Does rational selection of training and test sets improve the outcome of QSAR modeling?
Martin, Todd M; Harten, Paul; Young, Douglas M; Muratov, Eugene N; Golbraikh, Alexander; Zhu, Hao; Tropsha, Alexander
2012-10-22
Prior to using a quantitative structure activity relationship (QSAR) model for external predictions, its predictive power should be established and validated. In the absence of a true external data set, the best way to validate the predictive ability of a model is to perform its statistical external validation. In statistical external validation, the overall data set is divided into training and test sets. Commonly, this splitting is performed using random division. Rational splitting methods can divide data sets into training and test sets in an intelligent fashion. The purpose of this study was to determine whether rational division methods lead to more predictive models compared to random division. A special data splitting procedure was used to facilitate the comparison between random and rational division methods. For each toxicity end point, the overall data set was divided into a modeling set (80% of the overall set) and an external evaluation set (20% of the overall set) using random division. The modeling set was then subdivided into a training set (80% of the modeling set) and a test set (20% of the modeling set) using rational division methods and by using random division. The Kennard-Stone, minimal test set dissimilarity, and sphere exclusion algorithms were used as the rational division methods. The hierarchical clustering, random forest, and k-nearest neighbor (kNN) methods were used to develop QSAR models based on the training sets. For kNN QSAR, multiple training and test sets were generated, and multiple QSAR models were built. The results of this study indicate that models based on rational division methods generate better statistical results for the test sets than models based on random division, but the predictive power of both types of models are comparable.
The Introduction of Standardized External Testing in Ukraine: Challenges and Successes
ERIC Educational Resources Information Center
Kovalchuk, Serhiy; Koroliuk, Svitlana
2012-01-01
Standardized external testing (SET) began to be implemented in Ukraine in 2008 as an instrument for combating corruption in higher education and ensuring fair university admission. This article examines the conditions and processes that led to the introduction of SET, overviews its implementation over three years (2008-10), analyzes SET and…
Effect of simulated forward airspeed on small-scale-model externally blown flap noise
NASA Technical Reports Server (NTRS)
Goodykoontz, J. H.; Dorsch, R. G.; Olsen, W. A.
1976-01-01
Noise tests were conducted on a small-scale model of an externally blown flap lift augmentation system. The nozzle/wing model was subjected to external flow that simulated takeoff and landing flight velocities by placing it in a 33-centimeter-diameter free jet. The results showed that external flow attenuated the noise associated with the various configurations tested. The amount of attenuation depended on flap setting. More attenuation occurred with a trailing-flap setting of 20 deg than with one of 60 deg. Noise varied with relative velocity as a function of the trailing-flap setting and the angle from the nozzle inlet.
Assessing Discriminative Performance at External Validation of Clinical Prediction Models
Nieboer, Daan; van der Ploeg, Tjeerd; Steyerberg, Ewout W.
2016-01-01
Introduction External validation studies are essential to study the generalizability of prediction models. Recently a permutation test, focusing on discrimination as quantified by the c-statistic, was proposed to judge whether a prediction model is transportable to a new setting. We aimed to evaluate this test and compare it to previously proposed procedures to judge any changes in c-statistic from development to external validation setting. Methods We compared the use of the permutation test to the use of benchmark values of the c-statistic following from a previously proposed framework to judge transportability of a prediction model. In a simulation study we developed a prediction model with logistic regression on a development set and validated them in the validation set. We concentrated on two scenarios: 1) the case-mix was more heterogeneous and predictor effects were weaker in the validation set compared to the development set, and 2) the case-mix was less heterogeneous in the validation set and predictor effects were identical in the validation and development set. Furthermore we illustrated the methods in a case study using 15 datasets of patients suffering from traumatic brain injury. Results The permutation test indicated that the validation and development set were homogenous in scenario 1 (in almost all simulated samples) and heterogeneous in scenario 2 (in 17%-39% of simulated samples). Previously proposed benchmark values of the c-statistic and the standard deviation of the linear predictors correctly pointed at the more heterogeneous case-mix in scenario 1 and the less heterogeneous case-mix in scenario 2. Conclusion The recently proposed permutation test may provide misleading results when externally validating prediction models in the presence of case-mix differences between the development and validation population. To correctly interpret the c-statistic found at external validation it is crucial to disentangle case-mix differences from incorrect regression coefficients. PMID:26881753
Assessing Discriminative Performance at External Validation of Clinical Prediction Models.
Nieboer, Daan; van der Ploeg, Tjeerd; Steyerberg, Ewout W
2016-01-01
External validation studies are essential to study the generalizability of prediction models. Recently a permutation test, focusing on discrimination as quantified by the c-statistic, was proposed to judge whether a prediction model is transportable to a new setting. We aimed to evaluate this test and compare it to previously proposed procedures to judge any changes in c-statistic from development to external validation setting. We compared the use of the permutation test to the use of benchmark values of the c-statistic following from a previously proposed framework to judge transportability of a prediction model. In a simulation study we developed a prediction model with logistic regression on a development set and validated them in the validation set. We concentrated on two scenarios: 1) the case-mix was more heterogeneous and predictor effects were weaker in the validation set compared to the development set, and 2) the case-mix was less heterogeneous in the validation set and predictor effects were identical in the validation and development set. Furthermore we illustrated the methods in a case study using 15 datasets of patients suffering from traumatic brain injury. The permutation test indicated that the validation and development set were homogenous in scenario 1 (in almost all simulated samples) and heterogeneous in scenario 2 (in 17%-39% of simulated samples). Previously proposed benchmark values of the c-statistic and the standard deviation of the linear predictors correctly pointed at the more heterogeneous case-mix in scenario 1 and the less heterogeneous case-mix in scenario 2. The recently proposed permutation test may provide misleading results when externally validating prediction models in the presence of case-mix differences between the development and validation population. To correctly interpret the c-statistic found at external validation it is crucial to disentangle case-mix differences from incorrect regression coefficients.
ERIC Educational Resources Information Center
Pantzare, Anna Lind
2015-01-01
In most large-scale assessment systems a set of rather expensive external quality controls are implemented in order to guarantee the quality of interrater reliability. This study empirically examines if teachers' ratings of national tests in mathematics can be reliable without using monitoring, training, or other methods of external quality…
Windhorst, Dafna A; Mileva-Seitz, Viara R; Rippe, Ralph C A; Tiemeier, Henning; Jaddoe, Vincent W V; Verhulst, Frank C; van IJzendoorn, Marinus H; Bakermans-Kranenburg, Marian J
2016-08-01
In a longitudinal cohort study, we investigated the interplay of harsh parenting and genetic variation across a set of functionally related dopamine genes, in association with children's externalizing behavior. This is one of the first studies to employ gene-based and gene-set approaches in tests of Gene by Environment (G × E) effects on complex behavior. This approach can offer an important alternative or complement to candidate gene and genome-wide environmental interaction (GWEI) studies in the search for genetic variation underlying individual differences in behavior. Genetic variants in 12 autosomal dopaminergic genes were available in an ethnically homogenous part of a population-based cohort. Harsh parenting was assessed with maternal (n = 1881) and paternal (n = 1710) reports at age 3. Externalizing behavior was assessed with the Child Behavior Checklist (CBCL) at age 5 (71 ± 3.7 months). We conducted gene-set analyses of the association between variation in dopaminergic genes and externalizing behavior, stratified for harsh parenting. The association was statistically significant or approached significance for children without harsh parenting experiences, but was absent in the group with harsh parenting. Similarly, significant associations between single genes and externalizing behavior were only found in the group without harsh parenting. Effect sizes in the groups with and without harsh parenting did not differ significantly. Gene-environment interaction tests were conducted for individual genetic variants, resulting in two significant interaction effects (rs1497023 and rs4922132) after correction for multiple testing. Our findings are suggestive of G × E interplay, with associations between dopamine genes and externalizing behavior present in children without harsh parenting, but not in children with harsh parenting experiences. Harsh parenting may overrule the role of genetic factors in externalizing behavior. Gene-based and gene-set analyses offer promising new alternatives to analyses focusing on single candidate polymorphisms when examining the interplay between genetic and environmental factors.
Fatemi, Mohammad Hossein; Ghorbanzad'e, Mehdi
2009-11-01
Quantitative structure-property relationship models for the prediction of the nematic transition temperature (T (N)) were developed by using multilinear regression analysis and a feedforward artificial neural network (ANN). A collection of 42 thermotropic liquid crystals was chosen as the data set. The data set was divided into three sets: for training, and an internal and external test set. Training and internal test sets were used for ANN model development, and the external test set was used for evaluation of the predictive power of the model. In order to build the models, a set of six descriptors were selected by the best multilinear regression procedure of the CODESSA program. These descriptors were: atomic charge weighted partial negatively charged surface area, relative negative charged surface area, polarity parameter/square distance, minimum most negative atomic partial charge, molecular volume, and the A component of moment of inertia, which encode geometrical and electronic characteristics of molecules. These descriptors were used as inputs to ANN. The optimized ANN model had 6:6:1 topology. The standard errors in the calculation of T (N) for the training, internal, and external test sets using the ANN model were 1.012, 4.910, and 4.070, respectively. To further evaluate the ANN model, a crossvalidation test was performed, which produced the statistic Q (2) = 0.9796 and standard deviation of 2.67 based on predicted residual sum of square. Also, the diversity test was performed to ensure the model's stability and prove its predictive capability. The obtained results reveal the suitability of ANN for the prediction of T (N) for liquid crystals using molecular structural descriptors.
No need for external orthogonality in subsystem density-functional theory.
Unsleber, Jan P; Neugebauer, Johannes; Jacob, Christoph R
2016-08-03
Recent reports on the necessity of using externally orthogonal orbitals in subsystem density-functional theory (SDFT) [Annu. Rep. Comput. Chem., 8, 2012, 53; J. Phys. Chem. A, 118, 2014, 9182] are re-investigated. We show that in the basis-set limit, supermolecular Kohn-Sham-DFT (KS-DFT) densities can exactly be represented as a sum of subsystem densities, even if the subsystem orbitals are not externally orthogonal. This is illustrated using both an analytical example and in basis-set free numerical calculations for an atomic test case. We further show that even with finite basis sets, SDFT calculations using accurate reconstructed potentials can closely approach the supermolecular KS-DFT density, and that the deviations between SDFT and KS-DFT decrease as the basis-set limit is approached. Our results demonstrate that formally, there is no need to enforce external orthogonality in SDFT, even though this might be a useful strategy when developing projection-based DFT embedding schemes.
Noise tests of a mixer nozzle-externally blown flap system
NASA Technical Reports Server (NTRS)
Goodykoontz, J. H.; Dorsch, R. G.; Groesbeck, D. E.
1973-01-01
Noise tests were conducted on a large scale model of an externally blown flap lift augmentation system, employing a mixer nozzle. The mixer nozzle consisted of seven flow passages with a total equivalent diameter of 40 centimeters. With the flaps in the 30 - 60 deg setting, the noise level below the wing was less with the mixer nozzle than when a standard circular nozzle was used. At the 10 - 20 deg flap setting, the noise levels were about the same when either nozzle was used. With retracted flaps, the noise level was higher when the mixer nozzle was used.
Proficiency Standards and Cut-Scores for Language Proficiency Tests.
ERIC Educational Resources Information Center
Moy, Raymond H.
1984-01-01
Discusses the problems associated with "grading on a curve," the approach often used for standard setting on language proficiency tests. Proposes four main steps presented in the setting of a non-arbitrary cut-score. These steps not only establish a proficiency standard checked by external criteria, but also check to see that the test covers the…
Consistency of Standard Setting in an Augmented State Testing System
ERIC Educational Resources Information Center
Lissitz, Robert W.; Wei, Hua
2008-01-01
In this article we address the issue of consistency in standard setting in the context of an augmented state testing program. Information gained from the external NRT scores is used to help make an informed decision on the determination of cut scores on the state test. The consistency of cut scores on the CRT across grades is maintained by forcing…
Augustsson, Jesper
2016-08-01
Dynamic clinical tests of hip strength applicable on patients, non-athletes and athletes alike, are lacking. The aim of this study was therefore to develop and evaluate the reliability of a dynamic muscle function test of hip external rotation strength, using a novel device. A second aim was to determine if gender differences exist in absolute and relative hip strength using the new test. Fifty-three healthy sport science students (34 women and 19 men) were tested for hip external rotation strength using a device that consisted of a strap connected in series with an elastic resistance band loop, and a measuring tape connected in parallel with the elastic resistance band. The test was carried out with the subject side lying, positioned in 45 ° of hip flexion and the knees flexed to 90 ° with the device firmly fastened proximally across the knees. The subject then exerted maximal concentric hip external rotation force against the device thereby extending the elastic resistance band. The displacement achieved by the subject was documented by the tape measure and the corresponding force production was calculated. Both right and left hip strength was measured. Fifteen of the subjects were tested on repeated occasions to evaluate test-retest reliability. No significant test-retest differences were observed. Intra-class correlation coefficients ranged 0.93-0.94 and coefficients of variation 2.76-4.60%. In absolute values, men were significantly stronger in hip external rotation than women (right side 13.2 vs 11.0 kg, p = 0.001, left side 13.2 vs 11.5 kg, p = 0.002). There were no significant differences in hip external rotation strength normalized for body weight (BW) between men and women (right side 0.17 kg/BW vs 0.17 kg/BW, p = 0.675, left side 0.17 kg/BW vs 0.18 kg/BW, p = 0.156). The new muscle function test showed high reliability and thus could be useful for measuring dynamic hip external rotation strength in patients, non-athletes and athletes. The test is practical and easy to perform in any setting and could therefore provide additional information to the common clinical hip examination, in the rehabilitation or research setting, as well as when conducting on-the-field testing in sports. 3.
Zhang, Hui; Ren, Ji-Xia; Kang, Yan-Li; Bo, Peng; Liang, Jun-Yu; Ding, Lan; Kong, Wei-Bao; Zhang, Ji
2017-08-01
Toxicological testing associated with developmental toxicity endpoints are very expensive, time consuming and labor intensive. Thus, developing alternative approaches for developmental toxicity testing is an important and urgent task in the drug development filed. In this investigation, the naïve Bayes classifier was applied to develop a novel prediction model for developmental toxicity. The established prediction model was evaluated by the internal 5-fold cross validation and external test set. The overall prediction results for the internal 5-fold cross validation of the training set and external test set were 96.6% and 82.8%, respectively. In addition, four simple descriptors and some representative substructures of developmental toxicants were identified. Thus, we hope the established in silico prediction model could be used as alternative method for toxicological assessment. And these obtained molecular information could afford a deeper understanding on the developmental toxicants, and provide guidance for medicinal chemists working in drug discovery and lead optimization. Copyright © 2017 Elsevier Inc. All rights reserved.
Does Rational Selection of Training and Test Sets Improve the Outcome of QSAR Modeling?
Prior to using a quantitative structure activity relationship (QSAR) model for external predictions, its predictive power should be established and validated. In the absence of a true external dataset, the best way to validate the predictive ability of a model is to perform its s...
Wollin, Martin; Purdam, Craig; Drew, Michael K
2016-01-01
To investigate inter and intra-tester reliability of an externally fixed dynamometry unilateral hamstring strength test, in the elite sports setting. Reliability study. Sixteen, injury-free, elite male youth football players (age=16.81±0.54 years, height=180.22±5.29cm, weight 73.88±6.54kg, BMI=22.57±1.42) gave written informed consent. Unilateral maximum isometric peak hamstring force was evaluated by externally fixed dynamometry for inter-tester, intra-day and intra-tester, inter-week reliability. The test position was standardised to correlate with the terminal swing phase of the gait running cycle. Inter and intra-tester values demonstrated good to high levels of reliability. The intra-class coefficient (ICC) for inter-tester, intra-day reliability was 0.87 (95% CI=0.75-0.93) with standard error of measure percentage (SEM%) 4.7 and minimal detectable change percentage (MDC%) 12.9. Intra-tester, inter-week reliability results were ICC 0.86 (95% CI, 0.74-0.93), SEM% 5.0 and MDC% 14.0. This study demonstrates good to high inter and intra-tester reliability of isometric externally fixed dynamometry unilateral hamstring strength testing in the regular elite sport setting involving elite male youth football players. The intra-class coefficient in association with the low standard error of measure and minimal detectable change percentages suggest that this procedure is appropriate for clinical and academic use as well as monitoring hamstring strength in the elite sport setting. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.
Novel naïve Bayes classification models for predicting the chemical Ames mutagenicity.
Zhang, Hui; Kang, Yan-Li; Zhu, Yuan-Yuan; Zhao, Kai-Xia; Liang, Jun-Yu; Ding, Lan; Zhang, Teng-Guo; Zhang, Ji
2017-06-01
Prediction of drug candidates for mutagenicity is a regulatory requirement since mutagenic compounds could pose a toxic risk to humans. The aim of this investigation was to develop a novel prediction model of mutagenicity by using a naïve Bayes classifier. The established model was validated by the internal 5-fold cross validation and external test sets. For comparison, the recursive partitioning classifier prediction model was also established and other various reported prediction models of mutagenicity were collected. Among these methods, the prediction performance of naïve Bayes classifier established here displayed very well and stable, which yielded average overall prediction accuracies for the internal 5-fold cross validation of the training set and external test set I set were 89.1±0.4% and 77.3±1.5%, respectively. The concordance of the external test set II with 446 marketed drugs was 90.9±0.3%. In addition, four simple molecular descriptors (e.g., Apol, No. of H donors, Num-Rings and Wiener) related to mutagenicity and five representative substructures of mutagens (e.g., aromatic nitro, hydroxyl amine, nitroso, aromatic amine and N-methyl-N-methylenemethanaminum) produced by ECFP_14 fingerprints were identified. We hope the established naïve Bayes prediction model can be applied to risk assessment processes; and the obtained important information of mutagenic chemicals can guide the design of chemical libraries for hit and lead optimization. Copyright © 2017 Elsevier B.V. All rights reserved.
Proposed methods for testing and selecting the ERCC external RNA controls
2005-01-01
The External RNA Control Consortium (ERCC) is an ad-hoc group with approximately 70 members from private, public, and academic organizations. The group is developing a set of external RNA control transcripts that can be used to assess technical performance in gene expression assays. The ERCC is now initiating the Testing Phase of the project, during which candidate external RNA controls will be evaluated in both microarray and QRT-PCR gene expression platforms. This document describes the proposed experiments and informatics process that will be followed to test and qualify individual controls. The ERCC is distributing this description of the proposed testing process in an effort to gain consensus and to encourage feedback from the scientific community. On October 4–5, 2005, the ERCC met to further review the document, clarify ambiguities, and plan next steps. A summary of this meeting and changes to the test plan are provided as an appendix to this manuscript. PMID:16266432
Volumetric flow rate in simulations of microfluidic devices+
NASA Astrophysics Data System (ADS)
Kovalčíková, KristÍna; Slavík, Martin; Bachratá, Katarína; Bachratý, Hynek; Bohiniková, Alžbeta
2018-06-01
In this work, we examine the volumetric flow rate of microfluidic devices. The volumetric flow rate is a parameter which is necessary to correctly set up a simulation of a real device and to check the conformity of a simulation and a laboratory experiments [1]. Instead of defining the volumetric rate at the beginning as a simulation parameter, a parameter of external force is set. The proposed hypothesis is that for a fixed set of other parameters (topology, viscosity of the liquid, …) the volumetric flow rate is linearly dependent on external force in typical ranges of fluid velocity used in our simulations. To confirm this linearity hypothesis and to find numerical limits of this approach, we test several values of the external force parameter. The tests are designed for three different topologies of simulation box and for various haematocrits. The topologies of the microfluidic devices are inspired by existing laboratory experiments [3 - 6]. The linear relationship between the external force and the volumetric flow rate is verified in orders of magnitudes similar to the values obtained from laboratory experiments. Supported by the Slovak Research and Development Agency under the contract No. APVV-15-0751 and by the Ministry of Education, Science, Research and Sport of the Slovak Republic under the contract No. VEGA 1/0643/17.
Phinney, Karen W; Sempos, Christopher T; Tai, Susan S-C; Camara, Johanna E; Wise, Stephen A; Eckfeldt, John H; Hoofnagle, Andrew N; Carter, Graham D; Jones, Julia; Myers, Gary L; Durazo-Arvizu, Ramon; Miller, W Greg; Bachmann, Lorin M; Young, Ian S; Pettit, Juanita; Caldwell, Grahame; Liu, Andrew; Brooks, Stephen P J; Sarafin, Kurtis; Thamm, Michael; Mensink, Gert B M; Busch, Markus; Rabenberg, Martina; Cashman, Kevin D; Kiely, Mairead; Galvin, Karen; Zhang, Joy Y; Kinsella, Michael; Oh, Kyungwon; Lee, Sun-Wha; Jung, Chae L; Cox, Lorna; Goldberg, Gail; Guberg, Kate; Meadows, Sarah; Prentice, Ann; Tian, Lu; Brannon, Patsy M; Lucas, Robyn M; Crump, Peter M; Cavalier, Etienne; Merkel, Joyce; Betz, Joseph M
2017-09-01
The Vitamin D Standardization Program (VDSP) coordinated a study in 2012 to assess the commutability of reference materials and proficiency testing/external quality assurance materials for total 25-hydroxyvitamin D [25(OH)D] in human serum, the primary indicator of vitamin D status. A set of 50 single-donor serum samples as well as 17 reference and proficiency testing/external quality assessment materials were analyzed by participating laboratories that used either immunoassay or LC-MS methods for total 25(OH)D. The commutability test materials included National Institute of Standards and Technology Standard Reference Material 972a Vitamin D Metabolites in Human Serum as well as materials from the College of American Pathologists and the Vitamin D External Quality Assessment Scheme. Study protocols and data analysis procedures were in accordance with Clinical and Laboratory Standards Institute guidelines. The majority of the test materials were found to be commutable with the methods used in this commutability study. These results provide guidance for laboratories needing to choose appropriate reference materials and select proficiency or external quality assessment programs and will serve as a foundation for additional VDSP studies.
Pizzo, Fabiola; Lombardo, Anna; Manganaro, Alberto; Benfenati, Emilio
2016-01-01
The prompt identification of chemical molecules with potential effects on liver may help in drug discovery and in raising the levels of protection for human health. Besides in vitro approaches, computational methods in toxicology are drawing attention. We built a structure-activity relationship (SAR) model for evaluating hepatotoxicity. After compiling a data set of 950 compounds using data from the literature, we randomly split it into training (80%) and test sets (20%). We also compiled an external validation set (101 compounds) for evaluating the performance of the model. To extract structural alerts (SAs) related to hepatotoxicity and non-hepatotoxicity we used SARpy, a statistical application that automatically identifies and extracts chemical fragments related to a specific activity. We also applied the chemical grouping approach for manually identifying other SAs. We calculated accuracy, specificity, sensitivity and Matthews correlation coefficient (MCC) on the training, test and external validation sets. Considering the complexity of the endpoint, the model performed well. In the training, test and external validation sets the accuracy was respectively 81, 63, and 68%, specificity 89, 33, and 33%, sensitivity 93, 88, and 80% and MCC 0.63, 0.27, and 0.13. Since it is preferable to overestimate hepatotoxicity rather than not to recognize unsafe compounds, the model's architecture followed a conservative approach. As it was built using human data, it might be applied without any need for extrapolation from other species. This model will be freely available in the VEGA platform. PMID:27920722
External RNA Controls Consortium Beta Version Update.
Lee, Hangnoh; Pine, P Scott; McDaniel, Jennifer; Salit, Marc; Oliver, Brian
2016-01-01
Spike-in RNAs are valuable controls for a variety of gene expression measurements. The External RNA Controls Consortium developed test sets that were used in a number of published reports. Here we provide an authoritative table that summarizes, updates, and corrects errors in the test version that ultimately resulted in the certified Standard Reference Material 2374. We have noted existence of anti-sense RNA controls in the material, corrected sub-pool memberships, and commented on control RNAs that displayed inconsistent behavior.
Rácz, A; Bajusz, D; Héberger, K
2015-01-01
Recent implementations of QSAR modelling software provide the user with numerous models and a wealth of information. In this work, we provide some guidance on how one should interpret the results of QSAR modelling, compare and assess the resulting models, and select the best and most consistent ones. Two QSAR datasets are applied as case studies for the comparison of model performance parameters and model selection methods. We demonstrate the capabilities of sum of ranking differences (SRD) in model selection and ranking, and identify the best performance indicators and models. While the exchange of the original training and (external) test sets does not affect the ranking of performance parameters, it provides improved models in certain cases (despite the lower number of molecules in the training set). Performance parameters for external validation are substantially separated from the other merits in SRD analyses, highlighting their value in data fusion.
Schriver, Michael; Cubaka, Vincent Kalumire; Vedsted, Peter; Besigye, Innocent; Kallestrup, Per
2018-01-01
External supervision of primary health care facilities to monitor and improve services is common in low-income countries. Currently there are no tools to measure the quality of support in external supervision in these countries. To develop a provider-reported instrument to assess the support delivered through external supervision in Rwanda and other countries. "External supervision: Provider Evaluation of Supervisor Support" (ExPRESS) was developed in 18 steps, primarily in Rwanda. Content validity was optimised using systematic search for related instruments, interviews, translations, and relevance assessments by international supervision experts as well as local experts in Nigeria, Kenya, Uganda and Rwanda. Construct validity and reliability were examined in two separate field tests, the first using exploratory factor analysis and a test-retest design, the second for confirmatory factor analysis. We included 16 items in section A ('The most recent experience with an external supervisor'), and 13 items in section B ('The overall experience with external supervisors'). Item-content validity index was acceptable. In field test I, test-retest had acceptable kappa values and exploratory factor analysis suggested relevant factors in sections A and B used for model hypotheses. In field test II, models were tested by confirmatory factor analysis fitting a 4-factor model for section A, and a 3-factor model for section B. ExPRESS is a promising tool for evaluation of the quality of support of primary health care providers in external supervision of primary health care facilities in resource-constrained settings. ExPRESS may be used as specific feedback to external supervisors to help identify and address gaps in the supervision they provide. Further studies should determine optimal interpretation of scores and the number of respondents needed per supervisor to obtain precise results, as well as test the functionality of section B.
2007-12-15
KENNEDY SPACE CENTER, FLA. -- On Launch Pad 39A at NASA's Kennedy Space Center, a technician sets up wiring for the tanking test on space shuttle Atlantis' external tank set for Dec. 18. The test wiring has been spliced into an electrical harness in the aft main engine compartment connected with the engine cut-off, or ECO, sensor system. The attached wiring leads to the interior of the mobile launcher platform where the time domain reflectometry, or TDR, test equipment is located. Photo credit: NASA/Kim Shiflett
2007-12-15
KENNEDY SPACE CENTER, FLA. -- On Launch Pad 39A at NASA's Kennedy Space Center, a wiring board has been set up for the tanking test on space shuttle Atlantis' external tank set for Dec. 18. The test wiring has been spliced into an electrical harness in the aft main engine compartment connected with the engine cut-off, or ECO, sensor system. The attached wiring leads to the interior of the mobile launcher platform where the time domain reflectometry, or TDR, test equipment is located. Photo credit: NASA/Kim Shiflett
Acoustic characteristics of externally blown flap systems with mixer nozzles
NASA Technical Reports Server (NTRS)
Goodykoontz, J. H.; Dorsch, R. G.; Wagner, J. M.
1974-01-01
Noise tests were conducted on a large scale, cold flow model of an engine-under-the-wing externally blown flap lift augmentation system employing a mixer nozzle. The mixer nozzle was used to reduce the flap impingement velocity and, consequently, try to attenuate the additional noise caused by the interaction between the jet exhaust and the wing flap. Results from the mixer nozzle tests are summarized and compared with the results for a conical nozzle. The comparison showed that with the mixer nozzle, less noise was generated when the trailing flap was in a typical landing setting (e.g., 60 deg). However, for a takeoff flap setting (20 deg), there was little or no difference in the acoustic characteristics when either the mixer or conical nozzle was used.
Ebrahimi-Najafabadi, Heshmatollah; Leardi, Riccardo; Oliveri, Paolo; Casolino, Maria Chiara; Jalali-Heravi, Mehdi; Lanteri, Silvia
2012-09-15
The current study presents an application of near infrared spectroscopy for identification and quantification of the fraudulent addition of barley in roasted and ground coffee samples. Nine different types of coffee including pure Arabica, Robusta and mixtures of them at different roasting degrees were blended with four types of barley. The blending degrees were between 2 and 20 wt% of barley. D-optimal design was applied to select 100 and 30 experiments to be used as calibration and test set, respectively. Partial least squares regression (PLS) was employed to build the models aimed at predicting the amounts of barley in coffee samples. In order to obtain simplified models, taking into account only informative regions of the spectral profiles, a genetic algorithm (GA) was applied. A completely independent external set was also used to test the model performances. The models showed excellent predictive ability with root mean square errors (RMSE) for the test and external set equal to 1.4% w/w and 0.8% w/w, respectively. Copyright © 2012 Elsevier B.V. All rights reserved.
Strauss, Eric J; Ishak, Charbel; Inzerillo, Christopher; Walsh, Michael; Yildirim, Gokce; Walker, Peter; Jazrawi, Laith; Rosen, Jeffrey
2007-08-01
To determine whether positioning of the tibia affects the degree of tibial external rotation seen during a dial test in the posterior cruciate ligament (PCL)-posterolateral corner (PLC)-deficient knee. Laboratory investigation. Biomechanics laboratory. An anterior force applied to the tibia in the combined PCL-PLC-deficient knee will yield increased tibial external rotation during a dial test. The degree of tibial external rotation was measured with 5 Nm of external rotation torque applied to the tibia at both 30 degrees and 90 degrees of knee flexion. Before the torque was applied, an anterior force, a posterior force, or neutral (normal, reduced control) force was applied to the tibia. External rotation measurements were repeated after sequential sectioning of the PCL, the posterolateral structures and the fibular collateral ligament (FCL). Baseline testing of the intact specimens demonstrated a mean external rotation of 18.6 degrees with the knee flexed to 30 degrees (range 16.1-21.0 degrees ), and a mean external rotation of 17.3 degrees with the knee flexed to 90 degrees (range 13.8-20.0 degrees ). Sequential sectioning of the PCL, popliteus and popliteofibular ligament, and the FCL led to a significant increase in tibial external rotation compared with the intact knee for all testing scenarios. After sectioning of the popliteus and popliteofibular ligament, the application of an anterior force during testing led to a mean tibial external rotation that was 5 degrees greater than during testing in the neutral position and 7.5 degrees greater than during testing with a posterior force. In the PCL, popliteus/popliteofibular ligament and FCL-deficient knee, external rotation was 9 degrees and 12 degrees greater with the application of an anterior force during testing compared with neutral positioning and the application of a posterior force, respectively. An anterior force applied to the tibia during the dial test in a combined PCL-PLC-injured knee increased the overall amount of observed tibial external rotation during the dial test. The anterior force reduced the posterior tibial subluxation associated with PCL injury, which is analogous to what is observed when the dial test is performed with the patient in the prone position. Reducing the tibia with either an anterior force when the patient is supine or performing the dial test with the patient in the prone position increases the ability of an examiner to detect a concomitant PLC injury in the setting of a PCL-deficient knee.
Identifying and Evaluating External Validity Evidence for Passing Scores
ERIC Educational Resources Information Center
Davis-Becker, Susan L.; Buckendahl, Chad W.
2013-01-01
A critical component of the standard setting process is collecting evidence to evaluate the recommended cut scores and their use for making decisions and classifying students based on test performance. Kane (1994, 2001) proposed a framework by which practitioners can identify and evaluate evidence of the results of the standard setting from (1)…
Using EIKEN, TOEFL, and TOEIC to Award EFL Course Credits in Japanese Universities
ERIC Educational Resources Information Center
In'nami, Yo; Koizumi, Rie
2017-01-01
Despite the wide use of language tests as a basis for awarding English language course credits at Japanese universities, little has been published about how universities set policies on awarding credits according to external test scores. To narrow this gap, the characteristics of such policies were investigated in relation to the EIKEN Test in…
Alcohol-related Genes Show an Enrichment of Associations with a Persistent Externalizing Factor
Ashenhurst, James R.; Harden, K. Paige; Corbin, William R.; Fromme, Kim
2016-01-01
Research using twins has found that much of the variability in externalizing phenotypes – including alcohol and drug use, impulsive personality traits, risky sex and property crime – is explained by genetic factors. Nevertheless, identification of specific genes and variants associated with these traits has proven to be difficult, likely because individual differences in externalizing are explained by many genes of small individual effect. Moreover, twin research indicates that heritable variance in externalizing behaviors is mostly shared across the externalizing spectrum rather than specific to any behavior. We use a longitudinal, “deep phenotyping” approach to model a general externalizing factor reflecting persistent engagement in a variety of socially problematic behaviors measured at eleven assessment occasions spanning early adulthood (ages 18 to 28). In an ancestrally homogenous sample of non-Hispanic Whites (N = 337), we then tested for enrichment of associations between the persistent externalizing factor and a set of 3,281 polymorphisms within 104 genes that were previously identified as associated with alcohol-use behaviors. Next we tested for enrichment among domain-specific factors (e.g., property crime) composed of residual variance not accounted for by the common factor. Significance was determined relative to bootstrapped empirical thresholds derived from permutations of phenotypic data. Results indicated significant enrichment of genetic associations for persistent externalizing, but not for domain-specific factors. Consistent with twin research findings, these results suggest that genetic variants are broadly associated with externalizing behaviors rather than unique to specific behaviors. General Scientific Summary This study shows that variation in 104 genes is associated with socially problematic “externalizing” behavior, including substance misuse, property crime, risky sex, and aspects of impulsive personality. Importantly, this association was with the common variation across these behaviors rather than with the variation unique to any given behavior. The manuscript demonstrates a potentially advantageous technique for relating sets of hypothesized genes to complex traits or behaviors. PMID:27505405
Wouters, Edwin; Rau, Asta; Engelbrecht, Michelle; Uebel, Kerry; Siegel, Jacob; Masquillier, Caroline; Kigozi, Gladys; Sommerland, Nina; Yassi, Annalee
2016-05-15
The dual burden of tuberculosis and human immunodeficiency virus (HIV) is severely impacting the South African healthcare workforce. However, the use of on-site occupational health services is hampered by stigma among the healthcare workforce. The success of stigma-reduction interventions is difficult to evaluate because of a dearth of appropriate scientific tools to measure stigma in this specific professional setting. The current pilot study aimed to develop and test a range of scales measuring different aspects of stigma-internal and external stigma toward tuberculosis as well as HIV-in a South African healthcare setting. The study employed data of a sample of 200 staff members of a large hospital in Bloemfontein, South Africa. Confirmatory factor analysis produced 7 scales, displaying internal construct validity: (1) colleagues' external HIV stigma, (2) colleagues' actions against external HIV stigma, (3) respondent's external HIV stigma, (4) respondent's internal HIV stigma, (5) colleagues' external tuberculosis stigma, (6) respondent's external tuberculosis stigma, and (7) respondent's internal tuberculosis stigma. Subsequent analyses (reliability analysis, structural equation modeling) demonstrated that the scales displayed good psychometric properties in terms of reliability and external construct validity. The study outcomes support the use of the developed scales as a valid and reliable means to measure levels of tuberculosis- and HIV-related stigma among the healthcare workforce in a resource-limited context. Future studies should build on these findings to fine-tune the instruments and apply them to larger study populations across a range of different resource-limited healthcare settings with high HIV and tuberculosis prevalence. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.
Wouters, Edwin; Rau, Asta; Engelbrecht, Michelle; Uebel, Kerry; Siegel, Jacob; Masquillier, Caroline; Kigozi, Gladys; Sommerland, Nina; Yassi, Annalee
2016-01-01
Background The dual burden of tuberculosis and human immunodeficiency virus (HIV) is severely impacting the South African healthcare workforce. However, the use of on-site occupational health services is hampered by stigma among the healthcare workforce. The success of stigma-reduction interventions is difficult to evaluate because of a dearth of appropriate scientific tools to measure stigma in this specific professional setting. Methods The current pilot study aimed to develop and test a range of scales measuring different aspects of stigma—internal and external stigma toward tuberculosis as well as HIV—in a South African healthcare setting. The study employed data of a sample of 200 staff members of a large hospital in Bloemfontein, South Africa. Results Confirmatory factor analysis produced 7 scales, displaying internal construct validity: (1) colleagues’ external HIV stigma, (2) colleagues’ actions against external HIV stigma, (3) respondent’s external HIV stigma, (4) respondent’s internal HIV stigma, (5) colleagues’ external tuberculosis stigma, (6) respondent’s external tuberculosis stigma, and (7) respondent’s internal tuberculosis stigma. Subsequent analyses (reliability analysis, structural equation modeling) demonstrated that the scales displayed good psychometric properties in terms of reliability and external construct validity. Conclusions The study outcomes support the use of the developed scales as a valid and reliable means to measure levels of tuberculosis- and HIV-related stigma among the healthcare workforce in a resource-limited context. Future studies should build on these findings to fine-tune the instruments and apply them to larger study populations across a range of different resource-limited healthcare settings with high HIV and tuberculosis prevalence. PMID:27118854
In silico prediction of ROCK II inhibitors by different classification approaches.
Cai, Chuipu; Wu, Qihui; Luo, Yunxia; Ma, Huili; Shen, Jiangang; Zhang, Yongbin; Yang, Lei; Chen, Yunbo; Wen, Zehuai; Wang, Qi
2017-11-01
ROCK II is an important pharmacological target linked to central nervous system disorders such as Alzheimer's disease. The purpose of this research is to generate ROCK II inhibitor prediction models by machine learning approaches. Firstly, four sets of descriptors were calculated with MOE 2010 and PaDEL-Descriptor, and optimized by F-score and linear forward selection methods. In addition, four classification algorithms were used to initially build 16 classifiers with k-nearest neighbors [Formula: see text], naïve Bayes, Random forest, and support vector machine. Furthermore, three sets of structural fingerprint descriptors were introduced to enhance the predictive capacity of classifiers, which were assessed with fivefold cross-validation, test set validation and external test set validation. The best two models, MFK + MACCS and MLR + SubFP, have both MCC values of 0.925 for external test set. After that, a privileged substructure analysis was performed to reveal common chemical features of ROCK II inhibitors. Finally, binding modes were analyzed to identify relationships between molecular descriptors and activity, while main interactions were revealed by comparing the docking interaction of the most potent and the weakest ROCK II inhibitors. To the best of our knowledge, this is the first report on ROCK II inhibitors utilizing machine learning approaches that provides a new method for discovering novel ROCK II inhibitors.
Melfsen, Andreas; Hartung, Eberhard; Haeussermann, Angelika
2013-02-01
The robustness of in-line raw milk analysis with near-infrared spectroscopy (NIRS) was tested with respect to the prediction of the raw milk contents fat, protein and lactose. Near-infrared (NIR) spectra of raw milk (n = 3119) were acquired on three different farms during the milking process of 354 milkings over a period of six months. Calibration models were calculated for: a random data set of each farm (fully random internal calibration); first two thirds of the visits per farm (internal calibration); whole datasets of two of the three farms (external calibration), and combinations of external and internal datasets. Validation was done either on the remaining data set per farm (internal validation) or on data of the remaining farms (external validation). Excellent calibration results were obtained when fully randomised internal calibration sets were used for milk analysis. In this case, RPD values of around ten, five and three for the prediction of fat, protein and lactose content, respectively, were achieved. Farm internal calibrations achieved much poorer prediction results especially for the prediction of protein and lactose with RPD values of around two and one respectively. The prediction accuracy improved when validation was done on spectra of an external farm, mainly due to the higher sample variation in external calibration sets in terms of feeding diets and individual cow effects. The results showed that further improvements were achieved when additional farm information was added to the calibration set. One of the main requirements towards a robust calibration model is the ability to predict milk constituents in unknown future milk samples. The robustness and quality of prediction increases with increasing variation of, e.g., feeding and cow individual milk composition in the calibration model.
Bittante, G; Ferragina, A; Cipolat-Gotet, C; Cecchinato, A
2014-10-01
Cheese yield is an important technological trait in the dairy industry. The aim of this study was to infer the genetic parameters of some cheese yield-related traits predicted using Fourier-transform infrared (FTIR) spectral analysis and compare the results with those obtained using an individual model cheese-producing procedure. A total of 1,264 model cheeses were produced using 1,500-mL milk samples collected from individual Brown Swiss cows, and individual measurements were taken for 10 traits: 3 cheese yield traits (fresh curd, curd total solids, and curd water as a percent of the weight of the processed milk), 4 milk nutrient recovery traits (fat, protein, total solids, and energy of the curd as a percent of the same nutrient in the processed milk), and 3 daily cheese production traits per cow (fresh curd, total solids, and water weight of the curd). Each unprocessed milk sample was analyzed using a MilkoScan FT6000 (Foss, Hillerød, Denmark) over the spectral range, from 5,000 to 900 wavenumber × cm(-1). The FTIR spectrum-based prediction models for the previously mentioned traits were developed using modified partial least-square regression. Cross-validation of the whole data set yielded coefficients of determination between the predicted and measured values in cross-validation of 0.65 to 0.95 for all traits, except for the recovery of fat (0.41). A 3-fold external validation was also used, in which the available data were partitioned into 2 subsets: a training set (one-third of the herds) and a testing set (two-thirds). The training set was used to develop calibration equations, whereas the testing subsets were used for external validation of the calibration equations and to estimate the heritabilities and genetic correlations of the measured and FTIR-predicted phenotypes. The coefficients of determination between the predicted and measured values in cross-validation results obtained from the training sets were very similar to those obtained from the whole data set, but the coefficient of determination of validation values for the external validation sets were much lower for all traits (0.30 to 0.73), and particularly for fat recovery (0.05 to 0.18), for the training sets compared with the full data set. For each testing subset, the (co)variance components for the measured and FTIR-predicted phenotypes were estimated using bivariate Bayesian analyses and linear models. The intraherd heritabilities for the predicted traits obtained from our internal cross-validation using the whole data set ranged from 0.085 for daily yield of curd solids to 0.576 for protein recovery, and were similar to those obtained from the measured traits (0.079 to 0.586, respectively). The heritabilities estimated from the testing data set used for external validation were more variable but similar (on average) to the corresponding values obtained from the whole data set. Moreover, the genetic correlations between the predicted and measured traits were high in general (0.791 to 0.996), and they were always higher than the corresponding phenotypic correlations (0.383 to 0.995), especially for the external validation subset. In conclusion, we herein report that application of the cross-validation technique to the whole data set tended to overestimate the predictive ability of FTIR spectra, give more precise phenotypic predictions than the calibrations obtained using smaller data sets, and yield genetic correlations similar to those obtained from the measured traits. Collectively, our findings indicate that FTIR predictions have the potential to be used as indicator traits for the rapid and inexpensive selection of dairy populations for improvement of cheese yield, milk nutrient recovery in curd, and daily cheese production per cow. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Wiker, Gordon A. (Inventor); Wells, Jr., George H. (Inventor)
1989-01-01
A timing control system is disclosed which is particularly useful in connection with simulated mortar shells. Special circuitry is provided to assure that the shell does not overshoot, but rather detonates early in case of an improper condition; this ensures that ground personnel will not be harmed by a delayed detonation. The system responds to an externally applied frequency control code which is configured to avoid any confusion between different control modes. A premature detonation routine is entered in case an improper time-setting signal is entered, or if the shell is launched before completion of the time-setting sequence. Special provisions are also made for very early launch situations and improper detonator connections. An alternate abort mode is provided to discharge the internal power supply without a detonation in a manner that can be externally monitored, thereby providing a mechanism for non-destructive testing. The abort mode also accelerates the timing function for rapid testing.
NASA Technical Reports Server (NTRS)
Wiker, Gordon A. (Inventor); Wells, George H., Jr. (Inventor)
1987-01-01
A timing control system is disclosed which is particularly useful in connection with simulated mortar shells. Special circuitry is provided to assure that the shell does not over shoot, but rather detonates early in case of an improper condition; this ensures that ground personnel will not be harmed by a delayed detonation. The system responds to an externally applied frequency control code which is configured to avoid any confusion between different control modes. A premature detonation routine is entered in case an improper time-setting signal is entered, or if the shell is launched before completion of the time-setting sequence. Special provisions are also made for very early launch situations and improper detonator connections. An alternate abort mode is provided to discharge the internal power supply without a detonation in a manner that can be externally monitored, thereby providing a mechanism for non-destructive testing. The abort mode also accelerates the timing function for rapid testing.
Prediction of pelvic organ prolapse using an artificial neural network.
Robinson, Christopher J; Swift, Steven; Johnson, Donna D; Almeida, Jonas S
2008-08-01
The objective of this investigation was to test the ability of a feedforward artificial neural network (ANN) to differentiate patients who have pelvic organ prolapse (POP) from those who retain good pelvic organ support. Following institutional review board approval, patients with POP (n = 87) and controls with good pelvic organ support (n = 368) were identified from the urogynecology research database. Historical and clinical information was extracted from the database. Data analysis included the training of a feedforward ANN, variable selection, and external validation of the model with an independent data set. Twenty variables were used. The median-performing ANN model used a median of 3 (quartile 1:3 to quartile 3:5) variables and achieved an area under the receiver operator curve of 0.90 (external, independent validation set). Ninety percent sensitivity and 83% specificity were obtained in the external validation by ANN classification. Feedforward ANN modeling is applicable to the identification and prediction of POP.
Iterative random vs. Kennard-Stone sampling for IR spectrum-based classification task using PLS2-DA
NASA Astrophysics Data System (ADS)
Lee, Loong Chuen; Liong, Choong-Yeun; Jemain, Abdul Aziz
2018-04-01
External testing (ET) is preferred over auto-prediction (AP) or k-fold-cross-validation in estimating more realistic predictive ability of a statistical model. With IR spectra, Kennard-stone (KS) sampling algorithm is often used to split the data into training and test sets, i.e. respectively for model construction and for model testing. On the other hand, iterative random sampling (IRS) has not been the favored choice though it is theoretically more likely to produce reliable estimation. The aim of this preliminary work is to compare performances of KS and IRS in sampling a representative training set from an attenuated total reflectance - Fourier transform infrared spectral dataset (of four varieties of blue gel pen inks) for PLS2-DA modeling. The `best' performance achievable from the dataset is estimated with AP on the full dataset (APF, error). Both IRS (n = 200) and KS were used to split the dataset in the ratio of 7:3. The classic decision rule (i.e. maximum value-based) is employed for new sample prediction via partial least squares - discriminant analysis (PLS2-DA). Error rate of each model was estimated repeatedly via: (a) AP on full data (APF, error); (b) AP on training set (APS, error); and (c) ET on the respective test set (ETS, error). A good PLS2-DA model is expected to produce APS, error and EVS, error that is similar to the APF, error. Bearing that in mind, the similarities between (a) APS, error vs. APF, error; (b) ETS, error vs. APF, error and; (c) APS, error vs. ETS, error were evaluated using correlation tests (i.e. Pearson and Spearman's rank test), using series of PLS2-DA models computed from KS-set and IRS-set, respectively. Overall, models constructed from IRS-set exhibits more similarities between the internal and external error rates than the respective KS-set, i.e. less risk of overfitting. In conclusion, IRS is more reliable than KS in sampling representative training set.
Aerts, Frank; Carrier, Kathy; Alwood, Becky
2016-01-01
Background: The assessment of clinical manifestation of muscle fatigue is an effective procedure in establishing therapeutic exercise dose. Few studies have evaluated physical therapist reliability in establishing muscle fatigue through detection of changes in quality of movement patterns in a live setting. Objective: The purpose of this study is to evaluate the inter-rater reliability of physical therapists’ ability to detect altered movement patterns due to muscle fatigue. Design: A reliability study in a live setting with multiple raters. Participants: Forty-four healthy individuals (ages 19-35) were evaluated by six physical therapists in a live setting. Methods: Participants were evaluated by physical therapists for altered movement patterns during resisted shoulder rotation. Each participant completed a total of four tests: right shoulder internal rotation, right shoulder external rotation, left shoulder internal rotation and left shoulder external rotation. Results: For all tests combined, the inter-rater reliability for a single rater scoring ICC (2,1) was .65 (95%, .60, .71) This corresponds to moderate inter-rater reliability between physical therapists. Limitations: The results of this study apply only to healthy participants and therefore cannot be generalized to a symptomatic population. Conclusion: Moderate inter-rater reliability was found between physical therapists in establishing muscle fatigue through the observation of sustained altered movement patterns during dynamic resistive shoulder internal and external rotation. PMID:27347241
Lee, Jin; Huang, Yueng-hsiang; Robertson, Michelle M; Murphy, Lauren A; Garabet, Angela; Chang, Wen-Ruey
2014-02-01
The goal of this study was to examine the external validity of a 12-item generic safety climate scale for lone workers in order to evaluate the appropriateness of generalized use of the scale in the measurement of safety climate across various lone work settings. External validity evidence was established by investigating the measurement equivalence (ME) across different industries and companies. Confirmatory factor analysis (CFA)-based and item response theory (IRT)-based perspectives were adopted to examine the ME of the generic safety climate scale for lone workers across 11 companies from the trucking, electrical utility, and cable television industries. Fairly strong evidence of ME was observed for both organization- and group-level generic safety climate sub-scales. Although significant invariance was observed in the item intercepts across the different lone work settings, absolute model fit indices remained satisfactory in the most robust step of CFA-based ME testing. IRT-based ME testing identified only one differentially functioning item from the organization-level generic safety climate sub-scale, but its impact was minimal and strong ME was supported. The generic safety climate scale for lone workers reported good external validity and supported the presence of a common feature of safety climate among lone workers. The scale can be used as an effective safety evaluation tool in various lone work situations. Copyright © 2013 Elsevier Ltd. All rights reserved.
LeBa, Thu-Ba; Gugala, Zbigniew; Morris, Randal P; Panchbhavi, Vinod K
2015-06-01
The purpose of this prospective study was to determine whether gravity versus manual external rotation stress testing effectively detects widening of the medial clear space in isolated ankle fractures when compared with the uninjured contralateral side. Manual external rotation stress and gravity stress tests were performed on injured and uninjured ankles of ankle fracture patients in a clinic setting. Medial clear space measurements were recorded and differences between gravity and manual stress views were determined. Twenty consecutive patients with ankle injury were enrolled in the study. When compared with the uninjured side, gravity stress views showed a statistically significant (P = .017) increase in medial clear space widening (1.85 ± 1.07 mm) compared with manual stress view widening (1.35 ± 1.04 mm). This study suggests that gravity stress views are as effective as manual external rotation stress views in detecting medial clear space widening in isolated fibular fractures. Diagnostic, Level II: Prospective, comparative trial. © 2014 The Author(s).
The Utrecht questionnaire (U-CEP) measuring knowledge on clinical epidemiology proved to be valid.
Kortekaas, Marlous F; Bartelink, Marie-Louise E L; de Groot, Esther; Korving, Helen; de Wit, Niek J; Grobbee, Diederick E; Hoes, Arno W
2017-02-01
Knowledge on clinical epidemiology is crucial to practice evidence-based medicine. We describe the development and validation of the Utrecht questionnaire on knowledge on Clinical epidemiology for Evidence-based Practice (U-CEP); an assessment tool to be used in the training of clinicians. The U-CEP was developed in two formats: two sets of 25 questions and a combined set of 50. The validation was performed among postgraduate general practice (GP) trainees, hospital trainees, GP supervisors, and experts. Internal consistency, internal reliability (item-total correlation), item discrimination index, item difficulty, content validity, construct validity, responsiveness, test-retest reliability, and feasibility were assessed. The questionnaire was externally validated. Internal consistency was good with a Cronbach alpha of 0.8. The median item-total correlation and mean item discrimination index were satisfactory. Both sets were perceived as relevant to clinical practice. Construct validity was good. Both sets were responsive but failed on test-retest reliability. One set took 24 minutes and the other 33 minutes to complete, on average. External GP trainees had comparable results. The U-CEP is a valid questionnaire to assess knowledge on clinical epidemiology, which is a prerequisite for practicing evidence-based medicine in daily clinical practice. Copyright © 2016 Elsevier Inc. All rights reserved.
Kevern, Mark A.; Beecher, Michael; Rao, Smita
2014-01-01
Context: Athletes who participate in throwing and racket sports consistently demonstrate adaptive changes in glenohumeral-joint internal and external rotation in the dominant arm. Measurements of these motions have demonstrated excellent intrarater and poor interrater reliability. Objective: To determine intrarater reliability, interrater reliability, and standard error of measurement for shoulder internal rotation, external rotation, and total arc of motion using an inclinometer in 3 testing procedures in National Collegiate Athletic Association Division I baseball and softball athletes. Design: Cross-sectional study. Setting: Athletic department. Patients or Other Participants Thirty-eight players participated in the study. Shoulder internal rotation, external rotation, and total arc of motion were measured by 2 investigators in 3 test positions. The standard supine position was compared with a side-lying test position, as well as a supine test position without examiner overpressure. Results: Excellent intrarater reliability was noted for all 3 test positions and ranges of motion, with intraclass correlation coefficient values ranging from 0.93 to 0.99. Results for interrater reliability were less favorable. Reliability for internal rotation was highest in the side-lying position (0.68) and reliability for external rotation and total arc was highest in the supine-without-overpressure position (0.774 and 0.713, respectively). The supine-with-overpressure position yielded the lowest interrater reliability results in all positions. The side-lying position had the most consistent results, with very little variation among intraclass correlation coefficient values for the various test positions. Conclusions: The results of our study clearly indicate that the side-lying test procedure is of equal or greater value than the traditional supine-with-overpressure method. PMID:25188316
Achieving external validity in home advantage research: generalizing crowd noise effects
Myers, Tony D.
2014-01-01
Different factors have been postulated to explain the home advantage phenomenon in sport. One plausible explanation investigated has been the influence of a partisan home crowd on sports officials' decisions. Different types of studies have tested the crowd influence hypothesis including purposefully designed experiments. However, while experimental studies investigating crowd influences have high levels of internal validity, they suffer from a lack of external validity; decision-making in a laboratory setting bearing little resemblance to decision-making in live sports settings. This focused review initially considers threats to external validity in applied and theoretical experimental research. Discussing how such threats can be addressed using representative design by focusing on a recently published study that arguably provides the first experimental evidence of the impact of live crowd noise on officials in sport. The findings of this controlled experiment conducted in a real tournament setting offer a level of confirmation of the findings of laboratory studies in the area. Finally directions for future research and the future conduct of crowd noise studies are discussed. PMID:24917839
Quantitative structure-activity relationships for organophosphates binding to acetylcholinesterase.
Ruark, Christopher D; Hack, C Eric; Robinson, Peter J; Anderson, Paul E; Gearhart, Jeffery M
2013-02-01
Organophosphates are a group of pesticides and chemical warfare nerve agents that inhibit acetylcholinesterase, the enzyme responsible for hydrolysis of the excitatory neurotransmitter acetylcholine. Numerous structural variants exist for this chemical class, and data regarding their toxicity can be difficult to obtain in a timely fashion. At the same time, their use as pesticides and military weapons is widespread, which presents a major concern and challenge in evaluating human toxicity. To address this concern, a quantitative structure-activity relationship (QSAR) was developed to predict pentavalent organophosphate oxon human acetylcholinesterase bimolecular rate constants. A database of 278 three-dimensional structures and their bimolecular rates was developed from 15 peer-reviewed publications. A database of simplified molecular input line entry notations and their respective acetylcholinesterase bimolecular rate constants are listed in Supplementary Material, Table I. The database was quite diverse, spanning 7 log units of activity. In order to describe their structure, 675 molecular descriptors were calculated using AMPAC 8.0 and CODESSA 2.7.10. Orthogonal projection to latent structures regression, bootstrap leave-random-many-out cross-validation and y-randomization were used to develop an externally validated consensus QSAR model. The domain of applicability was assessed by the William's plot. Six external compounds were outside the warning leverage indicating potential model extrapolation. A number of compounds had residuals >2 or <-2, indicating potential outliers or activity cliffs. The results show that the HOMO-LUMO energy gap contributed most significantly to the binding affinity. A mean training R (2) of 0.80, a mean test set R (2) of 0.76 and a consensus external test set R (2) of 0.66 were achieved using the QSAR. The training and external test set RMSE values were found to be 0.76 and 0.88. The results suggest that this QSAR model can be used in physiologically based pharmacokinetic/pharmacodynamic models of organophosphate toxicity to determine the rate of acetylcholinesterase inhibition.
DFB laser - External modulator fiber optic delay line for radar applications
NASA Astrophysics Data System (ADS)
Newberg, I. L.; Gee, C. M.; Thurmond, G. D.; Yen, H. W.
1989-09-01
A new application of a long fiber-optic delay line as a radar repeater in a radar test set is described. The experimental 31.6-kilometer fiber-optic link includes an external modulator operating with a distributed-feedback laser and low-loss single-mode fiber matched to the laser wavelength to obtain low dispersion for achieving large bandwidth-length performance. The successful tests, in which pulse compression peak sidelobe measurements are used to confirm the link RF phase linearity and SNR performance, show that fiber-optic links can meet the stringent phase and noise requirements of modern radars at high microwave frequencies.
Robust tracking control of a magnetically suspended rigid body
NASA Technical Reports Server (NTRS)
Lim, Kyong B.; Cox, David E.
1994-01-01
This study is an application of H-infinity and micro-synthesis for designing robust tracking controllers for the Large Angle Magnetic Suspension Test Facility. The modeling, design, analysis, simulation, and testing of a control law that guarantees tracking performance under external disturbances and model uncertainties is investigated. The type of uncertainties considered and the tracking performance metric used is discussed. This study demonstrates the tradeoff between tracking performance at low frequencies and robustness at high frequencies. Two sets of controllers were designed and tested. The first set emphasized performance over robustness, while the second set traded off performance for robustness. Comparisons of simulation and test results are also included. Current simulation and experimental results indicate that reasonably good robust tracking performance can be attained for this system using multivariable robust control approach.
Verma, Rajeshwar P; Matthews, Edwin J
2015-03-01
This is part II of an in silico investigation of chemical-induced eye injury that was conducted at FDA's CFSAN. Serious eye damage caused by chemical (eye corrosion) is assessed using the rabbit Draize test, and this endpoint is an essential part of hazard identification and labeling of industrial and consumer products to ensure occupational and consumer safety. There is an urgent need to develop an alternative to the Draize test because EU's 7th amendment to the Cosmetic Directive (EC, 2003; 76/768/EEC) and recast Regulation now bans animal testing on all cosmetic product ingredients and EU's REACH Program limits animal testing for chemicals in commerce. Although in silico methods have been reported for eye irritation (reversible damage), QSARs specific for eye corrosion (irreversible damage) have not been published. This report describes the development of 21 ANN c-QSAR models (QSAR-21) for assessing eye corrosion potential of chemicals using a large and diverse CFSAN data set of 504 chemicals, ADMET Predictor's three sensitivity analyses and ANNE classification functionalities with 20% test set selection from seven different methods. QSAR-21 models were internally and externally validated and exhibited high predictive performance: average statistics for the training, verification, and external test sets of these models were 96/96/94% sensitivity and 91/91/90% specificity. Copyright © 2014 Elsevier Inc. All rights reserved.
Testing and operating a multiprocessor chip with processor redundancy
Bellofatto, Ralph E; Douskey, Steven M; Haring, Rudolf A; McManus, Moyra K; Ohmacht, Martin; Schmunkamp, Dietmar; Sugavanam, Krishnan; Weatherford, Bryan J
2014-10-21
A system and method for improving the yield rate of a multiprocessor semiconductor chip that includes primary processor cores and one or more redundant processor cores. A first tester conducts a first test on one or more processor cores, and encodes results of the first test in an on-chip non-volatile memory. A second tester conducts a second test on the processor cores, and encodes results of the second test in an external non-volatile storage device. An override bit of a multiplexer is set if a processor core fails the second test. In response to the override bit, the multiplexer selects a physical-to-logical mapping of processor IDs according to one of: the encoded results in the memory device or the encoded results in the external storage device. On-chip logic configures the processor cores according to the selected physical-to-logical mapping.
Lack of grading agreement among international hemostasis external quality assessment programs
Olson, John D.; Jennings, Ian; Meijer, Piet; Bon, Chantal; Bonar, Roslyn; Favaloro, Emmanuel J.; Higgins, Russell A.; Keeney, Michael; Mammen, Joy; Marlar, Richard A.; Meley, Roland; Nair, Sukesh C.; Nichols, William L.; Raby, Anne; Reverter, Joan C.; Srivastava, Alok; Walker, Isobel
2018-01-01
Laboratory quality programs rely on internal quality control and external quality assessment (EQA). EQA programs provide unknown specimens for the laboratory to test. The laboratory's result is compared with other (peer) laboratories performing the same test. EQA programs assign target values using a variety of methods statistical tools and performance assessment of ‘pass’ or ‘fail’ is made. EQA provider members of the international organization, external quality assurance in thrombosis and hemostasis, took part in a study to compare outcome of performance analysis using the same data set of laboratory results. Eleven EQA organizations using eight different analytical approaches participated. Data for a normal and prolonged activated partial thromboplastin time (aPTT) and a normal and reduced factor VIII (FVIII) from 218 laboratories were sent to the EQA providers who analyzed the data set using their method of evaluation for aPTT and FVIII, determining the performance for each laboratory record in the data set. Providers also summarized their statistical approach to assignment of target values and laboratory performance. Each laboratory record in the data set was graded pass/fail by all EQA providers for each of the four analytes. There was a lack of agreement of pass/fail grading among EQA programs. Discordance in the grading was 17.9 and 11% of normal and prolonged aPTT results, respectively, and 20.2 and 17.4% of normal and reduced FVIII results, respectively. All EQA programs in this study employed statistical methods compliant with the International Standardization Organization (ISO), ISO 13528, yet the evaluation of laboratory results for all four analytes showed remarkable grading discordance. PMID:29232255
Ivanic, Joseph; Schmidt, Michael W
2018-06-04
A novel hybrid correlation energy (HyCE) approach is proposed that determines the total correlation energy via distinct computation of its internal and external components. This approach evolved from two related studies. First, rigorous assessment of the accuracies and size extensivities of a number of electron correlation methods, that include perturbation theory (PT2), coupled-cluster (CC), configuration interaction (CI), and coupled electron pair approximation (CEPA), shows that the CEPA(0) variant of the latter and triples-corrected CC methods consistently perform very similarly. These findings were obtained by comparison to near full CI results for four small molecules and by charting recovered correlation energies for six steadily growing chain systems. Second, by generating valence virtual orbitals (VVOs) and utilizing the CEPA(0) method, we were able to partition total correlation energies into internal (or nondynamic) and external (or dynamic) parts for the aforementioned six chain systems and a benchmark test bed of 36 molecules. When using triple-ζ basis sets it was found that per orbital internal correlation energies were appreciably larger than per orbital external energies and that the former showed far more chemical variation than the latter. Additionally, accumulations of external correlation energies were seen to proceed smoothly, and somewhat linearly, as the virtual space is gradually increased. Combination of these two studies led to development of the HyCE approach, whereby the internal and external correlation energies are determined separately by CEPA(0)/VVO and PT2/external calculations, respectively. When applied to the six chain systems and the 36-molecule benchmark test set it was found that HyCE energies followed closely those of triples-corrected CC and CEPA(0) while easily outperforming MP2 and CCSD. The success of the HyCE approach is more notable when considering that its cost is only slightly more than MP2 and significantly cheaper than the CC approaches.
A new IRT-based standard setting method: application to eCat-listening.
García, Pablo Eduardo; Abad, Francisco José; Olea, Julio; Aguado, David
2013-01-01
Criterion-referenced interpretations of tests are highly necessary, which usually involves the difficult task of establishing cut scores. Contrasting with other Item Response Theory (IRT)-based standard setting methods, a non-judgmental approach is proposed in this study, in which Item Characteristic Curve (ICC) transformations lead to the final cut scores. eCat-Listening, a computerized adaptive test for the evaluation of English Listening, was administered to 1,576 participants, and the proposed standard setting method was applied to classify them into the performance standards of the Common European Framework of Reference for Languages (CEFR). The results showed a classification closely related to relevant external measures of the English language domain, according to the CEFR. It is concluded that the proposed method is a practical and valid standard setting alternative for IRT-based tests interpretations.
Ropodi, Athina I; Panagou, Efstathios Z; Nychas, George-John E
2018-01-01
In recent years, fraud detection has become a major priority for food authorities, as fraudulent practices can have various economic and safety consequences. This work explores ways of identifying frozen-then-thawed minced beef labeled as fresh in a rapid, large-scale and cost-effective way. For this reason, freshly-ground beef was purchased from seven separate shops at different times, divided in fifteen portions and placed in Petri dishes. Multi-spectral images and FTIR spectra of the first five were immediately acquired while the remaining were frozen (-20°C) and stored for 7 and 32days (5 samples for each time interval). Samples were thawed and subsequently subjected to similar data acquisition. In total, 105 multispectral images and FTIR spectra were collected which were further analyzed using partial least-squares discriminant analysis and support vector machines. Two meat batches (30 samples) were reserved for independent validation and the remaining five batches were divided in training and test set (75 samples). Results showed 100% overall correct classification for test and external validation MSI data, while FTIR data yielded 93.3 and 96.7% overall correct classification for FTIR test set and external validation set respectively. Copyright © 2017 Elsevier Ltd. All rights reserved.
Kong, Xiangxing; Li, Jun; Cai, Yibo; Tian, Yu; Chi, Shengqiang; Tong, Danyang; Hu, Yeting; Yang, Qi; Li, Jingsong; Poston, Graeme; Yuan, Ying; Ding, Kefeng
2018-01-08
To revise the American Joint Committee on Cancer TNM staging system for colorectal cancer (CRC) based on a nomogram analysis of Surveillance, Epidemiology, and End Results (SEER) database, and to prove the rationality of enhancing T stage's weighting in our previously proposed T-plus staging system. Total 115,377 non-metastatic CRC patients from SEER were randomly grouped as training and testing set by ratio 1:1. The Nomo-staging system was established via three nomograms based on 1-year, 2-year and 3-year disease specific survival (DSS) Logistic regression analysis of the training set. The predictive value of Nomo-staging system for the testing set was evaluated by concordance index (c-index), likelihood ratio (L.R.) and Akaike information criteria (AIC) for 1-year, 2-year, 3-year overall survival (OS) and DSS. Kaplan-Meier survival curve was used to valuate discrimination and gradient monotonicity. And an external validation was performed on database from the Second Affiliated Hospital of Zhejiang University (SAHZU). Patients with T1-2 N1 and T1N2a were classified into stage II while T4 N0 patients were classified into stage III in Nomo-staging system. Kaplan-Meier survival curves of OS and DSS in testing set showed Nomo-staging system performed better in discrimination and gradient monotonicity, and the external validation in SAHZU database also showed distinctly better discrimination. The Nomo-staging system showed higher value in L.R. and c-index, and lower value in AIC when predicting OS and DSS in testing set. The Nomo-staging system showed better performance in prognosis prediction and the weight of lymph nodes status in prognosis prediction should be cautiously reconsidered.
Lauer, Michael S; Pothier, Claire E; Magid, David J; Smith, S Scott; Kattan, Michael W
2007-12-18
The exercise treadmill test is recommended for risk stratification among patients with intermediate to high pretest probability of coronary artery disease. Posttest risk stratification is based on the Duke treadmill score, which includes only functional capacity and measures of ischemia. To develop and externally validate a post-treadmill test, multivariable mortality prediction rule for adults with suspected coronary artery disease and normal electrocardiograms. Prospective cohort study conducted from September 1990 to May 2004. Exercise treadmill laboratories in a major medical center (derivation set) and a separate HMO (validation set). 33,268 patients in the derivation set and 5821 in the validation set. All patients had normal electrocardiograms and were referred for evaluation of suspected coronary artery disease. The derivation set patients were followed for a median of 6.2 years. A nomogram-illustrated model was derived on the basis of variables easily obtained in the stress laboratory, including age; sex; history of smoking, hypertension, diabetes, or typical angina; and exercise findings of functional capacity, ST-segment changes, symptoms, heart rate recovery, and frequent ventricular ectopy in recovery. The derivation data set included 1619 deaths. Although both the Duke treadmill score and our nomogram-illustrated model were significantly associated with death (P < 0.001), the nomogram was better at discrimination (concordance index for right-censored data, 0.83 vs. 0.73) and calibration. We reclassified many patients with intermediate- to high-risk Duke treadmill scores as low risk on the basis of the nomogram. The model also predicted 3-year mortality rates well in the validation set: Based on an optimal cut-point for a negative predictive value of 0.97, derivation and validation rates were, respectively, 1.7% and 2.5% below the cut-point and 25% and 29% above the cut-point. Blood test-based measures or left ventricular ejection fraction were not included. The nomogram can be applied only to patients with a normal electrocardiogram. Clinical utility remains to be tested. A simple nomogram based on easily obtained pretest and exercise test variables predicted all-cause mortality in adults with suspected coronary artery disease and normal electrocardiograms.
The Standards Movement: A Child-Centered Response.
ERIC Educational Resources Information Center
Crain, William
2003-01-01
Discusses how child-centered educational philosophies, including Montessori, share positions differing radically from those of the educational standards movement. Focuses on adult-set goals and standards, social promotion, external motivators, demands for more challenging work, and standardized tests. Reports that children in child-centered…
Prediction of biodegradability from chemical structure: Modeling or ready biodegradation test data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Loonen, H.; Lindgren, F.; Hansen, B.
