to the case of external nonlocal forces. By studying the quadratic term of this Lyapunov functional, we compute the phase diagram in the temperature versus external field and we determine all possible modulated phases (domain patterns) as a function of the external forces and the temperature. Finally, we investigate patterning in chemical reactive mixtures and binary mixtures under irradiation, and we show that the last case opens the path toward micro-structural engineering of materials.

  8. Patterning in systems driven by nonlocal external forces

    NASA Astrophysics Data System (ADS)

    Luneville, L.; Mallick, K.; Pontikis, V.; Simeone, D.

    2016-11-01

    This work focuses on systems displaying domain patterns resulting from competing external and internal dynamics. To this end, we introduce a Lyapunov functional capable of describing the steady states of systems subject to external forces, by adding nonlocal terms to the Landau Ginzburg free energy of the system. Thereby, we extend the existing methodology treating long-range order interactions, to the case of external nonlocal forces. By studying the quadratic term of this Lyapunov functional, we compute the phase diagram in the temperature versus external field and we determine all possible modulated phases (domain patterns) as a function of the external forces and the temperature. Finally, we investigate patterning in chemical reactive mixtures and binary mixtures under irradiation, and we show that the last case opens the path toward micro-structural engineering of materials.

  9. Ab initio calculation of proton-coupled electron transfer rates using the external-potential representation: A ubiquinol complex in solution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yamamoto, Takeshi; Kato, Shigeki

    2007-06-14

    In quantum-mechanical/molecular-mechanical (QM/MM) treatment of chemical reactions in condensed phases, one solves the electronic Schroedinger equation for the solute (or an active site) under the electrostatic field from the environment. This Schroedinger equation depends parametrically on the solute nuclear coordinates R and the external electrostatic potential V. This fact suggests that one may use R and V as natural collective coordinates for describing the entire system, where V plays the role of collective solvent variables. In this paper such an (R,V) representation of the QM/MM canonical ensemble is described, with particular focus on how to treat charge transfer processes inmore » this representation. As an example, the above method is applied to the proton-coupled electron transfer of a ubiquinol analog with phenoxyl radical in acetonitrile solvent. Ab initio free-energy surfaces are calculated as functions of R and V using the reference interaction site model self-consistent field method, the equilibrium points and the minimum free-energy crossing point are located in the (R,V) space, and then the kinetic isotope effects (KIEs) are evaluated approximately. The results suggest that a stiffer proton potential at the transition state may be responsible for unusual KIEs observed experimentally for related systems.« less

  10. UDE-based control of variable-speed wind turbine systems

    NASA Astrophysics Data System (ADS)

    Ren, Beibei; Wang, Yeqin; Zhong, Qing-Chang

    2017-01-01

    In this paper, the control of a PMSG (permanent magnet synchronous generator)-based variable-speed wind turbine system with a back-to-back converter is considered. The uncertainty and disturbance estimator (UDE)-based control approach is applied to the regulation of the DC-link voltage and the control of the RSC (rotor-side converter) and the GSC (grid-side converter). For the rotor-side controller, the UDE-based vector control is developed for the RSC with PMSG control to facilitate the application of the MPPT (maximum power point tracking) algorithm for the maximum wind energy capture. For the grid-side controller, the UDE-based vector control is developed to control the GSC with the power reference generated by a UDE-based DC-link voltage controller. Compared with the conventional vector control, the UDE-based vector control can achieve reliable current decoupling control with fast response. Moreover, the UDE-based DC-link voltage regulation can achieve stable DC-link voltage under model uncertainties and external disturbances, e.g. wind speed variations. The effectiveness of the proposed UDE-based control approach is demonstrated through extensive simulation studies in the presence of coupled dynamics, model uncertainties and external disturbances under varying wind speeds. The UDE-based control is able to generate more energy, e.g. by 5% for the wind profile tested.

  11. Development of a real-time internal and external marker tracking system for particle therapy: a phantom study using patient tumor trajectory data.

    PubMed

    Cho, Junsang; Cheon, Wonjoong; Ahn, Sanghee; Jung, Hyunuk; Sheen, Heesoon; Park, Hee Chul; Han, Youngyih

    2017-09-01

    Target motion-induced uncertainty in particle therapy is more complicated than that in X-ray therapy, requiring more accurate motion management. Therefore, a hybrid motion-tracking system that can track internal tumor motion and as well as an external surrogate of tumor motion was developed. Recently, many correlation tests between internal and external markers in X-ray therapy have been developed; however, the accuracy of such internal/external marker tracking systems, especially in particle therapy, has not yet been sufficiently tested. In this article, the process of installing an in-house hybrid internal/external motion-tracking system is described and the accuracy level of tracking system was acquired. Our results demonstrated that the developed in-house external/internal combined tracking system has submillimeter accuracy, and can be clinically used as a particle therapy system as well as a simulation system for moving tumor treatment. © The Author 2017. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology.

  12. Intraoperative Localization of Tantalum Markers for Proton Beam Radiation of Choroidal Melanoma by an Opto-Electronic Navigation System: A Novel Technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Amstutz, Christoph A., E-mail: christoph.amstutz@usz.ch; Bechrakis, Nikolaos E.; Foerster, Michael H.

    2012-03-15

    Purpose: External beam proton radiation therapy has been used since 1975 to treat choroidal melanoma. For tumor location determination during proton radiation treatment, surgical tantalum clips are registered with image data. This report introduces the intraoperative application of an opto-electronic navigation system to determine with high precision the position of the tantalum markers and their spatial relationship to the tumor and anatomical landmarks. The application of the technique in the first 4 patients is described. Methods and Materials: A navigated reference base was attached noninvasively to the eye, and a navigated pointer device was used to record the spatial positionmore » of the tantalum markers, the tumor, and anatomical landmarks. Measurement accuracy was assessed on ex vivo porcine eye specimen by repetitive recording of the tantalum marker positions. The method was applied intraoperatively on 4 patients undergoing routine tantalum clip surgery. The spatial position information delivered by the navigation system was compared to the geometric data generated by the EYEPLAN software. Results: In the ex vivo experiments, the maximum repetition error was 0.34 mm. For the intraoperative application, the root mean square error of paired-points matching of the marker positions from the navigation system and from the EYEPLAN software was 0.701-1.25 mm. Conclusions: Navigation systems are a feasible tool for accurate localization of tantalum markers and anatomic landmarks. They can provide additional geometric information, and therefore have the potential to increase the reliability and accuracy of external beam proton radiation therapy for choroidal melanoma.« less

  13. An Adaptive Low-Cost GNSS/MEMS-IMU Tightly-Coupled Integration System with Aiding Measurement in a GNSS Signal-Challenged Environment

    PubMed Central

    Zhou, Qifan; Zhang, Hai; Li, You; Li, Zheng

    2015-01-01

    The main aim of this paper is to develop a low-cost GNSS/MEMS-IMU tightly-coupled integration system with aiding information that can provide reliable position solutions when the GNSS signal is challenged such that less than four satellites are visible in a harsh environment. To achieve this goal, we introduce an adaptive tightly-coupled integration system with height and heading aiding (ATCA). This approach adopts a novel redundant measurement noise estimation method for an adaptive Kalman filter application and also augments external measurements in the filter to aid the position solutions, as well as uses different filters to deal with various situations. On the one hand, the adaptive Kalman filter makes use of the redundant measurement system’s difference sequence to estimate and tune noise variance instead of employing a traditional innovation sequence to avoid coupling with the state vector error. On the other hand, this method uses the external height and heading angle as auxiliary references and establishes a model for the measurement equation in the filter. In the meantime, it also changes the effective filter online based on the number of tracked satellites. These measures have increasingly enhanced the position constraints and the system observability, improved the computational efficiency and have led to a good result. Both simulated and practical experiments have been carried out, and the results demonstrate that the proposed method is effective at limiting the system errors when there are less than four visible satellites, providing a satisfactory navigation solution. PMID:26393605

  14. A Direct Georeferencing Method for Terrestrial Laser Scanning Using GNSS Data and the Vertical Deflection from Global Earth Gravity Models

    PubMed Central

    Borkowski, Andrzej; Owczarek-Wesołowska, Magdalena; Gromczak, Anna

    2017-01-01

    Terrestrial laser scanning is an efficient technique in providing highly accurate point clouds for various geoscience applications. The point clouds have to be transformed to a well-defined reference frame, such as the global Geodetic Reference System 1980. The transformation to the geocentric coordinate frame is based on estimating seven Helmert parameters using several GNSS (Global Navigation Satellite System) referencing points. This paper proposes a method for direct point cloud georeferencing that provides coordinates in the geocentric frame. The proposed method employs the vertical deflection from an external global Earth gravity model and thus demands a minimum number of GNSS measurements. The proposed method can be helpful when the number of georeferencing GNSS points is limited, for instance in city corridors. It needs only two georeferencing points. The validation of the method in a field test reveals that the differences between the classical georefencing and the proposed method amount at maximum to 7 mm with the standard deviation of 8 mm for all of three coordinate components. The proposed method may serve as an alternative for the laser scanning data georeferencing, especially when the number of GNSS points is insufficient for classical methods. PMID:28672795

  15. On the geometrically nonlinear elastic response of class θ = 1 tensegrity prisms

    NASA Astrophysics Data System (ADS)

    Mascolo, Ida; Amendola, Ada; Zuccaro, Giulio; Feo, Luciano; Fraternali, Fernando

    2018-03-01

    The present work studies the geometrically nonlinear response of class ϑ=1 tensegrity prisms modeled as a collection of elastic springs reacting in tension (strings or cables) or compression (bars), under uniform uniaxial loading. The incremental equilibrium equations of the structure are numerically solved through a path-following procedure, with the aim of modeling the mechanical behavior of the structure in the large displacement regime. Several numerical results are presented with reference to a variety of physical models, which use two different materials for the cables and the bars, and show different aspect ratios associated with either 'standard' or 'expanded' configurations. An experimental validation of the predicted constitutive response is conducted with reference to a 'thick' and a 'slender' model, observing rather good theory vs. experiment matching. The given numerical and experimental results highlight that the elastic response of the examined structures may switch from stiffening to softening, depending on the geometry of the system, the magnitude of the external load, and the applied prestress. The outcomes of the current study confirm previous literature results on the elastic response of minimal tensegrity prisms, and pave the way to the use of tensegrity systems as nonlinear spring units forming tunable mechanical metamaterials.

  16. A Direct Georeferencing Method for Terrestrial Laser Scanning Using GNSS Data and the Vertical Deflection from Global Earth Gravity Models.

    PubMed

    Osada, Edward; Sośnica, Krzysztof; Borkowski, Andrzej; Owczarek-Wesołowska, Magdalena; Gromczak, Anna

    2017-06-24

    Terrestrial laser scanning is an efficient technique in providing highly accurate point clouds for various geoscience applications. The point clouds have to be transformed to a well-defined reference frame, such as the global Geodetic Reference System 1980. The transformation to the geocentric coordinate frame is based on estimating seven Helmert parameters using several GNSS (Global Navigation Satellite System) referencing points. This paper proposes a method for direct point cloud georeferencing that provides coordinates in the geocentric frame. The proposed method employs the vertical deflection from an external global Earth gravity model and thus demands a minimum number of GNSS measurements. The proposed method can be helpful when the number of georeferencing GNSS points is limited, for instance in city corridors. It needs only two georeferencing points. The validation of the method in a field test reveals that the differences between the classical georefencing and the proposed method amount at maximum to 7 mm with the standard deviation of 8 mm for all of three coordinate components. The proposed method may serve as an alternative for the laser scanning data georeferencing, especially when the number of GNSS points is insufficient for classical methods.

  17. Can Newton's Third Law Be "Derived" from the Second?

    NASA Astrophysics Data System (ADS)

    Gangopadhyaya, Asim; Harrington, James

    2017-04-01

    Newton's laws have engendered much discussion over several centuries. Today, the internet is awash with a plethora of information on this topic. We find many references to Newton's laws, often discussions of various types of misunderstandings and ways to explain them. Here we present an intriguing example that shows an assumption hidden in Newton's third law that is often overlooked. As is well known, the first law defines an inertial frame of reference and the second law determines the acceleration of a particle in such a frame due to an external force. The third law describes forces exerted on each other in a two-particle system, and allows us to extend the second law to a system of particles. Students are often taught that the three laws are independent. Here we present an example that challenges this assumption. At first glance, it seems to show that, at least for a special case, the third law follows from the second law. However, a careful examination of the assumptions demonstrates that is not quite the case. Ultimately, the example does illustrate the significance of the concept of mass in linking Newton's dynamical principles.

  18. Space Shuttle with rail system and aft thrust structure securing solid rocket boosters to external tank

    NASA Technical Reports Server (NTRS)

    Vonpragenau, G. L. (Inventor)

    1984-01-01

    The configuration and relationship of the external propellant tank and solid rocket boosters of space transportation systems such as the space shuttle are described. The space shuttle system with the improved propellant tank is shown. The external tank has a forward pressure vessel for liquid hydrogen and an aft pressure vessel for liquid oxygen. The solid rocket boosters are joined together by a thrust frame which extends across and behind the external tank. The thrust of the orbiter's main rocket engines are transmitted to the aft portion of the external tank and the thrust of the solid rocket boosters are transmitted to the aft end of the external tank.

  19. Next Generation Trusted Radiation Identification System (NG-TRIS).

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Flynn, Adam J.; Amai, Wendy A.; Merkle, Peter Benedict

    2010-05-01

    The original Trusted Radiation Identification System (TRIS) was developed from 1999-2001, featuring information barrier technology to collect gamma radiation template measurements useful for arms control regime operations. The first TRIS design relied upon a multichannel analyzer (MCA) that was external to the protected volume of the system enclosure, undesirable from a system security perspective. An internal complex programmable logic device (CPLD) contained data which was not subject to software authentication. Physical authentication of the TRIS instrument case was performed by a sensitive but slow eddy-current inspection method. This paper describes progress to date for the Next Generation TRIS (NG-TRIS), whichmore » improves the TRIS design. We have incorporated the MCA internal to the trusted system volume, achieved full authentication of CPLD data, and have devised rapid methods to authenticate the system enclosure and weld seals of the NG-TRIS enclosure. For a complete discussion of the TRIS system and components upon which NG-TRIS is based, the reader is directed to the comprehensive user's manual and system reference of Seager, et al.« less

  20. Testing Method for External Cladding Systems - Incerc Romania

    NASA Astrophysics Data System (ADS)

    Simion, A.; Dragne, H.

    2017-06-01

    This research presents a new testing method in a natural scale for external cladding systems tested on buildings with minimum than 3 floors [1]. The testing method is unique in Romania and it is similar about many fire testing current methods from European Union states. Also, presents the fire propagation and the effect of fire smoke on the building façade composed of thermal insulation. Laboratory of testing and research for building fire safety from National Institute INCERC Bucharest, provides a test method for determining the fire performance characteristics of non-loadbearing external cladding systems and external wall insulation systems when applied to the face of a building and exposed to an external fire under controlled conditions [2]. The fire exposure is representative of an external fire source or a fully-developed (post-flashover) fire in a room, venting through an opening such as a window aperture that exposes the cladding to the effects of external flames, or an external fire source. On the future, fire tests will be experimented for answer demande a number of high-profile fires where the external facade of tall buildings provided a route for vertical fire spread.

  1. GCR Simulator Reference Field and a Spectral Approach for Laboratory Simulation

    NASA Technical Reports Server (NTRS)

    Slaba, Tony C.; Blattnig, Steve R.; Norbury, John W.; Rusek, Adam; La Tessa, Chiara; Walker, Steven A.

    2015-01-01

    The galactic cosmic ray (GCR) simulator at the NASA Space Radiation Laboratory (NSRL) is intended to deliver the broad spectrum of particles and energies encountered in deep space to biological targets in a controlled laboratory setting. In this work, certain aspects of simulating the GCR environment in the laboratory are discussed. Reference field specification and beam selection strategies at NSRL are the main focus, but the analysis presented herein may be modified for other facilities. First, comparisons are made between direct simulation of the external, free space GCR field and simulation of the induced tissue field behind shielding. It is found that upper energy constraints at NSRL limit the ability to simulate the external, free space field directly (i.e. shielding placed in the beam line in front of a biological target and exposed to a free space spectrum). Second, variation in the induced tissue field associated with shielding configuration and solar activity is addressed. It is found that the observed variation is likely within the uncertainty associated with representing any GCR reference field with discrete ion beams in the laboratory, given current facility constraints. A single reference field for deep space missions is subsequently identified. Third, an approach for selecting beams at NSRL to simulate the designated reference field is presented. Drawbacks of the proposed methodology are discussed and weighed against alternative simulation strategies. The neutron component and track structure characteristics of the simulated field are discussed in this context.

  2. Changing Systems of External Examination

    ERIC Educational Resources Information Center

    Stensaker, Bjorn; Brandt, Ellen; Solum, Nils Henrik

    2008-01-01

    Purpose: The purpose of this paper is to review and identify changes in systems of external examinations in Denmark, the UK and Norway. Design/methodology/approach: Comparative analysis of studies, reviews and documents concerning the purpose and functioning of systems of external examination in three selected countries. Findings: The paper…

  3. Sol-Gel Deposition of Iridium Oxide for Biomedical Micro-Devices

    PubMed Central

    Nguyen, Cuong M.; Rao, Smitha; Yang, Xuesong; Dubey, Souvik; Mays, Jeffrey; Cao, Hung; Chiao, Jung-Chih

    2015-01-01

    Flexible iridium oxide (IrOx)-based micro-electrodes were fabricated on flexible polyimide substrates using a sol-gel deposition process for utilization as integrated pseudo-reference electrodes for bio-electrochemical sensing applications. The fabrication method yields reliable miniature on-probe IrOx electrodes with long lifetime, high stability and repeatability. Such sensors can be used for long-term measurements. Various dimensions of sol-gel iridium oxide electrodes including 1 mm × 1 mm, 500 μm × 500 μm, and 100 μm × 100 μm were fabricated. Sensor longevity and pH dependence were investigated by immersing the electrodes in hydrochloric acid, fetal bovine serum (FBS), and sodium hydroxide solutions for 30 days. Less pH dependent responses, compared to IrOx electrodes fabricated by electrochemical deposition processes, were measured at 58.8 ± 0.4 mV/pH, 53.8 ± 1.3 mV/pH and 48 ± 0.6 mV/pH, respectively. The on-probe IrOx pseudo-reference electrodes were utilized for dopamine sensing. The baseline responses of the sensors were higher than the one using an external Ag/AgCl reference electrode. Using IrOx reference electrodes integrated on the same probe with working electrodes eliminated the use of cytotoxic Ag/AgCl reference electrode without loss in sensitivity. This enables employing such sensors in long-term recording of concentrations of neurotransmitters in central nervous systems of animals and humans. PMID:25686309

  4. Classroom Environment in the Implementation of an Innovative Curriculum Project in Science Education.

    ERIC Educational Resources Information Center

    Suarez, Mercedes; Pias, Rosa; Membiela, Pedro; Dapia, Dolores

    1998-01-01

    Analyzes the perceptions of students, teachers, and external observers in order to study the influence of classroom environment on the implementation of an innovative project in science education. Contains 33 references. (DDR)

  5. What is Quantum Mechanics? A Minimal Formulation

    NASA Astrophysics Data System (ADS)

    Friedberg, R.; Hohenberg, P. C.

