  1. Neuronal basis of covert spatial attention in the frontal eye field.

    PubMed

    Thompson, Kirk G; Biscoe, Keri L; Sato, Takashi R

    2005-10-12

    The influential "premotor theory of attention" proposes that developing oculomotor commands mediate covert visual spatial attention. A likely source of this attentional bias is the frontal eye field (FEF), an area of the frontal cortex involved in converting visual information into saccade commands. We investigated the link between FEF activity and covert spatial attention by recording from FEF visual and saccade-related neurons in monkeys performing covert visual search tasks without eye movements. Here we show that the source of attention signals in the FEF is enhanced activity of visually responsive neurons. At the time attention is allocated to the visual search target, nonvisually responsive saccade-related movement neurons are inhibited. Therefore, in the FEF, spatial attention signals are independent of explicit saccade command signals. We propose that spatially selective activity in FEF visually responsive neurons corresponds to the mental spotlight of attention via modulation of ongoing visual processing.

  2. Eye Movement Suppression Interferes with Construction of Object-Centered Spatial Reference Frames in Working Memory

    ERIC Educational Resources Information Center

    Wallentin, Mikkel; Kristensen, Line Burholt; Olsen, Jacob Hedeager; Nielsen, Andreas Hojlund

    2011-01-01

    The brain's frontal eye fields (FEF), responsible for eye movement control, are known to be involved in spatial working memory (WM). In a previous fMRI experiment (Wallentin, Roepstorff & Burgess, Neuropsychologia, 2008) it was found that FEF activation was primarily related to the formation of an object-centered, rather than egocentric, spatial…

  3. Upward gaze and head deviation with frontal eye field stimulation.

    PubMed

    Kaiboriboon, Kitti; Lüders, Hans O; Miller, Jonathan P; Leigh, R John

    2012-03-01

    Using electrical stimulation to the deep, most caudal part of the right frontal eye field (FEF), we demonstrate a novel pattern of vertical (upward) eye movement that was previously only thought possible by stimulating both frontal eye fields simultaneously. If stimulation was started when the subject looked laterally, the initial eye movement was back to the midline, followed by upward deviation. Our finding challenges current view of topological organisation in the human FEF and may have general implications for concepts of topological organisation of the motor cortex, since sustained stimulation also induced upward head movements as a component of the vertical gaze shift. [Published with video sequences].

  4. Timing of target discrimination in human frontal eye fields.

    PubMed

    O'Shea, Jacinta; Muggleton, Neil G; Cowey, Alan; Walsh, Vincent

    2004-01-01

    Frontal eye field (FEF) neurons discharge in response to behaviorally relevant stimuli that are potential targets for saccades. Distinct visual and motor processes have been dissociated in the FEF of macaque monkeys, but little is known about the visual processing capacity of FEF in humans. We used double-pulse transcranial magnetic stimulation [(d)TMS] to investigate the timing of target discrimination during visual conjunction search. We applied dual TMS pulses separated by 40 msec over the right FEF and vertex. These were applied in five timing conditions to sample separate time windows within the first 200 msec of visual processing. (d)TMS impaired search performance, reflected in reduced d' scores. This effect was limited to a time window between 40 and 80 msec after search array onset. These parameters correspond with single-cell activity in FEF that predicts monkeys' behavioral reports on hit, miss, false alarm, and correct rejection trials. Our findings demonstrate a crucial early role for human FEF in visual target discrimination that is independent of saccade programming.

  5. Orienting Auditory Spatial Attention Engages Frontal Eye Fields and Medial Occipital Cortex in Congenitally Blind Humans

    PubMed Central

    Garg, Arun; Schwartz, Daniel; Stevens, Alexander A.

    2007-01-01

    What happens in vision related cortical areas when congenitally blind (CB) individuals orient attention to spatial locations? Previous neuroimaging of sighted individuals has found overlapping activation in a network of frontoparietal areas including frontal eye-fields (FEF), during both overt (with eye movement) and covert (without eye movement) shifts of spatial attention. Since voluntary eye movement planning seems irrelevant in CB, their FEF neurons should be recruited for alternative functions if their attentional role in sighted individuals is only due to eye movement planning. Recent neuroimaging of the blind has also reported activation in medial occipital areas, normally associated with visual processing, during a diverse set of non-visual tasks, but their response to attentional shifts remains poorly understood. Here, we used event-related fMRI to explore FEF and medial occipital areas in CB individuals and sighted controls with eyes closed (SC) performing a covert attention orienting task, using endogenous verbal cues and spatialized auditory targets. We found robust stimulus-locked FEF activation of all CB subjects, similar but stronger than in SC, suggesting that FEF plays a role in endogenous orienting of covert spatial attention even in individuals in whom voluntary eye movements are irrelevant. We also found robust activation in bilateral medial occipital cortex in CB but not in SC subjects. The response decreased below baseline following endogenous verbal cues but increased following auditory targets, suggesting that the medial occipital area in CB does not directly engage during cued orienting of attention but may be recruited for processing of spatialized auditory targets. PMID:17397882

  6. The frontal eye fields limit the capacity of visual short-term memory in rhesus monkeys.

    PubMed

    Lee, Kyoung-Min; Ahn, Kyung-Ha

    2013-01-01

    The frontal eye fields (FEF) in rhesus monkeys have been implicated in visual short-term memory (VSTM) as well as control of visual attention. Here we examined the importance of the area in the VSTM capacity and the relationship between VSTM and attention, using the chemical inactivation technique and multi-target saccade tasks with or without the need of target-location memory. During FEF inactivation, serial saccades to targets defined by color contrast were unaffected, but saccades relying on short-term memory were impaired when the target count was at the capacity limit of VSTM. The memory impairment was specific to the FEF-coded retinotopic locations, and subject to competition among targets distributed across visual fields. These results together suggest that the FEF plays a crucial role during the entry of information into VSTM, by enabling attention deployment on targets to be remembered. In this view, the memory capacity results from the limited availability of attentional resources provided by FEF: The FEF can concurrently maintain only a limited number of activations to register the targets into memory. When lesions render part of the area unavailable for activation, the number would decrease, further reducing the capacity of VSTM.

  7. The vestibular-related frontal cortex and its role in smooth-pursuit eye movements and vestibular-pursuit interactions

    PubMed Central

    Fukushima, Junko; Akao, Teppei; Kurkin, Sergei; Kaneko, Chris R.S.; Fukushima, Kikuro

    2006-01-01

    In order to see clearly when a target is moving slowly, primates with high acuity foveae use smooth-pursuit and vergence eye movements. The former rotates both eyes in the same direction to track target motion in frontal planes, while the latter rotates left and right eyes in opposite directions to track target motion in depth. Together, these two systems pursue targets precisely and maintain their images on the foveae of both eyes. During head movements, both systems must interact with the vestibular system to minimize slip of the retinal images. The primate frontal cortex contains two pursuit-related areas; the caudal part of the frontal eye fields (FEF) and supplementary eye fields (SEF). Evoked potential studies have demonstrated vestibular projections to both areas and pursuit neurons in both areas respond to vestibular stimulation. The majority of FEF pursuit neurons code parameters of pursuit such as pursuit and vergence eye velocity, gaze velocity, and retinal image motion for target velocity in frontal and depth planes. Moreover, vestibular inputs contribute to the predictive pursuit responses of FEF neurons. In contrast, the majority of SEF pursuit neurons do not code pursuit metrics and many SEF neurons are reported to be active in more complex tasks. These results suggest that FEF- and SEF-pursuit neurons are involved in different aspects of vestibular-pursuit interactions and that eye velocity coding of SEF pursuit neurons is specialized for the task condition. PMID:16917164

  8. A Causal Role for the Cortical Frontal Eye Fields in Microsaccade Deployment

    PubMed Central

    Dash, Suryadeep; Lomber, Stephen G.

    2016-01-01

    Microsaccades aid vision by helping to strategically sample visual scenes. Despite the importance of these small eye movements, no cortical area has ever been implicated in their generation. Here, we used unilateral and bilateral reversible inactivation of the frontal eye fields (FEF) to identify a cortical drive for microsaccades. Unexpectedly, FEF inactivation altered microsaccade metrics and kinematics. Such inactivation also impaired microsaccade deployment following peripheral cue onset, regardless of cue side or inactivation configuration. Our results demonstrate that the FEF provides critical top-down drive for microsaccade generation, particularly during the recovery of microsaccades after disruption by sensory transients. Our results constitute the first direct evidence, to our knowledge, for the contribution of any cortical area to microsaccade generation, and they provide a possible substrate for how cognitive processes can influence the strategic deployment of microsaccades. PMID:27509130

  9. A Causal Role for the Cortical Frontal Eye Fields in Microsaccade Deployment.

    PubMed

    Peel, Tyler R; Hafed, Ziad M; Dash, Suryadeep; Lomber, Stephen G; Corneil, Brian D

    2016-08-01

    Microsaccades aid vision by helping to strategically sample visual scenes. Despite the importance of these small eye movements, no cortical area has ever been implicated in their generation. Here, we used unilateral and bilateral reversible inactivation of the frontal eye fields (FEF) to identify a cortical drive for microsaccades. Unexpectedly, FEF inactivation altered microsaccade metrics and kinematics. Such inactivation also impaired microsaccade deployment following peripheral cue onset, regardless of cue side or inactivation configuration. Our results demonstrate that the FEF provides critical top-down drive for microsaccade generation, particularly during the recovery of microsaccades after disruption by sensory transients. Our results constitute the first direct evidence, to our knowledge, for the contribution of any cortical area to microsaccade generation, and they provide a possible substrate for how cognitive processes can influence the strategic deployment of microsaccades.

  10. Similar prevalence and magnitude of auditory-evoked and visually evoked activity in the frontal eye fields: implications for multisensory motor control.

    PubMed

    Caruso, Valeria C; Pages, Daniel S; Sommer, Marc A; Groh, Jennifer M

    2016-06-01

    Saccadic eye movements can be elicited by more than one type of sensory stimulus. This implies substantial transformations of signals originating in different sense organs as they reach a common motor output pathway. In this study, we compared the prevalence and magnitude of auditory- and visually evoked activity in a structure implicated in oculomotor processing, the primate frontal eye fields (FEF). We recorded from 324 single neurons while 2 monkeys performed delayed saccades to visual or auditory targets. We found that 64% of FEF neurons were active on presentation of auditory targets and 87% were active during auditory-guided saccades, compared with 75 and 84% for visual targets and saccades. As saccade onset approached, the average level of population activity in the FEF became indistinguishable on visual and auditory trials. FEF activity was better correlated with the movement vector than with the target location for both modalities. In summary, the large proportion of auditory-responsive neurons in the FEF, the similarity between visual and auditory activity levels at the time of the saccade, and the strong correlation between the activity and the saccade vector suggest that auditory signals undergo tailoring to match roughly the strength of visual signals present in the FEF, facilitating accessing of a common motor output pathway. Copyright © 2016 the American Physiological Society.

  11. Contribution of the frontal eye field to gaze shifts in the head-unrestrained rhesus monkey: neuronal activity.

    PubMed

    Knight, T A

    2012-12-06

    The frontal eye field (FEF) has a strong influence on saccadic eye movements with the head restrained. With the head unrestrained, eye saccades combine with head movements to produce large gaze shifts, and microstimulation of the FEF evokes both eye and head movements. To test whether the dorsomedial FEF provides commands for the entire gaze shift or its separate eye and head components, we recorded extracellular single-unit activity in monkeys trained to make large head-unrestrained gaze shifts. We recorded 80 units active during gaze shifts, and closely examined 26 of these that discharged a burst of action potentials that preceded horizontal gaze movements. These units were movement or visuomovement related and most exhibited open movement fields with respect to amplitude. To reveal the relations of burst parameters to gaze, eye, and/or head movement metrics, we used behavioral dissociations of gaze, eye, and head movements and linear regression analyses. The burst number of spikes (NOS) was strongly correlated with movement amplitude and burst temporal parameters were strongly correlated with movement temporal metrics for eight gaze-related burst neurons and five saccade-related burst neurons. For the remaining 13 neurons, the NOS was strongly correlated with the head movement amplitude, but burst temporal parameters were most strongly correlated with eye movement temporal metrics (head-eye-related burst neurons, HEBNs). These results suggest that FEF units do not encode a command for the unified gaze shift only; instead, different units may carry signals related to the overall gaze shift or its eye and/or head components. Moreover, the HEBNs exhibit bursts whose magnitude and timing may encode a head displacement signal and a signal that influences the timing of the eye saccade, thereby serving as a mechanism for coordinating the eye and head movements of a gaze shift. Copyright © 2012 IBRO. Published by Elsevier Ltd. All rights reserved.

  12. Transition from Target to Gaze Coding in Primate Frontal Eye Field during Memory Delay and Memory-Motor Transformation.

    PubMed

    Sajad, Amirsaman; Sadeh, Morteza; Yan, Xiaogang; Wang, Hongying; Crawford, John Douglas

    2016-01-01

    The frontal eye fields (FEFs) participate in both working memory and sensorimotor transformations for saccades, but their role in integrating these functions through time remains unclear. Here, we tracked FEF spatial codes through time using a novel analytic method applied to the classic memory-delay saccade task. Three-dimensional recordings of head-unrestrained gaze shifts were made in two monkeys trained to make gaze shifts toward briefly flashed targets after a variable delay (450-1500 ms). A preliminary analysis of visual and motor response fields in 74 FEF neurons eliminated most potential models for spatial coding at the neuron population level, as in our previous study (Sajad et al., 2015). We then focused on the spatiotemporal transition from an eye-centered target code (T; preferred in the visual response) to an eye-centered intended gaze position code (G; preferred in the movement response) during the memory delay interval. We treated neural population codes as a continuous spatiotemporal variable by dividing the space spanning T and G into intermediate T-G models and dividing the task into discrete steps through time. We found that FEF delay activity, especially in visuomovement cells, progressively transitions from T through intermediate T-G codes that approach, but do not reach, G. This was followed by a final discrete transition from these intermediate T-G delay codes to a "pure" G code in movement cells without delay activity. These results demonstrate that FEF activity undergoes a series of sensory-memory-motor transformations, including a dynamically evolving spatial memory signal and an imperfect memory-to-motor transformation.

  13. Disrupting frontal eye-field activity impairs memory recall.

    PubMed

    Wantz, Andrea L; Martarelli, Corinna S; Cazzoli, Dario; Kalla, Roger; Müri, René; Mast, Fred W

    2016-04-13

    A large body of research demonstrated that participants preferably look back to the encoding location when retrieving visual information from memory. However, the role of this 'looking back to nothing' is still debated. The goal of the present study was to extend this line of research by examining whether an important area in the cortical representation of the oculomotor system, the frontal eye field (FEF), is involved in memory retrieval. To interfere with the activity of the FEF, we used inhibitory continuous theta burst stimulation (cTBS). Before stimulation was applied, participants encoded a complex scene and performed a short-term (immediately after encoding) or long-term (after 24 h) recall task, just after cTBS over the right FEF or sham stimulation. cTBS did not affect overall performance, but stimulation and statement type (object vs. location) interacted. cTBS over the right FEF tended to impair object recall sensitivity, whereas there was no effect on location recall sensitivity. These findings suggest that the FEF is involved in retrieving object information from scene memory, supporting the hypothesis that the oculomotor system contributes to memory recall.

  14. Vestibular-Related Frontal Cortical Areas and Their Roles in Smooth-Pursuit Eye Movements: Representation of Neck Velocity, Neck-Vestibular Interactions, and Memory-Based Smooth-Pursuit

    PubMed Central

    Fukushima, Kikuro; Fukushima, Junko; Warabi, Tateo

    2011-01-01

    Smooth-pursuit eye movements are voluntary responses to small slow-moving objects in the fronto-parallel plane. They evolved in primates, who possess high-acuity foveae, to ensure clear vision about the moving target. The primate frontal cortex contains two smooth-pursuit related areas; the caudal part of the frontal eye fields (FEF) and the supplementary eye fields (SEF). Both areas receive vestibular inputs. We review functional differences between the two areas in smooth-pursuit. Most FEF pursuit neurons signal pursuit parameters such as eye velocity and gaze-velocity, and are involved in canceling the vestibulo-ocular reflex by linear addition of vestibular and smooth-pursuit responses. In contrast, gaze-velocity signals are rarely represented in the SEF. Most FEF pursuit neurons receive neck velocity inputs, while discharge modulation during pursuit and trunk-on-head rotation adds linearly. Linear addition also occurs between neck velocity responses and vestibular responses during head-on-trunk rotation in a task-dependent manner. During cross-axis pursuit–vestibular interactions, vestibular signals effectively initiate predictive pursuit eye movements. Most FEF pursuit neurons discharge during the interaction training after the onset of pursuit eye velocity, making their involvement unlikely in the initial stages of generating predictive pursuit. Comparison of representative signals in the two areas and the results of chemical inactivation during a memory-based smooth-pursuit task indicate they have different roles; the SEF plans smooth-pursuit including working memory of motion–direction, whereas the caudal FEF generates motor commands for pursuit eye movements. Patients with idiopathic Parkinson’s disease were asked to perform this task, since impaired smooth-pursuit and visual working memory deficit during cognitive tasks have been reported in most patients. Preliminary results suggested specific roles of the basal ganglia in memory-based smooth-pursuit. PMID:22174706

  15. Transition from Target to Gaze Coding in Primate Frontal Eye Field during Memory Delay and Memory–Motor Transformation123

    PubMed Central

    Sajad, Amirsaman; Sadeh, Morteza; Yan, Xiaogang; Wang, Hongying

    2016-01-01

    Abstract The frontal eye fields (FEFs) participate in both working memory and sensorimotor transformations for saccades, but their role in integrating these functions through time remains unclear. Here, we tracked FEF spatial codes through time using a novel analytic method applied to the classic memory-delay saccade task. Three-dimensional recordings of head-unrestrained gaze shifts were made in two monkeys trained to make gaze shifts toward briefly flashed targets after a variable delay (450-1500 ms). A preliminary analysis of visual and motor response fields in 74 FEF neurons eliminated most potential models for spatial coding at the neuron population level, as in our previous study (Sajad et al., 2015). We then focused on the spatiotemporal transition from an eye-centered target code (T; preferred in the visual response) to an eye-centered intended gaze position code (G; preferred in the movement response) during the memory delay interval. We treated neural population codes as a continuous spatiotemporal variable by dividing the space spanning T and G into intermediate T–G models and dividing the task into discrete steps through time. We found that FEF delay activity, especially in visuomovement cells, progressively transitions from T through intermediate T–G codes that approach, but do not reach, G. This was followed by a final discrete transition from these intermediate T–G delay codes to a “pure” G code in movement cells without delay activity. These results demonstrate that FEF activity undergoes a series of sensory–memory–motor transformations, including a dynamically evolving spatial memory signal and an imperfect memory-to-motor transformation. PMID:27092335

  16. A hierarchy of timescales explains distinct effects of local inhibition of primary visual cortex and frontal eye fields

    PubMed Central

    Cocchi, Luca; Sale, Martin V; L Gollo, Leonardo; Bell, Peter T; Nguyen, Vinh T; Zalesky, Andrew; Breakspear, Michael; Mattingley, Jason B

    2016-01-01

    Within the primate visual system, areas at lower levels of the cortical hierarchy process basic visual features, whereas those at higher levels, such as the frontal eye fields (FEF), are thought to modulate sensory processes via feedback connections. Despite these functional exchanges during perception, there is little shared activity between early and late visual regions at rest. How interactions emerge between regions encompassing distinct levels of the visual hierarchy remains unknown. Here we combined neuroimaging, non-invasive cortical stimulation and computational modelling to characterize changes in functional interactions across widespread neural networks before and after local inhibition of primary visual cortex or FEF. We found that stimulation of early visual cortex selectively increased feedforward interactions with FEF and extrastriate visual areas, whereas identical stimulation of the FEF decreased feedback interactions with early visual areas. Computational modelling suggests that these opposing effects reflect a fast-slow timescale hierarchy from sensory to association areas. DOI: http://dx.doi.org/10.7554/eLife.15252.001 PMID:27596931

  17. A hierarchy of timescales explains distinct effects of local inhibition of primary visual cortex and frontal eye fields.

    PubMed

    Cocchi, Luca; Sale, Martin V; L Gollo, Leonardo; Bell, Peter T; Nguyen, Vinh T; Zalesky, Andrew; Breakspear, Michael; Mattingley, Jason B

    2016-09-06

    Within the primate visual system, areas at lower levels of the cortical hierarchy process basic visual features, whereas those at higher levels, such as the frontal eye fields (FEF), are thought to modulate sensory processes via feedback connections. Despite these functional exchanges during perception, there is little shared activity between early and late visual regions at rest. How interactions emerge between regions encompassing distinct levels of the visual hierarchy remains unknown. Here we combined neuroimaging, non-invasive cortical stimulation and computational modelling to characterize changes in functional interactions across widespread neural networks before and after local inhibition of primary visual cortex or FEF. We found that stimulation of early visual cortex selectively increased feedforward interactions with FEF and extrastriate visual areas, whereas identical stimulation of the FEF decreased feedback interactions with early visual areas. Computational modelling suggests that these opposing effects reflect a fast-slow timescale hierarchy from sensory to association areas.

  18. Frontal eye field, where art thou? Anatomy, function, and non-invasive manipulation of frontal regions involved in eye movements and associated cognitive operations

    PubMed Central

    Vernet, Marine; Quentin, Romain; Chanes, Lorena; Mitsumasu, Andres; Valero-Cabré, Antoni

    2014-01-01

    The planning, control and execution of eye movements in 3D space relies on a distributed system of cortical and subcortical brain regions. Within this network, the Eye Fields have been described in animals as cortical regions in which electrical stimulation is able to trigger eye movements and influence their latency or accuracy. This review focuses on the Frontal Eye Field (FEF) a “hub” region located in Humans in the vicinity of the pre-central sulcus and the dorsal-most portion of the superior frontal sulcus. The straightforward localization of the FEF through electrical stimulation in animals is difficult to translate to the healthy human brain, particularly with non-invasive neuroimaging techniques. Hence, in the first part of this review, we describe attempts made to characterize the anatomical localization of this area in the human brain. The outcome of functional Magnetic Resonance Imaging (fMRI), Magneto-encephalography (MEG) and particularly, non-invasive mapping methods such a Transcranial Magnetic Stimulation (TMS) are described and the variability of FEF localization across individuals and mapping techniques are discussed. In the second part of this review, we will address the role of the FEF. We explore its involvement both in the physiology of fixation, saccade, pursuit, and vergence movements and in associated cognitive processes such as attentional orienting, visual awareness and perceptual modulation. Finally in the third part, we review recent evidence suggesting the high level of malleability and plasticity of these regions and associated networks to non-invasive stimulation. The exploratory, diagnostic, and therapeutic interest of such interventions for the modulation and improvement of perception in 3D space are discussed. PMID:25202241

  19. Persistent spatial information in the frontal eye field during object-based short-term memory.

    PubMed

    Clark, Kelsey L; Noudoost, Behrad; Moore, Tirin

    2012-08-08

    Spatial attention is known to gate entry into visual short-term memory, and some evidence suggests that spatial signals may also play a role in binding features or protecting object representations during memory maintenance. To examine the persistence of spatial signals during object short-term memory, the activity of neurons in the frontal eye field (FEF) of macaque monkeys was recorded during an object-based delayed match-to-sample task. In this task, monkeys were trained to remember an object image over a brief delay, regardless of the locations of the sample or target presentation. FEF neurons exhibited visual, delay, and target period activity, including selectivity for sample location and target location. Delay period activity represented the sample location throughout the delay, despite the irrelevance of spatial information for successful task completion. Furthermore, neurons continued to encode sample position in a variant of the task in which the matching stimulus never appeared in their response field, confirming that FEF maintains sample location independent of subsequent behavioral relevance. FEF neurons also exhibited target-position-dependent anticipatory activity immediately before target onset, suggesting that monkeys predicted target position within blocks. These results show that FEF neurons maintain spatial information during short-term memory, even when that information is irrelevant for task performance.

  20. Neurally Constrained Modeling of Perceptual Decision Making

    ERIC Educational Resources Information Center

    Purcell, Braden A.; Heitz, Richard P.; Cohen, Jeremiah Y.; Schall, Jeffrey D.; Logan, Gordon D.; Palmeri, Thomas J.

    2010-01-01

    Stochastic accumulator models account for response time in perceptual decision-making tasks by assuming that perceptual evidence accumulates to a threshold. The present investigation mapped the firing rate of frontal eye field (FEF) visual neurons onto perceptual evidence and the firing rate of FEF movement neurons onto evidence accumulation to…

  1. Frontal Eye Fields Control Attentional Modulation of Alpha and Gamma Oscillations in Contralateral Occipitoparietal Cortex

    PubMed Central

    O'Shea, Jacinta; Jensen, Ole; Bergmann, Til O.

    2015-01-01

    Covertly directing visuospatial attention produces a frequency-specific modulation of neuronal oscillations in occipital and parietal cortices: anticipatory alpha (8–12 Hz) power decreases contralateral and increases ipsilateral to attention, whereas stimulus-induced gamma (>40 Hz) power is boosted contralaterally and attenuated ipsilaterally. These modulations must be under top-down control; however, the control mechanisms are not yet fully understood. Here we investigated the causal contribution of the human frontal eye field (FEF) by combining repetitive transcranial magnetic stimulation (TMS) with subsequent magnetoencephalography. Following inhibitory theta burst stimulation to the left FEF, right FEF, or vertex, participants performed a visual discrimination task requiring covert attention to either visual hemifield. Both left and right FEF TMS caused marked attenuation of alpha modulation in the occipitoparietal cortex. Notably, alpha modulation was consistently reduced in the hemisphere contralateral to stimulation, leaving the ipsilateral hemisphere relatively unaffected. Additionally, right FEF TMS enhanced gamma modulation in left visual cortex. Behaviorally, TMS caused a relative slowing of response times to targets contralateral to stimulation during the early task period. Our results suggest that left and right FEF are causally involved in the attentional top-down control of anticipatory alpha power in the contralateral visual system, whereas a right-hemispheric dominance seems to exist for control of stimulus-induced gamma power. These findings contrast the assumption of primarily intrahemispheric connectivity between FEF and parietal cortex, emphasizing the relevance of interhemispheric interactions. The contralaterality of effects may result from a transient functional reorganization of the dorsal attention network after inhibition of either FEF. PMID:25632139

  2. Dissecting patterns of preparatory activity in the frontal eye fields during pursuit target selection.

    PubMed

    Raghavan, Ramanujan T; Joshua, Mati

    2017-10-01

    We investigated the composition of preparatory activity of frontal eye field (FEF) neurons in monkeys performing a pursuit target selection task. In response to the orthogonal motion of a large and a small reward target, monkeys initiated pursuit biased toward the direction of large reward target motion. FEF neurons exhibited robust preparatory activity preceding movement initiation in this task. Preparatory activity consisted of two components, ramping activity that was constant across target selection conditions, and a flat offset in firing rates that signaled the target selection condition. Ramping activity accounted for 50% of the variance in the preparatory activity and was linked most strongly, on a trial-by-trial basis, to pursuit eye movement latency rather than to its direction or gain. The offset in firing rates that discriminated target selection conditions accounted for 25% of the variance in the preparatory activity and was commensurate with a winner-take-all representation, signaling the direction of large reward target motion rather than a representation that matched the parameters of the upcoming movement. These offer new insights into the role that the frontal eye fields play in target selection and pursuit control. They show that preparatory activity in the FEF signals more strongly when to move rather than where or how to move and suggest that structures outside the FEF augment its contributions to the target selection process. NEW & NOTEWORTHY We used the smooth eye movement pursuit system to link between patterns of preparatory activity in the frontal eye fields and movement during a target selection task. The dominant pattern was a ramping signal that did not discriminate between selection conditions and was linked, on trial-by-trial basis, to movement latency. A weaker pattern was composed of a constant signal that discriminated between selection conditions but was only weakly linked to the movement parameters. Copyright © 2017 the American Physiological Society.

  3. Dissociable Frontal Controls during Visible and Memory-guided Eye-Tracking of Moving Targets

    PubMed Central

    Ding, Jinhong; Powell, David; Jiang, Yang

    2009-01-01

    When tracking visible or occluded moving targets, several frontal regions including the frontal eye fields (FEF), dorsal-lateral prefrontal cortex (DLPFC), and Anterior Cingulate Cortex (ACC) are involved in smooth pursuit eye movements (SPEM). To investigate how these areas play different roles in predicting future locations of moving targets, twelve healthy college students participated in a smooth pursuit task of visual and occluded targets. Their eye movements and brain responses measured by event-related functional MRI were simultaneously recorded. Our results show that different visual cues resulted in time discrepancies between physical and estimated pursuit time only when the moving dot was occluded. Visible phase velocity gain was higher than that of occlusion phase. We found bilateral FEF association with eye-movement whether moving targets are visible or occluded. However, the DLPFC and ACC showed increased activity when tracking and predicting locations of occluded moving targets, and were suppressed during smooth pursuit of visible targets. When visual cues were increasingly available, less activation in the DLPFC and the ACC was observed. Additionally, there was a significant hemisphere effect in DLPFC, where right DLPFC showed significantly increased responses over left when pursuing occluded moving targets. Correlation results revealed that DLPFC, the right DLPFC in particular, communicates more with FEF during tracking of occluded moving targets (from memory). The ACC modulates FEF more during tracking of visible targets (likely related to visual attention). Our results suggest that DLPFC and ACC modulate FEF and cortical networks differentially during visible and memory-guided eye tracking of moving targets. PMID:19434603

  4. A visual salience map in the primate frontal eye field.

    PubMed

    Thompson, Kirk G; Bichot, Narcisse P

    2005-01-01

    Models of attention and saccade target selection propose that within the brain there is a topographic map of visual salience that combines bottom-up and top-down influences to identify locations for further processing. The results of a series of experiments with monkeys performing visual search tasks have identified a population of frontal eye field (FEF) visually responsive neurons that exhibit all of the characteristics of a visual salience map. The activity of these FEF neurons is not sensitive to specific features of visual stimuli; but instead, their activity evolves over time to select the target of the search array. This selective activation reflects both the bottom-up intrinsic conspicuousness of the stimuli and the top-down knowledge and goals of the viewer. The peak response within FEF specifies the target for the overt gaze shift. However, the selective activity in FEF is not in itself a motor command because the magnitude of activation reflects the relative behavioral significance of the different stimuli in the visual scene and occurs even when no saccade is made. Identifying a visual salience map in FEF validates the theoretical concept of a salience map in many models of attention. In addition, it strengthens the emerging view that FEF is not only involved in producing overt gaze shifts, but is also important for directing covert spatial attention.

  5. Role of expected reward in frontal eye field during natural scene search

    PubMed Central

    Lawlor, Patrick N.; Ramkumar, Pavan; Kording, Konrad P.; Segraves, Mark A.

    2016-01-01

    When a saccade is expected to result in a reward, both neural activity in oculomotor areas and the saccade itself (e.g., its vigor and latency) are altered (compared with when no reward is expected). As such, it is unclear whether the correlations of neural activity with reward indicate a representation of reward beyond a movement representation; the modulated neural activity may simply represent the differences in motor output due to expected reward. Here, to distinguish between these possibilities, we trained monkeys to perform a natural scene search task while we recorded from the frontal eye field (FEF). Indeed, when reward was expected (i.e., saccades to the target), FEF neurons showed enhanced responses. Moreover, when monkeys accidentally made eye movements to the target, firing rates were lower than when they purposively moved to the target. Thus, neurons were modulated by expected reward rather than simply the presence of the target. We then fit a model that simultaneously included components related to expected reward and saccade parameters. While expected reward led to shorter latency and higher velocity saccades, these behavioral changes could not fully explain the increased FEF firing rates. Thus, FEF neurons appear to encode motivational factors such as reward expectation, above and beyond the kinematic and behavioral consequences of imminent reward. PMID:27169506

  6. Manipulation of Pre-Target Activity on the Right Frontal Eye Field Enhances Conscious Visual Perception in Humans

    PubMed Central

    Chanes, Lorena; Chica, Ana B.; Quentin, Romain; Valero-Cabré, Antoni

    2012-01-01

    The right Frontal Eye Field (FEF) is a region of the human brain, which has been consistently involved in visuo-spatial attention and access to consciousness. Nonetheless, the extent of this cortical site’s ability to influence specific aspects of visual performance remains debated. We hereby manipulated pre-target activity on the right FEF and explored its influence on the detection and categorization of low-contrast near-threshold visual stimuli. Our data show that pre-target frontal neurostimulation has the potential when used alone to induce enhancements of conscious visual detection. More interestingly, when FEF stimulation was combined with visuo-spatial cues, improvements remained present only for trials in which the cue correctly predicted the location of the subsequent target. Our data provide evidence for the causal role of the right FEF pre-target activity in the modulation of human conscious vision and reveal the dependence of such neurostimulatory effects on the state of activity set up by cue validity in the dorsal attentional orienting network. PMID:22615759

  7. Eye-Pursuit and Reafferent Head Movement Signals Carried by Pursuit Neurons in the Caudal Part of the Frontal Eye Fields during Head-Free Pursuit

    PubMed Central

    Kasahara, Satoshi; Akao, Teppei; Kurkin, Sergei; Peterson, Barry W.

    2009-01-01

    Eye and head movements are coordinated during head-free pursuit. To examine whether pursuit neurons in frontal eye fields (FEF) carry gaze-pursuit commands that drive both eye-pursuit and head-pursuit, monkeys whose heads were free to rotate about a vertical axis were trained to pursue a juice feeder with their head and a target with their eyes. Initially the feeder and target moved synchronously with the same visual angle. FEF neurons responding to this gaze-pursuit were tested for eye-pursuit of target motion while the feeder was stationary and for head-pursuit while the target was stationary. The majority of pursuit neurons exhibited modulation during head-pursuit, but their preferred directions during eye-pursuit and head-pursuit were different. Although peak modulation occurred during head movements, the onset of discharge usually was not aligned with the head movement onset. The minority of neurons whose discharge onset was so aligned discharged after the head movement onset. These results do not support the idea that the head-pursuit–related modulation reflects head-pursuit commands. Furthermore, modulation similar to that during head-pursuit was obtained by passive head rotation on stationary trunk. Our results suggest that FEF pursuit neurons issue gaze or eye movement commands during gaze-pursuit and that the head-pursuit–related modulation primarily reflects reafferent signals resulting from head movements. PMID:18483002

  8. Frontal eye fields control attentional modulation of alpha and gamma oscillations in contralateral occipitoparietal cortex.

    PubMed

    Marshall, Tom R; O'Shea, Jacinta; Jensen, Ole; Bergmann, Til O

    2015-01-28

    Covertly directing visuospatial attention produces a frequency-specific modulation of neuronal oscillations in occipital and parietal cortices: anticipatory alpha (8-12 Hz) power decreases contralateral and increases ipsilateral to attention, whereas stimulus-induced gamma (>40 Hz) power is boosted contralaterally and attenuated ipsilaterally. These modulations must be under top-down control; however, the control mechanisms are not yet fully understood. Here we investigated the causal contribution of the human frontal eye field (FEF) by combining repetitive transcranial magnetic stimulation (TMS) with subsequent magnetoencephalography. Following inhibitory theta burst stimulation to the left FEF, right FEF, or vertex, participants performed a visual discrimination task requiring covert attention to either visual hemifield. Both left and right FEF TMS caused marked attenuation of alpha modulation in the occipitoparietal cortex. Notably, alpha modulation was consistently reduced in the hemisphere contralateral to stimulation, leaving the ipsilateral hemisphere relatively unaffected. Additionally, right FEF TMS enhanced gamma modulation in left visual cortex. Behaviorally, TMS caused a relative slowing of response times to targets contralateral to stimulation during the early task period. Our results suggest that left and right FEF are causally involved in the attentional top-down control of anticipatory alpha power in the contralateral visual system, whereas a right-hemispheric dominance seems to exist for control of stimulus-induced gamma power. These findings contrast the assumption of primarily intrahemispheric connectivity between FEF and parietal cortex, emphasizing the relevance of interhemispheric interactions. The contralaterality of effects may result from a transient functional reorganization of the dorsal attention network after inhibition of either FEF. Copyright © 2015 the authors 0270-6474/15/351638-10$15.00/0.

  9. Attention Induced Gain Stabilization in Broad and Narrow-Spiking Cells in the Frontal Eye-Field of Macaque Monkeys

    PubMed Central

    Brandt, Christian; Dasilva, Miguel; Gotthardt, Sascha; Chicharro, Daniel; Panzeri, Stefano; Distler, Claudia

    2016-01-01

    Top-down attention increases coding abilities by altering firing rates and rate variability. In the frontal eye field (FEF), a key area enabling top-down attention, attention induced firing rate changes are profound, but its effect on different cell types is unknown. Moreover, FEF is the only cortical area investigated in which attention does not affect rate variability, as assessed by the Fano factor, suggesting that task engagement affects cortical state nonuniformly. We show that putative interneurons in FEF of Macaca mulatta show stronger attentional rate modulation than putative pyramidal cells. Partitioning rate variability reveals that both cell types reduce rate variability with attention, but more strongly so in narrow-spiking cells. The effects are captured by a model in which attention stabilizes neuronal excitability, thereby reducing the expansive nonlinearity that links firing rate and variance. These results show that the effect of attention on different cell classes and different coding properties are consistent across the cortical hierarchy, acting through increased and stabilized neuronal excitability. SIGNIFICANCE STATEMENT Cortical processing is critically modulated by attention. A key feature of this influence is a modulation of “cortical state,” resulting in increased neuronal excitability and resilience of the network against perturbations, lower rate variability, and an increased signal-to-noise ratio. In the frontal eye field (FEF), an area assumed to control spatial attention in human and nonhuman primates, firing rate changes with attention occur, but rate variability, quantified by the Fano factor, appears to be unaffected by attention. Using recently developed analysis tools and models to quantify attention effects on narrow- and broad-spiking cell activity, we show that attention alters cortical state strongly in the FEF, demonstrating that its effect on the neuronal network is consistent across the cortical hierarchy. PMID:27445139

  10. Serial, Covert, Shifts of Attention during Visual Search are Reflected by the Frontal Eye Fields and Correlated with Population Oscillations

    PubMed Central

    Buschman, Timothy J.; Miller, Earl K.

    2009-01-01

    Attention regulates the flood of sensory information into a manageable stream, and so understanding how attention is controlled is central to understanding cognition. Competing theories suggest visual search involves serial and/or parallel allocation of attention, but there is little direct, neural, evidence for either mechanism. Two monkeys were trained to covertly search an array for a target stimulus under visual search (endogenous) and pop-out (exogenous) conditions. Here we present neural evidence in the frontal eye fields (FEF) for serial, covert shifts of attention during search but not pop-out. Furthermore, attention shifts reflected in FEF spiking activity were correlated with 18–34 Hz oscillations in the local field potential, suggesting a ‘clocking’ signal. This provides direct neural evidence that primates can spontaneously adopt a serial search strategy and that these serial covert shifts of attention are directed by the FEF. It also suggests that neuron population oscillations may regulate the timing of cognitive processing. PMID:19679077

  11. Stimulus-response incompatibility activates cortex proximate to three eye fields

    NASA Technical Reports Server (NTRS)

    Merriam, E. P.; Colby, C. L.; Thulborn, K. R.; Luna, B.; Olson, C. R.; Sweeney, J. A.

    2001-01-01

    We used functional magnetic resonance imaging (fMRI) to investigate cortical activation during the performance of three oculomotor tasks that impose increasing levels of cognitive demand. (1) In a visually guided saccade (VGS) task, subjects made saccades to flashed targets. (2) In a compatible task, subjects made leftward and rightward saccades in response to foveal presentation of the uppercase words "LEFT" or "RIGHT." (3) In a mixed task, subjects made rightward saccades in response to the lowercase word "left" and leftward saccades in response to the lowercase word "right" on incompatible trials (60%). The remaining 40% of trials required compatible responses to uppercase words. The VGS and compatible tasks, when compared to fixation, activated the three cortical eye fields: the supplementary eye field (SEF), the frontal eye field (FEF), and the parietal eye field (PEF). The mixed task, when compared to the compatible task, activated three additional cortical regions proximate to the three eye fields: (1) rostral to the SEF in medial frontal cortex; (2) rostral to the FEF in dorsolateral prefrontal cortex (DLPFC); (3) rostral and lateral to the PEF in posterior parietal cortex. These areas may contribute to the suppression of prepotent responses and in holding novel visuomotor associations in working memory. Copyright 2001 Academic Press.

  12. A functional hierarchy within the parietofrontal network in stimulus selection and attention control.

    PubMed

    Ibos, Guilhem; Duhamel, Jean-René; Ben Hamed, Suliann

    2013-05-08

    Although we are confronted with an ever-changing environment, we do not have the capacity to analyze all incoming sensory information. Perception is selective and is guided both by salient events occurring in our visual field and by cognitive premises about what needs our attention. Although the lateral intraparietal area (LIP) and frontal eye field (FEF) are known to represent the position of visual attention, their respective contributions to its control are still unclear. Here, we report LIP and FEF neuronal activities recorded while monkeys performed a voluntary attention-orientation target-detection task. We show that both encode behaviorally significant events, but that the FEF plays a specific role in mapping abstract cue instructions onto a spatial priority map to voluntarily guide attention. On the basis of a latency analysis, we show that the coding of stimulus identity and position precedes the emergence of an explicit attentional signal within the FEF. We also describe dynamic temporal hierarchies between LIP and FEF: stimuli carrying the highest intrinsic saliency are signaled by LIP before FEF, whereas stimuli carrying the highest extrinsic saliency are signaled in FEF before LIP. This suggests that whereas the parietofrontal attentional network most probably processes visual information in a recurrent way, exogenous processing predominates in the parietal cortex and the endogenous control of attention takes place in the FEF.

  13. Simultaneous selection by object-based attention in visual and frontal cortex

    PubMed Central

    Pooresmaeili, Arezoo; Poort, Jasper; Roelfsema, Pieter R.

    2014-01-01

    Models of visual attention hold that top-down signals from frontal cortex influence information processing in visual cortex. It is unknown whether situations exist in which visual cortex actively participates in attentional selection. To investigate this question, we simultaneously recorded neuronal activity in the frontal eye fields (FEF) and primary visual cortex (V1) during a curve-tracing task in which attention shifts are object-based. We found that accurate performance was associated with similar latencies of attentional selection in both areas and that the latency in both areas increased if the task was made more difficult. The amplitude of the attentional signals in V1 saturated early during a trial, whereas these selection signals kept increasing for a longer time in FEF, until the moment of an eye movement, as if FEF integrated attentional signals present in early visual cortex. In erroneous trials, we observed an interareal latency difference because FEF selected the wrong curve before V1 and imposed its erroneous decision onto visual cortex. The neuronal activity in visual and frontal cortices was correlated across trials, and this trial-to-trial coupling was strongest for the attended curve. These results imply that selective attention relies on reciprocal interactions within a large network of areas that includes V1 and FEF. PMID:24711379

  14. Direct evidence for attention-dependent influences of the frontal eye-fields on feature-responsive visual cortex.

    PubMed

    Heinen, Klaartje; Feredoes, Eva; Weiskopf, Nikolaus; Ruff, Christian C; Driver, Jon

    2014-11-01

    Voluntary selective attention can prioritize different features in a visual scene. The frontal eye-fields (FEF) are one potential source of such feature-specific top-down signals, but causal evidence for influences on visual cortex (as was shown for "spatial" attention) has remained elusive. Here, we show that transcranial magnetic stimulation (TMS) applied to right FEF increased the blood oxygen level-dependent (BOLD) signals in visual areas processing "target feature" but not in "distracter feature"-processing regions. TMS-induced BOLD signals increase in motion-responsive visual cortex (MT+) when motion was attended in a display with moving dots superimposed on face stimuli, but in face-responsive fusiform area (FFA) when faces were attended to. These TMS effects on BOLD signal in both regions were negatively related to performance (on the motion task), supporting the behavioral relevance of this pathway. Our findings provide new causal evidence for the human FEF in the control of nonspatial "feature"-based attention, mediated by dynamic influences on feature-specific visual cortex that vary with the currently attended property. © The Author 2013. Published by Oxford University Press.

  15. Copula Regression Analysis of Simultaneously Recorded Frontal Eye Field and Inferotemporal Spiking Activity during Object-Based Working Memory

    PubMed Central

    Hu, Meng; Clark, Kelsey L.; Gong, Xiajing; Noudoost, Behrad; Li, Mingyao; Moore, Tirin

    2015-01-01

    Inferotemporal (IT) neurons are known to exhibit persistent, stimulus-selective activity during the delay period of object-based working memory tasks. Frontal eye field (FEF) neurons show robust, spatially selective delay period activity during memory-guided saccade tasks. We present a copula regression paradigm to examine neural interaction of these two types of signals between areas IT and FEF of the monkey during a working memory task. This paradigm is based on copula models that can account for both marginal distribution over spiking activity of individual neurons within each area and joint distribution over ensemble activity of neurons between areas. Considering the popular GLMs as marginal models, we developed a general and flexible likelihood framework that uses the copula to integrate separate GLMs into a joint regression analysis. Such joint analysis essentially leads to a multivariate analog of the marginal GLM theory and hence efficient model estimation. In addition, we show that Granger causality between spike trains can be readily assessed via the likelihood ratio statistic. The performance of this method is validated by extensive simulations, and compared favorably to the widely used GLMs. When applied to spiking activity of simultaneously recorded FEF and IT neurons during working memory task, we observed significant Granger causality influence from FEF to IT, but not in the opposite direction, suggesting the role of the FEF in the selection and retention of visual information during working memory. The copula model has the potential to provide unique neurophysiological insights about network properties of the brain. PMID:26063909

  16. Visual–Motor Transformations Within Frontal Eye Fields During Head-Unrestrained Gaze Shifts in the Monkey

    PubMed Central

    Sajad, Amirsaman; Sadeh, Morteza; Keith, Gerald P.; Yan, Xiaogang; Wang, Hongying; Crawford, John Douglas

    2015-01-01

    A fundamental question in sensorimotor control concerns the transformation of spatial signals from the retina into eye and head motor commands required for accurate gaze shifts. Here, we investigated these transformations by identifying the spatial codes embedded in visually evoked and movement-related responses in the frontal eye fields (FEFs) during head-unrestrained gaze shifts. Monkeys made delayed gaze shifts to the remembered location of briefly presented visual stimuli, with delay serving to dissociate visual and movement responses. A statistical analysis of nonparametric model fits to response field data from 57 neurons (38 with visual and 49 with movement activities) eliminated most effector-specific, head-fixed, and space-fixed models, but confirmed the dominance of eye-centered codes observed in head-restrained studies. More importantly, the visual response encoded target location, whereas the movement response mainly encoded the final position of the imminent gaze shift (including gaze errors). This spatiotemporal distinction between target and gaze coding was present not only at the population level, but even at the single-cell level. We propose that an imperfect visual–motor transformation occurs during the brief memory interval between perception and action, and further transformations from the FEF's eye-centered gaze motor code to effector-specific codes in motor frames occur downstream in the subcortical areas. PMID:25491118

  17. Neuronal and behavioural modulations by pathway-selective optogenetic stimulation of the primate oculomotor system

    PubMed Central

    Inoue, Ken-ichi; Takada, Masahiko; Matsumoto, Masayuki

    2015-01-01

    Optogenetics enables temporally and spatially precise control of neuronal activity in vivo. One of the key advantages of optogenetics is that it can be used to control the activity of targeted neural pathways that connect specific brain regions. While such pathway-selective optogenetic control is a popular tool in rodents, attempts at modulating behaviour using pathway-selective optogenetics have not yet been successful in primates. Here we develop a methodology for pathway-selective optogenetics in macaque monkeys, focusing on the pathway from the frontal eye field (FEF) to the superior colliculus (SC), part of the complex oculomotor network. We find that the optogenetic stimulation of FEF projections to the SC modulates SC neuron activity and is sufficient to evoke saccadic eye movements towards the response field corresponding to the stimulation site. Thus, our results demonstrate the feasibility of using pathway-selective optogenetics to elucidate neural network function in primates. PMID:26387804

  18. Neuronal and behavioural modulations by pathway-selective optogenetic stimulation of the primate oculomotor system.

    PubMed

    Inoue, Ken-ichi; Takada, Masahiko; Matsumoto, Masayuki

    2015-09-21

    Optogenetics enables temporally and spatially precise control of neuronal activity in vivo. One of the key advantages of optogenetics is that it can be used to control the activity of targeted neural pathways that connect specific brain regions. While such pathway-selective optogenetic control is a popular tool in rodents, attempts at modulating behaviour using pathway-selective optogenetics have not yet been successful in primates. Here we develop a methodology for pathway-selective optogenetics in macaque monkeys, focusing on the pathway from the frontal eye field (FEF) to the superior colliculus (SC), part of the complex oculomotor network. We find that the optogenetic stimulation of FEF projections to the SC modulates SC neuron activity and is sufficient to evoke saccadic eye movements towards the response field corresponding to the stimulation site. Thus, our results demonstrate the feasibility of using pathway-selective optogenetics to elucidate neural network function in primates.

  19. Impaired Activation of Visual Attention Network for Motion Salience Is Accompanied by Reduced Functional Connectivity between Frontal Eye Fields and Visual Cortex in Strabismic Amblyopia

    PubMed Central

    Wang, Hao; Crewther, Sheila G.; Liang, Minglong; Laycock, Robin; Yu, Tao; Alexander, Bonnie; Crewther, David P.; Wang, Jian; Yin, Zhengqin

    2017-01-01

    Strabismic amblyopia is now acknowledged to be more than a simple loss of acuity and to involve alterations in visually driven attention, though whether this applies to both stimulus-driven and goal-directed attention has not been explored. Hence we investigated monocular threshold performance during a motion salience-driven attention task involving detection of a coherent dot motion target in one of four quadrants in adult controls and those with strabismic amblyopia. Psychophysical motion thresholds were impaired for the strabismic amblyopic eye, requiring longer inspection time and consequently slower target speed for detection compared to the fellow eye or control eyes. We compared fMRI activation and functional connectivity between four ROIs of the occipital-parieto-frontal visual attention network [primary visual cortex (V1), motion sensitive area V5, intraparietal sulcus (IPS) and frontal eye fields (FEF)], during a suprathreshold version of the motion-driven attention task, and also a simple goal-directed task, requiring voluntary saccades to targets randomly appearing along a horizontal line. Activation was compared when viewed monocularly by controls and the amblyopic and its fellow eye in strabismics. BOLD activation was weaker in IPS, FEF and V5 for both tasks when viewing through the amblyopic eye compared to viewing through the fellow eye or control participants' non-dominant eye. No difference in V1 activation was seen between the amblyopic and fellow eye, nor between the two eyes of control participants during the motion salience task, though V1 activation was significantly less through the amblyopic eye than through the fellow eye and control group non-dominant eye viewing during the voluntary saccade task. Functional correlations of ROIs within the attention network were impaired through the amblyopic eye during the motion salience task, whereas this was not the case during the voluntary saccade task. Specifically, FEF showed reduced functional connectivity with visual cortical nodes during the motion salience task through the amblyopic eye, despite suprathreshold detection performance. This suggests that the reduced ability of the amblyopic eye to activate the frontal components of the attention networks may help explain the aberrant control of visual attention and eye movements in amblyopes. PMID:28484381

  20. Visual-Motor Transformations Within Frontal Eye Fields During Head-Unrestrained Gaze Shifts in the Monkey.

    PubMed

    Sajad, Amirsaman; Sadeh, Morteza; Keith, Gerald P; Yan, Xiaogang; Wang, Hongying; Crawford, John Douglas

    2015-10-01

    A fundamental question in sensorimotor control concerns the transformation of spatial signals from the retina into eye and head motor commands required for accurate gaze shifts. Here, we investigated these transformations by identifying the spatial codes embedded in visually evoked and movement-related responses in the frontal eye fields (FEFs) during head-unrestrained gaze shifts. Monkeys made delayed gaze shifts to the remembered location of briefly presented visual stimuli, with delay serving to dissociate visual and movement responses. A statistical analysis of nonparametric model fits to response field data from 57 neurons (38 with visual and 49 with movement activities) eliminated most effector-specific, head-fixed, and space-fixed models, but confirmed the dominance of eye-centered codes observed in head-restrained studies. More importantly, the visual response encoded target location, whereas the movement response mainly encoded the final position of the imminent gaze shift (including gaze errors). This spatiotemporal distinction between target and gaze coding was present not only at the population level, but even at the single-cell level. We propose that an imperfect visual-motor transformation occurs during the brief memory interval between perception and action, and further transformations from the FEF's eye-centered gaze motor code to effector-specific codes in motor frames occur downstream in the subcortical areas. © The Author 2014. Published by Oxford University Press.

  1. Internally-generated error signals in monkey frontal eye field during an inferred motion task

    PubMed Central

    Ferrera, Vincent P.; Barborica, Andrei

    2010-01-01

    An internal model for predictive saccades in frontal cortex was investigated by recording neurons in monkey frontal eye field during an inferred motion task. Monkeys were trained to make saccades to the extrapolated position of a small moving target that was rendered temporarily invisible and whose trajectory was altered. On roughly two-thirds of the trials, monkeys made multiple saccades while the target was invisible. Primary saccades were correlated with extrapolated target position. Secondary saccades significantly reduced residual errors resulting from imperfect accuracy of the first saccade. These observations suggest that the second saccade was corrective. As there was no visual feedback, corrective saccades could only be driven by an internally generated error signal. Neuronal activity in the frontal eye field was directionally tuned prior to both primary and secondary saccades. Separate subpopulations of cells encoded either saccade direction or direction error prior to the second saccade. These results suggest that FEF neurons encode the error after the first saccade, as well as the direction of the second saccade. Hence, FEF appears to contribute to detecting and correcting movement errors based on internally generated signals. PMID:20810882

  2. Functional connectivity between prefrontal and parietal cortex drives visuo-spatial attention shifts.

    PubMed

    Heinen, Klaartje; Feredoes, Eva; Ruff, Christian C; Driver, Jon

    2017-05-01

    It is well established that the frontal eye-fields (FEF) in the dorsal attention network (DAN) guide top-down selective attention. In addition, converging evidence implies a causal role for the FEF in attention shifting, which is also known to recruit the ventral attention network (VAN) and fronto-striatal regions. To investigate the causal influence of the FEF as (part of) a central hub between these networks, we applied thetaburst transcranial magnetic stimulation (TBS) off-line, combined with functional magnetic resonance (fMRI) during a cued visuo-spatial attention shifting paradigm. We found that TBS over the right FEF impaired performance on a visual discrimination task in both hemifields following attention shifts, while only left hemifield performance was affected when participants were cued to maintain the focus of attention. These effects recovered ca. 20min post stimulation. Furthermore, particularly following attention shifts, TBS suppressed the neural signal in bilateral FEF, right inferior and superior parietal lobule (IPL/SPL) and bilateral supramarginal gyri (SMG). Immediately post stimulation, functional connectivity was impaired between right FEF and right SMG as well as right putamen. Importantly, the extent of decreased connectivity between right FEF and right SMG correlated with behavioural impairment following attention shifts. The main finding of this study demonstrates that influences from right FEF on SMG in the ventral attention network causally underly attention shifts, presumably by enabling disengagement from the current focus of attention. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  3. Motor output evoked by subsaccadic stimulation of primate frontal eye fields.

    PubMed

    Corneil, Brian D; Elsley, James K; Nagy, Benjamin; Cushing, Sharon L

    2010-03-30

    In addition to its role in shifting the line of sight, the oculomotor system is also involved in the covert orienting of visuospatial attention. Causal evidence supporting this premotor theory of attention, or oculomotor readiness hypothesis, comes from the effect of subsaccadic threshold stimulation of the oculomotor system on behavior and neural activity in the absence of evoked saccades, which parallels the effects of covert attention. Here, by recording neck-muscle activity from monkeys and systematically titrating the level of stimulation current delivered to the frontal eye fields (FEF), we show that such subsaccadic stimulation is not divorced from immediate motor output but instead evokes neck-muscle responses at latencies that approach the minimal conduction time to the motor periphery. On average, neck-muscle thresholds were approximately 25% lower than saccade thresholds, and this difference is larger for FEF sites associated with progressively larger saccades. Importantly, we commonly observed lower neck-muscle thresholds even at sites evoking saccades

  4. Neural chronometry and coherency across speed-accuracy demands reveal lack of homomorphism between computational and neural mechanisms of evidence accumulation.

    PubMed

    Heitz, Richard P; Schall, Jeffrey D

    2013-10-19

    The stochastic accumulation framework provides a mechanistic, quantitative account of perceptual decision-making and how task performance changes with experimental manipulations. Importantly, it provides an elegant account of the speed-accuracy trade-off (SAT), which has long been the litmus test for decision models, and also mimics the activity of single neurons in several key respects. Recently, we developed a paradigm whereby macaque monkeys trade speed for accuracy on cue during visual search task. Single-unit activity in frontal eye field (FEF) was not homomorphic with the architecture of models, demonstrating that stochastic accumulators are an incomplete description of neural activity under SAT. This paper summarizes and extends this work, further demonstrating that the SAT leads to extensive, widespread changes in brain activity never before predicted. We will begin by reviewing our recently published work that establishes how spiking activity in FEF accomplishes SAT. Next, we provide two important extensions of this work. First, we report a new chronometric analysis suggesting that increases in perceptual gain with speed stress are evident in FEF synaptic input, implicating afferent sensory-processing sources. Second, we report a new analysis demonstrating selective influence of SAT on frequency coupling between FEF neurons and local field potentials. None of these observations correspond to the mechanics of current accumulator models.

  5. Projections of Somatosensory Cortex and Frontal Eye Fields onto Incertotectal Neurons in the Cat

    PubMed Central

    Perkins, Eddie; Warren, Susan; Lin, Rick C.-S.; May, Paul J.

    2014-01-01

    The goal of this study was to determine whether the input-output characteristics of the zona incerta (ZI) are appropriate for it to serve as a conduit for cortical control over saccade-related activity in the superior colliculus. The study utilized the neuronal tracers wheat germ agglutinin-horseradish peroxidase (WGA-HRP) and biotinylated dextran amine (BDA) in the cat. Injections of WGA-HRP into primary somatosensory cortex (SI) revealed sparse, widespread nontopographic projections throughout ZI. In addition, region-specific areas of more intense termination were present in ventral ZI, although strict topography was not observed. In comparison, the frontal eye fields (FEF) also projected sparsely throughout ZI, but terminated more heavily, medially, along the border between the two sublaminae. Furthermore, retrogradely labeled incertocortical neurons were observed in both experiments. The relationship of these two cortical projections to incertotectal cells was also directly examined by retrogradely labeling incertotectal cells with WGA-HRP in animals that had also received cortical BDA injections. Labeled axonal arbors from both SI and FEF had thin, sparsely branched axons with numerous en passant boutons. They formed numerous close associations with the somata and dendrites of WGA-HRP-labeled incertotectal cells. In summary, these results indicate that both sensory and motor cortical inputs to ZI display similar morphologies and distributions. In addition, both display close associations with incertotectal cells, suggesting direct synaptic contact. From these data, we conclude that inputs from somatosensory and FEF cortex both play a role in controlling gaze-related activity in the superior colliculus by way of the inhibitory incertotectal projection. PMID:17083121

  6. Saccade Generation by the Frontal Eye Fields in Rhesus Monkeys Is Separable from Visual Detection and Bottom-Up Attention Shift

    PubMed Central

    Lee, Kyoung-Min; Ahn, Kyung-Ha; Keller, Edward L.

    2012-01-01

    The frontal eye fields (FEF), originally identified as an oculomotor cortex, have also been implicated in perceptual functions, such as constructing a visual saliency map and shifting visual attention. Further dissecting the area’s role in the transformation from visual input to oculomotor command has been difficult because of spatial confounding between stimuli and responses and consequently between intermediate cognitive processes, such as attention shift and saccade preparation. Here we developed two tasks in which the visual stimulus and the saccade response were dissociated in space (the extended memory-guided saccade task), and bottom-up attention shift and saccade target selection were independent (the four-alternative delayed saccade task). Reversible inactivation of the FEF in rhesus monkeys disrupted, as expected, contralateral memory-guided saccades, but visual detection was demonstrated to be intact at the same field. Moreover, saccade behavior was impaired when a bottom-up shift of attention was not a prerequisite for saccade target selection, indicating that the inactivation effect was independent of the previously reported dysfunctions in bottom-up attention control. These findings underscore the motor aspect of the area’s functions, especially in situations where saccades are generated by internal cognitive processes, including visual short-term memory and long-term associative memory. PMID:22761923

  7. Saccade generation by the frontal eye fields in rhesus monkeys is separable from visual detection and bottom-up attention shift.

    PubMed

    Lee, Kyoung-Min; Ahn, Kyung-Ha; Keller, Edward L

    2012-01-01

    The frontal eye fields (FEF), originally identified as an oculomotor cortex, have also been implicated in perceptual functions, such as constructing a visual saliency map and shifting visual attention. Further dissecting the area's role in the transformation from visual input to oculomotor command has been difficult because of spatial confounding between stimuli and responses and consequently between intermediate cognitive processes, such as attention shift and saccade preparation. Here we developed two tasks in which the visual stimulus and the saccade response were dissociated in space (the extended memory-guided saccade task), and bottom-up attention shift and saccade target selection were independent (the four-alternative delayed saccade task). Reversible inactivation of the FEF in rhesus monkeys disrupted, as expected, contralateral memory-guided saccades, but visual detection was demonstrated to be intact at the same field. Moreover, saccade behavior was impaired when a bottom-up shift of attention was not a prerequisite for saccade target selection, indicating that the inactivation effect was independent of the previously reported dysfunctions in bottom-up attention control. These findings underscore the motor aspect of the area's functions, especially in situations where saccades are generated by internal cognitive processes, including visual short-term memory and long-term associative memory.

  8. Downregulated Kynurenine 3-Monooxygenase Gene Expression and Enzyme Activity in Schizophrenia and Genetic Association With Schizophrenia Endophenotypes

    PubMed Central

    Wonodi, Ikwunga; Stine, O. Colin; Sathyasaikumar, Korrapati V.; Roberts, Rosalinda C.; Mitchell, Braxton D.; Hong, L. Elliot; Kajii, Yasushi; Thaker, Gunvant K.; Schwarcz, Robert

    2013-01-01

    Context Kynurenic acid, a metabolite of the kynurenine pathway of tryptophan degradation, is an antagonist at N-methyl-d-aspartate and α7 nicotinic acetylcholine receptors and modulates glutamate, dopamine, and acetylcholine signaling. Cortical kynurenic acid concentrations are elevated in the brain and cerebrospinal fluid of schizophrenia patients. The proximal cause may be an impairment of kynurenine 3-monooxygenase (KMO), a rate-limiting enzyme at the branching point of the kynurenine pathway. Objectives To examine KMO messenger RNA expression and KMO enzyme activity in postmortem tissue from the frontal eye field (FEF; Brodmann area 6) obtained from schizophrenia individuals compared with healthy control individuals and to explore the relationship between KMO single-nucleotide polymorphisms and schizophrenia oculomotor endophenotypes. Design Case-control postmortem and clinical study. Setting Maryland Brain Collection, outpatient clinics. Participants Postmortem specimens from schizophrenia patients (n=32) and control donors (n=32) and a clinical sample of schizophrenia patients (n=248) and healthy controls (n=228). Main Outcome Measures Comparison of quantitative KMO messenger RNA expression and KMO enzyme activity in postmortem FEF tissue between schizophrenia patients and controls and association of KMO single-nucleotide polymorphisms with messenger RNA expression in postmortem FEF and schizophrenia and oculomotor endophenotypes (ie, smooth pursuit eye movements and oculomotor delayed response). Results In postmortem tissue, we found a significant and correlated reduction in KMO gene expression and KMO enzyme activity in the FEF in schizophrenia patients. In the clinical sample, KMO rs2275163 was not associated with a diagnosis of schizophrenia but showed modest effects on predictive pursuit and visuospatial working memory endophenotypes. Conclusion Our results provide converging lines of evidence implicating reduced KMO activity in the etiopathophysiology of schizophrenia and related neurocognitive deficits. PMID:21727251

  9. Downregulated kynurenine 3-monooxygenase gene expression and enzyme activity in schizophrenia and genetic association with schizophrenia endophenotypes.

    PubMed

    Wonodi, Ikwunga; Stine, O Colin; Sathyasaikumar, Korrapati V; Roberts, Rosalinda C; Mitchell, Braxton D; Hong, L Elliot; Kajii, Yasushi; Thaker, Gunvant K; Schwarcz, Robert

    2011-07-01

    Kynurenic acid, a metabolite of the kynurenine pathway of tryptophan degradation, is an antagonist at N-methyl-d-aspartate and α7 nicotinic acetylcholine receptors and modulates glutamate, dopamine, and acetylcholine signaling. Cortical kynurenic acid concentrations are elevated in the brain and cerebrospinal fluid of schizophrenia patients. The proximal cause may be an impairment of kynurenine 3-monooxygenase (KMO), a rate-limiting enzyme at the branching point of the kynurenine pathway. To examine KMO messenger RNA expression and KMO enzyme activity in postmortem tissue from the frontal eye field (FEF; Brodmann area 6) obtained from schizophrenia individuals compared with healthy control individuals and to explore the relationship between KMO single-nucleotide polymorphisms and schizophrenia oculomotor endophenotypes. Case-control postmortem and clinical study. Maryland Brain Collection, outpatient clinics. Postmortem specimens from schizophrenia patients (n = 32) and control donors (n = 32) and a clinical sample of schizophrenia patients (n = 248) and healthy controls (n = 228). Comparison of quantitative KMO messenger RNA expression and KMO enzyme activity in postmortem FEF tissue between schizophrenia patients and controls and association of KMO single-nucleotide polymorphisms with messenger RNA expression in postmortem FEF and schizophrenia and oculomotor endophenotypes (ie, smooth pursuit eye movements and oculomotor delayed response). In postmortem tissue, we found a significant and correlated reduction in KMO gene expression and KMO enzyme activity in the FEF in schizophrenia patients. In the clinical sample, KMO rs2275163 was not associated with a diagnosis of schizophrenia but showed modest effects on predictive pursuit and visuospatial working memory endophenotypes. Our results provide converging lines of evidence implicating reduced KMO activity in the etiopathophysiology of schizophrenia and related neurocognitive deficits.

  10. Ghosts in the Machine II: Neural Correlates of Memory Interference from the Previous Trial.

    PubMed

    Papadimitriou, Charalampos; White, Robert L; Snyder, Lawrence H

    2017-04-01

    Previous memoranda interfere with working memory. For example, spatial memories are biased toward locations memorized on the previous trial. We predicted, based on attractor network models of memory, that activity in the frontal eye fields (FEFs) encoding a previous target location can persist into the subsequent trial and that this ghost will then bias the readout of the current target. Contrary to this prediction, we find that FEF memory representations appear biased away from (not toward) the previous target location. The behavioral and neural data can be reconciled by a model in which receptive fields of memory neurons converge toward remembered locations, much as receptive fields converge toward attended locations. Convergence increases the resources available to encode the relevant memoranda and decreases overall error in the network, but the residual convergence from the previous trial can give rise to an attractive behavioral bias on the next trial. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  11. Temporal dynamics of retinal and extraretinal signals in the FEFsem during smooth pursuit eye movements

    PubMed Central

    Bakst, Leah; Fleuriet, Jérome

    2017-01-01

    Neurons in the smooth eye movement subregion of the frontal eye field (FEFsem) are known to play an important role in voluntary smooth pursuit eye movements. Underlying this function are projections to parietal and prefrontal visual association areas and subcortical structures, all known to play vital but differing roles in the execution of smooth pursuit. Additionally, the FEFsem has been shown to carry a diverse array of signals (e.g., eye velocity, acceleration, gain control). We hypothesized that distinct subpopulations of FEFsem neurons subserve these diverse functions and projections, and that the relative weights of retinal and extraretinal signals could form the basis for categorization of units. To investigate this, we used a step-ramp tracking task with a target blink to determine the relative contributions of retinal and extraretinal signals in individual FEFsem neurons throughout pursuit. We found that the contributions of retinal and extraretinal signals to neuronal activity and behavior change throughout the time course of pursuit. A clustering algorithm revealed three distinct neuronal subpopulations: cluster 1 was defined by a higher sensitivity to eye velocity, acceleration, and retinal image motion; cluster 2 had greater activity during blinks; and cluster 3 had significantly greater eye position sensitivity. We also performed a comparison with a sample of medial superior temporal neurons to assess similarities and differences between the two areas. Our results indicate the utility of simple tests such as the target blink for parsing the complex and multifaceted roles of cortical areas in behavior. NEW & NOTEWORTHY The frontal eye field (FEF) is known to play a critical role in volitional smooth pursuit, carrying a variety of signals that are distributed throughout the brain. This study used a novel application of a target blink task during step ramp tracking to determine, in combination with a clustering algorithm, the relative contributions of retinal and extraretinal signals to FEF activity and the extent to which these contributions could form the basis for a categorization of neurons. PMID:28202571

  12. fMRI evidence of improved visual function in patients with progressive retinitis pigmentosa by eye-movement training.

    PubMed

    Yoshida, Masako; Origuchi, Maki; Urayama, Shin-Ichi; Takatsuki, Akira; Kan, Shigeyuki; Aso, Toshihiko; Shiose, Takayuki; Sawamoto, Nobukatsu; Miyauchi, Satoru; Fukuyama, Hidenao; Seiyama, Akitoshi

    2014-01-01

    To evaluate changes in the visual processing of patients with progressive retinitis pigmentosa (RP) who acquired improved reading capability by eye-movement training (EMT), we performed functional magnetic resonance imaging (fMRI) before and after EMT. Six patients with bilateral concentric contraction caused by pigmentary degeneration of the retina and 6 normal volunteers were recruited. Patients were given EMT for 5 min every day for 8-10 months. fMRI data were acquired on a 3.0-Tesla scanner while subjects were performing reading tasks. In separate experiments (before fMRI scanning), visual performances for readings were measured by the number of letters read correctly in 5 min. Before EMT, activation areas of the primary visual cortex of patients were 48.8% of those of the controls. The number of letters read correctly in 5 min was 36.6% of those by the normal volunteers. After EMT, the activation areas of patients were not changed or slightly decreased; however, reading performance increased in 5 of 6 patients, which was 46.6% of that of the normal volunteers (p< 0.05). After EMT, increased activity was observed in the frontal eye fields (FEFs) of all patients; however, increases in the activity of the parietal eye fields (PEFs) were observed only in patients who showed greater improvement in reading capability. The improvement in reading ability of the patients after EMT is regarded as an effect of the increased activity of FEF and PEF, which play important roles in attention and working memory as well as the regulation of eye movements.

  13. fMRI evidence of improved visual function in patients with progressive retinitis pigmentosa by eye-movement training

    PubMed Central

    Yoshida, Masako; Origuchi, Maki; Urayama, Shin-ichi; Takatsuki, Akira; Kan, Shigeyuki; Aso, Toshihiko; Shiose, Takayuki; Sawamoto, Nobukatsu; Miyauchi, Satoru; Fukuyama, Hidenao; Seiyama, Akitoshi

    2014-01-01

    To evaluate changes in the visual processing of patients with progressive retinitis pigmentosa (RP) who acquired improved reading capability by eye-movement training (EMT), we performed functional magnetic resonance imaging (fMRI) before and after EMT. Six patients with bilateral concentric contraction caused by pigmentary degeneration of the retina and 6 normal volunteers were recruited. Patients were given EMT for 5 min every day for 8–10 months. fMRI data were acquired on a 3.0-Tesla scanner while subjects were performing reading tasks. In separate experiments (before fMRI scanning), visual performances for readings were measured by the number of letters read correctly in 5 min. Before EMT, activation areas of the primary visual cortex of patients were 48.8% of those of the controls. The number of letters read correctly in 5 min was 36.6% of those by the normal volunteers. After EMT, the activation areas of patients were not changed or slightly decreased; however, reading performance increased in 5 of 6 patients, which was 46.6% of that of the normal volunteers (p< 0.05). After EMT, increased activity was observed in the frontal eye fields (FEFs) of all patients; however, increases in the activity of the parietal eye fields (PEFs) were observed only in patients who showed greater improvement in reading capability. The improvement in reading ability of the patients after EMT is regarded as an effect of the increased activity of FEF and PEF, which play important roles in attention and working memory as well as the regulation of eye movements. PMID:25068106

  14. Site-dependent effects of tDCS uncover dissociations in the communication network underlying the processing of visual search.

    PubMed

    Ball, Keira; Lane, Alison R; Smith, Daniel T; Ellison, Amanda

    2013-11-01

    The right posterior parietal cortex (rPPC) and the right frontal eye field (rFEF) form part of a network of brain areas involved in orienting spatial attention. Previous studies using transcranial magnetic stimulation (TMS) have demonstrated that both areas are critically involved in the processing of conjunction visual search tasks, since stimulation of these sites disrupts performance. This study investigated the effects of long term neuronal modulation to rPPC and rFEF using transcranial direct current stimulation (tDCS) with the aim of uncovering sharing of these resources in the processing of conjunction visual search tasks. Participants completed four blocks of conjunction search trials over the course of 45 min. Following the first block they received 15 min of either cathodal or anodal stimulation to rPPC or rFEF, or sham stimulation. A significant interaction between block and stimulation condition was found, indicating that tDCS caused different effects according to the site (rPPC or rFEF) and type of stimulation (cathodal, anodal, or sham). Practice resulted in a significant reduction in reaction time across the four blocks in all conditions except when cathodal tDCS was applied to rPPC. The effects of cathodal tDCS over rPPC are subtler than those seen with TMS, and no effect of tDCS was evident at rFEF. This suggests that rFEF has a more transient role than rPPC in the processing of conjunction visual search and is robust to longer-term methods of neuro-disruption. Our results may be explained within the framework of functional connectivity between these, and other, areas. Copyright © 2013 Elsevier Inc. All rights reserved.

  15. Frontal Non-Invasive Neurostimulation Modulates Antisaccade Preparation in Non-Human Primates

    PubMed Central

    Valero-Cabre, Antoni; Wattiez, Nicolas; Monfort, Morgane; François, Chantal; Rivaud-Péchoux, Sophie; Gaymard, Bertrand; Pouget, Pierre

    2012-01-01

    A combination of oculometric measurements, invasive electrophysiological recordings and microstimulation have proven instrumental to study the role of the Frontal Eye Field (FEF) in saccadic activity. We hereby gauged the ability of a non-invasive neurostimulation technology, Transcranial Magnetic Stimulation (TMS), to causally interfere with frontal activity in two macaque rhesus monkeys trained to perform a saccadic antisaccade task. We show that online single pulse TMS significantly modulated antisaccade latencies. Such effects proved dependent on TMS site (effects on FEF but not on an actively stimulated control site), TMS modality (present under active but not sham TMS on the FEF area), TMS intensity (intensities of at least 40% of the TMS machine maximal output required), TMS timing (more robust for pulses delivered at 150 ms than at 100 post target onset) and visual hemifield (relative latency decreases mainly for ipsilateral AS). Our results demonstrate the feasibility of using TMS to causally modulate antisaccade-associated computations in the non-human primate brain and support the use of this approach in monkeys to study brain function and its non-invasive neuromodulation for exploratory and therapeutic purposes. PMID:22701691

  16. Task-related modulation of effective connectivity during perceptual decision making: dissociation between dorsal and ventral prefrontal cortex.

    PubMed

    Akaishi, Rei; Ueda, Naoko; Sakai, Katsuyuki

    2013-01-01

    The dorsal and ventral parts of the lateral prefrontal cortex have been thought to play distinct roles in decision making. Although its dorsal part such as the frontal eye field (FEF) is shown to play roles in accumulation of sensory information during perceptual decision making, the role of the ventral prefrontal cortex (PFv) is not well-documented. Previous studies have suggested that the PFv is involved in selective attention to the task-relevant information and is associated with accuracy of the behavioral performance. It is unknown, however, whether the accumulation and selection processes are anatomically dissociated between the FEF and PFv. Here we show that, by using concurrent TMS and EEG recording, the short-latency (20-40 ms) TMS-evoked potentials after stimulation of the FEF change as a function of the time to behavioral response, whereas those after stimulation of the PFv change depending on whether the response is correct or not. The potentials after stimulation of either region did not show significant interaction between time to response and performance accuracy, suggesting dissociation between the processes subserved by the FEF and PFv networks. The results are consistent with the idea that the network involving the FEF plays a role in information accumulation, whereas the network involving the PFv plays a role in selecting task relevant information. In addition, stimulation of the FEF and PFv induced activation in common regions in the dorsolateral and medial frontal cortices, suggesting convergence of information processed in the two regions. Taken together, the results suggest dissociation between the FEF and PFv networks for their computational roles in perceptual decision making. The study also highlights the advantage of TMS-EEG technique in investigating the computational processes subserved by the neural network in the human brain with a high temporal resolution.

  17. Frontal Preparatory Neural Oscillations Associated with Cognitive Control: A Developmental Study Comparing Young Adults and Adolescents

    PubMed Central

    Hwang, Kai; Ghuman, Avniel S.; Manoach, Dara S.; Jones, Stephanie R.; Luna, Beatriz

    2016-01-01

    Functional magnetic resonance imaging (fMRI) studies suggest that age-related changes in the frontal cortex may underlie developmental improvements in cognitive control. In the present study we used magnetoencephalography (MEG) to identify frontal oscillatory neurodynamics that support age-related improvements in cognitive control during adolescence. We characterized the differences in neural oscillations in adolescents and adults during the preparation to suppress a prepotent saccade (antisaccade trials – AS) compared to preparing to generate a more automatic saccade (prosaccade trials – PS). We found that for adults, AS were associated with increased beta-band (16–38 Hz) power in the dorsal lateral prefrontal cortex (DLPFC), enhanced alpha- to low beta-band (10–18 Hz) power in the frontal eye field (FEF) that predicted performance, and increased cross-frequency alpha-beta (10–26 Hz) amplitude coupling between the DLPFC and the FEF. Developmental comparisons between adults and adolescents revealed similar engagement of DLPFC beta-band power but weaker FEF alpha-band power, and lower cross-frequency coupling between the DLPFC and the FEF in adolescents. These results suggest that lateral prefrontal neural activity associated with cognitive control is adult-like by adolescence; the development of cognitive control from adolescence to adulthood is instead associated with increases in prefrontal connectivity and strengthening of inhibition signaling for suppressing task-incompatible processes. PMID:27173759

  18. Human dorsolateral prefrontal cortex is involved in visual search for conjunctions but not features: a theta TMS study.

    PubMed

    Kalla, Roger; Muggleton, Neil G; Cowey, Alan; Walsh, Vincent

    2009-10-01

    Functional neuroimaging studies have shown that the detection of a target defined by more than one feature (for example, a conjunction of colour and orientation) amongst distractors is associated with the activation of a network of brain areas. Dorsolateral prefrontal cortex (DLPFC), along with areas such as the frontal eye fields (FEF) and posterior parietal cortex (PPC), is a component of this network. While transcranial magnetic stimulation (TMS) had shown that both FEF and PPC are necessary for, and not just correlated with, successful conjunction search, this is not the case for DLPFC. To test the hypothesis that this area is also necessary for efficient conjunction search, TMS was applied over DLPFC and the effects on conjunction and feature (in this case colour) search performance compared with those when TMS was delivered over area MT/V5 and a vertex control stimulation condition. DLPFC TMS impaired performance on the conjunction search task but was without effect on feature search, similar to findings when TMS is delivered over PPC or FEF. Vertex TMS had no effects whereas MT/V5 TMS significantly improved performance with a time course that may indicate that this was due to modulation of V4 activity. These findings illustrate that, like FEF and PPC, DLPFC is necessary for fully effective conjunction visual search performance.

  19. Cognitive processes involved in smooth pursuit eye movements: behavioral evidence, neural substrate and clinical correlation

    PubMed Central

    Fukushima, Kikuro; Fukushima, Junko; Warabi, Tateo; Barnes, Graham R.

    2013-01-01

    Smooth-pursuit eye movements allow primates to track moving objects. Efficient pursuit requires appropriate target selection and predictive compensation for inherent processing delays. Prediction depends on expectation of future object motion, storage of motion information and use of extra-retinal mechanisms in addition to visual feedback. We present behavioral evidence of how cognitive processes are involved in predictive pursuit in normal humans and then describe neuronal responses in monkeys and behavioral responses in patients using a new technique to test these cognitive controls. The new technique examines the neural substrate of working memory and movement preparation for predictive pursuit by using a memory-based task in macaque monkeys trained to pursue (go) or not pursue (no-go) according to a go/no-go cue, in a direction based on memory of a previously presented visual motion display. Single-unit task-related neuronal activity was examined in medial superior temporal cortex (MST), supplementary eye fields (SEF), caudal frontal eye fields (FEF), cerebellar dorsal vermis lobules VI–VII, caudal fastigial nuclei (cFN), and floccular region. Neuronal activity reflecting working memory of visual motion direction and go/no-go selection was found predominantly in SEF, cerebellar dorsal vermis and cFN, whereas movement preparation related signals were found predominantly in caudal FEF and the same cerebellar areas. Chemical inactivation produced effects consistent with differences in signals represented in each area. When applied to patients with Parkinson's disease (PD), the task revealed deficits in movement preparation but not working memory. In contrast, patients with frontal cortical or cerebellar dysfunction had high error rates, suggesting impaired working memory. We show how neuronal activity may be explained by models of retinal and extra-retinal interaction in target selection and predictive control and thus aid understanding of underlying pathophysiology. PMID:23515488

  20. Temporal dynamics of retinal and extraretinal signals in the FEFsem during smooth pursuit eye movements.

    PubMed

    Bakst, Leah; Fleuriet, Jérome; Mustari, Michael J

    2017-05-01

    Neurons in the smooth eye movement subregion of the frontal eye field (FEFsem) are known to play an important role in voluntary smooth pursuit eye movements. Underlying this function are projections to parietal and prefrontal visual association areas and subcortical structures, all known to play vital but differing roles in the execution of smooth pursuit. Additionally, the FEFsem has been shown to carry a diverse array of signals (e.g., eye velocity, acceleration, gain control). We hypothesized that distinct subpopulations of FEFsem neurons subserve these diverse functions and projections, and that the relative weights of retinal and extraretinal signals could form the basis for categorization of units. To investigate this, we used a step-ramp tracking task with a target blink to determine the relative contributions of retinal and extraretinal signals in individual FEFsem neurons throughout pursuit. We found that the contributions of retinal and extraretinal signals to neuronal activity and behavior change throughout the time course of pursuit. A clustering algorithm revealed three distinct neuronal subpopulations: cluster 1 was defined by a higher sensitivity to eye velocity, acceleration, and retinal image motion; cluster 2 had greater activity during blinks; and cluster 3 had significantly greater eye position sensitivity. We also performed a comparison with a sample of medial superior temporal neurons to assess similarities and differences between the two areas. Our results indicate the utility of simple tests such as the target blink for parsing the complex and multifaceted roles of cortical areas in behavior. NEW & NOTEWORTHY The frontal eye field (FEF) is known to play a critical role in volitional smooth pursuit, carrying a variety of signals that are distributed throughout the brain. This study used a novel application of a target blink task during step ramp tracking to determine, in combination with a clustering algorithm, the relative contributions of retinal and extraretinal signals to FEF activity and the extent to which these contributions could form the basis for a categorization of neurons. Copyright © 2017 the American Physiological Society.

  1. The engagement of cortical areas preceding exogenous vergence eye movements.

    PubMed

    Wojtczak-Kwaśniewska, Monika; Przekoracka-Krawczyk, Anna; Van der Lubbe, Rob H J

    2018-01-01

    Source analyses on event related potentials (ERPs) derived from the electroencephalogram (EEG) were performed to examine the respective roles of cortical areas preceding exogenously triggered saccades, combined convergences, and combined divergences. All eye movements were triggered by the offset of a central fixation light emitting diode (LED) and the onset of a lateral LED at various depths in an otherwise fully darkened room. Our analyses revealed that three source pairs, two located in the frontal lobe-the frontal eye fields (FEF) and an anterior frontal area-, and one located within the occipital cortex, can account for 99.2% of the observed ERPs. Overall, the comparison between source activities revealed the largest activity in the occipital cortex, while no difference in activity between FEF and the anterior frontal area was obtained. For all sources, increased activity was observed for combined vergences, especially combined convergences, relative to saccades. Behavioral results revealed that onset latencies were longest for combined convergences, intermediate for combined divergences, and the shortest for saccades. Together, these findings fit within a perspective in which both occipital and frontal areas play an important role in retinal disparity detection. In the case of saccades and combined divergences stimulus-locked activity was larger than response-locked activity, while no difference between stimulus- and response-locked activity was observed for combined convergences. These findings seem to imply that the electrophysiological activity preceding exogenous eye movements consists of a sensory-related part that is under cortical control, while subcortical structures may be held responsible for final execution.

  2. Parietal blood oxygenation level-dependent response evoked by covert visual search reflects set-size effect in monkeys.

    PubMed

    Atabaki, A; Marciniak, K; Dicke, P W; Karnath, H-O; Thier, P

    2014-03-01

    Distinguishing a target from distractors during visual search is crucial for goal-directed behaviour. The more distractors that are presented with the target, the larger is the subject's error rate. This observation defines the set-size effect in visual search. Neurons in areas related to attention and eye movements, like the lateral intraparietal area (LIP) and frontal eye field (FEF), diminish their firing rates when the number of distractors increases, in line with the behavioural set-size effect. Furthermore, human imaging studies that have tried to delineate cortical areas modulating their blood oxygenation level-dependent (BOLD) response with set size have yielded contradictory results. In order to test whether BOLD imaging of the rhesus monkey cortex yields results consistent with the electrophysiological findings and, moreover, to clarify if additional other cortical regions beyond the two hitherto implicated are involved in this process, we studied monkeys while performing a covert visual search task. When varying the number of distractors in the search task, we observed a monotonic increase in error rates when search time was kept constant as was expected if monkeys resorted to a serial search strategy. Visual search consistently evoked robust BOLD activity in the monkey FEF and a region in the intraparietal sulcus in its lateral and middle part, probably involving area LIP. Whereas the BOLD response in the FEF did not depend on set size, the LIP signal increased in parallel with set size. These results demonstrate the virtue of BOLD imaging in monkeys when trying to delineate cortical areas underlying a cognitive process like visual search. However, they also demonstrate the caution needed when inferring neural activity from BOLD activity. © 2013 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.

  3. Smooth-pursuit eye-movement deficits with chemical lesions in macaque nucleus reticularis tegmenti pontis.

    PubMed

    Suzuki, D A; Yamada, T; Hoedema, R; Yee, R D

    1999-09-01

    Anatomic and neuronal recordings suggest that the nucleus reticularis tegmenti pontis (NRTP) of macaques may be a major pontine component of a cortico-ponto-cerebellar pathway that subserves the control of smooth-pursuit eye movements. The existence of such a pathway was implicated by the lack of permanent pursuit impairment after bilateral lesions in the dorsolateral pontine nucleus. To provide more direct evidence that NRTP is involved with regulating smooth-pursuit eye movements, chemical lesions were made in macaque NRTP by injecting either lidocaine or ibotenic acid. Injection sites first were identified by the recording of smooth-pursuit-related modulations in neuronal activity. The resulting lesions caused significant deficits in both the maintenance and the initiation of smooth-pursuit eye movements. After lesion formation, the gain of constant-velocity, maintained smooth-pursuit eye movements decreased, on the average, by 44%. Recovery of the ability to maintain smooth-pursuit eye movements occurred over approximately 3 days when maintained pursuit gains attained normal values. The step-ramp, "Rashbass" task was used to investigate the effects of the lesions on the initiation of smooth-pursuit eye movements. Eye accelerations averaged over the initial 80 ms of pursuit initiation were determined and found to be decremented, on the average, by 48% after the administration of ibotenic acid. Impairments in the initiation and maintenance of smooth-pursuit eye movements were directional in nature. Upward pursuit seemed to be the most vulnerable and was impaired in all cases independent of lesioning agent and type of pursuit investigated. Downward smooth pursuit seemed more resistant to the effects of chemical lesions in NRTP. Impairments in horizontal tracking were observed with examples of deficits in ipsilaterally and contralaterally directed pursuit. The results provide behavioral support for the physiologically and anatomic-based conclusion that NRTP is a component of a cortico-ponto-cerebellar circuit that presumably involves the pursuit area of the frontal eye field (FEF) and projects to ocular motor-related areas of the cerebellum. This FEF-NRTP-cerebellum path would parallel a middle and medial superior temporal cerebral cortical area-dorsolateral pontine nucleus-cerebellum pathway also known to be involved with regulating smooth-pursuit eye movements.

