HUMAN EYE OPTICS: Determination of positions of optical elements of the human eye
NASA Astrophysics Data System (ADS)
Galetskii, S. O.; Cherezova, T. Yu
2009-02-01
An original method for noninvasive determining the positions of elements of intraocular optics is proposed. The analytic dependence of the measurement error on the optical-scheme parameters and the restriction in distance from the element being measured are determined within the framework of the method proposed. It is shown that the method can be efficiently used for determining the position of elements in the classical Gullstrand eye model and personalised eye models. The positions of six optical surfaces of the Gullstrand eye model and four optical surfaces of the personalised eye model can be determined with an error of less than 0.25 mm.
Hadjidimitrakis, K; Moschovakis, A K; Dalezios, Y; Grantyn, A
2007-05-01
Rapid gaze shifts are often accomplished with coordinated movements of the eyes and head, the relative amplitude of which depends on the starting position of the eyes. The size of gaze shifts is determined by the superior colliculus (SC) but additional processing in the lower brain stem is needed to determine the relative contributions of eye and head components. Models of eye-head coordination often assume that the strength of the command sent to the head controllers is modified by a signal indicative of the eye position. Evidence in favor of this hypothesis has been recently obtained in a study of phasic electromyographic (EMG) responses to stimulation of the SC in head-restrained monkeys (Corneil et al. in J Neurophysiol 88:2000-2018, 2002b). Bearing in mind that the patterns of eye-head coordination are not the same in all species and because the eye position sensitivity of phasic EMG responses has not been systematically investigated in cats, in the present study we used cats to address this issue. We stimulated electrically the intermediate and deep layers of the caudal SC in alert cats and recorded the EMG responses of neck muscles with horizontal and vertical pulling directions. Our data demonstrate that phasic, short latency EMG responses can be modulated by the eye position such that they increase as the eye occupies more and more eccentric positions in the pulling direction of the muscle tested. However, the influence of the eye position is rather modest, typically accounting for only 10-50% of the variance of EMG response amplitude. Responses evoked from several SC sites were not modulated by the eye position.
Viewing condition dependence of the gaze-evoked nystagmus in Arnold Chiari type 1 malformation.
Ghasia, Fatema F; Gulati, Deepak; Westbrook, Edward L; Shaikh, Aasef G
2014-04-15
Saccadic eye movements rapidly shift gaze to the target of interest. Once the eyes reach a given target, the brainstem ocular motor integrator utilizes feedback from various sources to assure steady gaze. One of such sources is cerebellum whose lesion can impair neural integration leading to gaze-evoked nystagmus. The gaze evoked nystagmus is characterized by drifts moving the eyes away from the target and a null position where the drifts are absent. The extent of impairment in the neural integration for two opposite eccentricities might determine the location of the null position. Eye in the orbit position might also determine the location of the null. We report this phenomenon in a patient with Arnold Chiari type 1 malformation who had intermittent esotropia and horizontal gaze-evoked nystagmus with a shift in the null position. During binocular viewing, the null was shifted to the right. During monocular viewing, when the eye under cover drifted nasally (secondary to the esotropia), the null of the gaze-evoked nystagmus reorganized toward the center. We speculate that the output of the neural integrator is altered from the bilateral conflicting eye in the orbit position secondary to the strabismus. This could possibly explain the reorganization of the location of the null position. Copyright © 2014 Elsevier B.V. All rights reserved.
Ocular Vestibular Evoked Myogenic Potentials in Response to Three Test Positions and Two Frequencies
Todai, Janvi K.; Congdon, Sharon L.; Sangi-Haghpeykar, Haleh; Cohen, Helen S.
2014-01-01
Objective To determine how eye closure, test positions, and stimulus frequencies influence ocular vestibular evoked myogenic potentials. Study Design This study used a within-subjects repeated measures design. Methods Twenty asymptomatic subjects were each tested on ocular vestibular evoked myogenic potentials in three head/eye conditions at 500 Hz and 1000 Hz using air-conducted sound: 1) Sitting upright, head erect, eyes open, looking up. 2) Lying supine, neck flexed 30 degrees, eyes open and looking up. 3) Lying supine, neck flexed 30 degrees, eyes closed and relaxed. Four dependent variables measured were n10, p16, amplitude, and threshold. Results The supine position/ eyes open was comparable to sitting/ eyes open and better than supine/ eyes closed. Eyes closed resulted in lower amplitude, higher threshold, and prolonged latency. Significantly fewer subjects provided responses with eyes closed than with eyes open. No significant differences were found between both eyes open conditions. Both n10 and p16 were lower at 1000 Hz than at 500 Hz. Amplitude and threshold were higher at 1000 Hz than at 500 Hz. Conclusion Supine eyes open is a reliable alternative to sitting eyes open in patients who cannot maintain a seated position. Testing at 1000 Hz provides a larger response with a faster onset that fatigues faster than at 500 Hz. The increased variability and decreased response in the eyes closed position suggest that the eyes closed position is not reliable. PMID:24178911
Peripheral Refraction, Peripheral Eye Length, and Retinal Shape in Myopia.
Verkicharla, Pavan K; Suheimat, Marwan; Schmid, Katrina L; Atchison, David A
2016-09-01
To investigate how peripheral refraction and peripheral eye length are related to retinal shape. Relative peripheral refraction (RPR) and relative peripheral eye length (RPEL) were determined in 36 young adults (M +0.75D to -5.25D) along horizontal and vertical visual field meridians out to ±35° and ±30°, respectively. Retinal shape was determined in terms of vertex radius of curvature Rv, asphericity Q, and equivalent radius of curvature REq using a partial coherence interferometry method involving peripheral eye lengths and model eye raytracing. Second-order polynomial fits were applied to RPR and RPEL as functions of visual field position. Linear regressions were determined for the fits' second order coefficients and for retinal shape estimates as functions of central spherical refraction. Linear regressions investigated relationships of RPR and RPEL with retinal shape estimates. Peripheral refraction, peripheral eye lengths, and retinal shapes were significantly affected by meridian and refraction. More positive (hyperopic) relative peripheral refraction, more negative RPELs, and steeper retinas were found along the horizontal than along the vertical meridian and in myopes than in emmetropes. RPR and RPEL, as represented by their second-order fit coefficients, correlated significantly with retinal shape represented by REq. Effects of meridian and refraction on RPR and RPEL patterns are consistent with effects on retinal shape. Patterns derived from one of these predict the others: more positive (hyperopic) RPR predicts more negative RPEL and steeper retinas, more negative RPEL predicts more positive relative peripheral refraction and steeper retinas, and steeper retinas derived from peripheral eye lengths predict more positive RPR.
Romano, Paul E
2006-01-01
The HR (prism diopters [PD] per mm of corneal light reflection test [CLRT] asymmetry for strabometry) varies in humans from 14 to 24 PD/mm, but is totally unpredictable. Photo(grammetric) HR calibration in (of) each case facilitates acceptable strabometry precision and accuracy. Take 3 flash photos of the patient with both the preferred eye and then the deviating eye fixating straight ahead and then again with the deviation eye fixing at (+/-5-10 PD) the strabismic angle on a metric rule (stick) one meter away from the camera lens (where 1 cm = 1 PD). On these 3 photos, make four precise measurements of the position of the CLR with reference to the limbus: In the deviating eye fixing straight ahead and fixating at the angle of deviation. Divide the mm difference in location into the change in the angle of fixation to determine the HR for this patient at this angle. Then determine the CLR position in both the deviating eye and the fixing eye in the straight ahead primary position picture. Apply the calculated calibrated HR to the asymmetry of the CLRs in primary position to determine the true strabismic deviation. This imaging method insures accurate Hirschberg CLRT strabometry in each case, determining the deviation in "free space", under conditions of normal binocular viewing, uncontaminated by the artifacts or inaccuracies of other conventional strabometric methods or devices. So performed, the Hirschberg CLRT is the gold standard of strabometry.
Clinical Verification of Image Warping as a Potential Aid for the Visually Handicapped
NASA Technical Reports Server (NTRS)
Loshin, David
1996-01-01
The bulk of this research was to designed determine potential of the Programmable Remapper (PR) as a device to enhance vision for the visually handicapped. This research indicated that remapping would have potential as a low vision device if the eye position could be monitored with feedback to specify the proper location of the remapped image. This must be accomplished at high rate so that there is no lag of the image behind the eye position. Since at this time, there is no portable eye monitor device (at a reasonable cost) that will operate under the required conditions, it would not be feasible to continue with remapping experiments for patients with central field defects. However, since patients with peripheral field defects do not have the same eye positioning requirements, they may indeed benefit from this technology. Further investigations must be performed to determine plausibility of this application of remapping.
Ocular surface changes in thyroid eye disease.
Ismailova, Dilyara S; Fedorov, Anatoly A; Grusha, Yaroslav O
2013-04-01
To study the incidence and risk factors of ocular surface damage in thyroid eye disease (TED) and to determine histological changes underlying positive vital staining in this condition. Forty-six patients (92 eyes) with TED were included in this study. Routine ophthalmologic examination, Schirmer test I, vital staining and corneal sensitivity were performed. Fifteen patients with positive vital staining underwent impression cytology and incisional biopsy. Positive vital staining with lissamine green was observed in 56 eyes (60.9%), 30 patients (65.2%). The average degree of staining was 4.57 ± 0.44 (National Eye Institute Workshop grading system). Severe dry eye syndrome was found in 16%. The following histological changes of conjunctiva were revealed: significant epithelial dystrophy with cell polymorphism, goblet cells loss, excessive desquamation and epithelial keratinization with local leukocytic infiltration of substantia propria. According to our results dry eye syndrome is present in 65.2% of patients (60.9% eyes) with TED. Significant risk factors of ocular surface damage in TED were exophthalmos, lagophthalmos, palpebral fissure height and lower lid retraction. Positive conjunctival staining results from punctuate epithelial erosions and excessive desquamation of superficial cells. Histopathologic changes detected in conjunctiva consistent with dry eye and are not specific for TED.
[Virtual reality in ophthalmological education].
Wagner, C; Schill, M; Hennen, M; Männer, R; Jendritza, B; Knorz, M C; Bender, H J
2001-04-01
We present a computer-based medical training workstation for the simulation of intraocular eye surgery. The surgeon manipulates two original instruments inside a mechanical model of the eye. The instrument positions are tracked by CCD cameras and monitored by a PC which renders the scenery using a computer-graphic model of the eye and the instruments. The simulator incorporates a model of the operation table, a mechanical eye, three CCD cameras for the position tracking, the stereo display, and a computer. The three cameras are mounted under the operation table from where they can observe the interior of the mechanical eye. Using small markers the cameras recognize the instruments and the eye. Their position and orientation in space is determined by stereoscopic back projection. The simulation runs with more than 20 frames per second and provides a realistic impression of the surgery. It includes the cold light source which can be moved inside the eye and the shadow of the instruments on the retina which is important for navigational purposes.
Common determinants of body size and eye size in chickens from an advanced intercross line.
Prashar, Ankush; Hocking, Paul M; Erichsen, Jonathan T; Fan, Qiao; Saw, Seang Mei; Guggenheim, Jeremy A
2009-06-15
Myopia development is characterised by an increased axial eye length. Therefore, identifying factors that influence eye size may provide new insights into the aetiology of myopia. In humans, axial length is positively correlated to height and weight, and in mice, eye weight is positively correlated with body weight. The purpose of this study was to examine the relationship between eye size and body size in chickens from a genetic cross in which alleles with major effects on eye and body size were segregating. Chickens from a cross between a layer line (small body size and eye size) and a broiler line (large body and eye size) were interbred for 10 generations so that alleles for eye and body size would have the chance to segregate independently. At 3 weeks of age, 510 chicks were assessed using in vivo high resolution A-scan ultrasonography and keratometry. Equatorial eye diameter and eye weight were measured after enucleation. The variations in eye size parameters that could be explained by body weight (BW), body length (BL), head width (HW) and sex were examined using multiple linear regression. It was found that BW, BL and HW and sex together predicted 51-56% of the variation in eye weight, axial length, corneal radius, and equatorial eye diameter. By contrast, the same variables predicted only 22% of the variation in lens thickness. After adjusting for sex, the three body size parameters predicted 45-49% of the variation in eye weight, axial length, corneal radius, and eye diameter, but only 0.4% of the variation in lens thickness. In conclusion, about half of the variation in eye size in the chickens of this broiler-layer advanced intercross line is likely to be determined by pleiotropic genes that also influence body size. Thus, mapping the quantitative trait loci (QTL) that determine body size may be useful in understanding the genetic determination of eye size (a logical inference of this result is that the 20 or more genetic variants that have recently been shown to influence human height may also be found to influence axial eye length). Furthermore, adjusting for body size will be essential in mapping pure eye size QTL in this chicken population, and may also have value in mapping eye size QTL in humans.
Okada, Kouhei; Takai, Shinji; Jin, Denan; Ishida, Osamu; Fukmoto, Masanori; Oku, Hidehiro; Miyazaki, Mizuo; Ikeda, Tsunehiko
2009-01-01
Purpose To determine the effects of mitomycin C (MMC) on the expression of chymase and mast cells in the conjunctival scar after trabeculectomy. Methods Ten eyes of five monkeys were used. Three eyes underwent trabeculectomy with MMC (MMC-treated), four eyes had trabeculectomy without MMC (placebo-treated), and three eyes served as control eyes. Intraocular pressure was measured before and three weeks after surgery. The scores of the degree of conjunctival adhesion were evaluated. Immunohistochemistry was used to analyze the densities of proliferative cell nuclear antigen-positive cells, chymase-positive cells, and mast cells. The ratio of collagen fiber areas to conjunctival and scleral lesions was analyzed by Mallory-Azan staining. Results After trabeculectomy, the intraocular pressure reduction of MMC-treated eyes was significantly different from placebo-treated and control eyes (p=0.032, 0.035). The adhesion score of MMC-treated eyes was also significantly lower than that of placebo-treated eyes (p=0.034). Densities of proliferative cell nuclear antigen-positive cells, chymase-positive cells, and areas of collagen fiber in conjunctival and scleral lesions were significantly decreased in MMC-treated eyes, compared with placebo-treated eyes (p=0.034, 0.034, 0.049, respectively). There was a tendency for the density of mast cells to be suppressed in MMC-treated eyes (p=0.157). Conclusions Chymase might be involved in one of the mechanisms by which MMC suppresses scar formation after trabeculectomy. PMID:19844588
Expansion of visual space during optokinetic afternystagmus (OKAN).
Kaminiarz, André; Krekelberg, Bart; Bremmer, Frank
2008-05-01
The mechanisms underlying visual perceptual stability are usually investigated using voluntary eye movements. In such studies, errors in perceptual stability during saccades and pursuit are commonly interpreted as mismatches between actual eye position and eye-position signals in the brain. The generality of this interpretation could in principle be tested by investigating spatial localization during reflexive eye movements whose kinematics are very similar to those of voluntary eye movements. Accordingly, in this study, we determined mislocalization of flashed visual targets during optokinetic afternystagmus (OKAN). These eye movements are quite unique in that they occur in complete darkness and are generated by subcortical control mechanisms. We found that during horizontal OKAN slow phases, subjects mislocalize targets away from the fovea in the horizontal direction. This corresponds to a perceived expansion of visual space and is unlike mislocalization found for any other voluntary or reflexive eye movement. Around the OKAN fast phases, we found a bias in the direction of the fast phase prior to its onset and opposite to the fast-phase direction thereafter. Such a biphasic modulation has also been reported in the temporal vicinity of saccades and during optokinetic nystagmus (OKN). A direct comparison, however, showed that the modulation during OKAN was much larger and occurred earlier relative to fast-phase onset than during OKN. A simple mismatch between the current eye position and the eye-position signal in the brain is unlikely to explain such disparate results across similar eye movements. Instead, these data support the view that mislocalization arises from errors in eye-centered position information.
Bayesian microsaccade detection
Mihali, Andra; van Opheusden, Bas; Ma, Wei Ji
2017-01-01
Microsaccades are high-velocity fixational eye movements, with special roles in perception and cognition. The default microsaccade detection method is to determine when the smoothed eye velocity exceeds a threshold. We have developed a new method, Bayesian microsaccade detection (BMD), which performs inference based on a simple statistical model of eye positions. In this model, a hidden state variable changes between drift and microsaccade states at random times. The eye position is a biased random walk with different velocity distributions for each state. BMD generates samples from the posterior probability distribution over the eye state time series given the eye position time series. Applied to simulated data, BMD recovers the “true” microsaccades with fewer errors than alternative algorithms, especially at high noise. Applied to EyeLink eye tracker data, BMD detects almost all the microsaccades detected by the default method, but also apparent microsaccades embedded in high noise—although these can also be interpreted as false positives. Next we apply the algorithms to data collected with a Dual Purkinje Image eye tracker, whose higher precision justifies defining the inferred microsaccades as ground truth. When we add artificial measurement noise, the inferences of all algorithms degrade; however, at noise levels comparable to EyeLink data, BMD recovers the “true” microsaccades with 54% fewer errors than the default algorithm. Though unsuitable for online detection, BMD has other advantages: It returns probabilities rather than binary judgments, and it can be straightforwardly adapted as the generative model is refined. We make our algorithm available as a software package. PMID:28114483
Holloway, Edith E; Sturrock, Bonnie A; Lamoureux, Ecosse L; Keeffe, Jill E; Rees, Gwyneth
2015-12-01
To investigate characteristics associated with screening positive for depressive symptoms among older adults accessing low-vision rehabilitation and eye-care services and to determine client acceptability of depression screening using the Patient Health Questionnaire-2 (PHQ-2) in these settings. One-hundred and twenty-four older adults (mean = 77.02 years, SD = 9.12) attending low-vision rehabilitation and eye-care services across Australia were screened for depression and invited to complete a telephone-administered questionnaire to determine characteristics associated with depressive symptoms and client acceptability of screening in these settings. Thirty-seven per cent (n = 46/124) of participants screened positive for depressive symptoms, and the majority considered the new depression screening method to be a 'good idea' in vision services (85%). Severe vision loss (<6/60 in the better eye) was associated with an increased odds of screening positive for depressive symptoms (odds ratio 2.37; 95% confidence interval 1.08-6.70) even after adjusting for potential confounders. Participants who screened positive had a preference for 'talking' therapy or a combination of medication and 'talking therapy' delivered within their own home (73%) or via telephone (67%). The PHQ-2 appears to be an acceptable method for depression screening in eye-care settings among older adults. Targeted interventions that incorporate home-based or telephone delivered therapy sessions may improve outcomes for depression in this group. © 2014 ACOTA.
Non-Orthogonal Corneal Astigmatism among Normal and Keratoconic Brazilian and Chinese populations.
Abass, Ahmed; Clamp, John; Bao, FangJun; Ambrósio, Renato; Elsheikh, Ahmed
2018-06-01
To investigate the prevalence of non-orthogonal astigmatism among normal and keratoconic Brazilian and Chinese populations. Topography data were obtained using the Pentacam High Resolution (HR) system ® from 458 Brazilian (aged 35.6 ± 15.8 years) and 505 Chinese (aged 31.6 ± 10.8 years) eyes with no history of keratoconus or refractive surgery, and 314 Brazilian (aged 24.2 ± 5.7 years) and 74 Chinese (aged 22.0 ± 5.5 years) keratoconic eyes. Orthogonal values of optical flat and steep powers were determined by finding the angular positions of two perpendicular meridians that gave the maximum difference in power. Additionally, the angular positions of the meridians with the minimum and maximum optical powers were located while being unrestricted by the usual orthogonality assumption. Eyes were determined to have non-orthogonal astigmatism if the angle between the two meridians with maximum and minimum optical power deviated by more than 5° from 90°. Evidence of non-orthogonal astigmatism was found in 39% of the Brazilian keratoconic eyes, 26% of the Chinese keratoconic eyes, 29% of the Brazilian normal eyes and 20% of the Chinese normal eyes. The large percentage of participants with non-orthogonal astigmatism in both normal and keratoconic eyes illustrates the need for the common orthogonality assumption to be reviewed when correcting for astigmatism. The prevalence of non-orthogonality should be considered by expanding the prescription system to consider the two power meridians and their independent positions.
Binocular lens tilt and decentration measurements in healthy subjects with phakic eyes.
Schaeffel, Frank
2008-05-01
Tilt and decentration of the natural crystalline lens affect optical quality of the foveal image. However, little is known about the distributions of these variables in healthy subjects with phakic eyes and about their correlations in both eyes. A simple, portable, easy-to-use, and partially automated device was developed to study lens tilt and decentration in both eyes of 11 healthy subjects with phakic eyes. The first, third, and fourth Purkinje images (P1, P3, P4) were visualized using a single infrared (IR) light-emitting diode (LED), a planar lens (F = 85 mm; f/number of 1.4), and an infrared sensitive analog video camera. Software was developed to mark pupil edges and positions of P1, P4, and P3 with the cursor of the computer mouse, for three different gaze positions, and an automated regression analysis determined the gaze position that superimposed the third and fourth Purkinje images, the gaze direction for which the lens was oriented perpendicularly to the axis of the IR LED. In this position, lens decentration was determined as the linear distance of the superimposed P3/P4 positions from the pupil center. Contrary to previous approaches, a short initial fixation of a green LED with known angular position calibrated the device as a gaze tracker, and no further positional information was necessary on fixation targets. Horizontal and vertical kappa, horizontal and vertical lens tilt, and vertical lens decentration were highly correlated in both eyes of the subjects, whereas horizontal decentration of the lens was not. There was a large variability of kappa (average horizontal kappa -1.63 degrees +/- 1.77 degrees [left eyes] and +2.07 degrees +/- 2.68 degrees [right eyes]; average vertical kappa +2.52 degrees +/- 1.30 degrees [left eyes] and +2.77 degrees +/- 1.65 degrees [right eyes]). Standard deviation from three repeated measurements ranged from 0.28 degrees to 0.51 degrees for kappa, 0.36 degrees to 0.91 degrees for horizontal lens tilt, and 0.36 degrees to 0.48 degrees for vertical lens tilt. Decentration was measured with standard deviations ranging from 0.02 mm to 0.05 mm. All lenses were found tilted to the temporal side with respect to the fixation axis (on average by 4.6 degrees ). They were also decentered downward with respect to the pupil center by approximately 0.3 mm. Lens tilts and positions could be conveniently measured with the described portable device, a video camera with a large lens. That the lenses were tilted to the temporal side in both eyes, even if corrected for kappa, was unexpected. That they were displaced downward with respect to the pupil center could be related to gravity.
Trattler, William B; Majmudar, Parag A; Donnenfeld, Eric D; McDonald, Marguerite B; Stonecipher, Karl G; Goldberg, Damien F
2017-01-01
Purpose To determine the incidence and severity of dry eye as determined by the International Task Force (ITF) scale in patients being screened for cataract surgery. Patients and methods This was a prospective, multi-center, observational study of 136 patients, at least 55 years of age, who were scheduled to undergo cataract surgery. The primary outcome measure was the incidence of dry eye as evaluated by grade on the ITF scale and secondary outcome measures include tear break-up time (TBUT), ocular surface disease index score, corneal staining with fluorescein, conjunctival staining with lissamine green, and a patient questionnaire to evaluate symptoms of dry eye. Results Mean patient age was 70.7 years. A total of 73.5% of patients were Caucasian and 50% were female. Almost 60% had never complained of a foreign body sensation; only 13% complained of a foreign body sensation half or most of the time. The majority of patients (62.9%) had a TBUT ≤5 seconds, 77% of eyes had positive corneal staining and 50% of the eyes had positive central corneal staining. Eighteen percent had Schirmer’s score with anesthesia ≤5 mm. Conclusion The incidence of dry eye in patients scheduled to undergo cataract surgery in a real-world setting is higher than anticipated. PMID:28848324
Head-body righting reflex from the supine position and preparatory eye movements.
Troiani, Diana; Ferraresi, Aldo; Manni, Ermanno
2005-05-01
Saccular and utricular maculae can provide information on the supine static position, considering that both have pronounced curved structures with hair cells having a variety of polarization vectors that enable them to sense an inverted position and thus direct the righting reflex. The vestibular system is essential for the structuring of motor behaviour, senses linear and angular acceleration and has a strong influence on posture and balance at rest, during locomotion and in head body righting reflexes. Using guinea pigs in the supine position with a symmetrical head and trunk position, the ocular position was analysed to ascertain whether any ocular movement that occurred would adopt a spatial deviation indicative of the subsequent head and body righting. The characteristics of the righting reflex (direction, latency, duration and velocity) were analysed in guinea pigs from position signals obtained from search coils implanted in the eye, head and pelvis. The animals were kept in a supine position for a few seconds or even minutes with the eyes in a stable primary position and the head and body symmetrical and immobile. The righting reflex took place either immediately or after a slow deviation of the eyes. In both cases the righting sequence (eyes, head, body) was stereotyped and consistent. The direction of head and body righting was along the longitudinal axis of the animal and was either clockwise or anticlockwise and the direction of righting was related to the direction of the eye deviation. The ocular deviation and the direction of deviation that initiated and determined the direction of the righting reflex could be explained by possible otolithic activation.
Utility of Novel Autoantibodies in the Diagnosis of Sjögren's Syndrome Among Patients With Dry Eye.
Karakus, Sezen; Baer, Alan N; Agrawal, Devika; Gurakar, Merve; Massof, Robert W; Akpek, Esen K
2018-04-01
To investigate the value of 3 novel autoantibodies [salivary protein 1 (SP1), carbonic anhydrase 6 (CA6), and parotid secretory protein (PSP)] in differentiating Sjögren's syndrome (SS)-related dry eye from non-SS dry eye. Forty-six dry eye patients with SS (SS dry eye), 14 dry eye patients without SS (non-SS dry eye), and 25 controls were included. The 2012 American College of Rheumatology classification criteria were used for the diagnosis of SS. After a detailed review of systems, the Ocular Surface Disease Index questionnaire, Schirmer test without anesthesia, tear film breakup time, and ocular surface staining were performed to assess dry eye. All participants underwent serological testing using a commercially available finger prick kit. Thirty-seven patients with SS (80.4%) had a positive traditional autoantibody and 28 (60.9%) had a positive novel autoantibody. Traditional autoantibodies were absent in all non-SS dry eye patients and controls. Novel autoantibodies were present in 7/14 (50%) non-SS dry eye patients and 4/25 (16%) controls. Among 3 novel autoantibodies, anti-CA6 was significantly more prevalent in the SS and non-SS dry eye groups than in controls (52.2% vs. 42.9% vs. 8.0%, P = 0.001). Dry eye patients with positive anti-CA6 alone were significantly younger than patients with only traditional autoantibodies. Anti-CA6 was associated with worse dry eye signs and symptoms. Anti-CA6 was the most prevalent novel autoantibody in patients with dry eye, and was associated with younger age and more severe disease. Longitudinal studies are needed to determine whether anti-CA6 is a marker for early SS or perhaps another form of an autoimmune dry eye disease.
NASA Technical Reports Server (NTRS)
Huebner, W. P.; Paloski, W. H.; Reschke, M. F.; Bloomberg, J. J.
1995-01-01
Neglecting the eccentric position of the eyes in the head can lead to erroneous interpretation of ocular motor data, particularly for near targets. We discuss the geometric effects that eye eccentricity has on the processing of target-directed eye and head movement data, and we highlight two approaches to processing and interpreting such data. The first approach involves determining the true position of the target with respect to the location of the eyes in space for evaluating the efficacy of gaze, and it allows calculation of retinal error directly from measured eye, head, and target data. The second approach effectively eliminates eye eccentricity effects by adjusting measured eye movement data to yield equivalent responses relative to a specified reference location (such as the center of head rotation). This latter technique can be used to standardize measured eye movement signals, enabling waveforms collected under different experimental conditions to be directly compared, both with the measured target signals and with each other. Mathematical relationships describing these approaches are presented for horizontal and vertical rotations, for both tangential and circumferential display screens, and efforts are made to describe the sensitivity of parameter variations on the calculated results.
Heo, Hwan; Lee, Won Oh; Shin, Kwang Yong; Park, Kang Ryoung
2014-05-15
We propose a new method for measuring the degree of eyestrain on 3D stereoscopic displays using a glasses-type of eye tracking device. Our study is novel in the following four ways: first, the circular area where a user's gaze position exists is defined based on the calculated gaze position and gaze estimation error. Within this circular area, the position where edge strength is maximized can be detected, and we determine this position as the gaze position that has a higher probability of being the correct one. Based on this gaze point, the eye foveation model is defined. Second, we quantitatively evaluate the correlation between the degree of eyestrain and the causal factors of visual fatigue, such as the degree of change of stereoscopic disparity (CSD), stereoscopic disparity (SD), frame cancellation effect (FCE), and edge component (EC) of the 3D stereoscopic display using the eye foveation model. Third, by comparing the eyestrain in conventional 3D video and experimental 3D sample video, we analyze the characteristics of eyestrain according to various factors and types of 3D video. Fourth, by comparing the eyestrain with or without the compensation of eye saccades movement in 3D video, we analyze the characteristics of eyestrain according to the types of eye movements in 3D video. Experimental results show that the degree of CSD causes more eyestrain than other factors.
NASA Astrophysics Data System (ADS)
Vlachynska, Alzbeta; Oplatkova, Zuzana Kominkova; Sramka, Martin
2017-07-01
The aim of the work is to determine the coordinate system of an eye and insert a polar-axis system into images captured by a slip lamp. The image of the eye with the polar axis helps a surgeon accurately implant toric intraocular lens in the required position/rotation during the cataract surgery. In this paper, two common algorithms for pupil detection are compared: the circle Hough transform and Daugman's algorithm. The procedures were tested and analysed on the anonymous data set of 128 eyes captured at Gemini eye clinic in 2015.
Suzuki, Akira; Matsubara, Kosuke; Sasa, Yuko
2018-04-01
The present study aimed to determine doses delivered to the eye lenses of surgeons while using the inverted-C-arm technique and the protective effect of leaded spectacles during orthopedic surgery. The kerma in air was measured at five positions on leaded glasses positioned near the eye lens and on the neck using small optically stimulated luminescence (OSL) dosemeters. The lens equivalent dose was also measured at the neck using an OSL dosemeter. The maximum equivalent dose to the eye lens and the maximum kerma were 0.8 mSv/month and 0.66 mGy/month, respectively. The leaded glasses reduced the exposure by ~60%. Even if the surgeons are exposed to the maximum dose of X-ray radiation for 5 years, the equivalent doses to the eye lens will not exceed the present limit recommended by the ICRP.
Mian, Shahzad I; Li, Amy Y; Dutta, Satavisha; Musch, David C; Shtein, Roni M
2009-12-01
To determine whether corneal sensation and dry-eye signs and symptoms after myopic laser in situ keratomileusis (LASIK) surgery with a femtosecond laser are affected by varying hinge position, hinge angle, or flap thickness. University-based academic practice, Ann Arbor, Michigan, USA. This prospective randomized contralateral-eye study evaluated eyes after bilateral myopic LASIK with a femtosecond laser (IntraLase). Superior and temporal hinge positions, 45-degree and 90-degree hinge angles, and 100 microm and 130 microm corneal flap thicknesses were compared. Postoperative follow-up at 1 week and 1, 3, 6, and 12 months included central Cochet-Bonnet esthesiometry, the Ocular Surface Disease Index questionnaire, a Schirmer test with anesthesia, tear breakup time (TBUT), corneal fluorescein staining, and conjunctival lissamine green staining. The study evaluated 190 consecutive eyes (95 patients). Corneal sensation was reduced at all postoperative visits, with improvement over 12 months (P<.001). There was no difference in corneal sensation between the different hinge positions, angles, or flap thicknesses at any time point. The overall ocular surface disease index score was increased at 1 week, 1 month, and 3 months (P<.0001, P<.0001, and P = .046, respectively). The percentage of patients with a TBUT longer than 10 seconds was significantly lower at 1 week and 1 month (P<.0001). Dry-eye syndrome after myopic LASIK with a femtosecond laser was mild and improved after 3 months. Corneal flap hinge position, hinge angle, and thickness had no effect on corneal sensation or dry-eye syndrome.
Migliaccio, Americo A; Cremer, Phillip D; Aw, Swee T; Halmagyi, G Michael; Curthoys, Ian S; Minor, Lloyd B; Todd, Michael J
2003-07-01
The aim of this study was to determine whether vergence-mediated changes in the axis of eye rotation in the human vestibulo-ocular reflex (VOR) would obey Listing's Law (normally associated with saccadic eye movements) independent of the initial eye position. We devised a paradigm for disassociating the saccadic velocity axis from eye position by presenting near and far targets that were centered with respect to one eye. We measured binocular 3-dimensional eye movements using search coils in ten normal subjects and 3-dimensional linear head acceleration using Optotrak in seven normal subjects. The stimuli consisted of passive, unpredictable, pitch head rotations with peak acceleration of approximately 2000 degrees /s(2 )and amplitude of approximately 20 degrees. During the pitch head rotation, each subject fixated straight ahead with one eye, whereas the other eye was adducted 4 degrees during far viewing (94 cm) and 25 degrees during near viewing (15 cm). Our data showed expected compensatory pitch rotations in both eyes, and a vergence-mediated horizontal rotation only in the adducting eye. In addition, during near viewing we observed torsional eye rotations not only in the adducting eye but also in the eye looking straight ahead. In the straight-ahead eye, the change in torsional eye velocity between near and far viewing, which began approximately 40 ms after the start of head rotation, was 10+/-6 degrees /s (mean +/- SD). This change in torsional eye velocity resulted in a 2.4+/-1.5 degrees axis tilt toward Listing's plane in that eye. In the adducting eye, the change in torsional eye velocity between near and far viewing was 16+/-6 degrees /s (mean +/- SD) and resulted in a 4.1+/-1.4 degrees axis tilt. The torsional eye velocities were conjugate and both eyes partially obeyed Listing's Law. The axis of eye rotation tilted in the direction of the line of sight by approximately one-third of the angle between the line of sight and a line orthogonal to Listing's plane. This tilt was higher than predicted by the one-quarter rule. The translational acceleration component of the pitch head rotation measured 0.5 g and may have contributed to the increased torsional component observed during near viewing. Our data show that vergence-mediated eye movements obey a VOR/Listing's Law compromise strategy independent of the initial eye position.
Tabernero, Juan; Artal, Pablo
2012-02-01
To determine the optimum position to center a small-aperture corneal inlay and the effect of residual defocus in the surgical eye to maximize depth of focus. Laboratorio de Óptica, Universidad de Murcia, Murcia, Spain. Cohort study. Personalized eye models were built using actual data (corneal topography, eye length, ocular aberrations, and eye alignment). A small aperture 1.6 mm in diameter was placed at the corneal plane in each model. The monochromatic and polychromatic Strehl ratios were calculated as a function of the pinhole position. Different residual defocus values were also incorporated into the models, and the through-focus Strehl ratios were calculated. Sixteen eye models were built. For most subjects, the optimum location of the aperture for distance vision was close to the corneal reflex position. For a given optimized centration of the aperture, the best compromise of depth of focus was obtained when the eyes had some residual myopic defocus (range -0.75 to -1.00 diopter [D]). Strehl ratio values were over 0.1 for far distance, which led to visual acuities better than 20/20. The depth of focus was 2.50 D with a mean near visual acuity of Jaeger 1 or better. In eyes with little astigmatism and aberrations, the optimum centration of the small aperture was near the corneal reflex position. To improve optical outcomes with the inlay, some small residual myopia and correction of corneal astigmatism might be required. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Eye Movements of Patients with Tunnel Vision while Walking
Vargas-Martín, Fernando; Peli, Eli
2006-01-01
Purpose To determine how severe peripheral field loss (PFL) affects the dispersion of eye movements relative to the head, while walking in real environments. This information should help to better define the visual field and clearance requirements for head-mounted mobility visual aids. Methods Eye positions relative to the head were recorded in five retinitis pigmentosa patients with less than 15° of visual field and three normally-sighted people, each walking in varied environments for more than 30 minutes. The eye position recorder was made portable by modifying a head-mounted ISCAN system. Custom data processing was implemented to reject unreliable data. Sample standard deviations of eye position (dispersion) were compared across subject groups and environments. Results PFL patients exhibited narrower horizontal eye position dispersions than normally-sighted subjects (9.4° vs. 14.2°, p < 0.0001) and PFL patients’ vertical dispersions were smaller when walking indoors than outdoors (8.2° vs. 10.3°, p = 0.048). Conclusions When walking, the PFL patients did not increase their scanning eye movements to compensate for missing peripheral vision information. Their horizontal scanning was actually reduced, possibly because saccadic amplitude is limited by a lack of peripheral stimulation. The results suggest that a field-of-view as wide as 40° may be needed for closed (immersive) head-mounted mobility aids, while a much narrower display, perhaps as narrow as 20°, might be sufficient with an open design. PMID:17122116
Eye movements of patients with tunnel vision while walking.
Vargas-Martín, Fernando; Peli, Eli
2006-12-01
To determine how severe peripheral field loss (PFL) affects the dispersion of eye movements relative to the head in patients walking in real environments. This information should help to define the visual field and clearance requirements for head-mounted mobility visual aids. Eye positions relative to the head were recorded in five patients with retinitis pigmentosa who had less than 15 degrees of visual field and in three normally sighted people, each walking in varied environments for more than 30 minutes. The eye-position recorder was made portable by modifying a head-mounted system (ISCAN, Burlington, MA). Custom data processing was implemented, to reject unreliable data. Sample standard deviations of eye position (dispersion) were compared across subject groups and environments. The patients with PFL exhibited narrower horizontal eye-position dispersions than did the normally sighted subjects (9.4 degrees vs. 14.2 degrees , P < 0.0001), and the vertical dispersions of patients with PFL were smaller when they were walking indoors than when walking outdoors (8.2 degrees vs. 10.3 degrees ; P = 0.048). When walking, the patients with PFL did not increase their scanning eye movements to compensate for missing peripheral vision information. Their horizontal scanning was actually reduced, possibly because of lack of peripheral stimulation. The results suggest that a field of view as wide as 40 degrees may be needed for closed (immersive) head-mounted mobility aids, whereas a much narrower display, perhaps as narrow as 20 degrees , may be sufficient with an open design.
Frames of reference for gaze saccades evoked during stimulation of lateral intraparietal cortex.
