Sample records for external torso volume

  1. Multimodal image registration of the scoliotic torso for surgical planning

    PubMed Central

    2013-01-01

    Background This paper presents a method that registers MRIs acquired in prone position, with surface topography (TP) and X-ray reconstructions acquired in standing position, in order to obtain a 3D representation of a human torso incorporating the external surface, bone structures, and soft tissues. Methods TP and X-ray data are registered using landmarks. Bone structures are used to register each MRI slice using an articulated model, and the soft tissue is confined to the volume delimited by the trunk and bone surfaces using a constrained thin-plate spline. Results The method is tested on 3 pre-surgical patients with scoliosis and shows a significant improvement, qualitatively and using the Dice similarity coefficient, in fitting the MRI into the standing patient model when compared to rigid and articulated model registration. The determinant of the Jacobian of the registration deformation shows higher variations in the deformation in areas closer to the surface of the torso. Conclusions The novel, resulting 3D full torso model can provide a more complete representation of patient geometry to be incorporated in surgical simulators under development that aim at predicting the effect of scoliosis surgery on the external appearance of the patient’s torso. PMID:23289431

  2. Novel spirometry based on optical surface imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Guang, E-mail: lig2@mskcc.org; Huang, Hailiang; Li, Diana G.

    2015-04-15

    Purpose: To evaluate the feasibility of using optical surface imaging (OSI) to measure the dynamic tidal volume (TV) of the human torso during free breathing. Methods: We performed experiments to measure volume or volume change in geometric and deformable phantoms as well as human subjects using OSI. To assess the accuracy of OSI in volume determination, we performed experiments using five geometric phantoms and two deformable body phantoms and compared the values with those derived from geometric calculations and computed tomography (CT) measurements, respectively. To apply this technique to human subjects, an institutional review board protocol was established and threemore » healthy volunteers were studied. In the human experiment, a high-speed image capture mode of OSI was applied to acquire torso images at 4–5 frames per second, which was synchronized with conventional spirometric measurements at 5 Hz. An in-house MATLAB program was developed to interactively define the volume of interest (VOI), separate the thorax and abdomen, and automatically calculate the thoracic and abdominal volumes within the VOIs. The torso volume change (TV C = ΔV{sub torso} = ΔV{sub thorax} + ΔV{sub abdomen}) was automatically calculated using full-exhalation phase as the reference. The volumetric breathing pattern (BP{sub v} = ΔV{sub thorax}/ΔV{sub torso}) quantifying thoracic and abdominal volume variations was also calculated. Under quiet breathing, TVC should equal the tidal volume measured concurrently by a spirometer with a conversion factor (1.08) accounting for internal and external differences of temperature and moisture. Another MATLAB program was implemented to control the conventional spirometer that was used as the standard. Results: The volumes measured from the OSI imaging of geometric phantoms agreed with the calculated volumes with a discrepancy of 0.0% ± 1.6% (range −1.9% to 2.5%). In measurements from the deformable torso/thorax phantoms, the volume differences measured using OSI imaging and CT imaging were 1.2% ± 2.1% (range −0.5% to 3.6%), with a linear regression fitting (slope = 1.02 and R{sup 2} = 0.999). In volunteers, the relative error in OSI tidal volume measurement was −2.2% ± 4.9% (range −9.2% to 4.8%) and a correlation of r = 0.98 was found with spirometric measurement. The breathing pattern values of the three volunteers were substantially different from each other (BP{sub v} = 0.15, 0.45, and 0.32). Conclusions: This study demonstrates the feasibility of using OSI to measure breathing tidal volumes and breathing patterns with adequate accuracy. This is the first time that dynamic breathing tidal volume as well as breathing patterns is measured using optical surface imaging. The OSI-observed movement of the entire torso could serve as a new respiratory surrogate in the treatment room during radiation therapy.« less

  3. External Versus Two Different Internal Foci of Attention in Long-Distance Throwing.

    PubMed

    Oki, Yuta; Kokubu, Masahiro; Nakagomi, Shiro

    2018-02-01

    The present study examined the influence of attentional focus on performance during a long-distance throwing task. Twelve participants executed three maximum-effort, long-distance baseball throwing attempts in three focus conditions: internal focus on wrist flexion (wrist internal focus), internal focus on the separation between pelvis and upper torso orientations (torso internal focus), and external focus on the ball path (external focus). Compared with the external focus and torso internal focus conditions, performance was poorer in the wrist internal focus condition. Performances were not different in the torso internal and external focus conditions. In addition, attentional focus affected the release angle of the ball but not its initial velocity. Our results reveal that the body part targeted for internal focus of attention and the forcefulness of the motor activity can be as important to motor performance as whether the attention is internal or external.

  4. Emergency department spirometric volume and base deficit delineate risk for torso injury in stable patients

    PubMed Central

    Dunham, C Michael; Sipe, Eilynn K; Peluso, LeeAnn

    2004-01-01

    Background We sought to determine torso injury rates and sensitivities associated with fluid-positive abdominal ultrasound, metabolic acidosis (increased base deficit and lactate), and impaired pulmonary physiology (decreased spirometric volume and PaO2/FiO2). Methods Level I trauma center prospective pilot and post-pilot study (2000–2001) of stable patients. Increased base deficit was < 0.0 in ethanol-negative and ≤ -3.0 in ethanol-positive patients. Increased lactate was > 2.5 mmol/L in ethanol-negative and ≥ 3.0 mmol/L in ethanol-positive patients. Decreased PaO2/FiO2 was < 350 and decreased spirometric volume was < 1.8 L. Results Of 215 patients, 66 (30.7%) had a torso injury (abdominal/pelvic injury n = 35 and/or thoracic injury n = 43). Glasgow Coma Scale score was 14.8 ± 0.5 (13–15). Torso injury rates and sensitivities were: abdominal ultrasound negative and normal base deficit, lactate, PaO2/FiO2, and spirometric volume – 0.0% & 0.0%; normal base deficit and normal spirometric volume – 4.2% & 4.5%; chest/abdominal soft tissue injury – 37.8% & 47.0%; increased lactate – 39.7% & 47.0%; increased base deficit – 41.3% & 75.8%; increased base deficit and/or decreased spirometric volume – 43.8% & 95.5%; decreased PaO2/FiO2 – 48.9% & 33.3%; positive abdominal ultrasound – 62.5% & 7.6%; decreased spirometric volume – 73.4% & 71.2%; increased base deficit and decreased spirometric volume – 82.9% & 51.5%. Conclusions Trauma patients with normal base deficit and spirometric volume are unlikely to have a torso injury. Patients with increased base deficit or lactate, decreased spirometric volume, decreased PaO2/FiO2, or positive FAST have substantial risk for torso injury. Increased base deficit and/or decreased spirometric volume are highly sensitive for torso injury. Base deficit and spirometric volume values are readily available and increase or decrease the suspicion for torso injury. PMID:14731306

  5. Morphometric analysis of torso arterial anatomy with implications for resuscitative aortic occlusion.

    PubMed

    Stannard, Adam; Morrison, Jonathan J; Sharon, Danny J; Eliason, Jonathan L; Rasmussen, Todd E

    2013-08-01

    Hemorrhage is a leading cause of death in military and civilian trauma. Despite the importance of the aorta as a site of hemorrhage control and resuscitative occlusion, detailed knowledge of its morphometry is lacking. The objective of this study was to characterize aortic morphometry in a trauma population, including quantification of distances as well as and diameters and definition of relevant aortic zones. Center line measures were made (Volume Viewer) from contrast computed tomography (CT) scans of male trauma patients (18-45 years). Aortic zones were defined based on branch arteries. Zone I includes left subclavian to celiac; Zone II includes celiac to caudal renal; Zone III includes caudal renal to aortic bifurcation. Zone lengths were calculated and correlated to a novel external measure of torso extent (symphysis pubis to sternal notch). Eighty-eight males (mean [SD], 28 [4] years) had CT scans for the study. The median (interquartile range) lengths (mm) of Zones I, II, and III were 210 mm (202-223 mm), 33 mm (28-38 mm), and 97 mm (91-103 mm), respectively. Median aortic diameters at the left subclavian, celiac, and lowest renal arteries were 21 mm (20-23 mm), 18 mm (16-19 mm), and 15 mm (14-16 mm), respectively, and the terminal aortic diameter was 14 mm (13-15 mm). The correlation of determination for descending aortic length (all zones) against torso extend was r = 0.454. This study provides a morphometric analysis of the aorta in a male population, demonstrating consistency of length and diameter while defining distinct axial zones. Findings suggest that center line aortic distances correlate with a simple, external measure of torso extent. Morphometric study of the aorta using CT data may facilitate the development and implementation of occlusion techniques to manage noncompressible torso, pelvic, and junctional femoral hemorrhage.

  6. Efficacy of thigh volume ratios assessed via stereovision body imaging as a predictor of visceral adipose tissue measured by magnetic resonance imaging

    PubMed Central

    Lee, Jane J; Freeland-Graves, Jeanne H; Pepper, M Reese; Yu, Wurong; Xu, Bugao

    2014-01-01

    Objectives The research examined the efficacy of regional volumes of thigh ratios assessed by stereovision body imaging (SBI) as a predictor of visceral adipose tissue measured by magnetic resonance imaging (MRI). Body measurements obtained via SBI also were utilized to explore disparities of body size and shape in men and women. Method 121 participants were measured for total/regional body volumes and ratios via SBI and abdominal subcutaneous and visceral adipose tissue areas by MRI. Results Thigh to torso and thigh to abdomen-hip volume ratios were the most reliable parameters to predict the accumulation of visceral adipose tissue depots compared to other body measurements. Thigh volume in relation to torso [odds ratios (OR) 0.44] and abdomen-hip (OR 0.41) volumes were negatively associated with increased risks of greater visceral adipose tissue depots, even after controlling for age, gender, and body mass index (BMI). Irrespective of BMI classification, men exhibited greater total body (80.95L vs. 72.41L), torso (39.26L vs. 34.13L), and abdomen-hip (29.01L vs. 25.85L) volumes than women. Women had higher thigh volumes (4.93L vs. 3.99L) and lower-body volume ratios [thigh to total body (0.07 vs. 0.05), thigh to torso (0.15 vs. 0.11), and thigh to abdomen-hip (0.20 vs. 0.15); p<0.05]. Conclusions The unique parameters of the volumes of thigh in relation to torso and abdomen-hip, by SBI were highly effective in predicting visceral adipose tissue deposition. The SBI provided an efficient method for determining body size and shape in men and women via total and regional body volumes and ratios. PMID:25645428

  7. Efficacy of thigh volume ratios assessed via stereovision body imaging as a predictor of visceral adipose tissue measured by magnetic resonance imaging.

    PubMed

    Lee, Jane J; Freeland-Graves, Jeanne H; Pepper, M Reese; Yu, Wurong; Xu, Bugao

    2015-01-01

    The research examined the efficacy of regional volumes of thigh ratios assessed by stereovision body imaging (SBI) as a predictor of visceral adipose tissue measured by magnetic resonance imaging (MRI). Body measurements obtained via SBI also were utilized to explore disparities of body size and shape in men and women. One hundred twenty-one participants were measured for total/regional body volumes and ratios via SBI and abdominal subcutaneous and visceral adipose tissue areas by MRI. Thigh to torso and thigh to abdomen-hip volume ratios were the most reliable parameters to predict the accumulation of visceral adipose tissue depots compared to other body measurements. Thigh volume in relation to torso [odds ratios (OR) 0.44] and abdomen-hip (OR 0.41) volumes were negatively associated with increased risks of greater visceral adipose tissue depots, even after controlling for age, gender, and body mass index (BMI). Irrespective of BMI classification, men exhibited greater total body (80.95L vs. 72.41L), torso (39.26L vs. 34.13L), and abdomen-hip (29.01L vs. 25.85L) volumes than women. Women had higher thigh volumes (4.93L vs. 3.99L) and lower-body volume ratios [thigh to total body (0.07 vs. 0.05), thigh to torso (0.15 vs. 0.11), and thigh to abdomen-hip (0.20 vs. 0.15); P < 0.05]. The unique parameters of the volumes of thigh in relation to torso and abdomen-hip, by SBI were highly effective in predicting visceral adipose tissue deposition. The SBI provided an efficient method for determining body size and shape in men and women via total and regional body volumes and ratios. Am. J. Hum. Biol. 27:445-457, 2015. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  8. Torso and Bowing Arm Three-Dimensional Joint Kinematics of Elite Cellists: Clinical and Pedagogical Implications for Practice.

    PubMed

    Hopper, Luke; Chan, Cliffton; Wijsman, Suzanne; Ackland, Timothy; Visentin, Peter; Alderson, Jacqueline

    2017-06-01

    Elite cello playing requires complex and refined motor control. Cellists are prone to right shoulder and thoracolumbar injuries. Research informing injury management of cellists and cello pedagogy is limited. The aims of this study were to quantify the torso, right shoulder, and elbow joint movement used by elite cellists while performing a fundamental playing task, a C major scale, under two volume conditions. An eight degrees of freedom upper limb biomechanical model was applied to 3D motion capture data of the torso, upper arm, and forearm for 31 cellists with a mean experience of 19.4 yrs (SD 9.1). Two-factor ANOVA compared the joint positions between the four cello strings and two volume conditions. Significant (p<0.05) effects were found for either the string and/or volume conditions across all torso, shoulder, and elbow joint degrees of freedom. The torso was consistently positioned in left rotation from 5.0° (SD 5.6) at the beginning of the scale, increasing to 16.3° (5.5) at its apogee. The greatest mean shoulder flexion, internal rotation, and abduction joint angles were observed when playing at the tip of the bow on the top string (A): 107.2° (11.6), 59.1° (7.1), and -76.9° (15.7), respectively, during loud playing. Elite cellists use specific movement patterns to achieve string crossings and volume regulation during fundamental playing tasks. Implications of the static left-rotated torso posture and high degrees of combined shoulder flexion and internal rotation can be used to inform clinical and pedagogical practices.

  9. Bioimpedance Measurement of Segmental Fluid Volumes and Hemodynamics

    NASA Technical Reports Server (NTRS)

    Montgomery, Leslie D.; Wu, Yi-Chang; Ku, Yu-Tsuan E.; Gerth, Wayne A.; DeVincenzi, D. (Technical Monitor)

    2000-01-01

    Bioimpedance has become a useful tool to measure changes in body fluid compartment volumes. An Electrical Impedance Spectroscopic (EIS) system is described that extends the capabilities of conventional fixed frequency impedance plethysmographic (IPG) methods to allow examination of the redistribution of fluids between the intracellular and extracellular compartments of body segments. The combination of EIS and IPG techniques was evaluated in the human calf, thigh, and torso segments of eight healthy men during 90 minutes of six degree head-down tilt (HDT). After 90 minutes HDT the calf and thigh segments significantly (P < 0.05) lost conductive volume (eight and four percent, respectively) while the torso significantly (P < 0.05) gained volume (approximately three percent). Hemodynamic responses calculated from pulsatile IPG data also showed a segmental pattern consistent with vascular fluid loss from the lower extremities and vascular engorgement in the torso. Lumped-parameter equivalent circuit analyses of EIS data for the calf and thigh indicated that the overall volume decreases in these segments arose from reduced extracellular volume that was not completely balanced by increased intracellular volume. The combined use of IPG and EIS techniques enables noninvasive tracking of multi-segment volumetric and hemodynamic responses to environmental and physiological stresses.

  10. Heat loss regulation: role of appendages and torso in the deer mouse and the white rabbit.

    PubMed

    Conley, K E; Porter, W P

    1985-01-01

    Thermal conductance was subdivided into the component conductances of the appendages and torso using a heat transfer analysis for the deer mouse, Peromyscus maniculatus, and the white rabbit, Oryctolagus cuniculus. Our analysis was based on laboratory measurements of skin temperature and respiratory gas exchange made between air temperatures of 8 and 34 degrees C for the deer mouse, and from published data for the white rabbit. Two series conductances to heat transfer for each appendage and torso were evaluated: internal (hin), for blood flow and tissue conduction to the skin surface, and external (hex), for heat loss from the skin surface to the environment. These two series conductances were represented in a single, total conductance (htot). The limit to htot was set by hex and was reached by the torso htot of both animals. The increase in torso htot observed with air temperature for the mouse suggests that a pilomotor change in fur depth occurred. A control of htot below the limit set by hex was achieved by the hin of each appendage. Elevation of mouse thermal conductance (C) resulted from increases in feet, tail, and torso htot. In contrast, the rabbit showed no change in torso htot between 5 and 30 degrees C and ear htot exclusively increased C over these air temperatures. We suggest that the hyperthermia reported for the rabbit at 35 degrees C resulted from C reaching the physical limit set by torso and near hex. Thus the ear alone adjusted rabbit C, whereas the feet, tail, and the torso contributed to the adjustment of mouse C.

  11. Core Muscle Activity, Exercise Preference, and Perceived Exertion during Core Exercise with Elastic Resistance versus Machine.

    PubMed

    Vinstrup, Jonas; Sundstrup, Emil; Brandt, Mikkel; Jakobsen, Markus D; Calatayud, Joaquin; Andersen, Lars L

    2015-01-01

    Objectives. To investigate core muscle activity, exercise preferences, and perceived exertion during two selected core exercises performed with elastic resistance versus a conventional training machine. Methods. 17 untrained men aged 26-67 years participated in surface electromyography (EMG) measurements of five core muscles during torso-twists performed from left to right with elastic resistance and in the machine, respectively. The order of the exercises was randomized and each exercise consisted of 3 repetitions performed at a 10 RM load. EMG amplitude was normalized (nEMG) to maximum voluntary isometric contraction (MVC). Results. A higher right erector spinae activity in the elastic exercise compared with the machine exercise (50% [95% CI 36-64] versus 32% [95% CI 18-46] nEMG) was found. By contrast, the machine exercise, compared with the elastic exercise, showed higher left external oblique activity (77% [95% CI 64-90] versus 54% [95% CI 40-67] nEMG). For the rectus abdominis, right external oblique, and left erector spinae muscles there were no significant differences. Furthermore, 76% preferred the torso-twist with elastic resistance over the machine exercise. Perceived exertion (Borg CR10) was not significantly different between machine (5.8 [95% CI 4.88-6.72]) and elastic exercise (5.7 [95% CI 4.81-6.59]). Conclusion. Torso-twists using elastic resistance showed higher activity of the erector spinae, whereas torso-twist in the machine resulted in higher activity of the external oblique. For the remaining core muscles the two training modalities induced similar muscular activation. In spite of similar perceived exertion the majority of the participants preferred the exercise using elastic resistance.

  12. Interface Stability Influences Torso Muscle Recruitment and Spinal Load During Pushing Tasks

    PubMed Central

    LEE, P. J.; GRANATA, K. P.

    2006-01-01

    Handle or interface design can influence torso muscle recruitment and spinal load during pushing tasks. The objective of the study was to provide insight into the role of interface stability with regard to torso muscle recruitment and biomechanical loads on the spine. Fourteen subjects generated voluntary isometric trunk flexion force against a rigid interface and similar flexion exertions against an unstable interface, which simulated handle design in a cart pushing task. Normalized electromyographic (EMG) activity in the rectus abdominus, external oblique and internal oblique muscles increased with exertion effort. When using the unstable interface, EMG activity in the internal and external oblique muscle groups was greater than when using the rigid interface. Results agreed with trends from a biomechanical model implemented to predict the muscle activation necessary to generate isometric pushing forces and maintain spinal stability when using the two different interface designs. The co-contraction contributed to increased spinal load when using the unstable interface. It was concluded that handle or interface design and stability may influence spinal load and associated risk of musculoskeletal injury during manual materials tasks that involve pushing exertions. PMID:16540437

  13. Improper trunk rotation sequence is associated with increased maximal shoulder external rotation angle and shoulder joint force in high school baseball pitchers.

    PubMed

    Oyama, Sakiko; Yu, Bing; Blackburn, J Troy; Padua, Darin A; Li, Li; Myers, Joseph B

    2014-09-01

    In a properly coordinated throwing motion, peak pelvic rotation velocity is reached before peak upper torso rotation velocity, so that angular momentum can be transferred effectively from the proximal (pelvis) to distal (upper torso) segment. However, the effects of trunk rotation sequence on pitching biomechanics and performance have not been investigated. The aim of this study was to investigate the effects of trunk rotation sequence on ball speed and on upper extremity biomechanics that are linked to injuries in high school baseball pitchers. The hypothesis was that pitchers with improper trunk rotation sequence would demonstrate lower ball velocity and greater stress to the joint. Descriptive laboratory study. Three-dimensional pitching kinematics data were captured from 72 high school pitchers. Subjects were considered to have proper or improper trunk rotation sequences when the peak pelvic rotation velocity was reached either before or after the peak upper torso rotation velocity beyond the margin of error (±3.7% of the time from stride-foot contact to ball release). Maximal shoulder external rotation angle, elbow extension angle at ball release, peak shoulder proximal force, shoulder internal rotation moment, and elbow varus moment were compared between groups using independent t tests (α < 0.05). Pitchers with improper trunk rotation sequences (n = 33) demonstrated greater maximal shoulder external rotation angle (mean difference, 7.2° ± 2.9°, P = .016) and greater shoulder proximal force (mean difference, 9.2% ± 3.9% body weight, P = .021) compared with those with proper trunk rotation sequences (n = 22). No other variables differed significantly different between groups. High school baseball pitchers who demonstrated improper trunk rotation sequences demonstrated greater maximal shoulder external rotation angle and shoulder proximal force compared with pitchers with proper trunk rotation sequences. Improper sequencing of the trunk and torso alter upper extremity joint loading in ways that may influence injury risk. As such, exercises that reinforce the use of a proper trunk rotation sequence during the pitching motion may reduce the stress placed on the structures around the shoulder joint and lead to the prevention of injuries. © 2014 The Author(s).

  14. Validation of Body Volume Acquisition by Using Elliptical Zone Method.

    PubMed

    Chiu, C-Y; Pease, D L; Fawkner, S; Sanders, R H

    2016-12-01

    The elliptical zone method (E-Zone) can be used to obtain reliable body volume data including total body volume and segmental volumes with inexpensive and portable equipment. The purpose of this research was to assess the accuracy of body volume data obtained from E-Zone by comparing them with those acquired from the 3D photonic scanning method (3DPS). 17 male participants with diverse somatotypes were recruited. Each participant was scanned twice on the same day by a 3D whole-body scanner and photographed twice for the E-Zone analysis. The body volume data acquired from 3DPS was regarded as the reference against which the accuracy of the E-Zone was assessed. The relative technical error of measurement (TEM) of total body volume estimations was around 3% for E-Zone. E-Zone can estimate the segmental volumes of upper torso, lower torso, thigh, shank, upper arm and lower arm accurately (relative TEM<10%) but the accuracy for small segments including the neck, hand and foot were poor. In summary, E-Zone provides a reliable, inexpensive, portable, and simple method to obtain reasonable estimates of total body volume and to indicate segmental volume distribution. © Georg Thieme Verlag KG Stuttgart · New York.

  15. Dynamic Vibrotactile Signals for Forward Collision Avoidance Warning Systems

    PubMed Central

    Meng, Fanxing; Gray, Rob; Ho, Cristy; Ahtamad, Mujthaba

    2015-01-01

    Objective: Four experiments were conducted in order to assess the effectiveness of dynamic vibrotactile collision-warning signals in potentially enhancing safe driving. Background: Auditory neuroscience research has demonstrated that auditory signals that move toward a person are more salient than those that move away. If this looming effect were found to extend to the tactile modality, then it could be utilized in the context of in-car warning signal design. Method: The effectiveness of various vibrotactile warning signals was assessed using a simulated car-following task. The vibrotactile warning signals consisted of dynamic toward-/away-from-torso cues (Experiment 1), dynamic versus static vibrotactile cues (Experiment 2), looming-intensity- and constant-intensity-toward-torso cues (Experiment 3), and static cues presented on the hands or on the waist, having either a low or high vibration intensity (Experiment 4). Results: Braking reaction times (BRTs) were significantly faster for toward-torso as compared to away-from-torso cues (Experiments 1 and 2) and static cues (Experiment 2). This difference could not have been attributed to differential responses to signals delivered to different body parts (i.e., the waist vs. hands; Experiment 4). Embedding a looming-intensity signal into the toward-torso signal did not result in any additional BRT benefits (Experiment 3). Conclusion: Dynamic vibrotactile cues that feel as though they are approaching the torso can be used to communicate information concerning external events, resulting in a significantly faster reaction time to potential collisions. Application: Dynamic vibrotactile warning signals that move toward the body offer great potential for the design of future in-car collision-warning system. PMID:25850161

  16. Ipsilateral wrist-ankle movements in the sagittal plane encoded in extrinsic reference frame.

    PubMed

    Muraoka, Tetsuro; Ishida, Yuki; Obu, Takashi; Crawshaw, Larry; Kanosue, Kazuyuki

    2013-04-01

    When performing oscillatory movements of two joints in the sagittal plane, there is a directional constraint for performing such movements. Previous studies could not distinguish whether the directional constraint reflected movement direction encoded in the extrinsic (outside the body) reference frame or in the intrinsic (the participants' torso/head) reference frame since participants performed coordinated movements in a sitting position where the torso/head was stationary relative to the external world. In order to discern the reference frame in the present study, participants performed paced oscillatory movements of the ipsilateral wrist and ankle in the sagittal plane in a standing position so that the torso/head moved relative to the external world. The coordinated movements were performed in one of two modes of coordination, moving the hand upward concomitant with either ankle plantarflexion or ankle dorsiflexion. The same directional mode relative to extrinsic space was more stable and accurate as compared with the opposite directional mode. When forearm position was changed from the pronated position to the supinated position, similar results were obtained, indicating that the results were independent of a particular coupling of muscles. These findings suggest that the directional constraint on ipsilateral joints movements in the sagittal plane reflects movement direction encoded in the extrinsic reference frame. Copyright © 2013 Elsevier Ireland Ltd and the Japan Neuroscience Society. All rights reserved.

  17. Immediate compensation for variations in self-generated Coriolis torques related to body dynamics and carried objects

    PubMed Central

    DiZio, Paul; Lackner, James R.

    2013-01-01

    We have previously shown that the Coriolis torques that result when an arm movement is performed during torso rotation do not affect movement trajectory. Our purpose in the present study was to examine whether torso motion-induced Coriolis and other interaction torques are counteracted during a turn and reach (T&R) movement when the effective mass of the hand is augmented, and whether the dominant arm has an advantage in coordinating intersegmental dynamics as predicted by the dynamic dominance hypothesis (Sainburg RL. Exp Brain Res 142: 241–258, 2002). Subjects made slow and fast T&R movements in the dark to just extinguished targets with either arm, while holding or not holding a 454-g object. Movement endpoints were equally accurate at both speeds, with either hand, and in both weight conditions, but subjects tended to angularly undershoot and produce more variable endpoints for targets requiring greater torso rotation. There were no changes in endpoint accuracy or trajectory deviation over repeated movements. The dominant right arm was more stable in its control of trajectory direction across targets, whereas the nondominant left arm had an improved ability to stop accurately on the target for higher levels of interaction torques. The trajectories to more eccentric targets were straighter when performed at higher speeds but slightly more deviated when subjects held the weight. Subjects did not slow their torso velocity or change the timing of the arm and torso velocities when holding the weight, although there was a slight decrease in their hand velocity relative to the torso. The delay between the onsets of torso and finger movements was almost twice as large for the right arm than the left, suggesting the right arm was better able to account for torso rotation in the arm movement. Holding the weight increased the peak Coriolis torque by 40% at the shoulder and 45% at the elbow and, for the most eccentric target, increased the peak net torque by 12% at the shoulder and 34% at the elbow. In accordance with Sainburg's dynamic dominance hypothesis, the right arm exhibited an advantage for coordinating intersegmental dynamics, showing a more stable finger velocity in relation to the torso across targets, decreasing error variability with movement speed, and more synchronized peaks of finger relative and torso angular velocities in conditions with greater joint torque requirements. The arm used had little effect on the movement path and the magnitude of the joint torques in any of the conditions. These results indicate that compensations for forthcoming Coriolis torque variations take into account the dynamic properties of the body and of external objects, as well as the planned velocities of the torso and arm. PMID:23803330

  18. Immediate compensation for variations in self-generated Coriolis torques related to body dynamics and carried objects.

    PubMed

    Pigeon, Pascale; Dizio, Paul; Lackner, James R

    2013-09-01

    We have previously shown that the Coriolis torques that result when an arm movement is performed during torso rotation do not affect movement trajectory. Our purpose in the present study was to examine whether torso motion-induced Coriolis and other interaction torques are counteracted during a turn and reach (T&R) movement when the effective mass of the hand is augmented, and whether the dominant arm has an advantage in coordinating intersegmental dynamics as predicted by the dynamic dominance hypothesis (Sainburg RL. Exp Brain Res 142: 241-258, 2002). Subjects made slow and fast T&R movements in the dark to just extinguished targets with either arm, while holding or not holding a 454-g object. Movement endpoints were equally accurate at both speeds, with either hand, and in both weight conditions, but subjects tended to angularly undershoot and produce more variable endpoints for targets requiring greater torso rotation. There were no changes in endpoint accuracy or trajectory deviation over repeated movements. The dominant right arm was more stable in its control of trajectory direction across targets, whereas the nondominant left arm had an improved ability to stop accurately on the target for higher levels of interaction torques. The trajectories to more eccentric targets were straighter when performed at higher speeds but slightly more deviated when subjects held the weight. Subjects did not slow their torso velocity or change the timing of the arm and torso velocities when holding the weight, although there was a slight decrease in their hand velocity relative to the torso. The delay between the onsets of torso and finger movements was almost twice as large for the right arm than the left, suggesting the right arm was better able to account for torso rotation in the arm movement. Holding the weight increased the peak Coriolis torque by 40% at the shoulder and 45% at the elbow and, for the most eccentric target, increased the peak net torque by 12% at the shoulder and 34% at the elbow. In accordance with Sainburg's dynamic dominance hypothesis, the right arm exhibited an advantage for coordinating intersegmental dynamics, showing a more stable finger velocity in relation to the torso across targets, decreasing error variability with movement speed, and more synchronized peaks of finger relative and torso angular velocities in conditions with greater joint torque requirements. The arm used had little effect on the movement path and the magnitude of the joint torques in any of the conditions. These results indicate that compensations for forthcoming Coriolis torque variations take into account the dynamic properties of the body and of external objects, as well as the planned velocities of the torso and arm.

  19. Method for inducing hypothermia

    DOEpatents

    Becker, Lance B.; Hoek, Terry Vanden; Kasza, Kenneth E.

    2003-04-15

    Systems for phase-change particulate slurry cooling equipment and methods to induce hypothermia in a patient through internal and external cooling are provided. Subcutaneous, intravascular, intraperitoneal, gastrointestinal, and lung methods of cooling are carried out using saline ice slurries or other phase-change slurries compatible with human tissue. Perfluorocarbon slurries or other slurry types compatible with human tissue are used for pulmonary cooling. And traditional external cooling methods are improved by utilizing phase-change slurry materials in cooling caps and torso blankets.

  20. Method for inducing hypothermia

    DOEpatents

    Becker, Lance B [Chicago, IL; Hoek, Terry Vanden [Chicago, IL; Kasza, Kenneth E [Palos Park, IL

    2008-09-09

    Systems for phase-change particulate slurry cooling equipment and methods to induce hypothermia in a patient through internal and external cooling are provided. Subcutaneous, intravascular, intraperitoneal, gastrointestinal, and lung methods of cooling are carried out using saline ice slurries or other phase-change slurries compatible with human tissue. Perfluorocarbon slurries or other slurry types compatible with human tissue are used for pulmonary cooling. And traditional external cooling methods are improved by utilizing phase-change slurry materials in cooling caps and torso blankets.

  1. Method for inducing hypothermia

    DOEpatents

    Becker, Lance B.; Hoek, Terry Vanden; Kasza, Kenneth E.

    2005-11-08

    Systems for phase-change particulate slurry cooling equipment and methods to induce hypothermia in a patient through internal and external cooling are provided. Subcutaneous, intravascular, intraperitoneal, gastrointestinal, and lung methods of cooling are carried out using saline ice slurries or other phase-change slurries compatible with human tissue. Perfluorocarbon slurries or other slurry types compatible with human tissue are used for pulmonary cooling. And traditional external cooling methods are improved by utilizing phase-change slurry materials in cooling caps and torso blankets.

  2. Value of epicardial potential maps in localizing pre-excitation sites for radiofrequency ablation. A simulation study

    NASA Astrophysics Data System (ADS)

    Hren, Rok

    1998-06-01

    Using computer simulations, we systematically investigated the limitations of an inverse solution that employs the potential distribution on the epicardial surface as an equivalent source model in localizing pre-excitation sites in Wolff-Parkinson-White syndrome. A model of the human ventricular myocardium that features an anatomically accurate geometry, an intramural rotating anisotropy and a computational implementation of the excitation process based on electrotonic interactions among cells, was used to simulate body surface potential maps (BSPMs) for 35 pre-excitation sites positioned along the atrioventricular ring. Two individualized torso models were used to account for variations in torso boundaries. Epicardial potential maps (EPMs) were computed using the L-curve inverse solution. The measure for accuracy of the localization was the distance between a position of the minimum in the inverse EPMs and the actual site of pre-excitation in the ventricular model. When the volume conductor properties and lead positions of the torso were precisely known and the measurement noise was added to the simulated BSPMs, the minimum in the inverse EPMs was at 12 ms after the onset on average within cm of the pre-excitation site. When the standard torso model was used to localize the sites of onset of the pre-excitation sequence initiated in individualized male and female torso models, the mean distance between the minimum and the pre-excitation site was cm for the male torso and cm for the female torso. The findings of our study indicate that a location of the minimum in EPMs computed using the inverse solution can offer non-invasive means for pre-interventional planning of the ablative treatment.

  3. Diaphragm electrical activity during negative lower torso pressure in quadriplegic men.

    PubMed

    Banzett, R B; Inbar, G F; Brown, R; Goldman, M; Rossier, A; Mead, J

    1981-09-01

    We recorded the diaphragm electromyogram (EMG) of quadriplegic men before and during exposure of the lower torso to continuous negative pressure, which caused shortening of the inspiratory muscles by expanding the respiratory system by one tidal volume. The moving-time-averaged diaphragm EMG was larger during expansion of the respiratory system. When we repeated the experiment with subjects who breathed through a mouthpiece, we found qualitatively similar EMG changes and little or no change in tidal volume or end-tidal CO2 partial pressure. When the pressure was applied or removed rapidly, changes in EMG occurred within one or two breaths. Because end-tidal CO2 partial pressure did not increase, and because the response was rapid, we suggest that the response results from proprioceptive, rather than chemoreceptive, reflexes. As most of these men had complete spinal lesions at C6 or C7 the afferent pathways are likely to be vagal or phrenic.

  4. Landmark-guided diffeomorphic demons algorithm and its application to automatic segmentation of the whole spine and pelvis in CT images.

    PubMed

    Hanaoka, Shouhei; Masutani, Yoshitaka; Nemoto, Mitsutaka; Nomura, Yukihiro; Miki, Soichiro; Yoshikawa, Takeharu; Hayashi, Naoto; Ohtomo, Kuni; Shimizu, Akinobu

    2017-03-01

    A fully automatic multiatlas-based method for segmentation of the spine and pelvis in a torso CT volume is proposed. A novel landmark-guided diffeomorphic demons algorithm is used to register a given CT image to multiple atlas volumes. This algorithm can utilize both grayscale image information and given landmark coordinate information optimally. The segmentation has four steps. Firstly, 170 bony landmarks are detected in the given volume. Using these landmark positions, an atlas selection procedure is performed to reduce the computational cost of the following registration. Then the chosen atlas volumes are registered to the given CT image. Finally, voxelwise label voting is performed to determine the final segmentation result. The proposed method was evaluated using 50 torso CT datasets as well as the public SpineWeb dataset. As a result, a mean distance error of [Formula: see text] and a mean Dice coefficient of [Formula: see text] were achieved for the whole spine and the pelvic bones, which are competitive with other state-of-the-art methods. From the experimental results, the usefulness of the proposed segmentation method was validated.

  5. [Conservative treatment of idiopathic scoliosis with effective braces: early response to trunk asymmetry may avoid curvature progress].

    PubMed

    Matussek, J; Dingeldey, E; Wagner, F; Rezai, G; Nahr, K

    2014-07-01

    Vertical posture of the growing child requires minute central nervous control mechanisms in order to maintain symmetry of the torso in its various activities. Scoliosis describes a constant deviation in the frontal, transverse and sagittal planes from the dynamic symmetry of the trunk. Early intervention with effective bracing, physiotherapy and sports can reverse curve progression during growth spurts, once these are identified in screening. Modern braces have a derotating and reducing effect (mirror effect) on asymmetric body volumes, thus influencing the growing torso and restoring lasting symmetry. Recent data support the use of braces to reverse progressing scoliosis.

  6. 49 CFR 572.135 - Upper and lower torso assemblies and torso flexion test procedure.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 7 2014-10-01 2014-10-01 false Upper and lower torso assemblies and torso flexion... torso assemblies and torso flexion test procedure. (a) Upper/lower torso assembly. The test objective is... (drawing 880105-434), on resistance to articulation between the upper torso assembly (drawing 880105-300...

  7. 49 CFR 572.135 - Upper and lower torso assemblies and torso flexion test procedure.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 7 2012-10-01 2012-10-01 false Upper and lower torso assemblies and torso flexion... torso assemblies and torso flexion test procedure. (a) Upper/lower torso assembly. The test objective is... (drawing 880105-434), on resistance to articulation between the upper torso assembly (drawing 880105-300...

  8. 49 CFR 572.135 - Upper and lower torso assemblies and torso flexion test procedure.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 7 2013-10-01 2013-10-01 false Upper and lower torso assemblies and torso flexion... torso assemblies and torso flexion test procedure. (a) Upper/lower torso assembly. The test objective is... (drawing 880105-434), on resistance to articulation between the upper torso assembly (drawing 880105-300...

  9. 49 CFR 572.135 - Upper and lower torso assemblies and torso flexion test procedure.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 7 2011-10-01 2011-10-01 false Upper and lower torso assemblies and torso flexion... torso assemblies and torso flexion test procedure. (a) Upper/lower torso assembly. The test objective is... (drawing 880105-434), on resistance to articulation between the upper torso assembly (drawing 880105-300...

  10. The effects of actuator selection on non-volitional postural responses to torso-based vibrotactile stimulation

    PubMed Central

    2013-01-01

    Background Torso-based vibrotactile feedback may significantly reduce postural sway in balance-compromised adults during quiet standing or in response to perturbations. However, natural non-volitional postural responses to vibrotactile stimulation applied to the torso remain unknown. Methods The primary goal of this study was to determine, for two types of actuators (tactors) and in the absence of instruction, whether vibrotactile stimulation induces a directional postural shift as a function of stimulation location. Eleven healthy young adults (20 – 29 years old) were asked to maintain an upright erect posture with feet hip-width apart and eyes closed. Two types of tactors, Tactaid and C2, which differ in design and stimulation strength, were placed on the skin over the right and left external oblique, internal oblique, and erector spinae muscles in a horizontal plane corresponding approximately to the L4/L5 level. Each tactor of the same type was activated twice randomly for each individual location and twice simultaneously for all locations at a frequency of 250 Hz for a period of 5 s. Results Vibration applied over the internal oblique and erector spinae muscle locations induced a postural shift in the direction of the stimulation regardless of the tactor type. For the aforementioned four locations, the root-mean-square (RMS) and power spectral density (PSD) of the body sway in both the A/P and M/L directions were also significantly greater during the vibration than before or after, and were greater for the C2 tactors than for the Tactaid tactors. However, simultaneous activation of all tactors or those over the external oblique muscle locations did not produce significant postural responses regardless of the tactor type. Conclusion The results suggest that the use of a torso-based vibrotactile sensory augmentation display should carefully consider the tactor type as well as the instruction of corrective movements. Attractive instructional cues (“move in the direction of the vibration”) are compatible with the observed non-volitional response to stimulation and may facilitate postural adjustments during vibrotactile biofeedback balance applications. PMID:23406013

  11. 49 CFR 572.125 - Upper and lower torso assemblies and torso flexion test procedure.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 7 2014-10-01 2014-10-01 false Upper and lower torso assemblies and torso flexion... assemblies and torso flexion test procedure. (a) Upper/lower torso assembly. The test objective is to...), and abdominal insert (drawing 127-8210), on resistance to articulation between upper torso assembly...

  12. 49 CFR 572.125 - Upper and lower torso assemblies and torso flexion test procedure.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 7 2011-10-01 2011-10-01 false Upper and lower torso assemblies and torso flexion... assemblies and torso flexion test procedure. (a) Upper/lower torso assembly. The test objective is to...), and abdominal insert (drawing 127-8210), on resistance to articulation between upper torso assembly...

  13. 49 CFR 572.125 - Upper and lower torso assemblies and torso flexion test procedure.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 7 2012-10-01 2012-10-01 false Upper and lower torso assemblies and torso flexion... assemblies and torso flexion test procedure. (a) Upper/lower torso assembly. The test objective is to...), and abdominal insert (drawing 127-8210), on resistance to articulation between upper torso assembly...

  14. 49 CFR 572.125 - Upper and lower torso assemblies and torso flexion test procedure.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 7 2013-10-01 2013-10-01 false Upper and lower torso assemblies and torso flexion... assemblies and torso flexion test procedure. (a) Upper/lower torso assembly. The test objective is to...), and abdominal insert (drawing 127-8210), on resistance to articulation between upper torso assembly...

  15. 49 CFR 572.165 - Upper and lower torso assemblies and torso flexion test procedure.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 7 2012-10-01 2012-10-01 false Upper and lower torso assemblies and torso flexion... assemblies and torso flexion test procedure. (a) Upper/lower torso assembly. The test objective is to... (specified in 49 CFR 572.125(a)), on resistance to articulation between the upper torso assembly (drawing 167...

  16. 49 CFR 572.165 - Upper and lower torso assemblies and torso flexion test procedure.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 7 2013-10-01 2013-10-01 false Upper and lower torso assemblies and torso flexion... assemblies and torso flexion test procedure. (a) Upper/lower torso assembly. The test objective is to... (specified in 49 CFR 572.125(a)), on resistance to articulation between the upper torso assembly (drawing 167...

  17. 49 CFR 572.165 - Upper and lower torso assemblies and torso flexion test procedure.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 7 2010-10-01 2010-10-01 false Upper and lower torso assemblies and torso flexion... assemblies and torso flexion test procedure. (a) Upper/lower torso assembly. The test objective is to... (specified in 49 CFR 572.125(a)), on resistance to articulation between the upper torso assembly (drawing 167...

  18. 49 CFR 572.165 - Upper and lower torso assemblies and torso flexion test procedure.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 7 2011-10-01 2011-10-01 false Upper and lower torso assemblies and torso flexion... assemblies and torso flexion test procedure. (a) Upper/lower torso assembly. The test objective is to... (specified in 49 CFR 572.125(a)), on resistance to articulation between the upper torso assembly (drawing 167...

  19. 49 CFR 572.165 - Upper and lower torso assemblies and torso flexion test procedure.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 7 2014-10-01 2014-10-01 false Upper and lower torso assemblies and torso flexion... assemblies and torso flexion test procedure. (a) Upper/lower torso assembly. The test objective is to... (specified in 49 CFR 572.125(a)), on resistance to articulation between the upper torso assembly (drawing 167...

  20. Respiratory function monitoring using a real-time three-dimensional fiber-optic shaping sensing scheme based upon fiber Bragg gratings

    NASA Astrophysics Data System (ADS)

    Allsop, Thomas; Bhamber, Ranjeet; Lloyd, Glynn; Miller, Martin R.; Dixon, Andrew; Webb, David; Ania Castañón, Juan Diego; Bennion, Ian

    2012-11-01

    An array of in-line curvature sensors on a garment is used to monitor the thoracic and abdominal movements of a human during respiration. The results are used to obtain volumetric changes of the human torso in agreement with a spirometer used simultaneously at the mouth. The array of 40 in-line fiber Bragg gratings is used to produce 20 curvature sensors at different locations, each sensor consisting of two fiber Bragg gratings. The 20 curvature sensors and adjoining fiber are encapsulated into a low-temperature-cured synthetic silicone. The sensors are wavelength interrogated by a commercially available system from Moog Insensys, and the wavelength changes are calibrated to recover curvature. A three-dimensional algorithm is used to generate shape changes during respiration that allow the measurement of absolute volume changes at various sections of the torso. It is shown that the sensing scheme yields a volumetric error of 6%. Comparing the volume data obtained from the spirometer with the volume estimated with the synchronous data from the shape-sensing array yielded a correlation value 0.86 with a Pearson's correlation coefficient p<0.01.

  1. The role of upper torso and pelvis rotation in driving performance during the golf swing.

    PubMed

    Myers, Joseph; Lephart, Scott; Tsai, Yung-Shen; Sell, Timothy; Smoliga, James; Jolly, John

    2008-01-15

    While the role of the upper torso and pelvis in driving performance is anecdotally appreciated by golf instructors, their actual biomechanical role is unclear. The aims of this study were to describe upper torso and pelvis rotation and velocity during the golf swing and determine their role in ball velocity. One hundred recreational golfers underwent a biomechanical golf swing analysis using their own driver. Upper torso and pelvic rotation and velocity, and torso-pelvic separation and velocity, were measured for each swing. Ball velocity was assessed with a golf launch monitor. Group differences (groups based on ball velocity) and moderate relationships (r > or = 0.50; P < 0.001) were observed between an increase in ball velocity and the following variables: increased torso-pelvic separation at the top of the swing, maximum torso-pelvic separation, maximum upper torso rotation velocity, upper torso rotational velocity at lead arm parallel and last 40 ms before impact, maximum torso-pelvic separation velocity and torso-pelvic separation velocity at both lead arm parallel and at the last 40 ms before impact. Torso-pelvic separation contributes to greater upper torso rotation velocity and torso-pelvic separation velocity during the downswing, ultimately contributing to greater ball velocity. Golf instructors can consider increasing ball velocity by maximizing separation between the upper torso and pelvis at the top of and initiation of the downswing.

  2. Computer Simulation of an Aircraft Seat and Occupant in a Crash Environment. Volume 2. Program SOM-LA (Seat/Occupant Model - Light Aircraft) User Manual

    DTIC Science & Technology

    1983-03-01

    349A9 3 Figure A-8. Program SOM-LA body segment dimensions. _ t m • •m v m--, • v_ ,• W:•---:x:--:’ ,•-•• •--" ..- • % ’"•Z>L r -L.J :•":’. 7=- 2 J7.ŗZ...offset from the mid-saggital plane, and the anterior offset of the major upper body segment (lower torso, upper torso, and head) center of masses from... body rotation) energy-absorbing scat model. (See figure A-lI for a detailed de- scription of the parameters.) FORMAT AND EXAMPLE: 2 3 4 6 6 7 1 0123 4

  3. 49 CFR 572.145 - Upper and lower torso assemblies and torso flexion test procedure.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 7 2012-10-01 2012-10-01 false Upper and lower torso assemblies and torso flexion... assemblies and torso flexion test procedure. (a) The test objective is to determine the resistance of the... upper and lower halves of the torso assembly (refer to § 572.140(a)(1)(iv)). (b)(1) When the upper half...

  4. 49 CFR 572.145 - Upper and lower torso assemblies and torso flexion test procedure.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 7 2011-10-01 2011-10-01 false Upper and lower torso assemblies and torso flexion... assemblies and torso flexion test procedure. (a) The test objective is to determine the resistance of the... upper and lower halves of the torso assembly (refer to § 572.140(a)(1)(iv)). (b)(1) When the upper half...

  5. 49 CFR 572.145 - Upper and lower torso assemblies and torso flexion test procedure.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 7 2013-10-01 2013-10-01 false Upper and lower torso assemblies and torso flexion... assemblies and torso flexion test procedure. (a) The test objective is to determine the resistance of the... upper and lower halves of the torso assembly (refer to § 572.140(a)(1)(iv)). (b)(1) When the upper half...

  6. 49 CFR 572.145 - Upper and lower torso assemblies and torso flexion test procedure.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 7 2014-10-01 2014-10-01 false Upper and lower torso assemblies and torso flexion... assemblies and torso flexion test procedure. (a) The test objective is to determine the resistance of the... upper and lower halves of the torso assembly (refer to § 572.140(a)(1)(iv)). (b)(1) When the upper half...

  7. Effects of Deployment on Musculoskeletal and Physiological Characteristics and Balance.

    PubMed

    Nagai, Takashi; Abt, John P; Sell, Timothy C; Keenan, Karen A; McGrail, Mark A; Smalley, Brian W; Lephart, Scott M

    2016-09-01

    Despite many nonbattle injuries reported during deployment, few studies have been conducted to evaluate the effects of deployment on musculoskeletal and physiological characteristics and balance. A total of 35 active duty U.S. Army Soldiers participated in laboratory testing before and after deployment to Afghanistan. The following measures were obtained for each Soldier: shoulder, trunk, hip, knee, and ankle strength and range of motion (ROM), balance, body composition, aerobic capacity, and anaerobic power/capacity. Additionally, Soldiers were asked about their physical activity and load carriage. Paired t tests or Wilcoxon tests with an α = 0.05 set a priori were used for statistical analyses. Shoulder external rotation ROM, torso rotation ROM, ankle dorsiflexion ROM, torso rotation strength, and anaerobic power significantly increased following deployment (p < 0.05). Shoulder extension ROM, shoulder external rotation strength, and eyes-closed balance (p < 0.05) were significantly worse following deployment. The majority of Soldiers (85%) engaged in physical activity. In addition, 58% of Soldiers reported regularly carrying a load (22 kg average). The deployment-related changes in musculoskeletal and physiological characteristics and balance as well as physical activity and load carriage during deployment may assist with proper preparation with the intent to optimize tactical readiness and mitigate injury risk. Reprint & Copyright © 2016 Association of Military Surgeons of the U.S.

  8. Characterization of Human Torso Vascular Morphometry in Normotensive and Hypotensive Trauma Patients

    DTIC Science & Technology

    2015-07-01

    Aorta Wall Measures Merged for Analysis Landmarks & User-aided Segmentation 5cm Volume...with Centerline Measures AORTA PROCESSING VENA CAVA PROCESSING Basic Morphomics Scan Identification Aorta Centerline Segmented Aorta and Vena...Analysis 49 Data Presentation Aorta  Radius  Popula/on       Normotensive   Hypotensive  

  9. Estimating radiofrequency power deposition in body NMR imaging.

    PubMed

    Bottomley, P A; Redington, R W; Edelstein, W A; Schenck, J F

    1985-08-01

    Simple theoretical estimates of the average, maximum, and spatial variation of the radiofrequency power deposition (specific absorption rate) during hydrogen nuclear magnetic resonance imaging are deduced for homogeneous spheres and for cylinders of biological tissue with a uniformly penetrating linear rf field directed axially and transverse to the cylindrical axis. These are all simple scalar multiples of the expression for the cylinder in an axial field published earlier (Med. Phys. 8, 510 (1981]. Exact solutions for the power deposition in the cylinder with axial (Phys. Med. Biol. 23, 630 (1978] and transversely directed rf field are also presented, and the spatial variation of power deposition in head and body models is examined. In the exact models, the specific absorption rates decrease rapidly and monotonically with decreasing radius despite local increases in rf field amplitude. Conversion factors are provided for calculating the power deposited by Gaussian and sinc-modulated rf pulses used for slice selection in NMR imaging, relative to rectangular profiled pulses. Theoretical estimates are compared with direct measurements of the total power deposited in the bodies of nine adult males by a 63-MHz body-imaging system with transversely directed field, taking account of cable and NMR coil losses. The results for the average power deposition agree within about 20% for the exact model of the cylinder with axial field, when applied to the exposed torso volume enclosed by the rf coil. The average values predicted by the simple spherical and cylindrical models with axial fields, the exact cylindrical model with transverse field, and the simple truncated cylinder model with transverse field were about two to three times that measured, while the simple model consisting of an infinitely long cylinder with transverse field gave results about six times that measured. The surface power deposition measured by observing the incremental power as a function of external torso radius was comparable to the average value. This is consistent with the presence of a variable thickness peripheral adipose layer which does not substantially increase surface power deposition with increasing torso radius. The absence of highly localized intensity artifacts in 63-MHz body images does not suggest anomalously intense power deposition at localized internal sites, although peak power is difficult to measure.

  10. MR imaging of the prostate at 3 Tesla: comparison of an external phased-array coil to imaging with an endorectal coil at 1.5 Tesla.

    PubMed

    Sosna, Jacob; Pedrosa, Ivan; Dewolf, William C; Mahallati, Houman; Lenkinski, Robert E; Rofsky, Neil M

    2004-08-01

    To qualitatively compare the image quality of torso phased-array 3-Tesla (3T) imaging of the prostate with that of endorectal 1.5-Tesla imaging. Twenty cases of torso phased-array prostate imaging performed at 3-Tesla with FSE T2 weighted images were evaluated by two readers independently for visualization of the posterior border (PB), seminal vesicles (SV), neurovascular bundles (NVB), and image quality rating (IQR). Studies were performed at large fields of view(FOV) (25 cm) (14 cases) (3TL) and smaller FOV (14 cm) (19 cases) (3TS). A comparison was made to 20 consecutive cases of 1.5-T endorectal evaluation performed during the same time period.Results. 3TL produced a significantly better image quality compared with the small FOV for PB (P = .0001), SV (P =.0001), and IQR (P = .0001). There was a marginally significant difference within the NVB category (P = .0535). 3TL produced an image of similar quality to image quality at 1.5 T for PB (P = .3893), SV (P = .8680), NB (P = .2684), and IQR (P = .8599). Prostate image quality at 3T with a torso phased-array coil can be comparable with that of endorectal 1.5-T imaging. These findings suggest that additional options are now available for magnetic resonance imaging of the prostate gland.

  11. Torso sizing ring construction for hard space suit

    NASA Technical Reports Server (NTRS)

    Vykukal, H. C.

    1986-01-01

    A hard suit for use in space or diving applications having an adjustable length torso covering that will fit a large variety of wearers is described. The torso covering comprises an upper section and a lower section which interconnect so that the covering will fit wearers with short torsos. One or more sizing rings may be inserted between the upper and lower sections to accommodate larger torso sizes as required. Since access of the astronaut to the torso covering is preferably through an opening in the back of the upper section (which is closed off by the backpack), the rings slant upward-forward from the lower edge of the opening. The lower edge of the upper covering section has a coupler which slants upward-forward from the lower edge of the back opening. The lower torso section has a similarly slanted coupler which may interfit with the upper section coupler to accommodate the smallest torso size. One or more sizing rings may be inserted between the coupler sections of the upper and lower torso sections to accommodate larger torsos. Each ring has an upper coupler which may interfit with the upper section coupler and a lower coupler which may interfit with the lower section coupler.

  12. In-vivo measurement of relationship between applied current amplitude and current density magnitude from 10 mA to 110 mA.

    PubMed

    DeMonte, Tim P; Wang, Dinghui; Ma, Weijing; Gao, Jia-Hong; Joy, Michael L G

    2009-01-01

    Current density imaging (CDI) is a magnetic resonance imaging (MRI) technique used to quantitatively measure current density vectors throughout the volume of an object/subject placed in the MRI system. Electrical current pulses are applied externally to the object/subject and are synchronized with the MRI sequence. In this work, CDI is used to measure average current density magnitude in the torso region of an in-vivo piglet for applied current pulse amplitudes ranging from 10 mA to 110 mA. The relationship between applied current amplitude and current density magnitude is linear in simple electronic elements such as wires and resistors; however, this relationship may not be linear in living tissue. An understanding of this relationship is useful for research in defibrillation, human electro-muscular incapacitation (e.g. TASER(R)) and other bioelectric stimulation devices. This work will show that the current amplitude to current density magnitude relationship is slightly nonlinear in living tissue in the range of 10 mA to 110 mA.

  13. Quantifying torso deformity in scoliosis

    NASA Astrophysics Data System (ADS)

    Ajemba, Peter O.; Kumar, Anish; Durdle, Nelson G.; Raso, V. James

    2006-03-01

    Scoliosis affects the alignment of the spine and the shape of the torso. Most scoliosis patients and their families are more concerned about the effect of scoliosis on the torso than its effect on the spine. There is a need to develop robust techniques for quantifying torso deformity based on full torso scans. In this paper, deformation indices obtained from orthogonal maps of full torso scans are used to quantify torso deformity in scoliosis. 'Orthogonal maps' are obtained by applying orthogonal transforms to 3D surface maps. (An 'orthogonal transform' maps a cylindrical coordinate system to a Cartesian coordinate system.) The technique was tested on 361 deformed computer models of the human torso and on 22 scans of volunteers (8 normal and 14 scoliosis). Deformation indices from the orthogonal maps correctly classified up to 95% of the volunteers with a specificity of 1.00 and a sensitivity of 0.91. In addition to classifying scoliosis, the system gives a visual representation of the entire torso in one view and is viable for use in a clinical environment for managing scoliosis.

  14. Halo vest instrumentation

    NASA Astrophysics Data System (ADS)

    Huston, Dryver R.; Krag, Martin

    1996-05-01

    The halo vest is a head and neck immobilization system that is often used on patients that are recovering from cervical trauma or surgery. The halo vest system consists of a rigid halo that is firmly attached to the skull, an upright support structure for stabilization and immobilization, and a torso-enveloping vest. The main purpose of this study was to measure the forces that are carried by the halo-vest structure as the subject undergoes various activities of daily living and external loading for different vest designs. A tethered strain gage load cell based instrumentation system was used to take these load measurements on ten different subjects. Three different halo-vest systems were evaluated. The primary difference between the vests was the amount of torso coverage and the use of shoulder straps. The loads were measured, analyzed and used to compare the vests and to create a model of halo-vest-neck mechanics. Future applications of this technology to standalone data logging, pin-load measuring and biofeedback applications are discussed.

  15. Involvement of upper torso stress amplification, tissue compression and distortion in the pathogenesis of keloids.

    PubMed

    Bux, Shamin; Madaree, Anil

    2012-03-01

    Keloids are benign tumours composed of fibrous tissue produced during excessive tissue repair triggered by minor injury, trauma or surgical incision. Although it is recognized that keloids have a propensity to form in the upper torso of the body, the predisposing factors responsible for this have not been investigated. It is crucial that the aetiopathoical factors implicated in keloid formation be established to provide guidelines for well-informed more successful treatment. We compared keloid-prone and keloid-protected skin, identified pertinent morphological differences and explored how inherent structural characteristics and intrinsic factors may promote keloid formation. It was determined that keloid prone areas were covered with high tension skin that had low stretch and a low elastic modulus when compared with skin in keloid protected areas where the skin was lax with a high elastic modulus and low pre-stress level. Factors contributing to elevated internal stress in keloid susceptible skin were the protrusion of hard connective tissue such as bony prominences or cartilage into the dermis of skin as well as inherent skin characteristics such as the bundled arrangement of collagen in the reticular dermis, the existent high tension, the low elastic modulus, low stretch ability, contractile forces exerted by wound healing fibroblastic cells and external forces. Stress promotes keloid formation by causing dermal distortion and compression which subsequently stimulate proliferation and enhanced protein synthesis in wound healing fibroblastic cells. The strain caused by stress also compresses and occludes microvessels causing ischaemic effects and reperfusion injury which stimulate growth when blood rich in growth factors returns to the tissue. The growth promoting effects of increased internal stress, primarily, and growth factors released by reperfusing blood, manifest in keloid formation. Other inherent skin characteristics promoting keloid growth during the late stages of wound healing in the upper torso are the thinner epidermis, the presence of vellus hairs, the absence of protective immunoglobulin A (IgA), and the thick fragile quality of upper torso skin. As it is not known why there is a predilection for keloids to form in the upper torso of the body, this hypothesis implicating and associating inherent morphological characteristics and elevated stress in the aetiopathogenesis of keloids is of potential value in terms of prevention, management and treatment of these enigmatic tumours. Copyright © 2011 Elsevier Ltd. All rights reserved.

  16. Efficacy of side air bags in reducing driver deaths in driver-side collisions.

    PubMed

    Braver, Elisa R; Kyrychenko, Sergey Y

    2004-03-15

    Side air bags, a relatively new technology designed to protect the head and/or torso in side-impact collisions, are becoming increasingly common in automobiles. Their efficacy in preventing US driver deaths among cars struck on the near (driver's) side was examined using data from the Fatality Analysis Reporting System and the General Estimates System. Risk ratios for driver death per nearside collision during 1999-2001 were computed for head/torso and torso-only side air bags in cars from model years 1997-2002, relative to cars without side air bags. Confounding was addressed by adjusting nearside risk ratios for front- and rear-impact mortality, which is unaffected by side air bags. Risk ratios were 0.55 (95% confidence interval: 0.43, 0.71) for head/torso air bags and 0.89 (95% confidence interval: 0.79, 1.01) for torso-only air bags. Risk was reduced when cars with head/torso air bags were struck by cars/minivans (significant) or pickup trucks/sport utility vehicles (nonsignificant). Risk was reduced in two-vehicle collisions and among male drivers and drivers aged 16-64 years. Protective effects associated with torso-only air bags were observed in single-vehicle crashes and among male and 16- to 64-year-old drivers. Head/torso side air bags appear to be very effective in reducing nearside driver deaths, whereas torso-only air bags appear less protective.

  17. 49 CFR 572.145 - Upper and lower torso assemblies and torso flexion test procedure.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... permits the upper half of the torso, as measured at the posterior surface of the torso reference plane shown in Figure P5 of this subpart, to translate in angular motion in the midsagittal plane 45 ±0.5 degrees relative to the vertical transverse plane, at which time the pulling force applied must not be...

  18. Development of new anatomy reconstruction software to localize cardiac isochrones to the cardiac surface from the 12 lead ECG.

    PubMed

    van Dam, Peter M; Gordon, Jeffrey P; Laks, Michael M; Boyle, Noel G

    2015-01-01

    Non-invasive electrocardiographic imaging (ECGI) of the cardiac muscle can help the pre-procedure planning of the ablation of ventricular arrhythmias by reducing the time to localize the origin. Our non-invasive ECGI system, the cardiac isochrone positioning system (CIPS), requires non-intersecting meshes of the heart, lungs and torso. However, software to reconstruct the meshes of the heart, lungs and torso with the capability to check and prevent these intersections is currently lacking. Consequently the reconstruction of a patient specific model with realistic atrial and ventricular wall thickness and incorporating blood cavities, lungs and torso usually requires additional several days of manual work. Therefore new software was developed that checks and prevents any intersections, and thus enables the use of accurate reconstructed anatomical models within CIPS. In this preliminary study we investigated the accuracy of the created patient specific anatomical models from MRI or CT. During the manual segmentation of the MRI data the boundaries of the relevant tissues are determined. The resulting contour lines are used to automatically morph reference meshes of the heart, lungs or torso to match the boundaries of the morphed tissue. Five patients were included in the study; models of the heart, lungs and torso were reconstructed from standard cardiac MRI images. The accuracy was determined by computing the distance between the segmentation contours and the morphed meshes. The average accuracy of the reconstructed cardiac geometry was within 2mm with respect to the manual segmentation contours on the MRI images. Derived wall volumes and left ventricular wall thickness were within the range reported in literature. For each reconstructed heart model the anatomical heart axis was computed using the automatically determined anatomical landmarks of the left apex and the mitral valve. The accuracy of the reconstructed heart models was well within the accuracy of the used medical image data (pixel size <1.5mm). For the lungs and torso the number of triangles in the mesh was reduced, thus decreasing the accuracy of the reconstructed mesh. A novel software tool has been introduced, which is able to reconstruct accurate cardiac anatomical models from MRI or CT within only a few hours. This new anatomical reconstruction tool might reduce the modeling errors within the cardiac isochrone positioning system and thus enable the clinical application of CIPS to localize the PVC/VT focus to the ventricular myocardium from only the standard 12 lead ECG. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. A dual-Kinect approach to determine torso surface motion for respiratory motion correction in PET

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heß, Mirco, E-mail: mirco.hess@uni-muenster.de; Büther, Florian; Dawood, Mohammad

    2015-05-15

    Purpose: Respiratory gating is commonly used to reduce blurring effects and attenuation correction artifacts in positron emission tomography (PET). Established clinically available methods that employ body-attached hardware for acquiring respiration signals rely on the assumption that external surface motion and internal organ motion are well correlated. In this paper, the authors present a markerless method comprising two Microsoft Kinects for determining the motion on the whole torso surface and aim to demonstrate its validity and usefulness—including the potential to study the external/internal correlation and to provide useful information for more advanced correction approaches. Methods: The data of two Kinects aremore » used to calculate 3D representations of a patient’s torso surface with high spatial coverage. Motion signals can be obtained for any position by tracking the mean distance to a virtual camera with a view perpendicular to the surrounding surface. The authors have conducted validation experiments including volunteers and a moving high-precision platform to verify the method’s suitability for providing meaningful data. In addition, the authors employed it during clinical {sup 18}F-FDG-PET scans and exemplarily analyzed the acquired data of ten cancer patients. External signals of abdominal and thoracic regions as well as data-driven signals were used for gating and compared with respect to detected displacement of present lesions. Additionally, the authors quantified signal similarities and time shifts by analyzing cross-correlation sequences. Results: The authors’ results suggest a Kinect depth resolution of approximately 1 mm at 75 cm distance. Accordingly, valid signals could be obtained for surface movements with small amplitudes in the range of only few millimeters. In this small sample of ten patients, the abdominal signals were better suited for gating the PET data than the thoracic signals and the correlation of data-driven signals was found to be stronger with abdominal signals than with thoracic signals (average Pearson correlation coefficients of 0.74 ± 0.17 and 0.45 ± 0.23, respectively). In all cases, except one, the abdominal respiratory motion preceded the thoracic motion—a maximum delay of approximately 600 ms was detected. Conclusions: The method provides motion information with sufficiently high spatial and temporal resolution. Thus, it enables meaningful analysis in the form of comparisons between amplitudes and phase shifts of signals from different regions. In combination with a large field-of-view, as given by combining the data of two Kinect cameras, it yields surface representations that might be useful in the context of motion correction and motion modeling.« less

  20. Understanding 3D human torso shape via manifold clustering

    NASA Astrophysics Data System (ADS)

    Li, Sheng; Li, Peng; Fu, Yun

    2013-05-01

    Discovering the variations in human torso shape plays a key role in many design-oriented applications, such as suit designing. With recent advances in 3D surface imaging technologies, people can obtain 3D human torso data that provide more information than traditional measurements. However, how to find different human shapes from 3D torso data is still an open problem. In this paper, we propose to use spectral clustering approach on torso manifold to address this problem. We first represent high-dimensional torso data in a low-dimensional space using manifold learning algorithm. Then the spectral clustering method is performed to get several disjoint clusters. Experimental results show that the clusters discovered by our approach can describe the discrepancies in both genders and human shapes, and our approach achieves better performance than the compared clustering method.