  4. Visual Contrast Sensitivity Improvement by Right Frontal High-Beta Activity Is Mediated by Contrast Gain Mechanisms and Influenced by Fronto-Parietal White Matter Microstructure

    PubMed Central

    Quentin, Romain; Elkin Frankston, Seth; Vernet, Marine; Toba, Monica N.; Bartolomeo, Paolo; Chanes, Lorena; Valero-Cabré, Antoni

    2016-01-01

    Behavioral and electrophysiological studies in humans and non-human primates have correlated frontal high-beta activity with the orienting of endogenous attention and shown the ability of the latter function to modulate visual performance. We here combined rhythmic transcranial magnetic stimulation (TMS) and diffusion imaging to study the relation between frontal oscillatory activity and visual performance, and we associated these phenomena to a specific set of white matter pathways that in humans subtend attentional processes. High-beta rhythmic activity on the right frontal eye field (FEF) was induced with TMS and its causal effects on a contrast sensitivity function were recorded to explore its ability to improve visual detection performance across different stimulus contrast levels. Our results show that frequency-specific activity patterns engaged in the right FEF have the ability to induce a leftward shift of the psychometric function. This increase in visual performance across different levels of stimulus contrast is likely mediated by a contrast gain mechanism. Interestingly, microstructural measures of white matter connectivity suggest a strong implication of right fronto-parietal connectivity linking the FEF and the intraparietal sulcus in propagating high-beta rhythmic signals across brain networks and subtending top-down frontal influences on visual performance. PMID:25899709

  5. Positive Association of Video Game Playing with Left Frontal Cortical Thickness in Adolescents

    PubMed Central

    Kühn, Simone; Lorenz, Robert; Banaschewski, Tobias; Barker, Gareth J.; Büchel, Christian; Conrod, Patricia J.; Flor, Herta; Garavan, Hugh; Ittermann, Bernd; Loth, Eva; Mann, Karl; Nees, Frauke; Artiges, Eric; Paus, Tomas; Rietschel, Marcella; Smolka, Michael N.; Ströhle, Andreas; Walaszek, Bernadetta; Schumann, Gunter; Heinz, Andreas; Gallinat, Jürgen

    2014-01-01

    Playing video games is a common recreational activity of adolescents. Recent research associated frequent video game playing with improvements in cognitive functions. Improvements in cognition have been related to grey matter changes in prefrontal cortex. However, a fine-grained analysis of human brain structure in relation to video gaming is lacking. In magnetic resonance imaging scans of 152 14-year old adolescents, FreeSurfer was used to estimate cortical thickness. Cortical thickness across the whole cortical surface was correlated with self-reported duration of video gaming (hours per week). A robust positive association between cortical thickness and video gaming duration was observed in left dorsolateral prefrontal cortex (DLPFC) and left frontal eye fields (FEFs). No regions showed cortical thinning in association with video gaming frequency. DLPFC is the core correlate of executive control and strategic planning which in turn are essential cognitive domains for successful video gaming. The FEFs are a key region involved in visuo-motor integration important for programming and execution of eye movements and allocation of visuo-spatial attention, processes engaged extensively in video games. The results may represent the biological basis of previously reported cognitive improvements due to video game play. Whether or not these results represent a-priori characteristics or consequences of video gaming should be studied in future longitudinal investigations. PMID:24633348

  6. Motor selection dynamics in FEF explain the reaction time variance of saccades to single targets

    PubMed Central

    Hauser, Christopher K; Zhu, Dantong; Stanford, Terrence R

    2018-01-01

    In studies of voluntary movement, a most elemental quantity is the reaction time (RT) between the onset of a visual stimulus and a saccade toward it. However, this RT demonstrates extremely high variability which, in spite of extensive research, remains unexplained. It is well established that, when a visual target appears, oculomotor activity gradually builds up until a critical level is reached, at which point a saccade is triggered. Here, based on computational work and single-neuron recordings from monkey frontal eye field (FEF), we show that this rise-to-threshold process starts from a dynamic initial state that already contains other incipient, internally driven motor plans, which compete with the target-driven activity to varying degrees. The ensuing conflict resolution process, which manifests in subtle covariations between baseline activity, build-up rate, and threshold, consists of fundamentally deterministic interactions, and explains the observed RT distributions while invoking only a small amount of intrinsic randomness. PMID:29652247

  7. Functional Connectivity of the Dorsal Attention Network Predicts Selective Attention in 4-7 year-old Girls.

    PubMed

    Rohr, Christiane S; Vinette, Sarah A; Parsons, Kari A L; Cho, Ivy Y K; Dimond, Dennis; Benischek, Alina; Lebel, Catherine; Dewey, Deborah; Bray, Signe

    2017-09-01

    Early childhood is a period of profound neural development and remodeling during which attention skills undergo rapid maturation. Attention networks have been extensively studied in the adult brain, yet relatively little is known about changes in early childhood, and their relation to cognitive development. We investigated the association between age and functional connectivity (FC) within the dorsal attention network (DAN) and the association between FC and attention skills in early childhood. Functional magnetic resonance imaging data was collected during passive viewing in 44 typically developing female children between 4 and 7 years whose sustained, selective, and executive attention skills were assessed. FC of the intraparietal sulcus (IPS) and the frontal eye fields (FEF) was computed across the entire brain and regressed against age. Age was positively associated with FC between core nodes of the DAN, the IPS and the FEF, and negatively associated with FC between the DAN and regions of the default-mode network. Further, controlling for age, FC between the IPS and FEF was significantly associated with selective attention. These findings add to our understanding of early childhood development of attention networks and suggest that greater FC within the DAN is associated with better selective attention skills. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  8. Cortical Coupling Reflects Bayesian Belief Updating in the Deployment of Spatial Attention.

    PubMed

    Vossel, Simone; Mathys, Christoph; Stephan, Klaas E; Friston, Karl J

    2015-08-19

    The deployment of visuospatial attention and the programming of saccades are governed by the inferred likelihood of events. In the present study, we combined computational modeling of psychophysical data with fMRI to characterize the computational and neural mechanisms underlying this flexible attentional control. Sixteen healthy human subjects performed a modified version of Posner's location-cueing paradigm in which the percentage of cue validity varied in time and the targets required saccadic responses. Trialwise estimates of the certainty (precision) of the prediction that the target would appear at the cued location were derived from a hierarchical Bayesian model fitted to individual trialwise saccadic response speeds. Trial-specific model parameters then entered analyses of fMRI data as parametric regressors. Moreover, dynamic causal modeling (DCM) was performed to identify the most likely functional architecture of the attentional reorienting network and its modulation by (Bayes-optimal) precision-dependent attention. While the frontal eye fields (FEFs), intraparietal sulcus, and temporoparietal junction (TPJ) of both hemispheres showed higher activity on invalid relative to valid trials, reorienting responses in right FEF, TPJ, and the putamen were significantly modulated by precision-dependent attention. Our DCM results suggested that the precision of predictability underlies the attentional modulation of the coupling of TPJ with FEF and the putamen. Our results shed new light on the computational architecture and neuronal network dynamics underlying the context-sensitive deployment of visuospatial attention. Spatial attention and its neural correlates in the human brain have been studied extensively with the help of fMRI and cueing paradigms in which the location of targets is pre-cued on a trial-by-trial basis. One aspect that has so far been neglected concerns the question of how the brain forms attentional expectancies when no a priori probability information is available but needs to be inferred from observations. This study elucidates the computational and neural mechanisms under which probabilistic inference governs attentional deployment. Our results show that Bayesian belief updating explains changes in cortical connectivity; in that directional influences from the temporoparietal junction on the frontal eye fields and the putamen were modulated by (Bayes-optimal) updates. Copyright © 2015 Vossel et al.

  9. A self-organizing model of perisaccadic visual receptive field dynamics in primate visual and oculomotor system.

    PubMed

    Mender, Bedeho M W; Stringer, Simon M

    2015-01-01

    We propose and examine a model for how perisaccadic visual receptive field dynamics, observed in a range of primate brain areas such as LIP, FEF, SC, V3, V3A, V2, and V1, may develop through a biologically plausible process of unsupervised visually guided learning. These dynamics are associated with remapping, which is the phenomenon where receptive fields anticipate the consequences of saccadic eye movements. We find that a neural network model using a local associative synaptic learning rule, when exposed to visual scenes in conjunction with saccades, can account for a range of associated phenomena. In particular, our model demonstrates predictive and pre-saccadic remapping, responsiveness shifts around the time of saccades, and remapping from multiple directions.

  10. A self-organizing model of perisaccadic visual receptive field dynamics in primate visual and oculomotor system

    PubMed Central

    Mender, Bedeho M. W.; Stringer, Simon M.

    2015-01-01

    We propose and examine a model for how perisaccadic visual receptive field dynamics, observed in a range of primate brain areas such as LIP, FEF, SC, V3, V3A, V2, and V1, may develop through a biologically plausible process of unsupervised visually guided learning. These dynamics are associated with remapping, which is the phenomenon where receptive fields anticipate the consequences of saccadic eye movements. We find that a neural network model using a local associative synaptic learning rule, when exposed to visual scenes in conjunction with saccades, can account for a range of associated phenomena. In particular, our model demonstrates predictive and pre-saccadic remapping, responsiveness shifts around the time of saccades, and remapping from multiple directions. PMID:25717301

  11. Decoding Saccadic Directions Using Epidural ECoG in Non-Human Primates

    PubMed Central

    2017-01-01

    A brain-computer interface (BCI) can be used to restore some communication as an alternative interface for patients suffering from locked-in syndrome. However, most BCI systems are based on SSVEP, P300, or motor imagery, and a diversity of BCI protocols would be needed for various types of patients. In this paper, we trained the choice saccade (CS) task in 2 non-human primate monkeys and recorded the brain signal using an epidural electrocorticogram (eECoG) to predict eye movement direction. We successfully predicted the direction of the upcoming eye movement using a support vector machine (SVM) with the brain signals after the directional cue onset and before the saccade execution. The mean accuracies were 80% for 2 directions and 43% for 4 directions. We also quantified the spatial-spectro-temporal contribution ratio using SVM recursive feature elimination (RFE). The channels over the frontal eye field (FEF), supplementary eye field (SEF), and superior parietal lobule (SPL) area were dominantly used for classification. The α-band in the spectral domain and the time bins just after the directional cue onset and just before the saccadic execution were mainly useful for prediction. A saccade based BCI paradigm can be projected in the 2D space, and will hopefully provide an intuitive and convenient communication platform for users. PMID:28665058

  12. Effects of Working Memory Demand on Neural Mechanisms of Motor Response Selection and Control

    PubMed Central

    Barber, Anita D.; Caffo, Brian S.; Pekar, James J.; Mostofsky, Stewart H.

    2013-01-01

    Inhibitory control commonly recruits a number of frontal regions: pre-supplementary motor area (pre-SMA), frontal eye fields (FEFs), and right-lateralized posterior inferior frontal gyrus (IFG), dorsal anterior insula (DAI), dorsolateral prefrontal cortex (DLPFC), and inferior frontal junction (IFJ). These regions may directly implement inhibitory motor control or may be more generally involved in executive control functions. Two go/no-go tasks were used to distinguish regions specifically recruited for inhibition from those that additionally show increased activity with working memory demand. The pre-SMA and IFG were recruited for inhibition in both tasks and did not have greater activation for working memory demand on no-go trials, consistent with a role in inhibitory control. Activation in pre-SMA also responded to response selection demand and was increased with working memory on go trials specifically. The bilateral FEF and right DAI were commonly active for no-go trials. The FEF was also recruited to a greater degree with working memory demand on go trials and may bias top–down information when stimulus–response mappings change. The DAI, additionally responded to increased working memory demand on both go and no-go trials and may be involved in accessing sustained task information, alerting, or autonomic changes when cognitive demands increase. DLPFC activation was consistent with a role in working memory retrieval on both go and no-go trials. The inferior frontal junction, on the other hand, had greater activation with working memory specifically for no-go trials and may detect salient stimuli when the task requires frequent updating of working memory representations. PMID:23530923

  13. Decoding Saccadic Directions Using Epidural ECoG in Non-Human Primates.

    PubMed

    Lee, Jeyeon; Choi, Hoseok; Lee, Seho; Cho, Baek Hwan; Ahn, Kyoung Ha; Kim, In Young; Lee, Kyoung Min; Jang, Dong Pyo

    2017-08-01

    A brain-computer interface (BCI) can be used to restore some communication as an alternative interface for patients suffering from locked-in syndrome. However, most BCI systems are based on SSVEP, P300, or motor imagery, and a diversity of BCI protocols would be needed for various types of patients. In this paper, we trained the choice saccade (CS) task in 2 non-human primate monkeys and recorded the brain signal using an epidural electrocorticogram (eECoG) to predict eye movement direction. We successfully predicted the direction of the upcoming eye movement using a support vector machine (SVM) with the brain signals after the directional cue onset and before the saccade execution. The mean accuracies were 80% for 2 directions and 43% for 4 directions. We also quantified the spatial-spectro-temporal contribution ratio using SVM recursive feature elimination (RFE). The channels over the frontal eye field (FEF), supplementary eye field (SEF), and superior parietal lobule (SPL) area were dominantly used for classification. The α-band in the spectral domain and the time bins just after the directional cue onset and just before the saccadic execution were mainly useful for prediction. A saccade based BCI paradigm can be projected in the 2D space, and will hopefully provide an intuitive and convenient communication platform for users. © 2017 The Korean Academy of Medical Sciences.

  14. FEFsem neuronal response during combined volitional and reflexive pursuit.

    PubMed

    Bakst, Leah; Fleuriet, Jérome; Mustari, Michael J

    2017-05-01

    Although much is known about volitional and reflexive smooth eye movements individually, much less is known about how they are coordinated. It is hypothesized that separate cortico-ponto-cerebellar loops subserve these different types of smooth eye movements. Specifically, the MT-MST-DLPN pathway is thought to be critical for ocular following eye movements, whereas the FEF-NRTP pathway is understood to be vital for volitional smooth pursuit. However, the role that these loops play in combined volitional and reflexive behavior is unknown. We used a large, textured background moving in conjunction with a small target spot to investigate the eye movements evoked by a combined volitional and reflexive pursuit task. We also assessed the activity of neurons in the smooth eye movement subregion of the frontal eye field (FEFsem). We hypothesized that the pursuit system would show less contribution from the volitional pathway in this task, owing to the increased involvement of the reflexive pathway. In accordance with this hypothesis, a majority of FEFsem neurons (63%) were less active during pursuit maintenance in a combined volitional and reflexive pursuit task than during purely volitional pursuit. Interestingly and surprisingly, the neuronal response to the addition of the large-field motion was highly correlated with the neuronal response to a target blink. This suggests that FEFsem neuronal responses to these different perturbations-whether the addition or subtraction of retinal input-may be related. We conjecture that these findings are due to changing weights of both the volitional and reflexive pathways, as well as retinal and extraretinal signals.

  15. FEFsem neuronal response during combined volitional and reflexive pursuit

    PubMed Central

    Bakst, Leah; Fleuriet, Jérome; Mustari, Michael J.

    2017-01-01

    Although much is known about volitional and reflexive smooth eye movements individually, much less is known about how they are coordinated. It is hypothesized that separate cortico-ponto-cerebellar loops subserve these different types of smooth eye movements. Specifically, the MT-MST-DLPN pathway is thought to be critical for ocular following eye movements, whereas the FEF-NRTP pathway is understood to be vital for volitional smooth pursuit. However, the role that these loops play in combined volitional and reflexive behavior is unknown. We used a large, textured background moving in conjunction with a small target spot to investigate the eye movements evoked by a combined volitional and reflexive pursuit task. We also assessed the activity of neurons in the smooth eye movement subregion of the frontal eye field (FEFsem). We hypothesized that the pursuit system would show less contribution from the volitional pathway in this task, owing to the increased involvement of the reflexive pathway. In accordance with this hypothesis, a majority of FEFsem neurons (63%) were less active during pursuit maintenance in a combined volitional and reflexive pursuit task than during purely volitional pursuit. Interestingly and surprisingly, the neuronal response to the addition of the large-field motion was highly correlated with the neuronal response to a target blink. This suggests that FEFsem neuronal responses to these different perturbations—whether the addition or subtraction of retinal input—may be related. We conjecture that these findings are due to changing weights of both the volitional and reflexive pathways, as well as retinal and extraretinal signals. PMID:28538993

  16. Gender differences in brain structure and resting-state functional connectivity related to narcissistic personality.

    PubMed

    Yang, Wenjing; Cun, Lingli; Du, Xue; Yang, Junyi; Wang, Yanqiu; Wei, Dongtao; Zhang, Qinglin; Qiu, Jiang

    2015-06-25

    Although cognitive and personality studies have observed gender differences in narcissism, the neural bases of these differences remain unknown. The current study combined the voxel-based morphometry and resting state functional connectivity (rsFC) analyses to explore the sex-specific neural basis of narcissistic personality. The VBM results showed that the relationship between narcissistic personality and regional gray matter volume (rGMV) differed between sexes. Narcissistic scores had a significant positive correlation with the rGMV of the right SPL in females, but not in males. Further analyses were conducted to investigate the sex-specific relationship between rsFC and narcissism, using right SPL/frontal eye fields (FEF) as the seed regions (key nodes of the dorsal attention network, DAN). Interestingly, decreased anticorrelations between the right SPL/FEF and areas of the precuneus and middle frontal gyrus (key nodes of the the default mode network, DMN) were associated with higher narcissistic personality scores in males, whereas females showed the opposite tendency. The findings indicate that gender differences in narcissism may be associated with differences in the intrinsic and dynamic interplay between the internally-directed DMN and the externally-directed TPN. Morphometry and functional connectivity analyses can enhance our understanding of the neural basis of sex-specific narcissism.

  17. Gender differences in brain structure and resting-state functional connectivity related to narcissistic personality

    PubMed Central

    Yang, Wenjing; Cun, Lingli; Du, Xue; Yang, Junyi; Wang, Yanqiu; Wei, Dongtao; Zhang, Qinglin; Qiu, Jiang

    2015-01-01

    Although cognitive and personality studies have observed gender differences in narcissism, the neural bases of these differences remain unknown. The current study combined the voxel-based morphometry and resting state functional connectivity (rsFC) analyses to explore the sex-specific neural basis of narcissistic personality. The VBM results showed that the relationship between narcissistic personality and regional gray matter volume (rGMV) differed between sexes. Narcissistic scores had a significant positive correlation with the rGMV of the right SPL in females, but not in males. Further analyses were conducted to investigate the sex-specific relationship between rsFC and narcissism, using right SPL/frontal eye fields (FEF) as the seed regions (key nodes of the dorsal attention network, DAN). Interestingly, decreased anticorrelations between the right SPL/FEF and areas of the precuneus and middle frontal gyrus (key nodes of the the default mode network, DMN) were associated with higher narcissistic personality scores in males, whereas females showed the opposite tendency. The findings indicate that gender differences in narcissism may be associated with differences in the intrinsic and dynamic interplay between the internally-directed DMN and the externally-directed TPN. Morphometry and functional connectivity analyses can enhance our understanding of the neural basis of sex-specific narcissism. PMID:26109334

  18. Impaired smooth-pursuit in Parkinson's disease: normal cue-information memory, but dysfunction of extra-retinal mechanisms for pursuit preparation and execution

    PubMed Central

    Fukushima, Kikuro; Ito, Norie; Barnes, Graham R; Onishi, Sachiyo; Kobayashi, Nobuyoshi; Takei, Hidetoshi; Olley, Peter M; Chiba, Susumu; Inoue, Kiyoharu; Warabi, Tateo

    2015-01-01

    While retinal image motion is the primary input for smooth-pursuit, its efficiency depends on cognitive processes including prediction. Reports are conflicting on impaired prediction during pursuit in Parkinson's disease. By separating two major components of prediction (image motion direction memory and movement preparation) using a memory-based pursuit task, and by comparing tracking eye movements with those during a simple ramp-pursuit task that did not require visual memory, we examined smooth-pursuit in 25 patients with Parkinson's disease and compared the results with 14 age-matched controls. In the memory-based pursuit task, cue 1 indicated visual motion direction, whereas cue 2 instructed the subjects to prepare to pursue or not to pursue. Based on the cue-information memory, subjects were asked to pursue the correct spot from two oppositely moving spots or not to pursue. In 24/25 patients, the cue-information memory was normal, but movement preparation and execution were impaired. Specifically, unlike controls, most of the patients (18/24 = 75%) lacked initial pursuit during the memory task and started tracking the correct spot by saccades. Conversely, during simple ramp-pursuit, most patients (83%) exhibited initial pursuit. Popping-out of the correct spot motion during memory-based pursuit was ineffective for enhancing initial pursuit. The results were similar irrespective of levodopa/dopamine agonist medication. Our results indicate that the extra-retinal mechanisms of most patients are dysfunctional in initiating memory-based (not simple ramp) pursuit. A dysfunctional pursuit loop between frontal eye fields (FEF) and basal ganglia may contribute to the impairment of extra-retinal mechanisms, resulting in deficient pursuit commands from the FEF to brainstem. PMID:25825544

  19. Generation of Elliptically Polarized Terahertz Waves from Antiferromagnetic Sandwiched Structure.

    PubMed

    Zhou, Sheng; Zhang, Qiang; Fu, Shu-Fang; Wang, Xuan-Zhang; Song, Yu-Ling; Wang, Xiang-Guang; Qu, Xiu-Rong

    2018-04-01

    The generation of elliptically polarized electromagnetic wave of an antiferromagnetic (AF)/dielectric sandwiched structure in the terahertz range is studied. The frequency and external magnetic field can change the AF optical response, resulting in the generation of elliptical polarization. An especially useful geometry with high levels of the generation of elliptical polarization is found in the case where an incident electromagnetic wave perpendicularly illuminates the sandwiched structure, the AF anisotropy axis is vertical to the wave-vector and the external magnetic field is pointed along the wave-vector. In numerical calculations, the AF layer is FeF2 and the dielectric layers are ZnF2. Although the effect originates from the AF layer, it can be also influenced by the sandwiched structure. We found that the ZnF2/FeF2/ZnF2 structure possesses optimal rotation of the principal axis and ellipticity, which can reach up to about thrice that of a single FeF2 layer.

  20. The theoretical link between voltage loss, reduction in field enhancement factor, and Fowler-Nordheim-plot saturation

    NASA Astrophysics Data System (ADS)

    Forbes, Richard G.

    2017-03-01

    With a large-area field electron emitter, when an individual post-like emitter is sufficiently resistive, and current through it is sufficiently large, then voltage loss occurs along it. This letter provides a simple analytical and conceptual demonstration that this voltage loss is directly and inextricably linked to a reduction in the field enhancement factor (FEF) at the post apex. A formula relating apex-FEF reduction to this voltage loss was obtained in the paper by Minoux et al. [Nano Lett. 5, 2135 (2005)] by fitting to numerical results from a Laplace solver. This letter derives the same formula analytically, by using a "floating sphere" model. The analytical proof brings out the underlying physics more clearly and shows that the effect is a general phenomenon, related to reduction in the magnitude of the surface charge in the most protruding parts of an emitter. Voltage-dependent FEF-reduction is one cause of "saturation" in Fowler-Nordheim (FN) plots. Another is a voltage-divider effect, due to measurement-circuit resistance. An integrated theory of both effects is presented. Both together, or either by itself, can cause saturation. Experimentally, if saturation occurs but voltage loss is small (<20 V, say), then saturation is more probably due to FEF-reduction than voltage division. In this case, existing treatments of electrostatic interaction ("shielding") between closely spaced emitters may need modification. Other putative causes of saturation exist, so the present theory is a partial story. Its extension seems possible and could lead to a more general physical understanding of the causes of FN-plot saturation.

  1. Impaired smooth-pursuit in Parkinson's disease: normal cue-information memory, but dysfunction of extra-retinal mechanisms for pursuit preparation and execution.

    PubMed

    Fukushima, Kikuro; Ito, Norie; Barnes, Graham R; Onishi, Sachiyo; Kobayashi, Nobuyoshi; Takei, Hidetoshi; Olley, Peter M; Chiba, Susumu; Inoue, Kiyoharu; Warabi, Tateo

    2015-03-01

    While retinal image motion is the primary input for smooth-pursuit, its efficiency depends on cognitive processes including prediction. Reports are conflicting on impaired prediction during pursuit in Parkinson's disease. By separating two major components of prediction (image motion direction memory and movement preparation) using a memory-based pursuit task, and by comparing tracking eye movements with those during a simple ramp-pursuit task that did not require visual memory, we examined smooth-pursuit in 25 patients with Parkinson's disease and compared the results with 14 age-matched controls. In the memory-based pursuit task, cue 1 indicated visual motion direction, whereas cue 2 instructed the subjects to prepare to pursue or not to pursue. Based on the cue-information memory, subjects were asked to pursue the correct spot from two oppositely moving spots or not to pursue. In 24/25 patients, the cue-information memory was normal, but movement preparation and execution were impaired. Specifically, unlike controls, most of the patients (18/24 = 75%) lacked initial pursuit during the memory task and started tracking the correct spot by saccades. Conversely, during simple ramp-pursuit, most patients (83%) exhibited initial pursuit. Popping-out of the correct spot motion during memory-based pursuit was ineffective for enhancing initial pursuit. The results were similar irrespective of levodopa/dopamine agonist medication. Our results indicate that the extra-retinal mechanisms of most patients are dysfunctional in initiating memory-based (not simple ramp) pursuit. A dysfunctional pursuit loop between frontal eye fields (FEF) and basal ganglia may contribute to the impairment of extra-retinal mechanisms, resulting in deficient pursuit commands from the FEF to brainstem. © 2015 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of the American Physiological Society and The Physiological Society.

  2. Interplay between morphological and shielding effects in field emission via Schwarz-Christoffel transformation

    NASA Astrophysics Data System (ADS)

    Marcelino, Edgar; de Assis, Thiago A.; de Castilho, Caio M. C.

    2018-03-01

    It is well known that sufficiently strong electrostatic fields are able to change the morphology of Large Area Field Emitters (LAFEs). This phenomenon affects the electrostatic interactions between adjacent sites on a LAFE during field emission and may lead to several consequences, such as: the emitter's degradation, diffusion of absorbed particles on the emitter's surface, deflection due to electrostatic forces, and mechanical stress. These consequences are undesirable for technological applications, since they may significantly affect the macroscopic current density on the LAFE. Despite the technological importance, these processes are not completely understood yet. Moreover, the electrostatic effects due to the proximity between emitters on a LAFE may compete with the morphological ones. The balance between these effects may lead to a non trivial behavior in the apex-Field Enhancement Factor (FEF). The present work intends to study the interplay between proximity and morphological effects by studying a model amenable for an analytical treatment. In order to do that, a conducting system under an external electrostatic field, with a profile limited by two mirror-reflected triangular protrusions on an infinite line, is considered. The FEF near the apex of each emitter is obtained as a function of their shape and the distance between them via a Schwarz-Christoffel transformation. Our results suggest that a tradeoff between morphological and proximity effects on a LAFE may provide an explanation for the observed reduction of the local FEF and its variation at small distances between the emitter sites.

  3. A critical role of temporoparietal junction in the integration of top-down and bottom-up attentional control

    PubMed Central

    Wu, Qiong; Chang, Chi-Fu; Xi, Sisi; Huang, I-Wen; Liu, Zuxiang; Juan, Chi-Hung; Wu, Yanhong; Fan, Jin

    2015-01-01

    Information processing can be biased toward behaviorally relevant and salient stimuli by top-down (goal-directed) and bottom-up (stimulus-driven) attentional control processes. However, the neural basis underlying the integration of these processes is not well understood. We employed functional magnetic resonance imaging and transcranial direct-current stimulation (tDCS) in humans to examine the brain mechanisms underlying the interaction between these two processes. We manipulated the cognitive load involved in top-down processing and stimulus surprise involved in bottom-up processing in a factorial design by combining a majority function task and an oddball paradigm. We found that high cognitive load and high surprise level were associated with prolonged reaction time compared to low cognitive load and low surprise level, with a synergistic interaction effect which was accompanied by a greater deactivation of bilateral temporoparietal junction (TPJ). In addition, the TPJ displayed negative functional connectivity with right middle occipital gyrus involved in bottom-up processing (modulated by the interaction effect) and the right frontal eye field (FEF) involved in top-down control. The enhanced negative functional connectivity between the TPJ and right FEF was accompanied by a larger behavioral interaction effect across subjects. Application of cathodal tDCS over the right TPJ eliminated the interaction effect. These results suggest that the TPJ plays a critical role in processing bottom-up information for top-down control of attention. PMID:26308973

  4. Predictors of Full Enteral Feeding Achievement in Very Low Birth Weight Infants

    PubMed Central

    Corvaglia, Luigi; Fantini, Maria Pia; Aceti, Arianna; Gibertoni, Dino; Rucci, Paola; Baronciani, Dante; Faldella, Giacomo

    2014-01-01

    Background To elucidate the role of prenatal, neonatal and early postnatal variables in influencing the achievement of full enteral feeding (FEF) in very low birth weight (VLBW) infants and to determine whether neonatal intensive care units (NICUs) differ in this outcome. Methods Population-based retrospective cohort study using data on 1,864 VLBW infants drawn from the “Emilia-Romagna Perinatal Network” Registry from 2004 to 2009. The outcome of interest was time to FEF achievement. Eleven prenatal, neonatal and early postnatal variables and the study NICUs were selected as potential predictors of time to FEF. Parametric survival analysis was used to model time to FEF as a function of the predictors. Marginal effects were used to obtain adjusted estimates of median time to FEF for specific subgroups of infants. Results Lower gestational age, exclusive formula feeding, higher CRIB II score, maternal hypertension, cesarean delivery, SGA and PDA predicted delayed FEF. NICUs proved to be heterogeneous in terms of FEF achievement. Newborns with PDA had a 4.2 days longer predicted median time to FEF compared to those without PDA; newborns exclusively formula-fed had a 1.4 days longer time to FEF compared to those fed human milk. Conclusions The results of our study suggest that time to FEF is influenced by clinical variables and NICU-specific practices. Knowledge of the variables associated with delayed/earlier FEF achievement could help in improving specific aspects of routine clinical management of VLBW infants and to reduce practice variability. PMID:24647523

  5. Optical properties of antiferromagnetic/ion-crystal superlattices

    NASA Astrophysics Data System (ADS)

    Ta, Jin-Xing; Song, Yu-Ling; Wang, Xuan-Zhang

    2012-01-01

    Transmission, refraction and absorption properties of an antiferromagnetic/ion-crystal superlattice are investigated. The transmission spectra based on FeF2/TlBr superlattices reveal that there exist two intriguing guided modes in a wide stop band. Additionally, FeF2/TlBr superlattices possess either the negative refraction or the quasi left-handedness, or even simultaneously hold them at certain frequencies of two guided modes, which require both negative magnetic permeability of antiferromagnetic layers and negative permittivity of ion-crystal layers. Frequency regimes of the guided modes will be dependent on the magnitude of the external magnetic field. Therefore, handedness and refraction properties of the system can be manipulated by modifying the external magnetic field. Absorption spectra exhibit that absorption corresponding to guided modes is noticeable.

  6. An fMRI Study of the Neural Systems Involved in Visually Cued Auditory Top-Down Spatial and Temporal Attention

    PubMed Central

    Li, Chunlin; Chen, Kewei; Han, Hongbin; Chui, Dehua; Wu, Jinglong

    2012-01-01

    Top-down attention to spatial and temporal cues has been thoroughly studied in the visual domain. However, because the neural systems that are important for auditory top-down temporal attention (i.e., attention based on time interval cues) remain undefined, the differences in brain activity between directed attention to auditory spatial location (compared with time intervals) are unclear. Using fMRI (magnetic resonance imaging), we measured the activations caused by cue-target paradigms by inducing the visual cueing of attention to an auditory target within a spatial or temporal domain. Imaging results showed that the dorsal frontoparietal network (dFPN), which consists of the bilateral intraparietal sulcus and the frontal eye field, responded to spatial orienting of attention, but activity was absent in the bilateral frontal eye field (FEF) during temporal orienting of attention. Furthermore, the fMRI results indicated that activity in the right ventrolateral prefrontal cortex (VLPFC) was significantly stronger during spatial orienting of attention than during temporal orienting of attention, while the DLPFC showed no significant differences between the two processes. We conclude that the bilateral dFPN and the right VLPFC contribute to auditory spatial orienting of attention. Furthermore, specific activations related to temporal cognition were confirmed within the superior occipital gyrus, tegmentum, motor area, thalamus and putamen. PMID:23166800

  7. Spin pumping and inverse spin Hall voltages from dynamical antiferromagnets

    NASA Astrophysics Data System (ADS)

    Johansen, Øyvind; Brataas, Arne

    2017-06-01

    Dynamical antiferromagnets can pump spins into adjacent conductors. The high antiferromagnetic resonance frequencies represent a challenge for experimental detection, but magnetic fields can reduce these resonance frequencies. We compute the ac and dc inverse spin Hall voltages resulting from dynamical spin excitations as a function of a magnetic field along the easy axis and the polarization of the driving ac magnetic field perpendicular to the easy axis. We consider the insulating antiferromagnets MnF2,FeF2, and NiO. Near the spin-flop transition, there is a significant enhancement of the dc spin pumping and inverse spin Hall voltage for the uniaxial antiferromagnets MnF2 and FeF2. In the uniaxial antiferromagnets it is also found that the ac spin pumping is independent of the external magnetic field when the driving field has the optimal circular polarization. In the biaxial NiO, the voltages are much weaker, and there is no spin-flop enhancement of the dc component.

  8. fMRI evidence for sensorimotor transformations in human cortex during smooth pursuit eye movements.

    PubMed

    Kimmig, H; Ohlendorf, S; Speck, O; Sprenger, A; Rutschmann, R M; Haller, S; Greenlee, M W

    2008-01-01

    Smooth pursuit eye movements (SP) are driven by moving objects. The pursuit system processes the visual input signals and transforms this information into an oculomotor output signal. Despite the object's movement on the retina and the eyes' movement in the head, we are able to locate the object in space implying coordinate transformations from retinal to head and space coordinates. To test for the visual and oculomotor components of SP and the possible transformation sites, we investigated three experimental conditions: (I) fixation of a stationary target with a second target moving across the retina (visual), (II) pursuit of the moving target with the second target moving in phase (oculomotor), (III) pursuit of the moving target with the second target remaining stationary (visuo-oculomotor). Precise eye movement data were simultaneously measured with the fMRI data. Visual components of activation during SP were located in the motion-sensitive, temporo-parieto-occipital region MT+ and the right posterior parietal cortex (PPC). Motor components comprised more widespread activation in these regions and additional activations in the frontal and supplementary eye fields (FEF, SEF), the cingulate gyrus and precuneus. The combined visuo-oculomotor stimulus revealed additional activation in the putamen. Possible transformation sites were found in MT+ and PPC. The MT+ activation evoked by the motion of a single visual dot was very localized, while the activation of the same single dot motion driving the eye was rather extended across MT+. The eye movement information appeared to be dispersed across the visual map of MT+. This could be interpreted as a transfer of the one-dimensional eye movement information into the two-dimensional visual map. Potentially, the dispersed information could be used to remap MT+ to space coordinates rather than retinal coordinates and to provide the basis for a motor output control. A similar interpretation holds for our results in the PPC region.

  9. Frontoparietal Activation During Visual Conjunction Search: Effects of Bottom-up Guidance and Adult Age

    PubMed Central

    Madden, David J.; Parks, Emily L.; Tallman, Catherine W.; Boylan, Maria A.; Hoagey, David A.; Cocjin, Sally B.; Johnson, Micah A.; Chou, Ying-hui; Potter, Guy G.; Chen, Nan-kuei; Packard, Lauren E.; Siciliano, Rachel E.; Monge, Zachary A.; Diaz, Michele T.

    2016-01-01

    We conducted functional magnetic resonance imaging (fMRI) with a visual search paradigm to test the hypothesis that aging is associated with increased frontoparietal involvement in both target detection and bottom-up attentional guidance (featural salience). Participants were 68 healthy adults, distributed continuously across 19-78 years of age. Frontoparietal regions of interest (ROIs) were defined from resting-state scans obtained prior to task-related fMRI. The search target was defined by a conjunction of color and orientation. Each display contained one item that was larger than the others (i.e., a size singleton) but was not informative regarding target identity. Analyses of search reaction time (RT) indicated that bottom-up attentional guidance from the size singleton (when coincident with the target) was relatively constant as a function of age. Frontoparietal fMRI activation related to target detection was constant as a function of age, as was the reduction in activation associated with salient targets. However, for individuals 35 years of age and older, engagement of the left frontal eye field (FEF) in bottom-up guidance was more prominent than for younger individuals. Further, the age-related differences in left FEF activation were a consequence of decreasing resting-state functional connectivity in visual sensory regions. These findings indicate that age-related compensatory effects may be expressed in the relation between activation and behavior, rather than in the magnitude of activation, and that relevant changes in the activation-RT relation may begin at a relatively early point in adulthood. PMID:28052456

  10. Comparison of Classifiers for Decoding Sensory and Cognitive Information from Prefrontal Neuronal Populations

    PubMed Central

    Astrand, Elaine; Enel, Pierre; Ibos, Guilhem; Dominey, Peter Ford; Baraduc, Pierre; Ben Hamed, Suliann

    2014-01-01

    Decoding neuronal information is important in neuroscience, both as a basic means to understand how neuronal activity is related to cerebral function and as a processing stage in driving neuroprosthetic effectors. Here, we compare the readout performance of six commonly used classifiers at decoding two different variables encoded by the spiking activity of the non-human primate frontal eye fields (FEF): the spatial position of a visual cue, and the instructed orientation of the animal's attention. While the first variable is exogenously driven by the environment, the second variable corresponds to the interpretation of the instruction conveyed by the cue; it is endogenously driven and corresponds to the output of internal cognitive operations performed on the visual attributes of the cue. These two variables were decoded using either a regularized optimal linear estimator in its explicit formulation, an optimal linear artificial neural network estimator, a non-linear artificial neural network estimator, a non-linear naïve Bayesian estimator, a non-linear Reservoir recurrent network classifier or a non-linear Support Vector Machine classifier. Our results suggest that endogenous information such as the orientation of attention can be decoded from the FEF with the same accuracy as exogenous visual information. All classifiers did not behave equally in the face of population size and heterogeneity, the available training and testing trials, the subject's behavior and the temporal structure of the variable of interest. In most situations, the regularized optimal linear estimator and the non-linear Support Vector Machine classifiers outperformed the other tested decoders. PMID:24466019

  11. A universal formula for the field enhancement factor

    NASA Astrophysics Data System (ADS)

    Biswas, Debabrata

    2018-04-01

    The field enhancement factor (FEF) is an important quantity in field emission calculations since the tunneling electron current depends very sensitively on its magnitude. The exact dependence of FEF on the emitter height h, the radius of curvature at the apex Ra, as well as the shape of the emitter base are still largely unknown. In this work, a universal formula for the field enhancement factor is derived for a single emitter. It depends on the ratio h/Ra and has the form γ a = ( 2 h / R a ) / [ α 1 ln ( 4 h / R a ) - α 2 ] , where α1 and α2 depend on the charge distribution on the emitter. Numerical results show that a simpler form γ a = ( 2 h / R a ) / [ ln ( 4 h / R a ) - α ] is equally valid with α depending on the emitter-base. Thus, for the hyperboloid, conical, and ellipsoid emitters, the value of α is 0, 0.88, and 2, while for the cylindrical base, α ≃ 2.6.

  12. Evidence of universal inverse-third power law for the shielding-induced fractional decrease in apex field enhancement factor at large spacings: a response via accurate Laplace-type calculations

    NASA Astrophysics Data System (ADS)

    de Assis, Thiago A.; Dall’Agnol, Fernando F.

    2018-05-01

    Numerical simulations are important when assessing the many characteristics of field emission related phenomena. In small simulation domains, the electrostatic effect from the boundaries is known to influence the calculated apex field enhancement factor (FEF) of the emitter, but no established dependence has been reported at present. In this work, we report the dependence of the lateral size, L, and the height, H, of the simulation domain on the apex-FEF of a single conducting ellipsoidal emitter. Firstly, we analyze the error, ε, in the calculation of the apex-FEF as a function of H and L. Importantly, our results show that the effects of H and L on ε are scale invariant, allowing one to predict ε for ratios L/h and H/h, where h is the height of the emitter. Next, we analyze the fractional change of the apex-FEF, δ, from a single emitter, , and a pair, . We show that small relative errors in (i.e. ), due to the finite domain size, are sufficient to alter the functional dependence , where c is the distance from the emitters in the pair. We show that obeys a recently proposed power law decay (Forbes 2016 J. Appl. Phys. 120 054302), at sufficiently large distances in the limit of infinite domain size (, say), which is not observed when using a long time established exponential decay (Bonard et al 2001 Adv. Mater. 13 184) or a more sophisticated fitting formula proposed recently by Harris et al (2015 AIP Adv. 5 087182). We show that the inverse-third power law functional dependence is respected for various systems like infinity arrays and small clusters of emitters with different shapes. Thus, , with m  =  3, is suggested to be a universal signature of the charge-blunting effect in small clusters or arrays, at sufficient large distances between emitters with any shape. These results improve the physical understanding of the field electron emission theory to accurately characterize emitters in small clusters or arrays.

  13. Li(x)FeF6 (x = 2, 3, 4) battery materials: structural, electronic and lithium diffusion properties.

    PubMed

    Schroeder, Melanie; Eames, Christopher; Tompsett, David A; Lieser, Georg; Islam, M Saiful

    2013-12-21

    Lithium iron fluoride materials have attracted recent interest as cathode materials for lithium ion batteries. The electrochemical properties of the high energy density Li(x)FeF6 (x = 2, 3, 4) materials have been evaluated using a combination of potential-based and DFT computational methods. Voltages of 6.1 V and 3.0 V are found for lithium intercalation from Li2FeF6 to α-Li3FeF6 and α-Li3FeF6 to Li4FeF6 respectively. The calculated density of states indicate that Li2FeF6 possesses metallic states that become strongly insulating after lithium intercalation to form α-Li3FeF6. The large energy gain associated with this metal-insulator transition is likely to contribute to the associated large voltage of 6.1 V. Molecular dynamics simulations of lithium diffusion in α-Li3FeF6 at typical battery operating temperatures indicate high lithium-ion mobility with low activation barriers. These results suggest the potential for good rate performance of lithium iron fluoride cathode materials.

  14. Perfluoropolyalkylether Oil Degradation: Inference of FeF3 Formation on Steel Surfaces under Boundary Conditions

    DTIC Science & Technology

    1985-08-01

    REPORT SD-TR-85-37 O,-) Lfl Perfluoropolyalkylether Oil Degradation: Inference of FeF 3 Formation on Steel Surfaces I under Boundary Conditions DAVID...S. TYPE OF REPORT & PERIOD COVERED PERFLUOROPOLYALKYLETHER OIL DEGRADATION: INFERENCE OF FeF3 FORMATION ON STEELSURFACES UNDER BOUNDARY CONDITIONS 0...number) Boundary conditions Oil Degradation Perfluoropolyalkylether FeF3 Wear test Lubrication .... 440C 20. ABSTRACT (Contlnue o 0 ,systes sI . I

  15. Anionic ordering and thermal properties of FeF3·3H2O.

    PubMed

    Burbano, Mario; Duttine, Mathieu; Borkiewicz, Olaf; Wattiaux, Alain; Demourgues, Alain; Salanne, Mathieu; Groult, Henri; Dambournet, Damien

    2015-10-05

    Iron fluoride trihydrate can be used to prepare iron hydroxyfluoride with the hexagonal-tungsten-bronze (HTB) type structure, a potential cathode material for batteries. To understand this phase transformation, a structural description of β-FeF3·3H2O is first performed by means of DFT calculations and Mössbauer spectroscopy. The structure of this compound consists of infinite chains of [FeF6]n and [FeF2(H2O)4]n. The decomposition of FeF3·3H2O induces a collapse and condensation of these chains, which lead to the stabilization, under specific conditions, of a hydroxyfluoride network FeF3-x(OH)x with the HTB structure. The release of H2O and HF was monitored by thermal analysis and physical characterizations during the decomposition of FeF3·3H2O. An average distribution of FeF4(OH)2 distorted octahedra in HTB-FeF3-x(OH)x was obtained subsequent to the thermal hydrolysis/olation of equatorial anionic positions involving F(-) and H2O. This study provides a clear understanding of the structure and thermal properties of FeF3·3H2O, a material that can potentially bridge the recycling of pickling sludge from the steel industry by preparing battery electrodes.

  16. Anionic ordering and thermal properties of FeF 3·3H 2O

    DOE PAGES

    Burbano, Mario; Duttine, Mathieu; Borkiewicz, Olaf; ...

    2015-09-17

    In this study, iron fluoride tri-hydrate can be used to prepare iron hydroxyfluoride with the Hexagonal-Tungsten-Bronze (HTB) type structure, a potential cathode material for batteries. To understand this phase transformation, a structural description of β-FeF 3·3H 2O is first performed by means of DFT calculations and Mössbauer spectroscopy. The structure of this compound consists of infinite chains of [FeF 6]n and [FeF 2(H2O) 4] n. The decomposition of FeF 3·3H 2O induces a collapse and condensation of these chains, which lead to the stabilization, under specific conditions, of a hydroxyfluoride network FeF 3-x(OH) x with the HTB structure. The releasemore » of H 2O and HF was monitored by thermal analysis and physical characterizations during the decomposition of FeF 3·3H 2O. An average distribution of FeF 4(OH) 2 distorted octahedra in HTB-FeF 3-x(OH) x was obtained subsequent to the thermal hydrolysis/olation of equatorial anionic positions involving F- and H 2O. This study provides a clear understanding of the structure and thermal properties of FeF 3·3H 2O, a material that can potentially bridge the recycling of pickling sludge from the steel industry by preparing battery electrodes.« less

  17. Exogenous vs. endogenous attention: Shifting the balance of fronto-parietal activity.

    PubMed

    Meyer, Kristin N; Du, Feng; Parks, Emily; Hopfinger, Joseph B

    2018-03-01

    Despite behavioral and electrophysiological evidence for dissociations between endogenous (voluntary) and exogenous (reflexive) attention, fMRI results have yet to consistently and clearly differentiate neural activation patterns between these two types of attention. This study specifically aimed to determine whether activity in the dorsal fronto-parietal network differed between endogenous and exogenous conditions. Participants performed a visual discrimination task in endogenous and exogenous attention conditions while undergoing fMRI scanning. Analyses revealed robust and bilateral activation throughout the dorsal fronto-parietal network for each condition, in line with many previous results. In order to investigate possible differences in the balance of neural activity within this network with greater sensitivity, a priori regions of interest (ROIs) were selected for analysis, centered on the frontal eye fields (FEF) and intraparietal sulcus (IPS) regions identified in previous studies. The results revealed a significant interaction between region, condition, and hemisphere. Specifically, in the left hemisphere, frontal areas were more active than parietal areas, but only during endogenous attention. Activity in the right hemisphere, in contrast, remained relatively consistent for these regions across conditions. Analysis of this activity over time indicates that this left-hemispheric regional imbalance is present within the FEF early, at 3-6.5 s post-stimulus presentation, whereas a regional imbalance in the exogenous condition is not evident until 6.5-8 s post-stimulus presentation. Overall, our results provide new evidence that although the dorsal fronto-parietal network is indeed associated with both types of attentional orienting, regions of the network are differentially engaged over time and across hemispheres depending on the type of attention. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. The effect of FeF2 on the magneto-optic response in FeF2/Fe/FeF2 sandwiches

    NASA Astrophysics Data System (ADS)

    Pištora, J.; Lesňák, M.; Lišková, E.; Višňovský, Š.; Harward, I.; Maslankiewicz, P.; Balin, K.; Celinski, Z.; Mistrík, J.; Yamaguchi, T.; Lopusnik, R.; Vlček, J.

    2010-04-01

    The room temperature optical constants n and k of MBE grown FeF2 films are reported. Because of poor chemical stability, FeF2 had to be coated with a protective Au layer. Reflection spectral ellipsometry in the photon energy range between 1.3 and 5.2 eV was performed on structures with a typical profile Au(0.5 nm)/FeF2(120 nm)/Au(30 nm)/Ag(20 nm)/Fe(0.6 nm) grown on GaAs(0 0 1) substrate. The spectra of n and k in FeF2 were subsequently employed in the design of FeF2/Fe/FeF2 sandwiches considered as magneto-optic (MO) sensors for weak microwave currents. Their MO response was evaluated using reflection MO (Kerr) spectroscopy at polar magnetization. The present results may be of interest in MO studies of magnetic nanostructures with Fe/FeF2/Fe, including MO magnetometry and MO magnetic domain imaging.

  19. Evidence of universal inverse-third power law for the shielding-induced fractional decrease in apex field enhancement factor at large spacings: a response via accurate Laplace-type calculations.

    PubMed

    de Assis, Thiago A; Dall'Agnol, Fernando F

    2018-05-16

    Numerical simulations are important when assessing the many characteristics of field emission related phenomena. In small simulation domains, the electrostatic effect from the boundaries is known to influence the calculated apex field enhancement factor (FEF) of the emitter, but no established dependence has been reported at present. In this work, we report the dependence of the lateral size, L, and the height, H, of the simulation domain on the apex-FEF of a single conducting ellipsoidal emitter. Firstly, we analyze the error, ε, in the calculation of the apex-FEF as a function of H and L. Importantly, our results show that the effects of H and L on ε are scale invariant, allowing one to predict ε for ratios L/h and H/h, where h is the height of the emitter. Next, we analyze the fractional change of the apex-FEF, δ, from a single emitter, [Formula: see text], and a pair, [Formula: see text]. We show that small relative errors in [Formula: see text] (i.e. [Formula: see text]), due to the finite domain size, are sufficient to alter the functional dependence [Formula: see text], where c is the distance from the emitters in the pair. We show that [Formula: see text] obeys a recently proposed power law decay (Forbes 2016 J. Appl. Phys. 120 054302), at sufficiently large distances in the limit of infinite domain size ([Formula: see text], say), which is not observed when using a long time established exponential decay (Bonard et al 2001 Adv. Mater. 13 184) or a more sophisticated fitting formula proposed recently by Harris et al (2015 AIP Adv. 5 087182). We show that the inverse-third power law functional dependence is respected for various systems like infinity arrays and small clusters of emitters with different shapes. Thus, [Formula: see text], with m  =  3, is suggested to be a universal signature of the charge-blunting effect in small clusters or arrays, at sufficient large distances between emitters with any shape. These results improve the physical understanding of the field electron emission theory to accurately characterize emitters in small clusters or arrays.

  20. Recurrent competition explains temporal effects of attention in MSTd

    PubMed Central

    Layton, Oliver W.; Browning, N. Andrew

    2012-01-01

    Navigation in a static environment along straight paths without eye movements produces radial optic flow fields. A singularity called the focus of expansion (FoE) specifies the direction of travel (heading) of the observer. Cells in primate dorsal medial superior temporal area (MSTd) respond to radial fields and are therefore thought to be heading-sensitive. Humans frequently shift their focus of attention while navigating, for example, depending on the favorable or threatening context of approaching independently moving objects. Recent neurophysiological studies show that the spatial tuning curves of primate MSTd neurons change based on the difference in visual angle between an attentional prime and the FoE. Moreover, the peak mean population activity in MSTd retreats linearly in time as the distance between the attentional prime and FoE increases. We present a dynamical neural circuit model that demonstrates the same linear temporal peak shift observed electrophysiologically. The model qualitatively matches the neuron tuning curves and population activation profiles. After model MT dynamically pools short-range motion, model MSTd incorporates recurrent competition between units tuned to different radial optic flow templates, and integrates attentional signals from model area frontal eye fields (FEF). In the model, population activity peaks occur when the recurrent competition is most active and uncertainty is greatest about the relative position of the FoE. The nature of attention, multiplicative or non-multiplicative, is largely irrelevant, so long as attention has a Gaussian-like profile. Using an appropriately tuned sigmoidal signal function to modulate recurrent feedback affords qualitative fits of deflections in the population activity that otherwise appear to be low-frequency noise. We predict that these deflections mark changes in the balance of attention between the priming and FoE locations. PMID:23060788

  1. 18F-EF5 PET-based Imageable Hypoxia Predicts Local Recurrence in Tumors Treated With Highly Conformal Radiation Therapy.

    PubMed

    Qian, Yushen; Von Eyben, Rie; Liu, Yufei; Chin, Frederick T; Miao, Zheng; Apte, Sandeep; Carter, Justin N; Binkley, Michael S; Pollom, Erqi L; Harris, Jeremy P; Prionas, Nicolas D; Kissel, Madelyn; Simmons, Amanda; Diehn, Maximilian; Shultz, David B; Brown, J Martin; Maxim, Peter G; Koong, Albert C; Graves, Edward E; Loo, Billy W

    2018-04-18

    Tumor hypoxia contributes to radiation resistance. A noninvasive assessment of tumor hypoxia would be valuable for prognostication and possibly selection for hypoxia-targeted therapies. 18 F-pentafluorinated etanidazole ( 18 F-EF5) is a nitroimidazole derivative that has demonstrated promise as a positron emission tomography (PET) hypoxia imaging agent in preclinical and clinical studies. However, correlation of imageable hypoxia by 18 F-EF5 PET with clinical outcomes after radiation therapy remains limited. Our study prospectively enrolled 28 patients undergoing radiation therapy for localized lung or other tumors to receive pretreatment 18 F-EF5 PET imaging. Depending on the level of 18 F-EF5 tumor uptake, patients underwent functional manipulation of tumor oxygenation with either carbogen breathing or oral dichloroacetate followed by repeated 18 F-EF5 PET. The hypoxic subvolume of tumor was defined as the proportion of tumor voxels exhibiting higher 18 F-EF5 uptake than the 95th percentile of 18 F-EF5 uptake in the blood pool. Tumors with a hypoxic subvolume ≥ 10% on baseline 18 F-EF5 PET imaging were classified as hypoxic by imaging. A Cox model was used to assess the correlation between imageable hypoxia and clinical outcomes after treatment. At baseline, imageable hypoxia was demonstrated in 43% of all patients (12 of 28), including 6 of 16 patients with early-stage non-small cell lung cancer treated with stereotactic ablative radiation therapy and 6 of 12 patients with other cancers. Carbogen breathing was significantly associated with decreased imageable hypoxia, while dichloroacetate did not result in a significant change under our protocol conditions. Tumors with imageable hypoxia had a higher incidence of local recurrence at 12 months (30%) than those without (0%) (P < .01). Noninvasive hypoxia imaging by 18 F-EF5 PET identified imageable hypoxia in about 40% of tumors in our study population. Local tumor recurrence after highly conformal radiation therapy was higher in tumors with imageable hypoxia. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. The Influence of Altering Push Force Effectiveness on Upper Extremity Demand during Wheelchair Propulsion

    PubMed Central

    Rankin, Jeffery W.; Kwarciak, Andrew M.; Richter, W. Mark; Neptune, Richard R.

    2010-01-01

    Manual wheelchair propulsion has been linked to a high incidence of overuse injury and pain in the upper extremity, which may be caused by the high load requirements and low mechanical efficiency of the task. Previous studies have suggested that poor mechanical efficiency may be due to a low effective handrim force (i.e. applied force that is not directed tangential to the handrim). As a result, studies attempting to reduce upper extremity demand have used various measures of force effectiveness (e.g. fraction effective force, FEF) as a guide for modifying propulsion technique, developing rehabilitation programs and configuring wheelchairs. However, the relationship between FEF and upper extremity demand is not well understood. The purpose of this study was to use forward dynamics simulations of wheelchair propulsion to determine the influence of FEF on upper extremity demand by quantifying individual muscle stress, work and handrim force contributions at different values of FEF. Simulations maximizing and minimizing FEF resulted in higher average muscle stresses (23% and 112%) and total muscle work (28% and 71%) compared to a nominal FEF simulation. The maximal FEF simulation also shifted muscle use from muscles crossing the elbow to those at the shoulder (e.g. rotator cuff muscles), placing greater demand on shoulder muscles during propulsion. The optimal FEF value appears to represent a balance between increasing push force effectiveness to increase mechanical efficiency and minimizing upper extremity demand. Thus, care should be taken in using force effectiveness as a metric to reduce upper extremity demand. PMID:20674921

  3. Variants in the interleukin 8 gene and the response to inhaled bronchodilators in cystic fibrosis.

    PubMed

    Furlan, Larissa Lazzarini; Ribeiro, José Dirceu; Bertuzzo, Carmen Sílvia; Salomão Junior, João Batista; Souza, Dorotéia Rossi Silva; Marson, Fernando Augusto Lima

    Interleukin 8 protein promotes inflammatory responses, even in airways. The presence of interleukin 8 gene variants causes altered inflammatory responses and possibly varied responses to inhaled bronchodilators. Thus, this study analyzed the interleukin 8 variants (rs4073, rs2227306, and rs2227307) and their association with the response to inhaled bronchodilators in cystic fibrosis patients. Analysis of interleukin 8 gene variants was performed by restriction fragment length polymorphism of polymerase chain reaction. The association between spirometry markers and the response to inhaled bronchodilators was evaluated by Mann-Whitney and Kruskal-Wallis tests. The analysis included all cystic fibrosis patients, and subsequently patients with two mutations in the cystic fibrosis transmembrane conductance regulator gene belonging to classes I to III. This study included 186 cystic fibrosis patients. There was no association of the rs2227307 variant with the response to inhaled bronchodilators. The rs2227306 variant was associated with FEF 50% in the dominant group and in the group with two identified mutations in the cystic fibrosis transmembrane conductance regulator gene. The rs4073 variant was associated with spirometry markers in four genetic models: co-dominant (FEF 25-75% and FEF 75% ), dominant (FEV 1 , FEF 50% , FEF 75% , and FEF 25-75% ), recessive (FEF 75% and FEF 25-75% ), and over-dominant (FEV 1 /FVC). This study highlighted the importance of the rs4073 variant of the interleukin 8 gene, regarding response to inhaled bronchodilators, and of the assessment of mutations in the cystic fibrosis transmembrane conductance regulator gene. Copyright © 2017 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  4. Application of radiosurgical techniques to produce a primate model of brain lesions

    PubMed Central

    Kunimatsu, Jun; Miyamoto, Naoki; Ishikawa, Masayori; Shirato, Hiroki; Tanaka, Masaki

    2015-01-01

    Behavioral analysis of subjects with discrete brain lesions provides important information about the mechanisms of various brain functions. However, it is generally difficult to experimentally produce discrete lesions in deep brain structures. Here we show that a radiosurgical technique, which is used as an alternative treatment for brain tumors and vascular malformations, is applicable to create non-invasive lesions in experimental animals for the research in systems neuroscience. We delivered highly focused radiation (130–150 Gy at ISO center) to the frontal eye field (FEF) of macaque monkeys using a clinical linear accelerator (LINAC). The effects of irradiation were assessed by analyzing oculomotor performance along with magnetic resonance (MR) images before and up to 8 months following irradiation. In parallel with tissue edema indicated by MR images, deficits in saccadic and smooth pursuit eye movements were observed during several days following irradiation. Although initial signs of oculomotor deficits disappeared within a month, damage to the tissue and impaired eye movements gradually developed during the course of the subsequent 6 months. Postmortem histological examinations showed necrosis and hemorrhages within a large area of the white matter and, to a lesser extent, in the adjacent gray matter, which was centered at the irradiated target. These results indicated that the LINAC system was useful for making brain lesions in experimental animals, while the suitable radiation parameters to generate more focused lesions need to be further explored. We propose the use of a radiosurgical technique for establishing animal models of brain lesions, and discuss the possible uses of this technique for functional neurosurgical treatments in humans. PMID:25964746

  5. High-pitched breath sounds indicate airflow limitation in asymptomatic asthmatic children.

    PubMed

    Habukawa, Chizu; Nagasaka, Yukio; Murakami, Katsumi; Takemura, Tsukasa

    2009-04-01

    Asthmatic children may have airway dysfunction even when asymptomatic, indicating that their long-term treatment is less than optimal. Although airway dysfunction can be identified on lung function testing, performing these tests can be difficult in infants. We studied whether breath sounds reflect subtle airway dysfunction in asthmatic children. The highest frequency of inspiratory breaths sounds (HFI) and the highest frequency of expiratory breath sounds (HFE) were measured in 131 asthmatic children while asymptomatic and with no wheezes for more than 2 weeks. No child was being treated with inhaled corticosteroids (ICS). Breath sounds were recorded and analysed by sound spectrography and compared with spirometric parameters. After initial evaluation, cases with more than step 2 (mild persistent) asthma were treated using inhaled fluticasone (100-200 microg/day) for 1 month, and then breath sound analysis and pulmonary function testing were repeated. On initial evaluation, HFI correlated with the percentage of predicted FEF(50) (%FEF(50)), (r = -0.45, P < 0.001), the percentage of predicted FEF(75) (%FEF(75)) (r = -0.456, P < 0.001), and FEV(1) as a percentage of FVC (FEV(1)/FVC (%)) (r = -0.32, P < 0.001). HFI did not correlate with the percentage of predicted PEF (%PEF). The 69 children with lower than normal %FEF(50) were then treated with ICS. The %FEF(50) and %FEF(75) improved after ICS treatment, and increases in %FEF(50) (P < 0.005) correlated with decreases in HFI (P < 0.001). Higher HFI in asymptomatic asthmatic children may indicate small airway obstruction. Additional ICS treatment may improve the pulmonary function indices representing small airway function with simultaneous HFI decreases in such patients.

  6. Persistent spatial information in the FEF during object-based short-term memory does not contribute to task performance.

    PubMed

    Clark, Kelsey L; Noudoost, Behrad; Moore, Tirin

    2014-06-01

    We previously reported the existence of a persistent spatial signal in the FEF during object-based STM. This persistent activity reflected the location at which the sample appeared, irrespective of the location of upcoming targets. We hypothesized that such a spatial signal could be used to maintain or enhance object-selective memory activity elsewhere in cortex, analogous to the role of a spatial signal during attention. Here, we inactivated a portion of the FEF with GABAa agonist muscimol to test whether the observed activity contributes to object memory performance. We found that, although RTs were slowed for saccades into the inactivated portion of retinotopic space, performance for samples appearing in that region was unimpaired. This contrasts with the devastating effects of the same FEF inactivation on purely spatial working memory, as assessed with the memory-guided saccade task. Thus, in a task in which a significant fraction of FEF neurons displayed persistent, sample location-based activity, disrupting this activity had no impact on task performance.

  7. Transcranial ultrasonic stimulation modulates single-neuron discharge in macaques performing an antisaccade task.

    PubMed

    Wattiez, Nicolas; Constans, Charlotte; Deffieux, Thomas; Daye, Pierre M; Tanter, Mickael; Aubry, Jean-François; Pouget, Pierre

    Low intensity transcranial ultrasonic stimulation (TUS) has been demonstrated to non-invasively and transiently stimulate the nervous system. Although US neuromodulation has appeared robust in rodent studies, the effects of US in large mammals and humans have been modest at best. In addition, there is a lack of direct recordings from the stimulated neurons in response to US. Our study investigates the magnitude of the US effects on neuronal discharge in awake behaving monkeys and thus fills the void on both fronts. In this study, we demonstrate the feasibility of recording action potentials in the supplementary eye field (SEF) as TUS is applied simultaneously to the frontal eye field (FEF) in macaques performing an antisaccade task. We show that compared to a control stimulation in the visual cortex, SEF activity is significantly modulated shortly after TUS onset. Among all cell types 40% of neurons significantly changed their activity after TUS. Half of the neurons showed a transient increase of activity induced by TUS. Our study demonstrates that the neuromodulatory effects of non-invasive focused ultrasound can be assessed in real time in awake behaving monkeys by recording discharge activity from a brain region reciprocally connected with the stimulated region. The study opens the door for further parametric studies for fine-tuning the ultrasonic parameters. The ultrasonic effect could indeed be quantified based on the direct measurement of the intensity of the modulation induced on a single neuron in a freely performing animal. The technique should be readily reproducible in other primate laboratories studying brain function, both for exploratory and therapeutic purposes and to facilitate the development of future clinical TUS devices. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Local Immediate versus Long-Range Delayed Changes in Functional Connectivity Following rTMS on the Visual Attention Network.

    PubMed

    Battelli, Lorella; Grossman, Emily D; Plow, Ela B

    The interhemispheric competition hypothesis attributes the distribution of selective attention to a balance of mutual inhibition between homotopic, interhemispheric connections in parietal cortex (Kinsbourne 1977; Battelli et al., 2009). In support of this hypothesis, repetitive inhibitory TMS over right parietal cortex in healthy individuals rapidly induces interhemispheric imbalance in cortical activity that spreads beyond the site of stimulation (Plow et al., 2014). Behaviorally, the impacts of inhibitory rTMS may be long delayed from the onset of stimulation, as much as 30 minutes (Agosta et al., 2014; Hubl et al., 2008). In this study, we examine the temporal dynamics of inhibitory rTMS on cortical network integrity that supports sustained visual attention. Healthy individuals received 15 min of 1 Hz offline, inhibitory rTMS (or sham) over left parietal cortex, and then immediately engaged in a bilateral visual tracking task while we recorded brain activity with fMRI. We computed functional connectivity (FC) between three nodes of the attention network engaged by visual tracking: the intraparietal sulcus (IPS), frontal eye fields (FEF) and human MT+ (hMT+). FC immediately and significantly decreased between the stimulation site (left IPS) and all other regions, then recovered to normal levels within 30 minutes. rTMS increased FC between left and right FEF at approximately 36 min following stimulation, and between sites in the unstimulated hemisphere approximately 48 min after stimulation. These findings demonstrate large-scale changes in cortical organization following inhibitory rTMS. The immediate impact of rTMS on connectivity to the stimulation site dovetails with the putative role of interhemispheric balance for bilateral visual sustained attention. The delayed, compensatory increases in functional connectivity have implications for models of dynamic reorganization in networks supporting spatial and nonspatial selective attention, and compensatory mechanisms within these networks that may be stabilized in chronic stroke. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Lung volume and expiratory flow rates from pre- to post-puberty.

    PubMed

    Smith, Joshua R; Emerson, Sam R; Kurti, Stephanie P; Gandhi, Kirti; Harms, Craig A

    2015-08-01

    The purpose was to determine if the airways and lungs grow disproportionately from pre- to post-puberty in boys and girls. We hypothesized that the airways grow at a slower rate than lung volume (i.e. dysanapsis growth) during puberty and boys would exhibit more dysanaptic growth compared to girls. Twenty-one pre-pubescent children [11 boys (pre 10.1 ± 0.5 years, post 15.3 ± 0.5 years); 10 girls (pre 9.4 ± 1.0 years, post 14.1 ± 1.0 years)] performed pulmonary function tests (PFTs) ~5 years ago from an original cohort of 40 children. These 21 children performed PFTs, which included forced vital capacity (FVC) and forced expiratory flow at 50 % FVC (FEF50). Static pressure at 50 % of FVC [Pst(L)50 %] was estimated based on age. Dysanapsis ratio (DR) was calculated [FEF50 × FVC(-1) × Pst(L) 50 % (-1) ]. Maturation status was determined via Tanner stages. Stage of maturation was not different (p > 0.05) between boys and girls (4.2 ± 0.6 stage vs. 3.7 ± 0.7 stage, respectively). FVC and FEF50 increased (p < 0.05), DR significantly decreased, and FEF50/FVC was similar (p > 0.05) from pre- to post-puberty. FEF50 and FVC significantly increased and DR decreased (p < 0.05) post-puberty for both sexes. Post-puberty, boys had a significantly larger FVC, but FEF50, DR, and FEF50/FVC were not different (p > 0.05) compared to girls. These data suggest that dysanaptic growth occurs during puberty and that it is not different between boys and girls.

  10. Probiotics and Time to Achieve Full Enteral Feeding in Human Milk-Fed and Formula-Fed Preterm Infants: Systematic Review and Meta-Analysis

    PubMed Central

    Aceti, Arianna; Gori, Davide; Barone, Giovanni; Callegari, Maria Luisa; Fantini, Maria Pia; Indrio, Flavia; Maggio, Luca; Meneghin, Fabio; Morelli, Lorenzo; Zuccotti, Gianvincenzo; Corvaglia, Luigi

    2016-01-01

    Probiotics have been linked to a reduction in the incidence of necrotizing enterocolitis and late-onset sepsis in preterm infants. Recently, probiotics have also proved to reduce time to achieve full enteral feeding (FEF). However, the relationship between FEF achievement and type of feeding in infants treated with probiotics has not been explored yet. The aim of this systematic review and meta-analysis was to evaluate the effect of probiotics in reducing time to achieve FEF in preterm infants, according to type of feeding (exclusive human milk (HM) vs. formula). Randomized-controlled trials involving preterm infants receiving probiotics, and reporting on time to reach FEF were included in the systematic review. Trials reporting on outcome according to type of feeding (exclusive HM vs. formula) were included in the meta-analysis. Fixed-effect or random-effects models were used as appropriate. Results were expressed as mean difference (MD) with 95% confidence interval (CI). Twenty-five studies were included in the systematic review. In the five studies recruiting exclusively HM-fed preterm infants, those treated with probiotics reached FEF approximately 3 days before controls (MD −3.15 days (95% CI −5.25/−1.05), p = 0.003). None of the two studies reporting on exclusively formula-fed infants showed any difference between infants receiving probiotics and controls in terms of FEF achievement. The limited number of included studies did not allow testing for other subgroup differences between HM and formula-fed infants. However, if confirmed in further studies, the 3-days reduction in time to achieve FEF in exclusively HM-fed preterm infants might have significant implications for their clinical management. PMID:27483319

  11. Probiotics and Time to Achieve Full Enteral Feeding in Human Milk-Fed and Formula-Fed Preterm Infants: Systematic Review and Meta-Analysis.

    PubMed

    Aceti, Arianna; Gori, Davide; Barone, Giovanni; Callegari, Maria Luisa; Fantini, Maria Pia; Indrio, Flavia; Maggio, Luca; Meneghin, Fabio; Morelli, Lorenzo; Zuccotti, Gianvincenzo; Corvaglia, Luigi

    2016-07-30

    Probiotics have been linked to a reduction in the incidence of necrotizing enterocolitis and late-onset sepsis in preterm infants. Recently, probiotics have also proved to reduce time to achieve full enteral feeding (FEF). However, the relationship between FEF achievement and type of feeding in infants treated with probiotics has not been explored yet. The aim of this systematic review and meta-analysis was to evaluate the effect of probiotics in reducing time to achieve FEF in preterm infants, according to type of feeding (exclusive human milk (HM) vs. formula). Randomized-controlled trials involving preterm infants receiving probiotics, and reporting on time to reach FEF were included in the systematic review. Trials reporting on outcome according to type of feeding (exclusive HM vs. formula) were included in the meta-analysis. Fixed-effect or random-effects models were used as appropriate. Results were expressed as mean difference (MD) with 95% confidence interval (CI). Twenty-five studies were included in the systematic review. In the five studies recruiting exclusively HM-fed preterm infants, those treated with probiotics reached FEF approximately 3 days before controls (MD -3.15 days (95% CI -5.25/-1.05), p = 0.003). None of the two studies reporting on exclusively formula-fed infants showed any difference between infants receiving probiotics and controls in terms of FEF achievement. The limited number of included studies did not allow testing for other subgroup differences between HM and formula-fed infants. However, if confirmed in further studies, the 3-days reduction in time to achieve FEF in exclusively HM-fed preterm infants might have significant implications for their clinical management.

  12. Building an Electronic Bridge via Ag Decoration To Enhance Kinetics of Iron Fluoride Cathode in Lithium-Ion Batteries.

    PubMed

    Li, Yu; Zhou, Xingzhen; Bai, Ying; Chen, Guanghai; Wang, Zhaohua; Li, Hui; Wu, Feng; Wu, Chuan

    2017-06-14

    As a typical multielectron cathode material for lithium-ion batteries, iron fluoride (FeF 3 ) and its analogues suffer from poor electronic conductivity and low actual specific capacity. Herein, we introduce Ag nanoparticles by silver mirror reaction into the FeF 3 ·0.33H 2 O cathode to build the electronic bridge between the solid (active materials) and liquid (electrolyte) interface. The crystal structures of as-prepared samples are characterized by X-ray diffraction and Rietveld refinement. Moreover, the density of states of FeF 3 ·0.33H 2 O and FeF 3 ·0.33H 2 O/Ag (Ag-decorated FeF 3 ·0.33H 2 O) samples are calculated using the first principle density functional theory. The FeF 3 ·0.33H 2 O/Ag cathodes exhibit significant enhancements on the electrochemical performance in terms of the cycle performance and rate capability, especially for the Ag-decorated amount of 5%. It achieves an initial capacity of 168.2 mA h g -1 and retains a discharge capacity of 128.4 mA h g -1 after 50 cycles in the voltage range of 2.0-4.5 V. It demonstrates that Ag decoration can reduce the band gap, improve electronic conductivity, and elevate intercalation/deintercalation kinetics.

  13. Molecular beam epitaxy growth of SmFeAs(O,F) films with Tc = 55 K using the new fluorine source FeF3

    NASA Astrophysics Data System (ADS)

    Sakoda, Masahito; Ishii, Akihiro; Takinaka, Kenji; Naito, Michio

    2017-07-01

    REFeAs(O,F) (RE: rare-earth element) has the highest-Tc (˜58 K) among the iron-based superconductors, but a thin-film growth of REFeAs(O,F) is difficult. This is because it is not only a complex compound consisting of five elements but also requires doping of highly reactive fluorine to achieve superconductivity. We have reported in our previous article that fluorine can be supplied to a film by subliming solid-state fluorides such as FeF2 or SmF3. In this article, we report on the growth of SmFeAs(O,F) using FeF3 as an alternative fluorine source. FeF3 is solid at ambient temperatures and decomposes at temperatures as low as 100-200 °C, and releases fluorine-containing gas during the thermal decomposition. With this alternative fluorine source, we have grown SmFeAs(O,F) films with Tc as high as 55 K. This achievement demonstrates that FeF3 has potential as a fluorine source that can be employed ubiquitously for a thin-film growth of any fluorine containing compounds. One problem specific to FeF3 is that the compound is highly hydroscopic and contains a substantial amount of water even in its anhydrous form. In this article, we describe how to overcome this specific problem.

  14. Are flexion extension films necessary for cervical spine clearance in patients with neck pain after negative cervical CT scan?

    PubMed

    Tran, Baotram; Saxe, Jonathan M; Ekeh, Akpofure Peter

    2013-09-01

    There are variations in cervical spine (CS) clearance protocols in neurologically intact blunt trauma patients with negative radiological imaging but persistent neck pain. Current guidelines from the current Eastern Association for the Surgery of Trauma include options of maintaining the cervical collar or obtaining either magnetic resonance imaging (MRI) or flexion-extension films (FEF). We evaluated the utility of FEF in the current era of routine computerized tomography (CT) for imaging the CS in trauma. All neurologically intact, awake, nonintoxicated patients who underwent FEF for persistent neck pain after negative CT scan of the CS at our level I trauma center over a 13-mo period were identified. Their charts were reviewed and demographic data obtained. There were 354 patients (58.5% male) with negative cervical CS CT scans who had FEF for residual neck pain. Incidental degenerative changes were seen in 37%--which did not affect their acute management. FEF were positive for possible ligamentous injury in 5 patients (1.4%). Two of these patients had negative magnetic resonance images and the other three had collars removed within 3 wk as the findings were ultimately determined to be degenerative. In the current era, where cervical CT has universally supplanted initial plain films, FEF appear to be of little value in the evaluation of persistent neck pain. Their use should be excluded from cervical spine clearance protocols in neurologically intact, awake patients. Copyright © 2013 Elsevier Inc. All rights reserved.

  15. High-Temperature Electrochemical Performance of FeF3/C Nanocomposite as a Cathode Material for Lithium-Ion Batteries

    NASA Astrophysics Data System (ADS)

    Tang, Mengyun; Zhang, Zhengfu; Wang, Zi; Liu, Jingfeng; Yan, Hongge; Peng, Jinhui

    2018-02-01

    Iron trifluoride has been studied as a cathode material due to its cost-effectiveness, low toxicity, and high theoretical capacities of 712 mA h g-1. However, FeF3 has serious shortcomings of poor electronic conductivity and a slow diffusion rate of lithium ions, leading to a lower reversible specific capacity. In this work, FeF3/C nanocomposite has been synthesized successfully via a high-energy ball-milling method, and acetylene black is used as the conductive agent to improve the conductivity of FeF3. The FeF3/C nanocomposite shows a high initial discharge capacity of 346.25 and 161.58 mA h g-1 after 40th cycle at 50 mA g-1. It exhibits good cycle performance and rate performance. The high-temperature discharge capacities decreased with increase in the temperature. The initial high-temperature discharge capacities are found to be 254.17, 300.01, 281.25 and 125.16, and 216.875, 156, 141.67, 150, and 64.98 mA h g-1 at 20th cycles at the 40, 50, 60, and 70 °C, respectively.

  16. Lung function gain in preterm infants with and without bronchopulmonary dysplasia.

    PubMed

    Sanchez-Solis, Manuel; Perez-Fernandez, Virginia; Bosch-Gimenez, Vicente; Quesada, Juan J; Garcia-Marcos, Luis

    2016-09-01

    The aim of our study was to determine whether the development of lung function, during the first 2 years of life, is different in preterm infants who suffered or did not suffer from Bronchopulmonary dysplasia (BPD). We also assessed the role of nutritional status and growth in that development. Lung function tests were performed in 71 preterm infants at two time points: 6 months of corrected age and 1 year after. FVC, FEV0.5, FEF75 , and FEF25-75 were obtained from maximal expiratory volume curves by means of the raised volume rapid thoraco-abdominal compression technique. When comparing lung function measurements, we found that FVC (P = 0.033) FEV0.5 (P = 0.044), FEF75 (P = 0.014), and FEF25-75 (P = 0.036) were significantly lower in BPD infants. We did not find any catch-up of lung function during the study time, in neither the whole group of children nor within the BPD or non-BPD groups. The increase in lung function was directly proportional to the increase in weight and length. The multivariate analysis showed that the increase in z-score of FVC (P = 0.043), FEV0.5 (P = 0.015), and FEF75 (P = 0.042), was related with the height velocity during the study period. Infants who suffered from BPD have lower lung function (FVC, FEV0.5 , FEF75 , and FEF25-75 ), than those non-BPD, at two different time points 1 year apart. During the study period, there was no lung function catch-up in either BPD or non-BPD infants. The increase in length is closely associated to the increase in lung function. Pediatr Pulmonol. 2016; 51:936-942. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  17. Nasal versus oronasal raised volume forced expirations in infants – A real physiologic challenge

    PubMed Central

    Morris, Mohy G.

    2012-01-01

    Summary Raised volume rapid thoracoabdominal compression (RTC) generates forced expiration (FE) in infants typically from an airway opening pressure of 30 cm H2O (V30). We hypothesized that the higher nasal than pulmonary airway resistance limits forced expiratory flows (FEF%) during (nasal) FEn, which an opened mouth, (oronasal) FEo, would resolve. Measurements were performed during a brief post-hyperventilation apnea on twelve healthy infants aged 6.9–104 weeks. In two infants, forced expiratory (FEFV) flow volume (FV) curves were generated using a facemask that covered the nose and a closed mouth, then again with a larger mask with the mouth opened. In other infants (n=10), the mouth closed spontaneously during FE. Oronasal passive expiration from V30 generated either the inspiratory capacity (IC) or by activating RTC before end-expiration, the slow vital capacity (jSVC). Peak flow (PF), FEF25, FEF50, FEF25–75, FEV0.4 and FEV0.5 were lower via FEn than FEo (p<0.05), but the ratio of expired volume at PF and forced vital capacity (FVC) as percent was higher (p<0.05). FEF75, FEF85, FEF90, FVC as well as the applied jacket pressures were not different (p>0.05). FEFV curves generated via FEo exhibited higher PF than FV curves of IC (p< 0.05); PF of those produced via FEn were not different from FV curves of IC (p> 0.05) but lower than those of jSVC (p< 0.05). In conclusion, the higher nasal than pulmonary airways resistance unequivocally affects the FEFV curves by consistently reducing PF and decreases mid-expiratory flows. A monitored slightly opened mouth and a gentle anterior jaw thrust are physiologically integral for raised volume RTC in order to maximize the oral and minimize nasal airways contribution to FE so that flow limitation would be in the pulmonary not nasal airways. PMID:22328241

  18. Effects of ambient air pollution from municipal solid waste landfill on children's non-specific immunity and respiratory health.

    PubMed

    Yu, Yunjiang; Yu, Ziling; Sun, Peng; Lin, Bigui; Li, Liangzhong; Wang, Zhengdong; Ma, Ruixue; Xiang, Mingdeng; Li, Hui; Guo, Shu

    2018-05-01

    This cross-sectional study investigated the association between air pollutant (AP) and respiratory health of 951 children residing near a municipal solid waste (MSW) landfill in Northern China. Results showed that students in non-exposure areas had significantly higher levels of lysozyme, secretory immunoglobulin A (SIgA), and better lung capacity than students in exposure areas (p < .05). Multiple regression model analysis indicated that lysozyme levels exhibited a consistent negative association with methane (CH 4 : β = -76.3, 95% CI -105 to -47.7) and sulfuretted hydrogen (H 2 S: β = -11.7, 95% CI -20.2 to -3.19). In addition, SIgA levels were negatively associated with H 2 S (β = -68.9, 95% CI -97.9 to -39.9) and ammonia (NH 3 : β = -30.3, 95% CI -51.7 to -8.96). Among all AP, H 2 S and sulfur dioxide (SO 2 ) were the most robustly related with reduced lung function. H 2 S exposure was negatively associated with six lung function indices, 1-s forced expiratory volume (FEV1%), mean forced expiratory flow between 25% and 75% (MMF), maximum voluntary ventilation (MVV), and forced expiratory flow at 25%, 50%, and 75% of the pulmonary volume (FEF25, FEF50, FEF75); and SO 2 was negatively associated with FEV1%, MVV, FEF25, FEF50 and FEF75. Our results suggested that AP exposure was negatively associated with more lung function parameters in boys than in girls. In conclusion, our findings suggested that children living adjacent to landfill sites were more likely to have deficient non-specific immunity and impaired lung function. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. High-capacity lithium-ion battery conversion cathodes based on iron fluoride nanowires and insights into the conversion mechanism.

    PubMed

    Li, Linsen; Meng, Fei; Jin, Song

    2012-11-14

    The increasing demands from large-scale energy applications call for the development of lithium-ion battery (LIB) electrode materials with high energy density. Earth abundant conversion cathode material iron trifluoride (FeF(3)) has a high theoretical capacity (712 mAh g(-1)) and the potential to double the energy density of the current cathode material based on lithium cobalt oxide. Such promise has not been fulfilled due to the nonoptimal material properties and poor kinetics of the electrochemical conversion reactions. Here, we report for the first time a high-capacity LIB cathode that is based on networks of FeF(3) nanowires (NWs) made via an inexpensive and scalable synthesis. The FeF(3) NW cathode yielded a discharge capacity as high as 543 mAh g(-1) at the first cycle and retained a capacity of 223 mAh g(-1) after 50 cycles at room temperature under the current of 50 mA g(-1). Moreover, high-resolution transmission electron microscopy revealed the existence of continuous networks of Fe in the lithiated FeF(3) NWs after discharging, which is likely an important factor for the observed improved electrochemical performance. The loss of active material (FeF(3)) caused by the increasingly ineffective reconversion process during charging was found to be a major factor responsible for the capacity loss upon cycling. With the advantages of low cost, large quantity, and ease of processing, these FeF(3) NWs are not only promising battery cathode materials but also provide a convenient platform for fundamental studies and further improving conversion cathodes in general.

  20. Evidence of Allergic Reactions and Cardiopulmonary Impairments among Traders Operating from Foodstuff Warehouses

    PubMed Central

    Egbosionu, Viola; Ibeneme, Georgian; Ezuma, Amarachi; Ettu, Theresa; Nwankwo, Joseph; Limaye, Dnyanesh; Nna, Emmanuel

    2016-01-01

    Background. Foodstuff traders operating from warehouses (FTFW) are potentially exposed to dangerous rodenticides/pesticides that may have adverse effects on cardiopulmonary function. Methods. Fifty consenting male foodstuff traders, comprising 15 traders (21–63 years) operating outside warehouses and 35 FTFW (20–64 years), were randomly recruited at Ogbete Market, Enugu, in a cross-sectional observational study of spirometric and electrocardiographic parameters. Seventeen FTFW (21–57 years) participated in focus group discussions. Qualitative and quantitative data were analysed thematically and with independent t-test and Pearson correlation coefficient at p < 0.05, respectively. Results. Most FTFW experienced respiratory symptoms, especially dry cough (97.1%) and wheezing (31.4%) with significant reductions in forced vital capacity (FVC) (t = −2.654; p = 0.011), forced expiratory volume in one second (FEV1) (t = −2.240; p = 0.030), maximum expiratory flow rate (FEF200–1200) (t = −1.148; p = −0.047), and forced end-expiratory flow (FEF75–85) (t = −1.11; p = 0.007). The maximum mid-expiratory flow (FEF25–75) was marginally decreased (p > 0.05) with a significantly prolonged (p < 0.05) QTc interval. Conclusion. Allergic response was evident in the FTFW. Significant decrease in FVC may negatively impact lung flow rates and explains the marginal decrease in FEF25–75, which implies a relative limitation in airflow of peripheral/distal airways and elastic recoil of the lungs. This is consistent with obstructive pulmonary disease; a significant decrease in FEF75–85/FEV1 supports this conclusion. Significant decrease in FEF200–1200 indicates abnormalities in the large airways/larynx just as significantly prolonged ventricular repolarization suggests cardiac arrhythmias. PMID:28116288

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Archer, V.E.; Fullmer, C.D.; Castle, C.H.

    Although acute effects from exposure to SO/sub 2/ have frequently been observed at low levels in acute exposure experimental studies, it was not known whether or not such effects occur among workers chronically exposed at ranges of 0.3 to 4 ppM of SO/sub 2/. Measurements of FVC, FEV/sub 1/, FEF/sub 50/, FEF/sub 75/ and FEF/sub 50-75/, and closing volume were made before and after the workshift for copper smelter workers and controls. Sputum samples for cytological examination were collected. Mean FEV/sub 1/ and FVC were significantly decreased during a day's work in the smelter. Significantly more smelter workers had amore » decrease in FEV/sub 1/ and FEF/sub 50/ during the day than did controls. More of the smelter workers felt chest tightness. No change in closing volumes was seen. Smelter workers tended to have a higher percentage of sputum samples with moderate and marked atypia than did controls but the difference was not statistically significant.« less

  2. Effect of isoprenaline and cigarette smoking on airways.

    PubMed

    Mahajan, K K; Reghunandan, V; Maini, B K; Mahajan, S K

    1983-01-01

    After two hours of abstinence from smoking pulmonary functions were assessed in twenty-seven asymptomatic male smokers by spirometry and Wright Peak Flow Meter, recording FVC, FEV1, FEV1%, FEF25-75%, and FEF75-85% of FVC, MVV and PEFR. These tests were repeated immediately after smoking and again after one hr. Only PEFR decreased significantly (P less than 0.01) and returned to nearly basal level after one hr. Sixteen of these smokers were subjected to further study. Isoprenaline inhalation in these smokers caused a significant improvement in most of the flow rates. Smoking of cigarettes at this stage decreased flow rates. After one hr the effect of smoking was over and most of the parameters were between basal and post-isoprenaline levels. Smoking affects the flow rates more than other parameters. An improvement in FEV1, FEV1%, FEF25-75% and FEF75-85% of FVC, after bronchodilator inhalation suggests the presence of some reversible bronchoconstriction specially of smaller airways basically present in chronic smokers.

  3. Long-term exposure to diesel engine exhaust induced lung function decline in a cross sectional study

    PubMed Central

    ZHANG, Li Ping; ZHANG, Xiao; DUAN, Hua Wei; MENG, Tao; NIU, Yong; HUANG, Chuan Feng; GAO, Wei Min; YU, Shan Fa; ZHENG, Yu Xin

    2016-01-01

    To clarify the effects of lung function following exposure to diesel engine exhaust (DEE), we recruited 137 diesel engine testing workers exposed to DEE and 127 non-DEE-exposed workers as study subjects. We performed lung function tests and measured cytokinesis-block micronucleus (CBMN) cytome index and levels of urinary polycyclic aromatic hydrocarbons (PAHs) metabolites. There was a significant decrease of forced expiratory volume in 1 second (FEV1), ratio of forced expiratory volume in 1 second to forced vital capacity (FEV1/ FVC), maximal mid expiratory flow curve (MMF), forced expiratory flow at 50% of FVC (FEF50%), and forced expiratory flow at 75% of FVC (FEF75%) in the DEE-exposed workers than non-DEE-exposed workers (all p<0.05). Among all study subjects, the decreases of FEF75% were associated with the increasing levels of PAHs metabolites (p<0.05), and there were negative correlations between FEV1, FEV1/FVC, MMF, FEF50%, and FEF75% with CBMN cytome index (all p<0.05). Our results show that long-term exposure to DEE can induce lung function decline which shows mainly obstructive changes and influence of small airways function. The decreased lung function is associated with internal dosage of DEE exposure, and accompany with the increasing CBMN cytome index. PMID:27334424

  4. The mechanical behaviour of NBR/FEF under compressive cyclic stress strain

    NASA Astrophysics Data System (ADS)

    Mahmoud, W. E.; El-Eraki, M. H. I.; El-Lawindy, A. M. Y.; Hassan, H. H.