1999-08-01
Biodegradation data were collected and evaluated for 894 substances with widely varying chemical structures. All data were determined according to the Japanese Ministry of International Trade and Industry (MITI) I test protocol. The MITI I test is a screening test for ready biodegradability and has been described by Organization for Economic Cooperation and Development (OECD) test guideline 301 C and European Union (EU) test guideline C4F. The chemicals were characterized by a set of 127 predefined structural fragments. This data set was used to develop a model for the prediction of the biodegradability of chemicals under standardized OECD and EUmore » ready biodegradation test conditions. Partial least squares (PLS) discriminant analysis was used for the model development. The model was evaluated by means of internal cross-validation and repeated external validation. The importance of various structural fragments and fragment interactions was investigated. The most important fragments include the presence of a long alkyl chain; hydroxy, ester, and acid groups (enhancing biodegradation); and the presence of one or more aromatic rings and halogen substituents (regarding biodegradation). More than 85% of the model predictions were correct for using the complete data set. The not readily biodegradable predictions were slightly better than the readily biodegradable predictions (86 vs 84%). The average percentage of correct predictions from four external validation studies was 83%. Model optimization by including fragment interactions improve the model predicting capabilities to 89%. It can be concluded that the PLS model provides predictions of high reliability for a diverse range of chemical structures. The predictions conform to the concept of readily biodegradable (or not readily biodegradable) as defined by OECD and EU test guidelines.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-16
...): The capability to interface with external devices over a high bandwidth network (e.g., IEEE 802.11 (WiFi), MoCA, HPNA). For purposes of this specification, IEEE 802.3 wired Ethernet is not considered a...
Effects of a PID Control System on Electromagnetic Fields in an nEDM Experiment
NASA Astrophysics Data System (ADS)
Molina, Daniel
2017-09-01
The Kellogg Radiation Laboratory is currently testing a prototype for an experiment that hopes to identify the electric dipole moment of the neutron. As part of this testing, we have developed a PID (proportional, integral, derivative) feedback system that uses large coils to fix the value of local external magnetic fields, up to linear gradients. PID algorithms compare the current value to a set-point and use the integral and derivative of the field with respect to the set-point to maintain constant fields. We have also developed a method for zeroing linear gradients within the experimental apparatus. In order to determine the performance of the PID algorithm, measurements of both the internal and external fields were obtained with and without the algorithm running, and these results were compared for noise and time stability. We have seen that the PID algorithm can reduce the effect of disturbance to the field by a factor of 10.
Design of sEMG assembly to detect external anal sphincter activity: a proof of concept.
Shiraz, Arsam; Leaker, Brian; Mosse, Charles Alexander; Solomon, Eskinder; Craggs, Michael; Demosthenous, Andreas
2017-10-31
Conditional trans-rectal stimulation of the pudendal nerve could provide a viable solution to treat hyperreflexive bladder in spinal cord injury. A set threshold of the amplitude estimate of the external anal sphincter surface electromyography (sEMG) may be used as the trigger signal. The efficacy of such a device should be tested in a large scale clinical trial. As such, a probe should remain in situ for several hours while patients attend to their daily routine; the recording electrodes should be designed to be large enough to maintain good contact while observing design constraints. The objective of this study was to arrive at a design for intra-anal sEMG recording electrodes for the subsequent clinical trials while deriving the possible recording and processing parameters. Having in mind existing solutions and based on theoretical and anatomical considerations, a set of four multi-electrode probes were designed and developed. These were tested in a healthy subject and the measured sEMG traces were recorded and appropriately processed. It was shown that while comparatively large electrodes record sEMG traces that are not sufficiently correlated with the external anal sphincter contractions, smaller electrodes may not maintain a stable electrode tissue contact. It was shown that 3 mm wide and 1 cm long electrodes with 5 mm inter-electrode spacing, in agreement with Nyquist sampling, placed 1 cm from the orifice may intra-anally record a sEMG trace sufficiently correlated with external anal sphincter activity. The outcome of this study can be used in any biofeedback, treatment or diagnostic application where the activity of the external anal sphincter sEMG should be detected for an extended period of time.
Coley, Rebekah Levine; Kull, Melissa A; Carrano, Jennifer
2014-02-01
This study assessed prospective, bidirectional associations between maternal endorsement of spanking and children's internalizing and externalizing behavior problems in low-income urban African American and Hispanic (N = 592) families drawn from the Three City Study. Children in sample families were followed from early childhood through middle childhood with 3 sets of interviews and assessments at ages 3, 4, and 9 years. Cross-lagged path analyses tested longitudinal bidirectional associations between parental endorsement of spanking and children's internalizing and externalizing problems, with multigroup comparisons employed to test group differences between race/ethnic groups. African American and Hispanic mothers showed similar endorsements of spanking. Results suggest that associations between spanking endorsement and child functioning were due primarily to parenting effects, with spanking predicting changes in children's behaviors, rather than child evocative effects, with limited evidence of child behaviors predicting changes in parental spanking. Maternal spanking endorsement predicted short-term decreases in children's internalizing problems in early childhood, but over the longer term spanking was associated with increased internalizing and externalizing problems for both African American and Hispanic children in middle childhood among economically disadvantaged families.
An External Archive-Guided Multiobjective Particle Swarm Optimization Algorithm.
Zhu, Qingling; Lin, Qiuzhen; Chen, Weineng; Wong, Ka-Chun; Coello Coello, Carlos A; Li, Jianqiang; Chen, Jianyong; Zhang, Jun
2017-09-01
The selection of swarm leaders (i.e., the personal best and global best), is important in the design of a multiobjective particle swarm optimization (MOPSO) algorithm. Such leaders are expected to effectively guide the swarm to approach the true Pareto optimal front. In this paper, we present a novel external archive-guided MOPSO algorithm (AgMOPSO), where the leaders for velocity update are all selected from the external archive. In our algorithm, multiobjective optimization problems (MOPs) are transformed into a set of subproblems using a decomposition approach, and then each particle is assigned accordingly to optimize each subproblem. A novel archive-guided velocity update method is designed to guide the swarm for exploration, and the external archive is also evolved using an immune-based evolutionary strategy. These proposed approaches speed up the convergence of AgMOPSO. The experimental results fully demonstrate the superiority of our proposed AgMOPSO in solving most of the test problems adopted, in terms of two commonly used performance measures. Moreover, the effectiveness of our proposed archive-guided velocity update method and immune-based evolutionary strategy is also experimentally validated on more than 30 test MOPs.
3T magnetic resonance imaging testing of externally programmable shunt valves
Zabramski, Joseph M.; Preul, Mark C.; Debbins, Josef; McCusker, Daniel J.
2012-01-01
Background: Exposure of externally programmable shunt-valves (EPS-valves) to magnetic resonance imaging (MRI) may lead to unexpected changes in shunt settings, or affect the ability to reprogram the valve. We undertook this study to examine the effect of exposure to a 3T MRI on a group of widely used EPS-valves. Methods: Evaluations were performed on first generation EPS-valves (those without a locking mechanism to prevent changes in shunt settings by external magnets other than the programmer) and second generation EPS-valves (those with a locking mechanisms). Fifteen new shunt-valves were divided into five groups of three identical valves each, and then exposed to a series of six simulated MRI scans. After each of the exposures, the valves were evaluated to determine if the valve settings had changed, and whether the valves could be reprogrammed. The study produced 18 evaluations for each line of shunt-valves. Results: Exposure of the first generation EPS-valves to a 3T magnetic field resulted in frequent changes in the valve settings; however, all valves retained their ability to be reprogrammed. Repeated exposure of the second generation EPS-valves has no effect on shunt valve settings, and all valves retained their ability to be interrogated and reprogrammed. Conclusions: Second generation EPS-valves with locking mechanisms can be safely exposed to repeated 3T MRI systems, without evidence that shunt settings will change. The exposure of the first generation EPS-valves to 3T MRI results in frequent changes in shunt settings that necessitate re-evaluation soon after MRI to avoid complications. PMID:22937481
Kang, Yun-Seok; Bolte, John H; Moorhouse, Kevin; Donnelly, Bruce; Herriott, Rodney; Mallory, Ann
2012-10-01
The objectives of this study were to obtain biomechanical responses of post mortem human subjects (PMHS) by subjecting them to two moderate-speed rear impact sled test conditions (8.5g, 17 km/h; 10.5g, 24 km/h) while positioned in an experimental seat system, and to create biomechanical targets for internal and external biofidelity evaluation of rear impact ATDs. The experimental seat was designed to measure external loads on the head restraint (4 load cells), seat back (6 load cells), and seat pan (4 load cells) such that subject dynamic interaction with the seat could be evaluated. This seat system was capable of simulating the dynamic characteristics of modern vehicle seat backs by considering the moment-rotation properties of a typical passenger vehicle, thus providing a more realistic test environment than using a rigid seat with a non-rotating seat back as done in previous studies. Instrumentation used to measure biomechanical responses of the PMHS included both accelerometers and angular rate sensors (ARS). A total of fourteen sled tests using eight PMHS (males 175.8 ± 6.2 cm of stature and 78.4 ± 7.2 kg of weight) provided data sets of seven PMHS for both test conditions. The biomechanical responses are described at both speeds, and cervical spine injuries are documented. Biomechanical targets are also created for internal and external biofidelity evaluation of rear impact anthropomorphic test devices (ATDs).
2016-01-01
It is important to consider the role of diagnostics and the critical need for quality diagnostics services in resource-limited settings. Accurate diagnostic tests play a key role in patient management and the prevention and control of most infectious diseases. As countries plan for implementation of HIV early infant diagnosis and viral load point-of-care testing, the London School of Hygiene & Tropical Medicine has worked with countries and partners with an interest in external quality assurance to support quality point-of-care testing on the continent. Through a series of collaborative consultations and workshops, the London School of Hygiene & Tropical Medicine has gathered lessons learned, tools, and resources and developed quality assurance models that will support point-of-care testing. The London School of Hygiene & Tropical Medicine is committed to the continued advancement of laboratory diagnostics in Africa and quality laboratory services and point-of-care testing. PMID:28879132
Votano, Joseph R; Parham, Marc; Hall, L Mark; Hall, Lowell H; Kier, Lemont B; Oloff, Scott; Tropsha, Alexander
2006-11-30
Four modeling techniques, using topological descriptors to represent molecular structure, were employed to produce models of human serum protein binding (% bound) on a data set of 1008 experimental values, carefully screened from publicly available sources. To our knowledge, this data is the largest set on human serum protein binding reported for QSAR modeling. The data was partitioned into a training set of 808 compounds and an external validation test set of 200 compounds. Partitioning was accomplished by clustering the compounds in a structure descriptor space so that random sampling of 20% of the whole data set produced an external test set that is a good representative of the training set with respect to both structure and protein binding values. The four modeling techniques include multiple linear regression (MLR), artificial neural networks (ANN), k-nearest neighbors (kNN), and support vector machines (SVM). With the exception of the MLR model, the ANN, kNN, and SVM QSARs were ensemble models. Training set correlation coefficients and mean absolute error ranged from r2=0.90 and MAE=7.6 for ANN to r2=0.61 and MAE=16.2 for MLR. Prediction results from the validation set yielded correlation coefficients and mean absolute errors which ranged from r2=0.70 and MAE=14.1 for ANN to a low of r2=0.59 and MAE=18.3 for the SVM model. Structure descriptors that contribute significantly to the models are discussed and compared with those found in other published models. For the ANN model, structure descriptor trends with respect to their affects on predicted protein binding can assist the chemist in structure modification during the drug design process.
Aerodynamic heating to representative SRB and ET protuberances
NASA Technical Reports Server (NTRS)
Engel, C. D.; Lapointe, J. K.
1979-01-01
Heating data and data scaling methods which can be used on representative solid rocket booster and external tank (ET) protuberances are described. Topics covered include (1) ET geometry and heating points; (2) interference heating test data (51A); (3) heat transfer data from tests FH-15 and FH-16; (4) individual protuberance data; and (5) interference heating of paint data from test IH-42. A set of drawings of the ET moldline and protuberances is included.
Choo, Min Soo; Jeong, Seong Jin; Cho, Sung Yong; Yoo, Changwon; Jeong, Chang Wook; Ku, Ja Hyeon; Oh, Seung-June
2017-04-01
We aimed to externally validate the prediction model we developed for having bladder outlet obstruction (BOO) and requiring prostatic surgery using 2 independent data sets from tertiary referral centers, and also aimed to validate a mobile app for using this model through usability testing. Formulas and nomograms predicting whether a subject has BOO and needs prostatic surgery were validated with an external validation cohort from Seoul National University Bundang Hospital and Seoul Metropolitan Government-Seoul National University Boramae Medical Center between January 2004 and April 2015. A smartphone-based app was developed, and 8 young urologists were enrolled for usability testing to identify any human factor issues of the app. A total of 642 patients were included in the external validation cohort. No significant differences were found in the baseline characteristics of major parameters between the original (n=1,179) and the external validation cohort, except for the maximal flow rate. Predictions of requiring prostatic surgery in the validation cohort showed a sensitivity of 80.6%, a specificity of 73.2%, a positive predictive value of 49.7%, and a negative predictive value of 92.0%, and area under receiver operating curve of 0.84. The calibration plot indicated that the predictions have good correspondence. The decision curve showed also a high net benefit. Similar evaluation results using the external validation cohort were seen in the predictions of having BOO. Overall results of the usability test demonstrated that the app was user-friendly with no major human factor issues. External validation of these newly developed a prediction model demonstrated a moderate level of discrimination, adequate calibration, and high net benefit gains for predicting both having BOO and requiring prostatic surgery. Also a smartphone app implementing the prediction model was user-friendly with no major human factor issue.
Lee, Jung Keun; Park, Edward J.; Robinovitch, Stephen N.
2012-01-01
This paper proposes a Kalman filter-based attitude (i.e., roll and pitch) estimation algorithm using an inertial sensor composed of a triaxial accelerometer and a triaxial gyroscope. In particular, the proposed algorithm has been developed for accurate attitude estimation during dynamic conditions, in which external acceleration is present. Although external acceleration is the main source of the attitude estimation error and despite the need for its accurate estimation in many applications, this problem that can be critical for the attitude estimation has not been addressed explicitly in the literature. Accordingly, this paper addresses the combined estimation problem of the attitude and external acceleration. Experimental tests were conducted to verify the performance of the proposed algorithm in various dynamic condition settings and to provide further insight into the variations in the estimation accuracy. Furthermore, two different approaches for dealing with the estimation problem during dynamic conditions were compared, i.e., threshold-based switching approach versus acceleration model-based approach. Based on an external acceleration model, the proposed algorithm was capable of estimating accurate attitudes and external accelerations for short accelerated periods, showing its high effectiveness during short-term fast dynamic conditions. Contrariwise, when the testing condition involved prolonged high external accelerations, the proposed algorithm exhibited gradually increasing errors. However, as soon as the condition returned to static or quasi-static conditions, the algorithm was able to stabilize the estimation error, regaining its high estimation accuracy. PMID:22977288
Xu, Chuan; Huang, Xin-En; Wang, Shu-Xiang; Lv, Peng-Hua; Sun, Ling; Wang, Fu-An
2015-01-01
Percutaneous transhepatic biliary drainage (PTBD) is a form of palliative care for patients with malignant obstructive jaundice. We here compared the infection incidence between internal-external and external drainage for patients with malignant obstructive jaundice. Patients with malignant obstructive jaundice without infection before surgery receiving internal-external or external drainage from January 2008 to July 2014 were recruited. According to percutaneous transhepatic cholangiography (PTC), if the guide wire could pass through the occlusion and enter the duodenum, we recommended internal-external drainage, and external drainage biliary drainage was set up if the occlusion was not crossed. All patients with infection after procedure received a cultivation of blood and a bile bacteriological test. Among 110 patients with malignant obstructive jaundice, 22 (52.4%) were diagnosed with infection after the procedure in the internal-external drainage group, whereas 19 (27.9%) patients were so affected in the external drainage group, the difference being significant (p<0.05). In 8 patients (36.3%) in the internal-external group infection was controlled, as compared to 12 (63.1%) in the external group (p<0.05). The mortality rate for patients with infection not controlled in internal-external group in one month was 42.8%, while this rate in external group was 28.6% (p<0.05). External drainage is a good choice, which could significantly reduce the chance of biliary infection caused by bacteria, and decrease the mortality rate at one month and improve the long-term prognosis.
QSAR study of curcumine derivatives as HIV-1 integrase inhibitors.
Gupta, Pawan; Sharma, Anju; Garg, Prabha; Roy, Nilanjan
2013-03-01
A QSAR study was performed on curcumine derivatives as HIV-1 integrase inhibitors using multiple linear regression. The statistically significant model was developed with squared correlation coefficients (r(2)) 0.891 and cross validated r(2) (r(2) cv) 0.825. The developed model revealed that electronic, shape, size, geometry, substitution's information and hydrophilicity were important atomic properties for determining the inhibitory activity of these molecules. The model was also tested successfully for external validation (r(2) pred = 0.849) as well as Tropsha's test for model predictability. Furthermore, the domain analysis was carried out to evaluate the prediction reliability of external set molecules. The model was statistically robust and had good predictive power which can be successfully utilized for screening of new molecules.
In Vitro Bioactivity in ToxCast Assays for Fruit and Vegetable Juices (TDS)
The ToxCast and Tox21 programs have generated in vitro screening data for over 1000 chemicals to aid in hazard identification and setting chemical testing priorities. These data, together with in vitro pharmacokinetic data, are used to infer possible toxic responses and external ...
Camus, Melinda S; Flatland, Bente; Freeman, Kathleen P; Cruz Cardona, Janice A
2015-12-01
The purpose of this document is to educate providers of veterinary laboratory diagnostic testing in any setting about comparative testing. These guidelines will define, explain, and illustrate the importance of a multi-faceted laboratory quality management program which includes comparative testing. The guidelines will provide suggestions for implementation of such testing, including which samples should be tested, frequency of testing, and recommendations for result interpretation. Examples and a list of vendors and manufacturers supplying control materials and services to veterinary laboratories are also included. © 2015 American Society for Veterinary Clinical Pathology.
Spackman, Erica; Cardona, Carol; Muñoz-Aguayo, Jeannette; Fleming, Susan
2016-01-01
The US National institutes of Health-Centers of Excellence for Influenza Research and Surveillance is a research consortium that funds numerous labs worldwide to conduct influenza A surveillance in diverse animal species. There is no harmonization of testing procedures among these labs; therefore an external quality assurance (EQA) program was implemented to evaluate testing accuracy among labs in the program in 2012. Accurate detection of novel influenza A variants is crucial because of the broad host range and potentially high virulence of the virus in diverse species. Two molecular detection sample sets and 2 serology sample sets (one with avian origin isolates, and one with mammalian origin isolates each) were made available at approximately six month intervals. Participating labs tested the material in accordance with their own protocols. During a five year period a total of 41 labs from 23 countries ordered a total of 132 avian molecular, 121 mammalian molecular and 90 serology sample sets. Testing was completed by 111 individuals. Detection of type A influenza by RT-PCR was reliable with a pass rate (80% or greater agreement with expected results) of 86.6% for avian and 86.2% for mammalian origin isolates. However, identification of subtype by RT-PCR was relatively poor with 54.1% and 75.9% accuracy for avian and mammalian influenza isolates respectively. Serological testing had an overall pass rate of 86.9% and 22/23 labs used commercial ELISA kits. Based on the results of this EQA program six labs modified their procedures to improve accuracy and one lab identified an unknown equipment problem. These data represent the successful implementation of an international EQA program for an infectious disease; insights into the logistics and test design are also discussed. PMID:27788155
Spackman, Erica; Cardona, Carol; Muñoz-Aguayo, Jeannette; Fleming, Susan
2016-01-01
The US National institutes of Health-Centers of Excellence for Influenza Research and Surveillance is a research consortium that funds numerous labs worldwide to conduct influenza A surveillance in diverse animal species. There is no harmonization of testing procedures among these labs; therefore an external quality assurance (EQA) program was implemented to evaluate testing accuracy among labs in the program in 2012. Accurate detection of novel influenza A variants is crucial because of the broad host range and potentially high virulence of the virus in diverse species. Two molecular detection sample sets and 2 serology sample sets (one with avian origin isolates, and one with mammalian origin isolates each) were made available at approximately six month intervals. Participating labs tested the material in accordance with their own protocols. During a five year period a total of 41 labs from 23 countries ordered a total of 132 avian molecular, 121 mammalian molecular and 90 serology sample sets. Testing was completed by 111 individuals. Detection of type A influenza by RT-PCR was reliable with a pass rate (80% or greater agreement with expected results) of 86.6% for avian and 86.2% for mammalian origin isolates. However, identification of subtype by RT-PCR was relatively poor with 54.1% and 75.9% accuracy for avian and mammalian influenza isolates respectively. Serological testing had an overall pass rate of 86.9% and 22/23 labs used commercial ELISA kits. Based on the results of this EQA program six labs modified their procedures to improve accuracy and one lab identified an unknown equipment problem. These data represent the successful implementation of an international EQA program for an infectious disease; insights into the logistics and test design are also discussed.
Fuller, J Bryan; Marler, Laura; Hester, Kim; Frey, Len; Relyea, Clint
2006-12-01
According to Social Identity Theory (cf., J. G. March & H. A. Simon, 1958), individuals tend to identify with prestigious or high-status groups. Researchers (J. E. Dutton, J. M. Dukerich, & C. V. Harquail, 1994) have revealed that organizational members also identify with organizations that have attractive public images. To gain a better understanding of the theoretical reasons underlying the relationship between image and identification in organizations, the authors examined this relationship in a healthcare setting. In addition, they investigated need for esteem as a moderator of the relationship between construed external image and organizational identification. Consistent with previous findings, the present results indicated that construed external image is positively related to organizational identification. Perhaps it is more important that the present findings also supported need for esteem as a moderator of the relationship between construed external image and organizational identification.
QSAR models for thiophene and imidazopyridine derivatives inhibitors of the Polo-Like Kinase 1.
Comelli, Nieves C; Duchowicz, Pablo R; Castro, Eduardo A
2014-10-01
The inhibitory activity of 103 thiophene and 33 imidazopyridine derivatives against Polo-Like Kinase 1 (PLK1) expressed as pIC50 (-logIC50) was predicted by QSAR modeling. Multivariate linear regression (MLR) was employed to model the relationship between 0D and 3D molecular descriptors and biological activities of molecules using the replacement method (MR) as variable selection tool. The 136 compounds were separated into several training and test sets. Two splitting approaches, distribution of biological data and structural diversity, and the statistical experimental design procedure D-optimal distance were applied to the dataset. The significance of the training set models was confirmed by statistically higher values of the internal leave one out cross-validated coefficient of determination (Q2) and external predictive coefficient of determination for the test set (Rtest2). The model developed from a training set, obtained with the D-optimal distance protocol and using 3D descriptor space along with activity values, separated chemical features that allowed to distinguish high and low pIC50 values reasonably well. Then, we verified that such model was sufficient to reliably and accurately predict the activity of external diverse structures. The model robustness was properly characterized by means of standard procedures and their applicability domain (AD) was analyzed by leverage method. Copyright © 2014 Elsevier B.V. All rights reserved.
2007-12-15
KENNEDY SPACE CENTER, FLA. -- On Launch Pad 39A at NASA's Kennedy Space Center, the wiring is checked and validated before the tanking test on space shuttle Atlantis' external tank set for Dec. 18. The test wiring has been spliced into an electrical harness in the aft main engine compartment connected with the engine cut-off, or ECO, sensor system. The attached wiring leads to the interior of the mobile launcher platform where the time domain reflectometry, or TDR, test equipment is located. Photo credit: NASA/Kim Shiflett
2007-12-15
KENNEDY SPACE CENTER, FLA. -- On Launch Pad 39A at NASA's Kennedy Space Center, the wiring is checked and validated before the tanking test on space shuttle Atlantis' external tank set for Dec. 18. The test wiring has been spliced into an electrical harness in the aft main engine compartment connected with the engine cut-off, or ECO, sensor system. The attached wiring leads to the interior of the mobile launcher platform where the time domain reflectometry, or TDR, test equipment is located. Photo credit: NASA/Kim Shiflett
2007-12-15
KENNEDY SPACE CENTER, FLA. -- On Launch Pad 39A at NASA's Kennedy Space Center, the wiring is checked and validated before the tanking test on space shuttle Atlantis' external tank set for Dec. 18. The test wiring has been spliced into an electrical harness in the aft main engine compartment connected with the engine cut-off, or ECO, sensor system. The attached wiring leads to the interior of the mobile launcher platform where the time domain reflectometry, or TDR, test equipment is located. Photo credit: NASA/Kim Shiflett
2007-12-15
KENNEDY SPACE CENTER, FLA. -- On Launch Pad 39A at NASA's Kennedy Space Center, the wiring is checked and validated before the tanking test on space shuttle Atlantis' external tank set for Dec. 18. The test wiring has been spliced into an electrical harness in the aft main engine compartment connected with the engine cut-off, or ECO, sensor system. The attached wiring leads to the interior of the mobile launcher platform where the time domain reflectometry, or TDR, test equipment is located. Photo credit: NASA/Kim Shiflett
2007-12-15
KENNEDY SPACE CENTER, FLA. -- On Launch Pad 39A at NASA's Kennedy Space Center, the wiring is checked and validated before the tanking test on space shuttle Atlantis' external tank set for Dec. 18. The test wiring has been spliced into an electrical harness in the aft main engine compartment connected with the engine cut-off, or ECO, sensor system. The attached wiring leads to the interior of the mobile launcher platform where the time domain reflectometry, or TDR, test equipment is located. Photo credit: NASA/Kim Shiflett
External cooling methods for treatment of fever in adults: a systematic review.
Chan, E Y; Chen, W T; Assam, P N
It is unclear if the use of external cooling to treat fever contributes to better patient outcomes. Despite this, it is a common practice to treat febrile patients using external cooling methods alone or in combination with pharmacological antipyretics. The objective of this systematic review was to evaluate the effectiveness and complications of external cooling methods in febrile adults in acute care settings. We included adults admitted to acute care settings and developed elevated body temperature.We considered any external cooling method compared to no cooling.We considered randomised control trials (RCTs), quasi-randomised trials and controlled trials with concurrent control groups SEARCH STRATEGY: We searched relevant published or unpublished studies up to October 2009 regardless of language. We searched major databases, reference lists, bibliographies of all relevant articles, and contacted experts in the field for additional studies. Two reviewers independently screened titles and abstracts, and retrieved all potentially relevant studies. Two reviewers independently conducted the assessment of methodological quality of included studies. The results of studies where appropriate was quantitatively summarised. Relative risks or weighted mean difference and their 95% confidence intervals were calculated using the random effects model in Review Manager 5. For each pooled comparison, heterogeneity was assessed using the chi-squared test at the 5% level of statistical significance, with I statistic used to assess the impact of statistical heterogeneity on study results. Where statistical summary was not appropriate or possible, the findings were summarised in narrative form. We found six RCTs that compared the effectiveness and complications of external cooling methods against no external cooling. There was wide variation in the outcome measures between the included trials. We performed meta-analyses on data from two RCTs totalling 356 patients testing external cooling combined with antipyretics versus antipyretics alone, for the resolution of fever. The results did not show a statistically significant reduction in fever (relative risk 1.12, 95% CI 0.95 to 1.31; P=0.35; I =0%).The evidence from four trials suggested that there was no difference in the mean drop in body temperature post treatment initiation, between external cooling and no cooling groups. The results of most other outcomes also did not demonstrate a statistically significant difference. However summarising the results of five trials consisting of 371 patients found that the external cooling group was more likely to shiver when compared to the no cooling group (relative risk 6.37, 95% CI 2.01 to 20.11; P=0.61; I =0%).Overall this review suggested that external cooling methods (whether used alone or in combination with pharmacologic methods) were not effective in treating fever among adults admitted to acute care settings. Yet they were associated with higher incidences of shivering. These results should be interpreted in light of the methodological limitations of available trials. Given the current available evidence, the routine use of external cooling methods to treat fever in adults may not be warranted until further evidence is available. They could be considered for patients whose conditions are unable to tolerate even slight increase in temperature or who request for them. Whenever they are used, shivering should be prevented. Well-designed, adequately powered, randomised trials comparing external cooling methods against no cooling are needed.
Coley, Rebekah Levine; Kull, Melissa A.; Carrano, Jennifer
2014-01-01
This study assessed prospective, bidirectional associations between maternal endorsement of spanking and children’s internalizing and externalizing behavior problems in low-income urban African American and Hispanic (N = 592) families drawn from the Three City Study. Children in sample families were followed from early childhood through middle childhood with three sets of interviews and assessments at ages 3, 4, and 9 years. Cross-lagged path analyses tested longitudinal bidirectional associations between parental endorsement of spanking and children’s internalizing and externalizing problems, with multi-group comparisons employed to test group differences between race/ethnic groups. African American and Hispanic mothers showed similar endorsements of spanking. Results suggest that associations between spanking endorsement and child functioning were due primarily to parenting effects, with spanking predicting changes in children’s behaviors, rather than child evocative effects, with limited evidence of child behaviors predicting changes in parental spanking. Maternal spanking endorsement predicted short-term decreases in children’s internalizing problems in early childhood, but over the longer term spanking was associated with increased internalizing and externalizing problems for both African American and Hispanic children in middle childhood among economically disadvantaged families. PMID:24364363
NASA Astrophysics Data System (ADS)
Ahmadi Nadooshan, Afshin; Kalbasi, Rasool; Afrand, Masoud
2018-04-01
Perforated fins effects on the heat transfer rate of a circular tube are examined experimentally. An experimental system is set up through the wind tunnel and equipped with necessary measurement tools. Hot water passes through the finned tube and heat transfers to the fin-side air created using the wind tunnel with different velocities. Two fin sets of identical weight are installed on a circular tube with different outer diameters of 22 and 26 mm. The experiments are conducted at two different mass flow rates of the hot water and six Reynolds number of external air flow. Considering the four finned tubes and one no finned tube, a total of 60 tests are conducted. Results showed that with increasing the internal or external flow rates, the effect of larger cross-sectional area is greater. By opening holes on the fins, in addition to weight loss, the maximum heat transfer rate for perforated fins increases by 8.78% and 9.23% respectively for mass flow rates of 0.05 and 0.1 kg/s at low external Reynolds number. While, at high external Reynolds number, the holes reduces heat transfer by 8.4% and 10.6% for mass flow rates of 0.05 and 0.1 kg/s, respectively.
A quality management systems approach for CD4 testing in resource-poor settings.
Westerman, Larry E; Kohatsu, Luciana; Ortiz, Astrid; McClain, Bernice; Kaplan, Jonathan; Spira, Thomas; Marston, Barbara; Jani, Ilesh V; Nkengasong, John; Parsons, Linda M
2010-10-01
Quality assurance (QA) is a systematic process to monitor and improve clinical laboratory practices. The fundamental components of a laboratory QA program include providing a functional and safe laboratory environment, trained and competent personnel, maintained equipment, adequate supplies and reagents, testing of appropriate specimens, internal monitoring of quality, accurate reporting, and external quality assessments. These components are necessary to provide accurate and precise CD4 T-cell counts, an essential test to evaluate start of and monitor effectiveness of antiretroviral therapy for HIV-infected patients. In recent years, CD4 testing has expanded dramatically in resource-limited settings. Information on a CD4 QA program as described in this article will provide guidelines not only for clinical laboratory staff but also for managers of programs responsible for supporting CD4 testing. All agencies involved in implementing CD4 testing must understand the needs of the laboratory and provide advocacy, guidance, and financial support to established CD4 testing sites and programs. This article describes and explains the procedures that must be put in place to provide reliable CD4 determinations in a variety of settings.
National Testing of Pupils in Europe: Objectives, Organisation and Use of Results. Greece 2009
ERIC Educational Resources Information Center
Eurydice, 2009
2009-01-01
Pupil assessment procedures and methods in Greece are set and "standardized" externally by the central authorities as defined in the legislative framework, the National Curriculum guidelines and teachers' manuals, while implementation is internal to the schools. The focus of primary schools is on formative assessment, while the lower…
ERIC Educational Resources Information Center
Maruska, K.; Morgenstern, M.; Isensee, B.; Hanewinkel, R.
2010-01-01
Effects of the life skills programme "Eigenstandig werden" (Becoming independent) on life skills and on identified antecedents of adolescent health risk behaviour, childhood internalizing and externalizing behaviour were tested in an elementary school setting. A quasi-experimental controlled trial with five repeated measures was…
Exploring the Affective Dimension of Teachers' Work in Alternative School Settings
ERIC Educational Resources Information Center
te Riele, Kitty; Mills, Martin; McGregor, Glenda; Baroutsis, Aspa
2017-01-01
The affective dimension of teachers' work is a vital element in shaping inclusive, child-centred classrooms. It is particularly important for students who lack certain aspects of care and support within their personal lives. Recently, neoliberal educational paradigms of data gathering, external testing and competition have increased pressure upon…
Fang, Jiansong; Yang, Ranyao; Gao, Li; Zhou, Dan; Yang, Shengqian; Liu, Ai-Lin; Du, Guan-hua
2013-11-25
Butyrylcholinesterase (BuChE, EC 3.1.1.8) is an important pharmacological target for Alzheimer's disease (AD) treatment. However, the currently available BuChE inhibitor screening assays are expensive, labor-intensive, and compound-dependent. It is necessary to develop robust in silico methods to predict the activities of BuChE inhibitors for the lead identification. In this investigation, support vector machine (SVM) models and naive Bayesian models were built to discriminate BuChE inhibitors (BuChEIs) from the noninhibitors. Each molecule was initially represented in 1870 structural descriptors (1235 from ADRIANA.Code, 334 from MOE, and 301 from Discovery studio). Correlation analysis and stepwise variable selection method were applied to figure out activity-related descriptors for prediction models. Additionally, structural fingerprint descriptors were added to improve the predictive ability of models, which were measured by cross-validation, a test set validation with 1001 compounds and an external test set validation with 317 diverse chemicals. The best two models gave Matthews correlation coefficient of 0.9551 and 0.9550 for the test set and 0.9132 and 0.9221 for the external test set. To demonstrate the practical applicability of the models in virtual screening, we screened an in-house data set with 3601 compounds, and 30 compounds were selected for further bioactivity assay. The assay results showed that 10 out of 30 compounds exerted significant BuChE inhibitory activities with IC50 values ranging from 0.32 to 22.22 μM, at which three new scaffolds as BuChE inhibitors were identified for the first time. To our best knowledge, this is the first report on BuChE inhibitors using machine learning approaches. The models generated from SVM and naive Bayesian approaches successfully predicted BuChE inhibitors. The study proved the feasibility of a new method for predicting bioactivities of ligands and discovering novel lead compounds.
Jacobsen, Sonja; Patel, Pranav; Schmidt-Chanasit, Jonas; Leparc-Goffart, Isabelle; Teichmann, Anette; Zeller, Herve; Niedrig, Matthias
2016-03-01
Since the re-emergence of Chikungunya virus (CHIKV) in Reunion in 2005 and the recent outbreak in the Caribbean islands with an expansion to the Americas the CHIK diagnostic became very important. We evaluate the performance of laboratories regarding molecular and serological diagnostic of CHIK worldwide. A panel of 12 samples for molecular and 13 samples for serology were provided to 60 laboratories in 40 countries for evaluating the sensitivity and specificity of molecular and serology testing. The panel for molecular diagnostic testing was analysed by 56 laboratories returning 60 data sets of results whereas the 56 and 60 data sets were returned for IgG and IgM diagnostic from the participating laboratories. Twenty-three from 60 data sets performed optimal, 7 acceptable and 30 sets of results require improvement. From 50 data sets only one laboratory shows an optimal performance for IgM detection, followed by 9 data sets with acceptable and the rest need for improvement. From 46 IgG serology data sets 20 provide an optimal, 2 an acceptable and 24 require improvement performance. The evaluation of some of the diagnostic performances allows linking the quality of results to the in-house methods or commercial assays used. The external quality assurance for CHIK diagnostics provides a good overview on the laboratory performance regarding sensitivity and specificity for the molecular and serology diagnostic required for the quick and reliable analysis of suspected CHIK patients. Nearly half of the laboratories have to improve their diagnostic profile to achieve a better performance. Copyright © 2016 Z. Published by Elsevier B.V. All rights reserved.
Novel naïve Bayes classification models for predicting the carcinogenicity of chemicals.
Zhang, Hui; Cao, Zhi-Xing; Li, Meng; Li, Yu-Zhi; Peng, Cheng
2016-11-01
The carcinogenicity prediction has become a significant issue for the pharmaceutical industry. The purpose of this investigation was to develop a novel prediction model of carcinogenicity of chemicals by using a naïve Bayes classifier. The established model was validated by the internal 5-fold cross validation and external test set. The naïve Bayes classifier gave an average overall prediction accuracy of 90 ± 0.8% for the training set and 68 ± 1.9% for the external test set. Moreover, five simple molecular descriptors (e.g., AlogP, Molecular weight (M W ), No. of H donors, Apol and Wiener) considered as important for the carcinogenicity of chemicals were identified, and some substructures related to the carcinogenicity were achieved. Thus, we hope the established naïve Bayes prediction model could be applied to filter early-stage molecules for this potential carcinogenicity adverse effect; and the identified five simple molecular descriptors and substructures of carcinogens would give a better understanding of the carcinogenicity of chemicals, and further provide guidance for medicinal chemists in the design of new candidate drugs and lead optimization, ultimately reducing the attrition rate in later stages of drug development. Copyright © 2016 Elsevier Ltd. All rights reserved.
Tolerance measurements on internal- and external-hexagon implants.
Braian, Michael; De Bruyn, Hugo; Fransson, Håkan; Christersson, Cecilia; Wennerberg, Ann
2014-01-01
To measure the horizontal machining tolerances of the interface between internal- and external-hexagon implants and analogs with corresponding components after delivery from the manufacturer. These values may be a valuable tool for evaluating increasing misfit caused by fabrication, processing, and wear. Seven implants and seven analogs with external- and internal-hexagon connections (Biomet 3i) with corresponding prefabricated gold cylinders and gold screws, prefabricated cylindric plastic cylinders, and laboratory screws were studied. One set of components from the external and internal groups was measured manually and digitally. Measurements from the test subjects were compared with identical measurements from the virtual model to obtain threshold values. The virtual model was then used to obtain optimally oriented cuts. The horizontal machining tolerances for castable plastic abutments on external implants were 12 ± 89 μm, and for internal implants they were 86 ± 47 μm. Tolerance measurements on prefabricated gold abutments for external implants were 44 ± 9 μm, and for internal implants they were 58 ± 28 μm. The groups with metallic components showed the smallest tolerance at < 50 μm for the external group and < 90 μm for the internal group. The prefabricated plastic cylinder groups ranged from < 100 μm for external and < 130 μm for internal connection.
New public QSAR model for carcinogenicity
2010-01-01
Background One of the main goals of the new chemical regulation REACH (Registration, Evaluation and Authorization of Chemicals) is to fulfill the gaps in data concerned with properties of chemicals affecting the human health. (Q)SAR models are accepted as a suitable source of information. The EU funded CAESAR project aimed to develop models for prediction of 5 endpoints for regulatory purposes. Carcinogenicity is one of the endpoints under consideration. Results Models for prediction of carcinogenic potency according to specific requirements of Chemical regulation were developed. The dataset of 805 non-congeneric chemicals extracted from Carcinogenic Potency Database (CPDBAS) was used. Counter Propagation Artificial Neural Network (CP ANN) algorithm was implemented. In the article two alternative models for prediction carcinogenicity are described. The first model employed eight MDL descriptors (model A) and the second one twelve Dragon descriptors (model B). CAESAR's models have been assessed according to the OECD principles for the validation of QSAR. For the model validity we used a wide series of statistical checks. Models A and B yielded accuracy of training set (644 compounds) equal to 91% and 89% correspondingly; the accuracy of the test set (161 compounds) was 73% and 69%, while the specificity was 69% and 61%, respectively. Sensitivity in both cases was equal to 75%. The accuracy of the leave 20% out cross validation for the training set of models A and B was equal to 66% and 62% respectively. To verify if the models perform correctly on new compounds the external validation was carried out. The external test set was composed of 738 compounds. We obtained accuracy of external validation equal to 61.4% and 60.0%, sensitivity 64.0% and 61.8% and specificity equal to 58.9% and 58.4% respectively for models A and B. Conclusion Carcinogenicity is a particularly important endpoint and it is expected that QSAR models will not replace the human experts opinions and conventional methods. However, we believe that combination of several methods will provide useful support to the overall evaluation of carcinogenicity. In present paper models for classification of carcinogenic compounds using MDL and Dragon descriptors were developed. Models could be used to set priorities among chemicals for further testing. The models at the CAESAR site were implemented in java and are publicly accessible. PMID:20678182
Impact of a Pharmacist-Provided Spirometry Service on Access to Results in a Primary Care Setting.
Mueller, Lisa A; Valentino, Alexa Sevin; Clark, Aaron D; Li, Junan
2018-01-01
The primary objective of this study was to determine the effect of a pharmacist-provided spirometry service within a federally qualified health center on the percentage of spirometry referrals completed with results reviewed by the ordering provider. Secondary objectives evaluated differences between internal and external referrals, medication recommendations made by the pharmacist, and revenue brought in by the service. Chart reviews were completed to determine the referral completion rates between patients who received a spirometry referral before (December 2014-September 2015) and after (January 2016-October 2016) the implementation of the pharmacy-provided spirometry service. Chart reviews were also used to determine the number and completion rate among referrals for internal and external services in the postimplementation time frame. Chart reviews also assessed medication recommendations made by the pharmacist. The results demonstrate an increase in referral completion rate from 38.1% to 47.0% ( P = .08) between the pre- and postimplementation time frames. In the postimplementation time frame, there was a statistically significant difference in the percentage of referrals completed between in-house referrals and external referrals (70.0% and 40.9%, respectively, P = .0004). Comparing clinics with and without the spirometry service, there was a statistically significant difference in the total number of spirometry referrals (1.13% and 0.59%, respectively, P < .0001) and the percent of referrals completed (0.55% and 0.27%, respectively, P = .0002). The results suggest that offering spirometry within the primary care setting helps to increase the rate of completed spirometry tests with results available to the primary care provider. Additionally, the results show that there is an increased completion rate in patients who receive an internal spirometry referral, which may be due to reduced barriers in obtaining this testing. Overall, these results demonstrate that providing spirometry in the primary care setting helps to increase spirometry results obtained and could be beneficial in other primary care settings.
Humidification performance of two high-flow nasal cannula devices: a bench study.
Chikata, Yusuke; Izawa, Masayo; Okuda, Nao; Itagaki, Taiga; Nakataki, Emiko; Onodera, Mutsuo; Imanaka, Hideaki; Nishimura, Masaji
2014-08-01
Delivering heated and humidified medical gas at 20-60 L/min, high-flow nasal cannula (HFNC) creates low levels of PEEP and ameliorates respiratory mechanics. It has become a common therapy for patients with respiratory failure. However, independent measurement of heat and humidity during HFNC and comparison of HFNC devices are lacking. We evaluated 2 HFNC (Airvo 2 and Optiflow system) devices. Each HFNC was connected to simulated external nares using the manufacturer's standard circuit. The Airvo 2 outlet-chamber temperature was set at 37°C. The Optiflow system incorporated an O2/air blender and a heated humidifier, which was set at 40°C/3. For both systems, HFNC flow was tested at 20, 40, and 50 L/min. Simulating spontaneous breathing using a mechanical ventilator and TTL test lung, we tested tidal volumes (VT) of 300, 500, and 700 mL, and breathing frequencies of 10 and 20 breaths/min. The TTL was connected to the simulated external nares with a standard ventilator circuit. To prevent condensation, the circuit was placed in an incubator maintained at 37°C. Small, medium, and large nasal prongs were tested. Absolute humidity (AH) of inspired gas was measured at the simulated external nares. At 20, 40, and 50 L/min of flow, respective AH values for the Airvo 2 were 35.3 ± 2.0, 37.1 ± 2.2, and 37.6 ± 2.1 mg/L, and for the Optiflow system, 33.1 ± 1.5, 35.9 ± 1.7, and 36.2 ± 1.8 mg/L. AH was lower at 20 L/min of HFNC flow than at 40 and 50 L/min (P < .01). While AH remained constant at 40 and 50 L/min, at 20 L/min of HFNC flow, AH decreased as VT increased for both devices. During bench use of HFNC, AH increased with increasing HFNC flow. When the inspiratory flow of spontaneous breathing exceeded the HFNC flow, AH was influenced by VT. At all experimental settings, AH remained > 30 mg/L.
Quantitative structure-toxicity relationship (QSTR) studies on the organophosphate insecticides.
Can, Alper
2014-11-04
Organophosphate insecticides are the most commonly used pesticides in the world. In this study, quantitative structure-toxicity relationship (QSTR) models were derived for estimating the acute oral toxicity of organophosphate insecticides to male rats. The 20 chemicals of the training set and the seven compounds of the external testing set were described by means of using descriptors. Descriptors for lipophilicity, polarity and molecular geometry, as well as quantum chemical descriptors for energy were calculated. Model development to predict toxicity of organophosphate insecticides in different matrices was carried out using multiple linear regression. The model was validated internally and externally. In the present study, QSTR model was used for the first time to understand the inherent relationships between the organophosphate insecticide molecules and their toxicity behavior. Such studies provide mechanistic insight about structure-toxicity relationship and help in the design of less toxic insecticides. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Xu, Fang; Wallace, Robyn C.; Garvin, William; Greenlund, Kurt J.; Bartoli, William; Ford, Derek; Eke, Paul; Town, G. Machell
2016-01-01
Public health researchers have used a class of statistical methods to calculate prevalence estimates for small geographic areas with few direct observations. Many researchers have used Behavioral Risk Factor Surveillance System (BRFSS) data as a basis for their models. The aims of this study were to 1) describe a new BRFSS small area estimation (SAE) method and 2) investigate the internal and external validity of the BRFSS SAEs it produced. The BRFSS SAE method uses 4 data sets (the BRFSS, the American Community Survey Public Use Microdata Sample, Nielsen Claritas population totals, and the Missouri Census Geographic Equivalency File) to build a single weighted data set. Our findings indicate that internal and external validity tests were successful across many estimates. The BRFSS SAE method is one of several methods that can be used to produce reliable prevalence estimates in small geographic areas. PMID:27418213
Precision assessment of model-based RSA for a total knee prosthesis in a biplanar set-up.
Trozzi, C; Kaptein, B L; Garling, E H; Shelyakova, T; Russo, A; Bragonzoni, L; Martelli, S
2008-10-01
Model-based Roentgen Stereophotogrammetric Analysis (RSA) was recently developed for the measurement of prosthesis micromotion. Its main advantage is that markers do not need to be attached to the implants as traditional marker-based RSA requires. Model-based RSA has only been tested in uniplanar radiographic set-ups. A biplanar set-up would theoretically facilitate the pose estimation algorithm, since radiographic projections would show more different shape features of the implants than in uniplanar images. We tested the precision of model-based RSA and compared it with that of the traditional marker-based method in a biplanar set-up. Micromotions of both tibial and femoral components were measured with both the techniques from double examinations of patients participating in a clinical study. The results showed that in the biplanar set-up model-based RSA presents a homogeneous distribution of precision for all the translation directions, but an inhomogeneous error for rotations, especially internal-external rotation presented higher errors than rotations about the transverse and sagittal axes. Model-based RSA was less precise than the marker-based method, although the differences were not significant for the translations and rotations of the tibial component, with the exception of the internal-external rotations. For both prosthesis components the precisions of model-based RSA were below 0.2 mm for all the translations, and below 0.3 degrees for rotations about transverse and sagittal axes. These values are still acceptable for clinical studies aimed at evaluating total knee prosthesis micromotion. In a biplanar set-up model-based RSA is a valid alternative to traditional marker-based RSA where marking of the prosthesis is an enormous disadvantage.
Glavatskikh, Marta; Madzhidov, Timur; Solov'ev, Vitaly; Marcou, Gilles; Horvath, Dragos; Varnek, Alexandre
2016-12-01
In this work, we report QSPR modeling of the free energy ΔG of 1 : 1 hydrogen bond complexes of different H-bond acceptors and donors. The modeling was performed on a large and structurally diverse set of 3373 complexes featuring a single hydrogen bond, for which ΔG was measured at 298 K in CCl 4 . The models were prepared using Support Vector Machine and Multiple Linear Regression, with ISIDA fragment descriptors. The marked atoms strategy was applied at fragmentation stage, in order to capture the location of H-bond donor and acceptor centers. Different strategies of model validation have been suggested, including the targeted omission of individual H-bond acceptors and donors from the training set, in order to check whether the predictive ability of the model is not limited to the interpolation of H-bond strength between two already encountered partners. Successfully cross-validating individual models were combined into a consensus model, and challenged to predict external test sets of 629 and 12 complexes, in which donor and acceptor formed single and cooperative H-bonds, respectively. In all cases, SVM models outperform MLR. The SVM consensus model performs well both in 3-fold cross-validation (RMSE=1.50 kJ/mol), and on the external test sets containing complexes with single (RMSE=3.20 kJ/mol) and cooperative H-bonds (RMSE=1.63 kJ/mol). © 2016 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Tack, Véronique; Ligtenberg, Marjolijn J L; Tembuyser, Lien; Normanno, Nicola; Vander Borght, Sara; Han van Krieken, J; Dequeker, Elisabeth M C
2015-03-01
Regulations for the selection of patients with metastatic colorectal cancer for anti-EGFR treatment changed at the end of 2013. The set of mutations to be tested extended from KRAS codons 12 and 13 to KRAS and NRAS exons 2, 3, and 4. A European external quality assessment scheme monitored the performance of laboratories and evaluated the implementation of the new regulations. The 131 participating laboratories received 10 samples of formalin-fixed paraffin-embedded material, including RAS (exon 2, 3, 4) and BRAF mutations. Mock clinical data were provided for three cases. Using their routine methods, laboratories determined the genotypes and submitted three written reports. Assessors scored the results according to predefined evaluation criteria. Half of the participants (49.3%) had completely implemented the new test requirements (codons 12, 13, 59, 61, 117, and 146 of KRAS and NRAS), and 96 laboratories (73.3%) made no genotype mistakes. Correct nomenclature, according to the Human Genome Variation Society, was used by 82 laboratories (62.6%). Although regulations were effective for several months, many laboratories were not ready for full RAS testing in the context of anti-EGFR therapy. Nevertheless, in each participating country, there are laboratories that provide complete and correct testing. External quality assessments can be used to monitor implementation of new test regulations and to stimulate the laboratories to improve their testing procedures. Because the results of this program are available on the website of the European Society of Pathology, patients and clinicians can refer test samples to a reliable laboratory. ©AlphaMed Press.
Lee, Ya-Chen; Yu, Wan-Hui; Hsueh, I-Ping; Chen, Sheng-Shiung; Hsieh, Ching-Lin
2017-10-01
A lack of evidence on the test-retest reliability and responsiveness limits the utility of the BI-based Supplementary Scales (BI-SS) in both clinical and research settings. To examine the test-retest reliability and responsiveness of the BI-based Supplementary Scales (BI-SS) in patients with stroke. A repeated-assessments design (1 week apart) was used to examine the test-retest reliability of the BI-SS. For the responsiveness study, the participants were assessed with the BI-SS and BI (treated as an external criterion) at admission to and discharge from rehabilitation wards. Seven outpatient rehabilitation units and one inpatient rehabilitation unit. Outpatients with chronic stroke. Eighty-four outpatients with chronic stroke participated in the test-retest reliability study. Fifty-seven inpatients completed baseline and follow-up assessments in the responsiveness study. For the test-retest reliability study, the values of the intra-class correlation coefficient and the overall percentage of minimal detectable change for the Ability Scale and Self-perceived Difficulty Scale were 0.97, 12.8%, and 0.78, 35.8%, respectively. For the responsiveness study, the standardized effect size and standardized response mean (representing internal responsiveness) of the Ability Scale and Self-perceived Difficulty Scale were 1.17 and 1.56, and 0.78 and 0.89, respectively. Regarding external responsiveness, the change in score of the Ability Scale had significant and moderate association with that of the BI (r=0.61, P<0.001). The change in score of the Self-perceived Difficulty Scale had non-significant and weak association with that of the BI (r=0.23, P=0.080). The Ability Scale of the BI-SS has satisfactory test-retest reliability and sufficient responsiveness for patients with stroke. However, the Self-perceived Difficulty Scale of the BI-SS has substantial random measurement error and insufficient external responsiveness, which may affect its utility in clinical settings. The findings of this study provide empirical evidence of psychometric properties of the BI-SS for assessing ability and self-perceived difficulty of ADL in patients with stroke.
Analysis of heat-transfer measurements from 2 AEDC wind tunnels on the Shuttle external tank
NASA Technical Reports Server (NTRS)
Nutt, K. W.
1984-01-01
Previous aerodynamic heating tests have been conducted in the AEDC/VKF Supersonic Wind Tunnel (A) to aid in defining the design thermal environment for the space shuttle external tank. The quality of these data has been under discussion because of the effects of low tunnel enthalpy and slow model injection rates. Recently the AEDC/VKF Hypersonic Wind Tunnel (C) has been modified to provide a Mach 4 capability that has significantly higher tunnel enthalpy with more rapid model injection rates. Tests were conducted in Tunnel C at Mach 4 to obtain data on the external tank for comparison with Tunnel A results. Data were obtained on a 0.0175 scale model of the Space Shuttle Integrated Vehicle at Re/ft = 4 x 10 to the 6th power with the tunnel stagnation temperature varying from 740 to 1440 R. Model attitude varied from an angle of attack of -5 to 5 deg and an angle of sideslip of -3 to 3 deg. One set of data was obtained in Tunnel C at Re/ft = 6.9 x 10 to the 6th for comparison with flight data. Data comparisons between the two tunnels for numerous regions on the external tank are given.
Measurements by a Vector Network Analyzer at 325 to 508 GHz
NASA Technical Reports Server (NTRS)
Fung, King Man; Samoska, Lorene; Chattopadhyay, Goutam; Gaier, Todd; Kangaslahti, Pekka; Pukala, David; Lau, Yuenie; Oleson, Charles; Denning, Anthony
2008-01-01
Recent experiments were performed in which return loss and insertion loss of waveguide test assemblies in the frequency range from 325 to 508 GHz were measured by use of a swept-frequency two-port vector network analyzer (VNA) test set. The experiments were part of a continuing effort to develop means of characterizing passive and active electronic components and systems operating at ever increasing frequencies. The waveguide test assemblies comprised WR-2.2 end sections collinear with WR-3.3 middle sections. The test set, assembled from commercially available components, included a 50-GHz VNA scattering- parameter test set and external signal synthesizers, augmented with recently developed frequency extenders, and further augmented with attenuators and amplifiers as needed to adjust radiofrequency and intermediate-frequency power levels between the aforementioned components. The tests included line-reflect-line calibration procedures, using WR-2.2 waveguide shims as the "line" standards and waveguide flange short circuits as the "reflect" standards. Calibrated dynamic ranges somewhat greater than about 20 dB for return loss and 35 dB for insertion loss were achieved. The measurement data of the test assemblies were found to substantially agree with results of computational simulations.
APEX 3: a multi-purpose test platform for auditory psychophysical experiments.
Francart, Tom; van Wieringen, Astrid; Wouters, Jan
2008-07-30
APEX 3 is a software test platform for auditory behavioral experiments. It provides a generic means of setting up experiments without any programming. The supported output devices include sound cards and cochlear implants from Cochlear Corporation and Advanced Bionics Corporation. Many psychophysical procedures are provided and there is an interface to add custom procedures. Plug-in interfaces are provided for data filters and external controllers. APEX 3 is supported under Linux and Windows and is available free of charge.
ERIC Educational Resources Information Center
Bagamery, Bruce D.; Lasik, John J.; Nixon, Don R.
2005-01-01
Extending previous studies, the authors examined a larger set of variables to identify predictors of student performance on the Educational Testing Service Major Field Exam in Business, which has been shown to be an externally valid measure of student learning outcomes. Significant predictors include gender, whether students took the SAT, and…
Lin, Yihan; Mukhopadhyay, Swagoto; Meguid, Robert A; Kuwayama, David P
Interest in humanitarian surgery is high among surgical and obstetric residents. The Colorado Humanitarian Surgical Skills Workshop is an annual 2-day course exposing senior residents to surgical techniques essential in low- and middle-income countries but not traditionally taught in US residencies. We evaluated the course's ability to foster resident comfort, knowledge, and competence in these skills. The cohort of course participants was studied prospectively. Participants attended didactic sessions followed by skills sessions using cadavers. Sample areas of focus included general surgery (mesh-free hernia repair), orthopedics (powerless external fixation), and neurosurgery (powerless craniotomy). Before and after the course, participants answered a questionnaire assessing confidence with taught skills; took a knowledge-based test composed of multiple choice and open-ended questions; and participated in a manual skills test of tibial external fixation. The Center for Surgical Innovation, University of Colorado School of Medicine. A total of 12 residents (11 general surgical and 1 obstetric) from ten US institutions. After the course, participants perceived increased confidence in performing all 27 taught procedures and ability to practice in low- and middle-income countries. In knowledge-based testing, 10 of 12 residents demonstrated improvement on multiple choice questioning and 9 of 12 residents demonstrated improvement on open-ended questioning with structured scoring. In manual skills testing, all external fixator constructs demonstrated objective improvement on structured scoring and subjective improvement on stability assessment. For senior residents interested in humanitarian surgery, a combination of skills-focused teaching and manual practice led to self-perceived and objective improvement in relevant surgical knowledge and skills. The Colorado Humanitarian Surgical Skills Workshop represents an effective model for transmitting essential surgical principles and techniques of value in low-resource settings. Copyright © 2017 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
Karamouzian, Mohammad; Knight, Rod; Davis, Wendy M; Gilbert, Mark; Shoveller, Jean
2018-02-01
Background Online sexually transmissible infection (STI) testing is increasingly available and has shown promising results across different settings. However, evidence on how stigma associated with STI testing may be experienced by youth in the context of these online services is limited. A convenience sample of 71 youth (aged 15-24 years) both male and female was engaged through online and offline recruitment strategies in Vancouver, Canada. Through semistructured and exploratory interviews, participants were asked about their perceptions of stigma associated with STI testing in an online testing environment. Data were analysed using a thematic analysis approach. Youth came from a diverse set of sociodemographic backgrounds and most (n=46, 65%) had previously accessed STI testing in clinic-based settings. Participants' perceptions pointed to the benefits of online testing for reducing the external stigma despite the potential persistence of internalised stigma. Notions of hegemonic masculinity and emphasised femininity were also present in the participants' descriptions of the role of gender in accessing online STI testing. Online STI testing could potentially ameliorate the experiences of participants in regards to the stigma associated with STI testing; however, participants' internalised feelings of shame and stigma around testing for STI may continue to persist. Our findings underscore the need to revisit and re-evaluate existing STI testing services to provide less anxiety-inducing testing environments for youth.
Rational selection of training and test sets for the development of validated QSAR models
NASA Astrophysics Data System (ADS)
Golbraikh, Alexander; Shen, Min; Xiao, Zhiyan; Xiao, Yun-De; Lee, Kuo-Hsiung; Tropsha, Alexander
2003-02-01
Quantitative Structure-Activity Relationship (QSAR) models are used increasingly to screen chemical databases and/or virtual chemical libraries for potentially bioactive molecules. These developments emphasize the importance of rigorous model validation to ensure that the models have acceptable predictive power. Using k nearest neighbors ( kNN) variable selection QSAR method for the analysis of several datasets, we have demonstrated recently that the widely accepted leave-one-out (LOO) cross-validated R2 (q2) is an inadequate characteristic to assess the predictive ability of the models [Golbraikh, A., Tropsha, A. Beware of q2! J. Mol. Graphics Mod. 20, 269-276, (2002)]. Herein, we provide additional evidence that there exists no correlation between the values of q 2 for the training set and accuracy of prediction ( R 2) for the test set and argue that this observation is a general property of any QSAR model developed with LOO cross-validation. We suggest that external validation using rationally selected training and test sets provides a means to establish a reliable QSAR model. We propose several approaches to the division of experimental datasets into training and test sets and apply them in QSAR studies of 48 functionalized amino acid anticonvulsants and a series of 157 epipodophyllotoxin derivatives with antitumor activity. We formulate a set of general criteria for the evaluation of predictive power of QSAR models.
Arduino: a low-cost multipurpose lab equipment.
D'Ausilio, Alessandro
2012-06-01
Typical experiments in psychological and neurophysiological settings often require the accurate control of multiple input and output signals. These signals are often generated or recorded via computer software and/or external dedicated hardware. Dedicated hardware is usually very expensive and requires additional software to control its behavior. In the present article, I present some accuracy tests on a low-cost and open-source I/O board (Arduino family) that may be useful in many lab environments. One of the strengths of Arduinos is the possibility they afford to load the experimental script on the board's memory and let it run without interfacing with computers or external software, thus granting complete independence, portability, and accuracy. Furthermore, a large community has arisen around the Arduino idea and offers many hardware add-ons and hundreds of free scripts for different projects. Accuracy tests show that Arduino boards may be an inexpensive tool for many psychological and neurophysiological labs.
NASA Astrophysics Data System (ADS)
Zhu, Hui; Shan, Xuekang; Sun, Xiaohan
2017-10-01
A method for reconstructing the vibration waveform from the optical time-domain backscattering pulses in the distributed optical fiber sensing system (DOFSS) is proposed, which allows for extracting and recovering the external vibration signal from the tested pulses by analog signal processing, so that can obtain vibration location and waveform simultaneously. We establish the response model of DOFSS to the external vibration and analyze the effects of system parameters on the operational performance. The main parts of the DOFSS are optimized, including delay fiber length and wavelength, to improve the sensitivity of the system. The experimental system is set up and the vibration amplitudes and reconstructed waveforms are fit well with the original driving signal. The experimental results demonstrate that the performance of vibration waveform reconstruction is good with SNR of 15 dB whenever the external vibrations with different intensities and frequencies exert on the sensing fiber.
NASA Astrophysics Data System (ADS)
Chen, Wei-Jhen; Lee, Yue-Lin; Wu, Ti-Yuan; Chen, Tzu-Ching; Hsu, Chih-Hui; Lin, Ming-Tzer
2018-01-01
This study investigated the effects of electric current and external stress on electromigration of intermetallic compounds (IMC) between solder and copper substrate. Different samples were tested under three different sets of conditions: (1) thermal aging only, (2) thermal aging with electric current ,where resistivity changes were measured using four-point probe measurements, (3) thermal aging with electric current and external stress provided using a four-point bending apparatus. The micro-structural changes in the samples were observed. The results were closely examined; particularly the coupling effect of electric current and external stress to elucidate the electromigration mechanism, as well as the formation of IMC in the samples. For thermal-aging-only samples, the IMC growth mechanism was controlled by grain boundary diffusion. Meanwhile, for thermal aging and applied electric current samples, the IMC growth mechanism was dominated by volume diffusion and interface reaction. Lastly, the IMC growth mechanism in the electric current and external stress group was dominated by grain boundary diffusion with grain growth. The results reveal that the external stress/strain and electric current play a significant role in the electromigration of copper-tin IMC. The samples exposed to tensile stress have reduced electromigration, while those subjected under compressive stress have enhanced electromigration.
Johansson, Fredrik R.; Skillgate, Eva; Lapauw, Mattis L.; Clijmans, Dorien; Deneulin, Valentijn P.; Palmans, Tanneke; Engineer, Human Kinetic; Cools, Ann M.
2015-01-01
Context Shoulder strength assessment plays an important role in the clinical examination of the shoulder region. Eccentric strength measurements are of special importance in guiding the clinician in injury prevention or return-to-play decisions after injury. Objective To examine the absolute and relative reliability and validity of a standardized eccentric strength-measurement protocol for the glenohumeral external rotators. Design Descriptive laboratory study. Setting Testing environment at the Department of Rehabilitation Sciences and Physiotherapy of Ghent University, Belgium. Patients or Other Participants Twenty-five healthy participants (9 men and 16 women) without any history of shoulder pain were tested by 2 independent assessors using a handheld dynamometer (HHD) and underwent an isokinetic testing procedure. Intervention(s) The clinical protocol used an HHD, a DynaPort accelerometer to measure acceleration and angular velocity of testing 30°/s over 90° of range of motion, and a Biodex dynamometer to measure isokinetic activity. Main Outcome Measure(s) Three eccentric strength measurements: (1) tester 1 with the HHD, (2) tester 2 with the HHD, and (3) Biodex isokinetic strength measurement. Results The intratester reliability was excellent (0.879 and 0.858), whereas the intertester reliability was good, with an intraclass correlation coefficient between testers of 0.714. Pearson product moment correlation coefficients of 0.78 and 0.70 were noted between the HHD and the isokinetic data, showing good validity of this new procedure. Conclusions Standardized eccentric rotator cuff strength can be tested and measured in the clinical setting with good-to-excellent reliability and validity using an HHD. PMID:25974381
LOLAweb: a containerized web server for interactive genomic locus overlap enrichment analysis.
Nagraj, V P; Magee, Neal E; Sheffield, Nathan C
2018-06-06
The past few years have seen an explosion of interest in understanding the role of regulatory DNA. This interest has driven large-scale production of functional genomics data and analytical methods. One popular analysis is to test for enrichment of overlaps between a query set of genomic regions and a database of region sets. In this way, new genomic data can be easily connected to annotations from external data sources. Here, we present an interactive interface for enrichment analysis of genomic locus overlaps using a web server called LOLAweb. LOLAweb accepts a set of genomic ranges from the user and tests it for enrichment against a database of region sets. LOLAweb renders results in an R Shiny application to provide interactive visualization features, enabling users to filter, sort, and explore enrichment results dynamically. LOLAweb is built and deployed in a Linux container, making it scalable to many concurrent users on our servers and also enabling users to download and run LOLAweb locally.
Steppan, Martin; Kraus, Ludwig; Piontek, Daniela; Siciliano, Valeria
2013-01-01
Prevalence estimation of cannabis use is usually based on self-report data. Although there is evidence on the reliability of this data source, its cross-cultural validity is still a major concern. External objective criteria are needed for this purpose. In this study, cannabis-related search engine query data are used as an external criterion. Data on cannabis use were taken from the 2007 European School Survey Project on Alcohol and Other Drugs (ESPAD). Provincial data came from three Italian nation-wide studies using the same methodology (2006-2008; ESPAD-Italia). Information on cannabis-related search engine query data was based on Google search volume indices (GSI). (1) Reliability analysis was conducted for GSI. (2) Latent measurement models of "true" cannabis prevalence were tested using perceived availability, web-based cannabis searches and self-reported prevalence as indicators. (3) Structure models were set up to test the influences of response tendencies and geographical position (latitude, longitude). In order to test the stability of the models, analyses were conducted on country level (Europe, US) and on provincial level in Italy. Cannabis-related GSI were found to be highly reliable and constant over time. The overall measurement model was highly significant in both data sets. On country level, no significant effects of response bias indicators and geographical position on perceived availability, web-based cannabis searches and self-reported prevalence were found. On provincial level, latitude had a significant positive effect on availability indicating that perceived availability of cannabis in northern Italy was higher than expected from the other indicators. Although GSI showed weaker associations with cannabis use than perceived availability, the findings underline the external validity and usefulness of search engine query data as external criteria. The findings suggest an acceptable relative comparability of national (provincial) prevalence estimates of cannabis use that are based on a common survey methodology. Search engine query data are a too weak indicator to base prevalence estimations on this source only, but in combination with other sources (waste water analysis, sales of cigarette paper) they may provide satisfactory estimates. Copyright © 2012. Published by Elsevier B.V.
Sunderland, Matthew; Slade, Tim; Krueger, Robert F; Markon, Kristian E; Patrick, Christopher J; Kramer, Mark D
2017-07-01
The development of the Externalizing Spectrum Inventory (ESI) was motivated by the need to comprehensively assess the interrelated nature of externalizing psychopathology and personality using an empirically driven framework. The ESI measures 23 theoretically distinct yet related unidimensional facets of externalizing, which are structured under 3 superordinate factors representing general externalizing, callous aggression, and substance abuse. One limitation of the ESI is its length at 415 items. To facilitate the use of the ESI in busy clinical and research settings, the current study sought to examine the efficiency and accuracy of a computerized adaptive version of the ESI. Data were collected over 3 waves and totaled 1,787 participants recruited from undergraduate psychology courses as well as male and female state prisons. A series of 6 algorithms with different termination rules were simulated to determine the efficiency and accuracy of each test under 3 different assumed distributions. Scores generated using an optimal adaptive algorithm evidenced high correlations (r > .9) with scores generated using the full ESI, brief ESI item-based factor scales, and the 23 facet scales. The adaptive algorithms for each facet administered a combined average of 115 items, a 72% decrease in comparison to the full ESI. Similarly, scores on the item-based factor scales of the ESI-brief form (57 items) were generated using on average of 17 items, a 70% decrease. The current study successfully demonstrates that an adaptive algorithm can generate similar scores for the ESI and the 3 item-based factor scales using a fraction of the total item pool. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
NASA Technical Reports Server (NTRS)
Zoughi, R.; Kharkovsky, S.; Hepburn, F. L.
2005-01-01
The utility of microwave and millimeter wave nondestructive testing and evaluation (NDT&E) methods, for testing the Space Shuttle's external he1 tank spray on foam insulation (SOFI) and the acreage heat tiles has been investigated during the past two years. Millimeter wave NDE techniques are capable of producing internal images of SOFI. This paper presents the results of testing several diverse panels with embedded voids and debonds at millimeter wave frequencies. Additionally, the results of testing a set of heat tiles are also presented. Finally, the attributes of these methods as well as the advantageous features associated with these systems are also provided.
Static investigation of several yaw vectoring concepts on nonaxisymmetric nozzles
NASA Technical Reports Server (NTRS)
Mason, M. L.; Berrier, B. L.
1985-01-01
A test has been conducted in the static test facility of the Langley 16-Foot Transonic Tunnel to determine the flow-turning capability and the effects on nozzle internal performance of several yaw vectoring concepts. Nonaxisymmetric convergent-divergent nozzles with throat areas simulating dry and afterburning power settings and single expansion ramp nozzles with a throat area simulating a dry power setting were modified for yaw thrust vectoring. Forward-thrust and pitch-vectored nozzle configurations were tested with each yaw vectoring concept. Four basic yaw vectoring concepts were investigated on the nonaxisymmetric convergent-divergent nozzles: (1) translating sidewall; (2) downstream (of throat) flaps; (3) upstream (of throat) port/flap; and (4) powered rudder. Selected combinations of the rudder with downstream flaps or upstream port/flap were also tested. A single yaw vectoring concept, post-exit flaps, was investigated on the single expansion ramp nozzles. All testing was conducted at static (no external flow) conditions and nozzle pressure ratios varied from 2.0 up to 10.0.