  1. Characterization and Modeling of Thoraco-Abdominal Response to Blast Waves. Volume 4. Biomechanical Model of Thorax Response to Blast Loading

    DTIC Science & Technology

    1985-05-01

    non- zero Dirichlet boundary conditions and/or general mixed type boundary conditions. Note that Neumann type boundary condi- tion enters the problem by...Background ................................. ................... I 1.3 General Description ..... ............ ........... . ....... ...... 2 2. ANATOMICAL...human and varions loading conditions for the definition of a generalized safety guideline of blast exposure. To model the response of a sheep torso

  2. Difference in dummy responses in matched side impact tests of vehicles with and without side airbags.

    PubMed

    Viano, David C; Parenteau, Chantal S

    2016-07-03

    Insurance Institute for Highway Safety (IIHS) high-hooded side impacts were analyzed for matched vehicle tests with and without side airbags. The comparison provides a measure of the effectiveness of side airbags in reducing biomechanical responses for near-side occupants struck by trucks, SUVs, and vans at 50 km/h. The IIHS moving deformable barrier (MDB) uses a high-hooded barrier face. It weighs 1,500 kg and impacts the driver side perpendicular to the vehicle at 50 km/h. SID IIs dummies are placed in the driver and left second-row seats. They represent fifth percentile female occupants. IIHS tests were reviewed for matches with one test with a side airbag and another without it in 2003-2007 model year (MY) vehicles. Four side airbag systems were evaluated: (1) curtain and torso side airbags, (2) head and torso side airbag, (3) curtain side airbag, and (4) torso side airbag. There were 24 matched IIHS vehicle tests: 13 with and without a curtain and torso side airbags, 4 with and without a head and torso side airbag, 5 with and without a side curtain airbag, and 2 with and without a torso airbag. The head, chest, and pelvis responses were compared for each match and the average difference was determined across all matches for a type of side airbag. The average reduction in head injury criterion (HIC) was 68 ± 16% (P < .001) with curtain and torso side airbags compared to the HIC without side airbags. The average HIC was 296 with curtain and torso side airbags and 1,199 without them. The viscous response (VC) was reduced 54 ± 19% (P < .005) with curtain and torso side airbags. The combined acetabulum and ilium force (7 ± 15%) and pelvic acceleration (-2 ± 17%) were essentially similar in the matched tests. The head and torso side airbag reduced HIC by 42 ± 30% (P < .1) and VC by 32 ± 26% compared to vehicles without a side airbag. The average HIC was 397 with the side head and torso airbag compared to 729 without it. The curtain airbag and torso airbag only showed lower head responses but essentially no difference in the chest and pelvis responses. The curtain and torso side airbags effectively reduced biomechanical responses for the head and chest in 50 km/h side impacts with a high-hooded deformable barrier. The reductions in the IIHS tests are directionally the same as estimated fatality reductions in field crashes reported by NHTSA for side airbags.

  3. 49 CFR 572.175 - Upper and lower torso assemblies and torso flexion test procedure.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    .../lower torso assembly is as follows: (1) Torque the lumbar cable (drawing 420-4130) (incorporated by... threaded attachment holes. Tighten the mountings so that the test material is rigidly affixed to the test...

  4. 49 CFR 572.175 - Upper and lower torso assemblies and torso flexion test procedure.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    .../lower torso assembly is as follows: (1) Torque the lumbar cable (drawing 420-4130) (incorporated by... threaded attachment holes. Tighten the mountings so that the test material is rigidly affixed to the test...

  5. 49 CFR 572.175 - Upper and lower torso assemblies and torso flexion test procedure.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    .../lower torso assembly is as follows: (1) Torque the lumbar cable (drawing 420-4130) (incorporated by... threaded attachment holes. Tighten the mountings so that the test material is rigidly affixed to the test...

  6. LARM PKM solutions for torso design in humanoid robots

    NASA Astrophysics Data System (ADS)

    Ceccarelli, Marco

    2014-12-01

    Human-like torso features are essential in humanoid robots. In this paper problems for design and operation of solutions for a robotic torso are discussed by referring to experiences and designs that have been developed at Laboratory of Robotics and Mechatronics (LARM) in Cassino, Italy. A new solution is presented with conceptual views as waist-trunk structure that makes a proper partition of the performance for walking and arm operations as sustained by a torso.

  7. Effect of torso flexion on the lumbar torso extensor muscle sagittal plane moment arms.

    PubMed

    Jorgensen, Michael J; Marras, William S; Gupta, Purnendu; Waters, Thomas R

    2003-01-01

    Accurate anatomical inputs for biomechanical models are necessary for valid estimates of internal loading. The magnitude of the moment arm of the lumbar erector muscle group is known to vary as a function of such variables as gender. Anatomical evidence indicates that the moment arms decrease during torso flexion. However, moment arm estimates in biomechanical models that account for individual variability have been derived from imaging studies from supine postures. Quantify the sagittal plane moment arms of the lumbar erector muscle group as a function of torso flexion, and identify individual characteristics that are associated with the magnitude of the moment arms as a function of torso flexion. Utilization of a 0.3 Tesla Open magnetic resonance image (MRI) to image and quantify the moment arm of the right erector muscle group as a function of gender and torso flexion. Axial MRI images through and parallel to each of the lumbar intervertebral discs at four torso flexion angles were obtained from 12 male and 12 female subjects in a lateral recumbent posture. Multivariate analysis of variance was used to investigate the differences in the moment arms at different torso flexion angles, whereas hierarchical linear regression was used to investigate associations with individual anthropometric characteristics and spinal posture. The largest decrease in the lumbar erector muscle group moment arm from neutral to 45-degree flexion occurred at the L5-S1 level (9.7% and 8.9% for men and women, respectively). Measures of spinal curvature (L1-S1 lordosis), body mass and trunk characteristics (depth or circumference) were associated with the varying moment arm at most lumbar levels. The sagittal plane moment arms of the lumbar erector muscle mass decrease as the torso flexes forward. The change in moment arms as a function of torso flexion may have an impact on prediction of spinal loading in biomechanical models.

  8. Australian DefenceScience. Volume 15, Number 2, Winter

    DTIC Science & Technology

    2007-01-01

    sources, including the original builders, Vickers Shipyards, the Royal Australian Navy Archives, the Australian National Archives, the British...South Australia. The trial team also included personnel from the Army 3rd/9th Light Horse as well the Royal Melbourne Institute of Technology and Vision...the Austeyr and AK47 weapons. The two torsos presented for testing were made of a 20% strength solution of gelatine jelly , which, at a temperature of

  9. The effect of patient migration in bed on torso elevation.

    PubMed

    Wiggermann, Neal; Kotowski, Susan; Davis, Kermit; VanGilder, Catherine

    2015-01-01

    Elevating the hospital head of bed (HOB) to at least 30° is recommended practice to reduce the risk of ventilator-associated pneumonia (VAP) in mechanically ventilated patients. However, this common practice prescribes the position of the bed and not of the patient, which could be significantly different. The aim of this research was to determine the relationship between patient migration in bed and anatomic torso angle. Ten healthy participants were positioned in a hospital bed that was raised from flat to 30° and 45° HOB elevations. Prior to bed movement, participants were aligned to different locations along the length of the bed to represent different amounts of migration. A motion capture system was used to measure torso angle and migration toward the foot of the bed. The relationship between torso angle and migration was estimated by linear regression. Patient migration resulted in lower torso angles for both 30° and 45° HOB articulations. A migration of 10 cm resulted in a loss of 9.1° and 13.0° of torso angle for HOB articulations of 30° and 45°, respectively (for 30° articulations: (Equation is included in full-text article.)= -0.91, R = .96; for 45° articulations: (Equation is included in full-text article.)= -1.30, R = .98). Migration toward the foot of the bed flattens the torso. To maintain a torso angle that is likely to protect against VAP, healthcare providers need to manage both HOB angle and migration. Protocols and equipment that minimize patient migration will help support effective clinical practice. Future research on patient migration, as it relates to VAP or other outcomes, should measure patient torso angle to allow accurate translation of the results to care practice.

  10. Automatic anatomy partitioning of the torso region on CT images by using multiple organ localizations with a group-wise calibration technique

    NASA Astrophysics Data System (ADS)

    Zhou, Xiangrong; Morita, Syoichi; Zhou, Xinxin; Chen, Huayue; Hara, Takeshi; Yokoyama, Ryujiro; Kanematsu, Masayuki; Hoshi, Hiroaki; Fujita, Hiroshi

    2015-03-01

    This paper describes an automatic approach for anatomy partitioning on three-dimensional (3D) computedtomography (CT) images that divide the human torso into several volume-of-interesting (VOI) images based on anatomical definition. The proposed approach combines several individual detections of organ-location with a groupwise organ-location calibration and correction to achieve an automatic and robust multiple-organ localization task. The essence of the proposed method is to jointly detect the 3D minimum bounding box for each type of organ shown on CT images based on intra-organ-image-textures and inter-organ-spatial-relationship in the anatomy. Machine-learning-based template matching and generalized Hough transform-based point-distribution estimation are used in the detection and calibration processes. We apply this approach to the automatic partitioning of a torso region on CT images, which are divided into 35 VOIs presenting major organ regions and tissues required by routine diagnosis in clinical medicine. A database containing 4,300 patient cases of high-resolution 3D torso CT images is used for training and performance evaluations. We confirmed that the proposed method was successful in target organ localization on more than 95% of CT cases. Only two organs (gallbladder and pancreas) showed a lower success rate: 71 and 78% respectively. In addition, we applied this approach to another database that included 287 patient cases of whole-body CT images scanned for positron emission tomography (PET) studies and used for additional performance evaluation. The experimental results showed that no significant difference between the anatomy partitioning results from those two databases except regarding the spleen. All experimental results showed that the proposed approach was efficient and useful in accomplishing localization tasks for major organs and tissues on CT images scanned using different protocols.

  11. Biotechnology

    NASA Image and Video Library

    2003-02-09

    The Phantom Torso is a tissue-muscle plastic anatomical model of a torso and head. It contains over 350 radiation measuring devices to calculate the radiation that penetrates internal organs in space travel. The Phantom Torso is one of three radiation experiments in Expedition Two including the Borner Ball Neutron Detector and Dosimetric Mapping.

  12. Deformable torso phantoms of Chinese adults for personalized anatomy modelling.

    PubMed

    Wang, Hongkai; Sun, Xiaobang; Wu, Tongning; Li, Congsheng; Chen, Zhonghua; Liao, Meiying; Li, Mengci; Yan, Wen; Huang, Hui; Yang, Jia; Tan, Ziyu; Hui, Libo; Liu, Yue; Pan, Hang; Qu, Yue; Chen, Zhaofeng; Tan, Liwen; Yu, Lijuan; Shi, Hongcheng; Huo, Li; Zhang, Yanjun; Tang, Xin; Zhang, Shaoxiang; Liu, Changjian

    2018-04-16

    In recent years, there has been increasing demand for personalized anatomy modelling for medical and industrial applications, such as ergonomics device development, clinical radiological exposure simulation, biomechanics analysis, and 3D animation character design. In this study, we constructed deformable torso phantoms that can be deformed to match the personal anatomy of Chinese male and female adults. The phantoms were created based on a training set of 79 trunk computed tomography (CT) images (41 males and 38 females) from normal Chinese subjects. Major torso organs were segmented from the CT images, and the statistical shape model (SSM) approach was used to learn the inter-subject anatomical variations. To match the personal anatomy, the phantoms were registered to individual body surface scans or medical images using the active shape model method. The constructed SSM demonstrated anatomical variations in body height, fat quantity, respiratory status, organ geometry, male muscle size, and female breast size. The masses of the deformed phantom organs were consistent with Chinese population organ mass ranges. To validate the performance of personal anatomy modelling, the phantoms were registered to the body surface scan and CT images. The registration accuracy measured from 22 test CT images showed a median Dice coefficient over 0.85, a median volume recovery coefficient (RC vlm ) between 0.85 and 1.1, and a median averaged surface distance (ASD) < 1.5 mm. We hope these phantoms can serve as computational tools for personalized anatomy modelling for the research community. © 2018 Anatomical Society.

  13. Placement of implantable cardioverter-defibrillators in paediatric and congenital heart defect patients: a pipeline for model generation and simulation prediction of optimal configurations

    PubMed Central

    Rantner, Lukas J; Vadakkumpadan, Fijoy; Spevak, Philip J; Crosson, Jane E; Trayanova, Natalia A

    2013-01-01

    There is currently no reliable way of predicting the optimal implantable cardioverter-defibrillator (ICD) placement in paediatric and congenital heart defect (CHD) patients. This study aimed to: (1) develop a new image processing pipeline for constructing patient-specific heart–torso models from clinical magnetic resonance images (MRIs); (2) use the pipeline to determine the optimal ICD configuration in a paediatric tricuspid valve atresia patient; (3) establish whether the widely used criterion of shock-induced extracellular potential (Φe) gradients ≥5 V cm−1 in ≥95% of ventricular volume predicts defibrillation success. A biophysically detailed heart–torso model was generated from patient MRIs. Because transvenous access was impossible, three subcutaneous and three epicardial lead placement sites were identified along with five ICD scan locations. Ventricular fibrillation was induced, and defibrillation shocks were applied from 11 ICD configurations to determine defibrillation thresholds (DFTs). Two configurations with epicardial leads resulted in the lowest DFTs overall and were thus considered optimal. Three configurations shared the lowest DFT among subcutaneous lead ICDs. The Φe gradient criterion was an inadequate predictor of defibrillation success, as defibrillation failed in numerous instances even when 100% of the myocardium experienced such gradients. In conclusion, we have developed a new image processing pipeline and applied it to a CHD patient to construct the first active heart–torso model from clinical MRIs. PMID:23798492

  14. Animal exposure during burn tests

    NASA Technical Reports Server (NTRS)

    Gaume, J. G.

    1976-01-01

    An animal exposure test system has been designed and fabricated for the purpose of collecting physiological and environmental (temperature) data from animal subjects exposed to combustion gases in large scale fire tests. The AETS consists of an open wire mesh, two-compartment cage, one containing an exercise wheel for small rodents, and the other containing one rat instrumented externally for electrocardiogram and respiration. The ECG and respiration sensors are located in a belt placed around the torso of the subject, electrode wires forming an umbilical to a connector in the top of the compartment. A cable extends from the connector to the power supply and signal conditioning electronics. These are connected to a dual-beam oscilloscope for real time monitoring and a magnetic tape recorder having three or more channels. Endpoints observed are bradycardia, cardiac arrhythmias, changes in respiratory pattern, respiratory arrest and cardiac arrest. The ECG record also appears to be a good method of monitoring animal activity as indicated by an increase in EMG noise superimposed on the record during increased activity of the torso musculature. Examples of the recordings are presented and discussed as to their significance regarding toxicity of fire gases.

  15. Characterization of optical-surface-imaging-based spirometry for respiratory surrogating in radiotherapy

    PubMed Central

    Li, Guang; Huang, Hailiang; Chen, Qing; Gaebler, Carl P.; Lin, Tiffany; Yuan, Amy; Rimner, Andreas; Mechalakos, James

    2016-01-01

    Purpose: To provide a comprehensive characterization of a novel respiratory surrogate that uses optical surface imaging (OSI) for accurate tidal volume (TV) measurement, dynamic airflow (TV′) calculation, and quantitative breathing pattern (BP) estimation during free breathing (FB), belly breathing (BB), chest breathing (CB), and breath hold (BH). Methods: Optical surface imaging, which captures all respiration-induced torso surface motion, was applied to measure respiratory TV, TV′, and BP in three common breathing patterns. Eleven healthy volunteers participated in breathing experiments with concurrent OSI-based and conventional spirometric measurements under an institutional review board approved protocol. This OSI-based technique measures dynamic TV from torso volume change (ΔVtorso = TV) in reference to full exhalation and airflow (TV′ = dTV/dt). Volume conservation, excluding exchanging air, was applied for OSI-based measurements under negligible pleural pressure variation in FB, BB, and CB. To demonstrate volume conservation, a constant TV was measured during BH while the chest and belly are moving (“pretended” respiration). To assess the accuracy of OSI-based spirometry, a conventional spirometer was used as the standard for both TV and TV′. Using OSI, BP was measured as BPOSI = ΔVchest/ΔVtorso and BP can be visualized using BPSHI = SHIchest/(SHIchest + SHIbelly), where surface height index (SHI) is defined as the mean vertical distance within a region of interest on the torso surface. A software tool was developed for OSI image processing, volume calculation, and BP visualization, and another tool was implemented for data acquisition using a Bernoulli-type spirometer. Results: The accuracy of the OSI-based spirometry is −21 ± 33 cm3 or −3.5% ± 6.3% averaged from 11 volunteers with 76 ± 28 breathing cycles on average in FB. Breathing variations between two separate acquisitions with approximate 30-min intervals are substantial: −1% ± 34% (ranging from −64% to 40%) in TV, 4% ± 20% (ranging from −50% to 26%) in breathing period (T), and −1% ± 34% (ranging from −49% to 44%) in BP. The airflow accuracy and variation (between two exercises) are −1 ± 54 cm3/s and −5% ± 30%, respectively. The slope of linear regression between OSI–TV and spirometric TV is 0.93 (R2 = 0.95) for FB, 0.96 (R2 = 0.98) for BB, and 0.95 (R2 = 0.95) for CB. The correlation between the two spirometric measurements is 0.98 ± 0.01. BP increases from BB, FB to CB, while TV increases from FB, BB, to CB. Under BH, 4% volume variation (range) on average was observed. Conclusions: The OSI-based technique provides an accurate measurement of tidal volume, airflow rate, and breathing pattern; all affect internal organ motion. This technique can be applied to various breathing patterns, including FB, BB, and CB. Substantial breathing irregularities and irreproducibility were observed and quantified with the OSI-based technique. These breathing parameters are useful to quantify breathing conditions, which could be used for effective tumor motion predictions. PMID:26936719

  16. 49 CFR 572.125 - Upper and lower torso assemblies and torso flexion test procedure.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... of the dummy, the pull cable, and the load cell as shown in Figure N5. (7) Apply a tension force in the midsagittal plane to the pull cable as shown in Figure N5 at any upper torso deflection rate... determine the stiffness effects of the lumbar spine (drawing 127-3002), including cable (drawing 127-8095...

  17. Respiratory effort energy estimation using Doppler radar.

    PubMed

    Shahhaidar, Ehsaneh; Yavari, Ehsan; Young, Jared; Boric-Lubecke, Olga; Stickley, Cris

    2012-01-01

    Human respiratory effort can be harvested to power wearable biosensors and mobile electronic devices. The very first step toward designing a harvester is to estimate available energy and power. This paper describes an estimation of the available power and energy due to the movements of the torso during breathing, using Doppler radar by detecting breathing rate, torso displacement, torso movement velocity and acceleration along the sagittal movement of the torso. The accuracy of the detected variables is verified by two reference methods. The experimental result obtained from a healthy female human subject shows that the available power from circumferential movement can be higher than the power from the sagittal movement.

  18. STS-57 MS2 Sherlock dons EMU upper torso with technicians' help at JSC's WETF

    NASA Technical Reports Server (NTRS)

    1992-01-01

    STS-57 Mission Specialist 2 (MS2) Nancy J. Sherlock, wearing the liquid cooling and ventilation garment (LCVG) and an extravehicular mobility unit (EMU) lower torso, squats under the EMU upper torso and prepares to raise her arms into the sleeves. Technicians stand on either side of Sherlock and are ready to assist her in donning the upper torso. When fully suited the platform Sherlock is on will be lowered into the 25 foot deep pool located in JSC's Weightless Environment Training Facility (WETF) Bldg 29. During the underwater simulation, Sherlock will practice extravehicular activity (EVA) procedures.

  19. Automated scoring system of standard uptake value for torso FDG-PET images

    NASA Astrophysics Data System (ADS)

    Hara, Takeshi; Kobayashi, Tatsunori; Kawai, Kazunao; Zhou, Xiangrong; Itoh, Satoshi; Katafuchi, Tetsuro; Fujita, Hiroshi

    2008-03-01

    The purpose of this work was to develop an automated method to calculate the score of SUV for torso region on FDG-PET scans. The three dimensional distributions for the mean and the standard deviation values of SUV were stored in each volume to score the SUV in corresponding pixel position within unknown scans. The modeling methods is based on SPM approach using correction technique of Euler characteristic and Resel (Resolution element). We employed 197 nor-mal cases (male: 143, female: 54) to assemble the normal metabolism distribution of FDG. The physique were registered each other in a rectangular parallelepiped shape using affine transformation and Thin-Plate-Spline technique. The regions of the three organs were determined based on semi-automated procedure. Seventy-three abnormal spots were used to estimate the effectiveness of the scoring methods. As a result, the score images correctly represented that the scores for normal cases were between zeros to plus/minus 2 SD. Most of the scores of abnormal spots associated with cancer were lager than the upper of the SUV interval of normal organs.

  20. Optimal cycling time trial position models: aerodynamics versus power output and metabolic energy.

    PubMed

    Fintelman, D M; Sterling, M; Hemida, H; Li, F-X

    2014-06-03

    The aerodynamic drag of a cyclist in time trial (TT) position is strongly influenced by the torso angle. While decreasing the torso angle reduces the drag, it limits the physiological functioning of the cyclist. Therefore the aims of this study were to predict the optimal TT cycling position as function of the cycling speed and to determine at which speed the aerodynamic power losses start to dominate. Two models were developed to determine the optimal torso angle: a 'Metabolic Energy Model' and a 'Power Output Model'. The Metabolic Energy Model minimised the required cycling energy expenditure, while the Power Output Model maximised the cyclists׳ power output. The input parameters were experimentally collected from 19 TT cyclists at different torso angle positions (0-24°). The results showed that for both models, the optimal torso angle depends strongly on the cycling speed, with decreasing torso angles at increasing speeds. The aerodynamic losses outweigh the power losses at cycling speeds above 46km/h. However, a fully horizontal torso is not optimal. For speeds below 30km/h, it is beneficial to ride in a more upright TT position. The two model outputs were not completely similar, due to the different model approaches. The Metabolic Energy Model could be applied for endurance events, while the Power Output Model is more suitable in sprinting or in variable conditions (wind, undulating course, etc.). It is suggested that despite some limitations, the models give valuable information about improving the cycling performance by optimising the TT cycling position. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Simulation of a steady-state integrated human thermal system.

    NASA Technical Reports Server (NTRS)

    Hsu, F. T.; Fan, L. T.; Hwang, C. L.

    1972-01-01

    The mathematical model of an integrated human thermal system is formulated. The system consists of an external thermal regulation device on the human body. The purpose of the device (a network of cooling tubes held in contact with the surface of the skin) is to maintain the human body in a state of thermoneutrality. The device is controlled by varying the inlet coolant temperature and coolant mass flow rate. The differential equations of the model are approximated by a set of algebraic equations which result from the application of the explicit forward finite difference method to the differential equations. The integrated human thermal system is simulated for a variety of combinations of the inlet coolant temperature, coolant mass flow rate, and metabolic rates. Two specific cases are considered: (1) the external thermal regulation device is placed only on the head and (2) the devices are placed on the head and the torso. The results of the simulation indicate that when the human body is exposed to hot environment, thermoneutrality can be attained by localized cooling if the operating variables of the external regulation device(s) are properly controlled.

  2. Impact of Prehospital Medical Evacuation (MEDEVAC) Transport Time on Combat Mortality in Patients with Non-Compressible Torso Injury and Traumatic Amputations

    DTIC Science & Technology

    2018-12-28

    MED EV AC) transport time on combat mortality in patients with non-compressible torso injury and traumatic amputations Sb. GRANT NUMBER Sc. PROGRAM...increased morbidity and mortality. Limited data exists on the influence of transport time on patient outcomes with specific injury types. The...treatment facility on morbidity and mortality in casualties with traumatic extremity amputation and non-compressible torso injury (NCTI). Methods: We

  3. Real-time 3D visualization of the thoraco-abdominal surface during breathing with body movement and deformation extraction.

    PubMed

    Povšič, K; Jezeršek, M; Možina, J

    2015-07-01

    Real-time 3D visualization of the breathing displacements can be a useful diagnostic tool in order to immediately observe the most active regions on the thoraco-abdominal surface. The developed method is capable of separating non-relevant torso movement and deformations from the deformations that are solely related to breathing. This makes it possible to visualize only the breathing displacements. The system is based on the structured laser triangulation principle, with simultaneous spatial and color data acquisition of the thoraco-abdominal region. Based on the tracking of the attached passive markers, the torso movement and deformation is compensated using rigid and non-rigid transformation models on the three-dimensional (3D) data. The total time of 3D data processing together with visualization equals 20 ms per cycle.In vitro verification of the rigid movement extraction was performed using the iterative closest point algorithm as a reference. Furthermore, a volumetric evaluation on a live subject was performed to establish the accuracy of the rigid and non-rigid model. The root mean square deviation between the measured and the reference volumes shows an error of  ±0.08 dm(3) for rigid movement extraction. Similarly, the error was calculated to be  ±0.02 dm(3) for torsional deformation extraction and  ±0.11 dm(3) for lateral bending deformation extraction. The results confirm that during the torso movement and deformation, the proposed method is sufficiently accurate to visualize only the displacements related to breathing. The method can be used, for example, during the breathing exercise on an indoor bicycle or a treadmill.

  4. Defying geometric similarity: Shape centralization in male UK offshore workers.

    PubMed

    Stewart, Arthur D; Ledingham, Robert J; Furnace, Graham; Williams, Hector; Nevill, Alan M

    2017-05-06

    Applying geometric similarity predictions of body dimensions to specific occupational groups has the potential to reveal useful ergonomic and health implications. This study assessed a representative sample of the male UK offshore workforce, and examined how body dimensions from sites typifying musculoskeletal development or fat accumulation, differed from predicted values. A cross sectional sample was obtained across seven weight categories using quota sampling, to match the wider workforce. In total, 588 UK offshore workers, 84 from each of seven weight categories, were measured for stature, mass and underwent 3D body scans which yielded 22 dimensional measurements. Each measurement was modeled using a body-mass power law (adjusting for age), to derive its exponent, which was compared against that predicted from geometric similarity. Mass scaled to stature 1.73 (CI: 1.44-2.02). Arm and leg volume increased by mass 0.8 , and torso volume increased by mass 1.1 in contrast to mass 1.0 predicted by geometric similarity. Neck girth increased by mass 0.33 as expected, while torso girth and depth dimensions increased by mass 0.53-0.72 , all substantially greater than assumed by geometric similarity. After controlling for age, offshore workers experience spectacular "super-centralization" of body shape, with greatest gains in abdominal depth and girth dimensions in areas of fat accumulation, and relative dimensional loss in limbs. These findings are consistent with the antecedents of sarcopenic obesity, and should be flagged as a health concern for this workforce, and for future targeted research and lifestyle interventions. © 2016 Wiley Periodicals, Inc.

  5. Optimal Magnetic Sensor Vests for Cardiac Source Imaging

    PubMed Central

    Lau, Stephan; Petković, Bojana; Haueisen, Jens

    2016-01-01

    Magnetocardiography (MCG) non-invasively provides functional information about the heart. New room-temperature magnetic field sensors, specifically magnetoresistive and optically pumped magnetometers, have reached sensitivities in the ultra-low range of cardiac fields while allowing for free placement around the human torso. Our aim is to optimize positions and orientations of such magnetic sensors in a vest-like arrangement for robust reconstruction of the electric current distributions in the heart. We optimized a set of 32 sensors on the surface of a torso model with respect to a 13-dipole cardiac source model under noise-free conditions. The reconstruction robustness was estimated by the condition of the lead field matrix. Optimization improved the condition of the lead field matrix by approximately two orders of magnitude compared to a regular array at the front of the torso. Optimized setups exhibited distributions of sensors over the whole torso with denser sampling above the heart at the front and back of the torso. Sensors close to the heart were arranged predominantly tangential to the body surface. The optimized sensor setup could facilitate the definition of a standard for sensor placement in MCG and the development of a wearable MCG vest for clinical diagnostics. PMID:27231910

  6. Automated segmentations of skin, soft-tissue, and skeleton, from torso CT images

    NASA Astrophysics Data System (ADS)

    Zhou, Xiangrong; Hara, Takeshi; Fujita, Hiroshi; Yokoyama, Ryujiro; Kiryu, Takuji; Hoshi, Hiroaki

    2004-05-01

    We have been developing a computer-aided diagnosis (CAD) scheme for automatically recognizing human tissue and organ regions from high-resolution torso CT images. We show some initial results for extracting skin, soft-tissue and skeleton regions. 139 patient cases of torso CT images (male 92, female 47; age: 12-88) were used in this study. Each case was imaged with a common protocol (120kV/320mA) and covered the whole torso with isotopic spatial resolution of about 0.63 mm and density resolution of 12 bits. A gray-level thresholding based procedure was applied to separate the human body from background. The density and distance features to body surface were used to determine the skin, and separate soft-tissue from the others. A 3-D region growing based method was used to extract the skeleton. We applied this system to the 139 cases and found that the skin, soft-tissue and skeleton regions were recognized correctly for 93% of the patient cases. The accuracy of segmentation results was acceptable by evaluating the results slice by slice. This scheme will be included in CAD systems for detecting and diagnosing the abnormal lesions in multi-slice torso CT images.

  7. Development of the Cellular Immune System of Drosophila Requires the Membrane Attack Complex/Perforin-Like Protein Torso-Like.

    PubMed

    Forbes-Beadle, Lauren; Crossman, Tova; Johnson, Travis K; Burke, Richard; Warr, Coral G; Whisstock, James C

    2016-10-01

    Pore-forming members of the membrane attack complex/perforin-like (MACPF) protein superfamily perform well-characterized roles as mammalian immune effectors. For example, complement component 9 and perforin function to directly form pores in the membrane of Gram-negative pathogens or virally infected/transformed cells, respectively. In contrast, the only known MACPF protein in Drosophila melanogaster, Torso-like, plays crucial roles during development in embryo patterning and larval growth. Here, we report that in addition to these functions, Torso-like plays an important role in Drosophila immunity. However, in contrast to a hypothesized effector function in, for example, elimination of Gram-negative pathogens, we find that torso-like null mutants instead show increased susceptibility to certain Gram-positive pathogens such as Staphylococcus aureus and Enterococcus faecalis We further show that this deficit is due to a severely reduced number of circulating immune cells and, as a consequence, an impaired ability to phagocytose bacterial particles. Together these data suggest that Torso-like plays an important role in controlling the development of the Drosophila cellular immune system. Copyright © 2016 by the Genetics Society of America.

  8. Improved dose-volume histogram estimates for radiopharmaceutical therapy by optimizing quantitative SPECT reconstruction parameters

    NASA Astrophysics Data System (ADS)

    Cheng, Lishui; Hobbs, Robert F.; Segars, Paul W.; Sgouros, George; Frey, Eric C.

    2013-06-01

    In radiopharmaceutical therapy, an understanding of the dose distribution in normal and target tissues is important for optimizing treatment. Three-dimensional (3D) dosimetry takes into account patient anatomy and the nonuniform uptake of radiopharmaceuticals in tissues. Dose-volume histograms (DVHs) provide a useful summary representation of the 3D dose distribution and have been widely used for external beam treatment planning. Reliable 3D dosimetry requires an accurate 3D radioactivity distribution as the input. However, activity distribution estimates from SPECT are corrupted by noise and partial volume effects (PVEs). In this work, we systematically investigated OS-EM based quantitative SPECT (QSPECT) image reconstruction in terms of its effect on DVHs estimates. A modified 3D NURBS-based Cardiac-Torso (NCAT) phantom that incorporated a non-uniform kidney model and clinically realistic organ activities and biokinetics was used. Projections were generated using a Monte Carlo (MC) simulation; noise effects were studied using 50 noise realizations with clinical count levels. Activity images were reconstructed using QSPECT with compensation for attenuation, scatter and collimator-detector response (CDR). Dose rate distributions were estimated by convolution of the activity image with a voxel S kernel. Cumulative DVHs were calculated from the phantom and QSPECT images and compared both qualitatively and quantitatively. We found that noise, PVEs, and ringing artifacts due to CDR compensation all degraded histogram estimates. Low-pass filtering and early termination of the iterative process were needed to reduce the effects of noise and ringing artifacts on DVHs, but resulted in increased degradations due to PVEs. Large objects with few features, such as the liver, had more accurate histogram estimates and required fewer iterations and more smoothing for optimal results. Smaller objects with fine details, such as the kidneys, required more iterations and less smoothing at early time points post-radiopharmaceutical administration but more smoothing and fewer iterations at later time points when the total organ activity was lower. The results of this study demonstrate the importance of using optimal reconstruction and regularization parameters. Optimal results were obtained with different parameters at each time point, but using a single set of parameters for all time points produced near-optimal dose-volume histograms.

  9. Effect of head motion on MRI B0 field distribution.

    PubMed

    Liu, Jiaen; de Zwart, Jacco A; van Gelderen, Peter; Murphy-Boesch, Joseph; Duyn, Jeff H

    2018-05-16

    To identify and characterize the sources of B 0 field changes due to head motion, to reduce motion sensitivity in human brain MRI. B 0 fields were measured in 5 healthy human volunteers at various head poses. After measurement of the total field, the field originating from the subject was calculated by subtracting the external field generated by the magnet and shims. A subject-specific susceptibility model was created to quantify the contribution of the head and torso. The spatial complexity of the field changes was analyzed using spherical harmonic expansion. Minor head pose changes can cause substantial and spatially complex field changes in the brain. For rotations and translations of approximately 5 º and 5 mm, respectively, at 7 T, the field change that is associated with the subject's magnetization generates a standard deviation (SD) of about 10 Hz over the brain. The stationary torso contributes to this subject-associated field change significantly with a SD of about 5 Hz. The subject-associated change leads to image-corrupting phase errors in multi-shot T2*-weighted acquisitions. The B 0 field changes arising from head motion are problematic for multishot T2*-weighted imaging. Characterization of the underlying sources provides new insights into mitigation strategies, which may benefit from individualized predictive field models in addition to real-time field monitoring and correction strategies. © 2018 International Society for Magnetic Resonance in Medicine.

  10. Pressure-constrained, reduced-DOF, interconnected parallel manipulators with applications to space suit design

    NASA Astrophysics Data System (ADS)

    Jacobs, Shane Earl

    This dissertation presents the concept of a Morphing Upper Torso, an innovative pressure suit design that incorporates robotic elements to enable a resizable, highly mobile and easy to don/doff spacesuit. The torso is modeled as a system of interconnected, pressure-constrained, reduced-DOF, wire-actuated parallel manipulators, that enable the dimensions of the suit to be reconfigured to match the wearer. The kinematics, dynamics and control of wire-actuated manipulators are derived and simulated, along with the Jacobian transforms, which relate the total twist vector of the system to the vector of actuator velocities. Tools are developed that allow calculation of the workspace for both single and interconnected reduced-DOF robots of this type, using knowledge of the link lengths. The forward kinematics and statics equations are combined and solved to produce the pose of the platforms along with the link tensions. These tools allow analysis of the full Morphing Upper Torso design, in which the back hatch of a rear-entry torso is interconnected with the waist ring, helmet ring and two scye bearings. Half-scale and full-scale experimental models are used along with analytical models to examine the feasibility of this novel space suit concept. The analytical and experimental results demonstrate that the torso could be expanded to facilitate donning and doffng, and then contracted to match different wearer's body dimensions. Using the system of interconnected parallel manipulators, suit components can be accurately repositioned to different desired configurations. The demonstrated feasibility of the Morphing Upper Torso concept makes it an exciting candidate for inclusion in a future planetary suit architecture.

  11. Wound Ballistics Modeling for Blast Loading Blunt Force Impact and Projectile Penetration.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taylor, Paul A.

    Light body armor development for the warfighter is based on trial-and-error testing of prototype designs against ballistic projectiles. Torso armor testing against blast is nonexistent but necessary to protect the heart and lungs. In tests against ballistic projectiles, protective apparel is placed over ballistic clay and the projectiles are fired into the armor/clay target. The clay represents the human torso and its behind-armor, permanent deflection is the principal metric used to assess armor protection. Although this approach provides relative merit assessment of protection, it does not examine the behind-armor blunt trauma to crucial torso organs. We propose a modeling andmore » simulation (M&S) capability for wound injury scenarios to the head, neck, and torso of the warfighter. We will use this toolset to investigate the consequences of, and mitigation against, blast exposure, blunt force impact, and ballistic projectile penetration leading to damage of critical organs comprising the central nervous, cardiovascular, and respiratory systems. We will leverage Sandia codes and our M&S expertise on traumatic brain injury to develop virtual anatomical models of the head, neck, and torso and the simulation methodology to capture the physics of wound mechanics. Specifically, we will investigate virtual wound injuries to the head, neck, and torso without and with protective armor to demonstrate the advantages of performing injury simulations for the development of body armor. The proposed toolset constitutes a significant advance over current methods by providing a virtual simulation capability to investigate wound injury and optimize armor design without the need for extensive field testing.« less

  12. Computer simulation comparison of tripolar, bipolar, and spline Laplacian electrocadiogram estimators.

    PubMed

    Chen, T; Besio, W; Dai, W

    2009-01-01

    A comparison of the performance of the tripolar and bipolar concentric as well as spline Laplacian electrocardiograms (LECGs) and body surface Laplacian mappings (BSLMs) for localizing and imaging the cardiac electrical activation has been investigated based on computer simulation. In the simulation a simplified eccentric heart-torso sphere-cylinder homogeneous volume conductor model were developed. Multiple dipoles with different orientations were used to simulate the underlying cardiac electrical activities. Results show that the tripolar concentric ring electrodes produce the most accurate LECG and BSLM estimation among the three estimators with the best performance in spatial resolution.

  13. Acceptance tests of various upper torso restraints.

    DOT National Transportation Integrated Search

    1971-03-01

    The study demonstrates that people can be motivated to utilize and, in fact, eagerly accept the use of upper torso restraint equipment for the prevention of head and chest injuries induced by flailing during crash decelerations, provided that specifi...

  14. Pilot Fullerton dons EES anti-gravity suit lower torso on middeck

    NASA Technical Reports Server (NTRS)

    1982-01-01

    Pilot Fullerton dons ejection escape suit (EES) anti-gravity (anti-g) suit lower torso on forward port side middeck above potable water tank. Anti-g suit is an olive drab inner garment that complements EES.

  15. Human torso phantom for imaging of heart with realistic modes of cardiac and respiratory motion

    DOEpatents

    Boutchko, Rostyslav; Balakrishnan, Karthikayan; Gullberg, Grant T; O& #x27; Neil, James P

    2013-09-17

    A human torso phantom and its construction, wherein the phantom mimics respiratory and cardiac cycles in a human allowing acquisition of medical imaging data under conditions simulating patient cardiac and respiratory motion.

  16. Spacesuit Soft Upper Torso Sizing Systems

    NASA Technical Reports Server (NTRS)

    Graziosi, David; Splawn, Keith

    2011-01-01

    The passive sizing system consists of a series of low-profile pulleys attached to the front and back of the shoulder bearings on a spacesuit soft upper torso (SUT), textile cord or stainless steel cable, and a modified commercial ratchet mechanism. The cord/cable is routed through the pulleys and attached to the ratchet mechanism mounted on the front of the spacesuit within reach of the suited subject. Upon actuating the ratchet mechanism, the shoulder bearing breadth is changed, providing variable upper torso sizing. The active system consists of a series of pressurizable nastic cells embedded into the fabric layers of a spacesuit SUT. These cells are integrated to the front and back of the SUT and are connected to an air source with a variable regulator. When inflated, the nastic cells provide a change in the overall shoulder bearing breadth of the spacesuit and thus, torso sizing. The research focused on the development of a high-performance sizing and actuation system. This technology has application as a suit-sizing mechanism to allow easier suit entry and more accurate suit fit with fewer torso sizes than the existing EMU (Extravehicular Mobility Unit) suit system. This advanced SUT will support NASA s Advanced EMU Evolutionary Concept of a two-sizes-fit-all upper torso for replacement of the current EMU hard upper torso (HUT). Both the passive and nastic sizing system approaches provide astronauts with real-time upper torso sizing, which translates into a more comfortable suit, providing enhanced fit resulting in improved crewmember performance during extravehicular activity. These systems will also benefit NASA by reducing flight logistics as well as overall suit system cost. The nastic sizing system approach provides additional structural redundancy over existing SUT designs by embedding additional coated fabric and uncoated fabric layers. Two sizing systems were selected to build into a prototype SUT: one active and one passive. From manned testing, it was found that both systems offer good solutions to sizing a SUT to fit a crewmember. This new system provided improved suit don/doff over existing spacesuit designs as well as providing better fit at suit operational pressure resulting in improved comfort and mobility. It was found that a SUT with a sizing system may solve several problems that have plagued existing HUT designs, and that a SUT with a sizing system may be a viable option for advanced suit architectures.

  17. Relationship Among Anal Sphincter Injury, Patulous Anal Canal, and Anal Pressures in Patients with Anorectal Disorders

    PubMed Central

    Prichard, David; Harvey, Doris M.; Fletcher, Joel G.; Zinsmeister, Alan R.; Bharucha, Adil E.

    2015-01-01

    Background & Aims The anal sphincters and puborectalis are routinely imaged with an endoanal magnetic resonance imaging (MRI) coil, which does not assess co-aptation of the anal canal at rest. Using a MRI torso coil, we identified a patulous anal canal in some patients with anorectal disorders. We aimed to evaluate the relationship between anal sphincter and puborectalis injury, a patulous anal canal, and anal pressures. Methods We performed a retrospective analysis of data from 119 patients who underwent MRI and manometry analysis of anal anatomy and pressures, respectively, from February 2011 through March 2013 at the Mayo Clinic. Anal pressures were determined by high-resolution manometry, anal sphincter and puborectalis injury was determined by endoanal MRI, and anal canal integrity was determined by torso MRI. Associations between manometric and anatomical parameters were evaluated with univariate and multivariate analyses. Results Fecal incontinence (55 patients, 46%) and constipation (36 patients. 30%) were the main indications for testing; 49 patients (41%) had a patulous anal canal, which was associated with injury to more than 1 muscle (all P≤.001) and internal sphincter (P<.01), but not puborectalis (P=.09) or external sphincter (P=.06) injury. Internal (P<.01) and external sphincter injury (P=.02) and a patulous canal (P<.001), but not puborectalis injury, predicted anal resting pressure. A patulous anal canal was the only significant predictor (P<.01) of the anal squeeze pressure increment. Conclusions Patients with anorectal disorders commonly have a patulous anal canal, associated with more severe anal injury, anal resting pressure, and squeeze pressure increment. It is therefore important to identify patulous anal canal because it appears to be a marker of not only anal sphincter injury but disturbances beyond sphincter injury, such as damage to the anal cushions or anal denervation. PMID:25869638

  18. Negative Rotation Cinch Strap.

    DTIC Science & Technology

    This project discloses an improved unitary parachute torso harness, having a single fastening means, wherein an auxillary tightening strap is...attached to the groin straps of said harness. Said auxillary straps are used to prevent torso rotation or harness slippage and to prevent harness elongation

  19. Torso-Tank Validation of High-Resolution Electrogastrography (EGG): Forward Modelling, Methodology and Results.

    PubMed

    Calder, Stefan; O'Grady, Greg; Cheng, Leo K; Du, Peng

    2018-04-27

    Electrogastrography (EGG) is a non-invasive method for measuring gastric electrical activity. Recent simulation studies have attempted to extend the current clinical utility of the EGG, in particular by providing a theoretical framework for distinguishing specific gastric slow wave dysrhythmias. In this paper we implement an experimental setup called a 'torso-tank' with the aim of expanding and experimentally validating these previous simulations. The torso-tank was developed using an adult male torso phantom with 190 electrodes embedded throughout the torso. The gastric slow waves were reproduced using an artificial current source capable of producing 3D electrical fields. Multiple gastric dysrhythmias were reproduced based on high-resolution mapping data from cases of human gastric dysfunction (gastric re-entry, conduction blocks and ectopic pacemakers) in addition to normal test data. Each case was recorded and compared to the previously-presented simulated results. Qualitative and quantitative analyses were performed to define the accuracy showing [Formula: see text] 1.8% difference, [Formula: see text] 0.99 correlation, and [Formula: see text] 0.04 normalised RMS error between experimental and simulated findings. These results reaffirm previous findings and these methods in unison therefore present a promising morphological-based methodology for advancing the understanding and clinical applications of EGG.

  20. Posture and re-positioning considerations of a complete torso topographic analysis system for assessing scoliosis

    NASA Astrophysics Data System (ADS)

    Ajemba, Peter O.; Durdle, Nelson G.; Hill, Doug L.; Raso, V. J.

    2006-02-01

    The influence of posture and re-positioning (sway and breathing) on the accuracy of a torso imaging system for assessing scoliosis was evaluated. The system comprised of a rotating positioning platform and one or two laser digitizers. It required four partial-scans taken at 90 ° intervals over 10 seconds to generate two complete torso scans. Its accuracy was previously determined to be 1.1+/-0.9mm. Ten evenly spaced cross-sections obtained from forty scans of five volunteers in four postures (free-standing, holding side supports, holding front supports and with their hands on their shoulders) were used to assess the variability due to posture. Twenty cross-sections from twenty scans of two volunteers holding side supports were used to assess the variability due to positioning. The variability due to posture was less than 4mm at each cross-section for all volunteers. Variability due to sway ranged from 0-3.5mm while that due to breathing ranged from 0-3mm for both volunteers. Holding side supports was the best posture. Taking the four shots within 10 seconds was optimal. As major torso features that are indicative of scoliosis are larger than 4mm in size, the system could be used in obtaining complete torso images used in assessing and managing scoliosis.

  1. Internal Motion Estimation by Internal-external Motion Modeling for Lung Cancer Radiotherapy.

    PubMed

    Chen, Haibin; Zhong, Zichun; Yang, Yiwei; Chen, Jiawei; Zhou, Linghong; Zhen, Xin; Gu, Xuejun

    2018-02-27

    The aim of this study is to develop an internal-external correlation model for internal motion estimation for lung cancer radiotherapy. Deformation vector fields that characterize the internal-external motion are obtained by respectively registering the internal organ meshes and external surface meshes from the 4DCT images via a recently developed local topology preserved non-rigid point matching algorithm. A composite matrix is constructed by combing the estimated internal phasic DVFs with external phasic and directional DVFs. Principle component analysis is then applied to the composite matrix to extract principal motion characteristics, and generate model parameters to correlate the internal-external motion. The proposed model is evaluated on a 4D NURBS-based cardiac-torso (NCAT) synthetic phantom and 4DCT images from five lung cancer patients. For tumor tracking, the center of mass errors of the tracked tumor are 0.8(±0.5)mm/0.8(±0.4)mm for synthetic data, and 1.3(±1.0)mm/1.2(±1.2)mm for patient data in the intra-fraction/inter-fraction tracking, respectively. For lung tracking, the percent errors of the tracked contours are 0.06(±0.02)/0.07(±0.03) for synthetic data, and 0.06(±0.02)/0.06(±0.02) for patient data in the intra-fraction/inter-fraction tracking, respectively. The extensive validations have demonstrated the effectiveness and reliability of the proposed model in motion tracking for both the tumor and the lung in lung cancer radiotherapy.

  2. A Field Data Analysis of Risk Factors Affecting the Injury Risks in Vehicle-To-Pedestrian Crashes

    PubMed Central

    Zhang, Guanjun; Cao, Libo; Hu, Jingwen; Yang, King H.

    2008-01-01

    The head, torso, and lower extremity are the most commonly injured body regions during vehicle-to-pedestrian crashes. A total of 312 cases were selected from the National Automotive Sampling System (NASS) Pedestrian Crash Data Study (PCDS) database to investigate factors affecting the likelihood of sustaining MAIS 3+, AIS 3+ head, AIS 3+ torso, and AIS 2+ lower extremity injuries during vehicle-to-pedestrian frontal crashes. The inclusion criteria were pedestrians: (a) aged 14 years or older, (b) with a height of 1.5 m and taller, and (c) who were injured in an upright standing position via vehicle frontal collision. The injury odds ratios (ORs) calculated from logistic regression analyses were used to evaluate the association between selected injury predictors and the odds of sustaining pedestrian head, torso, and lower extremity injuries. These predictors included a crash factor (impact speed), pedestrian factors (age, gender, height, and weight), and vehicle factors (front bumper central height, front bumper lead, ground to front/top transition point height (FTTPH), and rear hood opening distance (RHOD)). Results showed that impact speed was a statistically significant predictor for head, torso, and lower extremity injury odds, as expected. Comparison of people 65 years of age and older to young adults aged 14 to 64 showed that age was also a significant predictor for torso (p<0.001, OR=23.8) and lower extremity (p=0.020, OR=2.44) injury odds, but not for head injuries (p=0.661). Vehicles with higher FTTPH and more vertical frontal structures were aggressive to pedestrians, especially regarding injuries to the torso. A very short RHOD would be more likely to lead the pedestrian to impact the windshield and windshield frame, thus increasing the head injury risk. PMID:19026237

  3. Upper torso and pelvis linear velocity during the downswing of elite golfers

    PubMed Central

    2013-01-01

    Background During a golf swing, analysis of the movement in upper torso and pelvis is a key step to determine a motion control strategy for accurate and consistent shots. However, a majority of previous studies that have evaluated this movement limited their analysis only to the rotational movement of segments, and translational motions were not examined. Therefore, in this study, correlations between translational motions in the 3 axes, which occur between the upper torso and pelvis, were also examined. Methods The experiments were carried out with 14 male pro-golfers (age: 29 ± 8 years, career: 8.2 ± 4.8years) who registered in the Korea Professional Golf Association (KPGA). Six infrared cameras (VICON; Oxford Metrics, Oxford, UK) and SB-Clinc software (SWINGBANK Ltd, Korea) were used to collect optical marker trajectories. The center of mass (CoM) of each segment was calculated based on kinematic principal. In addition, peak value of CoM velocity and the time that each peak occurred in each segment during downswing was calculated. Also, using cross-correlation analysis, the degree of coupling and time lags of peak values occurred between and within segments (pelvis and upper torso) were investigated. Results As a result, a high coupling strength between upper torso and pelvis with an average correlation coefficient = 0.86 was observed, and the coupling between segments was higher than that within segments (correlation coefficient = 0.81 and 0.77, respectively). Conclusions Such a high coupling at the upper torso and pelvis can be used to reduce the degree of motion control in the central nervous system and maintain consistent patterns in the movement. The result of this study provides important information for the development of optimal golf swing movement control strategies in the future. PMID:23398693

  4. Estimation of regional cutaneous cold sensitivity by analysis of the gasping response.

    PubMed

    Burke, W E; Mekjavić, I B

    1991-11-01

    Regional cutaneous sensitivity to cooling was assessed in males by separately immersing four discrete skin regions in cold water (15 degrees C) during head-out immersion. The response measured was gasping at the onset of immersion; the gasping response appears to be the result of a nonthermoregulatory neurogenic drive from cutaneous cold receptors. Subjects of similar body proportions wore a neoprene "dry" suit modified to allow exposure to the water of either the arms, upper torso, lower torso, or legs, while keeping the unexposed skin regions thermoneutral. Each subject was immersed to the sternal notch in all four conditions of partial exposure plus one condition of whole body exposure. The five cold water conditions were matched by control immersions in lukewarm (34 degrees C) water, and trials were randomized. The magnitude of the gasping response was determined by mouth occlusion pressure (P0.1). For each subject, P0.1 values for the 1st min of immersion were integrated, and control trial values, although minimal, were subtracted from their cold water counterpart to account for any gasping due to the experimental design. Results were averaged and showed that the highest P0.1 values were elicited from whole body exposure, followed in descending order by exposures of the upper torso, legs, lower torso, and arms. Correction of the P0.1 response for differences in exposed surface area (A) and cooling stimulus (delta T) between regions gave a cold sensitivity index [CSI, P0.1/(A.delta T)] for each region and showed that the index for the upper torso was significantly higher than that for the arms or legs; no significant difference was observed between the indexes for the upper and lower torso.(ABSTRACT TRUNCATED AT 250 WORDS)

  5. The effect of technique change on knee loads during sidestep cutting.

    PubMed

    Dempsey, Alasdair R; Lloyd, David G; Elliott, Bruce C; Steele, Julie R; Munro, Bridget J; Russo, Kylie A

    2007-10-01

    To identify the effect of modifying sidestep cutting technique on knee loads and predict what impact such change would have on the risk of noncontact anterior cruciate ligament injury. A force platform and motion-analysis system were used to record ground-reaction forces and track the trajectories of markers on 15 healthy males performing sidestep cutting tasks using their normal technique and nine different imposed techniques. A kinematic and inverse dynamic model was used to calculate the three-dimensional knee postures and moments. The imposed techniques of foot wide and torso leaning in the opposite direction to the cut resulted in increased peak valgus moments experienced in weight acceptance. Higher peak internal rotation moments were found for the foot wide and torso rotation in the opposite direction to the cut techniques. The foot rotated in technique resulted in lower mean flexion/extension moments, whereas the foot wide condition resulted in higher mean flexion/extension moments. The flexed knee, torso rotated in the opposite direction to the cut and torso leaning in the same direction as the cut techniques had significantly more knee flexion at heel strike. Sidestep cutting technique had a significant effect on loads experienced at the knee. The techniques that produced higher valgus and internal rotation moments at the knee, such as foot wide, torso leaning in the opposite direction to the cut and torso rotating in the opposite direction to the cut, may place an athlete at higher risk of injury because these knee loads have been shown to increase the strain on the anterior cruciate ligament. Training athletes to avoid such body positions may result in a reduced risk of noncontact anterior cruciate ligament injures.

  6. Biomechanics of volunteers subject to loading by a motorized shoulder belt tensioner.

    PubMed

    Good, Craig A; Viano, David C; Ronsky, Janet L

    2008-04-15

    A biomechanical study using human volunteers. Motorized shoulder belt tensioning is a new seatbelt technology that is likely to be incorporated into future vehicles. The objective of this study was to characterize the upper torso biomechanics of 3 sizes of adult volunteers (5th percentile female, 50th percentile male, and 95th percentile male) subjected to motorized shoulder belt tensioning in the static environment. There is a lack of volunteer data concerning the biomechanics of occupants subject to motorized precrash shoulder belt tensioning. Studies of torso repositioning by the air force for ejection seats are much too aggressive to be relevant to motorized systems. Low-level motorized shoulder belt tensioning is well tolerated by vehicle occupants but optimized performance by occupant size is unknown. Nineteen male and 6 female subjects were instrumented in a fixture designed to support the occupant leaning forward and apply seatbelt tension. The subjects were 5th percentile females, 50th percentile males, and 95th percentile males. Reflective markers were placed on the subjects to monitor torso kinematics during tensioning. Changes in spinal curvature were small during shoulder belt tensioning and the angular motion of the torso originated within 4.2 cm of the pelvis-femur junction or H-point. Torso repositioning and retraction timing was found to be: 54.3 degrees in 0.78 seconds for the 5th percentile female, 57.6 degrees in 0.95 seconds for the 50th percentile male, and 42.2 degrees in 0.92 seconds for the 95th percentile male. Occupant size has a significant effect on retraction time to reposition the torso during shoulder belt tensioning. Larger vehicle occupants require more time because of a slower retraction velocity. The results are sufficiently simple that a lumped-mass model can predict tensioning kinetics.

  7. Upper torso and pelvis linear velocity during the downswing of elite golfers.

    PubMed

    Beak, Seung-Hui; Choi, Ahnryul; Choi, Seung-Wook; Oh, Seung Eel; Mun, Joung Hwan; Yang, Heegoo; Sim, Taeyong; Song, Hae-Ryong

    2013-02-11

    During a golf swing, analysis of the movement in upper torso and pelvis is a key step to determine a motion control strategy for accurate and consistent shots. However, a majority of previous studies that have evaluated this movement limited their analysis only to the rotational movement of segments, and translational motions were not examined. Therefore, in this study, correlations between translational motions in the 3 axes, which occur between the upper torso and pelvis, were also examined. The experiments were carried out with 14 male pro-golfers (age: 29 ± 8 years, career: 8.2 ± 4.8years) who registered in the Korea Professional Golf Association (KPGA). Six infrared cameras (VICON; Oxford Metrics, Oxford, UK) and SB-Clinc software (SWINGBANK Ltd, Korea) were used to collect optical marker trajectories. The center of mass (CoM) of each segment was calculated based on kinematic principal. In addition, peak value of CoM velocity and the time that each peak occurred in each segment during downswing was calculated. Also, using cross-correlation analysis, the degree of coupling and time lags of peak values occurred between and within segments (pelvis and upper torso) were investigated. As a result, a high coupling strength between upper torso and pelvis with an average correlation coefficient = 0.86 was observed, and the coupling between segments was higher than that within segments (correlation coefficient = 0.81 and 0.77, respectively). Such a high coupling at the upper torso and pelvis can be used to reduce the degree of motion control in the central nervous system and maintain consistent patterns in the movement. The result of this study provides important information for the development of optimal golf swing movement control strategies in the future.

  8. Do current sports brassiere designs impede respiratory function?

    PubMed

    Bowles, Kelly-Ann; Steele, Julie R; Chaunchaiyakul, Rungchai

    2005-09-01

    Although sports brassieres are more effective in limiting breast motion and related breast pain when compared with standard fashion brassieres, some females do not wear sports brassieres during physical activity, as they perceive them to be too tight around the torso, possibly impeding their performance during physical activity. The purpose of this study was to determine whether breast hypertrophy, breast momentum, and/or wearing a sports brassiere impeded respiratory function at rest and during physical activity. Twenty-two active women completed standard resting spirometry maneuvers while not wearing a brassiere. All subjects then completed maximal cycle ergometer testing in two breast support conditions (sports brassiere and no brassiere (NB)), followed by submaximal treadmill exercise tests under three breast support conditions (sports brassiere, no brassiere and fashion brassiere) while standard spirometry, brassiere pressure and comfort were measured. The sports brassiere imparted significantly more pressure on smaller breasted females' torsos when compared with the fashion brassiere (0.861 +/- 0.247 and 0.672 +/- 0.254 N.cm(-2), respectively), although this increased pressure did not appear to significantly affect measured lung volumes or brassiere comfort scores. Brassiere size affected maximal exercise ability (relative VO(2peak): smaller breasted NB: 49.84 +/- 6.15 mL.kg(-1).min(-1); larger breasted NB: 40.76 +/- 4.47 mL.kg(-1).min(-1)) as well as some temporal measures of resting and submaximal respiration. However, no significant difference was found between the no brassiere and brassiere conditions in regards to measured lung volumes. As no significant restriction to exercise performance or respiratory mechanics was found when subjects wore sports brassieres, it was concluded that active females should wear a sports brassiere during physical activity to reduce breast motion and related breast pain.

  9. Effect of excessive contralateral trunk tilt on pitching biomechanics and performance in high school baseball pitchers.

    PubMed

    Oyama, Sakiko; Yu, Bing; Blackburn, J Troy; Padua, Darin A; Li, Li; Myers, Joseph B

    2013-10-01

    There is a growing number of pitching-related upper extremity injuries among young baseball pitchers; however, there is a lack of data on the identification of injury prevention strategies, particularly the prevention of injuries through the instruction/modification of technique. The identification of technical parameters that are associated with increased joint loading is needed. To investigate the effects of excessive contralateral trunk tilt, a common technique identifiable by video observation, on pitching biomechanics and performance in high school baseball pitchers. The hypothesis was that this strategy is associated with greater joint loading and poor pitching performance. Descriptive laboratory study; Level of evidence, 3. The 3-dimensional pitching biomechanics, ball speed, and frontal view of the pitching technique from 72 high school baseball pitchers were captured on video and analyzed. The videos were reviewed to determine if the pitcher's trunk was excessively contralaterally tilted at the instant of maximal shoulder external rotation by examining whether the side of the pitcher's head ipsilateral to the throwing limb deviated by more than a head width from a vertical line passing through the pitcher's stride foot ankle. Upper extremity kinetics and upper extremity/trunk kinematics between pitchers with and without excessive contralateral trunk tilt were compared using independent t tests. Compared with pitchers who did not demonstrate excessive contralateral trunk tilt, those with excessive contralateral trunk tilt pitched at a higher ball speed (mean, 32.6 ± 2.2 vs 31.1 ± 2.9 m/s, respectively; P = .019) and experienced a greater elbow proximal force (mean, 103.9 ± 12.7 vs 93.2 ± 13.9 %weight, respectively; P = .001), shoulder proximal force (mean, 104.8 ± 14.1 vs 94.3 ± 15.5 %weight, respectively; P = .004), elbow varus moment (mean, 4.29 ± 0.73 vs 3.84 ± 0.8 %height*weight, respectively; P = .017), and shoulder internal rotation moment (mean, 4.21 ± 0.71 vs 3.75 ± 0.78 %height*weight, respectively; P = .011). Pitchers with excessive contralateral trunk tilt demonstrated less upper torso flexion at stride foot contact, less upper torso rotation, and greater upper torso contralateral flexion at maximal shoulder external rotation and ball release (P < .05). Excessive contralateral trunk tilt is a strategy that is associated with higher ball speeds and increased joint loading. Pitching with excessive contralateral trunk tilt, which can be identified through screening of the pitching technique, is associated with a benefit in performance and increased joint loading. Future study is warranted to determine if this strategy should be encouraged or discouraged by baseball coaches.

  10. Effects of work experience on fatigue-induced biomechanical changes during repetitive asymmetric lifts/lowers.

    PubMed

    Lee, Jungyong; Nussbaum, Maury A; Kyung, Gyouhyung

    2014-01-01

    Repetitive lifting/lowering is associated with an increased risk of work-related low back disorders (WRLBDs), and fatigue may exacerbate such risk. Work methods used by experienced workers are potential models for developing worker training to reduce WRLBDs, though whether experience modifies the effects of fatigue on WRLBD risk is largely unknown. Here, six novices and six experienced workers completed 185 cycles of repetitive, asymmetric lifts/lowers. Physical demands, whole-body balance and torso movement stability were assessed using torso kinematics/kinetics, linear/angular momenta and Lyapunov exponents, respectively. Several fatigue-induced changes in movement strategies were evident. Novices decreased and experienced workers increased peak lumbar moments post-fatigue, suggesting lower WRLBD risks among the former in terms of torso kinetics. Other than lumbar moments, though, fatigue substantially reduced group-level differences in torso twisting velocities and accelerations. Post-fatigue movement strategies of experienced workers thus did not appear to be advantageous in terms of WRLBD risk.

  11. Phantom Torso in HRF section of Destiny module

    NASA Image and Video Library

    2001-05-02

    ISS002-E-6080 (2 May 2001) --- The Phantom Torso, seen here in the Human Research Facility (HRF) section of the Destiny/U.S. laboratory on the International Space Station (ISS), is designed to measure the effects of radiation on organs inside the body by using a torso that is similar to those used to train radiologists on Earth. The torso is equivalent in height and weight to an average adult male. It contains radiation detectors that will measure, in real-time, how much radiation the brain, thyroid, stomach, colon, and heart and lung area receive on a daily basis. The data will be used to determine how the body reacts to and shields its internal organs from radiation, which will be important for longer duration space flights. The experiment was delivered to the orbiting outpost during by the STS-100/6A crew in April 2001. Dr. Gautam Badhwar, NASA JSC, Houston, TX, is the principal investigator for this experiment. A digital still camera was used to record this image.

  12. Implementation of a close range photogrammetric system for 3D reconstruction of a scoliotic torso

    NASA Astrophysics Data System (ADS)

    Detchev, Ivan Denislavov

    Scoliosis is a deformity of the human spine most commonly encountered with children. After being detected, periodic examinations via x-rays are traditionally used to measure its progression. However, due to the increased risk of cancer, a non-invasive and radiation-free scoliosis detection and progression monitoring methodology is needed. Quantifying the scoliotic deformity through the torso surface is a valid alternative, because of its high correlation with the internal spine curvature. This work proposes a low-cost multi-camera photogrammetric system for semi-automated 3D reconstruction of a torso surface with sub-millimetre level accuracy. The thesis describes the system design and calibration for optimal accuracy. It also covers the methodology behind the reconstruction and registration procedures. The experimental results include the complete reconstruction of a scoliotic torso mannequin. The final accuracy is evaluated through the goodness of fit between the reconstructed surface and a more accurate set of points measured by a coordinate measuring machine.

  13. Towards quantitative PET/MRI: a review of MR-based attenuation correction techniques.

    PubMed

    Hofmann, Matthias; Pichler, Bernd; Schölkopf, Bernhard; Beyer, Thomas

    2009-03-01

    Positron emission tomography (PET) is a fully quantitative technology for imaging metabolic pathways and dynamic processes in vivo. Attenuation correction of raw PET data is a prerequisite for quantification and is typically based on separate transmission measurements. In PET/CT attenuation correction, however, is performed routinely based on the available CT transmission data. Recently, combined PET/magnetic resonance (MR) has been proposed as a viable alternative to PET/CT. Current concepts of PET/MRI do not include CT-like transmission sources and, therefore, alternative methods of PET attenuation correction must be found. This article reviews existing approaches to MR-based attenuation correction (MR-AC). Most groups have proposed MR-AC algorithms for brain PET studies and more recently also for torso PET/MR imaging. Most MR-AC strategies require the use of complementary MR and transmission images, or morphology templates generated from transmission images. We review and discuss these algorithms and point out challenges for using MR-AC in clinical routine. MR-AC is work-in-progress with potentially promising results from a template-based approach applicable to both brain and torso imaging. While efforts are ongoing in making clinically viable MR-AC fully automatic, further studies are required to realize the potential benefits of MR-based motion compensation and partial volume correction of the PET data.

  14. Non-destructive elemental analysis of vertebral body trabecular bone using muonic X-rays.

    PubMed

    Hosoi, Y; Watanabe, Y; Sugita, R; Tanaka, Y; Nagamine, K; Ono, T; Sakamoto, K

    1995-12-01

    Non-destructive elemental analysis with muonic X-rays was performed on human vertebral bone and lumbar torso phantoms. It can provide quantitative information on all elements in small deep-seated localized volumes. The experiment was carried out using the superconducting muon channel at TRIUMF in Vancouver, Canada and a lithium drifted germanium detector with an active area of 18.5 cm2. The muon channel produced backward-decayed negative muons with wide kinetic energy range from 0.5 to 54.2 MeV. The muon beam was collimated to a diameter of 18 mm. The number of incoming muons was about 4 x 10(6) approximately 5 x 10(7) per data point. In the measurements with human vertebral bones fixed with neutralized formaldehyde, the correlation coefficient between calcium content measured by muons and by atomic absorption analysis was 0.99 and the level of significance was 0.0003. In the measurements with lumbar torso phantoms, the correlation coefficient between calcium content measured by muons and by atomic absorption analysis was 0.99 and the level of significance was 0.02. The results suggest that elemental analysis in vertebral body trabecular bone using muonic X-rays closely correlates with measurements by atomic absorption analysis.

