NASA Astrophysics Data System (ADS)
Goehring, E. C.; Carlsen, W.; Larsen, J.; Simms, E.; Smith, M.
2007-12-01
From Local to EXtreme Environments (FLEXE) is an innovative new project of the GLOBE Program that involves middle and high school students in systematic, facilitated analyses and comparisons of real environmental data. Through FLEXE, students collect and analyze data from various sources, including the multi-year GLOBE database, deep-sea scientific research projects, and direct measurements of the local environment collected by students using GLOBE sampling protocols. Initial FLEXE materials and training have focused on student understanding of energy transfer through components of the Earth system, including a comparison of how local environmental conditions differ from those found at deep-sea hydrothermal vent communities. While the importance of data acquisition, accuracy and replication is emphasized, FLEXE is also uniquely structured to deepen students' understanding of multiple aspects of the process and nature of science, including written communication of results and on-line peer review. Analyses of data are facilitated through structured, web-based interactions and culminating activities with at-sea scientists through an online forum. The project benefits from the involvement of a professional evaluator, and as the model is tested and refined, it may serve as a template for the inclusion of additional "extreme" earth systems. FLEXE is a partnership of the international GLOBE web- based education program and the NSF Ridge 2000 mid-ocean ridge and hydrothermal vent research program, and includes the expertise of the Center for Science and the Schools at Penn State University. International collaborators also include the InterRidge and ChEss international research programs.
NASA Astrophysics Data System (ADS)
Goehring, L.; Carlsen, W.; Fisher, C. R.; Kerlin, S.; Trautmann, N.; Petersen, W.
2011-12-01
Science education reform since the mid-1990's has called for a "new way of teaching and learning about science that reflects how science itself is done, emphasizing inquiry as a way of achieving knowledge and understanding about the world" (NRC, 1996). Scientists and engineers, experts in inquiry thinking, have been called to help model these practices for students and demonstrate scientific habits of mind. The question, however, is "how best to involve these experts?" given the very real challenges of limited availability of scientists, varying experience with effective pedagogy, widespread geographic distribution of schools, and the sheer number of students involved. Technology offers partial solutions to enable Student-Scientist Interactions (SSI). The FLEXE Project has developed online FLEXE Forums to support efficient, effective SSIs, making use of web-based and database technology to facilitate communication between students and scientists. More importantly, the FLEXE project has approached this question of "how best to do this?" scientifically, combining program evaluation with hypothesis-based research explicitly testing the effects of such SSIs on student learning and attitudes towards science. FLEXE Forums are designed to showcase scientific practices and habits of mind through facilitated interaction between students and scientists. Through these Forums, students "meet" working scientists and learn about their research and the environments in which they work. Scientists provide students with intriguing "real-life" datasets and challenge students to analyze and interpret the data through guiding questions. Students submit their analyses to the Forum, and scientists provide feedback and connect the instructional activity with real-life practice, showcasing their activities in the field. In the FLEXE project, Forums are embedded within inquiry-based instructional units focused on essential learning concepts, and feature the deep-sea environment in contrast to students' local environments to deepen students' understanding of earth systems processes. This presentation will provide an overview of the FLEXE project, a partnership between the Ridge2000 research scientists, science learning researchers, and educators, and will report findings from pilot studies implemented in collaboration with the GLOBE program, a worldwide network of scientists, science educators, and their students. FLEXE Forums have been tested with approximately 1400 students in the US, Germany, Australia and Thailand in 2009, and 1100 students in the US, Thailand, England and Costa Rica in 2010. Description of research methods (e.g., educational hypotheses, assessment of student learning and attitudes through analysis of student writing, and "quick question" surveys) and results will be shared, along with current tests examining the transferability of the approach to other scientists/science educator teams.
NASA Technical Reports Server (NTRS)
Ontiveros, Cordelia
1988-01-01
Various vacuum jacketed cryogenic supply lines at the Shuttle launch site use convoluted flexible expansion joints. The atmosphere at the launch site has a very high salt content, and during a launch, fuel combustion products include hydrochloric acid. This extremely corrosive environment has caused pitting corrosion failure in the flex hoses, which were made of 304L stainless steel. A search was done to find a more corrosion resistant replacement material. This study focused on 19 metal alloys. Tests which were performed include electrochemical corrosion testing, accelerated corrosion testing in a salt fog chamber, long term exposure at the beach corrosion testing site, and pitting corrosion tests in ferric chloride solution. Based on the results of these tests, the most corrosion resistant alloys were found to be (in order) Hastelloy C-22, Inconel 625, Hastelloy C-276, Hastelloy C-4, and Inco Alloy G-3. Of these top five alloys, the Hastelloy C-22 stands out as being the best of those tested for this application.
NASA Technical Reports Server (NTRS)
Macdowell, Louis G., III; Ontiveros, Cordelia
1988-01-01
Various vacuum jacketed cryogenic supply lines at the Shuttle launch site use convoluted flexible expansion joints. The atmosphere at the launch site has a very high salt content, and during a launch fuel combustion products include hydrochloric acid. This extremely corrosive environment has caused pitting corrosion failure in the flex hoses, which were made out of 304L stainless steel. A search was done to find a more corrosion resistant replacement material. Nineteen metal alloys were tested. Tests which were performed include electrochemical corrosion testing, accelerated corrosion testing in a salt fog chamber, long term exposure at the beach corrosion testing site, and pitting corrosion tests in ferric chloride solution. Based on the results, the most corrosion resistant alloys were found to be, in order, Hastelloy C-22, Inconel 625, Hastelloy C-276, Hastelloy C-4, and Inco Alloy G-3. Of these top five alloys, the Hastelloy C-22 stands out as being the best of the alloys tested.
Hofmann, Douglas C.; Polit-Casillas, Raul; Roberts, Scott N.; Borgonia, John-Paul; Dillon, Robert P.; Hilgemann, Evan; Kolodziejska, Joanna; Montemayor, Lauren; Suh, Jong-ook; Hoff, Andrew; Carpenter, Kalind; Parness, Aaron; Johnson, William L.; Kennett, Andrew; Wilcox, Brian
2016-01-01
The use of bulk metallic glasses (BMGs) as the flexspline in strain wave gears (SWGs), also known as harmonic drives, is presented. SWGs are unique, ultra-precision gearboxes that function through the elastic flexing of a thin-walled cup, called a flexspline. The current research demonstrates that BMGs can be cast at extremely low cost relative to machining and can be implemented into SWGs as an alternative to steel. This approach may significantly reduce the cost of SWGs, enabling lower-cost robotics. The attractive properties of BMGs, such as hardness, elastic limit and yield strength, may also be suitable for extreme environment applications in spacecraft. PMID:27883054
NASA Astrophysics Data System (ADS)
Simms, E.; Goehring, E.; Larsen, J.; Kusek, K.
2007-12-01
Sponsored by the National Science Foundation, Ridge 2000 (R2K) is a mid-ocean ridge and hydrothermal vent research program with a history of successful education and public outreach (EPO) programs and products. This presentation will share general science and education partnership strategies and best practices employed by the R2K program, with a particular emphasis on the innovative R2K project From Local to EXtreme Environments (FLEXE). As a new project of the international NSF and NASA sponsored GLOBE earth science education program, FLEXE involves middle and high school students in structured, guided analyses and comparisons of real environmental data. The science and education partnership model employed by FLEXE relies on experienced education coordinators within the R2K and international InterRidge and ChEss science research programs, who directly solicit and facilitate the involvement of an interdisciplinary community of scientists in the project based on their needs and interests. Concurrently, the model also relies on the GLOBE program to facilitate awareness and access to a large, established network of international educators who are interested in the process of science and interacting with the scientific community. The predominantly web-based interfaces that serve to effectively link together the FLEXE science and education communities have been developed by the Center for Science and the Schools at Penn State University, and are based on researched educational pedagogy, tools and techniques. The FLEXE partnership model will be discussed in the context of both broad and specific considerations of audience needs, scientist and educator recruitment, and the costs and benefits for those involved in the project.
Advances in Current Rating Techniques for Flexible Printed Circuits
NASA Technical Reports Server (NTRS)
Hayes, Ron
2014-01-01
Twist Capsule Assemblies are power transfer devices commonly used in spacecraft mechanisms that require electrical signals to be passed across a rotating interface. Flexible printed circuits (flex tapes, see Figure 2) are used to carry the electrical signals in these devices. Determining the current rating for a given trace (conductor) size can be challenging. Because of the thermal conditions present in this environment the most appropriate approach is to assume that the only means by which heat is removed from the trace is thru the conductor itself, so that when the flex tape is long the temperature rise in the trace can be extreme. While this technique represents a worst-case thermal situation that yields conservative current ratings, this conservatism may lead to overly cautious designs when not all traces are used at their full rated capacity. A better understanding of how individual traces behave when they are not all in use is the goal of this research. In the testing done in support of this paper, a representative flex tape used for a flight Solar Array Drive Assembly (SADA) application was tested by energizing individual traces (conductors in the tape) in a vacuum chamber and the temperatures of the tape measured using both fine-gauge thermocouples and infrared thermographic imaging. We find that traditional derating schemes used for bundles of wires do not apply for the configuration tested. We also determine that single active traces located in the center of a flex tape operate at lower temperatures than those on the outside edges.
Comparison of the Ambu AuraFlex with the laryngeal mask airway Flexible: a manikin study.
Sanuki, Takuro; Nakatani, Gosuke; Sugioka, Shingo; Daigo, Erina; Kotani, Junichiro
2011-07-01
The present study compared the Ambu AuraFlex and the laryngeal mask airway (LMA) Flexible with regard to time required for and success rates of insertion on a manikin by dental students who had never used an LMA. In addition, participants' views on ease of insertion of each device were surveyed. Subjects consisted of 30 dental students who inserted each airway device in a manikin. The time required for and success rates of insertion were measured. Subjects were then asked to rate the ease of insertion of each device using the 100-mm visual analog scale (from 0 mm = extremely easy to 100 mm = extremely difficult). Insertion time was shorter with the Ambu AuraFlex (26.6 ± 7.1 seconds) than with the LMA Flexible (30.3 ± 6.8 seconds; P = .045). The rate of successful insertion using the Ambu AuraFlex (28 of 30 attempts, 93.3%) was greater than that with the LMA Flexible (23 of 30 attempts, 76.7%), although the difference was not statistically significant (P = .145). Ambu AuraFlex insertion was considered less difficult (median, 41 mm; 10th to 90th percentiles, 18 to 78 mm) than LMA Flexible insertion (60 mm; 42 to 82 mm; P = .004), as rated using the 100-mm visual analog scale. The Ambu AuraFlex appears to be useful for inexperienced users because it enables quicker and easier insertion than the LMA Flexible. Copyright © 2011 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Safety assessment characteristics of pedestrian legform impactors in vehicle-front impact tests.
Matsui, Yasuhiro
2014-12-01
This study investigated the characteristics of safety assessment results of front-area vehicle impact tests carried out using the Transport Research Laboratory (TRL) legform impactor and a flexible legform impactor (FLEX legform impactor). Different types of vehicles (sedan, sport utility vehicle, high-roof K-car, and light cargo van) were examined. The impact locations in the study were the center of the bumper and an extremely stiff structure of the bumper (i.e., in front of the side member) of each tested vehicle. The measured injury criteria were normalized by injury assessment reference values of each legform impactor. The test results for center and side-member impacts indicated that there were no significant differences in ligament injury assessments derived from the normalized knee ligament injury measures between the TRL legform impactor and the FLEX legform impactor. Evaluations made using the TRL legform impactor and the FLEX legform impactor are thus similar in the vehicle safety investigation for knee ligament injury. Vehicle-center impact test results revealed that the tibia fracture assessments derived from the normalized tibia fracture measures did not significantly differ between the TRL legform impactor and the FLEX legform impactor. However, for an impact against an extremely stiff structure, there was a difference in the tibia fracture assessment between the FLEX legform impactor and the TRL legform impactor owing to their different sensor types. Copyright © 2014 Elsevier Ltd. All rights reserved.
Experimental Charging Behavior of Orion UltraFlex Array Designs
NASA Technical Reports Server (NTRS)
Golofaro, Joel T.; Vayner, Boris V.; Hillard, Grover B.
2010-01-01
The present ground based investigations give the first definitive look describing the charging behavior of Orion UltraFlex arrays in both the Low Earth Orbital (LEO) and geosynchronous (GEO) environments. Note the LEO charging environment also applies to the International Space Station (ISS). The GEO charging environment includes the bounding case for all lunar mission environments. The UltraFlex photovoltaic array technology is targeted to become the sole power system for life support and on-orbit power for the manned Orion Crew Exploration Vehicle (CEV). The purpose of the experimental tests is to gain an understanding of the complex charging behavior to answer some of the basic performance and survivability issues to ascertain if a single UltraFlex array design will be able to cope with the projected worst case LEO and GEO charging environments. Stage 1 LEO plasma testing revealed that all four arrays successfully passed arc threshold bias tests down to -240 V. Stage 2 GEO electron gun charging tests revealed that only the front side area of indium tin oxide coated array designs successfully passed the arc frequency tests
Sood, Aditya; Therattil, Paul J; Russo, Gerardo; Lee, Edward S
2017-01-01
Objective: The latissimus dorsi flap is a workhorse for plastic surgeons, being used for many years for soft-tissue coverage of the upper extremity as well as for functional reconstruction to restore motion to the elbow and shoulder. The authors present a case of functional latissimus dorsi transfer for restoration of elbow flexion and review the literature on technique and outcomes. Methods: A literature review was performed using MEDLINE and the Cochrane Collaboration Library for primary research articles on functional latissimus dorsi flap transfer. Data related to surgical techniques and outcomes were extracted. Results: The literature search yielded 13 relevant studies, with a total of 52 patients who received pedicled, functional latissimus dorsi flaps for upper-extremity reconstruction. The most common etiology requiring reconstruction was closed brachial plexus injury (n = 13). After flap transfer, 98% of patients were able to flex the elbow against gravity and 82.3% were able to flex against resistance. In the presented case, a 77-year-old man underwent resection of myxofibrosarcoma of the upper arm with elbow prosthesis placement and functional latissimus dorsi transfer. The patient was able to actively flex against gravity at 3-month follow-up. Conclusions: A review of the literature shows that nearly all patients undergoing functional latissimus dorsi transfer for upper-extremity reconstruction regain at least motion against gravity whereas a large proportion regain motion against resistance. Considerations when planning for functional latissimus dorsi transfer include patient positioning, appropriate tensioning of the muscle, safe inset, polarity, management of other affected upper-extremity joints, and educating patients on the expected outcomes.
Therattil, Paul J.; Russo, Gerardo; Lee, Edward S.
2017-01-01
Objective: The latissimus dorsi flap is a workhorse for plastic surgeons, being used for many years for soft-tissue coverage of the upper extremity as well as for functional reconstruction to restore motion to the elbow and shoulder. The authors present a case of functional latissimus dorsi transfer for restoration of elbow flexion and review the literature on technique and outcomes. Methods: A literature review was performed using MEDLINE and the Cochrane Collaboration Library for primary research articles on functional latissimus dorsi flap transfer. Data related to surgical techniques and outcomes were extracted. Results: The literature search yielded 13 relevant studies, with a total of 52 patients who received pedicled, functional latissimus dorsi flaps for upper-extremity reconstruction. The most common etiology requiring reconstruction was closed brachial plexus injury (n = 13). After flap transfer, 98% of patients were able to flex the elbow against gravity and 82.3% were able to flex against resistance. In the presented case, a 77-year-old man underwent resection of myxofibrosarcoma of the upper arm with elbow prosthesis placement and functional latissimus dorsi transfer. The patient was able to actively flex against gravity at 3-month follow-up. Conclusions: A review of the literature shows that nearly all patients undergoing functional latissimus dorsi transfer for upper-extremity reconstruction regain at least motion against gravity whereas a large proportion regain motion against resistance. Considerations when planning for functional latissimus dorsi transfer include patient positioning, appropriate tensioning of the muscle, safe inset, polarity, management of other affected upper-extremity joints, and educating patients on the expected outcomes. PMID:28293330
NASA Astrophysics Data System (ADS)
Bamsey, Matthew T.; Paul, Anna-Lisa; Graham, Thomas; Ferl, Robert J.
2014-10-01
Fluorescent imaging offers the ability to monitor biological functions, in this case biological responses to space-related environments. For plants, fluorescent imaging can include general health indicators such as chlorophyll fluorescence as well as specific metabolic indicators such as engineered fluorescent reporters. This paper describes the Flex Imager a fluorescent imaging payload designed for Middeck Locker deployment and now tested on multiple flight and flight-related platforms. The Flex Imager and associated payload elements have been developed with a focus on 'flexibility' allowing for multiple imaging modalities and change-out of individual imaging or control components in the field. The imaging platform is contained within the standard Middeck Locker spaceflight form factor, with components affixed to a baseplate that permits easy rearrangement and fine adjustment of components. The Flex Imager utilizes standard software packages to simplify operation, operator training, and evaluation by flight provider flight test engineers, or by researchers processing the raw data. Images are obtained using a commercial cooled CCD image sensor, with light-emitting diodes for excitation and a suite of filters that allow biological samples to be imaged over wavelength bands of interest. Although baselined for the monitoring of green fluorescent protein and chlorophyll fluorescence from Arabidopsis samples, the Flex Imager payload permits imaging of any biological sample contained within a standard 10 cm by 10 cm square Petri plate. A sample holder was developed to secure sample plates under different flight profiles while permitting sample change-out should crewed operations be possible. In addition to crew-directed imaging, autonomous or telemetric operation of the payload is also a viable operational mode. An infrared camera has also been integrated into the Flex Imager payload to allow concurrent fluorescent and thermal imaging of samples. The Flex Imager has been utilized to assess, in real-time, the response of plants to novel environments including various spaceflight analogs, including several parabolic flight environments as well as hypobaric plant growth chambers. Basic performance results obtained under these operational environments, as well as laboratory-based tests are described. The Flex Imager has also been designed to be compatible with emerging suborbital platforms.
Building flexible real-time systems using the Flex language
NASA Technical Reports Server (NTRS)
Kenny, Kevin B.; Lin, Kwei-Jay
1991-01-01
The design and implementation of a real-time programming language called Flex, which is a derivative of C++, are presented. It is shown how different types of timing requirements might be expressed and enforced in Flex, how they might be fulfilled in a flexible way using different program models, and how the programming environment can help in making binding and scheduling decisions. The timing constraint primitives in Flex are easy to use yet powerful enough to define both independent and relative timing constraints. Program models like imprecise computation and performance polymorphism can carry out flexible real-time programs. In addition, programmers can use a performance measurement tool that produces statistically correct timing models to predict the expected execution time of a program and to help make binding decisions. A real-time programming environment is also presented.
NASA Astrophysics Data System (ADS)
Xu, Zhida; Jiang, Jing; Wang, Xinhao; Han, Kevin; Ameen, Abid; Khan, Ibrahim; Chang, Te-Wei; Liu, Gang Logan
2016-03-01
We demonstrated a highly-sensitive, wafer-scale, highly-uniform plasmonic nano-mushroom substrate based on plastic for naked-eye plasmonic colorimetry and surface-enhanced Raman spectroscopy (SERS). We gave it the name FlexBrite. The dual-mode functionality of FlexBrite allows for label-free qualitative analysis by SERS with an enhancement factor (EF) of 108 and label-free quantitative analysis by naked-eye colorimetry with a sensitivity of 611 nm RIU-1. The SERS EF of FlexBrite in the wet state was found to be 4.81 × 108, 7 times stronger than in the dry state, making FlexBrite suitable for aqueous environments such as microfluid systems. The label-free detection of biotin-streptavidin interaction by both SERS and colorimetry was demonstrated with FlexBrite. The detection of trace amounts of the narcotic drug methamphetamine in drinking water by SERS was implemented with a handheld Raman spectrometer and FlexBrite. This plastic-based dual-mode nano-mushroom substrate has the potential to be used as a sensing platform for easy and fast analysis in chemical and biological assays.We demonstrated a highly-sensitive, wafer-scale, highly-uniform plasmonic nano-mushroom substrate based on plastic for naked-eye plasmonic colorimetry and surface-enhanced Raman spectroscopy (SERS). We gave it the name FlexBrite. The dual-mode functionality of FlexBrite allows for label-free qualitative analysis by SERS with an enhancement factor (EF) of 108 and label-free quantitative analysis by naked-eye colorimetry with a sensitivity of 611 nm RIU-1. The SERS EF of FlexBrite in the wet state was found to be 4.81 × 108, 7 times stronger than in the dry state, making FlexBrite suitable for aqueous environments such as microfluid systems. The label-free detection of biotin-streptavidin interaction by both SERS and colorimetry was demonstrated with FlexBrite. The detection of trace amounts of the narcotic drug methamphetamine in drinking water by SERS was implemented with a handheld Raman spectrometer and FlexBrite. This plastic-based dual-mode nano-mushroom substrate has the potential to be used as a sensing platform for easy and fast analysis in chemical and biological assays. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr08357e
NASA Technical Reports Server (NTRS)
Galofaro, Joel T.; Vayner, Boris V.; Hillard, Grover B.
2011-01-01
The present ground based investigations give the first definitive look describing the expected on-orbit charging behavior of Orion UltraFlex array coupons in the Low Earth Orbital and Geosynchronous Environments. Furthermore, it is important to note that the LEO charging environment also applies to the International Space Station as well as to the lunar mission charging environments. The GEO charging environment includes the bounding case for all lunar orbital and lunar surface mission environments. The UltraFlex thin film photovoltaic array technology has been targeted to become the sole power system for life support and on-orbit power for the manned Aires Crew Exploration Vehicle. It is therefore, crucial to gain an understanding of the complex charging behavior to answer some of the basic performance and survivability issues in an attempt to ascertain that a single UltraFlex array design will be able to cope with the projected worst case LEO and GEO charging environments. Testing was limited to four array coupons, two coupons each from two different array manufactures, Emcore and Spectrolab. The layout of each array design is identical and varies only in the actual cell technology used. The individual array cells from each manufacturer have an antireflection layered coating and come in two different varieties either uncoated (only AR coating) or coated with a thin conducting ITO layer. The LEO Plasma tests revealed that all four coupons passed the arc threshold -120 V bias tests. GEO electron gun charging tests revealed that only front side area of ITO coated coupons passed tests. Only the Emcore AR array passed backside Stage 2 GEO Tests.
Localized corrosion of high performance metal alloys in an acid/salt environment
NASA Technical Reports Server (NTRS)
Macdowell, L. G.; Ontiveros, C.
1991-01-01
Various vacuum jacketed cryogenic supply lines at the Space Shuttle launch site at Kennedy Space Center use convoluted flexible expansion joints. The atmosphere at the launch site has a very high salt content, and during a launch, fuel combustion products include hydrochloric acid. This extremely corrosive environment has caused pitting corrosion failure in the thin walled 304L stainless steel flex hoses. A search was done to find a more corrosion resistant replacement material. The study focussed on 19 metal alloys. Tests which were performed include electrochemical corrosion testing, accelerated corrosion testing in a salt fog chamber, and long term exposure at a beach corrosion testing site. Based on the results of these tests, several nickel based alloys were found to have very high resistance to this corrosive environment. Also, there was excellent agreement between the electrochemical tests and the actual beach exposure tests. This suggests that electrochemical testing may be useful for narrowing the field of potential candidate alloys before subjecting samples to long term beach exposure.
Xu, Zhida; Jiang, Jing; Wang, Xinhao; Han, Kevin; Ameen, Abid; Khan, Ibrahim; Chang, Te-Wei; Liu, Gang Logan
2016-03-21
We demonstrated a highly-sensitive, wafer-scale, highly-uniform plasmonic nano-mushroom substrate based on plastic for naked-eye plasmonic colorimetry and surface-enhanced Raman spectroscopy (SERS). We gave it the name FlexBrite. The dual-mode functionality of FlexBrite allows for label-free qualitative analysis by SERS with an enhancement factor (EF) of 10(8) and label-free quantitative analysis by naked-eye colorimetry with a sensitivity of 611 nm RIU(-1). The SERS EF of FlexBrite in the wet state was found to be 4.81 × 10(8), 7 times stronger than in the dry state, making FlexBrite suitable for aqueous environments such as microfluid systems. The label-free detection of biotin-streptavidin interaction by both SERS and colorimetry was demonstrated with FlexBrite. The detection of trace amounts of the narcotic drug methamphetamine in drinking water by SERS was implemented with a handheld Raman spectrometer and FlexBrite. This plastic-based dual-mode nano-mushroom substrate has the potential to be used as a sensing platform for easy and fast analysis in chemical and biological assays.
Ares I Flight Control System Design
NASA Technical Reports Server (NTRS)
Jang, Jiann-Woei; Alaniz, Abran; Hall, Robert; Bedrossian, Nazareth; Hall, Charles; Ryan, Stephen; Jackson, Mark
2010-01-01
The Ares I launch vehicle represents a challenging flex-body structural environment for flight control system design. This paper presents a design methodology for employing numerical optimization to develop the Ares I flight control system. The design objectives include attitude tracking accuracy and robust stability with respect to rigid body dynamics, propellant slosh, and flex. Under the assumption that the Ares I time-varying dynamics and control system can be frozen over a short period of time, the flight controllers are designed to stabilize all selected frozen-time launch control systems in the presence of parametric uncertainty. Flex filters in the flight control system are designed to minimize the flex components in the error signals before they are sent to the attitude controller. To ensure adequate response to guidance command, step response specifications are introduced as constraints in the optimization problem. Imposing these constraints minimizes performance degradation caused by the addition of the flex filters. The first stage bending filter design achieves stability by adding lag to the first structural frequency to phase stabilize the first flex mode while gain stabilizing the higher modes. The upper stage bending filter design gain stabilizes all the flex bending modes. The flight control system designs provided here have been demonstrated to provide stable first and second stage control systems in both Draper Ares Stability Analysis Tool (ASAT) and the MSFC 6DOF nonlinear time domain simulation.
Therapeutic hand-exercising device with cycling pressure value
NASA Technical Reports Server (NTRS)
Barthlome, D. E.
1974-01-01
Device exercises hands of persons whose fingers are generally straight and need to be flexed inward toward palms of hands. Device is extremely simple in design, which reduces costs, and fits all hand sizes. Patient can instantly free hand from device by pulling flap free from wrist of straps.
12 CFR 742.4 - RegFlex Relief.
Code of Federal Regulations, 2010 CFR
2010-01-01
... discretionary control can be delegated; (6) “Stress testing” of investments. Section 703.12(c) of this chapter concerning “stress testing” of securities holdings to assess the impact of an extreme interest rate shift; (7... nationally-recognized statistical rating organization; (ii) The security meets the definition of mortgage...
Benefits of a Single-Person Spacecraft for Weightless Operations
NASA Technical Reports Server (NTRS)
Griffin, Brand Norman
2012-01-01
Historically, less than 20 percent of crew time related to extravehicular activity (EVA) is spent on productive external work. For planetary operations space suits are still the logical choice; however for safe and rapid access to the weightless environment, spacecraft offer compelling advantages. FlexCraft, a concept for a single-person spacecraft, enables any-time access to space for short or long excursions by different astronauts. For the International Space Station (ISS), going outside is time-consuming, requiring pre-breathing, donning a fitted space suit, and pumping down an airlock. For each ISS EVA this is between 12.5 and 16 hours. FlexCraft provides immediate access to space because it operates with the same cabin atmosphere as its host. Furthermore, compared to the space suit pure oxygen environment, a mixed gas atmosphere lowers the fire risk and allows use of conventional materials and systems. For getting to the worksite, integral propulsion replaces hand-over-hand translation or having another crew member operate the robotic arm. This means less physical exertion and more time at the work site. Possibly more important, in case of an emergency, FlexCraft can return from the most distant point on ISS in less than a minute. The one-size-fits-all FlexCraft means no on-orbit inventory of parts or crew time required to fit all astronauts. With a shirtsleeve cockpit, conventional displays and controls are used, there is no suit trauma and because the work is not strenuous, no rest days are required. Furthermore, there is no need to collect hand tools because manipulators are equipped with force multiplying end-effectors that can deliver the precise torque for the job. FlexCraft is an efficient solution for asteroid exploration allowing all crew to use one vehicle with no risk of contamination. And, because FlexCraft is a vehicle, its design offers better radiation and micro-meteoroid protection than space suits.
FLEX: A Decisive Step Forward in NASA's Combustion Research Program
NASA Technical Reports Server (NTRS)
Hickman, John M.; Dietrich, Daniel L.; Hicks, Michael C.; Nayagam, Vedha; Stocker, Dennis
2012-01-01
Stemming from the need to prevent, detect and suppress on-board spacecraft fires, the NASA microgravity combustion research program has grown to include fundamental research. From early experiment, we have known that flames behave differently in microgravity, and this environment would provide an ideal laboratory for refining many of the long held principals of combustion science. A microgravity environment can provide direct observation of phenomena that cannot be observed on Earth. Through the years, from precursor work performed in drop towers leading to experiments on the International Space Station (ISS), discoveries have been made about the nature of combustion in low gravity environments. These discoveries have uncovered new phenomena and shed a light on many of the fundamental phenomena that drive combustion processes. This paper discusses the NASA microgravity combustion research program taking place in the ISS Combustion Integrated Rack, its various current and planned experiments, and the early results from the Flame Extinguishment (FLEX) Experiment.
Prader-Willi syndrome: is there a recognizable fetal phenotype?
Bigi, Nicole; Faure, Jean-Michel; Coubes, Christine; Puechberty, Jacques; Lefort, Geneviève; Sarda, Pierre; Blanchet, Patricia
2008-09-01
To determine fetal features, which could lead to the diagnosis of Prader-Willi syndrome (PWS) during pregnancy. We analyze the ultrasound features, genetic studies and pathologic findings in two cases of PWS diagnosed during pregnancy. In the first case, diminished fetal movement, polyhydramnios and oddly positioned hands and feet suggested PWS. Methylation studies confirmed diagnosis and a deletion was detected in the 15q11-q13 region. In the second case, similar ultrasound findings led to prenatal diagnosis of PWS with an abnormal methylation pattern compatible with uniparental disomy. Both fetuses had a characteristic appearance at 28 and 30 weeks' gestation, which included a peculiar position of hands with flexed wrists and dorsi-extended feet with flexed toes. The peculiar position of the extremities combined with diminished fetal movement and polyhydramnios seems to be characteristic and should suggest PWS. Copyright (c) 2008 John Wiley & Sons, Ltd.
Methods for design and evaluation of integrated hardware-software systems for concurrent computation
NASA Technical Reports Server (NTRS)
Pratt, T. W.
1985-01-01
Research activities and publications are briefly summarized. The major tasks reviewed are: (1) VAX implementation of the PISCES parallel programming environment; (2) Apollo workstation network implementation of the PISCES environment; (3) FLEX implementation of the PISCES environment; (4) sparse matrix iterative solver in PSICES Fortran; (5) image processing application of PISCES; and (6) a formal model of concurrent computation being developed.
Lau, Ernest W
2013-09-01
Conductor cable externalization with protrusion (CCE*) is highly prevalent among the Riata 8F and ST 7F defibrillation (DF) leads and infrequently present in the QuickSite and the QuickFlex coronary sinus (CS) leads (St. Jude Medical, Sylmar, CA, USA). A model for CCE* based on differential lead component pulling and conjugate extension with reciprocal compression-bending was developed. Extension of a proximal lead body segment by pectoral or cardiac movements causes reciprocal compression-bending of a distal lead body segment mediated by inextensible conductor cables running down a lead body fixed at various points by fibrous adhesions. The "sawing" action of these cables under tension causes inside-out abrasion of insulation leading to CCE*. DF leads from different manufacturers and the QuickFlex and QuickFlex μ CS leads were subjected to simulated differential pulling. Restitution from differential pulling followed three patterns: complete, partial without escalation, and incomplete with escalation. Only the last pattern (only shown by the Riata 8F and ST 7F leads) was associated with an increased risk to CCE*. For CS leads, deformation concentrated on the more flexible segment when the lead body did not have a uniform construction. The Durata, Riata ST Optim, QuickFlex μ, and Quartet leads should be relatively immune to CCE*. The Durata leads are extremely resistant to longitudinal deformation and probably cause mediastinal displacement rather than differential pulling in response to pectoral movements in vivo. Implantation techniques and lead designs can be used to minimize the risk of CCE*. A bench test for CCE* can be constructed. ©2013, The Author. Journal compilation ©2013 Wiley Periodicals, Inc.
Kinematics and aerodynamics of avian upstrokes during slow flight.
Crandell, Kristen E; Tobalske, Bret W
2015-08-01
Slow flight is extremely energetically costly per unit time, yet highly important for takeoff and survival. However, at slow speeds it is presently thought that most birds do not produce beneficial aerodynamic forces during the entire wingbeat: instead they fold or flex their wings during upstroke, prompting the long-standing prediction that the upstroke produces trivial forces. There is increasing evidence that the upstroke contributes to force production, but the aerodynamic and kinematic mechanisms remain unknown. Here, we examined the wingbeat cycle of two species: the diamond dove (Geopelia cuneata) and zebra finch (Taeniopygia guttata), which exhibit different upstroke styles - a wingtip-reversal and flexed-wing upstroke, respectively. We used a combination of particle image velocimetry and near-wake streamline measures alongside detailed 3D kinematics. We show that during the middle of the wingtip-reversal upstroke, the hand-wing has a high angular velocity (15.3±0.8 deg ms(-1)) and translational speed (8.4±0.6 m s(-1)). The flexed-wing upstroke, in contrast, has low wingtip speed during mid-upstroke. Instead, later in the stroke cycle, during the transition from upstroke to downstroke, it exhibits higher angular velocities (45.5±13.8 deg ms(-1)) and translational speeds (11.0±1.9 m s(-1)). Aerodynamically, the wingtip-reversal upstroke imparts momentum to the wake, with entrained air shed backward (visible as circulation of 14.4±0.09 m(2) s(-1)). In contrast, the flexed-wing upstroke imparts minimal momentum. Clap and peel in the dove enhances the time course for circulation production on the wings, and provides new evidence of convergent evolution on time-varying aerodynamic mechanisms during flapping in insects and birds. © 2015. Published by The Company of Biologists Ltd.
NASA Technical Reports Server (NTRS)
Rutledge, Sharon K.; Paulsen, Phillip E.; Brady, Joyce A.; Ciancone, Michael L.
1988-01-01
Fiberglass-epoxy composites are considered for use as structural members for the mast of the space station solar array panel. The low Earth orbital environment in which space station is to operate is composed mainly of atomic oxygen, which has been shown to cause erosion of many organic materials and some metals. Ground based testing in a plasma asher was performed to determine the extent of degradation of fiberglass-epoxy composites when exposed to a simulated atomic oxygen environment. During exposure, the epoxy at the surface of the composite was oxidized, exposing individual glass fibers which could easily be removed. Several methods of protecting the composite were evaluated in an atomic oxygen environment and with thermal cycling and flexing. The protection techniques evaluated to date include an aluminum braid covering, an indium-tin eutectic and a silicone based paint. The open aluminum braid offered little protection while the CV-1144 coating offered some initial protection against atomic oxygen, but appears to develop cracks which accelerate degradation when flexed. Coatings such as the In-Sn eutectic may provide adequate protection by containing the glass fibers even though mass loss still occurs.
Ares-I Bending Filter Design using a Constrained Optimization Approach
NASA Technical Reports Server (NTRS)
Hall, Charles; Jang, Jiann-Woei; Hall, Robert; Bedrossian, Nazareth
2008-01-01
The Ares-I launch vehicle represents a challenging flex-body structural environment for control system design. Software filtering of the inertial sensor output is required to ensure adequate stable response to guidance commands while minimizing trajectory deviations. This paper presents a design methodology employing numerical optimization to develop the Ares-I bending filters. The design objectives include attitude tracking accuracy and robust stability with respect to rigid body dynamics, propellant slosh, and flex. Under the assumption that the Ares-I time-varying dynamics and control system can be frozen over a short period of time, the bending filters are designed to stabilize all the selected frozen-time launch control systems in the presence of parameter uncertainty. To ensure adequate response to guidance command, step response specifications are introduced as constraints in the optimization problem. Imposing these constrains minimizes performance degradation caused by the addition of the bending filters. The first stage bending filter design achieves stability by adding lag to the first structural frequency to phase stabilize the first flex mode while gain stabilizing the higher modes. The upper stage bending filter design gain stabilizes all the flex bending modes. The bending filter designs provided here have been demonstrated to provide stable first and second stage control systems in both Draper Ares Stability Analysis Tool (ASAT) and the MSFC MAVERIC 6DOF nonlinear time domain simulation.
Majdani, Omid; Lenarz, Thomas
2017-01-01
Objectives This investigation evaluated the effect of cochlear implant (CI) electrode length on speech comprehension in quiet and noise and compare the results with those of EAS users. Methodes 91 adults with some degree of residual hearing were implanted with a FLEX20, FLEX24, or FLEX28 electrode. Some subjects were postoperative electric-acoustic-stimulation (EAS) users; the other subjects were in the groups of electric stimulation-only (ES-only). Speech perception was tested in quiet and noise at 3 and 6 months of ES or EAS use. Speech comprehension results were analyzed and correlated to electrode length. Results While the FLEX20 ES and FLEX24 ES groups were still in their learning phase between the 3 to 6 months interval, the FLEX28 ES group was already reaching a performance plateau at the three months appointment yielding remarkably high test scores. EAS subjects using FLEX20 or FLEX24 electrodes outscored ES-only subjects with the same short electrodes on all 3 tests at each interval, reaching significance with FLEX20 ES and FLEX24 ES subjects on all 3 tests at the 3-months interval and on 2 tests at the 6- months interval. Amongst ES-only subjects at the 3- months interval, FLEX28 ES subjects significantly outscored FLEX20 ES subjects on all 3 tests and the FLEX24 ES subjects on 2 tests. At the-6 months interval, FLEX28 ES subjects still exceeded the other ES-only subjects although the difference did not reach significance. Conclusions Among ES-only users, the FLEX28 ES users had the best speech comprehension scores, at the 3- months appointment and tendentially at the 6 months appointment. EAS users showed significantly better speech comprehension results compared to ES-only users with the same short electrodes. PMID:28505158
Büchner, Andreas; Illg, Angelika; Majdani, Omid; Lenarz, Thomas
2017-01-01
This investigation evaluated the effect of cochlear implant (CI) electrode length on speech comprehension in quiet and noise and compare the results with those of EAS users. 91 adults with some degree of residual hearing were implanted with a FLEX20, FLEX24, or FLEX28 electrode. Some subjects were postoperative electric-acoustic-stimulation (EAS) users; the other subjects were in the groups of electric stimulation-only (ES-only). Speech perception was tested in quiet and noise at 3 and 6 months of ES or EAS use. Speech comprehension results were analyzed and correlated to electrode length. While the FLEX20 ES and FLEX24 ES groups were still in their learning phase between the 3 to 6 months interval, the FLEX28 ES group was already reaching a performance plateau at the three months appointment yielding remarkably high test scores. EAS subjects using FLEX20 or FLEX24 electrodes outscored ES-only subjects with the same short electrodes on all 3 tests at each interval, reaching significance with FLEX20 ES and FLEX24 ES subjects on all 3 tests at the 3-months interval and on 2 tests at the 6- months interval. Amongst ES-only subjects at the 3- months interval, FLEX28 ES subjects significantly outscored FLEX20 ES subjects on all 3 tests and the FLEX24 ES subjects on 2 tests. At the-6 months interval, FLEX28 ES subjects still exceeded the other ES-only subjects although the difference did not reach significance. Among ES-only users, the FLEX28 ES users had the best speech comprehension scores, at the 3- months appointment and tendentially at the 6 months appointment. EAS users showed significantly better speech comprehension results compared to ES-only users with the same short electrodes.
The V-Flex, Triangle Orientation, and Catalan Numbers in Hexaflexagons
ERIC Educational Resources Information Center
Iacob, Ionut E.; McLean, T. Bruce; Wang, Hua
2012-01-01
Regular hexaflexagons mysteriously change faces as you pinch flex them. This paper describes a different flex, the V-flex, which allows the hexahexaflexagon (with only 9 faces under the pinch flex) to have 3420 faces. The article goes on to explain the classification of triangle orientations in a hexaflexagon and gives an example of the…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yoo, S.J.Ben; Lauer, Gregory S.
Extreme-science drives the need for distributed exascale processing and communications that are carefully, yet flexibly, managed. Exponential growth of data for scientific simulations, experimental data, collaborative data analyses, remote visualization and GRID computing requirements of scientists in fields as diverse as high energy physics, climate change, genomics, fusion, synchrotron radiation, material science, medicine, and other scientific disciplines cannot be accommodated by simply applying existing transport protocols to faster pipes. Further, scientific challenges today demand diverse research teams, heightening the need for and increasing the complexity of collaboration. To address these issues within the network layer and physical layer, we havemore » performed a number of research activities surrounding effective allocation and management of elastic optical network (EON) resources, particularly focusing on FlexGrid transponders. FlexGrid transponders support the opportunity to build Layer-1 connections at a wide range of bandwidths and to reconfigure them rapidly. The new flexibility supports complex new ways of using the physical layer that must be carefully managed and hidden from the scientist end-users. FlexGrid networks utilize flexible (or elastic) spectral bandwidths for each data link without using fixed wavelength grids. The flexibility in spectrum allocation brings many appealing features to network operations. Current networks are designed for the worst case impairments in transmission performance and the assigned spectrum is over-provisioned. In contrast, the FlexGrid networks can operate with the highest spectral efficiency and minimum bandwidth for the given traffic demand while meeting the minimum quality of transmission (QoT) requirement. Two primary focuses of our research are: (1) resource and spectrum allocation (RSA) for IP traffic over EONs, and (2) RSA for cross-domain optical networks. Previous work concentrates primarily on large file transfers within a single domain. Adding support for IP traffic changes the nature of the RSA problem: instead of choosing to accept or deny each request for network support, IP traffic is inherently elastic and thus lends itself to a bandwidth maximization formulation. We developed a number of algorithms that could be easily deployed within existing and new FlexGrid networks, leading to networks that better support scientific collaboration. Cross-domain RSA research is essential to support large-scale FlexGrid networks, since configuration information is generally not shared or coordinated across domains. The results presented here are in their early stages. They are technically feasible and practical, but still require coordination among organizations and equipment owners and a higher-layer framework for managing network requests.« less
ERIC Educational Resources Information Center
Christensen, Gayle S.; Feehan, Kathleen; Loss, Daniel
2007-01-01
Perhaps the most ambitious example of the way in which flexibility and accountability have been brought together can be found in the State Flex and Local Flex demonstration programs. Although no additional resources are provided to participating states and districts, the enhanced flexibility granted under State Flex and Local Flex allows…
United States Air Force Academy get-away-special flexible beam experiment
NASA Technical Reports Server (NTRS)
Bubb, Keith W.; Lamberson, Steven E.; Lash, Thomas A.
1989-01-01
The Department of Astronautics at the United States Air Force Academy is currently planning to fly an experiment in a NASA Get-Away-Special (GAS) canister. The experiment was named the flex beam experiment. The primary technical objective of the flex beam experiment is to measure the damping of a thin beam in the vacuum and zero G environment of space. By measuring the damping in space, it is hoped to determine the amount of damping the beam normally experiences due to the gravitational forces present on Earth. This will allow validation of models which predict the dynamics of thin beams in the space environment. The experiment will also allow the Academy to develop and improve its ability to perform experiments within the confines of a NASA GAS canister. Several experiments, of limited technical difficulty, were flown by the Academy. More complex experiments are currently planned and it is hoped to learn techniques with each space shuttle flight.
Strifling, Kelly M B; Lu, Na; Wang, Mei; Cao, Kevin; Ackman, Jeffrey D; Klein, John P; Schwab, Jeffrey P; Harris, Gerald F
2008-10-01
This prospective study analyzes the upper extremity kinematics of 10 children with spastic diplegic cerebral palsy using anterior and posterior walkers. Although both types of walkers are commonly prescribed by clinicians, no quantitative data comparing the two in regards to upper extremity motion has been published. The study methodology included testing of each subject with both types of walkers in a motion analysis laboratory after an acclimation period of at least 1 month. Overall results showed that statistically, both walkers are relatively similar. With both anterior and posterior walkers, the shoulders were extended, elbows flexed, and wrists extended. Energy expenditure, walking speed and stride length was also similar with both walker types. Several differences were also noted although not statistically significant. Anterior torso tilt was reduced with the posterior walker and shoulder extension and elbow flexion were increased. Outcomes analysis indicated that differences in upper extremity torso and joint motion were not dependent on spasticity or hand dominance. These findings may help to build an understanding of upper extremity motion in walker-assisted gait and potentially to improve walker prescription.
Qi, Peng; Gimode, Davis; Saha, Dipnarayan; Schröder, Stephan; Chakraborty, Debkanta; Wang, Xuewen; Dida, Mathews M; Malmberg, Russell L; Devos, Katrien M
2018-06-15
Research on orphan crops is often hindered by a lack of genomic resources. With the advent of affordable sequencing technologies, genotyping an entire genome or, for large-genome species, a representative fraction of the genome has become feasible for any crop. Nevertheless, most genotyping-by-sequencing (GBS) methods are geared towards obtaining large numbers of markers at low sequence depth, which excludes their application in heterozygous individuals. Furthermore, bioinformatics pipelines often lack the flexibility to deal with paired-end reads or to be applied in polyploid species. UGbS-Flex combines publicly available software with in-house python and perl scripts to efficiently call SNPs from genotyping-by-sequencing reads irrespective of the species' ploidy level, breeding system and availability of a reference genome. Noteworthy features of the UGbS-Flex pipeline are an ability to use paired-end reads as input, an effective approach to cluster reads across samples with enhanced outputs, and maximization of SNP calling. We demonstrate use of the pipeline for the identification of several thousand high-confidence SNPs with high representation across samples in an F 3 -derived F 2 population in the allotetraploid finger millet. Robust high-density genetic maps were constructed using the time-tested mapping program MAPMAKER which we upgraded to run efficiently and in a semi-automated manner in a Windows Command Prompt Environment. We exploited comparative GBS with one of the diploid ancestors of finger millet to assign linkage groups to subgenomes and demonstrate the presence of chromosomal rearrangements. The paper combines GBS protocol modifications, a novel flexible GBS analysis pipeline, UGbS-Flex, recommendations to maximize SNP identification, updated genetic mapping software, and the first high-density maps of finger millet. The modules used in the UGbS-Flex pipeline and for genetic mapping were applied to finger millet, an allotetraploid selfing species without a reference genome, as a case study. The UGbS-Flex modules, which can be run independently, are easily transferable to species with other breeding systems or ploidy levels.
Comprehensive profile of hip, knee and ankle ranges of motion in professional football players.
López-Valenciano, Alejandro; Ayala, Francisco; Vera-García, Francisco J; de Ste Croix, Mark; Hernández-Sánchez, Sergio; Ruiz-Pérez, Iñaki; Cejudo, Antonio; Santonja, Fernando
2017-10-31
Limited ranges of motion (ROM) have been considered as a primary risk factor for some football injuries, but only a few studies have analysed differences in lower extremity joints. The main purposes were (a) to describe the lower extremity ROM profile in professional football players; and (b) to examine differences between goalkeepers and outfield players. 82 professional male football players from 4 teams were measured in the 2013 pre-season. Measures of passive hip (flexion with knee flexed [PHFKF] and extended [PHFKE], extension [PHE], abduction [PHA], external [PHER] and internal [PHIR] rotation), knee (flexion [PKF]) and ankle (dorsiflexion with knee flexed [ADFKF] and extended [ADFKE]) ROMs were taken. Magnitude-based inferences exploring differences between player position and limb were made. 46% of all participants showed restricted PHFKE and/or around 30% showed restricted ADFKF ROM values. Contrarily, most players reported normal PHFKF, PHE, PHIR and PHER as well as PKF ROM scores with percentage values close to 100%. Bilateral meaningful differences for PHA, PHIR and PHER were found in approximately 30% of outfield players and goalkeepers. Statistical analysis found trivial differences between players for PHFKE, PHE, PHIR, PHER, ADFKE and ADFKF. However, moderate differences between players were found for PHFKF, PHA and PKF, with goalkeepers demonstrating higher values than outfield players. The findings of this study reinforce the necessity of prescribing exercises aimed at improving PHFKE and ADFKF ROM within everyday football training routines. In addition, as some bilateral deficits were observed, unilateral training should be considered where appropriate.
A Revised STONEMAN for Distributed Ada (Trademark) Support Environments.
1984-01-01
MA 02154 San Diego, CA 92152 Chuck Waltrip Philip Myers Johns Hopkins University Dave Pasterchik Applied Physics Lab NRVELEX Johns Hopkins Road FLEX...Georgia Tech Atlanta, GA 30332 Reed Kotler Lockheed Missiles & Space Dick Drake 1111 Lockheed Way IBM Sunnyvale, CA 94086 Federal Systems Division 102/075
Qi, Yi; Kim, Jihoon; Nguyen, Thanh D; Lisko, Bozhena; Purohit, Prashant K; McAlpine, Michael C
2011-03-09
The development of a method for integrating highly efficient energy conversion materials onto soft, biocompatible substrates could yield breakthroughs in implantable or wearable energy harvesting systems. Of particular interest are devices which can conform to irregular, curved surfaces, and operate in vital environments that may involve both flexing and stretching modes. Previous studies have shown significant advances in the integration of highly efficient piezoelectric nanocrystals on flexible and bendable substrates. Yet, such inorganic nanomaterials are mechanically incompatible with the extreme elasticity of elastomeric substrates. Here, we present a novel strategy for overcoming these limitations, by generating wavy piezoelectric ribbons on silicone rubber. Our results show that the amplitudes in the waves accommodate order-of-magnitude increases in maximum tensile strain without fracture. Further, local probing of the buckled ribbons reveals an enhancement in the piezoelectric effect of up to 70%, thus representing the highest reported piezoelectric response on a stretchable medium. These results allow for the integration of energy conversion devices which operate in stretching mode via reversible deformations in the wavy/buckled ribbons.
Kappelgaard, Anne-Marie; Mikkelsen, Søren; Bagger, Claus; Fuchs, Gitte Schøning
2012-01-01
Growth hormone (GH) is used to treat growth failure in children and metabolic impairments in adults with GH deficiency (GHD). Treatment requires daily subcutaneous injections that may affect treatment outcomes, and subsequently efficacy outcomes. To enhance potential adherence, improved GH delivery device systems are being developed. To compare patient acceptability and usability of Norditropin FlexPro/FlexPro PenMate with Norditropin NordiFlex/NordiFlex PenMate for GH administration in children/adolescents with GHD. A multinational, open-label, uncontrolled study. Patients (n = 50; 4-18 years) currently on GH therapy injected test medium into a foam pad. Ease-of-use and patient device preference were recorded by questionnaire. The majority (80%) of patients preferred FlexPro PenMate over NordiFlex PenMate with 96% and 84%, respectively, reporting that they found the FlexPro PenMate system user-friendly and that they were highly confident using it. The FlexPro system was well accepted by patients. This may facilitate greater adherence to treatment and improve patient outcomes.
Yılmaz, K; Uslu, G; Özyürek, T
2018-02-13
To compare the effect of autoclave cycles on the surface topography and roughness of HyFlex CM and HyFlex EDM instruments using atomic force microscopy (AFM) analysis. Eight new files of each brand were subdivided into four subgroups (n = 2/each subgroup). One group was allocated as the control group and not subjected to autoclave sterilization. The other three groups were subjected to different numbers (1, 5, and 10) of autoclave sterilization cycles. After the cycle instruments were subjected to AFM analysis. Roughness average (Ra) and the root mean square (RMS) values were chosen to investigate the surface features of endodontic files. The data was analyzed using one-way ANOVA and post hoc Tamhane tests at 5% significant level. The lowest Ra and RMS values were observed in the HyFlex EDM files that served as the control and in those subjected to a single cycle of autoclave sterilization (P < 0.05). The highest Ra and RMS values were observed in the HyFlex CM and HyFlex EDM files that were subjected to 10 cycles of autoclave sterilization (P < 0.05). The surface roughness values of the HyFlex CM group showed a significant increase after ten autoclave cycles, whereas those of the HyFlex EDM group exhibited a significant change after five autoclave cycles (P < 0.05). Although the initial surface roughness values of the HyFlex EDM files were lower than those of the HyFlex CM files, the surface roughness values of the EDM files showed a statistically significant increase after 5 cycles of autoclave sterilization. In contrast, the surface roughness values of the HyFlex CM files did not increase until 10 cycles of autoclave sterilization. Present study indicated that autoclave sterilization negatively affected the surface roughness of the tested NiTi files.
An isolated dorso-medial dislocation of navicular bone: A case report.
Singh, Varun Kumar; Kashyap, Abhishek; Vargaonkar, Gauresh; Kumar, Ramesh
2015-03-01
An isolated dislocation of tarsal navicular is extremely rare injury. Usually it is associated with fracture of navicular itself or other tarsal bones of foot along with disruption of medial or lateral column of foot. Mechanism of injury is complex but usually a severe abduction force is required to produce such injury in a planter flexed foot. A 30 year old male presented with isolated navicular dislocation. Management required open reduction and fixation with k-wires. These injuries have specific complications including avascular necrosis of navicular and post-traumatic arthritis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cygan, David
The Gas Technology Institute (GTI), along with its partner Integrated CHP Systems Corporation, has developed and demonstrated an Ultra-Low-Nitrogen Oxide (ULN) Flexible Combined Heat and Power (FlexCHP) system that packages a state-of-the-art Capstone C65 gas microturbine and Johnston PFXX100 boiler with an innovative natural gas-fired supplemental burner. Supplemental burners add heat as needed in response to facility demand, which increases energy efficiency, but typically raises exhaust NOx levels, degrading local air quality unless a costly and complicated catalytic treatment system is added. The FlexCHP system increases energy efficiency and achieves the 2007 California Air Resource Board (CARB) distributed generation emissionsmore » standards for Nitrogen oxides (NOx), Carbon Monoxide (CO), and Total Hydrocarbons (THC) without catalytic exhaust gas treatment. The key to this breakthrough performance is a simple and reliable burner design which utilizes staged combustion with engineered internal recirculation. This ULN burner system successfully uses turbine exhaust as an oxidizer, while achieving high efficiencies and low emissions. In tests at its laboratory facilities in Des Plaines, Illinois, GTI validated the ability of the system to achieve emissions of NOx, CO, and THC below the CARB criteria of 0.07, 0.10, and 0.02 lb/MW-h respectively. The FlexCHP system was installed at the field demonstration site, Inland Empire Foods, in Riverside, California to verify performance of the technology in an applied environment. The resulting Combined Heat and Power (CHP) package promises to make CHP implementation more attractive, mitigate greenhouse gas emissions, and improve the reliability of electricity supply.« less
NASA Astrophysics Data System (ADS)
Horswell, I.; Gimenez, E. N.; Marchal, J.; Tartoni, N.
2011-01-01
Hybrid silicon photon-counting detectors are becoming standard equipment for many synchrotron applications. The latest in the Medipix family of read-out chips designed as part of the Medipix Collaboration at CERN is the Medipix3, which while maintaining the same pixel size as its predecessor, offers increased functionality and operating modes. The active area of the Medipix3 chip is approx 14mm × 14mm (containing 256 × 256 pixels) which is not large enough for many detector applications, this results in the need to tile many sensors and chips. As a first step on the road to develop such a detector, it was decided to build a prototype single chip readout system to gain the necessary experience in operating a Medipix3 chip. To provide a flexible learning and development tool it was decided to build an interface based on the recently released FlexRIOTM system from National Instruments and to use the LabVIEWTM graphical programming environment. This system and the achieved performance are described in this paper.
High volume nanoscale roll-based imprinting using jet and flash imprint lithography
NASA Astrophysics Data System (ADS)
Ahn, Se Hyun; Miller, Michael; Yang, Shuqiang; Ganapathisubramanian, Maha; Menezes, Marlon; Singh, Vik; Wan, Fen; Choi, Jin; Xu, Frank; LaBrake, Dwayne; Resnick, Douglas J.; Hofemann, Paul; Sreenivasan, S. V.
2014-03-01
Extremely large-area roll-to-roll manufacturing on flexible substrates is ubiquitous for applications such as paper and plastic processing. The challenge is to extend this approach to the realm of nanopatterning and realize similar benefits. Display applications, including liquid crystal (LCD), organic light emitting diode (OLED) and flexible displays are particularly interesting because of the ability to impact multiple levels in the basic display. Of particular interest are the polarizer, DBEF, thin film transistor and color filter; roll-based imprinting has the opportunity to create high performance components within the display while improving the cost of ownership of the panel. Realization of these devices requires both a scalable imprinting technology and tool. In this paper, we introduce a high volume roll-based nanopatterning system, the LithoFlex 350TM. The LithoFlex 350 uses an inkjet based imprinting process similar to the technology demonstrator tool, the LithoFlex 100, introduced in 2012. The width of the web is 350mm and patterning width is 300mm. The system can be configured either for Plate-to-Roll (P2R) imprinting (in which a rigid template is used to pattern the flexible web material) or for Roll-to-Plate imprinting (R2P) (in which a web based template is used to pattern either wafers or panels). Also described in this paper are improvements to wire grid polarizer devices. By optimizing the deposition, patterning and etch processes, we have been able to create working WGPs with transmittance and extinction ratios as high as 44% and 50,000, respectively.
NASA Astrophysics Data System (ADS)
Merchel, Renée. A.; Barnes, Kelli S.; Taylor, Kenneth D.
2015-03-01
INTRODUCTION: The ABC® D-Flex Probe utilizes argon beam coagulation (ABC) technology to achieve hemostasis during minimally invasive surgery. A handle on the probe allows for integration with robotic surgical systems and introduces ABC to the robotic toolbox. To better understand the utility of D-Flex, this study compares the performance of the D-Flex probe to an existing ABC laparoscopic probe through ex vivo tissue analysis. METHODS: Comparisons were performed to determine the effect of four parameters: ABC device, tissue type, activation duration, and distance from tissue. Ten ABC D-Flex probes were used to create 30 burn samples for each comparison. Ex vivo bovine liver and porcine muscle were used as tissue models. The area and depth of each burn was measured using a light microscope. The resulting dimensional data was used to correlate tissue effect with each variable. RESULTS: D-Flex created burns which were smaller in surface area than the laparoscopic probe at all power levels. Additionally, D-Flex achieved thermal penetration levels equivalent to the laparoscopic probe. CONCLUSION: D-Flex implements a small 7F geometry which creates a more focused beam. When used with robotic precision, quick localized superficial hemostasis can be achieved with minimal collateral damage. Additionally, D-Flex achieved equivalent thermal penetration levels at lower power and argon flow-rate settings than the laparoscopic probe.
DOT National Transportation Integrated Search
2009-09-01
The University of Idaho's entry into the 2009 SAE Clean Snowmobile Challenge (CSC) was a semi-direct-injection (SDI) two-stroke powered REV-XP snowmobile modified to use flex fuel. The flex fuel engine produces stock engine power on any blend of etha...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-19
..., as Modified by Amendment No. 1, To Adopt Rules Extending the Maximum Term of FLEX Index and FLEX...-2010-40 in order to revise the Statutory Basis section and to adopt rules extending the maximum term of... maximum term of FLEX Index and FLEX Equity options to the same term permissible on NYSE Arca Inc. (``Arca...
Integration of Flex Nozzle System and Electro Hydraulic Actuators to Solid Rocket Motors
NASA Astrophysics Data System (ADS)
Nayani, Kishore Nath; Bajaj, Dinesh Kumar
2017-10-01
A rocket motor assembly comprised of solid rocket motor and flex nozzle system. Integration of flex nozzle system and hydraulic actuators to the solid rocket motors are done after transportation to the required place where integration occurred. The flex nozzle system is integrated to the rocket motor in horizontal condition and the electro hydraulic actuators are assembled to the flex nozzle systems. The electro hydraulic actuators are connected to the hydraulic power pack to operate the actuators. The nozzle-motor critical interface are insulation diametrical compression, inhibition resin-28, insulation facial compression, shaft seal `O' ring compression and face seal `O' ring compression.
CABS-flex predictions of protein flexibility compared with NMR ensembles
Jamroz, Michal; Kolinski, Andrzej; Kmiecik, Sebastian
2014-01-01
Motivation: Identification of flexible regions of protein structures is important for understanding of their biological functions. Recently, we have developed a fast approach for predicting protein structure fluctuations from a single protein model: the CABS-flex. CABS-flex was shown to be an efficient alternative to conventional all-atom molecular dynamics (MD). In this work, we evaluate CABS-flex and MD predictions by comparison with protein structural variations within NMR ensembles. Results: Based on a benchmark set of 140 proteins, we show that the relative fluctuations of protein residues obtained from CABS-flex are well correlated to those of NMR ensembles. On average, this correlation is stronger than that between MD and NMR ensembles. In conclusion, CABS-flex is useful and complementary to MD in predicting protein regions that undergo conformational changes as well as the extent of such changes. Availability and implementation: The CABS-flex is freely available to all users at http://biocomp.chem.uw.edu.pl/CABSflex. Contact: sekmi@chem.uw.edu.pl Supplementary information: Supplementary data are available at Bioinformatics online. PMID:24735558
CABS-flex predictions of protein flexibility compared with NMR ensembles.
Jamroz, Michal; Kolinski, Andrzej; Kmiecik, Sebastian
2014-08-01
Identification of flexible regions of protein structures is important for understanding of their biological functions. Recently, we have developed a fast approach for predicting protein structure fluctuations from a single protein model: the CABS-flex. CABS-flex was shown to be an efficient alternative to conventional all-atom molecular dynamics (MD). In this work, we evaluate CABS-flex and MD predictions by comparison with protein structural variations within NMR ensembles. Based on a benchmark set of 140 proteins, we show that the relative fluctuations of protein residues obtained from CABS-flex are well correlated to those of NMR ensembles. On average, this correlation is stronger than that between MD and NMR ensembles. In conclusion, CABS-flex is useful and complementary to MD in predicting protein regions that undergo conformational changes as well as the extent of such changes. The CABS-flex is freely available to all users at http://biocomp.chem.uw.edu.pl/CABSflex. sekmi@chem.uw.edu.pl Supplementary data are available at Bioinformatics online. © The Author 2014. Published by Oxford University Press.
Office design's impact on sick leave rates.
Bodin Danielsson, Christina; Chungkham, Holendro Singh; Wulff, Cornelia; Westerlund, Hugo
2014-01-01
The effect of office type on sickness absence among office employees was studied prospectively in 1852 employees working in (1) cell-offices; (2) shared-room offices; (3) small, (4) medium-sized and (5) large open-plan offices; (6) flex-offices and (7) combi-offices. Sick leaves were self-reported two years later as number of (a) short and (b) long (medically certified) sick leave spells as well as (c) total number of sick leave days. Multivariate logistic regression analysis was used, with adjustment for background factors. A significant excess risk for sickness absence was found only in terms of short sick leave spells in the three open-plan offices. In the gender separate analysis, this remained for women, whereas men had a significantly increased risk in flex-offices. For long sick leave spells, a significantly higher risk was found among women in large open-plan offices and for total number of sick days among men in flex-offices. A prospective study of the office environment's effect on employees is motivated by the high rates of sick leaves in the workforce. The results indicate differences between office types, depending on the number of people sharing workspace and the opportunity to exert personal control as influenced by the features that define the office types.
2002-11-14
KENNEDY SPACE CENTER, FLA. -- Workers on Launch Pad 39A inspect an oxygen flex hose fitting. Through manual inspection and using helium detectors, the flex hose was identified as the source of an oxygen leak in Endeavour's mid-body. Visual inspection found a deformity in the flex line braid where it connects to rigid tubing. The entire flex hose assembly and bulkhead fitting were removed early today, and work is under way to complete the installation of a replacement.
2002-11-14
KENNEDY SPACE CENTER, FLA. -- Workers on Launch Pad 39A inspect an oxygen flex hose fitting. Through manual inspection and using helium detectors, the flex hose was identified as the source of an oxygen leak in Endeavour's mid-body. Visual inspection found a deformity in the flex line braid where it connects to rigid tubing. The entire flex hose assembly and bulkhead fitting were removed early today, and work is under way to complete the installation of a replacement.
Modeling a solar-heated anaerobic digester for the developing world using system dynamics
NASA Astrophysics Data System (ADS)
Bentley, Johanna Lynn
Much of the developing world lacks access to a dependable source of energy. Agricultural societies such as Mozambique and Papua New Guinea could sustain a reliable energy source through the microbacterial decomposition of animal and crop waste. Anaerobic digestion produces methane, which can be used directly for heating, cooking, and lighting. Adding a solar component to the digester provides a catalyst for bacteria activity, accelerating digestion and increasing biogas production. Using methane decreases the amount of energy expended by collecting and preparing firewood, eliminates hazardous health effects linked to inhalation of particles, and provides energy close to where it is needed. The purpose of this work is two fold: initial efforts focus on the development and validation of a computer-based system dynamics model that combines elements of the anaerobic digestion process in order to predict methane output; second, the model is flexed to explore how the addition of a solar component increases robustness of the design, examines predicted biogas generation as a function of varying input conditions, and determines how best to configure such systems for use in varying developing world environments. Therefore, the central components of the system: solar insolation, waste feedstock, bacteria population and consumption rates, and biogas production are related both conceptually and mathematically through a serious of equations, conversions, and a causal loop and feedback diagram. Given contextual constraints and initial assumptions for both locations, it was determined that solar insolation and subsequent digester temperature control, amount of waste, and extreme weather patterns had the most significant impact on the system as a whole. Model behavior was both reproducible and comparable to that demonstrated in existing experimental systems. This tool can thus be flexed to fit specific contexts within the developing world to improve the standard of living of many people, without significantly altering everyday activities.
Low Cost Space Demonstration for a Single-Person Spacecraft
NASA Technical Reports Server (NTRS)
Griffin, Brand N.; Dischinger, Charles
2011-01-01
This paper introduces a concept for a single-person spacecraft and presents plans for flying a low-cost, robotic demonstration mission. Called FlexCraft, the vehicle integrates propulsion and robotics into a small spacecraft that enables rapid, shirt-sleeve access to space. It can be flown by astronauts or tele-operated and is equipped with interchangeable manipulators used for maintaining the International Space Station (ISS), exploring asteroids, and servicing telescopes or satellites. Most FlexCraft systems are verified using ground facilities; however, a test in the weightless environment is needed to assess propulsion and manipulator performance. For this, a simplified, unmanned, version of FlexCraft is flown on a low-cost launch vehicle to a 350 km circular orbit. After separation from the upper stage, the vehicle returns to a target box mounted on the stage testing the propulsion and control capability. The box is equipped with manipulator test items that are representative of tasks performed on ISS, asteroid missions, or for satellites servicing. Nominal and off-nominal operations are conducted over 3 days then the vehicle re-enters the atmosphere without becoming a debris hazard. From concept to management to operations, the FlexCraft demonstration is designed to be low cost project that is launched within three years. This is possible using a simplified test configuration that eliminates nine systems unique to the operational version and by designing-to-availability. For example, the propulsion system is the same as the Manned Maneuvering Unit because it capable, simple, human-rated and all components or equivalent parts are available. A description of the launch vehicle options, mission operations, configuration, and demonstrator subsystems is presented.
Structural analysis of HyFlex EDM instruments.
Iacono, F; Pirani, C; Generali, L; Bolelli, G; Sassatelli, P; Lusvarghi, L; Gandolfi, M G; Giorgini, L; Prati, C
2017-03-01
To compare the phase transformation behaviour, the microstructure, the nano-hardness and the surface chemistry of electro-discharge machined HyFlex EDM instruments with conventionally manufactured HyFlex CM. New and laboratory used HyFlex EDM were examined by X-ray diffraction (XRD) and differential scanning calorimetry (DSC). Nano-hardness and modulus of elasticity were also investigated using a maximum load of 20 mN with a minimum of 40 significant indentations for each sample. Raman spectroscopy and field emission-scanning electron microscope (FE-SEM) were used to assess the surface chemistry of HyFlex EDM. HyFlex CM were subjected to the same investigations and used as a comparison. Nano-indentation data were statistically analysed using the Student's t-test. XRD analysis on HyFlex EDM revealed the presence of martensite and rhombohedral R-phase, while a mixture of martensite and austenite structure was identified in HyFlex CM. DSC analysis also disclosed higher austenite finish (Af) temperatures for electro-discharge machining (EDM) instruments. Significant differences in nano-hardness and modulus of elasticity were found between EDM and CM files (P < 0.05). FE-SEM and EDS analyses confirmed that both new EDM and CM files were covered by an oxide layer. Micro-Raman spectroscopy assessed the presence of rutile-TiO 2 . HyFlex EDM revealed peculiar structural properties, such as increased phase transformation temperatures and hardness. Present results corroborated previous findings and shed light on the enhanced mechanical behaviour of these instruments. © 2016 International Endodontic Journal. Published by John Wiley & Sons Ltd.
