Verification of a Viscous Computational Aeroacoustics Code using External Verification Analysis
NASA Technical Reports Server (NTRS)
Ingraham, Daniel; Hixon, Ray
2015-01-01
The External Verification Analysis approach to code verification is extended to solve the three-dimensional Navier-Stokes equations with constant properties, and is used to verify a high-order computational aeroacoustics (CAA) code. After a brief review of the relevant literature, the details of the EVA approach are presented and compared to the similar Method of Manufactured Solutions (MMS). Pseudocode representations of EVA's algorithms are included, along with the recurrence relations needed to construct the EVA solution. The code verification results show that EVA was able to convincingly verify a high-order, viscous CAA code without the addition of MMS-style source terms, or any other modifications to the code.
Verification of a Viscous Computational Aeroacoustics Code Using External Verification Analysis
NASA Technical Reports Server (NTRS)
Ingraham, Daniel; Hixon, Ray
2015-01-01
The External Verification Analysis approach to code verification is extended to solve the three-dimensional Navier-Stokes equations with constant properties, and is used to verify a high-order computational aeroacoustics (CAA) code. After a brief review of the relevant literature, the details of the EVA approach are presented and compared to the similar Method of Manufactured Solutions (MMS). Pseudocode representations of EVA's algorithms are included, along with the recurrence relations needed to construct the EVA solution. The code verification results show that EVA was able to convincingly verify a high-order, viscous CAA code without the addition of MMS-style source terms, or any other modifications to the code.
Implementation of Precision Verification Solvents on the External Tank
NASA Technical Reports Server (NTRS)
Campbell, M.
1998-01-01
This paper presents the Implementation of Precision Verification Solvents on the External Tank. The topics include: 1) Background; 2) Solvent Usages; 3) TCE (Trichloroethylene) Reduction; 4) Solvent Replacement Studies; 5) Implementation; 6) Problems Occuring During Implementation; and 7) Future Work. This paper is presented in viewgraph form.
NASA Astrophysics Data System (ADS)
Chen, Peng; Liu, Yuwei; Gao, Bingkun; Jiang, Chunlei
2018-03-01
A semiconductor laser employed with two-external-cavity feedback structure for laser self-mixing interference (SMI) phenomenon is investigated and analyzed. The SMI model with two directions based on F-P cavity is deduced, and numerical simulation and experimental verification were conducted. Experimental results show that the SMI with the structure of two-external-cavity feedback under weak light feedback is similar to the sum of two SMIs.
Jornet, Núria; Carrasco, Pablo; Beltrán, Mercè; Calvo, Juan Francisco; Escudé, Lluís; Hernández, Victor; Quera, Jaume; Sáez, Jordi
2014-09-01
We performed a multicentre intercomparison of IMRT optimisation and dose planning and IMRT pre-treatment verification methods and results. The aims were to check consistency between dose plans and to validate whether in-house pre-treatment verification results agreed with those of an external audit. Participating centres used two mock cases (prostate and head and neck) for the intercomparison and audit. Compliance to dosimetric goals and total number of MU per plan were collected. A simple quality index to compare the different plans was proposed. We compared gamma index pass rates using the centre's equipment and methodology to those of an external audit. While for the prostate case, all centres fulfilled the dosimetric goals and plan quality was homogeneous, that was not the case for the head and neck case. The number of MU did not correlate with the plan quality index. Pre-treatment verifications results of the external audit did not agree with those of the in-house measurements for two centres: being within tolerance for in-house measurements and unacceptable for the audit or the other way round. Although all plans fulfilled dosimetric constraints, plan quality is highly dependent on the planner expertise. External audits are an excellent tool to detect errors in IMRT implementation and cannot be replaced by intercomparison using results obtained by centres. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Multi-centre audit of VMAT planning and pre-treatment verification.
Jurado-Bruggeman, Diego; Hernández, Victor; Sáez, Jordi; Navarro, David; Pino, Francisco; Martínez, Tatiana; Alayrach, Maria-Elena; Ailleres, Norbert; Melero, Alejandro; Jornet, Núria
2017-08-01
We performed a multi-centre intercomparison of VMAT dose planning and pre-treatment verification. The aims were to analyse the dose plans in terms of dosimetric quality and deliverability, and to validate whether in-house pre-treatment verification results agreed with those of an external audit. The nine participating centres encompassed different machines, equipment, and methodologies. Two mock cases (prostate and head and neck) were planned using one and two arcs. A plan quality index was defined to compare the plans and different complexity indices were calculated to check their deliverability. We compared gamma index pass rates using the centre's equipment and methodology to those of an external audit (global 3D gamma, absolute dose differences, 10% of maximum dose threshold). Log-file analysis was performed to look for delivery errors. All centres fulfilled the dosimetric goals but plan quality and delivery complexity were heterogeneous and uncorrelated, depending on the manufacturer and the planner's methodology. Pre-treatment verifications results were within tolerance in all cases for gamma 3%-3mm evaluation. Nevertheless, differences between the external audit and in-house measurements arose due to different equipment or methodology, especially for 2%-2mm criteria with differences up to 20%. No correlation was found between complexity indices and verification results amongst centres. All plans fulfilled dosimetric constraints, but plan quality and complexity did not correlate and were strongly dependent on the planner and the vendor. In-house measurements cannot completely replace external audits for credentialing. Copyright © 2017 Elsevier B.V. All rights reserved.
The Mars Science Laboratory Organic Check Material
NASA Astrophysics Data System (ADS)
Conrad, Pamela G.; Eigenbrode, Jennifer L.; Von der Heydt, Max O.; Mogensen, Claus T.; Canham, John; Harpold, Dan N.; Johnson, Joel; Errigo, Therese; Glavin, Daniel P.; Mahaffy, Paul R.
2012-09-01
Mars Science Laboratory's Curiosity rover carries a set of five external verification standards in hermetically sealed containers that can be sampled as would be a Martian rock, by drilling and then portioning into the solid sample inlet of the Sample Analysis at Mars (SAM) suite. Each organic check material (OCM) canister contains a porous ceramic solid, which has been doped with a fluorinated hydrocarbon marker that can be detected by SAM. The purpose of the OCM is to serve as a verification tool for the organic cleanliness of those parts of the sample chain that cannot be cleaned other than by dilution, i.e., repeated sampling of Martian rock. SAM possesses internal calibrants for verification of both its performance and its internal cleanliness, and the OCM is not used for that purpose. Each OCM unit is designed for one use only, and the choice to do so will be made by the project science group (PSG).
78 FR 1162 - Cardiovascular Devices; Reclassification of External Cardiac Compressor
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-08
... safety and electromagnetic compatibility; For devices containing software, software verification... electromagnetic compatibility; For devices containing software, software verification, validation, and hazard... electrical components, appropriate analysis and testing must validate electrical safety and electromagnetic...
The Internal Control System and Control Programs: A Reference Guide
1990-06-01
multilocation audits . [Ref. 27:Ch. 8, p. 4] 3. Verification Staqe The actual audit field work occurs during this phase. The audit team provides an entrance...number) ;E, GUO.)P SuB GROUP Internal Control; Internal Control System; Audits ; Reviews; Ccamand Evaluation Program; EconnTy & Efficiency Reviews...general overview of the inter- nal control system and discusses the various external and internal audits , inspections, reviews and investiaative
40 CFR 1065.307 - Linearity verification.
Code of Federal Regulations, 2012 CFR
2012-07-01
... meter at different flow rates. Use a gravimetric reference measurement (such as a scale, balance, or... nitrogen. Select gas divisions that you typically use. Use a selected gas division as the measured value.... For linearity verification for gravimetric PM balances, use external calibration weights that that...
40 CFR 1065.307 - Linearity verification.
Code of Federal Regulations, 2013 CFR
2013-07-01
... meter at different flow rates. Use a gravimetric reference measurement (such as a scale, balance, or... nitrogen. Select gas divisions that you typically use. Use a selected gas division as the measured value.... For linearity verification for gravimetric PM balances, use external calibration weights that that...
40 CFR 1065.307 - Linearity verification.
Code of Federal Regulations, 2014 CFR
2014-07-01
... measurement (such as a scale, balance, or mass comparator) at the inlet to the fuel-measurement system. Use a... nitrogen. Select gas divisions that you typically use. Use a selected gas division as the measured value.... (9) Mass. For linearity verification for gravimetric PM balances, use external calibration weights...
40 CFR 1065.307 - Linearity verification.
Code of Federal Regulations, 2011 CFR
2011-07-01
... different flow rates. Use a gravimetric reference measurement (such as a scale, balance, or mass comparator... the gas-division system to divide the span gas with purified air or nitrogen. Select gas divisions... verification for gravimetric PM balances, use external calibration weights that that meet the requirements in...
Verification across Multiple Identities: The Role of Status
ERIC Educational Resources Information Center
Stets, Jan E.; Harrod, Michael M.
2004-01-01
We explore how the external social structure influences internal self-processes by examining whether one's status in the social structure influences one's ability to self-verify across multiple identities. We also examine whether greater verification is related to positive self-feelings (higher self-esteem and mastery) in a stable manner, across…
International Space Station External Contamination Status
NASA Technical Reports Server (NTRS)
Mikatarian, Ron; Soares, Carlos
2000-01-01
PResentation slides examine external contamination requirements; International Space Station (ISS) external contamination sources; ISS external contamination sensitive surfaces; external contamination control; external contamination control for pre-launch verification; flight experiments and observations; the Space Shuttle Orbiter waste water dump, materials outgassing, active vacuum vents; example of molecular column density profile, modeling and analysis tools; sources of outgassing induced contamination analyzed to date, quiescent sources, observations on optical degradation due to induced external contamination in LEO; examples of typical contaminant and depth profiles; and status of the ISS system, material outgassing, thruster plumes, and optical degradation.
Verification of EPA's " Preliminary remediation goals for radionuclides" (PRG) electronic calculator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stagich, B. H.
The U.S. Environmental Protection Agency (EPA) requested an external, independent verification study of their “Preliminary Remediation Goals for Radionuclides” (PRG) electronic calculator. The calculator provides information on establishing PRGs for radionuclides at Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) sites with radioactive contamination (Verification Study Charge, Background). These risk-based PRGs set concentration limits using carcinogenic toxicity values under specific exposure conditions (PRG User’s Guide, Section 1). The purpose of this verification study is to ascertain that the computer codes has no inherit numerical problems with obtaining solutions as well as to ensure that the equations are programmed correctly.
Wu, R H; Lin, R; Li, H; Xiao, Z W; Rao, H B; Luo, W H; Guo, G; Huang, K; Zhang, X G; Lang, Z J
2005-01-01
The metabolite ratios had been employed in the field of MR spectroscopy (MRS) for a long period. The main drawback of metabolite ratio is that ratio results are not comparable with absolute metabolite concentration in vivo. The purpose of this study was to examine the accuracy of noninvasive quantification of brain N-acetylaspartate (NAA) concentrations using previously reported MR external standard method. Eight swine were scanned on a GE 1.5 T scanner with a standard head coil. The external standard method was utilized with a sphere filled with NAA, GABA, glutamine, glutamate, creatine, choline chloride, and myo-inositol. The position resolved spectroscopy (PRESS) sequence was used with TE=135 msec, TR=1500 msec, and 128 scan averages. The analysis of MRS was done with SAGE/IDL program. In vivo NAA concentration was obtained using the equation S=N * e(-TE/T2) * [1-e(-TR/T1). In vitro NAA concentration was measured by high performance liquid chromatography (HPLC). In the MRS group, the mean concentration of NAA was 10.03 plusmn 0.74 mmol/kg. In the HPLC group, the mean concentration of NAA was 9.22 plusmn 0.55 mmol/kg. There was no significant difference between the two groups (p = 0.46). However, slightly higher value was observed in the MRS group (7/8 swine), compared with HPLC group. The range of differences was between 0.02~2.05 mmol/kg. MRS external reference method could be more accurate than internal reference method. 1H MRS does not distinguish between N-acetyl resonance frequencies and other N-acetylated amino acids.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-26
... listings to reflect certain verification findings. Also, in February 2012, the petitioner and the... two interior storage compartments accessible through one or more separate external doors or drawers or... external door or drawer is either a refrigerator compartment or convertible compartment, but is not a...
The effect of mystery shopper reports on age verification for tobacco purchases.
Krevor, Brad S; Ponicki, William R; Grube, Joel W; DeJong, William
2011-09-01
Mystery shops involving attempted tobacco purchases by young buyers have been implemented in order to monitor retail stores' performance in refusing underage sales. Anecdotal evidence suggests that mystery shop visits with immediate feedback to store personnel can improve age verification. This study investigated the effect of monthly and twice-monthly mystery shop reports on age verification. Mystery shoppers visited 45 Walgreens stores 20 times. The stores were randomly assigned to 1 of 3 conditions. Control group stores received no feedback, whereas 2 treatment groups received feedback communications on every visit (twice monthly) or on every second visit (monthly) after baseline. Logit regression models tested whether each treatment group improved verification rates relative to the control group. Postbaseline verification rates were higher in both treatment groups than in the control group, but only the stores receiving monthly communications had a significantly greater improvement compared with the control group stores. Verification rates increased significantly during the study period for all 3 groups, with delayed improvement among control group stores. Communication between managers regarding the mystery shop program may account for the delayed age-verification improvements observed in the control group stores. Encouraging interstore communication might extend the benefits of mystery shop programs beyond those stores that receive this intervention. Copyright © Taylor & Francis Group, LLC
External tank aerothermal design criteria verification, volume 2
NASA Technical Reports Server (NTRS)
Crain, William K.; Frost, Cynthia; Warmbrod, John
1990-01-01
The objective of the study was to produce an independent set of ascent environments which would serve as a check on the Rockwell International (RI) IVBC-3 environments and provide an independent reevaluation of the thermal design criteria for the External Tank (ET). Given here are the plotted timewise environments comparing REMTECH results to the RI IVBC results.
The Effect of Mystery Shopper Reports on Age Verification for Tobacco Purchases
KREVOR, BRAD S.; PONICKI, WILLIAM R.; GRUBE, JOEL W.; DeJONG, WILLIAM
2011-01-01
Mystery shops (MS) involving attempted tobacco purchases by young buyers have been employed to monitor retail stores’ performance in refusing underage sales. Anecdotal evidence suggests that MS visits with immediate feedback to store personnel can improve age verification. This study investigated the impact of monthly and twice-monthly MS reports on age verification. Forty-five Walgreens stores were each visited 20 times by mystery shoppers. The stores were randomly assigned to one of three conditions. Control group stores received no feedback, whereas two treatment groups received feedback communications every visit (twice monthly) or every second visit (monthly) after baseline. Logit regression models tested whether each treatment group improved verification rates relative to the control group. Post-baseline verification rates were higher in both treatment groups than in the control group, but only the stores receiving monthly communications had a significantly greater improvement than control group stores. Verification rates increased significantly during the study period for all three groups, with delayed improvement among control group stores. Communication between managers regarding the MS program may account for the delayed age-verification improvements observed in the control group stores. Encouraging inter-store communication might extend the benefits of MS programs beyond those stores that receive this intervention. PMID:21541874
Swann, William B; Kwan, Virginia S Y; Polzer, Jeffrey T; Milton, Laurie P
2003-11-01
A longitudinal study examined the interplay of identity negotiation processes and diversity in small groups of master's of business administration (MBA) students. When perceivers formed relatively positive impressions of other group members, higher diversity predicted more individuation of targets. When perceivers formed relatively neutral impressions of other group members, however, higher diversity predicted less individuation of targets. Individuation at the outset of the semester predicted self-verification effects several weeks later, and self-verification, in turn, predicted group identification and creative task performance. The authors conclude that contrary to self-categorization theory, fostering individuation and self-verification in diverse groups may maximize group identification and productivity.
Coherent inductive communications link for biomedical applications
NASA Technical Reports Server (NTRS)
Hogrefe, Arthur F. (Inventor); Radford, Wade E. (Inventor)
1985-01-01
A two-way coherent inductive communications link between an external transceiver and an internal transceiver located in a biologically implanted programmable medical device. Digitally formatted command data and programming data is transmitted to the implanted medical device by frequency shift keying the inductive communications link. Internal transceiver is powered by the inductive field between internal and external transceivers. Digitally formatted data is transmitted to external transceiver by internal transceiver amplitude modulating inductive field. Immediate verification of the establishment of a reliable communications link is provided by determining existence of frequency lock and bit phase lock between internal and external transceivers.
Active Interrogation for Spent Fuel
DOE Office of Scientific and Technical Information (OSTI.GOV)
Swinhoe, Martyn Thomas; Dougan, Arden
2015-11-05
The DDA instrument for nuclear safeguards is a fast, non-destructive assay, active neutron interrogation technique using an external 14 MeV DT neutron generator for characterization and verification of spent nuclear fuel assemblies.
Current status of verification practices in clinical biochemistry in Spain.
Gómez-Rioja, Rubén; Alvarez, Virtudes; Ventura, Montserrat; Alsina, M Jesús; Barba, Núria; Cortés, Mariano; Llopis, María Antonia; Martínez, Cecilia; Ibarz, Mercè
2013-09-01
Verification uses logical algorithms to detect potential errors before laboratory results are released to the clinician. Even though verification is one of the main processes in all laboratories, there is a lack of standardization mainly in the algorithms used and the criteria and verification limits applied. A survey in clinical laboratories in Spain was conducted in order to assess the verification process, particularly the use of autoverification. Questionnaires were sent to the laboratories involved in the External Quality Assurance Program organized by the Spanish Society of Clinical Biochemistry and Molecular Pathology. Seven common biochemical parameters were included (glucose, cholesterol, triglycerides, creatinine, potassium, calcium, and alanine aminotransferase). Completed questionnaires were received from 85 laboratories. Nearly all the laboratories reported using the following seven verification criteria: internal quality control, instrument warnings, sample deterioration, reference limits, clinical data, concordance between parameters, and verification of results. The use of all verification criteria varied according to the type of verification (automatic, technical, or medical). Verification limits for these parameters are similar to biological reference ranges. Delta Check was used in 24% of laboratories. Most laboratories (64%) reported using autoverification systems. Autoverification use was related to laboratory size, ownership, and type of laboratory information system, but amount of use (percentage of test autoverified) was not related to laboratory size. A total of 36% of Spanish laboratories do not use autoverification, despite the general implementation of laboratory information systems, most of them, with autoverification ability. Criteria and rules for seven routine biochemical tests were obtained.
A Mechanism of Modeling and Verification for SaaS Customization Based on TLA
NASA Astrophysics Data System (ADS)
Luan, Shuai; Shi, Yuliang; Wang, Haiyang
With the gradually mature of SOA and the rapid development of Internet, SaaS has become a popular software service mode. The customized action of SaaS is usually subject to internal and external dependency relationships. This paper first introduces a method for modeling customization process based on Temporal Logic of Actions, and then proposes a verification algorithm to assure that each step in customization will not cause unpredictable influence on system and follow the related rules defined by SaaS provider.
Dosimetry for audit and clinical trials: challenges and requirements
NASA Astrophysics Data System (ADS)
Kron, T.; Haworth, A.; Williams, I.
2013-06-01
Many important dosimetry audit networks for radiotherapy have their roots in clinical trial quality assurance (QA). In both scenarios it is essential to test two issues: does the treatment plan conform with the clinical requirements and is the plan a reasonable representation of what is actually delivered to a patient throughout their course of treatment. Part of a sound quality program would be an external audit of these issues with verification of the equivalence of plan and treatment typically referred to as a dosimetry audit. The increasing complexity of radiotherapy planning and delivery makes audits challenging. While verification of absolute dose delivered at a reference point was the standard of external dosimetry audits two decades ago this is often deemed inadequate for verification of treatment approaches such as Intensity Modulated Radiation Therapy (IMRT) and Volumetric Modulated Arc Therapy (VMAT). As such, most dosimetry audit networks have successfully introduced more complex tests of dose delivery using anthropomorphic phantoms that can be imaged, planned and treated as a patient would. The new challenge is to adapt this approach to ever more diversified radiotherapy procedures with image guided/adaptive radiotherapy, motion management and brachytherapy being the focus of current research.
Supersonic gas-liquid cleaning system
NASA Technical Reports Server (NTRS)
Caimi, Raoul E. B.; Thaxton, Eric A.
1994-01-01
A system to perform cleaning and cleanliness verification is being developed to replace solvent flush methods using CFC 113 for fluid system components. The system is designed for two purposes: internal and external cleaning and verification. External cleaning is performed with the nozzle mounted at the end of a wand similar to a conventional pressure washer. Internal cleaning is performed with a variety of fixtures designed for specific applications. Internal cleaning includes tubes, pipes, flex hoses, and active fluid components such as valves and regulators. The system uses gas-liquid supersonic nozzles to generate high impingement velocities at the surface of the object to be cleaned. Compressed air or any inert gas may be used to provide the conveying medium for the liquid. The converging-diverging nozzles accelerate the gas-liquid mixture to supersonic velocities. The liquid being accelerated may be any solvent including water. This system may be used commercially to replace CFC and other solvent cleaning methods widely used to remove dust, dirt, flux, and lubricants. In addition, cleanliness verification can be performed without the solvents which are typically involved. This paper will present the technical details of the system, the results achieved during testing at KSC, and future applications for this system.
Supersonic gas-liquid cleaning system
NASA Astrophysics Data System (ADS)
Caimi, Raoul E. B.; Thaxton, Eric A.
1994-02-01
A system to perform cleaning and cleanliness verification is being developed to replace solvent flush methods using CFC 113 for fluid system components. The system is designed for two purposes: internal and external cleaning and verification. External cleaning is performed with the nozzle mounted at the end of a wand similar to a conventional pressure washer. Internal cleaning is performed with a variety of fixtures designed for specific applications. Internal cleaning includes tubes, pipes, flex hoses, and active fluid components such as valves and regulators. The system uses gas-liquid supersonic nozzles to generate high impingement velocities at the surface of the object to be cleaned. Compressed air or any inert gas may be used to provide the conveying medium for the liquid. The converging-diverging nozzles accelerate the gas-liquid mixture to supersonic velocities. The liquid being accelerated may be any solvent including water. This system may be used commercially to replace CFC and other solvent cleaning methods widely used to remove dust, dirt, flux, and lubricants. In addition, cleanliness verification can be performed without the solvents which are typically involved. This paper will present the technical details of the system, the results achieved during testing at KSC, and future applications for this system.
Positron emission imaging device and method of using the same
Bingham, Philip R.; Mullens, James Allen
2013-01-15
An imaging system and method of imaging are disclosed. The imaging system can include an external radiation source producing pairs of substantially simultaneous radiation emissions of a picturization emission and a verification emissions at an emission angle. The imaging system can also include a plurality of picturization sensors and at least one verification sensor for detecting the picturization and verification emissions, respectively. The imaging system also includes an object stage is arranged such that a picturization emission can pass through an object supported on said object stage before being detected by one of said plurality of picturization sensors. A coincidence system and a reconstruction system can also be included. The coincidence can receive information from the picturization and verification sensors and determine whether a detected picturization emission is direct radiation or scattered radiation. The reconstruction system can produce a multi-dimensional representation of an object imaged with the imaging system.
Progress on an external occulter testbed at flight Fresnel numbers
NASA Astrophysics Data System (ADS)
Kim, Yunjong; Sirbu, Dan; Galvin, Michael; Kasdin, N. Jeremy; Vanderbei, Robert J.
2016-01-01
An external occulter is a spacecraft flown along the line-of-sight of a space telescope to suppress starlight and enable high-contrast direct imaging of exoplanets. Laboratory verification of occulter designs is necessary to validate the optical models used to design and predict occulter performance. At Princeton, we have designed and built a testbed that allows verification of scaled occulter designs whose suppressed shadow is mathematically identical to that of space occulters. The occulter testbed uses 78 m optical propagation distance to realize the flight Fresnel numbers. We will use an etched silicon mask as the occulter. The occulter is illuminated by a diverging laser beam to reduce the aberrations from the optics before the occulter. Here, we present first light result of a sample design operating at a flight Fresnel number and the mechanical design of the testbed. We compare the experimental results with simulations that predict the ultimate contrast performance.
Integrated Medical Model (IMM) Project Verification, Validation, and Credibility (VVandC)
NASA Technical Reports Server (NTRS)
Walton, M.; Boley, L.; Keenan, L.; Kerstman, E.; Shah, R.; Young, M.; Saile, L.; Garcia, Y.; Meyers, J.; Reyes, D.
2015-01-01
The Integrated Medical Model (IMM) Project supports end user requests by employing the Integrated Medical Evidence Database (iMED) and IMM tools as well as subject matter expertise within the Project. The iMED houses data used by the IMM. The IMM is designed to forecast relative changes for a specified set of crew health and mission success risk metrics by using a probabilistic model based on historical data, cohort data, and subject matter expert opinion. A stochastic approach is taken because deterministic results would not appropriately reflect the uncertainty in the IMM inputs. Once the IMM was conceptualized, a plan was needed to rigorously assess input information, framework and code, and output results of the IMM, and ensure that end user requests and requirements were considered during all stages of model development and implementation, as well as lay the foundation for external review and application. METHODS: In 2008, the Project team developed a comprehensive verification and validation (VV) plan, which specified internal and external review criteria encompassing 1) verification of data and IMM structure to ensure proper implementation of the IMM, 2) several validation techniques to confirm that the simulation capability of the IMM appropriately represents occurrences and consequences of medical conditions during space missions, and 3) credibility processes to develop user confidence in the information derived from the IMM. When the NASA-STD-7009 (7009) [1] was published, the Project team updated their verification, validation, and credibility (VVC) project plan to meet 7009 requirements and include 7009 tools in reporting VVC status of the IMM. Construction of these tools included meeting documentation and evidence requirements sufficient to meet external review success criteria. RESULTS: IMM Project VVC updates are compiled recurrently and include updates to the 7009 Compliance and Credibility matrices. Reporting tools have evolved over the lifetime of the IMM Project to better communicate VVC status. This has included refining original 7009 methodology with augmentation from the HRP NASA-STD-7009 Guidance Document working group and the NASA-HDBK-7009 [2]. End user requests and requirements are being satisfied as evidenced by ISS Program acceptance of IMM risk forecasts, transition to an operational model and simulation tool, and completion of service requests from a broad end user consortium including operations, science and technology planning, and exploration planning. IMM v4.0 is slated for operational release in the FY015 and current VVC assessments illustrate the expected VVC status prior to the completion of customer lead external review efforts. CONCLUSIONS: The VVC approach established by the IMM Project of incorporating Project-specific recommended practices and guidelines for implementing the 7009 requirements is comprehensive and includes the involvement of end users at every stage in IMM evolution. Methods and techniques used to quantify the VVC status of the IMM Project represented a critical communication tool in providing clear and concise suitability assessments to IMM customers. These processes have not only received approval from the local NASA community but have also garnered recognition by other federal agencies seeking to develop similar guidelines in the medical modeling community.
Self-verification motives at the collective level of self-definition.
Chen, Serena; Chen, Karen Y; Shaw, Lindsay
2004-01-01
Three studies examined self-verification motives in relation to collective aspects of the self. Several moderators of collective self-verification were also examined--namely, the certainty with which collective self-views are held, the nature of one's ties to a source of self-verification, the salience of the collective self, and the importance of group identification. Evidence for collective self-verification emerged across all studies, particularly when collective self-views were held with high certainty (Studies 1 and 2), perceivers were somehow tied to the source of self-verification (Study 1), the collective self was salient (Study 2), and group identification was important (Study 3). To the authors' knowledge, these studies are the first to examine self-verification at the collective level of self-definition. The parallel and distinct ways in which self-verification processes may operate at different levels of self-definition are discussed.
NASA GSFC Mechanical Engineering Latest Inputs for Verification Standards (GEVS) Updates
NASA Technical Reports Server (NTRS)
Kaufman, Daniel
2003-01-01
This viewgraph presentation provides information on quality control standards in mechanical engineering. The presentation addresses safety, structural loads, nonmetallic composite structural elements, bonded structural joints, externally induced shock, random vibration, acoustic tests, and mechanical function.
An Optimized Online Verification Imaging Procedure for External Beam Partial Breast Irradiation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Willis, David J., E-mail: David.Willis@petermac.or; Royal Melbourne Institute of Technology University, Melbourne, Victoria; Kron, Tomas
2011-07-01
The purpose of this study was to evaluate the capabilities of a kilovoltage (kV) on-board imager (OBI)-equipped linear accelerator in the setting of on-line verification imaging for external-beam partial breast irradiation. Available imaging techniques were optimized and assessed for image quality using a modified anthropomorphic phantom. Imaging dose was also assessed. Imaging techniques were assessed for physical clearance between patient and treatment machine using a volunteer. Nonorthogonal kV image pairs were identified as optimal in terms of image quality, clearance, and dose. After institutional review board approval, this approach was used for 17 patients receiving accelerated partial breast irradiation. Imagingmore » was performed before every fraction verification with online correction of setup deviations >5 mm (total image sessions = 170). Treatment staff rated risk of collision and visibility of tumor bed surgical clips where present. Image session duration and detected setup deviations were recorded. For all cases, both image projections (n = 34) had low collision risk. Surgical clips were rated as well as visualized in all cases where they were present (n = 5). The average imaging session time was 6 min, 16 sec, and a reduction in duration was observed as staff became familiar with the technique. Setup deviations of up to 1.3 cm were detected before treatment and subsequently confirmed offline. Nonorthogonal kV image pairs allowed effective and efficient online verification for partial breast irradiation. It has yet to be tested in a multicenter study to determine whether it is dependent on skilled treatment staff.« less
Gómez, Angel; Seyle, D Conor; Huici, Carmen; Swann, William B
2009-12-01
Recent research has demonstrated self-verification strivings in groups, such that people strive to verify collective identities, which are personal self-views (e.g., "sensitive") associated with group membership (e.g., "women"). Such demonstrations stop short of showing that the desire for self-verification can fully transcend the self-other barrier, as in people working to verify ingroup identities (e.g., "Americans are loud") even when such identities are not self-descriptive ("I am quiet and unassuming"). Five studies focus on such ingroup verification strivings. Results indicate that people prefer to interact with individuals who verify their ingroup identities over those who enhance these identities (Experiments 1-5). Strivings for ingroup identity verification were independent of the extent to which the identities were self-descriptive but were stronger among participants who were highly invested in their ingroup identities, as reflected in high certainty of these identities (Experiments 1-4) and high identification with the group (Experiments 1-5). In addition, whereas past demonstrations of self-verification strivings have been limited to efforts to verify the content of identities (Experiments 1 to 3), the findings also show that they strive to verify the valence of their identities (i.e., the extent to which the identities are valued; Experiments 4 and 5). Self-verification strivings, rather than self-enhancement strivings, appeared to motivate participants' strivings for ingroup identity verification. Links to collective self-verification strivings and social identity theory are discussed.
Influenza forecasting with Google Flu Trends.
Dugas, Andrea Freyer; Jalalpour, Mehdi; Gel, Yulia; Levin, Scott; Torcaso, Fred; Igusa, Takeru; Rothman, Richard E
2013-01-01
We developed a practical influenza forecast model based on real-time, geographically focused, and easy to access data, designed to provide individual medical centers with advanced warning of the expected number of influenza cases, thus allowing for sufficient time to implement interventions. Secondly, we evaluated the effects of incorporating a real-time influenza surveillance system, Google Flu Trends, and meteorological and temporal information on forecast accuracy. Forecast models designed to predict one week in advance were developed from weekly counts of confirmed influenza cases over seven seasons (2004-2011) divided into seven training and out-of-sample verification sets. Forecasting procedures using classical Box-Jenkins, generalized linear models (GLM), and generalized linear autoregressive moving average (GARMA) methods were employed to develop the final model and assess the relative contribution of external variables such as, Google Flu Trends, meteorological data, and temporal information. A GARMA(3,0) forecast model with Negative Binomial distribution integrating Google Flu Trends information provided the most accurate influenza case predictions. The model, on the average, predicts weekly influenza cases during 7 out-of-sample outbreaks within 7 cases for 83% of estimates. Google Flu Trend data was the only source of external information to provide statistically significant forecast improvements over the base model in four of the seven out-of-sample verification sets. Overall, the p-value of adding this external information to the model is 0.0005. The other exogenous variables did not yield a statistically significant improvement in any of the verification sets. Integer-valued autoregression of influenza cases provides a strong base forecast model, which is enhanced by the addition of Google Flu Trends confirming the predictive capabilities of search query based syndromic surveillance. This accessible and flexible forecast model can be used by individual medical centers to provide advanced warning of future influenza cases.
Ercoli, Carlo; Geminiani, Alessandro; Feng, Changyong; Lee, Heeje
2012-05-01
The purpose of this retrospective study was to assess if there was a difference in the likelihood of achieving passive fit when an implant-supported full-arch prosthesis framework is fabricated with or without the aid of a verification jig. This investigation was approved by the University of Rochester Research Subject Review Board (protocol #RSRB00038482). Thirty edentulous patients, 49 to 73 years old (mean 61 years old), rehabilitated with a nonsegmented fixed implant-supported complete denture were included in the study. During the restorative process, final impressions were made using the pickup impression technique and elastomeric impression materials. For 16 patients, a verification jig was made (group J), while for the remaining 14 patients, a verification jig was not used (group NJ) and the framework was fabricated directly on the master cast. During the framework try-in appointment, the fit was assessed by clinical (Sheffield test) and radiographic inspection and recorded as passive or nonpassive. When a verification jig was used (group J, n = 16), all frameworks exhibited clinically passive fit, while when a verification jig was not used (group NJ, n = 14), only two frameworks fit. This difference was statistically significant (p < .001). Within the limitations of this retrospective study, the fabrication of a verification jig ensured clinically passive fit of metal frameworks in nonsegmented fixed implant-supported complete denture. © 2011 Wiley Periodicals, Inc.
NASA Technical Reports Server (NTRS)
Chen, I. Y.; Ungar, E. K.; Lee, D. Y.; Beckstrom, P. S.
1993-01-01
To verify the on-orbit operation of the Space Station Freedom (SSF) two-phase external Active Thermal Control System (ATCS), a test and verification program will be performed prior to flight. The first system level test of the ATCS is the Prototype Test Article (PTA) test that will be performed in early 1994. All ATCS loops will be represented by prototypical components and the line sizes and lengths will be representative of the flight system. In this paper, the SSF ATCS and a portion of its verification process are described. The PTA design and the analytical methods that were used to quantify the gravity effects on PTA operation are detailed. Finally, the gravity effects are listed, and the applicability of the 1-g PTA test results to the validation of on-orbit ATCS operation is discussed.
Generating Models of Infinite-State Communication Protocols Using Regular Inference with Abstraction
NASA Astrophysics Data System (ADS)
Aarts, Fides; Jonsson, Bengt; Uijen, Johan
In order to facilitate model-based verification and validation, effort is underway to develop techniques for generating models of communication system components from observations of their external behavior. Most previous such work has employed regular inference techniques which generate modest-size finite-state models. They typically suppress parameters of messages, although these have a significant impact on control flow in many communication protocols. We present a framework, which adapts regular inference to include data parameters in messages and states for generating components with large or infinite message alphabets. A main idea is to adapt the framework of predicate abstraction, successfully used in formal verification. Since we are in a black-box setting, the abstraction must be supplied externally, using information about how the component manages data parameters. We have implemented our techniques by connecting the LearnLib tool for regular inference with the protocol simulator ns-2, and generated a model of the SIP component as implemented in ns-2.
Meyer, Pablo; Hoeng, Julia; Rice, J. Jeremy; Norel, Raquel; Sprengel, Jörg; Stolle, Katrin; Bonk, Thomas; Corthesy, Stephanie; Royyuru, Ajay; Peitsch, Manuel C.; Stolovitzky, Gustavo
2012-01-01
Motivation: Analyses and algorithmic predictions based on high-throughput data are essential for the success of systems biology in academic and industrial settings. Organizations, such as companies and academic consortia, conduct large multi-year scientific studies that entail the collection and analysis of thousands of individual experiments, often over many physical sites and with internal and outsourced components. To extract maximum value, the interested parties need to verify the accuracy and reproducibility of data and methods before the initiation of such large multi-year studies. However, systematic and well-established verification procedures do not exist for automated collection and analysis workflows in systems biology which could lead to inaccurate conclusions. Results: We present here, a review of the current state of systems biology verification and a detailed methodology to address its shortcomings. This methodology named ‘Industrial Methodology for Process Verification in Research’ or IMPROVER, consists on evaluating a research program by dividing a workflow into smaller building blocks that are individually verified. The verification of each building block can be done internally by members of the research program or externally by ‘crowd-sourcing’ to an interested community. www.sbvimprover.com Implementation: This methodology could become the preferred choice to verify systems biology research workflows that are becoming increasingly complex and sophisticated in industrial and academic settings. Contact: gustavo@us.ibm.com PMID:22423044
An Approach to Biometric Verification Based on Human Body Communication in Wearable Devices
Li, Jingzhen; Liu, Yuhang; Nie, Zedong; Qin, Wenjian; Pang, Zengyao; Wang, Lei
2017-01-01
In this paper, an approach to biometric verification based on human body communication (HBC) is presented for wearable devices. For this purpose, the transmission gain S21 of volunteer’s forearm is measured by vector network analyzer (VNA). Specifically, in order to determine the chosen frequency for biometric verification, 1800 groups of data are acquired from 10 volunteers in the frequency range 0.3 MHz to 1500 MHz, and each group includes 1601 sample data. In addition, to achieve the rapid verification, 30 groups of data for each volunteer are acquired at the chosen frequency, and each group contains only 21 sample data. Furthermore, a threshold-adaptive template matching (TATM) algorithm based on weighted Euclidean distance is proposed for rapid verification in this work. The results indicate that the chosen frequency for biometric verification is from 650 MHz to 750 MHz. The false acceptance rate (FAR) and false rejection rate (FRR) based on TATM are approximately 5.79% and 6.74%, respectively. In contrast, the FAR and FRR were 4.17% and 37.5%, 3.37% and 33.33%, and 3.80% and 34.17% using K-nearest neighbor (KNN) classification, support vector machines (SVM), and naive Bayesian method (NBM) classification, respectively. In addition, the running time of TATM is 0.019 s, whereas the running times of KNN, SVM and NBM are 0.310 s, 0.0385 s, and 0.168 s, respectively. Therefore, TATM is suggested to be appropriate for rapid verification use in wearable devices. PMID:28075375
An Approach to Biometric Verification Based on Human Body Communication in Wearable Devices.
Li, Jingzhen; Liu, Yuhang; Nie, Zedong; Qin, Wenjian; Pang, Zengyao; Wang, Lei
2017-01-10
In this paper, an approach to biometric verification based on human body communication (HBC) is presented for wearable devices. For this purpose, the transmission gain S21 of volunteer's forearm is measured by vector network analyzer (VNA). Specifically, in order to determine the chosen frequency for biometric verification, 1800 groups of data are acquired from 10 volunteers in the frequency range 0.3 MHz to 1500 MHz, and each group includes 1601 sample data. In addition, to achieve the rapid verification, 30 groups of data for each volunteer are acquired at the chosen frequency, and each group contains only 21 sample data. Furthermore, a threshold-adaptive template matching (TATM) algorithm based on weighted Euclidean distance is proposed for rapid verification in this work. The results indicate that the chosen frequency for biometric verification is from 650 MHz to 750 MHz. The false acceptance rate (FAR) and false rejection rate (FRR) based on TATM are approximately 5.79% and 6.74%, respectively. In contrast, the FAR and FRR were 4.17% and 37.5%, 3.37% and 33.33%, and 3.80% and 34.17% using K-nearest neighbor (KNN) classification, support vector machines (SVM), and naive Bayesian method (NBM) classification, respectively. In addition, the running time of TATM is 0.019 s, whereas the running times of KNN, SVM and NBM are 0.310 s, 0.0385 s, and 0.168 s, respectively. Therefore, TATM is suggested to be appropriate for rapid verification use in wearable devices.
Gender, Legitimation, and Identity Verification in Groups
ERIC Educational Resources Information Center
Burke, Peter J.; Stets, Jan E.; Cerven, Christine
2007-01-01
Drawing upon identity theory, expectation states theory, and legitimation theory, we examine how the task leader identity in task-oriented groups is more likely to be verified for persons with high status characteristics. We hypothesize that identity verification will be accomplished more readily for male group members and legitimated task leaders…
Static test induced loads verification beyond elastic limit
NASA Technical Reports Server (NTRS)
Verderaime, V.; Harrington, F.
1996-01-01
Increasing demands for reliable and least-cost high-performance aerostructures are pressing design analyses, materials, and manufacturing processes to new and narrowly experienced performance and verification technologies. This study assessed the adequacy of current experimental verification of the traditional binding ultimate safety factor which covers rare events in which no statistical design data exist. Because large high-performance structures are inherently very flexible, boundary rotations and deflections under externally applied loads approaching fracture may distort their transmission and unknowingly accept submarginal structures or prematurely fracturing reliable ones. A technique was developed, using measured strains from back-to-back surface mounted gauges, to analyze, define, and monitor induced moments and plane forces through progressive material changes from total-elastic to total-inelastic zones within the structural element cross section. Deviations from specified test loads are identified by the consecutively changing ratios of moment-to-axial load.
Static test induced loads verification beyond elastic limit
NASA Technical Reports Server (NTRS)
Verderaime, V.; Harrington, F.
1996-01-01
Increasing demands for reliable and least-cost high performance aerostructures are pressing design analyses, materials, and manufacturing processes to new and narrowly experienced performance and verification technologies. This study assessed the adequacy of current experimental verification of the traditional binding ultimate safety factor which covers rare events in which no statistical design data exist. Because large, high-performance structures are inherently very flexible, boundary rotations and deflections under externally applied loads approaching fracture may distort their transmission and unknowingly accept submarginal structures or prematurely fracturing reliable ones. A technique was developed, using measured strains from back-to-back surface mounted gauges, to analyze, define, and monitor induced moments and plane forces through progressive material changes from total-elastic to total inelastic zones within the structural element cross section. Deviations from specified test loads are identified by the consecutively changing ratios of moment-to-axial load.
Formal verification of a fault tolerant clock synchronization algorithm
NASA Technical Reports Server (NTRS)
Rushby, John; Vonhenke, Frieder
1989-01-01
A formal specification and mechanically assisted verification of the interactive convergence clock synchronization algorithm of Lamport and Melliar-Smith is described. Several technical flaws in the analysis given by Lamport and Melliar-Smith were discovered, even though their presentation is unusally precise and detailed. It seems that these flaws were not detected by informal peer scrutiny. The flaws are discussed and a revised presentation of the analysis is given that not only corrects the flaws but is also more precise and easier to follow. Some of the corrections to the flaws require slight modifications to the original assumptions underlying the algorithm and to the constraints on its parameters, and thus change the external specifications of the algorithm. The formal analysis of the interactive convergence clock synchronization algorithm was performed using the Enhanced Hierarchical Development Methodology (EHDM) formal specification and verification environment. This application of EHDM provides a demonstration of some of the capabilities of the system.
Additional Evidence for the Accuracy of Biographical Data: Long-Term Retest and Observer Ratings.
ERIC Educational Resources Information Center
Shaffer, Garnett Stokes; And Others
1986-01-01
Investigated accuracy of responses to biodata questionnaire using a test-retest design and informed external observers for verification. Responses from 237 subjects and 200 observers provided evidence that many responses to biodata questionnaire were accurate. Assessed sources of inaccuracy, including social desirability effects, and noted…
Abstract for 1999 Rational Software User Conference
NASA Technical Reports Server (NTRS)
Dunphy, Julia; Rouquette, Nicolas; Feather, Martin; Tung, Yu-Wen
1999-01-01
We develop spacecraft fault-protection software at NASA/JPL. Challenges exemplified by our task: 1) high-quality systems - need for extensive validation & verification; 2) multi-disciplinary context - involves experts from diverse areas; 3) embedded systems - must adapt to external practices, notations, etc.; and 4) development pressures - NASA's mandate of "better, faster, cheaper".
Verification measurements of the IRMM-1027 and the IAEA large-sized dried (LSD) spikes.
Jakopič, R; Aregbe, Y; Richter, S; Zuleger, E; Mialle, S; Balsley, S D; Repinc, U; Hiess, J
2017-01-01
In the frame of the accountancy measurements of the fissile materials, reliable determinations of the plutonium and uranium content in spent nuclear fuel are required to comply with international safeguards agreements. Large-sized dried (LSD) spikes of enriched 235 U and 239 Pu for isotope dilution mass spectrometry (IDMS) analysis are routinely applied in reprocessing plants for this purpose. A correct characterisation of these elements is a pre-requirement for achieving high accuracy in IDMS analyses. This paper will present the results of external verification measurements of such LSD spikes performed by the European Commission and the International Atomic Energy Agency.
The U.S. Environmental Protection Agency (EPA) has created the Environmental Technology Verification (ETV) program to facilitate the deployment of innovative or improved environmental technologies through performance verification and dissemination of information. The goal of the ...
Space Shuttle External Tank Project status
NASA Technical Reports Server (NTRS)
Davis, R. M.
1980-01-01
The External Tank Project is reviewed with emphasis on the DDT&E and production phases and the lightweight tank development. It is noted that the DDT&E phase is progressing well with the structural and ground vibration test article programs complete, the propulsion test article program progressing well, and the component qualification and verification testing 92% complete. New tools and facilities are being brought on line to support the increased build rate for the production phase. The lightweight tank, which will provide additional payload in orbit, is progressing to schedule with first delivery in early 1982.
Does the Community of Inquiry Framework Predict Outcomes in Online MBA Courses?
ERIC Educational Resources Information Center
Arbaugh, J. B.
2008-01-01
While Garrison and colleagues' (2000) Community of Inquiry (CoI) framework has generated substantial interest among online learning researchers, it has yet to be subjected to extensive quantitative verification or tested for external validity. Using a sample of students from 55 online MBA courses, the findings of this study suggest strong…
Requirements Development for the NASA Advanced Engineering Environment (AEE)
NASA Technical Reports Server (NTRS)
Rogers, Eric; Hale, Joseph P.; Zook, Keith; Gowda, Sanjay; Salas, Andrea O.
2003-01-01
The requirements development process for the Advanced Engineering Environment (AEE) is presented. This environment has been developed to allow NASA to perform independent analysis and design of space transportation architectures and technologies. Given the highly collaborative and distributed nature of AEE, a variety of organizations are involved in the development, operations and management of the system. Furthermore, there are additional organizations involved representing external customers and stakeholders. Thorough coordination and effective communication is essential to translate desired expectations of the system into requirements. Functional, verifiable requirements for this (and indeed any) system are necessary to fulfill several roles. Requirements serve as a contractual tool, configuration management tool, and as an engineering tool, sometimes simultaneously. The role of requirements as an engineering tool is particularly important because a stable set of requirements for a system provides a common framework of system scope and characterization among team members. Furthermore, the requirements provide the basis for checking completion of system elements and form the basis for system verification. Requirements are at the core of systems engineering. The AEE Project has undertaken a thorough process to translate the desires and expectations of external customers and stakeholders into functional system-level requirements that are captured with sufficient rigor to allow development planning, resource allocation and system-level design, development, implementation and verification. These requirements are maintained in an integrated, relational database that provides traceability to governing Program requirements and also to verification methods and subsystem-level requirements.
Advanced thermionic converter developments with microwave external pumping
NASA Technical Reports Server (NTRS)
Chiu, H. S.; Shaw, D. T.; Manikopulos, C. N.; Lee, C. H.
1977-01-01
This work reports ion generation in a cesium thermionic converter as part of advanced-model thermionic converter development research. A microwave with frequency in the range between 1-2 GHz is used to externally pump a thermionic converter as part of our effort in the verification of Lam's theory. It is found that the motive peak as predicted in the theory disappears whenever microwave power is used to excite the cesium plasma of the converter. The electron temperature is effectively heated by the microwave and the experimental data agrees with theory in the low-power output region.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jannik, Tim; Stagich, Brooke
The U.S. Environmental Protection Agency (EPA) requested an external, independent verification study of their updated “Preliminary Remediation Goals for Radionuclides” (PRG) electronic calculator. The calculator provides PRGs for radionuclides that are used as a screening tool at Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) and Resource Conservation and Recovery Act (RCRA) sites. These risk-based PRGs establish concentration limits under specific exposure scenarios. The purpose of this verification study is to determine that the calculator has no inherit numerical problems with obtaining solutions as well as to ensure that the equations are programmed correctly. There are 167 equations used inmore » the calculator. To verify the calculator, all equations for each of seven receptor types (resident, construction worker, outdoor and indoor worker, recreator, farmer, and composite worker) were hand calculated using the default parameters. The same four radionuclides (Am-241, Co-60, H-3, and Pu-238) were used for each calculation for consistency throughout.« less
A Verification Method of Inter-Task Cooperation in Embedded Real-time Systems and its Evaluation
NASA Astrophysics Data System (ADS)
Yoshida, Toshio
In software development process of embedded real-time systems, the design of the task cooperation process is very important. The cooperating process of such tasks is specified by task cooperation patterns. Adoption of unsuitable task cooperation patterns has fatal influence on system performance, quality, and extendibility. In order to prevent repetitive work caused by the shortage of task cooperation performance, it is necessary to verify task cooperation patterns in an early software development stage. However, it is very difficult to verify task cooperation patterns in an early software developing stage where task program codes are not completed yet. Therefore, we propose a verification method using task skeleton program codes and a real-time kernel that has a function of recording all events during software execution such as system calls issued by task program codes, external interrupts, and timer interrupt. In order to evaluate the proposed verification method, we applied it to the software development process of a mechatronics control system.
Interpreter composition issues in the formal verification of a processor-memory module
NASA Technical Reports Server (NTRS)
Fura, David A.; Cohen, Gerald C.
1994-01-01
This report describes interpreter composition techniques suitable for the formal specification and verification of a processor-memory module using the HOL theorem proving system. The processor-memory module is a multichip subsystem within a fault-tolerant embedded system under development within the Boeing Defense and Space Group. Modeling and verification methods were developed that permit provably secure composition at the transaction-level of specification, significantly reducing the complexity of the hierarchical verification of the system.
Prakash, Varuna; Koczmara, Christine; Savage, Pamela; Trip, Katherine; Stewart, Janice; McCurdie, Tara; Cafazzo, Joseph A; Trbovich, Patricia
2014-11-01
Nurses are frequently interrupted during medication verification and administration; however, few interventions exist to mitigate resulting errors, and the impact of these interventions on medication safety is poorly understood. The study objectives were to (A) assess the effects of interruptions on medication verification and administration errors, and (B) design and test the effectiveness of targeted interventions at reducing these errors. The study focused on medication verification and administration in an ambulatory chemotherapy setting. A simulation laboratory experiment was conducted to determine interruption-related error rates during specific medication verification and administration tasks. Interventions to reduce these errors were developed through a participatory design process, and their error reduction effectiveness was assessed through a postintervention experiment. Significantly more nurses committed medication errors when interrupted than when uninterrupted. With use of interventions when interrupted, significantly fewer nurses made errors in verifying medication volumes contained in syringes (16/18; 89% preintervention error rate vs 11/19; 58% postintervention error rate; p=0.038; Fisher's exact test) and programmed in ambulatory pumps (17/18; 94% preintervention vs 11/19; 58% postintervention; p=0.012). The rate of error commission significantly decreased with use of interventions when interrupted during intravenous push (16/18; 89% preintervention vs 6/19; 32% postintervention; p=0.017) and pump programming (7/18; 39% preintervention vs 1/19; 5% postintervention; p=0.017). No statistically significant differences were observed for other medication verification tasks. Interruptions can lead to medication verification and administration errors. Interventions were highly effective at reducing unanticipated errors of commission in medication administration tasks, but showed mixed effectiveness at reducing predictable errors of detection in medication verification tasks. These findings can be generalised and adapted to mitigate interruption-related errors in other settings where medication verification and administration are required. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
The Environmental Technology Verification report discusses the technology and performance of the AeroStar "C-Series" Polyester Panel Filter air filter for dust and bioaerosol filtration manufactured by Filtration Group. The pressure drop across the filter was 126 Pa clean and 267...
Towards the formal verification of the requirements and design of a processor interface unit
NASA Technical Reports Server (NTRS)
Fura, David A.; Windley, Phillip J.; Cohen, Gerald C.
1993-01-01
The formal verification of the design and partial requirements for a Processor Interface Unit (PIU) using the Higher Order Logic (HOL) theorem-proving system is described. The processor interface unit is a single-chip subsystem within a fault-tolerant embedded system under development within the Boeing Defense and Space Group. It provides the opportunity to investigate the specification and verification of a real-world subsystem within a commercially-developed fault-tolerant computer. An overview of the PIU verification effort is given. The actual HOL listing from the verification effort are documented in a companion NASA contractor report entitled 'Towards the Formal Verification of the Requirements and Design of a Processor Interface Unit - HOL Listings' including the general-purpose HOL theories and definitions that support the PIU verification as well as tactics used in the proofs.
External Contamination Control of Attached Payloads on the International Space Station
NASA Technical Reports Server (NTRS)
Soares, Carlos E.; Mikatarian, Ronald R.; Olsen, Randy L.; Huang, Alvin Y.; Steagall, Courtney A.; Schmidl, William D.; Wright, Bruce D.; Koontz, Steven
2012-01-01
The International Space Station (ISS) is an on-orbit platform for science utilization in low Earth orbit with multiple sites for external payloads with exposure to the natural and induced environments. Contamination is one of the induced environments that can impact performance, mission success and science utilization on the vehicle. This paper describes the external contamination control requirements and integration process for externally mounted payloads on the ISS. The external contamination control requirements are summarized and a description of the integration and verification process is detailed to guide payload developers in the certification process of attached payloads on the vehicle. A description of the required data certification deliverables covers the characterization of contamination sources. Such characterization includes identification, usage and operational data for each class of contamination source. Classes of external contamination sources covered are vacuum exposed materials, sources of leakage, vacuum venting and thrusters. ISS system level analyses are conducted by the ISS Space Environments Team to certify compliance with external contamination control requirements. This paper also addresses the ISS induced contamination environment at attached payload sites, both at the requirements level as well as measurements made on ISS.
[The study of noninvasive ventilator impeller based on ANSYS].
Hu, Zhaoyan; Lu, Pan; Xie, Haiming; Zhou, Yaxu
2011-06-01
An impeller plays a significant role in the non-invasive ventilator. This paper shows a model of impeller for noninvasive ventilator established with the software Solidworks. The model was studied for feasibility based on ANSYS. Then stress and strain of the impeller were discussed under the external loads. The results of the analysis provided verification for the reliable design of impellers.
Thermal testing by internal IR heating of the FEP module
NASA Technical Reports Server (NTRS)
Nathanson, D. M.; Efromson, R. A.; Lee, E. I.
1986-01-01
A spacecraft module, to be integrated with the FLTSATCOM spacecraft, was tested in a simulated orbit environment separate from the host spacecraft. Thermal vacuum testing of the module was accomplished using internal IR heating rather than conventional external heat sources. For this configuration, the technique produced boundary conditions expected for flight to enable verification of system performance and thermal design details.
The Environmental Technology Verification report discusses the technology and performance of the AeroStar FP-98 Minipleat V-Bank Filter air filter for dust and bioaerosol filtration manufactured by Filtration Group. The pressure drop across the filter was 137 Pa clean and 348 Pa ...
STS-96 crew takes part in payload Interface Verification Test
NASA Technical Reports Server (NTRS)
1999-01-01
At the SPACEHAB Facility, STS-96 Mission Specialist Ellen Ochoa and Commander Kent Rominger pause during a payload Interface Verification Test (IVT) for their upcoming mission to the International Space Station. Other crew members at KSC for the IVT are Pilot Rick Husband and Mission Specialists Tamara Jernigan, Dan Barry, Julie Payette and Valery Tokarev of Russia. Mission STS-96 carries the SPACEHAB Logistics Double Module, which will have equipment to further outfit the International Space Station service module and equipment that can be off-loaded from the early U.S. assembly flights. It carries internal logistics and resupply cargo for station outfitting, plus an external Russian cargo crane to be mounted to the exterior of the Russian station segment and used to perform space walking maintenance activities. The double module stowage provides capacity of up to 10,000 lbs. with the ability to accommodate powered payloads, four external rooftop stowage locations, four double-rack locations (two powered), up to 61 bulkhead-mounted middeck locker locations, and floor storage for large unique items and Soft Stowage. STS-96 is targeted to launch May 20 about 9:32 a.m. EDT.
STS-96 crew takes part in payload Interface Verification Test
NASA Technical Reports Server (NTRS)
1999-01-01
In the SPACEHAB Facility, STS-96 Mission Specialist Julie Payette closes a container, part of the equipment to be carried on the SPACEHAB and mission STS-96. She and other crew members Commander Kent Rominger, Pilot Rick Husband, and Mission Speciaists Ellen Ochoa, Tamara Jernigan, Dan Barry and Valery Tokarev of Russia are at KSC for a payload Interface Verification Test for the upcoming mission to the International Space Station . Mission STS-96 carries the SPACEHAB Logistics Double Module, which has equipment to further outfit the International Space Station service module and equipment that can be off-loaded from the early U.S. assembly flights. The SPACEHAB carries internal logistics and resupply cargo for station outfitting, plus an external Russian cargo crane to be mounted to the exterior of the Russian station segment and used to perform space walking maintenance activities. The double module stowage provides capacity of up to 10,000 lbs. with the ability to accommodate powered payloads, four external rooftop stowage locations, four double-rack locations (two powered), up to 61 bulkhead-mounted middeck locker locations, and floor storage for large unique items and Soft Stowage. STS-96 is targeted to launch May 20 about 9:32 a.m.
STS-96 crew takes part in payload Interface Verification Test
NASA Technical Reports Server (NTRS)
1999-01-01
Posing on the platform next to the SPACEHAB Logistics Double Module in the SPACEHAB Facility are the STS-96 crew (from left) Mission Specialists Dan Barry, Tamara Jernigan, Valery Tokarev of Russia, and Julie Payette; Pilot Rick Husband; Mission Specialist Ellen Ochoa; and Commander Kent Rominger. The crew is at KSC for a payload Interface Verification Test for their upcoming mission to the International Space Station. Mission STS-96 carries the SPACEHAB Logistics Double Module, which will have equipment to further outfit the International Space Station service module and equipment that can be off-loaded from the early U.S. assembly flights. It carries internal logistics and resupply cargo for station outfitting, plus an external Russian cargo crane to be mounted to the exterior of the Russian station segment and used to perform space walking maintenance activities. The double module stowage provides capacity of up to 10,000 lbs. with the ability to accommodate powered payloads, four external rooftop stowage locations, four double-rack locations (two powered), up to 61 bulkhead-mounted middeck locker locations, and floor storage for large unique items and Soft Stowage. STS-96 is targeted to launch May 20 about 9:32 a.m.
STS-96 crew takes part in payload Interface Verification Test
NASA Technical Reports Server (NTRS)
1999-01-01
At the SPACEHAB Facility, STS-96 Mission Specialist Ellen Ochoa and Commander Kent Rominger smile for the camera during a payload Interface Verification Test (IVT) for their upcoming mission to the International Space Station. Other crew members at KSC for the IVT are Pilot Rick Husband and Mission Specialists Tamara Jernigan, Dan Barry, Julie Payette and Valery Tokarev of Russia. Mission STS-96 carries the SPACEHAB Logistics Double Module, which will have equipment to further outfit the International Space Station service module and equipment that can be off-loaded from the early U.S. assembly flights. It carries internal logistics and resupply cargo for station outfitting, plus an external Russian cargo crane to be mounted to the exterior of the Russian station segment and used to perform space walking maintenance activities. The double module stowage provides capacity of up to 10,000 lbs. with the ability to accommodate powered payloads, four external rooftop stowage locations, four double-rack locations (two powered), up to 61 bulkhead-mounted middeck locker locations, and floor storage for large unique items and Soft Stowage. STS-96 is targeted to launch May 20 about 9:32 a.m. EDT.
STS-96 crew takes part in payload Interface Verification Test
NASA Technical Reports Server (NTRS)
1999-01-01
During a payload Interface Verification Test (IVT) for the upcoming mission to the International Space Station , Chris Jaskolka of Boeing points out a piece of equipment in the SPACEHAB module to STS-96 Commander Kent Rominger, Mission Specialist Ellen Ochoa and Pilot Rick Husband. Other crew members visiting KSC for the IVT are Mission Specialists Tamara Jernigan, Dan Barry, Julie Payette and Valery Tokarev of Russia. Mission STS-96 carries the SPACEHAB Logistics Double Module, which will have equipment to further outfit the International Space Station service module and equipment that can be off-loaded from the early U.S. assembly flights. It carries internal logistics and resupply cargo for station outfitting, plus an external Russian cargo crane to be mounted to the exterior of the Russian station segment and used to perform space walking maintenance activities. The double module stowage provides capacity of up to 10,000 lbs. with the ability to accommodate powered payloads, four external rooftop stowage locations, four double-rack locations (two powered), up to 61 bulkhead-mounted middeck locker locations, and floor storage for large unique items and Soft Stowage. STS-96 is targeted to launch May 20 about 9:32 a.m. EDT.
STS-96 crew takes part in payload Interface Verification Test
NASA Technical Reports Server (NTRS)
1999-01-01
In the SPACEHAB Facility, STS-96 Mission Specialists Dan Barry and Tamara Jernigan discuss procedures during a payload Interface Verification Test (IVT) for their upcoming mission to the International Space Station. Other STS-96 crew members at KSC for the IVT are Commander Kent Rominger, Pilot Rick Husband and Mission Specialists Ellen Ochoa, Julie Payette and Valery Tokarev of Russia. Mission STS-96 carries the SPACEHAB Logistics Double Module, which will have equipment to further outfit the International Space Station service module and equipment that can be off-loaded from the early U.S. assembly flights. It carries internal logistics and resupply cargo for station outfitting, plus an external Russian cargo crane to be mounted to the exterior of the Russian station segment and used to perform space walking maintenance activities. The double module stowage provides capacity of up to 10,000 lbs. with the ability to accommodate powered payloads, four external rooftop stowage locations, four double-rack locations (two powered), up to 61 bulkhead-mounted middeck locker locations, and floor storage for large unique items and Soft Stowage. STS-96 is targeted to launch May 20 about 9:32 a.m.
STS-96 crew takes part in payload Interface Verification Test
NASA Technical Reports Server (NTRS)
1999-01-01
In the SPACEHAB Facility, James Behling, with Boeing, talks about equipment for mission STS-96 during a payload Interface Verification Test (IVT). Watching are (from left) Mission Specialists Ellen Ochoa, Julie Payette and Dan Berry, and Pilot Rick Husband. Other STS-96 crew members at KSC for the IVT are Commander Kent Rominger and Mission Specialists Tamara Jernigan and Valery Tokarev of Russia. Mission STS-96 carries the SPACEHAB Logistics Double Module, which will have equipment to further outfit the International Space Station service module and equipment that can be off-loaded from the early U.S. assembly flights. It carries internal logistics and resupply cargo for station outfitting, plus an external Russian cargo crane to be mounted to the exterior of the Russian station segment and used to perform space walking maintenance activities. The double module stowage provides capacity of up to 10,000 lbs. with the ability to accommodate powered payloads, four external rooftop stowage locations, four double-rack locations (two powered), up to 61 bulkhead-mounted middeck locker locations, and floor storage for large unique items and Soft Stowage. STS-96 is targeted to launch May 20 about 9:32 a.m.