  15. Multimodality imaging features, metastatic pattern and clinical outcome in adult extraskeletal Ewing sarcoma: experience in 26 patients

    PubMed Central

    Somarouthu, B S; Shinagare, A B; Rosenthal, M H; Hornick, J L; Ramaiya, N H

    2014-01-01

    Objective: To describe the multimodality imaging features, metastatic pattern and clinical outcome in adult extraskeletal Ewing sarcoma (EES). Methods: In this institutional review board–approved, health insurance portability and accountability act–compliant retrospective study, we included 26 patients (17 females and 9 males; mean age, 36 years; range, 18–85 years) with pathologically confirmed EES seen at our institute between 1999 and 2011, who had imaging of primary tumour. Imaging of primary tumour in all 26 patients and follow-up imaging in 23 was reviewed by two radiologists in consensus. Clinical data were extracted from electronic medical records. Results: The most common primary sites were the torso (n = 13), extremities (n = 10) and head and neck (HN) region (n = 3). The mean tumour size was 9 cm (range, 3–22 cm); tumours of the torso were larger than those of other areas (p > 0.05). Compared with the skeletal muscle, tumours were isodense on CT (21/21), hypointense (n = 5) to isointense (n = 14) on T1 weighted image, hyperintense on T2 weighted image (19/19) and were fluorine-18 fludeoxyglucose (18F-FDG)-avid [10/10; mean maximum standardized uptake value of 7 (range, 3–11)]. Necrosis (15/26), haemorrhage (5/26) and adjacent organ invasion (14/26) were present without calcification. Median follow-up was 16 months. 5 patients had local recurrence (torso, 3; extremity, 1; and HN, 1). Metastases developed in 11 patients (torso, 7; extremities, 3; and HN, 1; p > 0.05); 8 at presentation, most commonly to lung (9/11), peritoneum (4/11), muscles (4/11) and lymph nodes (4/11). Nine patients (torso, 7; extremity, 1; and HN, 1) died (10 months median survival) (p > 0.05). Conclusion: Adult EESs are large tumours, which frequently invade adjacent organs and metastasize to the lung. EESs of the torso are larger, have more frequent metastases and poorer outcomes. Advances in knowledge: Adult EESs of the torso have poor outcomes compared with other EESs. PMID:24734938

  16. Comparison of different strongman events: trunk muscle activation and lumbar spine motion, load, and stiffness.

    PubMed

    McGill, Stuart M; McDermott, Art; Fenwick, Chad Mj

    2009-07-01

    Strongman events are attracting more interest as training exercises because of their unique demands. Further, strongman competitors sustain specific injuries, particularly to the back. Muscle electromyographic data from various torso and hip muscles, together with kinematic measures, were input to an anatomically detailed model of the torso to estimate back load, low-back stiffness, and hip torque. Events included the farmer's walk, super yoke, Atlas stone lift, suitcase carry, keg walk, tire flip, and log lift. The results document the unique demands of these whole-body events and, in particular, the demands on the back and torso. For example, the very large moments required at the hip for abduction when performing a yoke walk exceed the strength capability of the hip. Here, muscles such as quadratus lumborum made up for the strength deficit by generating frontal plane torque to support the torso/pelvis. In this way, the stiffened torso acts as a source of strength to allow joints with insufficient strength to be buttressed, resulting in successful performance. Timing of muscle activation patterns in events such as the Atlas stone lift demonstrated the need to integrate the hip extensors before the back extensors. Even so, because of the awkward shape of the stone, the protective neutral spine posture was impossible to achieve, resulting in substantial loading on the back that is placed in a weakened posture. Unexpectedly, the super yoke carry resulted in the highest loads on the spine. This was attributed to the weight of the yoke coupled with the massive torso muscle cocontraction, which produced torso stiffness to ensure spine stability together with buttressing the abduction strength insufficiency of the hips. Strongman events clearly challenge the strength of the body linkage, together with the stabilizing system, in a different way than traditional approaches. The carrying events challenged different abilities than the lifting events, suggesting that loaded carrying would enhance traditional lifting-based strength programs. This analysis also documented the technique components of successful, joint-sparing, strongman event strategies.

  17. Optimum location of external markers using feature selection algorithms for real-time tumor tracking in external-beam radiotherapy: a virtual phantom study.

    PubMed

    Nankali, Saber; Torshabi, Ahmad Esmaili; Miandoab, Payam Samadi; Baghizadeh, Amin

    2016-01-08

    In external-beam radiotherapy, using external markers is one of the most reliable tools to predict tumor position, in clinical applications. The main challenge in this approach is tumor motion tracking with highest accuracy that depends heavily on external markers location, and this issue is the objective of this study. Four commercially available feature selection algorithms entitled 1) Correlation-based Feature Selection, 2) Classifier, 3) Principal Components, and 4) Relief were proposed to find optimum location of external markers in combination with two "Genetic" and "Ranker" searching procedures. The performance of these algorithms has been evaluated using four-dimensional extended cardiac-torso anthropomorphic phantom. Six tumors in lung, three tumors in liver, and 49 points on the thorax surface were taken into account to simulate internal and external motions, respectively. The root mean square error of an adaptive neuro-fuzzy inference system (ANFIS) as prediction model was considered as metric for quantitatively evaluating the performance of proposed feature selection algorithms. To do this, the thorax surface region was divided into nine smaller segments and predefined tumors motion was predicted by ANFIS using external motion data of given markers at each small segment, separately. Our comparative results showed that all feature selection algorithms can reasonably select specific external markers from those segments where the root mean square error of the ANFIS model is minimum. Moreover, the performance accuracy of proposed feature selection algorithms was compared, separately. For this, each tumor motion was predicted using motion data of those external markers selected by each feature selection algorithm. Duncan statistical test, followed by F-test, on final results reflected that all proposed feature selection algorithms have the same performance accuracy for lung tumors. But for liver tumors, a correlation-based feature selection algorithm, in combination with a genetic search algorithm, proved to yield best performance accuracy for selecting optimum markers.

  18. In vitro methods for evaluating skin hydration under diapers and incontinence products.

    PubMed

    Tate, M L; Wright, A S

    2017-11-01

    Excessive skin hydration from wearing wet undergarments, such as infant diapers and adult incontinence products, has been historically problematic. Skin damage occurs from wetness (urine) and limited product breathability. Evaporative water loss has been measured on adult arms (armband method) or infant torsos (on-baby method), after wearing a saline-insulted diaper product. The current study developed a reliable in vitro method of evaluating diaper and incontinence products for improvements in skin dryness. A simulated skin substrate was applied to a heated mechanical arm or baby torso. A disposable diaper or incontinence product was wrapped around the arm or baby torso, and loaded with saline. Hydration of the simulated skin was measured by evaporimetry and compared with clinical data from adult armband evaluations. The heated mechanical arm and baby torso accurately distinguished products for skin dryness. Eight diaper products were evaluated and compared to human test results. The torso in vitro and mechanical arm evaluations demonstrated strong correlations to human epidermal water loss evaluations, with repeatable results. Additionally, the bench test has been used for adult incontinence products, and it proved to differentiate those products as well as infant products. A rapid and reliable means of evaluation has been developed, and it is predictive of human subject testing. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. RM-10A robotic manipulator system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    White, J.R.; Coughlan, J.B.; Harvey, H.W.

    1988-01-01

    The REMOTE RM-10A is a man-replacement manipulator system that has been developed specifically for use in radioactive and other hazardous environments. It can be teleoperated, with man-in-the-loop, for unstructured tasks or programmed to perform routine tasks automatically much like robots in the automated manufacturing industry. The RM-10A is a servomanipulator utilizing a closed-loop, microprocessor-based control system. The system consists of a slave assembly, master control station, and interconnecting cabling. The slave assembly is the part of the system that enters the hostile environment. It is man-like is size and configuration with two identical arms attached to a torso structure. Eachmore » arm attaches to the torso using two captive screws and two guide pins. The guide pins position and stabilize an arm during removal and reinstallation and also align the two electrical connectors located in the arm support plate and torso. These features allow easy remote replacement of an arm, and commonality of the arms allow interchangeability. The water-resistant slave assembly is equipped with gaskets and O-ring seals in the torso and arm and camera assemblies. In addition, each slave arm's elbow, wrist, and tong are protected by replaceable polyurethane boots. An upper camera assembly, consisting of a color television (TV) camera, 6:1 zoom lens, and a pan/tilt unit, mount to the torso to provide remote viewing capability.« less

  20. Experimental impact protection with advanced restraint systems : preliminary primate with air bag and inertia reel/inverted-y yoke torso harness.

    DOT National Transportation Integrated Search

    1969-02-01

    Both the inverted-Y yoke torso harness with inertia reel and the air- bag restraint system have had extensive independent development for some time by several engineering and research organizations for both aviation and ground vehicle occupant protec...

  1. 49 CFR 572.135 - Upper and lower torso assemblies and torso flexion test procedure.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... orientation angle may not exceed 20 degrees. (8) Attach the pull cable and the load cell as shown in Figure O4. (9) Apply a tension force in the midsagittal plane to the pull cable as shown in Figure O4 at any...

  2. 49 CFR 572.198 - Pelvis acetabulum.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 7 2012-10-01 2012-10-01 false Pelvis acetabulum. 572.198 Section 572.198... Dummy, Small Adult Female § 572.198 Pelvis acetabulum. (a) The acetabulum is part of the lower torso... torso of the assembled dummy (drawing 180-0000). The dummy is equipped with a laterally oriented pelvis...

  3. 49 CFR 572.198 - Pelvis acetabulum.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 7 2011-10-01 2011-10-01 false Pelvis acetabulum. 572.198 Section 572.198... Dummy, Small Adult Female § 572.198 Pelvis acetabulum. (a) The acetabulum is part of the lower torso... torso of the assembled dummy (drawing 180-0000). The dummy is equipped with a laterally oriented pelvis...

  4. Computer Simulation of an Aircraft Seat and Occupant in a Crash Environment. Volume 1. Technical Report

    DTIC Science & Technology

    1983-03-01

    q18 q2 8 q 2 q1 9 = 06q 2 9 812 7 (11)1q0 3 q 2 0 : ś The above coordinates include the Cartesian coordinates of the mass ce-nter of segment 1 ( Xl ...l P0 zC SC Lap Lap belt anchor point ( XL ’ YL’ ZL) 0 Inertial coordinate system Figure 30. Forces acting on occupant torso (nose-down attitude). 87...position calculated by equation (104) for the level flight assumption. The angle is defined according to 0 = sin-- ZL)/ X - XL )2 + (Zp - ZL)2 (106

  5. Toward noninvasive monitoring of ongoing electrical activity of human uterus and fetal heart and brain.

    PubMed

    Lew, S; Hämäläinen, M S; Okada, Y

    2017-12-01

    To evaluate whether a full-coverage fetal-maternal scanner can noninvasively monitor ongoing electrophysiological activity of maternal and fetal organs. A simulation study was carried out for a scanner with an array of magnetic field sensors placed all around the torso from the chest to the hip within a horizontal magnetic shielding enclosure. The magnetic fields from internal organs and an external noise source were computed for a pregnant woman with a 35-week old fetus. Signal processing methods were used to reject the external and internal interferences, to visualize uterine activity, and to detect activity of fetal heart and brain. External interference was reduced by a factor of 1000, sufficient for detecting signals from internal organs when combined with passive and active shielding. The scanner rejects internal interferences better than partial-coverage arrays. It can be used to estimate currents around the uterus. It clearly detects spontaneous activity from the fetal heart and brain without averaging and weaker evoked brain activity at all fetal head positions after averaging. The simulated device will be able to monitor the ongoing activity of the fetal and maternal organs. This type of scanner may become a novel tool in fetal medicine. Copyright © 2017 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.

  6. Humanoid Robot

    NASA Technical Reports Server (NTRS)

    Linn, Douglas M. (Inventor); Mehling, Joshua S. (Inventor); Radford, Nicolaus A. (Inventor); Bridgwater, Lyndon (Inventor); Wampler, II, Charles W. (Inventor); Abdallah, Muhammad E. (Inventor); Sanders, Adam M. (Inventor); Davis, Donald R. (Inventor); Diftler, Myron A. (Inventor); Platt, Robert (Inventor); hide

    2013-01-01

    A humanoid robot includes a torso, a pair of arms, two hands, a neck, and a head. The torso extends along a primary axis and presents a pair of shoulders. The pair of arms movably extend from a respective one of the pair of shoulders. Each of the arms has a plurality of arm joints. The neck movably extends from the torso along the primary axis. The neck has at least one neck joint. The head movably extends from the neck along the primary axis. The head has at least one head joint. The shoulders are canted toward one another at a shrug angle that is defined between each of the shoulders such that a workspace is defined between the shoulders.

  7. Simulating cartilage conduction sound to estimate the sound pressure level in the external auditory canal

    NASA Astrophysics Data System (ADS)

    Shimokura, Ryota; Hosoi, Hiroshi; Nishimura, Tadashi; Iwakura, Takashi; Yamanaka, Toshiaki

    2015-01-01

    When the aural cartilage is made to vibrate it generates sound directly into the external auditory canal which can be clearly heard. Although the concept of cartilage conduction can be applied to various speech communication and music industrial devices (e.g. smartphones, music players and hearing aids), the conductive performance of such devices has not yet been defined because the calibration methods are different from those currently used for air and bone conduction. Thus, the aim of this study was to simulate the cartilage conduction sound (CCS) using a head and torso simulator (HATS) and a model of aural cartilage (polyurethane resin pipe) and compare the results with experimental ones. Using the HATS, we found the simulated CCS at frequencies above 2 kHz corresponded to the average measured CCS from seven subjects. Using a model of skull bone and aural cartilage, we found that the simulated CCS at frequencies lower than 1.5 kHz agreed with the measured CCS. Therefore, a combination of these two methods can be used to estimate the CCS with high accuracy.

  8. Evolution of the hominoid vertebral column: The long and the short of it.

    PubMed

    Williams, Scott A; Russo, Gabrielle A

    2015-01-01

    The postcranial axial skeleton exhibits considerable morphological and functional diversity among living primates. Particularly striking are the derived features in hominoids that distinguish them from most other primates and mammals. In contrast to the primitive catarrhine morphotype, which presumably possessed an external (protruding) tail and emphasized more pronograde trunk posture, all living hominoids are characterized by the absence of an external tail and adaptations to orthograde trunk posture. Moreover, modern humans evolved unique vertebral features that satisfy the demands of balancing an upright torso over the hind limbs during habitual terrestrial bipedalism. Our ability to identify the evolutionary timing and understand the functional and phylogenetic significance of these fundamental changes in postcranial axial skeletal anatomy in the hominoid fossil record is key to reconstructing ancestral hominoid patterns and retracing the evolutionary pathways that led to living apes and modern humans. Here, we provide an overview of what is known about evolution of the hominoid vertebral column, focusing on the currently available anatomical evidence of three major transitions: tail loss and adaptations to orthograde posture and bipedal locomotion. © 2015 Wiley Periodicals, Inc.

  9. 49 CFR 572.197 - Abdomen.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... vertical orientation. (4) Push the dummy at the knees and at mid-sternum of the upper torso with just sufficient horizontally oriented force towards the seat back until the back of the upper torso is in contact with the seat back. (5) While maintaining the dummy's position as specified in paragraph (b)(3) and (4...

  10. 49 CFR 572.196 - Thorax without arm.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... orientation. (4) Push the dummy at the knees and at mid-sternum of the upper torso with just sufficient horizontally oriented force towards the seat back until the back of the upper torso is in contact with the seat back. (5) While maintaining the dummy's position as specified in paragraphs (b)(3) and (4) of this...

  11. 49 CFR 572.198 - Pelvis acetabulum.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... the dummy is in vertical orientation. (4) Push the dummy at the knees and at mid-sternum of the upper torso with just sufficient horizontally oriented force towards the seat back until the back of the upper torso is in contact with the seat back. (5) While maintaining the dummy's position as specified in...

  12. 49 CFR 572.195 - Thorax with arm.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... dummy is in vertical orientation. (4) Push the dummy at the knees and at mid-sternum of the upper torso with just sufficient horizontally oriented force towards the seat back until the back of the upper torso is in contact with the seat back. (5) While maintaining the dummy's position as specified in...

  13. 49 CFR 571.210 - Standard No. 210; Seat belt assembly anchorages.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... reference point, shall extend forward from that contact point at an angle with the horizontal of not less... torso belt first contacts the uppermost torso belt anchorage.Seat belt anchorage means any component... line from the seating reference point to the nearest contact point of the belt with the anchorage shall...

  14. 49 CFR 571.213 - Standard No. 213; Child restraint systems.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... the initial pre-test position of the respective knee pivot point, measured along a horizontal line... the head or torso of the appropriate test dummy, specified in S7, when a child restraint system is... (§ 571.225). Torso means the portion of the body of a seated anthropomorphic test dummy, excluding the...

  15. Torso geometry reconstruction and body surface electrode localization using three-dimensional photography.

    PubMed

    Perez-Alday, Erick A; Thomas, Jason A; Kabir, Muammar; Sedaghat, Golriz; Rogovoy, Nichole; van Dam, Eelco; van Dam, Peter; Woodward, William; Fuss, Cristina; Ferencik, Maros; Tereshchenko, Larisa G

    We conducted a prospective clinical study (n=14; 29% female) to assess the accuracy of a three-dimensional (3D) photography-based method of torso geometry reconstruction and body surface electrodes localization. The position of 74 body surface electrocardiographic (ECG) electrodes (diameter 5mm) was defined by two methods: 3D photography, and CT (marker diameter 2mm) or MRI (marker size 10×20mm) imaging. Bland-Altman analysis showed good agreement in X (bias -2.5 [95% limits of agreement (LoA) -19.5 to 14.3] mm), Y (bias -0.1 [95% LoA -14.1 to 13.9] mm), and Z coordinates (bias -0.8 [95% LoA -15.6 to 14.2] mm), as defined by the CT/MRI imaging, and 3D photography. The average Hausdorff distance between the two torso geometry reconstructions was 11.17±3.05mm. Thus, accurate torso geometry reconstruction using 3D photography is feasible. Body surface ECG electrodes coordinates as defined by the CT/MRI imaging, and 3D photography, are in good agreement. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Estimating neuromuscular stimulation within the human torso with Taser stimulus.

    PubMed

    Sun, Hongyu; Webster, John G

    2007-11-07

    Designers of electromuscular incapacitation devices need to know efficacy. Which areas of nerve and muscle are stimulated and are these areas adequate to cause incapacitation? This paper focuses on efficacy, which used a torso-sized finite element model with a mesh of about 5 mm. To estimate the neuromuscular regions stimulated by the Taser X26, calculations of electric current density and field strength values with 1 A inserted into the torso using the Utah 3D mesh were made. Field-times-duration values for given Taser stimulation were calculated. Then the region where the motor nerve was stimulated by the Taser was estimated by using a field-times-duration threshold from Reilly (1998 'Applied Bioelectricity: From Electrical Stimulation to Electropathology ' (New York: Springer)). Neuromuscular stimulation occurred up to about 19 cm away from the darts and included the spinal cord. The current density at the heart for dart separation less than 10 cm was smaller than for larger dart separation. Users of finite element computer models will find information for torso models and their creation, meshing and operation.

  17. Estimating neuromuscular stimulation within the human torso with Taser® stimulus

    NASA Astrophysics Data System (ADS)

    Sun, Hongyu; Webster, John G.

    2007-11-01

    Designers of electromuscular incapacitation devices need to know efficacy. Which areas of nerve and muscle are stimulated and are these areas adequate to cause incapacitation? This paper focuses on efficacy, which used a torso-sized finite element model with a mesh of about 5 mm. To estimate the neuromuscular regions stimulated by the Taser® X26, calculations of electric current density and field strength values with 1 A inserted into the torso using the Utah 3D mesh were made. Field-times-duration values for given Taser stimulation were calculated. Then the region where the motor nerve was stimulated by the Taser was estimated by using a field-times-duration threshold from Reilly (1998 Applied Bioelectricity: From Electrical Stimulation to Electropathology (New York: Springer)). Neuromuscular stimulation occurred up to about 19 cm away from the darts and included the spinal cord. The current density at the heart for dart separation less than 10 cm was smaller than for larger dart separation. Users of finite element computer models will find information for torso models and their creation, meshing and operation.

  18. An analysis of a discrete complex skill using Bernstein's stages of learning.

    PubMed

    Smith, D R; McCabe, D R; Wilkerson, J D

    2001-08-01

    The purpose of this study was to provide quantitative data about changes in coordination after practicing a racquetball forehand drive serve. Novice women (N = 10) were videotaped before and after 10 min. of practicing a racquetball forehand drive serve on Day 1, and after 10-min. practice sessions on consecutive Days 2 through 5. The PEAK5 Motion Measurement System was used to evaluate the following dependent variables: (a) range of motion of the wrist, elbow, upper torso, and pelvis from backswing to ball contact: (b) racket head velocity at ball contact; and (c) coordination. Coordination was evaluated based on analysis of the angular velocity graphs of each performance to assess sequencing and timing of the segmental contributions. Shared positive contribution was assessed between adjacent 2-segment combinations: pelvis-torso and elbow-wrist. A repeated-measures analysis of variance indicated racket velocity, pelvic rotation, and upper torso rotation significantly increased over the 5 days of practice. Although participants increased their pelvic and torso ranges of motion and racket velocity, improvement in coordination was not documented.

  19. The localization of focal heart activity via body surface potential measurements: tests in a heterogeneous torso phantom

    NASA Astrophysics Data System (ADS)

    Wetterling, F.; Liehr, M.; Schimpf, P.; Liu, H.; Haueisen, J.

    2009-09-01

    The non-invasive localization of focal heart activity via body surface potential measurements (BSPM) could greatly benefit the understanding and treatment of arrhythmic heart diseases. However, the in vivo validation of source localization algorithms is rather difficult with currently available measurement techniques. In this study, we used a physical torso phantom composed of different conductive compartments and seven dipoles, which were placed in the anatomical position of the human heart in order to assess the performance of the Recursively Applied and Projected Multiple Signal Classification (RAP-MUSIC) algorithm. Electric potentials were measured on the torso surface for single dipoles with and without further uncorrelated or correlated dipole activity. The localization error averaged 11 ± 5 mm over 22 dipoles, which shows the ability of RAP-MUSIC to distinguish an uncorrelated dipole from surrounding sources activity. For the first time, real computational modelling errors could be included within the validation procedure due to the physically modelled heterogeneities. In conclusion, the introduced heterogeneous torso phantom can be used to validate state-of-the-art algorithms under nearly realistic measurement conditions.

  20. Splenic trauma as an adverse effect of torso-protecting side airbags: biomechanical and case evidence.

    PubMed

    Hallman, Jason J; Brasel, Karen J; Yoganandan, Narayan; Pintar, Frank A

    2009-10-01

    Injury mechanisms from frontal airbags, first identified in anecdotal reports, are now well documented for pediatric, small female, and out-of-position occupants. In contrast, torso side airbags have not yet been consistently associated with specific injury risks in field assessments. To determine possible torso side airbag-related injuries, the present study identified crashes involving side airbags from reports within the CIREN, NASS, and SCI databases. Injury patterns were compared to patterns from lateral crashes in absence of side airbag. Splenic trauma (AIS 3+) was found present in five cases of torso side airbag deployment at lower impact severity (as measured by velocity change and compartment intrusion) than cases of splenic trauma without side airbag. Five additional cases were found to contain similar injury patterns but occurred with greater crash severity. To supplement case analyses, full scale sled tests were conducted with a THOR-NT dummy and cadaveric specimen. Four THOR tests with door- and seat-mounted torso side airbags confirmed that out-of-position (early inflation stage) airbag contact elevated thoracic injury metrics compared to optimal (fully inflated) contact. Out-of-position seat-mounted airbag deployment also produced AIS 3 splenic trauma in the cadaveric specimen. Due to potentially sudden or delayed onset of intraperitoneal hemorrhage and hypovolemic shock following splenic trauma, further biomechanical investigation of this anecdotal evidence is essential to identify injury mechanisms, prevention techniques, and methods for early diagnosis.

  1. Splenic Trauma as an Adverse Effect of Torso-Protecting Side Airbags: Biomechanical and Case Evidence

    PubMed Central

    Hallman, Jason J.; Brasel, Karen J.; Yoganandan, Narayan; Pintar, Frank A.

    2009-01-01

    Injury mechanisms from frontal airbags, first identified in anecdotal reports, are now well documented for pediatric, small female, and out-of-position occupants. In contrast, torso side airbags have not yet been consistently associated with specific injury risks in field assessments. To determine possible torso side airbag-related injuries, the present study identified crashes involving side airbags from reports within the CIREN, NASS, and SCI databases. Injury patterns were compared to patterns from lateral crashes in absence of side airbag. Splenic trauma (AIS 3+) was found present in five cases of torso side airbag deployment at lower impact severity (as measured by velocity change and compartment intrusion) than cases of splenic trauma without side airbag. Five additional cases were found to contain similar injury patterns but occurred with greater crash severity. To supplement case analyses, full scale sled tests were conducted with a THOR-NT dummy and cadaveric specimen. Four THOR tests with door- and seat-mounted torso side airbags confirmed that out-of-position (early inflation stage) airbag contact elevated thoracic injury metrics compared to optimal (fully inflated) contact. Out-of-position seat-mounted airbag deployment also produced AIS 3 splenic trauma in the cadaveric specimen. Due to potentially sudden or delayed onset of intraperitoneal hemorrhage and hypovolemic shock following splenic trauma, further biomechanical investigation of this anecdotal evidence is essential to identify injury mechanisms, prevention techniques, and methods for early diagnosis. PMID:20184829

  2. An eight-week golf-specific exercise program improves physical characteristics, swing mechanics, and golf performance in recreational golfers.

    PubMed

    Lephart, Scott M; Smoliga, James M; Myers, Joseph B; Sell, Timothy C; Tsai, Yung-Shen

    2007-08-01

    The purpose of this study was to determine the effects of an 8-week golf-specific exercise program on physical characteristics, swing mechanics, and golf performance. Fifteen trained male golfers (47.2 +/- 11.4 years, 178.8 +/- 5.8 cm, 86.7 +/- 9.0 kg, and 12.1 +/- 6.4 U.S. Golf Association handicap) were recruited. Trained golfers was defined operationally as golfers who play a round of golf at least 2-3 times per week and practice at the driving range at least 2-3 times per week during the regular golf season. Subjects performed a golf-specific conditioning program 3-4 times per week for 8 weeks during the off-season in order to enhance physical characteristics. Pre- and posttraining testing of participants included assessments of strength (torso, shoulder, and hip), flexibility, balance, swing mechanics, and golf performance. Following training, torso rotational strength and hip abduction strength were improved significantly (p < 0.05). Torso, shoulder, and hip flexibility improved significantly in all flexibility measurements taken (p < 0.05). Balance was improved significantly in 3 of 12 measurements, with the remainder of the variables demonstrating a nonsignificant trend for improvement. The magnitude of upper-torso axial rotation was decreased at the acceleration (p = 0.015) and impact points (p =0.043), and the magnitude of pelvis axial rotation was decreased at the top (p = 0.031) and acceleration points (p = 0.036). Upper-torso axial rotational velocity was increased significantly at the acceleration point of the golf swing (p = 0.009). Subjects increased average club velocity (p = 0.001), ball velocity (p = 0.001), carry distance (p = 0.001), and total distance (p = 0.001). These results indicate that a golf-specific exercise program improves strength, flexibility, and balance in golfers. These improvements result in increased upper-torso axial rotational velocity, which results in increased club head velocity, ball velocity, and driving distance.

  3. Influence of torso and arm positions on chest examinations by electrical impedance tomography.

    PubMed

    Vogt, B; Mendes, L; Chouvarda, I; Perantoni, E; Kaimakamis, E; Becher, T; Weiler, N; Tsara, V; Paiva, R P; Maglaveras, N; Frerichs, I

    2016-06-01

    Electrical impedance tomography (EIT) is increasingly used in patients suffering from respiratory disorders during pulmonary function testing (PFT). The EIT chest examinations often take place simultaneously to conventional PFT during which the patients involuntarily move in order to facilitate their breathing. Since the influence of torso and arm movements on EIT chest examinations is unknown, we studied this effect in 13 healthy subjects (37  ±  4 years, mean age  ±  SD) and 15 patients with obstructive lung diseases (72  ±  8 years) during stable tidal breathing. We carried out the examinations in an upright sitting position with both arms adducted, in a leaning forward position and in an upright sitting position with consecutive right and left arm elevations. We analysed the differences in EIT-derived regional end-expiratory impedance values, tidal impedance variations and their spatial distributions during all successive study phases. Both the torso and the arm movements had a highly significant influence on the end-expiratory impedance values in the healthy subjects (p  =  0.0054 and p  <  0.0001, respectively) and the patients (p  <  0.0001 in both cases). The global tidal impedance variation was affected by the torso, but not the arm movements in both study groups (p  =  0.0447 and p  =  0.0418, respectively). The spatial heterogeneity of the tidal ventilation distribution was slightly influenced by the alteration of the torso position only in the patients (p  =  0.0391). The arm movements did not impact the ventilation distribution in either study group. In summary, the forward torso movement and the arms' abduction exert significant effects on the EIT waveforms during tidal breathing. We recommend strict adherence to the upright sitting position during PFT when EIT is used.

  4. 77 FR 19155 - Federal Motor Vehicle Safety Standards; Seat Belt Assembly Anchorages; Incorporation by Reference

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-30

    ... representative of a human form than the upper torso and pelvic body blocks. As noted in the docketed test reports... anchorage system during compliance tests of anchorage strength. The device represents a human torso and... proposing this amendment because the devices are significantly easier to use than the current body blocks...

  5. Combining Simulated Patients and Simulators: Pilot Study of Hybrid Simulation in Teaching Cardiac Auscultation

    ERIC Educational Resources Information Center

    Friederichs, Hendrik; Weissenstein, Anne; Ligges, Sandra; Möller, David; Becker, Jan C.; Marschall, Bernhard

    2014-01-01

    Auscultation torsos are widely used to teach position-dependent heart sounds and murmurs. To provide a more realistic teaching experience, both whole body auscultation mannequins and torsos have been used in clinical examination skills training at the Medical Faculty of the University of Muenster since the winter term of 2008-2009. This training…

  6. Amygdala volume mediates the relationship between externalizing symptoms and daily smoking in adolescence: A prospective study.

    PubMed

    Cheetham, Ali; Allen, Nicholas B; Whittle, Sarah; Simmons, Julian; Yücel, Murat; Lubman, Dan I

    2018-06-30

    The current study examined amygdala and orbitofrontal cortex (OFC) volumes as mediators of the relationship between externalizing symptoms and daily smoking in adolescence. Externalizing behaviors are among the most robust predictors of adolescent smoking, and there is emerging evidence that volume reductions in the amygdala and OFC are associated with risk for substance misuse as well as aggressive, impulsive, and disinhibited tendencies. Using a prospective longitudinal design, we recruited 109 adolescents who provided data on brain volume and externalizing behaviors at age 12, and on smoking at age 18. Daily smoking at age 18 (n = 27) was predicted by externalizing behaviors (measured by the self-report Child Behavior Checklist, CBCL) as well as smaller right amygdala volumes. Right amygdala volumes mediated the relationship between externalizing symptoms and later smoking. These findings provide important insight into the neurobiological risk factors associated with adolescent smoking, and, more generally, into factors that may be associated with vulnerability to substance use disorders and related psychopathology. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. Optimum location of external markers using feature selection algorithms for real‐time tumor tracking in external‐beam radiotherapy: a virtual phantom study

    PubMed Central

    Nankali, Saber; Miandoab, Payam Samadi; Baghizadeh, Amin

    2016-01-01

    In external‐beam radiotherapy, using external markers is one of the most reliable tools to predict tumor position, in clinical applications. The main challenge in this approach is tumor motion tracking with highest accuracy that depends heavily on external markers location, and this issue is the objective of this study. Four commercially available feature selection algorithms entitled 1) Correlation‐based Feature Selection, 2) Classifier, 3) Principal Components, and 4) Relief were proposed to find optimum location of external markers in combination with two “Genetic” and “Ranker” searching procedures. The performance of these algorithms has been evaluated using four‐dimensional extended cardiac‐torso anthropomorphic phantom. Six tumors in lung, three tumors in liver, and 49 points on the thorax surface were taken into account to simulate internal and external motions, respectively. The root mean square error of an adaptive neuro‐fuzzy inference system (ANFIS) as prediction model was considered as metric for quantitatively evaluating the performance of proposed feature selection algorithms. To do this, the thorax surface region was divided into nine smaller segments and predefined tumors motion was predicted by ANFIS using external motion data of given markers at each small segment, separately. Our comparative results showed that all feature selection algorithms can reasonably select specific external markers from those segments where the root mean square error of the ANFIS model is minimum. Moreover, the performance accuracy of proposed feature selection algorithms was compared, separately. For this, each tumor motion was predicted using motion data of those external markers selected by each feature selection algorithm. Duncan statistical test, followed by F‐test, on final results reflected that all proposed feature selection algorithms have the same performance accuracy for lung tumors. But for liver tumors, a correlation‐based feature selection algorithm, in combination with a genetic search algorithm, proved to yield best performance accuracy for selecting optimum markers. PACS numbers: 87.55.km, 87.56.Fc PMID:26894358

  8. A model based method for recognizing psoas major muscles in torso CT images

    NASA Astrophysics Data System (ADS)

    Kamiya, Naoki; Zhou, Xiangrong; Chen, Huayue; Hara, Takeshi; Yokoyama, Ryujiro; Kanematsu, Masayuki; Hoshi, Hiroaki; Fujita, Hiroshi

    2010-03-01

    In aging societies, it is important to analyze age-related hypokinesia. A psoas major muscle has many important functional capabilities such as capacity of balance and posture control. These functions can be measured by its cross sectional area (CSA), volume, and thickness. However, these values are calculated manually in the clinical situation. The purpose of our study is to propose an automated recognition method of psoas major muscles in X-ray torso CT images. The proposed recognition process involves three steps: 1) determination of anatomical points such as the origin and insertion of the psoas major muscle, 2) generation of a shape model for the psoas major muscle, and 3) recognition of the psoas major muscles by use of the shape model. The model was built using quadratic function, and was fit to the anatomical center line of psoas major muscle. The shape model was generated using 20 CT cases and tested by 20 other CT cases. The applied database consisted of 12 male and 8 female cases from the ages of 40's to 80's. The average value of Jaccard similarity coefficient (JSC) values employed in the evaluation was 0.7. Our experimental results indicated that the proposed method was effective for a volumetric analysis and could be possible to be used for a quantitative measurement of psoas major muscles in CT images.

  9. Kinematics of the Pelvis, Torso, and Lower Limb During Obstacle Negotiation While Under Temporal Constraints.

    PubMed

    Christensen, Jesse C; Wilson, Christopher R; Merryweather, Andrew S; Foreman, K Bo

    2017-04-01

    Biomechanics of unobstructed locomotion consists of synchronized complex movements of the pelvis, torso, and lower limbs. These movement patterns become more complex as individuals encounter obstacles or negotiate uneven terrain. To date, limited research has explored how specifically the pelvis, torso, and lower limb segments relate to obstacle negotiation of varying sized objects combined with temporal constraints to perform the task. Understanding pelvis and adjoining segment movements during object negotiation will provide necessary information in identifying abnormal mechanics and potential fall risk characteristics in balance compromised patient populations. In this prospective cohort study, we aimed to compare pelvic, torso, and lower limb kinematics during unobstructed locomotion with obstacle negotiation of varying heights. Ten healthy young adults (7 females and 3 males, mean age 28.4 ± 4.1 years, mean body mass index 22.5 ± 3.6 kg/m 2 ) enrolled in this study. Analysis of within-subject differences revealed a significant increase in sagittal (posterior tilt) and frontal (ipsilateral hike) plane pelvic angular displacement and higher sagittal plane posterior torso lean angular displacement with increased obstacle height. Furthermore, both sagittal plane hip and knee maximum joint flexion were significantly higher with increasing heights of the obstacles during negotiation. These data provide insight on segment mechanics within a non-mobility-impaired population; therefore, providing a baseline to understand the kinematic demands necessary for safe and effective gait in mobility-compromised populations. Anat Rec, 300:732-738, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  10. Pancreatic Cancer Detection Consortium (PCDC) | Division of Cancer Prevention

    Cancer.gov

    [[{"fid":"2256","view_mode":"default","fields":{"format":"default","field_file_image_alt_text[und][0][value]":"A 3-dimensional image of a human torso highlighting the pancreas.","field_file_image_title_text[und][0][value]":false},"type":"media","field_deltas":{"1":{"format":"default","field_file_image_alt_text[und][0][value]":"A 3-dimensional image of a human torso

  11. Are Torsos the Basis for Infants' Categorization of Cats Versus Dogs? A Reply to Vidic and Haaf (2004)

    ERIC Educational Resources Information Center

    Quinn, Paul C.

    2005-01-01

    Vidic and Haaf (2004) questioned the idea that infants use head information to categorize cats as distinct from dogs (Quinn & Eimas, 1996) and argued instead that the torso region is important. However, only null results were observed in the critical test comparisons between modified and unmodified stimuli. In addition, a priori preferences for…

  12. Detailed Anatomical and Electrophysiological Models of Human Atria and Torso for the Simulation of Atrial Activation

    PubMed Central

    Ferrer, Ana; Sebastián, Rafael; Sánchez-Quintana, Damián; Rodríguez, José F.; Godoy, Eduardo J.; Martínez, Laura; Saiz, Javier

    2015-01-01

    Atrial arrhythmias, and specifically atrial fibrillation (AF), induce rapid and irregular activation patterns that appear on the torso surface as abnormal P-waves in electrocardiograms and body surface potential maps (BSPM). In recent years both P-waves and the BSPM have been used to identify the mechanisms underlying AF, such as localizing ectopic foci or high-frequency rotors. However, the relationship between the activation of the different areas of the atria and the characteristics of the BSPM and P-wave signals are still far from being completely understood. In this work we developed a multi-scale framework, which combines a highly-detailed 3D atrial model and a torso model to study the relationship between atrial activation and surface signals in sinus rhythm. Using this multi scale model, it was revealed that the best places for recording P-waves are the frontal upper right and the frontal and rear left quadrants of the torso. Our results also suggest that only nine regions (of the twenty-one structures in which the atrial surface was divided) make a significant contribution to the BSPM and determine the main P-wave characteristics. PMID:26523732

  13. Material Models for the Human Torso Finite Element Model

    DTIC Science & Technology

    2018-04-04

    material characterizations drawn from current literature. Biofidelity of the ARL torso was determined by comparing peak force, force-displacement, peak...Flesh simulation. The soft tissue mesh in the upper neck was highly distorted at 21.2 ms (right) compared to the original mesh (left...a realistic response with results comparable to physical experiments to support future efforts to evaluate BABT. 2. Methods 2.1 Review of

  14. Classification of male lower torso for underwear design

    NASA Astrophysics Data System (ADS)

    Cheng, Z.; Kuzmichev, V. E.

    2017-10-01

    By means of scanning technology we have got new information about the morphology of male bodies and have redistricted the classification of men’s underwear by adopting one to consumer demands. To build the new classification in accordance with male body characteristic factors of lower torso, we make the method of underwear designing which allow to get the accurate and convenience for consumers products.

  15. Current management of penetrating torso trauma: nontherapeutic is not good enough anymore.

    PubMed

    Ball, Chad G

    2014-04-01

    A highly organized approach to the evaluation and treatment of penetrating torso injuries based on regional anatomy provides rapid diagnostic and therapeutic consistency. It also minimizes delays in diagnosis, missed injuries and nontherapeutic laparotomies. This review discusses an optimal sequence of structured rapid assessments that allow the clinician to rapidly proceed to gold standard therapies with a minimal risk of associated morbidity.

  16. Effects of underestimating the kinematics of trunk rotation on simultaneous reaching movements: predictions of a biomechanical model

    PubMed Central

    2013-01-01

    Background Rotation of the torso while reaching produces torques (e.g., Coriolis torque) that deviate the arm from its planned trajectory. To ensure an accurate reaching movement, the brain may take these perturbing torques into account during movement planning or, alternatively, it may correct hand trajectory during movement execution. Irrespective of the process selected, it is expected that an underestimation of trunk rotation would likely induce inaccurate shoulder and elbow torques, resulting in hand deviation. Nonetheless, it is still undetermined to what extent a small error in the perception of trunk rotations, translating into an inappropriate selection of motor commands, would affect reaching accuracy. Methods To investigate, we adapted a biomechanical model (J Neurophysiol 89: 276-289, 2003) to predict the consequences of underestimating trunk rotations on right hand reaching movements performed during either clockwise or counter clockwise torso rotations. Results The results revealed that regardless of the degree to which the torso rotation was underestimated, the amplitude of hand deviation was much larger for counter clockwise rotations than for clockwise rotations. This was attributed to the fact that the Coriolis and centripetal joint torques were acting in the same direction during counter clockwise rotation yet in opposite directions during clockwise rotations, effectively cancelling each other out. Conclusions These findings suggest that in order to anticipate and compensate for the interaction torques generated during torso rotation while reaching, the brain must have an accurate prediction of torso rotation kinematics. The present study proposes that when designing upper limb prostheses controllers, adding a sensor to monitor trunk kinematics may improve prostheses control and performance. PMID:23758968

  17. Feasibility study of a new RF coil design for prostate MRI

    NASA Astrophysics Data System (ADS)

    Ha, Seunghoon; Roeck, Werner W.; Cho, Jaedu; Nalcioglu, Orhan

    2014-09-01

    The combined use of a torso-pelvic RF array coil and endorectal RF coil is the current state-of-the-art in prostate MRI. The endorectal coil provides high detection sensitivity to acquire high-spatial resolution images and spectroscopic data, while the torso-pelvic coil provides large coverage to assess pelvic lymph nodes and pelvic bones for metastatic disease. However, the use of an endorectal coil is an invasive procedure that presents difficulties for both patients and technicians. In this study, we propose a novel non-invasive RF coil design that can provide both image signal to noise ratio and field of view coverage comparable to the combined torso-pelvic and endorectal coil configuration. A prototype coil was constructed and tested using a pelvic phantom. The results demonstrate that this new design is a viable alternative for prostate MRI

  18. Current management of penetrating torso trauma: nontherapeutic is not good enough anymore

    PubMed Central

    Ball, Chad G.

    2014-01-01

    A highly organized approach to the evaluation and treatment of penetrating torso injuries based on regional anatomy provides rapid diagnostic and therapeutic consistency. It also minimizes delays in diagnosis, missed injuries and nontherapeutic laparotomies. This review discusses an optimal sequence of structured rapid assessments that allow the clinician to rapidly proceed to gold standard therapies with a minimal risk of associated morbidity. PMID:24666458

  19. Suicide bombing attacks: Can external signs predict internal injuries?

    PubMed

    Almogy, Gidon; Mintz, Yoav; Zamir, Gideon; Bdolah-Abram, Tali; Elazary, Ram; Dotan, Livnat; Faruga, Mohammed; Rivkind, Avraham I

    2006-04-01

    To report the distribution and types of injuries in victims of suicide bombing attacks and to identify external signs that would guide triage and initial management. There is a need for information on the degree to which external injuries indicate internal injuries requiring emergency triage. The medical charts and the trauma registry database of all patients who were admitted to the Hadassah Hospital in Jerusalem from August 2001 to August 2004 following a suicide bombing attack were reviewed and analyzed for injury characteristics, number of body areas injured, presence of blast lung injury (BLI), and need for therapeutic laparotomy. Logistic analysis was performed to identify predictors of BLI and intra-abdominal injury. The study population consisted of 154 patients who were injured as a result of 17 attacks. Twenty-eight patients suffered from BLI (18.2%) and 13 patients (8.4%) underwent therapeutic laparotomy. Patients with penetrating head injury and those with > or =4 body areas injured were significantly more likely to suffer from BLI (odds ratio, 3.47 and 4.12, respectively, P < 0.05). Patients with penetrating torso injury and those with > or =4 body areas injured were significantly more likely to suffer from intra-abdominal injury (odds ratio, 22.27 and 4.89, respectively, P < 0.05). Easily recognizable external signs of trauma can be used to predict the occurrence of BLI and intra-abdominal injury. The importance of these signs needs to be incorporated into triage protocols and used to direct victims to the appropriate level of care both from the scene and in the hospital.

  20. Do the SRS-22 self-image and mental health domain scores reflect the degree of asymmetry of the back in adolescent idiopathic scoliosis?

    PubMed

    Cheshire, James; Gardner, Adrian; Berryman, Fiona; Pynsent, Paul

    2017-01-01

    Patient-reported outcomes are becoming increasingly recognised in the management of patients with adolescent idiopathic scoliosis (AIS). Integrated Shape Imaging System 2 (ISIS2) surface topography is a validated tool to assess AIS. Previous studies have failed to demonstrate strong correlations between AIS and patient-reported outcomes highlighting the need for additional objective surface parameters to define the deformities associated with AIS. The aim of this study was to examine whether the Scoliosis Research Society-22 (SRS-22) outcome questionnaire reflects the degree of measurable external asymmetry of the back in AIS and thus is a measure of patient outcome for external appearance. A total of 102 pre-operative AIS patients were identified retrospectively. Objective parameters were measured using ISIS2 surface topography. The associations between these parameters and the self-image and mental health domains of the SRS-22 questionnaire were investigated using correlation coefficients. All correlations between the parameters of asymmetry and SRS-22 self-image score were of weak strength. Similarly, all correlations between the parameters of asymmetry and SRS-22 mental health score were of weak strength. The SRS-22 mental health and self-image domains correlate poorly with external measures of deformity. This demonstrates that the assessment of mental health and self-image by the SRS-22 has little to do with external torso shape. Whilst the SRS-22 assesses the patient as a whole, it provides little information about objective measures of deformity over which a surgeon has control.

  1. Preschool Externalizing Behavior Predicts Gender-Specific Variation in Adolescent Neural Structure

    PubMed Central

    Caldwell, Jessica Z. K.; Armstrong, Jeffrey M.; Hanson, Jamie L.; Sutterer, Matthew J.; Stodola, Diane E.; Koenigs, Michael; Kalin, Ned H.

    2015-01-01

    Dysfunction in the prefrontal cortex, amygdala, and hippocampus is believed to underlie the development of much psychopathology. However, to date only limited longitudinal data relate early behavior with neural structure later in life. Our objective was to examine the relationship of early life externalizing behavior with adolescent brain structure. We report here the first longitudinal study linking externalizing behavior during preschool to brain structure during adolescence. We examined the relationship of preschool externalizing behavior with amygdala, hippocampus, and prefrontal cortex volumes at age 15 years in a community sample of 76 adolescents followed longitudinally since their mothers’ pregnancy. A significant gender by externalizing behavior interaction revealed that males—but not females—with greater early childhood externalizing behavior had smaller amygdala volumes at adolescence (t = 2.33, p = .023). No significant results were found for the hippocampus or the prefrontal cortex. Greater early externalizing behavior also related to smaller volume of a cluster including the angular gyrus and tempoparietal junction across genders. Results were not attributable to the impact of preschool anxiety, preschool maternal stress, school-age internalizing or externalizing behaviors, or adolescent substance use. These findings demonstrate a novel, gender-specific relationship between early-childhood externalizing behavior and adolescent amygdala volume, as well as a cross-gender result for the angular gyrus and tempoparietal junction. PMID:25658357

  2. The Audible Human Project: Modeling Sound Transmission in the Lungs and Torso

    NASA Astrophysics Data System (ADS)

    Dai, Zoujun

    Auscultation has been used qualitatively by physicians for hundreds of years to aid in the monitoring and diagnosis of pulmonary diseases. Alterations in the structure and function of the pulmonary system that occur in disease or injury often give rise to measurable changes in lung sound production and transmission. Numerous acoustic measurements have revealed the differences of breath sounds and transmitted sounds in the lung under normal and pathological conditions. Compared to the extensive cataloging of lung sound measurements, the mechanism of sound transmission in the pulmonary system and how it changes with alterations of lung structural and material properties has received less attention. A better understanding of sound transmission and how it is altered by injury and disease might improve interpretation of lung sound measurements, including new lung imaging modalities that are based on an array measurement of the acoustic field on the torso surface via contact sensors or are based on a 3-dimensional measurement of the acoustic field throughout the lungs and torso using magnetic resonance elastography. A long-term goal of the Audible Human Project (AHP ) is to develop a computational acoustic model that would accurately simulate generation, transmission and noninvasive measurement of sound and vibration within the pulmonary system and torso caused by both internal (e.g. respiratory function) and external (e.g. palpation) sources. The goals of this dissertation research, fitting within the scope of the AHP, are to develop specific improved theoretical understandings, computational algorithms and experimental methods aimed at transmission and measurement. The research objectives undertaken in this dissertation are as follows. (1) Improve theoretical modeling and experimental identification of viscoelasticity in soft biological tissues. (2) Develop a poroviscoelastic model for lung tissue vibroacoustics. (3) Improve lung airway acoustics modeling and its coupling to the lung parenchyma; and (4) Develop improved techniques in array acoustic measurement on the torso surface of sound transmitted through the pulmonary system and torso. Tissue Viscoelasticity. Two experimental identification approaches of shear viscoelasticity were used. The first approach is to directly estimate the frequency-dependent surface wave speed and then to optimize the coefficients in an assumed viscoelastic model type. The second approach is to measure the complex-valued frequency response function (FRF) between the excitation location and points at known radial distances. The FRF has embedded in it frequency-dependent information about both surface wave phase speed and attenuation that can be used to directly estimate the complex shear modulus. The coefficients in an assumed viscoelastic tissue model type can then be optimized. Poroviscoelasticity Model for Lung Vibro-acoustics. A poroviscoelastic model based on Biot theory of wave propagation in porous media was used for compression waves in the lungs. This model predicts a fast compression wave speed close to the one predicted by the effective medium theory at low frequencies and an additional slow compression wave due to the out of phase motion of the air and the lung parenchyma. Both compression wave speeds vary with frequency. The fast compression wave speed and attenuation were measured on an excised pig lung under two different transpulmonary pressures. Good agreement was achieved between the experimental observation and theoretical predictions. Sound Transmission in Airways and Coupling to Lung Parenchyma. A computer generated airway tree was simplified to 255 segments and integrated into the lung geometry from the Visible Human Male for numerical simulations. Acoustic impedance boundary conditions were applied at the ends of the terminal segments to represent the unmodeled downstream airway segments. Experiments were also carried out on a preserved pig lung and similar trends of lung surface velocity distribution were observed between the experiments and simulations. This approach provides a feasible way of simplifying the airway tree and greatly reduces the computation time. Acoustic Measurements of Sound Transmission in Human Subjects. Scanning laser Doppler vibrometry (SLDV) was used as a gold standard for transmitted sound measurements on a human subject. A low cost piezodisk sensor array was also constructed as an alternative to SLDV. The advantages and disadvantages of each technique are discussed.

  3. Injury Pattern and Mortality of Noncompressible Torso Hemorrhage in UK Combat Casualties

    DTIC Science & Technology

    2013-08-01

    body disruption (5.1%), and multiple-organ failure (4.0%). On multivariate analysis, major arterial and pulmonary hilar injury are most lethal with odds...death. Major arterial and pulmonary hilar injuries are independent predictors of mortality. (J Trauma Acute Care Surg. 2013;75: S263YS268. Copyright...physiologic or procedural indices of shock.8 Anatomic refers to those injuries to a named torso vessel, pulmonary injury (massive hemothorax or hilar

  4. Noncompressible Torso Hemorrhage: A Review with Contemporary Definitions and Management Strategies

    DTIC Science & Technology

    2012-01-01

    Criteria 1. Thoracic cavity (including lung ) 2. Solid organ injury grade 4 (liver, kidney, spleen) Hemorrhagic shocka; or need for immediate operation 3...resuscitation and warming in the intensive care unit. DCS is an extreme surgical strategy that carries a risk of infection; intra-abdominal abscess ...depending on location. Injury to the periphery Noncompressible Torso Hemorrhage 849 of the lung can be stapled off in a nonanatomic fashion using a linear

  5. Safety harness

    DOEpatents

    Gunter, Larry W.

    1993-01-01

    A safety harness to be worn by a worker, especially a worker wearing a plastic suit thereunder for protection in a radioactive or chemically hostile environment, which safety harness comprises a torso surrounding portion with at least one horizontal strap for adjustably securing the harness about the torso, two vertical shoulder straps with rings just forward of the of the peak of the shoulders for attaching a life-line and a pair of adjustable leg supporting straps releasibly attachable to the torso surrounding portion. In the event of a fall, the weight of the worker, when his fall is broken and he is suspended from the rings with his body angled slightly back and chest up, will be borne by the portion of the leg straps behind his buttocks rather than between his legs. Furthermore, the supporting straps do not restrict the air supplied through hoses into his suit when so suspended.

  6. Predicting significant torso trauma.

    PubMed

    Nirula, Ram; Talmor, Daniel; Brasel, Karen

    2005-07-01

    Identification of motor vehicle crash (MVC) characteristics associated with thoracoabdominal injury would advance the development of automatic crash notification systems (ACNS) by improving triage and response times. Our objective was to determine the relationships between MVC characteristics and thoracoabdominal trauma to develop a torso injury probability model. Drivers involved in crashes from 1993 to 2001 within the National Automotive Sampling System were reviewed. Relationships between torso injury and MVC characteristics were assessed using multivariate logistic regression. Receiver operating characteristic curves were used to compare the model to current ACNS models. There were a total of 56,466 drivers. Age, ejection, braking, avoidance, velocity, restraints, passenger-side impact, rollover, and vehicle weight and type were associated with injury (p < 0.05). The area under the receiver operating characteristic curve (83.9) was significantly greater than current ACNS models. We have developed a thoracoabdominal injury probability model that may improve patient triage when used with ACNS.

  7. Labyrinth and cerebral-spinal fluid pressure changes in guinea pigs and monkeys during simulated zero G

    NASA Technical Reports Server (NTRS)

    Parker, D. E.

    1977-01-01

    This study was undertaken to explore the hypothesis that shifts of body fluids from the legs and torso toward the head contribute to the motion sickness experienced by astronauts and cosmonauts. The shifts in body fluids observed during zero-G exposure were simulated by elevating guinea pigs' and monkeys' torsos and hindquarters. Cerebral-spinal fluid pressure was recorded from a transducer located in a brain ventricle; labyrinth fluid pressure was recorded from a pipette cemented in a hole in a semicircular canal. An anticipated divergence in cerebral-spinal fluid pressure and labyrinth fluid pressure during torso elevation was not observed. The results of this study do not support a fluid shift mechanism of zero-G-induced motion sickness. However, a more complete test of the fluid shift mechanism would be obtained if endolymph and perilymph pressure changes were determined separately; we have been unable to perform this test to date.

  8. Retroperitoneal sarcoma (RPS) high risk gross tumor volume boost (HR GTV boost) contour delineation agreement among NRG sarcoma radiation and surgical oncologists.

    PubMed

    Baldini, Elizabeth H; Bosch, Walter; Kane, John M; Abrams, Ross A; Salerno, Kilian E; Deville, Curtiland; Raut, Chandrajit P; Petersen, Ivy A; Chen, Yen-Lin; Mullen, John T; Millikan, Keith W; Karakousis, Giorgos; Kendrick, Michael L; DeLaney, Thomas F; Wang, Dian

    2015-09-01

    Curative intent management of retroperitoneal sarcoma (RPS) requires gross total resection. Preoperative radiotherapy (RT) often is used as an adjuvant to surgery, but recurrence rates remain high. To enhance RT efficacy with acceptable tolerance, there is interest in delivering "boost doses" of RT to high-risk areas of gross tumor volume (HR GTV) judged to be at risk for positive resection margins. We sought to evaluate variability in HR GTV boost target volume delineation among collaborating sarcoma radiation and surgical oncologist teams. Radiation planning CT scans for three cases of RPS were distributed to seven paired radiation and surgical oncologist teams at six institutions. Teams contoured HR GTV boost volumes for each case. Analysis of contour agreement was performed using the simultaneous truth and performance level estimation (STAPLE) algorithm and kappa statistics. HRGTV boost volume contour agreement between the seven teams was "substantial" or "moderate" for all cases. Agreement was best on the torso wall posteriorly (abutting posterior chest abdominal wall) and medially (abutting ipsilateral para-vertebral space and great vessels). Contours varied more significantly abutting visceral organs due to differing surgical opinions regarding planned partial organ resection. Agreement of RPS HRGTV boost volumes between sarcoma radiation and surgical oncologist teams was substantial to moderate. Differences were most striking in regions abutting visceral organs, highlighting the importance of collaboration between the radiation and surgical oncologist for "individualized" target delineation on the basis of areas deemed at risk and planned resection.

  9. Conformal Microwave Array (CMA) Applicators for Hyperthermia of Diffuse Chestwall Recurrence

    PubMed Central

    Stauffer, Paul R.; Maccarini, Paolo; Arunachalam, Kavitha; Craciunescu, Oana; Diederich, Chris; Juang, Titania; Rossetto, Francesca; Schlorff, Jaime; Milligan, Andrew; Hsu, Joe; Sneed, Penny; Vujaskovic, Zeljko

    2010-01-01

    Purpose This article summarizes the evolution of microwave array applicators for heating large area chestwall disease as an adjuvant to external beam radiation, systemic chemotherapy, and potentially simultaneous brachytherapy. Methods Current devices used for thermotherapy of chestwall recurrence are reviewed. The largest conformal array applicator to date is evaluated in four studies: i) ability to conform to the torso is demonstrated with a CT scan of a torso phantom and MR scan of the conformal waterbolus component on a mastectomy patient; ii) Specific Absorption Rate (SAR) and temperature distributions are calculated with electromagnetic and thermal simulation software for a mastectomy patient; iii). SAR patterns are measured with a scanning SAR probe in liquid muscle phantom for a buried coplanar waveguide CMA; and iv) heating patterns and patient tolerance of CMA applicators are characterized in a clinical pilot study with 13 patients. Results CT and MR scans demonstrate excellent conformity of CMA applicators to contoured anatomy. Simulations demonstrate effective control of heating over contoured anatomy. Measurements confirm effective coverage of large treatment areas with no gaps. In 42 hyperthermia treatments, CMA applicators provided well-tolerated effective heating of up to 500cm2 regions, achieving target temperatures of Tmin=41.4±0.7°C, T90=42.1±0.6°C, Tave=42.8±0.6°C, and Tmax=44.3±0.8°C as measured in an average of 90 points per treatment. Summary The CMA applicator is an effective thermal therapy device for heating large-area superficial disease such as diffuse chestwall recurrence. It is able to cover over three times the treatment area of conventional hyperthermia devices while conforming to typical body contours. PMID:20849262

  10. Protective supplied breathing air garment

    DOEpatents

    Childers, Edward L.; von Hortenau, Erik F.

    1984-07-10

    A breathing air garment for isolating a wearer from hostile environments containing toxins or irritants includes a suit and a separate head protective enclosure or hood engaging a suit collar in sealing attachment. The hood and suit collar are cylindrically shaped and dimensioned to enable the wearer to withdraw his hands from the suit sleeves to perform manual tasks within the hood interior. Breathing air is supplied from an external air line with an air delivery hose attached to the hood interior. The hose feeds air into an annular halo-like fiber-filled plenum having spaced discharge orifices attached to the hood top wall. A plurality of air exhaust/check valves located at the suit extremities cooperate with the hood air delivery system to provide a cooling flow of circulating air from the hood throughout the suit interior. A suit entry seal provided on the suit rear torso panel permits access into the suit and is sealed with an adhesive sealing flap.

  11. Animal Exposure During Burn Tests

    NASA Technical Reports Server (NTRS)

    Gaume, J. G.

    1978-01-01

    An animal exposure test system (AETS) was designed and fabricated for the purpose of collecting physiological and environmental (temperature) data from animal subjects exposed to combustion gases in large scale fire tests. The AETS consisted of an open wire mesh, two-compartment cage, one containing an exercise wheel for small rodents, and the other containing one rat instrumented externally for electrocardiogram (ECG) and respiration. Cage temperature is measured by a thermistor located in the upper portion of the rat compartment. Animal activity is monitored by the ECG and the records indicate an increase in EMG (electromyograph) noise super-imposed by the increased activity of the torso musculature. Examples of the recordings are presented and discussed as to their significance regarding toxicity of fire gases and specific events occurring during the test. The AETS was shown to be a useful tool in screening materials for the relative toxicity of their outgassing products during pyrolysis and combustion.

  12. The Epidemiology of Noncompressible Torso Hemorrhage in the Wars in Iraq and Afghanistan

    DTIC Science & Technology

    2013-03-01

    torso vascular or pulmonary hemorrhage. Recently, Zonies and Eastridge20 reported 10 years of wartime splenic trauma man- agement with a series of 393...benchmark. J Vasc Surg. 2012;56:728Y736. 20. Zonies D, Eastridge B. Combat management of splenic injury: trends during a decade of conflict. J Trauma ...is the leading cause of potentially survivable trauma in the battlefield and has re- cently been defined using anatomic and physiologic criteria

  13. Investigation of Aircrew Protection During Emergency Escape at Dynamic Pressures up to 1600 Q.

    DTIC Science & Technology

    1982-05-01

    Speed Ejections 14 4 Torso Airflow Stagnation Fence Arm Restraints 16 5 Upper Torso Support Restraint Garment 21 6 Multiaxial Pelvis Restraint 22 7...aircraft. Designs, such as the pelvis and leg elevating (PALE) seats, fixed reclined seats, or pressurized vests, are viable concepts for high sustained...final comment on direct energy transfer from the lower legs to the ai rmass involves aerodynamic asymmetry of the booted foot. Such asymmetry could lead

  14. 49 CFR 571.208a - Optional test procedures for vehicles manufactured between January 27, 2004 and August 31, 2004.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... S16.3.3.1.9 and S16.3.3.1.10. S16.3.5.4 Remove all slack from the lap belt. Pull the upper torso... device, introduce the maximum amount of slack into the upper torso belt that is recommended by the..., place the Type 2 manual belt around the test dummy and fasten the latch. Remove all slack from the lap...

  15. Study on highway transportation greenhouse effect external cost estimation in China

    NASA Astrophysics Data System (ADS)

    Chu, Chunchao; Pan, Fengming

    2017-03-01

    This paper focuses on estimating highway transportation greenhouse gas emission volume and greenhouse gas external cost in China. At first, composition and characteristics of greenhouse gases were analysed about highway transportation emissions. Secondly, an improved model of emission volume was presented on basis of highway transportation energy consumption, which may be calculated by virtue of main affecting factors such as the annual average operation miles of each type of the motor vehicles and the unit consumption level. the model of emission volume was constructed which considered not only the availability of energy consumption statistics of highway transportation but also the greenhouse gas emission factors of various fuel types issued by IPCC. Finally, the external cost estimation model was established about highway transportation greenhouse gas emission which combined emission volume with the unit external cost of CO2 emissions. An example was executed to confirm presented model which ranged from 2011 to 2015 Year in China. The calculated result shows that the highway transportation total emission volume and greenhouse gas external cost are growing up, but the unit turnover external cost is steadily declining. On the whole overall, the situation is still grim about highway transportation greenhouse gas emission, and the green transportation strategy should be put into effect as soon as possible.

  16. Externalizing personality traits, empathy, and gray matter volume in healthy young drinkers

    PubMed Central

    Charpentier, Judith; Dzemidzic, Mario; West, John; Oberlin, Brandon G.; Eiler, William J.A.; Saykin, Andrew J.; Kareken, David A.

    2016-01-01

    Externalizing psychopathology has been linked to prefrontal abnormalities. While clinically diagnosed subjects show altered frontal gray matter, it is unknown if similar deficits relate to externalizing traits in non-clinical populations. We used voxel-based morphometry (VBM) to retrospectively analyze the cerebral gray matter volume of 176 young adult social to heavy drinkers (mean age= 24.0 ± 2.9, male= 83.5%) from studies of alcoholism risk. We hypothesized that prefrontal gray matter volume and externalizing traits would be correlated. Externalizing personality trait components— Boredom Susceptibility-Impulsivity (BS/IMP) and Empathy/Low Antisocial Behaviors (EMP/LASB)— were tested for correlations with gray matter partial volume estimates (gmPVE). Significantly large clusters (pFWE < 0.05, family-wise whole-brain corrected) of gmPVE correlated with EMP/LASB in dorsolateral and medial prefrontal regions, and in occipital cortex. BS/IMP did not correlate with gmPVE, but one scale of impulsivity (Eysenck I7) correlated positively with bilateral inferior frontal/orbitofrontal, and anterior insula gmPVE. In this large sample of community-dwelling young adults, antisocial behavior/low empathy corresponded with reduced prefrontal and occipital gray matter, while impulsivity correlated with increased inferior frontal and anterior insula cortical volume. These findings add to a literature indicating that externalizing personality features involve altered frontal architecture. PMID:26778367

  17. Evolution of a Multidisciplinary Clinical Pathway for the Management of Unstable Patients With Pelvic Fractures

    PubMed Central

    Biffl, Walter L.; Smith, Wade R.; Moore, Ernest E.; Gonzalez, Ricardo J.; Morgan, Steven J.; Hennessey, Theresa; Offner, Patrick J.; Ray, Charles E.; Franciose, Reginald J.; Burch, Jon M.

    2001-01-01

    Objective To determine whether the evolution of the authors’ clinical pathway for the treatment of hemodynamically compromised patients with pelvic fractures was associated with improved patient outcome. Summary Background Data Hemodynamically compromised patients with pelvic fractures present a complex challenge. The multidisciplinary trauma team must control hemorrhage, restore hemodynamics, and rapidly identify and treat associated life-threatening injuries. The authors developed a clinical pathway consisting of five primary elements: immediate trauma attending surgeon’s presence in the emergency department, early simultaneous transfusion of blood and coagulation factors, prompt diagnosis and management of associated life-threatening injuries, stabilization of the pelvic girdle, and timely insinuation of pelvic angiography and embolization. The addition of two orthopedic pelvic fracture specialists led to a revision of the pathway, emphasizing immediate emergency department presence of the orthopedic trauma attending to provide joint decision making with the trauma surgeon, closing the pelvic volume in the emergency department, and using alternatives to traditional external fixation devices. Methods Using trauma registry and blood bank records, the authors identified pelvic fracture patients receiving blood transfusions in the emergency department. They analyzed patients treated before versus after the May 1998 revision of the clinical pathway. Results A higher proportion of patients in the late period had blood pressure less than 90 mmHg (52% vs. 35%). In the late period, diagnostic peritoneal lavage was phased out in favor of torso ultrasound as a primary triage tool, and pelvic binding and C-clamp application largely replaced traditional external fixation devices. The overall death rate decreased from 31% in the early period to 15% in the later period, as did the rate of deaths from exsanguination (9% to 1%), multiple organ failure (12% to 1%), and death within 24 hours (16% to 5%). Conclusions The evolution of a multidisciplinary clinical pathway, coordinating the resources of a level 1 trauma center and directed by joint decision making between trauma surgeons and orthopedic traumatologists, has resulted in improved patient survival. The primary benefits appear to be in reducing early deaths from exsanguination and late deaths from multiple organ failure. PMID:11407336

  18. Spatial-temporal filter effect in a computer model study of ventricular fibrillation.

    PubMed

    Nowak, Claudia N; Fischer, Gerald; Wieser, Leonhard; Tilg, Bernhard; Neurauter, Andreas; Strohmenger, Hans U

    2008-08-01

    Prediction of countershock success from ventricular fibrillation (VF) ECG is a major challenge in critical care medicine. Recent findings indicate that stable, high frequency mother rotors are one possible mechanism maintaining VF. A computer model study was performed to investigate how epicardiac sources are reflected in the ECG. In the cardiac tissues of two computer models - a model with cubic geometry and a simplified torso model with a left ventricle - a mother rotor was induced by increasing the potassium rectifier current. On the epicardium, the dominant frequency (DF) map revealed a constant DF of 23 Hz (cubic model) and 24.4 Hz (torso model) in the region of the mother rotor, respectively. A sharp drop of frequency (3-18 Hz in the cubic model and 12.4-18 Hz in the torso model) occurred in the surrounding epicardial tissue of chaotic fibrillatory conduction. While no organized pattern was observable on the body surface of the cubic model, the mother rotor frequency can be identified in the anterior surface of the torso model because of the chosen position of the mother rotor in the ventricle (shortest distance to the body surface). Nevertheless, the DFs were damped on the body surfaces of both models (4.6-8.5 Hz in the cubic model and 14.4-16.4 Hz in the torso model). Thus, it was shown in this computer model study that wave propagation transforms the spatial low pass filtering of the thorax into a temporal low pass. In contrast to the resistive-capacitive low pass filter formed by the tissue, this spatial-temporal low pass filter becomes effective at low frequencies (tens of Hertz). This effect damps the high frequency components arising from the heart and it hampers a direct observation of rapid, organized sources of VF in the ECGs, when in an emergency case an artifact-free recording is not possible.