Longitudinal comparison study of pressure relief (C-Flex) vs. CPAP in OSA patients.
Dolan, Diana C; Okonkwo, Renata; Gfullner, Florian; Hansbrough, J Randall; Strobel, Richard J; Rosenthal, Leon
2009-03-01
Continuous positive airway pressure (CPAP) devices with the option of flexible pressure delivery (e.g., C-Flex) are thought to provide an improved degree of comfort and result in better therapeutic adherence while maintaining standard CPAP efficacy. The purpose of this study was to compare adherence and subjective measures of comfort between C-Flex and CPAP treatment. The study was an international, multisite, single-blinded study with participants randomized to either C-Flex or CPAP. Participants completed subjective measures of sleepiness and comfort at baseline, and at 30-, 90-, and 180-day follow-ups. Additionally, compliance data were downloaded from the device at each follow-up. Repeated measures analysis of variance was used to assess the effects of treatment. There were 138 men and 46 women (average age of 48 +/- 9.2, average Epworth Sleepiness Scale score of 14.9 +/- 3.6, and average diagnostic apnea/hypopnea index (AHI) of 51.9 +/- 27.7). C-Flex and CPAP groups were comparable on baseline measures, achieved comparable AHI on titration, and had comparable PAP pressure requirements. C-Flex users had comparable average hours of use per night and total nights of use across the study, but had a trend (p < .07) toward achieving greater total hours of utilization. While both groups had comparable decreases in sleepiness, C-Flex users reported on visual analog scales greater comfort (64.3 vs. 57.4; p = .01). The results of this study demonstrated that C-Flex has comparable resolution of respiratory indices and adherence. Furthermore, C-Flex users reported greater mask comfort.
Kernel and System Procedures in Flex.
1983-08-01
System procedures on which the operating system for the Flex computer is based. These are the low level rOCedures Whbich are used to implement the compilers, file-store* coummand interpreters etc on Flex. 168 ... System procedures on which the operating system for the Flex computer is based. These are the low level procedures which are used to implement the...privileged mode. They form the interface between the user and a particular operating system written on top of the Kernel.
Flexible radioluminescence imaging for FDG-guided surgery
DOE Office of Scientific and Technical Information (OSTI.GOV)
King, Martin T., E-mail: mking@lroc.harvard.edu; J
Purpose: Flexible radioluminescence imaging (Flex-RLI) is an optical method for imaging {sup 18}F-fluorodeoxyglucose (FDG)-avid tumors. The authors hypothesize that a gadolinium oxysulfide: terbium (GOS:Tb) flexible scintillator, which loosely conforms to the body contour, can enhance tumor signal-to-background ratio (SBR) compared with RLI, which utilizes a flat scintillator. The purpose of this paper is to characterize flex-RLI with respect to alternative modalities including RLI, beta-RLI (RLI with gamma rejection), and Cerenkov luminescence imaging (CLI). Methods: The photon sensitivity, spatial resolution, and signal linearity of flex-RLI were characterized with in vitro phantoms. In vivo experiments utilizing 13 nude mice inoculated with themore » head and neck (UMSCC1-Luc) cell line were then conducted in accordance with the institutional Administrative Panel on Laboratory Animal Care. After intravenous injection of {sup 18}F-FDG, the tumor SBR values for flex-RLI were compared to those for RLI, beta-RLI, and CLI using the Wilcoxon signed rank test. Results: With respect to photon sensitivity, RLI, beta-RLI, and flex-RLI produced 1216.2, 407.0, and 98.6 times more radiance per second than CLI. Respective full-width half maximum values across a 0.5 mm capillary tube were 6.9, 6.4, 2.2, and 1.5 mm, respectively. Flex-RLI demonstrated a near perfect correlation with {sup 18}F activity (r = 0.99). Signal uniformity for flex-RLI improved after more aggressive homogenization of the GOS powder with the silicone elastomer during formulation. In vivo, the SBR value for flex-RLI (median 1.29; interquartile range 1.18–1.36) was statistically greater than that for RLI (1.08; 1.02–1.14; p < 0.01) by 26%. However, there was no statistically significant difference in SBR values between flex-RLI and beta-RLI (p = 0.92). Furthermore, there was no statistically significant difference in SBR values between flex-RLI and CLI (p = 0.11) in a more limited dataset. Conclusions: Flex-RLI provides high quality images with SBRs comparable to those from CLI and beta-RLI in a single 10 s acquisition.« less
FlexAID: Revisiting Docking on Non-Native-Complex Structures.
Gaudreault, Francis; Najmanovich, Rafael J
2015-07-27
Small-molecule protein docking is an essential tool in drug design and to understand molecular recognition. In the present work we introduce FlexAID, a small-molecule docking algorithm that accounts for target side-chain flexibility and utilizes a soft scoring function, i.e. one that is not highly dependent on specific geometric criteria, based on surface complementarity. The pairwise energy parameters were derived from a large dataset of true positive poses and negative decoys from the PDBbind database through an iterative process using Monte Carlo simulations. The prediction of binding poses is tested using the widely used Astex dataset as well as the HAP2 dataset, while performance in virtual screening is evaluated using a subset of the DUD dataset. We compare FlexAID to AutoDock Vina, FlexX, and rDock in an extensive number of scenarios to understand the strengths and limitations of the different programs as well as to reported results for Glide, GOLD, and DOCK6 where applicable. The most relevant among these scenarios is that of docking on flexible non-native-complex structures where as is the case in reality, the target conformation in the bound form is not known a priori. We demonstrate that FlexAID, unlike other programs, is robust against increasing structural variability. FlexAID obtains equivalent sampling success as GOLD and performs better than AutoDock Vina or FlexX in all scenarios against non-native-complex structures. FlexAID is better than rDock when there is at least one critical side-chain movement required upon ligand binding. In virtual screening, FlexAID results are lower on average than those of AutoDock Vina and rDock. The higher accuracy in flexible targets where critical movements are required, intuitive PyMOL-integrated graphical user interface and free source code as well as precompiled executables for Windows, Linux, and Mac OS make FlexAID a welcome addition to the arsenal of existing small-molecule protein docking methods.
Rehabilitation Exercises to Induce Balanced Scapular Muscle Activity in an Anti-gravity Posture
Ishigaki, Tomonobu; Yamanaka, Masanori; Hirokawa, Motoki; Tai, Keita; Ezawa, Yuya; Samukawa, Mina; Tohyama, Harukazu; Sugawara, Makoto
2014-01-01
[Purpose] The purpose of this study was to compare the intramuscular balance ratios of the upper trapezius muscle (UT) and the lower trapezius muscle (LT), and the intermuscular balance ratios of the UT and the serratus anterior muscle (SA) among prone extension (ProExt), prone horizontal abduction with external rotation (ProHAbd), forward flexion in the side-lying position (SideFlex), side-lying external rotation (SideEr), shoulder flexion with glenohumeral horizontal abduction load (FlexBand), and shoulder flexion with glenohumeral horizontal adduction load (FlexBall) in the standing posture. [Methods] The electromyographic (EMG) activities of the UT, LT and SA were measured during the tasks. The percentage of maximum voluntary isometric contraction (%MVIC) was calculated for each muscle, and the UT/LT ratios and the UT/SA ratios were compared among the tasks. [Results] The UT/LT ratio with the FlexBand was not significantly different from those of the four exercises in the side-lying and prone postures. The UT/SA ratio with the FlexBall demonstrated appropriate balanced activity. [Conclusion] In an anti-gravity posture, we recommend the FlexBand and the FlexBall for inducing balanced UT/LT and UT/SA ratios, respectively. PMID:25540485
Rehabilitation Exercises to Induce Balanced Scapular Muscle Activity in an Anti-gravity Posture.
Ishigaki, Tomonobu; Yamanaka, Masanori; Hirokawa, Motoki; Tai, Keita; Ezawa, Yuya; Samukawa, Mina; Tohyama, Harukazu; Sugawara, Makoto
2014-12-01
[Purpose] The purpose of this study was to compare the intramuscular balance ratios of the upper trapezius muscle (UT) and the lower trapezius muscle (LT), and the intermuscular balance ratios of the UT and the serratus anterior muscle (SA) among prone extension (ProExt), prone horizontal abduction with external rotation (ProHAbd), forward flexion in the side-lying position (SideFlex), side-lying external rotation (SideEr), shoulder flexion with glenohumeral horizontal abduction load (FlexBand), and shoulder flexion with glenohumeral horizontal adduction load (FlexBall) in the standing posture. [Methods] The electromyographic (EMG) activities of the UT, LT and SA were measured during the tasks. The percentage of maximum voluntary isometric contraction (%MVIC) was calculated for each muscle, and the UT/LT ratios and the UT/SA ratios were compared among the tasks. [Results] The UT/LT ratio with the FlexBand was not significantly different from those of the four exercises in the side-lying and prone postures. The UT/SA ratio with the FlexBall demonstrated appropriate balanced activity. [Conclusion] In an anti-gravity posture, we recommend the FlexBand and the FlexBall for inducing balanced UT/LT and UT/SA ratios, respectively.
User’s Guide for Naval Material Command’s Life Cycle Cost (FLEX) Model.
1982-04-01
MATERIAL COMMANDl’S 3 LIFE CYCLE COST (FLEX) MODEL Icc FoIuhrInomto -- -- P ea eCo tc Pleale Cona, ______ _____-Thims document rc~ ofl 5C72 -lot REPORT...Material Command’s Life Cycle Cost (FLEX) Prep. 4/82 ___ Model ______________ ______________ 7. Author(s) S. Performing Organization Rapt. No. R. Dress (ESA...WANG 1I. Abstract (Limit: 200 words) The FLEX-9E life cycle cost comp~uter model is a user-oriented methodology accommodating most cost structures and
STS-113 workers work on oxygen leak in Endeavor's mid-body
NASA Technical Reports Server (NTRS)
2002-01-01
KENNEDY SPACE CENTER, FLA. -- Workers on Launch Pad 39A inspect an oxygen flex hose fitting. Through manual inspection and using helium detectors, the flex hose was identified as the source of an oxygen leak in Endeavour's mid-body. Visual inspection found a deformity in the flex line braid where it connects to rigid tubing. The entire flex hose assembly and bulkhead fitting were removed early today, and work is under way to complete the installation of a replacement.
Initial Ares I Bending Filter Design
NASA Technical Reports Server (NTRS)
Jang, Jiann-Woei; Bedrossian, Nazareth; Hall, Robert; Norris, H. Lee; Hall, Charles; Jackson, Mark
2007-01-01
The Ares-I launch vehicle represents a challenging flex-body structural environment for control system design. Software filtering of the inertial sensor output will be required to ensure control system stability and adequate performance. This paper presents a design methodology employing numerical optimization to develop the Ares-I bending filters. The filter design methodology was based on a numerical constrained optimization approach to maximize stability margins while meeting performance requirements. The resulting bending filter designs achieved stability by adding lag to the first structural frequency and hence phase stabilizing the first Ares-I flex mode. To minimize rigid body performance impacts, a priority was placed via constraints in the optimization algorithm to minimize bandwidth decrease with the addition of the bending filters. The bending filters provided here have been demonstrated to provide a stable first stage control system in both the frequency domain and the MSFC MAVERIC time domain simulation.
Tracking C. elegans and its neuromuscular activity using NemaFlex II
NASA Astrophysics Data System (ADS)
van Bussel, Frank; Rahman, Mizanur; Blawzdziewicz, Jerzy; Vanapalli, Siva
NemaFlex is a recently developed experimental platform designed to analyze the movement and muscular strength of crawling C. elegans. Physically it is a microfluidic device consisting of an array of deformable PDMS pillars, with which the C. elegans interacts in the course of moving through the system; image data is then acquired through a transparent top plate. The software component uses this image data to track the worm's movements and measure pillar deflections and thereby the forces exerted by the worm, in a fully automated, high-throughput manner. In order to correlate the force results with muscle activations the pillar deflections need to be precisely associated with mechanical contact on the worm's body, which requires accurate determination and representation of the body's position within the complex background. Here we discuss issues encountered in extracting this position data from the surrounding environment.
Saito, Shigeyoshi; Tanaka, Keiko; Hashido, Takashi
2016-07-01
This study aimed to compare the uniformity of fat suppression and image quality between liver acquisition with volume acceleration flex (LAVA-Flex) and LAVA on 60-cm conventional-bore and 70-cm wide-bore 3.0-T magnetic resonance imaging (MRI). The uniformity of fat suppression by LAVA-Flex and LAVA was assessed as the efficiency of suppression of superficial fat at the levels of the liver dome, porta, and renal hilum. Percentage standard deviation (%SD) was calculated using the following equation: %SD (%) = 100 × SD of the regions of interest (ROIs)/mean value of the signal intensity (SI) in the ROIs. Signal-to-noise ratio (SNR) and contrast ratio (CR) were calculated. In the LAVA sequence, the %SD in all slices on wide-bore 3.0-T MRI was significantly higher than that on conventional-bore 3.0-T MRI (P < 0.01). However, there was no significant difference in fat signal uniformity between the conventional and wide-bore scanners when LAVA-Flex was used. In the liver, there were no significant differences in SNR between the two sequences. However, the SNR in the pancreas was lower for the wide-bore scanner than for the conventional-bore scanner for both sequences (P < 0.05). There were no significant differences in CR for the liver and fat between LAVA-Flex and LAVA in both scanners. The CR in the LAVA-Flex images obtained by wide-bore MRI was significantly higher than that in the LAVA-Flex images recorded by conventional-bore MRI (P < 0.001). LAVA-Flex offers more homogenous fat suppression in the upper abdomen than LAVA for both conventional and wide-bore 3.0-T MRI.
The Best Workout on Earth, and in Space
NASA Technical Reports Server (NTRS)
2001-01-01
SpiraFlex(R) is a revolutionary new patented technology for storing and delivering mechanical power in industrial, consumer, and fitness equipment. NASA research facilities and funding helped to develop the "Resistance Exercise Device" (RED), powered by SpiraFlex. SpiraFlex duplicates the benefits of free-weights in a lightweight, portable, and safe system. The RED system is presently aboard the International Space Station (ISS) and is used by the crewmembers as a primary countermeasure against musculoskeletal degradation caused by microgravity. Using SpiraFlex technology, Schwinn Cycling & Fitness, Inc., of Boulder, Colorado, launched an international fitness program for health clubs and select retail distributors, called RiPP(TM) (Resistance Performance Program). RiPP is an exercise program that uses RiPP Pro machines, powered by SpiraFlex technology.
Spyridaki, M; Höh, H
2010-03-01
The aim of this study was to evaluate the incidence of posterior capsule opacification up to 50 months following 1.7-mm bimanual MICS-cataract surgery. Bimanual MICS cataract surgery was performed in 197 eyes (135 patients) via two 1.7-mm corneal incisions. Four MICS acrylic foldable IOLs were implanted: AcriSmart 48S-5, n = 54 (Acritec GmbH, Hennigsdorf, now AT.Smart 48S Carl-Zeiss-Meditec, AG, Jena, Germany), ThinLens UltraChoice 1.0, n = 53 (Technomed GmbH, Baesweiler, Germany), AcriFlex 46, n = 41 und AcriFlex 48 CSE, n = 7 (Acrimed GmbH, Berlin, now: Lentis L-303, Oculentis GmbH, Berlin, Germany) and CareFlex, n = 43 (w2o Medizintechnik AG, Bruchsal, Germany). Statistical analysis was performed using the Kaplan-Meier technique. High levels of completeness of follow-up rates were: ThinLens 96%, CareFlex 100%, AcriSmart 93%, AcriFlex 92%. The capsulotomy rate was 43.13% for ThinLens within a mean/max. follow-up period of 801/1131 days, 34.88% for CareFlex (565/872 days), 40% for AcriSmart (988/1506 days) and 15.91% for AcriFlex (728/975 days). By limiting the follow-up period to a comparable maximum of 850 days for all four IOLs, our capsulotomy rates were as follows: ThinLens 33.33%, CareFlex 32.56 %, AcriSmart 20.0% and AcriFlex 11.36%. MICS IOLs have higher capsulotomy rates than hydrophobic acrylic lenses and sharp-edged silicone lenses. In literature comparisons MICS-IOLs do not exceed the variance levels of capsulotomy rates of PMMA, hydrophilic acrylic and silicone lenses without sharp edges. Cases of decentration or luxation of MICS-IOLs following Neodym:YAG laser capsulotomy were not detected. Capsulotomy frequency with the CareFlex was statistically significantly higher in comparison to the AcriSmart (Log Rank Mantel Cox Test, p = 0.007) and AcriFlex (log rank Mantel Cox test, p = 0.002). Capsulotomy rates observed varied for the four MICS-IOL-types tested. The posterior capsule opacification frequency of the two best MICS-IOLs (AcriFlex, AcriSmart) did not exceed the higher variance levels of posterior capsule opacification rates of the round-edged "conventional" non-MICS IOLs of PMMA, silicone or hydrophilic acryl material. Sharp-edged silicone or hydrophobic acrylic "conventional" lenses have shown lower posterior capsule opacification rates. Georg Thieme Verlag KG Stuttgart, New York.
40 CFR 63.5460 - What definitions apply to this subpart?
Code of Federal Regulations, 2012 CFR
2012-07-01
... combination of smaller leather pieces and leather fibers, which when joined together, form an integral..., thus, cannot withstand 5,000 Maeser Flexes with a Maeser Flex Testing Machine or a method approved by... Maeser Flex Testing Machine or a method approved by the Administrator prior to initial water penetration...
40 CFR 63.5460 - What definitions apply to this subpart?
Code of Federal Regulations, 2014 CFR
2014-07-01
... combination of smaller leather pieces and leather fibers, which when joined together, form an integral..., thus, cannot withstand 5,000 Maeser Flexes with a Maeser Flex Testing Machine or a method approved by... Maeser Flex Testing Machine or a method approved by the Administrator prior to initial water penetration...
40 CFR 63.5460 - What definitions apply to this subpart?
Code of Federal Regulations, 2013 CFR
2013-07-01
... combination of smaller leather pieces and leather fibers, which when joined together, form an integral..., thus, cannot withstand 5,000 Maeser Flexes with a Maeser Flex Testing Machine or a method approved by... Maeser Flex Testing Machine or a method approved by the Administrator prior to initial water penetration...
Boakye, Cedar H A; Patel, Ketan; Doddapaneni, Ravi; Bagde, Arvind; Behl, Gautam; Chowdhury, Nusrat; Safe, Stephen; Singh, Mandip
2016-07-01
In this study, we developed cationic ultra-flexible nanocarriers (UltraFLEX-Nano) to surmount the skin barrier structure and to potentiate the topical delivery of a highly lipophilic antioxidative diindolylmethane derivative (DIM-D) for the inhibition of UV-induced DNA damage and skin carcinogenesis. UltraFLEX-Nano was prepared with 1,2-dipalmitoyl-sn-glycero-3-phosphocholine, 1,2-dioleoyl-3-trimethylammonium-propane, cholesterol and tween-80 by ethanolic injection method; was characterized by Differential Scanning Calorimetric (DSC), Fourier Transform Infrared (FT-IR) and Atomic Force Microscopic (phase-imaging) analyses and permeation studies were performed in dermatomed human skin. The efficacy of DIM-D-UltraFLEX-Nano for skin cancer chemoprevention was evaluated in UVB-induced skin cancer model in vivo. DIM-D-UltraFLEX-Nano formed a stable mono-dispersion (110.50±0.71nm) with >90% encapsulation of DIM-D that was supported by HPLC, DSC, FT-IR and AFM phase imaging. The blank formulation was non-toxic to human embryonic kidney cells. UltraFLEX-Nano was vastly deformable and highly permeable across the stratum corneum; there was significant (p<0.01) skin deposition of DIM-D for UltraFLEX-Nano that was superior to PEG solution (13.83-fold). DIM-D-UltraFLEX-Nano pretreatment delayed the onset of UVB-induced tumorigenesis (2 weeks) and reduced (p<0.05) the number of tumors observed in SKH-1 mice (3.33-fold), which was comparable to pretreatment with sunscreen (SPF30). Also, DIM-D-UltraFLEX-Nano caused decrease (p<0.05) in UV-induced DNA damage (8-hydroxydeoxyguanosine), skin inflammation (PCNA), epidermal hyperplasia (c-myc, CyclinD1), immunosuppression (IL10), cell survival (AKT), metastasis (Vimentin, MMP-9, TIMP1) but increase in apoptosis (p53 and p21). UltraFLEX-Nano was efficient in enhancing the topical delivery of DIM-D. DIM-D-UltraFLEX-Nano was efficacious in delaying skin tumor incidence and multiplicity in SKH mice comparable to sunscreen (SPF30). Copyright © 2016 Elsevier B.V. All rights reserved.
Junior, Roberto Moriggi; Berton, Ricardo; de Souza, Thiago Mattos Frota; Chacon-Mikahil, Mara Patrícia Traina; Cavaglieri, Cláudia Regina
2017-04-01
It has been suggested that flexibility training may reduce the total volume of training during resistance trainings. The purpose of this study was to compare the effect of flexibility training immediately before resistance training (FLEX-RT) versus resistance training without flexibility training (RT) on maximum strength and the vastus lateralis muscle cross-sectional area (CSA). Participants had each leg assigned to RT or FLEX-RT. Both groups performed four sets of leg extensions to voluntary failure of 80% of one repetition maximum (1RM); however, FLEX-RT performed two sets of 25 s of static stretching before resistance training. Number of repetitions and total volume were calculated during weeks 1-5 and 6-10. Vastus lateralis muscle CSA, 1RM, and flexibility were assessed at baseline and after 10 weeks. The number of repetitions and total training volume were greater for RT than FLEX-RT for weeks 1-5 and 6-10. Regarding the vastus lateralis muscle CSA, a main time effect was observed, however, greater change was observed for RT than FLEX-RT (12.7 and 7.4%, respectively). A main time effect for 1RM was also observed with similar changes for RT and FLEX-RT (12.7 and 12.9%, respectively). Flexibility was increased pre- to post-training for FLEX-RT with greater change for FLEX-RT (10.1%) than RT (2.1%). These results show that performing flexibility training immediately before resistance training can contribute to a lower number of repetitions, total volume, and muscle hypertrophy.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-20
... Options Transaction Charge (including the Cabinet Options Transaction Charge) as well as the Broker-Dealer FLEX transaction fee, for members executing facilitation orders pursuant to Exchange Rule 1064 when... average daily volume (including both FLEX and non-FLEX transactions) exceeds 10,000 contracts per day in a...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-08
... amend Phlx Rule 1079 (FLEX Index, Equity and Currency Options) to extend a pilot program that eliminates...\\ \\3\\ In addition to FLEX Options, FLEX currency options are also traded on the Exchange. These flexible index, equity, and currency options provide investors the ability to customize basic option...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-17
.... \\3\\ In addition to FLEX Options, FLEX currency options are also traded on the Exchange. These flexible index, equity, and currency options provide investors the ability to customize basic option... expiration dates within five years. See Rule 1079. FLEX currency options traded on the Exchange are also...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-04
... series.\\8\\ The annual report will also contain information and analysis of FLEX Options trading patterns... will also contain information and analysis of FLEX Options trading patterns, and index price volatility... To Establish a Pilot Program To Modify FLEX Option Exercise Settlement Values and Minimum Value Sizes...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-05
... information and analysis of FLEX Options trading patterns. The Exchange also provided the Commission, on a... Effectiveness of Proposed Rule Change To Extend Pilot Programs Relating to FLEX Exercise Settlement Values and... exercise settlement values and the elimination of minimum value sizes for Flexible Exchange Options (``FLEX...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-30
... Effectiveness of Proposed Rule Change Related to Extending the FLEX Exercise Settlement Values Pilot October 24... regarding permissible exercise settlement values for FLEX Index Options.\\5\\ The text of the proposed rule... things, established a pilot program regarding permissible exercise settlement values for FLEX Index...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-08
... report also contained information and analysis of FLEX Index Options trading patterns. The Exchange also... Effectiveness of Proposed Rule Change Related to Extending the FLEX Exercise Settlement Values Pilot November 2... regarding permissible exercise settlement values for FLEX Index Options, which pilot program is currently...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-28
... will have no negative impact on these FCUs. The proposed rule also removes the automatic exemption from... proposed change. RegFlex FCUs currently operating under the automatic exemption criteria for a RegFlex... not meet the standards for automatic qualification will now, like current non-RegFlex FCUs, have...
Resistive flex sensors: a survey
NASA Astrophysics Data System (ADS)
Saggio, Giovanni; Riillo, Francesco; Sbernini, Laura; Quitadamo, Lucia Rita
2016-01-01
Resistive flex sensors can be used to measure bending or flexing with relatively little effort and a relatively low budget. Their lightness, compactness, robustness, measurement effectiveness and low power consumption make these sensors useful for manifold applications in diverse fields. Here, we provide a comprehensive survey of resistive flex sensors, taking into account their working principles, manufacturing aspects, electrical characteristics and equivalent models, useful front-end conditioning circuitry, and physic-bio-chemical aspects. Particular effort is devoted to reporting on and analyzing several applications of resistive flex sensors, related to the measurement of body position and motion, and to the implementation of artificial devices. In relation to the human body, we consider the utilization of resistive flex sensors for the measurement of physical activity and for the development of interaction/interface devices driven by human gestures. Concerning artificial devices, we deal with applications related to the automotive field, robots, orthosis and prosthesis, musical instruments and measuring tools. The presented literature is collected from different sources, including bibliographic databases, company press releases, patents, master’s theses and PhD theses.
Hussein, A I; Stranart, J C; Meguid, S A; Bogoch, E R
2011-02-01
Silicone implants are used for prosthetic arthroplasty of metacarpophalangeal (MCP) joints severely damaged by rheumatoid arthritis. Different silicone elastomer MCP implant designs have been developed, including the Swanson and the NeuFlex implants. The goal of this study was to compare the in vitro mechanical behavior of Swanson and NeuFlex MCP joint implants. Three-dimensional (3D) finite element (FE) models of the silicone implants were modeled using the commercial software ANSYS and subjected to angular displacement from 0 deg to 90 deg. FE models were validated using mechanical tests of implants incrementally bent from 0 deg to 90 deg in a joint simulator. Swanson size 2 and 4 implants were compared with NeuFlex size 10 and 30 implants, respectively. Good agreement was observed throughout the range of motion for the flexion bending moment derived from 3D FE models and mechanical tests. From 30 deg to 90 deg, the Swanson 2 demonstrated a greater resistance to deformation than the NeuFlex 10 and required a greater bending moment for joint flexion. For larger implant sizes, the NeuFlex 30 had a steeper moment-displacement curve, but required a lower moment than the Swanson 4, due to implant preflexion. On average, the stress generated at the implant hinge from 30 deg to 90 deg was lower in the NeuFlex than in the Swanson. On average, starting from the neutral position of 30 deg for the preflexed NeuFlex implant, higher moments were required to extend the NeuFlex implants to 0 deg compared with the Swanson implants, which returned spontaneously to resting position. Implant toggling within the medullary canals was less in the NeuFlex than in the Swanson. The differential performance of these implants may be useful in implant selection based on the preoperative condition(s) of the joint and specific patient functional needs.
Effects of flexible ureteroscopy on renal blood flow: a prospective evaluation.
Sener, Tarik Emre; Tanidir, Yiloren; Bin Hamri, Saeed; Sever, Ibrahim Halil; Ozdemir, Burcu; Al-Humam, Abdulla; Traxer, Olivier
2018-02-20
This study aimed to investigate the effects of flexible ureteroscopy (F-URS) on renal blood flow using renal Doppler ultrasound (US). Patients undergoing F-URS were scheduled for Doppler US preoperatively and postoperatively. Peak systolic velocity (PSV), end-diastolic velocity (EDV), resistive index (RI) and pulsatility index (PI) were reported. Technical details, operation time, stone characteristics and complications were recorded. Patients were grouped as 9.5/11.5-Flex-X2, 10/12-Flex-X2, 10/12-Flex-XC, 12/14-Flex-X2 and 12/14-Flex-XC, with 28, six, three, seven and two patients in each group, respectively. Forty-six patients with a mean age of 41.24 years and stone volume of 1685 mm³ were enrolled. The PSV, EDV, PI and RI of renal arteries in all groups in preoperative and postoperative periods were similar. Arcuate artery measurements in all groups were also similar in preoperative and postoperative periods, without any significant difference except in two parameters: RI in the 9.5/11.5-Flex-X2 group and PSV in the 12/14-Flex-X2 group. The resistive index in the arcuate artery of the 9.5/11.5-Flex-X2 group was increased from 0.59 to 0.62 cm/sec postoperatively. The PSV in the arcuate artery of the 12/14-Flex-X2 group was decreased from 30.9 to 27.2 cm/sec. Three patients had urinary tract infections postoperatively and two had sepsis. This study suggests that compatible ureteroscope-ureteral access sheath combinations with a lumen difference of more than 1.5 Fr can provide safe outcomes in terms of renal blood flow. F-URS can safely be performed in terms of renal perfusion and complication rates with appropriate equipment and instruments.
Technical evaluation and assessment of CNG/LPG bi-fuel and flex-fuel vehicle viability
NASA Astrophysics Data System (ADS)
Sinor, J. E.
1994-05-01
This report compares vehicles using compressed natural gas (CNG), liquefied petroleum gas (LPG), and combinations of the two in bi-fuel or flex-fuel configurations. Evidence shows that environmental and energy advantages can be gained by replacing two-fuel CNG/gasoline vehicles with two-fuel or flex-fuel systems to be economically competitive, it is necessary to develop a universal CNG/LPG pressure-regulator-injector and engine control module to switch from one tank to the other. For flex-fuel CNG/LPG designs, appropriate composition sensors, refueling pumps, fuel tanks, and vaporizers are necessary.
Nocera, Alberto; Wang, Yan; Patel, Niravkumar D.; ...
2018-05-31
Here, we study the magnetic and charge dynamical response of a Hubbard model in a two-leg ladder geometry using the density matrix renormalization group (DMRG) method and the random phase approximation within the fluctuation-exchange approximation (FLEX). Our calculations reveal that FLEX can capture the main features of the magnetic response from weak up to intermediate Hubbard repulsion for doped ladders, when compared with the numerically exact DMRG results. However, while at weak Hubbard repulsion both the spin and charge spectra can be understood in terms of weakly interacting electron-hole excitations across the Fermi surface, at intermediate coupling DMRG shows gappedmore » spin excitations at large momentum transfer that remain gapless within the FLEX approximation. For the charge response, FLEX can only reproduce the main features of the DMRG spectra at weak coupling and high doping levels, while it shows an incoherent character away from this limit. Overall, our analysis shows that FLEX works surprisingly well for spin excitations at weak and intermediate Hubbard U values even in the difficult low-dimensional geometry such as a two-leg ladder. Finally, we discuss the implications of our results for neutron scattering and resonant inelastic x-ray scattering experiments on two-leg ladder cuprate compounds.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nocera, Alberto; Wang, Yan; Patel, Niravkumar D.
Here, we study the magnetic and charge dynamical response of a Hubbard model in a two-leg ladder geometry using the density matrix renormalization group (DMRG) method and the random phase approximation within the fluctuation-exchange approximation (FLEX). Our calculations reveal that FLEX can capture the main features of the magnetic response from weak up to intermediate Hubbard repulsion for doped ladders, when compared with the numerically exact DMRG results. However, while at weak Hubbard repulsion both the spin and charge spectra can be understood in terms of weakly interacting electron-hole excitations across the Fermi surface, at intermediate coupling DMRG shows gappedmore » spin excitations at large momentum transfer that remain gapless within the FLEX approximation. For the charge response, FLEX can only reproduce the main features of the DMRG spectra at weak coupling and high doping levels, while it shows an incoherent character away from this limit. Overall, our analysis shows that FLEX works surprisingly well for spin excitations at weak and intermediate Hubbard U values even in the difficult low-dimensional geometry such as a two-leg ladder. Finally, we discuss the implications of our results for neutron scattering and resonant inelastic x-ray scattering experiments on two-leg ladder cuprate compounds.« less
Alternative Fuels Data Center: City of Hoover Fleet Boasts 200-Plus Flex
Quality (CMAQ) Improvement Program. In response, the City of Hoover submitted a proposal to install a flex-fuel vehicles (FFVs) in hopes of reducing emissions and improving the region's air quality. At the : Municipal Fuel: E85 Flex Fuel Vehicles: 212 Infrastructure: Municipal E85 station Motivations: Air quality
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-26
... the Commission a proposal to amend Phlx Rule 1079 (FLEX Index, Equity and Currency Options) to permit... Options may have expiration dates within five years. See Phlx Rule 1079. FLEX currency option contracts... Exchange proposes to amend Phlx Rule 1079 to allow certain FLEX Options, which are identical in all terms...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-28
... have expiration dates within five years. See Rule 1079. FLEX currency options traded on the Exchange... purpose of this proposed rule change is to amend Phlx Rule 1079 (FLEX Index, Equity and Currency Options...'' or ``Pilot''). Rule 1079 deals with the process of listing and trading FLEX equity, index, and...
Flex-Time. A Catalyst Occasional Paper.
ERIC Educational Resources Information Center
Catalyst, New York, NY.
Contains history, case studies, and discussion of the use and benefits of flex-time employment, a pattern of working hours in which individual employees begin and end their work day at times of their choice, within certain limits, as long as they work a prescribed number of hours. The paper addresses the following topics: (1) What is flex-time,…
Schlepers, M; Gelauf, J; Wertenbroek, N; Nielen, M
2013-07-01
Porcine Circovirus type 2 (PCV2) is a ubiquitous infection and major cause of production loss for the pig industry. The aim of this study was to evaluate the effect of vaccination against PCV2 on technical results of pigs on an organic breeding and fattening farm, focussing on growth and mortality of weaned piglets and fattening pigs. The study was based on retrospective data between January 2009 and May 2011. During the study period, three subsequent vaccination strategies were used: 1. Stellamune One, 2. Stellamune One+CircoFLEX, 3. MycoFLEX+CircoFLEX. From these three periods, the corresponding management- and slaughterhouse data were analysed by an ANOVA-test. Due to few data in period 2 and an outbreak of Actinobacillus pleuropneumoniae during periods 2 and 3, these two periods were combined in one period and analysed by a two-sample t-test. Mortality of weaned piglets decreased with 3.6% (0.6 - 6.6%) (P0.023) in comparison to period 1 and average daily weight gain improved by 21 gram (7 - 34 gram) (P0.004) in periods 2 and 3. Mortality of fattening pigs was 2.3% (1.2 - 3.5%) (P0.001) less than in period 1 and corrected energy conversion rate improved 0.27 (0.05 - 0.49) (P0.017). There was no significant effect on slaughterhouse parameters. In conclusion, vaccination against PCV2 improved technical results of weaned and fattening pigs on this farm. The advantage of vaccination with MycoFLEX+CircoFLEX instead of Stellamune One+CircoFLEX is that the two FLEX-vaccines can be mixed and administered as a one shot vaccine, reducing work load and animal stressors.
Papp, Gergely; Felisaz, Franck; Sorez, Clement; Lopez-Marrero, Marcos; Janocha, Robert; Manjasetty, Babu; Gobbo, Alexandre; Belrhali, Hassan; Bowler, Matthew W; Cipriani, Florent
2017-10-01
Automated sample changers are now standard equipment for modern macromolecular crystallography synchrotron beamlines. Nevertheless, most are only compatible with a single type of sample holder and puck. Recent work aimed at reducing sample-handling efforts and crystal-alignment times at beamlines has resulted in a new generation of compact and precise sample holders for cryocrystallography: miniSPINE and NewPin [see the companion paper by Papp et al. (2017, Acta Cryst., D73, 829-840)]. With full data collection now possible within seconds at most advanced beamlines, and future fourth-generation synchrotron sources promising to extract data in a few tens of milliseconds, the time taken to mount and centre a sample is rate-limiting. In this context, a versatile and fast sample changer, FlexED8, has been developed that is compatible with the highly successful SPINE sample holder and with the miniSPINE and NewPin sample holders. Based on a six-axis industrial robot, FlexED8 is equipped with a tool changer and includes a novel open sample-storage dewar with a built-in ice-filtering system. With seven versatile puck slots, it can hold up to 112 SPINE sample holders in uni-pucks, or 252 miniSPINE or NewPin sample holders, with 36 samples per puck. Additionally, a double gripper, compatible with the SPINE sample holders and uni-pucks, allows a reduction in the sample-exchange time from 40 s, the typical time with a standard single gripper, to less than 5 s. Computer vision-based sample-transfer monitoring, sophisticated error handling and automatic error-recovery procedures ensure high reliability. The FlexED8 sample changer has been successfully tested under real conditions on a beamline.
Next-Generation Single-Use Ureteroscopes: An In Vitro Comparison.
Tom, Westin R; Wollin, Daniel A; Jiang, Ruiyang; Radvak, Daniela; Simmons, Walter Neal; Preminger, Glenn M; Lipkin, Michael E
2017-12-01
Single-use ureteroscopes have been gaining popularity in recent years. We compare the optics, deflection, and irrigation flow of two novel single-use flexible ureteroscopes-the YC-FR-A and the NeoFlex-with contemporary reusable and single-use flexible ureteroscopes. Five flexible ureteroscopes, YC-FR-A (YouCare Tech, China), NeoFlex (Neoscope, Inc., USA), LithoVue (Boston Scientific, USA), Flex-Xc (Karl Storz, Germany), and Cobra (Richard Wolf, Germany), were assessed in vitro for image resolution, distortion, field of view, depth of field, color representation, and grayscale imaging. Ureteroscope deflection and irrigation were also compared. The YC-FR-A showed a resolution of 5.04 lines/mm and 4.3% image distortion. NeoFlex showed a resolution of 17.9 lines/mm and 14.0% image distortion. No substantial difference was demonstrated regarding the other optic characteristics between the two. Across all tested ureteroscopes, single-use or reusable, the digital scopes performed best with regard to optics. The YC-FR-A had the greatest deflection at baseline, but lacks two-way deflection. The NeoFlex had comparable deflection at baseline to reusable devices. Both ureteroscopes had substantial loss of deflection with instruments in the working channel. The YC-FR-A had the greatest irrigation rate. The NeoFlex has comparable irrigation to contemporary ureteroscopes. The YouCare single-use fiberoptic flexible ureteroscope and NeoFlex single-use digital flexible ureteroscope perform comparably to current reusable ureteroscopes, possibly making each a viable alternative in the future. Newer YouCare single-use flexible ureteroscopes with a digital platform and two-way deflection may be more competitive, while the NeoFlex devices are undergoing rapid improvement as well. Further testing is necessary to validate the clinical performance and utility of these ureteroscopes, given the wide variety of single-use devices under development.
Promising Results from Three NASA SBIR Solar Array Technology Development Programs
NASA Technical Reports Server (NTRS)
Eskenazi, Mike; White, Steve; Spence, Brian; Douglas, Mark; Glick, Mike; Pavlick, Ariel; Murphy, David; O'Neill, Mark; McDanal, A. J.; Piszczor, Michael
2005-01-01
Results from three NASA SBIR solar array technology programs are presented. The programs discussed are: 1) Thin Film Photovoltaic UltraFlex Solar Array; 2) Low Cost/Mass Electrostatically Clean Solar Array (ESCA); and 3) Stretched Lens Array SquareRigger (SLASR). The purpose of the Thin Film UltraFlex (TFUF) Program is to mature and validate the use of advanced flexible thin film photovoltaics blankets as the electrical subsystem element within an UltraFlex solar array structural system. In this program operational prototype flexible array segments, using United Solar amorphous silicon cells, are being manufactured and tested for the flight qualified UltraFlex structure. In addition, large size (e.g. 10 kW GEO) TFUF wing systems are being designed and analyzed. Thermal cycle and electrical test and analysis results from the TFUF program are presented. The purpose of the second program entitled, Low Cost/Mass Electrostatically Clean Solar Array (ESCA) System, is to develop an Electrostatically Clean Solar Array meeting NASA s design requirements and ready this technology for commercialization and use on the NASA MMS and GED missions. The ESCA designs developed use flight proven materials and processes to create a ESCA system that yields low cost, low mass, high reliability, high power density, and is adaptable to any cell type and coverglass thickness. All program objectives, which included developing specifications, creating ESCA concepts, concept analysis and trade studies, producing detailed designs of the most promising ESCA treatments, manufacturing ESCA demonstration panels, and LEO (2,000 cycles) and GEO (1,350 cycles) thermal cycling testing of the down-selected designs were successfully achieved. The purpose of the third program entitled, "High Power Platform for the Stretched Lens Array," is to develop an extremely lightweight, high efficiency, high power, high voltage, and low stowed volume solar array suitable for very high power (multi-kW to MW) applications. These objectives are achieved by combining two cutting edge technologies, the SquareRigger solar array structure and the Stretched Lens Array (SLA). The SLA SquareRigger solar array is termed SLASR. All program objectives, which included developing specifications, creating preliminary designs for a near-term SLASR, detailed structural, mass, power, and sizing analyses, fabrication and power testing of a functional flight-like SLASR solar blanket, were successfully achieved.
NASA Technical Reports Server (NTRS)
Latimer, J. G.; Pappas, T.; Mitchell, C. A.
1986-01-01
Eggplant (Solanum melongena L. var. esculentum 'Burpee's Black Beauty') and soybean [Glycine max (L.) Merr. 'Wells II'] seedlings were assigned to a greenhouse or a windless or windy outdoor environment. Plants within each environment received either periodic seismic (shaking) or thigmic (flexing or rubbing) treatment, or were left undisturbed. Productivity (dry weight) and dimensional (leaf area and stem length) growth parameters generally were reduced more by mechanical stress in the greenhouse (soybean) or outdoor-windless environment (eggplant) than in the outdoor windy environment. Outdoor exposure enhanced both stem and leaf specific weights, whereas mechanical stress enhanced only leaf specific weight. Although both forms of controlled mechanical stress tended to reduce node and internode diameters of soybean, outdoor exposure increased stem diameter.
Evaluation of SRM flex bearing materials and processes
NASA Technical Reports Server (NTRS)
Wood, T. E.
1980-01-01
Tensile, peel, and shear testing was performed on combinations of primers, adhesives, tycements and rubber compounds cured at various times and temperatures. The materials used in the fabrication of the solid rocket motor flex bearing as well as in other systems were evaluated. A compatibility study between adhesives and tycements was initiated. The flex bearing mold design was reviewed by our tooling experts.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-03
... SECURITIES AND EXCHANGE COMMISSION [Release No. 34-67938; File No. SR-CBOE-2012-093] Self-Regulatory Organizations; Chicago Board Options Exchange, Incorporated; Notice of Filing and Immediate Effectiveness of a Proposed Rule Change Related to AIM, SAM, FLEX AIM, FLEX SAM and FLEX Electronic RFQs September 27, 2012. Pursuant to Section 19(b)(1)...
2002-11-14
KENNEDY SPACE CENTER, FLA. -- Workers on Launch Pad 39A perform checks on Endeavour's oxygen flex hose fitting through manual inspection and using helium detectors. Visual inspection found a deformity in the flex line braid where it connects to rigid tubing. The entire flex hose assembly and bulkhead fitting were removed early today, and work is under way to complete the installation of a replacement.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-12
... entered by the Submitting TPH during the RFQ Reaction Period. The ``RFQ Reaction Period'' is the period of... Response and Reaction Periods.\\19\\ When trading moves to the enhanced System, FLEX Orders may not be... to enter a FLEX Order during the RFQ Response and Reaction Periods, the FLEX Order will be rejected...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-29
... the FLEX electronic book and to the FLEX electronic RFQ process, and (v) include a description of...\\ currently resting in the electronic book in the particular series to be traded.\\8\\ Resting FLEX Orders may only be entered in the electronic book as ``day orders'' and are cancelled at the close of each trade...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-14
... System for the day and FLEX Orders \\7\\ may be entered directly into the FLEX electronic book throughout... the electronic book as ``day orders'' and are cancelled at the close of each trade day if unexecuted. Therefore, there would be no orders resting in the book from the prior day. Under the proposal, FLEX Option...
Real-Time and High-Fidelity Simulation Environment for Autonomous Ground Vehicle Dynamics
2013-08-01
ENGINEERING AND TECHNOLOGY SYMPOSIUM (GVSETS), SET FOR AUG. 21-22, 2013 14. ABSTRACT briefing charts 15. SUBJECT TERMS 16. SECURITY CLASSIFICATION OF: 17...EDL & Aero-Flight DSENDS Airships Planetary & Terrain models SimScape Simulation framework Dshell Flex & Multibody dynamics DARTS 3D...7 DARTS Rigid/Flexible Real-Time Multibody Dynamics Engine Recipient of the NASA Software of the Year Award. Abhinandan Jain, "Robot and
Alternative display and interaction devices
NASA Technical Reports Server (NTRS)
Bolas, M. T.; McDowall, I. E.; Mead, R. X.; Lorimer, E. R.; Hackbush, J. E.; Greuel, C.
1995-01-01
While virtual environment systems are typically thought to consist of a head mounted display and a flex-sensing glove, alternative peripheral devices are beginning to be developed in response to application requirements. Three such alternatives are discussed: fingertip sensing gloves, fixed stereoscopic viewers, and counterbalanced head mounted displays. A subset of commercial examples that highlight each alternative is presented as well as a brief discussion of interesting engineering and implementation issues.
NextFlex Flexible Hybrid Electronics Manufacturing
2016-10-01
Defense AT&L: September-October 2016 32 ADVANCED MANUFACTURING N NextFlex Flexible Hybrid Electronics Manufacturing Eric Forsythe, Ph.D. Benjamin...New York, in both Physics and Chemistry, where he worked on electronic interfaces and carrier transport in organic light-emitting devices in...Ohio. extFlex, America’s Flexible Hybrid Electronics Manu- facturing Innovation Institute, is a program formed out of a cooperative agreement awarded
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-05
... flex-hoses of the crew oxygen system installed under the oxygen mask stowage boxes in the flight deck... results from reports of low-pressure flex- hoses of the crew oxygen system that burned through due to... prevent inadvertent electrical current, which can cause the low-pressure flex-hoses of the crew oxygen...
An object simulation model for modeling hypothetical disease epidemics – EpiFlex
Hanley, Brian
2006-01-01
Background EpiFlex is a flexible, easy to use computer model for a single computer, intended to be operated by one user who need not be an expert. Its purpose is to study in-silico the epidemic behavior of a wide variety of diseases, both known and theoretical, by simulating their spread at the level of individuals contracting and infecting others. To understand the system fully, this paper must be read together in conjunction with study of the software and its results. EpiFlex is evaluated using results from modeling influenza A epidemics and comparing them with a variety of field data sources and other types of modeling. EpiFlex is an object-oriented Monte Carlo system, allocating entities to correspond to individuals, disease vectors, diseases, and the locations that hosts may inhabit. EpiFlex defines eight different contact types available for a disease. Contacts occur inside locations within the model. Populations are composed of demographic groups, each of which has a cycle of movement between locations. Within locations, superspreading is defined by skewing of contact distributions. Results EpiFlex indicates three phenomena of interest for public health: (1) R0 is variable, and the smaller the population, the larger the infected fraction within that population will be; (2) significant compression/synchronization between cities by a factor of roughly 2 occurs between the early incubation phase of a multi-city epidemic and the major manifestation phase; (3) if better true morbidity data were available, more asymptomatic hosts would be seen to spread disease than we currently believe is the case for influenza. These results suggest that field research to study such phenomena, while expensive, should be worthwhile. Conclusion Since EpiFlex shows all stages of disease progression, detailed insight into the progress of epidemics is possible. EpiFlex shows the characteristic multimodality and apparently random variation characteristic of real world data, but does so as an emergent property of a carefully constructed model of disease dynamics and is not simply a stochastic system. EpiFlex can provide a better understanding of infectious diseases and strategies for response. PMID:16928271
Self-shielding flex-circuit drift tube, drift tube assembly and method of making
Jones, David Alexander
2016-04-26
The present disclosure is directed to an ion mobility drift tube fabricated using flex-circuit technology in which every other drift electrode is on a different layer of the flex-circuit and each drift electrode partially overlaps the adjacent electrodes on the other layer. This results in a self-shielding effect where the drift electrodes themselves shield the interior of the drift tube from unwanted electro-magnetic noise. In addition, this drift tube can be manufactured with an integral flex-heater for temperature control. This design will significantly improve the noise immunity, size, weight, and power requirements of hand-held ion mobility systems such as those used for explosive detection.
A comparative study of the time performance between NINO and FlexToT ASICs
NASA Astrophysics Data System (ADS)
Sarasola, I.; Nemallapudi, M. V.; Gundacker, S.; Sánchez, D.; Gascón, D.; Rato, P.; Marín, J.; Auffray, E.
2017-04-01
Universitat de Barcelona (UB) and CIEMAT have designed the FlexToT ASIC for the front-end readout of SiPM-based scintillator detectors. This ASIC is aimed at time of flight (ToF) positron emission tomography (PET) applications. In this work we have evaluated the time performance of the FlexToT v2 ASIC compared to the NINO ASIC, a fast ASIC developped at CERN. NINO electronics give 64 ps sigma for single-photon time resolution (SPTR) and 93 ps FWHM for coincidence time resolution (CTR) with 2 × 2 × 5 mm3 LSO:Ce,Ca crystals and S13360-3050CS SiPMs. Using the same SiPMs and crystals, the FlexToT v2 ASIC yields 91 ps sigma for SPTR and 123 ps FWHM for CTR. Despite worse time performace than NINO, FlexToT v2 features lower power consumption (11 vs. 27 mW/ch) and linear ToT energy measurement.
Measurement of Flexed Posture for Flexible Mono-Tread Mobile Track
NASA Astrophysics Data System (ADS)
Kinugasa, Tetsuya; Akagi, Tetsuya; Ishii, Kuniaki; Haji, Takafumi; Yoshida, Koji; Amano, Hisanori; Hayashi, Ryota; Tokuda, Kenichi; Iribe, Masatsugu; Osuka, Koichi
We have proposed Flexible Mono-tread mobile Track (FMT) as a mobile mechanism on rough terrain for rescue activity, environmental investigation and planetary explorer, etc. Generally speaking, one has to teleoperate robots under invisible condition. In order to operate the robots skillfully, it is necessary to detect not only condition around the robots and its position but also posture of the robots at any time. Since flexed posture of FMT decides turning radius and direction, it is important to know its posture. FMT has vertebral structure composed of vertebrae as rigid body and intervertebral disks made by flexible devices such as rubber cylinder and spring. Since the intervertebral disks flex in three dimension, traditional sensors such as potentiometers, rotary encoders and range finders can hardly use for measurement of its deformation. The purpose of the paper, therefore, is to measure flexed posture of FMT using a novel flexible displacement sensor. We prove that the flexed posture of FMT with five intervertebral disks can be detected through experiment.
Predicting Real-Valued Protein Residue Fluctuation Using FlexPred.
Peterson, Lenna; Jamroz, Michal; Kolinski, Andrzej; Kihara, Daisuke
2017-01-01
The conventional view of a protein structure as static provides only a limited picture. There is increasing evidence that protein dynamics are often vital to protein function including interaction with partners such as other proteins, nucleic acids, and small molecules. Considering flexibility is also important in applications such as computational protein docking and protein design. While residue flexibility is partially indicated by experimental measures such as the B-factor from X-ray crystallography and ensemble fluctuation from nuclear magnetic resonance (NMR) spectroscopy as well as computational molecular dynamics (MD) simulation, these techniques are resource-intensive. In this chapter, we describe the web server and stand-alone version of FlexPred, which rapidly predicts absolute per-residue fluctuation from a three-dimensional protein structure. On a set of 592 nonredundant structures, comparing the fluctuations predicted by FlexPred to the observed fluctuations in MD simulations showed an average correlation coefficient of 0.669 and an average root mean square error of 1.07 Å. FlexPred is available at http://kiharalab.org/flexPred/ .
Flex Robotic System in transoral robotic surgery: The first 40 patients.
Mattheis, Stefan; Hasskamp, Pia; Holtmann, Laura; Schäfer, Christina; Geisthoff, Urban; Dominas, Nina; Lang, Stephan
2017-03-01
The Flex Robotic System is a new robotic device specifically developed for transoral robotic surgery (TORS). We performed a prospective clinical study, assessing the safety and efficacy of the Medrobotics Flex Robotic System. A total of 40 patients required a surgical procedure for benign lesions (n = 30) or T1 and T2 carcinomas (n = 10). Access and visualization of different anatomic subsites were individually graded by the surgeon. Setup times, access and visualization times, surgical results, as well as adverse events were documented intraoperatively. The lesions could be exposed and visualized properly in 38 patients (95%) who went on to have a surgical procedure performed with the Flex Robotic System, which were intraoperatively evaluated as successful. No serious adverse events occurred. Lesions in the oropharynx, hypopharynx, or supraglottic larynx could be successfully resected using the Flex Robotic System, thus making the system a safe and effective tool in transoral robotic surgery. © 2016 Wiley Periodicals, Inc. Head Neck 39: 471-475, 2017. © 2016 Wiley Periodicals, Inc.
2002-11-14
KENNEDY SPACE CENTER, FLA. -- Workers on Launch Pad 39A remove Endeavour's oxygen flex hose from the mid-body to inspect it for the source of an oxygen leak. Visual inspection found a deformity in the flex line braid where it connects to rigid tubing. Manual inspection and helium detectors identified the flex hose as the source of the oxygen leak. Work is under way to complete the installation of a replacement.
STS-113 workers work on oxygen leak in Endeavor's mid-body
NASA Technical Reports Server (NTRS)
2002-01-01
KENNEDY SPACE CENTER, FLA. -- Workers on Launch Pad 39A perform checks on Endeavour?s oxygen flex hose fitting through manual inspection and using helium detectors. Visual inspection found a deformity in the flex line braid where it connects to rigid tubing. The entire flex hose assembly and bulkhead fitting were removed early today, and work is under way to complete the installation of a replacement.
Ali, Mohamed A; Kobashi, Hidenaga; Kamiya, Kazutaka; Igarashi, Akihito; Miyake, Toshiyuki; Elewa, Mohamed Ehab M; Komatsu, Mari; Shimizu, Kimiya
2014-12-01
To compare postoperative astigmatic correction between femtosecond lenticule extraction (FLEx) and wavefront-guided LASIK in eyes with myopic astigmatism. Fifty-eight eyes of 41 patients undergoing FLEx and 49 eyes of 29 patients undergoing wavefront-guided LASIK to correct myopic astigmatism were examined. Visual acuity, cylindrical refraction, predictability of the astigmatic correction, and astigmatic vector components were compared between groups 6 months after surgery. There was no statistically significant difference in manifest cylindrical refraction (P = .08) or percentage of eyes within ± 0.50 diopter (D) of its refraction (P = .11) between the surgical procedures. The index of success in FLEx was statistically significantly better than that of wavefront-guided LASIK (P = .02), although there was no significant difference between the groups in other indices (eg, surgically induced astigmatism, target-induced astigmatism, astigmatic correction index, angle of error, difference vector, and flattening index). Subgroup analysis showed that FLEx had a better index of success (P = .02) and difference vector (P = .04) than wavefront-guided LASIK in the low cylinder subgroup; the angle of error in FLEx was significantly smaller than that of wavefront-guided LASIK in the moderate cylinder subgroup (P = .03). Both FLEx and wavefront-guided LASIK worked well for the correction of myopic astigmatism by the 6-month follow-up visit. Although FLEx had a better index of success than wavefront-guided LASIK when using vector analysis, it appears equivalent to wavefront-guided LASIK in terms of visual acuity and the correction of astigmatism. Copyright 2014, SLACK Incorporated.
Abdominal MRI at 3.0 T: LAVA-Flex compared with conventional fat suppression T1-weighted images.
Li, Xing Hui; Zhu, Jiang; Zhang, Xiao Ming; Ji, Yi Fan; Chen, Tian Wu; Huang, Xiao Hua; Yang, Lin; Zeng, Nan Lin
2014-07-01
To study liver imaging with volume acceleration-flexible (LAVA-Flex) for abdominal magnetic resonance imaging (MRI) at 3.0 T and compare the image quality of abdominal organs between LAVA-Flex and fast spoiled gradient-recalled (FSPGR) T1-weighted imaging. Our Institutional Review Board approval was obtained in this retrospective study. Sixty-nine subjects had both FSPGR and LAVA-Flex sequences. Two radiologists independently scored the acquisitions for image quality, fat suppression quality, and artifacts and the values obtained were compared with the Wilcoxon signed rank test. According to the signal intensity (SI) measurements, the uniformity of fat suppression, the contrast between muscle and fat and normal liver and liver lesions were compared by the paired t-test. The liver and spleen SI on the fat-only phase were analyzed in the fatty liver patients. Compared with FSPGR imaging, LAVA-Flex images had better and more homogenous fat suppression and lower susceptibility artifact (qualitative scores: 4.70 vs. 4.00, 4.86% vs. 7.14%, 4.60 and 4.10, respectively). The contrast between muscle and fat and between the liver and pathologic lesions was significantly improved on the LAVA-Flex sequence. The contrast value of the fatty liver and spleen was higher than that of the liver and spleen. The LAVA-Flex sequence offers superior and more homogenous fat suppression of the abdomen than does the FSPGR sequence. The fat-only phase can be a simple and effective method of assessing fatty liver. © 2013 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Tadesse, Melkie Getnet; Dumitrescu, Delia; Loghin, Carmen; Chen, Yan; Wang, Lichuan; Nierstrasz, Vincent
2018-03-01
Electroluminescence (EL) is the property of a semiconductor material pertaining to emitting light in response to an electrical current or a strong electric field. The purpose of this paper is to develop a flexible and lightweight EL device. Thermogravimetric analysis (TGA) was conducted to observe the thermal degradation behavior of NinjaFlex. Poly(3,4-ethylenedioxythiophene):poly(styrene sulfonic acid)—PEDOT:PSS—with ethylene glycol (EG) was coated onto polyester fabric where NinjaFlex was placed onto the coated fabric using three-dimensional (3D) printing and phosphor paste, and BendLay filaments were subsequently coated via 3D printing. Adhesion strength and flexibility of the 3D-printed NinjaFlex on textile fabrics were investigated. The TGA results of the NinjaFlex depict no weight loss up to 150°C and that the NinjaFlex was highly conductive with a surface resistance value of 8.5 ohms/sq.; the coated fabric exhibited a uniform surface appearance as measured and observed by using four-probe measurements and scanning electron microscopy, respectively, at 60% PEDOT:PSS. The results of the adhesion test showed that peel strengths of 4160 N/m and 3840 N/m were recorded for polyester and cotton specimens, respectively. No weight loss was recorded following three washing cycles of NinjaFlex. The bending lengths were increased by only a factor of 0.082 and 0.577 for polyester and cotton samples at 0.1-mm thickness, respectively; this remains sufficiently flexible to be integrated into textiles. The prototype device emitted light with a 12-V alternating current power supply.
Evaluating the Ergonomics of Flexible Ureteroscopy.
Ludwig, Wesley W; Lee, Gyusung; Ziemba, Justin B; Ko, Joan S; Matlaga, Brian R
2017-10-01
To date, the ergonomics of flexible ureteroscopy (URS) have not been well described. We performed a study to assess the biomechanical stresses on urologists performing URS and to investigate the effect of ureteroscope type on these parameters. Electromyography (EMG) was used to quantify the activation level of muscle groups involved in URS. Surface EMG electrodes (Delsys, Boston, MA) were placed on the right and left thenar, flexor carpi ulnaris (FCU), extensor carpi ulnaris (ECU), biceps, triceps, and deltoid. Three endoscopes were studied: single-use digital (Boston Scientific LithoVue), reusable digital (Karl Storz Flex-X c ), and reusable fiber-optic (Karl Storz Flex-X 2 ). Each ureteroscope was used to perform a set sequence of navigation and procedural tasks in a training model. EMG data were processed and normalized to compare the maximum voluntary contractions between muscle groups. Cumulative muscular workload (CMW) and average muscular work per second (AWS) were used for comparative analysis. For navigational tasks, CMW and AWS were greatest for the ECU, followed in descending order by right and left thenar, FCU, biceps, deltoid, and triceps. For procedural tasks, CMW and AWS were greatest for the right thenar, followed in descending order by the left thenar, ECU, FCU, triceps, biceps, and deltoid. During navigational tasks, both LithoVue and Flex-X c had lower CMWs for every muscle group than Flex-X 2 (p < 0.05). LithoVue and Flex-X c had similar AWS and both were lower than Flex-X 2 for the right thenar, ECU, biceps, and deltoid activation (p < 0.05). During procedural tasks, both LithoVue and Flex-X c had lower CMWs and AWS for right and left thenar, ECU, and biceps than Flex-X 2 (p < 0.05). This study provides the first description of EMG-measured ergonomics of URS. Both the single-use and reusable digital ureteroscopes have similar profiles, and both have significantly better ergonomic metrics than the reusable fiber-optic ureteroscope.
NASA Technical Reports Server (NTRS)
Pratt, Terrence W.
1987-01-01
PISCES 2 is a programming environment and set of extensions to Fortran 77 for parallel programming. It is intended to provide a basis for writing programs for scientific and engineering applications on parallel computers in a way that is relatively independent of the particular details of the underlying computer architecture. This user's manual provides a complete description of the PISCES 2 system as it is currently implemented on the 20 processor Flexible FLEX/32 at NASA Langley Research Center.
ERIC Educational Resources Information Center
Flaum-Horvath, Shannon; Marchand-Martella, Nancy E.; Martella, Ronald C.; Kauppi, Cassondra
2017-01-01
This study examined the effects of the SRA FLEX Literacy (FLEX) program provided to 44 middle school students considered at risk for reading failure as compared to their peers who were not at risk in reading (N = 197) who received instruction in the Holt Elements of Literature series. Two outcome measures were used to judge the effects of the…
Leite-Silva, Vânia R; Liu, David C; Sanchez, Washington Y; Studier, Hauke; Mohammed, Yousuf H; Holmes, Amy; Becker, Wolfgang; Grice, Jeffrey E; Benson, Heather Ae; Roberts, Michael S
2016-05-01
We assessed the effects of flexing and massage on human skin penetration and toxicity of topically applied coated and uncoated zinc oxide nanoparticles (˜75 nm) in vivo. Noninvasive multiphoton tomography with fluorescence lifetime imaging was used to evaluate the penetration of nanoparticles through the skin barrier and cellular apoptosis in the viable epidermis. All nanoparticles applied to skin with flexing and massage were retained in the stratum corneum or skin furrows. No significant penetration into the viable epidermis was seen and no cellular toxicity was detected. Exposure of normal in vivo human skin to these nanoparticles under common in-use conditions of flexing or massage is not associated with significant adverse events.
CABS-flex 2.0: a web server for fast simulations of flexibility of protein structures.
Kuriata, Aleksander; Gierut, Aleksandra Maria; Oleniecki, Tymoteusz; Ciemny, Maciej Pawel; Kolinski, Andrzej; Kurcinski, Mateusz; Kmiecik, Sebastian
2018-05-14
Classical simulations of protein flexibility remain computationally expensive, especially for large proteins. A few years ago, we developed a fast method for predicting protein structure fluctuations that uses a single protein model as the input. The method has been made available as the CABS-flex web server and applied in numerous studies of protein structure-function relationships. Here, we present a major update of the CABS-flex web server to version 2.0. The new features include: extension of the method to significantly larger and multimeric proteins, customizable distance restraints and simulation parameters, contact maps and a new, enhanced web server interface. CABS-flex 2.0 is freely available at http://biocomp.chem.uw.edu.pl/CABSflex2.
Realization of the electrical Sentinel 4 detector integration
NASA Astrophysics Data System (ADS)
Hermsen, M.; Hohn, R.; Skegg, M.; Woffinden, C.; Reulke, R.
2017-09-01
The detectors of the Sentinel 4 multi spectral imager are operated in flight at 215K while the analog electronics is operated at ambient temperature. The detector is cooled by means of a radiator. For thermal reasons no active component has been allowed in the cooled area closest to the detector as the passive radiator is restricted in its size. For thermal decoupling of detector and electronics a long distance between detector and electronics is considered ideal as thermal conductivity decreases with the length of the connection. In contradiction a short connection between detector and electronics is ideal for the electronic signals. Only a short connection ensures the signal integrity of both the weak detector output signal but similarly also the clock signals for driving the detector. From a mechanical and thermal point of view the connection requires a certain minimum length. The selected solution serves all these needs but had to approach the limits of what is electrically, mechanically and thermally feasible. In addition, shielding from internal (self distortion) and external distorting signals has to be realized for the connection between FEE(Front End Electronics) and detectors. At the time of the design of the flex it was not defined whether the mechanical structure between FEE and FPA (Focal Plane Assembly) would act as a shielding structure. The physical separation between CCD detector and the Front-end Electronics, the adverse EMI environment in which the instrument will be operated in (the location of the instrument on the satellite is in vicinity to a down-link K-band communication antenna of the S/C) require at least the video output signals to be shielded. Both detectors (a NIR and a UVVIS detector) are sensitive to contamination and difficult to be cleaned in case of any contamination. This brings up extreme cleanliness requirements for the detector in manufacturing and assembly. Effectively the detector has to be kept in an ISO 5 environment and additionally humidity has to be avoided - which does not comply with the usual clean-room atmosphere. This paper describes how in Sentinel 4 the given challenges have been overcome, how the limited load drive capability of the detector component has been considered on a flex length of about 20 cm (7.87 in) and how EMC shielding of the highly sensitive analog signals of the detector has been realized. Also covered are design/manufacturing aspects and a glance on testing results is provided
Zhu, Kaixian; Aouf, Sami; Roisman, Gabriel; Escourrou, Pierre
2016-01-01
Study Objectives: Pressure-relief features are aimed at improving the patient's comfort during continuous positive airway pressure (CPAP) treatment for obstructive sleep apnea. The objective of this study was to determine the effect of these therapy features on fixed CPAP and autotitrating CPAP (APAP) treatment efficacy. Methods: Seven pressure-relief features applied by three CPAP devices were included in our study (Remstar Auto: C-Flex 3, C-Flex+ 3, A-Flex 3, P-Flex; AirSense 10: EPR 3; Prisma 20A: SoftPAP 2 and 3). In fixed CPAP, the devices were subjected to a 10-min bench-simulated obstructive apnea sequence (initial apnea-hypopnea index, AHI = 60/h) with and without pressure-relief features. In APAP, the sequence was lengthened to 4.2 h (initial AHI = 58.6/h). The residual AHI and mean/median pressure were compared with and without pressure-relief features. Results: Compared to conventional CPAP, where pressure was adjusted to be just sufficient to control the simulated obstructive events, C-Flex+ 3, P-Flex, and EPR 3 failed to normalize the breathing flow and did not reduce the AHI. The mean pressures with the three features, respectively, were 1.8, 2.6, and 2.6 cmH2O lower than the conventional CPAP. Compared to conventional APAP, similar levels of control were observed with pressure-relief features, apart from P-Flex where the delivered mean pressure was lower and residual AHI greater. The device-reported mean/median pressures in APAP with A-Flex 3, P-Flex, EPR 3, and SoftPAP 3 were higher than that measured on the bench. Conclusions: Pressure-relief features may attenuate CPAP efficacy if not adjusted for at the time of their introduction. In clinical practice, efficacy can be ensured by increasing the therapeutic pressure delivered by fixed CPAP or by enabling the pressure-relief features prior to initial pressure titration. Device-reported pressures in APAP devices with pressure relief activated may overstate delivered pressures. Citation: Zhu K, Aouf S, Roisman G, Escourrou P. Pressure-relief features of fixed and autotitrating continuous positive airway pressure may impair their efficacy: evaluation with a respiratory bench model. J Clin Sleep Med 2016;12(3):385–392. PMID:26564383
The magnitude of tissue cooling during cryotherapy with varied types of compression.