    2018-03-01

    This paper presents a minimal formulation of nonrelativistic quantum mechanics, by which is meant a formulation which describes the theory in a succinct, self-contained, clear, unambiguous and of course correct manner. The bulk of the presentation is the so-called "microscopic theory", applicable to any closed system S of arbitrary size N, using concepts referring to S alone, without resort to external apparatus or external agents. An example of a similar minimal microscopic theory is the standard formulation of classical mechanics, which serves as the template for a minimal quantum theory. The only substantive assumption required is the replacement of the classical Euclidean phase space by Hilbert space in the quantum case, with the attendant all-important phenomenon of quantum incompatibility. Two fundamental theorems of Hilbert space, the Kochen-Specker-Bell theorem and Gleason's theorem, then lead inevitably to the well-known Born probability rule. For both classical and quantum mechanics, questions of physical implementation and experimental verification of the predictions of the theories are the domain of the macroscopic theory, which is argued to be a special case or application of the more general microscopic theory.

  6. From action intentions to action effects: how does the sense of agency come about?

    PubMed Central

    Chambon, Valérian; Sidarus, Nura; Haggard, Patrick

    2014-01-01

    Sense of agency refers to the feeling of controlling an external event through one’s own action. On one influential view, agency depends on how predictable the consequences of one’s action are, getting stronger as the match between predicted and actual effect of an action gets closer. Thus, sense of agency arises when external events that follow our action are consistent with predictions of action effects made by the motor system while we perform or simply intend to perform an action. According to this view, agency is inferred retrospectively, after an action has been performed and its consequences are known. In contrast, little is known about whether and how internal processes involved in the selection of actions may influence subjective sense of control, in advance of the action itself, and irrespective of effect predictability. In this article, we review several classes of behavioral and neuroimaging data suggesting that earlier processes, linked to fluency of action selection, prospectively contribute to sense of agency. These findings have important implications for better understanding human volition and abnormalities of action experience. PMID:24860486

  7. Irreversibilities and efficiency at maximum power of heat engines: the illustrative case of a thermoelectric generator.

    PubMed

    Apertet, Y; Ouerdane, H; Goupil, C; Lecoeur, Ph

    2012-03-01

    Energy conversion efficiency at maximum output power, which embodies the essential characteristics of heat engines, is the main focus of the present work. The so-called Curzon and Ahlborn efficiency η(CA) is commonly believed to be an absolute reference for real heat engines; however, a different but general expression for the case of stochastic heat engines, η(SS), was recently found and then extended to low-dissipation engines. The discrepancy between η(CA) and η(SS) is here analyzed considering different irreversibility sources of heat engines, of both internal and external types. To this end, we choose a thermoelectric generator operating in the strong-coupling regime as a physical system to qualitatively and quantitatively study the impact of the nature of irreversibility on the efficiency at maximum output power. In the limit of pure external dissipation, we obtain η(CA), while η(SS) corresponds to the case of pure internal dissipation. A continuous transition between from one extreme to the other, which may be operated by tuning the different sources of irreversibility, also is evidenced.

  8. DNA damage and external lesions in brown bullheads (Ameiurus nebulosus) from contaminated habitats

    USGS Publications Warehouse

    Yang, X.; Meier, J.; Chang, L.; Rowan, M.; Baumann, P.C.

    2006-01-01

    The Comet assay was used to compare levels of DNA damage in brown bullheads (Ameiurus nebulosus) collected from three known contaminated locations, the Cuyahoga River (OH, USA), Ashtabula River (OH, USA; both tributaries to Lake Erie, USA), and Ashumet Pond (Cape Cod, MA, USA), with brown bullheads collected from three paired reference sites, Old Woman Creek (OH, USA), Conneaut River (OH, USA; both tributaries to Lake Erie), and Great Herring Pond (mainland MA, USA), respectively. Blood was sampled from each fish, and the Comet assay was conducted on erythrocytes. The assay results demonstrate that fish from the three contaminated sites each suffered higher DNA damage compared with fish from their respective reference sites. The results also show that the genetic damage was associated with the occurrence of external lesions and deformities in fish. The Comet assay is sufficiently sensitive to detect exposure of natural fish populations to environmental levels of genotoxic contaminants. ?? 2006 SETAC.

  9. Injury to the male external genitalia: a comprehensive review.

    PubMed

    Furr, James; Culkin, Daniel

    2017-04-01

    While rare, trauma and injury to the male external genitalia can result in significant consequences regarding function, appearance, psychological effects, and overall quality of life. Due to the relative paucity of literature regarding male external genitalia injuries, few standardized protocols exist. This review aims to outline common clinical causes of male external genitalia injuries by both anatomic location and etiology. Initial stabilization, long-term reconstruction, and coverage options are discussed in detail. Outcomes of complex grafts have favorable success rates of 90-100% in the hands of experienced surgeons. Outcomes of penile, testicular trauma also have favorable outcomes when managed appropriately. Attempts at reconstruction after initial injury stabilization should be undertaken at high-volume centers where a multidisciplinary approach can be employed. This manuscript will be an excellent reference and source that can provide direction for evaluation and management of these complex presentations.

  10. Effectiveness of external inspection of compliance with standards in improving healthcare organisation behaviour, healthcare professional behaviour or patient outcomes

    PubMed Central

    Flodgren, Gerd; Pomey, Marie-Pascale; Taber, Sarah A; Eccles, Martin P

    2014-01-01

    Background Inspection systems are used in health care to promote quality improvements, i.e. to achieve changes in organisational structures or processes, healthcare provider behaviour and patient outcomes. These systems are based on the assumption that externally promoted adherence to evidence-based standards (through inspection/assessment) will result in higher quality of health care. However, the benefits of external inspection in terms of organisational, provider and patient level outcomes are not clear. Objectives To evaluate the effectiveness of external inspection of compliance with standards in improving healthcare organisation behaviour, healthcare professional behaviour and patient outcomes. Search methods We searched the following electronic databases for studies: the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, EMBASE, CINAHL, Cochrane Database of Systematic Reviews, Database of Abstracts of Reviews of Effectiveness, Scopus, HMIC, Index to Theses and Intute from their inception dates up to May 2011. There was no language restriction and studies were included regardless of publication status. We searched the reference lists of included studies and contacted authors of relevant papers, accreditation bodies and the International Organization for Standardisation (ISO), regarding any further published or unpublished work. Selection criteria We included randomised controlled trials (RCTs), controlled clinical trials (CCTs), interrupted time-series (ITSs) and controlled before and after studies (CBAs) evaluating the effect of external inspection against external standards on healthcare organisation change, healthcare professional behaviour or patient outcomes in hospitals, primary healthcare organisations and other community-based healthcare organisations. Data collection and analysis Two review authors independently applied eligibility criteria, extracted data and assessed the risk of bias of each included study. Since meta-analysis was not possible, we produced a narrative results summary. Main results We identified one cluster-RCT involving 20 South African public hospitals (Salmon 2003) and one ITS involving all acute trusts in England (OPM 2009) for inclusion in this review. Salmon and colleagues (Salmon 2003) showed mixed effects of a hospital accreditation system on the compliance with COHSASA (the Council for Health Services Accreditation for South Africa) accreditation standards and eight indicators of hospital quality. Significantly improved total mean compliance score with COHSASA accreditation standards was found for 21/28 service elements: mean intervention effect (95% confidence interval (CI)) was 30% (23% to 57%) (P < 0.001). The score increased from 48% to 78% in intervention hospitals, while remaining the same in control hospitals (43%). A sub-analysis of 424 a priori identified critical criteria (19 service elements) showed significantly improved compliance with the critical standards (P < 0.001). The score increased from 41% (21% to 46%) to 75% (55% to 96%) in intervention hospitals, but was unchanged in control hospitals (37%). Only one of the nine intervention hospitals gained full accreditation status at the end of the study period, with two others reached pre-accreditation status.The median intervention effect (range) for the indicators of hospital quality of care was 2.4 (−1.9 to +11.8) and only one of the eight indicators: ‘nurses perception of clinical quality, participation and teamwork’ was significantly improved (mean intervention effect 5.7, P = 0.03). Re-analysis of the MRSA (methicillin-resistant Staphylococcus aureus) data showed statistically non-significant effects of the Healthcare Commissions Infection Inspection programme. Authors’ conclusions We only identified two studies for inclusion in this review, which highlights the paucity of high-quality controlled evaluations of the effectiveness of external inspection systems. No firm conclusions could therefore be drawn about the effectiveness of external inspection on compliance with standards. PMID:22071861

  11. Phosphorus acquisition efficiency in arbuscular mycorrhizal maize is correlated with the abundance of root-external hyphae and the accumulation of transcripts encoding PHT1 phosphate transporters.

    PubMed

    Sawers, Ruairidh J H; Svane, Simon F; Quan, Clement; Grønlund, Mette; Wozniak, Barbara; Gebreselassie, Mesfin-Nigussie; González-Muñoz, Eliécer; Chávez Montes, Ricardo A; Baxter, Ivan; Goudet, Jerome; Jakobsen, Iver; Paszkowski, Uta

    2017-04-01

    Plant interactions with arbuscular mycorrhizal fungi have long attracted interest for their potential to promote more efficient use of mineral resources in agriculture. Their use, however, remains limited by a lack of understanding of the processes that determine the outcome of the symbiosis. In this study, the impact of host genotype on growth response to mycorrhizal inoculation was investigated in a panel of diverse maize lines. A panel of 30 maize lines was evaluated with and without inoculation with arbuscular mycorrhizal fungi. The line Oh43 was identified to show superior response and, along with five other reference lines, was characterized in greater detail in a split-compartment system, using 33 P to quantify mycorrhizal phosphorus uptake. Changes in relative growth indicated variation in host capacity to profit from the symbiosis. Shoot phosphate content, abundance of root-internal and -external fungal structures, mycorrhizal phosphorus uptake, and accumulation of transcripts encoding plant PHT1 family phosphate transporters varied among lines. Superior response in Oh43 is correlated with extensive development of root-external hyphae, accumulation of specific Pht1 transcripts and high phosphorus uptake by mycorrhizal plants. The data indicate that host genetic factors influence fungal growth strategy with an impact on plant performance. © 2017 The Authors. New Phytologist © 2017 New Phytologist Trust.

  12. Managing facility risk: external threats and health care organizations.

    PubMed

    Reid, Daniel J; Reid, William H

    2014-01-01

    Clinicians and clinical administrators should have a basic understanding of physical and financial risk to mental health facilities related to external physical threat, including actions usually viewed as "terrorism" and much more common sources of violence. This article refers to threats from mentally ill persons and those acting out of bizarre or misguided "revenge," extortionists and other outright criminals, and perpetrators usually identified as domestic or international terrorists. The principles apply both to relatively small and contained acts (such as a patient or ex-patient attacking a staff member) and to much larger events (such as bombings and armed attack), and are relevant to facilities both within and outside the U.S. Patient care and accessibility to mental health services rest not only on clinical skills, but also on a place to practice them and an organized system supported by staff, physical facilities, and funding. Clinicians who have some familiarity with the non-clinical requirements for care are in a position to support non-clinical staff in preventing care from being interrupted by external threats or events such as terrorist activity, and/or to serve at the interface of facility operations and direct clinical care. Readers should note that this article is an introduction to the topic and cannot address all local, state and national standards for hospital safety, or insurance providers' individual facility requirements. Copyright © 2014 John Wiley & Sons, Ltd.

  13. Sustainable interprofessional teamwork needs a team-friendly healthcare system: Experiences from a collaborative Dutch programme.

    PubMed

    van Dijk-de Vries, Anneke; van Dongen, Jerôme Jean Jacques; van Bokhoven, Marloes Amantia

    2017-03-01

    The significance of effective interprofessional teamwork to improve the quality of care has been widely recognised. Effective interprofessional teamwork calls on good collaboration between professionals and patients, coordination between professionals, and the development of teamwork over time. Effective development of teams also requires support from the wider organisational context. In a Dutch village, healthcare professionals work closely together, and mutual consultations as well as interprofessional meetings take place on a regular basis. The network was created as a precondition for sustainable interprofessional teamwork in elderly care. However, several external barriers were experienced regarding the supportive structure and cooperative attitude of the healthcare insurer and municipality. The aim of the article is to examine these experience-based issues regarding internal organisation, perspective, and definition of effective teamwork. Complicating factors refer to finding the right key figures, and the different perspectives on team development and team effectiveness. Our conclusion is that the organisation of healthcare insurance companies needs to implement fundamental changes to facilitate an interprofessional care approach. Furthermore, municipalities should work on their vision of the needs and benefits of a fruitful collaboration with interprofessional healthcare teams. The challenge for healthcare teams is to learn to speak the language of external partners. To support the development of interprofessional teams, external parties need to recognise and trust in a shared aim to provide quality of care in an efficient and effective way.

  14. Unintended adverse consequences of a clinical decision support system: two cases.

    PubMed

    Stone, Erin G

    2018-05-01

    Many institutions have implemented clinical decision support systems (CDSSs). While CDSS research papers have focused on benefits of these systems, there is a smaller body of literature showing that CDSSs may also produce unintended adverse consequences (UACs). Detailed here are 2 cases of UACs resulting from a CDSS. Both of these cases were related to external systems that fed data into the CDSS. In the first case, lack of knowledge of data categorization in an external pharmacy system produced a UAC; in the second case, the change of a clinical laboratory instrument produced the UAC. CDSSs rely on data from many external systems. These systems are dynamic and may have changes in hardware, software, vendors, or processes. Such changes can affect the accuracy of CDSSs. These cases point to the need for the CDSS team to be familiar with these external systems. This team (manager and alert builders) should include members in specific clinical specialties with deep knowledge of these external systems.

  15. External Dependencies-Driven Architecture Discovery and Analysis of Implemented Systems

    NASA Technical Reports Server (NTRS)

    Ganesan, Dharmalingam; Lindvall, Mikael; Ron, Monica

    2014-01-01

    A method for architecture discovery and analysis of implemented systems (AIS) is disclosed. The premise of the method is that architecture decisions are inspired and influenced by the external entities that the software system makes use of. Examples of such external entities are COTS components, frameworks, and ultimately even the programming language itself and its libraries. Traces of these architecture decisions can thus be found in the implemented software and is manifested in the way software systems use such external entities. While this fact is often ignored in contemporary reverse engineering methods, the AIS method actively leverages and makes use of the dependencies to external entities as a starting point for the architecture discovery. The AIS method is demonstrated using the NASA's Space Network Access System (SNAS). The results show that, with abundant evidence, the method offers reusable and repeatable guidelines for discovering the architecture and locating potential risks (e.g. low testability, decreased performance) that are hidden deep in the implementation. The analysis is conducted by using external dependencies to identify, classify and review a minimal set of key source code files. Given the benefits of analyzing external dependencies as a way to discover architectures, it is argued that external dependencies deserve to be treated as first-class citizens during reverse engineering. The current structure of a knowledge base of external entities and analysis questions with strategies for getting answers is also discussed.

  16. ISS-CREAM Thermal and Fluid System Design and Analysis

    NASA Technical Reports Server (NTRS)

    Thorpe, Rosemary S.

    2015-01-01

    Thermal and Fluids Analysis Workshop (TFAWS), Silver Spring MD NCTS 21070-15. The ISS-CREAM (Cosmic Ray Energetics And Mass for the International Space Station) payload is being developed by an international team and will provide significant cosmic ray characterization over a long time frame. Cold fluid provided by the ISS Exposed Facility (EF) is the primary means of cooling for 5 science instruments and over 7 electronics boxes. Thermal fluid integrated design and analysis was performed for CREAM using a Thermal Desktop model. This presentation will provide some specific design and modeling examples from the fluid cooling system, complex SCD (Silicon Charge Detector) and calorimeter hardware, and integrated payload and ISS level modeling. Features of Thermal Desktop such as CAD simplification, meshing of complex hardware, External References (Xrefs), and FloCAD modeling will be discussed.

  17. Conduction Electrohydrodynamics with Mobile Electrodes: A Novel Actuation System for Untethered Robots.

    PubMed

    Cacucciolo, Vito; Shigemune, Hiroki; Cianchetti, Matteo; Laschi, Cecilia; Maeda, Shingo

    2017-09-01

    Electrohydrodynamics (EHD) refers to the direct conversion of electrical energy into mechanical energy of a fluid. Through the use of mobile electrodes, this principle is exploited in a novel fashion for designing and testing a millimeter-scale untethered robot, which is powered harvesting the energy from an external electric field. The robot is designed as an inverted sail-boat, with the thrust generated on the sail submerged in the liquid. The diffusion constant of the robot is experimentally computed, proving that its movement is not driven by thermal fluctuations, and then its kinematic and dynamic responses are characterized for different applied voltages. The results show the feasibility of using EHD with mobile electrodes for powering untethered robots and provide new evidences for the further development of this actuation system for both mobile robots and compliant actuators in soft robotics.

  18. The nuclear battery

    NASA Astrophysics Data System (ADS)

    Kozier, K. S.; Rosinger, H. E.