Testing Method for External Cladding Systems - Incerc Romania
NASA Astrophysics Data System (ADS)
Simion, A.; Dragne, H.
2017-06-01
This research presents a new testing method in a natural scale for external cladding systems tested on buildings with minimum than 3 floors [1]. The testing method is unique in Romania and it is similar about many fire testing current methods from European Union states. Also, presents the fire propagation and the effect of fire smoke on the building façade composed of thermal insulation. Laboratory of testing and research for building fire safety from National Institute INCERC Bucharest, provides a test method for determining the fire performance characteristics of non-loadbearing external cladding systems and external wall insulation systems when applied to the face of a building and exposed to an external fire under controlled conditions [2]. The fire exposure is representative of an external fire source or a fully-developed (post-flashover) fire in a room, venting through an opening such as a window aperture that exposes the cladding to the effects of external flames, or an external fire source. On the future, fire tests will be experimented for answer demande a number of high-profile fires where the external facade of tall buildings provided a route for vertical fire spread.
Modeling Liver-Related Adverse Effects of Drugs Using kNN QSAR Method
Rodgers, Amie D.; Zhu, Hao; Fourches, Dennis; Rusyn, Ivan; Tropsha, Alexander
2010-01-01
Adverse effects of drugs (AEDs) continue to be a major cause of drug withdrawals both in development and post-marketing. While liver-related AEDs are a major concern for drug safety, there are few in silico models for predicting human liver toxicity for drug candidates. We have applied the Quantitative Structure Activity Relationship (QSAR) approach to model liver AEDs. In this study, we aimed to construct a QSAR model capable of binary classification (active vs. inactive) of drugs for liver AEDs based on chemical structure. To build QSAR models, we have employed an FDA spontaneous reporting database of human liver AEDs (elevations in activity of serum liver enzymes), which contains data on approximately 500 approved drugs. Approximately 200 compounds with wide clinical data coverage, structural similarity and balanced (40/60) active/inactive ratio were selected for modeling and divided into multiple training/test and external validation sets. QSAR models were developed using the k nearest neighbor method and validated using external datasets. Models with high sensitivity (>73%) and specificity (>94%) for prediction of liver AEDs in external validation sets were developed. To test applicability of the models, three chemical databases (World Drug Index, Prestwick Chemical Library, and Biowisdom Liver Intelligence Module) were screened in silico and the validity of predictions was determined, where possible, by comparing model-based classification with assertions in publicly available literature. Validated QSAR models of liver AEDs based on the data from the FDA spontaneous reporting system can be employed as sensitive and specific predictors of AEDs in pre-clinical screening of drug candidates for potential hepatotoxicity in humans. PMID:20192250
Wireless powering for a self-propelled and steerable endoscopic capsule for stomach inspection.
Carta, R; Tortora, G; Thoné, J; Lenaerts, B; Valdastri, P; Menciassi, A; Dario, P; Puers, R
2009-12-15
This paper describes the integration of an active locomotion module in a wirelessly powered endoscopic capsule. The device is a submersible capsule optimized to operate in a fluid environment in a liquid-distended stomach. A 3D inductive link is used to supply up to 400mW to the embedded electronics and a set of 4 radio-controlled motor propellers. The design takes advantage of a ferrite-core in the receiving coil-set. This approach significantly improves the coupling with the external field source with respect to earlier work by the group. It doubles the power that can be received with a coreless coil-set under identical external conditions. The upper limit of the received power was achieved complying with the strict regulations for safe exposure of biological tissue to variable magnetic fields. The wireless transferred power was proven to be sufficient to achieve the speed of 7cm/s in any directions. An optimized locomotion strategy was defined which limits the power consumption by running only 2 motors at a time. A user interface and a joystick controller allow to fully drive the capsule in an intuitive manner. The device functionalities were successfully tested in a dry and a wet environment in a laboratory set-up.
Dry selection and wet evaluation for the rational discovery of new anthelmintics
NASA Astrophysics Data System (ADS)
Marrero-Ponce, Yovani; Castañeda, Yeniel González; Vivas-Reyes, Ricardo; Vergara, Fredy Máximo; Arán, Vicente J.; Castillo-Garit, Juan A.; Pérez-Giménez, Facundo; Torrens, Francisco; Le-Thi-Thu, Huong; Pham-The, Hai; Montenegro, Yolanda Vera; Ibarra-Velarde, Froylán
2017-09-01
Helminths infections remain a major problem in medical and public health. In this report, atom-based 2D bilinear indices, a TOMOCOMD-CARDD (QuBiLs-MAS module) molecular descriptor family and linear discriminant analysis (LDA) were used to find models that differentiate among anthelmintic and non-anthelmintic compounds. Two classification models obtained by using non-stochastic and stochastic 2D bilinear indices, classified correctly 86.64% and 84.66%, respectively, in the training set. Equation 1(2) correctly classified 141(135) out of 165 [85.45%(81.82%)] compounds in external validation set. Another LDA models were performed in order to get the most likely mechanism of action of anthelmintics. The model shows an accuracy of 86.84% in the training set and 94.44% in the external prediction set. Finally, we carry out an experiment to predict the biological profile of our 'in-house' collections of indole, indazole, quinoxaline and cinnoline derivatives (∼200 compounds). Subsequently, we selected a group of nine of the theoretically most active structures. Then, these chemicals were tested in an in vitro assay and one good candidate (VA5-5c) as fasciolicide compound (100% of reduction at concentrations of 50 and 10 mg/L) was discovered.
An investigation of the heat induced during ultrasonic post removal.
Ettrich, Christopher A; Labossière, Paul E; Pitts, David L; Johnson, James D
2007-10-01
The purpose of this study was to investigate the potential for temperature increase along the external root surface during ultrasonic post removal in a simulated clinical environment. Thirty-seven extracted teeth were decoronated, instrumented, and then obturated with gutta-percha and sealer. Post spaces were prepared, followed by cementation of stainless steel posts. A simulated clinical environment was created by using a polymethylmethacrylate sheet with holes custom fitted for the extracted teeth and then suspended over a heated water bath. Two thermocouples were attached at 6 and 12 mm from the top of the post along the external root surface. Teeth were divided into 3 test groups, no coolant, air-cooled, and water-cooled. Temperature changes were recorded by using a Vishay 5000 Strain Smart system. Results demonstrated that a significant difference existed in the average heat rates between the upper and lower thermocouples for no coolant and water-cooled groups at the medium setting and the air-cooled group at the high setting. The average heat rates were significantly different between the 2 thermocouples for all 3 groups when comparing the 2 ultrasonic power settings. Results indicated that the average heat rate was less for the water-cooled group when using a medium power setting.
Lightning protection for shuttle propulsion elements
NASA Technical Reports Server (NTRS)
Goodloe, Carolyn C.; Giudici, Robert J.
1991-01-01
The results of lightning protection analyses and tests are weighed against the present set of waivers to the NASA lightning protection specification. The significant analyses and tests are contrasted with the release of a new and more realistic lightning protection specification, in September 1990, that resulted in an inordinate number of waivers. A variety of lightning protection analyses and tests of the Shuttle propulsion elements, the Solid Rocket Booster, the External Tank, and the Space Shuttle Main Engine, were conducted. These tests range from the sensitivity of solid propellant during shipping to penetration of cryogenic tanks during flight. The Shuttle propulsion elements have the capability to survive certain levels of lightning strikes at certain times during transportation, launch site operations, and flight. Changes are being evaluated that may improve the odds of withstanding a major lightning strike. The Solid Rocket Booster is the most likely propulsion element to survive if systems tunnel bond straps are improved. Wiring improvements were already incorporated and major protection tests were conducted. The External Tank remains vulnerable to burn-through penetration of its skin. Proposed design improvements include the use of a composite nose cone and conductive or laminated thermal protection system coatings.
Data base for the prediction of inlet external drag
NASA Technical Reports Server (NTRS)
Mcmillan, O. J.; Perkins, E. W.; Perkins, S. C., Jr.
1980-01-01
Results are presented from a study to define and evaluate the data base for predicting an airframe/propulsion system interference effect shown to be of considerable importance, inlet external drag. The study is focused on supersonic tactical aircraft with highly integrated jet propulsion systems, although some information is included for supersonic strategic aircraft and for transport aircraft designed for high subsonic or low supersonic cruise. The data base for inlet external drag is considered to consist of the theoretical and empirical prediction methods as well as the experimental data identified in an extensive literature search. The state of the art in the subsonic and transonic speed regimes is evaluated. The experimental data base is organized and presented in a series of tables in which the test article, the quantities measured and the ranges of test conditions covered are described for each set of data; in this way, the breadth of coverage and gaps in the existing experimental data are evident. Prediction methods are categorized by method of solution, type of inlet and speed range to which they apply, major features are given, and their accuracy is assessed by means of comparison to experimental data.
C-C1-04: Building a Health Services Information Technology Research Environment
Gehrum, David W; Jones, JB; Romania, Gregory J; Young, David L; Lerch, Virginia R; Bruce, Christa A; Donkochik, Diane; Stewart, Walter F
2010-01-01
Background: The electronic health record (EHR) has opened a new era for health services research (HSR) where information technology (IT) is used to re-engineer care processes. While the EHR provides one means of advancing novel solutions, a promising strategy is to develop tools (e.g., online questionnaires, visual display tools, decision support) distinct from, but which interact with, the EHR. Development of such software tools outside the EHR offers an advantage in flexibility, sophistication, and ultimately in portability to other settings. However, institutional IT departments have an imperative to protect patient data and to standardize IT processes to ensure system-level security and support traditional business needs. Such imperatives usually present formidable process barriers to testing novel software solutions. We describe how, in collaboration with our IT department, we are creating an environment and a process that allows for routine and rapid testing of novel software solutions. Methods: We convened a working group consisting of IT and research personnel with expertise in information security, database design/management, web design, EHR programming, and health services research. The working group was tasked with developing a research IT environment to accomplish two objectives: maintain network/ data security and regulatory compliance; allow researchers working with external vendors to rapidly prototype and, in a clinical setting, test web-based tools. Results: Two parallel solutions, one focused on hardware, the second on oversight and management, were developed. First, we concluded that three separate, staged development environments were required to allow external vendor access for testing software and for transitioning software to be used in a clinic. In parallel, the extant oversight process for approving/managing access to internal/external personnel had to be altered to reflect the scope and scale of discrete research projects, as opposed to an enterpriselevel approach to IT management. Conclusions: Innovation in health services software development requires a flexible, scalable IT environment adapted to the unique objectives of a HSR software development model. In our experience, implementing the hardware solution is less challenging than the cultural change required to implement such a model and the modifications to administrative and oversight processes to sustain an environment for rapid product development and testing.
The quality of care in occupational therapy: an assessment of selected Michigan hospitals.
Kirchman, M M
1979-07-01
In this study, a methodology was developed and tested for assessing the quality of care in occupational therapy between educational and noneducational clinical settings, as measured by process and outcome. An instrument was constructed for an external audit of the hospital record. Standards drafted by the investigator were established as normative by a panel of experts for use in judging the programs. Hospital records of 84 patients with residual hemiparesis or hemiplegia in three noneducational settings and of 100 patients with similar diagnoses in two educational clinical settings from selected Michigan facilities were chosen by proportionate stratified random sampling. The process study showed that occupational therapy was of significantly higher quality in the educational settings. The outcome study did not show significant differences between types of settings. Implications for education and practice are discussed.
Hamadache, Mabrouk; Benkortbi, Othmane; Hanini, Salah; Amrane, Abdeltif; Khaouane, Latifa; Si Moussa, Cherif
2016-02-13
Quantitative Structure Activity Relationship (QSAR) models are expected to play an important role in the risk assessment of chemicals on humans and the environment. In this study, we developed a validated QSAR model to predict acute oral toxicity of 329 pesticides to rats because a few QSAR models have been devoted to predict the Lethal Dose 50 (LD50) of pesticides on rats. This QSAR model is based on 17 molecular descriptors, and is robust, externally predictive and characterized by a good applicability domain. The best results were obtained with a 17/9/1 Artificial Neural Network model trained with the Quasi Newton back propagation (BFGS) algorithm. The prediction accuracy for the external validation set was estimated by the Q(2)ext and the root mean square error (RMS) which are equal to 0.948 and 0.201, respectively. 98.6% of external validation set is correctly predicted and the present model proved to be superior to models previously published. Accordingly, the model developed in this study provides excellent predictions and can be used to predict the acute oral toxicity of pesticides, particularly for those that have not been tested as well as new pesticides. Copyright © 2015 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Williamson, Mark S.; Son Wonmin; Heaney, Libby
Recently, it was demonstrated by Son et al., Phys. Rev. Lett. 102, 110404 (2009), that a separable bipartite continuous-variable quantum system can violate the Clauser-Horne-Shimony-Holt (CHSH) inequality via operationally local transformations. Operationally local transformations are parametrized only by local variables; however, in order to allow violation of the CHSH inequality, a maximally entangled ancilla was necessary. The use of the entangled ancilla in this scheme caused the state under test to become dependent on the measurement choice one uses to calculate the CHSH inequality, thus violating one of the assumptions used in deriving a Bell inequality, namely, the free willmore » or statistical independence assumption. The novelty in this scheme however is that the measurement settings can be external free parameters. In this paper, we generalize these operationally local transformations for multipartite Bell inequalities (with dichotomic observables) and provide necessary and sufficient conditions for violation within this scheme. Namely, a violation of a multipartite Bell inequality in this setting is contingent on whether an ancillary system admits any realistic local hidden variable model (i.e., whether the ancilla violates the given Bell inequality). These results indicate that violation of a Bell inequality performed on a system does not necessarily imply that the system is nonlocal. In fact, the system under test may be completely classical. However, nonlocality must have resided somewhere, this may have been in the environment, the physical variables used to manipulate the system or the detectors themselves provided the measurement settings are external free variables.« less
Lui, P Priscilla
2018-02-19
The acculturation gap-distress theory postulates that parent-offspring acculturation mismatch precipitates greater intergenerational conflict in immigrant families, which in turn increases the risk for psychological problems among offspring. Whereas cross-sectional studies have shown support for these theory-informed relations, comparatively little is known about whether acculturation mismatch negatively affects psychological functioning, or whether offspring's psychological problems precipitate greater perceived acculturation mismatch via intergenerational cultural conflict. Furthermore, more research is needed to investigate how acculturation and family conflict affect Asian Americans transitioning into college and emerging adulthood. Across two measurement occasions, two cohorts of Asian American first-year college students (N = 555, Mage = 17.99, 56.0% women) completed survey questionnaires assessing their perception of parent-offspring acculturation discrepancies, acculturation-related intergenerational conflict, and internalizing and externalizing symptoms. For both sets of psychological functioning, gender invariant structural equation models testing the bidirectional relations demonstrated adequate fit for the data. In the case of externalizing symptoms, acculturation mismatch marginally significantly predicted subsequent intergenerational conflict, but acculturation mismatch did not predict externalizing symptoms via intergenerational cultural conflict. By contrast, offspring's internalizing and externalizing symptoms respectively predicted greater self-reported intergenerational cultural conflict, which in turn predicted perceived parent-offspring acculturation mismatch over time. These indirect relations suggested that both internalizing and externalizing symptoms indirectly contributed to greater acculturation mismatch through the presence of intergenerational cultural conflict, but data did not support the acculturation gap-distress theory. Theoretical and clinical implications as they pertain to Asian American emerging adults are discussed. (PsycINFO Database Record (c) 2018 APA, all rights reserved).
Dick, Danielle M.; Latendresse, Shawn J.; Lansford, Jennifer E.; Budde, John P.; Goate, Alison; Dodge, Kenneth A.; Pettit, Gregory S.; Bates, John E.
2009-01-01
Context As we identify genes involved in psychiatric disorders, the next step will be to study how the risk associated with susceptibility genes manifests across development and in conjunction with the environment. We describe analyses aimed at characterizing the pathway of risk associated with GABRA2, a gene previously associated with adult alcohol dependence, in a community sample of children followed longitudinally from childhood through young adulthood. Objective To test for an association between GABRA2 and trajectories of externalizing behavior from adolescence to young adulthood and for moderation of genetic effects by parental monitoring. Design Data were analyzed from the Child Development Project, with yearly assessments conducted since that time. A saliva sample was collected for DNA at the 2006 follow-up, with a 93% response rate in the target sample. Growth mixture modeling was conducted using Mplus to identify trajectories of externalizing behavior and to test for effects of GABRA2 sequence variants and parental monitoring. Setting Nashville and Knoxville, Tennessee, and Bloomington, Indiana. Participants A community-based sample of families enrolled at 3 sites as children entered kindergarten in 1987 and 1988. Analyses for the white subset of the sample (n=378) are reported here. Main Outcome Measures Parental monitoring measured at 11 years of age; Child Behavior Checklist youth reports of externalizing behavior at ages 12, 14, 15, 16, 17, 19, 20, 21, and 22 years. Results Two classes of externalizing behavior emerged: a stable high externalizing class and a moderate decreasing externalizing behavior class. The GABRA2 gene was associated with class membership, with subjects who showed persistent elevated trajectories of externalizing behavior more likely to carry the genotype previously associated with increased risk of adult alcohol dependence. A significant interaction with parental monitoring emerged; the association of GABRA2 with externalizing trajectories diminished with high levels of parental monitoring. Conclusions These analyses underscore the importance of studying genetic effects across development and of identifying environmental factors that moderate risk. PMID:19487630
Hetley, Richard; Dosher, Barbara Anne; Lu, Zhong-Lin
2014-01-01
Attention precues improve the performance of perceptual tasks in many but not all circumstances. These spatial attention effects may depend upon display set size or workload, and have been variously attributed to external noise filtering, stimulus enhancement, contrast gain, or response gain, or to uncertainty or other decision effects. In this study, we document systematically different effects of spatial attention in low- and high-precision judgments, with and without external noise, and in different set sizes in order to contribute to the development of a taxonomy of spatial attention. An elaborated perceptual template model (ePTM) provides an integrated account of a complex set of effects of spatial attention with just two attention factors: a set-size dependent exclusion or filtering of external noise and a narrowing of the perceptual template to focus on the signal stimulus. These results are related to the previous literature by classifying the judgment precision and presence of external noise masks in those experiments, suggesting a taxonomy of spatially cued attention in discrimination accuracy. PMID:24939234
Hetley, Richard; Dosher, Barbara Anne; Lu, Zhong-Lin
2014-11-01
Attention precues improve the performance of perceptual tasks in many but not all circumstances. These spatial attention effects may depend upon display set size or workload, and have been variously attributed to external noise filtering, stimulus enhancement, contrast gain, or response gain, or to uncertainty or other decision effects. In this study, we document systematically different effects of spatial attention in low- and high-precision judgments, with and without external noise, and in different set sizes in order to contribute to the development of a taxonomy of spatial attention. An elaborated perceptual template model (ePTM) provides an integrated account of a complex set of effects of spatial attention with just two attention factors: a set-size dependent exclusion or filtering of external noise and a narrowing of the perceptual template to focus on the signal stimulus. These results are related to the previous literature by classifying the judgment precision and presence of external noise masks in those experiments, suggesting a taxonomy of spatially cued attention in discrimination accuracy.
Insulin compatibility with polymer materials used in external pump infusion systems.
Melberg, S G; Havelund, S; Villumsen, J; Brange, J
1988-04-01
In a study designed to mimic actual user conditions for external insulin pump infusion, the insulin quality after passage through the infusion set was assessed by various analytical methods, including high performance liquid chromatography. The two infusion sets tested consisted of, firstly, a polyvinylchloride/rubber syringe and a polyvinylchloride catheter sterilized by gamma irradiation and, secondly, a polyethylene/polypropylene syringe connected to a polyethylene catheter and sterilized by ethylene oxide. The insulin solution delivered through the PVC infusion set showed a reduction of preservative to less than 30% of the initial content and increased formation of chemical transformation products of insulin varying from twice the reference level during the first day to more than three times on the third day. By contrast, the polyethylene/polypropylene infusion system showed only a minor decrease in preservative content and no increase in chemical transformation. These effects were observed irrespective of the brand of insulin and were not affected by increase of the zinc content of the insulin solution. Investigation of the influence of the sterilization methods performed on polyvinylchloride and polyethylene catheters revealed that gamma irradiated polyvinylchloride catheters were markedly harmful to the insulin solution, whereas ethylene oxide sterilization did not influence the chemical stability of insulin.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cho, Daniel D; Wernicke, A Gabriella; Nori, Dattatreyudu
Purpose/Objective(s): The aim of this study is to build the estimator of toxicity using artificial neural network (ANN) for head and neck cancer patients Materials/Methods: An ANN can combine variables into a predictive model during training and considered all possible correlations of variables. We constructed an ANN based on the data from 73 patients with advanced H and N cancer treated with external beam radiotherapy and/or chemotherapy at our institution. For the toxicity estimator we defined input data including age, sex, site, stage, pathology, status of chemo, technique of external beam radiation therapy (EBRT), length of treatment, dose of EBRT,more » status of post operation, length of follow-up, the status of local recurrences and distant metastasis. These data were digitized based on the significance and fed to the ANN as input nodes. We used 20 hidden nodes (for the 13 input nodes) to take care of the correlations of input nodes. For training ANN, we divided data into three subsets such as training set, validation set and test set. Finally, we built the estimator for the toxicity from ANN output. Results: We used 13 input variables including the status of local recurrences and distant metastasis and 20 hidden nodes for correlations. 59 patients for training set, 7 patients for validation set and 7 patients for test set and fed the inputs to Matlab neural network fitting tool. We trained the data within 15% of errors of outcome. In the end we have the toxicity estimation with 74% of accuracy. Conclusion: We proved in principle that ANN can be a very useful tool for predicting the RT outcomes for high risk H and N patients. Currently we are improving the results using cross validation.« less
Code of Federal Regulations, 2014 CFR
2014-01-01
..., set the clock time to 3:23 and use the average power approach described in Section 5, Paragraph 5.3.2... circulates air internally or externally to the cooking product for a finite period of time after the end of... persist for an indefinite time. An indicator that only shows the user that the product is in the off...
Liu, Shu-Shen; Qin, Li-Tang; Liu, Hai-Ling; Yin, Da-Qiang
2008-02-01
Molecular electronegativity distance vector (MEDV) derived directly from the molecular topological structures was used to describe the structures of 122 nonionic organic compounds (NOCs) and a quantitative relationship between the MEDV descriptors and the bioconcentration factors (BCF) of NOCs in fish was developed using the variable selection and modeling based on prediction (VSMP). It was found that some main structural factors influencing the BCFs of NOCs are the substructures expressed by four atomic types of nos. 2, 3, 5, and 13, i.e., atom groups -CH(2)- or =CH-, -CH< or =C<, -NH(2), and -Cl or -Br where the former two groups exist in the molecular skeleton of NOC and the latter three groups are related closely to the substituting groups on a benzene ring. The best 5-variable model, with the correlation coefficient (r(2)) of 0.9500 and the leave-one-out cross-validation correlation coefficient (q(2)) of 0.9428, was built by multiple linear regressions, which shows a good estimation ability and stability. A predictive power for the external samples was tested by the model from the training set of 80 NOCs and the predictive correlation coefficient (u(2)) for the 42 external samples in the test set was 0.9028.
Lü, Xiao-jing; Li, Ning; Weng, Chun-sheng
2016-03-01
Compared with traditional sampling-based sensing method, absorption spectroscopy technology is well suitable for detonation flow diagnostics, since it can provide with us fast response, nonintrusive, sensitive solution for situ measurements of multiple flow-field parameters. The temperature and concentration test results are the average values along the laser path with traditional absorption spectroscopy technology, while the boundary of detonation flow external field is unknown and it changes all the time during the detonation engine works, traditional absorption spectroscopy technology is no longer suitable for detonation diagnostics. The trend of line strength with temperature varies with different absorption lines. By increasing the number of absorption lines in the test path, more information of the non-uniform flow field can be obtained. In this paper, based on multispectral absorption technology, the reconstructed model of detonation flow external field distribution was established according to the simulation results of space-time conservation element and solution element method, and a diagnostic method of detonation flow external field was given. The model deviation and calculation error of the least squares method adopted were studied by simulation, and the maximum concentration and temperature calculation error was 20.1% and 3.2%, respectively. Four absorption lines of H2O were chosen and detonation flow was scanned at the same time. The detonation external flow testing system was set up for the valveless gas-liquid continuous pulse detonation engine with the diameter of 80 mm. Through scanning H2O absorption lines with a high frequency of 10 kHz, the on-line detection of detonation external flow was realized by direct absorption method combined with time-division multiplexing technology, and the reconstruction of dynamic temperature distribution was realized as well for the first time, both verifying the feasibility of the test method. The test results show that both of the temperature and H2O concentration rose with the arrival of detonation wave. With the increase of the vertical distance between the detonation tube nozzle and the laser path, the time of temperature and concentration coming to the peak delayed, and the temperature variation trend tended to slow down. At 20 cm from detonation tube nozzle, the maximum temperature hit 1 329 K and the maximum H2O concentration of 0.19 occurred at 4 ms after ignition. The research can provide with us the support for expanding the detonation test field with absorption spectroscopy technology, and can also help to promote the detonation mechanism research and to enhance the level of detonation engine control technology.
NASA Technical Reports Server (NTRS)
Akyuzlu, K. M.; Jones, S.; Meredith, T.
1993-01-01
Self pressurization by propellant boiloff is experimentally studied as an alternate pressurization concept for the Space Shuttle external tank (ET). The experimental setup used in the study is an open flow system which is composed of a variable area test tank and a recovery tank. The vacuum jacketed test tank is geometrically similar to the external LOx tank for the Space Shuttle. It is equipped with instrumentation to measure the temperature and pressure histories within the liquid and vapor, and viewports to accommodate visual observations and Laser-Doppler Anemometry measurements of fluid velocities. A set of experiments were conducted using liquid Nitrogen to determine the temperature stratification in the liquid and vapor, and pressure histories of the vapor during sudden and continuous depressurization for various different boundary and initial conditions. The study also includes the development and calibration of a computer model to simulate the experiments. This model is a one-dimensional, multi-node type which assumes the liquid and the vapor to be under non-equilibrium conditions during the depressurization. It has been tested for a limited number of cases. The preliminary results indicate that the accuracy of the simulations is determined by the accuracy of the heat transfer coefficients for the vapor and the liquid at the interface which are taken to be the calibration parameters in the present model.
Hobbs, Savannah; King, Christian
2018-05-09
To examine the associations of food insecurity with children's cognitive and behavioral outcomes using quantile regression. Secondary analysis of the Fragile Families and Child Wellbeing Study dataset. A total of 2,046 children aged 5 years. Child behavioral outcomes were measured using externalizing (aggressive) and internalizing (emotional) behavior problems. Child cognitive outcomes were measured using the Peabody Vocabulary test and the Woodcock-Johnson letter-word identification test. Food insecurity was measured using the US Department of Agriculture's Food Security Module. Unconditional quantile regressions were employed. Statistical significance was set at P ≤ .05. Negative associations between food insecurity and child behavior problems (externalizing and internalizing) were largest for children with the most behavior problems. For Peabody Vocabulary scores, the negative association with food insecurity was statistically significant only for children in the top half of the distribution (≥50th percentile). The analysis found mixed evidence of an association between food insecurity and the Woodcock-Johnson letter-word identification test. These associations were similar for boys and girls. Because children's cognitive skills and behavioral problems have long-lasting implications and effects later in life, reducing the risk of food insecurity might particularly benefit children with greater externalizing and internalizing behavior problems. Copyright © 2018 Society for Nutrition Education and Behavior. Published by Elsevier Inc. All rights reserved.
Salinas La Casta, Maria; Flores Pardo, Emilio; Uris Selles, Joaquín
2009-01-01
to propose a set of indicators as a management tool for a clinical laboratory, by using the balanced scorecard internal business processes perspective. indicators proposed are obtained from different sources; external proficiency testing of the Valencia Community Government, by means of internal surveys and laboratory information system registers. One year testing process proportion indicators results are showed. internal management indicators are proposed (process, appropriateness and proficiency testing). The process indicators results show gradual improvement since its establishment. after one years of using a conceptually solid Balanced Scorecard Internal business processes perspective indicators, the obtained results validate the usefulness as a laboratory management tool.
Chen, Guangchao; Li, Xuehua; Chen, Jingwen; Zhang, Ya-Nan; Peijnenburg, Willie J G M
2014-12-01
Biodegradation is the principal environmental dissipation process of chemicals. As such, it is a dominant factor determining the persistence and fate of organic chemicals in the environment, and is therefore of critical importance to chemical management and regulation. In the present study, the authors developed in silico methods assessing biodegradability based on a large heterogeneous set of 825 organic compounds, using the techniques of the C4.5 decision tree, the functional inner regression tree, and logistic regression. External validation was subsequently carried out by 2 independent test sets of 777 and 27 chemicals. As a result, the functional inner regression tree exhibited the best predictability with predictive accuracies of 81.5% and 81.0%, respectively, on the training set (825 chemicals) and test set I (777 chemicals). Performance of the developed models on the 2 test sets was subsequently compared with that of the Estimation Program Interface (EPI) Suite Biowin 5 and Biowin 6 models, which also showed a better predictability of the functional inner regression tree model. The model built in the present study exhibits a reasonable predictability compared with existing models while possessing a transparent algorithm. Interpretation of the mechanisms of biodegradation was also carried out based on the models developed. © 2014 SETAC.
Lin, Guigao; Zhang, Kuo; Zhang, Dong; Han, Yanxi; Xie, Jiehong; Li, Jinming
2017-03-01
The emergence of Zika virus demands accurate laboratory diagnostics. Nucleic acid testing is currently the definitive method for diagnosis of Zika infection. In 2016, an external quality assurance (EQA) for assessing the quality of molecular testing of Zika virus was carried out in China. A single armored RNA encapsulating a 4942-nucleotides (nt) long specific RNA sequence of Zika virus was prepared and used as positive samples. A pre-tested EQA panel, consisting of 4 negative and 6 positive samples with different concentrations of armored RNA, was distributed to 38 laboratories that perform molecular detection of Zika virus. A total of 39 data sets (1 laboratory used two test kits in parallel), produced by using commercial (n=38) or laboratory developed (n=1) quantitative reverse-transcriptase PCR (qRT-PCR) kits, were received. Of these, 35 (89.7%) had correct results for all 10 samples, and 4 (10.3%) reported at least 1 error (11 in total). The testing errors were all false-negatives, highlighting the need of improvements in detecting sensitivity. The EQA reveals that the majority of participating laboratories are proficient in molecular testing of Zika virus. Copyright © 2017 Elsevier B.V. All rights reserved.
ERIC Educational Resources Information Center
Squires, Garry; Caddick, Katie
2012-01-01
There has been a growing interest in the use of cognitive behavioural therapy (CBT) in school settings by educational psychologists in England. This small-scale study set out to explore the effectiveness of a school-based, eight-session CBT intervention for 12-13-year-old children with externalizing behavioural difficulties. Twelve pupils were…
NASA Astrophysics Data System (ADS)
Gaede, Stewart; Carnes, Gregory; Yu, Edward; Van Dyk, Jake; Battista, Jerry; Lee, Ting-Yim
2009-01-01
The purpose of this paper is to describe a non-invasive method to monitor the motion of internal organs affected by respiration without using external markers or spirometry, to test the correlation with external markers, and to calculate any time shift between the datasets. Ten lung cancer patients were CT scanned with a GE LightSpeed Plus 4-Slice CT scanner operating in a ciné mode. We retrospectively reconstructed the raw CT data to obtain consecutive 0.5 s reconstructions at 0.1 s intervals to increase image sampling. We defined regions of interest containing tissue interfaces, including tumour/lung interfaces that move due to breathing on multiple axial slices and measured the mean CT number versus respiratory phase. Tumour motion was directly correlated with external marker motion, acquired simultaneously, using the sample coefficient of determination, r2. Only three of the ten patients showed correlation higher than r2 = 0.80 between tumour motion and external marker position. However, after taking into account time shifts (ranging between 0 s and 0.4 s) between the two data sets, all ten patients showed correlation better than r2 = 0.8. This non-invasive method for monitoring the motion of internal organs is an effective tool that can assess the use of external markers for 4D-CT imaging and respiratory-gated radiotherapy on a patient-specific basis.
Gaede, Stewart; Carnes, Gregory; Yu, Edward; Van Dyk, Jake; Battista, Jerry; Lee, Ting-Yim
2009-01-21
The purpose of this paper is to describe a non-invasive method to monitor the motion of internal organs affected by respiration without using external markers or spirometry, to test the correlation with external markers, and to calculate any time shift between the datasets. Ten lung cancer patients were CT scanned with a GE LightSpeed Plus 4-Slice CT scanner operating in a ciné mode. We retrospectively reconstructed the raw CT data to obtain consecutive 0.5 s reconstructions at 0.1 s intervals to increase image sampling. We defined regions of interest containing tissue interfaces, including tumour/lung interfaces that move due to breathing on multiple axial slices and measured the mean CT number versus respiratory phase. Tumour motion was directly correlated with external marker motion, acquired simultaneously, using the sample coefficient of determination, r(2). Only three of the ten patients showed correlation higher than r(2) = 0.80 between tumour motion and external marker position. However, after taking into account time shifts (ranging between 0 s and 0.4 s) between the two data sets, all ten patients showed correlation better than r(2) = 0.8. This non-invasive method for monitoring the motion of internal organs is an effective tool that can assess the use of external markers for 4D-CT imaging and respiratory-gated radiotherapy on a patient-specific basis.
Slavov, Svetoslav H; Wilkes, Jon G; Buzatu, Dan A; Kruhlak, Naomi L; Willard, James M; Hanig, Joseph P; Beger, Richard D
2014-12-01
Modified 3D-SDAR fingerprints combining (13)C and (15)N NMR chemical shifts augmented with inter-atomic distances were used to model the potential of chemicals to induce phospholipidosis (PLD). A curated dataset of 328 compounds (some of which were cationic amphiphilic drugs) was used to generate 3D-QSDAR models based on tessellations of the 3D-SDAR space with grids of different density. Composite PLS models averaging the aggregated predictions from 100 fully randomized individual models were generated. On each of the 100 runs, the activities of an external blind test set comprised of 294 proprietary chemicals were predicted and averaged to provide composite estimates of their PLD-inducing potentials (PLD+ if PLD is observed, otherwise PLD-). The best performing 3D-QSDAR model utilized a grid with a density of 8ppm×8ppm in the C-C region, 8ppm×20ppm in the C-N region and 20ppm×20ppm in the N-N region. The classification predictive performance parameters of this model evaluated on the basis of the external test set were as follows: accuracy=0.70, sensitivity=0.73 and specificity=0.66. A projection of the most frequently occurring bins on the standard coordinate space suggested a toxicophore composed of an aromatic ring with a centroid 3.5-7.5Å distant from an amino-group. The presence of a second aromatic ring separated by a 4-5Å spacer from the first ring and at a distance of between 5.5Å and 7Å from the amino-group was also associated with a PLD+ effect. These models provide comparable predictive performance to previously reported models for PLD with the added benefit of being based entirely on non-confidential, publicly available training data and with good predictive performance when tested in a rigorous, external validation exercise. Published by Elsevier Ltd.
Development and pilot test of a process to identify research needs from a systematic review.
Saldanha, Ian J; Wilson, Lisa M; Bennett, Wendy L; Nicholson, Wanda K; Robinson, Karen A
2013-05-01
To ensure appropriate allocation of research funds, we need methods for identifying high-priority research needs. We developed and pilot tested a process to identify needs for primary clinical research using a systematic review in gestational diabetes mellitus. We conducted eight steps: abstract research gaps from a systematic review using the Population, Intervention, Comparison, Outcomes, and Settings (PICOS) framework; solicit feedback from the review authors; translate gaps into researchable questions using the PICOS framework; solicit feedback from multidisciplinary stakeholders at our institution; establish consensus among multidisciplinary external stakeholders on the importance of the research questions using the Delphi method; prioritize outcomes; develop conceptual models to highlight research needs; and evaluate the process. We identified 19 research questions. During the Delphi method, external stakeholders established consensus for 16 of these 19 questions (15 with "high" and 1 with "medium" clinical benefit/importance). We pilot tested an eight-step process to identify clinically important research needs. Before wider application of this process, it should be tested using systematic reviews of other diseases. Further evaluation should include assessment of the usefulness of the research needs generated using this process for primary researchers and funders. Copyright © 2013 Elsevier Inc. All rights reserved.
Watts, Christopher; Murphy, Jessica; Barnes-Burroughs, Kathryn
2003-06-01
At a physiological level, the act of singing involves control and coordination of several systems involved in the production of sound, including respiration, phonation, resonance, and afferent systems used to monitor production. The ability to produce a melodious singing voice (eg, in tune with accurate pitch) is dependent on control over these motor and sensory systems. To test this position, trained singers and untrained subjects with and without expressed singing talent were asked to match pitches of target pure tones. The ability to match pitch reflected the ability to accurately integrate sensory perception with motor planning and execution. Pitch-matching accuracy was measured at the onset of phonation (prephonatory set) before external feedback could be utilized to adjust the voiced source, during phonation when external auditory feedback could be utilized, and during phonation when external auditory feedback was masked. Results revealed trained singers and untrained subjects with singing talent were no different in their pitch-matching abilities when measured before or after external feedback could be utilized. The untrained subjects with singing talent were also significantly more accurate than the trained singers when external auditory feedback was masked. Both groups were significantly more accurate than the untrained subjects without singing talent.
Risk factors associated with exertional medial tibial pain: a 12 month prospective clinical study.
Burne, S G; Khan, K M; Boudville, P B; Mallet, R J; Newman, P M; Steinman, L J; Thornton, E
2004-08-01
To investigate in a military setting the potential role of intrinsic biomechanical and anthropometric risk factors for, and the incidence of, exertional medial tibial pain (EMTP). A prospective clinical outcome study in a cohort of 122 men and 36 women at the Australian Defence Force Academy. Each cadet underwent measurements of seven intrinsic variables: hip range of motion, leg length discrepancy, lean calf girth, maximum ankle dorsiflexion range, foot type, rear foot alignment, and tibial alignment. Test-retest reliability was undertaken on each variable. A physician recorded any cadet presenting with diagnostic criteria of EMTP. Records were analysed at 12 months for EMTP presentation and for military fitness test results. 23 cadets (12 men, 11 women) met the criteria for EMTP after 12 months, with a cross gender (F/M) odds ratio of 3.1. In men, both internal and external range of hip motion was greater in those with EMTP: left internal (12 degrees, p = 0.000), right internal (8 degrees, p = 0.014), left external (8 degrees, p = 0.042), right external (9 degrees, p = 0.026). Lean calf girth was lower by 4.2% for the right leg (p = 0.040) but by only 2.9% for the left leg (p = 0.141). No intrinsic risk factor was associated with EMTP in women. EMTP was the major cause for non-completion of the run component of the ADFA fitness test in both men and women. Greater internal and external hip range of motion and lower lean calf girth were associated with EMTP in male military cadets. Women had high rates of injury, although no intrinsic factor was identified. Reasons for this sex difference need to be identified.
What Is an Automated External Defibrillator?
ANSWERS by heart Treatments + Tests What Is an Automated External Defibrillator? An automated external defibrillator (AED) is a lightweight, portable device ... ANSWERS by heart Treatments + Tests What Is an Automated External Defibrillator? detect a rhythm that should be ...
49 CFR 192.471 - External corrosion control: Test leads.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 3 2012-10-01 2012-10-01 false External corrosion control: Test leads. 192.471... Control § 192.471 External corrosion control: Test leads. (a) Each test lead wire must be connected to the pipeline so as to remain mechanically secure and electrically conductive. (b) Each test lead wire must be...
49 CFR 192.471 - External corrosion control: Test leads.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 3 2013-10-01 2013-10-01 false External corrosion control: Test leads. 192.471... Control § 192.471 External corrosion control: Test leads. (a) Each test lead wire must be connected to the pipeline so as to remain mechanically secure and electrically conductive. (b) Each test lead wire must be...
49 CFR 192.471 - External corrosion control: Test leads.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 3 2014-10-01 2014-10-01 false External corrosion control: Test leads. 192.471... Control § 192.471 External corrosion control: Test leads. (a) Each test lead wire must be connected to the pipeline so as to remain mechanically secure and electrically conductive. (b) Each test lead wire must be...
Integrated Decision Strategies for Skin Sensitization Hazard
Strickland, Judy; Zang, Qingda; Kleinstreuer, Nicole; Paris, Michael; Lehmann, David M.; Choksi, Neepa; Matheson, Joanna; Jacobs, Abigail; Lowit, Anna; Allen, David; Casey, Warren
2016-01-01
One of the top priorities of ICCVAM is the identification and evaluation of non-animal alternatives for skin sensitization testing. Although skin sensitization is a complex process, the key biological events of the process have been well characterized in an adverse outcome pathway (AOP) proposed by OECD. Accordingly, ICCVAM is working to develop integrated decision strategies based on the AOP using in vitro, in chemico, and in silico information. Data were compiled for 120 substances tested in the murine local lymph node assay (LLNA), direct peptide reactivity assay (DPRA), human cell line activation test (h-CLAT), and KeratinoSens assay. Data for six physicochemical properties that may affect skin penetration were also collected, and skin sensitization read-across predictions were performed using OECD QSAR Toolbox. All data were combined into a variety of potential integrated decision strategies to predict LLNA outcomes using a training set of 94 substances and an external test set of 26 substances. Fifty-four models were built using multiple combinations of machine learning approaches and predictor variables. The seven models with the highest accuracy (89–96% for the test set and 96–99% for the training set) for predicting LLNA outcomes used a support vector machine (SVM) approach with different combinations of predictor variables. The performance statistics of the SVM models were higher than any of the non-animal tests alone and higher than simple test battery approaches using these methods. These data suggest that computational approaches are promising tools to effectively integrate data sources to identify potential skin sensitizers without animal testing. PMID:26851134
A miniature microcontroller curve tracing circuit for space flight testing transistors.
Prokop, N; Greer, L; Krasowski, M; Flatico, J; Spina, D
2015-02-01
This paper describes a novel miniature microcontroller based curve tracing circuit, which was designed to monitor the environmental effects on Silicon Carbide Junction Field Effect Transistor (SiC JFET) device performance, while exposed to the low earth orbit environment onboard the International Space Station (ISS) as a resident experiment on the 7th Materials on the International Space Station Experiment (MISSE7). Specifically, the microcontroller circuit was designed to operate autonomously and was flown on the external structure of the ISS for over a year. This curve tracing circuit is capable of measuring current vs. voltage (I-V) characteristics of transistors and diodes. The circuit is current limited for low current devices and is specifically designed to test high temperature, high drain-to-source resistance SiC JFETs. The results of each I-V data set are transmitted serially to an external telemetered communication interface. This paper discusses the circuit architecture, its design, and presents example results.
The effect of the long head of the biceps on glenohumeral kinematics.
Youm, Thomas; ElAttrache, Neal S; Tibone, James E; McGarry, Michelle H; Lee, Thay Q
2009-01-01
The long head of the biceps has been described as a stabilizing force in the setting of glenohumeral instability. However, data are lacking on the effect of loading the long head of the biceps on glenohumeral kinematics. Six cadaveric shoulders were tested for glenohumeral rotational range of motion and translation using a custom shoulder testing system and the Microscribe 3DLX (Immersion, San Jose, CA). The path of glenohumeral articulation (PGA) was measured by calculating the humeral head center with respect to the glenoid articular surface at maximal internal rotation, 30 degrees, 60 degrees, 90 degrees, and maximal external rotation. Significant decreases in glenohumeral rotational range of motion and translation were found with 22-N biceps loading vs the unloaded group. With respect to the PGA, the humeral rotation center was shifted posterior with biceps loading at maximal internal rotation, 30 degrees, and 60 degrees of external rotation. Loading the long head of the biceps significantly affects glenohumeral rotational range of motion, translations, and kinematics.
The Italian pilot external quality assessment program for cystic fibrosis sweat test.
Salvatore, Marco; Floridia, Giovanna; Amato, Annalisa; Censi, Federica; Carta, Claudio; de Stefano, Maria Chiara; Ferrari, Gianluca; Tosto, Fabrizio; Capoluongo, Ettore; Caruso, Ubaldo; Castaldo, Giuseppe; Cirilli, Natalia; Corbetta, Carlo; Padoan, Rita; Raia, Valeria; Taruscio, Domenica
2016-05-01
Sweat chloride test is the gold standard test for cystic fibrosis (CF) diagnosis. In 2014 the Istituto Superiore di Sanità established the Italian pilot external quality assessment program for CF sweat test (IEQA-ST). Ten laboratories, included among the 33 Italian CF Referral Centers, were selected and enrolled on the basis of their attitude to perform sweat test (ST) analysis by using methods recommended by the Italian Guidelines. They received three different sweat-like samples (normal, borderline and pathologic chloride concentration), with mock clinical indications, for analysis according to routine procedures. Assessment, performed by a panel of experts, covered analytical performance, interpretation and reporting of results; categories of "poor" and "satisfactory" performance were not defined. All data were managed through a web utility. The program identified important areas of interest and, in some case, of concern. It is important to underline that results are referred to a small proportion, i.e. about 30%, of Italian laboratories performing CF ST in the context of the Referral Centers. Data collected highlight the importance of participation in EQA programs as it may improve laboratory/clinical performance; our study represents a model for the setting up of a large-scale EQA scheme for ST. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Random forest models to predict aqueous solubility.
Palmer, David S; O'Boyle, Noel M; Glen, Robert C; Mitchell, John B O
2007-01-01
Random Forest regression (RF), Partial-Least-Squares (PLS) regression, Support Vector Machines (SVM), and Artificial Neural Networks (ANN) were used to develop QSPR models for the prediction of aqueous solubility, based on experimental data for 988 organic molecules. The Random Forest regression model predicted aqueous solubility more accurately than those created by PLS, SVM, and ANN and offered methods for automatic descriptor selection, an assessment of descriptor importance, and an in-parallel measure of predictive ability, all of which serve to recommend its use. The prediction of log molar solubility for an external test set of 330 molecules that are solid at 25 degrees C gave an r2 = 0.89 and RMSE = 0.69 log S units. For a standard data set selected from the literature, the model performed well with respect to other documented methods. Finally, the diversity of the training and test sets are compared to the chemical space occupied by molecules in the MDL drug data report, on the basis of molecular descriptors selected by the regression analysis.
Bartlett, John M S; Ibrahim, Merdol; Jasani, Bharat; Morgan, John M; Ellis, Ian; Kay, Elaine; Magee, Hilary; Barnett, Sarah; Miller, Keith
2007-07-01
Trastuzumab provides clinical benefit for advanced and early breast cancer patients whose tumours over-express or have gene amplification of the HER2 oncogene. The UK National External Quality Assessment Scheme (NEQAS) for immunohistochemical testing was established to assess and improve the quality of HER2 immunohistochemical testing. However, until recently, no provision was available for HER2 fluorescence in situ hybridisation (FISH) testing. A pilot scheme was set up to review the performance of FISH testing in clinical diagnostic laboratories. FISH was performed in 6 reference and 31 participating laboratories using a cell line panel with known HER2 status. Using results from reference laboratories as a criterion for acceptable performance, 60% of all results returned by participants were appropriate and 78% either appropriate or acceptable. However, 22.4% of results returned were deemed inappropriate, including 13 cases (4.2%) where a misdiagnosis would have been made had these been clinical specimens. The results of three consecutive runs show that both reference laboratories and a proportion of routine clinical diagnostic (about 25%) centres can consistently achieve acceptable quality control of HER2 testing. Data from a significant proportion of participating laboratories show that further steps are required, including those taken via review of performance under schemes such as NEQAS, to improve quality of HER2 testing by FISH in the "real world".
Dückers, Michel L A; Wagner, Cordula; Groenewegen, Peter P
2008-08-11
In quality improvement collaboratives (QICs) teams of practitioners from different health care organizations are brought together to systematically improve an aspect of patient care. Teams take part in a series of meetings to learn about relevant best practices, quality methods and change ideas, and share experiences in making changes in their own local setting. The purpose of this study was to develop an instrument for measuring team organization, external change agent support and support from the team's home institution in a Dutch national improvement and dissemination programme for hospitals based on several QICs. The exploratory methodological design included two phases: a) content development and assessment, resulting in an instrument with 15 items, and b) field testing (N = 165). Internal consistency reliability was tested via Cronbach's alpha coefficient. Principal component analyses were used to identify underlying constructs. Tests of scaling assumptions according to the multi trait/multi-item matrix, were used to confirm the component structure. Three components were revealed, explaining 65% of the variability. The components were labelled 'organizational support', 'team organization' and 'external change agent support'. One item not meeting item-scale criteria was removed. This resulted in a 14 item instrument. Scale reliability ranged from 0.77 to 0.91. Internal item consistency and divergent validity were satisfactory. On the whole, the instrument appears to be a promising tool for assessing team organization and internal and external support during QIC implementation. The psychometric properties were good and warrant application of the instrument for the evaluation of the national programme and similar improvement programmes.
ERIC Educational Resources Information Center
Valanides, Nicos; Efthymiou, Irene; Angeli, Charoula
2013-01-01
Fifty-six third-year kindergarten student teachers (KTS) were presented with an experimental setting for investigating shadow phenomena. Prior to performing any specific experiment, KTS were asked to externalize their ideas about shadow phenomena corresponding to different configurations of the experimental setting through the use of drawings…
Moisture content and gas sampling device
NASA Technical Reports Server (NTRS)
Krieg, H. C., Jr. (Inventor)
1985-01-01
An apparatus is described for measuring minute quantities of moisture and other contaminants within sealed enclosures such as electronic assemblies which may be subject to large external atmospheric pressure variations. An array of vacuum quality valves is arranged to permit cleansing of the test apparatus of residual atmospheric components from a vacuum source. This purging operation evacuates a gas sample bottle, which is then connected by valve settings to provide the drive for withdrawing a gas sample from the sealed enclosure under test into the sample bottle through a colometric detector tube (Drager tube) which indicates moisture content. The sample bottle may be disconnected and its contents (drawn from the test enclosure) separately subjected to mass spectrograph analysis.
Verma, Rajeshwar P; Matthews, Edwin J
2015-03-01
Evaluation of potential chemical-induced eye injury through irritation and corrosion is required to ensure occupational and consumer safety for industrial, household and cosmetic ingredient chemicals. The historical method for evaluating eye irritant and corrosion potential of chemicals is the rabbit Draize test. However, the Draize test is controversial and its use is diminishing - the EU 7th Amendment to the Cosmetic Directive (76/768/EEC) and recast Regulation now bans marketing of new cosmetics having animal testing of their ingredients and requires non-animal alternative tests for safety assessments. Thus, in silico and/or in vitro tests are advocated. QSAR models for eye irritation have been reported for several small (congeneric) data sets; however, large global models have not been described. This report describes FDA/CFSAN's development of 21 ANN c-QSAR models (QSAR-21) to predict eye irritation using the ADMET Predictor program and a diverse training data set of 2928 chemicals. The 21 models had external (20% test set) and internal validation and average training/verification/test set statistics were: 88/88/85(%) sensitivity and 82/82/82(%) specificity, respectively. The new method utilized multiple artificial neural network (ANN) molecular descriptor selection functionalities to maximize the applicability domain of the battery. The eye irritation models will be used to provide information to fill the critical data gaps for the safety assessment of cosmetic ingredient chemicals. Copyright © 2014 Elsevier Inc. All rights reserved.
Pakarinen, Harri; Flinkkilä, Tapio; Ohtonen, Pasi; Hyvönen, Pekka; Lakovaara, Martti; Leppilahti, Juhana; Ristiniemi, Jukka
2011-11-16
This study was designed to assess the sensitivity, specificity, and interobserver reliability of the hook test and the stress test for the intraoperative diagnosis of instability of the distal tibiofibular joint following fixation of ankle fractures resulting from supination-external rotation forces. We conducted a prospective study of 140 patients with an unstable unilateral ankle fracture resulting from a supination-external rotation mechanism (Lauge-Hansen SE). After internal fixation of the malleolar fracture, a hook test and an external rotation stress test under fluoroscopy were performed independently by the lead surgeon and assisting surgeon, followed by a standardized 7.5-Nm external rotation stress test of each ankle under fluoroscopy. A positive stress test result was defined as a side-to-side difference of >2 mm in the tibiotalar or the tibiofibular clear space on mortise radiographs. The sensitivity and specificity of each test were calculated with use of the standardized 7.5-Nm external rotation stress test as a reference. Twenty-four (17%) of the 140 patients had a positive standardized 7.5-Nm external rotation stress test after internal fixation of the malleolar fracture. The hook test had a sensitivity of 0.25 (95% confidence interval, 0.12 to 0.45) and a specificity of 0.98 (95% confidence interval, 0.94 to 1.0) for the detection of the same instabilities. The external rotation stress test had a sensitivity of 0.58 (95% confidence interval, 0.39 to 0.76) and a specificity of 0.96 (95% confidence interval, 0.90 to 0.98). Both tests had excellent interobserver reliability, with 99% agreement for the hook test and 98% for the stress test. Interobserver agreement for the hook test and the clinical stress test was excellent, but the sensitivity of these tests was insufficient to adequately detect instability of the syndesmosis intraoperatively.
Dual mode fuel injector with one piece needle valve member
Lawrence, Keith E.; Hinrichsen, Michael H.; Buckman, Colby
2005-01-18
A fuel injector includes a homogenous charge nozzle outlet set and a conventional nozzle outlet set controlled respectively by inner and outer needle value members. The homogenous charged nozzle outlet set is defined by an outer needle value member that is moveably positioned in an injector body, which defines the conventional nozzle outlet set. The inner needle valve member is positioned in the outer needle valve member. The outer needle valve member is a piece component that includes at least one external guide surface, an external value surface and an internal valve seat.
RF assisted switching in magnetic Josephson junctions
NASA Astrophysics Data System (ADS)
Caruso, R.; Massarotti, D.; Bolginov, V. V.; Ben Hamida, A.; Karelina, L. N.; Miano, A.; Vernik, I. V.; Tafuri, F.; Ryazanov, V. V.; Mukhanov, O. A.; Pepe, G. P.
2018-04-01
We test the effect of an external RF field on the switching processes of magnetic Josephson junctions (MJJs) suitable for the realization of fast, scalable cryogenic memories compatible with Single Flux Quantum logic. We show that the combined application of microwaves and magnetic field pulses can improve the performances of the device, increasing the separation between the critical current levels corresponding to logical "0" and "1." The enhancement of the current level separation can be as high as 80% using an optimal set of parameters. We demonstrate that external RF fields can be used as an additional tool to manipulate the memory states, and we expect that this approach may lead to the development of new methods of selecting MJJs and manipulating their states in memory arrays for various applications.
49 CFR 192.471 - External corrosion control: Test leads.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 3 2010-10-01 2010-10-01 false External corrosion control: Test leads. 192.471... TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Requirements for Corrosion Control § 192.471 External corrosion control: Test leads. (a) Each test lead wire must be connected to the...
49 CFR 192.471 - External corrosion control: Test leads.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 3 2011-10-01 2011-10-01 false External corrosion control: Test leads. 192.471... TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Requirements for Corrosion Control § 192.471 External corrosion control: Test leads. (a) Each test lead wire must be connected to the...
Moral identity as moral ideal self: links to adolescent outcomes.
Hardy, Sam A; Walker, Lawrence J; Olsen, Joseph A; Woodbury, Ryan D; Hickman, Jacob R
2014-01-01
The purposes of this study were to conceptualize moral identity as moral ideal self, to develop a measure of this construct, to test for age and gender differences, to examine links between moral ideal self and adolescent outcomes, and to assess purpose and social responsibility as mediators of the relations between moral ideal self and outcomes. Data came from a local school sample (Data Set 1: N = 510 adolescents; 10-18 years of age) and a national online sample (Data Set 2: N = 383 adolescents; 15-18 years of age) of adolescents and their parents. All outcome measures were parent-report (Data Set 1: altruism, moral personality, aggression, and cheating; Data Set 2: environmentalism, school engagement, internalizing, and externalizing), whereas other variables were adolescent-report. The 20-item Moral Ideal Self Scale showed good reliability, factor structure, and validity. Structural equation models demonstrated that, even after accounting for moral identity internalization, in Data Set 1 moral ideal self positively predicted altruism and moral personality and negatively predicted aggression, whereas in Data Set 2 moral ideal self positively predicted environmentalism and negatively predicted internalizing and externalizing symptoms. Further, purpose and social responsibility mediated most relations between moral ideal self and the outcomes in Data Set 2. Moral ideal self was unrelated to age but differentially predicted some outcomes across age. Girls had higher levels of moral ideal self than boys, although moral identity did not differentially predict outcomes between genders. Thus, moral ideal self is a salient element of moral identity and may play a role in morally relevant adolescent outcomes. PsycINFO Database Record (c) 2014 APA, all rights reserved.
NASA Astrophysics Data System (ADS)
Bergeron, Charles; Labelle, Hubert; Ronsky, Janet; Zernicke, Ronald
2005-04-01
Spinal curvature progression in scoliosis patients is monitored from X-rays, and this serial exposure to harmful radiation increases the incidence of developing cancer. With the aim of reducing the invasiveness of follow-up, this study seeks to relate the three-dimensional external surface to the internal geometry, having assumed that that the physiological links between these are sufficiently regular across patients. A database was used of 194 quasi-simultaneous acquisitions of two X-rays and a 3D laser scan of the entire trunk. Data was processed to sets of datapoints representing the trunk surface and spinal curve. Functional data analyses were performed using generalized Fourier series using a Haar basis and functional minimum noise fractions. The resulting coefficients became inputs and outputs, respectively, to an array of support vector regression (SVR) machines. SVR parameters were set based on theoretical results, and cross-validation increased confidence in the system's performance. Predicted lateral and frontal views of the spinal curve from the back surface demonstrated average L2-errors of 6.13 and 4.38 millimetres, respectively, across the test set; these compared favourably with measurement error in data. This constitutes a first robust prediction of the 3D spinal curve from external data using learning techniques.
Lin, Guigao; Zhang, Kuo; Han, Yanxi; Xie, Jiehong; Li, Jinming
2018-02-01
Due to the significant risk of developing Stevens-Johnson syndrome (SJS) and toxic epidermal necrolysis (TEN), the use of carbamazepine is not recommended in patients carrying the human leukocyte antigen B (HLA-B) *15:02 allele. In an effort to guarantee reliable community-based HLA-B*15:02 testing throughout China, a HLA-B*15:02 genotyping external quality assessment (EQA) program was set up. In 2016, 10 genomic DNA samples with known HLA-B*15:02 allele status were sent to 37 laboratories from 16 provinces with a request for routine HLA-B*15:02 screening. The samples were validated using Sanger sequencing by a reference laboratory. Both genotyping results and clinical written reports were evaluated. Thirty-six of the participating laboratories correctly identified the HLA-B*15:02 allele status for all EQA samples. However, one lab failed to identify any positive challenges. The overall analytical sensitivity was 97.3% (180/185 challenges; 95% confidence interval: 93.8%-99.1%) and the analytic specificity was 100% (185/185; 95% confidence interval: 98.0%-100%). A review of the written reports showed that the clinical reporting for HLA-B*15:02 detection should be improved. Some essential information was missing, most notably laboratory information/contact, therapeutic recommendations, and methodology. External quality assessment is valuable in assessing and improving the quality of laboratory testing of HLA-B*15:02 allele. © 2017 Wiley Periodicals, Inc.
Functions of external cues in prospective memory.
DOT National Transportation Integrated Search
1995-02-01
A simulation of an air traffic control task was the setting for an investigation of the functions of external cues in prospective memory. External cues can support the triggering of an action or memory for the content of the action. : We focused on m...
Janssens, Sandra; Chokoshvili, Davit; Vears, Danya F; De Paepe, Anne; Borry, Pascal
2017-08-01
Carrier screening is generally performed with the aim of identifying healthy couples at risk of having a child affected with a monogenic disorder to provide them with reproductive options. Expanded carrier screening (ECS), which provides the opportunity for multiple conditions to be screened in one test, offers a more cost-effective and comprehensive option than screening for single disorders. However, implementation of ECS at a population level would have implications for genetic counseling practice. We conducted semi-structured interviews with sixteen European clinical and molecular geneticists with expertise in carrier screening to explore their views on the implementation of ECS in the clinical setting. Using inductive content analysis, we identified content categories relevant to the pre- and post-test settings. Participants believed ECS would ideally be targeted at couples before pregnancy. There was some disagreement regarding the acceptability of performing ECS in individuals, with several participants actively opposing individual-based screening. In addition, participants discussed the importance of ensuring informed and voluntary participation in ECS, recommending measures to minimize external pressure on prospective parents to undergo testing. A need for adequate counseling to foster informed, autonomous reproductive decision-making and provide support for couples found to be at risk was emphasized. Practical challenges in optimizing pre-test education and post-test counseling should not be underestimated and they should be carefully addressed before implementing ECS in the clinical setting.
Dombert, Beate; Mokros, Andreas; Brückner, Eva; Schlegl, Verena; Antfolk, Jan; Bäckström, Anna; Zappalà, Angelo; Osterheider, Michael; Santtila, Pekka
2013-12-01
The implicit assessment of pedophilic sexual interest through viewing-time methods necessitates visual stimuli. There are grave ethical and legal concerns against using pictures of real children, however. The present report is a summary of findings on a new set of 108 computer-generated stimuli. The images vary in terms of gender (female/male), explicitness (naked/clothed), and physical maturity (prepubescent, pubescent, and adult) of the persons depicted. A series of three studies tested the internal and external validity of the picture set. Studies 1 and 2 yielded good-to-high estimates of observer agreement with regard to stimulus maturity levels by two methods (categorization and paired comparison). Study 3 extended these findings with regard to judgments made by convicted child sexual offenders.
NASA Astrophysics Data System (ADS)
Richards, Joseph W.; Starr, Dan L.; Brink, Henrik; Miller, Adam A.; Bloom, Joshua S.; Butler, Nathaniel R.; James, J. Berian; Long, James P.; Rice, John
2012-01-01
Despite the great promise of machine-learning algorithms to classify and predict astrophysical parameters for the vast numbers of astrophysical sources and transients observed in large-scale surveys, the peculiarities of the training data often manifest as strongly biased predictions on the data of interest. Typically, training sets are derived from historical surveys of brighter, more nearby objects than those from more extensive, deeper surveys (testing data). This sample selection bias can cause catastrophic errors in predictions on the testing data because (1) standard assumptions for machine-learned model selection procedures break down and (2) dense regions of testing space might be completely devoid of training data. We explore possible remedies to sample selection bias, including importance weighting, co-training, and active learning (AL). We argue that AL—where the data whose inclusion in the training set would most improve predictions on the testing set are queried for manual follow-up—is an effective approach and is appropriate for many astronomical applications. For a variable star classification problem on a well-studied set of stars from Hipparcos and Optical Gravitational Lensing Experiment, AL is the optimal method in terms of error rate on the testing data, beating the off-the-shelf classifier by 3.4% and the other proposed methods by at least 3.0%. To aid with manual labeling of variable stars, we developed a Web interface which allows for easy light curve visualization and querying of external databases. Finally, we apply AL to classify variable stars in the All Sky Automated Survey, finding dramatic improvement in our agreement with the ASAS Catalog of Variable Stars, from 65.5% to 79.5%, and a significant increase in the classifier's average confidence for the testing set, from 14.6% to 42.9%, after a few AL iterations.
Clemente, Isabel; Aznar, Margarita; Nerín, Cristina; Bosetti, Osvaldo
2016-01-01
Inks and varnishes used in food packaging multilayer materials can contain different substances that are potential migrants when packaging is in contact with food. Although printing inks are applied on the external layer, they can migrate due to set-off phenomena. In order to assess food safety, migration tests were performed from two materials sets: set A based on paper and set B based on PET; both contained inks. Migration was performed to four food simulants (EtOH 50%, isooctane, EtOH 95% and Tenax(®)) and the volatile compounds profile was analysed by GC-MS. The effect of presence/absence of inks and varnishes and also their position in the material was studied. A total of 149 volatile compounds were found in migration from set A and 156 from set B materials, some of them came from inks. Quantitative analysis and a principal component analysis were performed in order to identify patterns among sample groups.
Is Air War College Teaching the Right Leadership Skill Sets?
2008-02-15
Following are the skill sets for strategic leaders: • Critical Thinking (includes Conceptual Competence/ Decision Making / Strategic Thinking... Decision Making / Strategic Thinking) • Creative Thinking (includes Conceptual Flexibility) • Integrating internal and external environments • Long Range... Making / Strategic Thinking Yes Integrating Internal and External Environments Yes Long Range Vision Yes Team Performance Facilitation/Team Building
ERIC Educational Resources Information Center
Wagler, Ron; Wagler, Amy
2012-01-01
This study investigated if the external morphology of an insect had a negative effect on United States (US) preservice elementary teacher's attitudes toward insects and beliefs concerning the likelihood of incorporating insects into future science education settings. 270 US kindergarten through sixth grade preservice elementary teachers…
Measurement of external forces and torques on a large pointing system
NASA Technical Reports Server (NTRS)
Morenus, R. C.
1980-01-01
Methods of measuring external forces and torques are discussed, in general and as applied to the Large Pointing System wind tunnel tests. The LPS tests were in two phases. The first test was a preliminary test of three models representing coelostat, heliostat, and on-gimbal telescope configurations. The second test explored the coelostat configuration in more detail. The second test used a different setup for measuring external loads. Some results are given from both tests.
49 CFR 192.469 - External corrosion control: Test stations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 3 2010-10-01 2010-10-01 false External corrosion control: Test stations. 192.469... TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Requirements for Corrosion Control § 192.469 External corrosion control: Test stations. Each pipeline under cathodic protection...
49 CFR 192.469 - External corrosion control: Test stations.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 3 2011-10-01 2011-10-01 false External corrosion control: Test stations. 192.469... TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Requirements for Corrosion Control § 192.469 External corrosion control: Test stations. Each pipeline under cathodic protection...
49 CFR 192.469 - External corrosion control: Test stations.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 3 2013-10-01 2013-10-01 false External corrosion control: Test stations. 192.469... TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Requirements for Corrosion Control § 192.469 External corrosion control: Test stations. Each pipeline under cathodic protection...
49 CFR 192.469 - External corrosion control: Test stations.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 3 2014-10-01 2014-10-01 false External corrosion control: Test stations. 192.469... TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Requirements for Corrosion Control § 192.469 External corrosion control: Test stations. Each pipeline under cathodic protection...
49 CFR 192.469 - External corrosion control: Test stations.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 3 2012-10-01 2012-10-01 false External corrosion control: Test stations. 192.469... TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Requirements for Corrosion Control § 192.469 External corrosion control: Test stations. Each pipeline under cathodic protection...
Research: Testing of a Novel Portable Body Temperature Conditioner Using a Thermal Manikin.
Heller, Daniel; Heller, Alex; Moujaes, Samir; Williams, Shelley J; Hoffmann, Ryan; Sarkisian, Paul; Khalili, Kaveh; Rockenfeller, Uwe; Browder, Timothy D; Kuhls, Deborah A; Fildes, John J
2016-01-01
A battery-operated active cooling/heating device was developed to maintain thermoregulation of trauma victims in austere environments while awaiting evacuation to a hospital for further treatment. The use of a thermal manikin was adopted for this study in order to simulate load testing and evaluate the performance of this novel portable active cooling/heating device for both continuous (external power source) and battery power. The performance of the portable body temperature conditioner (PBTC) was evaluated through cooling/heating fraction tests to analyze the heat transfer between a thermal manikin and circulating water blanket to show consistent performance while operating under battery power. For the cooling/heating fraction tests, the ambient temperature was set to 15°C ± 1°C (heating) and 30°C ± 1°C (cooling). The PBTC water temperature was set to 37°C for the heating mode tests and 15°C for the cooling mode tests. The results showed consistent performance of the PBTC in terms of cooling/heating capacity while operating under both continuous and battery power. The PBTC functioned as intended and shows promise as a portable warming/cooling device for operation in the field.
NASA Astrophysics Data System (ADS)
Smith-Ferguson, Jules; Reid, Chris R.; Latty, Tanya; Beekman, Madeleine
2017-10-01
The ability to navigate through an environment is critical to most organisms’ ability to survive and reproduce. The presence of a memory system greatly enhances navigational success. Therefore, natural selection is likely to drive the creation of memory systems, even in non-neuronal organisms, if having such a system is adaptive. Here we examine if the external spatial memory system present in the acellular slime mould, Physarum polycephalum, provides an adaptive advantage for resource acquisition. P. polycephalum lays tracks of extracellular slime as it moves through its environment. Previous work has shown that the presence of extracellular slime allows the organism to escape from a trap in laboratory experiments simply by avoiding areas previously explored. Here we further investigate the benefits of using extracellular slime as an external spatial memory by testing the organism’s ability to navigate through environments of differing complexity with and without the ability to use its external memory. Our results suggest that the external memory has an adaptive advantage in ‘open’ and simple bounded environments. However, in a complex bounded environment, the extracellular slime provides no advantage, and may even negatively affect the organism’s navigational abilities. Our results indicate that the exact experimental set up matters if one wants to fully understand how the presence of extracellular slime affects the slime mould’s search behaviour.
Brushed permanent magnet DC MLC motor operation in an external magnetic field.