Tomchuk, David; Rubley, Mack D; Holcomb, William R; Guadagnoli, Mark; Tarno, Jason M
2010-01-01
Certified athletic trainers can choose different types of external compression (none, Flex-i-Wrap, and elastic wrap) when applying an ice bag to the body. However, which type facilitates the greatest magnitude of tissue cooling is unclear. To compare the effects of 2 common types of external compression on the magnitude of surface and intramuscular cooling during an ice-bag treatment. Randomized controlled trial. University research laboratory. Fourteen college students (10 women, 4 men; age = 22.4 +/- 1.8 years, height = 169.1 +/- 8.2 cm, mass = 73.3 +/- 18.5 kg, skinfold = 13.14 +/- 1.61 mm) with previous cryotherapy experience and a posterior lower leg skinfold equal to or less than 15 mm. On 3 different days separated by 24 to 48 hours, an ice bag was applied to the posterior lower leg surface of each participant for 30 minutes with no compression, with elastic wrap, or with Flex-i-Wrap. Posterior lower leg surface and intramuscular (2 cm) temperatures were recorded for 95 minutes. At 15 minutes, the elastic wrap produced greater surface temperature reduction than no compression (P = .03); this difference remained throughout the protocol (P range, .03 to .04). At 30 minutes, surface temperatures were 14.95 degrees C, 11.55 degrees C, and 9.49 degrees C when an ice bag was applied with no external compression, Flex-i-Wrap, and elastic wrap, respectively. Surface temperatures between Flex-i-Wrap and elastic wrap and between Flex-i-Wrap and no compression were never different. At 10 minutes, Flex-i-Wrap (P = .006) and elastic wrap (P < .001) produced greater intramuscular temperature reduction than no compression produced; these differences remained throughout the protocol. At 10 minutes, no compression, Flex-i-Wrap, and elastic wrap decreased intramuscular temperature by 1.34 degrees C, 2.46 degrees C, and 2.73 degrees C, respectively. At 25 minutes, elastic wrap (8.03 degrees C) produced greater temperature reduction than Flex-i-Wrap (6.65 degrees C) (P = .03) or no compression (4.63 degrees C) (P < .001 ). These differences remained throughout ice application and until 50 minutes after ice-bag removal. During an ice-bag application, external compression with elastic wrap was more effective than Flex-i-Wrap at reducing intramuscular tissue temperature. Elastic wraps should be used for acute injury care.
2002-11-14
KENNEDY SPACE CENTER, FLA. -- During inspections at Launch Pad 39A, an oxygen flex hose fitting (shown here) was identified as the source of an oxygen leak in Endeavour's mid-body. The leak was identified manually and using helium detectors. Visual inspection found a deformity in the flex line braid where it connects to rigid tubing. The entire flex hose assembly and bulkhead fitting were removed early today, and work is under way to complete the installation of a replacement.
STS-113 workers work on oxygen leak in Endeavor's mid-body
NASA Technical Reports Server (NTRS)
2002-01-01
KENNEDY SPACE CENTER, FLA. -- Workers on Launch Pad 39A remove Endeavour?s oxygen flex hose from the mid-body to inspect it for the source of an oxygen leak. Visual inspection found a deformity in the flex line braid where it connects to rigid tubing. Manual inspection and helium detectors identified the flex hose as the source of the oxygen leak. Work is under way to complete the installation of a replacement.
Simpsy, Gurram Samuel; Sajjan, Girija S.; Mudunuri, Padmaja; Chittem, Jyothi; Prasanthi, Nalam N. V. D.; Balaga, Pankaj
2016-01-01
Introduction: M-Wire and reciprocating motion of WaveOne and controlled memory (CM) wire) of HyFlex were the recent innovations using thermal treatment. Therefore, a study was planned to evaluate the shaping ability of reciprocating motion of WaveOne and HyFlex using cone beam computed tomography (CBCT). Methodology: Forty-five freshly extracted mandibular teeth were selected and stored in saline until use. All teeth were scanned pre- and post-operatively using CBCT (Kodak 9000). All teeth were accessed and divided into three groups. (1) Group 1 (control n = 15): Instrumented with ProTaper. (2) Group 2 (n = 15): Instrumented with primary file (8%/25) WaveOne. (3) Group 3 (n = 15): Instrumented with (4%/25) HyFlex CM. Sections at 1, 3, and 5 mm were obtained from the pre- and post-operative scans. Measurement was done using CS3D software and Adobe Photoshop software. Apical transportation and degree of straightening were measured and statistically analyzed. Results: HyFlex showed lesser apical transportation when compared to other groups at 1 and 3 mm. WaveOne showed lesser degree of straightening when compared to other groups. Conclusion: This present study concluded that all systems could be employed in routine endodontics whereas HyFlex and WaveOne could be employed in severely curved canals. PMID:27994323
Danjon, Frédéric; Khuder, Hayfa; Stokes, Alexia
2013-01-01
This study aims at assessing the influence of slope angle and multi-directional flexing and their interaction on the root architecture of Robinia pseudoacacia seedlings, with a particular focus on architectural model and trait plasticity. 36 trees were grown from seed in containers inclined at 0° (control) or 45° (slope) in a glasshouse. The shoots of half the plants were gently flexed for 5 minutes a day. After 6 months, root systems were excavated and digitized in 3D, and biomass measured. Over 100 root architectural traits were determined. Both slope and flexing increased significantly plant size. Non-flexed trees on 45° slopes developed shallow roots which were largely aligned perpendicular to the slope. Compared to the controls, flexed trees on 0° slopes possessed a shorter and thicker taproot held in place by regularly distributed long and thin lateral roots. Flexed trees on the 45° slope also developed a thick vertically aligned taproot, with more volume allocated to upslope surface lateral roots, due to the greater soil volume uphill. We show that there is an inherent root system architectural model, but that a certain number of traits are highly plastic. This plasticity will permit root architectural design to be modified depending on external mechanical signals perceived by young trees. PMID:24386227
2011-04-01
a potentially unstable single limb ( Marigold and Patla, 2002; Murray et al., 1985). In theory, adopting a more flexed posture should also lower the...when knowingly traversing slippery terrain ( Marigold and Patla). Despite minimal differences in temporal-spatial values and kinematics for the two...Walking in Healthy Individuals. J. Appl. Physiol. 2008, 104, 747–755. 22 Marigold , D. S.; Patla, A. E. Strategies for Dynamic Stability During
NASA Technical Reports Server (NTRS)
Ortega, J. M.
1985-01-01
Synopses are given for NASA supported work in computer science at the University of Virginia. Some areas of research include: error seeding as a testing method; knowledge representation for engineering design; analysis of faults in a multi-version software experiment; implementation of a parallel programming environment; two computer graphics systems for visualization of pressure distribution and convective density particles; task decomposition for multiple robot arms; vectorized incomplete conjugate gradient; and iterative methods for solving linear equations on the Flex/32.
Ruan, Jesse S; El-Jawahri, Raed; Barbat, Saeed; Rouhana, Stephen W; Prasad, Priya
2008-11-01
Changes in vehicle safety design technology and the increasing use of seat-belts and airbag restraint systems have gradually changed the relative proportion of lower extremity injuries. These changes in real world injuries have renewed interest and the need of further investigation into occupant injury mechanisms and biomechanical impact responses of the knee-thigh-hip complex during frontal impacts. This study uses a detailed finite element model of the human body to simulate occupant knee impacts experienced in frontal crashes. The human body model includes detailed anatomical features of the head, neck, shoulder, chest, thoracic and lumbar spine, abdomen, pelvis, and lower and upper extremities. The material properties used in the model for each anatomic part of the human body were obtained from test data reported in the literature. The human body model used in the current study has been previously validated in frontal and side impacts. It was further validated with cadaver knee-thigh-hip impact tests in the current study. The effects of impactor configuration and flexion angle of the knee on biomechanical impact responses of the knee-thigh-hip complex were studied using the validated human body finite element model. This study showed that the knee flexion angle and the impact direction and shape of the impactors affected the injury outcomes of the knee-thigh-hip complex significantly. The 60 degrees flexed knee impact showed the least impact force, knee pressure, femoral von Mises stress, and pelvic von Mises stress but largest relative displacements of the Posterior Cruciate Ligament (PCL) and Anterior Cruciate Ligament (ACL). The 90 degrees flexed knee impact resulted in a higher impact force, knee pressure, femoral von Mises stress, and pelvic von Mises stress; but smaller PCL and ACL displacements. Stress distributions of the patella, femur, and pelvis were also given for all the simulated conditions.
STS-113 workers work on oxygen leak in Endeavor's mid-body
NASA Technical Reports Server (NTRS)
2002-01-01
KENNEDY SPACE CENTER, FLA. -- During inspections at Launch Pad 39A, an oxygen flex hose fitting (shown here) was identified as the source of an oxygen leak in Endeavour's mid-body. The leak was identified manually and using helium detectors. Visual inspection found a deformity in the flex line braid where it connects to rigid tubing. The entire flex hose assembly and bulkhead fitting were removed early today, and work is under way to complete the installation of a replacement.
Joint with application in electrochemical devices
Weil, K Scott [Richland, WA; Hardy, John S [Richland, WA
2010-09-14
A joint for use in electrochemical devices, such as solid oxide fuel cells (SOFCs), oxygen separators, and hydrogen separators, that will maintain a hermetic seal at operating temperatures of greater than 600.degree. C., despite repeated thermal cycling excess of 600.degree. C. in a hostile operating environment where one side of the joint is continuously exposed to an oxidizing atmosphere and the other side is continuously exposed to a wet reducing gas. The joint is formed of a metal part, a ceramic part, and a flexible gasket. The flexible gasket is metal, but is thinner and more flexible than the metal part. As the joint is heated and cooled, the flexible gasket is configured to flex in response to changes in the relative size of the metal part and the ceramic part brought about by differences in the coefficient of thermal expansion of the metal part and the ceramic part, such that substantially all of the tension created by the differences in the expansion and contraction of the ceramic and metal parts is absorbed and dissipated by flexing the flexible gasket.
Chu, Lisa; Morrison, Katherine M; Riddell, Michael C; Raha, Sandeep; Timmons, Brian W
2018-07-01
The capacity to match carbohydrate (CHO) oxidation with CHO availability (deemed metabolic flexibility (MetFlex)) may be important for type 2 diabetes prevention. In adults, impaired MetFlex is associated with insulin resistance (IR), which can be improved with as little as 7 days of exercise. Whether this occurs similarly in children is unknown. We hypothesized that 7 consecutive days of exercise would improve MetFlex and IR in children with obesity. Twelve children (8 boys, 4 girls) completed 2 study visits before (PRE) and 2 study visits after (POST) exercise training. At visit 1, fasting blood was collected, and anthropometry and maximal oxygen uptake were assessed. At visit 2, a 13 C-enriched CHO drink was ingested before exercise (3 × 20 min) at ∼59% maximal oxygen uptake. Exogenous CHO oxidative efficiency, used as a surrogate measurement of MetFlex, was calculated from breath samples. During training, participants alternated between continuous and high-intensity interval cycling sessions at home under supervision. In spite of good training adherence, there was no improvement in MetFlex (PRE: 20.7% ± 1.8%, POST: 18.9% ± 4.9%, p = 0.22) or homeostasis model assessment of insulin resistance (PRE: 8.7 ± 4.6, POST: 8.1 ± 6.0, p = 0.51). Future research should investigate exercise volume, sex, and pubertal effects on the early responsiveness of MetFlex to exercise therapy.
Kao, Jen-Hsin; Lin, Sheng-Hsiung; Lai, Chun-Fu; Lin, Yu-Chieh; Kong, Zwe-Ling; Wong, Chih-Shung
2016-01-01
Shea nut oil triterpene concentrate is considered to have anti-inflammatory and antioxidant properties. Traditionally, it has been used to treat arthritic conditions in humans. This study aimed to investigate the effect of attenuating osteoarthritis (OA)-induced pain and joint destruction in rats by administering shea nut oil triterpene concentrate (SheaFlex75, which is more than 50% triterpenes). An anterior cruciate ligament transaction (ACLT) with medial meniscectomy (MMx) was used to induce OA in male Wistar rats. Different doses of SheaFlex75 (111.6 mg/kg, 223.2 mg/kg, and 446.4 mg/kg) were then intragastrically administered daily for 12 weeks after surgery. Body weight and the width of the knee joint were measured weekly. Additionally, incapacitance tests were performed at weeks 2, 4, 6, 8, 10 and 12 to measure the weight bearing of the hind limbs, and the morphology and histopathology of the medial femoral condyles were examined and were evaluated using the Osteoarthritis Research Society International (OARSI) scoring system. This study showed that SheaFlex75 reduced the swelling of the knee joint with OA and rectified its weight bearing after ACLT plus MMx surgery in rats. Treatment with SheaFlex75 also decreased ACLT plus MMx surgery-induced knee joint matrix loss and cartilage degeneration. SheaFlex75 relieves the symptoms of OA and protects cartilage from degeneration. SheaFlex75 thus has the potential to be an ideal nutraceutical supplement for joint protection, particularly for injured knee joints.
Ducloy-Bouthors, A S; Davette, M; Le Fahler, G; Devos, P; Depret-Mosser, S; Krivosic-Horber, R
2004-04-01
Hip-flexed postures enlarging the pelvic diameter are used to improve the obstetric course of labour. Although most investigations show that lateral and sitting positions do not affect the spread of epidural analgesia, the effect of recently introduced hip-flexed postures has yet to be confirmed. This prospective randomised study included 93 parturients. Ropivacaine 0.1% 12 mL plus sufentanil 0.5 micrograms/mL was administered epidurally over a period of 6 min in one of four postures: sitting, right hip-flexed left lateral position, left hip-flexed right lateral position and supine 30 degrees lateral tilt as a control group. Left and right cephalad and sacral epidural spread were measured every 2 min over a period of 30 min. Pain relief, motor blockade and maternal and fetal side effects were noted. The total epidural spread was 15+/-0.3 dermatomes and the upper level of thermo-algesic blockade T7-T8 (range T3 to T10) in all groups. There were no differences between groups in left or right total spread or upper level of epidural blockade, time to maximal block or pain relief. There was no motor block nor any maternal or fetal side effects. The power of the study (1 - beta) was 93%. We conclude that, for the three hip-flexed postures tested, position does not influence local anaesthetic spread or symmetry of thermo-algesic blockade after induction of obstetric epidural analgesia.
Finger materials for air cushion vehicles. Volume 2: Base fabrics for finger materials
NASA Astrophysics Data System (ADS)
Schoppee, M. M.; Skelton, J.; Toney, M. M.; Klemens, W.
1984-12-01
Since the short lifetimes of seal/skirt systems on surface effect vehicles (SEV's) severely limit the long-term serviceability on such craft, a systematic study was undertaken to evaluate the effects of fabric structure on the performance of rubber/fabric skirt materials under conditions of high speed, high-curvature flexing. A series of nylon fabrics was designed and manufactured in which the fiber denier, yarn denier, yarn twist, yarn crimp, weave pattern and float length were varied, but in which the tensile strength was kept constant throughout. Each one of the fabrics was rubber-coated using the same natural rubber/polybutadiene blend and the same coating technique. A flex-testing apparatus was designed and built for flexing the rubber/fabric composite materials in air at an average radius of curvature of 0.28 in. at a cycling frequency of 15 Hz. The lifetimes in flex of the experimental series of fabrics, as indicated by the appearance of flex cracks in the rubber layer, ranged from a low of 140,000 cycles to a high of 21.7 million cycles, a range of over two orders of magnitude. Factorial analysis of the test results showed that lower yarn denier, lower yarn crimp, and shorter float length (plain weave) in the fabric substrate offer significant advantages in the ability of the fabric to withstand flexing. Design of three broad fabrics for full-scale skirt trials on the SRN4 craft is described.
VIEW OF THE INTERIOR OF BUILDING 125, THE STANDARDS LABORATORY. ...
VIEW OF THE INTERIOR OF BUILDING 125, THE STANDARDS LABORATORY. THE PRIMARY FUNCTION OF THE STANDARDS LABORATORY WAS TO ENSURE AND IMPLEMENT A SYSTEM OF QUALITY CONTROL FOR INCOMING MATERIALS USED IN MANUFACTURING PROCESSES. SEVERAL ENGINEERING CONTROLS WERE USED TO ASSURE ACCURACY OF THE CALIBRATION PROCESSES INCLUDING: FLEX-FREE GRANITE TABLES, AIR LOCKED DOORS, TEMPERATURE CONTROLS, AND A SUPER-CLEAN ENVIRONMENT - Rocky Flats Plant, Standards Laboratory, Immediately north of 215A water tower & adjacent to Third Street, Golden, Jefferson County, CO
Randolph, Luc D; Palin, William M; Leloup, Gaëtane; Leprince, Julian G
2016-12-01
The mechanical properties of dental resin-based composites (RBCs) are highly dependent on filler characteristics (size, content, geometry, composition). Most current commercial materials are marketed as "nanohybrids" (i.e. filler size <1μm). In the present study, filler characteristics of a selection of RBCs were described, aiming at identifying correlations with physico-mechanical properties and testing the relevance of the current classification. Micron/sub-micron particles (> or <500nm) were isolated from 17 commercial RBCs and analyzed by laser diffractrometry and/or electron microscopy. Filler and silane content were evaluated by thermogravimetric analysis and a sedimentation technique. The flexural modulus (E flex ) and strength (σ flex ) and micro-hardness were determined by three-point bending or with a Vickers indenter, respectively. Sorption was also determined. All experiments were carried out after one week of incubation in water or 75/25 ethanol/water. Average size for micron-sized fillers was almost always higher than 1μm. Ranges for mechanical properties were: 3.7
Masdeu, Maria J.; Patel, Amit V.; Seelall, Vijay; Rapoport, David M.; Ayappa, Indu
2012-01-01
Study Objectives: Patients with obstructive sleep apnea may have difficulty exhaling against positive pressure, hence limiting their acceptance of continuous positive airway pressure (CPAP). C-Flex is designed to improve comfort by reducing pressure in the mask during expiration proportionally to expiratory airflow (3 settings correspond to increasing pressure changes). When patients use CPAP, nasal resistance determines how much higher supraglottic pressure is than mask pressure. We hypothesized that increased nasal resistance results in increased expiratory supraglottic pressure swings that could be mitigated by the effects of C-Flex on mask pressure. Design: Cohort study. Setting: Sleep center. Participants: Seventeen patients with obstructive sleep apnea/hypopnea syndrome and a mechanical model of the upper airway. Interventions: In patients on fixed CPAP, CPAP with different C-Flex levels was applied multiple times during the night. In the model, 2 different respiratory patterns and resistances were tested. Measurements and Results: Airflow, expiratory mask, and supraglottic pressures were measured on CPAP and on C-Flex. Swings in pressure during expiration were determined. On CPAP, higher nasal resistance produced greater expiratory pressure swings in the supraglottis in the patients and in the model, as expected. C-Flex 3 produced expiratory drops in mask pressure (range −0.03 to −2.49 cm H2O) but mitigated the expira-tory pressure rise in the supraglottis only during a sinusoidal respiratory pattern in the model. Conclusions: Expiratory changes in mask pressure induced by C-Flex did not uniformly transmit to the supraglottis in either patients with obstructive sleep apnea on CPAP or in a mechanical model of the upper airway with fixed resistance. Data suggest that the observed lack of expiratory drop in supraglottic pressure swings is related to dynamics of the C-Flex algorithm. Citation: Masdeu MJ; Patel AV; Seelall V; Rapoport DM; Ayappa I. The supraglottic effect of a reduction in expiratory mask pressure during continuous positive airway pressure. SLEEP 2012;35(2):263-272. PMID:22294817
Flexray - An Answer to the Challenges Faced by Spacecraft On-Board Communication Protocols
NASA Astrophysics Data System (ADS)
Gunes-Lasnet, S.; Furano, G.
2007-08-01
The current spacecraft on-board network protocols are facing challenges: They need to consume low power, to handle a high data rate, and eventually need to have real-time capabilities as well as fault-tolerance; all of this at a low cost. Meanwhile, the automotive protocols are showing ever increasing enhanced performances: the automotive industry has shown recent break-throughs in communication networks. Among them, FlexRay targets specifically the next generation of automotive applications allowing Steer-by-Wire and Brake-by- Wire. FlexRay supports a very high data rate, is fault- tolerant, has real-time capabilities, and supports both periodic and aperiodic data transfer on a single bus. Space avionics has benefited from the automotive spin- ins in the past, so could FlexRay answer the space systems demands? This paper aims at demonstrating that space avionics could profit from the use of FlexRay.
Xu, Jianwen; Li, Xinning; Lian, Jane B; Ayers, David C; Song, Jie
2009-10-01
We tested the hypothesis that synthetic composites containing a high percentage of osteoconductive biominerals well-integrated with a hydrophilic polymer matrix can be engineered to provide both the structural and biochemical framework of a viable synthetic bone substitute. FlexBone, an elastic hydrogel-mineral composite exhibiting excellent structural integration was prepared by crosslinking poly(2-hydroxyethyl methacrylate) hydrogel in the presence of 25 wt% nanocrystalline hydroxyapatite and 25 wt% tricalcium phosphate. Biologically active factors tetracycline, BMP-2/7, and RANKL that stimulate bone formation and remodeling were encapsulated into FlexBone during polymerization or via postpolymerization adsorption. SEM and dynamic mechanical analyses showed that the encapsulation of tetracycline (5.0 wt%) did not compromise the structural integrity and compressive behavior of FlexBone, which could withstand repetitive megapascal-compressive loadings and be securely press-fitted into critical femoral defects. Dose-dependent, sustained in vitro release of tetracycline was characterized by spectroscopy and bacterial inhibition. A single dose of 40 ng BMP-2/7 or 10 ng RANKL pre-encapsulated with 50 mg FlexBone, released over 1 week, was able to induce local osteogenic differentiation of myoblast C2C12 cells and osteoclastogenesis of macrophage RAW264.7 cells, respectively. With a bonelike structural composition, useful surgical handling characteristics, and tunable biochemical microenvironment, FlexBone provides an exciting opportunity for the treatment of hard-to-heal skeletal defects with minimal systemic side effects. (c) 2009 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Lin, Sheng-Hsiung; Lai, Chun-Fu; Lin, Yu-Chieh; Kong, Zwe-Ling; Wong, Chih-Shung
2016-01-01
Background Shea nut oil triterpene concentrate is considered to have anti-inflammatory and antioxidant properties. Traditionally, it has been used to treat arthritic conditions in humans. This study aimed to investigate the effect of attenuating osteoarthritis (OA)-induced pain and joint destruction in rats by administering shea nut oil triterpene concentrate (SheaFlex75, which is more than 50% triterpenes). Methods An anterior cruciate ligament transaction (ACLT) with medial meniscectomy (MMx) was used to induce OA in male Wistar rats. Different doses of SheaFlex75 (111.6 mg/kg, 223.2 mg/kg, and 446.4 mg/kg) were then intragastrically administered daily for 12 weeks after surgery. Body weight and the width of the knee joint were measured weekly. Additionally, incapacitance tests were performed at weeks 2, 4, 6, 8, 10 and 12 to measure the weight bearing of the hind limbs, and the morphology and histopathology of the medial femoral condyles were examined and were evaluated using the Osteoarthritis Research Society International (OARSI) scoring system. Results This study showed that SheaFlex75 reduced the swelling of the knee joint with OA and rectified its weight bearing after ACLT plus MMx surgery in rats. Treatment with SheaFlex75 also decreased ACLT plus MMx surgery-induced knee joint matrix loss and cartilage degeneration. Conclusion SheaFlex75 relieves the symptoms of OA and protects cartilage from degeneration. SheaFlex75 thus has the potential to be an ideal nutraceutical supplement for joint protection, particularly for injured knee joints. PMID:27583436
Development of a Thin-Film Solar Cell Interconnect for the Powersphere Concept
NASA Technical Reports Server (NTRS)
Simburger, Edward J.; Matsumoto, James H.; Giants, Thomas W.; Garcia, Alexander, III; Liu, Simon; Rawal, Suraj P.; Perry, Alan R.; Marshall, Craig; Lin, John K.; Scarborough, Stephen E.
2005-01-01
Dual junction amorphous silicon (a-Si) solar cells produced on polyimide substrate have been selected as the best candidate to produce a lightweight solar array for the PowerSphere program. The PowerSphere concept features a space-inflatable, geodetic solar array approximately 0.6 meters in diameter and capable of generating about 20W of electrical power. Trade studies of various wiring concepts and connection methods led to an interconnect design with a copper contact that wraps around the edge, to the back of the solar cell. Applying Plasma Vapor Deposited (PVD) copper film to both sides and the edge of the solar cell produces the wrap around contact. This procedure results in a contact pad on the back of the solar cell, which is then laser welded to a flex circuit material. The flex circuit is constructed of copper in a custom designed routing pattern, and then sandwiched in a Kapton insulation layer. The flex circuit then serves as the primary power distribution system between the solar cells and the spacecraft. Flex circuit material is the best candidate for the wiring harness because it allows for low force deployment of the solar cells by the inflatable hinges on the PowerSphere. An additional frame structure, fabricated and assembled by ILC Dover, will reinforce the wrap around contact-flex blanket connection, thus providing a mechanically robust solar cell interconnect for the PowerSphere multifunctional program. The PowerSphere team will use the wraparound contact design approach as the primary solution for solar cell integration and the flex blanket for power distribution.
Gravitational Effects upon Locomotion Posture
NASA Technical Reports Server (NTRS)
DeWitt, John K.; Bentley, Jason R.; Edwards, W. Brent; Perusek, Gail P.; Samorezov, Sergey
2008-01-01
Researchers use actual microgravity (AM) during parabolic flight and simulated microgravity (SM) obtained with horizontal suspension analogs to better understand the effect of gravity upon gait. In both environments, the gravitational force is replaced by an external load (EL) that returns the subject to the treadmill. However, when compared to normal gravity (N), researchers consistently find reduced ground reaction forces (GRF) and subtle kinematic differences (Schaffner et al., 2005). On the International Space Station, the EL is applied by elastic bungees attached to a waist and shoulder harness. While bungees can provide EL approaching body weight (BW), their force-length characteristics coupled with vertical oscillations of the body during gait result in a variable load. However, during locomotion in N, the EL is consistently equal to 100% body weight. Comparisons between AM and N have shown that during running, GRF are decreased in AM (Schaffner et al, 2005). Kinematic evaluations in the past have focussed on joint range of motion rather than joint posture at specific instances of the gait cycle. The reduced GRF in microgravity may be a result of differing hip, knee, and ankle positions during contact. The purpose of this investigation was to compare joint angles of the lower extremities during walking and running in AM, SM, and N. We hypothesized that in AM and SM, joints would be more flexed at heel strike (HS), mid-stance (MS) and toe-off (TO) than in N.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-14
... category is OTC options that have the same degree of customization as FLEX options. The third category... customization as FLEX options, and (iv) customized options where the strike price is expressed in percentage...
How to handle part-time, flex-time, and job-sharing employees.
Sachs, L
2001-01-01
Offering employment structures other than traditional full-time positions in your practice can help you draw excellent job applicants and also can enable you to increase morale, job satisfaction, and productivity. However, there are many decisions you must make when offering a part-time, flex-time, or job-sharing position. This article explores the pros and cons of offering alternative job structures. It suggests ways to make part-time, flex-time, or job-sharing positions work most effectively, both for the employee and for your practice. In addition, this article suggests which positions are best suited to alternative structures.
Flexure Bearing Reduces Startup Friction
NASA Technical Reports Server (NTRS)
Clingman, W. Dean
1991-01-01
Design concept for ball bearing incorporates small pieces of shim stock, wire spokes like those in bicycle wheels, or other flexing elements to reduce both stiction and friction slope. In flexure bearing, flexing elements placed between outer race of ball bearing and outer ring. Elements flex when ball bearings encounter small frictional-torque "bumps" or even larger ones when bearing balls encounter buildups of grease on inner or outer race. Flexure of elements reduce high friction slopes of "bumps", helping to keep torque between outer ring and inner race low and more nearly constant. Concept intended for bearings in gimbals on laser and/or antenna mirrors.
Kappelgaard, Anne-Marie; Mikkelsen, Søren; Knudsen, Thomas Kamp; Fuchs, Gitte Schøning
2011-01-01
Growth hormone deficiency (GHD) in children is treated with daily subcutaneous injections of GH. Poor adherence, resulting in suboptimal treatment outcomes, is common due to long-term treatment. Injection devices that are considered easy to use by patients or guardians could improve adherence. This study assessed the usability of the Norditropin FlexPro pen injector and NovoTwist needles (both Novo Nordisk A/S, Bagsvaerd, Denmark) in Japanese children and adolescents with GHD. This open-label, uncontrolled usability test included patients aged 6 to < or = 18 years with GHD currently receiving daily injections of GH with pen injectors. Patients performed repeated injections of test medium into a foam cushion. Patients or guardians completed a questionnaire on pen handling. A total of 73/74 patients (99%) rated Norditropin FlexPro easy to handle, reporting no technical complaints. In total, 60 (81%) preferred Norditropin FlexPro over their current device, with 12% preferring their current device and 7% not sure. Norditropin FlexPro was perceived as easy to use and reliable, and was well accepted and preferred over the current device for the administration of GH in children and adolescents. Patients were more confident that Norditropin FlexPro delivered the right dose compared with their current device.
A comparison of apical transportation between FlexMaster and Twisted Files rotary instruments.
Duran-Sindreu, Fernando; García, Marc; Olivieri, Juan Gonzalo; Mercadé, Montse; Morelló, Sergio; Roig, Miguel
2012-07-01
The aim of this study was to evaluate apical transportation in root canals after the use of Twisted Files (TF; SybronEndo, Orange, CA) and FlexMaster (VDW, Munich, Germany) #40/04 rotary files. A double-digital radiographic technique was used to compare apical transportation between the TF and FlexMaster systems. Each rotary system was used to instrument mesial canals from 80 extracted mandibular molars. The central axes of the file imaged before instrumentation (#15 K-file) and the master apical rotary file (#40/04) were superimposed digitally. AutoCAD 2008 (Autodesk Inc, San Rafael, CA) was used to measure apical transportation at 0.5 mm from the working length (WL). The data were analyzed using the Student's t test, and significance was set at P < .05. The mean amount of apical transportation at 0.5 mm from the WL was 0.17 ± 0.09 mm for the FlexMaster group and 0.19 ± 0.12 mm for the TF group. No statistically significant differences in apical transportation were found between the 2 groups. Under the conditions of the study, no statistically significant differences in apical transportation were observed between FlexMaster and TF rotary files. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
High-Density Superconducting Cables for Advanced ACTPol
NASA Astrophysics Data System (ADS)
Pappas, C. G.; Austermann, J.; Beall, J. A.; Duff, S. M.; Gallardo, P. A.; Grace, E.; Henderson, S. W.; Ho, S. P.; Koopman, B. J.; Li, D.; McMahon, J.; Nati, F.; Niemack, M. D.; Niraula, P.; Salatino, M.; Schillaci, A.; Schmitt, B. L.; Simon, S. M.; Staggs, S. T.; Stevens, J. R.; Vavagiakis, E. M.; Ward, J. T.; Wollack, E. J.
2016-07-01
Advanced ACTPol (AdvACT) is an upcoming Atacama Cosmology Telescope (ACT) receiver upgrade, scheduled to deploy in 2016, that will allow measurement of the cosmic microwave background polarization and temperature to the highest precision yet with ACT. The AdvACT increase in sensitivity is partly provided by an increase in the number of transition-edge sensors (TESes) per array by up to a factor of two over the current ACTPol receiver detector arrays. The high-density AdvACT TES arrays require 70 \\upmu m pitch superconducting flexible cables (flex) to connect the detector wafer to the first-stage readout electronics. Here, we present the flex fabrication process and test results. For the flex wiring layer, we use a 400-nm-thick sputtered aluminum film. In the center of the cable, the wiring is supported by a polyimide substrate, which smoothly transitions to a bare (uncoated with polyimide) silicon substrate at the ends of the cable for a robust wedge wire-bonding interface. Tests on the first batch of flex made for the first AdvACT array show that the flex will meet the requirements for AdvACT, with a superconducting critical current above 1 mA at 500 mK, resilience to mechanical and cryogenic stress, and a room temperature yield of 97 %.
High-Density Superconducting Cables for Advanced ACTPol
NASA Technical Reports Server (NTRS)
Pappas, C. G.; Austermann, J.; Beall, J. A.; Duff, S. M.; Gallardo, P. A.; Grace, E.; Henderson, S. W.; Ho, S. P.; Koopman, B. J.; Li, D.;
2016-01-01
Advanced ACTPol (AdvACT) is an upcoming Atacama Cosmology Telescope (ACT) receiver upgrade, scheduled to deploy in 2016, that will allow measure- ment of the cosmic microwave background polarization and temperature to the highest precision yet with ACT. The AdvACT increase in sensitivity is partly provided by an increase in the number of transition-edge sensors (TESes) per array by up to a factor of two over the current ACTPol receiver detector arrays. The high-density AdvACT TES arrays require 70 µ m pitch superconducting flexible cables (flex) to connect the detec- tor wafer to the first-stage readout electronics. Here, we present the flex fabrication process and test results. For the flex wiring layer, we use a 400-nm-thick sputtered alu- minum film. In the center of the cable, the wiring is supported by a polyimide substrate, which smoothly transitions to a bare (uncoated with polyimide) silicon substrate at the ends of the cable for a robust wedge wire-bonding interface. Tests on the first batch of flex made for the first AdvACT array show that the flex will meet the requirements for AdvACT, with a superconducting critical current above 1 mA at 500 mK, resilience to mechanical and cryogenic stress, and a room temperature yield of 97%.
Lehecka, B J; Edwards, Michael; Haverkamp, Ryan; Martin, Lani; Porter, Kambry; Thach, Kailey; Sack, Richard J; Hakansson, Nils A
2017-08-01
Gluteal strength plays a role in injury prevention, normal gait patterns, eliminating pain, and enhancing athletic performance. Research shows high gluteal muscle activity during a single-leg bridge compared to other gluteal strengthening exercises; however, prior studies have primarily measured muscle activity with the active lower extremity starting in 90 ° of knee flexion with an extended contralateral knee. This standard position has caused reports of hamstring cramping, which may impede optimal gluteal strengthening. The purpose of this study was to determine which modified position for the single-leg bridge is best for preferentially activating the gluteus maximus and medius. Cross-Sectional. Twenty-eight healthy males and females aged 18-30 years were tested in five different, randomized single-leg bridge positions. Electromyography (EMG) electrodes were placed on subjects' gluteus maximus, gluteus medius, rectus femoris, and biceps femoris of their bridge leg (i.e., dominant or kicking leg), as well as the rectus femoris of their contralateral leg. Subjects performed a maximal voluntary isometric contraction (MVIC) for each tested muscle prior to performing five different bridge positions in randomized order. All bridge EMG data were normalized to the corresponding muscle MVIC data. A modified bridge position with the knee of the bridge leg flexed to 135 ° versus the traditional 90 ° of knee flexion demonstrated preferential activation of the gluteus maximus and gluteus medius compared to the traditional single-leg bridge. Hamstring activation significantly decreased (p < 0.05) when the dominant knee was flexed to 135 ° (23.49% MVIC) versus the traditional 90 ° (75.34% MVIC), while gluteal activation remained similarly high (51.01% and 57.81% MVIC in the traditional position, versus 47.35% and 57.23% MVIC in the modified position for the gluteus maximus and medius, respectively). Modifying the traditional single-leg bridge by flexing the active knee to 135 ° instead of 90 ° minimizes hamstring activity while maintaining high levels of gluteal activation, effectively building a bridge better suited for preferential gluteal activation. 3.
Utah traffic lab driving simulator : user manual and flex lanes scenario development.
DOT National Transportation Integrated Search
2012-06-01
This report describes the University of Utah Traffic Lab (UTL) driving simulator, and a scenario development for Flex Lanes driving simulation. The first part describes the driving simulator in details. At the time of installation, the UTL driving si...
Utah Traffic Lab Driving Simulator : User Manual and Flex Lanes Scenario Development
DOT National Transportation Integrated Search
2012-06-01
This report describes the University of Utah Traffic Lab (UTL) driving simulator, and a scenario development for Flex Lanes driving simulation. The first part describes the driving simulator in details. At the time of installation, the UTL driving si...
Alió, J L; El Bahrawy, M; Angelov, A; Ortiz, D; Yébana, P
2017-05-01
To investigate the influence of creating a flap on the postoperative optical quality of the cornea in terms of predicted corneal curvature and Seidel aberrations after 2 modalities of femtosecond assisted corneal lenticule extraction laser for the correction of myopia and myopic astigmatism: The flapless procedure small incision lenticular extraction (SMILE) and the flap-based femtosecond lenticular extraction (FLEx). The study is a prospective consecutive non-randomised comparative interventional case series including 64 eyes with myopic or myopic astigmatism refractive errors. Patients were divided into 2 groups matched for age, sex and myopia. One group underwent SMILE treatment and the other underwent FLEx treatment. Seidel aberrations root-mean-square values were obtained with a 10mm aperture using the ATLAS 9000 topographer before surgery and 3 months after surgery. The relationship between the post-surgical corneal radius and the predicted sculpted radius were analysed in each group. The mean percentage change in the curvature radius was -2.03% in the FLEx group and -1.77% in the SMILE group (P=.655). The higher correlation for the SMILE group demonstrates a better predictability after the surgery. As regards corneal aberrations, the FLEx treatment showed a greater increase of higher order aberrations than SMILE treatment (P=.04). The mean refractive change in corneal curvature, which is indirectly related to the biomechanical response of the corneal surface after the lenticule cut and extraction, was similar after both treatments. However, the flap based FLEx procedure showed a greater degradation of the corneal optical quality in terms of induction of higher order aberrations. Copyright © 2016 Sociedad Española de Oftalmología. Publicado por Elsevier España, S.L.U. All rights reserved.
2012-01-01
Background A flexed neck posture leads to non-specific activation of the brain. Sensory evoked cerebral potentials and focal brain blood flow have been used to evaluate the activation of the sensory cortex. We investigated the effects of a flexed neck posture on the cerebral potentials evoked by visual, auditory and somatosensory stimuli and focal brain blood flow in the related sensory cortices. Methods Twelve healthy young adults received right visual hemi-field, binaural auditory and left median nerve stimuli while sitting with the neck in a resting and flexed (20° flexion) position. Sensory evoked potentials were recorded from the right occipital region, Cz in accordance with the international 10–20 system, and 2 cm posterior from C4, during visual, auditory and somatosensory stimulations. The oxidative-hemoglobin concentration was measured in the respective sensory cortex using near-infrared spectroscopy. Results Latencies of the late component of all sensory evoked potentials significantly shortened, and the amplitude of auditory evoked potentials increased when the neck was in a flexed position. Oxidative-hemoglobin concentrations in the left and right visual cortices were higher during visual stimulation in the flexed neck position. The left visual cortex is responsible for receiving the visual information. In addition, oxidative-hemoglobin concentrations in the bilateral auditory cortex during auditory stimulation, and in the right somatosensory cortex during somatosensory stimulation, were higher in the flexed neck position. Conclusions Visual, auditory and somatosensory pathways were activated by neck flexion. The sensory cortices were selectively activated, reflecting the modalities in sensory projection to the cerebral cortex and inter-hemispheric connections. PMID:23199306
Flow-controlled expiration: a novel ventilation mode to attenuate experimental porcine lung injury.
Goebel, U; Haberstroh, J; Foerster, K; Dassow, C; Priebe, H-J; Guttmann, J; Schumann, S
2014-09-01
Whereas the effects of various inspiratory ventilatory modifications in lung injury have extensively been studied, those of expiratory ventilatory modifications are less well known. We hypothesized that the newly developed flow-controlled expiration (FLEX) mode provides a means of attenuating experimental lung injury. Experimental acute respiratory distress syndrome was induced by i.v. injection of oleic acid in 15 anaesthetized and mechanically ventilated pigs. After established lung injury ([Formula: see text]ratio <27 kPa), animals were randomized to either a control group receiving volume-controlled ventilation (VCV) or a treatment group receiving VCV with additional FLEX (VCV+FLEX). At predefined times, lung mechanics and oxygenation were assessed. At the end of the experiment, the pigs were killed, and bronchoalveolar fluid and lung biopsies were taken. Expression of inflammatory cytokines was analysed in lung tissue and bronchoalveolar fluid. Lung injury score was determined on the basis of stained tissue samples. Compared with the control group (VCV; n=8), the VCV+FLEX group (n=7) demonstrated greater dynamic lung compliance and required less PEEP at comparable [Formula: see text] (both P<0.05), had lower regional lung wet-to-dry ratios and lung injury scores (both P<0.001), and showed less thickening of alveolar walls (an indicator of interstitial oedema) and de novo migration of macrophages into lung tissue (both P<0.001). The newly developed FLEX mode is able to attenuate experimental lung injury. FLEX could provide a novel means of lung-protective ventilation. © The Author [2014]. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Chen, Xiang; He, Si-Min; Bu, Dongbo; Zhang, Fa; Wang, Zhiyong; Chen, Runsheng; Gao, Wen
2008-09-15
RNA secondary structures with pseudoknots are often predicted by minimizing free energy, which is proved to be NP-hard. Due to kinetic reasons the real RNA secondary structure often has local instead of global minimum free energy. This implies that we may improve the performance of RNA secondary structure prediction by taking kinetics into account and minimize free energy in a local area. we propose a novel algorithm named FlexStem to predict RNA secondary structures with pseudoknots. Still based on MFE criterion, FlexStem adopts comprehensive energy models that allow complex pseudoknots. Unlike classical thermodynamic methods, our approach aims to simulate the RNA folding process by successive addition of maximal stems, reducing the search space while maintaining or even improving the prediction accuracy. This reduced space is constructed by our maximal stem strategy and stem-adding rule induced from elaborate statistical experiments on real RNA secondary structures. The strategy and the rule also reflect the folding characteristic of RNA from a new angle and help compensate for the deficiency of merely relying on MFE in RNA structure prediction. We validate FlexStem by applying it to tRNAs, 5SrRNAs and a large number of pseudoknotted structures and compare it with the well-known algorithms such as RNAfold, PKNOTS, PknotsRG, HotKnots and ILM according to their overall sensitivities and specificities, as well as positive and negative controls on pseudoknots. The results show that FlexStem significantly increases the prediction accuracy through its local search strategy. Software is available at http://pfind.ict.ac.cn/FlexStem/. Supplementary data are available at Bioinformatics online.
Ishii, Rie; Shimizu, Kimiya; Igarashi, Akihito; Kobashi, Hidenaga; Kamiya, Kazutaka
2015-01-01
To compare the influence of femtosecond lenticule extraction (FLEx) and small incision lenticule extraction (SMILE) on corneal nerve density and the ocular surface for equivalent degrees of correction of myopia. Sixty eyes of 30 patients (8 males and 22 females, mean age: 31.0 ± 6.0 years) were included in the study. The patients underwent FLEx in 1 eye and SMILE in the other eye by random assignment. Subbasal nerve density was measured using confocal microscopy preoperatively and at 1 week, 1 and 3 months, and 1 year postoperatively. Ocular surface parameters such as Schirmer's test results, tear film break-up time, and corneal sensation were performed preoperatively and at 1 and 3 months postoperatively. In the FLEx group, subbasal nerve density was 18,390 ± 6,090 µm/mm(2) preoperatively and 5,770 ± 3,490 µm/mm(2) at 1 year postoperatively (P < .001, Dunnett's test). In the SMILE group, subbasal nerve density was 16,810 ± 6,220 µm/mm(2) preoperatively and 11,870 ± 8,200 µm/mm(2) at 1 year postoperatively (P = .21). The decrease in corneal nerve density was significantly less after SMILE than after FLEx at all postoperative visits (Mann-Whitney U test, P < .05). FLEx resulted in a significant decrease in Schirmer's test results, tear film break-up time, and corneal sensation at all postoperative visits, whereas SMILE induced no significant changes in these parameters (P > .05). There was less damage to the sub-basal nerve plexus of the cornea and less effect on the ocular surface parameters after SMILE than after FLEx. Copyright 2015, SLACK Incorporated.
Air toxic emissions from passenger cars operating on ethanol blend gasoline
Emissions of gaseous and particulate contaminants have been characterized during the operation of two flex-fuel and one non-flex-fueled light-duty vehicle. These vehicles were operated on a chassis dynamometer using a driving cycle representative of urban conditions while burning...
Detailed Results from the Flame Extinguishment Experiment (FLEX) March 2009 to December 2011
NASA Technical Reports Server (NTRS)
Dietrich, Daniel L.; Ferkul, Paul V.; Bryg, Victoria M.; Nayagam, M. Vedha; Hicks, Michael C.; Williams, Forman A.; Dryer, Frederick L.; Shaw, Benjamin D.; Choi, Mun Y.; Avedisian, C. Thomas
2015-01-01
The Flame Extinguishment Experiment (FLEX) program is a continuing set of experiments on droplet combustion, performed employing the Multi-User Droplet Combustion Apparatus (MDCA), inside the chamber of the Combustion Integrated Rack (CIR), which is located in the Destiny module of the International Space Station (ISS). This report describes the experimental hardware, the diagnostic equipment, the experimental procedures, and the methods of data analysis for FLEX. It also presents the results of the first 284 tests performed. The intent is not to interpret the experimental results but rather to make them available to the entire scientific community for possible future interpretations.
A generic multi-flex-body dynamics, controls simulation tool for space station
NASA Technical Reports Server (NTRS)
London, Ken W.; Lee, John F.; Singh, Ramen P.; Schubele, Buddy
1991-01-01
An order (n) multiflex body Space Station simulation tool is introduced. The flex multibody modeling is generic enough to model all phases of Space Station from build up through to Assembly Complete configuration and beyond. Multibody subsystems such as the Mobile Servicing System (MSS) undergoing a prescribed translation and rotation are also allowed. The software includes aerodynamic, gravity gradient, and magnetic field models. User defined controllers can be discrete or continuous. Extensive preprocessing of 'body by body' NASTRAN flex data is built in. A significant aspect, too, is the integrated controls design capability which includes model reduction and analytic linearization.
Thomas, Vinoy; Jayabalan, Muthu
2009-04-01
Development of new generation high flex life polyurethane urea (HFL18-PU) with appropriate elastic modulus, biocompatibility, blood compatibility, resistant to calcification, and biodurability for the long-term use as cardiac device is still a challenge. This study reports the development of a fully aliphatic, ether-free physically cross-linked and low elastic modulus (6.841 +/- 0.27 MPa) polyurethane urea having in vivo biostability, in vivo biocompatibility and high flex-life (721 +/- 30 million cycles) that can satisfy the requirements for the fabrication of tri-leaflet heart valve. Copyright 2008 Wiley Periodicals, Inc.
Watching individual molecules flex within lipid membranes using SERS
NASA Astrophysics Data System (ADS)
Taylor, Richard W.; Benz, Felix; Sigle, Daniel O.; Bowman, Richard W.; Bao, Peng; Roth, Johannes S.; Heath, George R.; Evans, Stephen D.; Baumberg, Jeremy J.
2014-08-01
Interrogating individual molecules within bio-membranes is key to deepening our understanding of biological processes essential for life. Using Raman spectroscopy to map molecular vibrations is ideal to non-destructively `fingerprint' biomolecules for dynamic information on their molecular structure, composition and conformation. Such tag-free tracking of molecules within lipid bio-membranes can directly connect structure and function. In this paper, stable co-assembly with gold nano-components in a `nanoparticle-on-mirror' geometry strongly enhances the local optical field and reduces the volume probed to a few nm3, enabling repeated measurements for many tens of minutes on the same molecules. The intense gap plasmons are assembled around model bio-membranes providing molecular identification of the diffusing lipids. Our experiments clearly evidence measurement of individual lipids flexing through telltale rapid correlated vibrational shifts and intensity fluctuations in the Raman spectrum. These track molecules that undergo bending and conformational changes within the probe volume, through their interactions with the environment. This technique allows for in situ high-speed single-molecule investigations of the molecules embedded within lipid bio-membranes. It thus offers a new way to investigate the hidden dynamics of cell membranes important to a myriad of life processes.
Office type's association to employees' welfare: Three studies.
Danielsson, Christina Bodin
2016-08-12
The workplace is important for employees' daily life and well-being. This article investigates exploratory the office design's role for employees' welfare from different perspectives. By comparing different studies of the office, type's influence on different factors of employees' welfare the aim is to see if any common patterns exist in office design's impact. The three included studies investigate office type's association with employees' welfare by measuring its influence on: a) perception of leadership, b) sick leave, and c) job satisfaction.The sample consists of office employees from a large, national representative work environment survey that work in one of the seven identified office types in contemporary office design: (1) cell-offices; (2) shared-room offices; (3) small, (4) medium-sized and (5) large open-plan offices; (6) flex-offices and (7) combi-offices. Statistical method used is multivariate logistic and linear regression analysis with adjustment for background factors. Overall results show that shared-room office, traditional open plan offices and flex-office stand out negatively, but to different degree(s) on the different outcomes measured. This explorative comparison of different studies finds a pattern of office types that repeatedly show indications of negative influence on employees' welfare, but further studies are needed to clarify this.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-24
... carrying cases, wrist straps, screws, power supplies, nickel/ cadmium batteries, lithium/ion batteries, other batteries, antenna assemblies, audio flex assemblies, bridge flex assemblies, interplex assembly... components and materials sourced from abroad include: labels, battery adhesives, decals, Kevlar protective...
NASA Astrophysics Data System (ADS)
Yang, C.; Zheng, W.; Zhang, M.; Yuan, T.; Zhuang, G.; Pan, Y.
2016-06-01
Measurement and control of the plasma in real-time are critical for advanced Tokamak operation. It requires high speed real-time data acquisition and processing. ITER has designed the Fast Plant System Controllers (FPSC) for these purposes. At J-TEXT Tokamak, a real-time data acquisition and processing framework has been designed and implemented using standard ITER FPSC technologies. The main hardware components of this framework are an Industrial Personal Computer (IPC) with a real-time system and FlexRIO devices based on FPGA. With FlexRIO devices, data can be processed by FPGA in real-time before they are passed to the CPU. The software elements are based on a real-time framework which runs under Red Hat Enterprise Linux MRG-R and uses Experimental Physics and Industrial Control System (EPICS) for monitoring and configuring. That makes the framework accord with ITER FPSC standard technology. With this framework, any kind of data acquisition and processing FlexRIO FPGA program can be configured with a FPSC. An application using the framework has been implemented for the polarimeter-interferometer diagnostic system on J-TEXT. The application is able to extract phase-shift information from the intermediate frequency signal produced by the polarimeter-interferometer diagnostic system and calculate plasma density profile in real-time. Different algorithms implementations on the FlexRIO FPGA are compared in the paper.
Shahi, Shahriar; Yavari, Hamid R; Rahimi, Saeed; Reyhani, Mohammad F; Kamarroosta, Zahra; Abdolrahimi, Majid
2009-03-01
The aim of this study was to evaluate the effect of RaCe, FlexMaster and ProFile rotary instruments on smear layer formation by scanning electron microscopy. Eighty-four caries-free freshly extracted human single-rooted teeth were selected and divided into three groups, each containing 28 teeth. The teeth were instrumented with rotary instruments sequentially: Group A: ProFile Rotary Instruments; Group B: FlexMaster Rotary Instruments; and Group C: RaCe Rotary Instruments. Instrumentation was performed by the crown-down method and according to the manufacturer's instructions. The specimens were then examined with SEM according to Hülsmann's classification. One-way ANOVA and a post hoc Tukey test were used for statistical analysis. The results showed that there were no statistically significant differences among the three groups in the coronal third (P = 0.39), but at the apical and middle thirds there were statistically significant differences between the RaCe group and the other groups (P < 0.05). Smear layer in the RaCe group was less than that in the ProFile and FlexMaster groups, but the difference between the ProFile group and FlexMaster group was not statistically significant (P > 0.05). It was concluded that RaCe Rotary Instruments produce less smear layer than FlexMaster and ProFile Rotary Instruments.
Wang, Xiao-Bo; Yin, Yan; Miao, Yuan; Eberhardt, Ralf; Hou, Gang; Herth, Felix J; Kang, Jian
2016-11-01
Diagnosing pleural effusion is challenging, especially in patients with malignant or benign fibrothorax, which is difficult to sample using standard flexible forceps (SFF) via flex-rigid pleuroscopy. An adequate sample is crucial for the differential diagnosis of malignant fibrothorax (malignant pleural mesothelioma, metastatic lung carcinoma, etc.) from benign fibrothorax (benign asbestos pleural disease, tuberculous pleuritis, etc.). Novel biopsy techniques are required in flex-rigid pleuroscopy to improve the sample size and quality. The SB knife Jr, which is a scissor forceps that uses a mono-pole high frequency, was developed to allow convenient and accurate resection of larger lesions during endoscopic dissection (ESD). Herein, we report two patients with fibrothorax who underwent a pleural biopsy using an SB knife Jr to investigate the potential use of this tool in flex-rigid pleuroscopy when pleural lesions are difficult to biopsy via SFF. The biopsies were successful, with sufficient size and quality for definitive diagnosis. We also successfully performed adhesiolysis with the SB knife Jr in one case, and adequate biopsies were conducted. No complications were observed. Electrosurgical biopsy with the SB knife Jr during flex-rigid pleuroscopy allowed us to obtain adequate samples for the diagnosis of malignant versus benign fibrothorax, which is usually not possible with SFF. The SB knife Jr also demonstrated a potential use for pleuropulmonary adhesions.
Intra-operatively measured spastic semimembranosus forces of children with cerebral palsy.
Yucesoy, Can A; Temelli, Yener; Ateş, Filiz
2017-10-01
The knee kept forcibly in a flexed position is typical in cerebral palsy. Using a benchmark, we investigate intra-operatively if peak spastic hamstring force is measured in flexed knee positions. This tests the assumed shift of optimal length due to adaptation of spastic muscle and a decreasing force trend towards extension. Previously we measured spastic gracilis (GRA) and semitendinosus (ST) forces. Presently, we studied spastic semimembranosus (SM) and tested the following hypotheses: spastic SM forces are (1) high in flexed and (2) low in extended positions. We compared the data to those of GRA and ST to test (3) if percentages of peak force produced in flexed positions are different. During muscle lengthening surgery of 8 CP patients (9years, 4months; GMFCS levels=II-IV; limbs tested=13) isometric SM forces were measured from flexion (120°) to full extension (0°). Spastic SM forces were low in flexed knee positions (only 4.2% (3.4%) and 10.7% (9.7%) of peak force at KA=120° and KA=90° respectively, indicating less force production compared to the GRA or ST) and high in extended knee positions (even 100% of peak force at KA=0°). This indicates an absence of strong evidence for a shift of optimal muscle length of SM towards flexion. Copyright © 2017 Elsevier Ltd. All rights reserved.
USER'S GUIDE TO FLEXIBLE MEMBRANE LINER ADVISORY EXPERT SYSTEM: FLEX VERSION 3.0
The guide is a user manual for the Flexible Membrane Liner Advisory Expert System (FLEX). The system assists in determining if a proposed synthetic liner material will be chemically resistant to a proposed or anticipated leachate from a hazardous waste land disposal site. More sp...
ERIC Educational Resources Information Center
Murray, Shannon
2008-01-01
Flexible modular scheduling (flex mod)--a schedule philosophy and system that has been in place at Wausau West High School in Wausau, Wisconsin, for the last 35 years and aligns nicely with current research on student learning--is getting more and more attention from high school administrators across the country. Flexible modular scheduling was…
University of Idaho's low-speed flex fuel direct-injected 797cc two-stroke rear drive snowmobile.
DOT National Transportation Integrated Search
2012-06-01
The University of Idahos entry into the 2012 SAE Clean Snowmobile Challenge uses a Ski-Doo XP chassis with a low-speed 797 cc direct-injection two-stroke powered snowmobile modified for flex fuel use on blended ethanol fuel. A battery-less direct ...
Flex Year: A Concept to Optimize Human Resources.
ERIC Educational Resources Information Center
Wulf, Gary W.
1981-01-01
Flex Year, which was designed to provide a variety of work schedules for employees, tailored to the college or university's needs and the individual's preference, is being used within the university system of New Hampshire. This concept provides for year-round employment with voluntary leaves without pay. (MLW)
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-31
... remove the automatic exemption from the nonmember deposits limit that had been granted to RegFlex FCUs... created a ``well capitalized standard'' based on the automatic designation criteria used in RegFlex. An... premises. ``Premises'' means any office, branch office, suboffice, service center, parking lot, facility...
Flexible Tagged Architecture for Trustworthy Multi-core Platforms
2015-06-01
well as two kernel benchmarks for SHA - 256 and GMAC, which are popular cryptographic standards. We compared the execution time of these benchmarks...UMC UMC on Flex fabric (FPGA) 266 90,384 10.8% 21 5.8% DIFT DIFT on Flex fabric (FPGA) 256 123,471 14.8% 23 6.3% BC BC on Flex fabric (FPGA) 229...0.25X) (1X) (0.5X) (0.25X) (1X) (0.5X) (0.25X) (1X) (0.5X) (0.25X) sha 1.01 1.01 1.01 1.01 1.06 1.16 1.03 1.07 1.15 1.00 1.33 1.50 gmac 1.01 1.01 1.09
PyzoFlex: a printed piezoelectric pressure sensing foil for human machine interfaces
NASA Astrophysics Data System (ADS)
Zirkl, M.; Scheipl, G.; Stadlober, B.; Rendl, C.; Greindl, P.; Haller, M.; Hartmann, P.
2013-09-01
Ferroelectric material supports both pyro- and piezoelectric effects that can be used for sensing pressures on large, bended surfaces. We present PyzoFlex, a pressure-sensing input device that is based on a ferroelectric material (PVDF:TrFE). It is constructed by a sandwich structure of four layers that can easily be printed on any substrate. The PyzoFlex foil is sensitive to pressure- and temperature changes, bendable, energy-efficient, and it can easily be produced by a screen-printing routine. Even a hovering input-mode is feasible due to its pyroelectric effect. In this paper, we introduce this novel, fully printed input technology and discuss its benefits and limitations.
The effects of smartphone use on upper extremity muscle activity and pain threshold
Lee, Minkyung; Hong, Yunkyung; Lee, Seunghoon; Won, Jinyoung; Yang, Jinjun; Park, Sookyoung; Chang, Kyu-Tae; Hong, Yonggeun
2015-01-01
[Purpose] The purpose of this study was to determine whether muscle activity and pressure-induced pain in the upper extremities are affected by smartphone use, and to compare the effects of phone handling with one hand and with both hands. [Subjects] The study subjects were asymptomatic women 20–22 years of age. [Methods] The subjects sat in a chair with their feet on the floor and the elbow flexed, holding a smartphone positioned on the thigh. Subsequently, the subjects typed the Korean anthem for 3 min, one-handed or with both hands. Each subject repeated the task three times, with a 5-min rest period between tasks to minimize fatigue. Electromyography (EMG) was used to record the muscle activity of the upper trapezius (UT), extensor pollicis longus (EPL), and abductor pollicis (AP) during phone operation. We also used a dolorimeter to measure the pressure-induced pain threshold in the UT. [Results] We observed higher muscle activity in the UT, AP, and EPL in one-handed smartphone use than in its two-handed use. The pressure-induced pain threshold of the UT was lower after use of the smartphone, especially after one-handed use. [Conclusion] Our results show that smartphone operation with one hand caused greater UT pain and induced increased upper extremity muscle activity. PMID:26180311
NASA Astrophysics Data System (ADS)
Kuang, Yang; Daniels, Alice; Zhu, Meiling
2017-08-01
This paper presents a sandwiched piezoelectric transducer (SPT) for energy harvesting in large force environments with increased load capacity and electric power output. The SPT uses (1) flex end-caps to amplify the applied load force so as to increase its power output and (2) a sandwiched piezoelectric-substrate structure to reduce the stress concentration in the piezoelectric material so as to increase the load capacity. A coupled piezoelectric-circuit finite element model (CPC-FEM) was developed, which is able to directly predict the electric power output of the SPT connected to a load resistor. The CPC-FEM was used to study the effects of various parameters of the SPT on the performance to obtain an optimal design. These parameters included the substrate thickness, the end-cap material and thickness, the electrode length, the joint length, the end-cap internal angle and the PZT thickness. A prototype with optimised parameters was tested on a loading machine, and the experimental results were compared with simulation. A good agreement was observed between simulation and experiment. When subjected to a 1 kN 2 Hz sinusoidal force applied by the loading machine, the SPT produced an average power of 4.68 mW. The application of the SPT as a footwear energy harvester was demonstrated by fitting the SPT into a boot and performing the tests on a treadmill, and the SPT generated an average power of 2.5 mW at a walking speed of 4.8 km h-1.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-12
... Amending the NYSE Amex Options Fee Schedule To Include FLEX Option Transactions in the Strategy Execution...'') to include FLEX Option transactions in the strategy execution fee cap. The Exchange proposes to... Option transactions in the strategy execution fee cap. The Exchange proposes to implement the fee change...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-06
... Index, Equity and Currency Options) to extend a pilot program that eliminates minimum value sizes for... FLEX Options, FLEX currency options are also traded on the Exchange. These flexible index, equity, and currency options provide investors the ability to customize basic option features including size...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-07
... Index, Equity and Currency Options) to extend a pilot program that eliminates minimum value sizes for... FLEX Options, FLEX currency options are also traded on the Exchange. These flexible index, equity, and currency options provide investors the ability to customize basic option features including size...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-29
... analysis of FLEX Options trading patterns. The Exchange also provided the Commission, on a periodic basis... Effectiveness of Proposed Rule Change To Extend Pilot Programs Relating to FLEX Exercise Settlement Values and... permissible exercise settlement values and the elimination of minimum value sizes for Flexible Exchange...
Comparative Analyses of MIRT Models and Software (BMIRT and flexMIRT)
ERIC Educational Resources Information Center
Yavuz, Guler; Hambleton, Ronald K.
2017-01-01
Application of MIRT modeling procedures is dependent on the quality of parameter estimates provided by the estimation software and techniques used. This study investigated model parameter recovery of two popular MIRT packages, BMIRT and flexMIRT, under some common measurement conditions. These packages were specifically selected to investigate the…
75 FR 15328 - Airworthiness Directives; The Boeing Company Model 757 Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-29
... the flightcrew and supernumerary oxygen system installed under the oxygen mask stowage box at a flightcrew and supernumerary oxygen mask location, and replacing with a new non-conductive low-pressure flex-hose of the oxygen system if necessary. This AD results from reports of a low-pressure flex-hose of a...
ERIC Educational Resources Information Center
Christensen, Gayle S.
2007-01-01
The reauthorization of the "Elementary and Secondary Education Act" ("ESEA") as amended by the "No Child Left Behind Act of 2001" ("NCLB") relied on two notable policy instruments to improve education: accountability and flexibility. "NCLB" complements accountability with several new flexibility…
Failure analysis of braided U-shaped metal bellows flexible hoses
NASA Astrophysics Data System (ADS)
Pierce, Stephen O.
Most of the research performed extensively reviews the effects of non-reinforced metal bellows and their pressurized characteristics. However, the majority of flex hoses are manufactured with reinforcement by the means of interweaved wire braids. For this research, the outer braid reinforced metal bellows flex hoses will be examined for their failure at differing lengths. The relationship with the bellows expansion joints is such that as the length of the flex hoses increases, the pressure at which squirm occurs decreases. As such, for the testing being performed, the same approach to failure is expected. As the length of the flex hose increases, it is predicted that the hose will fail at a decreasing pressure. Since the braid is the only thing that prevents the squirm from occurring, more of the load will be displaced from the bellows and into the braid. This will ultimately cause failure of the braid to occur at a lower pressure as the length of the hoses increase due to more of the load being transmitted from the bellows and into the braid.
Functional Analysis With a Barcoder Yeast Gene Overexpression System
Douglas, Alison C.; Smith, Andrew M.; Sharifpoor, Sara; Yan, Zhun; Durbic, Tanja; Heisler, Lawrence E.; Lee, Anna Y.; Ryan, Owen; Göttert, Hendrikje; Surendra, Anu; van Dyk, Dewald; Giaever, Guri; Boone, Charles; Nislow, Corey; Andrews, Brenda J.
2012-01-01
Systematic analysis of gene overexpression phenotypes provides an insight into gene function, enzyme targets, and biological pathways. Here, we describe a novel functional genomics platform that enables a highly parallel and systematic assessment of overexpression phenotypes in pooled cultures. First, we constructed a genome-level collection of ~5100 yeast barcoder strains, each of which carries a unique barcode, enabling pooled fitness assays with a barcode microarray or sequencing readout. Second, we constructed a yeast open reading frame (ORF) galactose-induced overexpression array by generating a genome-wide set of yeast transformants, each of which carries an individual plasmid-born and sequence-verified ORF derived from the Saccharomyces cerevisiae full-length EXpression-ready (FLEX) collection. We combined these collections genetically using synthetic genetic array methodology, generating ~5100 strains, each of which is barcoded and overexpresses a specific ORF, a set we termed “barFLEX.” Additional synthetic genetic array allows the barFLEX collection to be moved into different genetic backgrounds. As a proof-of-principle, we describe the properties of the barFLEX overexpression collection and its application in synthetic dosage lethality studies under different environmental conditions. PMID:23050238
Experimental Evaluation of a New Tubular Coronary Stent (V-Flexª).
Shun; Wang; Zhou; Verbeken; Ping; Szilard; Yanming; Jianhua; De Scheerder IK
1998-11-01
The safety, efficacy, angiographic and histological effects of a new 316 L, SS seamless stainless steel tubular stent (V-Flexª, Global Therapeutics, Broomfield, Colorado) was evaluated in a porcine coronary and peripheral artery model. Implantation in the right coronary artery was successful in all 16 pigs. Eight pigs were angiographically controlled after 6 weeks and then sacrificed for morphometric analysis. All stented coronary vessels were widely patent at this moment and morphometric analysis showed only a mild fibromuscular neointimal hyperplasia resulting in a neointimal hyperplasia of 1.15 +/- 0.38 mm2. The remaining 8 pigs were controlled and sacrificed at 12 weeks. At that time, all stented vessels were patent and neointimal hyperplasia was 1.22 +/- 0.34 mm2. Comparison with the Palmaz-Schatzª coronary stent (Cordis, Miami, Florida) in a porcine peripheral artery model demonstrated significantly less neointimal hyperplasia at 6 weeks (1.11 +/- 0.73 vs. 2.40 +/- 0.36, p = 0.001) and at 12 weeks (1.53 +/- 0.42 vs. 2.47 +/- 0.63, p = 0.003) for the V-Flex stent. In conclusion, V-Flex coronary stent implantation in a porcine coronary and peripheral arteries results in a high procedural success rate without subacute thrombotic occlusions, despite no further anticoagulation nor antiplatelet therapy. Six and 12 week histopathological and morphometric evaluation demonstrated only a mild fibromuscular neointimal hyperplasia. Comparison with the Palmaz-Schatz coronary stent in a peripheral artery model showed significantly less neointimal hyperplasia in the V-Flex stent.
van der Jagt-Willems, Hanna C; de Groot, Maartje H; van Campen, Jos P C M; Lamoth, Claudine J C; Lems, Willem F
2015-03-28
Vertebral fractures, an increased thoracic kyphosis and a flexed posture are associated with falls. However, this was not confirmed in prospective studies. We performed a prospective cohort study to investigate the association between vertebral fractures, increased thoracic kyphosis and/or flexed posture with future fall incidents in older adults within the next year. Patients were recruited at a geriatric outpatient clinic. Vertebral fractures were evaluated on lateral radiographs of the spine with the semi-quantitative method of Genant; the degree of thoracic kyphosis was assessed with the Cobb angle. The occiput-to-wall distance was used to determine a flexed posture. Self-reported falls were prospectively registered by monthly phone contact for the duration of 12 months. Fifty-one older adults were included; mean age was 79 years (SD = 4.8). An increased thoracic kyphosis was independently associated with future falls (OR 2.13; 95% CI 1.10-4.51). Prevalent vertebral fractures had a trend towards significancy (OR 3.67; 95% CI 0.85-15.9). A flexed posture was not significantly associated with future falls. Older adults with an increased thoracic kyphosis are more likely to fall within the next year. We suggest clinical attention for underlying causes. Because patients with increased thoracic curvature of the spine might have underlying osteoporotic vertebral fractures, clinicians should be aware of the risk of a new fracture.
Zhao, D; Shen, Y; Peng, B; Haapasalo, M
2016-10-01
To compare the cyclic fatigue resistance of HyFlex CM, Twisted Files (TF), K3XF, Race, and K3, and evaluate the effect of autoclave sterilization on the cyclic fatigue resistance of these instruments both before and after the files were cycled. Five types of NiTi instruments with similar size 30, .06 taper were selected: HyFlex CM, TF, K3XF, Race and K3. Files were tested in a simulated canal with a curvature of 60° and a radius of 3 mm. The number of cycles to failure of each instrument was determined to evaluate cyclic fatigue resistance. Each type of instruments was randomly divided into four experimental groups: group 1 (n = 20), unsterilized instruments; group 2 (n = 20), pre-sterilized instruments subjected to 10 cycles of autoclave sterilization; group 3 (n = 20), instruments tested were sterilized at 25%, 50% and 75% of the mean cycles to failure as determined in group 1, and then cycled to failure; group 4 (n = 20), instruments cycled in the same manner as group 3 but without sterilization. The fracture surfaces of instruments were examined by scanning electron microscopy (SEM). HyFlex CM, TF and K3XF had significantly higher cyclic fatigue resistance than Race and K3 in the unsterilized group 1 (P < 0.05). Autoclave sterilization significantly increased the MCF of HyFlex CM and K3XF (P < 0.05) both before and after the files were cycled. SEM examination revealed a typical pattern of cyclic fatigue fracture in all instruments. HyFlex CM, TF and K3XF instruments composed of new thermal-treated alloy were more resistant to fatigue failure than Race and K3. Autoclaving extended the cyclic fatigue life of HyFlex CM and K3XF. © 2015 International Endodontic Journal. Published by John Wiley & Sons Ltd.