  19. Assessing behind armor blunt trauma (BABT) under NIJ standard-0101.04 conditions using human torso models.

    PubMed

    Merkle, Andrew C; Ward, Emily E; O'Connor, James V; Roberts, Jack C

    2008-06-01

    Although soft armor vests serve to prevent penetrating wounds and dissipate impact energy, the potential of nonpenetrating injury to the thorax, termed behind armor blunt trauma, does exist. Currently, the ballistic resistance of personal body armor is determined by impacting a soft armor vest over a clay backing and measuring the resulting clay deformation as specified in National Institute of Justice (NIJ) Standard-0101.04. This research effort evaluated the efficacy of a physical Human Surrogate Torso Model (HSTM) as a device for determining thoracic response when exposed to impact conditions specified in the NIJ Standard. The HSTM was subjected to a series of ballistic impacts over the sternum and stomach. The pressure waves propagating through the torso were measured with sensors installed in the organs. A previously developed Human Torso Finite Element Model (HTFEM) was used to analyze the amount of tissue displacement during impact and compared with the amount of clay deformation predicted by a validated finite element model. All experiments and simulations were conducted at NIJ Standard test conditions. When normalized by the response at the lowest threat level (Level I), the clay deformations for the higher levels are relatively constant and range from 2.3 to 2.7 times that of the base threat level. However, the pressures in the HSTM increase with each test level and range from three to seven times greater than Level I depending on the organ. The results demonstrate the abilities of the HSTM to discriminate between threat levels, impact conditions, and impact locations. The HTFEM and HSTM are capable of realizing pressure and displacement differences because of the level of protection, surrounding tissue, and proximity to the impact point. The results of this research provide insight into the transfer of energy and pressure wave propagation during ballistic impacts using a physical surrogate and computational model of the human torso.

  20. Cortical thickness, cortico-amygdalar networks, and externalizing behaviors in healthy children.

    PubMed

    Ameis, Stephanie H; Ducharme, Simon; Albaugh, Matthew D; Hudziak, James J; Botteron, Kelly N; Lepage, Claude; Zhao, Lu; Khundrakpam, Budhachandra; Collins, D Louis; Lerch, Jason P; Wheeler, Anne; Schachar, Russell; Evans, Alan C; Karama, Sherif

    2014-01-01

    Fronto-amygdalar networks are implicated in childhood psychiatric disorders characterized by high rates of externalizing (aggressive, noncompliant, oppositional) behavior. Although externalizing behaviors are distributed continuously across clinical and nonclinical samples, little is known about how brain variations may confer risk for problematic behavior. Here, we studied cortical thickness, amygdala volume, and cortico-amygdalar network correlates of externalizing behavior in a large sample of healthy children. Two hundred ninety-seven healthy children (6-18 years; mean = 12 ± 3 years), with 517 magnetic resonance imaging scans, from the National Institutes of Health Magnetic Resonance Imaging Study of Normal Brain Development, were studied. Relationships between externalizing behaviors (measured with the Child Behavior Checklist) and cortical thickness, amygdala volume, and cortico-amygdalar structural networks were examined using first-order linear mixed-effects models, after controlling for age, sex, scanner, and total brain volume. Results significant at p ≤ .05, following multiple comparison correction, are reported. Left orbitofrontal, right retrosplenial cingulate, and medial temporal cortex thickness were negatively correlated with externalizing behaviors. Although amygdala volume alone was not correlated with externalizing behaviors, an orbitofrontal cortex-amygdala network predicted rates of externalizing behavior. Children with lower levels of externalizing behaviors exhibited positive correlations between orbitofrontal cortex and amygdala structure, while these regions were not correlated in children with higher levels of externalizing behavior. Our findings identify key cortical nodes in frontal, cingulate, and temporal cortex associated with externalizing behaviors in children; and indicate that orbitofrontal-amygdala network properties may influence externalizing behaviors, along a continuum and across healthy and clinical samples. Copyright © 2014 Society of Biological Psychiatry. Published by Elsevier Inc. All rights reserved.

  1. Crewmans Retention System for Protection against High Speed Ejection up to 600 Knots

    DTIC Science & Technology

    1976-10-01

    articulation and/or removal of the windscreen were to be considered as a standard maintenance procedure for optimum access to equipments, controls, and...crewman quick donning or divestment and easy ac- cess for tightening torso cross strap. The garment provides access to the four Navy torso harness...I: ’-_ _ _ _ - No. S~It OR a - -’" ,. ?, . -I ! _ _ I, I- -1 ,._ _ _ _ .N 00 ’ SS7 30UO J .3 86 NADC-76119-40 I _ __ii ... ..... ... II I .i

  2. Efficacy of Liquid, Air, and Phase Change Material Torso Cooling During Light Exercise While Wearing NBC Clothing

    DTIC Science & Technology

    1998-03-01

    and Thermal Comfort 6 Blood Sampling 6 Statistical Analyses 6 RESULTS 7 Indices of Hydration Status 7 Liquid-Cooling and PCM Cooling Vests...of Uncooled Sites 12 Vapour Pressure 12 Ratings of Thermal Comfort and Perceived Exertion 18 Indices of Heat Tolerance 18 DISCUSSION 20...ill Figures 8A and B Changes in ratings of thermal comfort of the torso and whole body during light exercise at 40°C and 30% relative humidity while

  3. 20. NBS SUIT LAB. TABLE WITH MISCELLANEOUS SUIT PARTS AND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    20. NBS SUIT LAB. TABLE WITH MISCELLANEOUS SUIT PARTS AND TERRY WEST, A SPACE SUIT ASSEMBLY TECHNICIAN LOGGING SUIT PART DATA. PARTS ON THE TABLE ARE A HARD UPPER TORSO (HUT) (REAR LEFT), FULL HELMET (FRONT LEFT), TWO HELMETS WITHOUT PROTECTIVE VISORS, A PAIR OF GLOVES, AND A BACKPACK WITHOUT VOLUMETRIC COVER (REAR RIGHT). THE BACKPACK ATTACHES TO THE HUT TO MAKE-UP THE UPPER TORSO COMPONENTS OF THE SUIT. - Marshall Space Flight Center, Neutral Buoyancy Simulator Facility, Rideout Road, Huntsville, Madison County, AL

  4. Induced venous pooling and cardiorespiratory responses to exercise after bed rest

    NASA Technical Reports Server (NTRS)

    Convertino, V. A.; Sandler, H.; Webb, P.; Annis, J. F.

    1982-01-01

    Venous pooling induced by a specially constructed garment is investigated as a possible means for reversing the reduction in maximal oxygen uptake regularly observed following bed rest. Experiments involved a 15-day period of bed rest during which four healthy male subjects, while remaining recumbent in bed, received daily 210-min venous pooling treatments from a reverse gradient garment supplying counterpressure to the torso. Results of exercise testing indicate that while maximal oxygen uptake endurance time and plasma volume were reduced and maximal heart rate increased after bed rest in the control group, those parameters remained essentially unchanged for the group undergoing venous pooling treatment. Results demonstrate the importance of fluid shifts and venous pooling within the cardiovascular system in addition to physical activity to the maintenance of cardiovascular conditioning.

  5. A structural comparison of female-male and female-female mounting in Japanese macaques (Macaca fuscata).

    PubMed

    Ottenheimer Carrier, Lydia; Leca, Jean-Baptiste; Pellis, Sergio; Vasey, Paul L

    2015-10-01

    In certain populations, female Japanese macaques (Macaca fuscata) mount both males and females. Vasey (2007) proposed that female-female sexual mounting in Japanese macaques may be a neutral evolutionary by-product of a purported adaptation, namely, female-male mounting. In this study, we aim to further examine the proposed link between female-male and female-female mounting in Japanese macaques by comparing the structural characteristics that define both forms of mounting. We do so using Eshkol-Wachman Movement Notation (EWMN), a globographic reference system that can be used to describe the position of body segments. No significant differences were observed in the female mounters' positioning of eight different body segments (i.e., lower torso, mid-torso, upper torso, upper arm, lower arm, upper leg, lower leg, and foot) during female-male and female-female mounting. This finding lends support to the conclusion that female-female and female-male mounting are structurally, and thus, evolutionarily, related. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. BreathSens: A Continuous On-Bed Respiratory Monitoring System With Torso Localization Using an Unobtrusive Pressure Sensing Array.

    PubMed

    Liu, Jason J; Huang, Ming-Chun; Xu, Wenyao; Zhang, Xiaoyi; Stevens, Luke; Alshurafa, Nabil; Sarrafzadeh, Majid

    2015-09-01

    The ability to continuously monitor respiration rates of patients in homecare or in clinics is an important goal. Past research showed that monitoring patient breathing can lower the associated mortality rates for long-term bedridden patients. Nowadays, in-bed sensors consisting of pressure sensitive arrays are unobtrusive and are suitable for deployment in a wide range of settings. Such systems aim to extract respiratory signals from time-series pressure sequences. However, variance of movements, such as unpredictable extremities activities, affect the quality of the extracted respiratory signals. BreathSens, a high-density pressure sensing system made of e-Textile, profiles the underbody pressure distribution and localizes torso area based on the high-resolution pressure images. With a robust bodyparts localization algorithm, respiratory signals extracted from the localized torso area are insensitive to arbitrary extremities movements. In a study of 12 subjects, BreathSens demonstrated its respiratory monitoring capability with variations of sleep postures, locations, and commonly tilted clinical bed conditions.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taylor, Paul A.; Cooper, Candice Frances; Burnett, Damon J.

    Light body armor development for the warfighter is based on trial-and-error testing of prototype designs against ballistic projectiles. Torso armor testing against blast is virtually nonexistent but necessary to ensure adequate protection against injury to the heart and lungs. In this report, we discuss the development of a high-fidelity human torso model, it's merging with the existing Sandia Human Head-Neck Model, and development of the modeling & simulation (M&S) capabilities necessary to simulate wound injury scenarios. Using the new Sandia Human Torso Model, we demonstrate the advantage of virtual simulation in the investigation of wound injury as it relates tomore » the warfighter experience. We present the results of virtual simulations of blast loading and ballistic projectile impact to the tors o with and without notional protective armor. In this manner, we demonstrate the ad vantages of applying a modeling and simulation approach to the investigation of wound injury and relative merit assessments of protective body armor without the need for trial-and-error testing.« less

  8. Preventing Molecular and Particulate Infiltration in a Confined Volume

    NASA Technical Reports Server (NTRS)

    Scialdone, John J.

    1999-01-01

    Contaminants from an instrument's self-generated sources or from sources external to the instrument may degrade its critical surfaces and/or create an environment which limits the instrument's intended performance. Analyses have been carried out on a method to investigate the required purging flow of clean, dry gas to prevent the ingestion of external contaminants into the instrument container volume. The pressure to be maintained and the required flow are examined in terms of their effectiveness in preventing gaseous and particulate contaminant ingestion and abatement of self-generated contaminants in the volume. The required venting area or the existing volume venting area is correlated to the volume to be purged, the allowable pressure differential across the volume, the external contaminant partial pressure, and the sizes of the ambient particulates. The diffusion of external water vapor into the volume while it was being purged was experimentally obtained in terms of an infiltration time constant. That data and the acceptable fraction of the outside pressure into the volume indicate the required flow of purge gas expressed in terms of volume change per unit time. The exclusion of particulates is based on the incoming velocity of the particles and the exit flow speed and density of the purge gas. The purging flow pressures needed to maintain the required flows through the vent passages are indicated. The purge gas must prevent or limit the entrance of the external contaminants to the critical locations of the instrument. It should also prevent self- contamination from surfaces, reduce material outgassing, and sweep out the outgassed products. Systems and facilities that can benefit from purging may be optical equipment, clinical facilities, manufacturing facilities, clean rooms, and other systems requiring clean environments.

  9. High Performance Torso Cooling Garment

    NASA Technical Reports Server (NTRS)

    Conger, Bruce

    2016-01-01

    The concept proposed in this paper is to improve thermal efficiencies of the liquid cooling and ventilation garment (LCVG) in the torso area, which could facilitate removal of LCVG tubing from the arms and legs, thereby increasing suited crew member mobility. EVA space suit mobility in micro-gravity is challenging, and it becomes even more challenging in the gravity of Mars. By using shaped water tubes that greatly increase the contact area with the skin in the torso region of the body, the heat transfer efficiency can be increased. This increase in efficiency could provide the required liquid cooling via torso tubing only; no arm or leg LCVG tubing would be required. Benefits of this approach include increased crewmember mobility, reduced LCVG mass, enhanced evaporation cooling, increased comfort during Mars EVA tasks, and easing of the overly dry condition in the helmet associated with the Advanced Extravehicular Mobility Unit (EMU) ventilation loop currently under development. This report describes analysis and test activities performed to evaluate the potential improvements to the thermal performance of the LCVG. Analyses evaluated potential tube shapes for improving the thermal performance of the LCVG. The analysis results fed into the selection of flat flow strips to improve thermal contact with the skin of the suited test subject. Testing of small segments was performed to compare thermal performance of the tubing approach of the current LCVG to the flat flow strips proposed as the new concept. Results of the testing is presented along with recommendations for future development of this new concept.

  10. High Performance Torso Cooling Garment

    NASA Technical Reports Server (NTRS)

    Conger, Bruce; Makinen, Janice

    2016-01-01

    The concept proposed in this paper is to improve thermal efficiencies of the liquid cooling and ventilation garment (LCVG) in the torso area, which could facilitate removal of LCVG tubing from the arms and legs, thereby increasing suited crew member mobility. EVA space suit mobility in micro-gravity is challenging, and it becomes even more challenging in the gravity of Mars. By using shaped water tubes that greatly increase the contact area with the skin in the torso region of the body, the heat transfer efficiency can be increased. This increase in efficiency could provide the required liquid cooling via torso tubing only; no arm or leg LCVG tubing would be required. Benefits of this approach include increased crewmember mobility, enhanced evaporation cooling, increased comfort during Mars EVA tasks, and easing of the overly dry condition in the helmet associated with the Advanced Extravehicular Mobility Unit (EMU) ventilation loop currently under development. This report describes analysis and test activities performed to evaluate the potential improvements to the thermal performance of the LCVG. Analyses evaluated potential tube shapes for improving the thermal performance of the LCVG. The analysis results fed into the selection of flat flow strips to improve thermal contact with the skin of the suited test subject. Testing of small segments was performed to compare thermal performance of the tubing approach of the current LCVG to the flat flow strips proposed as the new concept. Results of the testing is presented along with recommendations for future development of this new concept.

  11. Motorized dirt bike injuries in children.

    PubMed

    Ramakrishnaiah, Raghu H; Shah, Chetan; Parnell-Beasley, Donna; Greenberg, Bruce S

    2013-04-01

    The number of dirt bike injuries in children in the United States is increasing and poses a public health problem. The purpose of our study was to identify the imaging patterns of dirt bike injuries in children and associations with morbidity and mortality. The study included 85 children (83 boys, 2 girls) <18 year of age (mean age 12.3 years, standard deviation 3 years) with dirt bike injury treated at a tertiary care pediatric hospital. Imaging studies and hospital medical records were reviewed. Outcomes were classified into the following categories: short-term disability, long-term disability or no follow-up available. Imaging studies were reviewed for head, torso, and extremity injuries. One-tailed z test for two proportions was used to determine significant differences between various proportions. Chi-square test with Yates correction was used to determine the significance of long-term disability with injury type. Long bone fractures were the most common injuries. Lower extremity fractures accounted for 79% of extremity fractures and were significantly more common than upper extremity fractures (p = 0.001). Head injuries included fractures (n = 9), brain contusion (n = 5), and meningeal hemorrhage (n = 2). Head injury was associated with long-term disability (p < 0.0001). All torso injuries were solitary. Long-term disability was associated with head injuries but not with torso or extremity injuries. Lower extremity injuries were significantly more common than upper extremity injuries. Torso solid organ injuries were uniformly solitary. Published by Elsevier Inc.

  12. Identification of temporal pathomechanical factors during the tennis serve.

    PubMed

    Martin, Caroline; Kulpa, Richard; Ropars, Mickaël; Delamarche, Paul; Bideau, Benoit

    2013-11-01

    The purpose of this study was twofold: (a) to measure the effects of temporal parameters on both ball velocity and upper limb joint kinetics to identify pathomechanical factors during the tennis serve and (b) to validate these pathomechanical factors by comparing injured and noninjured players. The serves of expert tennis players were recorded with an optoelectronic motion capture system. These experts were then followed during two seasons to identify overuse injuries of the upper limb. Correlation coefficients assessed the relationships between temporal parameters, ball velocity, and peaks of upper limb joint kinetics to identify pathomechanical factors. Temporal parameters and ball velocity were compared between injured and noninjured groups. Temporal pathomechanical factors were identified. The timings of peak angular velocities of pelvis longitudinal rotation, upper torso longitudinal rotation, trunk sagittal rotation, and trunk transverse rotation and the duration between instants of shoulder horizontal adduction and external rotation were significantly related to upper limb joint kinetics and ball velocity. Injured players demonstrated later timings of trunk rotations, improper differences in time between instants of shoulder horizontal adduction and external rotation, lower ball velocities, and higher joint kinetics. The findings of this study imply that improper temporal mechanics during the tennis serve can decrease ball velocity, increase upper limb joint kinetics, and thus possibly increase overuse injuries of the upper limb.

  13. Depth dose distribution study within a phantom torso after irradiation with a simulated Solar Particle Event at NSRL

    NASA Astrophysics Data System (ADS)

    Berger, Thomas; Matthiä, Daniel; Koerner, Christine; George, Kerry; Rhone, Jordan; Cucinotta, Francis A.; Reitz, Guenther

    The adequate knowledge of the radiation environment and the doses incurred during a space mission is essential for estimating an astronaut's health risk. The space radiation environment is complex and variable, and exposures inside the spacecraft and the astronaut's body are com-pounded by the interactions of the primary particles with the atoms of the structural materials and with the body itself. Astronauts' radiation exposures are measured by means of personal dosimetry, but there remains substantial uncertainty associated with the computational extrap-olation of skin dose to organ dose, which can lead to over-or under-estimation of the health risk. Comparisons of models to data showed that the astronaut's Effective dose (E) can be pre-dicted to within about a +10In the research experiment "Depth dose distribution study within a phantom torso" at the NASA Space Radiation Laboratory (NSRL) at BNL, Brookhaven, USA the large 1972 SPE spectrum was simulated using seven different proton energies from 50 up to 450 MeV. A phantom torso constructed of natural bones and realistic distributions of human tissue equivalent materials, which is comparable to the torso of the MATROSHKA phantom currently on the ISS, was equipped with a comprehensive set of thermoluminescence detectors and human cells. The detectors are applied to assess the depth dose distribution and radiation transport codes (e.g. GEANT4) are used to assess the radiation field and interactions of the radiation field with the phantom torso. Lymphocyte cells are strategically embedded at selected locations at the skin and internal organs and are processed after irradiation to assess the effects of shielding on the yield of chromosome damage. The first focus of the pre-sented experiment is to correlate biological results with physical dosimetry measurements in the phantom torso. Further on the results of the passive dosimetry using the anthropomorphic phantoms represent the best tool to generate reliable to benchmark computational radiation transport models in a radiation field of interest. The presentation will give first results of the physical dose distribution, the comparison with GEANT4 computer simulations, based on a Voxel model of the phantom, and a comparison with the data from the chromosome aberration study. The help and support of Adam Russek and Michael Sivertz of the NASA Space Radiation Laboratory (NSRL), Brookhaven, USA during the setup and the irradiation of the phantom are highly appreciated. The Voxel model describing the human phantom used for the GEANT4 simulations was kindly provided by Monika Puchalska (CHALMERS, Gothenburg, Sweden).

  14. Testing the role of external debt in environmental degradation: empirical evidence from Turkey.

    PubMed

    Katircioglu, Salih; Celebi, Aysem

    2018-03-01

    This study investigates the role of external debt stock in Turkey, which has suffered from heavy (external and domestic) debt stock for many years. Annual data from 1960 to 2013 was analyzed using time series analysis in order to study this. The results confirm the validity of the conventional environmental Kuznets curve (EKC) in the case of Turkey. However, this study also found that Turkey's external debt stock did not influence the Turkish economy's long-term EKC behavior. Fortunately, the results suggest that there are important interactions among external debt stock, CO 2 emissions, energy consumption, and real income; that is, changes in external debt volume precede changes in these aggregates' volumes.

  15. Test-retest reliability of automated whole body and compartmental muscle volume measurements on a wide bore 3T MR system.

    PubMed

    Thomas, Marianna S; Newman, David; Leinhard, Olof Dahlqvist; Kasmai, Bahman; Greenwood, Richard; Malcolm, Paul N; Karlsson, Anette; Rosander, Johannes; Borga, Magnus; Toms, Andoni P

    2014-09-01

    To measure the test-retest reproducibility of an automated system for quantifying whole body and compartmental muscle volumes using wide bore 3 T MRI. Thirty volunteers stratified by body mass index underwent whole body 3 T MRI, two-point Dixon sequences, on two separate occasions. Water-fat separation was performed, with automated segmentation of whole body, torso, upper and lower leg volumes, and manually segmented lower leg muscle volumes. Mean automated total body muscle volume was 19·32 L (SD9·1) and 19·28 L (SD9·12) for first and second acquisitions (Intraclass correlation coefficient (ICC) = 1·0, 95% level of agreement -0·32-0·2 L). ICC for all automated test-retest muscle volumes were almost perfect (0·99-1·0) with 95% levels of agreement 1.8-6.6% of mean volume. Automated muscle volume measurements correlate closely with manual quantification (right lower leg: manual 1·68 L (2SD0·6) compared to automated 1·64 L (2SD 0·6), left lower leg: manual 1·69 L (2SD 0·64) compared to automated 1·63 L (SD0·61), correlation coefficients for automated and manual segmentation were 0·94-0·96). Fully automated whole body and compartmental muscle volume quantification can be achieved rapidly on a 3 T wide bore system with very low margins of error, excellent test-retest reliability and excellent correlation to manual segmentation in the lower leg. Sarcopaenia is an important reversible complication of a number of diseases. Manual quantification of muscle volume is time-consuming and expensive. Muscles can be imaged using in and out of phase MRI. Automated atlas-based segmentation can identify muscle groups. Automated muscle volume segmentation is reproducible and can replace manual measurements.

  16. A torso model comparison of temperature preservation devices for use in the prehospital environment.

    PubMed

    Zasa, Michele; Flowers, Neil; Zideman, David; Hodgetts, Timothy J; Harris, Tim

    2016-06-01

    Hypothermia is an independent predictor of increased morbidity and mortality in patients with trauma. Several strategies and products have been developed to minimise patients' heat loss in the prehospital arena, but there is little evidence to inform the clinician concerning their effectiveness. We used a human torso model consisting of two 5.5-litre fluid bags to simultaneously compare four passive (space blanket, bubble wrap, Blizzard blanket, ambulance blanket) and one active (Ready-Heat II blanket) temperature preservation products. A torso model without any temperature preservation device provided a control. For each test, the torso models were warmed to 37°C and left outdoors. Core temperatures were recorded every 10 min for 1 h in total; tests were repeated 10 times. A significant difference in temperature was detected among groups at 30 and 60 min (F (1.29, 10.30)=103.58, p<0.001 and F (1.64, 14.78)=163.28, p<0.001, respectively). Mean temperature reductions (95% CI) after 1 h of environmental exposure were the following: 11.6 (10.3 to 12.9) °C in control group, 4.5 (3.9 to 5.1) °C in space blanket group, 3.6 (3 to 4.3) °C in bubble-wrap group, 2.1 (1.7 to 2.5) °C in Blizzard blanket group, 6.1 (5.8 to 6.5) °C in ambulance blanket group and 1.1 (0.7 to 1.6) °C in Ready-Heat II blanket group. In this study, using a torso model based on two 5 L dialysate bags we found the Ready-Heat II heating blanket and Blizzard blanket were associated with lower rates of heat loss after 60 min environmental exposure than the other devices tested. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  17. Augmentation of blood circulation to the fingers by warming distant body areas

    NASA Technical Reports Server (NTRS)

    Koscheyev, V. S.; Leon, G. R.; Paul, S.; Tranchida, D.; Linder, I. V.

    2000-01-01

    Future activities in space will require greater periods of time in extreme environments in which the body periphery will be vulnerable to chilling. Maintaining the hands and fingers in comfortable conditions enhances finger flexibility and dexterity, and thus effects better work performance. We have evaluated the efficacy of promoting heat transfer and release by the extremities by increasing the blood flow to the periphery from more distant parts of the body. The experimental garment paradigm developed by the investigators was used to manipulate the temperature of different body areas. Six subjects, two females and four males, were evaluated in a stage-1 baseline condition, with the inlet temperature of the circulating water in the liquid cooling/warming garment (LCWG) at 33 degrees C. At stage 2 the total LCWG water inlet temperature was cooled to 8 degrees C, and at stage 3 the inlet water temperature in specific segments of the LCWG was warmed (according to protocol) to 45 degrees C, while the inlet temperature in the rest of the LCWG was maintained at 8 degrees C. The following four body-area-warming conditions were studied in separate sessions: (1) head, (2) upper torso/arm, (3) upper torso/arm/head, and (4) legs/feet. Skin temperature, heat flux and blood perfusion of the fingers, and subjective perception of thermal sensations and overall physical comfort were assessed. Finger temperature (T(fing)) analyses showed a statistically significant condition x stage interaction. Post-hoc comparisons (T(fing)) indicated that at stage 3, the upper torso/arm/head warming condition was significantly different from the head, upper torso/arm and legs/feet conditions, showing an increase in T(fing). There was a significant increase in blood perfusion in the fingers at stage 3 in all conditions. Subjective perception of hand warmth, and overall physical comfort level significantly increased in the stage 3 upper torso/arm/head condition. The findings indicate that physiological methods to enhance heat transfer by the blood to the periphery within protective clothing provide an additional tool for increasing total and local human comfort in extreme environments.

  18. Computational and experimental models of the human torso for non-penetrating ballistic impact.

    PubMed

    Roberts, J C; Merkle, A C; Biermann, P J; Ward, E E; Carkhuff, B G; Cain, R P; O'Connor, J V

    2007-01-01

    Both computational finite element and experimental models of the human torso have been developed for ballistic impact testing. The human torso finite element model (HTFEM), including the thoracic skeletal structure and organs, was created in the finite element code LS-DYNA. The skeletal structure was assumed to be linear-elastic while all internal organs were modeled as viscoelastic. A physical human surrogate torso model (HSTM) was developed using biosimulant materials and the same anthropometry as the HTFEM. The HSTM response to impact was recorded with piezoresistive pressure sensors molded into the heart, liver and stomach and an accelerometer attached to the sternum. For experimentation, the HSTM was outfitted with National Institute of Justice (NIJ) Level I, IIa, II and IIIa soft armor vests. Twenty-six ballistic tests targeting the HSTM heart and liver were conducted with 22 caliber ammunition at a velocity of 329 m/s and 9 mm ammunition at velocities of 332, 358 and 430 m/s. The HSTM pressure response repeatability was found to vary by less than 10% for similar impact conditions. A comparison of the HSTM and HTFEM response showed similar pressure profiles and less than 35% peak pressure difference for organs near the ballistic impact point. Furthermore, the peak sternum accelerations of the HSTM and HTFEM varied by less than 10% for impacts over the sternum. These models provide comparative tools for determining the thoracic response to ballistic impact and could be used to evaluate soft body armor design and efficacy, determine thoracic injury mechanisms and assist with injury prevention.

  19. Restraint harness performance during flight maneuvers: a parametric study.

    PubMed

    Du, Cheng-Fei; Liu, Xiao-Yu; Wang, Li-Zhen; Liu, Song-Yang; Fan, Yu-Bo

    2015-05-01

    Modern super agile fighter aircraft are capable of producing an increasing multiaxial acceleration environment which can adversely affect the pilot. An evaluation of the performance of the restraint system during flight maneuvers will benefit restraint designs and, thus, the safety of pilots. A finite element model of a mannequin with PCU-15/P harness restraint was used in this study to investigate how the factors, such as strap material stiffness, friction, and belt tension, affect the performance of restraint systems during impact along the -Gx, -Gy, and -Gz directions. The corresponding maximum displacement of the mannequin's torso was computed. The mannequin moved beyond 74 mm sideways. The change in friction coefficient (FC) from 0.1 to 0.4 decreased the displacement of the lower torso by less than 6.7%. The displacement of the torso decreased as the stiffness of the strap or tension increased. Displacement decreased by 9.3%, 6.0%, and 2.7% for the lower torso under the Gx impact, as the tightening force increased from 20 N to 80 N gradually. However, this changed slightly when the stiffness arrived at 1 E or the tension increased to 60 N. PCU-15/P harness has the poorest performance during side impact and friction plays an unimportant role in affecting its performance. The stiffness of the webbing used in the PCU-15/P harness is sufficiently high. The lap belt has more effect on limiting the movement of the pilot than the shoulder straps, and a tension of 60 N during the adjustment may be enough for conventional flight maneuvers.

  20. A Computational Study of Injury Severity and Pattern Sustained by Overweight Drivers in Frontal Motor Vehicle Crashes

    PubMed Central

    Kim, Jong-Eun; Kim, Hwan; Shum, Phillip C.; Shih, Alan M.; Pintar, Frank; Shen, Wei; Ma, Xiaoguang; Laud, Purushottam W.; Heymsfield, Steven B.; Allison, David B.; Zhu, Shankuan

    2015-01-01

    The objective of this study was to examine the role of body mass and subcutaneous fat in injury severity and pattern sustained by overweight drivers. Finite element models were created to represent the geometry and properties of subcutaneous adipose tissue in the torso with data obtained from reconstructed magnetic resonance imaging datasets. The torso adipose tissue models were then integrated into the standard multibody dummy models together with increased inertial parameters and sizes of the limbs to represent overweight occupants. Frontal crash simulations were performed considering a variety of occupant restraint systems and regional body injuries were measured. The results revealed that differences in body mass and fat distribution have an impact on injury severity and pattern. Even though the torso adipose tissue of overweight subjects contributed to reduce abdominal injury, the momentum effect of a greater body mass of overweight subjects was more dominant over the cushion effect of the adipose tissue, increasing risk of other regional body injuries except abdomen. Through statistical analysis of the results, strong correlations (p < 0.01) were found between body mass index and regional body injuries except neck injury. The analysis also revealed that a greater momentum of overweight males leads to greater forward torso and pelvic excursions that account for higher risks (p < 0.001) of head, thorax, and lower extremity injury than observed in non-overweight males. The findings have important implications for improving the vehicle and occupant safety systems designed for the increasing global obese population. PMID:23113549

  1. Patient-specific model of a scoliotic torso for surgical planning

    NASA Astrophysics Data System (ADS)

    Harmouche, Rola; Cheriet, Farida; Labelle, Hubert; Dansereau, Jean

    2013-03-01

    A method for the construction of a patient-specific model of a scoliotic torso for surgical planning via inter-patient registration is presented. Magnetic Resonance Images (MRI) of a generic model are registered to surface topography (TP) and X-ray data of a test patient. A partial model is first obtained via thin-plate spline registration between TP and X-ray data of the test patient. The MRIs from the generic model are then fit into the test patient using articulated model registration between the vertebrae of the generic model's MRIs in prone position and the test patient's X-rays in standing position. A non-rigid deformation of the soft tissues is performed using a modified thin-plate spline constrained to maintain bone rigidity and to fit in the space between the vertebrae and the surface of the torso. Results show average Dice values of 0:975 +/- 0:012 between the MRIs following inter-patient registration and the surface topography of the test patient, which is comparable to the average value of 0:976 +/- 0:009 previously obtained following intra-patient registration. The results also show a significant improvement compared to rigid inter-patient registration. Future work includes validating the method on a larger cohort of patients and incorporating soft tissue stiffness constraints. The method developed can be used to obtain a geometric model of a patient including bone structures, soft tissues and the surface of the torso which can be incorporated in a surgical simulator in order to better predict the outcome of scoliosis surgery, even if MRI data cannot be acquired for the patient.

  2. Motion analysis of throwing Boccia balls in children with cerebral palsy.

    PubMed

    Huang, Po-Chang; Pan, Po-Jung; Ou, Yu-Chih; Yu, Yi-Chen; Tsai, Yung-Shen

    2014-02-01

    Boccia is a sport suitable for children with cerebral palsy (CP). Throwing Boccia balls requires upper extremity and torso coordination. This study investigated the differences between children with CP and normally developed children regarding throwing patterns of Boccia balls. Thirteen children with bilateral spastic CP and 20 normally developed children participated in this study. The tests in this study were a pediatric reach test and throwing of Boccia balls. A 3D electromagnetic motion tracking system and a force plate were synchronized to record and analyze biomechanical parameters of throwing Boccia balls. The results of the pediatric reach test for participants with CP were significantly worse than those for normally developed participants. The 2 groups of participants did not significantly differ regarding the distance between a thrown Boccia ball and a target ball (jack). Participants with CP demonstrated significantly longer movement duration, smaller amplitude of elbow movement, greater amplitudes of shoulder abduction and flexion, slower maximal velocity of torso flexion and the linear velocity of moving the wrist joint forward, faster maximal velocity of head flexion, and smaller sway ratio compared with normally developed participants when throwing Boccia balls. Participants with CP seemed to mainly use head and shoulder movements to bring the Boccia balls forward with limited torso movement. Normally developed participants brought the Boccia ball forward with faster torso and greater elbow movement while stabilizing head and shoulder movements. Nevertheless, participants with CP did not demonstrate significantly worse performance in the throwing accuracy of Boccia balls. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. Complex torso reconstruction with human acellular dermal matrix: long-term clinical follow-up.

    PubMed

    Nemeth, Nicole L; Butler, Charles E

    2009-01-01

    Although reports have demonstrated good early outcomes with human acellular dermal matrix even when used for complex, contaminated defects, no long-term outcomes have been reported. The authors reviewed the long-term outcomes of 13 patients who had complex torso reconstructions that included human acellular dermal matrix. All patients were at increased risk for mesh-related complications. Eight patients died as a result of progression of their oncologic disease at a mean of 258 days postoperatively. The mean follow-up for the remaining five patients was 43.7 months. Six patients had early complications (none were human acellular dermal matrix-related) and were reported on previously. Two patients had developed complications since the initial report. One patient developed a flap donor-site seroma remote from the reconstruction site, and another developed a recurrent ventral hernia. No patients have required additional surgery for human acellular dermal matrix-related complications. This follow-up report indicates that human acellular dermal matrix repair of large, complex torso defects can result in good long-term outcomes even when patients are at high risk for mesh-related complications.

  4. ASTRONAUT YOUNG, JOHN W. - ZERO-GRAVITY (ZERO-G) - KC-135

    NASA Image and Video Library

    1978-12-15

    S79-30347 (31 March 1979) --- Taking advantage of a brief period of zero-gravity afforded aboard a KC-135 flying a parabolic curve, the flight crew of the first space shuttle orbital flight test (STS-1) goes through a spacesuit donning exercise. Astronaut John W. Young has just entered the hard-material torso of the shuttle spacesuit by approaching it from below. He is assisted by astronaut Robert L. Crippen. The torso is held in place by a special stand here, simulating the function provided by the airlock wall aboard the actual shuttle craft. The life support system is mated to the torso on Earth and remains so during the flight, requiring this type of donning and doffing exercise. Note Crippen?s suit is the type to be used for intravehicular activity in the shirt sleeve environment to be afforded aboard shuttle. The suit worn by Young is for extravehicular activity (EVA). Young will be STS-1 commander and Crippen, pilot. They will man the space shuttle orbiter 102 Columbia. Photo credit: NASA

  5. [Clinical effect of three dimensional human body scanning system BurnCalc in the evaluation of burn wound area].

    PubMed

    Lu, J; Wang, L; Zhang, Y C; Tang, H T; Xia, Z F

    2017-10-20

    Objective: To validate the clinical effect of three dimensional human body scanning system BurnCalc developed by our research team in the evaluation of burn wound area. Methods: A total of 48 burn patients treated in the outpatient department of our unit from January to June 2015, conforming to the study criteria, were enrolled in. For the first 12 patients, one wound on the limbs or torso was selected from each patient. The stability of the system was tested by 3 attending physicians using three dimensional human body scanning system BurnCalc to measure the area of wounds individually. For the following 36 patients, one wound was selected from each patient, including 12 wounds on limbs, front torso, and side torso, respectively. The area of wounds was measured by the same attending physician using transparency tracing method, National Institutes of Health (NIH) Image J method, and three dimensional human body scanning system BurnCalc, respectively. The time for getting information of 36 wounds by three methods was recorded by stopwatch. The stability among the testers was evaluated by the intra-class correlation coefficient (ICC). Data were processed with randomized blocks analysis of variance and Bonferroni test. Results: (1) Wound area of patients measured by three physicians using three dimensional human body scanning system BurnCalc was (122±95), (121±95), and (123±96) cm(2,) respectively, and there was no statistically significant difference among them ( F =1.55, P >0.05). The ICC among 3 physicians was 0.999. (2) The wound area of limbs of patients measured by transparency tracing method, NIH Image J method, and three dimensional human body scanning system BurnCalc was (84±50), (76±46), and (84±49) cm(2,) respectively. There was no statistically significant difference in the wound area of limbs of patients measured by transparency tracing method and three dimensional human body scanning system BurnCalc ( P >0.05). The wound area of limbs of patients measured by NIH Image J method was smaller than that measured by transparency tracing method and three dimensional human body scanning system BurnCalc (with P values below 0.05). There was no statistically significant difference in the wound area of front torso of patients measured by transparency tracing method, NIH Image J method, and three dimensional human body scanning system BurnCalc ( F =0.33, P >0.05). The wound area of side torso of patients measured by transparency tracing method, NIH Image J method, and three dimensional human body scanning system BurnCalc was (169±88), (150±80), and (169±86) cm(2,) respectively. There was no statistically significant difference in the wound area of side torso of patients measured by transparency tracing method and three dimensional human body scanning system BurnCalc ( P >0.05). The wound area of side torso of patients measured by NIH Image J method was smaller than that measured by transparency tracing method and three dimensional human body scanning system BurnCalc (with P values below 0.05). (3) The time for getting information of wounds of patients by transparency tracing method, NIH Image J method, and three dimensional human body scanning system BurnCalc was (77±14), (10±3), and (9±3) s, respectively. The time for getting information of wounds of patients by transparency tracing method was longer than that by NIH Image J method and three dimensional human body scanning system BurnCalc (with P values below 0.05). The time for getting information of wounds of patients by three dimensional human body scanning system BurnCalc was close to that by NIH Image J method ( P >0.05). Conclusions: The three dimensional human body scanning system BurnCalc is stable and can accurately evaluate the wound area on limbs and torso of burn patients.

  6. Pituitary Volume Prospectively Predicts Internalizing Symptoms in Adolescence

    ERIC Educational Resources Information Center

    Zipursky, Amy R.; Whittle, Sarah; Yucel, Murat; Lorenzetti, Valentina; Wood, Stephen J.; Lubman, Dan I.; Simmons, Julian G.; Allen, Nicholas B.

    2011-01-01

    Background: Early adolescence is a critical time for the development of both internalizing and externalizing disorders. We aimed to investigate whether pituitary volume, an index of hypothalamic-pituitary-adrenal (HPA) axis function, represents a vulnerability factor for the emergence of internalizing and externalizing symptoms during adolescence…

  7. Removal of metabolic heat from man working in a protective suit

    NASA Technical Reports Server (NTRS)

    Shitzer, A.; Chato, J. C.; Hertig, B. A.

    1972-01-01

    A water cooled garment was constructed and used to study the characteristics of independent regional cooling of the body in contrast to the current practice of uniform cooling. The cooling pads in the garment were grouped to provide independent control of water inlet temperatures and flow rates to six regions: head, upper torso, lower torso, arms, thighs, and lower legs. Experiments with and without the cooling suit were conducted with five test subjects standing and walking on a treadmill on selected schedules. Steady state and, to a lesser extent, transient characteristics were obtained.

  8. Depth Dose Distribution Study within a Phantom Torso after Irradiation with a Simulated Solar Particle Event at NSRL

    NASA Technical Reports Server (NTRS)

    Berger, Thomas; Matthiae, Daniel; Koerner, Christine; George, Kerry; Rhone, Jordan; Cucinotta, Francis; Reitz, Guenther

    2010-01-01

    The adequate knowledge of the radiation environment and the doses incurred during a space mission is essential for estimating an astronaut's health risk. The space radiation environment is complex and variable, and exposures inside the spacecraft and the astronaut's body are compounded by the interactions of the primary particles with the atoms of the structural materials and with the body itself Astronauts' radiation exposures are measured by means of personal dosimetry, but there remains substantial uncertainty associated with the computational extrapolation of skin dose to organ dose, which can lead to over- or underestimation of the health risk. Comparisons of models to data showed that the astronaut's Effective dose (E) can be predicted to within about a +10% accuracy using space radiation transport models for galactic cosmic rays (GCR) and trapped radiation behind shielding. However for solar particle event (SPE) with steep energy spectra and for extra-vehicular activities on the surface of the moon where only tissue shielding is present, transport models predict that there are large differences in model assumptions in projecting organ doses. Therefore experimental verification of SPE induced organ doses may be crucial for the design of lunar missions. In the research experiment "Depth dose distribution study within a phantom torso" at the NASA Space Radiation Laboratory (NSRL) at BNL, Brookhaven, USA the large 1972 SPE spectrum was simulated using seven different proton energies from 50 up to 450 MeV. A phantom torso constructed of natural bones and realistic distributions of human tissue equivalent materials, which is comparable to the torso of the MATROSHKA phantom currently on the ISS, was equipped with a comprehensive set of thermoluminescence detectors and human cells. The detectors are applied to assess the depth dose distribution and radiation transport codes (e.g. GEANT4) are used to assess the radiation field and interactions of the radiation field with the phantom torso. Lymphocyte cells are strategically embedded at selected locations at the skin and internal organs and are processed after irradiation to assess the effects of shielding on the yield of chromosome damage. The initial focus of the present experiment is to correlate biological results with physical dosimetry measurements in the phantom torso. Further on, the results of the passive dosimetry within the anthropomorphic phantoms represent the best tool to generate reliable data to benchmark computational radiation transport models in a radiation field of interest. The presentation will give first results of the physical dose distribution, the comparison with GEANT4 computer simulations based on a Voxel model of the phantom, and a comparison with the data from the chromosome aberration study.

  9. Air Quality Criteria for Ozone and Related Photochemical Oxidants (Second External Review Draft)

    EPA Science Inventory

    This second external review draft of the Air Quality Criteria for Ozone and Related Photochemical Oxidants, Volumes I-III (Ozone Criteria Document) is being released for public comment and for review by EPA's Clean Air Scientific Advisory Committee (CASAC) r...

  10. AIR QUALITY CRITERIA FOR PARTICULATE MATTER, VOLUMES I-III, (EXTERNAL REVIEW DRAFT, 1995)

    EPA Science Inventory

    There is no abstract available for these documents.

    If further information is requested, please refer to the bibliographic citation and contact the Technical Information Staff at the number listed above.

    • Air Quality Criteria for Particulate Matter, Volume I, Extern...

    • Protective supplied breathing air garment

      DOEpatents

      Childers, E.L.; Hortenau, E.F. von.

      1984-07-10

      A breathing air garment is disclosed for isolating a wearer from hostile environments containing toxins or irritants includes a suit and a separate head protective enclosure or hood engaging a suit collar in sealing attachment. The hood and suit collar are cylindrically shaped and dimensioned to enable the wearer to withdraw his hands from the suit sleeves to perform manual tasks within the hood interior. Breathing air is supplied from an external air line with an air delivery hose attached to the hood interior. The hose feeds air into an annular halo-like fiber-filled plenum having spaced discharge orifices attached to the hood top wall. A plurality of air exhaust/check valves located at the suit extremities cooperate with the hood air delivery system to provide a cooling flow of circulating air from the hood throughout the suit interior. A suit entry seal provided on the suit rear torso panel permits access into the suit and is sealed with an adhesive sealing flap. 17 figs.

    • On the dynamics of a human body model.

      NASA Technical Reports Server (NTRS)

      Huston, R. L.; Passerello, C. E.

      1971-01-01

      Equations of motion for a model of the human body are developed. Basically, the model consists of an elliptical cylinder representing the torso, together with a system of frustrums of elliptical cones representing the limbs. They are connected to the main body and each other by hinges and ball and socket joints. Vector, tensor, and matrix methods provide a systematic organization of the geometry. The equations of motion are developed from the principles of classical mechanics. The solution of these equations then provide the displacement and rotation of the main body when the external forces and relative limb motions are specified. Three simple example motions are studied to illustrate the method. The first is an analysis and comparison of simple lifting on the earth and the moon. The second is an elementary approach to underwater swimming, including both viscous and inertia effects. The third is an analysis of kicking motion and its effect upon a vertically suspended man such as a parachutist.

    • Do Vascular Networks Branch Optimally or Randomly across Spatial Scales?

      PubMed Central

      Newberry, Mitchell G.; Savage, Van M.

      2016-01-01

      Modern models that derive allometric relationships between metabolic rate and body mass are based on the architectural design of the cardiovascular system and presume sibling vessels are symmetric in terms of radius, length, flow rate, and pressure. Here, we study the cardiovascular structure of the human head and torso and of a mouse lung based on three-dimensional images processed via our software Angicart. In contrast to modern allometric theories, we find systematic patterns of asymmetry in vascular branching, potentially explaining previously documented mismatches between predictions (power-law or concave curvature) and observed empirical data (convex curvature) for the allometric scaling of metabolic rate. To examine why these systematic asymmetries in vascular branching might arise, we construct a mathematical framework to derive predictions based on local, junction-level optimality principles that have been proposed to be favored in the course of natural selection and development. The two most commonly used principles are material-cost optimizations (construction materials or blood volume) and optimization of efficient flow via minimization of power loss. We show that material-cost optimization solutions match with distributions for asymmetric branching across the whole network but do not match well for individual junctions. Consequently, we also explore random branching that is constrained at scales that range from local (junction-level) to global (whole network). We find that material-cost optimizations are the strongest predictor of vascular branching in the human head and torso, whereas locally or intermediately constrained random branching is comparable to material-cost optimizations for the mouse lung. These differences could be attributable to developmentally-programmed local branching for larger vessels and constrained random branching for smaller vessels. PMID:27902691

    • The feasibility of laryngoscope-guided tracheal intubation in microgravity during parabolic flight: a comparison of two techniques.

      PubMed

      Groemer, Gernot E; Brimacombe, Joseph; Haas, Thorsten; de Negueruela, Cristina; Soucek, Alexander; Thomsen, Michael; Keller, Christian

      2005-11-01

      We determined the feasibility of laryngoscope-guided tracheal intubation (LG-TI) in microgravity obtained during parabolic flight and tested the hypothesis that LG-TI is similarly successful in the free-floating condition, with the patient's head gripped between the anesthesiologist's knees, as in the restrained condition, with the torso strapped to the surface. Three personnel with no experience in airway management or microgravity participated in the study. LG-TI of a sophisticated full-size manikin was attempted on seven occasions in each condition by each investigator after ground-based training. The parabolic flights, which took place in an Airbus 300 over the Atlantic Ocean, provided 23 s of microgravity. During this time, the investigator opened a box with airway equipment, performed LG-TI, and attached and held onto a self-inflating bag. The efficacy of ventilation was assessed during level flight by squeezing the bag and noting whether the manikin sensors indicated a tidal volume > or =300 mL. There were no differences in ventilation success (41% versus 33%) or time to successful insertion (both 18 s) between the free-floating and the restrained conditions. More than 90% of failures were caused by the inability to insert the tracheal tube within 23 s. There were no differences in performance among investigators. We conclude that LG-TI is feasible in microgravity obtained during parabolic flight, but the success rate is infrequent because of severe time restrictions. There were no differences in success rate between the free-floating condition, with the head gripped between the knees, and the restrained condition, with the torso strapped to the surface.

    • Effects of balance ability and handgrip height on kinematics of the gait, torso, and pelvis in elderly women using a four-wheeled walker.

      PubMed

      Choi, Hyuk-Jae; Ko, Chang-Yong; Kang, Sungjae; Ryu, Jeicheong; Mun, Museong; Jeon, Hye-Seon

      2015-02-01

      Numerous elderly individuals use the four-wheeled walker (FWW) as a gait-assistive device. The walker's handgrip height is important for correct use. However, few clinical studies have investigated the biomechanical effects of the FWW's handgrip height on balance. Therefore, the present study assessed kinematic features of the gait, torso and pelvis during use of the FWW at two levels of handgrip height (48% vs 55% of the subject's height) while assessing balance in older adults. A total of 20 older adults were allocated into two groups according to the Berg Balance Scale (BBS): good balance (GB; BBS≥46) versus poor balance (PB; BBS<45). Participants walked with the FWW at 48% or 55% handgrip height for 10 m. Our study showed that the double-support period and stance phase significantly increased at 55% handgrip height, but the swing phase significantly decreased in the GB group. In the PB group, velocity and stride length significantly increased at 55% handgrip height. Tilt angle of the torso in the GB group was significantly lower at 55% than at 48% handgrip height, but no differences were observed in the PB group. In the pelvis, initial contact and toe-off angles of tilt were lower in the GB group at 55% handgrip height, but no differences were observed in the PB group. These results showed that kinematic features of the gait, torso, and pelvis in older adults using the FWW might be dependent on the handgrip height of the FWW and the patient's balance. Additionally, greater than 48% of the body height might be appropriate for older adults with poor balance. © 2014 Japan Geriatrics Society.

    • Predictors of Intrathoracic Injury after Blunt Torso Trauma in Children Presenting to an Emergency Department as Trauma Activations.

      PubMed

      McNamara, Caitlin; Mironova, Irina; Lehman, Erik; Olympia, Robert P

      2017-06-01

      Thoracic injuries are a major cause of death associated with blunt trauma in children. Screening for injury with chest x-ray study, compared with chest computed tomography (CT) scan, has been controversial, weighing the benefits of specificity with the detriment of radiation exposure. To identify predictors of thoracic injury in children presenting as trauma activations to a Level I trauma center after blunt torso trauma, and to compare these predictors with those previously reported in the literature. We performed a retrospective chart review of pediatric patients (<18 years of age) who presented to the Emergency Department of a Level I trauma center between June 2010 and June 2013 as a trauma activation after sustaining a blunt torso trauma and who received diagnostic imaging of the chest as part of their initial evaluation. Data analysis was performed on 166 patients. There were 33 patients (20%) with 45 abnormalities detected on diagnostic imaging of the chest, with the most common abnormalities being lung contusion (36%), pneumothorax (22%), and rib fracture (13%). Statistically significant predictors of abnormal diagnostic imaging of the chest included Glasgow Coma Scale score (GCS) < 15 (27% with abnormality vs. 13% without abnormality), hypoxia (22% vs. 5%), syncope/loss of consciousness (55% vs. 35%), cervical spine tenderness (12% vs. 3%), thoraco-lumbar-sacral spine tenderness (41% vs. 17%), and abdominal/pelvic tenderness (12% vs. 3%). Based on our data, predictors of thoracic injury in children after blunt torso trauma include GCS < 15, hypoxia, syncope/dizziness, cervical spine tenderness, thoraco-lumbar-sacral spine tenderness, and abdominal/pelvic tenderness. Copyright © 2016 Elsevier Inc. All rights reserved.

    • Efficacy of side airbags in reducing driver deaths in driver-side car and SUV collisions.

      PubMed

      McCartt, Anne T; Kyrychenko, Sergey Y

      2007-06-01

      To estimate the efficacy of side airbags in preventing driver deaths in passenger vehicles struck on the driver side. Risk ratios for driver deaths per driver-side collision were computed for side airbag-equipped cars and SUVs, relative to vehicles without side airbags. Driver fatality ratios also were calculated for the same vehicles in front and rear impacts, and these were used to adjust the side crash risk ratios for differences in fatality risk unrelated to side airbags. Risk ratios were calculated separately for side airbags providing torso-only protection and side airbags with head protection; almost all head protecting airbags also had airbags protecting the torso. Car driver death risk in driver-side crashes was reduced by 37 percent for head protecting airbags and 26 percent for torso-only side airbags. Car driver death risk was reduced for older and younger drivers, males and females, and drivers of small and midsize cars, and when the striking vehicle was an SUV/pickup or a car/minivan. Death risk for drivers of SUVs was reduced by 52 percent with head protecting side airbags and by 30 percent with torso-only airbags. The effectiveness of side airbags could not be assessed for pickups and minivans due to the small number of these vehicles with airbags involved in crashes. Side airbags substantially reduce the risk of car and SUV driver death in driver-side collisions. Making side airbags with head protection available to drivers and right front passengers in all passenger vehicles could reduce the number of fatalities in motor vehicle crashes in the United States by about 2,000 each year.

    • Therapeutically equivalent pharmacokinetic profile across three application sites for AG200-15, a novel low-estrogen dose contraceptive patch.

      PubMed

      Stanczyk, Frank Z; Archer, David F; Rubin, Arkady; Foegh, Marie

      2013-06-01

      AG200-15 Agile Patch (AP) is a novel 7-day contraceptive patch providing ethinyl estradiol (EE) exposure comparable to low-dose combination oral contraceptives. This study determined whether application of the AP to three different anatomical sites (lower abdomen, buttock and upper torso) influences the pharmacokinetic profile of EE and levonorgestrel (LNG). In this open-label, three-period, crossover study, 24 subjects were randomized to one of six treatment sequences; each included application of patch to abdomen, buttock and upper torso, with the AP worn on one site for 7 days. After a 7-day washout, a new patch was applied to the next anatomical site. Multiple blood samples were collected up to 240 h after patch application. For plasma EE levels, median time to maximum drug concentration (Tmax, 24-48 h) and mean maximum concentration (Cmax, 47.9-61.5 pg/mL) were similar among application sites. Compared with lower abdomen, EE exposure was higher (16%-30%) at buttock and upper torso (15%-22%). For plasma LNG levels, median Tmax (72-120 h) and mean Cmax (1436-1589 pg/mL) were similar across application sites. Compared with lower abdomen, LNG exposure was higher at buttock (1%-7%) and upper torso (16%-17%). No serious adverse events (AEs) or AE-related discontinuations occurred. The most common treatment-emergent AEs were nausea, application site pruritus and headache, with frequencies comparable across anatomical sites. Absorption from the abdomen was slightly lower versus other sites; however, exposure to EE and LNG for all sites was therapeutically equivalent. The AP was well tolerated at all three anatomical sites. Copyright © 2013 Elsevier Inc. All rights reserved.

    • Validation of stereophotogrammetry of the human torso.

      PubMed

      Lee, Juhun; Kawale, Manas; Merchant, Fatima A; Weston, June; Fingeret, Michelle C; Ladewig, Dianne; Reece, Gregory P; Crosby, Melissa A; Beahm, Elisabeth K; Markey, Mia K

      2011-02-15

      The objective of this study was to determine if measurements of breast morphology computed from three-dimensional (3D) stereophotogrammetry are equivalent to traditional anthropometric measurements obtained directly on a subject using a tape measure. 3D torso images of 23 women ranged in age from 36 to 63 who underwent or were scheduled for breast reconstruction surgery were obtained using a 3dMD torso system (3Q Technologies Inc., Atlanta, GA). Two different types (contoured and line-of-sight distances) of a total of nine distances were computed from 3D images of each participant. Each participant was photographed twice, first without fiducial points marked (referred to as unmarked image) and second with fiducial points marked prior to imaging (referred to as marked image). Stereophotogrammetry was compared to traditional direct anthropometry, in which measurements were taken with a tape measure on participants. Three statistical analyses were used to evaluate the agreement between stereophotogrammetry and direct anthropometry. Seven out of nine distances showed excellent agreement between stereophotogrammetry and direct anthropometry (both marked and unmarked images). In addition, stereophotogrammetry from the unmarked image was equivalent to that of the marked image (both line-of-sight and contoured distances). A lower level of agreement was observed for some measures because of difficulty in localizing more vaguely defined fiducial points, such as lowest visible point of breast mound, and inability of the imaging system in capturing areas obscured by the breast, such as the inframammary fold. Stereophotogrammetry from 3D images obtained from the 3dMD torso system is effective for quantifying breast morphology. Tools for surgical planning and evaluation based on stereophotogrammetry have the potential to improve breast surgery outcomes.

    • Interlimb Coordination in Body-Weight Supported Locomotion: A Pilot Study

      PubMed Central

      Seiterle, Stefan; Susko, Tyler; Artemiadis, Panagiotis K.; Riener, Robert; Krebs, Hermano Igo

      2015-01-01

      Locomotion involves complex neural networks responsible for automatic and volitional actions. During locomotion, motor strategies can rapidly compensate for any obstruction or perturbation that could interfere with forward progression. In this pilot study, we examined the contribution of interlimb pathways for evoking muscle activation patterns in the contralateral limb when a unilateral perturbation was applied and in the case where body weight was externally supported. In particular, the latency of neuromuscular responses was measured, while the stimulus to afferent feedback was limited. The pilot experiment was conducted with six healthy young subjects. It employed the MIT-Skywalker (beta-prototype), a novel device intended for gait therapy. Subjects were asked to walk on the split-belt treadmill, while a fast unilateral perturbation was applied mid-stance by unexpectedly lowering one side of the split-treadmill walking surfaces. Subject's weight was externally supported via the body-weight support system consisting of an underneath bicycle seat and the torso was stabilized via a loosely fitted chest harness. Both the weight support and the chest harness limited the afferent feedback. The unilateral perturbations evoked changes in the electromyographic activity of the non-perturbed contralateral leg. The latency of all muscle responses exceeded 100 ms, which precludes the conjecture that spinal cord alone is responsible for the perturbation response. It suggests the role of supraspinal or midbrain level pathways at the inter-leg coordination during gait. PMID:25990210

  1. The effect of laparotomy and external fixator stabilization on pelvic volume in an unstable pelvic injury.

    PubMed

    Ghanayem, A J; Wilber, J H; Lieberman, J M; Motta, A O

    1995-03-01

    Determine if laparotomy further destabilizes an unstable pelvic injury and increases pelvic volume, and if reduction and stabilization restores pelvic volume and prevents volume changes secondary to laparotomy. Cadaveric pelvic fracture model. Unilateral open-book pelvic ring injuries were created in five fresh cadaveric specimens by directly disrupting the pubic symphysis, left sacroliac joint, and sacrospinous and sacrotuberous ligaments. Pelvic volume was determined using computerized axial tomography for the intact pelvis, disrupted pelvis with both a laparotomy incision opened and closed, and disrupted pelvis stabilized and reduced using an external fixator with the laparotomy incision opened. The average volume increase in the entire pelvis (from the top of the iliac crests to the bottom of the ischial tuberosities) between a nonstabilized injury with the abdomen closed and then subsequently opened was 15 +/- 5% (423 cc). The average increase in entire pelvic volume between a stabilized and reduced pelvis and nonstabilized pelvis, both with the abdomen open, was 26 +/- 5% (692 cc). The public diastasis increased from 3.9 to 9.3 cm in a nonstabilized pelvis with the abdomen closed and then subsequently opened. Application of a single-pin anterior-frame external fixator reduced the pubic diastasis anatomically and reduced the average entire and true (from the pelvic brim to the ischeal tuberosities) pelvic volumes to within 3 +/- 4 and 8 +/- 6% of the initial volume, respectively. We believe that the abdominal wall provides stability to an unstable pelvic ring injury via a tension band effect on the iliac wings. Our results demonstrate that a laparotomy further destabilized an open-book pelvic injury and subsequently increased pelvic volume and pubic diastasis. This could potentially increase blood loss from the pelvic injury and delay the tamponade effect of reduction and stabilization. A single-pin external fixator prevents the destabilizing effect of the laparotomy and effectively reduces pelvic volume. These data support reduction and temporary stabilization of unstable pelvic injuries before or concomitantly with laparotomy.

  2. Computation and projection of spiral wave trajectories during atrial fibrillation: a computational study.

    PubMed

    Pashaei, Ali; Bayer, Jason; Meillet, Valentin; Dubois, Rémi; Vigmond, Edward

    2015-03-01

    To show how atrial fibrillation rotor activity on the heart surface manifests as phase on the torso, fibrillation was induced on a geometrically accurate computer model of the human atria. The Hilbert transform, time embedding, and filament detection were compared. Electrical activity on the epicardium was used to compute potentials on different surfaces from the atria to the torso. The Hilbert transform produces erroneous phase when pacing for longer than the action potential duration. The number of phase singularities, frequency content, and the dominant frequency decreased with distance from the heart, except for the convex hull. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Feasibility of Using Wideband Microwave System for Non-Invasive Detection and Monitoring of Pulmonary Oedema

    NASA Astrophysics Data System (ADS)

    Rezaeieh, S. Ahdi; Zamani, A.; Bialkowski, K. S.; Mahmoud, A.; Abbosh, A. M.

    2015-09-01

    Pulmonary oedema is a common manifestation of various fatal diseases that can be caused by cardiac or non-cardiac syndromes. The accumulated fluid has a considerably higher dielectric constant compared to lungs’ tissues, and can thus be detected using microwave techniques. Therefore, a non-invasive microwave system for the early detection of pulmonary oedema is presented. It employs a platform in the form of foam-based bed that contains two linear arrays of wideband antennas covering the band 0.7-1 GHz. The platform is designed such that during the tests, the subject lays on the bed with the back of the torso facing the antenna arrays. The antennas are controlled using a switching network that is connected to a compact network analyzer. A novel frequency-based imaging algorithm is used to process the recorded signals and generate an image of the torso showing any accumulated fluids in the lungs. The system is verified on an artificial torso phantom, and animal organs. As a feasibility study, preclinical tests are conducted on healthy subjects to determinate the type of obtained images, the statistics and threshold levels of their intensity to differentiate between healthy and unhealthy subjects.

  4. The Phonetics of Head and Body Movement in the Realization of American Sign Language Signs.

    PubMed

    Tyrone, Martha E; Mauk, Claude E

    2016-01-01

    Because the primary articulators for sign languages are the hands, sign phonology and phonetics have focused mainly on them and treated other articulators as passive targets. However, there is abundant research on the role of nonmanual articulators in sign language grammar and prosody. The current study examines how hand and head/body movements are coordinated to realize phonetic targets. Kinematic data were collected from 5 deaf American Sign Language (ASL) signers to allow the analysis of movements of the hands, head and body during signing. In particular, we examine how the chin, forehead and torso move during the production of ASL signs at those three phonological locations. Our findings suggest that for signs with a lexical movement toward the head, the forehead and chin move to facilitate convergence with the hand. By comparison, the torso does not move to facilitate convergence with the hand for signs located at the torso. These results imply that the nonmanual articulators serve a phonetic as well as a grammatical or prosodic role in sign languages. Future models of sign phonetics and phonology should take into consideration the movements of the nonmanual articulators in the realization of signs. © 2016 S. Karger AG, Basel.

  5. Feasibility of Using Wideband Microwave System for Non-Invasive Detection and Monitoring of Pulmonary Oedema

    PubMed Central

    Rezaeieh, S. Ahdi; Zamani, A.; Bialkowski, K. S.; Mahmoud, A.; Abbosh, A. M.

    2015-01-01

    Pulmonary oedema is a common manifestation of various fatal diseases that can be caused by cardiac or non-cardiac syndromes. The accumulated fluid has a considerably higher dielectric constant compared to lungs’ tissues, and can thus be detected using microwave techniques. Therefore, a non-invasive microwave system for the early detection of pulmonary oedema is presented. It employs a platform in the form of foam-based bed that contains two linear arrays of wideband antennas covering the band 0.7–1 GHz. The platform is designed such that during the tests, the subject lays on the bed with the back of the torso facing the antenna arrays. The antennas are controlled using a switching network that is connected to a compact network analyzer. A novel frequency-based imaging algorithm is used to process the recorded signals and generate an image of the torso showing any accumulated fluids in the lungs. The system is verified on an artificial torso phantom, and animal organs. As a feasibility study, preclinical tests are conducted on healthy subjects to determinate the type of obtained images, the statistics and threshold levels of their intensity to differentiate between healthy and unhealthy subjects. PMID:26365299

  6. The influence of breast support on torso, pelvis and arm kinematics during a five kilometer treadmill run.

    PubMed

    Milligan, Alexandra; Mills, Chris; Corbett, Jo; Scurr, Joanna

    2015-08-01

    Many women wear sports bras due to positive benefits associated with these garments (i.e. reduction in breast movement and breast pain), however the effects these garments have on upper body running kinematics has not been investigated. Ten female participants (32 DD or 34 D) completed two five kilometer treadmill runs (9 km h(-1)), once in a low and once in a high breast support. The range of motion (ROM) and peak torso, pelvis, and upper arm Cardan joint angles were calculated over five gait cycles during a five kilometer run. Peak torso yaw, peak rotation of the pelvis, peak pelvis obliquity, ROM in rotation of the pelvis, and ROM in upper arm extension were significant, but marginally reduced when participants ran in the high breast support. The running kinematics reported in the high breast support condition more closely align with economical running kinematics previously defined in the literature, therefore, running in a high breast support may be more beneficial to female runners, with a high breast support advocated for middle distance runners. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Multi-antioxidant supplementation does not prevent an increase in gut permeability after lower torso ischemia and reperfusion in humans.

    PubMed

    Wijnen, M H W A; Vader, H L; Roumen, R M H

    2002-01-01

    An increase in gut permeability can have serious consequences leading to sepsis and multiple organ failure. After lower torso ischemia an increase in gut permeability is seen in both animals and humans. There is proof that this can be modified by antioxidant supplementation. In this prospective, randomized study we have looked at the influence of a multiantioxidant supplementation regime, using allopurinol, vitamins E and C, mannitol and N-acetylcysteine, perioperatively. Twenty-two patients received standard treatment and 20 patients received supplementation. Gut permeability was determined using a double sugar test with lactulose and rhamnose. A significant increase in gut permeability was found neither in the non-treatment group (p = 0.012) nor in the treatment group (p = 0.006) after 6 and 24 h. No difference was found between the group receiving antioxidants and the standard treatment group. p = 0.93 6 h post clamp; p = 0.97 24 h post clamp. In this study we have not found an influence of multiantioxidant supplementation on gut permeability after lower torso ischemia. Possible explanations for this negative result are being discussed. Copyright 2002 S. Karger AG, Basel

  8. Usefulness of model-based iterative reconstruction in semi-automatic volumetry for ground-glass nodules at ultra-low-dose CT: a phantom study.

    PubMed

    Maruyama, Shuki; Fukushima, Yasuhiro; Miyamae, Yuta; Koizumi, Koji

    2018-06-01

    This study aimed to investigate the effects of parameter presets of the forward projected model-based iterative reconstruction solution (FIRST) on the accuracy of pulmonary nodule volume measurement. A torso phantom with simulated nodules [diameter: 5, 8, 10, and 12 mm; computed tomography (CT) density: - 630 HU] was scanned with a multi-detector CT at tube currents of 10 mA (ultra-low-dose: UL-dose) and 270 mA (standard-dose: Std-dose). Images were reconstructed with filtered back projection [FBP; standard (Std-FBP), ultra-low-dose (UL-FBP)], FIRST Lung (UL-Lung), and FIRST Body (UL-Body), and analyzed with a semi-automatic software. The error in the volume measurement was determined. The errors with UL-Lung and UL-Body were smaller than that with UL-FBP. The smallest error was 5.8% ± 0.3 for the 12-mm nodule with UL-Body (middle lung). Our results indicated that FIRST Body would be superior to FIRST Lung in terms of accuracy of nodule measurement with UL-dose CT.

  9. The impact of patient volume on surgical trauma training in a Scandinavian trauma centre.

    PubMed

    Gaarder, Christine; Skaga, Nils Oddvar; Eken, Torsten; Pillgram-Larsen, Johan; Buanes, Trond; Naess, Paal Aksel

    2005-11-01

    Some of the problems faced in trauma surgery are increasing non-operative management of abdominal injuries, decreasing work hours and increasing sub-specialisation. We wanted to document the experience of trauma team leaders at the largest trauma centre in Norway, hypothesising that the patient volume would be inadequate to secure optimal trauma care. Patients registered in the hospital based Trauma Registry during the 2-year period from 1 August 2000 to 31 July 2002 were included. Of a total of 1667 patients registered, 645 patients (39%) had an Injury Severity Score (ISS)>15. Abdominal injuries were diagnosed in 205 patients with a median ISS of 30. An average trauma team leader assessed a total of 119 trauma cases a year (46 patients with ISS>15) and participated in 10 trauma laparotomies. Although the total number of trauma cases seems adequate, the experience of the trauma team leaders with challenging abdominal injuries is limited. With increasing sub-specialisation and general surgery vanishing, fewer surgical specialties provide operative competence in dealing with complicated torso trauma. A system of additional education and quality assurance measures is a prerequisite of high quality, and has consequently been introduced in our institution.