STS-96 crew takes part in payload Interface Verification Test
NASA Technical Reports Server (NTRS)
1999-01-01
During a payload Interface Verification Test (IVT) for their upcoming mission to the International Space Station, STS-96 Mission Specialists Julie Payette, Dan Barry, and Valery Tokarev of Russia, look at a Sequential Shunt Unit in the SPACEHAB Facility. Other crew members at KSC for the IVT are Commander Kent Rominger, Pilot Rick Husband, and Mission Specialists Ellen Ochoa and Tamara Jernigan. Mission STS-96 carries the SPACEHAB Logistics Double Module, which will have equipment to further outfit the International Space Station service module and equipment that can be off-loaded from the early U.S. assembly flights. It carries internal logistics and resupply cargo for station outfitting, plus an external Russian cargo crane to be mounted to the exterior of the Russian station segment and used to perform space walking maintenance activities. The double module stowage provides capacity of up to 10,000 lbs. with the ability to accommodate powered payloads, four external rooftop stowage locations, four double-rack locations (two powered), up to 61 bulkhead-mounted middeck locker locations, and floor storage for large unique items and Soft Stowage. STS-96 is targeted to launch May 20 about 9:32 a.m. EDT.
STS-96 crew takes part in payload Interface Verification Test
NASA Technical Reports Server (NTRS)
1999-01-01
In the SPACEHAB Facility for a payload Interface Verification Test (IVT) for their upcoming mission to the International Space Station are (left to right) Mission Specialists Valery Tokarev, Julie Payette (holding a lithium hydroxide canister) and Dan Barry. Other crew members at KSC for the IVT are Commander Kent Rominger, Pilot Rick Husband and Mission Specialists Ellen Ochoa and Tamara Jernigan. Mission STS-96 carries the SPACEHAB Logistics Double Module, which has equipment to further outfit the International Space Station service module and equipment that can be off-loaded from the early U.S. assembly flights. The SPACEHAB carries internal logistics and resupply cargo for station outfitting, plus an external Russian cargo crane to be mounted to the exterior of the Russian station segment and used to perform space walking maintenance activities. The double module stowage provides capacity of up to 10,000 lbs. with the ability to accommodate powered payloads, four external rooftop stowage locations, four double-rack locations (two powered), up to 61 bulkhead-mounted middeck locker locations, and floor storage for large unique items and Soft Stowage. STS-96 is targeted to launch May 20 about 9:32 a.m.
STS-96 crew takes part in payload Interface Verification Test
NASA Technical Reports Server (NTRS)
1999-01-01
In the SPACEHAB Facility, the STS-96 crew looks over equipment during a payload Interface Verification Test for the upcoming mission to the International Space Station. From left are Commander Kent Rominger, Mission Specialists Tamara Jernigan and Valery Tokarev of Russia, Pilot Rick Husband, and Mission Specialists Ellen Ochoa and Julie Payette (backs to the camera). They are listening to Chris Jaskolka of Boeing talk about the equipment. Mission STS-96 carries the SPACEHAB Logistics Double Module, which will have equipment to further outfit the International Space Station service module and equipment that can be off-loaded from the early U.S. assembly flights. It carries internal logistics and resupply cargo for station outfitting, plus an external Russian cargo crane to be mounted to the exterior of the Russian station segment and used to perform space walking maintenance activities. The double module stowage provides capacity of up to 10,000 lbs. with the ability to accommodate powered payloads, four external rooftop stowage locations, four double-rack locations (two powered), up to 61 bulkhead-mounted middeck locker locations, and floor storage for large unique items and Soft Stowage. STS-96 is targeted to launch May 20 about 9:32 a.m. EDT.
Optimum-AIV: A planning and scheduling system for spacecraft AIV
NASA Technical Reports Server (NTRS)
Arentoft, M. M.; Fuchs, Jens J.; Parrod, Y.; Gasquet, Andre; Stader, J.; Stokes, I.; Vadon, H.
1991-01-01
A project undertaken for the European Space Agency (ESA) is presented. The project is developing a knowledge based software system for planning and scheduling of activities for spacecraft assembly, integration, and verification (AIV). The system extends into the monitoring of plan execution and the plan repair phase. The objectives are to develop an operational kernel of a planning, scheduling, and plan repair tool, called OPTIMUM-AIV, and to provide facilities which will allow individual projects to customize the kernel to suit its specific needs. The kernel shall consist of a set of software functionalities for assistance in initial specification of the AIV plan, in verification and generation of valid plans and schedules for the AIV activities, and in interactive monitoring and execution problem recovery for the detailed AIV plans. Embedded in OPTIMUM-AIV are external interfaces which allow integration with alternative scheduling systems and project databases. The current status of the OPTIMUM-AIV project, as of Jan. 1991, is that a further analysis of the AIV domain has taken place through interviews with satellite AIV experts, a software requirement document (SRD) for the full operational tool was approved, and an architectural design document (ADD) for the kernel excluding external interfaces is ready for review.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dewberry, R.; Ayers, J.; Tietze, F.
The Analytical Development (AD) Section field nuclear measurement group performed six 'best available technique' verification measurements to satisfy a DOE requirement instituted for the March 2009 semi-annual inventory. The requirement of (1) yielded the need for SRNL Research Operations Department Material Control & Accountability (MC&A) group to measure the Pu content of five items and the highly enrich uranium (HEU) content of two. No 14Q-qualified measurement equipment was available to satisfy the requirement. The AD field nuclear group has routinely performed the required Confirmatory Measurements for the semi-annual inventories for fifteen years using sodium iodide and high purity germanium (HpGe)more » {gamma}-ray pulse height analysis nondestructive assay (NDA) instruments. With appropriate {gamma}-ray acquisition modeling, the HpGe spectrometers can be used to perform verification-type quantitative assay for Pu-isotopics and HEU content. The AD nuclear NDA group is widely experienced with this type of measurement and reports content for these species in requested process control, MC&A booking, and holdup measurements assays Site-wide. However none of the AD HpGe {gamma}-ray spectrometers have been 14Q-qualified, and the requirement of reference 1 specifically excluded a {gamma}-ray PHA measurement from those it would accept for the required verification measurements. The requirement of reference 1 was a new requirement for which the Savannah River National Laboratory (SRNL) Research Operations Department (ROD) MC&A group was unprepared. The criteria for exemption from verification were: (1) isotope content below 50 grams; (2) intrinsically tamper indicating or TID sealed items which contain a Category IV quantity of material; (3) assembled components; and (4) laboratory samples. Therefore all (SRNL) Material Balance Area (MBA) items with greater than 50 grams total Pu or greater than 50 grams HEU were subject to a verification measurement. The pass/fail criteria of reference 7 stated 'The facility will report measured values, book values, and statistical control limits for the selected items to DOE SR...', and 'The site/facility operator must develop, document, and maintain measurement methods for all nuclear material on inventory'. These new requirements exceeded SRNL's experience with prior semi-annual inventory expectations, but allowed the AD nuclear field measurement group to demonstrate its excellent adaptability and superior flexibility to respond to unpredicted expectations from the DOE customer. The requirements yielded five SRNL items subject to Pu verification and two SRNL items subject to HEU verification. These items are listed and described in Table 1.« less
External tank aerothermal design criteria verification, volume 1
NASA Technical Reports Server (NTRS)
Crain, William K.; Frost, Cynthia; Warmbrod, John
1990-01-01
The objective of this study was to produce an independent set of ascent environments which would serve as a check on the Rockwell IVBC-3 environments and provide an independent reevaluation of the thermal design criteria for the External Tank (ET). Design heating rates and loads were calculated at 367 acreage body point locations. Ascent flight regimes covered were lift-off, first stage ascent, Solid Rocket Booster (SRB) staging and second stage ascent through ET separation. The purpose here is to document these results, briefly describe the methodology used and present the environments along with a comparison with the Rockwell IVBC-3 counterpart. The methodology and environment summaries are given.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bojechko, Casey; Phillps, Mark; Kalet, Alan
Purpose: Complex treatments in radiation therapy require robust verification in order to prevent errors that can adversely affect the patient. For this purpose, the authors estimate the effectiveness of detecting errors with a “defense in depth” system composed of electronic portal imaging device (EPID) based dosimetry and a software-based system composed of rules-based and Bayesian network verifications. Methods: The authors analyzed incidents with a high potential severity score, scored as a 3 or 4 on a 4 point scale, recorded in an in-house voluntary incident reporting system, collected from February 2012 to August 2014. The incidents were categorized into differentmore » failure modes. The detectability, defined as the number of incidents that are detectable divided total number of incidents, was calculated for each failure mode. Results: In total, 343 incidents were used in this study. Of the incidents 67% were related to photon external beam therapy (EBRT). The majority of the EBRT incidents were related to patient positioning and only a small number of these could be detected by EPID dosimetry when performed prior to treatment (6%). A large fraction could be detected by in vivo dosimetry performed during the first fraction (74%). Rules-based and Bayesian network verifications were found to be complimentary to EPID dosimetry, able to detect errors related to patient prescriptions and documentation, and errors unrelated to photon EBRT. Combining all of the verification steps together, 91% of all EBRT incidents could be detected. Conclusions: This study shows that the defense in depth system is potentially able to detect a large majority of incidents. The most effective EPID-based dosimetry verification is in vivo measurements during the first fraction and is complemented by rules-based and Bayesian network plan checking.« less
[Validation and verfication of microbiology methods].
Camaró-Sala, María Luisa; Martínez-García, Rosana; Olmos-Martínez, Piedad; Catalá-Cuenca, Vicente; Ocete-Mochón, María Dolores; Gimeno-Cardona, Concepción
2015-01-01
Clinical microbiologists should ensure, to the maximum level allowed by the scientific and technical development, the reliability of the results. This implies that, in addition to meeting the technical criteria to ensure their validity, they must be performed with a number of conditions that allows comparable results to be obtained, regardless of the laboratory that performs the test. In this sense, the use of recognized and accepted reference methodsis the most effective tool for these guarantees. The activities related to verification and validation of analytical methods has become very important, as there is continuous development, as well as updating techniques and increasingly complex analytical equipment, and an interest of professionals to ensure quality processes and results. The definitions of validation and verification are described, along with the different types of validation/verification, and the types of methods, and the level of validation necessary depending on the degree of standardization. The situations in which validation/verification is mandatory and/or recommended is discussed, including those particularly related to validation in Microbiology. It stresses the importance of promoting the use of reference strains as controls in Microbiology and the use of standard controls, as well as the importance of participation in External Quality Assessment programs to demonstrate technical competence. The emphasis is on how to calculate some of the parameters required for validation/verification, such as the accuracy and precision. The development of these concepts can be found in the microbiological process SEIMC number 48: «Validation and verification of microbiological methods» www.seimc.org/protocols/microbiology. Copyright © 2013 Elsevier España, S.L.U. y Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.
Van Hoof, Joris J
2017-04-01
Currently, two different age verification systems (AVS) are implemented to enhance compliance with legal age limits for the sale of alcohol in the Netherlands. In this study, we tested the operational procedures and effectiveness of ID readers and remote age verification technology in supermarkets during the sale of alcohol. Following a trained alcohol purchase protocol, eight mystery shoppers (both underage and in the branch's reference age) conducted 132 alcohol purchase attempts in stores that were equipped with ID readers or remote age verification or were part of a control group. In stores equipped with an ID reader, 34% of the purchases were conducted without any mistakes (full compliance). In stores with remote age verification, full compliance was achieved in 87% of the cases. The control group reached 57% compliance, which is in line with the national average. Stores with ID readers perform worse than stores with remote age verification, and also worse than stores without any AVS. For both systems, in addition to effectiveness, public support and user friendliness need to be investigated. This study shows that remote age verification technology is a promising intervention that increases vendor compliance during the sales of age restricted products. © The Author 2016. Published by Oxford University Press on behalf of the European Public Health Association. All rights reserved.
Interface Management for a NASA Flight Project Using Model-Based Systems Engineering (MBSE)
NASA Technical Reports Server (NTRS)
Vipavetz, Kevin; Shull, Thomas A.; Infeld, Samatha; Price, Jim
2016-01-01
The goal of interface management is to identify, define, control, and verify interfaces; ensure compatibility; provide an efficient system development; be on time and within budget; while meeting stakeholder requirements. This paper will present a successful seven-step approach to interface management used in several NASA flight projects. The seven-step approach using Model Based Systems Engineering will be illustrated by interface examples from the Materials International Space Station Experiment-X (MISSE-X) project. The MISSE-X was being developed as an International Space Station (ISS) external platform for space environmental studies, designed to advance the technology readiness of materials and devices critical for future space exploration. Emphasis will be given to best practices covering key areas such as interface definition, writing good interface requirements, utilizing interface working groups, developing and controlling interface documents, handling interface agreements, the use of shadow documents, the importance of interface requirement ownership, interface verification, and product transition.
Design and Verification of External Occulters for Direct Imaging of Extrasolar Planets
NASA Technical Reports Server (NTRS)
Cady, Eric
2011-01-01
An occulter is an optical element which is placed in front of the telescope to block most of the light from a star before it reaches the optics inside, without blocking the planet.In our case, we use two spacecraft ying in formation: First has its edge shaped to cancel the starlight Second is the telescope which images the star and planet
Stern, Robin L; Heaton, Robert; Fraser, Martin W; Goddu, S Murty; Kirby, Thomas H; Lam, Kwok Leung; Molineu, Andrea; Zhu, Timothy C
2011-01-01
The requirement of an independent verification of the monitor units (MU) or time calculated to deliver the prescribed dose to a patient has been a mainstay of radiation oncology quality assurance. The need for and value of such a verification was obvious when calculations were performed by hand using look-up tables, and the verification was achieved by a second person independently repeating the calculation. However, in a modern clinic using CT/MR/PET simulation, computerized 3D treatment planning, heterogeneity corrections, and complex calculation algorithms such as convolution/superposition and Monte Carlo, the purpose of and methodology for the MU verification have come into question. In addition, since the verification is often performed using a simpler geometrical model and calculation algorithm than the primary calculation, exact or almost exact agreement between the two can no longer be expected. Guidelines are needed to help the physicist set clinically reasonable action levels for agreement. This report addresses the following charges of the task group: (1) To re-evaluate the purpose and methods of the "independent second check" for monitor unit calculations for non-IMRT radiation treatment in light of the complexities of modern-day treatment planning. (2) To present recommendations on how to perform verification of monitor unit calculations in a modern clinic. (3) To provide recommendations on establishing action levels for agreement between primary calculations and verification, and to provide guidance in addressing discrepancies outside the action levels. These recommendations are to be used as guidelines only and shall not be interpreted as requirements.
Hiraishi, Kunihiko
2014-01-01
One of the significant topics in systems biology is to develop control theory of gene regulatory networks (GRNs). In typical control of GRNs, expression of some genes is inhibited (activated) by manipulating external stimuli and expression of other genes. It is expected to apply control theory of GRNs to gene therapy technologies in the future. In this paper, a control method using a Boolean network (BN) is studied. A BN is widely used as a model of GRNs, and gene expression is expressed by a binary value (ON or OFF). In particular, a context-sensitive probabilistic Boolean network (CS-PBN), which is one of the extended models of BNs, is used. For CS-PBNs, the verification problem and the optimal control problem are considered. For the verification problem, a solution method using the probabilistic model checker PRISM is proposed. For the optimal control problem, a solution method using polynomial optimization is proposed. Finally, a numerical example on the WNT5A network, which is related to melanoma, is presented. The proposed methods provide us useful tools in control theory of GRNs. PMID:24587766
Validation of the Economic and Health Outcomes Model of Type 2 Diabetes Mellitus (ECHO-T2DM).
Willis, Michael; Johansen, Pierre; Nilsson, Andreas; Asseburg, Christian
2017-03-01
The Economic and Health Outcomes Model of Type 2 Diabetes Mellitus (ECHO-T2DM) was developed to address study questions pertaining to the cost-effectiveness of treatment alternatives in the care of patients with type 2 diabetes mellitus (T2DM). Naturally, the usefulness of a model is determined by the accuracy of its predictions. A previous version of ECHO-T2DM was validated against actual trial outcomes and the model predictions were generally accurate. However, there have been recent upgrades to the model, which modify model predictions and necessitate an update of the validation exercises. The objectives of this study were to extend the methods available for evaluating model validity, to conduct a formal model validation of ECHO-T2DM (version 2.3.0) in accordance with the principles espoused by the International Society for Pharmacoeconomics and Outcomes Research (ISPOR) and the Society for Medical Decision Making (SMDM), and secondarily to evaluate the relative accuracy of four sets of macrovascular risk equations included in ECHO-T2DM. We followed the ISPOR/SMDM guidelines on model validation, evaluating face validity, verification, cross-validation, and external validation. Model verification involved 297 'stress tests', in which specific model inputs were modified systematically to ascertain correct model implementation. Cross-validation consisted of a comparison between ECHO-T2DM predictions and those of the seminal National Institutes of Health model. In external validation, study characteristics were entered into ECHO-T2DM to replicate the clinical results of 12 studies (including 17 patient populations), and model predictions were compared to observed values using established statistical techniques as well as measures of average prediction error, separately for the four sets of macrovascular risk equations supported in ECHO-T2DM. Sub-group analyses were conducted for dependent vs. independent outcomes and for microvascular vs. macrovascular vs. mortality endpoints. All stress tests were passed. ECHO-T2DM replicated the National Institutes of Health cost-effectiveness application with numerically similar results. In external validation of ECHO-T2DM, model predictions agreed well with observed clinical outcomes. For all sets of macrovascular risk equations, the results were close to the intercept and slope coefficients corresponding to a perfect match, resulting in high R 2 and failure to reject concordance using an F test. The results were similar for sub-groups of dependent and independent validation, with some degree of under-prediction of macrovascular events. ECHO-T2DM continues to match health outcomes in clinical trials in T2DM, with prediction accuracy similar to other leading models of T2DM.
Projected Impact of Compositional Verification on Current and Future Aviation Safety Risk
NASA Technical Reports Server (NTRS)
Reveley, Mary S.; Withrow, Colleen A.; Leone, Karen M.; Jones, Sharon M.
2014-01-01
The projected impact of compositional verification research conducted by the National Aeronautic and Space Administration System-Wide Safety and Assurance Technologies on aviation safety risk was assessed. Software and compositional verification was described. Traditional verification techniques have two major problems: testing at the prototype stage where error discovery can be quite costly and the inability to test for all potential interactions leaving some errors undetected until used by the end user. Increasingly complex and nondeterministic aviation systems are becoming too large for these tools to check and verify. Compositional verification is a "divide and conquer" solution to addressing increasingly larger and more complex systems. A review of compositional verification research being conducted by academia, industry, and Government agencies is provided. Forty-four aviation safety risks in the Biennial NextGen Safety Issues Survey were identified that could be impacted by compositional verification and grouped into five categories: automation design; system complexity; software, flight control, or equipment failure or malfunction; new technology or operations; and verification and validation. One capability, 1 research action, 5 operational improvements, and 13 enablers within the Federal Aviation Administration Joint Planning and Development Office Integrated Work Plan that could be addressed by compositional verification were identified.
NASA Astrophysics Data System (ADS)
Łapka, Piotr; Furmański, Piotr
2018-04-01
The paper presents verification and validation of an advanced numerical model of heat and moisture transfer in the multi-layer protective clothing and in components of the experimental stand subjected to either high surroundings temperature or high radiative heat flux emitted by hot objects. The developed model included conductive-radiative heat transfer in the hygroscopic porous fabrics and air gaps as well as conductive heat transfer in components of the stand. Additionally, water vapour diffusion in the pores and air spaces as well as phase transition of the bound water in the fabric fibres (sorption and desorption) were accounted for. All optical phenomena at internal or external walls were modelled and the thermal radiation was treated in the rigorous way, i.e., semi-transparent absorbing, emitting and scattering fabrics with the non-grey properties were assumed. The air was treated as transparent. Complex energy and mass balances as well as optical conditions at internal or external interfaces were formulated in order to find values of temperatures, vapour densities and radiation intensities at these interfaces. The obtained highly non-linear coupled system of discrete equations was solved by the Finite Volume based in-house iterative algorithm. The developed model passed discretisation convergence tests and was successfully verified against the results obtained applying commercial software for simplified cases. Then validation was carried out using experimental measurements collected during exposure of the protective clothing to high radiative heat flux emitted by the IR lamp. Satisfactory agreement of simulated and measured temporal variation of temperature at external and internal surfaces of the multi-layer clothing was attained.
Description of a Website Resource for Turbulence Modeling Verification and Validation
NASA Technical Reports Server (NTRS)
Rumsey, Christopher L.; Smith, Brian R.; Huang, George P.
2010-01-01
The activities of the Turbulence Model Benchmarking Working Group - which is a subcommittee of the American Institute of Aeronautics and Astronautics (AIAA) Fluid Dynamics Technical Committee - are described. The group s main purpose is to establish a web-based repository for Reynolds-averaged Navier-Stokes turbulence model documentation, including verification and validation cases. This turbulence modeling resource has been established based on feedback from a survey on what is needed to achieve consistency and repeatability in turbulence model implementation and usage, and to document and disseminate information on new turbulence models or improvements to existing models. The various components of the website are described in detail: description of turbulence models, turbulence model readiness rating system, verification cases, validation cases, validation databases, and turbulence manufactured solutions. An outline of future plans of the working group is also provided.
Space Shuttle external tank: Today - DDT & E: Tomorrow - Production
NASA Technical Reports Server (NTRS)
Norton, A. M.; Tanner, E. J.
1979-01-01
The External Tank (ET) is the structural backbone of the Space Shuttle. The ET is discussed relative to its role; its design as a highly efficient Shuttle element; the liquid oxygen tank - a thin shelled monocoque; the intertank - the forward structural connection; the liquid hydrogen tank structure - the connection with the Orbiter; the ET structural verification; the propulsion system - a variety of functions; the electrical subsystem; electrical subsystem qualification; the thermal protection system; and other related problems. To date the qualification programs have been extremely successful and are almost complete, and the first flight tank has been delivered. Tomorrow's objectives will concentrate on establishing the facilities, tools and processes to achieve a production rate of 24 ETs/year.
Rule groupings: An approach towards verification of expert systems
NASA Technical Reports Server (NTRS)
Mehrotra, Mala
1991-01-01
Knowledge-based expert systems are playing an increasingly important role in NASA space and aircraft systems. However, many of NASA's software applications are life- or mission-critical and knowledge-based systems do not lend themselves to the traditional verification and validation techniques for highly reliable software. Rule-based systems lack the control abstractions found in procedural languages. Hence, it is difficult to verify or maintain such systems. Our goal is to automatically structure a rule-based system into a set of rule-groups having a well-defined interface to other rule-groups. Once a rule base is decomposed into such 'firewalled' units, studying the interactions between rules would become more tractable. Verification-aid tools can then be developed to test the behavior of each such rule-group. Furthermore, the interactions between rule-groups can be studied in a manner similar to integration testing. Such efforts will go a long way towards increasing our confidence in the expert-system software. Our research efforts address the feasibility of automating the identification of rule groups, in order to decompose the rule base into a number of meaningful units.
EPA GROUP VERIFIES PERFORMANCE OF GREENHOUSE GAS EMISSIONS-MITIGATION TECHNOLOGIES
The Greenhouse Gas Technology Verification Center (the Center) is one of 12 independently operated environmental technology verification organizations established by the U.S. Environmental Protection Agency (EPA). The Center provides third-party performance data to industry and o...
[The Dose Effect of Isocenter Selection during IMRT Dose Verification with the 2D Chamber Array].
Xie, Chuanbin; Cong, Xiaohu; Xu, Shouping; Dai, Xiangkun; Wang, Yunlai; Han, Lu; Gong, Hanshun; Ju, Zhongjian; Ge, Ruigang; Ma, Lin
2015-03-01
To investigate the dose effect of isocenter difference during IMRT dose verification with the 2D chamber array. The samples collected from 10 patients were respectively designed for IMRT plans, the isocenter of which was independently defined as P(o), P(x) and P(y). P(o) was fixed on the target center and the other points shifted 8cm from the target center in the orientation of x/y. The PTW729 was used for 2D dose verification in the 3 groups which beams of plans were set to 0 degrees. The γ-analysis passing rates for the whole plan and each beam were gotten using the different standards in the 3 groups, The results showed the mean passing rate of γ-analysis was highest in the P(o) group, and the mean passing rate of the whole plan was better than that of each beam. In addition, it became worse with the increase of dose leakage between the leaves in P(y) group. Therefore, the determination of isocenter has a visible effect for IMRT dose verification of the 2D chamber array, The isocenter of the planning design should be close to the geometric center of target.
2015-06-01
adequate documentation to substantiate transactions , and effective internal controls surrounding business processes along with the verification that...organization, such as its personnel, processes, and objectives. The internal auditing profession brings a composite of in-depth knowledge and best business ...with internal auditors. Organizations should keep internal auditors abreast of changes in expectations as the business evolves. Doing so helps
External Verification of SCADA System Embedded Controller Firmware
2012-03-01
microprocessor and read-only memory (ROM) or flash memory for storing firmware and control logic [5],[8]. A PLC typically has three software levels as shown in...implementing different firmware. Because PLCs are in effect a microprocessor device, an analysis of the current research on embedded devices is important...Electronics Engineers (IEEE) published a 15 best practices guide for firmware control on microprocessors [44]. IEEE suggests that microprocessors
Exact Magnetic Diffusion Solutions for Magnetohydrodynamic Code Verification
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, D S
In this paper, the authors present several new exact analytic space and time dependent solutions to the problem of magnetic diffusion in R-Z geometry. These problems serve to verify several different elements of an MHD implementation: magnetic diffusion, external circuit time integration, current and voltage energy sources, spatially dependent conductivities, and ohmic heating. The exact solutions are shown in comparison with 2D simulation results from the Ares code.
The study of thermal processes in control systems of heat consumption of buildings
NASA Astrophysics Data System (ADS)
Tsynaeva, E.; A, Tsynaeva
2017-11-01
The article discusses the main thermal processes in the automated control systems for heat consumption (ACSHC) of buildings, schematic diagrams of these systems, mathematical models used for description of thermal processes in ACSHC. Conducted verification represented by mathematical models. It was found that the efficiency of the operation of ACSHC depend from the external and internal factors. Numerical study of dynamic modes of operation of ACSHC.
STS-96 crew takes part in payload Interface Verification Test
NASA Technical Reports Server (NTRS)
1999-01-01
In the SPACEHAB Facility, the STS-96 crew looks at equipment as part of a payload Interface Verification Test (IVT) for their upcoming mission to the International Space Station . From left are Mission Specialist Ellen Ochoa (behind the opened storage cover ), Commander Kent Rominger, Pilot Rick Husband (holding a lithium hydroxide canister) and Mission Specialists Dan Barry, Valery Tokarev of Russia and Julie Payette. In the background is TTI interpreter Valentina Maydell. The other crew member at KSC for the IVT is Mission Specialist Tamara Jernigan. Mission STS-96 carries the SPACEHAB Logistics Double Module, which has equipment to further outfit the International Space Station service module and equipment that can be off-loaded from the early U.S. assembly flights. The SPACEHAB carries internal logistics and resupply cargo for station outfitting, plus an external Russian cargo crane to be mounted to the exterior of the Russian station segment and used to perform space walking maintenance activities. The double module stowage provides capacity of up to 10,000 lbs. with the ability to accommodate powered payloads, four external rooftop stowage locations, four double-rack locations (two powered), up to 61 bulkhead-mounted middeck locker locations, and floor storage for large unique items and Soft Stowage. STS-96 is targeted to launch May 20 about 9:32 a.m.
STS-96 crew takes part in payload Interface Verification Test
NASA Technical Reports Server (NTRS)
1999-01-01
In the SPACEHAB Facility, STS-96 crew members look over equipment during a payload Interface Verification Test (IVT) for their upcoming mission to the International Space Station. From left are Khristal Parker, with Boeing; Mission Specialist Dan Barry, Pilot Rick Husband, Mission Specialist Tamara Jernigan, and at the far right, Mission Specialist Julie Payette. An unidentified worker is in the background. Also at KSC for the IVT are Commander Kent Rominger and Mission Specialists Ellen Ochoa and Valery Tokarev of Russia. Mission STS-96 carries the SPACEHAB Logistics Double Module, which will have equipment to further outfit the International Space Station service module and equipment that can be off-loaded from the early U.S. assembly flights. It carries internal logistics and resupply cargo for station outfitting, plus an external Russian cargo crane to be mounted to the exterior of the Russian station segment and used to perform space walking maintenance activities. The double module stowage provides capacity of up to 10,000 lbs. with the ability to accommodate powered payloads, four external rooftop stowage locations, four double-rack locations (two powered), up to 61 bulkhead-mounted middeck locker locations, and floor storage for large unique items and Soft Stowage. STS-96 is targeted to launch May 20 about 9:32 a.m.
STS-96 crew takes part in payload Interface Verification Test
NASA Technical Reports Server (NTRS)
1999-01-01
In the SPACEHAB Facility, (left to right) STS-96 Pilot Rick Husband and Mission Specialists Julie Payette and Ellen Ochoa work the straps on the Sequential Shunt Unit (SSU) in front of them. The STS-96 crew is at KSC for a payload Interface Verification Test (IVT) for its upcoming mission to the International Space Station . Other crew members at KSC for the IVT are Commander Kent Rominger and Mission Specialists Tamara Jernigan, Dan Barry and Valery Tokarev of Russia. The SSU is part of the cargo on Mission STS-96, which carries the SPACEHAB Logistics Double Module, with equipment to further outfit the International Space Station service module and equipment that can be off-loaded from the early U.S. assembly flights. The SPACEHAB carries internal logistics and resupply cargo for station outfitting, plus an external Russian cargo crane to be mounted to the exterior of the Russian station segment and used to perform space walking maintenance activities. The double module stowage provides capacity of up to 10,000 lbs. with the ability to accommodate powered payloads, four external rooftop stowage locations, four double-rack locations (two powered), up to 61 bulkhead-mounted middeck locker locations, and floor storage for large unique items and Soft Stowage. STS-96 is targeted to launch May 20 about 9:32 a.m.
STS-96 crew takes part in payload Interface Verification Test
NASA Technical Reports Server (NTRS)
1999-01-01
In the SPACEHAB Facility, STS-96 Mission Specialist Valery Tokarev of Russia (left) and Commander Kent Rominger (second from right) listen to Lynn Ashby (far right), with JSC, talking about the SPACEHAB equipment in front of them during a payload Interface Verification Test (IVT). In the background behind Tokarev is TTI interpreter Valentina Maydell. Other STS-96 crew members at KSC for the IVT are Pilot Rick Husband and Mission Specialists Dan Barry, Ellen Ochoa, Tamara Jernigan and Julie Payette. Mission STS-96 carries the SPACEHAB Logistics Double Module, which will have equipment to further outfit the International Space Station service module and equipment that can be off-loaded from the early U.S. assembly flights. It carries internal logistics and resupply cargo for station outfitting, plus an external Russian cargo crane to be mounted to the exterior of the Russian station segment and used to perform space walking maintenance activities. The double module stowage provides capacity of up to 10,000 lbs. with the ability to accommodate powered payloads, four external rooftop stowage locations, four double-rack locations (two powered), up to 61 bulkhead-mounted middeck locker locations, and floor storage for large unique items and Soft Stowage. STS-96 is targeted to launch May 20 about 9:32 a.m.
STS-96 crew takes part in payload Interface Verification Test
NASA Technical Reports Server (NTRS)
1999-01-01
During a payload Interface Verification Test (IVT) in the SPACEHAB Facility, STS-96 Mission Specialist Valery Tokarev of Russia (second from left) and Commander Kent Rominger learn about the Sequential Shunt Unit (SSU) in front of them from Lynn Ashby (far right), with Johnson Space Center. At the far left looking on is TTI interpreter Valentina Maydell. Other crew members at KSC for the IVT are Pilot Rick Husband and Mission Specialists Ellen Ochoa, Tamara Jernigan, Dan Barry and Julie Payette. The SSU is part of the cargo on Mission STS-96, which carries the SPACEHAB Logistics Double Module, with equipment to further outfit the International Space Station service module and equipment that can be off-loaded from the early U.S. assembly flights. The SPACEHAB carries internal logistics and resupply cargo for station outfitting, plus an external Russian cargo crane to be mounted to the exterior of the Russian station segment and used to perform space walking maintenance activities. The double module stowage provides capacity of up to 10,000 lbs. with the ability to accommodate powered payloads, four external rooftop stowage locations, four double-rack locations (two powered), up to 61 bulkhead-mounted middeck locker locations, and floor storage for large unique items and Soft Stowage. STS-96 is targeted to launch May 20 about 9:32 a.m.
STS-96 crew takes part in payload Interface Verification Test
NASA Technical Reports Server (NTRS)
1999-01-01
In the SPACEHAB Facility, STS-96 Mission Specialist Valery Tokarev (in foreground) of the Russian Space Agency closes a container, part of the equipment that will be in the SPACEHAB module on mission STS-96. Behind Tokarev are Pilot Rick Husband (left) and Mission Specialist Dan Barry (right). Other crew members at KSC for a payload Interface Verification Test for the upcoming mission to the International Space Station are Commander Kent Rominger and Mission Specialists Ellen Ochoa, Tamara Jernigan and Julie Payette. Mission STS-96 carries the SPACEHAB Logistics Double Module, which has equipment to further outfit the International Space Station service module and equipment that can be off-loaded from the early U.S. assembly flights. The SPACEHAB carries internal logistics and resupply cargo for station outfitting, plus an external Russian cargo crane to be mounted to the exterior of the Russian station segment and used to perform space walking maintenance activities. The double module stowage provides capacity of up to 10,000 lbs. with the ability to accommodate powered payloads, four external rooftop stowage locations, four double-rack locations (two powered), up to 61 bulkhead-mounted middeck locker locations, and floor storage for large unique items and Soft Stowage. STS-96 is targeted to launch May 20 about 9:32 a.m.
STS-96 crew takes part in payload Interface Verification Test
NASA Technical Reports Server (NTRS)
1999-01-01
During a payload Interface Verification Test (IVT) in the SPACEHAB Facility, STS-96 Mission Specialist Tamara Jernigan checks over instructions while Mission Specialist Dan Barry looks up from the Sequential Shunt Unit (SSU) in front of him to other equipment Lynn Ashby (right), with Johnson Space Center, is pointing at. Other crew members at KSC for the IVT are Commander Kent Rominger, Pilot Rick Husband, and Mission Specialists Ellen Ochoa, Julie Payette and Valery Tokarev of Russia. The SSU is part of the cargo on Mission STS-96, which carries the SPACEHAB Logistics Double Module, with equipment to further outfit the International Space Station service module and equipment that can be off-loaded from the early U.S. assembly flights. The SPACEHAB carries internal logistics and resupply cargo for station outfitting, plus an external Russian cargo crane to be mounted to the exterior of the Russian station segment and used to perform space walking maintenance activities. The double module stowage provides capacity of up to 10,000 lbs. with the ability to accommodate powered payloads, four external rooftop stowage locations, four double-rack locations (two powered), up to 61 bulkhead-mounted middeck locker locations, and floor storage for large unique items and Soft Stowage. STS-96 is targeted to launch May 20 about 9:32 a.m.
STS-96 crew takes part in payload Interface Verification Test
NASA Technical Reports Server (NTRS)
1999-01-01
During a payload Interface Verification Test (IVT) in the SPACEHAB Facility, STS-96 Pilot Rick Husband and Mission Specialist Ellen Ochoa (on the left) and Mission Specialist Julie Payette (on the far right) listen to Khristal Parker (second from right), with Boeing, explain about the equipment in front of them. Other crew members at KSC for the IVT are Commander Kent Rominger and Mission Specialists Tamara Jernigan, Dan Barry and Valery Tokarev of Russia. The SSU is part of the cargo on Mission STS-96, which carries the SPACEHAB Logistics Double Module, with equipment to further outfit the International Space Station service module and equipment that can be off-loaded from the early U.S. assembly flights. The SPACEHAB carries internal logistics and resupply cargo for station outfitting, plus an external Russian cargo crane to be mounted to the exterior of the Russian station segment and used to perform space walking maintenance activities. The double module stowage provides capacity of up to 10,000 lbs. with the ability to accommodate powered payloads, four external rooftop stowage locations, four double-rack locations (two powered), up to 61 bulkhead-mounted middeck locker locations, and floor storage for large unique items and Soft Stowage. STS-96 is targeted to launch May 20 about 9:32 a.m.
STS-96 crew takes part in payload Interface Verification Test
NASA Technical Reports Server (NTRS)
1999-01-01
In the SPACEHAB Facility for a payload Interface Verification Test (IVT) for their upcoming mission to the International Space Station are (kneeling) STS-96 Mission Specialists Julie Payette and Ellen Ochoa, Pilot Rick Husband, and (standing at right) Mission Specialist Dan Barry. At the left is James Behling, with Boeing, explaining some of the equipment that will be on board STS-96. Other STS-96 crew members at KSC for the IVT are Commander Kent Rominger and Mission Specialists Tamara Jernigan and Valery Tokarev of Russia. Mission STS-96 carries the SPACEHAB Logistics Double Module, which will have equipment to further outfit the International Space Station service module and equipment that can be off-loaded from the early U.S. assembly flights. It carries internal logistics and resupply cargo for station outfitting, plus an external Russian cargo crane to be mounted to the exterior of the Russian station segment and used to perform space walking maintenance activities. The double module stowage provides capacity of up to 10,000 lbs. with the ability to accommodate powered payloads, four external rooftop stowage locations, four double-rack locations (two powered), up to 61 bulkhead-mounted middeck locker locations, and floor storage for large unique items and Soft Stowage. STS-96 is targeted to launch May 20 about 9:32 a.m.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carlson, J.J.; Bouchard, A.M.; Osbourn, G.C.
Future generation automated human biometric identification and verification will require multiple features/sensors together with internal and external information sources to achieve high performance, accuracy, and reliability in uncontrolled environments. The primary objective of the proposed research is to develop a theoretical and practical basis for identifying and verifying people using standoff biometric features that can be obtained with minimal inconvenience during the verification process. The basic problem involves selecting sensors and discovering features that provide sufficient information to reliably verify a person`s identity under the uncertainties caused by measurement errors and tactics of uncooperative subjects. A system was developed formore » discovering hand, face, ear, and voice features and fusing them to verify the identity of people. The system obtains its robustness and reliability by fusing many coarse and easily measured features into a near minimal probability of error decision algorithm.« less
Using Concept Space to Verify Hyponymy in Building a Hyponymy Lexicon
NASA Astrophysics Data System (ADS)
Liu, Lei; Zhang, Sen; Diao, Lu Hong; Yan, Shu Ying; Cao, Cun Gen
Verification of hyponymy relations is a basic problem in knowledge acquisition. We present a method of hyponymy verification based on concept space. Firstly, we give the definition of concept space about a group of candidate hyponymy relations. Secondly we analyze the concept space and define a set of hyponymy features based on the space structure. Then we use them to verify candidate hyponymy relations. Experimental results show that the method can provide adequate verification of hyponymy.
Adamczewski, Zbigniew; Chwałkiewicz, Michał; Lewiński, Andrzej; Brzeziński, Jan; Dedecjus, Marek
2015-01-01
Recently, intraoperative neurophysiological neuromonitoring (IONM) of recurrent laryngeal nerves (RLN) has been evolving quickly. This evolution touched many aspects of the technique, leading to continuous stimulation of the RLN with real time analysis of the electrical signal. The aim of the study was to estimate the value of continuous intraoperative neuromonitoring (CIONM) as the only technique for intraoperative neuromonitoring in thyroidectomy performed because of benign goitre. The study comprised 80 women qualified for thyroidectomy due to nodular goitre. The patients were divided into 4 groups depending on the technique used for RLN integrity verification: group 1 - thyroidectomy with CIONM; group 2 - thyroidectomy with direct, intermittent stimulation of RLN and vagus nerve (NX); group 3 - both CIONM and intermittent stimulation of RLN and NX; group 4 - thyroidectomy without any IONM. Mean operation time did not differ significantly among the groups with IONM, but was significantly longer in comparison to group 4, as well as the operation's cost. In the analysed groups there was no significant difference in complication ratio. CIONM with RLN visualization in thyroidectomy performed because of benign goitre is as safe as other methods of IONM and gives a continuous confirmation of the electrical integrity of the loop NX-RLN-vocal folds during almost the entire procedure. There is a clinical need for the development of external stimulation of NX (transdermal or trancranial), particularly for minimally invasive techniques in which access to NX is limited (i.e. transoral thyroidectomy).
Verification of eye lens dose in IMRT by MOSFET measurement.
Wang, Xuetao; Li, Guangjun; Zhao, Jianling; Song, Ying; Xiao, Jianghong; Bai, Sen
2018-04-17
The eye lens is recognized as one of the most radiosensitive structures in the human body. The widespread use of intensity-modulated radiotherapy (IMRT) complicates dose verification and necessitates high standards of dose computation. The purpose of this work was to assess the computed dose accuracy of eye lens through measurements using a metal-oxide-semiconductor field-effect transistor (MOSFET) dosimetry system. Sixteen clinical IMRT plans of head and neck patients were copied to an anthropomorphic head phantom. Measurements were performed using the MOSFET dosimetry system based on the head phantom. Two MOSFET detectors were imbedded in the eyes of the head phantom as the left and the right lens, covered by approximately 5-mm-thick paraffin wax. The measurement results were compared with the calculated values with a dose grid size of 1 mm. Sixteen IMRT plans were delivered, and 32 measured lens doses were obtained for analysis. The MOSFET dosimetry system can be used to verify the lens dose, and our measurements showed that the treatment planning system used in our clinic can provide adequate dose assessment in eye lenses. The average discrepancy between measurement and calculation was 6.7 ± 3.4%, and the largest discrepancy was 14.3%, which met the acceptability criterion set by the American Association of Physicists in Medicine Task Group 53 for external beam calculation for multileaf collimator-shaped fields in buildup regions. Copyright © 2018 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
Baghouse filtration products (BFPs) were evaluated by the Air Pollution Control Technology (APCT) pilot of the Environmental Technology Verification (ETV) Program. The performance factor verified was the mean outlet particle concentration for the filter fabric as a function of th...
Li, Zhijun; Ge, Shuzhi Sam; Liu, Sibang
2014-08-01
This paper investigates optimal feet forces' distribution and control of quadruped robots under external disturbance forces. First, we formulate a constrained dynamics of quadruped robots and derive a reduced-order dynamical model of motion/force. Consider an external wrench on quadruped robots; the distribution of required forces and moments on the supporting legs of a quadruped robot is handled as a tip-point force distribution and used to equilibrate the external wrench. Then, a gradient neural network is adopted to deal with the optimized objective function formulated as to minimize this quadratic objective function subjected to linear equality and inequality constraints. For the obtained optimized tip-point force and the motion of legs, we propose the hybrid motion/force control based on an adaptive neural network to compensate for the perturbations in the environment and approximate feedforward force and impedance of the leg joints. The proposed control can confront the uncertainties including approximation error and external perturbation. The verification of the proposed control is conducted using a simulation.
Yu, Su Jong; Jang, Eun Sun; Yu, Jiyoung; Cho, Geunhee; Yoon, Jung-Hwan; Kim, Youngsoo
2013-01-01
Hepatocellular carcinoma (HCC) is one of the most common and aggressive cancers and is associated with a poor survival rate. Clinically, the level of alpha-fetoprotein (AFP) has been used as a biomarker for the diagnosis of HCC. The discovery of useful biomarkers for HCC, focused solely on the proteome, has been difficult; thus, wide-ranging global data mining of genomic and proteomic databases from previous reports would be valuable in screening biomarker candidates. Further, multiple reaction monitoring (MRM), based on triple quadrupole mass spectrometry, has been effective with regard to high-throughput verification, complementing antibody-based verification pipelines. In this study, global data mining was performed using 5 types of HCC data to screen for candidate biomarker proteins: cDNA microarray, copy number variation, somatic mutation, epigenetic, and quantitative proteomics data. Next, we applied MRM to verify HCC candidate biomarkers in individual serum samples from 3 groups: a healthy control group, patients who have been diagnosed with HCC (Before HCC treatment group), and HCC patients who underwent locoregional therapy (After HCC treatment group). After determining the relative quantities of the candidate proteins by MRM, we compared their expression levels between the 3 groups, identifying 4 potential biomarkers: the actin-binding protein anillin (ANLN), filamin-B (FLNB), complementary C4-A (C4A), and AFP. The combination of 2 markers (ANLN, FLNB) improved the discrimination of the before HCC treatment group from the healthy control group compared with AFP. We conclude that the combination of global data mining and MRM verification enhances the screening and verification of potential HCC biomarkers. This efficacious integrative strategy is applicable to the development of markers for cancer and other diseases. PMID:23717429
Kim, Hyunsoo; Kim, Kyunggon; Yu, Su Jong; Jang, Eun Sun; Yu, Jiyoung; Cho, Geunhee; Yoon, Jung-Hwan; Kim, Youngsoo
2013-01-01
Hepatocellular carcinoma (HCC) is one of the most common and aggressive cancers and is associated with a poor survival rate. Clinically, the level of alpha-fetoprotein (AFP) has been used as a biomarker for the diagnosis of HCC. The discovery of useful biomarkers for HCC, focused solely on the proteome, has been difficult; thus, wide-ranging global data mining of genomic and proteomic databases from previous reports would be valuable in screening biomarker candidates. Further, multiple reaction monitoring (MRM), based on triple quadrupole mass spectrometry, has been effective with regard to high-throughput verification, complementing antibody-based verification pipelines. In this study, global data mining was performed using 5 types of HCC data to screen for candidate biomarker proteins: cDNA microarray, copy number variation, somatic mutation, epigenetic, and quantitative proteomics data. Next, we applied MRM to verify HCC candidate biomarkers in individual serum samples from 3 groups: a healthy control group, patients who have been diagnosed with HCC (Before HCC treatment group), and HCC patients who underwent locoregional therapy (After HCC treatment group). After determining the relative quantities of the candidate proteins by MRM, we compared their expression levels between the 3 groups, identifying 4 potential biomarkers: the actin-binding protein anillin (ANLN), filamin-B (FLNB), complementary C4-A (C4A), and AFP. The combination of 2 markers (ANLN, FLNB) improved the discrimination of the before HCC treatment group from the healthy control group compared with AFP. We conclude that the combination of global data mining and MRM verification enhances the screening and verification of potential HCC biomarkers. This efficacious integrative strategy is applicable to the development of markers for cancer and other diseases.
77 FR 291 - Agency Information Collection Activities: Proposed Collection; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-04
... Verification System (IEVS) Reporting and Supporting Regulations Contained in 42 CFR 431.17, 431.306, 435.910... verifications; Form Number: CMS-R-74 (OCN 0938-0467); Frequency: Monthly; Affected Public: State, Local, or..., issuers offering group health insurance coverage, and self-insured nonfederal governmental plans (through...
Baghouse filtration products (BFPs) were evaluated by the Air Pollution Control Technology (APCT) Verification Center. The performance factor verified was the mean outlet particle concentration for the filter fabric as a function of the size of those particles equal to and smalle...
Baghouse filtration products (BFPs) were evaluated by the Air Pollution Control Technology (APCT) Verification Center. The performance factor verified was the mean outlet particle concentration for the filter fabric as a function of the size of those particles equal to and smalle...
Design of an occulter testbed at flight Fresnel numbers
NASA Astrophysics Data System (ADS)
Sirbu, Dan; Kasdin, N. Jeremy; Kim, Yunjong; Vanderbei, Robert J.
2015-01-01
An external occulter is a spacecraft flown along the line-of-sight of a space telescope to suppress starlight and enable high-contrast direct imaging of exoplanets. Laboratory verification of occulter designs is necessary to validate the optical models used to design and predict occulter performance. At Princeton, we are designing and building a testbed that allows verification of scaled occulter designs whose suppressed shadow is mathematically identical to that of space occulters. Here, we present a sample design operating at a flight Fresnel number and is thus representative of a realistic space mission. We present calculations of experimental limits arising from the finite size and propagation distance available in the testbed, limitations due to manufacturing feature size, and non-ideal input beam. We demonstrate how the testbed is designed to be feature-size limited, and provide an estimation of the expected performance.
STS-96 crew takes part in payload Interface Verification Test
NASA Technical Reports Server (NTRS)
1999-01-01
In the SPACEHAB Facility, (from left) STS-96 Mission Specialist Julie Payette, Pilot Rick Husband and Mission Specialist Ellen Ochoa learn about the Sequential Shunt Unit (SSU) in front of them from Lynn Ashby (far right), with Johnson Space Center. The STS-96 crew is at KSC for a payload Interface Verification Test (IVT) for their upcoming mission to the International Space Station . Other crew members at KSC for the IVT are Commander Kent Rominger and Mission Specialists Tamara Jernigan, Dan Barry and Valery Tokarev of Russia. The SSU is part of the cargo on Mission STS-96, which carries the SPACEHAB Logistics Double Module, with equipment to further outfit the International Space Station service module and equipment that can be off-loaded from the early U.S. assembly flights. The SPACEHAB carries internal logistics and resupply cargo for station outfitting, plus an external Russian cargo crane to be mounted to the exterior of the Russian station segment and used to perform space walking maintenance activities. The double module stowage provides capacity of up to 10,000 lbs. with the ability to accommodate powered payloads, four external rooftop stowage locations, four double-rack locations (two powered), up to 61 bulkhead-mounted middeck locker locations, and floor storage for large unique items and Soft Stowage. STS-96 is targeted to launch May 20 about 9:32 a.m.
The overall objective of the Environmental Testing and Verification Coatings and Coating Equipment Program is to verify pollution prevention and performance characteristics of coating technologies and make the results of the testing available to prospective coating technology use...
45 CFR 150.209 - Verification of exhaustion of remedies and contact with State officials.
Code of Federal Regulations, 2010 CFR
2010-10-01
... REQUIREMENTS RELATING TO HEALTH CARE ACCESS CMS ENFORCEMENT IN GROUP AND INDIVIDUAL INSURANCE MARKETS CMS... § 150.209 Verification of exhaustion of remedies and contact with State officials. If CMS receives a complaint or other information indicating that a State is failing to enforce HIPAA requirements, CMS...
Stress distribution in Co-Cr implant frameworks after laser or TIG welding.
de Castro, Gabriela Cassaro; de Araújo, Cleudmar Amaral; Mesquita, Marcelo Ferraz; Consani, Rafael Leonardo Xediek; Nóbilo, Mauro Antônio de Arruda
2013-01-01
Lack of passivity has been associated with biomechanical problems in implant-supported prosthesis. The aim of this study was to evaluate the passivity of three techniques to fabricate an implant framework from a Co-Cr alloy by photoelasticity. The model was obtained from a steel die simulating an edentulous mandible with 4 external hexagon analog implants with a standard platform. On this model, five frameworks were fabricated for each group: a monoblock framework (control), laser and TIG welding frameworks. The photoelastic model was made from a flexible epoxy resin. On the photoelastic analysis, the frameworks were bolted onto the model for the verification of maximum shear stress at 34 selected points around the implants and 5 points in the middle of the model. The stresses were compared all over the photoelastic model, between the right, left, and center regions and between the cervical and apical regions. The values were subjected to two-way ANOVA, and Tukey's test (α=0.05). There was no significant difference among the groups and studied areas (p>0.05). It was concluded that the stresses generated around the implants were similar for all techniques.
Escobedo, Patricia; Cruz, Tess Boley; Tsai, Kai-Ya; Allem, Jon-Patrick; Soto, Daniel W; Kirkpatrick, Matthew G; Pattarroyo, Monica; Unger, Jennifer B
2017-09-11
Limited information exists about strategies and methods used on brand marketing websites to transmit pro-tobacco messages to tobacco users and potential users. This study compared age verification methods, themes, interactive activities and links to social media across tobacco brand websites. This study examined 12 tobacco brand websites representing four tobacco product categories: cigarettes, cigar/cigarillos, smokeless tobacco, and e-cigarettes. Website content was analyzed by tobacco product category and data from all website visits (n = 699) were analyzed. Adult smokers (n=32) coded websites during a one-year period, indicating whether or not they observed any of 53 marketing themes, seven interactive activities, or five external links to social media sites. Most (58%) websites required online registration before entering, however e-cigarette websites used click-through age verification. Compared to cigarette sites, cigar/cigarillo sites were more likely to feature themes related to "party" lifestyle, and e-cigarette websites were much more likely to feature themes related to harm reduction. Cigarette sites featured greater levels of interactive content compared to other tobacco products. Compared to cigarette sites, cigar/cigarillo sites were more likely to feature activities related to events and music. Compared to cigarette sites, both cigar and e-cigarette sites were more likely to direct visitors to external social media sites. Marketing methods and strategies normalize tobacco use by providing website visitors with positive themes combined with interactive content, and is an area of future research. Moreover, all tobacco products under federal regulatory authority should be required to use more stringent age verification gates. Findings indicate the Food and Drug Administration (FDA) should require brand websites of all tobacco products under its regulatory authority use more stringent age verification gates by requiring all visitors be at least 18 years of age and register online prior to entry. This is important given that marketing strategies may encourage experimentation with tobacco or deter quit attempts among website visitors. Future research should examine the use of interactive activities and social media on a wide variety of tobacco brand websites as interactive content is associated with more active information processing. © The Author 2017. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Murphy, Melissa M; Mazzocco, Michèle M M
2008-01-01
The present study focuses on math and related skills among 32 girls with fragile X (n = 14) or Turner (n = 18) syndrome during late elementary school. Performance in each syndrome group was assessed relative to Full Scale IQ-matched comparison groups of girls from the general population (n = 32 and n = 89 for fragile X syndrome and Turner syndrome, respectively). Differences between girls with fragile X and their comparison group emerged on untimed arithmetic calculations, mastery of counting skills, and arithmetic problem verification accuracy. Relative to girls in the comparison group, girls with Turner syndrome did not differ on untimed arithmetic calculations or problem verification accuracy, but they had limited mastery of counting skills and longer response times to complete the problem verification task. Girls with fragile X or Turner syndrome also differed from their respective comparison groups on math-related abilities, including visual-spatial, working memory, and reading skills, and the associations between math and those related skills. Together, these findings support the notion that difficulty with math and related skills among girls with fragile X or Turner syndrome continues into late elementary school and that the profile of math and related skill difficulty distinguishes the two syndrome groups from each other.
Eaton, David J; Tyler, Justine; Backshall, Alex; Bernstein, David; Carver, Antony; Gasnier, Anne; Henderson, Julia; Lee, Jonathan; Patel, Rushil; Tsang, Yatman; Yang, Huiqi; Zotova, Rada; Wells, Emma
2017-03-01
External dosimetry audits give confidence in the safe and accurate delivery of radiotherapy. The RTTQA group have performed an on-site audit programme for trial recruiting centres, who have recently implemented static or rotational IMRT, and those with major changes to planning or delivery systems. Measurements of reference beam output were performed by the host centre, and by the auditor using independent equipment. Verification of clinical plans was performed using the ArcCheck helical diode array. A total of 54 measurement sessions were performed between May 2014 and June 2016 at 28 UK institutions, reflecting the different combinations of planning and delivery systems used at each institution. Average ratio of measured output between auditor and host was 1.002±0.006. Average point dose agreement for clinical plans was -0.3±1.8%. Average (and 95% lower confidence intervals) of gamma pass rates at 2%/2mm, 3%/2mm and 3%/3mm respectively were: 92% (80%), 96% (90%) and 98% (94%). Moderately significant differences were seen between fixed gantry angle and rotational IMRT, and between combination of planning systems and linac manufacturer, but not between anatomical treatment site or beam energy. An external audit programme has been implemented for universal and efficient credentialing of IMRT treatments in clinical trials. Good agreement was found between measured and expected doses, with few outliers, leading to a simple table of optimal and mandatory tolerances for approval of dosimetry audit results. Feedback was given to some centres leading to improved clinical practice. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Code of Federal Regulations, 2010 CFR
2010-04-01
... and the vesting conditions, (v) The medium of funding (e. g., self-insured, unit purchase group... source and application in sufficient detail to permit ready analysis and verification thereof, and, in... verification of the reasonableness thereof. (9) A statement of the contributions paid under the plan for the...
TH-A-BRC-00: New Task Groups for External Beam QA: An Overview
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
2016-06-15
AAPM TG-135U1 QA for Robotic Radiosurgery - Sonja Dieterich Since the publication of AAPM TG-135 in 2011, the technology of robotic radiosurgery has rapidly developed. AAPM TG-135U1 will provide recommendations on the clinical practice for using the IRIS collimator, fiducial-less real-time motion tracking, and Monte Carlo based treatment planning. In addition, it will summarize currently available literature about uncertainties. Learning Objectives: Understand the progression of technology since the first TG publication Learn which new QA procedures should be implemented for new technologies Be familiar with updates to clinical practice guidelines AAPM TG-178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance -more » Steven Goetsch Purpose: AAPM Task Group 178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance was formed in August, 2008. The Task Group has 12 medical physicists, two physicians and two consultants. Methods: A round robin dosimetry intercomparison of proposed ionization chambers, electrometer and dosimetry phantoms was conducted over a 15 month period in 2011 and 2012 (Med Phys 42, 11, Nov, 2015). The data obtained at 9 institutions (with ten different Elekta Gamma Knife units) was analyzed by the lead author using several protocols. Results: The most consistent results were obtained using the Elekta ABS 16cm diameter phantom, with the TG-51 protocol modified as recommended by Alfonso et al (Med Phys 35, 11, Nov 2008). A key white paper (Med Phys, in press) sponsored by Elekta Corporation, was used to obtain correction factors for the ionization chambers and phantoms used in this intercomparison. Consistent results were obtained for both Elekta Gamma Knife Model 4C and Gamma Knife Perfexion units as measured with each of two miniature ionization chambers. Conclusion: The full report gives clinical history and background of gamma stereotactic radiosurgery, clinical examples and history, quality assurance recommendations and outline of possible dosimetry protocols. The report will be reviewed by the AAPM Working Group on Recommendations for Radiotherapy External Beam Quality Assurance and then by the AAPM Science Council before publication in Medical Physics Survey of possible calibration protocols for calibration of Gamma Stereotactic Radiosurgery (GSR) devices Overview of modern Quality Assurance techniques for GSR AAPM TG-218 Tolerance Levels and Methodologies for IMRT Verification QA - Moyed Miften Patient-specific IMRT QA measurement is a process designed to identify discrepancies between calculated and delivered doses. Error tolerance limits are not well-defined or consistently applied across centers. The AAPM TG-218 report has been prepared to improve the understanding and consistency of this process by providing recommendations for methodologies and tolerance limits in patient-specific IMRT QA. Learning Objectives: Review measurement methods and methodologies for absolute dose verification Provide recommendations on delivery methods, data interpretation, the use of analysis routines and choice of tolerance limits for IMRT QA Sonja Dieterich has a research agreement with Sun Nuclear Inc. Steven Goetsch is a part-time consultant for Elekta.« less
Hejl, H.R.
1989-01-01
The precipitation-runoff modeling system was applied to the 8.21 sq-mi drainage area of the Ah-shi-sle-pah Wash watershed in northwestern New Mexico. The calibration periods were May to September of 1981 and 1982, and the verification period was May to September 1983. Twelve storms were available for calibration and 8 storms were available for verification. For calibration A (hydraulic conductivity estimated from onsite data and other storm-mode parameters optimized), the computed standard error of estimate was 50% for runoff volumes and 72% of peak discharges. Calibration B included hydraulic conductivity in the optimization, which reduced the standard error of estimate to 28 % for runoff volumes and 50% for peak discharges. Optimized values for hydraulic conductivity resulted in reductions from 1.00 to 0.26 in/h and 0.20 to 0.03 in/h for the 2 general soils groups in the calibrations. Simulated runoff volumes using 7 of 8 storms occurring during the verification period had a standard error of estimate of 40% for verification A and 38% for verification B. Simulated peak discharge had a standard error of estimate of 120% for verification A and 56% for verification B. Including the eighth storm which had a relatively small magnitude in the verification analysis more than doubled the standard error of estimating volumes and peaks. (USGS)
Verification of the proteus two-dimensional Navier-Stokes code for flat plate and pipe flows
NASA Technical Reports Server (NTRS)
Conley, Julianne M.; Zeman, Patrick L.
1991-01-01
The Proteus Navier-Stokes Code is evaluated for 2-D/axisymmetric, viscous, incompressible, internal, and external flows. The particular cases to be discussed are laminar and turbulent flows over a flat plate, laminar and turbulent developing pipe flows, and turbulent pipe flow with swirl. Results are compared with exact solutions, empirical correlations, and experimental data. A detailed description of the code set-up, including boundary conditions, initial conditions, grid size, and grid packing is given for each case.
Numerical simulation of an elastic structure behavior under transient fluid flow excitation
NASA Astrophysics Data System (ADS)
Afanasyeva, Irina N.; Lantsova, Irina Yu.
2017-01-01
This paper deals with the verification of a numerical technique of modeling fluid-structure interaction (FSI) problems. The configuration consists of incompressible viscous fluid around an elastic structure in the channel. External flow is laminar. Multivariate calculations are performed using special software ANSYS CFX and ANSYS Mechanical. Different types of parameters of mesh deformation and solver controls (time step, under relaxation factor, number of iterations at coupling step) were tested. The results are presented in tables and plots in comparison with reference data.
External tank aerothermal design criteria verification
NASA Technical Reports Server (NTRS)
Praharaj, Sarat C.; Saladino, Anthony J.
1991-01-01
If a Space Shuttle Main Engine (SSME) fails during the initial 160 seconds of the Shuttle flight, a return-to-launch-site maneuver will be implemented. The period of concern for this task is the pitch-around maneuver when the vehicle is flying backward. The intent of this report is to identify and define the flowfield at the most critical locations from an environment perspective. The solution procedure used to predict the plume heating rates involves both computational analysis and engineering modeling.
Geiss, S; Einax, J W
2001-07-01
Detection limit, reporting limit and limit of quantitation are analytical parameters which describe the power of analytical methods. These parameters are used for internal quality assurance and externally for competing, especially in the case of trace analysis in environmental compartments. The wide variety of possibilities for computing or obtaining these measures in literature and in legislative rules makes any comparison difficult. Additionally, a host of terms have been used within the analytical community to describe detection and quantitation capabilities. Without trying to create an order for the variety of terms, this paper is aimed at providing a practical proposal for answering the main questions for the analysts concerning quality measures above. These main questions and related parameters were explained and graphically demonstrated. Estimation and verification of these parameters are the two steps to get real measures. A rule for a practical verification is given in a table, where the analyst can read out what to measure, what to estimate and which criteria have to be fulfilled. In this manner verified parameters detection limit, reporting limit and limit of quantitation now are comparable and the analyst himself is responsible to the unambiguity and reliability of these measures.
First light of an external occulter testbed at flight Fresnel numbers
NASA Astrophysics Data System (ADS)
Kim, Yunjong; Sirbu, Dan; Hu, Mia; Kasdin, Jeremy; Vanderbei, Robert J.; Harness, Anthony; Shaklan, Stuart
2017-01-01
Many approaches have been suggested over the last couple of decades for imaging Earth-like planets. One of the main candidates for creating high-contrast for future Earth-like planets detection is an external occulter. The external occulter is a spacecraft flown along the line-of-sight of a space telescope to suppress starlight and enable high-contrast direct imaging of exoplanets. The occulter is typically tens of meters in diameter and the separation from the telescope is of the order of tens of thousands of kilometers. Optical testing of a full-scale external occulter on the ground is impossible because of the long separations. Therefore, laboratory verification of occulter designs is necessary to validate the optical models used to design and predict occulter performance. At Princeton, we have designed and built a testbed that allows verification of scaled occulter designs whose suppressed shadow is mathematically identical to that of space occulters. The goal of this experiment is to demonstrate a pupil plane suppression of better than 1e-9 with a corresponding image plane contrast of better than 1e-11. The occulter testbed uses a 77.2 m optical propagation distance to realize the flight Fresnel number of 14.5. The scaled mask is placed at 27.2 m from the artificial source and the camera is located 50.0 m from the scaled mask. We will use an etched silicon mask, manufactured by the Microdevices Lab(MDL) of the Jet Propulsion Laboratory(JPL), as the occulter. Based on conversations with MDL, we expect that 0.5 μm feature size is an achievable resolution in the mask manufacturing process and is therefore likely the indicator of the best possible performance. The occulter is illuminated by a diverging laser beam to reduce the aberrations from the optics before the occulter. Here, we present first light result of a sample design operating at a flight Fresnel number and the experimental setup of the testbed. We compare the experimental results with simulations that predict the ultimate contrast performance.