Yun, J; St Aubin, J; Rathee, S; Fallone, B G
2010-05-01
Linac-MR systems for real-time image-guided radiotherapy will utilize the multileaf collimators (MLCs) to perform conformal radiotherapy and tumor tracking. The MLCs would be exposed to the external fringe magnetic fields of the linac-MR hybrid systems. Therefore, an experimental investigation of the effect of an external magnetic field on the brushed permanent magnet DC motors used in some MLC systems was performed. The changes in motor speed and current were measured for varying external magnetic field strengths up to 2000 G generated by an EEV electromagnet. These changes in motor characteristics were measured for three orientations of the motor in the external magnetic field, mimicking changes in motor orientations due to installation and/or collimator rotations. In addition, the functionality of the associated magnetic motor encoder was tested. The tested motors are used with the Varian 120 leaf Millennium MLC (Maxon Motor half leaf and full leaf motors) and the Varian 52 leaf MKII MLC (MicroMo Electronics leaf motor) including a carriage motor (MicroMo Electronics). In most cases, the magnetic encoder of the motors failed prior to any damage to the gearbox or the permanent magnet motor itself. This sets an upper limit of the external magnetic field strength on the motor function. The measured limits of the external magnetic fields were found to vary by the motor type. The leaf motor used with a Varian 52 leaf MKII MLC system tolerated up to 450 +/- 10 G. The carriage motor tolerated up to 2000 +/- 10 G field. The motors used with the Varian 120 leaf Millennium MLC system were found to tolerate a maximum of 600 +/- 10 G. The current Varian MLC system motors can be used for real-time image-guided radiotherapy coupled to a linac-MR system, provided the fringe magnetic fields at their locations are below the determined tolerance levels. With the fringe magnetic fields of linac-MR systems expected to be larger than the tolerance levels determined, some form of magnetic shielding would be required.
NASA Astrophysics Data System (ADS)
Hsieh, Jui-Hua; Wang, Xiang S.; Teotico, Denise; Golbraikh, Alexander; Tropsha, Alexander
2008-09-01
The use of inaccurate scoring functions in docking algorithms may result in the selection of compounds with high predicted binding affinity that nevertheless are known experimentally not to bind to the target receptor. Such falsely predicted binders have been termed `binding decoys'. We posed a question as to whether true binders and decoys could be distinguished based only on their structural chemical descriptors using approaches commonly used in ligand based drug design. We have applied the k-Nearest Neighbor ( kNN) classification QSAR approach to a dataset of compounds characterized as binders or binding decoys of AmpC beta-lactamase. Models were subjected to rigorous internal and external validation as part of our standard workflow and a special QSAR modeling scheme was employed that took into account the imbalanced ratio of inhibitors to non-binders (1:4) in this dataset. 342 predictive models were obtained with correct classification rate (CCR) for both training and test sets as high as 0.90 or higher. The prediction accuracy was as high as 100% (CCR = 1.00) for the external validation set composed of 10 compounds (5 true binders and 5 decoys) selected randomly from the original dataset. For an additional external set of 50 known non-binders, we have achieved the CCR of 0.87 using very conservative model applicability domain threshold. The validated binary kNN QSAR models were further employed for mining the NCGC AmpC screening dataset (69653 compounds). The consensus prediction of 64 compounds identified as screening hits in the AmpC PubChem assay disagreed with their annotation in PubChem but was in agreement with the results of secondary assays. At the same time, 15 compounds were identified as potential binders contrary to their annotation in PubChem. Five of them were tested experimentally and showed inhibitory activities in millimolar range with the highest binding constant Ki of 135 μM. Our studies suggest that validated QSAR models could complement structure based docking and scoring approaches in identifying promising hits by virtual screening of molecular libraries.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-02
... Procedures C. Review of Single-Voltage External Power Supply Test Procedure D. Multiple-Voltage External...) Deletions of Existing Definitions (b) Revisions to Existing Definitions (c) Additions of New Definitions 4. Test Apparatus and General Instructions (a) Confidence Intervals (b) Temperature (c) AC Input Voltage...
A new in silico classification model for ready biodegradability, based on molecular fragments.
Lombardo, Anna; Pizzo, Fabiola; Benfenati, Emilio; Manganaro, Alberto; Ferrari, Thomas; Gini, Giuseppina
2014-08-01
Regulations such as the European REACH (Registration, Evaluation, Authorization and restriction of Chemicals) often require chemicals to be evaluated for ready biodegradability, to assess the potential risk for environmental and human health. Because not all chemicals can be tested, there is an increasing demand for tools for quick and inexpensive biodegradability screening, such as computer-based (in silico) theoretical models. We developed an in silico model starting from a dataset of 728 chemicals with ready biodegradability data (MITI-test Ministry of International Trade and Industry). We used the novel software SARpy to automatically extract, through a structural fragmentation process, a set of substructures statistically related to ready biodegradability. Then, we analysed these substructures in order to build some general rules. The model consists of a rule-set made up of the combination of the statistically relevant fragments and of the expert-based rules. The model gives good statistical performance with 92%, 82% and 76% accuracy on the training, test and external set respectively. These results are comparable with other in silico models like BIOWIN developed by the United States Environmental Protection Agency (EPA); moreover this new model includes an easily understandable explanation. Copyright © 2014 Elsevier Ltd. All rights reserved.
Fine motor skills and early comprehension of the world: two new school readiness indicators.
Grissmer, David; Grimm, Kevin J; Aiyer, Sophie M; Murrah, William M; Steele, Joel S
2010-09-01
Duncan et al. (2007) presented a new methodology for identifying kindergarten readiness factors and quantifying their importance by determining which of children's developing skills measured around kindergarten entrance would predict later reading and math achievement. This article extends Duncan et al.'s work to identify kindergarten readiness factors with 6 longitudinal data sets. Their results identified kindergarten math and reading readiness and attention as the primary long-term predictors but found no effects from social skills or internalizing and externalizing behavior. We incorporated motor skills measures from 3 of the data sets and found that fine motor skills are an additional strong predictor of later achievement. Using one of the data sets, we also predicted later science scores and incorporated an additional early test of general knowledge of the social and physical world as a predictor. We found that the test of general knowledge was by far the strongest predictor of science and reading and also contributed significantly to predicting later math, making the content of this test another important kindergarten readiness indicator. Together, attention, fine motor skills, and general knowledge are much stronger overall predictors of later math, reading, and science scores than early math and reading scores alone.
Zivkovic, Milena Z; Djuric, Sasa; Cuk, Ivan; Suzovic, Dejan; Jaric, Slobodan
2017-07-01
A range of force (F) and velocity (V) data obtained from functional movement tasks (e.g., running, jumping, throwing, lifting, cycling) performed under variety of external loads have typically revealed strong and approximately linear F-V relationships. The regression model parameters reveal the maximum F (F-intercept), V (V-intercept), and power (P) producing capacities of the tested muscles. The aim of the present study was to evaluate the level of agreement between the routinely used "multiple-load model" and a simple "two-load model" based on direct assessment of the F-V relationship from only 2 external loads applied. Twelve participants were tested on the maximum performance vertical jumps, cycling, bench press throws, and bench pull performed against a variety of different loads. All 4 tested tasks revealed both exceptionally strong relationships between the parameters of the 2 models (median R = 0.98) and a lack of meaningful differences between their magnitudes (fixed bias below 3.4%). Therefore, addition of another load to the standard tests of various functional tasks typically conducted under a single set of mechanical conditions could allow for the assessment of the muscle mechanical properties such as the muscle F, V, and P producing capacities.
Pyrolysis of reinforced polymer composites: Parameterizing a model for multiple compositions
NASA Astrophysics Data System (ADS)
Martin, Geraldine E.
A single set of material properties was developed to describe the pyrolysis of fiberglass reinforced polyester composites at multiple composition ratios. Milligram-scale testing was performed on the unsaturated polyester (UP) resin using thermogravimetric analysis (TGA) coupled with differential scanning calorimetry (DSC) to establish and characterize an effective semi-global reaction mechanism, of three consecutive first-order reactions. Radiation-driven gasification experiments were conducted on UP resin and the fiberglass composites at compositions ranging from 41 to 54 wt% resin at external heat fluxes from 30 to 70 kW m -2. The back surface temperature was recorded with an infrared camera and used as the target for inverse analysis to determine the thermal conductivity of the systematically isolated constituent species. Manual iterations were performed in a comprehensive pyrolysis model, ThermaKin. The complete set of properties was validated for the ability to reproduce the mass loss rate during gasification testing.
Kent, Jack W
2016-02-03
New technologies for acquisition of genomic data, while offering unprecedented opportunities for genetic discovery, also impose severe burdens of interpretation and penalties for multiple testing. The Pathway-based Analyses Group of the Genetic Analysis Workshop 19 (GAW19) sought reduction of multiple-testing burden through various approaches to aggregation of highdimensional data in pathways informed by prior biological knowledge. Experimental methods testedincluded the use of "synthetic pathways" (random sets of genes) to estimate power and false-positive error rate of methods applied to simulated data; data reduction via independent components analysis, single-nucleotide polymorphism (SNP)-SNP interaction, and use of gene sets to estimate genetic similarity; and general assessment of the efficacy of prior biological knowledge to reduce the dimensionality of complex genomic data. The work of this group explored several promising approaches to managing high-dimensional data, with the caveat that these methods are necessarily constrained by the quality of external bioinformatic annotation.
Role of inspectors in external review mechanisms: criteria for selection, training and appraisal.
Plebani, M
2001-07-20
There is a wide consensus that an external review mechanism, both in the form of a peer review, accreditation and certification according to the ISO 9000 series, is more than its standards. The survey process, the role of inspectors and standard interpretation contribute to the essence of the programme itself. Above all, the criteria used for the selection, training and appraisal of inspectors are of paramount importance. While the ISO norms do not require certification bodies to employ "peer reviewers" for the healthcare sector, experience in this sector is the main criterion for recruiting inspectors in accreditation and peer review programmes. However, the ISO/IEC Guide 58, for the setting up and operation of a laboratory accreditation body, specifies that inspectors should have appropriate technical knowledge of the specific calibrations, tests or types of calibration or tests for which accreditation is sought. Training, updating and assessment of inspectors are clearly defined under ISO, but are also systematic under accreditation programmes. Part-time inspectors who are professionals currently practising in a healthcare facility and are in touch with the day-to-day work reality are preferred for accreditation programmes which have self-regulation, education and quality improvement as their main concerns, while full-time and external inspectors are used in external review mechanisms with registration and certification as their main concerns. As well as harmonising the standards for accreditation, it is important to obtain consensus on the criteria to use for the selection, training and assessment of inspectors in order to ensure that different national or international programmes gain mutual recognition.
Ng, Hui Wen; Doughty, Stephen W; Luo, Heng; Ye, Hao; Ge, Weigong; Tong, Weida; Hong, Huixiao
2015-12-21
Some chemicals in the environment possess the potential to interact with the endocrine system in the human body. Multiple receptors are involved in the endocrine system; estrogen receptor α (ERα) plays very important roles in endocrine activity and is the most studied receptor. Understanding and predicting estrogenic activity of chemicals facilitates the evaluation of their endocrine activity. Hence, we have developed a decision forest classification model to predict chemical binding to ERα using a large training data set of 3308 chemicals obtained from the U.S. Food and Drug Administration's Estrogenic Activity Database. We tested the model using cross validations and external data sets of 1641 chemicals obtained from the U.S. Environmental Protection Agency's ToxCast project. The model showed good performance in both internal (92% accuracy) and external validations (∼ 70-89% relative balanced accuracies), where the latter involved the validations of the model across different ER pathway-related assays in ToxCast. The important features that contribute to the prediction ability of the model were identified through informative descriptor analysis and were related to current knowledge of ER binding. Prediction confidence analysis revealed that the model had both high prediction confidence and accuracy for most predicted chemicals. The results demonstrated that the model constructed based on the large training data set is more accurate and robust for predicting ER binding of chemicals than the published models that have been developed using much smaller data sets. The model could be useful for the evaluation of ERα-mediated endocrine activity potential of environmental chemicals.
Finkelman, Matthew D; Smits, Niels; Kulich, Ronald J; Zacharoff, Kevin L; Magnuson, Britta E; Chang, Hong; Dong, Jinghui; Butler, Stephen F
2017-07-01
The Screener and Opioid Assessment for Patients with Pain-Revised (SOAPP-R) is a 24-item questionnaire designed to assess risk of aberrant medication-related behaviors in chronic pain patients. The introduction of short forms of the SOAPP-R may save time and increase utilization by practitioners. To develop and evaluate candidate SOAPP-R short forms. Retrospective study. Pain centers. Four hundred and twenty-eight patients with chronic noncancer pain. Subjects had previously been administered the full-length version of the SOAPP-R and been categorized as positive or negative for aberrant medication-related behaviors via the Aberrant Drug Behavior Index (ADBI). Short forms of the SOAPP-R were developed using lasso logistic regression. Sensitivity, specificity, and area under the curve (AUC) of all forms were calculated with respect to the ADBI using the complete data set, training-test analysis, and 10-fold cross-validation. The coefficient alpha of each form was also calculated. An external set of 12 pain practitioners reviewed the forms for content. In the complete data set analysis, a form of 12 items exhibited sensitivity, specificity, and AUC greater than or equal to those of the full-length SOAPP-R (which were 0.74, 0.67, and 0.76, respectively). The short form had a coefficient alpha of 0.76. In the training-test analysis and 10-fold cross-validation, it exhibited an AUC value within 0.01 of that of the full-length SOAPP-R. The majority of external practitioners reported a preference for this short form. The 12-item version of the SOAPP-R has potential as a short risk screener and should be tested prospectively. © 2016 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
Porter, Jared M.; Nolan, Russell P.; Ostrowski, Erik J.; Wulf, Gabriele
2010-01-01
The primary purpose of this study was to investigate if focusing attention externally produced faster movement times compared to instructions that focused attention internally or a control set of instructions that did not explicitly focus attention when performing an agility task. A second purpose of the study was to measure participants’ focus of attention during practice by use of a questionnaire. Participants (N = 20) completed 15 trials of an agility “L” run following instructions designed to induce an external (EXT), internal (INT) attentional focus or a control (CON) set of instructions inducing no specific focus of attention. Analysis revealed when participants followed the EXT instructions they had significantly faster movement times compared to when they followed the INT and CON set of instructions; consistent with previous research the INT and CON movement times were not significantly different from each other. Qualitative data showed when participants were in the external condition they focused externally 67% of the time. When they were in the internal condition they focused internally 76% of the time, and when they were in the control condition they did not use an internal or external focus of attention 77% of the time. Qualitative data also revealed participants in the EXT, INT, and CON conditions switched their focus of attention at a frequency of 27, 35, and 51% respectively. PMID:21833271
Improved definition of crustal anomalies for Magsat data
NASA Technical Reports Server (NTRS)
1981-01-01
A scheme was developed for separating the portions of the magnetic field measured by the Magsat 1 satellite that arise from internal and external sources. To test this method, a set of sample coefficients were used to compute the field values along a simulated satellite orbit. This data was then used to try to recover the original coefficients. Matrix inversion and recursive least squares methods were used to solve for the input coefficients. The accuracy of the two methods are compared.
TACT: A Set of MSC/PATRAN- and MSC/NASTRAN- based Modal Correlation Tools
NASA Technical Reports Server (NTRS)
Marlowe, Jill M.; Dixon, Genevieve D.
1998-01-01
This paper describes the functionality and demonstrates the utility of the Test Analysis Correlation Tools (TACT), a suite of MSC/PATRAN Command Language (PCL) tools which automate the process of correlating finite element models to modal survey test data. The initial release of TACT provides a basic yet complete set of tools for performing correlation totally inside the PATRAN/NASTRAN environment. Features include a step-by-step menu structure, pre-test accelerometer set evaluation and selection, analysis and test result export/import in Universal File Format, calculation of frequency percent difference and cross-orthogonality correlation results using NASTRAN, creation and manipulation of mode pairs, and five different ways of viewing synchronized animations of analysis and test modal results. For the PATRAN-based analyst, TACT eliminates the repetitive, time-consuming and error-prone steps associated with transferring finite element data to a third-party modal correlation package, which allows the analyst to spend more time on the more challenging task of model updating. The usefulness of this software is presented using a case history, the correlation for a NASA Langley Research Center (LaRC) low aspect ratio research wind tunnel model. To demonstrate the improvements that TACT offers the MSC/PATRAN- and MSC/DIASTRAN- based structural analysis community, a comparison of the modal correlation process using TACT within PATRAN versus external third-party modal correlation packages is presented.
Bartlett, John M S; Ibrahim, Merdol; Jasani, Bharat; Morgan, John M; Ellis, Ian; Kay, Elaine; Magee, Hilary; Barnett, Sarah; Miller, Keith
2007-01-01
Background and Aims Trastuzumab provides clinical benefit for advanced and early breast cancer patients whose tumours over‐express or have gene amplification of the HER2 oncogene. The UK National External Quality Assessment Scheme (NEQAS) for immunohistochemical testing was established to assess and improve the quality of HER2 immunohistochemical testing. However, until recently, no provision was available for HER2 fluorescence in situ hybridisation (FISH) testing. A pilot scheme was set up to review the performance of FISH testing in clinical diagnostic laboratories. Methods FISH was performed in 6 reference and 31 participating laboratories using a cell line panel with known HER2 status. Results Using results from reference laboratories as a criterion for acceptable performance, 60% of all results returned by participants were appropriate and 78% either appropriate or acceptable. However, 22.4% of results returned were deemed inappropriate, including 13 cases (4.2%) where a misdiagnosis would have been made had these been clinical specimens. Conclusions The results of three consecutive runs show that both reference laboratories and a proportion of routine clinical diagnostic (about 25%) centres can consistently achieve acceptable quality control of HER2 testing. Data from a significant proportion of participating laboratories show that further steps are required, including those taken via review of performance under schemes such as NEQAS, to improve quality of HER2 testing by FISH in the “real world”. PMID:16963466
[Economic impact of external laboratory test].
Takura, Tomoyuki
2006-11-01
The realities of the spread and the aim of the introduction, and an economical influence of an external laboratory tests were researched. As a result, 90% or more the ratio to have consigned the external whole became clear. But it is preferable to correspond about inspection item of about 70% in own facilities because of the characteristic of the medical institution and the inspection item. Moreover, when correct the unbridgeable gulf of characteristic of the realities of spread of present external laboratory tests inspection and the ranging of ideal external laboratory tests inspection that specialist thinks about, the needed medical payment was thought that the investment of about 50 billion yen a year was necessary to expand the inspection in own facilities, by calculated based on the stochastic model.
CADASTER QSPR Models for Predictions of Melting and Boiling Points of Perfluorinated Chemicals.
Bhhatarai, Barun; Teetz, Wolfram; Liu, Tao; Öberg, Tomas; Jeliazkova, Nina; Kochev, Nikolay; Pukalov, Ognyan; Tetko, Igor V; Kovarich, Simona; Papa, Ester; Gramatica, Paola
2011-03-14
Quantitative structure property relationship (QSPR) studies on per- and polyfluorinated chemicals (PFCs) on melting point (MP) and boiling point (BP) are presented. The training and prediction chemicals used for developing and validating the models were selected from Syracuse PhysProp database and literatures. The available experimental data sets were split in two different ways: a) random selection on response value, and b) structural similarity verified by self-organizing-map (SOM), in order to propose reliable predictive models, developed only on the training sets and externally verified on the prediction sets. Individual linear and non-linear approaches based models developed by different CADASTER partners on 0D-2D Dragon descriptors, E-state descriptors and fragment based descriptors as well as consensus model and their predictions are presented. In addition, the predictive performance of the developed models was verified on a blind external validation set (EV-set) prepared using PERFORCE database on 15 MP and 25 BP data respectively. This database contains only long chain perfluoro-alkylated chemicals, particularly monitored by regulatory agencies like US-EPA and EU-REACH. QSPR models with internal and external validation on two different external prediction/validation sets and study of applicability-domain highlighting the robustness and high accuracy of the models are discussed. Finally, MPs for additional 303 PFCs and BPs for 271 PFCs were predicted for which experimental measurements are unknown. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
The LED and fiber based calibration system for the photomultiplier array of SNO+
NASA Astrophysics Data System (ADS)
Seabra, L.; Alves, R.; Andringa, S.; Bradbury, S.; Carvalho, J.; Clark, K.; Coulter, I.; Descamps, F.; Falk, L.; Gurriana, L.; Kraus, C.; Lefeuvre, G.; Maio, A.; Maneira, J.; Mottram, M.; Peeters, S.; Rose, J.; Sinclair, J.; Skensved, P.; Waterfield, J.; White, R.; Wilson, J.; SNO+ Collaboration
2015-02-01
A new external LED/fiber light injection calibration system was designed for the calibration and monitoring of the photomultiplier array of the SNO+ experiment at SNOLAB. The goal of the calibration system is to allow an accurate and regular measurement of the photomultiplier array's performance, while minimizing the risk of radioactivity ingress. The choice in SNO+ was to use a set of optical fiber cables to convey into the detector the light pulses produced by external LEDs. The quality control was carried out using a modified test bench that was used in QC of optical fibers for TileCal/ATLAS. The optical fibers were characterized for transmission, timing and angular dispersions. This article describes the setups used for the characterization and quality control of the system based on LEDs and optical fibers and their results.
NASA Technical Reports Server (NTRS)
Fossler, I. H.; Cole, P.
1972-01-01
Experimental aerodynamic investigations were conducted on a .006 scale model of the space shuttle 040-A orbiter and its external fuel tank utilizing the NASA/MFSC dual sting support system in the MFSC 14 x 14 inch Trisonic Wind Tunnel. Normal force, pitching moment and axial force components were recorded simultaneously on the orbiter and the tank at selected tank field positions beneath the orbiter as both models were pitched through an angle of attack range of -5 deg to 20 deg. Incidence angles between orbiter and tank of 0 deg, 5 deg, 10 deg and 15 deg were investigated. During these tests Mach number was set at 0.6, 2.0 and 4.0.
NASA Technical Reports Server (NTRS)
Shovlin, M. D.
1977-01-01
Interior and exterior fuselage noise levels were measured on NASA's C-8A Augmentor Wing Jet-STOL Research Aircraft in order to provide design information for the Quiet Short-Haul Research Aircraft (QSRA), which will use a modified C-8A fuselage. The noise field was mapped by 11 microphones located internally and externally in three areas: mid-fuselage, aft fuselage, and on the flight deck. Noise levels were recorded at four power settings varying from takeoff to flight idle and were plotted in one-third octave band spectra. The overall sound pressure levels of the external noise field were compared to previous tests and found to correlate well with engine primary thrust levels. Fuselage values were 145 + or - 3 dB over the aircraft's normal STOL operating range.
Thorborg, K; Bandholm, T; Schick, M; Jensen, J; Hölmich, P
2013-08-01
Handheld dynamometry (HHD) is a promising tool for obtaining reliable hip strength measurements in the clinical setting, but intertester reliability has been questioned, especially in situations where testers exhibit differences in upper-extremity muscle strength (male vs female). The purpose of this study was to examine the intertester reliability concerning strength assessments of hip abduction, adduction, external and internal rotation, flexion and extension using HHD, and to test whether systematic differences in test values exist between testers of different upper-extremity strength. Fifty healthy individuals (29 women), aged 25 ± 5 years were included. Two physiotherapist students (one female, one male) of different upper-extremity strength performed the measurements. The tester order and strength test order were randomized. Intraclass correlation coefficients were used to quantify reliability, and ranged from 0.82 to 0.91 for the six strength test. The female tester systematically measured lower strength values for all isometric strength tests (P < 0.05). In hip strength assessments using HHD, systematic bias exists between testers of different sex, which is likely explained by differences in upper-extremity strength. Hence, to improve intertester reliability, the dynamometer likely needs external fixation, as this will eliminate the influence of differences in upper-extremity strength between testers. © 2011 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Quantitative structure-activity relationship modeling of rat acute toxicity by oral exposure.
Zhu, Hao; Martin, Todd M; Ye, Lin; Sedykh, Alexander; Young, Douglas M; Tropsha, Alexander
2009-12-01
Few quantitative structure-activity relationship (QSAR) studies have successfully modeled large, diverse rodent toxicity end points. In this study, a comprehensive data set of 7385 compounds with their most conservative lethal dose (LD(50)) values has been compiled. A combinatorial QSAR approach has been employed to develop robust and predictive models of acute toxicity in rats caused by oral exposure to chemicals. To enable fair comparison between the predictive power of models generated in this study versus a commercial toxicity predictor, TOPKAT (Toxicity Prediction by Komputer Assisted Technology), a modeling subset of the entire data set was selected that included all 3472 compounds used in TOPKAT's training set. The remaining 3913 compounds, which were not present in the TOPKAT training set, were used as the external validation set. QSAR models of five different types were developed for the modeling set. The prediction accuracy for the external validation set was estimated by determination coefficient R(2) of linear regression between actual and predicted LD(50) values. The use of the applicability domain threshold implemented in most models generally improved the external prediction accuracy but expectedly led to the decrease in chemical space coverage; depending on the applicability domain threshold, R(2) ranged from 0.24 to 0.70. Ultimately, several consensus models were developed by averaging the predicted LD(50) for every compound using all five models. The consensus models afforded higher prediction accuracy for the external validation data set with the higher coverage as compared to individual constituent models. The validated consensus LD(50) models developed in this study can be used as reliable computational predictors of in vivo acute toxicity.
ERIC Educational Resources Information Center
Lehrer, Joanne S.; Lemay, Lise; Bigras, Nathalie
2015-01-01
The current study examined how parental perceptions of child care quality were related to external quality ratings and considered how parental perceptions of quality varied according to child care context (home-based or centre-based settings). Parents of 179 4-year-old children who attended child care centres (n = 141) and home-based settings…
External Prior Guided Internal Prior Learning for Real-World Noisy Image Denoising
NASA Astrophysics Data System (ADS)
Xu, Jun; Zhang, Lei; Zhang, David
2018-06-01
Most of existing image denoising methods learn image priors from either external data or the noisy image itself to remove noise. However, priors learned from external data may not be adaptive to the image to be denoised, while priors learned from the given noisy image may not be accurate due to the interference of corrupted noise. Meanwhile, the noise in real-world noisy images is very complex, which is hard to be described by simple distributions such as Gaussian distribution, making real noisy image denoising a very challenging problem. We propose to exploit the information in both external data and the given noisy image, and develop an external prior guided internal prior learning method for real noisy image denoising. We first learn external priors from an independent set of clean natural images. With the aid of learned external priors, we then learn internal priors from the given noisy image to refine the prior model. The external and internal priors are formulated as a set of orthogonal dictionaries to efficiently reconstruct the desired image. Extensive experiments are performed on several real noisy image datasets. The proposed method demonstrates highly competitive denoising performance, outperforming state-of-the-art denoising methods including those designed for real noisy images.
Bitter or not? BitterPredict, a tool for predicting taste from chemical structure.
Dagan-Wiener, Ayana; Nissim, Ido; Ben Abu, Natalie; Borgonovo, Gigliola; Bassoli, Angela; Niv, Masha Y
2017-09-21
Bitter taste is an innately aversive taste modality that is considered to protect animals from consuming toxic compounds. Yet, bitterness is not always noxious and some bitter compounds have beneficial effects on health. Hundreds of bitter compounds were reported (and are accessible via the BitterDB http://bitterdb.agri.huji.ac.il/dbbitter.php ), but numerous additional bitter molecules are still unknown. The dramatic chemical diversity of bitterants makes bitterness prediction a difficult task. Here we present a machine learning classifier, BitterPredict, which predicts whether a compound is bitter or not, based on its chemical structure. BitterDB was used as the positive set, and non-bitter molecules were gathered from literature to create the negative set. Adaptive Boosting (AdaBoost), based on decision trees machine-learning algorithm was applied to molecules that were represented using physicochemical and ADME/Tox descriptors. BitterPredict correctly classifies over 80% of the compounds in the hold-out test set, and 70-90% of the compounds in three independent external sets and in sensory test validation, providing a quick and reliable tool for classifying large sets of compounds into bitter and non-bitter groups. BitterPredict suggests that about 40% of random molecules, and a large portion (66%) of clinical and experimental drugs, and of natural products (77%) are bitter.
Oosterwijk, Suzanne; Mackey, Scott; Wilson-Mendenhall, Christine; Winkielman, Piotr; Paulus, Martin P.
2015-01-01
According to embodied cognition theories concepts are contextually-situated and grounded in neural systems that produce experiential states. This view predicts that processing mental state concepts recruits neural regions associated with different aspects of experience depending on the context in which people understand a concept. This neuroimaging study tested this prediction using a set of sentences that described emotional (e.g., fear, joy) and non-emotional (e.g., thinking, hunger) mental states with internal focus (i.e. focusing on bodily sensations and introspection) or external focus (i.e. focusing on expression and action). Consistent with our predictions, data suggested that the inferior frontal gyrus, a region associated with action representation, was engaged more by external than internal sentences. By contrast, the ventromedial prefrontal cortex, a region associated with the generation of internal states, was engaged more by internal emotion sentences than external sentence categories. Similar patterns emerged when we examined the relationship between neural activity and independent ratings of sentence focus. Furthermore, ratings of emotion were associated with activation in the medial prefrontal cortex, whereas ratings of activity were associated with activation in the inferior frontal gyrus. These results suggest that mental state concepts are represented in a dynamic way, using context-relevant interoceptive and sensorimotor resources. PMID:25748274
DIDEM - An integrated model for comparative health damage costs calculation of air pollution
NASA Astrophysics Data System (ADS)
Ravina, Marco; Panepinto, Deborah; Zanetti, Maria Chiara
2018-01-01
Air pollution represents a continuous hazard to human health. Administration, companies and population need efficient indicators of the possible effects given by a change in decision, strategy or habit. The monetary quantification of health effects of air pollution through the definition of external costs is increasingly recognized as a useful indicator to support decision and information at all levels. The development of modelling tools for the calculation of external costs can provide support to analysts in the development of consistent and comparable assessments. In this paper, the DIATI Dispersion and Externalities Model (DIDEM) is presented. The DIDEM model calculates the delta-external costs of air pollution comparing two alternative emission scenarios. This tool integrates CALPUFF's advanced dispersion modelling with the latest WHO recommendations on concentration-response functions. The model is based on the impact pathway method. It was designed to work with a fine spatial resolution and a local or national geographic scope. The modular structure allows users to input their own data sets. The DIDEM model was tested on a real case study, represented by a comparative analysis of the district heating system in Turin, Italy. Additional advantages and drawbacks of the tool are discussed in the paper. A comparison with other existing models worldwide is reported.
Kinship foster care among African American youth: Interaction effects at multiple contextual levels
Rufa, Anne K.; Fowler, Patrick J.
2016-01-01
This study investigated the effects of kinship foster care on mental health outcomes among African American youth. Longitudinal data were used from a nationally representative sample of children and adolescents who were the subject of child protective services investigation from 1999 to 2000 (n=5,501). The secondary analyses focused on African American youth (n=225) placed into foster care. In structured interviews, current caregivers reported on youth internalizing and externalizing behaviors immediately following placement into out-of-home care and 18-months later. Path analysis tested a theoretical model that compared placements with kin to other formal out-of-home arrangements in context of setting characteristics, including aspects of caregiver and neighborhood disorder. Results suggested significant increases in internalizing symptoms over time for youth with more baseline mental health problems, as well as those placed in more distressed neighborhoods. Increased externalizing symptoms occurred among youth with greater baseline behavior problems, those placed in more problematic neighborhoods, and youth who experienced a placement change between assessments. Additionally, a combination of placement characteristics predicted increases in externalizing problems; youth placed in kinship foster care with older caregivers in poorer health exhibited greater increases in externalizing problems. Findings highlighted important contextual considerations for out-of-home placement among African American youth. PMID:26924865
ERIC Educational Resources Information Center
Jensen, Joseph N.; Hite, Steven J.; Hite, Julie M.; Randall, E. Vance
2017-01-01
Standardized testing is an external control mechanism for K-12 public schools. Principals, nested between internal and external influences, must manage the tension created by testing's roles as both an internal improvement tool and as an external control mechanism. Five competing narratives, each shaped by author academic background, significantly…
Nayana, M Ravi Shashi; Sekhar, Y Nataraja; Nandyala, Haritha; Muttineni, Ravikumar; Bairy, Santosh Kumar; Singh, Kriti; Mahmood, S K
2008-10-01
In the present study, a series of 179 quinoline and quinazoline heterocyclic analogues exhibiting inhibitory activity against Gastric (H+/K+)-ATPase were investigated using the comparative molecular field analysis (CoMFA) and comparative molecular similarity indices (CoMSIA) methods. Both the models exhibited good correlation between the calculated 3D-QSAR fields and the observed biological activity for the respective training set compounds. The most optimal CoMFA and CoMSIA models yielded significant leave-one-out cross-validation coefficient, q(2) of 0.777, 0.744 and conventional cross-validation coefficient, r(2) of 0.927, 0.914 respectively. The predictive ability of generated models was tested on a set of 52 compounds having broad range of activity. CoMFA and CoMSIA yielded predicted activities for test set compounds with r(pred)(2) of 0.893 and 0.917 respectively. These validation tests not only revealed the robustness of the models but also demonstrated that for our models r(pred)(2) based on the mean activity of test set compounds can accurately estimate external predictivity. The factors affecting activity were analyzed carefully according to standard coefficient contour maps of steric, electrostatic, hydrophobic, acceptor and donor fields derived from the CoMFA and CoMSIA. These contour plots identified several key features which explain the wide range of activities. The results obtained from models offer important structural insight into designing novel peptic-ulcer inhibitors prior to their synthesis.
Intelligent rear light for compensation of environmental effects on car visibility
NASA Astrophysics Data System (ADS)
Gruner, Roman; Schubert, Jorg
2004-01-01
LIDAR remote sensing technology has not only applications in geographical, atmospheric or biological sciences but it can also play an important role in the everyday life. Within the last 10 years statistics of European car traffic has shown that about one third of all accidents go back to darkness and poor road conditions. A system collecting information about visibility and distance to following vehicles and setting appropriate rear light intensities could provide a much safer road travel under various environmental conditions. The system that is being developed co-operates with a dirt and brightness sensor to take into account these various external influences on an automobile and applies them to the operation of the rear light. The developed sensors are integrated in an advanced micro-system and capable of providing external environmental data for automatic brightness control within a requested range of light output for constant perceptibility of light signals to the following traffic. This conference gives further information about: (1) construction, optical and laser parameters, (2) application in rear light systems, (3) measurement characteristics, (4) test equipment (LIDAR_Probe), (5) measurement results, test rides, raw data.
Critical Current Test of Liquid Hydrogen Cooled HTC Superconductors under External Magnetic Field
NASA Astrophysics Data System (ADS)
Shirai, Yasuyuki; Shiotsu, Masahiro; Tatsumoto, Hideki; Kobayashi, Hiroaki; Naruo, Yoshihiro; Nonaka, Satoshi; Inatani, Yoshifumi
High-Tc (HTC) superconductors including MgB2 will show excellent properties under temperature of Liquid Hydrogen (LH2:20K), which has large latent heat and low viscosity coefficient. In order to design and fabricate the LH2 cooled superconducting energy devices, we must clear the cooling property of LH2 for superconductors, the cooling system and safety design of LH2 cooled superconducting devices and electro-magnetic property evaluation of superconductors (BSCCO, REBCO and MgB2) and their magnets cooled by LH2. As the first step of the study, an experimental setup which can be used for investigating heat transfer characteristics of LH2 in a pool and also in forced flow (circulation loop with a pump), and also for evaluation of electro-magnetic properties of LH2 cooled superconductors under external magnetic field (up to 7 T). In this paper, we will show a short sketch of the experimental set-up, practical experiences in safety operation of liquid hydrogen cooling system and example test results of critical current evaluation of HTC superconductors cooled by LH2.
NASA Technical Reports Server (NTRS)
Kharkovsky, S.; Case, J. T.; Zoughi, R.; Hepburn, F.
2005-01-01
The Space Shuttle Columbia's catastrophic accident emphasizes the growing need for developing and applying effective, robust and life-cycle oriented nondestructive testing (NDT) methods for inspecting the shuttle external fuel tank spray on foam insulation (SOFI) and its protective acreage heat tiles. Millimeter wave NDT techniques were one of the methods chosen for evaluating their potential for inspecting these structures. Several panels with embedded anomalies (mainly voids) were produced and tested for this purpose. Near-field and far-field millimeter wave NDT methods were used for producing millimeter wave images of the anomalies in SOFI panel and heat tiles. This paper presents the results of an investigation for the purpose of detecting localized anomalies in two SOFI panels and a set of heat tiles. To this end, reflectometers at a relatively wide range of frequencies (Ka-band (26.5 - 40 GHz) to W-band (75 - 110 GHz)) and utilizing different types of radiators were employed. The results clearly illustrate the utility of these methods for this purpose.
Kanai, Masashi; Okamoto, Kazuya; Yamamoto, Yosuke; Yoshioka, Akira; Hiramoto, Shuji; Nozaki, Akira; Nishikawa, Yoshitaka; Yamaguchi, Daisuke; Tomono, Teruko; Nakatsui, Masahiko; Baba, Mika; Morita, Tatsuya; Matsumoto, Shigemi; Kuroda, Tomohiro; Okuno, Yasushi; Muto, Manabu
2017-01-01
Background We aimed to develop an adaptable prognosis prediction model that could be applied at any time point during the treatment course for patients with cancer receiving chemotherapy, by applying time-series real-world big data. Methods Between April 2004 and September 2014, 4,997 patients with cancer who had received systemic chemotherapy were registered in a prospective cohort database at the Kyoto University Hospital. Of these, 2,693 patients with a death record were eligible for inclusion and divided into training (n = 1,341) and test (n = 1,352) cohorts. In total, 3,471,521 laboratory data at 115,738 time points, representing 40 laboratory items [e.g., white blood cell counts and albumin (Alb) levels] that were monitored for 1 year before the death event were applied for constructing prognosis prediction models. All possible prediction models comprising three different items from 40 laboratory items (40C3 = 9,880) were generated in the training cohort, and the model selection was performed in the test cohort. The fitness of the selected models was externally validated in the validation cohort from three independent settings. Results A prognosis prediction model utilizing Alb, lactate dehydrogenase, and neutrophils was selected based on a strong ability to predict death events within 1–6 months and a set of six prediction models corresponding to 1,2, 3, 4, 5, and 6 months was developed. The area under the curve (AUC) ranged from 0.852 for the 1 month model to 0.713 for the 6 month model. External validation supported the performance of these models. Conclusion By applying time-series real-world big data, we successfully developed a set of six adaptable prognosis prediction models for patients with cancer receiving chemotherapy. PMID:28837592
Fetomaternal hemorrhage during external cephalic version.
Boucher, Marc; Marquette, Gerald P; Varin, Jocelyne; Champagne, Josette; Bujold, Emmanuel
2008-07-01
To estimate the frequency and volume of fetomaternal hemorrhage during external cephalic version for term breech singleton fetuses and to identify risk factors involved with this complication. A prospective observational study was performed including all patients undergoing a trial of external cephalic version for a breech presentation of at least 36 weeks of gestation between 1987 and 2001 in our center. A search for fetal erythrocytes using the standard Kleihauer-Betke test was obtained before and after each external cephalic version. The frequency and volume of fetomaternal hemorrhage were calculated. Putative risk factors for fetomaternal hemorrhage were evaluated by chi(2) test and Mann-Whitney U test. A Kleihauer-Betke test result was available before and after 1,311 trials of external cephalic version. The Kleihauer-Betke test was positive in 67 (5.1%) before the procedure. Of the 1,244 women with a negative Kleihauer-Betke test before external cephalic version, 30 (2.4%) had a positive Kleihauer-Betke test after the procedure. Ten (0.8%) had an estimated fetomaternal hemorrhage greater than 1 mL, and one (0.08%) had an estimated fetomaternal hemorrhage greater than 30 mL. The risk of fetomaternal hemorrhage was not influenced by parity, gestational age, body mass index, number of attempts at version, placental location, or amniotic fluid index. The risk of detectable fetomaternal hemorrhage during external cephalic version was 2.4%, with fetomaternal hemorrhage more than 30 mL in less than 0.1% of cases. These data suggest that the performance of a Kleihauer-Betke test is unwarranted in uneventful external cephalic version and that in Rh-negative women, no further Rh immune globulin is necessary other than the routine 300-microgram dose at 28 weeks of gestation and postpartum. II.
Escadafal, Camille; Olschläger, Stephan; Avšič-Županc, Tatjana; Papa, Anna; Vanhomwegen, Jessica; Wölfel, Roman; Mirazimi, Ali; Teichmann, Anette; Donoso-Mantke, Oliver; Niedrig, Matthias
2012-01-01
Crimean-Congo hemorrhagic fever (CCHF) is a zoonosis caused by a Nairovirus of the family Bunyaviridae. Infection is transmitted to humans mostly by Hyalomma ticks and also by direct contact with the blood or tissues of infected humans or viremic livestock. Clinical features usually include a rapid progression characterized by hemorrhage, myalgia and fever, with a lethality rate up to 30%. CCHF is one of the most widely distributed viral hemorrhagic fevers and has been reported in Africa, the Middle East and Asia, as well as parts of Europe. There is no approved vaccine or specific treatment against CCHF virus (CCHFV) infections. In this context, an accurate diagnosis as well as a reliable surveillance of CCHFV infections is essential. Diagnostic techniques include virus culture, serology and molecular methods, which are now increasingly used. The European Network for the Diagnostics of "Imported" Viral Diseases organized the first international external quality assessment of CCHVF molecular diagnostics in 2011 to assess the efficiency and accurateness of CCHFV molecular methods applied by expert laboratories. A proficiency test panel of 15 samples was distributed to the participants including 10 different CCHFV preparations generated from infected cell cultures, a preparation of plasmid cloned with the nucleoprotein of CCHFV, two CCHFV RNA preparations and two negative controls. Forty-four laboratories worldwide participated in the EQA study and 53 data sets were received. Twenty data sets (38%) met all criteria with optimal performance, 10 (19%) with acceptable performance, while 23 (43%) reported results showing a need for improvement. Differences in performance depended on the method used, the type of strain tested, the concentration of the sample tested and the laboratory performing the test. These results indicate that there is still a need for improving testing conditions and standardizing protocols for the molecular detection of Crimean-Congo hemorrhagic fever virus.
Escadafal, Camille; Ölschläger, Stephan; Avšič-Županc, Tatjana; Papa, Anna; Vanhomwegen, Jessica; Wölfel, Roman; Mirazimi, Ali; Teichmann, Anette; Donoso-Mantke, Oliver; Niedrig, Matthias
2012-01-01
Crimean-Congo hemorrhagic fever (CCHF) is a zoonosis caused by a Nairovirus of the family Bunyaviridae. Infection is transmitted to humans mostly by Hyalomma ticks and also by direct contact with the blood or tissues of infected humans or viremic livestock. Clinical features usually include a rapid progression characterized by hemorrhage, myalgia and fever, with a lethality rate up to 30%. CCHF is one of the most widely distributed viral hemorrhagic fevers and has been reported in Africa, the Middle East and Asia, as well as parts of Europe. There is no approved vaccine or specific treatment against CCHF virus (CCHFV) infections. In this context, an accurate diagnosis as well as a reliable surveillance of CCHFV infections is essential. Diagnostic techniques include virus culture, serology and molecular methods, which are now increasingly used. The European Network for the Diagnostics of “Imported” Viral Diseases organized the first international external quality assessment of CCHVF molecular diagnostics in 2011 to assess the efficiency and accurateness of CCHFV molecular methods applied by expert laboratories. A proficiency test panel of 15 samples was distributed to the participants including 10 different CCHFV preparations generated from infected cell cultures, a preparation of plasmid cloned with the nucleoprotein of CCHFV, two CCHFV RNA preparations and two negative controls. Forty-four laboratories worldwide participated in the EQA study and 53 data sets were received. Twenty data sets (38%) met all criteria with optimal performance, 10 (19%) with acceptable performance, while 23 (43%) reported results showing a need for improvement. Differences in performance depended on the method used, the type of strain tested, the concentration of the sample tested and the laboratory performing the test. These results indicate that there is still a need for improving testing conditions and standardizing protocols for the molecular detection of Crimean-Congo hemorrhagic fever virus. PMID:22745842
Slavov, Svetoslav H; Stoyanova-Slavova, Iva; Mattes, William; Beger, Richard D; Brüschweiler, Beat J
2018-07-01
A grid-based, alignment-independent 3D-SDAR (three-dimensional spectral data-activity relationship) approach based on simulated 13 C and 15 N NMR chemical shifts augmented with through-space interatomic distances was used to model the mutagenicity of 554 primary and 419 secondary aromatic amines. A robust modeling strategy supported by extensive validation including randomized training/hold-out test set pairs, validation sets, "blind" external test sets as well as experimental validation was applied to avoid over-parameterization and build Organization for Economic Cooperation and Development (OECD 2004) compliant models. Based on an experimental validation set of 23 chemicals tested in a two-strain Salmonella typhimurium Ames assay, 3D-SDAR was able to achieve performance comparable to 5-strain (Ames) predictions by Lhasa Limited's Derek and Sarah Nexus for the same set. Furthermore, mapping of the most frequently occurring bins on the primary and secondary aromatic amine structures allowed the identification of molecular features that were associated either positively or negatively with mutagenicity. Prominent structural features found to enhance the mutagenic potential included: nitrobenzene moieties, conjugated π-systems, nitrothiophene groups, and aromatic hydroxylamine moieties. 3D-SDAR was also able to capture "true" negative contributions that are particularly difficult to detect through alternative methods. These include sulphonamide, acetamide, and other functional groups, which not only lack contributions to the overall mutagenic potential, but are known to actively lower it, if present in the chemical structures of what otherwise would be potential mutagens.
Ferrari, Thomas; Lombardo, Anna; Benfenati, Emilio
2018-05-14
Several methods exist to develop QSAR models automatically. Some are based on indices of the presence of atoms, other on the most similar compounds, other on molecular descriptors. Here we introduce QSARpy v1.0, a new QSAR modeling tool based on a different approach: the dissimilarity. This tool fragments the molecules of the training set to extract fragments that can be associated to a difference in the property/activity value, called modulators. If the target molecule share part of the structure with a molecule of the training set and differences can be explained with one or more modulators, the property/activity value of the molecule of the training set is adjusted using the value associated to the modulator(s). This tool is tested here on the n-octanol/water partition coefficient (Kow, usually expressed in logarithmic units as log Kow). It is a key parameter in risk assessment since it is a measure of hydrophobicity. Its wide spread use makes these estimation methods very useful to reduce testing costs. Using QSARpy v1.0, we obtained a new model to predict log Kow with accurate performance (RMSE 0.43 and R 2 0.94 for the external test set), comparing favorably with other programs. QSARpy is freely available on request. Copyright © 2018 Elsevier B.V. All rights reserved.
QSAR studies on triazole derivatives as sglt inhibitors via CoMFA and CoMSIA
NASA Astrophysics Data System (ADS)
Zhi, Hui; Zheng, Junxia; Chang, Yiqun; Li, Qingguo; Liao, Guochao; Wang, Qi; Sun, Pinghua
2015-10-01
Forty-six sodium-dependent glucose cotransporters-2 (SGLT-2) inhibitors with hypoglycemic activity were selected to develop three-dimensional quantitative structure-activity relationship (3D-QSAR) using comparative molecular field analysis (CoMFA) and comparative molecular similarity indices analysis (CoMSIA) models. A training set of 39 compounds were used to build up the models, which were then evaluated by a series of internal and external cross-validation techniques. A test set of 7 compounds was used for the external validation. The CoMFA model predicted a q2 value of 0.792 and an r2 value of 0.985. The best CoMSIA model predicted a q2 value of 0.633 and an r2 value of 0.895 based on a combination of steric, electrostatic, hydrophobic and hydrogen-bond acceptor effects. The predictive correlation coefficients (rpred2) of CoMFA and CoMSIA models were 0.872 and 0.839, respectively. The analysis of the contour maps from each model provided insight into the structural requirements for the development of more active sglt inhibitors, and on the basis of the models 8 new sglt inhibitors were designed and predicted.
Thermal-Hydraulic Results for the Boiling Water Reactor Dry Cask Simulator.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Durbin, Samuel; Lindgren, Eric R.
The thermal performance of commercial nuclear spent fuel dry storage casks is evaluated through detailed numerical analysis. These modeling efforts are completed by the vendor to demonstrate performance and regulatory compliance. The calculations are then independently verified by the Nuclear Regulatory Commission (NRC). Carefully measured data sets generated from testing of full sized casks or smaller cask analogs are widely recognized as vital for validating these models. Recent advances in dry storage cask designs have significantly increased the maximum thermal load allowed in a cask in part by increasing the efficiency of internal conduction pathways and by increasing the internalmore » convection through greater canister helium pressure. These same canistered cask systems rely on ventilation between the canister and the overpack to convect heat away from the canister to the environment for both aboveground and belowground configurations. While several testing programs have been previously conducted, these earlier validation attempts did not capture the effects of elevated helium pressures or accurately portray the external convection of aboveground and belowground canistered dry cask systems. The purpose of this investigation was to produce validation-quality data that can be used to test the validity of the modeling presently used to determine cladding temperatures in modern vertical dry casks. These cladding temperatures are critical to evaluate cladding integrity throughout the storage cycle. To produce these data sets under well-controlled boundary conditions, the dry cask simulator (DCS) was built to study the thermal-hydraulic response of fuel under a variety of heat loads, internal vessel pressures, and external configurations. An existing electrically heated but otherwise prototypic BWR Incoloy-clad test assembly was deployed inside of a representative storage basket and cylindrical pressure vessel that represents a vertical canister system. The symmetric single assembly geometry with well-controlled boundary conditions simplified interpretation of results. Two different arrangements of ducting were used to mimic conditions for aboveground and belowground storage configurations for vertical, dry cask systems with canisters. Transverse and axial temperature profiles were measured throughout the test assembly. The induced air mass flow rate was measured for both the aboveground and belowground configurations. In addition, the impact of cross-wind conditions on the belowground configuration was quantified. Over 40 unique data sets were collected and analyzed for these efforts. Fourteen data sets for the aboveground configuration were recorded for powers and internal pressures ranging from 0.5 to 5.0 kW and 0.3 to 800 kPa absolute, respectively. Similarly, fourteen data sets were logged for the belowground configuration starting at ambient conditions and concluding with thermal-hydraulic steady state. Over thirteen tests were conducted using a custom-built wind machine. The results documented in this report highlight a small, but representative, subset of the available data from this test series. This addition to the dry cask experimental database signifies a substantial addition of first-of-a-kind, high-fidelity transient and steady-state thermal-hydraulic data sets suitable for CFD model validation.« less
ERIC Educational Resources Information Center
Fisk, George; Nehmadi, David
A system has been developed to identify, locate and evaluate learning materials for use in an external degree program in management at Syracuse University. It consists of five elements, each of which is a set of physical objects or documents: the interaction of these sets transforms the demand for learning materials into an output of retrieved…
Giofrè, Fabrizio; Ferrari, Paola; Leidi, Cristina; Foschi, Maria Laura; Senni, Michele; De Filippo, Paolo
2017-08-15
In the first 24h after pacemaker or implantable cardioverter/defibrillator (ICD) implantation or replacement, the occurrence of hematoma and pain in the surgically treated region is not infrequent and may result in re-intervention and/or more severe complications, such as infections. Currently, the post-implant phase management is very empiric. The aim of this study was to test the clinical applicability and usefulness of an external close-circuit cooling system for the management of the early post-implant period in patients with high risk of hematoma due to anticoagulant and/or antiplatelet therapy. We studied 135 patients (78M; 71±11years) with high risk of hematoma occurrence after pace-maker (63 patients) or ICD (72 patients) implantation or replacement. Immediately after the intervention, a closed-circuit cooling system (CAREPACE™ system, Zamar, Italy) was externally applied on the pre-pectoral region to each patient and maintained for 24h. The system has a compressive pad and a refrigerating circuit in which non-toxic glycolic fluid is pumped. The fluid temperature was set and kept at 5°C for the whole period. The compressive and cooling effect of the system was well tolerated by all the patients at the temperature set. Four patients complained of noise due to machine operation, but in none the treatment was interrupted. The average length of hospital stay was 2.8±0.4days. No clinically significant hematoma was observed at discharge and after one month follow-up visit. This new system can be used for the management of the early phase after device implantation or replacement and appears clinically useful and well tolerated. Further studies on a larger scale are needed to test the potential reduction of post-intervention complications and the cost-effectiveness of this device. Copyright © 2017 Elsevier B.V. All rights reserved.
Bauer, S; Gusev, B I; Pivina, L M; Apsalikov, K N; Grosche, B
2006-01-01
This paper describes the Semipalatinsk historical cohort study and, in particular, examines the association between combined external and internal radiation exposure and esophagus cancer. Esophagus cancer is the most frequent single cancer site in the cause of death follow-up for the Semipalatinsk cohort. Set up in the 1960s, this historical cohort included 10 exposed settlements in the vicinity of the Semipalatinsk nuclear test site in East Kazakhstan as well as 6 comparison settlements in a low exposure area of the same region. The external and internal radiation doses to the population of the settlements under study were mainly due to local fallout from atmospheric nuclear testing (1949-1962). The database includes dosimetry and health information for 19.545 inhabitants of exposed and comparison villages in the Semipalatinsk region, comprising a total of 582.750 person-years of follow-up between 1960 and 1999. Cumulative effective dose estimates in this cohort range from 20 mSv to -4 Sv, with a mean dose of 634 mSv in the exposed group. Relative risks were calculated in terms of rate ratios, using a Poisson regression model for grouped person-time data. Esophagus cancer was found substantially elevated, with a statistically significant increase of the relative risk with dose and an ERR/Sv of 2.37 (1.45; 3.28) for the total cohort. If the data set was restricted to the exposed group only, the ERR/Sv was found considerably lower (0.18 (-0.16; 0.52)), whereas the dose-response remained significant only in women. Overall, our results based on the Semipalatinsk historical cohort indicate an association between fallout exposure and the risk of esophagus cancer that should be further investigated.
Sadeque, Farig; Xu, Dongfang; Bethard, Steven
2017-01-01
The 2017 CLEF eRisk pilot task focuses on automatically detecting depression as early as possible from a users’ posts to Reddit. In this paper we present the techniques employed for the University of Arizona team’s participation in this early risk detection shared task. We leveraged external information beyond the small training set, including a preexisting depression lexicon and concepts from the Unified Medical Language System as features. For prediction, we used both sequential (recurrent neural network) and non-sequential (support vector machine) models. Our models perform decently on the test data, and the recurrent neural models perform better than the non-sequential support vector machines while using the same feature sets. PMID:29075167
Molecular Docking Study on Galantamine Derivatives as Cholinesterase Inhibitors.
Atanasova, Mariyana; Yordanov, Nikola; Dimitrov, Ivan; Berkov, Strahil; Doytchinova, Irini
2015-06-01
A training set of 22 synthetic galantamine derivatives binding to acetylcholinesterase was docked by GOLD and the protocol was optimized in terms of scoring function, rigidity/flexibility of the binding site, presence/absence of a water molecule inside and radius of the binding site. A moderate correlation was found between the affinities of compounds expressed as pIC50 values and their docking scores. The optimized docking protocol was validated by an external test set of 11 natural galantamine derivatives and the correlation coefficient between the docking scores and the pIC50 values was 0.800. The derived relationship was used to analyze the interactions between galantamine derivatives and AChE. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Conducting meta-analyses of HIV prevention literatures from a theory-testing perspective.
Marsh, K L; Johnson, B T; Carey, M P
2001-09-01
Using illustrations from HIV prevention research, the current article advocates approaching meta-analysis as a theory-testing scientific method rather than as merely a set of rules for quantitative analysis. Like other scientific methods, meta-analysis has central concerns with internal, external, and construct validity. The focus of a meta-analysis should only rarely be merely describing the effects of health promotion, but rather should be on understanding and explaining phenomena and the processes underlying them. The methodological decisions meta-analysts make in conducting reviews should be guided by a consideration of the underlying goals of the review (e.g., simply effect size estimation or, preferably theory testing). From the advocated perspective that a health behavior meta-analyst should test theory, the authors present a number of issues to be considered during the conduct of meta-analyses.
NASA Technical Reports Server (NTRS)
Richey, Albert E.; Huang, Shyan-Cherng
1987-01-01
The testing of a prototype of an automotive Stirling engine, the Mod II, is discussed. The Mod II is a one-piece cast block with a V-4 single-crankshaft configuration and an annular regenerator/cooler design. The initial testing of Mod II concentrated on the basic engine, with auxiliaries driven by power sources external to the engine. The performance of the engine was tested at 720 C set temperature and 820 C tube temperature. At 720 C, it is observed that the power deficiency is speed dependent and linear, with a weak pressure dependency, and at 820 C, the power deficiency is speed and pressure dependent. The effects of buoyancy and nozzle spray pattern on the heater temperature spread are investigated. The characterization of the oil pump and the operating cycle and temperature spread tests are proposed for further evaluation of the engine.
On-board computer progress in development of A 310 flight testing program
NASA Technical Reports Server (NTRS)
Reau, P.
1981-01-01
Onboard computer progress in development of an Airbus A 310 flight testing program is described. Minicomputers were installed onboard three A 310 airplanes in 1979 in order to: (1) assure the flight safety by exercising a limit check of a given set of parameters; (2) improve the efficiency of flight tests and allow cost reduction; and (3) perform test analysis on an external basis by utilizing onboard flight types. The following program considerations are discussed: (1) conclusions based on simulation of an onboard computer system; (2) brief descriptions of A 310 airborne computer equipment, specifically the onboard universal calculator (CUB) consisting of a ROLM 1666 system and visualization system using an AFIGRAF CRT; (3) the ground system and flight information inputs; and (4) specifications and execution priorities for temporary and permanent programs.
Buckling of Thin Cylindrical Shell Subject to Uniform External Pressure
DOE Office of Scientific and Technical Information (OSTI.GOV)
Forasassi, G.; Lo Frano, R.
2006-07-01
The buckling of cylindrical shells under uniform external pressure loading has been widely investigated. In general, when tubes are subjected to external pressure, collapse is initiated by yielding, but interaction with instability is significant, in that imperfections associated with fabrication of shells reduce the load bearing capacity by a significant amount even when thickness is considerable. A specific buckling analysis is used to predict collapse failure of long pressure vessels and pipelines when they are subjected to external over-pressure. The problem of buckling for variable load conditions is relevant for the optimisation of several Nuclear Power Plant applications as, formore » instance, the IRIS (International Reactor Innovative and Secure) LWR integrated Steam Generator (SG) tubes. In this paper, we consider in addition to the usual assumptions of thin shell, homogeneous and isotropic material, also the tube geometric imperfections and plastic deformations that may affect the limit load. When all those conditions are considered at present, a complete theoretical analysis was not founding the literature. At Pisa University a research activity is being carried out on the buckling of thin walled metal specimen, with reference to several geometries and two different stainless steel materials. A test equipment (with the necessary data acquisition facility), suitable for carrying out many test on this issue, as well as numerical models implemented on the MARC FEM code, were set up. In this report, the results of the performed analyses of critical pressure load determination with different numerical and experimental approaches are presented. The numerical results obtained are compared with the experimental results, for the same geometry and loading conditions, showing a good agreement between these two approaches. (authors)« less
Risk factors associated with exertional medial tibial pain: a 12 month prospective clinical study
Burne, S; Khan, K; Boudville, P; Mallet, R; Newman, P; Steinman, L; Thornton, E
2004-01-01
Objective: To investigate in a military setting the potential role of intrinsic biomechanical and anthropometric risk factors for, and the incidence of, exertional medial tibial pain (EMTP). Methods: A prospective clinical outcome study in a cohort of 122 men and 36 women at the Australian Defence Force Academy. Each cadet underwent measurements of seven intrinsic variables: hip range of motion, leg length discrepancy, lean calf girth, maximum ankle dorsiflexion range, foot type, rear foot alignment, and tibial alignment. Test–retest reliability was undertaken on each variable. A physician recorded any cadet presenting with diagnostic criteria of EMTP. Records were analysed at 12 months for EMTP presentation and for military fitness test results. Results: 23 cadets (12 men, 11 women) met the criteria for EMTP after 12 months, with a cross gender (F/M) odds ratio of 3.1. In men, both internal and external range of hip motion was greater in those with EMTP: left internal (12°, p = 0.000), right internal (8°, p = 0.014), left external (8°, p = 0.042), right external (9°, p = 0.026). Lean calf girth was lower by 4.2% for the right leg (p = 0.040) but by only 2.9% for the left leg (p = 0.141). No intrinsic risk factor was associated with EMTP in women. EMTP was the major cause for non-completion of the run component of the ADFA fitness test in both men and women. Conclusions: Greater internal and external hip range of motion and lower lean calf girth were associated with EMTP in male military cadets. Women had high rates of injury, although no intrinsic factor was identified. Reasons for this sex difference need to be identified. PMID:15273181
NASA Technical Reports Server (NTRS)
Konoplev, Oleg A.; Chiragh, Furqan L.; Vasilyev, Aleksey A.; Edwards, Ryan; Stephen, Mark A.; Troupaki, Elisavet; Yu, Anthony W.; Krainak, Michael A.; Sawruk, Nick; Hovis, Floyd;
2016-01-01
We present the results of three year life-aging of a specially designed prototype flight source laser operating at 1064 nm, 10 kHz, 1ns, 15W average power and external frequency doubler. The Fibertek-designed, slightly pressurized air, enclosed-container source laser operated at 1064 nm in active Q-switching mode. The external frequency doubler was set in a clean room at a normal air pressure. The goal of the experiment was to measure degradation modes at 1064 and 532 nm discreetly. The external frequency doubler consisted of a Lithium triborate, LiB3O5, crystal operated at non-critical phase-matching. Due to 1064 nm diagnostic needs, the amount of fundamental frequency power available for doubling was 13.7W. The power generated at 532 nm was between 8.5W and 10W, depending on the level of stress and degradation. The life-aging consisted of double stress-step operation for doubler crystal, at 0.35 J/cm2 for almost 1 year, corresponding to normal conditions, and then at 0.93 J/cm2 for the rest of the experiment, corresponding to accelerated testing. We observed no degradation at the first step and linear degradation at the second step. The linear degradation at the second stress-step was related to doubler crystal output surface changes and linked to laser-assisted contamination. We discuss degradation model and estimate the expected lifetime for the flight laser at 532 nm. This work was done within the laser testing for NASA's Ice, Cloud, and land Elevation Satellite-2 (ICESat-2) LIDAR at Goddard Space Flight Center in Greenbelt, MD with the goal of 1 trillion shots lifetime.
NASA Technical Reports Server (NTRS)
Konoplev, Oleg A.; Chiragh, Furqan L.; Vasilyev, Aleksey A.; Edwards, Ryan; Stephen, Mark A.; Troupaki, Elisavet; Yu, Anthony W.; Krainak, Michael A.; Sawruk, Nick; Hovis, Floyd;
2016-01-01
We present the results of three year life-aging of a specially designed prototype flight source laser operating at 1064 nm, 10 kHz, 1ns, 15W average power and external frequency doubler. The Fibertek-designed, slightly pressurized air, enclosed-container source laser operated at 1064 nm in active Q-switching mode. The external frequency doubler was set in a clean room at a normal air pressure. The goal of the experiment was to measure degradation modes at 1064 and 532 nm discreetly. The external frequency doubler consisted of a Lithium triborate, LiB3O5, crystal operated at non-critical phase-matching. Due to 1064 nm diagnostic needs, the amount of fundamental frequency power available for doubling was 13.7W. The power generated at 532 nm was between 8.5W and 10W, depending on the level of stress and degradation. The life-aging consisted of double stress-step operation for doubler crystal, at 0.35 Jcm2 for almost 1 year, corresponding to normal conditions, and then at 0.93 Jcm2 for the rest of the experiment, corresponding to accelerated testing. We observed no degradation at the first step and linear degradation at the second step. The linear degradation at the second stress-step was related to doubler crystal output surface changes and linked to laser-assisted contamination. We discuss degradation model and estimate the expected lifetime for the flight laser at 532 nm. This work was done within the laser testing for NASAs Ice, Cloud, and land Elevation Satellite-2 (ICESat-2) LIDAR at Goddard Space Flight Center in Greenbelt, MD with the goal of 1 trillion shots lifetime.
Safety of externally stimulated intracranial electrodes during functional MRI at 1.5T.
Bhattacharyya, Pallab K; Mullin, Jeffery; Lee, Bryan S; Gonzalez-Martinez, Jorge A; Jones, Stephen E
2017-05-01
Surgical resection of the epileptogenic zone (EZ) is a potential cure for medically refractory focal epilepsy. Proper identification of the EZ is essential for such resection. Synergistic application of functional magnetic resonance imaging (fMRI) simultaneously with stimulation of a single externalized intracranial stereotactic EEG (SEEG) electrode has the potential to improve identification of the EZ. While most EEG-fMRI studies use the electrodes passively to record electrical activity, it is possible to stimulate the brain using the electrodes by connecting them with conducting cables to the stimulation hardware. In this study, we investigated the effect of MRI-induced heating on a single SEEG electrode and its sensitivity to geometry, configuration, and associated connections required for the stimulation. The temperature increase of a single electrode embedded within a gel phantom and connected to an external stimulation system was measured during 1.5T MRI scans using adjacent fluoroptic temperature sensors. A receive-only split-array head coil and a transmit-receive head coil were used for testing. Sequences included a standard localizer, T1-weighted axial fast low-angle shot (FLASH), gradient echo-planar imaging (GE-EPI) axial fMRI, and a high specific absorption rate T2-weighted turbo spin-echo (TSE) axial scan. Variations of the electrode location and connecting cable configuration were tested. No unacceptable heating was observed with the standard sequences used for evaluation of the EZ. Considerable heating (up to 14°C) was observed with the TSE sequence, which is not used clinically. The temperature increase was insignificant (<0.05°C) for electrode contacts closest to the isocenter and connecting cables lying along the isocenter, and varied with configurations of the connecting cable assembly. Simultaneous intracranial electrode stimulation during fMRI using an externalized stimulation system may be safe with strict adherence to settings tested prior to the fMRI. Localizer, FLASH, and GE-EPI fMRI may be safely performed in patients with a single SEEG electrode following the configurations tested in this study, but high SAR TSE scans should not be performed in these patients. Copyright © 2017 Elsevier Inc. All rights reserved.
Artificial neural network classifier predicts neuroblastoma patients' outcome.
Cangelosi, Davide; Pelassa, Simone; Morini, Martina; Conte, Massimo; Bosco, Maria Carla; Eva, Alessandra; Sementa, Angela Rita; Varesio, Luigi
2016-11-08
More than fifty percent of neuroblastoma (NB) patients with adverse prognosis do not benefit from treatment making the identification of new potential targets mandatory. Hypoxia is a condition of low oxygen tension, occurring in poorly vascularized tissues, which activates specific genes and contributes to the acquisition of the tumor aggressive phenotype. We defined a gene expression signature (NB-hypo), which measures the hypoxic status of the neuroblastoma tumor. We aimed at developing a classifier predicting neuroblastoma patients' outcome based on the assessment of the adverse effects of tumor hypoxia on the progression of the disease. Multi-layer perceptron (MLP) was trained on the expression values of the 62 probe sets constituting NB-hypo signature to develop a predictive model for neuroblastoma patients' outcome. We utilized the expression data of 100 tumors in a leave-one-out analysis to select and construct the classifier and the expression data of the remaining 82 tumors to test the classifier performance in an external dataset. We utilized the Gene set enrichment analysis (GSEA) to evaluate the enrichment of hypoxia related gene sets in patients predicted with "Poor" or "Good" outcome. We utilized the expression of the 62 probe sets of the NB-Hypo signature in 182 neuroblastoma tumors to develop a MLP classifier predicting patients' outcome (NB-hypo classifier). We trained and validated the classifier in a leave-one-out cross-validation analysis on 100 tumor gene expression profiles. We externally tested the resulting NB-hypo classifier on an independent 82 tumors' set. The NB-hypo classifier predicted the patients' outcome with the remarkable accuracy of 87 %. NB-hypo classifier prediction resulted in 2 % classification error when applied to clinically defined low-intermediate risk neuroblastoma patients. The prediction was 100 % accurate in assessing the death of five low/intermediated risk patients. GSEA of tumor gene expression profile demonstrated the hypoxic status of the tumor in patients with poor prognosis. We developed a robust classifier predicting neuroblastoma patients' outcome with a very low error rate and we provided independent evidence that the poor outcome patients had hypoxic tumors, supporting the potential of using hypoxia as target for neuroblastoma treatment.
Quality Improvement Intervention for Reduction of Redundant Testing.
Ducatman, Alan M; Tacker, Danyel H; Ducatman, Barbara S; Long, Dustin; Perrotta, Peter L; Lawther, Hannah; Pennington, Kelly; Lander, Owen; Warden, Mary; Failinger, Conard; Halbritter, Kevin; Pellegrino, Ronald; Treese, Marney; Stead, Jeffrey A; Glass, Eric; Cianciaruso, Lauren; Nau, Konrad C
2017-01-01
Laboratory data are critical to analyzing and improving clinical quality. In the setting of residual use of creatine kinase M and B isoenzyme testing for myocardial infarction, we assessed disease outcomes of discordant creatine kinase M and B isoenzyme +/troponin I (-) test pairs in order to address anticipated clinician concerns about potential loss of case-finding sensitivity following proposed discontinuation of routine creatine kinase and creatine kinase M and B isoenzyme testing. Time-sequenced interventions were introduced. The main outcome was the percentage of cardiac marker studies performed within guidelines. Nonguideline orders dominated at baseline. Creatine kinase M and B isoenzyme testing in 7496 order sets failed to detect additional myocardial infarctions but was associated with 42 potentially preventable admissions/quarter. Interruptive computerized soft stops improved guideline compliance from 32.3% to 58% ( P < .001) in services not receiving peer leader intervention and to >80% ( P < .001) with peer leadership that featured dashboard feedback about test order performance. This successful experience was recapitulated in interrupted time series within 2 additional services within facility 1 and then in 2 external hospitals (including a critical access facility). Improvements have been sustained postintervention. Laboratory cost savings at the academic facility were estimated to be ≥US$635 000 per year. National collaborative data indicated that facility 1 improved its order patterns from fourth to first quartile compared to peer norms and imply that nonguideline orders persist elsewhere. This example illustrates how pathologists can provide leadership in assisting clinicians in changing laboratory ordering practices. We found that clinicians respond to local laboratory data about their own test performance and that evidence suggesting harm is more compelling to clinicians than evidence of cost savings. Our experience indicates that interventions done at an academic facility can be readily instituted by private practitioners at external facilities. The intervention data also supplement existing literature that electronic order interruptions are more successful when combined with modalities that rely on peer education combined with dashboard feedback about laboratory order performance. The findings may have implications for the role of the pathology laboratory in the ongoing pivot from quantity-based to value-based health care.