FLEX: an imaging spectrometer for measurement of vegetation fluorescence
NASA Astrophysics Data System (ADS)
Smorenburg, Kees; Visser, Huib; Court, Andrew; Stoll, Marc Ph.
2017-11-01
Detection of vegetation fluorescence gives information about plant functioning, stress and vitality. During the past decades several ground based laser fluorosensors have been developed to investigate these processes and to demonstrate the value of this technique. FLEX (= FLuorescense EXplorer) is a space mission to measure the fluorescence of vegetation on earth over large areas from space. Such a mission would greatly improve the understanding and enhance the capability to quantify e.g. the role of terrestrial vegetation in global carbon sequestration. Because the fluorescence signal, which is excited by solar irradiation is low with respect to the reflected sunlight the signal from a satellite is proposed to be measured in the solar Fraunhofer lines, where the reflection signal is much reduced. The heart of FLEX is a high resolution imaging spectrometer with 2 channels: channel 1 around the Fraunhofer lines at ‡ = 397 nm, ‡= 423 nm and/or ‡ = 434 nm and channel 2 around the Fraunhofer line at ‡ = 656 nm. The required spectral resolution will depend on the linewidth (0.02-0.3 nm). A first definition of the field of view is 8.4 degrees, leading from an 800 km satellite altitude to a swath of about 120 km. For detection a 1024x1024 pixel frame transfer CCD detector is proposed, with a pixel dimension of 13 x 13 ‡ mm2. The maximum footprint is about 500x500m2. The optical configuration contains a scan mirror for solar calibration, for pointing the FOV in swath direction and for freezing the observed ground scene up to a few seconds to increase the signal to noise performance. At this moment the concept of FLEX is elaborated in a feasibility study. Both the scientific and instrument requirements are updated and the concept is studied in detail. Besides a development plan for FLEX is made. In this paper the idea and the headlines of FLEX are described.
Gormley, Siobhan; O’Leary, Cliodhna; Rodrigues, Evangeline; Wright, Isobel; Griffiths, Kirsty; Gillard, Julia; Watson, Peter; Hammond, Emily; Werner-Seidler, Aliza; Dalgleish, Tim
2018-01-01
Introduction Major depressive disorder (MDD) is a chronic condition. Although current treatment approaches are effective in reducing acute depressive symptoms, rates of relapse are high. Chronic and inflexible retrieval of autobiographical memories, and in particular a bias towards negative and overgeneral memories, is a reliable predictor of relapse. This randomised controlled single-blind trial will determine whether a therapist-guided self-help intervention to ameliorate autobiographical memory biases using Memory Flexibility training (MemFlex) will increase the experience of depression-free days, relative to a psychoeducation control condition, in the 12 months following intervention. Methods and analysis Individuals (aged 18 and above) with a diagnosis of recurrent MDD will be recruited when remitted from a major depressive episode. Participants will be randomly allocated to complete 4 weeks of a workbook providing either MemFlex training, or psychoeducation on factors that increase risk of relapse. Assessment of diagnostic status, self-report depressive symptoms, depression-free days and cognitive risk factors for depression will be completed post-intervention, and at 6 and 12 months follow-up. The cognitive target of MemFlex will be change in memory flexibility on the Autobiographical Memory Test- Alternating Instructions. The primary clinical endpoints will be the number of depression-free days in the 12 months following workbook completion, and time to depressive relapse. Ethics and dissemination Ethics approval has been granted by the NHS National Research Ethics Committee (East of England, 11/H0305/1). Results from this study will provide a point-estimate of the effect of MemFlex on depressive relapse, which will be used to inform a fully powered trial evaluating the potential of MemFlex as an effective, low-cost and low-intensity option for reducing relapse of MDD. Trial registration number NCT02614326. PMID:29382674
2013-08-13
The Glenn Extreme Environment Chamber (GEER) simulates the extreme conditions found in space and tests many devices that will explore Venus to see if they can withstand the punishing environment and temperatures over 800 degrees F.
Kobayashi, Takuma; Yamakawa, Satoshi; Watanabe, Kota; Kimura, Kei; Suzuki, Daisuke; Otsubo, Hidenori; Teramoto, Atsushi; Fujimiya, Mineko; Fujie, Hiromichi; Yamashita, Toshihiko
2016-12-01
Numerous biomechanical studies of the lateral ankle ligaments have been reported; however, the isolated function of the calcaneofibular ligament has not been clarified. We hypothesize that the calcaneofibular ligament would stabilize the ankle joint complex under multidirectional loading, and that the in situ force in the calcaneofibular ligament would change in each flexed position. Using seven fresh frozen cadaveric lower extremities, the motions and forces of the intact ankle under multidirectional loading were recorded using a 6-degree-of-freedom robotic system. On repeating these intact ankle joint complex motions after the calcaneofibular ligament transection, the in situ force in the calcaneofibular ligament and the contribution of the calcaneofibular ligament to ankle joint complex stability were calculated. Finally, the motions of the calcaneofibular ligament-transected ankle joint complex were recorded. Under an inversion load, significant increases of inversion angle were observed in all the flexed positions following calcaneofibular ligament transection, and the calcaneofibular ligament accounted for 50%-70% of ankle joint complex stability during inversion. The in situ forces in the calcaneofibular ligament under an anterior force, inversion moment, and external rotation moment were larger in the dorsiflexed position than in the plantarflexed position. The calcaneofibular ligament plays a role in stabilizing the ankle joint complex to multidirectional loads and the role differs with load directions. The in situ force of the calcaneofibular ligament is larger at the dorsiflexed position. This ligament provides the primary restraint to the inversion ankle stability. Copyright © 2016 Elsevier Ltd. All rights reserved.
Mibu, Akira; Nishigami, Tomohiko; Tanaka, Katsuyoshi; Osumi, Michihiro; Tanabe, Akihito
2016-04-01
A 43-year-old man had deafferentation pain in his right upper extremity secondary to brachial plexus avulsion from a traffic accident 23 years previously. On our initial examination, he had severe tingling pain with numbness in the right fingers rated 10 on the numerical rating scale. The body perception of the affected third and fourth fingers was distorted in the flexed position. Although he performed traditional mirror therapy (TMT) for 4 weeks in the same methods as seen in previous studies, he could not obtain willed motor imagery and pain-alleviation effect. Therefore, we modified the task of TMT: Graded mirror therapy (GMT). GMT consisted of five stages: (1) observation of the mirror reflection of the unaffected side without imagining any movements of the affected side; (2) observation of the mirror reflection of the third and fourth fingers changing shape gradually adjusted from a flexed position to a extended position; (3) observation of the mirror reflection of passive movement; (4) motor imagery of affected fingers with observation of the mirror reflection (similar to TMT); (5) motor imagery of affected fingers without mirror. Each task was performed for 3 to 4 weeks. As a result, pain intensity during mirror therapy gradually decreased and finally disappeared. The body perception of the affected fingers also improved, and he could imagine the movement of the fingers with or without mirror. We suggested that GMT starting from the observation task without motor imagery may effectively decrease deafferentation pain compared to TMT. © 2016 World Institute of Pain.
The anatomy of Nikyo (Aikido's second teaching).
Eckert, J W; Lee, T K
1993-12-01
Nikyo is the second teaching of Aikido (ni-two, kyo-teaching, in Japanese). It is a joint-lock technique that results in extreme pain. It allows one to control an opponent by destroying his will to continue fighting. Nikyo is accomplished by flexing and adducting an opponent's wrist producing an instantaneous sharp pain that causes him to fall to his knees involuntarily to alleviate the pressure. The exact etiology of the pain elicited by this technique has been obscure to many practitioners. The usual explanations have been nerve compression, joint capsular stretch, tendon/muscle strain, or partial ligamentous disruption. Studies of a cadaver's wrist have shown that Nikyo forcibly compresses the pisiform bone against the ulna, two bones that do not normally articulate. The intense pain thereby produced results from stimulation of the periosteal nerves in these bony surfaces.
With the rise in the use of ethanol-blend gasoline in the U.S., interest is increasing in how these fuel blends affect PM and VOC emissions. EPA conducted a study characterizing emissions from two flex-fuel and one non-flex-fueled light-duty vehicles operated on a chassis dynamom...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-05
... verify the part number of the low-pressure flex-hoses of the flightcrew and supernumerary oxygen system installed under the oxygen mask stowage box at flightcrew and supernumerary oxygen mask locations, and... reports of low- pressure flex-hoses of the flightcrew oxygen system that burned through due to inadvertent...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-05
... AD requires inspecting to verify the part number of the low-pressure flex-hoses of the crew oxygen system installed under the oxygen mask stowage boxes located within the flight deck, and replacing the... of low-pressure flex-hoses of the crew oxygen system that burned through due to inadvertent...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-22
... oxygen system installed under the oxygen mask stowage boxes located within the flight deck, and replacing... from reports of low-pressure flex-hoses of the crew oxygen system that burned through due to... prevent inadvertent electrical current, which can cause the low-pressure flex-hoses of the crew oxygen...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-05
... overlap. In addition, unrelated FLEX Orders may not be submitted to the electronic book for the duration... available an electronic book). Public customers and non-TPH broker-dealers RFR responses and FLEX Orders... AIM Auction price locks a public customer or non-TPH broker-dealer order in the electronic book on the...
Alternative Fuels Data Center: Alabama Transportation Data for Alternative
Renewable Energy Laboratory Case Studies Video thumbnail for Alabama Prisons Adopt Propane, Establish Fuel , 2016 Video thumbnail for City of Hoover Fleet Boasts 200-Plus Flex Fuel Vehicles City of Hoover Fleet Boasts 200-Plus Flex Fuel Vehicles May 24, 2013 Video thumbnail for Biodiesel Fuels Education in Alabama
Flex-gear electrical power transmission
NASA Technical Reports Server (NTRS)
Vranish, John; Peritt, Jonathan
1993-01-01
This study was conducted to develop an alternative way of transferring electricity across a continuously rotating joint, with little wear and the potential for low electrical noise. The problems with wires, slip rings, electromagnetic couplings, and recently invented roll-rings are discussed. Flex-gears, an improvement of roll-rings, are described. An entire class of flexgear devices is developed. Finally, the preferred flex-gear device is optimized for maximum electrical contact and analyzed for average mechanical power loss and maximum stress. For a device diameter of six inches, the preferred device is predicted to have a total electrical contact area of 0.066 square inches. In the preferred device, a small amount of internal sliding produces a 0.003 inch-pound torque that resists the motion of the device.
Semi-flexible gas-insulated transmission line using sandwiched discs for intermittent flexing joints
Kommineni, P.R.
1983-02-15
A gas-insulated transmission line includes an outer sheath, an inner conductor, an insulating gas electrically insulating the inner conductor from the outer sheath, and insulating supports insulatably supporting the inner conductor within the outer sheath. The inner conductor is provided with flexibility by the use of main conductor sections which are joined together through a conductor hub section and flexible flexing elements. Stress shields are provided to control the electric field at the locations of the conductor hub sections where the insulating supports are contacting the inner conductor. The flexing elements are formed by sandwiching together, by fusing, a pair of thin hollow discs which are fixedly secured to both the main conductor sections and the conductor hub section. 4 figs.
FleXConf: A Flexible Conference Assistant Using Context-Aware Notification Services
NASA Astrophysics Data System (ADS)
Armenatzoglou, Nikos; Marketakis, Yannis; Kriara, Lito; Apostolopoulos, Elias; Papavasiliou, Vicky; Kampas, Dimitris; Kapravelos, Alexandros; Kartsonakis, Eythimis; Linardakis, Giorgos; Nikitaki, Sofia; Bikakis, Antonis; Antoniou, Grigoris
Integrating context-aware notification services to ubiquitous computing systems aims at the provision of the right information to the right users, at the right time, in the right place, and on the right device, and constitutes a significant step towards the realization of the Ambient Intelligence vision. In this paper, we present FlexConf, a semantics-based system that supports location-based, personalized notification services for the assistance of conference attendees. Its special features include an ontology-based representation model, rule-based context-aware reasoning, and a novel positioning system for indoor environments.
[Quantitative evaluation of acrylic and silicone intraocular lenses with a sharp optic edge design].
Rabsilber, T M; Reuland, A J; Entz, B B; Holzer, M P; Limberger, I J; Auffarth, G U
2006-01-01
At the Department of Ophthalmology, Heidelberg, Germany, posterior capsule opacification (PCO) of a silicone and an acrylic intraocular lens (IOL) with a sharp optic edge design was evaluated. In a prospective study either the AMO ClariFlex silicone IOL or the Sensar AR40e hydrophobic acrylic IOL were implanted in 47 patients following uneventful phacoemulsification. Mean patient age was 76.2+/-7.8 (ClariFlex) and 73.4+/-12.9 years (AR40e), respectively. The mean follow-up time was 19.7+/-5.34 in the ClariFlex and 21.9+/-1.89 months in the AR40e group. PCO development was evaluated postoperatively using the EPCO 2000 analysis software (scale 0-4). Areas of interest were the total IOL optic, the central 3-mm zone as well as the capsulorhexis. In both groups, all patients achieved a BCVA of 20/32 (AR40e) and 20/25 (ClariFlex), respectively. There was a very low incidence of PCO development with a mean EPCO score of 0.07+/-0.2 (ClariFlex and 0.15+/-0.2 (AR40e). Within the 3-mm zone and the capsulorhexis, there was a tendency for even lower EPCO scores in both groups. We calculated a statistically significant difference for the two lens materials for all investigated IOL areas (Wilcoxon's test, p<0.05). Both IOLs with a sharp edge design showed good functional results, a stable position in the capsular bag as well as a low incidence of PCO development. However, the silicone IOL showed statistically significantly lower PCO scores.
Yılmaz, K; Uslu, G; Gündoğar, M; Özyürek, T; Grande, N M; Plotino, G
2018-01-31
To compare the cyclic fatigue resistance of the One G, ProGlider, HyFlex EDM and R-Pilot glide path NiTi files at body temperature. Twenty One G (size 14, .03 taper), 20 ProGlider (size 16, .02 taper), 20 HyFlex EDM (size 10, .05 taper) and 20 R-Pilot (size 12.5, .04 taper) instruments were operated in rotation at 300 rpm (One G, ProGlider and HyFlex) or in reciprocation (R-Pilot) at 35 °C in artificial canals that were manufactured by reproducing the size and taper of the instrument until fracture occurred. The time to fracture was recorded in seconds using a digital chronometer, and the length of the fractured fragments was registered. Mean data were analysed statistically using the Kruskal-Wallis test and post hoc Tukey tests via SPSS 21.0 software. The statistical significance level was set at 5%. The cyclic fatigue resistance of the R-Pilot files was significantly greater than the other instruments, and the One G was significantly lower (P < 0.05). There was no difference between the HyFlex EDM and the ProGlider (P > 0.05). No significant difference (P > 0.05) was evident in the mean length of the fractured fragments of the various instruments. The cyclic fatigue resistance of the R-Pilot reciprocating glide path file was significantly greater than that of the rotary HyFlex EDM, ProGlider and One G glide path files. © 2018 International Endodontic Journal. Published by John Wiley & Sons Ltd.
Yadav, Nirbhay N; Jones, Craig K; Hua, Jun; Xu, Jiadi; van Zijl, Peter C M
2013-04-01
To image endogenous exchangeable proton signals in the human brain using a recently reported method called frequency labeled exchange transfer (FLEX) MRI. As opposed to labeling exchangeable protons using saturation (i.e., chemical exchange saturation transfer, or CEST), FLEX labels exchangeable protons with their chemical shift evolution. The use of short high-power frequency pulses allows more efficient labeling of rapidly exchanging protons, while time domain acquisition allows removal of contamination from semi-solid magnetization transfer effects. FLEX-based exchangeable proton signals were detected in human brain over the 1-5 ppm frequency range from water. Conventional magnetization transfer contrast and the bulk water signal did not interfere in the FLEX spectrum. The information content of these signals differed from in vivo CEST data in that the average exchange rate of these signals was 350-400 s(-1) , much faster than the amide signal usually detected using direct saturation (∼30 s(-1) ). Similarly, fast exchanging protons could be detected in egg white in the same frequency range where amide and amine protons of mobile proteins and peptides are known to resonate. FLEX MRI in the human brain preferentially detects more rapidly exchanging amide/amine protons compared to traditional CEST experiments, thereby changing the information content of the exchangeable proton spectrum. This has the potential to open up different types of endogenous applications as well as more easy detection of rapidly exchanging protons in diaCEST agents or fast exchanging units such as water molecules in paracest agents without interference of conventional magnetization transfer contrast. Copyright © 2013 Wiley Periodicals, Inc.
Leahy, Fiona; Ridout, Nathan; Holland, Carol
2018-05-07
Autobiographical memory specificity (AMS) reduces with increasing age and is associated with depression, social problem-solving and functional limitations. However, ability to switch between general and specific, as well as between positive and negative retrieval, may be more important for the strategic use of autobiographical information in everyday life. Ability to switch between retrieval modes is likely to rely on aspects of executive function. We propose that age-related deficits in cognitive flexibility impair AMS, but the "positivity effect" protects positively valenced memories from impaired specificity. A training programme to improve the ability to flexibly retrieve different types of memories in depressed adults (MemFlex) was examined in non-depressed older adults to determine effects on AMS, valence and the executive functions underlying cognitive flexibility. Thirty-nine participants aged 70+ (MemFlex, n = 20; control, n = 19) took part. AMS and the inhibition aspect of executive function improved in both groups, suggesting these abilities are amenable to change, although not differentially affected by this type of training. Lower baseline inhibition scores correlated with increased negative, but not positive AMS, suggesting that positive AMS is an automatic process in older adults. Changes in AMS correlated with changes in social problem-solving, emphasising the usefulness of AMs in a social environment.
Unexpected Control Structure Interaction on International Space Station
NASA Technical Reports Server (NTRS)
Gomez, Susan F.; Platonov, Valery; Medina, Elizabeth A.; Borisenko, Alexander; Bogachev, Alexey
2017-01-01
On June 23, 2011, the International Space Station (ISS) was performing a routine 180 degree yaw maneuver in support of a Russian vehicle docking when the on board Russian Segment (RS) software unexpectedly declared two attitude thrusters failed and switched thruster configurations in response to unanticipated ISS dynamic motion. Flight data analysis after the maneuver indicated that higher than predicted structural loads had been induced at various locations on the United States (U.S.) segment of the ISS. Further analysis revealed that the attitude control system was firing thrusters in response to both structural flex and rigid body rates, which resonated the structure and caused high loads and fatigue cycles. It was later determined that the thruster themselves were healthy. The RS software logic, which was intended to react to thruster failures, had instead been heavily influenced by interaction between the control system and structural flex. This paper will discuss the technical aspects of the control structure interaction problem that led to the RS control system firing thrusters in response to structural flex, the factors that led to insufficient preflight analysis of the thruster firings, and the ramifications the event had on the ISS. An immediate consequence included limiting which thrusters could be used for attitude control. This complicated the planning of on-orbit thruster events and necessitated the use of suboptimal thruster configurations that increased propellant usage and caused thruster lifetime usage concerns. In addition to the technical aspects of the problem, the team dynamics and communication shortcomings that led to such an event happening in an environment where extensive analysis is performed in support of human space flight will also be examined. Finally, the technical solution will be presented, which required a multidisciplinary effort between the U.S. and Russian control system engineers and loads and dynamics structural engineers to develop and implement an extensive modification in the RS software logic for ISS attitude control thruster firings.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-25
... prices. See Exchange Rule 1079. FLEX Options are a trademark of the Chicago Board Options Exchange. While... transactions executed pursuant to Exchange Rule 1079 (``FLEX equity options''). The Exchange believes that the... options transactions executed pursuant to Exchange Rule 1079. \\11\\ 15 U.S.C. 78f(b). \\12\\ 15 U.S.C. 78f(b...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-01
... prices. See Exchange Rule 1079. FLEX Options are a trademark of the Chicago Board Options Exchange. While... pursuant to Exchange Rule 1079 (``FLEX equity options''). The Exchange believes that the proposed fee... options transactions executed pursuant to Exchange Rule 1079. \\11\\ 15 U.S.C. 78f(b). \\12\\ 15 U.S.C. 78f(b...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-04
... and open outcry RFQs, or information on resting orders in the FLEX electronic book. Normally, an AIM... be submitted to the electronic book for the duration of an AIM Auction. See proposed Rule 24B.5A(b... book).\\13\\ Second, public customers and non-Trading Permit Holder broker-dealers RFR responses and FLEX...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-21
... currency, (2) type, size and crossing intention (3) in the case of FLEX index options and FLEX equity... available. If the Requesting Member has not indicated an intention to cross or act as principal with respect... reject the BBO(s). If the Requesting Member has indicated an intention to cross or act as principal with...
Evaluation of a New 1H/31P Dual-Tuned Birdcage Coil for 31P Spectroscopy
Potter, WM; Wang, L; McCully, KK; Zhao, Q
2013-01-01
We introduce a new dual-tuned Hydrogen/Phosphorus (1H/31P) birdcage coil, referred to as split birdcage coil, and evaluate its performance using both simulations and magnetic resonance (MR) experiments on a 3 T MR scanner. The proposed coil simplifies the practical matters of tuning and matching, which makes the coil easily reproducible. Simulations were run with the Finite Difference in Time Domain (FDTD) method to evaluate the sensitivity and homogeneity of the magnetic field generated by the proposed 1H coils. Following simulations, MR experiments were conducted using both a phantom and human thigh to compare the proposed design with a currently available commercial dual-tuned flexible surface coil, referred to as flex surface coil, for signal to noise ratio (SNR) as well as homogeneity for the 31P coil. At regions deep within the human thigh, the split birdcage coil was able to acquire spectroscopic signal with a higher average SNR than the flex surface coil. For all regions except those close to the flex surface coil, the split birdcage coil matched or exceeded the performance of the flex surface coil. PMID:24039555
Mizu-Uchi, Hideki; Colwell, Clifford W; Fukagawa, Shingo; Matsuda, Shuichi; Iwamoto, Yukihide; D'Lima, Darryl D
2012-10-01
We constructed patient-specific models from computed tomography data after total knee arthroplasty to predict knee flexion based on implant-bone impingement. The maximum flexion before impingement between the femur and the tibial insert was computed using a musculoskeletal modeling program (KneeSIM; LifeModeler, Inc, San Clemente, California) during a weight-bearing deep knee bend. Postoperative flexion was measured in a clinical cohort of 21 knees (low-flex group: 6 knees with <100° of flexion and high-flex group: 15 size-matched knees with >125° of flexion at 2 years). Average predicted flexion angles were within 2° of clinical measurements for the high-flex group. In the low-flex group, 4 cases had impingement involving the bone cut at the posterior condyle, and the average predicted knee flexion was 102° compared with 93° measured clinically. These results indicate that the level of the distal femoral resection should be carefully planned and that exposed bone proximal to the tips of the posterior condyles of the femoral component should be removed if there is risk of impingement. Copyright © 2012 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kaplan, D.; Powell, B.; Barber, K.
The SRNL Radiological Field Lysimeter Experiment (RadFLEx) is a one-of-a-kind test bed facility designed to study radionuclide geochemical processes in the Savannah River Site (SRS) vadose zone at a larger spatial scale (from grams to tens of kilograms of sediment) and temporal scale (from months to decade) than is readily afforded through laboratory studies. RadFLEx is a decade-long project that was initiated on July 5, 2012 and is funded by six different sources. The objective of this status report is as follows: 1) to report findings to date that have an impact on SRS performance assessment (PA) calculations, and 2)more » to provide performance metrics of the RadFLEx program. The PA results are focused on measurements of transport parameters, such as distribution coefficients (Kd values), solubility, and unsaturated flow values. As this is an interim report, additional information from subsequent research may influence our interpretation of current results. Research related to basic understanding of radionuclide geochemistry in these vadose zone soils and other source terms are not described here but are referenced for the interested reader.« less
Local self-energies for V and Pd emergent from a nonlocal LDA+FLEX implementation
NASA Astrophysics Data System (ADS)
Savrasov, Sergey Y.; Resta, Giacomo; Wan, Xiangang
2018-04-01
In the spirit of recently developed LDA+U and LDA+DMFT methods, we implement a combination of density functional theory in its local density approximation (LDA) with a k - and ω -dependent self-energy found from diagrammatic fluctuational exchange (FLEX) approximation. The active Hilbert space here is described by the correlated subset of electrons which allows one to tremendously reduce the sizes of the matrices needed to represent charge and spin susceptibilities. The method is perturbative in nature but accounts for both bubble and ladder diagrams and accumulates the physics of momentum-resolved spin fluctuations missing in such popular approach as GW. As an application, we study correlation effects on band structures in V and Pd. The d -electron self-energies emergent from this calculation are found to be remarkably k independent. However, when we compare our calculated electronic mass enhancements against LDA+DMFT, we find that for the longstanding problem of spin fluctuations in Pd, LDA+FLEX delivers a better agreement with experiment, although this conclusion depends on a particular value of the Hubbard U used in the simulation. We also discuss outcomes of a recently proposed combination of k -dependent FLEX with dynamical mean-field theory (DMFT).
Glenn Extreme Environment Rig (GEER)
2017-01-17
NASA Glenn research engineers prepare our extreme environments chamber (GEER) for a test. GEER, which simulates the extreme conditions found in space, tests many devices that will explore Venus to see if they can withstand the punishing environment and temperatures over 800˚F.
The effect of reinforcement on the tear properties of flexible circuits
NASA Astrophysics Data System (ADS)
Acton, A. E.
The tear properties of Kapton flexible circuitry are very poor. To better understand the properties of flex circuits and how to reinforce them, four different reinforcing materials were applied to a typical flex circuit and the tear properties were measured. Teflon film, nylon fabric, glass fabric and Kevlar fabric were all laminated to a flex circuit with Pyralux (a Dupont tradename) adhesive. The fabrics were laminated in both a 0/90 and a + or - 45 configuration. Five tests wereperformed, Graves, crescent, trousers, tensile and single edge notch (SEN). Of the four materials used for reinforcement, Kevlar clearly showed the greatest overall improvement in tear properties. However, Kevlar also provided the greatest processing difficulties. All of the reinforced circuits had an increase in thickness which resulted in an unacceptable loss of flexibility.
CABS-flex: server for fast simulation of protein structure fluctuations
Jamroz, Michal; Kolinski, Andrzej; Kmiecik, Sebastian
2013-01-01
The CABS-flex server (http://biocomp.chem.uw.edu.pl/CABSflex) implements CABS-model–based protocol for the fast simulations of near-native dynamics of globular proteins. In this application, the CABS model was shown to be a computationally efficient alternative to all-atom molecular dynamics—a classical simulation approach. The simulation method has been validated on a large set of molecular dynamics simulation data. Using a single input (user-provided file in PDB format), the CABS-flex server outputs an ensemble of protein models (in all-atom PDB format) reflecting the flexibility of the input structure, together with the accompanying analysis (residue mean-square-fluctuation profile and others). The ensemble of predicted models can be used in structure-based studies of protein functions and interactions. PMID:23658222
CABS-flex: Server for fast simulation of protein structure fluctuations.
Jamroz, Michal; Kolinski, Andrzej; Kmiecik, Sebastian
2013-07-01
The CABS-flex server (http://biocomp.chem.uw.edu.pl/CABSflex) implements CABS-model-based protocol for the fast simulations of near-native dynamics of globular proteins. In this application, the CABS model was shown to be a computationally efficient alternative to all-atom molecular dynamics--a classical simulation approach. The simulation method has been validated on a large set of molecular dynamics simulation data. Using a single input (user-provided file in PDB format), the CABS-flex server outputs an ensemble of protein models (in all-atom PDB format) reflecting the flexibility of the input structure, together with the accompanying analysis (residue mean-square-fluctuation profile and others). The ensemble of predicted models can be used in structure-based studies of protein functions and interactions.
Plant volatiles in extreme terrestrial and marine environments.
Rinnan, Riikka; Steinke, Michael; McGenity, Terry; Loreto, Francesco
2014-08-01
This review summarizes the current understanding on plant and algal volatile organic compound (VOC) production and emission in extreme environments, where temperature, water availability, salinity or other environmental factors pose stress on vegetation. Here, the extreme environments include terrestrial systems, such as arctic tundra, deserts, CO₂ springs and wetlands, and marine systems such as sea ice, tidal rock pools and hypersaline environments, with mangroves and salt marshes at the land-sea interface. The emission potentials at fixed temperature and light level or actual emission rates for phototrophs in extreme environments are frequently higher than for organisms from less stressful environments. For example, plants from the arctic tundra appear to have higher emission potentials for isoprenoids than temperate species, and hypersaline marine habitats contribute to global dimethyl sulphide (DMS) emissions in significant amounts. DMS emissions are more widespread than previously considered, for example, in salt marshes and some desert plants. The reason for widespread VOC, especially isoprenoid, emissions from different extreme environments deserves further attention, as these compounds may have important roles in stress resistance and adaptation to extremes. Climate warming is likely to significantly increase VOC emissions from extreme environments both by direct effects on VOC production and volatility, and indirectly by altering the composition of the vegetation. © 2014 John Wiley & Sons Ltd.
Balloon-borne 3-meter telescope for far-infrared and submillimeter astronomy
NASA Technical Reports Server (NTRS)
Fazio, G. G.
1986-01-01
The gimbal design was studied and revised to eliminate the alignment and limited rotation problems inherent in the flex-pivot design. A new design using ball-bearings to replace the flex-pivot was defined and its performance analyzed. An error analysis for the entire gondola pointing system was also prepared. Mirror development and the test program using mirror test blanks from Dornier were continued.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-20
... Proposed Rule Change 1. Purpose The Exchange proposes to waive the CMI and FIX Login ID fees through September 30, 2012 for CMI and FIX Login IDs used to access the Exchange's FLEX Hybrid Trading System (the... each CMI or FIX Login ID that a TPH uses to access CBOEdirect (and $1000 per month for each CMI or FLEX...
ERIC Educational Resources Information Center
Svehlik, Martin; Steinwender, Gerhard; Kraus, Tanja; Saraph, Vinay; Lehmann, Thomas; Linhart, Wolfgang E.; Zwick, Ernst B.
2011-01-01
Aim: Information on the timing and long-term outcome of single-event multilevel surgery in children with bilateral spastic cerebral palsy (CP) walking with flexed knee gait is limited. Based on our clinical experience, we hypothesized that older children with bilateral spastic CP would benefit more from single-event multilevel surgery than younger…
Balloon-borne three-meter telescope for far-infrared and submillimeter astronomy
NASA Technical Reports Server (NTRS)
Fazio, Giovanni G.
1986-01-01
The study and revision of the gimbal design of the Three-Meter Balloon Borne Telescope (TMBBT) is discussed. Efforts were made to eliminate the alignment and limited rotation problems inherent in the flex-pivot design. A new design using ball bearings to replace the flex-pivots was designed and its performance analyzed. An error analysis for the entire gondola pointing system was also prepared.
Wiegratz, Inka; Elliesen, Jörg; Paoletti, Anna Maria; Walzer, Anja; Kirsch, Bodo
2015-01-01
Objective To evaluate the effect of a digital dispenser’s acoustic alarm function on adherence to ethinylestradiol (EE) 20 μg/drospirenone 3 mg in a flexible extended regimen (EE/drospirenoneFlex) among women in five European countries (France, Germany, Italy, Spain, UK) seeking oral contraception. Study design Randomized, parallel-group open-label study. Methods Women aged 18–35 years received EE/drospirenoneFlex administered in a regimen with cycle lengths of their choice with the aid of a digital pill dispenser over 1 year. In group A (N=250), the dispenser’s acoustic alarm was activated (ie, acoustic alarm + visual reminder). In group B (N=249), the acoustic alarm was deactivated (ie, visual reminder only). In addition, the women recorded pill intake daily in diary cards. The primary efficacy variable was the mean delay of daily pill release after the dispenser reminded the woman to take a pill (reference time). Secondary efficacy variables included number of missed pills, contraceptive efficacy, bleeding pattern, tolerability, and user satisfaction. Results Dispenser data showed a mean (standard deviation [SD]) daily delay in pill release of 88 (126) minutes in group A vs 178 (140) minutes in group B (P<0.0001). Median (lower quartile, Q1; upper quartile, Q3) number of missed pills was 0 (0; 1) in group A vs 4 (1; 9) in group B (P<0.0001). Diary card results revealed similar trends; however, underreporting of missed pills was evident in both groups. No pregnancies were reported during 424 women-years of exposure. Across the two groups, the mean (SD) EE/drospirenoneFlex cycle length was 51.0 (31.8) days with strong regional differences, and the mean (SD) number of bleeding/spotting days was 50.4 (33.0) days. EE/drospirenoneFlex was well tolerated, and 80% of women were satisfied with treatment. Conclusion The dispenser’s activated acoustic alarm improved adherence with daily tablet intake of EE/drospirenoneFlex, reducing missed pills. EE/drospirenoneFlex provided effective contraception and a good tolerability profile. PMID:25609999
Ma, Jing; Cao, Nan-Jue; Xia, Li-Kun
2016-01-01
To identify possible differences of efficacy, safety, predictability, higher-order aberrations and corneal biomechnical parameters after small-incision lenticule extraction (SMILE) and femtosecond lenticule extraction (FLEx). A systematic literature retrieval was conducted in Medline, Embase and the Cochrane Library, up to October, 2015. The included studies were subject to a Meta-analysis. Comparison between SMILE and FLEx was measured as pooled odds ratio (OR) or weighted mean differences (WMD). Of 95% confidence intervals (CI) were used to analyze data. A total of seven studies were included. Firstly, there were no differences in uncorrected distance visual acuity (UDVA) 20/20 or better (OR, 1.37; 95% CI, 0.69 to 2.69; P=0.37) and logMAR UDVA (WMD, -0.02; 95% CI, -0.05 to 0.01; P=0.17) after SMILE versus FLEx. We found no differences in corrected distance visual acuity (CDVA) unchanged (OR, 0.98; 95% CI, 0.46 to 2.11; P=0.97) and logMAR CDVA (WMD, -0.00; 95% CI, -0.01 to 0.01; P=0.90) either. Secondly, we found no differences in refraction within ±1.00 D (OR, 0.98; 95% CI, 0.13 to 7.28; P=0.99) and ±0.50 D (OR, 1.62; 95% CI, 0.62 to 4.28; P=0.33) of target postoperatively. Thirdly, for higher-order aberrations, we found no differences in the total higher-order aberrations (WMD, -0.04; 95% CI, -0.09 to 0.01; P=0.14), coma (WMD, -0.04; 95% CI, -0.09 to 0.01; P=0.11), spherical (WMD, 0.01; 95% CI, -0.02 to 0.03; P=0.60) and trefoil (WMD, -0.00; 95% CI, -0.04 to 0.03; P=0.76). Furthermore, for corneal biomechanical parameters, we also found no differences (WMD, 0.08; 95% CI, -0.17 to 0.33; P=0.54) after SMILE versus FLEx. There are no statistically differences in efficacy, safety, predictability, higher-order aberrations and corneal biomechnical parameters postoperative between SMILE and FLEx.
Hitchcock, Caitlin; Hammond, Emily; Rees, Catrin; Panesar, Inderpal; Watson, Peter; Werner-Seidler, Aliza; Dalgleish, Tim
2015-11-03
Major depressive disorder (MDD) is associated with chronic biases in the allocation of attention and recollection of personal memories. Impaired flexibility in attention and autobiographical memory retrieval is seen to both maintain current symptoms and predict future depression. Development of innovative interventions to reduce maladaptive cognitive patterns and improve cognitive flexibility in the domain of memory may therefore advance current treatment approaches for depression. Memory specificity training and cognitive bias modification techniques have both shown some promise in improving cognitive flexibility. Here we outline plans for a trial of an innovative memory flexibility training programme, MemFlex, which advances current training techniques with the aim of improving flexibility of autobiographical memory retrieval. This trial seeks to estimate the efficacy of MemFlex, provide data on feasibility, and begin to explore mechanisms of change. We plan a single-blind, randomised, controlled, patient-level trial in which 50 individuals with MDD will complete either psychoeducation (n = 25) or MemFlex (n = 25). After completing pre-treatment measures and an orientation session, participants complete eight workbook-based sessions at home. Participants will then be assessed at post-treatment and at 3 month follow-up. The co-primary outcomes are depressive symptoms and diagnostic status at 3 month follow-up. The secondary outcomes are memory flexibility at post-treatment and number of depression free days at 3 month follow-up. Other process outcomes and mediators of any treatment effects will also be explored. This trial will establish the efficacy of MemFlex in improving memory flexibility, and reducing depressive symptoms. Any effects on process measures related to relapse may also indicate whether MemFlex may be helpful in reducing vulnerability to future depressive episodes. The low-intensity and workbook-based format of the programme may improve access to psychological therapies, and, if encouraging, the results of this study will provide a platform for later-phase trials. NCT02371291 (ClinicalTrials.gov), registered 9 February 2015.
Wearable Activity Tracker Use Among Australian Adolescents: Usability and Acceptability Study
Timperio, Anna; Brown, Helen; Ball, Kylie; Macfarlane, Susie; Lai, Samuel K; Richards, Kara; Mackintosh, Kelly A; McNarry, Melitta A; Foster, Megan; Salmon, Jo
2018-01-01
Background Wearable activity trackers have the potential to be integrated into physical activity interventions, yet little is known about how adolescents use these devices or perceive their acceptability. Objective The aim of this study was to examine the usability and acceptability of a wearable activity tracker among adolescents. A secondary aim was to determine adolescents’ awareness and use of the different functions and features in the wearable activity tracker and accompanying app. Methods Sixty adolescents (aged 13-14 years) in year 8 from 3 secondary schools in Melbourne, Australia, were provided with a wrist-worn Fitbit Flex and accompanying app, and were asked to use it for 6 weeks. Demographic data (age, sex) were collected via a Web-based survey completed during week 1 of the study. At the conclusion of the 6-week period, all adolescents participated in focus groups that explored their perceptions of the usability and acceptability of the Fitbit Flex, accompanying app, and Web-based Fitbit profile. Qualitative data were analyzed using pen profiles, which were constructed from verbatim transcripts. Results Adolescents typically found the Fitbit Flex easy to use for activity tracking, though greater difficulties were reported for monitoring sleep. The Fitbit Flex was perceived to be useful for tracking daily activities, and adolescents used a range of features and functions available through the device and the app. Barriers to use included the comfort and design of the Fitbit Flex, a lack of specific feedback about activity levels, and the inability to wear the wearable activity tracker for water-based sports. Conclusions Adolescents reported that the Fitbit Flex was easy to use and that it was a useful tool for tracking daily activities. A number of functions and features were used, including the device’s visual display to track and self-monitor activity, goal-setting in the accompanying app, and undertaking challenges against friends. However, several barriers to use were identified, which may impact on sustained use over time. Overall, wearable activity trackers have the potential to be integrated into physical activity interventions targeted at adolescents, but both the functionality and wearability of the monitor should be considered. PMID:29643054
Sushames, Ashleigh; Edwards, Andrew; Thompson, Fintan; McDermott, Robyn; Gebel, Klaus
2016-01-01
Objectives To examine the validity and reliability of the Fitbit Flex against direct observation for measuring steps in the laboratory and against the Actigraph for step counts in free-living conditions and for moderate-to-vigorous physical activity (MVPA) and activity energy expenditure (AEE) overall. Methods Twenty-five adults (12 females, 13 males) wore a Fitbit Flex and an Actigraph GT3X+ during a laboratory based protocol (including walking, incline walking, running and stepping) and free-living conditions during a single day period to examine measurement of steps, AEE and MVPA. Twenty-four of the participants attended a second session using the same protocol. Results Intraclass correlations (ICC) for test-retest reliability of the Fitbit Flex were strong for walking (ICC = 0.57), moderate for stair stepping (ICC = 0.34), and weak for incline walking (ICC = 0.22) and jogging (ICC = 0.26). The Fitbit significantly undercounted walking steps in the laboratory (absolute proportional difference: 21.2%, 95%CI 13.0–29.4%), but it was more accurate, despite slightly over counting, for both jogging (6.4%, 95%CI 3.7–9.0%) and stair stepping (15.5%, 95%CI 10.1–20.9%). The Fitbit had higher coefficients of variation (Cv) for step counts compared to direct observation and the Actigraph. In free-living conditions, the average MVPA minutes were lower in the Fitbit (35.4 minutes) compared to the Actigraph (54.6 minutes), but AEE was greater from the Fitbit (808.1 calories) versus the Actigraph (538.9 calories). The coefficients of variation were similar for AEE for the Actigraph (Cv = 36.0) and Fitbit (Cv = 35.0), but lower in the Actigraph (Cv = 25.5) for MVPA against the Fitbit (Cv = 32.7). Conclusion The Fitbit Flex has moderate validity for measuring physical activity relative to direct observation and the Actigraph. Test-rest reliability of the Fitbit was dependant on activity type and had greater variation between sessions compared to the Actigraph. Physical activity surveillance studies using the Fitbit Flex should consider the potential effect of measurement reactivity and undercounting of steps. PMID:27589592
Variable stiffness torsion springs
NASA Astrophysics Data System (ADS)
Alhorn, Dean C.; Polites, Michael E.
1994-05-01
In a torsion spring the spring action is a result of the relationships between the torque applied in twisting the spring, the angle through which the torsion spring twists, and the modulus of elasticity of the spring material in shear. Torsion springs employed industrially have been strips, rods, or bars, generally termed shafts, capabable of being flexed by twisting their axes. They rely on the variations in shearing forces to furnish an internal restoring torque. In the torsion springs herein the restoring torque is external and therefore independent of the shearing modulus of elasticity of the torsion spring shaft. Also provided herein is a variable stiffness torsion spring. This torsion spring can be so adjusted as to have a given spring constant. Such variable stiffness torsion springs are extremely useful in gimballed payloads such as sensors, telescopes, and electronic devices on such platforms as a space shuttle or a space station.
Variable stiffness torsion springs
NASA Technical Reports Server (NTRS)
Alhorn, Dean C. (Inventor); Polites, Michael E. (Inventor)
1995-01-01
In a torsion spring the spring action is a result of the relationships between the torque applied in twisting the spring, the angle through which the torsion spring twists, and the modulus of elasticity of the spring material in shear. Torsion springs employed industrially have been strips, rods, or bars, generally termed shafts, capabable of being flexed by twisting their axes. They rely on the variations in shearing forces to furnish an internal restoring torque. In the torsion springs herein the restoring torque is external and therefore independent of the shearing modulus of elasticity of the torsion spring shaft. Also provided herein is a variable stiffness torsion spring. This torsion spring can be so adjusted as to have a given spring constant. Such variable stiffness torsion springs are extremely useful in gimballed payloads such as sensors, telescopes, and electronic devices on such platforms as a space shuttle or a space station.
Variable stiffness torsion springs
NASA Astrophysics Data System (ADS)
Alhorn, Dean C.; Polites, Michael E.
1995-08-01
In a torsion spring the spring action is a result of the relationships between the torque applied in twisting the spring, the angle through which the torsion spring twists, and the modulus of elasticity of the spring material in shear. Torsion springs employed industrially have been strips, rods, or bars, generally termed shafts, capabable of being flexed by twisting their axes. They rely on the variations in shearing forces to furnish an internal restoring torque. In the torsion springs herein the restoring torque is external and therefore independent of the shearing modulus of elasticity of the torsion spring shaft. Also provided herein is a variable stiffness torsion spring. This torsion spring can be so adjusted as to have a given spring constant. Such variable stiffness torsion springs are extremely useful in gimballed payloads such as sensors, telescopes, and electronic devices on such platforms as a space shuttle or a space station.
Variable stiffness torsion springs
NASA Technical Reports Server (NTRS)
Alhorn, Dean C. (Inventor); Polites, Michael E. (Inventor)
1994-01-01
In a torsion spring the spring action is a result of the relationships between the torque applied in twisting the spring, the angle through which the torsion spring twists, and the modulus of elasticity of the spring material in shear. Torsion springs employed industrially have been strips, rods, or bars, generally termed shafts, capabable of being flexed by twisting their axes. They rely on the variations in shearing forces to furnish an internal restoring torque. In the torsion springs herein the restoring torque is external and therefore independent of the shearing modulus of elasticity of the torsion spring shaft. Also provided herein is a variable stiffness torsion spring. This torsion spring can be so adjusted as to have a given spring constant. Such variable stiffness torsion springs are extremely useful in gimballed payloads such as sensors, telescopes, and electronic devices on such platforms as a space shuttle or a space station.
Microbial diversity of extreme habitats in human homes.
Savage, Amy M; Hills, Justin; Driscoll, Katherine; Fergus, Daniel J; Grunden, Amy M; Dunn, Robert R
2016-01-01
High-throughput sequencing techniques have opened up the world of microbial diversity to scientists, and a flurry of studies in the most remote and extreme habitats on earth have begun to elucidate the key roles of microbes in ecosystems with extreme conditions. These same environmental extremes can also be found closer to humans, even in our homes. Here, we used high-throughput sequencing techniques to assess bacterial and archaeal diversity in the extreme environments inside human homes (e.g., dishwashers, hot water heaters, washing machine bleach reservoirs, etc.). We focused on habitats in the home with extreme temperature, pH, and chemical environmental conditions. We found a lower diversity of microbes in these extreme home environments compared to less extreme habitats in the home. However, we were nonetheless able to detect sequences from a relatively diverse array of bacteria and archaea. Habitats with extreme temperatures alone appeared to be able to support a greater diversity of microbes than habitats with extreme pH or extreme chemical environments alone. Microbial diversity was lowest when habitats had both extreme temperature and one of these other extremes. In habitats with both extreme temperatures and extreme pH, taxa with known associations with extreme conditions dominated. Our findings highlight the importance of examining interactive effects of multiple environmental extremes on microbial communities. Inasmuch as taxa from extreme environments can be both beneficial and harmful to humans, our findings also suggest future work to understand both the threats and opportunities posed by the life in these habitats.
Tanhoffer, Ricardo A; Tanhoffer, Aldre I P; Raymond, Jacqueline; Hills, Andrew P; Davis, Glen M
2012-01-01
To compare different methods of assessing energy expenditure (EE) and physical activity (PA) in people with spinal cord injury (SCI) under community-dwelling conditions. A reference standard encompassing the doubly labelled water (DLW) technique, heart rate monitoring (FLEX-HR), a multi-sensor armband (SenseWear Armband (SWA)), and two PA recall questionnaires were employed in 14 people with SCI to estimate EE and leisure-time PA. Mean total daily energy expenditure (TDEE) assessed by DLW, FLEX-HR, and SWA were 9817 ± 2491 kJ/day, 8498 ± 1516 kJ/day, and 11414 ± 3242 kJ/day, respectively. Physical activity energy expenditure (PAEE) quantified by DLW was 2841 ± 1626 kJ/day, 2935 ± 1732 kJ/day estimated from FLEX-HR, and 2773 ± 2966 kJ/day derived from SWA. After converting the PA recall questionnaire data to EE in kJ/day, PAEE for the Physical Activity Recall Assessment for People with Spinal Cord Injury (PARA-SCI) was 2339 ± 1171 kJ/day and for Physical Activity Scale for Individuals with Physical Disabilities (PASIPD) 749 ± 1026 kJ/day. DLW-quantified PAEE was moderately associated with PARA-SCI (R(2) = 0.62, P < 0.05), but not with the other estimates of PAEE (R(2) ranged between 0.13 and 0.30, P > 0.05). Our findings revealed that the PARA-SCI recall questionnaire was the best estimate of PAEE compared to the reference standard DLW approach. Although the between-method variability for SWA, FLEX-HR, and PASIPD-derived PAEE was small, there was a weak association between these methods and the criterion DLW technique. The best estimate of DLW-quantified TDEE was by FLEX-HR. SWA significantly overestimated TDEE in this population.
Butler, T J; Kilbreath, S L; Gorman, R B; Gandevia, S C
2005-08-15
Flexor digitorum superficialis (FDS) is an extrinsic multi-tendoned muscle which flexes the proximal interphalangeal joints of the four fingers. It comprises four digital components, each with a tendon that inserts onto its corresponding finger. To determine the degree to which these digital components can be selectively recruited by volition, we recorded the activity of a single motor unit in one component via an intramuscular electrode while the subject isometrically flexed each of the remaining fingers, one at a time. The finger on which the unit principally acted was defined as the 'test finger' and that which flexed isometrically was the 'active' finger. Activity in 79 units was recorded. Isometric finger flexion forces of 50% maximum voluntary contraction (MVC) activated less than 50% of single units in components of FDS acting on fingers that were not voluntarily flexed. With two exceptions, the median recruitment threshold for all active-test finger combinations involving the index, middle, ring and little finger test units was between 49 and 60% MVC (60% MVC being the value assigned to those not recruited). The exceptions were flexion of the little finger while recording from ring finger units (median: 40% MVC), and vice versa (median: 2% MVC). For all active-test finger combinations, only 35/181 units were activated when the active finger flexed at less than 20% MVC, and the fingers were adjacent for 28 of these. Functionally, to recruit FDS units during grasping and lifting, relatively heavy objects were required, although systematic variation occurred with the width of the object. In conclusion, FDS components can be selectively activated by volition and this may be especially important for grasping at high forces with one or more fingers.
Niobium flex cable for low temperature high density interconnects
NASA Astrophysics Data System (ADS)
van Weers, H. J.; Kunkel, G.; Lindeman, M. A.; Leeman, M.
2013-05-01
This work describes the fabrication and characterization of a Niobium on polyimide flex cable suitable for sub-Kelvin temperatures. The processing used can be extended to high density interconnects and allows for direct integration with printed circuit boards. Several key parameters such as RRR, Tc, current carrying capability at 4 K and thermal conductivity in the range from 0.15 to 10 K have been measured. The average Tc was found to be 8.9 K, with a minimum of 8.3 K. Several samples allowed for more than 50 mA current at 4 K while remaining in the superconducting state. The thermal conductivity for this flex design is dominated by the polyimide, in our case Pyralin PI-2611, and is in good agreement with published thermal conductivity data for a polyimide called Upilex R. Registered trademark of Ube Industries, Japan.
A Goniometry Paradigm Shift to Measure Burn Scar Contracture in Burn Patients
2015-10-01
is based on an integumentary or cutaneous model; the hallmark difference being that natural skin is a single, continuous piece of tissue without...Position: Subject lying supine, hip flexed to 90 degrees, ankle relaxed , opposite leg extended and supported. Stabilization: Stabilize the femur in 90...clearance when knee is flexed), hip flexed to 55 degrees and stabilized with foam wedge (may secure with strap), ankle relaxed , opposite leg extended
Extreme Environments: The Ghetto and the South Pole.
ERIC Educational Resources Information Center
Pierce, Chester M.
Extreme environments, such as polar regions or space crafts, provide an analogue for speculations concerning the needs of, educational provisions for, and environmental impacts on ghetto youth in kindergarten through the third grade. This discussion first centers on the common qualities of an extreme environment (whether exotic or mundane): forced…
A Neuroscience Approach to Optimizing Brain Resources for Human Performance in Extreme Environments
Paulus, Martin P.; Potterat, Eric G.; Taylor, Marcus K.; Van Orden, Karl F.; Bauman, James; Momen, Nausheen; Padilla, Genieleah A.; Swain, Judith L.
2009-01-01
Extreme environments requiring optimal cognitive and behavioral performance occur in a wide variety of situations ranging from complex combat operations to elite athletic competitions. Although a large literature characterizes psychological and other aspects of individual differences in performances in extreme environments, virtually nothing is known about the underlying neural basis for these differences. This review summarizes the cognitive, emotional, and behavioral consequences of exposure to extreme environments, discusses predictors of performance, and builds a case for the use of neuroscience approaches to quantify and understand optimal cognitive and behavioral performance. Extreme environments are defined as an external context that exposes individuals to demanding psychological and/or physical conditions, and which may have profound effects on cognitive and behavioral performance. Examples of these types of environments include combat situations, Olympic-level competition, and expeditions in extreme cold, at high altitudes, or in space. Optimal performance is defined as the degree to which individuals achieve a desired outcome when completing goal-oriented tasks. It is hypothesized that individual variability with respect to optimal performance in extreme environments depends on a well “contextualized” internal body state that is associated with an appropriate potential to act. This hypothesis can be translated into an experimental approach that may be useful for quantifying the degree to which individuals are particularly suited to performing optimally in demanding environments. PMID:19447132
Sleutjens, Janneke; Smiet, Esmee; van Weeren, René; van der Kolk, Johannes; Back, Willem; Wijnberg, Inge D
2012-04-01
To evaluate the effect of various head and neck positions on intrathoracic pressure and arterial oxygenation during exercise in horses. 7 healthy Dutch Warmblood riding horses. The horses were evaluated with the head and neck in the following predefined positions: position 1, free and unrestrained; position 2, neck raised with the bridge of the nose aligned vertically; position 4, neck lowered and extremely flexed with the nose pointing toward the pectoral muscles; position 5, neck raised and extended with the bridge of the nose in front of a vertical line perpendicular to the ground surface; and position 7, neck lowered and flexed with the nose pointing towards the carpus. The standard exercise protocol consisted of trotting for 10 minutes, cantering for 4 minutes, trotting again for 5 minutes, and walking for 5 minutes. An esophageal balloon catheter was used to indirectly measure intrathoracic pressure. Arterial blood samples were obtained for measurement of Pao(2), Paco(2), and arterial oxygen saturation. Compared with when horses were in the unrestrained position, inspiratory intrathoracic pressure became more negative during the first trot (all positions), canter and second trot (position 4), and walk (positions 4 and 5). Compared with when horses were in position 1, intrathoracic pressure difference increased in positions 4, 2, 7, and 5; Pao(2) increased in position 5; and arterial oxygen saturation increased in positions 4 and 7. Position 4 was particularly influential on intrathoracic pressure during exercise in horses. The effects detected may have been caused by a dynamic upper airway obstruction and may be more profound in horses with upper airway disease.
NASA Astrophysics Data System (ADS)
Baier, Fabian; Gruber, Edith; Spangl, Bernhard; Zaller, Johann G.
2016-04-01
Herbicides based on the active ingredient glyphosate are frequently applied in agriculture, horticulture and private gardens all over the world. Recently, leaching of glyphosate or its metabolite (AMPA) into water bodies inhabited by amphibians has been reported. However, very little is known about non-target effects of these herbicides on amphibians and even less is known to what extent different temperatures might alter these effects. Using climate chambers, we investigated the effects of the glyphosate-based herbicide Roundup PowerFlex® (480 g L-1 glyphosate, formulated as 588 g L-1 potassium salt) on the larval development of Common toads (Bufo bufo L.; Amphibia: Anura) under different temperature regimes (15°C vs. 20°C). We established five herbicide concentrations: 0, 1.5, 3, 4 mg acid equivalent L-1 and a 4 mg a.e. L-1 pulse treatment (totally three applications of 1.5, 1.5 and another 1 mg a.e. L-1) at each temperature in a full-factorial design. Each treatment combination was replicated five times, the experiment ran for 24 days. Results showed a highly significant effect of temperature on body length and body width but no effect of herbicide concentration on these growth parameters. Moreover, highly significant interactions between herbicide and temperature on body length and body width were observed suggesting that herbicides had different effects on different temperatures. In conclusion, although Roundup PowerFlex® at the tested concentrations appeared to have no acute toxicity to larvae of Common toads, the observed effects on tadpole morphology will potentially affect competitive interactions in spawning ponds of amphibia. Our findings of herbicide x temperature interactions might become more prevalent when human-induced climate change will lead to more extreme temperatures.
Flexible Method for Developing Tactics, Techniques, and Procedures for Future Capabilities
2009-02-01
levels of ability, military experience, and motivation, (b) number and type of significant events, and (c) other sources of natural variability...research has developed a number of specific instruments designed to aid in this process. Second, the iterative, feed-forward nature of the method allows...FLEX method), but still lack the structured KE approach and iterative, feed-forward nature of the FLEX method. To facilitate decision making
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-22
... low-pressure flex-hoses of the crew oxygen system installed under the oxygen mask stowage boxes in the.... This proposed AD results from reports of low-pressure flex-hoses of the crew oxygen system that burned... the crew oxygen system to melt or burn, causing oxygen system leakage and smoke or fire. DATES: We...
NASA Astrophysics Data System (ADS)
Pulsani, B. R.
2017-11-01
Tank Information System is a web application which provides comprehensive information about minor irrigation tanks of Telangana State. As part of the program, a web mapping application using Flex and ArcGIS server was developed to make the data available to the public. In course of time as Flex be-came outdated, a migration of the client interface to the latest JavaScript based technologies was carried out. Initially, the Flex based application was migrated to ArcGIS JavaScript API using Dojo Toolkit. Both the client applications used published services from ArcGIS server. To check the migration pattern from proprietary to open source, the JavaScript based ArcGIS application was later migrated to OpenLayers and Dojo Toolkit which used published service from GeoServer. The migration pattern noticed in the study especially emphasizes upon the use of Dojo Toolkit and PostgreSQL database for ArcGIS server so that migration to open source could be performed effortlessly. The current ap-plication provides a case in study which could assist organizations in migrating their proprietary based ArcGIS web applications to open source. Furthermore, the study reveals cost benefits of adopting open source against commercial software's.
Evaluation and application of multiple scoring functions for a virtual screening experiment
NASA Astrophysics Data System (ADS)
Xing, Li; Hodgkin, Edward; Liu, Qian; Sedlock, David
2004-05-01
In order to identify novel chemical classes of factor Xa inhibitors, five scoring functions (FlexX, DOCK, GOLD, ChemScore and PMF) were engaged to evaluate the multiple docking poses generated by FlexX. The compound collection was composed of confirmed potent factor Xa inhibitors and a subset of the LeadQuest® screening compound library. Except for PMF the other four scoring functions succeeded in reproducing the crystal complex (PDB code: 1FAX). During virtual screening the highest hit rate (80%) was demonstrated by FlexX at an energy cutoff of -40 kJ/mol, which is about 40-fold over random screening (2.06%). Limited results suggest that presenting more poses of a single molecule to the scoring functions could deteriorate their enrichment factors. A series of promising scaffolds with favorable binding scores was retrieved from LeadQuest. Consensus scoring by pair-wise intersection failed to enrich the hit rate yielded by single scorings (i.e. FlexX). We note that reported successes of consensus scoring in hit rate enrichment could be artificial because their comparisons were based on a selected subset of single scoring and a markedly reduced subset of double or triple scoring. The findings presented in this report are based upon a single biological system and support further studies.
Reverse flexing as a physical/mechanical treatment to mitigate fouling of fine bubble diffusers.
Odize, Victory O; Novak, John; De Clippeleir, Haydee; Al-Omari, Ahmed; Smeraldi, Joshua D; Murthy, Sudhir; Rosso, Diego
2017-10-01
Achieving energy neutrality has shifted focus towards aeration system optimization, due to the high energy consumption of aeration processes in modern advanced wastewater treatment plants. A study on fine bubble diffuser fouling and mitigation, quantified by dynamic wet pressure (DWP), oxygen transfer efficiency and alpha was carried out in Blue Plains, Washington, DC. Four polyurethane fine bubble diffusers were installed in a pilot reactor column fed with high rate activated sludge from a full scale system. A mechanical cleaning method, reverse flexing (RF), was used to treat two diffusers (RF1, RF2), while two diffusers were kept as a control (i.e., no reverse flexing). There was a 45% increase in DWP of the control diffuser after 17 months of operation, an indication of fouling. RF treated diffusers (RF1 and RF2) did not show significant increase in DWP, and in comparison to the control diffuser prevented about 35% increase in DWP. Hence, reverse flexing potentially saves blower energy, by reducing the pressure burden on the air blower which increases blower energy requirement. However, no significant impact of the RF treatment in preventing a decrease in alpha-fouling (αF) of the fine pore diffusers, over time in operation was observed.
EcoFlex: A Multifunctional MoClo Kit for E. coli Synthetic Biology.
Moore, Simon J; Lai, Hung-En; Kelwick, Richard J R; Chee, Soo Mei; Bell, David J; Polizzi, Karen Marie; Freemont, Paul S
2016-10-21
Golden Gate cloning is a prominent DNA assembly tool in synthetic biology for the assembly of plasmid constructs often used in combinatorial pathway optimization, with a number of assembly kits developed specifically for yeast and plant-based expression. However, its use for synthetic biology in commonly used bacterial systems such as Escherichia coli has surprisingly been overlooked. Here, we introduce EcoFlex a simplified modular package of DNA parts for a variety of applications in E. coli, cell-free protein synthesis, protein purification and hierarchical assembly of transcription units based on the MoClo assembly standard. The kit features a library of constitutive promoters, T7 expression, RBS strength variants, synthetic terminators, protein purification tags and fluorescence proteins. We validate EcoFlex by assembling a 68-part containing (20 genes) plasmid (31 kb), characterize in vivo and in vitro library parts, and perform combinatorial pathway assembly, using pooled libraries of either fluorescent proteins or the biosynthetic genes for the antimicrobial pigment violacein as a proof-of-concept. To minimize pathway screening, we also introduce a secondary module design site to simplify MoClo pathway optimization. In summary, EcoFlex provides a standardized and multifunctional kit for a variety of applications in E. coli synthetic biology.
Elbow flexor fatigue modulates central excitability of the knee extensors.
Aboodarda, Saied Jalal; Copithorne, David B; Power, Kevin E; Drinkwater, Eric; Behm, David G
2015-09-01
The present study investigated the effects of exercise-induced elbow flexor fatigue on voluntary force output, electromyographic (EMG) activity and motoneurone excitability of the nonexercised knee extensor muscles. Eleven participants attended 3 testing sessions: (i) control, (ii) unilateral fatiguing elbow flexion and (iii) bilateral fatiguing elbow flexion (BiFlex). The nonfatigued knee extensor muscles were assessed with thoracic motor evoked potentials (TMEPs), maximal compound muscle action potential (Mmax), knee extensor maximal voluntary contractions (MVCs), and normalized EMG activity before and at 30 s, 3 min, and 5 min postexercise. BiFlex showed significantly lower (Δ = -18%, p = 0.03) vastus lateralis (VL) normalized EMG activity compared with the control session whereas knee extension MVC force did not show any statistical difference between the 3 conditions (p = 0.12). The TMEP·Mmax(-1) ratio measured at the VL showed a significantly higher value (Δ = +46%, p = 0.003) following BiFlex compared with the control condition at 30 s postexercise. The results suggest that the lower VL normalized EMG following BiFlex might have been due to a reduction in supraspinal motor output because spinal motoneuronal responses demonstrated substantially higher value (30 s postexercise) and peripheral excitability (compound muscle action potential) showed no change following BiFelex than control condition.
Flex Sensor Based Biofeedback Monitoring for Post-Stroke Fingers Myopathy Patients
NASA Astrophysics Data System (ADS)
Garda, Y. R.; Caesarendra, W.; Tjahjowidodo, T.; Turnip, A.; Wahyudati, S.; Nurhasanah, L.; Sutopo, D.
2018-04-01
Hands are one of the crucial parts of the human body in carrying out daily activities. Accidents on the hands decreasing in motor skills of the hand so that therapy is necessary to restore motor function of the hand. In addition to accidents, hand disabilities can be caused by certain diseases, e.g. stroke. Stroke is a partial destruction of the brain. It occurs if the arteries that drain blood to the brain are blocked, or if torn or leak. The purpose of this study to make biofeedback monitoring equipment for post-stroke hands myopathy patients. Biofeedback is an alternative method of treatment that involves measuring body functions measured subjects such as skin temperature, sweat activity, blood pressure, heart rate and hand paralysis due to stroke. In this study, the sensor used for biofeedback monitoring tool is flex sensor. Flex sensor is a passive resistive device that changes its resistance as the sensor is bent. Flex sensor converts the magnitude of the bend into electrical resistance, the greater the bend the greater the resistance value. The monitoring used in this biofeedback monitoring tool uses Graphical User Interface (GUI) in C# programming language. The motivation of the study is to monitor and record the progressive improvement of the hand therapy. Patients who experienced post-stroke can see the therapy progress quantitatively.
Advanced Space Suit Portable Life Support Subsystem Packaging Design
NASA Technical Reports Server (NTRS)
Howe, Robert; Diep, Chuong; Barnett, Bob; Thomas, Gretchen; Rouen, Michael; Kobus, Jack
2006-01-01
This paper discusses the Portable Life Support Subsystem (PLSS) packaging design work done by the NASA and Hamilton Sundstrand in support of the 3 future space missions; Lunar, Mars and zero-g. The goal is to seek ways to reduce the weight of PLSS packaging, and at the same time, develop a packaging scheme that would make PLSS technology changes less costly than the current packaging methods. This study builds on the results of NASA s in-house 1998 study, which resulted in the "Flex PLSS" concept. For this study the present EMU schematic (low earth orbit) was used so that the work team could concentrate on the packaging. The Flex PLSS packaging is required to: protect, connect, and hold the PLSS and its components together internally and externally while providing access to PLSS components internally for maintenance and for technology change without extensive redesign impact. The goal of this study was two fold: 1. Bring the advanced space suit integrated Flex PLSS concept from its current state of development to a preliminary design level and build a proof of concept mockup of the proposed design, and; 2. "Design" a Design Process, which accommodates both the initial Flex PLSS design and the package modifications, required to accommodate new technology.
Self-Recovery Experiments in Extreme Environments Using a Field Programmable Transistor Array
NASA Technical Reports Server (NTRS)
Stoica, Adrian; Keymeulen, Didier; Arslan, Tughrul; Duong, Vu; Zebulum, Ricardo; Ferguson, Ian; Guo, Xin
2004-01-01
Temperature and radiation tolerant electronics, as well as long life survivability are key capabilities required for future NASA missions. Current approaches to electronics for extreme environments focus on component level robustness and hardening. However, current technology can only ensure very limited lifetime in extreme environments. This paper describes novel experiments that allow adaptive in-situ circuit redesign/reconfiguration during operation in extreme temperature and radiation environments. This technology would complement material/device advancements and increase the mission capability to survive harsh environments. The approach is demonstrated on a mixed-signal programmable chip (FPTA-2), which recovers functionality for temperatures until 28 C and with total radiation dose up to 250kRad.
Very High Spectral Resolution Imaging Spectroscopy: the Fluorescence Explorer (FLEX) Mission
NASA Technical Reports Server (NTRS)
Moreno, Jose F.; Goulas, Yves; Huth, Andreas; Middleton, Elizabeth; Miglietta, Franco; Mohammed, Gina; Nedbal, Ladislav; Rascher, Uwe; Verhoef, Wouter; Drusch, Matthias
2016-01-01
The Fluorescence Explorer (FLEX) mission has been recently selected as the 8th Earth Explorer by the European Space Agency (ESA). It will be the first mission specifically designed to measure from space vegetation fluorescence emission, by making use of very high spectral resolution imaging spectroscopy techniques. Vegetation fluorescence is the best proxy to actual vegetation photosynthesis which can be measurable from space, allowing an improved quantification of vegetation carbon assimilation and vegetation stress conditions, thus having key relevance for global mapping of ecosystems dynamics and aspects related with agricultural production and food security. The FLEX mission carries the FLORIS spectrometer, with a spectral resolution in the range of 0.3 nm, and is designed to fly in tandem with Copernicus Sentinel-3, in order to provide all the necessary spectral / angular information to disentangle emitted fluorescence from reflected radiance, and to allow proper interpretation of the observed fluorescence spatial and temporal dynamics.
3-D Packaging: A Technology Review
NASA Technical Reports Server (NTRS)
Strickland, Mark; Johnson, R. Wayne; Gerke, David
2005-01-01
Traditional electronics are assembled as a planar arrangement of components on a printed circuit board (PCB) or other type of substrate. These planar assemblies may then be plugged into a motherboard or card cage creating a volume of electronics. This architecture is common in many military and space electronic systems as well as large computer and telecommunications systems and industrial electronics. The individual PCB assemblies can be replaced if defective or for system upgrade. Some applications are constrained by the volume or the shape of the system and are not compatible with the motherboard or card cage architecture. Examples include missiles, camcorders, and digital cameras. In these systems, planar rigid-flex substrates are folded to create complex 3-D shapes. The flex circuit serves the role of motherboard, providing interconnection between the rigid boards. An example of a planar rigid - flex assembly prior to folding is shown. In both architectures, the interconnection is effectively 2-D.