    The evolution and present status of an Atomic Energy of Canada Limited program to develop a small, solid-state, passively cooled reactor power supply known as the Nuclear Battery is reviewed. Key technical features of the Nuclear Battery reactor core include a heat-pipe primary heat transport system, graphite neutron moderator, low-enriched uranium TRISO coated-particle fuel and the use of burnable poisons for long-term reactivity control. An external secondary heat transport system extracts useful heat energy, which may be converted into electricity in an organic Rankine cycle engine or used to produce high-pressure steam. The present reference design is capable of producing about 2400 kW(t) (about 600 kW(e) net) for 15 full-power years. Technical and safety features are described along with recent progress in component hardware development programs and market assessment work.

  19. Space Communication and Navigation SDR Testbed, Overview and Opportunity for Experiments

    NASA Technical Reports Server (NTRS)

    Reinhart, Richard C.

    2013-01-01

    NASA has developed an experimental flight payload (referred to as the Space Communication and Navigation (SCAN) Test Bed) to investigate software defined radio (SDR) communications, networking, and navigation technologies, operationally in the space environment. The payload consists of three software defined radios each compliant to NASAs Space Telecommunications Radio System Architecture, a common software interface description standard for software defined radios. The software defined radios are new technology developments underway by NASA and industry partners launched in 2012. The payload is externally mounted to the International Space Station truss to conduct experiments representative of future mission capability. Experiment operations include in-flight reconfiguration of the SDR waveform functions and payload networking software. The flight system will communicate with NASAs orbiting satellite relay network, the Tracking and Data Relay Satellite System at both S-band and Ka-band and to any Earth-based compatible S-band ground station. The system is available for experiments by industry, academia, and other government agencies to participate in the SDR technology assessments and standards advancements.

  20. Development of NASA's Space Communications and Navigation Test Bed Aboard ISS to Investigate SDR, On-Board Networking and Navigation Technologies

    NASA Technical Reports Server (NTRS)

    Reinhart, Richard C.; Kacpura, Thomas J.; Johnson, Sandra K.; Lux, James P.

    2010-01-01

    NASA is developing an experimental flight payload (referred to as the Space Communication and Navigation (SCAN) Test Bed) to investigate software defined radio (SDR), networking, and navigation technologies, operationally in the space environment. The payload consists of three software defined radios each compliant to NASA s Space Telecommunications Radio System Architecture, a common software interface description standard for software defined radios. The software defined radios are new technology developments underway by NASA and industry partners. Planned for launch in early 2012, the payload will be externally mounted to the International Space Station truss and conduct experiments representative of future mission capability.

  1. Relativity of Scales: Application to AN Endo-Perspective of Temporal Structures

    NASA Astrophysics Data System (ADS)

    Nottale, Laurent; Timar, Pierre

    The theory of scale relativity is an extension of the principle of relativity to scale transformations of the reference system, in a fractal geometry framework where coordinates become explicitly dependent on resolutions. Applied to an observer perspective, it means that the scales of length and of time, usually attributed to the observed object as being intrinsic to it, have actually no existence by themselves, since only the ratio between an external scale and an internal scale, which serves as unit, is meaningful. Oliver Sacks' observations on patients suffering from temporal and spatial distortions in Parkinson's and encephalitis lethargica disease offer a particularly relevant field of application for such a scale-relativistic view.

  2. Stabilization of exact nonlinear Timoshenko beams in space by boundary feedback

    NASA Astrophysics Data System (ADS)

    Do, K. D.

    2018-05-01

    Boundary feedback controllers are designed to stabilize Timoshenko beams with large translational and rotational motions in space under external disturbances. The exact nonlinear partial differential equations governing motion of the beams are derived and used in the control design. The designed controllers guarantee globally practically asymptotically (and locally practically exponentially) stability of the beam motions at the reference state. The control design, well-posedness and stability analysis are based on various relationships between the earth-fixed and body-fixed coordinates, Sobolev embeddings, and a Lyapunov-type theorem developed to study well-posedness and stability for a class of evolution systems in Hilbert space. Simulation results are included to illustrate the effectiveness of the proposed control design.

  3. Statistical Physics of Rupture in Heterogeneous Media

    NASA Astrophysics Data System (ADS)

    Sornette, Didier

    The damage and fracture of materials are technologically of enormous interest due to their economic and human cost. They cover a wide range of phenomena like cracking of glass, aging of concrete, the failure of fiber networks in the formation of paper and the breaking of a metal bar subject to an external load. Failure of composite systems is of utmost importance in naval, aeronautics and space industry [1]. By the term composite, we refer to materials with heterogeneous microscopic structures and also to assemblages of macroscopic elements forming a super-structure. Chemical and nuclear plants suffer from cracking due to corrosion either of chemical or radioactive origin, aided by thermal and/or mechanical stress.

  4. Simple Electronic Analog of a Josephson Junction.

    ERIC Educational Resources Information Center

    Henry, R. W.; And Others

    1981-01-01

    Demonstrates that an electronic Josephson junction analog constructed from three integrated circuits plus an external reference oscillator can exhibit many of the circuit phenomena of a real Josephson junction. Includes computer and other applications of the analog. (Author/SK)

  5. Health Assessment Document for Diesel Emissions (External Review Draft, 1994) - Volume 2

    EPA Science Inventory

    This document reports on the health effects of diesel combustion emissions, including a quantitative cancer risk assessment, and a reference concentration (non-cancer) for lifetime exposure; atmospheric concentrations, transport, and transformation; inhalation dosimetry; animal t...

  6. Health Assessment Document for Diesel Emissions (External Review Draft, 1994) - Volume 1

    EPA Science Inventory

    This report on the health effects of diesel combustion emissions, includes a quantitative cancer risk assessment, and a reference concentration (non-cancer) for lifetime exposure; atmospheric concentrations, transport, and transformation; inhalation dosimetry; animal toxicology; ...

  7. What are the bias, imprecision, and limits of agreement for finding the flexion-extension plane of the knee with five tibial reference lines?

    PubMed

    Brar, Abheetinder S; Howell, Stephen M; Hull, Maury L

    2016-06-01

    Internal-external (I-E) malrotation of the tibial component is associated with poor function after total knee arthroplasty (TKA). Kinematically aligned (KA) TKA uses a functionally defined flexion-extension (F-E) tibial reference line, which is parallel to the F-E plane of the extended knee, to set I-E rotation of the tibial component. Sixty-two, three-dimensional bone models of normal knees were analyzed. We computed the bias (mean), imprecision (±standard deviation), and limits of agreement (mean±2 standard deviations) of the angle between five anatomically defined tibial reference lines used in mechanically aligned (MA) TKA and the F-E tibial reference line (+external). The following are the bias, imprecision, and limits of agreement of the angle between the F-E tibial reference line and 1) the tibial reference lines connecting the medial border (-2°±6°, -14° to 10°), medial 1/3 (6°±6°, -6° to 18°), and the most anterior point of the tibial tubercle (9°±4°, -1° to 17°) with the center of the posterior cruciate ligament, and 2) the tibial reference lines perpendicular to the posterior condylar axis of the tibia (-3°±4°, -11° to 5°), and a line connecting the centers of the tibial condyles (1°±4°, -7° to 9°). Based on these in vitro findings, it might be prudent to reconsider setting the I-E rotation of the tibial component to tibial reference lines that have bias, imprecision, and limits of agreement that fall outside the -7° to 10° range associated with high function after KA TKA. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Analytical Bias Exceeding Desirable Quality Goal in 4 out of 5 Common Immunoassays: Results of a Native Single Serum Sample External Quality Assessment Program for Cobalamin, Folate, Ferritin, Thyroid-Stimulating Hormone, and Free T4 Analyses.

    PubMed

    Kristensen, Gunn B B; Rustad, Pål; Berg, Jens P; Aakre, Kristin M

    2016-09-01

    We undertook this study to evaluate method differences for 5 components analyzed by immunoassays, to explore whether the use of method-dependent reference intervals may compensate for method differences, and to investigate commutability of external quality assessment (EQA) materials. Twenty fresh native single serum samples, a fresh native serum pool, Nordic Federation of Clinical Chemistry Reference Serum X (serum X) (serum pool), and 2 EQA materials were sent to 38 laboratories for measurement of cobalamin, folate, ferritin, free T4, and thyroid-stimulating hormone (TSH) by 5 different measurement procedures [Roche Cobas (n = 15), Roche Modular (n = 4), Abbott Architect (n = 8), Beckman Coulter Unicel (n = 2), and Siemens ADVIA Centaur (n = 9)]. The target value for each component was calculated based on the mean of method means or measured by a reference measurement procedure (free T4). Quality specifications were based on biological variation. Local reference intervals were reported from all laboratories. Method differences that exceeded acceptable bias were found for all components except folate. Free T4 differences from the uncommonly used reference measurement procedure were large. Reference intervals differed between measurement procedures but also within 1 measurement procedure. The serum X material was commutable for all components and measurement procedures, whereas the EQA materials were noncommutable in 13 of 50 occasions (5 components, 5 methods, 2 EQA materials). The bias between the measurement procedures was unacceptably large in 4/5 tested components. Traceability to reference materials as claimed by the manufacturers did not lead to acceptable harmonization. Adjustment of reference intervals in accordance with method differences and use of commutable EQA samples are not implemented commonly. © 2016 American Association for Clinical Chemistry.

  9. Neurocognitive performance and physical function do not change with physical-cognitive-mindfulness training in female laboratory technicians with chronic musculoskeletal pain

    PubMed Central

    Jay, Kenneth; Brandt, Mikkel; Schraefel, mc; Jakobsen, Markus Due; Sundstrup, Emil; Sjøgaard, Gisela; Vinstrup, Jonas; Andersen, Lars L.

    2016-01-01

    Abstract Background: Cognitive and physical performance can be negatively affected by chronic pain. This study evaluates the effect of combined physical-, cognitive-, and mindfulness training (PCMT) on cognitive and physical performance. Methods: From a large pharmaceutical company in Denmark we randomly allocated 112 female laboratory technicians with chronic upper limb pain to group-based PCMT at the worksite or a reference group for 10 weeks. Neurocognitive performance was measured by the computerized central nervous system vital signs neurocognitive assessment battery. Physical function was assessed in terms of shoulder external rotation strength and rate of force development in a custom-made dynamometer setup. Results: No between-group differences (least square means [95% confidence interval]) from baseline to follow-up could be detected in any of the neurocognitive domains as measured by the central nervous system vital signs neurocognitive assessment battery, for example, Psychomotoer Speed 1.9 (−1.0 to 4.7), Reaction Time −4.0 (−19.5 to 11.6), Complex Attention −0.3 (−1.9 to 1.4), and Executive Function −0.2 (−3.5 to 3.0). Similarly, we found no change in maximal voluntary isometric strength −0.63 (−4.8 to 3.6), or rate of force development 14.8 (−12.6 to 42.2) of the shoulder external rotators. Finally, test–retest reliability of maximal voluntary contraction and rate of force development shoulder external rotation showed high reliability at 0 to 30 ms, 0 to 50 ms, 0 to 100 ms, and 0 to 200 ms with ICCs at 0.95, 0.92, 0.93, 0.92, and 0.91, respectively. Conclusion: Ten weeks of PCMT did not improve neurocognitive or physical performance. PMID:27977585

  10. A design of a valid signal selecting and position decoding ASIC for PET using silicon photomultipliers

    NASA Astrophysics Data System (ADS)

    Cho, M.; Lim, K.-t.; Kim, H.; Yeom, J.-y.; Kim, J.; Lee, C.; Choi, H.; Cho, G.

    2017-01-01

    In most cases, a PET system has numerous electrical components and channel circuits and thus it would rather be a bulky product. Also, most existing systems receive analog signals from detectors which make them vulnerable to signal distortions. For these reasons, channel reduction techniques are important. In this work, an ASIC for PET module is being proposed. An ASIC chip for 16 PET detector channels, VSSPDC, has been designed and simulated. The main function of the chip is 16-to-1 channel reduction, i.e., finding the position of only the valid signals, signal timing, and magnitudes in all 16 channels at every recorded event. The ASIC comprises four of 4-channel modules and a 2nd 4-to-1 router. A single channel module comprises a transimpedance amplifier for the silicon photomultipliers, dual comparators with high and low level references, and a logic circuitry. While the high level reference was used to test the validity of the signal, the low level reference was used for the timing. The 1-channel module of the ASIC produced an energy pulse by time-over-threshold method and it also produced a time pulse with a fixed delayed time. Since the ASIC chip outputs only a few digital pulses and does not require an external clock, it has an advantage over noise properties. The cadence simulation showed the good performance of the chip as designed.

  11. Measuring dose from radiotherapy treatments in the vicinity of a cardiac pacemaker.

    PubMed

    Peet, Samuel C; Wilks, Rachael; Kairn, Tanya; Crowe, Scott B

    2016-12-01

    This study investigated the dose absorbed by tissues surrounding artificial cardiac pacemakers during external beam radiotherapy procedures. The usefulness of out-of-field reference data, treatment planning systems, and skin dose measurements to estimate the dose in the vicinity of a pacemaker was also examined. Measurements were performed by installing a pacemaker onto an anthropomorphic phantom, and using radiochromic film and optically stimulated luminescence dosimeters to measure the dose in the vicinity of the device during the delivery of square fields and clinical treatment plans. It was found that the dose delivered in the vicinity of the cardiac device was unevenly distributed both laterally and anteroposteriorly. As the device was moved distally from the square field, the dose dropped exponentially, in line with out-of-field reference data in the literature. Treatment planning systems were found to substantially underestimate the dose for volumetric modulated arc therapy, helical tomotherapy, and 3D conformal treatments. The skin dose was observed to be either greater or lesser than the dose received at the depth of the device, depending on the treatment site, and so care should be if skin dose measurements are to be used to estimate the dose to a pacemaker. Square field reference data may be used as an upper estimate of absorbed dose per monitor unit in the vicinity of a cardiac device for complex treatments involving multiple gantry angles. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  12. Laser scanning-based recognition of rotational movements on a deep seated gravitational instability: The Cinque Torri case (North-Eastern Italian Alps)

    NASA Astrophysics Data System (ADS)

    Viero, Alessia; Teza, Giordano; Massironi, Matteo; Jaboyedoff, Michel; Galgaro, Antonio

    2010-10-01

    The Cinque Torri group (Cortina d'Ampezzo, Italy) is an articulated system of unstable carbonatic rock monoliths located in a very important tourism area and therefore characterized by a significant risk. The instability phenomena involved represent an example of lateral spreading developed over a larger deep seated gravitational slope deformation (DSGSD) area. After the recent fall of a monolith of more than 10 000 m 3, a scientific study was initiated to monitor the more unstable sectors and to characterize the past movements as a fundamental tool for predicting future movements and hazard assessment. To achieve greater insight on the ongoing lateral spreading process, a method for a quantitative analysis of rotational movements associated with the lateral spreading has been developed, applied and validated. The method is based on: i) detailed geometrical characterization of the area by means of laser scanner techniques; ii) recognition of the discontinuity sets and definition of a reference frame for each set, iii) correlation between the obtained reference frames related to a specific sector and a stable external reference frame, and iv) determination of the 3D rotations in terms of Euler angles to describe the present settlement of the Cinque Torri system with respect to the surrounding stable areas. In this way, significant information on the processes involved in the fragmentation and spreading of a former dolomitic plateau into different rock cliffs has been gained. The method is suitable to be applied to similar case studies.

  13. Impact of pre-imputation SNP-filtering on genotype imputation results

    PubMed Central

    2014-01-01

    Background Imputation of partially missing or unobserved genotypes is an indispensable tool for SNP data analyses. However, research and understanding of the impact of initial SNP-data quality control on imputation results is still limited. In this paper, we aim to evaluate the effect of different strategies of pre-imputation quality filtering on the performance of the widely used imputation algorithms MaCH and IMPUTE. Results We considered three scenarios: imputation of partially missing genotypes with usage of an external reference panel, without usage of an external reference panel, as well as imputation of completely un-typed SNPs using an external reference panel. We first created various datasets applying different SNP quality filters and masking certain percentages of randomly selected high-quality SNPs. We imputed these SNPs and compared the results between the different filtering scenarios by using established and newly proposed measures of imputation quality. While the established measures assess certainty of imputation results, our newly proposed measures focus on the agreement with true genotypes. These measures showed that pre-imputation SNP-filtering might be detrimental regarding imputation quality. Moreover, the strongest drivers of imputation quality were in general the burden of missingness and the number of SNPs used for imputation. We also found that using a reference panel always improves imputation quality of partially missing genotypes. MaCH performed slightly better than IMPUTE2 in most of our scenarios. Again, these results were more pronounced when using our newly defined measures of imputation quality. Conclusion Even a moderate filtering has a detrimental effect on the imputation quality. Therefore little or no SNP filtering prior to imputation appears to be the best strategy for imputing small to moderately sized datasets. Our results also showed that for these datasets, MaCH performs slightly better than IMPUTE2 in most scenarios at the cost of increased computing time. PMID:25112433

  14. TU-D-201-03: Results of a Survey On the Implementation of the TG-51 Protocol and Associated Addendum On Reference Dosimetry of External Beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, G; Muir, B; Culberson, W

    Purpose: The working group on the review and extension of the TG-51 protocol (WGTG51) collected data from American Association of Physicists in Medicine (AAPM) members with respect to their current TG-51 and associated addendum usage in the interest of considering future protocol addenda and guidance on reference dosimetry best practices. This study reports an overview of this survey on dosimetry of external beams. Methods: Fourteen survey questions were developed by WGTG51 and released in November 2015. The questions collected information on reference dosimetry, beam quality specification, and ancillary calibration equipment. Results: Of the 190 submissions completed worldwide (U.S. 70%), 83%more » were AAPM members. Of the respondents, 33.5% implemented the TG-51 addendum, with the maximum calibration difference for any photon beam, with respect to the original TG-51 protocol, being <1% for 97.4% of responses. One major finding is that 81.8% of respondents used the same cylindrical ionization chamber for photon and electron dosimetry, implying that many clinics are foregoing the use of parallel-plate chambers. Other evidence suggests equivalent dosimetric results can be obtained with both cylindrical and parallel-plate chambers in electron beams. This, combined with users comfort with cylindrical chambers for electrons will likely impact recommendations put forward in an upcoming electron beam addendum to the TG-51 protocol. Data collected on ancillary equipment showed 58.2% (45.0%) of the thermometers (barometers) in use for beam calibration had NIST traceable calibration certificates, but 48.4% (42.7%) were never recalibrated. Conclusion: This survey provides a snapshot of TG-51 external beam reference dosimetry practice in radiotherapy centers. Findings demonstrate the rapid take-up of the TG-51 photon beam addendum and raise issues for the WGTG51 to focus on going forward, including guidelines on ancillary equipment and the choice of chamber for electron beam dosimetry.« less

  15. Multigrid Computations of 3-D Incompressible Internal and External Viscous Rotating Flows

    NASA Technical Reports Server (NTRS)

    Sheng, Chunhua; Taylor, Lafayette K.; Chen, Jen-Ping; Jiang, Min-Yee; Whitfield, David L.