Constantin, A G; Wang, H; Martinez-Trujillo, J C; Crawford, J D
2007-08-01
Previous studies suggest that stimulation of lateral intraparietal cortex (LIP) evokes saccadic eye movements toward eye- or head-fixed goals, whereas most single-unit studies suggest that LIP uses an eye-fixed frame with eye-position modulations. The goal of our study was to determine the reference frame for gaze shifts evoked during LIP stimulation in head-unrestrained monkeys. Two macaques (M1 and M2) were implanted with recording chambers over the right intraparietal sulcus and with search coils for recording three-dimensional eye and head movements. The LIP region was microstimulated using pulse trains of 300 Hz, 100-150 microA, and 200 ms. Eighty-five putative LIP sites in M1 and 194 putative sites in M2 were used in our quantitative analysis throughout this study. Average amplitude of the stimulation-evoked gaze shifts was 8.67 degrees for M1 and 7.97 degrees for M2 with very small head movements. When these gaze-shift trajectories were rotated into three coordinate frames (eye, head, and body), gaze endpoint distribution for all sites was most convergent to a common point when plotted in eye coordinates. Across all sites, the eye-centered model provided a significantly better fit compared with the head, body, or fixed-vector models (where the latter model signifies no modulation of the gaze trajectory as a function of initial gaze position). Moreover, the probability of evoking a gaze shift from any one particular position was modulated by the current gaze direction (independent of saccade direction). These results provide causal evidence that the motor commands from LIP encode gaze command in eye-fixed coordinates but are also subtly modulated by initial gaze position.
Rauen, Matthew P; Goins, Kenneth M; Sutphin, John E; Kitzmann, Anna S; Schmidt, Gregory A; Wagoner, Michael D
2012-04-01
To determine if the lamellar cut of donor tissue for endothelial keratoplasty (EK) by an eye bank facility is associated with a change in the prevalence of positive bacterial or fungal donor rim cultures after corneal transplantation. A retrospective review was conducted of bacterial and fungal cultures of donor rims used for corneal transplantation at a tertiary eye care center from January 1, 2003, to December 31, 2008, with tissue provided by a single eye bank. The cases were divided into 2 groups. Group 1 ("no-cut") included keratoplasty procedures in which a lamellar cut was not performed. Group 2 ("precut") included EK procedures in which a 4-hour period of prewarming of tissue followed by a lamellar cut was performed in the eye bank before tissue delivery to the operating surgeon. There were 351 donor rim cultures in group 1 and 278 in group 2. Bacterial cultures were positive in 30 donor rims (8.5%) in group 1 and 13 (4.7%) in group 2 (P = 0.058). Positive bacterial cultures were not associated with any postoperative infections. Fungal cultures were positive in 8 donor rims (2.3%) in group 1 and 7 (2.5%) in group 2 (P = 1.0). Positive fungal cultures were associated with 2 cases (13.3%) of postoperative fungal infections. Corneal donor tissue can be precut for EK by trained eye bank personnel without an increased risk of bacterial or fungal contamination.
Heo, Hwan; Lee, Won Oh; Shin, Kwang Yong; Park, Kang Ryoung
2014-01-01
We propose a new method for measuring the degree of eyestrain on 3D stereoscopic displays using a glasses-type of eye tracking device. Our study is novel in the following four ways: first, the circular area where a user's gaze position exists is defined based on the calculated gaze position and gaze estimation error. Within this circular area, the position where edge strength is maximized can be detected, and we determine this position as the gaze position that has a higher probability of being the correct one. Based on this gaze point, the eye foveation model is defined. Second, we quantitatively evaluate the correlation between the degree of eyestrain and the causal factors of visual fatigue, such as the degree of change of stereoscopic disparity (CSD), stereoscopic disparity (SD), frame cancellation effect (FCE), and edge component (EC) of the 3D stereoscopic display using the eye foveation model. Third, by comparing the eyestrain in conventional 3D video and experimental 3D sample video, we analyze the characteristics of eyestrain according to various factors and types of 3D video. Fourth, by comparing the eyestrain with or without the compensation of eye saccades movement in 3D video, we analyze the characteristics of eyestrain according to the types of eye movements in 3D video. Experimental results show that the degree of CSD causes more eyestrain than other factors. PMID:24834910
Raphan, T
1998-05-01
This study evaluates the effects of muscle axis shifts on the performance of a vector velocity-position integrator in the CNS. Earlier models of the oculomotor plant assumed that the muscle axes remained fixed relative to the head as the eye rotated into secondary and tertiary eye positions. Under this assumption, the vector integrator model generates torsional transients as the eye moves from secondary to tertiary positions of fixation. The torsional transient represents an eye movement response to a spatial mismatch between the torque axes that remain fixed in the head and the displacement plane that changes by half the angle of the change in eye orientation. When muscle axis shifts were incorporated into the model, the torque axes were closer to the displacement plane at each eye orientation throughout the trajectory, and torsional transients were reduced dramatically. Their size and dynamics were close to reported data. It was also shown that when the muscle torque axes were rotated by 50% of the eye rotation, there was no torsional transient and Listing's law was perfectly obeyed. When muscle torque axes rotated >50%, torsional transients reversed direction compared with what occurred for muscle axis shifts of <50%. The model indicates that Listing's law is implemented by the oculomotor plant subject to a two-dimensional command signal that is confined to the pitch-yaw plane, having zero torsion. Saccades that bring the eye to orientations outside Listing's plane could easily be corrected by a roll pulse that resets the roll state of the velocity-position integrator to zero. This would be a simple implementation of the corrective controller suggested by Van Opstal and colleagues. The model further indicates that muscle axis shifts together with the torque orientation relationship for tissue surrounding the eye and Newton's laws of motion form a sufficient plant model to explain saccadic trajectories and periods of fixation when driven by a vector command confined to the pitch-yaw plane. This implies that the velocity-position integrator is probably realized as a subtractive feedback vector integrator and not as a quaternion-based integrator that implements kinematic transformations to orient the eye.
Context-specific adaptation of pursuit initiation in humans
NASA Technical Reports Server (NTRS)
Takagi, M.; Abe, H.; Hasegawa, S.; Usui, T.; Hasebe, H.; Miki, A.; Zee, D. S.; Shelhauser, M. (Principal Investigator)
2000-01-01
PURPOSE: To determine if multiple states for the initiation of pursuit, as assessed by acceleration in the "open-loop" period, can be learned and gated by context. METHODS: Four normal subjects were studied. A modified step-ramp paradigm for horizontal pursuit was used to induce adaptation. In an increasing paradigm, target velocity doubled 230 msec after onset; in a decreasing paradigm, it was halved. In the first experiment, vertical eye position (+/-5 degrees ) was used as the context cue, and the training paradigm (increasing or decreasing) changed with vertical eye position. In the second experiment, with vertical position constant, when the target was red, training was decreasing, and when green, increasing. The average eye acceleration in the first 100 msec of tracking was the index of open-loop pursuit performance. RESULTS: With vertical position as the cue, pursuit adaptation differed between up and down gaze. In some cases, the direction of adaptation was in exact accord with the training stimuli. In others, acceleration increased or decreased for both up and down gaze but always in correct relative proportion to the training stimuli. In contrast, multiple adaptive states were not induced with color as the cue. CONCLUSIONS: Multiple values for the relationship between the average eye acceleration during the initiation of pursuit and target velocity could be learned and gated by context. Vertical position was an effective contextual cue but not target color, implying that useful contextual cues must be similar to those occurring naturally, for example, orbital position with eye muscle weakness.
NASA Technical Reports Server (NTRS)
Thurtell, M. J.; Kunin, M.; Raphan, T.; Wall, C. C. (Principal Investigator)
2000-01-01
It is well established that the head and eye velocity axes do not always align during compensatory vestibular slow phases. It has been shown that the eye velocity axis systematically tilts away from the head velocity axis in a manner that is dependent on eye-in-head position. The mechanisms responsible for producing these axis tilts are unclear. In this model-based study, we aimed to determine whether muscle pulleys could be involved in bringing about these phenomena. The model presented incorporates semicircular canals, central vestibular pathways, and an ocular motor plant with pulleys. The pulleys were modeled so that they brought about a rotation of the torque axes of the extraocular muscles that was a fraction of the angle of eye deviation from primary position. The degree to which the pulleys rotated the torque axes was altered by means of a pulley coefficient. Model input was head velocity and initial eye position data from passive and active yaw head impulses with fixation at 0 degrees, 20 degrees up and 20 degrees down, obtained from a previous experiment. The optimal pulley coefficient required to fit the data was determined by calculating the mean square error between data and model predictions of torsional eye velocity. For active head impulses, the optimal pulley coefficient varied considerably between subjects. The median optimal pulley coefficient was found to be 0.5, the pulley coefficient required for producing saccades that perfectly obey Listing's law when using a two-dimensional saccadic pulse signal. The model predicted the direction of the axis tilts observed in response to passive head impulses from 50 ms after onset. During passive head impulses, the median optimal pulley coefficient was found to be 0.21, when roll gain was fixed at 0.7. The model did not accurately predict the alignment of the eye and head velocity axes that was observed early in the response to passive head impulses. We found that this alignment could be well predicted if the roll gain of the angular vestibuloocular reflex was modified during the initial period of the response, while pulley coefficient was maintained at 0.5. Hence a roll gain modification allows stabilization of the retinal image without requiring a change in the pulley effect. Our results therefore indicate that the eye position-dependent velocity axis tilts could arise due to the effects of the pulleys and that a roll gain modification in the central vestibular structures may be responsible for countering the pulley effect.
Ultrasound biomicroscopy. High-frequency ultrasound imaging of the eye at microscopic resolution.
Pavlin, C J; Foster, F S
1998-11-01
UBM presents us with a new method of imaging the anterior segment of the eye at high resolution. Its strengths lie in its ability to produce cross-sections of the living eye at microscopic resolution without violating the integrity of the globe. UBM, although lacking the resolution of optical microscopy, gives us images in living eyes without affecting the internal relationships of the structures imaged. There are many other applications of this new imaging method. Examples of other uses include imaging adnexal pathology, assessing corneal changes with refractive surgery, the assessment of trauma, and determination of intraocular lens position.
Comparison of noncontact infrared and remote sensor thermometry in normal and dry eye patients.
Singh, G; Singh Bhinder, H
To evaluate the role of closed chamber infrared and remote sensor thermometry in normal and dry eye patients. The study was conducted on 51 dry eye cases (102 eyes), 26 men and 25 women aged 19 to 65 years (35.3614.36), and 51 normal (102 eyes) age- and sex-matched control subjects. The criteria for dry eye were Schirm e r-1 (<10 m/5 min), FTBUT (<10 sec), nd lissamine green score (>2). The remote sensor and infrared thermometry was done in losed chamber around the eye in closed and open eye positions. In normal eyes, closed chamber infrared thermometry recorded temperature 34.770.37 C in closed eye position and 35.020.39 C in open eye position as compared to 27.912.46 C in closed eye position and 28.012.46 C in open position with remote sensor thermometry. The difference in temperature from closed to open position was 0.250.90 C in infrared thermometry and 0.100.00 C with remote sensor thermometry, which was statistically significant (p<0.0000). In dry eye, the infrared therm o m e t ry recorded 35.080.61 C temperature in closed eye position and 35.530.63 C in open eye position as compared to 27.412.48 C in open and closed eye position with remote sensor thermometry. The difference in temperature from closed to open eye position was 0.450.14 C (p<0.0000) with infrared thermometry as compared to no change 0.000.00 C with remote sensor thermometry (p<0.0000). Remote sensor thermometry proved better for diagnosis of dry eye disease as it showed no change in temperature under closed chamber in closed and open position (p=0.0000). Infrared thermometry was better in recording the absolute temperature from any point on the eye.
Comparison of noncontact infrared and remote sensor thermometry in normal and dry eye patients.
Singh, G; Bhinder, H Singh
2005-01-01
To evaluate the role of closed chamber infrared and remote sensor thermometry in normal and dry eye patients. The study was conducted on 51 dry eye cases (102 eyes), 26 men and 25 women aged 19 to 65 years (35.36+/-14.36), and 51 normal (102 eyes) age- and sex-matched control subjects. The criteria for dry eye were Schirmer-1 (<10 m/5 min), FTBUT (<10 sec), nd lissamine green score (>2). The remote sensor and infrared thermometry was done in closed chamber around the eye in closed and open eye positions. In normal eyes, closed chamber infrared thermometry recorded temperature 34.77+/-0.37 degrees C in closed eye position and 35.02+/-0.39 degrees C in open eye position as compared to 27.91+/-2.46 degrees C in closed eye position and 28.01+/-2.46 degrees C in open position with remote sensor thermometry. The difference in temperature from closed to open position was 0.25+/-0.90 degrees C in infrared thermometry and 0.10+/-0.00 degrees C with remote sensor thermometry, which was statistically significant (p<0.0000). In dry eye, the infrared thermometry recorded 35.08+/-0.61 degrees C temperature in closed eye position and 35.53+/-0.63 degrees C in open eye position as compared to 27.41+/-2.48 degrees C in open and closed eye position with remote sensor thermometry. The difference in temperature from closed to open eye position was 0.45+/-0.14 degrees C (p<0.0000) with infrared thermometry as compared to no change 0.00+/-0.00 degrees C with remote sensor thermometry (p<0.0000). Remote sensor thermometry proved better for diagnosis of dry eye disease as it showed no change in temperature under closed chamber in closed and open position (p=0.0000). Infrared thermometry was better in recording the absolute temperature from any point on the eye.
Subbiah, Sujata; Thomas, Philip A; Nelson Jesudasan, C A
2017-08-01
To compare data on anatomical and biometric parameters, and their combination, obtained by using ultrasound biomicroscopy (UBM) and A-scan in eyes with phacomorphic glaucoma (PG) and eyes with mature cataract and to determine differences that may predispose to development of PG. Eighty patients (80 eyes) were enrolled in this cross-sectional study. Anterior chamber parameters, namely anterior chamber depth (ACD), angle-opening distance (AOD), iris-lens contact distance (ILCD), and trabecular-ciliary process distance (TCPD), among other parameters, were assessed by UBM (35 MHz), while axial length (AL) and lenticular thickness (LT) were determined by A-scan biometry. Absolute lenticular position (ALP) and relative lenticular position (RLP) were also compared. The mean AL of eyes with PG was less (P = 0.64) than the mean AL of eyes with mature cataract. The mean ILCD value in eyes with PG (1.30 ± 0.78 mm) was significantly higher (P = 0.0015) than that in eyes with mature cataract (0.86 ± 0.32 mm). The mean AOD value in eyes with PG (0.15 ± 0.10 mm) was significantly lower (P < 0.0001) than that in eyes with mature cataract (0.23 ± 0.06 mm); similarly, the mean RLP value in eyes with PG (0.20 ± 0.02) was significantly lower (P < 0.0001) than that in eyes with mature cataract (0.17 ± 0.02). TCPD showed negative correlation with LT r = -0.514; P = 0.017, r 2 = 0.264, in eyes with phacomorphic glaucoma and mature cataracts showed significant negative correlation of ILCD with AL (r = -0.575; P = 0.025, r 2 = 0.330). The results of UBM examination suggest that there are multiple mechanisms underlying the pathophysiology of PG, namely crowding of the anterior segment, increased iris-lens contact distance, and a more pronounced anterior shift of the lens. Simultaneous evaluation of anatomic and biometric parameters can improve diagnostic accuracy in predicting cases at risk for PG.
Clinical and biometric determinants of actual lens position after cataract surgery.
Plat, Julien; Hoa, Didier; Mura, Frederic; Busetto, Timothe; Schneider, Christelle; Payerols, Arnaud; Villain, Max; Daien, Vincent
2017-02-01
To evaluate the preoperative clinical and biometric determinants associated with the actual lens position after cataract surgery. Department of Ophthalmology, University Hospital of Montpellier, France. Prospective longitudinal cohort study. The data collected included clinical factors (age, sex, history of vitrectomy) and biometry factors (axial length [AL], anterior chamber depth [ACD], lens thickness, white-to-white [WTW] distance) that might affect actual lens position. Each patient had optical low-coherence reflectometry biometry (Lenstar) preoperatively and 1 month postoperatively. The actual lens position was measured as the postoperative position of the center of the intraocular lens (IOL). Patients were stratified into 3 groups by type of IOL: Acrysof SN60WF or SN6AT (Group 1), Tecnis ZCB00 or ZCT (Group 2), and Asphina 409 MV (Group 3). The study comprised 168 eyes (mean age 73.3 years ± 9.8 [SD]). The mean actual lens position was 4.88 ± 0.29 mm, 5.01 ± 0.29 mm, and 5.05 ± 0.32 mm in Group 1 (n = 67 eyes), Group 2 (n = 52 eyes), and Group 3 (n = 49 eyes), respectively. In the overall population, AL, ACD, anterior segment depth, and WTW distance were correlated with actual lens position (r = 0.48, P < .0001; r = 0.64, P < .001; r = 0.58, P < .0001; r = 0.39, P < .001, respectively). The AL, ACD, anterior segment depth, and WTW distance correlated with actual lens position after cataract surgery. The integration of these data in IOL formulas could help improve refractive outcomes after the surgery. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Accommodation and the Visual Regulation of Refractive State in Marmosets
Troilo, David; Totonelly, Kristen; Harb, Elise
2009-01-01
Purpose To determine the effects of imposed anisometropic retinal defocus on accommodation, ocular growth, and refractive state changes in marmosets. Methods Marmosets were raised with extended-wear soft contact lenses for an average duration of 10 wks beginning at an average age of 76 d. Experimental animals wore either a positive or negative contact lens over one eye and a plano lens or no lens over the other. Another group wore binocular lenses of equal magnitude but opposite sign. Untreated marmosets served as controls and three wore plano lenses monocularly. Cycloplegic refractive state, corneal curvature, and vitreous chamber depth were measured before, during, and after the period of lens wear. To investigate the accommodative response, the effective refractive state was measured through each anisometropic condition at varying accommodative stimuli positions using an infrared refractometer. Results Eye growth and refractive state are significantly correlated with the sign and power of the contact lens worn. The eyes of marmosets reared with monocular negative power lenses had longer vitreous chambers and were myopic relative to contralateral control eyes (p<0.01). Monocular positive power lenses produced a significant reduction in vitreous chamber depth and hyperopia relative to the contralateral control eyes (p<0.05). In marmosets reared binocularly with lenses of opposite sign, we found larger interocular differences in vitreous chamber depths and refractive state (p<0.001). Accommodation influences the defocus experienced through the lenses, however, the mean effective refractive state was still hyperopia in the negative-lens-treated eyes and myopia in the positive-lens-treated eyes. Conclusions Imposed anisometropia effectively alters marmoset eye growth and refractive state to compensate for the imposed defocus. The response to imposed hyperopia is larger and faster than the response to imposed myopia. The pattern of accommodation under imposed anisometropia produces effective refractive states that are consistent with the changes in eye growth and refractive state observed. PMID:19104464
Laterality Influences Schooling Position in Rainbowfish, Melanotaenia spp
Bibost, Anne-Laurence; Brown, Culum
2013-01-01
Cerebral lateralization is a widespread trait among animals, is often manifested as side biases in behaviour (laterality) and has been suggested to provide fitness benefits. Here we examined the influence of laterality on the organisation of fish schools using rainbowfish (Melanotaenia spp) as model species. The pattern and strength of laterality for each individual was determined by examining eye preferences whilst examining their reflection in a mirror. Schools of four fish of known laterality were then created and the preferred position for each fish within the school was repeatedly observed in a flume. Fish which showed right eye preferences in the mirror test preferentially adopted a position on the left side of the school. Conversely, fish that showed left eye preferences in the mirror test or where non-lateralised preferentially adopted a position slightly to the right side of the school. However, this general pattern varied depending on the species and sex of the school. Our results strongly implicate individual laterality in the geometry of school formation. PMID:24260506
Laterality influences schooling position in rainbowfish, Melanotaenia spp.
Bibost, Anne-Laurence; Brown, Culum
2013-01-01
Cerebral lateralization is a widespread trait among animals, is often manifested as side biases in behaviour (laterality) and has been suggested to provide fitness benefits. Here we examined the influence of laterality on the organisation of fish schools using rainbowfish (Melanotaenia spp) as model species. The pattern and strength of laterality for each individual was determined by examining eye preferences whilst examining their reflection in a mirror. Schools of four fish of known laterality were then created and the preferred position for each fish within the school was repeatedly observed in a flume. Fish which showed right eye preferences in the mirror test preferentially adopted a position on the left side of the school. Conversely, fish that showed left eye preferences in the mirror test or where non-lateralised preferentially adopted a position slightly to the right side of the school. However, this general pattern varied depending on the species and sex of the school. Our results strongly implicate individual laterality in the geometry of school formation.
Samadani, Uzma; Ritlop, Robert; Reyes, Marleen; Nehrbass, Elena; Li, Meng; Lamm, Elizabeth; Schneider, Julia; Shimunov, David; Sava, Maria; Kolecki, Radek; Burris, Paige; Altomare, Lindsey; Mehmood, Talha; Smith, Theodore; Huang, Jason H; McStay, Christopher; Todd, S Rob; Qian, Meng; Kondziolka, Douglas; Wall, Stephen; Huang, Paul
2015-04-15
Disconjugate eye movements have been associated with traumatic brain injury since ancient times. Ocular motility dysfunction may be present in up to 90% of patients with concussion or blast injury. We developed an algorithm for eye tracking in which the Cartesian coordinates of the right and left pupils are tracked over 200 sec and compared to each other as a subject watches a short film clip moving inside an aperture on a computer screen. We prospectively eye tracked 64 normal healthy noninjured control subjects and compared findings to 75 trauma subjects with either a positive head computed tomography (CT) scan (n=13), negative head CT (n=39), or nonhead injury (n=23) to determine whether eye tracking would reveal the disconjugate gaze associated with both structural brain injury and concussion. Tracking metrics were then correlated to the clinical concussion measure Sport Concussion Assessment Tool 3 (SCAT3) in trauma patients. Five out of five measures of horizontal disconjugacy were increased in positive and negative head CT patients relative to noninjured control subjects. Only one of five vertical disconjugacy measures was significantly increased in brain-injured patients relative to controls. Linear regression analysis of all 75 trauma patients demonstrated that three metrics for horizontal disconjugacy negatively correlated with SCAT3 symptom severity score and positively correlated with total Standardized Assessment of Concussion score. Abnormal eye-tracking metrics improved over time toward baseline in brain-injured subjects observed in follow-up. Eye tracking may help quantify the severity of ocular motility disruption associated with concussion and structural brain injury.
Ritlop, Robert; Reyes, Marleen; Nehrbass, Elena; Li, Meng; Lamm, Elizabeth; Schneider, Julia; Shimunov, David; Sava, Maria; Kolecki, Radek; Burris, Paige; Altomare, Lindsey; Mehmood, Talha; Smith, Theodore; Huang, Jason H.; McStay, Christopher; Todd, S. Rob; Qian, Meng; Kondziolka, Douglas; Wall, Stephen; Huang, Paul
2015-01-01
Abstract Disconjugate eye movements have been associated with traumatic brain injury since ancient times. Ocular motility dysfunction may be present in up to 90% of patients with concussion or blast injury. We developed an algorithm for eye tracking in which the Cartesian coordinates of the right and left pupils are tracked over 200 sec and compared to each other as a subject watches a short film clip moving inside an aperture on a computer screen. We prospectively eye tracked 64 normal healthy noninjured control subjects and compared findings to 75 trauma subjects with either a positive head computed tomography (CT) scan (n=13), negative head CT (n=39), or nonhead injury (n=23) to determine whether eye tracking would reveal the disconjugate gaze associated with both structural brain injury and concussion. Tracking metrics were then correlated to the clinical concussion measure Sport Concussion Assessment Tool 3 (SCAT3) in trauma patients. Five out of five measures of horizontal disconjugacy were increased in positive and negative head CT patients relative to noninjured control subjects. Only one of five vertical disconjugacy measures was significantly increased in brain-injured patients relative to controls. Linear regression analysis of all 75 trauma patients demonstrated that three metrics for horizontal disconjugacy negatively correlated with SCAT3 symptom severity score and positively correlated with total Standardized Assessment of Concussion score. Abnormal eye-tracking metrics improved over time toward baseline in brain-injured subjects observed in follow-up. Eye tracking may help quantify the severity of ocular motility disruption associated with concussion and structural brain injury. PMID:25582436
Image-size differences worsen stereopsis independent of eye position
Vlaskamp, Björn N. S.; Filippini, Heather R.; Banks, Martin S.
2010-01-01
With the eyes in forward gaze, stereo performance worsens when one eye’s image is larger than the other’s. Near, eccentric objects naturally create retinal images of different sizes. Does this mean that stereopsis exhibits deficits for such stimuli? Or does the visual system compensate for the predictable image-size differences? To answer this, we measured discrimination of a disparity-defined shape for different relative image sizes. We did so for different gaze directions, some compatible with the image-size difference and some not. Magnifications of 10–15% caused a clear worsening of stereo performance. The worsening was determined only by relative image size and not by eye position. This shows that no neural compensation for image-size differences accompanies eye-position changes, at least prior to disparity estimation. We also found that a local cross-correlation model for disparity estimation performs like humans in the same task, suggesting that the decrease in stereo performance due to image-size differences is a byproduct of the disparity-estimation method. Finally, we looked for compensation in an observer who has constantly different image sizes due to differing eye lengths. She performed best when the presented images were roughly the same size, indicating that she has compensated for the persistent image-size difference. PMID:19271927
Gerling, J; de Paz, H; Schroth, V; Bach, M; Kommerell, G
2000-06-01
The theory of the "Measuring and Correction Methods of H.-J. Haase" (MCH) states that a small misalignment of one eye, called fixation disparity, indicates a difficulty in overcoming a "vergence position of rest" that is different from ortho position. This difficulty, so the theory, can cause asthenopic complaints, such as headaches, and these complaints can be relieved by prisms. The theory further claims that fixation disparity can be ascertained by a series of tests which depend on the subject's perception. The tests most decisive for the diagnosis of a so-called fixation disparity type 2 consist of stereo displays. The magnitude of the prism that allows the subject to see the test configurations in symmetry is thought to be the one that corrects the "vergence position of rest". Nine subjects with healthy eyes in whom a "fixation disparity type 2" had been diagnosed were selected for the study. Misalignment of the eyes was determined according to the principle of the unilateral cover test. Targets identical for both eyes were presented on the screen of the Polatest E. Then, the target was deleted for one eye and the ensuing position change of the other eye was measured, using the search coil technique. This test was performed both with and without the MCH prism. In all 9 subjects the misalignment was less than 10 minutes of arc, i.e. in the range of normal fixation instability. Averaging across the 9 subjects, the deviation of the eye (misaligned according to MCH) was 0.79 +/- 3.45 minutes of arc in the direction opposed to that predicted by the MCH, a value not significantly different from zero. The MCH prism elicited a fusional vergence movement the magnitude of which corresponded to the magnitude of the MCH prism. Ascertaining fixation disparity with the MCH is unreliable. Accordingly, it appears dubious to correct a "vergence position of rest" on the basis of the MCH.
Gaze holding deficits discriminate early from late onset cerebellar degeneration.
Tarnutzer, Alexander A; Weber, K P; Schuknecht, B; Straumann, D; Marti, S; Bertolini, G
2015-08-01
The vestibulo-cerebellum calibrates the output of the inherently leaky brainstem neural velocity-to-position integrator to provide stable gaze holding. In healthy humans small-amplitude centrifugal nystagmus is present at extreme gaze-angles, with a non-linear relationship between eye-drift velocity and eye eccentricity. In cerebellar degeneration this calibration is impaired, resulting in pathological gaze-evoked nystagmus (GEN). For cerebellar dysfunction, increased eye drift may be present at any gaze angle (reflecting pure scaling of eye drift found in controls) or restricted to far-lateral gaze (reflecting changes in shape of the non-linear relationship) and resulting eyed-drift patterns could be related to specific disorders. We recorded horizontal eye positions in 21 patients with cerebellar neurodegeneration (gaze-angle = ±40°) and clinically confirmed GEN. Eye-drift velocity, linearity and symmetry of drift were determined. MR-images were assessed for cerebellar atrophy. In our patients, the relation between eye-drift velocity and gaze eccentricity was non-linear, yielding (compared to controls) significant GEN at gaze-eccentricities ≥20°. Pure scaling was most frequently observed (n = 10/18), followed by pure shape-changing (n = 4/18) and a mixed pattern (n = 4/18). Pure shape-changing patients were significantly (p = 0.001) younger at disease-onset compared to pure scaling patients. Atrophy centered around the superior/dorsal vermis, flocculus/paraflocculus and dentate nucleus and did not correlate with the specific drift behaviors observed. Eye drift in cerebellar degeneration varies in magnitude; however, it retains its non-linear properties. With different drift patterns being linked to age at disease-onset, we propose that the gaze-holding pattern (scaling vs. shape-changing) may discriminate early- from late-onset cerebellar degeneration. Whether this allows a distinction among specific cerebellar disorders remains to be determined.
Is there a common motor dysregulation in sleepwalking and REM sleep behaviour disorder?
Haridi, Mehdi; Weyn Banningh, Sebastian; Clé, Marion; Leu-Semenescu, Smaranda; Vidailhet, Marie; Arnulf, Isabelle
2017-10-01
This study sought to determine if there is any overlap between the two major non-rapid eye movement and rapid eye movement parasomnias, i.e. sleepwalking/sleep terrors and rapid eye movement sleep behaviour disorder. We assessed adult patients with sleepwalking/sleep terrors using rapid eye movement sleep behaviour disorder screening questionnaires and determined if they had enhanced muscle tone during rapid eye movement sleep. Conversely, we assessed rapid eye movement sleep behaviour disorder patients using the Paris Arousal Disorders Severity Scale and determined if they had more N3 awakenings. The 251 participants included 64 patients with rapid eye movement sleep behaviour disorder (29 with idiopathic rapid eye movement sleep behaviour disorder and 35 with rapid eye movement sleep behaviour disorder associated with Parkinson's disease), 62 patients with sleepwalking/sleep terrors, 66 old healthy controls (age-matched with the rapid eye movement sleep behaviour disorder group) and 59 young healthy controls (age-matched with the sleepwalking/sleep terrors group). They completed the rapid eye movement sleep behaviour disorder screening questionnaire, rapid eye movement sleep behaviour disorder single question and Paris Arousal Disorders Severity Scale. In addition, all the participants underwent a video-polysomnography. The sleepwalking/sleep terrors patients scored positive on rapid eye movement sleep behaviour disorder scales and had a higher percentage of 'any' phasic rapid eye movement sleep without atonia when compared with controls; however, these patients did not have higher tonic rapid eye movement sleep without atonia or complex behaviours during rapid eye movement sleep. Patients with rapid eye movement sleep behaviour disorder had moderately elevated scores on the Paris Arousal Disorders Severity Scale but did not exhibit more N3 arousals (suggestive of non-rapid eye movement parasomnia) than the control group. These results indicate that dream-enacting behaviours (assessed by rapid eye movement sleep behaviour disorder screening questionnaires) are commonly reported by sleepwalking/sleep terrors patients, thus decreasing the questionnaire's specificity. Furthermore, sleepwalking/sleep terrors patients have excessive twitching during rapid eye movement sleep, which may result either from a higher dreaming activity in rapid eye movement sleep or from a more generalised non-rapid eye movement/rapid eye movement motor dyscontrol during sleep. © 2017 European Sleep Research Society.
Parks, Connie L; Monson, Keith L
2016-09-01
Expanding on research previously reported by the authors, this study further examines the recognizability of ReFace facial approximations generated with the following eye orb positions: (i) centrally within the bony eye socket, (ii) 1.0mm superior and 2.0mm lateral relative to center, and (iii) 1.0mm superior and 2.5mm lateral relative to center. Overall, 81% of the test subjects' approximation ranks improved with the use of either of the two supero-lateral eye orbs. Highly significant performance differences (p<0.01) were observed between the approximations with centrally positioned eye orbs (i) and approximations with the eye orbs placed in the supero-laterally positions (ii and iii). Noteworthy was the observation that in all cases when the best rank for an approximation was obtained with the eye orbs in position (iii), the second best rank was achieved with the eye orbs in position (ii). A similar pattern was also observed when the best rank was obtained with the eye orbs in position (ii), with 60% of the second best ranks observed in position (iii). It is argued, therefore, that an approximation constructed with the eye orbs placed in either of the two supero-lateral positions may be more effective and operationally informative than centrally positioned orbs. Copyright © 2016. Published by Elsevier Ireland Ltd.
New methods for the assessment of accommodative convergence.
Asakawa, Ken; Ishikawa, Hitoshi; Shoji, Nobuyuki
2009-01-01
The authors introduced a new objective method for measuring horizontal eye movements based on the first Purkinje image with the use of infrared charge-coupled device (CCD) cameras and compared stimulus accommodative convergence to accommodation (AC/A) ratios as determined by a standard gradient method. The study included 20 patients, 5 to 9 years old, who had intermittent exotropia (10 eyes) and accommodative esotropia (10 eyes). Measurement of horizontal eye movements in millimeters (mm), based on the first Purkinje image, was obtained with a TriIRIS C9000 instrument (Hamamatsu Photonics K.K., Hamamatsu, Japan). The stimulus AC/A ratio was determined with the far gradient method. The average values of horizontal eye movements (mm) and eye deviation (Delta) (a) before and (b) after an accommodative stimulus of 3.00 diopters (D) were calculated with the following formula: horizontal eye movements (mm/D) and stimulus AC/A ratio (Delta/D) = (b - a)/3. The average values of the horizontal eye movements and the stimulus AC/A ratio were 0.5 mm/D and 3.8 Delta/D, respectively. Correlation analysis showed a strong positive correlation between these two parameters (r = 0.92). Moreover, horizontal eye movements are directly proportional to the AC/A ratio measured with the gradient method. The methods used in this study allow objective recordings of accommodative convergence to be obtained in many clinical situations. Copyright 2009, SLACK Incorporated.
Matching between the light spots and lenslets of an artificial compound eye system
NASA Astrophysics Data System (ADS)
He, Jianzheng; Jian, Huijie; Zhu, Qitao; Ma, Mengchao; Wang, Keyi
2017-10-01
As the visual organ of many arthropods, the compound eye has attracted a lot of attention with the advantage of wide field-of-view, multi-channel imaging ability and high agility. Extended from this concept, a new kind of artificial compound eye device is developed. There are 141 lenslets which share one image sensor distributed evenly on a curved surface, thus it is difficult to distinguish the lenslets which the light spot belongs to during calibration and positioning process. Therefore, the matching algorithm is proposed based on the device structure and the principle of calibration and positioning. Region partition of lenslet array is performed at first. Each lenslet and its adjacent lenslets are defined as cluster eyes and constructed into an index table. In the calibration process, a polar coordinate system is established, and the matching can be accomplished by comparing the rotary table position in the polar coordinate system and the central light spot angle in the image. In the positioning process, the spot is paired to the correct region according to the spots distribution firstly, and the final results is determined by the dispersion of the distance from the target point to the incident ray in the region traversal matching. Finally, the experiment results show that the presented algorithms provide a feasible and efficient way to match the spot to the lenslet, and perfectly meet the needs in the practical application of the compound eye system.
Performing saccadic eye movements or blinking improves postural control.
Rougier, Patrice; Garin, Mélanie
2007-07-01
To determine the relationship between eye movement and postural control on an undisturbed upright stance maintenance protocol, 15 young, healthy individuals were tested in various conditions. These conditions included imposed blinking patterns and horizontal and vertical saccadic eye movements. The directions taken by the center of pressure (CP) were recorded via a force platform on which the participants remained in an upright position. The CP trajectories were used to estimate, via a low-pass filter, the vertically projected movements of the center of gravity (CGv) and consequently the difference CP-CGv. An analysis of the frequency shows that regular bilateral blinking does not produce a significant change in postural control. In contrast, performing saccadic eye movements induces some reduced amplitude for both basic CGv and CP-CGv movements principally along the antero-posterior axis. The present result supports the theory that some ocular movements may modify postural control in the maintenance of the upright standing position in human participants.
Arba-Mosquera, Samuel; Aslanides, Ioannis M.
2012-01-01
Purpose To analyze the effects of Eye-Tracker performance on the pulse positioning errors during refractive surgery. Methods A comprehensive model, which directly considers eye movements, including saccades, vestibular, optokinetic, vergence, and miniature, as well as, eye-tracker acquisition rate, eye-tracker latency time, scanner positioning time, laser firing rate, and laser trigger delay have been developed. Results Eye-tracker acquisition rates below 100 Hz correspond to pulse positioning errors above 1.5 mm. Eye-tracker latency times to about 15 ms correspond to pulse positioning errors of up to 3.5 mm. Scanner positioning times to about 9 ms correspond to pulse positioning errors of up to 2 mm. Laser firing rates faster than eye-tracker acquisition rates basically duplicate pulse-positioning errors. Laser trigger delays to about 300 μs have minor to no impact on pulse-positioning errors. Conclusions The proposed model can be used for comparison of laser systems used for ablation processes. Due to the pseudo-random nature of eye movements, positioning errors of single pulses are much larger than observed decentrations in the clinical settings. There is no single parameter that ‘alone’ minimizes the positioning error. It is the optimal combination of the several parameters that minimizes the error. The results of this analysis are important to understand the limitations of correcting very irregular ablation patterns.
Remote vs. head-mounted eye-tracking: a comparison using radiologists reading mammograms
NASA Astrophysics Data System (ADS)
Mello-Thoms, Claudia; Gur, David
2007-03-01
Eye position monitoring has been used for decades in Radiology in order to determine how radiologists interpret medical images. Using these devices several discoveries about the perception/decision making process have been made, such as the importance of comparisons of perceived abnormalities with selected areas of the background, the likelihood that a true lesion will attract visual attention early in the reading process, and the finding that most misses attract prolonged visual dwell, often comparable to dwell in the location of reported lesions. However, eye position tracking is a cumbersome process, which often requires the observer to wear a helmet gear which contains the eye tracker per se and a magnetic head tracker, which allows for the computation of head position. Observers tend to complain of fatigue after wearing the gear for a prolonged time. Recently, with the advances made to remote eye-tracking, the use of head-mounted systems seemed destined to become a thing of the past. In this study we evaluated a remote eye tracking system, and compared it to a head-mounted system, as radiologists read a case set of one-view mammograms on a high-resolution display. We compared visual search parameters between the two systems, such as time to hit the location of the lesion for the first time, amount of dwell time in the location of the lesion, total time analyzing the image, etc. We also evaluated the observers' impressions of both systems, and what their perceptions were of the restrictions of each system.