NASA Astrophysics Data System (ADS)
Kim, Kwang Hyeon; Lee, Suk; Shim, Jang Bo; Yang, Dae Sik; Yoon, Won Sup; Park, Young Je; Kim, Chul Yong; Cao, Yuan Jie; Chang, Kyung Hwan
2018-01-01
The aim of this study was to derive a new plan-scoring index using normal tissue complication probabilities to verify different plans in the selection of personalized treatment. Plans for 12 patients treated with tomotherapy were used to compare scoring for ranking. Dosimetric and biological indexes were analyzed for the plans for a clearly distinguishable group ( n = 7) and a similar group ( n = 12), using treatment plan verification software that we developed. The quality factor ( QF) of our support software for treatment decisions was consistent with the final treatment plan for the clearly distinguishable group (average QF = 1.202, 100% match rate, n = 7) and the similar group (average QF = 1.058, 33% match rate, n = 12). Therefore, we propose a normal tissue complication probability (NTCP) based on the plan scoring index for verification of different plans for personalized treatment-plan selection. Scoring using the new QF showed a 100% match rate (average NTCP QF = 1.0420). The NTCP-based new QF scoring method was adequate for obtaining biological verification quality and organ risk saving using the treatment-planning decision-support software we developed for prostate cancer.
Software engineering and automatic continuous verification of scientific software
NASA Astrophysics Data System (ADS)
Piggott, M. D.; Hill, J.; Farrell, P. E.; Kramer, S. C.; Wilson, C. R.; Ham, D.; Gorman, G. J.; Bond, T.
2011-12-01
Software engineering of scientific code is challenging for a number of reasons including pressure to publish and a lack of awareness of the pitfalls of software engineering by scientists. The Applied Modelling and Computation Group at Imperial College is a diverse group of researchers that employ best practice software engineering methods whilst developing open source scientific software. Our main code is Fluidity - a multi-purpose computational fluid dynamics (CFD) code that can be used for a wide range of scientific applications from earth-scale mantle convection, through basin-scale ocean dynamics, to laboratory-scale classic CFD problems, and is coupled to a number of other codes including nuclear radiation and solid modelling. Our software development infrastructure consists of a number of free tools that could be employed by any group that develops scientific code and has been developed over a number of years with many lessons learnt. A single code base is developed by over 30 people for which we use bazaar for revision control, making good use of the strong branching and merging capabilities. Using features of Canonical's Launchpad platform, such as code review, blueprints for designing features and bug reporting gives the group, partners and other Fluidity uers an easy-to-use platform to collaborate and allows the induction of new members of the group into an environment where software development forms a central part of their work. The code repositoriy are coupled to an automated test and verification system which performs over 20,000 tests, including unit tests, short regression tests, code verification and large parallel tests. Included in these tests are build tests on HPC systems, including local and UK National HPC services. The testing of code in this manner leads to a continuous verification process; not a discrete event performed once development has ceased. Much of the code verification is done via the "gold standard" of comparisons to analytical solutions via the method of manufactured solutions. By developing and verifying code in tandem we avoid a number of pitfalls in scientific software development and advocate similar procedures for other scientific code applications.
Houck, Constance S; Deshpande, Jayant K; Flick, Randall P
2017-06-01
The Task Force for Children's Surgical Care, an ad-hoc multidisciplinary group of invited leaders in pediatric perioperative medicine, was assembled in May 2012 to consider approaches to optimize delivery of children's surgical care in today's competitive national healthcare environment. Over the subsequent 3 years, with support from the American College of Surgeons (ACS) and Children's Hospital Association (CHA), the group established principles regarding perioperative resource standards, quality improvement and safety processes, data collection, and verification that were used to develop an ACS-sponsored Children's Surgery Verification and Quality Improvement Program (ACS CSV). The voluntary ACS CSV was officially launched in January 2017 and more than 125 pediatric surgical programs have expressed interest in verification. ACS CSV-verified programs have specific requirements for pediatric anesthesia leadership, resources, and the availability of pediatric anesthesiologists or anesthesiologists with pediatric expertise to care for infants and young children. The present review outlines the history of the ACS CSV, key elements of the program, and the standards specific to pediatric anesthesiology. As with the pediatric trauma programs initiated more than 40 years ago, this program has the potential to significantly improve surgical care for infants and children in the United States and Canada.
The Dutch surgical colorectal audit.
Van Leersum, N J; Snijders, H S; Henneman, D; Kolfschoten, N E; Gooiker, G A; ten Berge, M G; Eddes, E H; Wouters, M W J M; Tollenaar, R A E M; Bemelman, W A; van Dam, R M; Elferink, M A; Karsten, Th M; van Krieken, J H J M; Lemmens, V E P P; Rutten, H J T; Manusama, E R; van de Velde, C J H; Meijerink, W J H J; Wiggers, Th; van der Harst, E; Dekker, J W T; Boerma, D
2013-10-01
In 2009, the nationwide Dutch Surgical Colorectal Audit (DSCA) was initiated by the Association of Surgeons of the Netherlands (ASN) to monitor, evaluate and improve colorectal cancer care. The DSCA is currently widely used as a blueprint for the initiation of other audits, coordinated by the Dutch Institute for Clinical Auditing (DICA). This article illustrates key elements of the DSCA and results of three years of auditing. Key elements include: a leading role of the professional association with integration of the audit in the national quality assurance policy; web-based registration by medical specialists; weekly updated online feedback to participants; annual external data verification with other data sources; improvement projects. In two years, all Dutch hospitals participated in the audit. Case-ascertainment was 92% in 2010 and 95% in 2011. External data verification by comparison with the Netherlands Cancer Registry (NCR) showed high concordance of data items. Within three years, guideline compliance for diagnostics, preoperative multidisciplinary meetings and standardised reporting increased; complication-, re-intervention and postoperative mortality rates decreased significantly. The success of the DSCA is the result of effective surgical collaboration. The leading role of the ASN in conducting the audit resulted in full participation of all colorectal surgeons in the Netherlands. By integrating the audit into the ASNs' quality assurance policy, it could be used to set national quality standards. Future challenges include reduction of administrative burden; expansion to a multidisciplinary registration; and addition of financial information and patient reported outcomes to the audit data. Copyright © 2013 Elsevier Ltd. All rights reserved.
Automated analysis in generic groups
NASA Astrophysics Data System (ADS)
Fagerholm, Edvard
This thesis studies automated methods for analyzing hardness assumptions in generic group models, following ideas of symbolic cryptography. We define a broad class of generic and symbolic group models for different settings---symmetric or asymmetric (leveled) k-linear groups --- and prove ''computational soundness'' theorems for the symbolic models. Based on this result, we formulate a master theorem that relates the hardness of an assumption to solving problems in polynomial algebra. We systematically analyze these problems identifying different classes of assumptions and obtain decidability and undecidability results. Then, we develop automated procedures for verifying the conditions of our master theorems, and thus the validity of hardness assumptions in generic group models. The concrete outcome is an automated tool, the Generic Group Analyzer, which takes as input the statement of an assumption, and outputs either a proof of its generic hardness or shows an algebraic attack against the assumption. Structure-preserving signatures are signature schemes defined over bilinear groups in which messages, public keys and signatures are group elements, and the verification algorithm consists of evaluating ''pairing-product equations''. Recent work on structure-preserving signatures studies optimality of these schemes in terms of the number of group elements needed in the verification key and the signature, and the number of pairing-product equations in the verification algorithm. While the size of keys and signatures is crucial for many applications, another aspect of performance is the time it takes to verify a signature. The most expensive operation during verification is the computation of pairings. However, the concrete number of pairings is not captured by the number of pairing-product equations considered in earlier work. We consider the question of what is the minimal number of pairing computations needed to verify structure-preserving signatures. We build an automated tool to search for structure-preserving signatures matching a template. Through exhaustive search we conjecture lower bounds for the number of pairings required in the Type~II setting and prove our conjecture to be true. Finally, our tool exhibits examples of structure-preserving signatures matching the lower bounds, which proves tightness of our bounds, as well as improves on previously known structure-preserving signature schemes.
NASA Technical Reports Server (NTRS)
Hand, David W.; Crittenden, John C.; Ali, Anisa N.; Bulloch, John L.; Hokanson, David R.; Parrem, David L.
1996-01-01
This thesis includes the development and verification of an adsorption model for analysis and optimization of the adsorption processes within the International Space Station multifiltration beds. The fixed bed adsorption model includes multicomponent equilibrium and both external and intraparticle mass transfer resistances. Single solute isotherm parameters were used in the multicomponent equilibrium description to predict the competitive adsorption interactions occurring during the adsorption process. The multicomponent equilibrium description used the Fictive Component Analysis to describe adsorption in unknown background matrices. Multicomponent isotherms were used to validate the multicomponent equilibrium description. Column studies were used to develop and validate external and intraparticle mass transfer parameter correlations for compounds of interest. The fixed bed model was verified using a shower and handwash ersatz water which served as a surrogate to the actual shower and handwash wastewater.
van Pelt, Stijn; Derks, Roy; Matteucci, Marco; Hansen, Mikkel Fougt; Dietzel, Andreas
2011-04-01
A new concept for the manipulation of superparamagnetic beads inside a microfluidic chip is presented in this paper. The concept allows for bead actuation orthogonal to the flow direction inside a microchannel. Basic manipulation functionalities were studied by means of finite element simulations and results were oval-shaped steady state oscillations with bead velocities up to 500 μm/s. The width of the trajectory could be controlled by prescribing external field rotation. Successful verification experiments were performed on a prototype chip fabricated with excimer laser ablation in polycarbonate and electroforming of nickel flux-guides. Bead velocities up to 450 μm/s were measured in a 75 μm wide channel. By prescribing the currents in the external quadrupole magnet, the shape of the bead trajectory could be controlled.
NASA Technical Reports Server (NTRS)
2005-01-01
KENNEDY SPACE CENTER, FLA. In the Vehicle Assembly Building at NASAs Kennedy Space Center, workers mate the External Tank, at left, to the underside of Space Shuttle Discovery, at right. Each of two aft external tank umbilical plates mate with a corresponding plate on the orbiter. The plates help maintain alignment among the umbilicals. The attach fitting is aft of the nose gear wheel well. Workers next will perform an electrical and mechanical verification of the mated interfaces to verify all critical vehicle connections. A Shuttle interface test is performed using the launch processing system to verify Space Shuttle vehicle interfaces and Space Shuttle vehicle-to-ground interfaces. In approximately one week, Space Shuttle Discovery will be ready for rollout to Launch Pad 39B for Return to Flight mission STS-114. The launch window for STS-114 is May 15 to June 3.
NASA Technical Reports Server (NTRS)
Pasareanu, Corina S.; Giannakopoulou, Dimitra
2006-01-01
This paper discusses our initial experience with introducing automated assume-guarantee verification based on learning in the SPIN tool. We believe that compositional verification techniques such as assume-guarantee reasoning could complement the state-reduction techniques that SPIN already supports, thus increasing the size of systems that SPIN can handle. We present a "light-weight" approach to evaluating the benefits of learning-based assume-guarantee reasoning in the context of SPIN: we turn our previous implementation of learning for the LTSA tool into a main program that externally invokes SPIN to provide the model checking-related answers. Despite its performance overheads (which mandate a future implementation within SPIN itself), this approach provides accurate information about the savings in memory. We have experimented with several versions of learning-based assume guarantee reasoning, including a novel heuristic introduced here for generating component assumptions when their environment is unavailable. We illustrate the benefits of learning-based assume-guarantee reasoning in SPIN through the example of a resource arbiter for a spacecraft. Keywords: assume-guarantee reasoning, model checking, learning.
Program Model Checking as a New Trend
NASA Technical Reports Server (NTRS)
Havelund, Klaus; Visser, Willem; Clancy, Daniel (Technical Monitor)
2002-01-01
This paper introduces a special section of STTT (International Journal on Software Tools for Technology Transfer) containing a selection of papers that were presented at the 7th International SPIN workshop, Stanford, August 30 - September 1, 2000. The workshop was named SPIN Model Checking and Software Verification, with an emphasis on model checking of programs. The paper outlines the motivation for stressing software verification, rather than only design and model verification, by presenting the work done in the Automated Software Engineering group at NASA Ames Research Center within the last 5 years. This includes work in software model checking, testing like technologies and static analysis.
Computer Aided Dosimetry and Verification of Exposure to Radiation
2002-06-01
Event matrix 2. Hematopoietic * Absolute blood counts * Relative blood counts 3. Dosimetry * TLD * EPDQuantitative * Radiation survey * Whole body...EI1 Defence Research and Recherche et developpement Development Canada pour la d6fense Canada DEFENCE •mI•DEFENSE Computer Aided Dosimetry and...Aided Dosimetry and Verification of Exposure to Radiation Edward Waller SAIC Canada Robert Z Stodilka Radiation Effects Group, Space Systems and
Xu, Chuan; Huang, Xin-En; Wang, Shu-Xiang; Lv, Peng-Hua; Sun, Ling; Wang, Fu-An
2015-01-01
Percutaneous transhepatic biliary drainage (PTBD) is a form of palliative care for patients with malignant obstructive jaundice. We here compared the infection incidence between internal-external and external drainage for patients with malignant obstructive jaundice. Patients with malignant obstructive jaundice without infection before surgery receiving internal-external or external drainage from January 2008 to July 2014 were recruited. According to percutaneous transhepatic cholangiography (PTC), if the guide wire could pass through the occlusion and enter the duodenum, we recommended internal-external drainage, and external drainage biliary drainage was set up if the occlusion was not crossed. All patients with infection after procedure received a cultivation of blood and a bile bacteriological test. Among 110 patients with malignant obstructive jaundice, 22 (52.4%) were diagnosed with infection after the procedure in the internal-external drainage group, whereas 19 (27.9%) patients were so affected in the external drainage group, the difference being significant (p<0.05). In 8 patients (36.3%) in the internal-external group infection was controlled, as compared to 12 (63.1%) in the external group (p<0.05). The mortality rate for patients with infection not controlled in internal-external group in one month was 42.8%, while this rate in external group was 28.6% (p<0.05). External drainage is a good choice, which could significantly reduce the chance of biliary infection caused by bacteria, and decrease the mortality rate at one month and improve the long-term prognosis.
Age verification cards fail to fully prevent minors from accessing tobacco products.
Kanda, Hideyuki; Osaki, Yoneatsu; Ohida, Takashi; Kaneita, Yoshitaka; Munezawa, Takeshi
2011-03-01
Proper age verification can prevent minors from accessing tobacco products. For this reason, electronic locking devices based on a proof-of age system utilising cards were installed in almost every tobacco vending machine across Japan and Germany to restrict sales to minors. We aimed to clarify the associations between amount smoked by high school students and the usage of age verification cards by conducting a nationwide cross-sectional survey of students in Japan. This survey was conducted in 2008. We asked high school students, aged 13-18 years, in Japan about their smoking behaviour, where they purchase cigarettes, if or if not they have used age verification cards, and if yes, how they obtained this card. As the amount smoked increased, the prevalence of purchasing cigarettes from vending machines also rose for both males and females. The percentage of those with experience of using an age verification card was also higher among those who smoked more. Somebody outside of family was the top source of obtaining cards. Surprisingly, around 5% of males and females belonging to the group with highest smoking levels applied for cards themselves. Age verification cards cannot fully prevent minors from accessing tobacco products. These findings suggest that a total ban of tobacco vending machines, not an age verification system, is needed to prevent sales to minors.
Beltsios, Michail; Mavrogenis, Andreas F; Savvidou, Olga D; Karamanis, Eirineos; Kokkalis, Zinon T; Papagelopoulos, Panayiotis J
2014-07-01
To compare modular monolateral external fixators with single monolateral external fixators for the treatment of open and complex tibial shaft fractures, to determine the optimal construct for fracture union. A total of 223 tibial shaft fractures in 212 patients were treated with a monolateral external fixator from 2005 to 2011; 112 fractures were treated with a modular external fixator with ball-joints (group A), and 111 fractures were treated with a single external fixator without ball-joints (group B). The mean follow-up was 2.9 years. We retrospectively evaluated the operative time for fracture reduction with the external fixator, pain and range of motion of the knee and ankle joints, time to union, rate of malunion, reoperations and revisions of the external fixators, and complications. The time for fracture reduction was statistically higher in group B; the rate of union was statistically higher in group B; the rate of nonunion was statistically higher in group A; the mean time to union was statistically higher in group A; the rate of reoperations was statistically higher in group A; and the rate of revision of the external fixator was statistically higher in group A. Pain, range of motion of the knee and ankle joints, rates of delayed union, malunion and complications were similar. Although modular external fixators are associated with faster intraoperative fracture reduction with the external fixator, single external fixators are associated with significantly better rates of union and reoperations; the rates of delayed union, malunion and complications are similar.
Verification Challenges of Dynamic Testing of Space Flight Hardware
NASA Technical Reports Server (NTRS)
Winnitoy, Susan
2010-01-01
The Six Degree-of-Freedom Dynamic Test System (SDTS) is a test facility at the National Aeronautics and Space Administration (NASA) Johnson Space Center in Houston, Texas for performing dynamic verification of space structures and hardware. Some examples of past and current tests include the verification of on-orbit robotic inspection systems, space vehicle assembly procedures and docking/berthing systems. The facility is able to integrate a dynamic simulation of on-orbit spacecraft mating or demating using flight-like mechanical interface hardware. A force moment sensor is utilized for input to the simulation during the contact phase, thus simulating the contact dynamics. While the verification of flight hardware presents many unique challenges, one particular area of interest is with respect to the use of external measurement systems to ensure accurate feedback of dynamic contact. There are many commercial off-the-shelf (COTS) measurement systems available on the market, and the test facility measurement systems have evolved over time to include two separate COTS systems. The first system incorporates infra-red sensing cameras, while the second system employs a laser interferometer to determine position and orientation data. The specific technical challenges with the measurement systems in a large dynamic environment include changing thermal and humidity levels, operational area and measurement volume, dynamic tracking, and data synchronization. The facility is located in an expansive high-bay area that is occasionally exposed to outside temperature when large retractable doors at each end of the building are opened. The laser interferometer system, in particular, is vulnerable to the environmental changes in the building. The operational area of the test facility itself is sizeable, ranging from seven meters wide and five meters deep to as much as seven meters high. Both facility measurement systems have desirable measurement volumes and the accuracies vary within the respective volumes. In addition, because this is a dynamic facility with a moving test bed, direct line-of-sight may not be available at all times between the measurement sensors and the tracking targets. Finally, the feedback data from the active test bed along with the two external measurement systems must be synchronized to allow for data correlation. To ensure the desired accuracy and resolution of these systems, calibration of the systems must be performed regularly. New innovations in sensor technology itself are periodically incorporated into the facility s overall measurement scheme. In addressing the challenges of the measurement systems, the facility is able to provide essential position and orientation data to verify the dynamic performance of space flight hardware.
Analysis and test for space shuttle propellant dynamics
NASA Technical Reports Server (NTRS)
Berry, R. L.; Demchak, L. J.; Tegart, J. R.
1983-01-01
This report presents the results of a study to develop an analytical model capable of predicting the dynamic interaction forces on the Shuttle External Tank, due to large amplitude propellant slosh during RTLS separation. The report details low-g drop tower and KC-135 test programs that were conducted to investigate propellant reorientation during RTLS. In addition, the development of a nonlinear finite element slosh model (LAMPS2, two dimensional, and one LAMPS3, three dimensional) is presented. Correlation between the model and test data is presented as a verification of the modeling approach.
Galileo attitude and articulation control subsystem closed loop testing
NASA Technical Reports Server (NTRS)
Lembeck, M. F.; Pignatano, N. D.
1983-01-01
In order to ensure the reliable operation of the Attitude and Articulation Control Subsystem (AACS) which will guide the Galileo spacecraft on its two and one-half year journey to Jupiter, the AACS is being rigorously tested. The primary objectives of the test program are the verification of the AACS's form, fit, and function, especially with regard to subsystem external interfaces and the functional operation of the flight software. Attention is presently given to the Galileo Closed Loop Test System, which simulates the dynamic and 'visual' flight environment for AACS components in the laboratory.
Design and Verification of Critical Pressurised Windows for Manned Spaceflight
NASA Astrophysics Data System (ADS)
Lamoure, Richard; Busto, Lara; Novo, Francisco; Sinnema, Gerben; Leal, Mendes M.
2014-06-01
The Window Design for Manned Spaceflight (WDMS) project was tasked with establishing the state-of-art and explore possible improvements to the current structural integrity verification and fracture control methodologies for manned spacecraft windows.A critical review of the state-of-art in spacecraft window design, materials and verification practice was conducted. Shortcomings of the methodology in terms of analysis, inspection and testing were identified. Schemes for improving verification practices and reducing conservatism whilst maintaining the required safety levels were then proposed.An experimental materials characterisation programme was defined and carried out with the support of the 'Glass and Façade Technology Research Group', at the University of Cambridge. Results of the sample testing campaign were analysed, post-processed and subsequently applied to the design of a breadboard window demonstrator.Two Fused Silica glass window panes were procured and subjected to dedicated analyses, inspection and testing comprising both qualification and acceptance programmes specifically tailored to the objectives of the activity.Finally, main outcomes have been compiled into a Structural Verification Guide for Pressurised Windows in manned spacecraft, incorporating best practices and lessons learned throughout this project.
NASA Astrophysics Data System (ADS)
Torres-Xirau, I.; Olaciregui-Ruiz, I.; Rozendaal, R. A.; González, P.; Mijnheer, B. J.; Sonke, J.-J.; van der Heide, U. A.; Mans, A.
2017-08-01
In external beam radiotherapy, electronic portal imaging devices (EPIDs) are frequently used for pre-treatment and for in vivo dose verification. Currently, various MR-guided radiotherapy systems are being developed and clinically implemented. Independent dosimetric verification is highly desirable. For this purpose we adapted our EPID-based dose verification system for use with the MR-Linac combination developed by Elekta in cooperation with UMC Utrecht and Philips. In this study we extended our back-projection method to cope with the presence of an extra attenuating medium between the patient and the EPID. Experiments were performed at a conventional linac, using an aluminum mock-up of the MRI scanner housing between the phantom and the EPID. For a 10 cm square field, the attenuation by the mock-up was 72%, while 16% of the remaining EPID signal resulted from scattered radiation. 58 IMRT fields were delivered to a 20 cm slab phantom with and without the mock-up. EPID reconstructed dose distributions were compared to planned dose distributions using the γ -evaluation method (global, 3%, 3 mm). In our adapted back-projection algorithm the averaged {γmean} was 0.27+/- 0.06 , while in the conventional it was 0.28+/- 0.06 . Dose profiles of several square fields reconstructed with our adapted algorithm showed excellent agreement when compared to TPS.
Tang, Hsin-Yao; Beer, Lynn A.; Barnhart, Kurt T.; Speicher, David W.
2011-01-01
Stable isotope dilution-multiple reaction monitoring-mass spectrometry (SID-MRM-MS) has emerged as a promising platform for verification of serological candidate biomarkers. However, cost and time needed to synthesize and evaluate stable isotope peptides, optimize spike-in assays, and generate standard curves, quickly becomes unattractive when testing many candidate biomarkers. In this study, we demonstrate that label-free multiplexed MRM-MS coupled with major protein depletion and 1-D gel separation is a time-efficient, cost-effective initial biomarker verification strategy requiring less than 100 μl serum. Furthermore, SDS gel fractionation can resolve different molecular weight forms of targeted proteins with potential diagnostic value. Because fractionation is at the protein level, consistency of peptide quantitation profiles across fractions permits rapid detection of quantitation problems for specific peptides from a given protein. Despite the lack of internal standards, the entire workflow can be highly reproducible, and long-term reproducibility of relative protein abundance can be obtained using different mass spectrometers and LC methods with external reference standards. Quantitation down to ~200 pg/mL could be achieved using this workflow. Hence, the label-free GeLC-MRM workflow enables rapid, sensitive, and economical initial screening of large numbers of candidate biomarkers prior to setting up SID-MRM assays or immunoassays for the most promising candidate biomarkers. PMID:21726088
Tang, Hsin-Yao; Beer, Lynn A; Barnhart, Kurt T; Speicher, David W
2011-09-02
Stable isotope dilution-multiple reaction monitoring-mass spectrometry (SID-MRM-MS) has emerged as a promising platform for verification of serological candidate biomarkers. However, cost and time needed to synthesize and evaluate stable isotope peptides, optimize spike-in assays, and generate standard curves quickly becomes unattractive when testing many candidate biomarkers. In this study, we demonstrate that label-free multiplexed MRM-MS coupled with major protein depletion and 1D gel separation is a time-efficient, cost-effective initial biomarker verification strategy requiring less than 100 μL of serum. Furthermore, SDS gel fractionation can resolve different molecular weight forms of targeted proteins with potential diagnostic value. Because fractionation is at the protein level, consistency of peptide quantitation profiles across fractions permits rapid detection of quantitation problems for specific peptides from a given protein. Despite the lack of internal standards, the entire workflow can be highly reproducible, and long-term reproducibility of relative protein abundance can be obtained using different mass spectrometers and LC methods with external reference standards. Quantitation down to ~200 pg/mL could be achieved using this workflow. Hence, the label-free GeLC-MRM workflow enables rapid, sensitive, and economical initial screening of large numbers of candidate biomarkers prior to setting up SID-MRM assays or immunoassays for the most promising candidate biomarkers.
Engine Family Groups for Verification of Clean Diesel Technology
These documents show engine family boxes that represent groupings of engine families with similar characterists (i.e., the emissions standards that the engines were built to) for current and past model years.
Krevor, Brad; Capitman, John A; Oblak, Leslie; Cannon, Joanna B; Ruwe, Mathilda
2003-01-01
Efforts to prohibit the sales of tobacco and alcohol products to minors are widespread. Electronic Age Verification (EAV) devices are one possible means to improve compliance with sales to minors laws. The purpose of this study was to evaluate the implementation and effectiveness of EAV devices in terms of the frequency and accuracy of age verification, as well as to examine the impact of EAV's on the retailer environment. Two study locations were selected: Tallahassee, Florida and Iowa City, Iowa. Retail stores were invited to participate in the study, producing a self-selected experimental group. Stores that did not elect to test the EAV's comprised the comparison group. The data sources included: 1) mystery shopper inspections: two pre- and five post-EAV installation mystery shopper inspections of tobacco and alcohol retailers; 2) retail clerk and manager interviews; and 3) customer interviews. The study found that installing EAV devices with minimal training and encouragement did not increase age verification and underage sales refusal. Surveyed clerks reported positive experiences using the electronic ID readers and customers reported almost no discomfort about being asked to swipe their IDs. Observations from this study support the need for a more comprehensive system for responsible retailing.
Presnyakova, Darya; Archer, Will; Braun, David R; Flear, Wesley
2015-01-01
This study investigates morphological differences between flakes produced via "core and flake" technologies and those resulting from bifacial shaping strategies. We investigate systematic variation between two technological groups of flakes using experimentally produced assemblages, and then apply the experimental model to the Cutting 10 Mid -Pleistocene archaeological collection from Elandsfontein, South Africa. We argue that a specific set of independent variables--and their interactions--including external platform angle, platform depth, measures of thickness variance and flake curvature should distinguish between these two technological groups. The role of these variables in technological group separation was further investigated using the Generalized Linear Model as well as Linear Discriminant Analysis. The Discriminant model was used to classify archaeological flakes from the Cutting 10 locality in terms of their probability of association, within either experimentally developed technological group. The results indicate that the selected independent variables play a central role in separating core and flake from bifacial technologies. Thickness evenness and curvature had the greatest effect sizes in both the Generalized Linear and Discriminant models. Interestingly the interaction between thickness evenness and platform depth was significant and played an important role in influencing technological group membership. The identified interaction emphasizes the complexity in attempting to distinguish flake production strategies based on flake morphological attributes. The results of the discriminant function analysis demonstrate that the majority of flakes at the Cutting 10 locality were not associated with the production of the numerous Large Cutting Tools found at the site, which corresponds with previous suggestions regarding technological behaviors reflected in this assemblage.
Presnyakova, Darya; Archer, Will; Braun, David R.; Flear, Wesley
2015-01-01
This study investigates morphological differences between flakes produced via “core and flake” technologies and those resulting from bifacial shaping strategies. We investigate systematic variation between two technological groups of flakes using experimentally produced assemblages, and then apply the experimental model to the Cutting 10 Mid -Pleistocene archaeological collection from Elandsfontein, South Africa. We argue that a specific set of independent variables—and their interactions—including external platform angle, platform depth, measures of thickness variance and flake curvature should distinguish between these two technological groups. The role of these variables in technological group separation was further investigated using the Generalized Linear Model as well as Linear Discriminant Analysis. The Discriminant model was used to classify archaeological flakes from the Cutting 10 locality in terms of their probability of association, within either experimentally developed technological group. The results indicate that the selected independent variables play a central role in separating core and flake from bifacial technologies. Thickness evenness and curvature had the greatest effect sizes in both the Generalized Linear and Discriminant models. Interestingly the interaction between thickness evenness and platform depth was significant and played an important role in influencing technological group membership. The identified interaction emphasizes the complexity in attempting to distinguish flake production strategies based on flake morphological attributes. The results of the discriminant function analysis demonstrate that the majority of flakes at the Cutting 10 locality were not associated with the production of the numerous Large Cutting Tools found at the site, which corresponds with previous suggestions regarding technological behaviors reflected in this assemblage. PMID:26111251
Nguyen, Huynh; Morgan, David A F; Sly, Lindsay I; Benkovich, Morris; Cull, Sharon; Forwood, Mark R
2008-06-01
ISO 11137-2006 (ISO 11137-2a 2006) provides a VDmax 15 method for substantiation of 15 kGy as radiation sterilisation dose (RSD) for health care products with a relatively low sample requirement. Moreover, the method is also valid for products in which the bioburden level is less than or equal to 1.5. In the literature, the bioburden level of processed bone allografts is extremely low. Similarly, the Queensland Bone Bank (QBB) usually recovers no viable organisms from processed bone allografts. Because bone allografts are treated as a type of health care product, the aim of this research was to substantiate 15 kGy as a RSD for frozen bone allografts at the QBB using method VDmax 15-ISO 11137-2: 2006 (ISO 11137-2e, Procedure for method VDmax 15 for multiple production batches. Sterilisation of health care products - radiation - part 2: establishing the sterilisation dose, 2006; ISO 11137-2f, Procedure for method VDmax 15 for a single production batch. Sterilisation of health care products - radiation - part 2: establishing the sterilisation dose, 2006). 30 femoral heads, 40 milled bone allografts and 40 structural bone allografts manufactured according to QBB standard operating procedures were used. Estimated bioburdens for each bone allograft group were used to calculate the verification doses. Next, 10 samples per group were irradiated at the verification dose, sterility was tested and the number of positive tests of sterility recorded. If the number of positive samples was no more than 1, from the 10 tests carried out in each group, the verification was accepted and 15 kGy was substantiated as RSD for those bone allografts. The bioburdens in all three groups were 0, and therefore the verification doses were 0 kGy. Sterility tests of femoral heads and milled bones were all negative (no contamination), and there was one positive test of sterility in the structural bone allograft. Accordingly, the verification was accepted. Using the ISO validated protocol, VDmax 15, 15 kGy was substantiated as RSD for frozen bone allografts manufactured at the QBB.
Design of the software development and verification system (SWDVS) for shuttle NASA study task 35
NASA Technical Reports Server (NTRS)
Drane, L. W.; Mccoy, B. J.; Silver, L. W.
1973-01-01
An overview of the Software Development and Verification System (SWDVS) for the space shuttle is presented. The design considerations, goals, assumptions, and major features of the design are examined. A scenario that shows three persons involved in flight software development using the SWDVS in response to a program change request is developed. The SWDVS is described from the standpoint of different groups of people with different responsibilities in the shuttle program to show the functional requirements that influenced the SWDVS design. The software elements of the SWDVS that satisfy the requirements of the different groups are identified.
Teoh, Andrew B J; Goh, Alwyn; Ngo, David C L
2006-12-01
Biometric analysis for identity verification is becoming a widespread reality. Such implementations necessitate large-scale capture and storage of biometric data, which raises serious issues in terms of data privacy and (if such data is compromised) identity theft. These problems stem from the essential permanence of biometric data, which (unlike secret passwords or physical tokens) cannot be refreshed or reissued if compromised. Our previously presented biometric-hash framework prescribes the integration of external (password or token-derived) randomness with user-specific biometrics, resulting in bitstring outputs with security characteristics (i.e., noninvertibility) comparable to cryptographic ciphers or hashes. The resultant BioHashes are hence cancellable, i.e., straightforwardly revoked and reissued (via refreshed password or reissued token) if compromised. BioHashing furthermore enhances recognition effectiveness, which is explained in this paper as arising from the Random Multispace Quantization (RMQ) of biometric and external random inputs.
Cheng, Han-miao; Li, Hong-bin
2015-08-01
The existing electronic transformer calibration systems employing data acquisition cards cannot satisfy some practical applications, because the calibration systems have phase measurement errors when they work in the mode of receiving external synchronization signals. This paper proposes an improved calibration system scheme with phase correction to improve the phase measurement accuracy. We employ NI PCI-4474 to design a calibration system, and the system has the potential to receive external synchronization signals and reach extremely high accuracy classes. Accuracy verification has been carried out in the China Electric Power Research Institute, and results demonstrate that the system surpasses the accuracy class 0.05. Furthermore, this system has been used to test the harmonics measurement accuracy of all-fiber optical current transformers. In the same process, we have used an existing calibration system, and a comparison of the test results is presented. The system after improvement is suitable for the intended applications.
Correlation between the characteristics of resonance and aging of the external ear.
Silva, Aline Papin Roedas da; Blasca, Wanderléia Quinhoneiro; Lauris, José Roberto Pereira; Oliveira, Jerusa Roberta Massola de
2014-01-01
Aging causes changes in the external ear as a collapse of the external auditory canal and tympanic membrane senile. Knowing them is appropriate for the diagnosis of hearing loss and selection of hearing aids. For this reason, the study aimed to verify the influence of the anatomical changes of the external ear resonance in the auditory canal in the elderly. The sample consisted of objective measures of the external ear of elderly with collapse (group A), senile tympanic membrane (group B) and without changing the external auditory canal or tympanic membrane (group C) and adults without changing the external ear (group D). In the retrospective/clinical study were performed comparisons of measures of individuals with and without alteration of the external ear through the gain and response external ear resonant frequency and the primary peak to the right ear. In groups A, B and C was no statistically significant difference between Real Ear Unaided Response (REUR) and Real Ear Unaided Gain (REUG), but not for the peak frequency. For groups A and B were shown significant differences in REUR and REUG. Between the C and D groups were significant statistics to the REUR and REUG, but not for the frequency of the primary peak. Changes influence the external ear resonance, decreasing its amplitude. However, the frequency of the primary peak is not affected.
5HTTLPR genotype moderates the longitudinal impact of early caregiving on externalizing behavior
Smyke, Anna T.; Gleason, Mary Margaret; Nelson, Charles A.; Zeanah, Charles H.; Fox, Nathan A; Drury, Stacy S.
2014-01-01
We examined caregiver report of externalizing behavior from 12 to 54 months of age in 102 children randomized to care as usual in institutions or to newly-created high quality foster care. At baseline no differences by group or genotype in externalizing were found. However, changes in externalizing from baseline to 42 months of age were moderated by 5HTTLPR genotype and intervention group, where the slope for s/s individuals differed as a function of intervention group. The slope for individuals carrying the l allele did not significantly differ between groups. At 54 months of age, s/s children in the foster care group had the lowest levels of externalizing behavior, while children with the s/s genotype in the care as usual group demonstrated the highest rates of externalizing behavior. No intervention group differences were found in externalizing behavior among children who carried the l allele. These findings, within a randomized control trial of foster care compared to continued care as usual, indicate that 5HTTLPR genotype moderates the relation between early caregiving environments to predict externalizing behavior in children exposed to early institutional care in a manner most consistent with differential susceptibility. PMID:25640827
THE GLOBAL PERSPECTIVES AND HOW CAN THE ETV SCHEMES COOPERATE
Canada, the European Commission and US Environmental Technology Verification (ETV) programs have established an international group to develop a common approach to ETV. This group is also welcoming new members who have either a fully operating or pilot ETV program. The group ha...
6th Annual CMMI Technology Conference and User Group
2006-11-17
Operationally Oriented; Customer Focused Proven Approach – Level of Detail Beginner Decision Table (DT) is a tabular representation with tailoring options to...written to reflect the experience of the author Software Engineering led the process charge in the ’80s – Used Flowcharts – CASE tools – “data...Postpo ned PCR. Verification Steps • EPG configuration audits • EPG configuration status reports Flowcharts and Entry, Task, Verification and eXit
Prabhakar, Ramachandran
2012-01-01
Source to surface distance (SSD) plays a very important role in external beam radiotherapy treatment verification. In this study, a simple technique has been developed to verify the SSD automatically with lasers. The study also suggests a methodology for determining the respiratory signal with lasers. Two lasers, red and green are mounted on the collimator head of a Clinac 2300 C/D linac along with a camera to determine the SSD. A software (SSDLas) was developed to estimate the SSD automatically from the images captured by a 12-megapixel camera. To determine the SSD to a patient surface, the external body contour of the central axis transverse computed tomography (CT) cut is imported into the software. Another important aspect in radiotherapy is the generation of respiratory signal. The changes in the lasers separation as the patient breathes are converted to produce a respiratory signal. Multiple frames of laser images were acquired from the camera mounted on the collimator head and each frame was analyzed with SSDLas to generate the respiratory signal. The SSD as observed with the ODI on the machine and SSD measured by the SSDlas software was found to be within the tolerance limit. The methodology described for generating the respiratory signals will be useful for the treatment of mobile tumors such as lung, liver, breast, pancreas etc. The technique described for determining the SSD and the generation of respiratory signals using lasers is cost effective and simple to implement. Copyright © 2011 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
A Roadmap for the Implementation of Continued Process Verification.
Boyer, Marcus; Gampfer, Joerg; Zamamiri, Abdel; Payne, Robin
2016-01-01
In 2014, the members of the BioPhorum Operations Group (BPOG) produced a 100-page continued process verification case study, entitled "Continued Process Verification: An Industry Position Paper with Example Protocol". This case study captures the thought processes involved in creating a continued process verification plan for a new product in response to the U.S. Food and Drug Administration's guidance on the subject introduced in 2011. In so doing, it provided the specific example of a plan developed for a new molecular antibody product based on the "A MAb Case Study" that preceded it in 2009.This document provides a roadmap that draws on the content of the continued process verification case study to provide a step-by-step guide in a more accessible form, with reference to a process map of the product life cycle. It could be used as a basis for continued process verification implementation in a number of different scenarios: For a single product and process;For a single site;To assist in the sharing of data monitoring responsibilities among sites;To assist in establishing data monitoring agreements between a customer company and a contract manufacturing organization. The U.S. Food and Drug Administration issued guidance on the management of manufacturing processes designed to improve quality and control of drug products. This involved increased focus on regular monitoring of manufacturing processes, reporting of the results, and the taking of opportunities to improve. The guidance and practice associated with it is known as continued process verification This paper summarizes good practice in responding to continued process verification guidance, gathered from subject matter experts in the biopharmaceutical industry. © PDA, Inc. 2016.
Attributional biases about the origins of attitudes: externality, emotionality, and rationality.
Kenworthy, Jared B; Miller, Norman
2002-05-01
Pilot work and 3 studies investigated the ways people explain the origins of attitudes. Study I examined the use of 3 dimensions (externality, rationality, emotionality) to explain the origin of people's own, in-group, and out-group attitudes. Attributions for own attitudes were the least externally and emotionally based and the most rationally based. By comparison with the out-group, less externality, less emotionality, and more rationality also were attributed to in-group attitudes. Studies 2 and 3 examined the effects of intergroup threat on attributions for in- and out-group attitude positions. Under high threat, more externality and emotionality but less rationality were attributed to out-group attitudes than under low threat. Intergroup differentiation mediated the difference between out-group attributions under high and low threat.
Brett, Zoë H; Humphreys, Kathryn L; Smyke, Anna T; Gleason, Mary Margaret; Nelson, Charles A; Zeanah, Charles H; Fox, Nathan A; Drury, Stacy S
2015-02-01
We examined caregiver report of externalizing behavior from 12 to 54 months of age in 102 children randomized to care as usual in institutions or to newly created high-quality foster care. At baseline no differences by group or genotype in externalizing were found. However, changes in externalizing from baseline to 42 months of age were moderated by the serotonin transporter linked polymorphic region genotype and intervention group, where the slope for short-short (S/S) individuals differed as a function of intervention group. The slope for individuals carrying the long allele did not significantly differ between groups. At 54 months of age, S/S children in the foster care group had the lowest levels of externalizing behavior, while children with the S/S genotype in the care as usual group demonstrated the highest rates of externalizing behavior. No intervention group differences were found in externalizing behavior among children who carried the long allele. These findings, within a randomized controlled trial of foster care compared to continued care as usual, indicate that the serotonin transporter linked polymorphic region genotype moderates the relation between early caregiving environments to predict externalizing behavior in children exposed to early institutional care in a manner most consistent with differential susceptibility.
2010-09-01
what level of detail is needed to build their teams, and they can add more detailed items from the model in order to tap deeper in the performance of...of a project on ‘Command Team Effectiveness’ by Task Group 127 for the RTO Human Factors and Medicine Panel (RTG HFM-127). Published...vérification du modèle et de l’instrument) This Technical Report documents the findings of a project on ‘Command Team Effectiveness’ by Task Group
[Comparison of external fixation with or without limited internal fixation for open knee fractures].
Li, K N; Lan, H; He, Z Y; Wang, X J; Yuan, J; Zhao, P; Mu, J S
2018-03-01
Objective: To explore the characteristics and methods of different fixation methods and prevention of open knee joint fracture. Methods: The data of 86 cases of open knee joint fracture admitted from January 2002 to December 2015 in Department of Orthopaedics, Affiliated Hospital of Chengdu University were analyzed retrospectively.There were 65 males and 21 females aged of 38.6 years. There were 38 cases treated with trans articular external fixation alone, 48 cases were in the trans articular external fixation plus auxiliary limited internal fixation group. All the patients were treated according to the same three stages except for different fixation methods. Observation of external fixation and fracture fixation, fracture healing, wound healing and treatment, treatment and related factors of infection control and knee function recovery. χ(2) test was used to analyze data. Results: Eleven patients had primary wound healing, accounting for 12.8%. Seventy-five patients had two wounds healed, accounting for 87.2%. Only 38 cases of trans articular external fixator group had 31 cases of articular surface reduction, accounting for 81.6%; Five cases of trans articular external fixator assisted limited internal fixation group had 5 cases of poor reduction, accounting for 10.4%; There was significant difference between the two groups (χ(2)=44.132, P <0.05). Take a single cross joint external fixation group, a total of 23 cases of patients with infection, accounted for 60.5% of external fixation group; trans articular external fixation assisted limited internal fixation group there were 30 cases of patients with infection, accounting for the assistance of external fixator and limited internal fixation group 62.5%; There was significant difference between the two groups(χ(2)=0.035, P >0.05). Five cases of fracture nonunion cases of serious infection, patients voluntarily underwent amputation. The Lysholm Knee Scale: In the external fixation group, 23 cases were less than 50 points, accounting for 60.5%, 15 cases were more than 50 points, accounting for 39.5%, external fixation and limited internal fixation group 20 cases were less than 50 points, accounting for 41.7%, 28 cases were more than 50 points, accounting for 58.3%; There was significant difference between the two groups(χ(2)=1.279, P >0.05). Conclusions: Prevention and control of infection is a central link in the treatment of open fracture of the knee. Trans articular external fixator plus limited internal fixation is an important measure to treat open fracture of the knee-joint.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smartt, Heidi A.; Romero, Juan A.; Custer, Joyce Olsen
Containment/Surveillance (C/S) measures are critical to any verification regime in order to maintain Continuity of Knowledge (CoK). The Ceramic Seal project is research into the next generation technologies to advance C/S, in particular improving security and efficiency. The Ceramic Seal is a small form factor loop seal with improved tamper-indication including a frangible seal body, tamper planes, external coatings, and electronic monitoring of the seal body integrity. It improves efficiency through a self-securing wire and in-situ verification with a handheld reader. Sandia National Laboratories (SNL) and Savannah River National Laboratory (SRNL), under sponsorship from the U.S. National Nuclear Security Administrationmore » (NNSA) Office of Defense Nuclear Nonproliferation Research and Development (DNN R&D), have previously designed and have now fabricated and tested Ceramic Seals. Tests have occurred at both SNL and SRNL, with different types of tests occurring at each facility. This interim report will describe the Ceramic Seal prototype, the design and development of a handheld standalone reader and an interface to a data acquisition system, fabrication of the seals, and results of initial testing.« less
Kane, Greg
2013-11-04
A Drug Influence Evaluation (DIE) is a formal assessment of an impaired driving suspect, performed by a trained law enforcement officer who uses circumstantial facts, questioning, searching, and a physical exam to form an unstandardized opinion as to whether a suspect's driving was impaired by drugs. This paper first identifies the scientific studies commonly cited in American criminal trials as evidence of DIE accuracy, and second, uses the QUADAS tool to investigate whether the methodologies used by these studies allow them to correctly quantify the diagnostic accuracy of the DIEs currently administered by US law enforcement. Three studies were selected for analysis. For each study, the QUADAS tool identified biases that distorted reported accuracies. The studies were subject to spectrum bias, selection bias, misclassification bias, verification bias, differential verification bias, incorporation bias, and review bias. The studies quantified DIE performance with prevalence-dependent accuracy statistics that are internally but not externally valid. The accuracies reported by these studies do not quantify the accuracy of the DIE process now used by US law enforcement. These studies do not validate current DIE practice.
Poussin, Carine; Mathis, Carole; Alexopoulos, Leonidas G; Messinis, Dimitris E; Dulize, Rémi H J; Belcastro, Vincenzo; Melas, Ioannis N; Sakellaropoulos, Theodore; Rhrissorrakrai, Kahn; Bilal, Erhan; Meyer, Pablo; Talikka, Marja; Boué, Stéphanie; Norel, Raquel; Rice, John J; Stolovitzky, Gustavo; Ivanov, Nikolai V; Peitsch, Manuel C; Hoeng, Julia
2014-01-01
The biological responses to external cues such as drugs, chemicals, viruses and hormones, is an essential question in biomedicine and in the field of toxicology, and cannot be easily studied in humans. Thus, biomedical research has continuously relied on animal models for studying the impact of these compounds and attempted to ‘translate’ the results to humans. In this context, the SBV IMPROVER (Systems Biology Verification for Industrial Methodology for PROcess VErification in Research) collaborative initiative, which uses crowd-sourcing techniques to address fundamental questions in systems biology, invited scientists to deploy their own computational methodologies to make predictions on species translatability. A multi-layer systems biology dataset was generated that was comprised of phosphoproteomics, transcriptomics and cytokine data derived from normal human (NHBE) and rat (NRBE) bronchial epithelial cells exposed in parallel to more than 50 different stimuli under identical conditions. The present manuscript describes in detail the experimental settings, generation, processing and quality control analysis of the multi-layer omics dataset accessible in public repositories for further intra- and inter-species translation studies. PMID:25977767
Poussin, Carine; Mathis, Carole; Alexopoulos, Leonidas G; Messinis, Dimitris E; Dulize, Rémi H J; Belcastro, Vincenzo; Melas, Ioannis N; Sakellaropoulos, Theodore; Rhrissorrakrai, Kahn; Bilal, Erhan; Meyer, Pablo; Talikka, Marja; Boué, Stéphanie; Norel, Raquel; Rice, John J; Stolovitzky, Gustavo; Ivanov, Nikolai V; Peitsch, Manuel C; Hoeng, Julia
2014-01-01
The biological responses to external cues such as drugs, chemicals, viruses and hormones, is an essential question in biomedicine and in the field of toxicology, and cannot be easily studied in humans. Thus, biomedical research has continuously relied on animal models for studying the impact of these compounds and attempted to 'translate' the results to humans. In this context, the SBV IMPROVER (Systems Biology Verification for Industrial Methodology for PROcess VErification in Research) collaborative initiative, which uses crowd-sourcing techniques to address fundamental questions in systems biology, invited scientists to deploy their own computational methodologies to make predictions on species translatability. A multi-layer systems biology dataset was generated that was comprised of phosphoproteomics, transcriptomics and cytokine data derived from normal human (NHBE) and rat (NRBE) bronchial epithelial cells exposed in parallel to more than 50 different stimuli under identical conditions. The present manuscript describes in detail the experimental settings, generation, processing and quality control analysis of the multi-layer omics dataset accessible in public repositories for further intra- and inter-species translation studies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miften, M.
2016-06-15
AAPM TG-135U1 QA for Robotic Radiosurgery - Sonja Dieterich Since the publication of AAPM TG-135 in 2011, the technology of robotic radiosurgery has rapidly developed. AAPM TG-135U1 will provide recommendations on the clinical practice for using the IRIS collimator, fiducial-less real-time motion tracking, and Monte Carlo based treatment planning. In addition, it will summarize currently available literature about uncertainties. Learning Objectives: Understand the progression of technology since the first TG publication Learn which new QA procedures should be implemented for new technologies Be familiar with updates to clinical practice guidelines AAPM TG-178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance -more » Steven Goetsch Purpose: AAPM Task Group 178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance was formed in August, 2008. The Task Group has 12 medical physicists, two physicians and two consultants. Methods: A round robin dosimetry intercomparison of proposed ionization chambers, electrometer and dosimetry phantoms was conducted over a 15 month period in 2011 and 2012 (Med Phys 42, 11, Nov, 2015). The data obtained at 9 institutions (with ten different Elekta Gamma Knife units) was analyzed by the lead author using several protocols. Results: The most consistent results were obtained using the Elekta ABS 16cm diameter phantom, with the TG-51 protocol modified as recommended by Alfonso et al (Med Phys 35, 11, Nov 2008). A key white paper (Med Phys, in press) sponsored by Elekta Corporation, was used to obtain correction factors for the ionization chambers and phantoms used in this intercomparison. Consistent results were obtained for both Elekta Gamma Knife Model 4C and Gamma Knife Perfexion units as measured with each of two miniature ionization chambers. Conclusion: The full report gives clinical history and background of gamma stereotactic radiosurgery, clinical examples and history, quality assurance recommendations and outline of possible dosimetry protocols. The report will be reviewed by the AAPM Working Group on Recommendations for Radiotherapy External Beam Quality Assurance and then by the AAPM Science Council before publication in Medical Physics Survey of possible calibration protocols for calibration of Gamma Stereotactic Radiosurgery (GSR) devices Overview of modern Quality Assurance techniques for GSR AAPM TG-218 Tolerance Levels and Methodologies for IMRT Verification QA - Moyed Miften Patient-specific IMRT QA measurement is a process designed to identify discrepancies between calculated and delivered doses. Error tolerance limits are not well-defined or consistently applied across centers. The AAPM TG-218 report has been prepared to improve the understanding and consistency of this process by providing recommendations for methodologies and tolerance limits in patient-specific IMRT QA. Learning Objectives: Review measurement methods and methodologies for absolute dose verification Provide recommendations on delivery methods, data interpretation, the use of analysis routines and choice of tolerance limits for IMRT QA Sonja Dieterich has a research agreement with Sun Nuclear Inc. Steven Goetsch is a part-time consultant for Elekta.« less
Magnetically controlled ferromagnetic swimmers
Hamilton, Joshua K.; Petrov, Peter G.; Winlove, C. Peter; Gilbert, Andrew D.; Bryan, Matthew T.; Ogrin, Feodor Y.
2017-01-01
Microscopic swimming devices hold promise for radically new applications in lab-on-a-chip and microfluidic technology, diagnostics and drug delivery etc. In this paper, we demonstrate the experimental verification of a new class of autonomous ferromagnetic swimming devices, actuated and controlled solely by an oscillating magnetic field. These devices are based on a pair of interacting ferromagnetic particles of different size and different anisotropic properties joined by an elastic link and actuated by an external time-dependent magnetic field. The net motion is generated through a combination of dipolar interparticle gradient forces, time-dependent torque and hydrodynamic coupling. We investigate the dynamic performance of a prototype (3.6 mm) of the ferromagnetic swimmer in fluids of different viscosity as a function of the external field parameters (frequency and amplitude) and demonstrate stable propulsion over a wide range of Reynolds numbers. We show that the direction of swimming has a dependence on both the frequency and amplitude of the applied external magnetic field, resulting in robust control over the speed and direction of propulsion. This paves the way to fabricating microscale devices for a variety of technological applications requiring reliable actuation and high degree of control. PMID:28276490
Magnetically controlled ferromagnetic swimmers
NASA Astrophysics Data System (ADS)
Hamilton, Joshua K.; Petrov, Peter G.; Winlove, C. Peter; Gilbert, Andrew D.; Bryan, Matthew T.; Ogrin, Feodor Y.
2017-03-01
Microscopic swimming devices hold promise for radically new applications in lab-on-a-chip and microfluidic technology, diagnostics and drug delivery etc. In this paper, we demonstrate the experimental verification of a new class of autonomous ferromagnetic swimming devices, actuated and controlled solely by an oscillating magnetic field. These devices are based on a pair of interacting ferromagnetic particles of different size and different anisotropic properties joined by an elastic link and actuated by an external time-dependent magnetic field. The net motion is generated through a combination of dipolar interparticle gradient forces, time-dependent torque and hydrodynamic coupling. We investigate the dynamic performance of a prototype (3.6 mm) of the ferromagnetic swimmer in fluids of different viscosity as a function of the external field parameters (frequency and amplitude) and demonstrate stable propulsion over a wide range of Reynolds numbers. We show that the direction of swimming has a dependence on both the frequency and amplitude of the applied external magnetic field, resulting in robust control over the speed and direction of propulsion. This paves the way to fabricating microscale devices for a variety of technological applications requiring reliable actuation and high degree of control.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wendt, Fabian F; Yu, Yi-Hsiang; Nielsen, Kim
This is the first joint reference paper for the Ocean Energy Systems (OES) Task 10 Wave Energy Converter modeling verification and validation group. The group is established under the OES Energy Technology Network program under the International Energy Agency. OES was founded in 2001 and Task 10 was proposed by Bob Thresher (National Renewable Energy Laboratory) in 2015 and approved by the OES Executive Committee EXCO in 2016. The kickoff workshop took place in September 2016, wherein the initial baseline task was defined. Experience from similar offshore wind validation/verification projects (OC3-OC5 conducted within the International Energy Agency Wind Task 30)more » [1], [2] showed that a simple test case would help the initial cooperation to present results in a comparable way. A heaving sphere was chosen as the first test case. The team of project participants simulated different numerical experiments, such as heave decay tests and regular and irregular wave cases. The simulation results are presented and discussed in this paper.« less
The Impact of Parents, Child Care Providers, Teachers, and Peers on Early Externalizing Trajectories
Silver, Rebecca B.; Measelle, Jeffrey R.; Armstrong, Jeffrey M.; Essex, Marilyn J.
2010-01-01
This study utilized growth mixture modeling to examine the impact of parents, child care providers, teachers, and peers on the prediction of distinct developmental patterns of classroom externalizing behavior in elementary school. Among 241 children, three groups were identified. 84.6% of children exhibited consistently low externalizing behavior. The externalizing behavior of the Chronic High group (5.8%) remained elevated throughout elementary school; it increased over time in the Low Increasing group (9.5%). Negative relationships with teachers and peers in the kindergarten classroom increased the odds of having chronically high externalizing behavior. Teacher–child conflict increased the likelihood of a developmental pattern of escalating externalizing behavior. Boys were overrepresented in the behaviorally risky groups, and no sex differences in trajectory types were found. PMID:21094398
A process improvement model for software verification and validation
NASA Technical Reports Server (NTRS)
Callahan, John; Sabolish, George
1994-01-01
We describe ongoing work at the NASA Independent Verification and Validation (IV&V) Facility to establish a process improvement model for software verification and validation (V&V) organizations. This model, similar to those used by some software development organizations, uses measurement-based techniques to identify problem areas and introduce incremental improvements. We seek to replicate this model for organizations involved in V&V on large-scale software development projects such as EOS and space station. At the IV&V Facility, a university research group and V&V contractors are working together to collect metrics across projects in order to determine the effectiveness of V&V and improve its application. Since V&V processes are intimately tied to development processes, this paper also examines the repercussions for development organizations in large-scale efforts.
A process improvement model for software verification and validation
NASA Technical Reports Server (NTRS)
Callahan, John; Sabolish, George
1994-01-01
We describe ongoing work at the NASA Independent Verification and Validation (IV&V) Facility to establish a process improvement model for software verification and validation (V&V) organizations. This model, similar to those used by some software development organizations, uses measurement-based techniques to identify problem areas and introduce incremental improvements. We seek to replicate this model for organizations involved in V&V on large-scale software development projects such as EOS and Space Station. At the IV&V Facility, a university research group and V&V contractors are working together to collect metrics across projects in order to determine the effectiveness of V&V and improve its application. Since V&V processes are intimately tied to development processes, this paper also examines the repercussions for development organizations in large-scale efforts.
Liu, Wenlong; Zhang, Xili; He, Fuyuan; Zhang, Ping; Wang, Haiqin; Wu, Dezhi; Chen, Zuohong
2011-11-01
To establish and experimental verification the mathematical model of the balance groups that is the steady-state of traditional Chinese medicine in extraction. Using the entropy and genetic principles of statistics, and taking the coefficient of variation of GC fingerprint which is the naphtha of the Houttuynia cordata between strains in the same GAP place as a pivot to establish and verify the mathematical model was established of the balance groups that is the steady-state of traditional Chinese medicine in extraction. A mathematical model that is suitable for the balance groups of the steady-state of traditional Chinese medicine and preparation in extraction, and the balance groups which is 29 683 strains (approximately 118.7 kg) were gained with the same origin of H. cordata as the model drug. Under the GAP of quality control model, controlling the stability of the quality through further using the Hardy-Weinberg balance groups of the H. cordata between strains, the new theory and experiment foundation is established for the steady-state of traditional Chinese medicine in extraction and quality control.
Z-2 Architecture Description and Requirements Verification Results
NASA Technical Reports Server (NTRS)
Graziosi, Dave; Jones, Bobby; Ferl, Jinny; Scarborough, Steve; Hewes, Linda; Ross, Amy; Rhodes, Richard
2016-01-01
The Z-2 Prototype Planetary Extravehicular Space Suit Assembly is a continuation of NASA's Z series of spacesuits. The Z-2 is another step in NASA's technology development roadmap leading to human exploration of the Martian surface. The suit was designed for maximum mobility at 8.3 psid, reduced mass, and to have high fidelity life support interfaces. As Z-2 will be man-tested at full vacuum in NASA JSC's Chamber B, it was manufactured as Class II, making it the most flight-like planetary walking suit produced to date. The Z-2 suit architecture is an evolution of previous EVA suits, namely the ISS EMU, Mark III, Rear Entry I-Suit and Z-1 spacesuits. The suit is a hybrid hard and soft multi-bearing, rear entry spacesuit. The hard upper torso (HUT) is an all-composite structure and includes a 2-bearing rolling convolute shoulder with Vernier sizing mechanism, removable suit port interface plate (SIP), elliptical hemispherical helmet and self-don/doff shoulder harness. The hatch is a hybrid aluminum and composite construction with Apollo style gas connectors, custom water pass-thru, removable hatch cage and interfaces to primary and auxiliary life support feed water bags. The suit includes Z-1 style lower arms with cam brackets for Vernier sizing and government furnished equipment (GFE) Phase VI gloves. The lower torso includes a telescopic waist sizing system, waist bearing, rolling convolute waist joint, hard brief, 2 bearing soft hip thigh, Z-1 style legs with ISS EMU style cam brackets for sizing, and conformal walking boots with ankle bearings. The Z-2 Requirements Verification Plan includes the verification of more than 200 individual requirements. The verification methods include test, analysis, inspection, demonstration or a combination of methods. Examples of unmanned requirements include suit leakage, proof pressure testing, operational life, mass, isometric man-loads, sizing adjustment ranges, internal and external interfaces such as in-suit drink bag, partial pressure relief valve, purge valve, donning stand and ISS Body Restraint Tether (BRT). Examples of manned requirements include verification of anthropometric range, suit self-don/doff, secondary suit exit method, donning stand self-ingress/egress and manned mobility covering eight functional tasks. The eight functional tasks include kneeling with object pick-up, standing toe touch, cross-body reach, walking, reach to the SIP and helmet visor. This paper will provide an overview of the Z-2 design. Z-2 requirements verification testing was performed with NASA at the ILC Houston test facility. This paper will also discuss pre-delivery manned and unmanned test results as well as analysis performed in support of requirements verification.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Udrescu, Corina; Mornex, Francoise, E-mail: francoise.mornex@chu-lyon.fr; Tanguy, Ronan
2013-01-01
Purpose: The intrafraction verification provided by ExacTrac X-ray 6D Snap Verification (ET-SV) allows the tracking of potential isocenter displacements throughout patient position and treatment. The aims of this study were (1) to measure the intrafraction variations of the isocenter position (random errors); (2) to study the amplitude of the variation related to the fraction duration; and (3) to assess the impact of the table movement on positioning uncertainties. Methods and Materials: ET-SV uses images acquired before or during treatment delivery or both to detect isocenter displacement. Twenty patients treated with stereotactic body radiation therapy (SBRT) for lung tumors underwent SVmore » before or during each beam. Noncoplanar beams were sometimes necessary. The time between the setup of the patient and each SV was noted, and values of deviations were compiled for 3 SV time groups: SV performed at {<=}10 min (group 1), between 11 and 20 min (group 2), and {>=}21 min (group 3). Random errors in positioning during the use of noncoplanar fields were noted. Results: The mean isocenter deviation {+-}SD was 2 {+-} 0.5 mm (range, 1-8 mm). The average deviations {+-}SD increased significantly from 1.6 {+-} 0.5 mm to 2.1 {+-} 0.8 mm and 2.2 {+-} 0.6 mm for groups 1, 2, and 3 (P=.002), respectively. Percentages of deviation {>=}3 mm were 7.06%, 22.83%, and 28.07% and 1.08%, 4.15%, and 8.4% for {>=}5 mm (P<.0001). For 11 patients, table rotation was necessary. The mean isocenter deviation {+-}SD increased significantly from 1.9 {+-} 0.5 mm before table rotation to 2.7 {+-} 0.5 mm (P=.001) for the first beam treated after rotation. Conclusions: SV detects isocenter deviations, which increase in amplitude and frequency with the fraction duration, and enables intrafraction verification for SBRT (taking into account clinical condition and technical issues). SV gives accurate targeting at any time during irradiation and may raise confidence to escalate the dose. SV appears to be an important tool for ensuring the quality control of SBRT.« less
NASA Astrophysics Data System (ADS)
Kim, Cheol-kyun; Kim, Jungchan; Choi, Jaeseung; Yang, Hyunjo; Yim, Donggyu; Kim, Jinwoong
2007-03-01
As the minimum transistor length is getting smaller, the variation and uniformity of transistor length seriously effect device performance. So, the importance of optical proximity effects correction (OPC) and resolution enhancement technology (RET) cannot be overemphasized. However, OPC process is regarded by some as a necessary evil in device performance. In fact, every group which includes process and design, are interested in whole chip CD variation trend and CD uniformity, which represent real wafer. Recently, design based metrology systems are capable of detecting difference between data base to wafer SEM image. Design based metrology systems are able to extract information of whole chip CD variation. According to the results, OPC abnormality was identified and design feedback items are also disclosed. The other approaches are accomplished on EDA companies, like model based OPC verifications. Model based verification will be done for full chip area by using well-calibrated model. The object of model based verification is the prediction of potential weak point on wafer and fast feed back to OPC and design before reticle fabrication. In order to achieve robust design and sufficient device margin, appropriate combination between design based metrology system and model based verification tools is very important. Therefore, we evaluated design based metrology system and matched model based verification system for optimum combination between two systems. In our study, huge amount of data from wafer results are classified and analyzed by statistical method and classified by OPC feedback and design feedback items. Additionally, novel DFM flow would be proposed by using combination of design based metrology and model based verification tools.