EcoFlex: A Multifunctional MoClo Kit for E. coli Synthetic Biology.
Lai, Hung-En; Moore, Simon; Polizzi, Karen; Freemont, Paul
2018-01-01
Development of advanced synthetic biology tools is always in demand since they act as a platform technology to enable rapid prototyping of biological constructs in a high-throughput manner. EcoFlex is a modular cloning (MoClo) kit for Escherichia coli and is based on the Golden Gate principles, whereby Type IIS restriction enzymes (BsaI, BsmBI, BpiI) are used to construct modular genetic elements (biological parts) in a bottom-up approach. Here, we describe a collection of plasmids that stores various biological parts including promoters, RBSs, terminators, ORFs, and destination vectors, each encoding compatible overhangs allowing hierarchical assembly into single transcription units or a full-length polycistronic operon or biosynthetic pathway. A secondary module cloning site is also available for pathway optimization, in order to limit library size if necessary. Here, we show the utility of EcoFlex using the violacein biosynthesis pathway as an example.
Extrinsic and intrinsic index finger muscle attachments in an OpenSim upper-extremity model.
Lee, Jong Hwa; Asakawa, Deanna S; Dennerlein, Jack T; Jindrich, Devin L
2015-04-01
Musculoskeletal models allow estimation of muscle function during complex tasks. We used objective methods to determine possible attachment locations for index finger muscles in an OpenSim upper-extremity model. Data-driven optimization algorithms, Simulated Annealing and Hook-Jeeves, estimated tendon locations crossing the metacarpophalangeal (MCP), proximal interphalangeal (PIP) and distal interphalangeal (DIP) joints by minimizing the difference between model-estimated and experimentally-measured moment arms. Sensitivity analysis revealed that multiple sets of muscle attachments with similar optimized moment arms are possible, requiring additional assumptions or data to select a single set of values. The most smooth muscle paths were assumed to be biologically reasonable. Estimated tendon attachments resulted in variance accounted for (VAF) between calculated moment arms and measured values of 78% for flex/extension and 81% for ab/adduction at the MCP joint. VAF averaged 67% at the PIP joint and 54% at the DIP joint. VAF values at PIP and DIP joints partially reflected the constant moment arms reported for muscles about these joints. However, all moment arm values found through optimization were non-linear and non-constant. Relationships between moment arms and joint angles were best described with quadratic equations for tendons at the PIP and DIP joints.
The force on the flex: Global parallelism and portability
NASA Technical Reports Server (NTRS)
Jordan, H. F.
1986-01-01
A parallel programming methodology, called the force, supports the construction of programs to be executed in parallel by an unspecified, but potentially large, number of processes. The methodology was originally developed on a pipelined, shared memory multiprocessor, the Denelcor HEP, and embodies the primitive operations of the force in a set of macros which expand into multiprocessor Fortran code. A small set of primitives is sufficient to write large parallel programs, and the system has been used to produce 10,000 line programs in computational fluid dynamics. The level of complexity of the force primitives is intermediate. It is high enough to mask detailed architectural differences between multiprocessors but low enough to give the user control over performance. The system is being ported to a medium scale multiprocessor, the Flex/32, which is a 20 processor system with a mixture of shared and local memory. Memory organization and the type of processor synchronization supported by the hardware on the two machines lead to some differences in efficient implementations of the force primitives, but the user interface remains the same. An initial implementation was done by retargeting the macros to Flexible Computer Corporation's ConCurrent C language. Subsequently, the macros were caused to directly produce the system calls which form the basis for ConCurrent C. The implementation of the Fortran based system is in step with Flexible Computer Corporations's implementation of a Fortran system in the parallel environment.
Lannin, Natasha A; Cusick, Anne; Hills, Caroline; Kinnear, Bianca; Vogel, Karin; Matthews, Kate; Bowring, Greg
2016-12-01
Assistive technologies have the potential to increase the amount of movement practice provided during inpatient stroke rehabilitation. The primary aim of this study was to investigate the feasibility of using the Saebo-Flex ™ device in a subacute stroke setting to increase task-specific practice for people with little or no active hand movement. The secondary aim was to collect preliminary data comparing hand/upper limb function between a control group that received usual rehabilitation and an intervention group that used, in addition, the Saebo-Flex ™ device. Nine inpatients (mean three months (median six weeks) post-stroke) participated in this feasibility study conducted in an Australian rehabilitation setting, using a randomised pre-test and post-test design with concealed allocation and blinded outcome assessment. In addition to usual rehabilitation, the intervention group received eight weeks of daily motor training using the Saebo-Flex ™ device. The control group received usual rehabilitation (task-specific motor training) only. Participants were assessed at baseline (pre-randomisation) and at the end of the eight-week study period. Feasibility was assessed with respect to ease of recruitment, application of the device, compliance with the treatment programme and safety. Secondary outcome measures included the Motor Assessment Scale (upper limb items), Box and Block Test, grip strength and the Stroke Impact Scale. Recruitment to the study was very slow because of the low number of patients with little or no active hand movement. Otherwise, the study was feasible in terms of being able to apply the Saebo-Flex ™ device and compliance with the treatment programme. There were no adverse events, and a greater amount of upper limb rehabilitation was provided to the intervention group. While there were trends in favour of the intervention group, particularly for dexterity, no between-group differences were seen for any of the secondary outcomes. This pilot feasibility study showed that the use of assistive technology, specifically the Saebo-Flex ™ device, could be successfully used in a sample of stroke patients with little or no active hand movement. However, recruitment to the trial was very slow. The use of the Saebo-Flex TM device had variable results on outcomes, with some positive trends seen in hand function, particularly dexterity. © 2016 Occupational Therapy Australia.
Wearable Activity Tracker Use Among Australian Adolescents: Usability and Acceptability Study.
Ridgers, Nicola D; Timperio, Anna; Brown, Helen; Ball, Kylie; Macfarlane, Susie; Lai, Samuel K; Richards, Kara; Mackintosh, Kelly A; McNarry, Melitta A; Foster, Megan; Salmon, Jo
2018-04-11
Wearable activity trackers have the potential to be integrated into physical activity interventions, yet little is known about how adolescents use these devices or perceive their acceptability. The aim of this study was to examine the usability and acceptability of a wearable activity tracker among adolescents. A secondary aim was to determine adolescents' awareness and use of the different functions and features in the wearable activity tracker and accompanying app. Sixty adolescents (aged 13-14 years) in year 8 from 3 secondary schools in Melbourne, Australia, were provided with a wrist-worn Fitbit Flex and accompanying app, and were asked to use it for 6 weeks. Demographic data (age, sex) were collected via a Web-based survey completed during week 1 of the study. At the conclusion of the 6-week period, all adolescents participated in focus groups that explored their perceptions of the usability and acceptability of the Fitbit Flex, accompanying app, and Web-based Fitbit profile. Qualitative data were analyzed using pen profiles, which were constructed from verbatim transcripts. Adolescents typically found the Fitbit Flex easy to use for activity tracking, though greater difficulties were reported for monitoring sleep. The Fitbit Flex was perceived to be useful for tracking daily activities, and adolescents used a range of features and functions available through the device and the app. Barriers to use included the comfort and design of the Fitbit Flex, a lack of specific feedback about activity levels, and the inability to wear the wearable activity tracker for water-based sports. Adolescents reported that the Fitbit Flex was easy to use and that it was a useful tool for tracking daily activities. A number of functions and features were used, including the device's visual display to track and self-monitor activity, goal-setting in the accompanying app, and undertaking challenges against friends. However, several barriers to use were identified, which may impact on sustained use over time. Overall, wearable activity trackers have the potential to be integrated into physical activity interventions targeted at adolescents, but both the functionality and wearability of the monitor should be considered. ©Nicola D Ridgers, Anna Timperio, Helen Brown, Kylie Ball, Susie Macfarlane, Samuel K Lai, Kara Richards, Kelly A Mackintosh, Melitta A McNarry, Megan Foster, Jo Salmon. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 11.04.2018.
NASA Technical Reports Server (NTRS)
Rutledge, Sharon K.; Ciancone, Michael L.; Paulsen, Phillip E.; Brady, Joyce A.
1988-01-01
The extent of degradation of fiberglass-epoxy composite masts of the Space Station solar array panel, when these are exposed to atomic oxygen environment of the low-earth orbit, was investigated in ground testing of fiberglass-epoxy composites in an RF plasma asher. In addition, several methods of protecting the composite structures were evaluated, including an aluminum braid covering, an In-Sn eutectic, and a silicone based paint. It was found that, during exposure, the epoxy at the surface of the composite was oxidized, exposing individual glass fibers which could easily be removed. The results of mass measurements and SEM examination carried out after thermal cycling and flexing of exposed composite samples indicated that coatings such as In-Sn eutectic may provide adequate protection by containing the glass fibers, even though mass loss still occurs.
2015-05-13
ISS043E190395 (05/13/2015) --- NASA astronaut Terry Virts prepares the Multi-user Droplet Combustion Apparatus from inside the Combustion Integrated Rack for upcoming runs of the FLame Extinguishment Experiment, or FLEX-2. The FLEX-2 experiment studies how quickly fuel burns, the conditions required for soot to form, and how mixtures of fuels evaporate before burning. Understanding these processes could lead to the production of a safer spacecraft as well as increased fuel efficiency for engines using liquid fuel on Earth.
2016-10-01
satisfaction with device’’ (i.e. prosthesis) than the IC Socket. During year 1, we received all required IRB approvals, registered the clinical... satisfaction with device” (i.e. prosthesis) than the IC Socket. 2. KEYWORDS: Prosthetic Socket, Artificial Limbs, Prosthesis, Transfemoral Amputee, Gait...FlexSIV Socket will result in better quality of life and “ satisfaction with device” (i.e. prosthesis) than the IC socket. Accomplishments under
McFarland, Joshua C; Meyers, Ron A
2008-08-01
Birds utilize one of two hindlimb postures during flight: an extended posture (with the hip and knee joints flexed, while the ankle joint is extended caudally) or a flexed posture (with the hip, knee, and ankle joints flexed beneath the body). American Avocets (Recurvirostra americana) and Black-necked Stilts (Himantopus mexicanus) extend their legs caudally during flight and support them for extended periods. Slow tonic and slow twitch muscle fibers are typically found in muscles functioning in postural support due to the fatigue resistance of these fibers. We hypothesized that a set of small muscles composed of high percentages of slow fibers and thus dedicated to postural support would function in securing the legs in the extended posture during flight. This study examined the anatomy and histochemical profile of eleven hindlimb muscles to gain insight into their functional roles during flight. Contrary to our hypothesis, all muscles possessed both fast twitch and slow twitch or slow tonic fibers. We believe this finding is due to the versatility of dynamic and postural functions the leg muscles must facilitate, including standing, walking, running, swimming, and hindlimb support during flight. Whether birds use an extended or flexed hindlimb flight posture may be related to the aerodynamic effect of leg position or may reflect evolutionary history. (c) 2008 Wiley-Liss, Inc.
Kinematic repeatability of a multi-segment foot model for dance.
Carter, Sarah L; Sato, Nahoko; Hopper, Luke S
2018-03-01
The purpose of this study was to determine the intra and inter-assessor repeatability of a modified Rizzoli Foot Model for analysing the foot kinematics of ballet dancers. Six university-level ballet dancers performed the movements; parallel stance, turnout plié, turnout stance, turnout rise and flex-point-flex. The three-dimensional (3D) position of individual reflective markers and marker triads was used to model the movement of the dancers' tibia, entire foot, hindfoot, midfoot, forefoot and hallux. Intra and inter-assessor reliability demonstrated excellent (ICC ≥ 0.75) repeatability for the first metatarsophalangeal joint in the sagittal plane. Intra-assessor reliability demonstrated excellent (ICC ≥ 0.75) repeatability during flex-point-flex across all inter-segmental angles except for the tibia-hindfoot and hindfoot-midfoot frontal planes. Inter-assessor repeatability ranged from poor to excellent (0.5 > ICC ≥ 0.75) for the 3D segment rotations. The most repeatable measure was the tibia-foot dorsiflexion/plantar flexion articulation whereas the least repeatable measure was the hindfoot-midfoot adduction/abduction articulation. The variation found in the inter-assessor results is likely due to inconsistencies in marker placement. This 3D dance specific multi-segment foot model provides insight into which kinematic measures can be reliably used to ascertain in vivo technical errors and/or biomechanical abnormalities in a dancer's foot motion.
Mechanical characterization and comparison of energy storage and return prostheses.
Rigney, Stacey M; Simmons, Anne; Kark, Lauren
2017-03-01
The suitability of finite element analysis (FEA) for standardizing the mechanical characterization of energy storage and return (ESAR) prostheses was investigated. A methodology consisting of both experimental and numerical analysis was proposed and trialed for the Vari-flex ® Modular TM , Flex-foot Cheetah and Cheetah Xtreme by Össur ® and a 1E90 Sprinter by Ottobock ® . Gait analysis was conducted to determine suitable orientation angles for non-destructive testing (NDT) of the ESAR prostheses followed by a quasi-static inverse FEA procedure within COMSOL Multiphysics ® , where the NDT conditions were replicated to determine the homogenized material properties of the prostheses. The prostheses' loading response under bodyweight for an 80kg person was then simulated, using both Eigenfrequency and time-dependent analysis. The apparent stiffness under bodyweight was determined to be 94.7, 48.6, 57.4 and 65.0Nmm -1 for the Vari-flex ® Modular TM , Flex-foot Cheetah, Cheetah Xtreme and 1E90 Sprinter, respectively. Both the energy stored and returned by the prostheses varied negatively with stiffness, yet the overall efficiency of the prostheses were similar, at 52.7, 52.0, 51.7 and 52.4% for the abovementioned prostheses. The proposed methodology allows the standardized assessment and comparison of ESAR prostheses without the confounding influences of subject-specific gait characteristics. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.
Shankarappa, Pushpa; Misra, Abhinav; Sawhney, Asheesh; Sridevi, Nandamuri; Singh, Anu
2016-01-01
Introduction. The aim of the present study was to evaluate the dentinal cracks after root canal preparation with rotary files: Gates Glidden, ProTaper Universal, ProTaper Next, and HyFlex CM at different instrumentation lengths. Methodology. Sixty-five mandibular premolars were mounted in the acrylic tube with simulated periodontal ligaments and the apex was exposed. The root canals were instrumented with different rotary files, namely, ProTaper Universal, ProTaper Next, and HyFlex CM, to the major apical foramen (AF), short AF, and beyond AF. The root apex was stained with 1% methylene blue dye and digital images of apical surface of every tooth were taken and development of dentinal defects was determined by using stereomicroscope. Multinomial logistic regression test was performed to identify influencing factors. Results. Instrumentation with rotary files terminated 2 mm short AF and did not cause any cracks. Significantly less cracks were seen when instrumentation with rotary files terminated 1 mm short apical foramen when compared with the instrumentation terminated at or beyond apical foramen (p < 0.05). Conclusion. ProTaper Universal rotary files caused more dentinal cracks than ProTaper Next and HyFlex CM. Instrumentation short AF reduced the risk of dentinal defects. PMID:27446636
Rahman, Mizanur; Hewitt, Jennifer E; Van-Bussel, Frank; Edwards, Hunter; Blawzdziewicz, Jerzy; Szewczyk, Nathaniel J; Driscoll, Monica; Vanapalli, Siva A
2018-06-12
Muscle strength is a functional measure of quality of life in humans. Declines in muscle strength are manifested in diseases as well as during inactivity, aging, and space travel. With conserved muscle biology, the simple genetic model C. elegans is a high throughput platform in which to identify molecular mechanisms causing muscle strength loss and to develop interventions based on diet, exercise, and drugs. In the clinic, standardized strength measures are essential to quantitate changes in patients; however, analogous standards have not been recapitulated in the C. elegans model since force generation fluctuates based on animal behavior and locomotion. Here, we report a microfluidics-based system for strength measurement that we call 'NemaFlex', based on pillar deflection as the nematode crawls through a forest of pillars. We have optimized the micropillar forest design and identified robust measurement conditions that yield a measure of strength that is independent of behavior and gait. Validation studies using a muscle contracting agent and mutants confirm that NemaFlex can reliably score muscular strength in C. elegans. Additionally, we report a scaling factor to account for animal size that is consistent with a biomechanics model and enables comparative strength studies of mutants. Taken together, our findings anchor NemaFlex for applications in genetic and drug screens, for defining molecular and cellular circuits of neuromuscular function, and for dissection of degenerative processes in disuse, aging, and disease.
Attachment method for stacked integrated circuit (IC) chips
Bernhardt, Anthony F.; Malba, Vincent
1999-01-01
An attachment method for stacked integrated circuit (IC) chips. The method involves connecting stacked chips, such as DRAM memory chips, to each other and/or to a circuit board. Pads on the individual chips are rerouted to form pads on the side of the chip, after which the chips are stacked on top of each other whereby desired interconnections to other chips or a circuit board can be accomplished via the side-located pads. The pads on the side of a chip are connected to metal lines on a flexible plastic tape (flex) by anisotropically conductive adhesive (ACA). Metal lines on the flex are likewise connected to other pads on chips and/or to pads on a circuit board. In the case of a stack of DRAM chips, pads to corresponding address lines on the various chips may be connected to the same metal line on the flex to form an address bus. This method has the advantage of reducing the number of connections required to be made to the circuit board due to bussing; the flex can accommodate dimensional variation in the alignment of chips in the stack; bonding of the ACA is accomplished at low temperature and is otherwise simpler and less expensive than solder bonding; chips can be bonded to the ACA all at once if the sides of the chips are substantially coplanar, as in the case for stacks of identical chips, such as DRAM.
Load responsive hydrodynamic bearing
Kalsi, Manmohan S.; Somogyi, Dezso; Dietle, Lannie L.
2002-01-01
A load responsive hydrodynamic bearing is provided in the form of a thrust bearing or journal bearing for supporting, guiding and lubricating a relatively rotatable member to minimize wear thereof responsive to relative rotation under severe load. In the space between spaced relatively rotatable members and in the presence of a liquid or grease lubricant, one or more continuous ring shaped integral generally circular bearing bodies each define at least one dynamic surface and a plurality of support regions. Each of the support regions defines a static surface which is oriented in generally opposed relation with the dynamic surface for contact with one of the relatively rotatable members. A plurality of flexing regions are defined by the generally circular body of the bearing and are integral with and located between adjacent support regions. Each of the flexing regions has a first beam-like element being connected by an integral flexible hinge with one of the support regions and a second beam-like element having an integral flexible hinge connection with an adjacent support region. A least one local weakening geometry of the flexing region is located intermediate the first and second beam-like elements. In response to application of load from one of the relatively rotatable elements to the bearing, the beam-like elements and the local weakening geometry become flexed, causing the dynamic surface to deform and establish a hydrodynamic geometry for wedging lubricant into the dynamic interface.
2016-04-01
SUBJECT TERMS carbon nanotubes, composite, electromagnetic shielding , extreme environments, magnetism , fibers, woven composite, boron nitride...AFRL-AFOSR-VA-TR-2016-0158 Magnetic -Field-Assisted Assembly of Ordered Multifunctional Ceramic Nanocomposites for Extreme Environments Konstantin...From - To) 15 Sep 2012 to 14 Nov 2017 4. TITLE AND SUBTITLE Magnetic -Field-Assisted Assembly of Ordered Multifunctional Ceramic Nanocomposites for
Tang, X; Liu, H; Chen, L; Wang, Q; Luo, B; Xiang, N; He, Y; Zhu, W; Zhang, J
2018-05-24
To investigate the accuracy of two semi-automatic segmentation measurements based on magnetic resonance imaging (MRI) three-dimensional (3D) Cube fast spin echo (FSE)-flex sequence in phantoms, and to evaluate the feasibility of determining the volumetric alterations of orbital fat (OF) and total extraocular muscles (TEM) in patients with thyroid-associated ophthalmopathy (TAO) by semi-automatic segmentation. Forty-four fatty (n=22) and lean (n=22) phantoms were scanned by using Cube FSE-flex sequence with a 3 T MRI system. Their volumes were measured by manual segmentation (MS) and two semi-automatic segmentation algorithms (regional growing [RG], multi-dimensional threshold [MDT]). Pearson correlation and Bland-Altman analysis were used to evaluate the measuring accuracy of MS, RG, and MDT in phantoms as compared with the true volume. Then, OF and TEM volumes of 15 TAO patients and 15 normal controls were measured using MDT. Paired-sample t-tests were used to compare the volumes and volume ratios of different orbital tissues between TAO patients and controls. Each segmentation (MS RG, MDT) has a significant correlation (p<0.01) with true volume. There was a minimal bias for MS, and a stronger agreement between MDT and the true volume than RG and the true volume both in fatty and lean phantoms. The reproducibility of Cube FSE-flex determined MDT was adequate. The volumetric ratios of OF/globe (p<0.01), TEM/globe (p<0.01), whole orbit/globe (p<0.01) and bone orbit/globe (p<0.01) were significantly greater in TAO patients than those in healthy controls. MRI Cube FSE-flex determined MDT is a relatively accurate semi-automatic segmentation that can be used to evaluate OF and TEM volumes in clinic. Copyright © 2018 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Tanhoffer, Ricardo A.; Tanhoffer, Aldre I. P.; Raymond, Jacqueline; Hills, Andrew P.; Davis, Glen M.
2012-01-01
Objective To compare different methods of assessing energy expenditure (EE) and physical activity (PA) in people with spinal cord injury (SCI) under community-dwelling conditions. Methods A reference standard encompassing the doubly labelled water (DLW) technique, heart rate monitoring (FLEX-HR), a multi-sensor armband (SenseWear Armband (SWA)), and two PA recall questionnaires were employed in 14 people with SCI to estimate EE and leisure-time PA. Results Mean total daily energy expenditure (TDEE) assessed by DLW, FLEX-HR, and SWA were 9817 ± 2491 kJ/day, 8498 ± 1516 kJ/day, and 11414 ± 3242 kJ/day, respectively. Physical activity energy expenditure (PAEE) quantified by DLW was 2841 ± 1626 kJ/day, 2935 ± 1732 kJ/day estimated from FLEX-HR, and 2773 ± 2966 kJ/day derived from SWA. After converting the PA recall questionnaire data to EE in kJ/day, PAEE for the Physical Activity Recall Assessment for People with Spinal Cord Injury (PARA-SCI) was 2339 ± 1171 kJ/day and for Physical Activity Scale for Individuals with Physical Disabilities (PASIPD) 749 ± 1026 kJ/day. DLW-quantified PAEE was moderately associated with PARA-SCI (R2 = 0.62, P < 0.05), but not with the other estimates of PAEE (R2 ranged between 0.13 and 0.30, P > 0.05). Conclusion Our findings revealed that the PARA-SCI recall questionnaire was the best estimate of PAEE compared to the reference standard DLW approach. Although the between-method variability for SWA, FLEX-HR, and PASIPD-derived PAEE was small, there was a weak association between these methods and the criterion DLW technique. The best estimate of DLW-quantified TDEE was by FLEX-HR. SWA significantly overestimated TDEE in this population. PMID:22330189
The Flex Track: Flexible Partitioning between Low- and High-Acuity Areas of an Emergency Department
Laker, Lauren F.; Froehle, Craig M.; Lindsell, Christopher J.; Ward, Michael J.
2014-01-01
Study Objective EDs with both low- and high-acuity treatment areas often have fixed allocation of resources, regardless of demand. We demonstrate the utility of discrete-event simulation to evaluate flexible partitioning between low- and high-acuity ED areas to identify the best operational strategy for subsequent implementation. Methods A discrete-event simulation was used to model patient flow through a 50-bed, urban, teaching ED that handles 85,000 patient visits annually. The ED has historically allocated ten beds to a Fast Track for low-acuity patients. We estimated the effect of a Flex Track policy, which involved switching up to five of these Fast Track beds to serving both low- and high-acuity patients, on patient waiting times. When the high-acuity beds were not at capacity, low-acuity patients were given priority access to flexible beds. Otherwise, high-acuity patients were given priority access to flexible beds. Wait times were estimated for patients by disposition and emergency severity index (ESI) score. Results A Flex Track policy using three flexible beds produced the lowest mean patient waiting of 30.9 (95% CI 30.6–31.2) minutes. The typical Fast Track approach of rigidly separating high- and low–acuity beds produced a mean patient wait time of 40.6 (95% CI 40.2–50.0) minutes, 31% higher than the three-bed Flex Track. A completely flexible ED, where all beds can accommodate any patient, produced mean wait times of 35.1 (95% CI 34.8–35.4) minutes. The results from the three-bed Flex Track scenario were robust, performing well across a range of scenarios involving higher and lower patient volumes and care durations. Conclusion Using discrete-event simulation, we have shown that adding some flexibility into bed allocation between low- and high-acuity can provide substantial reductions in overall patient waiting and a more efficient ED. PMID:24954578
A study on FlexMaster : a Ni-Ti rotary engine driven system for root canal preparation.
Alam, M S; Bashar, A K; Begumr, J A; Kinoshita, J I
2006-07-01
In the present study, the effectiveness of recently introduced rotary Nickel Titanium FlexMaster engine driven system was evaluated for cleaning and shaping of root canals in extracted human teeth and compared with that done by the Nickel Titanium Flexofile hand instruments. A total of 40 root canals from 36 extracted mandibular and maxillary teeth with curvature ranging between 20 and 30 degree were divided into two groups, consisting 20 canals in each. FlexMaster instrumentation was done in 20 canals, using crown-down technique and manual filing with Flexofile was done in other 20 canals, using conventional and step-back techniques. 5.25% sodium hypochlorite (NaOCl) solution and 17% ethelene di-amine tetra-acetic acid (EDTA) were used alternatively for irrigation after canal preparation by each instrument size. Time needed for canal preparation of individual canal was recorded. A procedural error such as instrument breakage was also noted. After preparation, all the roots were cut longitudinally by using diamond burs in turbine handpiece and examined under scanning electron microscope. Apical region was quantified for debris and smear layer based on a 5-score numerical evaluation scale. The data established for scoring the debris and smear layer and preparation time of individual canal were analyzed statistically using the Mann-Whitney U test. Completely cleaned root canals were not found with any of the two instruments and none of the instruments maintained the original canal uniformity and regular dentine surface. Because significantly less debris was found in the apical region using the manual filing technique (p< 0.05). Thus the flexmaster system was found to produce less cleaner root canal walls than manual technique. Only one FlexMaster finishing file sized 30 was separated in the apical region during preparation of 30 degree curved canal. The time taken by FlexMaster was significantly better (p< 0.01) than that of hand instruments.
Sasada, Shinji; Izumo, Takehiro; Matsumoto, Yuji; Tsuchida, Takaaki
2016-01-01
Background Some trials recently demonstrated the benefit of targeted treatment for malignant disease; therefore, adequate tissues are needed to detect the targeted gene. Pleural biopsy using flex-rigid pleuroscopy and pleural effusion cell block analysis are both useful for diagnosis of malignancy and obtaining adequate samples. The purpose of our study was to compare the diagnostic utility between the two methods among patients with malignant pleural disease with effusion. Methods Data from patients who underwent flex-rigid pleuroscopy for diagnosis of pleural effusion suspicious for malignancy at the National Cancer Center Hospital, Japan between April 2011 and June 2014 were retrospectively reviewed. All procedures were performed under local anesthesia. At least 150 mL of pleural fluid was collected by pleuroscopy, followed by pleural biopsies from the abnormal site. Results Thirty-five patients who were finally diagnosed as malignant pleural disease were included in this study. Final diagnoses of malignancy were 24 adenocarcinoma, 1 combined adeno-small cell carcinoma, and 7 malignant pleural mesothelioma (MPM), and 3 metastatic breast cancer. The diagnostic yield was significantly higher by pleural biopsy than by cell block [94.2% (33/35) vs. 71.4% (25/35); p = 0.008]. All patients with positive results on cell block also had positive results on pleural biopsy. Eight patients with negative results on cell block had positive results on pleural biopsy (lung adenocarcinoma in 4, sarcomatoid MPM in 3, and metastatic breast cancer in 1). Two patients with negative results on both cell block and pleural biopsy were diagnosed was sarcomatoid MPM by computed tomography-guided needle biopsy and epithelioid MPM by autopsy. Conclusion Pleural biopsy using flex-rigid pleuroscopy was efficient in the diagnosis of malignant pleural diseases. Flex-rigid pleuroscopy with pleural biopsy and pleural effusion cell block analysis should be considered as the initial diagnostic approach for malignant pleural diseases presenting with effusion. PMID:27880851
Analysis of muscle activation in lower extremity for static balance.
Chakravarty, Kingshuk; Chatterjee, Debatri; Das, Rajat Kumar; Tripathy, Soumya Ranjan; Sinha, Aniruddha
2017-07-01
Balance plays an important role for human bipedal locomotion. Degeneration of balance control is prominent in stroke patients, elderly adults and even for majority of obese people. Design of personalized balance training program, in order to strengthen muscles, requires the analysis of muscle activation during an activity. In this paper we have proposed an affordable and portable approach to analyze the relationship between the static balance strategy and activation of various lower extremity muscles. To do that we have considered Microsoft Kinect XBox 360 as a motion sensing device and Wii balance board for measuring external force information. For analyzing the muscle activation pattern related to static balance, participants are asked to do the single limb stance (SLS) exercise on the balance board and in front of the Kinect. Static optimization to minimize the overall muscle activation pattern is carried out using OpenSim, which is an open-source musculoskeletal simulation software. The study is done on ten normal and ten obese people, grouped according to body mass index (BMI). Results suggest that the lower extremity muscles like biceps femoris, psoas major, sartorius, iliacus play the major role for both maintaining the balance using one limb as well as maintaining the flexion of the other limb during SLS. Further investigations reveal that the higher muscle activations of the flexed leg for normal group demonstrate higher strength. Moreover, the lower muscle activation of the standing leg for normal group demonstrate more headroom for the biceps femoris-short-head and psoas major to withstand the load and hence have better static balance control.
Wright, Catherine M; Duquesnay, Paula J; Anzman-Frasca, Stephanie; Chomitz, Virginia R; Chui, Kenneth; Economos, Christina D; Langevin, Elizabeth G; Nelson, Miriam E; Sacheck, Jennifer M
2016-10-13
Physical activity (PA) is critical to preventing childhood obesity and contributes to children's overall physical and cognitive health, yet fewer than half of all children achieve the recommended 60 min per day of moderate-to-vigorous physical activity (MVPA). Schools are an ideal setting to meeting PA guidelines, but competing demands and limited resources have impacted PA opportunities. The Fueling Learning through Exercise (FLEX) Study is a randomized controlled trial that will evaluate the impact of two innovative school-based PA programs on children's MVPA, cognitive function, and academic outcomes. Twenty-four public elementary schools from low-income, ethnically diverse communities around Massachusetts were recruited and randomized to receive either 100 Mile Club® (walking/running program) or Just Move™ (classroom-based PA program) intervention, or control. Schoolchildren (grades 3-4, approximately 50 per school) were recruited to participate in evaluation. Primary outcome measures include PA via 7-day accelerometry (Actigraph GT3X+ and wGT3X-BT), cognitive assessments, and academic achievement via state standardized test scores. Additional measures include height and weight, surveys assessing psycho-social factors related to PA, and dietary intake. School-level surveys assess PA infrastructure and resources and intervention implementation. Data are collected at baseline, mid-point (5-6 months post-baseline), and post-intervention (approximately 1.5 years post-baseline). Demographic data were collected by parents/caregivers at baseline. Mixed-effect models will test the short- and long-term effects of both programs on minutes spent in MVPA, as well as secondary outcomes including cognitive and academic outcomes. The FLEX study will evaluate strategies for increasing children's MVPA through two innovative, low-cost, school-based PA programs as well as their impact on children's cognitive functioning and academic success. Demonstration of a relationship between school-based MVPA with neutral or improved, rather than diminished, academic outcomes in a naturalistic environment has the potential to positively influence investment in school PA programs and initiatives. ClinicalTrials.gov Identifier: NCT02810834 . Registered May 11, 2015. (Retrospectively registered).
PISCES: An environment for parallel scientific computation
NASA Technical Reports Server (NTRS)
Pratt, T. W.
1985-01-01
The parallel implementation of scientific computing environment (PISCES) is a project to provide high-level programming environments for parallel MIMD computers. Pisces 1, the first of these environments, is a FORTRAN 77 based environment which runs under the UNIX operating system. The Pisces 1 user programs in Pisces FORTRAN, an extension of FORTRAN 77 for parallel processing. The major emphasis in the Pisces 1 design is in providing a carefully specified virtual machine that defines the run-time environment within which Pisces FORTRAN programs are executed. Each implementation then provides the same virtual machine, regardless of differences in the underlying architecture. The design is intended to be portable to a variety of architectures. Currently Pisces 1 is implemented on a network of Apollo workstations and on a DEC VAX uniprocessor via simulation of the task level parallelism. An implementation for the Flexible Computing Corp. FLEX/32 is under construction. An introduction to the Pisces 1 virtual computer and the FORTRAN 77 extensions is presented. An example of an algorithm for the iterative solution of a system of equations is given. The most notable features of the design are the provision for several granularities of parallelism in programs and the provision of a window mechanism for distributed access to large arrays of data.
Defense AT and L Magazine. Vol. 42, no. 6, November-December 2013
2013-11-01
Blackberries , e-mail, conference calls, flextime and flex place. The project manager no longer can always schedule face-to-face weekly team meetings...alive and well! In an age of cellphones, Blackberries , e-mail, conference calls, flextime and flex place, the PM no longer has the luxury of always... Blackberries (or other “smart” devices) Have you ever been in a crowded room when a cell phone chimes? It’s like being at the OK Corral where everyone in the
Horizon Scan of Emerging Technologies and Trends for ADF Combat Service Support 2016
2016-12-01
Autonomous Robot (SMART) for stitching [315], Flex Robotic System and Flex arm for operating through non-linear winding paths (like the throat) [314...knows-about-customers-habits.html?referer=&_r=0. 15. Singer, P. W. (2009) Wired for War. The Robotics Revolution and Conflict in the 21st Century...spotlight/spotid=40493.php. 61. Chandler, D. L. (2015) Tiny wires could provide a big energy boost. MIT via Nanowerk News, 7 July 2015 [Last accessed 16
NASA Astrophysics Data System (ADS)
Rawat, Vaishali; Nadkarni, Vihang; Kale, S. N.
2017-01-01
A stand-alone device working on the electrical metamaterial concept, operating at 2.47 GHz (ISM band), using merely 10 μL sample is proposed to detect petrol/ethanol ratio in given hybrid fuel. Systematic shifts in the transmission frequency as well as magnitude are observed, up to a maximum of 160 MHz and 12 dBm with the hybrid fuels. The sensing was fast with an instantaneous recovery, promising an accurate and sensitive device of detection of flex fuel.
Optical fiber pressure and acceleration sensor fabricated on a fiber endface
Zhu, Yizheng; Wang, Xingwei; Xu, Juncheng; Wang, Anbo
2006-05-30
A fiber optic sensor has a hollow tube bonded to the endface of an optical fiber, and a diaphragm bonded to the hollow tube. The fiber endface and diaphragm comprise an etalon cavity. The length of the etalon cavity changes when applied pressure or acceleration flexes the diaphragm. The entire structure can be made of fused silica. The fiber, tube, and diaphragm can be bonded with a fusion splice. The present sensor is particularly well suited for measuring pressure or acceleration in high temperature, high pressure and corrosive environments (e.g., oil well downholes and jet engines). The present sensors are also suitable for use in biological and medical applications.
NASA Astrophysics Data System (ADS)
Hazeli, K.; Kingstedt, O. T.
2017-05-01
It is critical to investigate the performance of electronic systems and their components under the environments experienced during proposed missions to improve spacecraft and robotic vehicle functionality and performance in extreme environments.
Eukaryotic Organisms in Extreme Acidic Environments, the Río Tinto Case
NASA Astrophysics Data System (ADS)
Angeles Aguilera, Angeles
2013-07-01
A major issue in microbial ecology is to identify the limits of life for growth and survival, and to understand the molecular mechanisms that define these limits. Thus, interest in the biodiversity and ecology of extreme environments has grown in recent years for several reasons. Some are basic and revolve around the idea that extreme environments are believed to reflect early Earth conditions. Others are related to the biotechnological potential of extremophiles. In this regard, the study of extremely acidic environments has become increasingly important since environmental acidity is often caused by microbial activity. Highly acidic environments are relatively scarce worldwide and are generally associated with volcanic activity or mining operations. For most acidic environments, low pH facilitates metal solubility, and therefore acidic waters tend to have high concentrations of heavy metals. However, highly acidic environments are usually inhabited by acidophilic and acidotolerant eukaryotic microorganisms such as algae, amoebas, ciliates, heliozoan and rotifers, not to mention filamentous fungi and yeasts. Here, we review the general trends concerning the diversity and ecophysiology of eukaryotic acidophilic microorganims, as well as summarize our latest results on this topic in one of the largest extreme acidic rivers, Río Tinto (SW, Spain).
Extreme Programming in a Research Environment
NASA Technical Reports Server (NTRS)
Wood, William A.; Kleb, William L.
2002-01-01
This article explores the applicability of Extreme Programming in a scientific research context. The cultural environment at a government research center differs from the customer-centric business view. The chief theoretical difficulty lies in defining the customer to developer relationship. Specifically, can Extreme Programming be utilized when the developer and customer are the same person? Eight of Extreme Programming's 12 practices are perceived to be incompatible with the existing research culture. Further, six of the nine 'environments that I know don't do well with XP' apply. A pilot project explores the use of Extreme Programming in scientific research. The applicability issues are addressed and it is concluded that Extreme Programming can function successfully in situations for which it appears to be ill-suited. A strong discipline for mentally separating the customer and developer roles is found to be key for applying Extreme Programming in a field that lacks a clear distinction between the customer and the developer.
Insertion sequences enrichment in extreme Red sea brine pool vent.
Elbehery, Ali H A; Aziz, Ramy K; Siam, Rania
2017-03-01
Mobile genetic elements are major agents of genome diversification and evolution. Limited studies addressed their characteristics, including abundance, and role in extreme habitats. One of the rare natural habitats exposed to multiple-extreme conditions, including high temperature, salinity and concentration of heavy metals, are the Red Sea brine pools. We assessed the abundance and distribution of different mobile genetic elements in four Red Sea brine pools including the world's largest known multiple-extreme deep-sea environment, the Red Sea Atlantis II Deep. We report a gradient in the abundance of mobile genetic elements, dramatically increasing in the harshest environment of the pool. Additionally, we identified a strong association between the abundance of insertion sequences and extreme conditions, being highest in the harshest and deepest layer of the Red Sea Atlantis II Deep. Our comparative analyses of mobile genetic elements in secluded, extreme and relatively non-extreme environments, suggest that insertion sequences predominantly contribute to polyextremophiles genome plasticity.
Comparison of cyclic fatigue resistance of novel nickel-titanium rotary instruments.
Capar, Ismail Davut; Ertas, Huseyin; Arslan, Hakan
2015-04-01
New files (ProTaper Next/HyFlex/OneShape) are made from novel nickel-titanium (NiTi) alloys/treatments. The purpose of this study was to compare the cyclic fatigue resistance of these new instruments with that of Revo-S instruments. Four groups of 20 NiTi endodontic instruments were tested in steel canals with a 3 mm radius and a 60° angle of curvature. The cyclic fatigue of the following NiTi instruments with a tip size 25 and 0.06 taper that were manufactured with different alloys was tested: ProTaper Next X2 (M-Wire), OneShape (conventional NiTi), Revo-S Shaping Universal (conventional NiTi) and HyFlex 25/0.6 (controlled memory NiTi wire). A one-way anova and post-hoc Tukey's test (α = 0.05) revealed that the HyFlex files had the highest fatigue resistance and the Revo-S had the least fatigue resistance among the groups (P < 0.001). © 2014 Australian Society of Endodontology.
Mechanical flexible joint design document
NASA Technical Reports Server (NTRS)
Daily, Vic
1993-01-01
The purpose of this report is to document the status of the Mechanical Flexible Joint (MFJ) Design Subtask with the intent of halting work on the design. Recommendations for future work is included in the case that the task is to be resumed. The MFJ is designed to eliminate two failure points from the current flex joint configuration, the inner 'tripod configuration' and the outer containment jacket. The MFJ will also be designed to flex 13.5 degrees and have three degrees of freedom. By having three degrees of freedom, the MFJ will allow the Low Pressure Fuel Duct to twist and remove the necessity to angulate the full 11 degrees currently required. The current flex joints are very labor intensive and very costly and a simple alternative is being sought. The MFJ is designed with a greater angular displacement, with three degrees of freedom, to reside in the same overall envelope, to meet weight constraints of the current bellows, to be compatible with cryogenic fuel and oxidizers, and also to be man-rated.
Schirrmeister, Jörg F; Strohl, Christian; Altenburger, Markus J; Wrbas, Karl-Thomas; Hellwig, Elmar
2006-06-01
To compare the shaping ability and safety of engine-driven FlexMaster, GT Rotary, ProFile, ProTaper, and RaCe rotary instrumentation and Hedström hand instrumentation in simulated root canals. One hundred fifty simulated colored root canals with a curvature of 20 degrees and a radius of 10 mm were randomly distributed among 6 groups of 25 specimens each. After preparation to apical size 30 the area of remaining color on the canal wall indicating unprepared areas was measured in mm2 using image analyzer software. Specimens treated with RaCe left least areas of remaining color compared to all other groups (P < .001), followed by ProTaper. Preparation with ProFile left behind the highest amount of unprepared areas. The ProFile group revealed significantly more remaining color than ProTaper, GT Rotary, and FlexMaster (P < .05). Four FlexMaster files separated. RaCe rotary files were safe and more effective compared to the other instruments.
Multistrand superconductor cable
Borden, Albert R.
1985-01-01
Improved multistrand Rutherford-type superconductor cable is produced by using strands which are preformed, prior to being wound into the cable, so that each strand has a variable cross section, with successive portions having a substantially round cross section, a transitional oval cross section, a rectangular cross section, a transitional oval cross section, a round cross section and so forth, in repetitive cycles along the length of the strand. The cable is wound and flattened so that the portions of rectangular cross section extend across the two flat sides of the cable at the strand angle. The portions of round cross section are bent at the edges of the flattened cable, so as to extend between the two flat sides. The rectangular portions of the strands slide easily over one another, so as to facilitate flexing and bending of the cable, while also minimizing the possibility of causing damage to the strands by such flexing or bending. Moreover, the improved cable substantially maintains its compactness and cross-sectional shape when the cable is flexed or bent.
A flex-compressive-mode piezoelectric transducer for mechanical vibration/strain energy harvesting.
Li, Xiaotian; Guo, Mingsen; Dong, Shuxiang
2011-04-01
A piezoelectric transducer for harvesting energy from ambient mechanical vibrations/strains under pressure condition was developed. The proposed transducer was made of two ring-type piezoelectric stacks, one pair of bow-shaped elastic plates, and one shaft that pre-compresses them. This transducer works in flex-compressive (F-C) mode, which is different from a conventional flex-tensional (F-T) one, to transfer a transversely applied force F into an amplified longitudinal force N pressing against the two piezo-stacks via the two bowshaped elastic plates, generating a large electric voltage output via piezoelectric effect. Our experimental results show that without an electric load, an F-C mode piezo-transducer could generate a maximum electric voltage output of up to 110 Vpp, and with an electric load of 40 κΩ, it a maximum power output of 14.6 mW under an acceleration excitation of 1 g peak-peak at the resonance frequency of 87 Hz. © 2011 IEEE
Nearshore wave-induced cyclical flexing of sea cliffs
Adams, P.N.; Storlazzi, C.D.; Anderson, R. Scott
2005-01-01
[1] Evolution of a tectonically active coast is driven by geomorphically destructive energy supplied by ocean waves. Wave energy is episodic and concentrated; sea cliffs are battered by the geomorphic wrecking ball every 4-25 s. We measure the response of sea cliffs to wave assault by sensing the ground motion using near-coastal seismometers. Sea cliffs respond to waves in two distinct styles. High-frequency motion (20 Hz) reflects the natural frequency of the sea cliff as it rings in response to direct wave impact. Low-frequency motion in the 0.1-0.05 Hz (10-20 s) band consistently agrees with the dominant nearshore wave period. Integrating microseismic velocities suggests 50 ??m and 10 ??m displacements in horizontal and vertical directions, respectively. Displacement ellipsoids exhibit simultaneous downward and seaward sea cliff motion with each wave. Video footage corroborates the downward sea cliff flex in response to the imposed water load on the wave cut platform. Gradients in displacement amplitudes documented using multiple seismometers suggest longitudinal and shear strain of the flexing sea cliff on the order of 0.5-4 ?? strains during each wave loading cycle. As this sea cliff flexure occurs approximately 3 million times annually, it has the potential to fatigue the rock through cyclical loading. Local sea cliff retreat rates of 10 cm/yr imply that a given parcel of rock is flexed through roughly 109 cycles of increasing amplitude before exposure to direct wave attack at the cliff face. Copyright 2005 by the American Geophysical Union.
Adams, William P; Baxter, Richard; Glicksman, Caroline; Mast, Bruce A; Tantillo, Michael; Van Natta, Bruce W
2018-04-06
Mastopexy and reduction mammaplasty are often limited by the patient's poor native soft tissue quality, resulting in ptosis recurrence and loss of rejuvenated surgical results. Surgical scaffolds and acellular dermal matrices are used in these procedures to provide physical and mechanical stabilization of weakened or compromised tissue. GalaFLEX scaffold, made from poly-4-hydroxybutyrate (P4HB), is a next-generation product for soft tissue reinforcement that resorbs gradually while aiding tissue regeneration to achieve excellent outcomes. To assess the clinical performance of GalaFLEX scaffold in soft tissue reinforcement during elective mastopexy and reduction mammaplasty. This multicenter, single-arm, observational study assessed product performance and outcomes of GalaFLEX scaffold when used in breast surgery. Outcomes included ptosis correction and maintenance, associated adverse events, patient and surgeon satisfaction, and mammographic and ultrasound imaging evaluation. At 6 centers in the US, 62 of 69 enrolled patients were treated. Of this population, 89.7% had successful ptosis correction and maintenance at 1 year, with high patient and surgeon satisfaction for breast shape, droop/sag of the breast, and maintenance of results at 1 year. There were 5 adverse events deemed related to the device (8.0%), including nerve pain, breast swelling, ptosis, and 2 instances of asymmetry. GalaFLEX scaffold safely and successfully supports and elevates breast tissue in mastopexy and reduction mammaplasty, with maintained support at 1 year. Surgeon and patient satisfaction were high. No mammogram or ultrasound interference was detected.
Low-Cost Methodology for Skin Strain Measurement of a Flexed Biological Limb.
Lin, Bevin; Moerman, Kevin M; McMahan, Connor G; Pasch, Kenneth A; Herr, Hugh M
2017-12-01
The purpose of this manuscript is to compute skin strain data from a flexed biological limb, using portable, inexpensive, and easily available resources. We apply and evaluate this approach on a person with bilateral transtibial amputations, imaging left and right residual limbs in extended and flexed knee postures. We map 3-D deformations to a flexed biological limb using freeware and a simple point-and-shoot camera. Mean principal strain, maximum shear strain, as well as lines of maximum, minimum, and nonextension are computed from 3-D digital models to inform directional mappings of the strain field for an unloaded residual limb. Peak tensile strains are ∼0.3 on the anterior surface of the knee in the proximal region of the patella, whereas peak compressive strains are ∼ -0.5 on the posterior surface of the knee. Peak maximum shear strains are ∼0.3 on the posterior surface of the knee. The accuracy and precision of this methodology are assessed for a ground-truth model. The mean point location distance is found to be 0.08 cm, and the overall standard deviation for point location difference vectors is 0.05 cm. This low-cost and mobile methodology may prove critical for applications such as the prosthetic socket interface where whole-limb skin strain data are required from patients in the field outside of traditional, large-scale clinical centers. Such data may inform the design of wearable technologies that directly interface with human skin.
Attachment method for stacked integrated circuit (IC) chips
Bernhardt, A.F.; Malba, V.
1999-08-03
An attachment method for stacked integrated circuit (IC) chips is disclosed. The method involves connecting stacked chips, such as DRAM memory chips, to each other and/or to a circuit board. Pads on the individual chips are rerouted to form pads on the side of the chip, after which the chips are stacked on top of each other whereby desired interconnections to other chips or a circuit board can be accomplished via the side-located pads. The pads on the side of a chip are connected to metal lines on a flexible plastic tape (flex) by anisotropically conductive adhesive (ACA). Metal lines on the flex are likewise connected to other pads on chips and/or to pads on a circuit board. In the case of a stack of DRAM chips, pads to corresponding address lines on the various chips may be connected to the same metal line on the flex to form an address bus. This method has the advantage of reducing the number of connections required to be made to the circuit board due to bussing; the flex can accommodate dimensional variation in the alignment of chips in the stack; bonding of the ACA is accomplished at low temperature and is otherwise simpler and less expensive than solder bonding; chips can be bonded to the ACA all at once if the sides of the chips are substantially coplanar, as in the case for stacks of identical chips, such as DRAM. 12 figs.
An aerodynamic study on flexed blades for VAWT applications
NASA Astrophysics Data System (ADS)
Micallef, Daniel; Farrugia, Russell; Sant, Tonio; Mollicone, Pierluigi
2014-12-01
There is renewed interest in aerodynamics research of VAWT rotors. Lift type, Darrieus designs sometimes use flexed blades to have an 'egg-beater shape' with an optimum Troposkien geometry to minimize the structural stress on the blades. While straight bladed VAWTs have been investigated in depth through both measurements and numerical modelling, the aerodynamics of flexed blades has not been researched with the same level of detail. Two major effects may have a substantial impact on blade performance. First, flexing at the equator causes relatively strong trailing vorticity to be released. Secondly, the blade performance at each station along the blade is influenced by self-induced velocities due to bound vorticity. The latter is not present in a straight bladed configuration. The aim of this research is to investigate these effects in relation to an innovative 4kW wind turbine concept being developed in collaboration with industry known as a self-adjusting VAWT (or SATVAWT). The approach used in this study is based on experimental and numerical work. A lifting line free-wake vortex model was developed. Wind tunnel power and hot-wire velocity measurements were performed on a scaled down, 60cm high, three bladed model in a closed wind tunnel. Results show a substantial axial wake induction at the equator resulting in a lower power generation at this position. This induction increases with increasing degree of flexure. The self-induced velocities caused by blade bound vorticity at a particular station was found to be relatively small.
Torsion and bending properties of shape memory and superelastic nickel-titanium rotary instruments.
Ninan, Elizabeth; Berzins, David W
2013-01-01
Recently introduced into the market are shape memory nickel-titanium (NiTi) rotary files. The objective of this study was to investigate the torsion and bending properties of shape memory files (CM Wire, HyFlex CM, and Phoenix Flex) and compare them with conventional (ProFile ISO and K3) and M-Wire (GT Series X and ProFile Vortex) NiTi files. Sizes 20, 30, and 40 (n = 12/size/taper) of 0.02 taper CM Wire, Phoenix Flex, K3, and ProFile ISO and 0.04 taper HyFlex CM, ProFile ISO, GT Series X, and Vortex were tested in torsion and bending per ISO 3630-1 guidelines by using a torsiometer. All data were statistically analyzed by analysis of variance and the Tukey-Kramer test (P = .05) to determine any significant differences between the files. Significant interactions were present among factors of size and file. Variability in maximum torque values was noted among the shape memory files brands, sometimes exhibiting the greatest or least torque depending on brand, size, and taper. In general, the shape memory files showed a high angle of rotation before fracture but were not statistically different from some of the other files. However, the shape memory files were more flexible, as evidenced by significantly lower bending moments (P < .008). Shape memory files show greater flexibility compared with several other NiTi rotary file brands. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Ensemble-based evaluation for protein structure models.
Jamroz, Michal; Kolinski, Andrzej; Kihara, Daisuke
2016-06-15
Comparing protein tertiary structures is a fundamental procedure in structural biology and protein bioinformatics. Structure comparison is important particularly for evaluating computational protein structure models. Most of the model structure evaluation methods perform rigid body superimposition of a structure model to its crystal structure and measure the difference of the corresponding residue or atom positions between them. However, these methods neglect intrinsic flexibility of proteins by treating the native structure as a rigid molecule. Because different parts of proteins have different levels of flexibility, for example, exposed loop regions are usually more flexible than the core region of a protein structure, disagreement of a model to the native needs to be evaluated differently depending on the flexibility of residues in a protein. We propose a score named FlexScore for comparing protein structures that consider flexibility of each residue in the native state of proteins. Flexibility information may be extracted from experiments such as NMR or molecular dynamics simulation. FlexScore considers an ensemble of conformations of a protein described as a multivariate Gaussian distribution of atomic displacements and compares a query computational model with the ensemble. We compare FlexScore with other commonly used structure similarity scores over various examples. FlexScore agrees with experts' intuitive assessment of computational models and provides information of practical usefulness of models. https://bitbucket.org/mjamroz/flexscore dkihara@purdue.edu Supplementary data are available at Bioinformatics online. © The Author 2016. Published by Oxford University Press.
Ensemble-based evaluation for protein structure models
Jamroz, Michal; Kolinski, Andrzej; Kihara, Daisuke
2016-01-01
Motivation: Comparing protein tertiary structures is a fundamental procedure in structural biology and protein bioinformatics. Structure comparison is important particularly for evaluating computational protein structure models. Most of the model structure evaluation methods perform rigid body superimposition of a structure model to its crystal structure and measure the difference of the corresponding residue or atom positions between them. However, these methods neglect intrinsic flexibility of proteins by treating the native structure as a rigid molecule. Because different parts of proteins have different levels of flexibility, for example, exposed loop regions are usually more flexible than the core region of a protein structure, disagreement of a model to the native needs to be evaluated differently depending on the flexibility of residues in a protein. Results: We propose a score named FlexScore for comparing protein structures that consider flexibility of each residue in the native state of proteins. Flexibility information may be extracted from experiments such as NMR or molecular dynamics simulation. FlexScore considers an ensemble of conformations of a protein described as a multivariate Gaussian distribution of atomic displacements and compares a query computational model with the ensemble. We compare FlexScore with other commonly used structure similarity scores over various examples. FlexScore agrees with experts’ intuitive assessment of computational models and provides information of practical usefulness of models. Availability and implementation: https://bitbucket.org/mjamroz/flexscore Contact: dkihara@purdue.edu Supplementary information: Supplementary data are available at Bioinformatics online. PMID:27307633
Extreme Terrestrial Environments: Life in Thermal Stress and Hypoxia. A Narrative Review.
Burtscher, Martin; Gatterer, Hannes; Burtscher, Johannes; Mairbäurl, Heimo
2018-01-01
Living, working and exercising in extreme terrestrial environments are challenging tasks even for healthy humans of the modern new age. The issue is not just survival in remote environments but rather the achievement of optimal performance in everyday life, occupation, and sports. Various adaptive biological processes can take place to cope with the specific stressors of extreme terrestrial environments like cold, heat, and hypoxia (high altitude). This review provides an overview of the physiological and morphological aspects of adaptive responses in these environmental stressors at the level of organs, tissues, and cells. Furthermore, adjustments existing in native people living in such extreme conditions on the earth as well as acute adaptive responses in newcomers are discussed. These insights into general adaptability of humans are complemented by outcomes of specific acclimatization/acclimation studies adding important information how to cope appropriately with extreme environmental temperatures and hypoxia.
Extreme Terrestrial Environments: Life in Thermal Stress and Hypoxia. A Narrative Review
Burtscher, Martin; Gatterer, Hannes; Burtscher, Johannes; Mairbäurl, Heimo
2018-01-01
Living, working and exercising in extreme terrestrial environments are challenging tasks even for healthy humans of the modern new age. The issue is not just survival in remote environments but rather the achievement of optimal performance in everyday life, occupation, and sports. Various adaptive biological processes can take place to cope with the specific stressors of extreme terrestrial environments like cold, heat, and hypoxia (high altitude). This review provides an overview of the physiological and morphological aspects of adaptive responses in these environmental stressors at the level of organs, tissues, and cells. Furthermore, adjustments existing in native people living in such extreme conditions on the earth as well as acute adaptive responses in newcomers are discussed. These insights into general adaptability of humans are complemented by outcomes of specific acclimatization/acclimation studies adding important information how to cope appropriately with extreme environmental temperatures and hypoxia. PMID:29867589
Providing Middle School Students With Science Research Experiences Through Community Partnerships
NASA Astrophysics Data System (ADS)
Rodriguez, D.
2007-12-01
Science research courses have been around for years at the university and high school level. As inquiry based learning has become more and more a part of the science teacher's vocabulary, many of these courses have adopted an inquiry model for studying science. Learners of all ages benefit from learning through the natural process of inquiry. I participated in the CIRES Earthworks program for science teachers (Colorado University) in the summer of 2007 and experienced, first hand, the value of inquiry learning. With the support and vision of my school administration, and with the support and commitment of community partners, I have developed a Middle School Science Research Program that is transforming how science is taught to students in my community. Swift Creek Middle School is located in Tallahassee, Florida. There are approximately 1000 students in this suburban public school. Students at Swift Creek are required to take one science class each year through 8th grade. As more emphasis is placed on learning a large number of scientific facts and information, in order to prepare students for yearly, standardized tests, there is a concern that less emphasis may be placed on the process and nature of science. The program I developed draws from the inquiry model followed at the CIRES Earthworks program, utilizes valuable community partnerships, and plays an important role in meeting that need. There are three major components to this Middle School Research Program, and the Center for Integrated Research and Learning (CIRL) at the National High Magnetic Field Lab (NHMFL) at Florida State University is playing an important role in all three. First, each student will develop their own research question and design experiments to answer the question. Scientists from the NHMFL are serving as mentors, or "buddy scientists," to my students as they work through the process of inquiry. Scientists from the CIRES - Earthworks program, Florida State University, and other institutions are also volunteering to be mentors. Second, each student will participate in the GLOBE-FLEXE pilot program that involves comparing environmental conditions of local environments to those of extreme environments, like hydrothermal vents in the deep sea. This real-world science program is being coordinated through the FLEXE Project Office at Penn State University, and the GLOBE Program Office in Boulder, Co. We will spend 18 class periods collecting local weather data and analyzing meteorological data from around the world, writing scientific reports, and peer reviewing other students reports. The NHMFL is a sponsor of the Communtiy Classroom Consortium in Tallahassee that is has funded a grant for equipment needed to conduct the data collection portion of this process. Finally, the students will share their research with other students, parents, teachers, and scientists at a school science fair in the fall, and a scientific poster session in the spring. The NHMFL will be supplying judges for the two sessions. They will also be offering the use of their facilities at the laboratory in the spring. Scientists from the lab will mingle with the students, discuss their research, and critique and encourage the young scientists at the first annual Middle School Research Symposium in May, 2008.
NASA Astrophysics Data System (ADS)
Magnusson, M. L.; Pope, M. H.
1998-08-01
Many vibrational environments also subject the worker to awkward, asymmetric and prolonged postures. This paper reviews the epidemiological, biomechanical and physiological factors involved in working postures which could lead to musculoskeletal problems. Too little or too much sitting leads to low back pain. Sedentary postures, including driving, also lead to a higher risk of a herniated disc. In sitting the pelvis rotates and higher pressures exist in the disk. A backrest inclined to 110° or more and with a lumbar support will reduce the disk pressure. Jobs involving excessive force application will be more apt to cause muscular and ligamentous damage. However, these excessive demands can occur in whole body vibration environments too. Neck, shoulder and arm problems are usually related to posture but can occur in WBV environments. Knee problems, in the standing worker, may be due to a flexed knee posture in an attempt to attenuate vibrations. Excessive postural demands on the neck, shoulder and arm will lead to higher muscle forces and higher joint forces. Recommendations are given to reduce risk of disability.
Chaput, Ludovic; Martinez-Sanz, Juan; Saettel, Nicolas; Mouawad, Liliane
2016-01-01
In a structure-based virtual screening, the choice of the docking program is essential for the success of a hit identification. Benchmarks are meant to help in guiding this choice, especially when undertaken on a large variety of protein targets. Here, the performance of four popular virtual screening programs, Gold, Glide, Surflex and FlexX, is compared using the Directory of Useful Decoys-Enhanced database (DUD-E), which includes 102 targets with an average of 224 ligands per target and 50 decoys per ligand, generated to avoid biases in the benchmarking. Then, a relationship between these program performances and the properties of the targets or the small molecules was investigated. The comparison was based on two metrics, with three different parameters each. The BEDROC scores with α = 80.5, indicated that, on the overall database, Glide succeeded (score > 0.5) for 30 targets, Gold for 27, FlexX for 14 and Surflex for 11. The performance did not depend on the hydrophobicity nor the openness of the protein cavities, neither on the families to which the proteins belong. However, despite the care in the construction of the DUD-E database, the small differences that remain between the actives and the decoys likely explain the successes of Gold, Surflex and FlexX. Moreover, the similarity between the actives of a target and its crystal structure ligand seems to be at the basis of the good performance of Glide. When all targets with significant biases are removed from the benchmarking, a subset of 47 targets remains, for which Glide succeeded for only 5 targets, Gold for 4 and FlexX and Surflex for 2. The performance dramatic drop of all four programs when the biases are removed shows that we should beware of virtual screening benchmarks, because good performances may be due to wrong reasons. Therefore, benchmarking would hardly provide guidelines for virtual screening experiments, despite the tendency that is maintained, i.e., Glide and Gold display better performance than FlexX and Surflex. We recommend to always use several programs and combine their results. Graphical AbstractSummary of the results obtained by virtual screening with the four programs, Glide, Gold, Surflex and FlexX, on the 102 targets of the DUD-E database. The percentage of targets with successful results, i.e., with BDEROC(α = 80.5) > 0.5, when the entire database is considered are in Blue, and when targets with biased chemical libraries are removed are in Red.
New insights on equid locomotor evolution from the lumbar region of fossil horses
Jones, Katrina Elizabeth
2016-01-01
The specialization of equid limbs for cursoriality is a classic case of adaptive evolution, but the role of the axial skeleton in this famous transition is not well understood. Extant horses are extremely fast and efficient runners, which use a stiff-backed gallop with reduced bending of the lumbar region relative to other mammals. This study tests the hypothesis that stiff-backed running in horses evolved in response to evolutionary increases in body size by examining lumbar joint shape from a broad sample of fossil equids in a phylogenetic context. Lumbar joint shape scaling suggests that stability of the lumbar region does correlate with size through equid evolution. However, scaling effects were dampened in the posterior lumbar region, near the sacrum, which suggests strong selection for sagittal mobility in association with locomotor–respiratory coupling near the lumbosacral joint. I hypothesize that small-bodied fossil horses may have used a speed-dependent running gait, switching between stiff-backed and flex-backed galloping as speed increased. PMID:27122554
Paramedics on the job: dynamic trunk motion assessment at the workplace.
Prairie, Jérôme; Corbeil, Philippe
2014-07-01
Many paramedics' work accidents are related to physical aspects of the job, and the most affected body part is the low back. This study documents the trunk motion exposure of paramedics on the job. Nine paramedics were observed over 12 shifts (120 h). Trunk postures were recorded with the computer-assisted CUELA measurement system worn on the back like a knapsack. Average duration of an emergency call was 23.5 min. Sagittal trunk flexion of >40° and twisting rotation of >24° were observed in 21% and 17% of time-sampled postures. Medical care on the scene (44% of total time) involved prolonged flexed and twisted postures (∼ 10s). The highest extreme sagittal trunk flexion (63°) and twisting rotation (40°) were observed during lifting activities, which lasted 2% of the total time. Paramedics adopted trunk motions that may significantly increase the risk of low back disorders during medical care and patient-handling activities. Copyright © 2013. Published by Elsevier Ltd.
NASA Astrophysics Data System (ADS)
Rettberg, P.; Ellis-Evans, C.; Prieur, D.; Loreto, F.; Walter, N.; Le Bris, N.; Elster, J.; Amils, R.; Marteinsson, V.
2008-09-01
Life in Extreme Environments is an emerging area of research in which Europe has considerable expertise but a relatively fragmented research infrastructure. The science of such environments has enormous relevance for our knowledge of the diversity and environmental limits of microbial, plant and animal life and the novel strategies employed for survival and growth. Such studies are essential in understanding how life established on the early Earth and in assessing the possibilities for life on other planetary bodies. These environments are also a rich source of novel exploitable compounds. At the European level, there is a need for better coordination of life in extreme environments research, the FP7-funded CAREX project aims to address this need by developing a clearly identifiable, dynamic and durable community. Establishing this community will encourage greater interdisciplinarity and increasing knowledge of extreme environments. It will provide a target for young career scientists and allow a more focussed dialogue with other science areas, with funding agencies, with industrial groups and with international organisations outside Europe. CAREX will last for three years and with a wide scope covering microbial life, plant adaptation and animal adaptation to various marine, polar, terrestrial extreme environments as well as outer space. CAREX's outputs will include a strategic roadmap for European life in extreme environments research (including enabling technologies), diverse opportunities for knowledge transfer, standardisation of methodologies, encouragement and support for early career scientists and a network of links to relevant organisations. These deliverables together with improved community networking, supported by newsletters, promotional leaflets, a series of science publications and an interactive web portal, will help consolidate the community and its identity. Outcomes will be facilitated through science/technology workshops, diverse forums, field/laboratory protocol intercomparisons, a summer school and individual grants to facilitate knowledge transfer. CAREX has evolved with the key players from the highly successful ESF "Investigating Life in Extreme Environments" initiative. For more information: www.carex-eu.org
Mechanisms of force and power production in unsteady ricochetal brachiation.
Usherwood, James R; Larson, Susan G; Bertram, John E A
2003-04-01
Brachiators travel by swinging beneath handholds, and it is not obvious how these animals manage to accelerate and decelerate in a horizontal direction, especially when moving rapidly. Most previous analyses focused on brachiation in highly constrained laboratory conditions that induced steady-state locomotion. Emerging understanding of brachiation suggests that much of gibbon locomotory behavior and morphology must be considered within the context of the complexities of the natural environment: the forest canopy is three-dimensional, with high variation in handhold availability and properties. The goal of this paper is to quantify the active mechanisms by which gibbons can dynamically control their velocity. Force production and kinematics were analyzed from a white-handed gibbon Hylabates lar during ricochetal brachiation. Both the mechanisms of force production and power input may be inferred for accelerating and decelerating brachiation by combining force data with kinematics. Examples of steady-state, accelerating, and decelerating ricochetal brachiation are highlighted. Gibbons are able to produce net horizontal impulses by releasing early (resulting in a loss of potential energy, but an accelerating horizontal impulse) or delaying release (associated with an increase in potential energy, and a decelerating horizontal impulse). Torque about the shoulder, leg-lifting (or dropping), and elbow flexing (or straightening) are discussed as potential mechanisms for controlling energy within the brachiating system. Of these possibilities, leg-lifting and arm-flexing were observed as mechanisms of adding mechanical energy. Net energy loss, and substantial torques about the shoulder, were not observed. Copyright 2003 Wiley-Liss, Inc.
Maleckis, Kaspars; Deegan, Paul; Poulson, William; Sievers, Cole; Desyatova, Anastasia; MacTaggart, Jason; Kamenskiy, Alexey
2017-11-01
High failure rates of Peripheral Arterial Disease (PAD) stenting appear to be associated with the inability of certain stent designs to accommodate severe biomechanical environment of the femoropopliteal artery (FPA) that bends, twists, and axially compresses during limb flexion. Twelve Nitinol stents (Absolute Pro, Supera, Lifestent, Innova, Zilver, Smart Control, Smart Flex, EverFlex, Viabahn, Tigris, Misago, and Complete SE) were quasi-statically tested under bench-top axial and radial compression, axial tension, bending, and torsional deformations. Stents were compared in terms of force-strain behavior, stiffness, and geometrical shape under each deformation mode. Tigris was the least stiff stent under axial compression (6.6N/m axial stiffness) and bending (0.1N/m) deformations, while Smart Control was the stiffest (575.3N/m and 105.4N/m, respectively). Under radial compression Complete SE was the stiffest (892.8N/m), while Smart Control had the lowest radial stiffness (211.0N/m). Viabahn and Supera had the lowest and highest torsional stiffness (2.2μNm/° and 959.2μNm/°), respectively. None of the 12 PAD stents demonstrated superior characteristics under all deformation modes and many experienced global buckling and diameter pinching. Though it is yet to be determined which of these deformation modes might have greater clinical impact, results of the current analysis may help guide development of new stents with improved mechanical characteristics. Copyright © 2017 Elsevier Ltd. All rights reserved.