Relations between Internalizing and Externalizing Problems in Early Childhood
ERIC Educational Resources Information Center
Stone, Lisanne L.; Otten, Roy; Engels, Rutger C. M. E.; Kuijpers, Rowella C. W. M.; Janssens, Jan M. A. M.
2015-01-01
Background: Childhood internalizing and externalizing problems are closely related and often co-occur. Directional models have been employed to test how these problems are related, while few studies have tested a third variables model. Objective: This study investigates whether internalizing and externalizing problems are reciprocally or…
NASA Astrophysics Data System (ADS)
Jacobs, James Patrick
Optically pumped atomic oscillators driven with a modulated light source have been used to measure the Permanent Electric Dipole Moment (PEDM) of the ^{199}Hg atom. A nonzero PEDM on the ground state of ^{199} Hg would be a direct violation of time reversal symmetry. The measurement was obtained by searching for a relative shift in the resonance frequency of the processing nuclear magnetic moments when an externally applied electric field was reversed relative to an externally applied magnetic field. The null result, d(^{199} Hg) = (.3 +/- 5.7 +/- 5.0) times 10 ^{-28} ecdotcm, represents nearly a factor of 15 improvement over previous ^{199}Hg measurements, and a factor of 25 improvement in statistical uncertainty. When combined with theoretical calculations, the result sets stringent limits on possible sources of time reversal symmetry violation in atomic systems.
Spinrad, Tracy L.; Eisenberg, Nancy; Gaertner, Bridget; Popp, Tierney; Smith, Cynthia L.; Kupfer, Anne; Greving, Karissa; Liew, Jeffrey; Hofer, Claire
2007-01-01
The authors examined the relations of maternal supportive parenting to effortful control and internalizing problems (i.e., separation distress, inhibition to novelty), externalizing problems, and social competence when toddlers were 18 months old (n = 256) and a year later (n = 230). Mothers completed the Coping With Toddlers' Negative Emotions Scale, and their sensitivity and warmth were observed. Toddlers' effortful control was measured with a delay task and adults' reports (Early Childhood Behavior Questionnaire). Toddlers' social functioning was assessed with the Infant/Toddler Social and Emotional Assessment. Within each age, children's regulation significantly mediated the relation between supportive parenting and low levels of externalizing problems and separation distress, and high social competence. When using stronger tests of mediation, controlling for stability over time, the authors found only partial evidence for mediation. The findings suggest these relations may be set at an early age. PMID:17723043
Van der Ende, Jan; Verhulst, Frank C; Tiemeier, Henning
2016-08-01
Internalizing and externalizing problems are associated with poor academic performance, both concurrently and longitudinally. Important questions are whether problems precede academic performance or vice versa, whether both internalizing and externalizing are associated with academic problems when simultaneously tested, and whether associations and their direction depend on the informant providing information. These questions were addressed in a sample of 816 children who were assessed four times. The children were 6-10 years at baseline and 14-18 years at the last assessment. Parent-reported internalizing and externalizing problems and teacher-reported academic performance were tested in cross-lagged models to examine bidirectional paths between these constructs. These models were compared with cross-lagged models testing paths between teacher-reported internalizing and externalizing problems and parent-reported academic performance. Both final models revealed similar pathways from mostly externalizing problems to academic performance. No paths emerged from internalizing problems to academic performance. Moreover, paths from academic performance to internalizing and externalizing problems were only found when teachers reported on children's problems and not for parent-reported problems. Additional model tests revealed that paths were observed in both childhood and adolescence. Externalizing problems place children at increased risk of poor academic performance and should therefore be the target for interventions.
A Managerial Approach to Compensation
ERIC Educational Resources Information Center
Wolfe, Arthur V.
1975-01-01
The article examines the major external forces constraining equitable employee compensation, sets forth the classical employee compensation assumptions, suggests somewhat more realistic employee compensation assumptions, and proposes guidelines based on analysis of these external constraints and assumptions. (Author)
Effect of workload setting on propulsion technique in handrim wheelchair propulsion.
van Drongelen, Stefan; Arnet, Ursina; Veeger, Dirkjan H E J; van der Woude, Lucas H V
2013-03-01
To investigate the influence of workload setting (speed at constant power, method to impose power) on the propulsion technique (i.e. force and timing characteristics) in handrim wheelchair propulsion. Twelve able-bodied men participated in this study. External forces were measured during handrim wheelchair propulsion on a motor driven treadmill at different velocities and constant power output (to test the forced effect of speed) and at power outputs imposed by incline vs. pulley system (to test the effect of method to impose power). Outcome measures were the force and timing variables of the propulsion technique. FEF and timing variables showed significant differences between the speed conditions when propelling at the same power output (p < 0.01). Push time was reduced while push angle increased. The method to impose power only showed slight differences in the timing variables, however not in the force variables. Researchers and clinicians must be aware of testing and evaluation conditions that may differently affect propulsion technique parameters despite an overall constant power output. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.
49 CFR 173.58 - Assignment of class and division for new explosives.
Code of Federal Regulations, 2011 CFR
2011-10-01
....4 explosives. In addition to the test prescribed in § 173.57 of this subchapter, a substance or... tests: Cap Sensitivity Test, Princess Incendiary Spark Test, DDT Test, and External Fire Test, each as... projection of fragments, occurs in the External Fire Test (Test Method 5(c), or (4) Ignition or explosion...
49 CFR 173.58 - Assignment of class and division for new explosives.
Code of Federal Regulations, 2012 CFR
2012-10-01
....4 explosives. In addition to the test prescribed in § 173.57 of this subchapter, a substance or... tests: Cap Sensitivity Test, Princess Incendiary Spark Test, DDT Test, and External Fire Test, each as... projection of fragments, occurs in the External Fire Test (Test Method 5(c), or (4) Ignition or explosion...
49 CFR 173.58 - Assignment of class and division for new explosives.
Code of Federal Regulations, 2014 CFR
2014-10-01
....4 explosives. In addition to the test prescribed in § 173.57 of this subchapter, a substance or... tests: Cap Sensitivity Test, Princess Incendiary Spark Test, DDT Test, and External Fire Test, each as... projection of fragments, occurs in the External Fire Test (Test Method 5(c), or (4) Ignition or explosion...
49 CFR 173.58 - Assignment of class and division for new explosives.
Code of Federal Regulations, 2013 CFR
2013-10-01
....4 explosives. In addition to the test prescribed in § 173.57 of this subchapter, a substance or... tests: Cap Sensitivity Test, Princess Incendiary Spark Test, DDT Test, and External Fire Test, each as... projection of fragments, occurs in the External Fire Test (Test Method 5(c), or (4) Ignition or explosion...
Predicting a small molecule-kinase interaction map: A machine learning approach
2011-01-01
Background We present a machine learning approach to the problem of protein ligand interaction prediction. We focus on a set of binding data obtained from 113 different protein kinases and 20 inhibitors. It was attained through ATP site-dependent binding competition assays and constitutes the first available dataset of this kind. We extract information about the investigated molecules from various data sources to obtain an informative set of features. Results A Support Vector Machine (SVM) as well as a decision tree algorithm (C5/See5) is used to learn models based on the available features which in turn can be used for the classification of new kinase-inhibitor pair test instances. We evaluate our approach using different feature sets and parameter settings for the employed classifiers. Moreover, the paper introduces a new way of evaluating predictions in such a setting, where different amounts of information about the binding partners can be assumed to be available for training. Results on an external test set are also provided. Conclusions In most of the cases, the presented approach clearly outperforms the baseline methods used for comparison. Experimental results indicate that the applied machine learning methods are able to detect a signal in the data and predict binding affinity to some extent. For SVMs, the binding prediction can be improved significantly by using features that describe the active site of a kinase. For C5, besides diversity in the feature set, alignment scores of conserved regions turned out to be very useful. PMID:21708012
Stegman, Kelly J; Park, Edward J; Dechev, Nikolai
2012-07-01
The motivation of this research is to non-invasively monitor the wrist tendon's displacement and velocity, for purposes of controlling a prosthetic device. This feasibility study aims to determine if the proposed technique using Doppler ultrasound is able to accurately estimate the tendon's instantaneous velocity and displacement. This study is conducted with a tendon mimicking experiment consisting of two different materials: a commercial ultrasound scanner, and a reference linear motion stage set-up. Audio-based output signals are acquired from the ultrasound scanner, and are processed with our proposed Fourier technique to obtain the tendon's velocity and displacement estimates. We then compare our estimates to an external reference system, and also to the ultrasound scanner's own estimates based on its proprietary software. The proposed tendon motion estimation method has been shown to be repeatable, effective and accurate in comparison to the external reference system, and is generally more accurate than the scanner's own estimates. After establishing this feasibility study, future testing will include cadaver-based studies to test the technique on the human arm tendon anatomy, and later on live human test subjects in order to further refine the proposed method for the novel purpose of detecting user-intended tendon motion for controlling wearable prosthetic devices.
Effects of Deployment on Musculoskeletal and Physiological Characteristics and Balance.
Nagai, Takashi; Abt, John P; Sell, Timothy C; Keenan, Karen A; McGrail, Mark A; Smalley, Brian W; Lephart, Scott M
2016-09-01
Despite many nonbattle injuries reported during deployment, few studies have been conducted to evaluate the effects of deployment on musculoskeletal and physiological characteristics and balance. A total of 35 active duty U.S. Army Soldiers participated in laboratory testing before and after deployment to Afghanistan. The following measures were obtained for each Soldier: shoulder, trunk, hip, knee, and ankle strength and range of motion (ROM), balance, body composition, aerobic capacity, and anaerobic power/capacity. Additionally, Soldiers were asked about their physical activity and load carriage. Paired t tests or Wilcoxon tests with an α = 0.05 set a priori were used for statistical analyses. Shoulder external rotation ROM, torso rotation ROM, ankle dorsiflexion ROM, torso rotation strength, and anaerobic power significantly increased following deployment (p < 0.05). Shoulder extension ROM, shoulder external rotation strength, and eyes-closed balance (p < 0.05) were significantly worse following deployment. The majority of Soldiers (85%) engaged in physical activity. In addition, 58% of Soldiers reported regularly carrying a load (22 kg average). The deployment-related changes in musculoskeletal and physiological characteristics and balance as well as physical activity and load carriage during deployment may assist with proper preparation with the intent to optimize tactical readiness and mitigate injury risk. Reprint & Copyright © 2016 Association of Military Surgeons of the U.S.
Classification and virtual screening of androgen receptor antagonists.
Li, Jiazhong; Gramatica, Paola
2010-05-24
Computational tools, such as quantitative structure-activity relationship (QSAR), are highly useful as screening support for prioritization of substances of very high concern (SVHC). From the practical point of view, QSAR models should be effective to pick out more active rather than inactive compounds, expressed as sensitivity in classification works. This research investigates the classification of a big data set of endocrine-disrupting chemicals (EDCs)-androgen receptor (AR) antagonists, mainly aiming to improve the external sensitivity and to screen for potential AR binders. The kNN, lazy IB1, and ADTree methods and the consensus approach were used to build different models, which improve the sensitivity on external chemicals from 57.1% (literature) to 76.4%. Additionally, the models' predictive abilities were further validated on a blind collected data set (sensitivity: 85.7%). Then the proposed classifiers were used: (i) to distinguish a set of AR binders into antagonists and agonists; (ii) to screen a combined estrogen receptor binder database to find out possible chemicals that can bind to both AR and ER; and (iii) to virtually screen our in-house environmental chemical database. The in silico screening results suggest: (i) that some compounds can affect the normal endocrine system through a complex mechanism binding both to ER and AR; (ii) new EDCs, which are nonER binders, but can in silico bind to AR, are recognized; and (iii) about 20% of compounds in a big data set of environmental chemicals are predicted as new AR antagonists. The priority should be given to them to experimentally test the binding activities with AR.
Tensile testing grips ensure uniform loading of bimetal tubing specimens
NASA Technical Reports Server (NTRS)
Driscol, S. D.; Hunt, V.
1968-01-01
Tensile testing grip uniformly distributes stresses to the internal and external tube of bimetal tubing specimens. The grip is comprised of a slotted external tube grip, a slotted internal tube grip, a machine bolt and nut, an internal grip expansion cone, and an external grip compression nut.
Schooling and National Income: How Large Are the Externalities?
ERIC Educational Resources Information Center
Breton, Theodore R.
2010-01-01
This paper uses a new data-set for cumulative national investment in formal schooling and a new instrument for schooling to estimate the national return on investment in 61 countries. These estimates are combined with data on the private rate of return on investment in schooling to estimate the external rate of return. In 1990 the external rate of…
49 CFR 173.58 - Assignment of class and division for new explosives.
Code of Federal Regulations, 2010 CFR
2010-10-01
....4 explosives. In addition to the test prescribed in § 173.57 of this subchapter, a substance or... Sensitivity Test, Princess Incendiary Spark Test, DDT Test, and External Fire Test, each as described in the... fragments, occurs in the External Fire Test (Test Method 5(c), or (4) Ignition or explosion occurs in the...
1993-01-01
external parameters such as airflow, temperature, pressure, etc, are measured. Turbine Engine testing generates massive volumes of data at very high...a form that describes the signal flow graph topology as well as specific parameters of the processing blocks in the diagram. On multiprocessor...provides an interface to the symbolic builder and control functions such that parameters may be set during the build operation that will affect the
Street, Brian D; Gage, William
2013-04-01
The external knee adduction moment is an accurate estimation of the load distribution of the knee and is a valid predictor for the presence, severity and progression rate of medial compartment knee osteoarthritis. Gait modification strategies have been shown to be an effective means of reducing the external adduction moment. The purpose of this study was to test narrow gait as a mechanism to reduce the external adduction moment and investigate if limb dominance affects this pattern. Fifteen healthy male participants (mean age: 23.8 (SD=3.1) years, mean height: 1.8 (SD=0.1) m, and mean body mass: 82.9 (SD=16.1 kg) took part in this study. Five walking trials were performed for each of the three different gait conditions: normal gait, toe-out gait, and narrow gait. Adoption of the narrow gait strategy significantly reduced the early stance phase external knee adduction moment compared to normal and toe-out gait (p<.002). However, it was observed that this reduction only occurred in the non-dominant limb. Gait modification can reduce the external knee adduction moment. However, asymmetrical patterns between the dominant and non-dominant limbs, specifically during gait modification, may attenuate the effectiveness of this intervention. The mechanism of limb dominance and the specific roles of each limb during gait may account for an asymmetrical pattern in the moment arm and center of mass displacement during stance. This new insight into how limb-dominance effects gait modification strategies will be useful in the clinical setting when identifying appropriate patients, when indicating a gait modification strategy and in future research methodology. Copyright © 2013 Elsevier B.V. All rights reserved.
Resonator modes and mode dynamics for an external cavity-coupled laser array
NASA Astrophysics Data System (ADS)
Nair, Niketh; Bochove, Erik J.; Aceves, Alejandro B.; Zunoubi, Mohammad R.; Braiman, Yehuda
2015-03-01
Employing a Fox-Li approach, we derived the cold-cavity mode structure and a coupled mode theory for a phased array of N single-transverse-mode active waveguides with feedback from an external cavity. We applied the analysis to a system with arbitrary laser lengths, external cavity design and coupling strengths to the external cavity. The entire system was treated as a single resonator. The effect of the external cavity was modeled by a set of boundary conditions expressed by an N-by-N frequency-dependent matrix relation between incident and reflected fields at the interface with the external cavity. The coupled mode theory can be adapted to various types of gain media and internal and external cavity designs.
PreFix™ external fixator used to treat a floating shoulder injury caused by gunshot wound.
Vogels, J; Pommier, N; Cursolle, J-C; Belin, C; Tournier, C; Durandeau, A
2014-10-01
Open fractures of the shoulder are extremely rare, and their treatment is a major challenge for surgeons. Only cases encountered in military settings have been reported thus far. Such fractures are often the result of ballistic trauma, which causes extensive damage to both bony and soft tissues. Since these injuries are associated with a high risk of infection and the presence of comminuted fractures, external fixation is necessary for repair. Use of external fixators and revascularization techniques has reduced the number of cases requiring shoulder amputation or disarticulation. Injury to the proximal extremity of the humerus, acromion, and clavicle further complicates the treatment. No published studies have described the assembly of external fixators for fractures in the scapular region with significant bone loss. In addition, no cases have been described in civilian settings. However, with an increase in urban violence and the traffic of illegal arms, civilian surgeons are now encountering an increasing number of patients with these injuries. In this report, we not only present a rare case of floating shoulder injury in a civilian setting but also provide an overview of the existing treatment strategies for this type of trauma, with special focus on the use of external fixators in elective shoulder arthrodesis and on military cases. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
Bajaj, Jasmohan S; Heuman, Douglas M; Sterling, Richard K; Sanyal, Arun J; Siddiqui, Muhammad; Matherly, Scott; Luketic, Velimir; Stravitz, R Todd; Fuchs, Michael; Thacker, Leroy R; Gilles, HoChong; White, Melanie B; Unser, Ariel; Hovermale, James; Gavis, Edith; Noble, Nicole A; Wade, James B
2015-10-01
Detection of covert hepatic encephalopathy (CHE) is difficult, but point-of-care testing could increase rates of diagnosis. We aimed to validate the ability of the smartphone app EncephalApp, a streamlined version of Stroop App, to detect CHE. We evaluated face validity, test-retest reliability, and external validity. Patients with cirrhosis (n = 167; 38% with overt HE [OHE]; mean age, 55 years; mean Model for End-Stage Liver Disease score, 12) and controls (n = 114) were each given a paper and pencil cognitive battery (standard) along with EncephalApp. EncephalApp has Off and On states; results measured were OffTime, OnTime, OffTime+OnTime, and number of runs required to complete 5 off and on runs. Thirty-six patients with cirrhosis underwent driving simulation tests, and EncephalApp results were correlated with results. Test-retest reliability was analyzed in a subgroup of patients. The test was performed before and after transjugular intrahepatic portosystemic shunt placement, and before and after correction for hyponatremia, to determine external validity. All patients with cirrhosis performed worse on paper and pencil and EncephalApp tests than controls. Patients with cirrhosis and OHE performed worse than those without OHE. Age-dependent EncephalApp cutoffs (younger or older than 45 years) were set. An OffTime+OnTime value of >190 seconds identified all patients with CHE with an area under the receiver operator characteristic value of 0.91; the area under the receiver operator characteristic value was 0.88 for diagnosis of CHE in those without OHE. EncephalApp times correlated with crashes and illegal turns in driving simulation tests. Test-retest reliability was high (intraclass coefficient, 0.83) among 30 patients retested 1-3 months apart. OffTime+OnTime increased significantly (206 vs 255 seconds, P = .007) among 10 patients retested 33 ± 7 days after transjugular intrahepatic portosystemic shunt placement. OffTime+OnTime decreased significantly (242 vs 225 seconds, P = .03) in 7 patients tested before and after correction for hyponatremia (126 ± 3 to 132 ± 4 meq/L, P = .01) 10 ± 5 days apart. A smartphone app called EncephalApp has good face validity, test-retest reliability, and external validity for the diagnosis of CHE. Copyright © 2015 AGA Institute. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Tahavori, Fatemeh
Respiratory motion induces uncertainty in External Beam Radiotherapy (EBRT), which can result in sub-optimal dose delivery to the target tissue and unwanted dose to normal tissue. The conventional approach to managing patient respiratory motion for EBRT within the area of abdominal-thoracic cancer is through the use of internal radiological imaging methods (e.g. Megavoltage imaging or Cone-Beam Computed Tomography) or via surrogate estimates of tumour position using external markers placed on the patient chest. This latter method uses tracking with video-based techniques, and relies on an assumed correlation or mathematical model, between the external surrogate signal and the internal target position. The marker's trajectory can be used in both respiratory gating techniques and real-time tracking methods. Internal radiological imaging methods bring with them limited temporal resolution, and additional radiation burden, which can be addressed by external marker-based methods that carry no such issues. Moreover, by including multiple external markers and placing them closer to the internal target organs, the effciency of correlation algorithms can be increased. However, the quality of such external monitoring methods is underpinned by the performance of the associated correlation model. Therefore, several new approaches to correlation modelling have been developed as part of this thesis and compared using publicly-available datasets. Highly competitive results have been obtained when compared against state-of-the-art methods. Marker-based methods also have the disadvantages of requiring manual set-up time for marker placement and patient positioning and potential issues with reproducibility of marker placement. This motivates the investigation of non-contact marker-free methods for use in EBRT, which is the main topic of this thesis. The Microsoft Kinect is used as an example of a low-cost consumer grade 3D depth camera for capturing and analysing external respiratory motion. This thesis makes the first presentation of detailed studies of external respiratory motion captured using such low-cost technology and demonstrates its potential in a healthcare environment. Firstly, the fundamental performance of a range of Microsoft Kinect sensors is assessed for use in radiotherapy (and potentially other healthcare applications), in terms of static and dynamic performance using both phantoms and volunteers. Then external respiratory motion is captured using the above technology from a group of 32 healthy volunteers and Principal Component Analysis (PCA) is applied to a region of interest encompassing the complete anterior surface to demonstrate breathing style. This work demonstrates that this surface motion can be compactly described by the first two PCA eigenvectors. The reproducibility of subject-specific EBRT set-up using conventional laser-based alignment and marker-based Deep Inspiration Breath Hold (DIBH) methods are also studied using the Microsoft Kinect sensor. A cohort of five healthy female volunteers is repeatedly set-up for left-sided breast cancer EBRT and multiple DIBH episodes captured over five separate sessions representing multiple fractionated radiotherapy treatment sessions, but without dose delivery. This provided an independent assessment that subjects were set-up and generally achieved variations within currently accepted margins of clinical practice. Moreover, this work demonstrated the potential role of consumer-grade 3D depth camera technology as a possible replacement for marker based set-up and DIBH management procedures. This brings with it the additional benefits of low cost, and potential through-put benefits, as patient set-up could ultimately be fully automated with this technology, and DIBH could be independently monitored without requiring preparatory manual intervention.
Towards non- and minimally instrumented, microfluidics-based diagnostic devices†
Weigl, Bernhard; Domingo, Gonzalo; LaBarre, Paul; Gerlach, Jay
2009-01-01
In many health care settings, it is uneconomical, impractical, or unaffordable to maintain and access a fully equipped diagnostics laboratory. Examples include home health care, developing-country health care, and emergency situations in which first responders are dealing with pandemics or biowarfare agent release. In those settings, fully disposable diagnostic devices that require no instrument support, reagent, or significant training are well suited. Although the only such technology to have found widespread adoption so far is the immunochromatographic rapid assay strip test, microfluidics holds promise to expand the range of assay technologies that can be performed in formats similar to that of a strip test. In this paper, we review progress toward development of disposable, low-cost, easy-to-use microfluidics-based diagnostics that require no instrument at all. We also present examples of microfluidic functional elements—including mixers, separators, and detectors—as well as complete microfluidic devices that function entirely without any moving parts and external power sources. PMID:19023463
Afantitis, Antreas; Melagraki, Georgia; Sarimveis, Haralambos; Koutentis, Panayiotis A; Igglessi-Markopoulou, Olga; Kollias, George
2010-05-01
A novel QSAR workflow is constructed that combines MLR with LS-SVM classification techniques for the identification of quinazolinone analogs as "active" or "non-active" CXCR3 antagonists. The accuracy of the LS-SVM classification technique for the training set and test was 100% and 90%, respectively. For the "active" analogs a validated MLR QSAR model estimates accurately their I-IP10 IC(50) inhibition values. The accuracy of the QSAR model (R (2) = 0.80) is illustrated using various evaluation techniques, such as leave-one-out procedure (R(LOO2)) = 0.67) and validation through an external test set (R(pred2) = 0.78). The key conclusion of this study is that the selected molecular descriptors, Highest Occupied Molecular Orbital energy (HOMO), Principal Moment of Inertia along X and Y axes PMIX and PMIZ, Polar Surface Area (PSA), Presence of triple bond (PTrplBnd), and Kier shape descriptor ((1) kappa), demonstrate discriminatory and pharmacophore abilities.
Wang, Yonghua; Li, Yan; Wang, Bin
2007-01-01
Nicotine and a variety of other drugs and toxins are metabolized by cytochrome P450 (CYP) 2A6. The aim of the present study was to build a quantitative structure-activity relationship (QSAR) model to predict the activities of nicotine analogues on CYP2A6. Kernel partial least squares (K-PLS) regression was employed with the electro-topological descriptors to build the computational models. Both the internal and external predictabilities of the models were evaluated with test sets to ensure their validity and reliability. As a comparison to K-PLS, a standard PLS algorithm was also applied on the same training and test sets. Our results show that the K-PLS produced reasonable results that outperformed the PLS model on the datasets. The obtained K-PLS model will be helpful for the design of novel nicotine-like selective CYP2A6 inhibitors.
Belekar, Vilas; Lingineni, Karthik; Garg, Prabha
2015-01-01
The breast cancer resistant protein (BCRP) is an important transporter and its inhibitors play an important role in cancer treatment by improving the oral bioavailability as well as blood brain barrier (BBB) permeability of anticancer drugs. In this work, a computational model was developed to predict the compounds as BCRP inhibitors or non-inhibitors. Various machine learning approaches like, support vector machine (SVM), k-nearest neighbor (k-NN) and artificial neural network (ANN) were used to develop the models. The Matthews correlation coefficients (MCC) of developed models using ANN, k-NN and SVM are 0.67, 0.71 and 0.77, and prediction accuracies are 85.2%, 88.3% and 90.8% respectively. The developed models were tested with a test set of 99 compounds and further validated with external set of 98 compounds. Distribution plot analysis and various machine learning models were also developed based on druglikeness descriptors. Applicability domain is used to check the prediction reliability of the new molecules.
Sanchez, Ana M; Denny, Thomas N; O'Gorman, Maurice
2014-07-01
This Special Issue of the Journal of Immunological Methods includes 16 manuscripts describing quality assurance activities related to virologic and immunologic monitoring of six global laboratory resource programs that support international HIV/AIDS clinical trial studies: Collaboration for AIDS Vaccine Discovery (CAVD); Center for HIV/AIDS Vaccine Immunology (CHAVI); External Quality Assurance Program Oversight Laboratory (EQAPOL); HIV Vaccine Trial Network (HVTN); International AIDS Vaccine Initiative (IAVI); and Immunology Quality Assessment (IQA). The reports from these programs address the many components required to develop comprehensive quality control activities and subsequent quality assurance programs for immune monitoring in global clinical trials including: all aspects of processing, storing, and quality assessment of PBMC preparations used ubiquitously in HIV clinical trials, the development and optimization of assays for CD8 HIV responses and HIV neutralization, a comprehensive global HIV virus repository, and reports on the development and execution of novel external proficiency testing programs for immunophenotyping, intracellular cytokine staining, ELISPOT and luminex based cytokine measurements. In addition, there are articles describing the implementation of Good Clinical Laboratory Practices (GCLP) in a large quality assurance laboratory, the development of statistical methods specific for external proficiency testing assessment, a discussion on the ability to set objective thresholds for measuring rare events by flow cytometry, and finally, a manuscript which addresses a framework for the structured reporting of T cell immune function based assays. It is anticipated that this series of manuscripts covering a wide range of quality assurance activities associated with the conduct of global clinical trials will provide a resource for individuals and programs involved in improving the harmonization, standardization, accuracy, and sensitivity of virologic and immunologic testing. Copyright © 2014 Elsevier B.V. All rights reserved.
Tsanaclis, Lolita; Nutt, James; Bagley, Kim; Bevan, Sian; Wicks, John
2014-06-01
It is possible for hair to be externally contaminated by drugs like cannabis or cocaine, which are smoked or snorted. Three steps are commonly employed to minimize the chance of external contamination causing misinterpretation of the results of a hair test. The first consists of decontamination of hair samples by washing the hair before analysis, the second is the use of cut-off levels, and the third is the detection of both the parent drugs and appropriate levels of their metabolite(s) in the hair sample. We propose an additional step for the assessment of drug use using hair samples combined with decontamination data. Hair samples from 186 drug users were analyzed along with their wash residues by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The results of the hair analysis of the 140 samples for cocaine showed that 85.5% (N=89) of the samples passed 'cocaine use' criteria for metabolites ratios and 12.5% (N=13) for wash residue criteria (<10% of cocaine in the wash residue) leading to conclusive interpretation. Only two cases (1.9%) had an uncertain conclusion of drug consumption because cocaine levels in the wash residue were >10% of the levels in the hair. The results of the cannabis set of samples (N=46) were not as clear-cut, as a comparatively large number of samples (15.2%) had relatively high levels of THC in the wash residues. To use this approach, it is important that laboratories testing drugs in hair samples can demonstrate that the method utilized does not generate significant levels of the cocaine metabolites. Copyright © 2014 John Wiley & Sons, Ltd.
Integrated decision strategies for skin sensitization hazard.
Strickland, Judy; Zang, Qingda; Kleinstreuer, Nicole; Paris, Michael; Lehmann, David M; Choksi, Neepa; Matheson, Joanna; Jacobs, Abigail; Lowit, Anna; Allen, David; Casey, Warren
2016-09-01
One of the top priorities of the Interagency Coordinating Committee for the Validation of Alternative Methods (ICCVAM) is the identification and evaluation of non-animal alternatives for skin sensitization testing. Although skin sensitization is a complex process, the key biological events of the process have been well characterized in an adverse outcome pathway (AOP) proposed by the Organisation for Economic Co-operation and Development (OECD). Accordingly, ICCVAM is working to develop integrated decision strategies based on the AOP using in vitro, in chemico and in silico information. Data were compiled for 120 substances tested in the murine local lymph node assay (LLNA), direct peptide reactivity assay (DPRA), human cell line activation test (h-CLAT) and KeratinoSens assay. Data for six physicochemical properties, which may affect skin penetration, were also collected, and skin sensitization read-across predictions were performed using OECD QSAR Toolbox. All data were combined into a variety of potential integrated decision strategies to predict LLNA outcomes using a training set of 94 substances and an external test set of 26 substances. Fifty-four models were built using multiple combinations of machine learning approaches and predictor variables. The seven models with the highest accuracy (89-96% for the test set and 96-99% for the training set) for predicting LLNA outcomes used a support vector machine (SVM) approach with different combinations of predictor variables. The performance statistics of the SVM models were higher than any of the non-animal tests alone and higher than simple test battery approaches using these methods. These data suggest that computational approaches are promising tools to effectively integrate data sources to identify potential skin sensitizers without animal testing. Published 2016. This article has been contributed to by US Government employees and their work is in the public domain in the USA. Published 2016. This article has been contributed to by US Government employees and their work is in the public domain in the USA.
Predicting Mouse Liver Microsomal Stability with “Pruned” Machine Learning Models and Public Data
Perryman, Alexander L.; Stratton, Thomas P.; Ekins, Sean; Freundlich, Joel S.
2015-01-01
Purpose Mouse efficacy studies are a critical hurdle to advance translational research of potential therapeutic compounds for many diseases. Although mouse liver microsomal (MLM) stability studies are not a perfect surrogate for in vivo studies of metabolic clearance, they are the initial model system used to assess metabolic stability. Consequently, we explored the development of machine learning models that can enhance the probability of identifying compounds possessing MLM stability. Methods Published assays on MLM half-life values were identified in PubChem, reformatted, and curated to create a training set with 894 unique small molecules. These data were used to construct machine learning models assessed with internal cross-validation, external tests with a published set of antitubercular compounds, and independent validation with an additional diverse set of 571 compounds (PubChem data on percent metabolism). Results “Pruning” out the moderately unstable/moderately stable compounds from the training set produced models with superior predictive power. Bayesian models displayed the best predictive power for identifying compounds with a half-life ≥1 hour. Conclusions Our results suggest the pruning strategy may be of general benefit to improve test set enrichment and provide machine learning models with enhanced predictive value for the MLM stability of small organic molecules. This study represents the most exhaustive study to date of using machine learning approaches with MLM data from public sources. PMID:26415647
Predicting Mouse Liver Microsomal Stability with "Pruned" Machine Learning Models and Public Data.
Perryman, Alexander L; Stratton, Thomas P; Ekins, Sean; Freundlich, Joel S
2016-02-01
Mouse efficacy studies are a critical hurdle to advance translational research of potential therapeutic compounds for many diseases. Although mouse liver microsomal (MLM) stability studies are not a perfect surrogate for in vivo studies of metabolic clearance, they are the initial model system used to assess metabolic stability. Consequently, we explored the development of machine learning models that can enhance the probability of identifying compounds possessing MLM stability. Published assays on MLM half-life values were identified in PubChem, reformatted, and curated to create a training set with 894 unique small molecules. These data were used to construct machine learning models assessed with internal cross-validation, external tests with a published set of antitubercular compounds, and independent validation with an additional diverse set of 571 compounds (PubChem data on percent metabolism). "Pruning" out the moderately unstable / moderately stable compounds from the training set produced models with superior predictive power. Bayesian models displayed the best predictive power for identifying compounds with a half-life ≥1 h. Our results suggest the pruning strategy may be of general benefit to improve test set enrichment and provide machine learning models with enhanced predictive value for the MLM stability of small organic molecules. This study represents the most exhaustive study to date of using machine learning approaches with MLM data from public sources.
Correlation between external and internal respiratory motion: a validation study.
Ernst, Floris; Bruder, Ralf; Schlaefer, Alexander; Schweikard, Achim
2012-05-01
In motion-compensated image-guided radiotherapy, accurate tracking of the target region is required. This tracking process includes building a correlation model between external surrogate motion and the motion of the target region. A novel correlation method is presented and compared with the commonly used polynomial model. The CyberKnife system (Accuray, Inc., Sunnyvale/CA) uses a polynomial correlation model to relate externally measured surrogate data (optical fibres on the patient's chest emitting red light) to infrequently acquired internal measurements (X-ray data). A new correlation algorithm based on ɛ -Support Vector Regression (SVR) was developed. Validation and comparison testing were done with human volunteers using live 3D ultrasound and externally measured infrared light-emitting diodes (IR LEDs). Seven data sets (5:03-6:27 min long) were recorded from six volunteers. Polynomial correlation algorithms were compared to the SVR-based algorithm demonstrating an average increase in root mean square (RMS) accuracy of 21.3% (0.4 mm). For three signals, the increase was more than 29% and for one signal as much as 45.6% (corresponding to more than 1.5 mm RMS). Further analysis showed the improvement to be statistically significant. The new SVR-based correlation method outperforms traditional polynomial correlation methods for motion tracking. This method is suitable for clinical implementation and may improve the overall accuracy of targeted radiotherapy.
Stability of playfulness across environmental settings: a pilot study.
Rigby, Patricia; Gaik, Sandy
2007-01-01
The Test of Playfulness (ToP) was used in this pilot study to examine the stability of playfulness of 16 children with cerebral palsy (CP), aged 4-8 years, across three environmental settings: home, community, and school. Each videotaped play segment was scored using the ToP. The ANOVA statistic demonstrated a significant variance (p < 0.05) in the playfulness of the children across the 3 settings. The children were most playful at home and least playful at school (p < 0.05). The variability in playfulness across settings suggests that playful behaviors are influenced by factors external to the child. Eleven children were playful (achieving a positive ToP score) in at least one environment, which demonstrates that they had the capacity to be playful. Their play was supported in some settings and not in others. However, there was a lack of playfulness in 65% of the play segments suggesting that these children experience many barriers to their participation in play. Future research is needed to identify factors that help and hinder the playfulness of children with CP.
Strategic offloading of delayed intentions into the external environment.
Gilbert, Sam J
2015-01-01
In everyday life, we often use external artefacts such as diaries to help us remember intended behaviours. In addition, we commonly manipulate our environment, for example by placing reminders in noticeable places. Yet strategic offloading of intentions to the external environment is not typically permitted in laboratory tasks examining memory for delayed intentions. What factors influence our use of such strategies, and what behavioural consequences do they have? This article describes four online experiments (N = 1196) examining a novel web-based task in which participants hold intentions for brief periods, with the option to strategically externalize these intentions by creating a reminder. This task significantly predicted participants' fulfilment of a naturalistic intention embedded within their everyday activities up to one week later (with greater predictive ability than more traditional prospective memory tasks, albeit with weak effect size). Setting external reminders improved performance, and it was more prevalent in older adults. Furthermore, participants set reminders adaptively, based on (a) memory load, and (b) the likelihood of distraction. These results suggest the importance of metacognitive processes in triggering intention offloading, which can increase the probability that intentions are eventually fulfilled.
Prins, Noeline W.; Sanchez, Justin C.; Prasad, Abhishek
2014-01-01
Brain-Machine Interfaces (BMIs) can be used to restore function in people living with paralysis. Current BMIs require extensive calibration that increase the set-up times and external inputs for decoder training that may be difficult to produce in paralyzed individuals. Both these factors have presented challenges in transitioning the technology from research environments to activities of daily living (ADL). For BMIs to be seamlessly used in ADL, these issues should be handled with minimal external input thus reducing the need for a technician/caregiver to calibrate the system. Reinforcement Learning (RL) based BMIs are a good tool to be used when there is no external training signal and can provide an adaptive modality to train BMI decoders. However, RL based BMIs are sensitive to the feedback provided to adapt the BMI. In actor-critic BMIs, this feedback is provided by the critic and the overall system performance is limited by the critic accuracy. In this work, we developed an adaptive BMI that could handle inaccuracies in the critic feedback in an effort to produce more accurate RL based BMIs. We developed a confidence measure, which indicated how appropriate the feedback is for updating the decoding parameters of the actor. The results show that with the new update formulation, the critic accuracy is no longer a limiting factor for the overall performance. We tested and validated the system onthree different data sets: synthetic data generated by an Izhikevich neural spiking model, synthetic data with a Gaussian noise distribution, and data collected from a non-human primate engaged in a reaching task. All results indicated that the system with the critic confidence built in always outperformed the system without the critic confidence. Results of this study suggest the potential application of the technique in developing an autonomous BMI that does not need an external signal for training or extensive calibration. PMID:24904257
[Flexibility of cognitive activity depends on its context].
Kostandov, É A
2010-01-01
The main purpose of this survey is to explain the importance of set-shifting for a flexible cognitive activity. Working memory overload may result in set-shifting slowdown, i.e., in a more rigid set and in a less flexible cognitive activity. This effect displays itself in an increase of erroneous perceptions of external stimuli. Set rigidity level also depends on the cognitive activity context (i.e., on the type of external stimuli the person has to deal with). We analyzed EEG-coherence function and induced synchronization/desynchronization responses in theta (4-7 Hz) and low alpha (8-10 Hz) bands. Basing on these data, we discuss the role of tonic and phasic forms of cortico-hippocampal and fronto-thalamic systems' activation in cognitive activity flexibility.
AlzhCPI: A knowledge base for predicting chemical-protein interactions towards Alzheimer's disease.
Fang, Jiansong; Wang, Ling; Li, Yecheng; Lian, Wenwen; Pang, Xiaocong; Wang, Hong; Yuan, Dongsheng; Wang, Qi; Liu, Ai-Lin; Du, Guan-Hua
2017-01-01
Alzheimer's disease (AD) is a complicated progressive neurodegeneration disorder. To confront AD, scientists are searching for multi-target-directed ligands (MTDLs) to delay disease progression. The in silico prediction of chemical-protein interactions (CPI) can accelerate target identification and drug discovery. Previously, we developed 100 binary classifiers to predict the CPI for 25 key targets against AD using the multi-target quantitative structure-activity relationship (mt-QSAR) method. In this investigation, we aimed to apply the mt-QSAR method to enlarge the model library to predict CPI towards AD. Another 104 binary classifiers were further constructed to predict the CPI for 26 preclinical AD targets based on the naive Bayesian (NB) and recursive partitioning (RP) algorithms. The internal 5-fold cross-validation and external test set validation were applied to evaluate the performance of the training sets and test set, respectively. The area under the receiver operating characteristic curve (ROC) for the test sets ranged from 0.629 to 1.0, with an average of 0.903. In addition, we developed a web server named AlzhCPI to integrate the comprehensive information of approximately 204 binary classifiers, which has potential applications in network pharmacology and drug repositioning. AlzhCPI is available online at http://rcidm.org/AlzhCPI/index.html. To illustrate the applicability of AlzhCPI, the developed system was employed for the systems pharmacology-based investigation of shichangpu against AD to enhance the understanding of the mechanisms of action of shichangpu from a holistic perspective.
Magnetic Testing, and Modeling, Simulation and Analysis for Space Applications
NASA Technical Reports Server (NTRS)
Boghosian, Mary; Narvaez, Pablo; Herman, Ray
2012-01-01
The Aerospace Corporation (Aerospace) and Lockheed Martin Space Systems (LMSS) participated with Jet Propulsion Laboratory (JPL) in the implementation of a magnetic cleanliness program of the NASA/JPL JUNO mission. The magnetic cleanliness program was applied from early flight system development up through system level environmental testing. The JUNO magnetic cleanliness program required setting-up a specialized magnetic test facility at Lockheed Martin Space Systems for testing the flight system and a testing program with facility for testing system parts and subsystems at JPL. The magnetic modeling, simulation and analysis capability was set up and performed by Aerospace to provide qualitative and quantitative magnetic assessments of the magnetic parts, components, and subsystems prior to or in lieu of magnetic tests. Because of the sensitive nature of the fields and particles scientific measurements being conducted by the JUNO space mission to Jupiter, the imposition of stringent magnetic control specifications required a magnetic control program to ensure that the spacecraft's science magnetometers and plasma wave search coil were not magnetically contaminated by flight system magnetic interferences. With Aerospace's magnetic modeling, simulation and analysis and JPL's system modeling and testing approach, and LMSS's test support, the project achieved a cost effective approach to achieving a magnetically clean spacecraft. This paper presents lessons learned from the JUNO magnetic testing approach and Aerospace's modeling, simulation and analysis activities used to solve problems such as remnant magnetization, performance of hard and soft magnetic materials within the targeted space system in applied external magnetic fields.
Wang, Wenyi; Kim, Marlene T.; Sedykh, Alexander
2015-01-01
Purpose Experimental Blood–Brain Barrier (BBB) permeability models for drug molecules are expensive and time-consuming. As alternative methods, several traditional Quantitative Structure-Activity Relationship (QSAR) models have been developed previously. In this study, we aimed to improve the predictivity of traditional QSAR BBB permeability models by employing relevant public bio-assay data in the modeling process. Methods We compiled a BBB permeability database consisting of 439 unique compounds from various resources. The database was split into a modeling set of 341 compounds and a validation set of 98 compounds. Consensus QSAR modeling workflow was employed on the modeling set to develop various QSAR models. A five-fold cross-validation approach was used to validate the developed models, and the resulting models were used to predict the external validation set compounds. Furthermore, we used previously published membrane transporter models to generate relevant transporter profiles for target compounds. The transporter profiles were used as additional biological descriptors to develop hybrid QSAR BBB models. Results The consensus QSAR models have R2=0.638 for fivefold cross-validation and R2=0.504 for external validation. The consensus model developed by pooling chemical and transporter descriptors showed better predictivity (R2=0.646 for five-fold cross-validation and R2=0.526 for external validation). Moreover, several external bio-assays that correlate with BBB permeability were identified using our automatic profiling tool. Conclusions The BBB permeability models developed in this study can be useful for early evaluation of new compounds (e.g., new drug candidates). The combination of chemical and biological descriptors shows a promising direction to improve the current traditional QSAR models. PMID:25862462
ERIC Educational Resources Information Center
Redlich, Otto
1972-01-01
The foundation of science, and of thermodynamics in particular, can be developed cogently and without arbitrariness. The goal of science, description of nature, is externally given; it requires a set of basic concepts as indispensable tools. Mathematics has no similar externally given goal. (Author/TS)
Code of Federal Regulations, 2010 CFR
2010-01-01
... of External Power Supplies Z Appendix Z to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY ENERGY... Power Supplies 1. Scope: This appendix covers the test requirements used to measure energy consumption of external power supplies. 2. Definitions: The following definitions are for the purposes of...
Code of Federal Regulations, 2011 CFR
2011-01-01
... of External Power Supplies Z Appendix Z to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY ENERGY... Power Supplies 1. Scope: This appendix covers the test requirements used to measure energy consumption of external power supplies. 2. Definitions: The following definitions are for the purposes of...
Minimizing the Disruptive Effects of Prospective Memory in Simulated Air Traffic Control
Loft, Shayne; Smith, Rebekah E.; Remington, Roger
2015-01-01
Prospective memory refers to remembering to perform an intended action in the future. Failures of prospective memory can occur in air traffic control. In two experiments, we examined the utility of external aids for facilitating air traffic management in a simulated air traffic control task with prospective memory requirements. Participants accepted and handed-off aircraft and detected aircraft conflicts. The prospective memory task involved remembering to deviate from a routine operating procedure when accepting target aircraft. External aids that contained details of the prospective memory task appeared and flashed when target aircraft needed acceptance. In Experiment 1, external aids presented either adjacent or non-adjacent to each of the 20 target aircraft presented over the 40min test phase reduced prospective memory error by 11% compared to a condition without external aids. In Experiment 2, only a single target aircraft was presented a significant time (39min–42min) after presentation of the prospective memory instruction, and the external aids reduced prospective memory error by 34%. In both experiments, costs to the efficiency of non-prospective memory air traffic management (non-target aircraft acceptance response time, conflict detection response time) were reduced by non-adjacent aids compared to no aids or adjacent aids. In contrast, in both experiments, the efficiency of the prospective memory air traffic management (target aircraft acceptance response time) was facilitated by adjacent aids compared to non-adjacent aids. Together, these findings have potential implications for the design of automated alerting systems to maximize multi-task performance in work settings where operators monitor and control demanding perceptual displays. PMID:24059825
Drysdale, Cheri L.; Earl, Jennifer E.
2004-01-01
Objective: To investigate surface electromyographic (EMG) activity of the rectus abdominus and external oblique abdominus muscles during pelvic-tilt and abdominal-hollowing exercises performed in different positions. Design and Setting: 2 × 3 (exercise by position) within-subjects design with repeated measures on both factors. All testing was performed in a university laboratory. Subjects: Twenty-six healthy, active young adult females. Measurements: Surface EMG activity was recorded from the left and right rectus abdominus and external oblique muscles while the 2 exercises (pelvic tilt and abdominal hollowing) were performed in different positions (standard, legs supported, and legs unsupported). The standard position was supine in the crook-lying position, the supported position was with hips and knees flexed to 90° and legs supported on a platform, and the unsupported position was with hips and knees flexed to 90° without external support. Peak EMG activity was normalized to a maximum voluntary isometric contraction for each muscle. Results: For the rectus abdominus, there was an interaction between position and activity. Abdominal hollowing produced significantly less activity than the pelvic tilt in all positions. The difference between the 2 exercises with the legs unsupported was of a greater magnitude than the other 2 positions. For the external obliques, there was significantly lower activity during the abdominal hollowing compared with the pelvic tilting. The greatest muscle activity occurred with the legs-unsupported position during both exercises. Conclusions: Abdominal-hollowing exercises produced less rectus abdominus and external oblique activity than pelvic-tilting exercises. Abdominal hollowing may be performed with minimal activation of the large global abdominal muscles. PMID:15085209
Drysdale, Cheri L.; Earl, Jennifer E.; Hertel, Jay
2004-03-01
OBJECTIVE: To investigate surface electromyographic (EMG) activity of the rectus abdominus and external oblique abdominus muscles during pelvic-tilt and abdominal-hollowing exercises performed in different positions. DESIGN AND SETTING: 2 x 3 (exercise by position) within-subjects design with repeated measures on both factors. All testing was performed in a university laboratory. SUBJECTS: Twenty-six healthy, active young adult females. MEASUREMENTS: Surface EMG activity was recorded from the left and right rectus abdominus and external oblique muscles while the 2 exercises (pelvic tilt and abdominal hollowing) were performed in different positions (standard, legs supported, and legs unsupported). The standard position was supine in the crook-lying position, the supported position was with hips and knees flexed to 90 degrees and legs supported on a platform, and the unsupported position was with hips and knees flexed to 90 degrees without external support. Peak EMG activity was normalized to a maximum voluntary isometric contraction for each muscle. RESULTS: For the rectus abdominus, there was an interaction between position and activity. Abdominal hollowing produced significantly less activity than the pelvic tilt in all positions. The difference between the 2 exercises with the legs unsupported was of a greater magnitude than the other 2 positions. For the external obliques, there was significantly lower activity during the abdominal hollowing compared with the pelvic tilting. The greatest muscle activity occurred with the legs-unsupported position during both exercises. CONCLUSIONS: Abdominal-hollowing exercises produced less rectus abdominus and external oblique activity than pelvic-tilting exercises. Abdominal hollowing may be performed with minimal activation of the large global abdominal muscles.
Motor set in Parkinson's disease.
Robertson, C; Flowers, K A
1990-01-01
Three experiments employing a five-choice button-pressing task tested the ability of Parkinsonian patients to learn and generate sequences of movement, and to switch between alternative sequences at will. It was found that patients could learn and generate individual patterns of movement normally, even complex ones involving an incompatible stimulus-response relationship. They had difficulty, however, in maintaining a sequence if two different ones had been learnt and subjects were required to switch spontaneously from one to the other within a trial. Providing external cues at the start of each sequence to guide the ordering of movements improved the stability of patients' performance. Most errors in sequencing consisted of reverting to the alternative pattern of movement. Parkinsonian subjects thus show an impairment in motor set similar to that found previously in cognitive activity. Images PMID:2391523
Albores-Gallo, Lilia; Hernández-Guzmán, Laura; Hasfura-Buenaga, Cecilia; Navarro-Luna, Enrique
To investigate the validity and internal consistency of the Mexican version of the CBCL/1.5 -5 that assesses the most common psychopathology in pre-school children in clinical and epidemiological settings. A total of 438 parents from two groups, clinical-psychiatric (N= 62) and community (N= 376) completed the CBCL/1.5-5/Mexican version. The internal consistency was high for total problems α=0.95, and internalized α=0.89 and externalized α=0.91 subscales. The test re-test (one week) using the intraclass correlation coefficient (ICC) was ≥ 0.95 for the internalized, externalized, and total problems subscales. The ROC curve for the criterion status of clinically-referred vs. non-referred using the total problems scale ≥ 24 resulted in an AUC (area under curve) of 0.77, a specificity 0.73, and a sensitivity of 0.70. The CBCL/1.5 -5/Mexican version is a reliable and valid tool. Copyright © 2016 Sociedad Chilena de Pediatría. Publicado por Elsevier España, S.L.U. All rights reserved.
Use of the Monte Carlo Method for OECD Principles-Guided QSAR Modeling of SIRT1 Inhibitors.
Kumar, Ashwani; Chauhan, Shilpi
2017-01-01
SIRT1 inhibitors offer therapeutic potential for the treatment of a number of diseases including cancer and human immunodeficiency virus infection. A diverse series of 45 compounds with reported SIRT1 inhibitory activity has been employed for the development of quantitative structure-activity relationship (QSAR) models using the Monte Carlo optimization method. This method makes use of simplified molecular input line entry system notation of the molecular structure. The QSAR models were built up according to OECD principles. Three subsets of three splits were examined and validated by respective external sets. All the three described models have good statistical quality. The best model has the following statistical characteristics: R 2 = 0.8350, Q 2 test = 0.7491 for the test set and R 2 = 0.9655, Q 2 ext = 0.9261 for the validation set. In the mechanistic interpretation, structural attributes responsible for the endpoint increase and decrease are defined. Further, the design of some prospective SIRT1 inhibitors is also presented on the basis of these structural attributes. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
2014-01-01
Background Risk adjustment is crucial for comparison of outcome in medical care. Knowledge of the external factors that impact measured outcome but that cannot be influenced by the physician is a prerequisite for this adjustment. To date, a universal and reproducible method for identification of the relevant external factors has not been published. The selection of external factors in current quality assurance programmes is mainly based on expert opinion. We propose and demonstrate a methodology for identification of external factors requiring risk adjustment of outcome indicators and we apply it to a cataract surgery register. Methods Defined test criteria to determine the relevance for risk adjustment are “clinical relevance” and “statistical significance”. Clinical relevance of the association is presumed when observed success rates of the indicator in the presence and absence of the external factor exceed a pre-specified range of 10%. Statistical significance of the association between the external factor and outcome indicators is assessed by univariate stratification and multivariate logistic regression adjustment. The cataract surgery register was set up as part of a German multi-centre register trial for out-patient cataract surgery in three high-volume surgical sites. A total of 14,924 patient follow-ups have been documented since 2005. Eight external factors potentially relevant for risk adjustment were related to the outcome indicators “refractive accuracy” and “visual rehabilitation” 2–5 weeks after surgery. Results The clinical relevance criterion confirmed 2 (“refractive accuracy”) and 5 (“visual rehabilitation”) external factors. The significance criterion was verified in two ways. Univariate and multivariate analyses revealed almost identical external factors: 4 were related to “refractive accuracy” and 7 (6) to “visual rehabilitation”. Two (“refractive accuracy”) and 5 (“visual rehabilitation”) factors conformed to both criteria and were therefore relevant for risk adjustment. Conclusion In a practical application, the proposed method to identify relevant external factors for risk adjustment for comparison of outcome in healthcare proved to be feasible and comprehensive. The method can also be adapted to other quality assurance programmes. However, the cut-off score for clinical relevance needs to be individually assessed when applying the proposed method to other indications or indicators. PMID:24965949
Insightful practice: a reliable measure for medical revalidation
Guthrie, Bruce; Sullivan, Frank M; Mercer, Stewart W; Russell, Andrew; Bruce, David A
2012-01-01
Background Medical revalidation decisions need to be reliable if they are to reassure on the quality and safety of professional practice. This study tested an innovative method in which general practitioners (GPs) were assessed on their reflection and response to a set of externally specified feedback. Setting and participants 60 GPs and 12 GP appraisers in the Tayside region of Scotland, UK. Methods A feedback dataset was specified as (1) GP-specific data collected by GPs themselves (patient and colleague opinion; open book self-evaluated knowledge test; complaints) and (2) Externally collected practice-level data provided to GPs (clinical quality and prescribing safety). GPs' perceptions of whether the feedback covered UK General Medical Council specified attributes of a ‘good doctor’ were examined using a mapping exercise. GPs' professionalism was examined in terms of appraiser assessment of GPs' level of insightful practice, defined as: engagement with, insight into and appropriate action on feedback data. The reliability of assessment of insightful practice and subsequent recommendations on GPs' revalidation by face-to-face and anonymous assessors were investigated using Generalisability G-theory. Main outcome measures Coverage of General Medical Council attributes by specified feedback and reliability of assessor recommendations on doctors' suitability for revalidation. Results Face-to-face assessment proved unreliable. Anonymous global assessment by three appraisers of insightful practice was highly reliable (G=0.85), as were revalidation decisions using four anonymous assessors (G=0.83). Conclusions Unlike face-to-face appraisal, anonymous assessment of insightful practice offers a valid and reliable method to decide GP revalidation. Further validity studies are needed. PMID:22653078
Beutel, Manfred E; Brähler, Elmar; Wiltink, Jörg; Michal, Matthias; Klein, Eva M; Jünger, Claus; Wild, Philipp S; Münzel, Thomas; Blettner, Maria; Lackner, Karl; Nickels, Stefan; Tibubos, Ana N
2017-01-01
Aim of the study was the development and validation of the psychometric properties of a six-item bi-factorial instrument for the assessment of social support (emotional and tangible support) with a population-based sample. A cross-sectional data set of N = 15,010 participants enrolled in the Gutenberg Health Study (GHS) in 2007-2012 was divided in two sub-samples. The GHS is a population-based, prospective, observational single-center cohort study in the Rhein-Main-Region in western Mid-Germany. The first sub-sample was used for scale development by performing an exploratory factor analysis. In order to test construct validity, confirmatory factor analyses were run to compare the extracted bi-factorial model with the one-factor solution. Reliability of the scales was indicated by calculating internal consistency. External validity was tested by investigating demographic characteristics health behavior, and distress using analysis of variance, Spearman and Pearson correlation analysis, and logistic regression analysis. Based on an exploratory factor analysis, a set of six items was extracted representing two independent factors. The two-factor structure of the Brief Social Support Scale (BS6) was confirmed by the results of the confirmatory factor analyses. Fit indices of the bi-factorial model were good and better compared to the one-factor solution. External validity was demonstrated for the BS6. The BS6 is a reliable and valid short scale that can be applied in social surveys due to its brevity to assess emotional and practical dimensions of social support.
A New Facility for Testing Superconducting Solenoid Magnets with Large Fringe Fields at Fermilab
DOE Office of Scientific and Technical Information (OSTI.GOV)
Orris, D.; Carcagno, R.; Nogiec, J.
2013-09-01
Testing superconducting solenoid with no iron flux return can be problematic for a magnet test facility due to the large magnetic fringe fields generated. These large external fields can interfere with the operation of equipment while precautions must be taken for personnel supporting the test. The magnetic forces between the solenoid under test and the external infrastructure must also be taken under consideration. A new test facility has been designed and built at Fermilab specifically for testing superconducting magnets with large external fringe fields. This paper discusses the test stand design, capabilities, and details of the instrumentation and controls withmore » data from the first solenoid tested in this facility: the Muon Ionization Cooling Experiment (MICE) coupling coil.« less
Nakagami, Katsuyuki; Yamauchi, Toyoaki; Noguchi, Hiroyuki; Maeda, Tohru; Nakagami, Tomoko
2014-06-01
This study aimed to develop a reliable and valid measure of functional health literacy in a Japanese clinical setting. Test development consisted of three phases: generation of an item pool, consultation with experts to assess content validity, and comparison with external criteria (the Japanese Health Knowledge Test) to assess criterion validity. A trial version of the test was administered to 535 Japanese outpatients. Internal consistency reliability, calculated by Cronbach's alpha, was 0.81, and concurrent validity was moderate. Receiver Operating Characteristics and Item Response Theory were used to classify patients as having adequate, marginal, or inadequate functional health literacy. Both inadequate and marginal functional health literacy were associated with older age, lower income, lower educational attainment, and poor health knowledge. The time required to complete the test was 10-15 min. This test should enable health workers to better identify patients with inadequate health literacy. © 2013 Wiley Publishing Asia Pty Ltd.
Huang, Tao; Li, Xiao-yu; Jin, Rui; Ku, Jing; Xu, Sen-miao; Xu, Meng-ling; Wu, Zhen-zhong; Kong, De-guo
2015-04-01
The present paper put forward a non-destructive detection method which combines semi-transmission hyperspectral imaging technology with manifold learning dimension reduction algorithm and least squares support vector machine (LSSVM) to recognize internal and external defects in potatoes simultaneously. Three hundred fifteen potatoes were bought in farmers market as research object, and semi-transmission hyperspectral image acquisition system was constructed to acquire the hyperspectral images of normal external defects (bud and green rind) and internal defect (hollow heart) potatoes. In order to conform to the actual production, defect part is randomly put right, side and back to the acquisition probe when the hyperspectral images of external defects potatoes are acquired. The average spectrums (390-1,040 nm) were extracted from the region of interests for spectral preprocessing. Then three kinds of manifold learning algorithm were respectively utilized to reduce the dimension of spectrum data, including supervised locally linear embedding (SLLE), locally linear embedding (LLE) and isometric mapping (ISOMAP), the low-dimensional data gotten by manifold learning algorithms is used as model input, Error Correcting Output Code (ECOC) and LSSVM were combined to develop the multi-target classification model. By comparing and analyzing results of the three models, we concluded that SLLE is the optimal manifold learning dimension reduction algorithm, and the SLLE-LSSVM model is determined to get the best recognition rate for recognizing internal and external defects potatoes. For test set data, the single recognition rate of normal, bud, green rind and hollow heart potato reached 96.83%, 86.96%, 86.96% and 95% respectively, and he hybrid recognition rate was 93.02%. The results indicate that combining the semi-transmission hyperspectral imaging technology with SLLE-LSSVM is a feasible qualitative analytical method which can simultaneously recognize the internal and external defects potatoes and also provide technical reference for rapid on-line non-destructive detecting of the internal and external defects potatoes.
Igual, Laura; Soliva, Joan Carles; Escalera, Sergio; Gimeno, Roger; Vilarroya, Oscar; Radeva, Petia
2012-12-01
We present a fully automatic diagnostic imaging test for Attention-Deficit/Hyperactivity Disorder diagnosis assistance based on previously found evidences of caudate nucleus volumetric abnormalities. The proposed method consists of different steps: a new automatic method for external and internal segmentation of caudate based on Machine Learning methodologies; the definition of a set of new volume relation features, 3D Dissociated Dipoles, used for caudate representation and classification. We separately validate the contributions using real data from a pediatric population and show precise internal caudate segmentation and discrimination power of the diagnostic test, showing significant performance improvements in comparison to other state-of-the-art methods. Copyright © 2012 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dasari, Paul K. R.; Shazeeb, Mohammed Salman; Könik, Arda
Purpose: Binning list-mode acquisitions as a function of a surrogate signal related to respiration has been employed to reduce the impact of respiratory motion on image quality in cardiac emission tomography (SPECT and PET). Inherent in amplitude binning is the assumption that there is a monotonic relationship between the amplitude of the surrogate signal and respiratory motion of the heart. This assumption is not valid in the presence of hysteresis when heart motion exhibits a different relationship with the surrogate during inspiration and expiration. The purpose of this study was to investigate the novel approach of using the Bouc–Wen (BW)more » model to provide a signal accounting for hysteresis when binning list-mode data with the goal of thereby improving motion correction. The study is based on the authors’ previous observations that hysteresis between chest and abdomen markers was indicative of hysteresis between abdomen markers and the internal motion of the heart. Methods: In 19 healthy volunteers, they determined the internal motion of the heart and diaphragm in the superior–inferior direction during free breathing using MRI navigators. A visual tracking system (VTS) synchronized with MRI acquisition tracked the anterior–posterior motions of external markers placed on the chest and abdomen. These data were employed to develop and test the Bouc–Wen model by inputting the VTS derived chest and abdomen motions into it and using the resulting output signals as surrogates for cardiac motion. The data of the volunteers were divided into training and testing sets. The training set was used to obtain initial values for the model parameters for all of the volunteers in the set, and for set members based on whether they were or were not classified as exhibiting hysteresis using a metric derived from the markers. These initial parameters were then employed with the testing set to estimate output signals. Pearson’s linear correlation coefficient between the abdomen, chest, average of chest and abdomen markers, and Bouc–Wen derived signals versus the true internal motion of the heart from MRI was used to judge the signals match to the heart motion. Results: The results show that the Bouc–Wen model generated signals demonstrated strong correlation with the heart motion. This correlation was slightly larger on average than that of the external surrogate signals derived from the abdomen marker, and average of the abdomen and chest markers, but was not statistically significantly different from them. Conclusions: The results suggest that the proposed model has the potential to be a unified framework for modeling hysteresis in respiratory motion in cardiac perfusion studies and beyond.« less
Efficacy test of a toothpaste in reducing extrinsic dental stain
NASA Astrophysics Data System (ADS)
Agustanti, A.; Ramadhani, S. A.; Adiatman, M.; Rahardjo, A.; Callea, M.; Yavuz, I.; Maharani, D. A.
2017-08-01
This clinical trial compared the external dental stain reduction achieved by tested toothpaste versus placebo in adult patients. In this double-blind, parallel, randomised clinical trial, 45 female volunteers with a mean age of 20 years old were included. All study subjects front teeth were topically applicated with Silver Diamine Fluoride (SDF) to create external dental stains. Subjects were randomized into test (n=22) and control (n=23) groups. Toothpastes were used for two days to analyse the effects of removing external stains on the labial surfaces of all anterior teeth. VITA Easyshade Advance 4.0 was used to measure dental extrinsic stains changes. The analysis showed statistically significant efficacy of the tested toothpaste in reducing external dental stain caused by SDF, comparing to the placebo toothpaste, after one and two days of usage. The tested toothpaste was effective in reducing dental stain.
Unal, Omer Kays; Poyanli, Oguz Sukru; Unal, Ulku Sur; Mutlu, Hasan Huseyin; Ozkut, Afsar Timucin; Esenkaya, Irfan
2018-05-16
We set out to reveal the effects of repeated sterilization, using different methods, on the carbon fiber rods of external fixator systems. We used a randomized set of forty-four unused, unsterilized, and identical carbon fiber rods (11 × 200 mm), randomly assigned to two groups: unsterilized (US) (4 rods) and sterilized (40 rods). The sterilized rods were divided into two groups, those sterilized in an autoclave (AC) and by hydrogen peroxide (HP). These were further divided into five subgroups based on the number of sterilization repetition to which the fibers were subjected (25-50-75-100-200). A bending test was conducted to measure the maximum bending force (MBF), maximum deflection (MD), flexural strength (FS), maximum bending moment (MBM) and bending rigidity (BR). We also measured the surface roughness of the rods. An increase in the number of sterilization repetition led to a decrease in MBF, MBM, FS, BR, but increased MD and surface roughness (p < 0.01). The effect of the number of sterilization repetition was more prominent in the HP group. This study revealed that the sterilization method and number of sterilization repetition influence the strength of the carbon fiber rods. Increasing the number of sterilization repetition degrades the strength and roughness of the rods.
Luo, Wen; Medrek, Sarah; Misra, Jatin; Nohynek, Gerhard J
2007-02-01
The objective of this study was to construct and validate a quantitative structure-activity relationship model for skin absorption. Such models are valuable tools for screening and prioritization in safety and efficacy evaluation, and risk assessment of drugs and chemicals. A database of 340 chemicals with percutaneous absorption was assembled. Two models were derived from the training set consisting 306 chemicals (90/10 random split). In addition to the experimental K(ow) values, over 300 2D and 3D atomic and molecular descriptors were analyzed using MDL's QsarIS computer program. Subsequently, the models were validated using both internal (leave-one-out) and external validation (test set) procedures. Using the stepwise regression analysis, three molecular descriptors were determined to have significant statistical correlation with K(p) (R2 = 0.8225): logK(ow), X0 (quantification of both molecular size and the degree of skeletal branching), and SsssCH (count of aromatic carbon groups). In conclusion, two models to estimate skin absorption were developed. When compared to other skin absorption QSAR models in the literature, our model incorporated more chemicals and explored a large number of descriptors. Additionally, our models are reasonably predictive and have met both internal and external statistical validations.
Baker, Kevin S; Cormican, Daniel; Seidman, Peggy A
2012-01-01
We describe the influence of a 6-week "Summer Anesthesiology Externship" featuring didactic, procedure, and simulation education on formation of medical students' specialty choice. Eighteen months after externship completion, externs were sent a questionnaire with Likert scale agreement ratings of subspecialties/simulations and yes/no questions about student career interests before/after the program, stipend importance, and procedural skill performance during/after the program. General anesthesiology had the highest subspecialty approval rating (9.0). Externs strongly agreed that simulations successfully progressed at first year student understanding levels (9.2 mean agreement rating), increased confidence in being part of a care team (9.4 mean agreement rating), and provided personal/interpersonal development. Externs unanimously agreed that the program introduced them to the breadth of anesthesiology, and that practicing clinical/procedural skills improved confidence when performing the procedures later in medical school. Four of 14 students applied for the externship with some focus on anesthesiology as a career choice. After the externship, a significantly higher number of students (12 of 14) were strongly considering applying to the field (p<0.0001). Eleven of 14 ultimately entered anesthesiology residencies, a significantly higher rate than our general medical student classes (p<0.0001). Both CA1 and CA3 resident post-test scores improved at the end of the ultrasound guided regional workshop. Our study showed a 68% improvement in test scores, which is larger than the 50% improvement previously reported. These results show that fast learning can occur in this type of setting. Furthermore, knowledge acquired during the workshop was retained when CA1 residents were re-tested one year after the workshop. The ultrasound-guided regional anesthesia workshop will become part of the didactic series for our CA1 residents and will be a required learning activity. Additional work still needs to be done to find out the best way to test knowledge and skill outcomes in residents learning new technology and techniques.
ERIC Educational Resources Information Center
Allen, George Cameron; Purves, Alan
External testing (public tests) is examined from a British point of view by George Cameron Allen and then responded to by an American. Allen discusses the history of external examinations in Britain, paying particular attention to the General Certificate of Education (GCE) examinations and the dichotomy that exists between language and literature…
NASA Astrophysics Data System (ADS)
Liu, Shuhuan; Du, Xuecheng; Du, Xiaozhi; Zhang, Yao; Mubashiru, Lawal Olarewaju; Luo, Dongyang; yuan, Yuan; Deng, Tianxiang; Li, Zhuoqi; Zang, Hang; Li, Yonghong; He, Chaohui; Ma, Yingqi; Shangguan, Shipeng
2017-09-01
The impacts of the external dynamic memory (DDR3) failures on the performance of 28 nm Xilinx Zynq-7010 SoC based system (MicroZed) were investigated with two sets of 1064 nm laser platforms. The failure sensitive area distributionsons on the back surface of the test DDR3 were primarily localized with a CW laser irradiation platform. During the CW laser scanning on the back surface of the DDR3 of the test board system, various failure modes except SEU and SEL (MBU, SEFI, data storage address error, rebooting, etc) were found in the testing embedded modules (ALU, PL, Register, Cache and DMA, etc) of SoC. Moreover, the experimental results demonstrated that there were 16 failure sensitive blocks symmetrically distributed on the back surface of the DDR3 with every sensitive block area measured was about 1 mm × 0.5 mm. The influence factors on the failure modes of the embedded modules were primarily analyzed and the SEE characteristics of DDR3 induced by the picoseconds pulsed laser were tested. The failure modes of DDR3 found were SEU, SEFI, SEL, test board rebooting by itself, unknown data, etc. Furthermore, the time interval distributions of failure occurrence in DDR3 changes with the pulsed laser irradiation energy and the CPU operating frequency were measured and compared. Meanwhile, the failure characteristics of DDR3 induced by pulsed laser irradiation were primarily explored. The measured results and the testing techniques designed in this paper provide some reference information for evaluating the reliability of the test system or other similar electronic system in harsh environment.