Suzuki, Nami; Noh, Jaeduk Yoshimura; Kameda, Toshiaki; Yoshihara, Ai; Ohye, Hidemi; Suzuki, Miho; Matsumoto, Masako; Kunii, Yo; Iwaku, Kenji; Watanabe, Natsuko; Mukasa, Koji; Kozaki, Ai; Inoue, Toshu; Sugino, Kiminori; Ito, Koichi
2018-01-01
Euthyroid Graves' disease (EGD) is a rare condition defined as the presence of thyroid-associated ophthalmopathy (TAO) in patients with normal thyroid function. Due to the rarity of this disease, only a limited number of studies and case reports are available for further evaluation of the characteristics of the disease. The aim of this study was to examine the changes in the thyroid function, thyrotropin receptor antibodies (TRAb) and eye symptoms, and then determine whether TRAb is related to TAO in EGD patients. TRAb in this study was defined as including both thyrotropin-binding inhibitory immunoglobulin (TBII) and thyroid-stimulating immunoglobulin (TSAb). Medical records of patients diagnosed with EGD were reviewed. Ophthalmologists specializing in TAO examined the eyes of all subjects. Of the 58 patients diagnosed with EGD, 24.1% developed hyperthyroidism, while 3.4% developed hypothyroidism. A total of 72.4% of the 58 patients remained euthyroid throughout the entire follow-up period. At the initial presentation, TBII and TSAb were positive in 74.5% and 70.5%, respectively. Ophthalmic treatments were administered to 30 (51.7%) out of the 58 patients. A significant spontaneous improvement of the eye symptoms was found in 28 of the EGD patients who did not require eye treatments. EGD patients exhibited positive rates for both TBII and TSAb, with the number of the TRAb-positive patients gradually decreasing while the eye symptoms spontaneously improved over time. There were no correlations found between TRAb at initial presentation and the eye symptoms. TBII and TSAb were positive in about 70% of EGD patients at their initial visit. Thyroid functions of EGD patients who have been euthyroid for more than 6.7 years may continue to remain euthyroid in the future.
Primary position and listing's law in acquired and congenital trochlear nerve palsy.
Straumann, Dominik; Steffen, Heimo; Landau, Klara; Bergamin, Oliver; Mudgil, Ananth V; Walker, Mark F; Guyton, David L; Zee, David S
2003-10-01
In ocular kinematics, the primary position (PP) of the eye is defined by the position from which movements do not induce ocular rotations around the line of sight (Helmholtz). PP is mathematically linked to the orientation of Listing's plane. This study was conducted to determine whether PP is affected differently in patients with clinically diagnosed congenital (conTNP) and acquired (acqTNP) trochlear nerve palsy. Patients with unilateral conTNP (n = 25) and acqTNP (n = 9) performed a modified Hess screen test. Three-dimensional eye positions were recorded with dual search coils. PP in eyes with acqTNP was significantly more temporal (mean: 21.2 degrees ) than in eyes with conTNP (6.8 degrees ) or healthy eyes (7.2 degrees ). In the pooled data of all patients, the horizontal location of PP significantly correlated with vertical noncomitance with the paretic eye in adduction (R = 0.59). Using a computer model, PP in acqTNP could be reproduced by a neural lesion of the superior oblique (SO) muscle. An additional simulated overaction of the inferior oblique (IO) muscle moved PP back to normal, as in conTNP. Lengthening the SO and shortening the IO muscles could also simulate PP in conTNP. The temporal displacement of PP in acqTNP is a direct consequence of the reduced force of the SO muscle. The reversal of this temporal displacement of PP, which occurs in some patients with conTNP, can be explained by a secondary overaction of the IO muscle. Alternatively, length changes in the SO and IO muscles, or other anatomic anomalies within the orbit, without a neural lesion, may also explain the difference in location of PP between conTNP and acqTNP.
Fesharaki, Maryam; Karagiannis, Peter; Tweed, Douglas; Sharpe, James A.; Wong, Agnes M. F.
2016-01-01
Purpose Skew deviation is a vertical strabismus caused by damage to the otolithic–ocular reflex pathway and is associated with abnormal ocular torsion. This study was conducted to determine whether patients with skew deviation show the normal pattern of three-dimensional eye control called Listing’s law, which specifies the eye’s torsional angle as a function of its horizontal and vertical position. Methods Ten patients with skew deviation caused by brain stem or cerebellar lesions and nine normal control subjects were studied. Patients with diplopia and neurologic symptoms less than 1 month in duration were designated as acute (n = 4) and those with longer duration were classified as chronic (n = 10). Serial recordings were made in the four patients with acute skew deviation. With the head immobile, subjects made saccades to a target that moved between straight ahead and eight eccentric positions, while wearing search coils. At each target position, fixation was maintained for 3 seconds before the next saccade. From the eye position data, the plane of best fit, referred to as Listing’s plane, was fitted. Violations of Listing’s law were quantified by computing the “thickness” of this plane, defined as the SD of the distances to the plane from the data points. Results Both the hypertropic and hypotropic eyes in patients with acute skew deviation violated Listing’s and Donders’ laws—that is, the eyes did not show one consistent angle of torsion in any given gaze direction, but rather an abnormally wide range of torsional angles. In contrast, each eye in patients with chronic skew deviation obeyed the laws. However, in chronic skew deviation, Listing’s planes in both eyes had abnormal orientations. Conclusions Patients with acute skew deviation violated Listing’s law, whereas those with chronic skew deviation obeyed it, indicating that despite brain lesions, neural adaptation can restore Listing’s law so that the neural linkage between horizontal, vertical, and torsional eye position remains intact. Violation of Listing’s and Donders’ laws during fixation arises primarily from torsional drifts, indicating that patients with acute skew deviation have unstable torsional gaze holding that is independent of their horizontal–vertical eye positions. PMID:18172094
Pavilack, M A; Brod, R D
2001-02-01
To determine the site of focal illumination on the retina of phakic human cadaver eyes from an operating microscope positioned for temporal approach eye surgery. Experimental study. A Zeiss OPMI-6SFR operating microscope (Zeiss Humphrey Systems, Dublin, CA) was positioned over two phakic human cadaver eyes to measure the site of the focal illumination on the retina by directly observing the illumination on the posterior scleral surface of the globe. External localization of the foveola was made by direct observation using scleral indentation and indirect ophthalmoscopy. Various combinations of microscope angulation and field of view were analyzed. Distance of focal illumination from the operating room microscope relative to the foveola was measured. The diameter of the "hot spot" of focal illumination on the retina was 4.0 mm. With the eye positioned straight ahead and the level operating room microscope positioned for temporal approach eye surgery, the center of retinal illumination was 0.9 and 1.4 mm nasal relative to the foveola when the microscope field of view was centered over the cornea and temporal limbus, respectively. With the microscope angled 5, 10, 15, and 20 degrees temporally (oculars tilted toward surgeon), the center of the illumination was displaced nasal to the foveola by 1.1, 1.5, 3.8, and 5.1 mm, respectively, when the field of view was centered over the cornea and 1.5, 2.6, 4.7, and 6.0 mm, respectively, nasal to the foveola when centered over the temporal limbus. Retinal illumination from an operating microscope positioned for temporal approach eye surgery has the potential for light-induced injury to the fovea. Angulation of the operating microscope by up to 10 degrees temporally when the microscope field of view was centered over the cornea and up to 5 degrees temporally when centered over the temporal limbus was not adequate to displace the focal illumination off the foveola when the eye was in the straight-ahead position. Tilting the operating microscope 15 degrees or more temporally when centered on the pupil and 10 degrees or more when centered over the temporal limbus should safely displace the retinal light exposure away from the fovea during temporal approach surgery. Suggestions for reducing the risk of iatrogenic phototoxicity are reviewed.
Misslisch, H; Hess, B J M
2002-11-01
This study examined two kinematical features of the rotational vestibulo-ocular reflex (VOR) of the monkey in near vision. First, is there an effect of eye position on the axes of eye rotation during yaw, pitch and roll head rotations when the eyes are converged to fixate near targets? Second, do the three-dimensional positions of the left and right eye during yaw and roll head rotations obey the binocular extension of Listing's law (L2), showing eye position planes that rotate temporally by a quarter as far as the angle of horizontal vergence? Animals fixated near visual targets requiring 17 or 8.5 degrees vergence and placed at straight ahead, 20 degrees up, down, left, or right during yaw, pitch, and roll head rotations at 1 Hz. The 17 degrees vergence experiments were performed both with and without a structured visual background, the 8.5 degrees vergence experiments with a visual background only. A 40 degrees horizontal change in eye position never influenced the axis of eye rotation produced by the VOR during pitch head rotation. Eye position did not affect the VOR eye rotation axes, which stayed aligned with the yaw and roll head rotation axes, when torsional gain was high. If torsional gain was low, eccentric eye positions produced yaw and roll VOR eye rotation axes that tilted somewhat in the directions predicted by Listing's law, i.e., with or opposite to gaze during yaw or roll. These findings were seen in both visual conditions and in both vergence experiments. During yaw and roll head rotations with a 40 degrees vertical change in gaze, torsional eye position followed on average the prediction of L2: the left eye showed counterclockwise (ex-) torsion in down gaze and clockwise (in-) torsion in up gaze and vice versa for the right eye. In other words, the left and right eye's position plane rotated temporally by about a quarter of the horizontal vergence angle. Our results indicate that torsional gain is the central mechanism by which the brain adjusts the retinal image stabilizing function of the VOR both in far and near vision and the three dimensional eye positions during yaw and roll head rotations in near vision follow on average the predictions of L2, a kinematic pattern that is maintained by the saccadic/quick phase system.
Vijayakumar, Nithya P; Parikh, Purak; Mian, Shahzad I; Tennant, Brad; Grossman, Gregory H; Albrecht, Bob; Niziol, Leslie M; Woodward, Maria A
2018-03-01
Surgical use of donor corneal tissue from victims of water submersion (drowning or submersion secondary to death) remains controversial due to limited evidence about the quality of these tissues. To assess the safety of donor corneal tissue from victims of water submersion, an investigation of eye banks' practice patterns and tissue outcomes was conducted. All 79 Eye Bank Association of America accredited eye banks were contacted for a phone interview of practices regarding tissue from victims of water submersion. A retrospective review of corneal tissues from 2014 to 2016 from a large eye bank network was performed to identify all donors submerged in water. Corneal epithelial integrity, endothelial cell density (ECD), rim cultures, and adverse events were analyzed for associations with water submersion characteristics. 49 eye banks (62% response) participated in the survey. 55% of these eye banks had specific, written protocol for tissue eligibility from donors submerged in water. With or without specific protocol, eye banks reported considering water type (84%) and length of time submerged (92%) to determine eligibility. 22% of eye banks reported medical director involvement when eligibility determination was unclear. 79 tissues from 40 donors who were submerged were identified in 2014-2016 eye bank data. No donor tissues had pre-processing corneal infiltrates, positive rim cultures, or adverse events post-keratoplasty. Corneal epithelial integrity and ECD were not associated with water type or length of time submerged. In conclusion, data from a large eye bank network showed no adverse events or outcomes, indicating these tissues may be safe.
Cyclooxygenase-2 expression in the eyes of cats with and without uveitis.
Sim, Zhi Hui; Pinard, Chantale L; Plattner, Brandon L; Bienzle, Dorothee
2018-01-01
OBJECTIVE To characterize the distribution and intensity of cyclooxygenase (COX)-2 expression in the eyes of cats with and without uveitis and to determine whether COX-2 expression is correlated with severity of inflammation. SAMPLES Archived ocular tissue specimens from 51 cats with and 10 cats without ocular disease. PROCEDURES Specimens from only 1 eye were evaluated for each cat. Specimens were stained with H&E stain or immunohistochemical stain for detection of COX-2 and reviewed. For each eye, the type, severity, and distribution of inflammation and the distribution and intensity of COX-2 expression were determined for the uvea and other ocular tissues. Correlation between COX-2 expression and inflammation severity was also assessed. RESULTS COX-2 was not expressed in any nondiseased eye. Of the 51 diseased eyes, 20 had histologic evidence of lymphocytic-plasmacytic uveitis, 13 had neutrophilic uveitis, 11 had diffuse iris melanoma with uveitis, and 7 had diffuse iris melanoma without uveitis. Of the 44 eyes with uveitis, COX-2 was detected in the uvea of 16, including 11 eyes with lymphocytic-plasmacytic uveitis, 4 with neutrophilic uveitis, and 1 with diffuse iris melanoma-induced uveitis. Inflammation was severe, moderate, or mild in 10, 5, and 1 of those eyes, respectively. Cyclooxygenase-2 was detected in the cornea of 21 eyes with uveitis and 1 eye with diffuse iris melanoma without uveitis. Uveitis severity was positively correlated with COX-2 expression in both the uvea and cornea. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that COX-2 is an inflammatory mediator in feline uveitis but not diffuse iris melanoma.
Moreno-López, Bernardo; Escudero, Miguel; Estrada, Carmen
2002-01-01
Nitric oxide (NO) synthesis by prepositus hypoglossi (PH) neurons is necessary for the normal performance of horizontal eye movements. We have previously shown that unilateral injections of NO synthase (NOS) inhibitors into the PH nucleus of alert cats produce velocity imbalance without alteration of the eye position control, both during spontaneous eye movements and the vestibulo-ocular reflex (VOR). This NO effect is exerted on the dorsal PH neuropil, whose fibres increase their cGMP content when stimulated by NO. In an attempt to determine whether NO acts by modulation of a specific neurotransmission system, we have now compared the oculomotor effects of NOS inhibition with those produced by local blockade of glutamatergic, GABAergic or glycinergic receptors in the PH nucleus of alert cats. Both glutamatergic antagonists used, 2-amino-5-phosphonovaleric acid (APV) and 2,3-dihydro-6-nitro-7-sulphamoyl-benzo quinoxaline (NBQX), induced a nystagmus contralateral to that observed upon NOS inhibition, and caused exponential eye position drift. In contrast, bicuculline and strychnine induced eye velocity alterations similar to those produced by NOS inhibitors, suggesting that NO oculomotor effects were due to facilitation of some inhibitory input to the PH nucleus. To investigate the anatomical location of the putative NO target neurons, the retrograde tracer Fast Blue was injected in one PH nucleus, and the brainstem sections containing Fast Blue-positive neurons were stained with double immunohistochemistry for NO-sensitive cGMP and glutamic acid decarboxylase. GABAergic neurons projecting to the PH nucleus and containing NO-sensitive cGMP were found almost exclusively in the ipsilateral medial vestibular nucleus and marginal zone. The results suggest that the nitrergic PH neurons control their own firing rate by a NO-mediated facilitation of GABAergic afferents from the ipsilateral medial vestibular nucleus. This self-control mechanism could play an important role in the maintenance of the vestibular balance necessary to generate a stable and adequate eye position signal. PMID:11927688
Huang, Alex S.; Saraswathy, Sindhu; Dastiridou, Anna; Begian, Alan; Mohindroo, Chirayu; Tan, James C. H.; Francis, Brian A.; Hinton, David R.; Weinreb, Robert N.
2016-01-01
Purpose To assess the ability of trabecular micro-bypass stents to improve aqueous humor outflow (AHO) in regions initially devoid of AHO as assessed by aqueous angiography. Methods Enucleated human eyes (14 total from 7 males and 3 females [ages 52–84]) were obtained from an eye bank within 48 hours of death. Eyes were oriented by inferior oblique insertion, and aqueous angiography was performed with indocyanine green (ICG; 0.4%) or fluorescein (2.5%) at 10 mm Hg. With an angiographer, infrared and fluorescent images were acquired. Concurrent anterior segment optical coherence tomography (OCT) was performed, and fixable fluorescent dextrans were introduced into the eye for histologic analysis of angiographically positive and negative areas. Experimentally, some eyes (n = 11) first received ICG aqueous angiography to determine angiographic patterns. These eyes then underwent trabecular micro-bypass sham or stent placement in regions initially devoid of angiographic signal. This was followed by fluorescein aqueous angiography to query the effects. Results Aqueous angiography in human eyes yielded high-quality images with segmental patterns. Distally, angiographically positive but not negative areas demonstrated intrascleral lumens on OCT images. Aqueous angiography with fluorescent dextrans led to their trapping in AHO pathways. Trabecular bypass but not sham in regions initially devoid of ICG aqueous angiography led to increased aqueous angiography as assessed by fluorescein (P = 0.043). Conclusions Using sequential aqueous angiography in an enucleated human eye model system, regions initially without angiographic flow or signal could be recruited for AHO using a trabecular bypass stent. PMID:27588614
Eye structure and amphibious foraging in albatrosses
Martin, G. R.
1998-01-01
Anterior eye structure and retinal visual fields were determined in grey-headed and black-browed albatrosses, Diomedea melanophris and D. chrysostoma (Procellariiformes, Diomedeidae), using keratometry and an ophthalmoscopic reflex technique. Results for the two species were very similar and indicate that the eyes are of an amphibious optical design suggesting that albatross vision is well suited to the visual pursuit of active prey both on and below the ocean surface. The corneas are relatively flat (radius ca. 14.5 mm) and hence of low absolute refractive power (ca. 23 dioptres). In air the binocular fields are relatively long (vertical extent ca. 70 degrees) and narrow (maximum width in the plane of the optic axes 26–32 degrees), a topography found in a range of bird species that employ visual guidance of bill position when foraging. The cyclopean fields measure approximately 270 degrees in the horizontal plane, but there is a 60 degrees blind sector above the head owing to the positioning of the eyes below the protruding supraorbital ridges. Upon immersion the monocular fields decrease in width such that the binocular fields are abolished. Anterior eye structure, and visual field topography in both air and water, show marked similarity with those of the Humboldt penguin.
Golden proportion for maxillofacial surgery in Orientals.
Kawakami, S; Tsukada, S; Hayashi, H; Takada, Y; Koubayashi, S
1989-11-01
The facial position and balance of eyes, nose, and mouth in typical Japanese individuals were investigated, based on the golden proportion for each of these relationships. We found that Japanese tend to have a longer upper lip and shorter chin length compared with Caucasians. We believe that this tendency represents a general facial characteristic of the Oriental population. Each ratio obtained from determinations by our method was used for preoperative and postoperative aesthetic analysis in maxillofacial surgery. This method is considered useful because it permitted us to understand quantitatively the positional relationship and the balance of eyes, nose, and mouth in the face and to make comparisons with typical subjects.
Galbis-Estrada, Carmen; Pinazo-Durán, Maria D; Cantú-Dibildox, Jorge; Marco-Ramírez, Carla; Díaz-Llópis, Manuel; Benítez-del-Castillo, Javier
2013-01-01
Glaucoma and dry eye disorders (DEDs) are frequent comorbidities. The antioxidant and anti-inflammatory properties of essential polyunsaturated fatty acids have been extensively studied in relation to eye diseases. Our objective was to determine the effects of oral supplementation with a combined formulation of antioxidants and essential polyunsaturated fatty acids on expression of cytokines and chemokines in tears from patients with DEDs or primary open-angle glaucoma (POAG). Participants (n = 97) were distributed into three groups: (1) individuals with nonsevere DEDs (DEDG), (2) individuals with nonadvanced POAG (POAGG), and (3) healthy controls. These groups were randomized into two subgroups: one received a daily antioxidant and essential polyunsaturated fatty acid supplement (two pills) for 3 months (+S), and the other did not (-NS). Participants were interviewed and ophthalmologically examined. Concentrations of specific cytokines and chemokines in reflex tears were determined by multiplexed particle-based flow cytometry. The data were analyzed statistically (SPSS version 15.0). Comparison of the results from the DEDG and POAGG patients showed significant differences in tear expression of granulocyte-macrophage colony-stimulating factor (P = 0.008), tumor necrosis factor α (P = 0.005), vascular endothelial growth factor (P = 0.038), interleukin-4 (P = 0.030), and interleukin-6 (P = 0.044). The main signs and symptoms of dry eyes such as dryness, burning, photophobia, eye heaviness, and blurred vision, as well as positive changes in eyelashes, hair, nails and skin, were significantly improved in DEDG +S and POAGG +S patients relative to unsupplemented patients. Inflammation biomarkers were differentially expressed in glaucomatous tears, but the differences changed upon antioxidant/essential polyunsaturated fatty acid supplementation. Chronic instillation of antihypertensive eye drops must be considered for integrating protocols to glaucoma standards of care.
Eye Growth in Term- And Preterm-Born Eyes Modeled From Magnetic Resonance Images
Munro, Robert J.; Fulton, Anne B.; Chui, Toco Y. P.; Moskowitz, Anne; Ramamirtham, Ramkumar; Hansen, Ronald M.; Prabhu, Sanjay P.; Akula, James D.
2015-01-01
Purpose. We generated a model of eye growth and tested it against an eye known to develop abnormally, one with a history of retinopathy of prematurity (ROP). Methods. We reviewed extant magnetic resonance images (MRIs) from term and preterm-born patients for suitable images (n = 129). We binned subjects for analysis based upon postmenstrual age at birth (in weeks) and ROP history (“Term” ≥ 37, “Premature” ≤ 32 with no ROP, “ROP” ≤ 32 with ROP). We measured the axial positions and curvatures of the cornea, anterior and posterior lens, and inner retinal surface. We fit anterior chamber depth (ACD), posterior segment depth (PSD), axial length (AL), and corneal and lenticular curvatures with logistic growth curves that we then evaluated for significant differences. We also measured the length of rays from the centroid to the surface of the eye at 5° intervals, and described the length versus age relationship of each ray, Lray(x), using the same logistic growth curve. We determined the rate of ray elongation, Eray(x), from Lray dy/dx. Then, we estimated the scleral growth that accounted for Eray(x), G(x), at every age and position. Results. Relative to Term, development of ACD, PSD, AL, and corneal and lenticular curvatures was delayed in ROP eyes, but not Premature eyes. In Term infants, G(x) was fast and predominantly equatorial; in age-matched ROP eyes, maximal G(x) was offset by approximately 90°. Conclusions. We produced a model of normal eye growth in term-born subjects. Relative to normal, the ROP eye is characterized by delayed, abnormal growth. PMID:26024095
Fluctuation of Bacteria on Bleb Surface After Trabeculectomy With Adjunctive Mitomycin C.
Takahashi, Nobumichi; Sawada, Akira; Mochizuki, Kiyofumi; Katada, Toshihiko; Yamamoto, Tetsuya
2016-05-01
To determine whether the bacterial and floral patterns on the bleb surface are affected by the season in eyes that had undergone trabeculectomy with adjunctive mitomycin C. Forty-four glaucoma patients who had an avascular or a hypovascular cystic filtering bleb were studied. Swabs of the bleb surface were taken 4 times in 1 year. The samples were cultured, and all organisms isolated were identified and tested for antibiotic sensitivity and resistance. Of the 176 specimens, 48 tested positive in cultures. Out of the 44 glaucoma eyes that had undergone trabeculectomy, 30 (68.2%) eyes were culture positive. A total of 58 strains were isolated. The organisms isolated were 22 strains of Staphylococcus epidermidis, 21 strains of Propionibacterium acnes, 8 strains of Corynebacterium sp., 5 strains of Staphylococcus sp., and 1 strain of both Neisseria sp., and Candida parapsilosis. Fifteen eyes had a positive culture ≥2 times, and in 10 of these eyes, the same strain was isolated. There was no resistance to vancomycin by S. epidermidis, P. acnes, and Corynebacterium sp. All of the isolates of S.epidermidis were sensitive to minocycline and amikacin. The rate of bacterial detection in the spring was 13.6%, summer was 20.5%, autumn was 45.5%, and winter was 29.5%. The increase in the incidence of bacterial presence during autumn was significant (P=0.006; the Fisher exact probability test). It is not rare to detect the bacterial organisms on the bleb surface in glaucomatous eyes that had undergone trabeculectomy. The prevalence varied with the season and was highest in the autumn.
Arizpe, Joseph; Kravitz, Dwight J.; Yovel, Galit; Baker, Chris I.
2012-01-01
Fixation patterns are thought to reflect cognitive processing and, thus, index the most informative stimulus features for task performance. During face recognition, initial fixations to the center of the nose have been taken to indicate this location is optimal for information extraction. However, the use of fixations as a marker for information use rests on the assumption that fixation patterns are predominantly determined by stimulus and task, despite the fact that fixations are also influenced by visuo-motor factors. Here, we tested the effect of starting position on fixation patterns during a face recognition task with upright and inverted faces. While we observed differences in fixations between upright and inverted faces, likely reflecting differences in cognitive processing, there was also a strong effect of start position. Over the first five saccades, fixation patterns across start positions were only coarsely similar, with most fixations around the eyes. Importantly, however, the precise fixation pattern was highly dependent on start position with a strong tendency toward facial features furthest from the start position. For example, the often-reported tendency toward the left over right eye was reversed for the left starting position. Further, delayed initial saccades for central versus peripheral start positions suggest greater information processing prior to the initial saccade, highlighting the experimental bias introduced by the commonly used center start position. Finally, the precise effect of face inversion on fixation patterns was also dependent on start position. These results demonstrate the importance of a non-stimulus, non-task factor in determining fixation patterns. The patterns observed likely reflect a complex combination of visuo-motor effects and simple sampling strategies as well as cognitive factors. These different factors are very difficult to tease apart and therefore great caution must be applied when interpreting absolute fixation locations as indicative of information use, particularly at a fine spatial scale. PMID:22319606
Dooley, K O; Farmer, A
1988-08-01
Neurolinguistic programming's hypothesized eye movements were measured independently using videotapes of 10 nonfluent aphasic and 10 control subjects matched for age and sex. Chi-squared analysis indicated that eye-position responses were significantly different for the groups. Although earlier research has not supported the hypothesized eye positions for normal subjects, the present findings support the contention that eye-position responses may differ between neurologically normal and aphasic individuals.
A Compact Fiber Optic Eye Diagnostic System
NASA Technical Reports Server (NTRS)
Ansari, Rafat R.; Suh, Kwang I.; Dubin, Stephen; Dellavecchia, Michael A.
1995-01-01
A new fiber optic probe developed for determining transport properties of sub-micron particles in fluid experiments in a microgravity environment has been applied to study different parts of an eye. The probe positioned in front of an eye, delivers a low power (approximately few microW) light from a laser diode into the eye and guides the light which is back scattered by different components (aqueous humor, lens, and vitreous humor) of the eye through a receiving optical fiber to a photo detector. The probe provides rapid determination of macromolecular diffusivities and their respective size distributions in the eye lens and the gel-like materials in the vitreous humor. In a clinical setting, the probe can be mounted on a standard slit-lamp apparatus simply using a Hruby lens holder. The capability of detecting cataracts, both nuclear and cortical, in their early stages of formation, in a non invasive and quantitative fashion, has the potential in patient monitoring and in developing and testing new drugs or diet therapies to 'dissolve' or slow down the cataract formation before the surgery becomes necessary. The ability to detect biochemical and macromolecular changes in the vitreous structure can be very useful in identifying certain diseases of the posterior chamber and their complications, e.g., posterior vitreous detachment and diabetic retinopathy.
A Compact Fiber Optic Eye Diagnostics System
NASA Technical Reports Server (NTRS)
Ansari, Rafat R.; Suh, Kwang I.; DellaVecchia, Michael A.; Dubin, Stephen; Zigler, J. Samuel, Jr.
1995-01-01
A new fiber optic probe development for determining transport properties of sub-micron particles in fluids experiments in a microgravity environment has been applied to study different parts of the eye. The probe positioned in front of an eye, delivers a low power (approximately a few mu W) light from a laser diode into the eye and guides the light which is back scattered by different components (aqueous humor, lens, and vitreous humor) of the eye through a receiving optical fiber to a photo detector. The probe provides rapid determination of macromolecular diffusivities and their respective size distributions in the eye lens and the gel-like material in the vitreous humor. For a clinical use, the probe is mounted on a standard slit-lamp apparatus simply using Hruby lens holder. The capability of detecting cataracts, both nuclear and cortical, in their early stages of formation, in a non invasive and quantitative fashion, has the potential in patient monitoring and in developing and testing new drugs or diet therapies to 'dissolve' or slow down the cataract formation before the surgery becomes necessary. The ability to detect biochemical and macromolecular changes in the vitreous structure can be very useful in identifying certain diseases of the posterior chamber and their complications, e.g., posterior vitreous detachment and diabetic retinopathy.
[Influence of mechanical effect due to MRI-magnet on tattoo seal and eye makeup].
Morishita, Yuta; Miyati, Tosiaki; Ueda, Jousei; Shimizu, Mitsuru; Hamaguchi, Takashi; Fujiwara, Yasuhiro; Hayashi, Hiroyuki
2008-05-20
The purpose of our study was to assess the mechanical effect on tattoo seals and eye makeup caused by a spatial magnetic gradient in the magnetic resonance imaging (MRI) system. Seven kinds of tattoo seals and three kinds of eye makeup, i.e., mascara, eye shadow, and eyeliner were used. On a 3.0-Tesla MRI, we determined these deflection angles according to a method established by the American Society for Testing and Materials (ASTM) at the position that produced the greatest magnetically induced deflection. Eighty-five percent of the tattoo seals showed deflection angles greater than 45 degrees of the ASTM guidelines, and the mascara and eye shadow showed over 40 degrees. This was because these contained ferromagnetic pigments such as an iron oxide, but those translational forces were very small owing to slight mass. However, it is desirable that these should be removed before MRI examination to prevent secondary problems.
Labetoulle, Marc; Frau, Eric; Offret, Hervé; Nordmann, Patrice; Naas, Thierry
2002-08-01
Some anaesthetics inhibit bacterial growth, and thus may lead to low rates of positive cultures from bacterial keratitis. Antibacterial properties of lidocaine were compared with those of oxybuprocaine or tetracaine, either in current commercial eye lotions or in extemporaneous solutions. Forty-eight bacterial strains were used to determine the minimum inhibitory and bactericidal concentrations of four commercial eye lotions containing oxybuprocaine or tetracaine, of a non-ophthalmic 1% lidocaine commercial solution and of extemporaneously prepared solutions of oxybuprocaine, tetracaine, lidocaine and benzalkonium. Most strains had their growth inhibited by 0.2% oxybuprocaine or 0.4% tetracaine, which corresponds to a 1/2 dilution of the commercial eye-drops. Bacterial growth was still observed with a 1% lidocaine solution. Currently available anaesthetic eye-drops that are used before corneal specimen collection may lead to false-negative bacterial cultures. Conversely, a non-preserved 1% lidocaine solution might be more appropriate in corneal specimen collection.
Perceptual Calibration for Immersive Display Environments
Ponto, Kevin; Gleicher, Michael; Radwin, Robert G.; Shin, Hyun Joon
2013-01-01
The perception of objects, depth, and distance has been repeatedly shown to be divergent between virtual and physical environments. We hypothesize that many of these discrepancies stem from incorrect geometric viewing parameters, specifically that physical measurements of eye position are insufficiently precise to provide proper viewing parameters. In this paper, we introduce a perceptual calibration procedure derived from geometric models. While most research has used geometric models to predict perceptual errors, we instead use these models inversely to determine perceptually correct viewing parameters. We study the advantages of these new psychophysically determined viewing parameters compared to the commonly used measured viewing parameters in an experiment with 20 subjects. The perceptually calibrated viewing parameters for the subjects generally produced new virtual eye positions that were wider and deeper than standard practices would estimate. Our study shows that perceptually calibrated viewing parameters can significantly improve depth acuity, distance estimation, and the perception of shape. PMID:23428454
Eye contrast polarity is critical for face recognition by infants.
Otsuka, Yumiko; Motoyoshi, Isamu; Hill, Harold C; Kobayashi, Megumi; Kanazawa, So; Yamaguchi, Masami K
2013-07-01
Just as faces share the same basic arrangement of features, with two eyes above a nose above a mouth, human eyes all share the same basic contrast polarity relations, with a sclera lighter than an iris and a pupil, and this is unique among primates. The current study examined whether this bright-dark relationship of sclera to iris plays a critical role in face recognition from early in development. Specifically, we tested face discrimination in 7- and 8-month-old infants while independently manipulating the contrast polarity of the eye region and of the rest of the face. This gave four face contrast polarity conditions: fully positive condition, fully negative condition, positive face with negated eyes ("negative eyes") condition, and negated face with positive eyes ("positive eyes") condition. In a familiarization and novelty preference procedure, we found that 7- and 8-month-olds could discriminate between faces only when the contrast polarity of the eyes was preserved (positive) and that this did not depend on the contrast polarity of the rest of the face. This demonstrates the critical role of eye contrast polarity for face recognition in 7- and 8-month-olds and is consistent with previous findings for adults. Copyright © 2013 Elsevier Inc. All rights reserved.
Kinematics of Visually-Guided Eye Movements
Hess, Bernhard J. M.; Thomassen, Jakob S.
2014-01-01
One of the hallmarks of an eye movement that follows Listing’s law is the half-angle rule that says that the angular velocity of the eye tilts by half the angle of eccentricity of the line of sight relative to primary eye position. Since all visually-guided eye movements in the regime of far viewing follow Listing’s law (with the head still and upright), the question about its origin is of considerable importance. Here, we provide theoretical and experimental evidence that Listing’s law results from a unique motor strategy that allows minimizing ocular torsion while smoothly tracking objects of interest along any path in visual space. The strategy consists in compounding conventional ocular rotations in meridian planes, that is in horizontal, vertical and oblique directions (which are all torsion-free) with small linear displacements of the eye in the frontal plane. Such compound rotation-displacements of the eye can explain the kinematic paradox that the fixation point may rotate in one plane while the eye rotates in other planes. Its unique signature is the half-angle law in the position domain, which means that the rotation plane of the eye tilts by half-the angle of gaze eccentricity. We show that this law does not readily generalize to the velocity domain of visually-guided eye movements because the angular eye velocity is the sum of two terms, one associated with rotations in meridian planes and one associated with displacements of the eye in the frontal plane. While the first term does not depend on eye position the second term does depend on eye position. We show that compounded rotation - displacements perfectly predict the average smooth kinematics of the eye during steady- state pursuit in both the position and velocity domain. PMID:24751602
Reliability of corneal dynamic scheimpflug analyser measurements in virgin and post-PRK eyes.
Chen, Xiangjun; Stojanovic, Aleksandar; Hua, Yanjun; Eidet, Jon Roger; Hu, Di; Wang, Jingting; Utheim, Tor Paaske
2014-01-01
To determine the measurement reliability of CorVis ST, a dynamic Scheimpflug analyser, in virgin and post-photorefractive keratectomy (PRK) eyes and compare the results between these two groups. Forty virgin eyes and 42 post-PRK eyes underwent CorVis ST measurements performed by two technicians. Repeatability was evaluated by comparing three consecutive measurements by technician A. Reproducibility was determined by comparing the first measurement by technician A with one performed by technician B. Intraobserver and interobserver intraclass correlation coefficients (ICCs) were calculated. Univariate analysis of covariance (ANCOVA) was used to compare measured parameters between virgin and post-PRK eyes. The intraocular pressure (IOP), central corneal thickness (CCT) and 1st applanation time demonstrated good intraobserver repeatability and interobserver reproducibility (ICC ≧ 0.90) in virgin and post-PRK eyes. The deformation amplitude showed a good or close to good repeatability and reproducibility in both groups (ICC ≧ 0.88). The CCT correlated positively with 1st applanation time (r = 0.437 and 0.483, respectively, p<0.05) and negatively with deformation amplitude (r = -0.384 and -0.375, respectively, p<0.05) in both groups. Compared to post-PRK eyes, virgin eyes showed longer 1st applanation time (7.29 ± 0.21 vs. 6.96 ± 0.17 ms, p<0.05) and lower deformation amplitude (1.06 ± 0.07 vs. 1.17 ± 0.08 mm, p < 0.05). CorVis ST demonstrated reliable measurements for CCT, IOP, and 1st applanation time, as well as relatively reliable measurement for deformation amplitude in both virgin and post-PRK eyes. There were differences in 1st applanation time and deformation amplitude between virgin and post-PRK eyes, which may reflect corneal biomechanical changes occurring after the surgery in the latter.
Kasten, Erich; Bunzenthal, Ulrike; Sabel, Bernhard A
2006-11-25
It has been argued that patients with visual field defects compensate for their deficit by making more frequent eye movements toward the hemianopic field and that visual field enlargements found after vision restoration therapy (VRT) may be an artefact of such eye movements. In order to determine if this was correct, we recorded eye movements in hemianopic subjects before and after VRT. Visual fields were measured in subjects with homonymous visual field defects (n=15) caused by trauma, cerebral ischemia or haemorrhage (lesion age >6 months). Visual field charts were plotted using both high-resolution perimetry (HRP) and conventional perimetry before and after a 3-month period of VRT, with eye movements being recorded with a 2D-eye tracker. This permitted quantification of eye positions and measurements of deviation from fixation. VRT lead to significant visual field enlargements as indicated by an increase of stimulus detection of 3.8% when tested using HRP and about 2.2% (OD) and 3.5% (OS) fewer misses with conventional perimetry. Eye movements were expressed as the standard deviations (S.D.) of the eye position recordings from fixation. Before VRT, the S.D. was +/-0.82 degrees horizontally and +/-1.16 degrees vertically; after VRT, it was +/-0.68 degrees and +/-1.39 degrees , respectively. A cluster analysis of the horizontal eye movements before VRT showed three types of subjects with (i) small (n=7), (ii) medium (n=7) or (iii) large fixation instability (n=1). Saccades were directed equally to the right or the left side; i.e., with no preference toward the blind hemifield. After VRT, many subjects showed a smaller variability of horizontal eye movements. Before VRT, 81.6% of the recorded eye positions were found within a range of 1 degrees horizontally from fixation, whereas after VRT, 88.3% were within that range. In the 2 degrees range, we found 94.8% before and 98.9% after VRT. Subjects moved their eyes 5 degrees or more 0.3% of the time before VRT versus 0.1% after VRT. Thus, in this study, subjects with homonymous visual field defects who were attempting to fixate a central target while their fields were being plotted, typically showed brief horizontal shifts with no preference toward or away from the blind hemifield. These eye movements were usually less than 1 degrees from fixation. Large saccades toward the blind field after VRT were very rare. VRT has no effect on either the direction or the amplitude of horizontal eye movements during visual field testing. These results argue against the theory that the visual field enlargements are artefacts induced by eye movements.
Asymmetric Corneal Flattening Effect After Small Incision Cataract Surgery.