  10. Automated tumour boundary delineation on 18F-FDG PET images using active contour coupled with shifted-optimal thresholding method

    NASA Astrophysics Data System (ADS)

    Khamwan, Kitiwat; Krisanachinda, Anchali; Pluempitiwiriyawej, Charnchai

    2012-10-01

    This study presents an automatic method to trace the boundary of the tumour in positron emission tomography (PET) images. It has been discovered that Otsu's threshold value is biased when the within-class variances between the object and the background are significantly different. To solve the problem, a double-stage threshold search that minimizes the energy between the first Otsu's threshold and the maximum intensity value is introduced. Such shifted-optimal thresholding is embedded into a region-based active contour so that both algorithms are performed consecutively. The efficiency of the method is validated using six sphere inserts (0.52-26.53 cc volume) of the IEC/2001 torso phantom. Both spheres and phantom were filled with 18F solution with four source-to-background ratio (SBR) measurements of PET images. The results illustrate that the tumour volumes segmented by combined algorithm are of higher accuracy than the traditional active contour. The method had been clinically implemented in ten oesophageal cancer patients. The results are evaluated and compared with the manual tracing by an experienced radiation oncologist. The advantage of the algorithm is the reduced erroneous delineation that improves the precision and accuracy of PET tumour contouring. Moreover, the combined method is robust, independent of the SBR threshold-volume curves, and it does not require prior lesion size measurement.

  11. Application of long-period grating sensors to respiratory function monitoring

    NASA Astrophysics Data System (ADS)

    Allsop, Thomas D.; Earthrowl, Tim; Revees, Richard; Webb, David J.; Miller, Martin; Jones, Barrie W.; Bennion, Ian

    2004-12-01

    A series of in-line curvature sensors on a garment are used to monitor the thoracic and abdominal movements of a human during respiration. These results are used to obtain volumetric tidal changes of the human torso showing reasonable agreement with a spirometer used simultaneously to record the volume at the mouth during breathing. The curvature sensors are based upon long period gratings written in a progressive three layered fibre that are insensitive to refractive index changes. The sensor platform consists of the long period grating laid upon a carbon fibre ribbon, which is encapsulated in a low temperature curing silicone rubber. An array of sensors is also used to reconstruct the shape changes of a resuscitation manikin during simulated respiration. The data for reconstruction is obtained by two methods of multiplexing and interrogation: firstly using the transmission spectral profile of the LPG's attenuation bands measured using an optical spectrum analyser; secondly using a derivative spectroscopy technique.

  12. SU-D-9A-01: Listmode-Driven Optimal Gating (OG) Respiratory Motion Management: Potential Impact On Quantitative PET Imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, K; Hristov, D

    2014-06-01

    Purpose: To evaluate the potential impact of listmode-driven amplitude based optimal gating (OG) respiratory motion management technique on quantitative PET imaging. Methods: During the PET acquisitions, an optical camera tracked and recorded the motion of a tool placed on top of patients' torso. PET event data were utilized to detect and derive a motion signal that is directly coupled with a specific internal organ. A radioactivity-trace was generated from listmode data by accumulating all prompt counts in temporal bins matching the sampling rate of the external tracking device. Decay correction for 18F was performed. The image reconstructions using OG respiratorymore » motion management technique that uses 35% of total radioactivity counts within limited motion amplitudes were performed with external motion and radioactivity traces separately with ordered subset expectation maximization (OSEM) with 2 iterations and 21 subsets. Standard uptake values (SUVs) in a tumor region were calculated to measure the effect of using radioactivity trace for motion compensation. Motion-blurred 3D static PET image was also reconstructed with all counts and the SUVs derived from OG images were compared with SUVs from 3D images. Results: A 5.7 % increase of the maximum SUV in the lesion was found for optimal gating image reconstruction with radioactivity trace when compared to a static 3D image. The mean and maximum SUVs on the image that was reconstructed with radioactivity trace were found comparable (0.4 % and 4.5 % increase, respectively) to the values derived from the image that was reconstructed with external trace. Conclusion: The image reconstructed using radioactivity trace showed that the blurring due to the motion was reduced with impact on derived SUVs. The resolution and contrast of the images reconstructed with radioactivity trace were comparable to the resolution and contrast of the images reconstructed with external respiratory traces. Research supported by Siemens.« less

  13. 3D quantification of microclimate volume in layered clothing for the prediction of clothing insulation.

    PubMed

    Lee, Yejin; Hong, Kyunghi; Hong, Sung-Ae

    2007-05-01

    Garment fit and resultant air volume is a crucial factor in thermal insulation, and yet, it has been difficult to quantify the air volume of clothing microclimate and relate it to the thermal insulation value just using the information on the size of clothing pattern without actual 3D volume measurement in wear condition. As earlier methods for the computation of air volume in clothing microclimate, vacuum over suit and circumference model have been used. However, these methods have inevitable disadvantages in terms of cost or accuracy due to the limitations of measurement equipment. In this paper, the phase-shifting moiré topography was introduced as one of the 3D scanning tools to measure the air volume of clothing microclimate quantitatively. The purpose of this research is to adopt a non-contact image scanning technology, phase-shifting moiré topography, to ascertain relationship between air volume and insulation value of layered clothing systems in wear situations where the 2D fabric creates new conditions in 3D spaces. The insulation of vests over shirts as a layered clothing system was measured with a thermal manikin in the environmental condition of 20 degrees C, 65% RH and air velocity of 0.79 m/s. As the pattern size increased, the insulation of the clothing system was increased. But beyond a certain limit, the insulation started to decrease due to convection and ventilation, which is more apparent when only the vest was worn over the torso of manikin. The relationship between clothing air volume and insulation was difficult to predict with a single vest due to the extreme openings which induced active ventilation. But when the vest was worn over the shirt, the effects of thickness of the fabrics on insulation were less pronounced compared with that of air volume. In conclusion, phase-shifting moiré topography was one of the efficient and accurate ways of quantifying air volume and its distribution across the clothing microclimate. It is also noted that air volume becomes more crucial factor in predicting thermal insulation when clothing is layered.

  14. A fully automated non-external marker 4D-CT sorting algorithm using a serial cine scanning protocol.

    PubMed

    Carnes, Greg; Gaede, Stewart; Yu, Edward; Van Dyk, Jake; Battista, Jerry; Lee, Ting-Yim

    2009-04-07

    Current 4D-CT methods require external marker data to retrospectively sort image data and generate CT volumes. In this work we develop an automated 4D-CT sorting algorithm that performs without the aid of data collected from an external respiratory surrogate. The sorting algorithm requires an overlapping cine scan protocol. The overlapping protocol provides a spatial link between couch positions. Beginning with a starting scan position, images from the adjacent scan position (which spatial match the starting scan position) are selected by maximizing the normalized cross correlation (NCC) of the images at the overlapping slice position. The process was continued by 'daisy chaining' all couch positions using the selected images until an entire 3D volume was produced. The algorithm produced 16 phase volumes to complete a 4D-CT dataset. Additional 4D-CT datasets were also produced using external marker amplitude and phase angle sorting methods. The image quality of the volumes produced by the different methods was quantified by calculating the mean difference of the sorted overlapping slices from adjacent couch positions. The NCC sorted images showed a significant decrease in the mean difference (p < 0.01) for the five patients.

  15. Fluid shifts and endocrine responses during chair rest and water immersion in man

    NASA Technical Reports Server (NTRS)

    Greenleaf, J. E.; Shvartz, E.; Kravik, S.; Keil, L. C.

    1980-01-01

    The effects of external water pressure on intercompartmental fluid volume shifts and endocrine responses in man are investigated. Extracellular fluid volumes and plasma and urine electrolyte and endocrine responses of four male subjects were measured during eight hours of head-out water immersion and 16 hours of recovery bed rest and compared to responses obtained during eight hours of chair rest and 16 hours of bed rest without external hydrostatic pressure obtained in the same subjects five months later. Immersion is found to result in a substantial diuresis with respect to chair rest, accounted for by decreases in extracellular volume. A negative water balance during immersion and a positive water balance during chair rest were observed to be accompanied by a shift of extracellular volume to the intracellular compartment, as well as the suppression of plasma arginine vasopressin and renin activities in both regimes. The vasopressin and renin activity decreases are attributed to the increased central blood volume, and half of the plasma loss in immersed subjects is attributed to the effects of external water pressure.

  16. Piezoelectric and electromagnetic respiratory effort energy harvesters.

    PubMed

    Shahhaidar, Ehsaneh; Padasdao, Bryson; Romine, R; Stickley, C; Boric-Lubecke, Olga

    2013-01-01

    The movements of the torso due to normal breathing could be harvested as an alternative, and renewable power source for an ultra-low power electronic device. The same output signal could also be recorded as a physiological signal containing information about breathing, thus enabling self-powered wearable biosensors/harvesters. In this paper, the selection criteria for such a biosensor, optimization procedure, trade-offs, and challenges as a sensor and harvester are presented. The empirical data obtained from testing different modules on a mechanical torso and a human subject demonstrated that an electromagnetic generator could be used as an unobtrusive self-powered medical sensor by harvesting more power, offering reasonable amount of output voltage for rectification purposes, and detecting respiratory effort.

  17. Matroshka-R Phantom experiment

    NASA Image and Video Library

    2006-12-01

    ISS014-E-09097 (December 2006) --- European Space Agency (ESA) astronaut Thomas Reiter, Expedition 14 flight engineer, works with the European Matroshka-R Phantom experiment in the Zvezda Service Module of the International Space Station. Matroshka, the name for the traditional Russian set of nestling dolls, is an antroph-amorphous model of a human torso designed for radiation studies. The activity, supported by ground specialist tag-up, requires equipping the torso's individual horizontal slice-like layers with 356 thermo luminescent detectors (TLDs) and five nuclear radiation tracking detectors (NTDPs). The mannequin was then to be reassembled, covered with poncho and hood and installed in the Pirs Docking Compartment for studies of on-orbit radiation and long-term dose accumulation.

  18. Will weight loss cause significant dosimetric changes of target volumes and organs at risk in nasopharyngeal carcinoma treated with intensity-modulated radiation therapy?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Chuanben; Fei, Zhaodong; Chen, Lisha

    This study aimed to quantify dosimetric effects of weight loss for nasopharyngeal carcinoma (NPC) treated with intensity-modulated radiation therapy (IMRT). Overall, 25 patients with NPC treated with IMRT were enrolled. We simulated weight loss during IMRT on the computer. Weight loss model was based on the planning computed tomography (CT) images. The original external contour of head and neck was labeled plan 0, and its volume was regarded as pretreatment normal weight. We shrank the external contour with different margins (2, 3, and 5 mm) and generated new external contours of head and neck. The volumes of reconstructed external contoursmore » were regarded as weight during radiotherapy. After recontouring outlines, the initial treatment plan was mapped to the redefined CT scans with the same beam configurations, yielding new plans. The computer model represented a theoretical proportional weight loss of 3.4% to 13.7% during the course of IMRT. The dose delivered to the planning target volume (PTV) of primary gross tumor volume and clinical target volume significantly increased by 1.9% to 2.9% and 1.8% to 2.9% because of weight loss, respectively. The dose to the PTV of gross tumor volume of lymph nodes fluctuated from −2.0% to 1.0%. The dose to the brain stem and the spinal cord was increased (p < 0.001), whereas the dose to the parotid gland was decreased (p < 0.001). Weight loss may lead to significant dosimetric change during IMRT. Repeated scanning and replanning for patients with NPC with an obvious weight loss may be necessary.« less

  19. Continuous-wave dual-wavelength operation of a distributed feedback laser diode with an external cavity using a volume Bragg grating

    NASA Astrophysics Data System (ADS)

    Zheng, Yujin; Sekine, Takashi; Kurita, Takashi; Kato, Yoshinori; Kawashima, Toshiyuki

    2018-03-01

    We demonstrate continuous-wave dual-wavelength operation of a broad-area distributed feedback (DFB) laser diode with a single external-cavity configuration. This high-power DFB laser has a narrow bandwidth (<0.29 nm) and was used as a single-wavelength source. A volume Bragg grating was used as an output coupler for the external-cavity DFB laser to output another stable wavelength beam with a narrow bandwidth of 0.27 nm. A frequency difference for dual-wavelength operation of 0.88 THz was achieved and an output power of up to 415 mW was obtained. The external-cavity DFB laser showed a stable dual-wavelength operation over the practical current and temperature ranges.

  20. Impact of ballistic body armour and load carriage on walking patterns and perceived comfort.

    PubMed

    Park, Huiju; Branson, Donna; Petrova, Adriana; Peksoz, Semra; Jacobson, Bert; Warren, Aric; Goad, Carla; Kamenidis, Panagiotis

    2013-01-01

    This study investigated the impact of weight magnitude and distribution of body armour and carrying loads on military personnel's walking patterns and comfort perceptions. Spatio-temporal parameters of walking, plantar pressure and contact area were measured while seven healthy male right-handed military students wore seven different garments of varying weight (0.06, 9, 18 and 27 kg) and load distribution (balanced and unbalanced, on the front and back torso). Higher weight increased the foot contact time with the floor. In particular, weight placement on the non-dominant side of the front torso resulted in the greatest stance phase and double support. Increased plantar pressure and contact area observed during heavier loads entail increased impact forces, which can cause overuse injuries and foot blisters. Participants reported increasingly disagreeable pressure and strain in the shoulder, neck and lower back during heavier weight conditions and unnatural walking while wearing unbalanced weight distributed loads. This study shows the potentially synergistic impact of wearing body armour vest with differential loads on body movement and comfort perception. This study found that soldiers should balance loads, avoiding load placement on the non-dominant side front torso, thus minimising mobility restriction and potential injury risk. Implications for armour vest design modifications can also be found in the results.

  1. Thin and flexible active electrodes with shield for capacitive electrocardiogram measurement.

    PubMed

    Lee, Seung Min; Sim, Kyo Sik; Kim, Ko Keun; Lim, Yong Gyu; Park, Kwang Suk

    2010-05-01

    Capacitive electrocardiogram (ECG) measurement over clothing requires large electrodes that can remain in contact with curved body surfaces to increase the signal-to-noise ratio (SNR). In this article, we propose a new, thin, and flexible active electrode for use as a capacitive ECG measurement electrode. This electrode contains a shielding plate over its surface and it is extremely thin and can bend freely to cover larger body surfaces of the curve-shaped human torso. We evaluated the characteristics of flexible active electrodes under conditions of varying cloth thickness, electrode size, and contacting pressure. Electrodes of two sizes (45 and 12 cm(2)) were attached to a chest belt to measure the ECG from the human torso, and the results obtained for both the sizes were compared. Cloth thickness and electrode size showed a dominant effect on the SNR, whereas contacting pressure had almost no effect. The flexible active electrodes attached to chest belts wrapped closely and uniformly over the curved surface of the torso and SNR was increased with an increase in electrode size. Although the ECG signal became more distorted as the cloth thickness increased, the larger-sized flexible active electrode (45 cm(2)) showed less distortion than the smaller-sized one (12 cm(2)).

  2. Finding sacral: Developmental evolution of the axial skeleton of odontocetes (Cetacea).

    PubMed

    Buchholtz, Emily A; Gee, Jessica K

    2017-07-01

    Axial morphology was dramatically transformed during the transition from terrestrial to aquatic environments by archaeocete cetaceans, and again during the subsequent odontocete radiation. Here, we reconstruct the sequence of developmental events that underlie these phenotypic transitions. Archaeocete innovations include the loss of primaxial/abaxial interaction at the sacral/pelvic articulation and the modular dissociation of the fluke from the remainder of the tail. Odontocetes subsequently integrated lumbar, sacral, and anterior caudal vertebrae into a single torso module, and underwent multiple series-specific changes in vertebral count. The conservation of regional proportions despite regional fluctuations in count strongly argues that rates of somitogenesis can vary along the column and that segmentation was dissociated from regionalization during odontocete evolution. Conserved regional proportions also allow the prediction of the location and count of sacral homologs within the torso module. These predictions are tested with the analysis of comparative pudendal nerve root location and geometric morphometrics. We conclude that the proportion of the column represented by the sacral series has been conserved, and that its vertebrae have changed in count and relative centrum length in parallel with other torso vertebrae. Although the sacral series of odontocetes is de-differentiated, it is not de-regionalized. © 2017 Wiley Periodicals, Inc.

  3. Quantitative assessment of human body shape using Fourier analysis

    NASA Astrophysics Data System (ADS)

    Friess, Martin; Rohlf, F. J.; Hsiao, Hongwei

    2004-04-01

    Fall protection harnesses are commonly used to reduce the number and severity of injuries. Increasing the efficiency of harness design requires the size and shape variation of the user population to be assessed as detailed and as accurately as possible. In light of the unsatisfactory performance of traditional anthropometry with respect to such assessments, we propose the use of 3D laser surface scans of whole bodies and the statistical analysis of elliptic Fourier coefficients. Ninety-eight male and female adults were scanned. Key features of each torso were extracted as a 3D curve along front, back and the thighs. A 3D extension of Elliptic Fourier analysis4 was used to quantify their shape through multivariate statistics. Shape change as a function of size (allometry) was predicted by regressing the coefficients onto stature, weight and hip circumference. Upper and lower limits of torso shape variation were determined and can be used to redefine the design of the harness that will fit most individual body shapes. Observed allometric changes are used for adjustments to the harness shape in each size. Finally, the estimated outline data were used as templates for a free-form deformation of the complete torso surface using NURBS models (non-uniform rational B-splines).

  4. Evaluation of the iPhone with an acrylic sleeve versus the Scoliometer for rib hump measurement in scoliosis.

    PubMed

    Izatt, Maree T; Bateman, Gary R; Adam, Clayton J

    2012-07-30

    Vertebral rotation found in structural scoliosis contributes to trunkal asymmetry which is commonly measured with a simple Scoliometer device on a patient's thorax in the forward flexed position. The new generation of mobile 'smartphones' have an integrated accelerometer, making accurate angle measurement possible, which provides a potentially useful clinical tool for assessing rib hump deformity. This study aimed to compare rib hump angle measurements performed using a Smartphone and traditional Scoliometer on a set of plaster torsos representing the range of torsional deformities seen in clinical practice. Nine observers measured the rib hump found on eight plaster torsos moulded from scoliosis patients with both a Scoliometer and an Apple iPhone on separate occasions. Each observer repeated the measurements at least a week after the original measurements, and were blinded to previous results. Intra-observer reliability and inter-observer reliability were analysed using the method of Bland and Altman and 95% confidence intervals were calculated. The Intra-Class Correlation Coefficients (ICC) were calculated for repeated measurements of each of the eight plaster torso moulds by the nine observers. Mean absolute difference between pairs of iPhone/Scoliometer measurements was 2.1 degrees, with a small (1 degrees) bias toward higher rib hump angles with the iPhone. 95% confidence intervals for intra-observer variability were +/- 1.8 degrees (Scoliometer) and +/- 3.2 degrees (iPhone). 95% confidence intervals for inter-observer variability were +/- 4.9 degrees (iPhone) and +/- 3.8 degrees (Scoliometer). The measurement errors and confidence intervals found were similar to or better than the range of previously published thoracic rib hump measurement studies. The iPhone is a clinically equivalent rib hump measurement tool to the Scoliometer in spinal deformity patients. The novel use of plaster torsos as rib hump models avoids the variables of patient fatigue and discomfort, inconsistent positioning and deformity progression using human subjects in a single or multiple measurement sessions.

  5. Evaluation of the iPhone with an acrylic sleeve versus the Scoliometer for rib hump measurement in scoliosis

    PubMed Central

    2012-01-01

    Background Vertebral rotation found in structural scoliosis contributes to trunkal asymmetry which is commonly measured with a simple Scoliometer device on a patient's thorax in the forward flexed position. The new generation of mobile 'smartphones' have an integrated accelerometer, making accurate angle measurement possible, which provides a potentially useful clinical tool for assessing rib hump deformity. This study aimed to compare rib hump angle measurements performed using a Smartphone and traditional Scoliometer on a set of plaster torsos representing the range of torsional deformities seen in clinical practice. Methods Nine observers measured the rib hump found on eight plaster torsos moulded from scoliosis patients with both a Scoliometer and an Apple iPhone on separate occasions. Each observer repeated the measurements at least a week after the original measurements, and were blinded to previous results. Intra-observer reliability and inter-observer reliability were analysed using the method of Bland and Altman and 95% confidence intervals were calculated. The Intra-Class Correlation Coefficients (ICC) were calculated for repeated measurements of each of the eight plaster torso moulds by the nine observers. Results Mean absolute difference between pairs of iPhone/Scoliometer measurements was 2.1 degrees, with a small (1 degrees) bias toward higher rib hump angles with the iPhone. 95% confidence intervals for intra-observer variability were +/- 1.8 degrees (Scoliometer) and +/- 3.2 degrees (iPhone). 95% confidence intervals for inter-observer variability were +/- 4.9 degrees (iPhone) and +/- 3.8 degrees (Scoliometer). The measurement errors and confidence intervals found were similar to or better than the range of previously published thoracic rib hump measurement studies. Conclusions The iPhone is a clinically equivalent rib hump measurement tool to the Scoliometer in spinal deformity patients. The novel use of plaster torsos as rib hump models avoids the variables of patient fatigue and discomfort, inconsistent positioning and deformity progression using human subjects in a single or multiple measurement sessions. PMID:22846346

  6. A Comparison of 2 Practical Cooling Methods on Cycling Capacity in the Heat

    PubMed Central

    Cuttell, Saul A.; Kiri, Victor; Tyler, Christopher

    2016-01-01

    Context:  Cooling the torso and neck can improve exercise performance and capacity in a hot environment; however, the proposed mechanisms for the improvements often differ. Objective:  To directly compare the effects of cooling the neck and torso region using commercially available devices on exercise capacity in a hot environment (temperature = 35°C ± 0.1°C, relative humidity = 50.1% ± 0.7%). Design:  Crossover study. Setting:  Laboratory. Patients or Other Participants:  Eight recreationally active, nonheat-acclimated men (age = 24 ± 4 years, height = 1.82 ± 0.10 m, mass = 80.3 ± 9.7 kg, maximal power output = 240 ± 25 W). Intervention(s):  Three cycling capacity tests at 60% maximal power output to volitional exhaustion: 1 with no cooling (NC), 1 with vest cooling (VC), and 1 with a neck cooling collar (CC). Main Outcome Measure(s):  Time to volitional exhaustion, rectal temperature, mean skin temperature, torso and neck skin temperature, body mass, heart rate, rating of perceived exertion, thermal sensation, and feeling scale were measured. Results:  Participants cycled longer with VC (32.2 ± 9.5 minutes) than NC (27. 6 ± 7.6 minutes; P = .03; d = 0.54) or CC (30.0 ± 8.8 minutes; P = .02; d = 0.24). We observed no difference between NC and CC (P = .12; d = 0.31). Neck and torso temperature and perceived thermal sensation were reduced with the use of cooling modalities (P < .001), but no other variables were affected. Conclusions:  Cycling capacity in the heat improved when participants used a commercially available cooling vest, but we observed no benefit from wearing a commercially available CC. The vest and the collar did not alter the heart rate, rectal temperature, skin temperature, or sweat-loss responses to the cycling bout. PMID:27571045

  7. The influence of whole-body vs. torso pre-cooling on physiological strain and performance of high-intensity exercise in the heat.

    PubMed

    Sleivert, G G; Cotter, J D; Roberts, W S; Febbraio, M A

    2001-04-01

    Little research has been reported examining the effects of pre-cooling on high-intensity exercise performance, particularly when combined with strategies to keep the working muscle warm. This study used nine active males to determine the effects of pre-cooling the torso and thighs (LC), pre-cooling the torso (ice-vest in 3 degrees C air) while keeping the thighs warm (LW), or no cooling (CON: 31 degrees C air), on physiological strain and high-intensity (45-s) exercise performance (33 degrees C, 60% rh). Furthermore, we sought to determine whether performance after pre-cooling was influenced by a short exercise warm-up. The 45-s test was performed at different (P<0.05) mean core temperature [(rectal+oesophageal)/2] [CON: 37.3+/-0.3 (S.D.), LW: 37.1+/-0.3, LC: 36.8+/-0.4 degrees C] and mean skin temperature (CON: 34.6+/-0.6, LW: 29.0+/-1.0, LC: 27.2+/-1.2 degrees C) between all conditions. Forearm blood flow prior to exercise was also lower in LC (3.1+/-2.0 ml 100 ml tissue(-1) x min(-1)) than CON (8.2+/-2.5, P=0.01) but not LW (4.3+/-2.6, P=0.46). After an exercise warm-up, muscle temperature (Tm) was not significantly different between conditions (CON: 37.3+/-1.5, LW: 37.3+/-1.2, LC: 36.6+/-0.7 degrees C, P=0.16) but when warm-up was excluded, T(m) was lower in LC (34.5+/-1.9 degrees C, P=0.02) than in CON (37.3+/-1.0) and LW (37.1+/-0.9). Even when a warm-up was performed, torso+thigh pre-cooling decreased both peak (-3.4+/-3.8%, P=0.04) and mean power output (-4.1+/-3.8%, P=0.01) relative to the control, but this effect was markedly larger when warm-up was excluded (peak power -7.7+/-2.5%, P=0.01; mean power -7.6+/-1.2%, P=0.01). Torso-only pre-cooling did not reduce peak or mean power, either with or without warm-up. These data indicate that pre-cooling does not improve 45-s high-intensity exercise performance, and can impair performance if the working muscles are cooled. A short exercise warm-up largely removes any detrimental effects of a cold muscle on performance by increasing Tm.

  8. External stent for repair of secondary tracheomalacia.

    PubMed

    Johnston, M R; Loeber, N; Hillyer, P; Stephenson, L W; Edmunds, L H

    1980-09-01

    Tracheomalacia was created in anesthetized piglets by submucosal resection of 3 to 5 tracheal cartilages. Measurements of airway pressure and flow showed that expiratory airway resistance is maximal at low lung volumes and is significantly increased by creation of the malacic segment. Cervical flexion increases expiratory airway resistance, whereas hyperextension of the neck reduces resistance toward normal. External stenting of the malacic segment reduces expiratory airway resistance, and the combination of external stenting and hyperextension restores airway resistance to normal except at low lung volume. Two patients with secondary tracheomalacia required tracheostomy and could not be decannulated after the indication for the tracheostomy was corrected. Both were successfully decannulated after external stenting of the malacic segment with rib grafts. Postoperative measurements of expiratory pulmonary resistance show a marked decrease from preoperative measurements. External stenting of symptomatic tracheomalacia reduces expiratory airway resistance by supporting and stretching the malacic segment and is preferable to prolonged internal stenting or tracheal resection.

  9. Full-Scale Crash Test of an MD-500 Helicopter

    NASA Technical Reports Server (NTRS)

    Littell, Justin

    2011-01-01

    A full-scale crash test was successfully conducted in March 2010 of an MD-500 helicopter at NASA Langley Research Center s Landing and Impact Research Facility. The reasons for conducting this test were threefold: 1 To generate data to be used with finite element computer modeling efforts, 2 To study the crashworthiness features typically associated with a small representative helicopter, and 3 To compare aircraft response to data collected from a previously conducted MD-500 crash test, which included an externally deployable energy absorbing (DEA) concept. Instrumentation on the airframe included accelerometers on various structural components of the airframe; and strain gages on keel beams, skid gear and portions of the skin. Three Anthropomorphic Test Devices and a specialized Human Surrogate Torso Model were also onboard to collect occupant loads for evaluation with common injury risk criteria. This paper presents background and results from this crash test conducted without the DEA concept. These results showed accelerations of approximately 30 to 50 g on the airframe at various locations, little energy attenuation through the airframe, and moderate to high probability of occupant injury for a variety of injury criteria.

  10. NOTE: Solving the ECG forward problem by means of a meshless finite element method

    NASA Astrophysics Data System (ADS)

    Li, Z. S.; Zhu, S. A.; He, Bin

    2007-07-01

    The conventional numerical computational techniques such as the finite element method (FEM) and the boundary element method (BEM) require laborious and time-consuming model meshing. The new meshless FEM only uses the boundary description and the node distribution and no meshing of the model is required. This paper presents the fundamentals and implementation of meshless FEM and the meshless FEM method is adapted to solve the electrocardiography (ECG) forward problem. The method is evaluated on a single-layer torso model, in which the analytical solution exists, and tested in a realistic geometry homogeneous torso model, with satisfactory results being obtained. The present results suggest that the meshless FEM may provide an alternative for ECG forward solutions.

  11. Extravehicular Activity (EVA) 101: Constellation EVA Systems

    NASA Technical Reports Server (NTRS)

    Jordan, Nicole C.

    2007-01-01

    A viewgraph presentation on Extravehicular Activity (EVA) Systems is shown. The topics include: 1) Why do we need space suits? 2) Protection From the Environment; 3) Primary Life Support System (PLSS); 4) Thermal Control; 5) Communications; 6) Helmet and Extravehicular Visor Assy; 7) Hard Upper Torso (HUT) and Arm Assy; 8) Display and Controls Module (DCM); 9) Gloves; 10) Lower Torso Assembly (LTA); 11) What Size Do You Need?; 12) Boot and Sizing Insert; 13) Boot Heel Clip and Foot Restraint; 14) Advanced and Crew Escape Suit; 15) Nominal & Off-Nominal Landing; 16) Gemini Program (mid-1960s); 17) Apollo EVA on Service Module; 18) A Bold Vision for Space Exploration, Authorized by Congress; 19) EVA System Missions; 20) Configurations; 21) Reduced Gravity Program; and 22) Other Opportunities.

  12. 3-D breast anthropometry of plus-sized women in South Africa.

    PubMed

    Pandarum, Reena; Yu, Winnie; Hunter, Lawrance

    2011-09-01

    Exploratory retail studies in South Africa indicate that plus-sized women experience problems and dissatisfaction with poorly fitting bras. The lack of 3-D anthropometric studies for the plus-size women's bra market initiated this research. 3-D body torso measurements were collected from a convenience sample of 176 plus-sized women in South Africa. 3-D breast measurements extracted from the TC(2) NX12-3-D body scanner 'breast module' software were compared with traditional tape measurements. Regression equations show that the two methods of measurement were highly correlated although, on average, the bra cup size determining factor 'bust minus underbust' obtained from the 3-D method is approximately 11% smaller than that of the manual method. It was concluded that the total bust volume correlated with the quadrant volume (r = 0.81), cup length, bust length and bust prominence, should be selected as the overall measure of bust size and not the traditional bust girth and the underbust measurement. STATEMENT OF RELEVANCE: This study contributes new data and adds to the knowledge base of anthropometry and consumer ergonomics on bra fit and support, published in this, the Ergonomics Journal, by Chen et al. (2010) on bra fit and White et al. (2009) on breast support during overground running.

  13. Epicardial potentials computed from the body surface potential map using inverse electrocardiography and an individualised torso model improve sensitivity for acute myocardial infarction diagnosis.

    PubMed

    Daly, Michael J; Finlay, Dewar D; Guldenring, Daniel; Bond, Raymond R; McCann, Aaron J; Scott, Peter J; Adgey, Jennifer A; Harbinson, Mark T

    2017-12-01

    Epicardial potentials (EPs) derived from the body surface potential map (BSPM) improve acute myocardial infarction (AMI) diagnosis. In this study, we compared EPs derived from the 80-lead BSPM using a standard thoracic volume conductor model (TVCM) with those derived using a patient-specific torso model (PSTM) based on body mass index (BMI). Consecutive patients presenting to both the emergency department and pre-hospital coronary care unit between August 2009 and August 2011 with acute ischaemic-type chest pain at rest were enrolled. At first medical contact, 12-lead electrocardiograms and BSPMs were recorded. The BMI for each patient was calculated. Cardiac troponin T (cTnT) was sampled 12 hours after symptom onset. Patients were excluded from analysis if they had any ECG confounders to interpretation of the ST-segment. A cardiologist assessed the 12-lead ECG for ST-segment elevation myocardial infarction by Minnesota criteria and the BSPM. BSPM ST-elevation (STE) was ⩾0.2 mV in anterior, ⩾0.1 mV in lateral, inferior, right ventricular or high right anterior and ⩾0.05 mV in posterior territories. To derive EPs, the BSPM data were interpolated to yield values at 352 nodes of a Dalhousie torso. Using an inverse solution based on the boundary element method, EPs at 98 cardiac nodes positioned within a standard TVCM were derived. The TVCM was then scaled to produce a PSTM using a model developed from computed tomography in 48 patients of varying BMIs, and EPs were recalculated. EPs >0.3 mV defined STE. A cardiologist blinded to both the 12-lead ECG and BSPM interpreted the EP map. AMI was defined as cTnT ⩾0.1 µg/L. Enrolled were 400 patients (age 62 ± 13 years; 57% male); 80 patients had exclusion criteria. Of the remaining 320 patients, the BMI was an average of 27.8 ± 5.6 kg/m 2 . Of these, 180 (56%) had AMI. Overall, 132 had Minnesota STE on ECG (sensitivity 65%, specificity 89%) and 160 had BSPM STE (sensitivity 81%, specificity 90%). EP STE occurred in 165 patients using TVCM (sensitivity 88%, specificity 95%; p < 0.001) and in 206 patients using PSTM (sensitivity 98%, specificity 79%; p < 0.001). Of those with AMI by cTnT and EPs ⩽0.3 mV using TVCM ( n = 22), 18 (82%) patients had EPs >0.3 mV when an individualised PSTM was used. Among patients presenting with ischaemic-type chest pain at rest, EPs derived from BSPM using a novel PSTM significantly improve sensitivity for AMI diagnosis.

  14. SU-E-T-540: Volumetric Modulated Total Body Irradiation Using a Rotational Lazy Susan-Like Immobilization System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gu, X; Hrycushko, B; Lee, H

    2014-06-01

    Purpose: Traditional extended SSD total body irradiation (TBI) techniques can be problematic in terms of patient comfort and/or dose uniformity. This work aims to develop a comfortable TBI technique that achieves a uniform dose distribution to the total body while reducing the dose to organs at risk for complications. Methods: To maximize patient comfort, a lazy Susan-like couch top immobilization system which rotates about a pivot point was developed. During CT simulation, a patient is immobilized by a Vac-Lok bag within the body frame. The patient is scanned head-first and then feet-first following 180° rotation of the frame. The twomore » scans are imported into the Pinnacle treatment planning system and concatenated to give a full-body CT dataset. Treatment planning matches multiple isocenter volumetric modulated arc (VMAT) fields of the upper body and multiple isocenter parallel-opposed fields of the lower body. VMAT fields of the torso are optimized to satisfy lung dose constraints while achieving a therapeutic dose to the torso. The multiple isocenter VMAT fields are delivered with an indexed couch, followed by body frame rotation about the pivot point to treat the lower body isocenters. The treatment workflow was simulated with a Rando phantom, and the plan was mapped to a solid water slab phantom for point- and film-dose measurements at multiple locations. Results: The treatment plan of 12Gy over 8 fractions achieved 80.2% coverage of the total body volume within ±10% of the prescription dose. The mean lung dose was 8.1 Gy. All ion chamber measurements were within ±1.7% compared to the calculated point doses. All relative film dosimetry showed at least a 98.0% gamma passing rate using a 3mm/3% passing criteria. Conclusion: The proposed patient comfort-oriented TBI technique provides for a uniform dose distribution within the total body while reducing the dose to the lungs.« less

  15. Human body surface area: measurement and prediction using three dimensional body scans.

    PubMed

    Tikuisis, P; Meunier, P; Jubenville, C E

    2001-08-01

    The development of three dimensional laser scanning technology and sophisticated graphics editing software have allowed an alternative and potentially more accurate determination of body surface area (BSA). Raw whole-body scans of 641 adults (395 men and 246 women) were obtained from the anthropometric data base of the Civilian American and European Surface Anthropometry Resource project. Following surface restoration of the scans (i.e. patching and smoothing), BSA was calculated. A representative subset of the entire sample population involving 12 men and 12 women (G24) was selected for detailed measurements of hand surface area (SAhand) and ratios of surface area to volume (SA/VOL) of various body segments. Regression equations involving wrist circumference and arm length were used to predict SAhand of the remaining population. The overall [mean (SD)] of BSA were 2.03 (0.19) and 1.73 (0.19) m2 for men and women, respectively. Various prediction equations were tested and although most predicted the measured BSA reasonably closely, residual analysis revealed an overprediction with increasing body size in most cases. Separate non-linear regressions for each sex yielded the following best-fit equations (with root mean square errors of about 1.3%): BSA (cm2) = 128.1 x m0.44 x h0.60 for men and BSA = 147.4 x m0.47 x h0.55 for women, where m, body mass, is in kilograms and h, height, is in centimetres. The SA/VOL ratios of the various body segments were higher for the women compared to the men of G24, significantly for the head plus neck (by 7%), torso (19%), upper arms (15%), forearms (20%), hands (18%), and feet (11%). The SA/VOL for both sexes ranged from approximately 12.m-1 for the pelvic region to 104-123.m-1 for the hands, and shape differences were a factor for the torso and lower leg.

  16. Comparison of organ dose and dose equivalent using ray tracing of male and female Voxel phantoms to space flight phantom torso data

    NASA Astrophysics Data System (ADS)

    Kim, Myung-Hee; Qualls, Garry; Slaba, Tony; Cucinotta, Francis A.

    Phantom torso experiments have been flown on the space shuttle and International Space Station (ISS) providing validation data for radiation transport models of organ dose and dose equivalents. We describe results for space radiation organ doses using a new human geometry model based on detailed Voxel phantoms models denoted for males and females as MAX (Male Adult voXel) and Fax (Female Adult voXel), respectively. These models represent the human body with much higher fidelity than the CAMERA model currently used at NASA. The MAX and FAX models were implemented for the evaluation of directional body shielding mass for over 1500 target points of major organs. Radiation exposure to solar particle events (SPE), trapped protons, and galactic cosmic rays (GCR) were assessed at each specific site in the human body by coupling space radiation transport models with the detailed body shielding mass of MAX/FAX phantom. The development of multiple-point body-shielding distributions at each organ site made it possible to estimate the mean and variance of space dose equivalents at the specific organ. For the estimate of doses to the blood forming organs (BFOs), active marrow distributions in adult were accounted at bone marrow sites over the human body. We compared the current model results to space shuttle and ISS phantom torso experiments and to calculations using the CAMERA model.

  17. Comparison of Organ Dose and Dose Equivalent Using Ray Tracing of Male and Female Voxel Phantoms to Space Flight Phantom Torso Data

    NASA Technical Reports Server (NTRS)

    Kim, Myung-Hee Y.; Qualls, Garry D.; Cucinotta, Francis A.

    2008-01-01

    Phantom torso experiments have been flown on the space shuttle and International Space Station (ISS) providing validation data for radiation transport models of organ dose and dose equivalents. We describe results for space radiation organ doses using a new human geometry model based on detailed Voxel phantoms models denoted for males and females as MAX (Male Adult voXel) and Fax (Female Adult voXel), respectively. These models represent the human body with much higher fidelity than the CAMERA model currently used at NASA. The MAX and FAX models were implemented for the evaluation of directional body shielding mass for over 1500 target points of major organs. Radiation exposure to solar particle events (SPE), trapped protons, and galactic cosmic rays (GCR) were assessed at each specific site in the human body by coupling space radiation transport models with the detailed body shielding mass of MAX/FAX phantom. The development of multiple-point body-shielding distributions at each organ site made it possible to estimate the mean and variance of space dose equivalents at the specific organ. For the estimate of doses to the blood forming organs (BFOs), active marrow distributions in adult were accounted at bone marrow sites over the human body. We compared the current model results to space shuttle and ISS phantom torso experiments and to calculations using the CAMERA model.

  18. Rotational biomechanics of the elite golf swing: benchmarks for amateurs.

    PubMed

    Meister, David W; Ladd, Amy L; Butler, Erin E; Zhao, Betty; Rogers, Andrew P; Ray, Conrad J; Rose, Jessica

    2011-08-01

    The purpose of this study was to determine biomechanical factors that may influence golf swing power generation. Three-dimensional kinematics and kinetics were examined in 10 professional and 5 amateur male golfers. Upper-torso rotation, pelvic rotation, X-factor (relative hip-shoulder rotation), O-factor (pelvic obliquity), S-factor (shoulder obliquity), and normalized free moment were assessed in relation to clubhead speed at impact (CSI). Among professional golfers, results revealed that peak free moment per kilogram, peak X-factor, and peak S-factor were highly consistent, with coefficients of variation of 6.8%, 7.4%, and 8.4%, respectively. Downswing was initiated by reversal of pelvic rotation, followed by reversal of upper-torso rotation. Peak X-factor preceded peak free moment in all swings for all golfers, and occurred during initial downswing. Peak free moment per kilogram, X-factor at impact, peak X-factor, and peak upper-torso rotation were highly correlated to CSI (median correlation coefficients of 0.943, 0.943, 0.900, and 0.900, respectively). Benchmark curves revealed kinematic and kinetic temporal and spatial differences of amateurs compared with professional golfers. For amateurs, the number of factors that fell outside 1-2 standard deviations of professional means increased with handicap. This study identified biomechanical factors highly correlated to golf swing power generation and may provide a basis for strategic training and injury prevention.

  19. Specificity of postural sway to the demands of a precision task at sea.

    PubMed

    Chen, Fu-Chen; Stoffregen, Thomas A

    2012-06-01

    Mariners actively adjust their body orientation in response to ship motion. On a ship at sea, we evaluated relations between standing postural activity and the performance of a precision aiming task. Standing participants (experienced mariners) maintained the beam from a handheld laser on a target. Targets were large or small, thereby varying the difficulty of the aiming task. Targets were located in front of the participant or to the participant's right (requiring participants to look over the right shoulder), thereby varying the functional consequences (for the aiming task) of postural activity in different body axes. The torso was oriented toward the bow or toward the ship's side (athwartship), thereby varying the effects on postural activity of differential motion of the ship in its different axes. The weather was rough, producing high magnitudes of ship motion, which sometimes caused participants to step or stagger. Our manipulations influenced the magnitude and dynamics of head and torso movements, as well as the organization of movement in different axes. The results provide the first empirical confirmation that postural activity can be influenced by orientation of the torso relative to a ship. Despite powerful effects of ship motion, postural activity was influenced by variations in target location and in the difficulty of the aiming task, replicating subtle effects that have been observed on land. We discuss implications for hull design and the placement of workstations on ships.

  20. Frontal slab composite magnetic resonance neurography of the brachial plexus: implications for infraclavicular block approaches.

    PubMed

    Raphael, David T; McIntee, Diane; Tsuruda, Jay S; Colletti, Patrick; Tatevossian, Ray

    2005-12-01

    Magnetic resonance neurography (MRN) is an imaging method by which nerves can be selectively highlighted. Using commercial software, the authors explored a variety of approaches to develop a three-dimensional volume-rendered MRN image of the entire brachial plexus and used it to evaluate the accuracy of infraclavicular block approaches. With institutional review board approval, MRN of the brachial plexus was performed in 10 volunteer subjects. MRN imaging was performed on a GE 1.5-tesla magnetic resonance scanner (General Electric Healthcare Technologies, Waukesha, WI) using a phased array torso coil. Coronal STIR and T1 oblique sagittal sequences of the brachial plexus were obtained. Multiple software programs were explored for enhanced display and manipulation of the composite magnetic resonance images. The authors developed a frontal slab composite approach that allows single-frame reconstruction of a three-dimensional volume-rendered image of the entire brachial plexus. Automatic segmentation was supplemented by manual segmentation in nearly all cases. For each of three infraclavicular approaches (posteriorly directed needle below midclavicle, infracoracoid, or caudomedial to coracoid), the targeting error was measured as the distance from the MRN plexus midpoint to the approach-targeted site. Composite frontal slabs (coronal views), which are single-frame three-dimensional volume renderings from image-enhanced two-dimensional frontal view projections of the underlying coronal slices, were created. The targeting errors (mean +/- SD) for the approaches-midclavicle, infracoracoid, caudomedial to coracoid-were 0.43 +/- 0.67, 0.99 +/- 1.22, and 0.65 +/- 1.14 cm, respectively. Image-processed three-dimensional volume-rendered MNR scans, which allow visualization of the entire brachial plexus within a single composite image, have educational value in illustrating the complexity and individual variation of the plexus. Suggestions for improved guidance during infraclavicular block procedures are presented.

  1. Quantitative Prediction of Stone Fragility From Routine Dual Energy CT: Ex vivo proof of Feasibility.

    PubMed

    Ferrero, Andrea; Montoya, Juan C; Vaughan, Lisa E; Huang, Alice E; McKeag, Ian O; Enders, Felicity T; Williams, James C; McCollough, Cynthia H

    2016-12-01

    Previous studies have demonstrated a qualitative relationship between stone fragility and internal stone morphology. The goal of this study was to quantify morphologic features from dual-energy computed tomography (CT) images and assess their relationship to stone fragility. Thirty-three calcified urinary stones were scanned with micro-CT. Next, they were placed within torso-shaped water phantoms and scanned with the dual-energy CT stone composition protocol in routine use at our institution. Mixed low- and high-energy images were used to measure volume, surface roughness, and 12 metrics describing internal morphology for each stone. The ratios of low- to high-energy CT numbers were also measured. Subsequent to imaging, stone fragility was measured by disintegrating each stone in a controlled ex vivo experiment using an ultrasonic lithotripter and recording the time to comminution. A multivariable linear regression model was developed to predict time to comminution. The average stone volume was 300 mm 3 (range: 134-674 mm 3 ). The average comminution time measured ex vivo was 32 seconds (range: 7-115 seconds). Stone volume, dual-energy CT number ratio, and surface roughness were found to have the best combined predictive ability to estimate comminution time (adjusted R 2  = 0.58). The predictive ability of mixed dual-energy CT images, without use of the dual-energy CT number ratio, to estimate comminution time was slightly inferior, with an adjusted R 2 of 0.54. Dual-energy CT number ratios, volume, and morphologic metrics may provide a method for predicting stone fragility, as measured by time to comminution from ultrasonic lithotripsy. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  2. Quantitative prediction of stone fragility from routine single and dual energy CT: proof of feasibility

    PubMed Central

    Ferrero, Andrea; Montoya, Juan C.; Vaughan, Lisa E.; Huang, Alice E.; McKeag, Ian O.; Enders, Felicity T.; Williams, James C.; McCollough, Cynthia H.

    2016-01-01

    Rationale and Objectives Previous studies have demonstrated a qualitative relationship between stone fragility and internal stone morphology. The goal of this study was to quantify morphological features from dual-energy CT images and assess their relationship to stone fragility. Materials and Methods Thirty-three calcified urinary stones were scanned with micro CT. Next, they were placed within torso-shaped water phantoms and scanned with the dual-energy CT stone composition protocol in routine use at our institution. Mixed low-and high-energy images were used to measure volume, surface roughness, and 12 metrics describing internal morphology for each stone. The ratios of low- to high-energy CT numbers were also measured. Subsequent to imaging, stone fragility was measured by disintegrating each stone in a controlled ex vivo experiment using an ultrasonic lithotripter and recording the time to comminution. A multivariable linear regression model was developed to predict time to comminution. Results The average stone volume was 300 mm3 (range 134–674 mm3). The average comminution time measured ex vivo was 32 s (range 7–115 s). Stone volume, dual-energy CT number ratio and surface roughness were found to have the best combined predictive ability to estimate comminution time (adjusted R2= 0.58). The predictive ability of mixed dual-energy CT images, without use of the dual-energy CT number ratio, to estimate comminution time was slightly inferior, with an adjusted R2 of 0.54. Conclusion Dual-energy CT number ratios, volume, and morphological metrics may provide a method for predicting stone fragility, as measured by time to comminution from ultrasonic lithotripsy. PMID:27717761

  3. 14 CFR 25.801 - Ditching.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... considered as buoyancy volume. (e) Unless the effects of the collapse of external doors and windows are... prescribed in paragraphs (c) and (d) of this section), the external doors and windows must be designed to...

  4. A contactless approach for respiratory gating in PET using continuous-wave radar

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ersepke, Thomas, E-mail: Thomas.Ersepke@rub.de; Büther, Florian; Heß, Mirco

    Purpose: Respiratory gating is commonly used to reduce motion artifacts in positron emission tomography (PET). Clinically established methods for respiratory gating in PET require contact to the patient or a direct optical line between the sensor and the patient’s torso and time consuming preparation. In this work, a contactless method for capturing a respiratory signal during PET is presented based on continuous-wave radar. Methods: The proposed method relies on the principle of emitting an electromagnetic wave and detecting the phase shift of the reflected wave, modulated due to the respiratory movement of the patient’s torso. A 24 GHz carrier frequencymore » was chosen allowing wave propagation through plastic and clothing with high reflections at the skin surface. A detector module and signal processing algorithms were developed to extract a quantitative respiratory signal. The sensor was validated using a high precision linear table. During volunteer measurements and [{sup 18}F] FDG PET scans, the radar sensor was positioned inside the scanner bore of a PET/computed tomography scanner. As reference, pressure belt (one volunteer), depth camera-based (two volunteers, two patients), and PET data-driven (six patients) signals were acquired simultaneously and the signal correlation was quantified. Results: The developed system demonstrated a high measurement accuracy for movement detection within the submillimeter range. With the proposed method, small displacements of 25 μm could be detected, not considerably influenced by clothing or blankets. From the patient studies, the extracted respiratory radar signals revealed high correlation (Pearson correlation coefficient) to those derived from the external pressure belt and depth camera signals (r = 0.69–0.99) and moderate correlation to those of the internal data-driven signals (r = 0.53–0.70). In some cases, a cardiac signal could be visualized, due to the representation of the mechanical heart motion on the skin. Conclusions: Accurate respiratory signals were obtained successfully by the proposed method with high spatial and temporal resolution. By working without contact and passing through clothing and blankets, this approach minimizes preparation time and increases the convenience of the patient during the scan.« less

  5. Sweating responses during heat acclimation and moderate conditioning

    NASA Technical Reports Server (NTRS)

    Shvartz, E.; Bhattacharya, A.; Sperinde, S. J.; Brock, P. J.; Sciaraffa, D.; Van Beaumont, W.

    1979-01-01

    Experiments were conducted on ten young male subjects to determine sweating onset, distribution, and patterns as well as the relationships of these responses to body temperature during heat acclimation and moderate conditioning performed in temperate (24 C) conditions. The subjects are randomly assigned to two groups of five subjects each. The experimental period consisted of eight successive days of either graded exercise to exhaustion on a bicycle ergometer in heat (acclimation group) or in a temperate environment (control group). Major conclusions are that (1) acclimation and conditioning result in relatively more sweat rate on the limbs than on the torso, but that these changes are less related to body temperature than torso sweat rate; and (2) sweating sensitivity increases during acclimation and conditioning, but its contribution to heat acclimation is minor.

  6. Loosely coupled coaxial TEM applicators for deep-heating.

    PubMed

    Harrison, W H; Storm, F K

    1989-01-01

    The development of a coaxial TEM (transverse electromagnetic) deep-heating, non-contacting applicator employing two axially spaced concentric sleeves is described which has electrostatic characteristics and has been named the ESA. Thermal data obtained with the FDA/CDRH elliptic-shaped human torso phantom (with fat overlay) showed nearly uniform heating (+/- 10%) throughout the inner cross-section. Saline tank measurements on a torso cross-section confirmed similar SAR uniformity. Animal experiments with a pig, both with and without blood flow, verified deep-heating and suggested that some preferential central heating occurred. The absence of excessive surface heating indicated that the major portion of the E-field excitation is axially aligned. The non-contacting applicator does not require a water bolus, and experiments showed that moderate patient movement had minor effect on performance.

  7. Coherent addition of high power broad-area laser diodes with a compact VBG V-shaped external Talbot cavity

    DOE PAGES

    Liu, Bo; Braiman, Yehuda

    2018-02-06

    In this paper, we introduced a compact V-shaped external Talbot cavity for phase locking of high power broad-area laser diodes. The length of compact cavity is ~25 mm. Near diffraction-limit coherent addition of 10 broad-area laser diodes indicated that high quality phase locking was achieved. We measured the near-field emission mode of each individual broad-area laser diode with different feedback, such as a volume Bragg grating and a high reflection mirror. Finally, we found out that the best result of phase locking broad-area laser diodes was achieved by the compact V-shaped external Talbot cavity with volume Bragg grating feedback.

  8. Coherent addition of high power broad-area laser diodes with a compact VBG V-shaped external Talbot cavity

    NASA Astrophysics Data System (ADS)

    Liu, Bo; Braiman, Yehuda

    2018-05-01

    We introduced a compact V-shaped external Talbot cavity for phase locking of high power broad-area laser diodes. The length of compact cavity is ∼25 mm. Near diffraction-limit coherent addition of 10 broad-area laser diodes indicated that high quality phase locking was achieved. We measured the near-field emission mode of each individual broad-area laser diode with different feedback, such as a volume Bragg grating and a high reflection mirror. We found out that the best result of phase locking broad-area laser diodes was achieved by the compact V-shaped external Talbot cavity with volume Bragg grating feedback.

  9. Coherent addition of high power broad-area laser diodes with a compact VBG V-shaped external Talbot cavity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Bo; Braiman, Yehuda

    In this paper, we introduced a compact V-shaped external Talbot cavity for phase locking of high power broad-area laser diodes. The length of compact cavity is ~25 mm. Near diffraction-limit coherent addition of 10 broad-area laser diodes indicated that high quality phase locking was achieved. We measured the near-field emission mode of each individual broad-area laser diode with different feedback, such as a volume Bragg grating and a high reflection mirror. Finally, we found out that the best result of phase locking broad-area laser diodes was achieved by the compact V-shaped external Talbot cavity with volume Bragg grating feedback.

  10. Robonaut 2 - Building a Robot on the International Space Station

    NASA Technical Reports Server (NTRS)

    Diftler, Myron; Badger, Julia; Joyce, Charles; Potter, Elliott; Pike, Leah

    2015-01-01

    In 2010, the Robonaut Project embarked on a multi-phase mission to perform technology demonstrations on-board the International Space Station (ISS), showcasing state of the art robotics technologies through the use of Robonaut 2 (R2). This phased approach implements a strategy that allows for the use of ISS as a test bed during early development to both demonstrate capability and test technology while still making advancements in the earth based laboratories for future testing and operations in space. While R2 was performing experimental trials onboard the ISS during the first phase, engineers were actively designing for Phase 2, Intra-Vehicular Activity (IVA) Mobility, that utilizes a set of zero-g climbing legs outfitted with grippers to grasp handrails and seat tracks. In addition to affixing the new climbing legs to the existing R2 torso, it became clear that upgrades to the torso to both physically accommodate the climbing legs and to expand processing power and capabilities of the robot were required. In addition to these upgrades, a new safety architecture was also implemented in order to account for the expanded capabilities of the robot. The IVA climbing legs not only needed to attach structurally to the R2 torso on ISS, but also required power and data connections that did not exist in the upper body. The climbing legs were outfitted with a blind mate adapter and coarse alignment guides for easy installation, but the upper body required extensive rewiring to accommodate the power and data connections. This was achieved by mounting a custom adapter plate to the torso and routing the additional wiring through the waist joint to connect to the new set of processors. In addition to the power and data channels, the integrated unit also required updated electronics boards, additional sensors and updated processors to accommodate a new operating system, software platform, and custom control system. In order to perform the unprecedented task of building a robot in space, extensive practice sessions and meticulous procedures were required. Since crew training time is at a premium, the R2 team took a skills-based training approach to ensure the astronauts were proficient with a basic skill set while refining the detailed procedures over several practice sessions and simulations. In addition to the crew activities, meticulous ground procedures were required in order to upgrade firmware on the upper body motor drivers. The new firmware for the IVA mobility unit needed to be deployed using the old software system. This also provided an opportunity to upgrade the upper body joints with new software and allowed for limited insight into the success of the updates. Complete verification that the updated firmware was successfully loaded was not confirmed until the rewiring of the upper body torso was complete.

  11. Biomechanics of Sports-Induced Axial-Compression Injuries of the Neck

    PubMed Central

    Ivancic, Paul C.

    2012-01-01

    Context Head-first sports-induced impacts cause cervical fractures and dislocations and spinal cord lesions. In previous biomechanical studies, researchers have vertically dropped human cadavers, head-neck specimens, or surrogate models in inverted postures. Objective To develop a cadaveric neck model to simulate horizontally aligned, head-first impacts with a straightened neck and to use the model to investigate biomechanical responses and failure mechanisms. Design Descriptive laboratory study. Setting Biomechanics research laboratory. Patients or Other Participants Five human cadaveric cervical spine specimens. Intervention(s) The model consisted of the neck specimen mounted horizontally to a torso-equivalent mass on a sled and carrying a surrogate head. Head-first impacts were simulated at 4.1 m/s into a padded, deformable barrier. Main Outcome Measure(s) Time-history responses were determined for head and neck loads, accelerations, and motions. Average occurrence times of the compression force peaks at the impact barrier, occipital condyles, and neck were compared. Results The first local compression force peaks at the impact barrier (3070.0 ± 168.0 N at 18.8 milliseconds), occipital condyles (2868.1 ± 732.4 N at 19.6 milliseconds), and neck (2884.6 ± 910.7 N at 25.0 milliseconds) occurred earlier than all global compression peaks, which reached 7531.6 N in the neck at 46.6 milliseconds (P < .001). Average peak head motions relative to the torso were 6.0 cm in compression, 2.4 cm in posterior shear, and 6.4° in flexion. Neck compression fractures included occipital condyle, atlas, odontoid, and subaxial comminuted burst and facet fractures. Conclusions Neck injuries due to excessive axial compression occurred within 20 milliseconds of impact and were caused by abrupt deceleration of the head and continued forward torso momentum before simultaneous rebound of the head and torso. Improved understanding of neck injury mechanisms during sports-induced impacts will increase clinical awareness and immediate care and ultimately lead to improved protective equipment, reducing the frequency and severity of neck injuries and their associated societal costs. PMID:23068585

  12. Brown Adipose Tissue Quantification in Human Neonates Using Water-Fat Separated MRI

    PubMed Central

    Rasmussen, Jerod M.; Entringer, Sonja; Nguyen, Annie; van Erp, Theo G. M.; Guijarro, Ana; Oveisi, Fariba; Swanson, James M.; Piomelli, Daniele; Wadhwa, Pathik D.

    2013-01-01

    There is a major resurgence of interest in brown adipose tissue (BAT) biology, particularly regarding its determinants and consequences in newborns and infants. Reliable methods for non-invasive BAT measurement in human infants have yet to be demonstrated. The current study first validates methods for quantitative BAT imaging of rodents post mortem followed by BAT excision and re-imaging of excised tissues. Identical methods are then employed in a cohort of in vivo infants to establish the reliability of these measures and provide normative statistics for BAT depot volume and fat fraction. Using multi-echo water-fat MRI, fat- and water-based images of rodents and neonates were acquired and ratios of fat to the combined signal from fat and water (fat signal fraction) were calculated. Neonatal scans (n = 22) were acquired during natural sleep to quantify BAT and WAT deposits for depot volume and fat fraction. Acquisition repeatability was assessed based on multiple scans from the same neonate. Intra- and inter-rater measures of reliability in regional BAT depot volume and fat fraction quantification were determined based on multiple segmentations by two raters. Rodent BAT was characterized as having significantly higher water content than WAT in both in situ as well as ex vivo imaging assessments. Human neonate deposits indicative of bilateral BAT in spinal, supraclavicular and axillary regions were observed. Pairwise, WAT fat fraction was significantly greater than BAT fat fraction throughout the sample (ΔWAT-BAT = 38%, p<10−4). Repeated scans demonstrated a high voxelwise correlation for fat fraction (Rall = 0.99). BAT depot volume and fat fraction measurements showed high intra-rater (ICCBAT,VOL = 0.93, ICCBAT,FF = 0.93) and inter-rater reliability (ICCBAT,VOL = 0.86, ICCBAT,FF = 0.93). This study demonstrates the reliability of using multi-echo water-fat MRI in human neonates for quantification throughout the torso of BAT depot volume and fat fraction measurements. PMID:24205024

  13. A feasibility study of altered spatial distribution of losses induced by eddy currents in body composition analysis

    PubMed Central

    2010-01-01

    Background Tomographic imaging has revealed that the body mass index does not give a reliable state of overall fitness. However, high measurement costs make the tomographic imaging unsuitable for large scale studies or repeated individual use. This paper reports an experimental investigation of a new electromagnetic method and its feasibility for assessing body composition. The method is called body electrical loss analysis (BELA). Methods The BELA method uses a high-Q parallel resonant circuit to produce a time-varying magnetic field. The Q of the resonator changes when the sample is placed in its coil. This is caused by induced eddy currents in the sample. The new idea in the BELA method is the altered spatial distribution of the electrical losses generated by these currents. The distribution of losses is varied using different excitation frequencies. The feasibility of the method was tested using simplified phantoms. Two of these phantoms were rough estimations of human torso. One had fat in the middle of its volume and saline solution in the outer shell volume. The other had reversed conductivity distributions. The phantoms were placed in the resonator and the change in the losses was measured. Five different excitation frequencies from 100 kHz to 200 kHz were used. Results The rate of loss as a function of frequency was observed to be approximately three times larger for a phantom with fat in the middle of its volume than for one with fat in its outer shell volume. Conclusions At higher frequencies the major signal contribution can be shifted toward outer shell volume. This enables probing the conductivity distribution of the subject by weighting outer structural components. The authors expect that the loss changing rate over frequency can be a potential index for body composition analysis. PMID:21047441

  14. Quantifying muscle patterns and spine load during various forms of the push-up.

    PubMed

    Freeman, Stephanie; Karpowicz, Amy; Gray, John; McGill, Stuart

    2006-03-01

    This study was conducted to quantify the normalized amplitudes of the abdominal wall and back extensor musculature during a variety of push-up styles. We also sought to quantify their impact on spinal loading by calculating spinal compression and torque generation in the L4-5 area. Ten university-age participants, nine males and one female, in good to excellent condition, volunteered to participate in this study. All participants were requested to perform a maximum of 12 different push-up exercises, three trials per exercise. Surface electromyographic data (EMG) were collected bilaterally on rectus abdominis, external oblique, internal oblique, latissimus dorsi, and erector spinae muscles, and unilaterally (right side) on pectoralis major, triceps brachii, biceps brachii, and anterior deltoid muscles. Spine kinetics were obtained using an anatomically detailed model of the torso/spine. This study revealed that more dynamic push-ups (i.e., ballistic, with hand movement) required more muscle activation and higher spine load, whereas placing labile balls under the hands only resulted in modest increases in spine load. Right rectus abdominis (RA) activation was significantly higher than left RA activation during the left hand forward push-up and vice versa for the right hand forward push-up (P < 0.001). External oblique (EO) demonstrated the same switch in dominance during staggered hand push-ups (P < 0.01). The one-arm push-up resulted in the highest spine compression. Skilled participants showed greater synchronicity with peak muscle activation (plyometric type of contractions) during ballistic push-ups. These data will help guide exercise selection for individuals with differing training objectives and injury history.

  15. Experiments and analysis concerning the use of external burning to reduce aerospace vehicle transonic drag. Ph.D. Thesis - Maryland Univ., 1991

    NASA Technical Reports Server (NTRS)

    Trefny, Charles J.

    1992-01-01

    The external combustion of hydrogen to reduce transonic drag was investigated. A control volume analysis is developed and indicates that the specific impulse performance of external burning is competitive with other forms of airbreathing propulsion and depends on the fuel-air ratio, freestream Mach number, and the severity of the base drag. A method is presented for sizing fuel injectors for a desired fuel-air ratio in the unconfined stream. A two-dimensional Euler analysis is also presented which indicates that the total axial force generated by external burning depends on the total amount of energy input and is independent of the transverse and streamwise distribution of heat addition. Good agreement between the Euler and control volume analysis is demonstrated. Features of the inviscid external burning flowfield are discussed. Most notably, a strong compression forms at the sonic line within the burning stream which may induce separation of the plume and prevent realization of the full performance potential. An experimental program was conducted in a Mach 1.26 free-jet to demonstrate drag reduction on a simple expansion ramp geometry, and verify hydrogen-air stability limits at external burning conditions. Stable combustion appears feasible to Mach number of between 1.4 and 2 depending on the vehicle flight trajectory. Drag reduction is demonstrated on the expansion ramp at Mach 1.26; however, force levels showed little dependence on fuel pressure or altitude in contrast to control volume analysis predictions. Various facility interference mechanisms and scaling issues were studied and are discussed.

  16. TH-CD-207A-03: A Surface Deformation Driven Respiratory Model for Organ Motion Tracking in Lung Cancer Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, H; Zhen, X; Zhou, L

    Purpose: To propose and validate a novel real-time surface-mesh-based internal organ-external surface motion and deformation tracking method for lung cancer radiotherapy. Methods: Deformation vector fields (DVFs) which characterizes the internal and external motion are obtained by registering the internal organ and tumor contours and external surface meshes to a reference phase in the 4D CT images using a recent developed local topology preserved non-rigid point matching algorithm (TOP). A composite matrix is constructed by combing the estimated internal and external DVFs. Principle component analysis (PCA) is then applied on the composite matrix to extract principal motion characteristics and finally yieldmore » the respiratory motion model parameters which correlates the internal and external motion and deformation. The accuracy of the respiratory motion model is evaluated using a 4D NURBS-based cardiac-torso (NCAT) synthetic phantom and three lung cancer cases. The center of mass (COM) difference is used to measure the tumor motion tracking accuracy, and the Dice’s coefficient (DC), percent error (PE) and Housdourf’s distance (HD) are used to measure the agreement between the predicted and ground truth tumor shape. Results: The mean COM is 0.84±0.49mm and 0.50±0.47mm for the phantom and patient data respectively. The mean DC, PE and HD are 0.93±0.01, 0.13±0.03 and 1.24±0.34 voxels for the phantom, and 0.91±0.04, 0.17±0.07 and 3.93±2.12 voxels for the three lung cancer patients, respectively. Conclusions: We have proposed and validate a real-time surface-mesh-based organ motion and deformation tracking method with an internal-external motion modeling. The preliminary results conducted on a synthetic 4D NCAT phantom and 4D CT images from three lung cancer cases show that the proposed method is reliable and accurate in tracking both the tumor motion trajectory and deformation, which can serve as a potential tool for real-time organ motion and deformation monitoring in lung cancer radiotherapy. This work is supported in part by grant from VARIAN MEDICAL SYSTEMS INC, the National Natural Science Foundation of China (no 81428019 and no 81301940), the Guangdong Natural Science Foundation (2015A030313302)and the 2015 Pearl River S&T Nova Program of Guangzhou (201506010096).« less

  17. 49 CFR 572.177 - Test conditions and instrumentation.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...) except as noted, with channel frequency classes as follows: (1) Pendulum acceleration, CFC 180, (2) Pendulum D-plane rotation (if transducer is used), CFC 60, (3) Torso flexion pulling force (if transducer...

  18. 49 CFR 572.177 - Test conditions and instrumentation.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...) except as noted, with channel frequency classes as follows: (1) Pendulum acceleration, CFC 180, (2) Pendulum D-plane rotation (if transducer is used), CFC 60, (3) Torso flexion pulling force (if transducer...

  19. 49 CFR 572.177 - Test conditions and instrumentation.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...) except as noted, with channel frequency classes as follows: (1) Pendulum acceleration, CFC 180, (2) Pendulum D-plane rotation (if transducer is used), CFC 60, (3) Torso flexion pulling force (if transducer...

  20. 49 CFR 572.131 - General description.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Assembly 880105-300 Lower Torso Assembly 880105-450 Complete Leg Assembly—left 880105-560-1 Complete Leg Assembly—right 880105-560-2 Complete Arm Assembly—left 880105-728-1 Complete Arm Assembly—right 880105-728...