    2006-06-01

    Acrylonitrile butadiene rubber compounds filled with different concentrations of fast extrusion furnace (FEF) carbon black were experimentally investigated. The stress-strain curves of the composites were studied, which suggest good filler-matrix adhesion. The large reinforcement effect of the filler followed the Guth model for non-spherical particles. The effect of FEF carbon black on the cyclic fatigue and hysteresis was also examined. The loading and unloading stress-strain relationships for any cycle were described by applying Ogden's model for rubber samples. The dissipation energy that indicates the vibration damping capacity for all samples was determined. A simple model was proposed, to investigate the relation between maximum stress and the number of cyclic fatigue.

  5. FeF(3) catalyzed cascade C-C and C-N bond formation: synthesis of differentially substituted triheterocyclic benzothiazole functionalities under solvent-free condition.

    PubMed

    Atar, Amol B; Jeong, Yeon Tae

    2014-05-01

    A series of diverse polyfunctionalized triheterocyclic benzothiazoles were easily prepared in excellent yields via the Biginelli reaction of 2-aminobenzothiazole with substituted benzaldehydes and α-methylene ketones using FeF(3) as an expeditious catalyst under solvent-free conditions. The protocol provides a practical and straightforward approach toward highly functionalized triheterocyclic benzothiazole derivatives in excellent yields. The reaction was conveniently promoted by FeF(3) and the catalyst could be recovered easily after the reaction and reused without any loss of its catalytic activity. The advantageous features of this methodology are high atom economy, operational simplicity, shorter reaction time, convergence, and facile automation.

  6. Recovery of central Appalachian forested watershed

    Treesearch

    Mary Beth Adams; James N. Kochendenfer [sic

    2014-01-01

    The Fernow Experimental Forest (FEF) was established to conduct research in forest and watershed management in the central Appalachians. The 1868-ha FEF, located south of Parsons, West Virginia, is administered by the Northern Research Station of the USDA Forest Service and provides a valuable point of comparison with the Coweeta Hydrologic Laboratory (CHL), located in...

  7. Tracer kinetics of forearm endothelial function: comparison of an empirical method and a quantitative modeling technique.

    PubMed

    Zhao, Xueli; Arsenault, Andre; Lavoie, Kim L; Meloche, Bernard; Bacon, Simon L

    2007-01-01

    Forearm Endothelial Function (FEF) is a marker that has been shown to discriminate patients with cardiovascular disease (CVD). FEF has been assessed using several parameters: the Rate of Uptake Ratio (RUR), EWUR (Elbow-to-Wrist Uptake Ratio) and EWRUR (Elbow-to-Wrist Relative Uptake Ratio). However, the modeling functions of FEF require more robust models. The present study was designed to compare an empirical method with quantitative modeling techniques to better estimate the physiological parameters and understand the complex dynamic processes. The fitted time activity curves of the forearms, estimating blood and muscle components, were assessed using both an empirical method and a two-compartment model. Although correlational analyses suggested a good correlation between the methods for RUR (r=.90) and EWUR (r=.79), but not EWRUR (r=.34), Altman-Bland plots found poor agreement between the methods for all 3 parameters. These results indicate that there is a large discrepancy between the empirical and computational method for FEF. Further work is needed to establish the physiological and mathematical validity of the 2 modeling methods.

  8. Spirometric Reference Equations for Elderly Chinese in Jinan Aged 60–84 Years

    PubMed Central

    Tian, Xin-Yu; Liu, Chun-Hong; Wang, De-Xiang; Ji, Xiu-Li; Shi, Hui; Zheng, Chun-Yan; Xie, Meng-Shuang; Xiao, Wei

    2018-01-01

    Background: The interpretation of spirometry varies on different reference values. Older people are usually underrepresented in published predictive values. This study aimed at developing spirometric reference equations for elderly Chinese in Jinan aged 60–84 years and to compare them to previous equations. Methods: The project covered all of Jinan city, and the recruitment period lasted 9 months from January 1, 2017 to September 30, 2017, 434 healthy people aged 60–84 years who had never smoked (226 females and 208 males) were recruited to undergo spirometry. Vital capacity (VC), forced VC (FVC), forced expiratory volume in 1 s (FEV1), FEV1/FVC, FEV1/VC, FEV6, peak expiratory flow, and forced expiratory flow at 25%, 50%, 75%, and 25–75% of FVC exhaled (FEF25%, FEF50%, FEF75%, and FEF25–75%) were analyzed. Reference equations for mean and the lower limit of normal (LLN) were derived using the lambda-mu-sigma method. Comparisons between new and previous equations were performed by paired t-test. Results: New reference equations were developed from the sample. The LLN of FEV1/FVC, FEF25–75% computed using the 2012-Global Lung Function Initiative (GLI) and 2006-Hong Kong equations were both lower than the new equations. The biggest degree of difference for FEV1/FVC was 19% (70.46% vs. 59.29%, t = 33.954, P < 0.01) and for maximal midexpiratory flow (MMEF, equals to FEF25–75%) was 22% (0.82 vs. 0.67, t = 21.303, P < 0.01). The 1990-North China and 2009-North China equations predicted higher mean values of FEV1/FVC and FEF25–75% than the present model. The biggest degrees of difference were −4% (78.31% vs. 81.27%, t = −85.359, P < 0.01) and −60% (2.11 vs. 4.68, t = −170.287, P < 0.01), respectively. Conclusions: The newly developed spirometric reference equations are applicable to elderly Chinese in Jinan. The 2012-GLI and 2006-Hong Kong equations may lead to missed diagnoses of obstructive ventilatory defects and the small airway dysfunction, while traditional linear equations for all ages may lead to overdiagnosis. PMID:29553052

  9. Prediction processes during multiple object tracking (MOT): involvement of dorsal and ventral premotor cortices

    PubMed Central

    Atmaca, Silke; Stadler, Waltraud; Keitel, Anne; Ott, Derek V M; Lepsien, Jöran; Prinz, Wolfgang

    2013-01-01

    Background The multiple object tracking (MOT) paradigm is a cognitive task that requires parallel tracking of several identical, moving objects following nongoal-directed, arbitrary motion trajectories. Aims The current study aimed to investigate the employment of prediction processes during MOT. As an indicator for the involvement of prediction processes, we targeted the human premotor cortex (PM). The PM has been repeatedly implicated to serve the internal modeling of future actions and action effects, as well as purely perceptual events, by means of predictive feedforward functions. Materials and methods Using functional magnetic resonance imaging (fMRI), BOLD activations recorded during MOT were contrasted with those recorded during the execution of a cognitive control task that used an identical stimulus display and demanded similar attentional load. A particular effort was made to identify and exclude previously found activation in the PM-adjacent frontal eye fields (FEF). Results We replicated prior results, revealing occipitotemporal, parietal, and frontal areas to be engaged in MOT. Discussion The activation in frontal areas is interpreted to originate from dorsal and ventral premotor cortices. The results are discussed in light of our assumption that MOT engages prediction processes. Conclusion We propose that our results provide first clues that MOT does not only involve visuospatial perception and attention processes, but prediction processes as well. PMID:24363971

  10. Cortical functional anatomy of voluntary saccades in Parkinson disease.

    PubMed

    Rieger, Jochem W; Kim, Aleander; Argyelan, Miklos; Farber, Mark; Glazman, Sofya; Liebeskind, Marc; Meyer, Thomas; Bodis-Wollner, Ivan

    2008-10-01

    In Parkinson Disease (PD) several aspects of saccades are affected. The saccade-generating brainstem neurons are spared, however, the signals they receive may be flawed. In particular voluntary saccades suffer, but the functional anatomy of the impairment of saccade-related cortical control is unknown. We measured blood-oxygenation-level-dependent (BOLD) activation with functional Magnetic Resonance Imaging (fMRI) while healthy participants and patients with PD performed horizontal voluntary saccades between peripheral visual targets or fixated centrally. We compared saccade-related BOLD-activity vs. fixation in patients with PD and in healthy controls and correlated perisaccadic BOLD-activity in PD patients with saccade kinetics (multistep saccades). Saccade related BOLD-activation was found in both PD and healthy participants in the superior parietal cortex (PEF) and the occipital cortex. Our results suggest remarkable hypoactivity of the frontal and supplementary eye fields (FEF and SEF) in PD patients. On the other hand, PD patients showed a statistically more reliable BOLD modulation than healthy participants in the posterior cingulate gyrus, the parahippocampal gyrus, inferior parietal lobule, precuneus and in the middle temporal gyrus. Given abnormal frontal and normal PEF responses, our results suggest that in PD a frontal cortical circuitry, known to be associated with saccade planning, selection, and predicting a metric error of the saccade, is deficient.

  11. Tuning the surface properties of novel ternary iron(III) fluoride-based catalysts using the template effect of the matrix.

    PubMed

    Guo, Ying; Lippitz, Andreas; Saftien, Paul; Unger, Wolfgang E S; Kemnitz, Erhard

    2015-03-21

    Sol-gel prepared ternary FeF3-MgF2 materials have become promising heterogeneous catalysts due to their porosity and surface Lewis/Brønsted acidity (bi-acidity). Despite the good catalytic performance, nanoscopic characterisations of this type of material are still missing and the key factors controlling the surface properties have not yet been identified, impeding both a better understanding and further development of ternary fluoride catalysts. In this study, we characterised the interaction between the bi-acidic component (FeF3) and the matrix (MgF2) on the nano-scale. For the first time, the formation pathway of FeF3-MgF2 was profiled and the template effect of MgF2 during the synthesis process was discovered. Based on these new insights two novel materials, FeF3-CaF2 and FeF3-SrF2, were established, revealing that with decreasing the atomic numbers (from Sr to Mg), the ternary fluorides exhibited increasing surface acidity and surface area but decreasing pore size. These systematic changes gave rise to a panel of catalysts with tuneable surface and bulk properties either by changing the matrix alkaline earth metal fluoride or by adjusting their ratios to Fe or both. The template effect of the alkaline earth metal fluoride matrix was identified as the most probable key factor determining the surface properties and further influencing the catalytic performance in ternary fluoride based catalysts, and paves the way to targeted design of next-generation catalysts with tunable properties.

  12. [Fe(F20 TPP)Cl]-catalyzed amination with arylamines and {[Fe(F20 TPP)(NAr)](PhI=NAr)} + . Intermediate assessed by high-resolution ESI-MS and DFT calculations.

    PubMed

    Liu, Yungen; Chen, Guo-Qiang; Tse, Chun-Wai; Guan, Xianguo; Xu, Zheng-Jiang; Huang, Jie-Sheng; Che, Chi-Ming

    2015-01-01

    Amination of CH bonds catalyzed by transition metal complexes via nitrene/imide insertion is an appealing strategy for CN bond formation, and the use of iminoiodinanes, or their in situ generated forms from 'PhI(OAc)2 +primary amides (such as sulfonamides, sulfamates, and carbamates)', as nitrogen sources for the amination reaction has been well documented. In this work, a 'metal catalyst+PhI(OAc)2 +primary arylamines' amination protocol has been developed using [Fe(F20 TPP)Cl] (H2 F20 TPP=meso-tetrakis(pentafluorophenyl)porphyrin) as a catalyst. This catalytic method is applicable for both intra- and intermolecular amination of sp(2) and sp(3) CH bonds (>27 examples), affording the amination products, including natural products such as rutaecarpine, in moderate-to-good yields. ESI-MS analysis and DFT calculations lend support for the involvement of {[Fe(F20 TPP)(NC6 H4 -p-NO2 )](PhI=NC6 H4 -p-NO2 )} + . intermediate in the catalysis. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Monitoring Doppler patterns and clinical parameters may predict feeding tolerance in intrauterine growth-restricted infants.

    PubMed

    Bozzetti, Valentina; Paterlini, Giuseppe; Gazzolo, Diego; Van Bel, Frank; Visser, Gerard H A; Roncaglia, Nadia; Tagliabue, Paolo E

    2013-11-01

    To detect predictors of feeding tolerance in intrauterine growth restriction (IUGR) infants with or without brain-sparing effect (BS). We conducted a case-control study in 70 IUGR infants (35 IUGR with BS, matched for gestational age with 35 IUGR infants with no BS). BS was classified as pulsatility index (PI) ratio [umbilical artery (UAPI) to middle cerebral artery (MCAPI) (U/C ratio)] > 1. Clinical parameters of feeding tolerance - days to achieve full enteral feeding (FEF) - were compared between the IUGR with BS and IUGR without BS infants. Age at the start of minimal enteral feeding (MEF) was analysed. Achievement of FEF was significantly shorter in IUGR infants without BS than in IUGR with BS. IUGR with BS started MEF later than IUGR without BS infants. Significant correlation of MEF and FEF with UA PI, U/C ratio and CRIB score was found. Multiple linear regression analysis showed significant correlations with CRIB score and caffeine administration (MEF only), and sepsis (FEF only) and U/C ratio (for both). Impaired gut function can be early detected by monitoring Doppler patterns and clinical parameters. ©2013 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  14. Thin films as a platform for understanding the conversion mechanism of FeF2 cathodes in lithium-ion microbatteries

    NASA Astrophysics Data System (ADS)

    Santos-Ortiz, Reinaldo

    Conversion material electrodes such as FeF2 possess the potential to deliver transformative improvements in lithium ion battery performance because they permit a reversible change of more than one Li-ion per 3d metal cation. They outperform current state of the art intercalation cathodes such as LiCoO2, which have volumetric and gravimetric energy densities that are intrinsically limited by single electron transfer. Current studies focus on composite electrodes that are formed by mixing with carbon (FeF 2-C), wherein the carbon is expected to act as a binder to support the matrix and facilitate electronic conduction. These binders complicate the understanding of the electrode-electrolyte interface (SEI) passivation layer growth, of Li agglomeration, of ion and electron transport, and of the basic phase transformation processes under electrochemical cycling. This research uses thin-films as a model platform for obtaining basic understanding to the structural and chemical foundations of the phase conversion processes. Thin film cathodes are free of the binders used in nanocomposite structures and may potentially provide direct basic insight to the evolution of the SEI passivation layer, electron and ion transport, and the electrochemical behavior of true complex phases. The present work consisted of three main tasks (1) Development of optimized processes to deposit FeF2 and LiPON thin-films with the required phase purity and microstructure; (2) Understanding their electron and ion transport properties and; (3) Obtaining insight to the correlation between structure and capacity in thin-film microbatteries with FeF2 thin-film cathode and LiPON thin-film solid electrolyte. Optimized pulsed laser deposition (PLD) growth produced polycrystalline FeF2 films with excellent phase purity and P42/mnm crystallographic symmetry. A schematic band diagram was deduced using a combination of UPS, XPS and UV-Vis spectroscopies. Room temperature Hall measurements reveal that as-deposited FeF2 is n-type with an electron mobility of 0.33 cm 2/V.s and a resistivity was 0.255 O.cm. The LiPON films were deposited by reactive sputtering in nitrogen, and the results indicate that the ionic conductivity is dependent on the amount of nitrogen incorporated into the film during processing. The highest ionic conductivity obtained was 1.431.9E-6 Scm-1 and corresponded to a chemical composition of Li1.9PO3.3N.21.

  15. Soil variability along a nitrogen mineralization and nitrification gradient in a nitrogen-saturated hardwood forest

    Treesearch

    Frank S. Gilliam; Nikki L. Lyttle; Ashley Thomas; Mary Beth Adams

    2005-01-01

    Some N-saturated watersheds of the Fernow Experimental Forest (FEF), West Virginia, exhibit a high degree of spatial heterogeneity in soil N processing. We used soils from four sites at FEF representing a gradient in net N mineralization and nitrification to consider the causes and consequences of such spatial heterogeneity. We collected soils with extremely high vs....

  16. Top-down modulation from inferior frontal junction to FEFs and intraparietal sulcus during short-term memory for visual features.

    PubMed

    Sneve, Markus H; Magnussen, Svein; Alnæs, Dag; Endestad, Tor; D'Esposito, Mark

    2013-11-01

    Visual STM of simple features is achieved through interactions between retinotopic visual cortex and a set of frontal and parietal regions. In the present fMRI study, we investigated effective connectivity between central nodes in this network during the different task epochs of a modified delayed orientation discrimination task. Our univariate analyses demonstrate that the inferior frontal junction (IFJ) is preferentially involved in memory encoding, whereas activity in the putative FEFs and anterior intraparietal sulcus (aIPS) remains elevated throughout periods of memory maintenance. We have earlier reported, using the same task, that areas in visual cortex sustain information about task-relevant stimulus properties during delay intervals [Sneve, M. H., Alnæs, D., Endestad, T., Greenlee, M. W., & Magnussen, S. Visual short-term memory: Activity supporting encoding and maintenance in retinotopic visual cortex. Neuroimage, 63, 166-178, 2012]. To elucidate the temporal dynamics of the IFJ-FEF-aIPS-visual cortex network during memory operations, we estimated Granger causality effects between these regions with fMRI data representing memory encoding/maintenance as well as during memory retrieval. We also investigated a set of control conditions involving active processing of stimuli not associated with a memory task and passive viewing. In line with the developing understanding of IFJ as a region critical for control processes with a possible initiating role in visual STM operations, we observed influence from IFJ to FEF and aIPS during memory encoding. Furthermore, FEF predicted activity in a set of higher-order visual areas during memory retrieval, a finding consistent with its suggested role in top-down biasing of sensory cortex.

  17. Acidic attack of perfluorinated alkyl ether lubricant molecules by metal oxide surfaces

    NASA Technical Reports Server (NTRS)

    Zehe, Michael J.; Faut, Owen D.

    1990-01-01

    The reactions of linear perfluoropolyalkylether (PFAE) lubricants with alpha-Fe203 and Fe203-based solid superacids were studied. The reaction with alpha-Fe203 proceeds in two stages. The first stage is an initial slow catalytic decomposition of the fluid. This reaction releases reactive gaseous products which attach the metal oxide and convert it to FeF3. The second stage is a more rapid decomposition of the fluid, effected by the surface FeF3. A study of the initial breakdown step was performed using alpha-Fe203, alpha-Fe203 preconverted to FeF3, and sulfate-promoted alpha-Fe203 superacids. The results indicate that the breakdown reaction involves acidic attack at fluorine atoms on acetal carbons in the linear PFAE. Possible approaches to combat the problem are outlined.

  18. Hemispheric differences in the voluntary control of spatial attention: direct evidence for a right-hemispheric dominance within frontal cortex.

    PubMed

    Duecker, Felix; Formisano, Elia; Sack, Alexander T

    2013-08-01

    Lesion studies in neglect patients have inspired two competing models of spatial attention control, namely, Heilman's "hemispatial" theory and Kinsbourne's "opponent processor" model. Both assume a functional asymmetry between the two hemispheres but propose very different mechanisms. Neuroimaging studies have identified a bilateral dorsal frontoparietal network underlying voluntary shifts of spatial attention. However, lateralization of attentional processes within this network has not been consistently reported. In the current study, we aimed to provide direct evidence concerning the functional asymmetry of the right and left FEF during voluntary shifts of spatial attention. To this end, we applied fMRI-guided neuronavigation to disrupt individual FEF activation foci with a longer-lasting inhibitory patterned TMS protocol followed by a spatial cueing task. Our results indicate that right FEF stimulation impaired the ability of shifting spatial attention toward both hemifields, whereas the effects of left FEF stimulation were limited to the contralateral hemifield. These results provide strong direct evidence for right-hemispheric dominance in spatial attention within frontal cortex supporting Heilman's "hemispatial" theory. This complements previous TMS studies that generally conform to Kinsbourne's "opponent processor" model after disruption of parietal cortex, and we therefore propose that both theories are not mutually exclusive.

  19. Acidic attack of perfluorinated alkyl ether lubricant molecules by metal oxide surfaces

    NASA Technical Reports Server (NTRS)

    Zehe, Michael J.; Faut, Owen D.

    1989-01-01

    The reactions of linear perfluoropolyalkylether (PFAE) lubricants with alpha-Fe2O3 and Fe2O3-based solid superacids were studied. The reaction with alpha-Fe2O3 proceeds in two stages. The first stage is an initial slow catalytic decomposition of the fluid. This reaction releases reactive gaseous products which attach the metal oxide and convert it to FeF3. The second stage is a more rapid decomposition of the fluid, effected by the surface FeF3. A study of the inital breakdown step was performed using alpha-Fe2O3, alpha-Fe2O3 preconverted to FeF3, and sulfate-promoted alpha-Fe2O3 superacids. The results indicate that the breakdown reaction involves acidic attack at fluorine atoms on acetal carbons in the linear PFAE. Possible approaches to combat the problem are outlined.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goren, A.I.; Brenner, S.; Hellmann, S.

    During the summer of 1984 a health survey was carried out among the population of six rural settlements, three in a polluted and three in a low polluted area. Residents of these settlements between 6 and 65 years of age filled out an ATS-NHLI health questionnaire and performed the following pulmonary function tests (PFT): FVC, FEV/sub 1/, FEV/sub 1//FVC, PEF, FEF/sub 50/, and FEF/sub 75/. A trend of higher prevalence of reported respiratory symptoms and diseases characterizes children growing up in a polluted rural as compared with a low polluted rural area. The relative risks (calculated from logistic models) formore » children from the polluted area to have sputum with cold is 2.13, cough accompanied by sputum 3.89, and for their siblings to have respiratory diseases 3.02, as compared with 1.00 in the low polluted area. A trend of lower PFT characterizes children from the polluted area, with significantly reduced PEF. The trends for adults in the two areas were similar to those for the children. The relative risks for adults from the polluted area to have sputum is 1.7 and cough accompanied by sputum 2.6, as compared with 1.0 in the low polluted area. PEF is significantly lower among adults from the polluted area, while FEF/sub 50/ and FEF/sub 75/ are lower (not significantly) among adults from the low polluted area.« less

  1. The defensive role of foliar endophytic fungi for a South American tree

    PubMed Central

    González-Teuber, Marcia

    2016-01-01

    Fungal endophytes colonize living internal plant tissues without causing any visible symptoms of disease. Endophytic fungi associated with healthy leaves may play an important role in the protection of hosts against herbivores and pathogens. In this study, the diversity of foliar endophytic fungi (FEF) of the southern temperate tree Embothrium coccineum (Proteaceae), as well as their role in plant protection in nature was determined. Fungal endophytes were isolated from 40 asymptomatic leaves by the culture method for molecular identification of the 18S rRNA gene. A relationship between FEF frequency and plant protection was evaluated in juveniles of E. coccineum. Fungal endophyte frequency was estimated using real-time PCR analyses to determine endophyte DNA content per plant. A total of 178 fungal isolates were identified, with sequence data revealing 34 different operational taxonomic units (OTUs). A few common taxa dominated the fungal endophyte community, whereas most taxa qualified as rare. A significant positive correlation between plant protection (evaluated in terms of percentage of leaf damage) and FEF frequency was found. Furthermore, in vitro confrontation assays indicated that FEF were able to inhibit the growth of fungal pathogens. The data showed a relatively high diversity of fungal endophytes associated with leaves of E. coccineum, and suggest a positive relationship between fungal endophyte frequencies in leaves and host protection in nature. PMID:27339046

  2. Effect of heliox- and air-driven nebulized bronchodilator therapy on lung function in patients with asthma.

    PubMed

    El-Khatib, Mohamad F; Jamaleddine, Ghassan; Kanj, Nadim; Zeineddine, Salah; Chami, Hassan; Bou-Akl, Imad; Husari, Ahmad; Alawieh, Marwan; Bou-Khalil, Pierre

    2014-06-01

    This study compares the effect of heliox-driven to that of air-driven bronchodilator therapy on the pulmonary function test (PFT) in patients with different levels of asthma severity. One-hundred thirty-two participants were included in the study. Participants underwent spirometry twice with bronchodilator testing on two consecutive days. Air-driven nebulization was used one day and heliox-driven nebulization the other day in random order crossover design. After a baseline PFT, each participant received 2.5 mg of albuterol sulfate nebulized with the randomized driving gas. Post bronchodilator PFT was repeated after 30 min. The next day, the exact same protocol was repeated, except that the other driving gas was used to nebulize the drug. Participants were subgrouped and analyzed according to their baseline FEV(1) on day 1: Group I, FEV(1) ≥80 %; Group II, 80 % > FEV(1) > 50 %; Group III, FEV(1) ≤50 %. The proportion of participants with greater than 12 % and 200-mL increases from their baseline FEV(1) and the changes from baseline in PFT variables were compared between heliox-driven versus air-driven bronchodilation therapy. The proportion of participants with >12 % and 200-mL increases from their baseline FEV(1) with air- or heliox-driven bronchodilation was not different with respect to the proportion of participants with baseline FEV(1) ≥80 % (20 vs. 18 %, respectively) and 80 % > FEV(1) > 50 % (36 vs. 43 %, respectively), but it was significantly greater with heliox-driven bronchodilation in participants with FEV(1) ≤50 % (43 vs. 73 %, respectively; p = 0.01). Changes from baseline FVC, FEV(1), FEV(1)/FVC, FEF(25-75) %, FEF(max), FEF(25) %, FEF(50) %, and FEF(75) % were significantly larger with heliox-driven versus air-driven bronchodilation in participants with baseline FEV(1) ≤50 %. Improvements in PFT variables are more frequent and profound with heliox-driven compared to air-driven bronchodilator therapy only in asthmatic patients with baseline FEV(1) ≤50 %.

  3. Fuze Experimentation Facility and Fuze Industrial Facility (FEF/FIF) Construction. Final Environmental Assessment

    DTIC Science & Technology

    2011-04-01

    1-9. R esources N ot C arried Forw ard for D etailed A nalysis Legend Environmental Justice Concerns c:::J Proposed Project Area No Concerns...11 FEF/FIF C onstruction Environm ental A ssessm ent Page 3-6 Eglin A ir Force B ase, FL Final Figure 3-1. W ater R esources A t or N...Ecological A ssociations and Biological R esources A t or N ear the Proposed A ction Location Ecological Association Flatwoods Landscaped!Urban c:J

  4. An epidemiological study of salt miners in diesel and nondiesel mines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gamble, J.; Jones, W.; Hudak, J.

    1983-01-01

    A cross-sectional study of 5 NaCl mines and 259 miners addressed the following questions: 1) Is there an association of increased respiratory symptoms, radiographic findings, and reduced pulmonary function with exposure to nitrogen dioxide (NO2) and/or respirable particulate (RP) among these miners. 2) Is there increased morbidity of these miners compared to other working populations. Personal samples of NO2 and respirable particulate for jobs in each mine were used to estimate cumulative exposure. NO2 is used as a surrogate measure of diesel exposure. Cough was associated with age and smoking, dyspnea with age; neither symptom was associated with exposure (yearsmore » worked, estimated cumulative NO2 or RP exposure). Phlegm was associated with age, smoking, and exposure. Reduced pulmonary function (FVC, FEV1, peak, flow, FEF50, FEF75) showed no association with exposure. There was one case of small rounded and one case of small irregular opacities; pneumoconiosis was not analyzed further. Compared to underground coal miners, above ground coal miners, potash miners, and nonmining workers, the study population after adjustment for age and smoking generally showed no increased prevalence of cough, phlegm, dyspnea, or obstruction (FEV1/FVC less than 0.7). Obstruction in younger salt miners and phlegm in older salt miners was elevated compared to nonmining workers. Mean predicted pulmonary function was reduced 2-4% for FEV1 and FVC, 7-13% for FEF50, and 18-22% for FEF75 below all comparison populations.« less

  5. Relationship between birth weight, maternal smoking during pregnancy and childhood and adolescent lung function: A path analysis.

    PubMed

    Balte, Pallavi; Karmaus, Wilfried; Roberts, Graham; Kurukulaaratchy, Ramesh; Mitchell, Frances; Arshad, Hasan

    2016-12-01

    Low birth weight and gestational maternal smoking have been linked with reduced lung function in children in many cross sectional studies. However, these associations have not yet been assessed with repeated measurements of lung function. Our aim was to investigate the effects of birth weight, gestational age, and gestational maternal smoking on lung function in children at age 10 and 18 years. In the Isle of Wight birth cohort spirometry was performed at age 10 and 18 years. Information on birth weight and gestational age were obtained from hospital records. Mothers were asked about smoking during pregnancy. We employed linear mixed models to estimate the effect of these risk factors on repeated measurements of lung function. We considered maternal asthma, sex, neonatal intensive care unit admission, height, socio-economic status, personal smoking in participants at age 18, body mass index and environmental tobacco smoke exposure as potential confounders. Finally, we used path analysis to determine links between birth weight, gestational age and gestational maternal smoking on lung function at age 10 and 18 years. Linear mixed models showed that with every 1 kg increase in birth weight, Forced expiratory volume in one second (FEV 1 ) increased by 42.6 ± 17.2 mL and Forced expiratory flow between 25% and 75% (FEF 25-75 ) of Forced vital capacity (FVC) increased by 95.5 ± 41.2 mL at age 18 years after adjusting for potential confounders. Path analysis suggested that birth weight had positive direct effects on FEV 1 and FEF 25-75 and positive indirect effect on FVC at 10 years which were carried forward to 18 years. Additionally, results also suggested a positive association between gestational age and FEV 1 , FVC and FEF 25-75  at ages 10 and 18 years and an inverse association between gestational smoke exposure and FEV 1 /FVC ratio and FEF 25-75  at age 18 years. Higher birth weight and gestational age were associated with higher FEV 1 , FVC and FEF 25-75 and maternal smoking during pregnancy was associated with reduced FEV 1 /FVC ratio and FEF 25-75 . The use of path analysis can improve our understanding of underlying "causal" pathways among different prenatal and childhood factors that affect lung function in both pre-adolescent and adolescent periods. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  6. The comparative study of bulk magneto-phonon and magnetic polaritons of lateral antiferromagnetic superlattices for potential THz applications

    NASA Astrophysics Data System (ADS)

    Ta, Jin-Xing; Han, Yu; Lan, Cheng

    2016-02-01

    Bulk magneto-phonon and magnetic polaritons of lateral antiferromagnetic superlattices for potential THz applications have been investigated in the framework of the effective medium theory. The dispersion relations applied for the system are displayed. In contrast with lateral FeF2/SiO2 superlattice, some fascinating polariton modes with negative group velocity signifying photonic band gap scenarios and attractive optical properties are observed from the numerical results presented with the example, lateral FeF2/TlBr superlattice.

  7. Oxidant-antioxidant status and pulmonary function in welding workers.

    PubMed

    Fidan, Fatma; Unlü, Mehmet; Köken, Tülay; Tetik, Levent; Akgün, Sema; Demirel, Reha; Serteser, Mustafa

    2005-07-01

    Welding is a process during which fumes, gases, electromagnetic radiation and noise are emitted as by-products. Metal oxide particles are particularly hazardous components of welding fumes. Welding has been found to be associated with respiratory symptoms and our objective in the present study was to study the effects of welding on pulmonary function and serum oxidant-antioxidant status. Fifty-one welding workers and 31 control subjects were recruited. Face to face interviews were conducted using the respiratory illness questionnaire adapted from the American Thoracic Society with the addition of demographic characteristics, work history and working conditions. Additionally physical examinations and spirometric measurements were performed at workplaces. Thiobarbituric acid reactive substances (TBARS), protein carbonyls, protein sulfhydryls (SH) and erythrocyte reduced glutathione (GSH) levels were measured to evaluate oxidant-antioxidant status in 34 welding workers and in 20 control subjects. No statistically significant differences were observed in age, height, weight, body mass index (BMI), smoking status and annual working durations between welding workers and controls. Coughing, sputting and wheezing were significantly higher in welding workers (p<0.05). When adjusted for age, BMI and smoking status in logistic regression, welding work showed a significant risk for chronic bronchitis (OR: 4.78, 95%CI: 1.30-17.54). Forced expiratory volume in one second (FEV(1))/forced vital capacity (FVC) and four parameters of forced expiratory flow (FEF: FEF(25), FEF(50), FEF(75), FEF(25-75)) levels measured in the welding workers were significantly lower than those in the control group (p<0.05). Serum TBARS and protein carbonyl levels were higher in welding workers than those in controls (p<0.001, p<0.05, respectively). On the other hand, total protein SH groups and GSH levels were significantly lower in welders than those in controls (p<0.05, p<0.001, respectively). Pulmonary function tests and oxidant-antioxidant status were found to be negatively affected in welding workers chronically exposed to welding fumes and gases. Preventive measures should be taken to improve the health status of these workers.

  8. Improved pulmonary function in working divers breathing nitrox at shallow depths

    NASA Technical Reports Server (NTRS)

    Fitzpatrick, Daniel T.; Conkin, Johnny

    2003-01-01

    INTRODUCTION: There is limited data about the long-term pulmonary effects of nitrox use in divers at shallow depths. This study examined changes in pulmonary function in a cohort of working divers breathing a 46% oxygen enriched mixture while diving at depths less than 12 m. METHODS: A total of 43 working divers from the Neutral Buoyancy Laboratory (NBL), NASA-Johnson Space Center completed a questionnaire providing information on diving history prior to NBL employment, diving history outside the NBL since employment, and smoking history. Cumulative dive hours were obtained from the NBL dive-time database. Medical records were reviewed to obtain the diver's height, weight, and pulmonary function measurements from initial pre-dive, first year and third year annual medical examinations. RESULTS: The initial forced vital capacity (FVC) and forced expiratory volume in 1 s (FEV1) were greater than predicted, 104% and 102%, respectively. After 3 yr of diving at the NBL, both the FVC and FEV1 showed a significant (p < 0.01) increase of 6.3% and 5.5%, respectively. There were no significant changes in peak expiratory flow (PEF), forced mid-expiratory flow rate (FEF(25-75%)), and forced expiratory flow rates at 25%, 50%, and 75% of FVC expired (FEF25%, FEF50%, FEF75%). Cumulative NBL dive hours was the only contributing variable found to be significantly associated with both FVC and FEV1 at 1 and 3 yr. CONCLUSIONS: NBL divers initially belong to a select group with larger than predicted lung volumes. Regular diving with nitrox at shallow depths over a 3-yr period did not impair pulmonary function. Improvements in FVC and FEV1 were primarily due to a training effect.

  9. Effects of indoor air pollution on lung function of primary school children in Kuala Lumpur

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Azizi, B.H.; Henry, R.L.

    1990-01-01

    In a cross-sectional study of 7-12 year-old primary school children in Kuala Lumpur city, lung function was assessed by spirometric and peak expiratory flow measurements. Spirometric and peak expiratory flow measurements were successfully performed in 1,214 and 1,414 children, respectively. As expected, the main predictors of forced vital capacity (FVC), forced expiratory volume in one second (FEV1), forced expiratory flow between 25% and 75% of vital capacity (FEF25-75), and peak expiratory flow rate (PEFR) were standing height, weight, age, and sex. In addition, lung function values of Chinese and Malays were generally higher than those of Indians. In multiple regressionmore » models which included host and environmental factors, asthma was associated with significant decreases in FEV1, FEF25-75, and PEFR. However, family history of chest illness, history of allergies, low paternal education, and hospitalization during the neonatal period were not independent predictors of lung function. Children sharing rooms with adult smokers had significantly lower levels of FEF25-75. Exposures to wood or kerosene stoves were, but to mosquito repellents were not, associated with decreased lung function.« less

  10. Assessment of the vision-specific quality of life using clustered visual field in glaucoma patients.

    PubMed

    Sawada, Hideko; Yoshino, Takaiko; Fukuchi, Takeo; Abe, Haruki

    2014-02-01

    To investigate the significance of vision-specific quality of life (QOL) in glaucoma patients based on the location of visual field defects. We examined 336 eyes of 168 patients. The 25-item National Eye Institute Visual Function Questionnaire was used to evaluate patients' QOL. Visual field testing was performed using the Humphrey Field Analyzer; the visual field was divided into 10 clusters. We defined the eye with better mean deviation as the better eye and the fellow eye as the worse eye. A single linear regression analysis was applied to assess the significance of the relationship between QOL and the clustered visual field. The strongest correlation was observed in the lower paracentral visual field in the better eye. The lower peripheral visual field in the better eye also showed a good correlation. Correlation coefficients in the better eye were generally higher than those in the worse eye. For driving, the upper temporal visual field in the better eye was the most strongly correlated (r=0.509). For role limitation and peripheral vision, the lower peripheral visual field in the better eye had the highest correlation coefficients at 0.459 and 0.425, respectively. Overall, clusters in the lower hemifield in the better eye were more strongly correlated with QOL than those in the worse eye. In particular, the lower paracentral visual field in the better eye was correlated most strongly of all. Driving, however, strongly correlated with the upper hemifield in the better eye.

  11. Ab initio study of the diatomic fluorides FeF, CoF, NiF, and CuF.

    PubMed

    Koukounas, Constantine; Mavridis, Aristides

    2008-11-06

    The late-3d transition-metal diatomic fluorides MF = FeF, CoF, NiF, and CuF have been studied using variational multireference (MRCI) and coupled-cluster [RCCSD(T)] methods, combined with large to very large basis sets. We examined a total of 35 (2S+1)|Lambda| states, constructing as well 29 full potential energy curves through the MRCI method. All examined states are ionic, diabatically correlating to M(+)+F(-)((1)S). Notwithstanding the "eccentric" character of the 3d transition metals and the difficulties to accurately be described with all-electron ab initio methods, our results are, in general, in very good agreement with available experimental numbers.

  12. EELS Valence Mapping in Electron Beam Sensitive FeFx/C Nanocomposites

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cosandey, F.; Al-Sharab, J.F.; Amatucci, Glenn G.

    A new type of positive electrodes for Li-Ion batteries has been synthesized based on FeF{sub 2}/C and FeF3/C nanocomposites with particle size in the 8-12 nm range [1]. The measured high capacities rely on a complete reduction of Fe to its metallic state according to the following reaction: xLi{sup +}+xe{sup -} +Fe{sup x+}Fx = xLiF + Fe{sup 0}, where x=3 and x=2 for FeF3/C and FeF2/C respectively. This electrochemical reaction involves a change in valence state of Fe from 3+ or 2+ to 0 that can be determined uniquely by EELS from the peak energy of the L{sub 3} linemore » and from the L{sub 3}/L{sub 2} line intensity ratio. In this paper, we report EELS mapping results on the electrochemical conversion processes and in particular the mapping of the Fe valence state before and after discharge. This work was performed with a Hitachi HF2000 equipped with a Gatan PEELS and with a FEI CM200 FEG TEM equipped with a Gatan GIF. Both instruments were operated in STEM mode at 200kV with an EELS collection half angle of {beta}=5 mrad and spectrum imaging software.« less

  13. Common cold decreases lung function in infants with recurrent wheezing.

    PubMed

    Mallol, J; Aguirre, V; Wandalsen, G

    2010-01-01

    Common acute viral respiratory infections (colds) are the most frequent cause of exacerbations in infants with recurrent wheezing (RW). However, there is no quantitative information about the effect of colds on the lung function of infants with RW. This study was undertaken to determine the effect of common cold on forced expiratory parameters measured from raised lung volume in infants with RW. Spirometric lung function (expiratory flows from raised lung volume) was randomly assessed in 28 infants with RW while they had a common cold and when asymptomatic. It was found that during colds there was a significant decrease in all forced expiratory parameters and this was much more evident for flows (FEF(50%), FEF(75%) and FEF(25-75%)) which were definitively abnormal (less than -1.65 z-score) in the majority of infants. There was not association between family asthma, tobacco exposure, and other factors, with the extent of lung function decrease during colds. Tobacco during pregnancy but not a history of family asthma was significantly associated to lower expiratory flows; however, the association was significant only when infants were asymptomatic. This study shows that common colds cause a marked reduction of lung function in infants with RW. 2009 SEICAP. Published by Elsevier Espana. All rights reserved.

  14. High second-harmonic generation of antiferromagnetic/ionic-crystal composite medium with negative refraction

    NASA Astrophysics Data System (ADS)

    Song, Yu-Ling; Ta, Jin-Xing; Wang, Xuan-Zhang

    2012-03-01

    Second harmonic generation (SHG) from a short-period structure composed of alternating antiferromagnetic (AF) and ionic-crystal layers is investigated, where the generated harmonic waves are situated in the far-infrared range and attributed to the magnetically nonlinear interaction in AF layers. The presence of a kind of appropriate ionic-crystal layers in the structure can support negative refraction for the pumping wave and positive refraction for the SH wave, so the SHG is greatly amplified in the vicinity of each AF resonant frequency. For the composite structure FeF2/TlBr, we found that the SH output is about 8 times higher than that of the FeF2 bulk in the same frequency range.

  15. Ultrawide-field Fluorescein Angiography for Evaluation of Diabetic Retinopathy

    PubMed Central

    Kong, Mingui; Lee, Mee Yon

    2012-01-01

    Purpose To investigate the advantages of ultrawide-field fluorescein angiography (FA) over the standard fundus examination in the evaluation of diabetic retinopathy (DR). Methods Ultrawide-field FAs were obtained in 118 eyes of 59 diabetic patients; 11 eyes with no DR, 71 eyes with nonproliferative diabetic retinopathy (NPDR), and 36 eyes with proliferative diabetic retinopathy (PDR), diagnosed by the standard method. The presence of peripheral abnormal lesions beyond the standard seven fields was examined. Results Ultrawide-field FA images demonstrated peripheral microaneurysms in six (54.5%) of 11 eyes with no DR and all eyes with moderate to severe NPDR and PDR. Peripheral retinal neovascularizations were detected in three (4.2%) of 71 eyes with NPDR and in 13 (36.1%) of 36 eyes with PDR. Peripheral vascular nonperfusion and vascular leakage were found in two-thirds of eyes with severe NPDR and PDR. Conclusions Ultrawide-field FA demonstrates peripheral lesions beyond standard fields, which can allow early detection and a close evaluation of DR. PMID:23204797

  16. Study of spirometry in children from Mexico City

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Namihira, D.; Strope, G.L.; Helms, R.W.

    1986-11-01

    A study was conducted in two elementary schools in Mexico City to determine values for pulmonary function tests in school-aged residents of Mexico City. The schools were located in Xalostoc, a highly industrialized area of Mexico City, and San Lorenzo, a suburban area of the city. Although data regarding atmospheric pollution were not available, there is an acknowledged higher level of macroenvironmental air pollution in Xalostoc. Pulmonary function tests were performed on 468 children in San Lorenzo and 405 children in Xalostoc. No differences between residents of the two communities for acute or chronic respiratory conditions were detected by questionnaire.more » The pulmonary function data demonstrate that boys have larger forced vital capacities (FVC) and forced expiratory flows over the middle half of the FVC (FEF25-75) than girls. Slopes of regression lines for FVC but not for FEF25-75 are greater in boys and girls from Xalostoc than in boys and girls from San Lorenzo. This suggests that young children from Xalostoc may experience ill effects of air pollution but develop catch-up growth later. There were no important community or gender effects on slopes of regression lines for height and weight on age. In general, the regression lines for FVC and FEF25-75 were below regression lines reported for children of Mexican ancestry living at sea level.« less

  17. An fMRI Investigation of Preparatory Set in the Human Cerebral Cortex and Superior Colliculus for Pro- and Anti-Saccades

    PubMed Central

    Furlan, Michele; Smith, Andrew T.; Walker, Robin

    2016-01-01

    Previous studies have identified several cortical regions that show larger BOLD responses during preparation and execution of anti-saccades than pro-saccades. We confirmed this finding with a greater BOLD response for anti-saccades than pro-saccades during the preparation phase in the FEF, IPS and DLPFC and in the FEF and IPS in the execution phase. We then applied multi-voxel pattern analysis (MVPA) to establish whether different neural populations are involved in the two types of saccade. Pro-saccades and anti-saccades were reliably decoded during saccade execution in all three cortical regions (FEF, DLPFC and IPS) and in IPS during saccade preparation. This indicates neural specialization, for programming the desired response depending on the task rule, in these regions. In a further study tailored for imaging the superior colliculus in the midbrain a similar magnitude BOLD response was observed for pro-saccades and anti-saccades and the two saccade types could not be decoded with MVPA. This was the case both for activity related to the preparation phase and also for that elicited during the execution phase. We conclude that separate cortical neural populations are involved in the task-specific programming of a saccade while in contrast, the SC has a role in response preparation but may be less involved in high-level, task-specific aspects of the control of saccades. PMID:27391390

  18. Advanced Electrode Materials for High Energy Next Generation Li ion Batteries

    NASA Astrophysics Data System (ADS)

    Hayner, Cary Michael

    Lithium ion batteries are becoming an increasingly ubiquitous part of modern society. Since their commercial introduction by Sony in 1991, lithium-ion batteries have grown to be the most popular form of electrical energy storage for portable applications. Today, lithium-ion batteries power everything from cellphones and electric vehicles to e-cigarettes, satellites, and electric aircraft. Despite the commercialization of lithium-ion batteries over twenty years ago, it remains the most active field of energy storage research for its potential improvement over current technology. In order to capitalize on these opportunities, new materials with higher energy density and storage capacities must be developed. Unfortunately, most next-generation materials suffer from rapid capacity degradation or severe loss of capacity when rapidly discharged. In this dissertation, the development of novel anode and cathode materials for advanced high-energy and high-power lithium-ion batteries is reported. In particular, the application of graphene-based materials to stabilize active material is emphasized. Graphene, a unique two-dimensional material composed of atomically thin carbon sheets, has shown potential to address unsatisfactory rate capability, limited cycling performance and abrupt failure of these next-generation materials. This dissertation covers four major subjects: development of silicon-graphene composites, impact of carbon vacancies on graphene high-rate performance, iron fluoride-graphene composites, and ternary iron-manganese fluoride synthesis. Silicon is considered the most likely material to replace graphite as the anode active material for lithium-ion batteries due to its ability to alloy with large amounts of lithium, leading to significantly higher specific capacities than the graphite standard. However, Si also expands in size over 300% upon lithiation, leading to particle fracture and isolation from conductive support, resulting in cell failure within a few charge-discharge cycles. To stabilize silicon materials, composites of silicon nanoparticles were dispersed between graphene sheets and supported by a 3-D network of graphite formed by reconstituted regions of graphene stacks. These free-standing, self-supported composites exhibited excellent Li-ion storage capacities higher than 2200 mAh/g and good cycling stability. In order to improve the advantages graphene can provide as a 3-D scaffold, carbon vacancies were introduced into the basal planes via an acid-oxidation treatment. These vacancies markedly enhance the rate performance of graphene materials as well as silicon-graphene composites. Silicon-graphene composites containing carbon vacancies achieved high accessible storage capacities at fast charge/discharge rates that rival supercapacitor performance while maintaining good cycling stability. Optimal carbon vacancy size and density were determined. Graphene composites were also formed with iron trifluoride (FeF 3), a high-energy cathode material with ability to store up to 712 mAh/g capacity, over 3X more than current state-of-the-art cathode materials. A facile route that combines co-assembly and photothermal reduction was developed to synthesize free-standing, flexible FeF3/graphene papers. The papers contained a uniform dispersion of FeF3 nanoparticles (< 40 nm) and open ion diffusion channels in the porous, conducting network of graphene sheets that resulted in a flexible paper cathode with high charge storage capacity, rate, and cycling performance, without the need for other carbon additives or binder. Free-standing FeF3/graphene composites showed a high storage capacity of >400 mAh/g and improved cycling performance compared to bare FeF3 particles. Lastly, novel ternary iron-manganese fluoride (FexMn 1-xF2) cathode materials were synthesized via a convenient, bottom-up solution-phase synthesis which allowed control of particle size, shape, and surface morphology. The synthesized materials exhibited nanoscale features with average particle size of 20-40 nm. These ternary metal composites exhibited key, desirable properties for next-generation Li-ion battery cathode materials. The described process constituted a translatable route to large-scale production of ternary metal fluoride nanoparticles.

  19. Electronic structure and magnetic anisotropies of antiferromagnetic transition-metal difluorides

    NASA Astrophysics Data System (ADS)

    Corrêa, Cinthia Antunes; Výborný, Karel

    2018-06-01

    We compare calculations based on density functional theory (DFT) with available experimental data and analyze the origin of magnetic anisotropies in MnF2, FeF2, CoF2, and NiF2. We confirm that the magnetic anisotropy of MnF2 stems almost completely from the dipolar interaction, while magnetocrystalline anisotropy energy (originating in spin-orbit interaction) plays a dominant role in the other three compounds, and discuss how it depends on the details of band structure. The latter is critically compared to available optical measurements. The case of CoF2, where magnetocrystalline anisotropy energy strongly depends on U (the Hubbard parameter in DFT +U ), is put into contrast with FeF2 where theoretical predictions of magnetic anisotropies are nearly quantitative.

  20. Auditory Conflict Resolution Correlates with Medial–Lateral Frontal Theta/Alpha Phase Synchrony

    PubMed Central

    Huang, Samantha; Rossi, Stephanie; Hämäläinen, Matti; Ahveninen, Jyrki

    2014-01-01

    When multiple persons speak simultaneously, it may be difficult for the listener to direct attention to correct sound objects among conflicting ones. This could occur, for example, in an emergency situation in which one hears conflicting instructions and the loudest, instead of the wisest, voice prevails. Here, we used cortically-constrained oscillatory MEG/EEG estimates to examine how different brain regions, including caudal anterior cingulate (cACC) and dorsolateral prefrontal cortices (DLPFC), work together to resolve these kinds of auditory conflicts. During an auditory flanker interference task, subjects were presented with sound patterns consisting of three different voices, from three different directions (45° left, straight ahead, 45° right), sounding out either the letters “A” or “O”. They were asked to discriminate which sound was presented centrally and ignore the flanking distracters that were phonetically either congruent (50%) or incongruent (50%) with the target. Our cortical MEG/EEG oscillatory estimates demonstrated a direct relationship between performance and brain activity, showing that efficient conflict resolution, as measured with reduced conflict-induced RT lags, is predicted by theta/alpha phase coupling between cACC and right lateral frontal cortex regions intersecting the right frontal eye fields (FEF) and DLPFC, as well as by increased pre-stimulus gamma (60–110 Hz) power in the left inferior fontal cortex. Notably, cACC connectivity patterns that correlated with behavioral conflict-resolution measures were found during both the pre-stimulus and the pre-response periods. Our data provide evidence that, instead of being only transiently activated upon conflict detection, cACC is involved in sustained engagement of attentional resources required for effective sound object selection performance. PMID:25343503

  1. Auditory conflict resolution correlates with medial-lateral frontal theta/alpha phase synchrony.

    PubMed

    Huang, Samantha; Rossi, Stephanie; Hämäläinen, Matti; Ahveninen, Jyrki

    2014-01-01

    When multiple persons speak simultaneously, it may be difficult for the listener to direct attention to correct sound objects among conflicting ones. This could occur, for example, in an emergency situation in which one hears conflicting instructions and the loudest, instead of the wisest, voice prevails. Here, we used cortically-constrained oscillatory MEG/EEG estimates to examine how different brain regions, including caudal anterior cingulate (cACC) and dorsolateral prefrontal cortices (DLPFC), work together to resolve these kinds of auditory conflicts. During an auditory flanker interference task, subjects were presented with sound patterns consisting of three different voices, from three different directions (45° left, straight ahead, 45° right), sounding out either the letters "A" or "O". They were asked to discriminate which sound was presented centrally and ignore the flanking distracters that were phonetically either congruent (50%) or incongruent (50%) with the target. Our cortical MEG/EEG oscillatory estimates demonstrated a direct relationship between performance and brain activity, showing that efficient conflict resolution, as measured with reduced conflict-induced RT lags, is predicted by theta/alpha phase coupling between cACC and right lateral frontal cortex regions intersecting the right frontal eye fields (FEF) and DLPFC, as well as by increased pre-stimulus gamma (60-110 Hz) power in the left inferior fontal cortex. Notably, cACC connectivity patterns that correlated with behavioral conflict-resolution measures were found during both the pre-stimulus and the pre-response periods. Our data provide evidence that, instead of being only transiently activated upon conflict detection, cACC is involved in sustained engagement of attentional resources required for effective sound object selection performance.

  2. Distinct representations for shifts of spatial attention and changes of reward contingencies in the human brain.

    PubMed

    Tosoni, Annalisa; Shulman, Gordon L; Pope, Anna L W; McAvoy, Mark P; Corbetta, Maurizio

    2013-06-01

    Success in a dynamically changing world requires both rapid shifts of attention to the location of important objects and the detection of changes in motivational contingencies that may alter future behavior. Here we addressed the relationship between these two processes by measuring the blood-oxygenation-level-dependent (BOLD) signal during a visual search task in which the location and the color of a salient cue respectively indicated where a rewarded target would appear and the monetary gain (large or small) associated with its detection. While cues that either shifted or maintained attention were presented every 4 to 8 sec, the reward magnitude indicated by the cue changed roughly every 30 sec, allowing us to distinguish a change in expected reward magnitude from a maintained state of expected reward magnitude. Posterior cingulate cortex was modulated by cues signaling an increase in expected reward magnitude, but not by cues for shifting versus maintaining spatial attention. Dorsal fronto-parietal regions in precuneus and frontal eye field (FEF) also showed increased BOLD activity for changes in expected reward magnitude from low to high, but in addition showed large independent modulations for shifting versus maintaining attention. In particular, the differential activation for shifting versus maintaining attention was not affected by expected reward magnitude. These results indicate that BOLD activations for shifts of attention and increases in expected reward magnitude are largely separate. Finally, visual cortex showed sustained spatially selective signals that were significantly enhanced when greater reward magnitude was expected, but this reward-related modulation was not observed in spatially selective regions of dorsal fronto-parietal cortex. Copyright © 2012 Elsevier Ltd. All rights reserved.

  3. Retinotopic patterns of background connectivity between V1 and fronto-parietal cortex are modulated by task demands

    PubMed Central

    Griffis, Joseph C.; Elkhetali, Abdurahman S.; Burge, Wesley K.; Chen, Richard H.; Visscher, Kristina M.

    2015-01-01

    Attention facilitates the processing of task-relevant visual information and suppresses interference from task-irrelevant information. Modulations of neural activity in visual cortex depend on attention, and likely result from signals originating in fronto-parietal and cingulo-opercular regions of cortex. Here, we tested the hypothesis that attentional facilitation of visual processing is accomplished in part by changes in how brain networks involved in attentional control interact with sectors of V1 that represent different retinal eccentricities. We measured the strength of background connectivity between fronto-parietal and cingulo-opercular regions with different eccentricity sectors in V1 using functional MRI data that were collected while participants performed tasks involving attention to either a centrally presented visual stimulus or a simultaneously presented auditory stimulus. We found that when the visual stimulus was attended, background connectivity between V1 and the left frontal eye fields (FEF), left intraparietal sulcus (IPS), and right IPS varied strongly across different eccentricity sectors in V1 so that foveal sectors were more strongly connected than peripheral sectors. This retinotopic gradient was weaker when the visual stimulus was ignored, indicating that it was driven by attentional effects. Greater task-driven differences between foveal and peripheral sectors in background connectivity to these regions were associated with better performance on the visual task and faster response times on correct trials. These findings are consistent with the notion that attention drives the configuration of task-specific functional pathways that enable the prioritized processing of task-relevant visual information, and show that the prioritization of visual information by attentional processes may be encoded in the retinotopic gradient of connectivty between V1 and fronto-parietal regions. PMID:26106320

  4. Fluoride Thin Films: from Exchange Bias to Multferroicity

    NASA Astrophysics Data System (ADS)

    Johnson, Trent A.

    This dissertation concerns research into the growth and characterization fluoride thin films by molecular beam epitaxy. After a discussion of relevant background material and experimental procedures in the first two chapters, we study exchange bias in magnetic multilayers incorporating the uniaxial antiferromagnet FeF2, grown to varying thicknesses, sandwiched between ferromagnetic Co layers with fixed thicknesses of 5 and 20 nm. Several bilayers with only the 20 nm thick Co layer were grown for comparative study. The samples were grown on Al2O3 (112¯0) substrates at room temperature. In-situ RHEED and x-ray diffraction indicated the films were polycrystalline. The films were determined to have low surface and interlayer roughness, as determined by AFM and x-ray reflectivity. After field-cooling to below the Neel temperature of FeF2 in a magnetic field of 1 kOe, magnetic hysteresis loops were measured as a function of temperature. We found that both layers had a negative exchange bias, with the exchange bias of the thinner layer larger than that of the thicker layer. In addition, the coercivity below the blocking temperature TB of the thinner layer was significantly larger than that of the thick layer, even though the coercivity of the two layers was the same for T > TB. The exchange bias effect, manifested by a shift in these hysteresis loops, showed a strong dependence on the thickness of the antiferromagnet. Anisotropic magnetoresistance measurements provided additional insight into the magnetization reversal mechanism within the ferromagnets. The thickness dependent exchange anisotropy of trilayer and bilayer samples is explained by adapting a random field model to the antiferromagnet/ferromagnet interface. Finally, We investigate the temperature dependent growth, as well as the magnetic and ferroelectric properties of thin films of the multiferroic compounds BaMF4, where M = Fe, Co, Ni. The films were grown to thicknesses of 50 or 100 nm on single crystal Al2O3 (0001) substrates. X-ray diffraction showed that this family of films grew epitaxially in the (010) orientation, but were twinned in the plane, with three domain orientations rotated by 120 degrees relative to one another. Measurements of the remanent hysteresis via interdigitated electrodes showed that the compounds M = Co, and Ni were ferroelectric, but no switching behavior was observed in the Fe system at electric fields up to 400 kV/cm. Measurements of the field-cooled and zero-field-cooled magnetic moment confirmed low temperature antiferromagnetic behavior, and found new weak ferromagnetic phases induced by strain.

  5. The Effects of Ramadan Fasting on the Spirometric Data of Healthy Adult Males.

    PubMed

    Latiri, Imed; Sandid, Siwar; Fennani, Mohamed Amine; Hadrich, Mohamed; Masmoudi, Tasnim; Maatoug, Chiraz; Zammit-Chatti, Makrem; Chamari, Karim; Ben Saad, Helmi

    2017-07-01

    The few studies carried out on the effects of Ramadan fasting (RF) on spirometric values present contradictory conclusions. This study aimed at assessing whether RF affects healthy adults' spirometric values. Twenty-nine nonsmoking healthy males ( M ± standard error of mean [ SEM] of age: 27 ± 1 years) who fasted during Ramadan (June 29-July 28, 2014) volunteered to the study. Three periods (before-Ramadan [June 23-25], mid-Ramadan [July 14-16] and after-Ramadan [August 11-14]) were selected for spirometry measurements that were consistently performed 5.5 to 3.5 hours (between 15:00 and 17:00 hours) before fasting break. Assessment sessions comprised following: weight (kg), forced vital capacity (FVC), first second expiratory volume (FEV 1 ), FEV 1 /FVC, peak expiratory flow (PEF), maximal mid expiratory flow (MMEF), and forced expiratory flow rate at the x% of FVC to be exhaled (FEF x% ). Spirometric data were expressed in percentages of reference values. Results were analyzed by applying repeated measures analysis of variance. The M ± SEM of weight (before-R: 81.6 ± 2.8 kg, mid-R: 80.8 ± 2.9 kg, after-R: 81.2 ± 2.9 kg), FEV 1 (before-R: 99 ± 2%, mid-R: 98 ± 2%, after-R: 98 ± 2%), FVC (before-R: 103 ± 2%, mid-R: 101 ± 2%, after-R: 101 ± 2%), PEF (before-R: 112 ± 3%, mid-R: 113 ± 2%, after-R: 114 ± 3%), MMEF (before-R: 83 ± 3%, mid-R: 83 ± 3%, after-R: 82 ± 3%), FEF 25% (before-R: 90 ± 5%, mid-R: 89 ± 6%, after-R: 87 ± 6%), FEF 50% (before-R: 94 ± 4%, mid-R: 91 ± 4%, after-R: 93 ± 3%), and FEF 75% (before-R: 108 ± 3%, mid-R: 111 ± 2%, after-R:111 ± 3%) were not significantly influenced by RF. To conclude, RF did not bring about any significant changes in the spirometric values of nonsmoking healthy adult males.

  6. Effect of gas cooking on lung function in adolescents: modifying role of sex and immunoglobulin E.

    PubMed

    Corbo, G M; Forastiere, F; Agabiti, N; Dell'Orco, V; Pistelli, R; Aebischer, M L; Valente, S; Perucci, C A

    2001-07-01

    A study was undertaken to investigate the effect of gas cooking on the lung function of adolescents while considering serum IgE level as a possible effect modifier. The cross sectional study was performed in 702 subjects aged 11-13 years from primary and secondary schools in Civitavecchia and Viterbo ( Latium region in Central Italy), categorised according to how often they were in the kitchen while the mother cooked (never, sometimes, often). Data were collected by questionnaire and lung function was measured by spirometric tests. Bronchial hyperresponsiveness was evaluated by the methacholine test, atopic status by a skin prick test, and a blood sample was collected to determine serum IgE levels. The results were analysed separately for boys and girls. Multiple regression analysis was performed, taking functional parameters (FEV(1), FEV(1)/FVC, FEF(25-75), FEF(50), FEF(75)) as the dependent variables and age, height, parental smoking, and father's education as independent variables. There was no association between time spent in the kitchen and lung function level in boys, but a reduction in lung function was detected in girls which was statistically significant for FEF(75) (sometimes -10.3%, often -11.1%). After stratifying boys and girls into four groups on the basis of the IgE serum level (below and above the median value of IgE), the reduction in lung function was significant in girls with a high IgE value whereas no significant deleterious effects were evident in girls with a low IgE value or in boys with either a low or high IgE. The results remained substantially unchanged after excluding girls with a response to methacholine below the concentration of 4 mg/ml, asthmatic patients, and those with positive skin prick tests. Gas cooking has a harmful effect on the lung function of girls with a high serum level of IgE. We do not know whether serum IgE, a marker of allergic susceptibility, is a simple indicator that an inflammatory process is in progress or whether it is involved in the pathogenesis of injury leading to bronchial obstruction.

  7. Late-onset septicemia in a Norwegian national cohort of extremely premature infants receiving very early full human milk feeding.

    PubMed

    Rønnestad, Arild; Abrahamsen, Tore G; Medbø, Sverre; Reigstad, Hallvard; Lossius, Kristin; Kaaresen, Per I; Egeland, Thore; Engelund, Inger E; Irgens, Lorentz M; Markestad, Trond

    2005-03-01

    To investigate the occurrence of and risk factors for late-onset septicemia (LOS) in a national cohort of extremely premature infants who received very early full human milk feeding. A prospective study of all infants born in Norway in 1999 and 2000 with gestational age of <28 weeks or birth weight of <1000 g was performed. Extensive clinical information, including data on feeding practices and episodes of septicemia, was collected on predefined forms. LOS was defined as growth of bacteria or fungi in blood cultures in conjunction with clinical symptoms consistent with systemic infection occurring after day 6 of life. Cox regression models, including models allowing for time-dependent covariates, were applied in the analysis of LOS. Of 464 eligible infants, 462 (99.6%) were enrolled and 405 (87.7%) survived until day 7. LOS was diagnosed for 80 (19.7%). The predominant pathogens were coagulase-negative staphylococci, followed by Candida spp. Case fatality rates associated with septicemia were 10% in general and 43% for Candida spp septicemia. Necrotizing enterocolitis or bowel perforation was diagnosed for 19 infants (4%). Enteral feeding with human milk was initiated within the third day for 98% of patients, and 92% were receiving full enteral feeding (FEF) with human milk within the third week. Both high Clinical Risk Index for Babies scores and an umbilical venous catheter in situ at 7 days of age significantly predicted LOS. However, the overall most influential risk factor for LOS was the number of days without establishment of FEF with human milk, with an adjusted relative risk of 3.7 (2.0-6.9) for LOS if FEF was not established within the second week of life. The incidence and case fatality rate of septicemia for this cohort of extremely preterm infants were lower than values in comparable studies. The main difference, compared with other studies, was the feeding practice, and the data suggest that very early FEF with human milk significantly reduces the risk of LOS among extremely premature infants.

  8. Visual field recovery after vision restoration therapy (VRT) is independent of eye movements: an eye tracker study.

    PubMed

    Kasten, Erich; Bunzenthal, Ulrike; Sabel, Bernhard A

    2006-11-25

    It has been argued that patients with visual field defects compensate for their deficit by making more frequent eye movements toward the hemianopic field and that visual field enlargements found after vision restoration therapy (VRT) may be an artefact of such eye movements. In order to determine if this was correct, we recorded eye movements in hemianopic subjects before and after VRT. Visual fields were measured in subjects with homonymous visual field defects (n=15) caused by trauma, cerebral ischemia or haemorrhage (lesion age >6 months). Visual field charts were plotted using both high-resolution perimetry (HRP) and conventional perimetry before and after a 3-month period of VRT, with eye movements being recorded with a 2D-eye tracker. This permitted quantification of eye positions and measurements of deviation from fixation. VRT lead to significant visual field enlargements as indicated by an increase of stimulus detection of 3.8% when tested using HRP and about 2.2% (OD) and 3.5% (OS) fewer misses with conventional perimetry. Eye movements were expressed as the standard deviations (S.D.) of the eye position recordings from fixation. Before VRT, the S.D. was +/-0.82 degrees horizontally and +/-1.16 degrees vertically; after VRT, it was +/-0.68 degrees and +/-1.39 degrees , respectively. A cluster analysis of the horizontal eye movements before VRT showed three types of subjects with (i) small (n=7), (ii) medium (n=7) or (iii) large fixation instability (n=1). Saccades were directed equally to the right or the left side; i.e., with no preference toward the blind hemifield. After VRT, many subjects showed a smaller variability of horizontal eye movements. Before VRT, 81.6% of the recorded eye positions were found within a range of 1 degrees horizontally from fixation, whereas after VRT, 88.3% were within that range. In the 2 degrees range, we found 94.8% before and 98.9% after VRT. Subjects moved their eyes 5 degrees or more 0.3% of the time before VRT versus 0.1% after VRT. Thus, in this study, subjects with homonymous visual field defects who were attempting to fixate a central target while their fields were being plotted, typically showed brief horizontal shifts with no preference toward or away from the blind hemifield. These eye movements were usually less than 1 degrees from fixation. Large saccades toward the blind field after VRT were very rare. VRT has no effect on either the direction or the amplitude of horizontal eye movements during visual field testing. These results argue against the theory that the visual field enlargements are artefacts induced by eye movements.

  9. Pulmonary function tests

    MedlinePlus

    ... exhale, and how quickly you exhale, spirometry can evaluate a broad range of lung diseases. In a ... expiratory volume in 1 second (FEV1) Forced expiratory flow 25% to 75% (FEF25-75) Functional residual capacity ( ...

  10. Biomechanics and Strength of Manual Wheelchair Users

    PubMed Central

    Ambrosio, Fabrisia; Boninger, Michael L; Souza, Aaron L; Fitzgerald, Shirley G; Koontz, Alicia M; Cooper, Rory A

    2005-01-01

    Background/Objective: Previous investigations have identified muscular imbalance in the shoulder as a source of pain and injury in manual wheelchair users. Our aim was to determine whether a correlation exists between strength and pushrim biomechanical variables including: tangential (motive) force (Ft), radial force (Fr), axial force (Fz), total (resultant) force (FR), fraction of effective force (FEF), and cadence. Methods: Peak isokinetic shoulder strength (flexion [FLX], extension [EXT], abduction [ABD], adduction [ADD], internal rotation [IR], and external rotation [ER]) was tested in 22 manual wheelchair users with a BioDex system for 5 repetitions at 60°/s. Subjects then propelled their own manual wheelchair at 2 speeds, 0.9 m/s (2 mph) and 1.8 m/s (4 mph), for 20 seconds, during which kinematic (OPTOTRAK) and kinetic (SMARTWHEEL) data were collected. Peak isokinetic forces in the cardinal planes were correlated with pushrim biomechanical variables. Results: All peak torque strength variables correlated significantly (P ≤ 0.05) with Ft, Fr, and FR, but were not significantly correlated with Fz, FEF, or cadence. Finally, there were no relationships found between muscle strength ratios (for example, FLX/EXT) and Ft, Fr, FR, Fz, or FEF. Conclusion: There was a correlation between strength and force imparted to the pushrim among wheelchair users; however, there was no correlation found in wheelchair propulsion or muscle imbalance. Clinicians should be aware of this, and approach strength training and training in wheelchair propulsion techniques separately. PMID:16869087

  11. Controlled Formation of Mixed Nanoscale Domains of High Capacity Fe 2O 3–FeF 3 Conversion Compounds by Direct Fluorination

    DOE PAGES

    Zhou, Hui; Ruther, Rose E.; Adcock, Jamie; ...

    2015-02-22

    In this paper, we report a direct fluorination method under fluorine gas atmosphere using a fluidized bed reactor for converting nanophase iron oxide (n-Fe 2O 3) to an electrochemically stable and higher energy density iron oxyfluoride/fluoride phase. Interestingly, no noticeable bulk iron oxyfluoride phase (FeOF) phase was observed even at fluorination temperature close to 300 °C. Instead, at fluorination temperatures below 250 °C, scanning transmission electron microscopy coupled with electron energy loss spectroscopy (STEM-EELS) and X-ray photoelectron spectroscopy (XPS) analysis showed surface fluorination with nominal composition, Fe 2O 3-xF 2x (x < 1). At fluorination temperatures of 275 °C, STEM-EELSmore » results showed porous interconnected nanodomains of FeF 3 and Fe 2O 3 coexisting within the same particle, and overall the particles become less dense after fluorination. We performed potentiometric intermittent titration and electrochemical impedance spectroscopy studies to understand the lithium diffusion (or apparent diffusion) in both the oxyfluoride and mixed phase FeF 3 + Fe 2O 3 composition, and correlate the results to their electrochemical performance. Finally and further, we analyze from a thermodynamical perspective, the observed formation of the majority fluoride phase (77% FeF 3) and the absence of the expected oxyfluoride phase based on the relative formation energies of oxide, fluoride, and oxyfluorides.« less

  12. Ammonium Fluoride Mediated Synthesis of Anhydrous Metal Fluoride-Mesoporous Carbon Nanocomposites for High-Performance Lithium Ion Battery Cathodes.

    PubMed

    Chun, Jinyoung; Jo, Changshin; Sahgong, Sunhye; Kim, Min Gyu; Lim, Eunho; Kim, Dong Hyeon; Hwang, Jongkook; Kang, Eunae; Ryu, Keun Ah; Jung, Yoon Seok; Kim, Youngsik; Lee, Jinwoo

    2016-12-28

    Metal fluorides (MF x ) are one of the most attractive cathode candidates for Li ion batteries (LIBs) due to their high conversion potentials with large capacities. However, only a limited number of synthetic methods, generally involving highly toxic or inaccessible reagents, currently exist, which has made it difficult to produce well-designed nanostructures suitable for cathodes; consequently, harnessing their potential cathodic properties has been a challenge. Herein, we report a new bottom-up synthetic method utilizing ammonium fluoride (NH 4 F) for the preparation of anhydrous MF x (CuF 2 , FeF 3 , and CoF 2 )/mesoporous carbon (MSU-F-C) nanocomposites, whereby a series of metal precursor nanoparticles preconfined in mesoporous carbon were readily converted to anhydrous MF x through simple heat treatment with NH 4 F under solventless conditions. We demonstrate the versatility, lower toxicity, and efficiency of this synthetic method and, using XRD analysis, propose a mechanism for the reaction. All MF x /MSU-F-C prepared in this study exhibited superior electrochemical performances, through conversion reactions, as the cathode for LIBs. In particular, FeF 3 /MSU-F-C maintained a capacity of 650 mAh g -1 FeF3 across 50 cycles, which is ∼90% of its initial capacity. We expect that this facile synthesis method will trigger further research into the development of various nanostructured MF x for use in energy storage and other applications.

  13. Eye-rotation-induced spatial reorganization of horizontal connections in field 17 of the cat cortex.

    PubMed

    Shkorbatova, P Yu; Alekseenko, S V

    2006-06-01

    Six cats with rotation of one or both eyes (strabismus) produced surgically in the early postnatal period demonstrated torsional deviation of the eyes by 10-20 degrees in addition to the rotation. The spatial distribution of retrograde labeled neurons in field 17 was studied by microiontophoretic administration of horseradish peroxidase into individual cortical columns in fields 17 and 18. These studies showed that rotation of the eyes increased the extent of horizontal neuronal connections in field 17 along the projection of the vertical meridian of the field of vision. It is suggested that this reorganization of neuronal connections may support functional changes compensating for eye rotation, as described in the literature.

  14. Pulmonary functions in patients with subclinical hypothyroidism.

    PubMed

    Cakmak, Gulfidan; Saler, Tayyibe; Saglam, Zuhal Aydan; Yenigun, Mustafa; Ataoglu, Esra; Demir, Tuncalp; Temiz, Levent Umit

    2011-10-01

    To determine whether alterations in pulmonary function takes place in subclinical hypothyroidism by examining the diffusion lung capacity and muscle strength of such patients. This is a descriptive study conducted in 2009 at Haseki Training and Research Hospital, Istanbul, Turkey. Hundred and twenty-six patients with subclinical hypothyroidism and 58 age and sex matched individuals were recruited. Simple spirometry tests were performed, and pulmonary diffusion capacity (DLco) and muscle strength were measured. ScH patients showed a significant reduciton of the following pulmonary function tests (% predicted value) as compared with control subjects: FVC, FEV1, FEV1%, FEF25-75, FEF25-75%, DLco, DLco/VA, Pimax, Pimax% and Pemax%. These data indicate that pulmonary functions are effected in subclinical hypothyrodism. Therefore patients with or who are at high risk of having subclinical hypothyroidism, should be subjected to evaluation of pulmonary functions with simple spirometry.

  15. Feed-related Splanchnic Oxygenation in Preterm Infants With Abnormal Antenatal Doppler Developing Gut Complications.

    PubMed

    Martini, Silvia; Aceti, Arianna; Beghetti, Isadora; Faldella, Giacomo; Corvaglia, Luigi

    2018-05-01

    Preterm infants with antenatal absent or reversed end diastolic flow (AREDF) in umbilical arteries are at major risk for gastrointestinal (GI) complications, such as necrotizing enterocolitis, intestinal perforation and feeding intolerance. Near-infrared spectroscopy provides continuous monitoring of splanchnic oxygenation (SrSO2) and may represent a useful tool to predict GI outcomes in this high-risk population. This observational, pilot study assessed feed-related SrSO2 patterns at enteral feeding introduction and full enteral feeding (FEF) achievement in twenty AREDF infants with gestational age ≤34 weeks. Enrolled infants were divided into 2 groups according to the development versus lack of GI complications. Infants developing GI complications showed significantly lower SrSO2 and increased splanchnic oxygen extraction in response to enteral feeds at both enteral feeding introduction and FEF. The potential role of these findings in predicting GI complications in AREDF preterm infants seems promising and deserves further evaluation.

  16. Bronchodilator response cut-off points and FEV 0.75 reference values for spirometry in preschoolers

    PubMed Central

    Burity, Edjane Figueiredo; Pereira, Carlos Alberto de Castro; Jones, Marcus Herbert; Sayão, Larissa Bouwman; de Andrade, Armèle Dornelas; de Britto, Murilo Carlos Amorim

    2016-01-01

    ABSTRACT Objective: To determine the cut-off points for FEV1, FEV0.75, FEV0.5, and FEF25-75% bronchodilator responses in healthy preschool children and to generate reference values for FEV0.75. Methods: This was a cross-sectional community-based study involving children 3-5 years of age. Healthy preschool children were selected by a standardized questionnaire. Spirometry was performed before and after bronchodilator use. The cut-off point of the response was defined as the 95th percentile of the change in each parameter. Results: We recruited 266 children, 160 (60%) of whom were able to perform acceptable, reproducible expiratory maneuvers before and after bronchodilator use. The mean age and height were 57.78 ± 7.86 months and 106.56 ± 6.43 cm, respectively. The success rate for FEV0.5 was 35%, 68%, and 70% in the 3-, 4-, and 5-year-olds, respectively. The 95th percentile of the change in the percentage of the predicted value in response to bronchodilator use was 11.6%, 16.0%, 8.5%, and 35.5% for FEV1, FEV0.75, FEV0.5, and FEF25-75%, respectively. Conclusions: Our results provide cut-off points for bronchodilator responsiveness for FEV1, FEV0.75, FEV0.5, and FEF25-75% in healthy preschool children. In addition, we proposed gender-specific reference equations for FEV0.75. Our findings could improve the physiological assessment of respiratory function in preschool children. PMID:27812631

  17. Exercise-induced bronchoconstriction alters airway nitric oxide exchange in a pattern distinct from spirometry.

    PubMed

    Shin, Hye-Won; Schwindt, Christina D; Aledia, Anna S; Rose-Gottron, Christine M; Larson, Jennifer K; Newcomb, Robert L; Cooper, Dan M; George, Steven C

    2006-12-01

    Exhaled nitric oxide (NO) is altered in asthmatic subjects with exercise-induced bronchoconstriction (EIB). However, the physiological interpretation of exhaled NO is limited because of its dependence on exhalation flow and the inability to distinguish completely proximal (large airway) from peripheral (small airway and alveolar) contributions. We estimated flow-independent NO exchange parameters that partition exhaled NO into proximal and peripheral contributions at baseline, postexercise challenge, and postbronchodilator administration in steroid-naive mild-intermittent asthmatic subjects with EIB (24-43 yr old, n = 9) and healthy controls (20-31 yr old, n = 9). The mean +/- SD maximum airway wall flux and airway diffusing capacity were elevated and forced expiratory flow, midexpiratory phase (FEF(25-75)), forced expiratory volume in 1 s (FEV(1)), and FEV(1)/forced vital capacity (FVC) were reduced at baseline in subjects with EIB compared with healthy controls, whereas the steady-state alveolar concentration of NO and FVC were not different. Compared with the response of healthy controls, exercise challenge significantly reduced FEV(1) (-23 +/- 15%), FEF(25-75) (-37 +/- 18%), FVC (-12 +/- 12%), FEV(1)/FVC (-13 +/- 8%), and maximum airway wall flux (-35 +/- 11%) relative to baseline in subjects with EIB, whereas bronchodilator administration only increased FEV(1) (+20 +/- 21%), FEF(25-75) (+56 +/- 41%), and FEV(1)/FVC (+13 +/- 9%). We conclude that mild-intermittent steroid-naive asthmatic subjects with EIB have altered airway NO exchange dynamics at baseline and after exercise challenge but that these changes occur by distinct mechanisms and are not correlated with alterations in spirometry.

  18. Pulmonary effects of active smoking and secondhand smoke exposure among adolescent students in Juárez, Mexico.

    PubMed

    Bird, Yelena; Staines-Orozco, Hugo

    2016-01-01

    Youth smoking trends among Latin American countries, including Mexico, are on the rise. Notably, although the high prevalence of smoking in teens has been well documented in the literature, few studies have evaluated the impact of smoking and secondhand smoke (SHS) exposure on their respiratory system. To investigate the effects of smoking and SHS exposure on the respiratory health and lung function among eighth-grade students in Juárez, Mexico. A cross-sectional study was undertaken on a sample of convenience. The study outcomes centered on evaluating 300 students' lung function by spirometry (forced expiratory volume in 1 second [FEV1], forced expiratory volume in 1 second/forced vital capacity ratio [FEV1/FVC], and forced mid-expiratory flow rate [FEF25%-75%]) and their respiratory health (smoking behavior and SHS exposure) by their self-reported responses to a standardized respiratory questionnaire. The study outcomes were compared among three distinct groups: 1) nonsmokers/nonexposed to SHS; 2) nonsmokers/exposed to SHS; and 3) smokers. The majority of the study participants were 14 years old (85%), females (54%), who attended eighth grade in a public school setting (56%). Approximately, half reported being of low socioeconomic status (49%) and nonsmokers/exposed to SHS (49%). The lung function parameters of smokers were found to be lower (FEV1 =62.88±10.25; FEV1/FVC =83.50±14.15; and FEF25%-75% =66.35±12.55) than those recorded for the nonsmokers/exposed to SHS (FEV1 =69.41±11.35; FEV1/FVC =88.75±15.75; and FEF25%-75% =78.90±14.65) and significantly reduced when compared to the nonsmokers/nonexposed to SHS (FEV1 =79.14±13.61; FEV1/FVC =94.88±21.88; and FEF25%-75% =87.36±17.02) (P<0.001). Similarly, respiratory complaints were more prevalent among smokers and those exposed to SHS when compared to nonsmokers/nonexposed to SHS. Our findings suggest that initiation of cigarette smoking and, to a lesser extent, exposure to SHS in adolescence leads to increased respiratory symptoms and reduction of pulmonary function test values. Public health initiatives that aim to prevent smoking initiation, assist in cessation, and lessen SHS exposure of adolescents need to be school-based and employed as early as middle school.

  19. Red square test for visual field screening. A sensitive and simple bedside test.

    PubMed

    Mandahl, A

    1994-12-01

    A reliable bedside test for screening of visual field defects is a valuable tool in the examination of patients with a putative disease affecting the sensory visual pathways. Conventional methods such as Donders' confrontation method, counting fingers in the visual field periphery, of two-hand confrontation are not sufficiently sensitive to detect minor but nevertheless serious visual field defects. More sensitive methods requiring only simple tools are also described. In this study, a test card with four red squares surrounding a fixation target, a black dot, with a total test area of about 11 x 12.5 degrees at a distance of 30 cm, was designed for testing experience of red colour saturation in four quadrants, red square test. The Goldmann visual field was used as reference. 125 consecutive patients with pituitary adenoma (159 eyes), craniopharyngeoma (9 eyes), meningeoma (21 eyes), vascular hemisphere lesion (40 eyes), hemisphere tumour (10 eyes) and hemisphere abscess (2 eyes) were examined. The Goldmann visual field and red square test were pathological in pituitary adenomas in 35%, in craniopharyngeomas in 44%, in meningeomas in 52% and in hemisphere tumours or abscess in 100% of the eyes. Among these, no false-normal or false-pathological tests were found. However, in vascular hemisphere disease the corresponding figures were Goldmann visual field 90% and red square test 85%. The 5% difference (4 eyes) was due to Goldmann visual field defects strictly peripheral to the central 15 degrees. These defects were easily diagnosed with two-hand confrontation and

  20. Evaluating bronchodilator response in pediatric patients with post-infectious bronchiolitis obliterans: use of different criteria for identifying airway reversibility.

    PubMed

    Mattiello, Rita; Vidal, Paula Cristina; Sarria, Edgar Enrique; Pitrez, Paulo Márcio; Stein, Renato Tetelbom; Mocelin, Helena Teresinha; Fischer, Gilberto Bueno; Jones, Marcus Herbert; Pinto, Leonardo Araújo

    2016-01-01

    Post-infectious bronchiolitis obliterans (PIBO) is a clinical entity that has been classified as constrictive, fixed obstruction of the lumen by fibrotic tissue. However, recent studies using impulse oscillometry have reported bronchodilator responses in PIBO patients. The objective of this study was to evaluate bronchodilator responses in pediatric PIBO patients, comparing different criteria to define the response. We evaluated pediatric patients diagnosed with PIBO and treated at one of two pediatric pulmonology outpatient clinics in the city of Porto Alegre, Brazil. Spirometric parameters were measured in accordance with international recommendations. We included a total of 72 pediatric PIBO patients. The mean pre- and post-bronchodilator values were clearly lower than the reference values for all parameters, especially FEF25-75%. There were post-bronchodilator improvements. When measured as mean percent increases, FEV1 and FEF25-75%, improved by 11% and 20%, respectively. However, when the absolute values were calculated, the mean FEV1 and FEF25-75% both increased by only 0.1 L. We found that age at viral aggression, a family history of asthma, and allergy had no significant effects on bronchodilator responses. Pediatric patients with PIBO have peripheral airway obstruction that is responsive to treatment but is not completely reversible with a bronchodilator. The concept of PIBO as fixed, irreversible obstruction does not seem to apply to this population. Our data suggest that airway obstruction is variable in PIBO patients, a finding that could have major clinical implications. A bronquiolite obliterante pós-infecciosa (BOPI) é uma entidade clínica que tem sido classificada como obstrução fixa e constritiva do lúmen por tecido fibrótico. Entretanto, estudos recentes utilizando oscilometria de impulso relataram resposta ao broncodilatador em pacientes com BOPI. O objetivo deste estudo foi avaliar a resposta broncodilatadora em pacientes pediátricos com BOPI, comparando critérios diferentes para a definição da resposta. Foram avaliados pacientes pediátricos com diagnóstico de BOPI tratados em um de dois ambulatórios de pneumologia pediátrica na cidade de Porto Alegre (RS). Parâmetros espirométricos foram medidos de acordo com recomendações internacionais. Foram incluídos 72 pacientes pediátricos com BOPI no estudo. As médias dos valores pré- e pós-broncodilatador foram claramente inferiores aos valores de referência para todos os parâmetros, especialmente FEF25-75%. Houve uma melhora pós-broncodilatador. Quando medidos como aumentos percentuais médios, VEF1 e FEF25-75% melhoraram em 11% e 20%, respectivamente. Entretanto, quando os valores absolutos foram calculados, as médias de VEF1 e FEF25-75% aumentaram somente em 0,1 l. Verificamos que a idade da agressão viral, história familiar de asma e alergia não tiveram efeitos significativos na resposta ao broncodilatador. Pacientes pediátricos com BOPI têm uma obstrução das vias aéreas periféricas que responde ao tratamento, mas não uma reversão completa com o broncodilatador. O conceito de BOPI como obstrução fixa e irreversível parece não se aplicar a essa população. Nossos dados sugerem que a obstrução de vias aéreas em pacientes com BOPI é variável, e esse achado pode ter importantes implicações clínicas.

  1. Automated eye blink detection and correction method for clinical MR eye imaging.

    PubMed

    Wezel, Joep; Garpebring, Anders; Webb, Andrew G; van Osch, Matthias J P; Beenakker, Jan-Willem M

    2017-07-01

    To implement an on-line monitoring system to detect eye blinks during ocular MRI using field probes, and to reacquire corrupted k-space lines by means of an automatic feedback system integrated with the MR scanner. Six healthy subjects were scanned on a 7 Tesla MRI whole-body system using a custom-built receive coil. Subjects were asked to blink multiple times during the MR-scan. The local magnetic field changes were detected with an external fluorine-based field probe which was positioned close to the eye. The eye blink produces a field shift greater than a threshold level, this was communicated in real-time to the MR system which immediately reacquired the motion-corrupted k-space lines. The uncorrected images, using the original motion-corrupted data, showed severe artifacts, whereas the corrected images, using the reacquired data, provided an image quality similar to images acquired without blinks. Field probes can successfully detect eye blinks during MRI scans. By automatically reacquiring the eye blink-corrupted data, high quality MR-images of the eye can be acquired. Magn Reson Med 78:165-171, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  2. Long-term follow-up of patients with retinitis pigmentosa (RP) receiving intraocular ciliary neurotrophic factor implants

    PubMed Central

    Birch, David G.; Bennett, Lea D.; Duncan, Jacque L.; Weleber, Richard G.; Pennesi, Mark E.

    2016-01-01

    Purpose To evaluate the long-term efficacy of ciliary neurotrophic factor delivered via an intraocular encapsulated cell implant for the treatment of retinitis pigmentosa (RP). Design Long-term follow up of a multicenter, sham-controlled study. Methods Thirty-six patients at three CNTF4 sites were randomly assigned to receive a high- or low- dose implant in one eye and sham surgery in the fellow eye. The primary endpoint (change in visual field sensitivity at 12 months) has been reported previously.1 Here we report long-term visual acuity, visual field and optical coherence tomography (OCT) outcomes in 24 patients either retaining or explanting the device at 24 months relative to sham-treated eyes. Results Eyes retaining the implant showed significantly greater visual field loss from baseline than either explanted eyes or sham eyes through 42 months. By 60 months and continuing through 96 months, visual field loss was comparable among sham-treated eyes, eyes retaining the implant and explanted eyes, as was visual acuity and OCT macular volume. Conclusions Over the short term, ciliary neurotrophic factor released continuously from an intra-vitreal implant lead to loss of total visual field sensitivity that was greater than the natural progression in the sham-treated eye. This additional loss of sensitivity related to the active implant was reversible when the implant was removed. Over the long term (60 – 96 months), there was no evidence of efficacy for visual acuity, visual field sensitivity or OCT measures of retinal structure. PMID:27457255

  3. Influence of eye rotation on peripheral eye length measurement obtained with a partial coherence interferometry instrument.