Mock, U; Dieckmann, K; Wolff, U; Knocke, T H; Pötter, R
1999-08-01
Geometrical accuracy in patient positioning can vary substantially during external radiotherapy. This study estimated the set-up accuracy during pelvic irradiation for gynecological malignancies for determination of safety margins (planning target volume, PTV). Based on electronic portal imaging devices (EPID), 25 patients undergoing 4-field pelvic irradiation for gynecological malignancies were analyzed with regard to set-up accuracy during the treatment course. Regularly performed EPID images were used in order to systematically assess the systematic and random component of set-up displacements. Anatomical matching of verification and simulation images was followed by measuring corresponding distances between the central axis and anatomical features. Data analysis of set-up errors referred to the x-, y-,and z-axes. Additionally, cumulative frequencies were evaluated. A total of 50 simulation films and 313 verification images were analyzed. For the anterior-posterior (AP) beam direction mean deviations along the x- and z-axes were 1.5 mm and -1.9 mm, respectively. Moreover, random errors of 4.8 mm (x-axis) and 3.0 mm (z-axis) were determined. Concerning the latero-lateral treatment fields, the systematic errors along the two axes were calculated to 2.9 mm (y-axis) and -2.0 mm (z-axis) and random errors of 3.8 mm and 3.5 mm were found, respectively. The cumulative frequency of misalignments < or =5 mm showed values of 75% (AP fields) and 72% (latero-lateral fields). With regard to cumulative frequencies < or =10 mm quantification revealed values of 97% for both beam directions. During external pelvic irradiation therapy for gynecological malignancies, EPID images on a regular basis revealed acceptable set-up inaccuracies. Safety margins (PTV) of 1 cm appear to be sufficient, accounting for more than 95% of all deviations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Samuel, D; Testa, M; Park, Y
Purpose: In-vivo dose and beam range verification in proton therapy could play significant roles in proton treatment validation and improvements. Invivo beam range verification, in particular, could enable new treatment techniques one of which, for example, could be the use of anterior fields for prostate treatment instead of opposed lateral fields as in current practice. We have developed and commissioned an integrated system with hardware, software and workflow protocols, to provide a complete solution, simultaneously for both in-vivo dosimetry and range verification for proton therapy. Methods: The system uses a matrix of diodes, up to 12 in total, but separablemore » into three groups for flexibility in application. A special amplifier was developed to capture extremely small signals from very low proton beam current. The software was developed within iMagX, a general platform for image processing in radiation therapy applications. The range determination exploits the inherent relationship between the internal range modulation clock of the proton therapy system and the radiological depth at the point of measurement. The commissioning of the system, for in-vivo dosimetry and for range verification was separately conducted using anthropomorphic phantom. EBT films and TLDs were used for dose comparisons and range scan of the beam distal fall-off was used as ground truth for range verification. Results: For in-vivo dose measurement, the results were in agreement with TLD and EBT films and were within 3% from treatment planning calculations. For range verification, a precision of 0.5mm is achieved in homogeneous phantoms, and a precision of 2mm for anthropomorphic pelvic phantom, except at points with significant range mixing. Conclusion: We completed the commissioning of our system for in-vivo dosimetry and range verification in proton therapy. The results suggest that the system is ready for clinical trials on patient.« less
Personal Identification by Keystroke Dynamics in Japanese Free Text Typing
NASA Astrophysics Data System (ADS)
Samura, Toshiharu; Nishimura, Haruhiko
Biometrics is classified into verification and identification. Many researchers on the keystroke dynamics have treated the verification of a fixed short password which is used for the user login. In this research, we pay attention to the identification and investigate several characteristics of the keystroke dynamics in Japanese free text typing. We developed Web-based typing software in order to collect the keystroke data on the Local Area Network and performed experiments on a total of 112 subjects, from which three groups of typing level, the beginner's level and above, the normal level and above and the middle level and above were constructed. Based on the identification methods by the weighted Euclid distance and the neural network for the extracted feature indexes in Japanese texts, we evaluated identification performances for the three groups. As a result, high accuracy of personal identification was confirmed in both methods, in proportion to the typing level of the group.
An Integrated Environment for Efficient Formal Design and Verification
NASA Technical Reports Server (NTRS)
1998-01-01
The general goal of this project was to improve the practicality of formal methods by combining techniques from model checking and theorem proving. At the time the project was proposed, the model checking and theorem proving communities were applying different tools to similar problems, but there was not much cross-fertilization. This project involved a group from SRI that had substantial experience in the development and application of theorem-proving technology, and a group at Stanford that specialized in model checking techniques. Now, over five years after the proposal was submitted, there are many research groups working on combining theorem-proving and model checking techniques, and much more communication between the model checking and theorem proving research communities. This project contributed significantly to this research trend. The research work under this project covered a variety of topics: new theory and algorithms; prototype tools; verification methodology; and applications to problems in particular domains.
Zhu, X R; Jursinic, P A; Grimm, D F; Lopez, F; Rownd, J J; Gillin, M T
2002-08-01
A new type of radiographic film, Kodak EDR2 film, was evaluated for dose verification of intensity modulated radiation therapy (IMRT) delivered by a static multileaf collimator (SMLC). A sensitometric curve of EDR2 film irradiated by a 6 MV x-ray beam was compared with that of Kodak X-OMAT V (XV) film. The effects of field size, depth and dose rate on the sensitometric curve were also studied. It is found that EDR2 film is much less sensitive than XV film. In high-energy x-ray beams, the double hit process is the dominant mechanism that renders the grains on EDR2 films developable. As a result, in the dose range that is commonly used for film dosimetry for IMRT and conventional external beam therapy, the sensitometric curves of EDR2 films cannot be approximated as a linear function, OD = c * D. Within experimental uncertainty, the film sensitivity does not depend on the dose rate (50 vs 300 MU/min) or dose per pulse (from 1.0 x 10(-4) to 4.21 x 10(-4) Gy/pulse). Field sizes and depths (up to field size of 10 x 10 cm2 and depth = 10 cm) have little effect on the sensitometric curves. Percent depth doses (PDDs) for both 6 and 23 MV x rays were measured with both EDR2 and XV films and compared with ion chamber data. Film data are within 2.5% of the ion chamber results. Dose profiles measured with EDR2 film are consistent with those measured with an ion chamber. Examples of measured IMRT isodose distributions versus calculated isodoses are presented. We have used EDR2 films for verification of all IMRT patients treated by SMLC in our clinic. In most cases, with EDR2 film, actual clinical daily fraction doses can be used for verification of composite isodose distributions of SMLC-based IMRT.
Kopylov, Philippe; Geijer, Mats; Tägil, Magnus
2009-01-01
Background and purpose In unstable distal radial fractures that are impossible to reduce or to maintain in reduced position, the treatment of choice is operation. The type of operation and the choice of implant, however, is a matter of discussion. Our aim was to investigate whether open reduction and internal fixation would produce a better result than traditional external fixation. Methods 50 patients with an unstable or comminute distal radius fracture were randomized to either closed reduction and bridging external fixation, or open reduction and internal fixation using the TriMed system. The primary outcome parameter was grip strength, but the patients were followed for 1 year with objective clinical assessment, subjective outcome using DASH, and radiographic examination. Results At 1 year postoperatively, grip strength was 90% (SD 16) of the uninjured side in the internal fixation group and 78% (17) in the external fixation group. Pronation/supination was 150° (15) in the internal fixation group and 136° (20) in the external fixation group at 1 year. There were no differences in DASH scores or in radiographic parameters. 5 patients in the external fixation group were reoperated due to malunion, as compared to 1 in the internal fixation group. 7 other cases were classified as radiographic malunion: 5 in the external fixation group and 2 in the internal fixation group. Interpretation Internal fixation gave better grip strength and a better range of motion at 1 year, and tended to have less malunions than external fixation. No difference could be found regarding subjective outcome. PMID:19857180
Shuttle to space station transfer of the materials exposure facility
NASA Technical Reports Server (NTRS)
Shannon, David T., Jr.; Klich, Phillip J.
1995-01-01
The Materials Exposure Facility (MEF) is being proposed by LaRC as the first long-term space materials exposure facility with real-time interaction with materials experiments in actual conditions of orbital space flight. The MEF is proposed as a Space Station external payload dedicated to technology advancement in spacecraft materials and coatings research. This paper will define a set of potential logistics for removing the MEF from the Shuttle cargo bay and the process required for transferring the MEF to a specific external payload site on Space Station Freedom (SSF). The SSF UF-2 configuration is used for this study. The kinematics and ability to successfully perform the appropriate MEF maneuvers required were verified. During completion of this work, the Space Station was redesigned and the International Space Station Alpha (ISSA) configuration evolved. The transfer procedure for SSF was valid for ISSA; however, a verification of kinematics and clearances was essential. Also, SSF and ISSA robotic interfaces with the Orbiter were different.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cheng, Han-miao, E-mail: chenghanmiao@hust.edu.cn; Li, Hong-bin, E-mail: lihongbin@hust.edu.cn; State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Wuhan 430074
The existing electronic transformer calibration systems employing data acquisition cards cannot satisfy some practical applications, because the calibration systems have phase measurement errors when they work in the mode of receiving external synchronization signals. This paper proposes an improved calibration system scheme with phase correction to improve the phase measurement accuracy. We employ NI PCI-4474 to design a calibration system, and the system has the potential to receive external synchronization signals and reach extremely high accuracy classes. Accuracy verification has been carried out in the China Electric Power Research Institute, and results demonstrate that the system surpasses the accuracy classmore » 0.05. Furthermore, this system has been used to test the harmonics measurement accuracy of all-fiber optical current transformers. In the same process, we have used an existing calibration system, and a comparison of the test results is presented. The system after improvement is suitable for the intended applications.« less
In-Flight Characterization of the Electromagnetic Environment Inside an Airliner
NASA Technical Reports Server (NTRS)
Moeller, Karl J.; Dudley, Kenneth L.; Quach, Cuong C.; Koppen, Sandra V.
2001-01-01
In 1995, the NASA Langley Research Center conducted a series of experimental measurements that characterized the electromagnetic environment (EME) inside a Boeing 757 airliner while in flight, Measurements were made of the electromagnetic energy coupled into a commercially configured aircraft as it was flown in close proximity to ground-based radio frequency (RF) transmitters operating at approximately 26, 173. and 430 MHz. The goal of this experiment was to collect data for the verification of analytical predictions of the internal aircraft response to an external stimulus. This paper describes the experiment, presents the data collected by it, and discusses techniques used to compute both the magnitude of the electric field illuminating the aircraft and its direction of propagation relative to a coordinate system fixed to the aircraft. The latter is determined from Global Positioning System (GPS) and aircraft Inertial Reference Unit (IRU) data. The paper concludes with an examination of the shielding effectiveness of the test aircraft. as determined by comparison of' the measured internal EME and computed external EME.
A Randomized Clinical Trial Evaluating rh-FGF-2/β-TCP in Periodontal Defects.
Cochran, D L; Oh, T-J; Mills, M P; Clem, D S; McClain, P K; Schallhorn, R A; McGuire, M K; Scheyer, E T; Giannobile, W V; Reddy, M S; Abou-Arraj, R V; Vassilopoulos, P J; Genco, R J; Geurs, N C; Takemura, A
2016-05-01
Biological mediators have been used to enhance periodontal regeneration. The aim of this prospective randomized controlled study was to evaluate the safety and effectiveness of 3 doses of fibroblast growth factor 2 (FGF-2) when combined with a β-tricalcium phosphate (β-TCP) scaffold carrier placed in vertical infrabony periodontal defects in adult patients. In this double-blinded, dose-verification, externally monitored clinical study, 88 patients who required surgical intervention to treat a qualifying infrabony periodontal defect were randomized to 1 of 4 treatment groups-β-TCP alone (control) and 0.1% recombinant human FGF-2 (rh-FGF-2), 0.3% rh-FGF-2, and 0.4% rh-FGF-2 with β-TCP-following scaling and root planing of the tooth prior to a surgical appointment. Flap surgery was performed with EDTA conditioning of the root prior to device implantation. There were no statistically significant differences in patient demographics and baseline characteristics among the 4 treatment groups. When a composite outcome of gain in clinical attachment of 1.5 mm was used with a linear bone growth of 2.5 mm, a dose response pattern detected a plateau in the 0.3% and 0.4% rh-FGF-2/β-TCP groups with significant improvements over control and 0.1% rh-FGF-2/β-TCP groups. The success rate at 6 mo was 71% in the 2 higher-concentration groups, as compared with 45% in the control and lowest treatment groups. Percentage bone fill in the 2 higher-concentration groups was 75% and 71%, compared with 63% and 61% in the control and lowest treatment group. No increases in specific antibody to rh-FGF-2 were detected, and no serious adverse events related to the products were reported. The results from this multicenter trial demonstrated that the treatment of infrabony vertical periodontal defects can be enhanced with the addition of rh-FGF-2/β-TCP (ClinicalTrials.gov NCT01728844). © International & American Associations for Dental Research 2016.
ICSH guidelines for the verification and performance of automated cell counters for body fluids.
Bourner, G; De la Salle, B; George, T; Tabe, Y; Baum, H; Culp, N; Keng, T B
2014-12-01
One of the many challenges facing laboratories is the verification of their automated Complete Blood Count cell counters for the enumeration of body fluids. These analyzers offer improved accuracy, precision, and efficiency in performing the enumeration of cells compared with manual methods. A patterns of practice survey was distributed to laboratories that participate in proficiency testing in Ontario, Canada, the United States, the United Kingdom, and Japan to determine the number of laboratories that are testing body fluids on automated analyzers and the performance specifications that were performed. Based on the results of this questionnaire, an International Working Group for the Verification and Performance of Automated Cell Counters for Body Fluids was formed by the International Council for Standardization in Hematology (ICSH) to prepare a set of guidelines to help laboratories plan and execute the verification of their automated cell counters to provide accurate and reliable results for automated body fluid counts. These guidelines were discussed at the ICSH General Assemblies and reviewed by an international panel of experts to achieve further consensus. © 2014 John Wiley & Sons Ltd.
Murias, Juan M; Pogliaghi, Silvia; Paterson, Donald H
2018-01-01
The accuracy of an exhaustive ramp incremental (RI) test to determine maximal oxygen uptake ([Formula: see text]O 2max ) was recently questioned and the utilization of a verification phase proposed as a gold standard. This study compared the oxygen uptake ([Formula: see text]O 2 ) during a RI test to that obtained during a verification phase aimed to confirm attainment of [Formula: see text]O 2max . Sixty-one healthy males [31 older (O) 65 ± 5 yrs; 30 younger (Y) 25 ± 4 yrs] performed a RI test (15-20 W/min for O and 25 W/min for Y). At the end of the RI test, a 5-min recovery period was followed by a verification phase of constant load cycling to fatigue at either 85% ( n = 16) or 105% ( n = 45) of the peak power output obtained from the RI test. The highest [Formula: see text]O 2 after the RI test (39.8 ± 11.5 mL·kg -1 ·min -1 ) and the verification phase (40.1 ± 11.2 mL·kg -1 ·min -1 ) were not different ( p = 0.33) and they were highly correlated ( r = 0.99; p < 0.01). This response was not affected by age or intensity of the verification phase. The Bland-Altman analysis revealed a very small absolute bias (-0.25 mL·kg -1 ·min -1 , not different from 0) and a precision of ±1.56 mL·kg -1 ·min -1 between measures. This study indicated that a verification phase does not highlight an under-estimation of [Formula: see text]O 2max derived from a RI test, in a large and heterogeneous group of healthy younger and older men naïve to laboratory testing procedures. Moreover, only minor within-individual differences were observed between the maximal [Formula: see text]O 2 elicited during the RI and the verification phase. Thus a verification phase does not add any validation of the determination of a [Formula: see text]O 2max . Therefore, the recommendation that a verification phase should become a gold standard procedure, although initially appealing, is not supported by the experimental data.
Tolerance measurements on internal- and external-hexagon implants.
Braian, Michael; De Bruyn, Hugo; Fransson, Håkan; Christersson, Cecilia; Wennerberg, Ann
2014-01-01
To measure the horizontal machining tolerances of the interface between internal- and external-hexagon implants and analogs with corresponding components after delivery from the manufacturer. These values may be a valuable tool for evaluating increasing misfit caused by fabrication, processing, and wear. Seven implants and seven analogs with external- and internal-hexagon connections (Biomet 3i) with corresponding prefabricated gold cylinders and gold screws, prefabricated cylindric plastic cylinders, and laboratory screws were studied. One set of components from the external and internal groups was measured manually and digitally. Measurements from the test subjects were compared with identical measurements from the virtual model to obtain threshold values. The virtual model was then used to obtain optimally oriented cuts. The horizontal machining tolerances for castable plastic abutments on external implants were 12 ± 89 μm, and for internal implants they were 86 ± 47 μm. Tolerance measurements on prefabricated gold abutments for external implants were 44 ± 9 μm, and for internal implants they were 58 ± 28 μm. The groups with metallic components showed the smallest tolerance at < 50 μm for the external group and < 90 μm for the internal group. The prefabricated plastic cylinder groups ranged from < 100 μm for external and < 130 μm for internal connection.
He, Xin-fang; Xu, Hai-bin
2006-08-01
To observe the increasing effect of Yanglingquan (GB 34) on sprain of external ankle joint. Seventy-nine cases of sprain of external ankle joint were semi-randomly divided into a treatment group (n = 46) and a control group (n = 33). The treatment group were treated with acupuncture at Yanglingquan (GB 34) and electro-magnetic therapy at local acupoints, and the control group with electro-magnetic therapy. The cured rate and the total effective rate were 67.4% and 91.3% in the treatment group, and 36.4% and 69.7% in the control group, respectively, with a significant difference between the two groups (P<0.01, P<0.05). Acupuncture at Yanglingquan (GB 34) has a better therapeutic effect on sprain of the external ankle joint.
Emara, Khaled; El Moatasem, El Hussein; El Shazly, Ossama
2011-12-01
Complex foot deformity is a multi-planar foot deformity with many etiologic factors. Different corrective procedures using Ilizarov external fixation have been described which include, soft tissue release, V-osteotomy, multiple osteotomies and triple fusion. In this study we compare the results of two groups of skeletally mature patients with complex foot deformity who were treated by two different protocols. The first group (27 patients, 29 feet) was treated by triple fusion fixed by Ilizarov external fixator until union. The second group (29 patients, 30 feet), was treated by triple fusion with initial fixation by Ilizarov external fixation until correction of the deformity was achieved clinically, and then the Ilizarov fixation was replaced by internal fixation using percutaneous screws. Both groups were compared as regard the surgical outcome and the incidence of complications. There was statistically significant difference between the two groups regarding duration of external fixation and duration of casting with shorter duration in the group 2. Also there was statistically significant difference between both groups regarding pin tract infection with less incidence in group 2. Early removal of Ilizarov external fixation after correction of the deformity and percutaneous internal fixation using 6.5 cannulated screws can shorten the duration of treatment and be more comfortable for the patient with a low risk of recurrence or infection. Copyright © 2010 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Rahman, Md Mushfiqur; Lei, Yu; Kalantzis, Georgios
2018-01-01
Quality Assurance (QA) for medical linear accelerator (linac) is one of the primary concerns in external beam radiation Therapy. Continued advancements in clinical accelerators and computer control technology make the QA procedures more complex and time consuming which often, adequate software accompanied with specific phantoms is required. To ameliorate that matter, we introduce QALMA (Quality Assurance for Linac with MATLAB), a MALAB toolkit which aims to simplify the quantitative analysis of QA for linac which includes Star-Shot analysis, Picket Fence test, Winston-Lutz test, Multileaf Collimator (MLC) log file analysis and verification of light & radiation field coincidence test.
Experiment to measure vacuum birefringence: Conceptual design
NASA Astrophysics Data System (ADS)
Mueller, Guido; Tanner, David; Doebrich, Babette; Poeld, Jan; Lindner, Axel; Willke, Benno
2016-03-01
Vacuum birefringence is another lingering challenge which will soon become accessible to experimental verification. The effect was first calculated by Euler and Heisenberg in 1936 and is these days described as a one-loop correction to the differential index of refraction between light which is polarized parallel and perpendicular to an external magnetic field. Our plan is to realize (and slightly modify) an idea which was originally published by Hall, Ye, and Ma using advanced LIGO and LISA technology and the infrastructure of the ALPS light-shining-through-walls experiment following the ALPS IIc science run. This work is supported by the Deutsche Forschungsgemeinschaft and the Heising-Simons Foundation.
Experimental verification of rank 1 chaos in switch-controlled Chua circuit.
Oksasoglu, Ali; Ozoguz, Serdar; Demirkol, Ahmet S; Akgul, Tayfun; Wang, Qiudong
2009-03-01
In this paper, we provide the first experimental proof for the existence of rank 1 chaos in the switch-controlled Chua circuit by following a step-by-step procedure given by the theory of rank 1 maps. At the center of this procedure is a periodically kicked limit cycle obtained from the unforced system. Then, this limit cycle is subjected to periodic kicks by adding externally controlled switches to the original circuit. Both the smooth nonlinearity and the piecewise linear cases are considered in this experimental investigation. Experimental results are found to be in concordance with the conclusions of the theory.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-14
... (Missile Technology Control Regime, Australia Group, Chemical Weapons Convention, Nuclear Suppliers Group... of weapons of mass destruction (WMD) or cruise or ballistic missile systems. The latter category... or cruise or ballistic missile systems, (b) other items with the potential of making such a material...
Schrauf, Robert W.
2013-01-01
This research focuses on patterns of English proficiency and use-of-English among older immigrants living in linguistically concentrated, ethnic neighborhoods. A sample (n=60) of older Puerto Ricans, who moved from the island to the mainland in their twenties, were divided into English proficiency groups (fluent, high intermediate, low intermediate) via the Adult Language Assessment Scales. Participants then provided self-ratings of their English proficiency (understanding, speaking, reading, and writing), their use of English in social domains (language spoken with own-family, in-laws, spouse, children, neighbors, and workmates), and their use of English in private psychological domains (language of talking to oneself, counting, writing notes to oneself, thinking, dreaming, praying, and expressing feelings). Finally, all participants completed the Puerto Rican Bicultural Scale. Results show a cohort of immigrant elders whose first language is protected by their ethnic neighborhoods but whose domestic and private lives are increasingly permeated by English. In particular, children emerge as powerful forces of language socialization in English for their parents. Further, there are important individual differences by level of proficiency, with a lowest proficiency group that is less acculturated, lower in socioeconomic status, and even more linguistically isolated than groups with higher proficiency. In essence, level of second language proficiency is a potent source of intracultural variation. Methodologically, the paper makes the important point that self-rated patterns of language use are consistent with scores on formal measures of proficiency. The paper also provides empirical verification of the logic of dividing language use into external, social speech and internal, psychological speech. PMID:19184621
Etiologic analysis of 100 anatomically failed dacryocystorhinostomies
Dave, Tarjani Vivek; Mohammed, Faraz Ali; Ali, Mohammad Javed; Naik, Milind N
2016-01-01
Background The aim of this study was to assess the etiological factors contributing to the failure of a dacryocystorhinostomy (DCR). Patients and methods Retrospective review was performed in 100 consecutive patients who were diagnosed with anatomically failed DCR at presentation to a tertiary care hospital over a 5-year period from 2010 to 2015. Patient records were reviewed for demographic data, type of past surgery, preoperative endoscopic findings, previous use of adjuvants such as intubation and mitomycin C, and intraoperative notes during the re-revision. The potential etiological factors for failure were noted. Results Of the 100 patients with failed DCRs, the primary surgery was an external DCR in 73 and endoscopic DCR in 27 patients. Six patients in each group had multiple revisions. The mean ages at presentation in the external and endoscopic groups were 39.41 years and 37.19 years, respectively. All patients presented with epiphora. The most common causes of failure were inadequate osteotomy (69.8% in the external group and 85.1% in the endoscopic group, P=0.19) followed by inadequate or inappropriate sac marsupialization (60.2% in the external group and 77.7% in the endoscopic group, P=0.16) and cicatricial closure of the ostium (50.6% in the external group and 55.5% in the endoscopic group, P=0.83). The least common causes such as ostium granulomas and paradoxical middle turbinate (1.37%, n=1) were noted in the external group only. Conclusion Inadequate osteotomy, incomplete sac marsupialization, and cicatricial closure of the ostium were the most common causes of failure and did not significantly differ in the external and endoscopic groups. Meticulous evaluation to identify causative factors for failure and addressing them are crucial for subsequent successful outcomes. PMID:27555748
Miften, Moyed; Olch, Arthur; Mihailidis, Dimitris; Moran, Jean; Pawlicki, Todd; Molineu, Andrea; Li, Harold; Wijesooriya, Krishni; Shi, Jie; Xia, Ping; Papanikolaou, Nikos; Low, Daniel A
2018-04-01
Patient-specific IMRT QA measurements are important components of processes designed to identify discrepancies between calculated and delivered radiation doses. Discrepancy tolerance limits are neither well defined nor consistently applied across centers. The AAPM TG-218 report provides a comprehensive review aimed at improving the understanding and consistency of these processes as well as recommendations for methodologies and tolerance limits in patient-specific IMRT QA. The performance of the dose difference/distance-to-agreement (DTA) and γ dose distribution comparison metrics are investigated. Measurement methods are reviewed and followed by a discussion of the pros and cons of each. Methodologies for absolute dose verification are discussed and new IMRT QA verification tools are presented. Literature on the expected or achievable agreement between measurements and calculations for different types of planning and delivery systems are reviewed and analyzed. Tests of vendor implementations of the γ verification algorithm employing benchmark cases are presented. Operational shortcomings that can reduce the γ tool accuracy and subsequent effectiveness for IMRT QA are described. Practical considerations including spatial resolution, normalization, dose threshold, and data interpretation are discussed. Published data on IMRT QA and the clinical experience of the group members are used to develop guidelines and recommendations on tolerance and action limits for IMRT QA. Steps to check failed IMRT QA plans are outlined. Recommendations on delivery methods, data interpretation, dose normalization, the use of γ analysis routines and choice of tolerance limits for IMRT QA are made with focus on detecting differences between calculated and measured doses via the use of robust analysis methods and an in-depth understanding of IMRT verification metrics. The recommendations are intended to improve the IMRT QA process and establish consistent, and comparable IMRT QA criteria among institutions. © 2018 American Association of Physicists in Medicine.
Effect of different external attention of focus instruction on learning of golf putting skill.
Shafizadeh, Mohsen; McMorris, Terry; Sproule, John
2011-10-01
The effect of different sources of external attentional focus on learning a motor skill was assessed in the present study. 30 students (12 men, 18 women) participated voluntarily and were divided, according to type of external focus, into target, club swing, and target-club swing groups. The task was a golf putting skill. The target focus group attended to the target (hole), the club swing focus group attended to the execution of the club's swing, and the target-club swing focus group attended to both. All participants performed 50 trials of the putting skill in the acquisition phase and 10 trials in the 24-hr. delayed retention phase. The dependent variable was the error in the putting skill measured as the distance from the hole to the ball after each strike. Results showed the target-club swing focus group had better scores in the acquisition and retention phases than the other groups. It was concluded that external focus instruction helped the learners to integrate target cue with action cue and is more effective in skill learning than other external-focus instructions. These results support the claims of ecological psychology theorists concerning the effects of external focus of attention.
Internal and External Imagery Effects on Tennis Skills Among Novices.
Dana, Amir; Gozalzadeh, Elmira
2017-10-01
The purpose of this study was to determine the effects of internal and external visual imagery perspectives on performance accuracy of open and closed tennis skills (i.e., serve, forehand, and backhand) among novices. Thirty-six young male novices, aged 15-18 years, from a summer tennis program participated. Following initial skill acquisition (12 sessions), baseline assessments of imagery ability and imagery perspective preference were used to assign participants to one of three groups: internal imagery ( n = 12), external imagery ( n = 12), or a no-imagery (mental math exercise) control group ( n = 12). The experimental interventions of 15 minutes of mental imagery (internal or external) or mental math exercises followed by 15 minutes of physical practice were held three times a week for six weeks. The performance accuracy of the groups on the serve, forehand, and backhand strokes was measured at pre- and post-test using videotaping. Results showed significant increases in the performance accuracy of all three tennis strokes in all three groups, but serve accuracy in the internal imagery group and forehand accuracy in the external imagery group showed greater improvements, while backhand accuracy was similarly improved in all three groups. These findings highlight differential efficacy of internal and external visual imagery for performance improvement on complex sport skills in early stage motor learning.
Source position verification and dosimetry in HDR brachytherapy using an EPID.
Smith, R L; Taylor, M L; McDermott, L N; Haworth, A; Millar, J L; Franich, R D
2013-11-01
Accurate treatment delivery in high dose rate (HDR) brachytherapy requires correct source dwell positions and dwell times to be administered relative to each other and to the surrounding anatomy. Treatment delivery inaccuracies predominantly occur for two reasons: (i) anatomical movement or (ii) as a result of human errors that are usually related to incorrect implementation of the planned treatment. Electronic portal imaging devices (EPIDs) were originally developed for patient position verification in external beam radiotherapy and their application has been extended to provide dosimetric information. The authors have characterized the response of an EPID for use with an (192)Ir brachytherapy source to demonstrate its use as a verification device, providing both source position and dosimetric information. Characterization of the EPID response using an (192)Ir brachytherapy source included investigations of reproducibility, linearity with dose rate, photon energy dependence, and charge build-up effects associated with exposure time and image acquisition time. Source position resolution in three dimensions was determined. To illustrate treatment verification, a simple treatment plan was delivered to a phantom and the measured EPID dose distribution compared with the planned dose. The mean absolute source position error in the plane parallel to the EPID, for dwells measured at 50, 100, and 150 mm source to detector distances (SDD), was determined to be 0.26 mm. The resolution of the z coordinate (perpendicular distance from detector plane) is SDD dependent with 95% confidence intervals of ± 0.1, ± 0.5, and ± 2.0 mm at SDDs of 50, 100, and 150 mm, respectively. The response of the EPID is highly linear to dose rate. The EPID exhibits an over-response to low energy incident photons and this nonlinearity is incorporated into the dose calibration procedure. A distance (spectral) dependent dose rate calibration procedure has been developed. The difference between measured and planned dose is less than 2% for 98.0% of pixels in a two-dimensional plane at an SDD of 100 mm. Our application of EPID dosimetry to HDR brachytherapy provides a quality assurance measure of the geometrical distribution of the delivered dose as well as the source positions, which is not possible with any current HDR brachytherapy verification system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ding, X; Witztum, A; Kenton, O
2014-06-01
Purpose: Due to the unpredictability of bowel gas movement, the PA beam direction is always favored for robust proton therapy in post-operative pancreatic cancer treatment. We investigate the feasibility of replacing PA beam with a modified AP beam to take the bowel gas uncertainty into account. Methods: Nine post-operative pancreatic cancer patients treated with proton therapy (5040cGy, 28 fractions) in our institution were randomly selected. The original plan uses PA and lateral direction passive-scattering proton beams. Beam weighting is about 1:1. All patients received weekly verification CTs to assess the daily variations(total 17 verification CTs). The PA direction beam wasmore » replaced by two other groups of AP direction beam. Group AP: takes 3.5% range uncertainty into account. Group APmod: compensates the bowel gas uncertainty by expanding the proximal margin to 2cm more. The 2cm margin was acquired from the average bowel diameter in from 100 adult abdominal CT scans near pancreatic region (+/- 5cm superiorly and inferiorly). Dose Volume Histograms(DVHs) of the verification CTs were acquired for robustness study. Results: Without the lateral beam, Group APmod is as robust as Group PA. In Group AP, more than 10% of iCTV D98/D95 were reduced by 4–8%. LT kidney and Liver dose robustness are not affected by the AP/PA beam direction. There is 10% of chance that RT kidney and cord will be hit by AP proton beam due to the bowel gas. Compared to Group PA, APmod plan reduced the dose to kidneys and cord max significantly, while there is no statistical significant increase in bowel mean dose. Conclusion: APmod proton beam for the target coverage could be as robust as the PA direction without sacrificing too much of bowel dose. When the AP direction beam has to be selected, a 2cm proximal margin should be considered.« less
NASA Astrophysics Data System (ADS)
Da Silva, A.; Sánchez Prieto, S.; Polo, O.; Parra Espada, P.
2013-05-01
Because of the tough robustness requirements in space software development, it is imperative to carry out verification tasks at a very early development stage to ensure that the implemented exception mechanisms work properly. All this should be done long time before the real hardware is available. But even if real hardware is available the verification of software fault tolerance mechanisms can be difficult since real faulty situations must be systematically and artificially brought about which can be imposible on real hardware. To solve this problem the Alcala Space Research Group (SRG) has developed a LEON2 virtual platform (Leon2ViP) with fault injection capabilities. This way it is posible to run the exact same target binary software as runs on the physical system in a more controlled and deterministic environment, allowing a more strict requirements verification. Leon2ViP enables unmanned and tightly focused fault injection campaigns, not possible otherwise, in order to expose and diagnose flaws in the software implementation early. Furthermore, the use of a virtual hardware-in-the-loop approach makes it possible to carry out preliminary integration tests with the spacecraft emulator or the sensors. The use of Leon2ViP has meant a signicant improvement, in both time and cost, in the development and verification processes of the Instrument Control Unit boot software on board Solar Orbiter's Energetic Particle Detector.
Verification and Validation of Flight-Critical Systems
NASA Technical Reports Server (NTRS)
Brat, Guillaume
2010-01-01
For the first time in many years, the NASA budget presented to congress calls for a focused effort on the verification and validation (V&V) of complex systems. This is mostly motivated by the results of the VVFCS (V&V of Flight-Critical Systems) study, which should materialize as a a concrete effort under the Aviation Safety program. This talk will present the results of the study, from requirements coming out of discussions with the FAA and the Joint Planning and Development Office (JPDO) to technical plan addressing the issue, and its proposed current and future V&V research agenda, which will be addressed by NASA Ames, Langley, and Dryden as well as external partners through NASA Research Announcements (NRA) calls. This agenda calls for pushing V&V earlier in the life cycle and take advantage of formal methods to increase safety and reduce cost of V&V. I will present the on-going research work (especially the four main technical areas: Safety Assurance, Distributed Systems, Authority and Autonomy, and Software-Intensive Systems), possible extensions, and how VVFCS plans on grounding the research in realistic examples, including an intended V&V test-bench based on an Integrated Modular Avionics (IMA) architecture and hosted by Dryden.
Bradley, David; Nisbet, Andrew
2012-01-01
This study provides a review of recent publications on the physics-aspects of dosimetric accuracy in high dose rate (HDR) brachytherapy. The discussion of accuracy is primarily concerned with uncertainties, but methods to improve dose conformation to the prescribed intended dose distribution are also noted. The main aim of the paper is to review current practical techniques and methods employed for HDR brachytherapy dosimetry. This includes work on the determination of dose rate fields around brachytherapy sources, the capability of treatment planning systems, the performance of treatment units and methods to verify dose delivery. This work highlights the determinants of accuracy in HDR dosimetry and treatment delivery and presents a selection of papers, focusing on articles from the last five years, to reflect active areas of research and development. Apart from Monte Carlo modelling of source dosimetry, there is no clear consensus on the optimum techniques to be used to assure dosimetric accuracy through all the processes involved in HDR brachytherapy treatment. With the exception of the ESTRO mailed dosimetry service, there is little dosimetric audit activity reported in the literature, when compared with external beam radiotherapy verification. PMID:23349649
2013-01-01
Background A Drug Influence Evaluation (DIE) is a formal assessment of an impaired driving suspect, performed by a trained law enforcement officer who uses circumstantial facts, questioning, searching, and a physical exam to form an unstandardized opinion as to whether a suspect’s driving was impaired by drugs. This paper first identifies the scientific studies commonly cited in American criminal trials as evidence of DIE accuracy, and second, uses the QUADAS tool to investigate whether the methodologies used by these studies allow them to correctly quantify the diagnostic accuracy of the DIEs currently administered by US law enforcement. Results Three studies were selected for analysis. For each study, the QUADAS tool identified biases that distorted reported accuracies. The studies were subject to spectrum bias, selection bias, misclassification bias, verification bias, differential verification bias, incorporation bias, and review bias. The studies quantified DIE performance with prevalence-dependent accuracy statistics that are internally but not externally valid. Conclusion The accuracies reported by these studies do not quantify the accuracy of the DIE process now used by US law enforcement. These studies do not validate current DIE practice. PMID:24188398
NASA Astrophysics Data System (ADS)
Fontanarosa, Davide; van der Meer, Skadi; Bamber, Jeffrey; Harris, Emma; O'Shea, Tuathan; Verhaegen, Frank
2015-02-01
In modern radiotherapy, verification of the treatment to ensure the target receives the prescribed dose and normal tissues are optimally spared has become essential. Several forms of image guidance are available for this purpose. The most commonly used forms of image guidance are based on kilovolt or megavolt x-ray imaging. Image guidance can also be performed with non-harmful ultrasound (US) waves. This increasingly used technique has the potential to offer both anatomical and functional information. This review presents an overview of the historical and current use of two-dimensional and three-dimensional US imaging for treatment verification in radiotherapy. The US technology and the implementation in the radiotherapy workflow are described. The use of US guidance in the treatment planning process is discussed. The role of US technology in inter-fraction motion monitoring and management is explained, and clinical studies of applications in areas such as the pelvis, abdomen and breast are reviewed. A companion review paper (O’Shea et al 2015 Phys. Med. Biol. submitted) will extensively discuss the use of US imaging for intra-fraction motion quantification and novel applications of US technology to RT.
Fontanarosa, Davide; van der Meer, Skadi; Bamber, Jeffrey; Harris, Emma; O'Shea, Tuathan; Verhaegen, Frank
2015-02-07
In modern radiotherapy, verification of the treatment to ensure the target receives the prescribed dose and normal tissues are optimally spared has become essential. Several forms of image guidance are available for this purpose. The most commonly used forms of image guidance are based on kilovolt or megavolt x-ray imaging. Image guidance can also be performed with non-harmful ultrasound (US) waves. This increasingly used technique has the potential to offer both anatomical and functional information.This review presents an overview of the historical and current use of two-dimensional and three-dimensional US imaging for treatment verification in radiotherapy. The US technology and the implementation in the radiotherapy workflow are described. The use of US guidance in the treatment planning process is discussed. The role of US technology in inter-fraction motion monitoring and management is explained, and clinical studies of applications in areas such as the pelvis, abdomen and breast are reviewed. A companion review paper (O'Shea et al 2015 Phys. Med. Biol. submitted) will extensively discuss the use of US imaging for intra-fraction motion quantification and novel applications of US technology to RT.
Environment Modeling Using Runtime Values for JPF-Android
NASA Technical Reports Server (NTRS)
van der Merwe, Heila; Tkachuk, Oksana; Nel, Seal; van der Merwe, Brink; Visser, Willem
2015-01-01
Software applications are developed to be executed in a specific environment. This environment includes external native libraries to add functionality to the application and drivers to fire the application execution. For testing and verification, the environment of an application is simplified abstracted using models or stubs. Empty stubs, returning default values, are simple to generate automatically, but they do not perform well when the application expects specific return values. Symbolic execution is used to find input parameters for drivers and return values for library stubs, but it struggles to detect the values of complex objects. In this work-in-progress paper, we explore an approach to generate drivers and stubs based on values collected during runtime instead of using default values. Entry-points and methods that need to be modeled are instrumented to log their parameters and return values. The instrumented applications are then executed using a driver and instrumented libraries. The values collected during runtime are used to generate driver and stub values on- the-fly that improve coverage during verification by enabling the execution of code that previously crashed or was missed. We are implementing this approach to improve the environment model of JPF-Android, our model checking and analysis tool for Android applications.
Palmer, Antony; Bradley, David; Nisbet, Andrew
2012-06-01
This study provides a review of recent publications on the physics-aspects of dosimetric accuracy in high dose rate (HDR) brachytherapy. The discussion of accuracy is primarily concerned with uncertainties, but methods to improve dose conformation to the prescribed intended dose distribution are also noted. The main aim of the paper is to review current practical techniques and methods employed for HDR brachytherapy dosimetry. This includes work on the determination of dose rate fields around brachytherapy sources, the capability of treatment planning systems, the performance of treatment units and methods to verify dose delivery. This work highlights the determinants of accuracy in HDR dosimetry and treatment delivery and presents a selection of papers, focusing on articles from the last five years, to reflect active areas of research and development. Apart from Monte Carlo modelling of source dosimetry, there is no clear consensus on the optimum techniques to be used to assure dosimetric accuracy through all the processes involved in HDR brachytherapy treatment. With the exception of the ESTRO mailed dosimetry service, there is little dosimetric audit activity reported in the literature, when compared with external beam radiotherapy verification.
Vieira, Gabriel de Deus; Basano, Sergio de Almeida; Camargo, Luís Marcelo Aranha
2016-01-01
The morbidity and mortality profile in a given region reflects its quality of life and provides tools for improving public health policies in that region. A cross-sectional epidemiological study was performed using secondary mortality data collected from the Monte Negro municipality of the Brazilian Western Amazon from 2000 to 2011. These data were compared with data from similar municipalities in other Brazilian macro-regions. Data were obtained through the Departamento de Informática do Sistema Único de Saúde (DATASUS) information system. The number of deaths reported over the study period was 606. The most common cause of death was external causes of morbidity and mortality [International Classification of Diseases (ICD)-10 chapter 20], followed by diseases of the circulatory system (ICD-10 chapter 9). Among the causes of death according to age group, infectious and parasitic diseases were the most common for 2- to 9-year-old children; external causes of disease were the most prevalent for 10- to 59-year-old people; and circulatory diseases prevailed in individuals over 60 years of age. Eleven percent of deaths were due to unknown causes. These results point to a fragility in the public policies for prevention and awareness of this problem. Infectious and parasitic diseases contribute only 4.5% of deaths, but had the third highest Disability-Adjusted Life Year score (1,190 days). Improving support to the Estratégia Saúde da Família (Family Health Strategy) program and implementing a death verification service would significantly aid in reducing the occurrence of non-transmissible chronic diseases and clarifying unknown causes of death.
Kuzmina, Irina; Ekstrand, Kim R
2015-08-01
To report the long-term effect (18 years) of the Nexö-method, initially implemented in groups of children in Moscow in 1994. Three groups of children were included in the initial study in 1994. This study is a follow-up study of two of the three initial groups: a group of 6-year-olds (test group6 ; control group6 ) and a group of 11-year-olds (test group11 , control group11) , n = 50 individuals in each of the four subgroups. In 2012, >80% of the participants in the two groups (now aged 24 and 28 years old) were re-examined by the original examiner, who was blinded to which group the patients had belonged in the initial study. After re-examination, the participants were interviewed by a person not otherwise attached to the study. Finally, caries data were collected from 100 24-year-olds and 100 28-year-olds who attended the dental school (50%) and private clinic (50%) in Moscow (External control groups24,28 ). The outcome variables of the study were plaque and gingival status, and DMFT/S. In 2012, the control groups24,28 displayed significantly higher plaque scores than the test groups24,28 (P-values < 0.05). No differences were seen regarding gingivitis scores (P-values > 0.41). Mean DMFT/S in 2012 was test group24 = 6.98/10.51, control group24 = 8.84/13.14 (P = 0.02/0.06). External control group24 = 8.89/15.86 (test24 versus external control group24 , P = 0.01/0.007; control24 versus external control group24 , P = 0.94/0.16). Test group28 = 6.74/10.83, control group28 = 8.70/14.48 (P = 0.02/0.008). External control group28 = 9.03/18.06 (test28 versus external control28 , P = 0.03/0.001; control28 versus external control28 , P = 0.68/0.07). The interview indicated that the participants in the test groups were more aware of factors that are considered important for control of caries than participants in the control groups. The data from this group of Moscow citizens suggest a long-term positive effect of the Nexö-method implemented during childhood. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Mullen, Richard; Faull, Andrea; Jones, Eleri S; Kingston, Kieran
2012-01-01
Previous studies have demonstrated that an external focus can enhance motor learning compared to an internal focus. The benefits of adopting an external focus are attributed to the use of less effortful automatic control processes, while an internal focus relies upon more effort-intensive consciously controlled processes. The aim of this study was to compare the effectiveness of a distal external focus with an internal focus in the acquisition of a simulated driving task and subsequent performance in a competitive condition designed to increase state anxiety. To provide further evidence for the automatic nature of externally controlled movements, the study included heart rate variability (HRV) as an index of mental effort. Sixteen participants completed eight blocks of four laps in either a distal external or internal focus condition, followed by two blocks of four laps in the competitive condition. During acquisition, the performance of both groups improved; however, the distal external focus group outperformed the internal focus group. The poorer performance of the internal focus group was accompanied by a larger reduction in HRV, indicating a greater investment of mental effort. In the competition condition, state anxiety increased, and for both groups, performance improved as a function of the increased anxiety. Increased heart rate and self-reported mental effort accompanied the performance improvement. The distal external focus group also outperformed the internal focus group across both neutral and competitive conditions and this more effective performance was again associated with lower levels of HRV. Overall, the results offer support for the suggestion that an external focus promotes a more automatic mode of functioning. In the competitive condition, both foci enhanced performance and while the improved performance may have been achieved at the expense of greater compensatory mental effort, this was not reflected in HRV scores.
Yeoh, David; Goddard, Richard; Macnamara, Paul; Bowman, Nicholas; Miles, Kim; East, Debra; Butler-Manuel, Adrian
2008-08-01
The most common indication for knee arthrodesis is pain and instability in an unreconstructable knee following an infected knee arthroplasty. In this study, we compare the use of the Mayday arthrodesis nail (Orthodynamics, Christchurch, UK) versus external fixation, Orthofix (Berkshire UK) and Stryker Hoffman II (County Cork, Ireland). All patients in this study underwent arthrodesis between 1995 and 2006 at Conquest Hospital, Hastings. In group A, 11 patients underwent arthrodesis with a Mayday nail. In all cases, the indications were infected total knee replacements (TKR). Three of these patients previously had failed attempts at arthrodesis with external fixation devices. In group B, seven patients underwent arthrodesis using external fixation. In six patients, the indication was infected TKRs. Results were reviewed retrospectively, with union assessed both clinically and radiologically. The mean inpatient stay for the Mayday nail group was 23 days (range 8-45 days) compared with 76 days (range 34-122) for the external fixation group (p<0.01, CI 95). Ten patients in group A went on to confirmed primary arthrodesis. One patient underwent revision arthrodesis with a Mayday nail and subsequently united. In group B only two patients achieved union. The rate of union was significantly greater in the Mayday nail group than the external fixation group (91% vs 29%, p<0.01). Of those patients that achieved union, there was no difference in the time to fusion between groups. Our study supported the existing literature and found that the Mayday nail appeared more effective than monoaxial external fixators for arthrodesis in the management of infected total knee replacements.
Duan, Da-Peng; You, Wu-Lin; Ji, Le; Zhang, Yong-Tao; Dang, Xiao-Qian; Wang, Kun-Zheng
2014-01-01
To analyze the effects of three surgical operations in the treatment of Pilon fracture of Rüedi-Allgower type III, and put forward the best therapeutic method. The clinical data of 33 patients with Pilon fracture who received surgical operations (plaster immobilization group, 10 cases; distal tibia anatomical plate group, 11 cases; external fixation with limited internal fixation group, 12 cases) from October 2009 to January 2012 were analyzed. There were 5 males and 5 females, ranging in age from 24 to 61 years in the plaster immobilization group. There were 7 males and 4 females, ranging in age from 21 to 64 years in the distal tibia anatomical plate group. There were 7 males and 5 females, ranging in age from 23 to 67 years in the external fixation with limited internal fixation group. The Ankle X-ray of Pilon fracture after operation, ankle score, early and late complications were collected. Bourne system was used to evaluate ankle joint function. After 8 months to 3 years follow-up, it was found that three kinds of treatment had significant differences in the outcomes and complications (P < 0.05): the external fixation with limited internal fixation group got the best results. The number of anatomic reduction cases in the external fixation with limited internal fixation group (7 cases) and the distal tibia anatomical plate group (8 cases) was more than the plaster immobilization group (2 cases). According to the ankle score, 8 patients got an excellent result, 3 good and 1 poor in the limited internal fixation group ,which was better than those of distal tibia anatomical plate group (5 excellent, 4 good and 2 poor) and the plaster immobilization group (3 excellent, 4 good and 3 poor). The number of early and late complications in the external fixation with limited internal fixation group was more than those in the plaster immobilization group and the distal tibia anatomical plate group (P< 0.05). Treatment of external fixation with limited internal fixation in the treatment of Pilon fracture of Rüedi-Allgower type III is effective and safe.
Wu, Gang; Luo, Xiaozhong; Tan, Lun; Lin, Xu; Wu, Chao; Guo, Yong; Zhong, Zewei
2013-11-01
To compare the clinical results of locking compress plate (LCP) as an external fixator and standard external fixator for treatment of tibial open fractures. Between May 2009 and June 2012, 59 patients with tibial open fractures were treated with LCP as an external fixator in 36 patients (group A), and with standard external fixator in 23 patients (group B). There was no significant difference in gender, age, cause of injury, affected side, type of fracture, location, and interval between injury and surgery between 2 groups (P > 0.05). The time of fracture healing and incision healing, the time of partial weight-bearing, the range of motion (ROM) of knee and ankle, and complications were compared between 2 groups. The incidence of pin-track infection in group A (0) was significantly lower than that in group B (21.7%) (P=0.007). No significant difference was found in the incidence of superficial infection and deep infection of incision, and the time of incision healing between 2 groups (P > 0.05). Deep vein thrombosis occurred in 5 cases of group A and 2 cases of group B, showing no significant difference (Chi(2)=0.036, P=0.085). All patients were followed up 15.2 months on average (range, 9-28 months) in group A, and 18.6 months on average (range, 9-47 months) in group B. The malunion rate and nonunion rate showed no significant difference between groups A and B (0 versus 13.0% and 0 versus 8.7%, P > 0.05); the delayed union rate of group A (2.8%) was significantly lower than that of group B (21.7%) (Chi(2)=5.573, P=0.018). Group A had shorter time of fracture healing, quicker partial weight-bearing, greater ROM of the knee and ankle than group B (P < 0.05). The LCP external fixator can obtain reliable fixation in treating tibial open fracture, and has good patients' compliance, so it is helpful to do functional exercise, improve fracture healing and function recovery, and reduce the complication incidence.
26 CFR 54.9815-2719T - Internal claims and appeals and external review processes (temporary).
Code of Federal Regulations, 2012 CFR
2012-04-01
... external review processes for group health plans and health insurance issuers that are not grandfathered...) In general. A group health plan and a health insurance issuer offering group health insurance...). (2) Requirements for group health plans and group health insurance issuers. A group health plan and a...
26 CFR 54.9815-2719T - Internal claims and appeals and external review processes (temporary).
Code of Federal Regulations, 2011 CFR
2011-04-01
... external review processes for group health plans and health insurance issuers that are not grandfathered...) In general. A group health plan and a health insurance issuer offering group health insurance...). (2) Requirements for group health plans and group health insurance issuers. A group health plan and a...
26 CFR 54.9815-2719T - Internal claims and appeals and external review processes (temporary).
Code of Federal Regulations, 2014 CFR
2014-04-01
... external review processes for group health plans and health insurance issuers that are not grandfathered...) In general. A group health plan and a health insurance issuer offering group health insurance...). (2) Requirements for group health plans and group health insurance issuers. A group health plan and a...
26 CFR 54.9815-2719T - Internal claims and appeals and external review processes (temporary).
Code of Federal Regulations, 2013 CFR
2013-04-01
... external review processes for group health plans and health insurance issuers that are not grandfathered...) In general. A group health plan and a health insurance issuer offering group health insurance...). (2) Requirements for group health plans and group health insurance issuers. A group health plan and a...
Post-OPC verification using a full-chip pattern-based simulation verification method
NASA Astrophysics Data System (ADS)
Hung, Chi-Yuan; Wang, Ching-Heng; Ma, Cliff; Zhang, Gary
2005-11-01
In this paper, we evaluated and investigated techniques for performing fast full-chip post-OPC verification using a commercial product platform. A number of databases from several technology nodes, i.e. 0.13um, 0.11um and 90nm are used in the investigation. Although it has proven that for most cases, our OPC technology is robust in general, due to the variety of tape-outs with complicated design styles and technologies, it is difficult to develop a "complete or bullet-proof" OPC algorithm that would cover every possible layout patterns. In the evaluation, among dozens of databases, some OPC databases were found errors by Model-based post-OPC checking, which could cost significantly in manufacturing - reticle, wafer process, and more importantly the production delay. From such a full-chip OPC database verification, we have learned that optimizing OPC models and recipes on a limited set of test chip designs may not provide sufficient coverage across the range of designs to be produced in the process. And, fatal errors (such as pinch or bridge) or poor CD distribution and process-sensitive patterns may still occur. As a result, more than one reticle tape-out cycle is not uncommon to prove models and recipes that approach the center of process for a range of designs. So, we will describe a full-chip pattern-based simulation verification flow serves both OPC model and recipe development as well as post OPC verification after production release of the OPC. Lastly, we will discuss the differentiation of the new pattern-based and conventional edge-based verification tools and summarize the advantages of our new tool and methodology: 1). Accuracy: Superior inspection algorithms, down to 1nm accuracy with the new "pattern based" approach 2). High speed performance: Pattern-centric algorithms to give best full-chip inspection efficiency 3). Powerful analysis capability: Flexible error distribution, grouping, interactive viewing and hierarchical pattern extraction to narrow down to unique patterns/cells.
Vasiliadis, Elias S; Grivas, Theodoros B; Psarakis, Spyridon A; Papavasileiou, Evangelos; Kaspiris, Angelos; Triantafyllopoulos, Georgios
2009-01-01
Background Treatment of distal tibial intra-articular fractures is challenging due to the difficulties in achieving anatomical reduction of the articular surface and the instability which may occur due to ligamentous and soft tissue injury. The purpose of this study is to present an algorithm in the application of external fixation in the management of intra-articular fractures of the distal tibia either from axial compression or from torsional forces. Materials and methods Thirty two patients with intra-articular fractures of the distal tibia have been studied. Based on the mechanism of injury they were divided into two groups. Group I includes 17 fractures due to axial compression and group II 15 fractures due to torsional force. An Ilizarov external fixation was used in 15 patients (11 of group I and 4 of group II). In 17 cases (6 of group I and 11 of group II) a unilateral hinged external fixator was used. In 7 out of 17 fractures of group I an additional fixation of the fibula was performed. Results All fractures were healed. The mean time of removal of the external fixator was 11 weeks for group I and 10 weeks for group II. In group I, 5 patients had radiological osteoarthritic lesions (grade III and IV) but only 2 were symptomatic. Delayed union occurred in 3 patients of group I with fixed fibula. Other complications included one patient of group II with subluxation of the ankle joint after removal of the hinged external fixator, in 2 patients reduction found to be insufficient during the postoperative follow up and were revised and 6 patients had a residual pain. The range of ankle joint motion was larger in group II. Conclusion Intra-articular fractures of the distal tibia due to axial compression are usually complicated with cartilaginous problems and are requiring anatomical reduction of the articular surface. Fractures due to torsional forces are complicated with ankle instability and reduction should be augmented with ligament repair, in order to restore normal movement of talus against the mortise. Both Ilizarov and hinged external fixators are unable to restore ligamentous stability. External fixation is recommended only for fractures of the ankle joint caused by axial compression because it is biomechanically superior and has a lower complication rate. PMID:19754962
ERIC Educational Resources Information Center
London, Manuel; Polzer, Jeffrey T.; Omoregie, Heather
2005-01-01
This article presents a multilevel model of group learning that focuses on antecedents and consequences of interpersonal congruence, transactive memory, and feedback processes. The model holds that members' self-verification motives and situational conditions (e.g., member diversity and task demands) give rise to identity negotiation behaviors…
ERIC Educational Resources Information Center
Suits, Jerry P.
2004-01-01
A laboratory practical examination was used to compare the investigative skills developed in two different types of general-chemistry laboratory courses. Science and engineering majors (SEM) in the control group used a traditional verification approach (SEM-Ctrl), whereas those in the treatment group learned from an innovative, inquiry-based…
12 CFR 310.5 - Disclosure of requested information to individuals.
Code of Federal Regulations, 2013 CFR
2013-01-01
... inspection and copying by the individual (after proper identity verification as provided in § 310.4) and... choosing. (b) The FOIA/PA Group will notify, in writing, the individual making a request, whenever... record does exist, the FOIA/PA Group also will inform the individual of the system manager's decision...
12 CFR 310.5 - Disclosure of requested information to individuals.
Code of Federal Regulations, 2011 CFR
2011-01-01
... inspection and copying by the individual (after proper identity verification as provided in § 310.4) and... choosing. (b) The FOIA/PA Group will notify, in writing, the individual making a request, whenever... record does exist, the FOIA/PA Group also will inform the individual of the system manager's decision...
12 CFR 310.5 - Disclosure of requested information to individuals.
Code of Federal Regulations, 2012 CFR
2012-01-01
... inspection and copying by the individual (after proper identity verification as provided in § 310.4) and... choosing. (b) The FOIA/PA Group will notify, in writing, the individual making a request, whenever... record does exist, the FOIA/PA Group also will inform the individual of the system manager's decision...
12 CFR 310.5 - Disclosure of requested information to individuals.
Code of Federal Regulations, 2014 CFR
2014-01-01
... inspection and copying by the individual (after proper identity verification as provided in § 310.4) and... choosing. (b) The FOIA/PA Group will notify, in writing, the individual making a request, whenever... record does exist, the FOIA/PA Group also will inform the individual of the system manager's decision...
12 CFR 310.5 - Disclosure of requested information to individuals.
Code of Federal Regulations, 2010 CFR
2010-01-01
... inspection and copying by the individual (after proper identity verification as provided in § 310.4) and... choosing. (b) The FOIA/PA Group will notify, in writing, the individual making a request, whenever... record does exist, the FOIA/PA Group also will inform the individual of the system manager's decision...
Antony, Matthieu; Bertone, Maria Paola; Barthes, Olivier
2017-03-14
Results-based financing (RBF) has been introduced in many countries across Africa and a growing literature is building around the assessment of their impact. These studies are usually quantitative and often silent on the paths and processes through which results are achieved and on the wider health system effects of RBF. To address this gap, our study aims at exploring the implementation of an RBF pilot in Benin, focusing on the verification of results. The study is based on action research carried out by authors involved in the pilot as part of the agency supporting the RBF implementation in Benin. While our participant observation and operational collaboration with project's stakeholders informed the study, the analysis is mostly based on quantitative and qualitative secondary data, collected throughout the project's implementation and documentation processes. Data include project documents, reports and budgets, RBF data on service outputs and on the outcome of the verification, daily activity timesheets of the technical assistants in the districts, as well as focus groups with Community-based Organizations and informal interviews with technical assistants and district medical officers. Our analysis focuses on the actual practices of quantitative, qualitative and community verification. Results show that the verification processes are complex, costly and time-consuming, and in practice they end up differing from what designed originally. We explore the consequences of this on the operation of the scheme, on its potential to generate the envisaged change. We find, for example, that the time taken up by verification procedures limits the time available for data analysis and feedback to facility staff, thus limiting the potential to improve service delivery. Verification challenges also result in delays in bonus payment, which delink effort and reward. Additionally, the limited integration of the verification activities of district teams with their routine tasks causes a further verticalization of the health system. Our results highlight the potential disconnect between the theory of change behind RBF and the actual scheme's implementation. The implications are relevant at methodological level, stressing the importance of analyzing implementation processes to fully understand results, as well as at operational level, pointing to the need to carefully adapt the design of RBF schemes (including verification and other key functions) to the context and to allow room to iteratively modify it during implementation. They also question whether the rationale for thorough and costly verification is justified, or rather adaptations are possible.
Miller, Portia; Votruba-Drzal, Elizabeth
2017-04-01
Economic disparities in children's behavioral functioning have been observed in prior research. Yet, studies have ignored important perspectives from developmental psychopathology and have not delineated how aspects of income dynamics (i.e., cumulative family income versus income volatility) differentially relate to behavior problems. To address these limitations, the current study examined how both cumulative income and income volatility predict trajectories of children's internalizing and externalizing problems from kindergarten through fifth grade in a nationally representative sample of 10,900 children (51.4 % male). Results showed four distinct trajectories of internalizing problems and five distinct externalizing trajectories. Family income dynamics were related to trajectory group membership. Specifically, increased cumulative income decreased risk of membership in mid-increasing and mid-stable internalizing groups, and children whose families experienced multiple waves of income loss were 2.4 times as likely to be in the mid-increasing group instead of the low-stable group. With respect to externalizing, higher cumulative income increased the likelihood of belonging in the group exhibiting stably low externalizing problems. Experiencing income loss increased the risk of belonging in the trajectory group exhibiting chronically high externalizing behaviors. These results enhance our knowledge of the role of family income in the development of behavior problems.
The MCNP6 Analytic Criticality Benchmark Suite
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brown, Forrest B.