Robust scoring functions for protein-ligand interactions with quantum chemical charge models.
Wang, Jui-Chih; Lin, Jung-Hsin; Chen, Chung-Ming; Perryman, Alex L; Olson, Arthur J
2011-10-24
Ordinary least-squares (OLS) regression has been used widely for constructing the scoring functions for protein-ligand interactions. However, OLS is very sensitive to the existence of outliers, and models constructed using it are easily affected by the outliers or even the choice of the data set. On the other hand, determination of atomic charges is regarded as of central importance, because the electrostatic interaction is known to be a key contributing factor for biomolecular association. In the development of the AutoDock4 scoring function, only OLS was conducted, and the simple Gasteiger method was adopted. It is therefore of considerable interest to see whether more rigorous charge models could improve the statistical performance of the AutoDock4 scoring function. In this study, we have employed two well-established quantum chemical approaches, namely the restrained electrostatic potential (RESP) and the Austin-model 1-bond charge correction (AM1-BCC) methods, to obtain atomic partial charges, and we have compared how different charge models affect the performance of AutoDock4 scoring functions. In combination with robust regression analysis and outlier exclusion, our new protein-ligand free energy regression model with AM1-BCC charges for ligands and Amber99SB charges for proteins achieve lowest root-mean-squared error of 1.637 kcal/mol for the training set of 147 complexes and 2.176 kcal/mol for the external test set of 1427 complexes. The assessment for binding pose prediction with the 100 external decoy sets indicates very high success rate of 87% with the criteria of predicted root-mean-squared deviation of less than 2 Å. The success rates and statistical performance of our robust scoring functions are only weakly class-dependent (hydrophobic, hydrophilic, or mixed).
Construction bidding cost of KSC's space shuttle facilities
NASA Technical Reports Server (NTRS)
Brown, Joseph Andrew
1977-01-01
The bidding cost of the major Space Transportation System facilities constructed under the responsibility of the John F. Kennedy Space Center (KSC) is described and listed. These facilities and Ground Support Equipment (GSE) are necessary for the receiving, assembly, testing, and checkout of the Space Shuttle for launch and landing missions at KSC. The Shuttle launch configuration consists of the Orbiter, the External Tank, and the Solid Rocket Boosters (SRB). The reusable Orbiter and SRB's is the major factor in the program that will result in lowering space travel costs. The new facilities are the Landing Facility; Orbiter Processing Facility; Orbiter Approach and Landing Test Facility (Dryden Test Center, California); Orbiter Mating Devices; Sound Suppression Water System; and Emergency Power System for LC-39. Also, a major factor was to use as much Apollo facilities and hardware as possible to reduce the facilities cost. The alterations to existing Apollo facilities are the VAB modifications; Mobile Launcher Platforms; Launch Complex 39 Pads A and B (which includes a new concept - the Rotary Service Structure), which was featured in ENR, 3 Feb. 1977, 'Hinged Space Truss will Support Shuttle Cargo Room'; Launch Control Center mods; External Tank and SRB Processing and Storage; Fluid Test Complex mods; O&C Spacelab mods; Shuttle mods for Parachute Facility; SRB Recovery and Disassembly Facility at Hangar 'AF'; and an interesting GSE item - the SRB Dewatering Nozzle Plug Sets (Remote Controlled Submarine System) used to inspect and acquire for reuse of SRB's.
Altomare, Cristina; Guglielmann, Raffaella; Riboldi, Marco; Bellazzi, Riccardo; Baroni, Guido
2015-02-01
In high precision photon radiotherapy and in hadrontherapy, it is crucial to minimize the occurrence of geometrical deviations with respect to the treatment plan in each treatment session. To this end, point-based infrared (IR) optical tracking for patient set-up quality assessment is performed. Such tracking depends on external fiducial points placement. The main purpose of our work is to propose a new algorithm based on simulated annealing and augmented Lagrangian pattern search (SAPS), which is able to take into account prior knowledge, such as spatial constraints, during the optimization process. The SAPS algorithm was tested on data related to head and neck and pelvic cancer patients, and that were fitted with external surface markers for IR optical tracking applied for patient set-up preliminary correction. The integrated algorithm was tested considering optimality measures obtained with Computed Tomography (CT) images (i.e. the ratio between the so-called target registration error and fiducial registration error, TRE/FRE) and assessing the marker spatial distribution. Comparison has been performed with randomly selected marker configuration and with the GETS algorithm (Genetic Evolutionary Taboo Search), also taking into account the presence of organs at risk. The results obtained with SAPS highlight improvements with respect to the other approaches: (i) TRE/FRE ratio decreases; (ii) marker distribution satisfies both marker visibility and spatial constraints. We have also investigated how the TRE/FRE ratio is influenced by the number of markers, obtaining significant TRE/FRE reduction with respect to the random configurations, when a high number of markers is used. The SAPS algorithm is a valuable strategy for fiducial configuration optimization in IR optical tracking applied for patient set-up error detection and correction in radiation therapy, showing that taking into account prior knowledge is valuable in this optimization process. Further work will be focused on the computational optimization of the SAPS algorithm toward fast point-of-care applications. Copyright © 2014 Elsevier Inc. All rights reserved.
External doses of residents near Semipalatinsk nuclear test site.
Takada, J; Hoshi, M; Nagatomo, T; Yamamoto, M; Endo, S; Takatsuji, T; Yoshikawa, I; Gusev, B I; Sakerbaev, A K; Tchaijunusova, N J
1999-12-01
Accumulated external radiation doses of residents near the Semipalatinsk nuclear test site of the former USSR are presented as a results of study by the thermoluminescence technique for bricks sampled at several settlements in 1995 and 1996. The external doses that we evaluated from exposed bricks were up to about 100 cGy for resident. The external doses at several points in the center of Semipalatinsk City ranged from a background level to 60 cGy, which was remarkably high compared with the previously reported values based on military data.
Parenting and children's externalizing problems in substance-abusing families.
Stanger, Catherine; Dumenci, Levent; Kamon, Jody; Burstein, Marcy
2004-09-01
This study tested associations in path models among positive and negative parenting and children's rule-breaking behavior, aggressive and oppositional behavior, and attention problems for families with a drug-dependent parent. A structural model tested relations between parenting and children's externalizing problems for 251 families with 399 children between the ages of 6 and 18, controlling for nonindependence of ratings at the family level. The model also tested potential moderators, including child age, gender, and ethnicity (White vs. other), and caregiver gender (families with a female substance-abusing caregiver vs. families with a male substance-abusing caregiver). Results indicated that caregiver ratings of monitoring predicted rule-breaking behavior and use of inconsistent discipline predicted ratings of all 3 externalizing syndromes, after controlling parenting and externalizing problems for the effects of the moderators and after controlling significant relations among types of parenting and types of externalizing problems.
Quality assuring HIV point of care testing using whole blood samples.
Dare-Smith, Raellene; Badrick, Tony; Cunningham, Philip; Kesson, Alison; Badman, Susan
2016-08-01
The Royal College of Pathologists Australasia Quality Assurance Programs (RCPAQAP), have offered dedicated external quality assurance (EQA) for HIV point of care testing (PoCT) since 2011. Prior to this, EQA for these tests was available within the comprehensive human immunodeficiency virus (HIV) module. EQA testing for HIV has typically involved the supply of serum or plasma, while in the clinic or community based settings HIV PoCT is generally performed using whole blood obtained by capillary finger-stick collection. RCPAQAP has offered EQA for HIV PoCT using stabilised whole blood since 2014. A total of eight surveys have been undertaken over a period of 2 years from 2014 to 2015. Of the 962 responses received, the overall consensus rate was found to be 98% (941/962). A total of 21 errors were detected. The majority of errors were attributable to false reactive HIV p24 antigen results (9/21, 43%), followed by false reactive HIV antibody results (8/21, 38%). There were 4/21 (19%) false negative HIV antibody results and no false negative HIV p24 antigen results reported. Overall performance was observed to vary minimally between surveys, from a low of 94% up to 99% concordant. Encouraging levels of testing proficiency for HIV PoCT are indicated by these data, but they also confirm the need for HIV PoCT sites to participate in external quality assurance programs to ensure the ongoing provision of high quality patient care. Copyright © 2016 Royal College of Pathologists of Australasia. All rights reserved.
QSAR Modeling of Rat Acute Toxicity by Oral Exposure
Zhu, Hao; Martin, Todd M.; Ye, Lin; Sedykh, Alexander; Young, Douglas M.; Tropsha, Alexander
2009-01-01
Few Quantitative Structure-Activity Relationship (QSAR) studies have successfully modeled large, diverse rodent toxicity endpoints. In this study, a comprehensive dataset of 7,385 compounds with their most conservative lethal dose (LD50) values has been compiled. A combinatorial QSAR approach has been employed to develop robust and predictive models of acute toxicity in rats caused by oral exposure to chemicals. To enable fair comparison between the predictive power of models generated in this study versus a commercial toxicity predictor, TOPKAT (Toxicity Prediction by Komputer Assisted Technology), a modeling subset of the entire dataset was selected that included all 3,472 compounds used in the TOPKAT’s training set. The remaining 3,913 compounds, which were not present in the TOPKAT training set, were used as the external validation set. QSAR models of five different types were developed for the modeling set. The prediction accuracy for the external validation set was estimated by determination coefficient R2 of linear regression between actual and predicted LD50 values. The use of the applicability domain threshold implemented in most models generally improved the external prediction accuracy but expectedly led to the decrease in chemical space coverage; depending on the applicability domain threshold, R2 ranged from 0.24 to 0.70. Ultimately, several consensus models were developed by averaging the predicted LD50 for every compound using all 5 models. The consensus models afforded higher prediction accuracy for the external validation dataset with the higher coverage as compared to individual constituent models. The validated consensus LD50 models developed in this study can be used as reliable computational predictors of in vivo acute toxicity. PMID:19845371
ERIC Educational Resources Information Center
Prieß-Buchheit, Julia
2015-01-01
The Economic Actions in Education training module (EAE) teaches how to handle, use and judge external standardized tests in schools. The EAE programme was implemented in teacher training at the University of Kiel, because teachers are increasingly under external scrutiny and are being held accountable for student and school achievements. The EAE…
Da, Chenxiao; Mooberry, Susan L.; Gupton, John T.; Kellogg, Glen E.
2013-01-01
αβ-tubulin colchicine site inhibitors (CSIs) from four scaffolds that we previously tested for antiproliferative activity were modeled to better understand their effect on microtubules. Docking models, constructed by exploiting the SAR of a pyrrole subset and HINT scoring, guided ensemble docking of all 59 compounds. This conformation set and two variants having progressively less structure knowledge were subjected to CoMFA, CoMFA+HINT, and CoMSIA 3D-QSAR analyses. The CoMFA+HINT model (docked alignment) showed the best statistics: leave-one-out q2 of 0.616, r2 of 0.949 and r2pred (internal test set) of 0.755. An external (tested in other laboratories) collection of 24 CSIs from eight scaffolds were evaluated with the 3D-QSAR models, which correctly ranked their activity trends in 7/8 scaffolds for CoMFA+HINT (8/8 for CoMFA). The combination of SAR, ensemble docking, hydropathic analysis and 3D-QSAR provides an atomic-scale colchicine site model more consistent with a target structure resolution much higher than the ~3.6 Å available for αβ-tubulin. PMID:23961916
Naik, P K; Singh, T; Singh, H
2009-07-01
Quantitative structure-activity relationship (QSAR) analyses were performed independently on data sets belonging to two groups of insecticides, namely the organophosphates and carbamates. Several types of descriptors including topological, spatial, thermodynamic, information content, lead likeness and E-state indices were used to derive quantitative relationships between insecticide activities and structural properties of chemicals. A systematic search approach based on missing value, zero value, simple correlation and multi-collinearity tests as well as the use of a genetic algorithm allowed the optimal selection of the descriptors used to generate the models. The QSAR models developed for both organophosphate and carbamate groups revealed good predictability with r(2) values of 0.949 and 0.838 as well as [image omitted] values of 0.890 and 0.765, respectively. In addition, a linear correlation was observed between the predicted and experimental LD(50) values for the test set data with r(2) of 0.871 and 0.788 for both the organophosphate and carbamate groups, indicating that the prediction accuracy of the QSAR models was acceptable. The models were also tested successfully from external validation criteria. QSAR models developed in this study should help further design of novel potent insecticides.
Predicting Gene Structures from Multiple RT-PCR Tests
NASA Astrophysics Data System (ADS)
Kováč, Jakub; Vinař, Tomáš; Brejová, Broňa
It has been demonstrated that the use of additional information such as ESTs and protein homology can significantly improve accuracy of gene prediction. However, many sources of external information are still being omitted from consideration. Here, we investigate the use of product lengths from RT-PCR experiments in gene finding. We present hardness results and practical algorithms for several variants of the problem and apply our methods to a real RT-PCR data set in the Drosophila genome. We conclude that the use of RT-PCR data can improve the sensitivity of gene prediction and locate novel splicing variants.
Technicians complete foaming around Atlantis', OV-104, 17" ET feed line
1990-07-10
Technicians complete foaming around the area of Atlantis, Orbiter Vehicle (OV) 104, 17 inch diameter external tank (ET) feed line in preparation for the second liquid hydrogen tanking test at the Kennedy Space Center (KSC). An elaborate network of sensors, leak detectors, and baggies were set up on OV-104 by technicians. Engineers hope this extra instrumentation will help pinpoint the exact location of the leak. OV-104 is scheduled to be launched for the STS-38 mission, a classified Department of Defense (DOD) flight. View provided by KSC with alternate number KSC-90PC-988.
Technicians complete foaming around Atlantis', OV-104, 17' ET feed line
NASA Technical Reports Server (NTRS)
1990-01-01
Technicians complete foaming around the area of Atlantis, Orbiter Vehicle (OV) 104, 17 inch diameter external tank (ET) feed line in preparation for the second liquid hydrogen tanking test at the Kennedy Space Center (KSC). An elaborate network of sensors, leak detectors, and baggies were set up on OV-104 by technicians. Engineers hope this extra instrumentation will help pinpoint the exact location of the leak. OV-104 is scheduled to be launched for the STS-38 mission, a classified Department of Defense (DOD) flight. View provided by KSC with alternate number KSC-90PC-988.
Validation of the Economic and Health Outcomes Model of Type 2 Diabetes Mellitus (ECHO-T2DM).
Willis, Michael; Johansen, Pierre; Nilsson, Andreas; Asseburg, Christian
2017-03-01
The Economic and Health Outcomes Model of Type 2 Diabetes Mellitus (ECHO-T2DM) was developed to address study questions pertaining to the cost-effectiveness of treatment alternatives in the care of patients with type 2 diabetes mellitus (T2DM). Naturally, the usefulness of a model is determined by the accuracy of its predictions. A previous version of ECHO-T2DM was validated against actual trial outcomes and the model predictions were generally accurate. However, there have been recent upgrades to the model, which modify model predictions and necessitate an update of the validation exercises. The objectives of this study were to extend the methods available for evaluating model validity, to conduct a formal model validation of ECHO-T2DM (version 2.3.0) in accordance with the principles espoused by the International Society for Pharmacoeconomics and Outcomes Research (ISPOR) and the Society for Medical Decision Making (SMDM), and secondarily to evaluate the relative accuracy of four sets of macrovascular risk equations included in ECHO-T2DM. We followed the ISPOR/SMDM guidelines on model validation, evaluating face validity, verification, cross-validation, and external validation. Model verification involved 297 'stress tests', in which specific model inputs were modified systematically to ascertain correct model implementation. Cross-validation consisted of a comparison between ECHO-T2DM predictions and those of the seminal National Institutes of Health model. In external validation, study characteristics were entered into ECHO-T2DM to replicate the clinical results of 12 studies (including 17 patient populations), and model predictions were compared to observed values using established statistical techniques as well as measures of average prediction error, separately for the four sets of macrovascular risk equations supported in ECHO-T2DM. Sub-group analyses were conducted for dependent vs. independent outcomes and for microvascular vs. macrovascular vs. mortality endpoints. All stress tests were passed. ECHO-T2DM replicated the National Institutes of Health cost-effectiveness application with numerically similar results. In external validation of ECHO-T2DM, model predictions agreed well with observed clinical outcomes. For all sets of macrovascular risk equations, the results were close to the intercept and slope coefficients corresponding to a perfect match, resulting in high R 2 and failure to reject concordance using an F test. The results were similar for sub-groups of dependent and independent validation, with some degree of under-prediction of macrovascular events. ECHO-T2DM continues to match health outcomes in clinical trials in T2DM, with prediction accuracy similar to other leading models of T2DM.
A comparative study of internally and externally capped balloons using small scale test balloons
NASA Technical Reports Server (NTRS)
Bell, Douglas P.
1994-01-01
Caps have been used to structurally reinforce scientific research balloons since the late 1950's. The scientific research balloons used by the National Aeronautics and Space Administration (NASA) use internal caps. A NASA cap placement specification does not exist since no empirical information exisits concerning cap placement. To develop a cap placement specification, NASA has completed two in-hangar inflation tests comparing the structural contributions of internal caps and external caps. The tests used small scale test balloons designed to develop the highest possible stresses within the constraints of the hangar and balloon materials. An externally capped test balloon and an internally capped test balloon were designed, built, inflated and simulated to determine the structural contributions and benefits of each. The results of the tests and simulations are presented.
A Battery Certification Testbed for Small Satellite Missions
NASA Technical Reports Server (NTRS)
Cameron, Zachary; Kulkarni, Chetan S.; Luna, Ali Guarneros; Goebel, Kai; Poll, Scott
2015-01-01
A battery pack consisting of standard cylindrical 18650 lithium-ion cells has been chosen for small satellite missions based on previous flight heritage and compliance with NASA battery safety requirements. However, for batteries that transit through the International Space Station (ISS), additional certification tests are required for individual cells as well as the battery packs. In this manuscript, we discuss the development of generalized testbeds for testing and certifying different types of batteries critical to small satellite missions. Test procedures developed and executed for this certification effort include: a detailed physical inspection before and after experiments; electrical cycling characterization at the cell and pack levels; battery-pack overcharge, over-discharge, external short testing; battery-pack vacuum leak and vibration testing. The overall goals of these certification procedures are to conform to requirements set forth by the agency and identify unique safety hazards. The testbeds, procedures, and experimental results are discussed for batteries chosen for small satellite missions to be launched from the ISS.
Development of Subscale Fast Cookoff Test (PREPRINT)
2006-09-21
The hazards classification procedures have been harmonized with both the UN Test and Criteria Manual for UN Series 1...aimed at the development of a sub-scale alternate test protocol to the external fire test currently required for final hazards classification (HC...external fire test currently required for final hazards classification (HC) of an ordnance system. The specific goal of this part of the task was
van der Ploeg, Tjeerd; Nieboer, Daan; Steyerberg, Ewout W
2016-10-01
Prediction of medical outcomes may potentially benefit from using modern statistical modeling techniques. We aimed to externally validate modeling strategies for prediction of 6-month mortality of patients suffering from traumatic brain injury (TBI) with predictor sets of increasing complexity. We analyzed individual patient data from 15 different studies including 11,026 TBI patients. We consecutively considered a core set of predictors (age, motor score, and pupillary reactivity), an extended set with computed tomography scan characteristics, and a further extension with two laboratory measurements (glucose and hemoglobin). With each of these sets, we predicted 6-month mortality using default settings with five statistical modeling techniques: logistic regression (LR), classification and regression trees, random forests (RFs), support vector machines (SVM) and neural nets. For external validation, a model developed on one of the 15 data sets was applied to each of the 14 remaining sets. This process was repeated 15 times for a total of 630 validations. The area under the receiver operating characteristic curve (AUC) was used to assess the discriminative ability of the models. For the most complex predictor set, the LR models performed best (median validated AUC value, 0.757), followed by RF and support vector machine models (median validated AUC value, 0.735 and 0.732, respectively). With each predictor set, the classification and regression trees models showed poor performance (median validated AUC value, <0.7). The variability in performance across the studies was smallest for the RF- and LR-based models (inter quartile range for validated AUC values from 0.07 to 0.10). In the area of predicting mortality from TBI, nonlinear and nonadditive effects are not pronounced enough to make modern prediction methods beneficial. Copyright © 2016 Elsevier Inc. All rights reserved.
Development of The Science Processes Test.
ERIC Educational Resources Information Center
Ludeman, Robert R.
Presented is a description and copy of a test manual developed to include items in the test on the basis of children's performance; each item correlated highly with performance on an external criterion. The external criterion was the Individual Competency Measures of the elementary science program Science - A Process Approach (SAPA). The test…
Blum, David; Rosa, Daniel; deWolf-Linder, Susanne; Hayoz, Stefanie; Ribi, Karin; Koeberle, Dieter; Strasser, Florian
2014-12-01
Oncologists perform a range of pharmacological and nonpharmacological interventions to manage the symptoms of outpatients with advanced cancer. The aim of this study was to develop and test a symptom management performance checklist (SyMPeC) to review medical charts. First, the content of the checklist was determined by consensus of an interprofessional team. The SyMPeC was tested using the data set of the SAKK 96/06 E-MOSAIC (Electronical Monitoring of Symptoms and Syndromes Associated with Cancer) trial, which included six consecutive visits from 247 patients. In a test data set (half of the data) of medical charts, two people extracted and quantified the definitions of the parameters (content validity). To assess the inter-rater reliability, three independent researchers used the SyMPeC on a random sample (10% of the test data set), and Fleiss's kappa was calculated. To test external validity, the interventions retrieved by the SyMPeC chart review were compared with nurse-led assessment of patient-perceived oncologists' palliative interventions. Five categories of symptoms were included: pain, fatigue, anorexia/nausea, dyspnea, and depression/anxiety. Interventions were categorized as symptom specific or symptom unspecific. In the test data set of 123 patients, 402 unspecific and 299 symptom-specific pharmacological interventions were detected. Nonpharmacological interventions (n = 242) were mostly symptom unspecific. Fleiss's kappa for symptom and intervention detections was K = 0.7 and K = 0.86, respectively. In 1003 of 1167 visits (86%), there was a match between SyMPeC and nurse-led assessment. Seventy-nine percent (195 of 247) of patients had no or one mismatch. Chart review by SyMPeC seems reliable to detect symptom management interventions by oncologists in outpatient clinics. Nonpharmacological interventions were less symptom specific. A template for documentation is needed for standardization. Copyright © 2014 American Academy of Hospice and Palliative Medicine. Published by Elsevier Inc. All rights reserved.
Hills, Danny J
2017-07-01
Objectives The aim of the present study was to investigate differences in prevalence, as well as risk and protective factors, for exposure to workplace aggression between male and female clinicians in Australian medical practice settings. Methods In a cross-sectional, self-report study in the third wave of the Medicine in Australia: Balancing Employment and Life survey (2010-11), 16327 medical practitioners were sampled, with 9449 (57.9%) respondents working in clinical practice. Using backward stepwise elimination, parsimonious logistic regression models were developed for exposure to aggression from external (patients, patients' relatives or carers and others) and internal (co-workers) sources in the previous 12 months. Results Overall, greater proportions of female than male clinicians experienced aggression from external (P<0.001) and internal (P<0.01) sources in the previous 12 months. However, when stratified by doctor type, greater proportions of male than female general practitioners (GPs) and GP registrars experienced external aggression (P<0.05), whereas greater proportions of female than male specialists experienced external (P<0.01) and internal (P<0.01) aggression. In logistic regression models, differences were identified in relation to age for males and experience working in medicine for females with external and internal aggression; working in New South Wales (vs Victoria) and internal aggression for females; a poor medical support network and external aggression, and perceived unrealistic patient expectations with internal aggression for males; warning signs in reception and waiting areas with external aggression for males; and optimised patient waiting conditions with external and internal aggression for females. Conclusions Differences in risk and protective factors for exposure to workplace aggression between male and female clinicians, including in relation to state and rural location, need to be considered in the development and implementation of efforts to prevent and minimise workplace aggression in medical practice settings. What is known about the topic? Workplace aggression is prevalent in clinical medical settings, but there are conflicting reports about sex-based differences in the extent of exposure, and little evidence on differences in risk and protective factors for exposure to workplace aggression. What does this paper add? Differences in workplace aggression exposure rates between male and female clinicians are highlighted, including when stratified by doctor type. New evidence is reported on differences and similarities in key personal, professional and work-related factors associated with exposure to external and internal aggression. What are the implications for practitioners? In developing strategies for the prevention and minimisation of workplace aggression, consideration must be given to differences between male and female clinicians, including with regard to personality, age and professional experience, as well as work locations, conditions and settings, as risk or protective factors for exposure to aggression in medical work.
Core strength and lower extremity alignment during single leg squats.
Willson, John D; Ireland, Mary Lloyd; Davis, Irene
2006-05-01
Muscles of the trunk, hip, and knee influence the orientation of the lower extremity during weight bearing activities. The purpose of this study was threefold: first, to compare the orientation of the lower extremity during a single leg (SL) squat among male and female athletes; second, to compare the strength of muscle groups in the trunk, hips, and knees between these individuals; and third, to evaluate the association between trunk, hip, and knee strength and the orientation of the knee joint during this activity. Twenty-four male and 22 female athletes participated in this study. Peak isometric torque was determined for the following muscle actions: trunk flexion, extension, and lateral flexion, hip abduction and external rotation, and knee flexion and extension. The frontal plane projection angle (FPPA) of the knee during a 45 degrees SL squat was determined using photo editing software. Males and females moved in opposite directions during the SL squat test (F(1,42) = 5.05, P = 0.03). Females typically moved toward more extreme FPPA during SL squats (P = 0.056), while males tended to move toward more neutral alignment (P = 0.066). Females also generated less torque in all muscle groups, with the exception of trunk extension. The projection angle of the knee during the SL squat test was most closely associated with hip external rotation strength. Using instruments suitable for a clinical setting, females were found to have greater FPPA and generally decreased trunk, hip, and knee isometric torque. Hip external rotation strength was most closely associated with the frontal plane projection angle.
Zopf, David A.; Flanagan, Colleen L.; Wheeler, Matthew; Hollister, Scott J.; Green, Glenn E.
2015-01-01
Importance The study demonstrates an application for 3-dimensional (3D) printing that may serve as an effective intervention for severe tracheobronchomalacia. Objective A novel 3D printed, bioresorbable airway splint is tested for efficacy in extending survival in an animal model of severe, life-threatening tracheobronchomalacia. Participants Evaluation of an external airway splint for severe, life-threatening tracheobronchomalacia in a porcine animal model. Setting Multi-institutional and multidisciplinary collaboration between biomedical engineering laboratories and an academic animal surgery center. Interventions Experimental analysis of a 3D printed, bioresorbable airway splint is assessed in a porcine animal model of life-threatening tracheobronchomalacia. The open-cylindrical, bellow shaped porous polycaprolactone splint is placed externally and designed to suspend the underlying collapsed airway. Control animals (n=3) undergoing tracheal cartilage division and inner tracheal lumen dissociation and experimental animals (n=3) receiving the same model with overlying placement of the newly developed airway splint were evaluated. Main Outcomes and Measures An animal model for severe, life-threatening tracheobronchomalacia is proposed. Complete or near complete tracheal lumen collapse was observed in each animal with resolution of symptoms in all of the experimental animals after splint placement. Using our severe tracheobronchomalacia animal model, survival was significantly longer in duration in the experimental group receiving the airway splint after model creation when compared to model creation alone (p = 0.0495). Mortality in the experimental group was related to infection. Conclusions A multidisciplinary effort producing a CAD/CAM, bioresorbable tracheobronchial splint was tested in a porcine model of severe tracheomalacia and was found to extend survival. PMID:24232078
Korucu, M Kemal; Karademir, Aykan
2014-02-01
The procedure of a multi-criteria decision analysis supported by the geographic information systems was applied to the site selection process of a planning municipal solid waste management practice based on twelve different scenarios. The scenarios included two different decision tree modes and two different weighting models for three different area requirements. The suitability rankings of the suitable sites obtained from the application of the decision procedure for the scenarios were assessed by a factorial experimental design concerning the effect of some external criteria on the final decision of the site selection process. The external criteria used in the factorial experimental design were defined as "Risk perception and approval of stakeholders" and "Visibility". The effects of the presence of these criteria in the decision trees were evaluated in detail. For a quantitative expression of the differentiations observed in the suitability rankings, the ranking data were subjected to ANOVA test after a normalization process. Then the results of these tests were evaluated by Tukey test to measure the effects of external criteria on the final decision. The results of Tukey tests indicated that the involvement of the external criteria into the decision trees produced statistically meaningful differentiations in the suitability rankings. Since the external criteria could cause considerable external costs during the operation of the disposal facilities, the presence of these criteria in the decision tree in addition to the other criteria related to environmental and legislative requisites could prevent subsequent external costs in the first place.
2017-01-01
Purpose/Background Shoulder proprioception is essential in the activities of daily living as well as in sports. Acute muscle fatigue is believed to cause a deterioration of proprioception, increasing the risk of injury. The purpose of this study was to evaluate if fatigue of the shoulder external rotators during eccentric versus concentric activity affects shoulder joint proprioception as determined by active reproduction of position. Study design Quasi-experimental trial. Methods Twenty-two healthy subjects with no recent history of shoulder pathology were randomly allocated to either a concentric or an eccentric exercise group for fatiguing the shoulder external rotators. Proprioception was assessed before and after the fatiguing protocol using an isokinetic dynamometer, by measuring active reproduction of position at 30 ° of shoulder external rotation, reported as absolute angular error. The fatiguing protocol consisted of sets of fifteen consecutive external rotator muscle contractions in either the concentric or eccentric action. The subjects were exercised until there was a 30% decline from the peak torque of the subjects’ maximal voluntary contraction over three consecutive muscle contractions. Results A one-way analysis of variance test revealed no statistical difference in absolute angular error (p > 0.05) between concentric and eccentric groups. Moreover, no statistical difference (p > 0.05) was found in absolute angular error between pre- and post-fatigue in either group. Conclusions Eccentric exercise does not seem to acutely affect shoulder proprioception to a larger extent than concentric exercise. Level of evidence 2b PMID:28515976
Fleury, Sylvain; Jamet, Éric; Roussarie, Vincent; Bosc, Laure; Chamard, Jean-Christophe
2016-12-01
Virtually silent electric vehicles (EVs) may pose a risk for pedestrians. This paper describes two studies that were conducted to assess the influence of different types of external sounds on EV detectability. In the first study, blindfolded participants had to detect an approaching EV with either no warning sounds at all or one of three types of sound we tested. In the second study, designed to replicate the results of the first one in an ecological setting, the EV was driven along a road and the experimenters counted the number of people who turned their heads in its direction. Results of the first study showed that adding external sounds improve EV detection, and modulating the frequency and increasing the pitch of these sounds makes them more effective. This improvement was confirmed in the ecological context. Consequently, pitch variation and frequency modulation should both be taken into account in future AVAS design. Copyright © 2016 Elsevier Ltd. All rights reserved.
External quality assurance performance of clinical research laboratories in sub-saharan Africa.
Amukele, Timothy K; Michael, Kurt; Hanes, Mary; Miller, Robert E; Jackson, J Brooks
2012-11-01
Patient Safety Monitoring in International Laboratories (JHU-SMILE) is a resource at Johns Hopkins University that supports and monitors laboratories in National Institutes of Health-funded international clinical trials. To determine the impact of the JHU-SMILE quality assurance scheme in sub-Saharan African laboratories, we reviewed 40 to 60 months of external quality assurance (EQA) results of the College of American Pathologists (CAP) in these laboratories. We reviewed the performance of 8 analytes: albumin, alanine aminotransferase, creatinine, sodium, WBC, hemoglobin, hematocrit, and the human immunodeficiency virus antibody rapid test. Over the 40- to 60-month observation period, the sub-Saharan laboratories had a 1.63% failure rate, which was 40% lower than the 2011 CAP-wide rate of 2.8%. Seventy-six percent of the observed EQA failures occurred in 4 of the 21 laboratories. These results demonstrate that a system of remote monitoring, feedback, and audits can support quality in low-resource settings, even in places without strong regulatory support for laboratory quality.
NASA Astrophysics Data System (ADS)
Frassinetti, L.; Olofsson, K. E. J.; Fridström, R.; Setiadi, A. C.; Brunsell, P. R.; Volpe, F. A.; Drake, J.
2013-08-01
A new method for the estimate of the wall diffusion time of non-axisymmetric fields is developed. The method based on rotating external fields and on the measurement of the wall frequency response is developed and tested in EXTRAP T2R. The method allows the experimental estimate of the wall diffusion time for each Fourier harmonic and the estimate of the wall diffusion toroidal asymmetries. The method intrinsically considers the effects of three-dimensional structures and of the shell gaps. Far from the gaps, experimental results are in good agreement with the diffusion time estimated with a simple cylindrical model that assumes a homogeneous wall. The method is also applied with non-standard configurations of the coil array, in order to mimic tokamak-relevant settings with a partial wall coverage and active coils of large toroidal extent. The comparison with the full coverage results shows good agreement if the effects of the relevant sidebands are considered.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bhandare, N.
2014-06-01
Purpose: To estimate and compare the doses received by the obturator, external and internal iliac lymph nodes and point Methods: CT-MR fused image sets of 15 patients obtained for each of 5 fractions of HDR brachytherapy using tandem and ring applicator, were used to generate treatment plans optimized to deliver a prescription dose to HRCTV-D90 and to minimize the doses to organs at risk (OARs). For each set of image, target volume (GTV, HRCTV) OARs (Bladder, Rectum, Sigmoid), and both left and right pelvic lymph nodes (obturator, external and internal iliac lymph nodes) were delineated. Dose-volume histograms (DVH) were generatedmore » for pelvic nodal groups (left and right obturator group, internal and external iliac chains) Per fraction DVH parameters used for dose comparison included dose to 100% volume (D100), and dose received by 2cc (D2cc), 1cc (D1cc) and 0.1 cc (D0.1cc) of nodal volume. Dose to point B was compared with each DVH parameter using 2 sided t-test. Pearson correlation were determined to examine relationship of point B dose with nodal DVH parameters. Results: FIGO clinical stage varied from 1B1 to IIIB. The median pretreatment tumor diameter measured on MRI was 4.5 cm (2.7– 6.4cm).The median dose to bilateral point B was 1.20 Gy ± 0.12 or 20% of the prescription dose. The correlation coefficients were all <0.60 for all nodal DVH parameters indicating low degree of correlation. Only 2 cc of obturator nodes was not significantly different from point B dose on t-test. Conclusion: Dose to point B does not adequately represent the dose to any specific pelvic nodal group. When using image guided 3D dose-volume optimized treatment nodal groups should be individually identified and delineated to obtain the doses received by pelvic nodes.« less
Validation of a short-term memory test for the recognition of people and faces.
Leyk, D; Sievert, A; Heiss, A; Gorges, W; Ridder, D; Alexander, T; Wunderlich, M; Ruther, T
2008-08-01
Memorising and processing faces is a short-term memory dependent task of utmost importance in the security domain, in which constant and high performance is a must. Especially in access or passport control-related tasks, the timely identification of performance decrements is essential, margins of error are narrow and inadequate performance may have grave consequences. However, conventional short-term memory tests frequently use abstract settings with little relevance to working situations. They may thus be unable to capture task-specific decrements. The aim of the study was to devise and validate a new test, better reflecting job specifics and employing appropriate stimuli. After 1.5 s (short) or 4.5 s (long) presentation, a set of seven portraits of faces had to be memorised for comparison with two control stimuli. Stimulus appearance followed 2 s (first item) and 8 s (second item) after set presentation. Twenty eight subjects (12 male, 16 female) were tested at seven different times of day, 3 h apart. Recognition rates were above 60% even for the least favourable condition. Recognition was significantly better in the 'long' condition (+10%) and for the first item (+18%). Recognition time showed significant differences (10%) between items. Minor effects of learning were found for response latencies only. Based on occupationally relevant metrics, the test displayed internal and external validity, consistency and suitability for further use in test/retest scenarios. In public security, especially where access to restricted areas is monitored, margins of error are narrow and operator performance must remain high and level. Appropriate schedules for personnel, based on valid test results, are required. However, task-specific data and performance tests, permitting the description of task specific decrements, are not available. Commonly used tests may be unsuitable due to undue abstraction and insufficient reference to real-world conditions. Thus, tests are required that account for task-specific conditions and neurophysiological characteristics.
Method for Automatic Selection of Parameters in Normal Tissue Complication Probability Modeling.
Christophides, Damianos; Appelt, Ane L; Gusnanto, Arief; Lilley, John; Sebag-Montefiore, David
2018-07-01
To present a fully automatic method to generate multiparameter normal tissue complication probability (NTCP) models and compare its results with those of a published model, using the same patient cohort. Data were analyzed from 345 rectal cancer patients treated with external radiation therapy to predict the risk of patients developing grade 1 or ≥2 cystitis. In total, 23 clinical factors were included in the analysis as candidate predictors of cystitis. Principal component analysis was used to decompose the bladder dose-volume histogram into 8 principal components, explaining more than 95% of the variance. The data set of clinical factors and principal components was divided into training (70%) and test (30%) data sets, with the training data set used by the algorithm to compute an NTCP model. The first step of the algorithm was to obtain a bootstrap sample, followed by multicollinearity reduction using the variance inflation factor and genetic algorithm optimization to determine an ordinal logistic regression model that minimizes the Bayesian information criterion. The process was repeated 100 times, and the model with the minimum Bayesian information criterion was recorded on each iteration. The most frequent model was selected as the final "automatically generated model" (AGM). The published model and AGM were fitted on the training data sets, and the risk of cystitis was calculated. The 2 models had no significant differences in predictive performance, both for the training and test data sets (P value > .05) and found similar clinical and dosimetric factors as predictors. Both models exhibited good explanatory performance on the training data set (P values > .44), which was reduced on the test data sets (P values < .05). The predictive value of the AGM is equivalent to that of the expert-derived published model. It demonstrates potential in saving time, tackling problems with a large number of parameters, and standardizing variable selection in NTCP modeling. Crown Copyright © 2018. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Zaborowicz, M.; Przybył, J.; Koszela, K.; Boniecki, P.; Mueller, W.; Raba, B.; Lewicki, A.; Przybył, K.
2014-04-01
The aim of the project was to make the software which on the basis on image of greenhouse tomato allows for the extraction of its characteristics. Data gathered during the image analysis and processing were used to build learning sets of artificial neural networks. Program enables to process pictures in jpeg format, acquisition of statistical information of the picture and export them to an external file. Produced software is intended to batch analyze collected research material and obtained information saved as a csv file. Program allows for analysis of 33 independent parameters implicitly to describe tested image. The application is dedicated to processing and image analysis of greenhouse tomatoes. The program can be used for analysis of other fruits and vegetables of a spherical shape.
NASA Technical Reports Server (NTRS)
Cummings, J. W.; Foster, T. F.; Lockman, W. K.
1976-01-01
Data obtained from a heat transfer test conducted on an 0.006-scale space shuttle orbiter and external tank in the NASA-Ames Research Center 3.5-foot Hypersonic Wind Tunnel are presented. The purpose of this test was to obtain data under simulated return-to-launch-site abort conditions. Configurations tested were integrated orbiter and external tank, orbiter alone, and external tank alone at angles of attack of 0, + or - 30, + or - 60, + or - 90, and + or - 120 degrees. Runs were conducted at Mach numbers of 5.2 and 5.3 for Reynolds numbers of 1.0 and 4.0 million per foot, respectively. Heat transfer data were obtained from 75 orbiter and 75 external tank iron-constantan thermocouples.
ERIC Educational Resources Information Center
Bertoni, Marco; Brunello, Giorgio; Rocco, Lorenzo
2013-01-01
We use a natural experiment to show that the presence of an external examiner has both a direct and an indirect negative effect on the performance of monitored classes in standardized educational tests. The direct effect is the difference in the test performance between classes of the same school with and without external examiners. The indirect…
High current lightning test of space shuttle external tank lightning protection system
NASA Technical Reports Server (NTRS)
Mumme, E.; Anderson, A.; Schulte, E. H.
1977-01-01
During lift-off, the shuttle launch vehicle (external tank, solid rocket booster and orbiter) may be subjected to a lightning strike. Tests of a proposed lightning protection method for the external tank and development materials which were subjected to simulated lightning strikes are described. Results show that certain of the high resistant paint strips performed remarkably well in diverting the 50 kA lightning strikes.
Players' perceptions of accountability factors in secondary school sports settings.
Hastie, P A
1993-06-01
The purpose of this study was to gauge the extent to which students believed that the accountability strategies employed by their coaches had significant effects on their involvement in sports training sessions. Questionnaire data from 235 secondary school athletes were analyzed using linear structural relations to test a model of accountability hypothesized as operating in these coaching settings. The accountability strategy of active instruction was found to be a variable that significantly affected the students' valuing of their coaches as well as their task involvement. However, the rewards/consequences variable was not found to be a predictor of valuing or task involvement, suggesting that these athletes seemed more task oriented than reliant on external sanctions. The results of this study can only be generalized to team sport settings. Detailed examination needs to be made of the processes through which accountability factors operate for other contexts, including individual sports and competitive levels. Further research could also be undertaken into gender differences, especially in relation to the gender of coaches.
Students' Construction of External Representations in Design-Based Learning Situations
ERIC Educational Resources Information Center
de Vries, Erica
2006-01-01
This article develops a theoretical framework for the study of students' construction of mixed multiple external representations in design-based learning situations involving an adaptation of professional tasks and tools to a classroom setting. The framework draws on research on professional design processes and on learning with multiple external…
Bianchi, Lorenzo; Schiavina, Riccardo; Borghesi, Marco; Bianchi, Federico Mineo; Briganti, Alberto; Carini, Marco; Terrone, Carlo; Mottrie, Alex; Gacci, Mauro; Gontero, Paolo; Imbimbo, Ciro; Marchioro, Giansilvio; Milanese, Giulio; Mirone, Vincenzo; Montorsi, Francesco; Morgia, Giuseppe; Novara, Giacomo; Porreca, Angelo; Volpe, Alessandro; Brunocilla, Eugenio
2018-04-06
To assess the predictive accuracy and the clinical value of a recent nomogram predicting cancer-specific mortality-free survival after surgery in pN1 prostate cancer patients through an external validation. We evaluated 518 prostate cancer patients treated with radical prostatectomy and pelvic lymph node dissection with evidence of nodal metastases at final pathology, at 10 tertiary centers. External validation was carried out using regression coefficients of the previously published nomogram. The performance characteristics of the model were assessed by quantifying predictive accuracy, according to the area under the curve in the receiver operating characteristic curve and model calibration. Furthermore, we systematically analyzed the specificity, sensitivity, positive predictive value and negative predictive value for each nomogram-derived probability cut-off. Finally, we implemented decision curve analysis, in order to quantify the nomogram's clinical value in routine practice. External validation showed inferior predictive accuracy as referred to in the internal validation (65.8% vs 83.3%, respectively). The discrimination (area under the curve) of the multivariable model was 66.7% (95% CI 60.1-73.0%) by testing with receiver operating characteristic curve analysis. The calibration plot showed an overestimation throughout the range of predicted cancer-specific mortality-free survival rates probabilities. However, in decision curve analysis, the nomogram's use showed a net benefit when compared with the scenarios of treating all patients or none. In an external setting, the nomogram showed inferior predictive accuracy and suboptimal calibration characteristics as compared to that reported in the original population. However, decision curve analysis showed a clinical net benefit, suggesting a clinical implication to correctly manage pN1 prostate cancer patients after surgery. © 2018 The Japanese Urological Association.
Jiao, Hongmei; Mei, Ling; Sharma, Tarun; Kern, Mark; Sanvanson, Patrick
2016-01-01
Oropharyngeal dysphagia due to upper esophageal sphincter (UES) dysfunction is commonly encountered in the clinical setting. Selective experimental perturbation of various components of the deglutitive apparatus can provide an opportunity to improve our understanding of the swallowing physiology and pathophysiology. The aim is to characterize the pharyngeal and UES deglutitive pressure phenomena in an experimentally induced restriction of UES opening in humans. We studied 14 volunteers without any dysphagic symptoms (7 men, 66 ± 11 yr) but with various supraesophageal reflux symptoms. To induce UES restriction, we used a handmade device that with adjustment could selectively apply 0, 20, 30, or 40 mmHg pressure perpendicularly to the cricoid cartilage. Deglutitive pharyngeal and UES pressure phenomena were determined during dry and 5- and 10-ml water swallows × 3 for each of the UES perturbations. External cricoid pressure against the UES resulted in a significant increase in hypopharyngeal intrabolus pressure and UES nadir deglutitive relaxation pressure for all tested swallowed volumes (P < 0.05). Application of external cricoid pressure increased the length of the UES high pressure zone from 2.5 ± 0.2 to 3.1 ± 0.2, 3.5 ± 0.1, and 3.7 ± 0.1 cm for 20, 30, and 40 mmHg cricoid pressure, respectively (P < 0.05). External cricoid pressure had no significant effect on pharyngeal peristalsis. On the other hand, irrespective of external cricoid pressure deglutitive velopharyngeal contractile integral progressively increased with increased swallowed volumes (P < 0.05). In conclusion, acute experimental restriction of UES opening by external cricoid pressure manifests the pressure characteristics of increased resistance to UES transsphincteric flow observed clinically without affecting the pharyngeal peristaltic contractile function. PMID:27198193
Schouteten, Joachim J; De Steur, Hans; Sas, Benedikt; De Bourdeaudhuij, Ilse; Gellynck, Xavier
2017-01-01
Although sensory and emotional evaluation of food products mostly occurs in a controlled laboratory environment, it is often criticized as it may not reflect a realistic situation for consumers. Moreover, products are mainly blind evaluated by participants, whereas external factors such as brand are often considered as key drivers of food choice. This study aims to examine the role of research setting (central location test versus home-use test) and brand information on the overall acceptance, and sensory and emotional profiling of 5 strawberry-flavored yogurts. Thereby, private label and premium brands are compared under 3 conditions: blind, expected, and informed (brand information). A total of 99 adult subjects participated in 3 sessions over 3 consecutive weeks. Results showed that overall liking for 2 yogurt samples was higher in the laboratory environment under the informed evaluation condition, whereas no effect of research setting was found under the blind and expected conditions. Although emotional profiles of the products differed depending on the research setting, this was less the case for the sensory profiles. Furthermore, brand information clearly affected the sensory perception of certain attributes but had less influence on overall liking and emotional profiling. These results indicate that both scientists and food companies should consider the effect of the chosen methodology on ecological validity when conducting sensory research with consumers because the laboratory context could lead to a more positive evaluation compared with a home-use test. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Mcdonald, E; Theologis, A A; Horst, P; Kandemir, U; Pekmezci, M
2015-12-01
This study aimed at evaluating the additional stability that is provided by anterior external and internal fixators in an unstable pelvic fracture model (OTA 61-C). An unstable pelvic fracture (OTA 61-C) was created in 27 synthetic pelves by making a 5-mm gap through the sacral foramina (posterior injury) and an ipsilateral pubic rami fracture (anterior injury). The posterior injury was fixed with either a single iliosacral (IS) screw, a single trans-iliac, trans-sacral (TS) screw, or two iliosacral screws (S1S2). Two anterior fixation techniques were utilized: external fixation (Ex-Fix) and supra-acetabular external fixation and internal fixation (In-Fix); supra-acetabular pedicle screws connected with a single subcutaneous spinal rod. The specimens were tested using a nondestructive single-leg stance model. Peak-to-peak (P2P) displacement and rotation and conditioning displacement (CD) were calculated. The Ex-Fix group failed in 83.3 % of specimens with concomitant single-level posterior fixation (Total: 15/18-7 of 9 IS fixation, 8 of 9 TS fixation), and 0 % (0/9) of specimens with concomitant two-level (S1S2) posterior fixation. All specimens with the In-Fix survived testing except for two specimens treated with In-Fix combined with IS fixation. Trans-sacral fixation had higher pubic rotation and greater sacral and pubic displacement than S1S2 (p < 0.05). Rotation of the pubis and sacrum was not different between In-Fix constructs combined with single-level IS and TS fixation. In this model of an unstable pelvic fracture (OTA 61-C), anterior fixation with an In-Fix was biomechanically superior to an anterior Ex-Fix in the setting of single-level posterior fixation. There was no biomechanical difference between the In-Fix and Ex-Fix when each was combined with two levels of posterior sacral fixation.
NASA Technical Reports Server (NTRS)
Walstad, D. G.
1975-01-01
Data are presented from heat transfer tests on an 0.0006-scale space shuttle vehicle in the Langley Research Center Nitrogen Tunnel. The purpose of this test was to obtain ascent heating data at a high hypersonic Mach number. Configurations tested were integrated orbiter and external tank, orbiter alone, and external tank alone. All configurations were tested with and without boundary layer transition. Testing was conducted at a Mach number of 19, a Reynolds number of 0.5 million per foot, and angles of attack of 0, + or - 5, and + or - 10 degrees. Heat transfer data was obtained from 77 orbiter and 90 external tank iron-constantan thermocouples.
Testing the External Effect of Household Behavior: The Case of the Demand for Children
ERIC Educational Resources Information Center
Li, Hongbin; Zhang, Junsen
2009-01-01
This paper tests the external effect of household childbearing behavior by drawing on microfertility data from China. The test is executed by regressing one woman's fertility on the average fertility of neighboring women. China's unique affirmative birth control policy provides us with quasi-experimental fertility variation that facilities…
1978-04-21
This is an interior ground level view of the Shuttle Orbiter Enterprise being lowered for mating to External Tank (ET) inside Marshall Space Flight Center's Dynamic Test Stand for Mated Vertical Ground Vibration tests (MVGVT). The tests marked the first time ever that the entire shuttle complement (including Orbiter, external tank, and solid rocket boosters) were mated vertically.
Kong, Ji-Sook; Lee, Yeon-Kyung; Kim, Mi Kyung; Choi, Mi-Kyeong; Heo, Young-Ran; Hyun, Taisun; Kim, Sun Mee; Lyu, Eun-Soon; Oh, Se-Young; Park, Hae-Ryun; Rhee, Moo-Yong; Ro, Hee-Kyong; Song, Mi Kyung
2018-01-01
This study was conducted to develop an equation for estimation of 24-h urinary-sodium excretion that can serve as an alternative to 24-h dietary recall and 24-h urine collection for normotensive Korean adults. In total, data on 640 healthy Korean adults aged 19 to 69 years from 4 regions of the country were collected as a training set. In order to externally validate the equation developed from that training set, 200 subjects were recruited independently as a validation set. Due to heterogeneity by gender, we constructed a gender-specific equation for estimation of 24-h urinary-sodium excretion by using a multivariable linear regression model and assessed the performance of the developed equation in validation set. The best model consisted of age, body weight, dietary behavior ('eating salty food', 'Kimchi consumption', 'Korean soup or stew consumption', 'soy sauce or red pepper paste consumption'), and smoking status in men, and age, body weight, dietary behavior ('salt preference', 'eating salty food', 'checking sodium content for processed foods', 'nut consumption'), and smoking status in women, respectively. When this model was tested in the external validation set, the mean bias between the measured and estimated 24-h urinary-sodium excretion from Bland-Altman plots was -1.92 (95% CI: -113, 110) mmol/d for men and -1.51 (95% CI: -90.6, 87.6) mmol/d for women. The cut-points of sodium intake calculated based on the equations were ≥4,000 mg/d for men and ≥3,500 mg/d for women, with 89.8 and 76.6% sensitivity and 29.3 and 64.2% specificity, respectively. In this study, a habitual 24-hour urinary-sodium-excretion-estimation model of normotensive Korean adults based on anthropometric and lifestyle factors was developed and showed feasibility for an asymptomatic population.
Choi, Mi-Kyeong; Heo, Young-Ran; Hyun, Taisun; Kim, Sun Mee; Lyu, Eun-Soon; Oh, Se-Young; Park, Hae-Ryun; Rhee, Moo-Yong; Ro, Hee-Kyong; Song, Mi Kyung
2018-01-01
This study was conducted to develop an equation for estimation of 24-h urinary-sodium excretion that can serve as an alternative to 24-h dietary recall and 24-h urine collection for normotensive Korean adults. In total, data on 640 healthy Korean adults aged 19 to 69 years from 4 regions of the country were collected as a training set. In order to externally validate the equation developed from that training set, 200 subjects were recruited independently as a validation set. Due to heterogeneity by gender, we constructed a gender-specific equation for estimation of 24-h urinary-sodium excretion by using a multivariable linear regression model and assessed the performance of the developed equation in validation set. The best model consisted of age, body weight, dietary behavior (‘eating salty food’, ‘Kimchi consumption’, ‘Korean soup or stew consumption’, ‘soy sauce or red pepper paste consumption’), and smoking status in men, and age, body weight, dietary behavior (‘salt preference’, ‘eating salty food’, ‘checking sodium content for processed foods’, ‘nut consumption’), and smoking status in women, respectively. When this model was tested in the external validation set, the mean bias between the measured and estimated 24-h urinary-sodium excretion from Bland-Altman plots was -1.92 (95% CI: -113, 110) mmol/d for men and -1.51 (95% CI: -90.6, 87.6) mmol/d for women. The cut-points of sodium intake calculated based on the equations were ≥4,000 mg/d for men and ≥3,500 mg/d for women, with 89.8 and 76.6% sensitivity and 29.3 and 64.2% specificity, respectively. In this study, a habitual 24-hour urinary-sodium-excretion-estimation model of normotensive Korean adults based on anthropometric and lifestyle factors was developed and showed feasibility for an asymptomatic population. PMID:29447201
Baranes, Adrien F; Oudeyer, Pierre-Yves; Gottlieb, Jacqueline
2014-01-01
Devising efficient strategies for exploration in large open-ended spaces is one of the most difficult computational problems of intelligent organisms. Because the available rewards are ambiguous or unknown during the exploratory phase, subjects must act in intrinsically motivated fashion. However, a vast majority of behavioral and neural studies to date have focused on decision making in reward-based tasks, and the rules guiding intrinsically motivated exploration remain largely unknown. To examine this question we developed a paradigm for systematically testing the choices of human observers in a free play context. Adult subjects played a series of short computer games of variable difficulty, and freely choose which game they wished to sample without external guidance or physical rewards. Subjects performed the task in three distinct conditions where they sampled from a small or a large choice set (7 vs. 64 possible levels of difficulty), and where they did or did not have the possibility to sample new games at a constant level of difficulty. We show that despite the absence of external constraints, the subjects spontaneously adopted a structured exploration strategy whereby they (1) started with easier games and progressed to more difficult games, (2) sampled the entire choice set including extremely difficult games that could not be learnt, (3) repeated moderately and high difficulty games much more frequently than was predicted by chance, and (4) had higher repetition rates and chose higher speeds if they could generate new sequences at a constant level of difficulty. The results suggest that intrinsically motivated exploration is shaped by several factors including task difficulty, novelty and the size of the choice set, and these come into play to serve two internal goals-maximize the subjects' knowledge of the available tasks (exploring the limits of the task set), and maximize their competence (performance and skills) across the task set.
Integration and software for thermal test of heat rate sensors. [space shuttle external tank
NASA Technical Reports Server (NTRS)
Wojciechowski, C. J.; Shrider, K. R.
1982-01-01
A minicomputer controlled radiant test facility is described which was developed and calibrated in an effort to verify analytical thermal models of instrumentation islands installed aboard the space shuttle external tank to measure thermal flight parameters during ascent. Software was provided for the facility as well as for development tests on the SRB actuator tail stock. Additional testing was conducted with the test facility to determine the temperature and heat flux rate and loads required to effect a change of color in the ET tank external paint. This requirement resulted from the review of photographs taken of the ET at separation from the orbiter which showed that 75% of the external tank paint coating had not changed color from its original white color. The paint on the remaining 25% of the tank was either brown or black, indicating that it had degraded due to heating or that the spray on form insulation had receded in these areas. The operational capability of the facility as well as the various tests which were conducted and their results are discussed.
Roustit, Christelle; Campoy, Eric; Chaix, Basile; Chauvin, Pierre
2010-07-01
Parental psychopathology is associated with increased psychosocial maladjustment in adolescents. We examined, from a psychosocial perspective, the association between parental psychological distress and psychosocial maladjustment in adolescents and assessed the mediating role of psychosocial covariates. This is a cross-sectional survey and the setting include representative sample of Quebec adolescents in 1999. The participants of the study include 13- and 16-year-old children (N = 2,346) in the Social and Health Survey of Quebec Children and Adolescents. The main outcome measures are internalizing disorders, externalizing disorders, substance use, and alcohol consumption. For statistical analysis, we used structural equation modeling to test for mediation. Internalizing and externalizing disorders were significantly associated with parental psychological distress, but not substance use or alcohol consumption. The higher the parental distress, the higher the risk of adolescent mental health disorders. The association between parental psychological distress and internalizing disorders was mediated by adolescent self-esteem, parental emotional support and extrafamilial social support. As for externalizing disorders, these variables only had an independent effect. In conclusion, A family's well being is a necessary condition for psychosocial adjustment in adolescence. Beyond the psychiatric approach, psychosocial considerations need to be taken into consideration to prevent negative mental health outcomes in children living in homes with distressed parents.
Campoy, Eric; Chaix, Basile; Chauvin, Pierre
2010-01-01
Abstract Parental psychopathology is associated with increased psychosocial maladjustment in adolescents. We examined, from a psychosocial perspective, the association between parental psychological distress and psychosocial maladjustment in adolescents and assessed the mediating role of psychosocial covariates. This is a cross-sectional survey and the setting include representative sample of Quebec adolescents in 1999. The participants of the study include 13- and 16-year-old children (N = 2,346) in the Social and Health Survey of Quebec Children and Adolescents. The main outcome measures are internalizing disorders, externalizing disorders, substance use, and alcohol consumption. For statistical analysis, we used structural equation modeling to test for mediation. Internalizing and externalizing disorders were significantly associated with parental psychological distress, but not substance use or alcohol consumption. The higher the parental distress, the higher the risk of adolescent mental health disorders. The association between parental psychological distress and internalizing disorders was mediated by adolescent self-esteem, parental emotional support and extrafamilial social support. As for externalizing disorders, these variables only had an independent effect. In conclusion, A family’s well being is a necessary condition for psychosocial adjustment in adolescence. Beyond the psychiatric approach, psychosocial considerations need to be taken into consideration to prevent negative mental health outcomes in children living in homes with distressed parents. PMID:20127380
Energy saving technologies of the decentralized ventilation of buildings
NASA Astrophysics Data System (ADS)
Mansurov, R. Sh; Rafalskaya, T. A.
2017-11-01
The growing aspiration to energy saving and efficiency of energy leads to necessity to build tight enough buildings. As a result of this the quantity of infiltration air appears insufficient for realization of necessary air exchange in. One of decisions of the given problem is development and application for ventilation of premises of the decentralized forced-air and exhaust systems (DFAES) with recuperative or regenerative heat-exchangers. For an estimation of efficiency of DFAES following basic parameters have been certain: factor of energy saving; factor of efficiency of energy; factor of a heat transfer; factor of an effective utilization of a surface of heat exchange. Were estimated temperature of forced air; actual speed of an air jet on an entrance in a served zone; actual noise level; the charge of external air. Tests of DFAES were spent in natural conditions at which DFAES influenced all set of factors both an external climate, and an internal microclimate of a premise, and also the arrangement on a wind side or behind wind side of a building, influence of surrounding building, fluctuation of temperature of external air is considered. Proceeding from results and the analysis of the lead researches recommendations have been developed for development and manufacture of new sample of DFAES.
Development of a relationship between external measurements and reinforcement stress
NASA Astrophysics Data System (ADS)
Brault, Andre; Hoult, Neil A.; Lees, Janet M.
2015-03-01
As many countries around the world face an aging infrastructure crisis, there is an increasing need to develop more accurate monitoring and assessment techniques for reinforced concrete structures. One of the challenges associated with assessing existing infrastructure is correlating externally measured parameters such as crack widths and surface strains with reinforcement stresses as this is dependent on a number of variables. The current research investigates how the use of distributed fiber optic sensors to measure reinforcement strain can be correlated with digital image correlation measurements of crack widths to relate external crack width measurements to reinforcement stresses. An initial set of experiments was undertaken involving a series of small-scale beam specimens tested in three-point bending with variable reinforcement properties. Relationships between crack widths and internal reinforcement strains were observed including that both the diameter and number of bars affected the measured maximum strain and crack width. A model that uses measured crack width to estimate reinforcement strain was presented and compared to the experimental results. The model was found to provide accurate estimates of load carrying capacity for a given crack width, however, the model was potentially less accurate when crack widths were used to estimate the experimental reinforcement strains. The need for more experimental data to validate the conclusions of this research was also highlighted.
Carrillo-Larco, Rodrigo M; Miranda, J Jaime; Gilman, Robert H; Medina-Lezama, Josefina; Chirinos-Pacheco, Julio A; Muñoz-Retamozo, Paola V; Smeeth, Liam; Checkley, William; Bernabe-Ortiz, Antonio
2017-11-29
Chronic Kidney Disease (CKD) represents a great burden for the patient and the health system, particularly if diagnosed at late stages. Consequently, tools to identify patients at high risk of having CKD are needed, particularly in limited-resources settings where laboratory facilities are scarce. This study aimed to develop a risk score for prevalent undiagnosed CKD using data from four settings in Peru: a complete risk score including all associated risk factors and another excluding laboratory-based variables. Cross-sectional study. We used two population-based studies: one for developing and internal validation (CRONICAS), and another (PREVENCION) for external validation. Risk factors included clinical- and laboratory-based variables, among others: sex, age, hypertension and obesity; and lipid profile, anemia and glucose metabolism. The outcome was undiagnosed CKD: eGFR < 60 ml/min/1.73m 2 . We tested the performance of the risk scores using the area under the receiver operating characteristic (ROC) curve, sensitivity, specificity, positive/negative predictive values and positive/negative likelihood ratios. Participants in both studies averaged 57.7 years old, and over 50% were females. Age, hypertension and anemia were strongly associated with undiagnosed CKD. In the external validation, at a cut-off point of 2, the complete and laboratory-free risk scores performed similarly well with a ROC area of 76.2% and 76.0%, respectively (P = 0.784). The best assessment parameter of these risk scores was their negative predictive value: 99.1% and 99.0% for the complete and laboratory-free, respectively. The developed risk scores showed a moderate performance as a screening test. People with a score of ≥ 2 points should undergo further testing to rule out CKD. Using the laboratory-free risk score is a practical approach in developing countries where laboratories are not readily available and undiagnosed CKD has significant morbidity and mortality.
Edelbring, Samuel; Wahlström, Rolf
2016-04-23
Students' self-regulated learning becomes essential with increased use of exploratory web-based activities such as virtual patients (VPs). The purpose was to investigate the interplay between students' self-regulated learning strategies and perceived benefit in VP learning activities. A cross-sectional study (n = 150) comparing students' study strategies and perceived benefit of a virtual patient learning activity in a clinical clerkship preparatory course. Teacher regulation varied among three settings and was classified from shared to strong. These settings were compared regarding their respective relations between regulation strategies and perceived benefit of the virtual patient activity. Self-regulation learning strategy was generally associated with perceived benefit of the VP activities (rho 0.27, p < 0.001), but was not true in all settings. The association was higher in the two strongly regulated settings. The external regulation strategy did generally associate weakly with perceived benefit (rho 0.17, p < 0.05) with large variations between settings. The flexible student-autonomous appeal of virtual patients should not lead to the dismissal of guidance and related course activities. External teacher and peer regulation seem to be productive for increasing learners' perceived benefit. Awareness of the interplay among teacher regulation (external) and various study strategies can increase the value of flexible web-based learning resources to students.
Screening experiments of ecstasy street samples using near infrared spectroscopy.
Sondermann, N; Kovar, K A
1999-12-20
Twelve different sets of confiscated ecstasy samples were analysed applying both near infrared spectroscopy in reflectance mode (1100-2500 nm) and high-performance liquid chromatography (HPLC). The sets showed a large variance in composition. A calibration data set was generated based on the theory of factorial designs. It contained 221 N-methyl-3,4-methylenedioxyamphetamine (MDMA) samples, 167 N-ethyl-3,4-methylenedioxyamphetamine (MDE), 111 amphetamine and 106 samples without a controlled substance, which will be called placebo samples thereafter. From this data set, PLS-1 models were calculated and were successfully applied for validation of various external laboratory test sets. The transferability of these results to confiscated tablets is demonstrated here. It is shown that differentiation into placebo, amphetamine and ecstasy samples is possible. Analysis of intact tablets is practicable. However, more reliable results are obtained from pulverised samples. This is due to ill-defined production procedures. The use of mathematically pretreated spectra improves the prediction quality of all the PLS-1 models studied. It is possible to improve discrimination between MDE and MDMA with the help of a second model based on raw spectra. Alternative strategies are briefly discussed.
Artificial Pancreas Device Systems for the Closed-Loop Control of Type 1 Diabetes
Trevitt, Sara; Simpson, Sue; Wood, Annette
2015-01-01
Background: Closed-loop artificial pancreas device (APD) systems are externally worn medical devices that are being developed to enable people with type 1 diabetes to regulate their blood glucose levels in a more automated way. The innovative concept of this emerging technology is that hands-free, continuous, glycemic control can be achieved by using digital communication technology and advanced computer algorithms. Methods: A horizon scanning review of this field was conducted using online sources of intelligence to identify systems in development. The systems were classified into subtypes according to their level of automation, the hormonal and glycemic control approaches used, and their research setting. Results: Eighteen closed-loop APD systems were identified. All were being tested in clinical trials prior to potential commercialization. Six were being studied in the home setting, 5 in outpatient settings, and 7 in inpatient settings. It is estimated that 2 systems may become commercially available in the EU by the end of 2016, 1 during 2017, and 2 more in 2018. Conclusions: There are around 18 closed-loop APD systems progressing through early stages of clinical development. Only a few of these are currently in phase 3 trials and in settings that replicate real life. PMID:26589628
NASA Astrophysics Data System (ADS)
Kalanov, Temur Z.
2003-04-01
A new theory of space is suggested. It represents the new point of view which has arisen from the critical analysis of the foundations of physics (in particular the theory of relativity and quantum mechanics), mathematics, cosmology and philosophy. The main idea following from the analysis is that the concept of movement represents a key to understanding of the essence of space. The starting-point of the theory is represented by the following philosophical (dialectical materialistic) principles. (a) The principle of the materiality (of the objective reality) of the Nature: the Nature (the Universe) is a system (a set) of material objects (particles, bodies, fields); each object has properties, features, and the properties, the features are inseparable characteristics of material object and belong only to material object. (b) The principle of the existence of material object: an object exists as the objective reality, and movement is a form of existence of object. (c) The principle (definition) of movement of object: the movement is change (i.e. transition of some states into others) in general; the movement determines a direction, and direction characterizes the movement. (d) The principle of existence of time: the time exists as the parameter of the system of reference. These principles lead to the following statements expressing the essence of space. (1) There is no space in general, and there exist space only as a form of existence of the properties and features of the object. It means that the space is a set of the measures of the object (the measure is the philosophical category meaning unity of the qualitative and quantitative determinacy of the object). In other words, the space of the object is a set of the states of the object. (2) The states of the object are manifested only in a system of reference. The main informational property of the unitary system researched physical object + system of reference is that the system of reference determines (measures, calculates) the parameters of the subsystem researched physical object (for example, the coordinates of the object M); the parameters characterize the system of reference (for example, the system of coordinates S). (3) Each parameter of the object is its measure. Total number of the mutually independent parameters of the object is called dimension of the space of the object. (4) The set of numerical values (i.e. the range, the spectrum) of each parameter is the subspace of the object. (The coordinate space, the momentum space and the energy space are examples of the subspaces of the object). (5) The set of the parameters of the object is divided into two non intersecting (opposite) classes: the class of the internal parameters and the class of the non internal (i.e. external) parameters. The class of the external parameters is divided into two non intersecting (opposite) subclasses: the subclass of the absolute parameters (characterizing the form, the sizes of the object) and the subclass of the non absolute (relative) parameters (characterizing the position, the coordinates of the object). (6) Set of the external parameters forms the external space of object. It is called geometrical space of object. (7) Since a macroscopic object has three mutually independent sizes, the dimension of its external absolute space is equal to three. Consequently, the dimension of its external relative space is also equal to three. Thus, the total dimension of the external space of the macroscopic object is equal to six. (8) In general case, the external absolute space (i.e. the form, the sizes) and the external relative space (i.e. the position, the coordinates) of any object are mutually dependent because of influence of a medium. The geometrical space of such object is called non Euclidean space. If the external absolute space and the external relative space of some object are mutually independent, then the external relative space of such object is the homogeneous and isotropic geometrical space. It is called Euclidean space of the object. Consequences: (i) the question of true geometry of the Universe is incorrect; (ii) the theory of relativity has no physical meaning.