    PubMed

    Verkicharla, Pavan K; Suheimat, Marwan; Mallen, Edward A H; Atchison, David A

    2014-01-01

    The eye rotation approach for measuring peripheral eye length leads to concern about whether the rotation influences results, such as through pressure exerted by eyelids or extra-ocular muscles. This study investigated whether this approach is valid. Peripheral eye lengths were measured with a Lenstar LS 900 biometer for eye rotation and no-eye rotation conditions (head rotation for horizontal meridian and instrument rotation for vertical meridian). Measurements were made for 23 healthy young adults along the horizontal visual field (± 30°) and, for a subset of eight participants along the vertical visual field (± 25°). To investigate the influence of the duration of eye rotation, for six participants measurements were made at 0, 60, 120, 180 and 210 s after eye rotation to ± 30° along horizontal and vertical visual fields. Peripheral eye lengths were not significantly different for the conditions along the vertical meridian (F1,7 = 0.16, p = 0.71). The peripheral eye lengths for the conditions were significantly different along the horizontal meridian (F1,22 = 4.85, p = 0.04), although not at individual positions (p ≥ 0.10) and were not important. There were no apparent differences between the emmetropic and myopic groups. There was no significant change in eye length at any position after maintaining position for 210 s. Eye rotation and no-eye rotation conditions were similar for measuring peripheral eye lengths along horizontal and vertical visual field meridians at ± 30° and ± 25°, respectively. Either condition can be used to estimate retinal shape from peripheral eye lengths. © 2013 The Authors Ophthalmic & Physiological Optics © 2013 The College of Optometrists.

  4. Unilateral pigmentary retinopathy--a review of literature and case presentation.

    PubMed

    Stamate, Alina-Cristina; Burcea, Marian; Zemba, Mihail

    2016-01-01

    To report a rare case of unilateral pigmentary retinopathy and describe the clinical and visual field characteristics of this particular case. We present the case of a 30-year-old male patient with a gradual loss of the visual field on his left eye (LE) for the past 10 years, with further gradual painless loss of his central visual field in the last year, and no similar symptoms in his right eye. His past medical and ocular history were unremarkable. No family history of acquired or inherited diseases was determined. Based on the history, clinical findings, and visual field examination, the diagnosis of unilateral pigmentary retinopathy was established. Visual acuity and visual field in the left eye (LE) were severely affected, while in the right eye (RE), they were completely normal. In this case, distinct features of pigmentary retinopathy were observed only in one eye, with the fellow eye being unaffected. The diagnosis requires a long follow-up period, visual field and electrophysiological testing to rule out a delayed onset of a bilateral form of pigmentary retinopathy.

  5. Sunglasses with thick temples and frame constrict temporal visual field.

    PubMed

    Denion, Eric; Dugué, Audrey Emmanuelle; Augy, Sylvain; Coffin-Pichonnet, Sophie; Mouriaux, Frédéric

    2013-12-01

    Our aim was to compare the impact of two types of sunglasses on visual field and glare: one ("thick sunglasses") with a thick plastic frame and wide temples and one ("thin sunglasses") with a thin metal frame and thin temples. Using the Goldmann perimeter, visual field surface areas (cm²) were calculated as projections on a 30-cm virtual cupola. A V4 test object was used, from seen to unseen, in 15 healthy volunteers in the primary position of gaze ("base visual field"), then allowing eye motion ("eye motion visual field") without glasses, then with "thin sunglasses," followed by "thick sunglasses." Visual field surface area differences greater than the 14% reproducibility error of the method and having a p < 0.05 were considered significant. A glare test was done using a surgical lighting system pointed at the eye(s) at different incidence angles. No significant "base visual field" or "eye motion visual field" surface area variations were noted when comparing tests done without glasses and with the "thin sunglasses." In contrast, a 22% "eye motion visual field" surface area decrease (p < 0.001) was noted when comparing tests done without glasses and with "thick sunglasses." This decrease was most severe in the temporal quadrant (-33%; p < 0.001). All subjects reported less lateral glare with the "thick sunglasses" than with the "thin sunglasses" (p < 0.001). The better protection from lateral glare offered by "thick sunglasses" is offset by the much poorer ability to use lateral space exploration; this results in a loss of most, if not all, of the additional visual field gained through eye motion.

  6. Altitude tolerance of general aviation pilots with normal or partially impaired spirometric function.

    DOT National Transportation Integrated Search

    1977-07-01

    The altitude tolerance of 10 spirometrically impaired (SI) general aviation pilots with an average forced midexpiratory flow (FEF sub 25-75%) value of 65.1 percent was compared to that of 10 spirometrically normal (SN) pilots. Cardiorespiratory param...

  7. Pulmonary function parameters and use of bronchodilators in patients with cystic fibrosis*

    PubMed Central

    Muramatu, Lucia Harumi; Stirbulov, Roberto; Forte, Wilma Carvalho Neves

    2013-01-01

    OBJECTIVE: To analyze pulmonary function parameters and pharmacodynamic response to a bronchodilator, as well as the prescription of bronchodilators, in cystic fibrosis (CF) patients. METHODS: This was a retrospective cohort study involving patients 6-18 years of age, diagnosed with CF, and followed at a referral center between 2008 and 2010. We evaluated only those patients who were able to perform pulmonary function tests (PFTs). We analyzed FVC, FEV1, and FEF25-75%, expressed as percentages of the predicted values, prior to and after bronchodilator tests (pre-BD and post-BD, respectively), in 312 PFTs. Repeated measures ANOVA and multiple comparisons were used. RESULTS: The study included 56 patients, divided into two groups: those whose PFT results spanned the 2008-2010 period (n = 37); and those whose PFT results spanned only the 2009-2010 period (n = 19). In the 2008-2010 group, there were significant reductions in post-BD FEV1 between 2008 and 2010 (p = 0.028) and between 2009 and 2010 (p = 0.036), as was also the case for pre-BD and post-BD FEF25 75% in all multiple comparisons (2008 vs. 2009; 2008 vs. 2010; and 2009 vs. 2010). In the 2009-2010 group, there were no significant differences between any of the years for any of the variables studied. Among the 312 PFTs, significant responses to the bronchodilator occurred in only 24 (7.7%), all of which were from patients for whom no bronchodilator had been prescribed during the study period. CONCLUSIONS: In the CF patients studied, there was loss of pulmonary function, indicating progressive lung disease, over time. The changes were greater for FEF25-75% than for the other variables, which suggests the initial involvement of small airways. PMID:23503485

  8. [The specificity between "fei and dachang" in the lung injury of rats with ulcerative colitis].

    PubMed

    Zhu, Li; Wang, Xin-yue; Yang, Xue; Jing, Shan; Zhou, Bo; Huang, Xiu-xia; Jia, Xu

    2013-03-01

    To observe the features of bronchopulmonary lesions in ulcerative colitis (UC) rats and the specificity with Fei and Dachang, thus providing reliance for the theory of "intestinal diseases involved Fei". The UC rat model was duplicated by using rabbit intestine mucosa tissue allergenic model and TNBS-ethanol model. A normal rat group was set up as the control. The pulmonary functions [including inspiratory resistance (Ri), expiratory resistance (Re), forced vital capacity (FVC); FEV. 2/FVC, maximal voluntary ventilation (MVV), forced expiratory flow rate (FEF25% - 75%)], and indicators of liver and kidney functions [serum alanine aminotransferase (ALT), aspartate amino transferase (AST), blood urea nitrogen (BUN), and creatinine (Cr)] were detected in the two groups. The pathological changes of colon, lung, liver, and kidney were observed in the two groups. Rats in the model group in both acute and chronic stages had weight loss, mucus and loose stool. Partial rats had such symptoms as dyspnea, shortness of breath, and wheezing. Compared with the normal group, the MW, FVC, FEV0.2 and FEF25% -75% in the acute stage; Ri, Re, MVV, FVC, and FEF25% - 75% in the chronic stage all significantly decreased (P <0.05, P <0.01), and FEV0.2/FVC significantly increased in the model group (P <0.05). The pathological results showed interstitial pneumonia and pulmonary interstitial fibrosis in the model group. But the indicators of liver and kidney functions were all in the normal range. No obvious pathological change was seen in the renal and liver tissues in the two groups. UC could specifically induce bronchopulmonary lesions. Lung injury was one of UC's intestinal manifestations. The theory of "Fei and Dachang being interior-exteriorly correlated" was demonstrated from the theory of "intestinal diseases involved Fei".

  9. Hand-rim forces and gross mechanical efficiency in asynchronous and synchronous wheelchair propulsion: a comparison.

    PubMed

    Lenton, J P; van der Woude, L; Fowler, N; Nicholson, G; Tolfrey, K; Goosey-Tolfrey, V

    2014-03-01

    To compare the force application characteristics at various push frequencies of asynchronous (ASY) and synchronous (SYN) hand-rim propulsion, 8 able-bodied participants performed a separate sub-maximal exercise test on a wheelchair roller ergometer for each propulsion mode. Each test consisted of a series of 5, 4-min exercise blocks at 1.8 m · s-1 - initially at their freely chosen frequency (FCF), followed by four counter-balanced trials at 60, 80, 120 and 140% FCF. Kinetic data was obtained using a SMARTWheel, measuring forces and moments. The gross efficiency (GE) was determined as the ratio of external work done and the total energy expended. The ASY propulsion produced higher force measures for FRES, FTAN, rate of force development & FEF (P<0.05), while there was no difference in GE values (P=0.518). In pair-matched push frequencies (ASY80:SYN60, ASY100:SYN80, ASY120:SYN100 and ASY140:SYN120), ASY propulsion forces remained significantly higher (FRES, FTAN, rate of force development & FEF P<0.05), and there was no significant effect on GE (P=0.456). Both ASY and SYN propulsion demonstrate similar trends: changes in push frequency are accompanied by changes in absolute force even without changes in the gross pattern/trend of force application, FEF or GE. Matched push frequencies continue to produce significant differences in force measures but not GE. This suggests ASY propulsion is the predominant factor in force application differences. The ASY would appear to offer a kinetic disadvantage to SYN propulsion and no physiological advantage under current testing conditions. © Georg Thieme Verlag KG Stuttgart · New York.

  10. Indoor NO2 air pollution and lung function of professional cooks.

    PubMed

    Arbex, M A; Martins, L C; Pereira, L A A; Negrini, F; Cardoso, A A; Melchert, W R; Arbex, R F; Saldiva, P H N; Zanobetti, A; Braga, A L F

    2007-04-01

    Studies of cooking-generated NO2 effects are rare in occupational epidemiology. In the present study, we evaluated the lung function of professional cooks exposed to NO2 in hospital kitchens. We performed spirometry in 37 cooks working in four hospital kitchens and estimated the predicted FVC, FEV1 and FEF(25-75), based on age, sex, race, weight, and height, according to Knudson standards. NO2 measurements were obtained for 4 consecutive days during 4 different periods at 20-day intervals in each kitchen. Measurements were performed inside and outside the kitchens, simultaneously using Palm diffusion tubes. A time/exposure indicator was defined as representative of the cumulative exposure of each cook. No statistically significant effect of NO2 exposure on FVC was found. Each year of work as a cook corresponded to a decrease in predicted FEV1 of 2.5% (P = 0.046) for the group as a whole. When smoking status and asthma were included in the analysis the effect of time/exposure decreased about 10% and lost statistical significance. On predicted FEF(25-75), a decrease of 3.5% (P = 0.035) was observed for the same group and the inclusion of controllers for smoking status and asthma did not affect the effects of time/exposure on pulmonary function parameter. After a 10-year period of work as cooks the participants of the study may present decreases in both predicted FEV1 and FEF(25-75) that can reach 20 and 30%, respectively. The present study showed small but statistically significant adverse effects of gas stove exposure on the lung function of professional cooks.

  11. Pervasive effects of a dominant foliar endophytic fungus on host genetic and phenotypic expression in a tropical tree

    PubMed Central

    Mejía, Luis C.; Herre, Edward A.; Sparks, Jed P.; Winter, Klaus; García, Milton N.; Van Bael, Sunshine A.; Stitt, Joseph; Shi, Zi; Zhang, Yufan; Guiltinan, Mark J.; Maximova, Siela N.

    2014-01-01

    It is increasingly recognized that macro-organisms (corals, insects, plants, vertebrates) consist of both host tissues and multiple microbial symbionts that play essential roles in their host's ecological and evolutionary success. Consequently, identifying benefits and costs of symbioses, as well as mechanisms underlying them are research priorities. All plants surveyed under natural conditions harbor foliar endophytic fungi (FEF) in their leaf tissues, often at high densities. Despite producing no visible effects on their hosts, experiments have nonetheless shown that FEF reduce pathogen and herbivore damage. Here, combining results from three genomic, and two physiological experiments, we demonstrate pervasive genetic and phenotypic effects of the apparently asymptomatic endophytes on their hosts. Specifically, inoculation of endophyte-free (E−) Theobroma cacao leaves with Colletotrichum tropicale (E+), the dominant FEF species in healthy T. cacao, induces consistent changes in the expression of hundreds of host genes, including many with known defensive functions. Further, E+ plants exhibited increased lignin and cellulose content, reduced maximum rates of photosynthesis (Amax), and enrichment of nitrogen-15 and carbon-13 isotopes. These phenotypic changes observed in E+ plants correspond to changes in expression of specific functional genes in related pathways. Moreover, a cacao gene (Tc00g04254) highly up-regulated by C. tropicale also confers resistance to pathogen damage in the absence of endophytes or their products in host tissues. Thus, the benefits of increased pathogen resistance in E+ plants are derived in part from up-regulation of intrinsic host defense responses, and appear to be offset by potential costs including reduced photosynthesis, altered host nitrogen metabolism, and endophyte heterotrophy of host tissues. Similar effects are likely in most plant-endophyte interactions, and should be recognized in the design and interpretation of genetic and phenotypic studies of plants. PMID:25309519

  12. Benign tracheobronchial stenoses: changes in short-term and long-term pulmonary function testing after expandable metallic stent placement.

    PubMed

    Gotway, Michael B; Golden, Jeffrey A; LaBerge, Jeanne M; Webb, W Richard; Reddy, Gautham P; Wilson, Mark W; Kerlan, Robert K; Gordon, Roy L

    2002-01-01

    To determine the short- and long-term improvement in airflow dynamics in patients undergoing tracheobronchial stent placement for benign airway stenoses. Twenty-two patients underwent 34 tracheal and/or bronchial stent placement procedures for benign airway stenoses and had the results of pulmonary function tests available. Stent placement indications included bronchomalacia after lung transplantation (n = 11), postintubation stenoses (n = 6), relapsing polychondritis (n = 2), and 1 each of tracheomalacia, tracheal compression, and histoplasmosis. Six patients underwent more than one stent placement procedure (range: 2-7 procedures). The mean forced expiratory volume in one second (FEV(1) ), forced expiratory flow rate in the midportion of the forced vital capacity curve (FEF(25-75) ), forced vital capacity, and peak flow (PF) rate obtained before stent placement were compared with those immediately after stent placement and with those measurements most remote from stent placement using the paired two-tailed test. All patients reported improved respiratory function immediately after stent placement. The mean FEV(1), FEF(25-75), and PF rate improved significantly (p < 0.001, p = 0.002, and p = 0.009, respectively) after stent placement. On long-term follow-up averaging 15 months after stent placement, these parameters declined despite patients' subjective sense of improvement. Segregating the population into transplant and nontransplant airway stenosis etiologies, however, FEF(25-75) and PF rate remained significantly improved (p = 0.045, p = 0.027, respectively), over the long term for the latter. FEV increased after subsequent stent placements for patients receiving multiple stents. Stent placement for benign tracheobronchial stenoses provides significant immediate improvement in airflow dynamics. Long-term improvement in airflow obstruction may be expected, and additional stent placements may further improve pulmonary function.

  13. Development of reference equations for spirometry in Japanese children aged 6-18 years.

    PubMed

    Takase, Masato; Sakata, Hiroshi; Shikada, Masahiro; Tatara, Katsuyoshi; Fukushima, Takayoshi; Miyakawa, Tomoo

    2013-01-01

    Spirometry is the most widely used pulmonary function test and the measured values of spirometric parameters need to be evaluated using reference values predicted for the corresponding race, sex, age, and height. However, none of the existing reference equations for Japanese children covers the entire age range of 6-18 years. The Japanese Society of Pediatric Pulmonology had organized a working group in 2006, in order to develop a new set of national standard reference equations for commonly used spirometric parameters that are applicable through the age range of 6-18 years. Quality assured spirometric data were collected through 2006-2008, from 14 institutions in Japan. We applied multiple regression analysis, using age in years (A), square of age (A(2)), height in meters (H), square of height (H(2)), and the product of age and height (AH) as explanatory variables to predict forced vital capacity (FVC), forced expiratory volume in 1 sec (FEV(1)), peak expiratory flow (PEF), forced expiratory flow between 25% and 75% of the FVC (FEF(25-75%)), instantaneous forced expiratory flow when 50% (FEF(50%)) or 75% (FEF(75%)) of the FVC have been expired. Finally, 1,296 tests (674 boys, 622 girls) formed the reference data set. Distributions of the percent predicted values did not differ by ages, confirming excellent fit of the prediction equations throughout the entire age range from 6 to 18 years. Cut-off values (around 5 percentile points) for the parameters were also determined. We recommend the use of this new set of prediction equations together with suggested cut-off values, for assessment of spirometry in Japanese children and adolescents. Copyright © 2012 Wiley Periodicals, Inc.

  14. LONG TERM EFFECTS OF PRENATAL AND POSTNATAL AIRBORNE PAH EXPOSURE ON VENTILATORY LUNG FUNCTION OF NON-ASTHMATIC PREADOLESCENT CHILDREN. PROSPECTIVE BIRTH COHORT STUDY IN KRAKOW

    PubMed Central

    Jedrychowski, Wieslaw A.; Perera, Frederica P.; Maugeri, Umberto; Majewska, Renata; Mroz, Elzbieta; Flak, Elzbieta; Camman, David; Sowa, Agata; Jacek, Ryszard

    2014-01-01

    The main goal of the study was to test the hypothesis that prenatal and postnatal exposure to polycyclic aromatic hydrocarbons (PAH) is associated with depressed lung function in non-asthmatic children. The study sample comprises 195 non-asthmatic children of non-smoking mothers, among whom the prenatal PAH exposure was assessed by personal air monitoring in pregnancy. At the age of 3, residential air monitoring was carried out to evaluate the residential PAH exposure indoors and outdoors. At the age of 5 to 8, children were given allergic skin tests for indoor allergens; and between 5–9 years lung function testing (FVC, FEV05, FEV1 and FEF25–75) was performed. The effects of prenatal PAH exposure on lung function tests repeated over the follow-up were adjusted in the General Estimated Equation (GEE) model for the relevant covariates. No association between FVC with prenatal PAH exposure was found; however for the FEV1 deficit associated with higher prenatal PAH exposure (above 37ng/m3) amounted to 53 mL (p = 0.050) and the deficit of FEF25–75 reached 164 mL (p=0.013). The corresponding deficits related to postnatal residential indoor PAH level (above 42 ng/m3) were 59 mL of FEV1 (p=0.028) and 140 mL of FEF25–75 (p=0.031). At the higher residential outdoor PAH level (above 90 ng/m3) slightly greater deficit of FEV1 (71mL, p = 0.009) was observed. The results of the study suggest that transplacental exposure to PAH compromises the normal developmental process of respiratory airways and that this effect is compounded by postnatal PAH exposure. PMID:25300014

  15. Learning a New Selection Rule in Visual and Frontal Cortex.

    PubMed

    van der Togt, Chris; Stănişor, Liviu; Pooresmaeili, Arezoo; Albantakis, Larissa; Deco, Gustavo; Roelfsema, Pieter R

    2016-08-01

    How do you make a decision if you do not know the rules of the game? Models of sensory decision-making suggest that choices are slow if evidence is weak, but they may only apply if the subject knows the task rules. Here, we asked how the learning of a new rule influences neuronal activity in the visual (area V1) and frontal cortex (area FEF) of monkeys. We devised a new icon-selection task. On each day, the monkeys saw 2 new icons (small pictures) and learned which one was relevant. We rewarded eye movements to a saccade target connected to the relevant icon with a curve. Neurons in visual and frontal cortex coded the monkey's choice, because the representation of the selected curve was enhanced. Learning delayed the neuronal selection signals and we uncovered the cause of this delay in V1, where learning to select the relevant icon caused an early suppression of surrounding image elements. These results demonstrate that the learning of a new rule causes a transition from fast and random decisions to a more considerate strategy that takes additional time and they reveal the contribution of visual and frontal cortex to the learning process. © The Author 2016. Published by Oxford University Press.

  16. Albertian errors in head-mounted displays: I. Choice of eye-point location for a near- or far-field task visualization.

    PubMed

    Rolland, Jannick; Ha, Yonggang; Fidopiastis, Cali

    2004-06-01

    A theoretical investigation of rendered depth and angular errors, or Albertian errors, linked to natural eye movements in binocular head-mounted displays (HMDs) is presented for three possible eye-point locations: the center of the entrance pupil, the nodal point, and the center of rotation of the eye. A numerical quantification was conducted for both the pupil and the center of rotation of the eye under the assumption that the user will operate solely in either the near field under an associated instrumentation setting or the far field under a different setting. Under these conditions, the eyes are taken to gaze in the plane of the stereoscopic images. Across conditions, results show that the center of the entrance pupil minimizes rendered angular errors, while the center of rotation minimizes rendered position errors. Significantly, this investigation quantifies that under proper setting of the HMD and correct choice of the eye points, rendered depth and angular errors can be brought to be either negligible or within specification of even the most stringent applications in performance of tasks in either the near field or the far field.

  17. Visual field defects of the contralateral eye of non-arteritic ischemic anterior optic neuropathy: are they related to sleep apnea?

    PubMed

    Aptel, Florent; Aryal-Charles, Nischal; Tamisier, Renaud; Pépin, Jean-Louis; Lesoin, Antoine; Chiquet, Christophe

    2017-06-01

    To evaluate whether obstructive sleep apnea (OSA) is responsible for the visual field defects found in the fellow eyes of patients with non-arteritic ischemic optic neuropathy (NAION). Prospective cross-sectional study. The visual fields of the fellow eyes of NAION subjects with OSA were compared to the visual fields of control OSA patients matched for OSA severity. All patients underwent comprehensive ophthalmological and general examination including Humphrey 24.2 SITA-Standard visual field and polysomnography. Visual field defects were classified according the Ischemic Optic Neuropathy Decompression Trial (IONDT) classification. From a cohort of 78 consecutive subjects with NAION, 34 unaffected fellow eyes were compared to 34 control eyes of subjects matched for OSA severity (apnea-hypopnea index [AHI] 35.5 ± 11.6 vs 35.4 ± 9.4 events per hour, respectively, p = 0.63). After adjustment for age and body mass index, all visual field parameters were significantly different between the NAION fellow eyes and those of the control OSA groups, including mean deviation (-4.5 ± 3.7 vs -1.3 ± 1.8 dB, respectively, p < 0.05), visual field index (91.6 ± 10 vs 97.4 ± 3.5%, respectively, p = 0.002), pattern standard deviation (3.7 ± 2.3 vs 2.5 ± 2 dB, respectively, p = 0.015), and number of subjects with at least one defect on the IONDT classification (20 vs 10, respectively, p < 0.05). OSA alone does not explain the visual field defects frequently found in the fellow eyes of NAION patients.

  18. Asymmetries and Visual Field Summaries as Predictors of Glaucoma in the Ocular Hypertension Treatment Study

    PubMed Central

    Levine, Richard A.; Demirel, Shaban; Fan, Juanjuan; Keltner, John L.; Johnson, Chris A.; Kass, Michael A.

    2007-01-01

    Purpose To evaluate whether baseline visual field data and asymmetries between eyes predict the onset of primary open-angle glaucoma (POAG) in Ocular Hypertension Treatment Study (OHTS) participants. Methods A new index, mean prognosis (MP), was designed for optimal combination of visual field thresholds, to discriminate between eyes that developed POAG from eyes that did not. Baseline intraocular pressure (IOP) in fellow eyes was used to construct measures of IOP asymmetry. Age-adjusted baseline thresholds were used to develop indicators of visual field asymmetry and summary measures of visual field defects. Marginal multivariate failure time models were constructed that relate the new index MP, IOP asymmetry, and visual field asymmetry to POAG onset for OHTS participants. Results The marginal multivariate failure time analysis showed that the MP index is significantly related to POAG onset (P < 0.0001) and appears to be a more highly significant predictor of POAG onset than either mean deviation (MD; P = 0.17) or pattern standard deviation (PSD; P = 0.046). A 1-mm Hg increase in IOP asymmetry between fellow eyes is associated with a 17% increase in risk for development of POAG. When threshold asymmetry between eyes existed, the eye with lower thresholds was at a 37% greater risk of development of POAG, and this feature was more predictive of POAG onset than the visual field index MD, though not as strong a predictor as PSD. Conclusions The MP index, IOP asymmetry, and binocular test point asymmetry can assist in clinical evaluation of eyes at risk of development of POAG. PMID:16936102

  19. Spirometric measurements and physical efficiency in children and adolescents with hearing and visual impairments.

    PubMed

    Zebrowska, A; Gawlik, K; Zwierzchowska, A

    2007-11-01

    The objective of the study was to investigate whether a sensory impairment has an effect on functional capabilities of the respiratory system and whether possible deviations from reference ranges of selected parameters might indicate a decrease of physical efficiency. Vital capacity (VC), forced vital capacity (FVC), forced expiratory volume in 1 second (FEV1), peak expiratory flow (PEF), forced expiratory flow of 25-75% (FEF25-75), maximum voluntary volume (MVV), and maximum oxygen uptake VO2 max were measured in 86 deaf and 102 blind children and adolescents, and in a matched group of hearing controls. We found a significant influence of deafness on PEF (P<0.01), FEF25-75 (P<0.05), and MVV (P<0.05). As compared with the control subjects, mean VC was significantly lower in blind adolescents (P<0.05). Our results seem to suggest that both sensory defects during childhood and adolescence affect functional capabilities of the respiratory system.

  20. Depth-estimation-enabled compound eyes

    NASA Astrophysics Data System (ADS)

    Lee, Woong-Bi; Lee, Heung-No

    2018-04-01

    Most animals that have compound eyes determine object distances by using monocular cues, especially motion parallax. In artificial compound eye imaging systems inspired by natural compound eyes, object depths are typically estimated by measuring optic flow; however, this requires mechanical movement of the compound eyes or additional acquisition time. In this paper, we propose a method for estimating object depths in a monocular compound eye imaging system based on the computational compound eye (COMPU-EYE) framework. In the COMPU-EYE system, acceptance angles are considerably larger than interommatidial angles, causing overlap between the ommatidial receptive fields. In the proposed depth estimation technique, the disparities between these receptive fields are used to determine object distances. We demonstrate that the proposed depth estimation technique can estimate the distances of multiple objects.

  1. Transmembrane voltage potential controls embryonic eye patterning in Xenopus laevis

    PubMed Central

    Pai, Vaibhav P.; Aw, Sherry; Shomrat, Tal; Lemire, Joan M.; Levin, Michael

    2012-01-01

    Uncovering the molecular mechanisms of eye development is crucial for understanding the embryonic morphogenesis of complex structures, as well as for the establishment of novel biomedical approaches to address birth defects and injuries of the visual system. Here, we characterize change in transmembrane voltage potential (Vmem) as a novel biophysical signal for eye induction in Xenopus laevis. During normal embryogenesis, a striking hyperpolarization demarcates a specific cluster of cells in the anterior neural field. Depolarizing the dorsal lineages in which these cells reside results in malformed eyes. Manipulating Vmem of non-eye cells induces well-formed ectopic eyes that are morphologically and histologically similar to endogenous eyes. Remarkably, such ectopic eyes can be induced far outside the anterior neural field. A Ca2+ channel-dependent pathway transduces the Vmem signal and regulates patterning of eye field transcription factors. These data reveal a new, instructive role for membrane voltage during embryogenesis and demonstrate that Vmem is a crucial upstream signal in eye development. Learning to control bioelectric initiators of organogenesis offers significant insight into birth defects that affect the eye and might have significant implications for regenerative approaches to ocular diseases. PMID:22159581

  2. Binocular Summation and Other Forms of Non-Dominant Eye Contribution in Individuals with Strabismic Amblyopia during Habitual Viewing

    PubMed Central

    Barrett, Brendan T.; Panesar, Gurvinder K.; Scally, Andrew J.; Pacey, Ian E.

    2013-01-01

    Background Adults with amblyopia (‘lazy eye’), long-standing strabismus (ocular misalignment) or both typically do not experience visual symptoms because the signal from weaker eye is given less weight than the signal from its fellow. Here we examine the contribution of the weaker eye of individuals with strabismus and amblyopia with both eyes open and with the deviating eye in its anomalous motor position. Methodology/Results The task consisted of a blue-on-yellow detection task along a horizontal line across the central 50 degrees of the visual field. We compare the results obtained in ten individuals with strabismic amblyopia with ten visual normals. At each field location in each participant, we examined how the sensitivity exhibited under binocular conditions compared with sensitivity from four predictions, (i) a model of binocular summation, (ii) the average of the monocular sensitivities, (iii) dominant-eye sensitivity or (iv) non-dominant-eye sensitivity. The proportion of field locations for which the binocular summation model provided the best description of binocular sensitivity was similar in normals (50.6%) and amblyopes (48.2%). Average monocular sensitivity matched binocular sensitivity in 14.1% of amblyopes’ field locations compared to 8.8% of normals’. Dominant-eye sensitivity explained sensitivity at 27.1% of field locations in amblyopes but 21.2% in normals. Non-dominant-eye sensitivity explained sensitivity at 10.6% of field locations in amblyopes but 19.4% in normals. Binocular summation provided the best description of the sensitivity profile in 6/10 amblyopes compared to 7/10 of normals. In three amblyopes, dominant-eye sensitivity most closely reflected binocular sensitivity (compared to two normals) and in the remaining amblyope, binocular sensitivity approximated to an average of the monocular sensitivities. Conclusions Our results suggest a strong positive contribution in habitual viewing from the non-dominant eye in strabismic amblyopes. This is consistent with evidence from other sources that binocular mechanisms are frequently intact in strabismic and amblyopic individuals. PMID:24205005

  3. Application of a wide-field phantom eye for optical coherence tomography and reflectance imaging.

    PubMed

    Corcoran, Anthony; Muyo, Gonzalo; van Hemert, Jano; Gorman, Alistair; Harvey, Andrew R

    2015-12-15

    Optical coherence tomography (OCT) and reflectance imaging are used in clinical practice to measure the thickness and transverse dimensions of retinal features. The recent trend towards increasing the field of view (FOV) of these devices has led to an increasing significance of the optical aberrations of both the human eye and the device. We report the design, manufacture and application of the first phantom eye that reproduces the off-axis optical characteristics of the human eye, and allows the performance assessment of wide-field ophthalmic devices. We base our design and manufacture on the wide-field schematic eye, [Navarro, R. J. Opt. Soc. Am. A , 1985, 2 .] as an accurate proxy to the human eye and enable assessment of ophthalmic imaging performance for a [Formula: see text] external FOV. We used multi-material 3D-printed retinal targets to assess imaging performance of the following ophthalmic instruments: the Optos 200Tx, Heidelberg Spectralis, Zeiss FF4 fundus camera and Optos OCT SLO and use the phantom to provide an insight into some of the challenges of wide-field OCT.

  4. Application of a wide-field phantom eye for optical coherence tomography and reflectance imaging

    NASA Astrophysics Data System (ADS)

    Corcoran, Anthony; Muyo, Gonzalo; van Hemert, Jano; Gorman, Alistair; Harvey, Andrew R.

    2015-12-01

    Optical coherence tomography (OCT) and reflectance imaging are used in clinical practice to measure the thickness and transverse dimensions of retinal features. The recent trend towards increasing the field of view (FOV) of these devices has led to an increasing significance of the optical aberrations of both the human eye and the device. We report the design, manufacture and application of the first phantom eye that reproduces the off-axis optical characteristics of the human eye, and allows the performance assessment of wide-field ophthalmic devices. We base our design and manufacture on the wide-field schematic eye, [Navarro, R. J. Opt. Soc. Am. A, 1985, 2.] as an accurate proxy to the human eye and enable assessment of ophthalmic imaging performance for a ? external FOV. We used multi-material 3D-printed retinal targets to assess imaging performance of the following ophthalmic instruments: the Optos 200Tx, Heidelberg Spectralis, Zeiss FF4 fundus camera and Optos OCT SLO and use the phantom to provide an insight into some of the challenges of wide-field OCT.

  5. Emergency Fuels Technology

    DTIC Science & Technology

    1982-06-01

    starting and running in multifuel engines. D. FEF for Ground Turbine Engines Operation of the simple-cycle, gas-turbine engine is based on the Brayton or...MR R LAYNE) CAMERON STATION WASHINGTON DC 20362 ALEXANDRIA VA 22314 CDR CDR DAVID TAYLOR NAVAL SHIP R&D CTR MARINE CORPS LOGISTICS SUPPORT CODE 2830

  6. Respiratory function and immunological status in paper-recycling workers.

    PubMed

    Zuskin, E; Mustajbegovic, J; Schachter, E N; Kanceljak, B; Kern, J; Macan, J; Ebling, Z

    1998-11-01

    The respiratory function and immunological status of workers employed in the paper recycling industry were studied. The mean age of the 101 studied workers was 41 years, and the mean duration of their exposure was 17 years. A group of 87 unexposed workers of similar age, duration of employment, and smoking history was studied for the prevalence of chronic respiratory symptoms. Lung function in the paper workers was measured by recording maximum expiratory flow volume (MEFV) curves and recording forced vital capacity (FVC), 1-second forced expiratory volume (FEV1), and maximum expiratory flow rates at 50% and the last 25% of the FVC (FEF50, FEF25). Immunological studies were performed in all 101 paper workers and in 37 control workers (volunteers). These included skin-prick tests with paper-dust extracts and other nonoccupational allergens, as well as the measurement of total serum immunoglobulin E. Significantly higher prevalences of all chronic respiratory symptoms were found in paper compared with control workers (P < 0.01). The highest prevalences were found for chronic cough (36.6%), chronic phlegm (34.7%), chronic bronchitis (33.7%), sinusitis (31.7%), and dyspnea (18.8%). Occupational asthma was diagnosed in four (4.0%) of the paper workers. A logistic regression analysis performed on chronic respiratory symptoms of paper workers indicated significant effects of smoking and exposure, with the smoking effect being the most important. Multivariate analysis of lung-function parameters indicate significant effects of exposure. For paper workers, the measured FEF50 and FEF25 were significantly decreased, compared with predicted values, suggesting obstructive changes located primarily in smaller airways. Among 101 tested paper workers, 16 (15.8%) had positive skin-prick tests to at least one of the paper extracts; none of the control workers reacted to these extracts. Increased serum IgE levels were found in 21% of the paper workers and in 5% of control workers (P < 0.05). Paper workers with positive skin-prick tests to any of the paper and/or other tested extracts had higher prevalences of chronic respiratory symptoms and lower measured lung-function tests compared with predicted than did those with negative skin-prick tests, but the differences were not statistically significant. The measured concentrations of total and respirable dust in this industry were higher than those recommended by Croatian standards. Our study suggests that work in the paper-recycling industry is associated with respiratory impairment and that sensitive workers employed in this industry may be at particular risk of developing chronic respiratory abnormalities.

  7. Short-term effects of a nicotine-free e-cigarette compared to a traditional cigarette in smokers and non-smokers.

    PubMed

    Ferrari, Marco; Zanasi, Alessandro; Nardi, Elena; Morselli Labate, Antonio Maria; Ceriana, Piero; Balestrino, Antonella; Pisani, Lara; Corcione, Nadia; Nava, Stefano

    2015-10-12

    A few studies have assessed the short-term effects of low-dose nicotine e-cigarettes, while data about nicotine-free e-cigarettes (NF e-cigarettes) are scanty. Concerns have been expressed about the use of NF e-cigarettes, because of the high concentrations of propylene glycol and other compounds in the e-cigarette vapor. This laboratory-based study was aimed to compare the effects of ad libitum use of a NF e-cigarette or and a traditional cigarette for 5 min in healthy adult smokers (n = 10) and non-smokers (n = 10). The main outcome measures were pulmonary function tests, fraction of exhaled nitric oxide (FeNO) and fractional concentration of carbon monoxide (FeCO) in exhaled breath. The traditional cigarette induced statistically significant increases in FeCO in both smokers and non-smokers, while no significant changes were observed in FeNO. In non-smokers, the traditional cigarette induced a significant decrease from baseline in FEF75 (81 % ± 35 % vs 70.2 % ± 28.2 %, P = 0.013), while in smokers significant decreases were observed in FEF25 (101.3 % ± 16.4 % vs 93.5 % ± 31.7 %, P = 0.037), FEV1 (102.2 % ± 9.5 % vs 98.3 % ± 10 %, P = 0.037) and PEF (109.5 % ± 14.6 % vs 99.2 % ± 17.5 %, P = 0.009). In contrast, the only statistically significant effects induced by the NF e-cigarette in smokers were reductions in FEV1 (102.2 % ± 9.5 % vs 99.5 ± 7.6 %, P = 0.041) and FEF25 (103.4 % ± 16.4 % vs 94.2 % ± 16.2 %, P =  .014). The present study demonstrated that the specific brand of NF e-cigarette utilized did not induce any majoracute effects. In contrast, several studies have shown that both traditional cigarettes and nicotine-containing e-cigarettes have acute effects on lung function. Our study expands on previous observations on the effects of NF e-cigarettes, but also for the first time describes the changes induced by smoking one traditional cigarette in a group of never smokers. The short-term use of the specific brand of NF e-cigarette assessed in this study had no immediate adverse effects on non-smokers and only small effects on FEV1 and FEF25 in smokers. The long-term health effects of NF e-cigarette use are unknown but worthy of further investigations. Clinicaltrials.gov: NCT02102191.

  8. Mixed mold mycotoxicosis: immunological changes in humans following exposure in water-damaged buildings.

    PubMed

    Gray, Michael R; Thrasher, Jack D; Crago, Robert; Madison, Roberta A; Arnold, Linda; Campbell, Andrew W; Vojdani, Aristo

    2003-07-01

    The study described was part of a larger multicenter investigation of patients with multiple health complaints attributable to confirmed exposure to mixed-molds infestation in water-damaged buildings. The authors present data on symptoms; clinical chemistries; abnormalities in pulmonary function; alterations in T, B, and natural killer (NK) cells; the presence of autoantibodies (i.e., antinuclear autoantibodies [ANA], autoantibodies against smooth muscle [ASM], and autoantibodies against central nervous system [CNS] and peripheral nervous system [PNS] myelins). A total of 209 adults, 42.7 +/- 16 yr of age (mean +/- standard deviation), were examined and tested with (a) self-administered weighted health history and symptom questionnaires; (b) standardized physical examinations; (c) complete blood counts and blood and urine chemistries; (d) urine and fecal cultures; (e) thyroid function tests (T4, free T3); (f) pulmonary function tests (forced vital capacity [FVC], forced expiratory volume in 1 sec [FEV1.0], and forced expiratory flow at 25%, 50%, 75%, and 25-75% of FVC [FEF25, FEF50, FEF75, and FEF2(25-75)]); (g) peripheral lymphocyte phenotypes (T, B, and NK cells) and mitogenesis determinations; and (h) a 13-item autoimmune panel. The molds-exposed patients reported a greater frequency and intensity of symptoms, particularly neurological and inflammatory symptoms, when compared with controls. The percentages of exposed individuals with increased lymphocyte phenotypes were: B cells (CD20+), 75.6%; CD5+CD25+, 68.9%; CD3+CD26+, 91.2%; CD8+HLR-DR+, 62%; and CD8+CD38+, 56.6%; whereas other phenotypes were decreased: CD8+CD11b+, 15.6% and CD3-CD16+CD56+, 38.5%. Mitogenesis to phytohemagglutinin was decreased in 26.2% of the exposed patients, but only 5.9% had decreased response to concanavalin A. Abnormally high levels of ANA, ASM, and CNS myelin (immunoglobulins [Ig]G, IgM, IgA) and PNS myelin (IgG, IgM, IgA) were found; odds ratios for each were significant at 95% confidence intervals, showing an increased risk for autoimmunity. The authors conclude that exposure to mixed molds and their associated mycotoxins in water-damaged buildings leads to multiple health problems involving the CNS and the immune system, in addition to pulmonary effects and allergies. Mold exposure also initiates inflammatory processes. The authors propose the term "mixed mold mycotoxicosis" for the multisystem illness observed in these patients.

  9. Neurophysiology and Neuroanatomy of Reflexive and Volitional Saccades: Evidence from Studies of Humans

    PubMed Central

    McDowell, Jennifer E.; Dyckman, Kara A.; Austin, Benjamin; Clementz, Brett A.

    2008-01-01

    This review provides a summary of the contributions made by human functional neuroimaging studies to the understanding of neural correlates of saccadic control. The generation of simple visually-guided saccades (redirections of gaze to a visual stimulus or prosaccades) and more complex volitional saccades require similar basic neural circuitry with additional neural regions supporting requisite higher level processes. The saccadic system has been studied extensively in non-human primates (e.g. single unit recordings) and humans (e.g. lesions and neuroimaging). Considerable knowledge of this system’s functional neuroanatomy makes it useful for investigating models of cognitive control. The network involved in prosaccade generation (by definition exogenously-driven) includes subcortical (striatum, thalamus, superior colliculus, and cerebellar vermis) and cortical structures (primary visual, extrastriate, and parietal cortices, and frontal and supplementary eye fields). Activation in these regions is also observed during endogenously-driven voluntary saccades (e.g. antisaccades, ocular motor delayed response or memory saccades, predictive tracking tasks and anticipatory saccades, and saccade sequencing), all of which require complex cognitive processes like inhibition and working memory. These additional requirements are supported by changes in neural activity in basic saccade circuitry and by recruitment of additional neural regions (such as prefrontal and anterior cingulate cortices). Activity in visual cortex is modulated as a function of task demands and may predict the type of saccade to be generated, perhaps via top-down control mechanisms. Neuroimaging studies suggest two foci of activation within FEF - medial and lateral - which may correspond to volitional and reflexive demands, respectively. Future research on saccade control could usefully (i) delineate important anatomical subdivisions that underlie functional differences, (ii) evaluate functional connectivity of anatomical regions supporting saccade generation using methods such as ICA and structural equation modeling, (iii) investigate how context affects behavior and brain activity, and (iv) use multi-modal neuroimaging to maximize spatial and temporal resolution. PMID:18835656

  10. Top-Down Control of Visual Alpha Oscillations: Sources of Control Signals and Their Mechanisms of Action

    PubMed Central

    Wang, Chao; Rajagovindan, Rajasimhan; Han, Sahng-Min; Ding, Mingzhou

    2016-01-01

    Alpha oscillations (8–12 Hz) are thought to inversely correlate with cortical excitability. Goal-oriented modulation of alpha has been studied extensively. In visual spatial attention, alpha over the region of visual cortex corresponding to the attended location decreases, signifying increased excitability to facilitate the processing of impending stimuli. In contrast, in retention of verbal working memory, alpha over visual cortex increases, signifying decreased excitability to gate out stimulus input to protect the information held online from sensory interference. According to the prevailing model, this goal-oriented biasing of sensory cortex is effected by top-down control signals from frontal and parietal cortices. The present study tests and substantiates this hypothesis by (a) identifying the signals that mediate the top-down biasing influence, (b) examining whether the cortical areas issuing these signals are task-specific or task-independent, and (c) establishing the possible mechanism of the biasing action. High-density human EEG data were recorded in two experimental paradigms: a trial-by-trial cued visual spatial attention task and a modified Sternberg working memory task. Applying Granger causality to both sensor-level and source-level data we report the following findings. In covert visual spatial attention, the regions exerting top-down control over visual activity are lateralized to the right hemisphere, with the dipoles located at the right frontal eye field (FEF) and the right inferior frontal gyrus (IFG) being the main sources of top-down influences. During retention of verbal working memory, the regions exerting top-down control over visual activity are lateralized to the left hemisphere, with the dipoles located at the left middle frontal gyrus (MFG) being the main source of top-down influences. In both experiments, top-down influences are mediated by alpha oscillations, and the biasing effect is likely achieved via an inhibition-disinhibition mechanism. PMID:26834601

  11. Large-Scale Brain Networks Supporting Divided Attention across Spatial Locations and Sensory Modalities

    PubMed Central

    Santangelo, Valerio

    2018-01-01

    Higher-order cognitive processes were shown to rely on the interplay between large-scale neural networks. However, brain networks involved with the capability to split attentional resource over multiple spatial locations and multiple stimuli or sensory modalities have been largely unexplored to date. Here I re-analyzed data from Santangelo et al. (2010) to explore the causal interactions between large-scale brain networks during divided attention. During fMRI scanning, participants monitored streams of visual and/or auditory stimuli in one or two spatial locations for detection of occasional targets. This design allowed comparing a condition in which participants monitored one stimulus/modality (either visual or auditory) in two spatial locations vs. a condition in which participants monitored two stimuli/modalities (both visual and auditory) in one spatial location. The analysis of the independent components (ICs) revealed that dividing attentional resources across two spatial locations necessitated a brain network involving the left ventro- and dorso-lateral prefrontal cortex plus the posterior parietal cortex, including the intraparietal sulcus (IPS) and the angular gyrus, bilaterally. The analysis of Granger causality highlighted that the activity of lateral prefrontal regions were predictive of the activity of all of the posteriors parietal nodes. By contrast, dividing attention across two sensory modalities necessitated a brain network including nodes belonging to the dorsal frontoparietal network, i.e., the bilateral frontal eye-fields (FEF) and IPS, plus nodes belonging to the salience network, i.e., the anterior cingulated cortex and the left and right anterior insular cortex (aIC). The analysis of Granger causality highlights a tight interdependence between the dorsal frontoparietal and salience nodes in trials requiring divided attention between different sensory modalities. The current findings therefore highlighted a dissociation among brain networks implicated during divided attention across spatial locations and sensory modalities, pointing out the importance of investigating effective connectivity of large-scale brain networks supporting complex behavior. PMID:29535614

  12. Large-Scale Brain Networks Supporting Divided Attention across Spatial Locations and Sensory Modalities.

    PubMed

    Santangelo, Valerio

    2018-01-01

    Higher-order cognitive processes were shown to rely on the interplay between large-scale neural networks. However, brain networks involved with the capability to split attentional resource over multiple spatial locations and multiple stimuli or sensory modalities have been largely unexplored to date. Here I re-analyzed data from Santangelo et al. (2010) to explore the causal interactions between large-scale brain networks during divided attention. During fMRI scanning, participants monitored streams of visual and/or auditory stimuli in one or two spatial locations for detection of occasional targets. This design allowed comparing a condition in which participants monitored one stimulus/modality (either visual or auditory) in two spatial locations vs. a condition in which participants monitored two stimuli/modalities (both visual and auditory) in one spatial location. The analysis of the independent components (ICs) revealed that dividing attentional resources across two spatial locations necessitated a brain network involving the left ventro- and dorso-lateral prefrontal cortex plus the posterior parietal cortex, including the intraparietal sulcus (IPS) and the angular gyrus, bilaterally. The analysis of Granger causality highlighted that the activity of lateral prefrontal regions were predictive of the activity of all of the posteriors parietal nodes. By contrast, dividing attention across two sensory modalities necessitated a brain network including nodes belonging to the dorsal frontoparietal network, i.e., the bilateral frontal eye-fields (FEF) and IPS, plus nodes belonging to the salience network, i.e., the anterior cingulated cortex and the left and right anterior insular cortex (aIC). The analysis of Granger causality highlights a tight interdependence between the dorsal frontoparietal and salience nodes in trials requiring divided attention between different sensory modalities. The current findings therefore highlighted a dissociation among brain networks implicated during divided attention across spatial locations and sensory modalities, pointing out the importance of investigating effective connectivity of large-scale brain networks supporting complex behavior.

  13. Diagnostic Ability of Wide-field Retinal Nerve Fiber Layer Maps Using Swept-Source Optical Coherence Tomography for Detection of Preperimetric and Early Perimetric Glaucoma.

    PubMed

    Lee, Won June; Na, Kyeong Ik; Kim, Young Kook; Jeoung, Jin Wook; Park, Ki Ho

    2017-06-01

    To evaluate the diagnostic ability of wide-field retinal nerve fiber layer (RNFL) maps with swept-source optical coherence tomography (SS-OCT) for detection of preperimetric (PPG) and early perimetric glaucoma (EG). One hundred eighty-four eyes, including 67 healthy eyes, 43 eyes with PPG, and 74 eyes with EG, were analyzed. Patients underwent a comprehensive ocular examination including red-free RNFL photography, visual field testing and wide-field SS-OCT scanning (DRI-OCT-1 Atlantis; Topcon, Tokyo, Japan). SS-OCT provides a wide-field RNFL thickness map and a SuperPixel map, which are composed of the RNFL deviation map of the peripapillary area and the deviation map of the composition of the ganglion cell layer with the inner plexiform layer and RNFL (GC-IPL+RNFL) in the macular area. The ability to discriminate PPG and EG from healthy eyes was assessed using sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) for all parameters and criteria provided by the wide-field SS-OCT scan. The wide-field RNFL thickness map using SS-OCT showed the highest sensitivity of PPG-diagnostic and EG-diagnostic performance compared with the other SS-OCT criteria based on the internal normative base (93.0 and 97.3%, respectively). Among the SS-OCT continuous parameters, the RFNL thickness of the 7 clock-hour, inferior and inferotemporal macular ganglion cell analyses showed the largest AUC of PPG-diagnostic and EG-diagnostic performance (AUC=0.809 to 0.865). The wide-field RNFL thickness map using SS-OCT performed well in distinguishing eyes with PPG and EG from healthy eyes. In the clinical setting, wide-field RNFL maps of SS-OCT can be useful tools for detection of early-stage glaucoma.

  14. Relationship between progression of visual field defect and intraocular pressure in primary open-angle glaucoma.

    PubMed

    Naito, Tomoko; Yoshikawa, Keiji; Mizoue, Shiro; Nanno, Mami; Kimura, Tairo; Suzumura, Hirotaka; Shiraga, Fumio

    2015-01-01

    To analyze the relationship between intraocular pressure (IOP) and the progression of visual field defects in Japanese primary open-angle glaucoma (POAG) and normal-tension glaucoma (NTG) patients. The subjects of the study were patients undergoing treatment for POAG or NTG who had performed visual field tests at least ten times with a Humphrey field analyzer (Swedish interactive thresholding algorithm standard, C30-2 program). The progression of visual field defects was defined by a significantly negative value of the mean deviation slope at the final visual field test during the follow-up period. The relationships between the progression of visual field defects and IOP, as well as other clinical factors, were retrospectively analyzed. A total of 156 eyes of 156 patients were included in the analysis. Significant progression of visual field defects was observed in 70 eyes of 70 patients (44.9%), while no significant progression was evident in 86 eyes of 86 patients (55.1%). The eyes with visual field defect progression had significantly lower baseline IOP (P<0.05), as well as significantly lower IOP reduction rate (P<0.01). The standard deviation of IOP values during follow-up was significantly greater in the eyes with visual field defect progression than in eyes without (P<0.05). Reducing IOP is thought to be useful for Japanese POAG or NTG patients to suppress the progression of visual field defects. In NTG, IOP management should take into account not only achieving the target IOP, but also minimizing the fluctuation of IOP during follow-up period.

  15. The subtlety of simple eyes: the tuning of visual fields to perceptual challenges in birds

    PubMed Central

    Martin, Graham R.

    2014-01-01

    Birds show interspecific variation both in the size of the fields of individual eyes and in the ways that these fields are brought together to produce the total visual field. Variation is found in the dimensions of all main parameters: binocular region, cyclopean field and blind areas. There is a phylogenetic signal with respect to maximum width of the binocular field in that passerine species have significantly broader field widths than non-passerines; broadest fields are found among crows (Corvidae). Among non-passerines, visual fields show considerable variation within families and even within some genera. It is argued that (i) the main drivers of differences in visual fields are associated with perceptual challenges that arise through different modes of foraging, and (ii) the primary function of binocularity in birds lies in the control of bill position rather than in the control of locomotion. The informational function of binocular vision does not lie in binocularity per se (two eyes receiving slightly different information simultaneously about the same objects from which higher-order depth information is extracted), but in the contralateral projection of the visual field of each eye. Contralateral projection ensures that each eye receives information from a symmetrically expanding optic flow-field from which direction of travel and time to contact targets can be extracted, particularly with respect to the control of bill position. PMID:24395967

  16. Multifocal visual evoked potential and automated perimetry abnormalities in strabismic amblyopes.

    PubMed

    Greenstein, Vivienne C; Eggers, Howard M; Hood, Donald C

    2008-02-01

    To compare visual field abnormalities obtained with standard automated perimetry (SAP) to those obtained with the multifocal visual evoked potential (mfVEP) technique in strabismic amblyopes. Humphrey 24-2 visual fields (HVF) and mfVEPs were obtained from each eye of 12 strabismic amblyopes. For the mfVEP, amplitudes and latencies were analyzed and probability plots were derived. Multifocal VEP and HVF hemifields were abnormal if they had clusters of two or more contiguous points at p < 0.01, or three or more contiguous points at p < 0.05 with at least one at p < 0.01. An eye was abnormal if it had an abnormal hemifield. On SAP, amblyopic eyes had significantly higher foveal thresholds (p = 0.003) and lower mean deviation values (p = 0.005) than fellow eyes. For the mfVEP, 11 amblyopic and 6 fellow eyes were abnormal. Of the 11 amblyopic eyes, 6 were abnormal on SAP. The deficits extended from the center to mid periphery. Monocular mfVEP latencies were significantly decreased for amblyopic eyes compared with control eyes (p < 0.0002). Both techniques revealed deficits in visual function across the visual field in strabismic amblyopes, but the mfVEP revealed deficits in fellow eyes and in more amblyopic eyes. In addition, mfVEP response latencies for amblyopic eyes were shorter than normal.

  17. Hawk Eyes I: Diurnal Raptors Differ in Visual Fields and Degree of Eye Movement

    PubMed Central

    O'Rourke, Colleen T.; Hall, Margaret I.; Pitlik, Todd; Fernández-Juricic, Esteban

    2010-01-01

    Background Different strategies to search and detect prey may place specific demands on sensory modalities. We studied visual field configuration, degree of eye movement, and orbit orientation in three diurnal raptors belonging to the Accipitridae and Falconidae families. Methodology/Principal Findings We used an ophthalmoscopic reflex technique and an integrated 3D digitizer system. We found inter-specific variation in visual field configuration and degree of eye movement, but not in orbit orientation. Red-tailed Hawks have relatively small binocular areas (∼33°) and wide blind areas (∼82°), but intermediate degree of eye movement (∼5°), which underscores the importance of lateral vision rather than binocular vision to scan for distant prey in open areas. Cooper's Hawks' have relatively wide binocular fields (∼36°), small blind areas (∼60°), and high degree of eye movement (∼8°), which may increase visual coverage and enhance prey detection in closed habitats. Additionally, we found that Cooper's Hawks can visually inspect the items held in the tip of the bill, which may facilitate food handling. American Kestrels have intermediate-sized binocular and lateral areas that may be used in prey detection at different distances through stereopsis and motion parallax; whereas the low degree eye movement (∼1°) may help stabilize the image when hovering above prey before an attack. Conclusions We conclude that: (a) there are between-species differences in visual field configuration in these diurnal raptors; (b) these differences are consistent with prey searching strategies and degree of visual obstruction in the environment (e.g., open and closed habitats); (c) variations in the degree of eye movement between species appear associated with foraging strategies; and (d) the size of the binocular and blind areas in hawks can vary substantially due to eye movements. Inter-specific variation in visual fields and eye movements can influence behavioral strategies to visually search for and track prey while perching. PMID:20877645

  18. Hawk eyes I: diurnal raptors differ in visual fields and degree of eye movement.

    PubMed

    O'Rourke, Colleen T; Hall, Margaret I; Pitlik, Todd; Fernández-Juricic, Esteban

    2010-09-22

    Different strategies to search and detect prey may place specific demands on sensory modalities. We studied visual field configuration, degree of eye movement, and orbit orientation in three diurnal raptors belonging to the Accipitridae and Falconidae families. We used an ophthalmoscopic reflex technique and an integrated 3D digitizer system. We found inter-specific variation in visual field configuration and degree of eye movement, but not in orbit orientation. Red-tailed Hawks have relatively small binocular areas (∼33°) and wide blind areas (∼82°), but intermediate degree of eye movement (∼5°), which underscores the importance of lateral vision rather than binocular vision to scan for distant prey in open areas. Cooper's Hawks' have relatively wide binocular fields (∼36°), small blind areas (∼60°), and high degree of eye movement (∼8°), which may increase visual coverage and enhance prey detection in closed habitats. Additionally, we found that Cooper's Hawks can visually inspect the items held in the tip of the bill, which may facilitate food handling. American Kestrels have intermediate-sized binocular and lateral areas that may be used in prey detection at different distances through stereopsis and motion parallax; whereas the low degree eye movement (∼1°) may help stabilize the image when hovering above prey before an attack. We conclude that: (a) there are between-species differences in visual field configuration in these diurnal raptors; (b) these differences are consistent with prey searching strategies and degree of visual obstruction in the environment (e.g., open and closed habitats); (c) variations in the degree of eye movement between species appear associated with foraging strategies; and (d) the size of the binocular and blind areas in hawks can vary substantially due to eye movements. Inter-specific variation in visual fields and eye movements can influence behavioral strategies to visually search for and track prey while perching.

  19. Miniature curved artificial compound eyes

    PubMed Central

    Floreano, Dario; Pericet-Camara, Ramon; Viollet, Stéphane; Ruffier, Franck; Brückner, Andreas; Leitel, Robert; Buss, Wolfgang; Menouni, Mohsine; Expert, Fabien; Juston, Raphaël; Dobrzynski, Michal Karol; L’Eplattenier, Geraud; Recktenwald, Fabian; Mallot, Hanspeter A.; Franceschini, Nicolas

    2013-01-01

    In most animal species, vision is mediated by compound eyes, which offer lower resolution than vertebrate single-lens eyes, but significantly larger fields of view with negligible distortion and spherical aberration, as well as high temporal resolution in a tiny package. Compound eyes are ideally suited for fast panoramic motion perception. Engineering a miniature artificial compound eye is challenging because it requires accurate alignment of photoreceptive and optical components on a curved surface. Here, we describe a unique design method for biomimetic compound eyes featuring a panoramic, undistorted field of view in a very thin package. The design consists of three planar layers of separately produced arrays, namely, a microlens array, a neuromorphic photodetector array, and a flexible printed circuit board that are stacked, cut, and curved to produce a mechanically flexible imager. Following this method, we have prototyped and characterized an artificial compound eye bearing a hemispherical field of view with embedded and programmable low-power signal processing, high temporal resolution, and local adaptation to illumination. The prototyped artificial compound eye possesses several characteristics similar to the eye of the fruit fly Drosophila and other arthropod species. This design method opens up additional vistas for a broad range of applications in which wide field motion detection is at a premium, such as collision-free navigation of terrestrial and aerospace vehicles, and for the experimental testing of insect vision theories. PMID:23690574

  20. Statis omnidirectional stereoscopic display system

    NASA Astrophysics Data System (ADS)

    Barton, George G.; Feldman, Sidney; Beckstead, Jeffrey A.

    1999-11-01

    A unique three camera stereoscopic omnidirectional viewing system based on the periscopic panoramic camera described in the 11/98 SPIE proceedings (AM13). The 3 panoramic cameras are equilaterally combined so each leg of the triangle approximates the human inter-ocular spacing allowing each panoramic camera to view 240 degree(s) of the panoramic scene, the most counter clockwise 120 degree(s) being the left eye field and the other 120 degree(s) segment being the right eye field. Field definition may be by green/red filtration or time discrimination of the video signal. In the first instance a 2 color spectacle is used in viewing the display or in the 2nd instance LCD goggles are used to differentiate the R/L fields. Radially scanned vidicons or re-mapped CCDs may be used. The display consists of three vertically stacked 120 degree(s) segments of the panoramic field of view with 2 fields/frame. Field A being the left eye display and Field B the right eye display.

  1. Effects of Peripheral Visual Field Loss on Eye Movements During Visual Search

    PubMed Central

    Wiecek, Emily; Pasquale, Louis R.; Fiser, Jozsef; Dakin, Steven; Bex, Peter J.

    2012-01-01

    Natural vision involves sequential eye movements that bring the fovea to locations selected by peripheral vision. How peripheral visual field loss (PVFL) affects this process is not well understood. We examine how the location and extent of PVFL affects eye movement behavior in a naturalistic visual search task. Ten patients with PVFL and 13 normally sighted subjects with full visual fields (FVF) completed 30 visual searches monocularly. Subjects located a 4° × 4° target, pseudo-randomly selected within a 26° × 11° natural image. Eye positions were recorded at 50 Hz. Search duration, fixation duration, saccade size, and number of saccades per trial were not significantly different between PVFL and FVF groups (p > 0.1). A χ2 test showed that the distributions of saccade directions for PVFL and FVL subjects were significantly different in 8 out of 10 cases (p < 0.01). Humphrey Visual Field pattern deviations for each subject were compared with the spatial distribution of eye movement directions. There were no significant correlations between saccade directional bias and visual field sensitivity across the 10 patients. Visual search performance was not significantly affected by PVFL. An analysis of eye movement directions revealed patients with PVFL show a biased directional distribution that was not directly related to the locus of vision loss, challenging feed-forward models of eye movement control. Consequently, many patients do not optimally compensate for visual field loss during visual search. PMID:23162511

  2. Multiconjugate adaptive optics applied to an anatomically accurate human eye model.

    PubMed

    Bedggood, P A; Ashman, R; Smith, G; Metha, A B

    2006-09-04

    Aberrations of both astronomical telescopes and the human eye can be successfully corrected with conventional adaptive optics. This produces diffraction-limited imagery over a limited field of view called the isoplanatic patch. A new technique, known as multiconjugate adaptive optics, has been developed recently in astronomy to increase the size of this patch. The key is to model atmospheric turbulence as several flat, discrete layers. A human eye, however, has several curved, aspheric surfaces and a gradient index lens, complicating the task of correcting aberrations over a wide field of view. Here we utilize a computer model to determine the degree to which this technology may be applied to generate high resolution, wide-field retinal images, and discuss the considerations necessary for optimal use with the eye. The Liou and Brennan schematic eye simulates the aspheric surfaces and gradient index lens of real human eyes. We show that the size of the isoplanatic patch of the human eye is significantly increased through multiconjugate adaptive optics.

  3. Nonmydriatic ultrawide field retinal imaging compared with dilated standard 7-field 35-mm photography and retinal specialist examination for evaluation of diabetic retinopathy.

    PubMed

    Silva, Paolo S; Cavallerano, Jerry D; Sun, Jennifer K; Noble, Jason; Aiello, Lloyd M; Aiello, Lloyd Paul

    2012-09-01

    To compare nonmydriatic stereoscopic Optomap ultrawide field images with dilated stereoscopic Early Treatment Diabetic Retinopathy Study 7-standard field 35-mm color 30-degree fundus photographs (ETDRS photography) and clinical examination for determining diabetic retinopathy (DR) and diabetic macular edema (DME) severity. Single-site, prospective, comparative, instrument validation study. One hundred three diabetic patients (206 eyes) representing the full spectrum of DR severity underwent nonmydriatic ultrawide field 100-degree and 200-degree imaging, dilated ETDRS photography, and dilated fundus examination by a retina specialist. Two independent readers graded images to determine DR and DME severity. A third masked retina specialist adjudicated discrepancies. Based on ETDRS photography (n = 200), the results were as follows: no DR (n = 25 eyes [12.5%]), mild nonproliferative DR (NPDR; 47 [23.5%]), moderate NPDR (61 [30.5%]), severe NPDR (11 [5.5%]), very severe NPDR (3 [1.5%]), and proliferative DR (52 [2.5%]). One (0.5%) eye was ungradable and 6 eyes did not complete ETDRS photography. No DME was found in 114 eyes (57.0%), DME was found in 28 eyes (14.0%), and clinically significant DME was found in 47 eyes (23.5%), and 11 (5.5%) eyes were ungradable. Exact DR severity agreement between ultrawide field 100-degree imaging and ETDRS photography occurred in 84%, with agreement within 1 level in 91% (K(W) = 0.85; K = 0.79). Nonmydriatic ultrawide field images exactly matched clinical examination results for DR in 70% and were within 1 level in 93% (K(W) = 0.71; K = 0.61). Nonmydriatic ultrawide field imaging acquisition time was less than half that of dilated ETDRS photography (P < .0001). Nonmydriatic ultrawide field images compare favorably with dilated ETDRS photography and dilated fundus examination in determining DR and DME severity; however, they are acquired more rapidly. If confirmed in broader diabetic populations, nonmydriatic ultrawide field imaging may prove to be beneficial in DR evaluation in research and clinical settings. Copyright © 2012 Elsevier Inc. All rights reserved.

  4. A combined approach based on MAF analysis and AHP method to fault detection mapping: A case study from a gas field, southwest of Iran

    NASA Astrophysics Data System (ADS)

    Shakiba, Sima; Asghari, Omid; Khah, Nasser Keshavarz Faraj

    2018-01-01

    A combined geostatitical methodology based on Min/Max Auto-correlation Factor (MAF) analysis and Analytical Hierarchy Process (AHP) is presented to generate a suitable Fault Detection Map (FDM) through seismic attributes. Five seismic attributes derived from a 2D time slice obtained from data related to a gas field located in southwest of Iran are used including instantaneous amplitude, similarity, energy, frequency, and Fault Enhancement Filter (FEF). The MAF analysis is implemented to reduce dimension of input variables, and then AHP method is applied on three obtained de-correlated MAF factors as evidential layer. Three Decision Makers (DMs) are used to construct PCMs for determining weights of selected evidential layer. Finally, weights obtained by AHP were multiplied in normalized valued of each alternative (MAF layers) and the concluded weighted layers were integrated in order to prepare final FDM. Results proved that applying algorithm proposed in this study generate a map more acceptable than the each individual attribute and sharpen the non-surface discontinuities as well as enhancing continuity of detected faults.

  5. Light emission from compound eye with conformal fluorescent coating

    NASA Astrophysics Data System (ADS)

    Martín-Palma, Raúl J.; Miller, Amy E.; Pulsifer, Drew P.; Lakhtakia, Akhlesh

    2015-03-01

    Compound eyes of insects are attractive biological systems for engineered biomimicry as artificial sources of light, given their characteristic wide angular field of view. A blowfly eye was coated with a thin conformal fluorescent film, with the aim of achieving wide field-of-view emission. Experimental results showed that the coated eye emitted visible light and that the intensity showed a weaker angular dependence than a fluorescent thin film deposited on a flat surface.

  6. [The 8-year follow-up study for clinical diagnostic potentials of frequency-doubling technology perimetry for perimetrically normal eyes of open-angle glaucoma patients with unilateral visual field loss].

    PubMed

    Fan, X; Wu, L L; Xiao, G G; Ma, Z Z; Liu, F

    2018-03-11

    Objective: To analyze potentials of frequency-doubling technology perimetry (FDP) for diagnosing open-angle glaucoma (OAG) in perimetrically normal eyes of OAG patients diagnosed with standard automated perimetry (SAP) and relating factors from abnormalities on FDP to visual field loss on SAP. Methods: A prospective cohort study. Sixty-eight eyes of 68 OAG patients visiting the ophthalmic clinic of Peking University Third Hospital during November 2003 and October 2007 [32 primary open-angle glaucoma patients and 36 normal tension glaucoma patients, 32 males and 36 females, with an average age of (59±13) years] with unilateral field loss detected by SAP (Octopus101 tG2 program) were examined with the FDP N-30 threshold program (Humphrey Instruments) at baseline. Two groups, FDP positive group and FDP negative group, were divided based on the FDP results, and visual field examinations were followed by a series of SAP examinations for the perimetrically normal eyes over 8 years. During the follow-up, the difference of the converting rate of SAP tests between the two groups was analyzed. Differences between "convertors" and "non-convertors" of SAP tests in the FDP positive group, such as the cup-to-disk ratio and glaucomatous optic neuropathy rate, were also compared with the independent-sample t test or Wilcoxon two-sample test for continuous variable data and the χ(2) test or Fisher exact test for classified variable data and rates. Results: Forty-eight perimetrically normal eyes of 48 participants had complete data and a qualifying follow-up. Baseline FDP results were positive in 33 eyes and negative in 15 eyes. Of the eyes with positive FDP results, 22 eyes developed abnormal SAP results after 4.0 to 90.0 months (median 14.5 months) , whereas none of the eyes with negative FDP results developed abnormal SAP results. For perimetrically normal eyes in the FDP positive group, "converters" showed a greater cup-to-disk ratio (0.73±0.09 vs . 0.63±0.14, Wilcoxon two-sample test, P= 0.011) and more eyes with glaucomatous optic neuropathy (19/22 vs . 4/11, Fisher exact test, P= 0.006). Conclusions: In perimetrically normal eyes of OAG patients, FDP could detect visual field loss of these eyes and predict to some extent future visual field loss on SAP. Severity of glaucomatous optic neuropathy at baseline is related to converting from abnormalities on FDP to visual field loss on SAP. (Chin J Ophthalmol, 2018, 54: 177-183) .

  7. [Possibilities of magnetotherapy in stabilization of visual function in patients with glaucoma].

    PubMed

    Bisvas Shutanto Kumar; Listopadova, N A

    1996-01-01

    Courses of magnetotherapy (MT) using ATOS device with 33 mT magnetic field induction were administered to 31 patients (43 eyes) with primary open-angle glaucoma with compensated intraocular pressure. The operation mode was intermittent, with 1.0 to 1.5 Hz field rotation frequency by 6 radii. The procedure is administered to a patient in a sitting posture with magnetic inductor held before the eye. The duration of a session is 10 min, a course consists of 10 sessions. Untreated eyes (n = 15) of the same patients were examined for control. The patients were examined before and 4 to 5 months after MT course. Vision acuity improved by 0.16 diopters, on an average, in 29 eyes (96.7%) out of 30 with vision acuity below 1.0 before treatment. Visocontrastometry was carried out using Visokontrastometer-DT device with spatial frequency range from 0.4 to 19 cycle/degree (12 frequencies) and 125 x 125 monitor. The orientation of lattices was horizontal and vertical. The contrasts ranged from 0.03 to 0.9 (12 levels). MT brought about an improvement of spatial contrast sensitivity by at least 7 values of 12 levels in 22 (84.6%) out of 26 eyes and was unchanged in 4 eyes. Visual field was examined using Humphry automated analyzer. A 120-point threshold test was used. After a course of MT, visual field deficit decreased by at least 10% in 31 (72%) out of 43 eyes, increased in 3, and was unchanged in 9 eyes; on an average, visual field deficit decreased by 22.4% vs. the initial value. After 4 to 5 months the changes in the vision acuity and visual field deficit were negligible. In controls these parameters did not appreciably change over the entire follow-up period.

  8. Specification of embryonic stem cell-derived tissues into eye fields by Wnt signaling using rostral diencephalic tissue-inducing culture.

    PubMed

    Sakakura, Eriko; Eiraku, Mototsugu; Takata, Nozomu

    2016-08-01

    The eyes are subdivided from the rostral diencephalon in early development. How the neuroectoderm regulates this subdivision, however, is largely unknown. Taking advantage of embryonic stem cell (ESC) culture using a Rax reporter line to monitor rostral diencephalon formation, we found that ESC-derived tissues at day 7 grown in Glasgow Minimum Expression Media (GMEM) containing knockout serum replacement (KSR) exhibited higher levels of expression of axin2, a Wnt target gene, than those grown in chemically defined medium (CDM). Surprisingly, Wnt agonist facilitated eye field-like tissue specification in CDM. In contrast, the addition of Wnt antagonist diminished eye field tissue formation in GMEM+KSR. Furthermore, the morphological formation of the eye tissue anlage, including the optic vesicle, was accompanied by Wnt signaling activation. Additionally, using CDM culture, we developed an efficient method for generating Rax+/Chx10+ retinal progenitors, which could become fully stratified retina. Here we provide a new avenue for exploring the mechanisms of eye field specification in vitro. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  9. [The clinical investigation of peripheral retinal changes of anterior uveitis].

    PubMed

    Guo, Chunying; Qiao, Lijun; Yang, Liu

    2015-10-01

    To observe the peripheral retinal changes of anterior uveitis patients using ultra-wide field fluorescein angiography. Retrospective case series study. Thirty-three eyes of 20 patients diagnosed as anterior uveitis from September to November 2013 in the ophthalmic clinic of Peking University First Hospital was included. All the patients underwent routine ocular examination, followed by ultra-wide field Fluorescein. There were 13 male patients and 7 female patients, aged 23-66, an average of 46 years old. The anterior uveitis recurrent in both eyes in 13 patients and only one eye in 7 patients. Uveitis duration ranging from months to 30 years. Twenty eyes were at the active stage of the anterior uveitis while 13 eyes in the quiescent stage. Peripheral retinal vessels leakage was detected in 57.6% (19/33) of the eyes, among which in eyes with active disease the rate of peripheral retinal vessels leakage was 75% (15/20), and in eyes with quiescent disease the rate was 30.8% (4/13). Optic disk hyperfluorescence was found in 6 of 20 eyes with active disease. Cystoid macular edema was found in 4 eyes. In addition, peripheral retinal hyperfluorescence dot and zone were detected in 2 eyes. Peripheral retinal vessels were detected to have inflammative leakage in patients of anterior uveitis by ultra-wide field fluorescein agiography. Peripheral retinal inflammation may still exist even in the quiescent stage of the anterior uveitis.

  10. Ocular Aberrations Across the Visual Field During Accommodation

    NASA Astrophysics Data System (ADS)

    Liu, Tao

    Myopia is classically defined as a mismatch between the optical power of the relaxed eye and its dioptric length. This definition is entirely foveocentric without concern for the contributions of peripheral refractive errors to myopia development. Long periods of steady near-work was considered to cause myopia development due to inadequate accommodation. Consequently, not only the on-axis optical features but also off-axis ones should be probed to gain insight about myopia progression. Moreover, these features need to be understood not only for the relaxed eye, but also for the accommodating eye. To acquire complete data set, a custom-built Indiana Scanning Aberrometer for Wavefront (I SAW) was developed to measure wavefront aberration along 37 line-of-sights at 8 different accommodation states in the central 30 degree visual field. We found that ocular refractive state changed uniformly over the central visual field as the eye accommodates up to 6D, and the accuracy of accommodation across the central visual field is similar to that measured in the fovea. No systematic difference between emmetropic and myopic eyes was evident. Then, a linear vector-summation rule for axial and oblique astigmatism was found to account for their interaction over the central visual field. Using this combination rule, our experimental evidence revealed no systematic effect of accommodation on axial or oblique astigmatism for two adult populations. The axial and oblique astigmatism of the whole eye is less than for the cornea alone, indicating a compensatory role for internal optics at all accommodative states. This compensation mechanism was further validated theoretically with schematic eye model. Lastly, we developed a hybrid method yielding customized eye models that accurately reproduce the empirical measurements and reasonably represent the anatomical structure, thus providing a mechanistic explanation for the changes in the eye's aberration structure that occur over the central visual field during accommodation.

  11. Assessment of Diabetic Retinopathy Using Nonmydriatic Ultra-Widefield Scanning Laser Ophthalmoscopy (Optomap) Compared With ETDRS 7-Field Stereo Photography

    PubMed Central

    Kernt, Marcus; Hadi, Indrawati; Pinter, Florian; Seidensticker, Florian; Hirneiss, Christoph; Haritoglou, Christos; Kampik, Anselm; Ulbig, Michael W.; Neubauer, Aljoscha S.

    2012-01-01

    OBJECTIVE To compare the diagnostic properties of a nonmydriatic 200° ultra-widefield scanning laser ophthalmoscope (SLO) versus mydriatic Early Treatment of Diabetic Retinopathy Study (ETDRS) 7-field photography for diabetic retinopathy (DR) screening. RESEARCH DESIGN AND METHODS A consecutive series of 212 eyes of 141 patients with different levels of DR were examined. Grading of DR and clinically significant macular edema (CSME) from mydriatic ETDRS 7-field stereo photography was compared with grading obtained by Optomap Panoramic 200 SLO images. All SLO scans were performed through an undilated pupil, and no additional clinical information was used for evaluation of all images by the two independent, masked, expert graders. RESULTS Twenty-two eyes from ETDRS 7-field photography and 12 eyes from Optomap were not gradable by at least one grader because of poor image quality. A total of 144 eyes were analyzed regarding DR level and 155 eyes regarding CSME. For ETDRS 7-field photography, 22 eyes (18 for grader 2) had no or mild DR (ETDRS levels ≤ 20) and 117 eyes (111 for grader 2) had no CSME. A highly substantial agreement between both Optomap DR and CSME grading and ETDRS 7-field photography existed with κ = 0.79 for DR and 0.73 for CSME for grader 1, and κ = 0.77 (DR) and 0.77 (CSME) for grader 2. CONCLUSIONS Determination of CSME and grading of DR level from Optomap Panoramic 200 nonmydriatic images show a positive correlation with mydriatic ETDRS 7-field stereo photography. Both techniques are of sufficient quality to assess DR and CSME. Optomap Panoramic 200 images cover a larger retinal area and therefore may offer additional diagnostic properties. PMID:22912430

  12. Assessment of diabetic retinopathy using nonmydriatic ultra-widefield scanning laser ophthalmoscopy (Optomap) compared with ETDRS 7-field stereo photography.

    PubMed

    Kernt, Marcus; Hadi, Indrawati; Pinter, Florian; Seidensticker, Florian; Hirneiss, Christoph; Haritoglou, Christos; Kampik, Anselm; Ulbig, Michael W; Neubauer, Aljoscha S

    2012-12-01

    To compare the diagnostic properties of a nonmydriatic 200° ultra-widefield scanning laser ophthalmoscope (SLO) versus mydriatic Early Treatment of Diabetic Retinopathy Study (ETDRS) 7-field photography for diabetic retinopathy (DR) screening. A consecutive series of 212 eyes of 141 patients with different levels of DR were examined. Grading of DR and clinically significant macular edema (CSME) from mydriatic ETDRS 7-field stereo photography was compared with grading obtained by Optomap Panoramic 200 SLO images. All SLO scans were performed through an undilated pupil, and no additional clinical information was used for evaluation of all images by the two independent, masked, expert graders. Twenty-two eyes from ETDRS 7-field photography and 12 eyes from Optomap were not gradable by at least one grader because of poor image quality. A total of 144 eyes were analyzed regarding DR level and 155 eyes regarding CSME. For ETDRS 7-field photography, 22 eyes (18 for grader 2) had no or mild DR (ETDRS levels ≤ 20) and 117 eyes (111 for grader 2) had no CSME. A highly substantial agreement between both Optomap DR and CSME grading and ETDRS 7-field photography existed with κ = 0.79 for DR and 0.73 for CSME for grader 1, and κ = 0.77 (DR) and 0.77 (CSME) for grader 2. Determination of CSME and grading of DR level from Optomap Panoramic 200 nonmydriatic images show a positive correlation with mydriatic ETDRS 7-field stereo photography. Both techniques are of sufficient quality to assess DR and CSME. Optomap Panoramic 200 images cover a larger retinal area and therefore may offer additional diagnostic properties.

  13. Design, simulation and evaluation of uniform magnetic field systems for head-free eye movement recordings with scleral search coils.

    PubMed

    Eibenberger, Karin; Eibenberger, Bernhard; Rucci, Michele

    2016-08-01

    The precise measurement of eye movements is important for investigating vision, oculomotor control and vestibular function. The magnetic scleral search coil technique is one of the most precise measurement techniques for recording eye movements with very high spatial (≈ 1 arcmin) and temporal (>kHz) resolution. The technique is based on measuring voltage induced in a search coil through a large magnetic field. This search coil is embedded in a contact lens worn by a human subject. The measured voltage is in direct relationship to the orientation of the eye in space. This requires a magnetic field with a high homogeneity in the center, since otherwise the field inhomogeneity would give the false impression of a rotation of the eye due to a translational movement of the head. To circumvent this problem, a bite bar typically restricts head movement to a minimum. However, the need often emerges to precisely record eye movements under natural viewing conditions. To this end, one needs a uniform magnetic field that is uniform over a large area. In this paper, we present the numerical and finite element simulations of the magnetic flux density of different coil geometries that could be used for search coil recordings. Based on the results, we built a 2.2 × 2.2 × 2.2 meter coil frame with a set of 3 × 4 coils to generate a 3D magnetic field and compared the measured flux density with our simulation results. In agreement with simulation results, the system yields a highly uniform field enabling high-resolution recordings of eye movements.

  14. Association of childhood perennial allergic rhinitis with subclinical airflow limitation.

    PubMed

    Ciprandi, G; Capasso, M

    2010-03-01

    Allergic rhinitis (AR) is a relevant risk factor for the onset of asthma, and a close association exists between the nose and the bronchi. Recently, it has been evidenced that the duration of AR and mite allergy represent high risks for spirometric impairment in allergic adults. To evaluate a group of AR children, without bronchial symptoms, to investigate spirometric impairments. Two hundred children with moderate-severe AR were consecutively evaluated. Clinical examination, skin prick test, and spirometry were performed in all children. Thirty-one percent of the children had forced expiratory flow at 25% and 75% of the pulmonary volume (FEF25-75%)<80% of the predicted values and 11% had both forced expiratory volume in 1 s and FEF25-75%<80% of the predicted values. Rhinitis duration and sensitization to house dust mites were significantly associated with impaired values of these spirometric parameters. This study highlights the close link between the upper and the lower airways and the role of some risk factors, such as long duration and mite sensitization, as early prognostic markers of bronchial involvement in children with AR and perceiving nasal symptoms alone.

  15. Associations of symptoms related to isocyanate, ureaformol, and formophenolic exposures with respiratory symptoms and lung function in coal miners

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bertrand, J.P.; Simon, V.; Chau, N.

    The respiratory effects of diphenylmethane diisocyanate (MDI)-based resins and ureaformol- and formophenolic-based resins, used in coal mining, are unknown. This cross-sectional study of 354 miners evaluated respiratory health in miners with MDI-related symptoms (IS) and ureaformol/formophenolic-related symptoms (UFS). The protocol included clinical examination, chest radiograph, questionnaire on respiratory symptoms, smoking habit, job history, resin handling, and spirometry. Resin handling concerned 27.7% of the miners. IS affected 5.6%, and 1.4% also after work. UFS affected 22.6%, and 2.3% also after work. Wheezing affected 35.6%; chronic cough, expectoration, or bronchitis about 10%; dyspnea 5.4%; and asthma 2.8%. The miners with UFS hadmore » significantly more frequent chronic cough, expectoration, chronic bronchitis, dyspnea, and wheezing, whereas those with IS at and after work had markedly lower FVC, FEV1, MMEF, FEF50% and FEF25%. These findings raise the possibility of deleterious effects of exposures to MDI and ureaformol/ ormophenolic resins on respiratory health and lung function in coal miners during their working life.« less

  16. Eye structure and amphibious foraging in albatrosses

    PubMed Central

    Martin, G. R.

    1998-01-01

    Anterior eye structure and retinal visual fields were determined in grey-headed and black-browed albatrosses, Diomedea melanophris and D. chrysostoma (Procellariiformes, Diomedeidae), using keratometry and an ophthalmoscopic reflex technique. Results for the two species were very similar and indicate that the eyes are of an amphibious optical design suggesting that albatross vision is well suited to the visual pursuit of active prey both on and below the ocean surface. The corneas are relatively flat (radius ca. 14.5 mm) and hence of low absolute refractive power (ca. 23 dioptres). In air the binocular fields are relatively long (vertical extent ca. 70 degrees) and narrow (maximum width in the plane of the optic axes 26–32 degrees), a topography found in a range of bird species that employ visual guidance of bill position when foraging. The cyclopean fields measure approximately 270 degrees in the horizontal plane, but there is a 60 degrees blind sector above the head owing to the positioning of the eyes below the protruding supraorbital ridges. Upon immersion the monocular fields decrease in width such that the binocular fields are abolished. Anterior eye structure, and visual field topography in both air and water, show marked similarity with those of the Humboldt penguin.

  17. Do the Eyes Have It? Using Eye Tracking to Assess Students Cognitive Dimensions

    ERIC Educational Resources Information Center

    Nisiforou, Efi A.; Laghos, Andrew

    2013-01-01

    Field dependence/independence (FD/FI) is a significant dimension of cognitive styles. The paper presents results of a study that seeks to identify individuals' level of field independence during visual stimulus tasks processing. Specifically, it examined the relationship between the Hidden Figure Test (HFT) scores and the eye tracking metrics.…

  18. Visual field structure in the Empress Leilia, Asterocampa leilia (Lepidoptera, Nymphalidae): dimensions and regional variation in acuity.

    PubMed

    Rutowski, Ronald L; Warrant, Eric J

    2002-02-01

    Male Empress Leilia butterflies ( Asterocampa leilia) use a sit-and-wait tactic to locate mates. To see how vision might influence male behavior, we studied the morphology, optics, and receptor physiology of their eyes and found the following. (1) Each eye's visual field is approximately hemispherical with at most a 10 degrees overlap in the fields of the eyes. There are no large sexual differences in visual field dimensions. (2) In both sexes, rhabdoms in the frontal and dorsal ommatidia are longer than those in other eye regions. (3) Interommatidial angles are smallest frontally and around the equator of the eye. Minimum interommatidial angles are 0.9-1 degrees in males and 1.3-1.4 degrees in females. (4) Acceptance angles of ommatidia closely match interommatidial angles in the frontal region of the eye. We conclude that vision in these butterflies is mostly monocular and that males have more acute vision than females, especially in the frontal region (large facets, small interommatidial angles, small acceptance angles, long rhabdoms, and a close match between interommatidial angles and acceptance angles). This study also suggests that perched males direct their most acute vision where females are likely to appear but show no eye modifications that appear clearly related to a mate-locating tactic.

  19. Vision problems

    MedlinePlus

    ... shade or curtain hanging across part of your visual field. Optic neuritis : inflammation of the optic nerve ... to ask your doctor Images Crossed eyes Eye Visual acuity test Slit-lamp exam Visual field test ...

  20. Field of Vision Influences Sensory-Motor Control of Skilled and Less-Skilled Dart Players

    PubMed Central

    Rienhoff, Rebecca; Baker, Joseph; Fischer, Lennart; Strauss, Bernd; Schorer, Jörg

    2012-01-01

    One characteristic of perceptual expertise in sport and other domains is known as ’the quiet eye', which assumes that fixated information is processed during gaze stability and insufficient spatial information leads to a decrease in performance. The aims of this study were a) replicating inter- and intra-group variability and b) investigating the extent to which quiet eye supports information pick-up of varying fields of vision (i.e., central versus peripheral) using a specific eye-tracking paradigm to compare different skill levels in a dart throwing task. Differences between skill levels were replicated at baseline, but no significant differences in throwing performance were revealed among the visual occlusion conditions. Findings are generally in line with the association between quiet eye duration and aiming performance, but raise questions regarding the relevance of central vision information pick-up for the quiet eye. Key pointsInvestigation of throwing performance and quiet eye duration in dart throwing under several vision conditionsFirst investigation using a dynamic occlusion paradigm, manipulating field of vision in situReplication of previous findings concerning throwing performance and quiet eye durationNew insights about the role of central (and peripheral) vision concerning the quiet eye phenomena PMID:24149366

  1. Detection of posterior vortex veins in eyes with pathologic myopia by ultra-widefield indocyanine green angiography.

    PubMed

    Moriyama, Muka; Cao, Kejia; Ogata, Satoko; Ohno-Matsui, Kyoko

    2017-09-01

    To analyse the characteristics of posterior vortex veins detected in highly myopic eyes by wide-field indocyanine green angiography (ICGA). One hundred and fifty-eight consecutive patients (302 eyes) with high myopia (myopic refractive error >8.0 dioptres (D) or axial length ≥26.5 mm) were studied. Wide-field ICGA was performed with the Spectralis HRA module. Posterior vortex veins were found in 80 eyes (26%). The prevalence of posterior staphyloma was significantly higher in eyes in which posterior vortex vein was detected than in eyes without posterior vortex vein. The posterior vortex veins were classified into five types according to the site of exit from the eye; around the optic nerve in 28%, in the macular area in 17%, along the border of staphyloma in 6%, along the margin of macular atrophy or large peripapillary conus in 21%, and elsewhere in 28%. In one eye, two posterior vortex veins collected the choroidal venous blood from the entire fundus. Wide-field ICGA can analyse the characteristic features of choroidal blood outflow system through posterior vortex veins in highly myopic eyes. They may play an important role as routes of choroidal outflow in highly myopic eyes. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  2. A comparison of terbutaline and fenoterol unit dose vials in treating children with acute asthmatic attacks.