2016-06-16
Analytical benchmarks provide an invaluable tool for verifying computer codes used to simulate neutron transport. Several collections of analytical benchmark problems [1-4] are used routinely in the verification of production Monte Carlo codes such as MCNP® [5,6]. Verification of a computer code is a necessary prerequisite to the more complex validation process. The verification process confirms that a code performs its intended functions correctly. The validation process involves determining the absolute accuracy of code results vs. nature. In typical validations, results are computed for a set of benchmark experiments using a particular methodology (code, cross-section data with uncertainties, and modeling)more » and compared to the measured results from the set of benchmark experiments. The validation process determines bias, bias uncertainty, and possibly additional margins. Verification is generally performed by the code developers, while validation is generally performed by code users for a particular application space. The VERIFICATION_KEFF suite of criticality problems [1,2] was originally a set of 75 criticality problems found in the literature for which exact analytical solutions are available. Even though the spatial and energy detail is necessarily limited in analytical benchmarks, typically to a few regions or energy groups, the exact solutions obtained can be used to verify that the basic algorithms, mathematics, and methods used in complex production codes perform correctly. The present work has focused on revisiting this benchmark suite. A thorough review of the problems resulted in discarding some of them as not suitable for MCNP benchmarking. For the remaining problems, many of them were reformulated to permit execution in either multigroup mode or in the normal continuous-energy mode for MCNP. Execution of the benchmarks in continuous-energy mode provides a significant advance to MCNP verification methods.« less
Fortuin, Janna; van Geel, Mitch; Vedder, Paul
2015-04-01
Adolescents who like each other may become more similar to each other with regard to internalizing and externalizing problems, though it is not yet clear which social mechanisms explain these similarities. In this longitudinal study, we analyzed four mechanisms that may explain similarity in adolescent peer networks with regard to externalizing and internalizing problems: selection, socialization, avoidance and withdrawal. At three moments during one school-year, we asked 542 adolescents (8th grade, M-age = 13.3 years, 51 % female) to report who they liked in their classroom, and their own internalizing and externalizing problems. Adolescents tend to prefer peers who have similar externalizing problem scores, but no significant selection effect was found for internalizing problems. Adolescents who share the same group of friends socialize each other and then become more similar with respect to externalizing problems, but not with respect to internalizing problems. We found no significant effects for avoidance or withdrawal. Adolescents may choose to belong to a peer group that is similar to them in terms of externalizing problem behaviors, and through peer group socialization (e.g., enticing, modelling, mimicking, and peer pressure) become more similar to that group over time.
Hardstaff, Joanne L; Bulling, Mark T; Marion, Glenn; Hutchings, Michael R; White, Piran C L
2012-06-27
The persistence of bovine TB (bTB) in various countries throughout the world is enhanced by the existence of wildlife hosts for the infection. In Britain and Ireland, the principal wildlife host for bTB is the badger (Meles meles). The objective of our study was to examine the dynamics of bTB in badgers in relation to both badger-derived infection from within the population and externally-derived, trickle-type, infection, such as could occur from other species or environmental sources, using a spatial stochastic simulation model. The presence of external sources of infection can increase mean prevalence and reduce the threshold group size for disease persistence. Above the threshold equilibrium group size of 6-8 individuals predicted by the model for bTB persistence in badgers based on internal infection alone, external sources of infection have relatively little impact on the persistence or level of disease. However, within a critical range of group sizes just below this threshold level, external infection becomes much more important in determining disease dynamics. Within this critical range, external infection increases the ratio of intra- to inter-group infections due to the greater probability of external infections entering fully-susceptible groups. The effect is to enable bTB persistence and increase bTB prevalence in badger populations which would not be able to maintain bTB based on internal infection alone. External sources of bTB infection can contribute to the persistence of bTB in badger populations. In high-density badger populations, internal badger-derived infections occur at a sufficient rate that the additional effect of external sources in exacerbating disease is minimal. However, in lower-density populations, external sources of infection are much more important in enhancing bTB prevalence and persistence. In such circumstances, it is particularly important that control strategies to reduce bTB in badgers include efforts to minimise such external sources of infection.
2012-01-01
Background The persistence of bovine TB (bTB) in various countries throughout the world is enhanced by the existence of wildlife hosts for the infection. In Britain and Ireland, the principal wildlife host for bTB is the badger (Meles meles). The objective of our study was to examine the dynamics of bTB in badgers in relation to both badger-derived infection from within the population and externally-derived, trickle-type, infection, such as could occur from other species or environmental sources, using a spatial stochastic simulation model. Results The presence of external sources of infection can increase mean prevalence and reduce the threshold group size for disease persistence. Above the threshold equilibrium group size of 6–8 individuals predicted by the model for bTB persistence in badgers based on internal infection alone, external sources of infection have relatively little impact on the persistence or level of disease. However, within a critical range of group sizes just below this threshold level, external infection becomes much more important in determining disease dynamics. Within this critical range, external infection increases the ratio of intra- to inter-group infections due to the greater probability of external infections entering fully-susceptible groups. The effect is to enable bTB persistence and increase bTB prevalence in badger populations which would not be able to maintain bTB based on internal infection alone. Conclusions External sources of bTB infection can contribute to the persistence of bTB in badger populations. In high-density badger populations, internal badger-derived infections occur at a sufficient rate that the additional effect of external sources in exacerbating disease is minimal. However, in lower-density populations, external sources of infection are much more important in enhancing bTB prevalence and persistence. In such circumstances, it is particularly important that control strategies to reduce bTB in badgers include efforts to minimise such external sources of infection. PMID:22738118
Abdel Hakim, Mahmoud A; Abdalla, Ahmed A; Saad, Ismail R; ElSheemy, Mohammed S; El Feel, Ahmed S; Salem, Hosni K; Abdel Hakim, Amr M
2016-06-01
To prospectively compare the use of external ureteric stents with internal JJ stenting of the uretero-ileal anastomosis in patients undergoing laparoscopic radical cystectomy (LRC) with a Y-shaped ileal orthotopic neobladder (ON). The study included 69 patients undergoing LRC with ON. Patients were grouped according to the type of uretero-ileal stents used. An external ureteric stent was used in Group A (33 patients) and a JJ stent was used in Group B (36). We prospectively compared the duration of hospital stay, the incidence of short- and intermediate-term complications in the two study groups. The mean (SD) follow-up periods were 29.18 (3.94) and 28.19 (3.37) months for patients in Groups A and B, respectively. Perioperative patient characteristics were comparable in the two study groups. The use of JJ stenting was associated with a shorter hospital stay compared with external stenting, at a mean (SD) of 14.63 (3.74) and 6.8 (3.03) days in Groups A and B, respectively (P < 0.001). The incidence of urinary leakage was comparable in the two study groups, at 6.1% in Group A vs 8.3% in Group B (P = 1.0). Strictures of the uretero-ileal anastomosis occurred in two patients (6%) in Group A and confirmed by intravenous urography. All strictures were treated with antegrade JJ fixation. JJ stents could be used as an effective alternative to external ureteric stents to support the uretero-ileal anastomosis. JJ stenting is associated with a shorter hospital stay and similar complication rates compared with external stenting in patients undergoing LRC with ON.
Long, Qilai; Zhang, Jian; Xu, Zhibing; Zhu, Yanjun; Liu, Li; Wang, Hang; Guo, Jianming; Wang, Guomin
2016-04-01
We evaluate the efficacy and safety of external physical vibration lithecbole in improving the clearance rates of lower pole renal stones after shock wave lithotripsy. A total of 71 patients with lower pole renal stones (6 to 20 mm) were prospectively randomized into 2 groups. In the treatment group 34 patients were treated with external physical vibration lithecbole after shock wave lithotripsy. In the control group 37 patients underwent shock wave lithotripsy only. External physical vibration lithecbole was performed without anesthesia by the same team using the Friend-I External Physical Vibration Lithecbole (Fu Jian Da Medical Instrument Co., Ltd, Zhengzhou, China). The stone-free rate, stone expulsion rate, stone expulsion time and incidence of complications were monitored. External physical vibration lithecbole was successful in assisting the discharge of stone fragments. The stone-free status was 76.5% in the treatment group and 48.6% in the control group (p=0.008). Stone expulsion rates at day 1, week 1 and week 3 were 76.5% (26), 94.1% (32) and 94.1% (32) in the treatment group vs 43.2% (16), 73.0% (27) and 89.2% (33) in the control group, respectively. Mean stone fragment expulsion time was 11.2 minutes in the treatment group and 9.17 hours in the control group (p=0.016). There was no significant difference in complications between the 2 groups (p >0.05). External physical vibration lithecbole was efficacious in assisting the discharge of lower pole renal stone fragments and can be used as an adjunctive method of minimally invasive stone treatment. However, additional investigations are needed to confirm the efficacy. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Yahav, R
2007-07-01
This study examined the relationship between children's and adolescents' external (aggression or delinquent behaviour) and internal (depression and anxiety, somatic complaints or regressive behaviour) symptoms and their perceptions of parenting behaviour. Participants were 159 children (83 boys and 76 girls) aged 10-17 years and were categorized into five groups. The two experimental groups included clearly defined externalizing (n=35) and internalizing (n=46) children. Two sibling groups and one non-sibling group served as controls. The five groups were compared for subjective perceptions of maternal and paternal rejection, favouritism and overprotection. No effects of age or gender were found. The results revealed that compared with non-symptomatic children from different families and with non-symptomatic siblings, both internalizing and externalizing children obtained higher scores on the variables examined. Externalizing children obtained the highest scores, while internalizing children obtained intermediate scores. The sibling comparison data revealed a gap between the perceptions of symptomatic children and their siblings: symptomatic children reported negative parenting practices towards both themselves and their siblings, whereas the opposite was true of sibling reports. The reports suggest that while both internalizing and externalizing symptoms are associated with negative perceptions of the parent-child interaction, this may be particularly the case among externalizing children. The importance of perceptions of reality, as opposed to objective circumstances, is discussed in the context of treatment.
Ganguly, Anasua; Kaza, Hrishikesh; Kapoor, Aditya; Sheth, Jenil; Ali, Mohammad Hasnat; Tripathy, Devjyoti; Rath, Suryasnata
The purpose of this study was to compare the characteristics of the ostium after external dacryocystorhinostomy and nonendoscopic endonasal dacryocystorhinostomy (NEN-DCR). This cross-sectional study included patients who underwent a successful external dacryocystorhinostomy or NEN-DCR and had ≥1 month follow up. Pictures of the ostium were captured with a nasal endoscope (4 mm, 30°) after inserting a lacrimal probe premarked at 2 mm. Image analyses were performed using Image J and Contour softwares. Of the 113 patients included, external dacryocystorhinostomy group had 53 patients and NEN-DCR group had 60 patients. The mean age of patients in the NEN-DCR group (38 years) was significantly (p < 0.05) lower than the external dacryocystorhinostomy group (50 years). There was no statistically significant difference (2 sample t test, p > 0.05) in mean follow up (6 vs. 4 months), maximum diameter of ostium (8 vs. 7 mm), perpendicular drawn to it (4 vs. 4 mm), area of ostium (43 vs. 36 mm), and the minimum distance between common internal punctum and edge of the ostium (1 vs. 1 mm) between the external and NEN-DCR groups. Image processing softwares offer simple and objective method to measure the ostium. While ostia are comparable in size, their relative position differs with posteriorly placed ostia in external compared with inferior in NEN-DCR.
NASA Astrophysics Data System (ADS)
Faghihi, F.; Khalili, S.
2013-08-01
This article involves two aims for BNCT. First case includes a beam shaping assembly estimation for a D-T neutron source to find epi-thermal neutrons which are the goal in the BNCT. Second issue is the percent depth dose calculation in the adult Snyder head phantom. Monte-Carlo simulations and verification of a suggested beam shaping assembly (including internal neutron multiplier, moderator, filter, external neutron multiplier, collimator, and reflector dimensions) for thermalizing a D-T neutron source as well as increasing neutron flux are carried out and our results are given herein. Finally, we have simulated its corresponding doses for treatment planning of a deeply-seated tumor.
Transient loads analysis for space flight applications
NASA Technical Reports Server (NTRS)
Thampi, S. K.; Vidyasagar, N. S.; Ganesan, N.
1992-01-01
A significant part of the flight readiness verification process involves transient analysis of the coupled Shuttle-payload system to determine the low frequency transient loads. This paper describes a methodology for transient loads analysis and its implementation for the Spacelab Life Sciences Mission. The analysis is carried out using two major software tools - NASTRAN and an external FORTRAN code called EZTRAN. This approach is adopted to overcome some of the limitations of NASTRAN's standard transient analysis capabilities. The method uses Data Recovery Matrices (DRM) to improve computational efficiency. The mode acceleration method is fully implemented in the DRM formulation to recover accurate displacements, stresses, and forces. The advantages of the method are demonstrated through a numerical example.
Quantitative verification of ab initio self-consistent laser theory.
Ge, Li; Tandy, Robert J; Stone, A D; Türeci, Hakan E
2008-10-13
We generalize and test the recent "ab initio" self-consistent (AISC) time-independent semiclassical laser theory. This self-consistent formalism generates all the stationary lasing properties in the multimode regime (frequencies, thresholds, internal and external fields, output power and emission pattern) from simple inputs: the dielectric function of the passive cavity, the atomic transition frequency, and the transverse relaxation time of the lasing transition.We find that the theory gives excellent quantitative agreement with full time-dependent simulations of the Maxwell-Bloch equations after it has been generalized to drop the slowly-varying envelope approximation. The theory is infinite order in the non-linear hole-burning interaction; the widely used third order approximation is shown to fail badly.
NASA Technical Reports Server (NTRS)
Werrett, Stephen; Seivold, Alfred L.
1990-01-01
A detailed nodal computer model was developed to thermally represent the hardware, and sensitivity studies were performed to evaluate design parameters and orbital environmental effects of an instrument cooling system for IR detectors. Thermal-vacuum testing showed excellent performance of the system and a correspondence with math model predictions to within 3 K. Results show cold stage temperature sensitivity to cold patch backload, outer stage external surface emittance degradation, and cold stage emittance degradation, respectively. The increase in backload on the cold patch over the mission lifetime is anticipated to be less than 3.0 watts, which translates to less than a 3-degree increase in detector temperatures.
Effect of cyclic loading and retightening on reverse torque value in external and internal implants.
Cho, Woong-Rae; Huh, Yoon-Hyuk; Park, Chan-Jin; Cho, Lee-Ra
2015-08-01
The aim of this study was to evaluate the effect of cyclic loading and screw retightening on reverse torque value (RTV) in external and internal type implants. Cement-retained abutments were connected with 30 Ncm torque to external and internal type implants. Experimental groups were classified according to implant connection type and retightening/loading protocol. In groups with no retightening, RTV was evaluated after cyclic loading for 100,000 cycles. In groups with retightening, RTV was measured after 3, 10, 100 cycles as well as every 20,000 cycles until 100,000 cycles of loading. Every group showed decreased RTV after cyclic loading. Before and after cyclic loading, external type implants had significantly higher RTVs than internal type implants. In external type implants, retightening did not affect the decrease in RTV. In contrast, retightening 5 times and retightening after 10 cycles of dynamic loading was effective for maintaining RTV in internal type implants. Retightening of screws is more effective in internal type implants than external type implants. Retightening of screws is recommended in the early stage of functional loading.
Position verification systems for an automated highway system.
DOT National Transportation Integrated Search
2015-03-01
Automated vehicles promote road safety, fuel efficiency, and reduced travel time by decreasing traffic : congestion and driver workload. In a vehicle platoon (grouping vehicles to increase road capacity by : managing distance between vehicles using e...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-17
...: VA Form Letter 21-914 is use to verify whether Filipino veterans of the Special Philippine Scouts, Commonwealth Army of the Philippines, organized guerilla groups receiving service-connected compensation...
Radiometric, geometric, and image quality assessment of ALOS AVNIR-2 and PRISM sensors
Saunier, S.; Goryl, P.; Chander, G.; Santer, R.; Bouvet, M.; Collet, B.; Mambimba, A.; Kocaman, Aksakal S.
2010-01-01
The Advanced Land Observing Satellite (ALOS) was launched on January 24, 2006, by a Japan Aerospace Exploration Agency (JAXA) H-IIA launcher. It carries three remote-sensing sensors: 1) the Advanced Visible and Near-Infrared Radiometer type 2 (AVNIR-2); 2) the Panchromatic Remote-Sensing Instrument for Stereo Mapping (PRISM); and 3) the Phased-Array type L-band Synthetic Aperture Radar (PALSAR). Within the framework of ALOS Data European Node, as part of the European Space Agency (ESA), the European Space Research Institute worked alongside JAXA to provide contributions to the ALOS commissioning phase plan. This paper summarizes the strategy that was adopted by ESA to define and implement a data verification plan for missions operated by external agencies; these missions are classified by the ESA as third-party missions. The ESA was supported in the design and execution of this plan by GAEL Consultant. The verification of ALOS optical data from PRISM and AVNIR-2 sensors was initiated 4 months after satellite launch, and a team of principal investigators assembled to provide technical expertise. This paper includes a description of the verification plan and summarizes the methodologies that were used for radiometric, geometric, and image quality assessment. The successful completion of the commissioning phase has led to the sensors being declared fit for operations. The consolidated measurements indicate that the radiometric calibration of the AVNIR-2 sensor is stable and agrees with the Landsat-7 Enhanced Thematic Mapper Plus and the Envisat MEdium-Resolution Imaging Spectrometer calibration. The geometrical accuracy of PRISM and AVNIR-2 products improved significantly and remains under control. The PRISM modulation transfer function is monitored for improved characterization.
45 CFR 147.136 - Internal claims and appeals and external review processes.
Code of Federal Regulations, 2010 CFR
2010-10-01
... RELATING TO HEALTH CARE ACCESS HEALTH INSURANCE REFORM REQUIREMENTS FOR THE GROUP AND INDIVIDUAL HEALTH... external review processes for group health plans and health insurance issuers that are not grandfathered...) In general. A group health plan and a health insurance issuer offering group or individual health...
45 CFR 147.136 - Internal claims and appeals and external review processes.
Code of Federal Regulations, 2013 CFR
2013-10-01
... RELATING TO HEALTH CARE ACCESS HEALTH INSURANCE REFORM REQUIREMENTS FOR THE GROUP AND INDIVIDUAL HEALTH... external review processes for group health plans and health insurance issuers that are not grandfathered...) In general. A group health plan and a health insurance issuer offering group or individual health...
45 CFR 147.136 - Internal claims and appeals and external review processes.
Code of Federal Regulations, 2012 CFR
2012-10-01
... RELATING TO HEALTH CARE ACCESS HEALTH INSURANCE REFORM REQUIREMENTS FOR THE GROUP AND INDIVIDUAL HEALTH... external review processes for group health plans and health insurance issuers that are not grandfathered...) In general. A group health plan and a health insurance issuer offering group or individual health...
45 CFR 147.136 - Internal claims and appeals and external review processes.
Code of Federal Regulations, 2014 CFR
2014-10-01
... RELATING TO HEALTH CARE ACCESS HEALTH INSURANCE REFORM REQUIREMENTS FOR THE GROUP AND INDIVIDUAL HEALTH... external review processes for group health plans and health insurance issuers that are not grandfathered...) In general. A group health plan and a health insurance issuer offering group or individual health...
45 CFR 147.136 - Internal claims and appeals and external review processes.
Code of Federal Regulations, 2011 CFR
2011-10-01
... RELATING TO HEALTH CARE ACCESS HEALTH INSURANCE REFORM REQUIREMENTS FOR THE GROUP AND INDIVIDUAL HEALTH... external review processes for group health plans and health insurance issuers that are not grandfathered...) In general. A group health plan and a health insurance issuer offering group or individual health...
76 FR 51147 - Medicaid Program; Eligibility Changes Under the Affordable Care Act of 2010
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-17
... elect to phase-in'' coverage for this optional group ``based on the categorical group (including non... (Sec. 435.603(f)(2)) (2) Household Composition for Non-Filers (Sec. 435.603(f)(3)) (3) Retention of... (Sec. 435.952) 5. Verification of Other Non-Financial Information (Sec. 435.956) H. Periodic...
The Purefecta™ was tested for removal of bacteria and viruses at NSF International's Drinking Water Treatment Systems Laboratory. Kinetico submitted 10 units for testing, which were split into two groups of five. One group received 25 days of conditioning prior to challeng...
Wu, Chih-Da; Chen, Yu-Cheng; Pan, Wen-Chi; Zeng, Yu-Ting; Chen, Mu-Jean; Guo, Yue Leon; Lung, Shih-Chun Candice
2017-05-01
This study utilized a long-term satellite-based vegetation index, and considered culture-specific emission sources (temples and Chinese restaurants) with Land-use Regression (LUR) modelling to estimate the spatial-temporal variability of PM 2.5 using data from Taipei metropolis, which exhibits typical Asian city characteristics. Annual average PM 2.5 concentrations from 2006 to 2012 of 17 air quality monitoring stations established by Environmental Protection Administration of Taiwan were used for model development. PM 2.5 measurements from 2013 were used for external data verification. Monthly Normalized Difference Vegetation Index (NDVI) images coupled with buffer analysis were used to assess the spatial-temporal variations of greenness surrounding the monitoring sites. The distribution of temples and Chinese restaurants were included to represent the emission contributions from incense and joss money burning, and gas cooking, respectively. Spearman correlation coefficient and stepwise regression were used for LUR model development, and 10-fold cross-validation and external data verification were applied to verify the model reliability. The results showed a strongly negative correlation (r: -0.71 to -0.77) between NDVI and PM 2.5 while temples (r: 0.52 to 0.66) and Chinese restaurants (r: 0.31 to 0.44) were positively correlated to PM 2.5 concentrations. With the adjusted model R 2 of 0.89, a cross-validated adj-R 2 of 0.90, and external validated R 2 of 0.83, the high explanatory power of the resultant model was confirmed. Moreover, the averaged NDVI within a 1750 m circular buffer (p < 0.01), the number of Chinese restaurants within a 1750 m buffer (p < 0.01), and the number of temples within a 750 m buffer (p = 0.06) were selected as important predictors during the stepwise selection procedures. According to the partial R 2 , NDVI explained 66% of PM 2.5 variation and was the dominant variable in the developed model. We suggest future studies consider these three factors when establishing LUR models for estimating PM 2.5 in other Asian cities. Copyright © 2017 Elsevier Ltd. All rights reserved.
Application of Video Image Correlation Techniques to the Space Shuttle External Tank Foam Materials
NASA Technical Reports Server (NTRS)
Hilburger, Mark W.; Nemeth, Michael P.
2005-01-01
Results that illustrate the use of a video-image-correlation-based displacement and strain measurement system to assess the effects of material nonuniformities on the behavior of the sprayed-on foam insulation (SOFI) used for the thermal protection system on the Space Shuttle External Tank are presented. Standard structural verification specimens for the SOFI material with and without cracks and subjected to mechanical or thermal loading conditions were tested. Measured full-field displacements and strains are presented for selected loading conditions to illustrate the behavior of the foam and the viability of the measurement technology. The results indicate that significant strain localization can occur in the foam because of material nonuniformities. In particular, elongated cells in the foam can interact with other geometric or material discontinuities in the foam and develop large-magnitude localized strain concentrations that likely initiate failures. Furthermore, some of the results suggest that continuum mechanics and linear elastic fracture mechanics might not adequately represent the physical behavior of the foam, and failure predictions based on homogeneous linear material models are likely to be inadequate.
Application of Video Image Correlation Techniques to the Space Shuttle External Tank Foam Materials
NASA Technical Reports Server (NTRS)
Hilburger, Mark W.; Nemeth, Michael P.
2006-01-01
Results that illustrate the use of a video-image-correlation-based displacement and strain measurement system to assess the effects of material nonuniformities on the behavior of the sprayed-on foam insulation (SOFI) used for the thermal protection system on the Space Shuttle External Tank are presented. Standard structural verification specimens for the SOFI material with and without cracks and subjected to mechanical or thermal loading conditions were tested. Measured full-field displacements and strains are presented for selected loading conditions to illustrate the behavior of the foam and the viability of the measurement technology. The results indicate that significant strain localization can occur in the foam because of material nonuniformities. In particular, elongated cells in the foam can interact with other geometric or material discontinuities in the foam and develop large-magnitude localized strain concentrations that likely initiate failures. Furthermore, some of the results suggest that continuum mechanics and linear elastic fracture mechanics might not adequately represent the physical behavior of the foam, and failure predictions based on homogeneous linear material models are likely to be inadequate.
What is Quantum Mechanics? A Minimal Formulation
NASA Astrophysics Data System (ADS)
Friedberg, R.; Hohenberg, P. C.
2018-03-01
This paper presents a minimal formulation of nonrelativistic quantum mechanics, by which is meant a formulation which describes the theory in a succinct, self-contained, clear, unambiguous and of course correct manner. The bulk of the presentation is the so-called "microscopic theory", applicable to any closed system S of arbitrary size N, using concepts referring to S alone, without resort to external apparatus or external agents. An example of a similar minimal microscopic theory is the standard formulation of classical mechanics, which serves as the template for a minimal quantum theory. The only substantive assumption required is the replacement of the classical Euclidean phase space by Hilbert space in the quantum case, with the attendant all-important phenomenon of quantum incompatibility. Two fundamental theorems of Hilbert space, the Kochen-Specker-Bell theorem and Gleason's theorem, then lead inevitably to the well-known Born probability rule. For both classical and quantum mechanics, questions of physical implementation and experimental verification of the predictions of the theories are the domain of the macroscopic theory, which is argued to be a special case or application of the more general microscopic theory.
NASA Technical Reports Server (NTRS)
Stuckey, James M.
1996-01-01
The selection and quantification of four foams using a more environmentally friendly HCFC-141b blowing agent replacing foams that used the CFC-11 blowing agent for the external tank (ET) LWT has been addressed along with problems and solutions that were encountered during verification. The effort on two lower density spray foams for the ET SLWT are presented, but predicted weight savings were not encouraging. Suggestions for possible problem solving are included along with a new approach for selecting foams for qualification as back-up foams for the foams used on the ET LWT. We investigated three resins for use as thermally sprayed coatings for corrosion prevention on metal. The best coating was obtained with a thermoplastic polyimide resin. This coating has a good chance of meeting ET requirements. Possible third generation blowing agents have been shown usable in polyurethane spray and pour foams, and solubility in isocyannate foam components are acceptable. We considered aerogels as insulation materials on space vehicles, and suggested a liner for a liquid oxygen (LOX) composite tank.
Muñoz, H; Guerra, S; Perez-Vaquero, P; Valero Martinez, C; Aizpuru, F; Lopez-Picado, A
2014-02-01
Breech presentation occurs in up to 3% of pregnancies at term and may be an indication for caesarean delivery. External cephalic version can be effective in repositioning the fetus in a cephalic presentation, but may be painful for the mother. Our aim was to assess the efficacy of remifentanil versus placebo for pain relief during external cephalic version. A randomized, double-blind, controlled trial that included women at 36-41 weeks of gestation with non-cephalic presentations was performed. Women were randomized to receive either a remifentanil infusion at 0.1 μg/kg/min and demand boluses of 0.1 μg/kg, or saline placebo. The primary outcome was the numerical rating pain score (0-10) after external cephalic version. Sixty women were recruited, 29 in the control group and 31 in the remifentanil group. There were significant differences in pain scores at the end of the procedure (control 6.5 ± 2.4 vs. remifentanil 4.7 ± 2.5, P = 0.005) but not 10 min later (P = 0.054). The overall success rate for external cephalic version was 49% with no significant differences between groups (remifentanil group 54.8% vs. control group 41.3%, P = 0.358). In the remifentanil group, there was one case of nausea and vomiting, one of drowsiness and three cases of fetal bradycardia. In the control group, there were three cases of nausea and vomiting, one of dizziness and nine cases of fetal bradycardia. Intravenous remifentanil with bolus doses on demand during external cephalic version achieved a reduction in pain and increased maternal satisfaction. There were no additional adverse effects, and no difference in the success rate of external cephalic version or the incidence of fetal bradycardia. Copyright © 2013 Elsevier Ltd. All rights reserved.
Union rate of tibiotalocalcaneal nails with internal or external bone stimulation.
De Vries, J George; Berlet, Gregory C; Hyer, Christopher F
2012-11-01
The use of bone growth stimulation has been reported in the application of hindfoot and ankle arthrodesis. Most studies have been retrospective case series with few patients. The authors present a comparative analysis of patients undergoing tibiotalocalcaneal (TTC) arthrodesis via a retrograde intramedullary arthrodesis nail to evaluate the influence of internal versus external bone stimulation in this population. One hundred fifty-four patients were treated with retrograde intramedullary nailing. A comprehensive chart and radiographic review was performed from a database of patients who underwent TTC fusion with or without bone stimulation. Ninety-one patients with retrograde TTC nailing were treated with direct current internal bone stimulation at the time of the index procedure (internal group) and 63 were treated with combined magnetic field external bone stimulation (external group). The primary end point was fusion with potential variables evaluated for influence on fusion rates. Demographically the cohorts were similar groups in age and comorbidities. Surgical and outcome data were examined, and there were few statistically significant differences between the two groups. There was no statistically significant difference in rate of union (52.7% and 57.1%, p = .63) or rate of complications between the internal and external groups. Overall, the success rate for achieving a stable, functional limb for the groups was 81.3% (74/91 patients) and 82.5% (52/63 patients) in the internal and external groups, respectively (p = .62). The authors demonstrated there were no statistically significant differences between the union and complication rate when comparing these types of internal and external bone stimulation in this patient population. Consideration of these results may help guide physicians when considering bone stimulation as an adjunct to TTC fusions with a retrograde intramedullary nail.
Li, Wen; Chan, Angus C W; Lau, James Y W; Lee, Danny W H; Ng, Enders K W; Sung, Joseph J Y; Chung, S C Sydney
2004-02-01
The role of Kupffer cells in obstructive jaundice (OJ) has not been fully understood. The aims of the present study were to measure superoxide and nitric oxide (NO) production by Kupffer cells in experimental OJ in rats and to investigate the response to internal and external biliary drainage. Eighty male Sprague-Dawley rats were assigned to four groups: sham operation, OJ, and internal and external biliary drainage. Kupffer cells were isolated on day 7 in the sham operation and OJ group, and on day 7 after drainage procedures. Cells were cultured with or without lipopolysaccharide (LPS). Superoxide production was quantified in cultured Kupffer cells at 2 h and 48 h, respectively, after cell isolation using the superoxide dismutase inhibitable ferricytochrome c reduction method. Nitrite production in cell culture supernatants was measured 48 h later using Greiss reagents. Without LPS stimulation, Kupffer cells produced comparable superoxide and nitrite in each group (P > 0.05). With LPS stimulation, Kupffer cells in the OJ group produced significantly higher superoxide anions than the other groups (P = 0.006). Nitrite production was significantly increased in the OJ group and external biliary drainage group compared to rats in the sham operation and internal drainage groups (P < 0.01). Kupffer cells from rats with OJ produce great amounts of endotoxin-mediated oxidants. Both internal and external biliary drainage can decrease the elevated superoxide production. Internal drainage is superior to external drainage for reversing the distortional capacity of NO production by Kupffer cells.
Midface distraction osteogenesis: internal vs. external devices.
Meling, T R; Høgevold, H-E; Due-Tønnessen, B J; Skjelbred, P
2011-02-01
This study compares internal and external distraction devices in the treatment of midface retrusion. 20 patients were treated with midface distraction (12 Crouzon, 4 Apert, 4 others); 12 with internal distraction (MID device), 8 with external distraction (Red or Blue device). The two groups were compared regarding operation time, peroperative blood loss and complications. The groups were comparable regarding patient age, sex, weight and diagnosis. In the MID-group, 7 of 12 patients (58%) underwent Le Fort III, 5 underwent 12 monobloc (32%). In the Blue device group, three of eight patients underwent Le Fort II (38%), three of eight underwent Le Fort III (38%), and two of eight underwent monobloc (25%). Operation time was shorter in the Blue device (mean 298 min) than in the MID group (mean 354 min). Peroperative blood loss and complication rates were similar. The internal distraction device is the 'gold standard' for treating midface retrusion. The use of an external distraction device in midface distraction osteogenesis is associated with a shorter operation time; peroperative blood loss and complications were similar. An external device affords better 3-dimensional control during the distraction process, so external distraction is preferable in patients who will tolerate this treatment. Copyright © 2010 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
EPA'S ENVIRONMENTAL TECHNOLOGY VERIFICATION PROGRAM
The U.S. Environmental Protection Agency (EPA) has evaluated technologies to determine their effectiveness in monitoring, preventing, controlling, and cleaning up pollution. Since the early 1990s, however, numerous government and private groups have determined that the lack of a...
29 CFR 2590.715-2719 - Internal claims and appeals and external review processes.
Code of Federal Regulations, 2012 CFR
2012-07-01
... SECURITY ADMINISTRATION, DEPARTMENT OF LABOR GROUP HEALTH PLANS RULES AND REGULATIONS FOR GROUP HEALTH... and appeals and external review processes for group health plans and health insurance issuers that are..., 2010. (b) Internal claims and appeals process—(1) In general. A group health plan and a health...
29 CFR 2590.715-2719 - Internal claims and appeals and external review processes.
Code of Federal Regulations, 2014 CFR
2014-07-01
... SECURITY ADMINISTRATION, DEPARTMENT OF LABOR GROUP HEALTH PLANS RULES AND REGULATIONS FOR GROUP HEALTH... and appeals and external review processes for group health plans and health insurance issuers that are..., 2010. (b) Internal claims and appeals process—(1) In general. A group health plan and a health...
29 CFR 2590.715-2719 - Internal claims and appeals and external review processes.
Code of Federal Regulations, 2013 CFR
2013-07-01
... SECURITY ADMINISTRATION, DEPARTMENT OF LABOR GROUP HEALTH PLANS RULES AND REGULATIONS FOR GROUP HEALTH... and appeals and external review processes for group health plans and health insurance issuers that are..., 2010. (b) Internal claims and appeals process—(1) In general. A group health plan and a health...
Human Factors in the Design of the Crew Exploration Vehicle (CEV)
NASA Technical Reports Server (NTRS)
Whitmore, Mihriban; Byrne, Vicky; Holden, Kritina
2007-01-01
NASA s Space Exploration vision for humans to venture to the moon and beyond provides interesting human factors opportunities and challenges. The Human Engineering group at NASA has been involved in the initial phases of development of the Crew Exploration Vehicle (CEV), Orion. Getting involved at the ground level, Human Factors engineers are beginning to influence design; this involvement is expected to continue throughout the development lifecycle. The information presented here describes what has been done to date, what is currently going on, and what is expected in the future. During Phase 1, prior to the contract award to Lockheed Martin, the Human Engineering group was involved in generating requirements, conducting preliminary task analyses based on interviews with subject matter experts in all vehicle systems areas, and developing preliminary concepts of operations based on the task analysis results. In addition, some early evaluations to look at CEV net habitable volume were also conducted. The program is currently in Phase 2, which is broken down into design cycles, including System Readiness Review, Preliminary Design Review, and Critical Design Review. Currently, there are ongoing Human Engineering Technical Interchange Meetings being held with both NASA and Lockheed Martin in order to establish processes, desired products, and schedules. Multiple design trades and quick-look evaluations (e.g. display device layout and external window size) are also in progress. Future Human Engineering activities include requirement verification assessments and crew/stakeholder evaluations of increasing fidelity. During actual flights of the CEV, the Human Engineering group is expected to be involved in in-situ testing and lessons learned reporting, in order to benefit human space flight beyond the initial CEV program.
Surface contamination analysis technology team overview
NASA Astrophysics Data System (ADS)
Burns, H. Dewitt, Jr.
1996-11-01
The surface contamination analysis technology (SCAT) team was originated as a working roup of NASA civil service, Space Shuttle contractor, and university groups. Participating members of the SCAT Team have included personnel from NASA Marshall Space Flight Center's Materials and Processes Laboratory and Langley Research Center's Instrument Development Group; contractors-Thiokol Corporation's Inspection Technology Group, AC Engineering support contractor, Aerojet, SAIC, and Lockheed MArtin/Oak Ridge Y-12 support contractor and Shuttle External Tank prime contractor; and the University of Alabama in Huntsville's Center for Robotics and Automation. The goal of the SCAT team as originally defined was to develop and integrate a multi-purpose inspection head for robotic application to in-process inspection of contamination sensitive surfaces. One area of interest was replacement of ozone depleting solvents currently used for surface cleanliness verification. The team approach brought together the appropriate personnel to determine what surface inspection techniques were applicable to multi-program surface cleanliness inspection. Major substrates of interest were chosen to simulate space shuttle critical bonding surface or surfaces sensitive to contamination such as fuel system component surfaces. Inspection techniques evaluated include optically stimulated electron emission or photoelectron emission; Fourier transform infrared spectroscopy; near infrared fiber optic spectroscopy; and, ultraviolet fluorescence. Current plans are to demonstrate an integrated system in MSFC's Productivity Enhancement Complex within five years from initiation of this effort in 1992. Instrumentation specifications and designs developed under this effort include a portable diffuse reflectance FTIR system built by Surface Optics Corporation and a third generation optically stimulated electron emission system built by LaRC. This paper will discuss the evaluation of the various techniques on a number of substrate materials contaminated with hydrocarbons, silicones, and fluorocarbons. Discussion will also include standards development for instrument calibration and testing.
NASA Astrophysics Data System (ADS)
Jasiczak, Józef; Girus, Krzysztof
2017-10-01
The issue of usability and durability of large-panel building constructed several decades ago is a subject of an in-depth analysis of many domestic and foreign investments. When considering the durability of specific large-panel system, one should consider, among others, the process of making external walls. The long-term and direct impact of weather conditions on the external layer of curtain walls is significant for the durability of large-panel buildings. For the needs of the presented paper, in 2016, the survey of cracks and a series of other tests of large-panel façade, residential building constructed in 1986, in Poland, in the PLP process system - Rataje was executed. Several hundred large-size, triple-layer curtain-wall slab with a 6-cm, concrete exterior cladding layer anchored using pins and hangers with the load-bearing layer, a 9-cm insulation layer made of mineral wool, and a 21-cm structural layer were surveyed. Significant deviations in thicknesses of particular wall layers were proven. Other significant damages and defects of external layers were found. At the second stage, many tests, both nondestructive and destructive, were conducted. They involved determining mechanical properties of an external layer. The concrete thickness was measured using with a type N Schmidt sclerometer and core samples were taken from this layer in order to mark concrete’s compressive strength. The range of carbonation (by phenolphthalein method) and the actual location and condition of reinforcement were estimated using a ferromagnetic device to determine the condition of the external layer. The diagnosis conducted in such a manner was the verification of necessary repair of the walls and their thermal efficiency improvement while ensuring safe conditions of their operation and modern functional and utility requirements. It should be also emphasized that the method of diagnosing the external walls presented in this paper may be popularized when evaluating such facilities both in Poland and other countries of the Central Europe (Germany, Czechia, Slovakia, Lithuania, Bulgaria, and Ukraine).
NASA Astrophysics Data System (ADS)
Williams, Krystaufeux D.
The work discussed in this dissertation is an experimental validation of a body of research that was created to model stress corrosion cracking phenomenon for 304 stainless steels in boiling water reactors. This coupled environment fracture model (CEFM) incorporates the natural laws of the conservation of charge and the differential aeration hypothesis to predict the amount of stress corrosion crack growth as a function of many external environmental variables, including potential, stress intensity, solution conductivity, oxidizer concentrations, and various other environmental parameters. Out of this approach came the concept of the coupling current; a local corrosion current that flows from within cracks, crevices, pits, etc... of a metal or alloy to the external surface. Because of the deterministic approach taken in the mentioned research, the coupling current analysis and CEFM model can be applied to the specific problem of SCC in aluminum alloy 5083 (the alloy of interest for this dissertation that is highly sought after today because of its corrosion resistance and high strength to weight ratio). This dissertation research is specifically devoted to the experimental verification of the coupling current, which results from a coupling between the crack's internal and external environments, by spatially resolving them using the scanning vibrating probe (SVP) as a tool. Hence, through the use of a unique fracture mechanics setup, simultaneous mechanical and local electrochemical data may be obtained, in situ..
Diao, K; Farmani, R; Fu, G; Astaraie-Imani, M; Ward, S; Butler, D
2014-01-01
Large water distribution systems (WDSs) are networks with both topological and behavioural complexity. Thereby, it is usually difficult to identify the key features of the properties of the system, and subsequently all the critical components within the system for a given purpose of design or control. One way is, however, to more explicitly visualize the network structure and interactions between components by dividing a WDS into a number of clusters (subsystems). Accordingly, this paper introduces a clustering strategy that decomposes WDSs into clusters with stronger internal connections than external connections. The detected cluster layout is very similar to the community structure of the served urban area. As WDSs may expand along with urban development in a community-by-community manner, the correspondingly formed distribution clusters may reveal some crucial configurations of WDSs. For verification, the method is applied to identify all the critical links during firefighting for the vulnerability analysis of a real-world WDS. Moreover, both the most critical pipes and clusters are addressed, given the consequences of pipe failure. Compared with the enumeration method, the method used in this study identifies the same group of the most critical components, and provides similar criticality prioritizations of them in a more computationally efficient time.
Langley, Audra K; Lewin, Adam B; Bergman, R Lindsey; Lee, Joyce C; Piacentini, John
2010-08-01
The present study examines the influence of diagnostic comorbidity on the demographic, psychiatric, and functional status of youth with a primary diagnosis of obsessive compulsive disorder (OCD). Two hundred and fifteen children (ages 5-17) referred to a university-based OCD specialty clinic were compared based on DSM-IV diagnostic profile: OCD without comorbid anxiety or externalizing disorder, OCD plus anxiety disorder, and OCD plus externalizing disorder. No age or gender differences were found across groups. Higher OCD severity was found for the OCD + ANX group, while the OCD + EXT group reported greater functional impairment than the other two groups. Lower family cohesion was reported by the OCD + EXT group compared to the OCD group and the OCD + ANX group reported higher family conflict compared to the OCD + EXT group. The OCD + ANX group had significantly lower rates of tic disorders while rates of depressive disorders did not differ among the three groups. The presence of comorbid anxiety and externalizing psychopathology are associated with greater symptom severity and functional and family impairment and underscores the importance of a better understanding of the relationship of OCD characteristics and associated disorders. Results and clinical implications are further discussed.
Beck, Eric N; Intzandt, Brittany N; Almeida, Quincy J
2018-01-01
It may be possible to use attention-based exercise to decrease demands associated with walking in Parkinson's disease (PD), and thus improve dual task walking ability. For example, an external focus of attention (focusing on the effect of an action on the environment) may recruit automatic control processes degenerated in PD, whereas an internal focus (limb movement) may recruit conscious (nonautomatic) control processes. Thus, we aimed to investigate how externally and internally focused exercise influences dual task walking and symptom severity in PD. Forty-seven participants with PD were randomized to either an Externally (n = 24) or Internally (n = 23) focused group and completed 33 one-hour attention-based exercise sessions over 11 weeks. In addition, 16 participants were part of a control group. Before, after, and 8 weeks following the program (pre/post/washout), gait patterns were measured during single and dual task walking (digit-monitoring task, ie, walking while counting numbers announced by an audio-track), and symptom severity (UPDRS-III) was assessed ON and OFF dopamine replacement. Pairwise comparisons (95% confidence intervals [CIs]) and repeated-measures analyses of variance were conducted. Pre to post: Dual task step time decreased in the external group (Δ = 0.02 seconds, CI 0.01-0.04). Dual task step length (Δ = 2.3 cm, CI 0.86-3.75) and velocity (Δ = 4.5 cm/s, CI 0.59-8.48) decreased (became worse) in the internal group. UPDRS-III scores (ON and OFF) decreased (improved) in only the External group. Pre to washout: Dual task step time ( P = .005) and percentage in double support ( P = .014) significantly decreased (improved) in both exercise groups, although only the internal group increased error on the secondary counting task (ie, more errors monitoring numbers). UPDRS-III scores in both exercise groups significantly decreased ( P = .001). Since dual task walking improvements were found immediately, and 8 weeks after the cessation of an externally focused exercise program, we conclude that externally focused exercise may improve on functioning of automatic control networks in PD. Internally focused exercise hindered dual tasking ability. Overall, externally focused exercise led to greater rehabilitation benefits in dual tasking and motor symptoms compared with internally focused exercise.
Grelewska-Nowotko, Katarzyna; Żurawska-Zajfert, Magdalena; Żmijewska, Ewelina; Sowa, Sławomir
2018-05-01
In recent years, digital polymerase chain reaction (dPCR), a new molecular biology technique, has been gaining in popularity. Among many other applications, this technique can also be used for the detection and quantification of genetically modified organisms (GMOs) in food and feed. It might replace the currently widely used real-time PCR method (qPCR), by overcoming problems related to the PCR inhibition and the requirement of certified reference materials to be used as a calibrant. In theory, validated qPCR methods can be easily transferred to the dPCR platform. However, optimization of the PCR conditions might be necessary. In this study, we report the transfer of two validated qPCR methods for quantification of maize DAS1507 and NK603 events to the droplet dPCR (ddPCR) platform. After some optimization, both methods have been verified according to the guidance of the European Network of GMO Laboratories (ENGL) on analytical method verification (ENGL working group on "Method Verification." (2011) Verification of Analytical Methods for GMO Testing When Implementing Interlaboratory Validated Methods). Digital PCR methods performed equally or better than the qPCR methods. Optimized ddPCR methods confirm their suitability for GMO determination in food and feed.
Formal verification of a microcoded VIPER microprocessor using HOL
NASA Technical Reports Server (NTRS)
Levitt, Karl; Arora, Tejkumar; Leung, Tony; Kalvala, Sara; Schubert, E. Thomas; Windley, Philip; Heckman, Mark; Cohen, Gerald C.
1993-01-01
The Royal Signals and Radar Establishment (RSRE) and members of the Hardware Verification Group at Cambridge University conducted a joint effort to prove the correspondence between the electronic block model and the top level specification of Viper. Unfortunately, the proof became too complex and unmanageable within the given time and funding constraints, and is thus incomplete as of the date of this report. This report describes an independent attempt to use the HOL (Cambridge Higher Order Logic) mechanical verifier to verify Viper. Deriving from recent results in hardware verification research at UC Davis, the approach has been to redesign the electronic block model to make it microcoded and to structure the proof in a series of decreasingly abstract interpreter levels, the lowest being the electronic block level. The highest level is the RSRE Viper instruction set. Owing to the new approach and some results on the proof of generic interpreters as applied to simple microprocessors, this attempt required an effort approximately an order of magnitude less than the previous one.
Profile of mortality from external causes among Seventh-day Adventists and the general populations.
Velten, Ana Paula Costa; Cade, Nágela Valadão; Silva, Gulnar Azevedo E; Oliveira, Elizabete Regina Araújo de
2017-07-01
This paper aimed to compare the profile of mortality from external causes among Seventh-day Adventists and the general population of Espírito Santo from 2003 to 2009. A search of Adventists was performed in the nominal database of the Mortality Information System containing data on Adventists provided by the administrative offices of the institution. Deaths from external causes occurred during the study period were then divided into two groups: Adventists and the general population. Adventists had lower proportional mortality from external causes (10%) than the general population (19%), and males were the main reason for this difference. In both groups, deaths prevailed in the 20-29 years age group. Deaths from accidental causes were most significant among Adventists (68.08%), while deaths from intentional causes related to assault and self-inflicted injuries were more significant in the general population (53.67% of all deaths). The standardized mortality ratio for external causes was 41.3, thus, being Adventist reduced mortality by 58.7%. It is believed that the benefit of Adventists observed for mortality from external causes is related to this group's abstinence from alcohol consumption.
Effect of cyclic loading and retightening on reverse torque value in external and internal implants
Cho, Woong-Rae; Huh, Yoon-Hyuk; Park, Chan-Jin
2015-01-01
PURPOSE The aim of this study was to evaluate the effect of cyclic loading and screw retightening on reverse torque value (RTV) in external and internal type implants. MATERIALS AND METHODS Cement-retained abutments were connected with 30 Ncm torque to external and internal type implants. Experimental groups were classified according to implant connection type and retightening/loading protocol. In groups with no retightening, RTV was evaluated after cyclic loading for 100,000 cycles. In groups with retightening, RTV was measured after 3, 10, 100 cycles as well as every 20,000 cycles until 100,000 cycles of loading. RESULTS Every group showed decreased RTV after cyclic loading. Before and after cyclic loading, external type implants had significantly higher RTVs than internal type implants. In external type implants, retightening did not affect the decrease in RTV. In contrast, retightening 5 times and retightening after 10 cycles of dynamic loading was effective for maintaining RTV in internal type implants. CONCLUSION Retightening of screws is more effective in internal type implants than external type implants. Retightening of screws is recommended in the early stage of functional loading. PMID:26330975
NASA Astrophysics Data System (ADS)
Debes, John H.
2013-05-01
As part of the calibration of the second lifetime position on the Cosmic Origins Spectrograph (COS) far-ultraviolet (FUV) detectors, observations of the external target, G191-B2B, were obtained with the G130M, G160M, and G140L gratings in combi- nation with the Bright Object Aperture. The observations were designed to verify the performance of these spectroscopic modes by reproducing similar observations taken during the SM4 Servicing Mission Observatory Verification (SMOV) of COS. These observations allowed for a detailed determination of the spatial location and profile of the spectra from the three gratings, as well as a determination of the spectral resolution of the G130M grating prior to and after the lifetime move. In general, the negligi- ble differences which exist between the two lifetime positions can be attributed to slight differences in the optical path. In particular, the spectral resolution appears to be slightly improved. The stability of the absolute and relative flux calibration was investigated for G130M as well using STIS echelle data of G191-B2B. We determine that the COS ab- solute flux calibration with the BOA is accurate to 10%, and flux calibrated data are reproducible at the 1-2% level since SMOV.
Development of a Response Surface Thermal Model for Orion Mated to the International Space Station
NASA Technical Reports Server (NTRS)
Miller, Stephen W.; Meier, Eric J.
2010-01-01
A study was performed to determine if a Design of Experiments (DOE)/Response Surface Methodology could be applied to on-orbit thermal analysis and produce a set of Response Surface Equations (RSE) that accurately predict vehicle temperatures. The study used an integrated thermal model of the International Space Station and the Orion Outer mold line model. Five separate factors were identified for study: yaw, pitch, roll, beta angle, and the environmental parameters. Twenty external Orion temperatures were selected as the responses. A DOE case matrix of 110 runs was developed. The data from these cases were analyzed to produce an RSE for each of the temperature responses. The initial agreement between the engineering data and the RSE predictions was encouraging, although many RSEs had large uncertainties on their predictions. Fourteen verification cases were developed to test the predictive powers of the RSEs. The verification showed mixed results with some RSE predicting temperatures matching the engineering data within the uncertainty bands, while others had very large errors. While this study to not irrefutably prove that the DOE/RSM approach can be applied to on-orbit thermal analysis, it does demonstrate that technique has the potential to predict temperatures. Additional work is needed to better identify the cases needed to produce the RSEs
30 CFR 250.913 - When must I resubmit Platform Verification Program plans?
Code of Federal Regulations, 2010 CFR
2010-07-01
... Structures Platform Verification Program § 250.913 When must I resubmit Platform Verification Program plans? (a) You must resubmit any design verification, fabrication verification, or installation verification... 30 Mineral Resources 2 2010-07-01 2010-07-01 false When must I resubmit Platform Verification...
The Sears Kenmore Ultrafilter 500 RO system was tested for removal of bacteria and viruses at NSF International's Drinking Water Treatment Systems Laboratory. EcoWater Systems submitted ten units for testing, which were split into two groups of five. One group received 25 days ...
The Watts Premier Ultra 5 system was tested for removal of bacteria and viruses at NSF International's Laboratory. Watts Premier submitted ten units, which were split into two groups of five. One group received 25 days of conditioning prior to challenge testing, while the secon...
Transistor step stress testing program for JANTX2N2484
NASA Technical Reports Server (NTRS)
1979-01-01
The effect of power/temperature step stress when applied to the transistor JANTX2N2484, manufactured by Raytheon and Teledyne was evaluated. Forty-eight samples from each manufacturer were divided equally (16 per group) into three groups and submitted to the processes outlined. In addition, two control sample units were maintained for verification of the electrical parametric testing.
Gulini, Martina; Prados, Concepción; Pérez, Amparo; Romero, David; Feliz, Darwin; Gómez Carrera, Luis; Cabanillas, Juan José; Barbero, Javier; Alvarez-Sala, Rodolfo
2012-01-01
Analysis of psychological variables, quality of life, depression and anxiety, subjective perception of compliance, level of satisfaction with the electronic device, and objective verification) in order to study the therapeutic adherence, in non-cystic fibrosis bronchiectasis (NCFB) colonized by Pseudomonas aeruginosa. A cross-sectional descriptive study was conducted on 22 NCFB stable patients colonised by Pseudomonas aeruginosa (two groups of 11 subjects: GROUP 1, Pari-LC plus nebuliser device, and GROUP 2, with the I- neb device), both containing sodium colistemethate. Different variables, were obtained, such as, self-perceived health (St George questionnaire), state of mind (HADS scale), and subjective perception of therapeutic compliance and objective verification by using the device software. There were no significant differences in questionnaire results. The therapeutic support in GROUP 2, could be proved objectively (up to 60%) using specific software, and the excellent tolerability using a specific questionnaire created for the study. These types of aerosol devices demonstrate a high level of therapeutic support, that can be measured objectively and is different from what the patients subjectively indicates. Copyright © 2011 Elsevier España, S.L. All rights reserved.
Ma, Chuang; Deng, Qiang; Pu, Hongwei; Cheng, Xinchun; Kan, Yuhua; Yang, Jing; Yusufu, Aihemaitijiang; Cao, Li
2016-01-01
The purpose of this study was to compare the functional outcomes, psychological impact, and complication rates associated with external fixation and volar or dorsal plating in relation to the functional parameters following treatment of intra-articular fractures of the distal radius (IFDR) in patients older than 65 years. We hypothesized that using volar or dorsal plating would improve functional outcomes, but that it would be associated with more complications and equivalent functional outcomes when compared with the external fixation group. A total of 123 consecutive patients suffering from IFDR were recruited into the study. The patients were measured for clinical, radiological, and psychosocial functioning outcomes and were followed up after 1 week and 3, 6 and 12 months. After 3 months, the plating group had better pronation (P=0.001), supination, (P=0.047) and extension (P=0.043) scores. These differences were somewhat attenuated by 6 months and disappeared at 1 year. The plating group had a greater occurrence of wound infection (P=0.043), tendonitis, (P=0.024) and additional surgery compared with the external fixation group. The only TNO-AZL Adult Quality of Life scores in the plating group that were lower than those in the external fixation group were in the “gross motor” category (walking upstairs, bending over, walking 500 yards; P=0.023). Internal fixation was more advantageous than external fixation in the early rehabilitation period; after 1 year the outcomes were similar. The plating group showed significantly higher levels of wound infection and tendonitis and had a greater need for additional surgeries. PMID:27408765
Mudhol, Rekha R; Zingade, N D; Mudhol, R S; Harugop, Anil S; Das, Amal T
2013-08-01
The aim of the study is to compare the subjective (relief of symptoms) and objective (endoscopic visualization of ostium patency at the time of syringing) outcomes at the end of two procedures-Endonasal DCR versus External DCR with Mitomycin C and to assess the role of Mitomycin C in maintaining patency of nasolacrimal drainage system. Prospective randomized comparative study was performed. Thirty-five patients were enrolled in each endoscopic and external dacryocystorhinostomy groups with Mitomycin C (MMC) application. The 37 eyes underwent endonasal DCR (28 unilateral primary eyes + 1 bilateral primary eyes + 5 unilateral revision eyes + 1 bilateral revision eye) while 35 eyes underwent external DCR (34 unilateral primary eyes + 1 unilateral revision eye). Mitomycin C 0.2 mg/ml was applied intra-operatively for 5 min to the ostium site at the end of endonasal or external DCR procedure. Objective assessment by syringing at the end of 1 year in the endonasal group showed 35 eyes (94%) were patent, 1 (3%) was partially blocked and 1(3%) was completely blocked; while in external group all 35 eyes (100%) were patent. Endoscopic visualization of the ostium at the time of syringing showed only one eye (3%) in the endonasal group was blocked while all the other eyes in both groups were patent. Both groups had a mean follow-up of 6-36 months. No complications were associated with use of Mitomycin C. In conclusion, intra-operative use of Mitomycin C in both endoscopic DCR and external DCR is safe and effective in increasing the success rate.
Schmidt, Megan R; Lisco, Claire G; Parrott, Dominic J; Tharp, Andra T
2016-03-01
The present study sought to examine the interactive effects of an external locus of control and interaction in a negative peer group climate on men's perpetration of physical aggression and infliction of injury toward their female intimate partners. Participants were 206 heterosexual males recruited from the metro-Atlanta community who completed self-report measures of external locus of control, involvement in a negative peer group climate, and physical aggression and infliction of injury against intimate partners during the past 12 months. Negative peer group climate was conceptualized as a peer group that displays behavior which may instigate aggressive norms, attitudes, and behaviors. Results indicated that men with an external locus of control were more likely to perpetrate physical aggression toward and inflict injury on their intimate partners if they reported high, but not low, involvement in a negative peer group climate. These results extend current research suggesting external locus of control as a risk factor for intimate partner aggression by highlighting the impact of negative peer groups. Implications and future intervention research are discussed. © The Author(s) 2014.
Interactive effects of the affect quality and directional focus of mental imagery on pain analgesia.
Alden, A L; Dale, J A; DeGood, D E
2001-06-01
College students (25 men and 25 women) were randomly assigned (within sex) to each of the 4 factorial groups, based on manipulation of affect quality (positive vs. negative) and directional focus (internal vs. external) of mental imagery, and to a control group receiving no manipulation. Both imagery variables had a significant impact on pain tolerance and ratings during a cold-pressor test with positive affect and external imagery producing greater analgesia than their counterpart conditions. Positive affect imagery combined with external imagery resulted in the lowest reported pain amongst the groups. However, self-reported mood descriptors did not consistently parallel the pain tolerance and rating data. Likewise, although heart rate and skin potential responses increased during the cold pressor for the group as a whole, the only significant difference amongst the experimental groups was the relatively higher skin potential reactivity of the positive affect-external imagery group--possibly reflecting greater task engagement for this group. Seemingly, imagery in this situation operates primarily via cognitive, rather than via physiological mediators of the pain experience.
Hruban, L; Janků, P; Jordánová, K; Gerychová, R; Huser, M; Ventruba, P; Roztočil, A
2017-01-01
Evaluation of success rate and the safety of external cephalic version after 36 weeks of gestation. Retrospective analysis. Department of Obstetrics and Gynecology, Masaryk University, University Hospital Brno. A retrospective analysis of external cephalic version attempts performed on a group of 638 singleton breech pregnancies after 36 weeks gestation in the years 2003-2016 at the Department of Gynecology and Obstetrics, Masaryk University, Brno. The effectiveness, number and type of complications, mode of delivery and perinatal result were observed. The effectiveness of external cephalic version from breech to head presentation was 47.8% (305 cases). After a successful external cephalic version 238 patients (78.0%) gave birth vaginally. After unsuccessful cephalic version 130 patients (39.0%) gave birth vaginally. The number of serious complications did not exceed 0,9% and did not affect perinatal outcomes. External cephalic version-related emergency cesarean deliveries occurred in 6 cases (2 placental abruption, 4 abnormal cardiotocography). The fetal outcome was good in all these cases. The death of the fetus in connection with the external version has not occurred in our file. Spontaneous discharge of amniotic fluid within 24 hours after procedure occurred in 5 cases (0.8%). The spontaneous onset of labor within 24 hours of procedure occurred in 5 cases (0.8%). The pH value of a. umbilicalis < 7.00 occurred in 2 cases in the group with a successful external version and in the group with unsuccessful external version in 9 cases. The Apgar score in the 5th minute < 5 was both in the successful and unsuccessful group in 1 case. The external cephalic version of the fetus in the case of breech presentation after the 36th week of pregnancy is an effective and safe alternative for women who have a fear of the vaginal breech delivery. Performing the external cephalic version can reduce the rate of elective caesarean sections due to breech presentation at term.
Generic Verification Protocol for Verification of Online Turbidimeters
This protocol provides generic procedures for implementing a verification test for the performance of online turbidimeters. The verification tests described in this document will be conducted under the Environmental Technology Verification (ETV) Program. Verification tests will...
Nifedipine as a uterine relaxant for external cephalic version: a randomized controlled trial.
Kok, Marjolein; Bais, Joke M; van Lith, Jan M; Papatsonis, Dimitri M; Kleiverda, Gunilla; Hanny, Dahrs; Doornbos, Johannes P; Mol, Ben W; van der Post, Joris A
2008-08-01
To estimate the effectiveness of nifedipine as a uterine relaxant during external cephalic version to correct breech presentation. In this randomized, double-blind, placebo-controlled trial, women with a singleton fetus in breech presentation and a gestational age of 36 weeks or more were eligible for enrollment. Participating women received two doses of either nifedipine 10 mg or placebo, 30 and 15 minutes before the external cephalic version attempt. The primary outcome was a cephalic-presenting fetus immediately after the procedure. Secondary outcome measures were cephalic presentation at delivery, mode of delivery, and adverse events. A sample size of 292 was calculated to provide 80% power to detect a 17% improvement of the external cephalic version success rate, assuming a placebo group rate of 40% and alpha of .05. Outcome data for 310 of 320 randomly assigned participants revealed no significant difference in external cephalic version success rates between treatment (42%) and control group (37%) (relative risk 1.1, 95%; 95% confidence interval 0.85-1.5). The cesarean delivery rate was 51% in the treatment group and 46% in the control group (relative risk 1.1, 95% confidence interval 0.88-1.4). Nifedipine did not significantly improve the success of external cephalic version. Future use of nifedipine to improve the outcome of external cephalic version should be limited to large clinical trials.
Whelan, Daniel B; Kletke, Stephanie N; Schemitsch, Geoffrey; Chahal, Jaskarndip
2016-02-01
The recurrence rate after primary anterior shoulder dislocation is high, especially in young, active individuals. Recent studies have suggested external rotation immobilization as a method to reduce the rate of recurrent shoulder dislocation in comparison to traditional sling immobilization. To assess and summarize evidence from randomized controlled trials on the effect of internal rotation versus external rotation immobilization on the rate of recurrence after primary anterior shoulder dislocation. Meta-analysis. PubMed, MEDLINE, EMBASE, the Cochrane Central Register of Controlled Trials, and abstracts from recent proceedings were searched for eligible studies. Two reviewers selected studies for inclusion, assessed methodological quality, and extracted data. Six randomized controlled trials (632 patients) were included in this review. Demographic and prognostic variables measured at baseline were similar in the pooled groups. The average age was 30.1 years in the pooled external rotation group and 30.3 years in the pooled internal rotation group. Two studies found that external rotation immobilization reduced the rate of recurrence after initial anterior shoulder dislocation compared with conventional internal rotation immobilization, whereas 4 studies failed to find a significant difference between the 2 groups. This meta-analysis suggested no overall significant difference in the rate of recurrence among patients treated with internal rotation versus external rotation immobilization (risk ratio, 0.69; 95% CI, 0.42-1.14; P = .15). There was no significant difference in the rate of compliance between internal and external rotation immobilization (P = .43). The Western Ontario Shoulder Instability Index scores were pooled across 3 studies, and there was no significant difference between the 2 groups (P = .54). Immobilization in external rotation is not significantly more effective in reducing the recurrence rate after primary anterior shoulder dislocation than immobilization in internal rotation. Additionally, this review suggests that there is minimal difference in patients' perceptions of their health-related quality of life after immobilization in internal versus external rotation. © 2015 The Author(s).