    1996-01-01

    This report presents multigrid methods for solving the 3-D incompressible viscous rotating flows in a NASA low-speed centrifugal compressor and a marine propeller 4119. Numerical formulations are given in both the rotating reference frame and the absolute frame. Comparisons are made for the accuracy, efficiency, and robustness between the steady-state scheme and the time-accurate scheme for simulating viscous rotating flows for complex internal and external flow applications. Prospects for further increase in efficiency and accuracy of unsteady time-accurate computations are discussed.

  16. Primary Synovial Sarcoma of External Auditory Canal: A Case Report

    PubMed Central

    Jayakumar, Krishnannair l L

    2017-01-01

    Synovial sarcoma is a rare malignant tumor of mesenchymal origin. Primary synovial sarcoma of the ear is extremely rare and to date only two cases have been published in English medical literature. Though the tumor is reported to have an aggressive nature, early diagnosis and treatment may improve the outcome. Here, we report a rare case of synovial sarcoma of the external auditory canal in an 18-year-old male who was managed by chemotherapy and referred for palliation due to tumor progression. PMID:28948118

  17. Requirements for data integration platforms in biomedical research networks: a reference model

    PubMed Central

    Knaup, Petra

    2015-01-01

    Biomedical research networks need to integrate research data among their members and with external partners. To support such data sharing activities, an adequate information technology infrastructure is necessary. To facilitate the establishment of such an infrastructure, we developed a reference model for the requirements. The reference model consists of five reference goals and 15 reference requirements. Using the Unified Modeling Language, the goals and requirements are set into relation to each other. In addition, all goals and requirements are described textually in tables. This reference model can be used by research networks as a basis for a resource efficient acquisition of their project specific requirements. Furthermore, a concrete instance of the reference model is described for a research network on liver cancer. The reference model is transferred into a requirements model of the specific network. Based on this concrete requirements model, a service-oriented information technology architecture is derived and also described in this paper. PMID:25699205

  18. Telemetric implantable pressure sensor for short- and long-term monitoring of intracranial pressure.

    PubMed

    Frischholz, M; Sarmento, L; Wenzel, M; Aquilina, K; Edwards, R; Coakham, H B

    2007-01-01

    Patients with hydrocephalus, idiopathic intracranial hypertension and head injury frequently require monitoring of intracranial pressure (ICP) and may need repeated episodes of monitoring months or years apart. The gold standard for measurement of ICP remains the external ventricular catheter. This is a fluid-filled catheter transducer system that allows regular recalibration and correction of zero drift by its position relative to a fixed anatomical reference. It also allows drainage of cerebrospinal fluid (CSF), providing a means of lowering the ICP. Several catheter tip transducer systems are currently in clinical use, including using strain gauges or fiber-optical pressure sensing techniques. In these devices, zero drift and calibration cannot be checked in vivo. All the ICP monitoring devices in current clinical use require a physical connection between the brain and the external environment. This is a source of infection and limits the duration of monitoring. A number of telemetric monitoring devices, in which data is in some way transmitted transcutaneously, have been developed over the last twenty years, but significant technical problems have precluded their use in routine clinical practice. All current ICP monitors are temporary percutaneous implanted devices. Placement of these devices carries significant morbidity, particularly infection. Patients undergoing repeated monitoring require multiple surgical procedures. Apart from decreasing the risk of infection in patients with severe head injury, the clinical value of an accurate telemetric ICP monitoring system which maintains its reliability over a long period of implantation is high.

  19. Differences in external price referencing in Europe: a descriptive overview.

    PubMed

    Leopold, Christine; Vogler, Sabine; Mantel-Teeuwisse, A K; de Joncheere, Kees; Leufkens, H G M; Laing, Richard

    2012-01-01

    This study aimed to provide an up-to-date description as well as comparative analysis of the national characteristics of pharmaceutical external price referencing (EPR) in Europe. Review of the country-specific PPRI (Pharmaceutical Pricing and Reimbursement Information) Pharma Profiles written by representatives of the PPRI Network. The Profiles were analysed according to predefined criteria. Of 28 analysed European countries 24 applied EPR in 2010. The majority of countries have statutory rules to implement EPR. Most countries had less than 10 countries in their reference baskets. Higher income countries tend to include higher income countries in their basket, whereas lower income countries refer to lower income countries. Taking the average price of all countries in the basket as the basis to calculate the national price was the most common strategy (n=8). The methodology of EPR has changed in most European countries over the past 10 years (n=19). EPR is a widely used pricing policy in Europe and is still actively used as well as adjusted by national authorities. However, we still see room for improvement by implementing more detailed legislations in terms of the revision of prices and by identifying alternative countries in case a product is not on the market. We also see the need for formal information sharing (e.g. congresses dedicated to pricing strategies and systems) with other public pricing authorities to learn about the different EPR methodologies as well as the national experiences. These congresses might also give room to better understand national pricing methods including discussions on possible limitations of these pricing methods. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  20. Postural orientation and equilibrium: what do we need to know about neural control of balance to prevent falls?

    PubMed

    Horak, Fay B

    2006-09-01

    Postural control is no longer considered simply a summation of static reflexes but, rather, a complex skill based on the interaction of dynamic sensorimotor processes. The two main functional goals of postural behaviour are postural orientation and postural equilibrium. Postural orientation involves the active alignment of the trunk and head with respect to gravity, support surfaces, the visual surround and internal references. Sensory information from somatosensory, vestibular and visual systems is integrated, and the relative weights placed on each of these inputs are dependent on the goals of the movement task and the environmental context. Postural equilibrium involves the coordination of movement strategies to stabilise the centre of body mass during both self-initiated and externally triggered disturbances of stability. The specific response strategy selected depends not only on the characteristics of the external postural displacement but also on the individual's expectations, goals and prior experience. Anticipatory postural adjustments, prior to voluntary limb movement, serve to maintain postural stability by compensating for destabilising forces associated with moving a limb. The amount of cognitive processing required for postural control depends both on the complexity of the postural task and on the capability of the subject's postural control system. The control of posture involves many different underlying physiological systems that can be affected by pathology or sub-clinical constraints. Damage to any of the underlying systems will result in different, context-specific instabilities. The effective rehabilitation of balance to improve mobility and to prevent falls requires a better understanding of the multiple mechanisms underlying postural control.

  1. Externalizing behavior from early childhood to adolescence: Prediction from inhibition, language, parenting, and attachment.

    PubMed

    Roskam, Isabelle

    2018-03-22

    The aim of the current research was to disentangle four theoretically sound models of externalizing behavior etiology (i.e., attachment, language, inhibition, and parenting) by testing their relation with behavioral trajectories from early childhood to adolescence. The aim was achieved through a 10-year prospective longitudinal study conducted over five waves with 111 referred children aged 3 to 5 years at the onset of the study. Clinical referral was primarily based on externalizing behavior. A multimethod (questionnaires, testing, and observations) approach was used to estimate the four predictors in early childhood. In line with previous studies, the results show a significant decrease of externalizing behavior from early childhood to adolescence. The decline was negatively related to mothers' coercive parenting and positively related to attachment security in early childhood, but not related to inhibition and language. The study has implications for research into externalizing behavior etiology recommending to gather hypotheses from various theoretically sound models to put them into competition with one another. The study also has implications for clinical practice by providing clear indications for prevention and early intervention.

  2. Home Page: NYS Government Information Locator Service: New York State

    Science.gov Websites

    Constitution external link - from the New York State Department of State NYS Judicial System (NYS Unified Courts System) Unified Court System external link - the main resource for information about New York's decisions of the New York courts in the Official Reports. The searchable Legal Research Portal external link

  3. External tank project new technology plan. [development of space shuttle external tank system

    NASA Technical Reports Server (NTRS)

    1973-01-01

    A production plan for the space shuttle external tank configuration is presented. The subjects discussed are: (1) the thermal protection system, (2) thermal coating application techniques, (3) manufacturing and tooling, (4) propulsion system configurations and components, (5) low temperature rotating and sliding joint seals, (6) lightning protection, and (7) nondestructive testing technology.

  4. Z-M in Lightning Forecasting

    DTIC Science & Technology

    2009-03-01

    hydrometers create a charge separation. Inductive processes rely on a preexisting external electric field to induce charges on polarized particles, which...frozen hydrometers . A. FLORIDA CLIMATE Florida is often referred to as the lightning capital of the United States (Hodanish et al. 1997) or

  5. A Simple Tiltmeter

    NASA Technical Reports Server (NTRS)

    Dix, M. G.; Harrison, D. R.; Edwards, T. M.

    1982-01-01

    Bubble vial with external aluminum-foil electrodes is sensing element for simple indicating tiltmeter. To measure bubble displacement, bridge circuit detects difference in capacitance between two sensing electrodes and reference electrode. Tiltmeter was developed for experiment on forecasting seismic events by changes in Earth's magnetic field.

  6. Studying Sensory Perception.

    ERIC Educational Resources Information Center

    Ackerly, Spafford C.

    2001-01-01

    Explains the vestibular organ's role in balancing the body and stabilizing the visual world using the example of a hunter. Describes the relationship between sensory perception and learning. Recommends using optical illusions to illustrate the distinctions between external realities and internal perceptions. (Contains 13 references.) (YDS)

  7. Genetics Home Reference: progressive external ophthalmoplegia

    MedlinePlus

    ... within cells that use oxygen to convert the energy from food into a form cells can use. This process is called oxidative phosphorylation. Although most DNA is packaged in chromosomes within the nucleus (nuclear DNA), mitochondria also have a small amount of ...

  8. [Effect of staining method and sintering temperature on the color of porcelain-fused-to-metal restorations].

    PubMed

    Wang, Yan; Yan, Wei-hao; Zhang, Xin-chun; Huang, Yue; Shen, Lin-han

    2004-12-01

    To investigate the effect of staining method and sintering temperature on the color of porcelain-fused-metal restorations. 40 cylindrical stained porcelain-metal specimens of 15 mm in diameter and 6 mm in height were fabricated with customized mould, consisting of 2 mm Ni-Cr metal, 1 mm opaque porcelain, 2 mm dentine porcelain and 1 mm enamel porcelain. The specimens were prepared by 5 techniques, 8 for each group. Group A: internal staining, Group B: external staining, 900 degrees centigrade sintering temperature was used in both A and B group; Group C to E: external staining, with the sintering temperature of 880 degrees centigrade, 900 degrees centigrade and 920 degrees centigrade respectively. Sofu A2 porcelain and Sofu 44 stain system were used for the study. Using standard white plate as a reference, colors (L*,a*,b* coordinates) of the specimens were measured with a computerized colorimeter. Student's t test and one way ANOVA were used to analyze the data. DeltaE, b* and Delta C(ab)* of Group B (external staining) and group A (internal staining) were 43.72 +/- 2.99/26.51 +/- 1.64/31.31 +/- 2.48 and 39.71 +/- 1.78/23.69 +/- 0.36/26.55 +/- 2.16, respectively. The values of the former group were significantly higher than that of the latter (P < 0.05); For Group C to E, there were no significant differences in all the color parameters. Staining method has a significant effect on the color parameters of porcelain-fused-to-metal restorations; For external staining, within the clinically-used range, changing the sintering temperature does not have an obvious effect on the color.

  9. An SINS/GNSS Ground Vehicle Gravimetry Test Based on SGA-WZ02.

    PubMed

    Yu, Ruihang; Cai, Shaokun; Wu, Meiping; Cao, Juliang; Zhang, Kaidong

    2015-09-16

    In March 2015, a ground vehicle gravimetry test was implemented in eastern Changsha to assess the repeatability and accuracy of ground vehicle SINS/GNSS gravimeter-SGA-WZ02. The gravity system developed by NUDT consisted of a Strapdown Inertial Navigation System (SINS), a Global Navigation Satellite System (GNSS) remote station on test vehicle, a GNSS static master station on the ground, and a data logging subsystem. A south-north profile of 35 km along the highway in eastern Changsha was chosen and four repeated available measure lines were obtained. The average speed of a vehicle is 40 km/h. To assess the external ground gravity disturbances, precise ground gravity data was built by CG-5 precise gravimeter as the reference. Under relative smooth conditions, internal accuracy among repeated lines shows an average agreement at the level of 1.86 mGal for half wavelengths about 1.1 km, and 1.22 mGal for 1.7 km. The root-mean-square (RMS) of difference between calculated gravity data and reference data is about 2.27 mGal/1.1 km, and 1.74 mGal/1.7 km. Not all of the noises caused by vehicle itself and experiments environments were eliminated in the primary results. By means of selecting reasonable filters and improving the GNSS observation conditions, further developments in ground vehicle gravimetry are promising.

  10. Investigation of noise sources and propagation in external gear pumps

    NASA Astrophysics Data System (ADS)

    Opperwall, Timothy J.

    Oil hydraulics is widely accepted as the best technology for transmitting power in many engineering applications due to its advantages in power density, control, layout flexibility, and efficiency. Due to these advantages, hydraulic systems are present in many different applications including construction, agriculture, aerospace, automotive, forestry, medical, and manufacturing, just to identify a few. Many of these applications involve the systems in close proximity to human operators and passengers where noise is one of the main constraints to the acceptance and spread of this technology. As a key component in power transfer, displacement machines can be major sources of noise in hydraulic systems. Thus, investigation into the sources of noise and discovering strategies to reduce noise is a key part of applying fluid power systems to a wider range of applications, as well as improving the performance of current hydraulic systems. The present research aims to leverage previous efforts and develop new models and experimental techniques in the topic of noise generation caused by hydrostatic units. This requires challenging and surpassing current accepted methods in the understanding of noise in fluid power systems. This research seeks to expand on the previous experimental and modeling efforts by directly considering the effect that system and component design changes apply on the total sound power and the sound frequency components emitted from displacement machines and the attached lines. The case of external gear pumps is taken as reference for a new model to understand the generation and transmission of noise from the sources out to the environment. The lumped parameter model HYGESim (HYdraulic GEar machine Simulator) was expanded to investigate the dynamic forces on the solid bodies caused by the pump operation and to predict interactions with the attached system. Vibration and sound radiation were then predicted using a combined finite element and boundary element vibro-acoustic model as well as the influence of additional models for system components to better understand the essential problems of noise generation in hydraulic systems. This model is a step forward for the field due to the coupling of an advanced internal model of pump operation coupled to a detailed vibro-acoustic model. Several experimental studies were also completed in order to advance the current science. The first study validated the pump model in terms of outlet pressure ripple prediction through comparison to experimentally measured results for the reference pump as well as prototype pumps designed for low outlet pressure ripple. The second study focused on the air-borne noise through sound pressure and intensity measurements on reference and prototype pumps at steady-state operating conditions. A third study over a wide range of operating speeds and pressures was completed to explore the impact of operating condition and system design to greater detail through measuring noise and vibration in the working fluid, the system structures, and the air. Applying the knowledge gained through experimental and simulation studies has brought new advances in the understanding of the physics of noise generation and propagation in hydraulic components and systems. The focus of the combined simulation and modeling approach is to clearly understand the different contributions from noise sources and surpasses the previous methods that focus on the outlet pressure ripple alone as a source of noise. The application of the new modeling and experimental approach allows for new advances which directly contribute to advancing the science of noise in hydraulic applications and the design of new quieter hydrostatic units and hydraulic systems.

  11. DREISS: Using State-Space Models to Infer the Dynamics of Gene Expression Driven by External and Internal Regulatory Networks

    PubMed Central

    Gerstein, Mark

    2016-01-01

    Gene expression is controlled by the combinatorial effects of regulatory factors from different biological subsystems such as general transcription factors (TFs), cellular growth factors and microRNAs. A subsystem’s gene expression may be controlled by its internal regulatory factors, exclusively, or by external subsystems, or by both. It is thus useful to distinguish the degree to which a subsystem is regulated internally or externally–e.g., how non-conserved, species-specific TFs affect the expression of conserved, cross-species genes during evolution. We developed a computational method (DREISS, dreiss.gerteinlab.org) for analyzing the Dynamics of gene expression driven by Regulatory networks, both External and Internal based on State Space models. Given a subsystem, the “state” and “control” in the model refer to its own (internal) and another subsystem’s (external) gene expression levels. The state at a given time is determined by the state and control at a previous time. Because typical time-series data do not have enough samples to fully estimate the model’s parameters, DREISS uses dimensionality reduction, and identifies canonical temporal expression trajectories (e.g., degradation, growth and oscillation) representing the regulatory effects emanating from various subsystems. To demonstrate capabilities of DREISS, we study the regulatory effects of evolutionarily conserved vs. divergent TFs across distant species. In particular, we applied DREISS to the time-series gene expression datasets of C. elegans and D. melanogaster during their embryonic development. We analyzed the expression dynamics of the conserved, orthologous genes (orthologs), seeing the degree to which these can be accounted for by orthologous (internal) versus species-specific (external) TFs. We found that between two species, the orthologs have matched, internally driven expression patterns but very different externally driven ones. This is particularly true for genes with evolutionarily ancient functions (e.g. the ribosomal proteins), in contrast to those with more recently evolved functions (e.g., cell-cell communication). This suggests that despite striking morphological differences, some fundamental embryonic-developmental processes are still controlled by ancient regulatory systems. PMID:27760135

  12. Primary investigation the impacts of the external memory (DDR3) failures on the performance of Xilinx Zynq-7010 SoC based system (MicroZed) using laser irradiation

    NASA Astrophysics Data System (ADS)

    Liu, Shuhuan; Du, Xuecheng; Du, Xiaozhi; Zhang, Yao; Mubashiru, Lawal Olarewaju; Luo, Dongyang; yuan, Yuan; Deng, Tianxiang; Li, Zhuoqi; Zang, Hang; Li, Yonghong; He, Chaohui; Ma, Yingqi; Shangguan, Shipeng

    2017-09-01

    The impacts of the external dynamic memory (DDR3) failures on the performance of 28 nm Xilinx Zynq-7010 SoC based system (MicroZed) were investigated with two sets of 1064 nm laser platforms. The failure sensitive area distributionsons on the back surface of the test DDR3 were primarily localized with a CW laser irradiation platform. During the CW laser scanning on the back surface of the DDR3 of the test board system, various failure modes except SEU and SEL (MBU, SEFI, data storage address error, rebooting, etc) were found in the testing embedded modules (ALU, PL, Register, Cache and DMA, etc) of SoC. Moreover, the experimental results demonstrated that there were 16 failure sensitive blocks symmetrically distributed on the back surface of the DDR3 with every sensitive block area measured was about 1 mm × 0.5 mm. The influence factors on the failure modes of the embedded modules were primarily analyzed and the SEE characteristics of DDR3 induced by the picoseconds pulsed laser were tested. The failure modes of DDR3 found were SEU, SEFI, SEL, test board rebooting by itself, unknown data, etc. Furthermore, the time interval distributions of failure occurrence in DDR3 changes with the pulsed laser irradiation energy and the CPU operating frequency were measured and compared. Meanwhile, the failure characteristics of DDR3 induced by pulsed laser irradiation were primarily explored. The measured results and the testing techniques designed in this paper provide some reference information for evaluating the reliability of the test system or other similar electronic system in harsh environment.