Alpins, Noel; Ong, James K Y; Stamatelatos, George
2016-08-01
To determine whether the flattening effect of corneal incisions differs between the right and left eye. A retrospective study of preoperative and postoperative corneal astigmatism was performed for patients who had bilateral cataract surgery by a right-handed surgeon. The change in corneal astigmatism was attributed to the 2.2-mm phacoemulsification incision, and the incisional flattening effect was calculated. The incisions were grouped by position on the eye and whether they were performed on the preoperative steep corneal meridian. A total of 1,298 eyes of 649 patients were evaluated. The flattening effect of temporal 2.2-mm incisions performed on the preoperative corneal steep meridian was different for right eyes (0.53 diopters [D]) and left eyes (0.34 D) (P = .017). The flattening effect of superior 2.2-mm incisions performed on the preoperative corneal steep meridian was equivalent in the two eyes. The flattening effect of a corneal incision may depend on whether it has been performed on the right or the left eye. [J Refract Surg. 2016;32(9):598-603.]. Copyright 2016, SLACK Incorporated.
Gonzales, John A; Chou, Annie; Rose-Nussbaumer, Jennifer R; Bunya, Vatinee Y; Criswell, Lindsey A; Shiboski, Caroline H; Lietman, Thomas M
2018-07-01
To determine whether ocular phenotypic features of keratoconjunctivitis sicca (KCS) and/or participant-reported symptoms of dry eye disease are associated with depression in women participants enrolled in the Sjögren's International Collaborative Clinical Alliance (SICCA). Cross-sectional study. Women enrolled in the SICCA registry from 9 international research sites. Participants met at least 1 of 5 inclusion criteria for registry enrollment (including complaints of dry eyes or dry mouth, a previous diagnosis of Sjögren syndrome (SS), abnormal serology (positive anti-Sjögren syndrome antigen A and/or B [anti-SSA and/or anti-SSB]), or elevated antinuclear antibody and rheumatoid factor), bilateral parotid gland enlargement, or multiple dental caries). At baseline, participants had oral, ocular, and rheumatologic examination; blood and saliva collection; and a labial salivary gland biopsy (LSGB). They also completed an interview and questionnaires including assessment of depression with the Patient Health Questionnaire 9 (PHQ-9). Univariate logistic regression was used to assess the association between depression and demographic characteristics, participant-reported health, phenotypic features of Sjögren syndrome, and participant-reported symptoms. Mixed-effects modeling was performed to determine if phenotypic features of KCS and/or participant-reported symptoms of dry eye disease were associated with depression, controlling for health, age, country or residence, and sex and allowing for nonindependence within geographic site. Dry eye complaints produced a 1.82-fold (95% confidence interval [CI] 1.38-2.40) higher odds of having depression compared to being symptom-free (P < .001). Additionally, complaints of specific ocular sensations were associated with a higher odds of depression including burning sensation (odds ratio 2.25, 95% CI 1.87-2.72, P < .001) compared to those without complaints. In both women with and without SS, the presence of symptoms of dry eyes and/or dry mouth rather than SS itself resulted in higher odds of depression. One particular ocular phenotypic feature of SS, a positive ocular staining score, was inversely correlated with depression. Participant-reported eye symptoms, particularly specific ocular sensations such as burning, were found to be positively associated with individual American College of Rheumatology/EUropean League Against Rheumatism (ACR/EULAR) SS criteria items. Copyright © 2018 Elsevier Inc. All rights reserved.
In vitro eye corrosion study of agrochemicals on isolated chicken eye.
Buda, I; Budai, P; Szabó, R; Lehel, J
2013-01-01
Agrochemicals must undergo numberless toxicological tests before marketing. The eye irritation test is part of this test packet. Nowadays, OECD 405 can be used to classify the irritation potential of substances, the base of the OECD 405 guideline is the Draize test, which is one of the most criticized in vivo methods because of the injuries of the test animals and subjective nature of the test in recording the results. Therefore, several in vitro tests have been developed to replace totally or partly the in vivo eye irritation testing. The isolated chicken eye test method (OECD 438), which was used, is one of these alternative methods. Five different agrochemicals were examined in the following way: All test compounds were applied in a single dose onto the cornea of isolated chicken eyes in order to potentially classify the test compounds as ocular corrosive and/or severe irritant. The damages caused by the test substances were assessed by the determination of corneal swelling, opacity, fluorescein retention and morphological effects. These parameters were evaluated pre-treatment and starting at approximately 30, 75, 120, 180, and 240 minutes after the post-treatment rinse. The endpoints evaluated were corneal opacity, swelling, fluorescein retention and morphological effects. All of the endpoints, with the exception of fluorescein retention (which was determined only at pre-treatment and 30 minutes after test substance exposure) were determined at each of the above time points. Positive and negative controls were used and they showed the expected results in each study. In these in vitro eye corrosives and severe irritants studies, using the Isolated Chicken Eye model with five different products, no ocular corrosion or severe irritation potential were observed. These results correspond to the available information about the tested agrochemicals, so these studies with isolated chicken eye are considered to be successful.
Predictive performance of the Vitrigel‐eye irritancy test method using 118 chemicals
Yamaguchi, Hiroyuki; Kojima, Hajime
2015-01-01
Abstract We recently developed a novel Vitrigel‐eye irritancy test (EIT) method. The Vitrigel‐EIT method is composed of two parts, i.e., the construction of a human corneal epithelium (HCE) model in a collagen vitrigel membrane chamber and the prediction of eye irritancy by analyzing the time‐dependent profile of transepithelial electrical resistance values for 3 min after exposing a chemical to the HCE model. In this study, we estimated the predictive performance of Vitrigel‐EIT method by testing a total of 118 chemicals. The category determined by the Vitrigel‐EIT method in comparison to the globally harmonized system classification revealed that the sensitivity, specificity and accuracy were 90.1%, 65.9% and 80.5%, respectively. Here, five of seven false‐negative chemicals were acidic chemicals inducing the irregular rising of transepithelial electrical resistance values. In case of eliminating the test chemical solutions showing pH 5 or lower, the sensitivity, specificity and accuracy were improved to 96.8%, 67.4% and 84.4%, respectively. Meanwhile, nine of 16 false‐positive chemicals were classified irritant by the US Environmental Protection Agency. In addition, the disappearance of ZO‐1, a tight junction‐associated protein and MUC1, a cell membrane‐spanning mucin was immunohistologically confirmed in the HCE models after exposing not only eye irritant chemicals but also false‐positive chemicals, suggesting that such false‐positive chemicals have an eye irritant potential. These data demonstrated that the Vitrigel‐EIT method could provide excellent predictive performance to judge the widespread eye irritancy, including very mild irritant chemicals. We hope that the Vitrigel‐EIT method contributes to the development of safe commodity chemicals. Copyright © 2015 The Authors. Journal of Applied Toxicology published by John Wiley & Sons Ltd. PMID:26472347
Rahal, Miguel Antônio; Alonso, Angélica Castilho; Andrusaitis, Felix Ricardo; Rodrigues, Thuam Silva; Speciali, Danielli Souza; Greve, Júlia Maria D′Andréa; Leme, Luiz Eugênio Garcez
2015-01-01
OBJECTIVE: To determine whether Tai Chi Chuan or ballroom dancing promotes better performance with respect to postural balance, gait, and postural transfer among elderly people. METHODS: We evaluated 76 elderly individuals who were divided into two groups: the Tai Chi Chuan Group and the Dance Group. The subjects were tested using the NeuroCom Balance Master® force platform system with the following protocols: static balance tests (the Modified Clinical Tests of Sensory Interaction on Balance and Unilateral Stance) and dynamic balance tests (the Walk Across Test and Sit-to-stand Transfer Test). RESULTS: In the Modified Clinical Test of Sensory Interaction on Balance, the Tai Chi Chuan Group presented a lower sway velocity on a firm surface with open and closed eyes, as well as on a foam surface with closed eyes. In the Modified Clinical Test of Sensory Interaction on Unilateral Stance, the Tai Chi Chuan Group presented a lower sway velocity with open eyes, whereas the Dance Group presented a lower sway velocity with closed eyes. In the Walk Across Test, the Tai Chi Chuan Group presented faster walking speeds than those of the Dance Group. In the Sit-to-stand Transfer Test, the Tai Chi Chuan Group presented shorter transfer times from the sitting to the standing position, with less sway in the final standing position. CONCLUSION: The elderly individuals who practiced Tai Chi Chuan had better bilateral balance with eyes open on both types of surfaces compared with the Dance Group. The Dance Group had better unilateral postural balance with eyes closed. The Tai Chi Chuan Group had faster walking speeds, shorter transfer times, and better postural balance in the final standing position during the Sit-to-stand Test. PMID:26017644
Rahal, Miguel Antônio; Alonso, Angélica Castilho; Andrusaitis, Felix Ricardo; Rodrigues, Thuam Silva; Speciali, Danielli Souza; Greve, Júlia Maria D Andréa; Leme, Luiz Eugênio Garcez
2015-03-01
To determine whether Tai Chi Chuan or ballroom dancing promotes better performance with respect to postural balance, gait, and postural transfer among elderly people. We evaluated 76 elderly individuals who were divided into two groups: the Tai Chi Chuan Group and the Dance Group. The subjects were tested using the NeuroCom Balance Master¯ force platform system with the following protocols: static balance tests (the Modified Clinical Tests of Sensory Interaction on Balance and Unilateral Stance) and dynamic balance tests (the Walk Across Test and Sit-to-stand Transfer Test). In the Modified Clinical Test of Sensory Interaction on Balance, the Tai Chi Chuan Group presented a lower sway velocity on a firm surface with open and closed eyes, as well as on a foam surface with closed eyes. In the Modified Clinical Test of Sensory Interaction on Unilateral Stance, the Tai Chi Chuan Group presented a lower sway velocity with open eyes, whereas the Dance Group presented a lower sway velocity with closed eyes. In the Walk Across Test, the Tai Chi Chuan Group presented faster walking speeds than those of the Dance Group. In the Sit-to-stand Transfer Test, the Tai Chi Chuan Group presented shorter transfer times from the sitting to the standing position, with less sway in the final standing position. The elderly individuals who practiced Tai Chi Chuan had better bilateral balance with eyes open on both types of surfaces compared with the Dance Group. The Dance Group had better unilateral postural balance with eyes closed. The Tai Chi Chuan Group had faster walking speeds, shorter transfer times, and better postural balance in the final standing position during the Sit-to-stand Test.
Populin, Luis C; Tollin, Daniel J; Yin, Tom C T
2004-10-01
We examined the motor error hypothesis of visual and auditory interaction in the superior colliculus (SC), first tested by Jay and Sparks in the monkey. We trained cats to direct their eyes to the location of acoustic sources and studied the effects of eye position on both the ability of cats to localize sounds and the auditory responses of SC neurons with the head restrained. Sound localization accuracy was generally not affected by initial eye position, i.e., accuracy was not proportionally affected by the deviation of the eyes from the primary position at the time of stimulus presentation, showing that eye position is taken into account when orienting to acoustic targets. The responses of most single SC neurons to acoustic stimuli in the intact cat were modulated by eye position in the direction consistent with the predictions of the "motor error" hypothesis, but the shift accounted for only two-thirds of the initial deviation of the eyes. However, when the average horizontal sound localization error, which was approximately 35% of the target amplitude, was taken into account, the magnitude of the horizontal shifts in the SC auditory receptive fields matched the observed behavior. The modulation by eye position was not due to concomitant movements of the external ears, as confirmed by recordings carried out after immobilizing the pinnae of one cat. However, the pattern of modulation after pinnae immobilization was inconsistent with the observations in the intact cat, suggesting that, in the intact animal, information about the position of the pinnae may be taken into account.
Chan, Tommy C Y; Ye, Cong; Chan, Kwok Ping; Chu, Kai On; Jhanji, Vishal
2016-09-01
To evaluate the performance of a point-of-care test for detection of matrix metalloproteinase 9 (MMP-9) levels in post-laser-assisted in situ keratomileusis (LASIK) dry eyes. A comparative study between patients with mild to moderate post-LASIK dry eyes and age-matched normal subjects was conducted. Ocular surface disease index (OSDI), tear break-up time (TBUT), and tear film MMP-9 and total protein levels were compared between the two groups. A point-of-care test device (RPS InflammaDry, Sarasota, Florida, USA) was utilised to confirm elevated MMP-9 levels in tear film. Fourteen post-LASIK dry eyes and 34 normal eyes were included. There was no significant difference in age and gender between both groups (p>0.175). The OSDI was significantly higher (25.5±7.7 vs 7.4±2.5; p<0.001) and TBUT levels were significantly lower (5.4±0.9 vs 13.5±2.3; p<0.001) in patients with dry eye compared with normal subjects. The tear film MMP-9 levels were 52.7±32.5 ng/mL in dry eyes and 4.1±2.1 ng/mL in normal eyes (p<0.001). MMP-9 levels were >40 ng/mL in 7/14 (50.0%) post-LASIK dry eyes. The InflammaDry was positive in 8/14 (57.1%) post-LASIK eyes. All positive cases had tear film MMP-9 levels ≥38.03 ng/mL. Agreement between InflammaDry and MMP-9 was excellent with Cohen κ value of 0.857 in post-LASIK dry eyes. Only half of post-LASIK dry eyes were found to have significant inflammation associated with elevated MMP-9. The OSDI is useful to non-specifically identify patients with symptomatic dry eye while the InflammaDry determined which patients with dry eye were associated with significant inflammation that may guide therapeutic management decisions. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Test of the neurolinguistic programming hypothesis that eye-movements relate to processing imagery.
Wertheim, E H; Habib, C; Cumming, G
1986-04-01
Bandler and Grinder's hypothesis that eye-movements reflect sensory processing was examined. 28 volunteers first memorized and then recalled visual, auditory, and kinesthetic stimuli. Changes in eye-positions during recall were videotaped and categorized by two raters into positions hypothesized by Bandler and Grinder's model to represent visual, auditory, and kinesthetic recall. Planned contrast analyses suggested that visual stimulus items, when recalled, elicited significantly more upward eye-positions and stares than auditory and kinesthetic items. Auditory and kinesthetic items, however, did not elicit more changes in eye-position hypothesized by the model to represent auditory and kinesthetic recall, respectively.
Coordinated Flexibility: How Initial Gaze Position Modulates Eye-Hand Coordination and Reaching
ERIC Educational Resources Information Center
Adam, Jos J.; Buetti, Simona; Kerzel, Dirk
2012-01-01
Reaching to targets in space requires the coordination of eye and hand movements. In two experiments, we recorded eye and hand kinematics to examine the role of gaze position at target onset on eye-hand coordination and reaching performance. Experiment 1 showed that with eyes and hand aligned on the same peripheral start location, time lags…
Nakanishi, Hideo; Akagi, Tadamichi; Hangai, Masanori; Kimura, Yugo; Suda, Kenji; Kumagai, Kyoko Kawashima; Morooka, Satoshi; Ikeda, Hanako Ohashi; Yoshimura, Nagahisa
2015-07-01
We aimed to determine the sensitivity and specificity of the normative database of non-myopic and highly myopic eyes of the macular ganglion cell complex (mGCC) thickness embedded in the NIDEK RS-3000 spectral-domain optical coherence tomography (SD-OCT) for detecting early glaucoma in highly myopic eyes. Forty-seven highly myopic eyes (axial length ≥26.0 mm) of 47 subjects were studied. The SD-OCT images were used to determine the mGCC thickness within a 9-mm diameter circle centered on the fovea. The sensitivity and specificity of the non-myopic database were compared to that of the highly myopic database for distinguishing the early glaucomatous eyes from the non-glaucomatous eyes. The mGCC scans were classified as abnormal if at least one of the eight sectors of the significance map was < 1 % of the normative thickness. Twenty-one eyes were diagnosed to be non-glaucomatous and 26 eyes to have early glaucoma. . The average mGCC thickness was significantly thinner (80.9 ± 8.5 μm) in the early glaucoma group than in the non-glaucomatous group (91.2 ± 7.5 μm; p <1 × 10(-4)). The sensitivity was 96.2 % and specificity was 47.6 % when the non-myopic database was used, and the sensitivity was 92.3 % and the specificity was 90.5 % when the highly myopic database was used. The difference in the specificity was significant (p < 0.01). The significantly higher specificity of the myopic normative database for detecting early glaucoma in highly myopic eyes will lead to fewer false positive diagnoses. The database obtained from highly myopic eyes should be used when evaluating the mGCC thickness of highly myopic eyes.
NASA Technical Reports Server (NTRS)
Hess, B. J.; Angelaki, D. E.
1997-01-01
The kinematic constraints of three-dimensional eye positions were investigated in rhesus monkeys during passive head and body rotations relative to gravity. We studied fast and slow phase components of the vestibulo-ocular reflex (VOR) elicited by constant-velocity yaw rotations and sinusoidal oscillations about an earth-horizontal axis. We found that the spatial orientation of both fast and slow phase eye positions could be described locally by a planar surface with torsional variation of <2.0 +/- 0.4 degrees (displacement planes) that systematically rotated and/or shifted relative to Listing's plane. In supine/prone positions, displacement planes pitched forward/backward; in left/right ear-down positions, displacement planes were parallel shifted along the positive/negative torsional axis. Dynamically changing primary eye positions were computed from displacement planes. Torsional and vertical components of primary eye position modulated as a sinusoidal function of head orientation in space. The torsional component was maximal in ear-down positions and approximately zero in supine/prone orientations. The opposite was observed for the vertical component. Modulation of the horizontal component of primary eye position exhibited a more complex dependence. In contrast to the torsional component, which was relatively independent of rotational speed, modulation of the vertical and horizontal components of primary position depended strongly on the speed of head rotation (i.e., on the frequency of oscillation of the gravity vector component): the faster the head rotated relative to gravity, the larger was the modulation. Corresponding results were obtained when a model based on a sinusoidal dependence of instantaneous displacement planes (and primary eye position) on head orientation relative to gravity was fitted to VOR fast phase positions. When VOR fast phase positions were expressed relative to primary eye position estimated from the model fits, they were confined approximately to a single plane with a small torsional standard deviation ( approximately 1.4-2.6 degrees). This reduced torsional variation was in contrast to the large torsional spread (well >10-15 degrees ) of fast phase positions when expressed relative to Listing's plane. We conclude that primary eye position depends dynamically on head orientation relative to space rather than being fixed to the head. It defines a gravity-dependent coordinate system relative to which the torsional variability of eye positions is minimized even when the head is moved passively and vestibulo-ocular reflexes are evoked. In this general sense, Listing's law is preserved with respect to an otolith-controlled reference system that is defined dynamically by gravity.
Murray, Nicholas P.; Hunfalvay, Melissa; Bolte, Takumi
2017-01-01
Purpose The purpose of this study was to determine the reliability of interpupillary distance (IPD) and pupil diameter (PD) measures using an infrared eye tracker and central point stimuli. Validity of the test compared to known clinical tools was determined, and normative data was established against which individuals can measure themselves. Methods Participants (416) across various demographics were examined for normative data. Of these, 50 were examined for reliability and validity. Validity for IPD measured the test (RightEye IPD/PD) against the PL850 Pupilometer and the Essilor Digital CRP. For PD, the test was measured against the Rosenbaum Pocket Vision Screener (RPVS). Reliability was analyzed with intraclass correlation coefficients (ICC) between trials with Cronbach's alpha (CA) and the standard error of measurement for each ICC. Convergent validity was investigated by calculating the bivariate correlation coefficient. Results Reliability results were strong (CA > 0.7) for all measures. High positive significant correlations were found between the RightEye IPD test and the PL850 Pupilometer (P < 0.001) and Essilor Digital CRP (P < 0.001) and for the RightEye PD test and the RPVS (P < 0.001). Conclusions Using infrared eye tracking and the RightEye IPD/PD test stimuli, reliable and accurate measures of IPD and PD were found. Results from normative data showed an adequate comparison for people with normal vision development. Translational Relevance Results revealed a central point of fixation may remove variability in examining PD reliably using infrared eye tracking when consistent environmental and experimental procedures are conducted. PMID:28685104
Pax6 in Collembola: Adaptive Evolution of Eye Regression
Hou, Ya-Nan; Li, Sheng; Luan, Yun-Xia
2016-01-01
Unlike the compound eyes in insects, collembolan eyes are comparatively simple: some species have eyes with different numbers of ocelli (1 + 1 to 8 + 8), and some species have no apparent eye structures. Pax6 is a universal master control gene for eye morphogenesis. In this study, full-length Pax6 cDNAs, Fc-Pax6 and Cd-Pax6, were cloned from an eyeless collembolan (Folsomia candida, soil-dwelling) and an eyed one (Ceratophysella denticulata, surface-dwelling), respectively. Their phylogenetic positions are between the two Pax6 paralogs in insects, eyeless (ey) and twin of eyeless (toy), and their protein sequences are more similar to Ey than to Toy. Both Fc-Pax6 and Cd-Pax6 could induce ectopic eyes in Drosophila, while Fc-Pax6 exhibited much weaker transactivation ability than Cd-Pax6. The C-terminus of collembolan Pax6 is indispensable for its transactivation ability, and determines the differences of transactivation ability between Fc-Pax6 and Cd-Pax6. One of the possible reasons is that Fc-Pax6 accumulated more mutations at some key functional sites of C-terminus under a lower selection pressure on eye development due to the dark habitats of F. candida. The composite data provide a first molecular evidence for the monophyletic origin of collembolan eyes, and indicate the eye degeneration of collembolans is caused by adaptive evolution. PMID:26856893
Bruchmann, Iris; Szermerski, Bastian; Behrens, Rolf; Geworski, Lilli
2016-12-01
The human eye lens appears to be more radiosensitive than previously assumed. The reduction of the limit for the dose to the lens of the eye to 20 mSv per year has been passed in the current Euratom Directives (2013). Therefore, in this work the impact of laboratory glasses and X-ray protective goggles was investigated and reciprocal attenuation factors (i.e. transmission factors) for different nuclides (Tc-99m, I-131, Y-90, F-18 and Ga-68) were determined. The radionuclides in typical geometry (syringe, applicator) were positioned at a distance of 50 cm to the eyes of four Alderson-Head-Phantoms. Different dosemeters measuring H p (3) respective H p (0.07) were fixed to the eyes of the phantoms, either behind the glasses or without any protection means, respectively. The mean reciprocal attenuation factors were determined to be between unity for F-18 and I-131 using laboratory glasses (no attenuation effect) and < 0.01 for Y-90 using X-ray protective goggles. All other results were between these extremes. It has been shown, that prospective doses to the lens of the eye can be reduced significantly by using appropriate radiation protection means, especially for those dose-relevant beta radiation emitting nuclides such as Y-90. Copyright © 2015. Published by Elsevier GmbH.
MR-eyetracker: a new method for eye movement recording in functional magnetic resonance imaging.
Kimmig, H; Greenlee, M W; Huethe, F; Mergner, T
1999-06-01
We present a method for recording saccadic and pursuit eye movements in the magnetic resonance tomograph designed for visual functional magnetic resonance imaging (fMRI) experiments. To reliably classify brain areas as pursuit or saccade related it is important to carefully measure the actual eye movements. For this purpose, infrared light, created outside the scanner by light-emitting diodes (LEDs), is guided via optic fibers into the head coil and onto the eye of the subject. Two additional fiber optical cables pick up the light reflected by the iris. The illuminating and detecting cables are mounted in a plastic eyepiece that is manually lowered to the level of the eye. By means of differential amplification, we obtain a signal that covaries with the horizontal position of the eye. Calibration of eye position within the scanner yields an estimate of eye position with a resolution of 0.2 degrees at a sampling rate of 1000 Hz. Experiments are presented that employ echoplanar imaging with 12 image planes through visual, parietal and frontal cortex while subjects performed saccadic and pursuit eye movements. The distribution of BOLD (blood oxygen level dependent) responses is shown to depend on the type of eye movement performed. Our method yields high temporal and spatial resolution of the horizontal component of eye movements during fMRI scanning. Since the signal is purely optical, there is no interaction between the eye movement signals and the echoplanar images. This reasonably priced eye tracker can be used to control eye position and monitor eye movements during fMRI.
Schulze, S; Nietgen, G; Sekundo, W
2004-07-01
The aim of this study was to determine and compare the rate of eccentric laser ablation after LASIK depending on the eye tracker ring used. All LASIK treatments were carried out using the MEL-70 flying spot excimer laser (Zeiss-Meditec, Jena). The flap was produced using a Corneal Shaper trade mark or Hansatome trade mark Microkeratome (B and L Surgical, Heidelberg). Initially we used an 11 mm eye tracker ring without hinge protector. At the end of February 2001 this ring was replaced by a 10 mm and a 9.5 mm ring with built-in hinge protector. An additional modification was introduced by us: at 1 mm separations little teeth-like spikes were engraved into the eyeward side of the ring, thus stabilising the position of the ring on the globe and allowing free liquid to flow through the spaces between each spike. The built-in calibration system of the corneal topography (TMS 3, Tomey, Erlangen) from patients with a follow-up of one month or longer was used to determine the distance between the centre of the ablation zone from the fixation point. In group I patients (old ring) 42 eyes were treated. In 4 eyes ablation was perfect, in 21 eyes the ablation centre was located 0.1 to 0.49 mm from the fixation point, in 11 eyes 0.51 to 0.99 mm and in 5 eyes 1.1 to 1.49 mm whereas one eye showed a decentred ablation of 1.53 mm. In group II (new ring) 42 eyes were investigated also. In 11 eyes ablation was perfect, in 20 eyes the ablation centre was located 0.1 to 0.49 mm from the fixation point, in 10 eyes 0.5 to 0.99 mm and one eye had an eccentric ablation of 1.28 mm from the fixation point. The further development of our eye tracker ring for the MEL-70 laser considerably reduced the rate of decentred ablations. An enhanced grip of the ring onto the globe reduces a slow slide during the laser procedure.
Thurtell, M J; Black, R A; Halmagyi, G M; Curthoys, I S; Aw, S T
1999-05-01
Vertical eye position-dependence of the human vestibuloocular reflex during passive and active yaw head rotations. The effect of vertical eye-in-head position on the compensatory eye rotation response to passive and active high acceleration yaw head rotations was examined in eight normal human subjects. The stimuli consisted of brief, low amplitude (15-25 degrees ), high acceleration (4,000-6,000 degrees /s2) yaw head rotations with respect to the trunk (peak velocity was 150-350 degrees /s). Eye and head rotations were recorded in three-dimensional space using the magnetic search coil technique. The input-output kinematics of the three-dimensional vestibuloocular reflex (VOR) were assessed by finding the difference between the inverted eye velocity vector and the head velocity vector (both referenced to a head-fixed coordinate system) as a time series. During passive head impulses, the head and eye velocity axes aligned well with each other for the first 47 ms after the onset of the stimulus, regardless of vertical eye-in-head position. After the initial 47-ms period, the degree of alignment of the eye and head velocity axes was modulated by vertical eye-in-head position. When fixation was on a target 20 degrees up, the eye and head velocity axes remained well aligned with each other. However, when fixation was on targets at 0 and 20 degrees down, the eye velocity axis tilted forward relative to the head velocity axis. During active head impulses, the axis tilt became apparent within 5 ms of the onset of the stimulus. When fixation was on a target at 0 degrees, the velocity axes remained well aligned with each other. When fixation was on a target 20 degrees up, the eye velocity axis tilted backward, when fixation was on a target 20 degrees down, the eye velocity axis tilted forward. The findings show that the VOR compensates very well for head motion in the early part of the response to unpredictable high acceleration stimuli-the eye position- dependence of the VOR does not become apparent until 47 ms after the onset of the stimulus. In contrast, the response to active high acceleration stimuli shows eye position-dependence from within 5 ms of the onset of the stimulus. A model using a VOR-Listing's law compromise strategy did not accurately predict the patterns observed in the data, raising questions about how the eye position-dependence of the VOR is generated. We suggest, in view of recent findings, that the phenomenon could arise due to the effects of fibromuscular pulleys on the functional pulling directions of the rectus muscles.
Song, Hong-Yan; Qiu, Bao-Feng; Liu, Chun; Zhu, Shun-Xing; Wang, Sheng-Cun; Miao, Jin; Jing, Jing; Shao, Yi-Xiang
2014-01-01
The clone library method using PCR amplification of the 16S ribosomal RNA (rRNA) gene was used to identify pathogens from corneal scrapings of C57BL/6-corneal opacity (B6-Co) mice with bacterial keratitis. All 10 samples from the eyes with bacterial keratitis showed positive PCR results. All 10 samples from the normal cornea showed negative PCR results. In all 10 PCR-positive samples, the predominant and second most predominant species accounted for 20.9 to 40.6% and 14.7 to 26.1%, respectively, of each clone library. The predominant species were Staphylococcus lentus, Pseudomonas aeruginosa, and Staphylococcus epidermidis. The microbiota analysis detected a diverse group of microbiota in the eyes of B6-Co mice with bacterial keratitis and showed that the causative pathogens could be determined based on percentages of bacterial species in the clone libraries. The bacterial species detected in this study were mostly in accordance with results of studies on clinical bacterial keratitis in human eyes. Based on the results of our previous studies and this study, the B6-Co mouse should be considered a favorable model for studying bacterial keratitis. PMID:25312507
Novel low-kVp beamlet system for choroidal melanoma
Esquivel, Carlos; Fuller, Clifton D; Waggener, Robert G; Wong, Adrian; Meltz, Martin; Blough, Melissa; Eng, Tony Y; Thomas, Charles R
2006-01-01
Background Treatment of choroidal melanoma with radiation often involves placement of customized brachytherapy eye-plaques. However, the dosimetric properties inherent in source-based radiotherapy preclude facile dose optimization to critical ocular structures. Consequently, we have constructed a novel system for utilizing small beam low-energy radiation delivery, the Beamlet Low-kVp X-ray, or "BLOKX" system. This technique relies on an isocentric rotational approach to deliver dose to target volumes within the eye, while potentially sparing normal structures. Methods Monte Carlo N-Particle (MCNP) transport code version 5.0(14) was used to simulate photon interaction with normal and tumor tissues within modeled right eye phantoms. Five modeled dome-shaped tumors with a diameter and apical height of 8 mm and 6 mm, respectively, were simulated distinct positions with respect to the macula iteratively. A single fixed 9 × 9 mm2 beamlet, and a comparison COMS protocol plaque containing eight I-125 seeds (apparent activity of 8 mCi) placed on the scleral surface of the eye adjacent to the tumor, were utilized to determine dosimetric parameters at tumor and adjacent tissues. After MCNP simulation, comparison of dose distribution at each of the 5 tumor positions for each modality (BLOKX vs. eye-plaque) was performed. Results Tumor-base doses ranged from 87.1–102.8 Gy for the BLOKX procedure, and from 335.3–338.6 Gy for the eye-plaque procedure. A reduction of dose of at least 69% to tumor base was noted when using the BLOKX. The BLOKX technique showed a significant reduction of dose, 89.8%, to the macula compared to the episcleral plaque. A minimum 71.0 % decrease in dose to the optic nerve occurred when the BLOKX was used. Conclusion The BLOKX technique allows more favorable dose distribution in comparison to standard COMS brachytherapy, as simulated using a Monte Carlo iterative mathematical modeling. Future series to determine clinical utility of such an approach are warranted. PMID:16965624
Biometric study of eyelid shape and dimensions of different races with references to beauty.
Rhee, Seung Chul; Woo, Kyoung-Sik; Kwon, Bongsik
2012-10-01
There are few studies that evaluate the differences in the perception of beauty and attractiveness of different races or ethnicities. The purpose of this study was to determine whether there are any actual differences in the configuration of beautiful eyes among different races. Using seven composite faces of different races or ethnicities, photogrammetric measurements were performed to determine the relative differences in the average and attractive configuration of the eyes. Fourteen distance measurements and five angular measurements were performed for analyzing the morphological differences in the configuration of attractive and average faces. The results of our study found that attractive Korean faces have relatively wide-set eyes and that the medial and lateral eye fissure height is greater than that in average Korean faces. Attractive Korean faces have larger but not ptotic eyes than those in average Korean faces and they have a narrow double fold line; however, attractive Asian faces have a slightly higher double fold line. Attractive Korean or Asian faces do not have an epicanthus and there is a lot of exposure of white in the medial and lateral area of the eyes. Attractive Caucasian and African faces have an acute or keen shape to the eyes like the jaguar's eye. Attractive Asian faces have a less steep slant of the palpebral fissure compared to that of the average Asian face, but attractive Caucasian and African faces have a steeper palpebral slant than that of average Caucasian and African faces. Attractive Caucasian and African faces have a relatively narrower palpebral fissure height and width than average Caucasian and African faces. Regardless of race, attractive faces have wide-set eyes and a lower brow position than average faces. "Beautiful eyes" can be defined as youthful, brilliant, vivid, and attractive. We found that there are some common and some different characteristics in the configuration of beautiful eyes according to racial background. This journal requires that authors assign a level of evidence to each article.
Compensating For Movement Of Eye In Laser Surgery
NASA Technical Reports Server (NTRS)
Juday, Richard D.
1991-01-01
Conceptual system for laser surgery of retina includes subsystem that tracks position of retina. Tracking signal used to control galvanometer-driven mirrors keeping laser aimed at desired spot on retina as eye moves. Alternatively or additionally, indication of position used to prevent firing of laser when eye moved too far from proper aiming position.
Barry, J C; Backes, A
1998-04-01
The alternating prism and cover test is the conventional test for the measurement of the angle of strabismus. The error induced by the prismatic effect of glasses is typically about 27-30%/10 D. Alternatively, the angle of strabismus can be measured with methods based on Purkinje reflex positions. This study examines the differences between three such options, taking into account the influence of glasses. The studied system comprised the eyes with or without glasses, a fixation object and a device for recording the eye position: in the case of the alternate prism and cover test, a prism bar was required; in the case of a Purkinje reflex based device, light sources for generation of reflexes and a camera for the documentation of the reflex positions were used. Measurements performed on model eyes and computer ray traces were used to analyze and compare the options. When a single corneal reflex is used, the misalignment of the corneal axis can be measured; the error in this measurement due to the prismatic effect of glasses was 7.6%/10 D, the smallest found in this study. The individual Hirschberg ratio can be determined by monocular measurements in three gaze directions. The angle of strabismus can be measured with Purkinje reflex based methods if the fundamental differences between these methods and the alternate prism and cover test, and if the influence of glasses and other sources of error are accounted for.
Photorefractor ocular screening system
NASA Technical Reports Server (NTRS)
Richardson, John R. (Inventor); Kerr, Joseph H. (Inventor)
1987-01-01
A method and apparatus for detecting human eye defects, particularly detection of refractive error is presented. Eye reflex is recorded on color film when the eyes are exposed to a flash of light. The photographs are compared with predetermined standards to detect eye defects. The base structure of the ocular screening system is a folding interconnect structure, comprising hinged sections. Attached to one end of the structure is a head positioning station which comprises vertical support, a head positioning bracket having one end attached to the top of the support, and two head positioning lamps to verify precise head positioning. At the opposite end of the interconnect structure is a camera station with camera, electronic flash unit, and blinking fixation lamp, for photographing the eyes of persons being evaluated.
Idiosyncratic characteristics of saccadic eye movements when viewing different visual environments.
Andrews, T J; Coppola, D M
1999-08-01
Eye position was recorded in different viewing conditions to assess whether the temporal and spatial characteristics of saccadic eye movements in different individuals are idiosyncratic. Our aim was to determine the degree to which oculomotor control is based on endogenous factors. A total of 15 naive subjects viewed five visual environments: (1) The absence of visual stimulation (i.e. a dark room); (2) a repetitive visual environment (i.e. simple textured patterns); (3) a complex natural scene; (4) a visual search task; and (5) reading text. Although differences in visual environment had significant effects on eye movements, idiosyncrasies were also apparent. For example, the mean fixation duration and size of an individual's saccadic eye movements when passively viewing a complex natural scene covaried significantly with those same parameters in the absence of visual stimulation and in a repetitive visual environment. In contrast, an individual's spatio-temporal characteristics of eye movements during active tasks such as reading text or visual search covaried together, but did not correlate with the pattern of eye movements detected when viewing a natural scene, simple patterns or in the dark. These idiosyncratic patterns of eye movements in normal viewing reveal an endogenous influence on oculomotor control. The independent covariance of eye movements during different visual tasks shows that saccadic eye movements during active tasks like reading or visual search differ from those engaged during the passive inspection of visual scenes.
Signal-dependent noise determines motor planning
NASA Astrophysics Data System (ADS)
Harris, Christopher M.; Wolpert, Daniel M.
1998-08-01
When we make saccadic eye movements or goal-directed arm movements, there is an infinite number of possible trajectories that the eye or arm could take to reach the target,. However, humans show highly stereotyped trajectories in which velocity profiles of both the eye and hand are smooth and symmetric for brief movements,. Here we present a unifying theory of eye and arm movements based on the single physiological assumption that the neural control signals are corrupted by noise whose variance increases with the size of the control signal. We propose that in the presence of such signal-dependent noise, the shape of a trajectory is selected to minimize the variance of the final eye or arm position. This minimum-variance theory accurately predicts the trajectories of both saccades and arm movements and the speed-accuracy trade-off described by Fitt's law. These profiles are robust to changes in the dynamics of the eye or arm, as found empirically,. Moreover, the relation between path curvature and hand velocity during drawing movements reproduces the empirical `two-thirds power law',. This theory provides a simple and powerful unifying perspective for both eye and arm movement control.
The Dorsal Visual System Predicts Future and Remembers Past Eye Position
Morris, Adam P.; Bremmer, Frank; Krekelberg, Bart
2016-01-01
Eye movements are essential to primate vision but introduce potentially disruptive displacements of the retinal image. To maintain stable vision, the brain is thought to rely on neurons that carry both visual signals and information about the current direction of gaze in their firing rates. We have shown previously that these neurons provide an accurate representation of eye position during fixation, but whether they are updated fast enough during saccadic eye movements to support real-time vision remains controversial. Here we show that not only do these neurons carry a fast and accurate eye-position signal, but also that they support in parallel a range of time-lagged variants, including predictive and post dictive signals. We recorded extracellular activity in four areas of the macaque dorsal visual cortex during a saccade task, including the lateral and ventral intraparietal areas (LIP, VIP), and the middle temporal (MT) and medial superior temporal (MST) areas. As reported previously, neurons showed tonic eye-position-related activity during fixation. In addition, they showed a variety of transient changes in activity around the time of saccades, including relative suppression, enhancement, and pre-saccadic bursts for one saccade direction over another. We show that a hypothetical neuron that pools this rich population activity through a weighted sum can produce an output that mimics the true spatiotemporal dynamics of the eye. Further, with different pooling weights, this downstream eye position signal (EPS) could be updated long before (<100 ms) or after (<200 ms) an eye movement. The results suggest a flexible coding scheme in which downstream computations have access to past, current, and future eye positions simultaneously, providing a basis for visual stability and delay-free visually-guided behavior. PMID:26941617
Gravity modulates Listing's plane orientation during both pursuit and saccades
NASA Technical Reports Server (NTRS)
Hess, Bernhard J M.; Angelaki, Dora E.