Zhang, Haiying; Jiao, Ling; Cui, Songye; Wang, Liang; Tan, Jian; Zhang, Guizhi; He, Yajing; Ruan, Shuzhou; Fan, Saijun; Zhang, Wenyi
2014-01-01
Radiation safety is an integral part of targeted radionuclide therapy. The aim of this work was to study the external dose rate and retained body activity as functions of time in differentiated thyroid carcinoma patients receiving 131I therapy. Seventy patients were stratified into two groups: the ablation group (A) and the follow-up group (FU). The patients’ external dose rate was measured, and simultaneously, their retained body radiation activity was monitored at various time points. The equations of the external dose rate and the retained body activity, described as a function of hours post administration, were fitted. Additionally, the release time for patients was calculated. The reduction in activity in the group receiving a second or subsequent treatment was more rapid than the group receiving only the initial treatment. Most important, an expeditious method was established to indirectly evaluate the retained body activity of patients by measuring the external dose rate with a portable radiation survey meter. By this method, the calculated external dose rate limits are 19.2, 8.85, 5.08 and 2.32 μSv·h−1 at 1, 1.5, 2 and 3 m, respectively, according to a patient’s released threshold level of retained body activity <400 MBq. This study is beneficial for radiation safety decision-making. PMID:25337944
Yaman, Ayşe; Mesman, Judi; van Ijzendoorn, Marinus H; Bakermans-Kranenburg, Marian J
2010-04-01
Examining family stress and parenting efficacy in relation to child externalizing problems in immigrant families. In this study, we compared the levels of family stress, parenting efficacy, and toddler externalizing behaviors in Dutch (n = 175) and second-generation Turkish immigrant families (n = 175) living in the Netherlands. In addition, the influence of Turkish mothers' acculturation on toddler externalizing behaviors and its association with perceived stress and efficacy were examined. Turkish mothers reported higher levels of daily stress and marital discord than Dutch mothers, but did not differ in perceptions of parenting efficacy and children's externalizing behaviors. The associations between child and family variables were similar in the Dutch and the Turkish groups, as more family stress was related to more externalizing behaviors in toddlers. Low parenting efficacy was the most important predictor of child externalizing behaviors in both groups. Acculturation of Turkish mothers was not associated with family and child variables, and did not moderate the association between family variables and child externalizing behaviors. However, emotional connectedness to the Turkish culture was related to less daily stress and fewer marital problems. The results support the no-group differences hypothesis and also imply that cultural maintenance may be adaptive for parental well-being.
Sakata, Sachi; Naruse, Takashi; Taguchi, Atsuko; Murashima, Sachiyo
2014-01-01
Mothers who experience difficulty in childrearing are becoming increasingly more prevalent in Japan. This study described and classified mothers' childrearing difficulty in terms of their children's behavioral characteristics and related factors. Self-administered questionnaires were distributed to 818 mothers at their children's 3-year-old health checkup in eight suburban cities in Japan. The questionnaire consisted of items assessing the mother's experience of difficulty in childrearing for the child undergoing the checkup. The subjects were classified into four groups according to their children's behavioral characteristics: "low needs," "internalizing behavior," "externalizing behavior," and "comorbid internalizing-externalizing behavior." Multiple regression analysis was performed to examine the relationships between mothers' difficulty in childrearing and related factors. A total of 775 respondents were divided as follows: 332 mothers had children with low needs, 104 had those with internalizing behavior, 230 had those with externalizing behavior, and 109 had those with comorbid internalizing-externalizing behavior. Mothers in the low needs group showed less childrearing difficulty than did mothers in the other groups. Childrearing difficulty increased by group in the following order: internalizing, externalizing, and comorbid internalizing-externalizing. In all four groups, mothers with low self-efficacy and less appraisal support from their family encountered greater childrearing difficulty. In the low needs group, experiencing childrearing difficulty with another child was related experiencing childrearing difficulty with the child undergoing the checkup. In the internalizing behavior group, mothers who had experienced greater difficulty in childrearing were more likely to be housewives and of younger age, and were more likely to have had boys as the child undergoing the checkup. In the externalizing behavior group, mothers with more difficulty in childrearing were more likely to be younger and less healthy, have less appraisal support from their friends, and live in apartments. In the comorbid internalizing-externalizing group, if the mothers were housewives, they were more likely to have difficulty in caring for their other children, receive less appraisal support from their friends, and experience more difficulty in childrearing. The results showed that mothers' difficulty in childrearing and the factors related to this difficulty differed according to their children's behavioral characteristics. Public health nurses could provide more effective care and support to mothers by considering children's behavioral characteristics.
5 CFR 890.401 - Temporary extension of coverage and conversion.
Code of Federal Regulations, 2010 CFR
2010-01-01
..., is entitled to a 31-day extension of coverage for self alone or self and family, as the case may be... or her group coverage and must be accompanied by verification of termination of the enrollment; e.g...
Lansford, Jennifer E.; Criss, Michael M.; Pettit, Gregory S.; Dodge, Kenneth A.; Bates, John E.
2009-01-01
Quality of peer relationships and perceived peer antisocial behavior were examined as moderators of the link between negative parenting and externalizing behavior problems in school from middle childhood to early adolescence. Data on negative parenting (i.e., unilateral parental decision making, low supervision and awareness, and harsh discipline) were collected from 362 parents in the summer preceding the adolescents’ entry into Grade 6. Adolescent reports of positive peer relationships and peer antisocial behavior were assessed in the winter of Grade 7. The outcome measure was teacher report of adolescent externalizing behavior in the spring of Grade 7, controlling for externalizing behavior in Grade 5. High levels of friendship quality and peer group affiliation attenuated the association between unilateral parental decision making and adolescent externalizing behavior in school; this was particularly true when adolescents associated with peers perceived to be low in antisocial behavior. In addition, having low-quality peer relationships and having peers perceived to be highly antisocial further amplified the association between unilateral parental decision making and adolescent externalizing behavior problems. Finally, high levels of friend and peer group antisocial behavior exacerbated the predictiveness of harsh discipline for adolescents’ externalizing behavior. PMID:20209019
On the torque and wear behavior of selected thin film MOS2 lubricated gimbal bearings
NASA Technical Reports Server (NTRS)
Bohner, John J.; Conley, Peter L.
1988-01-01
During the thermal vacuum test phase of the GOES 7 spacecraft, the primary scan mirror system exhibited unacceptably high drive friction. The observed friction was found to correlate with small misalignments in the mirror structure and unavoidable loads induced by the vehicle spin. An intensive effort to understand and document the performance of the scan mirror bearing system under these loads is described. This effort involved calculation of the bearing loads and expected friction torque, comparison of the computed values to test data, and verification of the lubrication system performance and limitations under external loads. The study culminated in a successful system launch in February of 1987. The system has operated as predicted since that time.
CLIPS: A tool for the development and delivery of expert systems
NASA Technical Reports Server (NTRS)
Riley, Gary
1991-01-01
The C Language Integrated Production System (CLIPS) is a forward chaining rule-based language developed by the Software Technology Branch at the Johnson Space Center. CLIPS provides a complete environment for the construction of rule-based expert systems. CLIPS was designed specifically to provide high probability, low cost, and easy integration with external systems. Other key features of CLIPS include a powerful rule syntax, an interactive development environment, high performance, extensibility, a verification/validation tool, extensive documentation, and source code availability. The current release of CLIPS, version 4.3, is being used by over 2,500 users throughout the public and private community including: all NASA sites and branches of the military, numerous Federal bureaus, government contractors, 140 universities, and many companies.
Verification Games: Crowd-Sourced Formal Verification
2016-03-01
VERIFICATION GAMES : CROWD-SOURCED FORMAL VERIFICATION UNIVERSITY OF WASHINGTON MARCH 2016 FINAL TECHNICAL REPORT...DATES COVERED (From - To) JUN 2012 – SEP 2015 4. TITLE AND SUBTITLE VERIFICATION GAMES : CROWD-SOURCED FORMAL VERIFICATION 5a. CONTRACT NUMBER FA8750...clarification memorandum dated 16 Jan 09. 13. SUPPLEMENTARY NOTES 14. ABSTRACT Over the more than three years of the project Verification Games : Crowd-sourced
Scheuermann, Taneisha S; Richter, Kimber P; Rigotti, Nancy A; Cummins, Sharon E; Harrington, Kathleen F; Sherman, Scott E; Zhu, Shu-Hong; Tindle, Hilary A; Preacher, Kristopher J
2017-12-01
To estimate the prevalence and predictors of failed biochemical verification of self-reported abstinence among participants enrolled in trials of hospital-initiated smoking cessation interventions. Comparison of characteristics between participants who verified and those who failed to verify self-reported abstinence. Multi-site randomized clinical trials conducted between 2010 and 2014 in hospitals throughout the United States. Recently hospitalized smokers who reported tobacco abstinence 6 months post-randomization and provided a saliva sample for verification purposes (n = 822). Outcomes were salivary cotinine-verified smoking abstinence at 10 and 15 ng/ml cut-points. Predictors and correlates included participant demographics and tobacco use; hospital diagnoses and treatment; and study characteristics collected via surveys and electronic medical records. Usable samples were returned by 69.8% of the 1178 eligible trial participants who reported 7-day point prevalence abstinence. The proportion of participants verified as quit was 57.8% [95% confidence interval (CI) = 54.4, 61.2; 10 ng/ml cut-off] or 60.6% (95% CI = 57.2, 63.9; 15 ng/ml). Factors associated independently with verification at 10 ng/ml were education beyond high school education [odds ratio (OR) = 1.51; 95% CI = 1.07, 2.11], continuous abstinence since hospitalization (OR = 2.82; 95% CI = 2.02, 3.94), mailed versus in-person sample (OR = 3.20; 95% CI = 1.96, 5.21) and race. African American participants were less likely to verify abstinence than white participants (OR = 0.64; 95% CI = 0.44, 0.93). Findings were similar for verification at 15 ng/ml. Verification rates did not differ by treatment group. In the United States, high rates (40%) of recently hospitalized smokers enrolled in smoking cessation trials fail biochemical verification of their self-reported abstinence. © 2017 Society for the Study of Addiction.
Bajwa, Ali S.; Rammappa, Manju; Lee, Ling; Nanda, Rajesh
2015-01-01
Introduction: Distal radius fracture (DRF) is a common injury and various treatment modalities including open reduction and internal fixation (ORIF) with volar locking plate are available. More recently, a non-invasive external fixator has been used. Aims: To prospectively compare the use of a non-invasive external fixator with early dynamisation for DRF against ORIF with volar locking plate control group. Methods: Consecutive patients with closed DRF were included in a prospective case-controlled study. Patients were assigned to non-invasive external fixator or ORIF. Minimum follow-up was two years. Follow-up was at weeks 2, 4, 6, 8, 12, 26 and at one and two-year post-operatively. The outcome measures included demographic details, injury mechanism, AO fracture type, risk factors, body mass index (BMI), ulnar styloid fracture and dorsal comminution, radiographs, grip strength and DASH score. Results: Consecutive 50 patients were treated either with non-invasive external fixator (25/50) or with ORIF (25/50) and the mean age of the two groups was 53 years (SD 17.1) and 49 years (SD 19.5), respectively. Demographics were matched in two groups. In the non-invasive external fixator group, there were 10 AO Type-A, 5 Type-B and 10 Type-C fractures. The ORIF group included 8 Type-A, 6 Type-B and 11 Type-C fractures. The mean DASH score at three-months and one-year post-injury in non-invasive fixator group was 12.2 (SD 3.1) and 3.5 (SD 0.7), respectively, significantly greater than those of ORIF group 14.5 (SD 5.6) and 11.2 (SD 4.4), respectively (p < 0.05). Conclusion: DRF treated with non-invasive external fixator can give functional results superior to ORIF at three-months and the trend is maintained at one and two-year post-operatively. PMID:27163089
RAS - Target Identification - Informatics
The RAS Informatics lab group develops tools to track and analyze “big data” from the RAS Initiative, as well as analyzes data from external projects. By integrating internal and external data, this group helps improve understanding of RAS-driven cancers.
Rozenman, Michelle; Peris, Tara S; Gonzalez, Araceli; Piacentini, John
2016-02-01
This study compared youth ages 5-17 years with a primary diagnosis of trichotillomania (TTM, n = 30) to those with primary OCD (n = 30) and tic disorder (n = 29) on demographic characteristics, internalizing, and externalizing symptoms. Findings suggest that youth with primary TTM score more comparably to youth with tics than those with OCD on internalizing and externalizing symptom measures. Compared to the OCD group, youth in the TTM group reported lower levels of anxiety and depression. Parents of youth in the TTM group also reported fewer internalizing, externalizing, attention, and thought problems than those in the OCD group. Youth with TTM did not significantly differ from those with primary Tic disorders on any measure. Findings suggest that pediatric TTM may be more similar to pediatric tic disorders than pediatric OCD on anxiety, depression, and global internalizing and externalizing problems.
Van Voorhees, Benjamin W; Hsiung, Robert C; Marko-Holguin, Monika; Houston, Thomas K; Fogel, Joshua; Lee, Royce; Ford, Daniel E
2013-03-12
Depressive disorders and symptoms affect more than one-third of primary care patients, many of whom do not receive or do not complete treatment. Internet-based social support from peers could sustain depression treatment engagement and adherence. We do not know whether primary care patients will accept referral to such websites nor do we know which methods of referral would be most effective. We conducted a randomized clinical trial to determine whether (1) a simple generic referral card (control), (2) a patient-oriented brochure that provided examples of online postings and experience (internal motivation), or (3) a physician letter of recommendation (external motivation) would generate the greatest participation in a primary care Internet depression treatment support portal focused around an Internet support group (ISG). We used 3 offline methods to identify potential participants who had not used an ISG in the past 6 months. Eligibility was determined in part by a brief structured psychiatric interview based on the Patient Health Questionnaire-9 (PHQ-9). After consent and enrollment, participants were randomly assigned to 1 of 3 groups (control, internal motivation, or external motivation). We constructed a portal to connect primary care patients to both fact-based information and an established ISG (Psycho-Babble). The ISG allowed participants to view messages and then decide if they actually wished to register there. Participation in the portal and the ISG was assessed via automated activity tracking. Fifty participants were assigned to the 3 groups: a motivation-neutral control group (n=18), an internal motivation group (n=19), and an external motivation group (n=13). Of these participants, 31 (62%) visited the portal; 27 (54%) visited the ISG itself. The internal motivation group showed significantly greater participation than the control group on several measures. The external motivation group spent significantly less time logged onto the portal than the control group. The internal motivation group showed significantly greater participation than the external motivation group on several measures. Referral of primary care patients with depressive disorders and symptoms to an ISG is feasible even if they have never previously used one. This may best be accomplished by enhancing their internal motivation.
Strand, Leif Aage; Martinsen, Jan Ivar; Fadum, Elin Anita; Borud, Einar Kristian
2017-08-01
To investigate external-cause mortality among 21 609 Norwegian male military peacekeepers deployed to Lebanon during 1978-1998. The cohort was followed from the 1st day of deployment through 2013, and mortality during deployment and post discharge was assessed using SMRs calculated from national rates in Norway. Poisson regression was used to see the effect of high-conflict versus low-conflict exposure. For the total cohort, external-cause mortality was within expected values during deployment (SMR=0.80) and post discharge (SMR=1.05). In the low-conflict exposure group, a lower mortality from all external causes (SMR=0.77), transport accidents (SMR=0.55) and accidental poisoning (SMR=0.53) was seen. The high-conflict exposure group showed an elevated mortality from all external causes (SMR=1.20), transport accidents (SMR=1.51) and suicide (SMR=1.30), but these risks were elevated only during the first 5 years after discharge. This group also showed elevated mortality from all external causes (rate ratio, RR=1.49), and for transport accidents (RR=3.30) when compared with the low-conflict exposure group. Overall external-cause mortality among our peacekeepers was equal to national rates during deployment and post discharge. High-conflict exposure was associated with elevated mortality from all external causes, transport accidents and suicide during the first 5 years after discharge from service. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
ERIC Educational Resources Information Center
Edney, Julian J.; Bell, Paul A.
1984-01-01
Conducted two studies in which subjects (N=216) faced the dilemma of how to harvest resources from a shared pool when faced with external catastrophies and given opportunities to steal. Results showed that tying the individual's outcome to the rest of the group is good for the group. (LLL)
ERIC Educational Resources Information Center
Banit, Olga
2017-01-01
The author performs analysis of external and internal factors that influence organization of the system of Polish managers' professional development. These factors can be united into two groups. We will attribute the factors formed under the influence of external factors to the first group, to the second--the internal ones. So, due to the dynamic…
Zeno, Helios A; Buitrago, Renan L; Sternberger, Sidney S; Patt, Marisa E; Tovar, Nick; Coelho, Paulo; Kurtz, Kenneth S; Tuminelli, Frank J
2016-04-01
To compare the removal of torque values of machined implant abutment connections (internal and external) with and without soft tissue entrapment using an in vitro model. Thirty external- and 30 internal-connection implants were embedded in urethane dimethacrylate. Porcine tissue was prepared and measured to thicknesses of 0.5 and 1.0 mm. Six groups (n = 10) were studied: External- and internal-connection implants with no tissue (control), 0.5, and 1.0 mm of tissue were entrapped at the implant/abutment interface. Abutments were inserted to 20 Ncm for all six groups. Insertion torque values were recorded using a digital torque gauge. All groups were then immersed in 1 M NaOH for 48 hours to dissolve tissue. Subsequent reverse torque measurements were recorded. Mean and standard deviation were determined for each group, and one-way ANOVA and Bonferroni test were used for statistical analysis. All 60 specimens achieved a 20-Ncm insertion torque, despite tissue entrapment. Reverse torque measurements for external connection displayed a statistically significant difference (p < 0.05) between all groups with mean reverse torque values for the control (13.71 ± 1.4 Ncm), 0.5 mm (7.83 ± 2.4 Ncm), and 1.0 mm tissue entrapment (2.29 ± 1.4 Ncm) groups. Some statistically significant differences (p < 0.05) were found between internal-connection groups. In all specimens, tissue did not completely dissolve after 48 hours. External-connection implants were significantly affected by tissue entrapment; the thicker the tissue, the lower the reverse torque values noted. Internal-connection implants were less affected by tissue entrapment. © 2015 by the American College of Prosthodontists.
3-Rooted Maxillary First Premolars: An Ex Vivo Study of External and Internal Morphologies.
Beltes, Panagiotis; Kalaitzoglou, Maria-Elpida; Kantilieraki, Eleni; Beltes, Charalampos; Angelopoulos, Christos
2017-08-01
This study aimed to analyze the external and internal morphologies of 3-rooted maxillary first premolars using cone-beam computed tomographic (CBCT) imaging. Fifty-six three-rooted maxillary first premolars were imaged by CBCT imaging and classified into 4 groups on the basis of external root morphology. Internal morphologic features, including the shapes of the buccal and palatal orifices and distances of bifurcation of the buccal-palatal and mesiobuccal-distobuccal root canals from the cementoenamel junction (CEJ), were measured. The teeth were classified into 4 groups on the basis of external morphology: group A, separation of the buccal and palatal roots with bifurcation of the former into the mesiobuccal and distobuccal roots (n = 22); group B, fusion of 2 buccal roots with the palatal root being separate (n = 19); group C, complete or partial fusion of the distobuccal and palatal roots (n = 9); and group D, fusion of all 3 roots (n = 6). The buccal orifice was mainly triangular/heart shaped. The distance of bifurcation of the buccal-palatal root canals from the CEJ in group A differed significantly from those in groups B and C (P < .05). There were significant differences in the distance of bifurcation of the mesiobuccal-distobuccal root canals from the CEJ among groups A, B, and C (P < .05). Four teeth exhibited C-shaped root canal systems of different configurations. The external and internal morphologies of 3-rooted maxillary first premolars vary considerably. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Homma, Yuto; Moriwaki, Hiroyuki; Ohki, Shigeo; Ikeda, Kazumi
2014-06-01
This paper deals with verification of three dimensional triangular prismatic discrete ordinates transport calculation code ENSEMBLE-TRIZ by comparison with multi-group Monte Carlo calculation code GMVP in a large fast breeder reactor. The reactor is a 750 MWe electric power sodium cooled reactor. Nuclear characteristics are calculated at beginning of cycle of an initial core and at beginning and end of cycle of equilibrium core. According to the calculations, the differences between the two methodologies are smaller than 0.0002 Δk in the multi-plication factor, relatively about 1% in the control rod reactivity, and 1% in the sodium void reactivity.
Intravenous nitroglycerin for external cephalic version: a randomized controlled trial.
Hilton, Jennifer; Allan, Bruce; Swaby, Cheryl; Wahba, Raouf; Wah, Raouf; Jarrell, John; Wood, Stephen; Ross, Sue; Tran, Quynh
2009-09-01
To estimate whether treatment with intravenous nitroglycerin for uterine relaxation increases the chance of successful external cephalic version. Two double-blind, randomized clinical trials were undertaken: one in nulliparous women and a second in multiparous women. Women presenting for external cephalic version at term were eligible to participate. The primary outcome was immediate success of external cephalic version. Other outcomes were presentation at delivery, cesarean delivery rate, and side effects and complications. Sample size calculations were based on a 100% increase in success of external cephalic version with a one-sided analysis and alpha=0.05 (80% power). In total, 126 women were recruited-82 in the nulliparous trial and 44 in the multiparous trial. Seven patients did not have external cephalic version before delivery but were included in the analysis of success of external cephalic version. One patient was lost to follow-up. The external cephalic version success rate for nulliparous patients was 24% (10 of 42) in patients who received nitroglycerin compared with 8% (3 of 40) in those who receive placebo (P=.04, one-sided Fisher exact test, odds ratio 3.85, lower bound 1.22). In multiparous patients, the external cephalic version success rate did not differ significantly between groups: 44% (10 of 23) in the nitroglycerin group compared with 43% (9 of 21) in the placebo group (P=.60). Treatment with intravenous nitroglycerin increased the rate of successful external cephalic version in nulliparous, but not in multiparous, women. Treatment with intravenous nitroglycerin appeared to be safe, but our numbers were too small to rule out rare serious adverse effects. I.
[Usage and efficacy of timolol maleate eye drops in treatment of superficial infantile hemangioma].
Wu, Qizhen; Shi, Qingmei; Long, Jianhong; Li, Jiaguang; Guo, Yu; Lei, Shaorong
2017-06-28
To determine drug dose and usage of timolol maleate eye drops in the treatment of superficial infantile hemangioma. Methods: A total of 250 superficial hemangioma infants were recruited and assigned into 5 groups (n=50 for each group): an external application group and 4 exterior coating groups (2, 4, 6, 8 times per day). We evaluated the therapeutic effect of different methods for drug application (external application or exterior coating) and the frequency for drug administration on superficial infantile hemangioma. Results: The external application group (twice a day and 0.5 hour per time) showed better effect than that in the exterior coating group with twice a day (P<0.001). The difference in therapeutic effect between the exterior coating group with 6 times a day and exterior coating group with twice a day or with 3 times a day was significant (P<0.001). The differences in drug efficacy were not found among the exterior coating group with 6 times a day, the exterior coating group with 8 times a day, or the external application group with twice a day (All P>0.05). Conclusion: Drug dose may affect the therapeutic effect of timolol maleate eye drops in superficial hemangioma infants, and exterior coating with 6 times a day may achieve the best curative effect.
An external focus of attention enhances balance learning in older adults.
Chiviacowsky, Suzete; Wulf, Gabriele; Wally, Raquel
2010-10-01
Studies with young adults have shown that an external focus of attention (i.e., on the movement effect) results in more effective motor learning and greater automaticity than an internal focus (i.e., on one's own body movements). The present study examined whether instructions inducing an external versus internal attentional focus would differentially affect the learning of a balance task in 32 older adults (24 females and 8 males, mean age: 69.4 years), divided equally, by number and gender, into two groups. The task required participants to stand on a balance platform (stabilometer) tilting to the left and right, and to try to keep the platform as close to horizontal as possible during each 30-s trial. The external focus group was instructed to concentrate on keeping markers on the platform horizontal, while the internal focus group was instructed to concentrate on keeping their feet horizontal. The dependent variable was time in balance (i.e., platform movements within ± 5°). Participants performed 10 practice trials on day 1, with focus reminders given before each trial. Learning was assessed by a retention test, consisting of five trials without instructions, performed 1 day later. The external focus group outperformed the internal focus group in retention [F(4, 120)=3.46, p=.01]. The results demonstrate that the learning benefits of an external attentional focus are generalizable to older learners. Copyright © 2010 Elsevier B.V. All rights reserved.
Moris, Izabela C M; Monteiro, Silas Borges; Martins, Raíssa; Ribeiro, Ricardo Faria; Gomes, Erica A
2018-01-01
To evaluate the influence of different manufacturing methods of single implant-supported metallic crowns on the internal and external marginal fit through computed microtomography. Forty external hexagon implants were divided into 4 groups ( n = 8), according to the manufacturing method: GC, conventional casting; GI, induction casting; GP, plasma casting; and GCAD, CAD/CAM machining. The crowns were attached to the implants with insertion torque of 30 N·cm. The external (vertical and horizontal) marginal fit and internal fit were assessed through computed microtomography. Internal and external marginal fit data ( μ m) were submitted to a one-way ANOVA and Tukey's test ( α = .05). Qualitative evaluation of the images was conducted by using micro-CT. The statistical analysis revealed no significant difference between the groups for vertical misfit ( P = 0.721). There was no significant difference ( P > 0.05) for the internal and horizontal marginal misfit in the groups GC, GI, and GP, but it was found for the group GCAD ( P ≤ 0.05). Qualitative analysis revealed that most of the samples of cast groups exhibited crowns underextension while the group GCAD showed overextension. The manufacturing method of the crowns influenced the accuracy of marginal fit between the prosthesis and implant. The best results were found for the crowns fabricated through CAD/CAM machining.
Ex vivo tracheomalacia model with 3D-printed external tracheal splint.
Kaye, Rachel; Goldstein, Todd; Aronowitz, Danielle; Grande, Daniel A; Zeltsman, David; Smith, Lee P
2017-04-01
To design and evaluate an ex vivo model of tracheomalacia with and without a three-dimensional (3D)-printed external tracheal splint. Prospective, ex vivo animal trial. Three groups of ex vivo porcine tracheas were used: 1) control (unmanipulated trachea), 2) tracheomalacia (tracheal rings partially incised and crushed), and 3) splinted tracheomalacia (external custom tracheal splint fitted onto group 2 trachea). Each end of an ex vivo trachea was sealed with a custom-designed and 3D-printed cap; a transducer was placed through one end to measure the pressure inside the trachea. Although the negative pressure was applied to the tracheal lumen, the tracheal wall collapse was measured externally and internally using a bronchoscope. Each group had at least three recorded trials. Tracheal diameter was evaluated using ImageJ software (National Institutes of Health, Bethesda, MD) and was averaged between two raters. Average tracheal occlusion percentage was compared using Student t test. The average occlusion was 31% for group 1, 87.4% for group 2, and 20% for group 3. Significant differences were found between the control and tracheomalacia groups (P < 0.01) and the tracheomalacia and splinted tracheomalacia groups (P < 0.01). There was no significant difference between the control and splinted tracheomalacia groups (P = 0.13). Applied pressure was plotted against occlusion and regression line slope differed between the tracheomalacia (0.91) and control (0.12) or splinted tracheomalacia (0.39) groups. We demonstrate the potential for an ex vivo tracheomalacia model to reproduce airway collapse and show that this collapse can be treated successfully with a 3D-printed external splint. These results are promising and justify further studies. N/A. Laryngoscope, 127:950-955, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.
Kuppusamy, Vijayalakshmi; Nagarajan, Vivekanandan; Jeevanandam, Prakash; Murugan, Lavanya
2016-02-01
The study was aimed to compare two different monitor unit (MU) or dose verification software in volumetric modulated arc therapy (VMAT) using modified Clarkson's integration technique for 6 MV photons beams. In-house Excel Spreadsheet based monitor unit verification calculation (MUVC) program and PTW's DIAMOND secondary check software (SCS), version-6 were used as a secondary check to verify the monitor unit (MU) or dose calculated by treatment planning system (TPS). In this study 180 patients were grouped into 61 head and neck, 39 thorax and 80 pelvic sites. Verification plans are created using PTW OCTAVIUS-4D phantom and also measured using 729 detector chamber and array with isocentre as the suitable point of measurement for each field. In the analysis of 154 clinically approved VMAT plans with isocentre at a region above -350 HU, using heterogeneity corrections, In-house Spreadsheet based MUVC program and Diamond SCS showed good agreement TPS. The overall percentage average deviations for all sites were (-0.93% + 1.59%) and (1.37% + 2.72%) for In-house Excel Spreadsheet based MUVC program and Diamond SCS respectively. For 26 clinically approved VMAT plans with isocentre at a region below -350 HU showed higher variations for both In-house Spreadsheet based MUVC program and Diamond SCS. It can be concluded that for patient specific quality assurance (QA), the In-house Excel Spreadsheet based MUVC program and Diamond SCS can be used as a simple and fast accompanying to measurement based verification for plans with isocentre at a region above -350 HU. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
DeCruze, B; Guthrie, D
1999-01-01
Poor prognosis (poorly differentiated and/or deep myometrial invasion) Stage I endometrial cancer can have a relapse rate as high as 50%. Traditionally, most clinical oncologists treat these patients with external beam radiotherapy after surgery but there is no evidence to show that this improves survival. The retrospective study looks at the results of not giving external beam radiotherapy in 25 consecutive patients and compares the results with a group of 13 consecutive patients who did have such treatment. The two groups were comparable with regard to age, degree of differentiation and degree of invasion. Survival was comparable in the two groups. There is no evidence of any obvious decrease in survival from withholding external beam radiotherapy, but this was not a prospective randomized controlled trial. This study illustrates that it is essential that the Medical Research Council ASTEC trial should be supported because this will determine the true place of external beam radiotherapy in such patients.
Canbulat Şahiner, Nejla; İnal, Sevil; Sevim Akbay, Ayşe
2015-06-01
Procedures involving needles are the most common and major sources of pain in children. External cold and vibration via Buzzy (MMJ Labs, Atlanta, GA) is a method that combines cooling and vibration. This study investigated the effect of the combined stimulation of skin with external cold and vibration via Buzzy on the pain and anxiety levels in children during immunization. This study was a prospective, randomized controlled trial. Children were randomized into two groups: experimental (external cold and Buzzy) and control (no intervention). The pain and anxiety levels of the children were assessed using the Wong-Baker FACES scale and Children Fear Scale. The experimental group showed significantly lower pain and anxiety levels than the control group during immunization. The combined stimulation of skin with external cold and vibration can be used to reduce pain and anxiety during pediatric immunization. Copyright © 2015 American Society of PeriAnesthesia Nurses. Published by Elsevier Inc. All rights reserved.
ETV works in partnership with recognized standards and testing organizations and stakeholder groups consisting of regulators, buyers, and vendor organizations, with the full participation of individual technology developers. The program evaluates the performance of innovative
Simscape Modeling Verification in the Simulink Development Environment
NASA Technical Reports Server (NTRS)
Volle, Christopher E. E.
2014-01-01
The purpose of the Simulation Product Group of the Control and Data Systems division of the NASA Engineering branch at Kennedy Space Center is to provide a realtime model and simulation of the Ground Subsystems participating in vehicle launching activities. The simulation software is part of the Spaceport Command and Control System (SCCS) and is designed to support integrated launch operation software verification, and console operator training. Using Mathworks Simulink tools, modeling engineers currently build models from the custom-built blocks to accurately represent ground hardware. This is time consuming and costly due to required rigorous testing and peer reviews to be conducted for each custom-built block. Using Mathworks Simscape tools, modeling time can be reduced since there would be no custom-code developed. After careful research, the group came to the conclusion it is feasible to use Simscape's blocks in MatLab's Simulink. My project this fall was to verify the accuracy of the Crew Access Arm model developed using Simscape tools running in the Simulink development environment.
The SeaHorn Verification Framework
NASA Technical Reports Server (NTRS)
Gurfinkel, Arie; Kahsai, Temesghen; Komuravelli, Anvesh; Navas, Jorge A.
2015-01-01
In this paper, we present SeaHorn, a software verification framework. The key distinguishing feature of SeaHorn is its modular design that separates the concerns of the syntax of the programming language, its operational semantics, and the verification semantics. SeaHorn encompasses several novelties: it (a) encodes verification conditions using an efficient yet precise inter-procedural technique, (b) provides flexibility in the verification semantics to allow different levels of precision, (c) leverages the state-of-the-art in software model checking and abstract interpretation for verification, and (d) uses Horn-clauses as an intermediate language to represent verification conditions which simplifies interfacing with multiple verification tools based on Horn-clauses. SeaHorn provides users with a powerful verification tool and researchers with an extensible and customizable framework for experimenting with new software verification techniques. The effectiveness and scalability of SeaHorn are demonstrated by an extensive experimental evaluation using benchmarks from SV-COMP 2015 and real avionics code.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cheng, Jing-Jy; Flood, Paul E.; LePoire, David
In this report, the results generated by RESRAD-RDD version 2.01 are compared with those produced by RESRAD-RDD version 1.7 for different scenarios with different sets of input parameters. RESRAD-RDD version 1.7 is spreadsheet-driven, performing calculations with Microsoft Excel spreadsheets. RESRAD-RDD version 2.01 revamped version 1.7 by using command-driven programs designed with Visual Basic.NET to direct calculations with data saved in Microsoft Access database, and re-facing the graphical user interface (GUI) to provide more flexibility and choices in guideline derivation. Because version 1.7 and version 2.01 perform the same calculations, the comparison of their results serves as verification of both versions.more » The verification covered calculation results for 11 radionuclides included in both versions: Am-241, Cf-252, Cm-244, Co-60, Cs-137, Ir-192, Po-210, Pu-238, Pu-239, Ra-226, and Sr-90. At first, all nuclidespecific data used in both versions were compared to ensure that they are identical. Then generic operational guidelines and measurement-based radiation doses or stay times associated with a specific operational guideline group were calculated with both versions using different sets of input parameters, and the results obtained with the same set of input parameters were compared. A total of 12 sets of input parameters were used for the verification, and the comparison was performed for each operational guideline group, from A to G, sequentially. The verification shows that RESRAD-RDD version 1.7 and RESRAD-RDD version 2.01 generate almost identical results; the slight differences could be attributed to differences in numerical precision with Microsoft Excel and Visual Basic.NET. RESRAD-RDD version 2.01 allows the selection of different units for use in reporting calculation results. The results of SI units were obtained and compared with the base results (in traditional units) used for comparison with version 1.7. The comparison shows that RESRAD-RDD version 2.01 correctly reports calculation results in the unit specified in the GUI.« less
Diffraction-based analysis of tunnel size for a scaled external occulter testbed
NASA Astrophysics Data System (ADS)
Sirbu, Dan; Kasdin, N. Jeremy; Vanderbei, Robert J.
2016-07-01
For performance verification of an external occulter mask (also called a starshade), scaled testbeds have been developed to measure the suppression of the occulter shadow in the pupil plane and contrast in the image plane. For occulter experiments the scaling is typically performed by maintaining an equivalent Fresnel number. The original Princeton occulter testbed was oversized with respect to both input beam and shadow propagation to limit any diffraction effects due to finite testbed enclosure edges; however, to operate at realistic space-mission equivalent Fresnel numbers an extended testbed is currently under construction. With the longer propagation distances involved, diffraction effects due to the edge of the tunnel must now be considered in the experiment design. Here, we present a diffraction-based model of two separate tunnel effects. First, we consider the effect of tunnel-edge induced diffraction ringing upstream from the occulter mask. Second, we consider the diffraction effect due to clipping of the output shadow by the tunnel downstream from the occulter mask. These calculations are performed for a representative point design relevant to the new Princeton occulter experiment, but we also present an analytical relation that can be used for other propagation distances.
NASA Astrophysics Data System (ADS)
Chun, Myung-Suk; Chun, Byoungjin; Lee, Ji-Young; Complex Fluids Team
2016-11-01
We investigate the externally time-dependent pulsatile electrokinetic viscous flows by extending the previous simulations concerning the electrokinetic microfluidics for different geometries. The external body force originated from between the nonlinear Poisson-Boltzmann field and the flow-induced electric field is employed in the Cauchy momentum equation, and then the Nernst-Planck equation in connection with the net current conservation is coupled. Our explicit model allows one to quantify the effects of the oscillating frequency and conductance of the Stern layer, considering the shear thinning effect and the strong electric double layer interaction. This presentation reports the new results regarding the implication of optimum frequency pressure pulsations toward realizing mechanical to electrical energy transfer with high conversion efficiencies. These combined factors for different channel dimension are examined in depth to obtain possible enhancements of streaming current, with taking advantage of pulsating pressure field. From experimental verifications by using electrokinetic power chip, it is concluded that our theoretical framework can serve as a useful basis for micro/nanofluidics design and potential applications to the enhanced energy conversion. NRF of Korea (No.2015R1A2A1A15052979) and KIST (No.2E26490).
1999-02-11
KENNEDY SPACE CENTER, FLA. -- In the SPACEHAB Facility for a payload Interface Verification Test (IVT) for their upcoming mission to the International Space Station are (left to right) Mission Specialists Valery Tokarev, Julie Payette (holding a lithium hydroxide canister) and Dan Barry. Other crew members at KSC for the IVT are Commander Kent Rominger, Pilot Rick Husband and Mission Specialists Ellen Ochoa and Tamara Jernigan. Mission STS-96 carries the SPACEHAB Logistics Double Module, which has equipment to further outfit the International Space Station service module and equipment that can be off-loaded from the early U.S. assembly flights. The SPACEHAB carries internal logistics and resupply cargo for station outfitting, plus an external Russian cargo crane to be mounted to the exterior of the Russian station segment and used to perform space walking maintenance activities. The double module stowage provides capacity of up to 10,000 lbs. with the ability to accommodate powered payloads, four external rooftop stowage locations, four double-rack locations (two powered), up to 61 bulkhead-mounted middeck locker locations, and floor storage for large unique items and Soft Stowage. STS-96 is targeted to launch May 20 about 9:32 a.m
Deaths on board ships assisted by the Centro Internazionale Radio Medico in the last 25 years.
Grappasonni, Iolanda; Petrelli, Fabio; Amenta, Francesco
2012-07-01
Data on occupational diseases of seafarers and of causes of death during their career are sparse. The causes of deaths on board ships assisted by Centro Internazionale Radio Medico (CIRM), the Italian Telemedical Maritime Assistance Service (TMAS) were reviewed by examining 29,146 files of patients treated from 1986 to 2010. In the 25 years, 383 deaths occurred (1.31%). Diseases of the circulation were the most frequent, followed by external causes such as accidents and violence, infectious and parasitic diseases, alcohol and drug addiction, respiratory system diseases. Cardiovascular and external causes were the principal causes of deaths among seafarers. This investigation is the first study on the causes of death on board ships obtained from data of a maritime telemedical centre, that has assisted seafarers when they were alive or immediately after their death. The fact that diseases of the circulatory system are the first cause of death of sailing seafarers deserves specific initiatives. They should include campaigns for adequate lifestyles and the availability on ships of medical devices useful for diagnostic purposes, resuscitation as well as for verification of death. Copyright © 2012 Elsevier Ltd. All rights reserved.
Scanning electron microscope fractography in failure analysis of steels
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wouters, R.; Froyen, L.
1996-04-01
For many failure cases, macroscopic examination of the fracture surface permits discrimination of fatigue fractures from overload fractures. For clarifying fatigue fractures, the practical significance of microfractography is limited to an investigation of the crack initiation areas. Scanning electron microscopy is successfully used in tracing local material abnormalities that act as fatigue crack initiators. The task for the scanning electron microscope, however, is much more substantial in failure analysis of overload fractures, especially for steels. By revealing specific fractographic characteristics, complemented by information about the material and the loading conditions, scanning electron microscopy provides a strong indication of the probablemore » cause of failure. A complete dimple fracture is indicative of acceptable bulk material properties; overloading, by subdimensioning or excessive external loading, has to be verified. The presence of cleavage fracture makes the material properties questionable if external conditions causing embrittlement are absent. Intergranular brittle fracture requires verification of grain-boundary weakening conditions--a sensitized structure, whether or not combined with a local stress state or a specific environment. The role of scanning electron microscopy in failure analysis is illustrated by case histories of the aforementioned fracture types.« less
Deng, Chunyan; Xie, Han; Ye, Xuejie; Zhang, Haoran; Liu, Maodian; Tong, Yindong; Ou, Langbo; Yuan, Wen; Zhang, Wei; Wang, Xuejun
2016-12-01
Risk assessments for human health have been conducted for municipal solid waste incinerators (MSWIs) in many western countries, whereas only a few risk assessments have been performed for MSWIs in developing countries such as China where the use of waste incineration is increasing rapidly. To assess the mercury exposure risks of a population living near the largest MSWI in South China, we combined internal exposure and external exposure assessment with an individual-specific questionnaire. The mercury concentrations in air, soil, and locally collected food around the MSWI were assessed. The total mercury (T-Hg) and methylmercury (MeHg) of 447 blood samples from a control group, residential exposure group, and MSWI workers were measured. The internal and external exposures of the subject population were analyzed. Significant difference in MeHg concentrations was observed between the control group and the exposed group, between the control group and the MSWI workers, and between the exposed group and the MSWI workers (median levels: 0.70 μg/L, 0.81 μg/L, and 1.02 μg/L for the control group, exposed group, and MSWI workers, respectively). The MeHg/T-Hg ratio was 0.51 ± 0.19, 0.59 ± 0.17 and 0.58 ± 0.25, respectively. Multiple linear regression analysis indicated that MeHg concentrations were positively correlated with the gaseous mercury in the air. Combining internal and external exposure assessment showed that the direct contribution of MSWI emissions was minor compared with the dietary contribution. The external and internal exposures were well matched with each other. This study also suggested that an integrated method combining internal and external exposure assessment with an individual-specific questionnaire is feasible to assess the risks for a population living near a MSWI. Copyright © 2016 Elsevier Ltd. All rights reserved.
Transistor step stress program for JANTX2N2945A
NASA Technical Reports Server (NTRS)
1979-01-01
Data compiled for the purpose of evaluating the effect of power/temperature step stress when applied to the transistor JANTX2N2945A manufactured by Raytheon and Teledyne is presented. A total of 48 samples from each manufacturer was divided equally (16 per group) into three groups and submitted to the processes outlined. In addition, two control units were maintained for verification of the electrical parametric testing.
ERIC Educational Resources Information Center
Plowman, Sharon Ann
The use of health-related physical fitness tests for sex-fair ability grouping in physical education classes requires the verification of two assumptions: (1) that there exists a direct positive relationship between health-related physical fitness and development and/or improvement of various sport skills; and (2) that there is a physiological…
Land, Sander; Gurev, Viatcheslav; Arens, Sander; Augustin, Christoph M; Baron, Lukas; Blake, Robert; Bradley, Chris; Castro, Sebastian; Crozier, Andrew; Favino, Marco; Fastl, Thomas E; Fritz, Thomas; Gao, Hao; Gizzi, Alessio; Griffith, Boyce E; Hurtado, Daniel E; Krause, Rolf; Luo, Xiaoyu; Nash, Martyn P; Pezzuto, Simone; Plank, Gernot; Rossi, Simone; Ruprecht, Daniel; Seemann, Gunnar; Smith, Nicolas P; Sundnes, Joakim; Rice, J Jeremy; Trayanova, Natalia; Wang, Dafang; Jenny Wang, Zhinuo; Niederer, Steven A
2015-12-08
Models of cardiac mechanics are increasingly used to investigate cardiac physiology. These models are characterized by a high level of complexity, including the particular anisotropic material properties of biological tissue and the actively contracting material. A large number of independent simulation codes have been developed, but a consistent way of verifying the accuracy and replicability of simulations is lacking. To aid in the verification of current and future cardiac mechanics solvers, this study provides three benchmark problems for cardiac mechanics. These benchmark problems test the ability to accurately simulate pressure-type forces that depend on the deformed objects geometry, anisotropic and spatially varying material properties similar to those seen in the left ventricle and active contractile forces. The benchmark was solved by 11 different groups to generate consensus solutions, with typical differences in higher-resolution solutions at approximately 0.5%, and consistent results between linear, quadratic and cubic finite elements as well as different approaches to simulating incompressible materials. Online tools and solutions are made available to allow these tests to be effectively used in verification of future cardiac mechanics software.
Cognitive and neural mechanisms of decision biases in recognition memory.
Windmann, Sabine; Urbach, Thomas P; Kutas, Marta
2002-08-01
In recognition memory tasks, stimuli can be classified as "old" either on the basis of accurate memory or a bias to respond "old", yet bias has received little attention in the cognitive neuroscience literature. Here we examined the pattern and timing of bias-related effects in event-related brain potentials (ERPs) to determine whether the bias is linked more to memory retrieval or to response verification processes. Participants were divided into a High Bias and a Low Bias group according to their bias to respond "old". These groups did not differ in recognition accuracy or in the ERP pattern to items that actually were old versus new (Objective Old/New Effect). However, when the old/new distinction was based on each subject's perspective, i.e. when items judged "old" were compared with those judged "new" (Subjective Old/New Effect), significant group differences were observed over prefrontal sites with a timing (300-500 ms poststimulus) more consistent with bias acting early on memory retrieval processes than on post-retrieval response verification processes. In the standard old/new effect (Hits vs Correct Rejections), these group differences were intermediate to those for the Objective and the Subjective comparisons, indicating that such comparisons are confounded by response bias. We propose that these biases are top-down controlled processes mediated by prefrontal cortex areas.
An evaluation of reading comprehension of expository text in adults with traumatic brain injury.
Sohlberg, McKay Moore; Griffiths, Gina G; Fickas, Stephen
2014-05-01
This project was conducted to obtain information about reading problems of adults with traumatic brain injury (TBI) with mild-to-moderate cognitive impairments and to investigate how these readers respond to reading comprehension strategy prompts integrated into digital versions of text. Participants from 2 groups, adults with TBI (n = 15) and matched controls (n = 15), read 4 different 500-word expository science passages linked to either a strategy prompt condition or a no-strategy prompt condition. The participants' reading comprehension was evaluated using sentence verification and free recall tasks. The TBI and control groups exhibited significant differences on 2 of the 5 reading comprehension measures: paraphrase statements on a sentence verification task and communication units on a free recall task. Unexpected group differences were noted on the participants' prerequisite reading skills. For the within-group comparison, participants showed significantly higher reading comprehension scores on 2 free recall measures: words per communication unit and type-token ratio. There were no significant interactions. The results help to elucidate the nature of reading comprehension in adults with TBI with mild-to-moderate cognitive impairments and endorse further evaluation of reading comprehension strategies as a potential intervention option for these individuals. Future research is needed to better understand how individual differences influence a person's reading and response to intervention.
Onan, Arif; Simsek, Nurettin
2017-04-01
Automated external defibrillators are pervasive computing devices designed for the treatment and management of acute sudden cardiac arrest. This study aims to explain users' actual use behavior in teams formed by different professions taken after a short time span of interaction with automated external defibrillator. Before the intervention, all the participants were certified with the American Heart Association Basic Life Support for healthcare providers. A statistically significant difference was revealed in mean individual automated external defibrillator technical skills between uniprofessional and interprofessional groups. The technical automated external defibrillator team scores were greater for groups with interprofessional than for those with uniprofessional education. The nontechnical automated external defibrillator skills of interprofessional and uniprofessional teams revealed differences in advantage of interprofessional teams. Students positively accept automated external defibrillators if well-defined and validated training opportunities to use them expertly are available. Uniprofessional teams were successfully supported by their members and, thereby, used automated external defibrillator effectively. Furthermore, the interprofessional approach resulted in as much effective teamwork as the uniprofessional approach.
Ilizarov bone transport versus fibular graft for reconstruction of tibial bone defects in children.
Abdelkhalek, Mostafa; El-Alfy, Barakat; Ali, Ayman M
2016-11-01
The aim of this study was to compare the results of treatment of segmental tibial defects in the pediatric age group using an Ilizarov external fixator versus a nonvascularized fibular bone graft. This study included 24 patients (age range from 5.5 to 15 years) with tibial bone defects: 13 patients were treated with bone transport (BT) and 11 patients were treated with a nonvascularized fibular graft (FG). The outcome parameters were bone results (union, deformity, infection, leg-length discrepancy) and functional results: external fixation index and external fixation time. In group A (BT), one patient developed refracture at the regenerate site, whereas, in group B (FG), after removal of the external fixator, one of the FGs developed a stress fracture. The external fixator time in group A was 10.7 months (range 8-14.5) versus 7.8 months (range 4-11.5 months) in group B (FG). In group A (BT), one patient had a limb-length discrepancy (LLD), whereas, in group B (FG), three patients had LLD. The functional and bone results of the Ilizarov BT technique were excellent in 23.1 and 30.8%, good in 38.5 and 46.2, fair in 30.8 and 15.4, and poor in 7.6 and 7.6%, respectively. The poor functional result was related to the poor bone result because of prolonged external fixator time resulting in significant pain, limited ankle motion, whereas the functional and bone results of fibular grafting were excellent in 9.1 and 18.2%, good in 63.6 and 45.5%, fair in 18.2 and 27.2%, and poor in 9.1 and 9.1%, respectively. Segmental tibial defects can be effectively treated with both methods. The FG method provides satisfactory results, with early removal of the external fixator. However, it had a limitation in patients with severe infection and those with LLD. Also, it requires a long duration of limb bracing until adequate hypertrophy of the graft. The Ilizarov method has the advantages of early weight bearing, treatment of postinfection bone defect in a one-stage surgery, and the possibility to treat the associated LLD. However, it has a long external fixation time.
Lin, Hong; Wang, Yu-feng; Wu, Ye-ping
2007-06-18
To evaluate the effectiveness on the prevention of behavior problems of life skills education combining school-based and parent-involved approaches for third-grade students in China. This research was targeted at the population of third-grade children in two elementary schools in Qinhuangdao City, Hebei Province. Nine regular school classrooms were randomly divided into three groups: the intervention group (n=208), internal control group (n=209) and external control group (n=204). The intervention included 26-hour competence promotion for students and 5-hour parent training. The Rutter Scale by parent and teacher were used to evaluate the effects at pretest, posttest and 6-month follow-up. Improvement was observed among children in the intervention group than those in the control groups. The statistical difference was significant (P<0.05).1.The prevalence of total behavior problems, antisocial behavior and neurotic behavior problem at home: At termination, the prevalence in intervention group(11.2%,3.6% and 6.1%)was lower (except neurotic behavior) than those in internal control group (19.4%,5.6% and 6.1%)and external control group (18.9%,8.9% and 5.3%). At 6-month follow-up, the prevalence in intervention group (10.2%,2.5% and 3.6%)was still lower than those in internal control group (17.2%,6.8% and 6.8%)and external control group (17.8%,7.8% and 6.7%).2. The prevalence of total behavior problems and antisocial behavior problem at school: At termination, the prevalence in intervention group(5.3% and 4.3%)was lower than those in internal control group(10.1% and 7.7%)and external control group(14.9% and 12.4%). At 6-month follow-up, the prevalence in intervention group(2.9% and 2.4%)was still lower than those in internal control group (10.2% and 9.7%)and external control group(11.3% and 10.3%). Life skills education could reduce the children's home and school behavior problems, especially for antisocial behavior. The effects of intervention maintained during the 6-month follow-up study.
GHG MITIGATION TECHNOLOGY PERFORMANCE EVALUATIONS UNDERWAY AT THE GHG TECHNOLOGY VERIFICATION CENTER
The paper outlines the verification approach and activities of the Greenhouse Gas (GHG) Technology Verification Center, one of 12 independent verification entities operating under the U.S. EPA-sponsored Environmental Technology Verification (ETV) program. (NOTE: The ETV program...
Integrated Medical Model Verification, Validation, and Credibility
NASA Technical Reports Server (NTRS)
Walton, Marlei; Kerstman, Eric; Foy, Millennia; Shah, Ronak; Saile, Lynn; Boley, Lynn; Butler, Doug; Myers, Jerry
2014-01-01
The Integrated Medical Model (IMM) was designed to forecast relative changes for a specified set of crew health and mission success risk metrics by using a probabilistic (stochastic process) model based on historical data, cohort data, and subject matter expert opinion. A probabilistic approach is taken since exact (deterministic) results would not appropriately reflect the uncertainty in the IMM inputs. Once the IMM was conceptualized, a plan was needed to rigorously assess input information, framework and code, and output results of the IMM, and ensure that end user requests and requirements were considered during all stages of model development and implementation. METHODS: In 2008, the IMM team developed a comprehensive verification and validation (VV) plan, which specified internal and external review criteria encompassing 1) verification of data and IMM structure to ensure proper implementation of the IMM, 2) several validation techniques to confirm that the simulation capability of the IMM appropriately represents occurrences and consequences of medical conditions during space missions, and 3) credibility processes to develop user confidence in the information derived from the IMM. When the NASA-STD-7009 (7009) was published, the IMM team updated their verification, validation, and credibility (VVC) project plan to meet 7009 requirements and include 7009 tools in reporting VVC status of the IMM. RESULTS: IMM VVC updates are compiled recurrently and include 7009 Compliance and Credibility matrices, IMM VV Plan status, and a synopsis of any changes or updates to the IMM during the reporting period. Reporting tools have evolved over the lifetime of the IMM project to better communicate VVC status. This has included refining original 7009 methodology with augmentation from the NASA-STD-7009 Guidance Document. End user requests and requirements are being satisfied as evidenced by ISS Program acceptance of IMM risk forecasts, transition to an operational model and simulation tool, and completion of service requests from a broad end user consortium including Operations, Science and Technology Planning, and Exploration Planning. CONCLUSIONS: The VVC approach established by the IMM project of combining the IMM VV Plan with 7009 requirements is comprehensive and includes the involvement of end users at every stage in IMM evolution. Methods and techniques used to quantify the VVC status of the IMM have not only received approval from the local NASA community but have also garnered recognition by other federal agencies seeking to develop similar guidelines in the medical modeling community.
Group specializes in the research, development and deployment of software that support the design and controls design, the Spawn of EnergyPlus next-generation simulation engine, for building and control energy systems tools for OpenBuildingControl to support control design, deployment and verification of building
33 CFR 385.20 - Restoration Coordination and Verification (RECOVER).
Code of Federal Regulations, 2010 CFR
2010-07-01
... Water Management District to conduct assessment, evaluation, and planning and integration activities... ensuring that the goals and purposes of the Plan are achieved. RECOVER has been organized into a Leadership Group that provides management and coordination for the activities of RECOVER and teams that accomplish...
Digital Video of Live-Scan Fingerprint Data
National Institute of Standards and Technology Data Gateway
NIST Digital Video of Live-Scan Fingerprint Data (PC database for purchase) NIST Special Database 24 contains MPEG-2 (Moving Picture Experts Group) compressed digital video of live-scan fingerprint data. The database is being distributed for use in developing and testing of fingerprint verification systems.
ETV works in partnership with recognized standards and testing organizations and stakeholder groups consisting of regulators, buyers, and vendor organizations, with the full participation of individual technology developers. The program evaluates the performance of innovative
ETV works in partnership with recognized standards and testing organizations and stakeholder groups consisting of regulators, buyers, and vendor organizations, with the full participation of individual technology developers. The program evaluates the performance of innovative
Pino, María J; Castillo, Rosa A; Raya, Antonio; Herruzo, Javier
2017-11-09
To identify possible differences in the level of externalizing behavior problems among children with and without hearing impairment and determine whether any relationship exists between this type of problem and parenting practices. The Behavior Assessment System for Children was used to evaluate externalizing variables in a sample of 118 boys and girls divided into two matched groups: 59 with hearing disorders and 59 normal-hearing controls. Significant between-group differences were found in hyperactivity, behavioral problems, and externalizing problems, but not in aggression. Significant differences were also found in various aspects of parenting styles. A model for predicting externalizing behavior problems was constructed, achieving a predicted explained variance of 50%. Significant differences do exist between adaptation levels in children with and without hearing impairment. Parenting style also plays an important role.
Chutz, Noah; Skutsch, Margaret
2016-01-01
There have been many calls for community participation in MRV (measuring, reporting, verification) for REDD+. This paper examines whether community involvement in MRV is a requirement, why it appears desirable to REDD+ agencies and external actors, and under what conditions communities might be interested in participating. It asks What’s in it for communities? What might communities gain from such an involvement? What could they lose? It embraces a broader approach which we call community MMM which involves mapping, measuring and monitoring of forest and other natural resources for issues which are of interest to the community itself. We focus on cases in México because the country has an unusually high proportion of forests under community communal ownership. In particular, we refer to a recent REDD+ initiative—CONAFOR-LAIF, in which local communities select and approve local people to participate in community-based monitoring activities. From these local initiatives we identify the specific and the general drivers for communities to be involved in mapping, measuring and monitoring of their own territories and their natural resources. We present evidence that communities are more interested in this wider approach than in a narrow focus on carbon monitoring. Finally we review what the challenges to reconciling MMM with MRV requirements are likely to be. PMID:27300439
Lu, Yanyan; Hao, Chunyan; He, Wubin; Tang, Can; Shao, Zhenya
2018-01-01
Various types of complications arising from intravenous indwelling needles have become a challenge in clinical care. It is urgent to seek a simple and cost-effective method for prevention and treatment of phlebitis. We investigated the roles of mirabilite in preventing and treating phlebitis caused by intravenous indwelling needles and provide guidance for prevention and treatment of mechanical phlebitis caused by intravenous indwelling needles. A total of 57 healthy congeneric big-eared New Zealand rabbits were randomly divided into 3 groups: blank control, indwelling needle, and group with external application of mirabilite. The ear vein of each rabbit was punctured with an intravenous indwelling needle. The ear vein specimens were taken at 3, 5, and 7 days after indwelling. The hematoxylin and eosin stained pathological tissue sections of the ear veins of the rabbits in each group were observed. The expression levels of IL-1 and IL-6, and tumour necrosis factor-α (TNF-α) in the vascular tissue of the ear veins of the rabbits in each group were detected with the immunofluorescence method. In the blank control group, there was no inflammatory cellular infiltration and no proliferation of fibrous tissue around the vascular wall. With the increase of the indwelling time, proliferation of fibrous tissue in vascular wall, increased inflammatory cellular infiltration and organized thrombus in the vascular tissue occurred in the ear veins of the rabbits in the indwelling needle group and group with external application of mirabilite. Compared with the indwelling needle group, the group with external application of mirabilite had significantly decreased fibrous tissue in the vascular wall and significantly decreased inflammatory cellular infiltration. At the same point in indwelling time, the expression levels of IL-1, IL-6, and TNF-α in the indwelling needle and group with external application of mirabilite were significantly higher than that in the blank control group (P<0.05). The expression levels of IL-1, IL-6, and TNF-α in the group with external application of mirabilite were lower than that in the indwelling needle group (P<0.05). The expression levels of IL-1, IL-6, and TNF-α are positively correlated with the indwelling time within the same group at different points in time. In conclusion, external application of mirabilite can significantly decrease infiltration of venous inflammatory cells of the rabbit ear margin, proliferation of fibrous tissue and thrombosis in the vascular wall, significant decrease the expression levels of IL-1, IL-6, and TNF-α in the mechanical phlebitis caused by intravenous indwelling needles, and decrease the inflammatory responses of the ear veins of rabbits. PMID:29250150
Lu, Yanyan; Hao, Chunyan; He, Wubin; Tang, Can; Shao, Zhenya
2018-01-01
Various types of complications arising from intravenous indwelling needles have become a challenge in clinical care. It is urgent to seek a simple and cost-effective method for prevention and treatment of phlebitis. We investigated the roles of mirabilite in preventing and treating phlebitis caused by intravenous indwelling needles and provide guidance for prevention and treatment of mechanical phlebitis caused by intravenous indwelling needles. A total of 57 healthy congeneric big-eared New Zealand rabbits were randomly divided into 3 groups: blank control, indwelling needle, and group with external application of mirabilite. The ear vein of each rabbit was punctured with an intravenous indwelling needle. The ear vein specimens were taken at 3, 5, and 7 days after indwelling. The hematoxylin and eosin stained pathological tissue sections of the ear veins of the rabbits in each group were observed. The expression levels of IL-1 and IL-6, and tumour necrosis factor-α (TNF-α) in the vascular tissue of the ear veins of the rabbits in each group were detected with the immunofluorescence method. In the blank control group, there was no inflammatory cellular infiltration and no proliferation of fibrous tissue around the vascular wall. With the increase of the indwelling time, proliferation of fibrous tissue in vascular wall, increased inflammatory cellular infiltration and organized thrombus in the vascular tissue occurred in the ear veins of the rabbits in the indwelling needle group and group with external application of mirabilite. Compared with the indwelling needle group, the group with external application of mirabilite had significantly decreased fibrous tissue in the vascular wall and significantly decreased inflammatory cellular infiltration. At the same point in indwelling time, the expression levels of IL-1, IL-6, and TNF-α in the indwelling needle and group with external application of mirabilite were significantly higher than that in the blank control group (P<0.05). The expression levels of IL-1, IL-6, and TNF-α in the group with external application of mirabilite were lower than that in the indwelling needle group (P<0.05). The expression levels of IL-1, IL-6, and TNF-α are positively correlated with the indwelling time within the same group at different points in time. In conclusion, external application of mirabilite can significantly decrease infiltration of venous inflammatory cells of the rabbit ear margin, proliferation of fibrous tissue and thrombosis in the vascular wall, significant decrease the expression levels of IL-1, IL-6, and TNF-α in the mechanical phlebitis caused by intravenous indwelling needles, and decrease the inflammatory responses of the ear veins of rabbits.
18 CFR 281.213 - Data Verification Committee.
Code of Federal Regulations, 2011 CFR
2011-04-01
... preparation. (e) The Data Verification Committee shall prepare a report concerning the proposed index of... 18 Conservation of Power and Water Resources 1 2011-04-01 2011-04-01 false Data Verification....213 Data Verification Committee. (a) Each interstate pipeline shall establish a Data Verification...
18 CFR 281.213 - Data Verification Committee.
Code of Federal Regulations, 2010 CFR
2010-04-01
... preparation. (e) The Data Verification Committee shall prepare a report concerning the proposed index of... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Data Verification....213 Data Verification Committee. (a) Each interstate pipeline shall establish a Data Verification...
The politics of verification and the control of nuclear tests, 1945-1980
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gallagher, N.W.
1990-01-01
This dissertation addresses two questions: (1) why has agreement been reached on verification regimes to support some arms control accords but not others; and (2) what determines the extent to which verification arrangements promote stable cooperation. This study develops an alternative framework for analysis by examining the politics of verification at two levels. The logical politics of verification are shaped by the structure of the problem of evaluating cooperation under semi-anarchical conditions. The practical politics of verification are driven by players' attempts to use verification arguments to promote their desired security outcome. The historical material shows that agreements on verificationmore » regimes are reached when key domestic and international players desire an arms control accord and believe that workable verification will not have intolerable costs. Clearer understanding of how verification is itself a political problem, and how players manipulate it to promote other goals is necessary if the politics of verification are to support rather than undermine the development of stable cooperation.« less
Investigation, Development, and Evaluation of Performance Proving for Fault-tolerant Computers
NASA Technical Reports Server (NTRS)
Levitt, K. N.; Schwartz, R.; Hare, D.; Moore, J. S.; Melliar-Smith, P. M.; Shostak, R. E.; Boyer, R. S.; Green, M. W.; Elliott, W. D.
1983-01-01
A number of methodologies for verifying systems and computer based tools that assist users in verifying their systems were developed. These tools were applied to verify in part the SIFT ultrareliable aircraft computer. Topics covered included: STP theorem prover; design verification of SIFT; high level language code verification; assembly language level verification; numerical algorithm verification; verification of flight control programs; and verification of hardware logic.
NASA Technical Reports Server (NTRS)
Kleb, William L.; Wood, William A.
2004-01-01
The computational simulation community is not routinely publishing independently verifiable tests to accompany new models or algorithms. A survey reveals that only 22% of new models published are accompanied by tests suitable for independently verifying the new model. As the community develops larger codes with increased functionality, and hence increased complexity in terms of the number of building block components and their interactions, it becomes prohibitively expensive for each development group to derive the appropriate tests for each component. Therefore, the computational simulation community is building its collective castle on a very shaky foundation of components with unpublished and unrepeatable verification tests. The computational simulation community needs to begin publishing component level verification tests before the tide of complexity undermines its foundation.