Bajaj, Jasmohan S; Heuman, Douglas M; Sterling, Richard K; Sanyal, Arun J; Siddiqui, Muhammad; Matherly, Scott; Luketic, Velimir; Stravitz, R Todd; Fuchs, Michael; Thacker, Leroy R; Gilles, HoChong; White, Melanie B; Unser, Ariel; Hovermale, James; Gavis, Edith; Noble, Nicole A; Wade, James B
2014-01-01
Background & Aims Detection of covert hepatic encephalopathy (CHE) is difficult but point of care testing could increase rates of diagnosis. We aimed to validate the ability of the smartphone app EncephalApp, a streamlined version of Stroop App, to detect CHE. We evaluated face validity, test–retest reliability, and external validity. Methods Patients with cirrhosis (n=167; 38% with overt HE [OHE]; mean age, 55 years; mean model for end-stage liver disease score, 12) and controls (n=114) were each given a paper and pencil cognitive battery (standard) along with EncephalApp. EncephalApp has Off and On states; results measured were: OffTime, OnTime, OffTime+OnTime, and number of runs required to complete 5 off and on runs. Thirty-six patients with cirrhosis underwent driving simulation tests, and EncephalApp results were correlated with results. Test–retest reliability was analyzed in a subgroup of patients. The test was performed before and after transjugular intra-hepatic portosystemic shunt placement, before and after correction for hyponatremia, to determine external validity. Results All patients with cirrhosis performed worse on paper and pencil and EncephalApp tests than controls. Patients with cirrhosis and OHE performed worse than those without OHE. Age-dependent EncephalApp cut-offs (younger or older than 45 years) were set. An OffTime+OnTime value of >190 seconds identified all patients with CHE with an area under the receiver operator characteristic (AUROC) value of 0.91; the AUROC value was 0.88 for diagnosis of CHE in those without OHE. EncephalApp times correlated with crashes and illegal turns in driving simulation tests. Test–retest reliability was high (intra-class coefficient, 0.83) among 30 patients retested 1–3 months apart. OffTime+OnTime increased significantly (206 vs 255, P=.007) among 10 patients retested 33±7 days after transjugular intra-hepatic portosystemic shunt placement. OffTime+OnTime decreased significantly (242 vs 225, P=.03) in 7 patients tested before and after correction for hyponatremia (126±3 to 132±4 meq/L, P=.01), 10±5 days apart. Conclusions A smartphone app called EncephalApp has good face validity, test–retest reliability, and external validity for the diagnosis of CHE. PMID:24846278
A RE-AIM evaluation of theory-based physical activity interventions.
Antikainen, Iina; Ellis, Rebecca
2011-04-01
Although physical activity interventions have been shown to effectively modify behavior, little research has examined the potential of these interventions for adoption in real-world settings. The purpose of this literature review was to evaluate the external validity of 57 theory-based physical activity interventions using the RE-AIM framework. The physical activity interventions included were more likely to report on issues of internal, rather than external validity and on individual, rather than organizational components of the RE-AIM framework, making the translation of many interventions into practice difficult. Furthermore, most studies included motivated, healthy participants, thus reducing the generalizability of the interventions to real-world settings that provide services to more diverse populations. To determine if a given intervention is feasible and effective in translational research, more information should be reported about the factors that affect external validity.
Comparing and Validating Machine Learning Models for Mycobacterium tuberculosis Drug Discovery.
Lane, Thomas; Russo, Daniel P; Zorn, Kimberley M; Clark, Alex M; Korotcov, Alexandru; Tkachenko, Valery; Reynolds, Robert C; Perryman, Alexander L; Freundlich, Joel S; Ekins, Sean
2018-04-26
Tuberculosis is a global health dilemma. In 2016, the WHO reported 10.4 million incidences and 1.7 million deaths. The need to develop new treatments for those infected with Mycobacterium tuberculosis ( Mtb) has led to many large-scale phenotypic screens and many thousands of new active compounds identified in vitro. However, with limited funding, efforts to discover new active molecules against Mtb needs to be more efficient. Several computational machine learning approaches have been shown to have good enrichment and hit rates. We have curated small molecule Mtb data and developed new models with a total of 18,886 molecules with activity cutoffs of 10 μM, 1 μM, and 100 nM. These data sets were used to evaluate different machine learning methods (including deep learning) and metrics and to generate predictions for additional molecules published in 2017. One Mtb model, a combined in vitro and in vivo data Bayesian model at a 100 nM activity yielded the following metrics for 5-fold cross validation: accuracy = 0.88, precision = 0.22, recall = 0.91, specificity = 0.88, kappa = 0.31, and MCC = 0.41. We have also curated an evaluation set ( n = 153 compounds) published in 2017, and when used to test our model, it showed the comparable statistics (accuracy = 0.83, precision = 0.27, recall = 1.00, specificity = 0.81, kappa = 0.36, and MCC = 0.47). We have also compared these models with additional machine learning algorithms showing Bayesian machine learning models constructed with literature Mtb data generated by different laboratories generally were equivalent to or outperformed deep neural networks with external test sets. Finally, we have also compared our training and test sets to show they were suitably diverse and different in order to represent useful evaluation sets. Such Mtb machine learning models could help prioritize compounds for testing in vitro and in vivo.
Zhao, Wei; Kaguelidou, Florentia; Biran, Valérie; Zhang, Daolun; Allegaert, Karel; Capparelli, Edmund V; Holford, Nick; Kimura, Toshimi; Lo, Yoke-Lin; Peris, José-Esteban; Thomson, Alison; Anker, John N; Fakhoury, May; Jacqz-Aigrain, Evelyne
2013-01-01
Aims Vancomycin is one of the most evaluated antibiotics in neonates using modeling and simulation approaches. However no clear consensus on optimal dosing has been achieved. The objective of the present study was to perform an external evaluation of published models, in order to test their predictive performances in an independent dataset and to identify the possible study-related factors influencing the transferability of pharmacokinetic models to different clinical settings. Method Published neonatal vancomycin pharmacokinetic models were screened from the literature. The predictive performance of six models was evaluated using an independent dataset (112 concentrations from 78 neonates). The evaluation procedures used simulation-based diagnostics [visual predictive check (VPC) and normalized prediction distribution errors (NPDE)]. Results Differences in predictive performances of models for vancomycin pharmacokinetics in neonates were found. The mean of NPDE for six evaluated models were 1.35, −0.22, −0.36, 0.24, 0.66 and 0.48, respectively. These differences were explained, at least partly, by taking into account the method used to measure serum creatinine concentrations. The adult conversion factor of 1.3 (enzymatic to Jaffé) was tested with an improvement in the VPC and NPDE, but it still needs to be evaluated and validated in neonates. Differences were also identified between analytical methods for vancomycin. Conclusion The importance of analytical techniques for serum creatinine concentrations and vancomycin as predictors of vancomycin concentrations in neonates have been confirmed. Dosage individualization of vancomycin in neonates should consider not only patients' characteristics and clinical conditions, but also the methods used to measure serum creatinine and vancomycin. PMID:23148919
Gupte, Amol; Buolamwini, John K
2009-01-15
3D-QSAR (CoMFA and CoMSIA) studies were performed on human equlibrative nucleoside transporter (hENT1) inhibitors displaying K(i) values ranging from 10,000 to 0.7nM. Both CoMFA and CoMSIA analysis gave reliable models with q2 values >0.50 and r2 values >0.92. The models have been validated for their stability and robustness using group validation and bootstrapping techniques and for their predictive abilities using an external test set of nine compounds. The high predictive r2 values of the test set (0.72 for CoMFA model and 0.74 for CoMSIA model) reveals that the models can prove to be a useful tool for activity prediction of newly designed nucleoside transporter inhibitors. The CoMFA and CoMSIA contour maps identify features important for exhibiting good binding affinities at the transporter, and can thus serve as a useful guide for the design of potential equilibrative nucleoside transporter inhibitors.
Neural network pattern recognition of thermal-signature spectra for chemical defense
NASA Astrophysics Data System (ADS)
Carrieri, Arthur H.; Lim, Pascal I.
1995-05-01
We treat infrared patterns of absorption or emission by nerve and blister agent compounds (and simulants of this chemical group) as features for the training of neural networks to detect the compounds' liquid layers on the ground or their vapor plumes during evaporation by external heating. Training of a four-layer network architecture is composed of a backward-error-propagation algorithm and a gradient-descent paradigm. We conduct testing by feed-forwarding preprocessed spectra through the network in a scaled format consistent with the structure of the training-data-set representation. The best-performance weight matrix (spectral filter) evolved from final network training and testing with software simulation trials is electronically transferred to a set of eight artificial intelligence integrated circuits (ICs') in specific modular form (splitting of weight matrices). This form makes full use of all input-output IC nodes. This neural network computer serves an important real-time detection function when it is integrated into pre-and postprocessing data-handling units of a tactical prototype thermoluminescence sensor now under development at the Edgewood Research, Development, and Engineering Center.
Ribeiro, Taisa Pereira Piacentini; Manarin, Flávia Giovana; Borges de Melo, Eduardo
2018-05-30
To address the rising global demand for food, it is necessary to search for new herbicides that can control resistant weeds. We performed a 2D-quantitative structure-activity relationship (QSAR) study to predict compounds with photosynthesis-inhibitory activity. A data set of 44 compounds (quinolines and naphthalenes), which are described as photosynthetic electron transport (PET) inhibitors, was used. The obtained model was approved in internal and external validation tests. 2D Similarity-based virtual screening was performed and 64 compounds were selected from the ZINC database. By using the VEGA QSAR software, 48 compounds were shown to have potential toxic effects (mutagenicity and carcinogenicity). Therefore, the model was also tested using a set of 16 molecules obtained by a similarity search of the ZINC database. Six compounds showed good predicted inhibition of PET. The obtained model shows potential utility in the design of new PET inhibitors, and the hit compounds found by virtual screening are novel bicyclic scaffolds of this class. Copyright © 2018 Elsevier Inc. All rights reserved.
Reconceptualising the external validity of discrete choice experiments.
Lancsar, Emily; Swait, Joffre
2014-10-01
External validity is a crucial but under-researched topic when considering using discrete choice experiment (DCE) results to inform decision making in clinical, commercial or policy contexts. We present the theory and tests traditionally used to explore external validity that focus on a comparison of final outcomes and review how this traditional definition has been empirically tested in health economics and other sectors (such as transport, environment and marketing) in which DCE methods are applied. While an important component, we argue that the investigation of external validity should be much broader than a comparison of final outcomes. In doing so, we introduce a new and more comprehensive conceptualisation of external validity, closely linked to process validity, that moves us from the simple characterisation of a model as being or not being externally valid on the basis of predictive performance, to the concept that external validity should be an objective pursued from the initial conceptualisation and design of any DCE. We discuss how such a broader definition of external validity can be fruitfully used and suggest innovative ways in which it can be explored in practice.
Kal, E. C.; van der Kamp, J.; Houdijk, H.; Groet, E.; van Bennekom, C. A. M.; Scherder, E. J. A.
2015-01-01
Dual-task performance is often impaired after stroke. This may be resolved by enhancing patients’ automaticity of movement. This study sets out to test the constrained action hypothesis, which holds that automaticity of movement is enhanced by triggering an external focus (on movement effects), rather than an internal focus (on movement execution). Thirty-nine individuals with chronic, unilateral stroke performed a one-leg-stepping task with both legs in single- and dual-task conditions. Attentional focus was manipulated with instructions. Motor performance (movement speed), movement automaticity (fluency of movement), and dual-task performance (dual-task costs) were assessed. The effects of focus on movement speed, single- and dual-task movement fluency, and dual-task costs were analysed with generalized estimating equations. Results showed that, overall, single-task performance was unaffected by focus (p = .341). Regarding movement fluency, no main effects of focus were found in single- or dual-task conditions (p’s ≥ .13). However, focus by leg interactions suggested that an external focus reduced movement fluency of the paretic leg compared to an internal focus (single-task conditions: p = .068; dual-task conditions: p = .084). An external focus also tended to result in inferior dual-task performance (β = -2.38, p = .065). Finally, a near-significant interaction (β = 2.36, p = .055) suggested that dual-task performance was more constrained by patients’ attentional capacity in external focus conditions. We conclude that, compared to an internal focus, an external focus did not result in more automated movements in chronic stroke patients. Contrary to expectations, trends were found for enhanced automaticity with an internal focus. These findings might be due to patients’ strong preference to use an internal focus in daily life. Future work needs to establish the more permanent effects of learning with different attentional foci on re-automating motor control after stroke. PMID:26317437
Aryanto, Kadek Y E; Broekema, André; Oudkerk, Matthijs; van Ooijen, Peter M A
2012-01-01
To present an adapted Clinical Trial Processor (CTP) test set-up for receiving, anonymising and saving Digital Imaging and Communications in Medicine (DICOM) data using external input from the original database of an existing clinical study information system to guide the anonymisation process. Two methods are presented for an adapted CTP test set-up. In the first method, images are pushed from the Picture Archiving and Communication System (PACS) using the DICOM protocol through a local network. In the second method, images are transferred through the internet using the HTTPS protocol. In total 25,000 images from 50 patients were moved from the PACS, anonymised and stored within roughly 2 h using the first method. In the second method, an average of 10 images per minute were transferred and processed over a residential connection. In both methods, no duplicated images were stored when previous images were retransferred. The anonymised images are stored in appropriate directories. The CTP can transfer and process DICOM images correctly in a very easy set-up providing a fast, secure and stable environment. The adapted CTP allows easy integration into an environment in which patient data are already included in an existing information system.
External Long-Duration Materials Instrument Research Observatory
NASA Astrophysics Data System (ADS)
Engelhardt, J. P.; Heath, K.
2018-02-01
The External Long-duration Materials and Instrument Research Observatory (ELMIRO) is a commercial facility that will allow for continuous and repeatable external testing on the Deep Space Gateway of materials, electronics/instruments for future deep space spacecraft.
A Quantitative Model for the Prediction of Sooting Tendency from Molecular Structure
DOE Office of Scientific and Technical Information (OSTI.GOV)
St. John, Peter C.; Kairys, Paul; Das, Dhrubajyoti D.
Particulate matter emissions negatively affect public health and global climate, yet newer fuel-efficient gasoline direct injection engines tend to produce more soot than their port-fuel injection counterparts. Fortunately, the search for sustainable biomass-based fuel blendstocks provides an opportunity to develop fuels that suppress soot formation in more efficient engine designs. However, as emissions tests are experimentally cumbersome and the search space for potential bioblendstocks is vast, new techniques are needed to estimate the sooting tendency of a diverse range of compounds. In this study, we develop a quantitative structure-activity relationship (QSAR) model of sooting tendency based on the experimental yieldmore » sooting index (YSI), which ranks molecules on a scale from n-hexane, 0, to benzene, 100. The model includes a rigorously defined applicability domain, and the predictive performance is checked using both internal and external validation. Model predictions for compounds in the external test set had a median absolute error of ~3 YSI units. An investigation of compounds that are poorly predicted by the model lends new insight into the complex mechanisms governing soot formation. Predictive models of soot formation can therefore be expected to play an increasingly important role in the screening and development of next-generation biofuels.« less
A Quantitative Model for the Prediction of Sooting Tendency from Molecular Structure
St. John, Peter C.; Kairys, Paul; Das, Dhrubajyoti D.; ...
2017-07-24
Particulate matter emissions negatively affect public health and global climate, yet newer fuel-efficient gasoline direct injection engines tend to produce more soot than their port-fuel injection counterparts. Fortunately, the search for sustainable biomass-based fuel blendstocks provides an opportunity to develop fuels that suppress soot formation in more efficient engine designs. However, as emissions tests are experimentally cumbersome and the search space for potential bioblendstocks is vast, new techniques are needed to estimate the sooting tendency of a diverse range of compounds. In this study, we develop a quantitative structure-activity relationship (QSAR) model of sooting tendency based on the experimental yieldmore » sooting index (YSI), which ranks molecules on a scale from n-hexane, 0, to benzene, 100. The model includes a rigorously defined applicability domain, and the predictive performance is checked using both internal and external validation. Model predictions for compounds in the external test set had a median absolute error of ~3 YSI units. An investigation of compounds that are poorly predicted by the model lends new insight into the complex mechanisms governing soot formation. Predictive models of soot formation can therefore be expected to play an increasingly important role in the screening and development of next-generation biofuels.« less
Yokota, M; Kusama, M; Matsuki, N; Ono, S
2013-12-01
External experts play an important role in shaping regulatory decisions in the new drug review process in the United States, Europe and Japan. No rigorous study has been performed addressing how and to what extent external experts, in contrast to internal reviewers in the agency, influence the regulatory decisions during new drug reviews. We examined their contributions in Japanese regulatory reviews in contrast to the internal reviewers, focusing on the labelling decision on therapeutic indications. With the data set of 219 new molecular entities (NMEs) approved in Japan from 2000 to 2009, we observed how proposed indications in labelling were modified in a stepwise manner during the review process and conducted multinomial logistic analysis to examine the possible mechanism behind. We found that interim assessment of indications by the internal reviewers was modified substantially by the influence of the external experts in about 20% of the 219 NMEs. Our analysis suggested that internal reviewers provided their opinion mainly based on strict review discipline, whereas external experts added flexibility and reality to their reviews. Our analysis revealed different evaluations between internal reviewers and external experts during regulatory discussions in new drug reviews and how the external panel contributes to changing internal decisions. This study provides a new and quantitative approach to better label setting by emphasizing the contributions of each stakeholder in new drug reviews, which would improve the efficiency, quality and transparency of new drug reviews to enhance public health. © 2013 John Wiley & Sons Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shervin, Shahab; Asadirad, Mojtaba; Materials Science and Engineering Program, University of Houston, Houston, Texas 77204
This paper presents strain-effect transistors (SETs) based on flexible III-nitride high-electron-mobility transistors (HEMTs) through theoretical calculations. We show that the electronic band structures of InAlGaN/GaN thin-film heterostructures on flexible substrates can be modified by external bending with a high degree of freedom using polarization properties of the polar semiconductor materials. Transfer characteristics of the HEMT devices, including threshold voltage and transconductance, are controlled by varied external strain. Equilibrium 2-dimensional electron gas (2DEG) is enhanced with applied tensile strain by bending the flexible structure with the concave-side down (bend-down condition). 2DEG density is reduced and eventually depleted with increasing compressive strainmore » in bend-up conditions. The operation mode of different HEMT structures changes from depletion- to enchantment-mode or vice versa depending on the type and magnitude of external strain. The results suggest that the operation modes and transfer characteristics of HEMTs can be engineered with an optimum external bending strain applied in the device structure, which is expected to be beneficial for both radio frequency and switching applications. In addition, we show that drain currents of transistors based on flexible InAlGaN/GaN can be modulated only by external strain without applying electric field in the gate. The channel conductivity modulation that is obtained by only external strain proposes an extended functional device, gate-free SETs, which can be used in electro-mechanical applications.« less
Systems Perspectives on External Quality Assurance: Implications for Micro-States
ERIC Educational Resources Information Center
Houston, Don; Maniku, Ahmed Ali
2005-01-01
Quality assurance in higher education is a mess: the "problem" of quality is embedded in complex sets of interacting issues that are of concern to many and varied stakeholders. Developing higher education systems that have responded to issues of quality through a "best practice" model of external quality assurance has produced…
The Practice of Educational Evaluation: A View from the Inside.
ERIC Educational Resources Information Center
Jolly, S. Jean; Gramenz, Gary W.
The literature on the practice of educational evaluation is reviewed, and internal and external evaluations in a school setting are compared. The paper states that the typical external evaluation is conducted as if school districts were rational organizations, a view which permeated 19th century evaluation activities. The internal evaluator, on…
ERIC Educational Resources Information Center
McDonald, Christin A.; Lopata, Christopher; Donnelly, James P.; Thomeer, Marcus L.; Rodgers, Jonathan D.; Jordan, Allyson K.
2016-01-01
Assessment of clinical symptoms requires information from multiple informants. Discrepancies between informants' ratings can have significant implications in school settings (e.g., access to services, treatment planning, progress monitoring). This study examined parent-teacher discrepancies for ratings of internalizing and externalizing symptoms,…
ERIC Educational Resources Information Center
Mrug, Sylvie; Windle, Michael
2010-01-01
Background: Violence exposure within each setting of community, school, or home has been linked with internalizing and externalizing problems. Although many children experience violence in multiple contexts, the effects of such cross-contextual exposure have not been studied. This study addresses this gap by examining independent and interactive…
Liu, Jianghong; Raine, Adrian; Wuerker, Anne; Venables, Peter H.; Mednick, Sarnoff
2012-01-01
Prior studies have shown that birth complications interact with psychosocial risk factors in predisposing to increased externalizing behavior in childhood and criminal behavior in adulthood. However, little is known about the direct relationship between birth complications and externalizing behavior. Furthermore, the mechanism by which the birth complications predispose to externalizing behavior is not well explored. This study aims to assess whether birth complications predispose to early adolescent externalizing behavior and to test whether Intelligence Quotient (IQ) mediates relationships between predictor and outcome variables. We used data from a prospective, longitudinal birth cohort of 1,795 3-year-old boys and girls from Mauritius to test hypotheses. Birth complications were assessed from hospital record data, malnutrition from a pediatric exam at age 3 years, psychosocial adversity from parental interviews at age 3 years, and externalizing behavior problems from parental ratings at age 11 years. We found that babies with birth complications are more likely to develop externalizing behavior problems at age 11. Low IQ was associated with birth complications and was found to mediate the link between early predictors and later externalizing behavior. These prospective, longitudinal findings have potential clinical implications for the identification of early adolescent externalizing behavior and for public health attempts to prevent the occurrence of child externalizing behavior problems. PMID:22485069
Comparison of range of motion tests with throwing kinematics in elite team handball players.
van den Tillaar, Roland
2016-10-01
The aim of this study was to compare the active and passive range of motion (ROM) of the glenohumeral external rotation with the maximal external rotation and throwing performance during different throws with different wind-up techniques in elite team handball players. Twenty-two elite team handball players participated in the study in which the maximal ball release velocity and maximal external rotation during standing, with run-up and jump throws with two types of wind-ups were measured together with the maximal active and passive glenohumeral ROM of the external rotation, lying supine on a bench. Higher maximal external rotation was found during the throws with the whip-like wind-up in comparison to circular-like wind-up throws together with a lower external rotation during the active ROM test. No correlations were found between the ROM of the external rotation with the maximal ball release velocity and the maximal external rotation measured during the throws. It was concluded that ROM of the external rotation measured on the bench does not give any information about the maximal throwing performance or the external rotation angle during throwing and therefore cannot be used to identify potential fast throwers or injuries in elite team handball players.
Franken, Aart; Keijsers, Loes; Dijkstra, Jan Kornelis; Ter Bogt, Tom
2017-08-01
Music Marker Theory posits that music is relevant for the structuring of peer groups and that rock, urban, or dance music preferences relate to externalizing behavior. The present study tested these hypotheses, by investigating the role of music preference similarity in friendship selection and the development of externalizing behavior, while taking the effects of friends' externalizing behavior into account. Data were used from the first three waves of the SNARE (Social Network Analysis of Risk behavior in Early adolescence) study (N = 1144; 50% boys; M age = 12.7; SD = 0.47), including students who entered the first-year of secondary school. Two hypotheses were tested. First, adolescents were expected to select friends based both on a similarity in externalizing behavior and music genre preference. Second, a preference for rock, urban, or dance, music types was expected to predict the development of externalizing behavior, even when taking friends' influence on externalizing behavior into account. Stochastic Actor-Based Modeling indicated that adolescents select their friends based on both externalizing behavior and highbrow music preference. Moreover, both friends' externalizing behavior and a preference for dance music predicted the development of externalizing behavior. Intervention programs might focus on adolescents with dance music preferences.
Rogier, Eric; Plucinski, Mateusz; Lucchi, Naomi; Mace, Kimberly; Chang, Michelle; Lemoine, Jean Frantz; Candrinho, Baltazar; Colborn, James; Dimbu, Rafael; Fortes, Filomeno; Udhayakumar, Venkatachalam; Barnwell, John
2017-01-01
Detection of histidine-rich protein 2 (HRP2) from the malaria parasite Plasmodium falciparum provides evidence for active or recent infection, and is utilized for both diagnostic and surveillance purposes, but current laboratory immunoassays for HRP2 are hindered by low sensitivities and high costs. Here we present a new HRP2 immunoassay based on antigen capture through a bead-based system capable of detecting HRP2 at sub-picogram levels. The assay is highly specific and cost-effective, allowing fast processing and screening of large numbers of samples. We utilized the assay to assess results of HRP2-based rapid diagnostic tests (RDTs) in different P. falciparum transmission settings, generating estimates for true performance in the field. Through this method of external validation, HRP2 RDTs were found to perform well in the high-endemic areas of Mozambique and Angola with 86.4% and 73.9% of persons with HRP2 in their blood testing positive by RDTs, respectively, and false-positive rates of 4.3% and 0.5%. However, in the low-endemic setting of Haiti, only 14.5% of persons found to be HRP2 positive by the bead assay were RDT positive. Additionally, 62.5% of Haitians showing a positive RDT test had no detectable HRP2 by the bead assay, likely indicating that these were false positive tests. In addition to RDT validation, HRP2 biomass was assessed for the populations in these different settings, and may provide an additional metric by which to estimate P. falciparum transmission intensity and measure the impact of interventions. PMID:28192523
1987-07-01
A forward segment is being lowered into the Transient Pressure Test Article (TPTA) test stand at the Marshall Space Flight Center (MSFC) east test area. The TPTA test stand, 14-feet wide, 27-feet long, and 33-feet high, was built in 1987 to provide data to verify the sealing capability of the redesign solid rocket motor (SRM) field and nozzle joints. The test facility applies pressure, temperature, and external loads to a short stack of solid rocket motor hardware. The simulated SRM ignition pressure and temperature transients are achieved by firing a small amount of specially configured solid propellant. The pressure transient is synchronized with external programmable dynamic loads that simulate lift off loads at the external tank attach points. Approximately one million pounds of dead weight on top of the test article simulates the weight of the other Shuttle elements.
1987-07-01
A forward segment is being lowered into the Transient Pressure Test Article (TPTA) test stand at thw Marshall Space Flight Center (MSFC) east test area. The TPTA test stand, 14-feet wide, 27-feet long, and 33-feet high, was built in 1987 to provide data to verify the sealing capability of the redesign solid rocket motor (SRM) field and nozzle joints. The test facility applies pressure, temperature, and external loads to a short stack of solid rocket motor hardware. The simulated SRM ignition pressure and temperature transients are achieved by firing a small amount of specially configured solid propellant. The pressure transient is synchronized with external programmable dynamic loads that simulate lift off loads at the external tank attach points. Approximately one million pounds of dead weight on top of the test article simulates the weight of the other Shuttle elements.
Effect of external jet-flow deflector geometry on OTW aero-acoustic characteristics
NASA Technical Reports Server (NTRS)
Vonglahn, U.; Groesbeck, D.
1976-01-01
The effect of geometry variations in the design of external deflectors for use with over-the-wing (OTW) configurations was studied at model scale and subsonic jet velocities. Included in the variations were deflector size and angle as well as wing size and flap setting. A conical nozzle (5.2-cm diameter) mounted at 0.1 chord above and downstream of the wing leading edges was used. The data indicate that external deflectors provide satisfactory takeoff and approach aerodynamic performance and acoustic characteristics for OTW configurations. These characteristics together with expected good cruise aerodynamics, since external deflectors are storable, may provide optimum OTW design configurations.
Static Internal Performance of a Two-Dimensional Convergent-Divergent Nozzle with External Shelf
NASA Technical Reports Server (NTRS)
Lamb, Milton; Taylor, John G.; Frassinelli, Mark C.
1996-01-01
An investigation was conducted in the static test facility of the Langley 16-Foot Transonic Tunnel to determine the internal performance of a two-dimensional convergent-divergent nozzle. The nozzle design was tested with dry and afterburning throat areas, which represent different power settings and three expansion ratios. For each of these configurations, three trailing-edge geometries were tested. The baseline geometry had a straight trailing edge. Two different shaping techniques were applied to the baseline nozzle design to reduce radar observables: the scarfed design and the sawtooth design. A flat plate extended downstream of the lower divergent flap trailing edge parallel to the model centerline to form a shelf-like expansion surface. This shelf was designed to shield the plume from ground observation (infrared radiation (IR) signature suppression). The shelf represents the part of the aircraft structure that might be present in an installed configuration. These configurations were tested at nozzle pressure ratios from 2.0 to 12.0.
Debray, Thomas P A; Vergouwe, Yvonne; Koffijberg, Hendrik; Nieboer, Daan; Steyerberg, Ewout W; Moons, Karel G M
2015-03-01
It is widely acknowledged that the performance of diagnostic and prognostic prediction models should be assessed in external validation studies with independent data from "different but related" samples as compared with that of the development sample. We developed a framework of methodological steps and statistical methods for analyzing and enhancing the interpretation of results from external validation studies of prediction models. We propose to quantify the degree of relatedness between development and validation samples on a scale ranging from reproducibility to transportability by evaluating their corresponding case-mix differences. We subsequently assess the models' performance in the validation sample and interpret the performance in view of the case-mix differences. Finally, we may adjust the model to the validation setting. We illustrate this three-step framework with a prediction model for diagnosing deep venous thrombosis using three validation samples with varying case mix. While one external validation sample merely assessed the model's reproducibility, two other samples rather assessed model transportability. The performance in all validation samples was adequate, and the model did not require extensive updating to correct for miscalibration or poor fit to the validation settings. The proposed framework enhances the interpretation of findings at external validation of prediction models. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.
Made-to-measure modelling of observed galaxy dynamics
NASA Astrophysics Data System (ADS)
Bovy, Jo; Kawata, Daisuke; Hunt, Jason A. S.
2018-01-01
Amongst dynamical modelling techniques, the made-to-measure (M2M) method for modelling steady-state systems is amongst the most flexible, allowing non-parametric distribution functions in complex gravitational potentials to be modelled efficiently using N-body particles. Here, we propose and test various improvements to the standard M2M method for modelling observed data, illustrated using the simple set-up of a one-dimensional harmonic oscillator. We demonstrate that nuisance parameters describing the modelled system's orientation with respect to the observer - e.g. an external galaxy's inclination or the Sun's position in the Milky Way - as well as the parameters of an external gravitational field can be optimized simultaneously with the particle weights. We develop a method for sampling from the high-dimensional uncertainty distribution of the particle weights. We combine this in a Gibbs sampler with samplers for the nuisance and potential parameters to explore the uncertainty distribution of the full set of parameters. We illustrate our M2M improvements by modelling the vertical density and kinematics of F-type stars in Gaia DR1. The novel M2M method proposed here allows full probabilistic modelling of steady-state dynamical systems, allowing uncertainties on the non-parametric distribution function and on nuisance parameters to be taken into account when constraining the dark and baryonic masses of stellar systems.
Weaver, W D; Sutherland, K; Wirkus, M J; Bachman, R
1989-02-01
During the 1986 World's Exposition held in Vancouver, British Columbia, the types and frequencies of emergency medical problems were assessed. The average number of patients seeking care was 3.93 +/- 0.95 per 1,000 visitors (daily range, 1.94 to 6.8). Patient loads were linearly related to gate attendance, but the correlation was imperfect (P less than .001, r = .63). Only 4.4% of patients evaluated on site by nurses and paramedics were referred for additional testing and treatment: of these patients, 30% had suspected serious musculoskeletal injury, 16% had abdominal pain, and 25% had complaints of chest pain, dizziness, or loss of consciousness. Lay employees (security personnel) were trained to use automatic external defibrillators. There were six cardiac arrests (0.3 per million visitors). Two patients collapsed with ventricular fibrillation, were defibrillated by lay personnel, quickly regained consciousness, and survived. The other arrests were associated with asystole or electromechanical dissociation; no shocks were inappropriately given, and all four died. We conclude that four of every 1,000 persons at this assembly sought emergency medical care, that 95% of the problems seen were minor with few requiring physician skills, and that the automatic external defibrillator was suited for this setting and could be used by lay responders to provide early definitive treatment.
Golbamaki, Azadi; Benfenati, Emilio; Golbamaki, Nazanin; Manganaro, Alberto; Merdivan, Erinc; Roncaglioni, Alessandra; Gini, Giuseppina
2016-04-02
In this study, new molecular fragments associated with genotoxic and nongenotoxic carcinogens are introduced to estimate the carcinogenic potential of compounds. Two rule-based carcinogenesis models were developed with the aid of SARpy: model R (from rodents' experimental data) and model E (from human carcinogenicity data). Structural alert extraction method of SARpy uses a completely automated and unbiased manner with statistical significance. The carcinogenicity models developed in this study are collections of carcinogenic potential fragments that were extracted from two carcinogenicity databases: the ANTARES carcinogenicity dataset with information from bioassay on rats and the combination of ISSCAN and CGX datasets, which take into accounts human-based assessment. The performance of these two models was evaluated in terms of cross-validation and external validation using a 258 compound case study dataset. Combining R and H predictions and scoring a positive or negative result when both models are concordant on a prediction, increased accuracy to 72% and specificity to 79% on the external test set. The carcinogenic fragments present in the two models were compared and analyzed from the point of view of chemical class. The results of this study show that the developed rule sets will be a useful tool to identify some new structural alerts of carcinogenicity and provide effective information on the molecular structures of carcinogenic chemicals.
Trace element fingerprinting of jewellery rubies by external beam PIXE
NASA Astrophysics Data System (ADS)
Calligaro, T.; Poirot, J.-P.; Querré, G.
1999-04-01
External beam PIXE analysis allows the non-destructive in situ characterisation of gemstones mounted on jewellery pieces. This technique was used for the determination of the geographical origin of 64 rubies set on a high-valued necklace. The trace element content of these gemstones was measured and compared to that of a set of rubies of known sources. Multivariate statistical processing of the results allowed us to infer the provenance of rubies : one comes from Thailand/Cambodia deposit while the remaining are attributed to Burma. This highlights the complementary capabilities of PIXE and conventional gemological observations.
Draw forming of scale shuttle external tank dome gores
NASA Technical Reports Server (NTRS)
Garfield, G.
1974-01-01
The process for manufacturing external tank dome gores is discussed. The test fixture and test procedure are described. The characteristics of the draw forming die are analyzed. The specific subjects included are: (1) forming, (2) trimming, (3) cleaning, and (4) heat treatment.
NASA Technical Reports Server (NTRS)
Reed, Warren D; Clay, William C
1937-01-01
Wind-tunnel and flight tests have been made of a Fairchild 22 airplane equipped with a wing having external-airfoil flaps that also perform the function of ailerons. Lift, drag, and pitching-moment coefficients of the airplane with several flap settings, and the rolling- and yawing-moment coefficients with the flaps deflected as ailerons were measured in the full-scale tunnel with the horizontal tail surfaces and propeller removed. The effect of the flaps on the low speed and on the take-off and landing characteristics, the effectiveness of flaps when used as ailerons, and the forces required to operate them as ailerons were determined in flight. The wind-tunnel tests showed that the flaps increased the maximum lift coefficient of the airplane from 1.51 with the flap in the minimum drag position to 2.12 with the flap in the minimum drag position to 2.12 with the flap deflected 30 degrees. In the flight tests the minimum speed decreased from 46.8 miles per hour with the flaps up to 41.3 miles per hour with the flaps deflected. The required take-off run to attain a height of 50 feet was reduced from 820 to 750 feet and the landing run from a height of 50 feet was reduced from 930 to 480 feet. The flaps for this installation gave lateral control that was not entirely satisfactory. Their rolling action was good but the adverse yaw resulting from their use was greater than is considerable, and the stick forces required to operate them increased too rapidly with speed.
Bellon, Ellen; Ligtenberg, Marjolijn J L; Tejpar, Sabine; Cox, Karen; de Hertogh, Gert; de Stricker, Karin; Edsjö, Anders; Gorgoulis, Vassilis; Höfler, Gerald; Jung, Andreas; Kotsinas, Athanassios; Laurent-Puig, Pierre; López-Ríos, Fernando; Hansen, Tine Plato; Rouleau, Etienne; Vandenberghe, Peter; van Krieken, Johan J M; Dequeker, Elisabeth
2011-01-01
The use of epidermal growth factor receptor-targeting antibodies in metastatic colorectal cancer has been restricted to patients with wild-type KRAS tumors by the European Medicines Agency since 2008, based on data showing a lack of efficacy and potential harm in patients with mutant KRAS tumors. In an effort to ensure optimal, uniform, and reliable community-based KRAS testing throughout Europe, a KRAS external quality assessment (EQA) scheme was set up. The first large assessment round included 59 laboratories from eight different European countries. For each country, one regional scheme organizer prepared and distributed the samples for the participants of their own country. The samples included unstained sections of 10 invasive colorectal carcinomas with known KRAS mutation status. The samples were centrally validated by one of two reference laboratories. The laboratories were allowed to use their own preferred method for histological evaluation, DNA isolation, and mutation analysis. In this study, we analyze the setup of the KRAS scheme. We analyzed the advantages and disadvantages of the regional scheme organization by analyzing the outcome of genotyping results, analysis of tumor percentage, and written reports. We conclude that only 70% of laboratories correctly identified the KRAS mutational status in all samples. Both the false-positive and false-negative results observed negatively affect patient care. Reports of the KRAS test results often lacked essential information. We aim to further expand this program to more laboratories to provide a robust estimate of the quality of KRAS testing in Europe, and provide the basis for remedial measures and harmonization.
Belsky, Jay; Pasco Fearon, R M; Bell, Brian
2007-12-01
Building on prior work, this paper tests, longitudinally and repeatedly, the proposition that attentional control processes mediate the effect of earlier parenting on later externalizing problems. Repeated independent measurements of all three constructs--observed parenting, computer-tested attentional control and adult-reported externalizing problems--were subjected to structural equation modeling using data from the large-scale American study of child care and youth development. Structural equation modeling indicated (a) that greater maternal sensitivity at two different ages (54 months, approximately 6 years) predicted better attentional control on the Continuous Performance Test (CPT) of attention regulation two later ages ( approximately 6/9 years); (2) that better attentional control at three different ages (54 months, approximately 6/9 years) predicted less teacher-reported externalizing problems at three later ages ( approximately 6/8/10 years); and (3) that attentional control partially mediated the effect of parenting on externalizing problems at two different lags (i.e., 54 months--> approximately 6 years--> approximately 8 years; approximately 6 years--> approximately 9 years--> approximately 10 years), though somewhat more strongly for the first. Additionally, (4) some evidence of reciprocal effects of attentional processes on parenting emerged (54 months--> approximately 6 years; approximately 6 years--> approximately 8 years), but not of problem behavior on attention. Because attention control partially mediates the effects of parenting on externalizing problems, intervention efforts could target both parenting and attentional processes.
Externally blown flap noise research
NASA Technical Reports Server (NTRS)
Dorsch, R. G.
1974-01-01
The Lewis Research Center cold-flow model externally blown flap (EBF) noise research test program is summarized. Both engine under-the-wing and over-the-wing EBF wing section configurations were studied. Ten large scale and nineteen small scale EBF models were tested. A limited number of forward airspeed effect and flap noise suppression tests were also run. The key results and conclusions drawn from the flap noise tests are summarized and discussed.
Salehi Sahl Abadi, A; Mazloumi, A; Nasl Saraji, G; Zeraati, H; Hadian, M R; Jafari, A H
2018-03-01
In spite of the increasing degree of automation in industry, manual material handling (MMH) is still performed in many occupational settings. The aim of the current study was to determine the maximum acceptable weight of lift using psychophysical and electromyography indices. This experimental study was conducted among 15 male students recruited from Tehran University of Medical Sciences. Each participant performed 18 different lifting tasks which involved three lifting frequencies, three lifting heights and two box sizes. Each set of experiments was conducted during the 20 min work period using free-style lifting technique and subjective as well as objective assessment methodologies. SPSS version 18 software was used for descriptive and analytical analyses by Friedman, Wilcoxon and Spearman correlation techniques. The results demonstrated that muscle activity increased with increasing frequency, height of lift and box size (P<0.05). Meanwhile, MAWLs obtained in this study are lower than those in Snook table (P<0.05). In this study, the level of muscle activity in percent MVC in relation to the erector spine muscles in L3 and T9 regions as well as left and right abdominal external oblique muscles were at 38.89%, 27.78%, 11.11% and 5.55% in terms of muscle activity is more than 70% MVC, respectively. The results of Wilcoxon test revealed that for both small and large boxes under all conditions, significant differences were detected between the beginning and end of the test values for MPF of erector spine in L3 and T9 regions, and left and right abdominal external oblique muscles (P<0.05). The results of Spearman correlation test showed that there was a significant relation between the MAWL, RMS and MPF of the muscles in all test conditions (P<0.05). Based on the results of this study, it was concluded if muscle activity is more than 70% of MVC, the values of Snook tables should be revisited. Furthermore, the biomechanical perspective should receive special attention in determining the standards for MMH.
Aldekhayel, Salah A; Alselaim, Nahar A; Magzoub, Mohi Eldin; Al-Qattan, Mohammad M; Al-Namlah, Abdullah M; Tamim, Hani; Al-Khayal, Abdullah; Al-Habdan, Sultan I; Zamakhshary, Mohammed F
2012-10-24
Script Concordance Test (SCT) is a new assessment tool that reliably assesses clinical reasoning skills. Previous descriptions of developing SCT-question banks were merely subjective. This study addresses two gaps in the literature: 1) conducting the first phase of a multistep validation process of SCT in Plastic Surgery, and 2) providing an objective methodology to construct a question bank based on SCT. After developing a test blueprint, 52 test items were written. Five validation questions were developed and a validation survey was established online. Seven reviewers were asked to answer this survey. They were recruited from two countries, Saudi Arabia and Canada, to improve the test's external validity. Their ratings were transformed into percentages. Analysis was performed to compare reviewers' ratings by looking at correlations, ranges, means, medians, and overall scores. Scores of reviewers' ratings were between 76% and 95% (mean 86% ± 5). We found poor correlations between reviewers (Pearson's: +0.38 to -0.22). Ratings of individual validation questions ranged between 0 and 4 (on a scale 1-5). Means and medians of these ranges were computed for each test item (mean: 0.8 to 2.4; median: 1 to 3). A subset of test items comprising 27 items was generated based on a set of inclusion and exclusion criteria. This study proposes an objective methodology for validation of SCT-question bank. Analysis of validation survey is done from all angles, i.e., reviewers, validation questions, and test items. Finally, a subset of test items is generated based on a set of criteria.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McMullin, S.R.
The Savannah River Site is currently evaluating some 40 hazardous and radioactive-waste sites for remediation. Among the remedial alternatives considered is closure using a kaolin clay cap. The hydraulic conductivity suggested by the US Environmental Protection Agency is 1.0 {times} 10{sup {minus}7} cm/sec. One instrument to measure this value is the Sealed Double-Ring Infiltrometer{trademark} (SDRI). Six SDRI were recently installed on a kaolin test cap. Test results demonstrated uniform performance of these instruments. However, the test data showed as much as an order of magnitude of variation over time. This variation is attributed to both internal structural heterogeneity and variablemore » external boundary conditions. The internal heterogeneity is caused by construction variability within a specified range of moisture and density. The external influences considered are temperature and barometric pressure. Temperature was discharged as a source of heterogeneity because of a lack of correlation with test data and a negligible impact from the range of variability. However, a direct correlation was found between changes in barometric pressure and hydraulic conductivity. This correlation is most pronounced when pressure changes occur over a short period of time. Additionally, this correlation is related to a single soil layer. When the wetting front passes into a more porous foundation layer, the correlation with pressure changes disappears. Conclusions are that the SDRI performs adequately, with good repeatability of results. The duration of test is critical to assure a statistically valid data set. Data spikes resulting from pressure changes should be identified, and professional judgment used to determine the representative hydraulic conductivity. Further evaluation is recommended to determine the impact of pressure change on the actual hydraulic conductivity.« less
Halabi, Susan; Lin, Chen-Yen; Kelly, W. Kevin; Fizazi, Karim S.; Moul, Judd W.; Kaplan, Ellen B.; Morris, Michael J.; Small, Eric J.
2014-01-01
Purpose Prognostic models for overall survival (OS) for patients with metastatic castration-resistant prostate cancer (mCRPC) are dated and do not reflect significant advances in treatment options available for these patients. This work developed and validated an updated prognostic model to predict OS in patients receiving first-line chemotherapy. Methods Data from a phase III trial of 1,050 patients with mCRPC were used (Cancer and Leukemia Group B CALGB-90401 [Alliance]). The data were randomly split into training and testing sets. A separate phase III trial served as an independent validation set. Adaptive least absolute shrinkage and selection operator selected eight factors prognostic for OS. A predictive score was computed from the regression coefficients and used to classify patients into low- and high-risk groups. The model was assessed for its predictive accuracy using the time-dependent area under the curve (tAUC). Results The model included Eastern Cooperative Oncology Group performance status, disease site, lactate dehydrogenase, opioid analgesic use, albumin, hemoglobin, prostate-specific antigen, and alkaline phosphatase. Median OS values in the high- and low-risk groups, respectively, in the testing set were 17 and 30 months (hazard ratio [HR], 2.2; P < .001); in the validation set they were 14 and 26 months (HR, 2.9; P < .001). The tAUCs were 0.73 (95% CI, 0.70 to 0.73) and 0.76 (95% CI, 0.72 to 0.76) in the testing and validation sets, respectively. Conclusion An updated prognostic model for OS in patients with mCRPC receiving first-line chemotherapy was developed and validated on an external set. This model can be used to predict OS, as well as to better select patients to participate in trials on the basis of their prognosis. PMID:24449231
The influence of applied internal and external rotation on the pivot shift phenomenon.
Kopf, Sebastian; Musahl, Volker; Perka, Carsten; Kauert, Ralf; Hoburg, Arnd; Becker, Roland
2017-04-01
The pivot shift test is performed in different techniques and the rotation of the tibia seems to have a significant impact on the amount of the pivot shift phenomenon. It has been hypothesised that external rotation will increase the phenomenon due to less tension at the iliotibial band in knee extension. Twenty-four patients with unilateral anterior cruciate ligament insufficiency were included prospectively. The pivot shift test was performed bilaterally in internal and external tibial rotation under general anaesthesia. Knee motion was captured using a femoral and a tibial inertial sensor. The difference between positive and negative peak values in Euclidean norm of acceleration was calculated to evaluate the amount of the pivot shift phenomenon. The pivot shift phenomenon was significantly increased in patients with ACL insufficiency when the test was performed in external [mean 5.2 ms - 2 (95% CI 4.3-6.0)] compared to internal tibial rotation [mean 4.4 ms - 2 (95% CI 3.5-5.4)] (p = 0.002). In healthy, contralateral knees did not show any difference between external [mean 4.0 ms - 2 (95% CI 3.3-4.7)] and internal tibial rotation [mean 4.0 ms - 2 (95% CI 3.4-4.6)] (ns). The pivot shift phenomenon was increased with external rotation in ACL-insufficient knees, and therefore, one should perform the pivot shift test, rather, in external rotation to easily evoke the, sometimes difficult to detect, pivot shift phenomenon. I (diagnostic study).
Moorhouse, Kevin; Donnelly, Bruce; Kang, Yun-Seok; Bolte, John H; Herriott, Rodney
2012-10-01
The goal of this study is to evaluate both the internal and external biofidelity of existing rear impact anthropomorphic test devices (BioRID II, RID3D, Hybrid III 50th) in two moderate-speed rear impact sled test conditions (8.5g, 17 km/h; 10.5g, 24 km/h) by quantitatively comparing the ATD responses to biomechanical response targets developed from PMHS testing in a corresponding study. The ATDs and PMHS were tested in an experimental seat system that is capable of simulating the dynamic seat back rotation response of production seats. The experimental seat contains a total of fourteen load cells installed such that external loads from the ATDs and PMHS can be measured to evaluate external biofidelity. The PMHS were instrumented to correspond to the instrumentation contained in the ATDs so that direct comparison between ATDs and PMHS could be made to evaluate internal biofidelity. The NHTSA Biofidelity Ranking system was used to quantitatively evaluate the biofidelity of the ATDs and an additional tool was introduced and utilized which allows for the biofidelity score to be partitioned into components of amplitude, phase, and shape. For internal biofidelity, the BioRID II and RID3D were more biofidelic than the Hybrid III in the 17 km/h test, and the BioRID II was most biofidelic in the 24 km/h test. For external biofidelity, the BioRID II was most biofidelic in the 17 km/h test, while both the BioRID II and the RID3D were more biofidelic than the Hybrid III in the 24 km/h test. Overall, the BioRID II demonstrated the best biofidelity in both the 17 km/h and 24 km/h tests.
Robbins, Shawn M; Caplan, Ryan M; Aponte, Daniel I; St-Onge, Nancy
2017-10-01
External perturbations are utilized to challenge balance and mimic realistic balance threats in patient populations. The reliability of such protocols has not been established. The purpose was to examine test-retest reliability of balance testing with external perturbations. Healthy adults (n=34; mean age 23 years) underwent balance testing over two visits. Participants completed ten balance conditions in which the following parameters were combined: perturbation or non-perturbation, single or double leg, and eyes open or closed. Three trials were collected for each condition. Data were collected on a force plate and external perturbations were applied by translating the plate. Force plate center of pressure (CoP) data were summarized using 13 different CoP measures. Test-retest reliability was examined using intraclass correlation coefficients (ICC) and Bland-Altman plots. CoP measures of total speed and excursion in both anterior-posterior and medial-lateral directions generally had acceptable ICC values for perturbation conditions (ICC=0.46 to 0.87); however, many other CoP measures (e.g. range, area of ellipse) had unacceptable test-retest reliability (ICC<0.70). Improved CoP measures were present on the second visit indicating a potential learning effect. Non-perturbation conditions generally produced more reliable CoP measures than perturbation conditions during double leg standing, but not single leg standing. Therefore, changes to balance testing protocols that include external perturbations should be made to improve test-retest reliability and diminish learning including more extensive participant training and increasing the number of trials. CoP measures that consider all data points (e.g. total speed) are more reliable than those that only consider a few data points. Copyright © 2017 Elsevier B.V. All rights reserved.
Analysis of model development strategies: predicting ventral hernia recurrence.
Holihan, Julie L; Li, Linda T; Askenasy, Erik P; Greenberg, Jacob A; Keith, Jerrod N; Martindale, Robert G; Roth, J Scott; Liang, Mike K
2016-11-01
There have been many attempts to identify variables associated with ventral hernia recurrence; however, it is unclear which statistical modeling approach results in models with greatest internal and external validity. We aim to assess the predictive accuracy of models developed using five common variable selection strategies to determine variables associated with hernia recurrence. Two multicenter ventral hernia databases were used. Database 1 was randomly split into "development" and "internal validation" cohorts. Database 2 was designated "external validation". The dependent variable for model development was hernia recurrence. Five variable selection strategies were used: (1) "clinical"-variables considered clinically relevant, (2) "selective stepwise"-all variables with a P value <0.20 were assessed in a step-backward model, (3) "liberal stepwise"-all variables were included and step-backward regression was performed, (4) "restrictive internal resampling," and (5) "liberal internal resampling." Variables were included with P < 0.05 for the Restrictive model and P < 0.10 for the Liberal model. A time-to-event analysis using Cox regression was performed using these strategies. The predictive accuracy of the developed models was tested on the internal and external validation cohorts using Harrell's C-statistic where C > 0.70 was considered "reasonable". The recurrence rate was 32.9% (n = 173/526; median/range follow-up, 20/1-58 mo) for the development cohort, 36.0% (n = 95/264, median/range follow-up 20/1-61 mo) for the internal validation cohort, and 12.7% (n = 155/1224, median/range follow-up 9/1-50 mo) for the external validation cohort. Internal validation demonstrated reasonable predictive accuracy (C-statistics = 0.772, 0.760, 0.767, 0.757, 0.763), while on external validation, predictive accuracy dipped precipitously (C-statistic = 0.561, 0.557, 0.562, 0.553, 0.560). Predictive accuracy was equally adequate on internal validation among models; however, on external validation, all five models failed to demonstrate utility. Future studies should report multiple variable selection techniques and demonstrate predictive accuracy on external data sets for model validation. Copyright © 2016 Elsevier Inc. All rights reserved.
Wang, Danny T; Chen, Wendy Y
2014-03-15
The question of how foreign direct investment (FDI) affects a host country's natural environment has generated much debate but little consensus. Building on an institution-based theory, this article examines how the institutional development of a host setting affects the degree of FDI-related environmental externalities in China (specifically, industrial sulfur dioxide emissions). With a panel data set of 287 Chinese cities, over the period 2002-2009, this study reveals that FDI in general induces negative environmental externalities. Investments from OECD countries increase sulfur dioxide emissions, whereas FDI from Hong Kong, Macau, and Taiwan shows no significant effect. Institutional development reduces the impacts of FDI across the board. By focusing on the moderating role of institutions, this study sheds new light on the long-debated relationships among FDI, institutions, and the environments of the host countries. Copyright © 2014 Elsevier Ltd. All rights reserved.
Fauth, Elizabeth B; Jackson, Mark A; Walberg, Donna K; Lee, Nancy E; Easom, Leisa R; Alston, Gayle; Ramos, Angel; Felten, Kristen; LaRue, Asenath; Mittelman, Mary
2017-06-01
The Administration on Aging funded six New York University Caregiver Intervention (NYUCI) demonstration projects, a counseling/support intervention targeting dementia caregivers and families. Three sites (Georgia, Utah, Wisconsin) pooled data to inform external validity in nonresearch settings. This study (a) assesses collective changes over time, and (b) compares outcomes across sites on caregiver burden, depressive symptoms, satisfaction with social support, family conflict, and quality of life. Data included baseline/preintervention ( N = 294) and follow-up visits (approximately 4, 8, 12 months). Linear mixed models showed that social support satisfaction increased ( p < .05) and family conflict decreased ( p < .05; Cohen's d = 0.49 and 0.35, respectively). Marginally significant findings emerged for quality of life increases ( p = .05) and burden decreases ( p < .10). Depressive symptoms remained stable. Slopes did not differ much by site. NYUCI demonstrated external validity in nonresearch settings across diverse caregiver samples.
Campana, Lorenzo; Breitbeck, Robert; Bauer-Kreuz, Regula; Buck, Ursula
2016-05-01
This study evaluated the feasibility of documenting patterned injury using three dimensions and true colour photography without complex 3D surface documentation methods. This method is based on a generated 3D surface model using radiologic slice images (CT) while the colour information is derived from photographs taken with commercially available cameras. The external patterned injuries were documented in 16 cases using digital photography as well as highly precise photogrammetry-supported 3D structured light scanning. The internal findings of these deceased were recorded using CT and MRI. For registration of the internal with the external data, two different types of radiographic markers were used and compared. The 3D surface model generated from CT slice images was linked with the photographs, and thereby digital true-colour 3D models of the patterned injuries could be created (Image projection onto CT/IprojeCT). In addition, these external models were merged with the models of the somatic interior. We demonstrated that 3D documentation and visualization of external injury findings by integration of digital photography in CT/MRI data sets is suitable for the 3D documentation of individual patterned injuries to a body. Nevertheless, this documentation method is not a substitution for photogrammetry and surface scanning, especially when the entire bodily surface is to be recorded in three dimensions including all external findings, and when precise data is required for comparing highly detailed injury features with the injury-inflicting tool.
Vision-based guidance for an automated roving vehicle
NASA Technical Reports Server (NTRS)
Griffin, M. D.; Cunningham, R. T.; Eskenazi, R.
1978-01-01
A controller designed to guide an automated vehicle to a specified target without external intervention is described. The intended application is to the requirements of planetary exploration, where substantial autonomy is required because of the prohibitive time lags associated with closed-loop ground control. The guidance algorithm consists of a set of piecewise-linear control laws for velocity and steering commands, and is executable in real time with fixed-point arithmetic. The use of a previously-reported object tracking algorithm for the vision system to provide position feedback data is described. Test results of the control system on a breadboard rover at the Jet Propulsion Laboratory are included.
14 CFR 27.865 - External loads.
Code of Federal Regulations, 2012 CFR
2012-01-01
... Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS... must be shown by analysis, test, or both, that the rotorcraft external load attaching means for rotorcraft-load combinations to be used for nonhuman external cargo applications can withstand a limit static...
14 CFR 27.865 - External loads.
Code of Federal Regulations, 2014 CFR
2014-01-01
... Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS... must be shown by analysis, test, or both, that the rotorcraft external load attaching means for rotorcraft-load combinations to be used for nonhuman external cargo applications can withstand a limit static...
14 CFR 27.865 - External loads.
Code of Federal Regulations, 2013 CFR
2013-01-01
... Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS... must be shown by analysis, test, or both, that the rotorcraft external load attaching means for rotorcraft-load combinations to be used for nonhuman external cargo applications can withstand a limit static...
14 CFR 27.865 - External loads.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS... must be shown by analysis, test, or both, that the rotorcraft external load attaching means for rotorcraft-load combinations to be used for nonhuman external cargo applications can withstand a limit static...
14 CFR 27.865 - External loads.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS... must be shown by analysis, test, or both, that the rotorcraft external load attaching means for rotorcraft-load combinations to be used for nonhuman external cargo applications can withstand a limit static...
Habets, Bas; Staal, J Bart; Tijssen, Marsha; van Cingel, Robert
2018-01-10
To determine the intrarater reliability of the Humac NORM isokinetic dynamometer for concentric and eccentric strength tests of knee and shoulder muscles. 54 participants (50% female, average age 20.9 ± 3.1 years) performed concentric and eccentric strength measures of the knee extensors and flexors, and the shoulder internal and external rotators on two different Humac NORM isokinetic dynamometers, which were situated at two different centers. The knee extensors and flexors were tested concentrically at 60° and 180°/s, and eccentrically at 60° s. Concentric strength of the shoulder internal and external rotators, and eccentric strength of the external rotators were measured at 60° and 120°/s. We calculated intraclass correlation coefficients (ICCs), standard error of measurement, standard error of measurement expressed as a %, and the smallest detectable change to determine reliability and measurement error. ICCs for the knee tests ranged from 0.74 to 0.89, whereas ICC values for the shoulder tests ranged from 0.72 to 0.94. Measurement error was highest for the concentric test of the knee extensors and lowest for the concentric test of shoulder external rotators.
Full-Scale Crash Test of a MD-500 Helicopter with Deployable Energy Absorbers
NASA Technical Reports Server (NTRS)
Kellas, Sotiris; Jackson, Karen E.; Littell, Justin D.
2010-01-01
A new externally deployable energy absorbing system was demonstrated during a full-scale crash test of an MD-500 helicopter. The deployable system is a honeycomb structure and utilizes composite materials in its construction. A set of two Deployable Energy Absorbers (DEAs) were fitted on the MD-500 helicopter for the full-scale crash demonstration. Four anthropomorphic dummy occupants were also used to assess human survivability. A demonstration test was performed at NASA Langley's Landing and Impact Research Facility (LandIR). The test involved impacting the helicopter on a concrete surface with combined forward and vertical velocity components of 40-ft/s and 26-ft/s, respectively. The objectives of the test were to evaluate the performance of the DEA concept under realistic crash conditions and to generate test data for validation of dynamic finite element simulations. Descriptions of this test as well as other component and full-scale tests leading to the helicopter test are discussed. Acceleration data from the anthropomorphic dummies showed that dynamic loads were successfully attenuated to within non-injurious levels. Moreover, the airframe itself survived the relatively severe impact and was retested to provide baseline data for comparison for cases with and without DEAs.
Osterberg, T; Norinder, U
2001-01-01
A method of modelling and predicting biopharmaceutical properties using simple theoretically computed molecular descriptors and multivariate statistics has been investigated for several data sets related to solubility, IAM chromatography, permeability across Caco-2 cell monolayers, human intestinal perfusion, brain-blood partitioning, and P-glycoprotein ATPase activity. The molecular descriptors (e.g. molar refractivity, molar volume, index of refraction, surface tension and density) and logP were computed with ACD/ChemSketch and ACD/logP, respectively. Good statistical models were derived that permit simple computational prediction of biopharmaceutical properties. All final models derived had R(2) values ranging from 0.73 to 0.95 and Q(2) values ranging from 0.69 to 0.86. The RMSEP values for the external test sets ranged from 0.24 to 0.85 (log scale).
3D-QSAR analysis of MCD inhibitors by CoMFA and CoMSIA.
Pourbasheer, Eslam; Aalizadeh, Reza; Ebadi, Amin; Ganjali, Mohammad Reza
2015-01-01
Three-dimensional quantitative structure-activity relationship was developed for the series of compounds as malonyl-CoA decarboxylase antagonists (MCD) using the CoMFA and CoMSIA methods. The statistical parameters for CoMFA (q(2)=0.558, r(2)=0.841) and CoMSIA (q(2)= 0.615, r(2) = 0.870) models were derived based on 38 compounds as training set in the basis of the selected alignment. The external predictive abilities of the built models were evaluated by using the test set of nine compounds. From obtained results, the CoMSIA method was found to have highly predictive capability in comparison with CoMFA method. Based on the given results by CoMSIA and CoMFA contour maps, some features that can enhance the activity of compounds as MCD antagonists were introduced and used to design new compounds with better inhibition activity.
Mermelstein, Robin J.; Revenson, Tracey A.
2013-01-01
Basic social psychological theories have much to contribute to our understanding of health problems and health-related behaviors and may provide potential avenues for intervention development. However, for these theories to have broader reach and applicability to the field of health psychology, more work needs to be done in integrating contexts into these theories and addressing more specifically their application across settings, behaviors, and populations. We argue that integration of these theories into a broader multi-disciplinary and multi-level ecological framework is needed to enhance their translation into real-world applications. To enhance this translation, we make several recommendations, including breaking down silos between disciplinary perspectives and enhancing bidirectional communication and translation; analyzing boundary conditions of theories; expanding research approaches to move outside the laboratory and maintain a focus on external validity; and conducting efficacy testing of theories with meaningful, relevant endpoints. PMID:23646843
Guidelines on Good Clinical Laboratory Practice
Ezzelle, J.; Rodriguez-Chavez, I. R.; Darden, J. M.; Stirewalt, M.; Kunwar, N.; Hitchcock, R.; Walter, T.; D’Souza, M. P.
2008-01-01
A set of Good Clinical Laboratory Practice (GCLP) standards that embraces both the research and clinical aspects of GLP were developed utilizing a variety of collected regulatory and guidance material. We describe eleven core elements that constitute the GCLP standards with the objective of filling a gap for laboratory guidance, based on IND sponsor requirements, for conducting laboratory testing using specimens from human clinical trials. These GCLP standards provide guidance on implementing GLP requirements that are critical for laboratory operations, such as performance of protocol-mandated safety assays, peripheral blood mononuclear cell processing and immunological or endpoint assays from biological interventions on IND-registered clinical trials. The expectation is that compliance with the GCLP standards, monitored annually by external audits, will allow research and development laboratories to maintain data integrity and to provide immunogenicity, safety, and product efficacy data that is repeatable, reliable, auditable and that can be easily reconstructed in a research setting. PMID:18037599
Mermelstein, Robin J; Revenson, Tracey A
2013-05-01
Basic social psychological theories have much to contribute to our understanding of health problems and health-related behaviors and may provide potential avenues for intervention development. However, for these theories to have broader reach and applicability to the field of health psychology, more work needs to be done in integrating contexts into these theories and addressing more specifically their application across settings, behaviors, and populations. We argue that integration of these theories into a broader multidisciplinary and multilevel ecological framework is needed to enhance their translation into real-world applications. To enhance this translation, we make several recommendations, including breaking down silos between disciplinary perspectives and enhancing bidirectional communication and translation; analyzing boundary conditions of theories; expanding research approaches to move outside the laboratory and maintain a focus on external validity; and conducting efficacy testing of theories with meaningful, relevant endpoints. PsycINFO Database Record (c) 2013 APA, all rights reserved.
Building a Practically Useful Theory of Goal Setting and Task Motivation.
ERIC Educational Resources Information Center
Locke, Edwin A.; Latham, Gary P.
2002-01-01
Summarizes 35 years of empirical research on goal-setting theory, describing core findings of the theory, mechanisms by which goals operate, moderators of goal effects, the relation of goals and satisfaction, and the role of goals as mediators of incentives. Explains the external validity and practical significance of goal setting theory,…
Datu, Jesus Alfonso D; Jose Mateo, Nino
2017-03-01
The objective of the study was to assess the moderating role of locus-of-hope on the relations between everyday discrimination and well-being outcomes in a collectivist setting. There were 444 Filipino undergraduate students who participated in the research. Findings showed that discrimination was negatively linked to subjective well-being and flourishing while loci-of-hope (internal, external-spiritual, external-family, and external-peers) were positively associated with well-being indices. Further, external-peer locus-of-hope moderated the relations between everyday discrimination and well-being outcomes such that for those who had higher external-peer locus-of-hope, everyday discrimination may still be linked to greater well-being. The theoretical and practical implications are elucidated.
Development of a new in-air micro-PIXE set-up with in-vacuum charge measurements in Atomki
NASA Astrophysics Data System (ADS)
Török, Zs.; Huszánk, R.; Csedreki, L.; Dani, J.; Szoboszlai, Z.; Kertész, Zs.
2015-11-01
A new external microbeam set-up has recently been installed as the extension of the existing microprobe system at the Laboratory of Ion Beam Applications of Atomki, Debrecen, Hungary. The external beam set-up, based on the system of Oxford Microbeams (OM), is equipped with two X-ray detectors for PIXE analysis, a digital microscope, two alignment lasers and a precision XYZ stage for easy and reproducible positioning of the sample. Exit windows with different thicknesses and of different materials can be used according to the actual demands, currently silicon-nitride (Si3N4) film with 200 nm thickness is employed in our laboratory. The first application was demonstrated in the field of archaeometry, on Bronze Age hoards from Hungary.
NASA Astrophysics Data System (ADS)
Tao, Qiuxiang; Gao, Tengfei; Liu, Guolin; Wang, Zhiwei
2017-04-01
The external digital elevation model (DEM) error is one of the main factors that affect the accuracy of mine subsidence monitored by two-pass differential interferometric synthetic aperture radar (DInSAR), which has been widely used in monitoring mining-induced subsidence. The theoretical relationship between external DEM error and monitored deformation error is derived based on the principles of interferometric synthetic aperture radar (DInSAR) and two-pass DInSAR. Taking the Dongtan and Yangcun mine areas of Jining as test areas, the difference and accuracy of 1:50000, ASTER GDEM V2, and SRTM DEMs are compared and analyzed. Two interferometric pairs of Advanced Land Observing Satellite Phased Array L-band SAR covering the test areas are processed using two-pass DInSAR with three external DEMs to compare and analyze the effect of three external DEMs on monitored mine subsidence in high- and low-coherence subsidence regions. Moreover, the reliability and accuracy of the three DInSAR-monitored results are compared and verified with leveling-measured subsidence values. Results show that the effect of external DEM on mine subsidence monitored by two-pass DInSAR is not only related to radar look angle, perpendicular baseline, slant range, and external DEM error, but also to the ground resolution of DEM, the magnitude of subsidence, and the coherence of test areas.
Comparison of two vertical condensation obturation techniques: Touch 'n Heat modified and System B.
Silver, G K; Love, R M; Purton, D G
1999-08-01
The aims of this study were firstly to compare the area of canal occupied by gutta-percha, sealer or voids using the System B heating device with that obtained by a modified vertical condensation technique using the Touch 'n Heat: and secondly to compare the temperature changes at the root canal wall and external root surface during obturation with the above techniques. Forty-five resin blocks, each with a standardized, simulated, prepared main root canal and five lateral canals, were assigned to three equal experimental groups. The canals were obturated using either the System B technique at two different temperature settings, or vertical condensation with a Touch 'n Heat instrument as the heat source. A heat transfer model was used to simultaneously record internal and external root surface temperature elevations during obturation by the three techniques. Data were analysed using unpaired Student's t-test and Mann-Whitney U-test. Both obturation techniques produced root fillings consisting of over 90% gutta-percha at most levels, although the percentages of sealer and voids 2-3 mm from the working length following System B obturation were higher than those found following modified vertical condensation. Modified vertical condensation resulted in more gutta-percha in lateral canals. Obturation was accomplished more quickly using the System B, and temperature elevations produced during obturation with the System B were significantly less (P < 0.001) than with vertical condensation. An elevation of external root surface temperature by more than 10 degrees C occurred during vertical condensation. The results suggest that the System B may produce an acceptable obturation and that the use of a Touch 'n Heat source during vertical condensation may result in damage to the periodontium.
NASA Technical Reports Server (NTRS)
Janardan, B. A.; Hoff, G. E.; Barter, J. W.; Brausch, J. F.; Gliebe, P. R.; Coffin, R. S.; Martens, S.; Delaney, B. R.; Dalton, W. N.; Mengle, V. G.
2000-01-01
This presentation discusses: Project Objectives, Approach and Goal; Baseline Nozzles and Test Cycle Definition; Repeatability and Baseline Nozzle Results; Noise Reduction Concepts; Noise Reduction Tests Configurations of BPR=5 Internal Plug Nozzle adn Acoustic Results; Noise Reduction Test Configurations of BPR=5 External Plug Nozzle and Acoustic Results; and Noise Reduction Tests Configurations of BPR=8 External Plug Nozzle and Acoustic Results.
Adult Learners, Tutors and the Challenge of Assessment at a Distance
ERIC Educational Resources Information Center
Stephens, Simon; O'Donnell, David; McCusker, Paul
2007-01-01
This article explores the experiences of adult learners and tutors on a particular externally assessed distance-learning degree programme. On this programme, assignments are set, reviewed and graded independently of the on-site tutor by the external awarding body. An analysis of eight interviews with four tutors and four graduates from one such…
Analysis of Leadership Dynamics in Educational Settings during Times of External and Internal Change
ERIC Educational Resources Information Center
Jäppinen, Aini-Kristiina
2017-01-01
Background: The article concerns the tensions that can arise during demanding external, and consequential internal changes and considers how educational leadership is able to respond to them. Leadership is here understood as a collaborative endeavour, producing shared sense-making in situations of tension. Purpose: The main research question was:…
Positive Psychology and Externalizing Students in a Sea of Negativity
ERIC Educational Resources Information Center
Jenson, William R.; Olympia, Daniel; Farley, Megan; Clark, Elaine
2004-01-01
Students with externalizing disorders make up from three to five percent of the population in public school classrooms and are some of the most difficult students to manage in an educational setting. Behavioral excesses and deficits exhibited by these students are a major factor in poor retention rates for new teachers while the students…
External tank aerothermal design criteria verification, volume 2
NASA Technical Reports Server (NTRS)
Crain, William K.; Frost, Cynthia; Warmbrod, John
1990-01-01
The objective of the study was to produce an independent set of ascent environments which would serve as a check on the Rockwell International (RI) IVBC-3 environments and provide an independent reevaluation of the thermal design criteria for the External Tank (ET). Given here are the plotted timewise environments comparing REMTECH results to the RI IVBC results.