    PubMed

    Lin, Yung-Zen; Huang, Fu-Yuan

    2002-01-01

    To compare the bronchodilation and adverse effects of two commercially marketed short-acting beta2-adrenergic agonists, terbutaline (Bricanyl, 5.0 mg/2ml) and fenoterol (Berotec,1.25 mg/2ml) unit dose vials (UDV), 108 acute asthmatic children, aged 5 to 14, were randomly enrolled into this study. Nebulization treatment for 10 minutes using an air compressor nebulizer was performed after measurements of baseline spirometry, SaO2, blood pressure and pulse rate. Same measurements were repeated at 0, 5, 15 and 30 minutes after the end of the nebulization treatment. The blood pressure was also monitored immediately and 30 minutes after treatment. Almost all the spirometric parameters of both treatments at various time points significantly improved. The pulse rate significantly increased at 15 and 30 min. The SaO2 significantly increased at 30 min. The systolic blood pressure significantly decreased immediately (terbutaline only) and at 30 min (fenoterol only). No significant change was found in diastolic blood pressure. When the laboratory parameters at the same time points were compared. Significant better results for fenoterol treatment were found in FEV, at 30 min (p = 0.048), PEF at 15 and 30 min (p = 0.049 and p = 0.027, respectively), FEF25-75% at 30 min (p = 0.033), mean absolute increase of PEF at 15 min (p = 0.034) and 30 min (p = 0.021), FEF25-75% at 30 min (p = 0.046), and in mean percent increase of FEF25-75% at 30 min (p = 0.047). The adverse effects for both groups were almost equal and around 21%. In conclusion, both terbutaline and fenoterol UDV nebulization treatments are effective in treating acute asthmatic children. The adverse effects are nearly equal. The fenoterol UDV nebulization treatment shows a little better result in improving pulmonary function than does terbutaline.

  3. Characterization of pulmonary function impairments in patients with mucopolysaccharidoses--changes with age and treatment.

    PubMed

    Lin, Shuan-Pei; Shih, Shou-Chuan; Chuang, Chih-Kuang; Lee, Kuo-Sheng; Chen, Ming-Ren; Niu, Dau-Ming; Chiu, Pao Chin; Lin, Shio Jean; Lin, Hsiang-Yu

    2014-03-01

    The mucopolysaccharidoses (MPS) comprise a group of inherited lysosomal storage disorders characterized by deficiencies in enzymes catalyzing the degradation of glycosaminoglycans. Impairment of pulmonary function is an important health problem for patients with MPS. However, there are few published reports on the prevalence and severity of pulmonary dysfunction in relation to age and treatment in this disorder. To evaluate pulmonary function in patients with MPS, we performed spirometry in 35 patients (22 males and 13 females; 1 with MPS I, 12 with MPS II, 16 with MPS IVA, and 6 with MPS VI; mean age, 14.6 ± 5.9 years; age range, 6.4 years to 33 years). Forced vital capacity (FVC), forced expired volume in 1 sec (FEV1), FEV1 to FVC ratio (FEV1/FVC), peak expiratory flow (PEF), and mean forced expiratory flow during the middle half of FVC (FEF25-75% ) were measured. Mean FVC, FEV1 , PEF, and FEF25-75% were 74.2%, 73.9%, 64.7%, and 37.1% of the predicted values, respectively. By spirometric classification, 32 patients (91%) had small airway disease (FEF25-75%  < 65%), 17 (48%) had restrictive lung disease, and 3 (9%) had obstructive lung disease. Percent predicted FVC, FEV1 , and PEF, as well as FEV1 /FVC, were all negatively correlated with age (P < 0.01), such that pubertal and post-pubertal patients had significantly lower values than younger patients. Of eight attenuated MPS II and VI patients who underwent follow-up pulmonary function testing after receiving enzyme replacement therapy (ERT) for 1.5-7.4 years, six showed improvements in % predicted FVC and five improved in % predicted FEV1 . Our additional characterization of the types and prevalence of pulmonary function abnormalities seen in MPS patients should be useful for clinical care. © 2013 Wiley Periodicals, Inc.

  4. Long term effects of prenatal and postnatal airborne PAH exposures on ventilatory lung function of non-asthmatic preadolescent children. Prospective birth cohort study in Krakow.

    PubMed

    Jedrychowski, Wieslaw A; Perera, Frederica P; Maugeri, Umberto; Majewska, Renata; Mroz, Elzbieta; Flak, Elzbieta; Camann, David; Sowa, Agata; Jacek, Ryszard

    2015-01-01

    The main goal of the study was to test the hypothesis that prenatal and postnatal exposures to polycyclic aromatic hydrocarbons (PAH) are associated with depressed lung function in non-asthmatic children. The study sample comprises 195 non-asthmatic children of non-smoking mothers, among whom the prenatal PAH exposure was assessed by personal air monitoring in pregnancy. At the age of 3, residential air monitoring was carried out to evaluate the residential PAH exposure indoors and outdoors. At the age of 5 to 8, children were given allergic skin tests for indoor allergens; and between 5 and 9 years lung function testing (FVC, FEV05, FEV1 and FEF25-75) was performed. The effects of prenatal PAH exposure on lung function tests repeated over the follow-up were adjusted in the General Estimated Equation (GEE) model for the relevant covariates. No association between FVC with prenatal PAH exposure was found; however for the FEV1 deficit associated with higher prenatal PAH exposure (above 37 ng/m(3)) amounted to 53 mL (p=0.050) and the deficit of FEF25-75 reached 164 mL (p=0.013). The corresponding deficits related to postnatal residential indoor PAH level (above 42 ng/m(3)) were 59 mL of FEV1 (p=0.028) and 140 mL of FEF25-75 (p=0.031). At the higher residential outdoor PAH level (above 90 ng/m(3)) slightly greater deficit of FEV1 (71 mL, p=0.009) was observed. The results of the study suggest that transplacental exposure to PAH compromises the normal developmental process of respiratory airways and that this effect is compounded by postnatal PAH exposure. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Spirometric reference values for Hopi Native American children ages 4-13 years.

    PubMed

    Arnall, David A; Nelson, Arnold G; Hearon, Christopher M; Interpreter, Christina; Kanuho, Verdell

    2016-04-01

    Spirometry is the most important tool in diagnosing pulmonary disease and is the most frequently performed pulmonary function test. Respiratory disease is also one of the greatest causes for morbidity and mortality on the Hopi Nation, but no specific reference equations exist for this unique population. The purpose of this study was to determine if population reference equations were necessary for these children and, if needed, to create new age and race-specific pulmonary nomograms for Hopi children. Two hundred and ninety-two healthy children, ages 4-13 years, attending Hopi Nation elementary schools in Arizona, were asked to perform spirometry for a full battery of pulmonary volumes and capacities of which the following were analyzed: forced vital capacity (FVC), forced expiratory volume in 1 sec (FEV1 ), FEV1 % (FEV1 /FVC), FEF25-75% and peak expiratory flow rate (PEFR). Spirometric data from Navajo children living in the same geographical region as the Hopi children were compared as well as spirometric data from common reference values used for other ethnic groups in the USA. Spirometry tests from 165 girls and 127 boys met American Thoracic Society quality control standards. We found that the natural log of height, body mass and age were significant predictors of FEV1 , FVC, and FEF25-75% in the gender-specific models and that lung function values all increased with height and age as expected. The predictions using the equations derived for Navajo, Caucasian, Mexican-American, African-American youth were significantly different (P ≤ 0.05) from the predictions derived from the Hopi equations for all of the variables across both genders, with the exceptions of Hopi versus Navajo FEV1 /FVC in the males and Hopi versus Caucasians FEF25-75% in the females. Thus it would appear for this population important to have specific formulae to provide more accurate reference values. © 2015 Wiley Periodicals, Inc.

  6. High-resolution imaging of retinal nerve fiber bundles in glaucoma using adaptive optics scanning laser ophthalmoscopy.

    PubMed

    Takayama, Kohei; Ooto, Sotaro; Hangai, Masanori; Ueda-Arakawa, Naoko; Yoshida, Sachiko; Akagi, Tadamichi; Ikeda, Hanako Ohashi; Nonaka, Atsushi; Hanebuchi, Masaaki; Inoue, Takashi; Yoshimura, Nagahisa

    2013-05-01

    To detect pathologic changes in retinal nerve fiber bundles in glaucomatous eyes seen on images obtained by adaptive optics (AO) scanning laser ophthalmoscopy (AO SLO). Prospective cross-sectional study. Twenty-eight eyes of 28 patients with open-angle glaucoma and 21 normal eyes of 21 volunteer subjects underwent a full ophthalmologic examination, visual field testing using a Humphrey Field Analyzer, fundus photography, red-free SLO imaging, spectral-domain optical coherence tomography, and imaging with an original prototype AO SLO system. The AO SLO images showed many hyperreflective bundles suggesting nerve fiber bundles. In glaucomatous eyes, the nerve fiber bundles were narrower than in normal eyes, and the nerve fiber layer thickness was correlated with the nerve fiber bundle widths on AO SLO (P < .001). In the nerve fiber layer defect area on fundus photography, the nerve fiber bundles on AO SLO were narrower compared with those in normal eyes (P < .001). At 60 degrees on the inferior temporal side of the optic disc, the nerve fiber bundle width was significantly lower, even in areas without nerve fiber layer defect, in eyes with glaucomatous eyes compared with normal eyes (P = .026). The mean deviations of each cluster in visual field testing were correlated with the corresponding nerve fiber bundle widths (P = .017). AO SLO images showed reduced nerve fiber bundle widths both in clinically normal and abnormal areas of glaucomatous eyes, and these abnormalities were associated with visual field defects, suggesting that AO SLO may be useful for detecting early nerve fiber bundle abnormalities associated with loss of visual function. Copyright © 2013 Elsevier Inc. All rights reserved.

  7. Recognizing patterns of visual field loss using unsupervised machine learning

    NASA Astrophysics Data System (ADS)

    Yousefi, Siamak; Goldbaum, Michael H.; Zangwill, Linda M.; Medeiros, Felipe A.; Bowd, Christopher

    2014-03-01

    Glaucoma is a potentially blinding optic neuropathy that results in a decrease in visual sensitivity. Visual field abnormalities (decreased visual sensitivity on psychophysical tests) are the primary means of glaucoma diagnosis. One form of visual field testing is Frequency Doubling Technology (FDT) that tests sensitivity at 52 points within the visual field. Like other psychophysical tests used in clinical practice, FDT results yield specific patterns of defect indicative of the disease. We used Gaussian Mixture Model with Expectation Maximization (GEM), (EM is used to estimate the model parameters) to automatically separate FDT data into clusters of normal and abnormal eyes. Principal component analysis (PCA) was used to decompose each cluster into different axes (patterns). FDT measurements were obtained from 1,190 eyes with normal FDT results and 786 eyes with abnormal (i.e., glaucomatous) FDT results, recruited from a university-based, longitudinal, multi-center, clinical study on glaucoma. The GEM input was the 52-point FDT threshold sensitivities for all eyes. The optimal GEM model separated the FDT fields into 3 clusters. Cluster 1 contained 94% normal fields (94% specificity) and clusters 2 and 3 combined, contained 77% abnormal fields (77% sensitivity). For clusters 1, 2 and 3 the optimal number of PCA-identified axes were 2, 2 and 5, respectively. GEM with PCA successfully separated FDT fields from healthy and glaucoma eyes and identified familiar glaucomatous patterns of loss.

  8. Evaluating Silent Reading Performance with an Eye Tracking System in Patients with Glaucoma

    PubMed Central

    Murata, Noriaki; Fukuchi, Takeo

    2017-01-01

    Objective To investigate the relationship between silent reading performance and visual field defects in patients with glaucoma using an eye tracking system. Methods Fifty glaucoma patients (Group G; mean age, 52.2 years, standard deviation: 11.4 years) and 20 normal controls (Group N; mean age, 46.9 years; standard deviation: 17.2 years) were included in the study. All participants in Group G had early to advanced glaucomatous visual field defects but better than 20/20 visual acuity in both eyes. Participants silently read Japanese articles written horizontally while the eye tracking system monitored and calculated reading duration per 100 characters, number of fixations per 100 characters, and mean fixation duration, which were compared with mean deviation and visual field index values from Humphrey visual field testing (24–2 and 10–2 Swedish interactive threshold algorithm standard) of the right versus left eye and the better versus worse eye. Results There was a statistically significant difference between Groups G and N in mean fixation duration (G, 233.4 msec; N, 215.7 msec; P = 0.010). Within Group G, significant correlations were observed between reading duration and 24–2 right mean deviation (rs = -0.280, P = 0.049), 24–2 right visual field index (rs = -0.306, P = 0.030), 24–2 worse visual field index (rs = -0.304, P = 0.032), and 10–2 worse mean deviation (rs = -0.326, P = 0.025). Significant correlations were observed between mean fixation duration and 10–2 left mean deviation (rs = -0.294, P = 0.045) and 10–2 worse mean deviation (rs = -0.306, P = 0.037), respectively. Conclusions The severity of visual field defects may influence some aspects of reading performance. At least concerning silent reading, the visual field of the worse eye is an essential element of smoothness of reading. PMID:28095478

  9. Novel wide-field x-ray optics for space

    NASA Astrophysics Data System (ADS)

    Hudec, René; Pína, Ladislav; Inneman, Adolf

    2017-11-01

    We report on the program of design and development of innovative very wide field X-ray optics for space applications. We describe the idea of wide field X-ray optics of the lobster-eye type of both Angel and Schmidt arrangements. This optics was suggested in 70ies but not yet used in space experiment due to severe manufacturing problems. The lobster-eye X-ray optics may achieve up to 180 degrees (diameter) field of view at angular resolution of order of 1 arcmin. We report on various prototypes of lobster-eye X-ray lenses based on alternative technologies (replicated double sided X-ray reflecting flats, float glass, replicated square channels etc.) as well as on their optical and X-ray tests. We also discuss the importance and performance of lobster-eye X-ray telescopes in future X-ray astronomy projects.

  10. Glaucomatous patterns in Frequency Doubling Technology (FDT) perimetry data identified by unsupervised machine learning classifiers.

    PubMed

    Bowd, Christopher; Weinreb, Robert N; Balasubramanian, Madhusudhanan; Lee, Intae; Jang, Giljin; Yousefi, Siamak; Zangwill, Linda M; Medeiros, Felipe A; Girkin, Christopher A; Liebmann, Jeffrey M; Goldbaum, Michael H

    2014-01-01

    The variational Bayesian independent component analysis-mixture model (VIM), an unsupervised machine-learning classifier, was used to automatically separate Matrix Frequency Doubling Technology (FDT) perimetry data into clusters of healthy and glaucomatous eyes, and to identify axes representing statistically independent patterns of defect in the glaucoma clusters. FDT measurements were obtained from 1,190 eyes with normal FDT results and 786 eyes with abnormal FDT results from the UCSD-based Diagnostic Innovations in Glaucoma Study (DIGS) and African Descent and Glaucoma Evaluation Study (ADAGES). For all eyes, VIM input was 52 threshold test points from the 24-2 test pattern, plus age. FDT mean deviation was -1.00 dB (S.D. = 2.80 dB) and -5.57 dB (S.D. = 5.09 dB) in FDT-normal eyes and FDT-abnormal eyes, respectively (p<0.001). VIM identified meaningful clusters of FDT data and positioned a set of statistically independent axes through the mean of each cluster. The optimal VIM model separated the FDT fields into 3 clusters. Cluster N contained primarily normal fields (1109/1190, specificity 93.1%) and clusters G1 and G2 combined, contained primarily abnormal fields (651/786, sensitivity 82.8%). For clusters G1 and G2 the optimal number of axes were 2 and 5, respectively. Patterns automatically generated along axes within the glaucoma clusters were similar to those known to be indicative of glaucoma. Fields located farther from the normal mean on each glaucoma axis showed increasing field defect severity. VIM successfully separated FDT fields from healthy and glaucoma eyes without a priori information about class membership, and identified familiar glaucomatous patterns of loss.

  11. Variable field-of-view visible and near-infrared polarization compound-eye endoscope.

    PubMed

    Kagawa, K; Shogenji, R; Tanaka, E; Yamada, K; Kawahito, S; Tanida, J

    2012-01-01

    A multi-functional compound-eye endoscope enabling variable field-of-view and polarization imaging as well as extremely deep focus is presented, which is based on a compact compound-eye camera called TOMBO (thin observation module by bound optics). Fixed and movable mirrors are introduced to control the field of view. Metal-wire-grid polarizer thin film applicable to both of visible and near-infrared lights is attached to the lenses in TOMBO and light sources. Control of the field-of-view, polarization and wavelength of the illumination realizes several observation modes such as three-dimensional shape measurement, wide field-of-view, and close-up observation of the superficial tissues and structures beneath the skin.

  12. COMPUTERIZED EXPERT SYSTEM FOR EVALUATION OF AUTOMATED VISUAL FIELDS FROM THE ISCHEMIC OPTIC NEUROPATHY DECOMPRESSION TRIAL: METHODS, BASELINE FIELDS, AND SIX-MONTH LONGITUDINAL FOLLOW-UP

    PubMed Central

    Feldon, Steven E

    2004-01-01

    ABSTRACT Purpose To validate a computerized expert system evaluating visual fields in a prospective clinical trial, the Ischemic Optic Neuropathy Decompression Trial (IONDT). To identify the pattern and within-pattern severity of field defects for study eyes at baseline and 6-month follow-up. Design Humphrey visual field (HVF) change was used as the outcome measure for a prospective, randomized, multi-center trial to test the null hypothesis that optic nerve sheath decompression was ineffective in treating nonarteritic anterior ischemic optic neuropathy and to ascertain the natural history of the disease. Methods An expert panel established criteria for the type and severity of visual field defects. Using these criteria, a rule-based computerized expert system interpreted HVF from baseline and 6-month visits for patients randomized to surgery or careful follow-up and for patients who were not randomized. Results A computerized expert system was devised and validated. The system was then used to analyze HVFs. The pattern of defects found at baseline for patients randomized to surgery did not differ from that of patients randomized to careful follow-up. The most common pattern of defect was a superior and inferior arcuate with central scotoma for randomized eyes (19.2%) and a superior and inferior arcuate for nonrandomized eyes (30.6%). Field patterns at 6 months and baseline were not different. For randomized study eyes, the superior altitudinal defects improved (P = .03), as did the inferior altitudinal defects (P = .01). For nonrandomized study eyes, only the inferior altitudinal defects improved (P = .02). No treatment effect was noted. Conclusions A novel rule-based expert system successfully interpreted visual field defects at baseline of eyes enrolled in the IONDT. PMID:15747764

  13. Inorganic nitrogen retention by watersheds at Fernow Experimental Forest and Coweeta Hydrologic Laboratory

    Treesearch

    Mary Beth Adams; Jennifer D. Knoepp; Jackson R. Webster

    2014-01-01

    Because elevated N loading can impair both terrestrial and aquatic ecosystems, understanding the abiotic and biotic controls over retention and export of dissolved inorganic N (DIN) is crucial. Long-term research has been conducted on experimental watersheds at two U.S. Forest Service experimental forests in the Appalachian region: Fernow Experimental Forest (FEF) in...

  14. Wetfall deposition and precipitation chemistry for a central Appalachian forest

    Treesearch

    Frank S. Gilliam; Mary Beth Adams

    1996-01-01

    Although extensive research on acidic deposition has been directed toward spruce-fir forests, less research has been done on the impacts of air pollution on eastern montane hardwood forests. The purpose of this study was to describe precipitation chemistry for several Appalachian hardwood forest sites at or near the Fernow Experimental Forest (FEF) to assess the...

  15. Factors influencing spatial variability in nitrogen processing in nitrogen-saturated soils

    Treesearch

    Frank S. Gilliam; Charles C. Somerville; Nikki L. Lyttle; Mary Beth Adams

    2001-01-01

    Nitrogen (N) saturation is an environmental concern for forests in the eastern U.S. Although several watersheds of the Fernow Experimental Forest (FEF), West Virginia exhibit symptoms of N saturation, many watersheds display a high degree of spatial variability in soil N processing. This study examined the effects of temperature on net N mineralization and...

  16. [Long-term efficacy of laser peripheral iridotomy in preventing progression in eyes with pigment dispersion syndrome].

    PubMed

    Qing, Guoping; Zhang, Shaodan; Wang, Huaizhou; Wang, Tao; Wang, Shuhua; Chen, Hong; Wang, Hua; Wang, Ningli

    2014-07-01

    To evaluate the long-term efficacy of laser peripheral iridotomy (LPI) in preventing deterioration in eyes with pigment dispersion syndrome (PDS). A cohort study. Nineteen patients with PDS were treated with LPI and followed up periodically in Beijing Tongren Eye Center from May 2006 to April 2007. One eye of each patient was chosen randomly for the study. Main investigating items included iris configuration, intraocular pressure (IOP), anterior chamber pigmentation, and visual field analysis. The average follow-up period was (6.5 ± 0.3) years. A paired sample t test was used to determine whether there is a significant difference between average values of pre- and post-LPI IOP and mean deviation of Humphrey visual field analysis in these PDS eyes. The average age of the 19 patients were (35.8 ± 7.1) years on admission. The initial IOP of the 19 eyes was (24.7 ± 2.2) mmHg (1 mmHg = 0.133 kPa) before LPI. The mean deviation (MD) of Humphrey visual field analysis (VFA) were (-1.82 ± 1.26) dB (-4.34--0.28 dB) . All 19 eyes had concave iris and heavy trabecular pigmentation. The iris became flat in all PDS eyes after the laser treatment. At the last follow-up visit, the average IOP was 14.8 ± 2.0 (12-20) mmHg, which was statistically lower than that of baseline (t = 11.49, P < 0.01) . Extent of trabecular pigmentation reduced obviously in 16 eyes. No deterioration or new visual field defect was detected in any of the PDS eyes. MD of the last VFA was -1.79 ± 1.21 (-4.39--0.21 dB) . There was no statistical difference between MD of the last VFA and baseline (t = -0.26, P = 0.798). The long-term follow-up results showed that LPI prevents progression effectively in eyes with PDS.

  17. Development of a novel disposable lid speculum with a drape.

    PubMed

    Urano, Toru; Kasaoka, Masataka; Yamakawa, Ryoji; Yukihikotamai; Nakamura, Shoichiro

    2013-01-01

    To evaluate the clinical use of a newly-developed disposable lid speculum with a drape. LiDrape® is a cylindrical device that consists of two flexible rings of polyacetal resin with a transparent elastic silicone sheet attached to the rings. The novel device holds the eyelids between the rings, and a hole in the center of the device provides a surgical field. We used the novel device in cataract surgery (75 eyes), glaucoma surgery (eleven eyes), vitrectomy (ten eyes), and intravitreal injection (six eyes) and evaluated its clinical efficacy. The LiDrape was easy to attach and detach. The novel device was not detached from the eye during surgery. No eyelashes or secretions from the meibomian glands were seen in the surgical field, and the drape provided a sufficient surgical field. The LiDrape functions as a lid speculum as well as a drape. Our results showed that the novel device is useful for ocular surgeries.

  18. Bilateral Glaucomatous Optic Neuropathy Caused by Eye Rubbing.

    PubMed

    Savastano, Alfonso; Savastano, Maria Cristina; Carlomusto, Laura; Savastano, Silvio

    2015-01-01

    In this report, we describe a particular condition of a 52-year-old man who showed advanced bilateral glaucomatous-like optic disc damage, even though the intraocular pressure resulted normal during all examinations performed. Visual field test, steady-state pattern electroretinogram, retinal nerve fiber layer and retinal tomographic evaluations were performed to evaluate the optic disc damage. Over a 4-year observational period, his visual acuity decreased to 12/20 in the right eye and counting fingers in the left eye. Visual fields were severely compromised, and intraocular pressure values were not superior to 14 mm Hg during routine examinations. An accurate anamnesis and the suspicion of this disease represent a crucial aspect to establish the correct diagnosis. In fact, our patient strongly rubbed his eyes for more than 10 h per day. Recurrent and continuous eye rubbing can induce progressive optic neuropathy, causing severe visual field damage similar to the pathology of advanced glaucoma.

  19. Exploring eye movements in patients with glaucoma when viewing a driving scene.

    PubMed

    Crabb, David P; Smith, Nicholas D; Rauscher, Franziska G; Chisholm, Catharine M; Barbur, John L; Edgar, David F; Garway-Heath, David F

    2010-03-16

    Glaucoma is a progressive eye disease and a leading cause of visual disability. Automated assessment of the visual field determines the different stages in the disease process: it would be desirable to link these measurements taken in the clinic with patient's actual function, or establish if patients compensate for their restricted field of view when performing everyday tasks. Hence, this study investigated eye movements in glaucomatous patients when viewing driving scenes in a hazard perception test (HPT). The HPT is a component of the UK driving licence test consisting of a series of short film clips of various traffic scenes viewed from the driver's perspective each containing hazardous situations that require the camera car to change direction or slow down. Data from nine glaucomatous patients with binocular visual field defects and ten age-matched control subjects were considered (all experienced drivers). Each subject viewed 26 different films with eye movements simultaneously monitored by an eye tracker. Computer software was purpose written to pre-process the data, co-register it to the film clips and to quantify eye movements and point-of-regard (using a dynamic bivariate contour ellipse analysis). On average, and across all HPT films, patients exhibited different eye movement characteristics to controls making, for example, significantly more saccades (P<0.001; 95% confidence interval for mean increase: 9.2 to 22.4%). Whilst the average region of 'point-of-regard' of the patients did not differ significantly from the controls, there were revealing cases where patients failed to see a hazard in relation to their binocular visual field defect. Characteristics of eye movement patterns in patients with bilateral glaucoma can differ significantly from age-matched controls when viewing a traffic scene. Further studies of eye movements made by glaucomatous patients could provide useful information about the definition of the visual field component required for fitness to drive.

  20. Exploring Eye Movements in Patients with Glaucoma When Viewing a Driving Scene

    PubMed Central

    Crabb, David P.; Smith, Nicholas D.; Rauscher, Franziska G.; Chisholm, Catharine M.; Barbur, John L.; Edgar, David F.; Garway-Heath, David F.

    2010-01-01

    Background Glaucoma is a progressive eye disease and a leading cause of visual disability. Automated assessment of the visual field determines the different stages in the disease process: it would be desirable to link these measurements taken in the clinic with patient's actual function, or establish if patients compensate for their restricted field of view when performing everyday tasks. Hence, this study investigated eye movements in glaucomatous patients when viewing driving scenes in a hazard perception test (HPT). Methodology/Principal Findings The HPT is a component of the UK driving licence test consisting of a series of short film clips of various traffic scenes viewed from the driver's perspective each containing hazardous situations that require the camera car to change direction or slow down. Data from nine glaucomatous patients with binocular visual field defects and ten age-matched control subjects were considered (all experienced drivers). Each subject viewed 26 different films with eye movements simultaneously monitored by an eye tracker. Computer software was purpose written to pre-process the data, co-register it to the film clips and to quantify eye movements and point-of-regard (using a dynamic bivariate contour ellipse analysis). On average, and across all HPT films, patients exhibited different eye movement characteristics to controls making, for example, significantly more saccades (P<0.001; 95% confidence interval for mean increase: 9.2 to 22.4%). Whilst the average region of ‘point-of-regard’ of the patients did not differ significantly from the controls, there were revealing cases where patients failed to see a hazard in relation to their binocular visual field defect. Conclusions/Significance Characteristics of eye movement patterns in patients with bilateral glaucoma can differ significantly from age-matched controls when viewing a traffic scene. Further studies of eye movements made by glaucomatous patients could provide useful information about the definition of the visual field component required for fitness to drive. PMID:20300522

  1. The Advanced Glaucoma Intervention Study (AGIS): 7. The relationship between control of intraocular pressure and visual field deterioration.The AGIS Investigators.

    PubMed

    2000-10-01

    To investigate the association between control of intraocular pressure after surgical intervention for glaucoma and visual field deterioration. In the Advanced Glaucoma Intervention Study, eyes were randomly assigned to one of two sequences of glaucoma surgery, one beginning with argon laser trabeculoplasty and the other trabeculectomy. In the present article we examine the relationship between intraocular pressure and progression of visual field damage over 6 or more years of follow-up. In the first analysis, designated Predictive Analysis, we categorize 738 eyes into three groups based on intraocular pressure determinations over the first three 6-month follow-up visits. In the second analysis, designated Associative Analysis, we categorize 586 eyes into four groups based on the percent of 6-month visits over the first 6 follow-up years in which eyes presented with intraocular pressure less than 18 mm Hg. The outcome measure in both analyses is change from baseline in follow-up visual field defect score (range, 0 to 20 units). In the Predictive Analysis, eyes with early average intraocular pressure greater than 17.5 mm Hg had an estimated worsening during subsequent follow-up that was 1 unit of visual field defect score greater than eyes with average intraocular pressure less than 14 mm Hg (P =.002). This amount of worsening was greater at 7 years (1.89 units; P <.001) than at 2 years (0.64 units; P =.071). In the Associative Analysis, eyes with 100% of visits with intraocular pressure less than 18 mm Hg over 6 years had mean changes from baseline in visual field defect score close to zero during follow-up, whereas eyes with less than 50% of visits with intraocular pressure less than 18 mm Hg had an estimated worsening over follow-up of 0.63 units of visual field defect score (P =.083). This amount of worsening was greater at 7 years (1.93 units; P <.001) than at 2 years (0.25 units; P =.572). In both analyses low intraocular pressure is associated with reduced progression of visual field defect, supporting evidence from earlier studies of a protective role for low intraocular pressure in visual field deterioration.

  2. Glaucoma management in patients with osteo-odonto-keratoprosthesis (OOKP): the Singapore OOKP Study.

    PubMed

    Kumar, Rajesh S; Tan, Donald T H; Por, Yong-Ming; Oen, Francis T; Hoh, Sek-Tien; Parthasarathy, Anand; Aung, Tin

    2009-01-01

    To report diagnostic modalities and treatment options for glaucoma in eyes with osteo-odonto keratoprosthesis (OOKP). Eyes that underwent OOKP were evaluated for glaucoma at the time of the first postoperative visit, then at 1 and 3 months after the procedure, and thereafter every 6 months. All eyes underwent stereo-biomicroscopic optic nerve head (ONH) assessment, kinetic (Goldmann perimetry) and automated static visual field testing, ONH photography, Heidelberg retina tomograph, scanning laser polarimetery (GDx), and optical coherence tomography. Treatment of glaucoma was also reviewed. Average follow-up period was 19.1 (range: 5 to 31) months. Of the 15 eyes that underwent OOKP, 5 eyes had preexisting glaucoma. None of the other 10 eyes developed glaucoma after OOKP. ONH photography and visual field testing were the most reliable methods to assess status of the disease, whereas Heidelberg retina tomograph and optical coherence tomography could be performed with reasonable reproducibility and quality; GDx imaging was poor. All patients with glaucoma were treated with oral acetazolamide 500 mg twice a day. Transscleral cyclophotocoagulation was performed in 3 eyes at stage 2 of OOKP surgery. Progression of glaucoma was noted in 2 eyes on the basis of optic disc photographs and automated perimetry. Visual field testing and optic disc assessment with optic disc photographs seem to be effective methods to monitor eyes with OOKP for glaucoma. Treatment strategies include oral medications to lower intraocular pressure and cyclophotocoagulation.

  3. Bilateral Neuroretinitis in Cat Scratch Disease with Exudative, Obliterative Vasculitis in the Optic Disc.

    PubMed

    Tagawa, Yoshiaki; Suzuki, Yasuo; Sakaguchi, Takatoshi; Endoh, Hiroki; Yokoi, Masahiko; Kase, Manabu

    2014-01-01

    A 29-year-old fisherman exhibited optic disc oedema and peripapillary retinal detachment in the right eye, whereas in the left eye, optic atrophy and intraretinal exudates were already observed on first examination. About 6 months earlier, he noticed blurred vision of the left eye but took no medication. Visual acuity was 0.4 OD and 0.01 OS. Perimetry showed a large lower-half field defect with sparing 10° central field in the right eye and a large central scotoma in the left eye. Fluorescein angiography showed existence of arteriole or capillary nonperfusion and hyperpermeability of surrounding capillaries. Since serological examinations showed positive Bartonella immunoglobulin G (IgG) and other causes of neuroretinitis (NR) were excluded, NR in the present case was caused by cat scratch disease (CSD). Optic atrophy appeared 2 weeks after onset. Optical coherence tomography 13 weeks after onset revealed severe loss of retinal nerve fibre layer (RNFL) superior and nasal to the optic disc in both eyes and temporal in the left eye. Visual acuity of the right eye improved to 1.2 by the treatment, whereas visual field defects were persistent. CSD-NR in the present case developed abrupt appearance of optic atrophy with severe RNFL loss in the right eye, which was elicited by exudative, obliterative vasculitis in the superficial layer of the optic disc.

  4. Scanning laser polarimetry, but not optical coherence tomography predicts permanent visual field loss in acute nonarteritic anterior ischemic optic neuropathy.

    PubMed

    Kupersmith, Mark J; Anderson, Susan; Durbin, Mary; Kardon, Randy

    2013-08-15

    Scanning laser polarimetry (SLP) reveals abnormal retardance of birefringence in locations of the edematous peripapillary retinal nerve fiber layer (RNFL), which appear thickened by optical coherence tomography (OCT), in nonarteritic anterior ischemic optic neuropathy (NAION). We hypothesize initial sector SLP RNFL abnormalities will correlate with long-term regional visual field loss due to ischemic injury. We prospectively performed automated perimetry, SLP, and high definition OCT (HD-OCT) of the RNFL in 25 eyes with acute NAION. We grouped visual field threshold and RNFL values into Garway-Heath inferior/superior disc sectors and corresponding superior/inferior field regions. We compared sector SLP RNFL thickness with corresponding visual field values at presentation and at >3 months. At presentation, 12 eyes had superior sector SLP reduction, 11 of which had inferior field loss. Six eyes, all with superior field loss, had inferior sector SLP reduction. No eyes had reduced OCT-derived RNFL acutely. Eyes with abnormal field regions had corresponding SLP sectors thinner (P = 0.003) than for sectors with normal field regions. During the acute phase, the SLP-derived sector correlated with presentation (r = 0.59, P = 0.02) and with >3-month after presentation (r = 0.44, P = 0.02) corresponding superior and inferior field thresholds. Abnormal RNFL birefringence occurs in sectors corresponding to regional visual field loss during acute NAION when OCT-derived RNFL shows thickening. Since the visual field deficits show no significant recovery, SLP can be an early marker for axonal injury, which may be used to assess recovery potential at RNFL locations with respect to new treatments for acute NAION.

  5. The effect of mitomycin C trabeculectomy on the progression of visual field defect in normal-tension glaucoma.

    PubMed

    Hagiwara, Y; Yamamoto, T; Kitazawa, Y

    2000-03-01

    We investigated in a prospective fashion the visual prognosis and complications in normal-tension glaucoma following unilateral trabeculectomy with adjunctive mitomycin C. Trabeculectomy with adjunctive mitomycin C was carried out unilaterally in 21 cases of normal-tension glaucoma. Intraocular pressure (IOP), visual prognosis, and complications were compared between the operated eyes and the non-operated fellow eyes. The follow-up period ranged from 2 to 7 years. The IOP dropped significantly from 14.8+/-1.8 mmHg (mean +/- SD) to 9.6+/-3.9 mmHg in the operated eyes (P=0.0002, Wilcoxon signed-rank test), but did not drop in the non-operated eyes. The mean deviation (MD) was -12.69+/-6.41 dB preoperatively and -14.70+/-5.49 dB at the last clinic visit in the operated eyes, whereas in non-operated eyes it was -7.85+/-5.65 dB and -11.15+/-5.62 dB, respectively. The MD deteriorated significantly in both operated and non-operated eyes (operated eyes P=0.0239, non-operated eyes: P=0.0002; Wilcoxon signed-rank test). The MD slope was -0.37+/-0.60 dB/year and -0.71+/-0.89 dB/year for the operated and non-operated eyes, respectively (P=0.5243, Mann-Whitney U-test). Visual field deterioration was more frequently observed in the non-operated eyes by a pointwise definition of the progression (P<0.05, McNemar test). Visual acuity deteriorated in 6 of the operated eyes and in 5 of the non-operated eyes. Cataract developed in 6 (29%) of the 21 operated eyes, while among the non-operated eyes 4 (19%) developed cataract. Mitomycin C trabeculectomy is effective in delaying progression of visual field defect in normal-tension glaucoma, but complications may arise and cause some visual disturbance.

  6. A field evaluation of the Eye-Closure Interview with witnesses of serious crimes.

    PubMed

    Vredeveldt, Annelies; Tredoux, Colin G; Nortje, Alicia; Kempen, Kate; Puljević, Cheneal; Labuschagne, Gérard N

    2015-04-01

    Laboratory research shows that eye-closure during memory retrieval improves both the amount and the factual accuracy of memory reports about witnessed events. Based on these findings, we developed the Eye-Closure Interview, and examined its feasibility (in terms of compliance with the instructions) and effectiveness (in terms of the quantity and quality of reported information) in eyewitness interviews conducted by the South African Police Service. Police interviewers from the Facial Identification Unit were randomly assigned to receive Eye-Closure Interview training or no training. We analyzed 95 interviews with witnesses of serious crimes (including robbery, rape, and murder), some of whom were instructed to close their eyes during salient parts of the interview. Witnesses in the control condition rarely spontaneously closed their eyes, but witnesses in the Eye-Closure Interview condition kept their eyes closed during 97% of their descriptions, suggesting that the Eye-Closure Interview would be easy to implement in a field setting. Although witnesses who closed their eyes did not remember more information overall, the information they provided was considered to be of significantly greater forensic relevance (as reflected in 2 independent blind assessments, 1 by a senior police expert and 1 by a senior researcher). Thus, based on the findings from this field study and from previous laboratory research, we conclude that implementation of the Eye-Closure Interview in witness interviews would help police interviewers to elicit more valuable information from witnesses, which could be relevant to the police investigation and/or in court. (PsycINFO Database Record (c) 2015 APA, all rights reserved).

  7. Hypodense regions (holes) in the retinal nerve fiber layer in frequency-domain OCT scans of glaucoma patients and suspects.

    PubMed

    Xin, Daiyan; Talamini, Christine L; Raza, Ali S; de Moraes, Carlos Gustavo V; Greenstein, Vivienne C; Liebmann, Jeffrey M; Ritch, Robert; Hood, Donald C

    2011-09-09

    To better understand hypodense regions (holes) that appear in the retinal nerve fiber layer (RNFL) of frequency-domain optical coherence tomography (fdOCT) scans of patients with glaucoma and glaucoma suspects. Peripapillary circle (1.7-mm radius) and cube optic disc fdOCT scans were obtained on 208 eyes from 110 patients (57.4 ± 13.2 years) with glaucomatous optic neuropathy (GON) and 45 eyes of 45 controls (48.0 ± 12.6 years) with normal results of fundus examination. Holes in the RNFL were identified independently by two observers on the circle scans. Holes were found in 33 (16%) eyes of 28 (25%) patients; they were not found in any of the control eyes. Twenty-four eyes had more than one hole. Although some holes were relatively large, others were small. In general, the holes were located adjacent to blood vessels; only three eyes had isolated holes that were not adjacent to a vessel. The holes tended to be in the regions that are thickest in healthy controls and were associated with arcuate defects in patients. Holes were not seen in the center of the temporal disc region. They were more common in the superior (25 eyes) than in the inferior (15 eyes) disc. Of the 30 eyes with holes with reliable visual fields, seven were glaucoma suspect eyes with normal visual fields. The holes in the RNFL seen in patients with GON were probably due to a local loss of RNFL fibers and can occur in the eyes of glaucoma suspects with normal visual fields.

  8. [Visual field progression in glaucoma: cluster analysis].

    PubMed

    Bresson-Dumont, H; Hatton, J; Foucher, J; Fonteneau, M

    2012-11-01

    Visual field progression analysis is one of the key points in glaucoma monitoring, but distinction between true progression and random fluctuation is sometimes difficult. There are several different algorithms but no real consensus for detecting visual field progression. The trend analysis of global indices (MD, sLV) may miss localized deficits or be affected by media opacities. Conversely, point-by-point analysis makes progression difficult to differentiate from physiological variability, particularly when the sensitivity of a point is already low. The goal of our study was to analyse visual field progression with the EyeSuite™ Octopus Perimetry Clusters algorithm in patients with no significant changes in global indices or worsening of the analysis of pointwise linear regression. We analyzed the visual fields of 162 eyes (100 patients - 58 women, 42 men, average age 66.8 ± 10.91) with ocular hypertension or glaucoma. For inclusion, at least six reliable visual fields per eye were required, and the trend analysis (EyeSuite™ Perimetry) of visual field global indices (MD and SLV), could show no significant progression. The analysis of changes in cluster mode was then performed. In a second step, eyes with statistically significant worsening of at least one of their clusters were analyzed point-by-point with the Octopus Field Analysis (OFA). Fifty four eyes (33.33%) had a significant worsening in some clusters, while their global indices remained stable over time. In this group of patients, more advanced glaucoma was present than in stable group (MD 6.41 dB vs. 2.87); 64.82% (35/54) of those eyes in which the clusters progressed, however, had no statistically significant change in the trend analysis by pointwise linear regression. Most software algorithms for analyzing visual field progression are essentially trend analyses of global indices, or point-by-point linear regression. This study shows the potential role of analysis by clusters trend. However, for best results, it is preferable to compare the analyses of several tests in combination with morphologic exam. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  9. Performance under dichoptic versus binocular viewing conditions - Effects of attention and task requirements

    NASA Technical Reports Server (NTRS)

    Kimchi, Ruth; Gopher, Daniel; Rubin, Yifat; Raij, David

    1993-01-01

    Three experiments investigated subjects' ability to allocate attention and cope with task requirements under dichoptic versus binocular viewing conditions. Experiments 1 and 2 employed a target detection task in compound and noncompound stimuli, and Experiment 3 employed a relative-proximity judgment task. The tasks were performed in a focused attention condition in which subjects had to attend to the stimulus presented to one eye or field (under dichoptic and binocular viewing conditions, respectively) while ignoring the stimulus presented to the other eye or field, and in a divided attention condition in which subjects had to attend to the stimuli presented to both eyes or fields. Subjects' performance was affected by the interaction of attention conditions with task requirements, but it was generally the same under dichoptic and binocular viewing conditions. The more dependent the task was on finer discrimination, the more performance was impaired by divided attention. These results suggest that at least with discrete tasks and relatively short exposure durations, performance when each eye is presented with a separate stimulus is the same as when the entire field of stimulation is viewed by both eyes.

  10. Orienting movements in area 9 identified by long-train ICMS.

    PubMed

    Lanzilotto, M; Perciavalle, V; Lucchetti, C

    2015-03-01

    The effect of intracortical microstimulation has been studied in several cortical areas from motor to sensory areas. The frontal pole has received particular attention, and several microstimulation studies have been conducted in the frontal eye field, supplementary eye field, and the premotor ear-eye field, but no microstimulation studies concerning area 9 are currently available in the literature. In the present study, to fill up this gap, electrical microstimulation was applied to area 9 in two macaque monkeys using long-train pulses of 500-700-800 and 1,000 ms, during two different experimental conditions: a spontaneous condition, while the animals were not actively fixating on a visual target, and during a visual fixation task. In these experiments, we identified backward ear movements, goal-directed eye movements, and the development of head forces. Kinematic parameters for ear and eye movements overlapped in the spontaneous condition, but they were different during the visual fixation task. In this condition, ear and eye kinematics have an opposite behavior: movement amplitude, duration, and maximal and mean velocities increase during a visual fixation task for the ear, while they decrease for the eye. Therefore, a top-down visual attention engagement could modify the kinematic parameters for these two effectors. Stimulation with the longest train durations, i.e., 800/1,000 ms, evokes not only the highest eye amplitude, but also a significant development of head forces. In this research article, we propose a new vision of the frontal oculomotor fields, speculating a role for area 9 in the control of goal-directed orienting behaviors and gaze shift control.

  11. Eye-Tracking as a Tool to Evaluate Functional Ability in Everyday Tasks in Glaucoma.

    PubMed

    Kasneci, Enkelejda; Black, Alex A; Wood, Joanne M

    2017-01-01

    To date, few studies have investigated the eye movement patterns of individuals with glaucoma while they undertake everyday tasks in real-world settings. While some of these studies have reported possible compensatory gaze patterns in those with glaucoma who demonstrated good task performance despite their visual field loss, little is known about the complex interaction between field loss and visual scanning strategies and the impact on task performance and, consequently, on quality of life. We review existing approaches that have quantified the effect of glaucomatous visual field defects on the ability to undertake everyday activities through the use of eye movement analysis. Furthermore, we discuss current developments in eye-tracking technology and the potential for combining eye-tracking with virtual reality and advanced analytical approaches. Recent technological developments suggest that systems based on eye-tracking have the potential to assist individuals with glaucomatous loss to maintain or even improve their performance on everyday tasks and hence enhance their long-term quality of life. We discuss novel approaches for studying the visual search behavior of individuals with glaucoma that have the potential to assist individuals with glaucoma, through the use of personalized programs that take into consideration the individual characteristics of their remaining visual field and visual search behavior.

  12. FDTD analysis of temperature elevation in the lens of human and rabbit models due to near-field and far-field exposures at 2.45 GHz.

    PubMed

    Oizumi, Takuya; Laakso, Ilkka; Hirata, Akimasa; Fujiwara, Osamu; Watanabe, Soichi; Taki, Masao; Kojima, Masami; Sasaki, Hiroshi; Sasaki, Kazuyuki

    2013-07-01

    The eye is said to be one of the most sensitive organs to microwave heating. According to previous studies, the possibility of microwave-induced cataract formation has been experimentally investigated in rabbit and monkey eyes, but not for the human eye due to ethical reasons. In the present study, the temperature elevation in the lens, the skin around the eye and the core temperature of numerical human and rabbit models for far-field and near-field exposures at 2.45 GHz are investigated. The temperature elevations in the human and rabbit models were compared with the threshold temperatures for inducing cataracts, thermal pain in the skin and reversible health effects such as heat exhaustion or heat stroke. For plane-wave exposure, the core temperature elevation is shown to be essential both in the human and in the rabbit models as suggested in the international guidelines and standards. For localised exposure of the human eye, the temperature elevation of the skin was essential, and the lens temperature did not reach its threshold for thermal pain. On the other hand, the lens temperature elevation was found to be dominant for the rabbit eye.

  13. Testing of visual field with virtual reality goggles in manual and visual grasp modes.

    PubMed

    Wroblewski, Dariusz; Francis, Brian A; Sadun, Alfredo; Vakili, Ghazal; Chopra, Vikas

    2014-01-01

    Automated perimetry is used for the assessment of visual function in a variety of ophthalmic and neurologic diseases. We report development and clinical testing of a compact, head-mounted, and eye-tracking perimeter (VirtualEye) that provides a more comfortable test environment than the standard instrumentation. VirtualEye performs the equivalent of a full threshold 24-2 visual field in two modes: (1) manual, with patient response registered with a mouse click, and (2) visual grasp, where the eye tracker senses change in gaze direction as evidence of target acquisition. 59 patients successfully completed the test in manual mode and 40 in visual grasp mode, with 59 undergoing the standard Humphrey field analyzer (HFA) testing. Large visual field defects were reliably detected by VirtualEye. Point-by-point comparison between the results obtained with the different modalities indicates: (1) minimal systematic differences between measurements taken in visual grasp and manual modes, (2) the average standard deviation of the difference distributions of about 5 dB, and (3) a systematic shift (of 4-6 dB) to lower sensitivities for VirtualEye device, observed mostly in high dB range. The usability survey suggested patients' acceptance of the head-mounted device. The study appears to validate the concepts of a head-mounted perimeter and the visual grasp mode.

  14. Eye-Tracking as a Tool to Evaluate Functional Ability in Everyday Tasks in Glaucoma

    PubMed Central

    Black, Alex A.

    2017-01-01

    To date, few studies have investigated the eye movement patterns of individuals with glaucoma while they undertake everyday tasks in real-world settings. While some of these studies have reported possible compensatory gaze patterns in those with glaucoma who demonstrated good task performance despite their visual field loss, little is known about the complex interaction between field loss and visual scanning strategies and the impact on task performance and, consequently, on quality of life. We review existing approaches that have quantified the effect of glaucomatous visual field defects on the ability to undertake everyday activities through the use of eye movement analysis. Furthermore, we discuss current developments in eye-tracking technology and the potential for combining eye-tracking with virtual reality and advanced analytical approaches. Recent technological developments suggest that systems based on eye-tracking have the potential to assist individuals with glaucomatous loss to maintain or even improve their performance on everyday tasks and hence enhance their long-term quality of life. We discuss novel approaches for studying the visual search behavior of individuals with glaucoma that have the potential to assist individuals with glaucoma, through the use of personalized programs that take into consideration the individual characteristics of their remaining visual field and visual search behavior. PMID:28293433

  15. Acquired color vision and visual field defects in patients with ocular hypertension and early glaucoma.

    PubMed

    Papaconstantinou, Dimitris; Georgalas, Ilias; Kalantzis, George; Karmiris, Efthimios; Koutsandrea, Chrysanthi; Diagourtas, Andreas; Ladas, Ioannis; Georgopoulos, Gerasimos

    2009-01-01

    To study acquired color vision and visual field defects in patients with ocular hypertension (OH) and early glaucoma. In a prospective study we evaluated 99 eyes of 56 patients with OH without visual field defects and no hereditary color deficiencies, followed up for 4 to 6 years (mean = 4.7 +/- 0.6 years). Color vision defects were studied using a special computer program for Farnsworth-Munsell 100 hue test and visual field tests were performed with Humphrey analyzer using program 30-2. Both tests were repeated every six months. In fifty-six eyes, glaucomatous defects were observed during the follow-up period. There was a statistically significant difference in total error score (TES) between eyes that eventually developed glaucoma (157.89 +/- 31.79) and OH eyes (75.51 +/- 31.57) at the first examination (t value 12.816, p < 0.001). At the same time visual field indices were within normal limits in both groups. In the glaucomatous eyes the earliest statistical significant change in TES was identified at the first year of follow-up and was -20.62 +/- 2.75 (t value 9.08, p < 0.001) while in OH eyes was -2.11 +/- 4.36 (t value 1.1, p = 0.276). Pearson's coefficient was high in all examinations and showed a direct correlation between TES and mean deviation and corrected pattern standard deviation in both groups. Quantitative analysis of color vision defects provides the possibility of follow-up and can prove a useful means for detecting early glaucomatous changes in patients with normal visual fields.

  16. Early detection of glaucoma by means of a novel 3D computer‐automated visual field test

    PubMed Central

    Nazemi, Paul P; Fink, Wolfgang; Sadun, Alfredo A; Francis, Brian; Minckler, Donald

    2007-01-01

    Purpose A recently devised 3D computer‐automated threshold Amsler grid test was used to identify early and distinctive defects in people with suspected glaucoma. Further, the location, shape and depth of these field defects were characterised. Finally, the visual fields were compared with those obtained by standard automated perimetry. Patients and methods Glaucoma suspects were defined as those having elevated intraocular pressure (>21 mm Hg) or cup‐to‐disc ratio of >0.5. 33 patients and 66 eyes with risk factors for glaucoma were examined. 15 patients and 23 eyes with no risk factors were tested as controls. The recently developed 3D computer‐automated threshold Amsler grid test was used. The test exhibits a grid on a computer screen at a preselected greyscale and angular resolution, and allows patients to trace those areas on the grid that are missing in their visual field using a touch screen. The 5‐minute test required that the patients repeatedly outline scotomas on a touch screen with varied displays of contrast while maintaining their gaze on a central fixation marker. A 3D depiction of the visual field defects was then obtained that was further characterised by the location, shape and depth of the scotomas. The exam was repeated three times per eye. The results were compared to Humphrey visual field tests (ie, achromatic standard or SITA standard 30‐2 or 24‐2). Results In this pilot study 79% of the eyes tested in the glaucoma‐suspect group repeatedly demonstrated visual field loss with the 3D perimetry. The 3D depictions of visual field loss associated with these risk factors were all characteristic of or compatible with glaucoma. 71% of the eyes demonstrated arcuate defects or a nasal step. Constricted visual fields were shown in 29% of the eyes. No visual field changes were detected in the control group. Conclusions The 3D computer‐automated threshold Amsler grid test may demonstrate visual field abnormalities characteristic of glaucoma in glaucoma suspects with normal achromatic Humphrey visual field testing. This test may be used as a screening tool for the early detection of glaucoma. PMID:17504855

  17. Three-Dimensional Enhanced Imaging of Vitreoretinal Interface in Diabetic Retinopathy Using Swept-Source Optical Coherence Tomography.

    PubMed

    Adhi, Mehreen; Badaro, Emmerson; Liu, Jonathan J; Kraus, Martin F; Baumal, Caroline R; Witkin, Andre J; Hornegger, Joachim; Fujimoto, James G; Duker, Jay S; Waheed, Nadia K

    2016-02-01

    To analyze the vitreoretinal interface in diabetic eyes using 3-dimensional wide-field volumes acquired using high-speed, long-wavelength swept-source optical coherence tomography (SSOCT). Prospective cross-sectional study. Fifty-six diabetic patients (88 eyes) and 11 healthy nondiabetic controls (22 eyes) were recruited. Up to 8 SSOCT volumes were acquired for each eye. A registration algorithm removed motion artifacts and merged multiple SSOCT volumes to improve signal. Vitreous visualization was enhanced using vitreous windowing method. Of 88 diabetic eyes, 20 eyes had no retinopathy, 21 eyes had nonproliferative diabetic retinopathy (NPDR) without macular edema, 20 eyes had proliferative diabetic retinopathy (PDR) without macular edema, and 27 eyes had diabetic macular edema (DME) with either NPDR or PDR. Thick posterior hyaloid relative to healthy nondiabetic controls was observed in 0 of 20 (0%) diabetic eyes without retinopathy, 4 of 21 (19%) eyes with NPDR, 11 of 20 (55%) eyes with PDR, and 11 of 27 (41%) eyes with DME (P = .0001). Vitreoschisis was observed in 6 of 22 (27%) healthy nondiabetic eyes, 9 of 20 (45%) diabetic eyes without retinopathy, 10 of 21 (48%) eyes with NPDR, 13 of 20 (65%) eyes with PDR, and 17 of 27 (63%) eyes with DME (P = .007). While no healthy nondiabetic controls and diabetic eyes without retinopathy had adhesions/pegs between detached posterior hyaloid and retina, 1 of 21 (4%), 11 of 20 (55%), and 11 of 27 (41%) eyes with NPDR, PDR, and DME, respectively, demonstrated this feature (P = .0001). SSOCT with motion-correction and vitreous windowing provides wide-field 3-dimensional information of vitreoretinal interface in diabetic eyes. This may be useful in assessing progression of retinopathy, planning diabetic vitreous surgery, and predicting treatment outcomes. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Angular and linear fields of view of Galilean telescopes and telemicroscopes.

    PubMed

    Katz, Milton

    2007-06-01

    The calculation of the angular fields of view (FOVs) of Galilean telescopes generally necessitates the calculation of the pupils and ports. This, in turn, requires knowledge of the optical design of the telescope, in particular, the focal lengths or powers of the objective and ocular lenses. Equations for finding the FOV that obviate the need to calculate pupils and ports, or even to know the lens powers of the telescope, are presented in this article. The equations can be used to find the FOVs in image space of real Galilean telescopes of known magnification, merely by measuring the distance between the objective and ocular lenses and the diameter of the objective lens. The equations include the effects of eye pupil diameter and eye relief. Linear FOVs (LFOVs) of Galilean telemicroscopes are similarly determined. Two image space angular FOV equations were derived: (1) an equation to determine the angular FOVs of a telescope with various amounts of vignetting and eye relief; and (2) an equivalent equation for the LFOVs of telescopes fitted with lens caps for near vision. The FOV increases linearly with increasing vignetting. Increasing the eye relief results in a nonlinear decrease in the FOV, shown as a fraction of the normalized value for zero eye relief. Decrements in the FOVs with increasing eye relief as a fraction of the normalized field angle when the eye relief = 0 are shown to be constant regardless of the vignetting level. A transition of the objective lens from field stop to aperture stop occurs when the eye pupil diameter exceeds the diameter of the objective lens divided by the magnification. Equations have been derived for Galilean telescopes and telemicroscopes that make it unnecessary to find pupils and ports, or to know the powers of the lenses. They provide a direct and simple evaluation of angular and LFOVs as functions of magnification, objective lens diameter, eye pupil diameter, eye relief, and vignetting, and enable comparisons of actual telescopes.

  19. Differentiation between Vergence and Saccadic Functional Activity within the Human Frontal Eye Fields and Midbrain Revealed through fMRI

    PubMed Central

    Alkan, Yelda; Biswal, Bharat B.; Alvarez, Tara L.

    2011-01-01

    Purpose Eye movement research has traditionally studied solely saccade and/or vergence eye movements by isolating these systems within a laboratory setting. While the neural correlates of saccadic eye movements are established, few studies have quantified the functional activity of vergence eye movements using fMRI. This study mapped the neural substrates of vergence eye movements and compared them to saccades to elucidate the spatial commonality and differentiation between these systems. Methodology The stimulus was presented in a block design where the ‘off’ stimulus was a sustained fixation and the ‘on’ stimulus was random vergence or saccadic eye movements. Data were collected with a 3T scanner. A general linear model (GLM) was used in conjunction with cluster size to determine significantly active regions. A paired t-test of the GLM beta weight coefficients was computed between the saccade and vergence functional activities to test the hypothesis that vergence and saccadic stimulation would have spatial differentiation in addition to shared neural substrates. Results Segregated functional activation was observed within the frontal eye fields where a portion of the functional activity from the vergence task was located anterior to the saccadic functional activity (z>2.3; p<0.03). An area within the midbrain was significantly correlated with the experimental design for the vergence but not the saccade data set. Similar functional activation was observed within the following regions of interest: the supplementary eye field, dorsolateral prefrontal cortex, ventral lateral prefrontal cortex, lateral intraparietal area, cuneus, precuneus, anterior and posterior cingulates, and cerebellar vermis. The functional activity from these regions was not different between the vergence and saccade data sets assessed by analyzing the beta weights of the paired t-test (p>0.2). Conclusion Functional MRI can elucidate the differences between the vergence and saccade neural substrates within the frontal eye fields and midbrain. PMID:22073141

  20. Tutorial on Biostatistics: Linear Regression Analysis of Continuous Correlated Eye Data.

    PubMed

    Ying, Gui-Shuang; Maguire, Maureen G; Glynn, Robert; Rosner, Bernard

    2017-04-01

    To describe and demonstrate appropriate linear regression methods for analyzing correlated continuous eye data. We describe several approaches to regression analysis involving both eyes, including mixed effects and marginal models under various covariance structures to account for inter-eye correlation. We demonstrate, with SAS statistical software, applications in a study comparing baseline refractive error between one eye with choroidal neovascularization (CNV) and the unaffected fellow eye, and in a study determining factors associated with visual field in the elderly. When refractive error from both eyes were analyzed with standard linear regression without accounting for inter-eye correlation (adjusting for demographic and ocular covariates), the difference between eyes with CNV and fellow eyes was 0.15 diopters (D; 95% confidence interval, CI -0.03 to 0.32D, p = 0.10). Using a mixed effects model or a marginal model, the estimated difference was the same but with narrower 95% CI (0.01 to 0.28D, p = 0.03). Standard regression for visual field data from both eyes provided biased estimates of standard error (generally underestimated) and smaller p-values, while analysis of the worse eye provided larger p-values than mixed effects models and marginal models. In research involving both eyes, ignoring inter-eye correlation can lead to invalid inferences. Analysis using only right or left eyes is valid, but decreases power. Worse-eye analysis can provide less power and biased estimates of effect. Mixed effects or marginal models using the eye as the unit of analysis should be used to appropriately account for inter-eye correlation and maximize power and precision.

  1. Interocular Difference of Peripheral Refraction in Anisomyopic Eyes of Schoolchildren

    PubMed Central

    Chen, Junhong; He, Ji C.; Chen, Yunyun; Xu, Jingjing; Wu, Haoran; Wang, Feifu; Lu, Fan; Jiang, Jun

    2016-01-01

    Purpose Refraction in the peripheral visual field is believed to play an important role in the development of myopia. The purpose of this study was to investigate the differences in peripheral refraction among anisomyopia, isomyopia, and isoemmetropia for schoolchildren. Methods Thirty-eight anisomyopic children were recruited and divided into two groups: (1) both eyes were myopic (anisomyopic group, AM group) and (2) one eye was myopic and the contralateral eye was emmetropic (emmetropic anisomyopic group, EAM group). As controls, 45 isomyopic and isoemmetropic children were also recruited with age and central spherical equivalent (SE) matched to those of the AM and EAM groups. The controls were divided into three groups: (1) intermediate myopia group (SE matched to the more myopic eye of AM group), (2) low myopia group (SE matched to the less myopic eye of AM group and the more myopic eye of EAM group), and (3) emmetropia group (SE matched to the less myopic eye of EAM group). Peripheral refraction at 7 points across the central ±30° on the horizontal visual field with a 10° interval was measured with an autorefractor. Axial length (AL), corneal curvature (CC), and anterior chamber depth (ACD) were also determined by using the Zeiss IOL-Master. Results The relative peripheral spherical equivalent [RPR(M)] and relative peripheral spherical value [RPR(S)] of the more myopic eye was shifted more hyperopically than the contralateral eye in both the AM and the EAM groups (both p<0.0001). The RPR(M, S) of the less myopic eyes in the AM and EAM groups showed a relatively flat trend across the visual field and were not significantly different from the emmetropia group. The RPR(M, S) of less myopic eyes in the AM group were shifted less hyperopically than in the isomyopic low myopia group and the more myopic eye of the EAM group [RPR(M), p = 0.007; RPR(S), p = 0.001], although the central SEs of the three groups were not significantly different from each other. However, RPR(M, S) of the more myopic eyes were not different from the corresponding isomyopic groups. There was also no significant difference in the relative peripheral astigmatism [RPR(J0, J45)] between the more and the less myopic eyes in either the AM or the EAM group. Conclusion Refraction of anisomyopia differs between the two eyes not only at the central visual field but also at the off-axis periphery. The relative peripheral refraction of the more myopic eye of anisomyopia was shifted hyperopically, as occurs in isomyopia with similar central subjective SE values. Less myopic eyes were much less hyperopically shifted in relative peripheral refraction than the corresponding isomyopic eyes, but are comparable to emmetropic eyes. This emmetropia-like relative peripheral refraction in less myopic eyes might be a factor responsible for slowing down the progression of myopia. PMID:26881745

  2. Interocular Difference of Peripheral Refraction in Anisomyopic Eyes of Schoolchildren.

    PubMed

    Chen, Junhong; He, Ji C; Chen, Yunyun; Xu, Jingjing; Wu, Haoran; Wang, Feifu; Lu, Fan; Jiang, Jun

    2016-01-01

    Refraction in the peripheral visual field is believed to play an important role in the development of myopia. The purpose of this study was to investigate the differences in peripheral refraction among anisomyopia, isomyopia, and isoemmetropia for schoolchildren. Thirty-eight anisomyopic children were recruited and divided into two groups: (1) both eyes were myopic (anisomyopic group, AM group) and (2) one eye was myopic and the contralateral eye was emmetropic (emmetropic anisomyopic group, EAM group). As controls, 45 isomyopic and isoemmetropic children were also recruited with age and central spherical equivalent (SE) matched to those of the AM and EAM groups. The controls were divided into three groups: (1) intermediate myopia group (SE matched to the more myopic eye of AM group), (2) low myopia group (SE matched to the less myopic eye of AM group and the more myopic eye of EAM group), and (3) emmetropia group (SE matched to the less myopic eye of EAM group). Peripheral refraction at 7 points across the central ±30° on the horizontal visual field with a 10° interval was measured with an autorefractor. Axial length (AL), corneal curvature (CC), and anterior chamber depth (ACD) were also determined by using the Zeiss IOL-Master. The relative peripheral spherical equivalent [RPR(M)] and relative peripheral spherical value [RPR(S)] of the more myopic eye was shifted more hyperopically than the contralateral eye in both the AM and the EAM groups (both p<0.0001). The RPR(M, S) of the less myopic eyes in the AM and EAM groups showed a relatively flat trend across the visual field and were not significantly different from the emmetropia group. The RPR(M, S) of less myopic eyes in the AM group were shifted less hyperopically than in the isomyopic low myopia group and the more myopic eye of the EAM group [RPR(M), p = 0.007; RPR(S), p = 0.001], although the central SEs of the three groups were not significantly different from each other. However, RPR(M, S) of the more myopic eyes were not different from the corresponding isomyopic groups. There was also no significant difference in the relative peripheral astigmatism [RPR(J0, J45)] between the more and the less myopic eyes in either the AM or the EAM group. Refraction of anisomyopia differs between the two eyes not only at the central visual field but also at the off-axis periphery. The relative peripheral refraction of the more myopic eye of anisomyopia was shifted hyperopically, as occurs in isomyopia with similar central subjective SE values. Less myopic eyes were much less hyperopically shifted in relative peripheral refraction than the corresponding isomyopic eyes, but are comparable to emmetropic eyes. This emmetropia-like relative peripheral refraction in less myopic eyes might be a factor responsible for slowing down the progression of myopia.

  3. The research of the style of angel lobster eye x-ray optical system

    NASA Astrophysics Data System (ADS)

    Cheng, HuaQi; Liu, YuJiao; Zhang, ShaoWei; Hou, LinBao; Li, XingLong

    2018-01-01

    This paper has developed the theory research of wide field Angel lobster eye X-ray optical system based on the principle of entirely incidence. Combine the configuration characteristic of lobster eye, recommend the conclusion of beam of light focus on the half of radius whether point or parallel light. Designed the microchannel through the principle of real ray trace and got the relationship among different parameters about it using numerical value emulation. Got pixels and illumination pictures validated the wide field focus characteristic of Angel lobster eye by simulating the optical system.

  4. Eye Movements of Patients with Tunnel Vision while Walking

    PubMed Central

    Vargas-Martín, Fernando; Peli, Eli

    2006-01-01

    Purpose To determine how severe peripheral field loss (PFL) affects the dispersion of eye movements relative to the head, while walking in real environments. This information should help to better define the visual field and clearance requirements for head-mounted mobility visual aids. Methods Eye positions relative to the head were recorded in five retinitis pigmentosa patients with less than 15° of visual field and three normally-sighted people, each walking in varied environments for more than 30 minutes. The eye position recorder was made portable by modifying a head-mounted ISCAN system. Custom data processing was implemented to reject unreliable data. Sample standard deviations of eye position (dispersion) were compared across subject groups and environments. Results PFL patients exhibited narrower horizontal eye position dispersions than normally-sighted subjects (9.4° vs. 14.2°, p < 0.0001) and PFL patients’ vertical dispersions were smaller when walking indoors than outdoors (8.2° vs. 10.3°, p = 0.048). Conclusions When walking, the PFL patients did not increase their scanning eye movements to compensate for missing peripheral vision information. Their horizontal scanning was actually reduced, possibly because saccadic amplitude is limited by a lack of peripheral stimulation. The results suggest that a field-of-view as wide as 40° may be needed for closed (immersive) head-mounted mobility aids, while a much narrower display, perhaps as narrow as 20°, might be sufficient with an open design. PMID:17122116

  5. Eye movements of patients with tunnel vision while walking.

    PubMed

    Vargas-Martín, Fernando; Peli, Eli

    2006-12-01

    To determine how severe peripheral field loss (PFL) affects the dispersion of eye movements relative to the head in patients walking in real environments. This information should help to define the visual field and clearance requirements for head-mounted mobility visual aids. Eye positions relative to the head were recorded in five patients with retinitis pigmentosa who had less than 15 degrees of visual field and in three normally sighted people, each walking in varied environments for more than 30 minutes. The eye-position recorder was made portable by modifying a head-mounted system (ISCAN, Burlington, MA). Custom data processing was implemented, to reject unreliable data. Sample standard deviations of eye position (dispersion) were compared across subject groups and environments. The patients with PFL exhibited narrower horizontal eye-position dispersions than did the normally sighted subjects (9.4 degrees vs. 14.2 degrees , P < 0.0001), and the vertical dispersions of patients with PFL were smaller when they were walking indoors than when walking outdoors (8.2 degrees vs. 10.3 degrees ; P = 0.048). When walking, the patients with PFL did not increase their scanning eye movements to compensate for missing peripheral vision information. Their horizontal scanning was actually reduced, possibly because of lack of peripheral stimulation. The results suggest that a field of view as wide as 40 degrees may be needed for closed (immersive) head-mounted mobility aids, whereas a much narrower display, perhaps as narrow as 20 degrees , may be sufficient with an open design.

  6. Identification of a novel mutation in the PTCH gene in a patient with Gorlin-Goltz syndrome with unusual ocular disorders.

    PubMed

    Romano, Mary; Iacovello, Daniela; Cascone, Nikhil C; Contestabile, Maria Teresa

    2011-01-01

    To document the clinical, functional, and in vivo microanatomic characteristics of a patient with Gorlin-Goltz syndrome with a novel nonsense mutation in PTCH (patched). Optical coherence tomography (OCT), fluorescein angiography, electrophysiologic testing, visual field, magnetic resonance imaging, and mutation screening of PTCH gene. Visual acuity was 20/20 in the right eye and 20/25 in the left. Fundus examination revealed myelinated nerve fibers in the left eye and bilateral epiretinal membranes with lamellar macular hole also documented with macular OCT. A reduction of the retinal nerve fiber layers in both eyes was found with fiber nervous OCT. Fluorescein angiography showed bilaterally foveal hyperfluorescence and the visual field revealed inferior hemianopia in the right eye. Pattern visual evoked potentials registered a reduction of amplitude in both eyes and latency was delayed in the left eye. Pattern electroretinogram showed a reduction in P50 and N95 peak time and a delay in P50 peak time in the left eye. Flash electroretinogram was reduced in rod response, maximal response, and oscillatory potentials in both eyes. Cone response was normal and 30-Hz flicker was slightly reduced in both eyes. Mutation screening identified a novel nonsense mutation in PTCH. A novel nonsense mutation in the PTCH gene was found. We report the occurrence of epiretinal membranes and the persistence of myelinated nerve fibers. Electrophysiologic and visual field alterations, supporting a neuroretinal dysfunction, were also documented.

  7. Terahertz Near-Field Imaging Using Enhanced Transmission through a Single Subwavelength Aperture

    NASA Astrophysics Data System (ADS)

    Ishihara, Kunihiko; Ikari, Tomofumi; Minamide, Hiroaki; Shikata, Jun-ichi; Ohashi, Keishi; Yokoyama, Hiroyuki; Ito, Hiromasa

    2005-07-01

    We demonstrate terahertz (THz) near-field imaging using resonantly enhanced transmission of THz-wave radiation (λ˜ 200 μm) through a bull’s eye structure (a single subwavelength aperture surrounded by concentric periodic grooves in a metal plate). The bull’s eye structure shows extremely large enhanced transmission, which has the advantage for a single subwavelength aperture. The spatial resolution for the bull’s eye structure (with an aperture diameter d=100 μm) is evaluated in the near-field region, and a resolution of 50 μm (corresponding to λ/4) is achieved. We obtain the THz near-field images of the subwavelength metal pattern with a spatial resolution below the diffraction limit.

  8. Nitrogen fertilization interacts with light to increase Rubus spp. cover in a temperate forest

    Treesearch

    Christopher A. Walter; Devon T. Raiff; Mark B. Burnham; Frank S. Gilliam; Mary Beth Adams; William T. Peterjohn

    2016-01-01

    Nitrogen additions have caused species composition changes in many ecosystems by facilitating the growth of nitrophilic species. After 24 years of nitrogen fertilization in a 40 year-old stand at the Fernow Experimental Forest (FEF) in Central Appalachia, USA, the cover of Rubus spp. has increased from 1 to 19 % of total herbaceous-layer cover....

  9. Vegetation and acidification, Chapter 5

    Treesearch

    David R. DeWalle; James N. Kochenderfer; Mary Beth Adams; Gary W. Miller

    2006-01-01

    In this chapter, the impact of watershed acidification treatments on WS3 at the Fernow Experimental Forest (FEF) and at WS9 on vegetation is presented and summarized in a comprehensive way for the first time. WS7 is used as a vegetative reference basin for WS3, while untreated plots within WS9 are used as a vegetative reference for WS9. Bioindicators of acidification...

  10. USDA Forest Service farm woodlands case study - 50 year results from West Virgina

    Treesearch

    David W. McGill; Thomas M. Schuler

    2003-01-01

    Recognizing that fire, grazing, and poor cutting practices had compromised much productivity in farm woodlots in the early 1900s, USDA Forest Service personnel established a demonstration on the Fernow Experimental Forest (FEF) to show the feasibility of two harvesting systems that could be used to maintain or enhance stand productivity and provide private forest land...

  11. Magneto-phonon polaritons of antiferromagnetic/ion-crystal superlattices

    NASA Astrophysics Data System (ADS)

    Ta, Jin-Xing; Song, Yu-Ling; Wang, Xuan-Zhang

    2010-07-01

    Magnetophonon polaritons in the superlattices composed of alternating antiferromagnetic and ion-crystal components are investigated with the transfer matrix method. Numerical simulations based on FeF2/TlBr superlattices show that there are four different bulk polariton bands, with negative refraction and positive refraction. Many surface polariton modes with various features arise around the bulk bands with negative refraction.

  12. Macromolecules for Inhibition of Corrosion and Wear

    DTIC Science & Technology

    1992-12-14

    phthalocyanine TCAUPC tetrakis-(N-carboxy-12-aminoundecanoic acid ) phthalocyanine TCACPC tetrakis-(N-carboxy-6- aminocaproic acid ) phthalocyanine Table 2... acid ); (TCACPC] - tetrakis(N- carboxy-6- aminocaproic acid ). •* Containing p-hydroxy pyridine groups in the voids. 9 NAWCADWAR-92112-60 protection...fluids .......... ................................ 10 8 PFPE degradation in the presence of FeF 3 Lewis Acid ..... 11 9 The degradation mechanism for PFPE

  13. Relating bat species presence to simple habitat measures in a central Appalachian forest

    Treesearch

    W. Mark Ford; Michael A. Menzel; Jane L. Rodrigue; Jennifer M. Menzel; Joshua B. Johnson; Joshua B. Johnson

    2005-01-01

    We actively sampled the bat community at 63 sites using detection and non- detection metrics on the Fernow Experimental Forest (FEF) in the central Appalachians of West Virginia using Anabat acoustical equipment May-June 2001-2003 to relate species presence to simple habitat measures such as proximity to riparian areas, forest canopy cover, forest canopy gap width, and...

  14. USDA Forest Service farm woodlands case study - 50 year results from West Virginia

    Treesearch

    David W. McGill; Thomas M. Schuler

    2003-01-01

    Recognizing that fire, grazing, and poor cutting practices had compromised much productivity in farm woodlots in the early 1900s, USDA Forest Service personnel established a demonstration on the Fernow Experimental Forest (FEF) to show the feasibility of two harvesting systems that could be used to maintain or enhance stand productivity and provide private forest land...

  15. Freeze extrusion fabrication of 13-93 bioactive glass scaffolds for bone repair.

    PubMed

    Doiphode, Nikhil D; Huang, Tieshu; Leu, Ming C; Rahaman, Mohamed N; Day, Delbert E

    2011-03-01

    A solid freeform fabrication technique, freeze extrusion fabrication (FEF), was investigated for the creation of three-dimensional bioactive glass (13-93) scaffolds with pre-designed porosity and pore architecture. An aqueous mixture of bioactive glass particles and polymeric additives with a paste-like consistency was extruded through a narrow nozzle, and deposited layer-by-layer in a cold environment according to a computer-aided design (CAD) file. Following sublimation of the ice in a freeze dryer, the construct was heated according to a controlled schedule to burn out the polymeric additives (below ~500°C), and to densify the glass phase at higher temperature (1 h at 700°C). The sintered scaffolds had a grid-like microstructure of interconnected pores, with a porosity of ~50%, pore width of ~300 μm, and dense glass filaments (struts) with a diameter or width of ~300 μm. The scaffolds showed an elastic response during mechanical testing in compression, with an average compressive strength of 140 MPa and an elastic modulus of 5-6 GPa, comparable to the values for human cortical bone. These bioactive glass scaffolds created by the FEF method could have potential application in the repair of load-bearing bones.

  16. Active catalysts of sonoelectrochemically prepared iron metal nanoparticles for the electroreduction of chloroacetates

    NASA Astrophysics Data System (ADS)

    Sáez, V.; González-García, J.; Marken, F.

    2010-01-01

    A new methodology for the sonoelectro-deposition and stripping of highly reactive iron at boron-doped diamond electrodes has been studied. In aqueous 1 M NH4F iron metal readily and reversibly electro-deposits onto boron-doped diamond electrodes. The effects of deposition potential, FeF63- concentration, deposition time, and mass transport are investigated and also the influence of power ultrasound (24 kHz, 8 Wcm-2). Scanning electron microscopy images of iron nanoparticles grown to typically 20-30 nm diameters are obtained. It is shown that a strongly and permanently adhering film of iron at boron-doped diamond can be formed and transferred into other solution environments. The catalytic reactivity of iron deposits at boron-doped diamond is investigated for the reductive dehalogenation of chloroacetate. The kinetically limited multi-electron reduction of trichloroacetate is dependent on the FeF63- deposition conditions and the solution composition. It is demonstrated that a stepwise iron-catalysed dechlorination via dichloroacetate and monochloroacetate to acetate is feasible. This sonoelectrochemical methodology offers a novel, clean and very versatile electro-dehalogenation methodology. The role of fluoride in the surface electrochemistry of iron deserves further attention.

  17. Decline in lung function among cement production workers: a meta-analysis.

    PubMed

    Moghadam, Somayeh Rahimi; Abedi, Siavosh; Afshari, Mahdi; Abedini, Ehsan; Moosazadeh, Mahmood

    2017-12-20

    Several studies with different results have been performed regarding cement dust exposure and its pathogenic outcomes during the previous years. This study aims to combine these results to obtain a reliable estimate of the effect of exposure to cement dust. PubMed and other data banks were searched to identify required electronic articles. The search was extended interviewing with relevant experts and research centers. Point and pooled estimates of outcome with 95% confidence intervals were estimated. Participants were 5371 exposed and 2650 unexposed persons. Total mean differences (95% confidence intervals) were estimated as of -0.48 (-0.71 to -0.25) L for forced vital capacity (FVC), -0.7 (-0.92 to -0.47) L for forced expiratory volume in the first second (FEV1), -0.43 (-0.68 to -0.19) L for FEV1/FVC%, -0.73 (-1.15 to -0.30) L/min for PEFR and -0.36 (-0.51 to -0.21) L/s for FEF25-75. Our meta-analysis showed that cement dust has significant impact on lung function and reduces the indicators of FVC, FEV1, FEV1/FVC, PEFR and FEF25-75.

  18. Pulmonary functions in tannery workers--a cross sectional study.

    PubMed

    Chandrasekaran, Vasanthi; Dilara, K; Padmavathi, R

    2014-01-01

    Tannery workers are at potential exposure to detrimental agents rendering them vulnerable to respiratory and dermal problems. Thus by performing pulmonary functions among leather tannery workers, we can decipher the effect of chromium and leather dust on lung functions and also the decline of respiratory functions with increasing years of exposure to leather dust. Pulmonary functions were assessed for 130 tannery workers and compared with the 130 unexposed office workers. Pulmonary function measurements namely FVC, FEV1, FEF25-75% and PEFR were measured using portable data logging Spirometer (KOKO Spirometer). The observed pulmonary functions of Tannery-workers in this study showed a reduction in FEV1, FVC, FEV1/FVC ratio, FEF25-75 and PEFR in relation to their predicted values and also compared to the unexposed. Smokers showed a decline in pulmonary functions compared to the non smokers because smoking acts as an additional risk factor in the development of respiratory illnesses. It is worthy to mention that the pulmonary function values correlate negatively with the duration of exposure to leather dust. So this study could provide base line information based upon which legal implementation of preventive measures could be undertaken.

  19. Comparison of peripapillary retinal nerve fiber layer loss and visual outcome in fellow eyes following sequential bilateral non-arteritic anterior ischemic optic neuropathy.

    PubMed

    Dotan, Gad; Kesler, Anat; Naftaliev, Elvira; Skarf, Barry

    2015-05-01

    To report on the correlation of structural damage to the axons of the optic nerve and visual outcome following bilateral non-arteritic anterior ischemic optic neuropathy. A retrospective review of the medical records of 25 patients with bilateral sequential non-arteritic anterior ischemic optic neuropathy was performed. Outcome measures were peripapillary retinal nerve fiber layer thickness measured with the Stratus optical coherence tomography scanner, visual acuity and visual field loss. Median peripapillary retinal nerve fiber layer (RNFL) thickness, mean deviation (MD) of visual field, and visual acuity of initially involved NAION eyes (54.00 µm, -17.77 decibels (dB), 0.4, respectively) were comparable to the same parameters measured following development of second NAION event in the other eye (53.70 µm, p = 0.740; -16.83 dB, p = 0.692; 0.4, p = 0.942, respectively). In patients with bilateral NAION, there was a significant correlation of peripapillary RNFL thickness (r = 0.583, p = 0.002) and MD of the visual field (r = 0.457, p = 0.042) for the pairs of affected eyes, whereas a poor correlation was found in visual acuity of these eyes (r = 0.279, p = 0.176). Peripapillary RNFL thickness following NAION was positively correlated with MD of visual field (r = 0.312, p = 0.043) and negatively correlated with logMAR visual acuity (r = -0.365, p = 0.009). In patients who experience bilateral NAION, the magnitude of RNFL loss is similar in each eye. There is a greater similarity in visual field loss than in visual acuity between the two affected eyes with NAION of the same individual.

  20. New vessels detected on wide-field imaging compared to two-field and seven-field imaging: implications for diabetic retinopathy screening image analysis.

    PubMed

    Talks, Stephen James; Manjunath, Vina; Steel, David H W; Peto, Tunde; Taylor, Roy

    2015-12-01

    Wide-field retinal imaging (Optomap), used for detecting diabetic retinopathy (DR), has been shown to compare well with seven-field early treatment diabetic retinopathy study (ETDRS) photographs. An Optomap 200° image covers 80% of the retinal surface, compared with the standard seven-field, 30° images, covering 30% of the retinal surface. In England, DR screening is performed by grading two, 45° images per eye, by the DR screening service (DRSS). To assess how often retinal new vessels (NVs) are observed on Optomap imaging, outside the DRSS two fields and standard seven-field photography, in a cohort of patients referred by the DRSS. A consecutive series of treatment naïve patients with DR, referred from DRSS with pre-proliferative or proliferative DR or diabetic maculopathy, were imaged with Optomap colour images, within 3 months of DRSS referral. The incidence and distribution of NVs were recorded in relation to two-field and seven-field areas. NVs were found in 102 of 1562 treatment naïve eyes (6.5%) of 781 patients. Of these, 72 were referred from DRSS as having NVs, but an additional 30 eyes (29% of NVs detected) from 25 patients were referred with a lesser degree of DR. In 25 of the 30 eyes without NVs reported on referral, NVs were located outside the standard two fields taken at DRSS, and in 12, NVs were outside the area covered on seven-field imaging (11.7% of eyes with NVs). Wide-field imaging with Optomap detected approximately 30% more NVs than standard two-field imaging in patients referred from a UK DRSS. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  1. Effects of lenses with different power profiles on eye shape in chickens.

    PubMed

    Tepelus, Tudor Cosmin; Vazquez, Daniel; Seidemann, Anne; Uttenweiler, Dietmar; Schaeffel, Frank

    2012-02-01

    Defocus imposed to the periphery of the visual field can affect the development of foveal/central refractive errors. To make use of this observation, lenses can be designed to reduce myopia progression, but it is important to know which power profiles of the lenses are most effective. We have studied this question in chickens. Sixty male white leghorn chickens were used. From day 7 after hatching, they were treated for 5 days either with full field -7D or +7D lenses, with -7D lenses with a 4mm central hole, with hemi-field lenses of the same power, or with two different types of radial refractive gradient (RRG) lenses with increasing positive power from the center to the periphery, which were designed by Rodenstock GmbH, Munich, Germany. A macro file was written for "ImageJ" to trace and average the outlines of several excised eyes after treatment. Shapes of fellow control eyes and lens-treated eyes were compared in the horizontal and vertical meridians. Refractions were determined at -45°, 0°, and 45° over the horizontal visual field, at the beginning and at the end of experiments, using automated infrared photoretinoscopy. (1) Eye length, as determined by the new automated eye shape tracing technique, was well correlated with A-scan ultrasound data. (2) The effects of previously tested lens designs were reproduced with the new tracing technique. Full field lenses were by far the most effective (-7D: external axial length +0.24mm with an increase in eye volume of about 6%, +7D: -0.08 mm, with a decrease in eye volume of about 2%). Hemi-field lenses and negative lenses with a 4mm central hole induced conspicuous local changes in eye shape. (3) The first type of RRG lenses with a plano zone of about 4mm (equivalent to about ± 12.52° in the visual field for a vertex distance of 5mm) had no apparent effect on central refractions but induced small hyperopic shifts in the periphery, more significant in the temporal retina (+1.70 ± 1.70 D, p<0.001, paired t-test to untreated fellow eyes). The second type of RRG lenses with a small plano zone of 2mm (equivalent to ± 6.34°) induced peripheral hyperopia but also changed the central refraction (temporal retina +1.50 ± 1.17D, p<0.001, central retina +0.77 ± 1.15 D, p<0.01, nasal retina +1.47±1.35D, p<0.001, paired t-test to untreated control eyes). In the afoveate chick, RRG lenses have an effect on central refraction and eye growth only if the central plano zone is small (<4mm). For the second type of RRG lens with a central plano zone of about 2mm, inhibitory effects on eye growth were detected in both the center and periphery even though the optical power of the lenses in the periphery was low. Copyright © 2011 Elsevier Ltd. All rights reserved.

  2. Acquisition of Cooperative Small Unmanned Aerial Systems for Advancing Man Machine Interface Research

    DTIC Science & Technology

    2016-08-24

    global sensor field of views (FOVs), mimicking biological systems such as an insect fly eye , but allowing multiple aperture configurations. Due to...synthetic, global sensor field of views (FOVs), mimicking biological systems such as an insect fly eye , but allowing multiple aperture configurations. Due to...such as an insect fly eye , but allowing multiple aperture configurations. Due to the desired nature of distributed networked aerial vehicles (for the

  3. Characteristics and Ophthalmic Manifestations of the Classic Dengue Fever Epidemic in Singapore (2005-2006).

    PubMed

    Koh, Yan Tong; Sanjay, Srinivasan

    2013-01-01

    The aim of this study was to report the characteristics and ophthalmic manifestations associated with dengue fever (DF) in the 2005-2006 DF epidemic in Singapore. A retrospective case series. Eleven patients (7 males, 4 females) who were 14 to 40 years old (mean age, 27.3 years) with visual complaints occurring 1 to 2 weeks after the onset of DF underwent a complete ophthalmologic examination. The presenting visual acuity (VA) ranged from 6/6 to counting fingers. Five patients had bilateral eye involvement. Ophthalmic findings included retinal hemorrhages (15 eyes), cotton wool spots (15 eyes), retinal pigment epithelium alterations (5 eyes), optic disc swelling (3 eyes), foveolitis (3 eyes), and hyperemia (2 eyes). Impaired color vision was noted in 12 eyes. Visual field defects were noted in 13 eyes; 4 of these eyes were asymptomatic. Fundus fluorescein angiography was done in 9 patients; the findings include choroidal hyperfluorescence (9 eyes), blocked fluorescence (8 eyes), and capillary nonperfusion (1 eye). In 2 eyes, it was normal. Electrophysiology confirmed optic neuropathy in 3 eyes and maculopathy in 1 eye. The follow-up ranged from 12 days to 12 months. The VA at the last follow-up ranged from no light perception to 6/6. Visual field abnormalities were noted in 5 eyes despite a normal VA. Dengue fever is associated with a wide spectrum of ophthalmic manifestations. Rarely, ophthalmic complications in DF can result in permanent visual impairment. Further work can be done to elucidate the relationship between systemic and ocular manifestations of DF.