  13. Spin polarization effects and their time evolutions

    NASA Astrophysics Data System (ADS)

    Vernes, A.; Weinberger, P.

    2015-04-01

    The time evolution of the density corresponding to the polarization operator, originally constructed to commute with the Dirac Hamiltonian in the absence of an external electromagnetic field, is investigated in terms of the time-dependent Dirac equation taking the presence of an external electromagnetic field into account. It is found that this time evolution leads to 'tensorial' and 'vectorial' particle current densities and to the interaction of the spin density with the external electromagnetic field. As the time evolution of the spin density does not refer to a constant of motion (continuity condition) it only serves as auxiliary density. By taking the non-relativistic limit, it is shown that the polarization, spin and magnetization densities are independent of electric field effects and, in addition, no preferred directions can be defined.

  14. Air Quality Criteria for Lead (First External Review Draft)

    EPA Science Inventory

    Background:

    The Clean Air Act mandates periodic review of the National Ambient Air Quality Standards (NAAQS) for six common air pollutants, also referred to as criteria pollutants, including lead. Under the review process, EPA's Office of Research and Development d...

  15. Polytechnics in a "Postmarket" Environment.

    ERIC Educational Resources Information Center

    McNae, Denny

    2002-01-01

    Interviews with chief executive officers of three New Zealand polytechnics elicited themes regarding polytechnics' role in a "postmarket" environment: (1) collaboration is possible amidst fierce competition; (2) change is slow, externally driven, and complex; and (3) the polytechnic sector is in disarray. (Contains 27 references.) (SK)

  16. 77 FR 74103 - Alternatives to the Use of Credit Ratings

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-13

    ... NPRM identified references made to nationally recognized statistical rating organization (NRSRO) \\3... or external credit risk assessments (including credit ratings), and default statistics. The preamble...); Default statistics (i.e., whether providers of credit information relating to securities express a view...

  17. Resonator modes and mode dynamics for an external cavity-coupled laser array

    NASA Astrophysics Data System (ADS)

    Nair, Niketh; Bochove, Erik J.; Aceves, Alejandro B.; Zunoubi, Mohammad R.; Braiman, Yehuda

    2015-03-01

    Employing a Fox-Li approach, we derived the cold-cavity mode structure and a coupled mode theory for a phased array of N single-transverse-mode active waveguides with feedback from an external cavity. We applied the analysis to a system with arbitrary laser lengths, external cavity design and coupling strengths to the external cavity. The entire system was treated as a single resonator. The effect of the external cavity was modeled by a set of boundary conditions expressed by an N-by-N frequency-dependent matrix relation between incident and reflected fields at the interface with the external cavity. The coupled mode theory can be adapted to various types of gain media and internal and external cavity designs.

  18. Quality and Safety in Health Care, Part XIV: The External Environment and Research for Diagnostic Processes.

    PubMed

    Harolds, Jay A

    2016-09-01

    The work system in which diagnosis takes place is affected by the external environment, which includes requirements such as certification, accreditation, and regulations. How errors are reported, malpractice, and the system for payment are some other aspects of the external environment. Improving the external environment is expected to decrease errors in diagnosis. More research on improving the diagnostic process is needed.

  19. IVS contribution to ITRF2014

    NASA Astrophysics Data System (ADS)

    Bachmann, Sabine; Thaller, Daniela; Roggenbuck, Ole; Lösler, Michael; Messerschmitt, Linda

    2016-07-01

    Every few years the International Terrestrial Reference System (ITRS) Center of the International Earth Rotation and Reference Systems Service (IERS) decides to generate a new version of the International Terrestrial Reference Frame (ITRF). For the upcoming ITRF2014 the official contribution of the International VLBI Service for Geodesy and Astrometry (IVS) comprises 5796 combined sessions in SINEX file format from 1979.6 to 2015.0 containing 158 stations, overall. Nine AC contributions were included in the combination process, using five different software packages. Station coordinate time series of the combined solution show an overall repeatability of 3.3 mm for the north, 4.3 mm for the east and 7.5 mm for the height component over all stations. The minimum repeatabilities are 1.5 mm for north, 2.1 mm for east and 2.9 mm for height. One of the important differences between the IVS contribution to the ITRF2014 and the routine IVS combination is the omission of the correction for non-tidal atmospheric pressure loading (NTAL). Comparisons between the amplitudes of the annual signals derived by the VLBI observations and the annual signals from an NTAL model show that for some stations, NTAL has a high impact on station height variation. For other stations, the effect of NTAL is low. Occasionally other loading effects have a higher influence (e.g. continental water storage loading). External comparisons of the scale parameter between the VTRF2014 (a TRF based on combined VLBI solutions), DTRF2008 (DGFI-TUM realization of ITRS) and ITRF2008 revealed a significant difference in the scale. A scale difference of 0.11 ppb (i.e. 0.7 mm on the Earth's surface) has been detected between the VTRF2014 and the DTRF2008, and a scale difference of 0.44 ppb (i.e. 2.8 mm on the Earth's surface) between the VTRF2014 and ITRF2008. Internal comparisons between the EOP of the combined solution and the individual solutions from the AC contributions show a WRMS in X- and Y-Pole between 40 and 100 \\upmu as and for dUT1 between 5 and 15 \\upmu s. External comparisons with respect to the IERS-08-C04 series show a WRMS of 132 and 143 \\upmu as for X- and Y-Pole, respectively, and 13 \\upmu s for dUT.

  20. IPS - a vision aided navigation system

    NASA Astrophysics Data System (ADS)

    Börner, Anko; Baumbach, Dirk; Buder, Maximilian; Choinowski, Andre; Ernst, Ines; Funk, Eugen; Grießbach, Denis; Schischmanow, Adrian; Wohlfeil, Jürgen; Zuev, Sergey

    2017-04-01

    Ego localization is an important prerequisite for several scientific, commercial, and statutory tasks. Only by knowing one's own position, can guidance be provided, inspections be executed, and autonomous vehicles be operated. Localization becomes challenging if satellite-based navigation systems are not available, or data quality is not sufficient. To overcome this problem, a team of the German Aerospace Center (DLR) developed a multi-sensor system based on the human head and its navigation sensors - the eyes and the vestibular system. This system is called integrated positioning system (IPS) and contains a stereo camera and an inertial measurement unit for determining an ego pose in six degrees of freedom in a local coordinate system. IPS is able to operate in real time and can be applied for indoor and outdoor scenarios without any external reference or prior knowledge. In this paper, the system and its key hardware and software components are introduced. The main issues during the development of such complex multi-sensor measurement systems are identified and discussed, and the performance of this technology is demonstrated. The developer team started from scratch and transfers this technology into a commercial product right now. The paper finishes with an outlook.

  1. Studies of felonious crimes by the University Department of Forensic Medicine in Kumamoto Prefecture, Japan.

    PubMed

    Tsunenari, S; Kibayashi, K; Honjyo, K; Hamada, C

    1993-01-01

    This paper gives an understanding of Japan in the respect of forensic medicine. The fight against felonious crimes in Kumamoto is introduced by reference to the police system, crime statistics, an association of police surgeons and medico-legal autopsy in Kumamoto Prefecture. The police have 23 local police stations with 2,670 police officers and the unique Hashutsu-sho and Chyuzai-sho systems. The crime rate is not very high, but crimes committed by Yakuza groups and traffic accidents are major problems in Kumamoto. Medico-legal autopsy is performed in the university department on only criminal and suspected cases after examination of the body externally by a police surgeon. Two illustrative cases are also introduced in this report, which shows good cooperation among the police force, the university department of forensic medicine, and police surgeons in Kumamoto, Japan.

  2. Dynamic information routing in complex networks

    PubMed Central

    Kirst, Christoph; Timme, Marc; Battaglia, Demian

    2016-01-01

    Flexible information routing fundamentally underlies the function of many biological and artificial networks. Yet, how such systems may specifically communicate and dynamically route information is not well understood. Here we identify a generic mechanism to route information on top of collective dynamical reference states in complex networks. Switching between collective dynamics induces flexible reorganization of information sharing and routing patterns, as quantified by delayed mutual information and transfer entropy measures between activities of a network's units. We demonstrate the power of this mechanism specifically for oscillatory dynamics and analyse how individual unit properties, the network topology and external inputs co-act to systematically organize information routing. For multi-scale, modular architectures, we resolve routing patterns at all levels. Interestingly, local interventions within one sub-network may remotely determine nonlocal network-wide communication. These results help understanding and designing information routing patterns across systems where collective dynamics co-occurs with a communication function. PMID:27067257

  3. Conduction Electrohydrodynamics with Mobile Electrodes: A Novel Actuation System for Untethered Robots

    PubMed Central

    Shigemune, Hiroki; Cianchetti, Matteo; Laschi, Cecilia

    2017-01-01

    Electrohydrodynamics (EHD) refers to the direct conversion of electrical energy into mechanical energy of a fluid. Through the use of mobile electrodes, this principle is exploited in a novel fashion for designing and testing a millimeter‐scale untethered robot, which is powered harvesting the energy from an external electric field. The robot is designed as an inverted sail‐boat, with the thrust generated on the sail submerged in the liquid. The diffusion constant of the robot is experimentally computed, proving that its movement is not driven by thermal fluctuations, and then its kinematic and dynamic responses are characterized for different applied voltages. The results show the feasibility of using EHD with mobile electrodes for powering untethered robots and provide new evidences for the further development of this actuation system for both mobile robots and compliant actuators in soft robotics. PMID:28932659

  4. A long-range and long-life telemetry data-acquisition system for heart rate and multiple body temperatures from free-ranging animals

    NASA Technical Reports Server (NTRS)

    Lund, G. F.; Westbrook, R. M.; Fryer, T. B.; Miranda, R. F.

    1979-01-01

    The system includes an implantable transmitter, external receiver-retransmitter collar, and a microprocessor-controlled demodulator. The size of the implant is suitable for animals with body weights of a few kilograms or more; further size reduction of the implant is possible. The ECG is sensed by electrodes designed for internal telemetry and to reduce movement artifacts. The R-wave characteristics are then specifically selected to trigger a short radio frequency pulse. Temperatures are sensed at desired locations by thermistors and then, based on a heartbeat counter, transmitted intermittently via pulse interval modulation. This modulation scheme includes first and last calibration intervals for a reference by ratios with the temperature intervals to achieve good accuracy even over long periods. Pulse duration and pulse sequencing are used to discriminate between heart rate and temperature pulses as well as RF interference.

  5. Gyroscope-reduced inertial navigation system for flight vehicle motion estimation

    NASA Astrophysics Data System (ADS)

    Wang, Xin; Xiao, Lu

    2017-01-01

    In this paper, a novel configuration of strategically distributed accelerometer sensors with the aid of one gyro to infer a flight vehicle's angular motion is presented. The MEMS accelerometer and gyro sensors are integrated to form a gyroscope-reduced inertial measurement unit (GR-IMU). The motivation for gyro aided accelerometers array is to have direct measurements of angular rates, which is an improvement to the traditional gyroscope-free inertial system that employs only direct measurements of specific force. Some technical issues regarding error calibration in accelerometers and gyro in GR-IMU are put forward. The GR-IMU based inertial navigation system can be used to find a complete attitude solution for flight vehicle motion estimation. Results of numerical simulation are given to illustrate the effectiveness of the proposed configuration. The gyroscope-reduced inertial navigation system based on distributed accelerometer sensors can be developed into a cost effective solution for a fast reaction, MEMS based motion capture system. Future work will include the aid from external navigation references (e.g. GPS) to improve long time mission performance.

  6. [Development of a secure and cost-effective infrastructure for the access of arbitrary web-based image distribution systems].

    PubMed

    Hackländer, T; Kleber, K; Schneider, H; Demabre, N; Cramer, B M

    2004-08-01

    To build an infrastructure that enables radiologists on-call and external users a teleradiological access to the HTML-based image distribution system inside the hospital via internet. In addition, no investment costs should arise on the user side and the image data should be sent renamed using cryptographic techniques. A pure HTML-based system manages the image distribution inside the hospital, with an open source project extending this system through a secure gateway outside the firewall of the hospital. The gateway handles the communication between the external users and the HTML server within the network of the hospital. A second firewall is installed between the gateway and the external users and builds up a virtual private network (VPN). A connection between the gateway and the external user is only acknowledged if the computers involved authenticate each other via certificates and the external users authenticate via a multi-stage password system. All data are transferred encrypted. External users get only access to images that have been renamed to a pseudonym by means of automated processing before. With an ADSL internet access, external users achieve an image load frequency of 0.4 CT images per second. More than 90 % of the delay during image transfer results from security checks within the firewalls. Data passing the gateway induce no measurable delay. Project goals were realized by means of an infrastructure that works vendor independently with any HTML-based image distribution systems. The requirements of data security were realized using state-of-the-art web techniques. Adequate access and transfer speed lead to a widespread acceptance of the system on the part of external users.

  7. An experimental study of phase transitions in a complex plasma

    NASA Astrophysics Data System (ADS)

    Smith, Bernard Albert Thomas, II

    In semiconductor manufacturing, contamination due to particulates significantly decreases the yield and quality of device fabrication, therefore increasing the cost of production. Dust particle clouds can be found in almost all plasma processing environments including both plasma etching devices and in plasma deposition processes. Dust particles suspended within such plasmas will acquire an electric charge from collisions with free electrons in the plasma. If the ratio of inter-particle potential energy to the average kinetic energy is sufficient, the particles will form either a "liquid" structure with short range ordering or a crystalline structure with long range ordering. Otherwise, the dust particle system will remain in a gaseous state. Many experiments have been conducted over the past decade on such complex plasmas to discover the character of the systems formed, but more work is needed to fully understand these structures. This paper describes the processes involved in setting up the CASPER GEC RF Reference Cell and the modifications necessary to examine complex plasmas. Research conducted to characterize the system is outlined to demonstrate that the CASPER Cell behaves as other GEC Cells. In addition, further research performed shows the behavior of the complex plasma system in the CASPER Cell is similar to complex plasmas studied by other groups in this field. Along the way analysis routines developed specifically for this system are described. New research involving polydisperse dust distributions is carried out in the system once the initial characterization is finished. Next, a system to externally vary the DC bias in the CASPER Cell is developed and characterized. Finally, new research conducted to specifically examine how the complex plasma system reacts to a variable DC bias is reported. Specifically, the response of the interparticle spacing to various system parameters (including the external DC bias) is examined. Also, a previously unreported phenomenon, namely layer splitting, is examined.

  8. Cell Line Data Base: structure and recent improvements towards molecular authentication of human cell lines

    PubMed Central

    Romano, Paolo; Manniello, Assunta; Aresu, Ottavia; Armento, Massimiliano; Cesaro, Michela; Parodi, Barbara

    2009-01-01

    The Cell Line Data Base (CLDB) is a well-known reference information source on human and animal cell lines including information on more than 6000 cell lines. Main biological features are coded according to controlled vocabularies derived from international lists and taxonomies. HyperCLDB (http://bioinformatics.istge.it/hypercldb/) is a hypertext version of CLDB that improves data accessibility by also allowing information retrieval through web spiders. Access to HyperCLDB is provided through indexes of biological characteristics and navigation in the hypertext is granted by many internal links. HyperCLDB also includes links to external resources. Recently, an interest was raised for a reference nomenclature for cell lines and CLDB was seen as an authoritative system. Furthermore, to overcome the cell line misidentification problem, molecular authentication methods, such as fingerprinting, single-locus short tandem repeat (STR) profile and single nucleotide polymorphisms validation, were proposed. Since this data is distributed, a reference portal on authentication of human cell lines is needed. We present here the architecture and contents of CLDB, its recent enhancements and perspectives. We also present a new related database, the Cell Line Integrated Molecular Authentication (CLIMA) database (http://bioinformatics.istge.it/clima/), that allows to link authentication data to actual cell lines. PMID:18927105

  9. Cell Line Data Base: structure and recent improvements towards molecular authentication of human cell lines.

    PubMed

    Romano, Paolo; Manniello, Assunta; Aresu, Ottavia; Armento, Massimiliano; Cesaro, Michela; Parodi, Barbara

    2009-01-01

    The Cell Line Data Base (CLDB) is a well-known reference information source on human and animal cell lines including information on more than 6000 cell lines. Main biological features are coded according to controlled vocabularies derived from international lists and taxonomies. HyperCLDB (http://bioinformatics.istge.it/hypercldb/) is a hypertext version of CLDB that improves data accessibility by also allowing information retrieval through web spiders. Access to HyperCLDB is provided through indexes of biological characteristics and navigation in the hypertext is granted by many internal links. HyperCLDB also includes links to external resources. Recently, an interest was raised for a reference nomenclature for cell lines and CLDB was seen as an authoritative system. Furthermore, to overcome the cell line misidentification problem, molecular authentication methods, such as fingerprinting, single-locus short tandem repeat (STR) profile and single nucleotide polymorphisms validation, were proposed. Since this data is distributed, a reference portal on authentication of human cell lines is needed. We present here the architecture and contents of CLDB, its recent enhancements and perspectives. We also present a new related database, the Cell Line Integrated Molecular Authentication (CLIMA) database (http://bioinformatics.istge.it/clima/), that allows to link authentication data to actual cell lines.