Stretchable form of single crystal silicon for high performance electronics on rubber substrates
University of Illinois
2009-04-21
The present invention provides stretchable, and optionally printable, semiconductors and electronic circuits capable of providing good performance when stretched, compressed, flexed or otherwise deformed. Stretchable semiconductors and electronic circuits of the present invention preferred for some applications are flexible, in addition to being stretchable, and thus are capable of significant elongation, flexing, bending or other deformation along one or more axes. Further, stretchable semiconductors and electronic circuits of the present invention may be adapted to a wide range of device configurations to provide fully flexible electronic and optoelectronic devices.
Stretchable form of single crystal silicon for high performance electronics on rubber substrates
Rogers, John A [Champaign, IL; Khang, Dahl-Young [Seoul, KR; Sun, Yugang [Naperville, IL; Menard, Etienne [Durham, NC
2012-06-12
The present invention provides stretchable, and optionally printable, semiconductors and electronic circuits capable of providing good performance when stretched, compressed, flexed or otherwise deformed. Stretchable semiconductors and electronic circuits of the present invention preferred for some applications are flexible, in addition to being stretchable, and thus are capable of significant elongation, flexing, bending or other deformation along one or more axes. Further, stretchable semiconductors and electronic circuits of the present invention may be adapted to a wide range of device configurations to provide fully flexible electronic and optoelectronic devices.
Stretchable form of single crystal silicon for high performance electronics on rubber substrates
Rogers, John A.; Khang, Dahl-Young; Sun, Yugang; Menard, Etienne
2014-06-17
The present invention provides stretchable, and optionally printable, semiconductors and electronic circuits capable of providing good performance when stretched, compressed, flexed or otherwise deformed. Stretchable semiconductors and electronic circuits of the present invention preferred for some applications are flexible, in addition to being stretchable, and thus are capable of significant elongation, flexing, bending or other deformation along one or more axes. Further, stretchable semiconductors and electronic circuits of the present invention may be adapted to a wide range of device configurations to provide fully flexible electronic and optoelectronic devices.
Stretchable form of single crystal silicon for high performance electronics on rubber substrates
Rogers, John A.; Khang, Dahl-Young; Sun, Yugang; Menard, Etienne
2016-12-06
The present invention provides stretchable, and optionally printable, semiconductors and electronic circuits capable of providing good performance when stretched, compressed, flexed or otherwise deformed. Stretchable semiconductors and electronic circuits of the present invention preferred for some applications are flexible, in addition to being stretchable, and thus are capable of significant elongation, flexing, bending or other deformation along one or more axes. Further, stretchable semiconductors and electronic circuits of the present invention may be adapted to a wide range of device configurations to provide fully flexible electronic and optoelectronic devices.
Stretchable form of single crystal silicon for high performance electronics on rubber substrates
Rogers, John A.; Khang, Dahl -Young; Sun, Yugang; Menard, Etienne
2015-08-11
The present invention provides stretchable, and optionally printable, semiconductors and electronic circuits capable of providing good performance when stretched, compressed, flexed or otherwise deformed. Stretchable semiconductors and electronic circuits of the present invention preferred for some applications are flexible, in addition to being stretchable, and thus are capable of significant elongation, flexing, bending or other deformation along one or more axes. Further, stretchable semiconductors and electronic circuits of the present invention may be adapted to a wide range of device configurations to provide fully flexible electronic and optoelectronic devices.
Evaluation of Ares-I Control System Robustness to Uncertain Aerodynamics and Flex Dynamics
NASA Technical Reports Server (NTRS)
Jang, Jiann-Woei; VanTassel, Chris; Bedrossian, Nazareth; Hall, Charles; Spanos, Pol
2008-01-01
This paper discusses the application of robust control theory to evaluate robustness of the Ares-I control systems. Three techniques for estimating upper and lower bounds of uncertain parameters which yield stable closed-loop response are used here: (1) Monte Carlo analysis, (2) mu analysis, and (3) characteristic frequency response analysis. All three methods are used to evaluate stability envelopes of the Ares-I control systems with uncertain aerodynamics and flex dynamics. The results show that characteristic frequency response analysis is the most effective of these methods for assessing robustness.
Influences of trunk flexion on mechanical energy flow in the lower extremities during gait.
Takeda, Takuya; Anan, Masaya; Takahashi, Makoto; Ogata, Yuta; Tanimoto, Kenji; Shinkoda, Koichi
2016-05-01
[Purpose] The time-series waveforms of mechanical energy generation, absorption, and transfer through the joints indicate how movements are produced and controlled. Previous studies have used these waveforms to evaluate and describe the efficiency of human movements. The purpose of this study was to examine the influence of trunk flexion on mechanical energy flow in the lower extremities during gait. [Subjects and Methods] The subjects were 8 healthy young males (mean age, 21.8 ± 1.3 years, mean height, 170.5 ± 6.8 cm, and mean weight, 60.2 ± 6.8 kg). Subjects walked at a self-selected gait speed under 2 conditions: normal gait (condition N), and gait with trunk flexion formed with a brace to simulate spinal curvature (condition TF). The data collected from initial contact to the mid-stance of gait was analyzed. [Results] There were no significant differences between the 2 conditions in the mechanical energy flow in the knee joint and negative mechanical work in the knee joint. However, the positive mechanical work of the knee joint under condition TF was significantly less than that under condition N. [Conclusion] Trunk flexion led to knee flexion in a standing posture. Thus, a strategy of moving of center of mass upward by knee extension using less mechanical energy was selected during gait in the trunk flexed posture.
Code of Federal Regulations, 2010 CFR
2010-07-01
... EMERGENCY PLANNING AND NOTIFICATION Emergency Planning Who Must Comply § 355.12 What quantities of extremely... 40 Protection of Environment 27 2010-07-01 2010-07-01 false What quantities of extremely hazardous substances trigger emergency planning requirements? 355.12 Section 355.12 Protection of Environment...
NASA Technical Reports Server (NTRS)
Weddendorf, Bruce C. (Inventor)
1994-01-01
An artificial, manually positionable elbow joint for use in an upper extremity, above-elbow, prosthetic is described. The prosthesis provides a locking feature that is easily controlled by the wearer. The instant elbow joint is very strong and durable enough to withstand the repeated heavy loadings encountered by a wearer who works in an industrial, construction, farming, or similar environment. The elbow joint of the present invention comprises a turntable, a frame, a forearm, and a locking assembly. The frame generally includes a housing for the locking assembly and two protruding ears. The forearm includes an elongated beam having a cup-shaped cylindrical member at one end and a locking wheel having a plurality of holes along a circular arc on its other end with a central bore for pivotal attachment to the protruding ears of the frame. The locking assembly includes a collar having a central opening with a plurality of internal grooves, a plurality of internal cam members each having a chamfered surface at one end and a V-shaped slot at its other end; an elongated locking pin having a crown wheel with cam surfaces and locking lugs secured thereto; two coiled compression springs; and a flexible filament attached to one end of the elongated locking pin and extending from the locking assembly for extending and retracting the locking pin into the holes in the locking wheel to permit selective adjustment of the forearm relative to the frame. In use, the turntable is affixed to the upper arm part of the prosthetic in the conventional manner, and the cup-shaped cylindrical member on one end of the forearm is affixed to the forearm piece of the prosthetic in the conventional manner. The elbow joint is easily adjusted and locked between maximum flex and extended positions.
Tsukahara, Yuka; Iwamoto, Jun; Iwashita, Kosui; Shinjo, Takuma; Azuma, Koichiro; Matsumoto, Hideo
2016-01-01
Background Whole-body vibration (WBV) exercise is widely used for training and rehabilitation. However, the optimal posture for training both the upper and lower extremities simultaneously remains to be established. Objectives The objective of this study was to search for an effective posture to conduct vibration from the lower to the upper extremities while performing WBV exercises without any adverse effects. Methods Twelve healthy volunteers (age: 22–34 years) were enrolled in the study. To measure the magnitude of vibration, four accelerometers were attached to the upper arm, back, thigh, and calf of each subject. Vibrations were produced using a WBV platform (Galileo 900) with an amplitude of 4 mm at two frequencies, 15 and 30 Hz. The following three postures were examined: posture A, standing posture with the knees flexed at 30°; posture B, crouching position with no direct contact between the knees and elbows; and posture C, crouching position with direct contact between the knees and elbows. The ratio of the magnitude of vibration at the thigh, back, and upper arm relative to that at the calf was used as an index of vibration conduction. Results Posture B was associated with a greater magnitude of vibration to the calf than posture A at 15 Hz, and postures B and C were associated with greater magnitudes of vibration than posture A at 30 Hz. Posture C was associated with a vibration conduction to the upper arm that was 4.62 times and 8.26 times greater than that for posture A at 15 and 30 Hz, respectively. Conclusion This study revealed that a crouching position on a WBV platform with direct contact between the knees and elbows was effective for conducting vibration from the lower to the upper extremities. PMID:26793008
NASA Technical Reports Server (NTRS)
Kolawa, Elizabeth; Chen, Yuan; Mojarradi, Mohammad M.; Weber, Carissa Tudryn; Hunter, Don J.
2013-01-01
This paper describes the technology development and infusion of a motor drive electronics assembly for Mars Curiosity Rover under space extreme environments. The technology evaluation and qualification as well as space qualification of the assembly are detailed and summarized. Because of the uncertainty of the technologies operating under the extreme space environments and that a high level reliability was required for this assembly application, both component and assembly board level qualifications were performed.
Cutting efficiency of conventional and martensitic nickel-titanium instruments for coronal flaring.
Morgental, Renata Dornelles; Vier-Pelisser, Fabiana Vieira; Kopper, Patrícia Maria Poli; de Figueiredo, José Antonio Poli; Peters, Ove A
2013-12-01
This study aimed at evaluating the influence of rotational speed and number of uses on the cutting efficiency of 4 nickel-titanium coronal flaring instruments against 2 substrates, bovine dentin and acrylic blocks. BioRaCe BR0, HyFlex CM1, ProFile OS#2, and ProTaper Sx were used in simulated lateral action against both substrates at 250 and 500 rpm up to 5 times, producing 5 notches in each block. Notch areas and lengths were measured under a stereomicroscope, and data were compared by using parametric tests (α = 0.05). Against both substrates, HyFlex CM1 and ProFile OS#2 were the most and the least cutting efficient instruments, respectively (P < .05). Against acrylic, area and length values at 500 rpm were significantly higher than those at 250 rpm for all brands. Against dentin, significant differences were detected between 250 and 500 rpm for HyFlex CM1 and ProTaper Sx (area) and for BioRace BR0, HyFlex CM1, and ProTaper Sx (length). Regarding cutting efficiency loss, area and length for notches 1 and 2 (first notches) and 4 and 5 (last notches) were similar against acrylic. Against dentin, length values for notches 1 and 2 were significantly higher than those for notches 4 and 5 in ProFile OS#2 and ProTaper Sx. A strong correlation was detected between the overall results obtained on acrylic and dentin for area and length (P < .0001), although further analysis showed that data against acrylic were a poor predictor of data against dentin after repeated use. HyFlex CM1 was the most cutting efficient instrument in lateral action. An increase in rotational speed improved the cutting efficiency. Results against acrylic showed a high correlation to data against dentin, but acrylic may not be a proper substrate when the intention is to assess cutting efficiency loss with repeated use. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
The flex track: flexible partitioning between low- and high-acuity areas of an emergency department.
Laker, Lauren F; Froehle, Craig M; Lindsell, Christopher J; Ward, Michael J
2014-12-01
Emergency departments (EDs) with both low- and high-acuity treatment areas often have fixed allocation of resources, regardless of demand. We demonstrate the utility of discrete-event simulation to evaluate flexible partitioning between low- and high-acuity ED areas to identify the best operational strategy for subsequent implementation. A discrete-event simulation was used to model patient flow through a 50-bed, urban, teaching ED that handles 85,000 patient visits annually. The ED has historically allocated 10 beds to a fast track for low-acuity patients. We estimated the effect of a flex track policy, which involved switching up to 5 of these fast track beds to serving both low- and high-acuity patients, on patient waiting times. When the high-acuity beds were not at capacity, low-acuity patients were given priority access to flexible beds. Otherwise, high-acuity patients were given priority access to flexible beds. Wait times were estimated for patients by disposition and Emergency Severity Index score. A flex track policy using 3 flexible beds produced the lowest mean patient waiting time of 30.9 minutes (95% confidence interval [CI] 30.6 to 31.2 minutes). The typical fast track approach of rigidly separating high- and low-acuity beds produced a mean patient wait time of 40.6 minutes (95% CI 40.2 to 50.0 minutes), 31% higher than that of the 3-bed flex track. A completely flexible ED, in which all beds can accommodate any patient, produced mean wait times of 35.1 minutes (95% CI 34.8 to 35.4 minutes). The results from the 3-bed flex track scenario were robust, performing well across a range of scenarios involving higher and lower patient volumes and care durations. Using discrete-event simulation, we have shown that adding some flexibility into bed allocation between low and high acuity can provide substantial reductions in overall patient waiting and a more efficient ED. Copyright © 2014 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.
Lester, Mark E; Hazelton, Jill; Dewey, William S; Casey, James C; Richard, Reginald
2013-01-01
Loss of upper extremity motion caused by axillary burn scar contracture is a major complication of burn injury. Positioning acutely injured patients with axillary burns in positions above 90° of shoulder abduction may improve shoulder motion and minimize scar contracture. However, these positions may increase injury risk to the nerves of the brachial plexus. This study evaluated the occurrence of paresthesias, pain, and positional intolerance in four shoulder abduction positions in healthy adults. Sixty men and women were placed in four randomly assigned shoulder abduction positions for up to 2 hours: 1) 90° with elbow extension (90 ABD); 2) 130° with elbow flexion at 110° (130 ABD); 3) 150° with elbow extension (150 ABD); and 4) 170° with elbow extension (170 ABD). Outcome measures were assessed at baseline and every 30 minutes and included the occurrence of upper extremity paresthesias, position comfort/tolerance, and pain. Transient paresthesias, lasting less than 3 minutes, occurred in all test positions in 10 to 37% of the cases. Significantly fewer subjects reported paresthesias in the 90 ABD position compared with the other positions (P < .01). Pain was reported more frequently in the 170° position (68%) compared with the other positions (P < .01). Positioning with the elbow flexed or in terminal extension is not recommended, regardless of the degree of shoulder abduction. Positioning patients in a position of 150° of shoulder abduction was shown to be safe and well tolerated. Consideration of positions above this range should be undertaken cautiously and only with strict monitoring in alert and oriented patients for short time periods.
Tandogan, Tamer; Auffarth, Gerd U; Choi, Chul Y; Liebing, Stephanie; Mayer, Christian; Khoramnia, Ramin
2017-02-08
To analyse objective optical properties of the spherical and aspheric design of the same intraocular lens (IOL) model using optical bench analysis. This study entailed a comparative analysis of 10 spherical C-flex 570 C and 10 aspheric C-flex 970 C IOLs (Rayner Intraocular Lenses Ltd., Hove, UK) of 26 diopters [D] using an optical bench (OptiSpheric, Trioptics, Germany). In all lenses, we evaluated the modulation transfer function (MTF) at 50 lp/mm and 100 lp/mm and the Strehl Ratio using a 3-mm (photopic) and 4.5-mm (mesopic) aperture. At 50 lp/mm, the MTF values were 0.713/0.805 (C-flex 570 C/C-flex 970 C) for a 3-mm aperture and 0.294/0.591 for a 4.5-mm aperture. At 100 lp/mm, the MTF values were 0.524/0.634 for a 3-mm aperture and 0.198/0.344 for a 4.5-mm aperture. The Strehl Ratio was 0.806/0.925 and 0.237/0.479 for a 3-mm and 4.5-mm aperture respectively. A Mann-Whitney U test revealed all intergroup differences to be statistically significant (p < 0.01). The aspheric IOL design achieved higher MTF values than the spherical design of the same IOL for both apertures. Moreover, the differences between the two designs of the IOL were more prominent for larger apertures. This suggests that the evaluated IOL provides enhanced optical quality to patients with larger pupils or working under mesopic conditions.
Ye, Bing-Wei; Lee, Kuei-Chuan; Hsieh, Yun-Cheng; Li, Chung-Pin; Chao, Yee; Hou, Ming-Chih; Lin, Han-Chieh
2015-07-01
Malignant gastric outlet obstruction is a late complication of intraabdominal malignancy. Self-expandable metallic stent placement has been a safe palliative treatment to relieve obstructive symptoms. We aimed to assess the efficacy and safety of metallic stents in our patients and analyzed the clinical outcome of different brands. Seventy-one patients with inoperable gastric outlet obstruction receiving WallFlex enteral stents (WallFlex group) or Bonastents (Bonastent group) since April 2010 were analyzed retrospectively. The overall technical and clinical success rates of stent placement were 100% and 93%, respectively. The baseline characteristics and clinical outcomes including procedure-related complications, restenosis, and reintervention rates were comparable between the 2 groups. However, the Bonastent group had a higher rate of stent fracture than the WallFlex group (13.3% vs 0%, P = 0.03). The mean duration of overall stent patency was 132.7 days. The mean duration of survival was 181.9 days. Resumption of regular diet or low residual diet at day 7 after stent insertion predicted stent patency (hazard ratio [HR]: 0.28, P = 0.01). Cancer with gastric origin (HR: 0.25, P = 0.045) and poststent chemotherapy (HR: 0.38, P = 0.006) predicted lower mortality; however, peritoneal carcinomatosis (HR: 3.09, P = 0.04) correlated with higher mortality. Metallic stent placement is a safe and effective method for relieving gastric outlet obstruction. Except higher rate of stent fracture in the Bonastent group, there is no significant difference in clinical outcomes between the Bonastent group and the WallFlex group.
Stent Design Affects Femoropopliteal Artery Deformation.
MacTaggart, Jason; Poulson, William; Seas, Andreas; Deegan, Paul; Lomneth, Carol; Desyatova, Anastasia; Maleckis, Kaspars; Kamenskiy, Alexey
2018-03-23
Poor durability of femoropopliteal artery (FPA) stenting is multifactorial, and severe FPA deformations occurring with limb flexion are likely involved. Different stent designs result in dissimilar stent-artery interactions, but the degree of these effects in the FPA is insufficiently understood. To determine how different stent designs affect limb flexion-induced FPA deformations. Retrievable markers were deployed into n = 28 FPAs of lightly embalmed human cadavers. Bodies were perfused and CT images were acquired with limbs in the standing, walking, sitting, and gardening postures. Image analysis allowed measurement of baseline FPA foreshortening, bending, and twisting associated with each posture. Markers were retrieved and 7 different stents were deployed across the adductor hiatus in the same limbs. Markers were then redeployed in the stented FPAs, and limbs were reimaged. Baseline and stented FPA deformations were compared to determine the influence of each stent design. Proximal to the stent, Innova, Supera, and SmartFlex exacerbated foreshortening, SmartFlex exacerbated twisting, and SmartControl restricted bending of the FPA. Within the stent, all devices except Viabahn restricted foreshortening; Supera, SmartControl, and AbsolutePro restricted twisting; SmartFlex and Innova exacerbated twisting; and Supera and Viabahn restricted bending. Distal to the stents, all devices except AbsolutePro and Innova exacerbated foreshortening, and Viabahn, Supera, Zilver, and SmartControl exacerbated twisting. All stents except Supera were pinched in flexed limb postures. Peripheral self-expanding stents significantly affect limb flexion-induced FPA deformations, but in different ways. Although certain designs seem to accommodate some deformation modes, no device was able to match all FPA deformations.
Evaluation of 5 different labeled polymer immunohistochemical detection systems.
Skaland, Ivar; Nordhus, Marit; Gudlaugsson, Einar; Klos, Jan; Kjellevold, Kjell H; Janssen, Emiel A M; Baak, Jan P A
2010-01-01
Immunohistochemical staining is important for diagnosis and therapeutic decision making but the results may vary when different detection systems are used. To analyze this, 5 different labeled polymer immunohistochemical detection systems, REAL EnVision, EnVision Flex, EnVision Flex+ (Dako, Glostrup, Denmark), NovoLink (Novocastra Laboratories Ltd, Newcastle Upon Tyne, UK) and UltraVision ONE (Thermo Fisher Scientific, Fremont, CA) were tested using 12 different, widely used mouse and rabbit primary antibodies, detecting nuclear, cytoplasmic, and membrane antigens. Serial sections of multitissue blocks containing 4% formaldehyde fixed paraffin embedded material were selected for their weak, moderate, and strong staining for each antibody. Specificity and sensitivity were evaluated by subjective scoring and digital image analysis. At optimal primary antibody dilution, digital image analysis showed that EnVision Flex+ was the most sensitive system (P < 0.005), with means of 8.3, 13.4, 20.2, and 41.8 gray scale values stronger staining than REAL EnVision, EnVision Flex, NovoLink, and UltraVision ONE, respectively. NovoLink was the second most sensitive system for mouse antibodies, but showed low sensitivity for rabbit antibodies. Due to low sensitivity, 2 cases with UltraVision ONE and 1 case with NovoLink stained false negatively. None of the detection systems showed any distinct false positivity, but UltraVision ONE and NovoLink consistently showed weak background staining both in negative controls and at optimal primary antibody dilution. We conclude that there are significant differences in sensitivity, specificity, costs, and total assay time in the immunohistochemical detection systems currently in use.
Self-Expandable Metallic Stent Placement in Malignant Gastric Outlet Obstruction
Ye, Bing-Wei; Lee, Kuei-Chuan; Hsieh, Yun-Cheng; Li, Chung-Pin; Chao, Yee; Hou, Ming-Chih; Lin, Han-Chieh
2015-01-01
Abstract Malignant gastric outlet obstruction is a late complication of intraabdominal malignancy. Self-expandable metallic stent placement has been a safe palliative treatment to relieve obstructive symptoms. We aimed to assess the efficacy and safety of metallic stents in our patients and analyzed the clinical outcome of different brands. Seventy-one patients with inoperable gastric outlet obstruction receiving WallFlex enteral stents (WallFlex group) or Bonastents (Bonastent group) since April 2010 were analyzed retrospectively. The overall technical and clinical success rates of stent placement were 100% and 93%, respectively. The baseline characteristics and clinical outcomes including procedure-related complications, restenosis, and reintervention rates were comparable between the 2 groups. However, the Bonastent group had a higher rate of stent fracture than the WallFlex group (13.3% vs 0%, P = 0.03). The mean duration of overall stent patency was 132.7 days. The mean duration of survival was 181.9 days. Resumption of regular diet or low residual diet at day 7 after stent insertion predicted stent patency (hazard ratio [HR]: 0.28, P = 0.01). Cancer with gastric origin (HR: 0.25, P = 0.045) and poststent chemotherapy (HR: 0.38, P = 0.006) predicted lower mortality; however, peritoneal carcinomatosis (HR: 3.09, P = 0.04) correlated with higher mortality. Metallic stent placement is a safe and effective method for relieving gastric outlet obstruction. Except higher rate of stent fracture in the Bonastent group, there is no significant difference in clinical outcomes between the Bonastent group and the WallFlex group. PMID:26200641
Conson, Massimiliano; Errico, Domenico; Mazzarella, Elisabetta; De Bellis, Francesco; Grossi, Dario; Trojano, Luigi
2015-04-01
Judgments on laterality of hand stimuli are faster and more accurate when dealing with one's own than others' hand, i.e. the self-advantage. This advantage seems to be related to activation of a sensorimotor mechanism while implicitly processing one's own hands, but not during explicit one's own hand recognition. Here, we specifically tested the influence of proprioceptive information on the self-hand advantage by manipulating participants' body posture during self and others' hand processing. In Experiment 1, right-handed healthy participants judged laterality of either self or others' hands, whereas in Experiment 2, an explicit recognition of one's own hands was required. In both experiments, the participants performed the task while holding their left or right arm flexed with their hand in direct contact with their chest ("flexed self-touch posture") or with their hand placed on a wooden smooth surface in correspondence with their chest ("flexed proprioceptive-only posture"). In an "extended control posture", both arms were extended and in contact with thighs. In Experiment 1 (hand laterality judgment), we confirmed the self-advantage and demonstrated that it was enhanced when the subjects judged left-hand stimuli at 270° orientation while keeping their left arm in the flexed proprioceptive-only posture. In Experiment 2 (explicit self-hand recognition), instead, we found an advantage for others' hand ("self-disadvantage") independently from posture manipulation. Thus, position-related proprioceptive information from left non-dominant arm can enhance sensorimotor one's own body representation selectively favouring implicit self-hands processing.
NASA Astrophysics Data System (ADS)
Stam, Frank; Kuisma, Heikki; Gao, Feng; Saarilahti, Jaakko; Gomes Martins, David; Kärkkäinen, Anu; Marrinan, Brendan; Pintal, Sebastian
2017-05-01
The deadliest disease in the world is coronary artery disease (CAD), which is related to a narrowing (stenosis) of blood vessels due to fatty deposits, plaque, on the arterial walls. The level of stenosis in the coronary arteries can be assessed by Fractional Flow Reserve (FFR) measurements. This involves determining the ratio between the maximum achievable blood flow in a diseased coronary artery and the theoretical maximum flow in a normal coronary artery. The blood flow is represented by a pressure drop, thus a pressure wire or pressure sensor integrated in a catheter can be used to calculate the ratio between the coronary pressure distal to the stenosis and the normal coronary pressure. A 2 Fr (0.67mm) outer diameter catheter was used, which required a high level of microelectronics miniaturisation to fit a pressure sensing system into the outer wall. The catheter has an eccentric guidewire lumen with a diameter of 0.43mm, which implies that the thickest catheter wall section provides less than 210 microns height for flex assembly integration consisting of two dies, a capacitive MEMS pressure sensor and an ASIC. In order to achieve this a very thin circuit flex was used, and the two chips were thinned down to 75 microns and flip chip mounted face down on the flex. Many challenges were involved in obtaining a flex layout that could wrap into a small tube without getting the dies damaged, while still maintaining enough flexibility for the catheter to navigate the arterial system.
Tsuge, Mikio; Izumizaki, Masahiko; Kigawa, Kazuyoshi; Atsumi, Takashi; Homma, Ikuo
2012-12-01
We studied the influence of false proprioceptive information generated by arm vibration and false visual information provided by a mirror in which subjects saw a reflection of another arm on perception of arm position, in a forearm position-matching task in right-handed subjects (n = 17). The mirror was placed between left and right arms, and arranged so that the reflected left arm appeared to the subjects to be their unseen right (reference) arm. The felt position of the right arm, indicated with a paddle, was influenced by vision of the mirror image of the left arm. If the left arm appeared flexed in the mirror, subjects felt their right arm to be more flexed than it was. Conversely, if the left arm was extended, they felt their right arm to be more extended than it was. When reference elbow flexors were vibrated at 70-80 Hz, an illusion of extension of the vibrated arm was elicited. The illusion of a more flexed reference arm evoked by seeing a mirror image of the flexed left arm was reduced by vibration. However, the illusion of extension of the right arm evoked by seeing a mirror image of the extended left arm was increased by vibration. That is, when the mirror and vibration illusions were in the same direction, they reinforced each other. However, when they were in opposite directions, they tended to cancel one another. The present study shows the interaction between proprioceptive and visual information in perception of arm position.
Preparing for Combat Readiness for the Fight: Physical Performance Profile of Female US Marines
2016-03-01
22.6 6 1.9 22.6 6 1.9 0.76 0.02 FFM , kg 45.5 6 4.2 44.9 6 4.3 0.05 0.14 3-mile run, min:sec 24:11 6 1:58 24:30 6 2:10 0.07 20.15 Sit-ups, reps 98.5 6...0.01 20.36 MTC, min:sec 3:28 6 0:18 3:31 6 0:22 0.04 20.14 *BMI = body mass index; FFM = fat-free mass; FAH = flexed-arm hang; AL = ammunition can...fat was calculated using the Gallagher equation (5). Fat-free mass ( FFM ) was then calculated for each individual. Owing to the testing environ- ment
Accuracy and feasibility of using an electrogoniometer for measuring simple thumb movements.
Jonsson, Per; Johnson, Peter W; Hagberg, Mats
2007-05-01
The aim of this study was to determine the accuracy and feasibility of using an electrogoniometer (Model SG 110; Biometrics, Gwent, UK) for measuring simple thumb movements. Thumb disorders have been associated with the use of hand held devices such as mobile phones and these devices have become an integral part of modern life. In 15 young subjects, the measurements of eight flexion/extension (Flex/Ext) and adduction/abduction (Ad/Ab) thumb positions were compared between a thumb-mounted electrogoniometer and manual goniometer (which was taken as the benchmark). Group mean electrogoniometric measurement errors were below 4 degrees and 5 degrees for Ad/Ab and Flex/Ext measurements, respectively. During mobile phone use, the electrogoniometers measured differences in maximal joint angle postures, which appeared to be related to differences in mobile phone size. High movement velocities may increase the risk of musculoskeletal injury and the results indicated that Ad/Ab movements were twice the speed of Flex/Ext movements during mobile phone use. Electrogoniometers have utility for studying thumb movements during mobile phone use and may be used to evaluate other thumb-based input devices.
NASA Astrophysics Data System (ADS)
Lousberg, G. P.; Lemagne, F.; Gloesener, P.; Flebus, C.; Rougelot, S.; Coatantiec, C.; Harnisch, B.
2017-11-01
In the framework of the Fluorescence Explorer (FLEX) phase A/B1 study, an elegant breadboard (EBB) of an imaging spectrometer is designed, manufactured and aligned by AMOS, with Airbus Defence&Space as the prime Contractor of the study. The FLEX mission is one of the two candidates of the 8th Earth Explorer mission. The main constituting instrument of the FLEX mission is an imaging spectrometer observing vegetation fluorescence and reflectance with a high- and a low-resolution channels in the 500 nm -780 nm band. As part of the system feasibility study of the mission, a breadboard of the high-resolution channel of the instrument is designed and manufactured with a high representativeness of a future flight concept. The high-resolution channel is referred to as FIMAS (Fluorescence IMAging Spectrometer). The main purpose of the EBB is to demonstrate (1) the manufacturability of the instrument and (2) the compliance of the optical performances with respect to the science requirements (including spatial and spectral resolution and stray-light).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Neilsen, Michael K.; Lu, Wei-Yang; Werner, Brian T.
Experiments were performed to characterize the mechanical response of a 15 pcf flexible polyurethane foam to large deformation at different strain rates and temperatures. Results from these experiments indicated that at room temperature, flexible polyurethane foams exhibit significant nonlinear elastic deformation and nearly return to their original undeformed shape when unloaded. However, when these foams are cooled to temperatures below their glass transition temperature of approximately -35 o C, they behave like rigid polyurethane foams and exhibit significant permanent deformation when compressed. Thus, a new model which captures this dramatic change in behavior with temperature was developed and implemented intomore » SIERRA with the name Flex_Foam to describe the mechanical response of both flexible and rigid foams to large deformation at a variety of temperatures and strain rates. This report includes a description of recent experiments. Next, development of the Flex Foam model for flexible polyurethane and other flexible foams is described. Selection of material parameters are discussed and finite element simulations with the new Flex Foam model are compared with experimental results to show behavior that can be captured with this new model.« less
Funk, Emily; Goldenberg, David; Goyal, Neerav
2017-06-01
Current management of laryngeal malignancies is associated with significant morbidity. Application of minimally invasive transoral techniques may reduce the morbidity associated with traditional procedures. The purpose of this study was to present our investigation of the utility of a novel flexible robotic system for transoral supraglottic laryngectomy and total laryngectomy. Transoral total laryngectomy and transoral supraglottic laryngectomy were performed in cadaveric specimens using the Flex Robotic System (Medrobotics, Raynham, MA). All procedures were completed successfully in the cadaveric models. The articulated endoscope allowed for access to the desired surgical site. Flexible instruments enabled an atraumatic approach and allowed for precise surgical technique. Access to deep anatomic structures remains problematic using current minimally invasive robotic approaches. Improvements in visualization and access to the laryngopharyngeal complex offered by this system may improve surgical applications to the larynx. This study demonstrates the technical feasibility using the Flex Robotic System for transoral robotic supraglottic laryngectomy and total laryngectomy. © 2017 Wiley Periodicals, Inc. Head Neck 39: 1218-1225, 2017. © 2017 Wiley Periodicals, Inc.
Method to improve superconductor cable
Borden, A.R.
1984-03-08
A method is disclosed of making a stranded superconductor cable having improved flexing and bending characteristics. In such method, a plurality of superconductor strands are helically wound around a cylindrical portion of a mandrel which tapers along a transitional portion to a flat end portion. The helically wound strands form a multistrand hollow cable which is partially flattened by pressure rollers as the cable travels along the transitional portion. The partially flattened cable is impacted with repeated hammer blows as the hollow cable travels along the flat end portion. The hammer blows flatten both the internal and the external surfaces of the strands. The cable is fully flattened and compacted by two sets of pressure rollers which engage the flat sides and the edges of the cable after it has traveled away from the flat end portion of the mandrel. The flattened internal surfaces slide easily over one another when the cable is flexed or bent so that there is very little possibility that the cable will be damaged by the necessary flexing and bending required to wind the cable into magnet coils.
NASA Astrophysics Data System (ADS)
Nimmy John, V.; Varanakkottu, Subramanyan Namboodiri; Varghese, Soney
2018-06-01
Flexible polymer dispersed liquid crystal (F-PDLC) devices were fabricated using transparent conducting ITO/PET film. Polymerization induced phase separation (PIPS) method was used for pure and ferroelectric BaTiO3 (BTO) and ZnO doped PDLC devices. The distribution of nanoparticles in the PDLC and the formation of micro cavities were studied using field emission scanning electron microscopy (FESEM). It was observed that the addition of ferroelectric BTO nanoparticles has reduced the threshold voltage (Vth) and saturation voltage (Vsat) of FNP-PDLC by 85% and 41% respectively due to the spontaneous polarization of ferroelectric nanoparticles. The ferroelectric properties of BTO and ZnO in the fabricated devices were investigated using dynamic contact electrostatic force microscopy (DC EFM). Flexing the device can generate a potential due to the piezo-tribo electric effect of the ferroelectric nanomaterial doped in the PDLC matrix, which could be utilized as an energy generating system. The switching voltage after multiple flexing was also studied and found to be in par with non-flexing situations.
Ankle-Dorsiflexion Range of Motion and Landing Biomechanics
Fong, Chun-Man; Blackburn, J. Troy; Norcross, Marc F.; McGrath, Melanie; Padua, Darin A.
2011-01-01
Abstract Context: A smaller amount of ankle-dorsiflexion displacement during landing is associated with less knee-flexion displacement and greater ground reaction forces, and greater ground reaction forces are associated with greater knee-valgus displacement. Additionally, restricted dorsiflexion range of motion (ROM) is associated with greater knee-valgus displacement during landing and squatting tasks. Because large ground reaction forces and valgus displacement and limited knee-flexion displacement during landing are anterior cruciate ligament (ACL) injury risk factors, dorsiflexion ROM restrictions may be associated with a greater risk of ACL injury. However, it is unclear whether clinical measures of dorsiflexion ROM are associated with landing biomechanics. Objective: To evaluate relationships between dorsiflexion ROM and landing biomechanics. Design: Descriptive laboratory study. Setting: Research laboratory. Patients or Other Participants: Thirty-five healthy, physically active volunteers. Intervention(s): Passive dorsiflexion ROM was assessed under extended-knee and flexed-knee conditions. Landing biomechanics were assessed via an optical motion-capture system interfaced with a force plate. Main Outcome Measure(s): Dorsiflexion ROM was measured in degrees using goniometry. Knee-flexion and knee-valgus displacements and vertical and posterior ground reaction forces were calculated during the landing task. Simple correlations were used to evaluate relationships between dorsiflexion ROM and each biomechanical variable. Results: Significant correlations were noted between extended-knee dorsiflexion ROM and knee-flexion displacement (r = 0.464, P = .029) and vertical (r = −0.411, P = .014) and posterior (r = −0.412, P = .014) ground reaction forces. All correlations for flexed-knee dorsiflexion ROM and knee-valgus displacement were nonsignificant. Conclusions: Greater dorsiflexion ROM was associated with greater knee-flexion displacement and smaller ground reaction forces during landing, thus inducing a landing posture consistent with reduced ACL injury risk and limiting the forces the lower extremity must absorb. These findings suggest that clinical techniques to increase plantar-flexor extensibility and dorsiflexion ROM may be important additions to ACL injury-prevention programs. PMID:21214345
Kaifu, Yousuke; Baba, Hisao; Sutikna, Thomas; Morwood, Michael J; Kubo, Daisuke; Saptomo, E Wahyu; Jatmiko; Awe, Rokhus Due; Djubiantono, Tony
2011-12-01
This paper describes in detail the external morphology of LB1/1, the nearly complete and only known cranium of Homo floresiensis. Comparisons were made with a large sample of early groups of the genus Homo to assess primitive, derived, and unique craniofacial traits of LB1 and discuss its evolution. Principal cranial shape differences between H. floresiensis and Homo sapiens are also explored metrically. The LB1 specimen exhibits a marked reductive trend in its facial skeleton, which is comparable to the H. sapiens condition and is probably associated with reduced masticatory stresses. However, LB1 is craniometrically different from H. sapiens showing an extremely small overall cranial size, and the combination of a primitive low and anteriorly narrow vault shape, a relatively prognathic face, a rounded oval foramen that is greatly separated anteriorly from the carotid canal/jugular foramen, and a unique, tall orbital shape. Whereas the neurocranium of LB1 is as small as that of some Homo habilis specimens, it exhibits laterally expanded parietals, a weak suprameatal crest, a moderately flexed occipital, a marked facial reduction, and many other derived features that characterize post-habilis Homo. Other craniofacial characteristics of LB1 include, for example, a relatively narrow frontal squama with flattened right and left sides, a marked frontal keel, posteriorly divergent temporal lines, a posteriorly flexed anteromedial corner of the mandibular fossa, a bulbous lateral end of the supraorbital torus, and a forward protruding maxillary body with a distinct infraorbital sulcus. LB1 is most similar to early Javanese Homo erectus from Sangiran and Trinil in these and other aspects. We conclude that the craniofacial morphology of LB1 is consistent with the hypothesis that H. floresiensis evolved from early Javanese H. erectus with dramatic island dwarfism. However, further field discoveries of early hominin skeletal remains from Flores and detailed analyses of the finds are needed to understand the evolutionary history of this endemic hominin species. Copyright © 2011 Elsevier Ltd. All rights reserved.
Roll-to-roll nanopatterning using jet and flash imprint lithography
NASA Astrophysics Data System (ADS)
Ahn, Sean; Ganapathisubramanian, Maha; Miller, Mike; Yang, Jack; Choi, Jin; Xu, Frank; Resnick, Douglas J.; Sreenivasan, S. V.
2012-03-01
The ability to pattern materials at the nanoscale can enable a variety of applications ranging from high density data storage, displays, photonic devices and CMOS integrated circuits to emerging applications in the biomedical and energy sectors. These applications require varying levels of pattern control, short and long range order, and have varying cost tolerances. Extremely large area R2R manufacturing on flexible substrates is ubiquitous for applications such as paper and plastic processing. It combines the benefits of high speed and inexpensive substrates to deliver a commodity product at low cost. The challenge is to extend this approach to the realm of nanopatterning and realize similar benefits. The cost of manufacturing is typically driven by speed (or throughput), tool complexity, cost of consumables (materials used, mold or master cost, etc.), substrate cost, and the downstream processing required (annealing, deposition, etching, etc.). In order to achieve low cost nanopatterning, it is imperative to move towards high speed imprinting, less complex tools, near zero waste of consumables and low cost substrates. The Jet and Flash Imprint Lithography (J-FILTM) process uses drop dispensing of UV curable resists to assist high resolution patterning for subsequent dry etch pattern transfer. The technology is actively being used to develop solutions for memory markets including Flash memory and patterned media for hard disk drives. In this paper we address the key challenges for roll based nanopatterning by introducing a novel concept: Ink Jet based Roll-to-Roll Nanopatterning. To address this challenge, we have introduced a J-FIL based demonstrator product, the LithoFlex 100. Topics that are discussed in the paper include tool design and process performance. In addition, we have used the LithoFlex 100 to fabricate high performance wire grid polarizers on flexible polycarbonate (PC) films. Transmission of better than 80% and extinction ratios on the order of 4500 have been achieved.
NASA Astrophysics Data System (ADS)
Westerhausen, Markus; Martin, Tanja; Kappel, Marcel; Hofmann, Boris
2018-02-01
We present a measurement setup consisting of two fluid-filled pressure chambers to mimic the mechanical stress likely to that of small body movements on biomedical flexible micro-electrode arrays for the analysis of various degradation mechanisms. Our main goal was the simulation of micro-motions in fluid conditions, while maintaining an electric access to the device. These micro-motions would be likely to those occurring in the human body caused by the intracranial pressure in magnitudes of 7-25 mmHg, which translates to a fluid pressure of 9-33 mbar. Furthermore, severe mechanical stress can be administered to the samples under the previously mentioned environment. Therefore, a flexible, polyimide-based sample with various metal test structures was fabricated and analyzed in the presented measurement setup. A comparison of the elongation of the sample's surface as a function of the applied hydrostatic pressure is given with computer simulations.
Development of a Temperature Sensor for Jet Engine and Space Missions Environments
NASA Technical Reports Server (NTRS)
Patterson, Richard L.; Hammoud, Ahmad; Culley, Dennis E.; Elbuluk, Malik
2008-01-01
Electronic systems in aerospace and in space exploration missions are expected to encounter extreme temperatures and wide thermal swings. To address the needs for extreme temperature electronics, research efforts exist at the NASA Glenn Research Center (GRC) to develop and evaluate electronics for extreme temperature operations, and to establish their reliability under extreme temperature operation and thermal cycling; conditions that are typical of both the aerospace and space environments. These efforts are supported by the NASA Fundamental Aeronautics/Subsonic Fixed Wing Program and by the NASA Electronic Parts and Packaging (NEPP) Program. This work reports on the results obtained on the development of a temperature sensor geared for use in harsh environments.
NASA Astrophysics Data System (ADS)
Smith, N.; Sandal, G. M.; Leon, G. R.; Kjærgaard, A.
2017-08-01
Land-based extreme environments (e.g. polar expeditions, Antarctic research stations, confinement chambers) have often been used as analog settings for spaceflight. These settings share similarities with the conditions experienced during space missions, including confinement, isolation and limited possibilities for evacuation. To determine the utility of analog settings for understanding human spaceflight, researchers have examined the extent to which the individual characteristics (e.g., personality) of people operating in extreme environments can be generalized across contexts (Sandal, 2000) [1]. Building on previous work, and utilising new and pre-existing data, the present study examined the extent to which personal value motives could be generalized across extreme environments. Four populations were assessed; mountaineers (N =59), military personnel (N = 25), Antarctic over-winterers (N = 21) and Mars simulation participants (N = 12). All participants completed the Portrait Values Questionnaire (PVQ; Schwartz; 2) capturing information on 10 personal values. Rank scores suggest that all groups identified Self-direction, Stimulation, Universalism and Benevolence as important values and acknowledged Power and Tradition as being low priorities. Results from difference testing suggest the extreme environment groups were most comparable on Self-direction, Stimulation, Benevolence, Tradition and Security. There were significant between-group differences on five of the ten values. Overall, findings pinpointed specific values that may be important for functioning in challenging environments. However, the differences that emerged on certain values highlight the importance of considering the specific population when comparing results across extreme settings. We recommend that further research examine the impact of personal value motives on indicators of adjustment, group working, and performance. Information from such studies could then be used to aid selection and training processes for personnel operating in extreme settings, and in space.
Rogers, John A; Meitl, Matthew; Sun, Yugang; Ko, Heung Cho; Carlson, Andrew; Choi, Won Mook; Stoykovich, Mark; Jiang, Hanqing; Huang, Yonggang; Nuzzo, Ralph G; Zhu, Zhengtao; Menard, Etienne; Khang, Dahl-Young
2014-05-20
In an aspect, the present invention provides stretchable, and optionally printable, components such as semiconductors and electronic circuits capable of providing good performance when stretched, compressed, flexed or otherwise deformed, and related methods of making or tuning such stretchable components. Stretchable semiconductors and electronic circuits preferred for some applications are flexible, in addition to being stretchable, and thus are capable of significant elongation, flexing, bending or other deformation along one or more axes. Further, stretchable semiconductors and electronic circuits of the present invention are adapted to a wide range of device configurations to provide fully flexible electronic and optoelectronic devices.
Rogers, John A [Champaign, IL; Meitl, Matthew [Raleigh, NC; Sun, Yugang [Naperville, IL; Ko, Heung Cho [Urbana, IL; Carlson, Andrew [Urbana, IL; Choi, Won Mook [Champaign, IL; Stoykovich, Mark [Dover, NH; Jiang, Hanqing [Urbana, IL; Huang, Yonggang [Glencoe, IL; Nuzzo, Ralph G [Champaign, IL; Lee, Keon Jae [Tokyo, JP; Zhu, Zhengtao [Rapid City, SD; Menard, Etienne [Durham, NC; Khang, Dahl-Young [Seoul, KR; Kan, Seong Jun [Daejeon, KR; Ahn, Jong Hyun [Suwon, KR; Kim, Hoon-sik [Champaign, IL
2012-07-10
In an aspect, the present invention provides stretchable, and optionally printable, components such as semiconductors and electronic circuits capable of providing good performance when stretched, compressed, flexed or otherwise deformed, and related methods of making or tuning such stretchable components. Stretchable semiconductors and electronic circuits preferred for some applications are flexible, in addition to being stretchable, and thus are capable of significant elongation, flexing, bending or other deformation along one or more axes. Further, stretchable semiconductors and electronic circuits of the present invention are adapted to a wide range of device configurations to provide fully flexible electronic and optoelectronic devices.
Yan, Xin-Zhong; Ting, C S
2006-08-11
On the basis of the Hubbard model, we extend the fluctuation-exchange (FLEX) approach to investigating the properties of the antiferromagnetic (AF) phase in electron-doped cuprate superconductors. Furthermore, by incorporating the effect of scatterings due to the disordered dopant atoms into the FLEX formalism, our numerical results show that the antiferromagnetic transition temperature, the onset temperature of pseudogap due to spin fluctuations, the spectral density of the single particle near the Fermi surface, and the staggered magnetization in the AF phase as a function of electron doping can consistently account for the experimental measurements.
Embedded I&C for Extreme Environments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kisner, Roger A.
2016-04-01
This project uses embedded instrumentation and control (I&C) technologies to demonstrate potential performance gains of nuclear power plant components in extreme environments. Extreme environments include high temperature, radiation, high pressure, high vibration, and high EMI conditions. For extreme environments, performance gains arise from moment-to-moment sensing of local variables and immediate application of local feedback control. Planning for embedding I&C during early system design phases contrasts with the traditional, serial design approach that incorporates minimal I&C after mechanical and electrical design is complete. The demonstration application involves the development and control of a novel, proof-of-concept motor/pump design. The motor and pumpmore » combination operate within the fluid environment, eliminating the need for rotating seals. Actively controlled magnetic bearings also replace failure-prone mechanical contact bearings that typically suspend rotating components. Such as design has the potential to significantly enhance the reliability and life of the pumping system and would not be possible without embedded I&C.« less
Electronics for Extreme Environments
NASA Astrophysics Data System (ADS)
Patel, J. U.; Cressler, J.; Li, Y.; Niu, G.
2001-01-01
Most of the NASA missions involve extreme environments comprising radiation and low or high temperatures. Current practice of providing friendly ambient operating environment to electronics costs considerable power and mass (for shielding). Immediate missions such as the Europa orbiter and lander and Mars landers require the electronics to perform reliably in extreme conditions during the most critical part of the mission. Some other missions planned in the future also involve substantial surface activity in terms of measurements, sample collection, penetration through ice and crust and the analysis of samples. Thus it is extremely critical to develop electronics that could reliably operate under extreme space environments. Silicon On Insulator (SOI) technology is an extremely attractive candidate for NASA's future low power and high speed electronic systems because it offers increased transconductance, decreased sub-threshold slope, reduced short channel effects, elimination of kink effect, enhanced low field mobility, and immunity from radiation induced latch-up. A common belief that semiconductor devices function better at low temperatures is generally true for bulk devices but it does not hold true for deep sub-micron SOI CMOS devices with microscopic device features of 0.25 micrometers and smaller. Various temperature sensitive device parameters and device characteristics have recently been reported in the literature. Behavior of state of the art technology devices under such conditions needs to be evaluated in order to determine possible modifications in the device design for better performance and survivability under extreme environments. Here, we present a unique approach of developing electronics for extreme environments to benefit future NASA missions as described above. This will also benefit other long transit/life time missions such as the solar sail and planetary outposts in which electronics is out open in the unshielded space at the ambient space temperatures and always exposed to radiation. Additional information is contained in the original extended abstract.
On the edge of a deep biosphere: Real animals in extreme environments
NASA Astrophysics Data System (ADS)
Childress, James J.; Fisher, Charles F.; Felbeck, Horst; Girguis, Peter
This paper considers the possibility of animals living in a subsurface environment on the global mid-ocean ridge system. It considers the possible environments and looks at the possibilities of animal inhabitants of the subsurface biosphere based on adaptations of animals to other extreme habitats. We conclude that there are known bridging inhabitants of the subsurface biosphere, that part-time inhabitants are extremely likely, and that there could be full-time inhabitants if conditions are stable within the tolerance limits of metazoans for time periods of months.
Instrument pre-development activities for FLEX
NASA Astrophysics Data System (ADS)
Pettinato, L.; Fossati, E.; Coppo, P. M.; Taiti, A.; Labate, D.; Capanni, A.; Taccola, M.; Bézy, J. L.; Francois, M.; Meynart, R.; Erdmann, L.; Triebel, P.
2017-09-01
The FLuorescence Imaging Spectrometer (FLORIS) is the payload of the FLuorescence Explorer Mission (FLEX) of the European Space Agency. The mission objective is to perform quantitative measurements of the solar induced vegetation fluorescence to monitor photosynthetic activity. FLORIS works in a push-broom configuration and it is designed to acquire data in the 500-780 nm spectral range, with a sampling of 0.1 nm in the oxygen bands (759-769 nm and 686- 697 nm) and 0.5-2.0 nm in the red edge, chlorophyll absorption and Photochemical Reflectance Index bands. FLEX will fly in formation with Sentinel-3 to benefit of the measurements made by the Sentinel-3 instruments OLCI and SLSTR, particularly for cloud screening, proper characterization of the atmospheric state and determination of the surface temperature. The instrument concept is based on a common telescope and two modified Offner spectrometers with reflective concave gratings both for the High Resolution (HR) and Low Resolution (LR) spectrometers. In the frame of the instrument pre-development Leonardo Company (I) has built and tested an elegant breadboard of the instrument consisting of the telescope and the HR spectrometer. The development of the LR spectrometer is in charge of OHB System AG (D) and is currently in the manufacturing phase. The main objectives of the activity are: anticipate the development of the instrument and provide early risk retirement of critical components, evaluate the system performances such as imaging quality parameters, straylight, ghost, polarization sensitivity and environmental influences, verify the adequacy of critical tests such as spectral characterization and straylight, define and optimize instrument alignment procedures. Following a brief overview of the FLEX mission, the paper will cover the design and the development of the optics breadboard with emphasis on the results obtained during the tests and the lessons learned for the flight unit.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Urlings, T. A. J., E-mail: t-urlings@hotmail.com; Vries, A. C. de, E-mail: a.de.vries@mchaaglanden.nl; Mol van Otterloo, J. C. A. de, E-mail: a.de.molvanotterloo@mchaaglanden.nl
2015-06-15
PurposeThe purpose of this study was to objectify and evaluate risk factors for thromboembolic complications after treatment with a Zenith{sup ®} Low Profile Endovascular Graft (Zenith LP). Results were compared with those in the recent literature on endovascular aortic repair (EVAR) and with the thromboembolic complications in the patient group treated with a Zenith Flex Endovascular Graft in our institute in the period before the use of the Zenith LP.Materials and MethodsAll consecutive patients who were suitable for treatment with a Zenith LP endograft between October 2010 and December 2011 were included. The preprocedural computed tomography scan (CT), procedural angiographicmore » images, and the postprocedural CT scans were evaluated for risk factors for and signs of thromboembolic complications. All patients treated between December 2007 and November 2012 with a Zenith Flex endograft were retrospectively evaluated for thromboembolic complications.ResultsIn the study period 17 patients were treated with a LP Zenith endograft. Limb occlusion occurred in 35 % of the patients. Limb occlusions occurred in 24 % of the limbs at risk (one limb occluded twice). In one patient two risk factors for limb occlusion were identified. Between December 2007 and November 2012, a total of 43 patients were treated with a Zenith Flex endograft. No limb occlusion or distal embolization occurred.ConclusionDespite that this was a small retrospective study, the Zenith LP endograft seems to be associated with more frequent thromboembolic complications compared with the known limb occlusion rates in the literature and those of the patients treated with a Zenith Flex endograft in our institute.« less
Cai, J-J; Tang, X-N; Ge, J-Y
2017-07-01
To investigate the effect of irrigation on the surface roughness and fatigue resistance of HyFlex and M3 controlled memory (CM) wire nickel-titanium instruments. Two new files of each brand were analysed by atomic force microscopy (AFM). Then, the instruments were dynamically immersed in either 5.25% sodium hypochlorite (NaOCl) or 17% ethylene diamine tetraacetic acid (EDTA) solution for 10 min, followed by AFM analysis. The roughness average (Ra) and root mean square (RMS) values were analysed statistically using an independent sample t-test. Then, 36 files of each brand were randomly assigned to three groups (n = 12). Group 1 (the control group) was composed of new instruments. Groups 2 and 3 were dynamically immersed in 5.25% NaOCl and 17% EDTA solutions for 10 min, respectively. The number of rotations to failure for various groups was analysed using the one-way analysis of variance software. For M3 files, the Ra and RMS values significantly increased (P < 0.05) after the immersion. For the HyFlex file, the Ra and RMS values significantly increased (P < 0.05) only in EDTA, but not (P > 0.05) NaOCl. The resistance to cyclic fatigue of both HyFlex and M3 files did not significantly decrease (P > 0.05) by immersing in 5.25% NaOCl and 17% EDTA solutions. Except the HyFlex files immersed in NaOCl, the surface roughness of other files exposed to irrigants increased. However, a change in the surface tomography of CM wire instruments caused by contact with irrigants for 10 min did not trigger a decrease in cyclic fatigue resistance. © 2016 International Endodontic Journal. Published by John Wiley & Sons Ltd.
Böhm, Harald; Hösl, Matthias; Döderlein, Leonhard
2017-05-01
Patellar tendon shortening procedure within single event multilevel surgeries was shown to improve crouch gait in Cerebral Palsy (CP) patients. However, one of the drawbacks associated to the correction of flexed knee gait may be increased pelvic anterior tilt with compensatory lumbar lordosis. Which CP patients are at risk for excessive anterior pelvic tilt following correction of flexed knee gait including patellar tendon shortening? 32 patients with CP between 8 and 18 years GMFCS I&II were included. They received patellar tendon shortenings within multilevel surgery. Patients with concomitant knee flexor lengthening were excluded. Gait analysis and clinical testing was performed pre- and 24.1 (SD=1.9) months postoperatively. Patients were subdivided into more/less than 5° increase in anterior pelvic tilt. Preoperative measures indicating m. rectus and m. psoas shortness, knee flexor over-length, hip extensor and abdominal muscle weakness and equinus gait were compared between groups. Stepwise multilinear regression of the response value increase in pelvic tilt during stance phase was performed from parameters that were significantly different between groups. 34% of patients showed more than 5° increased pelvic anterior tilt postoperatively. Best predictors for anterior pelvic tilt from preoperative measures were increased m. rectus tone and reduced hip extension during walking that explained together 39% of the variance in increase of anterior pelvic tilt. Every third patient showed considerable increased pelvic tilt following surgery of flexed knee gait. In particular patients with preoperative higher muscle tone in m. rectus and lower hip extension during walking were at risk and both features need to be addressed in the therapy. Copyright © 2017 Elsevier B.V. All rights reserved.
Aeroelastic Airworthiness Assesment of the Adaptive Compliant Trailing Edge Flaps
NASA Technical Reports Server (NTRS)
Herrera, Claudia Y.; Spivey, Natalie D.; Lung, Shun-fat; Ervin, Gregory; Flick, Peter
2015-01-01
The Adaptive Compliant Trailing Edge (ACTE) demonstrator is a joint task under the National Aeronautics and Space Administration Environmentally Responsible Aviation Project in partnership with the Air Force Research Laboratory and FlexSys, Inc. (Ann Arbor, Michigan). The project goal is to develop advanced technologies that enable environmentally friendly aircraft, such as adaptive compliant technologies. The ACTE demonstrator flight-test program encompassed replacing the Fowler flaps on the SubsoniC Aircraft Testbed, a modified Gulfstream III (Gulfstream Aerospace, Savannah, Georgia) aircraft, with control surfaces developed by FlexSys. The control surfaces developed by FlexSys are a pair of uniquely-designed unconventional flaps to be used as lifting surfaces during flight-testing to validate their structural effectiveness. The unconventional flaps required a multidisciplinary airworthiness assessment to prove they could withstand the prescribed flight envelope. Several challenges were posed due to the large deflections experienced by the structure, requiring non-linear analysis methods. The aeroelastic assessment necessitated both conventional and extensive testing and analysis methods. A series of ground vibration tests (GVTs) were conducted to provide modal characteristics to validate and update finite element models (FEMs) used for the flutter analyses for a subset of the various flight configurations. Numerous FEMs were developed using data from FlexSys and the ground tests. The flap FEMs were then attached to the aircraft model to generate a combined FEM that could be analyzed for aeroelastic instabilities. The aeroelastic analysis results showed the combined system of aircraft and flaps were predicted to have the required flutter margin to successfully demonstrate the adaptive compliant technology. This paper documents the details of the aeroelastic airworthiness assessment described, including the ground testing and analyses, and subsequent flight-testing performed on the unconventional ACTE flaps.
Opacification of AcriFlex 50CSE hydrophilic acrylic intraocular lenses.
Lim, Andrew Keat Eu; Goh, Pik Pin; Azura, Ramlee; Mariam, Ismail
2011-04-01
To determine the prevalence of and risk factors for AcriFlex 50CSE hydrophilic acrylic intraocular lens (IOL) opacification approximately 3 years after implantation. Selayang Hospital, Selangor, Malaysia. Cross-sectional study. Patients who had AcriFlex 50CSE IOL implantation in 2005 and 2006 were identified from operating logbooks and recalled via telephone and letters. Opaque IOLs were explanted and sent for scanning electron microscopy (SEM) and energy-dispersive x-ray spectroscopy (EDS). The review showed that 18 patients had died and 67 had declined examination or could not be contacted, leaving 239 eyes for evaluation. The age of the patients ranged from 25 to 85 years. Of the patients, 83 (34.7%) were Malay, 127 (53.1%) Chinese, and 29 (12.1%) East Indian. The male:female ratio was 1:1. Fourteen eyes of 13 patients (5.4%) had IOL opacification; 1 had bilateral opacification. Five eyes had fine deposits, and 9 eyes had dense opaque deposits. Seven opaque IOLs required explantation. There was no correlation between age (P=.645), sex (P=.319), or race (P=.860) and IOL opacification. Pearson chi-square analysis showed a strong association between diabetes mellitus and IOL opacification (P=.019). Nine (69.2%) of the 13 patients with opacification had diabetes. Scanning electron microscopy and EDS showed calcium and phosphate deposits on the optic surface and intralenticularly near the anterior surface of the optic. Results indicate that diabetes mellitus is a risk factor for AcriFlex hydrophilic acrylic IOL opacification. In some cases, opacification affected vision, necessitating explantation. The pathophysiology of this complication is unknown. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Fatalla, Abdalbseet A; Song, Ke; Du, Tianfeng; Cao, Yingguang
2012-12-01
The aim of this study was to establish the optimum design and attachment combination to support an overdenture with minimal stress and flexing produced in the alveolar bone surrounding any natural teeth and/or mini dental implants. Twelve models were included in the study: the six main models (A, B, C, D, E, and F) were categorized according to the support designs of the overdenture prosthesis, and each model was further subdivided according to the attachment combinations into model 1: with Dalbo elliptic and/or O-ring attachments only and model 2: with flexible acrylic attachments. Vertical loads (35 N) and 17.5 N lateral loads under static conditions were applied to the models to simulate the occlusal forces following the concept of lingualized occlusion. All conditions were created using a finite element software program. Maximum von Mises stress at the level of the attachments and at the bone support foundation interfaces were compared in all 12 models. The flexing of the mandible and the attachments were also compared qualitatively. Stress on these models was analyzed after the given loading condition. The results showed that the model with three freestanding mini dental implants and flexible acrylic attachments showed the lowest von Mises stress and flexing, while the models with four freestanding mini dental implants and O-ring attachments showed the highest von Mises stress. Three freestanding mini dental implants with flexible acrylic attachment systems supporting an overdenture were better choices than four mini dental implants with O-ring attachment systems, which showed the maximum flexing and stress values in this qualitative comparison. © 2012 by the American College of Prosthodontists.
Dosing Accuracy of Insulin Aspart FlexPens After Transport Through the Pneumatic Tube System.
Ward, Leah G; Heckman, Michael G; Warren, Amy I; Tran, Kimberly
2013-01-01
The purpose of this study was to evaluate whether transporting insulin aspart FlexPens via a pneumatic tube system affects the dosing accuracy of the pens. A total of 115 Novo Nordisk FlexPens containing insulin aspart were randomly assigned to be transported via a pneumatic tube system (n = 92) or to serve as the control (n = 23). Each pen was then randomized to 10 international unit (IU) doses (n = 25) or 30 IU doses (n = 67), providing 600 and 603 doses, respectively, for the pneumatic tube group. The control group also received random assignment to 10 IU doses (n = 6) or 30 IU doses (n = 17), providing 144 and 153 doses, respectively. Each dose was expelled using manufacturer instructions. Weights were recorded, corrected for specific gravity, and evaluated based on acceptable International Organization for Standardization (ISO) dosing limits. In the group of pens transported through the pneumatic tube system, none of the 600 doses of 10 IU (0.0%; 95% CI, 0.0 to 0.6) and none of the 603 doses of 30 IU (0.0%; 95% CI, 0.0 to 0.6) fell outside of the range of acceptable weights. Correspondingly, in the control group, none of the 144 doses at 10 IU (0.0%; 95% CI, 0.0 to 2.5) and none of the 153 doses at 30 IU (0.0%; 95% CI, 0.0 to 2.4) were outside of acceptable ISO limits. Transportation via pneumatic tube system does not appear to compromise dosing accuracy. Hospital pharmacies may rely on the pneumatic tube system for timely and accurate transport of insulin aspart FlexPens.
Zhu, C; Yi, N; Shi, M N; Liang, Y Y; Zhou, Y B; Dang, R; Qi, Z S; Zhao, H Y
2017-07-20
Objective: To observe the effects of functional training combined with self-made hand flexing training band in treatment of scar contracture after burn injury of dorsal hand. Methods: Forty-six patients with scar contracture after deep partial-thickness or full-thickness burn injury of dorsal hand hospitalized in our department from March 2013 to February 2015 were divided into routine training group (RT, n =18) and comprehensive training group (CT, n =28) according to their willingness. Two weeks after the wounds were healed, patients in group RT were treated with functional training of hands and self-made pressure gloves, while patients in group CT were treated with self-made hand flexing training band (consisting of nylon strap, flexing band, and velcro) on the basis of those in group RT. All patients were treated for 3 months. Before and after treatment, scar condition of affected hands was assessed with Vancouver Scar Scale (VSS). The range of motion of joints of affected hands was measured by Total Active Movement (TAM) Scale. The function of affected hands was evaluated by Carroll Upper Extremity Function Test. Data were processed with t test, chi-square test, and Mann-Whitney U test. Results: (1) The score of VSS in patients of group RT was (10.0±1.9) points before treatment and (4.4±1.4) points after treatment, with the improved score of (5.6±1.0) points. The score of VSS in patients of group CT was (10.5±1.8) points before treatment and (4.6±1.4) points after treatment, with the improved score of (5.9±1.2) points. There was no statistically significant difference in the improved score of patients between the two groups ( t =0.834, P >0.05). The score of VSS in patients of groups RT and CT after treatment was significantly lower than that before treatment (with t values respectively 14.014 and 10.003, P values below 0.01). (2) Before treatment, the ratios of excellent and good results according to TAM were 2/9 in patients of group RT and 3/14 in group CT, with no statistical differences between them ( χ (2)=2.140, P >0.05). After treatment, the ratio of excellent and good results according to TAM in patients of group CT (6/7) was higher than that in group RT (5/9, χ (2)=0.023, P =0.038). The ratios of excellent and good results according to TAM in patients of groups RT and CT after treatment were significantly higher than those before treatment (with Z values respectively -2.023 and -4.780, P values below 0.05). (3) The improved score of hand function in patients of group CT was (26±12) points, which was higher than (15±7) points in group RT ( t =3.278, P =0.002). The score of hand function in patients of groups RT and CT after treatment was significantly higher than that before treatment (with t values respectively 2.628 and 6.125, P values below 0.05). There were no significant differences in grades of hand function of patients between the two groups before treatment ( Z =-0.286, P >0.05). After treatment, the grade of hand function in patients of group CT was higher than that in group RT( Z =-1.993, P =0.046). The grades of hand function in patients of groups RT and CT after treatment were significantly higher than those before treatment (with Z values respectively -2.717 and -4.998, P values below 0.01). Conclusions: For patients with scar contracture after burn injury of dorsal hand, early functional training combined with hand flexing training band can improve the range of motion of hand joints and functional recovery of hand, and the result was better than functional training alone.
Universal Controller for Spacecraft Mechanisms
NASA Technical Reports Server (NTRS)
Levanas, Greg; McCarthy, Thomas; Hunter, Don; Buchanan, Christine; Johnson, Michael; Cozy, Raymond; Morgan, Albert; Tran, Hung
2006-01-01
An electronic control unit has been fabricated and tested that can be replicated as a universal interface between the electronic infrastructure of a spacecraft and a brushless-motor (or other electromechanical actuator) driven mechanism that performs a specific mechanical function within the overall spacecraft system. The unit includes interfaces to a variety of spacecraft sensors, power outputs, and has selectable actuator control parameters making the assembly a mechanism controller. Several control topologies are selectable and reconfigurable at any time. This allows the same actuator to perform different functions during the mission life of the spacecraft. The unit includes complementary metal oxide/semiconductor electronic components on a circuit board of a type called rigid flex (signifying flexible printed wiring along with a rigid substrate). The rigid flex board is folded to make the unit fit into a housing on the back of a motor. The assembly has redundant critical interfaces, allowing the controller to perform time-critical operations when no human interface with the hardware is possible. The controller is designed to function over a wide temperature range without the need for thermal control, including withstanding significant thermal cycling, making it usable in nearly all environments that spacecraft or landers will endure. A prototype has withstood 1,500 thermal cycles between 120 and +85 C without significant deterioration of its packaging or electronic function. Because there is no need for thermal control and the unit is addressed through a serial bus interface, the cabling and other system hardware are substantially reduced in quantity and complexity, with corresponding reductions in overall spacecraft mass and cost.
Vibration Isolation for Launch of a Space Station Orbital Replacement Unit
NASA Technical Reports Server (NTRS)
Maly, Joseph R.; Sills, Joel W., Jr.; Pendleton, Scott C.; James, George H., III; Mimovich, Mark
2004-01-01
Delivery of Orbital Replacement Units (ORUs) to on-orbit destinations such a the International Space Station (ISS) and the Hubble Space Telescope is an important component of the space program. ORUs are integrated on orbit with space assets to maintain and upgrade functionality. For ORUs comprised of sensitive equipment, the dynamic launch environment drives design and testing requirements, and high frequency random vibrations are generally the cause for failure. Vibration isolation can mitigate the structure-borne vibration environment during launch, and hardware has been developed that can provide a reduced environment for current and future launch environments. Random vibration testing of one ORU to equivalent Space Shuttle launch levels revealed that its qualification and acceptance requirements were exceeded. An isolation system was designed to mitigate the structure-borne launch vibration environment. To protect this ORU, the random vibration levels at 50 Hz must be attenuated by a factor of two and those at higher frequencies even more. Design load factors for Shuttle launch are high, so a metallic load path is needed to maintain strength margins. Isolation system design was performed using a finite element model of the ORU on its carrier with representative disturbance inputs. Iterations on the modelled to an optimized design based on flight proven SoftRide MultiFlex isolators. Component testing has been performed on prototype isolators to validate analytical predictions.