  4. SU-G-IeP4-09: Method of Human Eye Aberration Measurement Using Plenoptic Camera Over Large Field of View

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lv, Yang; Wang, Ruixing; Ma, Haotong

    Purpose: The measurement based on Shack-Hartmann wave-front sensor(WFS), obtaining both the high and low order wave-front aberrations simultaneously and accurately, has been applied in the detection of human eyes aberration in recent years. However, Its application is limited by the small field of view (FOV), slight eye movement leads the optical bacon image exceeds the lenslet array which result in uncertain detection error. To overcome difficulties of precise eye location, the capacity of detecting eye wave-front aberration over FOV much larger than simply a single conjugate Hartmann WFS accurately and simultaneously is demanded. Methods: Plenoptic camera’s lenslet array subdivides themore » aperture light-field in spatial frequency domain, capture the 4-D light-field information. Data recorded by plenoptic cameras can be used to extract the wave-front phases associated to the eyes aberration. The corresponding theoretical model and simulation system is built up in this article to discuss wave-front measurement performance when utilizing plenoptic camera as wave-front sensor. Results: The simulation results indicate that the plenoptic wave-front method can obtain both the high and low order eyes wave-front aberration with the same accuracy as conventional system in single visual angle detectionand over FOV much larger than simply a single conjugate Hartmann systems. Meanwhile, simulation results show that detection of eye aberrations wave-front in different visual angle can be achieved effectively and simultaneously by plenoptic method, by both point and extended optical beacon from the eye. Conclusion: Plenoptic wave-front method possesses the feasibility in eye aberrations wave-front detection. With larger FOV, the method can effectively reduce the detection error brought by imprecise eye location and simplify the eye aberrations wave-front detection system comparing with which based on Shack-Hartmann WFS. Unique advantage of the plenoptic method lies in obtaining wave-front in different visual angle simultaneously, which provides an approach in building up 3-D model of eye refractor tomographically. Funded by the key Laboratory of High Power Laser and Physics, CAS Research Project of National University of Defense Technology No. JC13-07-01; National Natural Science Foundation of China No. 61205144.« less

  5. BMP signaling protects telencephalic fate by repressing eye identity and its Cxcr4-dependent morphogenesis.

    PubMed

    Bielen, Holger; Houart, Corinne

    2012-10-16

    Depletion of Wnt signaling is a major requirement for the induction of the anterior prosencephalon. However, the molecular events driving the differential regionalization of this area into eye-field and telencephalon fates are still unknown. Here we show that the BMP pathway is active in the anterior neural ectoderm during late blastula to early gastrula stage in zebrafish. Bmp2b mutants and mosaic loss-of-function experiments reveal that BMP acts as a repressor of eye-field fate through inhibition of its key transcription factor Rx3, thereby protecting the future telencephalon from acquiring eye identity. This BMP-driven mechanism initiates the establishment of the telencephalon prior to the involvement of Wnt antagonists from the anterior neural border. Furthermore, we demonstrate that Rx3 and BMP are respectively required to maintain and restrict the chemokine receptor cxcr4a, which in turn contributes to the morphogenetic separation of eye-field and telencephalic cells during early neurulation. Copyright © 2012 Elsevier Inc. All rights reserved.

  6. Ultra-Wide Field Imaging in Paradoxical Worsening of Tubercular Multifocal Serpiginoid Choroiditis after the Initiation of Anti-Tubercular Therapy.

    PubMed

    Aggarwal, Kanika; Agarwal, Aniruddha; Deokar, Ankit; Singh, Ramandeep; Bansal, Reema; Sharma, Aman; Sharma, Kusum; Dogra, Mangat R; Gupta, Vishali

    2017-10-11

    To evaluate role of ultra-wide field (UWF) versus conventional imaging in the follow-up and paradoxical worsening (PW) of tubercular (TB) multifocal serpiginoid choroiditis (MSC). Prospective observational study of patients with TB MSC undergoing UWF imaging, autofluorescence and fluorescein angiography was performed. A circle simulating central 75° field representing conventional imaging was drawn on UWF images. The information yielded by the two modalities, progression of choroiditis lesions and PW was compared. 44 eyes (29 patients, mean age: 30.7 ± 9 years; 23 males) were included. UWF imaging showed additional lesions in 39/44 eyes (88.6%). Overall, 16/44 eyes (36.4%) showed PW; 3/16 eyes (18.7%) showed only peripheral PW, while 10/16 eyes showed both central and peripheral PW. Management was altered in 11 patients (37.93%) based on UWF imaging. UWF is more useful than conventional imaging in identifying additional choroiditis lesions, PW and altering the course of therapy in TB MSC.

  7. Underwater binocular imaging of aerial objects versus the position of eyes relative to the flat water surface.

    PubMed

    Barta, András; Horváth, Gábor

    2003-12-01

    The apparent position, size, and shape of aerial objects viewed binocularly from water change as a result of the refraction of light at the water surface. Earlier studies of the refraction-distorted structure of the aerial binocular visual field of underwater observers were restricted to either vertically or horizontally oriented eyes. Here we calculate the position of the binocular image point of an aerial object point viewed by two arbitrarily positioned underwater eyes when the water surface is flat. Assuming that binocular image fusion is performed by appropriate vergent eye movements to bring the object's image onto the foveae, the structure of the aerial binocular visual field is computed and visualized as a function of the relative positions of the eyes. We also analyze two erroneous representations of the underwater imaging of aerial objects that have occurred in the literature. It is demonstrated that the structure of the aerial binocular visual field of underwater observers distorted by refraction is more complex than has been thought previously.

  8. Comparison between wide-angle OCT angiography and ultra-wide field fluorescein angiography for detecting non-perfusion areas and retinal neovascularization in eyes with diabetic retinopathy.

    PubMed

    Sawada, Osamu; Ichiyama, Yusuke; Obata, Syunpei; Ito, Yuka; Kakinoki, Masashi; Sawada, Tomoko; Saishin, Yoshitsugu; Ohji, Masahito

    2018-04-30

    To compare the ability of wide-angle optical coherence tomography angiography (OCTA) with that of ultra-wide field fluorescein angiography (UWFFA) to detect non-perfusion areas (NPAs) or retinal neovascularization (NV) in eyes with diabetic retinopathy (DR). Patients with DR underwent UWFFA using the Optos® panoramic 200Tx imaging system and wide-angle OCTA with 12 × 12 mm fields of five visual fixations using the PLEX Elite 9000®. We compared the abilities of UWFFA and OCTA to detect NPAs and NV. Fifty-eight eyes of 33 patients (mean age, 60.0 years old; female/male, 16/17) with DR were evaluated. NPAs were detected in 47 out of 58 eyes using UWFFA and in 48 eyes using OCTA. NVs were detected in 25 out of the 58 eyes using UWFFA and in 26 eyes using OCTA. The sensitivity for detection of NPA using OCTA was 0.98, and the specificity was 0.82. The sensitivity for detection of NV was 1.0, and the specificity was 0.97. The wide-angle OCTA seems to be clinically useful for the detection of NPAs or NV.

  9. Progression of visual field in patients with primary open-angle glaucoma - ProgF study 1.

    PubMed

    Aptel, Florent; Aryal-Charles, Nishal; Giraud, Jean-Marie; El Chehab, Hussam; Delbarre, Maxime; Chiquet, Christophe; Romanet, Jean-Paul; Renard, Jean-Paul

    2015-12-01

    To evaluate the visual field rate of progression of patients with treated ocular hypertension (OHT) and primary open-angle glaucoma (POAG) in clinical practice, using the mean deviation (MD) and the visual field index (VFI). Non-interventional cohort study. From a large multicentre database representative of the French population, 441 eyes of 228 patients with treated OHT or POAG followed up at least 6 years with Humphrey 24.2 Sita-Standard visual field examination at least twice a year were identified. From initial data, eyes were classified in five groups: 121 with OHT, 188 with early glaucoma (MD greater than -6 dB), 45 with moderate glaucoma (MD -6 to -12 dB), 41 with advanced glaucoma (MD -12 to -18 dB) and 46 with severe glaucoma (MD less than -18 dB). Rate of progression during the follow-up period was calculated using the trend analysis of the Guided Progression Analysis software. The mean duration of follow-up was 8.4 ± 2.7 years and the mean number of visual field, 18.4 ± 3.5. In eyes with OHT, rate of progression was -0.09 dB/year (-0.17%VFI/year). In eyes with POAG, rate of progression was -0.32 dB/year (-0.83%VFI/year) in eyes with early glaucoma, -0.52 dB/year (-1.81%VFI/year) in moderate glaucoma, -0.54 dB/year (-2.35%VFI/year) in advanced glaucoma and -0.45 dB/year (-1.97%VFI/year) in severe glaucoma. In eyes with POAG, a significant progression (p < 0.05) was detected in 159 of 320 eyes (49.7%) with trend analysis and 117 of 320 eyes (36.6%, likely progression) or 183 of 320 eyes (57.2%, possible and likely progression) with event analysis. Primary open-angle glaucoma is a progressive disease in the majority of patients despite cautioned treatment and follow-up. The rate of progression varies greatly among subjects. © 2015 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  10. [Features associated with retinal thickness extension in diabetic macular oedema].

    PubMed

    Razo Blanco-Hernández, Dulce Milagros; Lima-Gómez, Virgilio; García-Rubio, Yatzul Zuhaila

    2015-01-01

    Clinically significant macular edema has features that are associated with a major risk of visual loss, with thickening that involves the centre of the macula, field 7 or visual deficiency, although it is unknown if these features are related to retinal thickness extension. An observational, analytical, prospective, cross-sectional and open study was conducted. The sample was divided into initial visual acuity ≥0.5, central field thickness, center point thickness, field 7 and macular volume more than the reported 2 standard deviation mean value in eyes without retinopathy. The extension was determined by the number of the central field area equivalent thickening and these features were compared with by Student's t test for independent samples. A total of 199 eyes were included. In eyes with visual acuity of ≥0.5, the mean extension was 2.88±1.68 and 3.2±1.63 in area equivalent in eyes with visual acuity <0.5 (p=0.12). The mean extension in eyes with less than 2 standard deviation of central field thickness, center point thickness, field 7 and macular volume was significantly lower than in eyes with more than 2 standard deviations (1.9±0.93 vs. 4.07±1.49, 2.44±1.47 vs. 3.94±1.52, 1.79±1.07 vs. 3.61±1.57 and 1.6±0.9 vs. 3.9±1.4, respectively, p<0.001). The extension of retinal thickness is related with the anatomical features reported with a greater risk of visual loss, but is not related to initial visual deficiency. Copyright © 2015 Academia Mexicana de Cirugía A.C. Published by Masson Doyma México S.A. All rights reserved.

  11. Acquired color vision and visual field defects in patients with ocular hypertension and early glaucoma

    PubMed Central

    Papaconstantinou, Dimitris; Georgalas, Ilias; Kalantzis, George; Karmiris, Efthimios; Koutsandrea, Chrysanthi; Diagourtas, Andreas; Ladas, Ioannis; Georgopoulos, Gerasimos

    2009-01-01

    Purpose: To study acquired color vision and visual field defects in patients with ocular hypertension (OH) and early glaucoma. Methods: In a prospective study we evaluated 99 eyes of 56 patients with OH without visual field defects and no hereditary color deficiencies, followed up for 4 to 6 years (mean = 4.7 ± 0.6 years). Color vision defects were studied using a special computer program for Farnsworth–Munsell 100 hue test and visual field tests were performed with Humphrey analyzer using program 30–2. Both tests were repeated every six months. Results: In fifty-six eyes, glaucomatous defects were observed during the follow-up period. There was a statistically significant difference in total error score (TES) between eyes that eventually developed glaucoma (157.89 ± 31.79) and OH eyes (75.51 ± 31.57) at the first examination (t value 12.816, p < 0.001). At the same time visual field indices were within normal limits in both groups. In the glaucomatous eyes the earliest statistical significant change in TES was identified at the first year of follow-up and was −20.62 ± 2.75 (t value 9.08, p < 0.001) while in OH eyes was −2.11 ± 4.36 (t value 1.1, p = 0.276). Pearson’s coefficient was high in all examinations and showed a direct correlation between TES and mean deviation and corrected pattern standard deviation in both groups. Conclusion: Quantitative analysis of color vision defects provides the possibility of follow-up and can prove a useful means for detecting early glaucomatous changes in patients with normal visual fields. PMID:19668575

  12. Tutorial on Biostatistics: Linear Regression Analysis of Continuous Correlated Eye Data

    PubMed Central

    Ying, Gui-shuang; Maguire, Maureen G; Glynn, Robert; Rosner, Bernard

    2017-01-01

    Purpose To describe and demonstrate appropriate linear regression methods for analyzing correlated continuous eye data. Methods We describe several approaches to regression analysis involving both eyes, including mixed effects and marginal models under various covariance structures to account for inter-eye correlation. We demonstrate, with SAS statistical software, applications in a study comparing baseline refractive error between one eye with choroidal neovascularization (CNV) and the unaffected fellow eye, and in a study determining factors associated with visual field data in the elderly. Results When refractive error from both eyes were analyzed with standard linear regression without accounting for inter-eye correlation (adjusting for demographic and ocular covariates), the difference between eyes with CNV and fellow eyes was 0.15 diopters (D; 95% confidence interval, CI −0.03 to 0.32D, P=0.10). Using a mixed effects model or a marginal model, the estimated difference was the same but with narrower 95% CI (0.01 to 0.28D, P=0.03). Standard regression for visual field data from both eyes provided biased estimates of standard error (generally underestimated) and smaller P-values, while analysis of the worse eye provided larger P-values than mixed effects models and marginal models. Conclusion In research involving both eyes, ignoring inter-eye correlation can lead to invalid inferences. Analysis using only right or left eyes is valid, but decreases power. Worse-eye analysis can provide less power and biased estimates of effect. Mixed effects or marginal models using the eye as the unit of analysis should be used to appropriately account for inter-eye correlation and maximize power and precision. PMID:28102741

  13. 45 CFR 233.70 - Blindness.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... visual acuity of 20/200 or less in the better eye with correcting glasses or a field defect in which the... diseases of the eye or by an optometrist, whichever the individual so selects. (i) No examination is necessary when both eyes are missing. (ii) Where an initial eye examination or re-examination is necessary...

  14. 45 CFR 233.70 - Blindness.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... visual acuity of 20/200 or less in the better eye with correcting glasses or a field defect in which the... diseases of the eye or by an optometrist, whichever the individual so selects. (i) No examination is necessary when both eyes are missing. (ii) Where an initial eye examination or re-examination is necessary...

  15. Testing of Visual Field with Virtual Reality Goggles in Manual and Visual Grasp Modes

    PubMed Central

    Wroblewski, Dariusz; Francis, Brian A.; Sadun, Alfredo; Vakili, Ghazal; Chopra, Vikas

    2014-01-01

    Automated perimetry is used for the assessment of visual function in a variety of ophthalmic and neurologic diseases. We report development and clinical testing of a compact, head-mounted, and eye-tracking perimeter (VirtualEye) that provides a more comfortable test environment than the standard instrumentation. VirtualEye performs the equivalent of a full threshold 24-2 visual field in two modes: (1) manual, with patient response registered with a mouse click, and (2) visual grasp, where the eye tracker senses change in gaze direction as evidence of target acquisition. 59 patients successfully completed the test in manual mode and 40 in visual grasp mode, with 59 undergoing the standard Humphrey field analyzer (HFA) testing. Large visual field defects were reliably detected by VirtualEye. Point-by-point comparison between the results obtained with the different modalities indicates: (1) minimal systematic differences between measurements taken in visual grasp and manual modes, (2) the average standard deviation of the difference distributions of about 5 dB, and (3) a systematic shift (of 4–6 dB) to lower sensitivities for VirtualEye device, observed mostly in high dB range. The usability survey suggested patients' acceptance of the head-mounted device. The study appears to validate the concepts of a head-mounted perimeter and the visual grasp mode. PMID:25050326

  16. Eyes in the sky. Interactions between asymptotic giant branch star winds and the interstellar magnetic field

    NASA Astrophysics Data System (ADS)

    van Marle, A. J.; Cox, N. L. J.; Decin, L.

    2014-10-01

    Context. The extended circumstellar envelopes (CSEs) of evolved low-mass stars display a large variety of morphologies. Understanding the various mechanisms that give rise to these extended structures is important to trace their mass-loss history. Aims: Here, we aim to examine the role of the interstellar magnetic field in shaping the extended morphologies of slow dusty winds of asymptotic giant branch (AGB) stars in an effort to pin-point the origin of so-called eye shaped CSEs of three carbon-rich AGB stars. In addition, we seek to understand if this pre-planetary nebula (PN) shaping can be responsible for asymmetries observed in PNe. Methods: Hydrodynamical simulations are used to study the effect of typical interstellar magnetic fields on the free-expanding spherical stellar winds as they sweep up the local interstellar medium (ISM). Results: The simulations show that typical Galactic interstellar magnetic fields of 5 to 10 μG are sufficient to alter the spherical expanding shells of AGB stars to appear as the characteristic eye shape revealed by far-infrared observations. The typical sizes of the simulated eyes are in accordance with the observed physical sizes. However, the eye shapes are transient in nature. Depending on the stellar and interstellar conditions, they develop after 20 000 to 200 000 yrs and last for about 50 000 to 500 000 yrs, assuming that the star is at rest relative to the local interstellar medium. Once formed, the eye shape develops lateral outflows parallel to the magnetic field. The explosion of a PN in the centre of the eye-shaped dust shell gives rise to an asymmetrical nebula with prominent inward pointing Rayleigh-Taylor instabilities. Conclusions: Interstellar magnetic fields can clearly affect the shaping of wind-ISM interaction shells. The occurrence of the eyes is most strongly influenced by stellar space motion and ISM density. Observability of this transient phase is favoured for lines-of-sight perpendicular to the interstellar magnetic field direction. The simulations indicate that shaping of the pre-PN envelope can strongly affect the shape and size of PNe. Herschel is an ESA space observatory with science instruments provided by European-led Principal Investigator consortia and with important participation from NASA.Movies are available in electronic form at http://www.aanda.org

  17. Bio-inspired hemispherical compound eye camera

    NASA Astrophysics Data System (ADS)

    Xiao, Jianliang; Song, Young Min; Xie, Yizhu; Malyarchuk, Viktor; Jung, Inhwa; Choi, Ki-Joong; Liu, Zhuangjian; Park, Hyunsung; Lu, Chaofeng; Kim, Rak-Hwan; Li, Rui; Crozier, Kenneth B.; Huang, Yonggang; Rogers, John A.

    2014-03-01

    Compound eyes in arthropods demonstrate distinct imaging characteristics from human eyes, with wide angle field of view, low aberrations, high acuity to motion and infinite depth of field. Artificial imaging systems with similar geometries and properties are of great interest for many applications. However, the challenges in building such systems with hemispherical, compound apposition layouts cannot be met through established planar sensor technologies and conventional optics. We present our recent progress in combining optics, materials, mechanics and integration schemes to build fully functional artificial compound eye cameras. Nearly full hemispherical shapes (about 160 degrees) with densely packed artificial ommatidia were realized. The number of ommatidia (180) is comparable to those of the eyes of fire ants and bark beetles. The devices combine elastomeric compound optical elements with deformable arrays of thin silicon photodetectors, which were fabricated in the planar geometries and then integrated and elastically transformed to hemispherical shapes. Imaging results and quantitative ray-tracing-based simulations illustrate key features of operation. These general strategies seem to be applicable to other compound eye devices, such as those inspired by moths and lacewings (refracting superposition eyes), lobster and shrimp (reflecting superposition eyes), and houseflies (neural superposition eyes).

  18. Eye injuries from electrical weapon probes: Incidents, prevalence, and legal implications.

    PubMed

    Kroll, Mark W; Ritter, Mollie B; Kennedy, Eric A; Silverman, Nora K; Shinder, Roman; Brave, Michael A; Williams, Howard E

    2018-04-01

    While generally reducing morbidity and mortality, electrical weapons have risks associated with their usage, including burn injuries and trauma associated with uncontrolled fall impacts. However, the prevalence of significant eye injury has not been investigated. We searched for incidents of penetrating eye injury from TASER ® conducted electrical weapon (CEW) probes via open source media, litigation filings, and a survey of CEW law-enforcement master instructors. We report 20 previously-unpublished cases of penetrating eye injury from electrical weapon probes in law-enforcement field uses. Together with the 8 previously published cases, there are a total of 28 cases out of 3.44 million field uses, giving a demonstrated CEW field-use risk of penetrating eye injury of approximately 1:123 000. Confidence limits [85 000, 178 000] by Wilson score interval. There have been 18 cases of total unilateral blindness or enucleation. We also present legal decisions on this topic. The use of electrical weapons presents a rare but real risk of total or partial unilateral blindness from electrical weapon probes. Catastrophic eye injuries appear to be the dominant non-fatal complication of electronic control. Copyright © 2018 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  19. Objective estimation of tropical cyclone innercore surface wind structure using infrared satellite images

    NASA Astrophysics Data System (ADS)

    Zhang, Changjiang; Dai, Lijie; Ma, Leiming; Qian, Jinfang; Yang, Bo

    2017-10-01

    An objective technique is presented for estimating tropical cyclone (TC) innercore two-dimensional (2-D) surface wind field structure using infrared satellite imagery and machine learning. For a TC with eye, the eye contour is first segmented by a geodesic active contour model, based on which the eye circumference is obtained as the TC eye size. A mathematical model is then established between the eye size and the radius of maximum wind obtained from the past official TC report to derive the 2-D surface wind field within the TC eye. Meanwhile, the composite information about the latitude of TC center, surface maximum wind speed, TC age, and critical wind radii of 34- and 50-kt winds can be combined to build another mathematical model for deriving the innercore wind structure. After that, least squares support vector machine (LSSVM), radial basis function neural network (RBFNN), and linear regression are introduced, respectively, in the two mathematical models, which are then tested with sensitivity experiments on real TC cases. Verification shows that the innercore 2-D surface wind field structure estimated by LSSVM is better than that of RBFNN and linear regression.

  20. Cupping reversal in pediatric glaucoma--evaluation of the retinal nerve fiber layer and visual field.

    PubMed

    Ely, Amanda L; El-Dairi, Mays A; Freedman, Sharon F

    2014-11-01

    To identify optic nerve head (ONH) cupping reversal and associated optical coherence tomography (OCT) and Humphrey visual field changes in pediatric glaucoma. Retrospective observational case series. Sequential surgical cases of juvenile open-angle glaucoma (OAG) or primary congenital glaucoma (PCG) with sustained postoperative intraocular pressure (IOP) reduction. Group 1 had preoperative and postoperative ONH photographs and OCT; Group 2 had preoperative clinical ONH assessment and postoperative imaging. Cupping evaluation was confirmed by masked glaucoma and neuro-ophthalmology specialists. Of 80 cases, 9 eyes (9 children) met criteria for Group 1; 24 eyes (19 children) met criteria for Group 2. Group 1: Five of 9 eyes (56%) demonstrated cupping reversal, with preoperative vs postoperative mean IOP 34.2 ± 6.6 mm Hg vs 10.6 ± 4.1 mm Hg (P < .00001) and mean average retinal nerve fiber layer (RNFL) 71.0 ± 30 μm vs 62.8 ± 24 μm (P = .4), respectively. RNFL was stable in 4 of 5 eyes (all juvenile OAG), but thinned (Δ = -41 μm) in 1 eye with PCG. Humphrey visual fields (reliable in 2 of 3 eyes) showed no significant change. Group 2: Fourteen of 24 PCG eyes (58%) demonstrated cupping reversal, with preoperative vs postoperative mean IOP 36.1 ± 8.9 mm Hg vs 13.3 ± 2.1 mm Hg (P < .00001). Two eyes had thin RNFL postoperatively despite healthy-appearing ONH. Postoperative RNFL showed statistically significant linear correlation with preoperative (but not postoperative) cup-to-disc ratio. Limitations include small numbers, few reliable Humphrey visual fields, and absent preoperative imaging (Group 2). Some eyes with IOP reduction and ONH cupping reversal show continued RNFL thinning postoperatively. The preoperative ONH cup-to-disc ratio predicted the postoperative RNFL better than the postoperative "reversed and smaller" cup-to-disc ratio. Cupping reversal in pediatric glaucoma may not predict improved ONH health and deserves further study. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. Progression of Patterns (POP): A Machine Classifier Algorithm to Identify Glaucoma Progression in Visual Fields

    PubMed Central

    Goldbaum, Michael H.; Lee, Intae; Jang, Giljin; Balasubramanian, Madhusudhanan; Sample, Pamela A.; Weinreb, Robert N.; Liebmann, Jeffrey M.; Girkin, Christopher A.; Anderson, Douglas R.; Zangwill, Linda M.; Fredette, Marie-Josee; Jung, Tzyy-Ping; Medeiros, Felipe A.; Bowd, Christopher

    2012-01-01

    Purpose. We evaluated Progression of Patterns (POP) for its ability to identify progression of glaucomatous visual field (VF) defects. Methods. POP uses variational Bayesian independent component mixture model (VIM), a machine learning classifier (MLC) developed previously. VIM separated Swedish Interactive Thresholding Algorithm (SITA) VFs from a set of 2,085 normal and glaucomatous eyes into nine axes (VF patterns): seven glaucomatous. Stable glaucoma was simulated in a second set of 55 patient eyes with five VFs each, collected within four weeks. A third set of 628 eyes with 4,186 VFs (mean ± SD of 6.7 ± 1.7 VFs over 4.0 ± 1.4 years) was tested for progression. Tested eyes were placed into suspect and glaucoma categories at baseline, based on VFs and disk stereoscopic photographs; a subset of eyes had stereophotographic evidence of progressive glaucomatous optic neuropathy (PGON). Each sequence of fields was projected along seven VIM glaucoma axes. Linear regression (LR) slopes generated from projections onto each axis yielded a degree of confidence (DOC) that there was progression. At 95% specificity, progression cutoffs were established for POP, visual field index (VFI), and mean deviation (MD). Guided progression analysis (GPA) was also compared. Results. POP identified a statistically similar number of eyes (P > 0.05) as progressing compared with VFI, MD, and GPA in suspects (3.8%, 2.7%, 5.6%, and 2.9%, respectively), and more eyes than GPA (P = 0.01) in glaucoma (16.0%, 15.3%, 12.0%, and 7.3%, respectively), and more eyes than GPA (P = 0.05) in PGON eyes (26.3%, 23.7%, 27.6%, and 14.5%, respectively). Conclusions. POP, with its display of DOC of progression and its identification of progressing VF defect pattern, adds to the information available to the clinician for detecting VF progression. PMID:22786913

  2. Disease Course of Patients with Unilateral Pigmentary Retinopathy

    PubMed Central

    Potsidis, Emorfily; Berson, Eliot L.

    2011-01-01

    Purpose. To evaluate the change in ocular function by eye in patients with unilateral pigmentary retinopathy. Methods. Longitudinal regression was used to estimate mean exponential rates of change in Goldmann visual field area (V4e white test light) and in full-field electroretinogram (ERG) amplitudes to 0.5- and 30-Hz white flashes in 15 patients with unilateral pigmentary retinopathy. Snellen visual acuity was assessed case by case. Results. Mean annual rates of change for the affected eyes were −4.9% for visual field area, −4.7% for ERG amplitude to 0.5-Hz flashes, and −4.6% for ERG amplitude to 30-Hz flashes. All three rates were faster than the corresponding age-related rates of change for the fellow normal eyes (P = 0.0006, P = 0.003, P = 0.03, respectively). An initial cone ERG implicit time to 30-Hz flashes in affected eyes ≥40 ms predicted a faster mean rate of decline of visual field area and of ERG amplitude to 0.5- and 30-Hz flashes (P < 0.0001 for all three measures). The visual acuity of affected eyes was more likely to decrease in patients presenting at >35 years of age than in patients presenting at a younger age (P = 0.0004). Conclusions. The affected eye in unilateral pigmentary retinopathy shows a progressive loss of peripheral retinal function that cannot be attributed to aging alone and that is faster in eyes with a more prolonged initial cone ERG implicit time. Patients presenting at >35 years of age are at greater risk for losing visual acuity. PMID:21989720

  3. Disease course of patients with unilateral pigmentary retinopathy.

    PubMed

    Potsidis, Emorfily; Berson, Eliot L; Sandberg, Michael A

    2011-11-29

    To evaluate the change in ocular function by eye in patients with unilateral pigmentary retinopathy. Longitudinal regression was used to estimate mean exponential rates of change in Goldmann visual field area (V4e white test light) and in full-field electroretinogram (ERG) amplitudes to 0.5- and 30-Hz white flashes in 15 patients with unilateral pigmentary retinopathy. Snellen visual acuity was assessed case by case. Mean annual rates of change for the affected eyes were -4.9% for visual field area, -4.7% for ERG amplitude to 0.5-Hz flashes, and -4.6% for ERG amplitude to 30-Hz flashes. All three rates were faster than the corresponding age-related rates of change for the fellow normal eyes (P = 0.0006, P = 0.003, P = 0.03, respectively). An initial cone ERG implicit time to 30-Hz flashes in affected eyes ≥ 40 ms predicted a faster mean rate of decline of visual field area and of ERG amplitude to 0.5- and 30-Hz flashes (P < 0.0001 for all three measures). The visual acuity of affected eyes was more likely to decrease in patients presenting at >35 years of age than in patients presenting at a younger age (P = 0.0004). The affected eye in unilateral pigmentary retinopathy shows a progressive loss of peripheral retinal function that cannot be attributed to aging alone and that is faster in eyes with a more prolonged initial cone ERG implicit time. Patients presenting at >35 years of age are at greater risk for losing visual acuity.

  4. Differences between Non-arteritic Anterior Ischemic Optic Neuropathy and Open Angle Glaucoma with Altitudinal Visual Field Defect.

    PubMed

    Han, Sangyoun; Jung, Jong Jin; Kim, Ungsoo Samuel

    2015-12-01

    To investigate the differences in retinal nerve fiber layer (RNFL) change and optic nerve head parameters between non-arteritic anterior ischemic optic neuropathy (NAION) and open angle glaucoma (OAG) with altitudinal visual field defect. Seventeen NAION patients and 26 OAG patients were enrolled prospectively. The standard visual field indices (mean deviation, pattern standard deviation) were obtained from the Humphrey visual field test and differences between the two groups were analyzed. Cirrus HD-OCT parameters were used, including optic disc head analysis, average RNFL thickness, and RNFL thickness of each quadrant. The mean deviation and pattern standard deviation were not significantly different between the groups. In the affected eye, although the disc area was similar between the two groups (2.00 ± 0.32 and 1.99 ± 0.33 mm(2), p = 0.586), the rim area of the OAG group was smaller than that of the NAION group (1.26 ± 0.56 and 0.61 ± 0.15 mm(2), respectively, p < 0.001). RNFL asymmetry was not different between the two groups (p = 0.265), but the inferior RNFL thickness of both the affected and unaffected eyes were less in the OAG group than in the NAION group. In the analysis of optic disc morphology, both affected and unaffected eyes showed significant differences between two groups. To differentiate NAION from OAG in eyes with altitudinal visual field defects, optic disc head analysis of not only the affected eye, but also the unaffected eye, by using spectral domain optical coherence tomography may be helpful.

  5. Fellow Eye Changes in Patients with Nonischemic Central Retinal Vein Occlusion: Assessment of Perfused Foveal Microvascular Density and Identification of Nonperfused Capillaries

    PubMed Central

    Pinhas, Alexander; Dubow, Michael; Shah, Nishit; Cheang, Eric; Liu, Chun L.; Razeen, Moataz; Gan, Alexander; Weitz, Rishard; Sulai, Yusufu N.; Chui, Toco Y.; Dubra, Alfredo; Rosen, Richard B.

    2016-01-01

    Purpose Eyes fellow to nonischemic central retinal vein occlusion (CRVO) were examined for abnormalities, which might explain their increased risk for future occlusion, using adaptive optics scanning light ophthalmoscope fluorescein angiography. Methods Adaptive optics scanning light ophthalmoscope fluorescein angiography foveal microvascular densities were calculated. Nonperfused capillaries adjacent to the foveal avascular zone were identified. Spectral domain optical coherence tomography, ultrawide field fluorescein angiographies, and microperimetry were also performed. Results Ten fellow eyes of nine nonischemic CRVO and 1 nonischemic hemi-CRVO subjects and four affected eyes of three nonischemic CRVO and one nonischemic hemi-CRVO subjects were imaged. Ninety percent of fellow eyes and 100% of affected eyes demonstrated at least 1 nonperfused capillary compared with 31% of healthy eyes. Fellow eye microvascular density (35 ± 3.6 mm−1) was significantly higher than that of affected eyes (25 ± 5.2 mm−1) and significantly lower than that of healthy eyes (42 ± 4.2 mm−1). Compared with healthy controls, spectral domain optical coherence tomography thicknesses showed no significant difference, whereas microperimetry and 2/9 ultrawide field fluorescein angiography revealed abnormalities in fellow eyes. Conclusion Fellow eye changes detectable on adaptive optics scanning light ophthalmoscope fluorescein angiography reflect subclinical pathology difficult to detect using conventional imaging technologies. These changes may help elucidate the pathogenesis of nonischemic CRVO and help identify eyes at increased risk of future occlusion. PMID:25932560

  6. A unified dynamic neural field model of goal directed eye movements

    NASA Astrophysics Data System (ADS)

    Quinton, J. C.; Goffart, L.

    2018-01-01

    Primates heavily rely on their visual system, which exploits signals of graded precision based on the eccentricity of the target in the visual field. The interactions with the environment involve actively selecting and focusing on visual targets or regions of interest, instead of contemplating an omnidirectional visual flow. Eye-movements specifically allow foveating targets and track their motion. Once a target is brought within the central visual field, eye-movements are usually classified into catch-up saccades (jumping from one orientation or fixation to another) and smooth pursuit (continuously tracking a target with low velocity). Building on existing dynamic neural field equations, we introduce a novel model that incorporates internal projections to better estimate the current target location (associated to a peak of activity). Such estimate is then used to trigger an eye movement, leading to qualitatively different behaviours depending on the dynamics of the whole oculomotor system: (1) fixational eye-movements due to small variations in the weights of projections when the target is stationary, (2) interceptive and catch-up saccades when peaks build and relax on the neural field, (3) smooth pursuit when the peak stabilises near the centre of the field, the system reaching a fixed point attractor. Learning is nevertheless required for tracking a rapidly moving target, and the proposed model thus replicates recent results in the monkey, in which repeated exercise permits the maintenance of the target within in the central visual field at its current (here-and-now) location, despite the delays involved in transmitting retinal signals to the oculomotor neurons.

  7. Robinia pseudoacacia (black locust) as day-roosts of male Myotis septentrionalis (northern Bats) on the Fernow Experimental Forest, West Virginia

    Treesearch

    W. Mark Ford; Sheldon F. Owen; John W. Edwards; Jane L. Rodrigue

    2006-01-01

    During the summer of 2003, we captured and radiotagged ten male Myotis septentrionalis (northern bats) on the Fernow Experimental Forest (FEF) in the Allegheny Mountains of West Virginia to investigate day-roost selection. Of 16 roosts that were located, 13 were in Robinia pseudoacacia (black locusts), five in snags and eight in...

  8. Improvement in conduction velocity after optic neuritis measured with the multifocal VEP.

    PubMed

    Yang, E Bo; Hood, Donald C; Rodarte, Chris; Zhang, Xian; Odel, Jeffrey G; Behrens, Myles M

    2007-02-01

    To test the efficacy of the multifocal visual evoked potential (mfVEP) technique after long-term latency changes in optic neuritis (ON)/multiple sclerosis (MS), mfVEPs were recorded in 12 patients with ON/MS. Sixty local VEP responses were recorded simultaneously. mfVEP was recorded from both eyes of 12 patients with ON/MS. Patients were tested twice after recovery from acute ON episodes, which occurred in 14 of the 24 eyes. After recovery, all eyes had 20/20 or better visual acuity and normal visual fields as measured with static automated perimetry (SAP). The time between the two postrecovery tests varied from 6 to 56 months. Between test days, the visual fields obtained with SAP remained normal. Ten of the 14 affected eyes showed improvement in median latency on the mfVEP. Six of these eyes fell at or below (improved latency) the 96% confidence interval for the control eyes. None of the 10 initially unaffected eyes fell below the 96% lower limit. Although the improvement was widespread across the field, it did not include all regions. For the six eyes showing clear improvement, on average, 78% of the points had latencies that were shorter on test 2 than on test 1. A substantial percentage of ON/MS patients show a long-term improvement in conduction velocity. Because this improvement can be local, the mfVEP should allow these improvements to be monitored in patients with ON/MS.

  9. Application of 3-Dimensional Printing Technology to Construct an Eye Model for Fundus Viewing Study

    PubMed Central

    Li, Xinhua; Gao, Zhishan; Yuan, Dongqing; Liu, Qinghuai

    2014-01-01

    Objective To construct a life-sized eye model using the three-dimensional (3D) printing technology for fundus viewing study of the viewing system. Methods We devised our schematic model eye based on Navarro's eye and redesigned some parameters because of the change of the corneal material and the implantation of intraocular lenses (IOLs). Optical performance of our schematic model eye was compared with Navarro's schematic eye and other two reported physical model eyes using the ZEMAX optical design software. With computer aided design (CAD) software, we designed the 3D digital model of the main structure of the physical model eye, which was used for three-dimensional (3D) printing. Together with the main printed structure, polymethyl methacrylate(PMMA) aspherical cornea, variable iris, and IOLs were assembled to a physical eye model. Angle scale bars were glued from posterior to periphery of the retina. Then we fabricated other three physical models with different states of ammetropia. Optical parameters of these physical eye models were measured to verify the 3D printing accuracy. Results In on-axis calculations, our schematic model eye possessed similar size of spot diagram compared with Navarro's and Bakaraju's model eye, much smaller than Arianpour's model eye. Moreover, the spherical aberration of our schematic eye was much less than other three model eyes. While in off- axis simulation, it possessed a bit higher coma and similar astigmatism, field curvature and distortion. The MTF curves showed that all the model eyes diminished in resolution with increasing field of view, and the diminished tendency of resolution of our physical eye model was similar to the Navarro's eye. The measured parameters of our eye models with different status of ametropia were in line with the theoretical value. Conclusions The schematic eye model we designed can well simulate the optical performance of the human eye, and the fabricated physical one can be used as a tool in fundus range viewing research. PMID:25393277

  10. Application of 3-dimensional printing technology to construct an eye model for fundus viewing study.

    PubMed

    Xie, Ping; Hu, Zizhong; Zhang, Xiaojun; Li, Xinhua; Gao, Zhishan; Yuan, Dongqing; Liu, Qinghuai

    2014-01-01

    To construct a life-sized eye model using the three-dimensional (3D) printing technology for fundus viewing study of the viewing system. We devised our schematic model eye based on Navarro's eye and redesigned some parameters because of the change of the corneal material and the implantation of intraocular lenses (IOLs). Optical performance of our schematic model eye was compared with Navarro's schematic eye and other two reported physical model eyes using the ZEMAX optical design software. With computer aided design (CAD) software, we designed the 3D digital model of the main structure of the physical model eye, which was used for three-dimensional (3D) printing. Together with the main printed structure, polymethyl methacrylate(PMMA) aspherical cornea, variable iris, and IOLs were assembled to a physical eye model. Angle scale bars were glued from posterior to periphery of the retina. Then we fabricated other three physical models with different states of ammetropia. Optical parameters of these physical eye models were measured to verify the 3D printing accuracy. In on-axis calculations, our schematic model eye possessed similar size of spot diagram compared with Navarro's and Bakaraju's model eye, much smaller than Arianpour's model eye. Moreover, the spherical aberration of our schematic eye was much less than other three model eyes. While in off- axis simulation, it possessed a bit higher coma and similar astigmatism, field curvature and distortion. The MTF curves showed that all the model eyes diminished in resolution with increasing field of view, and the diminished tendency of resolution of our physical eye model was similar to the Navarro's eye. The measured parameters of our eye models with different status of ametropia were in line with the theoretical value. The schematic eye model we designed can well simulate the optical performance of the human eye, and the fabricated physical one can be used as a tool in fundus range viewing research.

  11. 75 FR 72863 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-26

    ..., has had complete loss of vision in his right eye due to a traumatic injury in 1964. The best corrected..., ``While Eugene has suffered traumatic blindness of his right eye his visual field examination and function... injury to his right eye since 1984. The best corrected visual acuity in his right eye is 20/60 and in his...

  12. EDITORIAL: Special issue containing contributions from the Sixth Biennial Research Congress of The Eye and the Chip Special issue containing contributions from the Sixth Biennial Research Congress of The Eye and the Chip

    NASA Astrophysics Data System (ADS)

    Hessburg, Philip C.

    2011-06-01

    Once again Journal of Neural Engineering is devoting an issue to the field of visual neuro-prosthetics. These papers were presented at the Sixth Biennial Research Congress of The Eye and the ChipA 13 DVD set of all presentations at The Eye and the Chip 2010 is available from Carolyn Barth PhD, Detroit Institute of Ophthalmology, 15415 E Jefferson, Grosse Pointe Park MI 48230, USA, 313.824.4710, clbarth@dioeyes.org, held in Detroit in September 2010. In the last decade this field has metamorphosed from 'in all probability a foolish and impractical dream' to a device approved for implantation in Europe and pending approval in the United States, and from a handful of serious efforts to several dozen on every continent save for Antartica. A recent comprehensive volume, Visual Prosthetics [1], edited by Gislin Dagnelie of Johns Hopkins University School of Medicine, focuses closely on this subject and is a tremendous addition to the literature. In his preface Dr Dagnelie notes as follows. 'In the year 2000, the Detroit Institute of Ophthalmology had the inspiration to foster a new collaboration among visual prosthesis researchers, clinicians, and workers in low vision rehabilitation by creating and sponsoring a series of biennial meetings called 'The Eye and the Chip'. Successful beyond expectations, these meetings have become the premier gathering place for researchers from all parts of the world and from very different backgrounds. Invited speakers are scientists who are advancing the field, yet the scale and atmosphere allow all researchers, patients, and the media to come and be updated about progress over the past two years. More perhaps than at other scientific meetings, where investigators tend to gather within disciplines, participants at The Eye and the Chip are challenged to be open-minded, learn about and critique each other's work, and return home with fresh ideas for interdisciplinary approaches. The interdisciplinary character of this book reflects that same spirit.' A letter to us from our co-organizer of The Eye and the Chip, Joseph Rizzo MD, Harvard Medical School, furthers the point that the Research Congress Model is productive. This model is based on a belief that collegiality enhances collaboration and that collaboration accelerates progress. 'At the time of our first The Eye and the Chip meeting, now many years ago, the field of visual prosthetics was still in its infancy. The research community generally held a very skeptical attitude about the possible use of a bio-electronic implant to restore vision, despite the great success of cochlear implants. Over the last two decades our field has matured dramatically, and now there is widespread optimism about the potential for visual implants to help patients who are blind. 'The marked improvement in our status as a field is the result of excellent research from a large critical mass of scientists from throughout the world. It is the general opinion of researchers in our field that The Eye and the Chip meeting has provided the most vibrant source of scientific exchange for our field. The reasons for the success of this meeting relate to the fact that the meeting is devoted to a single topic, it is all-inclusive (anyone who is performing credible research in the field is invited to participate) and it provides a very substantial amount of time for open group discussions. These attributes expand the length of the meeting, which I understand increases the cost of the meeting, but the benefits have been remarkable for our field. Simply stated, The Eye and the Chip meeting provides the best venue for scientific and academic exchange in the world for the field of visual prosthetics.' And, furthermore, following a rather spirited discussion on the end points to be used in evaluating these devices on the third and final day of The Eye and the Chip last September, the Food and Drug Administration (FDA), under the leadership of the US National Eye Institute (NEI), held a fine one-day Congress, 'End Points' in Washington in early May. We, as leaders of The Eye and the Chip, are hopeful that the FDA will continue its meeting in the off-years between The Eye and the Chip research congresses. The field is now so important that an annual meeting exclusively devoted to the subject, especially if Journal of Neural Engineering continues to cover this important work, will not be excessive. References [1] Dagnelie G (ed) 2011 Visual Prosthetics (New York: Springer)

  13. Big-Eyed Bugs Have Big Appetite for Pests

    USDA-ARS?s Scientific Manuscript database

    Many kinds of arthropod natural enemies (predators and parasitoids) inhabit crop fields in Arizona and can have a large negative impact on several pest insect species that also infest these crops. Geocoris spp., commonly known as big-eyed bugs, are among the most abundant insect predators in field c...

  14. Optical projectors simulate human eyes to establish operator's field of view

    NASA Technical Reports Server (NTRS)

    Beam, R. A.

    1966-01-01

    Device projects visual pattern limits of the field of view of an operator as his eyes are directed at a given point on a control panel. The device, which consists of two projectors, provides instant evaluation of visual ability at a point on a panel.

  15. Nanosecond pulsed electric field suppresses development of eyes and germ cells through blocking synthesis of retinoic acid in Medaka (Oryzias latipes).

    PubMed

    Shiraishi, Eri; Hosseini, Hamid; Kang, Dong K; Kitano, Takeshi; Akiyama, Hidenori

    2013-01-01

    Application of nanosecond pulsed electric fields (nsPEFs) has attracted rising attention in various scientific fields including medical, pharmacological, and biological sciences, although its effects and molecular mechanisms leading to the effects remain poorly understood. Here, we show that a single, high-intensity (10-30 kV/cm), 60-ns PEF exposure affects gene expression and impairs development of eyes and germ cells in medaka (Oryzias latipes). Exposure of early blastula stage embryos to nsPEF down-regulated the expression of several transcription factors which are essential for eye development, causing abnormal eye formation. Moreover, the majority of the exposed genetic female embryos showed a fewer number of germ cells similar to that of the control (unexposed) genetic male at 9 days post-fertilization (dpf). However, all-trans retinoic acid (atRA) treatment following the exposure rescued proliferation of germ cells and resumption of normal eye development, suggesting that the phenotypes induced by nsPEF are caused by a decrease of retinoic acid levels. These results confirm that nsPEFs induce novel effects during embryogenesis in medaka.

  16. Diagnostic Ability of Automated Pupillography in Glaucoma.

    PubMed

    Rao, Harsha L; Kadambi, Sujatha V; Mehta, Pooja; Dasari, Srilakshmi; Puttaiah, Narendra K; Pradhan, Zia S; Rao, Dhanraj A S; Shetty, Rohit

    2017-05-01

    To evaluate the diagnostic ability of automated pupillography measurements in glaucoma and study the effect of inter-eye asymmetry in glaucomatous damage on the diagnostic ability. In an observational, cross-sectional study, 47 glaucoma patients and 42 control subjects underwent automated pupillography using a commercially available device. Diagnostic abilities of the pupillary response measurements were evaluated using area under receiver operating characteristic (ROC) curves (AUC) and sensitivities at fixed specificities. Influence of inter-eye asymmetry in glaucoma [inter-eye mean deviation (MD) difference on visual fields (VF)] on the diagnostic ability of pupillography parameters was evaluated by ROC regression approach. The AUCs of automated pupillography parameters ranged from 0.60 (amplitude score with peripheral blue stimulus) to 0.82 (amplitude score with full field white stimulus, Amp-FF-W). Sensitivity at 95% specificity ranged between 5% (amplitude score with full field blue stimulus) and 45% (amplitude score with full field green stimulus). Inter-eye MD difference significantly affected the diagnostic performance of automated pupillography parameters (p < 0.05). AUCs of Amp-FF-W at inter-eye MD difference of 0 dB, 5 dB, 10 dB and 15 dB were 0.71, 0.80, 0.87 and 0.93, respectively, according to the regression model. The corresponding sensitivities at 95% specificity were 20%, 34%, 50% and 66%, respectively. The diagnostic abilities of even the best automated pupillography parameters were only moderate in glaucoma. The performance of these pupillography measurements in detecting glaucoma significantly increased with greater inter-eye asymmetry in the glaucomatous damage.

  17. Secondary neutron dose measurement for proton eye treatment using an eye snout with a borated neutron absorber

    PubMed Central

    2013-01-01

    Background We measured and assessed ways to reduce the secondary neutron dose from a system for proton eye treatment. Methods Proton beams of 60.30 MeV were delivered through an eye-treatment snout in passive scattering mode. Allyl diglycol carbonate (CR-39) etch detectors were used to measure the neutron dose in the external field at 0.00, 1.64, and 6.00 cm depths in a water phantom. Secondary neutron doses were measured and compared between those with and without a high-hydrogen–boron-containing block. In addition, the neutron energy and vertices distribution were obtained by using a Geant4 Monte Carlo simulation. Results The ratio of the maximum neutron dose equivalent to the proton absorbed dose (H(10)/D) at 2.00 cm from the beam field edge was 8.79 ± 1.28 mSv/Gy. The ratio of the neutron dose equivalent to the proton absorbed dose with and without a high hydrogen-boron containing block was 0.63 ± 0.06 to 1.15 ± 0.13 mSv/Gy at 2.00 cm from the edge of the field at depths of 0.00, 1.64, and 6.00 cm. Conclusions We found that the out-of-field secondary neutron dose in proton eye treatment with an eye snout is relatively small, and it can be further reduced by installing a borated neutron absorbing material. PMID:23866307

  18. Eye-tracking novice and expert geologist groups in the field and laboratory

    NASA Astrophysics Data System (ADS)

    Cottrell, R. D.; Evans, K. M.; Jacobs, R. A.; May, B. B.; Pelz, J. B.; Rosen, M. R.; Tarduno, J. A.; Voronov, J.

    2010-12-01

    We are using an Active Vision approach to learn how novices and expert geologists acquire visual information in the field. The Active Vision approach emphasizes that visual perception is an active process wherein new information is acquired about a particular environment through exploratory eye movements. Eye movements are not only influenced by physical stimuli, but are also strongly influenced by high-level perceptual and cognitive processes. Eye-tracking data were collected on ten novices (undergraduate geology students) and 3 experts during a 10-day field trip across California focused on neotectonics. In addition, high-resolution panoramic images were captured at each key locality for use in a semi-immersive laboratory environment. Examples of each data type will be presented. The number of observers will be increased in subsequent field trips, but expert/novice differences are already apparent in the first set of individual eye-tracking records, including gaze time, gaze pattern and object recognition. We will review efforts to quantify these patterns, and development of semi-immersive environments to display geologic scenes. The research is a collaborative effort between Earth scientists, Cognitive scientists and Imaging scientists at the University of Rochester and the Rochester Institute of Technology and with funding from the National Science Foundation.

  19. Rapid mapping of compound eye visual sampling parameters with FACETS, a highly automated wide-field goniometer.

    PubMed

    Douglass, John K; Wehling, Martin F

    2016-12-01

    A highly automated goniometer instrument (called FACETS) has been developed to facilitate rapid mapping of compound eye parameters for investigating regional visual field specializations. The instrument demonstrates the feasibility of analyzing the complete field of view of an insect eye in a fraction of the time required if using non-motorized, non-computerized methods. Faster eye mapping makes it practical for the first time to employ sample sizes appropriate for testing hypotheses about the visual significance of interspecific differences in regional specializations. Example maps of facet sizes are presented from four dipteran insects representing the Asilidae, Calliphoridae, and Stratiomyidae. These maps provide the first quantitative documentation of the frontal enlarged-facet zones (EFZs) that typify asilid eyes, which, together with the EFZs in male Calliphoridae, are likely to be correlated with high-spatial-resolution acute zones. The presence of EFZs contrasts sharply with the almost homogeneous distribution of facet sizes in the stratiomyid. Moreover, the shapes of EFZs differ among species, suggesting functional specializations that may reflect differences in visual ecology. Surveys of this nature can help identify species that should be targeted for additional studies, which will elucidate fundamental principles and constraints that govern visual field specializations and their evolution.

  20. Fluoride geochemistry of thermal waters in Yellowstone National Park: I. Aqueous fluoride speciation

    USGS Publications Warehouse

    Deng, Y.; Nordstrom, D. Kirk; McCleskey, R. Blaine

    2011-01-01

    Thermal water samples from Yellowstone National Park (YNP) have a wide range of pH (1–10), temperature, and high concentrations of fluoride (up to 50 mg/l). High fluoride concentrations are found in waters with field pH higher than 6 (except those in Crater Hills) and temperatures higher than 50 °C based on data from more than 750 water samples covering most thermal areas in YNP from 1975 to 2008. In this study, more than 140 water samples from YNP collected in 2006–2009 were analyzed for free-fluoride activity by ion-selective electrode (ISE) method as an independent check on the reliability of fluoride speciation calculations. The free to total fluoride concentration ratio ranged from <1% at low pH values to >99% at high pH. The wide range in fluoride activity can be explained by strong complexing with H+ and Al3+ under acidic conditions and lack of complexing under basic conditions. Differences between the free-fluoride activities calculated with the WATEQ4F code and those measured by ISE were within 0.3–30% for more than 90% of samples at or above 10−6 molar, providing corroboration for chemical speciation models for a wide range of pH and chemistry of YNP thermal waters. Calculated speciation results show that free fluoride, F−, and major complexes (HF(aq)0">HF(aq)0, AlF2+, AlF2+">AlF2+and AlF30">AlF30) account for more than 95% of total fluoride. Occasionally, some complex species like AlF4-">AlF4-, FeF2+, FeF2+">FeF2+, MgF+ and BF2(OH)2-">BF2(OH)2- may comprise 1–10% when the concentrations of the appropriate components are high. According to the simulation results by PHREEQC and calculated results, the ratio of main fluoride species to total fluoride varies as a function of pH and the concentrations and ratios of F and Al.

  1. Visual function affects prosocial behaviors in older adults.

    PubMed

    Teoli, Dac A; Smith, Merideth D; Leys, Monique J; Jain, Priyanka; Odom, J Vernon

    2016-02-01

    Eye-related pathological conditions such as glaucoma, diabetic retinopathy, and age-related macular degeneration commonly lead to decreased peripheral/central field, decreased visual acuity, and increased functional disability. We sought to answer if relationships exist between measures of visual function and reported prosocial behaviors in an older adult population with eye-related diagnoses. The sample consisted of adults, aged ≥ 60 years old, at an academic hospital's eye institute. Vision ranged from normal to severe impairment. Medical charts determined the visual acuities, ocular disease, duration of disease (DD), and visual fields (VF). Measures of giving help were via validated questionnaires on giving formal support (GFS) and giving informal support; measures of help received were perceived support (PS) and informal support received (ISR). ISR had subscales: tangible support (ISR-T), emotional support (ISR-E), and composite (ISR-C). Visual acuities of the better and worse seeing eyes were converted to LogMAR values. VF information converted to a 4-point rating scale of binocular field loss severity. DD was in years. Among 96 participants (mean age 73.28; range 60-94), stepwise regression indicated a relationship of visual variables to GFS (p < 0.05; Multiple R (2) = 0.1679 with acuity-better eye, VF rating, and DD), PS (p < 0.05; Multiple R (2) = 0.2254 with acuity-better eye), ISR-C (p < 0.05; Multiple R (2) = 0.041 with acuity-better eye), and ISR-T (p < 0.05; Multiple R (2) = 0.1421 with acuity-better eye). The findings suggest eye-related conditions can impact levels and perceptions of support exchanges. Our data reinforces the importance of visual function as an influence on prosocial behavior in older adults.

  2. Binocular Neurons in Parastriate Cortex: Interocular ‘Matching’ of Receptive Field Properties, Eye Dominance and Strength of Silent Suppression

    PubMed Central

    Wang, Chun; Dreher, Bogdan

    2014-01-01

    Spike-responses of single binocular neurons were recorded from a distinct part of primary visual cortex, the parastriate cortex (cytoarchitectonic area 18) of anaesthetized and immobilized domestic cats. Functional identification of neurons was based on the ratios of phase-variant (F1) component to the mean firing rate (F0) of their spike-responses to optimized (orientation, direction, spatial and temporal frequencies and size) sine-wave-luminance-modulated drifting grating patches presented separately via each eye. In over 95% of neurons, the interocular differences in the phase-sensitivities (differences in F1/F0 spike-response ratios) were small (≤0.3) and in over 80% of neurons, the interocular differences in preferred orientations were ≤10°. The interocular correlations of the direction selectivity indices and optimal spatial frequencies, like those of the phase sensitivies and optimal orientations, were also strong (coefficients of correlation r ≥0.7005). By contrast, the interocular correlations of the optimal temporal frequencies, the diameters of summation areas of the excitatory responses and suppression indices were weak (coefficients of correlation r ≤0.4585). In cells with high eye dominance indices (HEDI cells), the mean magnitudes of suppressions evoked by stimulation of silent, extra-classical receptive fields via the non-dominant eyes, were significantly greater than those when the stimuli were presented via the dominant eyes. We argue that the well documented ‘eye-origin specific’ segregation of the lateral geniculate inputs underpinning distinct eye dominance columns in primary visual cortices of mammals with frontally positioned eyes (distinct eye dominance columns), combined with significant interocular differences in the strength of silent suppressive fields, putatively contribute to binocular stereoscopic vision. PMID:24927276

  3. Detection of longitudinal visual field progression in glaucoma using machine learning.

    PubMed

    Yousefi, Siamak; Kiwaki, Taichi; Zheng, Yuhui; Suigara, Hiroki; Asaoka, Ryo; Murata, Hiroshi; Lemij, Hans; Yamanishi, Kenji

    2018-06-16

    Global indices of standard automated perimerty are insensitive to localized losses, while point-wise indices are sensitive but highly variable. Region-wise indices sit in between. This study introduces a machine-learning-based index for glaucoma progression detection that outperforms global, region-wise, and point-wise indices. Development and comparison of a prognostic index. Visual fields from 2085 eyes of 1214 subjects were used to identify glaucoma progression patterns using machine learning. Visual fields from 133 eyes of 71 glaucoma patients were collected 10 times over 10 weeks to provide a no-change, test-retest dataset. The parameters of all methods were identified using visual field sequences in the test-retest dataset to meet fixed 95% specificity. An independent dataset of 270 eyes of 136 glaucoma patients and survival analysis were utilized to compare methods. The time to detect progression in 25% of the eyes in the longitudinal dataset using global mean deviation (MD) was 5.2 years (95% confidence interval, 4.1 - 6.5 years); 4.5 years (4.0 - 5.5) using region-wise, 3.9 years (3.5 - 4.6) using point-wise, and 3.5 years (3.1 - 4.0) using machine learning analysis. The time until 25% of eyes showed subsequently confirmed progression after two additional visits were included were 6.6 years (5.6 - 7.4 years), 5.7 years (4.8 - 6.7), 5.6 years (4.7 - 6.5), and 5.1 years (4.5 - 6.0) for global, region-wise, point-wise, and machine learning analyses, respectively. Machine learning analysis detects progressing eyes earlier than other methods consistently, with or without confirmation visits. In particular, machine learning detects more slowly progressing eyes than other methods. Copyright © 2018 Elsevier Inc. All rights reserved.

  4. Secrets in the eyes of Black Oystercatchers: A new sexing technique

    USGS Publications Warehouse

    Guzzetti, B.M.; Talbot, S.L.; Tessler, D.F.; Gill, V.A.; Murphy, E.C.

    2008-01-01

    Sexing oystercatchers in the field is difficult because males and females have identical plumage and are similar in size. Although Black Oystercatchers (Haematopus bachmani) are sexually dimorphic, using morphology to determine sex requires either capturing both pair members for comparison or using discriminant analyses to assign sex probabilistically based on morphometric traits. All adult Black Oystercatchers have bright yellow eyes, but some of them have dark specks, or eye flecks, in their irides. We hypothesized that this easily observable trait was sex-linked and could be used as a novel diagnostic tool for identifying sex. To test this, we compared data for oystercatchers from genetic molecular markers (CHD-W/CHD-Z and HINT-W/HINT-Z), morphometric analyses, and eye-fleck category (full eye flecks, slight eye flecks, and no eye flecks). Compared to molecular markers, we found that discriminant analyses based on morphological characteristics yielded variable results that were confounded by geographical differences in morphology. However, we found that eye flecks were sex-linked. Using an eye-fleck model where all females have full eye flecks and males have either slight eye flecks or no eye flecks, we correctly assigned the sex of 117 of 125 (94%) oystercatchers. Using discriminant analysis based on morphological characteristics, we correctly assigned the sex of 105 of 119 (88%) birds. Using the eye-fleck technique for sexing Black Oystercatchers may be preferable for some investigators because it is as accurate as discriminant analysis based on morphology and does not require capturing the birds. ??2008 Association of Field Ornithologists.

  5. Analysis and implementation of the foveated vision of the raptor eye

    NASA Astrophysics Data System (ADS)

    Long, Aaron D.; Narayanan, Ram M.; Kane, Timothy J.; Rice, Terence F.; Tauber, Michael J.

    2016-05-01

    A foveated optical system has non-uniform resolution across its field of view. Typically, the resolution of such a lens is peaked in the center region of field of view, such as in the human eye. In biological systems this is often a result of localized depressions on the retina called foveae. Birds of prey, or raptors, have two foveae in each eye, each of which accounts for a localized region of high magnification within the raptor's field of view. This paper presents an analysis of the bifoveated vision of raptors and presents a method whereby this unique optical characteristic may be achieved in an optical system using freeform optics and aberration correction techniques.

  6. Structural-metabolic organization of field 4 of the cat brain in normal conditions and after unilateral enucleation of the eye.

    PubMed

    Zykin, P A

    2005-01-01

    Comparative data on the structural-metabolic organization of field 4 of the cat brain in normal conditions and after unilateral enucleation of the eye are presented. Cytochrome oxidase was detected histochemically. Data were processed by a computerized method using an original video capture system. Data were obtained demonstrating the uneven distribution of enzyme along sublayer IlIb of field 4 in animals with unilateral enucleation. A hypothesis based on published data is suggested whereby the alternation of high- and low-reactive areas is evidence for the ordering of the retinal representations of the right and left eyes in the sensorimotor cortex.

  7. Neural correlates of the eye dominance effect in human face perception: the left-visual-field superiority for faces revisited.

    PubMed

    Jung, Wookyoung; Kang, Joong-Gu; Jeon, Hyeonjin; Shim, Miseon; Sun Kim, Ji; Leem, Hyun-Sung; Lee, Seung-Hwan

    2017-08-01

    Faces are processed best when they are presented in the left visual field (LVF), a phenomenon known as LVF superiority. Although one eye contributes more when perceiving faces, it is unclear how the dominant eye (DE), the eye we unconsciously use when performing a monocular task, affects face processing. Here, we examined the influence of the DE on the LVF superiority for faces using event-related potentials. Twenty left-eye-dominant (LDE group) and 23 right-eye-dominant (RDE group) participants performed the experiments. Face stimuli were randomly presented in the LVF or right visual field (RVF). The RDE group exhibited significantly larger N170 amplitudes compared with the LDE group. Faces presented in the LVF elicited N170 amplitudes that were significantly more negative in the RDE group than they were in the LDE group, whereas the amplitudes elicited by stimuli presented in the RVF were equivalent between the groups. The LVF superiority was maintained in the RDE group but not in the LDE group. Our results provide the first neural evidence of the DE's effects on the LVF superiority for faces. We propose that the RDE may be more biologically specialized for face processing. © The Author (2017). Published by Oxford University Press.

  8. Neural correlates of the eye dominance effect in human face perception: the left-visual-field superiority for faces revisited

    PubMed Central

    Jung, Wookyoung; Kang, Joong-Gu; Jeon, Hyeonjin; Shim, Miseon; Sun Kim, Ji; Leem, Hyun-Sung

    2017-01-01

    Abstract Faces are processed best when they are presented in the left visual field (LVF), a phenomenon known as LVF superiority. Although one eye contributes more when perceiving faces, it is unclear how the dominant eye (DE), the eye we unconsciously use when performing a monocular task, affects face processing. Here, we examined the influence of the DE on the LVF superiority for faces using event-related potentials. Twenty left-eye-dominant (LDE group) and 23 right-eye-dominant (RDE group) participants performed the experiments. Face stimuli were randomly presented in the LVF or right visual field (RVF). The RDE group exhibited significantly larger N170 amplitudes compared with the LDE group. Faces presented in the LVF elicited N170 amplitudes that were significantly more negative in the RDE group than they were in the LDE group, whereas the amplitudes elicited by stimuli presented in the RVF were equivalent between the groups. The LVF superiority was maintained in the RDE group but not in the LDE group. Our results provide the first neural evidence of the DE’s effects on the LVF superiority for faces. We propose that the RDE may be more biologically specialized for face processing. PMID:28379584

  9. Eye gazing direction inspection based on image processing technique

    NASA Astrophysics Data System (ADS)

    Hao, Qun; Song, Yong

    2005-02-01

    According to the research result in neural biology, human eyes can obtain high resolution only at the center of view of field. In the research of Virtual Reality helmet, we design to detect the gazing direction of human eyes in real time and feed it back to the control system to improve the resolution of the graph at the center of field of view. In the case of current display instruments, this method can both give attention to the view field of virtual scene and resolution, and improve the immersion of virtual system greatly. Therefore, detecting the gazing direction of human eyes rapidly and exactly is the basis of realizing the design scheme of this novel VR helmet. In this paper, the conventional method of gazing direction detection that based on Purklinje spot is introduced firstly. In order to overcome the disadvantage of the method based on Purklinje spot, this paper proposed a method based on image processing to realize the detection and determination of the gazing direction. The locations of pupils and shapes of eye sockets change with the gazing directions. With the aid of these changes, analyzing the images of eyes captured by the cameras, gazing direction of human eyes can be determined finally. In this paper, experiments have been done to validate the efficiency of this method by analyzing the images. The algorithm can carry out the detection of gazing direction base on normal eye image directly, and it eliminates the need of special hardware. Experiment results show that the method is easy to implement and have high precision.

  10. Properties of the statpac visual field index.

    PubMed

    Artes, Paul H; O'Leary, Neil; Hutchison, Donna M; Heckler, Lisa; Sharpe, Glen P; Nicolela, Marcelo T; Chauhan, Balwantray C

    2011-06-08

    Purpose. To compare the properties of the visual field index (VFI) to those of mean deviation (MD) in patients with glaucoma. Methods. MD and VFI were calculated in data obtained from an ongoing longitudinal study in which patients with glaucoma (N = 109, 204 eyes) were observed for 9.8 years (median, 21 tests) with static automated perimetry. MD and VFI were compared in one test of each eye, and a subset of 30 tests were selected to compare the VFI with the judgments of eight experts who judged the percentage of the remaining visual field. In series of tests obtained over time, rates of change, statistical significance, evidence of nonlinearity, and variability were compared between both indices. Results. In single tests, MD and VFI were closely related (r = 0.88, P < 0.001). The relationship between both indices appeared linear, except in visual fields with MDs better than -5.0 dB where 29 (22%) of 129 eyes exhibited a ceiling effect (VFI = 100%). Based on this relationship, the predicted VFIs for visual fields with MDs of -5, -10, and -15 dB were 91%, 76%, and 60%, respectively. The percentage of remaining visual field suggested by the VFI exceeded the range of the experts' subjective judgments in 16 (53%) of 30 eyes. In series of tests obtained over time, rates of change with the two indices were closely related (r = 0.79, P < 0.001), and statistically significant reductions over time (P < 0.05) occurred in a similar number of eyes (92 [45%] with MD, and 87 [43%] with VFI). Of the 105 eyes with statistically significant (P < 0.05) negative trend in either MD or VFI, 74 (70%) showed such trends with both indices (κ = 0.69). The variability of MD and VFI increased with damage, and there was no evidence that change over time was more linear with VFI than with MD. Conclusions. The VFI provides a simple and understandable metric of visual field damage, but its estimates of remaining visual field were more optimistic than those of the experts. Rates of change over time with both indices were closely related, but the reliance of the VFI on pattern deviation probability maps caused a ceiling effect that may have reduced its sensitivity to change in eyes with early damage. In this group of patients there was no evidence to suggest that the VFI is either superior or inferior to the MD as a summary measure of visual field damage.

  11. F/EF-111 Basing at Cannon Air Force Base, Curry County, New Mexico

    DTIC Science & Technology

    1992-04-01

    construction on Base and at Melrose Rang6, Mount Dora Military Operations Area (MOA), and Pecos MOA are proposed actions associated with the realignment...Under the Mount Dora MOA, 1987 ....................................................................... 3-13 Table 3.1-5 Visitation at State and...National Parks Located in the Area Under the Mount Dora MOA ........................... 3-14 Table 3.2-1 Federal and State Ambient Air Quality Standards

  12. Silvicultural Prescriptions Influence the Proportion of High-Quality Hardwood Butt Logs Harvested over a Half-Century of Management

    Treesearch

    John P. Brown; Melissa A. Thomas-Van Gundy; Thomas M. Schuler; Janice K. Wiedenbeck

    2018-01-01

    A long-term study on the Fernow Experimental Forest (FEF) in West Virginia provided an opportunity to test for differences in the timber quality of trees harvested from three silvicultural practices (HarvestType): diameter-limit, patch cutting, and single-tree selection. The effects of HarvestType and site index (SI) over time on the harvested proportion of trees with...

  13. Monitoring the eye lens: which dose quantity is adequate?

    NASA Astrophysics Data System (ADS)

    Behrens, R.; Dietze, G.

    2010-07-01

    Recent epidemiological studies suggest a rather low dose threshold (below 0.5 Gy) for the induction of a cataract of the eye lens. Some other studies even assume that there is no threshold at all. Therefore, protection measures have to be optimized and current dose limits for the eye lens may be reduced in the future. The question of which personal dose equivalent quantity is appropriate for monitoring the dose to the eye lens arises from this situation. While in many countries dosemeters calibrated in terms of the dose equivalent quantity Hp(0.07) have been seen as being adequate for monitoring the dose to the eye lens, this might be questionable in the case of reduced dose limits and, thus, it may become necessary to use the dose equivalent quantity Hp(3) for this purpose. To discuss this question, the dose conversion coefficients for the equivalent dose of the eye lens (in the following eye lens dose) were determined for realistic photon and beta radiation fields and compared with the values of the corresponding conversion coefficients for the different operational quantities. The values obtained lead to the following conclusions: in radiation fields where most of the dose comes from photons, especially x-rays, it is appropriate to use dosemeters calibrated in terms of Hp(0.07) on a slab phantom, while in other radiation fields (dominated by beta radiation or unknown contributions of photon and beta radiation) dosemeters calibrated in terms of Hp(3) on a slab phantom should be used. As an alternative, dosemeters calibrated in terms of Hp(0.07) on a slab phantom could also be used; however, in radiation fields containing beta radiation with the end point energy near 1 MeV, an overestimation of the eye lens dose by up to a factor of 550 is possible.

  14. Monitoring the eye lens: which dose quantity is adequate?

    PubMed

    Behrens, R; Dietze, G

    2010-07-21

    Recent epidemiological studies suggest a rather low dose threshold (below 0.5 Gy) for the induction of a cataract of the eye lens. Some other studies even assume that there is no threshold at all. Therefore, protection measures have to be optimized and current dose limits for the eye lens may be reduced in the future. The question of which personal dose equivalent quantity is appropriate for monitoring the dose to the eye lens arises from this situation. While in many countries dosemeters calibrated in terms of the dose equivalent quantity H(p)(0.07) have been seen as being adequate for monitoring the dose to the eye lens, this might be questionable in the case of reduced dose limits and, thus, it may become necessary to use the dose equivalent quantity H(p)(3) for this purpose. To discuss this question, the dose conversion coefficients for the equivalent dose of the eye lens (in the following eye lens dose) were determined for realistic photon and beta radiation fields and compared with the values of the corresponding conversion coefficients for the different operational quantities. The values obtained lead to the following conclusions: in radiation fields where most of the dose comes from photons, especially x-rays, it is appropriate to use dosemeters calibrated in terms of H(p)(0.07) on a slab phantom, while in other radiation fields (dominated by beta radiation or unknown contributions of photon and beta radiation) dosemeters calibrated in terms of H(p)(3) on a slab phantom should be used. As an alternative, dosemeters calibrated in terms of H(p)(0.07) on a slab phantom could also be used; however, in radiation fields containing beta radiation with the end point energy near 1 MeV, an overestimation of the eye lens dose by up to a factor of 550 is possible.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goren, A.I.; Hellman, S.; Brenner, S.

    During spring 1984, 2,334 second and 2,000 fifth-grade schoolchildren living in three Haifa Bay areas on the eastern Mediterranean coast with different levels of air pollution were studied. The parents of these children filled out American Thoracic Society and National Heart and Lung Institute health questionnaires, and the children performed the following pulmonary function tests (PFT): FVC, FEV{sub 1}, FEV{sub 1}/FEV, PEF, FEF{sub 50}, and FEF{sub 75}. A trend of higher prevalence of most reported respiratory symptoms was found for schoolchildren growing up in the medium and high pollution areas as compared with the low pollution area. Part of themore » reported respiratory diseases were significantly more common among children from the high pollution area. Models fitted for the respiratory conditions that differed significantly among the three areas of residence also included background variables that could be responsible for these differences. Relative risk values, which were calculated from the logistic models, were in the range of 1.38 for sputum with cold and 1.81 for sputum without cold for children from the high pollution area as compared with 1.00 for children from the low pollution area. All the measured values of PFT were within the normal range. There was no consistent trend of reduced pulmonary function that characterized any residential area.« less

  16. Forskolin compared with beclomethasone for prevention of asthma attacks: a single-blind clinical trial.

    PubMed

    Huerta, M; Urzúa, Z; Trujillo, X; González-Sánchez, R; Trujillo-Hernández, B

    2010-01-01

    This single-blind study compared the efficacy of oral forskolin versus inhaled beclomethasone for mild or moderately persistent adult asthma. Patients were randomly assigned to receive forskolin (one 10-mg capsule orally per day; n = 30) or beclomethasone (two 50 microg inhalations every 12 h; n = 30) for 2 months. No statistically significant improvement occurred in any lung function parameter in the forskolin-treated patients. Subjects in the beclomethasone-treated group presented a slight but statistically significant improvement in percentage forced expiratory volume in 1 s (FEV(1)), percentage forced expiratory flow in the middle (25 - 75%) expiratory phase (FEF(25 - 75%)) and percentage forced vital capacity (FVC) after 2 months of treatment, though the improvement in absolute values for FEV(1), FEF(25 - 75%), FVC and FEV(1):FVC did not reach statistical significance. There was no statistically significant difference between the forskolin and beclomethasone treatment groups for any lung function parameter at baseline or after treatment. None of the beclomethasone-treated patients had an asthma attack and one forskolin-treated patient had a mild asthma attack during the 2-month study period. More studies are needed in adult asthma patients to confirm whether forskolin may be a useful preventive treatment for mild or moderately persistent adult asthma.

  17. Association between the Type of Workplace and Lung Function in Copper Miners

    PubMed Central

    Gruszczyński, Leszek; Wojakowska, Anna; Ścieszka, Marek; Turczyn, Barbara; Schmidt, Edward

    2016-01-01

    The aim of the analysis was to retrospectively assess changes in lung function in copper miners depending on the type of workplace. In the groups of 225 operators, 188 welders, and 475 representatives of other jobs, spirometry was performed at the start of employment and subsequently after 10, 20, and 25 years of work. Spirometry Longitudinal Data Analysis software was used to estimate changes in group means for FEV1 and FVC. Multiple linear regression analysis was used to assess an association between workplace and lung function. Lung function assessed on the basis of calculation of longitudinal FEV1 (FVC) decline was similar in all studied groups. However, multiple linear regression model used in cross-sectional analysis revealed an association between workplace and lung function. In the group of welders, FEF75 was lower in comparison to operators and other miners as early as after 10 years of work. Simultaneously, in smoking welders, the FEV1/FVC ratio was lower than in nonsmokers (p < 0,05). The interactions between type of workplace and smoking (p < 0,05) in their effect on FVC, FEV1, PEF, and FEF50 were shown. Among underground working copper miners, the group of smoking welders is especially threatened by impairment of lung ventilatory function. PMID:27274987

  18. Antihistamine medication may alleviate negative effects of prenatal exposure to polycyclic aromatic hydrocarbons (PAH) on lung function in children. Birth cohort prospective study.

    PubMed

    Jedrychowski, Wieslaw A; Perera, Frederica P; Maugeri, Umberto; Majewska, Renata; Spengler, Jack; Mroz, Elzbieta; Flak, Elzbieta; Klimaszewska-Rembiasz, Maria; Camman, David

    2015-05-01

    The main purpose of the present study was to test the hypothesis that the depressed lung growth attributable to prenatal exposure to polycyclic aromatic hydrocarbons (PAH) may be modified by the intake of antihistamine medications. Individual prenatal PAH exposure was assessed by personal air monitoring in 176 children who were followed over nine years, in the course of which outdoor residential air monitoring, allergic skin tests for indoor allergens, lung function tests (FVC, FEV(1), FEV(05), and FEF(25-75)) were performed. The analysis with the General Estimated Equation (GEE) showed no association between prenatal PAH exposure and lung function in the group of children who were reported to be antihistamine users. However, in the group of antihistamine non-users all lung function tests except for FEF(25-75) were significantly and inversely associated with prenatal airborne PAH exposure. The results of the study suggest that the intake of antihistamine medications in early childhood may inhibit the negative effect of fetal PAH exposure on lung growth and provides additional indirect evidence for the hypothesis that lung alterations in young children resulting from PAH exposure may be caused by the allergic inflammation within lung. © 2014 Wiley Periodicals, Inc.

  19. Psychophysical assessment of low visual function in patients with retinal degenerative diseases (RDDs) with the Diagnosys full-field stimulus threshold (D-FST).

    PubMed

    Klein, M; Birch, D G

    2009-12-01

    To determine whether the Diagnosys full-field stimulus threshold (D-FST) is a valid, sensitive and repeatable psychophysical method of measuring and following visual function in low-vision subjects. Fifty-three affected eyes of 42 subjects with severe retinal degenerative diseases (RDDs) were tested with achromatic stimuli on the D-FST. Included were subjects who were either unable to perform a static perimetric field or had non-detectable or sub-microvolt electroretinograms (ERGs). A subset of 21 eyes of 17 subjects was tested on both the D-FST and the FST2, a previous established full-field threshold test. Seven eyes of 7 normal control subjects were tested on both the D-FST and the FST2. Results for the two methods were compared with the Bland-Altman test. On the D-FST, a threshold could successfully be determined for 13 of 14 eyes with light perception (LP) only (median 0.9 +/- 1.4 log cd/m2), and all eyes determined to be counting fingers (CF; median 0.3 +/- 1.8 log cd/m2). The median full-field threshold for the normal controls was -4.3 +/- 0.6 log cd/m2 on the D-FST and -4.8 +/- 0.9 log cd/m2 on the FST2. The D-FST offers a commercially available method with a robust psychophysical algorithm and is a useful tool for following visual function in low vision subjects.

  20. Light and dark adaptation of visually perceived eye level controlled by visual pitch.

    PubMed

    Matin, L; Li, W

    1995-01-01

    The pitch of a visual field systematically influences the elevation at which a monocularly viewing subject sets a target so as to appear at visually perceived eye level (VPEL). The deviation of the setting from true eye level average approximately 0.6 times the angle of pitch while viewing a fully illuminated complexly structured visual field and is only slightly less with one or two pitched-from-vertical lines in a dark field (Matin & Li, 1994a). The deviation of VPEL from baseline following 20 min of dark adaptation reaches its full value less than 1 min after the onset of illumination of the pitched visual field and decays exponentially in darkness following 5 min of exposure to visual pitch, either 30 degrees topbackward or 20 degrees topforward. The magnitude of the VPEL deviation measured with the dark-adapted right eye following left-eye exposure to pitch was 85% of the deviation that followed pitch exposure of the right eye itself. Time constants for VPEL decay to the dark baseline were the same for same-eye and cross-adaptation conditions and averaged about 4 min. The time constants for decay during dark adaptation were somewhat smaller, and the change during dark adaptation extended over a 16% smaller range following the viewing of the dim two-line pitched-from-vertical stimulus than following the viewing of the complex field. The temporal course of light and dark adaptation of VPEL is virtually identical to the course of light and dark adaptation of the scotopic luminance threshold following exposure to the same luminance. We suggest that, following rod stimulation along particular retinal orientations by portions of the pitched visual field, the storage of the adaptation process resides in the retinogeniculate system and is manifested in the focal system as a change in luminance threshold and in the ambient system as a change in VPEL. The linear model previously developed to account for VPEL, which was based on the interaction of influences from the pitched visual field and extraretinal influences from the body-referenced mechanism, was employed to incorporate the effects of adaptation. Connections between VPEL adaptation and other cases of perceptual adaptation of visual direction are described.

  1. Ethambutol/Linezolid Toxic Optic Neuropathy.

    PubMed

    Libershteyn, Yevgeniya

    2016-02-01

    To report a rare toxic optic neuropathy after long-term use of two medications: ethambutol and linezolid. A 65-year-old man presented to the Miami Veterans Affairs Medical Center in December 2014 for evaluation of progressive vision decrease in both eyes. The patient presented with best-corrected visual acuities of 20/400 in the right eye and counting fingers at 5 feet in the left eye. Color vision was significantly reduced in both eyes. Visual fields revealed a cecocentral defect in both eyes. His fundus and optic nerve examination was unremarkable. Because vision continued to decline after discontinuation of ethambutol, linezolid was also discontinued, after which vision, color vision, and visual fields improved. Because of these findings, the final diagnosis was toxic optic neuropathy. Final visual outcome was 20/30 in the right eye and 20/40 in the left eye. Drug-associated toxic optic neuropathy is a rare but vision-threatening condition. Diagnosis is made based on an extensive case history and careful clinical examination. The examination findings include varying decrease in vision, normal pupils and extraocular muscles, and unremarkable fundoscopy, with the possibility of swollen optic discs in the acute stage of the optic neuropathy. Other important findings descriptive of toxic optic neuropathy include decreased color vision and cecocentral visual field defects. This case illustrates the importance of knowledge of all medications and/or substances a patient consumes that may cause a toxic reaction and discontinuing them immediately if the visual functions are worsening or not improving.

  2. Development of a low cost high precision three-layer 3D artificial compound eye.

    PubMed

    Zhang, Hao; Li, Lei; McCray, David L; Scheiding, Sebastian; Naples, Neil J; Gebhardt, Andreas; Risse, Stefan; Eberhardt, Ramona; Tünnermann, Andreas; Yi, Allen Y

    2013-09-23

    Artificial compound eyes are typically designed on planar substrates due to the limits of current imaging devices and available manufacturing processes. In this study, a high precision, low cost, three-layer 3D artificial compound eye consisting of a 3D microlens array, a freeform lens array, and a field lens array was constructed to mimic an apposition compound eye on a curved substrate. The freeform microlens array was manufactured on a curved substrate to alter incident light beams and steer their respective images onto a flat image plane. The optical design was performed using ZEMAX. The optical simulation shows that the artificial compound eye can form multiple images with aberrations below 11 μm; adequate for many imaging applications. Both the freeform lens array and the field lens array were manufactured using microinjection molding process to reduce cost. Aluminum mold inserts were diamond machined by the slow tool servo method. The performance of the compound eye was tested using a home-built optical setup. The images captured demonstrate that the proposed structures can successfully steer images from a curved surface onto a planar photoreceptor. Experimental results show that the compound eye in this research has a field of view of 87°. In addition, images formed by multiple channels were found to be evenly distributed on the flat photoreceptor. Additionally, overlapping views of the adjacent channels allow higher resolution images to be re-constructed from multiple 3D images taken simultaneously.

  3. One in the eye for an orthopaedic surgeon.

    PubMed Central

    Lourie, J.; Hamid, K.

    1996-01-01

    Despite many reports of injuries to surgeons during operative procedures, there is no record of an eye injury caused by a foreign body. Orthopaedic surgeons are particularly vulnerable to such injury. An instance in which a penetrating eye injury occurred while hammering a rasp into the femur during a hip replacement is described. There is a potential oblique trajectory for a foreign body to reach the eye from the operative field despite the use of a visor for eye protection. Images Figure 1 Figure 2 PMID:8659981

  4. A Sticky Situation.

    PubMed

    Weng, Christina Y; Khimani, Karima S; Foroozan, Rod; Gospe, Sidney M; Bhatti, M Tariq

    2018-04-26

    An 81-year-old man with bilateral progressively blurry vision and optic disc swelling was referred for evaluation. Examination and ancillary testing confirmed a diagnosis of bilateral vitreopapillary traction (VPT) accompanied by unilateral tractional retinoschisis in the right eye. Pars plana vitrectomy was performed to release the traction in both eyes. Visual acuity improved in the right eye and stabilized in the left eye. Retinoschisis in the right eye resolved. The visual field improved in both eyes, although the left eye demonstrated a persistent hemifield defect likely attributable to a prior optic neuropathy. Distinguishing VPT optic neuropathy (VPTON) from nonarteritic anterior ischemic optic neuropathy (NAION) is discussed. Copyright © 2018 Elsevier Inc. All rights reserved.

  5. Magnetic eye tracking in mice

    PubMed Central

    Payne, Hannah L

    2017-01-01

    Eye movements provide insights about a wide range of brain functions, from sensorimotor integration to cognition; hence, the measurement of eye movements is an important tool in neuroscience research. We describe a method, based on magnetic sensing, for measuring eye movements in head-fixed and freely moving mice. A small magnet was surgically implanted on the eye, and changes in the magnet angle as the eye rotated were detected by a magnetic field sensor. Systematic testing demonstrated high resolution measurements of eye position of <0.1°. Magnetic eye tracking offers several advantages over the well-established eye coil and video-oculography methods. Most notably, it provides the first method for reliable, high-resolution measurement of eye movements in freely moving mice, revealing increased eye movements and altered binocular coordination compared to head-fixed mice. Overall, magnetic eye tracking provides a lightweight, inexpensive, easily implemented, and high-resolution method suitable for a wide range of applications. PMID:28872455

  6. Optical coherence tomography detects characteristic retinal nerve fiber layer thickness corresponding to band atrophy of the optic discs.

    PubMed

    Kanamori, Akiyasu; Nakamura, Makoto; Matsui, Noriko; Nagai, Azusa; Nakanishi, Yoriko; Kusuhara, Sentaro; Yamada, Yuko; Negi, Akira

    2004-12-01

    To analyze retinal nerve fiber layer (RNFL) thickness in eyes with band atrophy by use of optical coherence tomography (OCT) and to evaluate the ability of OCT to detect this characteristic pattern of RNFL loss. Cross-sectional, retrospective study. Thirty-four eyes of 18 patients with bitemporal hemianopia caused by optic chiasm compression by chiasmal tumors were studied. All eyes were divided into 3 groups according to visual field loss grading after Goldmann perimetry. Retinal nerve fiber layer thickness measurements with OCT. Retinal nerve fiber layer thickness around the optic disc was measured by OCT (3.4-mm diameter circle). Calculation of the changes in OCT parameters, including the horizontal (nasal + temporal quadrant RNFL thickness) and vertical values (superior + inferior quadrant RNFL thickness) was based on data from 160 normal eyes. Comparison between the 3 visual field grading groups was done with the analysis of variance test. The receiver operating characteristic (ROC) curve for the horizontal and vertical value were calculated, and the areas under the curve (AUC) were compared. Retinal nerve fiber layer thickness in eyes with band atrophy decreased in all OCT parameters. The reduction rate in average and temporal RNFL thickness and horizontal value was correlated with visual field grading. The AUC of horizontal value was 0.970+/-0.011, which was significantly different from AUC of vertical value (0.903+/-0.022). The degree of RNFL thickness reduction correlated with that of visual field defects. Optical coherence tomography was able to identify the characteristic pattern of RNFL loss in these eyes.

  7. Through Their Eyes: Tracking the Gaze of Students in a Geology Field Course

    ERIC Educational Resources Information Center

    Maltese, Adam V.; Balliet, Russell N.; Riggs, Eric M.

    2013-01-01

    The focus of this research was to investigate how students learn to do fieldwork through observation. This study addressed the following questions: (1) Can mobile eye-tracking devices provide a robust source of data to investigate the observations and workflow of novice students while participating in a field exercise? If so, what are the…

  8. The Eyes Have It

    NASA Technical Reports Server (NTRS)

    1999-01-01

    NASA'S Ames Research Center contracted with SRI international to contract a device that would be able to anticipate, track, and monitor involuntary ocular movement horizontally, vertically, and with respect to depth-of-field. This development helped research institutions to understand the eye. The Eyetracker, manufactured and distributed by Forward Optical Technologies, Inc. is now used in the clinical/medical field.

  9. Investigation of the isoplanatic patch and wavefront aberration along the pupillary axis compared to the line of sight in the eye

    PubMed Central

    Nowakowski, Maciej; Sheehan, Matthew; Neal, Daniel; Goncharov, Alexander V.

    2012-01-01

    Conventional optical systems usually provide best image quality on axis, while showing unavoidable gradual decrease in image quality towards the periphery of the field. The optical system of the human eye is not an exception. Within a limiting boundary the image quality can be considered invariant with field angle, and this region is known as the isoplanatic patch. We investigate the isoplanatic patch of eight healthy eyes and measure the wavefront aberration along the pupillary axis compared to the line of sight. The results are used to discuss methods of ocular aberration correction in wide-field retinal imaging with particular application to multi-conjugate adaptive optics systems. PMID:22312578

  10. Relevance of wide-field autofluorescence imaging in Birdshot retinochoroidopathy: descriptive analysis of 76 eyes.

    PubMed

    Piffer, Anne-Laure Le; Boissonnot, Michèle; Gobert, Frédéric; Zenger, Anita; Wolf, Sebastian; Wolf, Ute; Korobelnik, Jean-François; Rougier, Marie-Bénédicte

    2014-09-01

    To study and classify retinal lesions in patients with birdshot disease using wide-field autofluorescence imaging and correlate them according to patients' visual status. A multicentre study was carried out on 76 eyes of 39 patients with birdshot disease, analysing colour images and under autofluorescence using the wide-field Optomap(®) imaging system. This was combined with a complete clinical exam and analysis of the macula with OCT. In over 80% of the eyes, a chorioretinal lesion has been observed under autofluorescence with a direct correlation between the extent of the lesion and visual status. The presence of macular hypo-autofluorescence was correlated with a decreased visual acuity, due to the presence of a macular oedema, active clinical inflammation or an epiretinal membrane. The hypo-autofluorescence observed correlated with the duration of the disease and the degree of inflammation in the affected eye, indicating a secondary lesion in the pigment epithelium in relation to the choroid. The pigment epithelium was affected in a diffuse manner, as in almost 50% of the eyes the wider peripheral retina was affected. Wide-field autofluorescence imaging could appear to be a useful examination when monitoring patients, to look for areas of macular hypo-autofluorescence responsible for an irreversible loss of vision. © 2013 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  11. Reduction in mean deviation values in automated perimetry in eyes with multifocal compared to monofocal intraocular lens implants.