2003-01-01
Previous studies have shown that the spatial organization of all eye orientations during visually guided saccadic eye movements (Listing's plane) varies systematically as a function of static and dynamic head orientation in space. Here we tested if a similar organization also applies to the spatial orientation of eye positions during smooth pursuit eye movements. Specifically, we characterized the three-dimensional distribution of eye positions during horizontal and vertical pursuit (0.1 Hz, +/-15 degrees and 0.5 Hz, +/-8 degrees) at different eccentricities and elevations while rhesus monkeys were sitting upright or being statically tilted in different roll and pitch positions. We found that the spatial organization of eye positions during smooth pursuit depends on static orientation in space, similarly as during visually guided saccades and fixations. In support of recent modeling studies, these results are consistent with a role of gravity on defining the parameters of Listing's law.
Duan, Hong; de Navas, Luis F; Hu, Fuqu; Sun, Kailiang; Mavromatakis, Yannis E; Viets, Kayla; Zhou, Cyrus; Kavaler, Joshua; Johnston, Robert J; Tomlinson, Andrew; Lai, Eric C
2018-04-09
Photoreceptors in the crystalline Drosophila eye are recruited by receptor tyrosine kinase (RTK)/Ras signaling mediated by Epidermal growth factor receptor (EGFR) and the Sevenless (Sev) receptor. Analyses of an allelic deletion series of the mir-279/996 locus, along with a panel of modified genomic rescue transgenes, show that Drosophila eye patterning depends on both miRNAs. Transcriptional reporter and activity sensor transgenes reveal expression and function of miR-279/996 in non-neural cells of the developing eye. Moreover, mir-279/996 mutants exhibit substantial numbers of ectopic photoreceptors, particularly of R7, and cone cell loss. These miRNAs restrict RTK signaling in the eye, since mir-279/996 nulls are dominantly suppressed by positive components of the EGFR pathway and enhanced by heterozygosity for an EGFR repressor. miR-279/996 limit photoreceptor recruitment by targeting multiple positive RTK/Ras signaling components that promote photoreceptor/R7 specification. Strikingly, deletion of mir-279/996 sufficiently derepresses RTK/Ras signaling so as to rescue a population of R7 cells in R7-specific RTK null mutants boss and sev , which otherwise completely lack this cell fate. Altogether, we reveal a rare setting of developmental cell specification that involves substantial miRNA control. © 2018. Published by The Company of Biologists Ltd.
Effect of structured visual environments on apparent eye level.
Stoper, A E; Cohen, M M
1989-11-01
Each of 12 subjects set a binocularly viewed target to apparent eye level; the target was projected on the rear wall of an open box, the floor of which was horizontal or pitched up and down at angles of 7.5 degrees and 15 degrees. Settings of the target were systematically biased by 60% of the pitch angle when the interior of the box was illuminated, but by only 5% when the interior of the box was darkened. Within-subjects variability of the settings was less under illuminated viewing conditions than in the dark, but was independent of box pitch angle. In a second experiment, 11 subjects were tested with an illuminated pitched box, yielding biases of 53% and 49% for binocular and monocular viewing conditions, respectively. The results are discussed in terms of individual and interactive effects of optical, gravitational, and extraretinal eye-position information in determining judgements of eye level.
SU-E-T-443: Geometric Uncertainties in Eye Plaque Dosimetry for a Fully Loaded 16 Mm COMS Plaque
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morrison, H; Menon, G; Jans, H
Purpose: To determine the effect of geometric uncertainties in the seed positions in a COMS eye plaque on the central axis (CAX) dose. Methods: A Silastic insert was placed into a photopolymer 3D printed 16 mm COMS plaque, which was then positioned onto a custom-designed PMMA eye phantom. High resolution 3D images were acquired of the setup using a Siemens Inveon microPET/CT scanner. Images were acquired with the plaque unloaded and loaded with IsoAid I-125 seed shells (lack of silver core to minimize metal artifacts). Seed positions and Silastic thickness beneath each slot were measured. The measured seed coordinates weremore » used to alter the seed positions within a standard 16 mm COMS plaque in Plaque Simulator v5.7.3 software. Doses along the plaque CAX were compared for the original and modified plaque coordinates using 3.5 mCi seeds with treatment times set to deliver 70 Gy to tumour apexes of 3.5, 5, and 10 mm height. Results: The majority of seeds showed length-wise displacement, and all seeds showed displacement radially outward from the eye center. The average radial displacement was 0.15 mm larger than the expected 1.4 mm offset, approximately half of which was due to increased Silastic thickness beneath each slot. The CAX doses for the modified seed positions were consistently lower for all tumour heights due to geometric displacement of the seeds; dose differences were found to increase to a maximum of 2.6% at a depth of ∼10 mm, after which they decreased due to the inverse square dose fall-off minimizing this effect. Conclusion: This work presents initial results of a broader dosimetric uncertainty evaluation for fully loaded COMS eye plaques and demonstrates the effects of seed positioning uncertainties. The small shifts in seed depths had noticeable effects on the CAX doses indicating the importance of careful Silastic loading. Funding provided by Alberta Cancer Foundation Grant #26655, Vanier Canada Graduate Scholarship, and Alberta Innovates Health Sciences Graduate Studentship.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perisinakis, Kostas; Seimenis, Ioannis; Tzedakis, Antonis
Purpose: To determine patient-specific absorbed peak doses to skin, eye lens, brain parenchyma, and cranial red bone marrow (RBM) of adult individuals subjected to low-dose brain perfusion CT studies on a 256-slice CT scanner, and investigate the effect of patient head size/shape, head position during the examination and bowtie filter used on peak tissue doses. Methods: The peak doses to eye lens, skin, brain, and RBM were measured in 106 individual-specific adult head phantoms subjected to the standard low-dose brain perfusion CT on a 256-slice CT scanner using a novel Monte Carlo simulation software dedicated for patient CT dosimetry. Peakmore » tissue doses were compared to corresponding thresholds for induction of cataract, erythema, cerebrovascular disease, and depression of hematopoiesis, respectively. The effects of patient head size/shape, head position during acquisition and bowtie filter used on resulting peak patient tissue doses were investigated. The effect of eye-lens position in the scanned head region was also investigated. The effect of miscentering and use of narrow bowtie filter on image quality was assessed. Results: The mean peak doses to eye lens, skin, brain, and RBM were found to be 124, 120, 95, and 163 mGy, respectively. The effect of patient head size and shape on peak tissue doses was found to be minimal since maximum differences were less than 7%. Patient head miscentering and bowtie filter selection were found to have a considerable effect on peak tissue doses. The peak eye-lens dose saving achieved by elevating head by 4 cm with respect to isocenter and using a narrow wedge filter was found to approach 50%. When the eye lies outside of the primarily irradiated head region, the dose to eye lens was found to drop to less than 20% of the corresponding dose measured when the eye lens was located in the middle of the x-ray beam. Positioning head phantom off-isocenter by 4 cm and employing a narrow wedge filter results in a moderate reduction of signal-to-noise ratio mainly to the peripheral region of the phantom. Conclusions: Despite typical peak doses to skin, eye lens, brain, and RBM from the standard low-dose brain perfusion 256-slice CT protocol are well below the corresponding thresholds for the induction of erythema, cataract, cerebrovascular disease, and depression of hematopoiesis, respectively, every effort should be made toward optimization of the procedure and minimization of dose received by these tissues. The current study provides evidence that the use of the narrower bowtie filter available may considerably reduce peak absorbed dose to all above radiosensitive tissues with minimal deterioration in image quality. Considerable reduction in peak eye-lens dose may also be achieved by positioning patient head center a few centimeters above isocenter during the exposure.« less
Kim, Ho Soong; Park, Ki Ho; Jeoung, Jin Wook
2013-11-01
To evaluate the amount of intraocular pressure (IOP) change in the eye against the pillow in the lateral decubitus position (LDP). Thirty eyes from 15 healthy volunteers (12 men and three women) aged 29 ± 3 (range 25-37) years participated in this study. Using the rebound tonometer (Icare PRO, Icare Finland Oy, Helsinki, Finland), the IOP of both eyes was checked in sitting, supine, right and left LDPs. In the LDP, the additional IOP measurements were taken with the lower eyeball against the latex pillow. Baseline IOP in the sitting position was 12.7 ± 1.9 mmHg in the right eye and 12.8 ± 2.2 mmHg in the left eye. Ten minutes after shifting from the sitting to the supine position, IOP increased significantly (right eye: +1.4 ± 1.4 mmHg, p = 0.006; left eye: +1.8 ± 1.5 mmHg, p = 0.001). Changing from the supine to the right and left LDP increased significantly the IOP of dependent eye (right eye: +2.3 ± 1.8 mmHg, p = 0.001; left eye: +1.5 ± 1.8 mmHg, p = 0.011). When the dependent eye was compressed against the pillow in the LDP, the IOP of the dependent eyes increased significantly after 10 min (right eye in the right LDP: +4.1 ± 4.9 mmHg, p = 0.011; left eye in the left LDP: +3.4 ± 3.7 mmHg, p = 0.006). The IOP was significantly elevated when the eyeball was against the pillow in the LDP. © 2013 Acta Ophthalmologica Scandinavica Foundation. Published by Blackwell Publishing Ltd.
Kim, Ko Eun; Jeoung, Jin Wook; Park, Ki Ho; Kim, Dong Myung; Kim, Seok Hwan
2015-03-01
To investigate the rate and associated factors of false-positive diagnostic classification of ganglion cell analysis (GCA) and retinal nerve fiber layer (RNFL) maps, and characteristic false-positive patterns on optical coherence tomography (OCT) deviation maps. Prospective, cross-sectional study. A total of 104 healthy eyes of 104 normal participants. All participants underwent peripapillary and macular spectral-domain (Cirrus-HD, Carl Zeiss Meditec Inc, Dublin, CA) OCT scans. False-positive diagnostic classification was defined as yellow or red color-coded areas for GCA and RNFL maps. Univariate and multivariate logistic regression analyses were used to determine associated factors. Eyes with abnormal OCT deviation maps were categorized on the basis of the shape and location of abnormal color-coded area. Differences in clinical characteristics among the subgroups were compared. (1) The rate and associated factors of false-positive OCT maps; (2) patterns of false-positive, color-coded areas on the GCA deviation map and associated clinical characteristics. Of the 104 healthy eyes, 42 (40.4%) and 32 (30.8%) showed abnormal diagnostic classifications on any of the GCA and RNFL maps, respectively. Multivariate analysis revealed that false-positive GCA diagnostic classification was associated with longer axial length and larger fovea-disc angle, whereas longer axial length and smaller disc area were associated with abnormal RNFL maps. Eyes with abnormal GCA deviation map were categorized as group A (donut-shaped round area around the inner annulus), group B (island-like isolated area), and group C (diffuse, circular area with an irregular inner margin in either). The axial length showed a significant increasing trend from group A to C (P=0.001), and likewise, the refractive error was more myopic in group C than in groups A (P=0.015) and B (P=0.014). Group C had thinner average ganglion cell-inner plexiform layer thickness compared with other groups (group A=B>C, P=0.004). Abnormal OCT diagnostic classification should be interpreted with caution, especially in eyes with long axial lengths, large fovea-disc angles, and small optic discs. Our findings suggest that the characteristic patterns of OCT deviation map can provide useful clues to distinguish glaucomatous changes from false-positive findings. Copyright © 2015 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Lobo, Ann-Marie; Gao, Yan; Rusie, Laura; Houlberg, Magda; Mehta, Supriya D
2018-03-01
In 2015, the Centers for Disease Control and Prevention (CDC) and the American Academy of Ophthalmology (AAO) released clinical advisories on rising cases of ocular syphilis. We examined the association between eye disease and syphilis infection among primary care and sexually transmitted infection (STI) clinic patients attending an urban lesbian, gay, bisexual, transgender (LGBT) health center. We conducted a retrospective medical record review of all patients who underwent syphilis testing at Howard Brown Health between 1 January 2010 and 31 December 2015. Confirmed eye diagnosis was based on International Classification of Diseases, Ninth Revision (ICD-9) diagnosis codes for conjunctivitis, uveitis, keratitis, retinitis, and red eye. Demographic information, syphilis treatment, HIV status, and high-risk behaviors were abstracted. Syphilis diagnosis was defined by available laboratory data (enzyme immunoassay [EIA], rapid plasma reagin [RPR] titer, fluorescent treponemal antibody absorption [FTA-Abs], Treponema pallidum Ab). Multivariable logistic regression with robust variance was used to identify independent associations. During the study period, 71,299 syphilis tests were performed on 30,422 patients. There were 2288 (3.2%) positive syphilis tests. Seventy-seven patients had a confirmed eye diagnosis (0.25%). Patients with eye disease had higher probability of at least one positive syphilis test (33%) compared to those without eye disease (8%) ( p < 0.01). Of patients with eye disease, 77% were men who had sex with men (MSM) and 65% were HIV-positive. Patients with eye disease had 5.97 (95% CI: 3.70, 9.63) higher odds of having syphilis compared to patients without eye disease. When adjusted for age, race, gender/sexual orientation, insurance status, and HIV status, this association between positive syphilis test and eye disease decreased but was still significant (OR 2.00, 95% CI 1.17, 3.41). Patients who present with an eye diagnosis to STI/primary care clinic have a higher probability of positive syphilis tests even after adjusting for other risk factors for syphilis. High-risk patients with eye symptoms should have routine STI testing and in keeping with CDC and AAO recommendations, full ophthalmologic examination.
Suzuki, David A; Yamada, Tetsuto; Yee, Robert D
2003-04-01
Neuronal responses that were observed during smooth-pursuit eye movements were recorded from cells in rostral portions of the nucleus reticularis tegmenti pontis (rNRTP). The responses were categorized as smooth-pursuit eye velocity (78%) or eye acceleration (22%). A separate population of rNRTP cells encoded static eye position. The sensitivity to pursuit eye velocity averaged 0.81 spikes/s per degrees /s, whereas the average sensitivity to pursuit eye acceleration was 0.20 spikes/s per degrees /s(2). Of the eye-velocity cells with horizontal preferences for pursuit responses, 56% were optimally responsive to contraversive smooth-pursuit eye movements and 44% preferred ipsiversive pursuit. For cells with vertical pursuit preferences, 61% preferred upward pursuit and 39% preferred downward pursuit. The direction selectivity was broad with 50% of the maximal response amplitude observed for directions of smooth pursuit up to +/-85 degrees away from the optimal direction. The activities of some rNRTP cells were linearly related to eye position with an average sensitivity of 2.1 spikes/s per deg. In some cells, the magnitude of the response during smooth-pursuit eye movements was affected by the position of the eyes even though these cells did not encode eye position. On average, pursuit centered to one side of screen center elicited a response that was 73% of the response amplitude obtained with tracking centered at screen center. For pursuit centered on the opposite side, the average response was 127% of the response obtained at screen center. The results provide a neuronal rationale for the slow, pursuit-like eye movements evoked with rNRTP microstimulation and for the deficits in smooth-pursuit eye movements observed with ibotenic acid injection into rNRTP. More globally, the results support the notion of a frontal and supplementary eye field-rNRTP-cerebellum pathway involved with controlling smooth-pursuit eye movements.
Eye lens dose in interventional cardiology.
Principi, S; Delgado Soler, C; Ginjaume, M; Beltran Vilagrasa, M; Rovira Escutia, J J; Duch, M A
2015-07-01
The ICRP has recently recommended reducing the occupational exposure dose limit for the lens of the eye to 20 mSv y(-1), averaged over a period of 5 y, with no year exceeding 50 mSv, instead of the current 150 mSv y(-1). This reduction will have important implications for interventional cardiology and radiology (IC/IR) personnel. In this work, lens dose received by a staff working in IC is studied in order to determine whether eye lens dose monitoring or/and additional radiological protection measures are required. Eye lens dose exposure was monitored in 10 physicians and 6 nurses. The major IC procedures performed were coronary angiography and percutaneous transluminal coronary angioplasty. The personnel were provided with two thermoluminescent dosemeters (TLDs): one calibrated in terms of Hp(3) located close to the left ear of the operator and a whole-body dosemeter calibrated in terms of Hp(10) and Hp(0.07) positioned on the lead apron. The estimated annual eye lens dose for physicians ranged between 8 and 60 mSv, for a workload of 200 procedures y(-1). Lower doses were collected for nurses, with estimated annual Hp(3) between 2 and 4 mSv y(-1). It was observed that for nurses the Hp(0.07) measurement on the lead apron is a good estimate of eye lens dose. This is not the case for physicians, where the influence of both the position and use of protective devices such as the ceiling shield is very important and produces large differences among doses both at the eyes and on the thorax. For physicians, a good correlation between Hp(3) and dose area product is shown. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Niechwiej-Szwedo, E; González, E; Bega, S; Verrier, M C; Wong, A M; Steinbach, M J
2006-07-01
A proprioceptive hypothesis for the control of eye movements has been recently proposed based on neuroanatomical tracing studies. It has been suggested that the non-twitch motoneurons could be involved in modulating the gain of sensory feedback from the eye muscles analogous to the gamma (gamma) motoneurons which control the gain of proprioceptive feedback in skeletal muscles. We conducted behavioral and psychophysical experiments to test the above hypothesis using the Jendrassik Maneuver (JM) to alter the activity of gamma motoneurons. It was hypothesized that the JM would alter the proprioceptive feedback from the eye muscles which would result in misregistration of eye position and mislocalization of targets. In the first experiment, vergence eye movements and pointing responses were examined. Data showed that the JM affected the localization responses but not the actual eye position. Perceptual judgments were tested in the second experiment, and the results showed that targets were perceived as farther when the afferent feedback was altered by the JM. Overall, the results from the two experiments showed that eye position was perceived as more divergent with the JM, but the actual eye movements were not affected. We tested this further in Experiment 3 by examining the effect of JM on the amplitude and velocity of saccadic eye movements. As expected, there were no significant differences in saccadic parameters between the control and experimental conditions. Overall, the present study provides novel insight into the mechanism which may be involved in the use of sensory feedback from the eye muscles. Data from the first two experiments support the hypothesis that the JM alters the registered eye position, as evidenced by the localization errors. We propose that the altered eye position signal is due to the effect of the JM which changes the gain of the sensory feedback from the eye muscles, possibly via the activity of non-twitch motoneurons.
Reliability of Corneal Dynamic Scheimpflug Analyser Measurements in Virgin and Post-PRK Eyes
Chen, Xiangjun; Stojanovic, Aleksandar; Hua, Yanjun; Eidet, Jon Roger; Hu, Di; Wang, Jingting; Utheim, Tor Paaske
2014-01-01
Purpose To determine the measurement reliability of CorVis ST, a dynamic Scheimpflug analyser, in virgin and post-photorefractive keratectomy (PRK) eyes and compare the results between these two groups. Methods Forty virgin eyes and 42 post-PRK eyes underwent CorVis ST measurements performed by two technicians. Repeatability was evaluated by comparing three consecutive measurements by technician A. Reproducibility was determined by comparing the first measurement by technician A with one performed by technician B. Intraobserver and interobserver intraclass correlation coefficients (ICCs) were calculated. Univariate analysis of covariance (ANCOVA) was used to compare measured parameters between virgin and post-PRK eyes. Results The intraocular pressure (IOP), central corneal thickness (CCT) and 1st applanation time demonstrated good intraobserver repeatability and interobserver reproducibility (ICC≧0.90) in virgin and post-PRK eyes. The deformation amplitude showed a good or close to good repeatability and reproducibility in both groups (ICC≧0.88). The CCT correlated positively with 1st applanation time (r = 0.437 and 0.483, respectively, p<0.05) and negatively with deformation amplitude (r = −0.384 and −0.375, respectively, p<0.05) in both groups. Compared to post-PRK eyes, virgin eyes showed longer 1st applanation time (7.29±0.21 vs. 6.96±0.17 ms, p<0.05) and lower deformation amplitude (1.06±0.07 vs. 1.17±0.08 mm, p<0.05). Conclusions CorVis ST demonstrated reliable measurements for CCT, IOP, and 1st applanation time, as well as relatively reliable measurement for deformation amplitude in both virgin and post-PRK eyes. There were differences in 1st applanation time and deformation amplitude between virgin and post-PRK eyes, which may reflect corneal biomechanical changes occurring after the surgery in the latter. PMID:25302580
Relative axial myopia in Egr-1 (ZENK) knockout mice.
Schippert, Ruth; Burkhardt, Eva; Feldkaemper, Marita; Schaeffel, Frank
2007-01-01
Experiments in chickens have implicated the transcription factor ZENK (also known as Egr-1, NGFI-A, zif268, tis8, cef5, and Krox24) in the feedback mechanisms for visual control of axial eye growth and myopia development. ZENK is upregulated in retinal glucagon amacrine cells when axial eye growth is inhibited by positive spectacle lens wear and is downregulated when it is enhanced by negative spectacle lens wear, suggesting that ZENK may be linked to an inhibitory signal for axial eye growth. This study was undertaken to determine whether a Egr-1(-/-) knockout mouse mutant, lacking ZENK completely, has longer eyes and more myopic refraction, than do Egr-1(+/)(-) heterozygous and Egr-1(+/+) wild-type mice with near-identical genetic backgrounds. Eye growth and refractive development were tracked from day P28 to P98. Corneal radius of curvature was measured with infrared photokeratometry, refractive state with infrared photoretinoscopy, and ocular dimensions with low-coherence interferometry. As a functional vision test, grating acuity was determined in an automated optomotor task. The abundance of ZENK protein in the retina was quantified by immunohistochemistry. Egr-1 knockout mice had longer eyes and a relative myopic shift in refraction, with additional minor effects on anterior chamber depth and corneal radius of curvature. Paraxial schematic eye modeling suggested changes in the optics of the crystalline lens as well. With increasing age, the differences between mutant and wild-type mice declined, although the differences in refraction persisted over the observation period. Grating acuity was not affected by the lack of the Egr-1 protein during development. Although it has been shown that different mouse strains may have differently large eyes, the present study shows that a specific gene knockout can produce relative myopia, compared with the wild-type with near-identical genetic background. Further experiments are needed to determine whether the observed effects of Egr-1 deletion are due to changes in function within the retina or other ocular tissues or to changes of function in other systems that may affect ocular growth from outside the eye.
Individual differences in personality predict how people look at faces.
Perlman, Susan B; Morris, James P; Vander Wyk, Brent C; Green, Steven R; Doyle, Jaime L; Pelphrey, Kevin A
2009-06-22
Determining the ways in which personality traits interact with contextual determinants to shape social behavior remains an important area of empirical investigation. The specific personality trait of neuroticism has been related to characteristic negative emotionality and associated with heightened attention to negative, emotionally arousing environmental signals. However, the mechanisms by which this personality trait may shape social behavior remain largely unspecified. We employed eye tracking to investigate the relationship between characteristics of visual scanpaths in response to emotional facial expressions and individual differences in personality. We discovered that the amount of time spent looking at the eyes of fearful faces was positively related to neuroticism. This finding is discussed in relation to previous behavioral research relating personality to selective attention for trait-congruent emotional information, neuroimaging studies relating differences in personality to amygdala reactivity to socially relevant stimuli, and genetic studies suggesting linkages between the serotonin transporter gene and neuroticism. We conclude that personality may be related to interpersonal interaction by shaping aspects of social cognition as basic as eye contact. In this way, eye gaze represents a possible behavioral link in a complex relationship between genes, brain function, and personality.
NASA Astrophysics Data System (ADS)
Chen, Yanjie; Zhang, Quanqi; Qi, Jie; Sun, Yeying; Zhong, Qiwang; Wang, Xubo; Wang, Zhigang; Li, Shuo; Li, Chunmei
2009-02-01
Flatfish or flounder moves one eye to change body proportion into vertebral asymmetry during metamorphosis, during which some become sinistral while others dextral. However, the mechanism behinds the eye-position has not been well understood. In this research, hybrids between Japanese flounder(♀) and stone flounder (♂) show mixed eye-location in both dextral type and sinistral type, and thus become good samples for studying the eye-migration. mRNAs from pro-metamorphosis sinistral and dextral hybrids larvae were screened with classical differential display RT-PCR (DD-RT-PCR) and representational difference analysis of cDNA (cDNA-RDA); 30 and 47 putative fragments were isolated, respectively. The cDNA fragments of creatine kinase and trypsinogen 2 precursor genes isolated by cDNA-RDA exhibited eye-position expression patterns during metamorphosis. However, none of the fragments was proved to be related to flatfishes’ eye-position specifically. Therefore, further studies and more sensitive gene isolated methods are needed to solve the problems.
Double silicone tube intubation for the management of partial lacrimal system obstruction.
Demirci, Hakan; Elner, Victor M
2008-02-01
To evaluate the effectiveness of double silicone intubation for the management of partial lacrimal drainage system obstruction in adults. Observational retrospective case series. Twenty-four eyes of 18 consecutive adult patients with partial lacrimal system obstruction managed at the University of Michigan. Retrospective review of symptoms and signs, duration of silicone intubation, and complications. Resolution of tearing. Preoperative tearing, negative Jones I testing, positive Jones II testing, and resistance to positive-pressure irrigation were present in all eyes (100%). The first silicone tube was removed after a mean of 11+/-7 months, and the second tube after 16+/-6 months. Postoperatively, at a mean of 21+/-9 months after removal of both tubes, tearing remained resolved in 19 eyes (79%) and remained improved in 2 eyes (8%). In eyes with resolved tearing, Jones I testing became positive, and there was no resistance to positive-pressure irrigation. Persistent tearing in 3 eyes (13%) required treatment with external dacryocystorhinostomy. The only complication was peripunctal pyogenic granulomas in 2 eyes. Double silicone intubation is an effective minimally invasive technique for treatment of partial lacrimal system obstruction in adults.
Kim, Young Kook; Yoo, Byeong Wook; Jeoung, Jin Wook; Kim, Hee Chan; Kim, Hae Jin; Park, Ki Ho
2016-11-01
To evaluate the glaucoma-diagnostic ability of the ganglion cell-inner plexiform layer (GCIPL) thickness difference across the temporal raphe in highly myopic eyes. We consecutively enrolled a total of 195 highly myopic eyes (axial length [AL] >26.5 mm) of 195 subjects: 93 glaucoma patients along with and 102 nonglaucomatous subjects. Cirrus high-definition optical coherence tomography (OCT) was employed to scan all of the subjects' macular and optic discs. Using a MATLAB-based customized program (the GCIPL hemifield test), a positive test result was automatically declared if the following two conditions were met: (1) the horizontal line is detected for longer than one-half of the distance from the temporal inner elliptical annulus to the outer elliptical annulus, and (2) the average GCIPL thickness difference within 10 pixels of the reference line, both above and below, is 5 μm or more. The glaucoma-diagnostic ability was computed using the area under the receiver operating characteristic curve (AUC). Among the glaucomatous eyes, GCIPL hemifield test positivity was shown in 92.5% (86 of 93), significantly higher than that for the nonglaucomatous eyes (4.90%, 5 of 102; P <0.001). The value of AUC for the GCIPL hemifield test was excellent (0.938; sensitivity 92.50%, specificity 95.10%) and was the best compared with those for any of OCT parameters. In highly myopic eyes, determination of the presence or absence of GCIPL thickness difference across the temporal raphe via OCT macula scan can be a useful means of distinguishing the glaucomatous damage.
Predictive performance of the Vitrigel-eye irritancy test method using 118 chemicals.
Yamaguchi, Hiroyuki; Kojima, Hajime; Takezawa, Toshiaki
2016-08-01
We recently developed a novel Vitrigel-eye irritancy test (EIT) method. The Vitrigel-EIT method is composed of two parts, i.e., the construction of a human corneal epithelium (HCE) model in a collagen vitrigel membrane chamber and the prediction of eye irritancy by analyzing the time-dependent profile of transepithelial electrical resistance values for 3 min after exposing a chemical to the HCE model. In this study, we estimated the predictive performance of Vitrigel-EIT method by testing a total of 118 chemicals. The category determined by the Vitrigel-EIT method in comparison to the globally harmonized system classification revealed that the sensitivity, specificity and accuracy were 90.1%, 65.9% and 80.5%, respectively. Here, five of seven false-negative chemicals were acidic chemicals inducing the irregular rising of transepithelial electrical resistance values. In case of eliminating the test chemical solutions showing pH 5 or lower, the sensitivity, specificity and accuracy were improved to 96.8%, 67.4% and 84.4%, respectively. Meanwhile, nine of 16 false-positive chemicals were classified irritant by the US Environmental Protection Agency. In addition, the disappearance of ZO-1, a tight junction-associated protein and MUC1, a cell membrane-spanning mucin was immunohistologically confirmed in the HCE models after exposing not only eye irritant chemicals but also false-positive chemicals, suggesting that such false-positive chemicals have an eye irritant potential. These data demonstrated that the Vitrigel-EIT method could provide excellent predictive performance to judge the widespread eye irritancy, including very mild irritant chemicals. We hope that the Vitrigel-EIT method contributes to the development of safe commodity chemicals. Copyright © 2015 The Authors. Journal of Applied Toxicology published by John Wiley & Sons Ltd. Copyright © 2015 The Authors. Journal of Applied Toxicology published by John Wiley & Sons Ltd.
Sambursky, Robert
2016-01-01
The presence of clinically significant inflammation has been confirmed in the tears of 40%-65% of patients with symptoms of dry eye. Ocular surface inflammation may lead to tear film instability, epithelial cell irregularities, and permeability, resulting in chronic symptomatic pain and fluctuating vision as well as negative surgical outcomes. A retrospective single center medical chart review of 100 patients was conducted. All patients were tested with the InflammaDry test to determine if patients exhibited elevated levels of matrix metalloproteinase 9 (MMP-9). InflammaDry-positive patients were started on a combination of cyclosporine 0.05% twice daily, 2,000-4,000 mg oral omega-3 fatty acids, and frequent artificial tear replacement. InflammaDry-negative patients were started on 2,000-4,000 mg of oral omega-3 fatty acids and frequent artificial tear replacement. Each patient was retested at ~90 days. A symptom questionnaire was performed at the initial visit and at 90 days. 60% of the patients with dry eye symptoms tested positive for elevated MMP-9 at the initial visit. 78% of all patients returned for follow-up at ~90 days including 80% (48/60) of the previously InflammaDry-positive patients and 75% (30/40) of the previously InflammaDry-negative patients. A follow-up symptom questionnaire reported at least 75% symptomatic improvement in 65% (31/48) of the originally InflammaDry-positive patients and in 70% (21/30) of the initially InflammaDry-negative patients. Symptomatic improvement of at least 50% was reported in 85% (41/48) of previously InflammaDry-positive patients and 86% (26/30) of previously InflammaDry-negative patients. Following treatment, 54% (26/48) of previously InflammaDry-positive patients converted to a negative InflammaDry result. Identifying which symptomatic dry eye patients have underlying inflammation may predict patient responses to treatment and influence clinical management strategies.
Sambursky, Robert
2016-01-01
Background The presence of clinically significant inflammation has been confirmed in the tears of 40%–65% of patients with symptoms of dry eye. Ocular surface inflammation may lead to tear film instability, epithelial cell irregularities, and permeability, resulting in chronic symptomatic pain and fluctuating vision as well as negative surgical outcomes. Patients and methods A retrospective single center medical chart review of 100 patients was conducted. All patients were tested with the InflammaDry test to determine if patients exhibited elevated levels of matrix metalloproteinase 9 (MMP-9). InflammaDry-positive patients were started on a combination of cyclosporine 0.05% twice daily, 2,000–4,000 mg oral omega-3 fatty acids, and frequent artificial tear replacement. InflammaDry-negative patients were started on 2,000–4,000 mg of oral omega-3 fatty acids and frequent artificial tear replacement. Each patient was retested at ~90 days. A symptom questionnaire was performed at the initial visit and at 90 days. Results 60% of the patients with dry eye symptoms tested positive for elevated MMP-9 at the initial visit. 78% of all patients returned for follow-up at ~90 days including 80% (48/60) of the previously InflammaDry-positive patients and 75% (30/40) of the previously InflammaDry-negative patients. A follow-up symptom questionnaire reported at least 75% symptomatic improvement in 65% (31/48) of the originally InflammaDry-positive patients and in 70% (21/30) of the initially InflammaDry-negative patients. Symptomatic improvement of at least 50% was reported in 85% (41/48) of previously InflammaDry-positive patients and 86% (26/30) of previously InflammaDry-negative patients. Following treatment, 54% (26/48) of previously InflammaDry-positive patients converted to a negative InflammaDry result. Conclusion Identifying which symptomatic dry eye patients have underlying inflammation may predict patient responses to treatment and influence clinical management strategies. PMID:27920494
Anastasopoulos, D; Mandellos, D; Kostadima, V; Pettorossi, V E
2002-08-01
We studied the amplitude, latency, and probability of occurrence of fast phases (FP) in darkness to unpredictable vestibular and/or cervical yaw stimulation in normal human subjects. The rotational stimuli were smoothed trapezoidal motion transients of 14 degrees amplitude and 1.25 s duration. Eye position before stimulus application (initial eye position, IEP) was introduced as a variable by asking the subjects to fixate a spot appearing either straight ahead or at 7 degrees eccentric positions. The recordings demonstrated that the generation of FP during vestibular stimulation was facilitated when the whole-body rotation was directed opposite the eccentric IEP. Conversely, FP were attenuated if the whole-body rotation was directed toward the eccentric IEP; i.e., the FP attenuated if they were made to further eccentric positions. Cervical stimulation-induced FP were small and variable in direction when IEP was directed straight ahead before stimulus onset. Eccentric IEPs resulted in large FP, the direction of which was essentially independent of the neck-proprioceptive stimulus. They tended to move the eye toward the primary position, both when the trunk motion under the stationary head was directed toward or away from the IEP. FP dependence on IEP was evident also during head-on-trunk rotations. No consistent interaction between vestibularly and cervically induced FP was found. We conclude that extraretinal eye position signals are able to modify vestibularly evoked reflexive FP in darkness, aiming at minimizing excursions of the eyes away from the primary position. However, neck-induced FP do not relate to specific tasks of stabilization or visual search. By keeping the eyes near the primary position, FP may permit flexibility of orienting responses to incoming stimuli. This recentering bias for both vestibularly and cervically generated FP may represent a visuomotor optimizing strategy.
NASA Technical Reports Server (NTRS)
Cohen, B.; Cohen, N.; Helwig, D.; Solomon, D.; Kozlovskaya, I.; Sirota, M.; Yakushin, S.; Raphan, T.
1994-01-01
This technical paper discusses the following: (1) The VOR of two rhesus monkeys was studied before and after 14 days of spaceflight to determine effects of microgravity on the VOR. Horizontal, vertical and roll eye movements were recorded in these and six other monkeys implanted with scleral search coils. Animals were rotated about a vertical axis to determine the gain of the horizontal, vertical and roll VOR. They were rotated about axes tilted from the vertical (off-vertical axis rotation, OVAR) to determine steady state gains and effects of gravity on modulations in eye position and eye velocity. They were also tested for tilt dumping of post-rotatory nystagmus. (2) The gain of the horizontal VOR was close to unity when animals were tested 15 and 18 hours after flight. VOR gain values were similar to those registered before flight. If the gain of the horizontal VOR changes in microgravity, it must revert to normal soon after landing. (3) Steady state velocities of nystagmus induced by off-vertical axis rotation (OVAR) were unchanged by adaptation to microgravity, and the phase of the modulations was similar before and after flight. However, modulations in horizontal eye velocity had more variation after landing and were on mean about 50% larger for angles of tilt of the axis of rotation between 50 and 90?/s after flight. This difference was similar in both animals and was significant. (4) A striking finding was that tilt dumping was lost in the one animal tested for this function. This loss persisted for several days after return. This is reminiscent of the loss of response to pitch while rotating in the M-131 experiments of Skylab, and must be studied in detail in future spaceflights. (5) Thus, two major findings emerged from these studies: after spaceflight the modulation of horizontal eye velocity was larger during OVAR, and one animal lost its ability to tilt-dump its nystagmus. Both findings are consistent with the postulate that adaptation to microgravity causes alterations in the way that otolith information is processed in the central nervous system. The experiments lay the groundwork for studying the vertical and roll VOR before and after future space flights, as well as for studying modulations in vertical and roll eye position during OVAR and tilt dumping.
Determining the imaging plane of a retinal capillary layer in adaptive optical imaging
NASA Astrophysics Data System (ADS)
Yang, Le-Bao; Hu, Li-Fa; Li, Da-Yu; Cao, Zhao-Liang; Mu, Quan-Quan; Ma, Ji; Xuan, Li
2016-09-01
Even in the early stage, endocrine metabolism disease may lead to micro aneurysms in retinal capillaries whose diameters are less than 10 μm. However, the fundus cameras used in clinic diagnosis can only obtain images of vessels larger than 20 μm in diameter. The human retina is a thin and multiple layer tissue, and the layer of capillaries less than 10 μm in diameter only exists in the inner nuclear layer. The layer thickness of capillaries less than 10 μm in diameter is about 40 μm and the distance range to rod&cone cell surface is tens of micrometers, which varies from person to person. Therefore, determining reasonable capillary layer (CL) position in different human eyes is very difficult. In this paper, we propose a method to determine the position of retinal CL based on the rod&cone cell layer. The public positions of CL are recognized with 15 subjects from 40 to 59 years old, and the imaging planes of CL are calculated by the effective focal length of the human eye. High resolution retinal capillary imaging results obtained from 17 subjects with a liquid crystal adaptive optics system (LCAOS) validate our method. All of the subjects’ CLs have public positions from 127 μm to 147 μm from the rod&cone cell layer, which is influenced by the depth of focus. Project supported by the National Natural Science Foundation of China (Grant Nos. 11174274, 11174279, 61205021, 11204299, 61475152, and 61405194).