Automation Rover for Extreme Environments
NASA Technical Reports Server (NTRS)
Sauder, Jonathan; Hilgemann, Evan; Johnson, Michael; Parness, Aaron; Hall, Jeffrey; Kawata, Jessie; Stack, Kathryn
2017-01-01
Almost 2,300 years ago the ancient Greeks built the Antikythera automaton. This purely mechanical computer accurately predicted past and future astronomical events long before electronics existed1. Automata have been credibly used for hundreds of years as computers, art pieces, and clocks. However, in the past several decades automata have become less popular as the capabilities of electronics increased, leaving them an unexplored solution for robotic spacecraft. The Automaton Rover for Extreme Environments (AREE) proposes an exciting paradigm shift from electronics to a fully mechanical system, enabling longitudinal exploration of the most extreme environments within the solar system.
Developing science gateways for drug discovery in a grid environment.
Pérez-Sánchez, Horacio; Rezaei, Vahid; Mezhuyev, Vitaliy; Man, Duhu; Peña-García, Jorge; den-Haan, Helena; Gesing, Sandra
2016-01-01
Methods for in silico screening of large databases of molecules increasingly complement and replace experimental techniques to discover novel compounds to combat diseases. As these techniques become more complex and computationally costly we are faced with an increasing problem to provide the research community of life sciences with a convenient tool for high-throughput virtual screening on distributed computing resources. To this end, we recently integrated the biophysics-based drug-screening program FlexScreen into a service, applicable for large-scale parallel screening and reusable in the context of scientific workflows. Our implementation is based on Pipeline Pilot and Simple Object Access Protocol and provides an easy-to-use graphical user interface to construct complex workflows, which can be executed on distributed computing resources, thus accelerating the throughput by several orders of magnitude.
Micrometeorite Impact Test of Flex Solar Array Coupon
NASA Technical Reports Server (NTRS)
Wright, K. H.; Schneider, T. A.; Vaughn, J. A.; Hoang, B.; Wong, F.; Gardiner, G.
2016-01-01
Spacecraft with solar arrays operate throughout the near earth environment and are planned for outer planet missions. An often overlooked test condition for solar arrays that is applicable to these missions is micrometeoroid impacts and possibly electrostatic discharge (ESD) events resulting from these impacts. NASA Marshall Space Flight Center (MSFC) is partnering with Space Systems/Loral, LLC (SSL) to examine the results of simulated micrometeoroid impacts on the electrical performance of an advanced, lightweight flexible solar array design. The test is performed at MSFC's Micro Light Gas Gun Facility with SSL-provided coupons. Multiple impacts were induced at various locations on a powered test coupon under different string voltage (0V-150V) and string current (1.1A - 1.65A) conditions. The setup, checkout, and results from the impact testing are discussed.
Design of Launch Vehicle Flight Control Systems Using Ascent Vehicle Stability Analysis Tool
NASA Technical Reports Server (NTRS)
Jang, Jiann-Woei; Alaniz, Abran; Hall, Robert; Bedossian, Nazareth; Hall, Charles; Jackson, Mark
2011-01-01
A launch vehicle represents a complicated flex-body structural environment for flight control system design. The Ascent-vehicle Stability Analysis Tool (ASAT) is developed to address the complicity in design and analysis of a launch vehicle. The design objective for the flight control system of a launch vehicle is to best follow guidance commands while robustly maintaining system stability. A constrained optimization approach takes the advantage of modern computational control techniques to simultaneously design multiple control systems in compliance with required design specs. "Tower Clearance" and "Load Relief" designs have been achieved for liftoff and max dynamic pressure flight regions, respectively, in the presence of large wind disturbances. The robustness of the flight control system designs has been verified in the frequency domain Monte Carlo analysis using ASAT.
Molecular docking analysis of known flavonoids as duel COX-2 inhibitors in the context of cancer
Dash, Raju; Uddin, Mir Muhammad Nasir; Hosen, S.M. Zahid; Rahim, Zahed Bin; Dinar, Abu Mansur; Kabir, Mohammad Shah Hafez; Sultan, Ramiz Ahmed; Islam, Ashekul; Hossain, Md Kamrul
2015-01-01
Cyclooxygenase-2 (COX-2) catalyzed synthesis of prostaglandin E2 and it associates with tumor growth, infiltration, and metastasis in preclinical experiments. Known inhibitors against COX-2 exhibit toxicity. Therefore, it is of interest to screen natural compounds like flavanoids against COX-2. Molecular docking using 12 known flavanoids against COX-2 by FlexX and of ArgusLab were performed. All compounds showed a favourable binding energy of >-10 KJ/mol in FlexX and > -8 kcal/mol in ArgusLab. However, this data requires in vitro and in vivo verification for further consideration. PMID:26770028
Conservative management of pes valgus with plantar flexed talus, flexible.
Bleck, E E; Berzins, U J
1977-01-01
The type of flat foot that we have called pes valgus with plantar flexed talus, flexible, was treated in children with the Helfet heel seat or the UCBL shoe insert. In follow-up examination of 71 cases for periods longer than one year, 79 per cent of the patients showed that the UCBL shoe insert and the Helfet heel seat improved the clinical and roentgenographic appearance of the foot. The Helfet heel seat is recommended in cases where the plantar flexion angle of the talus is 35 to 45 degrees and the UCBL shoe insert in those cases of plantar flexion of the talus greater than 45 degrees.
Development of an Ultraflex-Based Thin Film Solar Array for Space Applications
NASA Technical Reports Server (NTRS)
White, Steve; Douglas, Mark; Spence, Brian; Jones, P. Alan; Piszczor, Michael F.
2003-01-01
As flexible thin film photovoltaic (FTFPV) cell technology is developed for space applications, integration into a viable solar array structure that optimizes the attributes of this cell technology is critical. An advanced version of ABLE'sS UltraFlex solar array platform represents a near-term, low-risk approach to demonstrating outstanding array performance with the implementation of FTFPV technology. Recent studies indicate that an advanced UltraFlex solar array populated with 15% efficient thin film cells can achieve over 200 W/kg EOL. An overview on the status of hardware development and the future potential of this technology is presented.
Performance of FORTRAN floating-point operations on the Flex/32 multicomputer
NASA Technical Reports Server (NTRS)
Crockett, Thomas W.
1987-01-01
A series of experiments has been run to examine the floating-point performance of FORTRAN programs on the Flex/32 (Trademark) computer. The experiments are described, and the timing results are presented. The time required to execute a floating-point operation is found to vary considerbaly depending on a number of factors. One factor of particular interest from an algorithm design standpoint is the difference in speed between common memory accesses and local memory accesses. Common memory accesses were found to be slower, and guidelines are given for determinig when it may be cost effective to copy data from common to local memory.
Intelligent content fitting for digital publishing
NASA Astrophysics Data System (ADS)
Lin, Xiaofan
2006-02-01
One recurring problem in Variable Data Printing (VDP) is that the existing contents cannot satisfy the VDP task as-is. So there is a strong need for content fitting technologies to support high-value digital publishing applications, in which text and image are the two major types of contents. This paper presents meta-Autocrop framework for image fitting and TextFlex technology for text fitting. The meta-Autocrop framework supports multiple modes: fixed aspect-ratio mode, advice mode, and verification mode. The TextFlex technology supports non-rectangular text wrapping and paragraph-based line breaking. We also demonstrate how these content fitting technologies are utilized in the overall automated composition and layout system.
The influence of golf shaft stiffness on grip and clubhead kinematics.
MacKenzie, Sasho J; Boucher, Daniel E
2017-01-01
The purpose of this study was to investigate the influence of shaft stiffness on grip and clubhead kinematics. Two driver shafts with disparate levels of stiffness, but very similar inertial properties, were tested by 33 golfers representing a range of abilities. Shaft deflection data as well as grip and clubhead kinematics were collected from 14 swings, with each shaft, for each golfer using an optical motion capture system. The more flexible shaft (R-Flex) demonstrated a higher contribution to clubhead speed from shaft deflection dynamics (P < .001), but was also associated with significantly less grip angular velocity at impact (P = .001), resulting in no significant difference in clubhead speed (P = .14). However, at the individual level, half of the participants demonstrated a significant difference in clubhead speed between shafts. The more flexible shaft was also associated with significantly different magnitudes of head rotation relative to the grip. More specifically, both bend loft (P < .001) and bend lie (P < .001) were greater for the R-Flex shaft, while bend close (P = .017) was greater for the stiffer (X-Flex) shaft. However, changes in grip orientation resulted in no significant differences in face orientation, between the shafts, at impact.
Static Noise Margin Enhancement by Flex-Pass-Gate SRAM
NASA Astrophysics Data System (ADS)
O'Uchi, Shin-Ichi; Masahara, Meishoku; Sakamoto, Kunihiro; Endo, Kazuhiko; Liu, Yungxun; Matsukawa, Takashi; Sekigawa, Toshihiro; Koike, Hanpei; Suzuki, Eiichi
A Flex-Pass-Gate SRAM, i.e. a fin-type-field-effect-transistor- (FinFET-) based SRAM, is proposed to enhance noise margin during both read and write operations. In its cell, the flip-flop is composed of usual three-terminal- (3T-) FinFETs while pass gates are composed of four-terminal- (4T-) FinFETs. The 4T-FinFETs enable to adopt a dynamic threshold-voltage control in the pass gates. During a write operation, the threshold voltage of the pass gates is lowered to enhance the writing speed and stability. During the read operation, on the other hand, the threshold voltage is raised to enhance the static noise margin. An asymmetric-oxide 4T-FinFET is helpful to manage the leakage current through the pass gate. In this paper, a design strategy of the pass gate with an asymmetric gate oxide is considered, and a TCAD-based Monte Carlo simulation reveals that the Flex-Pass-Gate SRAM based on that design strategy is expected to be effective in half-pitch 32-nm technology for low-standby-power (LSTP) applications, even taking into account the variability in the device performance.
Eliminating impingement optimizes patellar biomechanics in high knee flexion.
Tang, Qi-heng; Zhou, Yi-xin; Tang, Jing; Shao, Hong-yi; Wang, Guang-zhi
2010-08-01
We investigated the impact of eliminating the impingement between extensor mechanism and tibial insert on patellar tracking and patellar ligament tension in high knee flexion. Six cadaveric specimens were tested on an Oxford-type testing rig. The Genesis II knee system was implanted into each specimen knee with the traditional tibial insert and high-flex insert successively. Compared to traditional insert, the high-flex insert was characterized with a chambered anterior post and a chambered anterior lip which eliminates patella-post and patellar ligament-anterior lip impingements. The patella was tracked with an NDI Optotrak Certus system. The patellar ligament tension was measured using a NKB S-type tension transducer. There was a decrease of resultant patellar translation relative to the femur with statistically significant (P<0.05) at 90 degrees to 150 degrees of knee flexion and a decrease of patellar ligament tension with statistical significance (P<0.05) at 100 degrees, 120 degrees, 130 degrees, and 140 degrees of flexion using high-flex insert compared to traditional insert. Eliminating the impingement between extensor mechanism and implant in high knee flexion altered patellar tracking and reduced patellar ligament tension, which would facilitate high knee flexion.
2015-03-01
Through the use of a sophisticated modeling technique, investigators at the University of Cincinnati have found that the creation of a so-called "flex track" that includes beds that can be assigned to either high-acuity or Iow-acuity- patients has the potential to lower mean wait times for patients when it is i added to the traditional fast-track and high-acuity areas of a 50-bed ED that sees 85,000 patients per year. Investigators used discrete-event simulation to model the patient flow and characteristics of the ED at the University of Cincinnati Medical Center, and to test out various operational scenarios without disrupting real-world operations. The investigators concluded that patient wait times were lowest when three flex beds were appropriated from the 10-bed fast track area of the EDs. In light of the results, three flex rooms are being incorporated into a newly remodeled ED scheduled for completion laterthis spring. Investigators suggest the modeling technique could be useful to other EDs interested in optimizing their operational plans. Further, they suggest that ED administrators consider ways to introduce flexibility into departments that are now more rigidly divided between high- and low-acuity areas.
Tracking C. elegans and its neuromuscular activity using NemaFlex
NASA Astrophysics Data System (ADS)
van Bussel, Frank; Rahman, Mizanur; Hewitt, Jennifer; Blawzdziewicz, Jerzy; Driscoll, Monica; Szewczyk, Nathaniel; Vanapalli, Siva
Recently, a novel platform has been developed for studying the behavior and physical characteristics of the nematode C. elegans. This is NemaFlex, developed by the Vanapalli group at Texas Tech University to analyze movement and muscular strength of crawling C. elegans. NemaFlex is a microfluidic device consisting of an array of deformable PDMS pillars, with which the C. elegans interacts in the course of moving through the system. Deflection measurements then allow us to calculate the force exerted by the worm via Euler-Bernoulli beam theory. For the procedure to be fully automated a fairly sophisticated software analysis has to be developed in tandem with the physical device. In particular, the usefulness of the force calculations is highly dependent on the accuracy and volume of the deflection measurements, which would be prohibitively time-consuming if carried out by hand/eye. In order to correlate the force results with muscle activations the C. elegans itself has to be tracked simultaneously, and pillar deflections precisely associated with mechanical-contact on the worm's body. Here we will outline the data processing and analysis routines that have been implemented in order to automate the calculation of these forces and muscular activations.
Kinematic Adaptations of Forward And Backward Walking on Land and in Water
Cadenas-Sanchez, Cristina; Arellano, Raúl; Vanrenterghem, Jos; López-Contreras, Gracia
2015-01-01
The aim of this study was to compare sagittal plane lower limb kinematics during walking on land and submerged to the hip in water. Eight healthy adults (age 22.1 ± 1.1 years, body height 174.8 ± 7.1 cm, body mass 63.4 ± 6.2 kg) were asked to cover a distance of 10 m at comfortable speed with controlled step frequency, walking forward or backward. Sagittal plane lower limb kinematics were obtained from three dimensional video analysis to compare spatiotemporal gait parameters and joint angles at selected events using two-way repeated measures ANOVA. Key findings were a reduced walking speed, stride length, step length and a support phase in water, and step length asymmetry was higher compared to the land condition (p<0.05). At initial contact, knees and hips were more flexed during walking forward in water, whilst, ankles were more dorsiflexed during walking backward in water. At final stance, knees and ankles were more flexed during forward walking, whilst the hip was more flexed during backward walking. These results show how walking in water differs from walking on land, and provide valuable insights into the development and prescription of rehabilitation and training programs. PMID:26839602
Fuel Economy and Emissions of a Vehicle Equipped with an Aftermarket Flexible-Fuel Conversion Kit
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thomas, John F; Huff, Shean P; West, Brian H
2012-04-01
The U.S. Environmental Protection Agency (EPA) grants Certificates of Conformity for alternative fuel conversion systems and also offers other forms of premarket registration of conversion kits for use in vehicles more than two model years old. Use of alternative fuels such as ethanol, natural gas, and propane are encouraged by the Energy Policy Act of 1992. Several original equipment manufacturers (OEMs) produce emissions-certified vehicles capable of using alternative fuels, and several alternative fuel conversion system manufacturers produce EPA-approved conversion systems for a variety of alternative fuels and vehicle types. To date, only one manufacturer (Flex Fuel U.S.) has received EPAmore » certifications for ethanol fuel (E85) conversion kits. This report details an independent evaluation of a vehicle with a legal installation of a Flex Fuel U.S. conversion kit. A 2006 Dodge Charger was baseline tested with ethanol-free certification gasoline (E0) and E20 (gasoline with 20 vol % ethanol), converted to flex-fuel operation via installation of a Flex Box Smart Kit from Flex Fuel U.S., and retested with E0, E20, E50, and E81. Test cycles included the Federal Test Procedure (FTP or city cycle), the highway fuel economy test (HFET), and the US06 test (aggressive driving test). Averaged test results show that the vehicle was emissions compliant on E0 in the OEM condition (before conversion) and compliant on all test fuels after conversion. Average nitrogen oxide (NOx) emissions exceeded the Tier 2/Bin 5 intermediate life NO{sub X} standard with E20 fuel in the OEM condition due to two of three test results exceeding this standard [note that E20 is not a legal fuel for non-flexible-fuel vehicles (non-FFVs)]. In addition, one E0 test result before conversion and one E20 test result after conversion exceeded the NOX standard, although the average result in these two cases was below the standard. Emissions of ethanol and acetaldehyde increased with increasing ethanol, while nonmethane organic gas and CO emissions remained relatively unchanged for all fuels and cycles. Higher fraction ethanol blends appeared to decrease NO{sub X} emissions on the FTP and HFET (after conversion). As expected, fuel economy (miles per gallon) decreased with increasing ethanol content in all cases.« less
Evaluating the Large-Scale Environment of Extreme Events Using Reanalyses
NASA Astrophysics Data System (ADS)
Bosilovich, M. G.; Schubert, S. D.; Koster, R. D.; da Silva, A. M., Jr.; Eichmann, A.
2014-12-01
Extreme conditions and events have always been a long standing concern in weather forecasting and national security. While some evidence indicates extreme weather will increase in global change scenarios, extremes are often related to the large scale atmospheric circulation, but also occurring infrequently. Reanalyses assimilate substantial amounts of weather data and a primary strength of reanalysis data is the representation of the large-scale atmospheric environment. In this effort, we link the occurrences of extreme events or climate indicators to the underlying regional and global weather patterns. Now, with greater than 3o years of data, reanalyses can include multiple cases of extreme events, and thereby identify commonality among the weather to better characterize the large-scale to global environment linked to the indicator or extreme event. Since these features are certainly regionally dependent, and also, the indicators of climate are continually being developed, we outline various methods to analyze the reanalysis data and the development of tools to support regional evaluation of the data. Here, we provide some examples of both individual case studies and composite studies of similar events. For example, we will compare the large scale environment for Northeastern US extreme precipitation with that of highest mean precipitation seasons. Likewise, southerly winds can shown to be a major contributor to very warm days in the Northeast winter. While most of our development has involved NASA's MERRA reanalysis, we are also looking forward to MERRA-2 which includes several new features that greatly improve the representation of weather and climate, especially for the regions and sectors involved in the National Climate Assessment.
Moving in extreme environments: what's extreme and who decides?
Cotter, James David; Tipton, Michael J
2014-01-01
Humans work, rest and play in immensely varied extreme environments. The term 'extreme' typically refers to insufficiency or excess of one or more stressors, such as thermal energy or gravity. Individuals' behavioural and physiological capacity to endure and enjoy such environments varies immensely. Adverse effects of acute exposure to these environments are readily identifiable (e.g. heat stroke or bone fracture), whereas adverse effects of chronic exposure (e.g. stress fractures or osteoporosis) may be as important but much less discernable. Modern societies have increasingly sought to protect people from such stressors and, in that way, minimise their adverse effects. Regulations are thus established, and advice is provided on what is 'acceptable' exposure. Examples include work/rest cycles in the heat, hydration regimes, rates of ascent to and duration of stay at altitude and diving depth. While usually valuable and well intentioned, it is important to realise the breadth and importance of limitations associated with such guidelines. Regulations and advisories leave less room for self-determination, learning and perhaps adaptation. Regulations based on stress (e.g. work/rest cycles relative to WBGT) are more practical but less direct than those based on strain (e.g. core temperature), but even the latter can be substantively limited (e.g. by lack of criterion validation and allowance for behavioural regulation in the research on which they are based). Extreme Physiology & Medicine is publishing a series of reviews aimed at critically examining the issues involved with self- versus regulation-controlled human movement acutely and chronically in extreme environments. These papers, arising from a research symposium in 2013, are about the impact of people engaging in such environments and the effect of rules and guidelines on their safety, enjoyment, autonomy and productivity. The reviews will cover occupational heat stress, sporting heat stress, hydration, diving, extreme loading, chronic unloading and high altitude. Ramifications include factors such as health and safety, productivity, enjoyment and autonomy, acute and chronic protection and optimising adaptation.
Yang, Ji; Li, Wen-Rong; Lv, Feng-Hua; He, San-Gang; Tian, Shi-Lin; Peng, Wei-Feng; Sun, Ya-Wei; Zhao, Yong-Xin; Tu, Xiao-Long; Zhang, Min; Xie, Xing-Long; Wang, Yu-Tao; Li, Jin-Quan; Liu, Yong-Gang; Shen, Zhi-Qiang; Wang, Feng; Liu, Guang-Jian; Lu, Hong-Feng; Kantanen, Juha; Han, Jian-Lin; Li, Meng-Hua; Liu, Ming-Jun
2016-01-01
Global climate change has a significant effect on extreme environments and a profound influence on species survival. However, little is known of the genome-wide pattern of livestock adaptations to extreme environments over a short time frame following domestication. Sheep (Ovis aries) have become well adapted to a diverse range of agroecological zones, including certain extreme environments (e.g., plateaus and deserts), during their post-domestication (approximately 8–9 kya) migration and differentiation. Here, we generated whole-genome sequences from 77 native sheep, with an average effective sequencing depth of ∼5× for 75 samples and ∼42× for 2 samples. Comparative genomic analyses among sheep in contrasting environments, that is, plateau (>4,000 m above sea level) versus lowland (<100 m), high-altitude region (>1500 m) versus low-altitude region (<1300 m), desert (<10 mm average annual precipitation) versus highly humid region (>600 mm), and arid zone (<400 mm) versus humid zone (>400 mm), detected a novel set of candidate genes as well as pathways and GO categories that are putatively associated with hypoxia responses at high altitudes and water reabsorption in arid environments. In addition, candidate genes and GO terms functionally related to energy metabolism and body size variations were identified. This study offers novel insights into rapid genomic adaptations to extreme environments in sheep and other animals, and provides a valuable resource for future research on livestock breeding in response to climate change. PMID:27401233
NASA Astrophysics Data System (ADS)
Sutton, Akil K.
Hydrocarbon exploration, global navigation satellite systems, computed tomography, and aircraft avionics are just a few examples of applications that require system operation at an ambient temperature, pressure, or radiation level outside the range covered by military specifications. The electronics employed in these applications are known as "extreme environment electronics." On account of the increased cost resulting from both process modifications and the use of exotic substrate materials, only a handful of semiconductor foundries have specialized in the production of extreme environment electronics. Protection of these electronic systems in an extreme environment may be attained by encapsulating sensitive circuits in a controlled environment, which provides isolation from the hostile ambient, often at a significant cost and performance penalty. In a significant departure from this traditional approach, system designers have begun to use commercial off-the-shelf technology platforms with built in mitigation techniques for extreme environment applications. Such an approach simultaneously leverages the state of the art in technology performance with significant savings in project cost. Silicon-germanium is one such commercial technology platform that demonstrates potential for deployment into extreme environment applications as a result of its excellent performance at cryogenic temperatures, remarkable tolerance to radiation-induced degradation, and monolithic integration with silicon-based manufacturing. In this dissertation the radiation response of silicon-germanium technology is investigated, and novel transistor-level layout-based techniques are implemented to improve the radiation tolerance of HBT digital logic.
Muscular development and lean body weight in body builders and weight lifters.
Katch, V L; Katch, F I; Moffatt, R; Gittleson, M
1980-01-01
The extent of extreme muscular development in 39 males identified as body builders (N = 18), power weight lifters (N = 13), and Olympic weight lifters (N = 8) were studied. Body composition and anthropometric data, including calculations of pre-excess muscle body weight (scale weight minus excess muscle) were obtained. The lean body weight and percent fats of the subjects were: body builders = 74.6 kg, 9.3%; power weight lifters = 73.3 kg, 9.1%; and Olympic weight lifters = 68.2 kg, 10.8%. No group differences were present in frame size, percent fat, lean body weight, skinfolds, and diameter measurements. The only group differences were for the shoulders, chest, biceps relaxed and flexed, and forearm girths. In each case the body builders were larger. Calculations of excess muscle by the Behnke method revealed that the body builders had 15.6 kg excess muscle, power weight lifters 14.8 kg, and Olympic weight lifters 13.1 kg. Somatographic comparisons revealed only slight differences between the groups, while differences with reference man were substantial.
Axelsson, Charles; van Sebille, Erik
2017-11-15
The leakage of large plastic litter (macroplastics) into the ocean is a major environmental problem. A significant fraction of this leakage originates from coastal cities, particularly during extreme rainfall events. As coastal cities continue to grow, finding ways to reduce this macroplastic leakage is extremely pertinent. Here, we explore why and how coastal cities can reduce macroplastic leakages during extreme rainfall events. Using nine global cities as a basis, we establish that while cities actively create policies that reduce plastic leakages, more needs to be done. Nonetheless, these policies are economically, socially and environmentally cobeneficial to the city environment. While the lack of political engagement and economic concerns limit these policies, lacking social motivation and engagement is the largest limitation towards implementing policy. We recommend cities to incentivize citizen and municipal engagement with responsible usage of plastics, cleaning the environment and preparing for future extreme rainfall events. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.
NASA Technical Reports Server (NTRS)
Stough, Roger
2004-01-01
The purpose of this workshop was to survey existing health and safety policies as well as processes and practices for various extreme environments; to identify strengths and shortcomings of these processes; and to recommend parameters for inclusion in a generic approach to policy formulation, applicable to the broadest categories of extreme environments. It was anticipated that two additional workshops would follow. The November 7, 2003 workshop would be devoted to the evaluation of different model(s) and a concluding expert evaluation of the usefulness of the model using a policy formulation example. The final workshop was planned for March 2004.
An Automaton Rover for Extreme Environments: Rethinking an Approach to Surface Mobility
NASA Astrophysics Data System (ADS)
Sauder, J.; Hilgemman, E.; Stack, K.; Kawata, J.; Parness, A.; Johnson, M.
2017-11-01
An Automaton Rover for Extreme Environments (AREE) enables long duration in-situ mobility on the surface of Venus through a simplified design and robust mechanisms. The goal is to design a rover capable of operating for months on the surface of Venus.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 28 2011-07-01 2011-07-01 false What quantities of extremely hazardous substances trigger emergency planning requirements? 355.12 Section 355.12 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SUPERFUND, EMERGENCY PLANNING, AND COMMUNITY RIGHT-TO-KNOW PROGRAMS...
Semi-flexible gas-insulated transmission line using electric field stress shields
Cookson, Alan H.; Dale, Steinar J.; Bolin, Philip C.
1982-12-28
A gas-insulated transmission line includes an outer sheath, an inner conductor, an insulating gas electrically insulating the inner conductor from the outer sheath, and insulating supports insulatably supporting the inner conductor within the outer sheath. The inner conductor is provided with flexibility by use of main conductor sections which are joined together through a conductor hub section and flexible flexing elements. Stress shields are provided to control the electric field at the locations of the conductor hub sections where the insulating supports are contacting the inner conductor. The flexing elements and the stress shields may also be utilized in connection with a plug and socket arrangement for providing electrical connection between main conductor sections.
P80 SRM low torque flex-seal development - thermal and chemical modeling of molding process
NASA Astrophysics Data System (ADS)
Descamps, C.; Gautronneau, E.; Rousseau, G.; Daurat, M.
2009-09-01
The development of the flex-seal component of the P80 nozzle gave the opportunity to set up new design and manufacturing process methods. Due to the short development lead time required by VEGA program, the usual manufacturing iterative tests work flow, which is usually time consuming, had to be enhanced in order to use a more predictive approach. A newly refined rubber vulcanization description was built up and identified on laboratory samples. This chemical model was implemented in a thermal analysis code. The complete model successfully supports the manufacturing processes. These activities were conducted with the support of ESA/CNES Research & Technologies and DGA (General Delegation for Armament).
Yang, Ji; Li, Wen-Rong; Lv, Feng-Hua; He, San-Gang; Tian, Shi-Lin; Peng, Wei-Feng; Sun, Ya-Wei; Zhao, Yong-Xin; Tu, Xiao-Long; Zhang, Min; Xie, Xing-Long; Wang, Yu-Tao; Li, Jin-Quan; Liu, Yong-Gang; Shen, Zhi-Qiang; Wang, Feng; Liu, Guang-Jian; Lu, Hong-Feng; Kantanen, Juha; Han, Jian-Lin; Li, Meng-Hua; Liu, Ming-Jun
2016-10-01
Global climate change has a significant effect on extreme environments and a profound influence on species survival. However, little is known of the genome-wide pattern of livestock adaptations to extreme environments over a short time frame following domestication. Sheep (Ovis aries) have become well adapted to a diverse range of agroecological zones, including certain extreme environments (e.g., plateaus and deserts), during their post-domestication (approximately 8-9 kya) migration and differentiation. Here, we generated whole-genome sequences from 77 native sheep, with an average effective sequencing depth of ∼5× for 75 samples and ∼42× for 2 samples. Comparative genomic analyses among sheep in contrasting environments, that is, plateau (>4,000 m above sea level) versus lowland (<100 m), high-altitude region (>1500 m) versus low-altitude region (<1300 m), desert (<10 mm average annual precipitation) versus highly humid region (>600 mm), and arid zone (<400 mm) versus humid zone (>400 mm), detected a novel set of candidate genes as well as pathways and GO categories that are putatively associated with hypoxia responses at high altitudes and water reabsorption in arid environments. In addition, candidate genes and GO terms functionally related to energy metabolism and body size variations were identified. This study offers novel insights into rapid genomic adaptations to extreme environments in sheep and other animals, and provides a valuable resource for future research on livestock breeding in response to climate change. © The Author 2016. Published by Oxford University Press on behalf of the Society for Molecular Biology and Evolution.
TransFormers for Ensuring Long-Term Operations in Lunar Extreme Environments
NASA Technical Reports Server (NTRS)
Mantovani, J. G.; Stoica, A.; Alkalai, L.; Wilcox, B.; Quadrelli, M.
2016-01-01
"Surviving Extreme Space Environments" (EE) is one of NASA's Space Technology Grand Challenges. Power generation and thermal control are the key survival ingredients that allow a robotic explorer to cope with the EE using resources available to it, for example, by harvesting the local solar energy or by utilizing an onboard radioisotope thermoelectric generator (RTG). TransFormers (TFs) are a new technology concept designed to transform a localized area within a harsh extreme environment into a survivable micro-environment by projecting energy to the precise location where robots or humans operate. For example, TFs placed at a location on the rim of Shackleton Crater, which is illuminated by solar radiation for most of the year, would be able to reflect solar energy onto robots operating in the dark cold crater. TFs utilize a shape transformation mechanism to un-fold from a compact volume to a large reflective surface, and to control how much-and where-the energy is projected, and by adjusting for the changing position of the sun. TFs would enable in-situ resource utilization (ISRU) activities within locations of high interest that would normally be unreachable because of their extreme environment
[The acclimatization to extreme environments and its physiological mechanisms].
Wang, Hai; Liu, Wei; Yang, Dan-Feng; Zhao, Xiao-Ling; Long, Chao-Liang; Yin, Zhao-Yun; Liu, Jia-Ying
2012-11-01
Acclimatization is a process of biological adaptation when exposed to environmental factors such as hypoxia, cold and heat for prolonged periods of time, where non-genetical variations play a role in allowing subjects to tolerate hypoxic, cold or hot environments. This review focuses on the characteristics and mechanisms of acclimatization found through major research advances by our institute. First, the mechanisms underlying the acclimatization to extreme environments are complex. In our investigations, the physiological changes of multiple systems including the nervous, circulatory, respiratory, and hemopoietic system were demonstrated when the acclimatization to hypoxia was developed, and the underlying significance of hypoxia-inducible factor-1 (HIF-1) was investigated. Second, it is suggested that the development of acclimatization to extreme environments is complicated. Hypoxia and cold coexist at high altitude. Our investigations revealed the characteristics of negative cross-relationship in the acclimatization to hypoxia and cold. And third, it is interesting for us to understand that acclimatization to extreme environments is transferable among individuals, and the characteristics of heat acclimatization-inducing factor (HAlF) were presented. The above findings will provide a theoretical guidance for protective operations and help to establish a solid foundation for future research related to acclimatization.
NASA Technical Reports Server (NTRS)
Venkatapathy, Ethiraj
2016-01-01
This invited talk will give a brief overview of the integrated heat-shield system design that requires seams and the extreme environment conditions that HEEET should be demonstrated to be capable of thermal performance without fail. We have tested HEEET across many different facilities and at conditions that are extreme. The presentation will highlight the performance of both the acreage as well as integrated seam at these conditions. The Invite talks are 10 min and hence this presentation will be short.
Extreme Environments Capabilities at Glenn Research Center
NASA Technical Reports Server (NTRS)
Balcerski, Jeffrey; Kremic, Tibor; Arnett, Lori; Vento, Dan; Nakley, Leah
2016-01-01
The NASA Glenn Research Center has several facilities that can provide testing for extreme evironments of interest to the New Frontiers community. This includes the Glenn Extreme Enivironments Rig (GEER) which can duplicate the atmospheric chemistry and conditions for the Venus surface or any other planet with a hot environment. GRC also has several cryogenic facilities which have the capability to run with hydrogen atmospheres, hydrocarbon atmosphere, CO2 based atmospheres or nitrogen atmospheres. The cryogenic facilities have the capability to emulate Titan lakes.
Testing postural control among various osteoporotic patient groups: a literature review.
de Groot, Maartje H; van der Jagt-Willems, Hanna C; van Campen, Jos P C M; Lems, Willem F; Lamoth, Claudine J C
2012-10-01
Osteoporosis can cause vertebral fractures, which might lead to a flexed posture, impaired postural control and consequently increased fall risk. Therefore, the aim of the present review was to examine whether postural control of patients with osteoporosis, vertebral fractures, thoracic kyphosis and flexed posture is affected. Furthermore, instruments measuring postural control were evaluated and examined for sensitivity and easy clinical use. Until February 2011, electronic databases were systematically searched for cross-sectional studies. Methodological quality was assessed with a modified Downs & Black scale. Of the 518 found studies, 18 studies were included. Postural control was generally affected for patients with vertebral fractures, thoracic kyphosis and flexed posture. Patients with osteoporosis had impaired postural control when assessed with computerized instruments. Easy performance-based tests did not show any impairments. There is evidence for an impaired postural control in all patient groups included. Impaired postural control is an important risk factor for falls. Functional performance tests are not sensitive and specific enough to detect affected postural control in patients with osteoporosis. To detect impaired postural control among osteoporotic patients and to obtain more insight into the underlying mechanisms of postural control, computerized instruments are recommended, such as easy-to-use ambulant motion-sensing (accelerometry) technology. © 2012 Japan Geriatrics Society.
Kobashi, Hidenaga; Kamiya, Kazutaka; Ali, Mohamed A.; Igarashi, Akihito; Elewa, Mohamed Ehab M.; Shimizu, Kimiya
2015-01-01
Purpose To compare postoperative astigmatic correction between femtosecond lenticule extraction (FLEx) and small-incision lenticule extraction (SMILE) in eyes with myopic astigmatism. Methods We examined 26 eyes of 26 patients undergoing FLEx and 26 eyes of 26 patients undergoing SMILE to correct myopic astigmatism (manifest astigmatism of 1 diopter (D) or more). Visual acuity, cylindrical refraction, the predictability of the astigmatic correction, and the astigmatic vector components using Alpin’s method, were compared between the two groups 3 months postoperatively. Results We found no statistically significant difference in manifest cylindrical refraction (p=0.74) or in the percentage of eyes within ± 0.50 D of their refraction (p=0.47) after the two surgical procedures. Moreover, no statistically significant difference was detected between the groups in astigmatic vector components, namely, surgically induced astigmatism (0.80), target induced astigmatism (p=0.87), astigmatic correction index (p=0.77), angle of error (p=0.24), difference vector (p=0.76), index of success (p=0.91), flattening effect (p=0.79), and flattening index (p=0.84). Conclusions Both FLEx and SMILE procedures are essentially equivalent in correcting myopic astigmatism using vector analysis, suggesting that the lifting or non-lifting of the flap does not significantly affect astigmatic outcomes after these surgical procedures. PMID:25849381
Cost Savings for Manufacturing Lithium Batteries in a Flexible Plant
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nelson, Paul A.; Ahmed, Shabbir; Gallagher, Kevin G.
2015-06-01
The flexible plant postulated in this study would produces types of batteries for electric-drive vehicles of the types hybrid (HEV), 10-mile range and 40-mile range plug-in hybrids (PHEV) and a 150-mile range battery-electric (EV). The annual production rate of the plant is 235,000 per year (30,000 EV batteries and 100,000 HEV batteries). The unit cost savings as calculated with the Argonne BatPaC model for this flex plant vs. dedicated plants range from 8% for the EV battery packs to 23% for the HEV packs including the battery management systems (BMS). The investment cost savings are even larger, ranging from 21%more » for EVs to 43% for HEVs. The costs of the 1.0-kWh HEV batteries are projected to approach $710 per unit and that of the EV batteries $228 per kWh with the most favorable cell chemistries and including the BMS. The best single indicator of the cost of producing lithium-manganate spinel/graphite batteries in a flex plant is the total cell area of the battery. For the four batteries studied, the price range is $20-24 per m2 of cell area including the cost of the BMS, averaging $21 per m2 for the entire flex plant.« less
Reinforced Electrode Architecture for a Flexible Battery with Paperlike Characteristics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gaikwad, AM; Chu, HN; Qeraj, R
2013-02-10
Compliant energy storage has not kept pace with flexible electronics. Herein we demonstrate a technique to reinforce arbitrary battery electrodes by supporting them with mechanically tough, low-cost fibrous membranes, which also serve as the separator. The membranes were laminated to form a full cell, and this stacked membrane reinforcement bears the loads during flexing. This technique was used to make a high energy density, nontoxic Zn-MnO2 battery with printed current collectors. The Zn and MnO2 electrodes were prepared by using a solution-based embedding process. The cell had a nominal potential of 1.5 V and an effective capacity of approximately 3more » mA h cm(-2). We investigated the effect of bending and fatigue on the electrochemical performance and mechanical integrity of the battery. The battery was able to maintain its capacity even after 1000 flex cycles to a bend radius of 2.54 cm. The battery showed an improvement in discharge capacity (ca. 10%) if the MnO2 electrode was flexed to tension as a result of the improvement of particle-to-particle contact. In a demonstration, the flexible battery was used to power a light-emitting diode display integrated with a strain sensor and microcontroller.« less
Gattinger, Norbert; Moessnang, Georg; Gleich, Bernhard
2012-07-01
Transcranial magnetic stimulation (TMS) is able to noninvasively excite neuronal populations due to brief magnetic field pulses. The efficiency and the characteristics of stimulation pulse shapes influence the physiological effect of TMS. However, commercial devices allow only a minimum of control of different pulse shapes. Basically, just sinusoidal and monophasic pulse shapes with fixed pulse widths are available. Only few research groups work on TMS devices with controllable pulse parameters such as pulse shape or pulse width. We describe a novel TMS device with a full-bridge circuit topology incorporating four insulated-gate bipolar transistor (IGBT) modules and one energy storage capacitor to generate arbitrary waveforms. This flexible TMS (flexTMS ) device can generate magnetic pulses which can be adjusted with respect to pulse width, polarity, and intensity. Furthermore, the equipment allows us to set paired pulses with a variable interstimulus interval (ISI) from 0 to 20 ms with a step size of 10 μs. All user-defined pulses can be applied continually with repetition rates up to 30 pulses per second (pps) or, respectively, up to 100 pps in theta burst mode. Offering this variety of flexibility, flexTMS will allow the enhancement of existing TMS paradigms and novel research applications.
Nassif, Jeffrey M; Pietrzak, William S
2015-01-01
While it is generally recognized that anatomical differences exist between the male and female knee, the literature generally refutes the clinical need for gender-specific total knee prostheses. It has been found that standard, unisex knees perform as well, or better, in women than men. Recently, high-flex knees have become available that mechanically accommodate increased flexion yet no studies have directly compared the outcomes of these devices in men and women to see if gender-based differences exist. We retrospectively compared the performance of the high-flex Vanguard knee (Biomet, Warsaw, IN) in 716 male and 1,069 female knees. Kaplan-Meier survivorship was 98.5% at 5.6-5.7 years for both genders. After 2 years, mean improvements in Knee Society Knee and Function scores for men and women (50.9 versus 46.3; 26.5 versus 23.1) and corresponding SF-12 Mental and Physical scores (0.2 versus 2.2; 13.7 versus 12.2) were similar with differences not clinically relevant. Postoperative motion gains as a function of preoperative motion level were virtually identical in men and women. This further confirms the suitability of unisex total knee prostheses for both men and women.
Bai, Ling; Zhang, Jin; Chen, Ling; Ma, Ting; Liang, Hou-Cheng
2015-01-01
AIM To compare posterior capsule opacification (PCO) degree and visual functions after phacoemulsification in eyes implanted with 360-degree square edge hydrophilic acrylic intraocular lens (IOL) (570C C-flex, Rayner) and sharp edge hydrophobic acrylic IOL (Sensar AR40e, AMO) in diabetic patients. METHODS Sixty diabetic patients underwent uneventful phacoemulsification and randomly implanted one of the two IOLs. The PCO value was measured by retroillumination photographs and Evaluation of Posterior Capsule Opacification (EPCO) 2000 image-analysis software at 1, 6, 12, and 24mo after surgery. Visual acuity, and contrast sensitivity in photopic and mesopic conditions were also examined at each follow up time point. The incidence of eye that required Nd:YAG laser posterior capsulotomy were also compared. RESULTS There was not any statistically significant difference in PCO scores between Rayner C-flex 570C group and Sensar AR40e group at each follow up time point. Visual acuity, Nd:YAG capsulotomy incidence and contrast sensitivity also had no significant difference during the 24mo follow-up. CONCLUSION For diabetic patients, Rayner 570C C-flex and Sensar AR40e IOLs are same effective for prevent PCO. The 360-degree square edge design maybe is a good alternative technique to improve PCO prevention. PMID:26309870
Masai, Kyohei; Sasada, Shinji; Izumo, Takehiro; Taniyama, Tomoko; Nakamura, Yukiko; Chavez, Christine; Sakurai, Hiroyuki; Tsuta, Koji; Tsuchida, Takaaki
2013-10-01
Desmoplastic malignant mesothelioma (DMM) is a rare subtype of malignant pleural mesothelioma (MPM) and is often difficult to distinguish from pleural fibrosis and reactive mesothelial hyperplasia, especially if the biopsy samples are small. We performed full-thickness pleural biopsy on a lesion suspected to be DMM using an insulated-tip diathermic knife-2 (IT knife-2) during flex-rigid pleuroscopy. IT knife-2 is a novel electrosurgical device for endoscopic submucosal dissection in the early gastrointestinal cancer. It consists of a needle knife with 3 short blades at the distal end attached to an insulated ceramic tip. A 54-year-old man presenting with chest wall mass and thickened pleura, in whom a computed tomography-guided percutaneous needle aspiration had remained negative, underwent flex-rigid pleuroscopy for definitive diagnosis. While applying electric current, we used the IT knife-2 to incise the pleura in a circular shape just above the endothoracic fascia. The incised pleura was removed by forceps and examined pathologically. The microscopic examination was compatible with DMM. We discovered that pleuroscopic punch biopsy using IT knife-2 can diagnose DMM. Use of IT knife-2 during flex-rigid pleuroscopy can obtain sufficient samples from densely thickened pleura, which is difficult to diagnose with small biopsies.
Bai, Ling; Zhang, Jin; Chen, Ling; Ma, Ting; Liang, Hou-Cheng
2015-01-01
To compare posterior capsule opacification (PCO) degree and visual functions after phacoemulsification in eyes implanted with 360-degree square edge hydrophilic acrylic intraocular lens (IOL) (570C C-flex, Rayner) and sharp edge hydrophobic acrylic IOL (Sensar AR40e, AMO) in diabetic patients. Sixty diabetic patients underwent uneventful phacoemulsification and randomly implanted one of the two IOLs. The PCO value was measured by retroillumination photographs and Evaluation of Posterior Capsule Opacification (EPCO) 2000 image-analysis software at 1, 6, 12, and 24mo after surgery. Visual acuity, and contrast sensitivity in photopic and mesopic conditions were also examined at each follow up time point. The incidence of eye that required Nd:YAG laser posterior capsulotomy were also compared. There was not any statistically significant difference in PCO scores between Rayner C-flex 570C group and Sensar AR40e group at each follow up time point. Visual acuity, Nd:YAG capsulotomy incidence and contrast sensitivity also had no significant difference during the 24mo follow-up. For diabetic patients, Rayner 570C C-flex and Sensar AR40e IOLs are same effective for prevent PCO. The 360-degree square edge design maybe is a good alternative technique to improve PCO prevention.
Validating Efficacy of Shea Nut Oil Extract in Knee Osteoarthritis Patients
Lo, Sui-Foon; Wang, Yu-Chia; Chou, Tzu-Yi; Chang, Kang-Ming
2013-01-01
Objectives. To examine and investigate the efficacy of shea nut oil extract (SheaFlex75) in relation to knee osteoarthritis (OA). Methods. Thirty-three patients (age 63.6 ± 5.8 years) with knee OA were recruited. Real-time ultrasound imaging and surface electromyography were used to objectively assess the morphological changes and the activity of vastus medialis oblique (VMO) muscles during a 16-week intervention of SheaFlex75. The intraclass correlation coefficient (ICC) was calculated to examine the reliability of the interscans. A paired-sample t-test was used to compare the findings in different stages. The Spearman's rank correlation coefficient was used to examine the relationship between the relevant variables of OA and percentage of thickness change of VMO at different contraction levels. Results. The baseline findings showed strong correlation, suggesting that the reliability of interscans at pretest was high. The ability to contract the muscles of the knee to a 30% contraction level showed significant change between the baseline and after 16-week testing, both in terms of morphological changes and muscle activity. Pain scale reported a significant decrease at the 16th week. Conclusion. The results suggest that SheaFlex75 can relieve the symptoms of knee OA and can result in improvement of muscle control of the knee. PMID:24454485
The influences of sex and posture on joint energetics during drop landings.
Norcross, M F; Shultz, S J; Weinhold, P S; Lewek, M D; Padua, D A; Blackburn, J T
2015-04-01
Previous observations suggest that females utilize a more erect initial landing posture than males with sex differences in landing posture possibly related to sex-specific energy absorption (EA) strategies. However, sex-specific EA strategies have only been observed when accompanied by sex differences in initial landing posture. This study (a) investigated the potential existence of sex-specific EA strategies; and (b) determined the influences of sex and initial landing posture on the biomechanical determinants of EA. The landing biomechanics of 80 subjects were recorded during drop landings in Preferred, Flexed, and Erect conditions. No sex differences in joint EA were identified after controlling for initial landing posture. Males and females exhibited greater ankle EA during Erect vs Flexed landings with this increase driven by 12% greater ankle velocity, but no change in ankle extensor moment. No differences in hip and knee EA were observed between conditions. However, to achieve similar knee EA, subjects used 7% greater mean knee extensor moment but 9% less knee angular velocity during Flexed landings. The results suggest that sex-specific EA strategies do not exist, and that the magnitude of knee joint EA can be maintained by modulating the relative contributions of joint moment and angular velocity to EA. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Constructing and Screening a Metagenomic Library of a Cold and Alkaline Extreme Environment.
Glaring, Mikkel A; Vester, Jan K; Stougaard, Peter
2017-01-01
Natural cold or alkaline environments are common on Earth. A rare combination of these two extremes is found in the permanently cold (less than 6 °C) and alkaline (pH above 10) ikaite columns in the Ikka Fjord in Southern Greenland. Bioprospecting efforts have established the ikaite columns as a source of bacteria and enzymes adapted to these conditions. They have also highlighted the limitations of cultivation-based methods in this extreme environment and metagenomic approaches may provide access to novel extremophilic enzymes from the uncultured majority of bacteria. Here, we describe the construction and screening of a metagenomic library of the prokaryotic community inhabiting the ikaite columns.
Evaluating teams in extreme environments: from issues to answers.
Bishop, Sheryl L
2004-07-01
The challenge to effectively evaluating teams in extreme environments necessarily involves a wide range of physiological, psychological, and psychosocial factors. The high reliance on technology, the growing frequency of multinational and multicultural teams, and the demand for longer duration missions all further compound the complexity of the problem. The primary goal is the insurance of human health and well-being with expectations that such priorities will naturally lead to improved chances for performance and mission success. This paper provides an overview of some of the most salient immediate challenges for selecting, training, and supporting teams in extreme environments, gives exemplars of research findings concerning these challenges, and discusses the need for future research.
McGovern, Donna L; Mosier, Philip D; Roth, Bryan L; Westkaemper, Richard B
2010-04-01
The highly potent and kappa-opioid (KOP) receptor-selective hallucinogen Salvinorin A and selected analogs have been analyzed using the 3D quantitative structure-affinity relationship technique Comparative Molecular Field Analysis (CoMFA) in an effort to derive a statistically significant and predictive model of salvinorin affinity at the KOP receptor and to provide additional statistical support for the validity of previously proposed structure-based interaction models. Two CoMFA models of Salvinorin A analogs substituted at the C-2 position are presented. Separate models were developed based on the radioligand used in the kappa-opioid binding assay, [(3)H]diprenorphine or [(125)I]6 beta-iodo-3,14-dihydroxy-17-cyclopropylmethyl-4,5 alpha-epoxymorphinan ([(125)I]IOXY). For each dataset, three methods of alignment were employed: a receptor-docked alignment derived from the structure-based docking algorithm GOLD, another from the ligand-based alignment algorithm FlexS, and a rigid realignment of the poses from the receptor-docked alignment. The receptor-docked alignment produced statistically superior results compared to either the FlexS alignment or the realignment in both datasets. The [(125)I]IOXY set (Model 1) and [(3)H]diprenorphine set (Model 2) gave q(2) values of 0.592 and 0.620, respectively, using the receptor-docked alignment, and both models produced similar CoMFA contour maps that reflected the stereoelectronic features of the receptor model from which they were derived. Each model gave significantly predictive CoMFA statistics (Model 1 PSET r(2)=0.833; Model 2 PSET r(2)=0.813). Based on the CoMFA contour maps, a binding mode was proposed for amine-containing Salvinorin A analogs that provides a rationale for the observation that the beta-epimers (R-configuration) of protonated amines at the C-2 position have a higher affinity than the corresponding alpha-epimers (S-configuration). (c) 2010. Published by Elsevier Inc.
Dobran, Mauro; Esposito, Domenico Paolo; Gladi, Maurizio; Scerrati, Massimo; Iacoangeli, Maurizio
2018-01-01
Study Design Retrospective study with long-term follow-up. Purpose To evaluate the long-term incidence of adjacent segment degeneration (ASD) and clinical outcomes in a consecutive series of patients who underwent spinal decompression associated with dynamic or hybrid stabilization with a Flex+TM stabilization system (SpineVision, Antony, France) for lumbar spinal stenosis. Overview of Literature The incidence of ASD and clinical outcomes following dynamic or hybrid stabilization with the Flex+TM system used for lumbar spinal stenosis have not been well investigated. Methods Twenty-one patients with lumbar stenosis and probable post-decompressive spinal instability underwent decompressive laminectomy followed by spinal stabilization using the Flex+TM stabilization system. The indication for a mono-level dynamic stabilization was a preoperative magnetic resonance imaging (MRI) demonstrating evidence of severe disc disease associated with severe spinal stenosis. The hybrid stabilization (rigid-dynamic) system was used for multilevel laminectomies with associated initial degenerative scoliosis, first-grade spondylolisthesis, or rostral pathology. Results The improvement in Visual Analog Scale and Oswestry Disability Index scores at follow-up were statistically significant (p<0.0001 and p<0.0001, respectively). At the 5–8-year follow-up, clinical examination, MRI, and X-ray findings showed an ASD complication with pain and disability in one of 21 patients. The clinical outcomes were similar in patients treated with dynamic or hybrid fixation. Conclusions Patients treated with laminectomy and Flex+TM stabilization presented a satisfactory clinical outcome after 5–8 years of follow-up, and ASD incidence in our series was 4.76% (one patient out of 21). We are aware that this is a small series, but our long-term follow-up may be sufficient to contribute to the expanding body of literature on the development of symptomatic ASD associated with dynamic or hybrid fixation. PMID:29713407
Comparison of small diameter stone baskets in an in vitro caliceal and ureteral model.
Korman, Emily; Hendlin, Kari; Chotikawanich, Ekkarin; Monga, Manoj
2011-01-01
Three small diameter (<1.5F) stone baskets have recently been introduced. Our objective was to evaluate the stone capture rate of these baskets in an in vitro ureteral model and an in vitro caliceal model using novice, resident, and expert operators. Sacred Heart Medical Halo™ (1.5F), Cook N-Circle(®) Nitinol Tipless Stone Extractor (1.5F), and Boston Scientific OptiFlex(®) (1.3F) stone baskets were tested in an in vitro ureteral and a caliceal model by three novices, three residents, and three experts. The caliceal model consisted of a 7-cm length of 10-mm O.D. plastic tubing with a convex base. Each operator was timed during removal of a 3-mm calculus from each model with three repetitions for each basket. Data were analyzed by analysis of variance single factor tests and t tests assuming unequal variances. In the ureteral model, the Halo had the fastest average rate of stone extraction for experts and novices (0:02 ± 0:01 and 0:08 ± 0:04 min, respectively), as well as the overall fastest average stone extraction rate (0:08 ± 0:06 min). No statistical significant differences in extraction times between baskets were identified in the resident group. In the novice group, the Halo stone extraction rate was significantly faster than the OptiFlex (P=0.029). In the expert group, the OptiFlex had statistically significant slower average extraction rates compared with the Halo (P=0.005) and the N-Circle (P=0.017). In the caliceal model, no statistically significant differences were noted. While no significant differences were noted in extraction times for the caliceal model, the extraction times for the ureteral model were slowest with the OptiFlex basket. Other variables important in selection of the appropriate basket include operator preference, clinical setting, and cost.
Marra, Marco A; Strzelczak, Marta; Heesterbeek, Petra J C; van de Groes, Sebastiaan A W; Janssen, Dennis; Koopman, Bart F J M; Verdonschot, Nico; Wymenga, Ate B
2018-03-20
When downsizing the femoral component to prevent mediolateral overhang, notching of the anterior femoral cortex may occur, which could be solved by flexing the femoral component. In this study, we investigated the effect of flexion of the femoral component on patellar tendon moment arm, patellofemoral forces and kinematics in posterior-referencing CR-TKA. Our hypothesis was that flexion of the femoral component increases the patellar tendon moment arm, reduces the patellofemoral forces and provides stable kinematics. A validated musculoskeletal model of CR-TKA was used. The flexion of the femoral component was increased in four steps (0°, 3°, 6°, 9°) using posterior referencing, and different alignments were analysed in combination with three implant sizes (3, 4, 5). A chair-rising trial was analysed using the model, while simultaneously estimating quadriceps muscle force, patellofemoral contact force, tibiofemoral and patellofemoral kinematics. Compared to the reference case (size 4 and 0° flexion), for every 3° of increase in flexion of the femoral component the patellar tendon moment arm increased by 1% at knee extension. The peak quadriceps muscle force and patellofemoral contact force decreased by 2%, the patella shifted 0.8 mm more anteriorly and the remaining kinematics remained stable, with knee flexion. With the smaller size, the patellar tendon moment arm decreased by 6%, the quadriceps muscle force and patellofemoral contact force increased by 8 and 12%, and the patellar shifted 5 mm more posteriorly. Opposite trends were found with the bigger size. Flexing the femoral component with posterior referencing reduced the patellofemoral contact forces during a simulated chair-rising trial with a patient-specific musculoskeletal model of CR-TKA. There seems to be little risk when flexing and downsizing the femoral component, compared to when using a bigger size and neutral alignment. These findings provide relevant information to surgeons who wish to prevent anterior notching when downsizing the femoral component.
Gudiksen, Niels; Hofstätter, Thibaud; Rønn, Birgitte B; Sparre, Thomas
2017-10-01
FlexTouch® (Novo Nordisk A/S, Bagsvaerd, Denmark) is a pen-injector with a torque spring mechanism requiring a low activation force. This laboratory-based study compared the activation force of FlexTouch during the injection of insulin with different needles and at temperature conditions within the range at which the device is recommended for use. Using a tensile tester, activation force was measured at maximum dose settings for insulin detemir (100 U/mL) and insulin degludec (100 and 200 U/mL) at standard (23°C ± 5°C), cool (5°C ± 3°C), and warm (30°C ± 2°C) conditions. Activation force was measured with two 32-gauge needles differing in internal diameter at standard conditions. At standard, cool, and warm conditions, estimated mean activation forces with 95% confidence interval were 5.71 newtons (N) (5.63-5.79), 5.94 N (5.83-6.06), and 5.69 N (5.58-5.80) with insulin detemir, 5.53 N (5.45-5.62), 5.56 N (5.44-5.67), and 5.33 N (5.22-5.44) with 100 U/mL insulin degludec, and 5.53 N (5.45-5.61), 5.83 N (5.71-5.94), and 5.56 N (5.45-5.68) with 200 U/mL insulin degludec, respectively. Mean activation forces were observed to be low with very small variability between measurements; however, the differences between insulins and temperature conditions were statistically significant. The activation force required by FlexTouch remained low across all situations tested. The differences between activation force needed with different insulins and temperature conditions were small and unlikely to be clinically meaningful.
Niki, Yasuo; Takeda, Yuki; Harato, Kengo; Suda, Yasunori
2015-11-01
Achievement of very deep knee flexion after total knee arthroplasty (TKA) can play a critical role in the satisfaction of patients who demand a floor-sitting lifestyle and engage in high-flexion daily activities (e.g., seiza-sitting). Seiza-sitting is characterized by the knees flexed >145º and feet turned sole upwards underneath the buttocks with the tibia internally rotated. The present study investigated factors affecting the achievement of seiza-sitting after TKA using posterior-stabilized total knee prosthesis with high-flex knee design. Subjects comprised 32 patients who underwent TKA with high-flex knee prosthesis and achieved seiza-sitting (knee flexion >145º) postoperatively. Another 32 patients served as controls who were capable of knee flexion >145º preoperatively, but failed to achieve seiza-sitting postoperatively. Accuracy of femoral and tibial component positions was assessed in terms of deviation from the ideal position using a two-dimensional to three-dimensional matching technique. Accuracies of the component position, posterior condylar offset ratio and intraoperative gap length were compared between the two groups. The proportion of patients with >3º internally rotated tibial component was significantly higher in patients who failed at seiza-sitting (41 %) than among patients who achieved it (13 %, p = 0.021). Comparison of intraoperative gap length between patient groups revealed that gap length at 135º flexion was significantly larger in patients who achieved seiza-sitting (4.2 ± 0.4 mm) than in patients who failed at it (2.7 ± 0.4 mm, p = 0.007). Conversely, no significant differences in gap inclination were seen between the groups. From the perspective of surgical factors, accurate implant positioning, particularly rotational alignment of the tibial component, and maintenance of a sufficient joint gap at 135º flexion appear to represent critical factors for achieving >145º of deep knee flexion after TKA.
Variation in functional pelvic tilt in patients undergoing total hip arthroplasty.
Pierrepont, J; Hawdon, G; Miles, B P; Connor, B O'; Baré, J; Walter, L R; Marel, E; Solomon, M; McMahon, S; Shimmin, A J
2017-02-01
The pelvis rotates in the sagittal plane during daily activities. These rotations have a direct effect on the functional orientation of the acetabulum. The aim of this study was to quantify changes in pelvic tilt between different functional positions. Pre-operatively, pelvic tilt was measured in 1517 patients undergoing total hip arthroplasty (THA) in three functional positions - supine, standing and flexed seated (the moment when patients initiate rising from a seated position). Supine pelvic tilt was measured from CT scans, standing and flexed seated pelvic tilts were measured from standardised lateral radiographs. Anterior pelvic tilt was assigned a positive value. The mean pelvic tilt was 4.2° (-20.5° to 24.5°), -1.3° (-30.2° to 27.9°) and 0.6° (-42.0° to 41.3°) in the three positions, respectively. The mean sagittal pelvic rotation from supine to standing was -5.5° (-21.8° to 8.4°), from supine to flexed seated was -3.7° (-48.3° to 38.6°) and from standing to flexed seated was 1.8° (-51.8° to 39.5°). In 259 patients (17%), the extent of sagittal pelvic rotation could lead to functional malorientation of the acetabular component. Factoring in an intra-operative delivery error of ± 5° extends this risk to 51% of patients. Planning and measurement of the intended position of the acetabular component in the supine position may fail to predict clinically significant changes in its orientation during functional activities, as a consequence of individual pelvic kinematics. Optimal orientation is patient-specific and requires an evaluation of functional pelvic tilt pre-operatively. Cite this article: Bone Joint J 2017;99-B:184-91. ©2017 The British Editorial Society of Bone & Joint Surgery.
Zhang, Yu; Liu, Jun; Tian, Meng-qiang; Cheng, Yu; Tian, Zheng-wei; Sun, Zhen-hui; Ma, Xin-long
2010-05-15
To determine the effect of the posterior condylar offset (PCO) on intra- and post-operative knee flexion after total knee arthroplasty (TKA) using a high-flex posterior-stabilized (PS) fixed-bearing prosthesis and to discuss it's importance in femoral prosthesis design. The clinical and radiographic materials of 100 consecutive patients (100 knees) were prospectively studied, including 50 men and 50 women, who had undergone primary NexGen LPS-Flex TKAs for end-stage osteoarthritis. All operations were performed by a single surgeon using the same operative technique between March 2005 and October 2006. Pearson's regression analysis was used to assess the relationship between the difference in the pre- and post-operative PCO on true lateral radiographs and the change in knee range of flexion (ROF) under non-weight-bearing conditions. The decrease of the corrected PCO was (3.4 ± 3.3) mm compared with the preoperative value, the restoration of PCO was better in male than female [female (-5.4 ± 3.1) mm vs. male (-1.5 ± 2.0) mm, P < 0.05]. The difference in the corrected PCO after PS TKA demonstrated significantly correlated with the change in 2 years postoperative ROF in male and female, respectively (P < 0.05). While no statistically correlation was observed in the overall group (P > 0.05). Intraoperatively, the difference in the corrected PCO was significantly correlated with the change in ROF in male, female, and the overall group, respectively (P < 0.05). Restoration of PCO plays an important role in the optimization of knee flexion after high-flex PS TKA. Femoral components based on Caucasian anatomic characteristics could not match the native anatomy of distal femurs of Chinese population especially female Chinese. Rotated resection of distal femur with anterior referencing technique usually leads to a decreased PCO and therefore reduces maximal obtainable flexion. Sexual dimorphism in humans and anatomic variations in various ethnic groups should be seriously considered in total knee prosthesis design.
Jenkins, Wendy; Souza, Sonia; Ward, Marilyn; Defenbaugh, Jodi; Milleman, Kimberly R; Milleman, Jeffery L
2017-03-01
To assess the effect of the Philips Sonicare FlexCare Platinum with Premium plaque control brush head on gingival inflammation, bleeding, and supragingival plaque reduction following a six-week period of home use compared to a manual toothbrush. This was a randomized, single-blind, parallel-design clinical trial. Subjects included in the study were routine manual toothbrush users who were generally healthy non-smokers, aged 18-65 years, with mild to moderate gingivitis. Subjects with advanced periodontal disease, excessive gingival recession, and heavy deposits of calculus or rampant decay were excluded from the study. Eligible participants were dispensed either Philips Sonicare FlexCare Platinum with Premium plaque control brush head (PC), or an ADA Reference manual toothbrush (MTB) for twice-daily home oral hygiene procedures for six weeks. Efficacy measures included the Lobene and Soparker Modification of Quigley and Hein Plaque Index (MPI), the Modified Gingival Index (MGI), and Gingival Bleeding Index (GBI). Safety was evaluated by oral examination and subject report. Efficacy and safety were assessed at Baseline, and at two and six weeks following product home use. Of 154 subjects randomized, 143 subjects completed the study. For the primary endpoint, MGI at Week 2, statistically significantly larger reductions in MGI were observed for PC versus MTB, p < 0.0001. The adjusted mean reduction and standard error estimates (SE) for MGI, expressed as percent reduction versus Baseline to Week 2, were 41.73% (2.00%) for PC and 7.38% (2.02%) for MTB. Statistically significant differences were also observed for MPI and GBI at Week 2, and for all metrics at Week 6. Philips Sonicare FlexCare Platinum with Premium plaque control brush head statistically significantly reduces gingival inflammation, gingival bleeding, and plaque following two and six weeks of home use, compared to manual tooth brushing alone.
Development of HIV-1 Rectal-Specific Microbicides and Colonic Tissue Evaluation
Dezzutti, Charlene S.; Russo, Julie; Wang, Lin; Abebe, Kaleab Z.; Li, Jie; Friend, David R.; McGowan, Ian M.; Rohan, Lisa C.
2014-01-01
The gastrointestinal tract is structurally and functionally different from the vagina. Thus, the paradigm of topical microbicide development and evaluation has evolved to include rectal microbicides (RMs). Our interest was to create unique RM formulations to safely and effectively deliver antiretroviral drugs to mucosal tissue. RMs were designed to include those that spread and coat all surfaces of the rectum and distal colon rapidly (liquid) and those that create a deformable, erodible barrier and remain localized at the administration site (gel). Tenofovir (TFV) (1%) was formulated as an aqueous thermoreversible fluid and a carbopol-based aqueous hydrogel. Lipid-based liquid and gel formulations were prepared for UC781 (0.1%) using isopropyl myristate and GTCC (Caprylic/Capric Triglycerides), respectively. Formulations were characterized for pH, viscosity, osmolality, and drug content. Pre-clinical testing incorporated ex vivo colonic tissue obtained through surgical resections and flexible sigmoidoscopy (flex sig). As this was the first time using tissue from both sources side-by-side, the ability to replicate HIV-1 was compared. Efficacy of the RM formulations was tested by applying the products with HIV-1 directly to polarized colonic tissue and following viral replication. Safety of the formulations was determined by MTT assay and histology. All products had a neutral pH and were isoosmolar. While HIV-1BaL and HIV-1JR-CSF alone and in the presence of semen had similar replication trends between surgically resected and flex sig tissues, the magnitude of viral replication was significantly better in flex sig tissues. Both TFV and UC781 formulations protected the colonic tissue, regardless of tissue source, from HIV-1 and retained tissue viability and architecture. Our in vitro and ex vivo results show successful formulation of unique RMs. Moreover, the results of flex sig and surgically resected tissues were comparable suggesting the incorporation of both in pre-clinical testing algorithms. PMID:25025306
Armstrong, Sarah; Fernando, Roshan; Columb, Malachy; Jones, Tanya
2011-08-01
Aortocaval compression may affect maternal hemodynamic indices and fetal well-being in various maternal positions. There has been much debate regarding the optimal position for performing neuraxial blockade for labor analgesia and cesarean delivery. We hypothesized that in pregnant women at term, cardiac index (CI) may be improved in the lateral positions as compared with the flexed sitting position. Our primary outcome was to measure CI as assessed by suprasternal Doppler. A prospective, observational, crossover study was conducted in 25 ASA physical status I/II women with uncomplicated pregnancies presenting for elective cesarean delivery at term. Hemodynamic indices were measured in 4 positions in random order: supine with a 15-degree left tilt, sitting with neck and hips flexed, and flexed left lateral and flexed right lateral positions. Maternal CIs were measured using a noninvasive suprasternal Doppler device and upper arm noninvasive arterial blood pressure. Umbilical Dopplers were performed simultaneously to measure the fetal heart rate and umbilical artery pulsatility and resistivity indices. CI differed by position (P = 0.01); it was higher in the right lateral position compared with the sitting and supine positions (by 8.8% and 8.1%, respectively) and in the left lateral compared with sitting position (by 7.8%) (P < 0.05). Maternal stroke volume index, heart rate, and systolic blood pressure were higher in the lateral positions compared with the sitting and supine-tilt positions. We found no significant differences in fetal heart rate, pulsatility index, or resistivity index among positions. Positioning for neuraxial anesthesia may influence maternal hemodynamic variables. We found no difference in healthy fetal blood flow indices among positions, suggesting that these changes are not clinically significant. This study provides new physiological information on the changes that occur in a group in whom it has not been practical to study previously. Further study is necessary to determine whether these changes are significant in the presence of neuraxial anesthesia or in the high-risk parturient.
NASA Astrophysics Data System (ADS)
Suarez-Bertoa, R.; Zardini, A. A.; Platt, S. M.; Hellebust, S.; Pieber, S. M.; El Haddad, I.; Temime-Roussel, B.; Baltensperger, U.; Marchand, N.; Prévôt, A. S. H.; Astorga, C.