    PubMed

    Farid, Marjan; Chak, Garrick; Garg, Sumit; Steinert, Roger F

    2014-08-01

    To evaluate differences in mean deviation values in automated perimetry in healthy eyes with multifocal compared to monofocal intraocular lens (IOL) implants. Prospective, age-matched, comparative analysis. Single-center, tertiary referral academic practice. A total of 37 healthy eyes in 37 patients with bilateral multifocal (n=22) or monofocal (n=15) IOL implants were studied. INTERVENTION/OBSERVATION PROCEDURE: Humphrey Visual Field 10-2 testing was performed on all patients. Mean deviation (MD) and pattern standard deviation (PSD) numerical values were evaluated and compared between groups. The average MD was -2.84 dB (SD 2.32) for the multifocal IOL group and -0.97 dB (SD 1.58) for the monofocal IOL group (P=.006). There was no significant difference in PSD between the 2 groups (P=.99). Eyes that had the visual field 10-2 testing≥6 months from time of IOL placement showed no improvement in MD when compared to eyes that were tested within 6 months from IOL placement. Multifocal IOL implants cause significant nonspecific reduction in MD values on Humphrey Visual Field 10-2 testing that does not improve with time or neuroadaptation. Multifocal IOL implants may be inadvisable in patients where central visual field reduction may not be tolerated, such as macular degeneration, retinal pigment epithelium changes, and glaucoma. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Computation of temperature elevation in rabbit eye irradiated by 2.45-GHz microwaves with different field configurations.

    PubMed

    Hirata, Akimasa; Watanabe, Soichi; Taki, Masao; Fujiwara, Osamu; Kojima, Masami; Sasaki, Kazuyuki

    2008-02-01

    This study calculated the temperature elevation in the rabbit eye caused by 2.45-GHz near-field exposure systems. First, we calculated specific absorption rate distributions in the eye for different antennas and then compared them with those observed in previous studies. Next, we re-examined the temperature elevation in the rabbit eye due to a horizontally-polarized dipole antenna with a C-shaped director, which was used in a previous study. For our computational results, we found that decisive factors of the SAR distribution in the rabbit eye were the polarization of the electromagnetic wave and antenna aperture. Next, we quantified the eye average specific absorption rate as 67 W kg(-1) for the dipole antenna with an input power density at the eye surface of 150 mW cm(-2), which was specified in the previous work as the minimum cataractogenic power density. The effect of administrating anesthesia on the temperature elevation was 30% or so in the above case. Additionally, the position where maximum temperature in the lens appears is discussed due to different 2.45-GHz microwave systems. That position was found to appear around the posterior of the lens regardless of the exposure condition, which indicates that the original temperature distribution in the eye was the dominant factor.

  13. Visual fields and eye morphology support color vision in a color-changing crab-spider.

    PubMed

    Insausti, Teresita C; Defrize, Jérémy; Lazzari, Claudio R; Casas, Jérôme

    2012-03-01

    Vision plays a major role in many spiders, being involved in prey hunting, orientation or substrate choice, among others. In Misumena vatia, which experiences morphological color changes, vision has been reported to be involved in substrate color matching. Electrophysiological evidence reveals that at least two types of photoreceptors are present in this species, but these data are not backed up by morphological evidence. This work analyzes the functional structure of the eyes of this spider and relates it to its color-changing abilities. A broad superposition of the visual field of the different eyes was observed, even between binocular regions of principal and secondary eyes. The frontal space is simultaneously analyzed by four eyes. This superposition supports the integration of the visual information provided by the different eye types. The mobile retina of the principal eyes of this spider is organized in three layers of three different types of rhabdoms. The third and deepest layer is composed by just one large rhabdom surrounded by dark screening pigments that limit the light entry. The three pairs of secondary eyes have all a single layer of rhabdoms. Our findings provide strong support for an involvement of the visual system in color matching in this spider. Copyright © 2011 Elsevier Ltd. All rights reserved.

  14. Temporal visual field defects are associated with monocular inattention in chiasmal pathology.

    PubMed

    Fledelius, Hans C

    2009-11-01

    Chiasmal lesions have been shown to give rise occasionally to uni-ocular temporal inattention, which cannot be compensated for by volitional eye movement. This article describes the assessments of 46 such patients with chiasmal pathology. It aims to determine the clinical spectrum of this disorder, including interference with reading. Retrospective consecutive observational clinical case study over a 7-year period comprising 46 patients with chiasmal field loss of varying degrees. Observation of reading behaviour during monocular visual acuity testing ascertained from consecutive patients who appeared unable to read optotypes on the temporal side of the chart. Visual fields were evaluated by kinetic (Goldmann) and static (Octopus) techniques. Five patients who clearly manifested this condition are presented in more detail. The results of visual field testing were related to absence or presence of uni-ocular visual inattentive behaviour for distance visual acuity testing and/or reading printed text. Despite normal eye movements, the 46 patients making up the clinical series perceived only optotypes in the nasal part of the chart, in one eye or in both, when tested for each eye in turn. The temporal optotypes were ignored, and this behaviour persisted despite instruction to search for any additional letters temporal to those, which had been seen. This phenomenon of unilateral visual inattention held for both eyes in 18 and was unilateral in the remaining 28 patients. Partial or full reversibility after treatment was recorded in 21 of the 39 for whom reliable follow-up data were available. Reading a text was affected in 24 individuals, and permanently so in six. A neglect-like spatial unawareness and a lack of cognitive compensation for varying degrees of temporal visual field loss were present in all the patients observed. Not only is visual field loss a feature of chiasmal pathology, but the higher visual function of affording attention within the temporal visual field by means of using conscious thought to invoke appropriate compensatory eye movement was also absent. This suggests the possibility of 'trans-synaptic dysfunction' caused by loss of visual input to higher visual centres. When inattention to the temporal side is manifest on monocular visual testing it should raise the suspicion of chiasmal pathology.

  15. Frequency doubling technology perimetry for detection of visual field progression in glaucoma: a pointwise linear regression analysis.

    PubMed

    Liu, Shu; Yu, Marco; Weinreb, Robert N; Lai, Gilda; Lam, Dennis Shun-Chiu; Leung, Christopher Kai-Shun

    2014-05-02

    We compared the detection of visual field progression and its rate of change between standard automated perimetry (SAP) and Matrix frequency doubling technology perimetry (FDTP) in glaucoma. We followed prospectively 217 eyes (179 glaucoma and 38 normal eyes) for SAP and FDTP testing at 4-month intervals for ≥36 months. Pointwise linear regression analysis was performed. A test location was considered progressing when the rate of change of visual sensitivity was ≤-1 dB/y for nonedge and ≤-2 dB/y for edge locations. Three criteria were used to define progression in an eye: ≥3 adjacent nonedge test locations (conservative), any three locations (moderate), and any two locations (liberal) progressed. The rate of change of visual sensitivity was calculated with linear mixed models. Of the 217 eyes, 6.1% and 3.9% progressed with the conservative criteria, 14.5% and 5.6% of eyes progressed with the moderate criteria, and 20.1% and 11.7% of eyes progressed with the liberal criteria by FDTP and SAP, respectively. Taking all test locations into consideration (total, 54 × 179 locations), FDTP detected more progressing locations (176) than SAP (103, P < 0.001). The rate of change of visual field mean deviation (MD) was significantly faster for FDTP (all with P < 0.001). No eyes showed progression in the normal group using the conservative and the moderate criteria. With a faster rate of change of visual sensitivity, FDTP detected more progressing eyes than SAP at a comparable level of specificity. Frequency doubling technology perimetry can provide a useful alternative to monitor glaucoma progression.

  16. Characteristics of eyes with inner retinal cleavage.

    PubMed

    Hwang, Young Hoon; Kim, Yong Yeon; Kim, Hwang Ki; Sohn, Yong Ho

    2015-02-01

    Inner retinal cleavage can be misdiagnosed as a glaucomatous retinal nerve fiber layer (RNFL) defect. This study was performed to characterize eyes with inner retinal cleavage. Inner retinal cleavage is defined as the appearance of a dark spindle-shaped space between the nerve fibers. Patients who presented at our institution with inner retinal cleavage were enrolled in the study. All participants were evaluated by fundus examination, visual field testing with standard automated perimetry, and optical coherence tomography (OCT) imaging. A total of 15 eyes of 11 subjects with inner retinal cleavage were included in the study. The median age of the subjects was 57 years (age range, 30-67 years). In each case, inner retinal cleavage was located adjacent to retinal blood vessels. Tissue bridging the cleavage area was observed in ten eyes. Six eyes had epiretinal membranes (ERMs), two eyes had glaucoma, and one eye had ERM in addition to glaucoma. Six eyes with inner retinal cleavage without combined ocular abnormalities had highly myopic refractive error (-6.50 to -8.50 diopters). Cross-sectional OCT images of the areas of inner retinal cleavage demonstrated defects with irregular margins and empty spaces in the inner layers of the retina. During the follow-up period, no eye showed changes in inner retinal layer cleavage or visual field sensitivity. Inner retinal cleavage was found in eyes with high myopia or ERMs. Inner retinal cleavage was associated with structural changes distinct from those associated with glaucomatous RNFL defects.

  17. Anterior segment photography in pediatric eyes using the Lytro light field handheld noncontact camera.

    PubMed

    Marcus, Inna; Tung, Irene T; Dosunmu, Eniolami O; Thiamthat, Warakorn; Freedman, Sharon F

    2013-12-01

    To compare anterior segment findings identified in young children using digital photographic images from the Lytro light field camera to those observed clinically. This was a prospective study of children <9 years of age with an anterior segment abnormality. Clinically observed anterior segment examination findings for each child were recorded and several digital images of the anterior segment of each eye captured with the Lytro camera. The images were later reviewed by a masked examiner. Sensitivity of abnormal examination findings on Lytro imaging was calculated and compared to the clinical examination as the gold standard. A total of 157 eyes of 80 children (mean age, 4.4 years; range, 0.1-8.9) were included. Clinical examination revealed 206 anterior segment abnormalities altogether: lids/lashes (n = 21 eyes), conjunctiva/sclera (n = 28 eyes), cornea (n = 71 eyes), anterior chamber (n = 14 eyes), iris (n = 43 eyes), and lens (n = 29 eyes). Review of Lytro photographs of eyes with clinically diagnosed anterior segment abnormality correctly identified 133 of 206 (65%) of all abnormalities. Additionally, 185 abnormalities in 50 children were documented at examination under anesthesia. The Lytro camera was able to document most abnormal anterior segment findings in un-sedated young children. Its unique ability to allow focus change after image capture is a significant improvement on prior technology. Copyright © 2013 American Association for Pediatric Ophthalmology and Strabismus. Published by Mosby, Inc. All rights reserved.

  18. Ultra-wide-field autofluorescence imaging in non-traumatic rhegmatogenous retinal detachment

    PubMed Central

    Witmer, M T; Cho, M; Favarone, G; Paul Chan, R V; D'Amico, D J; Kiss, S

    2012-01-01

    Purpose Rhegmatogenous retinal detachment (RRD) affects the function of the retina before and after surgical repair. We investigated ultra-wide-field autofluorescence (UAF) abnormalities in patients with acute RRD to improve our understanding of the functional changes in the retina before and after surgery. Methods In this retrospective study, we present the UAF imaging findings of 16 patients with acute, non-traumatic RRD. Imaging was obtained with the Optos 200 Tx (Optos) in 14 eyes preoperatively and in 12 eyes postoperatively. Twelve eyes had RRDs that involved the macula (group A), whereas four eyes had macula-sparing RRDs (group B). Results All patients (100%) with bullous retinal detachments demonstrated hypofluorescence over the area of retinal detachment. A hyperfluorescent leading edge (HLE) to the retinal detachment was observed preoperatively in 100% of eyes in group A and 75% of eyes in group B. Preoperative UAF through the fovea of group A eyes was normal (30%), hypofluorescent (50%) or hyperfluorescent (20%). In all patients with a HLE preoperatively, the HLE resolved by the 1-month postoperative visit. A residual line of demarcation remained in 8 of the 12 eyes (67%). In group A eyes, postoperative granular autofluorescent changes were present in four of the nine (44%) eyes, and were associated with worse preoperative (P=0.04) and postoperative (P=0.09) visual acuity. Conclusion UAF imaging reveals abnormalities in RRDs that allow excellent demarcation of the extent of the retinal detachment and assist in preoperative characterization of the detachment and postoperative counselling. PMID:22722489

  19. Zebrafish mab21l2 is specifically expressed in the presumptive eye and tectum from early somitogenesis onwards.

    PubMed

    Kudoh, T; Dawid, I B

    2001-11-01

    Random screening for tissue specific genes in zebrafish by in situ hybridization led us to isolate a gene which showed highly restricted expression in the developing eyes and midbrain at somitogenesis stages. This gene was very similar to mouse and human mab21l2. The characteristic expression pattern of mab21l2 facilitates a detailed description of the morphogenesis of the eyes and midbrain in the zebrafish. In the eye field, mab21l2 expression illustrates the transformation of the eye field to form two separate eyes in the anterior neural plate. Mab21l2 staining in the cyclopic mutants, cyc and oep, exhibited incomplete splitting of the eye primodium. In the midbrain, mab21l2 is expressed in the tectum, and its expression follows the expansion of the tectal region. In mutants affecting the mid-hindbrain boundary (MHB), mab21l2 expression is affected differentially. In the noi/pax2.1 mutant, mab21l2 is down-regulated and the size of the tectum remains small, whereas in the ace/fgf8 mutant, mab21l2 expression persists although the shape of the tectum is altered.

  20. Eye Movements in Risky Choice

    PubMed Central

    Hermens, Frouke; Matthews, William J.

    2015-01-01

    Abstract We asked participants to make simple risky choices while we recorded their eye movements. We built a complete statistical model of the eye movements and found very little systematic variation in eye movements over the time course of a choice or across the different choices. The only exceptions were finding more (of the same) eye movements when choice options were similar, and an emerging gaze bias in which people looked more at the gamble they ultimately chose. These findings are inconsistent with prospect theory, the priority heuristic, or decision field theory. However, the eye movements made during a choice have a large relationship with the final choice, and this is mostly independent from the contribution of the actual attribute values in the choice options. That is, eye movements tell us not just about the processing of attribute values but also are independently associated with choice. The pattern is simple—people choose the gamble they look at more often, independently of the actual numbers they see—and this pattern is simpler than predicted by decision field theory, decision by sampling, and the parallel constraint satisfaction model. © 2015 The Authors. Journal of Behavioral Decision Making published by John Wiley & Sons Ltd. PMID:27522985

  1. Looking into the water with oblique head tilting: revision of the aerial binocular imaging of underwater objects.

    PubMed

    Horváth, Gábor; Buchta, Krisztián; Varjú, Dezsö

    2003-06-01

    It is a well-known phenomenon that when we look into the water with two aerial eyes, both the apparent position and the apparent shape of underwater objects are different from the real ones because of refraction at the water surface. Earlier studies of the refraction-distorted structure of the underwater binocular visual field of aerial observers were restricted to either vertically or horizontally oriented eyes. We investigate a generalized version of this problem: We calculate the position of the binocular image point of an underwater object point viewed by two arbitrarily positioned aerial eyes, including oblique orientations of the eyes relative to the flat water surface. Assuming that binocular image fusion is performed by appropriate vergent eye movements to bring the object's image onto the foveas, the structure of the underwater binocular visual field is computed and visualized in different ways as a function of the relative positions of the eyes. We show that a revision of certain earlier treatments of the aerial imaging of underwater objects is necessary. We analyze and correct some widespread erroneous or incomplete representations of this classical geometric optical problem that occur in different textbooks. Improving the theory of aerial binocular imaging of underwater objects, we demonstrate that the structure of the underwater binocular visual field of aerial observers distorted by refraction is more complex than has been thought previously.

  2. A wearable navigation display can improve attentiveness to the surgical field.

    PubMed

    Stewart, James; Billinghurst, Mark

    2016-06-01

    Surgical navigation is typically shown on a computer display that is distant from the patient, making it difficult for the surgeon to watch the patient while performing a guided task. We investigate whether a light-weight, untracked, wearable display (such as Google Glass, which has the same size and weight as corrective glasses) can improve attentiveness to the surgical field in a simulated surgical task. Three displays were tested: a computer monitor; a peripheral display above the eye; and a through-the-lens display in front of the eye. Twelve subjects performed a task to position and orient a tracked tool on a plastic femur. Both wearable displays were tested on the dominant and non-dominant eyes of each subject. Attentiveness during the task was measured by the time taken to respond to randomly illuminated LEDs on the femur. Attentiveness was improved with the wearable displays at the cost of a decrease in accuracy. The through-the-lens display performed better than the peripheral display. The peripheral display performed better when on the dominant eye, while the through-the-lens display performed better when on the non-dominant eye. Attentiveness to the surgical field can be improved with the use of a light-weight, untracked, wearable display. A through-the-lens display performs better than a peripheral display, and both perform better than a computer monitor. Eye dominance should be considered when positioning the display.

  3. A Study of the Effectiveness of the Army’s National Advertising Expenditures. Volume 3. Appendices.

    DTIC Science & Technology

    1981-08-31

    RUTO-1 ENTTIVLY UGGE’ST2 A TF1 :P-FEF: MODEL OF THE FORM P =17 0 ANt’ DELAY I Figure A.8.3.1. Cross-Correlations CAT I-Ill Exams (Adjusted) vs. Youth...Short Term Objectives i1 I] 80 DATE ACTUAL VALUE WITTED VALVE PLOT *=ACTUAL +=ITTED 76 04 .1559 -. 3159 ’% 7605 .1959 -.2163 76r, 6 -. 2984E-01 .5549

  4. Eye movement perimetry in glaucoma.

    PubMed

    Trope, G E; Eizenman, M; Coyle, E

    1989-08-01

    Present-day computerized perimetry is often inaccurate and unreliable owing to the need to maintain central fixation over long periods while repressing the normal response to presentation of peripheral stimuli. We tested a new method of perimetry that does not require prolonged central fixation. During this test eye movements were encouraged on presentation of a peripheral target. Twenty-three eyes were studied with an Octopus perimeter, with a technician monitoring eye movements. The sensitivity was 100% and the specificity 23%. The low specificity was due to the technician's inability to accurately monitor small eye movements in the central 6 degrees field. If small eye movements are monitored accurately with an eye tracker, eye movement perimetry could become an alternative method to standard perimetry.

  5. The relationship between better-eye and integrated visual field mean deviation and visual disability.

    PubMed

    Arora, Karun S; Boland, Michael V; Friedman, David S; Jefferys, Joan L; West, Sheila K; Ramulu, Pradeep Y

    2013-12-01

    To determine the extent of difference between better-eye visual field (VF) mean deviation (MD) and integrated VF (IVF) MD among Salisbury Eye Evaluation (SEE) subjects and a larger group of glaucoma clinic subjects and to assess how those measures relate to objective and subjective measures of ability/performance in SEE subjects. Retrospective analysis of population- and clinic-based samples of adults. A total of 490 SEE and 7053 glaucoma clinic subjects with VF loss (MD ≤-3 decibels [dB] in at least 1 eye). Visual field testing was performed in each eye, and IVF MD was calculated. Differences between better-eye and IVF MD were calculated for SEE and clinic-based subjects. In SEE subjects with VF loss, models were constructed to compare the relative impact of better-eye and IVF MD on driving habits, mobility, self-reported vision-related function, and reading speed. Difference between better-eye and IVF MD and relationship of better-eye and IVF MD with performance measures. The median difference between better-eye and IVF MD was 0.41 dB (interquartile range [IQR], -0.21 to 1.04 dB) and 0.72 dB (IQR, 0.04-1.45 dB) for SEE subjects and clinic-based patients with glaucoma, respectively, with differences of ≥ 2 dB between the 2 MDs observed in 9% and 18% of the groups, respectively. Among SEE subjects with VF loss, both MDs demonstrated similar associations with multiple ability and performance metrics as judged by the presence/absence of a statistically significant association between the MD and the metric, the magnitude of observed associations (odds ratios, rate ratios, or regression coefficients associated with 5-dB decrements in MD), and the extent of variability in the metric explained by the model (R(2)). Similar associations of similar magnitude also were noted for the subgroup of subjects with glaucoma and subjects in whom better-eye and IVF MD differed by ≥ 2 dB. The IVF MD rarely differs from better-eye MD, and similar associations between VF loss and visual disability are obtained using either MD. Unlike better-eye MD, IVF measurements require extra software/calculation. As such, information from studies using better-eye MD can be more easily integrated into clinical decision-making, making better-eye MD a robust and meaningful method for reporting VF loss severity. Copyright © 2013 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  6. Syringomyelia presenting with unilateral optic neuropathy: a case report.

    PubMed

    Ngoo, Qi Zhe; Tai, Evelyn Li Min; Wan Hitam, Wan Hazabbah

    2017-01-01

    In this case report, we present two cases of syringomyelia with optic neuropathy. In Case 1, a 36-year-old Malay lady presented to our clinic with acute onset of blurring of vision in her left eye that she experienced since past 1 month. She was diagnosed with syringomyelia 12 years ago and was on conservative management. Her visual acuity was 6/6 in the right eye and counting fingers at 1 m in the left. There was a positive relative afferent pupillary defect in her left eye. Optic nerve functions of her left eye were reduced. Visual field showed a left inferior field defect. Her extraocular muscle movements were full. Magnetic resonance imaging of the brain and spine showed syringomyelia at the level of C2-C6 and T2-T9. Both of her optic nerves were normal. Her condition improved with intravenous and oral corticosteroids. In Case 2, a 44-year-old Malay lady presented to our clinic with a progressive central scotoma in her right eye that she experienced since past 1 month. She had previous history of recurrent episodes of weakness in both of her lower limbs from past 8 months. Visual acuity in her right and left eye was 6/9 and 6/6, respectively. The relative afferent pupillary defect in her right eye was positive. Optic nerve functions of her right eye were affected. Visual field showed a central scotoma in her right eye. Her extraocular muscle movements were full. Fundoscopy of her right eye showed a pale optic disc. Her left eye fundus was normal. Magnetic resonance imaging of the brain and spine showed syringomyelia at T3-T6. Both of her optic nerves were normal. A diagnosis of syringomyelia with right optic atrophy was performed. Her condition improved with intravenous and oral corticosteroids. Optic neuropathy is a rare neuro-ophthalmic manifestation in patients with syringomyelia. Prompt diagnosis and timely management are essential to avoid a poor visual outcome. Intravenous corticosteroids are beneficial in the treatment of early optic neuropathy in syringomyelia.

  7. Advanced pigment dispersion glaucoma secondary to phakic intraocular collamer lens implant.

    PubMed

    Ye, Clara; Patel, Cajal K; Momont, Anna C; Liu, Yao

    2018-06-01

    We report a case of pigment dispersion glaucoma secondary to uncomplicated phakic intraocular collamer lens (ICL) (Visian ICL™, Staar Inc., Monrovia, CA) implant that resulted in advanced visual field loss. A 50-year-old man presented for routine follow-up status post bilateral phakic intraocular collamer lens (ICL) placement 8 years earlier. He was incidentally found to have a decline in visual acuity from an anterior subcapsular cataract and elevated intraocular pressure (IOP) in the left eye. There were signs of pigment dispersion and no evidence of angle closure. Diffuse optic nerve thinning was consistent with advanced glaucomatous visual field defects. Pigment dispersion was also present in the patient's right eye, but without elevated IOP or visual field defects. The patient was treated with topical glaucoma medications and the phakic ICL in the left eye was removed concurrently with cataract surgery to prevent further visual field loss. Pigment dispersion glaucoma is a serious adverse outcome after phakic ICL implantation and regular post-operative monitoring may prevent advanced visual field loss.

  8. Millimeter spatial resolution in vivo sodium MRI of the human eye at 7 T using a dedicated radiofrequency transceiver array.

    PubMed

    Wenz, Daniel; Kuehne, Andre; Huelnhagen, Till; Nagel, Armin M; Waiczies, Helmar; Weinberger, Oliver; Oezerdem, Celal; Stachs, Oliver; Langner, Soenke; Seeliger, Erdmann; Flemming, Bert; Hodge, Russell; Niendorf, Thoralf

    2018-08-01

    The aim of this study was to achieve millimeter spatial resolution sodium in vivo MRI of the human eye at 7 T using a dedicated six-channel transceiver array. We present a detailed description of the radiofrequency coil design, along with electromagnetic field and specific absorption ratio simulations, data validation, and in vivo application. Electromagnetic field and specific absorption ratio simulations were performed. Transmit field uniformity was optimized by using a multi-objective genetic algorithm. Transmit field mapping was conducted using a phase-sensitive method. An in vivo feasibility study was carried out with 3-dimensional density-adapted projection reconstruction imaging technique. Measured transmit field distribution agrees well with the one obtained from simulations. The specific absorption ratio simulations confirm that the radiofrequency coil is safe for clinical use. Our radiofrequency coil is light and conforms to an average human head. High spatial resolution (nominal 1.4 and 1.0 mm isotropic) sodium in vivo images of the human eye were acquired within scan times suitable for clinical applications (∼ 10 min). Three most important eye compartments in the context of sodium physiology were clearly delineated in all of the images: the vitreous humor, the aqueous humor, and the lens. Our results provide encouragement for further clinical studies. The implications for research into eye diseases including ocular melanoma, cataract, and glaucoma are discussed. Magn Reson Med 80:672-684, 2018. © 2018 International Society for Magnetic Resonance in Medicine. © 2018 International Society for Magnetic Resonance in Medicine.

  9. Truly simultaneous SS-OCT of the anterior and posterior human eye with full anterior chamber and 50° retinal field of views (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    McNabb, Ryan P.; Viehland, Christian; Keller, Brenton; Vann, Robin R.; Izatt, Joseph A.; Kuo, Anthony N.

    2017-02-01

    Optical coherence tomography (OCT) has revolutionized clinical observation of the eye and is an indispensable part of the modern ophthalmic practice. Unlike many other ophthalmic imaging techniques, OCT provides three-dimensional information about the imaged eye. However, conventional clinical OCT systems image only the anterior or the posterior eye during a single acquisition. Newer OCT systems have begun to image both during the same acquisition but with compromises such as limited field of view in the posterior eye or requiring rapid switching between the anterior and posterior eye during the scan. We describe here the development and demonstration of an OCT system with truly simultaneous imaging of both the anterior and posterior eye capable of imaging the full anterior chamber width and 50° on the retina (macula, optic nerve, and arcades). The whole eye OCT system was developed using custom optics and optomechanics. Polarization was utilized to separate the imaging channels. We utilized a 200kHz swept-source laser (Axsun Technologies) centered at 1040±50nm of bandwidth. The clock signal generated by the laser was interpolated 4x to generate 5504 samples per laser sweep. With the whole eye OCT system, we simultaneously acquired anterior and posterior segments with repeated B-scans as well as three-dimensional volumes from seven healthy volunteers (other than refractive error). On three of these volunteers, whole eye OCT and partial coherence interferometry (LenStar PCI, Haag-Streit) were used to measure axial eye length. We measured a mean repeatability of ±47µm with whole eye OCT and a mean difference from PCI of -68µm.

  10. Detecting early functional damage in glaucoma suspect and ocular hypertensive patients with the multifocal VEP technique.

    PubMed

    Thienprasiddhi, Phamornsak; Greenstein, Vivienne C; Chu, David H; Xu, Li; Liebmann, Jeffrey M; Ritch, Robert; Hood, Donald C

    2006-08-01

    To determine whether the multifocal visual evoked potential (mfVEP) technique can detect early functional damage in ocular hypertensive (OHT) and glaucoma suspect (GS) patients with normal standard achromatic automated perimetry (SAP) results. Twenty-five GS patients (25 eyes), 25 patients with OHT (25 eyes), and 50 normal controls (50 eyes) were enrolled in this study. All GS, OHT and normal control eyes had normal SAP as defined by a pattern standard deviation and mean deviation within the 95% confidence interval and a glaucoma hemifield test within normal limits on the Humphrey visual field 24-2 program. Eyes with GS had optic disc changes consistent with glaucoma with or without raised intraocular pressure (IOP), and eyes with OHT showed no evidence of glaucomatous optic neuropathy and IOPs >or=22 mm Hg. Monocular mfVEPs were obtained from both eyes of each subject using a pattern-reversal dartboard array with 60 sectors. The entire display had a radius of 22.3 degrees. The mfVEPs, for each eye, were defined as abnormal when either the monocular or interocular probability plot had a cluster of 3 or more contiguous points with P<0.05 and at least 2 of these points with P<0.01. The mfVEP results were abnormal in 4% of the eyes from normal subjects. Abnormal mfVEPs were detected in 20% of the eyes of GS patients and 16% of the eyes of OHT patients. Significantly more mfVEP abnormalities were detected in GS patients than in normal controls. However, there was no significant difference in mfVEP results between OHT patients and normal controls. The mfVEP technique can detect visual field deficits in a minority of eyes with glaucomatous optic disks and normal SAP results.

  11. Optimizations and Applications in Head-Mounted Video-Based Eye Tracking

    ERIC Educational Resources Information Center

    Li, Feng

    2011-01-01

    Video-based eye tracking techniques have become increasingly attractive in many research fields, such as visual perception and human-computer interface design. The technique primarily relies on the positional difference between the center of the eye's pupil and the first-surface reflection at the cornea, the corneal reflection (CR). This…

  12. Opening a Window into Reading Development: Eye Movements' Role Within a Broader Literacy Research Framework.

    PubMed

    Miller, Brett; O'Donnell, Carol

    2013-01-01

    The cumulative body of eye movement research provides significant insight into how readers process text. The heart of this work spans roughly 40 years reflecting the maturity of both the topics under study and experimental approaches used to investigate reading. Recent technological advancements offer increased flexibility to the field providing the potential to more concertedly study reading and literacy from an individual differences perspective. Historically, eye movement research focused far less on developmental issues related to individual differences in reading; however, this issue and the broader change it represents signal a meaningful transition inclusive of individual differences. The six papers in this special issue signify the recent, increased attention to and recognition of eye movement research's transition to emphasize individual differences in reading while appreciating early contributions (e.g., Rayner, 1986) in this direction. We introduce these six papers and provide some historical context for the use of eye movement methodology to examine reading and context for the eye movement field's early transition to examining individual differences, culminating in future research recommendations.

  13. Eye Velocity Gain Fields in MSTd During Optokinetic Stimulation

    PubMed Central

    Brostek, Lukas; Büttner, Ulrich; Mustari, Michael J.; Glasauer, Stefan

    2015-01-01

    Lesion studies argue for an involvement of cortical area dorsal medial superior temporal area (MSTd) in the control of optokinetic response (OKR) eye movements to planar visual stimulation. Neural recordings during OKR suggested that MSTd neurons directly encode stimulus velocity. On the other hand, studies using radial visual flow together with voluntary smooth pursuit eye movements showed that visual motion responses were modulated by eye movement-related signals. Here, we investigated neural responses in MSTd during continuous optokinetic stimulation using an information-theoretic approach for characterizing neural tuning with high resolution. We show that the majority of MSTd neurons exhibit gain-field-like tuning functions rather than directly encoding one variable. Neural responses showed a large diversity of tuning to combinations of retinal and extraretinal input. Eye velocity-related activity was observed prior to the actual eye movements, reflecting an efference copy. The observed tuning functions resembled those emerging in a network model trained to perform summation of 2 population-coded signals. Together, our findings support the hypothesis that MSTd implements the visuomotor transformation from retinal to head-centered stimulus velocity signals for the control of OKR. PMID:24557636

  14. The Advanced Glaucoma Intervention Study (AGIS): 14. Distinguishing progression of glaucoma from visual field fluctuations.

    PubMed

    Kim, Jonghyeon; Dally, Leonard G; Ederer, Fred; Gaasterland, Douglas E; VanVeldhuisen, Paul C; Blackwell, Beth; Sullivan, E Kenneth; Prum, Bruce; Shafranov, George; Beck, Allen; Spaeth, George L

    2004-11-01

    To determine the least worsening of a visual field (VF) and the least number of confirming tests needed to identify progression of glaucomatous VF defects. Cohort study of participants in a clinical trial. Seven hundred fifty-two eyes of 565 patients with advanced glaucoma. Visual field tests were quantified with the Advanced Glaucoma Intervention Study (AGIS) VF defect score and the Humphrey Field Analyzer mean deviation (MD). Follow-up was 8 to 13 years. Two measures based on the AGIS VF defect score: (1) sustained decrease of VF (SDVF), a worsening from baseline by 2 (alternatively, 3 or 4) or more units and sustained for 2 (alternatively, 3) consecutive 6-month visits and (2) after the occurrence of SDVF, the average percent of eyes with worsening by 2 (alternatively, 3 or 4) or more units from baseline. Two similar measures based on MD. Based on the original AGIS criteria for SDVF (a worsening of 4 units in the AGIS score sustained during 3 consecutive 6-month visits), 31% of eyes had an SDVF. The percent of eyes with a sustained event increases by approximately 10% when either the minimum number of units of field loss or the minimum number of 6-month visits during which the loss is sustained decreases by 1. During 3 years of follow-up after a sustained event, a worsening of at least 2 units was found in 72% of eyes that had a 2-visit sustained event. The same worsening was found in 84% of eyes that had a 3-visit sustained event. Through the next 10 years after a sustained event, based on worsening of 2, 3, or 4 units at 2 or 3 consecutive tests, the loss reoccurred, on average, in >/=75% of study eyes. Results for MD are similar. In patients with advanced glaucoma, a single confirmatory test 6 months after a VF worsening indicates with at least 72% probability a persistent defect when the worsening is defined by at least 2 units of AGIS score or by at least 2 decibels of MD. When the number of confirmatory tests is increased from 1 to 2, the percentage of eyes that show a persistent defect increases from 72% to 84%.

  15. Effects of a Blacklight Visual Field on Eye-Contact Training of Spastic Cerebral Palsied Children.

    ERIC Educational Resources Information Center

    Poland, D. J.; Doebler, L, K.

    1980-01-01

    Four subjects, aged six to seven, identified as visually impaired, were given training in making eye contact with a stimulus under both white and black light visual field. All subjects performed better under the black light condition, even overcoming the expected practice effect when white light training followed black light training. (Author/SJL)

  16. PERCEPTION AND TELEVISION--PHYSIOLOGICAL FACTORS OF TELEVISION VIEWING.

    ERIC Educational Resources Information Center

    GUBA, EGON; AND OTHERS

    AN EXPERIMENTAL SYSTEM WAS DEVELOPED FOR RECORDING EYE-MOVEMENT DATA. RAW DATA WERE IN THE FORM OF MOTION PICTURES TAKEN OF THE MONITOR OF A CLOSED LOOP TELEVISION SYSTEM. A TELEVISION CAMERA WAS MOUNTED ON THE SUBJECTS' FIELD OF VIEW. THE EYE MARKER APPEARED AS A SMALL SPOT OF LIGHT AND INDICATED THE POINT IN THE VISUAL FIELD AT WHICH THE SUBJECT…

  17. Shaping magnetic fields to direct therapy to ears and eyes.

    PubMed

    Shapiro, B; Kulkarni, S; Nacev, A; Sarwar, A; Preciado, D; Depireux, D A

    2014-07-11

    Magnetic fields have the potential to noninvasively direct and focus therapy to disease targets. External magnets can apply forces on drug-coated magnetic nanoparticles, or on living cells that contain particles, and can be used to manipulate them in vivo. Significant progress has been made in developing and testing safe and therapeutic magnetic constructs that can be manipulated by magnetic fields. However, we do not yet have the magnet systems that can then direct those constructs to the right places, in vivo, over human patient distances. We do not yet know where to put the external magnets, how to shape them, or when to turn them on and off to direct particles or magnetized cells-in blood, through tissue, and across barriers-to disease locations. In this article, we consider ear and eye disease targets. Ear and eye targets are too deep and complex to be targeted by a single external magnet, but they are shallow enough that a combination of magnets may be able to direct therapy to them. We focus on how magnetic fields should be shaped (in space and time) to direct magnetic constructs to ear and eye targets.

  18. Variation of axial and oblique astigmatism with accommodation across the visual field

    PubMed Central

    Liu, Tao; Thibos, Larry N.

    2017-01-01

    In this study we investigated the impact of accommodation on axial and oblique astigmatism along 12 meridians of the central 30° of visual field and explored the compensation of corneal first-surface astigmatism by the remainder of the eye's optical system. Our experimental evidence revealed no systematic effect of accommodation on either axial or oblique astigmatism for two adult populations (myopic and emmetropic eyes). Although a few subjects exhibited systematic changes in axial astigmatism during accommodation, the dioptric value of these changes was much smaller than the amount of accommodation. For most subjects, axial and oblique astigmatism of the whole eye are both less than for the cornea alone, which indicates a compensatory role for internal optics at all accommodative states in both central and peripheral vision. A new method for determining the eye's optical axis based on visual field maps of oblique astigmatism revealed that, on average, the optical axis is 4.8° temporal and 0.39° superior to the foveal line-of-sight in object space, which agrees with previous results obtained by different methodologies and implies that foveal astigmatism includes a small amount of oblique astigmatism (0.06 D on average). Customized optical models of each eye revealed that oblique astigmatism of the corneal first surface is negligible along the pupillary axis for emmetropic and myopic eyes. Individual variation in the eye's optical axis is due in part to misalignment of the corneal and internal components that is consistent with tilting of the crystalline lens relative to the pupillary axis. PMID:28362902

  19. Visual acuity and visual field impairment in Usher syndrome.

    PubMed

    Edwards, A; Fishman, G A; Anderson, R J; Grover, S; Derlacki, D J

    1998-02-01

    To determine the extent of visual acuity and visual field impairment in patients with types 1 and 2 Usher syndrome. The records of 53 patients with type 1 and 120 patients with type 2 Usher syndrome were reviewed for visual acuity and visual field area at their most recent visit. Visual field areas were determined by planimetry of the II4e and V4e isopters obtained with a Goldmann perimeter. Both ordinary and logistic regression models were used to evaluate differences in visual acuity and visual field impairment between patients with type 1 and type 2 Usher syndrome. The difference in visual acuity of the better eye between patients with type 1 and type 2 varied by patient age (P=.01, based on a multiple regression model). The maximum difference in visual acuity between the 2 groups occurred during the third and fourth decades of life (with the type 1 patients being more impaired), while more similar acuities were seen in both younger and older patients. Fifty-one percent (n=27) of the type 1 patients had a visual acuity of 20/40 or better in at least 1 eye compared with 72% (n=87) of the type 2 patients (age-adjusted odds ratio, 3.9). Visual field area to both the II4e (P=.001) and V4e (P<.001) targets was more impaired in the better eye of type 1 patients than type 2 patients. A concentric central visual field greater than 20 degrees in at least 1 eye was present in 20 (59%) of the available 34 visual fields of type 1 patients compared with 70 (67%) of the available 104 visual fields of type 2 patients (age-adjusted odds ratio, 2.9) with the V4e target and in 6 (21%) of the available 29 visual fields of type 1 patients compared with 36 (38%) of the available 94 visual fields of type 2 patients (age-adjusted odds ratio, 4.9) with the II4e target. The fraction of patients who had a visual acuity of 20/40 or better and a concentric central visual field greater than 20 degrees to the II4e target in at least 1 eye was 17% (n=5) in the type 1 patients and 35% (n=33) in the type 2 patients (age-adjusted odds ratio, 3.9). Visual acuity and visual field area were more impaired in patients with type 1 than type 2 Usher syndrome. Of note, 27 of 53 type 1 (51%) and 87 of 120 type 2 (72%) patients had a visual acuity of 20/40 or better in at least 1 eye. These data are useful for overall counseling of patients with Usher syndrome.

  20. [Clinical findings in members of a Czech family with retinitis pigmentosa caused by the c.2426_2427delAG mutation in RPGR].

    PubMed

    Kousal, B; Skalická, P; Diblík, P; Kuthan, P; Langrová, H; Lišková, P

    2013-03-01

    To describe the phenotype of members of the first Czech retinitis pigmentosa family with an identified molecular genetic cause (c.2426_2427delAG in RPGR), followed for more than 13 years. Medical records were reviewed and a detailed ophthalmic examination including spectral-domain optical coherence tomography and full-field and multifocal electroretinography (ERG) was performed in two affected males, three female carriers and one unaffected female. A 22-year-old male who denied suffering from nyctalopia had a best corrected visual acuity (BCVA) of 0.63 in both eyes. Moderate myopia and myopic astigmatism were present bilaterally. Color vision and contrast sensitivity were normal. There was an eccentric constriction of the visual fields that spared the central 20 degrees in both eyes. Fundus examination revealed bilateral pigmentary changes in the mid-periphery. Full-field ERG documented a 10% rod and 20% cone response. The phenotype of his cousin, also aged 22 years, was more severe. He complained of nyctalopia since 12 years of age. His BCVA was 0.3 in the right eye and 0.5 in the left eye. Myopia and astigmatism were present bilaterally. Contrast sensitivity and color vision were severely impaired. Full field ERG was extinct, but some activity on multifocal ERG was still detectable. The constriction of the visual fields reached 5 degrees in both eyes. Fundus examination showed the typical retinitis pigmentosa appearance. All carriers denied that they suffered from nyctalopia, but two of them had decreased BCVA in at least one eye. None exhibited typical bone spicules or a tapetal-like reflex. Significant refractive errors were present in all eyes of the carriers. The finding of moderate or high myopia and astigmatism in males with retinitis pigmentosa as well as refractive errors in female relatives indicates possible X-linked inheritance, which may be especially important in pedigrees where the transmission pattern can not be clearly established. Our study highlights the inter-individual variability in phenotype observed in similar aged patients with identical ORF15 RPGR mutations.

  1. Overcoming ocular drug delivery barriers through the use of physical forces.

    PubMed

    Huang, Di; Chen, Ying-Shan; Rupenthal, Ilva D

    2018-02-15

    Overcoming the physiological barriers in the eye remains a key obstacle in the field of ocular drug delivery. While ocular barriers naturally have a protective function, they also limit drug entry into the eye. Various pharmaceutical strategies, such as novel formulations and physical force-based techniques, have been investigated to weaken these barriers and transport therapeutic agents effectively to both the anterior and the posterior segments of the eye. This review summarizes and discusses the recent research progress in the field of ocular drug delivery with a focus on the application of physical methods, including electrical fields, sonophoresis, and microneedles, which can enhance penetration efficiency by transiently disrupting the ocular barriers in a minimally or non-invasive manner. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. A functional probe with bowtie aperture and bull's eye structure for nanolithograph

    NASA Astrophysics Data System (ADS)

    Wang, Shuo; Li, Xu-Feng; Wang, Qiao; Guo, Ying-Yan; Pan, Shi

    2012-10-01

    The bowtie aperture surrounded by concentric gratings (the bull's eye structure) integrated on the near-field scanning optical microscopy (NSOM) probe (aluminum coated fiber tip) for nanolithography has been investigated using the finite-difference time domain (FDTD) method. By modifying the parameters of the bowtie aperture and the concentric gratings, a maximal field enhancement factor of 391.69 has been achieved, which is 18 times larger than that obtained from the single bowtie aperture. Additionally, the light spot depends on the gap size of the bowtie aperture and can be confined to sub-wavelength. The superiority of the combination of the bowtie aperture and the bull's eye structure is confirmed, and the mechanism for the electric field enhancement in this derived structure is analyzed.

  3. Features of the Retinotopic Representation in the Visual Wulst of a Laterally Eyed Bird, the Zebra Finch (Taeniopygia guttata)

    PubMed Central

    Michael, Neethu; Löwel, Siegrid; Bischof, Hans-Joachim

    2015-01-01

    The visual wulst of the zebra finch comprises at least two retinotopic maps of the contralateral eye. As yet, it is not known how much of the visual field is represented in the wulst neuronal maps, how the organization of the maps is related to the retinal architecture, and how information from the ipsilateral eye is involved in the activation of the wulst. Here, we have used autofluorescent flavoprotein imaging and classical anatomical methods to investigate such characteristics of the most posterior map of the multiple retinotopic representations. We found that the visual wulst can be activated by visual stimuli from a large part of the visual field of the contralateral eye. Horizontally, the visual field representation extended from -5° beyond the beak tip up to +125° laterally. Vertically, a small strip from -10° below to about +25° above the horizon activated the visual wulst. Although retinal ganglion cells had a much higher density around the fovea and along a strip extending from the fovea towards the beak tip, these areas were not overrepresented in the wulst map. The wulst area activated from the foveal region of the ipsilateral eye, overlapped substantially with the middle of the three contralaterally activated regions in the visual wulst, and partially with the other two. Visual wulst activity evoked by stimulation of the frontal visual field was stronger with contralateral than with binocular stimulation. This confirms earlier electrophysiological studies indicating an inhibitory influence of the activation of the ipsilateral eye on wulst activity elicited by stimulating the contralateral eye. The lack of a foveal overrepresentation suggests that identification of objects may not be the primary task of the zebra finch visual wulst. Instead, this brain area may be involved in the processing of visual information necessary for spatial orientation. PMID:25853253

  4. Optic nerve dysfunction during gravity inversion. Visual field abnormalities.

    PubMed

    Sanborn, G E; Friberg, T R; Allen, R

    1987-06-01

    Inversion in a head-down position (gravity inversion) results in an intraocular pressure of 35 to 40 mm Hg in normal subjects. We used computerized static perimetry to measure the visual fields of normal subjects during gravity inversion. There were no visual field changes in the central 6 degrees of the visual field compared with the baseline (preinversion) values. However, when the central 30 degrees of the visual field was tested, reversible visual field defects were found in 11 of 19 eyes. We believe that the substantial elevation of intraocular pressure during gravity inversion may pose potential risks to the eyes, and we recommend that inversion for extended periods of time be avoided.

  5. Relationship Between Optic Nerve Appearance and Retinal Nerve Fiber Layer Thickness as Explored with Spectral Domain Optical Coherence Tomography

    PubMed Central

    Aleman, Tomas S.; Huang, Jiayan; Garrity, Sean T.; Carter, Stuart B.; Aleman, Wendy D.; Ying, Gui-shuang; Tamhankar, Madhura A.

    2014-01-01

    Purpose To study the relationship between the appearance of the optic nerve and the retinal nerve fiber layer (RNFL) thickness determined by spectral domain optical coherence tomography (OCT). Methods Records from patients with spectral domain-OCT imaging in a neuro-ophthalmology practice were reviewed. Eyes with glaucoma/glaucoma suspicion, macular/optic nerve edema, pseudophakia, and with refractive errors > 6D were excluded. Optic nerve appearance by slit lamp biomicroscopy was related to the RNFL thickness by spectral domain-OCT and to visual field results. Results Ninety-one patients (176 eyes; mean age: 49 ± 15 years) were included. Eighty-three eyes (47%) showed optic nerve pallor; 89 eyes (50.6%) showed RNFL thinning (sectoral or average peripapillary). Average peripapillary RNFL thickness in eyes with pallor (mean ± SD = 76 ± 17 μm) was thinner compared to eyes without pallor (91 ± 14 μm, P < 0.001). Optic nerve pallor predicted RNFL thinning with a sensitivity of 69% and a specificity of 75%. Optic nerve appearance predicted RNFL thinning (with a sensitivity and specificity of 81%) when RNFL had thinned by ∼ 40%. Most patients with pallor had RNFL thinning with (66%) or without (25%) visual field loss; the remainder had normal RNFL and fields (5%) or with visual field abnormalities (4%). Conclusions Optic nerve pallor as a predictor of RNFL thinning showed fair sensitivity and specificity, although it is optimally sensitive/specific only when substantial RNFL loss has occurred. Translational Relevance Finding an acceptable relationship between the optic nerve appearance by ophthalmoscopy and spectral domain-OCT RNFL measures will help the clinician's interpretation of the information provided by this technology, which is gaining momentum in neuro-ophthalmic research. PMID:25374773

  6. The Rate of Visual Field Change in the Ocular Hypertension Treatment Study

    PubMed Central

    De Moraes, Carlos Gustavo V.; Gardiner, Stuart K.; Liebmann, Jeffrey M.; Cioffi, George A.; Ritch, Robert; Gordon, Mae O.; Kass, Michael A.

    2012-01-01

    Purpose. To assess the rate of change of visual field (VF) mean deviation (MD) in the Ocular Hypertension Treatment Study (OHTS). Methods. OHTS data were filtered to exclude eyes that had fewer than 10 reliable VFs or less than 5 years of follow-up or that reached a nonglaucomatous endpoint. The rate of change of MD (MDR) was calculated for each eye. Differences were sought between groups of eyes differing in primary open angle glaucoma (POAG) outcome, how POAG was determined, and original randomization. Results. In total, 2609 eyes (1379 participants) met the selection criteria. The mean MDR was −0.08 ± 0.20 dB/y (±SD). POAG eyes (n = 359) had significantly worse MDRs (−0.26 ± 0.36 dB/y) than non-POAG eyes (n = 2250; −0.05 ± 0.14 dB/y; P < 0.001). Eyes that reached POAG endpoints based on only VF change (n = 74; −0.29 ± 0.31 dB/y) or only optic disc change (n = 158; −0.12 ± 0.19 dB/y) had significantly worse MDRs than non-POAG eyes (both P < 0.001). Eyes that reached POAG endpoints for both VF and optic disc change (n = 127) deteriorated more rapidly (−0.42 ± 0.46 dB/y) than eyes showing only VF change (P = 0.017) or only optic disc change (P < 0.001). There was not a significant association between MDR and original OHTS randomization (observe vs. treat, P = 0.168). Conclusions. Eyes that develop POAG have significantly worse MDRs than eyes that do not. Eyes that reached endpoints due to both VF and optic disc change had worse MDRs than eyes displaying change in only one of these. MDR was not significantly associated with randomization, suggesting that MDR may not be the best measure of VF change in early-stage POAG. (ClinicalTrials.gov number, NCT00000125.) PMID:22159015

  7. Relative peripheral refraction in children: twelve-month changes in eyes with different ametropias.

    PubMed

    Lee, Tsui-Tsui; Cho, Pauline

    2013-05-01

    To determine the peripheral refraction of children with different types of ametropias and to evaluate the relationship between central refractive changes, baseline relative peripheral refraction (RPR) and changes in RPR over a 12-month monitoring period. Cycloplegic central and peripheral refraction were performed biannually on the right eyes of children aged 6-9 for 12 months, using an open-view autorefractor. Peripheral refraction were measured along 10°, 20° and 30° from central fixation in both nasal and temporal fields. Refractive data were transposed into M, J0 and J45 vectors for analyses. RPR was determined by subtracting the central measurement from each peripheral measurement. Hyperopic eyes showed relative peripheral myopia while myopic eyes had relative hyperopia across the central 60° horizontal field at baseline. Emmetropic eyes had relative myopia within but showed relative hyperopia beyond the central 30° field. However, there was no significant correlation between central refractive changes and baseline RPR or between changes in central refraction and RPR over twelve months in any refractive groups. Correlations between changes in PR and central myopic shift were found mainly in the nasal field in different groups. In the subgroup analysis on the initially emmetropic and the initially myopic groups, the subgroups with faster myopic progression did not have significantly different RPR from the subgroups with slower progression. The RPR pattern of the initially emmetropic and the initially myopic groups became more asymmetric at the end of the study period with a larger increase in relative hyperopia in the temporal field. RPR patterns were different among hyperopic, emmetropic and myopic eyes. However, baseline RPR and changes in RPR cannot predict changes in central refraction over time. Our results did not provide evidence to support the hypothesis of RPR as a causative factor for myopic central refractive changes in children. Ophthalmic & Physiological Optics © 2013 The College of Optometrists.

  8. Detection of Visual Field Loss in Pituitary Disease: Peripheral Kinetic Versus Central Static

    PubMed Central

    Rowe, Fiona J.; Cheyne, Christopher P.; García-Fiñana, Marta; Noonan, Carmel P.; Howard, Claire; Smith, Jayne; Adeoye, Joanne

    2015-01-01

    Abstract Visual field assessment is an important clinical evaluation for eye disease and neurological injury. We evaluated Octopus semi-automated kinetic peripheral perimetry (SKP) and Humphrey static automated central perimetry for detection of neurological visual field loss in patients with pituitary disease. We carried out a prospective cross-sectional diagnostic accuracy study comparing Humphrey central 30-2 SITA threshold programme with a screening protocol for SKP on Octopus perimetry. Humphrey 24-2 data were extracted from 30-2 results. Results were independently graded for presence/absence of field defect plus severity of defect. Fifty patients (100 eyes) were recruited (25 males and 25 females), with mean age of 52.4 years (SD = 15.7). Order of perimeter assessment (Humphrey/Octopus first) and order of eye tested (right/left first) were randomised. The 30-2 programme detected visual field loss in 85%, the 24-2 programme in 80%, and the Octopus combined kinetic/static strategy in 100% of eyes. Peripheral visual field loss was missed by central threshold assessment. Qualitative comparison of type of visual field defect demonstrated a match between Humphrey and Octopus results in 58%, with a match for severity of defect in 50%. Tests duration was 9.34 minutes (SD = 2.02) for Humphrey 30-2 versus 10.79 minutes (SD = 4.06) for Octopus perimetry. Octopus semi-automated kinetic perimetry was found to be superior to central static testing for detection of pituitary disease-related visual field loss. Where reliant on Humphrey central static perimetry, the 30-2 programme is recommended over the 24-2 programme. Where kinetic perimetry is available, this is preferable to central static programmes for increased detection of peripheral visual field loss. PMID:27928344

  9. Allocation of distinct organ fates from a precursor field requires a shift in expression and function of gene regulatory networks

    PubMed Central

    Zhu, Jinjin; Baker, Luke R.; Bashirullah, Arash

    2018-01-01

    A common occurrence in metazoan development is the rise of multiple tissues/organs from a single uniform precursor field. One example is the anterior forebrain of vertebrates, which produces the eyes, hypothalamus, diencephalon, and telencephalon. Another instance is the Drosophila wing disc, which generates the adult wing blade, the hinge, and the thorax. Gene regulatory networks (GRNs) that are comprised of signaling pathways and batteries of transcription factors parcel the undifferentiated field into discrete territories. This simple model is challenged by two observations. First, many GRN members that are thought to control the fate of one organ are actually expressed throughout the entire precursor field at earlier points in development. Second, each GRN can simultaneously promote one of the possible fates choices while repressing the other alternatives. It is therefore unclear how GRNs function to allocate tissue fates if their members are uniformly expressed and competing with each other within the same populations of cells. We address this paradigm by studying fate specification in the Drosophila eye-antennal disc. The disc, which begins its development as a homogeneous precursor field, produces a number of adult structures including the compound eyes, the ocelli, the antennae, the maxillary palps, and the surrounding head epidermis. Several selector genes that control the fates of the eye and antenna, respectively, are first expressed throughout the entire eye-antennal disc. We show that during early stages, these genes are tasked with promoting the growth of the entire field. Upon segregation to distinct territories within the disc, each GRN continues to promote growth while taking on the additional roles of promoting distinct primary fates and repressing alternate fates. The timing of both expression pattern restriction and expansion of functional duties is an elemental requirement for allocating fates within a single field. PMID:29351292

  10. The Effects of Ramadan Intermittent Fasting (RIF) on Spirometric Data of Stable COPD Patients: A Pilot Study.

    PubMed

    Zouari, Hajer; Latiri, Imed; Mahjoub, Mohamed; Boussarsar, Mohamed; Benzarti, Mohamed; Abdelghani, Ahmed; Ben Saad, Helmi

    2018-03-01

    No previous study has raised the effects of RIF on lung function data of chronic obstructive pulmonary disease (COPD) patients. The objective of the present study was to assess the effects of RIF on spirometric data measured in male patients with a stable COPD. Sixteen patients with stable COPD (mean ± SD of age: 64 ± 7 years) who fasted during Ramadan volunteered to the study. Three sessions (Before-R, End-R, and After-R) were selected for spirometry tests that were consistently performed 2.5-4.5 hr before fasting break. Assessment sessions comprised: forced vital capacity (FVC), 1st s forced expiratory volume (FEV 1 ), FEV 1 /FVC, peak expiratory flow (PEF), maximal mid-expiratory flow (MMEF), and forced expiratory flow rate at the x% of FVC to be exhaled (FEFx%). A reversibility test was performed only during the Before-Ramadan session. Spirometric data were expressed in percentages of local reference values. Findings were analyzed by applying repeated measures analysis of variance. The mean ± SD of the postbronchodilator FEV 1 /FVC ratio and the FEV 1 were, respectively, 0.52 ± 0.14 and 48 ± 19%. The mean ± SD of FEV 1 (Before-R: 47 ± 19, End-R: 45 ± 18, After-R: 44 ± 19%), FVC (Before-R: 73 ± 18, End-R: 71 ± 16, After-R: 69 ± 17%), FEV 1 /FVC (Before-R: 67 ± 16, End-R: 66 ± 16, After-R: 65 ± 16%), PEF (Before-R: 46 ± 19, End-R: 47 ± 22, After-R: 45 ± 21%), MMEF (Before-R: 19 ± 10, End-R: 18 ± 8, After-R: 18 ± 9%), FEF 25% (Before-R: 16 ± 6, End-R: 16 ± 5, After-R: 15 ± 5%), FEF 50% (Before-R: 21 ± 14, End-R: 20 ± 12, After-R: 20 ± 12%) and FEF 75% (Before-R: 27 ± 19, End-R: 27 ± 19, After-R: 27 ± 19%) were not significantly influenced by RIF. RIF did not bring about any significant changes in the spirometric data of stable COPD male patients fasting the 2016 holy month of Ramadan.

  11. Cross shift changes in lung function among bar and restaurant workers before and after implementation of a smoking ban

    PubMed Central

    Skogstad, M; Kjærheim, K; Fladseth, G; Gjølstad, M; Daae, H L; Olsen, R; Molander, P; Ellingsen, D G

    2006-01-01

    Objective To study possible cross shift effects of environmental tobacco smoke (ETS) on pulmonary function among bar and restaurant employees before and after the implementation of a smoking ban in Norway. Methods The study included 93 subjects employed in 13 different establishments in Oslo. They were examined at the beginning and end of a workshift both while ETS exposure was present and when smoking was banned. The mean exposure level of nicotine and total dust before the ban was 28 μg/m3 (range 3–65) and 275 μg/m3 (range 81–506), respectively. Following the smoking ban, the mean level of nicotine and total dust was 0.6 μg/m3 and 77 μg/m3, respectively. Assessment of lung function included dynamic lung volumes and flows. Results The cross shift reduction in forced vital capacity (FVC) among 69 subjects participating in both examinations changed from 81 ml (SD 136) during exposure to ETS to 52 ml (SD 156) (p = 0.24) following the smoking ban. The reduction in forced expired volume in one second (FEV1) during a workshift, was borderline significantly reduced when comparing the situation before and after the intervention, by 89 ml (SD = 132) compared to 46 ml (SD = 152) (p = 0.09), respectively. The reduction in forced mid‐expiratory flow rate (FEF25–75%) changed significantly from 199 ml/s (SD = 372) to 64 ml/s (SD = 307) (p = 0.01). Among 26 non‐smokers and 11 asthmatics, the reduction in FEV1 and FEF25–75% was significantly larger during ETS exposure compared to after the smoking ban. There was an association between the dust concentration and decrease in FEF25–75% before the ban among non‐smokers (p = 0.048). Conclusions This first study of cross shift changes before and after the implementation of a smoking ban in restaurants and bars shows a larger cross shift decrease in lung function before compared with after the implementation of the ban. PMID:16551754

  12. Design and simulation of a superposition compound eye system based on hybrid diffractive-refractive lenses.

    PubMed

    Zhang, Shuqing; Zhou, Luyang; Xue, Changxi; Wang, Lei

    2017-09-10

    Compound eyes offer a promising field of miniaturized imaging systems. In one application of a compound eye, superposition of compound eye systems forms a composite image by superposing the images produced by different channels. The geometric configuration of superposition compound eye systems is achieved by three micro-lens arrays with different pitches and focal lengths. High resolution is indispensable for the practicability of superposition compound eye systems. In this paper, hybrid diffractive-refractive lenses are introduced into the design of a compound eye system for this purpose. With the help of ZEMAX, two superposition compound eye systems with and without hybrid diffractive-refractive lenses were separately designed. Then, we demonstrate the effectiveness of using a hybrid diffractive-refractive lens to improve the image quality.

  13. Difference in Visual Processing Assessed by Eye Vergence Movements

    PubMed Central

    Solé Puig, Maria; Puigcerver, Laura; Aznar-Casanova, J. Antonio; Supèr, Hans

    2013-01-01

    Orienting visual attention is closely linked to the oculomotor system. For example, a shift of attention is usually followed by a saccadic eye movement and can be revealed by micro saccades. Recently we reported a novel role of another type of eye movement, namely eye vergence, in orienting visual attention. Shifts in visuospatial attention are characterized by the response modulation to a selected target. However, unlike (micro-) saccades, eye vergence movements do not carry spatial information (except for depth) and are thus not specific to a particular visual location. To further understand the role of eye vergence in visual attention, we tested subjects with different perceptual styles. Perceptual style refers to the characteristic way individuals perceive environmental stimuli, and is characterized by a spatial difference (local vs. global) in perceptual processing. We tested field independent (local; FI) and field dependent (global; FD) observers in a cue/no-cue task and a matching task. We found that FI observers responded faster and had stronger modulation in eye vergence in both tasks than FD subjects. The results may suggest that eye vergence modulation may relate to the trade-off between the size of spatial region covered by attention and the processing efficiency of sensory information. Alternatively, vergence modulation may have a role in the switch in cortical state to prepare the visual system for new incoming sensory information. In conclusion, vergence eye movements may be added to the growing list of functions of fixational eye movements in visual perception. However, further studies are needed to elucidate its role. PMID:24069140

  14. Priorities and trends in the study of proteins in eye research, 1924–2014

    PubMed Central

    Semba, Richard D.; Lam, Maggie; Sun, Kai; Zhang, Pingbo; Schaumberg, Debra A.; Ferrucci, Luigi; Ping, Peipei; Van Eyk, Jennifer E.

    2015-01-01

    Purpose To identify the proteins that are relevant to eye research and develop assays for the study of a set of these proteins. Experimental Design We conducted a bibliometric analysis by merging gene lists for human and mouse from the National Center for Biotechnology Information FTP site and combining them with PubMed references that were retrieved with the search terms “eye”[MeSH Terms] OR “eye”[All Fields] OR “eyes”[All Fields]. Results For human and mouse eye studies, respectively, the total number of publications was 13,525 and 23,895, and the total number of proteins was 4,050 and 4,717. For proteins in human and mouse eye studies, respectively, 88.7% and 81.7% had five or fewer citations. The top fifty most intensively studied proteins for human and mouse eye studies were generally in the areas of photoreceptors and phototransduction, inflammation and angiogenesis, neurodevelopment, lens transparency, and cell cycle and cellular processes. We proposed selected reaction monitoring assays that were developed in silico for the top fifty most intensively studied proteins in human and mouse eye research. Conclusions and clinical relevance We conclude that scientists engaged in eye research tend to focus on the same proteins. Newer resources and tools in proteomics can expand the investigations to lesser-known proteins of the eye. PMID:26123431

  15. Arthropod eye-inspired digital camera with unique imaging characteristics

    NASA Astrophysics Data System (ADS)

    Xiao, Jianliang; Song, Young Min; Xie, Yizhu; Malyarchuk, Viktor; Jung, Inhwa; Choi, Ki-Joong; Liu, Zhuangjian; Park, Hyunsung; Lu, Chaofeng; Kim, Rak-Hwan; Li, Rui; Crozier, Kenneth B.; Huang, Yonggang; Rogers, John A.

    2014-06-01

    In nature, arthropods have a remarkably sophisticated class of imaging systems, with a hemispherical geometry, a wideangle field of view, low aberrations, high acuity to motion and an infinite depth of field. There are great interests in building systems with similar geometries and properties due to numerous potential applications. However, the established semiconductor sensor technologies and optics are essentially planar, which experience great challenges in building such systems with hemispherical, compound apposition layouts. With the recent advancement of stretchable optoelectronics, we have successfully developed strategies to build a fully functional artificial apposition compound eye camera by combining optics, materials and mechanics principles. The strategies start with fabricating stretchable arrays of thin silicon photodetectors and elastomeric optical elements in planar geometries, which are then precisely aligned and integrated, and elastically transformed to hemispherical shapes. This imaging device demonstrates nearly full hemispherical shape (about 160 degrees), with densely packed artificial ommatidia. The number of ommatidia (180) is comparable to those of the eyes of fire ants and bark beetles. We have illustrated key features of operation of compound eyes through experimental imaging results and quantitative ray-tracing-based simulations. The general strategies shown in this development could be applicable to other compound eye devices, such as those inspired by moths and lacewings (refracting superposition eyes), lobster and shrimp (reflecting superposition eyes), and houseflies (neural superposition eyes).

  16. Insights into autofluorescence patterns in Stargardt macular dystrophy using ultra-wide-field imaging.

    PubMed

    Kumar, Vinod

    2017-10-01

    To characterize autofluorescence (AF) patterns occurring in Stargardt macular dystrophy (STGD1) using ultra-wide-field (UWF) imaging. This paper is a cross-sectional observational study of 22 eyes of 11 patients (mean age 23.44 years) with Stargardt disease-fundus flavimaculatus who presented with decrease of vision at a tertiary eye care center. UWF short-wave AF images were obtained from all the patients using an Optos TX200 instrument. The main outcome measures were to assess patterns of AF changes seen on UWF AF imaging. All eyes showed a central area of hypoautofluorescence at the macula along with retinal flecks extending centrifugally as well as to the nasal side of the optic disc. Peripapillary sparing was seen in 100% of the eyes. Flecks were seen to be hypoautofluorescent in the center and hyperautofluorescent in the periphery in 77.8% eyes and were only hyperfluorescent in 27.2%. A background-increased fluorescence was visible in 100% of eyes, the outer boundary of which was marked by distribution of flecks in 81.9% eyes. A characteristic inferonasal vertical line was seen separating the nasal hypoautofluorescent area from the temporal hyperautofluorescent area in all the eyes. UWF AF changes in STGD1 are not limited to the posterior pole and may extend more peripherally. UWF imaging is a useful tool for the assessment of patients with Stargardt macular dystrophy.

  17. Relationship between saccadic eye movements and formation of the Krukenberg's spindle-a CFD study.

    PubMed

    Boushehrian, Hamidreza Hajiani; Abouali, Omid; Jafarpur, Khosrow; Ghaffarieh, Alireza; Ahmadi, Goodarz

    2017-09-01

    In this research, a series of numerical simulations for evaluating the effects of saccadic eye movement on the aqueous humour (AH) flow field and movement of pigment particles in the anterior chamber (AC) was performed. To predict the flow field of AH in the AC, the unsteady forms of continuity, momentum balance and conservation of energy equations were solved using the dynamic mesh technique for simulating the saccadic motions. Different orientations of the human eye including horizontal, vertical and angles of 10° and 20° were considered. The Lagrangian particle trajectory analysis approach was used to find the trajectories of pigment particles in the eye. Particular attention was given to the relation between the saccadic eye movement and potential formation of Krukenberg's spindle in the eye. The simulation results revealed that the natural convection flow was an effective mechanism for transferring pigment particles from the iris to near the cornea. In addition, the saccadic eye movement was the dominant mechanism for deposition of pigment particles on the cornea, which could lead to the formation of Krukenberg's spindle. The effect of amplitude of saccade motion angle in addition to the orientation of the eye on the formation of Krukenberg's spindle was investigated. © The authors 2016. Published by Oxford University Press on behalf of the Institute of Mathematics and its Applications. All rights reserved.

  18. Peripheral refraction with eye and head rotation with contact lenses.

    PubMed

    Lopes-Ferreira, Daniela P; Neves, Helena I F; Faria-Ribeiro, Miguel; Queirós, António; Fernandes, Paulo R B; González-Méijome, José M

    2015-04-01

    To evaluate the impact of eye and head rotation in the measurement of peripheral refraction with an open-field autorefractometer in myopic eyes wearing two different center-distance designs of multifocal contact lenses (MFCLs). Nineteen right eyes from 19 myopic patients (average central M ± SD = -2.67 ± 1.66 D) aged 20-27 years (mean ± SD = 23.2 ± 3.3 years) were evaluated using a Grand-Seiko autorefractometer. Patients were fitted with one multifocal aspheric center-distance contact lens (Biofinity Multifocal D(®)) and with one multi-concentric MFCL (Acuvue Oasys for Presbyopia). Axial and peripheral refraction were evaluated by eye rotation and by head rotation under naked eye condition and with each MFCL fitted randomly and in independent sessions. For the naked eye, refractive pattern (M, J0 and J45) across the central 60° of the horizontal visual field values did not show significant changes measured by rotating the eye or rotating the head (p > 0.05). Similar results were obtained wearing the Biofinity D, for both testing methods, no obtaining significant differences to M, J0 and J45 values (p > 0.05). For Acuvue Oasys for presbyopia, also no differences were found when comparing measurements obtained by eye and head rotation (p > 0.05). Multivariate analysis did not showed a significant interaction between testing method and lens type neither with measuring locations (MANOVA, p > 0.05). There were significant differences in M and J0 values between naked eyes and each MFCL. Measurements of peripheral refraction by rotating the eye or rotating the head in myopic patients wearing dominant design or multi-concentric multifocal silicone hydrogel contact lens are comparable. Copyright © 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  19. Hemiretinal form deprivation: evidence for local control of eye growth and refractive development in infant monkeys.

    PubMed

    Smith, Earl L; Huang, Juan; Hung, Li-Fang; Blasdel, Terry L; Humbird, Tammy L; Bockhorst, Kurt H

    2009-11-01

    To determine whether refractive development in primates is mediated by local retinal mechanisms, the authors examined the effects of hemiretinal form deprivation on ocular growth and the pattern of peripheral refractions in rhesus monkeys. Beginning at approximately 3 weeks of age, nine infant monkeys were reared wearing monocular diffuser lenses that eliminated form vision in the nasal field (nasal field diffuser [NFD]). Control data were obtained from the nontreated fellow eyes, 24 normal monkeys, and 19 monkeys treated with full-field diffusers. Refractive development was assessed by retinoscopy performed along the pupillary axis and at eccentricities of 15 degrees, 30 degrees, and 45 degrees. Central axial dimensions and eye shape were assessed by A-scan ultrasonography and magnetic resonance imaging, respectively. Hemiretinal form deprivation altered refractive development in a regionally selective manner, typically producing myopia in the treated hemifields. In particular, six of the NFD monkeys exhibited substantial amounts (-1.81 to -9.00 D) of relative myopia in the nasal field that were most obvious at the 15 degrees and 30 degrees nasal field eccentricities. The other three NFD monkeys exhibited small amounts of relative hyperopia in the treated field. The alterations in peripheral refraction were associated with local, region-specific alterations in vitreous chamber depth in the treated hemiretina. The effects of form deprivation on refractive development and eye growth in primates are mediated by mechanisms, presumably retinal, that integrate visual signals in a spatially restricted manner and exert their influence locally.

  20. Structural-functional relationships between eye orbital imaging biomarkers and clinical visual assessments

    NASA Astrophysics Data System (ADS)

    Yao, Xiuya; Chaganti, Shikha; Nabar, Kunal P.; Nelson, Katrina; Plassard, Andrew; Harrigan, Rob L.; Mawn, Louise A.; Landman, Bennett A.

    2017-02-01

    Eye diseases and visual impairment affect millions of Americans and induce billions of dollars in annual economic burdens. Expounding upon existing knowledge of eye diseases could lead to improved treatment and disease prevention. This research investigated the relationship between structural metrics of the eye orbit and visual function measurements in a cohort of 470 patients from a retrospective study of ophthalmology records for patients (with thyroid eye disease, orbital inflammation, optic nerve edema, glaucoma, intrinsic optic nerve disease), clinical imaging, and visual function assessments. Orbital magnetic resonance imaging (MRI) and computed tomography (CT) images were retrieved and labeled in 3D using multi-atlas label fusion. Based on the 3D structures, both traditional radiology measures (e.g., Barrett index, volumetric crowding index, optic nerve length) and novel volumetric metrics were computed. Using stepwise regression, the associations between structural metrics and visual field scores (visual acuity, functional acuity, visual field, functional field, and functional vision) were assessed. Across all models, the explained variance was reasonable (R2 0.1-0.2) but highly significant (p < 0.001). Instead of analyzing a specific pathology, this study aimed to analyze data across a variety of pathologies. This approach yielded a general model for the connection between orbital structural imaging biomarkers and visual function.

  1. Lung function parameters of healthy Sri Lankan Tamil young adults.

    PubMed

    Balasubramaniam, M; Sivapalan, K; Thuvarathipan, R

    2014-06-01

    To establish reference norms of lung function parameters for healthy Sri Lankan Tamil young adults. Cross sectional study of Tamil students at the Faculty of Medicine, Jaffna. Healthy non smoking students of Sri Lankan Tamil ethnic group were enrolled. Age, height, weight, BMI and spirometric measurements (Micro Quark) were recorded in 267 participants (137 females and 130 males). Height was significantly correlated with (p<0.05) all the lung function parameters except FEV1%, PEFR and MEF75 in males. Prediction equations were derived by regression analysis based on the height as an independent variable. Predicted lung function values for a particular age and height were lower than values predicted for Pakistanis, Kelatanese Malaysians and eastern Indians. The values were comparable to south Indians in Madras. Our FVC values of males and VC of females were closer to Sri Lankan Sinhalese. FEV1 and FEF25-75 in males were slightly higher and FVC, FEV1 and FEF25-75 in females were slightly lower in Tamils. When mean values were compared, these parameters were significantly higher in Tamil males (p<0.001) and significantly lower in Tamil females (p<0.001). These values will be useful in interpreting lung function parameters of the particular age group as there are no published norms for Sri Lankan Tamils. However, our study sample was confined to medical students of 20-28 years which may explain the differences with Sinhalese.

  2. Pulmonary functions in air conditioner users.

    PubMed

    Khaliq, Farah; Sharma, Sameer; Tandon, O P

    2006-01-01

    Air conditioning may affect human health since it has profound effect on our environment, than just lowering temperature. The present study was planned to assess the effect of air conditioners (AC) on pulmonary functions in young healthy non-smoker males. The study group comprised of ten subjects who were using AC's in their cars for at least 1 hr daily since last 6 months. While ten subjects who did not use AC at all served as controls. The pulmonary functions were assessed using PK Morgan 232 spirometer in a closed room. The peak expiratory flow rate (PEFR) and Forced expiratory flow between 25-75% of vital capacity (FEF25-75) were significantly reduced in subjects using car AC's. Inspiratory flow rates also showed a trend towards decline in AC users but could not reach the level of significance. The lung volumes and capacities were not significantly different in the two groups except for forced expiratory volume in 0.5 sec (FEV 0.5 sec), which also decreased in AC users. The airway resistance and lung compliance did not show significant change. In the presence of normal FEV1, reduced FEF25-75% which is the flow rate over the middle half of vital capacity, is an evidence of mild airflow limitation. The result is suggestive of predisposition of AC users towards respiratory disorders in form of mild airflow restriction.

  3. Respiratory function in wind instrument players.

    PubMed

    Zuskin, Eugenija; Mustajbegovic, Jadranka; Schachter, E N; Kern, Josipa; Vitale, Ksenija; Pucarin-Cvetkovic, Jasna; Chiarelli, A; Milosevic, M; Jelinic, Jagoda Doko

    2009-01-01

    The playing of wind instruments has been associated with changes in respiratory function. To investigate the effect of playing wind instruments on lung function and respiratory symptoms. The present study included 99 wind instrument players and a group of 41 string instrument players as a control from 3 major orchestras in Zagreb, Croatia. Data on chronic respiratory symptoms were recorded in all studied subjects. Lung function was measured in wind instrument players by recording maximum expiratory flow-volume curves. Wind instrument players demonstrated significantly higher prevalences of sinusitis, nasal catarrh and hoarseness compared to control musicians. One wind instrument player developed asthma associated with his work. Odds ratios for wind instrument players were significant for chronic cough, chronic phlegm and chronic bronchitis by smoking habit (p<0.05 or p<0.01) but not for length of employment. Ventilatory capacity data indicate that wind instrument players had significantly greater FEV1 (smokers and nonsmokers) as well as FEF50 (nonsmokers) (p<0.05) compared to predicted values. Regression analysis of pulmonary function tests in wind instrument players demonstrate a significant link between FEV1 and FEF50 and length of employment. Those wind instrument players with longer employment had the greatest increases in lung function. Our data suggest that musicians playing wind instruments may be susceptible to chronic upper airway symptoms. Interestingly wind instrument playing may be associated with higher than expected lung function parameters.

  4. Population Intervention Models to Estimate Ambient NO2 Health Effects in Children with Asthma

    PubMed Central

    Snowden, Jonathan M.; Mortimer, Kathleen M.; Dufour, Mi-Suk Kang; Tager, Ira B.

    2015-01-01

    Health effects of ambient air pollution are most frequently expressed in individual studies as responses to a standardized unit of air pollution changes (e.g., an interquartile interval), which is thought to enable comparison of findings across studies. However, this approach does not necessarily convey health effects in terms of a real-world air pollution scenario. In the present study, we employ population intervention modeling to estimate the effect of an air pollution intervention that makes explicit reference to the observed exposure data and is identifiable in those data. We calculate the association between ambient summertime NO2 and forced expiratory flow between 25% and 75% of forced vital capacity (FEF25–75) in a cohort of children with asthma in Fresno, California. We scale the effect size to reflect NO2 abatement on a majority of summer days. The effect estimates were small, imprecise, and consistently indicated improved pulmonary function with decreased NO2. The effects ranged from −0.8% of mean FEF25–75 (95% Confidence Interval: −3.4 , 1.7) to −3.3% (95% CI: −7.5, 0.9). We conclude by discussing the nature and feasibility of the exposure change analyzed here given the observed air pollution profile, and we propose additional applications of the population intervention model in environmental epidemiology. PMID:25182844

  5. Air pollution and fuel vapour induced changes in lung functions: are fuel handlers safe?

    PubMed

    Chawla, Anuj; Lavania, A K

    2008-01-01

    Automobile exhaust derived air pollutants have become a major health hazard. Coupled with the inhalation of fuel vapour, as occurs in petrol station workers, this may lead to significant impairment of lung function. Spirometric lung functions were studied in 58 petrol station workers to examine this possibility. The forced vital capacity (FVC), forced expiratory volume in 1 second (FEV1), forced expiratory flow 25%-75% (FEF25-75) and peak expiratory flow (PEF) were recorded and analysed separately for smokers and non-smokers. The workers were divided into 5 groups for analysis of data based on the number of years of work in the petrol pumps. Outdoor air analysis was also carried out. The FVC, FEV1 and PEF declined significantly with increasing years of work in petrol stations in both smokers and non-smokers. Smoking as an independent variable was found to affect the FEV1 significantly but not FVC or PEF. The FEF25-75 was found to be the most affected spirometric value with a significant reduction with increasing years of work. Smoking as such did not affect it. Oxides of nitrogen (NOx), suspended particulate matter (SPM) and particulate matter less than 10 microns (PM10) in outdoor air were higher than the national ambient air quality standards. Exposure to automobile exhaust and fuel vapour impairs lung function in a time-dependent manner. Cigarette smoking appears to accelerate the decline.

  6. Long-Term Experimental Acidification Drives Watershed Scale Shift in Dissolved Organic Matter Composition and Flux.

    PubMed

    SanClements, Michael D; Fernandez, Ivan J; Lee, Robert H; Roberti, Joshua A; Adams, Mary Beth; Rue, Garret A; McKnight, Diane M

    2018-03-06

    Over the last several decades dissolved organic carbon concentrations (DOC) in surface waters have increased throughout much of the northern hemisphere. Several hypotheses have been proposed regarding the drivers of this phenomenon including decreased sulfur (S) deposition working via an acidity- change mechanism. Using fluorescence spectroscopy and data from two long-term (24+ years at completion of this study) whole watershed acidification experiments, that is, the Bear Brook Watershed in Maine (BBWM) and Fernow Experimental Forest in West Virginia (FEF) allowed us to control for factors other than the acidity-change mechanism (e.g., differing vegetation, shifting climate), resulting in the first study we are aware of where the acidity change mechanism could be experimentally isolated at the whole ecosystem and decadal scales as the driver of shifts in DOM dynamics. The multidecadal record of stream chemistry at BBWM demonstrates a significantly lower DOC concentration in the treated compared to the reference watershed. Additionally, at both BBWM and FEF we found significant and sustained differences in stream fluorescence index (FI) between the treated and reference watersheds, with the reference watersheds demonstrating a stronger terrestrial DOM signature. These data, coupled with evidence of pH shifts in upper soil horizons support the hypotheses that declines in S deposition are driving changes in the solubility of soil organic matter and increased flux of terrestrial DOC to water bodies.

  7. Ginseng improves pulmonary functions and exercise capacity in patients with COPD.

    PubMed

    Gross, D; Shenkman, Z; Bleiberg, B; Dayan, M; Gittelson, M; Efrat, R

    2002-01-01

    Ginseng is a root that has been used to treat patients with various illnesses for the last 2000 years. The purpose of this study was to evaluate the effects of Ginseng extract (G115) on Pulmonary Function Tests (PFTs), Maximum Voluntary Ventilation (MVV), Maximum Inspiratory Pressure (MIP) and Maximal Oxygen Consumption (VO2max) in patients with moderately-severe Chronic Obstructive Pulmonary Disease (COPD). Ninety-two adults were randomly divided into the experimental (n = 49, G115 100 mg bid for three months) and placebo-control (n = 43) groups. PFTs, MVV and MIP were studied before treatment and every two weeks for the 3-month-study period. Exercise test and VO2max measurements were performed before the beginning and after six weeks and three months. P lower than 0.05 was considered significant. Baseline demographics and pulmonary parameters were similar between the groups. In the experimental, but not in the control group, all parameters significantly increased above baseline and compared with the placebo group. Maximum increase, compared with baseline was FVC-32.5%, FEV1.0-27.0%, PEF-27.5%, FEF50-45.4%, FEF75-56.9%, MVV-40.4%, MIP-47.0% and VO2max-37.5%. No side effects were observed. G115 100 mg bid for three months, but not placebo, improved PFTs, MVV, MIP and VO2 max in patients with moderately-severe COPD with no side effects.

  8. Lung function among 9- to 10-year-old Tibetan and Han Chinese schoolchildren living at different altitudes in Tibet.

    PubMed

    Yangzong; Berntsen, Sveinung; Bjertness, Espen; Stigum, Hein; Gonggalanzi; Bianba; Nafstad, Per

    2013-03-01

    Tibetans have lived at high altitude longer than any other high-altitude population. Still little is known about their lung function and especially among children. This study compared lung function values of forced vital capacity (FVC), forced expiratory volume in one second (FEV1), and forced expiratory flow at 50% of FVC (FEF50) in children living at various altitudes in Tibet and with different ancestries. A cross-sectional study of lung function was performed among 9-10-year-old native Tibetan and Han Chinese children living at 3700 meters above sea level, and among native Tibetan children living at 4300 meters above sea level. The adjusted FVC and FEV1 were significantly higher in Tibetan children living at 4300 m above sea level as compared to Tibetans living at 3700 m. Tibetans living at 3700 m had higher FVC and FEV1 than Han Chinese living at the same altitude. All Tibetan children had on average higher FEF50 than Han Chinese. Tibetan children living at an altitude of 4300 m had relatively higher lung function than those living at 3700 m, and there were differences in lung function between Tibetans and Han Chinese who live at the same altitude. It seems likely that genetic factors involved in long-term adaptation to high altitude and cultural attributes could have contributed to the study findings.

  9. Roles of ADAM13-regulated Wnt activity in early Xenopus eye development

    PubMed Central

    Wei, Shuo; Xu, Guofeng; Bridges, Lance C.; Williams, Phoebe; Nakayama, Takuya; Shah, Anoop; Grainger, Robert M.; White, Judith M.; DeSimone, Douglas W.

    2012-01-01

    Pericellular proteolysis by ADAM family metalloproteinases has been widely implicated in cell signaling and development. We recently found that Xenopus ADAM13, an ADAM metalloproteinase, is required for activation of canonical Wnt signaling during cranial neural crest (CNC) induction by regulating a novel crosstalk between Wnt and ephrin B (EfnB) signaling pathways (Wei et al., 2010b). In the present study we show that the metalloproteinase activity of ADAM13 also plays important roles in eye development in X. tropicalis. Knockdown of ADAM13 results in reduced expression of eye field markers pax6 and rx1, as well as that of the pan-neural marker sox2. Activation of canonical Wnt signaling or inhibition of forward EfnB signaling rescues the eye defects caused by loss of ADAM13, suggesting that ADAM13 functions through regulation of the EfnB-Wnt pathway interaction. Downstream of Wnt, the head inducer Cerberus was identified as an effector that mediates ADAM13 function in early eye field formation. Furthermore, ectopic expression of the Wnt target gene snail2 restores cerberus expression and rescues the eye defects caused by ADAM13 knockdown. Together these data suggest an important role of ADAM13-regulated Wnt activity in eye development in Xenopus. PMID:22227340

  10. Peripapillary schisis in open-angle glaucoma.

    PubMed

    Dhingra, N; Manoharan, R; Gill, S; Nagar, M

    2017-03-01

    PurposeTo report clinical features, topographic findings and outcome of 10 eyes with peripapillary schisis in open-angle glaucoma.Patients and methodsA retrospective review of patients with open-angle glaucoma who were noted to have peripapillary schisis on optical coherence tomography (OCT) were included. Serial peripapillary and macula infrared and OCT images, visual acuity, visual fields, and schisis appearance were reviewed.ResultsTen eyes of nine patients with open-angle glaucoma were detected to have the presence of peripapillary schisis. Nerve fibre layer schisis was detected in all eyes and one eye had an associated macular schisis. None of the eyes had an acquired pit of the optic nerve or pathological myopia. The mean intraocular pressures at detection was 18.3±4.3 mm Hg and the schisis resolved in four eyes after a mean follow-up of 21.2±8.8 months. Visual field worsening was noted in 4 of the 10 eyes and the resolution of schisis resulted in significant reduction in the retinal nerve fibre layer (RNFL) thickness.ConclusionsPeripapillary schisis detected during the normal course of open-angle glaucoma can resolve spontaneously and rarely involves the macula. Its resolution leads to reduction in RNFL thickness; therefore, caution is advised while interpreting serial scans.

  11. Catadioptric planar compound eye with large field of view.

    PubMed

    Deng, Huaxia; Gao, Xicheng; Ma, Mengchao; Li, Yunyang; Li, Hang; Zhang, Jin; Zhong, Xiang

    2018-05-14

    The planar compound eye has the advantages of simple structure and no requirement for complex relay optical elements, but the field of view (FOV) is very difficult to expand. Overcoming the limitation of FOV, especially with simple structures, is a great challenge for the development of planar compound eyes. Different from the existing designs that only considering refraction, this article proposes a catadioptric planar compound eye based on the reflection and refraction to expand the FOV. In the proposed design, the incident light from a large angle is reflected into the lenslet array by two rotationally symmetric mirrors whose surface equations are optimized by mathematical and optical softwares. The FOV of the proposed catadioptric planar compound eye theoretically can reach 96.6°, which is much wider than the opening record of 70°. Moreover, no distortion of the imaging system can be obtained theoretically in this design. Simulation results show a linearity of better than 99% for the most of the incident angles. The verification experiments show that the FOV of the proposed device can reach 90.7° while the FOV of the corresponding planar compound eye without mirrors is 41.6°. The proposed catadioptric planar compound eye has the great potential in monitoring, detection and virtual reality since the FOV has been widen significantly.

  12. Computational modelling of temperature rises in the eye in the near field of radiofrequency sources at 380, 900 and 1800 MHz

    NASA Astrophysics Data System (ADS)

    Wainwright, P. R.