Barmack, N H; Errico, P; Ferraresi, A; Pettorossi, V E
1989-01-01
1. Eye movements in unanaesthetized rabbits were studied during horizontal neck-proprioceptive stimulation (movement of the body with respect to the fixed head), when this stimulation was given alone and when it was given simultaneously with vestibular stimulation (rotation of the head-body). The effect of neck-proprioceptive stimulation on modifying the anticompensatory fast-phase eye movements (AFPs) evoked by vestibular stimulation was studied with a 'conditioning-test' protocol; the 'conditioning' stimulus was a neck-proprioceptive signal evoked by a step-like change in body position with respect to the head and the 'test' stimulus was a vestibular signal evoked by a step rotation of the head-body. 2. The influence of eye position and direction of slow eye movements on the occurrence of compensatory fast-phase eye movements (CFPs) evoked by neck-proprioceptive stimulation was also examined. 3. The anticompensatory fast phase (AFP) evoked by vestibular stimulation was attenuated by a preceding neck-proprioceptive stimulus which when delivered alone evoked compensatory slow-phase eye movements (CSP) in the same direction as the CSP evoked by vestibular stimulation. Conversely, the vestibularly evoked AFP was potentiated by a neck-proprioceptive stimulus which evoked CSPs opposite to that of vestibularly evoked CSPs. 4. Eccentric initial eye positions increased the probability of occurrence of midline-directed compensatory fast-phase eye movements (CFPs) evoked by appropriate neck-proprioceptive stimulation. 5. The gain of the horizontal cervico-ocular reflex (GHCOR) was measured from the combined changes in eye position resulting from AFPs and CSPs. GHCOR was potentiated during simultaneous vestibular stimulation. This enhancement of GHCOR occurred at neck-proprioceptive stimulus frequencies which, in the absence of conjoint vestibular stimulation, do not evoke CSPs. PMID:2795479
Effect of posture on the diurnal variation in clinically significant diabetic macular edema.
Polito, Antonio; Polini, Giovanni; Chiodini, Raffaella Gortana; Isola, Miriam; Soldano, Franca; Bandello, Francesco
2007-07-01
To investigate the role of posture and other systemic factors in the diurnal variation of clinically significant diabetic macular edema (CSDME). Ten eyes of 10 diabetic subjects with CSDME underwent four OCT foveal thickness measurements with StratusOCT at 9 AM and 12, 3, and 6 PM consecutively on two different days, with the subject in an upright position on one and in a recumbent position on the other. For the "recumbent-position" measurements, the patients were admitted the night before and remained in bed during the entire day of testing. Clinical laboratory results at baseline included HbA1c, urinary albumin, and serum creatinine. Refraction and Early Treatment Diabetic Retinopathy Study (ETDRS) visual acuity were also measured before each OCT measurement was taken. Variations in blood pressure, body temperature, plasma glucose, renin, aldosterone, and cortisol levels were measured and then correlated with macular thickness. Foveal thickening decreased in all cases over the course of the day. The decrease, however, was significantly greater for the upright-position measurements (relative mean +/- SD decrease of 20.6% +/- 6.5% in the upright position and 6.2% +/- 4.6% in the recumbent position). Visual acuity improved by at least 1 ETDRS line in three eyes in the upright position as opposed to only one eye in the recumbent position. There seemed to be no association between any of the systemic factors studied and foveal thickening, with the exception of cortisol. The results support the hypothesis that posture and hydrostatic pressure play a major role in determining time-related shifts in CSDME and suggest that the forces of Starling's law can in part, account for CSDME formation.
Improvement of horizontal macular contraction after surgical removal of epiretinal membranes.
Yang, H K; Kim, S J; Jung, Y S; Kim, K G; Kim, J H; Yu, H G
2011-06-01
To determine whether horizontal macular contraction caused by epiretinal membranes (ERMs) improves after surgical removal. In this prospective, single-center, observational study, 63 consecutive patients with unilateral idiopathic ERM in one eye and no retinal disease in the fellow eye underwent pars plana vitrectomy. Fundus photography and optical coherence tomography (OCT) were performed preoperatively and at 3 months postoperatively. The area enclosed by superior and inferior major vessels from the optic disc to the fovea (area under major vessel (AUV)) and the macroscopic diverging angle (MDA) between superior and inferior major vessels were calculated using digital image analysis of fundus photographs and compared pre- and postoperatively. AUV was significantly smaller in the eyes with ERM compared with the normal fellow eyes (P<0.001). Significant postoperative change in AUV and MDA was demonstrated after ERM removal (P<0.001). However, postoperative AUV of grade 2 and 3 ERM eyes was still significantly smaller than that of normal fellow eyes. Macular thickness differences measured with stratus OCT were positively correlated with AUV differences. Retinal topographic changes caused by ERM improved in part after ERM removal. The improvement of topographic changes were correlated with tomographic changes detected with OCT.
Octopus arm choice is strongly influenced by eye use.
Byrne, Ruth A; Kuba, Michael J; Meisel, Daniela V; Griebel, Ulrike; Mather, Jennifer A
2006-09-25
This study aims to investigate the octopus' eye and arm coordination and raises the question if visual guidance determines choice of arm use. Octopuses possess eight seemingly identical arms but have recently been reported to show a preference as to which arm they use to initiate contact with objects. These animals also exhibit lateralized eye use, therefore, a connection between eye and arm preference seems possible. Seven Octopus vulgaris were observed during approach, contact initiation and exploration of plastic objects that were positioned on three different levels in the water column. The subjects most commonly used an arm to initiate contact with an object that was in a direct line between the eye used to look at the object, and the object itself. This indicates that choice of arm use is spatially rather opportunistic when depending on visual guidance. Additionally, first contact with an object was usually established by the central third of the arm and in arm contact sequences neighboring arms were the most likely to follow an arm already touching the object. Although results point towards strong eye/arm coordination, we did not find lateralized behavior in this experiment. Results are discussed from a neuro-anatomical, behavioral and ecological perspective.
Design and fabrication of a freeform phase plate for high-order ocular aberration correction
NASA Astrophysics Data System (ADS)
Yi, Allen Y.; Raasch, Thomas W.
2005-11-01
In recent years it has become possible to measure and in some instances to correct the high-order aberrations of human eyes. We have investigated the correction of wavefront error of human eyes by using phase plates designed to compensate for that error. The wavefront aberrations of the four eyes of two subjects were experimentally determined, and compensating phase plates were machined with an ultraprecision diamond-turning machine equipped with four independent axes. A slow-tool servo freeform trajectory was developed for the machine tool path. The machined phase-correction plates were measured and compared with the original design values to validate the process. The position of the phase-plate relative to the pupil is discussed. The practical utility of this mode of aberration correction was investigated with visual acuity testing. The results are consistent with the potential benefit of aberration correction but also underscore the critical positioning requirements of this mode of aberration correction. This process is described in detail from optical measurements, through machining process design and development, to final results.
In vivo DNA deletion assay to detect environmental and genetic predisposition to cancer.
Reliene, Ramune; Bishop, Alexander J R; Aubrecht, Jiri; Schiestl, Robert H
2004-01-01
Large-scale genomic rearrangements such as DNA deletions play a role in the etiology of cancer. The frequency of DNA deletions can be elevated by exposure to carcinogens or by mutations in genes involved in the maintenance of genomic integrity. The in vivo DNA deletion assay allows a visual detection of deletion events within the pink-eyed unstable (pun) locus in developing mouse embryos. A deletion of one copy of a duplicated 70-kb DNA fragment within the pun locus restores the pink-eyed dilute (p) gene, which encodes a protein responsible for the assembly of a black color melanin complex. Deletion events occurring in premelanocytes cause visible black patches (fur-spots) on the light gray fur of offspring and black pigmented cells (eye-spots) on the unpigmented retinal pigment epithelium (RPE). In the fur-spot assay, 10-d-old pups are observed for black spots on the fur. In the eye-spot assay, mice are sacrificed at d 20, eyes are removed, and the wholemount RPE slides are prepared for eye-spot analysis. The frequency, size, and position relative to the optic nerve of the eye-spots are determined. This assay can be used to study the effect of environmental chemicals and physical agents as well as the genetic control of DNA deletions in vivo.
Premotor neurons encode torsional eye velocity during smooth-pursuit eye movements
NASA Technical Reports Server (NTRS)
Angelaki, Dora E.; Dickman, J. David
2003-01-01
Responses to horizontal and vertical ocular pursuit and head and body rotation in multiple planes were recorded in eye movement-sensitive neurons in the rostral vestibular nuclei (VN) of two rhesus monkeys. When tested during pursuit through primary eye position, the majority of the cells preferred either horizontal or vertical target motion. During pursuit of targets that moved horizontally at different vertical eccentricities or vertically at different horizontal eccentricities, eye angular velocity has been shown to include a torsional component the amplitude of which is proportional to half the gaze angle ("half-angle rule" of Listing's law). Approximately half of the neurons, the majority of which were characterized as "vertical" during pursuit through primary position, exhibited significant changes in their response gain and/or phase as a function of gaze eccentricity during pursuit, as if they were also sensitive to torsional eye velocity. Multiple linear regression analysis revealed a significant contribution of torsional eye movement sensitivity to the responsiveness of the cells. These findings suggest that many VN neurons encode three-dimensional angular velocity, rather than the two-dimensional derivative of eye position, during smooth-pursuit eye movements. Although no clear clustering of pursuit preferred-direction vectors along the semicircular canal axes was observed, the sensitivity of VN neurons to torsional eye movements might reflect a preservation of similar premotor coding of visual and vestibular-driven slow eye movements for both lateral-eyed and foveate species.
Barta, András; Horváth, Gábor
2003-12-01
The apparent position, size, and shape of aerial objects viewed binocularly from water change as a result of the refraction of light at the water surface. Earlier studies of the refraction-distorted structure of the aerial binocular visual field of underwater observers were restricted to either vertically or horizontally oriented eyes. Here we calculate the position of the binocular image point of an aerial object point viewed by two arbitrarily positioned underwater eyes when the water surface is flat. Assuming that binocular image fusion is performed by appropriate vergent eye movements to bring the object's image onto the foveae, the structure of the aerial binocular visual field is computed and visualized as a function of the relative positions of the eyes. We also analyze two erroneous representations of the underwater imaging of aerial objects that have occurred in the literature. It is demonstrated that the structure of the aerial binocular visual field of underwater observers distorted by refraction is more complex than has been thought previously.
Eye Size at Birth in Prosimian Primates: Life History Correlates and Growth Patterns
Cummings, Joshua R.; Muchlinski, Magdalena N.; Kirk, E. Christopher; Rehorek, Susan J.; DeLeon, Valerie B.; Smith, Timothy D.
2012-01-01
Background Primates have large eyes relative to head size, which profoundly influence the ontogenetic emergence of facial form. However, growth of the primate eye is only understood in a narrow taxonomic perspective, with information biased toward anthropoids. Methodology/Principal Findings We measured eye and bony orbit size in perinatal prosimian primates (17 strepsirrhine taxa and Tarsius syrichta) to infer the extent of prenatal as compared to postnatal eye growth. In addition, multiple linear regression was used to detect relationships of relative eye and orbit diameter to life history variables. ANOVA was used to determine if eye size differed according to activity pattern. In most of the species, eye diameter at birth measures more than half of that for adults. Two exceptions include Nycticebus and Tarsius, in which more than half of eye diameter growth occurs postnatally. Ratios of neonate/adult eye and orbit diameters indicate prenatal growth of the eye is actually more rapid than that of the orbit. For example, mean neonatal transverse eye diameter is 57.5% of the adult value (excluding Nycticebus and Tarsius), compared to 50.8% for orbital diameter. If Nycticebus is excluded, relative gestation age has a significant positive correlation with relative eye diameter in strepsirrhines, explaining 59% of the variance in relative transverse eye diameter. No significant differences were found among species with different activity patterns. Conclusions/Significance The primate developmental strategy of relatively long gestations is probably tied to an extended period of neural development, and this principle appears to apply to eye growth as well. Our findings indicate that growth rates of the eye and bony orbit are disassociated, with eyes growing faster prenatally, and the growth rate of the bony orbit exceeding that of the eyes after birth. Some well-documented patterns of orbital morphology in adult primates, such as the enlarged orbits of nocturnal species, mainly emerge during postnatal development. PMID:22567127
Pearce, Jacqueline W; Galle, Laurence E; Kleiboeker, Steve B; Turk, James R; Schommer, Susan K; Dubielizig, Richard R; Mitchell, William J; Moore, Cecil P; Giuliano, Elizabeth A
2007-11-01
Equine recurrent uveitis (ERU) is the most frequent cause of blindness in horses worldwide. Leptospira has been implicated as an etiologic agent in some cases of ERU and has been detected in fresh ocular tissues of affected horses. The objective of this study was to determine the presence of Leptospira antigen and DNA in fixed equine ocular tissues affected with end-stage ERU. Sections of eyes from 30 horses were obtained. Controls included 1) 10 normal equine eyes and 2) 10 equine eyes with a nonrecurrent form of uveitis. The experimental group consisted of 10 eyes diagnosed with ERU based on clinical signs and histologic lesions. Sections were subjected to immunohistochemical staining with an array of rabbit anti-Leptospira polyclonal antibodies. DNA extractions were performed by using a commercial kit designed for fixed tissue. Real-time PCR analysis was completed on extracted DNA. The target sequence for PCR was designed from alignments of available Leptospira 16S rDNA partial sequences obtained from GenBank. Two of 10 test samples were positive for Leptospira antigen by immunohistochemical assay. Zero of 20 controls were positive for Leptospira antigen. All test samples and controls were negative for Leptospira DNA by real-time PCR analysis. Leptospira was detected at a lower frequency than that previously reported for fresh ERU-affected aqueous humor and vitreous samples. Leptospira is not frequently detectable in fixed ocular tissues of horses affected with ERU when using traditional immunohistochemical and real-time PCR techniques.
Omar, Artur; Marteinsdottir, Maria; Kadesjö, Nils; Fransson, Annette
2015-06-01
The International Commission on Radiological Protection (ICRP) has recommended that the occupational dose limit to the eye lens be substantially reduced. To ensure compliance with these recommendations, monitoring of the occupational eye lens dose is essential in certain hospital work environments. For assessment of the eye lens dose it is recommended to use a supplementary dosimeter placed at a position adjacent to the eye(s). Wearing a dosimeter at eye level can, however, be impractical and distributing and managing additional dosimeters over long periods of time is cumbersome and costly for large clinical sites. An attractive alternative is to utilize active personal dosimeters (APDs), which are routinely used by clinical staff for real-time monitoring of the personal dose equivalent rate (H(p)(10)). In this work, a formalism for the determination of eye lens dose from the response of such APD's worn on the chest is proposed and evaluated. The evaluation is based on both phantom and clinical measurements performed in an x-ray angiography suite for interventional cardiology. The main results show that the eye lens dose to the primary operator and to the assisting clinical staff can be conservatively estimated from the APD response as D(eye)(conductor) = 2.0 APD chest and D(eye)(assisting) = 1.0 APD chest, respectively. However, care should be exercised for particularly short assisting staff and if radiation protection shields are misused. These concerns can be greatly mitigated if the clinical staff are provided with adequate radiation protection training.
Ishizuka, K; Kashiwakura, M; Oiji, A
1998-05-01
In order to explore a possible association between psychiatric symptoms and eye movements, 32 patients with schizophrenia were examined using an eye mark recorder in combination with the Positive and Negative Syndrome Scale, and were compared with 32 controls. Four types of figures were presented to the subjects: geometrical figures, drawings, story drawings, and sentences. Mean eye fixation time was significantly longer and mean eye scanning length was significantly shorter for the patients than for controls, not only in response to the geometric figures, but also in response to the story drawings. Eye fixation time and scanning velocity were positively correlated with degrees of thought disturbance. The number of eye fixations, eye fixation time and scanning velocity were negatively correlated with degree of depressive tendency.
Determinants of ocular deviation in esotropic subjects under general anesthesia.
Daien, Vincent; Turpin, Chloé; Lignereux, François; Belghobsi, Riadh; Le Meur, Guylene; Lebranchu, Pierre; Pechereau, Alain
2013-01-01
The authors attempted to identify the determinants of ocular deviation in a population of patients with esotropia under general anesthesia. Forty-one patients with esotropia were included. Horizontal ocular deviation was evaluated by the photographic Hirschberg test both in the awakened state and under general anesthesia before surgery. Changes in ocular deviation were measured and a multivariate analysis was used to assess its clinical determinants. The mean age (± standard deviation [SD]) of study subjects was 13 ± 11 years and 51% were females. The mean spherical equivalent refraction of the right eye was 2.44 ± 2.50 diopters (D), with no significant difference between eyes (P = .26). The mean ocular deviation changed significantly, from 33.5 ± 12.5 prism diopters (PD) at preoperative examination to 8.8 ± 11.4 PD under general anesthesia (P = .0001). The changes in ocular deviation positively correlated with the pre-operative ocular deviation (correlation coefficient r = 0.59, P = .0001) and negatively correlated with patient age (correlation coefficient r = -0.53, P = .0001). These two determinants remained significant after multivariate adjustment of the following variables: preoperative ocular deviation; age; gender; spherical equivalent refraction; and number of previous strabismus surgeries (model r(2) = 0.49, P = .0001). The ocular position under general anesthesia was reported as a key factor in the surgical treatment of subjects with esotropia; therefore, its clinical determinants were assessed. The authors observed that preoperative ocular deviation and patient age were the main factors that influenced the ocular position under general anesthesia. Copyright 2013, SLACK Incorporated.
Verkicharla, Pavan K; Suheimat, Marwan; Mallen, Edward A H; Atchison, David A
2014-01-01
The eye rotation approach for measuring peripheral eye length leads to concern about whether the rotation influences results, such as through pressure exerted by eyelids or extra-ocular muscles. This study investigated whether this approach is valid. Peripheral eye lengths were measured with a Lenstar LS 900 biometer for eye rotation and no-eye rotation conditions (head rotation for horizontal meridian and instrument rotation for vertical meridian). Measurements were made for 23 healthy young adults along the horizontal visual field (± 30°) and, for a subset of eight participants along the vertical visual field (± 25°). To investigate the influence of the duration of eye rotation, for six participants measurements were made at 0, 60, 120, 180 and 210 s after eye rotation to ± 30° along horizontal and vertical visual fields. Peripheral eye lengths were not significantly different for the conditions along the vertical meridian (F1,7 = 0.16, p = 0.71). The peripheral eye lengths for the conditions were significantly different along the horizontal meridian (F1,22 = 4.85, p = 0.04), although not at individual positions (p ≥ 0.10) and were not important. There were no apparent differences between the emmetropic and myopic groups. There was no significant change in eye length at any position after maintaining position for 210 s. Eye rotation and no-eye rotation conditions were similar for measuring peripheral eye lengths along horizontal and vertical visual field meridians at ± 30° and ± 25°, respectively. Either condition can be used to estimate retinal shape from peripheral eye lengths. © 2013 The Authors Ophthalmic & Physiological Optics © 2013 The College of Optometrists.
High-resolution eye tracking using V1 neuron activity
McFarland, James M.; Bondy, Adrian G.; Cumming, Bruce G.; Butts, Daniel A.
2014-01-01
Studies of high-acuity visual cortical processing have been limited by the inability to track eye position with sufficient accuracy to precisely reconstruct the visual stimulus on the retina. As a result, studies on primary visual cortex (V1) have been performed almost entirely on neurons outside the high-resolution central portion of the visual field (the fovea). Here we describe a procedure for inferring eye position using multi-electrode array recordings from V1 coupled with nonlinear stimulus processing models. We show that this method can be used to infer eye position with one arc-minute accuracy – significantly better than conventional techniques. This allows for analysis of foveal stimulus processing, and provides a means to correct for eye-movement induced biases present even outside the fovea. This method could thus reveal critical insights into the role of eye movements in cortical coding, as well as their contribution to measures of cortical variability. PMID:25197783
Yang, Jee Myung; Park, Sang Woo; Ji, Yong Sok; Kim, Jaeryung; Yoo, Chungkwon; Heo, Hwan
2017-04-20
To investigate postural effects on intraocular pressure (IOP) and ocular perfusion pressure (OPP) in patients with non-arteritic ischemic optic neuropathy (NAION). IOP and blood pressure (BP) were measured in 20 patients with unilateral NAION 10 min after changing to each of the following positions sequentially: sitting, supine, right lateral decubitus position (LDP), supine, left LDP, and supine. IOP was measured using a rebound tonometer and OPP was calculated using formulas based on mean BP. The dependent LDP (DLDP) was defined as the position when the eye of interest (affected or unaffected eye) was placed on the dependent side in the LDP. IOPs were significantly higher (P = 0.020) and OPPs were significantly lower (P = 0.041) in the affected eye compare with the unaffected eye, with the affected eye in DLDP. Compared with the mean IOP of the unaffected eyes, the mean IOP of the affected eyes increased significantly (+2.9 ± 4.4 versus +0.7 ± 3.1 mmHg, respectively; P = 0.003) and the mean OPP decreased significantly (-6.7 ± 9.4 versus -4.9 ± 8.0 mmHg, respectively; P = 0.022) after changing positions from supine to DLDP. In addition, changing position from supine to DLDP showed significantly larger absolute changes in IOP (4.13 ± 3.19 mmHg versus 2.51 ± 1.92 mmHg, respectively; P = 0.004) and OPP (9.86 ± 5.69 mmHg versus 7.50 ± 5.49 mmHg, respectively; P = 0.009) in the affected eye compared with the unaffected eye. In the affected eye, there was a significant positive correlation between absolute change in IOP and OPP when changing position from supine to DLDP (Rho = 0.512, P = 0.021). A postural change from supine to DLDP caused significant fluctuations in IOP and OPP of the affected eye, and may significantly increase IOP and decrease OPP. Posture-induced IOP changes may be a predisposing factor for NAION development.
Zhang, Qing; Yang, Hua; Kang, Shin J.; Wang, Yanggan; Wang, Geoffrey D.; Coulthard, Tonya
2011-01-01
Purpose. To evaluate the usefulness of in vivo imaging of uveal melanoma in mice using high-frequency contrast-enhanced ultrasound (HF-CE-US) with 2D or 3D modes and to correlate the sonographic findings with histopathologic characteristics. Methods. Fourteen 12-week-old C57BL6 mice were inoculated into their right eyes with aliquots of 5 × 105/2.5 μL B16LS9 melanoma cells and were randomly assigned to either of two groups. At 7 days after inoculation, tumor-bearing eyes in group 1 (n = 8) were imaged using HF-CE-US to determine the 2D tumor size and relative blood volume; eyes in group 2 (n = 6) were imaged by 3D microbubble contrast-enhanced ultrasound, and the tumor volume was determined. Histologic tumor burden was quantified in enucleated eyes by image processing software, and microvascular density was determined by counting von Willebrand factor-positive vascular channels. Ultrasound images were evaluated and compared with histopathologic findings. Results. Using HF-CE-US, melanomas were visualized as relatively hyperechoic regions. The intraobserver variability of sonographic measurements was 9.65% ± 7.89%, and the coefficient of variation for multiple measurements was 7.33% ± 5.71%. The correlation coefficient of sonographic volume or size and histologic area was 0.71 (P = 0.11) and 0.79 (P = 0.32). The relative blood volume within the tumor demonstrated sonographically correlated significantly with histologic tumor vascularity (r = 0.83; P < 0.001). Conclusions. There was a positive linear correlation between sonographic tumor measurements and histologic tumor burden in the mouse ocular melanoma model. Contrast-enhanced intensity corresponded with microvascular density and blood volume. HF-CE-US is a real-time, noninvasive, reliable method for in vivo evaluation of experimental intraocular melanoma tumor area and relative blood volume. PMID:21245408
Genead, Mohamed A; Fishman, Gerald A; Walia, Saloni
2010-02-01
To determine the efficacy of sustained topical therapy with dorzolamide hydrochloride, 2%, on visual acuity and cystic macular lesions in patients with juvenile X-linked retinoschisis (XLRS). Retrospective analysis. University hospital, tertiary care referral center. Twenty-nine eyes of 15 patients with XLRS receiving treatment with the topical dorzolamide formulation for 4 to 41 months were enrolled. Changes in visual acuity, cystic macular lesions, and central foveal zone thickness on optical coherence tomography during follow-up for the duration of treatment. Among the 15 patients with XLRS, 20 eyes (69%) of 11 patients showed a positive response to treatment. Five of the 20 eyes (25%) in 3 of the 11 patients showed an initial response and a subsequent rebound of macular cysts. In 4 eyes (14%) of 3 patients, there was no response to treatment, but the macular cysts did not worsen compared with the baseline level. In 5 additional eyes (17%) of 4 patients, there was no response to treatment, and the macular cysts worsened when compared with the baseline level. Sixteen eyes (55%) of 12 patients had improvement in best-corrected visual acuity by at least 7 letters in at least 1 eye at the most recent follow-up visit. Seventeen eyes (59%) of 10 patients showed a reduction in the central foveal zone thickness in at least 1 eye when compared with the pretreatment level. Patients with XLRS have the potential to experience a beneficial effect from sustained treatment with dorzolamide, 2%.
Principi, S; Farah, J; Ferrari, P; Carinou, E; Clairand, I; Ginjaume, M
2016-09-01
This paper aims to provide some practical recommendations to reduce eye lens dose for workers exposed to X-rays in interventional cardiology and radiology and also to propose an eye lens correction factor when lead glasses are used. Monte Carlo simulations are used to study the variation of eye lens exposure with operator position, height and body orientation with respect to the patient and the X-ray tube. The paper also looks into the efficiency of wraparound lead glasses using simulations. Computation results are compared with experimental measurements performed in Spanish hospitals using eye lens dosemeters as well as with data from available literature. Simulations showed that left eye exposure is generally higher than the right eye, when the operator stands on the right side of the patient. Operator height can induce a strong dose decrease by up to a factor of 2 for the left eye for 10-cm-taller operators. Body rotation of the operator away from the tube by 45°-60° reduces eye exposure by a factor of 2. The calculation-based correction factor of 0.3 for wraparound type lead glasses was found to agree reasonably well with experimental data. Simple precautions, such as the positioning of the image screen away from the X-ray source, lead to a significant reduction of the eye lens dose. Measurements and simulations performed in this work also show that a general eye lens correction factor of 0.5 can be used when lead glasses are worn regardless of operator position, height and body orientation. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Yabsley, Michael J; Jordan, Carly N; Mitchell, Sheila M; Norton, Terry M; Lindsay, David S
2007-03-15
In the current study, we determined the seroprevalence of Toxoplasma gondii, Sarcocystis neurona, and Encephalitozoon cuniculi in three species of lemurs from St. Catherines Island, Georgia. Serum samples were tested from 52 ring-tailed lemurs (Lemur catta), six blue-eyed black lemurs (Eulemur macaco flavifrons), and four black and white ruffed lemurs (Varecia variegata variegata) using an agglutination assay. Three ring-tailed lemurs (5.8%) were positive for T. gondii (titer of 1:50); one ring-tailed lemur (1.9%) and one black and white ruffed lemur (25%) were positive for S. neurona (titers of 1:1000); and one ring-tailed lemur (1.9%) was positive for E. cuniculi (titer of 1:400). All blue-eyed black lemurs were negative for antibodies to T. gondii, S. neurona, and E. cuniculi. This is the first detection of antibodies to T. gondii in ring-tailed lemurs and antibodies to S. neurona and E. cuniculi in any species of prosimian.
Therapeutic effects of topical doxycycline in a benzalkonium chloride-induced mouse dry eye model.
Zhang, Zhen; Yang, Wen-Zhao; Zhu, Zhen-Zhen; Hu, Qian-Qian; Chen, Yan-Feng; He, Hui; Chen, Yong-Xiong; Liu, Zu-Guo
2014-05-06
We investigated the therapeutic effects and underlying mechanisms of topical doxycycline in a benzalkonium chloride (BAC)-induced mouse dry eye model. Eye drops containing 0.025%, 0.1% doxycycline or solvent were administered to a BAC-induced dry eye model four times daily. The clinical evaluations, including tear break-up time (BUT), fluorescein staining, inflammatory index, and tear volume, were performed on days 0, 1, 4, 7, and 10. Global specimens were collected on day 10 and processed for immunofluorescent staining, TUNEL, and periodic acid-Schiff assay. The levels of inflammatory mediators in the corneas were determined by real-time PCR. The total and phosphorylated nuclear factor-κB (NF-κB) were detected by Western blot. Both 0.025% and 0.1% doxycycline treatments resulted in increased BUT, lower fluorescein staining scores, and inflammatory index on days 4, 7, and 10, while no significant change in tear volume was observed. The 0.1% doxycycline-treated group showed more improvements in decreasing fluorescein staining scores, increasing Ki-67-positive cells, and decreasing TUNEL- and keratin-10-positive cells than other groups. The mucin-filled goblet cells in conjunctivas were increased, and the expression of CD11b and levels of matrix metalloproteinase-9, IL-1β, IL-6, TNF-α, macrophage inflammatory protein-2, and cytokine-induced neutrophil chemoattractant in corneas were decreased in both doxycycline-treated groups. In addition, doxycycline significantly reduced the phosphorylation of NF-κB activated in the BAC-treated corneas. Topical doxycycline showed clinical improvements and alleviated ocular surface inflammation on BAC-induced mouse dry eye, suggesting a potential as an anti-inflammatory agent in the clinical treatment of dry eye.
Yang, Chen-Yuan Charlie; Liu, Ye; Lu, Zhaozeng; Ren, Ruiyi; Gong, Haiyan
2013-08-28
To determine the effect of Y27632, a Rho-kinase inhibitor on aqueous outflow facility, flow pattern, and juxtacanalicular tissue (JCT)/trabecular meshwork (TM) morphology in human eyes. Sixteen enucleated human eyes were perfused with PBS plus glucose (GPBS) at 15 mm Hg to establish the baseline outflow facility. Six eyes were perfused for short-duration (30 minute) with either 50 μM Y27632 or GPBS (n = 3 per group). Ten eyes were perfused for long duration (3 hours) with either 50 μM Y27632 or GPBS (n = 5 per group). Outflow pattern was labeled using fluorescent microspheres, and effective filtration length (EFL) was measured. Morphologic changes and their relationship to EFL and facility were analyzed. Outflow facility significantly increased after short-duration perfusion with Y27632 compared with its own baseline (P = 0.03), but did not reach statistical significance compared with its controls (P = 0.07). Outflow facility (P = 0.01) and EFL (P < 0.05) were significantly increased after long-duration perfusion with Y27632 compared with its controls. Increases in outflow facility and EFL demonstrated a positive correlation. Morphologically, the TM and JCT of high-tracer regions were more expanded compared with low-tracer regions. A significant increase in JCT thickness was found in the long-duration Y27632 group compared with its control group (10.0 vs. 8.0 μm, P < 0.01). Y27632 increases outflow facility in human eyes. This increase correlates positively with an increase in EFL, which is associated with an increased expansion in the JCT. Our data suggest that EFL could serve as a novel parameter to correlate with outflow facility.
A holographic waveguide based eye tracker
NASA Astrophysics Data System (ADS)
Liu, Changgeng; Pazzucconi, Beatrice; Liu, Juan; Liu, Lei; Yao, Xincheng
2018-02-01
We demonstrated the feasibility of using holographic waveguide for eye tracking. A custom-built holographic waveguide, a 20 mm x 60 mm x 3 mm flat glass substrate with integrated in- and out-couplers, was used for the prototype development. The in- and out-couplers, photopolymer films with holographic fringes, induced total internal reflection in the glass substrate. Diffractive optical elements were integrated into the in-coupler to serve as an optical collimator. The waveguide captured images of the anterior segment of the eye right in front of it and guided the images to a processing unit distant from the eye. The vector connecting the pupil center (PC) and the corneal reflex (CR) of the eye was used to compute eye position in the socket. An eye model, made of a high quality prosthetic eye, was used prototype validation. The benchtop prototype demonstrated a linear relationship between the angular eye position and the PC/CR vector over a range of 60 horizontal degrees and 30 vertical degrees at a resolution of 0.64-0.69 degrees/pixel by simple pixel count. The uncertainties of the measurements at different angular positions were within 1.2 pixels, which indicated that the prototype exhibited a high level of repeatability. These results confirmed that the holographic waveguide technology could be a feasible platform for developing a wearable eye tracker. Further development can lead to a compact, see-through eye tracker, which allows continuous monitoring of eye movement during real life tasks, and thus benefits diagnosis of oculomotor disorders.
Abnormal Fixational Eye Movements in Amblyopia.
Shaikh, Aasef G; Otero-Millan, Jorge; Kumar, Priyanka; Ghasia, Fatema F
2016-01-01
Fixational saccades shift the foveal image to counteract visual fading related to neural adaptation. Drifts are slow eye movements between two adjacent fixational saccades. We quantified fixational saccades and asked whether their changes could be attributed to pathologic drifts seen in amblyopia, one of the most common causes of blindness in childhood. Thirty-six pediatric subjects with varying severity of amblyopia and eleven healthy age-matched controls held their gaze on a visual target. Eye movements were measured with high-resolution video-oculography during fellow eye-viewing and amblyopic eye-viewing conditions. Fixational saccades and drifts were analyzed in the amblyopic and fellow eye and compared with controls. We found an increase in the amplitude with decreased frequency of fixational saccades in children with amblyopia. These alterations in fixational eye movements correlated with the severity of their amblyopia. There was also an increase in eye position variance during drifts in amblyopes. There was no correlation between the eye position variance or the eye velocity during ocular drifts and the amplitude of subsequent fixational saccade. Our findings suggest that abnormalities in fixational saccades in amblyopia are independent of the ocular drift. This investigation of amblyopia in pediatric age group quantitatively characterizes the fixation instability. Impaired properties of fixational saccades could be the consequence of abnormal processing and reorganization of the visual system in amblyopia. Paucity in the visual feedback during amblyopic eye-viewing condition can attribute to the increased eye position variance and drift velocity.
Abnormal Fixational Eye Movements in Amblyopia
Shaikh, Aasef G.; Otero-Millan, Jorge; Kumar, Priyanka; Ghasia, Fatema F.
2016-01-01
Purpose Fixational saccades shift the foveal image to counteract visual fading related to neural adaptation. Drifts are slow eye movements between two adjacent fixational saccades. We quantified fixational saccades and asked whether their changes could be attributed to pathologic drifts seen in amblyopia, one of the most common causes of blindness in childhood. Methods Thirty-six pediatric subjects with varying severity of amblyopia and eleven healthy age-matched controls held their gaze on a visual target. Eye movements were measured with high-resolution video-oculography during fellow eye-viewing and amblyopic eye-viewing conditions. Fixational saccades and drifts were analyzed in the amblyopic and fellow eye and compared with controls. Results We found an increase in the amplitude with decreased frequency of fixational saccades in children with amblyopia. These alterations in fixational eye movements correlated with the severity of their amblyopia. There was also an increase in eye position variance during drifts in amblyopes. There was no correlation between the eye position variance or the eye velocity during ocular drifts and the amplitude of subsequent fixational saccade. Our findings suggest that abnormalities in fixational saccades in amblyopia are independent of the ocular drift. Discussion This investigation of amblyopia in pediatric age group quantitatively characterizes the fixation instability. Impaired properties of fixational saccades could be the consequence of abnormal processing and reorganization of the visual system in amblyopia. Paucity in the visual feedback during amblyopic eye-viewing condition can attribute to the increased eye position variance and drift velocity. PMID:26930079
Dong, Ying; Huang, Yi-Fei; Liu, Qian; DU, Gai-Ping
2011-05-01
To investigate the clinical and histopathologic features of the superficial tissue proliferation (STP) following the implantation of MICOF keratoprosthesis, and to analyze the formation and treatment of STP. Retrospective study. Eighty-five patients (85 eyes) received MICOF keratoprosthesis surgery from January 2000 through December 2009 in General Hospital of PLA, which included 72 males and 13 females. The mean age of the patients was (45 ± 15) years. Preoperative diagnoses were ocular burn (56 eyes), end-stage of autoimmune dry eye (14 eyes), severe ocular trauma (10 eyes) and repeated graft failure (5 eyes). Postoperatively, STPs of Kpro were observed and treated. The membranes anterior to the optical cylinder were removed and investigated by histological and immunohistochemical methods, and anterior segment specimens from normal eyes were taken as control. Twenty-two (26%) patients presented STP during the follow-up, and proliferations occurred ranging from 2 to 63 months (median, 7 months). The incident rates of STP were 34% (19/56 eyes) in burned eyes, 14% (2/14 eyes) in end-stage dry eye, 10% (1/10 eyes) in severe mechanical ocular trauma, and none in repeated grafts failure. Difference among four groups did not arrive significance statistically (χ(2) = 5.93, P = 0.11). The epithelial proliferations were observed in 11 patients, which were removed easily. To prevent from recurrence, the height of the cylinder was adjusted. Other 4 patients underwent ultra-high frequency ocular surface plastic operation and 7 patients received membranectomy. Histologically, the superficial proliferative membrane was composed of proliferative epithelium and fibrovascular tissue incorporating inflammatory cells. The immunohistochemical staining demonstrated the expression of PCNA increased in the epithelium, compared with control cornea and conjunctiva. Many vimentin-positive fibroblasts and a few α-SMA-positive myofibroblasts presented in the interstitial tissue, and the numbers of CD45RO-positive T cells, CD11c-positive dendritic cells, and CD68-positive macrophages were increased in proliferative membranes. The tissue proliferation around optical cylinder results in membrane formation anterior to the Kpro. The excessive inflammation at the prosthesis-corneal junction and the unsuited height of the optical cylinder might have been the main reasons of STP.
Postural Stability When Leaning from Perceived Upright
NASA Technical Reports Server (NTRS)
Vanya, Robert D.; Grounds, John F.; Wood, Scott J.