  1. 49 CFR 572.131 - General description.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Assembly 880105-300 Lower Torso Assembly 880105-450 Complete Leg Assembly—left 880105-560-1 Complete Leg Assembly—right 880105-560-2 Complete Arm Assembly—left 880105-728-1 Complete Arm Assembly—right 880105-728...

  2. Scoliosis brace (image)

    MedlinePlus

    ... on the back and ribs to push the spine in a straighter position. The brace usually fits snugly around the torso and can come in many styles. In a child who is still growing, bracing is usually recommended ...

  3. Inside Out. Writings from the Prison Literacy Project. Volumes I-II.

    ERIC Educational Resources Information Center

    Prison Literacy Project, Philadelphia, PA.

    These two volumes contain writings designed for the new reader who is in prison. Written by both inmates and external volunteers, the material in these volumes includes poems, stories, and short essays that deal with subjects of interest to prison inmates. To help the new reader, easier-to-read pieces are presented first. Titles in volume I are as…

  4. Dexterous Humanoid Robotic Wrist

    NASA Technical Reports Server (NTRS)

    Ihrke, Chris A. (Inventor); Bridgwater, Lyndon (Inventor); Reich, David M. (Inventor); Wampler, II, Charles W. (Inventor); Askew, Scott R. (Inventor); Diftler, Myron A. (Inventor); Nguyen, Vienny (Inventor)

    2013-01-01

    A humanoid robot includes a torso, a pair of arms, a neck, a head, a wrist joint assembly, and a control system. The arms and the neck movably extend from the torso. Each of the arms includes a lower arm and a hand that is rotatable relative to the lower arm. The wrist joint assembly is operatively defined between the lower arm and the hand. The wrist joint assembly includes a yaw axis and a pitch axis. The pitch axis is disposed in a spaced relationship to the yaw axis such that the axes are generally perpendicular. The pitch axis extends between the yaw axis and the lower arm. The hand is rotatable relative to the lower arm about each of the yaw axis and the pitch axis. The control system is configured for determining a yaw angle and a pitch angle of the wrist joint assembly.

  5. Traces across the body: influence of music-dance synchrony on the observation of dance.

    PubMed

    Woolhouse, Matthew Harold; Lai, Rosemary

    2014-01-01

    In previous studies investigating entrainment and person perception, synchronized movements were found to enhance memory for incidental person attributes. Although this effect is robust, including in dance, the process by which it is actuated are less well understood. In this study, two hypotheses are investigated: that enhanced memory for person attributes is the result of (1) increased gaze time between in-tempo dancers; and/or (2) greater attentional focus between in-tempo dancers. To explore these possible mechanisms in the context of observing dance, an eye-tracking study was conducted in which subjects watched videos of pairs of laterally positioned dancers; only one of the dancers was synchronized with the music, the other being asynchronous. The results were consistent with the first hypothesis-music-dance synchrony gives rise to increased visual inspection times. In addition, there was a preference for upper-body fixations over lower-body fixations across both synchronous and asynchronous conditions. A subsequent, single-dancer eye-tracking study investigated fixations across different body regions, including head, torso, legs and feet. Significantly greater dwell times were recorded for head than torso and legs; feet attracted significantly less dwell time than any other body region. Lastly, the study sought to identify dance gestures responsible for torso- and head-directed fixations. Specifically we asked whether there are features in dance that are specially designed to direct an observer's gaze towards the face-the main "communicative portal" with respect to the transmission of intent, affect and empathy.

  6. Traces across the body: influence of music-dance synchrony on the observation of dance

    PubMed Central

    Woolhouse, Matthew Harold; Lai, Rosemary

    2014-01-01

    In previous studies investigating entrainment and person perception, synchronized movements were found to enhance memory for incidental person attributes. Although this effect is robust, including in dance, the process by which it is actuated are less well understood. In this study, two hypotheses are investigated: that enhanced memory for person attributes is the result of (1) increased gaze time between in-tempo dancers; and/or (2) greater attentional focus between in-tempo dancers. To explore these possible mechanisms in the context of observing dance, an eye-tracking study was conducted in which subjects watched videos of pairs of laterally positioned dancers; only one of the dancers was synchronized with the music, the other being asynchronous. The results were consistent with the first hypothesis—music-dance synchrony gives rise to increased visual inspection times. In addition, there was a preference for upper-body fixations over lower-body fixations across both synchronous and asynchronous conditions. A subsequent, single-dancer eye-tracking study investigated fixations across different body regions, including head, torso, legs and feet. Significantly greater dwell times were recorded for head than torso and legs; feet attracted significantly less dwell time than any other body region. Lastly, the study sought to identify dance gestures responsible for torso- and head-directed fixations. Specifically we asked whether there are features in dance that are specially designed to direct an observer’s gaze towards the face—the main “communicative portal” with respect to the transmission of intent, affect and empathy. PMID:25520641

  7. Injury Source and Correlation Analysis of Riders in Car-Electric Bicycle Accidents.

    PubMed

    Zou, Tiefang; Yi, Liang; Cai, Ming; Hu, Lin; Li, Yuelin

    2018-01-01

    The knowledge about the injury source and correlation of riders in car-electric bicycle accident will be helpful in the cross validation of traces and vehicle safety design. In order to know more information about such kind of knowledge, 57 true car-electric bicycle accidents were reconstructed by PC-Crash and then data on injury information of riders were collected directly from the reconstructed cases. These collected data were validated by some existing research results firstly, and then 4 abnormal cases were deleted according to the statistical method. Finally, conclusions can be obtained according to the data obtained from the remaining 53 cases. Direct injuries of the head and right leg are from the road pavement upon low speed; the source laws of indirect head injuries are not obvious. Upon intermediate and high speed, the injuries of the above parts are from automobiles. Injuries of the left leg, femur, and right knee are from automobiles; left knee injuries are from automobiles, the road pavement and automobiles, respectively, upon low, intermediate, and high speed. The source laws of indirect torso injuries are not obvious upon intermediate and low speed, which are from automobiles upon high speed, while direct torso injuries are from the road pavement. And there is no high correlation between all parts of the injury of riders. The largest correlation coefficient was the head-left femur and left femur-right femur, which was 0.647, followed by the head-right femur (0.638) and head-torso which was 0.617.

  8. A Monte Carlo Simulation of the in vivo measurement of lung activity in the Lawrence Livermore National Laboratory torso phantom.

    PubMed

    Acha, Robert; Brey, Richard; Capello, Kevin

    2013-02-01

    A torso phantom was developed by the Lawrence Livermore National Laboratory (LLNL) that serves as a standard for intercomparison and intercalibration of detector systems used to measure low-energy photons from radionuclides, such as americium deposited in the lungs. DICOM images of the second-generation Human Monitoring Laboratory-Lawrence Livermore National Laboratory (HML-LLNL) torso phantom were segmented and converted into three-dimensional (3D) voxel phantoms to simulate the response of high purity germanium (HPGe) detector systems, as found in the HML new lung counter using a Monte Carlo technique. The photon energies of interest in this study were 17.5, 26.4, 45.4, 59.5, 122, 244, and 344 keV. The detection efficiencies at these photon energies were predicted for different chest wall thicknesses (1.49 to 6.35 cm) and compared to measured values obtained with lungs containing (241)Am (34.8 kBq) and (152)Eu (10.4 kBq). It was observed that no statistically significant differences exist at the 95% confidence level between the mean values of simulated and measured detection efficiencies. Comparisons between the simulated and measured detection efficiencies reveal a variation of 20% at 17.5 keV and 1% at 59.5 keV. It was found that small changes in the formulation of the tissue substitute material caused no significant change in the outcome of Monte Carlo simulations.

  9. Torso undergarments: their merit for clothed and armored individuals in hot-dry conditions.

    PubMed

    Van den Heuvel, Anne M J; Kerry, Pete; Van der Velde, Jeroen H P M; Patterson, Mark J; Taylor, Nigel A S

    2010-12-01

    The aim of this study was to evaluate how the textile composition of torso undergarment fabrics may impact upon thermal strain, moisture transfer, and the thermal and clothing comfort of fully clothed, armored individuals working in a hot-dry environment (41.2 degrees C and 29.8% relative humidity). Five undergarment configurations were assessed using eight men who walked for 120 min (4 km x h(-1)), then alternated running (2 min at 10 km x h(-1)) and walking (2 min at 4 km x h(-1)) for 20 min. Trials differed only in the torso undergarments worn: no t-shirt (Ensemble A); 100% cotton t-shirt (Ensemble B); 100% woolen t-shirt (Ensemble C); synthetic t-shirt (Ensemble D: nylon, polyethylene, elastane); hybrid shirt (Ensemble E). Thermal and cardiovascular strain progressively increased throughout each trial, with the average terminal core temperature being 38.5 degrees C and heart rate peaking at 170 bpm across all trials. However, no significant between-trial separations were evident for core or mean skin temperatures, or for heart rate, sweat production, evaporation, the within-ensemble water vapor pressures, or for thermal or clothing discomfort. Thus, under these conditions, neither the t-shirt textile compositions, nor the presence or absence of an undergarment, offered any significant thermal, central cardiac, or comfort advantages. Furthermore, there was no evidence that any of these fabrics created a significantly drier microclimate next to the skin.

  10. A Prospective Analysis on Functional Outcomes Following Extended Latissimus Dorsi Flap Breast Reconstruction.

    PubMed

    Eyjolfsdottir, H; Haraldsdottir, B; Ragnarsdottir, M; Asgeirsson, K S

    2017-06-01

    To prospectively assess the functional effect of using the extended latissimus dorsi flap in immediate breast reconstructions. A total of 15 consecutive patients undergoing breast reconstruction with extended latissimus dorsi flap participated. Shoulder range of motion, muscle strength, lateral flexion of the torso, and position of scapula were measured pre-operatively and 1, 6, and 12 months post-operatively, in addition to donor-site post-operative complications. At 12 months post-operatively, patients had achieved full range of shoulder movement, when compared to pre-operative values. Lateral flexion of the torso was, however, significantly reduced bilaterally at 1 and 6 months post-operatively (p = 0.001, p = 0.01) and to the not operated side at 12 months (p = 0.01). Muscle strength in flexion-extension-internal rotation was significantly (p = 0.01) reduced on the operated side 12 months post-operatively. All but one patient had numbness around the donor-site scar 12 months post-operatively, 33% had slight adhesions but all were pain free. Although invariably, patients having extended latissimus dorsi flap may expect to achieve full range of shoulder movement, they should be informed of possible functional consequences and the time and effort it takes to recover. Further research is needed to investigate the potential long-term functional implications that extended latissimus dorsi flap may have as a result of changes in the lateral flexion of the torso and scapula position.

  11. MATSIM -The Development and Validation of a Numerical Voxel Model based on the MATROSHKA Phantom

    NASA Astrophysics Data System (ADS)

    Beck, Peter; Rollet, Sofia; Berger, Thomas; Bergmann, Robert; Hajek, Michael; Latocha, Marcin; Vana, Norbert; Zechner, Andrea; Reitz, Guenther

    The AIT Austrian Institute of Technology coordinates the project MATSIM (MATROSHKA Simulation) in collaboration with the Vienna University of Technology and the German Aerospace Center. The aim of the project is to develop a voxel-based model of the MATROSHKA anthro-pomorphic torso used at the International Space Station (ISS) as foundation to perform Monte Carlo high-energy particle transport simulations for different irradiation conditions. Funded by the Austrian Space Applications Programme (ASAP), MATSIM is a co-investigation with the European Space Agency (ESA) ELIPS project MATROSHKA, an international collaboration of more than 18 research institutes and space agencies from all over the world, under the science and project lead of the German Aerospace Center. The MATROSHKA facility is designed to determine the radiation exposure of an astronaut onboard ISS and especially during an ex-travehicular activity. The numerical model developed in the frame of MATSIM is validated by reference measurements. In this report we give on overview of the model development and compare photon and neutron irradiations of the detector-equipped phantom torso with Monte Carlo simulations using FLUKA. Exposure to Co-60 photons was realized in the standard ir-radiation laboratory at Seibersdorf, while investigations with neutrons were performed at the thermal column of the Vienna TRIGA Mark-II reactor. The phantom was loaded with passive thermoluminescence dosimeters. In addition, first results of the calculated dose distribution within the torso are presented for a simulated exposure in low-Earth orbit.

  12. Investigation of a relationship between external force to shoulder and chest injury of WorldSID and THUMS in 32 km/h oblique pole side impact.

    PubMed

    Tanaka, Shinobu; Hayashi, Shigeki; Fukushima, Satoshi; Yasuki, Tsuyoshi

    2013-01-01

    This article describes the chest injury risk reduction effect of shoulder restraints using finite element (FE) models of the worldwide harmonized side impact dummy (WorldSID) and Total Human Model for Safety (THUMS) in an FE model 32 km/h oblique pole side impact. This research used an FE model of a mid-sized vehicle equipped with various combinations of curtain shield air bags, torso air bags, and shoulder restraint air bags. As occupant models, AM50 WorldSID and THUMS AM50 Version 4 were used for comparison. The research investigated the effect of shoulder restraint air bag on chest injury by comparing cases with and without a shoulder side air bag. The maximum external force to the chest was reduced by shoulder restraint air bag in both WorldSID and THUMS, reducing chest injury risk as measured by the amount of rib deflection, number of the rib fractures, and rib deflection ratio. However, it was also determined that the external force to shoulder should be limited to the chest injury threshold because the external shoulder force transmits to the chest via the arm in the case of WorldSID and via the scapula in the case of THUMS. Because these results show the shoulder restraint air bag effect on chest injury risk, the vent hole size of the shoulder restraint air bag was changed for varying reaction forces to investigate the relationship between the external force to the shoulder and the risk of chest injury. In the case of THUMS, an external shoulder force of 1.8 kN and more force from the shoulder restraint air bag was necessary to help prevent rib fracture. Increasing external force applied to shoulder up to 6.2 kN (the maximum force used in this study) did not induce any rib or clavicle fractures in the THUMS. When the shoulder restraint air bag generated external force to the shoulder from 1.8 to 6.2 kN in THUMS, which were applied to the WorldSID, the shoulder deflection ranged from 35 to 68 mm, and the shoulder force ranged from 1.8 to 2.3 kN. In the test configuration used, a shoulder restraint using the air bag helps reduce chest injury risk by lowering the maximum magnitude of external force to the shoulder and chest. To help reduce rib fracture risk in the THUMS, the shoulder restraint air bag was expected to generate a force of 3.7 kN with a minimum rib deflection ratio. This corresponds to a shoulder rib deflection of 60 mm and a shoulder load of 2.2 kN in WorldSID. Supplemental materials are available for this article. Go to the publisher's online edition of Traffic Injury Prevention to view the supplemental file.

  13. A Comparative Analysis of Two Full-Scale MD-500 Helicopter Crash Tests

    NASA Technical Reports Server (NTRS)

    Littell, Justin D.

    2011-01-01

    Two full scale crash tests were conducted on a small MD-500 helicopter at NASA Langley Research Center fs Landing and Impact Research Facility. One of the objectives of this test series was to compare airframe impact response and occupant injury data between a test which outfitted the airframe with an external composite passive energy absorbing honeycomb and a test which had no energy absorbing features. In both tests, the nominal impact velocity conditions were 7.92 m/sec (26 ft/sec) vertical and 12.2 m/sec (40 ft/sec) horizontal, and the test article weighed approximately 1315 kg (2900 lbs). Airframe instrumentation included accelerometers and strain gages. Four Anthropomorphic Test Devices were also onboard; three of which were standard Hybrid II and III, while the fourth was a specialized torso. The test which contained the energy absorbing honeycomb showed vertical impact acceleration loads of approximately 15 g, low risk for occupant injury probability, and minimal airframe damage. These results were contrasted with the test conducted without the energy absorbing honeycomb. The test results showed airframe accelerations of approximately 40 g in the vertical direction, high risk for injury probability in the occupants, and substantial airframe damage.

  14. The relationship between general measures of fitness, passive range of motion and whole-body movement quality.

    PubMed

    Frost, David; Andersen, Jordan; Lam, Thomas; Finlay, Tim; Darby, Kevin; McGill, Stuart

    2013-01-01

    The goal of this study was to establish relationships between fitness (torso endurance, grip strength and pull-ups), hip range of motion (ROM) (extension, flexion, internal and external rotation) and movement quality in an occupational group with physical work demands. Fifty-three men from the emergency task force of a major city police force were investigated. The movement screen comprised standing and seated posture, gait, segmental spine motion and 14 tasks designed to challenge whole-body coordination. Relationships were established between each whole-body movement task, the measures of strength, endurance and ROM. In general, fitness and ROM were not strongly related to the movement quality of any task. This has implications for worker training, in that strategies developed to improve ROM or strength about a joint may not enhance movement quality. Worker-centered injury prevention can be described as fitting workers to tasks by improving fitness and modifying movement patterns; however, the current results show weak correlations between strength, endurance and ROM, and the way individuals move. Therefore, the development of occupation-specific injury prevention strategies may require both fitness and movement-oriented objectives.

  15. Orbital flight test shuttle external tank aerothermal flight evaluation, volume 1

    NASA Technical Reports Server (NTRS)

    Praharaj, Sarat C.; Engel, Carl D.; Warmbrod, John D.

    1986-01-01

    This 3-volume report discusses the evaluation of aerothermal flight measurements made on the orbital flight test Space Shuttle External Tanks (ETs). Six ETs were instrumented to measure various quantities during flight; including heat transfer, pressure, and structural temperature. The flight data was reduced and analyzed against math models established from an extensive wind tunnel data base and empirical heat-transfer relationships. This analysis has supported the validity of the current aeroheating methodology and existing data base; and, has also identified some problem areas which require methodology modifications. This is Volume 1, an Executive Summary. Volume 2 contains Appendices A (Aerothermal Comparisons) and B (Flight Derived h sub 1/h sub u vs. M sub inf. Plots), and Volume 3 contains Appendix C (Comparison of Interference Factors among OFT Flight, Prediction and 1H-97A Data), Appendix D (Freestream Stanton Number and Reynolds Number Correlation for Flight and Tunnel Data), and Appendix E (Flight-Derived h sub i/h sub u Tables).

  16. Orbital flight test shuttle external tank aerothermal flight evaluation, volume 3

    NASA Technical Reports Server (NTRS)

    Praharaj, Sarat C.; Engel, Carl D.; Warmbrod, John D.

    1986-01-01

    This 3-volume report discusses the evaluation of aerothermal flight measurements made on the orbital flight test Space Shuttle External Tanks (ETs). Six ETs were instrumented to measure various quantities during flight; including heat transfer, pressure, and structural temperature. The flight data was reduced and analyzed against math models established from an extensive wind tunnel data base and empirical heat-transfer relationships. This analysis has supported the validity of the current aeroheating methodology and existing data base; and, has also identified some problem areas which require methodology modifications. Volume 1 is the Executive Summary. Volume 2 contains Appendix A (Aerothermal Comparisons), and Appendix B (Flight-Derived h sub 1/h sub u vs. M sub inf. Plots). This is Volume 3, containing Appendix C (Comparison of Interference Factors between OFT Flight, Prediction and 1H-97A Data), Appendix D (Freestream Stanton Number and Reynolds Number Correlation for Flight and Tunnel Data), and Appendix E (Flight-Derived h sub i/h sub u Tables).

  17. Orbital flight test shuttle external tank aerothermal flight evaluation, volume 2

    NASA Technical Reports Server (NTRS)

    Praharaj, Sarat C.; Engel, Carl D.; Warmbrod, John D.

    1986-01-01

    This 3-volume report discusses the evaluation of aerothermal flight measurements made on the orbital flight test Space Shuttle External Tanks (ETs). Six ETs were instrumented to measure various quantities during flight; including heat transfer, pressure, and structural temperature. The flight data was reduced and analyzed against math models established from an extensive wind tunnel data base and empirical heat-transfer relationships. This analysis has supported the validity of the current aeroheating methodology and existing data base; and, has also identified some problem areas which require methodology modifications. Volume 1 is the Executive Summary. This is volume 2, containing Appendix A (Aerothermal Comparisons), and Appendix B (Flight-Derived h sub i/h sub u vs. M sub inf. Plots). Volume 3 contains Appendix C (Comparison of Interference Factors between OFT Flight, Prediction and 1H-97A Data), Appendix D (Freestream Stanton Number and Reynolds Number Correlation for Flight and Tunnel Data), and Appendix E (Flight-Derived h sub i/h sub u Tables).

  18. 49 CFR 572.194 - Shoulder.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., while the midsagittal plane of the dummy is in vertical orientation. (4) Push the dummy at the knees and... back until the back of the upper torso is in contact with the seat back. (5) While maintaining the...

  19. A Five-Dimensional Mathematical Model for Regional and Global Changes in Cardiac Uptake and Motion

    NASA Astrophysics Data System (ADS)

    Pretorius, P. H.; King, M. A.; Gifford, H. C.

    2004-10-01

    The objective of this work was to simultaneously introduce known regional changes in contraction pattern and perfusion to the existing gated Mathematical Cardiac Torso (MCAT) phantom heart model. We derived a simple integral to calculate the fraction of the ellipsoidal volume that makes up the left ventricle (LV), taking into account the stationary apex and the moving base. After calculating the LV myocardium volume of the existing beating heart model, we employed the property of conservation of mass to manipulate the LV ejection fraction to values ranging between 13.5% and 68.9%. Multiple dynamic heart models that differ in degree of LV wall thickening, base-to-apex motion, and ejection fraction, are thus available for use with the existing MCAT methodology. To introduce more complex regional LV contraction and perfusion patterns, we used composites of dynamic heart models to create a central region with little or no motion or perfusion, surrounded by a region in which the motion and perfusion gradually reverts to normal. To illustrate this methodology, the following gated cardiac acquisitions for different clinical situations were simulated analytically: 1) reduced regional motion and perfusion; 2) same perfusion as in (1) without motion intervention; and 3) washout from the normal and diseased myocardial regions. Both motion and perfusion can change dynamically during a single rotation or multiple rotations of a simulated single-photon emission computed tomography acquisition system.

  20. A programmable point-of-care device for external CSF drainage and monitoring.

    PubMed

    Simkins, Jeffrey R; Subbian, Vignesh; Beyette, Fred R

    2014-01-01

    This paper presents a prototype of a programmable cerebrospinal fluid (CSF) external drainage system that can accurately measure the dispensed fluid volume. It is based on using a miniature spectrophotometer to collect color data to inform drain rate and pressure monitoring. The prototype was machined with 1 μm dimensional accuracy. The current device can reliably monitor the total accumulated fluid volume, the drain rate, the programmed pressure, and the pressure read from the sensor. Device requirements, fabrication processes, and preliminary results with an experimental set-up are also presented.

  1. Traffic data collection for transportation planning in the Dallas-Fort Worth area. Interim research report, January 1994-July 1995

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Perkinson, D.G.; Dresser, G.B.

    1995-07-01

    The Texas Transportation Institute (TTI), under a contract with the Dallas District of the Texas Department of Transportation (TxDOT), provided traffic data for the North Central Texas Council of Governments (NCTOG) for their transportation planning in the Dallas-Fort Worth area. This effort included volume counts, vehicle classification counts, and speed data for 23 urban corridors in the area. In addition, external station volume counts were collected for 32 external stations, and journey travel time data were collected for nine activity centers.

  2. Methods and computer readable medium for improved radiotherapy dosimetry planning

    DOEpatents

    Wessol, Daniel E.; Frandsen, Michael W.; Wheeler, Floyd J.; Nigg, David W.

    2005-11-15

    Methods and computer readable media are disclosed for ultimately developing a dosimetry plan for a treatment volume irradiated during radiation therapy with a radiation source concentrated internally within a patient or incident from an external beam. The dosimetry plan is available in near "real-time" because of the novel geometric model construction of the treatment volume which in turn allows for rapid calculations to be performed for simulated movements of particles along particle tracks therethrough. The particles are exemplary representations of alpha, beta or gamma emissions emanating from an internal radiation source during various radiotherapies, such as brachytherapy or targeted radionuclide therapy, or they are exemplary representations of high-energy photons, electrons, protons or other ionizing particles incident on the treatment volume from an external source. In a preferred embodiment, a medical image of a treatment volume irradiated during radiotherapy having a plurality of pixels of information is obtained.

  3. Spacelab Science Results Study. Volume 1; External Observations

    NASA Technical Reports Server (NTRS)

    Naumann, Robert J. (Compiler)

    1999-01-01

    Some of the 36 Spacelab missions were more or less dedicated to specific scientific disciplines, while other carried a eclectic mixture of experiments ranging from astrophysics to life sciences. However, the experiments can be logically classified into two general categories; those that make use of the Shuttle as an observing platform for external phenomena (including those which use the Shuttle in an interactive mode) and those which use the Shuttle as a microgravity laboratory. This first volume of this Spacelab Science Results study will be devoted to experiments of the first category. The disciplines included are Astrophysics, Solar Physics, Space Plasma Physics, Atmospheric Sciences, and Earth Sciences. Because of the large number of microgravity investigations, Volume 2 will be devoted to Microgravity Sciences, which includes Fluid Physics, Combustion Science, Materials Science, and Biotechnology, and Volume 3 will be devoted to Space Life Sciences, which studies the response and adaptability of living organisms to the microgravity environment.

  4. Preoperative single fraction partial breast radiotherapy for early-stage breast cancer.

    PubMed

    Palta, Manisha; Yoo, Sua; Adamson, Justus D; Prosnitz, Leonard R; Horton, Janet K

    2012-01-01

    Several recent series evaluating external beam accelerated partial breast irradiation (PBI) have reported adverse cosmetic outcomes, possibly related to large volumes of normal tissue receiving near-prescription doses. We hypothesized that delivery of external beam PBI in a single fraction to the preoperative tumor volume would be feasible and result in a decreased dose to the uninvolved breast compared with institutional postoperative PBI historical controls. A total of 17 patients with unifocal Stage T1 breast cancer were identified. Contrast-enhanced subtraction magnetic resonance images were loaded into an Eclipse treatment planning system and used to define the target volumes. A "virtual plan" was created using four photon beams in a noncoplanar beam arrangement and optimized to deliver 15 Gy to the planning target volume. The median breast volume was 1,713 cm(3) (range: 1,014-2,140), and the median clinical target volume was 44 cm(3) (range: 26-73). In all cases, 100% of the prescription dose covered 95% of the clinical target volume. The median conformity index was 0.86 (range: 0.70-1.12). The median percentage of the ipsilateral breast volume receiving 100% and 50% of the prescribed dose was 3.8% (range: 2.2-6.9) and 13.3% (range: 7.5-20.8) compared with 18% (range: 3-42) and 53% (range: 24-65) in the institutional historical controls treated with postoperative external beam PBI (p = .002). The median maximum skin dose was 9 Gy. The median dose to 1 and 10 cm(3) of skin was 6.7 and 4.9 Gy. The doses to the heart and ipsilateral lung were negligible. Preoperative PBI resulted in a substantial reduction in ipsilateral breast tissue dose compared with postoperative PBI. The skin dose appeared reasonable, given the small volumes. A prospective Phase I trial evaluating this technique is ongoing. Copyright © 2012 Elsevier Inc. All rights reserved.

  5. The Electrocardiogram as an Example of Electrostatics

    ERIC Educational Resources Information Center

    Hobbie, Russell K.

    1973-01-01

    Develops a simplified electrostatic model of the heart with conduction within the torso neglected to relate electrocardiogram patterns to the charge distribution within the myocardium. Suggests its application to explanation of Coulomb's law in general physics. (CC)

  6. Toward anthropomimetic robotics: development, simulation, and control of a musculoskeletal torso.

    PubMed

    Wittmeier, Steffen; Alessandro, Cristiano; Bascarevic, Nenad; Dalamagkidis, Konstantinos; Devereux, David; Diamond, Alan; Jäntsch, Michael; Jovanovic, Kosta; Knight, Rob; Marques, Hugo Gravato; Milosavljevic, Predrag; Mitra, Bhargav; Svetozarevic, Bratislav; Potkonjak, Veljko; Pfeifer, Rolf; Knoll, Alois; Holland, Owen

    2013-01-01

    Anthropomimetic robotics differs from conventional approaches by capitalizing on the replication of the inner structures of the human body, such as muscles, tendons, bones, and joints. Here we present our results of more than three years of research in constructing, simulating, and, most importantly, controlling anthropomimetic robots. We manufactured four physical torsos, each more complex than its predecessor, and developed the tools required to simulate their behavior. Furthermore, six different control approaches, inspired by classical control theory, machine learning, and neuroscience, were developed and evaluated via these simulations or in small-scale setups. While the obtained results are encouraging, we are aware that we have barely exploited the potential of the anthropomimetic design so far. But, with the tools developed, we are confident that this novel approach will contribute to our understanding of morphological computation and human motor control in the future.

  7. Multiple superficial basal cell carcinomata--topical imiquimod versus curette and cryotherapy.

    PubMed

    Dixon, Anthony J

    2005-01-01

    Superficial basal cell carcinoma can be successfully managed by means other than surgical excision. Nonexcisional approaches include topical imiquimod, and curette and cryotherapy (C&C). This article discusses the management of an insulin dependent diabetic man aged 52 years presenting with 17 torso basal cell carcinomas (BCCs); mostly superficial BCCs (SBCCs). Half were treated with topical imiquimod. The remaining lesions were treated with curette and cryotherapy. All lesions resolved with proven histologic clearance. The patient considered C&C caused him less discomfort and disruption. He developed a late secondary infection in some sites treated with imiquimod. At 12 months there was no evidence of recurrence though new nodular BCCs and SBCCs had developed elsewhere on his upper torso. He has elected to have future SBCCs managed with C&C. While excisional surgery remains the benchmark management for nonmelanoma skin cancer, topical imiquimod and C&C are important options for treating SBCCs.

  8. Alternative input medium development for wheelchair user with severe spinal cord injury

    NASA Astrophysics Data System (ADS)

    Ihsan, Izzat Aqmar; Tomari, Razali; Zakaria, Wan Nurshazwani Wan; Othman, Nurmiza

    2017-09-01

    Quadriplegia or tetraplegia patients have restricted four limbs as well as torso movement caused by severe spinal cord injury. Undoubtedly, these patients face difficulties when operating their powered electric wheelchair since they are unable to control the wheelchair by means of a standard joystick. Due to total loss of both sensory and motor function of the four limbs and torso, an alternative input medium for the wheelchair will be developed to assist the user in operating the wheelchair. In this framework, the direction of the wheelchair movement is determined by the user's conscious intent through a brain control interface (BCI) based on Electroencephalogram (EEG) signal. A laser range finder (LFR) is used to perceive environment information for determining a safety distance of the wheelchair's surrounding. Local path planning algorithm will be developed to provide navigation planner along with user's input to prevent collision during control operation.

  9. Dedicated mobile high resolution prostate PET imager with an insertable transrectal probe

    DOEpatents

    Majewski, Stanislaw; Proffitt, James

    2010-12-28

    A dedicated mobile PET imaging system to image the prostate and surrounding organs. The imaging system includes an outside high resolution PET imager placed close to the patient's torso and an insertable and compact transrectal probe that is placed in close proximity to the prostate and operates in conjunction with the outside imager. The two detector systems are spatially co-registered to each other. The outside imager is mounted on an open rotating gantry to provide torso-wide 3D images of the prostate and surrounding tissue and organs. The insertable probe provides closer imaging, high sensitivity, and very high resolution predominately 2D view of the prostate and immediate surroundings. The probe is operated in conjunction with the outside imager and a fast data acquisition system to provide very high resolution reconstruction of the prostate and surrounding tissue and organs.

  10. Experimental investigation of biodynamic human body models subjected to whole-body vibration during a vehicle ride.

    PubMed

    Taskin, Yener; Hacioglu, Yuksel; Ortes, Faruk; Karabulut, Derya; Arslan, Yunus Ziya

    2018-02-06

    In this study, responses of biodynamic human body models to whole-body vibration during a vehicle ride were investigated. Accelerations were acquired from three different body parts, such as the head, upper torso and lower torso, of 10 seated passengers during a car ride while two different road conditions were considered. The same multipurpose vehicle was used during all experiments. Additionally, by two widely used biodynamic models in the literature, a set of simulations were run to obtain theoretical accelerations of the models and were compared with those obtained experimentally. To sustain a quantified comparison between experimental and theoretical approaches, the root mean square acceleration and acceleration spectral density were calculated. Time and frequency responses of the models demonstrated that neither of the models showed the best prediction performance of the human body behaviour in all cases, indicating that further models are required for better prediction of the human body responses.

  11. Injury Source and Correlation Analysis of Riders in Car-Electric Bicycle Accidents

    PubMed Central

    Yi, Liang; Hu, Lin; Li, Yuelin

    2018-01-01

    The knowledge about the injury source and correlation of riders in car-electric bicycle accident will be helpful in the cross validation of traces and vehicle safety design. In order to know more information about such kind of knowledge, 57 true car-electric bicycle accidents were reconstructed by PC-Crash and then data on injury information of riders were collected directly from the reconstructed cases. These collected data were validated by some existing research results firstly, and then 4 abnormal cases were deleted according to the statistical method. Finally, conclusions can be obtained according to the data obtained from the remaining 53 cases. Direct injuries of the head and right leg are from the road pavement upon low speed; the source laws of indirect head injuries are not obvious. Upon intermediate and high speed, the injuries of the above parts are from automobiles. Injuries of the left leg, femur, and right knee are from automobiles; left knee injuries are from automobiles, the road pavement and automobiles, respectively, upon low, intermediate, and high speed. The source laws of indirect torso injuries are not obvious upon intermediate and low speed, which are from automobiles upon high speed, while direct torso injuries are from the road pavement. And there is no high correlation between all parts of the injury of riders. The largest correlation coefficient was the head-left femur and left femur-right femur, which was 0.647, followed by the head-right femur (0.638) and head-torso which was 0.617. PMID:29849757

  12. SU-F-207-03: Dosimetric Effect of the Position of Arms in Torso CT Scan with Tube Current Modulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, H; Rensselaer Polytechnic Institute, Troy, NY; Gao, Y

    Purpose: To evaluate the patient organ dose differences between the arms-raised and arms-lowered postures in Torso multidetector computed tomography (MDCT) scan protocols with tube current modulation (TCM). Methods: Patient CT organ doses were simulated using the Monte Carlo method with human phantoms and a validated CT scanner model. A set of adult human phantoms with arms raised and arms lowered postures were developed using advanced BREP-based mesh surface geometries. Organ doses from routine Torso scan protocols such as chest, abdomen-pelvis, and CAP scans were simulated. The organ doses differences caused by two different posutres were investigated when tube current modulationmore » (TCM) were applied during the CT scan. Results: With TCM applied, organ doses of all the listed organs of arms-lowered posture phantom are larger than those of arms raised phantom. The dose difference for most of the organs or tissues are larger than 50%, and the skin doses difference for abdomen-pelvis scan even reaches 112.03%. This is due to the fact that the tube current for patient with arms-lowered is much higher than for the arms raised posture. Conclusion: Considering CT scan with TCM, which is commonly applied clinically, patients who could not raise their arms will receive higher radiation dose than the arms raised patient, with dose differences for some tissues such as the skin being larger than 100%. This is due to the additional tube current necessary to penetrate the arms while maintaining consistent image quality. National Nature Science Foundation of China(No.11475047)« less

  13. Coordinated three-dimensional motion of the head and torso by dynamic neural networks.

    PubMed

    Kim, J; Hemami, H

    1998-01-01

    The problem of trajectory tracking control of a three dimensional (3D) model of the human upper torso and head is considered. The torso and the head are modeled as two rigid bodies connected at one point, and the Newton-Euler method is used to derive the nonlinear differential equations that govern the motion of the system. The two-link system is driven by six pairs of muscle like actuators that possess physiologically inspired alpha like and gamma like inputs, and spindle like and Golgi tendon organ like outputs. These outputs are utilized as reflex feedback for stability and stiffness control, in a long loop feedback for the purpose of estimating the state of the system (somesthesis), and as part of the input to the controller. Ideal delays of different duration are included in the feedforward and feedback paths of the system to emulate such delays encountered in physiological systems. Dynamical neural networks are trained to learn effective control of the desired maneuvers of the system. The feasibility of the controller is demonstrated by computer simulation of the successful execution of the desired maneuvers. This work demonstrates the capabilities of neural circuits in controlling highly nonlinear systems with multidelays in their feedforward and feedback paths. The ultimate long range goal of this research is toward understanding the working of the central nervous system in controlling movement. It is an interdisciplinary effort relying on mechanics, biomechanics, neuroscience, system theory, physiology and anatomy, and its short range relevance to rehabilitation must be noted.

  14. Investigation of multichannel phased array performance for fetal MR imaging on 1.5T clinical MR system

    PubMed Central

    Li, Ye; Pang, Yong; Vigneron, Daniel; Glenn, Orit; Xu, Duan; Zhang, Xiaoliang

    2011-01-01

    Fetal MRI on 1.5T clinical scanner has been increasingly becoming a powerful imaging tool for studying fetal brain abnormalities in vivo. Due to limited availability of dedicated fetal phased arrays, commercial torso or cardiac phased arrays are routinely used for fetal scans, which are unable to provide optimized SNR and parallel imaging performance with a small number coil elements, and insufficient coverage and filling factor. This poses a demand for the investigation and development of dedicated and efficient radiofrequency (RF) hardware to improve fetal imaging. In this work, an investigational approach to simulate the performance of multichannel flexible phased arrays is proposed to find a better solution to fetal MR imaging. A 32 channel fetal array is presented to increase coil sensitivity, coverage and parallel imaging performance. The electromagnetic field distribution of each element of the fetal array is numerically simulated by using finite-difference time-domain (FDTD) method. The array performance, including B1 coverage, parallel reconstructed images and artifact power, is then theoretically calculated and compared with the torso array. Study results show that the proposed array is capable of increasing B1 field strength as well as sensitivity homogeneity in the entire area of uterus. This would ensure high quality imaging regardless of the location of the fetus in the uterus. In addition, the paralleling imaging performance of the proposed fetal array is validated by using artifact power comparison with torso array. These results demonstrate the feasibility of the 32 channel flexible array for fetal MR imaging at 1.5T. PMID:22408747

  15. Automated segmentation and recognition of the bone structure in non-contrast torso CT images using implicit anatomical knowledge

    NASA Astrophysics Data System (ADS)

    Zhou, X.; Hayashi, T.; Han, M.; Chen, H.; Hara, T.; Fujita, H.; Yokoyama, R.; Kanematsu, M.; Hoshi, H.

    2009-02-01

    X-ray CT images have been widely used in clinical diagnosis in recent years. A modern CT scanner can generate about 1000 CT slices to show the details of all the human organs within 30 seconds. However, CT image interpretations (viewing 500-1000 slices of CT images manually in front of a screen or films for each patient) require a lot of time and energy. Therefore, computer-aided diagnosis (CAD) systems that can support CT image interpretations are strongly anticipated. Automated recognition of the anatomical structures in CT images is a basic pre-processing of the CAD system. The bone structure is a part of anatomical structures and very useful to act as the landmarks for predictions of the other different organ positions. However, the automated recognition of the bone structure is still a challenging issue. This research proposes an automated scheme for segmenting the bone regions and recognizing the bone structure in noncontrast torso CT images. The proposed scheme was applied to 48 torso CT cases and a subjective evaluation for the experimental results was carried out by an anatomical expert following the anatomical definition. The experimental results showed that the bone structure in 90% CT cases have been recognized correctly. For quantitative evaluation, automated recognition results were compared to manual inputs of bones of lower limb created by an anatomical expert on 10 randomly selected CT cases. The error (maximum distance in 3D) between the recognition results and manual inputs distributed from 3-8 mm in different parts of the bone regions.

  16. A comparison of methods to quantify the in-season training load of professional soccer players.

    PubMed

    Scott, Brendan R; Lockie, Robert G; Knight, Timothy J; Clark, Andrew C; Janse de Jonge, Xanne A K

    2013-03-01

    To compare various measures of training load (TL) derived from physiological (heart rate [HR]), perceptual (rating of perceived exertion [RPE]), and physical (global positioning system [GPS] and accelerometer) data during in-season field-based training for professional soccer. Fifteen professional male soccer players (age 24.9 ± 5.4 y, body mass 77.6 ± 7.5 kg, height 181.1 ± 6.9 cm) were assessed in-season across 97 individual training sessions. Measures of external TL (total distance [TD], the volume of low-speed activity [LSA; <14.4 km/h], high-speed running [HSR; >14.4 km/h], very high-speed running [VHSR; >19.8 km/h], and player load), HR and session-RPE (sRPE) scores were recorded. Internal TL scores (HR-based and sRPE-based) were calculated, and their relationships with measures of external TL were quantified using Pearson product-moment correlations. Physical measures of TD, LSA volume, and player load provided large, significant (r = .71-.84; P < .01) correlations with the HR-based and sRPE-based methods. Volume of HSR and VHSR provided moderate to large, significant (r = .40-.67; P < .01) correlations with measures of internal TL. While the volume of HSR and VHSR provided significant relationships with internal TL, physical-performance measures of TD, LSA volume, and player load appear to be more acceptable indicators of external TL, due to the greater magnitude of their correlations with measures of internal TL.

  17. Impact of extraneous mispositioned events on motion-corrected brain SPECT images of freely moving animals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Angelis, Georgios I., E-mail: georgios.angelis@sydney.edu.au; Ryder, William J.; Bashar, Rezaul

    Purpose: Single photon emission computed tomography (SPECT) brain imaging of freely moving small animals would allow a wide range of important neurological processes and behaviors to be studied, which are normally inhibited by anesthetic drugs or precluded due to the animal being restrained. While rigid body motion of the head can be tracked and accounted for in the reconstruction, activity in the torso may confound brain measurements, especially since motion of the torso is more complex (i.e., nonrigid) and not well correlated with that of the head. The authors investigated the impact of mispositioned events and attenuation due to themore » torso on the accuracy of motion corrected brain images of freely moving mice. Methods: Monte Carlo simulations of a realistic voxelized mouse phantom and a dual compartment phantom were performed. Each phantom comprised a target and an extraneous compartment which were able to move independently of each other. Motion correction was performed based on the known motion of the target compartment only. Two SPECT camera geometries were investigated: a rotating single head detector and a stationary full ring detector. The effects of motion, detector geometry, and energy of the emitted photons (hence, attenuation) on bias and noise in reconstructed brain regions were evaluated. Results: The authors observed two main sources of bias: (a) motion-related inconsistencies in the projection data and (b) the mismatch between attenuation and emission. Both effects are caused by the assumption that the orientation of the torso is difficult to track and model, and therefore cannot be conveniently corrected for. The motion induced bias in some regions was up to 12% when no attenuation effects were considered, while it reached 40% when also combined with attenuation related inconsistencies. The detector geometry (i.e., rotating vs full ring) has a big impact on the accuracy of the reconstructed images, with the full ring detector being more advantageous. Conclusions: Motion-induced inconsistencies in the projection data and attenuation/emission mismatch are the two main causes of bias in reconstructed brain images when there is complex motion. It appears that these two factors have a synergistic effect on the qualitative and quantitative accuracy of the reconstructed images.« less

  18. The analysis of the transient pressure response of the shuttle EPS-ECS cryogenic tanks with external pressurization systems

    NASA Technical Reports Server (NTRS)

    Barton, J. E.; Patterson, H. W.

    1973-01-01

    An analysis of transient pressures in externally pressurized cryogenic hydrogen and oxygen tanks was conducted and the effects of design variables on pressure response determined. The analysis was conducted with a computer program which solves the compressible viscous flow equations in two-dimensional regions representing the tank and external loop. The external loop volume, thermal mass, and heat leak were the dominant design variables affecting the system pressure response. No significant temperature stratification occurred in the fluid contained in the tank.

  19. A Hydrostatic Bearing Test System for Measuring Bearing Load Using Magnetic-Fluid Lubricants.

    PubMed

    Weng, Huei Chu; Chen, Lu-Yu

    2016-05-01

    This paper conducts a study on the design of a hydrostatic bearing test system. It involves the determination of viscous properties of magnetic-fluid lubricants. The load of a hydrostatic thrust bearing using a water-based magnetite nanofluid of varying volume flow rate is measured under an applied external induction field via the test system. Results reveal that the presence of nanoparticles in a carrier liquid would cause an enhanced bearing load. Such an effect could be further magnified by increasing the lubricant volume flow rate or the external induction field strength.

  20. A thermodynamic study of electroneutral K-Cl cotransport in pH- and volume-clamped low K sheep erythrocytes with normal and low internal magnesium.

    PubMed

    Lauf, P K; Adragna, N C

    1996-10-01

    Swelling-induced human erythrocyte K-Cl cotransport is membrane potential independent and capable of uphill transport. However, a complete thermodynamic analysis of basal and stimulated K-Cl cotransport, at constant cell volume, is missing. This study was performed in low K sheep red blood cells before and after reducing cellular free Mg into the nanomolar range with the divalent cation ionophore A23187 and a chelator, an intervention known to stimulate K-Cl cotransport. The anion exchange inhibitor 4,4'diisothiocyanato-2,2'disulfonic stilbene was used to clamp intracellular pH and Cl or NO3 concentrations. Cell volume was maintained constant as external and internal pH differed by more than two units. K-Cl cotransport was calculated from the K effluxes and Rb (as K congener) influxes measured in Cl and NO3, at constant internal K and external anions, and variable concentrations of extracellular Rb and internal anions, respectively. The external Rb concentration at which net K-Cl cotransport is zero was defined as flux reversal point which changed with internal pH and hence Cl. Plots of the ratio of external Rb concentrations corresponding to the flux reversal points and the internal K concentration versus the ratio of the internal and external Cl concentrations (i.e., the Donnan ratio of the transported ions) yielded slopes near unity for both control and low internal Mg cells. Thus, basal as well as low internal Mg-stimulated net K-Cl cotransport depends on the electrochemical potential gradient of KCl.

  1. A thermodynamic study of electroneutral K-Cl cotransport in pH- and volume-clamped low K sheep erythrocytes with normal and low internal magnesium

    PubMed Central

    1996-01-01

    Swelling-induced human erythrocyte K-Cl cotransport is membrane potential independent and capable of uphill transport. However, a complete thermodynamic analysis of basal and stimulated K-Cl cotransport, at constant cell volume, is missing. This study was performed in low K sheep red blood cells before and after reducing cellular free Mg into the nanomolar range with the divalent cation ionophore A23187 and a chelator, an intervention known to stimulate K- Cl cotransport. The anion exchange inhibitor 4,4'diisothiocyanato- 2,2'disulfonic stilbene was used to clamp intracellular pH and Cl or NO3 concentrations. Cell volume was maintained constant as external and internal pH differed by more than two units. K-Cl cotransport was calculated from the K effluxes and Rb (as K congener) influxes measured in Cl and NO3, at constant internal K and external anions, and variable concentrations of extracellular Rb and internal anions, respectively. The external Rb concentration at which net K-Cl cotransport is zero was defined as flux reversal point which changed with internal pH and hence Cl. Plots of the ratio of external Rb concentrations corresponding to the flux reversal points and the internal K concentration versus the ratio of the internal and external Cl concentrations (i.e., the Donnan ratio of the transported ions) yielded slopes near unity for both control and low internal Mg cells. Thus, basal as well as low internal Mg-stimulated net K-Cl cotransport depends on the electrochemical potential gradient of KCl. PMID:8894982

  2. Managing Organizational Change in the Community College. ERIC Digest.

    ERIC Educational Resources Information Center

    Kozeracki, Carol

    This digest discusses two recurrent themes presented in the New Directions for Community Colleges volume titled "Organizational Change in the Community College: Ripple or Sea Change?" First, change in the external environment is accelerating, and colleges must respond to these changes to thrive. External environmental influences include…

  3. Modeling of hot-mix asphalt compaction : a thermodynamics-based compressible viscoelastic model

    DOT National Transportation Integrated Search

    2010-12-01

    Compaction is the process of reducing the volume of hot-mix asphalt (HMA) by the application of external forces. As a result of compaction, the volume of air voids decreases, aggregate interlock increases, and interparticle friction increases. The qu...

  4. NASA historical data book. Volume 2: Programs and projects 1958-1968

    NASA Technical Reports Server (NTRS)

    Ezell, Linda Neuman

    1988-01-01

    This is Volume 2, Programs and Projects 1958-1968, of a multi-volume series providing a 20-year compilation of summary statistical and other data descriptive of NASA's programs in aeronautics and manned and unmanned spaceflight. This series is an important component of NASA published historical reference works, used by NASA personnel, managers, external researchers, and other government agencies.

  5. NASA historical data book. Volume 3: Programs and projects 1969-1978

    NASA Technical Reports Server (NTRS)

    Ezell, Linda Neuman

    1988-01-01

    This is Volume 3, Programs and Projects 1969-1978, of a multi-volume series providing a 20-year compilation of summary statistical and other data descriptive of NASA's programs in aeronautics and manned and unmanned spaceflight. This series is an important component of NASA published historical reference works, used by NASA personnel, managers, external researchers, and other government agencies.

  6. NASA historical data book. Volume 4: NASA resources 1969-1978

    NASA Technical Reports Server (NTRS)

    Gawdiak, Ihor Y.; Fedor, Helen

    1994-01-01

    This is Volume 4, NASA Resources 1969-1978, of a series providing a 20-year statistical summary of NASA programs. This series is an important component of NASA published historical reference works, used by NASA personnel, managers, external researchers, and other government agencies. This volume combines statistical data of the component facilities with the data of the parent installation.

  7. NASA historical data book. Volume 1: NASA resources 1958-1968

    NASA Technical Reports Server (NTRS)

    Vannimmen, Jane; Bruno, Leonard C.; Rosholt, Robert L.

    1988-01-01

    This is Volume 1, NASA Resources 1958-1968, of a multi-volume series providing a 20-year compilation of summary statistical and other data descriptive of NASA's programs in aeronautics and manned and unmanned spaceflight. This series is an important component of NASA published historical reference works, used by NASA personnel, managers, external researchers, and other government agencies.

  8. External validation of a forest inventory and analysis volume equation and comparisons with estimates from multiple stem-profile models

    Treesearch

    Christopher M. Oswalt; Adam M. Saunders

    2009-01-01

    Sound estimation procedures are desideratum for generating credible population estimates to evaluate the status and trends in resource conditions. As such, volume estimation is an integral component of the U.S. Department of Agriculture, Forest Service, Forest Inventory and Analysis (FIA) program's reporting. In effect, reliable volume estimation procedures are...

  9. 49 CFR 180.203 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... (e.g. chemical stress corrosion). Condemn means a determination that a cylinder is unserviceable for... using the water jacket or direct expansion methods: (1) Water jacket method means a volumetric expansion... volume of water the cylinder externally displaces at test pressure and the volume of water the cylinder...

  10. Research Technology

    NASA Image and Video Library

    2002-08-05

    The Bonner Ball Neutron Detector measures neutron radiation. Neutrons are uncharged atomic particles that have the ability to penetrate living tissues, harming human beings in space. The Bonner Ball Neutron Detector is one of three radiation experiments during Expedition Two. The others are the Phantom Torso and Dosimetric Mapping.

  11. 49 CFR 572.84 - Thorax.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... OF TRANSPORTATION (CONTINUED) ANTHROPOMORPHIC TEST DEVICES 9-Month Old Child § 572.84 Thorax. The thorax consists of the part of the torso shown in assembly drawing LP 1049/A and conforms to each of the applicable drawings listed under LP 1049/0 through 54. ...

  12. 49 CFR 571.216a - Standard No. 216a; Roof crush resistance; Upgraded standard.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., 1200 New Jersey Avenue, Washington, DC 20590, or at the National Archives and Records Administration... SAE J826 (July 1995) (two from the left side and two from the right side), replace with two HRMD torso...

  13. Outflow monitoring of a pneumatic ventricular assist device using external pressure sensors.

    PubMed

    Kang, Seong Min; Her, Keun; Choi, Seong Wook

    2016-08-25

    In this study, a new algorithm was developed for estimating the pump outflow of a pneumatic ventricular assist device (p-VAD). The pump outflow estimation algorithm was derived from the ideal gas equation and determined the change in blood-sac volume of a p-VAD using two external pressure sensors. Based on in vitro experiments, the algorithm was revised to consider the effects of structural compliance caused by volume changes in an implanted unit, an air driveline, and the pressure difference between the sensors and the implanted unit. In animal experiments, p-VADs were connected to the left ventricles and the descending aorta of three calves (70-100 kg). Their outflows were estimated using the new algorithm and compared to the results obtained using an ultrasonic blood flow meter (UBF) (TS-410, Transonic Systems Inc., Ithaca, NY, USA). The estimated and measured values had a Pearson's correlation coefficient of 0.864. The pressure sensors were installed at the external controller and connected to the air driveline on the same side as the external actuator, which made the sensors easy to manage.

  14. Experimental Study on the Dielectric Breakdown Voltage of the Insulating Oil Mixed with Magnetic Nanoparticles

    NASA Astrophysics Data System (ADS)

    Lee, Jong-Chul; Kim, Woo-Young

    In this study, we have measured the dielectric breakdown voltage of transformer oil-based nanofluids in accordance with IEC 156 standard and have investigated the dielectric breakdown performance with the application of an external magnetic field and different volume concentrations of magnetic nanoparticles. It is confirmed that the dielectric breakdown voltage of pure transformer oil is about 10 kV with a gap distance of 1 mm between electrodes. In the case of our transformer oil-based nanofluids with 0.08% < Φ < 0.39% (Φ means the volume concentration of magnetic nanoparticles in the fluid), the dielectric breakdown voltage is three times higher than that of pure transformer oil. Furthermore, when the external magnetic field is applied under the experimental vessel, the dielectric breakdown voltage of the nanofluids is above 40 kV, which is 30% higher than that without the external magnetic field.

  15. Comparison of the metabolic demands of dance performance using three mobility devices for a dancer with spinal cord injury and an able-bodied dancer.

    PubMed

    Mengelkoch, Larry J; Highsmith, M Jason; Morris, Merry L

    2014-09-01

    Mobility devices for dancers with physical mobility impairments have previously been limited to traditional manual or power wheelchairs. The hands-free torso-controlled mobility chair is a unique powered mobility device which allows greater freedom and expression of movement of the trunk and upper extremities. This study compared differences in energy expenditure during a standardized dance activity using three mobility devices: the hands-free torso-controlled mobility chair, a manual sports wheelchair with hand-arm control, and an electric power chair with hand-joystick control. An experienced dancer with C7 incomplete spinal cord injury (SCI) and an experienced able-bodied dancer were recruited for testing. Three measurement trials were obtained for each chair per subject. Oxygen uptake (VO2) and heart rate (HR) were measured continuously during the dance activity. Immediately following the dance activity, subjects rated perceived exertion. Significant differences (p ≤ 0.05) and similar linear patterns in VO2 and HR responses were observed between chairs for both dancers. When the hands-free mobility chair was used, the dance activity required a moderate level of energy expenditure compared to the manual sports chair or electric power chair for both dancers. Higher ratings of perceived exertion were observed in the manual chair compared to the other chairs for the dancer with SCI, but were similar between chairs for the able-bodied dancer. These results suggest that for a dancer with high-level SCI, the hands-free torso-controlled mobility chair may offer improved freedom and expressive movement possibilities and is an energy-efficient mobility device.

  16. Automated abdominal plane and circumference estimation in 3D US for fetal screening

    NASA Astrophysics Data System (ADS)

    Lorenz, C.; Brosch, T.; Ciofolo-Veit, C.; Klinder, T.; Lefevre, T.; Cavallaro, A.; Salim, I.; Papageorghiou, A. T.; Raynaud, C.; Roundhill, D.; Rouet, L.; Schadewaldt, N.; Schmidt-Richberg, A.

    2018-03-01

    Ultrasound is increasingly becoming a 3D modality. Mechanical and matrix array transducers are able to deliver 3D images with good spatial and temporal resolution. The 3D imaging facilitates the application of automated image analysis to enhance workflows, which has the potential to make ultrasound a less operator dependent modality. However, the analysis of the more complex 3D images and definition of all examination standards on 2D images pose barriers to the use of 3D in daily clinical practice. In this paper, we address a part of the canonical fetal screening program, namely the localization of the abdominal cross-sectional plane with the corresponding measurement of the abdominal circumference in this plane. For this purpose, a fully automated pipeline has been designed starting with a random forest based anatomical landmark detection. A feature trained shape model of the fetal torso including inner organs with the abdominal cross-sectional plane encoded into the model is then transformed into the patient space using the landmark localizations. In a free-form deformation step, the model is individualized to the image, using a torso probability map generated by a convolutional neural network as an additional feature image. After adaptation, the abdominal plane and the abdominal torso contour in that plane are directly obtained. This allows the measurement of the abdominal circumference as well as the rendering of the plane for visual assessment. The method has been trained on 126 and evaluated on 42 abdominal 3D US datasets. An average plane offset error of 5.8 mm and an average relative circumference error of 4.9 % in the evaluation set could be achieved.

  17. Exposure of the examiner to radiation during myelography versus radiculography and root block: A comparative study.

    PubMed

    Yamane, Kentaro; Kai, Nobuo; Miyamoto, Tadashi; Matsushita, Tomohiro

    2017-03-01

    Exposure to radiation over many years prompts concerns regarding potential health-related effects, particularly the incidence of cataracts and the development of cancer. The purpose of this study was to examine and compare the exposure of the examiner to radiation during myelography versus radiculography and root block. A total of 114 examinations were performed in our institute in the 6 months. Sixty-two examinations were performed during myelography in the first 3 months (MG group), while 52 were performed during radiculography and root block in the last 3 months (RB group). The examiner wore a torso protector, a neck protector, radiation protection gloves, and radiation protection glasses. Optically stimulated luminescence (OSL) dosimeter badges were placed on both the inside and the outside of each protector. The dosimeters were exchanged every month. Radiation doses (mSv) were measured as the integrated radiation quantity every month from the OSL dosimeters. The effective dose and the equivalent doses of hand, skin, and eyes were investigated. The mean equivalent doses were significantly lower outside the neck, torso, eye protectors, and inside the torso protector in the RB group than in the MG group. Conversely, the mean equivalent dose was significantly lower outside the hand protector in the MG group than in the RB group. The use of a neck protector significantly decreased the effective dose compared to the non-use of a neck protector in the RB group. The present study showed the standard radiation exposure to the examiner during myelography, radiculography, and root block. Receiving full protection including a neck protector and protection gloves is an easy and reliable means to reduce radiation exposure. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  18. Regional thermal comfort zone in males and females.

    PubMed

    Ciuha, Ursa; Mekjavic, Igor B

    2016-07-01

    Skin regions differ in their sensitivity to temperature stimuli. The present study examined whether such regional differences were also evident in the perception of thermal comfort. Regional thermal comfort was assessed in males (N=8) and females (N=8), by having them regulate the temperature of the water delivered to a water-perfused suit (WPS), within a temperature range considered thermally comfortable. In separate trials, subjects regulated the temperature of the WPS, or specific regions of the suit covering different skin areas (arms, legs, front torso and back torso). In the absence of subjective temperature regulation (TR), the temperature changed in a sinusoidal manner from 10°C to 50°C; by depressing a switch and reversing the direction of the temperature at the limits of the thermal comfort zone (TCZ), each subject defined TCZ for each body region investigated. The range of regulated temperatures did not differ between genders and skin regions. Local Tsk at the lower and upper limits of the TCZ was similar for both genders. Higher (p<0.05) local Tsk was preferred for the arms (35.4±2.1°C), compared to other regions (legs: 34.4±5.4°C, front torso: 34.6±2.8°C, 34.3±6.6°C), irrespective of gender. In thermally comfortable conditions, the well-established regional differences in thermosensitivity are not reflected in the TCZ, with similar temperature preferences by both genders. Thermal comfort of different skin regions and overall body is not achieved at a single skin temperature, but at range of temperatures, defined as the TCZ. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Biomechanical analysis of materials handling manipulators in short distance transfers of moderate mass objects: joint strength, spine forces and muscular antagonism.

    PubMed

    Nussbaum, M A; Chaffin, D B; Baker, G

    1999-12-01

    Although often suggested as a control measure to alleviate musculoskeletal stresses, the use of mechanical assistance devices (i.e. manipulators) in load transfers has not been extensively studied. Without data describing the biomechanical effects of such devices, justification for decisions regarding implementation of such tools is difficult. An experimental study of two types of mechanical manipulators (articulated arm and overhead hoist) was conducted to determine whether biomechanical stresses, and hence injury risk, would be alleviated. Short distance transfers of loads with moderate mass were performed both manually and with manipulator assistance under a variety of task conditions. Using analysis and output from new dynamic torso models, strength demands at the shoulders and low back, lumbar spine forces, and lumbar muscle antagonism were determined. Strength requirements decreased significantly at both the shoulders and low back when using either manipulator in comparison with similar transfers performed manually. Peak spine compression and anterior-posterior (a-p) shear forces were reduced by about 40% on average, and these reductions were shown to be primarily caused by decreases in hand forces and resultant spinal moments. Two metrics of muscular antagonism were defined, and analysis showed that torso muscle antagonism was largest overall when using the hoist. The results overall suggest that hoist-assisted transfers, although better in reducing spine compression forces, may impose relatively higher demands on coordination and/or stability at extreme heights or with torso twisting motions. The relatively higher strength requirements and spine compression associated with the articulated arm may be a result of the high inertia of the system. Potential benefits of practice and training are discussed, and conclusions regarding implementation of mechanical manipulators are given.

  20. Oxygenation of the Intraportally Transplanted Pancreatic Islet

    PubMed Central

    2016-01-01

    Intraportal islet transplantation (IT) is not widely utilized as a treatment for type 1 diabetes. Oxygenation of the intraportally transplanted islet has not been studied extensively. We present a diffusion-reaction model that predicts the presence of an anoxic core and a larger partly functional core within intraportally transplanted islets. Four variables were studied: islet diameter, islet fractional viability, external oxygen partial pressure (P) (in surrounding portal blood), and presence or absence of a thrombus on the islet surface. Results indicate that an islet with average size and fractional viability exhibits an anoxic volume fraction (AVF) of 14% and a function loss of 72% at a low external P. Thrombus formation increased AVF to 30% and function loss to 92%, suggesting that the effect of thrombosis may be substantial. External P and islet diameter accounted for the greatest overall impact on AVF and loss of function. At our institutions, large human alloislets (>200 μm diameter) account for ~20% of total islet number but ~70% of total islet volume; since most of the total transplanted islet volume is accounted for by large islets, most of the intraportal islet cells are likely to be anoxic and not fully functional. PMID:27872862

  1. Oxygenation of the Intraportally Transplanted Pancreatic Islet.

    PubMed

    Suszynski, Thomas M; Avgoustiniatos, Efstathios S; Papas, Klearchos K

    2016-01-01

    Intraportal islet transplantation (IT) is not widely utilized as a treatment for type 1 diabetes. Oxygenation of the intraportally transplanted islet has not been studied extensively. We present a diffusion-reaction model that predicts the presence of an anoxic core and a larger partly functional core within intraportally transplanted islets. Four variables were studied: islet diameter, islet fractional viability, external oxygen partial pressure ( P ) (in surrounding portal blood), and presence or absence of a thrombus on the islet surface. Results indicate that an islet with average size and fractional viability exhibits an anoxic volume fraction (AVF) of 14% and a function loss of 72% at a low external P . Thrombus formation increased AVF to 30% and function loss to 92%, suggesting that the effect of thrombosis may be substantial. External P and islet diameter accounted for the greatest overall impact on AVF and loss of function. At our institutions, large human alloislets (>200 μ m diameter) account for ~20% of total islet number but ~70% of total islet volume; since most of the total transplanted islet volume is accounted for by large islets, most of the intraportal islet cells are likely to be anoxic and not fully functional.

  2. Development of multivariate NTCP models for radiation-induced hypothyroidism: a comparative analysis.

    PubMed

    Cella, Laura; Liuzzi, Raffaele; Conson, Manuel; D'Avino, Vittoria; Salvatore, Marco; Pacelli, Roberto

    2012-12-27

    Hypothyroidism is a frequent late side effect of radiation therapy of the cervical region. Purpose of this work is to develop multivariate normal tissue complication probability (NTCP) models for radiation-induced hypothyroidism (RHT) and to compare them with already existing NTCP models for RHT. Fifty-three patients treated with sequential chemo-radiotherapy for Hodgkin's lymphoma (HL) were retrospectively reviewed for RHT events. Clinical information along with thyroid gland dose distribution parameters were collected and their correlation to RHT was analyzed by Spearman's rank correlation coefficient (Rs). Multivariate logistic regression method using resampling methods (bootstrapping) was applied to select model order and parameters for NTCP modeling. Model performance was evaluated through the area under the receiver operating characteristic curve (AUC). Models were tested against external published data on RHT and compared with other published NTCP models. If we express the thyroid volume exceeding X Gy as a percentage (Vx(%)), a two-variable NTCP model including V30(%) and gender resulted to be the optimal predictive model for RHT (Rs = 0.615, p < 0.001. AUC = 0.87). Conversely, if absolute thyroid volume exceeding X Gy (Vx(cc)) was analyzed, an NTCP model based on 3 variables including V30(cc), thyroid gland volume and gender was selected as the most predictive model (Rs = 0.630, p < 0.001. AUC = 0.85). The three-variable model performs better when tested on an external cohort characterized by large inter-individuals variation in thyroid volumes (AUC = 0.914, 95% CI 0.760-0.984). A comparable performance was found between our model and that proposed in the literature based on thyroid gland mean dose and volume (p = 0.264). The absolute volume of thyroid gland exceeding 30 Gy in combination with thyroid gland volume and gender provide an NTCP model for RHT with improved prediction capability not only within our patient population but also in an external cohort.

  3. Analysis of Head Response to Torso Acceleration. Vol. I - Development of Performance Requirements.

    DOT National Transportation Integrated Search

    1987-11-01

    Performance requirements are developed which define the kinematic and kinetic response of the head for a seated subject exposed to frontal, lateral or oblique impact. Response is expressed in terms of variables which are readily measured in an anthro...

  4. Borner Ball Neutron Detector

    NASA Technical Reports Server (NTRS)

    2002-01-01

    The Bonner Ball Neutron Detector measures neutron radiation. Neutrons are uncharged atomic particles that have the ability to penetrate living tissues, harming human beings in space. The Bonner Ball Neutron Detector is one of three radiation experiments during Expedition Two. The others are the Phantom Torso and Dosimetric Mapping.

  5. Hopkins in the A/L

    NASA Image and Video Library

    2013-12-18

    View of Mike Hopkins, Expedition 38 Flight Engineer (FE), during remove and replace (R&R) of Hard Upper Torso (HUT) of Extravehicular Mobility Unit (EMU), in the airlock (A/L) during preparation for EVA-24. Photo was taken during Expedition 38. Image was released by astronaut on Twitter.

  6. Combat Injury Coding: A Review and Reconfiguration

    DTIC Science & Technology

    2013-01-01

    the clavicle , scapula, and pelvic girdle were grouped with the torso where they are anatomically located rather than in the upper and lower extremities...incomplete return to previous cognitive state Clavicle or scapula fracture, unilateral Burns, second or third degree, hand, wrist, elbow or shoulder

  7. Wearing an abdominal belt increases diastolic blood pressure.

    PubMed

    Rafacz, W; McGill, S M

    1996-09-01

    The purpose of this study was to determine the effect of wearing an abdominal belt on blood pressure (systolic and diastolic) and heart rate during a variety of tasks. The belt was typical of the elastic type with suspenders and Velcro tabs for cinching the belt snug. The tasks performed included sitting at rest, sitting with the torso inclined forward at 45 degrees, standing with the torso inclined forward at 45 degrees (with and without holding an 11-kg weight), a trunk axial rotation task, and squat lifting. Blood pressure was monitored noninvasively with a FINAPRES blood pressure monitor. Twenty healthy men performed each task with and without the abdominal belt. Although no significant increases in mean systolic blood pressure or heart rate were found, there was a significant increase in diastolic blood pressure in all conditions. All people considering wearing an abdominal belt should also consider the risks and liability associated with the additional cardiovascular load, particularly heart attack and stroke.