    2007-07-01

    This paper reports calculations of the temperature rises induced in the eye and lens by near-field exposure to radiation from communication handsets, using the finite difference time domain method and classical bioheat equation. Various models are compared, including the analytic solution for a sphere, a finite element model of an isolated eye and a modern model of the whole head. The role of the blood supply to the choroid in moderating temperature is discussed. Three different frequencies are considered, namely 380 MHz (used by TETRA), and 900 and 1800 MHz (used by GSM mobile phones). At 380 MHz, monopole and helical antennas are compared. An 'equivalent blood flow' is derived for the choroid in order to facilitate comparison of the whole head and isolated eye models. In the whole head model, the heating of the lens receives a significant contribution from energy absorbed outside the eye. The temperature rise in the lens is compared to the ICNIRP-recommended average specific energy absorption rate (SAR) and the SAR averaged over the eye alone. The temperature rise may reach 1.4 °C at the ICNIRP occupational exposure limit if an antenna is placed less than 24 mm from the eye and the exposure is sufficiently prolonged.

  13. How aquatic water-beetle larvae with small chambered eyes overcome challenges of hunting under water.

    PubMed

    Stowasser, Annette; Buschbeck, Elke K

    2014-11-01

    A particularly unusual visual system exists in the visually guided aquatic predator, the Sunburst Diving Beetle, Thermonectus marmoratus (Coleoptera: Dytiscidae). The question arises: how does this peculiar visual system function? A series of experiments suggests that their principal eyes (E1 and E2) are highly specialized for hunting. These eyes are tubular and have relatively long focal lengths leading to high image magnification. Their retinae are linear, and are divided into distinct green-sensitive distal and UV and polarization-sensitive proximal portions. Each distal retina, moreover, has many tiers of photoreceptors with rhabdomeres the long axis of which are peculiarly oriented perpendicular to the light path. Based on detailed optical investigations, the lenses of these eyes are bifocal and project focused images onto specific retinal tiers. Behavioral experiments suggest that these larvae approach prey within their eyes' near-fields, and that they can correctly gauge prey distances even when conventional distance-vision mechanisms are unavailable. In the near-field of these eyes object distance determines which of the many retinal layers receive the best-focused images. This retinal organization could facilitate an unusual distance-vision mechanism. We here summarize past findings and discuss how these eyes allow Thermonectus larvae to be such successful predators.

  14. Computational modelling of temperature rises in the eye in the near field of radiofrequency sources at 380, 900 and 1800 MHz.

    PubMed

    Wainwright, P R

    2007-06-21

    This paper reports calculations of the temperature rises induced in the eye and lens by near-field exposure to radiation from communication handsets, using the finite difference time domain method and classical bioheat equation. Various models are compared, including the analytic solution for a sphere, a finite element model of an isolated eye and a modern model of the whole head. The role of the blood supply to the choroid in moderating temperature is discussed. Three different frequencies are considered, namely 380 MHz (used by TETRA), and 900 and 1800 MHz (used by GSM mobile phones). At 380 MHz, monopole and helical antennas are compared. An 'equivalent blood flow' is derived for the choroid in order to facilitate comparison of the whole head and isolated eye models. In the whole head model, the heating of the lens receives a significant contribution from energy absorbed outside the eye. The temperature rise in the lens is compared to the ICNIRP-recommended average specific energy absorption rate (SAR) and the SAR averaged over the eye alone. The temperature rise may reach 1.4 degrees C at the ICNIRP occupational exposure limit if an antenna is placed less than 24 mm from the eye and the exposure is sufficiently prolonged.

  15. Adalimumab and Non-Arteritic Anterior Ischaemic Optic Neuropathy: A Case Report.

    PubMed

    Kinard, Krista; Walsh, Jessica A; Penmetsa, Gopi K; Warner, Judith E A

    2014-01-01

    Sequential anterior ischaemic optic neuropathy was observed in a patient treated with a tumour necrosis factor α (TNF) inhibitor, adalimumab, for ankylosing spondylitis. He developed decreased visual acuity in the right eye after 17 months of treatment. Findings showed right optic disc oedema with haemorrhages and visual field defect. Adalimumab was discontinued and vision stabilised. After restarting adalimumab, he developed optic neuropathy in the left eye. Findings showed optic disc oedema, with haemorrhages and visual field changes in the left eye. Adalimumab may be associated with optic neuropathy; providers prescribing TNF inhibitors should be aware of optic neuropathy as a potential complication.

  16. Contralateral eye comparison on changes in visual field following laser in situ keratomileusis vs photorefractive keratectomy for myopia: a randomized clinical trial.

    PubMed

    Mostafaei, A; Sedgipour, M R; Sadeghi-Bazargani, H

    2009-12-01

    Study purpose was to compare the changes of Visual Field (VF) during laser in situ Keratomileusis (LASIK) VS photorefractive keratectomy (PRK). This randomized, double blind, study involved 54 eyes of 27 Myopia patients who underwent LASIK or PRK procedures for contralateral eyes in each patient. Using Humphrey 30-2 SITA standard, the Mean Defect (MD) and Pattern Standard Deviation (PSD) were evaluated preoperatively and three months after surgery. At the same examination optical zone size, papillary and corneal diameters were also evaluated. There was no clinically significant difference in PSD and MD measurements between treated eyes with LASIK or PRK in any zone pre and postoperatively. VF may not be affected by corneal changes induced by LASIK or PRK three months after surgery.

  17. Lateralization of magnetic compass orientation in a migratory bird

    NASA Astrophysics Data System (ADS)

    Wiltschko, Wolfgang; Traudt, Joachim; Güntürkün, Onur; Prior, Helmut; Wiltschko, Roswitha

    2002-10-01

    Lateralization of brain functions, once believed to be a human characteristic, has now been found to be widespread among vertebrates. In birds, asymmetries of visual functions are well studied, with each hemisphere being specialized for different tasks. Here we report lateralized functions of the birds' visual system associated with magnetoperception, resulting in an extreme asymmetry of sensing the direction of the magnetic field. We found that captive migrants tested in cages with the magnetic field as the only available orientation cue were well oriented in their appropriate migratory direction when using their right eye only, but failed to show a significant directional preference when using their left eye. This implies that magnetoreception for compass orientation, assumed to take place in the eyes alongside the visual processes, is strongly lateralized, with a marked dominance of the right eye/left brain hemisphere.

  18. Improved high-resolution ultrasonic imaging of the eye.

    PubMed

    Silverman, Ronald H; Ketterling, Jeffrey A; Mamou, Jonathan; Coleman, D Jackson

    2008-01-01

    Currently, virtually all clinical diagnostic ultrasound systems used in ophthalmology are based on fixed-focus, single-element transducers. High-frequency (> or = 20-MHz) transducers introduced to ophthalmology during the last decade have led to improved resolution and diagnostic capabilities for assessment of the anterior segment and the retina. However, single-element transducers are restricted to a small depth of field, limiting their capacity to image the eye as a whole. We fabricated a 20-MHz annular array probe prototype consisting of 5 concentric transducer elements and scanned an ex vivo human eye. Synthetically focused images of the bank eye showed improved depth of field and sensitivity, allowing simultaneous display of the anterior and posterior segments and the full lens contour. This capability may be useful in assessment of vitreoretinal pathologies and investigation of the accommodative mechanism.

  19. Relationship among visual field, blood flow, and neural structure measurements in glaucoma.

    PubMed

    Hwang, John C; Konduru, Ranjith; Zhang, Xinbo; Tan, Ou; Francis, Brian A; Varma, Rohit; Sehi, Mitra; Greenfield, David S; Sadda, Srinivas R; Huang, David

    2012-05-17

    To determine the relationship among visual field, neural structural, and blood flow measurements in glaucoma. Case-control study. Forty-seven eyes of 42 patients with perimetric glaucoma were age-matched with 27 normal eyes of 27 patients. All patients underwent Doppler Fourier-domain optical coherence tomography to measure retinal blood flow and standard glaucoma evaluation with visual field testing and quantitative structural imaging. Linear regression analysis was performed to analyze the relationship among visual field, blood flow, and structure, after all variables were converted to logarithmic decibel scale. Retinal blood flow was reduced in glaucoma eyes compared to normal eyes (P < 0.001). Visual field loss was correlated with both reduced retinal blood flow and structural loss of rim area and retinal nerve fiber layer (RNFL). There was no correlation or paradoxical correlation between blood flow and structure. Multivariate regression analysis revealed that reduced blood flow and structural loss are independent predictors of visual field loss. Each dB decrease in blood flow was associated with at least 1.62 dB loss in mean deviation (P ≤ 0.001), whereas each dB decrease in rim area and RNFL was associated with 1.15 dB and 2.56 dB loss in mean deviation, respectively (P ≤ 0.03). There is a close link between reduced retinal blood flow and visual field loss in glaucoma that is largely independent of structural loss. Further studies are needed to elucidate the causes of the vascular dysfunction and potential avenues for therapeutic intervention. Blood flow measurement may be useful as an independent assessment of glaucoma severity.

  20. Evaluating Glaucomatous Retinal Nerve Fiber Damage by GDx VCC Polarimetry in Taiwan Chinese Population

    PubMed Central

    Chen, Hsin-Yi; Huang, Mei-Ling; Huang, Wei-Cheng

    2010-01-01

    Purpose To study the capability of scanning laser polarimetry with variable corneal compensation (GDx VCC) to detect differences in retinal nerve fiber layer thickness between normal and glaucomatous eyes in a Taiwan Chinese population. Methods This study included 44 normal eyes and 107 glaucomatous eyes. The glaucomatous eyes were divided into three subgroups on the basis of its visual field defects (early, moderate, severe). Each subject underwent a GDx-VCC exam and visual field testing. The area under the receiver-operating characteristic curve (AROC) of each relevant parameter was used to differentiate normal from each glaucoma subgroup, respectively. The correlation between visual field index and each parameter was evaluated for the eyes in the glaucoma group. Results For normal vs. early glaucoma, the parameter with the best AROC was Nerve fiber indicator (NFI) (0.942). For normal vs. moderate glaucoma, the parameter showing the best AROC was NFI (0.985). For normal vs. severe glaucoma, the parameter that had the best AROC was NFI (1.000). For early vs. moderate glaucoma, the parameter with the best AROC was NFI (0.732). For moderate vs. severe, the parameter showing the best AROC was temporal-superior-nasal-inferior-temporal average (0.652). For early vs. severe, the parameter with the best AROC was NFI (0.852). Conclusions GDx-VCC-measured parameters may serve as a useful tool to distinguish normal from glaucomatous eyes; in particular, NFI turned out to be the best discriminating parameter.

  1. Morphological Features and Important Parameters of Large Optic Discs for Diagnosing Glaucoma

    PubMed Central

    Okimoto, Satoshi; Yamashita, Keiko; Shibata, Tetsuo; Kiuchi, Yoshiaki

    2015-01-01

    Purpose To compare the optic disc parameters of glaucomatous eyes to those of non-glaucomatous eyes with large discs. Methods We studied 225 consecutive eyes with large optic discs (>2.82 mm2): 91 eyes with glaucoma and 134 eyes without glaucoma. An eye was diagnosed with glaucoma when visual field defects were detected by the Humphrey Field Analyzer. All of the Heidelberg Retina Tomograph II (HRT II) parameters were compared between the non-glaucomatous and glaucomatous eyes. A logistic regression analysis of the HRT II parameters was used to establish a new formula for diagnosing glaucoma, and the sensitivity and specificity of the Moorfields Regression Analysis (MRA) was compared to the findings made by our analyses. Results The mean disc area was 3.44±0.50 mm2 in the non-glaucomatous group and 3.40±0.52 mm2 in the glaucoma group. The cup area, cup volume, cup-to-disc area ratio, linear cup/disc ratio, mean cup depth, and the maximum cup depth were significantly larger in glaucomatous eyes than in the non-glaucomatous eyes. The rim area, rim volume, cup shape measurement, mean retinal nerve fiber layer (RNFL) thickness, and RFNL cross-sectional area were significantly smaller in glaucomatous eyes than in non-glaucomatous eyes. The cup-to-disc area ratio, the height variation contour (HVC), and the RNFL cross-sectional area were important parameters for diagnosing the early stage glaucoma, and the cup-to-disc area ratio and cup volume were useful for diagnosing advanced stage glaucoma in eyes with a large optic disc. The new formula had higher sensitivity and specificity for diagnosing glaucoma than MRA. Conclusions The cup-to-disc area ratio, HVC, RNFL cross-sectional area, and cup volume were important parameters for diagnosing glaucoma in eyes with a large optic disc. The important disc parameters to diagnose glaucoma depend on the stage of glaucoma in patients with large discs. PMID:25798580

  2. Rate of progression of total, upper, and lower visual field defects in patients with open-angle glaucoma and high myopia.

    PubMed

    Yoshino, Takaiko; Fukuchi, Takeo; Togano, Tetsuya; Sakaue, Yuta; Seki, Masaaki; Tanaka, Takayuki; Ueda, Jun

    2016-03-01

    We evaluated the rate of progression of total, upper, and lower visual field defects in patients with treated primary open-angle glaucoma (POAG) with high myopia (HM). Seventy eyes of 70 POAG patients with HM [≤-8 diopters (D)] were examined. The mean deviation (MD) slope and the upper and lower total deviation (upper TD, lower TD) slopes of the Humphrey Field Analyzer were calculated in patients with high-tension glaucoma (HTG) (>21 mmHg) versus normal-tension glaucoma (NTG) (≤21 mmHg). The mean age of all the patients (29 eyes with HTG and 41 eyes with NTG) was 48.5 ± 9.6 years. The MD slope, and upper and lower TD slopes of the HM group were compared to those of the non-HM group (NHM) (>-8 D) selected from 544 eyes in 325 age-matched POAG patients. In all, 70 eyes with HM and NHM were examined. The mean MD slope was -0.33 ± 0.33 dB/year in the HM, and -0.38 ± 0.49 dB/year in the NHM. There were no statistical differences between the HM and NHM (p = 0.9565). In the comparison of HTG versus NTG patients in both groups, the MD slope, and upper and lower TD slopes were similar. The rate of progression of total, upper, and lower visual field defects was similar among patients with HM and NHM. Although HM is a risk factor for the onset of glaucoma, HM may not be a risk factor for progression of visual field defects as assessed by the progression rate under treatment.

  3. An artificial elementary eye with optic flow detection and compositional properties.

    PubMed

    Pericet-Camara, Ramon; Dobrzynski, Michal K; Juston, Raphaël; Viollet, Stéphane; Leitel, Robert; Mallot, Hanspeter A; Floreano, Dario

    2015-08-06

    We describe a 2 mg artificial elementary eye whose structure and functionality is inspired by compound eye ommatidia. Its optical sensitivity and electronic architecture are sufficient to generate the required signals for the measurement of local optic flow vectors in multiple directions. Multiple elementary eyes can be assembled to create a compound vision system of desired shape and curvature spanning large fields of view. The system configurability is validated with the fabrication of a flexible linear array of artificial elementary eyes capable of extracting optic flow over multiple visual directions. © 2015 The Author(s).

  4. Personal identification by eyes.

    PubMed

    Marinović, Dunja; Njirić, Sanja; Coklo, Miran; Muzić, Vedrana

    2011-09-01

    Identification of persons through the eyes is in the field of biometrical science. Many security systems are based on biometric methods of personal identification, to determine whether a person is presenting itself truly. The human eye contains an extremely large number of individual characteristics that make it particularly suitable for the process of identifying a person. Today, the eye is considered to be one of the most reliable body parts for human identification. Systems using iris recognition are among the most secure biometric systems.

  5. Objective measurement of the optical image quality in the human eye

    NASA Astrophysics Data System (ADS)

    Navarro, Rafael M.

    2001-05-01

    This communication reviews some recent studies on the optical performance of the human eye. Although the retinal image cannot be recorded directly, different objective methods have been developed, which permit to determine optical quality parameters, such as the Point Spread Function (PSF), the Modulation Transfer Function (MTF), the geometrical ray aberrations or the wavefront distortions, in the living human eye. These methods have been applied in both basic and applied research. This includes the measurement of the optical performance of the eye across visual field, the optical quality of eyes with intraocular lens implants, the aberrations induced by LASIK refractive surgery, or the manufacture of customized phase plates to compensate the wavefront aberration in the eye.

  6. Eye gaze tracking based on the shape of pupil image

    NASA Astrophysics Data System (ADS)

    Wang, Rui; Qiu, Jian; Luo, Kaiqing; Peng, Li; Han, Peng

    2018-01-01

    Eye tracker is an important instrument for research in psychology, widely used in attention, visual perception, reading and other fields of research. Because of its potential function in human-computer interaction, the eye gaze tracking has already been a topic of research in many fields over the last decades. Nowadays, with the development of technology, non-intrusive methods are more and more welcomed. In this paper, we will present a method based on the shape of pupil image to estimate the gaze point of human eyes without any other intrusive devices such as a hat, a pair of glasses and so on. After using the ellipse fitting algorithm to deal with the pupil image we get, we can determine the direction of the fixation by the shape of the pupil.The innovative aspect of this method is to utilize the new idea of the shape of the pupil so that we can avoid much complicated algorithm. The performance proposed is very helpful for the study of eye gaze tracking, which just needs one camera without infrared light to know the changes in the shape of the pupil to determine the direction of the eye gazing, no additional condition is required.

  7. Microrobots: a new era in ocular drug delivery.

    PubMed

    Fusco, Stefano; Ullrich, Franziska; Pokki, Juho; Chatzipirpiridis, George; Özkale, Berna; Sivaraman, Kartik M; Ergeneman, Olgaç; Pané, Salvador; Nelson, Bradley J

    2014-11-01

    Ocular microrobots have the potential to change the way in which we treat a variety of diseases at the anterior and the posterior segments of the eye. Wireless manipulation and positioning of drug delivery magnetic millimeter and submillimeter platforms into the eye constitute a potential route for minimally invasive targeted therapy. However, the field is still in its infancy and faces challenges related to the fabrication, control an interaction with complex biological environments. This review briefly introduces the complex anatomy and physiology of the eye, which renders limitations to the current treatments of ocular diseases. The topical administration of eye drops, intravitreal injections and drug delivery implants is briefly mentioned together with their drawbacks. The authors also analyze the minimally invasive microrobotic approach as an alternative method and report the recent advancements in the fabrication, control, manipulation and drug delivery. Although microrobotics is a young field, a significant amount of work has been developed to face different challenges related to the minimally invasive manipulation of microdevices in the eye. Current research is already at the state of in vivo testing for systems and their biocompatibility. It is expected that the general concepts acquired will soon be applied for specific interventions, especially for posterior eye pathologies.

  8. A case report of ophthalmic artery emboli secondary to Calcium Hydroxylapatite filler injection for nose augmentation- long-term outcome.

    PubMed

    Cohen, Eyal; Yatziv, Yossi; Leibovitch, Igal; Kesler, Anat; Cnaan, Ran Ben; Klein, Ainat; Goldenberg, Dafna; Habot-Wilner, Zohar

    2016-07-08

    Filler injection for face augmentation is a common cosmetic procedure in the last decades, in our case report we describe long-term outcomes of a devastating complication of ophthalmic artery emboli following Calcium Hydroxylapatite filler injection to the nose bridge. A healthy 24-year-old women received a Calcium Hydroxylapatite filler injection to her nose bridge for the correction of nose asymmetry 8 years post rhinoplasty. She developed sudden right eye ocular pain and visual disturbances. Visual acuity was 20/20 in both eyes and visual field in the right eye showed inferior arch with fixation sparing and supero-temporal central scotoma. Examination revealed marked periorbital edema and hematoma, ptosis, ocular movements limitation, an infero-temporal branch retinal artery occlusion and multiple choroidal emboli. Eighteen months post initial presentation ptosis and eye movements returned normal and choroidal emboli absorbed almost completely. However, visual acuity declined to 20/60, visual field showed severe progressive deterioration with a central and supero-nasal field remnant and the optic disc became pallor. Cosmetic injection of calcium hydroxylapatite to the nose bridge can result in arterial emboli to the ophthalmic system with optic nerve, retinal and choroidal involvement causing long term severe visual acuity and visual field impairment.

  9. Practical landmarks for visual field disability in glaucoma.

    PubMed

    Saunders, Luke J; Russell, Richard A; Crabb, David P

    2012-09-01

    To assess whether mean deviation (MD) from automated perimetry is related to the visual field (VF) component for legal fitness to drive (LFTD) in glaucoma patients. Monocular 24-2 VFs of 2604 patients with bilateral VF damage were retrospectively investigated. Integrated visual fields were calculated and used as a surrogate to assess LFTD according to current UK driving licence criteria. The better eye MD (BEMD), worse eye MD (WEMD) and a measure utilising MD of both eyes were compared, to assess respective diagnostic capabilities to predict LFTD (using the integrated visual field surrogate test as the gold standard) and a 'Probability of Failure' (PoF) for various defect levels was calculated. BEMD appears to be a good predictor of the VF component for a patient's LFTD (receiver operating characteristic area under the curve: 96.2%); MDs from both eyes offered no significant extra diagnostic power (area under the curve: 96.4%). PoF for BEMD thresholds of ≤-10 dB and ≤-14 dB were 70 (95% CI 66% to 74%) and 92% (87% to 95%), respectively. There is a strong relationship between BEMD and a patient's LFTD. PoF values for LFTD associated with readily available MD values provide practical landmarks for VF disability in glaucoma.

  10. Toward building an anatomically correct solid eye model with volumetric representation of retinal morphology

    NASA Astrophysics Data System (ADS)

    Zawadzki, Robert J.; Rowe, T. Scott; Fuller, Alfred R.; Hamann, Bernd; Werner, John S.

    2010-02-01

    An accurate solid eye model (with volumetric retinal morphology) has many applications in the field of ophthalmology, including evaluation of ophthalmic instruments and optometry/ophthalmology training. We present a method that uses volumetric OCT retinal data sets to produce an anatomically correct representation of three-dimensional (3D) retinal layers. This information is exported to a laser scan system to re-create it within solid eye retinal morphology of the eye used in OCT testing. The solid optical model eye is constructed from PMMA acrylic, with equivalent optical power to that of the human eye (~58D). Additionally we tested a water bath eye model from Eyetech Ltd. with a customized retina consisting of five layers of ~60 μm thick biaxial polypropylene film and hot melt rubber adhesive.

  11. Compound eyes of insects and crustaceans: Some examples that show there is still a lot of work left to be done.

    PubMed

    Meyer-Rochow, Victor Benno

    2015-03-01

    Similarities and differences between the 2 main kinds of compound eye (apposition and superposition) are briefly explained before several promising topics for research on compound eyes are being introduced. Research on the embryology and molecular control of the development of the insect clear-zone eye with superposition optics is one of the suggestions, because almost all of the developmental work on insect eyes in the past has focused on eyes with apposition optics. Age- and habitat-related ultrastructural studies of the retinal organization are another suggestion and the deer cad Lipoptena cervi, which has an aerial phase during which it is winged followed by a several months long parasitic phase during which it is wingless, is mentioned as a candidate species. Sexual dimorphism expressing itself in many species as a difference in eye structure and function provides another promising field for compound eye researchers and so is a focus on compound eye miniaturization in very small insects, especially those that are aquatic and belong to species, in which clear-zone eyes are diagnostic or are tiny insects that are not aquatic, but belong to taxa like the Diptera for instance, in which open rather than closed rhabdoms are the rule. Structures like interommatidial hairs and glands as well as corneal microridges are yet another field that could yield interesting results and in the past has received insufficient consideration. Finally, the dearth of information on distance vision and depth perception is mentioned and a plea is made to examine the photic environment inside the foam shelters of spittle bugs, chrysales of pupae and other structures shielding insects and crustaceans. © 2014 Institute of Zoology, Chinese Academy of Sciences.

  12. Cone Integrity in Glaucoma: An Adaptive-Optics Scanning Laser Ophthalmoscopy Study.

    PubMed

    Hasegawa, Tomoko; Ooto, Sotaro; Takayama, Kohei; Makiyama, Yukiko; Akagi, Tadamichi; Ikeda, Hanako O; Nakanishi, Hideo; Suda, Kenji; Yamada, Hiroshi; Uji, Akihito; Yoshimura, Nagahisa

    2016-11-01

    To investigate photoreceptor changes in eyes with glaucoma. Cross-sectional study. The study included 35 eyes of 35 patients with primary open-angle glaucoma who had suffered parafoveal visual field loss at least 3 years previously, as well as 21 eyes of 21 normal subjects. Eyes with an axial length ≥26.0 mm were excluded. All subjects underwent a full ophthalmologic examination, including spectral-domain optical coherence tomography (SDOCT) and prototype adaptive-optics scanning laser ophthalmoscopy (AO-SLO) imaging. As determined using AO-SLO, eyes with glaucoma did not differ significantly from normal eyes in terms of either cone density (26 468 ± 3392 cones/m 2 vs 26 147 ± 2700 cones/m 2 , respectively; P = .77; measured 0.5 mm from the foveal center) or cone spatial organization (ratio of hexagonal Voronoi domain: 43.7% ± 4.4% vs 44.3% ± 4.9%; P = .76; measured 0.5 mm from the foveal center). Furthermore, SDOCT showed that the 2 groups did not differ significantly in terms of the photoreceptor-related layer thickness, and that the photoreceptor ellipsoid zone band was continuous in all normal and glaucoma eyes. In glaucoma eyes with vertically asymmetric severity, the more affected side did not significantly differ from the less affected side in terms of cone density, cone spatial organization, or photoreceptor-related layer thickness. In 8 eyes (22.9%) with glaucoma, dark, partition-like areas surrounded the cones on the AO-SLO. Both AO-SLO and SDOCT showed cone integrity in eyes with glaucoma, even in areas with visual field and nerve fiber loss. In AO-SLO, microcystic lesions in the inner nuclear layer may influence images of the cone mosaic. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Computational see-through near-eye displays

    NASA Astrophysics Data System (ADS)

    Maimone, Andrew S.

    See-through near-eye displays with the form factor and field of view of eyeglasses are a natural choice for augmented reality systems: the non-encumbering size enables casual and extended use and large field of view enables general-purpose spatially registered applications. However, designing displays with these attributes is currently an open problem. Support for enhanced realism through mutual occlusion and the focal depth cues is also not found in eyeglasses-like displays. This dissertation provides a new strategy for eyeglasses-like displays that follows the principles of computational displays, devices that rely on software as a fundamental part of image formation. Such devices allow more hardware simplicity and flexibility, showing greater promise of meeting form factor and field of view goals while enhancing realism. This computational approach is realized in two novel and complementary see-through near-eye display designs. The first subtractive approach filters omnidirectional light through a set of optimized patterns displayed on a stack of spatial light modulators, reproducing a light field corresponding to in-focus imagery. The design is thin and scales to wide fields of view; see-through is achieved with transparent components placed directly in front of the eye. Preliminary support for focal cues and environment occlusion is also demonstrated. The second additive approach uses structured point light illumination to form an image with a minimal set of rays. Each of an array of defocused point light sources is modulated by a region of a spatial light modulator, essentially encoding an image in the focal blur. See-through is also achieved with transparent components and thin form factors and wide fields of view (>= 100 degrees) are demonstrated. The designs are examined in theoretical terms, in simulation, and through prototype hardware with public demonstrations. This analysis shows that the proposed computational near-eye display designs offer a significantly different set of trade-offs than conventional optical designs. Several challenges remain to make the designs practical, most notably addressing diffraction limits.

  14. Impact of Glaucoma and Dry Eye on Text-Based Searching.

    PubMed

    Sun, Michelle J; Rubin, Gary S; Akpek, Esen K; Ramulu, Pradeep Y

    2017-06-01

    We determine if visual field loss from glaucoma and/or measures of dry eye severity are associated with difficulty searching, as judged by slower search times on a text-based search task. Glaucoma patients with bilateral visual field (VF) loss, patients with clinically significant dry eye, and normally-sighted controls were enrolled from the Wilmer Eye Institute clinics. Subjects searched three Yellow Pages excerpts for a specific phone number, and search time was recorded. A total of 50 glaucoma subjects, 40 dry eye subjects, and 45 controls completed study procedures. On average, glaucoma patients exhibited 57% longer search times compared to controls (95% confidence interval [CI], 26%-96%, P < 0.001), and longer search times were noted among subjects with greater VF loss ( P < 0.001), worse contrast sensitivity ( P < 0.001), and worse visual acuity ( P = 0.026). Dry eye subjects demonstrated similar search times compared to controls, though worse Ocular Surface Disease Index (OSDI) vision-related subscores were associated with longer search times ( P < 0.01). Search times showed no association with OSDI symptom subscores ( P = 0.20) or objective measures of dry eye ( P > 0.08 for Schirmer's testing without anesthesia, corneal fluorescein staining, and tear film breakup time). Text-based visual search is slower for glaucoma patients with greater levels of VF loss and dry eye patients with greater self-reported visual difficulty, and these difficulties may contribute to decreased quality of life in these groups. Visual search is impaired in glaucoma and dry eye groups compared to controls, highlighting the need for compensatory strategies and tools to assist individuals in overcoming their deficiencies.

  15. Glaucoma Diagnostic Capabilities of Foveal Avascular Zone Parameters Using Optical Coherence Tomography Angiography According to Visual Field Defect Location.

    PubMed

    Kwon, Junki; Choi, Jaewan; Shin, Joong Won; Lee, Jiyun; Kook, Michael S

    2017-12-01

    To assess the diagnostic ability of foveal avascular zone (FAZ) parameters to discriminate glaucomatous eyes with visual field defects (VFDs) in different locations (central vs. peripheral) from normal eyes. Totally, 125 participants were separated into 3 groups: normal (n=45), glaucoma with peripheral VFD (PVFD, n=45), and glaucoma with central VFD (CVFD, n=35). The FAZ area, perimeter, and circularity and parafoveal vessel density were calculated from optical coherence tomography angiography images. The diagnostic ability of the FAZ parameters and other structural parameters was determined according to glaucomatous VFD location. Associations between the FAZ parameters and central visual function were evaluated. A larger FAZ area and longer FAZ perimeter were observed in the CVFD group than in the PVFD and normal groups. The FAZ area, perimeter, and circularity were better in differentiating glaucomatous eyes with CVFDs from normal eyes [areas under the receiver operating characteristic curves (AUC), 0.78 to 0.88] than in differentiating PVFDs from normal eyes (AUC, 0.51 to 0.64). The FAZ perimeter had a similar AUC value to the circumpapillary retinal nerve fiber layer and macular ganglion cell-inner plexiform layer thickness for differentiating eyes with CVFDs from normal eyes (all P>0.05, the DeLong test). The FAZ area was significantly correlated with central visual function (β=-112.7, P=0.035, multivariate linear regression). The FAZ perimeter had good diagnostic capability in differentiating glaucomatous eyes with CVFDs from normal eyes, and may be a potential diagnostic biomarker for detecting glaucomatous patients with CVFDs.

  16. Clinical Verification of Image Warping as a Potential Aid for the Visually Handicapped

    NASA Technical Reports Server (NTRS)

    Loshin, David

    1996-01-01

    The bulk of this research was to designed determine potential of the Programmable Remapper (PR) as a device to enhance vision for the visually handicapped. This research indicated that remapping would have potential as a low vision device if the eye position could be monitored with feedback to specify the proper location of the remapped image. This must be accomplished at high rate so that there is no lag of the image behind the eye position. Since at this time, there is no portable eye monitor device (at a reasonable cost) that will operate under the required conditions, it would not be feasible to continue with remapping experiments for patients with central field defects. However, since patients with peripheral field defects do not have the same eye positioning requirements, they may indeed benefit from this technology. Further investigations must be performed to determine plausibility of this application of remapping.

  17. Monocular tool control, eye dominance, and laterality in New Caledonian crows.

    PubMed

    Martinho, Antone; Burns, Zackory T; von Bayern, Auguste M P; Kacelnik, Alex

    2014-12-15

    Tool use, though rare, is taxonomically widespread, but morphological adaptations for tool use are virtually unknown. We focus on the New Caledonian crow (NCC, Corvus moneduloides), which displays some of the most innovative tool-related behavior among nonhumans. One of their major food sources is larvae extracted from burrows with sticks held diagonally in the bill, oriented with individual, but not species-wide, laterality. Among possible behavioral and anatomical adaptations for tool use, NCCs possess unusually wide binocular visual fields (up to 60°), suggesting that extreme binocular vision may facilitate tool use. Here, we establish that during natural extractions, tool tips can only be viewed by the contralateral eye. Thus, maintaining binocular view of tool tips is unlikely to have selected for wide binocular fields; the selective factor is more likely to have been to allow each eye to see far enough across the midsagittal line to view the tool's tip monocularly. Consequently, we tested the hypothesis that tool side preference follows eye preference and found that eye dominance does predict tool laterality across individuals. This contrasts with humans' species-wide motor laterality and uncorrelated motor-visual laterality, possibly because bill-held tools are viewed monocularly and move in concert with eyes, whereas hand-held tools are visible to both eyes and allow independent combinations of eye preference and handedness. This difference may affect other models of coordination between vision and mechanical control, not necessarily involving tools. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Instruction-based clinical eye-tracking study on the visual interpretation of divergence: How do students look at vector field plots?

    NASA Astrophysics Data System (ADS)

    Klein, P.; Viiri, J.; Mozaffari, S.; Dengel, A.; Kuhn, J.

    2018-06-01

    Relating mathematical concepts to graphical representations is a challenging task for students. In this paper, we introduce two visual strategies to qualitatively interpret the divergence of graphical vector field representations. One strategy is based on the graphical interpretation of partial derivatives, while the other is based on the flux concept. We test the effectiveness of both strategies in an instruction-based eye-tracking study with N =41 physics majors. We found that students' performance improved when both strategies were introduced (74% correct) instead of only one strategy (64% correct), and students performed best when they were free to choose between the two strategies (88% correct). This finding supports the idea of introducing multiple representations of a physical concept to foster student understanding. Relevant eye-tracking measures demonstrate that both strategies imply different visual processing of the vector field plots, therefore reflecting conceptual differences between the strategies. Advanced analysis methods further reveal significant differences in eye movements between the best and worst performing students. For instance, the best students performed predominantly horizontal and vertical saccades, indicating correct interpretation of partial derivatives. They also focused on smaller regions when they balanced positive and negative flux. This mixed-method research leads to new insights into student visual processing of vector field representations, highlights the advantages and limitations of eye-tracking methodologies in this context, and discusses implications for teaching and for future research. The introduction of saccadic direction analysis expands traditional methods, and shows the potential to discover new insights into student understanding and learning difficulties.

  19. Long Life Elastomeric Aircraft Hydraulic Seals. Part I2

    DTIC Science & Technology

    1974-10-01

    Aminox Antioxidant ZMB Dibutoxyethyl Sebacate Diethylhexyl Azelate Varox AFE-XN1925- ■25 AFE -XN1925- ■33 AFE -XN1925- -43 AFE -XN1925-44 95.0...Antioxidant ZMB Dibutoxyethyl Sebacate Diethylhexyl Azelate Varox AFE-XN1925-45 AFE -XN1925-46 100.0 AFE -XN192^47 100.0 100.0 5.0 5.0 5.0 5.0 5.0...Chemigum N917 Magna.sium Oxide Zinc Oxide N550 FEF N330 HAF Aminox Antioxidant ZMB Dibutoxethyl Sebacate Diethylhexyl Azelate Varox AFE

  20. EDITORIAL: The Eye and The Chip 2008 The Eye and The Chip 2008

    NASA Astrophysics Data System (ADS)

    Rizzo, Joseph F.; O'Malley, Edward R.; Hessburg, Philip C.

    2009-06-01

    Over the course of the past decade, The Eye and The Chip world congress on visual neuro-prosthetic devices has become a premier meeting for those who believe that 'artificial' vision will one day be used to improve the quality of life of visually impaired patients. Although substantial progress has been made, there are numerous unresolved issues, like the preferred methods for wireless communication, placement of devices, and materials and design among others. The Eye and The Chip meeting of 2008, held in Detroit on 12-14 June 2008, provided important new information about these and other important topics, and thus served to advance this field of scientific research. From a research seedling a decade ago to the crowd of superb presentations in Detroit last June, a very real sense of justifiable optimism has developed. The prospects of artificial vision are no longer remote. Many of the researchers expressed confidence that implantable devices will provide the hoped-for level of vision to justify their widespread use in the future. The often dramatic successes of cochlear implants continues to provide credence that artificial stimulation of nerve tissue is a plausible strategy to restore vision. The Eye and The Chip 2008 attracted researchers from four continents (North America, Europe, Asia and Australia). The meeting also benefited from the attendance and presentations by representatives of the FDA, who have been present for all The Eye and The Chip meetings. The 2008 meeting was also enhanced by the inclusion of a new and related scientific field that shares the goal of restoring vision to the blind—the field of molecular restoration of retinal function by insertion of channelrhodopsin. Just as the field of ophthalmology went from Ridley's primitive intraocular lens replacement to implants useful in virtually every cataract patient in one surgeon's clinical lifetime, the field of retinal prostheses seems to be following a very similar trajectory. Likewise, the field of visual prosthetics continues to amass evidence that suggests that its long-term future is promising. We are grateful to the scientists who made the congress a success, to the Journal of Neural Engineering for organizing this special issue, to the financial supporters who made the congress possible and to the Detroit Institute of Ophthalmology staff who worked tirelessly and without complaint to bring home a superb congress. We invite you to attend the next The Eye and The Chip meeting, which will be held in 2011.

  1. Induction soldering of photovoltaic system components

    DOEpatents

    Kumaria, Shashwat; de Leon, Briccio

    2015-11-17

    A method comprises positioning a pair of photovoltaic wafers in a side-by-side arrangement. An interconnect is placed on the pair of wafers such that the interconnect overlaps both wafers of the pair, solder material being provided between the interconnect and the respective wafers. A solder head is then located adjacent the interconnect, and the coil is energized to effect inductive heating of the solder material. The solder head comprises an induction coil shaped to define an eye, and a magnetic field concentrator located at least partially in the eye of the coil. The magnetic field concentrator defines a passage extending axially through the eye of the coil, and may be of a material with a high magnetic permeability.

  2. Progressive Decrease of Peripapillary Angioflow Vessel Density During Structural and Visual Field Progression in Early Primary Open-angle Glaucoma.

    PubMed

    Holló, Gábor

    2017-07-01

    To present a case of early primary open-angle glaucoma in which retinal nerve fiber layer thickness (RNFLT), ganglion cell complex (GCC), and visual field progression were accompanied with significant progression of peripapillary angioflow vessel density (PAFD) measured with optical coherence tomographic angiography. A 68-year-old female patient who was under topical intraocular pressure (IOP) lowering medication for 20 years for ocular hypertension of the right and preperimetric primary open-angle glaucoma of the left eye (with reproducible inferotemporal and superotemporal neuroretinal rim and RNFL loss) was prospectively imaged with the AngioVue OCT for RNFLT, GCC thickness, and PAFD, and investigated with the Octopus Normal G2 visual field test on the same days at 6-month intervals for 18 months, while the IOP of the left eye escaped from control. IOP of the left eye fluctuated between 14 and 30 mm Hg in the study period. RNFLT, GCC thickness, and peripapillary PAFD all decreased significantly (linear regression analysis, P=0.030, 0.040, and 0.020, respectively), and a significant 2.1 dB/y progression was seen for a superior visual field cluster. The RNFLT, peripapillary PAFD, and visual field of the right eye remained normal and unchanged. In our case IOP elevation, glaucomatous visual field conversion, and structural progression were accompanied with significant progressive decrease of peripapillary PAFD. The simultaneous thinning of RNFLT and GCC and decrease of peripapillary PAFD suggest that PAFD may potentially be an additional indicator of early progression in primary open-angle glaucoma.

  3. Teachers' Experiences of Using Eye Gaze-Controlled Computers for Pupils with Severe Motor Impairments and without Speech

    ERIC Educational Resources Information Center

    Rytterström, Patrik; Borgestig, Maria; Hemmingsson, Helena

    2016-01-01

    The purpose of this study is to explore teachers' experiences of using eye gaze-controlled computers with pupils with severe disabilities. Technology to control a computer with eye gaze is a fast growing field and has promising implications for people with severe disabilities. This is a new assistive technology and a new learning situation for…

  4. Eye-bank preparation of endothelial tissue.

    PubMed

    Boynton, Grace E; Woodward, Maria A

    2014-07-01

    Eye-bank preparation of endothelial tissue for keratoplasty continues to evolve. Although eye-bank personnel have become comfortable and competent at Descemet's stripping automated endothelial keratoplasty (DSAEK), tissue preparation and tissue transport, optimization of preparation methods continues. Surgeons and eye-bank personnel should be up to date on the research in the field. As surgeons transit to Descemet's membrane endothelial keratoplasty (DMEK), eye banks have risen to the challenge of preparing tissue. Eye banks are refining their DMEK preparation and transport techniques. This article covers refinements to DSAEK tissue preparation, innovations to prepare DMEK tissue, and nuances to improve donor cornea tissue quality. As eye bank-supplied corneal tissue is the main source of tissue for many corneal surgeons, it is critical to stay informed about tissue handling and preparation. Ultimately, the surgeon is responsible for the transplantation, so involvement of clinicians in eye-banking practices and advocacy for pursuing meaningful research in this area will benefit clinical patient outcomes.

  5. Comparison of Wide-Field Fluorescein Angiography and Nine-Field Montage Angiography in Uveitis

    PubMed Central

    Nicholson, Benjamin P.; Nigam, Divya; Miller, Darby; Agrón, Elvira; Dalal, Monica; Jacobs-El, Naima; Lima, Breno da Rocha; Cunningham, Denise; Nussenblatt, Robert; Sen, H. Nida

    2014-01-01

    Purpose To qualitatively and quantitatively compare Optos© fundus camera fluorescein angiographic images of retinal vascular leakage with 9-field montage Topcon© fluorescein angiography (FA) images in patients with uveitis. We hypothesized that Optos images reveal more leakage in uveitis patients. Design Retrospective, observational case series. Methods Images of all uveitis patients imaged with same-sitting Optos FA and 9-field montage FA during a 9 month period at a single institution (52 eyes of 31 patients) were graded for the total area of retinal vascular leakage. The main outcome measure was area of fluorescein leakage. Results The area of apparent FA leakage was greater in Optos images than in 9-field montage images (median 22.5 mm2 vs. 4.8 mm2, P<0.0001). Twenty-two of 49 (45%) eyes with gradable photos had at least 25% more leakage on the Optos image than on the montage image. Two (4.1%) had at least 25% less leakage on Optos, and 25 (51%) were similar between the two modalities. Two eyes had no apparent retinal vascular leakage on 9-field montage but were found to have apparent leakage on Optos images. Twenty-three of the 49 eyes had posterior pole leakage, and of these 17 (73.9%) showed more posterior pole leakage on the Optos image. A single 200 degree Optos FA image captured a mean 1.50x the area captured by montage photography. Conclusion More retinal vascular pathology, both in the periphery and the posterior pole, is seen with Optos FA in uveitis patients when compared with 9-field montage. The clinical implications of Optos FA findings have yet to be determined. PMID:24321475

  6. Nerve Fiber Flux Analysis Using Wide-Field Swept-Source Optical Coherence Tomography.

    PubMed

    Tan, Ou; Liu, Liang; Liu, Li; Huang, David

    2018-02-01

    To devise a method to quantify nerve fibers over their arcuate courses over an extended peripapillary area using optical coherence tomography (OCT). Participants were imaged with 8 × 8-mm volumetric OCT scans centered at the optic disc. A new quantity, nerve fiber flux (NFF), represents the cross-sectional area transected perpendicular to the nerve fibers. The peripapillary area was divided into 64 tracks with equal flux. An iterative algorithm traced the trajectory of the tracks assuming that the relative distribution of the NFF was conserved with compensation for fiber connections to ganglion cells on the macular side. Average trajectory was averaged from normal eyes and use to calculate the NFF maps for glaucomatous eyes. The NFF maps were divided into eight sectors that correspond to visual field regions. There were 24 healthy and 10 glaucomatous eyes enrolled. The algorithm converged on similar patterns of NFL tracks for all healthy eyes. In glaucomatous eyes, NFF correlated with visual field sensitivity in the arcuate sectors (Spearman ρ = 0.53-0.62). Focal nerve fiber loss in glaucomatous eyes appeared as uniform tracks of NFF defects that followed the expected arcuate fiber trajectory. Using an algorithm based on the conservation of flux, we derived nerve fiber trajectories in the peripapillary area. The NFF map is useful for the visualization of focal defects and quantification of sector nerve fiber loss from wide-area volumetric OCT scans. NFF provides a cumulative measure of volumetric loss along nerve fiber tracks and could improve the detection of focal glaucoma damage.

  7. Attention in dichoptic and binocular vision

    NASA Technical Reports Server (NTRS)

    Kimchi, Ruth; Rubin, Yifat; Gopher, Daniel; Raij, David

    1989-01-01

    The ability of human subjected to mobilize attention and cope with task requirements under dichoptic and binocular viewing was investigated in an experiment employing a target search task. Subjects were required to search for a target at either the global level, the local level, or at both levels of a compound stimulus. The tasks were performed in a focused attention condition in which subjects had to attend to the stimulus presented to one eye/field (under dichoptic and binocular viewings, respectively) and to ignore the stimulus presented to the irrelevant eye/field, and in a divided attention condition in which subjects had to attend to the stimuli presented to both eyes/fields. Subjects' performance was affected mainly by attention conditions which interacted with task requirements, rather than by viewing situation. An interesting effect of viewing was found for the local-directed search task in which the cost of dividing attention was higher under binocular than under dichoptic viewing.

  8. The effect of topical anesthesia on the rat electroretinogram.

    PubMed

    Sandalon, Shai; Ofri, Ron

    2009-04-01

    Topical anesthetics are recommended when electroretinograms (ERGs) are recorded using contact lens electrodes. However, these drugs act by blocking voltage-gated Na+ channels. Since such channels have been located in both the inner and outer retina of many species, topical anesthesia could affect the ERG recordings in these subjects. The purpose of this study was to evaluate the effects of oxybuprocaine, a commonly used ester local anesthetic, on the rat ERG. Full-field scotopic and pattern ERGs (PERGs) were recorded successively from both eyes of seven rats. One eye was randomly treated with oxybuprocaine 15 min prior to recording. In 10 rats unilateral full-field photopic ERG recordings were conducted prior to, and 15 min after, treatment. B-wave amplitude ratios of the experimental/control eyes were 1.13, 1.30, and 1.35 for the three intensities used to record scotopic ERG responses, and 1.04 for the photopic ERG responses. PERG amplitude ratios of the experimental/control eyes were 1.10, 1.21, 1.21, 1.24, and 1.26 for the five patterns used. Treatment had no significant negative effect on signal amplitude or implicit time of the full-field ERG or PERG. In fact, amplitudes of signals from treated eyes tended to be (insignificantly) higher, though this might reflect better position of the active electrode rather than a biological effect. We conclude that oxybuprocaine has no negative effect on the rat ERG.

  9. Chronic Electromagnetic Exposure at Occupational Safety Level Does Not Affect the Metabolic Profile nor Cornea Healing after LASIK Surgery

    PubMed Central

    Dabouis, Vincent; Gentilhomme, Edgar; Vignal, Rodolphe; Bourbon, Fréderic; Fauvelle, Florence; Debouzy, Jean-Claude

    2014-01-01

    LASIK eye surgery has become a very common practice for myopic people, especially those in the military. Sometimes undertaken by people who need to keep a specific medical aptitude, this surgery could be performed in secret from the hierarchy and from the institute medical staff. However, even though the eyes have been previously described as one of the most sensitive organs to electromagnetic fields in the human body, no data exist on the potential deleterious effects of electromagnetic fields on the healing eye. The consequences of chronic long-lasting radar exposures at power density, in accordance with the occupational safety standards (9.71 GHz, 50 W/m2), were investigated on cornea healing. The metabolic and clinical statuses after experimental LASIK keratotomy were assessed on the different eye segments in a New Zealand rabbit model. The analysis methods were performed after 5 months of exposure (1 hour/day, 3 times/week). Neither clinical or histological examinations, nor experimental data, such as light scattering, 1H-NMR HRMAS metabolomics, 13C-NMR spectra of lipidic extracts, and antioxidant status, evidenced significant modifications. It was concluded that withdrawing the medical aptitude of people working in electromagnetic field environments (i.e., radar operators in the navy) after eye surgery was not justified. PMID:24757560

  10. Driving with Binocular Visual Field Loss? A Study on a Supervised On-Road Parcours with Simultaneous Eye and Head Tracking

    PubMed Central

    Aehling, Kathrin; Heister, Martin; Rosenstiel, Wolfgang; Schiefer, Ulrich; Papageorgiou, Elena

    2014-01-01

    Post-chiasmal visual pathway lesions and glaucomatous optic neuropathy cause binocular visual field defects (VFDs) that may critically interfere with quality of life and driving licensure. The aims of this study were (i) to assess the on-road driving performance of patients suffering from binocular visual field loss using a dual-brake vehicle, and (ii) to investigate the related compensatory mechanisms. A driving instructor, blinded to the participants' diagnosis, rated the driving performance (passed/failed) of ten patients with homonymous visual field defects (HP), including four patients with right (HR) and six patients with left homonymous visual field defects (HL), ten glaucoma patients (GP), and twenty age and gender-related ophthalmologically healthy control subjects (C) during a 40-minute driving task on a pre-specified public on-road parcours. In order to investigate the subjects' visual exploration ability, eye movements were recorded by means of a mobile eye tracker. Two additional cameras were used to monitor the driving scene and record head and shoulder movements. Thus this study is novel as a quantitative assessment of eye movements and an additional evaluation of head and shoulder was performed. Six out of ten HP and four out of ten GP were rated as fit to drive by the driving instructor, despite their binocular visual field loss. Three out of 20 control subjects failed the on-road assessment. The extent of the visual field defect was of minor importance with regard to the driving performance. The site of the homonymous visual field defect (HVFD) critically interfered with the driving ability: all failed HP subjects suffered from left homonymous visual field loss (HL) due to right hemispheric lesions. Patients who failed the driving assessment had mainly difficulties with lane keeping and gap judgment ability. Patients who passed the test displayed different exploration patterns than those who failed. Patients who passed focused longer on the central area of the visual field than patients who failed the test. In addition, patients who passed the test performed more glances towards the area of their visual field defect. In conclusion, our findings support the hypothesis that the extent of visual field per se cannot predict driving fitness, because some patients with HVFDs and advanced glaucoma can compensate for their deficit by effective visual scanning. Head movements appeared to be superior to eye and shoulder movements in predicting the outcome of the driving test under the present study scenario. PMID:24523869

  11. Site of potential operating microscope light-induced phototoxicity on the human retina during temporal approach eye surgery.

    PubMed

    Pavilack, M A; Brod, R D

    2001-02-01

    To determine the site of focal illumination on the retina of phakic human cadaver eyes from an operating microscope positioned for temporal approach eye surgery. Experimental study. A Zeiss OPMI-6SFR operating microscope (Zeiss Humphrey Systems, Dublin, CA) was positioned over two phakic human cadaver eyes to measure the site of the focal illumination on the retina by directly observing the illumination on the posterior scleral surface of the globe. External localization of the foveola was made by direct observation using scleral indentation and indirect ophthalmoscopy. Various combinations of microscope angulation and field of view were analyzed. Distance of focal illumination from the operating room microscope relative to the foveola was measured. The diameter of the "hot spot" of focal illumination on the retina was 4.0 mm. With the eye positioned straight ahead and the level operating room microscope positioned for temporal approach eye surgery, the center of retinal illumination was 0.9 and 1.4 mm nasal relative to the foveola when the microscope field of view was centered over the cornea and temporal limbus, respectively. With the microscope angled 5, 10, 15, and 20 degrees temporally (oculars tilted toward surgeon), the center of the illumination was displaced nasal to the foveola by 1.1, 1.5, 3.8, and 5.1 mm, respectively, when the field of view was centered over the cornea and 1.5, 2.6, 4.7, and 6.0 mm, respectively, nasal to the foveola when centered over the temporal limbus. Retinal illumination from an operating microscope positioned for temporal approach eye surgery has the potential for light-induced injury to the fovea. Angulation of the operating microscope by up to 10 degrees temporally when the microscope field of view was centered over the cornea and up to 5 degrees temporally when centered over the temporal limbus was not adequate to displace the focal illumination off the foveola when the eye was in the straight-ahead position. Tilting the operating microscope 15 degrees or more temporally when centered on the pupil and 10 degrees or more when centered over the temporal limbus should safely displace the retinal light exposure away from the fovea during temporal approach surgery. Suggestions for reducing the risk of iatrogenic phototoxicity are reviewed.

  12. Penetrating eye injury in war.

    PubMed

    Biehl, J W; Valdez, J; Hemady, R K; Steidl, S M; Bourke, D L

    1999-11-01

    The percentage of penetrating eye injuries in war has increased significantly in this century compared with the total number of combat injuries. With the increasing use of fragmentation weapons and possibly laser weapons on the battle-field in the future, the rate of eye injuries may exceed the 13% of the total military injuries found in Operations Desert Storm/Shield. During the Iran-Iraq War (1980-1988), eye injuries revealed that retained foreign bodies and posterior segment injuries have an improved prognosis in future military ophthalmic surgery as a result of modern diagnostic and treatment modalities. Compared with the increasing penetrating eye injuries on the battlefield, advances in ophthalmic surgery are insignificant. Eye armor, such as visors that flip up and down and protect the eyes from laser injury, needs to be developed. Similar eye protection is being developed in civilian sportswear. Penetrating eye injury in the civilian sector is becoming much closer to the military model and is now comparable for several reasons.

  13. Seeing the future: using Xenopus to understand eye regeneration.

    PubMed

    Tseng, Ai-Sun

    2017-01-01

    Studies of Xenopus eye development have contributed considerably to the understanding of vertebrate neurogenesis, including eye field specification, cell fate determination and identification of genes critical for eye formation. This knowledge has served as a solid foundation for cellular and molecular examinations of the robust regenerative capacity of the Xenopus eye. The retina, lens, and the optic nerve are capable of regeneration after injury in both larval and adult stages. Here, we discuss the current models for studying eye regeneration in Xenopus and their potential applications for providing insights into human eye diseases. As Xenopus has many of the same tools that are available for other regeneration models, we thus highlight the distinct strengths and versatility of this organism that make it especially suited for extrapolating and testing strategies aimed at promoting regeneration and repair in eye tissues. Furthermore, we outline a promising future for the use of new techniques and approaches to address outstanding questions in understanding eye regeneration. © 2017 Wiley Periodicals, Inc.

  14. Optical coherence tomography measurement of the retinal nerve fiber layer in normal and juvenile glaucomatous eyes.

    PubMed

    Mrugacz, Malgorzata; Bakunowicz-Lazarczyk, Alina

    2005-01-01

    The aim of this study was to quantitatively assess and compare the thickness of the retinal nerve fiber layer (RNFL) in normal and glaucomatous eyes of children using the optical coherence tomograph. The mean RNFL thickness of normal eyes (n=26) was compared with that of glaucomatous eyes (n=26). The eyes were classified into diagnostic groups based on conventional ophthalmological physical examination, Humphrey 30-2 visual fields, stereoscopic optic nerve head photography, and optical coherence tomography. The mean RNFL was significantly thinner in glaucomatous eyes than in normal eyes: 95+/-26.3 and 132+/-24.5 microm, respectively. More specifically, the RNFL was significantly thinner in glaucomatous eyes than in normal eyes in the inferior quadrant: 87+/-23.5 and 122+/-24.2 microm, respectively. The mean and inferior quadrant RFNL thicknesses as measured by the optical coherence tomograph showed a statistically significant correlation with glaucoma. Optical coherence tomography may contribute to tracking of juvenile glaucoma progression. Copyright (c) 2005 S. Karger AG, Basel.

  15. Effect of a patient training video on visual field test reliability

    PubMed Central

    Sherafat, H; Spry, P G D; Waldock, A; Sparrow, J M; Diamond, J P

    2003-01-01

    Aims: To evaluate the effect of a visual field test educational video on the reliability of the first automated visual field test of new patients. Methods: A prospective, randomised, controlled trial of an educational video on visual field test reliability of patients referred to the hospital eye service for suspected glaucoma was undertaken. Patients were randomised to either watch an educational video or a control group with no video. The video group was shown a 4.5 minute audiovisual presentation to familiarise them with the various aspects of visual field examination with particular emphasis on sources of unreliability. Reliability was determined using standard criteria of fixation loss rate less than 20%, false positive responses less than 33%, and false negative responses less than 33%. Results: 244 patients were recruited; 112 in the video group and 132 in the control group with no significant between group difference in age, sex, and density of field defects. A significant improvement in reliability (p=0.015) was observed in the group exposed to the video with 85 (75.9%) patients having reliable results compared to 81 (61.4%) in the control group. The difference was not significant for the right (first tested) eye with 93 (83.0%) of the visual fields reliable in the video group compared to 106 (80.0%) in the control group (p = 0.583), but was significant for the left (second tested) eye with 97 (86.6 %) of the video group reliable versus 97 (73.5%) of the control group (p = 0.011). Conclusions: The use of a brief, audiovisual patient information guide on taking the visual field test produced an improvement in patient reliability for individuals tested for the first time. In this trial the use of the video had most of its impact by reducing the number of unreliable fields from the second tested eye. PMID:12543740

  16. Effect of a patient training video on visual field test reliability.

    PubMed

    Sherafat, H; Spry, P G D; Waldock, A; Sparrow, J M; Diamond, J P

    2003-02-01

    To evaluate the effect of a visual field test educational video on the reliability of the first automated visual field test of new patients. A prospective, randomised, controlled trial of an educational video on visual field test reliability of patients referred to the hospital eye service for suspected glaucoma was undertaken. Patients were randomised to either watch an educational video or a control group with no video. The video group was shown a 4.5 minute audiovisual presentation to familiarize them with the various aspects of visual field examination with particular emphasis on sources of unreliability. Reliability was determined using standard criteria of fixation loss rate less than 20%, false positive responses less than 33%, and false negative responses less than 33%. 244 patients were recruited; 112 in the video group and 132 in the control group with no significant between group difference in age, sex, and density of field defects. A significant improvement in reliability (p=0.015) was observed in the group exposed to the video with 85 (75.9%) patients having reliable results compared to 81 (61.4%) in the control group. The difference was not significant for the right (first tested) eye with 93 (83.0%) of the visual fields reliable in the video group compared to 106 (80.0%) in the control group (p = 0.583), but was significant for the left (second tested) eye with 97 (86.6 %) of the video group reliable versus 97 (73.5%) of the control group (p = 0.011). The use of a brief, audiovisual patient information guide on taking the visual field test produced an improvement in patient reliability for individuals tested for the first time. In this trial the use of the video had most of its impact by reducing the number of unreliable fields from the second tested eye.

  17. Fixation Patterns and Reading Rates in Eyes with Central Scotomas from Advanced Atrophic Age-related Macular Degeneration and Stargardt Disease

    PubMed Central

    Sunness, Janet S.; Applegate, Carol A.; Haselwood, David; Rubin, Gary S.

    2009-01-01

    Purpose To study fixation patterns and reading rates in eyes with central scotomas from geographic atrophy (GA) of age-related macular degeneration and to compare fixation patterns with those of patients with Stargardt disease. Methods Scanning laser ophthalmoscope analysis of fixation patterns in eyes with 20/80 to 20/200 visual acuity. Included were 41 eyes of 35 patients with GA and 10 eyes of 5 patients with Stargardt disease. The patients with GA also were tested for maximum reading rate, and the size of the areas of atrophy were measured by fundus photograph analysis. Results Sixty-three percent of GA eyes fixating outside the atrophy placed the scotoma to the right of fixation in visual field space, 22% placed the scotoma above fixation, and 15% placed it to the left, regardless of the laterality of the GA eye. Fixation was stable in subsequent years of testing for scotoma placement to the right of or above fixation. All GA eyes fixated immediately adjacent to the atrophy. In contrast, seven of ten eyes with Stargardt disease fixated at a considerable distance from the scotoma border, with the dense scotoma far above the fixation site in visual field space. For the patients with GA, the maximum reading rate was highly correlated with size of the atrophic area, but not with age or visual acuity within the limited visual acuity range tested. There was a trend to more rapid reading with the scotoma above fixation and slower reading with the scotoma to the left. Conclusion There is a preference for fixation with the scotoma to the right in eyes with GA. Patients with Stargardt disease use different strategies for fixation, perhaps due to subclinical pathology adjacent to the atrophic regions. The size of the atrophic area in GA plays the predominant role in reading rate for eyes that have already lost foveal vision. PMID:8841306

  18. Optics of wide-angle panoramic viewing system-assisted vitreous surgery.

    PubMed

    Chalam, Kakarla V; Shah, Vinay A

    2004-01-01

    The purpose of the article is to describe the optics of the contact wide-angle lens system with stereo-reinverter for vitreous surgery. A panoramic viewing system is made up of two components; an indirect ophthalmoscopy lens system for fundus image viewing, which is placed on the patient's cornea as a contact lens, and a separate removable prism system for reinversion of the image mounted on the microscope above the zooming system. The system provides a 104 degrees field of view in a phakic emmetropic eye with minification, which can be magnified by the operating microscope. It permits a binocular stereoptic view even through a small pupil (3 mm) or larger. In an air-filled phakic eye, field of view increases to approximately 130 degrees. The obtained image of the patient's fundus is reinverted to form true, erect, stereoscopic image by the reinversion system. In conclusion, this system permits wide-angle panoramic view of the surgical field. The contact lens neutralizes the optical irregularities of the corneal surface and allows improved visualization in eyes with irregular astigmatism induced by corneal scars. Excellent visualization is achieved in complex clinical situations such as miotic pupils, lenticular opacities, and in air-filled phakic eyes.

  19. Solar retinopathy. A study from Nepal and from Germany.

    PubMed

    Rai, N; Thuladar, L; Brandt, F; Arden, G B; Berninger, T A

    1998-01-01

    319 patients with a solar retinopathy were seen in an eye clinic in Nepal within 20 months. All patients had either a positive history of sun-gazing or typical circumscribed scars in the foveal area. In more than 80% of the patients the visual acuity was 6/12 or better and did not deteriorate over time. 126 (40%) patients had a history of gazing at the sun during an eclipse, 33 (10%) were sun worshipers and 4 (1%) were in both categories. Three years later 29 patients were re-examined in a follow-up study. Only 16 had had visual disturbances directly after they had gazed into the sun. No colour vision defects were seen in any of the 44 affected eyes, when tested with Panel D 15, while four patients (6 eyes) had some uncertainty with the tritan plates of the Ishihara test charts. Metamorphopsia were recorded in 11 eyes. Five German patients with solar retinopathy were examined in more detail. Colour contrast sensitivity (CCS) was tested for the central and the peripheral visual field. CCS for tritan axis was raised in all patients for the central visual field, while it was normal for the peripheral visual field.

  20. Low vision system for rapid near- and far-field magnification switching.

    PubMed

    Ambrogi, Nicholas; Dias-Carlson, Rachel; Gantner, Karl; Gururaj, Anisha; Hanumara, Nevan; Narain, Jaya; Winter, Amos; Zielske, Iris; Satgunam, PremNandhini; Bagga, Deepak Kumar; Gothwal, Vijaya

    2015-01-01

    People suffering from low vision, a condition caused by a variety of eye-related diseases and/or disorders, find their ability to read greatly improved when text is magnified between 2 and 6 times. Assistive devices currently on the market are either geared towards reading text far away (~20 ft.) or very near (~2 ft.). This is a problem especially for students suffering from low vision, as they struggle to flip their focus between the chalkboard (far-field) and their notes (near- field). A solution to this problem is of high interest to eye care facilities in the developing world - no devices currently exist that have the aforementioned capabilities at an accessible price point. Through consultation with specialists at L.V. Prasad Eye Institute in India, the authors propose, design and demonstrate a device that fills this need, directed primarily at the Indian market. The device utilizes available hardware technologies to electronically capture video ahead of the user and zoom and display the image in real-time on LCD screens mounted in front of the user's eyes. This design is integrated as a wearable system in a glasses form-factor.

  1. The Monocular Duke of Urbino.

    PubMed

    Schwartz, Stephen G; Leffler, Christopher T; Chavis, Pamela S; Khan, Faraaz; Bermudez, Dennis; Flynn, Harry W

    2016-01-01

    Federico da Montefeltro (1422-1482), the Duke of Urbino, was a well-known historical figure during the Italian Renaissance. He is the subject of a famous painting by Piero della Francesca (1416-1492), which displays the Duke from the left and highlights his oddly shaped nose. The Duke is known to have lost his right eye due to an injury sustained during a jousting tournament, which is why the painting portrays him from the left. Some historians teach that the Duke subsequently underwent nasal surgery to remove tissue from the bridge of his nose in order to expand his visual field in an attempt to compensate for the lost eye. In theory, removal of a piece of the nose may have expanded the nasal visual field, especially the "eye motion visual field" that encompasses eye movements. In addition, removing part of the nose may have reduced some of the effects of ocular parallax. Finally, shifting of the visual egocenter may have occurred, although this seems likely unrelated to the proposed nasal surgery. Whether or not the Duke actually underwent the surgery cannot be proven, but it seems unlikely that this would have substantially improved his visual function.

  2. Some characteristics of optokinetic eye-movement patterns : a comparative study.

    DOT National Transportation Integrated Search

    1970-07-01

    Long-associated with transportation ('railroad nystagmus'), optokinetic (OPK) nystagmus is an eye-movement reaction which occurs when a series of moving objects crosses the visual field or when an observer moves past a series of objects. Similar cont...

  3. Monocular focal retinal lesions induce short-term topographic plasticity in adult cat visual cortex.

    PubMed Central

    Calford, M B; Schmid, L M; Rosa, M G

    1999-01-01

    Electrophysiological recording in primary visual cortex (VI) was performed both prior to and in the hours immediately following the creation of a discrete retinal lesion in one eye with an argon laser. Lesion projection zones (LPZs; 21-64 mm2) were defined in the visual cortex by mapping the extent of the lesion onto the topographic representation in cortex. There was no effect on neuronal responses to the unlesioned eye or on its topographic representation. However, within hours of producing the retinal lesion, receptive fields obtained from stimulation of the lesioned eye were displaced onto areas surrounding the scotoma and were enlarged compared with the corresponding field obtained through the normal eye. The proportion of such responsive recording sites increased during the experiment such that 8-11 hours post-lesion, 56% of recording sites displayed neurons responsive to the lesioned eye. This is an equivalent proportion to that previously reported with long-term recovery (three weeks to three months). Responsive neurons were evident as far as 2.5 mm inside the border of the LPZ. The reorganization of the lesioned eye representation produced binocular disparities as great as 15 degrees, suggesting interactions between sites in VI up to 5.5 mm apart. PMID:10189714

  4. Eye-Tracking Technology and the Dynamics of Natural Gaze Behavior in Sports: A Systematic Review of 40 Years of Research.

    PubMed

    Kredel, Ralf; Vater, Christian; Klostermann, André; Hossner, Ernst-Joachim

    2017-01-01

    Reviewing 60 studies on natural gaze behavior in sports, it becomes clear that, over the last 40 years, the use of eye-tracking devices has considerably increased. Specifically, this review reveals the large variance of methods applied, analyses performed, and measures derived within the field. The results of sub-sample analyses suggest that sports-related eye-tracking research strives, on the one hand, for ecologically valid test settings (i.e., viewing conditions and response modes), while on the other, for experimental control along with high measurement accuracy (i.e., controlled test conditions with high-frequency eye-trackers linked to algorithmic analyses). To meet both demands, some promising compromises of methodological solutions have been proposed-in particular, the integration of robust mobile eye-trackers in motion-capture systems. However, as the fundamental trade-off between laboratory and field research cannot be solved by technological means, researchers need to carefully weigh the arguments for one or the other approach by accounting for the respective consequences. Nevertheless, for future research on dynamic gaze behavior in sports, further development of the current mobile eye-tracking methodology seems highly advisable to allow for the acquisition and algorithmic analyses of larger amounts of gaze-data and further, to increase the explanatory power of the derived results.

  5. Impact of Glaucoma and Dry Eye on Text-Based Searching

    PubMed Central

    Sun, Michelle J.; Rubin, Gary S.; Akpek, Esen K.; Ramulu, Pradeep Y.

    2017-01-01

    Purpose We determine if visual field loss from glaucoma and/or measures of dry eye severity are associated with difficulty searching, as judged by slower search times on a text-based search task. Methods Glaucoma patients with bilateral visual field (VF) loss, patients with clinically significant dry eye, and normally-sighted controls were enrolled from the Wilmer Eye Institute clinics. Subjects searched three Yellow Pages excerpts for a specific phone number, and search time was recorded. Results A total of 50 glaucoma subjects, 40 dry eye subjects, and 45 controls completed study procedures. On average, glaucoma patients exhibited 57% longer search times compared to controls (95% confidence interval [CI], 26%–96%, P < 0.001), and longer search times were noted among subjects with greater VF loss (P < 0.001), worse contrast sensitivity (P < 0.001), and worse visual acuity (P = 0.026). Dry eye subjects demonstrated similar search times compared to controls, though worse Ocular Surface Disease Index (OSDI) vision-related subscores were associated with longer search times (P < 0.01). Search times showed no association with OSDI symptom subscores (P = 0.20) or objective measures of dry eye (P > 0.08 for Schirmer's testing without anesthesia, corneal fluorescein staining, and tear film breakup time). Conclusions Text-based visual search is slower for glaucoma patients with greater levels of VF loss and dry eye patients with greater self-reported visual difficulty, and these difficulties may contribute to decreased quality of life in these groups. Translational Relevance Visual search is impaired in glaucoma and dry eye groups compared to controls, highlighting the need for compensatory strategies and tools to assist individuals in overcoming their deficiencies. PMID:28670502

  6. Refraction and the axial length of the eyeball in patients with the optic disc drusen.

    PubMed

    Obuchowska, Iwona; Mariak, Zofia

    2009-01-01

    The aim of the study was to demonstrate the relationship between the optic disc drusen (ODD) and the axial length of the eyeball as well as refractive error. We examined prospectively 40 patients with ODD, 18 men and 22 women, age range from 34 to 69 years. All subjects underwent full ophthalmic examination, visual field testing and color-coded duplex sonography of the ocular vessels. Refraction was determined with an autorefractometer (Topcon RM-8000B) and further refined subjectively. Spherical equivalent refraction was calculated as the spherical dioptre plus one half of the cylindrical dioptre. Axial lengths were measured with a Sonomed ultrasound scanner model E-Z Scan AB5500. Clinical signs were observed in 65% of the eyes with drusen, among them, 38% had symptoms of visual acuity loss and all had visual fields defects. There were 21 eyes (18 eyes with and 3 without drusen), with a recorded refractive error. Significant differences in hyperopia were observed between the eyes with and without drusen (p = 0.048). The rate of occurrence of myopia did not differ significantly between affected and unaffected eyes (p = 0.06). The mean spherical equivalent refraction and axial dimensions of the eye differed significantly among the groups of eyes with and without drusen (p < 0.05). Significant differences in mean values of peak-systolic and end-diastolic velocities (p < 0.001) as well as in the resistivity index (p = 0.047) were observed between eyes with and without drusen. The optic disc drusen are often associated with shorter and hyperopic eyes. This anatomical conditions and vascular factors may contribute to pathogenesis of drusen.

  7. Effect of the incidence angle to free space optical communication based on cat-eye modulating retro-reflector

    NASA Astrophysics Data System (ADS)

    Zhang, Lai-xian; Sun, Hua-yan; Zhao, Yan-zhong; Zheng, Yong-hui; Shan, Cong-miao

    2013-08-01

    Based on the cat-eye effect of optical system, free space optical communication based on cat-eye modulating retro-reflector can build communication link rapidly. Compared to classical free space optical communication system, system based on cat-eye modulating retro-reflector has great advantages such as building communication link more rapidly, a passive terminal is smaller, lighter and lower power consuming. The incident angle is an important factor of cat-eye effect, so it will affect the retro-reflecting communication link. In this paper, the principle and work flow of free space optical communication based on cat-eye modulating retro-reflector were introduced. Then, using the theory of geometric optics, the equivalent model of modulating retro-reflector with incidence angle was presented. The analytical solution of active area and retro-reflected light intensity of cat-eye modulating retro-reflector were given. Noise of PIN photodetector was analyzed, based on which, bit error rate of free space optical communication based on cat-eye modulating retro-reflector was presented. Finally, simulations were done to study the effect of incidence angle to the communication. The simulation results show that the incidence angle has little effect on active area and retro-reflected light intensity when the incidence beam is in the active field angle of cat-eye modulating retro-reflector. With certain system and condition, the communication link can rapidly be built when the incidence light beam is in the field angle, and the bit error rate increases greatly with link range. When link range is smaller than 35Km, the bit error rate is less than 10-16.

  8. Design of retinal-projection-based near-eye display with contact lens.

    PubMed

    Wu, Yuhang; Chen, Chao Ping; Mi, Lantian; Zhang, Wenbo; Zhao, Jingxin; Lu, Yifan; Guo, Weiqian; Yu, Bing; Li, Yang; Maitlo, Nizamuddin

    2018-04-30

    We propose a design of a retinal-projection-based near-eye display for achieving ultra-large field of view, vision correction, and occlusion. Our solution is highlighted by a contact lens combo, a transparent organic light-emitting diode panel, and a twisted nematic liquid crystal panel. Its design rules are set forth in detail, followed by the results and discussion regarding the field of view, angular resolution, modulation transfer function, contrast ratio, distortion, and simulated imaging.

  9. Stem Cell Ophthalmology Treatment Study (SCOTS) for retinal and optic nerve diseases: a case report of improvement in relapsing auto-immune optic neuropathy.

    PubMed

    Weiss, Jeffrey N; Levy, Steven; Benes, Susan C

    2015-09-01

    We present the results from a patient with relapsing optic neuropathy treated within the Stem Cell Ophthalmology Treatment Study (SCOTS). SCOTS is an Institutional Review Board approved clinical trial and has become the largest ophthalmology stem cell study registered at the National Institutes of Health to date (www.clinicaltrials.gov Identifier NCT 01920867). SCOTS utilizes autologous bone marrow-derived stem cells (BMSCs) for treatment of retinal and optic nerve diseases. Pre-treatment and post-treatment comprehensive eye exams of a 54 year old female patient were performed both at the Florida Study Center, USA and at The Eye Center of Columbus, USA. As a consequence of a relapsing optic neuritis, the patient's previously normal visual acuity decreased to between 20/350 and 20/400 in the right eye and to 20/70 in the left eye. Significant visual field loss developed bilaterally. The patient underwent a right eye vitrectomy with injection of BMSCs into the optic nerve of the right eyeand retrobulbar, subtenon and intravitreal injection of BMSCs in the left eye. At 15 months after SCOTS treatment, the patient's visual acuity had improved to 20/150 in the right eye and 20/20 in the left eye. Bilateral visual fields improved markedly. Both macular thickness and fast retinal nerve fiber layer thickness were maximally improved at 3 and 6 months after SCOTS treatment. The patient also reduced her mycophenylate dose from 1,500 mg per day to 500 mg per day and required no steroid pulse therapy during the 15-month follow up.

  10. Difficulties of attribution of effect in workers exposed to fiberglass and asbestos.

    PubMed

    Kilburn, K H; Warshaw, R H

    1991-01-01

    Man-made mineral fibers have many properties of asbestos that raise concern about their safety. We studied 175 fiberglass production workers, using chest radiographs, measurement of total lung capacity, chest examinations, and occupational and medical histories. Pulmonary volumes and flows were calculated as percent of predicted, adjusted for height, age, ethnicity, and cigarette smoking. Thirty-one men with radiographically evident small irregular opacities of profusion of 1/0 or greater and/or pleural abnormalities were observed. Eight of 38 men with such changes said they had been exposed only to fiberglass; the other 23 with radiologically detectable pleural and/or pulmonary changes were among the 137 whose histories indicated that they had been exposed to asbestos and to fiberglass. Pulmonary function measurements as group means were reduced in the 175: FVC was 94.8% predicted, FEV1 was 91.3% predicted, FEF25-75 was 80.7% predicted, FEF75-85 was 73.1% predicted and FEV1/FVC was 0.73. Total lung capacity (TLC) was elevated to 114.2% predicted (mean) and RV/TLC (mean 0.46) was also elevated. Although only 78% of fiberglass production workers gave histories of asbestos exposure, all had shared the air in a manufacturing plant where ovens insulated with asbestos were continuously cleaned, repaired, dismantled, and rebuilt. It appears that attribution of the effects of their exposure to fiberglass could not be estimated independently of the effects of asbestos exposure.

  11. Pulmonary effects of exposure to fine fibreglass: irregular opacities and small airways obstruction.

    PubMed Central

    Kilburn, K H; Powers, D; Warshaw, R H

    1992-01-01

    OBJECTIVE--Man made mineral fibres imitate asbestos and produce tumours of the pleura in animals. To answer the question, Does prolonged exposure to fibreglass adversely affect pulmonary function or produce radiographic abnormalities in human subjects? we studied workers in a midwestern appliance plant where refrigerator doors and previously entire cabinets were insulated with fibreglass sheeting and loose rotary spun fibreglass. METHODS--Spirometry and lung volumes were measured, respiratory and occupational questionnaires were administered, and chest x-ray films were read for pneumoconiosis using International Labour Office (ILO) 1980 criteria in 284 workers with exposure of 20 years or more. RESULTS--Expiratory flows were reduced including FEV1 (mean 90.3% of predicted (pr), FEF25-75 (85.5% pr), and FEF75-85 (76.2% pr). Forced vital capacity was significantly reduced (92.8% pr) and total lung capacity was significantly increased (109.2% pr). In white male smokers, a group large enough for comparisons, parameters of pulmonary function were reduced further in the presence of irregular opacities. Forty three workers (15.1%) had evidence of pneumoconiosis on chest radiographs: 26 of these (9.1%), had no known exposure to asbestos and 17 (6.0%) had some exposure. The best judgement was that in 36 (13.0%), pulmonary opacities or pleural abnormalities were due to fibreglass. CONCLUSION--Commercial rotary spun fibreglass used for insulating appliances appears to produce human disease that is similar to asbestosis. PMID:1419860

  12. Respiratory damage in children exposed to urban pollution.

    PubMed

    Calderón-Garcidueñas, Lilian; Mora-Tiscareño, Antonieta; Fordham, Lynn A; Valencia-Salazar, Gildardo; Chung, Charles J; Rodriguez-Alcaraz, Antonio; Paredes, Rogelio; Variakojis, Daina; Villarreal-Calderón, Anna; Flores-Camacho, Lourdes; Antunez-Solis, Angelina; Henríquez-Roldán, Carlos; Hazucha, Milan J

    2003-08-01

    Southwest Metropolitan Mexico City (SWMMC) children are chronically exposed to complex mixtures of air pollutants. In a cross-sectional arm of our study, we investigated the association between exposure to SWMMC atmosphere and nasal abnormalities, hyperinflation, and interstitial markings assessed by chest X-rays, lung function changes, several serum cytokines, and endothelin-1 in 174 children aged 5-17 years vs. 27 control children residents in low-polluted areas. Control children had no nasal lesions, and only one child showed an abnormal chest X-ray. SWMMC children exhibited nasal abnormalities (22%), hyperinflation (67%), interstitial markings (49%), and a mild restrictive pattern by spirometry (10%). Interstitial markings were associated with a decrease in predicted values of FEF(25-75), FEF(75), and the FEV(1)/FVC ratio. Boys had a higher probability of developing interstitial markings with age (P = 0.004). Blood smear findings included toxic granulations in neutrophils and schistocytes. SWMMC children had more serum IL10 and IL6 and less IL8 than controls. In a longitudinal arm of our study, we found a significant seasonal drop in FVC and FEV(1) associated with a 6-month period of high ozone and PM(10) levels. Our data strongly suggest that a lifelong exposure to urban air pollution causes respiratory damage in children. Moreover, a cytokine network becomes imbalanced, with a shift towards upregulation of anti-inflammatory cytokines. Consequently, these children are potentially at risk for developing chronic lung disease and other systemic effects later in life. Copyright 2003 Wiley-Liss, Inc.

  13. Acting without seeing: eye movements reveal visual processing without awareness.

    PubMed

    Spering, Miriam; Carrasco, Marisa

    2015-04-01

    Visual perception and eye movements are considered to be tightly linked. Diverse fields, ranging from developmental psychology to computer science, utilize eye tracking to measure visual perception. However, this prevailing view has been challenged by recent behavioral studies. Here, we review converging evidence revealing dissociations between the contents of perceptual awareness and different types of eye movement. Such dissociations reveal situations in which eye movements are sensitive to particular visual features that fail to modulate perceptual reports. We also discuss neurophysiological, neuroimaging, and clinical studies supporting the role of subcortical pathways for visual processing without awareness. Our review links awareness to perceptual-eye movement dissociations and furthers our understanding of the brain pathways underlying vision and movement with and without awareness. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Acting without seeing: Eye movements reveal visual processing without awareness Miriam Spering & Marisa Carrasco

    PubMed Central

    Spering, Miriam; Carrasco, Marisa

    2015-01-01

    Visual perception and eye movements are considered to be tightly linked. Diverse fields, ranging from developmental psychology to computer science, utilize eye tracking to measure visual perception. However, this prevailing view has been challenged by recent behavioral studies. We review converging evidence revealing dissociations between the contents of perceptual awareness and different types of eye movements. Such dissociations reveal situations in which eye movements are sensitive to particular visual features that fail to modulate perceptual reports. We also discuss neurophysiological, neuroimaging and clinical studies supporting the role of subcortical pathways for visual processing without awareness. Our review links awareness to perceptual-eye movement dissociations and furthers our understanding of the brain pathways underlying vision and movement with and without awareness. PMID:25765322

  15. Treatment planning systems for external whole brain radiation therapy: With and without MLC (multi leaf collimator) optimization

    NASA Astrophysics Data System (ADS)

    Budiyono, T.; Budi, W. S.; Hidayanto, E.

    2016-03-01

    Radiation therapy for brain malignancy is done by giving a dose of radiation to a whole volume of the brain (WBRT) followed by a booster at the primary tumor with more advanced techniques. Two external radiation fields given from the right and left side. Because the shape of the head, there will be an unavoidable hotspot radiation dose of greater than 107%. This study aims to optimize planning of radiation therapy using field in field multi-leaf collimator technique. A study of 15 WBRT samples with CT slices is done by adding some segments of radiation in each field of radiation and delivering appropriate dose weighting using a TPS precise plan Elekta R 2.15. Results showed that this optimization a more homogeneous radiation on CTV target volume, lower dose in healthy tissue, and reduced hotspots in CTV target volume. Comparison results of field in field multi segmented MLC technique with standard conventional technique for WBRT are: higher average minimum dose (77.25% ± 0:47%) vs (60% ± 3:35%); lower average maximum dose (110.27% ± 0.26%) vs (114.53% ± 1.56%); lower hotspot volume (5.71% vs 27.43%); and lower dose on eye lenses (right eye: 9.52% vs 18.20%); (left eye: 8.60% vs 16.53%).

  16. Wide field-of-view bifocal eyeglasses

    NASA Astrophysics Data System (ADS)

    Barbero, Sergio; Rubinstein, Jacob

    2015-09-01

    When vision is affected simultaneously by presbyopia and myopia or hyperopia, a solution based on eyeglasses implies a surface with either segmented focal regions (e.g. bifocal lenses) or a progressive addition profile (PALs). However, both options have the drawback of reducing the field-of-view for each power position, which restricts the natural eye-head movements of the wearer. To avoid this serious limitation we propose a new solution which is essentially a bifocal power-adjustable optical design ensuring a wide field-of-view for every viewing distance. The optical system is based on the Alvarez principle. Spherical refraction correction is considered for different eccentric gaze directions covering a field-of-view range up to 45degrees. Eye movements during convergence for near objects are included. We designed three bifocal systems. The first one provides 3 D for far vision (myopic eye) and -1 D for near vision (+2 D Addition). The second one provides a +3 D addition with 3 D for far vision. Finally the last system is an example of reading glasses with +1 D power Addition.

  17. Investigating the usefulness of a cluster-based trend analysis to detect visual field progression in patients with open-angle glaucoma.

    PubMed

    Aoki, Shuichiro; Murata, Hiroshi; Fujino, Yuri; Matsuura, Masato; Miki, Atsuya; Tanito, Masaki; Mizoue, Shiro; Mori, Kazuhiko; Suzuki, Katsuyoshi; Yamashita, Takehiro; Kashiwagi, Kenji; Hirasawa, Kazunori; Shoji, Nobuyuki; Asaoka, Ryo

    2017-12-01

    To investigate the usefulness of the Octopus (Haag-Streit) EyeSuite's cluster trend analysis in glaucoma. Ten visual fields (VFs) with the Humphrey Field Analyzer (Carl Zeiss Meditec), spanning 7.7 years on average were obtained from 728 eyes of 475 primary open angle glaucoma patients. Mean total deviation (mTD) trend analysis and EyeSuite's cluster trend analysis were performed on various series of VFs (from 1st to 10th: VF1-10 to 6th to 10th: VF6-10). The results of the cluster-based trend analysis, based on different lengths of VF series, were compared against mTD trend analysis. Cluster-based trend analysis and mTD trend analysis results were significantly associated in all clusters and with all lengths of VF series. Between 21.2% and 45.9% (depending on VF series length and location) of clusters were deemed to progress when the mTD trend analysis suggested no progression. On the other hand, 4.8% of eyes were observed to progress using the mTD trend analysis when cluster trend analysis suggested no progression in any two (or more) clusters. Whole field trend analysis can miss local VF progression. Cluster trend analysis appears as robust as mTD trend analysis and useful to assess both sectorial and whole field progression. Cluster-based trend analyses, in particular the definition of two or more progressing cluster, may help clinicians to detect glaucomatous progression in a timelier manner than using a whole field trend analysis, without significantly compromising specificity. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  18. Emerging applications of eye-tracking technology in dermatology.

    PubMed

    John, Kevin K; Jensen, Jakob D; King, Andy J; Pokharel, Manusheela; Grossman, Douglas

    2018-04-06

    Eye-tracking technology has been used within a multitude of disciplines to provide data linking eye movements to visual processing of various stimuli (i.e., x-rays, situational positioning, printed information, and warnings). Despite the benefits provided by eye-tracking in allowing for the identification and quantification of visual attention, the discipline of dermatology has yet to see broad application of the technology. Notwithstanding dermatologists' heavy reliance upon visual patterns and cues to discriminate between benign and atypical nevi, literature that applies eye-tracking to the study of dermatology is sparse; and literature specific to patient-initiated behaviors, such as skin self-examination (SSE), is largely non-existent. The current article provides a review of eye-tracking research in various medical fields, culminating in a discussion of current applications and advantages of eye-tracking for dermatology research. Copyright © 2018 Japanese Society for Investigative Dermatology. Published by Elsevier B.V. All rights reserved.

  19. Eye movement identification based on accumulated time feature

    NASA Astrophysics Data System (ADS)

    Guo, Baobao; Wu, Qiang; Sun, Jiande; Yan, Hua

    2017-06-01

    Eye movement is a new kind of feature for biometrical recognition, it has many advantages compared with other features such as fingerprint, face, and iris. It is not only a sort of static characteristics, but also a combination of brain activity and muscle behavior, which makes it effective to prevent spoofing attack. In addition, eye movements can be incorporated with faces, iris and other features recorded from the face region into multimode systems. In this paper, we do an exploring study on eye movement identification based on the eye movement datasets provided by Komogortsev et al. in 2011 with different classification methods. The time of saccade and fixation are extracted from the eye movement data as the eye movement features. Furthermore, the performance analysis was conducted on different classification methods such as the BP, RBF, ELMAN and SVM in order to provide a reference to the future research in this field.

  20. [Clinical feature of chronic compressive optic neuropathy without optic atrophy].

    PubMed

    Jiang, Libin; Shi, Jitong; Liu, Wendong; Kang, Jun; Wang, Ningli

    2014-12-01

    To investigate the clinical feature of the chronic compressive optic neuropathy without optic atrophy. Retrospective cases series study. The clinical data of 25 patients (37 eyes) with chronic compressive optic neuropathy without optic atrophy, treated in Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, from October, 2005 to March, 2014, were collected. Those patients had been showing visual symptoms for 6 months or longer, but missed diagnosed or misdiagnosed as other eye diseases due to their normal or slightly changed fundi. The collected data including visual acuities, visual fields, neuroimaging and/or pathologic diagnosis were analyzed. Among the 25 patients, there were 5 males and 20 females, and their ages range from 9 to 74 years [average (47.5 ± 13.4) years]. All patients suffered progressive impaired vision in single eye or both eyes, without exophthalmos or abnormal eye movements. Except one patient had a headache, other patients did not show systemic symptoms. The corrected visual acuities were between HM to 1.0, and their appearances of optic discs and colors of fundi were normal. After neuroimaging and/or pathological examination, it was proven that 14 patients suffered tuberculum sellae meningiomas, 5 patients with hypophysoma, 3 patient with optic nerve sheath meningioma in orbital apex, 1 patient with cavernous hemangioma, 1 patient with vascular malformation in orbital apex and 1 patient with optic nerve glioma. Among the 19 patients whose suffered occupied lesions of saddle area, 14 patients underwent visual field examinations, and only 4 patients showed classic visual field defects caused by optic chiasmal lesions. Occult progressive visual loss was the most important clinical feature of the disease.