2011-01-01
The transition between quiet stance and gait requires the volitional movement of one?s center of mass (COM) toward a limit of stability (LOS). The goal of this study was to measure the effect of leaning from perceived upright on postural stability when voluntarily maintaining fixed stance positions and during perturbations of the support surface. The COM was derived from force plate data in 12 healthy subjects while standing with feet positioned so that lateral base of support was equal to foot length. For all conditions, arms were folded and subjects were instructed to lean without bending at the hips or lifting their feet. The LOS was determined during maximal voluntary leans with eyes open and closed. The COM was then displayed on a monitor located in front of the subject. Subjects were visually guided to lean toward a target position, maintain this position for 10s, return to upright, and then repeat the same targeted lean maneuver with eyes closed. Targets were randomly presented at 2? in 8 directions and between 2-6? in these same directions according to the asymmetric LOS. Subjects were then verbally guided to lean between 2? back and 4? forward prior to a perturbation of the support surface in either a forward or backward direction. The average LOS was 5.8? forward, 2.9? back, and 4.8? in left/right directions, with no significant difference between eyes open and closed. Center of pressure (COP) velocity increased as subjects maintained fixed stance positions farther from upright, with increased variability during eyes closed conditions. The time to stability and COP path length increased as subjects leaned opposite to the direction of the support surface perturbations. We conclude that postural stability is compromised as subjects lean away from perceived upright, except for perturbations that induce sway in the direction opposite the lean. The asymmetric LOS relative to perceived upright favors postural stability for COM movements in the forward direction.
Automated nystagmus analysis. [on-line computer technique for eye data processing
NASA Technical Reports Server (NTRS)
Oman, C. M.; Allum, J. H. J.; Tole, J. R.; Young, L. R.
1973-01-01
Several methods have recently been used for on-line analysis of nystagmus: A digital computer program has been developed to accept sampled records of eye position, detect fast phase components, and output cumulative slow phase position, continuous slow phase velocity, instantaneous fast phase frequency, and other parameters. The slow phase velocity is obtained by differentiation of the calculated cumulative position rather than the original eye movement record. Also, a prototype analog device has been devised which calculates the velocity of the slow phase component during caloric testing. Examples of clinical and research eye movement records analyzed with these devices are shown.
Turner, Daniel C.; Samuels, Brian C.; Huisingh, Carrie; Girkin, Christopher A.
2017-01-01
Purpose To study the effect and time course of body position changes on IOP in nonhuman primates. Methods We recorded continuous bilateral IOP measurements with a wireless telemetry implant in three rhesus macaques in seven different body positions. IOP measurements were acquired in the seated-upright, standing, prone, supine, right and left lateral decubitus positions (LDPs), and head-down inverted positions. Continuous IOP was recorded for 90 seconds in each position before returning to a supine reference position until IOP stabilized; measurements were averaged after IOP stabilized at each position. Results Head-down inversion increased IOP an average of 8.9 mm Hg, compared to the supine reference. In the LDP, IOP decreased an average of 0.5 mm Hg in the nondependent eye (i.e., the higher eye), while the fellow dependent (i.e., lower) eye increased an average of 0.5 mm Hg, compared to supine reference. Standing and seated positions decreased IOP 1.5 and 2.2 mm Hg, respectively, compared with supine reference. IOP changes occurred within 4 to 15 seconds of a body position change, and timing was affected by the speed at which body position was changed. Compared to the IOP in the supine position, the IOP in the inverted, prone, and seated positions was significantly different (P = 0.0313 for all). The IOP in the standing position was not statistically different from the IOP in the supine position (P = 0.094). In addition, the IOP was significantly different between the nondependent eye and the dependent eye in the LDPs compared to the supine position (P = 0.0313). Conclusions Body position has a significant effect on IOP and those changes persist over time. PMID:29228251
Dynamic optometer. [for electronic recording of human lens anterior surface
NASA Technical Reports Server (NTRS)
Wilson, D. C.
1974-01-01
A dynamic optometer that electronically records the position of the anterior surface of the human lens is described. The geometrical optics of the eye and optometer, and the scattering of light from the lens, are closely examined to determine the optimum conditions for adjustment of the instrument. The light detector and associated electronics are also considered, and the operating conditions for obtaining the best signal-to-noise ratio are determined.
ERIC Educational Resources Information Center
Crookes, Kate; Hayward, William G.
2012-01-01
Presenting a face inverted (upside down) disrupts perceptual sensitivity to the spacing between the features. Recently, it has been shown that this disruption is greater for vertical than horizontal changes in eye position. One explanation for this effect proposed that inversion disrupts the processing of long-range (e.g., eye-to-mouth distance)…
Oculomotor control of primary eye position discriminates between translation and tilt
NASA Technical Reports Server (NTRS)
Hess, B. J.; Angelaki, D. E.
1999-01-01
We have previously shown that fast phase axis orientation and primary eye position in rhesus monkeys are dynamically controlled by otolith signals during head rotations that involve a reorientation of the head relative to gravity. Because of the inherent ambiguity associated with primary otolith afferent coding of linear accelerations during head translation and tilts, a similar organization might also underlie the vestibulo-ocular reflex (VOR) during translation. The ability of the oculomotor system to correctly distinguish translational accelerations from gravity in the dynamic control of primary eye position has been investigated here by comparing the eye movements elicited by sinusoidal lateral and fore-aft oscillations (0.5 Hz +/- 40 cm, equivalent to +/- 0.4 g) with those during yaw rotations (180 degrees/s) about a vertically tilted axis (23.6 degrees). We found a significant modulation of primary eye position as a function of linear acceleration (gravity) during rotation but not during lateral and fore-aft translation. This modulation was enhanced during the initial phase of rotation when there was concomitant semicircular canal input. These findings suggest that control of primary eye position and fast phase axis orientation in the VOR are based on central vestibular mechanisms that discriminate between gravity and translational head acceleration.
Dong, Nuo; Yang, Fan; Lin, Zhirong; Shang, Xumin; Li, Cheng
2014-01-01
Objective To explore meibomian gland dysfunction (MGD) may determine the severity of dry eye conditions in visual display terminal (VDT) workers. Methodology Prospective, case-control study carried out in China.106 eyes of 53 patients (VDT work time >4 hour per day) were recruited as the Long time VDT group; 80 eyes of 40 control subjects (VDT work time ≤4 hour per day) served as the Short time VDT group. A questionnaire of Ocular Surface Disease Index (OSDI) and multiple tests were performed. Three dry eye tests: tear film breakup time (BUT), corneal fluorescein staining, Schirmer I test; and three MGD parameters: lid margin abnormality score, meibum expression assessment (meibum score), and meibomian gland dropout degree (meiboscore) using Keratograph 5 M. Principal Findings OSDI and corneal fluorescein score were significantly higher while BUT was dramatically shorter in the long time VDT group than the short time VDT group. However, the average of Schirmer tear volumes was in normal ranges in both groups. Interestingly, the three MGD parameters were significantly higher in the long time VDT group than the short time one (P<0.0001). When 52 eyes with Schirmer <10 mm and 54 eyes with Schirmer ≥10 mm were separated from the long time VDT workers, no significant differences were found between the two subgroups in OSDI, fluorescein staining and BUT, as well as the three MGD parameters. All three MGD parameters were positively correlated with VDT working time (P<0.0001) and fluorescein scores (P<0.0001), inversely correlated with BUT (P<0.05), but not correlated with Schirmer tear volumes in the VDT workers. Conclusions Our findings suggest that a malfunction of meibomian glands is associated with dry eye patients in long term VDT workers with higher OSDI scores whereas some of those patients presenting a normal tear volume. PMID:25144638
Bakst, Leah; Fleuriet, Jérome
2017-01-01
Neurons in the smooth eye movement subregion of the frontal eye field (FEFsem) are known to play an important role in voluntary smooth pursuit eye movements. Underlying this function are projections to parietal and prefrontal visual association areas and subcortical structures, all known to play vital but differing roles in the execution of smooth pursuit. Additionally, the FEFsem has been shown to carry a diverse array of signals (e.g., eye velocity, acceleration, gain control). We hypothesized that distinct subpopulations of FEFsem neurons subserve these diverse functions and projections, and that the relative weights of retinal and extraretinal signals could form the basis for categorization of units. To investigate this, we used a step-ramp tracking task with a target blink to determine the relative contributions of retinal and extraretinal signals in individual FEFsem neurons throughout pursuit. We found that the contributions of retinal and extraretinal signals to neuronal activity and behavior change throughout the time course of pursuit. A clustering algorithm revealed three distinct neuronal subpopulations: cluster 1 was defined by a higher sensitivity to eye velocity, acceleration, and retinal image motion; cluster 2 had greater activity during blinks; and cluster 3 had significantly greater eye position sensitivity. We also performed a comparison with a sample of medial superior temporal neurons to assess similarities and differences between the two areas. Our results indicate the utility of simple tests such as the target blink for parsing the complex and multifaceted roles of cortical areas in behavior. NEW & NOTEWORTHY The frontal eye field (FEF) is known to play a critical role in volitional smooth pursuit, carrying a variety of signals that are distributed throughout the brain. This study used a novel application of a target blink task during step ramp tracking to determine, in combination with a clustering algorithm, the relative contributions of retinal and extraretinal signals to FEF activity and the extent to which these contributions could form the basis for a categorization of neurons. PMID:28202571
Visual and linguistic determinants of the eyes' initial fixation position in reading development.
Ducrot, Stéphanie; Pynte, Joël; Ghio, Alain; Lété, Bernard
2013-03-01
Two eye-movement experiments with one hundred and seven first- through fifth-grade children were conducted to examine the effects of visuomotor and linguistic factors on the recognition of words and pseudowords presented in central vision (using a variable-viewing-position technique) and in parafoveal vision (shifted to the left or right of a central fixation point). For all groups of children, we found a strong effect of stimulus location, in both central and parafoveal vision. This effect corresponds to the children's apparent tendency, for peripherally located targets, to reach a position located halfway between the middle and the left edge of the stimulus (preferred viewing location, PVL), whether saccading to the right or left. For centrally presented targets, refixation probability and lexical-decision time were the lowest near the word's center, suggesting an optimal viewing position (OVP). The viewing-position effects found here were modulated (1) by print exposure, both in central and parafoveal vision; and (2) by the intrinsic qualities of the stimulus (lexicality and word frequency) for targets in central vision but not for parafoveally presented targets. Copyright © 2013 Elsevier B.V. All rights reserved.
Extralenticular and lenticular aspects of accommodation and presbyopia in human versus monkey eyes.
Croft, Mary Ann; McDonald, Jared P; Katz, Alexander; Lin, Ting-Li; Lütjen-Drecoll, Elke; Kaufman, Paul L
2013-07-26
To determine if the accommodative forward movements of the vitreous zonule and lens equator occur in the human eye, as they do in the rhesus monkey eye; to investigate the connection between the vitreous zonule posterior insertion zone and the posterior lens equator; and to determine which components-muscle apex width, lens thickness, lens equator position, vitreous zonule, circumlental space, and/or other intraocular dimensions, including those stated in the objectives above-are most important in predicting accommodative amplitude and presbyopia. Accommodation was induced pharmacologically in 12 visually normal human subjects (ages 19-65 years) and by midbrain electrical stimulation in 11 rhesus monkeys (ages 6-27 years). Ultrasound biomicroscopy imaged the entire ciliary body, anterior and posterior lens surfaces, and the zonule. Relevant distances were measured in the resting and accommodated eyes. Stepwise regression analysis determined which variables were the most important predictors. The human vitreous zonule and lens equator move forward (anteriorly) during accommodation, and their movements decline with age, as in the monkey. Over all ages studied, age could explain accommodative amplitude, but not as well as accommodative lens thickening and resting muscle apex thickness did together. Accommodative change in distances between the vitreous zonule insertion zone and the posterior lens equator or muscle apex were important for predicting accommodative lens thickening. Our findings quantify the movements of the zonule and ciliary muscle during accommodation, and identify their age-related changes that could impact the optical change that occurs during accommodation and IOL function.
Intraoperative cyclorotation and pupil centroid shift during LASIK and PRK.
Narváez, Julio; Brucks, Matthew; Zimmerman, Grenith; Bekendam, Peter; Bacon, Gregory; Schmid, Kristin
2012-05-01
To determine the degree of cyclorotation and centroid shift in the x and y axis that occurs intraoperatively during LASIK and photorefractive keratectomy (PRK). Intraoperative cyclorotation and centroid shift were measured in 63 eyes from 34 patients with a mean age of 34 years (range: 20 to 56 years) undergoing either LASIK or PRK. Preoperatively, an iris image of each eye was obtained with the VISX WaveScan Wavefront System (Abbott Medical Optics Inc) with iris registration. A VISX Star S4 (Abbott Medical Optics Inc) laser was later used to measure cyclotorsion and pupil centroid shift at the beginning of the refractive procedure and after flap creation or epithelial removal. The mean change in intraoperative cyclorotation was 1.48±1.11° in LASIK eyes and 2.02±2.63° in PRK eyes. Cyclorotation direction changed by >2° in 21% of eyes after flap creation in LASIK and in 32% of eyes after epithelial removal in PRK. The respective mean intraoperative shift in the x axis and y axis was 0.13±0.15 mm and 0.17±0.14 mm, respectively, in LASIK eyes, and 0.09±0.07 mm and 0.10±0.13 mm, respectively, in PRK eyes. Intraoperative centroid shifts >100 μm in either the x axis or y axis occurred in 71% of LASIK eyes and 55% of PRK eyes. Significant changes in cyclotorsion and centroid shifts were noted prior to surgery as well as intraoperatively with both LASIK and PRK. It may be advantageous to engage iris registration immediately prior to ablation to provide a reference point representative of eye position at the initiation of laser delivery. Copyright 2012, SLACK Incorporated.
Detecting eye movements in dynamic environments.
Reimer, Bryan; Sodhi, Manbir
2006-11-01
To take advantage of the increasing number of in-vehicle devices, automobile drivers must divide their attention between primary (driving) and secondary (operating in-vehicle device) tasks. In dynamic environments such as driving, however, it is not easy to identify and quantify how a driver focuses on the various tasks he/she is simultaneously engaged in, including the distracting tasks. Measures derived from the driver's scan path have been used as correlates of driver attention. This article presents a methodology for analyzing eye positions, which are discrete samples of a subject's scan path, in order to categorize driver eye movements. Previous methods of analyzing eye positions recorded in a dynamic environment have relied completely on the manual identification of the focus of visual attention from a point of regard superimposed on a video of a recorded scene, failing to utilize information regarding movement structure in the raw recorded eye positions. Although effective, these methods are too time consuming to be easily used when the large data sets that would be required to identify subtle differences between drivers, under different road conditions, and with different levels of distraction are processed. The aim of the methods presented in this article are to extend the degree of automation in the processing of eye movement data by proposing a methodology for eye movement analysis that extends automated fixation identification to include smooth and saccadic movements. By identifying eye movements in the recorded eye positions, a method of reducing the analysis of scene video to a finite search space is presented. The implementation of a software tool for the eye movement analysis is described, including an example from an on-road test-driving sample.
Khan, Faisal Aziz; Niazi, Shafaq Pervez Khan; Khan, Assad Zaman
2017-09-01
To determine the relationship of the van Herick angle grading system with the level of iris insertion and peripheral iris configuration. Observational study. Eye department, Combined Military Hospital, Malir Cantt., Karachi, from May to October 2015. Sixty-five eyes of 65 patients were recruited. Anterior chamber depth at the temporal limbus was measured as a fraction of corneal section thickness using van Herick technique and graded on the standard 4-point scale of the van Herick grading system. Gonioscopy of the temporal quadrant was performed with a Posner 4 mirror goniolens and both the true level of iris insertion and peripheral iris configuration were recorded on a 4-point scale so as to equate with the van Herick 4-point grading system. Spearman's rho test was applied to determine the relationship of the van Herick grading system with level of iris root insertion and peripheral iris configuration. Amoderate positive correlation between van Herick grade and peripheral iris configuration was found which was statistically significant (rs=0.42, p < 0.001). Astatistically significant and moderate positive correlation was also detected between van Herick grade and the level of iris insertion (rs=0.45, p < 0.001). The van Herick grade has a moderately positive relationship with the peripheral iris configuration and true level of iris insertion.
Variations of pupil centration and their effects on video eye tracking.
Wildenmann, Ulrich; Schaeffel, Frank
2013-11-01
To evaluate measurement errors that are introduced in video eye tracking when pupil centration changes with pupil size. Software was developed under Visual C++ to track both pupil centre and corneal centre at 87 Hz sampling rate at baseline pupil sizes of 4.75 mm (800 lux room illuminance) and while pupil constrictions were elicited by a flashlight. Corneal centres were determined by a circle fit through the pixels detected at the corneal margin by an edge detection algorithm. Standard deviations for repeated measurements were ± 0.04 mm for horizontal pupil centre position and ± 0.04 mm for horizontal corneal centre positions and ±0.03 mm for vertical pupil centre position and ± 0.05 mm for vertical corneal centre position. Ten subjects were tested (five female, five male, age 25-58 years). At 4 mm pupil sizes, the pupils were nasally decentred relative to the corneal centre by 0.18 ± 0.19 mm in the right eyes and -0.14 ± 0.22 mm in the left eyes. Vertical decentrations were 0.30 ± 0.30 mm and 0.27 ± 0.29 mm, respectively, always in a superior direction. At baseline pupil sizes (the natural pupil sizes at 800 lux) of 4.75 ± 0.52 mm, the decentrations became less (right and left eyes: horizontal 0.17 ± 0.20 mm and -0.12 ± 0.22 mm, and vertical 0.26 ± 0.28 mm and 0.20 ± 0.25 mm). While pupil decentration changed minimally in eight of the subjects, it shifted considerably in two others. Averaged over all subjects, the shift of the pupil centre position per millimetre pupil constriction was not significant (right and left eyes: -0.03 ± 0.07 mm and 0.03 ± 0.04 mm nasally per mm pupil size change, respectively, and -0.04 ± 0.06 mm and -0.05 ± 0.12 mm superiorly). Direction and magnitude of the changes in pupil centration could not be predicted from the initial decentration at baseline pupil sizes. In line with data in the literature, the pupil centre was significantly decentred relative to the corneal centre in the nasal and superior direction. Pupil decentration changed significantly with pupil size by 0.05 mm on average for 1 mm of constriction. Assuming a Hirschberg ratio of 12° mm(-1) , a shift of 0.05 mm is equivalent to a measurement error in a Purkinje image-based eye tracker of 0.6°. However, the induced measurement error could also exceed 1.5° in some subjects for only a 1 mm change in pupil size. © 2013 The Authors Ophthalmic & Physiological Optics © 2013 The College of Optometrists.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Via, Riccardo, E-mail: riccardo.via@polimi.it; Fassi, Aurora; Fattori, Giovanni
Purpose: External beam radiotherapy currently represents an important therapeutic strategy for the treatment of intraocular tumors. Accurate target localization and efficient compensation of involuntary eye movements are crucial to avoid deviations in dose distribution with respect to the treatment plan. This paper describes an eye tracking system (ETS) based on noninvasive infrared video imaging. The system was designed for capturing the tridimensional (3D) ocular motion and provides an on-line estimation of intraocular lesions position based on a priori knowledge coming from volumetric imaging. Methods: Eye tracking is performed by localizing cornea and pupil centers on stereo images captured by twomore » calibrated video cameras, exploiting eye reflections produced by infrared illumination. Additionally, torsional eye movements are detected by template matching in the iris region of eye images. This information allows estimating the 3D position and orientation of the eye by means of an eye local reference system. By combining ETS measurements with volumetric imaging for treatment planning [computed tomography (CT) and magnetic resonance (MR)], one is able to map the position of the lesion to be treated in local eye coordinates, thus enabling real-time tumor referencing during treatment setup and irradiation. Experimental tests on an eye phantom and seven healthy subjects were performed to assess ETS tracking accuracy. Results: Measurements on phantom showed an overall median accuracy within 0.16 mm and 0.40° for translations and rotations, respectively. Torsional movements were affected by 0.28° median uncertainty. On healthy subjects, the gaze direction error ranged between 0.19° and 0.82° at a median working distance of 29 cm. The median processing time of the eye tracking algorithm was 18.60 ms, thus allowing eye monitoring up to 50 Hz. Conclusions: A noninvasive ETS prototype was designed to perform real-time target localization and eye movement monitoring during ocular radiotherapy treatments. The device aims at improving state-of-the-art invasive procedures based on surgical implantation of radiopaque clips and repeated acquisition of X-ray images, with expected positive effects on treatment quality and patient outcome.« less
Via, Riccardo; Fassi, Aurora; Fattori, Giovanni; Fontana, Giulia; Pella, Andrea; Tagaste, Barbara; Riboldi, Marco; Ciocca, Mario; Orecchia, Roberto; Baroni, Guido
2015-05-01
External beam radiotherapy currently represents an important therapeutic strategy for the treatment of intraocular tumors. Accurate target localization and efficient compensation of involuntary eye movements are crucial to avoid deviations in dose distribution with respect to the treatment plan. This paper describes an eye tracking system (ETS) based on noninvasive infrared video imaging. The system was designed for capturing the tridimensional (3D) ocular motion and provides an on-line estimation of intraocular lesions position based on a priori knowledge coming from volumetric imaging. Eye tracking is performed by localizing cornea and pupil centers on stereo images captured by two calibrated video cameras, exploiting eye reflections produced by infrared illumination. Additionally, torsional eye movements are detected by template matching in the iris region of eye images. This information allows estimating the 3D position and orientation of the eye by means of an eye local reference system. By combining ETS measurements with volumetric imaging for treatment planning [computed tomography (CT) and magnetic resonance (MR)], one is able to map the position of the lesion to be treated in local eye coordinates, thus enabling real-time tumor referencing during treatment setup and irradiation. Experimental tests on an eye phantom and seven healthy subjects were performed to assess ETS tracking accuracy. Measurements on phantom showed an overall median accuracy within 0.16 mm and 0.40° for translations and rotations, respectively. Torsional movements were affected by 0.28° median uncertainty. On healthy subjects, the gaze direction error ranged between 0.19° and 0.82° at a median working distance of 29 cm. The median processing time of the eye tracking algorithm was 18.60 ms, thus allowing eye monitoring up to 50 Hz. A noninvasive ETS prototype was designed to perform real-time target localization and eye movement monitoring during ocular radiotherapy treatments. The device aims at improving state-of-the-art invasive procedures based on surgical implantation of radiopaque clips and repeated acquisition of X-ray images, with expected positive effects on treatment quality and patient outcome.
Basarir, Berna; Celik, Ugur; Altan, Cigdem; Celik, Nimet Burcu
2018-02-01
To evaluate the choroidal thickness on acute anterior uveitis in patients with HLA-B27-positive ankylosing spondylitis. In this study, 32 eyes of 16 HLA-B27 positive AS patients with anterior uveitis and age-matched 19 eyes for control group were analyzed between January 2014 and April 2015. Assessment criteria were uveitis activity, visual acuity, flare existence, subfoveal choroidal thickness and central macular thickness measurements. The mean subfoveal choroidal thicknesses in affected eye group (Group 1), unaffected eye group (Group 2) and control group (Group 3) were 348.31 ± 72.7, 301.12 ± 49.2 and 318.0 ± 74.3, respectively, in active periods. (p = 0.04 between Group 1 and Group 2, p = 0.234 between Group 1 and Group 3) The mean central macular thicknesses of Group 1, Group 2 and Group 3 were 268.50 ± 16.5, 267.31 ± 16.3 and 249.7 ± 30.5, respectively, in active periods. (p = 0.84 between Group 1 and Group 2, p = 0.029 between Group 1 and Group 3). However, in convalescence period, the mean subfoveal choroidal thicknesses of Group 1, Group 2 and Group 3 were 322.40 ± 48.5, 300.75 ± 47.7 and 318.0 ± 74.3, respectively. (p = 0.22 between Group 1 and Group 2, p = 0.854 between Group 1 and Group 3) The mean central macular thicknesses of Group 1, Group 2 and Group 3 were 269.75 ± 21.9, 256.62 ± 21.5 and 249.7 ± 30.5, respectively. (p = 0.09 between Group 1 and Group 2, p = 0.03 between Group 1 and Group 3). In HLA-B27 positive ankylosing spondylitis patients with anterior uveitis, the choroidal thicknesses of the affected eyes were found as thicker than fellow unaffected one or control eyes in active period. The central macular thicknesses are not affected on both active and convalescent period.
Differences in intermittent postural control between normal-weight and obese children.
Villarrasa-Sapiña, Israel; García-Massó, Xavier; Serra-Añó, Pilar; Garcia-Lucerga, Consolación; Gonzalez, Luis-Millán; Lurbe, Empar
2016-09-01
The main objective of this study was to determine differences in postural control between obese and non-obese children. The study design was cross-sectional, prospective, between-subjects. Postural control variables were obtained from a group of obese children and a normal-weight control group under two different postural conditions: bipedal standing position with eyes open and bipedal standing with eyes closed. Variables were obtained for each balance condition using time domain and sway-density plot analysis of the center of pressure signals acquired by means of a force plate. Pairwise comparisons revealed significant differences between obese and normal-weight children in mean velocity in antero-posterior and medio-lateral directions, ellipse area and mean distance with both eyes open and eyes closed. Normal-weight subjects obtained lower values in all these variables than obese subjects. Furthermore, there were differences between both groups in mean peaks with eyes open and in mean time with eyes closed. Alterations were detected in the intermittent postural control in obese children. According to the results obtained, active anticipatory control produces higher center of pressure displacement responses in obese children and the periods during which balance is maintained by passive control and reflex mechanisms are of shorter duration. Copyright © 2016 Elsevier B.V. All rights reserved.
Central corneal thickness measurements and ultrasonographic study of the growing equine eye.
Herbig, Lena E; Eule, J Corinna
2015-11-01
The aim of this study was to determine the central corneal thickness (CCT) of healthy equine eyes with high-frequency ultrasound (HF) and ultrasound biomicroscopy (UBM) and to measure the axial dimensions with B-mode ultrasound. Additionally, the influence of the age on the measured dimensions of the globe was analyzed. Fifty warm blood horses (mean age 23.0 ± 21.12 months) were divided into 3 age groups (group 1: 0-6 months; group 2: ≥7-30 months; and group 3: ≥31-78 months). Corneal measurements were performed with a 22-MHz and a 50-MHz transducer. Crystalline lens thickness (CLT), vitreous chamber depth (VCD), and axial globe length (AGL) were measured at a frequency of 10 MHz. Anterior chamber depth (ACD) was calculated. The eyes were measured under general anesthesia nonrelated to this study. The mean CCT of 50 eyes was 818 ± 41 μm. The mean values ± SD in mm for axial dimensions were AGL 34.7 ± 2.7, ACD 3.4 ± 0.7, CLT 10.0 ± 0.9, and VCD of 20.4 ± 1.5. A positive correlation with increasing age was found for all dimensions. No significant differences were found between the gender and the left or right eye. HF and UBM are valuable high-resolution imaging tools for CCT measurements in horses. The here-obtained values support previous findings that a positive correlation with increasing age exists for CCT, ACD, CLT, VCD, and AGL in horse. © 2015 American College of Veterinary Ophthalmologists.
Gandolfi, Stefano A; Ungaro, Nicola; Tardini, Maria Grazia; Ghirardini, Stella; Carta, Arturo; Mora, Paolo
2014-12-01
Prospective long-term analyses of the role of drug-induced mydriasis and laser peripheral iridotomy (LPI) are needed to identify and manage the eyes of patients with pigment dispersion syndrome (PDS) at risk for progressing to ocular hypertension. To assess the 10-year incidence of increased intraocular pressure (IOP) in the 2 eyes of patients with PDS, with 1 eye that underwent LPI and the other that did not. In a randomized clinical trial in the glaucoma research unit at the University Hospital of Parma, Italy, 72 patients with PDS underwent phenylephrine testing. Of these 72 patients, 29 (58 eyes) tested positive for succeeding IOP elevation, and 43 (59 eyes) tested negative. For the 29 high-risk patients (all in both eyes), one eye was randomly assigned to LPI, and the fellow eye was left untreated. For the 43 low-risk patients, the affected eyes were left untreated. An IOP elevation of 5 mm Hg or higher vs baseline (daily phasing) was considered to be a significant increase (ie, an event). In the high-risk group, 3 of 21 eyes that underwent LPI (14.3%) and 13 of 21 untreated eyes (61.9%) showed an increase in IOP of 5 mm Hg or higher during the follow-up period; 4 of 35 low-risk eyes (11.4%) showed a similar increase. Event-free mean (SD) time was 7.99 (0.43) years for high-risk treated eyes, 3.89 (0.68) years for high-risk untreated eyes, and 7.16 (0.23) years for low-risk eyes. The log-rank test showed the following: P < .001 for treated high-risk eyes vs untreated high-risk eyes, P = .74 for treated high-risk eyes vs low-risk eyes, and P < .001 for untreated high-risk eyes vs low-risk eyes. At the end of the 10-year follow-up, (1) approximately one-third of the whole PDS patient population showed an IOP increase of 5 mm Hg or higher in at least 1 eye; (2) phenylephrine testing identified eyes at high risk for developing IOP elevation; and (3) LPI, when performed on high-risk eyes, reduced the rate of IOP elevation to the same level as the low-risk eyes. clinicaltrials.gov Identifier: NCT01053416.
The effect of UV-blocking contact lenses as a therapy for canine chronic superficial keratitis.
Denk, Nora; Fritsche, Jens; Reese, Sven
2011-05-01
To evaluate the effect of UV-blocking soft contact lenses in treatment for chronic superficial keratitus (CSK). Twenty six dogs with CSK were treated continuously with UV-blocking contact lenses for 6 months. A contact lens was placed on one eye of each dog; the other eye remained without a lens as a control eye. After this primary study, five of the dogs were further treated and they wore then contact lenses in both eyes. Continuously, all patients were concurrently treated topically with cyclosporine. The contact lenses were changed every 4 weeks and an ophthalmic examination performed. Evaluation criteria included corneal alterations as pigmentation, edema, pannus and vascularization. To determine the transmittance characteristics of the contact lenses before and after use, 32 contact lenses were measured with a UV-vis-NIR spectrophotometer. Pigmentation increased in eyes wearing lenses and in control eyes over the evaluation period of 6 months. Corneal edema increased in the eyes wearing lenses, but remained unaffected in the control eyes. A significant difference in the incidence of pannus and the extent of corneal vascularisation could not be evaluated. Adverse effects were noted in six cases (corneal edema and vascularisation, conjunctivitis, blepharospasm). All new lenses studied reduced UV-radiation to a safe level, whereas used lenses did not maintain their transmittance characteristics. No positive effect of UV-blocking contact lenses could be proven with the study design used. © 2011 American College of Veterinary Ophthalmologists.
Kohnen, T; Kühne, C; Cichocki, M; Strenger, A
2007-01-01
Centration of the ablation zone decisively influences the result of wavefront-guided LASIK. Cyclorotation of the eye occurs as the patient changes from the sitting position during aberrometry to the supine position during laser surgery and may lead to induction of lower and higher order aberrations. Twenty patients (40 eyes) underwent wavefront-guided LASIK (B&L 217z 100 excimer laser) with a static eyetracker driven by iris recognition (mean preoperative SE: -4.72+/-1.45 D; range: -1.63 to -7.00 D). The iris patterns of the patients' eyes were memorized during aberrometry and after flap creation. The mean absolute value of the measured cyclorotation was -1.5+/-4.2 degrees (range: -11.0 to 6.9 degrees ). The mean cyclorotation was 3.5+/-2.7 masculine (range: 0.1 to 11.0 degrees ). In 65% of all eyes cyclorotation was >2 masculine. A static eyetracker driven by iris recognition demonstrated that cyclorotation of up to 11 degrees may occur in myopic and myopic astigmatic eyes when changing from a sitting to a supine position. Use of static eyetrackers with iris recognition may provide a more precise positioning of the ablation profile as they detect and compensate cyclorotation.
NASA Technical Reports Server (NTRS)
Crawford, Daniel J.; Burdette, Daniel W.; Capron, William R.
1993-01-01
The methodology and techniques used to collect and analyze look-point position data from a real-time ATC display-format comparison experiment are documented. That study compared the delivery precision and controller workload of three final approach spacing aid display formats. Using an oculometer, controller lookpoint position data were collected, associated with gaze objects (e.g., moving aircraft) on the ATC display, and analyzed to determine eye-scan behavior. The equipment involved and algorithms for saving, synchronizing with the ATC simulation output, and filtering the data are described. Target (gaze object) and cross-check scanning identification algorithms are also presented. Data tables are provided of total dwell times, average dwell times, and cross-check scans. Flow charts, block diagrams, file record descriptors, and source code are included. The techniques and data presented are intended to benefit researchers in other studies that incorporate non-stationary gaze objects and oculometer equipment.
The Importance of Postural Cues for Determining Eye Height in Immersive Virtual Reality
Leyrer, Markus; Linkenauger, Sally A.; Bülthoff, Heinrich H.; Mohler, Betty J.
2015-01-01
In human perception, the ability to determine eye height is essential, because eye height is used to scale heights of objects, velocities, affordances and distances, all of which allow for successful environmental interaction. It is well understood that eye height is fundamental to determine many of these percepts. Yet, how eye height itself is provided is still largely unknown. While the information potentially specifying eye height in the real world is naturally coincident in an environment with a regular ground surface, these sources of information can be easily divergent in similar and common virtual reality scenarios. Thus, we conducted virtual reality experiments where we manipulated the virtual eye height in a distance perception task to investigate how eye height might be determined in such a scenario. We found that humans rely more on their postural cues for determining their eye height if there is a conflict between visual and postural information and little opportunity for perceptual-motor calibration is provided. This is demonstrated by the predictable variations in their distance estimates. Our results suggest that the eye height in such circumstances is informed by postural cues when estimating egocentric distances in virtual reality and consequently, does not depend on an internalized value for eye height. PMID:25993274
The importance of postural cues for determining eye height in immersive virtual reality.
Leyrer, Markus; Linkenauger, Sally A; Bülthoff, Heinrich H; Mohler, Betty J
2015-01-01
In human perception, the ability to determine eye height is essential, because eye height is used to scale heights of objects, velocities, affordances and distances, all of which allow for successful environmental interaction. It is well understood that eye height is fundamental to determine many of these percepts. Yet, how eye height itself is provided is still largely unknown. While the information potentially specifying eye height in the real world is naturally coincident in an environment with a regular ground surface, these sources of information can be easily divergent in similar and common virtual reality scenarios. Thus, we conducted virtual reality experiments where we manipulated the virtual eye height in a distance perception task to investigate how eye height might be determined in such a scenario. We found that humans rely more on their postural cues for determining their eye height if there is a conflict between visual and postural information and little opportunity for perceptual-motor calibration is provided. This is demonstrated by the predictable variations in their distance estimates. Our results suggest that the eye height in such circumstances is informed by postural cues when estimating egocentric distances in virtual reality and consequently, does not depend on an internalized value for eye height.
A MATLAB-based eye tracking control system using non-invasive helmet head restraint in the macaque.
De Luna, Paolo; Mohamed Mustafar, Mohamed Faiz Bin; Rainer, Gregor
2014-09-30
Tracking eye position is vital for behavioral and neurophysiological investigations in systems and cognitive neuroscience. Infrared camera systems which are now available can be used for eye tracking without the need to surgically implant magnetic search coils. These systems are generally employed using rigid head fixation in monkeys, which maintains the eye in a constant position and facilitates eye tracking. We investigate the use of non-rigid head fixation using a helmet that constrains only general head orientation and allows some freedom of movement. We present a MATLAB software solution to gather and process eye position data, present visual stimuli, interact with various devices, provide experimenter feedback and store data for offline analysis. Our software solution achieves excellent timing performance due to the use of data streaming, instead of the traditionally employed data storage mode for processing analog eye position data. We present behavioral data from two monkeys, demonstrating that adequate performance levels can be achieved on a simple fixation paradigm and show how performance depends on parameters such as fixation window size. Our findings suggest that non-rigid head restraint can be employed for behavioral training and testing on a variety of gaze-dependent visual paradigms, reducing the need for rigid head restraint systems for some applications. While developed for macaque monkey, our system of course can work equally well for applications in human eye tracking where head constraint is undesirable. Copyright © 2014. Published by Elsevier B.V.
Contrast adaptation induced by defocus - a possible error signal for emmetropization?
Ohlendorf, Arne; Schaeffel, Frank
2009-01-01
To describe some features of contrast adaptation as induced by imposed positive or negative defocus. To study its time course and selectivity for the sign of the imposed defocus. Contrast adaptation, CA (here referred to as any change in supra-threshold contrast sensitivity) was induced by presenting a movie to the subjects on a computer screen at 1m distance for 10min, while the right eye was defocused by a trial lens (+4D (n=25); -4D (n=10); -2D (n=11 subjects). The PowerRefractor was used to track accommodation binocularly. Contrast sensitivity at threshold was measured by a method of adjustment with a Gabor patch of 1deg angular subtense, filled with 3.22cyc/deg sine wave grating presented on a computer screen at 1m distance on gray background (33cd/m(2)). Supra-threshold contrast sensitivity was quantified by an interocular contrast matching task, in which the subject had to match the contrast of the sine wave grating seen with the right eye with the contrast of a grating with fixed contrast of 0.1. (1) Contrast sensitivity thresholds were not lowered by previous viewing of defocused movies. (2) By wearing positive lenses, the supra-threshold contrast sensitivity in the right eye was raised by about 30% and remained elevated for at least 2min until baseline was reached after about 5min. (3) CA was induced only by positive, but not by negative lenses, even after the distance of the computer screen was taken into account (1m, equivalent to +1D). In five subjects, binocular accommodation was tracked over the full adaptation period. Accommodation appeared to focus the eye not wearing a lens, but short transient switches in focus to the lens wearing eye could not be entirely excluded. Transient contrast adaptation was found at 3.22cyc/deg when positive lenses were worn but not with negative lenses. This asymmetry is intriguing. While it may represent an epiphenomenon of physiological optics, further experiments are necessary to determine whether it could also trace back to differences in CA with defocus of different sign.