Teaching with External Representations: The Case of a Common Energy-Level Diagram in Chemistry
ERIC Educational Resources Information Center
Orgill, MaryKay; Crippen, Kent
2010-01-01
Diagrams and figures play a central role in science and science education. Research has indicated that, when presented and used properly in a classroom setting, these external representations can contribute to students' understanding of scientific concepts; however, it is apparent that students do not always use, understand, interpret, or value…
Gwenlyn Busby; Gregory S. Amacher; Robert G. Haight
2013-01-01
In this article, we consider wildfire risk management decisions using a dynamic stochastic model of homeowner interaction in a setting where spatial externalities arise. Our central objective is to apply observations from the social science literature about homeowner preferences to this economic externality problem and determine how assumptions about insurance,...
ERIC Educational Resources Information Center
Forster, Martin; Sundell, Knut; Morris, Richard J.; Karlberg, Martin; Melin, Lennart
2012-01-01
This study reports the results from a Swedish randomized controlled trial of a standardized behavior management intervention. The intervention targeted students with externalizing behavior in a regular education setting. First- and second-grade students (N = 100) from 38 schools were randomly assigned to either the intervention or an active…
Prospective memory in an air traffic control simulation: External aids that signal when to act
Loft, Shayne; Smith, Rebekah E.; Bhaskara, Adella
2011-01-01
At work and in our personal life we often need to remember to perform intended actions at some point in the future, referred to as Prospective Memory. Individuals sometimes forget to perform intentions in safety-critical work contexts. Holding intentions can also interfere with ongoing tasks. We applied theories and methods from the experimental literature to test the effectiveness of external aids in reducing prospective memory error and costs to ongoing tasks in an air traffic control simulation. Participants were trained to accept and hand-off aircraft, and to detect aircraft conflicts. For the prospective memory task participants were required to substitute alternative actions for routine actions when accepting target aircraft. Across two experiments, external display aids were provided that presented the details of target aircraft and associated intended actions. We predicted that aids would only be effective if they provided information that was diagnostic of target occurrence and in this study we examined the utility of aids that directly cued participants when to allocate attention to the prospective memory task. When aids were set to flash when the prospective memory target aircraft needed to be accepted, prospective memory error and costs to ongoing tasks of aircraft acceptance and conflict detection were reduced. In contrast, aids that did not alert participants specifically when the target aircraft were present provided no advantage compared to when no aids we used. These findings have practical implications for the potential relative utility of automated external aids for occupations where individuals monitor multi-item dynamic displays. PMID:21443381
Prospective memory in an air traffic control simulation: external aids that signal when to act.
Loft, Shayne; Smith, Rebekah E; Bhaskara, Adella
2011-03-01
At work and in our personal life we often need to remember to perform intended actions at some point in the future, referred to as Prospective Memory. Individuals sometimes forget to perform intentions in safety-critical work contexts. Holding intentions can also interfere with ongoing tasks. We applied theories and methods from the experimental literature to test the effectiveness of external aids in reducing prospective memory error and costs to ongoing tasks in an air traffic control simulation. Participants were trained to accept and hand-off aircraft and to detect aircraft conflicts. For the prospective memory task, participants were required to substitute alternative actions for routine actions when accepting target aircraft. Across two experiments, external display aids were provided that presented the details of target aircraft and associated intended actions. We predicted that aids would only be effective if they provided information that was diagnostic of target occurrence, and in this study, we examined the utility of aids that directly cued participants when to allocate attention to the prospective memory task. When aids were set to flash when the prospective memory target aircraft needed to be accepted, prospective memory error and costs to ongoing tasks of aircraft acceptance and conflict detection were reduced. In contrast, aids that did not alert participants specifically when the target aircraft were present provided no advantage compared to when no aids were used. These findings have practical implications for the potential relative utility of automated external aids for occupations where individuals monitor multi-item dynamic displays.
Ren, Biye
2003-01-01
Structure-boiling point relationships are studied for a series of oxo organic compounds by means of multiple linear regression (MLR) analysis. Excellent MLR models based on the recently introduced Xu index and the atom-type-based AI indices are obtained for the two subsets containing respectively 77 ethers and 107 carbonyl compounds and a combined set of 184 oxo compounds. The best models are tested using the leave-one-out cross-validation and an external test set, respectively. The MLR model produces a correlation coefficient of r = 0.9977 and a standard error of s = 3.99 degrees C for the training set of 184 compounds, and r(cv) = 0.9974 and s(cv) = 4.16 degrees C for the cross-validation set, and r(pred) = 0.9949 and s(pred) = 4.38 degrees C for the prediction set of 21 compounds. For the two subsets containing respectively 77 ethers and 107 carbonyl compounds, the quality of the models is further improved. The standard errors are reduced to 3.30 and 3.02 degrees C, respectively. Furthermore, the results obtained from this study indicate that the boiling points of the studied oxo compound dominantly depend on molecular size and also depend on individual atom types, especially oxygen heteroatoms in molecules due to strong polar interactions between molecules. These excellent structure-boiling point models not only provide profound insights into the role of structural features in a molecule but also illustrate the usefulness of these indices in QSPR/QSAR modeling of complex compounds.
Maples, Jessica L; Carter, Nathan T; Few, Lauren R; Crego, Cristina; Gore, Whitney L; Samuel, Douglas B; Williamson, Rachel L; Lynam, Donald R; Widiger, Thomas A; Markon, Kristian E; Krueger, Robert F; Miller, Joshua D
2015-12-01
The fifth edition of the Diagnostic and Statistical Manual of Mental Disorders (DSM-5) includes an alternative model of personality disorders (PDs) in Section III, consisting in part of a pathological personality trait model. To date, the 220-item Personality Inventory for DSM-5 (PID-5; Krueger, Derringer, Markon, Watson, & Skodol, 2012) is the only extant self-report instrument explicitly developed to measure this pathological trait model. The present study used item response theory-based analyses in a large sample (n = 1,417) to investigate whether a reduced set of 100 items could be identified from the PID-5 that could measure the 25 traits and 5 domains. This reduced set of PID-5 items was then tested in a community sample of adults currently receiving psychological treatment (n = 109). Across a wide range of criterion variables including NEO PI-R domains and facets, DSM-5 Section II PD scores, and externalizing and internalizing outcomes, the correlational profiles of the original and reduced versions of the PID-5 were nearly identical (rICC = .995). These results provide strong support for the hypothesis that an abbreviated set of PID-5 items can be used to reliably, validly, and efficiently assess these personality disorder traits. The ability to assess the DSM-5 Section III traits using only 100 items has important implications in that it suggests these traits could still be measured in settings in which assessment-related resources (e.g., time, compensation) are limited. (c) 2015 APA, all rights reserved).
Rahman, M Shafiqur; Ambler, Gareth; Choodari-Oskooei, Babak; Omar, Rumana Z
2017-04-18
When developing a prediction model for survival data it is essential to validate its performance in external validation settings using appropriate performance measures. Although a number of such measures have been proposed, there is only limited guidance regarding their use in the context of model validation. This paper reviewed and evaluated a wide range of performance measures to provide some guidelines for their use in practice. An extensive simulation study based on two clinical datasets was conducted to investigate the performance of the measures in external validation settings. Measures were selected from categories that assess the overall performance, discrimination and calibration of a survival prediction model. Some of these have been modified to allow their use with validation data, and a case study is provided to describe how these measures can be estimated in practice. The measures were evaluated with respect to their robustness to censoring and ease of interpretation. All measures are implemented, or are straightforward to implement, in statistical software. Most of the performance measures were reasonably robust to moderate levels of censoring. One exception was Harrell's concordance measure which tended to increase as censoring increased. We recommend that Uno's concordance measure is used to quantify concordance when there are moderate levels of censoring. Alternatively, Gönen and Heller's measure could be considered, especially if censoring is very high, but we suggest that the prediction model is re-calibrated first. We also recommend that Royston's D is routinely reported to assess discrimination since it has an appealing interpretation. The calibration slope is useful for both internal and external validation settings and recommended to report routinely. Our recommendation would be to use any of the predictive accuracy measures and provide the corresponding predictive accuracy curves. In addition, we recommend to investigate the characteristics of the validation data such as the level of censoring and the distribution of the prognostic index derived in the validation setting before choosing the performance measures.
NASA Technical Reports Server (NTRS)
Montoya, L. C.; Lux, D. P.
1975-01-01
Wing pressure distributions obtained in flight with flush orifice and external tubing orifice installations for Mach numbers from 0.50 to 0.97 are compared. The procedure used to install the external tubing orifice is discussed. The results indicate that external tubing orifice installations can give useful results.
14 CFR 29.865 - External loads.
Code of Federal Regulations, 2014 CFR
2014-01-01
... Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS...) It must be shown by analysis, test, or both, that the rotorcraft external load attaching means for rotorcraft-load combinations to be used for nonhuman external cargo applications can withstand a limit static...
14 CFR 29.865 - External loads.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS...) It must be shown by analysis, test, or both, that the rotorcraft external load attaching means for rotorcraft-load combinations to be used for nonhuman external cargo applications can withstand a limit static...
14 CFR 29.865 - External loads.
Code of Federal Regulations, 2012 CFR
2012-01-01
... Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS...) It must be shown by analysis, test, or both, that the rotorcraft external load attaching means for rotorcraft-load combinations to be used for nonhuman external cargo applications can withstand a limit static...
14 CFR 29.865 - External loads.
Code of Federal Regulations, 2013 CFR
2013-01-01
... Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS...) It must be shown by analysis, test, or both, that the rotorcraft external load attaching means for rotorcraft-load combinations to be used for nonhuman external cargo applications can withstand a limit static...
14 CFR 29.865 - External loads.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS...) It must be shown by analysis, test, or both, that the rotorcraft external load attaching means for rotorcraft-load combinations to be used for nonhuman external cargo applications can withstand a limit static...
NASA Technical Reports Server (NTRS)
Walstad, D. G.
1976-01-01
Ascent heating data were obtained at conditions simulating real gas effects at hypersonic Mach numbers. The configurations tested were Orbiter alone, external tank alone, and mated Orbiter and external tank. A boundary layer trip investigation was conducted for all configurations. The test was conducted at Mach 6 and Reynolds number of one half million per foot for 0 deg and -5 deg angle-of-attack. Selected thermocouples were chosen from the Orbiter and external tank to be used for obtaining heat transfer measurements. A maximum of 42 thermocouples could be measured by the facility data acquisition at one time and no attempt was made to record the excess thermocouples located on the model. Photographs of the test configurations are shown.
Li, Jiazhong; Gramatica, Paola
2010-11-01
Quantitative structure-activity relationship (QSAR) methodology aims to explore the relationship between molecular structures and experimental endpoints, producing a model for the prediction of new data; the predictive performance of the model must be checked by external validation. Clearly, the qualities of chemical structure information and experimental endpoints, as well as the statistical parameters used to verify the external predictivity have a strong influence on QSAR model reliability. Here, we emphasize the importance of these three aspects by analyzing our models on estrogen receptor binders (Endocrine disruptor knowledge base (EDKB) database). Endocrine disrupting chemicals, which mimic or antagonize the endogenous hormones such as estrogens, are a hot topic in environmental and toxicological sciences. QSAR shows great values in predicting the estrogenic activity and exploring the interactions between the estrogen receptor and ligands. We have verified our previously published model for additional external validation on new EDKB chemicals. Having found some errors in the used 3D molecular conformations, we redevelop a new model using the same data set with corrected structures, the same method (ordinary least-square regression, OLS) and DRAGON descriptors. The new model, based on some different descriptors, is more predictive on external prediction sets. Three different formulas to calculate correlation coefficient for the external prediction set (Q2 EXT) were compared, and the results indicated that the new proposal of Consonni et al. had more reasonable results, consistent with the conclusions from regression line, Williams plot and root mean square error (RMSE) values. Finally, the importance of reliable endpoints values has been highlighted by comparing the classification assignments of EDKB with those of another estrogen receptor binders database (METI): we found that 16.1% assignments of the common compounds were opposite (20 among 124 common compounds). In order to verify the real assignments for these inconsistent compounds, we predicted these samples, as a blind external set, by our regression models and compared the results with the two databases. The results indicated that most of the predictions were consistent with METI. Furthermore, we built a kNN classification model using the 104 consistent compounds to predict those inconsistent ones, and most of the predictions were also in agreement with METI database.
Sivan, Sree Kanth; Manga, Vijjulatha
2012-02-01
Multiple receptors conformation docking (MRCD) and clustering of dock poses allows seamless incorporation of receptor binding conformation of the molecules on wide range of ligands with varied structural scaffold. The accuracy of the approach was tested on a set of 120 cyclic urea molecules having HIV-1 protease inhibitory activity using 12 high resolution X-ray crystal structures and one NMR resolved conformation of HIV-1 protease extracted from protein data bank. A cross validation was performed on 25 non-cyclic urea HIV-1 protease inhibitor having varied structures. The comparative molecular field analysis (CoMFA) and comparative molecular similarity indices analysis (CoMSIA) models were generated using 60 molecules in the training set by applying leave one out cross validation method, r (loo) (2) values of 0.598 and 0.674 for CoMFA and CoMSIA respectively and non-cross validated regression coefficient r(2) values of 0.983 and 0.985 were obtained for CoMFA and CoMSIA respectively. The predictive ability of these models was determined using a test set of 60 cyclic urea molecules that gave predictive correlation (r (pred) (2) ) of 0.684 and 0.64 respectively for CoMFA and CoMSIA indicating good internal predictive ability. Based on this information 25 non-cyclic urea molecules were taken as a test set to check the external predictive ability of these models. This gave remarkable out come with r (pred) (2) of 0.61 and 0.53 for CoMFA and CoMSIA respectively. The results invariably show that this method is useful for performing 3D QSAR analysis on molecules having different structural motifs.
Setting Up a Patient Care Call Center After Potential HCV Exposure.
Friedman, Candace; Bucholz, Brigette; Anderson, Susan G; Dwyer, Shon A; Aguirre, Josephine
2016-09-01
Notify patients of a potential exposure to hepatitis C virus, coordinate testing, and provide follow-up counseling. A team was convened to identify various needs in developing a patient care call center. The areas addressed included the following: location, hours, and duration; telephone accessibility; tracking calls and test results; billing; staffing; notification; and potential issues requiring additional evaluation. Disclosure letters were sent to 1275 patients; 57 letters were not deliverable. There were 245 calls to the helpline from October 25 through November 15. Lessons learned centered on hours of availability, staffing, use of an automated phone system and email communication, tracking results, and billing issues. A successful patient notification and follow-up effort requires a multidisciplinary team, internal and external communication, collection of data over an extended period, and coordination of patient information.
GNSS Signal Authentication Via Power and Distortion Monitoring
NASA Astrophysics Data System (ADS)
Wesson, Kyle D.; Gross, Jason N.; Humphreys, Todd E.; Evans, Brian L.
2018-04-01
We propose a simple low-cost technique that enables civil Global Positioning System (GPS) receivers and other civil global navigation satellite system (GNSS) receivers to reliably detect carry-off spoofing and jamming. The technique, which we call the Power-Distortion detector, classifies received signals as interference-free, multipath-afflicted, spoofed, or jammed according to observations of received power and correlation function distortion. It does not depend on external hardware or a network connection and can be readily implemented on many receivers via a firmware update. Crucially, the detector can with high probability distinguish low-power spoofing from ordinary multipath. In testing against over 25 high-quality empirical data sets yielding over 900,000 separate detection tests, the detector correctly alarms on all malicious spoofing or jamming attacks while maintaining a <0.6% single-channel false alarm rate.
In-Line Sorting of Harumanis Mango Based on External Quality Using Visible Imaging
Ibrahim, Mohd Firdaus; Ahmad Sa’ad, Fathinul Syahir; Zakaria, Ammar; Md Shakaff, Ali Yeon
2016-01-01
The conventional method of grading Harumanis mango is time-consuming, costly and affected by human bias. In this research, an in-line system was developed to classify Harumanis mango using computer vision. The system was able to identify the irregularity of mango shape and its estimated mass. A group of images of mangoes of different size and shape was used as database set. Some important features such as length, height, centroid and parameter were extracted from each image. Fourier descriptor and size-shape parameters were used to describe the mango shape while the disk method was used to estimate the mass of the mango. Four features have been selected by stepwise discriminant analysis which was effective in sorting regular and misshapen mango. The volume from water displacement method was compared with the volume estimated by image processing using paired t-test and Bland-Altman method. The result between both measurements was not significantly different (P > 0.05). The average correct classification for shape classification was 98% for a training set composed of 180 mangoes. The data was validated with another testing set consist of 140 mangoes which have the success rate of 92%. The same set was used for evaluating the performance of mass estimation. The average success rate of the classification for grading based on its mass was 94%. The results indicate that the in-line sorting system using machine vision has a great potential in automatic fruit sorting according to its shape and mass. PMID:27801799
In-Line Sorting of Harumanis Mango Based on External Quality Using Visible Imaging.
Ibrahim, Mohd Firdaus; Ahmad Sa'ad, Fathinul Syahir; Zakaria, Ammar; Md Shakaff, Ali Yeon
2016-10-27
The conventional method of grading Harumanis mango is time-consuming, costly and affected by human bias. In this research, an in-line system was developed to classify Harumanis mango using computer vision. The system was able to identify the irregularity of mango shape and its estimated mass. A group of images of mangoes of different size and shape was used as database set. Some important features such as length, height, centroid and parameter were extracted from each image. Fourier descriptor and size-shape parameters were used to describe the mango shape while the disk method was used to estimate the mass of the mango. Four features have been selected by stepwise discriminant analysis which was effective in sorting regular and misshapen mango. The volume from water displacement method was compared with the volume estimated by image processing using paired t -test and Bland-Altman method. The result between both measurements was not significantly different (P > 0.05). The average correct classification for shape classification was 98% for a training set composed of 180 mangoes. The data was validated with another testing set consist of 140 mangoes which have the success rate of 92%. The same set was used for evaluating the performance of mass estimation. The average success rate of the classification for grading based on its mass was 94%. The results indicate that the in-line sorting system using machine vision has a great potential in automatic fruit sorting according to its shape and mass.
Varao-Sousa, Trish L; Kingstone, Alan
2018-06-26
Mind wandering (MW) reports often rely on individuals responding to specific external thought probes. Researchers have used this probe-caught method almost exclusively, due to its reliability across a wide range of testing situations. However, it remains an open question whether the probe-caught MW rates in more complex settings converge with those for simpler tasks, because of the rather artificial and controlled nature of the probe-caught methodology itself, which is shared across the different settings. To address this issue, we measured MW in a real-world lecture, during which students indicated whether they were mind wandering by simply catching themselves (as one would normally do in real life) or by catching themselves and responding to thought probes. Across three separate lectures, self-caught MW reports were stable and unaffected by the inclusion of MW probes. That the probe rates were similar to those found in prior classroom research and did not affect the self-caught MW rates strongly suggests that the past consistency of probe-caught MW rates across a range of different settings is not an artifact of the thought-probe method. Our study also indicates that the self-caught MW methodology is a reliable way to acquire MW data. The extension of measurement techniques to include students' self-caught reports provides valuable information about how to successfully and naturalistically monitor MW in lecture settings, outside the laboratory.
Development of a New Optical Measuring Set-Up
NASA Astrophysics Data System (ADS)
Miroshnichenko, I. P.; Parinov, I. A.
2018-06-01
The paper proposes a description of the developed optical measuring set-up for the contactless recording and processing of measurement results for small spatial (linear and angular) displacements of control surfaces based on the use of laser technologies and optical interference methods. The proposed set-up is designed to solve all the arising measurement tasks in the study of the physical and mechanical properties of new materials and in the process of diagnosing the state of structural materials by acoustic active methods of nondestructive testing. The structure of the set-up, its constituent parts are described, and the features of construction and functioning during measurements are discussed. New technical solutions for the implementation of the components of the set-up under consideration are obtained. The purpose and description of the original specialized software, used to perform a priori analysis of measurement results, are present, while performing measurements, for a posteriori analysis of measurement results. Moreover, the influences of internal and external disturbance effects on the measurement results and correcting measurement results directly in their implementation are determined. The technical solutions, used in the set-up, are protected by the patents of the Russian Federation for inventions, and software is protected by the certificates of state registration of computer programs. The proposed set-up is intended for use in instrumentation, mechanical engineering, shipbuilding, aviation, energy sector, etc.
Using Spare Logic Resources To Create Dynamic Test Points
NASA Technical Reports Server (NTRS)
Katz, Richard; Kleyner, Igor
2011-01-01
A technique has been devised to enable creation of a dynamic set of test points in an embedded digital electronic system. As a result, electronics contained in an application specific circuit [e.g., gate array, field programmable gate array (FPGA)] can be internally probed, even when contained in a closed housing during all phases of test. In the present technique, the test points are not fixed and limited to a small number; the number of test points can vastly exceed the number of buffers or pins, resulting in a compact footprint. Test points are selected by means of spare logic resources within the ASIC(s) and/or FPGA(s). A register is programmed with a command, which is used to select the signals that are sent off-chip and out of the housing for monitoring by test engineers and external test equipment. The register can be commanded by any suitable means: for example, it could be commanded through a command port that would normally be used in the operation of the system. In the original application of the technique, commanding of the register is performed via a MIL-STD-1553B communication subsystem.
NASA Technical Reports Server (NTRS)
Healy, Frederick M.
1958-01-01
A supplementary investigation to determine the effect of external fuel tanks on the spin and recovery characteristics of a l/28-scale model of the North American FJ-4 airplane has been conducted in the Langley 20-foot free-spinning tunnel. The model had been extensively tested previously (NACA Research Memorandum SL38A29) and therefore only brief tests were made to evaluate the effect of tank installation. Erect spin tests of the model indicate that flat-type spins-are more prevalent with 200-gallon external fuel tanks than with tanks not installed. The recovery technique determined for spins without tanks, rudder reversal to full against the spin accompanied by simultaneous movement of ailerons to full with the spin, is recommended for spins encountered with external tanks installed. If inverted spins are encountered with external tanks installed, the tanks should be jettisoned and recovery attempted by rudder reversal to full against the spin with ailerons maintained at neutral.
Clinical experience of external -route retinal detachment surgery under a surgical microscope.
Xu, Hui
2014-03-01
To evaluate the efficacy of external-route retinal reattachment surgery under a surgical microscope. A total of 86 patients (86 eyes) with rhegmatogenous retinal detachment underwent external-route retinal detachment surgery under a surgical microscope. Drainage of subretinal fluid, transscleral cryotherapy, scleral buckling, and intravitreal injection of gas were performed intraoperatively. Among 85 patients, 81 achieved postoperative retinal re-attachment after the first surgery and 5 after two surgeries. The visual acuity was elevated in 67 patients, unchanged in 15, and decreased in 4. External-route retinal reattachment surgery under a surgical microscope is a convenient procedure for physicians to master and worthy of widespread application in clinical settings.
Parenting and Children's Externalizing Problems in Substance-Abusing Families
ERIC Educational Resources Information Center
Stanger, Catherine; Dumenci, Levent; Kamon, Jody; Burstein, Marcy
2004-01-01
This study tested associations in path models among positive and negative parenting and children's rule-breaking behavior, aggressive and oppositional behavior, and attention problems for families with a drug-dependent parent. A structural model tested relations between parenting and children's externalizing problems for 251 families with 399…
Testing relativistic electron acceleration mechanisms
NASA Astrophysics Data System (ADS)
Green, Janet Carol
2002-09-01
This dissertation tests models of relativistic electron acceleration in the earth's outer radiation belt. The models fall into two categories: external and internal. External acceleration models transport and accelerate electrons from a source region in the outer magnetosphere to the inner magnetosphere. Internal acceleration models accelerate a population of electrons already present in the inner magnetosphere. In this dissertation, we test one specific external acceleration mechanism, perform a general test that differentiates between internal and external acceleration models, and test one promising internal acceleration model. We test the models using Polar-HIST data that we transform into electron phase space density (PSD) as a function of adiabatic invariants. We test the ultra low frequency (ULF) wave enhanced radial diffusion external acceleration mechanism by looking for a causal relationship between increased wave power and increased electron PSD at three L* values. One event with increased wave power at two L* values and no subsequent PSD increase does not support the model suggesting that ULF wave power alone is not sufficient to cause an electron response. Excessive loss of electrons and the duration of wave power do not explain the lack of a PSD enhancement at low L*. We differentiate between internal and external acceleration mechanisms by examining the radial profile of electron PSD. We observe PSD profiles that depend on local time. Nightside profiles are highly dependent on the magnetic field model used to calculate PSD as a function of adiabatic invariants and are not reliable. Dayside PSD profiles are more robust and consistent with internal acceleration of electrons. We test one internal acceleration model, the whistler/electromagnetic ion cyclotron wave model, by comparing observed pitch angle distributions to those predicted by the model using a superposed epoch analysis. The observations show pitch angle distributions corresponding to electrons with energy >=4.0 MeV becoming more peaked at 90° during the storm recovery phase. The observation is consistent with but does not confirm the model. Our tests indicate that relativistic electrons are accelerated by an internal source acceleration mechanism but we do not identify a unique mechanism.
NASA Technical Reports Server (NTRS)
McCoy, Allen H.
1998-01-01
Helicopter external air transportation plays an important role in today's world. For both military and civilian helicopters, external sling load operations offer an efficient and expedient method of handling heavy, oversized cargo. With the ability to reach areas otherwise inaccessible by ground transportation, helicopter external load operations are conducted in industries such as logging, construction, and fire fighting, as well as in support of military tactical transport missions. Historically, helicopter and load combinations have been qualified through flight testing, requiring considerable time and cost. With advancements in simulation and flight test techniques there is potential to substantially reduce costs and increase the safety of helicopter sling load certification. Validated simulation tools make possible accurate prediction of operational flight characteristics before initial flight tests. Real time analysis of test data improves the safety and efficiency of the testing programs. To advance these concepts, the U.S. Army and NASA, in cooperation with the Israeli Air Force and Technion, under a Memorandum of Agreement, seek to develop and validate a numerical model of the UH-60 with sling load and demonstrate a method of near real time flight test analysis. This thesis presents results from flight tests of a U.S. Army Black Hawk helicopter with various external loads. Tests were conducted as the U.S. first phase of this MOA task. The primary load was a container express box (CONEX) which contained a compact instrumentation package. The flights covered the airspeed range from hover to 70 knots. Primary maneuvers were pitch and roll frequency sweeps, steps, and doublets. Results of the test determined the effect of the suspended load on both the aircraft's handling qualities and its control system's stability margins. Included were calculations of the stability characteristics of the load's pendular motion. Utilizing CIFER(R) software, a method for near-real time system identification was also demonstrated during the flight test program.
Cho, Junsang; Cheon, Wonjoong; Ahn, Sanghee; Jung, Hyunuk; Sheen, Heesoon; Park, Hee Chul
2017-01-01
Abstract Target motion–induced uncertainty in particle therapy is more complicated than that in X-ray therapy, requiring more accurate motion management. Therefore, a hybrid motion-tracking system that can track internal tumor motion and as well as an external surrogate of tumor motion was developed. Recently, many correlation tests between internal and external markers in X-ray therapy have been developed; however, the accuracy of such internal/external marker tracking systems, especially in particle therapy, has not yet been sufficiently tested. In this article, the process of installing an in-house hybrid internal/external motion-tracking system is described and the accuracy level of tracking system was acquired. Our results demonstrated that the developed in-house external/internal combined tracking system has submillimeter accuracy, and can be clinically used as a particle therapy system as well as a simulation system for moving tumor treatment. PMID:28201522
Kuzmina, Irina; Ekstrand, Kim R
2015-08-01
To report the long-term effect (18 years) of the Nexö-method, initially implemented in groups of children in Moscow in 1994. Three groups of children were included in the initial study in 1994. This study is a follow-up study of two of the three initial groups: a group of 6-year-olds (test group6 ; control group6 ) and a group of 11-year-olds (test group11 , control group11) , n = 50 individuals in each of the four subgroups. In 2012, >80% of the participants in the two groups (now aged 24 and 28 years old) were re-examined by the original examiner, who was blinded to which group the patients had belonged in the initial study. After re-examination, the participants were interviewed by a person not otherwise attached to the study. Finally, caries data were collected from 100 24-year-olds and 100 28-year-olds who attended the dental school (50%) and private clinic (50%) in Moscow (External control groups24,28 ). The outcome variables of the study were plaque and gingival status, and DMFT/S. In 2012, the control groups24,28 displayed significantly higher plaque scores than the test groups24,28 (P-values < 0.05). No differences were seen regarding gingivitis scores (P-values > 0.41). Mean DMFT/S in 2012 was test group24 = 6.98/10.51, control group24 = 8.84/13.14 (P = 0.02/0.06). External control group24 = 8.89/15.86 (test24 versus external control group24 , P = 0.01/0.007; control24 versus external control group24 , P = 0.94/0.16). Test group28 = 6.74/10.83, control group28 = 8.70/14.48 (P = 0.02/0.008). External control group28 = 9.03/18.06 (test28 versus external control28 , P = 0.03/0.001; control28 versus external control28 , P = 0.68/0.07). The interview indicated that the participants in the test groups were more aware of factors that are considered important for control of caries than participants in the control groups. The data from this group of Moscow citizens suggest a long-term positive effect of the Nexö-method implemented during childhood. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Talevi, Alan; Bellera, Carolina L; Castro, Eduardo A; Bruno-Blanch, Luis E
2007-09-01
A discriminant function based on topological descriptors was derived from a training set composed by anticonvulsants of clinical use or in clinical phase of development and compounds with other therapeutic uses. This model was internally and externally validated and applied in the virtual screening of chemical compounds from the Merck Index 13th. Methylparaben (Nipagin), a preservative widely used in food, cosmetics and pharmaceutics, was signaled as active by the discriminant function and tested in mice in the Maximal Electroshock (MES) test (i.p. administration), according to the NIH Program for Anticonvulsant Drug Development. Based on the results of Methylparaben, Propylparaben (Nipasol), another preservative usually used in association with the former, was also tested. Both methyl and propylparaben were found active in mice at doses of 30, 100, and 300 mg/kg. The discovery of the anticonvulsant activities in the MES test of methylparaben and propylparaben might be useful for the development of new anticonvulsant medications, specially considering the well-known toxicological profile of these drugs.
NASA Astrophysics Data System (ADS)
Talevi, Alan; Bellera, Carolina L.; Castro, Eduardo A.; Bruno-Blanch, Luis E.
2007-09-01
A discriminant function based on topological descriptors was derived from a training set composed by anticonvulsants of clinical use or in clinical phase of development and compounds with other therapeutic uses. This model was internally and externally validated and applied in the virtual screening of chemical compounds from the Merck Index 13th. Methylparaben (Nipagin), a preservative widely used in food, cosmetics and pharmaceutics, was signaled as active by the discriminant function and tested in mice in the Maximal Electroshock (MES) test (i.p. administration), according to the NIH Program for Anticonvulsant Drug Development. Based on the results of Methylparaben, Propylparaben (Nipasol), another preservative usually used in association with the former, was also tested. Both methyl and propylparaben were found active in mice at doses of 30, 100, and 300 mg/kg. The discovery of the anticonvulsant activities in the MES test of methylparaben and propylparaben might be useful for the development of new anticonvulsant medications, specially considering the well-known toxicological profile of these drugs.
NASA Astrophysics Data System (ADS)
Su, Peng; Khreishi, Manal A. H.; Su, Tianquan; Huang, Run; Dominguez, Margaret Z.; Maldonado, Alejandro; Butel, Guillaume; Wang, Yuhao; Parks, Robert E.; Burge, James H.
2014-03-01
A software configurable optical test system (SCOTS) based on deflectometry was developed at the University of Arizona for rapidly, robustly, and accurately measuring precision aspheric and freeform surfaces. SCOTS uses a camera with an external stop to realize a Hartmann test in reverse. With the external camera stop as the reference, a coordinate measuring machine can be used to calibrate the SCOTS test geometry to a high accuracy. Systematic errors from the camera are carefully investigated and controlled. Camera pupil imaging aberration is removed with the external aperture stop. Imaging aberration and other inherent errors are suppressed with an N-rotation test. The performance of the SCOTS test is demonstrated with the measurement results from a 5-m-diameter Large Synoptic Survey Telescope tertiary mirror and an 8.4-m diameter Giant Magellan Telescope primary mirror. The results show that SCOTS can be used as a large-dynamic-range, high-precision, and non-null test method for precision aspheric and freeform surfaces. The SCOTS test can achieve measurement accuracy comparable to traditional interferometric tests.
Shield, Bridget M; Dockrell, Julie E
2008-01-01
While at school children are exposed to various types of noise including external, environmental noise and noise generated within the classroom. Previous research has shown that noise has detrimental effects upon children's performance at school, including reduced memory, motivation, and reading ability. In England and Wales, children's academic performance is assessed using standardized tests of literacy, mathematics, and science. A study has been conducted to examine the impact, if any, of chronic exposure to external and internal noise on the test results of children aged 7 and 11 in London (UK) primary schools. External noise was found to have a significant negative impact upon performance, the effect being greater for the older children. The analysis suggested that children are particularly affected by the noise of individual external events. Test scores were also affected by internal classroom noise, background levels being significantly related to test results. Negative relationships between performance and noise levels were maintained when the data were corrected for socio-economic factors relating to social deprivation, language, and special educational needs. Linear regression analysis has been used to estimate the maximum levels of external and internal noise which allow the schools surveyed to achieve required standards of literacy and numeracy.
Prostate implant reconstruction from C-arm images with motion-compensated tomosynthesis
Dehghan, Ehsan; Moradi, Mehdi; Wen, Xu; French, Danny; Lobo, Julio; Morris, W. James; Salcudean, Septimiu E.; Fichtinger, Gabor
2011-01-01
Purpose: Accurate localization of prostate implants from several C-arm images is necessary for ultrasound-fluoroscopy fusion and intraoperative dosimetry. The authors propose a computational motion compensation method for tomosynthesis-based reconstruction that enables 3D localization of prostate implants from C-arm images despite C-arm oscillation and sagging. Methods: Five C-arm images are captured by rotating the C-arm around its primary axis, while measuring its rotation angle using a protractor or the C-arm joint encoder. The C-arm images are processed to obtain binary seed-only images from which a volume of interest is reconstructed. The motion compensation algorithm, iteratively, compensates for 2D translational motion of the C-arm by maximizing the number of voxels that project on a seed projection in all of the images. This obviates the need for C-arm full pose tracking traditionally implemented using radio-opaque fiducials or external trackers. The proposed reconstruction method is tested in simulations, in a phantom study and on ten patient data sets. Results: In a phantom implanted with 136 dummy seeds, the seed detection rate was 100% with a localization error of 0.86 ± 0.44 mm (Mean ± STD) compared to CT. For patient data sets, a detection rate of 99.5% was achieved in approximately 1 min per patient. The reconstruction results for patient data sets were compared against an available matching-based reconstruction method and showed relative localization difference of 0.5 ± 0.4 mm. Conclusions: The motion compensation method can successfully compensate for large C-arm motion without using radio-opaque fiducial or external trackers. Considering the efficacy of the algorithm, its successful reconstruction rate and low computational burden, the algorithm is feasible for clinical use. PMID:21992346
Economics of regulation: externalities and institutional issues
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kahn, A.E.
In two previous articles, ''Can An Economist Find Happiness Setting Public Utility Rates'' and ''Applications of Economics to Public Utility Rate Structures'', appearing in Public Utilities Fortnightly January 5 and January 19, 1978, respectively, the author summarized his experiences in applying elementary economic principles to the regulation of public utilities in New York state, specifically to setting utility rates. In this article, Mr. Kahn discusses second-best considerations and externalities. He points out that opponents of marginal-cost pricing--particularly of electricity--have in recent years become enthusiastic exponents of the theory of second best. What is required, he feels, is an examination ofmore » how other, most directly pertinent prices in the economy do actually stand relative to their marginal costs. These would be the prices of goods and services for which electricity is a substitute; with which electricity is used as a complement; in whose supply electricity is an input; and which themselves constitute inputs in the production and delivery of electricity. Oil and gas are more complicated cases. External costs, such as abatement requirements, are considered when setting rates. The author points out other regulatory issues to be considered in decision making to conclude this series of articles. (MCW)« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Girka, I. O., E-mail: igorgirka@karazin.ua; Girka, V. O.; Sydora, R. D.
2016-06-15
The influence of non-monochromaticity of an external alternating electric field on excitation of TM eigenmodes at harmonics of the electron cyclotron frequency is considered here. These TM-modes propagate along the plasma interface in a metal waveguide. An external static constant magnetic field is oriented perpendicularly to the plasma interface. The problem is solved theoretically using the kinetic Vlasov-Boltzmann equation for description of plasma particles motion and the Maxwell equations for description of the electromagnetic mode fields. The external alternating electric field is supposed to be a superposition of two waves, whose amplitudes are different and their frequencies correlate as 2:1.more » An infinite set of equations for electric field harmonics of these modes is derived with the aid of nonlinear boundary conditions. This set is solved using the wave packet approach consisting of the main harmonic frequency and two nearest satellite temporal harmonics. Analytical studies of the obtained set of equations allow one to find two different regimes of parametric instability, namely, enhancement and suppression of the instability. Numerical analysis of the instability is carried out for the three first electron cyclotron harmonics.« less
Code of Federal Regulations, 2012 CFR
2012-01-01
... operation when the external power supply is connected to the main electricity supply and the output is (or... external power supply is connected to the main electricity supply and the output is (or “all outputs are... switches, in which the external power supply is (1) connected to the main electricity supply; (2) the...
Code of Federal Regulations, 2013 CFR
2013-01-01
... operation when the external power supply is connected to the main electricity supply and the output is (or... external power supply is connected to the main electricity supply and the output is (or “all outputs are... switches, in which the external power supply is (1) connected to the main electricity supply; (2) the...
Code of Federal Regulations, 2014 CFR
2014-01-01
... operation when the external power supply is connected to the main electricity supply and the output is (or... external power supply is connected to the main electricity supply and the output is (or “all outputs are... switches, in which the external power supply is (1) connected to the main electricity supply; (2) the...
Woodford Guegan, Eleanor; Cook, Andrew
2014-06-01
The European network for Health Technology Assessment Joint Action (EUnetHTA JA) project's overarching objective was to 'establish an effective and sustainable HTA [Health technology assessment] collaboration in Europe that brings added value at the regional, national and European level'. Specific objectives were to develop a strategy and business model for sustainable European collaboration on HTA, develop HTA tools and methods and promote good practice in HTA methods and processes. We describe activities performed on behalf of the National Institute for Health Research HTA programme; evaluating the project processes and developing a data set for a registry of planned clinical studies of relevance to public funders. Annual self-completion online questionnaires were sent to project participants and external stakeholders to identify their views about the project processes. Documentary review was undertaken at the project end on the final technical reports from the work packages to examine whether or not their deliverables had been achieved. The project's impact was assessed by whether or not the deliverables were produced, the objectives met and additional 'added value' generated. The project's effectiveness was evaluated by its processes, communication, administration, workings of individual work packages and involvement of external stakeholders. A two-stage Delphi exercise was undertaken to identify the data elements that should be included in a registry of planned clinical studies of relevance to public funders. The data set was validated by an efficacy testing exercise. High response rates were achieved for the questionnaires sent to project participants and this was attributed to the evidence-based strategy implemented. Response rates to questionnaires sent to external stakeholders were disappointingly lower. Most of the high-level objectives were achieved, although applying the developed tools in practice will be implemented in the European network for Health Technology Assessment Joint Action 2 (EUnetHTA JA2). Most work packages produced their planned deliverables. Networking emerged as one of the main benefits of the project and face-to-face meetings were important. However, the overarching objective did not appear to have been met because there will be a follow-up EUnetHTA JA2 project (reliant on project funding) before the establishment of any permanent network. Twelve organisations from three continents participated in the Delphi exercise to develop the data set. It was demonstrated that a registry for matching pragmatic clinical studies under consideration by funders could be built on a very small data set. This would include 10 unique items, of which five are required to describe a study and the rest are metadata. In the test sample the data set with an appropriate matching rule was able to deliver a sensitivity of between 50% and 100% and a specificity of between 43% and 86% for matching different elements. A number of recommendations have been made for the next EUnetHTA JA2 project and its evaluation. This included that the evaluation of the EUnetHTA JA2 project should extend beyond the end of the project to allow assessment of its impact; that the quality, usability and cost-effectiveness of tools in 'real-world HTA practice' should be assessed and tangible benefits of international networking should be evaluated. It is worth proceeding to develop a database registry aimed at identifying trials in development based on the data set developed. The study was funded by the National Institute for Health Research Health Technology Assessment programme (50%) and the European Union Commission (50%).
Woodford Guegan, Eleanor; Cook, Andrew
2014-01-01
BACKGROUND The European network for Health Technology Assessment Joint Action (EUnetHTA JA) project's overarching objective was to 'establish an effective and sustainable HTA [Health technology assessment] collaboration in Europe that brings added value at the regional, national and European level'. Specific objectives were to develop a strategy and business model for sustainable European collaboration on HTA, develop HTA tools and methods and promote good practice in HTA methods and processes. We describe activities performed on behalf of the National Institute for Health Research HTA programme; evaluating the project processes and developing a data set for a registry of planned clinical studies of relevance to public funders. METHODS Annual self-completion online questionnaires were sent to project participants and external stakeholders to identify their views about the project processes. Documentary review was undertaken at the project end on the final technical reports from the work packages to examine whether or not their deliverables had been achieved. The project's impact was assessed by whether or not the deliverables were produced, the objectives met and additional 'added value' generated. The project's effectiveness was evaluated by its processes, communication, administration, workings of individual work packages and involvement of external stakeholders. A two-stage Delphi exercise was undertaken to identify the data elements that should be included in a registry of planned clinical studies of relevance to public funders. The data set was validated by an efficacy testing exercise. RESULTS AND DISCUSSION High response rates were achieved for the questionnaires sent to project participants and this was attributed to the evidence-based strategy implemented. Response rates to questionnaires sent to external stakeholders were disappointingly lower. Most of the high-level objectives were achieved, although applying the developed tools in practice will be implemented in the European network for Health Technology Assessment Joint Action 2 (EUnetHTA JA2). Most work packages produced their planned deliverables. Networking emerged as one of the main benefits of the project and face-to-face meetings were important. However, the overarching objective did not appear to have been met because there will be a follow-up EUnetHTA JA2 project (reliant on project funding) before the establishment of any permanent network. Twelve organisations from three continents participated in the Delphi exercise to develop the data set. It was demonstrated that a registry for matching pragmatic clinical studies under consideration by funders could be built on a very small data set. This would include 10 unique items, of which five are required to describe a study and the rest are metadata. In the test sample the data set with an appropriate matching rule was able to deliver a sensitivity of between 50% and 100% and a specificity of between 43% and 86% for matching different elements. CONCLUSIONS A number of recommendations have been made for the next EUnetHTA JA2 project and its evaluation. This included that the evaluation of the EUnetHTA JA2 project should extend beyond the end of the project to allow assessment of its impact; that the quality, usability and cost-effectiveness of tools in 'real-world HTA practice' should be assessed and tangible benefits of international networking should be evaluated. It is worth proceeding to develop a database registry aimed at identifying trials in development based on the data set developed. FUNDING The study was funded by the National Institute for Health Research Health Technology Assessment programme (50%) and the European Union Commission (50%). PMID:24913263
Normanno, Nicola; Pinto, Carmine; Castiglione, Francesca; Bardelli, Alberto; Gambacorta, Marcello; Botti, Gerardo; Nappi, Oscar; Siena, Salvatore; Ciardiello, Fortunato; Taddei, Gianluigi; Marchetti, Antonio
2011-01-01
Monoclonal antibodies directed against the epidermal growth factor receptor (EGFR) have been approved for the treatment of patients with metastatic colorectal carcinoma (mCRC) that do not carry KRAS mutations. Therefore, KRAS testing has become mandatory to chose the most appropriate therapy for these patients. In order to guarantee the possibility for mCRC patients to receive an high quality KRAS testing in every Italian region, the Italian Association of Medical Oncology (AIOM) and the Italian Society of Pathology and Cytopathology -Italian division of the International Academy of Pathology (SIAPEC-IAP) started a program to improve KRAS testing. AIOM and SIAPEC identified a large panel of Italian medical oncologists, pathologists and molecular biologists that outlined guidelines for KRAS testing in mCRC patients. These guidelines include specific information on the target patient population, the biological material for molecular analysis, the extraction of DNA, and the methods for the mutational analysis that are summarized in this paper. Following the publication of the guidelines, the scientific societies started an external quality assessment scheme for KRAS testing. Five CRC specimens with known KRAS mutation status were sent to the 59 centers that participated to the program. The samples were validated by three referral laboratories. The participating laboratories were allowed to use their own preferred method for DNA extraction and mutational analysis and were asked to report the results within 4 weeks. The limit to pass the quality assessment was set at 100% of true responses. In the first round, only two centers did not pass (3%). The two centers were offered to participate to a second round and both centers failed again to pass. The results of this first Italian quality assessment for KRAS testing suggest that KRAS mutational analysis is performed with good quality in the majority of Italian centers. © 2011 Normanno et al.
Normanno, Nicola; Pinto, Carmine; Castiglione, Francesca; Bardelli, Alberto; Gambacorta, Marcello; Botti, Gerardo; Nappi, Oscar; Siena, Salvatore; Ciardiello, Fortunato; Taddei, GianLuigi; Marchetti, Antonio
2011-01-01
Background Monoclonal antibodies directed against the epidermal growth factor receptor (EGFR) have been approved for the treatment of patients with metastatic colorectal carcinoma (mCRC) that do not carry KRAS mutations. Therefore, KRAS testing has become mandatory to chose the most appropriate therapy for these patients. Methodology/Principal Findings In order to guarantee the possibility for mCRC patients to receive an high quality KRAS testing in every Italian region, the Italian Association of Medical Oncology (AIOM) and the Italian Society of Pathology and Cytopathology -Italian division of the International Academy of Pathology (SIAPEC-IAP) started a program to improve KRAS testing. AIOM and SIAPEC identified a large panel of Italian medical oncologists, pathologists and molecular biologists that outlined guidelines for KRAS testing in mCRC patients. These guidelines include specific information on the target patient population, the biological material for molecular analysis, the extraction of DNA, and the methods for the mutational analysis that are summarized in this paper. Following the publication of the guidelines, the scientific societies started an external quality assessment scheme for KRAS testing. Five CRC specimens with known KRAS mutation status were sent to the 59 centers that participated to the program. The samples were validated by three referral laboratories. The participating laboratories were allowed to use their own preferred method for DNA extraction and mutational analysis and were asked to report the results within 4 weeks. The limit to pass the quality assessment was set at 100% of true responses. In the first round, only two centers did not pass (3%). The two centers were offered to participate to a second round and both centers failed again to pass. Conclusions The results of this first Italian quality assessment for KRAS testing suggest that KRAS mutational analysis is performed with good quality in the majority of Italian centers. PMID:22216189
Nie, Zhi; Vairavan, Srinivasan; Narayan, Vaibhav A; Ye, Jieping; Li, Qingqin S
2018-01-01
Identification of risk factors of treatment resistance may be useful to guide treatment selection, avoid inefficient trial-and-error, and improve major depressive disorder (MDD) care. We extended the work in predictive modeling of treatment resistant depression (TRD) via partition of the data from the Sequenced Treatment Alternatives to Relieve Depression (STAR*D) cohort into a training and a testing dataset. We also included data from a small yet completely independent cohort RIS-INT-93 as an external test dataset. We used features from enrollment and level 1 treatment (up to week 2 response only) of STAR*D to explore the feature space comprehensively and applied machine learning methods to model TRD outcome at level 2. For TRD defined using QIDS-C16 remission criteria, multiple machine learning models were internally cross-validated in the STAR*D training dataset and externally validated in both the STAR*D testing dataset and RIS-INT-93 independent dataset with an area under the receiver operating characteristic curve (AUC) of 0.70-0.78 and 0.72-0.77, respectively. The upper bound for the AUC achievable with the full set of features could be as high as 0.78 in the STAR*D testing dataset. Model developed using top 30 features identified using feature selection technique (k-means clustering followed by χ2 test) achieved an AUC of 0.77 in the STAR*D testing dataset. In addition, the model developed using overlapping features between STAR*D and RIS-INT-93, achieved an AUC of > 0.70 in both the STAR*D testing and RIS-INT-93 datasets. Among all the features explored in STAR*D and RIS-INT-93 datasets, the most important feature was early or initial treatment response or symptom severity at week 2. These results indicate that prediction of TRD prior to undergoing a second round of antidepressant treatment could be feasible even in the absence of biomarker data.
MacDonald, James; Duerson, Drew
2015-07-01
Baseline assessments using computerized neurocognitive tests are frequently used in the management of sport-related concussions. Such testing is often done on an annual basis in a community setting. Reliability is a fundamental test characteristic that should be established for such tests. Our study examined the test-retest reliability of a computerized neurocognitive test in high school athletes over 1 year. Repeated measures design. Two American high schools. High school athletes (N = 117) participating in American football or soccer during the 2011-2012 and 2012-2013 academic years. All study participants completed 2 baseline computerized neurocognitive tests taken 1 year apart at their respective schools. The test measures performance on 4 cognitive tasks: identification speed (Attention), detection speed (Processing Speed), one card learning accuracy (Learning), and one back speed (Working Memory). Reliability was assessed by measuring the intraclass correlation coefficient (ICC) between the repeated measures of the 4 cognitive tasks. Pearson and Spearman correlation coefficients were calculated as a secondary outcome measure. The measure for identification speed performed best (ICC = 0.672; 95% confidence interval, 0.559-0.760) and the measure for one card learning accuracy performed worst (ICC = 0.401; 95% confidence interval, 0.237-0.542). All tests had marginal or low reliability. In a population of high school athletes, computerized neurocognitive testing performed in a community setting demonstrated low to marginal test-retest reliability on baseline assessments 1 year apart. Further investigation should focus on (1) improving the reliability of individual tasks tested, (2) controlling for external factors that might affect test performance, and (3) identifying the ideal time interval to repeat baseline testing in high school athletes. Computerized neurocognitive tests are used frequently in high school athletes, often within a model of baseline testing of asymptomatic individuals before the start of a sporting season. This study adds to the evidence that suggests in this population such testing may lack sufficient reliability to support clinical decision making.
Instructions to Adopt an External Focus Enhance Muscular Endurance
ERIC Educational Resources Information Center
Marchant, David C.; Greig, Matt; Bullough, Jonathan; Hitchen, Daniel
2011-01-01
The influence of internal (movement focus) and external (outcome focus) attentional-focusing instructions on muscular endurance were investigated using three exercise protocols with experienced exercisers. Twenty-three participants completed a maximal repetition, assisted bench-press test on a Smith's machine. An external focus of attention…
EQUAL-quant: an international external quality assessment scheme for real-time PCR.
Ramsden, Simon C; Daly, Sarah; Geilenkeuser, Wolf-Jochen; Duncan, Graeme; Hermitte, Fabienne; Marubini, Ettore; Neumaier, Michael; Orlando, Claudio; Palicka, Vladimir; Paradiso, Angelo; Pazzagli, Mario; Pizzamiglio, Sara; Verderio, Paolo
2006-08-01
Quantitative gene expression analysis by real-time PCR is important in several diagnostic areas, such as the detection of minimum residual disease in leukemia and the prognostic assessment of cancer patients. To address quality assurance in this technically challenging area, the European Union (EU) has funded the EQUAL project to develop methodologic external quality assessment (EQA) relevant to diagnostic and research laboratories among the EU member states. We report here the results of the EQUAL-quant program, which assesses standards in the use of TaqMan probes, one of the most widely used assays in the implementation of real-time PCR. The EQUAL-quant reagent set was developed to assess the technical execution of a standard TaqMan assay, including RNA extraction, reverse transcription, and real-time PCR quantification of target DNA copy number. The multidisciplinary EQA scheme included 137 participating laboratories from 29 countries. We demonstrated significant differences in performance among laboratories, with 20% of laboratories reporting at least one result lacking in precision and/or accuracy according to the statistical procedures described. No differences in performance were observed for the >10 different testing platforms used by the study participants. This EQA scheme demonstrated both the requirement and demand for external assessment of technical standards in real-time PCR. The reagent design and the statistical tools developed within this project will provide a benchmark for defining acceptable working standards in this emerging technology.
PCDD/PCDF reduction by the co-combustion process.
Lee, Vinci K C; Cheung, Wai-Hung; McKay, Gordon
2008-01-01
A novel process, termed the co-combustion process, has been developed and designed to utilise the thermal treatment of municipal solid waste (MSW) in cement clinker production and reduce PCDD/PCDF emissions. To test the conceptual design; detailed engineering design of the process and equipment was performed and a pilot plant was constructed to treat up to 40 tonnes MSW per day. The novel process features included several units external to the main traditional cement rotary kiln: an external calcinations unit in which the hot gas calcined the limestone thus making significant energy savings for this chemical reaction; the lime generated was used in a second chamber to act as a giant acid gas scrubber to remove SOx and particularly HCl (a source of chloride); an external rotary kiln and secondary combustion unit capable of producing a hot gas at 1200 degrees C; a gas cooler to simulate a boiler turbogenerator set for electricity generation; the incorporation of some of the bottom ash, calcined lime and dust collector solids into the cement clinker. A PCDD/PCDF inventory has been completed for the entire process and measured PCDD/PCDF emissions were 0.001 ng I-TEQ/Nm(3) on average which is 1% of the best practical means [Hong Kong Environmental Protection Department, 2001. A guidance note on the best practicable means for incinerators (municipal waste incineration), BPM12/1] MSW incineration emission limit values.
Duff, Kevin; Suhrie, Kayla R; Dalley, Bonnie C A; Anderson, Jeffrey S; Hoffman, John M
2018-06-08
Within neuropsychology, a number of mathematical formulae (e.g. reliable change index, standardized regression based) have been used to determine if change across time has reliably occurred. When these formulae have been compared, they often produce different results, but 'different' results do not necessarily indicate which formulae are 'best.' The current study sought to further our understanding of change formulae by comparing them to clinically relevant external criteria (amyloid deposition and hippocampal volume). In a sample of 25 older adults with varying levels of cognitive intactness, participants were tested twice across one week with a brief cognitive battery. Seven different change scores were calculated for each participant. An amyloid PET scan (to get a composite of amyloid deposition) and an MRI (to get hippocampal volume) were also obtained. Deviation-based change formulae (e.g. simple discrepancy score, reliable change index with or without correction for practice effects) were all identical in their relationship to the two neuroimaging biomarkers, and all were non-significant. Conversely, regression-based change formulae (e.g. simple and complex indices) showed stronger relationships to amyloid deposition and hippocampal volume. These results highlight the need for external validation of the various change formulae used by neuropsychologists in clinical settings and research projects. The findings also preliminarily suggest that regression-based change formulae may be more relevant than deviation-based change formulae in this context.
ERIC Educational Resources Information Center
Wilkinson, Shaun D.; Penney, Dawn
2016-01-01
Within the UK and internationally, schools are increasingly being encouraged to call on external agencies and draw on the services of individuals, including sport coaches, to "help teach or lead sports within the school setting and out of school time". This trend arises from and has contributed to a changing policy landscape and…
ERIC Educational Resources Information Center
Jones, Darla Renee
2014-01-01
Many adolescent disruptive youth in Pennsylvania are removed from traditional school settings for externalizing behaviors including aggression, defying authority, poor relationships with peers and adults, disruptive behaviors, and bullying. Post-school outcomes of adolescent disruptive youth remain dismal, and these students are the most…
FPGA Sequencer for Radar Altimeter Applications
NASA Technical Reports Server (NTRS)
Berkun, Andrew C.; Pollard, Brian D.; Chen, Curtis W.
2011-01-01
A sequencer for a radar altimeter provides accurate attitude information for a reliable soft landing of the Mars Science Laboratory (MSL). This is a field-programmable- gate-array (FPGA)-only implementation. A table loaded externally into the FPGA controls timing, processing, and decision structures. Radar is memory-less and does not use previous acquisitions to assist in the current acquisition. All cycles complete in exactly 50 milliseconds, regardless of range or whether a target was found. A RAM (random access memory) within the FPGA holds instructions for up to 15 sets. For each set, timing is run, echoes are processed, and a comparison is made. If a target is seen, more detailed processing is run on that set. If no target is seen, the next set is tried. When all sets have been run, the FPGA terminates and waits for the next 50-millisecond event. This setup simplifies testing and improves reliability. A single vertex chip does the work of an entire assembly. Output products require minor processing to become range and velocity. This technology is the heart of the Terminal Descent Sensor, which is an integral part of the Entry Decent and Landing system for MSL. In addition, it is a strong candidate for manned landings on Mars or the Moon.
Trevitt, Sara; Simpson, Sue; Wood, Annette
2016-05-01
Closed-loop artificial pancreas device (APD) systems are externally worn medical devices that are being developed to enable people with type 1 diabetes to regulate their blood glucose levels in a more automated way. The innovative concept of this emerging technology is that hands-free, continuous, glycemic control can be achieved by using digital communication technology and advanced computer algorithms. A horizon scanning review of this field was conducted using online sources of intelligence to identify systems in development. The systems were classified into subtypes according to their level of automation, the hormonal and glycemic control approaches used, and their research setting. Eighteen closed-loop APD systems were identified. All were being tested in clinical trials prior to potential commercialization. Six were being studied in the home setting, 5 in outpatient settings, and 7 in inpatient settings. It is estimated that 2 systems may become commercially available in the EU by the end of 2016, 1 during 2017, and 2 more in 2018. There are around 18 closed-loop APD systems progressing through early stages of clinical development. Only a few of these are currently in phase 3 trials and in settings that replicate real life. © 2015 Diabetes Technology Society.
DOE Office of Scientific and Technical Information (OSTI.GOV)
He, W.; Zhao, H.W.; Liu, Zh.W.
To study the injection of additional electrons from an external electron gun into the plasma of a Penning ionization gauge (PIG) ion source, a test bench for the external electron-beam enhancement of the PIG (E-PIG) ion source was set up. A source magnet assembly was built to satisfy the request for magnetic field configuration of the E-PIG ion source. Numerical calculations have been done to optimize the magnetic field configuration so as to fit the primary electrons to be fed into the PIG discharge chamber along the spreading magnetic field lines. Many possible methods for improving the performance and stabilitymore » of the PIG ion source have been used in the E-PIG ion source, including the use of multicrystal LaB{sub 6} cathode and optimized axial magnetic field. This article presents a detailed design of the E-PIG ion source. Substantial enhancement of ion charge state is expected to be observed which demonstrates that the E-PIG is a viable alternative to other much more costly and difficult to operate devices for the production of intense ion beams of higher charge state.« less
Using beta binomials to estimate classification uncertainty for ensemble models.
Clark, Robert D; Liang, Wenkel; Lee, Adam C; Lawless, Michael S; Fraczkiewicz, Robert; Waldman, Marvin
2014-01-01
Quantitative structure-activity (QSAR) models have enormous potential for reducing drug discovery and development costs as well as the need for animal testing. Great strides have been made in estimating their overall reliability, but to fully realize that potential, researchers and regulators need to know how confident they can be in individual predictions. Submodels in an ensemble model which have been trained on different subsets of a shared training pool represent multiple samples of the model space, and the degree of agreement among them contains information on the reliability of ensemble predictions. For artificial neural network ensembles (ANNEs) using two different methods for determining ensemble classification - one using vote tallies and the other averaging individual network outputs - we have found that the distribution of predictions across positive vote tallies can be reasonably well-modeled as a beta binomial distribution, as can the distribution of errors. Together, these two distributions can be used to estimate the probability that a given predictive classification will be in error. Large data sets comprised of logP, Ames mutagenicity, and CYP2D6 inhibition data are used to illustrate and validate the method. The distributions of predictions and errors for the training pool accurately predicted the distribution of predictions and errors for large external validation sets, even when the number of positive and negative examples in the training pool were not balanced. Moreover, the likelihood of a given compound being prospectively misclassified as a function of the degree of consensus between networks in the ensemble could in most cases be estimated accurately from the fitted beta binomial distributions for the training pool. Confidence in an individual predictive classification by an ensemble model can be accurately assessed by examining the distributions of predictions and errors as a function of the degree of agreement among the constituent submodels. Further, ensemble uncertainty estimation can often be improved by adjusting the voting or classification threshold based on the parameters of the error distribution. Finally, the profiles for models whose predictive uncertainty estimates are not reliable provide clues to that effect without the need for comparison to an external test set.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Valencia, Antoni; Prous, Josep; Mora, Oscar
As indicated in ICH M7 draft guidance, in silico predictive tools including statistically-based QSARs and expert analysis may be used as a computational assessment for bacterial mutagenicity for the qualification of impurities in pharmaceuticals. To address this need, we developed and validated a QSAR model to predict Salmonella t. mutagenicity (Ames assay outcome) of pharmaceutical impurities using Prous Institute's Symmetry℠, a new in silico solution for drug discovery and toxicity screening, and the Mold2 molecular descriptor package (FDA/NCTR). Data was sourced from public benchmark databases with known Ames assay mutagenicity outcomes for 7300 chemicals (57% mutagens). Of these data, 90%more » was used to train the model and the remaining 10% was set aside as a holdout set for validation. The model's applicability to drug impurities was tested using a FDA/CDER database of 951 structures, of which 94% were found within the model's applicability domain. The predictive performance of the model is acceptable for supporting regulatory decision-making with 84 ± 1% sensitivity, 81 ± 1% specificity, 83 ± 1% concordance and 79 ± 1% negative predictivity based on internal cross-validation, while the holdout dataset yielded 83% sensitivity, 77% specificity, 80% concordance and 78% negative predictivity. Given the importance of having confidence in negative predictions, an additional external validation of the model was also carried out, using marketed drugs known to be Ames-negative, and obtained 98% coverage and 81% specificity. Additionally, Ames mutagenicity data from FDA/CFSAN was used to create another data set of 1535 chemicals for external validation of the model, yielding 98% coverage, 73% sensitivity, 86% specificity, 81% concordance and 84% negative predictivity. - Highlights: • A new in silico QSAR model to predict Ames mutagenicity is described. • The model is extensively validated with chemicals from the FDA and the public domain. • Validation tests show desirable high sensitivity and high negative predictivity. • The model predicted 14 reportedly difficult to predict drug impurities with accuracy. • The model is suitable to support risk evaluation of potentially mutagenic compounds.« less
ASVCP guidelines: quality assurance for point-of-care testing in veterinary medicine.
Flatland, Bente; Freeman, Kathleen P; Vap, Linda M; Harr, Kendal E
2013-12-01
Point-of-care testing (POCT) refers to any laboratory testing performed outside the conventional reference laboratory and implies close proximity to patients. Instrumental POCT systems consist of small, handheld or benchtop analyzers. These have potential utility in many veterinary settings, including private clinics, academic veterinary medical centers, the community (eg, remote area veterinary medical teams), and for research applications in academia, government, and industry. Concern about the quality of veterinary in-clinic testing has been expressed in published veterinary literature; however, little guidance focusing on POCT is available. Recognizing this void, the ASVCP formed a subcommittee in 2009 charged with developing quality assurance (QA) guidelines for veterinary POCT. Guidelines were developed through literature review and a consensus process. Major recommendations include (1) taking a formalized approach to POCT within the facility, (2) use of written policies, standard operating procedures, forms, and logs, (3) operator training, including periodic assessment of skills, (4) assessment of instrument analytical performance and use of both statistical quality control and external quality assessment programs, (5) use of properly established or validated reference intervals, (6) and ensuring accurate patient results reporting. Where possible, given instrument analytical performance, use of a validated 13s control rule for interpretation of control data is recommended. These guidelines are aimed at veterinarians and veterinary technicians seeking to improve management of POCT in their clinical or research setting, and address QA of small chemistry and hematology instruments. These guidelines are not intended to be all-inclusive; rather, they provide a minimum standard for maintenance of POCT instruments in the veterinary setting. © 2013 American Society for Veterinary Clinical Pathology and European Society for Veterinary Clinical Pathology.
Attiyeh, Marc A; Chakraborty, Jayasree; Doussot, Alexandre; Langdon-Embry, Liana; Mainarich, Shiana; Gönen, Mithat; Balachandran, Vinod P; D'Angelica, Michael I; DeMatteo, Ronald P; Jarnagin, William R; Kingham, T Peter; Allen, Peter J; Simpson, Amber L; Do, Richard K
2018-04-01
Pancreatic cancer is a highly lethal cancer with no established a priori markers of survival. Existing nomograms rely mainly on post-resection data and are of limited utility in directing surgical management. This study investigated the use of quantitative computed tomography (CT) features to preoperatively assess survival for pancreatic ductal adenocarcinoma (PDAC) patients. A prospectively maintained database identified consecutive chemotherapy-naive patients with CT angiography and resected PDAC between 2009 and 2012. Variation in CT enhancement patterns was extracted from the tumor region using texture analysis, a quantitative image analysis tool previously described in the literature. Two continuous survival models were constructed, with 70% of the data (training set) using Cox regression, first based only on preoperative serum cancer antigen (CA) 19-9 levels and image features (model A), and then on CA19-9, image features, and the Brennan score (composite pathology score; model B). The remaining 30% of the data (test set) were reserved for independent validation. A total of 161 patients were included in the analysis. Training and test sets contained 113 and 48 patients, respectively. Quantitative image features combined with CA19-9 achieved a c-index of 0.69 [integrated Brier score (IBS) 0.224] on the test data, while combining CA19-9, imaging, and the Brennan score achieved a c-index of 0.74 (IBS 0.200) on the test data. We present two continuous survival prediction models for resected PDAC patients. Quantitative analysis of CT texture features is associated with overall survival. Further work includes applying the model to an external dataset to increase the sample size for training and to determine its applicability.
Akakpo, Patrick K; Ulzen-Appiah, Kofi; Agbeno, Evans; Derkyi-Kwarteng, Leonard
2017-12-01
To raise awareness of the existence of a rare type of malignant trophoblastic tumor and discuss the diagnostic challenges and management of this lesion in a low resource setting. A 35 -year -old G 6 P 3 woman was referred to our facility on account of persistent vaginal bleeding due to a suspected incomplete miscarriage with a cervical mass. Her serum β-HCG was elevated (36,900 mIU/ml) and examination showed a bleeding cervical mass. An initial histopathological diagnosis of moderately differentiated squamous cell carcinoma was reviewed to epithelioid trophoblastic tumor resulting in an extra-fascial hysterectomy. A final histopathological diagnosis of hybrid Epithelioid Trophoblastic Tumor and Choriocarcinoma (ETT/CC) was made after external review and immunohistochemistry. She received subsequent chemotherapy. Epithelioid trophoblastic tumor and its hybrids are difficult to diagnose. They may be diagnosed as moderately differentiated squamous cell carcinoma especially in low resource settings where cervical squamous cell carcinoma is relatively more common. A high index of suspicion, a serum β HCG test and close collaboration between clinicians and pathologists can help make the diagnosis. None.
Umaña-Taylor, Adriana J.; Tynes, Brendesha M.; Toomey, Russell B.; Williams, David R.; Mitchell, Kimberly J.
2015-01-01
Guided by a risk and resilience framework, the current study examined the associations between Latino adolescents’ (n = 219; Mage 14.35; SD = 1.75) perceptions of ethnic discrimination in multiple settings (e.g., online, school) and several domains of adjustment (e.g., mental health, academic), and tested whether developmentally salient cultural assets (i.e., ethnic identity) directly promoted youth adjustment or moderated the negative impact of discrimination on adjustment. Each of the 3 ethnic identity components (i.e., exploration, resolution, affirmation) demonstrated evidence of promoting positive outcomes among Latino youth; furthermore, there was some evidence that the promotive effects of affirmation and resolution were significantly stronger for older versus younger adolescents. In addition, with the exception of experiences with discrimination from adults outside of the school setting, there was evidence of ethnic identity interacting with each type of discrimination to predict Latino adolescents’ self-esteem, depressive symptoms, and externalizing problems. Findings suggest directions for future research and identify potential targets for intervention that may prove fruitful in programming efforts with Latino adolescents. PMID:25546597
Manning, William A; Ghosh, Kanishka M; Blain, Alasdair P; Longstaff, Lee M; Rushton, Steven P; Deehan, David J
2017-06-01
Tibial component rotation at time of knee arthroplasty can influence conformity, load transmission across the polyethylene surface, and perhaps ultimately determined survivorship. Optimal tibial component rotation on the cut surface is reliant on standard per operative manual stressing. This subjective assessment aims to balance constraint and stability of the articulation through a full arc of movement. Using a cadaveric model, computer navigation and under defined, previously validated loaded conditions mimicking the in vivo setting, the influence of maximal tibial component external rotation compared with the neutral state was examined for changes in laxity and tibiofemoral continuous load using 3D displacement measurement and an orthosensor continuous load sensor implanted within the polyethylene spacer in a simulated single radius total knee arthroplasty. No significant difference was found throughout arc of motion (0-115 degrees of flexion) for maximal varus and/or valgus or rotatory laxity between the 2 states. The neutral state achieved equivalence for mediolateral load distribution at each point of flexion. We have found that external rotation of the tibial component increased medial compartment load in comparison with the neutral position. Compared with the neutral state, external rotation consistently effected a marginal, but not significant reduction in lateral load under similar loading conditions. The effects were most pronounced in midflexion. On the basis of these findings, we would advocate for the midtibial tubercle point to determine tibial component rotation and caution against component external rotation. Copyright © 2017 Elsevier Inc. All rights reserved.