  8. Shoulder and hip joint for hard space suits

    NASA Technical Reports Server (NTRS)

    Vykukal, H. C.

    1986-01-01

    Shoulder and hip joints for hard space suits are disclosed which are comprised of three serially connected truncated spherical sections, the ends of which converge. Ball bearings between the sections permit relative rotation. The proximal end of the first section is connected to the torso covering by a ball bearing and the distal end of the outermost section is connected to the elbow or thigh covering by a ball bearing. The sections are equi-angular and this alleviates lockup, the condition where the distal end of the joint leaves the plane in which the user is attempting to flex. The axes of rotation of the bearings and the bearing mid planes are arranged to intersect in a particular manner that provides the joint with a minimum envelope. In one embodiment, the races of the bearing between the innermost section and the second section is partially within the inner race of the bearing between the torso and the innermost spherical section further to reduce bulk.

  9. The effect of over-commitment and reward on trapezius muscle activity and shoulder, head, neck, and torso postures during computer use in the field

    PubMed Central

    Bruno Garza, Jennifer L.; Eijckelhof, Belinda H.W.; Huysmans, Maaike A.; Catalano, Paul J.; Katz, Jeffrey N.; Johnson, Peter W.; van Dieen, Jaap H.; van der Beek, Allard J.; Dennerlein, Jack T.

    2015-01-01

    Background Because of reported associations of psychosocial factors and computer related musculoskeletal symptoms, we investigated the effects of a workplace psychosocial factor, reward, in the presence of over-commitment, on trapezius muscle activity and shoulder, head, neck, and torso postures during computer use. Methods We measured 120 office workers across four groups (lowest/highest reward/over-commitment), performing their own computer work at their own workstations over a 2 hour period. Results Median trapezius muscle activity (p=0.04) and median neck flexion (p=0.03) were largest for participants reporting simultaneously low reward and high over-commitment. No differences were observed for other muscle activities or postures. Conclusions These data suggest that the interaction of reward and over-commitment can affect upper extremity muscle activity and postures during computer use in the real work environment. This finding aligns with the hypothesized biomechanical pathway connecting workplace psychosocial factors and musculoskeletal symptoms of the neck and shoulder. PMID:23818000

  10. High Performance Mars Liquid Cooling and Ventilation Garment Project

    NASA Technical Reports Server (NTRS)

    Terrier, Douglas; Clayton, Ronald; Whitlock, David; Conger, Bruce

    2015-01-01

    EVA space suit mobility in micro-gravity is enough of a challenge and in the gravity of Mars, improvements in mobility will enable the suited crew member to efficiently complete EVA objectives. The idea proposed is to improve thermal efficiencies of the liquid cooling and ventilation garment (LCVG) in the torso area in order to free up the arms and legs by removing the liquid tubes currently used in the ISS EVA suit in the limbs. By using shaped water tubes that greatly increase the contact area with the skin in the torso region of the body, the heat transfer efficiency can be increased to provide the entire liquid cooling requirement and increase mobility by freeing up the arms and legs. Additional potential benefits of this approach include reduced LCVG mass, enhanced evaporation cooling, increased comfort during Mars EVA tasks, and easing of the overly dry condition in the helmet associated with the Advanced Extravehicular Mobility Unit (EMU) ventilation loop currently under development.

  11. Assessment of Suited Reach Envelope in an Underwater Environment

    NASA Technical Reports Server (NTRS)

    Kim, Han; Benson, Elizabeth; Bernal, Yaritza; Jarvis, Sarah; Meginnis, Ian; Rajulu, Sudhakar

    2017-01-01

    Predicting the performance of a crewmember in an extravehicular activity (EVA) space suit presents unique challenges. The kinematic patterns of suited motions are difficult to reproduce in gravity. Additionally, 3-D suited kinematics have been practically and technically difficult to quantify in an underwater environment, in which crewmembers are commonly trained and assessed for performance. The goal of this study is to develop a hardware and software system to predictively evaluate the kinematic mobility of suited crewmembers, by measuring the 3-D reach envelope of the suit in an underwater environment. This work is ultimately aimed at developing quantitative metrics to compare the mobility of the existing Extravehicular Mobility Unit (EMU) to newly developed space suit, such as the Z-2. The EMU has been extensively used at NASA since 1981 for EVA outside the Space Shuttle and International Space Station. The Z-2 suit is NASA's newest prototype space suit. The suit is comprised of new upper torso and lower torso architectures, which were designed to improve test subject mobility.

  12. A multiantioxidant supplementation reduces damage from ischaemia reperfusion in patients after lower torso ischaemia. A randomised trial.

    PubMed

    Wijnen, M H W A; Roumen, R M H; Vader, H L; Goris, R J A

    2002-06-01

    open repair of intra-abdominal aortic aneurysm (AAA) is associated with lower torso ischaemia and reperfusion. to examine the effect of antioxidants on the activation and sequestration of white blood cells and muscle injury during AAA repair. forty-two patients undergoing elective infrarenal aneurysm repair, were randomised to either standard therapy (22 patients) or standard therapy with additional multiantioxidant supplementation (20 patients). Vitamin E and C, Allopurinol, N-acetylcysteine and mannitol was administered perioperatively. White blood cell count (WBC), serum creatine kinase, aspartateaminotransferase, lactate and lipofuscine were measured. WBC remained higher after reperfusion in the antioxidant group (p = 0.008). CK, ASAT and lipofuscine levels were significantly lower after reperfusion in the antioxidant group (p = 0.02, p = 0.018, p = 0.017). multi-antioxidant supplementation was associated with a reduction in serum CK and ASAT after AAA repair. This is likely due to a reduction in oxidative stress and a decreased leucocyte sequestration and activation. Copyright 2002 Elsevier Science Ltd.

  13. The MATROSHKA experiment: results and comparison from extravehicular activity (MTR-1) and intravehicular activity (MTR-2A/2B) exposure.

    PubMed

    Berger, Thomas; Bilski, Paweł; Hajek, Michael; Puchalska, Monika; Reitz, Günther

    2013-12-01

    Astronauts working and living in space are exposed to considerably higher doses and different qualities of ionizing radiation than people on Earth. The multilateral MATROSHKA (MTR) experiment, coordinated by the German Aerospace Center, represents the most comprehensive effort to date in radiation protection dosimetry in space using an anthropomorphic upper-torso phantom used for radiotherapy treatment planning. The anthropomorphic upper-torso phantom maps the radiation distribution as a simulated human body installed outside (MTR-1) and inside different compartments (MTR-2A: Pirs; MTR-2B: Zvezda) of the Russian Segment of the International Space Station. Thermoluminescence dosimeters arranged in a 2.54 cm orthogonal grid, at the site of vital organs and on the surface of the phantom allow for visualization of the absorbed dose distribution with superior spatial resolution. These results should help improve the estimation of radiation risks for long-term human space exploration and support benchmarking of radiation transport codes.

  14. Cervix regression and motion during the course of external beam chemoradiation for cervical cancer.

    PubMed

    Beadle, Beth M; Jhingran, Anuja; Salehpour, Mohammad; Sam, Marianne; Iyer, Revathy B; Eifel, Patricia J

    2009-01-01

    To evaluate the magnitude of cervix regression and motion during external beam chemoradiation for cervical cancer. Sixteen patients with cervical cancer underwent computed tomography scanning before, weekly during, and after conventional chemoradiation. Cervix volumes were calculated to determine the extent of cervix regression. Changes in the center of mass and perimeter of the cervix between scans were used to determine the magnitude of cervix motion. Maximum cervix position changes were calculated for each patient, and mean maximum changes were calculated for the group. Mean cervical volumes before and after 45 Gy of external beam irradiation were 97.0 and 31.9 cc, respectively; mean volume reduction was 62.3%. Mean maximum changes in the center of mass of the cervix were 2.1, 1.6, and 0.82 cm in the superior-inferior, anterior-posterior, and right-left lateral dimensions, respectively. Mean maximum changes in the perimeter of the cervix were 2.3 and 1.3 cm in the superior and inferior, 1.7 and 1.8 cm in the anterior and posterior, and 0.76 and 0.94 cm in the right and left lateral directions, respectively. Cervix regression and internal organ motion contribute to marked interfraction variations in the intrapelvic position of the cervical target in patients receiving chemoradiation for cervical cancer. Failure to take these variations into account during the application of highly conformal external beam radiation techniques poses a theoretical risk of underdosing the target or overdosing adjacent critical structures.

  15. The interrelationship of the thorax and pelvis under varying task constraints.

    PubMed

    Delphinus, Elias M; Sayers, Mark Gregory Leigh

    2013-01-01

    The purpose of this study was to investigate the interrelationship between the thorax and pelvis during coupled movement patterns. Fifty-seven participants were assessed using an infrared motion analysis system to track trunk movement during maximal pelvis and thorax rotations over four trunk inclinations and two pelvic constraint conditions. A repeated-measures multivariate analysis of variance investigated the effects of forward trunk inclination and pelvic constraint on thorax and pelvic rotation. Forward trunk inclination from neutral to 45° resulted in a 46% (p < 0.001) decrease in axial pelvic rotation and a 15% (p < 0.001) decrease in axial thorax rotation with an unconstrained pelvis. A constrained pelvis resulted in a 15% (p < 0.001) decrease in axial thorax rotation. An externally constrained pelvis allowed the thorax to achieve an average of 18° (SD = 2°) greater rotational range of motion across all angles. This study reinforced the importance of allowing the pelvis to rotate during whole body axial rotation tasks. Results indicated that maximum axial trunk rotation is best achieved in a neutral posture, when the pelvis is allowed to contribute and flexion at the hips should be minimised. For example, if a recumbent task requires rotation of the torso, then the chair seat should be allowed to swivel.

  16. Application of long-period-grating sensors to respiratory plethysmography.

    PubMed

    Allsop, Thomas; Carroll, Karen; Lloyd, Glynn; Webb, David J; Miller, Martin; Bennion, Ian

    2007-01-01

    A series of in-line curvature sensors on a garment are used to monitor the thoracic and abdominal movements of a human during respiration. These results are used to obtain volumetric tidal changes of the human torso in agreement with a spirometer used simultaneously at the mouth. The curvature sensors are based on long-period gratings (LPGs) written in a progressive three-layered fiber to render the LPGs insensitive to the refractive index external to the fiber. A curvature sensor consists of the fiber long-period grating laid on a carbon fiber ribbon, which is then encapsulated in a low-temperature curing silicone rubber. The sensors have a spectral sensitivity to curvature, d lambda/dR from approximately 7-nm m to approximately 9-nm m. The interrogation technique is borrowed from derivative spectroscopy and monitors the changes in the transmission spectral profile of the LPG's attenuation band due to curvature. The multiplexing of the sensors is achieved by spectrally matching a series of distributed feedback (DFB) lasers to the LPGs. The versatility of this sensing garment is confirmed by it being used on six other human subjects covering a wide range of body mass indices. Just six fully functional sensors are required to obtain a volumetric error of around 6%.

  17. Comparative Analysis of the Tour Jete and Aerial with Detailed Analysis of Aerial Takeoff Mechanics

    NASA Astrophysics Data System (ADS)

    Pierson, Mimi; Coplin, Kim

    2006-10-01

    Whether internally as muscle tension or from external sources, forces are necessary for all motion. This research focused on athletic rotations where conditions of flight are established during takeoff. By studying reaction forces that produce torques, moments of inertia, and linear and angular differences between distinct rotations around different principle axes of the body (tour jete in ballet - longitudinal axis; aerial in gymnastics - anteroposterior axis), and by looking at the values of angular momentum in the specific mechanics of aerial takeoff, we can gain insight into possible causes of injury, flaws in technique and limitations of athletes. Results showed significant differences in the horizontal and vertical components of takeoff between the tour jete and the aerial, and a realization that torque was produced in different biomechanical planes. Both rotations showed braking forces before takeoff to counteract forward momentum and increase vertical lift, but the angle of applied force varied, and the horizontal components of velocity and force and vertical velocity as well as moment of inertia throughout flight were consistently greater for the aerial. Breakdown of aerial takeoff highlighted the relative importance of the takeoff phases, showing that completion depends fundamentally upon the rotation of the rear foot and torso twisting during takeoff rather than the last foot in contact with the ground.

  18. Fetomaternal hemorrhage during external cephalic version.

    PubMed

    Boucher, Marc; Marquette, Gerald P; Varin, Jocelyne; Champagne, Josette; Bujold, Emmanuel

    2008-07-01

    To estimate the frequency and volume of fetomaternal hemorrhage during external cephalic version for term breech singleton fetuses and to identify risk factors involved with this complication. A prospective observational study was performed including all patients undergoing a trial of external cephalic version for a breech presentation of at least 36 weeks of gestation between 1987 and 2001 in our center. A search for fetal erythrocytes using the standard Kleihauer-Betke test was obtained before and after each external cephalic version. The frequency and volume of fetomaternal hemorrhage were calculated. Putative risk factors for fetomaternal hemorrhage were evaluated by chi(2) test and Mann-Whitney U test. A Kleihauer-Betke test result was available before and after 1,311 trials of external cephalic version. The Kleihauer-Betke test was positive in 67 (5.1%) before the procedure. Of the 1,244 women with a negative Kleihauer-Betke test before external cephalic version, 30 (2.4%) had a positive Kleihauer-Betke test after the procedure. Ten (0.8%) had an estimated fetomaternal hemorrhage greater than 1 mL, and one (0.08%) had an estimated fetomaternal hemorrhage greater than 30 mL. The risk of fetomaternal hemorrhage was not influenced by parity, gestational age, body mass index, number of attempts at version, placental location, or amniotic fluid index. The risk of detectable fetomaternal hemorrhage during external cephalic version was 2.4%, with fetomaternal hemorrhage more than 30 mL in less than 0.1% of cases. These data suggest that the performance of a Kleihauer-Betke test is unwarranted in uneventful external cephalic version and that in Rh-negative women, no further Rh immune globulin is necessary other than the routine 300-microgram dose at 28 weeks of gestation and postpartum. II.

  19. Implementation of image-guided brachytherapy (IGBT) for patients with uterine cervix cancer: a tumor volume kinetics approach.

    PubMed

    Carvalho, Heloisa de Andrade; Mendez, Lucas Castro; Stuart, Silvia Radwanski; Guimarães, Roger Guilherme Rodrigues; Ramos, Clarissa Cerchi Angotti; de Paula, Lucas Assad; de Sales, Camila Pessoa; Chen, André Tsin Chih; Blasbalg, Roberto; Baroni, Ronaldo Hueb

    2016-08-01

    To evaluate tumor shrinking kinetics in order to implement image-guided brachytherapy (IGBT) for the treatment of patients with cervix cancer. This study has prospectively evaluated tumor shrinking kinetics of thirteen patients with uterine cervix cancer treated with combined chemoradiation. Four high dose rate brachytherapy fractions were delivered during the course of pelvic external beam radiation therapy (EBRT). Magnetic resonance imaging (MRI) exams were acquired at diagnosis (D), first (B1), and third (B3) brachytherapy fractions. Target volumes (GTV and HR-CTV) were calculated by both the ellipsoid formula (VE) and MRI contouring (VC), which were defined by a consensus between at least two radiation oncologists and a pelvic expert radiologist. Most enrolled patients had squamous cell carcinoma and FIGO stage IIB disease, and initiated brachytherapy after the third week of pelvic external beam radiation. Gross tumor volume volume reduction from diagnostic MRI to B1 represented 61.9% and 75.2% of the initial volume, when measured by VE and VC, respectively. Only a modest volume reduction (15-20%) was observed from B1 to B3. The most expressive tumor shrinking occurred in the first three weeks of oncological treatment and was in accordance with gynecological examination. These findings may help in IGBT implementation.

  20. External tank aerothermal design criteria verification, volume 2

    NASA Technical Reports Server (NTRS)

    Crain, William K.; Frost, Cynthia; Warmbrod, John

    1990-01-01

    The objective of the study was to produce an independent set of ascent environments which would serve as a check on the Rockwell International (RI) IVBC-3 environments and provide an independent reevaluation of the thermal design criteria for the External Tank (ET). Given here are the plotted timewise environments comparing REMTECH results to the RI IVBC results.

  1. High-Volume Repeaters of Self-Harm.

    PubMed

    Ness, Jennifer; Hawton, Keith; Bergen, Helen; Waters, Keith; Kapur, Navneet; Cooper, Jayne; Steeg, Sarah; Clarke, Martin

    2016-11-01

    Repetition of self-harm is common and is strongly associated with suicide. Despite this, there is limited research on high-volume repetition. To investigate individuals with high-volume repeat self-harm attendances to the emergency department (ED), including their patterns of attendance and mortality. Data from the Multicentre Study of Self-Harm in England were used. High-volume repetition was defined as ⩾15 attendances within 4 years. An attendance timeline was constructed for each high-volume repeater (HVR) and the different patterns of attendance were explored using an executive sorting task and hierarchical cluster analysis. A small proportion of self-harm patients are HVRs (0.6%) but they account for a large percentage of self-harm attendances (10%). In this study, the new methodological approach resulted in three types of attendance patterns. All of the HVRs had clusters of attendance and a greater proportion died from external causes compared with non-HVRs. The approach used in this study offers a new method for investigating this problem that could have both clinical and research benefits. The need for early intervention is highlighted by the large number of self-harm episodes per patient, the clustered nature of attendances, and the higher prevalence of death from external causes.

  2. Windsurfing Injuries: Added Awareness for Diagnosis, Treatment, and Prevention.

    ERIC Educational Resources Information Center

    Rosenbaum, Daryl A.; Dietz, Thomas E.

    2002-01-01

    With proper training and safety precautions, windsurfing is relatively safe, but its unique equipment and unpredictable environmental conditions can produce serious injuries. Clinicians may see fall-related ankle injuries, tarsometatarsal injuries, or anterior shoulder dislocations; chronic low-back pain from torso stress; skin lacerations; and…

  3. Camouflage, Color Schemes, and Cubism.

    ERIC Educational Resources Information Center

    Guhin, Paula

    2002-01-01

    Presents an art activity where students learn about Cubism and color mixing. Explains that the students create camouflaged animals after learning about the work, "Female Torso" (Pablo Picasso). Includes directions for how to create the pictures and states that the assignment can be used with students of all ages. (CMK)

  4. Comparing Blast Effects on Human Torso Finite Element Model against Existing Lethality Curves

    DTIC Science & Technology

    2010-07-15

    vertebrae, intervertebral discs, ribs, cartilage, sternum, scapula, and clavicle . The internal organs include the heart and aorta, lungs and trachea...Thoracic Vertebrae  Intervertebral Disc  Scapula  Clavicle Heritage Style Viewgraphs6 HTFEM Development Internal Organs Ten-noded tetrahedral

  5. Evaluation of pediatric ATD biofidelity as compared to child volunteers in low-speed far-side oblique and lateral impacts.

    PubMed

    Seacrist, Thomas; Locey, Caitlin M; Mathews, Emily A; Jones, Dakota L; Balasubramanian, Sriram; Maltese, Matthew R; Arbogast, Kristy B

    2014-01-01

    Motor vehicle crashes are a leading cause of injury and mortality for children. Mitigation of these injuries requires biofidelic anthropomorphic test devices (ATDs) to design and evaluate automotive safety systems. Effective countermeasures exist for frontal and near-side impacts but are limited for far-side impacts. Consequently, far-side impacts represent increased injury and mortality rates compared to frontal impacts. Thus, the objective of this study was to evaluate the biofidelity of the Hybrid III and Q-series pediatric ATDs in low-speed far-side impacts, with and without shoulder belt pretightening. Low-speed (2 g) far-side oblique (60°) and lateral (90°) sled tests were conducted using the Hybrid III and Q-series 6- and 10-year-old ATDs. ATDs were restrained by a lap and shoulder belt equipped with a precrash belt pretightener. Photoreflective targets were attached to the head, spine, shoulders, and sternum. ATDs were exposed to 8 low-speed sled tests: 2 oblique nontightened, 2 oblique pretightened, 2 lateral nontightened, 2 lateral pretightened. ATDs were compared with previously collected 9- to 11-year-old (n=10) volunteer data and newly collected 6- to 8-year-old volunteer data (n=7) tested with similar methods. Kinematic data were collected from a 3D target tracking system. Metrics of comparison included excursion, seat belt and seat pan reaction loads, belt-to-torso angle, and shoulder belt slip-out. The ATDs exhibited increased lateral excursion of the head top, C4, and T1 as well as increased downward excursion of the head top compared to the volunteers. Volunteers exhibited greater forward excursion than the ATDs in oblique nontightened impacts. These kinematics correspond to increased shoulder belt slip-out for the ATDs in oblique tests (ATDs=90%; volunteers=36%). Contrarily, similar shoulder belt slip-out was observed between ATDs and volunteers in lateral impacts (ATDs=80%; volunteers=78%). In pretightened impacts, the ATDs exhibited reduced lateral excursion and torso roll-out angle compared to the volunteers. In general, the ATDs overestimated lateral excursion in both impact directions, while underestimating forward excursion of the head and neck in oblique impacts compared to the pediatric volunteers. This was primarily due to pendulum-like lateral bending of the entire ATD torso compared to translation of the thorax relative to the abdomen prior to the lateral bending of the upper torso in the volunteers, likely due to the multisegmented spinal column in the volunteers. Additionally, the effect of belt pretightening on occupant kinematics was greater for the ATDs than the volunteers.

  6. Estimating white trunk rot in aspen stands

    Treesearch

    Alan C. Jones; Michael E. Ostry

    1998-01-01

    Advanced decay caused by Phellinus tremulae was estimated in 295 trembling aspen on 30 plots in 2 Minnesota counties using existing inventory guides, and then measured by felling and sectioning the trees. In standing trees, decay volume was underestimated by 38% compared to measured decay volume in felled trees. The most reliable external indicator...

  7. Intravesical markers for delineation of target volume during external focal irradiation of bladder carcinomas.

    PubMed

    Hulshof, Maarten C C M; van Andel, George; Bel, Arjen; Gangel, Pieter; van de Kamer, Jeroen B

    2007-07-01

    A clip forceps was developed which can insert markers at the border of a bladder tumour through a rigid cystoscope. This technique proved to be simple and safe and is of help for delineation of the target volume during CT simulation for focal boost irradiation of bladder cancer.

  8. Ad libitum fluid consumption via self- or external administration.

    PubMed

    Yeargin, Susan W; Finn, Megan E; Eberman, Lindsey E; Gage, Matthew J; McDermott, Brendon P; Niemann, Andrew

    2015-01-01

    During team athletic events, athletic trainers commonly provide fluids with water bottles. When a limited number of water bottles exist, various techniques are used to deliver fluids. To determine whether fluid delivered via water-bottle administration influenced fluid consumption and hydration status. Crossover study. Outdoor field (22.2°C ± 3.5°C). Nineteen participants (14 men, 5 women, age = 30 ± 10 years, height = 176 ± 8 cm, mass = 72.5 ± 10 kg) were recruited from the university and local running clubs. The independent variable was fluid delivery with 3 levels: self-administration with mouth-to-bottle direct contact (SA-DC), self-administration with no contact between mouth and bottle (SA-NC), and external administration with no contact between the mouth and the bottle (EA-NC). Participants warmed up for 10 minutes before completing 5 exercise stations, after which an ad libitum fluid break was given, for a total of 6 breaks. We measured the fluid variables of total volume consumed, total number of squirts, and average volume per squirt. Hydration status via urine osmolality and body-mass loss, and perceptual variables for thirst and fullness were recorded. We calculated repeated-measures analyses of variance to assess hydration status, fluid variables, and perceptual measures to analyze conditions across time. The total volume consumed for EA-NC was lower than for SA-DC (P = .001) and SA-NC (P = .001). The total number of squirts for SA-DC was lower than for SA-NC (P = .009). The average volume per squirt for EA-NC was lower than for SA-DC (P = .020) and SA-NC (P = .009). Participants arrived (601.0 ± 21.3 mOsm/L) and remained (622.3 ± 38.3 mOsm/L) hydrated, with no difference between conditions (P = .544); however, the EA-NC condition lost more body mass than did the SA-DC condition (P = .001). There was no main effect for condition on thirst (P = .147) or fullness (P = .475). External administration of fluid decreased total volume consumed via a decreased average volume per squirt. The SA-DC method requires fewer squirts within a specific time frame. Fluid breaks every 15 minutes resulted in maintenance of euhydration; however, loss of body mass was influenced by fluid administration. Athletic trainers should avoid external administration to promote positive hydration behaviors. When fluid is self-administered, individual bottles may be the best clinical practice because more volume can be consumed per squirt.

  9. 29 CFR 1915.152 - General requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) for the eyes, face, head, extremities, torso, and respiratory system, including protective clothing... section, to use PPE (exception: training in the use of personal fall arrest systems and positioning device systems training is covered in §§ 1915.159 and 1915.160). Each employee shall be trained to understand at...

  10. 29 CFR 1915.152 - General requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) for the eyes, face, head, extremities, torso, and respiratory system, including protective clothing... section, to use PPE (exception: training in the use of personal fall arrest systems and positioning device systems training is covered in §§ 1915.159 and 1915.160). Each employee shall be trained to understand at...

  11. 29 CFR 1915.152 - General requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) for the eyes, face, head, extremities, torso, and respiratory system, including protective clothing... section, to use PPE (exception: training in the use of personal fall arrest systems and positioning device systems training is covered in §§ 1915.159 and 1915.160). Each employee shall be trained to understand at...

  12. Analysis of Head Response to Torso Acceleration. Vol. II - Description of Data Retrieval, Analysis and Display Software.

    DOT National Transportation Integrated Search

    1987-11-01

    Performance requirements are developed which define the kinematic and kinetic response of the head for a seated subject exposed to frontal, lateral or oblique impact. Response is expressed in terms of variables which are readily measured in an anthro...

  13. Deriving the 12-Lead Electrocardiogram From Four Standard Leads Based on the Frank Torso Model

    DTIC Science & Technology

    2001-10-25

    System The University of Aizu, Fukushima Prefecture, Japan Abstract – This paper proposes a lead method and a processing means for monitoring the 12...Performing Organization Name(s) and Address(es) The University of Aizu Graduate School of Information System Fukushima Prefecture, Japan Performing

  14. 49 CFR 572.181 - General description.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... assembly Drawing number Head Assembly 175-1000 Neck Assembly Test/Cert 175-2000 Neck Bracket Including..., dated February 2008. (c) Weights of body segments (head, neck, upper and lower torso, arms and upper and... the convenience of the user, the added and revised text is set forth as follows: § 572.181 General...

  15. Matroshka-R Phantom experiment

    NASA Image and Video Library

    2006-12-01

    ISS014-E-09091 (December 2006) --- The European Matroshka-R Phantom experiment was photographed by an Expedition 14 crewmember in the Zvezda Service Module of the International Space Station. Matroshka, the name for the traditional Russian set of nestling dolls, is an antroph-amorphous model of a human torso designed for radiation studies.

  16. 49 CFR 572.194 - Shoulder.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 7 2013-10-01 2013-10-01 false Shoulder. 572.194 Section 572.194 Transportation..., Small Adult Female § 572.194 Shoulder. (a) The shoulder structure is part of the upper torso assembly shown in drawing 180-3000. For the shoulder impact test, the dummy is tested as a complete assembly...

  17. 49 CFR 572.194 - Shoulder.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 7 2012-10-01 2012-10-01 false Shoulder. 572.194 Section 572.194 Transportation..., Small Adult Female § 572.194 Shoulder. (a) The shoulder structure is part of the upper torso assembly shown in drawing 180-3000. For the shoulder impact test, the dummy is tested as a complete assembly...

  18. 49 CFR 572.194 - Shoulder.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 7 2014-10-01 2014-10-01 false Shoulder. 572.194 Section 572.194 Transportation..., Small Adult Female § 572.194 Shoulder. (a) The shoulder structure is part of the upper torso assembly shown in drawing 180-3000. For the shoulder impact test, the dummy is tested as a complete assembly...

  19. 49 CFR 572.194 - Shoulder.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 7 2011-10-01 2011-10-01 false Shoulder. 572.194 Section 572.194 Transportation..., Small Adult Female § 572.194 Shoulder. (a) The shoulder structure is part of the upper torso assembly shown in drawing 180-3000. For the shoulder impact test, the dummy is tested as a complete assembly...

  20. 19. NBS SUIT LAB. STORAGE SHELF WITH LIQUID COOLING VENTILATION ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    19. NBS SUIT LAB. STORAGE SHELF WITH LIQUID COOLING VENTILATION GARMENT (LCVG), SUIT GLOVES, WAIST INSERTS, UPPER AND LOWER ARMS (LEFT, FROM TOP TO BOTTOM), LOWER TORSO ASSEMBLIES (LTA) (MIDDLE RIGHT TO LOWER RIGHT). - Marshall Space Flight Center, Neutral Buoyancy Simulator Facility, Rideout Road, Huntsville, Madison County, AL

  1. 49 CFR 572.199 - Pelvis iliac.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 7 2013-10-01 2013-10-01 false Pelvis iliac. 572.199 Section 572.199... Test Dummy, Small Adult Female § 572.199 Pelvis iliac. (a) The iliac is part of the lower torso... the assembled dummy (drawing 180-0000). The dummy is equipped with a laterally oriented pelvis...

  2. 49 CFR 572.199 - Pelvis iliac.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 7 2011-10-01 2011-10-01 false Pelvis iliac. 572.199 Section 572.199... Dummy, Small Adult Female § 572.199 Pelvis iliac. (a) The iliac is part of the lower torso assembly... assembled dummy (drawing 180-0000). The dummy is equipped with a laterally oriented pelvis accelerometer as...

  3. 49 CFR 572.199 - Pelvis iliac.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 7 2014-10-01 2014-10-01 false Pelvis iliac. 572.199 Section 572.199... Test Dummy, Small Adult Female § 572.199 Pelvis iliac. (a) The iliac is part of the lower torso... the assembled dummy (drawing 180-0000). The dummy is equipped with a laterally oriented pelvis...

  4. 49 CFR 572.199 - Pelvis iliac.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 7 2010-10-01 2010-10-01 false Pelvis iliac. 572.199 Section 572.199... Dummy, Small Adult Female § 572.199 Pelvis iliac. (a) The iliac is part of the lower torso assembly... assembled dummy (drawing 180-0000). The dummy is equipped with a laterally oriented pelvis accelerometer as...

  5. 49 CFR 572.199 - Pelvis iliac.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 7 2012-10-01 2012-10-01 false Pelvis iliac. 572.199 Section 572.199... Dummy, Small Adult Female § 572.199 Pelvis iliac. (a) The iliac is part of the lower torso assembly... assembled dummy (drawing 180-0000). The dummy is equipped with a laterally oriented pelvis accelerometer as...

  6. En-Route Care Capability from Point of Injury Impacts Mortality after Severe Wartime Injury

    DTIC Science & Technology

    2013-02-01

    tranexamic acid .5,6 The greatest proportion of com- bat deaths, however, continue to occur in the prehospital setting, with noncompressible torso...Morrison JJ, DuBose JJ, Rasmussen TE, et al. Military Application of Tranex- amic acid in Trauma Emergency Resuscitation (MATTERs) Study. Arch Surg

  7. An arbitrary grid CFD algorithm for configuration aerodynamics analysis. Volume 1: Theory and validations

    NASA Technical Reports Server (NTRS)

    Baker, A. J.; Iannelli, G. S.; Manhardt, Paul D.; Orzechowski, J. A.

    1993-01-01

    This report documents the user input and output data requirements for the FEMNAS finite element Navier-Stokes code for real-gas simulations of external aerodynamics flowfields. This code was developed for the configuration aerodynamics branch of NASA ARC, under SBIR Phase 2 contract NAS2-124568 by Computational Mechanics Corporation (COMCO). This report is in two volumes. Volume 1 contains the theory for the derived finite element algorithm and describes the test cases used to validate the computer program described in the Volume 2 user guide.

  8. An arbitrary grid CFD algorithm for configuration aerodynamics analysis. Volume 2: FEMNAS user guide

    NASA Technical Reports Server (NTRS)

    Manhardt, Paul D.; Orzechowski, J. A.; Baker, A. J.

    1992-01-01

    This report documents the user input and output data requirements for the FEMNAS finite element Navier-Stokes code for real-gas simulations of external aerodynamics flowfields. This code was developed for the configuration aerodynamics branch of NASA ARC, under SBIR Phase 2 contract NAS2-124568 by Computational Mechanics Corporation (COMCO). This report is in two volumes. Volume 1 contains the theory for the derived finite element algorithm and describes the test cases used to validate the computer program described in the Volume 2 user guide.

  9. On the use of external burning to reduce aerospace vehicle transonic drag

    NASA Technical Reports Server (NTRS)

    Trefny, Charles J.

    1990-01-01

    The external combustion of hydrogen to reduce the transonic drag of aerospace vehicles is currently being investigated. A preliminary analysis based on a constant pressure control volume is discussed. Results indicate that the specific impulse of the external burning process rivals that of a turbojet and depends on the severity of the initial base drag as well as on the Mach flight number and the equivalence ratio. A test program was conducted to investigate hydrogen-air flame stability at the conditions of interest and to demonstrate drag reduction on a simple expansion ramp. Initial test results are presented and compared with the control-volume analysis. The expansion ramp surface pressure coefficient showed little variation with fuel pressure and altitude, in disagreement with the analysis. Flame stability results were encouraging and indicate that stable combustion is possible over an adequate range of conditions. Facility interference and chemical kinetics phenomena that make interpretation of subscale ground test data difficult are discussed.

  10. Importance of the mitral apparatus for left ventricular function: an experimental approach.

    PubMed

    Gams, E; Hagl, S; Schad, H; Heimisch, W; Mendler, N; Sebening, F

    1992-01-01

    In an experimental study of 31 anesthetized dogs the importance of the mitral apparatus for the left ventricular function was investigated. During extracorporeal circulation bileaflet mitral valve prostheses were implanted preserving the mitral subvalvular apparatus. Flexible wires were slung around the chordae tendineae and exteriorized through the left ventricular wall to cut the chordae by electrocautery from the outside when the heart was beating again. External and internal left ventricular dimensions were measured by sonomicrometry, left ventricular stroke volume by electromagnetic flowmeters around the ascending aorta, left ventricular end-diastolic volume by dye dilution technique, and left ventricular pressure by catheter tip manometers. Different preload levels were achieved by volume loading with blood transfusion before and after cutting the chordae tendineae. When the chordae had been divided peak systolic left ventricular pressure did not change. Heart rate only increased at the lowest left ventricular end-diastolic pressures of 3-4 mmHg, but remained unchanged at higher preload levels. Cardiac output decreased significantly up to -9% at left ventricular end-diastolic pressures of 5-10 mmHg, while left ventricular dp/dtmax showed a consistent reduction of up to -15% at any preload level. Significant reductions were also seen in systolic shortening in the left ventricular major axis (by external measurements -27%, by internal recording -43%). Left ventricular end-diastolic dimensions increased in the major axis by +2% when recorded externally, by +10% when measured internally. Systolic and diastolic changes in the minor axis were not consistent and different in the external and internal recordings.(ABSTRACT TRUNCATED AT 250 WORDS)

  11. Percentage of Cancer Volume in Biopsy Cores Is Prognostic for Prostate Cancer Death and Overall Survival in Patients Treated With Dose-Escalated External Beam Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vance, Sean M.; Stenmark, Matthew H.; Blas, Kevin

    2012-07-01

    Purpose: To investigate the prognostic utility of the percentage of cancer volume (PCV) in needle biopsy specimens for prostate cancer patients treated with dose-escalated external beam radiotherapy. Methods and Materials: The outcomes were analyzed for 599 men treated for localized prostate cancer with external beam radiotherapy to a minimal planning target volume dose of 75 Gy (range, 75-79.2). We assessed the effect of PCV and the pretreatment and treatment-related factors on the freedom from biochemical failure, freedom from metastasis, cause-specific survival, and overall survival. Results: The median number of biopsy cores was 7 (interquartile range, 6-12), median PCV was 10%more » (interquartile range, 2.5-25%), and median follow-up was 62 months. The PCV correlated with the National Comprehensive Cancer Network risk group and individual risk features, including T stage, prostate-specific antigen level, Gleason score, and percentage of positive biopsy cores. On log-rank analysis, the PCV stratified by quartile was prognostic for all endpoints, including overall survival. In addition, the PCV was a stronger prognostic factor than the percentage of positive biopsy cores when the two metrics were analyzed together. On multivariate analysis, the PCV predicted a worse outcome for all endpoints, including freedom from biochemical failure, (hazard ratio, 1.9; p = .0035), freedom from metastasis (hazard ratio, 1.7, p = .09), cause-specific survival (hazard ratio, 3.9, p = .014), and overall survival (hazard ratio, 1.8, p = .02). Conclusions: For patients treated with dose-escalated external beam radiotherapy, the volume of cancer in the biopsy specimen adds prognostic value for clinically relevant endpoints, particularly in intermediate- and high-risk patients. Although the PCV determination is more arduous than the percentage of positive biopsy cores, it provides superior risk stratification.« less

  12. Implementation of image-guided brachytherapy (IGBT) for patients with uterine cervix cancer: a tumor volume kinetics approach

    PubMed Central

    Mendez, Lucas Castro; Stuart, Silvia Radwanski; Guimarães, Roger Guilherme Rodrigues; Ramos, Clarissa Cerchi Angotti; de Paula, Lucas Assad; de Sales, Camila Pessoa; Chen, André Tsin Chih; Blasbalg, Roberto; Baroni, Ronaldo Hueb

    2016-01-01

    Purpose To evaluate tumor shrinking kinetics in order to implement image-guided brachytherapy (IGBT) for the treatment of patients with cervix cancer. Material and methods This study has prospectively evaluated tumor shrinking kinetics of thirteen patients with uterine cervix cancer treated with combined chemoradiation. Four high dose rate brachytherapy fractions were delivered during the course of pelvic external beam radiation therapy (EBRT). Magnetic resonance imaging (MRI) exams were acquired at diagnosis (D), first (B1), and third (B3) brachytherapy fractions. Target volumes (GTV and HR-CTV) were calculated by both the ellipsoid formula (VE) and MRI contouring (VC), which were defined by a consensus between at least two radiation oncologists and a pelvic expert radiologist. Results Most enrolled patients had squamous cell carcinoma and FIGO stage IIB disease, and initiated brachytherapy after the third week of pelvic external beam radiation. Gross tumor volume volume reduction from diagnostic MRI to B1 represented 61.9% and 75.2% of the initial volume, when measured by VE and VC, respectively. Only a modest volume reduction (15-20%) was observed from B1 to B3. Conclusions The most expressive tumor shrinking occurred in the first three weeks of oncological treatment and was in accordance with gynecological examination. These findings may help in IGBT implementation. PMID:27648083

  13. Space shuttle phase B extension, volume 1

    NASA Technical Reports Server (NTRS)

    1971-01-01

    In order to define a system which would significantly reduce payload delivery costs, activities were extended to modifications of the reusable space shuttle design concept. Considered were systems using orbiters with external propellant tanks and an interim expendable booster which allowed phased development of the usable orbiter and booster. Analyzed were: Merits of internal and external propellant tanks and the impact of external LH2 compared to L02 and LH2; impact of cargo bay size; impact abort; merit of expendable booster options; and merit of a phased development program. Studies showed that external L02/LH2 and the continued use of the J-2S engine on the orbiter reduced program cost and risk.

  14. SU-E-J-48: Development of An Abdominal Compression Device for Respiratory Correlated Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, T; Kang, S; Kim, D

    Purpose: The aim of this study is to develop the abdominal compression device which could control pressure level according to the abdominal respiratory motion and evaluate its feasibility. Methods: In this study, we focused on developing the abdominal compression device which could control pressure level at any point of time so the developed device is possible to use a variety of purpose (gating technique or respiratory training system) while maintaining the merit of the existing commercial device. The compression device (air pad form) was designed to be able to compress the front and side of abdomen and the pressure levelmore » of the abdomen is controlled by air flow. Pressure level of abdomen (air flow) was determined using correlation data between external abdominal motion and respiratory volume signal measured by spirometer. In order to verify the feasibility of the device, it was necessary to confirm the correlation between the abdominal respiratory motion and respiratory volume signal and cooperation with respiratory training system also checked. Results: In the previous study, we could find that the correlation coefficient ratio between diaphragm and respiratory volume signal measured by spirometer was 0.95. In this study, we confirmed the correlation between the respiratory volume signal and the external abdominal motion measured by belt-transducer (correlation coefficient ratio was 0.92) and used the correlated respiratory volume data as an abdominal pressure level. It was possible to control the pressure level with negligible time delay and respiratory volume data based guiding waveforms could be properly inserted into the respiratory training system. Conclusion: Through this feasibility study, we confirmed the correlation between the respiratory volume signal and the external abdominal motion. Also initial assessment of the device and its compatibility with the respiratory training system were verified. Further study on application in respiratory gated therapy and respiratory training system will be investigated. This work was supported by Radiation Technology R and D program (No. 2013M2A2A7043498)and Basic Atomic Energy Research Institute (BAERI)(No. NRF-2009-0078390) through the National Research Foundation of Korea funded by the Ministry of Science, ICT and Future Planning.« less

  15. Breakdown of String Perturbation Theory for Many External Particles.

    PubMed

    Ghosh, Sudip; Raju, Suvrat

    2017-03-31

    We consider massless string scattering amplitudes in a limit where the number of external particles becomes very large, while the energy of each particle remains small. Using the growth of the volume of the relevant moduli space, and by means of independent numerical evidence, we argue that string perturbation theory breaks down in this limit. We discuss some remarkable implications for the information paradox.

  16. Alternate space shuttle concepts study. Part 2: Technical summary. Volume 2: Orbiter definition

    NASA Technical Reports Server (NTRS)

    1971-01-01

    A study was conducted of a three-engined external hydrogen tank orbiter/heat sink booster utilizing 415 K sea level thrust engines. The results of the study, pertaining to the orbiter portion of the configuration, are presented. A complete summary of characteristics is given for the external tank configuration along with some comparative data for a conventional internal tank configuration.

  17. SU-E-J-44: A Novel Approach to Quantify Patient Setup and Target Motion for Real-Time Image-Guided Radiotherapy (IGRT)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, S; Charpentier, P; Sayler, E

    2015-06-15

    Purpose Isocenter shifts and rotations to correct patient setup errors and organ motion cannot remedy some shape changes of large targets. We are investigating new methods in quantification of target deformation for realtime IGRT of breast and chest wall cancer. Methods Ninety-five patients of breast or chest wall cancer were accrued in an IRB-approved clinical trial of IGRT using 3D surface images acquired at daily setup and beam-on time via an in-room camera. Shifts and rotations relating to the planned reference surface were determined using iterative-closest-point alignment. Local surface displacements and target deformation are measured via a ray-surface intersection andmore » principal component analysis (PCA) of external surface, respectively. Isocenter shift, upper-abdominal displacement, and vectors of the surface projected onto the two principal components, PC1 and PC2, were evaluated for sensitivity and accuracy in detection of target deformation. Setup errors for some deformed targets were estimated by superlatively registering target volume, inner surface, or external surface in weekly CBCT or these outlines on weekly EPI. Results Setup difference according to the inner-surface, external surface, or target volume could be 1.5 cm. Video surface-guided setup agreed with EPI results to within < 0.5 cm while CBCT results were sometimes (∼20%) different from that of EPI (>0.5 cm) due to target deformation for some large breasts and some chest walls undergoing deep-breath-hold irradiation. Square root of PC1 and PC2 is very sensitive to external surface deformation and irregular breathing. Conclusion PCA of external surfaces is quick and simple way to detect target deformation in IGRT of breast and chest wall cancer. Setup corrections based on the target volume, inner surface, and external surface could be significant different. Thus, checking of target shape changes is essential for accurate image-guided patient setup and motion tracking of large deformable targets. NIH grant for the first author as cionsultant and the last author as the PI.« less

  18. Temporal and geographical external validation study and extension of the Mayo Clinic prediction model to predict eGFR in the younger population of Swiss ADPKD patients.

    PubMed

    Girardat-Rotar, Laura; Braun, Julia; Puhan, Milo A; Abraham, Alison G; Serra, Andreas L

    2017-07-17

    Prediction models in autosomal dominant polycystic kidney disease (ADPKD) are useful in clinical settings to identify patients with greater risk of a rapid disease progression in whom a treatment may have more benefits than harms. Mayo Clinic investigators developed a risk prediction tool for ADPKD patients using a single kidney value. Our aim was to perform an independent geographical and temporal external validation as well as evaluate the potential for improving the predictive performance by including additional information on total kidney volume. We used data from the on-going Swiss ADPKD study from 2006 to 2016. The main analysis included a sample size of 214 patients with Typical ADPKD (Class 1). We evaluated the Mayo Clinic model performance calibration and discrimination in our external sample and assessed whether predictive performance could be improved through the addition of subsequent kidney volume measurements beyond the baseline assessment. The calibration of both versions of the Mayo Clinic prediction model using continuous Height adjusted total kidney volume (HtTKV) and using risk subclasses was good, with R 2 of 78% and 70%, respectively. Accuracy was also good with 91.5% and 88.7% of the predicted within 30% of the observed, respectively. Additional information regarding kidney volume did not substantially improve the model performance. The Mayo Clinic prediction models are generalizable to other clinical settings and provide an accurate tool based on available predictors to identify patients at high risk for rapid disease progression.

  19. NOTE Thyroid volume measurement in external beam radiotherapy patients using CT imaging: correlation with clinical and anthropometric characteristics

    NASA Astrophysics Data System (ADS)

    Veres, C.; Garsi, J. P.; Rubino, C.; Pouzoulet, F.; Bidault, F.; Chavaudra, J.; Bridier, A.; Ricard, M.; Ferreira, I.; Lefkopoulos, D.; de Vathaire, F.; Diallo, I.

    2010-11-01

    The aim of this study is to define criteria for accurate representation of the thyroid in human models used to represent external beam radiotherapy (EBRT) patients and evaluate the relationship between the volume of this organ and clinical and anthropometric characteristics. From CT images, we segmented the thyroid gland and calculated its volume for a population of 188 EBRT patients of both sexes, with ages ranging from 1 to 89 years. To evaluate uncertainties linked to measured volumes, experimental studies on the Livermore anthropomorphic phantom were performed. For our population of EBRT patients, we observed that in children, thyroid volume increased rapidly with age, from about 3 cm3 at 2 years to about 16 cm3 at 20. In adults, the mean thyroid gland volume was 23.5 ± 9 cm3 for males and 17.5 ± 8 cm3 for females. According to anthropometric parameters, the best fit for children was obtained by modeling the log of thyroid volume as a linear function of body surface area (BSA) (p < 0.0001) and age (p = 0.04) and for adults, as a linear function of BSA (p < 0.0001) and gender (p = 0.01). This work enabled us to demonstrate that BSA was the best indicator of thyroid volume for both males and females. These results should be taken into account when modeling the volume of the thyroid in human models used to represent EBRT patients for dosimetry in retrospective studies of the relationship between the estimated dose to the thyroid and long-term follow-up data on EBRT patients.

  20. Accuracy and Reproducibility of Adipose Tissue Measurements in Young Infants by Whole Body Magnetic Resonance Imaging

    PubMed Central

    Bauer, Jan Stefan; Noël, Peter Benjamin; Vollhardt, Christiane; Much, Daniela; Degirmenci, Saliha; Brunner, Stefanie; Rummeny, Ernst Josef; Hauner, Hans

    2015-01-01

    Purpose MR might be well suited to obtain reproducible and accurate measures of fat tissues in infants. This study evaluates MR-measurements of adipose tissue in young infants in vitro and in vivo. Material and Methods MR images of ten phantoms simulating subcutaneous fat of an infant’s torso were obtained using a 1.5T MR scanner with and without simulated breathing. Scans consisted of a cartesian water-suppression turbo spin echo (wsTSE) sequence, and a PROPELLER wsTSE sequence. Fat volume was quantified directly and by MR imaging using k-means clustering and threshold-based segmentation procedures to calculate accuracy in vitro. Whole body MR was obtained in sleeping young infants (average age 67±30 days). This study was approved by the local review board. All parents gave written informed consent. To obtain reproducibility in vivo, cartesian and PROPELLER wsTSE sequences were repeated in seven and four young infants, respectively. Overall, 21 repetitions were performed for the cartesian sequence and 13 repetitions for the PROPELLER sequence. Results In vitro accuracy errors depended on the chosen segmentation procedure, ranging from 5.4% to 76%, while the sequence showed no significant influence. Artificial breathing increased the minimal accuracy error to 9.1%. In vivo reproducibility errors for total fat volume of the sleeping infants ranged from 2.6% to 3.4%. Neither segmentation nor sequence significantly influenced reproducibility. Conclusion With both cartesian and PROPELLER sequences an accurate and reproducible measure of body fat was achieved. Adequate segmentation was mandatory for high accuracy. PMID:25706876

  1. Local Multi-Channel RF Surface Coil versus Body RF Coil Transmission for Cardiac Magnetic Resonance at 3 Tesla: Which Configuration Is Winning the Game?

    PubMed

    Weinberger, Oliver; Winter, Lukas; Dieringer, Matthias A; Els, Antje; Oezerdem, Celal; Rieger, Jan; Kuehne, Andre; Cassara, Antonino M; Pfeiffer, Harald; Wetterling, Friedrich; Niendorf, Thoralf

    2016-01-01

    The purpose of this study was to demonstrate the feasibility and efficiency of cardiac MR at 3 Tesla using local four-channel RF coil transmission and benchmark it against large volume body RF coil excitation. Electromagnetic field simulations are conducted to detail RF power deposition, transmission field uniformity and efficiency for local and body RF coil transmission. For both excitation regimes transmission field maps are acquired in a human torso phantom. For each transmission regime flip angle distributions and blood-myocardium contrast are examined in a volunteer study of 12 subjects. The feasibility of the local transceiver RF coil array for cardiac chamber quantification at 3 Tesla is demonstrated. Our simulations and experiments demonstrate that cardiac MR at 3 Tesla using four-channel surface RF coil transmission is competitive versus current clinical CMR practice of large volume body RF coil transmission. The efficiency advantage of the 4TX/4RX setup facilitates shorter repetition times governed by local SAR limits versus body RF coil transmission at whole-body SAR limit. No statistically significant difference was found for cardiac chamber quantification derived with body RF coil versus four-channel surface RF coil transmission. Our simulation also show that the body RF coil exceeds local SAR limits by a factor of ~2 when driven at maximum applicable input power to reach the whole-body SAR limit. Pursuing local surface RF coil arrays for transmission in cardiac MR is a conceptually appealing alternative to body RF coil transmission, especially for patients with implants.

  2. Accuracy and reproducibility of adipose tissue measurements in young infants by whole body magnetic resonance imaging.

    PubMed

    Bauer, Jan Stefan; Noël, Peter Benjamin; Vollhardt, Christiane; Much, Daniela; Degirmenci, Saliha; Brunner, Stefanie; Rummeny, Ernst Josef; Hauner, Hans

    2015-01-01

    MR might be well suited to obtain reproducible and accurate measures of fat tissues in infants. This study evaluates MR-measurements of adipose tissue in young infants in vitro and in vivo. MR images of ten phantoms simulating subcutaneous fat of an infant's torso were obtained using a 1.5T MR scanner with and without simulated breathing. Scans consisted of a cartesian water-suppression turbo spin echo (wsTSE) sequence, and a PROPELLER wsTSE sequence. Fat volume was quantified directly and by MR imaging using k-means clustering and threshold-based segmentation procedures to calculate accuracy in vitro. Whole body MR was obtained in sleeping young infants (average age 67±30 days). This study was approved by the local review board. All parents gave written informed consent. To obtain reproducibility in vivo, cartesian and PROPELLER wsTSE sequences were repeated in seven and four young infants, respectively. Overall, 21 repetitions were performed for the cartesian sequence and 13 repetitions for the PROPELLER sequence. In vitro accuracy errors depended on the chosen segmentation procedure, ranging from 5.4% to 76%, while the sequence showed no significant influence. Artificial breathing increased the minimal accuracy error to 9.1%. In vivo reproducibility errors for total fat volume of the sleeping infants ranged from 2.6% to 3.4%. Neither segmentation nor sequence significantly influenced reproducibility. With both cartesian and PROPELLER sequences an accurate and reproducible measure of body fat was achieved. Adequate segmentation was mandatory for high accuracy.

  3. 14 CFR 25.562 - Emergency landing dynamic conditions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ...— (1) Proper use is made of seats, safety belts, and shoulder harnesses provided for in the design; and... likelihood of the upper torso restraint system (where installed) moving off the occupant's shoulder, and with... shoulder during the impact. (4) The lap safety belt must remain on the occupant's pelvis during the impact...

  4. 14 CFR 25.562 - Emergency landing dynamic conditions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ...— (1) Proper use is made of seats, safety belts, and shoulder harnesses provided for in the design; and... likelihood of the upper torso restraint system (where installed) moving off the occupant's shoulder, and with... shoulder during the impact. (4) The lap safety belt must remain on the occupant's pelvis during the impact...

  5. 14 CFR 25.562 - Emergency landing dynamic conditions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ...— (1) Proper use is made of seats, safety belts, and shoulder harnesses provided for in the design; and... likelihood of the upper torso restraint system (where installed) moving off the occupant's shoulder, and with... shoulder during the impact. (4) The lap safety belt must remain on the occupant's pelvis during the impact...

  6. 14 CFR 25.562 - Emergency landing dynamic conditions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ...— (1) Proper use is made of seats, safety belts, and shoulder harnesses provided for in the design; and... likelihood of the upper torso restraint system (where installed) moving off the occupant's shoulder, and with... shoulder during the impact. (4) The lap safety belt must remain on the occupant's pelvis during the impact...

  7. 14 CFR 27.785 - Seats, berths, litters, safety belts, and harnesses.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ....561(b) and dynamic conditions specified in § 27.562. (b) Each occupant must be protected from serious... combination with the safety belt, constitutes a torso restraint system as described in TSO-C114. (c) Each... weight of at least 170 pounds, considering the dimensional characteristics of the restraint system...

  8. 14 CFR 29.785 - Seats, berths, litters, safety belts, and harnesses.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... dynamic conditions specified in § 29.562. (b) Each occupant must be protected from serious head injury by... combination with the safety belt, constitutes a torso restraint system as described in TSO-C114. (c) Each... weight of at least 170 pounds, considering the dimensional characteristics of the restraint system...

  9. 49 CFR 572.196 - Thorax without arm.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 7 2012-10-01 2012-10-01 false Thorax without arm. 572.196 Section 572.196... Dummy, Small Adult Female § 572.196 Thorax without arm. (a) The thorax is part of the upper torso... (drawing 180-0000) with the arm (180-6000) on the impacted side removed. The dummy's thorax is equipped...

  10. 49 CFR 572.196 - Thorax without arm.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 7 2014-10-01 2014-10-01 false Thorax without arm. 572.196 Section 572.196... Test Dummy, Small Adult Female § 572.196 Thorax without arm. (a) The thorax is part of the upper torso... (drawing 180-0000) with the arm (180-6000) on the impacted side removed. The dummy's thorax is equipped...

  11. 49 CFR 572.196 - Thorax without arm.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 7 2011-10-01 2011-10-01 false Thorax without arm. 572.196 Section 572.196... Dummy, Small Adult Female § 572.196 Thorax without arm. (a) The thorax is part of the upper torso... (drawing 180-0000) with the arm (180-6000) on the impacted side removed. The dummy's thorax is equipped...

  12. 49 CFR 572.196 - Thorax without arm.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 7 2013-10-01 2013-10-01 false Thorax without arm. 572.196 Section 572.196... Test Dummy, Small Adult Female § 572.196 Thorax without arm. (a) The thorax is part of the upper torso... (drawing 180-0000) with the arm (180-6000) on the impacted side removed. The dummy's thorax is equipped...

  13. Spacsuit donning and doffing in zero-g training for Don Peterson STS-6

    NASA Technical Reports Server (NTRS)

    1982-01-01

    Spacsuit donning and doffing in zero-g training for Don Peterson of the STS-6 crew. The training is being held aboard the KC-135 to simulate weightlessness. He is being assisted to don the lower torso of the extravehicular mobility unit (EMU) by an ILC technician.

  14. 49 CFR 572.188 - Pelvis.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 7 2012-10-01 2012-10-01 false Pelvis. 572.188 Section 572.188 Transportation... Percentile Adult Male § 572.188 Pelvis. (a) The pelvis (175-6000) is part of the torso assembly shown in drawing 175-0000. The pelvis is equipped with a pubic symphysis load sensor in conformance with § 572.189...

  15. 49 CFR 572.188 - Pelvis.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 7 2014-10-01 2014-10-01 false Pelvis. 572.188 Section 572.188 Transportation..., 50th Percentile Adult Male § 572.188 Pelvis. (a) The pelvis (175-6000) is part of the torso assembly shown in drawing 175-0000. The pelvis is equipped with a pubic symphysis load sensor in conformance with...

  16. 49 CFR 572.188 - Pelvis.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 7 2010-10-01 2010-10-01 false Pelvis. 572.188 Section 572.188 Transportation... Percentile Adult Male § 572.188 Pelvis. (a) The pelvis (175-6000) is part of the torso assembly shown in drawing 175-0000. The pelvis is equipped with a pubic symphysis load sensor in conformance with § 572.189...

  17. 49 CFR 572.188 - Pelvis.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 7 2013-10-01 2013-10-01 false Pelvis. 572.188 Section 572.188 Transportation..., 50th Percentile Adult Male § 572.188 Pelvis. (a) The pelvis (175-6000) is part of the torso assembly shown in drawing 175-0000. The pelvis is equipped with a pubic symphysis load sensor in conformance with...

  18. 49 CFR 572.188 - Pelvis.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 7 2011-10-01 2011-10-01 false Pelvis. 572.188 Section 572.188 Transportation... Percentile Adult Male § 572.188 Pelvis. (a) The pelvis (175-6000) is part of the torso assembly shown in drawing 175-0000. The pelvis is equipped with a pubic symphysis load sensor in conformance with § 572.189...

  19. 49 CFR 572.85 - Lumbar spine flexure.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...) of this section, the lumbar spine assembly shall flex by an amount that permits the thoracic spine to... to the thoracic spine box. Apply the force at any torso deflection rate between 0.5 and 1.5 degrees... 49 Transportation 7 2011-10-01 2011-10-01 false Lumbar spine flexure. 572.85 Section 572.85...

  20. Selective Nonoperative Management of Penetrating Torso Injury From Combat Fragmentation Wounds

    DTIC Science & Technology

    2008-02-01

    outlines the paradigm of care: “Penetrating inju- ries below the nipples , above the symphysis pubis, and between the posterior axillary lines must be...abdo- men and were hemodynamically stable and without abdom- inal pain or tenderness. CT scan of some of these casualties revealed fragments in the lumen

  1. Comparison of upper extremity kinematics in children with spastic diplegic cerebral palsy using anterior and posterior walkers.

    PubMed

    Strifling, Kelly M B; Lu, Na; Wang, Mei; Cao, Kevin; Ackman, Jeffrey D; Klein, John P; Schwab, Jeffrey P; Harris, Gerald F

    2008-10-01

    This prospective study analyzes the upper extremity kinematics of 10 children with spastic diplegic cerebral palsy using anterior and posterior walkers. Although both types of walkers are commonly prescribed by clinicians, no quantitative data comparing the two in regards to upper extremity motion has been published. The study methodology included testing of each subject with both types of walkers in a motion analysis laboratory after an acclimation period of at least 1 month. Overall results showed that statistically, both walkers are relatively similar. With both anterior and posterior walkers, the shoulders were extended, elbows flexed, and wrists extended. Energy expenditure, walking speed and stride length was also similar with both walker types. Several differences were also noted although not statistically significant. Anterior torso tilt was reduced with the posterior walker and shoulder extension and elbow flexion were increased. Outcomes analysis indicated that differences in upper extremity torso and joint motion were not dependent on spasticity or hand dominance. These findings may help to build an understanding of upper extremity motion in walker-assisted gait and potentially to improve walker prescription.

  2. Evaluation of corrective reconstruction methods using a 3D cardiac-torso phantom and bull's-eye plots

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhao, X.D.; Tsui, B.M.W.; Gregoriou, G.K.

    The goal of the investigation was to study the effectiveness of the corrective reconstruction methods in cardiac SPECT using a realistic phantom and to qualitatively and quantitatively evaluate the reconstructed images using bull's-eye plots. A 3D mathematical phantom which realistically models the anatomical structures of the cardiac-torso region of patients was used. The phantom allows simulation of both the attenuation distribution and the uptake of radiopharmaceuticals in different organs. Also, the phantom can be easily modified to simulate different genders and variations in patient anatomy. Two-dimensional projection data were generated from the phantom and included the effects of attenuation andmore » detector response blurring. The reconstruction methods used in the study included the conventional filtered backprojection (FBP) with no attenuation compensation, and the first-order Chang algorithm, an iterative filtered backprojection algorithm (IFBP), the weighted least square conjugate gradient algorithm and the ML-EM algorithm with non-uniform attenuation compensation. The transaxial reconstructed images were rearranged into short-axis slices from which bull's-eye plots of the count density distribution in the myocardium were generated.« less

  3. Refinement of Optimal Work Envelope for Extra-Vehicular Activity (EVA) Suit Operations

    NASA Technical Reports Server (NTRS)

    Jaramillo, Marcos A.; Angermiller, Bonnie L.; Morency, Richard M.; Rajululu, Sudhakar L.

    2008-01-01

    The purpose of the Extravehicular Mobility Unit (EMU) Work Envelope study is to determine and revise the work envelope defined in NSTS 07700 "System Description and Design Data - Extravehicular Activities" [1], arising from an action item as a result of the Shoulder Injury Tiger Team findings. The aim of this study is to determine a common work envelope that will encompass a majority of the crew population while minimizing the possibility of shoulder and upper arm injuries. There will be approximately two phases of testing: arm sweep analysis to be performed in the Anthropometry and Biomechanics Facility (ABF), and torso lean testing to be performed on the Precision Air Bearing Facility (PABF). NSTS 07700 defines the preferred work envelope arm reach in terms of maximum reach, and defines the preferred work envelope torso flexibility of a crewmember to be a net 45 degree backwards lean [1]. This test served two functions: to investigate the validity of the standard discussed in NSTS 07700, and to provide recommendations to update this standard if necessary.

  4. Investigation of the use of thermography for research and clinical applications in pregnant women

    NASA Astrophysics Data System (ADS)

    Topalidou, Anastasia; Downe, Soo

    2016-03-01

    Background: The possibility of using thermal imaging, as a non-invasive method, in medicine may provide potential ability of advanced imaging. Objective: The conduction of a preliminary study in healthy non-pregnant females in order to investigate the imaging ability of thermography and its implementation; and to determine hot and cold areas in order to create a "map" of temperature distribution of the abdomen and the torso. Methods: Participants were 18-45 years old non-pregnant women (n = 10), who were measured at 4 different distances. Two thermal imaging cameras and their corresponding software were used to measure abdomen, low back, left and right side of the torso. Results: There were no statistically significant differences in the mean values of the exported temperatures according the distance and the angle between the camera and the subject. The inferior part of the rectus abdominis muscle recorded the coldest zone and the umbilicus appeared as the most prominent hot spot. Conclusions: Thermography shows to be a potential non-invasive technique offering new options in the evaluation of pregnant and laboring women.

  5. Measurement of absorbed dose during the phantom torso experiment on the International Space Station

    NASA Astrophysics Data System (ADS)

    Semones, E.; Gibbons, F.; Golightly, M.; Weyland, M.; Johnson, A.; Smith, G.; Shelfer, T.; Zapp, N.

    The Phantom Torso Experiment (PTE) was flown on the International Space Station (ISS) during Increment 2 (April-August 2001). The experiment was located in the US Lab module Human Research Facility (HRF) rack. The objective of the passive dosimetry portion of the experiment was to measure spatial distributions of absorbed dose in the 34, 1 inch sections of a modified RandoTM phantom. In each section of the phantom, thermoluminescent detectors (TLDs) were placed at various locations (depths) to provide the spatial measurement. TLDs were also located at several radiosensitive organ locations (brain, thyroid, heart/lung, stomach and colon) and two locations on the surface (skin). Active silicon detectors were also placed at these organ locations to provide time resolved results of the absorbed dose rates. Using these detectors, it is possible to separate the trapped and galactic cosmic ray components of the absorbed dose. The TLD results of the spatial and organ dose measurements will be presented and comparisons of the TLD and silicon detector organ absorbed doses will be made.

  6. Automated torso organ segmentation from 3D CT images using structured perceptron and dual decomposition

    NASA Astrophysics Data System (ADS)

    Nimura, Yukitaka; Hayashi, Yuichiro; Kitasaka, Takayuki; Mori, Kensaku

    2015-03-01

    This paper presents a method for torso organ segmentation from abdominal CT images using structured perceptron and dual decomposition. A lot of methods have been proposed to enable automated extraction of organ regions from volumetric medical images. However, it is necessary to adjust empirical parameters of them to obtain precise organ regions. This paper proposes an organ segmentation method using structured output learning. Our method utilizes a graphical model and binary features which represent the relationship between voxel intensities and organ labels. Also we optimize the weights of the graphical model by structured perceptron and estimate the best organ label for a given image by dynamic programming and dual decomposition. The experimental result revealed that the proposed method can extract organ regions automatically using structured output learning. The error of organ label estimation was 4.4%. The DICE coefficients of left lung, right lung, heart, liver, spleen, pancreas, left kidney, right kidney, and gallbladder were 0.91, 0.95, 0.77, 0.81, 0.74, 0.08, 0.83, 0.84, and 0.03, respectively.

  7. Role of UV light in photodamage, skin aging, and skin cancer: importance of photoprotection.

    PubMed

    Gonzaga, Evelyn R

    2009-01-01

    Solar, and particularly UV, radiation causes molecular and cellular damage with resultant histopathologic and clinical degenerative changes, leading in turn to photosensitivity, photo-aging, and skin cancer. While our bodies have some natural UV defenses, additional protection from the sun is essential, including sun avoidance, physical protection, and sunscreen use. Sun avoidance includes limiting exposure during peak UV times (10am-4pm), avoiding UV-reflective surfaces such as sand, snow and water, and eliminating photosensitizing drugs. Physical protection includes wearing photoprotective clothing such as a broad-brimmed hat and long sleeves and use of UV-blocking films on windows. Sunscreen containing avobenzone, titanium dioxide, zinc oxide or encamsule should be used daily and frequently reapplied. To guard against the UVB spectrum, zinc oxide and titanium dioxide are particularly recommended. Sunscreen is generally under-applied at only 25% of the recommended dose, seriously compromising photoprotection. Dosage guidelines recommend using more than half a teaspoon each on head and neck area and each arm, and more than a teaspoon each on anterior torso, posterior torso, and each leg (approximately 2 mg/cm(2)).

  8. Scripting human animations in a virtual environment

    NASA Technical Reports Server (NTRS)

    Goldsby, Michael E.; Pandya, Abhilash K.; Maida, James C.

    1994-01-01

    The current deficiencies of virtual environment (VE) are well known: annoying lag time in drawing the current view, drastically simplified environments to reduce that time lag, low resolution and narrow field of view. Animation scripting is an application of VE technology which can be carried out successfully despite these deficiencies. The final product is a smoothly moving high resolution animation displaying detailed models. In this system, the user is represented by a human computer model with the same body proportions. Using magnetic tracking, the motions of the model's upper torso, head and arms are controlled by the user's movements (18 degrees of freedom). The model's lower torso and global position and orientation are controlled by a spaceball and keypad (12 degrees of freedom). Using this system human motion scripts can be extracted from the user's movements while immersed in a simplified virtual environment. Recorded data is used to define key frames; motion is interpolated between them and post processing adds a more detailed environment. The result is a considerable savings in time and a much more natural-looking movement of a human figure in a smooth and seamless animation.