  10. Monitoring system and methods for a distributed and recoverable digital control system

    NASA Technical Reports Server (NTRS)

    Stange, Kent (Inventor); Hess, Richard (Inventor); Kelley, Gerald B (Inventor); Rogers, Randy (Inventor)

    2010-01-01

    A monitoring system and methods are provided for a distributed and recoverable digital control system. The monitoring system generally comprises two independent monitoring planes within the control system. The first monitoring plane is internal to the computing units in the control system, and the second monitoring plane is external to the computing units. The internal first monitoring plane includes two in-line monitors. The first internal monitor is a self-checking, lock-step-processing monitor with integrated rapid recovery capability. The second internal monitor includes one or more reasonableness monitors, which compare actual effector position with commanded effector position. The external second monitor plane includes two monitors. The first external monitor includes a pre-recovery computing monitor, and the second external monitor includes a post recovery computing monitor. Various methods for implementing the monitoring functions are also disclosed.

  11. Responsiveness Comparison of the EQ-5D, PROMIS Global Health, and VR-12 Questionnaires in Knee Arthroscopy.

    PubMed

    Oak, Sameer R; Strnad, Gregory J; Bena, James; Farrow, Lutul D; Parker, Richard D; Jones, Morgan H; Spindler, Kurt P

    2016-12-01

    The EuroQol 5 dimensions questionnaire (EQ-5D), Patient-Reported Outcomes Measurement Information System (PROMIS) 10 Global Health, and Veterans RAND 12-Item Health Survey (VR-12) are generic patient-reported outcome (PRO) questionnaires that assess a patient's general health. In choosing a PRO to track general health status, it is necessary to consider which measure will be the most responsive to change after treatment. To date, no studies exist comparing responsiveness among the EQ-5D, PROMIS 10 Global Health, and the Veterans Rand 12-Item Health Survey (VR-12). To determine which of the generic PROs are most responsive internally and externally in the setting of knee arthroscopy. Cohort study (diagnosis); Level of evidence, 3. Fifty patients who underwent knee arthroscopy were surveyed preoperatively and a mean 3.6 months postoperatively, with 90% follow-up. PROs included the EQ-5D, EQ-5D visual analog scale, PROMIS 10 Global Health (PROMIS 10) physical and mental components, VR-12 physical and mental components, and the Knee injury and Osteoarthritis Outcome Score (KOOS)-pain subscale. Internal responsiveness was evaluated by performing paired t tests on the changes in measures and calculating 2 measures of effect size: Cohen d and standardized response mean (SRM). External responsiveness was evaluated by comparing Pearson correlation measures between the disease-specific reference KOOS-pain and generic PROs. For internal responsiveness, 3 PROs showed a statistically significant improvement in score after treatment (EQ-5D: +0.10 [95% CI, 0.06-0.15], VR-12 physical: +7.2 [95% CI, 4.0-10.4]), and PROMIS 10 physical: +4.4 [95% CI, 2.6-6.3]) and effect size statistics with moderate change (Cohen d and SRM, 0.5-0.8). Assessing external responsiveness, a high correlation with the disease-specific reference (KOOS-pain score) was found for EQ-5D (0.65), VR-12 physical (0.57), and PROMIS 10 physical (0.77). For both internal and external responsiveness, the EQ-5D, VR-12 physical, and PROMIS 10 physical showed significantly greater responsiveness compared with the other general PRO measures but no statistical differences among themselves. There is no statistical difference in internal or external responsiveness to change among the EQ-5D, VR-12 physical, and PROMIS 10 physical instruments. In tracking longitudinal patient health, researchers and administrators have the flexibility to choose any of the general PROs among the EQ-5D, VR-12 physical, and PROMIS 10 physical. We recommend that any study tracking PROs in knee arthroscopy include 1 of these generic instruments.

  12. Canonical Naimark extension for generalized measurements involving sets of Pauli quantum observables chosen at random

    NASA Astrophysics Data System (ADS)

    Sparaciari, Carlo; Paris, Matteo G. A.

    2013-01-01

    We address measurement schemes where certain observables Xk are chosen at random within a set of nondegenerate isospectral observables and then measured on repeated preparations of a physical system. Each observable has a probability zk to be measured, with ∑kzk=1, and the statistics of this generalized measurement is described by a positive operator-valued measure. This kind of scheme is referred to as quantum roulettes, since each observable Xk is chosen at random, e.g., according to the fluctuating value of an external parameter. Here we focus on quantum roulettes for qubits involving the measurements of Pauli matrices, and we explicitly evaluate their canonical Naimark extensions, i.e., their implementation as indirect measurements involving an interaction scheme with a probe system. We thus provide a concrete model to realize the roulette without destroying the signal state, which can be measured again after the measurement or can be transmitted. Finally, we apply our results to the description of Stern-Gerlach-like experiments on a two-level system.

  13. Design and development of a Space Station proximity operations research and development mockup

    NASA Technical Reports Server (NTRS)

    Haines, Richard F.

    1986-01-01

    Proximity operations (Prox-Ops) on-orbit refers to all activities taking place within one km of the Space Station. Designing a Prox-Ops control station calls for a comprehensive systems approach which takes into account structural constraints, orbital dynamics including approach/departure flight paths, myriad human factors and other topics. This paper describes a reconfigurable full-scale mock-up of a Prox-Ops station constructed at Ames incorporating an array of windows (with dynamic star field, target vehicle(s), and head-up symbology), head-down perspective display of manned and unmanned vehicles, voice- actuated 'electronic checklist', computer-generated voice system, expert system (to help diagnose subsystem malfunctions), and other displays and controls. The facility is used for demonstrations of selected Prox-Ops approach scenarios, human factors research (work-load assessment, determining external vision envelope requirements, head-down and head-up symbology design, voice synthesis and recognition research, etc.) and development of engineering design guidelines for future module interiors.

  14. Online plasma calculator

    NASA Astrophysics Data System (ADS)

    Wisniewski, H.; Gourdain, P.-A.

    2017-10-01

    APOLLO is an online, Linux based plasma calculator. Users can input variables that correspond to their specific plasma, such as ion and electron densities, temperatures, and external magnetic fields. The system is based on a webserver where a FastCGI protocol computes key plasma parameters including frequencies, lengths, velocities, and dimensionless numbers. FastCGI was chosen to overcome security problems caused by JAVA-based plugins. The FastCGI also speeds up calculations over PHP based systems. APOLLO is built upon the WT library, which turns any web browser into a versatile, fast graphic user interface. All values with units are expressed in SI units except temperature, which is in electron-volts. SI units were chosen over cgs units because of the gradual shift to using SI units within the plasma community. APOLLO is intended to be a fast calculator that also provides the user with the proper equations used to calculate the plasma parameters. This system is intended to be used by undergraduates taking plasma courses as well as graduate students and researchers who need a quick reference calculation.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hechenblaikner, Gerald; Gerndt, Ruediger; Johann, Ulrich

    We describe the first investigations of the complete engineering model of the optical metrology system (OMS), a key subsystem of the LISA Pathfinder science mission to space. The latter itself is a technological precursor mission to LISA, a spaceborne gravitational wave detector. At its core, the OMS consists of four heterodyne Mach-Zehnder interferometers, a highly stable laser with an external modulator, and a phase meter. It is designed to monitor and track the longitudinal motion and attitude of two floating test masses in the optical reference frame with (relative) precision in the picometer and nanorad range, respectively. We analyze sensormore » signal correlations and determine a physical sensor noise limit. The coupling parameters between motional degrees of freedom and interferometer signals are analytically derived and compared to measurements. We also measure adverse cross-coupling effects originating from system imperfections and limitations and describe algorithmic mitigation techniques to overcome some of them. Their impact on system performance is analyzed within the context of the Pathfinder mission.« less

  16. NASA's New Thermal Management Systems Roadmap; Whats in it, What it Means

    NASA Technical Reports Server (NTRS)

    Swanson, Ted

    2016-01-01

    In July of 2015 NASA publically released a new set of Technology Area Roadmaps that will be used to help guide future NASA-funded technology development efforts. One of these was the Thermal Management Systems Roadmap, often identified as TA14. This Roadmap identifies the time sequencing and interdependencies of high priority, advanced thermal control technology for the next 5 to 20 years. Available funding limits the development of new technology. The Roadmaps are the first step in the process of prioritizing HQ-supported technology funding. The 2015 Roadmaps are focused on planned mission architectures and needs, as identified in the NRC-led science Decadals and HEOMD's Design Reference Missions. Additionally, the 2015 Roadmaps focus on "applied " R&D as opposed to more basic research. The NASA Mission Directorates were all closely involved in development of 2015 Roadmaps, and an extensive external review was also conducted. This talk will discuss the Technology Roadmaps in general, and then focus on the specific technologies identified for TA 14, Thermal Management Systems.

  17. G-autonomy of EEG recordings of psychotic patients undergoing the primitive expression form of dance therapy

    NASA Astrophysics Data System (ADS)

    Ventouras, E.-C.; Lardi, I.; Dimitriou, S.; Margariti, A.; Chondraki, P.; Kalatzis, I.; Economou, N.-T.; Tsekou, H.; Paparrigopoulos, T.; Ktonas, P. Y.

    2015-09-01

    Primitive expression (PE) is a form of dance therapy (DT) that involves an interaction of ethologically and socially based forms which are supplied for re-enactment. Brain connectivity has been measured in electroencephalographic (EEG) data of patients with schizophrenia undergoing PE DT, using the correlation coefficient and mutual information. These parameters do not measure the existence or absence of directionality in the connectivity. The present study investigates the use of the G-autonomy measure of EEG electrode voltages of the same group of schizophrenic patients. G-autonomy is a measure of the “autonomy” of a system. It indicates the degree by which prediction of the system's future evolution is enhanced by taking into account its own past states, in comparison to predictions based on past states of a set of external variables. In the present research, “own” past states refer to voltage values in the time series recorded at a specific electrode and “external” variables refer to the voltage values recorded at other electrodes. Indication is provided for an acute effect of early-stage PE DT expressed by the augmentation of G-autonomy in the delta rhythm and an acute effect of late- stage PE DT expressed by the reduction of G-autonomy in the theta and alpha rhythms.

  18. [Evidence-based management of medical disposable materials].

    PubMed

    Yang, Hai

    2009-03-01

    Evidence-based management of medical disposable materials pays attention to collect evidence comprehensively and systematically, accumulate and create evidence through its own work and also evaluate evidence strictly. This can be used as a function to guide out job. Medical disposable materials evidence system contains product register qualification, product quality certification, supplier's behavior, internal and external communication evidence. Managers can find different ways in creating and using evidence referring to specific inside and outside condition. Evidence-based management can help accelerating the development of management of medical disposable materials from traditional experience pattern to a systematic and scientific pattern. It also has the very important meaning to improve medical quality, control the unreasonable growth of medical expense and make purchase and supply chain be more efficient.

  19. Archiving data from new survey technologies: Enabling research with high-precision data while preserving participant privacy

    DOE PAGES

    Gonder, Jeffrey; Burton, Evan; Murakami, Elaine

    2015-12-29

    Despite the significant effort and expense to collect high-resolution Global Positioning System (GPS) data in travel surveys, privacy concerns often lead to its underutilization. This paper describes development of the Transportation Secure Data Center (TSDC) to address this dilemma of providing data access while preserving privacy. Furthermore, the TSDC operating structure was developed in consultation with an advisory committee and includes: a secure enclave with no external access for backing up and processing raw data, a publicly accessible website for downloading cleansed data, and a secure portal environment through which approved users can work with detailed spatial data using amore » variety of tools and reference information.« less

  20. Metamaterial split ring resonator as a sensitive mechanical vibration sensor

    NASA Astrophysics Data System (ADS)

    Sikha Simon, K.; Chakyar, Sreedevi P.; Andrews, Jolly; Joseph V., P.

    2017-06-01

    This paper introduces a sensitive vibration sensor based on microwave metamaterial Split Ring Resonator (SRR) capable of detecting any ground vibration. The experimental setup consists of single Broad-side Coupled SRR (BCSRR) unit fixed on a cantilever capable of sensitive vibrations. It is arranged between transmitting and receiving probes of a microwave measurement system. The absorption level variations at the resonant frequency due to the displacement from the reference plane of SRR, which is a function of the strength of external mechanical vibration, is analyzed. This portable and cost effective sensor working on a single frequency is observed to be capable of detecting even very weak vibrations. This may find potential applications in the field of tamper-proofing, mining, quarrying and earthquake sensing.

  1. Free-space QKD system hacking by wavelength control using an external laser.

    PubMed

    Lee, Min Soo; Woo, Min Ki; Jung, Jisung; Kim, Yong-Su; Han, Sang-Wook; Moon, Sung

    2017-05-15

    We develop a way to hack free-space quantum key distribution (QKD) systems by changing the wavelength of the quantum signal laser using an external laser. Most free-space QKD systems use four distinct lasers for each polarization, thereby making the characteristics of each laser indistinguishable. We also discover a side-channel that can distinguish the lasers by using an external laser. Our hacking scheme identifies the lasers by automatically applying the external laser to each signal laser at different intensities and detecting the wavelength variation according to the amount of incident external laser power. We conduct a proof-of-principle experiment to verify the proposed hacking structure and confirm that the wavelength varies by several gigahertzes to several nanometers, depending on the intensity of the external laser. The risk of hacking is successfully proven through the experimental results. Methods for prevention are also suggested.

  2. Some engineering aspects of insulin delivery systems.

    PubMed

    Spencer, W J; Bair, R E; Carlson, G A; Love, J T; Urenda, R S; Eaton, R P; Schade, D S

    1980-01-01

    The characteristics of electronically controlled insulin delivery systems are presented. Early experiments with an external system have shown promise in providing improved glycemic control over conventional methods of single or multiple subcutaneous insulin injections. The encouraging results with external insulin delivery systems have led to the development and early testing in dogs of an implantable system with remote controls to permit variable insulin flow rates. A number of questions remain to be answered before widespread experimentation with external and implanted insulin delivery systems is possible. There appears to be no major development problems with the engineering aspects of such systems.

  3. Normative growth data for the external diameters of the external and internal iliac arteries in human fetuses--an anatomical, digital and statistical study.

    PubMed

    Szpinda, Michał; Szpinda, Anna

    2012-01-01

    Normative data on the diameters of the aorto-iliac segment are extremely useful in the diagnosis and monitoring of prenatal arterial variants and pathologies. The present study describes age-specific reference intervals and normal growth curves for the external diameters of the external and internal iliac arteries. Using anatomical dissection and digital-image analysis, the normal growth of the external diameters of the external and internal iliac arteries was studied in 124 spontaneously aborted human fetuses, aged 15-34 weeks. Neither sex differences nor laterality differences were found. The external diameters of the external iliac arteries increased from 0.31 +/- 0.06 to 1.41 +/- 0.31 mm on the right, and from 0.29 +/- 0.04 to 1.37 +/- 0.24 mm on the left, and generated the following growth curves of best fit: y = 0.665 - 0.056 x Age + 0.002 x Age2 +/- 0.143 (R2 = 0.82) and y = 0.612 - 0.052 x Age + 0.002 x Age2 +/- 0.118 (R2 = 0.86), respectively. The external diameters of the internal iliac arteries were found to be statistically larger than those of the external iliac arteries (p = 0.0000). The external diameters of the internal iliac arteries ranged from 0.44 +/- 0.07 to 2.04 +/- 0.43 mm on the right, and from 0.44 +/- 0.06 to 1.83 +/- 0.43 mm on the left, and modeled the following quadratic functions: y = 1.524 - 0.127 x Age + 0.004 x Age2 +/- 0.242 (R2 = 0.74), and y = 1.391 - 0.117 x Age + 0.004 x Age2 +/- 0.220 (R2 = 0.76), respectively. The right external iliac arteries (in 71% of the cases) and the right internal iliac arteries (in 65.3% of cases) were larger in external diameter. The values of the external diameters of the external and internal iliac arteries are independent of sex. A strong trend towards higher values for the right external and internal iliac arteries is noted. The external diameter of the internal iliac artery is nearly 1.5 times greater than that of the external iliac artery. Surprisingly, normal growth of the external diameters of the external and internal iliac arteries follows quadratic functions.

  4. A Proposal of a Method to Measure and Evaluate the Effect to Apply External Support Measures for Owners by Construction Management Method, etc

    NASA Astrophysics Data System (ADS)

    Tada, Hiroshi; Miyatake, Ichiro; Mouri, Junji; Ajiki, Norihiko; Fueta, Toshiharu

    In Japan, various approaches have been taken to ensure the quality of public works or to support the procurement regime of the governmental agencies, as a means to utilize external resources, which include the procurement support service or the construction management (CM) method. Although discussions on these measures to utilize external resources (hereinafter referred to as external support measure) have been going on, as well as the follow-up surveys showing the positive effects of such measures have been conducted, the surveys only deal with the matters concerning the overall effects of the external support measure on the whole, meaning that the effect of each item of the tasks have not been addressed, and that the extent it dealt with the expectations of the client is unknown. However, the effective use of the external support measure in future cannot be achieved without knowing what was the purpose to introduce the external support measure, and what effect was expected on each task item, and what extent the expectation fulfilled. Furthermore, it is important to clarify not only the effect as compared to the client's expectation (performance), but also the public benefit of this measure (value improvement). From this point of view, there is not an established method to figure out the effect of the client's measure to utilize external resources. In view of this background, this study takes the CM method as an example of the external support measure, and proposes a method to measure and evaluate the effect by each task item, and suggests the future issues and possible responses, in the aim of contributing the promotion, improvement, and proper implementation of the external support measures in future.