Consortium for Verification Technology Fellowship Report.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sadler, Lorraine E.
2017-06-01
As one recipient of the Consortium for Verification Technology (CVT) Fellowship, I spent eight days as a visiting scientist at the University of Michigan, Department of Nuclear Engineering and Radiological Sciences (NERS). During this time, I participated in multiple department and research group meetings and presentations, met with individual faculty and students, toured multiple laboratories, and taught one-half of a one-unit class on Risk Analysis in Nuclear Arms control (six 1.5 hour lectures). The following report describes some of the interactions that I had during my time as well as a brief discussion of the impact of this fellowship onmore » members of the consortium and on me/my laboratory’s technical knowledge and network.« less
Documentation requirements for Applications Systems Verification and Transfer projects (ASVTs)
NASA Technical Reports Server (NTRS)
Suchy, J. T.
1977-01-01
NASA's Application Systems Verification and Transfer Projects (ASVTs) are deliberate efforts to facilitate the transfer of applications of NASA-developed space technology to users such as federal agencies, state and local governments, regional planning groups, public service institutions, and private industry. This study focused on the role of documentation in facilitating technology transfer both to primary users identified during project planning and to others with similar information needs. It was understood that documentation can be used effectively when it is combined with informal (primarily verbal) communication within each user community and with other formal techniques such as organized demonstrations and training programs. Documentation examples from eight ASVT projects and one potential project were examined to give scope to the investigation.
Rosso, Osvaldo A; Ospina, Raydonal; Frery, Alejandro C
2016-01-01
We present a new approach for handwritten signature classification and verification based on descriptors stemming from time causal information theory. The proposal uses the Shannon entropy, the statistical complexity, and the Fisher information evaluated over the Bandt and Pompe symbolization of the horizontal and vertical coordinates of signatures. These six features are easy and fast to compute, and they are the input to an One-Class Support Vector Machine classifier. The results are better than state-of-the-art online techniques that employ higher-dimensional feature spaces which often require specialized software and hardware. We assess the consistency of our proposal with respect to the size of the training sample, and we also use it to classify the signatures into meaningful groups.
In vivo TLD dose measurements in catheter-based high-dose-rate brachytherapy.
Adlienė, Diana; Jakštas, Karolis; Urbonavičius, Benas Gabrielis
2015-07-01
Routine in vivo dosimetry is well established in external beam radiotherapy; however, it is restricted mainly to detection of gross errors in high-dose-rate (HDR) brachytherapy due to complicated measurements in the field of steep dose gradients in the vicinity of radioactive source and high uncertainties. The results of in vivo dose measurements using TLD 100 mini rods and TLD 'pin worms' in catheter-based HDR brachytherapy are provided in this paper alongside with their comparison with corresponding dose values obtained using calculation algorithm of the treatment planning system. Possibility to perform independent verification of treatment delivery in HDR brachytherapy using TLDs is discussed. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Electrical isolation and characteristics of permanent magnet-actuated valves for PDMS microfluidics.
Chen, Chang-Yu; Chen, Chang-Hung; Tu, Ting-Yuan; Lin, Cheng-Ming; Wo, Andrew M
2011-02-21
This paper presents a magnetically driven valve via a permanent magnet pressing a spacer against deformable polydimethylsiloxane (PDMS) to fully close a microchannel. Its ability for electrical isolation, time response, and resistance to backpressure are interrogated. Simulation of the valve closing process was commenced along with experimental verification. Effects of PDMS thickness, and dimension and aspect ratio of microchannels were characterized. Up to 10 GΩ electrical isolation was demonstrated, as well as 50-70 ms valve response and ∼200 kPa resistible pressure. On-demand actuation for arbitrary flow patterns further quantifies its utility. With advantages of simple fabrication, flexible valving location, and no external power requirement, the on/off valve could be leveraged for proof-of-concept microfluidic devices and other applications.
NASA Technical Reports Server (NTRS)
Kleb, W. L.
1994-01-01
Steady flow over the leading portion of a multicomponent airfoil section is studied using computational fluid dynamics (CFD) employing an unstructured grid. To simplify the problem, only the inviscid terms are retained from the Reynolds-averaged Navier-Stokes equations - leaving the Euler equations. The algorithm is derived using the finite-volume approach, incorporating explicit time-marching of the unsteady Euler equations to a time-asymptotic, steady-state solution. The inviscid fluxes are obtained through either of two approximate Riemann solvers: Roe's flux difference splitting or van Leer's flux vector splitting. Results are presented which contrast the solutions given by the two flux functions as a function of Mach number and grid resolution. Additional information is presented concerning code verification techniques, flow recirculation regions, convergence histories, and computational resources.
NASA Astrophysics Data System (ADS)
Gendreau, Keith; Arzoumanian, Zaven; NICER Team
2017-01-01
The Neutron star Interior Composition Explorer (NICER) Mission of Opportunity will fly to the International Space Station (ISS) in 2017 aboard a SpaceX resupply vehicle. Once installed as an external attached payload, NICER will provide an unprecedented soft X-ray timing spectroscopy capability for neutron stars and other phenomena. In June 2016, the NICER payload was delivered from NASA Goddard Space Flight Center to Cape Canaveral to await launch processing. We present measurements made as part of NICER's preship testing to verify performance of its X-ray Timing Instrument and associated subsystems; these measurements demonstrate that NICER meets or surpasses its design requirements in the areas of photon time-tagging resolution, energy resolution, effective collecting area, and high-rate throughput.
Weppner, Justin
2013-08-01
The military medical community has promoted use of Foley catheter balloon tamponade in the initial management of vascular injury owing to neck or maxillofacial trauma. The aim of the study was to compare outcomes with Foley catheter tamponade with those obtained with traditional use of external pressure. This retrospective cohort study evaluated all cases of persistent bleeding caused by penetrating neck or maxillofacial trauma received at one forward aid station between December 2009 and October 2011. Cohorts included those who were treated with Foley catheter tamponade and those managed with external pressure. Which treatment option was applied depended solely on the availability of Foley catheters at the time. The effectiveness of each technique in controlling initial and delayed hemorrhage is described, and the impact on mortality is analyzed using the Student's t test and Fisher's exact test. Seventy-seven subjects met the inclusion criteria with 42 subjects in the Foley group and 35 subjects in the external pressure group. A statistically significant difference was found between the groups regarding delayed failure, experienced by three patients (7%) in the Foley group and nine patients (26%) in the external pressure group (p < 0.05). The difference in mortality, 5% (two patients) in the Foley tamponade group and 23% (eight patients) in the external pressure group, was statistically significant (p < 0.05). For penetrating neck and maxillofacial injuries in a combat environment, Foley catheter balloon tamponade significantly reduced mortality when compared with direct pressure techniques through its effect on preventing delayed bleeding.
40 CFR 1065.920 - PEMS calibrations and verifications.
Code of Federal Regulations, 2014 CFR
2014-07-01
....920 PEMS calibrations and verifications. (a) Subsystem calibrations and verifications. Use all the... verifications and analysis. It may also be necessary to limit the range of conditions under which the PEMS can... additional information or analysis to support your conclusions. (b) Overall verification. This paragraph (b...
This ETV program generic verification protocol was prepared and reviewed for the Verification of Pesticide Drift Reduction Technologies project. The protocol provides a detailed methodology for conducting and reporting results from a verification test of pesticide drift reductio...
NASA Astrophysics Data System (ADS)
Brekke, Stewart
2010-03-01
Every mass or mass group, from atoms and molecules to stars and galaxies,has no motion, is vibrating, rotating,or moving linearly, singularly or in some combination. When created, the excess energy of creation will generate a vibration, rotation and/or linear motion besides the mass or mass group. Curvilinear or orbital motion is linear motion in an external force field. External forces, such as photon, molecular or stellar collisions may over time modify the inital rotational, vibratory or linear motions of the mass of mass group. The energy equation for each mass or mass group is E=mc^2 + 1/2mv^2 + 1/2I2̂+ 1/2kx0^2 + WG+ WE+ WM.
The Development and Implementation of a Dental School Strategic Plan.
ERIC Educational Resources Information Center
Moreland, Ernest F.; And Others
1990-01-01
The University of Maryland Dental School began a comprehensive external and internal analysis of dentistry and dental education. Three analysis groups were established to review the external environment, the competitive environment, and institutional strengths and weaknesses. A strategic directions group identified directions and created a…
A novel approach to EPID-based 3D volumetric dosimetry for IMRT and VMAT QA
NASA Astrophysics Data System (ADS)
Alhazmi, Abdulaziz; Gianoli, Chiara; Neppl, Sebastian; Martins, Juliana; Veloza, Stella; Podesta, Mark; Verhaegen, Frank; Reiner, Michael; Belka, Claus; Parodi, Katia
2018-06-01
Intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) are relatively complex treatment delivery techniques and require quality assurance (QA) procedures. Pre-treatment dosimetric verification represents a fundamental QA procedure in daily clinical routine in radiation therapy. The purpose of this study is to develop an EPID-based approach to reconstruct a 3D dose distribution as imparted to a virtual cylindrical water phantom to be used for plan-specific pre-treatment dosimetric verification for IMRT and VMAT plans. For each depth, the planar 2D dose distributions acquired in air were back-projected and convolved by depth-specific scatter and attenuation kernels. The kernels were obtained by making use of scatter and attenuation models to iteratively estimate the parameters from a set of reference measurements. The derived parameters served as a look-up table for reconstruction of arbitrary measurements. The summation of the reconstructed 3D dose distributions resulted in the integrated 3D dose distribution of the treatment delivery. The accuracy of the proposed approach was validated in clinical IMRT and VMAT plans by means of gamma evaluation, comparing the reconstructed 3D dose distributions with Octavius measurement. The comparison was carried out using (3%, 3 mm) criteria scoring 99% and 96% passing rates for IMRT and VMAT, respectively. An accuracy comparable to the one of the commercial device for 3D volumetric dosimetry was demonstrated. In addition, five IMRT and five VMAT were validated against the 3D dose calculation performed by the TPS in a water phantom using the same passing rate criteria. The median passing rates within the ten treatment plans was 97.3%, whereas the lowest was 95%. Besides, the reconstructed 3D distribution is obtained without predictions relying on forward dose calculation and without external phantom or dosimetric devices. Thus, the approach provides a fully automated, fast and easy QA procedure for plan-specific pre-treatment dosimetric verification.
Chen, Jin-hong; Wu, Hai-yun; He, Kun-lun; He, Yao; Qin, Yin-he
2010-10-01
To establish and verify the prediction model for ischemic cardiovascular disease (ICVD) among the elderly population who were under the current health care programs. Statistical analysis on data from physical examination, hospitalization of the past years, from questionnaire and telephone interview was carried out in May, 2003. Data was from a hospital which implementing a health care program. Baseline population with a proportion of 4:1 was randomly selected to generate both module group and verification group. Baseline data was induced to make the verification group into regression model of module group and to generate the predictive value. Distinguished ability with area under ROC curve and the predictive veracity were verified through comparing the predictive incidence rate and actual incidence rate of every deciles group by Hosmer-Lemeshow test. Predictive veracity of the prediction model at population level was verified through comparing the predictive 6-year incidence rates of ICVD with actual 6-year accumulative incidence rates of ICVD with error rate calculated. The samples included 2271 males over the age of 65 with 1817 people for modeling population and 454 for verified population. All of the samples were stratified into two layers to establish hierarchical Cox proportional hazard regression model, including one advanced age group (greater than or equal to 75 years old), and another elderly group (less than 75 years old). Data from the statically analysis showed that the risk factors in aged group were age, systolic blood pressure, serum creatinine level, fasting blood glucose level, while protective factor was high density lipoprotein;in advanced age group, the risk factors were body weight index, systolic blood pressure, serum total cholesterol level, serum creatinine level, fasting blood glucose level, while protective factor was HDL-C. The area under the ROC curve (AUC) and 95%CI were 0.723 and 0.687 - 0.759 respectively. Discriminating power was good. All individual predictive ICVD cumulative incidence and actual incidence were analyzed using Hosmer-Lemeshow test, χ(2) = 1.43, P = 0.786, showing that the predictive veracity was good. The stratified Cox Hazards Regression model was used to establish prediction model of the aged male population under a certain health care program. The common prediction factor of the two age groups were: systolic blood pressure, serum creatinine level, fasting blood glucose level and HDL-C. The area under the ROC curve of the verification group was 0.723, showing that the distinguished ability was good and the predict ability at the individual level and at the group level were also satisfactory. It was feasible to using Cox Proportional Hazards Regression Model for predicting the population groups.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brad Oberg
2010-12-31
Builders generally use a 'spec and purchase' business management system (BMS) when implementing energy efficiency. A BMS is the overall operational and organizational systems and strategies that a builder uses to set up and run its company. This type of BMS treats building performance as a simple technology swap (e.g. a tank water heater to a tankless water heater) and typically compartmentalizes energy efficiency within one or two groups in the organization (e.g. purchasing and construction). While certain tools, such as details, checklists, and scopes of work, can assist builders in managing the quality of the construction of higher performancemore » homes, they do nothing to address the underlying operational strategies and issues related to change management that builders face when they make high performance homes a core part of their mission. To achieve the systems integration necessary for attaining 40% + levels of energy efficiency, while capturing the cost tradeoffs, builders must use a 'systems approach' BMS, rather than a 'spec and purchase' BMS. The following attributes are inherent in a systems approach BMS; they are also generally seen in quality management systems (QMS), such as the National Housing Quality Certification program: Cultural and corporate alignment, Clear intent for quality and performance, Increased collaboration across internal and external teams, Better communication practices and systems, Disciplined approach to quality control, Measurement and verification of performance, Continuous feedback and improvement, and Whole house integrated design and specification.« less
30 CFR 250.913 - When must I resubmit Platform Verification Program plans?
Code of Federal Regulations, 2011 CFR
2011-07-01
... CONTINENTAL SHELF Platforms and Structures Platform Verification Program § 250.913 When must I resubmit Platform Verification Program plans? (a) You must resubmit any design verification, fabrication... 30 Mineral Resources 2 2011-07-01 2011-07-01 false When must I resubmit Platform Verification...
30 CFR 250.909 - What is the Platform Verification Program?
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 2 2011-07-01 2011-07-01 false What is the Platform Verification Program? 250... Platforms and Structures Platform Verification Program § 250.909 What is the Platform Verification Program? The Platform Verification Program is the MMS approval process for ensuring that floating platforms...
Study of techniques for redundancy verification without disrupting systems, phases 1-3
NASA Technical Reports Server (NTRS)
1970-01-01
The problem of verifying the operational integrity of redundant equipment and the impact of a requirement for verification on such equipment are considered. Redundant circuits are examined and the characteristics which determine adaptability to verification are identified. Mutually exclusive and exhaustive categories for verification approaches are established. The range of applicability of these techniques is defined in terms of signal characteristics and redundancy features. Verification approaches are discussed and a methodology for the design of redundancy verification is developed. A case study is presented which involves the design of a verification system for a hypothetical communications system. Design criteria for redundant equipment are presented. Recommendations for the development of technological areas pertinent to the goal of increased verification capabilities are given.
Requirement Assurance: A Verification Process
NASA Technical Reports Server (NTRS)
Alexander, Michael G.
2011-01-01
Requirement Assurance is an act of requirement verification which assures the stakeholder or customer that a product requirement has produced its "as realized product" and has been verified with conclusive evidence. Product requirement verification answers the question, "did the product meet the stated specification, performance, or design documentation?". In order to ensure the system was built correctly, the practicing system engineer must verify each product requirement using verification methods of inspection, analysis, demonstration, or test. The products of these methods are the "verification artifacts" or "closure artifacts" which are the objective evidence needed to prove the product requirements meet the verification success criteria. Institutional direction is given to the System Engineer in NPR 7123.1A NASA Systems Engineering Processes and Requirements with regards to the requirement verification process. In response, the verification methodology offered in this report meets both the institutional process and requirement verification best practices.
Investigating Navy Officer Retention Using Data Farming
2015-09-01
runs on Microsoft Access . Contractors from SAG Corporation translated the code into Visual Basic for Applications ( VBA ), bringing several benefits...18 b. Accessions ............................................................. 18 c. Promotions...Strategic Actions Group SEED Simulation Experiments & Efficient Design URL Unrestricted Line VBA Visual Basic for Applications VV&A Verification
40 CFR 86.1845-04 - Manufacturer in-use verification testing requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
... group to determine the equivalent NMOG exhaust emission values for the test vehicle. The equivalent NMOG... AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) General Compliance Provisions for Control of Air Pollution From New and In-Use Light...
40 CFR 86.1845-04 - Manufacturer in-use verification testing requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... group to determine the equivalent NMOG exhaust emission values for the test vehicle. The equivalent NMOG... AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) General Compliance Provisions for Control of Air Pollution From New and In-Use Light...
40 CFR 86.1845-04 - Manufacturer in-use verification testing requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... group to determine the equivalent NMOG exhaust emission values for the test vehicle. The equivalent NMOG... AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) General Compliance Provisions for Control of Air Pollution From New and In-Use Light...
40 CFR 86.1845-04 - Manufacturer in-use verification testing requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... group to determine the equivalent NMOG exhaust emission values for the test vehicle. The equivalent NMOG... AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) General Compliance Provisions for Control of Air Pollution From New and In-Use Light...
ETV works in partnership with recognized standards and testing organizations and stakeholder groups consisting of regulators, buyers, and vendor organizations, with the full participation of individual technology developers. The program evaluates the performance of innovative
Direct and Nondirect Marathon Group Therapy and Internal---External Control
ERIC Educational Resources Information Center
Kilmann, Peter R.
1974-01-01
Investigates whether direct and nondirect therapist techniques within a 23-hour marathon format would differentially induce client shifts in locus of control. The no-treatment control group experienced a significant shift toward externality, while the marathon subjects did not fluctuate significantly from pretherapy to posttherapy. (Author)
Marathon Group: Changes in Perceived Locus of Control
ERIC Educational Resources Information Center
Foulds, Melvin L.; And Others
1974-01-01
Fifteen college students participated in a 24-hour marathon group and responded to the Internal-External Scale immediately before and after the experience. The results disclosed significant positive change at the .001 level in perceived locus of internal-external control of reinforcement expectancies in the direction of increased internality.…
30 CFR 250.909 - What is the Platform Verification Program?
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 2 2010-07-01 2010-07-01 false What is the Platform Verification Program? 250... Verification Program § 250.909 What is the Platform Verification Program? The Platform Verification Program is the MMS approval process for ensuring that floating platforms; platforms of a new or unique design...
Property-driven functional verification technique for high-speed vision system-on-chip processor
NASA Astrophysics Data System (ADS)
Nshunguyimfura, Victor; Yang, Jie; Liu, Liyuan; Wu, Nanjian
2017-04-01
The implementation of functional verification in a fast, reliable, and effective manner is a challenging task in a vision chip verification process. The main reason for this challenge is the stepwise nature of existing functional verification techniques. This vision chip verification complexity is also related to the fact that in most vision chip design cycles, extensive efforts are focused on how to optimize chip metrics such as performance, power, and area. Design functional verification is not explicitly considered at an earlier stage at which the most sound decisions are made. In this paper, we propose a semi-automatic property-driven verification technique. The implementation of all verification components is based on design properties. We introduce a low-dimension property space between the specification space and the implementation space. The aim of this technique is to speed up the verification process for high-performance parallel processing vision chips. Our experimentation results show that the proposed technique can effectively improve the verification effort up to 20% for the complex vision chip design while reducing the simulation and debugging overheads.
Hydrologic data-verification management program plan
Alexander, C.W.
1982-01-01
Data verification refers to the performance of quality control on hydrologic data that have been retrieved from the field and are being prepared for dissemination to water-data users. Water-data users now have access to computerized data files containing unpublished, unverified hydrologic data. Therefore, it is necessary to develop techniques and systems whereby the computer can perform some data-verification functions before the data are stored in user-accessible files. Computerized data-verification routines can be developed for this purpose. A single, unified concept describing master data-verification program using multiple special-purpose subroutines, and a screen file containing verification criteria, can probably be adapted to any type and size of computer-processing system. Some traditional manual-verification procedures can be adapted for computerized verification, but new procedures can also be developed that would take advantage of the powerful statistical tools and data-handling procedures available to the computer. Prototype data-verification systems should be developed for all three data-processing environments as soon as possible. The WATSTORE system probably affords the greatest opportunity for long-range research and testing of new verification subroutines. (USGS)
Foraging at the Edge of Chaos: Internal Clock versus External Forcing
NASA Astrophysics Data System (ADS)
Nicolis, S. C.; Fernández, J.; Pérez-Penichet, C.; Noda, C.; Tejera, F.; Ramos, O.; Sumpter, D. J. T.; Altshuler, E.
2013-06-01
Activity rhythms in animal groups arise both from external changes in the environment, as well as from internal group dynamics. These cycles are reminiscent of physical and chemical systems with quasiperiodic and even chaotic behavior resulting from “autocatalytic” mechanisms. We use nonlinear differential equations to model how the coupling between the self-excitatory interactions of individuals and external forcing can produce four different types of activity rhythms: quasiperiodic, chaotic, phase locked, and displaying over or under shooting. At the transition between quasiperiodic and chaotic regimes, activity cycles are asymmetrical, with rapid activity increases and slower decreases and a phase shift between external forcing and activity. We find similar activity patterns in ant colonies in response to varying temperature during the day. Thus foraging ants operate in a region of quasiperiodicity close to a cascade of transitions leading to chaos. The model suggests that a wide range of temporal structures and irregularities seen in the activity of animal and human groups might be accounted for by the coupling between collectively generated internal clocks and external forcings.
Externalizing disorders: cluster 5 of the proposed meta-structure for DSM-V and ICD-11.
Krueger, R F; South, S C
2009-12-01
The extant major psychiatric classifications DSM-IV and ICD-10 are purportedly atheoretical and largely descriptive. Although this achieves good reliability, the validity of a medical diagnosis is greatly enhanced by an understanding of the etiology. In an attempt to group mental disorders on the basis of etiology, five clusters have been proposed. We consider the validity of the fifth cluster, externalizing disorders, within this proposal. We reviewed the literature in relation to 11 validating criteria proposed by the Study Group of the DSM-V Task Force, in terms of the extent to which these criteria support the idea of a coherent externalizing spectrum of disorders. This cluster distinguishes itself by the central role of disinhibitory personality in mental disorders spread throughout sections of the current classifications, including substance dependence, antisocial personality disorder and conduct disorder. Shared biomarkers, co-morbidity and course offer additional evidence for a valid cluster of externalizing disorders. Externalizing disorders meet many of the salient criteria proposed by the Study Group of the DSM-V Task Force to suggest a classification cluster.
Group discriminatory power of handwritten characters
NASA Astrophysics Data System (ADS)
Tomai, Catalin I.; Kshirsagar, Devika M.; Srihari, Sargur N.
2003-12-01
Using handwritten characters we address two questions (i) what is the group identification performance of different alphabets (upper and lower case) and (ii) what are the best characters for the verification task (same writer/different writer discrimination) knowing demographic information about the writer such as ethnicity, age or sex. The Bhattacharya distance is used to rank different characters by their group discriminatory power and the k-nn classifier to measure the individual performance of characters for group identification. Given the tasks of identifying the correct gender/age/ethnicity or handedness, the accumulated performance of characters varies between 65% and 85%.
Hussein, Mohammad; Clementel, Enrico; Eaton, David J; Greer, Peter B; Haworth, Annette; Ishikura, Satoshi; Kry, Stephen F; Lehmann, Joerg; Lye, Jessica; Monti, Angelo F; Nakamura, Mitsuhiro; Hurkmans, Coen; Clark, Catharine H
2017-12-01
Quality assurance (QA) for clinical trials is important. Lack of compliance can affect trial outcome. Clinical trial QA groups have different methods of dose distribution verification and analysis, all with the ultimate aim of ensuring trial compliance. The aim of this study was to gain a better understanding of different processes to inform future dosimetry audit reciprocity. Six clinical trial QA groups participated. Intensity modulated treatment plans were generated for three different cases. A range of 17 virtual 'measurements' were generated by introducing a variety of simulated perturbations (such as MLC position deviations, dose differences, gantry rotation errors, Gaussian noise) to three different treatment plan cases. Participants were blinded to the 'measured' data details. Each group analysed the datasets using their own gamma index (γ) technique and using standardised parameters for passing criteria, lower dose threshold, γ normalisation and global γ. For the same virtual 'measured' datasets, different results were observed using local techniques. For the standardised γ, differences in the percentage of points passing with γ < 1 were also found, however these differences were less pronounced than for each clinical trial QA group's analysis. These variations may be due to different software implementations of γ. This virtual dosimetry audit has been an informative step in understanding differences in the verification of measured dose distributions between different clinical trial QA groups. This work lays the foundations for audit reciprocity between groups, particularly with more clinical trials being open to international recruitment. Copyright © 2017 Elsevier B.V. All rights reserved.
Anchieta, Rodolfo B; Machado, Lucas S; Hirata, Ronaldo; Coelho, Paulo G; Bonfante, Estevam A
2016-10-01
This study evaluated the probability of survival (reliability) of platform-switched fixed dental prostheses (FDPs) cemented on different implant-abutment connection designs. Eighty-four-three-unit FDPs (molar pontic) were cemented on abutments connected to two implants of external or internal hexagon connection. Four groups (n = 21 each) were established: external hexagon connection and regular platform (ERC); external hexagon connection and switched platform (ESC); internal hexagon and regular platform (IRC); and internal hexagon and switched platform (ISC). Prostheses were subjected to step-stress accelerated life testing in water. Weibull curves and probability of survival for a mission of 100,000 cycles at 400 N (two-sided 90% CI) were calculated. The beta values of 0.22, 0.48, 0.50, and 1.25 for groups ERC, ESC, IRC, and ISC, respectively, indicated a limited role of fatigue in damage accumulation, except for group ISC. Survival decreased for both platform-switched groups (ESC: 74%, and ISC: 59%) compared with the regular matching platform counterparts (ERC: 95%, and IRC: 98%). Characteristic strength was higher only for ERC compared with ESC, but not different between internal connections. Failures chiefly involved the abutment screw. Platform switching decreased the probability of survival of FDPs on both external and internal connections. The absence in loss of characteristic strength observed in internal hexagon connections favor their use compared with platform-switched external hexagon connections. © 2016 Eur J Oral Sci.
Tuda, Midori
2008-04-01
A new species, Bruchidius paicus (Insecta, Coleoptera) reared from the seeds of a leguminous tree, Albizia lebbeck (Fabaceae: Mimosoideae: Ingeae), is described from Northern Thailand. Inspection of genital and external morphological traits of B. paicus revealed that the new species belongs to Bruchidius Group 5 (sensu ). The definition of Group 5 is reviewed based on both external and genital morphology. Further comparison of the group to molecular Clade I of Bruchidius (sensu ) indicates the two groups correspond to each other.
Preschool children with externalizing behaviors: experience of fathers and mothers.
Baker, B L; Heller, T L
1996-08-01
Childhood behavior disorders are related to family stress and maladjustment. Little is known, however, about the adjustment of families with preschool-aged children at risk for subsequent behavior disorders. Moreover, fathers' perceptions of child problem behavior and their reactions to it generally have been neglected. Subjects were mothers and fathers of 52 preschool-aged children assigned to one of three groups: control, moderate externalizing, and high externalizing. Higher child externalizing behavior was associated with greater negative family impact, lowered parenting sense of efficacy, and child-rearing practices that were more authoritarian and less authoritative. Mothers and fathers did not differ in actual perceived level of child behavior problems, although both believed that mothers saw more problems. Child Group x Parent interactions indicated that mothers experienced increased stress and a need for help with moderate as well as high child externalizing behaviors, whereas fathers were not elevated on these measures unless the child's externalizing behaviors were high. Implications of these findings for early family intervention are considered.
NASA Technical Reports Server (NTRS)
Underwood, Steve; Lvovsky, Oleg
2007-01-01
The International Space Station (ISS has Qualification and Acceptance Environmental Test Requirements document, SSP 41172 that includes many environmental tests such as Thermal vacuum & Cycling, Depress/Repress, Sinusoidal, Random, and Acoustic Vibration, Pyro Shock, Acceleration, Humidity, Pressure, Electromatic Interference (EMI)/Electromagnetic Compatibility (EMCO), etc. This document also includes (13) leak test methods for Pressure Integrity Verification of the ISS Elements, Systems, and Components. These leak test methods are well known, however, the test procedure for specific leak test method shall be written and implemented paying attention to the important procedural steps/details that, if omitted or deviated, could impact the quality of the final product and affect the crew safety. Such procedural steps/details for different methods include, but not limited to: - Sequence of testing, f or example, pressurization and submersion steps for Method I (Immersion); - Stabilization of the mass spectrometer leak detector outputs fo r Method II (vacuum Chamber or Bell jar); - Proper data processing an d taking a conservative approach while making predictions for on-orbit leakage rate for Method III(Pressure Change); - Proper Calibration o f the mass spectrometer leak detector for all the tracer gas (mostly Helium) Methods such as Method V (Detector Probe), Method VI (Hood), Method VII (Tracer Probe), Method VIII(Accumulation); - Usage of visibl ility aides for Method I (Immersion), Method IV (Chemical Indicator), Method XII (Foam/Liquid Application), and Method XIII (Hydrostatic/Visual Inspection); While some methods could be used for the total leaka ge (either internal-to-external or external-to-internal) rate requirement verification (Vacuum Chamber, Pressure Decay, Hood, Accumulation), other methods shall be used only as a pass/fail test for individual joints (e.g., welds, fittings, and plugs) or for troubleshooting purposes (Chemical Indicator, Detector Probe, Tracer Probe, Local Vacuum Chamber, Foam/Liquid Application, and Hydrostatic/Visual Inspection). Any isolation of SSP 41172 requirements have led to either retesting of hardware or accepting a risk associated with the potential system or component pressure integrity problem during flight.
Vredenbregt, M J; Caspers, P W J; Hoogerbrugge, R; Barends, D M
2003-11-01
Recently the CPMP/CVMP sent out for consultation the draft Note for Guidance (dNfG) on the use of near infrared spectroscopy (NIRS) by the pharmaceutical industry and the data to be forwarded in part II of the dossier for a marketing authorization. We explored the practicability of this dNfG with respect to the verification of the correct identity of starting materials in a generic tablet-manufacturing site. Within the boundaries of the dNfG, a release procedure was developed for 12 substances containing structurally related compounds and substances differing only in particle size. For the method development literature data were also taken into consideration. Good results were obtained with wavelength correlation (WC), applied on raw spectra or second derivative spectra both without smoothing. The defined threshold of 0.98 for raw spectra differentiated between all molecular structures. Both methods were found to be robust over a period of 1 year. For the differentiation between the different particle sizes a subsequent second chemometric technique had to be used. Soft independent modelling of class analogy (SIMCA) with a probability level of 0.01 proved suitable. Internal and external validation I according to the dNfG showed no incorrect rejections or false acceptances. External validation II according to the dNfG was carried out with 95 potentially interfering substances from which 46 were tested experimentally. Macrogol 400 was not distinguished from macrogol 300. For the complete verification of the identity of macrogol 300 test A of the European Pharmacopoeia is needed in addition to the NIRS application. A release procedure developed with WC applied on raw spectra and SIMCA as a second method, which is different from the preferred method of the dNfG, was tested in practice with good results. We conclude that the dNfG has good practicability and that deviations from the preferred methods of the dNfG can also give good differentiation.
Cha, Jun-Youl; Kim, Jae-Hak; Hong, Ju; Choi, Young-Tae; Kim, Min-Ho; Cho, Ji-Hyun; Ko, Il-Gyu; Jee, Yong-Seok
2014-02-01
The aim of this study was to investigate the effects of a 12-week rehabilitation program on body composition, shoulder pain, and isokinetic internal/external torques of pitchers with impingement syndrome. A total of 30 pitchers were divided into 2 groups: experimental group (EG, n = 16) and control group (CG, n= 14). The rehabilitation program consisted of physical therapy, warm-up, work-out, and cool-down. As results, body weight and fat mass of EG were decreased whereas muscle mass of EG was significantly increased after the experiment. The pain degrees in resting, normal daily activity, and strenuous activity on the numeric pain rating scale were significantly decreased in the EG. The internal and external peak torques (PTs) of uninvolved and involved sides of EG were increased in EG after 12 weeks. Such results provide a deficit ratio of both sides in EG close to normal values. The ratios of internal/external PTs in EG were also close to the reference values. The internal and external total works of both sides in EG were similar to the values of PT. The fatigue indices of internal and external rotators of both sides in EG were decreased. As a conclusion, a 12-week rehabilitation program reduced the shoulder pain, improved the body composition and enhanced the isokinetic shoulder internal/external rotators in EG with impingement symptoms. Also the study suggested that the rehabilitation program evened out the ratio between internal and external rotators and lowered the fatigue level after the experiment.
Cha, Jun-Youl; Kim, Jae-Hak; Hong, Ju; Choi, Young-Tae; Kim, Min-Ho; Cho, Ji-Hyun; Ko, Il-Gyu; Jee, Yong-Seok
2014-01-01
The aim of this study was to investigate the effects of a 12-week rehabilitation program on body composition, shoulder pain, and isokinetic internal/external torques of pitchers with impingement syndrome. A total of 30 pitchers were divided into 2 groups: experimental group (EG, n = 16) and control group (CG, n= 14). The rehabilitation program consisted of physical therapy, warm-up, work-out, and cool-down. As results, body weight and fat mass of EG were decreased whereas muscle mass of EG was significantly increased after the experiment. The pain degrees in resting, normal daily activity, and strenuous activity on the numeric pain rating scale were significantly decreased in the EG. The internal and external peak torques (PTs) of uninvolved and involved sides of EG were increased in EG after 12 weeks. Such results provide a deficit ratio of both sides in EG close to normal values. The ratios of internal/external PTs in EG were also close to the reference values. The internal and external total works of both sides in EG were similar to the values of PT. The fatigue indices of internal and external rotators of both sides in EG were decreased. As a conclusion, a 12-week rehabilitation program reduced the shoulder pain, improved the body composition and enhanced the isokinetic shoulder internal/external rotators in EG with impingement symptoms. Also the study suggested that the rehabilitation program evened out the ratio between internal and external rotators and lowered the fatigue level after the experiment. PMID:24678503
Austin, John R
2003-10-01
Previous research on transactive memory has found a positive relationship between transactive memory system development and group performance in single project laboratory and ad hoc groups. Closely related research on shared mental models and expertise recognition supports these findings. In this study, the author examined the relationship between transactive memory systems and performance in mature, continuing groups. A group's transactive memory system, measured as a combination of knowledge stock, knowledge specialization, transactive memory consensus, and transactive memory accuracy, is positively related to group goal performance, external group evaluations, and internal group evaluations. The positive relationship with group performance was found to hold for both task and external relationship transactive memory systems.
Canbulat, Nejla; Ayhan, Fatma; Inal, Sevil
2015-02-01
The aim of this study was to investigate the effect of external cold and vibration stimulation via Buzzy on the pain and anxiety level of children during peripheral intravenous (IV) cannulation. This study was a prospective, randomized controlled trial. The sample consisted of 176 children ages 7 to 12 years who were randomly assigned to two groups: a control group that received no peripheral IV cannulation intervention and an experimental group that received external cold and vibration via Buzzy. The same nurse conducted the peripheral IV cannulation in all the children, and the same researcher applied the external cold and vibration to all the children. The external cold and the vibration were applied 1 minute before the peripheral IV cannulation procedure and continued until the end of the procedure. Preprocedural anxiety was assessed using the Children's Fear Scale, along with reports by the children, their parents, and an observer. Procedural anxiety was assessed with the Children's Fear Scale and the parents' and the observer's reports. Procedural pain was assessed using the Wong Baker Faces Scale and the visual analog scale self-reports of the children. Preprocedural anxiety did not differ significantly. Comparison of the two groups showed significantly lower pain and anxiety levels in the experimental group than in the control group during the peripheral IV cannulation. Buzzy can be considered to provide an effective combination of coldness and vibration. This method can be used during pediatric peripheral IV cannulation by pediatric nurses. Copyright © 2015 American Society for Pain Management Nursing. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alvarez, P; Gonzalez, S; McDonald, L
Purpose: Analysis of the performance of the microSTARii reader for optically stimulated luminescence dosimeters (OSLD) used by the IROC Houston Quality Assurance Center (IROC HQAC) for external audits compare to the characteristics of the Microstar reader. Methods: The IROC HQAC uses the Microstar reader for the OSLD program for verification of output of photon, electron and proton beams. The calculation of dose from the OSLD system is based on a group of factors defined at time of the commissioning of a batch of detectors. Factors like system sensitivity (SS), depletion (KD), element correction factor (ECF), linearity (KL), energy correction (KE).more » The new microSTARii unit presents many hardware and software upgrades that were considered useful for this program. Based on these changes many factors, that were considered reader dependent, were revised in order to analyze the effect of the new reading process. The SS, KD, ECF and KL were evaluated and compared with data defined based on reading done on Microstar reader. Results: The SS is reader specific and specified at 100 cGy dose level. This value is define per reading session and monitored over time. The KD factor was found to be different because of reading procedure are different. The ECF values changed for a group of nano dots compare to values defined based on reading done on the Microstar reader. The KL was defined for the reader. Conclusion: The new microSTARii reader presents new features that improve the efficiency of the OSLD program at the IROC HQAC. New characterization is needed before final implementation is done to match the requirements of the existing OSLD system defined for the Microstar reader. Changes in uncertainty of the results has not been analized.« less
In vivo dosimetry in UK external beam radiotherapy: current and future usage.
MacDougall, Niall D; Graveling, Michael; Hansen, Vibeke N; Brownsword, Kevin; Morgan, Andrew
2017-04-01
Towards Safer Radiotherapy recommended that radiotherapy (RT) centres should have protocols in place for in vivo dosimetry (IVD) monitoring at the beginning of patient treatment courses (Donaldson S. Towards safer radiotherapy. R Coll Radiol 2008). This report determines IVD implementation in the UK in 2014, the methods used and makes recommendations on future use. Evidence from peer-reviewed journals was used in conjunction with the first survey of UK RT centre IVD practice since the publication of Towards Safer Radiotherapy. In March 2014, profession-specific questionnaires were sent to radiographer, clinical oncologist and physics staff groups in each of the 66 UK RT centres. Response rates from each group were 74%, 45% and 74%, respectively. 73% of RT centres indicated that they performed IVD. Diodes are the most popular IVD device. Thermoluminescent dosimeter (TLD) is still in use in a number of centres but not as a sole modality, being used in conjunction with diodes and/or electronic portal imaging device (EPID). The use of EPID dosimetry is increasing and is considered of most potential value for both geometric and dosimetric verification. Owing to technological advances, such as electronic data transfer, independent monitor unit checking and daily image-guided radiotherapy, the overall risk of adverse treatment events in RT has been substantially reduced. However, the use of IVD may prevent a serious radiation incident. Point dose IVD is not considered suited to the requirements of verifying advanced RT techniques, leaving EPID dosimetry as the current modality likely to be developed as a future standard. Advances in knowledge: An updated perspective on UK IVD use and provision of professional guidelines for future implementation.
In vivo dosimetry in UK external beam radiotherapy: current and future usage
Graveling, Michael; Hansen, Vibeke N; Brownsword, Kevin; Morgan, Andrew
2017-01-01
Objective: Towards Safer Radiotherapy recommended that radiotherapy (RT) centres should have protocols in place for in vivo dosimetry (IVD) monitoring at the beginning of patient treatment courses (Donaldson S. Towards safer radiotherapy. R Coll Radiol 2008). This report determines IVD implementation in the UK in 2014, the methods used and makes recommendations on future use. Methods: Evidence from peer-reviewed journals was used in conjunction with the first survey of UK RT centre IVD practice since the publication of Towards Safer Radiotherapy. In March 2014, profession-specific questionnaires were sent to radiographer, clinical oncologist and physics staff groups in each of the 66 UK RT centres. Results: Response rates from each group were 74%, 45% and 74%, respectively. 73% of RT centres indicated that they performed IVD. Diodes are the most popular IVD device. Thermoluminescent dosimeter (TLD) is still in use in a number of centres but not as a sole modality, being used in conjunction with diodes and/or electronic portal imaging device (EPID). The use of EPID dosimetry is increasing and is considered of most potential value for both geometric and dosimetric verification. Conclusion: Owing to technological advances, such as electronic data transfer, independent monitor unit checking and daily image-guided radiotherapy, the overall risk of adverse treatment events in RT has been substantially reduced. However, the use of IVD may prevent a serious radiation incident. Point dose IVD is not considered suited to the requirements of verifying advanced RT techniques, leaving EPID dosimetry as the current modality likely to be developed as a future standard. Advances in knowledge: An updated perspective on UK IVD use and provision of professional guidelines for future implementation. PMID:28205452
Janicka, Anna; Spaczyńiski, Robert Z; Kurzawa, Rafał
2015-12-01
The aim of this report is to present data concerning results and complications related to infertility treatment using assisted reproductive technology (ART) and insemination (IUI) in Poland in 2012. The report was prepared by the Fertility and Sterility Special Interest Group of the Polish Gynaecological Society (SPiN PTG), based on individual data provided by fertility clinics. Reporting was voluntary data were not subject to external verification. The report presents the availability and the structure of infertility treatment services, the number of procedures performed, their effectiveness and the most common complications. In 2014, 34 Polish fertility clinics provided information to the report, presenting data from 2012. The total number of reported treatment cycles using ART was 17,116 (incl. 10,714 fresh IVF/ICSI) and 14,727 IUI. The clinical pregnancy rate per cycle was on average 33.7% for fresh IVF/ICSI and 13.3% for IUI. The prevalence of multiple births was 15.7% and 6.2%, in case of IVF/ICSI and IUI methods respectively The most frequent complication in the course of treatment using ART was ovarian hyperstimulation syndrome (OHSS)--severe OHSS constituted 0.68% of all stimulated cycles. The SPiN PTG report shows the average effectiveness and safety of ART and was the only proof of responsibility and due diligence of fertility centres in Poland. However, due to the lack of a central register of fertility clinics, facultative participation in the report as well as incomplete information on pregnancy and delivery rate, the collected data do not reflect the full spectrum of Polish reproductive medicine.
Systematic Model-in-the-Loop Test of Embedded Control Systems
NASA Astrophysics Data System (ADS)
Krupp, Alexander; Müller, Wolfgang
Current model-based development processes offer new opportunities for verification automation, e.g., in automotive development. The duty of functional verification is the detection of design flaws. Current functional verification approaches exhibit a major gap between requirement definition and formal property definition, especially when analog signals are involved. Besides lack of methodical support for natural language formalization, there does not exist a standardized and accepted means for formal property definition as a target for verification planning. This article addresses several shortcomings of embedded system verification. An Enhanced Classification Tree Method is developed based on the established Classification Tree Method for Embeded Systems CTM/ES which applies a hardware verification language to define a verification environment.
ERIC Educational Resources Information Center
Harackiewicz, Judith M.; And Others
1987-01-01
Examined the role of attributions in initial and long-term smoking behavior change. Manipulated the externality of treatment. Subjects receiving nicotine gum were superior to the intrinsic self-help group in initial cessation but were inferior in maintaining abstinence. Subjects in the intrinsic self-help group made fewer external attributions for…
Laudate, Thomas M.; Neargarder, Sandy; Dunne, Tracy E.; Sullivan, Karen D.; Joshi, Pallavi; Gilmore, Grover C.; Riedel, Tatiana M.; Cronin-Golomb, Alice
2011-01-01
External support may improve task performance regardless of an individual’s ability to compensate for cognitive deficits through internally-generated mechanisms. We investigated if performance of a complex, familiar visual search task (the game of bingo) could be enhanced in groups with suboptimal vision by providing external support through manipulation of task stimuli. Participants were 19 younger adults, 14 individuals with probable Alzheimer’s disease (AD), 13 AD-matched healthy adults, 17 non-demented individuals with Parkinson’s disease (PD), and 20 PD-matched healthy adults. We varied stimulus contrast, size, and visual complexity during game play. The externally-supported performance interventions of increased stimulus size and decreased complexity resulted in improvements in performance by all groups. Performance improvement through increased stimulus size and decreased complexity was demonstrated by all groups. AD also obtained benefit from increasing contrast, presumably by compensating for their contrast sensitivity deficit. The general finding of improved performance across healthy and afflicted groups suggests the value of visual support as an easy-to-apply intervention to enhance cognitive performance. PMID:22066941
Treatment of unstable intraarticular fracture of distal radius: POP casting with external fixation.
ur Rahman, Obaid; Khan, Mohammad Qadeem; Rasheed, Haroon; Ahmad, Saleem
2012-04-01
To compare radiological and functional outcome of external fixation and distraction with conservative Plaster of Paris (POP) cast for unstable intra-articular fractures of the distal radius. The study was conducted on 60 patients with unstable intra-articular fracture of distal radius who reported to emergency or outpatient Orthopaedic Surgery department of Benazir Bhutto Hospital, Rawalpindi, between March and August 2007. They were divided into two equal groups: Group A and Group B, treated by Plaster of Paris cast, and external fixation with distraction respectively. The functional outcome in terms of freedom from pain, range of movement, grip power and deformity, and the radiological outcome of radial length, incongruity and radio-ulnar joint position were analysed at three months follow-up using a 3-point scoring scale. In Group A, 1 (3%) patient showed excellent result, 8 (27%) patients good results, 19 (63%) patients fair results and 2 (7%) patients poor result. In Group B, 14 (47%) patients showed excellent results, 11 (37%) patients good results, 4 (13%) patients fair results and 1 (3%) patient poor result. The outcome score of the Group B patients was significantly better compared to the Group A patients (p value < 0.05). External fixation has definite advantages over conventional Plaster of Paris cast in the treatment of unstable intra-articular fractures of distal radius.
2012-01-01
Background To determine impact of intraluminal-left anterior descending shunt to prevent myocardial damage in minimally invasive coronary artery bypass. Methods 38 patients were randomly assigned to external tournique occlusion (n = 19) or intraluminal-left anterior descending shunt group (n = 19). Blood samples for cardiac troponin T were collected at 30 minutes prior to, 6 and 24 hours after surgery. Results One patient in external tournique occlusion and two patients in intraluminal-left anterior descending shunt group were excluded from futher analysis due to preoperative cardiac troponin T level above the 99th-percentile. Postoperatively, each six patients in external tournique occlusion (33.3%) and intraluminal-left anterior descending shunt (35.3%) group were above the 99th-percentile. Two patients from each group (external tournique occlusion group 11.1% vs. intraluminal-left anterior descending shunt group 11.8%) had peak values above 10-% coeficient of variation cutoff (p = 1). There were no significant differences in between both groups at all studied timepoints. Conclusion There was no protective effect of intraluminal shunting on myocardial damage compared to short-term tournique occlusion. It is upon the surgeon's discretion which method may preferrably be used to achieve a bloodless field in grafting of the non-occluded left anterior descending in minimally invasive coronary artery bypass. PMID:22809563
NASA Technical Reports Server (NTRS)
Windley, P. J.
1991-01-01
In this paper we explore the specification and verification of VLSI designs. The paper focuses on abstract specification and verification of functionality using mathematical logic as opposed to low-level boolean equivalence verification such as that done using BDD's and Model Checking. Specification and verification, sometimes called formal methods, is one tool for increasing computer dependability in the face of an exponentially increasing testing effort.
Using SysML for verification and validation planning on the Large Synoptic Survey Telescope (LSST)
NASA Astrophysics Data System (ADS)
Selvy, Brian M.; Claver, Charles; Angeli, George
2014-08-01
This paper provides an overview of the tool, language, and methodology used for Verification and Validation Planning on the Large Synoptic Survey Telescope (LSST) Project. LSST has implemented a Model Based Systems Engineering (MBSE) approach as a means of defining all systems engineering planning and definition activities that have historically been captured in paper documents. Specifically, LSST has adopted the Systems Modeling Language (SysML) standard and is utilizing a software tool called Enterprise Architect, developed by Sparx Systems. Much of the historical use of SysML has focused on the early phases of the project life cycle. Our approach is to extend the advantages of MBSE into later stages of the construction project. This paper details the methodology employed to use the tool to document the verification planning phases, including the extension of the language to accommodate the project's needs. The process includes defining the Verification Plan for each requirement, which in turn consists of a Verification Requirement, Success Criteria, Verification Method(s), Verification Level, and Verification Owner. Each Verification Method for each Requirement is defined as a Verification Activity and mapped into Verification Events, which are collections of activities that can be executed concurrently in an efficient and complementary way. Verification Event dependency and sequences are modeled using Activity Diagrams. The methodology employed also ties in to the Project Management Control System (PMCS), which utilizes Primavera P6 software, mapping each Verification Activity as a step in a planned activity. This approach leads to full traceability from initial Requirement to scheduled, costed, and resource loaded PMCS task-based activities, ensuring all requirements will be verified.
External Communities of Practice and Relational Capital
ERIC Educational Resources Information Center
Dewhurst, Frank W.; Navarro, Juan G. Cegarra
2004-01-01
External communities of practice are groups formed by company clients and employees based on common interests, commitment, mutual trust and collaboration whose members regularly share knowledge and learning. This paper examines how external communities of practice contribute to the creation of relational capital through an empirical investigation…
Verification and Validation of Neural Networks for Aerospace Systems
NASA Technical Reports Server (NTRS)
Mackall, Dale; Nelson, Stacy; Schumman, Johann; Clancy, Daniel (Technical Monitor)
2002-01-01
The Dryden Flight Research Center V&V working group and NASA Ames Research Center Automated Software Engineering (ASE) group collaborated to prepare this report. The purpose is to describe V&V processes and methods for certification of neural networks for aerospace applications, particularly adaptive flight control systems like Intelligent Flight Control Systems (IFCS) that use neural networks. This report is divided into the following two sections: 1) Overview of Adaptive Systems; and 2) V&V Processes/Methods.
Verification and Validation of Neural Networks for Aerospace Systems
NASA Technical Reports Server (NTRS)
Mackall, Dale; Nelson, Stacy; Schumann, Johann
2002-01-01
The Dryden Flight Research Center V&V working group and NASA Ames Research Center Automated Software Engineering (ASE) group collaborated to prepare this report. The purpose is to describe V&V processes and methods for certification of neural networks for aerospace applications, particularly adaptive flight control systems like Intelligent Flight Control Systems (IFCS) that use neural networks. This report is divided into the following two sections: Overview of Adaptive Systems and V&V Processes/Methods.
Robson, Holly; Pilkington, Emma; Evans, Louise; DeLuca, Vincent; Keidel, James L
2017-06-01
Comprehension impairments in Wernicke's aphasia are thought to result from a combination of impaired phonological and semantic processes. However, the relationship between these cognitive processes and language comprehension has only been inferred through offline neuropsychological tasks. This study used ERPs to investigate phonological and semantic processing during online single word comprehension. EEG was recorded in a group of Wernicke's aphasia n=8 and control participants n=10 while performing a word-picture verification task. The N400 and Phonological Mapping Negativity/Phonological Mismatch Negativity (PMN) event-related potential components were investigated as an index of semantic and phonological processing, respectively. Individuals with Wernicke's aphasia displayed reduced and inconsistent N400 and PMN effects in comparison to control participants. Reduced N400 effects in the WA group were simulated in the control group by artificially degrading speech perception. Correlation analyses in the Wernicke's aphasia group found that PMN but not N400 amplitude was associated with behavioural word-picture verification performance. The results confirm impairments at both phonological and semantic stages of comprehension in Wernicke's aphasia. However, reduced N400 responses in Wernicke's aphasia are at least partially attributable to earlier phonological processing impairments. The results provide further support for the traditional model of Wernicke's aphasia which claims a causative link between phonological processing and language comprehension impairments. Copyright © 2017 Elsevier Ltd. All rights reserved.
Music Taste Groups and Problem Behavior.
Mulder, Juul; Bogt, Tom Ter; Raaijmakers, Quinten; Vollebergh, Wilma
2007-04-01
Internalizing and externalizing problems differ by musical tastes. A high school-based sample of 4159 adolescents, representative of Dutch youth aged 12 to 16, reported on their personal and social characteristics, music preferences and social-psychological functioning, measured with the Youth Self-Report (YSR). Cluster analysis on their music preferences revealed six taste groups: Middle-of-the-road (MOR) listeners, Urban fans, Exclusive Rock fans, Rock-Pop fans, Elitists, and Omnivores. A seventh group of musically Low-Involved youth was added. Multivariate analyses revealed that when gender, age, parenting, school, and peer variables were controlled, Omnivores and fans within the Exclusive Rock groups showed relatively high scores on internalizing YSR measures, and social, thought and attention problems. Omnivores, Exclusive Rock, Rock-Pop and Urban fans reported more externalizing problem behavior. Belonging to the MOR group that highly appreciates the most popular, chart-based pop music appears to buffer problem behavior. Music taste group membership uniquely explains variance in both internalizing and externalizing problem behavior.
Sex differences in psychological effects of exercise.
Hülya Aşçı, F
2009-08-01
The purpose of this study was to investigate sex differences in psychological effects of exercise on university students. University students (73 female and 65 male) were randomly assigned to experimental and control groups by equating sex in each group. The experimental group participated in step dance sessions of 50 min per day, 3 days per week for 10 weeks with 60-80% of their heart rate reserves. Throughout the 10-week period, the lecture control group was told not to participate in any organized or structured exercise and participated in a lecture that was about the physiological and psychological benefits of exercise. Self-concept, belief in external control, and trait anxiety of the groups were measured before and after the exercise program. A significant improvement in the psychological variables after the exercise program and more improvement for female exercise participants were expected. Analysis revealed no significant initial differences in self-concept, belief in external control, and trait anxiety between the two groups or between males and females, other than family and moral/ethical self. Repeated measures analysis of variance revealed that exercise led to less belief in external control and significant improvement in physical self and identity dimensions of self-concept for the experimental group compared to the control group. However, there was no significant difference in trait anxiety between the two groups after exercise (p>.05). Analysis also revealed that changes in belief in external control, trait anxiety, and self-concept did not differ with regard to sex. Males and females showed no difference in their improvement on trait anxiety, belief in external control, and most dimensions of self-concept during the 10 weeks. Only changes in personal and physical self throughout 10-week period were different for males and females. Exerciser males improved their personal self and physical self scores more than female exercisers and male and female nonexercisers throughout the 10-week period (p<.05).
Xu, Qi-Fei; Lin, Kui-Ran; Zhao, Dai-Jie; Zhang, Song-Qin; Feng, Sheng-Kai; Li, Chen
2017-03-25
To investigate the application and effect of minimally invasive percutaneous anterior pelvic pubic ramus screw fixation in Tile B fractures. A retrospective review was conducted on 56 patients with posterior pelvic ring injury combined with fractures of anterior pubic and ischiadic ramus treated between May 2010 and August 2015, including 31 males and 25 females with an average age of 36.8 years old ranging from 35 to 65 years old. Based on the Tile classification, there were 13 cases of Tile B1 type, 28 cases of Tile B2 type and 15 cases of Tile B3 type. Among them, 26 patients were treated with sacroiliac screws combined with external fixation (external fixator group) and the other 30 patients underwent sacroiliac screw fixation combined with anterior screw fixation (pubic ramus screw group). Postoperative complications, postoperative ambulation time, fracture healing, blood loss, Majeed pelvic function score and visual analogue scale(VAS) were compared between two groups. Fifty-four patients were followed up from 3 to 24 months with a mean of 12 months. There were no significant difference in the peri-operative bleeding and operation time between two groups( P >0.05). The postoperative activity time and fracture healing time of pubic ramus screw group were shorter than those of the external fixator group, the differences were statistically significant( P <0.05). The Majeed score, VAS score of pubic ramus screw group were higher than those of the external fixator group, the differences were statistically significant( P <0.05). The incidence of postoperative complications of pubic ramus screw was lower than that of the external fixator group, the difference was statistically significant ( P <0.05). Percutaneous iliosacral screws fixation combined with the pubic ramus screw is an effective and safty treatment method to the Tile B pelvic fracture. It has advantages of early ambulation, relief of the pain and few complications.
Ospina, Raydonal; Frery, Alejandro C.
2016-01-01
We present a new approach for handwritten signature classification and verification based on descriptors stemming from time causal information theory. The proposal uses the Shannon entropy, the statistical complexity, and the Fisher information evaluated over the Bandt and Pompe symbolization of the horizontal and vertical coordinates of signatures. These six features are easy and fast to compute, and they are the input to an One-Class Support Vector Machine classifier. The results are better than state-of-the-art online techniques that employ higher-dimensional feature spaces which often require specialized software and hardware. We assess the consistency of our proposal with respect to the size of the training sample, and we also use it to classify the signatures into meaningful groups. PMID:27907014
Local versus general anesthesia for external dacryocystorhinostomy in young patients.
Ciftci, Ferda; Pocan, Sibel; Karadayi, Koray; Gulecek, Oguz
2005-05-01
To compare the effectiveness, complications, and patient acceptance of local anesthesia with general anesthesia in young patients for external dacryocystorhinostomy (DCR). Data were prospectively collected over an 8-year period (1996-2004) on young patients (mean age: 22.64+/-1.71) undergoing external DCR in Gulhane Military Medical Academy. Patients were randomly allocated in two groups: general anesthesia (GA) and local anesthesia (LA). Of the 480 DCR procedures, 182 were performed with general anesthesia (44 bilateral), 298 were performed with local anesthesia (32 bilateral). Visual analogue scales were recorded in the postoperative 2-hour period. Postoperative nausea and vomiting (PONV), epistaxis, length of hospital stay, and intraoperative bleeding were noted. Patients in both groups reported being comfortable during and immediately after surgery. Only 2 patients in the LA group required additional local anesthetic because of pain. Intraoperative bleeding was lower in the LA group. Analgesic requirement and signs of nausea and vomiting in the GA group were higher in the early postoperative period (p<0.05). The incidence of PONV was higher (p<0.05) in the GA group. Postoperative epistaxis was observed in 12 patients in the GA group and just 2 patients in the LA group. Length of hospital stay was 2.29+/-0.46 days in the GA group, and 1.23+/-0.42 days in the LA group (p<0.01). Local anesthesia in DCR is safe and comfortable when proper anatomical approach to nerve blocks is performed correctly. Local anesthesia in young patients undergoing external DCR is a good alternative because it is cost-effective and it eliminates the complications of general anesthesia.
Design for Verification: Enabling Verification of High Dependability Software-Intensive Systems
NASA Technical Reports Server (NTRS)
Mehlitz, Peter C.; Penix, John; Markosian, Lawrence Z.; Koga, Dennis (Technical Monitor)
2003-01-01
Strategies to achieve confidence that high-dependability applications are correctly implemented include testing and automated verification. Testing deals mainly with a limited number of expected execution paths. Verification usually attempts to deal with a larger number of possible execution paths. While the impact of architecture design on testing is well known, its impact on most verification methods is not as well understood. The Design for Verification approach considers verification from the application development perspective, in which system architecture is designed explicitly according to the application's key properties. The D4V-hypothesis is that the same general architecture and design principles that lead to good modularity, extensibility and complexity/functionality ratio can be adapted to overcome some of the constraints on verification tools, such as the production of hand-crafted models and the limits on dynamic and static analysis caused by state space explosion.
Effects of target typicality on categorical search.
Maxfield, Justin T; Stalder, Westri D; Zelinsky, Gregory J
2014-10-01
The role of target typicality in a categorical visual search task was investigated by cueing observers with a target name, followed by a five-item target present/absent search array in which the target images were rated in a pretest to be high, medium, or low in typicality with respect to the basic-level target cue. Contrary to previous work, we found that search guidance was better for high-typicality targets compared to low-typicality targets, as measured by both the proportion of immediate target fixations and the time to fixate the target. Consistent with previous work, we also found an effect of typicality on target verification times, the time between target fixation and the search judgment; as target typicality decreased, verification times increased. To model these typicality effects, we trained Support Vector Machine (SVM) classifiers on the target categories, and tested these on the corresponding specific targets used in the search task. This analysis revealed significant differences in classifier confidence between the high-, medium-, and low-typicality groups, paralleling the behavioral results. Collectively, these findings suggest that target typicality broadly affects both search guidance and verification, and that differences in typicality can be predicted by distance from an SVM classification boundary. © 2014 ARVO.
Munzert, Jörn; Maurer, Heiko; Reiser, Mathias
2014-01-01
The authors examined how varying the content of verbal-motor instructions and requesting an internal versus external focus influenced the kinematics and outcome of a golf putting task. On Day 1, 30 novices performed 120 trials with the instruction to focus attention either on performing a pendulum-like movement (internal) or on the desired ball path (external). After 20 retention trials on Day 2, they performed 20 transfer trials with the opposite instruction. Group differences for retention and a group by block interaction showed that external instruction enhanced movement outcome. Kinematic data indicated that specific instruction content influenced outcomes by eliciting changes in movement execution. Switching from the external to the internal focus instruction resulted in a more pendulum-like movement.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-21
... Shuler and Shane Subler, International Trade Compliance Analysts, to Susan Kuhbach, Director, Office 1... Compliance Analysts, Office 1, to Susan H. Kuhbach, Office Director, AD/CVD Operations, Office 1, entitled..., Office Director, AD/CVD Operations, Office 1, entitled ``Verification Report: Tianjin Pipe (Group...
40 CFR 86.1845-01 - Manufacturer in-use verification testing requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... of test vehicles in the sample comply with the sample size requirements of this section. Any post... vehicles, light-duty trucks, and complete heavy-duty vehicles shall test, or cause to have tested a...) Low mileage testing. [Reserved] (c) High-mileage testing—(1) Test groups. Testing must be conducted...
40 CFR 86.1845-01 - Manufacturer in-use verification testing requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
... of test vehicles in the sample comply with the sample size requirements of this section. Any post... vehicles, light-duty trucks, and complete heavy-duty vehicles shall test, or cause to have tested a...) Low mileage testing. [Reserved] (c) High-mileage testing—(1) Test groups. Testing must be conducted...
40 CFR 86.1845-01 - Manufacturer in-use verification testing requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... of test vehicles in the sample comply with the sample size requirements of this section. Any post... vehicles, light-duty trucks, and complete heavy-duty vehicles shall test, or cause to have tested a...) Low mileage testing. [Reserved] (c) High-mileage testing—(1) Test groups. Testing must be conducted...
40 CFR 86.1845-01 - Manufacturer in-use verification testing requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... of test vehicles in the sample comply with the sample size requirements of this section. Any post... vehicles, light-duty trucks, and complete heavy-duty vehicles shall test, or cause to have tested a...) Low mileage testing. [Reserved] (c) High-mileage testing—(1) Test groups. Testing must be conducted...
UAS Integration in the NAS Project Overview: RTCA SC-228 Plenary DAA Working Group 5
NASA Technical Reports Server (NTRS)
Randall, Debra K.
2014-01-01
The presentation is intended to allow the public to know and understand NASA's plans for integrated test to allow them the opportunity to provide feedback and suggestions. The integrated testing will support verification and validation of the RTCA SC-228 UAS minimum operation performance standard requirements.
49 CFR 383.73 - State procedures.
Code of Federal Regulations, 2011 CFR
2011-10-01
... endorsement knowledge tests; (iv) Allow only a group-specific passenger (P) and school bus (S) endorsement and... verification. (1) Prior to issuing a CLP or a CDL to a person the State must verify the name, date of birth... of issuance of the CLP or CDL. (n) Computer system controls. The State must establish computer system...