  9. Development and evaluation of statistical shape modeling for principal inner organs on torso CT images.

    PubMed

    Zhou, Xiangrong; Xu, Rui; Hara, Takeshi; Hirano, Yasushi; Yokoyama, Ryujiro; Kanematsu, Masayuki; Hoshi, Hiroaki; Kido, Shoji; Fujita, Hiroshi

    2014-07-01

    The shapes of the inner organs are important information for medical image analysis. Statistical shape modeling provides a way of quantifying and measuring shape variations of the inner organs in different patients. In this study, we developed a universal scheme that can be used for building the statistical shape models for different inner organs efficiently. This scheme combines the traditional point distribution modeling with a group-wise optimization method based on a measure called minimum description length to provide a practical means for 3D organ shape modeling. In experiments, the proposed scheme was applied to the building of five statistical shape models for hearts, livers, spleens, and right and left kidneys by use of 50 cases of 3D torso CT images. The performance of these models was evaluated by three measures: model compactness, model generalization, and model specificity. The experimental results showed that the constructed shape models have good "compactness" and satisfied the "generalization" performance for different organ shape representations; however, the "specificity" of these models should be improved in the future.

  10. Scary gas: pathways in the axial body for soft tissue gas dissection (part I).

    PubMed

    Sandstrom, Claire K; Osman, Sherif F; Linnau, Ken F

    2017-10-01

    Gas is often encountered in abnormal locations in the torso, including within soft tissue compartments, vessels, and bones. The clinical significance of this gas ranges from incidental, benign, and self-limited to aggressive infection requiring immediate surgery. As a result of fascial interconnectivity and pressure differences between compartments, gas can dissect distant from its source. Gas can easily dissect between spaces of the extrapleural thorax, subperitoneal abdomen, deep cervical spaces, and subcutaneous tissues. The pleural and peritoneal cavities are normally isolated but may communicate with the other spaces in select situations. Dissection of gas may cause confusion as to its origin, potentially delaying treatment or prompting unnecessary and/or distracting workup and therapies. The radiologist might be the first to suggest and identify a remote source of dissecting gas when the clinical manifestation alone might be misleading. The purpose of this paper, the first in a three-part series on soft tissue gas, is to explore the various pathways by which gas dissects through the superficial and deep compartments of the torso.

  11. Measuring Intracranial Pressure And Volume Noninvasively

    NASA Technical Reports Server (NTRS)

    Cantrell, John H.; Yost, William T.

    1994-01-01

    Ultrasonic technique eliminates need to drill into brain cavity. Intracranial dynamics instrument probes cranium ultrasonically to obtain data for determination of intracranial pressure (ICP) and pressure-volume index (PVI). Instrument determines sensitivity of skull to changes in pressure and by use of mechanical device to exert external calibrated pressure on skull. By monitoring volume of blood flowing into jugular vein, one determines change of volume of blood in cranial system. By measuring response of skull to increasing pressure (where pressure increased by tilting patient known amount) and by using cranial blood pressure, one determines intial pressure in cerebrospinal fluid. Once PVI determined, ICP determined.

  12. Occupant kinematics and estimated effectiveness of side airbags in pole side impacts using a human FE model with internal organs.

    PubMed

    Hayashi, Shigeki; Yasuki, Tsuyoshi; Kitagawa, Yuichi

    2008-11-01

    When a car collides against a pole-like obstacle, the deformation pattern of the vehicle body-side tends to extend to its upper region. A possible consequence is an increase of loading to the occupant thorax. Many studies have been conducted to understand human thoracic responses to lateral loading, and injury criteria have been developed based on the results. However, injury mechanisms, especially those of internal organs, are not well understood. A human body FE model was used in this study to simulate occupant kinematics in a pole side impact. Internal organ parts were introduced into the torso model, including their geometric features, material properties and connections with other tissues. The mechanical responses of the model were validated against PMHS data in the literature. Although injury criterion for each organ has not been established, pressure level and its changes can be estimated from the organ models. Finite element simulations were conducted assuming a case where a passenger vehicle collides against a pole at 29km/h. Occupant kinematics, force-deformation responses and pressure levels were compared between cases with and without side airbag deployment. The results indicated that strain to the ribs and pressure to the organs was smaller with side airbag deployment. The side airbag widened the contact area at the torso, helping to distribute the force to the shoulder, arm and chest. Such distributed force helped generate relatively smaller deformation in the ribs. Furthermore, the side airbag deployment helped restrict the spine displacement. The smaller displacement contributed to lowering the magnitude of contact force between the torso and the door. The study also examined the correlations between the pressure levels in the internal organs, rib deflection, and V*C of chest. The study found that the V*C(t) peak appeared to be synchronized with the organ pressure peak, suggesting that the pressure level of the internal organs could be one possible indicator to estimate their injury risk.

  13. Preliminary Testing of a Pressurized Space Suit and Candidate Fabrics Under Simulated Mars Dust Storm and Dust Devil Conditions

    NASA Technical Reports Server (NTRS)

    Gaier, James R.; deLeon, Pablo G.; Lee, Pascal; McCue, Terry R.; Hodgson, Edward W.; Thrasher, Jeff

    2010-01-01

    In August 2009 YAP Films (Toronto) received permission from all entities involved to create a documentary film illustrating what it might be like to be on the surface of Mars in a space suit during a dust storm or in a dust devil. The science consultants on this project utilized this opportunity to collect data which could be helpful to assess the durability of current space suit construction to the Martian environment. The NDX?1 prototype planetary space suit developed at the University of North Dakota was used in this study. The suit features a hard upper torso garment, and a soft lower torso and boots assembly. On top of that, a nylon-cotton outer layer is used to protect the suit from dust. Unmanned tests were carried out in the Martian Surface Wind Tunnel (MARSWIT) at the NASA Ames Research Center, with the suit pressurized to 10 kPa gauge. These tests blasted the space suit upper torso and helmet, and a collection of nine candidate outer layer fabrics, with wind-borne simulant for five different 10 minute tests under both terrestrial and Martian surface pressures. The infiltration of the dust through the outer fabric of the space suit was photographically documented. The nine fabric samples were analyzed under light and electron microscopes for abrasion damage. Manned tests were carried out at Showbiz Studios (Van Nuys, CA) with the pressure maintained at 20?2 kPa gauge. A large fan-created vortex lifted Martian dust simulant (Fullers Earth or JSC Mars?1) off of the floor, and one of the authors (Lee) wearing the NDX?1 space suit walked through it to judge both subjectively and objectively how the suit performed under these conditions. Both the procedures to scale the tests to Martian conditions and the results of the infiltration and abrasion studies will be discussed.

  14. A New Algorithm to Diagnose Atrial Ectopic Origin from Multi Lead ECG Systems - Insights from 3D Virtual Human Atria and Torso

    PubMed Central

    Alday, Erick A. Perez; Colman, Michael A.; Langley, Philip; Butters, Timothy D.; Higham, Jonathan; Workman, Antony J.; Hancox, Jules C.; Zhang, Henggui

    2015-01-01

    Rapid atrial arrhythmias such as atrial fibrillation (AF) predispose to ventricular arrhythmias, sudden cardiac death and stroke. Identifying the origin of atrial ectopic activity from the electrocardiogram (ECG) can help to diagnose the early onset of AF in a cost-effective manner. The complex and rapid atrial electrical activity during AF makes it difficult to obtain detailed information on atrial activation using the standard 12-lead ECG alone. Compared to conventional 12-lead ECG, more detailed ECG lead configurations may provide further information about spatio-temporal dynamics of the body surface potential (BSP) during atrial excitation. We apply a recently developed 3D human atrial model to simulate electrical activity during normal sinus rhythm and ectopic pacing. The atrial model is placed into a newly developed torso model which considers the presence of the lungs, liver and spinal cord. A boundary element method is used to compute the BSP resulting from atrial excitation. Elements of the torso mesh corresponding to the locations of the placement of the electrodes in the standard 12-lead and a more detailed 64-lead ECG configuration were selected. The ectopic focal activity was simulated at various origins across all the different regions of the atria. Simulated BSP maps during normal atrial excitation (i.e. sinoatrial node excitation) were compared to those observed experimentally (obtained from the 64-lead ECG system), showing a strong agreement between the evolution in time of the simulated and experimental data in the P-wave morphology of the ECG and dipole evolution. An algorithm to obtain the location of the stimulus from a 64-lead ECG system was developed. The algorithm presented had a success rate of 93%, meaning that it correctly identified the origin of atrial focus in 75/80 simulations, and involved a general approach relevant to any multi-lead ECG system. This represents a significant improvement over previously developed algorithms. PMID:25611350

  15. Preliminary Testing of a Pressurized Space Suit and Candidate Fabrics Under Simulated Mars Dust Storm and Dust Devil Conditions

    NASA Technical Reports Server (NTRS)

    Gaier, James R.; deLeon, Pablo G.; Lee, Pascal; McCue, Terry R.; Hodgson, Edward W.; Thrasher, Jeff

    2010-01-01

    In August 2009 YAP Films (Toronto) received permission from all entities involved to create a documentary film illustrating what it might be like to be on the surface of Mars in a space suit during a dust storm or in a dust devil. The science consultants on this project utilized this opportunity to collect data which could be helpful to assess the durability of current space suit construction to the Martian environment. The NDX-1 prototype planetary space suit developed at the University of North Dakota was used in this study. The suit features a hard upper torso garment, and a soft lower torso and boots assembly. On top of that, a nylon-cotton outer layer is used to protect the suit from dust. Unmanned tests were carried out in the Martian Surface Wind Tunnel (MARSWIT) at the NASA Ames Research Center, with the suit pressurized to 10 kPa gauge. These tests blasted the space suit upper torso and helmet, and a collection of nine candidate outer layer fabrics, with wind-borne simulant for five different 10 min tests under both terrestrial and Martian surface pressures. The infiltration of the dust through the outer fabric of the space suit was photographically documented. The nine fabric samples were analyzed under light and electron microscopes for abrasion damage. Manned tests were carried out at Showbiz Studios (Van Nuys, California) with the pressure maintained at 20 2 kPa gauge. A large fan-created vortex lifted Martian dust simulant (Fullers Earth or JSC Mars-1) off of the floor, and one of the authors (Lee) wearing the NDX-1 space suit walked through it to judge both subjectively and objectively how the suit performed under these conditions. Both the procedures to scale the tests to Martian conditions and the results of the infiltration and abrasion studies will be discussed.

  16. Personal cooling with phase change materials to improve thermal comfort from a heat wave perspective.

    PubMed

    Gao, C; Kuklane, K; Wang, F; Holmér, I

    2012-12-01

    The impact of heat waves arising from climate change on human health is predicted to be profound. It is important to be prepared with various preventive measures for such impacts on society. The objective of this study was to investigate whether personal cooling with phase change materials (PCM) could improve thermal comfort in simulated office work at 34°C. Cooling vests with PCM were measured on a thermal manikin before studies on human subjects. Eight male subjects participated in the study in a climatic chamber (T(a) = 34°C, RH = 60%, and ν(a) = 0.4 m/s). Results showed that the cooling effect on the manikin torso was 29.1 W/m(2) in the isothermal condition. The results on the manikin using a constant heating power mode reflect directly the local cooling effect on subjects. The results on the subjects showed that the torso skin temperature decreased by about 2-3°C and remained at 33.3°C. Both whole body and torso thermal sensations were improved. The findings indicate that the personal cooling with PCM can be used as an option to improve thermal comfort for office workers without air conditioning and may be used for vulnerable groups, such as elderly people, when confronted with heat waves. Wearable personal cooling integrated with phase change materials has the advantage of cooling human body's micro-environment in contrast to stationary personalized cooling and entire room or building cooling, thus providing greater mobility and helping to save energy. In places where air conditioning is not usually used, this personal cooling method can be used as a preventive measure when confronted with heat waves for office workers, vulnerable populations such as the elderly and disabled people, people with chronic diseases, and for use at home. © 2012 John Wiley & Sons A/S.

  17. Detection of skeletal muscle metastasis: torso FDG PET-CT versus contrast-enhanced chest or abdomen CT.

    PubMed

    So, Young; Yi, Jeong Geun; Song, Inyoung; Lee, Won Woo; Chung, Hyun Woo; Park, Jeong Hee; Moon, Sung Gyu

    2015-07-01

    Skeletal muscle metastasis (SMM) in cancer patients has not been sufficiently evaluated regarding prevalence and proper method of detection. To determine the prevalence of SMM and compare the diagnostic competencies for SMM of torso F-18 fluorodeoxyglucose (FDG) positron emission tomography-computed tomography (PET-CT) and contrast-enhanced chest or abdomen CT. We investigated 18,225 PET-CT studies of 6359 cancer patients performed from 2005 to 2012. The PET-CT studies describing potential SMM were retrieved and the corresponding medical records were reviewed. The gold standard for SMM was histopathologically-proven SMM or imaging study-based disease progression. The detectability of SMM was compared between PET-CT and contrast-enhanced CT. Twenty-six patients had 84 SMM lesions, representing a SMM prevalence of 0.41%. Lung cancer was the most common SMM-associated malignancy (54%) and the gluteal/pelvic girdle muscle was the most frequently involved SMM site (37%). All 84 SMM lesions were visualized on PET-CT (100%). Of these PET-CT positive 84 SMM lesions, 51 lesions were in the CT field of view (FOV) (61%), whereas 33 lesions were out of the CT FOV (39%). Among these 51 lesions, 17 lesions showed rim-enhancing nodules/masses (33%), eight lesions showed homogeneously enhancing nodules (16%), three lesions showed heterogeneously enhancing nodules (6%), and 23 SMM lesions (45%) were non-diagnostic by CT. All 51 SMM lesions within CT FOV were detected on PET-CT (100%), whereas only 28 were visualized on CT (54.9%), resulting in a significant difference (P < 0.005). On average, 2.6 more organs with concomitant metastases were found when SMM was revealed by PET-CT. The prevalence of SMM was as low as 0.41% in the current large cohort of cancer patients. Torso PET-CT was a more competent modality than contrast-enhanced CT in the detection of SMM. © The Foundation Acta Radiologica 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  18. Optimization of cyanide extraction from wastewater using emulsion liquid membrane system by response surface methodology.

    PubMed

    Xue, Juan Qin; Liu, Ni Na; Li, Guo Ping; Dang, Long Tao

    To solve the disposal problem of cyanide wastewater, removal of cyanide from wastewater using a water-in-oil emulsion type of emulsion liquid membrane (ELM) was studied in this work. Specifically, the effects of surfactant Span-80, carrier trioctylamine (TOA), stripping agent NaOH solution and the emulsion-to-external-phase-volume ratio on removal of cyanide were investigated. Removal of total cyanide was determined using the silver nitrate titration method. Regression analysis and optimization of the conditions were conducted using the Design-Expert software and response surface methodology (RSM). The actual cyanide removals and the removals predicted using RSM analysis were in close agreement, and the optimal conditions were determined to be as follows: the volume fraction of Span-80, 4% (v/v); the volume fraction of TOA, 4% (v/v); the concentration of NaOH, 1% (w/v); and the emulsion-to-external-phase volume ratio, 1:7. Under the optimum conditions, the removal of total cyanide was 95.07%, and the RSM predicted removal was 94.90%, with a small exception. The treatment of cyanide wastewater using an ELM is an effective technique for application in industry.

  19. [Minimal provider volume in total knee replacement : an analysis of the external quality assurance program of North Rhine-Westphalia (QS-NRW)].

    PubMed

    Kostuj, T; Schulze-Raestrup, U; Noack, M; Buckup, K; Smektala, R

    2011-05-01

    A minimal provider volume for total knee replacement (TKR) was introduced in 2006. Does this lead to an improvenment in quality or not? The records of treatment in the compulsory external quality assurance program of the Land of North Rhine-Westphalia (QS-NRW) were evaluated. A total of 125,324 comparable records from the QS-NRW program were available to determine the appearance of general and surgical complications. In a logistical regression model the risk factors age, gender, ASA classification, comorbidity and duration were taken into account. A significant reduction could only be shown for pneumonia, thrombotic events and lung embolisms as well as vascular injury. In 2006 and 2007 malpositioning of implants was significantly higher and from 2005 to 2008 the number of fractures rose compared to 2004. Deep infections and reoperations did not change significantly during the whole study period. This evaluation could not show an improvement in quality due to the minimal provider volume. Thus the minimal provider volume should not be taken into account as a main criterion to improve quality. Further outcome studies and creating an arthroplasty register in Germany are more useful.

  20. Comparison of Q3s ATD biomechanical responses to pediatric volunteers.

    PubMed

    Ita, Meagan; Kang, Yun-Seok; Seacrist, Thomas; Dahle, Eric; Bolte, John

    2014-01-01

    The biofidelity of pediatric anthropomorphic test devices (ATDs) continues to be evaluated with scaled-down adult data, a methodology that requires inaccurate assumptions about the likeness of biomechanical properties of children and adults. Recently, evaluation of pediatric ATDs by comparison of pediatric volunteer (PV) data has emerged as a valuable and practical alternative to the use of scaled adult data. This study utilized existing PV data to evaluate a 3-year-old side impact ATD, the Q3s. Though ATDs have been compared to volunteer responses in frontal impacts, this study is the first to extend ATD-PV comparison methods to the Q3s ATD and among the first to extend these methods to side impacts. Previously conducted experiments were replicated in order to make a direct comparison between the Q3s and PVs. PV data were used from 4- to 7-year-olds (shoulder tests, n=14) and 6- to 8-year-olds (sled tests, n=7). Force-deflection data were captured during quasistatic shoulder tests through manual displacement of the shoulder joint. Resulting shoulder stiffness was compared between the Q3s and PVs. Low-speed far-side sled tests were conducted with the Q3s at lateral (90°) and oblique (60°) impacts. Primary outcomes of interest included (1) lateral displacement of the torso, (2) torso rollout angle, and (3) kinematic trajectories of the head and neck. The Q3s exhibited shoulder stiffness values at least 32 N/mm greater than the PVs for all conditions (PV muscle tensed and relaxed, deflection calculated for full- and half-thoracic). In lateral sled tests, the Q3s demonstrated increased coronal torso rollout (Q3s: 49.2°; PVs: 35.7°±12.4°) and lateral (ΔY) movement of the top of the head (Q3s: -389 mm; PVs: -320±23 mm) compared to PVs. In oblique trials, the Q3s achieved significantly decreased lateral torso displacement (Q3s: 153.3 mm; PVs: 193.6±25.6 mm) and top of the head forward (ΔX) motion (Q3s: 68 mm; PVs: 133 ± 20 mm) compared to PVs. In all tests, greater downward (ΔZ) excursions of C4 and T1 were observed in the Q3s relative to PVs. Increased Q3s shoulder stiffness could affect head-neck kinematics as well as thorax responses because unrealistic force can be transmitted to the spine from the shoulder. Q3s and PV trajectories were of similar shape, although Q3s head kinematics displayed rigid body motion followed by independent lateral bending of the head, suggesting cervical and thoracic spine rigidity compared to PVs.

  1. Magnitude of Interfractional Vaginal Cuff Movement: Implications for External Irradiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ma, Daniel J.; Michaletz-Lorenz, Martha; Goddu, S. Murty

    2012-03-15

    Purpose: To quantify the extent of interfractional vaginal cuff movement in patients receiving postoperative irradiation for cervical or endometrial cancer in the absence of bowel/bladder instruction. Methods and Materials: Eleven consecutive patients with cervical or endometrial cancer underwent placement of three gold seed fiducial markers in the vaginal cuff apex as part of standard of care before simulation. Patients subsequently underwent external irradiation and brachytherapy treatment based on institutional guidelines. Daily megavoltage CT imaging was performed during each external radiation treatment fraction. The daily positions of the vaginal apex fiducial markers were subsequently compared with the original position of themore » fiducial markers on the simulation CT. Composite dose-volume histograms were also created by summing daily target positions. Results: The average ({+-} standard deviation) vaginal cuff movement throughout daily pelvic external radiotherapy when referenced to the simulation position was 16.2 {+-} 8.3 mm. The maximum vaginal cuff movement for any patient during treatment was 34.5 mm. In the axial plane the mean vaginal cuff movement was 12.9 {+-} 6.7 mm. The maximum vaginal cuff axial movement was 30.7 mm. In the craniocaudal axis the mean movement was 10.3 {+-} 7.6 mm, with a maximum movement of 27.0 mm. Probability of cuff excursion outside of the clinical target volume steadily dropped as margin size increased (53%, 26%, 4.2%, and 1.4% for 1.0, 1.5, 2.0, and 2.5 cm, respectively.) However, rectal and bladder doses steadily increased with larger margin sizes. Conclusions: The magnitude of vaginal cuff movement is highly patient specific and can impact target coverage in patients without bowel/bladder instructions at simulation. The use of vaginal cuff fiducials can help identify patients at risk for target volume excursion.« less

  2. Using a whole-body 31P birdcage transmit coil and 16-element receive array for human cardiac metabolic imaging at 7T

    PubMed Central

    Dragonu, Iulius; Almujayyaz, Salam; Batzakis, Alex; Young, Liam A. J.; Purvis, Lucian A. B.; Clarke, William T.; Wichmann, Tobias; Lanz, Titus; Neubauer, Stefan; Robson, Matthew D.; Klomp, Dennis W. J.; Rodgers, Christopher T.

    2017-01-01

    Purpose Cardiac phosphorus magnetic resonance spectroscopy (31P-MRS) provides unique insight into the mechanisms of heart failure. Yet, clinical applications have been hindered by the restricted sensitivity of the surface radiofrequency-coils normally used. These permit the analysis of spectra only from the interventricular septum, or large volumes of myocardium, which may not be meaningful in focal disease. Löring et al. recently presented a prototype whole-body (52 cm diameter) transmit/receive birdcage coil for 31P at 7T. We now present a new, easily-removable, whole-body 31P transmit radiofrequency-coil built into a patient-bed extension combined with a 16-element receive array for cardiac 31P-MRS. Materials and methods A fully-removable (55 cm diameter) birdcage transmit coil was combined with a 16-element receive array on a Magnetom 7T scanner (Siemens, Germany). Electro-magnetic field simulations and phantom tests of the setup were performed. In vivo maps of B1+, metabolite signals, and saturation-band efficiency were acquired across the torsos of eight volunteers. Results The combined (volume-transmit, local receive array) setup increased signal-to-noise ratio 2.6-fold 10 cm below the array (depth of the interventricular septum) compared to using the birdcage coil in transceiver mode. The simulated coefficient of variation for B1+ of the whole-body coil across the heart was 46.7% (surface coil 129.0%); and the in vivo measured value was 38.4%. Metabolite images of 2,3-diphosphoglycerate clearly resolved the ventricular blood pools, and muscle tissue was visible in phosphocreatine (PCr) maps. Amplitude-modulated saturation bands achieved 71±4% suppression of phosphocreatine PCr in chest-wall muscles. Subjects reported they were comfortable. Conclusion This easy-to-assemble, volume-transmit, local receive array coil combination significantly improves the homogeneity and field-of-view for metabolic imaging of the human heart at 7T. PMID:29073228

  3. External validation of change formulae in neuropsychology with neuroimaging biomarkers: a methodological recommendation and preliminary clinical data.

    PubMed

    Duff, Kevin; Suhrie, Kayla R; Dalley, Bonnie C A; Anderson, Jeffrey S; Hoffman, John M

    2018-06-08

    Within neuropsychology, a number of mathematical formulae (e.g. reliable change index, standardized regression based) have been used to determine if change across time has reliably occurred. When these formulae have been compared, they often produce different results, but 'different' results do not necessarily indicate which formulae are 'best.' The current study sought to further our understanding of change formulae by comparing them to clinically relevant external criteria (amyloid deposition and hippocampal volume). In a sample of 25 older adults with varying levels of cognitive intactness, participants were tested twice across one week with a brief cognitive battery. Seven different change scores were calculated for each participant. An amyloid PET scan (to get a composite of amyloid deposition) and an MRI (to get hippocampal volume) were also obtained. Deviation-based change formulae (e.g. simple discrepancy score, reliable change index with or without correction for practice effects) were all identical in their relationship to the two neuroimaging biomarkers, and all were non-significant. Conversely, regression-based change formulae (e.g. simple and complex indices) showed stronger relationships to amyloid deposition and hippocampal volume. These results highlight the need for external validation of the various change formulae used by neuropsychologists in clinical settings and research projects. The findings also preliminarily suggest that regression-based change formulae may be more relevant than deviation-based change formulae in this context.

  4. Highlights from the previous volumes

    NASA Astrophysics Data System (ADS)

    -C., Liu K.; al., Kumar N. et; al., Anishchenko V. et; al., Jaeckel J. et; et al.

    2009-10-01

    The physics of pizza tossing and the next generation of micromotors Is diamagnetism possible classically? Phase dynamics of two coupled oscillators under external periodic force Optical communications through dense matter

  5. Dual-projection 3D-2D registration for surgical guidance: preclinical evaluation of performance and minimum angular separation

    NASA Astrophysics Data System (ADS)

    Uneri, A.; Otake, Y.; Wang, A. S.; Kleinszig, G.; Vogt, S.; Gallia, G. L.; Rigamonti, D.; Wolinsky, J.-P.; Gokaslan, Ziya L.; Khanna, A. J.; Siewerdsen, J. H.

    2014-03-01

    An algorithm for 3D-2D registration of CT and x-ray projections has been developed using dual projection views to provide 3D localization with accuracy exceeding that of conventional tracking systems. The registration framework employs a normalized gradient information (NGI) similarity metric and covariance matrix adaptation evolution strategy (CMAES) to solve for the patient pose in 6 degrees of freedom. Registration performance was evaluated in anthropomorphic head and chest phantoms, as well as a human torso cadaver, using C-arm projection views acquired at angular separations (Δ𝜃) ranging 0-178°. Registration accuracy was assessed in terms target registration error (TRE) and compared to that of an electromagnetic tracker. Studies evaluated the influence of C-arm magnification, x-ray dose, and preoperative CT slice thickness on registration accuracy and the minimum angular separation required to achieve TRE ~2 mm. The results indicate that Δ𝜃 as small as 10-20° is adequate to achieve TRE <2 mm with 95% confidence, comparable or superior to that of commercial trackers. The method allows direct registration of preoperative CT and planning data to intraoperative fluoroscopy, providing 3D localization free from conventional limitations associated with external fiducial markers, stereotactic frames, trackers, and manual registration. The studies support potential application to percutaneous spine procedures and intracranial neurosurgery.

  6. Trunk Muscle Activation and Estimating Spinal Compressive Force in Rope and Harness Vertical Dance.

    PubMed

    Wilson, Margaret; Dai, Boyi; Zhu, Qin; Humphrey, Neil

    2015-12-01

    Rope and harness vertical dance takes place off the floor with the dancer suspended from his or her center of mass in a harness attached to a rope from a point overhead. Vertical dance represents a novel environment for training and performing in which expected stresses on the dancer's body are different from those that take place during dance on the floor. Two male and eleven female dancers with training in vertical dance performed six typical vertical dance movements with electromyography (EMG) electrodes placed bilaterally on rectus abdominus, external oblique, erector spinae, and latissimus dorsi. EMG data were expressed as a percentage of maximum voluntary isometric contraction (MVIC). A simplified musculoskeletal model based on muscle activation for these four muscle groups was used to estimate the compressive force on the spine. The greatest muscle activation for erector spinae and latissimus dorsi and the greatest trunk compressive forces were seen in vertical axis positions where the dancer was moving the trunk into a hyper-extended position. The greatest muscle activation for rectus abdominus and external oblique and the second highest compressive force were seen in a supine position with the arms and legs extended away from the center of mass (COM). The least muscle activation occurred in positions where the limbs were hanging below the torso. These movements also showed relatively low muscle activation compression forces. Post-test survey results revealed that dancers felt comfortable in these positions; however, observation of some positions indicated insufficient muscular control. Computing the relative contribution of muscles, expressed as muscle activation and estimated spinal compression, provided a measure of how much the muscle groups were working to support the spine and the rest of the dancer's body in the different movements tested. Additionally, identifying typical muscle recruitment patterns in each movement will help identify key exercises for training that should promote injury prevention.

  7. Creating Clay Models of a Human Torso as an Alternative to Dissection

    ERIC Educational Resources Information Center

    Shipley, Gwendolyn

    2010-01-01

    Instead of dissecting animals, students create small clay models of human internal organs to demonstrate their understanding of the positioning and interlocking shapes of the organs. Not only is this approach more environmentally friendly, it also forces them to learn human anatomy--which is more relevant to them than the anatomy of other…

  8. Prospective Evaluation of the Correlation Between Torso Height and Aortic Anatomy in Respect of a Fluoroscopy Free Aortic Balloon Occlusion System

    DTIC Science & Technology

    2014-06-01

    austere circumstances, providing a physiologic bridge to definitive hemorrhage control. The clinical use of this technique was first described in the...Support Hospital in Camp Bastion , Helmand Province, Southern Afghanistan. This hospital is unique in the theater of Afghanistan as it is a joint UK–US

  9. Biomechanical Assessment of Rucksack Shoulder Strap Attachment Location: Effect on Load Distribution to the Torso

    DTIC Science & Technology

    2001-05-01

    varied vertical heights and horizontal positions. Optotrak position markers indicated by white diamonds). The position and mass of the payload (25 kg...shoulders and 45 N (+/- 2) at the waist and recorded for all configurations. An Optotrak 3-D motion tracking system, accuracy +/- 0.1 mm, was used to

  10. 14 CFR 27.785 - Seats, berths, litters, safety belts, and harnesses.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... head injury by a safety belt plus a shoulder harness that will prevent the head from contacting any injurious object except as provided for in § 27.562(c)(5). A shoulder harness (upper torso restraint), in... serious injury in an emergency landing as a result of the static inertial load factors specified in § 27...

  11. 14 CFR 27.785 - Seats, berths, litters, safety belts, and harnesses.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... head injury by a safety belt plus a shoulder harness that will prevent the head from contacting any injurious object except as provided for in § 27.562(c)(5). A shoulder harness (upper torso restraint), in... serious injury in an emergency landing as a result of the static inertial load factors specified in § 27...

  12. 14 CFR 27.785 - Seats, berths, litters, safety belts, and harnesses.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... head injury by a safety belt plus a shoulder harness that will prevent the head from contacting any injurious object except as provided for in § 27.562(c)(5). A shoulder harness (upper torso restraint), in... serious injury in an emergency landing as a result of the static inertial load factors specified in § 27...

  13. 14 CFR 27.785 - Seats, berths, litters, safety belts, and harnesses.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... head injury by a safety belt plus a shoulder harness that will prevent the head from contacting any injurious object except as provided for in § 27.562(c)(5). A shoulder harness (upper torso restraint), in... serious injury in an emergency landing as a result of the static inertial load factors specified in § 27...

  14. Comparative Assessment of Torso and Seat Mounted Restraint Systems using Manikins on the Vertical Deceleration Tower

    DTIC Science & Technology

    2017-03-01

    experimental effort involving a series of +z-axis impact tests was conducted on the 711th Human Performance Wing’s Vertical Deceleration Tower (VDT...parameters) and a JSF-styled ejection seat configuration (combined non -baseline test parameters) produced similar biodynamic response parameters for the LOIS...Photography .............................................................................. 12 6.0 EXPERIMENTAL DESIGN

  15. 49 CFR 572.185 - Thorax (upper torso) assembly.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... impactor at contact with the thorax. The non-struck side arm is oriented vertically, pointing downward. The...); (iv) The impactor is guided, if needed, so that at contact with the thorax its longitudinal axis is... rib not less than 37 mm and not greater than 44 mm. (ii) The impactor force shall be computed as the...

  16. 49 CFR 572.185 - Thorax (upper torso) assembly.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... impactor at contact with the thorax. The non-struck side arm is oriented vertically, pointing downward. The...); (iv) The impactor is guided, if needed, so that at contact with the thorax its longitudinal axis is... rib not less than 37 mm and not greater than 44 mm. (ii) The impactor force shall be computed as the...

  17. 49 CFR 572.185 - Thorax (upper torso) assembly.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... impactor at contact with the thorax. The non-struck side arm is oriented vertically, pointing downward. The...); (iv) The impactor is guided, if needed, so that at contact with the thorax its longitudinal axis is... rib not less than 37 mm and not greater than 44 mm. (ii) The impactor force shall be computed as the...

  18. 49 CFR 572.185 - Thorax (upper torso) assembly.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... impactor at contact with the thorax. The non-struck side arm is oriented vertically, pointing downward. The...); (iv) The impactor is guided, if needed, so that at contact with the thorax its longitudinal axis is... rib not less than 37 mm and not greater than 44 mm. (ii) The impactor force shall be computed as the...

  19. 49 CFR 572.185 - Thorax (upper torso) assembly.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... impactor at contact with the thorax. The non-struck side arm is oriented vertically, pointing downward. The...); (iv) The impactor is guided, if needed, so that at contact with the thorax its longitudinal axis is... rib not less than 37 mm and not greater than 44 mm. (ii) The impactor force shall be computed as the...

  20. Flight Physical Standards of the 1980’s: Spinal Column Considerations

    DTIC Science & Technology

    1979-10-01

    disease and spondylosis deformans. In addition, the role of vertebral body fractures oni subsequent spinal column impact is discussed. SECURITY...11 Spondylosis D eform ans ......................................... ................... 11 III...5th lumbar vertebra supports the superimposed weight of the torso upon the inclined plane of the sacrum. The necessity for bony continuity of the 5th

  1. The Kinetic Energy of a Rotating Figure Skater.

    ERIC Educational Resources Information Center

    Chen, Wei R.; Troelstra, Arne A.

    1998-01-01

    When a rotating figure skater's fully extended arms are pulled back toward the torso, the angular velocity is noticeably increased and the kinetic energy of the skater can also be shown to increase. Discusses the change of the kinetic energy during such a process, and the work necessary for such an increase is derived using a dynamic equilibrium…

  2. Endochondral fracture healing with external fixation in the Sost knockout mouse results in earlier fibrocartilage callus removal and increased bone volume fraction and strength.

    PubMed

    Morse, A; Yu, N Y C; Peacock, L; Mikulec, K; Kramer, I; Kneissel, M; McDonald, M M; Little, D G

    2015-02-01

    Sclerostin deficiency, via genetic knockout or anti-Sclerostin antibody treatment, has been shown to cause increased bone volume, density and strength of calluses following endochondral bone healing. However, there is limited data on the effect of Sclerostin deficiency on the formative early stage of fibrocartilage (non-bony tissue) formation and removal. In this study we extensively investigate the early fibrocartilage callus. Closed tibial fractures were performed on Sost(-/-) mice and age-matched wild type (C57Bl/6J) controls and assessed at multiple early time points (7, 10 and 14days), as well as at 28days post-fracture after bony union. External fixation was utilized, avoiding internal pinning and minimizing differences in stability stiffness, a variable that has confounded previous research in this area. Normal endochondral ossification progressed in wild type and Sost(-/-) mice with equivalent volumes of fibrocartilage formed at early day 7 and day 10 time points, and bony union in both genotypes by day 28. There were no significant differences in rate of bony union; however there were significant increases in fibrocartilage removal from the Sost(-/-) fracture calluses at day 14 suggesting earlier progression of endochondral healing. Earlier bone formation was seen in Sost(-/-) calluses over wild type with greater bone volume at day 10 (221%, p<0.01). The resultant Sost(-/-) united bony calluses at day 28 had increased bone volume fraction compared to wild type calluses (24%, p<0.05), and the strength of the fractured Sost(-/-) tibiae was greater than that that of wild type fractured tibiae. In summary, bony union was not altered by Sclerostin deficiency in externally-fixed closed tibial fractures, but fibrocartilage removal was enhanced and the resultant united bony calluses had increased bone fraction and increased strength. Crown Copyright © 2014. Published by Elsevier Inc. All rights reserved.

  3. Residual tumour volumes and grey zones after external beam radiotherapy (with or without chemotherapy) in cervical cancer patients. A low-field MRI study.

    PubMed

    Schmid, M P; Mansmann, B; Federico, M; Dimopoulous, J C A; Georg, P; Fidarova, E; Dörr, W; Pötter, R

    2013-03-01

    Grey zones, which are defined as tissue with intermediate signal intensity in the area of primary hyperintense tumour extension, can be seen during radiation with or without chemotherapy on the T2-weighted MRI in patients with cervical cancer. The purpose of this study was to systematically measure the tumour volume at the time of diagnosis and the residual tumour volume at the time of brachytherapy without and with consideration of the grey zones and to estimate tumour regression during external beam radiotherapy (EBRT). T2-weighted MRI datasets of 175 patients with locally advanced cervical cancer (FIGO stage IB-IVA), who underwent combined external beam radiotherapy and brachytherapy with or without concomitant chemotherapy were available for this study. The gross tumour volume at the time of diagnosis (GTV(init)) and at the time of first brachytherapy without (GTV(res)) and with (GTV(res)+ GZ) consideration of grey zones were measured for each patient. A descriptive statistical analysis was performed and tumour regression rates without (R) and with consideration of grey zones (R(GZ)) were calculated. Further, the role of prognostic factors on GTV(init), GTV(res), GTV(res)+ GZ and tumour regression rates was investigated. The median GTV(init), GTV(res), GTV(res)+ GZ in all patients were 44.4 cm(3), 8.2 cm(3), 20.3 cm(3), respectively. The median R was 78.5% and the median R(GZ) was 50.1%. The histology and FIGO staging showed a significant impact on GTV(init), GTV(res) and GTV(res)+ GZ. Grey zones represent a substantial proportion of the residual tumour volume at the time of brachytherapy. Differentiation of high signal intensity mass and surrounding intermediate signal intensity grey zones may be reasonable.

  4. A three-dimensional analysis of the endolymph drainage system in Ménière disease.

    PubMed

    Monsanto, Rafael da Costa; Pauna, Henrique F; Kwon, Geeyoun; Schachern, Patricia A; Tsuprun, Vladimir; Paparella, Michael M; Cureoglu, Sebahattin

    2017-05-01

    To measure the volume of the endolymph drainage system in temporal bone specimens with Ménière disease, as compared with specimens with endolymphatic hydrops without vestibular symptoms and with nondiseased specimens STUDY DESIGN: Comparative human temporal bone analysis. We generated three-dimensional models of the vestibular aqueduct, endolymphatic sinus and duct, and intratemporal portion of the endolymphatic sac and calculated the volume of those structures. We also measured the internal and external aperture of the vestibular aqueduct, as well as the opening (if present) of the utriculoendolymphatic (Bast's) valve and compared the measurements in our three study groups. The volume of the vestibular aqueduct and of the endolymphatic sinus, duct, and intratemporal endolymphatic sac was significantly lower in the Ménière disease group than in the endolymphatic hydrops group (P <.05). The external aperture of the vestibular aqueduct was also smaller in the Ménière disease group. Bast's valve was open only in some specimens in the Ménière disease group. In temporal bones with Ménière disease, the volume of the vestibular aqueduct, endolymphatic duct, and intratemporal endolymphatic sac was lower, and the external aperture of the vestibular aqueduct was smaller as compared with bones from donors who had endolymphatic hydrops without vestibular symptoms and with nondiseased bones. The open status of the Bast's valve in the Ménière disease group could be secondary to higher retrograde endolymph pressures caused by smaller drainage systems. These anatomic findings could correlate with the reason that some patients with hydrops develop clinical symptoms, whereas others do not. N/A Laryngoscope, 127:E170-E175, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  5. Frequency-dependent left ventricular performance in women and men.

    PubMed

    Wainstein, Rodrigo V; Sasson, Zion; Mak, Susanna

    2012-06-01

    We aimed to determine whether sex differences in humans extend to the dynamic response of the left ventricular (LV) chamber to changes in heart rate (HR). Several observations suggest sex influences LV structure and function in health; moreover, this physiology is also affected in a sex-specific manner by aging. Eight postmenopausal women and eight similarly aged men underwent a cardiac catheterization-based study for force-interval relationships of the LV. HR was controlled by right atrial (RA) pacing, and LV +dP/dt(max) and volume were assessed by micromanometer-tipped catheter and Doppler echocardiography, respectively. Analysis of approximated LV pressure-volume relationships was performed using a time-varying model of elastance. External stroke work was also calculated. The relationship between HR and LV +dP/dt(max) was expressed as LV +dP/dt(max) = b + mHR. The slope (m) of the relationship was steeper in women compared with men (11.8 ± 4.0 vs. 6.1 ± 4.1 mmHg·s(-1)·beats(-1)·min(-1), P = 0.01). The greater increase in contractility in women was reproducibly observed after normalizing LV +dP/dt(max) to LV end-diastolic volume (LVVed) or by measuring end-systolic elastance. LVVed and stroke volume decreased more in women. Thus, despite greater increases in contractility, HR was associated with a lesser rise in cardiac output and a steeper fall in external stroke work in women. Compared with men, women exhibit greater inotropic responses to incremental RA pacing, which occurs at the same time as a steeper decline in external stroke work. In older adults, we observed sexual dimorphism in determinants of LV mechanical performance.

  6. Large volume multiple-path nuclear pumped laser

    NASA Technical Reports Server (NTRS)

    Hohl, F.; Deyoung, R. J. (Inventor)

    1981-01-01

    Large volumes of gas are excited by using internal high reflectance mirrors that are arranged so that the optical path crosses back and forth through the excited gaseous medium. By adjusting the external dielectric mirrors of the laser, the number of paths through the laser cavity can be varied. Output powers were obtained that are substantially higher than the output powers of previous nuclear laser systems.

  7. External beam pixe programs at the University of California, Davis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eldred, R.A.

    A PIXE system in which large or delicate samples are excited by a low-current external proton beam is described. This system has been used to analyze historical printed books and manuscripts, as well as a large variety of archeological artifacts. The steps used to protect the sample from unnecessary beam current are examined. A recent thorough study of the first volume of the Gutenberg 42-line Bible is described in some detail.

  8. ESP (External-Stores Program) - A Pilot Computer Program for Determining Flutter-Critical External-Store Configurations. Volume 1. User’s Manual,

    DTIC Science & Technology

    1985-02-01

    li’Lii El. IE F INE ,UT 1 = K MM. * GET, NAST484/UN=SYSTEM. E(EGIN, ,NAST464. PFL, 160000, RED’UCE(-). LINKI , L~DDEDDD Figure A-I1 Typical Control-Card...initiated via Che LINKI statement, in which the second term is the input data file. The permanent file name KMDM, shown in conjunction with local file

  9. Minutes of the Explosives Safety Seminar (24th) Held in St. Louis, Missouri on 28-30 August 1990. Volume 1

    DTIC Science & Technology

    1990-08-30

    concrete-soil-concrete and other soil-filled elements as well as earth embankments of different shapes. The design of the shielding external walls...to vent entirely through the doors. This was required because the large amount of earth fill on the roofs, required for radiation shielding , precluded...Safety Window Shield to Protect Against External Explosions ...... ............... ................... 783 R. L. Shope, W. A. Keenan Strenghtening

  10. Room temperature stretch forming of scale space shuttle external tank dome gores. Volume 1: Technical

    NASA Technical Reports Server (NTRS)

    Blunck, R. D.; Krantz, D. E.

    1974-01-01

    An account of activities and data gathered in the Room Temperature Stretch Forming of One-third Scale External Tank Bulkhead Gores for space shuttle study, and a tooling design and production cost study are reported. The following study phases are described: (1) the stretch forming of three approximately one-third scale external tank dome gores from single sheets of 2219-T37 aluminum alloy; (2) the designing of a full scale production die, including a determination of tooling requirements; and (3) the determination of cost per gore at the required production rates, including manufacturing, packaging, and shipping.

  11. Configurable, wearable sensing and vibrotactile feedback system for real-time postural balance and gait training: proof-of-concept.

    PubMed

    Xu, Junkai; Bao, Tian; Lee, Ung Hee; Kinnaird, Catherine; Carender, Wendy; Huang, Yangjian; Sienko, Kathleen H; Shull, Peter B

    2017-10-11

    Postural balance and gait training is important for treating persons with functional impairments, however current systems are generally not portable and are unable to train different types of movements. This paper describes a proof-of-concept design of a configurable, wearable sensing and feedback system for real-time postural balance and gait training targeted for home-based treatments and other portable usage. Sensing and vibrotactile feedback are performed via eight distributed, wireless nodes or "Dots" (size: 22.5 × 20.5 × 15.0 mm, weight: 12.0 g) that can each be configured for sensing and/or feedback according to movement training requirements. In the first experiment, four healthy older adults were trained to reduce medial-lateral (M/L) trunk tilt while performing balance exercises. When trunk tilt deviated too far from vertical (estimated via a sensing Dot on the lower spine), vibrotactile feedback (via feedback Dots placed on the left and right sides of the lower torso) cued participants to move away from the vibration and back toward the vertical no feedback zone to correct their posture. A second experiment was conducted with the same wearable system to train six healthy older adults to alter their foot progression angle in real-time by internally or externally rotating their feet while walking. Foot progression angle was estimated via a sensing Dot adhered to the dorsal side of the foot, and vibrotactile feedback was provided via feedback Dots placed on the medial and lateral sides of the mid-shank cued participants to internally or externally rotate their foot away from vibration. In the first experiment, the wearable system enabled participants to significantly reduce trunk tilt and increase the amount of time inside the no feedback zone. In the second experiment, all participants were able to adopt new gait patterns of internal and external foot rotation within two minutes of real-time training with the wearable system. These results suggest that the configurable, wearable sensing and feedback system is portable and effective for different types of real-time human movement training and thus may be suitable for home-based or clinic-based rehabilitation applications.

  12. Radiographic evaluation of vessel count and density with quantitative magnetic resonance imaging during external breast expansion in Asian women: A prospective clinical trial.

    PubMed

    Myung, Yujin; Kwon, Heeyeon; Pak, Changsik; Lee, Hobin; Jeong, Jae Hoon; Heo, Chan Yeong

    2016-12-01

    Breast augmentation with fat transfer does not bear the risks associated with silicone implantation. The method can potentially be especially useful in Asian women, who often reject augmentation mammoplasty with implants. This prospective clinical trial evaluated the effects of external breast expansion on breast density and vessel count using magnetic resonance imaging. Thirty-four enrolled patients were instructed to apply one of two devices, the conventional BRAVA device (used in the AESTES trial) or a novel external expansion device (EVERA) designed for Asian women, continuously for 8 h per day for 12 weeks. For external expansion, the pressure was set to 25 mmHg. Follow-up examinations were performed for 4 weeks after completion of the expansion. The ratio between the fibroglandular and adipose tissues of the breast was measured using T1-weighted MRI, and the number of vessels in the breast tissue was determined before and after the treatment by contrast MRI. Additionally, the volume of the breast was measured by laser scanning before, during, and after the device application. The obtained measurements were compared within and between the groups at different time points. Six patients dropped out, while 28 completed the trial without major side effects or adverse events. External expansion significantly increased breast vessel count in both the EVERA and AESTES groups (p = 0.019, p = 0.022). However, it did not significantly change breast density in either group (p = 0.186, p = 0.638). No significant intergroup differences were noted in vessel count (p = 0.874) or density (p = 0.482). Breast volume increases after 12 weeks of application were statistically significant in both groups, with mean changes of 81 ± 22 cc (AESTES) and 98 ± 30 cc (EVERA) (p < 0.001 in both cases). External expansion resulted in a marked increase in breast vessel count but did not affect breast density. The observed increase in breast volume can be considered substantial for Asian women. Level II, therapeutic study. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  13. Detection of gas leakage

    DOEpatents

    Thornberg, Steven [Peralta, NM; Brown, Jason [Albuquerque, NM

    2012-06-19

    A method of detecting leaks and measuring volumes as well as an apparatus, the Power-free Pump Module (PPM), that is a self-contained leak test and volume measurement apparatus that requires no external sources of electrical power during leak testing or volume measurement, where the invention is a portable, pneumatically-controlled instrument capable of generating a vacuum, calibrating volumes, and performing quantitative leak tests on a closed test system or device, all without the use of alternating current (AC) power. Capabilities include the ability is to provide a modest vacuum (less than 10 Torr), perform a pressure rise leak test, measure the gas's absolute pressure, and perform volume measurements. All operations are performed through a simple rotary control valve which controls pneumatically-operated manifold valves.

  14. Detection of gas leakage

    DOEpatents

    Thornberg, Steven M; Brown, Jason

    2015-02-17

    A method of detecting leaks and measuring volumes as well as a device, the Power-free Pump Module (PPM), provides a self-contained leak test and volume measurement apparatus that requires no external sources of electrical power during leak testing or volume measurement. The PPM is a portable, pneumatically-controlled instrument capable of generating a vacuum, calibrating volumes, and performing quantitative leak tests on a closed test system or device, all without the use of alternating current (AC) power. Capabilities include the ability is to provide a modest vacuum (less than 10 Torr) using a venturi pump, perform a pressure rise leak test, measure the gas's absolute pressure, and perform volume measurements. All operations are performed through a simple rotary control valve which controls pneumatically-operated manifold valves.

  15. Three-dimensional cinematography with control object of unknown shape.

    PubMed

    Dapena, J; Harman, E A; Miller, J A

    1982-01-01

    A technique for reconstruction of three-dimensional (3D) motion which involves a simple filming procedure but allows the deduction of coordinates in large object volumes was developed. Internal camera parameters are calculated from measurements of the film images of two calibrated crosses while external camera parameters are calculated from the film images of points in a control object of unknown shape but at least one known length. The control object, which includes the volume in which the activity is to take place, is formed by a series of poles placed at unknown locations, each carrying two targets. From the internal and external camera parameters, and from locations of the images of point in the films of the two cameras, 3D coordinates of the point can be calculated. Root mean square errors of the three coordinates of points in a large object volume (5m x 5m x 1.5m) were 15 mm, 13 mm, 13 mm and 6 mm, and relative errors in lengths averaged 0.5%, 0.7% and 0.5%, respectively.

  16. Parasite fitness traits under environmental variation: disentangling the roles of a chytrid's immediate host and external environment.

    PubMed

    Van den Wyngaert, Silke; Vanholsbeeck, Olivier; Spaak, Piet; Ibelings, Bas W

    2014-10-01

    Parasite environments are heterogeneous at different levels. The first level of variability is the host itself. The second level represents the external environment for the hosts, to which parasites may be exposed during part of their life cycle. Both levels are expected to affect parasite fitness traits. We disentangle the main and interaction effects of variation in the immediate host environment, here the diatom Asterionella formosa (variables host cell volume and host condition through herbicide pre-exposure) and variation in the external environment (variables host density and acute herbicide exposure) on three fitness traits (infection success, development time and reproductive output) of a chytrid parasite. Herbicide exposure only decreased infection success in a low host density environment. This result reinforces the hypothesis that chytrid zoospores use photosynthesis-dependent chemical cues to locate its host. At high host densities, chemotaxis becomes less relevant due to increasing chance contact rates between host and parasite, thereby following the mass-action principle in epidemiology. Theoretical support for this finding is provided by an agent-based simulation model. The immediate host environment (cell volume) substantially affected parasite reproductive output and also interacted with the external herbicide exposed environment. On the contrary, changes in the immediate host environment through herbicide pre-exposure did not increase infection success, though it had subtle effects on zoospore development time and reproductive output. This study shows that both immediate host and external environment as well as their interaction have significant effects on parasite fitness. Disentangling these effects improves our understanding of the processes underlying parasite spread and disease dynamics.

  17. An Evaluation of Signal Annoyance for a Head-Mounted Tactile Display

    DTIC Science & Technology

    2015-03-01

    the burden, to Department of Defense , Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215... the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the ...be used on the finger, torso, and arm, and currently, vibrotactile signals are optimized for use on those areas. Thus, integrating BC

  18. The Effect of Parkinson's Disease on the Control of Multi-Segmental Coordination

    ERIC Educational Resources Information Center

    Bertram, C.P.; Lemay, M.; Stelmach, G.E.

    2005-01-01

    An experiment was designed to test whether or not Parkinson's disease (PD) patients were able to maintain endpoint kinematic patterns in a prehension task involving movement of the torso. Nine PD patients and nine healthy controls were asked to reach for and grasp a full cup of water that was either covered or uncovered and placed beyond the reach…

  19. A Laparoscopic Swine Model of Noncompressible Torso Hemorrhage

    DTIC Science & Technology

    2014-01-01

    Various porcine models of hemorrhage have been developed for civilian and military trauma research. However, the predominant contemporary models lack...significant predictors of mortality. CONCLUSION: This study describes a model of NCTH that reflects clinically relevant physiology in trauma and...uncontrolled hemorrhage. In addition, it quantitatively assesses the role of the swine contractile spleen in the described model. (J Trauma Acute Care Surg

  20. Comparative Assessment of Torso and Seat Mounted Restraint Systems using Manikins on the Horizontal Impulse Accelerator

    DTIC Science & Technology

    2017-11-01

    rearward rotation of the head towards the back or shoulder blades ). The y- axis of the head runs from right ear canal to the left ear canal with...PERSON (Monitor) a. REPORT Unclassified b. ABSTRACT Unclassified c . THIS PAGE Unclassified Chris Burneka 19b. TELEPHONE NUMBER...92 APPENDIX C . SAMPLE DATA SHEETS

  1. Kinematics of a Head-Neck Model Simulating Whiplash

    ERIC Educational Resources Information Center

    Colicchia, Giuseppe; Zollman, Dean; Wiesner, Hartmut; Sen, Ahmet Ilhan

    2008-01-01

    A whiplash event is a relative motion between the head and torso that occurs in rear-end automobile collisions. In particular, the large inertia of the head results in a horizontal translation relative to the thorax. This paper describes a simulation of the motion of the head and neck during a rear-end (whiplash) collision. A head-neck model that…

  2. Skvortsov and Kornienko with Matroshka-2 Kibo Hardware

    NASA Image and Video Library

    2010-05-04

    ISS023-E-031580 (4 May 2010) --- Russian cosmonauts Alexander Skvortsov (foreground) and Mikhail Kornienko, both Expedition 23 flight engineers, work with the European Matroshka-R Phantom experiment in the Kibo laboratory of the International Space Station. Matroshka, the name for the traditional Russian set of nestling dolls, is an antroph-amorphous model of a human torso designed for radiation studies.

  3. Skvortsov and Kornienko with Matroshka-2 Kibo Hardware

    NASA Image and Video Library

    2010-05-04

    ISS023-E-031597 (4 May 2010) --- Russian cosmonauts Alexander Skvortsov (left) and Mikhail Kornienko, both Expedition 23 flight engineers, work with the European Matroshka-R Phantom experiment in the Kibo laboratory of the International Space Station. Matroshka, the name for the traditional Russian set of nestling dolls, is an antroph-amorphous model of a human torso designed for radiation studies.

  4. Skvortsov and Kornienko with Matroshka-2 Kibo Hardware

    NASA Image and Video Library

    2010-05-04

    ISS023-E-031598 (4 May 2010) --- Russian cosmonauts Alexander Skvortsov (left) and Mikhail Kornienko, both Expedition 23 flight engineers, work with the European Matroshka-R Phantom experiment in the Kibo laboratory of the International Space Station. Matroshka, the name for the traditional Russian set of nestling dolls, is an antroph-amorphous model of a human torso designed for radiation studies.

  5. 49 CFR 572.154 - Thorax assembly and test procedure.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... test probe conforming to § 572.155(a) at 5.0 ±0.1m/s (16.5 ±0.3 ft/s) according to the test procedure in paragraph (c) of this section, the peak force, measured by the impact probe in accordance with... longitudinal centerline of the probe coincides with the dummy's midsagittal plane, is centered on the torso 196...

  6. 49 CFR 572.154 - Thorax assembly and test procedure.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... test probe conforming to § 572.155(a) at 5.0 ±0.1m/s (16.5 ±0.3 ft/s) according to the test procedure in paragraph (c) of this section, the peak force, measured by the impact probe in accordance with... longitudinal centerline of the probe coincides with the dummy's midsagittal plane, is centered on the torso 196...

  7. 49 CFR 572.154 - Thorax assembly and test procedure.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... test probe conforming to § 572.155(a) at 5.0 ±0.1m/s (16.5 ±0.3 ft/s) according to the test procedure in paragraph (c) of this section, the peak force, measured by the impact probe in accordance with... longitudinal centerline of the probe coincides with the dummy's midsagittal plane, is centered on the torso 196...

  8. 49 CFR 572.154 - Thorax assembly and test procedure.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... test probe conforming to § 572.155(a) at 5.0 ±0.1m/s (16.5 ±0.3 ft/s) according to the test procedure in paragraph (c) of this section, the peak force, measured by the impact probe in accordance with... longitudinal centerline of the probe coincides with the dummy's midsagittal plane, is centered on the torso 196...

  9. In Search of Dignity: One Family Caring for Their Child's Incontinence

    ERIC Educational Resources Information Center

    Coelho, Amy

    2009-01-01

    This article shares a story of a family with a child who has a spastic quadriplegia cerebral palsy, a form of cerebral palsy (CP) that affects all four limbs and torso with debilitating muscle dysfunction. It describes how the family cares for their child's incontinence. It also shares the experience of the child's mother, Kathy, who attributes…

  10. Improved Clothing for Firefighters

    NASA Technical Reports Server (NTRS)

    Abeles, F. J.

    1982-01-01

    Application of space technology should reduce incidence of injuries, heat exhaustion, and fatigue in firefighters. Using advanced materials and design concepts of aerospace technology, protective gear was fabricated and tested for the heat, face, torso, hand and foot. In tests, it was found that new gear protects better than conventional firefighter gear, weighs 40 percent less, and reduces wearer's energy expenditure by 25 percent.

  11. 76 FR 37025 - Make Inoperative Exemptions; Vehicle Modifications To Accommodate People With Disabilities, Side...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-24

    ... the seat. Many vehicles will depend on side impact air bag technology to meet all of the injury... installing side air bags in vehicle seats and/or door panels and side roof rails. The phase-in of the... expressed concern that: ``* * * torso side air bags are commonly installed in the outboard side of the OEM...

  12. 75 FR 59674 - Make Inoperative Exemptions; Vehicle Modifications To Accommodate People With Disabilities, Side...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-28

    ... that many vehicles will depend on side impact air bag technology to meet all of the injury criteria of... ``lead to the installation of new technologies, such as side curtain air bags and torso side air bags... is side air bag technology incorporated in the vehicle's roof rail (side air bag curtain), door, and...

  13. Kinesthetic Force Feedback and Belt Control for the Treadport Locomotion Interface.

    PubMed

    Hejrati, Babak; Crandall, Kyle L; Hollerbach, John M; Abbott, Jake J

    2015-01-01

    This paper describes an improved control system for the Treadport immersive locomotion interface, with results that generalize to any treadmill that utilizes an actuated tether to enable self-selected walking speed. A new belt controller is implemented to regulate the user's position; when combined with the user's own volition, this controller also enables the user to naturally self-select their walking speed as they would when walking over ground. A new kinesthetic-force-feedback controller is designed for the tether that applies forces to the user's torso. This new controller is derived based on maintaining the user's sense of balance during belt acceleration, rather than by rendering an inertial force as was done in our prior work. Based on the results of a human-subjects study, the improvements in both controllers significantly contribute to an improved perception of realistic walking on the Treadport. The improved control system uses intuitive dynamic-system and anatomical parameters and requires no ad hoc gain tuning. The control system simply requires three measurements to be made for a given user: the user's mass, the user's height, and the height of the tether attachment point on the user's torso.

  14. Computation of breast ptosis from 3D surface scans of the female torso

    PubMed Central

    Li, Danni; Cheong, Audrey; Reece, Gregory P.; Crosby, Melissa A.; Fingeret, Michelle C.; Merchant, Fatima A.

    2016-01-01

    Stereophotography is now finding a niche in clinical breast surgery, and several methods for quantitatively measuring breast morphology from 3D surface images have been developed. Breast ptosis (sagging of the breast), which refers to the extent by which the nipple is lower than the inframammary fold (the contour along which the inferior part of the breast attaches to the chest wall), is an important morphological parameter that is frequently used for assessing the outcome of breast surgery. This study presents a novel algorithm that utilizes three-dimensional (3D) features such as surface curvature and orientation for the assessment of breast ptosis from 3D scans of the female torso. The performance of the computational approach proposed was compared against the consensus of manual ptosis ratings by nine plastic surgeons, and that of current 2D photogrammetric methods. Compared to the 2D methods, the average accuracy for 3D features was ~13% higher, with an increase in precision, recall, and F-score of 37%, 29%, and 33%, respectively. The computational approach proposed provides an improved and unbiased objective method for rating ptosis when compared to qualitative visualization by observers, and distance based 2D photogrammetry approaches. PMID:27643463

  15. Mitigation of lung injury after accidental exposure to radiation.

    PubMed

    Mahmood, J; Jelveh, S; Calveley, V; Zaidi, A; Doctrow, S R; Hill, R P

    2011-12-01

    There is a serious need to develop effective mitigators against accidental radiation exposures. In radiation accidents, many people may receive nonuniform whole-body or partial-body irradiation. The lung is one of the more radiosensitive organs, demonstrating pneumonitis and fibrosis that are believed to develop at least partially because of radiation-induced chronic inflammation. Here we addressed the crucial questions of how damage to the lung can be mitigated and whether the response is affected by irradiation to the rest of the body. We examined the widely used dietary supplement genistein given at two dietary levels (750 or 3750 mg/kg) to Fischer rats irradiated with 12 Gy to the lung or 8 Gy to the lung + 4 Gy to the whole body excluding the head and tail (whole torso). We found that genistein had promising mitigating effects on oxidative damage, pneumonitis and fibrosis even at late times (36 weeks) when drug treatment was initiated 1 week after irradiation and stopped at 28 weeks postirradiation. The higher dose of genistein showed no greater beneficial effect. Combined lung and whole-torso irradiation caused more lung-related severe morbidity resulting in euthanasia of the animals than lung irradiation alone.

  16. Fluid resuscitation of the trauma patient: How much is enough?

    PubMed Central

    Hamilton, Stewart M.; Breakey, Pat

    1996-01-01

    Patient management in the prehospital resuscitative phase after trauma is vitally important to the outcome. Early definitive care remains the essential element in improving morbidity and mortality. In Canada, where a large proportion of trauma occurs at sites distant from a trauma centre, the prehospital resuscitative phase is long and has even greater potential to affect outcome. Conventional teaching about the end points of resuscitation has promoted the concept of normalization of hemodynamic parameters with maintenance of end-organ perfusion, as measured by the hourly urine output. Recent work in patients with a closed head injury and in patients with penetrating torso trauma challenge the notion that trauma patients are homogeneous with respect to these end points. In the Canadian setting of blunt injury, where a closed head injury is usually suspected and often present, the evidence from clinical studies suggests that an aggressive approach to maintaining blood pressure is warranted. In penetrating torso injury in an urban setting, there is evidence to suggest that delaying resuscitation until hemorrhage is controlled is beneficial. More Canadian clinical trials are required in this area. In the meantime, the priorities of resuscitation must be carefully assessed for each patient and pattern of injury. PMID:8599784

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ovard R. Perry; David L. Georgeson

    This report describes the April 2011 calibration of the Accuscan II HpGe In Vivo system for high energy lung counting. The source used for the calibration was a NIST traceable lung set manufactured at the University of Cincinnati UCLL43AMEU & UCSL43AMEU containing Am-241 and Eu-152 with energies from 26 keV to 1408 keV. The lung set was used in conjunction with a Realistic Torso phantom. The phantom was placed on the RMC II counting table (with pins removed) between the v-ridges on the backwall of the Accuscan II counter. The top of the detector housing was positioned perpendicular to themore » junction of the phantom clavicle with the sternum. This position places the approximate center line of the detector housing with the center of the lungs. The energy and efficiency calibrations were performed using a Realistic Torso phantom (Appendix I) and the University of Cincinnati lung set. This report includes an overview introduction and records for the energy/FWHM and efficiency calibration including performance verification and validation counting. The Accuscan II system was successfully calibrated for high energy lung counting and verified in accordance with ANSI/HPS N13.30-1996 criteria.« less

  18. Realistic Analytical Polyhedral MRI Phantoms

    PubMed Central

    Ngo, Tri M.; Fung, George S. K.; Han, Shuo; Chen, Min; Prince, Jerry L.; Tsui, Benjamin M. W.; McVeigh, Elliot R.; Herzka, Daniel A.

    2015-01-01

    Purpose Analytical phantoms have closed form Fourier transform expressions and are used to simulate MRI acquisitions. Existing 3D analytical phantoms are unable to accurately model shapes of biomedical interest. It is demonstrated that polyhedral analytical phantoms have closed form Fourier transform expressions and can accurately represent 3D biomedical shapes. Theory The derivations of the Fourier transform of a polygon and polyhedron are presented. Methods The Fourier transform of a polyhedron was implemented and its accuracy in representing faceted and smooth surfaces was characterized. Realistic anthropomorphic polyhedral brain and torso phantoms were constructed and their use in simulated 3D/2D MRI acquisitions was described. Results Using polyhedra, the Fourier transform of faceted shapes can be computed to within machine precision. Smooth surfaces can be approximated with increasing accuracy by increasing the number of facets in the polyhedron; the additional accumulated numerical imprecision of the Fourier transform of polyhedra with many faces remained small. Simulations of 3D/2D brain and 2D torso cine acquisitions produced realistic reconstructions free of high frequency edge aliasing as compared to equivalent voxelized/rasterized phantoms. Conclusion Analytical polyhedral phantoms are easy to construct and can accurately simulate shapes of biomedical interest. PMID:26479724

  19. Men, muscles, and body image: comparisons of competitive bodybuilders, weight trainers, and athletically active controls

    PubMed Central

    Pickett, T; Lewis, R; Cash, T; Pope, H

    2005-01-01

    Objectives: To investigate body image and psychosocial adjustment among competitive bodybuilders, non-competitive weight trainers, and athletically active men. Methods: Participants were 40 men in each of the three groups who were assessed on body composition and multiple facets of body image evaluation, investment and anxiety, eating attitudes, and social self esteem. Results: Relative to the other two groups, competitive bodybuilders had greater body mass due to fat-free body mass. Although groups did not differ in their situational body image discomfort, competitive bodybuilders and weight trainers had a more positive global appearance evaluation and were more psychologically invested in their physical appearance. Compared with active controls, men in both weightlifting groups were more satisfied with their upper torso and muscle tone. Competitive bodybuilders reported more mid torso satisfaction than the other two groups. Competitive bodybuilders also wished to be significantly heavier than controls did and reported higher social self esteem but greater eating disturbance. Conclusions: The findings suggest that competitive bodybuilders as a group are not more "muscle dysmorphic" than either non-competitive weight trainers or physically active men who do not train with weights. PMID:15793091

  20. Transfer of mechanical energy during the shot put.

    PubMed

    Błażkiewicz, Michalina; Łysoń, Barbara; Chmielewski, Adam; Wit, Andrzej

    2016-09-01

    The aim of this study was to analyse transfer of mechanical energy between body segments during the glide shot put. A group of eight elite throwers from the Polish National Team was analysed in the study. Motion analysis of each throw was recorded using an optoelectronic Vicon system composed of nine infrared camcorders and Kistler force plates. The power and energy were computed for the phase of final acceleration of the glide shot put. The data were normalized with respect to time using the algorithm of the fifth order spline and their values were interpolated with respect to the percentage of total time, assuming that the time of the final weight acceleration movement was different for each putter. Statistically significant transfer was found in the study group between the following segments: Right Knee - Right Hip (p = 0.0035), Left Hip - Torso (p = 0.0201), Torso - Right Shoulder (p = 0.0122) and Right Elbow - Right Wrist (p = 0.0001). Furthermore, the results of cluster analysis showed that the kinetic chain used during the final shot acceleration movement had two different models. Differences between the groups were revealed mainly in the energy generated by the hips and trunk.

Top