2015-09-01
Incentives to use biofuels may result in increasing vehicular emissions of compounds detrimental to air quality. Therefore, regulated and unregulated emissions from a Euro 5a flex-fuel vehicle, tested using E85 and E75 blends (gasoline containing 85% and 75% of ethanol (vol/vol), respectively), were investigated at 22 and -7 °C over the New European Driving Cycle, at the Vehicle Emission Laboratory at the European Commission Joint Research Centre Ispra, Italy. Vehicle exhaust was comprehensively analyzed at the tailpipe and in a dilution tunnel. A fraction of the exhaust was injected into a mobile smog chamber to study the photochemical aging of the mixture. We found that emissions from a flex-fuel vehicle, fueled by E85 and E75, led to secondary organic aerosol (SOA) formation, despite the low aromatic content of these fuel blends. Emissions of regulated and unregulated compounds, as well as emissions of black carbon (BC) and primary organic aerosol (POA) and SOA formation were higher at -7 °C. The flex-fuel unregulated emissions, mainly composed of ethanol and acetaldehyde, resulted in very high ozone formation potential and SOA, especially at low temperature (860 mg O3 km-1 and up to 38 mg C kg-1). After an OH exposure of 10 × 106 cm-3 h, SOA mass was, on average, 3 times larger than total primary particle mass emissions (BC + POA) with a high O:C ratio (up to 0.7 and 0.5 at 22 and -7 °C, respectively) typical of highly oxidized mixtures. Furthermore, high resolution organic mass spectra showed high 44/43 ratios (ratio of the ions m/z 44 and m/z 43) characteristic of low-volatility oxygenated organic aerosol. We also hypothesize that SOA formation from vehicular emissions could be due to oxidation products of ethanol and acetaldehyde, both short-chain oxygenated VOCs, e.g. methylglyoxal and acetic acid, and not only from aromatic compounds.
Insertion depth impacts speech perception and hearing preservation for lateral wall electrodes.
O'Connell, Brendan P; Hunter, Jacob B; Haynes, David S; Holder, Jourdan T; Dedmon, Matt M; Noble, Jack H; Dawant, Benoit M; Wanna, George B
2017-10-01
1) Examine angular insertion depths (AID) and scalar location of Med-El (GmbH Innsbruck, Austria) electrodes; and 2) determine the relationship between AID and audiologic outcomes controlling for scalar position. Retrospective review. Postlingually deafened adults undergoing cochlear implantation with Flex 24, Flex 28, and Standard electrode arrays (Med-El) were identified. Patients with preoperative and postoperative computed tomography scans were included so that electrode location and AID could be determined. Outcome measures were 1) speech perception in the cochlear implant (CI)-only condition, and 2) short-term hearing preservation. Forty-eight implants were included; all electrodes (48 of 48) were positioned entirely within the scala tympani. The median AID was 408° (interquartile [IQ] range 373°-449°) for Flex 24, 575° (IQ range 465°-584°) for Flex 28, and 584° (IQ range 368°-643°) for Standard electrodes (Med-El). The mean postoperative CNC score was 43.7% ± 21.9. A positive correlation was observed between greater AID and better CNC performance (r = 0.48, P < 0.001). Excluding patients with postoperative residual hearing, a strong correlation between AID and CNC persisted (r = 0.57, P < 0.001). In patients with preoperative residual hearing, mean low-frequency pure-tone average (PTA) shift was 27 dB ± 14. A correlation between AID and low-frequency PTA shift at activation was noted (r = 0.41, P = 0.04). Favorable rates of scala tympani insertion (100%) were observed. In the CI-only condition, a direct correlation between greater AID and CNC score was noted regardless of postoperative hearing status. Deeper insertions were, however, associated with worse short-term hearing preservation. When patients without postoperative residual hearing were analyzed independently, the relationship between greater insertion depth and better performance was strengthened. 4. Laryngoscope, 127:2352-2357, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.
Masuda, S; Furumatsu, T; Okazaki, Y; Kodama, Y; Hino, T; Kamatsuki, Y; Miyazawa, S; Ozaki, T
2018-04-10
A medial meniscus posterior root tear (MMPRT) is defined as an injury to the posterior meniscal insertion on the tibia. In MMPRT, the medial meniscus (MM) hoop function is damaged, and the MM undergoes a medial extrusion into the interior from the superior articular surface of the tibia. However, the details of MM position and movement during knee joint movement are unclear in MMPRT cases. The present study aims to evaluate MM position and movement via magnetic resonance imaging (MRI) examination of the MM posterior extrusion (MMPE) at knee flexion angles of 10° and 90°. We hypothesized that, during knee flexion, the MM will shift to the posterior and the posterior extrusion will increase compared to that when the knee is extended. Twenty-four patients were diagnosed with symptomatic MMPRT on open MRI examination. Preoperative MMPE, anteroposterior interval (API) of the MM, and MM medial extrusion (MMME) at knee flexion angles of 10° and 90° were measured. For patients with MMPRT, the MMPE increased from -4.77±1.43mm to 3.79±1.17mm (p<0.001) when the knee flexion angle increased from 10° to 90°. Further, flexing the knee from 10° to 90° decreased the API of the MM from 20.19±4.22mm to 16.41±5.14mm (p<0.001). MMME showed no significant change between knee flexion angles of 10° and 90°. This study demonstrated that, in cases of MMPRT, the MMPE clearly increases when the knee is flexed to 90°, while MMME does not change. Our results suggest that open MRI examination can be used to evaluate the dynamic position of the posterior MM by scanning the knee as it flexes to 90°. IV: retrospective cohort study. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
Development of HIV-1 rectal-specific microbicides and colonic tissue evaluation.
Dezzutti, Charlene S; Russo, Julie; Wang, Lin; Abebe, Kaleab Z; Li, Jie; Friend, David R; McGowan, Ian M; Rohan, Lisa C
2014-01-01
The gastrointestinal tract is structurally and functionally different from the vagina. Thus, the paradigm of topical microbicide development and evaluation has evolved to include rectal microbicides (RMs). Our interest was to create unique RM formulations to safely and effectively deliver antiretroviral drugs to mucosal tissue. RMs were designed to include those that spread and coat all surfaces of the rectum and distal colon rapidly (liquid) and those that create a deformable, erodible barrier and remain localized at the administration site (gel). Tenofovir (TFV) (1%) was formulated as an aqueous thermoreversible fluid and a carbopol-based aqueous hydrogel. Lipid-based liquid and gel formulations were prepared for UC781 (0.1%) using isopropyl myristate and GTCC (Caprylic/Capric Triglycerides), respectively. Formulations were characterized for pH, viscosity, osmolality, and drug content. Pre-clinical testing incorporated ex vivo colonic tissue obtained through surgical resections and flexible sigmoidoscopy (flex sig). As this was the first time using tissue from both sources side-by-side, the ability to replicate HIV-1 was compared. Efficacy of the RM formulations was tested by applying the products with HIV-1 directly to polarized colonic tissue and following viral replication. Safety of the formulations was determined by MTT assay and histology. All products had a neutral pH and were isoosmolar. While HIV-1BaL and HIV-1JR-CSF alone and in the presence of semen had similar replication trends between surgically resected and flex sig tissues, the magnitude of viral replication was significantly better in flex sig tissues. Both TFV and UC781 formulations protected the colonic tissue, regardless of tissue source, from HIV-1 and retained tissue viability and architecture. Our in vitro and ex vivo results show successful formulation of unique RMs. Moreover, the results of flex sig and surgically resected tissues were comparable suggesting the incorporation of both in pre-clinical testing algorithms.
Simos, Nikolaos
2017-12-22
Nikolaos Simos of Brookhavenâs Energy Sciences and Technology Department and the National Synchrotron Light Source II Project presents, âExtreme Environments of Next-Generation Energy Systems and Materials: Can They Peacefully Co-Exist?â
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 28 2011-07-01 2011-07-01 false Do I have to aggregate extremely hazardous substances to determine the total quantity present? 355.14 Section 355.14 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SUPERFUND, EMERGENCY PLANNING, AND COMMUNITY RIGHT-TO...
A walk on the tundra: Host-parasite interactions in an extreme environment
USDA-ARS?s Scientific Manuscript database
The Arctic is a vast, sparsely populated region that has captured the imagination and interest of explorers and scientists for generations. It is an environment of extremes and has been considered by many an inhospitable landscape and the last frontier to be explored. Despite the ‘hardships’ impos...
Xu, Kui; Ma, Chao; Lian, Jijian; Bin, Lingling
2014-01-01
Catastrophic flooding resulting from extreme meteorological events has occurred more frequently and drawn great attention in recent years in China. In coastal areas, extreme precipitation and storm tide are both inducing factors of flooding and therefore their joint probability would be critical to determine the flooding risk. The impact of storm tide or changing environment on flooding is ignored or underestimated in the design of drainage systems of today in coastal areas in China. This paper investigates the joint probability of extreme precipitation and storm tide and its change using copula-based models in Fuzhou City. The change point at the year of 1984 detected by Mann-Kendall and Pettitt’s tests divides the extreme precipitation series into two subsequences. For each subsequence the probability of the joint behavior of extreme precipitation and storm tide is estimated by the optimal copula. Results show that the joint probability has increased by more than 300% on average after 1984 (α = 0.05). The design joint return period (RP) of extreme precipitation and storm tide is estimated to propose a design standard for future flooding preparedness. For a combination of extreme precipitation and storm tide, the design joint RP has become smaller than before. It implies that flooding would happen more often after 1984, which corresponds with the observation. The study would facilitate understanding the change of flood risk and proposing the adaption measures for coastal areas under a changing environment. PMID:25310006
Xu, Kui; Ma, Chao; Lian, Jijian; Bin, Lingling
2014-01-01
Catastrophic flooding resulting from extreme meteorological events has occurred more frequently and drawn great attention in recent years in China. In coastal areas, extreme precipitation and storm tide are both inducing factors of flooding and therefore their joint probability would be critical to determine the flooding risk. The impact of storm tide or changing environment on flooding is ignored or underestimated in the design of drainage systems of today in coastal areas in China. This paper investigates the joint probability of extreme precipitation and storm tide and its change using copula-based models in Fuzhou City. The change point at the year of 1984 detected by Mann-Kendall and Pettitt's tests divides the extreme precipitation series into two subsequences. For each subsequence the probability of the joint behavior of extreme precipitation and storm tide is estimated by the optimal copula. Results show that the joint probability has increased by more than 300% on average after 1984 (α = 0.05). The design joint return period (RP) of extreme precipitation and storm tide is estimated to propose a design standard for future flooding preparedness. For a combination of extreme precipitation and storm tide, the design joint RP has become smaller than before. It implies that flooding would happen more often after 1984, which corresponds with the observation. The study would facilitate understanding the change of flood risk and proposing the adaption measures for coastal areas under a changing environment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bernhardt, A. F.; Smith, P. M.
This project was a collaborative effort between the University of California, Lawrence Livermore National Laboratory (LLNL) and FlexICs, Inc. to develop thin film transistor (TFT) electronics for active matrix displays.
Semi-flexible gas-insulated transmission line using electric field stress shields
Cookson, A.H.; Dale, S.J.; Bolin, P.C.
1982-12-28
A gas-insulated transmission line includes an outer sheath, an inner conductor, an insulating gas electrically insulating the inner conductor from the outer sheath, and insulating supports insulatably supporting the inner conductor within the outer sheath. The inner conductor is provided with flexibility by use of main conductor sections which are joined together through a conductor hub section and flexible flexing elements. Stress shields are provided to control the electric field at the locations of the conductor hub sections where the insulating supports are contacting the inner conductor. The flexing elements and the stress shields may also be utilized in connection with a plug and socket arrangement for providing electrical connection between main conductor sections. 10 figs.
Fabrication of Flex Joint Utilizing Additively Manufactured Parts
NASA Technical Reports Server (NTRS)
Eddleman, David; Richard, Jim
2015-01-01
The Selective Laser Melting (SLM) manufacturing technique has been utilized in the manufacture of a flex joint typical of those found in rocket engine and main propulsion system ducting. The SLM process allowed for the combination of parts that are typically machined separately and welded together. This resulted in roughly a 65% reduction of the total number of parts, roughly 70% reduction in the total number of welds, and an estimated 60% reduction in the number of machining operations. The majority of the new design was in three SLM pieces. These pieces, as well as a few traditionally fabricated parts, were assembled into a complete unit, which has been pressure tested. The design and planned cryogenic testing of the unit will be presented.
Mucci, Viviana
2018-01-01
Chest ultrasonography (CU) is a noninvasive imaging technique able to provide an immediate diagnosis of the underlying aetiology of acute respiratory failure and traumatic chest injuries. Given the great technologies, it is now possible to perform accurate CU in remote and adverse environments including the combat field, extreme sport settings, and environmental disasters, as well as during space missions. Today, the usage of CU in the extreme emergency setting is more likely to occur, as this technique proved to be a fast diagnostic tool to assist resuscitation manoeuvres and interventional procedures in many cases. A scientific literature review is presented here. This was based on a systematic search of published literature, on the following online databases: PubMed and Scopus. The following words were used: “chest sonography,” “ thoracic ultrasound,” and “lung sonography,” in different combinations with “extreme sport,” “extreme environment,” “wilderness,” “catastrophe,” and “extreme conditions.” This manuscript reports the most relevant usages of CU in the extreme setting as well as technological improvements and current limitations. CU application in the extreme setting is further encouraged here. PMID:29736195
Genomics and Metagenomics of Extreme Acidophiles in Biomining Environments
NASA Astrophysics Data System (ADS)
Holmes, D. S.
2015-12-01
Over 160 draft or complete genomes of extreme acidophiles (pH < 3) have been published, many of which are from bioleaching and other biomining environments, or are closely related to such microorganisms. In addition, there are over 20 metagenomic studies of such environments. This provides a rich source of latent data that can be exploited for understanding the biology of biomining environments and for advancing biotechnological applications. Genomic and metagenomic data are already yielding valuable insights into cellular processes, including carbon and nitrogen management, heavy metal and acid resistance, iron and sulfur oxido-reduction, linking biogeochemical processes to organismal physiology. The data also allow the construction of useful models of the ecophysiology of biomining environments and provide insight into the gene and genome evolution of extreme acidophiles. Additionally, since most of these acidophiles are also chemoautolithotrophs that use minerals as energy sources or electron sinks, their genomes can be plundered for clues about the evolution of cellular metabolism and bioenergetic pathways during the Archaean abiotic/biotic transition on early Earth. Acknowledgements: Fondecyt 1130683.
Robust, Thin Optical Films for Extreme Environments
NASA Technical Reports Server (NTRS)
2006-01-01
The environment of space presents scientists and engineers with the challenges of a harsh, unforgiving laboratory in which to conduct their scientific research. Solar astronomy and X-ray astronomy are two of the more challenging areas into which NASA scientists delve, as the optics for this high-tech work must be extremely sensitive and accurate, yet also be able to withstand the battering dished out by radiation, extreme temperature swings, and flying debris. Recent NASA work on this rugged equipment has led to the development of a strong, thin film for both space and laboratory use.
Toward Reliable and Energy Efficient Wireless Sensing for Space and Extreme Environments
NASA Technical Reports Server (NTRS)
Choi, Baek-Young; Boyd, Darren; Wilkerson, DeLisa
2017-01-01
Reliability is the critical challenge of wireless sensing in space systems operating in extreme environments. Energy efficiency is another concern for battery powered wireless sensors. Considering the physics of wireless communications, we propose an approach called Software-Defined Wireless Communications (SDC) that dynamically decide a reliable channel(s) avoiding unnecessary redundancy of channels, out of multiple distinct electromagnetic frequency bands such as radio and infrared frequencies.We validate the concept with Android and Raspberry Pi sensors and pseudo extreme experiments. SDC can be utilized in many areas beyond space applications.
USDA-ARS?s Scientific Manuscript database
Understanding naturally evolved adaptation to arid climates may be a key factor in developing crops that can thrive during extreme climate fluctuations. Malus sieversii (Ledeb.) M. Roem. is a wild apple species that has adapted to harsh environments in Kazakhstan, including extreme cold and dry reg...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 28 2011-07-01 2011-07-01 false How do I calculate the quantity of an extremely hazardous substance present in mixtures? 355.13 Section 355.13 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SUPERFUND, EMERGENCY PLANNING, AND COMMUNITY RIGHT-TO-KNOW PROGRAMS...
Flexible Electronics-Based Transformers for Extreme Environments
NASA Technical Reports Server (NTRS)
Quadrelli, Marco B.; Stoica, Adrian; Ingham, Michel; Thakur, Anubhav
2015-01-01
This paper provides a survey of the use of modular multifunctional systems, called Flexible Transformers, to facilitate the exploration of extreme and previously inaccessible environments. A novel dynamics and control model of a modular algorithm for assembly, folding, and unfolding of these innovative structural systems is also described, together with the control model and the simulation results.
Heat Shield for Extreme Entry Environment Technology (HEEET)
NASA Technical Reports Server (NTRS)
Venkatapathy, Ethiraj
2017-01-01
The Heat Shield for Extreme Entry Environment Technology (HEEET) project seeks to mature a game changing Woven Thermal Protection System (TPS) technology to enable in situ robotic science missions recommended by the NASA Research Council Planetary Science Decadal Survey committee. Recommended science missions include Venus probes and landers; Saturn and Uranus probes; and high-speed sample return missions.
Brine organisms and the question of habitat-specific adaptation
NASA Technical Reports Server (NTRS)
Siegel, B. Z.; Siegel, S. M.; Speitel, T.; Waber, J.; Stoecker, R.
1984-01-01
The question of adaptivity to extremely saline water environments is discussed, with attention given to the evolutionary performance of four common organisms including Cladonia skottsbergii, Penicillium notatum, Nostoc, and Dunaliella salina. Samples of each organism were collected and subjected to experimental conditions similar to extreme marine and limnetic environments in the Dead Sea and Don Juan Pond in the upper Wright valley of Antarctica. Measurements were made of isotope uptake and carbon dioxide production, and photoautotrophs were taken. It is found that all of the organisms responded quickly to the need to adapt to the extreme environments. It is concluded that a degree of uncertainty exists in the perception that the abundance of bulk water on the earth is in itself essential for life.
NASA Technical Reports Server (NTRS)
Carr, Gregory A.; Iannello, Christopher J.; Chen, Yuan; Hunter, Don J.; DelCastillo, Linda; Bradley, Arthur T.; Stell, Christopher; Mojarradi, Mohammad M.
2013-01-01
This paper is to present a concept of a modular and scalable High Temperature Boost (HTB) Power Processing Unit (PPU) capable of operating at temperatures beyond the standard military temperature range. The various extreme environments technologies are also described as the fundamental technology path to this concept. The proposed HTB PPU is intended for power processing in the area of space solar electric propulsion, where reduction of in-space mass and volume are desired, and sometimes even critical, to achieve the goals of future space flight missions. The concept of the HTB PPU can also be applied to other extreme environment applications, such as geothermal and petroleum deep-well drilling, where higher temperature operation is required.
NASA Technical Reports Server (NTRS)
Carr, Gregory A.; Iannello, Christopher J.; Chen, Yuan; Hunter, Don J.; Del Castillo, Linda; Bradley, Arthur T.; Stell, Christopher; Mojarradi, Mohammad M.
2013-01-01
This paper is to present a concept of a modular and scalable High Temperature Boost (HTB) Power Processing Unit (PPU) capable of operating at temperatures beyond the standard military temperature range. The various extreme environments technologies are also described as the fundamental technology path to this concept. The proposed HTB PPU is intended for power processing in the area of space solar electric propulsion, where the reduction of in-space mass and volume are desired, and sometimes even critical, to achieve the goals of future space flight missions. The concept of the HTB PPU can also be applied to other extreme environment applications, such as geothermal and petroleum deep-well drilling, where higher temperature operation is required.
Development and Testing of Mechanism Technology for Space Exploration in Extreme Environments
NASA Technical Reports Server (NTRS)
Tyler, Tony R.; Levanas, Greg; Mojarradi, Mohammad M.; Abel, Phillip B.
2011-01-01
The NASA Jet Propulsion Lab (JPL), Glenn Research Center (GRC), Langley Research Center (LaRC), and Aeroflex, Inc. have partnered to develop and test actuator hardware that will survive the stringent environment of the moon, and which can also be leveraged for other challenging space exploration missions. Prototype actuators have been built and tested in a unique low temperature test bed with motor interface temperatures as low as 14 degrees Kelvin. Several years of work have resulted in specialized electro-mechanical hardware to survive extreme space exploration environments, a test program that verifies and finds limitations of the designs at extreme temperatures, and a growing knowledge base that can be leveraged by future space exploration missions.
NASA Technical Reports Server (NTRS)
Kaufman, J. W. (Editor)
1977-01-01
Guidelines are provided on terrestrial environment data specifically applicable for NASA aerospace vehicles and associated equipment development. Information is included on the general distribution of natural environment extremes in the conterminous United States that may be needed to specify design criteria in the transportation of space vehicle subsystems and components. Atmospheric attenuation was investigated since certain earth orbital experiment missions are influenced by the earth's atmosphere. A summary of climatic extremes for worldwide operational needs is also included. The latest available information on probable climatic extremes is presented with information on atmospheric chemistry, seismic criteria, and on a mathematical model to predict atmospheric dispersion of aerospace engine exhaust cloud rise and growth. Cloud phenomena are also considered.
Phosphatase activity in Antarctica soil samples as a biosignature of extant life
NASA Astrophysics Data System (ADS)
Sato, Shuji; Itoh, Yuki; Takano, Yoshinori; Fukui, Manabu; Kaneko, Takeo; Kobayashi, Kensei
Microbial activities have been detected in such extreme terrestrial environments as deep lithosphere, a submarine hydrothermal systems, stratosphere, and Antarctica. Microorganisms have adapted to such harsh environments by evolving their biomolecules. Some of these biomolecules such as enzymes might have different characteristics from those of organisms in ordinary environments. Many biosignatures (or biomarkers) have been proposed to detect microbial activities in such extreme environments. A number of techniques are proposed to evaluate biological activities in extreme environments including cultivation methods, assay of metabolism, and analysis of bioorganic compounds like amino acids and DNA. Enzyme activities are useful signature of extant life in extreme environments. Among many enzymes, phosphatase could be a good indicator of biological activities, since phosphate esters are essential for all the living terrestrial organisms. In addition, alkaline phosphatase is known as a typical zinc-containing metalloenzyme and quite stable in environments. We analyzed phosphatase activities in Antarctica soil samples to see whether they can be used as biosignatures for extant life. In addition, we characterized phosphatases extracted from the Antarctica soil samples, and compared with those obtained from other types of environments. Antarctica surface environments are quite severe environments for life since it is extremely cold and dry and exposed to strong UV and cosmic rays. We tried to evaluate biological activities in Antarctica by measuring phosphatase activities. Surface soil samples are obtained at the Sites 1-8 near Showa Base in Antarctica during the 47th Japan Antarctic exploration mission in 2005-6. Activities of acid phosphatase (ACP) and alkaline phosphatase (ALP) are measured spectrophotometrically after mixing the powdered sample and p-nitrophenyl phosphate solution (pH 6.5 for ACP, pH 8.0 for ALP). ALP was characterized after extraction from soils with Tris-HCl buffer (pH 9.0), where the activity was measured fluorometrically with 4-methylumbelliferyl phosphate (pH 8.0) as a substance. The soil of Site 8 (near a penguin rookery) showed almost the same level of ACP and ALP activities as usual surface soil sampled in YNU campus, while the soil of Sites 1-7 showed much less activities. ALP in the extract from the soil of Site 8 was characterized. It showed the maximal at 338 K, while ALP from the campus soil showed the maximal at 358 K. Gel filtration chromatography showed that the ALP activity was found only in the fraction whose molecular weights were over 60000. The ALP activity was diminished with EDTA and was recovered with addition of zinc ion. The present results showed that zinc-containing metalloenzymes, which had lower optimum temperature than those in usual environments, are present in Antarctica soil. It was suggested that phosphatases are good bio-signatures for extant life in extreme environments.
Xu, Jian; Li, Jiong-Tang; Jiang, Yanliang; Peng, Wenzhu; Yao, Zongli; Chen, Baohua; Jiang, Likun; Feng, Jingyan; Ji, Peifeng; Liu, Guiming; Liu, Zhanjiang; Tai, Ruyu; Dong, Chuanju; Sun, Xiaoqing; Zhao, Zi-Xia; Zhang, Yan; Wang, Jian; Li, Shangqi; Zhao, Yunfeng; Yang, Jiuhui; Sun, Xiaowen; Xu, Peng
2017-01-01
The Amur ide (Leuciscus waleckii) is a cyprinid fish that is widely distributed in Northeast Asia. The Lake Dali Nur population inhabits one of the most extreme aquatic environments on Earth, with an alkalinity up to 50 mmol/L (pH 9.6), thus providing an exceptional model with which to characterize the mechanisms of genomic evolution underlying adaptation to extreme environments. Here, we developed the reference genome assembly for L. waleckii from Lake Dali Nur. Intriguingly, we identified unusual expanded long terminal repeats (LTRs) with higher nucleotide substitution rates than in many other teleosts, suggesting their more recent insertion into the L. waleckii genome. We also identified expansions in genes encoding egg coat proteins and natriuretic peptide receptors, possibly underlying the adaptation to extreme environmental stress. We further sequenced the genomes of 10 additional individuals from freshwater and 18 from Lake Dali Nur populations, and we detected a total of 7.6 million SNPs from both populations. In a genome scan and comparison of these two populations, we identified a set of genomic regions under selective sweeps that harbor genes involved in ion homoeostasis, acid-base regulation, unfolded protein response, reactive oxygen species elimination, and urea excretion. Our findings provide comprehensive insight into the genomic mechanisms of teleost fish that underlie their adaptation to extreme alkaline environments. PMID:28007977
NASA Astrophysics Data System (ADS)
Giesige, C.; Nava, E.
2016-12-01
In the midst of a changing climate we have seen extremes in weather events: lightning, wildfires, hurricanes, tornadoes, and earthquakes. All of these ride on an imbalance of magnetic and electrical distribution about the earth including what goes on from the atmospheric and geophysic levels. There is relevance to the important role the sun plays in developing and feeding of the extreme weather events along with the sun's role helping to create a separation of charges on earth furthering climactic extremes. Focusing attention in North America and on how the sun, atmospheric and geophysic winds come together producing lightning events, there are connections between energy distribution in the environment, lightning caused wildfires, and extreme wildfire behavior. Lightning caused wildfires and extreme fire behavior have become enhanced with the changing climate conditions. Even with strong developments in wildfire science, there remains a lack in full understanding of connections that create a lightning caused wildfire event and lack of monitoring advancements in predicting extreme fire behavior. Several connections have been made in our research allowing us to connect multiple facets of the environment in regards to electric and magnetic influences on wildfires. Among them include: irradiance, winds, pressure systems, humidity, and topology. The connections can be made to develop better detection systems of wildfires, establish with more accuracy areas of highest risk for wildfire and extreme wildfire behavior, and prediction of wildfire behavior. A platform found within the environment can also lead to further understanding and monitoring of other extreme weather events in the future.
Fabrication of diamond based sensors for use in extreme environments
Samudrala, Gopi K.; Moore, Samuel L.; Vohra, Yogesh K.
2015-04-23
Electrical and magnetic sensors can be lithographically fabricated on top of diamond substrates and encapsulated in a protective layer of chemical vapor deposited single crystalline diamond. This process when carried out on single crystal diamond anvils employed in high pressure research is termed as designer diamond anvil fabrication. These designer diamond anvils allow researchers to study electrical and magnetic properties of materials under extreme conditions without any possibility of damaging the sensing elements. We describe a novel method for the fabrication of designer diamond anvils with the use of maskless lithography and chemical vapor deposition in this paper. This methodmore » can be utilized to produce diamond based sensors which can function in extreme environments of high pressures, high and low temperatures, corrosive and high radiation conditions. Here, we demonstrate applicability of these diamonds under extreme environments by performing electrical resistance measurements during superconducting transition in rare earth doped iron-based compounds under high pressures to 12 GPa and low temperatures to 10 K.« less
Fabrication of diamond based sensors for use in extreme environments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Samudrala, Gopi K.; Moore, Samuel L.; Vohra, Yogesh K.
Electrical and magnetic sensors can be lithographically fabricated on top of diamond substrates and encapsulated in a protective layer of chemical vapor deposited single crystalline diamond. This process when carried out on single crystal diamond anvils employed in high pressure research is termed as designer diamond anvil fabrication. These designer diamond anvils allow researchers to study electrical and magnetic properties of materials under extreme conditions without any possibility of damaging the sensing elements. We describe a novel method for the fabrication of designer diamond anvils with the use of maskless lithography and chemical vapor deposition in this paper. This methodmore » can be utilized to produce diamond based sensors which can function in extreme environments of high pressures, high and low temperatures, corrosive and high radiation conditions. Here, we demonstrate applicability of these diamonds under extreme environments by performing electrical resistance measurements during superconducting transition in rare earth doped iron-based compounds under high pressures to 12 GPa and low temperatures to 10 K.« less
[Range of Hip Joint Motion and Weight of Lower Limb Function under 3D Dynamic Marker].
Xia, Q; Zhang, M; Gao, D; Xia, W T
2017-12-01
To explore the range of reasonable weight coefficient of hip joint in lower limb function. When the hip joints of healthy volunteers under normal conditions or fixed at three different positions including functional, flexed and extension positions, the movements of lower limbs were recorded by LUKOtronic motion capture and analysis system. The degree of lower limb function loss was calculated using Fugl-Meyer lower limb function assessment form when the hip joints were fixed at the aforementioned positions. One-way analysis of variance and Tamhane's T2 method were used to proceed statistics analysis and calculate the range of reasonable weight coefficient of hip joint. There were significant differences between the degree of lower limb function loss when the hip joints fixed at flexed and extension positions and at functional position. While the differences between the degree of lower limb function loss when the hip joints fixed at flexed position and extension position had no statistical significance. In 95% confidence interval, the reasonable weight coefficient of hip joint in lower limb function was between 61.05% and 73.34%. Expect confirming the reasonable weight coefficient, the effects of functional and non-functional positions on the degree of lower limb function loss should also be considered for the assessment of hip joint function loss. Copyright© by the Editorial Department of Journal of Forensic Medicine
NASA Astrophysics Data System (ADS)
Sanz, D.; Ruiz, M.; Castro, R.; Vega, J.; Afif, M.; Monroe, M.; Simrock, S.; Debelle, T.; Marawar, R.; Glass, B.
2016-04-01
To aid in assessing the functional performance of ITER, Fission Chambers (FC) based on the neutron diagnostic use case deliver timestamped measurements of neutron source strength and fusion power. To demonstrate the Plant System Instrumentation & Control (I&C) required for such a system, ITER Organization (IO) has developed a neutron diagnostics use case that fully complies with guidelines presented in the Plant Control Design Handbook (PCDH). The implementation presented in this paper has been developed on the PXI Express (PXIe) platform using products from the ITER catalog of standard I&C hardware for fast controllers. Using FlexRIO technology, detector signals are acquired at 125 MS/s, while filtering, decimation, and three methods of neutron counting are performed in real-time via the onboard Field Programmable Gate Array (FPGA). Measurement results are reported every 1 ms through Experimental Physics and Industrial Control System (EPICS) Channel Access (CA), with real-time timestamps derived from the ITER Timing Communication Network (TCN) based on IEEE 1588-2008. Furthermore, in accordance with ITER specifications for CODAC Core System (CCS) application development, the software responsible for the management, configuration, and monitoring of system devices has been developed in compliance with a new EPICS module called Nominal Device Support (NDS) and RIO/FlexRIO design methodology.
Han, H S; Kang, S-B; Yoon, K S
2007-11-01
We have examined the results obtained with 72 NexGen legacy posterior stabilised-flex fixed total knee replacements in 47 patients implanted by a single surgeon between March 2003 and September 2004. Aseptic loosening of the femoral component was found in 27 (38%) of the replacements at a mean follow-up of 32 months (30 to 48) and 15 knees (21%) required revision at a mean of 23 months (11 to 45). We compared the radiologically-loose and revised knees with those which had remained well-fixed to identify the factors which had contributed to this high rate of aseptic loosening. Post-operatively, the mean maximum flexion was 136 degrees (110 degrees to 140 degrees) in the loosened group and 125 degrees (95 degrees to 140 degrees) in the well-fixed group (independent t-test, p = 0.022). Squatting, kneeling, or sitting cross-legged could be achieved by 23 (85%) of the loosened knees, but only 22 (49%) of the well-fixed knees (chi-squared test, p = 0.001). The loosened femoral components were found to migrate into a more flexed position, but no migration was detected in the well-fixed group. These implants allowed a high degree of flexion, but showed a marked rate of early loosening of the femoral component, which was associated with weight-bearing in maximum flexion.
Anatomy of the anterior cruciate ligament with regard to its two bundles.
Petersen, Wolf; Zantop, Thore
2007-01-01
The anterior cruciate ligament (ACL) consists of two major fiber bundles, namely the anteromedial and posterolateral bundle. When the knee is extended, the posterolateral bundle (PL) is tight and the anteromedial (AM) bundle is moderately lax. As the knee is flexed, the femoral attachment of the ACL becomes a more horizontal orientation; causing the AM bundle to tighten and the PL bundle to relax. There is some degree of variability for the femoral origin of the anterome-dial and posterolateral bundle. The anteromedial bundle is located proximal and anterior in the femoral ACL origin (high and deep in the notch when the knee is flexed at 90 degrees ); the posterolateral bundle starts in the distal and posterior aspect of the femoral ACL origin (shallow and low when the knee is flexed at 90 degrees ). In the frontal plane the anteromedial bundle origin is in the 10:30 clock position and the postero-lateral bundle origin in the 9:30 clock position. At the tibial insertion the ACL fans out to form the foot region. The anteromedial bundle insertion is in the anterior part of the tibial ACL footprint, the posterolateral bundle in the posterior part. While the anteromedial bundle is the primary restraint against anterior tibial translation, the posterolateral bundle tends to stabilize the knee near full extension, particularly against rotatory loads.
Reid, Duncan; McNair, Peter J; Johnson, Shelley; Potts, Geoff; Witvrouw, Erik; Mahieu, Nele
2012-08-01
To compare surface electromyographic (EMG) activity of the gastrocnemius and soleus muscles between persons with and without Achilles tendinopathy (AT) during an eccentric muscle exercise in different knee joint positions. Repeated measures design. Research laboratory. Participants (n = 18) diagnosed with AT and 18 control subjects were recruited. Gastrocnemius and soleus muscle activity was examined by surface (EMG) during extended and flexed knee joint conditions while performing the eccentric training technique. The EMG data were expressed as a percentage of a maximum voluntary contraction (MVC). EMG activity was notably higher (mean difference: 10%, effect size: 0.59) in those subjects with AT. Irrespective of the presence of AT, there was a significant interaction effect between muscle and joint position. The gastrocnemius muscle was significantly more active in the extended knee condition and soleus muscle activity was unchanged across joint positions. The results indicated that the presence of AT influenced calf muscle activity levels during performance of the eccentric exercise. There were differences in muscle activity during the extended and flexed knee conditions. This result does support performing Alfredson, Pietila, Jonsson, and Lorentzon (1998) eccentric exercise in an extended knee position but the specific effects of the knee flexed position on the Achilles tendon during eccentric exercise have yet to be determined, particularly in those with AT. Copyright © 2011 Elsevier Ltd. All rights reserved.
Assessing and enhancing the utility of low-cost activity and location sensors for exposure studies.
Asimina, Stamatelopoulou; Chapizanis, D; Karakitsios, S; Kontoroupis, P; Asimakopoulos, D N; Maggos, T; Sarigiannis, D
2018-02-20
Nowadays, the advancement of mobile technology in conjunction with the introduction of the concept of exposome has provided new dynamics to the exposure studies. Since the addressing of health outcomes related to environmental stressors is crucial, the improvement of exposure assessment methodology is of paramount importance. Towards this aim, a pilot study was carried out in the two major cities of Greece (Athens, Thessaloniki), investigating the applicability of commercially available fitness monitors and the Moves App for tracking people's location and activities, as well as for predicting the type of the encountered location, using advanced modeling techniques. Within the frame of the study, 21 individuals were using the Fitbit Flex activity tracker, a temperature logger, and the application Moves App on their smartphones. For the validation of the above equipment, participants were also carrying an Actigraph (activity sensor) and a GPS device. The data collected from Fitbit Flex, the temperature logger, and the GPS (speed) were used as input parameters in an Artificial Neural Network (ANN) model for predicting the type of location. Analysis of the data showed that the Moves App tends to underestimate the daily steps counts in comparison with Fitbit Flex and Actigraph, respectively, while Moves App predicted the movement trajectory of an individual with reasonable accuracy, compared to a dedicated GPS. Finally, the encountered location was successfully predicted by the ANN in most of the cases.
Intrinsic domain wall flexing from current-induced spin torque
NASA Astrophysics Data System (ADS)
Golovatski, Elizabeth; Flatté, Michael
2012-02-01
Spin torque generated by coherent carrier transport in domain walls [1] is a major component in the development of spintronic devices [2]. We model spin torque in N'eel walls [3] using a piecewise linear transfer-matrix method [4] to calculate spin torque on interior wall segments. For a π wall with a total positive torque (current left-to-right), we find the largest positive and negative spin torques left of the central region, 4-5 orders of magnitude larger than the center. The wall's rightward push comes from the back of the wall; all other significant regions pull to the left. Adding a second wall (both walls with positive total torque) changes the first wall little, but produces spin torques in the second wall with large canceling torques on the left, and the push rightward from a smaller torque on the right. The gradient of torque across the wall generates an intrinsic domain wall flexing (distinct from extrinsic wall flexing from pinning centers [5]). Work supported by an ARO MURI.[4pt] [1] M. Yamanouchi et al., Nature 428, 539 (2004).[0pt] [2] S. Parkin et al., Science 320, 190 (2008)[0pt] [3] G. Vignale and M. Flatt'e, Phys. Rev. Lett. 89, 098302 (2002)[0pt] [4] E. Golovatski and M. Flatt'e, Phys. Rev. B, 84, 115210 (2011)[0pt] [5] A. Balk et al., Phys. Rev. Lett. 107, 077205 (2011).
Aerodynamics of dynamic wing flexion in translating wings
NASA Astrophysics Data System (ADS)
Liu, Yun; Cheng, Bo; Sane, Sanjay P.; Deng, Xinyan
2015-06-01
We conducted a systematic experimental study to investigate the aerodynamic effects of active trailing-edge flexion on a high-aspect-ratio wing translating from rest at a high angle of attack. We varied the timing and speed of the trailing-edge flexion and measured the resulting aerodynamic effects using a combination of direct force measurements and two-dimensional PIV flow measurements. The results indicated that the force and flow characteristics depend strongly on the timing of flexion, but relatively weakly on its speed. This is because the force and vortical flow structure are more sensitive to the timing of flexion relative to the shedding of starting vortex and leading-edge vortex. When the trailing-edge flexion occurred slightly before the starting vortex was shed, the lift production was greatly improved with the instantaneous peak lift increased by 54 % and averaged lift increased by 21 % compared with the pre-flexed case where the trailing-edge flexed before wing translation. However, when the trailing-edge flexed during or slightly after the leading-edge vortex shedding, the lift was significantly reduced by the disturbed development of leading-edge vortex. The force measurement results also imply that the trailing-edge flexion prior to wing translation does not augment lift but increases drag, thus resulting in a lower lift-drag ratio as compared to the case of flat wing.
Elastic all-optical multi-hop interconnection in data centers with adaptive spectrum allocation
NASA Astrophysics Data System (ADS)
Hong, Yuanyuan; Hong, Xuezhi; Chen, Jiajia; He, Sailing
2017-01-01
In this paper, a novel flex-grid all-optical interconnect scheme that supports transparent multi-hop connections in data centers is proposed. An inter-rack all-optical multi-hop connection is realized with an optical loop employed at flex-grid wavelength selective switches (WSSs) in an intermediate rack rather than by relaying through optical-electric-optical (O-E-O) conversions. Compared with the conventional O-E-O based approach, the proposed all-optical scheme is able to off-load the traffic at intermediate racks, leading to a reduction of the power consumption and cost. The transmission performance of the proposed flex-grid multi-hop all-optical interconnect scheme with various modulation formats, including both coherently detected and directly detected approaches, are investigated by Monte-Carlo simulations. To enhance the spectrum efficiency (SE), number-of-hop adaptive bandwidth allocation is introduced. Numerical results show that the SE can be improved by up to 33.3% at 40 Gbps, and by up to 25% at 100 Gbps. The impact of parameters, such as targeted bit error rate (BER) level and insertion loss of components, on the transmission performance of the proposed approach are also explored. The results show that the maximum SE improvement of the adaptive approach over the non-adaptive one is enhanced with the decrease of the targeted BER levels and the component insertion loss.
Aerodynamic Drag Analysis of 3-DOF Flex-Gimbal GyroWheel System in the Sense of Ground Test
Huo, Xin; Feng, Sizhao; Liu, Kangzhi; Wang, Libin; Chen, Weishan
2016-01-01
GyroWheel is an innovative device that combines the actuating capabilities of a control moment gyro with the rate sensing capabilities of a tuned rotor gyro by using a spinning flex-gimbal system. However, in the process of the ground test, the existence of aerodynamic disturbance is inevitable, which hinders the improvement of the specification performance and control accuracy. A vacuum tank test is a possible candidate but is sometimes unrealistic due to the substantial increase in costs and complexity involved. In this paper, the aerodynamic drag problem with respect to the 3-DOF flex-gimbal GyroWheel system is investigated by simulation analysis and experimental verification. Concretely, the angular momentum envelope property of the spinning rotor system is studied and its integral dynamical model is deduced based on the physical configuration of the GyroWheel system with an appropriately defined coordinate system. In the sequel, the fluid numerical model is established and the model geometries are checked with FLUENT software. According to the diversity and time-varying properties of the rotor motions in three-dimensions, the airflow field around the GyroWheel rotor is analyzed by simulation with respect to its varying angular velocity and tilt angle. The IPC-based experimental platform is introduced, and the properties of aerodynamic drag in the ground test condition are obtained through comparing the simulation with experimental results. PMID:27941602
Research on Nitride Thin Films, Advanced Plasma Diagnostics, and Charged-Particle Processes
2006-07-01
Additionally, these components are being placed closer to the point of use--requiring that they operate in extreme temperature environments ...reasons for component failure. To operate in extreme temperature environments , electronic and electrical components must withstand higher ambient...hybrid and plug-in hybrid-powered automobiles, heart defibrillators , and industrial equipment will benefit from a new generation of capacitors. High
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 29 2012-07-01 2012-07-01 false The List of Extremely Hazardous Substances and Their Threshold Planning Quantities B Appendix B to Part 355 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SUPERFUND, EMERGENCY PLANNING, AND COMMUNITY RIGHT-TO-KNOW PROGRAMS EMERGENCY PLANNING AND NOTIFICATION Pt....
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 28 2014-07-01 2014-07-01 false The List of Extremely Hazardous Substances and Their Threshold Planning Quantities A Appendix A to Part 355 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SUPERFUND, EMERGENCY PLANNING, AND COMMUNITY RIGHT-TO-KNOW PROGRAMS EMERGENCY PLANNING AND NOTIFICATION Pt....
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 29 2012-07-01 2012-07-01 false The List of Extremely Hazardous Substances and Their Threshold Planning Quantities A Appendix A to Part 355 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SUPERFUND, EMERGENCY PLANNING, AND COMMUNITY RIGHT-TO-KNOW PROGRAMS EMERGENCY PLANNING AND NOTIFICATION Pt....
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 28 2014-07-01 2014-07-01 false The List of Extremely Hazardous Substances and Their Threshold Planning Quantities B Appendix B to Part 355 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SUPERFUND, EMERGENCY PLANNING, AND COMMUNITY RIGHT-TO-KNOW PROGRAMS EMERGENCY PLANNING AND NOTIFICATION Pt....
Passmore, Brandon; Cole, Zach; Whitaker, Bret; Barkley, Adam; McNutt, Ty; Lostetter, Alexander
2016-08-02
A multichip power module directly connecting the busboard to a printed-circuit board that is attached to the power substrate enabling extremely low loop inductance for extreme environments such as high temperature operation. Wire bond interconnections are taught from the power die directly to the busboard further enabling enable low parasitic interconnections. Integration of on-board high frequency bus capacitors provide extremely low loop inductance. An extreme environment gate driver board allows close physical proximity of gate driver and power stage to reduce overall volume and reduce impedance in the control circuit. Parallel spring-loaded pin gate driver PCB connections allows a reliable and reworkable power module to gate driver interconnections.
Kim, Aram; Kretch, Kari S; Zhou, Zixuan; Finley, James M
2018-05-09
Successful negotiation of obstacles during walking relies on the integration of visual information about the environment with ongoing locomotor commands. When information about the body and environment are removed through occlusion of the lower visual field, individuals increase downward head pitch angle, reduce foot placement precision, and increase safety margins during crossing. However, whether these effects are mediated by loss of visual information about the lower extremities, the obstacle, or both remains to be seen. Here, we used a fully immersive, virtual obstacle negotiation task to investigate how visual information about the lower extremities is integrated with information about the environment to facilitate skillful obstacle negotiation. Participants stepped over virtual obstacles while walking on a treadmill with one of three types of visual feedback about the lower extremities: no feedback, end-point feedback, or a link-segment model. We found that absence of visual information about the lower extremities led to an increase in the variability of leading foot placement after crossing. The presence of a visual representation of the lower extremities promoted greater downward head pitch angle during the approach to and subsequent crossing of an obstacle. In addition, having greater downward head pitch was associated with closer placement of the trailing foot to the obstacle, further placement of the leading foot after the obstacle, and higher trailing foot clearance. These results demonstrate that the fidelity of visual information about the lower extremities influences both feed-forward and feedback aspects of visuomotor coordination during obstacle negotiation.
Lightweight Modular Instrumentation for Planetary Applications
NASA Technical Reports Server (NTRS)
Joshi, P. B.
1993-01-01
An instrumentation, called Space Active Modular Materials ExperimentS (SAMMES), is developed for monitoring the spacecraft environment and for accurately measuring the degradation of space materials in low earth orbit (LEO). The SAMMES architecture concept can be extended to instrumentation for planetary exploration, both on spacecraft and in situ. The operating environment for planetary application will be substantially different, with temperature extremes and harsh solar wind and cosmic ray flux on lunar surfaces and temperature extremes and high winds on venusian and Martian surfaces. Moreover, instruments for surface deployment, which will be packaged in a small lander/rover (as in MESUR, for example), must be extremely compact with ultralow power and weight. With these requirements in mind, the SAMMES concept was extended to a sensor/instrumentation scheme for the lunar and Martian surface environment.
NASA Technical Reports Server (NTRS)
Okon, Avi B.
2010-01-01
The Drill for the Mars Science Laboratory mission is a rotary-percussive sample acquisition device with an emphasis on toughness and robustness to handle the harsh environment on Mars. The unique challenges associated with autonomous drilling from a mobile robot are addressed. A highly compressed development schedule dictated a modular design architecture that satisfies the functional and load requirements while allowing independent development and testing of the Drill subassemblies. The Drill consists of four actuated mechanisms: a spindle that rotates the bit, a chuck that releases and engages bits, a novel voice-coil-based percussion mechanism that hammers the bit, and a linear translation mechanism. The Drill has three passive mechanisms: a replaceable bit assembly that acquires and collects sample, a contact sensor / stabilizer mechanism, and, lastly a flex harness service loop. This paper describes the various mechanisms that makeup the Drill and discusses the solutions to their unique design and development challenges.
Dynamic analysis of rotor flex-structure based on nonlinear anisotropic shell models
NASA Astrophysics Data System (ADS)
Bauchau, Olivier A.; Chiang, Wuying
1991-05-01
In this paper an anisotropic shallow shell model is developed that accommodates transverse shearing deformations and arbitrarily large displacements and rotations, but strains are assumed to remain small. Two kinematic models are developed, the first using two DOF to locate the direction of the normal to the shell's midplane, the second using three. The latter model allows for an automatic compatibility of the shell model with beam models. The shell model is validated by comparing its predictions with several benchmark problems. In actual helicopter rotor blade problems, the shell model of the flex structure is shown to give very different results shown compared to beam models. The lead-lag and torsion modes in particular are strongly affected, whereas flapping modes seem to be less affected.
Begalle, Rebecca L; Walsh, Meghan C; McGrath, Melanie L; Boling, Michelle C; Blackburn, J Troy; Padua, Darin A
2015-08-01
The ankle, knee, and hip joints work together in the sagittal plane to absorb landing forces. Reduced sagittal plane motion at the ankle may alter landing strategies at the knee and hip, potentially increasing injury risk; however, no studies have examined the kinematic relationships between the joints during jump landings. Healthy adults (N = 30; 15 male, 15 female) performed jump landings onto a force plate while three-dimensional kinematic data were collected. Joint displacement values were calculated during the loading phase as the difference between peak and initial contact angles. No relationship existed between ankle dorsiflexion displacement during landing and three-dimensional knee and hip displacements. However, less ankle dorsiflexion displacement was associated with landing at initial ground contact with larger hip flexion, hip internal rotation, knee flexion, knee varus, and smaller plantar flexion angles. Findings of the current study suggest that restrictions in ankle motion during landing may contribute to contacting the ground in a more flexed position but continuing through little additional motion to absorb the landing. Transverse plane hip and frontal plane knee positioning may also occur, which are known to increase the risk of lower extremity injury.
High-performance wire-grid polarizers using jet and Flash™ imprint lithography
NASA Astrophysics Data System (ADS)
Ahn, Se Hyun; Yang, Shuqiang; Miller, Mike; Ganapathisubramanian, Maha; Menezes, Marlon; Choi, Jin; Xu, Frank; Resnick, Douglas J.; Sreenivasan, S. V.
2013-07-01
Extremely large-area roll-to-roll (R2R) manufacturing on flexible substrates is ubiquitous for applications such as paper and plastic processing. It combines the benefits of high speed and inexpensive substrates to deliver a commodity product at low cost. The challenge is to extend this approach to the realm of nanopatterning and realize similar benefits. In order to achieve low-cost nanopatterning, it is imperative to move toward high-speed imprinting, less complex tools, near zero waste of consumables, and low-cost substrates. We have developed a roll-based J-FIL process and applied it to a technology demonstrator tool, the LithoFlex 100, to fabricate large-area flexible bilayer wire-grid polarizers (WGPs) and high-performance WGPs on rigid glass substrates. Extinction ratios of better than 10,000 are obtained for the glass-based WGPs. Two simulation packages are also employed to understand the effects of pitch, aluminum thickness, and pattern defectivity on the optical performance of the WGP devices. It is determined that the WGPs can be influenced by both clear and opaque defects in the gratings; however, the defect densities are relaxed relative to the requirements of a high-density semiconductor device.
High volume nanoscale roll-based imprinting using jet and flash imprint lithography
NASA Astrophysics Data System (ADS)
Ahn, Se Hyun; Miller, Mike; Yang, Shuqiang; Ganapathisubramanian, Maha; Menezes, Marlon; Singh, Vik; Choi, Jin; Xu, Frank; LaBrake, Dwayne; Resnick, Douglas J.; Sreenivasan, S. V.
2013-09-01
Extremely large-area roll-to-roll (R2R) manufacturing on flexible substrates is ubiquitous for applications such as paper and plastic processing. It combines the benefits of high speed and inexpensive substrates to deliver a commodity product at low cost. The challenge is to extend this approach to the realm of nanopatterning and realize similar benefits. In order to achieve low-cost nanopatterning, it is imperative to move toward high-speed imprinting, less complex tools, near zero waste of consumables, and low-cost substrates. We have developed a roll-based J-FIL process and applied it to a technology demonstrator tool, the LithoFlex 100, to fabricate large-area flexible bilayer wire-grid polarizers (WGPs) and high-performance WGPs on rigid glass substrates. Extinction ratios of better than 10,000 are obtained for the glass-based WGPs. Two simulation packages are also employed to understand the effects of pitch, aluminum thickness, and pattern defectivity on the optical performance of the WGP devices. It is determined that the WGPs can be influenced by both clear and opaque defects in the gratings; however, the defect densities are relaxed relative to the requirements of a high-density semiconductor device.
NASA Astrophysics Data System (ADS)
Guidetti, Roberto; Tiziana, Altiero; Cesari, Michele; Rizzo, Angela Maria; Bertolani, Roberto; Galletta, Giuseppe; Dalessandro, Maurizio; Rebecchi, Lorena
Extreme habitats are highly selective and can host only living organisms possessing specific adaptations to stressors. Among extreme habitats, space environment has particular charac-teristics of radiations, vacuum, microgravity and temperature, which induce rapid changes in living systems. Consequently, the response of multicellular complex organisms, able to colo-nize extreme environments, to space stresses can give very useful information on the ability to withstand a single stress or stress combinations. This knowledge on changes in living systems in space, with their similarity to the ageing processes, offers the opportunity to improve human life both on Earth and in space. Even though experimentation in space has often been carried out using unicellular organisms, multicellular organisms are very relevant in order to develop the appropriate countermeasures to avoid the risks imposed by environmental space in humans. The little attention received by multicellular organisms is probably due, other than to difficul-ties in the manipulation of biological materials in space, to the presence of only few organisms with the potential to tolerate environmental space stresses. Among them, tardigrades are small invertebrates representing an attractive animal model to study adaptive strategies for surviving extreme environments, including space environment. Tardigrades are little known microscopic aquatic animals (250-800 m in body length) distributed in different environments (from the deep sea to high mountains and deserts all over the world), and frequently inhabiting very unstable and unpredictable habitats (e.g. interstices of mosses, lichens, leaf litter, freshwater ponds, cryoconite holes). Their ability to live in the extreme environments is related to a wide variety of their life histories and adaptive strategies. A widespread and crucial strategy is cryptobiosis, a form of quiescence. It includes strategies such as anhydrobiosis and cryobiosis, characterized by a complete or almost complete metabolic standstill. The ability of tardigrades to colonize terrestrial habitats is linked to their well known ability to enter anhydrobiosis when their habi-tat desiccates. Tardigrades survive dehydration by entering a highly stable state of suspended animation due to complete desiccation (¿ 95Results on tardigrades open a window on the fu-ture perspective in astrobiology and in their applications. The discovery and identification of metabolites naturally synthesized by tardigrades to perform a remarkable protection against the damages to cellular components and DNA due to desiccation, radiation, microgravity and oxidation stresses, will be used to define the countermeasures to protect sensitive organisms, including humans, not naturally able to withstand extreme stresses under space conditions, for the future long-term explorations of our solar system, including Mars.
Individual Differences in Adaptability to Isolated, Confined, and Extreme Environments.
Bartone, Paul T; Krueger, Gerald P; Bartone, Jocelyn V
2018-06-01
Future deep space missions will expose astronauts to more intense stressors than previously encountered. Isolation will be greater and more prolonged, living and work areas more confined, and communications and resupply channels to Earth longer and less reliable. Astronauts will need to function more autonomously, with less guidance and support from Earth. Thus, it is important to select and train astronauts who can adapt and function effectively under extreme and variable conditions. In order to identify factors linked to individual adaptability, we conducted a systematic review of the literature on cognitive and behavioral adaptation to isolated, confined, and extreme (ICE) environments. We searched PubMed, Embase, Web of Science, and PsychINFO databases for studies addressing individual adaptability to ICE environments. Studies were rated for quality and fidelity to long-duration space missions and key results extracted. There were 73 studies that met all inclusion criteria. Adaptability attributes for ICE environments include intelligence, emotional stability, self-control, openness, achievement facets of conscientiousness, optimism, mastery, introversion, hardiness, task-oriented coping, past experience, low need for social support, and adequate sleep. This review identifies individual factors linked to adaptability under ICE conditions. Further studies are needed to verify causal directions and determine the relative importance of these factors.Bartone PT, Krueger GP, Bartone JV. Individual differences in adaptability to isolated, confined, and extreme environments. Aerosp Med Hum Perform. 2018; 89(6):536-546.
Wireless Sensor Applications in Extreme Aeronautical Environments
NASA Technical Reports Server (NTRS)
Wilson, William C.; Atkinson, Gary M.
2013-01-01
NASA aeronautical programs require rigorous ground and flight testing. Many of the testing environments can be extremely harsh. These environments include cryogenic temperatures and high temperatures (greater than 1500 C). Temperature, pressure, vibration, ionizing radiation, and chemical exposure may all be part of the harsh environment found in testing. This paper presents a survey of research opportunities for universities and industry to develop new wireless sensors that address anticipated structural health monitoring (SHM) and testing needs for aeronautical vehicles. Potential applications of passive wireless sensors for ground testing and high altitude aircraft operations are presented. Some of the challenges and issues of the technology are also presented.
Extreme Environment Basing:Contingency Basing in Dense Urban and Megacity Environments
2016-05-24
the placement of a U.S. military contingency base. As stated above, the consideration given to the volume of displaced people caused by the base camp...population density , Dhaka, Bangladesh ........................... 29 B-1 The base camp development planning process...urban areas are not incredibly dense, a great many are. These places represent the extreme end of the urban spectrum for population density and city
Chenjie Huang; Y.L. Lin; M.L. Kaplan; Joseph J.J. Charney
2009-01-01
This study has employed both observational data and numerical simulation results to diagnose the synoptic-scale and mesoscale environments conducive to forest fires during the October 2003 extreme fire event in southern California. A three-stage process is proposed to illustrate the coupling of the synoptic-scale forcing that is evident from the observations,...
Life in extreme environments: how will humans perform on Mars?
NASA Technical Reports Server (NTRS)
Newman, D. J.
2000-01-01
This review of astronaut extravehicular activity (EVA) and the details of American and Soviet/Russian spacesuit design focuses on design recommendations to enhance astronaut safety and effectiveness. Innovative spacesuit design is essential, given the challenges of future exploration-class missions in which astronauts will be called upon to perform increasingly complex and physically demanding tasks in the extreme environments of microgravity and partial gravity.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 27 2010-07-01 2010-07-01 false Which threshold planning quantity do I use for an extremely hazardous substance present at my facility in solid form? 355.15 Section 355.15 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SUPERFUND, EMERGENCY PLANNING, AND COMMUNITY RIGHT-TO-KNOW PROGRAMS EMERGENCY...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 29 2012-07-01 2012-07-01 false Which threshold planning quantity do I use for an extremely hazardous substance present at my facility in solid form? 355.15 Section 355.15 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SUPERFUND, EMERGENCY PLANNING, AND COMMUNITY RIGHT-TO-KNOW PROGRAMS EMERGENCY...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 28 2011-07-01 2011-07-01 false Which threshold planning quantity do I use for an extremely hazardous substance present at my facility in solid form? 355.15 Section 355.15 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SUPERFUND, EMERGENCY PLANNING, AND COMMUNITY RIGHT-TO-KNOW PROGRAMS EMERGENCY...
NASA Astrophysics Data System (ADS)
Kitazato, Hiroshi; Fujikura, Katsunori; Sumida, Paulo G. Y.; Pellizari, Vivian H.; Perez, Jose Angel
2017-12-01
The deep sea comprises a series of extreme environments, characterized by low temperatures, high hydraulic pressure, the virtual absence of sunlight, and the scarcity of organic nutrients. High hydraulic pressure prevents human access to these environments without using human-occupied submersibles (HOVs), landers or other instruments. Unlike the extreme outer space environments, visited by hundreds of astronauts, only three humans have accessed to the deepest point of the planet.
Energy and water in aestivating amphibians.
Carvalho, José E; Navas, Carlos A; Pereira, Isabel C
2010-01-01
The physiological mechanisms, behavioral adjustments, and ecological associations that allow animal species to live in extreme environments have evoked the attention of many zoologists. Often, extreme environments are defined as those believed to be limiting to life in terms of water, energetic availability, and temperature. These three elements seem extreme in a number of arid and semi-arid settings that even so have been colonized by amphibians. Because this taxon is usually seen as the quintessential water-dependent ectotherm tetrapods, their presence in a number of semi-arid environments poses a number of intriguing questions regarding microhabitat choice and physiological plasticity, particularly regarding the ecological and physiological correlates of behaviors granting avoidance of the harshest conditions of semi-arid environments. Such avoidance states, generally associated to the concept of aestivation, are currently seen as a diverse and complex phenomena varying from species to species and involving numerous behavioral and metabolic adjustments that enhance survival during the drought. This chapter reviews the physiological ecology of anuran aestivation, mainly from the perspective of water and energy balance.
Dinocyst taphonomy, impact craters, cyst ghosts, and the Paleocene-Eocene thermal maximum (PETM)
Edwards, Lucy E.
2012-01-01
Dinocysts recovered from sediments related to the Chesapeake Bay impact structure in Virginia and the earliest Eocene suboxic environment in Maryland show strange and intriguing details of preservation. Features such as curled processes, opaque debris, breakage, microborings and cyst ghosts, among others, invite speculation about catastrophic depositional processes, rapid burial and biological and chemical decay. Selected specimens from seven cores taken in the coastal plain of Virginia and Maryland show abnormal preservation features in various combinations that merit illustration, description, discussion and further study. Although the depositional environments described are extreme, many of the features discussed are known from, or could be found in, other environments. These environments will show both similarities to and differences from the extreme environments here.
The operation of 0.35 μm partially depleted SOI CMOS technology in extreme environments
NASA Astrophysics Data System (ADS)
Li, Ying; Niu, Guofu; Cressler, John D.; Patel, Jagdish; Liu, S. T.; Reed, Robert A.; Mojarradi, Mohammad M.; Blalock, Benjamin J.
2003-06-01
We evaluate the usefulness of partially depleted SOI CMOS devices fabricated in a 0.35 μm technology on UNIBOND material for electronics applications requiring robust operation under extreme environment conditions consisting of low and/or high temperature, and under substantial radiation exposure. The threshold voltage, effective mobility, and the impact ionization parameters were determined across temperature for both the nFETs and the pFETs. The radiation response was characterized using threshold voltage shifts of both the front-gate and back-gate transistors. These results suggest that this 0.35 μm partially depleted SOI CMOS technology is suitable for operation across a wide range of extreme environment conditions consisting of: cryogenic temperatures down to 86 K, elevated temperatures up to 573 K, and under radiation exposure to 1.3 Mrad(Si) total dose.
ERIC Educational Resources Information Center
Morgan, Frank T.
1977-01-01
After citing reasons for the use of flextime, a case study is presented which indicates positive effects of flextime scheduling for employees--work satisfaction, better performance, and more personal life--and the company. (SH)
Extreme-Environment Silicon-Carbide (SiC) Wireless Sensor Suite
NASA Technical Reports Server (NTRS)
Yang, Jie
2015-01-01
Phase II objectives: Develop an integrated silicon-carbide wireless sensor suite capable of in situ measurements of critical characteristics of NTP engine; Compose silicon-carbide wireless sensor suite of: Extreme-environment sensors center, Dedicated high-temperature (450 deg C) silicon-carbide electronics that provide power and signal conditioning capabilities as well as radio frequency modulation and wireless data transmission capabilities center, An onboard energy harvesting system as a power source.
Environmental hazards, hot, cold, altitude, and sun.
Dhillon, Sundeep
2012-09-01
There has been an increase in both recreational and adventure travel to extreme environments. Humans can successfully acclimatize to and perform reasonably well in extreme environments, provided that sufficient time is given for acclimatization (where possible) and that they use appropriate behavior. This is aided by a knowledge of the problems likely to be encountered and their prevention, recognition, and treatment. Crown Copyright © 2012. Published by Elsevier Inc. All rights reserved.
Distributed Motor Controller (DMC) for Operation in Extreme Environments
NASA Technical Reports Server (NTRS)
McKinney, Colin M.; Yager, Jeremy A.; Mojarradi, Mohammad M.; Some, Rafi; Sirota, Allen; Kopf, Ted; Stern, Ryan; Hunter, Don
2012-01-01
This paper presents an extreme environment capable Distributed Motor Controller (DMC) module suitable for operation with a distributed architecture of future spacecraft systems. This motor controller is designed to be a bus-based electronics module capable of operating a single Brushless DC motor in extreme space environments: temperature (-120 C to +85 C required, -180 C to +100 C stretch goal); radiation (>;20K required, >;100KRad stretch goal); >;360 cycles of operation. Achieving this objective will result in a scalable modular configuration for motor control with enhanced reliability that will greatly lower cost during the design, fabrication and ATLO phases of future missions. Within the heart of the DMC lies a pair of cold-capable Application Specific Integrated Circuits (ASICs) and a Field Programmable Gate Array (FPGA) that enable its miniaturization and operation in extreme environments. The ASICs are fabricated in the IBM 0.5 micron Silicon Germanium (SiGe) BiCMOS process and are comprised of Analog circuitry to provide telemetry information, sensor interface, and health and status of DMC. The FPGA contains logic to provide motor control, status monitoring and spacecraft interface. The testing and characterization of these ASICs have yielded excellent functionality in cold temperatures (-135 C). The DMC module has demonstrated successful operation of a motor at temperature.
Extreme Science (LBNL Science at the Theater)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ajo-Franklin, Caroline; Klein, Spencer; Minor, Andrew
On Feb. 27, 2012 at the Berkeley Repertory Theatre, four Berkeley Lab scientists presented talks related to extreme science - and what it means to you. Topics include: Neutrino hunting in Antarctica. Learn why Spencer Klein goes to the ends of the Earth to search for these ghostly particles. From Chernobyl to Central Asia, Tamas Torok travels the globe to study microbial diversity in extreme environments. Andrew Minor uses the world's most advanced electron microscopes to explore materials at ultrahigh stresses and in harsh environments. And microbes that talk to computers? Caroline Ajo-Franklin is pioneering cellular-electrical connections that could helpmore » transform sunlight into fuel.« less
Terrestrial Applications of Extreme Environment Stirling Space Power Systems
NASA Technical Reports Server (NTRS)
Dyson, Rodger. W.
2012-01-01
NASA has been developing power systems capable of long-term operation in extreme environments such as the surface of Venus. This technology can use any external heat source to efficiently provide electrical power and cooling; and it is designed to be extremely efficient and reliable for extended space missions. Terrestrial applications include: use in electric hybrid vehicles; distributed home co-generation/cooling; and quiet recreational vehicle power generation. This technology can reduce environmental emissions, petroleum consumption, and noise while eliminating maintenance and environmental damage from automotive fluids such as oil lubricants and air conditioning coolant. This report will provide an overview of this new technology and its applications.
Microbial Diversity in Extreme Marine Habitats and Their Biomolecules
Poli, Annarita; Finore, Ilaria; Romano, Ida; Gioiello, Alessia; Lama, Licia; Nicolaus, Barbara
2017-01-01
Extreme marine environments have been the subject of many studies and scientific publications. For many years, these environmental niches, which are characterized by high or low temperatures, high-pressure, low pH, high salt concentrations and also two or more extreme parameters in combination, have been thought to be incompatible to any life forms. Thanks to new technologies such as metagenomics, it is now possible to detect life in most extreme environments. Starting from the discovery of deep sea hydrothermal vents up to the study of marine biodiversity, new microorganisms have been identified, and their potential uses in several applied fields have been outlined. Thermophile, halophile, alkalophile, psychrophile, piezophile and polyextremophile microorganisms have been isolated from these marine environments; they proliferate thanks to adaptation strategies involving diverse cellular metabolic mechanisms. Therefore, a vast number of new biomolecules such as enzymes, polymers and osmolytes from the inhabitant microbial community of the sea have been studied, and there is a growing interest in the potential returns of several industrial production processes concerning the pharmaceutical, medical, environmental and food fields. PMID:28509857
NASA Astrophysics Data System (ADS)
Xu, S.; Curry, S.; Mitchell, D. L.; Luhmann, J. G.; Lillis, R. J.; Dong, C.
2017-12-01
Characterizing how the solar cycle affects the physics of the Mars-solar wind interaction can improve our understanding of Mars' atmospheric evolution and the plasma environment at Mars. In particular, solar transient events such as Interplanetary Coronal Mass Ejections (ICMEs) and Stream Interaction Regions (SIRs) significantly change the solar-wind interaction, including the magnetic topology and ion acceleration. However, both the Mars Express and Mars Atmosphere Volatile EvolutioN (MAVEN) missions have encountered relatively few extreme solar transient events due to the recent low solar activity (2004-2017). In contrast, Mars Global Surveyor (MGS) was operating during a relatively active solar maximum (1999-2003). Based on new results from MAVEN, this study reanalyzes MGS data to better understand how the Martian plasma environment responds to extreme solar events. In particular, we aim to investigate how the magnetic topology during these extreme events differs from the topology during quiet times. We conduct orbit comparisons of the magnetic topology inferred from MGS electron pitch angle distributions during quiet periods and extreme events to determine how the open and closed field patterns respond to extreme events.