49 CFR 383.73 - State procedures.
Code of Federal Regulations, 2012 CFR
2012-10-01
... endorsement knowledge tests; (iv) Allow only a group-specific passenger (P) and school bus (S) endorsement and... verification. (1) Prior to issuing a CLP or a CDL to a person the State must verify the name, date of birth... of issuance of the CLP or CDL. (n) Computer system controls. The State must establish computer system...
NASA Astrophysics Data System (ADS)
Malik, A.; Setiawan, A.; Suhandi, A.; Permanasari, A.; Dirgantara, Y.; Yuniarti, H.; Sapriadil, S.; Hermita, N.
2018-01-01
This study aimed to investigate the improvement to pre-service teacher’s communication skills through Higher Order Thinking Laboratory (HOT Lab) on electric circuit topic. This research used the quasi-experiment method with pretest-posttest control group design. Research subjects were 60 students of Physics Education in UIN Sunan Gunung Djati Bandung. The sample was chosen by random sampling technique. Students’ communication skill data collected using a communication skills test instruments-essays form and observations sheets. The results showed that pre-service teacher communication skills using HOT Lab were higher than verification lab. Student’s communication skills in groups using HOT Lab were not influenced by gender. Communication skills could increase due to HOT Lab based on problems solving that can develop communication through hands-on activities. Therefore, the conclusion of this research shows the application of HOT Lab is more effective than the verification lab to improve communication skills of pre-service teachers in electric circuit topic and gender is not related to a person’s communication skills.
[Tobacco quality analysis of producing areas of Yunnan tobacco using near-infrared (NIR) spectrum].
Wang, Yi; Ma, Xiang; Wen, Ya-Dong; Yu, Chun-Xia; Wang, Luo-Ping; Zhao, Long-Lian; Li, Jun-Hui
2013-01-01
In the present study, tobacco quality analysis of different producing areas was carried out applying spectrum projection and correlation methods. The group of industrial classification data was near-infrared (NIR) spectrum in 2010 year of middle parts of tobacco plant from Hongta Tobacco (Group) Co., Ltd. Twelve hundred seventy six superior tobacco leaf samples were collected from four producing areas, in which three areas from Yuxi, Chuxiong and Zhaotong, in Yunnan province all belong to tobacco varieties of K326 and one area from Dali belongs to tobacco varieties of Hongda. The conclusion showed that when the samples were divided into two parts by the ratio of 2 : 1 randomly as analysis and verification sets, the verification set corresponded with the analysis set applying spectrum projection because their correlation coefficients by the first and second dimensional projection were all above 0.99. At the same time, The study discussed a method to get the quantitative similarity values of different producing areas samples. The similarity values were instructive in tobacco plant planning, quality management, acquisition of raw materials of tobacco and tobacco leaf blending.
SPECS: Secure and Privacy Enhancing Communications Schemes for VANETs
NASA Astrophysics Data System (ADS)
Chim, T. W.; Yiu, S. M.; Hui, L. C. K.; Jiang, Zoe L.; Li, Victor O. K.
Vehicular ad hoc network (VANET) is an emerging type of networks which facilitates vehicles on roads to communicate for driving safety. The basic idea is to allow arbitrary vehicles to broadcast ad hoc messages (e.g. traffic accidents) to other vehicles. However, this raises the concern of security and privacy. Messages should be signed and verified before they are trusted while the real identity of vehicles should not be revealed, but traceable by authorized party. Existing solutions either rely heavily on a tamper-proof hardware device, or cannot satisfy the privacy requirement and do not have an effective message verification scheme. In this paper, we provide a software-based solution which makes use of only two shared secrets to satisfy the privacy requirement and gives lower message overhead and at least 45% higher successful rate than previous solutions in the message verification phase using the bloom filter and the binary search techniques. We also provide the first group communication protocol to allow vehicles to authenticate and securely communicate with others in a group of known vehicles.
Verification of the ages of supercentenarians in the United States: results of a matching study.
Rosenwaike, Ira; Stone, Leslie F
2003-11-01
Unprecedented declines in mortality among the very old have led to the emergence of "true" supercentenarians (persons aged 110 and over). The ages of these individuals have been well-documented in European countries with a history of birth registration, but have not been systematically studied in the United States, which lacks similar documentation and where the inaccuracy of age reporting has been an issue. To verify age, we linked records from the Social Security Administration for close to 700 individuals who died from 1980 to 1999 purportedly at ages 110 and older to records of the U.S. censuses of 1880 and 1900, conducted when these individuals were children. This group was a residual group from an earlier file that was reduced by the SSA after data checks that eliminated incorrect records. The results of the matched records for the residual file indicate that over 90% of the whites were accurately reported as supercentenarians, but only half of the blacks appeared to have attained age 110. The verification of age shows that the United States has more "true" supercentenarians than do other nations.
Learning Experience on Transformer Using HOT Lab for Pre-service Physics Teacher’s
NASA Astrophysics Data System (ADS)
Malik, A.; Setiawan, A.; Suhandi, A.; Permanasari, A.
2017-09-01
This study aimed at investigating pre-service teacher’s critical thinking skills improvement through Higher Order Thinking (HOT) Lab on transformer learning. This research used mix method with the embedded experimental model. Research subjects are 60 students of Physics Education in UIN Sunan Gunung Djati Bandung. The results showed that based on the results of the analysis of practical reports and observation sheet shows students in the experimental group was better in carrying out the practicum and can solve the real problem while the control group was going on the opposite. The critical thinking skills of students applying the HOT Lab were higher than the verification lab. Critical thinking skills could increase due to HOT Lab based problems solving that can develop higher order thinking skills through laboratory activities. Therefore, it was concluded that the application of HOT Lab was more effective than verification lab on improving students’ thinking skills on transformer topic learning. Finally, HOT Lab can be implemented in other subject learning and could be used to improve another higher order thinking skills.
Mathematics Achievement and Anxiety and Their Relation to Internalizing and Externalizing Behaviors
ERIC Educational Resources Information Center
Wu, Sarah S.; Willcutt, Erik G.; Escovar, Emily; Menon, Vinod
2014-01-01
Although behavioral difficulties are well documented in reading disabilities, little is known about the relationship between math ability and internalizing and externalizing behaviors. Here, we use standardized measures to investigate the relation among early math ability, math anxiety, and internalizing and externalizing behaviors in a group of…
Early Adolescent Risk Behavior Outcomes of Childhood Externalizing Behavioral Trajectories
ERIC Educational Resources Information Center
Thompson, Richard; Tabone, Jiyoung Kim; Litrownik, Alan J.; Briggs, Ernestine C.; Hussey, Jon M.; English, Diana J.; Dubowitz, Howard
2011-01-01
Little is known about the early childhood indicators of adolescent risk. The link between trajectories of externalizing behavioral problems and early adolescent risk behavior was examined in a longitudinal sample of 875 child participants in the LONGSCAN studies. Five trajectory groups of children defined by externalizing behavior problems were…
Lin, Giant C; Freitag, Suzanne K; Kocharyan, Armine; Yoon, Michael K; Lefebvre, Daniel R; Bleier, Benjamin S
2016-05-01
The medial rectus muscle (MRM) is the medial boundary to the intraconal space of the orbit, and retraction of the MRM is oftentimes necessary for endoscopic removal of intraconal tumors, e.g., orbital hemangioma. We evaluated each of the reported methods of MRM retraction for endoscopic orbital surgery and quantified the degree of intraconal exposure conferred by each method. Eight orbits from four cadaver heads were dissected. In each orbit, medial orbital decompression was performed and the MRM was retracted by using four previously described techniques: (1) external MRM retraction at the globe insertion point by using vessel loop (external group), (2) transseptal MRM retraction by using vessel loop (transseptal group), (3) transchoanal retraction of the MRM by using vessel loop (choanal group), and (4) transseptal four-handed technique by using double ball retraction by a second surgeon (transseptal double ball group). The length, height, and area of exposure of the medial intraconal space were quantified and compared. The average ± standard deviation (SD) anterior-posterior exposures for the external group, transseptal group, and transseptal double ball group were 17.51 ± 3.39 mm, 16.59 ± 4.16 mm, and 18.0 ± 15.25 mm, respectively. The choanal group provided significantly less exposure (12.39 ± 3.44 mm, p = 0.049) than the other groups. The average ± SD vertical exposures for the transseptal group, choanal group, and transseptal double ball group were 12.53 ± 4.38 mm, 13.05 ± 5.86 mm, and 13.57 ± 3.74 mm, respectively. The external group provided significantly less exposure (4.51 ± 1.56 mm, p = 0.0072) than the other groups. The transseptal and transseptal double ball groups provided the greatest total access by surface area (58.88 ± 26.96 mm(2) and 62.94 ± 34.74 mm(2), respectively) compared with the external and choanal groups (34.82 ± 23.37 mm(2) and 43.10 ± 23.68 mm(2), respectively). Although the transseptal trajectory of MRM retraction was optimal, the difference in total area of exposure between the static vessel loop retraction and the dynamic, four-handed technique with double ball instrument retraction was not significant. Of note, the exposure provided by the choanal technique required the surgeon to work both above and below the muscle. Retraction of the MRM toward the choanae provided the least length of exposure, and external retraction exposed the least height and total area. Transseptal MRM retraction was most favorable and provided the largest endoscopic corridor to the medial intraconal space. A four-handed approach for endoscopic intraconal surgery of the orbit may offer advantages in dynamic adjustments in retraction.
Simulation verification techniques study
NASA Technical Reports Server (NTRS)
Schoonmaker, P. B.; Wenglinski, T. H.
1975-01-01
Results are summarized of the simulation verification techniques study which consisted of two tasks: to develop techniques for simulator hardware checkout and to develop techniques for simulation performance verification (validation). The hardware verification task involved definition of simulation hardware (hardware units and integrated simulator configurations), survey of current hardware self-test techniques, and definition of hardware and software techniques for checkout of simulator subsystems. The performance verification task included definition of simulation performance parameters (and critical performance parameters), definition of methods for establishing standards of performance (sources of reference data or validation), and definition of methods for validating performance. Both major tasks included definition of verification software and assessment of verification data base impact. An annotated bibliography of all documents generated during this study is provided.
The U.S. Environmental Protection Agency created the Environmental Technology Verification Program (ETV) to further environmental protection by accelerating the commercialization of new and innovative technology through independent performance verification and dissemination of in...
National Centers for Environmental Prediction
Products Operational Forecast Graphics Experimental Forecast Graphics Verification and Diagnostics Model PARALLEL/EXPERIMENTAL MODEL FORECAST GRAPHICS OPERATIONAL VERIFICATION / DIAGNOSTICS PARALLEL VERIFICATION Developmental Air Quality Forecasts and Verification Back to Table of Contents 2. PARALLEL/EXPERIMENTAL GRAPHICS
National Centers for Environmental Prediction
Operational Forecast Graphics Experimental Forecast Graphics Verification and Diagnostics Model Configuration /EXPERIMENTAL MODEL FORECAST GRAPHICS OPERATIONAL VERIFICATION / DIAGNOSTICS PARALLEL VERIFICATION / DIAGNOSTICS Developmental Air Quality Forecasts and Verification Back to Table of Contents 2. PARALLEL/EXPERIMENTAL GRAPHICS
HDL to verification logic translator
NASA Technical Reports Server (NTRS)
Gambles, J. W.; Windley, P. J.
1992-01-01
The increasingly higher number of transistors possible in VLSI circuits compounds the difficulty in insuring correct designs. As the number of possible test cases required to exhaustively simulate a circuit design explodes, a better method is required to confirm the absence of design faults. Formal verification methods provide a way to prove, using logic, that a circuit structure correctly implements its specification. Before verification is accepted by VLSI design engineers, the stand alone verification tools that are in use in the research community must be integrated with the CAD tools used by the designers. One problem facing the acceptance of formal verification into circuit design methodology is that the structural circuit descriptions used by the designers are not appropriate for verification work and those required for verification lack some of the features needed for design. We offer a solution to this dilemma: an automatic translation from the designers' HDL models into definitions for the higher-ordered logic (HOL) verification system. The translated definitions become the low level basis of circuit verification which in turn increases the designer's confidence in the correctness of higher level behavioral models.
TH-AB-201-01: A Feasibility Study of Independent Dose Verification for CyberKnife
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sato, A; Noda, T; Keduka, Y
2016-06-15
Purpose: CyberKnife irradiation is composed of tiny-size, multiple and intensity-modulated beams compared to conventional linacs. Few of the publications for Independent dose calculation verification for CyberKnife have been reported. In this study, we evaluated the feasibility of independent dose verification for CyberKnife treatment as Secondary check. Methods: The followings were measured: test plans using some static and single beams, clinical plans in a phantom and using patient’s CT. 75 patient plans were collected from several treatment sites of brain, lung, liver and bone. In the test plans and the phantom plans, a pinpoint ion-chamber measurement was performed to assess dosemore » deviation for a treatment planning system (TPS) and an independent verification program of Simple MU Analysis (SMU). In the clinical plans, dose deviation between the SMU and the TPS was performed. Results: In test plan, the dose deviations were 3.3±4.5%, and 4.1±4.4% for the TPS and the SMU, respectively. In the phantom measurements for the clinical plans, the dose deviations were −0.2±3.6% for the TPS and −2.3±4.8% for the SMU. In the clinical plans using the patient’s CT, the dose deviations were −3.0±2.1% (Mean±1SD). The systematic difference was partially derived from inverse square law and penumbra calculation. Conclusion: The independent dose calculation for CyberKnife shows −3.0±4.2% (Mean±2SD) and our study, the confidence limit was achieved within 5% of the tolerance level from AAPM task group 114 for non-IMRT treatment. Thus, it may be feasible to use independent dose calculation verification for CyberKnife treatment as the secondary check. This research is partially supported by Japan Agency for Medical Research and Development (AMED)« less
SU-F-T-267: A Clarkson-Based Independent Dose Verification for the Helical Tomotherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nagata, H; Juntendo University, Hongo, Tokyo; Hongo, H
2016-06-15
Purpose: There have been few reports for independent dose verification for Tomotherapy. We evaluated the accuracy and the effectiveness of an independent dose verification system for the Tomotherapy. Methods: Simple MU Analysis (SMU, Triangle Product, Ishikawa, Japan) was used as the independent verification system and the system implemented a Clarkson-based dose calculation algorithm using CT image dataset. For dose calculation in the SMU, the Tomotherapy machine-specific dosimetric parameters (TMR, Scp, OAR and MLC transmission factor) were registered as the machine beam data. Dose calculation was performed after Tomotherapy sinogram from DICOM-RT plan information was converted to the information for MUmore » and MLC location at more segmented control points. The performance of the SMU was assessed by a point dose measurement in non-IMRT and IMRT plans (simple target and mock prostate plans). Subsequently, 30 patients’ treatment plans for prostate were compared. Results: From the comparison, dose differences between the SMU and the measurement were within 3% for all cases in non-IMRT plans. In the IMRT plan for the simple target, the differences (Average±1SD) were −0.70±1.10% (SMU vs. TPS), −0.40±0.10% (measurement vs. TPS) and −1.20±1.00% (measurement vs. SMU), respectively. For the mock prostate, the differences were −0.40±0.60% (SMU vs. TPS), −0.50±0.90% (measurement vs. TPS) and −0.90±0.60% (measurement vs. SMU), respectively. For patients’ plans, the difference was −0.50±2.10% (SMU vs. TPS). Conclusion: A Clarkson-based independent dose verification for the Tomotherapy can be clinically available as a secondary check with the similar tolerance level of AAPM Task group 114. This research is partially supported by Japan Agency for Medical Research and Development (AMED)« less
42 CFR 457.380 - Eligibility verification.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 4 2010-10-01 2010-10-01 false Eligibility verification. 457.380 Section 457.380... Requirements: Eligibility, Screening, Applications, and Enrollment § 457.380 Eligibility verification. (a) The... State may establish reasonable eligibility verification mechanisms to promote enrollment of eligible...
The Environmental Technology Verification (ETV) Program was created to facilitate the deployment of innovative or improved environmental technologies through performance verification and dissemination of information. The program�s goal is to further environmental protection by a...
Fulkerson, Regina K.; Micka, John A.; DeWerd, Larry A.
2014-01-01
Purpose: Historically, treatment of malignant surface lesions has been achieved with linear accelerator based electron beams or superficial x-ray beams. Recent developments in the field of brachytherapy now allow for the treatment of surface lesions with specialized conical applicators placed directly on the lesion. Applicators are available for use with high dose rate (HDR) 192Ir sources, as well as electronic brachytherapy sources. Part I of this paper will discuss the applicators used with electronic brachytherapy sources; Part II will discuss those used with HDR 192Ir sources. Although the use of these applicators has gained in popularity, the dosimetric characteristics including depth dose and surface dose distributions have not been independently verified. Additionally, there is no recognized method of output verification for quality assurance procedures with applicators like these. Existing dosimetry protocols available from the AAPM bookend the cross-over characteristics of a traditional brachytherapy source (as described by Task Group 43) being implemented as a low-energy superficial x-ray beam (as described by Task Group 61) as observed with the surface applicators of interest. Methods: This work aims to create a cohesive method of output verification that can be used to determine the dose at the treatment surface as part of a quality assurance/commissioning process for surface applicators used with HDR electronic brachytherapy sources (Part I) and 192Ir sources (Part II). Air-kerma rate measurements for the electronic brachytherapy sources were completed with an Attix Free-Air Chamber, as well as several models of small-volume ionization chambers to obtain an air-kerma rate at the treatment surface for each applicator. Correction factors were calculated using MCNP5 and EGSnrc Monte Carlo codes in order to determine an applicator-specific absorbed dose to water at the treatment surface from the measured air-kerma rate. Additionally, relative dose measurements of the surface dose distributions and characteristic depth dose curves were completed in-phantom. Results: Theoretical dose distributions and depth dose curves were generated for each applicator and agreed well with the measured values. A method of output verification was created that allows users to determine the applicator-specific dose to water at the treatment surface based on a measured air-kerma rate. Conclusions: The novel output verification methods described in this work will reduce uncertainties in dose delivery for treatments with these kinds of surface applicators, ultimately improving patient care. PMID:24506635
ERIC Educational Resources Information Center
Ojiambo, Deborah
2011-01-01
This pilot study investigated the impact of group activity play therapy (GAPT) on displaced orphans aged 10 to 12 years living in a large children's village in Uganda. Teachers and housemothers identified 60 preadolescents exhibiting clinical levels of internalizing and externalizing behavior problems. The participants' ethnicity was African and…
ERIC Educational Resources Information Center
Wiebe, Natasha G.; Maticka-Tyndale, Eleanor
2017-01-01
Obtaining external funding has become increasingly difficult for Canadian researchers in the social sciences and humanities. Our literature review suggests that grant-writing groups and workshops make an important contribution to increasing both applications for external funding and success in funding competitions. This article describes an…
Piñeiro, Bárbara; Díaz, Diana R; Monsalve, Luis M; Martínez, Úrsula; Meade, Cathy D; Meltzer, Lauren R; Brandon, Karen O; Unrod, Marina; Brandon, Thomas H; Simmons, Vani N
2018-01-01
Smoking-related illnesses are the leading causes of death among Hispanics/Latinos. Yet, there are few smoking cessation interventions targeted for this population. The goal of this study was to "transcreate" an existing, previously validated, English language self-help smoking cessation intervention, titled Forever Free ® : Stop Smoking for Good, for Spanish-speaking smokers. Rather than simply translating the materials, our transcreation process involved culturally adapting the intervention to enhance acceptability and receptivity of the information. We utilized a multiphase qualitative approach (focus groups and learner verification interviews) to develop a linguistically and culturally relevant intervention for the diverse sub-ethnic groups of Hispanic/Latino smokers. Focus group findings indicated a need to underscore several additional cultural characteristics and themes such as the need to address familism and unique stressors faced by immigrants and to provide information regarding nicotine replacement therapy. Learner verification findings indicated a need to further emphasize financial and social benefits of quitting smoking and to discuss how family and friends can support the quit attempt. These steps led to the development of a Spanish-language smoking cessation intervention titled, Libre del cigarillo, por mi familia y por mí: Guía para dejar de fumar, that is currently being tested in a national randomized controlled trial.
Mathematics achievement and anxiety and their relation to internalizing and externalizing behaviors.
Wu, Sarah S; Willcutt, Erik G; Escovar, Emily; Menon, Vinod
2014-01-01
Although behavioral difficulties are well documented in reading disabilities, little is known about the relationship between math ability and internalizing and externalizing behaviors. Here, we use standardized measures to investigate the relation among early math ability, math anxiety, and internalizing and externalizing behaviors in a group of 366 second and third graders. Math achievement was significantly correlated with attentional difficulties and social problems but not with internalizing symptoms. The relation between math achievement and externalizing behavioral problems was stronger in girls than in boys. Math achievement was not correlated with trait anxiety but was negatively correlated with math anxiety. Critically, math anxiety differed significantly between children classified as math learning disabled (MLD), low achieving (LA), and typically developing (TD), with math anxiety significantly higher in the MLD and LA groups compared to the TD group. Our findings suggest that, even in nonclinical samples, math difficulties at the earliest stages of formal math learning are associated with attentional difficulties and domain-specific anxiety. These findings underscore the need for further examination of the shared cognitive, neural, and genetic influences underlying problem solving and nonverbal learning difficulties and accompanying internalizing and externalizing behaviors. © Hammill Institute on Disabilities 2013.
Mathematics Achievement and Anxiety and Their Relation to Internalizing and Externalizing Behaviors
Wu, Sarah S.; Willcutt, Erik G.; Escovar, Emily; Menon, Vinod
2013-01-01
Although behavioral difficulties are well documented in reading disabilities, little is known about the relationship between math ability and internalizing and externalizing behaviors. Here, we use standardized measures to investigate the relation among early math ability, math anxiety, and internalizing and externalizing behaviors in a group of 366 second and third graders. Math achievement was significantly correlated with attentional difficulties and social problems but not with internalizing symptoms. The relation between math achievement and externalizing behavioral problems was stronger in girls than in boys. Math achievement was not correlated with trait anxiety but was negatively correlated with math anxiety. Critically, math anxiety differed significantly between children classified as math learning disabled (MLD), low achieving (LA), and typically developing (TD), with math anxiety significantly higher in the MLD and LA groups compared to the TD group. Our findings suggest that, even in nonclinical samples, math difficulties at the earliest stages of formal math learning are associated with attentional difficulties and domain-specific anxiety. These findings underscore the need for further examination of the shared cognitive, neural, and genetic influences underlying problem solving and nonverbal learning difficulties and accompanying internalizing and externalizing behaviors. PMID:23313869
Prosocial Behavior: Long-Term Trajectories and Psychosocial Outcomes.
Flynn, Elinor; Ehrenreich, Samuel E; Beron, Kurt J; Underwood, Marion K
2015-08-01
This study investigated developmental trajectories for prosocial behavior for a sample followed from age 10 - 18 and examined possible adjustment outcomes associated with membership in different trajectory groups. Participants were 136 boys and 148 girls, their teachers, and their parents (19.4% African American, 2.4% Asian, 51.9% Caucasian, 19.5% Hispanic, and 5.8% other). Teachers rated children's prosocial behavior yearly in grades 4 - 12. At the end of the 12 th grade year, teachers, parents, and participants reported externalizing behaviors and participants reported internalizing symptoms, narcissism, and features of borderline personality disorder. Results suggested that prosocial behavior remained stable from middle childhood through late adolescence. Group-based mixture modeling revealed three prosocial trajectory groups: low (18.7%), medium (52.8%), and high (29.6%). Membership in the high prosocial trajectory group predicted lower levels of externalizing behavior as compared to the low prosocial trajectory group, and for girls, lower levels of internalizing symptoms. Membership in the medium prosocial trajectory group also predicted being lower on externalizing behaviors. Membership in the high prosocial trajectory group predicted lower levels of borderline personality features for girls only.
Limb Lengthening and Then Insertion of an Intramedullary Nail: A Case-matched Comparison
Kleinman, Dawn; Fragomen, Austin T.; Ilizarov, Svetlana
2008-01-01
Distraction osteogenesis is an effective method for lengthening, deformity correction, and treatment of nonunions and bone defects. The classic method uses an external fixator for both distraction and consolidation leading to lengthy times in frames and there is a risk of refracture after frame removal. We suggest a new technique: lengthening and then nailing (LATN) technique in which the frame is used for gradual distraction and then a reamed intramedullary nail inserted to support the bone during the consolidation phase, allowing early removal of the external fixator. We performed a retrospective case-matched comparison of patients lengthened with LATN (39 limbs in 27 patients) technique versus the classic (34 limbs in 27 patients). The LATN group wore the external fixator for less time than the classic group (12 versus 29 weeks). The LATN group had a lower external fixation index (0.5 versus 1.9) and a lower bone healing index (0.8 versus 1.9) than the classic group. LATN confers advantages over the classic method including shorter times needed in external fixation, quicker bone healing, and protection against refracture. There are also advantages over the lengthening over a nail and internal lengthening nail techniques. Level of Evidence: Level III, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence. PMID:18800209
Burgos, Jorge; Pijoan, José I; Osuna, Carmen; Cobos, Patricia; Rodriguez, Leire; Centeno, María del Mar; Serna, Rosa; Jimenez, Antonia; Garcia, Eugenia; Fernandez-Llebrez, Luis; Melchor, Juan C
2016-05-01
Our objective was to compare the effect of two pain relief methods (remifentanil vs. nitrous oxide) on the success rate of external cephalic version. We conducted a randomized open label parallel-group controlled single-center clinical trial with sequential design, at Cruces University Hospital, Spain. Singleton pregnancies in noncephalic presentation at term that were referred for external cephalic version were assigned according to a balanced (1:1) restricted randomization scheme to analgesic treatment with remifentanil or nitrous oxide during the procedure. The primary endpoint was external cephalic version success rate. Secondary endpoints were adverse event rate, degree of pain, cesarean rate and perinatal outcomes. The trial was stopped early after the second interim analysis due to a very low likelihood of finding substantial differences in efficacy (futility). The external cephalic version success rate was the same in the two arms (31/60, 51.7%) with 120 women recruited, 60 in each arm. The mean pain score was significantly lower in the remifentanil group (3.2 ± 2.4 vs. 6.0 ± 2.3; p < 0.01). No differences were found in external cephalic version-related complications. There was a trend toward a higher frequency of adverse effects in the remifentanil group (18.3% vs. 6.7%, p = 0.10), with a significantly higher incidence rate (21.7 events/100 women vs. 6.7 events/100 women with nitrous oxide, p = 0.03). All reported adverse events were mild and reversible. Remifentanil for analgesia decreased external cephalic version-related pain but did not increase the success rate of external cephalic version at term and appeared to be associated with an increased frequency of mild adverse effects. © 2016 Nordic Federation of Societies of Obstetrics and Gynecology.
Neuraxial blockade for external cephalic version: a systematic review.
Sultan, P; Carvalho, B
2011-10-01
The desire to decrease the number of cesarean deliveries has renewed interest in external cephalic version. The rationale for using neuraxial blockade to facilitate external cephalic version is to provide abdominal muscular relaxation and reduce patient discomfort during the procedure, so permitting successful repositioning of the fetus to a cephalic presentation. This review systematically examined the current evidence to determine the safety and efficacy of neuraxial anesthesia or analgesia when used for external cephalic version. A systematic literature review of studies that examined success rates of external cephalic version with neuraxial anesthesia was performed. Published articles written in English between 1945 and 2010 were identified using the Medline, Cochrane, EMBASE and Web of Sciences databases. Six, randomized controlled studies were identified. Neuraxial blockade significantly improved the success rate in four of these six studies. A further six non-randomized studies were identified, of which four studies with control groups found that neuraxial blockade increased the success rate of external cephalic version. Despite over 850 patients being included in the 12 studies reviewed, placental abruption was reported in only one patient with a neuraxial block, compared with two in the control groups. The incidence of non-reassuring fetal heart rate requiring cesarean delivery in the anesthesia groups was 0.44% (95% CI 0.15-1.32). Neuraxial blockade improved the likelihood of success during external cephalic version, although the dosing regimen that provides optimal conditions for successful version is unclear. Anesthetic rather than analgesic doses of local anesthetics may improve success. The findings suggest that neuraxial blockade does not compromise maternal or fetal safety during external cephalic version. Crown Copyright © 2011. Published by Elsevier Ltd. All rights reserved.
Hameed, Imran; Riaz, Zahid; Arain, Ghulam A.; Farooq, Omer
2016-01-01
The literature examines the impact of firms' corporate social responsibility (CSR) activities on employees' organizational identification without considering that such activities tend to have different targets. This study explores how perceived external CSR (efforts directed toward external stakeholders) and perceived internal CSR (efforts directed toward employees) activities influence employees' organizational identification. In so doing, it examines the alternative underlying mechanisms through which perceived external and internal CSR activities build employees' identification. Applying the taxonomy prescribed by the group engagement model, the study argues that the effects of perceived external and internal CSR flow through two competing mechanisms: perceived external prestige and perceived internal respect, respectively. Further, it is suggested that calling orientation (how employees see their work contributions) moderates the effects induced by these alternative forms of CSR. The model draws on survey data collected from a sample of 414 employees across five large multinationals in Pakistan. The results obtained using structural equation modeling support these hypotheses, reinforcing the notion that internal and external CSR operate through different mediating mechanisms and more interestingly employees' calling orientation moderates these relationships to a significant degree. Theoretical contributions and practical implications of results are discussed in detail. PMID:27303345
Hameed, Imran; Riaz, Zahid; Arain, Ghulam A; Farooq, Omer
2016-01-01
The literature examines the impact of firms' corporate social responsibility (CSR) activities on employees' organizational identification without considering that such activities tend to have different targets. This study explores how perceived external CSR (efforts directed toward external stakeholders) and perceived internal CSR (efforts directed toward employees) activities influence employees' organizational identification. In so doing, it examines the alternative underlying mechanisms through which perceived external and internal CSR activities build employees' identification. Applying the taxonomy prescribed by the group engagement model, the study argues that the effects of perceived external and internal CSR flow through two competing mechanisms: perceived external prestige and perceived internal respect, respectively. Further, it is suggested that calling orientation (how employees see their work contributions) moderates the effects induced by these alternative forms of CSR. The model draws on survey data collected from a sample of 414 employees across five large multinationals in Pakistan. The results obtained using structural equation modeling support these hypotheses, reinforcing the notion that internal and external CSR operate through different mediating mechanisms and more interestingly employees' calling orientation moderates these relationships to a significant degree. Theoretical contributions and practical implications of results are discussed in detail.
An advanced model of heat and mass transfer in the protective clothing - verification
NASA Astrophysics Data System (ADS)
Łapka, P.; Furmański, P.
2016-09-01
The paper presents an advanced mathematical and numerical models of heat and mass transfer in the multi-layers protective clothing and in elements of the experimental stand subjected to either high surroundings temperature or high radiative heat flux emitted by hot objects. The model included conductive-radiative heat transfer in the hygroscopic porous fabrics and air gaps as well as conductive heat transfer in components of the stand. Additionally, water vapour diffusion in the pores and air spaces as well as phase transition of the bound water in the fabric fibres (sorption and desorption) were accounted for. The thermal radiation was treated in the rigorous way e.g.: semi-transparent absorbing, emitting and scattering fabrics were assumed a non-grey and all optical phenomena at internal or external walls were modelled. The air was assumed transparent. Complex energy and mass balance as well as optical conditions at internal or external interfaces were formulated in order to find exact values of temperatures, vapour densities and radiation intensities at these interfaces. The obtained highly non-linear coupled system of discrete equation was solve by the in-house iterative algorithm which was based on the Finite Volume Method. The model was then successfully partially verified against the results obtained from commercial software for simplified cases.
Reid, J M; Gubitz, G J; Dai, D; Reidy, Y; Christian, C; Counsell, C; Dennis, M; Phillips, S J
2007-12-01
We aimed to validate a previously described six simple variable (SSV) model that was developed from acute and sub-acute stroke patients in our population that included hyper-acute stroke patients. A Stroke Outcome Study enrolled patients from 2001 to 2002. Functional status was assessed at 6 months using the modified Rankin Scale (mRS). SSV model performance was tested in our cohort. 538 acute ischaemic (87%) and haemorrhagic stroke patients were enrolled, 51% of whom presented to hospital within 6 h of symptom recognition. At 6 months post-stroke, 42% of patients had a good outcome (mRS < or = 2). Stroke patients presenting within 6 h of symptom recognition were significantly older with higher stroke severity. In our Stroke Outcome Study dataset, the SSV model had an area under the curve of 0.792 for 6 month outcomes and performed well for hyper-acute or post-acute stroke, age < or > or = 75 years, haemorrhagic or ischaemic stroke, men or women, moderate and severe stroke, but poorly for mild stroke. This study confirms the external validity of the SSV model in our hospital stroke population. This model can therefore be utilised for stratification in acute and hyper-acute stroke trials.
1999-02-11
KENNEDY SPACE CENTER, FLA. -- In the SPACEHAB Facility, the STS-96 crew looks at equipment as part of a payload Interface Verification Test (IVT) for their upcoming mission to the International Space Station . From left are Mission Specialist Ellen Ochoa (behind the opened storage cover ), Commander Kent Rominger, Pilot Rick Husband (holding a lithium hydroxide canister) and Mission Specialists Dan Barry, Valery Tokarev of Russia and Julie Payette. In the background is TTI interpreter Valentina Maydell. The other crew member at KSC for the IVT is Mission Specialist Tamara Jernigan. Mission STS-96 carries the SPACEHAB Logistics Double Module, which has equipment to further outfit the International Space Station service module and equipment that can be off-loaded from the early U.S. assembly flights. The SPACEHAB carries internal logistics and resupply cargo for station outfitting, plus an external Russian cargo crane to be mounted to the exterior of the Russian station segment and used to perform space walking maintenance activities. The double module stowage provides capacity of up to 10,000 lbs. with the ability to accommodate powered payloads, four external rooftop stowage locations, four double-rack locations (two powered), up to 61 bulkhead-mounted middeck locker locations, and floor storage for large unique items and Soft Stowage. STS-96 is targeted to launch May 20 about 9:32 a.m
1999-02-11
KENNEDY SPACE CENTER, FLA. -- In the SPACEHAB Facility, STS-96 Mission Specialist Valery Tokarev of Russia (left) and Commander Kent Rominger (second from right) listen to Lynn Ashby (far right), with JSC, talking about the SPACEHAB equipment in front of them during a payload Interface Verification Test (IVT). In the background behind Tokarev is TTI interpreter Valentina Maydell. Other STS-96 crew members at KSC for the IVT are Pilot Rick Husband and Mission Specialists Dan Barry, Ellen Ochoa, Tamara Jernigan and Julie Payette. Mission STS-96 carries the SPACEHAB Logistics Double Module, which will have equipment to further outfit the International Space Station service module and equipment that can be off-loaded from the early U.S. assembly flights. It carries internal logistics and resupply cargo for station outfitting, plus an external Russian cargo crane to be mounted to the exterior of the Russian station segment and used to perform space walking maintenance activities. The double module stowage provides capacity of up to 10,000 lbs. with the ability to accommodate powered payloads, four external rooftop stowage locations, four double-rack locations (two powered), up to 61 bulkhead-mounted middeck locker locations, and floor storage for large unique items and Soft Stowage. STS-96 is targeted to launch May 20 about 9:32 a.m
1999-02-11
KENNEDY SPACE CENTER, FLA. -- During a payload Interface Verification Test (IVT) in the SPACEHAB Facility, STS-96 Mission Specialist Valery Tokarev of Russia (second from left) and Commander Kent Rominger learn about the Sequential Shunt Unit (SSU) in front of them from Lynn Ashby (far right), with Johnson Space Center. At the far left looking on is TTI interpreter Valentina Maydell. Other crew members at KSC for the IVT are Pilot Rick Husband and Mission Specialists Ellen Ochoa, Tamara Jernigan, Dan Barry and Julie Payette. The SSU is part of the cargo on Mission STS-96, which carries the SPACEHAB Logistics Double Module, with equipment to further outfit the International Space Station service module and equipment that can be off-loaded from the early U.S. assembly flights. The SPACEHAB carries internal logistics and resupply cargo for station outfitting, plus an external Russian cargo crane to be mounted to the exterior of the Russian station segment and used to perform space walking maintenance activities. The double module stowage provides capacity of up to 10,000 lbs. with the ability to accommodate powered payloads, four external rooftop stowage locations, four double-rack locations (two powered), up to 61 bulkhead-mounted middeck locker locations, and floor storage for large unique items and Soft Stowage. STS-96 is targeted to launch May 20 about 9:32 a.m
An experimental study of fault propagation in a jet-engine controller. M.S. Thesis
NASA Technical Reports Server (NTRS)
Choi, Gwan Seung
1990-01-01
An experimental analysis of the impact of transient faults on a microprocessor-based jet engine controller, used in the Boeing 747 and 757 aircrafts is described. A hierarchical simulation environment which allows the injection of transients during run-time and the tracing of their impact is described. Verification of the accuracy of this approach is also provided. A determination of the probability that a transient results in latch, pin or functional errors is made. Given a transient fault, there is approximately an 80 percent chance that there is no impact on the chip. An empirical model to depict the process of error exploration and degeneration in the target system is derived. The model shows that, if no latch errors occur within eight clock cycles, no significant damage is likely to happen. Thus, the overall impact of a transient is well contained. A state transition model is also derived from the measured data, to describe the error propagation characteristics within the chip, and to quantify the impact of transients on the external environment. The model is used to identify and isolate the critical fault propagation paths, the module most sensitive to fault propagation and the module with the highest potential of causing external pin errors.
Eiraldi, Ricardo; Power, Thomas J; Schwartz, Billie S; Keiffer, Jackie N; McCurdy, Barry L; Mathen, Manju; Jawad, Abbas F
2016-07-01
This article presents outcome data of the implementation of three group cognitive-behavioral therapy (GCBT) interventions for children with externalizing behavior problems, anxiety, and depression. School counselors and graduate students co-led the groups in two low-income urban schools. Data were analyzed to assess pre-treatment to post-treatment changes in diagnostic severity level. Results of the exploratory study indicated that all three GCBT protocols were effective at reducing diagnostic severity level for children who had a primary diagnosis of an externalizing disorder, anxiety disorder, or depressive disorder at the clinical or intermediate (at-risk) level. All three GCBT protocols were implemented with relatively high levels of fidelity. Data on the effectiveness of the interventions for reducing diagnostic severity level for externalizing and internalizing spectrum disorders and for specific disorders are presented. A discussion of implementation of mental health evidence-based interventions in urban schools is provided. © The Author(s) 2016.
EPA has created the Environmental Technology Verification Program to facilitate the deployment of innovative or improved environmental technologies through performance verification and dissemination of information. The Air Pollution Control Technology Verification Center, a cente...
40 CFR 1066.240 - Torque transducer verification.
Code of Federal Regulations, 2014 CFR
2014-07-01
... POLLUTION CONTROLS VEHICLE-TESTING PROCEDURES Dynamometer Specifications § 1066.240 Torque transducer verification. Verify torque-measurement systems by performing the verifications described in §§ 1066.270 and... 40 Protection of Environment 33 2014-07-01 2014-07-01 false Torque transducer verification. 1066...
Hatherly, K E; Smylie, J C; Rodger, A; Dally, M J; Davis, S R; Millar, J L
2001-01-01
At the William Buckland Radiotherapy Center (WBRC), field-only electronic portal image (EPI) hard copies are used for radiation treatment field verification for whole brain, breast, chest, spine, and large pelvic fields, as determined by a previous study. A subsequent research project, addressing the quality of double exposed EPI hard copies for sites where field only EPI was not considered adequate to determine field placement, has been undertaken. The double exposed EPI hard copies were compared to conventional double exposed port films for small pelvic, partial brain, and head and neck fields and for a miscellaneous group. All double exposed EPIs were captured during routine clinical procedures using liquid ion chamber cassettes. EPI hard copies were generated using a Visiplex multi-format camera. In sites where port film remained the preferred verification format, the port films were generated as per department protocol. In addition EPIs were collected specifically for this project. Four radiation oncologists performed the evaluation of EPI and port film images independently with a questionnaire completed at each stage of the evaluation process to assess the following: Adequacy of information in the image to assess field placement. Adequacy of information for determining field placement correction. Clinician's preferred choice of imaging for field placement assessment The results indicate that double exposed EPI hard copies generally do containsufficient information to permit evaluation of field placement and can replace conventionaldouble exposed port films in a significant number of sites. These include the following:pelvis fields < 12 X 12 cm, partial brain fields, and a miscellaneous group. However forradical head and neck fields, the preferred verification image format remained port film dueto the image hard copy size and improved contrast for this media. Thus in this departmenthard copy EPI is the preferred modality of field verification for all sites except radical headand neck treatments. This should result in an increase in efficiency of workloadmanagement and patient care.
Göen, Thomas; Schramm, Axel; Baumeister, Thomas; Uter, Wolfgang; Drexler, Hans
2014-08-01
The objective of the study was to investigate how exposure to carbon disulfide (CS2) in a rayon-manufacturing plant has changed within two decades and whether it is possible to calculate valid data for the individual cumulative exposure. The data for CS2 concentration in air and biological exposure monitoring (2-thio-1,3-thiaxolidine-4-carboxylic acid (TTCA) in urine) from two cross-sectional studies, performed in 1992 (n = 362) and 2009 (n = 212) in a German rayon-manufacturing plant, were compared to data obtained from company-internal measurements between the studies. Using the data from the cross-sectional studies and company-internal data, cumulative external exposure and the cumulative internal exposure were calculated for each worker. External and internal CS2 exposure of the employees decreased from 1992 (medians 4.0 ppm and 1.63 mgTTCA/g creatinine) to 2009 (medians 2.5 ppm and 0.86 mg/g). However, company-internal CS2 data do not show a straight trend for this period. The annual medians of the company-internal measurement of external exposure to CS2 have varied between 2.7 and 8.4 ppm, in which median values exceeded 5 ppm generally since 2000. The annual medians for the company-internal biomonitoring assessment ranged between 1.2 and 2.8 mg/g creatinine. The cumulative CS2 exposure ranged from 8.5 to 869.5 ppm years for external exposure and between 1.30 and 176.2 mg/g creatinine years for the internal exposure. Significant correlations were found between the current air pollution and the internal exposure in 2009 but also between the cumulative external and internal CS2 exposure. Current exposure data, usually collected in cross-sectional studies, rarely allow a reliable statement on the cumulative dose, because of higher exposure in the past and of fluctuating courses of exposure. On the other hand, company-internal exposure data may be affected by non-representative measurement strategies. Some verification of the reliability of cumulative exposure data may be possible by testing the correlation between cumulative exposure data of external assessment and biological monitoring.
Mochizuki, Tomoharu; Tanifuji, Osamu; Koga, Yoshio; Hata, Ryosuke; Mori, Takahiro; Nishino, Katsutoshi; Sato, Takashi; Kobayashi, Koichi; Omori, Go; Sakamoto, Makoto; Tanabe, Yuji; Endo, Naoto
2017-05-01
The relative torsional angle of the distal tibia is dependent on a deformity of the proximal tibia, and it is a commonly used torsional parameter to describe deformities of the tibia; however, this parameter cannot show the location and direction of the torsional deformity in the entire tibia. This study aimed to identify the detailed deformity in the entire tibia via a coordinate system based on the diaphysis of the tibia by comparing varus osteoarthritic knees to healthy knees. In total, 61 limbs in 58 healthy subjects (age: 54 ± 18 years) and 55 limbs in 50 varus osteoarthritis (OA) subjects (age: 72 ± 7 years) were evaluated. The original coordinate system based on anatomic points only from the tibial diaphysis was established. The evaluation parameters were 1) the relative torsion in the distal tibia to the proximal tibia, 2) the proximal tibial torsion relative to the tibial diaphysis, and 3) the distal tibial torsion relative to the tibial diaphysis. The relative torsion in the distal tibia to the proximal tibia showed external torsion in both groups, while the external torsion was lower in the OA group than in the healthy group (p < 0.0001). The proximal tibial torsion relative to the tibial diaphysis had a higher external torsion in the OA group (p = 0.012), and the distal tibial torsion relative to the tibial diaphysis had a higher internal torsion in the OA group (p = 0.004) in comparison to the healthy group. The reverse torsional deformity, showing a higher external torsion in the proximal tibia and a higher internal torsion in the distal tibia, occurred independently in the OA group in comparison to the healthy group. Clinically, this finding may prove to be a pathogenic factor in varus osteoarthritic knees. Level Ⅲ. Copyright © 2017 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.
Kim, Johanna Inhyang; Kang, Yun-Hyong; Lee, Jong-Min; Cha, Jungho; Park, Yeong-Hun; Kweon, Kuk-Ju; Kim, Bung-Nyun
2018-06-06
The purpose of this study was to investigate the neural correlates of cognitive-behavioral therapy (CBT) for externalizing behavior problems in perpetrators of school bullying using assessments of brain activity and behavior. Twenty-five adolescent bullies participated in an 8-session intervention. Prior to and after participation, 24 adolescents were evaluated using the Child Behavior Checklist (CBCL) and 23 completed resting-state functional magnetic resonance imaging. Changes in the fractional amplitude of low-frequency fluctuations (fALFF) and scores on the CBCL were analyzed. We also compared the identified changes into 2 groups (low and high delinquency) differentiated by a cutoff of 65 points on the delinquency subscale of the CBCL. Following the intervention, participants exhibited improvement in the subscores of the CBCL and decreases in the fALFF of the inferior parietal lobule, lingual, interior frontal and middle occipital gyrus. A positive correlation was observed between changes in the CBCL externalizing behavior scores and fALFF of the inferior frontal gyrus. The high delinquency group showed a greater decrease in delinquency and externalizing CBCL subscores across time than did the low delinquency group. The high delinquency group had more areas that showed change in fALFF post-intervention than did the low delinquency group. A positive correlation was observed between changes in the CBCL delinquency scores and fALFF of the precentral gyrus in the high delinquency group. The results indicate that this CBT for externalizing behavior problems in bullies had more positive effects on delinquent behavior in adolescents with high levels of delinquency, and these changes were associated with functional changes in brain activity. ClinicalTrials.gov identifier: NCT02670876. Copyright © 2018. Published by Elsevier Inc.
Focus of Attention in Children's Motor Learning: Examining the Role of Age and Working Memory.
Brocken, J E A; Kal, E C; van der Kamp, J
2016-01-01
The authors investigated the relative effectiveness of different attentional focus instructions on motor learning in primary school children. In addition, we explored whether the effect of attentional focus on motor learning was influenced by children's age and verbal working memory capacity. Novice 8-9-year old children (n = 30) and 11-12-year-old children (n = 30) practiced a golf putting task. For each age group, half the participants received instructions to focus (internally) on the swing of their arm, while the other half was instructed to focus (externally) on the swing of the club. Children's verbal working memory capacity was assessed with the Automated Working Memory Assessment. Consistent with many reports on adult's motor learning, children in the external groups demonstrated greater improvements in putting accuracy than children who practiced with an internal focus. This effect was similar across age groups. Verbal working memory capacity was not found to be predictive of motor learning, neither for children in the internal focus groups nor for children in the external focus groups. In conclusion, primary school children's motor learning is enhanced by external focus instructions compared to internal focus instructions. The purported modulatory roles of children's working memory, attentional capacity, or focus preferences require further investigation.
External osteotomy in rhinoplasty: Piezosurgery vs osteotome.
Tirelli, Giancarlo; Tofanelli, Margherita; Bullo, Federica; Bianchi, Max; Robiony, Massimo
2015-01-01
To achieve the desired outcome in rhinoplasty depends on many factors. Osteotomy and surgical reshaping of nasal bones are important steps that require careful planning and execution. The availability of different tools raises the question of which one provides significant advantages for both technique and surgical outcome. Our prospective randomized pilot study compared the outcome of post-traumatic rhinoplasty performed with two different external techniques: ultrasound osteotomic cut using the Piezosurgery Medical Device (Mectron, Carasco, Italy) and traditional external osteotomy. Forty-four lateral osteotomies of the nasal wall were performed in twenty-two patients. In twelve patients the osteotomies were conducted with a 2-mm traditional osteotome (control group), while in the remaining ten patients these were done with the Piezosurgery Medical Device (experimental group). At the postoperative evaluation, significantly lower pain, edema and ecchymosis were noticed in the experimental group (p<0.05). Moreover, the endoscopic evaluation showed fewer mucosal injuries in the experimental group (p<0.05), whereas bleeding, symmetry of the pyramid and presence of external scars, were similar in the two groups. In the present study, Piezosurgery Medical Device allowed for safe lateral osteotomies in rhinoplasty preliminarily demonstrating the potential to reduce some of the most frequent complications of rhinoplasty. Copyright © 2015 Elsevier Inc. All rights reserved.
Experimental verification of layout physical verification of silicon photonics
NASA Astrophysics Data System (ADS)
El Shamy, Raghi S.; Swillam, Mohamed A.
2018-02-01
Silicon photonics have been approved as one of the best platforms for dense integration of photonic integrated circuits (PICs) due to the high refractive index contrast among its materials. Silicon on insulator (SOI) is a widespread photonics technology, which support a variety of devices for lots of applications. As the photonics market is growing, the number of components in the PICs increases which increase the need for an automated physical verification (PV) process. This PV process will assure reliable fabrication of the PICs as it will check both the manufacturability and the reliability of the circuit. However, PV process is challenging in the case of PICs as it requires running an exhaustive electromagnetic (EM) simulations. Our group have recently proposed an empirical closed form models for the directional coupler and the waveguide bends based on the SOI technology. The models have shown a very good agreement with both finite element method (FEM) and finite difference time domain (FDTD) solvers. These models save the huge time of the 3D EM simulations and can be easily included in any electronic design automation (EDA) flow as the equations parameters can be easily extracted from the layout. In this paper we present experimental verification for our previously proposed models. SOI directional couplers with different dimensions have been fabricated using electron beam lithography and measured. The results from the measurements of the fabricate devices have been compared to the derived models and show a very good agreement. Also the matching can reach 100% by calibrating certain parameter in the model.
Science verification of operational aerosol and cloud products for TROPOMI on Sentinel-5 precursor
NASA Astrophysics Data System (ADS)
Lelli, Luca; Gimeno-Garcia, Sebastian; Sanders, Abram; Sneep, Maarten; Rozanov, Vladimir V.; Kokhanvosky, Alexander A.; Loyola, Diego; Burrows, John P.
2016-04-01
With the approaching launch of the Sentinel-5 precursor (S-5P) satellite, scheduled by mid 2016, one preparatory task of the L2 working group (composed by the Institute of Environmental Physics IUP Bremen, the Royal Netherlands Meteorological Institute KNMI De Bilt, and the German Aerospace Center DLR Oberpfaffenhofen) has been the assessment of biases among aerosol and cloud products, that are going to be inferred by the respective algorithms from measurements of the platform's payload TROPOspheric Monitoring Instrument (TROPOMI). The instrument will measure terrestrial radiance with varying moderate spectral resolutions from the ultraviolet throughout the shortwave infrared. Specifically, all the operational and verification algorithms involved in this comparison exploit the sensitivity of molecular oxygen absorption (the A-band, 755-775 nm, with a resolution of 0.54 nm) to changes in optical and geometrical parameters of tropospheric scattering layers. Therefore, aerosol layer height (ALH) and thickness (AOT), cloud top height (CTH), thickness (COT) and albedo (CA) are the targeted properties. First, the verification of these properties has been accomplished upon synchronisation of the respective forward radiative transfer models for a variety of atmospheric scenarios. Then, biases against independent techniques have been evaluated with real measurements of selected GOME-2 orbits. Global seasonal bias assessment has been carried out for CTH, CA and COT, whereas the verification of ALH and AOT is based on the analysis of the ash plume emitted by the icelandic volcanic eruption Eyjafjallajökull in May 2010 and selected dust scenes off the Saharan west coast sensed by SCIAMACHY in year 2009.
Development of an inpatient operational pharmacy productivity model.
Naseman, Ryan W; Lopez, Ben R; Forrey, Ryan A; Weber, Robert J; Kipp, Kris M
2015-02-01
An innovative model for measuring the operational productivity of medication order management in inpatient settings is described. Order verification within a computerized prescriber order-entry system was chosen as the pharmacy workload driver. To account for inherent variability in the tasks involved in processing different types of orders, pharmaceutical products were grouped by class, and each class was assigned a time standard, or "medication complexity weight" reflecting the intensity of pharmacist and technician activities (verification of drug indication, verification of appropriate dosing, adverse-event prevention and monitoring, medication preparation, product checking, product delivery, returns processing, nurse/provider education, and problem-order resolution). The resulting "weighted verifications" (WV) model allows productivity monitoring by job function (pharmacist versus technician) to guide hiring and staffing decisions. A 9-month historical sample of verified medication orders was analyzed using the WV model, and the calculations were compared with values derived from two established models—one based on the Case Mix Index (CMI) and the other based on the proprietary Pharmacy Intensity Score (PIS). Evaluation of Pearson correlation coefficients indicated that values calculated using the WV model were highly correlated with those derived from the CMI-and PIS-based models (r = 0.845 and 0.886, respectively). Relative to the comparator models, the WV model offered the advantage of less period-to-period variability. The WV model yielded productivity data that correlated closely with values calculated using two validated workload management models. The model may be used as an alternative measure of pharmacy operational productivity. Copyright © 2015 by the American Society of Health-System Pharmacists, Inc. All rights reserved.
Earth Sciences annual report, 1987
DOE Office of Scientific and Technical Information (OSTI.GOV)
Younker, L.W.; Donohue, M.L.; Peterson, S.J.
1988-12-01
The Earth Sciences Department at Lawrence Livermore National Laboratory conducts work in support of the Laboratory's energy, defense, and research programs. The Department is organized into ten groups. Five of these -- Nuclear Waste Management, Fossil Energy, Containment, Verification, and Research -- represent major programmatic activities within the Department. Five others -- Experimental Geophysics, Geomechanics, Geology/Geological Engineering, Geochemistry, and Seismology/Applied Geophysics -- are major disciplinary areas that support these and other laboratory programs. This report summarizes work carried out in 1987 by each group and contains a bibliography of their 1987 publications.
Seven Processes that Enable NASA Software Engineering Technologies
NASA Technical Reports Server (NTRS)
Housch, Helen; Godfrey, Sally
2011-01-01
This slide presentation reviews seven processes that NASA uses to ensure that software is developed, acquired and maintained as specified in the NPR 7150.2A requirement. The requirement is to ensure that all software be appraised for the Capability Maturity Model Integration (CMMI). The enumerated processes are: (7) Product Integration, (6) Configuration Management, (5) Verification, (4) Software Assurance, (3) Measurement and Analysis, (2) Requirements Management and (1) Planning & Monitoring. Each of these is described and the group(s) that are responsible is described.
Taylor, Katrina; Seegmiller, Jeffrey; Vella, Chantal A
2016-11-01
To determine whether a decremental protocol could elicit a higher maximal oxygen consumption (VO 2 max) than an incremental protocol in trained participants. A secondary aim was to examine whether cardiac-output (Q) and stroke-volume (SV) responses differed between decremental and incremental protocols in this sample. Nineteen runners/triathletes were randomized to either the decremental or incremental group. All participants completed an initial incremental VO 2 max test on a treadmill, followed by a verification phase. The incremental group completed 2 further incremental tests. The decremental group completed a second VO 2 max test using the decremental protocol, based on their verification phase. The decremental group then completed a final incremental test. During each test, VO 2 , ventilation, and heart rate were measured, and cardiac variables were estimated with thoracic bioimpedance. Repeated-measures analysis of variance was conducted with an alpha level set at .05. There were no significant main effects for group (P = .37) or interaction (P = .10) over time (P = .45). VO 2 max was similar between the incremental (57.29 ± 8.94 mL · kg -1 · min -1 ) and decremental (60.82 ± 8.49 mL · kg -1 · min -1 ) groups over time. Furthermore, Q and SV were similar between the incremental (Q 22.72 ± 5.85 L/min, SV 119.64 ± 33.02 mL/beat) and decremental groups (Q 20.36 ± 4.59 L/min, SV 109.03 ± 24.27 mL/beat) across all 3 trials. The findings suggest that the decremental protocol does not elicit higher VO 2 max than an incremental protocol but may be used as an alternative protocol to measure VO 2 max in runners and triathletes.
48 CFR 4.1302 - Acquisition of approved products and services for personal identity verification.
Code of Federal Regulations, 2010 CFR
2010-10-01
... products and services for personal identity verification. 4.1302 Section 4.1302 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION GENERAL ADMINISTRATIVE MATTERS Personal Identity Verification 4.1302 Acquisition of approved products and services for personal identity verification. (a) In...
48 CFR 4.1302 - Acquisition of approved products and services for personal identity verification.
Code of Federal Regulations, 2012 CFR
2012-10-01
... products and services for personal identity verification. 4.1302 Section 4.1302 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION GENERAL ADMINISTRATIVE MATTERS Personal Identity Verification 4.1302 Acquisition of approved products and services for personal identity verification. (a) In...
48 CFR 4.1302 - Acquisition of approved products and services for personal identity verification.
Code of Federal Regulations, 2011 CFR
2011-10-01
... products and services for personal identity verification. 4.1302 Section 4.1302 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION GENERAL ADMINISTRATIVE MATTERS Personal Identity Verification 4.1302 Acquisition of approved products and services for personal identity verification. (a) In...
48 CFR 4.1302 - Acquisition of approved products and services for personal identity verification.
Code of Federal Regulations, 2013 CFR
2013-10-01
... products and services for personal identity verification. 4.1302 Section 4.1302 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION GENERAL ADMINISTRATIVE MATTERS Personal Identity Verification 4.1302 Acquisition of approved products and services for personal identity verification. (a) In...
48 CFR 4.1302 - Acquisition of approved products and services for personal identity verification.
Code of Federal Regulations, 2014 CFR
2014-10-01
... products and services for personal identity verification. 4.1302 Section 4.1302 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION GENERAL ADMINISTRATIVE MATTERS Personal Identity Verification 4.1302 Acquisition of approved products and services for personal identity verification. (a) In...
Joint ETV/NOWATECH verification protocol for the Sorbisense GSW40 passive sampler
Environmental technology verification (ETV) is an independent (third party) assessment of the performance of a technology or a product for a specified application, under defined conditions and quality assurance. This verification is a joint verification with the US EPA ETV schem...
The U.S. Environmental Protection Agency (EPA) has created the Environmental Technology Verification Program (ETV) to facilitate the deployment of innovative or improved environmental technologies through performance verification and dissemination of information. The goal of the...
Multi-canister overpack project -- verification and validation, MCNP 4A
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goldmann, L.H.
This supporting document contains the software verification and validation (V and V) package used for Phase 2 design of the Spent Nuclear Fuel Multi-Canister Overpack. V and V packages for both ANSYS and MCNP are included. Description of Verification Run(s): This software requires that it be compiled specifically for the machine it is to be used on. Therefore to facilitate ease in the verification process the software automatically runs 25 sample problems to ensure proper installation and compilation. Once the runs are completed the software checks for verification by performing a file comparison on the new output file and themore » old output file. Any differences between any of the files will cause a verification error. Due to the manner in which the verification is completed a verification error does not necessarily indicate a problem. This indicates that a closer look at the output files is needed to determine the cause of the error.« less
Characterization of the a-Si EPID in the unity MR-linac for dosimetric applications.
Torres-Xirau, I; Olaciregui-Ruiz, I; Baldvinsson, G; Mijnheer, B J; van der Heide, U A; Mans, A
2018-01-09
Electronic portal imaging devices (EPIDs) are frequently used in external beam radiation therapy for dose verification purposes. The aim of this study was to investigate the dose-response characteristics of the EPID in the Unity MR-linac (Elekta AB, Stockholm, Sweden) relevant for dosimetric applications under clinical conditions. EPID images and ionization chamber (IC) measurements were used to study the effects of the magnetic field, the scatter generated in the MR housing reaching the EPID, and inhomogeneous attenuation from the MR housing. Dose linearity and dose rate dependencies were also determined. The magnetic field strength at EPID level did not exceed 10 mT, and dose linearity and dose rate dependencies proved to be comparable to that on a conventional linac. Profiles of fields, delivered with and without the magnetic field, were indistinguishable. The EPID center had an offset of 5.6 cm in the longitudinal direction, compared to the beam central axis, meaning that large fields in this direction will partially fall outside the detector area and not be suitable for verification. Beam attenuation by the MRI scanner and the table is gantry angle dependent, presenting a minimum attenuation of 67% relative to the 90° measurement. Repeatability, observed over two months, was within 0.5% (1 SD). In order to use the EPID for dosimetric applications in the MR-linac, challenges related to the EPID position, scatter from the MR housing, and the inhomogeneous, gantry angle-dependent attenuation of the beam will need to be solved.
NASA Astrophysics Data System (ADS)
Miedzinska, Danuta; Boczkowska, Anna; Zubko, Konrad
2010-07-01
In the article a method of numerical verification of experimental results for magnetorheological elastomer samples (MRE) is presented. The samples were shaped into cylinders with diameter of 8 mm and height of 20 mm with various carbonyl iron volume shares (1,5%, 11,5% and 33%). The diameter of soft ferromagnetic substance particles ranged from 6 to 9 μm. During the experiment, initially bended samples were exposed to the magnetic field with intensity levels at 0,1T, 0,3T, 0,5T, 0,7 and 1T. The reaction of the sample to the field action was measured as a displacement of a specimen. Numerical calculation was carried out with the MSC Patran/Marc computer code. For the purpose of numerical analysis the orthotropic material model with the material properties of magnetorheological elastomer along the iron chains, and of the pure elastomer along other directions, was applied. The material properties were obtained from the experimental tests. During the numerical analysis, the initial mechanical load resulting from cylinder deflection was set. Then, the equivalent external force, that was set on the basis of analytical calculations of intermolecular reaction within iron chains in the specific magnetic field, was put on the bended sample. Correspondence of such numerical model with results of the experiment was verified. Similar results of the experiments and both theoretical and FEM analysis indicates that macroscopic modeling of magnetorheological elastomer mechanical properties as orthotropic material delivers accurate enough description of the material's behavior.
Characterization of the a-Si EPID in the unity MR-linac for dosimetric applications
NASA Astrophysics Data System (ADS)
Torres-Xirau, I.; Olaciregui-Ruiz, I.; Baldvinsson, G.; Mijnheer, B. J.; van der Heide, U. A.; Mans, A.
2018-01-01
Electronic portal imaging devices (EPIDs) are frequently used in external beam radiation therapy for dose verification purposes. The aim of this study was to investigate the dose-response characteristics of the EPID in the Unity MR-linac (Elekta AB, Stockholm, Sweden) relevant for dosimetric applications under clinical conditions. EPID images and ionization chamber (IC) measurements were used to study the effects of the magnetic field, the scatter generated in the MR housing reaching the EPID, and inhomogeneous attenuation from the MR housing. Dose linearity and dose rate dependencies were also determined. The magnetic field strength at EPID level did not exceed 10 mT, and dose linearity and dose rate dependencies proved to be comparable to that on a conventional linac. Profiles of fields, delivered with and without the magnetic field, were indistinguishable. The EPID center had an offset of 5.6 cm in the longitudinal direction, compared to the beam central axis, meaning that large fields in this direction will partially fall outside the detector area and not be suitable for verification. Beam attenuation by the MRI scanner and the table is gantry angle dependent, presenting a minimum attenuation of 67% relative to the 90° measurement. Repeatability, observed over two months, was within 0.5% (1 SD). In order to use the EPID for dosimetric applications in the MR-linac, challenges related to the EPID position, scatter from the MR housing, and the inhomogeneous, gantry angle-dependent attenuation of the beam will need to be solved.