  5. Destination memory in Alzheimer's Disease: when I imagine telling Ronald Reagan about Paris.

    PubMed

    El Haj, Mohamad; Postal, Virginie; Allain, Philippe

    2013-01-01

    Destination memory refers to remembering the destination of information that people output. This present paper establishes a new distinction between external and internal processes within this memory system for both normal aging and Alzheimer's Disease (AD). Young adults, older adults, and mild AD patients were asked either to tell facts (i.e., external destination memory condition) or to imagine telling facts (i.e., internal destination memory condition) to pictures of famous people. The experiment established three major findings. First, the destination memory performance of the AD patients was significantly poorer than that of older adults, which in turn was poorer than that of the young adults. Furthermore, internal destination processes were more prone to being forgotten than external destination memory processes. In other words, participants had more difficulty in remembering whether they had previously imagined telling the facts to the pictures or not (i.e., imagined condition) than in remembering whether they had previously told the facts to the pictures or not (i.e., enacted condition). Second, significant correlations were detected between performances on destination memory and several executive measures such as the Stroop, the Plus-Minus and the Binding tasks. Third, among the executive measures, regression analyses showed that performance on the Stroop task was a main factor in explaining variance in destination memory performance. Our findings reflect the difficulty in remembering the destination of internally generated information. They also demonstrate the involvement of inhibitory processes in destination memory. Copyright © 2011 Elsevier Ltd. All rights reserved.

  6. Breaking the Silos: The art Documentation Suite

    NASA Astrophysics Data System (ADS)

    Kutschke, Robert K.

    2015-12-01

    The art event-processing framework is used by almost all new experiments at Fermilab, and by several outside of Fermilab. All use art as an external product in the same sense that the compiler, ROOT, Geant4, CLHEP and boost are external products. The art team has embarked on a campaign to document art and develop training materials for new users. Many new users of art have little or no knowledge of C++, software engineering, build systems or the many external packages used by art or their experiments, such as ROOT, CLHEP, HEPPDT, and boost. To effectively teach art requires that the training materials include appropriate introductions to these topics as they are encountered. Experience has shown that simply referring readers to the existing native documentation does not work; too often a simple idea that they need to understand is described in a context that presumes prerequisites that are unimportant for a beginning user of art. There is the additional complication that the training materials must be presented in a way that does not presume knowledge of any of the experiments using art. Finally, new users of art arrive at random times throughout the year and the training materials must allow them to start to learn art at any time. This presentation will explain the strategies adopted by the art team to develop a documentation suite that complies with these boundary conditions. It will also show the present status of the documentation suite, including feedback the art team has received from pilot users.

  7. 40 CFR 1065.307 - Linearity verification.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... meter at different flow rates. Use a gravimetric reference measurement (such as a scale, balance, or... nitrogen. Select gas divisions that you typically use. Use a selected gas division as the measured value.... For linearity verification for gravimetric PM balances, use external calibration weights that that...

  8. 40 CFR 1065.307 - Linearity verification.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... meter at different flow rates. Use a gravimetric reference measurement (such as a scale, balance, or... nitrogen. Select gas divisions that you typically use. Use a selected gas division as the measured value.... For linearity verification for gravimetric PM balances, use external calibration weights that that...

  9. IRIS TOXICOLOGICAL REVIEW OF DECABROMODIPHENYL ETHER (EXTERNAL REVIEW DRAFT)

    EPA Science Inventory

    The U.S. EPA is conducting a peer review of the scientific basis supporting the human health hazard and dose-response assessments of congeners of polybrominated diphenyl ethers (PDBEs), this review is about Decabromodiphenyl Ether, or commonly referred to as decaBDE (BDE-209). ...

  10. AIR QUALITY CRITERIA FOR LEAD (SECOND EXTERNAL REVIEW DRAFT)

    EPA Science Inventory

    The Clean Air Act mandates periodic review of the National Ambient Air Quality Standards (NAAQS) for six common air pollutants, also referred to as criteria pollutants, including lead. Under the review process, EPA's Office of Research and Development develops a criteria docu...

  11. 12 CFR 615.5201 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... “reference asset.” Credit-enhancing interest-only strip— (1) The term credit-enhancing interest-only strip...-only strip, FCA will consider the economic substance of the transaction. Credit-enhancing... its own right and carries such loan or lease assets on its books. Externally rated means that an...

  12. Flare angles measured with ball gage

    NASA Technical Reports Server (NTRS)

    Cleghorn, D.; Wall, W. A.

    1968-01-01

    Precision tungsten carbide balls measure the internal angle of flared joints. Measurements from small and large balls in the flare throat to an external reference point are made. The difference in distances and diameters determine the average slope of the flare between the points of ball contact.

  13. 41 CFR 60-300.44 - Required contents of affirmative action programs.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... protected veteran. (f) External dissemination of policy, outreach and positive recruitment—(1) Required outreach efforts. (i) The contractor shall undertake appropriate outreach and positive recruitment... outreach and positive recruitment activities referred to in paragraph (f)(1) of this section. This is an...

  14. Organisational Career Management in Israel.

    ERIC Educational Resources Information Center

    Tzabbar, Daniel; Vardi, Yoav; Baruch, Yehuda

    2003-01-01

    Responses from human resource managers in 136 Israeli companies revealed a paternalistic approach to career management. Promotion decisions depended on individual rather than universal criteria and internal human resource development. They were more likely to hire managers from external rather than internal sources. (Contains 44 references.) (SK)

  15. DNA DAMAGE AND EXTERNAL LESIONS IN BROWN BULLHEADS FROM CONTAMINATED HABITATS

    EPA Science Inventory

    The Comet assay was used to compare levels of DNA damage in brown bullheads (Ameiurus nebulosus) collected from three known contaminated locations, the Cuyahoga River, Ashtabula River, and Ashumet Pond (Cape Cod), with brown bullheads collected from three paired reference sites, ...

  16. Motivations and contents of parent-child value transmission.

    PubMed

    Barni, Daniela; Donato, Silvia; Rosnati, Rosa; Danioni, Francesca

    2017-01-01

    This study focused on parents' motivations to transmit values to their adolescent children. According to Self-Determination Theory, controlled motivations (i.e., external and introjected)-which refer to doing something because it leads to approval or rewards-and autonomous motivations (i.e., identified and integrated)-which refer to doing something because it is perceived as inherently worthy-were examined. 325 Italian parental couples, with one child aged between 14 and 18 years, filled out a self-report questionnaire. Results showed that in value transmission, both parents were primarily moved by autonomous motivations, although for fathers, external motivations were more important than for mothers. Both paternal and maternal motivations resulted to be related with the values parents would like their children to endorse. In particular, the more parents felt volitional in transmitting values, the more they gave importance to self-transcendence in their children's socialization; the more parents were guided by controlled motivations, the more they would like their children to endorse conservation values. Implications of this research and its possible developments are discussed.

  17. Fast quantification of bovine milk proteins employing external cavity-quantum cascade laser spectroscopy.

    PubMed

    Schwaighofer, Andreas; Kuligowski, Julia; Quintás, Guillermo; Mayer, Helmut K; Lendl, Bernhard

    2018-06-30

    Analysis of proteins in bovine milk is usually tackled by time-consuming analytical approaches involving wet-chemical, multi-step sample clean-up procedures. The use of external cavity-quantum cascade laser (EC-QCL) based IR spectroscopy was evaluated as an alternative screening tool for direct and simultaneous quantification of individual proteins (i.e. casein and β-lactoglobulin) and total protein content in commercial bovine milk samples. Mid-IR spectra of protein standard mixtures were used for building partial least squares (PLS) regression models. A sample set comprising different milk types (pasteurized; differently processed extended shelf life, ESL; ultra-high temperature, UHT) was analysed and results were compared to reference methods. Concentration values of the QCL-IR spectroscopy approach obtained within several minutes are in good agreement with reference methods involving multiple sample preparation steps. The potential application as a fast screening method for estimating the heat load applied to liquid milk is demonstrated. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. Shearing-induced asymmetry in entorhinal grid cells.

    PubMed

    Stensola, Tor; Stensola, Hanne; Moser, May-Britt; Moser, Edvard I

    2015-02-12

    Grid cells are neurons with periodic spatial receptive fields (grids) that tile two-dimensional space in a hexagonal pattern. To provide useful information about location, grids must be stably anchored to an external reference frame. The mechanisms underlying this anchoring process have remained elusive. Here we show in differently sized familiar square enclosures that the axes of the grids are offset from the walls by an angle that minimizes symmetry with the borders of the environment. This rotational offset is invariably accompanied by an elliptic distortion of the grid pattern. Reversing the ellipticity analytically by a shearing transformation removes the angular offset. This, together with the near-absence of rotation in novel environments, suggests that the rotation emerges through non-coaxial strain as a function of experience. The systematic relationship between rotation and distortion of the grid pattern points to shear forces arising from anchoring to specific geometric reference points as key elements of the mechanism for alignment of grid patterns to the external world.

  19. Spatiotemporal Patterns of the Use of Urban Green Spaces and External Factors Contributing to Their Use in Central Beijing

    PubMed Central

    Li, Fangzheng; Zhang, Fen; Li, Xiong; Wang, Peng; Liang, Junhui; Mei, Yuting; Cheng, Wenwen; Qian, Yun

    2017-01-01

    Urban green spaces encourage outdoor activity and social communication that contribute to the health of local residents. Examining the relationship between the use of urban green spaces and factors influencing their utilization can provide essential references for green space site selection in urban planning. In contrast to previous studies that focused on internal factors, this study highlights the external factors (traffic convenience, population density and commercial facilities) contributing to the use of urban green spaces. We conducted a spatiotemporal analysis of the distribution of visitors in 208 selected green spaces in central Beijing. We examined the relationship between the spatial pattern of visitor distribution within urban green spaces and external factors, using the Gini coefficient, kernel density estimation, and geographical detectors. The results of the study were as follows. The spatial distribution of visitors within central Beijing’s green spaces was concentrated, forming different agglomerations. The three examined external factors are all associated with the use of green spaces. Among them, commercial facilities are the important external factor associated with the use of green spaces. For the selection of sites for urban green spaces, we recommend consideration of external factors in order to balance urban green space utilization. PMID:28264451

  20. Spatiotemporal Patterns of the Use of Urban Green Spaces and External Factors Contributing to Their Use in Central Beijing.

    PubMed

    Li, Fangzheng; Zhang, Fen; Li, Xiong; Wang, Peng; Liang, Junhui; Mei, Yuting; Cheng, Wenwen; Qian, Yun

    2017-02-27

    Urban green spaces encourage outdoor activity and social communication that contribute to the health of local residents. Examining the relationship between the use of urban green spaces and factors influencing their utilization can provide essential references for green space site selection in urban planning. In contrast to previous studies that focused on internal factors, this study highlights the external factors (traffic convenience, population density and commercial facilities) contributing to the use of urban green spaces. We conducted a spatiotemporal analysis of the distribution of visitors in 208 selected green spaces in central Beijing. We examined the relationship between the spatial pattern of visitor distribution within urban green spaces and external factors, using the Gini coefficient, kernel density estimation, and geographical detectors. The results of the study were as follows. The spatial distribution of visitors within central Beijing's green spaces was concentrated, forming different agglomerations. The three examined external factors are all associated with the use of green spaces. Among them, commercial facilities are the important external factor associated with the use of green spaces. For the selection of sites for urban green spaces, we recommend consideration of external factors in order to balance urban green space utilization.

  1. The Amsterdam wrist rules: the multicenter prospective derivation and external validation of a clinical decision rule for the use of radiography in acute wrist trauma.

    PubMed

    Walenkamp, Monique M J; Bentohami, Abdelali; Slaar, Annelie; Beerekamp, M Suzan H; Maas, Mario; Jager, L Cara; Sosef, Nico L; van Velde, Romuald; Ultee, Jan M; Steyerberg, Ewout W; Goslings, J Carel; Schep, Niels W L

    2015-12-18

    Although only 39 % of patients with wrist trauma have sustained a fracture, the majority of patients is routinely referred for radiography. The purpose of this study was to derive and externally validate a clinical decision rule that selects patients with acute wrist trauma in the Emergency Department (ED) for radiography. This multicenter prospective study consisted of three components: (1) derivation of a clinical prediction model for detecting wrist fractures in patients following wrist trauma; (2) external validation of this model; and (3) design of a clinical decision rule. The study was conducted in the EDs of five Dutch hospitals: one academic hospital (derivation cohort) and four regional hospitals (external validation cohort). We included all adult patients with acute wrist trauma. The main outcome was fracture of the wrist (distal radius, distal ulna or carpal bones) diagnosed on conventional X-rays. A total of 882 patients were analyzed; 487 in the derivation cohort and 395 in the validation cohort. We derived a clinical prediction model with eight variables: age; sex, swelling of the wrist; swelling of the anatomical snuffbox, visible deformation; distal radius tender to palpation; pain on radial deviation and painful axial compression of the thumb. The Area Under the Curve at external validation of this model was 0.81 (95 % CI: 0.77-0.85). The sensitivity and specificity of the Amsterdam Wrist Rules (AWR) in the external validation cohort were 98 % (95 % CI: 95-99 %) and 21 % (95 % CI: 15 %-28). The negative predictive value was 90 % (95 % CI: 81-99 %). The Amsterdam Wrist Rules is a clinical prediction rule with a high sensitivity and negative predictive value for fractures of the wrist. Although external validation showed low specificity and 100 % sensitivity could not be achieved, the Amsterdam Wrist Rules can provide physicians in the Emergency Department with a useful screening tool to select patients with acute wrist trauma for radiography. The upcoming implementation study will further reveal the impact of the Amsterdam Wrist Rules on the anticipated reduction of X-rays requested, missed fractures, Emergency Department waiting times and health care costs. This study was registered in the Dutch Trial Registry, reference number NTR2544 on October 1(st), 2010.

  2. [Research and Design of a System for Detecting Automated External Defbrillator Performance Parameters].

    PubMed

    Wang, Kewu; Xiao, Shengxiang; Jiang, Lina; Hu, Jingkai

    2017-09-30

    In order to regularly detect the performance parameters of automated external defibrillator (AED), to make sure it is safe before using the instrument, research and design of a system for detecting automated external defibrillator performance parameters. According to the research of the characteristics of its performance parameters, combing the STM32's stability and high speed with PWM modulation control, the system produces a variety of ECG normal and abnormal signals through the digital sampling methods. Completed the design of the hardware and software, formed a prototype. This system can accurate detect automated external defibrillator discharge energy, synchronous defibrillation time, charging time and other key performance parameters.

  3. Method for refreshing a non-volatile memory

    DOEpatents

    Riekels, James E.; Schlesinger, Samuel

    2008-11-04

    A non-volatile memory and a method of refreshing a memory are described. The method includes allowing an external system to control refreshing operations within the memory. The memory may generate a refresh request signal and transmit the refresh request signal to the external system. When the external system finds an available time to process the refresh request, the external system acknowledges the refresh request and transmits a refresh acknowledge signal to the memory. The memory may also comprise a page register for reading and rewriting a data state back to the memory. The page register may comprise latches in lieu of supplemental non-volatile storage elements, thereby conserving real estate within the memory.

  4. Measurement of superficial and deep abdominal muscle thickness: an ultrasonography study.

    PubMed

    Tahan, Nahid; Khademi-Kalantari, Khosro; Mohseni-Bandpei, Mohammad Ali; Mikaili, Saeed; Baghban, Alireza Akbarzadeh; Jaberzadeh, Shapour

    2016-08-23

    Real-time ultrasound imaging is a valid method in the field of rehabilitation. The ultrasound imaging allows direct visualization for real-time study of the muscles as they contract over the time. Measuring of the size of each abdominal muscle in relation to the others provides useful information about the differences in structure, as well as data on trunk muscle activation patterns. The purpose of this study was to assess the size and symmetry of the abdominal muscles at rest in healthy adults and to provide a reference range of absolute abdominal muscle size in a relatively large population. A total 156 healthy subjects with the age range of 18-44 years were randomly recruited. The thickness of internal oblique, external oblique, transverse abdominis, and rectus abdominis muscles was measured at rest on both right and left sides using ultrasound. Independent t test was used to compare the mean thickness of each abdominal muscle between males and females. Differences on side-to-side thicknesses were assessed using paired t test. The association between abdominal muscle thicknesses with gender and anthropometric variables was examined using the Pearson correlation coefficient. A normal pattern of increasing order of mean abdominal muscle thickness was found in both genders at both right and left sides: transverse abdominis < external oblique < internal oblique < rectus abdominis. There was a significant difference on the size of transverse abdominis, internal oblique, and external oblique muscles between right and left sides in both genders. Males had significantly thicker abdominal muscles than females. Age was significantly correlated with the thickness of internal oblique, external oblique, and rectus abdominis muscles. Body mass index was also positively correlated with muscle thickness of rectus abdominis and external oblique. The results provide a normal reference range for the abdominal muscles in healthy subjects and may be used as an index to find out abnormalities and also to evaluate the effectiveness of different interventions.

  5. Neural evidence for Reference-dependence in real-market-transactions.

    PubMed

    Weber, Bernd; Aholt, Andreas; Neuhaus, Carolin; Trautner, Peter; Elger, Christian E; Teichert, Thorsten

    2007-03-01

    Human decision making has become one of the major research-foci in economics, marketing and in neuroscience. This study integrates perspectives from these disciplines by examining neurophysiological correlates to Reference-dependence of utility evaluations in real market contexts both before and after choice. First, by comparing buying and selling decisions, we observe an activation of the amygdala only in the latter. We interpret this as loss aversion with respect to prior possessions. This finding contributes to the settling of an ongoing fundamental dispute in economic theory by indicating the absence of loss aversion for money in routine transactions. Second, ex post satisfaction statements are accompanied by an activation of the reward processing orbitofrontal cortex, if the evaluation context is framed by a high external reference price instead of a lower internal reference price. This indicates a nonrational Reference-dependence--despite the neoclassical view of a rational Homo Economicus--of satisfaction measures and challenges a central marketing variable.

  6. Cycling through the Blues: The Impact of Systemic External Stressors on Student Mental States and Symptoms of Depression

    ERIC Educational Resources Information Center

    Goldring, Michelle A.

    2012-01-01

    This study seeks to find if the structure of the demands of the quarter system impacts the levels of depression reported in the school's student body. That is, can the external and systemic stressors at be linked to levels of depressive symptoms? This study proposes that depressive symptoms may be linked to external stresses exerted on the student…

  7. Mechanical design of the University of Florida Torsion Pendulum for testing the LISA Gravitational Reference Sensor

    NASA Astrophysics Data System (ADS)

    Shelley, Ryan; Chilton, Andrew; Olatunde, Tawio; Ciani, Giacomo; Mueller, Guido; Conklin, John

    2014-03-01

    The Laser Interferometer Space Antenna (LISA) requires free falling test masses, whose acceleration must be below 3 fm/s2/rtHz in the lower part of LISA's frequency band ranging from 0.1 to 100 mHz. Gravitational reference sensors (GRS) house the test masses, shield them from external disturbances, control their orientation, and sense their position at the nm/rtHz level. The GRS torsion pendulum is a laboratory test bed for GRS technology. By decoupling the system of test masses from the gravity of the Earth, it is possible to identify and quantify many sources of noise in the sensor. The mechanical design of the pendulum is critical to the study of the noise sources and the development of new technologies that can improve performance and reduce cost. The suspended test mass is a hollow, gold-coated, aluminum cube which rests inside a gold-coated, aluminum housing with electrodes for sensing and actuating all six degrees of freedom. This poster describes the design, analysis, and assembly of the mechanical subsystems of the UF Torsion Pendulum.

  8. PROTEUS two-dimensional Navier-Stokes computer code, version 1.0. Volume 3: Programmer's reference

    NASA Technical Reports Server (NTRS)

    Towne, Charles E.; Schwab, John R.; Benson, Thomas J.; Suresh, Ambady

    1990-01-01

    A new computer code was developed to solve the 2-D or axisymmetric, Reynolds-averaged, unsteady compressible Navier-Stokes equations in strong conservation law form. The thin-layer or Euler equations may also be solved. Turbulence is modeled using an algebraic eddy viscosity model. The objective was to develop a code for aerospace applications that is easy to use and easy to modify. Code readability, modularity, and documentation were emphasized. The equations are written in nonorthogonal body-fitted coordinates, and solved by marching in time using a fully-coupled alternating-direction-implicit procedure with generalized first- or second-order time differencing. All terms are linearized using second-order Taylor series. The boundary conditions are treated implicitly, and may be steady, unsteady, or spatially periodic. Simple Cartesian or polar grids may be generated internally by the program. More complex geometries require an externally generated computational coordinate system. The documentation is divided into three volumes. Volume 3 is the Programmer's Reference, and describes the program structure, the FORTRAN variables stored in common blocks, and the details of each subprogram.

  9. On The Computational Capabilities of Physical Systems. Part 2; Relationship With Conventional Computer Science

    NASA Technical Reports Server (NTRS)

    Wolpert, David H.; Koga, Dennis (Technical Monitor)

    2000-01-01

    In the first of this pair of papers, it was proven that there cannot be a physical computer to which one can properly pose any and all computational tasks concerning the physical universe. It was then further proven that no physical computer C can correctly carry out all computational tasks that can be posed to C. As a particular example, this result means that no physical computer that can, for any physical system external to that computer, take the specification of that external system's state as input and then correctly predict its future state before that future state actually occurs; one cannot build a physical computer that can be assured of correctly "processing information faster than the universe does". These results do not rely on systems that are infinite, and/or non-classical, and/or obey chaotic dynamics. They also hold even if one uses an infinitely fast, infinitely dense computer, with computational powers greater than that of a Turing Machine. This generality is a direct consequence of the fact that a novel definition of computation - "physical computation" - is needed to address the issues considered in these papers, which concern real physical computers. While this novel definition does not fit into the traditional Chomsky hierarchy, the mathematical structure and impossibility results associated with it have parallels in the mathematics of the Chomsky hierarchy. This second paper of the pair presents a preliminary exploration of some of this mathematical structure. Analogues of Chomskian results concerning universal Turing Machines and the Halting theorem are derived, as are results concerning the (im)possibility of certain kinds of error-correcting codes. In addition, an analogue of algorithmic information complexity, "prediction complexity", is elaborated. A task-independent bound is derived on how much the prediction complexity of a computational task can differ for two different reference universal physical computers used to solve that task, a bound similar to the "encoding" bound governing how much the algorithm information complexity of a Turing machine calculation can differ for two reference universal Turing machines. Finally, it is proven that either the Hamiltonian of our universe proscribes a certain type of computation, or prediction complexity is unique (unlike algorithmic information complexity), in that there is one and only version of it that can be applicable throughout our universe.

  10. European consensus conference for external quality assessment in molecular pathology.

    PubMed

    van Krieken, J H; Siebers, A G; Normanno, N

    2013-08-01

    Molecular testing of tumor samples to guide treatment decisions is of increasing importance. Several drugs have been approved for treatment of molecularly defined subgroups of patients, and the number of agents requiring companion diagnostics for their prescription is expected to rapidly increase. The results of such testing directly influence the management of individual patients, with both false-negative and false-positive results being harmful for patients. In this respect, external quality assurance (EQA) programs are essential to guarantee optimal quality of testing. There are several EQA schemes available in Europe, but they vary in scope, size and execution. During a conference held in early 2012, medical oncologists, pathologists, geneticists, molecular biologists, EQA providers and representatives from pharmaceutical industries developed a guideline to harmonize the standards applied by EQA schemes in molecular pathology. The guideline comprises recommendations on the organization of an EQA scheme, defining the criteria for reference laboratories, requirements for EQA test samples and the number of samples that are needed for an EQA scheme. Furthermore, a scoring system is proposed and consequences of poor performance are formulated. Lastly, the contents of an EQA report, communication of the EQA results, EQA databases and participant manual are given.

  11. Diagnosis and subtypes of adolescent antisocial personality disorder.

    PubMed

    Jones, Meredith; Westen, Drew

    2010-04-01

    The present study examined the application of the Antisocial Personality Disorder (APD) diagnosis to adolescents and investigated the possibility of subtypes of APD adolescents. As part of a broader study of adolescent personality in clinically-referred patients, experienced clinicians provided personality data on a randomly selected patient in their care using the SWAP-II-A personality pathology instrument. Three hundred thirteen adolescents met adult DSM-IV diagnostic criteria for APD. To characterize adolescents with the disorder, we aggregated the data to identify the items most descriptive and distinctive of APD adolescents relative to other teenagers in the sample (N = 950). Q-factor analysis identified five personality subtypes: psychopathic-like, socially withdrawn, impulsive-histrionic, emotionally dysregulated, and attentionally dysregulated. The five subtypes differed in predictable ways on a set of external criteria related to global adaptive functioning, childhood family environment, and family history of psychiatric illness. Both the APD diagnosis and the empirically derived APD subtypes provided incremental validity over and above the DSM-IV disruptive behavior disorders in predicting global adaptive functioning, number of arrests, early-onset severe externalizing pathology, and quality of peer relationships. Although preliminary, these results provide support for the use of both APD and personality-based subtyping systems in adolescents.

  12. Electrotonic potentials in Aloe vera L.: Effects of intercellular and external electrodes arrangement.

    PubMed

    Volkov, Alexander G; Nyasani, Eunice K; Tuckett, Clayton; Scott, Jessenia M; Jackson, Mariah M Z; Greeman, Esther A; Greenidge, Ariane S; Cohen, Devin O; Volkova, Maia I; Shtessel, Yuri B

    2017-02-01

    Electrostimulation of plants can induce plant movements, activation of ion channels, ion transport, gene expression, enzymatic systems activation, electrical signaling, plant-cell damage, enhanced wound healing, and influence plant growth. Here we found that electrical networks in plant tissues have electrical differentiators. The amplitude of electrical responses decreases along a leaf and increases by decreasing the distance between polarizing Pt-electrodes. Intercellular Ag/AgCl electrodes inserted in a leaf and extracellular Ag/AgCl electrodes attached to the leaf surface were used to detect the electrotonic potential propagation along a leaf of Aloe vera. There is a difference in duration and amplitude of electrical potentials measured by electrodes inserted in a leaf and those attached to a leaf's surface. If the external reference electrode is located in the soil near the root, it changes the amplitude and duration of electrotonic potentials due to existence of additional resistance, capacitance, ion channels and ion pumps in the root. The information gained from this study can be used to elucidate extracellular and intercellular communication in the form of electrical signals within plants. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Flow cytometry reliability analysis and variations in sugarcane DNA content.

    PubMed

    Oliveira, A C L; Pasqual, M; Bruzi, A T; Pio, L A S; Mendonça, P M S; Soares, J D R

    2015-06-29

    The aim of this study was to evaluate the reliability of flow cytometry analysis and the use of this technique to differentiate species and varieties of sugarcane (Saccharum spp) according to their relative DNA content. We analyzed 16 varieties and three species belonging to this genus. To determine a reliable protocol, we evaluated three extraction buffers (LB01, Marie, and Tris·MgCl2), the presence and absence of RNase, six doses of propidium iodide (10, 15, 20, 25, and 30 μg), four periods of exposure to propidium iodide (0, 5, 10, and 20 min), and seven external reference standards (peas, beans, corn, radish, rye, soybean, and tomato) with reference to the coefficient of variation and the DNA content. For statistical analyses, we used the programs Sisvar(®) and Xlstat(®). We recommend using the Marie extraction buffer and at least 15 μg propidium iodide. The samples should not be analyzed immediately after the addition of propidium iodide. The use of RNase is optional, and tomato should be used as an external reference standard. The results show that sugarcane has a variable genome size (8.42 to 12.12 pg/2C) and the individuals analyzed could be separated into four groups according to their DNA content with relative equality in the genome sizes of the commercial varieties.

  14. Analysis of posture and eye movement responses to Coriolis stimulation under 1 G and microgravity conditions.

    PubMed

    Sekine, Motoki; Takahashi, Masahiro; Iida, Masahiro

    2009-12-20

    To detect the effect of microgravity on vestibular responses, we conducted Coriolis stimulation experiments at 1 G and μ G. Five men with vision occluded were asked to tilt their head forward while rotating at 100 degrees/sec. Postural changes were recorded by a 3D linear accelerometer, and the distance of upper body movement was derived from recordings of linear acceleration. Eye movements were recorded by a CCD camera. For a second period after commencing head tilt, the upper body moved 10 cm in the direction of inertia input at 1 G, but it moved to the opposite direction at μ G, i.e., 4 cm in the direction of inertia force. Nystagmus peak slow-phase velocity immediately after head tilt and its attenuation process did not differ between 1 G and μ G. The strength of movement sensation and the severity of motion sickness were far weaker at μ G than at 1 G. It was concluded that inertia input is valid to induce postural and sensation responses only when the external reference is given Z axis by gravity. Vestibular ocular response may be maintained at μ G because the head reference is valid even after the external reference becomes arbitrary.

  15. A survey of coagulation laboratory practices and satisfaction ratings of member laboratories of the Thailand National External Quality Assessment Scheme for blood coagulation.

    PubMed

    Chuntarut, A; Tientadakul, P; Wongkrajang, P

    2016-06-01

    The Thailand National External Quality Assessment Scheme (NEQAS) for blood coagulation was established in 2005. The objective of this study was to collect data of coagulation laboratory practices and satisfaction of NEQAS member. Two hundred seventy-six questionnaires were sent to laboratories that are members of NEQAS to obtain data relating to coagulation laboratory practice and satisfaction in 2014. Data from this survey were compared with data from the survey conducted in 2005 to evaluate levels of improvement. Of 276 questionnaires sent, 212 (76.8%) were returned. Improvements were characterized by the number of laboratories that (i) decreased use of 3.8% sodium citrate as anticoagulant; (ii) implemented use of at least two control levels for internal quality control; and (iii) implemented reporting of reference values with results, as well as establishing their own reference range and using geometric mean as the denominator for international normalized ratio calculation. For overall satisfaction, 179 of 206 (86.9%) participant laboratories reported being satisfied or very satisfied. Improvements in coagulation laboratory practices in Thailand were observed in every step of the total testing process. However, additional improvements are still needed, such as determination and use of a local reference range. © 2016 John Wiley & Sons Ltd.

  16. Expressing analytical performance from multi-sample evaluation in laboratory EQA.

    PubMed

    Thelen, Marc H M; Jansen, Rob T P; Weykamp, Cas W; Steigstra, Herman; Meijer, Ron; Cobbaert, Christa M

    2017-08-28

    To provide its participants with an external quality assessment system (EQAS) that can be used to check trueness, the Dutch EQAS organizer, Organization for Quality Assessment of Laboratory Diagnostics (SKML), has innovated its general chemistry scheme over the last decade by introducing fresh frozen commutable samples whose values were assigned by Joint Committee for Traceability in Laboratory Medicine (JCTLM)-listed reference laboratories using reference methods where possible. Here we present some important innovations in our feedback reports that allow participants to judge whether their trueness and imprecision meet predefined analytical performance specifications. Sigma metrics are used to calculate performance indicators named 'sigma values'. Tolerance intervals are based on both Total Error allowable (TEa) according to biological variation data and state of the art (SA) in line with the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) Milan consensus. The existing SKML feedback reports that express trueness as the agreement between the regression line through the results of the last 12 months and the values obtained from reference laboratories and calculate imprecision from the residuals of the regression line are now enriched with sigma values calculated from the degree to which the combination of trueness and imprecision are within tolerance limits. The information and its conclusion to a simple two-point scoring system are also graphically represented in addition to the existing difference plot. By adding sigma metrics-based performance evaluation in relation to both TEa and SA tolerance intervals to its EQAS schemes, SKML provides its participants with a powerful and actionable check on accuracy.

  17. The life RASER and "Okkam's Razor"

    NASA Astrophysics Data System (ADS)

    Perov, Stanislav P.; Perov, Alexander S.

    2013-04-01

    A hypothesis of origin of life on the our planet must meet the conditions for well known principles of physics which are summarized in the main principle of the Science - "Okkam`s razor". It is stating: the simplest hypothesis which is accounted for the most facts is most likely to be correct. It must be furthermore attractive and extravagant. Key words: strong non-equilibrium processes, coherent-resonance structures, water plus some chemical elements (H, O, N, Ph, C ...) and resonance system (RASOR see below). The thermodynamic approach to the analysis of irreversible open non-equilibrium systems that interact with electromagnetic radiation is given. The theory of such systems has been created in USSR/Russia in the late twentieth century [2]. It applies to the living and non-living systems as in the macro and micro/nano scales. By entering into system flow of e/m radiation (i.e. absorbed power) and coming out of it, as well as included to the corresponding flow of entropy as well as included in the system of internal energy flow of reagents and out of the products, as well as to relevant incoming and outgoing flow of entropy in our scheme added integration of the external magnetic and electrical fields and gravity factor. In the scheme of power remains outgoing thermal flux and entropy, calculated by the absolute temperature of the system, and the rate of entropy generation in the system (by Ilya Prigozhin). R3+1AS3OR3 (Resonance (1/usual, 2/parametric, 3/stochastic/ 4/diversity) Amplification Stimulated (Stochastically and Synergetically ) by Outside (External) Radiation (1/electromagnetic, 2/corpuscular, 3/gravitational) [3]. Such RASOR arises very often when any comet enters an atmosphere of a planet. And forms shock layer before ice surface of the comet body. For explanation of chirality of arises life structures we use idea of gashydrats in [4] REFERENCES: 1. Chukova Yu.P. The Weber-Fechner Law.- Moscow.-2009.- 143 p 2. Perov S.P., Perov A.S. New physical approach to the analysis of cardiovascular system (CVS) and its interaction with the external factors. Scientific Education Bulletin #4 2012. Moscow. 3. Perov S., Subbaraya B.H.. Offermann D. Kruchenitsky G., Ermakov V. et al., Okkam`s Razor, Solar-Terrestrial Resonances and Global Change. Fluxes and Structures in Fluids, Int. Conf., Abstracts, Moscow.-2001.- p. 164-166 4. Ostrovskii V.E., Kadyshevich E.A. Mitosis and DNA Replication and Life Origination Hydrate Hypothesis: Common Physical and Chemical Grounds. DNA Replication - Current Advances; Ed. by Herve Seligmann. - (first publ. July, 2011. - INTECHWEB.ORG. www.intechopen.com p. 75- 114

  18. Effect of External Post-tensioning in Retrofitting of RC Beams

    NASA Astrophysics Data System (ADS)

    Manisekar, R.

    2018-05-01

    There are large number of existing concrete bridges in distressed condition in India and other countries, and they need retrofitting solutions. External post-tensioning is a prime technique for bridge retrofitting. It is being applied for retrofitting of bridges in India and other countries. Although the technique is becoming popular in retrofitting, various issues regarding performance of post-retrofitting behaviour need to be studied in detail. RC beam specimens of rectangular section were distressed by means of cracks to a certain limit, and were retrofitted by external post-tensioning. Retrofitted specimens were tested to fail to study the post-retrofitting behaviour. Retrofitting has increased the ultimate load carrying capacity by 81% with reference to the control beam, and recovered the deflection. This paper intends to report the results of the experimental investigations, and conclusions.

  19. Soil erosion assessment - Mind the gap

    NASA Astrophysics Data System (ADS)

    Kim, Jongho; Ivanov, Valeriy Y.; Fatichi, Simone

    2016-12-01

    Accurate assessment of erosion rates remains an elusive problem because soil loss is strongly nonunique with respect to the main drivers. In addressing the mechanistic causes of erosion responses, we discriminate between macroscale effects of external factors - long studied and referred to as "geomorphic external variability", and microscale effects, introduced as "geomorphic internal variability." The latter source of erosion variations represents the knowledge gap, an overlooked but vital element of geomorphic response, significantly impacting the low predictability skill of deterministic models at field-catchment scales. This is corroborated with experiments using a comprehensive physical model that dynamically updates the soil mass and particle composition. As complete knowledge of microscale conditions for arbitrary location and time is infeasible, we propose that new predictive frameworks of soil erosion should embed stochastic components in deterministic assessments of external and internal types of geomorphic variability.

  20. Childhood Bipolar Disorder: A Difficult Diagnosis

    ERIC Educational Resources Information Center

    Sutton, Kimberly Kode

    2014-01-01

    Identifying children with emotional or behavior disorders has long been problematic. In a general sense, those children who are most likely to be noticed by teachers and, therefore, referred for possible special education placement are those who exhibit externalizing behaviors, including physical aggression, noncompliance, and rule-breaking. It is…

Top