Kumar, Dhivya Ashok; Agarwal, Amar; Agarwal, Athiya; Chandrasekar, Radika; Priyanka, Vijetha
2015-01-01
Long-term assessment of the optic position of glued transscleral fixated intraocular lens (IOL) with optical coherence tomography (OCT). Prospective observational case series. Patients with a minimum 5 years' follow-up after glued IOL surgery were included. Postoperatively, IOL position was examined by anterior segment OCT (Carl Zeiss Meditec) and the scans were analyzed in 2 axes (180°-0° and 270°-90°) using MatLab (Mathworks). Best-corrected visual acuity (BCVA; Snellen's charts), Orbscan, retinoscopy, refraction, and slit-lamp biomicroscopy were performed. The distance between the iris margin and the anterior IOL optic (D1, D2), slope of the line across the iris and IOL, the slope ratio between the IOL and iris, IOL tilt, and optic surface changes were determined and correlated with the astigmatism and vision. A total of 60 eyes (mean follow-up of 5.9±0.2 years; range, 5-6 years) were evaluated. There was a significant correlation (P = 0.000) between the slope of iris and the IOL in horizontal and vertical axes. The mean D1 and D2 were 0.94 ± 0.36 and 0.95 ± 0.36 mm, respectively. Nine of 60 eyes (15%) had pigment dispersed on the IOL surface. Twenty-one eyes (35%) had optic tilt detected on OCT and 65% of eyes had no optic tilt. The mean angle between the IOL and the iris was noted to be 3.2 ± 2.7° and 2.9 ± 2.6° in horizontal and vertical axes, respectively. The mean ocular residual astigmatism (ORA) was 0.53 ± 0.5 diopters. There was no difference in the ORA between the eyes with and without tilt (P = 0.762). There was no correlation (P = 0.348) between the ORA and BCVA. Position of the IOL was not dependent on the type of lens, age of the patient, or the preoperative surgical indication. Long-term analysis with OCT demonstrated good IOL positioning without any significant optic tilt in patients with glued IOL fixation. Copyright © 2015 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Chen, Henry Shen-Lih; Liu, Chun-Hsiu; Lu, Da-Wen
2016-01-01
Background/Purpose: To evaluate and compare the diagnostic discriminative ability for detecting glaucoma in highly myopic eyes from a normative database of macular ganglion cell complex (mGCC) thickness based on nonhighly myopic and highly myopic normal eyes. Methods: Forty-nine eyes of 49 participants with high myopia (axial length ≥ 26.0 mm) were enrolled. Spectral-domain optical coherence tomography scans were done using RS-3000, and the mGCC thickness/significance maps within a 9-mm diameter circle were generated using built-in software. We compared the difference of sensitivity, specificity, and diagnostic accuracy between the nonhighly myopic database and the highly myopic database for differentiating the early glaucomatous eyes from the nonglaucomatous eyes. Results: This study enrolled 15 normal eyes and 34 eyes with glaucoma. The mean mGCC thickness of the glaucoma group was significantly less than that of the normal group (p < 0.001). Sensitivity was 96.3%, and the specificity was 50.0% when using the nonhighly myopic normative database. When the highly myopic normative database was used, the sensitivity was 88.9%, and the specificity was 90.0%. The false positive rate was significantly lower when using the highly myopic normative database (p < 0.05). Conclusion: The evaluations of glaucoma in eyes with high myopia using a nonhighly myopic normative database may lead to a frequent misdiagnosis. When evaluating glaucoma in high myopic eyes, the mGCC thickness determined by the long axial length high myopic normative database should be applied. PMID:29018704
Yazdani, Shahin; Akbarian, Shadi; Pakravan, Mohammad; Doozandeh, Azadeh; Afrouzifar, Mohsen
2015-03-01
To compare ocular biometric parameters using low-coherence interferometry among siblings affected with different degrees of primary angle closure (PAC). In this cross-sectional comparative study, a total of 170 eyes of 86 siblings from 47 families underwent low-coherence interferometry (LenStar 900; Haag-Streit, Koeniz, Switzerland) to determine central corneal thickness, anterior chamber depth (ACD), aqueous depth (AD), lens thickness (LT), vitreous depth, and axial length (AL). Regression coefficients were applied to show the trend of the measured variables in different stages of angle closure. To evaluate the discriminative power of the parameters, receiver operating characteristic curves were used. Best cutoff points were selected based on the Youden index. Sensitivity, specificity, positive and negative predicative values, positive and negative likelihood ratios, and diagnostic accuracy were determined for each variable. All biometric parameters changed significantly from normal eyes to PAC suspects, PAC, and PAC glaucoma; there was a significant stepwise decrease in central corneal thickness, ACD, AD, vitreous depth, and AL, and an increase in LT and LT/AL. Anterior chamber depth and AD had the best diagnostic power for detecting angle closure; best levels of sensitivity and specificity were obtained with cutoff values of 3.11 mm for ACD and 2.57 mm for AD. Biometric parameters measured by low-coherence interferometry demonstrated a significant and stepwise change among eyes affected with various degrees of angle closure. Although the current classification scheme for angle closure is based on anatomical features, it has excellent correlation with biometric parameters.
Possibilities and Implications of Using a Motion-Tracking System in Physical Education
ERIC Educational Resources Information Center
Chow, Jia Yi; Tan, Clara Wee Keat; Lee, Miriam Chang Yi; Button, Chris
2014-01-01
Advances in technology have created new opportunities for enhanced delivery of teaching to improve the acquisition of game skills in physical education (PE). The availability of a motion-tracking system (i.e. the A-Eye), which determines positional information of students in a practice context, might offer a suitable technology to support…
Medici, S; Pitzschke, A; Cherbuin, N; Boldini, M; Sans-Merce, M; Damet, J
2017-11-01
The purpose of this work was to estimate the eye lens radiation exposure of the medical staff during interventional urology procedures. The measurements were carried out for six medical staff members performing 33 fluoroscopically-guided procedures. All procedures were performed with the X-ray tube positioned over the couch. The dose equivalents (H p (0.07)) were measured at the eye level using optically stimulated luminescent (OSL) dosimeters and at the chest level with OSL dosimeters placed over the protective apron. The ratio of the dose measured close to the eye lens and on the chest was determined. The annual eye lens dose was estimated based on the workload in the service. For the physician and the instrumentalist nurse, the eye to chest dose ratios were 0.9±0.4 and 2.6±1.6 (k = 2), respectively. The average doses per procedure received by the eye lens were 78±24 μSv and 38±18 μSv, respectively. The eye lens dose per DAP was 8.4±17.5 μSv/(Gy·cm 2 ) for the physician and 4.1±8.7 μSv/(Gy·cm 2 ) for the instrumentalist nurse. The results indicate that the eye lens to chest dose ratio greatly varies according to the staff function and that the dose equivalent measured by the personal dosimeter worn on the chest may underestimate the eye lens dose of some medical staff members. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Bueeler, Michael; Mrochen, Michael
2005-01-01
The aim of this theoretical work was to investigate the robustness of scanning spot laser treatments with different laser spot diameters and peak ablation depths in case of incomplete compensation of eye movements due to eye-tracker latency. Scanning spot corrections of 3rd to 5th Zernike order wavefront errors were numerically simulated. Measured eye-movement data were used to calculate the positioning error of each laser shot assuming eye-tracker latencies of 0, 5, 30, and 100 ms, and for the case of no eye tracking. The single spot ablation depth ranged from 0.25 to 1.0 microm and the spot diameter from 250 to 1000 microm. The quality of the ablation was rated by the postoperative surface variance and the Strehl intensity ratio, which was calculated after a low-pass filter was applied to simulate epithelial surface smoothing. Treatments performed with nearly ideal eye tracking (latency approximately 0) provide the best results with a small laser spot (0.25 mm) and a small ablation depth (250 microm). However, combinations of a large spot diameter (1000 microm) and a small ablation depth per pulse (0.25 microm) yield the better results for latencies above a certain threshold to be determined specifically. Treatments performed with tracker latencies in the order of 100 ms yield similar results as treatments done completely without eye-movement compensation. CONCWSIONS: Reduction of spot diameter was shown to make the correction more susceptible to eye movement induced error. A smaller spot size is only beneficial when eye movement is neutralized with a tracking system with a latency <5 ms.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-13
...] Determination That REV-EYES (Dapiprazole Hydrochloride Ophthalmic Solution), 0.5%, Was Not Withdrawn From Sale.... SUMMARY: The Food and Drug Administration (FDA) has determined that REV-EYES (dapiprazole hydrochloride... CFR 314.161)). FDA may not approve an ANDA that does not refer to a listed drug. REV-EYES (dapiprazole...
NASA Technical Reports Server (NTRS)
Angelaki, D. E.; Hess, B. J.
1996-01-01
1. The dynamic properties of otolith-ocular reflexes elicited by sinusoidal linear acceleration along the three cardinal head axes were studied during off-vertical axis rotations in rhesus monkeys. As the head rotates in space at constant velocity about an off-vertical axis, otolith-ocular reflexes are elicited in response to the sinusoidally varying linear acceleration (gravity) components along the interaural, nasooccipital, or vertical head axis. Because the frequency of these sinusoidal stimuli is proportional to the velocity of rotation, rotation at low and moderately fast speeds allows the study of the mid-and low-frequency dynamics of these otolith-ocular reflexes. 2. Animals were rotated in complete darkness in the yaw, pitch, and roll planes at velocities ranging between 7.4 and 184 degrees/s. Accordingly, otolith-ocular reflexes (manifested as sinusoidal modulations in eye position and/or slow-phase eye velocity) were quantitatively studied for stimulus frequencies ranging between 0.02 and 0.51 Hz. During yaw and roll rotation, torsional, vertical, and horizontal slow-phase eye velocity was sinusoidally modulated as a function of head position. The amplitudes of these responses were symmetric for rotations in opposite directions. In contrast, mainly vertical slow-phase eye velocity was modulated during pitch rotation. This modulation was asymmetric for rotations in opposite direction. 3. Each of these response components in a given rotation plane could be associated with an otolith-ocular response vector whose sensitivity, temporal phase, and spatial orientation were estimated on the basis of the amplitude and phase of sinusoidal modulations during both directions of rotation. Based on this analysis, which was performed either for slow-phase eye velocity alone or for total eye excursion (including both slow and fast eye movements), two distinct response patterns were observed: 1) response vectors with pronounced dynamics and spatial/temporal properties that could be characterized as the low-frequency range of "translational" otolith-ocular reflexes; and 2) response vectors associated with an eye position modulation in phase with head position ("tilt" otolith-ocular reflexes). 4. The responses associated with two otolith-ocular vectors with pronounced dynamics consisted of horizontal eye movements evoked as a function of gravity along the interaural axis and vertical eye movements elicited as a function of gravity along the vertical head axis. Both responses were characterized by a slow-phase eye velocity sensitivity that increased three- to five-fold and large phase changes of approximately 100-180 degrees between 0.02 and 0.51 Hz. These dynamic properties could suggest nontraditional temporal processing in utriculoocular and sacculoocular pathways, possibly involving spatiotemporal otolith-ocular interactions. 5. The two otolith-ocular vectors associated with eye position responses in phase with head position (tilt otolith-ocular reflexes) consisted of torsional eye movements in response to gravity along the interaural axis, and vertical eye movements in response to gravity along the nasooccipital head axis. These otolith-ocular responses did not result from an otolithic effect on slow eye movements alone. Particularly at high frequencies (i.e., high speed rotations), saccades were responsible for most of the modulation of torsional and vertical eye position, which was relatively large (on average +/- 8-10 degrees/g) and remained independent of frequency. Such reflex dynamics can be simulated by a direct coupling of primary otolith afferent inputs to the oculomotor plant. (ABSTRACT TRUNCATED).
Hypothesized eye movements of neurolinguistic programming: a statistical artifact.
Farmer, A; Rooney, R; Cunningham, J R
1985-12-01
Neurolinguistic programming's hypothesized eye-movements were measured independently from videotapes of 30 subjects, aged 15 to 76 yr., who were asked to recall visual pictures, recorded audio sounds, and textural objects. chi 2 indicated that subjects' responses were significantly different from those predicted. When chi 2 comparisons were weighted by number of eye positions assigned to each modality (3 visual, 3 auditory, 1 kinesthetic), subjects' responses did not differ significantly from the expected pattern. These data indicate that the eye-movement hypothesis may represent randomly occurring rather than sensory-modality-related positions.
Design of liposomal colloidal systems for ocular delivery of ciprofloxacin
Taha, Ehab I.; El-Anazi, Magda H.; El-Bagory, Ibrahim M.; Bayomi, Mohsen A.
2013-01-01
Ophthalmic drug bioavailability is limited due to protective mechanisms of the eye which require the design of a system to enhance ocular delivery. In this study several liposomal formulations containing ciprofloxacin (CPX) have been formulated using reverse phase evaporation technique with final dispersion of pH 7.4. Different types of phospholipids including Phosphatidylcholine, Dipalmitoylphosphatidylcholine and Dimyristoyl-sn-glycero-3-phosphocholine were utilized. The effect of formulation factors such as type of phospholipid, cholesterol content, incorporation of positively charging inducing agents and ultrasonication on the properties of the liposomal vesicles was studied. Bioavailability of selected liposomal formulations in rabbit eye aqueous humor has been investigated and compared with that of commercially available CPX eye drops (Ciprocin®). Pharmacokinetic parameters including Cmax, Tmax, elimination rate constant, t1/2, MRT and AUC0–∞, were determined. The investigated formulations showed more than three folds of improvement in CPX ocular bioavailability compared with the commercial product. PMID:25061409
Eye Size and Set in Small-Bodied Fossil Primates: A Three-Dimensional Method.
Rosenberger, Alfred L; Smith, Tim D; DeLeon, Valerie B; Burrows, Anne M; Schenck, Robert; Halenar, Lauren B
2016-12-01
We introduce a new method to geometrically reconstruct eye volume and placement in small-bodied primates based on the three-dimensional contour of the intraorbital surface. We validate it using seven species of living primates, with dry skulls and wet dissections, and test its application on seven species of Paleogene fossils of interest. The method performs well even when the orbit is damaged and incomplete, lacking the postorbital bar and represented only by the orbital floor. Eye volume is an important quantity for anatomic and metabolic reasons, which due to differences in eye set, or position within (or outside) the bony orbit, can be underestimated in living and fossil forms when calculated from aperture diameter. Our Ectopic Index quantifies how much the globe's volume protrudes anteriorly from the aperture. Lemur, Notharctus and Rooneyia resemble anthropoids, with deeply recessed eyes protruding 11%-13%. Galago and Tarsius are the other extreme, at 47%-56%. We argue that a laterally oriented aperture has little to do with line-of-sight in euprimates, as large ectopic eyes can position the cornea to enable a directly forward viewing axis, and soft tissue positions the eyes facing forward in megachiropteran bats, which have unenclosed, open eye sockets. The size and set of virtual eyes reconstructed from 3D cranial models confirm that eyes were large to hypertrophic in Hemiacodon, Necrolemur, Microchoerus, Pseudoloris and Shoshonius, but eye size in Rooneyia may have been underestimated by measuring the aperture, as in Aotus. Anat Rec, 299:1671-1689, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
The Effect of the Crystalline Lens on Central Vault After Implantable Collamer Lens Implantation.
Qi, Meng-Ying; Chen, Qian; Zeng, Qing-Yan
2017-08-01
To identify associations between crystalline lens-related factors and central vault after Implantable Collamer Lens (ICL) (Staar Surgical, Monrovia, CA) implantation. This retrospective clinical study included 320 eyes from 186 patients who underwent ICL implantation surgery. At 1 year after surgery, the central vault was measured using anterior segment optical coherence tomography. Preoperative anterior chamber depth, lens thickness, lens position (lens position = anterior chamber depth + 1/2 lens thickness), and vault were analyzed to investigate the effects of lens-related factors on postoperative vault. The mean vault was 513 ± 215 µm at 1 year after surgery. Vault was positively correlated with preoperative anterior chamber depth (r = 0.495, P < .001) and lens position (r = 0.371, P < .001), but negatively correlated with lens thickness (r = -0.262, P < .001). Eyes with vaults of less than 250 µm had shallower anterior chambers, thicker lenses, and smaller lens position than eyes in the other two vault groups (which had vaults ≥ 250 µm) (P < .001). Eyes with both anterior chamber depth less than 3.1 mm and lens position less than 5.1 mm had greatly reduced vaults (P < .001). The crystalline lens could have an important influence on postoperative vault. Eyes with a shallower anterior chamber and a forward lens position will have lower vaults. [J Refract Surg. 2017;33(8):519-523.]. Copyright 2017, SLACK Incorporated.
Symmetry of oculomotor burst neuron coordinates about Listing's plane.
Crawford, J D; Vilis, T
1992-08-01
1. The purpose of this investigation was to determine the axes of eye rotation generated by oculomotor burst neuron populations and the coordinate system that they collectively define. In particular, we asked if such coordinates might be related to constraints in the emergent behavior, i.e., Listing's law for saccades. 2. The mesencephalic rostral interstitial nucleus of the medial longitudinal fasciculus (riMLF) was identified in four monkeys with the use of single-unit recording, and then explored with the use of electrical microstimulation and pharmacological inactivation with the inhibitory gamma-aminobutyric acid (GABA) agonist muscimol. Three-dimensional (3-D) eye positions and velocities were recorded in one or both eyes while alert animals made eye movements in response to visual stimuli and head rotation. 3. Unilateral stimulation of the riMLF (20 microA, 200 Hz, 300-600 ms) produced conjugate, constant velocity eye rotations, which then stopped abruptly and held their final positions. This is expected if the riMLF produces phasic signals upstream from the oculomotor integrator. 4. Units that burst before upward or downward saccades were recorded intermingled in each side of the riMLF. Unilateral stimulation of the same riMLF sites produced eye rotations about primarily torsional axes, clockwise (CW) during right riMLF stimulation and counterclockwise (CCW) during left stimulation. Only small and inconsistent vertical components were observed, supporting the view that the riMLF carries intermingled up and down signals. 5. The torsional axes of eye rotation produced by riMLF stimulation did not correlate to external anatomic landmarks. Instead, stimulation axes from both riMLF sides aligned with the primary gaze direction orthogonal to Listing's plane of eye positions recorded during saccades. 6. Injection of muscimol into one side of the riMLF produced a conjugate deficit in saccades and quick phases, including a 50% reduction in all vertical velocities and complete loss of one torsional direction. CW was lost after right riMLF inactivation, and CCW was lost after left inactivation. 7. The plane that separated the intact torsional axes from the missing axes correlated with the orientation of Listing's plane. Thus, during left or right riMLF inactivation, the vertical axes of intact horizontal saccades were abnormally aligned with Listing's plane. The orientation of these axes was not correlated with external anatomic landmarks. 8. As suggested by their alignment with Listing's plane, the intact vertical axes of horizontal saccades following riMLF inactivation were orthogonal to torsional riMLF stimulation axes.(ABSTRACT TRUNCATED AT 400 WORDS)
Principi, Sara; Ginjaume, Mercè; Duch, Maria Amor; Sánchez, Roberto M; Fernández, Jose M; Vano, Eliseo
2015-04-01
The equivalent dose limit for the eye lens for occupational exposure recommended by the ICRP has been reduced to 20 mSv y(-1) averaged over defined periods of 5 y, with no single year exceeding 50 mSv. The compliance with this new requirement could not be easy in some workplace such as interventional radiology and cardiology. The aim of this study is to evaluate different possible approaches in order to have a good estimate of the eye lens dose during interventional procedures. Measurements were performed with an X-ray system Philips Allura FD-10, using a PMMA phantom to simulate the patient scattered radiation and a Rando phantom to simulate the cardiologist. Thermoluminescence (TL) whole-body and TL eye lens dosemeters together with Philips DoseAware active dosemeters were located on different positions of the Rando phantom to estimate the eye lens dose in typical cardiology procedures. The results show that, for the studied conditions, any of the analysed dosemeter positions are suitable for eye lens dose assessment. However, the centre of the thyroid collar and the left ear position provide a better estimate. Furthermore, in practice, improper use of the ceiling-suspended screen can produce partial protection of some parts of the body, and thus large differences between the measured doses and the actual exposure of the eye could arise if the dosemeter is not situated close to the eye. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Retinal Thickening and Photoreceptor Loss in HIV Eyes without Retinitis.
Arcinue, Cheryl A; Bartsch, Dirk-Uwe; El-Emam, Sharif Y; Ma, Feiyan; Doede, Aubrey; Sharpsten, Lucie; Gomez, Maria Laura; Freeman, William R
2015-01-01
To determine the presence of structural changes in HIV retinae (i.e., photoreceptor density and retinal thickness in the macula) compared with age-matched HIV-negative controls. Cohort of patients with known HIV under CART (combination Antiretroviral Therapy) treatment were examined with a flood-illuminated retinal AO camera to assess the cone photoreceptor mosaic and spectral-domain optical coherence tomography (SD-OCT) to assess retinal layers and retinal thickness. Twenty-four eyes of 12 patients (n = 6 HIV-positive and 6 HIV-negative) were imaged with the adaptive optics camera. In each of the regions of interest studied (nasal, temporal, superior, inferior), the HIV group had significantly less mean cone photoreceptor density compared with age-matched controls (difference range, 4,308-6,872 cones/mm2). A different subset of forty eyes of 20 patients (n = 10 HIV-positive and 10 HIV-negative) was included in the retinal thickness measurements and retinal layer segmentation with the SD-OCT. We observed significant thickening in HIV positive eyes in the total retinal thickness at the foveal center, and in each of the three horizontal B-scans (through the macular center, superior, and inferior to the fovea). We also noted that the inner retina (combined thickness from ILM through RNFL to GCL layer) was also significantly thickened in all the different locations scanned compared with HIV-negative controls. Our present study shows that the cone photoreceptor density is significantly reduced in HIV retinae compared with age-matched controls. HIV retinae also have increased macular retinal thickness that may be caused by inner retinal edema secondary to retinovascular disease in HIV. The interaction of photoreceptors with the aging RPE, as well as possible low-grade ocular inflammation causing diffuse inner retinal edema, may be the key to the progressive vision changes in HIV-positive patients without overt retinitis.
Pharmacologic treatments for dry eye: a worthwhile investment?
Novack, Gary D
2002-01-01
To determine whether investment in a novel pharmacologic agent for the treatment of dry eye would be worthwhile from a financial perspective. Estimates were made of the cost and time required to develop a novel pharmacologic treatment of dry eye and the potential revenues for the product. These estimates were used to compute the value of the investment, adjusting for the time value of money. Development was estimated to cost $42 million and to take 55 months from investigational new drug exemption filing to new drug application approval. The potential market for this treatment was estimated at $542 million per year at year 5. Adding in the cost of development and marketing as well as other costs, net present value was very positive at the 5, 8, 10, and 40% cost of financing. The internal rate of return was 90%. In summary, if there were a successful pharmacologic treatment of dry eye and if a firm could manage the cash flow during the development, then the market potential approaches that of other treatment of chronic ophthalmic conditions (e.g., glaucoma), and it would be a worthwhile investment.
Mosaic: a position-effect variegation eye-color mutant in the mosquito Anopheles gambiae.
Benedict, M Q; McNitt, L M; Cornel, A J; Collins, F H
2000-01-01
The Mosaic (Mos) mutation, isolated in the F1 of 60Co-irradiated mosquitoes, confers variegated eye color to third and fourth instar larvae, pupae, and adults of the mosquito Anopheles gambiae. Mos is recessive in wild pink eye (p+) individuals, but is dominant and confers areas of wild-type pigment in mutant pink eye backgrounds. Mos is located 14.4 cM from pink eye on the X chromosome and is associated with a duplication of division 2B euchromatin that has been inserted into division 6 heterochromatin. Various combinations of Mos, pink eye alleles, and the autosomal mutation red eye were produced. In all cases, the darker pigmented regions of the eye in Mos individuals show the phenotypic interactions expected if the phenotype of those regions is due to expression of a p+ allele. Expression of Mos is suppressed by rearing larvae at 32 degrees C relative to 22 degrees C. All of these characteristics are consistent with Mos being a duplicated wild copy of the pink eye gene undergoing position-effect variegation.
Correlation between refraction level and retinal breaks in myopic eye.
Alimanović-Halilović, Emina
2008-11-01
In this study we analyzed 180 myopic eyes in order to determine the refraction that is "critical" for the occurrence of retinal breaks as a main cause of retinal detachment. Detachment of retina involves separation of the neurosensory retina from the pigmented epithelium with the severe impairment of vision. After the focused ophthalmological assessment, determination of objective refraction, indirect binocular ophthalmoscopy, we compared the diagnosed retinal breaks according to the shape with the refraction. All the examined eyes were divided into six groups according to the axis length. Mean age of our patients was between 48,43 and 51,60 years with SD ranging from 13,88 to 18,45. The age differences among the groups were not statistically significant. This study included 102 (56,7%) male and 78 (43,3%) female patients and no statistically significant differences between genders was found regarding the occurrence of retinal breaks compared to refraction. The most dominant ruptures were the round ones (28,2%), followed by oval (25%), the category of multiple small holes (19,2%), horseshoe shaped (15,3%), and finally holes with operculum. In cases with myopic refraction ranging between 3,50 and 7,49 dsph, the frequency of retinal breaks statistically significantly differs from all other analyzed refractions. Also, there is positive correlation between the above mentioned myopic refraction and the frequency of retinal breaks. In order to prevent retinal detachment in a myopic eye, we suggest further thorough examinations of the eye fundus in patients with the above mentioned myopia. Diagnosing retinal breaks involves the application of adequate therapy: laser photocoagulation, cryotherapy, sclera buckling and pneumatic retinopexy.
Prevalence of dry eye syndrome in an adult population.
Hashemi, Hassan; Khabazkhoob, Mehdi; Kheirkhah, Ahmad; Emamian, Mohammad Hassan; Mehravaran, Shiva; Shariati, Mohammad; Fotouhi, Akbar
2014-04-01
To determine the prevalence of dry eye syndrome in the general 40- to 64-year-old population of Shahroud, Iran. Population-based cross-sectional study. Through cluster sampling, 6311 people were selected and 5190 participated. Assessment of dry eye was done in a random subsample of 1008 people. Subjective assessment for dry eye syndrome was performed using Ocular Surface Disease Index questionnaire. In addition, the following objective tests of dry eye syndrome were employed: Schirmer test, tear break-up time, and fluorescein and Rose Bengal staining using the Oxford grading scheme. Those with an Ocular Surface Disease Index score ≥23 were considered symptomatic, and dry eye syndrome was defined as having symptoms and at least one positive objective sign. The prevalence of dry eye syndrome was 8.7% (95% confidence interval 6.9-10.6). Assessment of signs showed an abnormal Schirmer score in 17.8% (95% confidence interval 15.5-20.0), tear break-up time in 34.2% (95% confidence interval 29.5-38.8), corneal fluorescein staining (≥1) in 11.3% (95% confidence interval 8.5-14.1) and Rose Bengal staining (≥3 for cornea and/or conjunctiva) in 4.9% (95% confidence interval 3.4-6.5). According to the Ocular Surface Disease Index scores, 18.3% (95% confidence interval 15.9-20.6) had dry eye syndrome symptoms. The prevalence of dry eye syndrome was significantly higher in women (P = 0.010) and not significantly associated with age (P = 0.291). The objective dry eye syndrome signs significantly increased with age. Based on the findings, the prevalence of dry eye syndrome in the studied population is in the mid-range. The prevalence is higher in women. Also, objective tests tend to turn abnormal at higher age. Pterygium is associated with dry eye syndrome and increased its symptoms. © 2013 Royal Australian and New Zealand College of Ophthalmologists.
Extralenticular and Lenticular Aspects of Accommodation and Presbyopia in Human Versus Monkey Eyes
Croft, Mary Ann; McDonald, Jared P.; Katz, Alexander; Lin, Ting-Li; Lütjen-Drecoll, Elke; Kaufman, Paul L.
2013-01-01
Purpose. To determine if the accommodative forward movements of the vitreous zonule and lens equator occur in the human eye, as they do in the rhesus monkey eye; to investigate the connection between the vitreous zonule posterior insertion zone and the posterior lens equator; and to determine which components—muscle apex width, lens thickness, lens equator position, vitreous zonule, circumlental space, and/or other intraocular dimensions, including those stated in the objectives above—are most important in predicting accommodative amplitude and presbyopia. Methods. Accommodation was induced pharmacologically in 12 visually normal human subjects (ages 19–65 years) and by midbrain electrical stimulation in 11 rhesus monkeys (ages 6–27 years). Ultrasound biomicroscopy imaged the entire ciliary body, anterior and posterior lens surfaces, and the zonule. Relevant distances were measured in the resting and accommodated eyes. Stepwise regression analysis determined which variables were the most important predictors. Results. The human vitreous zonule and lens equator move forward (anteriorly) during accommodation, and their movements decline with age, as in the monkey. Over all ages studied, age could explain accommodative amplitude, but not as well as accommodative lens thickening and resting muscle apex thickness did together. Accommodative change in distances between the vitreous zonule insertion zone and the posterior lens equator or muscle apex were important for predicting accommodative lens thickening. Conclusions. Our findings quantify the movements of the zonule and ciliary muscle during accommodation, and identify their age-related changes that could impact the optical change that occurs during accommodation and IOL function. PMID:23745002
Visual Depth from Motion Parallax and Eye Pursuit
Stroyan, Keith; Nawrot, Mark
2012-01-01
A translating observer viewing a rigid environment experiences “motion parallax,” the relative movement upon the observer’s retina of variously positioned objects in the scene. This retinal movement of images provides a cue to the relative depth of objects in the environment, however retinal motion alone cannot mathematically determine relative depth of the objects. Visual perception of depth from lateral observer translation uses both retinal image motion and eye movement. In (Nawrot & Stroyan, 2009, Vision Res. 49, p.1969) we showed mathematically that the ratio of the rate of retinal motion over the rate of smooth eye pursuit mathematically determines depth relative to the fixation point in central vision. We also reported on psychophysical experiments indicating that this ratio is the important quantity for perception. Here we analyze the motion/pursuit cue for the more general, and more complicated, case when objects are distributed across the horizontal viewing plane beyond central vision. We show how the mathematical motion/pursuit cue varies with different points across the plane and with time as an observer translates. If the time varying retinal motion and smooth eye pursuit are the only signals used for this visual process, it is important to know what is mathematically possible to derive about depth and structure. Our analysis shows that the motion/pursuit ratio determines an excellent description of depth and structure in these broader stimulus conditions, provides a detailed quantitative hypothesis of these visual processes for the perception of depth and structure from motion parallax, and provides a computational foundation to analyze the dynamic geometry of future experiments. PMID:21695531
Dietzel, Martha; Zeimer, Meike; Heimes, Britta; Claes, Birte; Pauleikhoff, Daniel; Hense, Hans-Werner
2011-06-01
The controversial protective effect of macular pigment (MP), consisting of lutein (L) and zeaxantin (Z), in age-related maculopathy (ARM) and its late-stage, age-related macular degeneration (AMD) is discussed. Determinants of MP optical density (MPOD) and its relation to ARM were investigated. MPOD was accessed at eccentricities of 0.5° and 2.0° from the fovea in 369 participants in the 2.6-year follow-up examination of the prospective Muenster Aging and Retina Study using dual-wavelength analysis of autofluorescence images. ARM was graded from standardized fundus photographs according to the International Classification System. MPOD at 0.5° and 2.0° between pairs and within single eyes was strongly correlated (P < 0.001). Smoking and body mass index showed moderately inverse associations with MPOD at 2.0°, and age was positively related to MPOD at both eccentricities. Serum L, measured at the baseline examination, was significantly associated with MPOD measured at follow-up. Likewise, use of L/Z-containing supplements raised MPOD. Crude mean MPOD increased with ascending stage of ARM. However, adjustment for influential factors and exclusion of L supplement users removed differences of mean MPOD between ARM stages. Considering further the accompanying eye, study eyes with ARM had significantly higher MPOD when the contralateral eye had AMD. MPOD levels showed a high degree of intraindividual concordance and interindividual variability. Long-standing serum L levels, and in particular L supplementation, were the strongest determinants of MPOD. The hypothetical inverse association between MPOD and ARM stage was not confirmed.
Mensh, B D; Aksay, E; Lee, D D; Seung, H S; Tank, D W
2004-03-01
To quantify performance of the goldfish oculomotor neural integrator and determine its dependence on visual feedback, we measured the relationship between eye drift-velocity and position during spontaneous gaze fixations in the light and in the dark. In the light, drift-velocities were typically less than 1 deg/s, similar to those observed in humans. During brief periods in darkness, drift-velocities were only slightly larger, but showed greater variance. One hour in darkness degraded fixation-holding performance. These findings suggest that while visual feedback is not essential for online fixation stability, it may be used to tune the mechanism of persistent neural activity in the oculomotor integrator.
From the Transits of Venus to the Birth of Experimental Psychology
NASA Astrophysics Data System (ADS)
Sheehan, William
2013-06-01
I trace the attempts to determine the Earth-Sun distance, which is based on measurements of the solar parallax, from the naked-eye observations of Aristarchus of Samos in antiquity to observations of the transits of Venus in the 18th century, noting the nature of the observational errors involved in them. I then turn to measurements of stellar positions with meridian or transit telescopes in the 17th to 19th centuries using the eye and ear method of observation. I show how an analysis of the observational discrepancies in this method led to the discovery of an observer's "personal equation," and ultimately to the birth of experimental psychology.
Assessment of minimum permissible geometrical parameters of a near-to-eye display.
Valyukh, Sergiy; Slobodyanyuk, Oleksandr
2015-07-20
Light weight and small dimensions are some of the most important characteristics of near-to-eye displays (NEDs). These displays consist of two basic parts: a microdisplay for generating an image and supplementary optics in order to see the image. Nowadays, the pixel size of microdisplays may be less than 4 μm, which makes the supplementary optics the major factor in defining restrictions on a NED dimensions or at least on the distance between the microdisplay and the eye. The goal of the present work is to find answers to the following two questions: how small this distance can be in principle and what is the microdisplay maximum resolution that stays effective to see through the supplementary optics placed in immediate vicinity of the eye. To explore the first question, we consider an aberration-free magnifier, which is the initial stage in elaboration of a real optical system. In this case, the paraxial approximation and the transfer matrix method are ideal tools for simulation of light propagation from the microdisplay through the magnifier and the human eye's optical system to the retina. The human eye is considered according to the Gullstrand model. Parameters of the magnifier, its location with respect to the eye and the microdisplay, and the depth of field, which can be interpreted as the tolerance of the microdisplay position, are determined and discussed. The second question related to the microdisplay maximum resolution is investigated by using the principles of wave optics.
Detection of CIN by naked eye visualization after application of acetic acid.
Londhe, M; George, S S; Seshadri, L
1997-06-01
A prospective study was undertaken to determine the sensitivity and specificity of acetic application to the cervix followed by naked eye visualization as a screening test for detection of cervical intraepithelial neoplasia. Three hundred and seventy two sexually active woman in the reproductive age group were studied. All the women underwent Papanicolaou test, acetic acid test and colposcopy. One hundred and seventy five woman were acetic acid test negative, 197 women were acetic acid test positive. The sensitivity of acetic acid test was 72.4%, specificity 54% and false negative rate 15.2%, as compared to papanicolaou test which had a sensitivity of 13.2%, specificity of 96.3% and false negative rate of 24.4%. The advantage of the acetic acid test lies in its easy technique, low cost and high sensitivity which are important factors for determining the efficacy of any screening programme in developing countries.
Sensitivity and Specificity of OCT Angiography to Detect Choroidal Neovascularization.
Faridi, Ambar; Jia, Yali; Gao, Simon S; Huang, David; Bhavsar, Kavita V; Wilson, David J; Sill, Andrew; Flaxel, Christina J; Hwang, Thomas S; Lauer, Andreas K; Bailey, Steven T
2017-01-01
To determine the sensitivity and specificity of optical coherence tomography angiography (OCTA) in the detection of choroidal neovascularization (CNV) in age-related macular degeneration (AMD). Prospective case series. Prospective series of seventy-two eyes were studied, which included eyes with treatment-naive CNV due to AMD, non-neovascular AMD, and normal controls. All eyes underwent OCTA with a spectral domain (SD) OCT (Optovue, Inc.). The 3D angiogram was segmented into separate en face views including the inner retinal angiogram, outer retinal angiogram, and choriocapillaris angiogram. Detection of abnormal flow in the outer retina served as candidate CNV with OCTA. Masked graders reviewed structural OCT alone, en face OCTA alone, and en face OCTA combined with cross-sectional OCTA for the presence of CNV. The sensitivity and specificity of CNV detection compared to the gold standard of fluorescein angiography (FA) and OCT was determined for structural SD-OCT alone, en face OCTA alone, and with en face OCTA combined with cross-sectional OCTA. Of 32 eyes with CNV, both graders identified 26 true positives with en face OCTA alone, resulting in a sensitivity of 81.3%. Four of the 6 false negatives had large subretinal hemorrhage (SRH) and sensitivity improved to 94% for both graders if eyes with SRH were excluded. The addition of cross-sectional OCTA along with en face OCTA improved the sensitivity to 100% for both graders. Structural OCT alone also had a sensitivity of 100%. The specificity of en face OCTA alone was 92.5% for grader A and 97.5% for grader B. The specificity of structural OCT alone was 97.5% for grader A and 85% for grader B. Cross-sectional OCTA combined with en face OCTA had a specificity of 97.5% for grader A and 100% for grader B. Sensitivity and specificity for CNV detection with en face OCTA combined with cross-sectional OCTA approaches that of the gold standard of FA with OCT, and it is better than en face OCTA alone. Structural OCT alone has excellent sensitivity for CNV detection. False positives from structural OCT can be mitigated with the addition of flow information with OCTA.
NASA Technical Reports Server (NTRS)
Villarreal, James
1987-01-01
A workstation was developed which uses the operator's eye movements and position to determine the placement of the cursor on a computer screen. A brainwave sensing technology overview and an introduction to the known rhythms or signals generated by the brain are given. This is followed by a descriptive explanation of the Ocular Attention Interface System (OASIS) and its intended integration into the proposed testbed.
Genead, Mohamed A; Fishman, Gerald A
2010-09-01
To determine the efficacy of sustained topical therapy with dorzolamide hydrochloride, 2%, on visual acuity and cystic macular lesions in patients with retinitis pigmentosa and Usher syndrome. In a retrospective case series at a university hospital, 64 eyes of 32 patients with retinitis pigmentosa or Usher syndrome receiving treatment with the topical dorzolamide formulation for 6 to 58 months were enrolled. Changes in visual acuity on the Early Treatment Diabetic Retinopathy Study chart and central foveal zone thickness on optical coherence tomography were measured during follow-up for the duration of treatment. Among the study cohort, 20 of 32 patients (63%) showed a positive response to treatment in at least 1 eye and 13 patients (41%) showed a positive response in both eyes. Four patients (20%) showed an initial response and a subsequent rebound of macular cysts. In 8 patients (25%), there was no response to treatment and the macular cysts worsened when compared with the pretreatment level. Ten patients (31%) had improvement in visual acuity by 7 or more letters in at least 1 eye at the most recent follow-up visit. Sixteen patients (67%) showed a reduction of more than 11% in the central foveal zone thickness in at least 1 eye when compared with the pretreatment level. Patients with either retinitis pigmentosa or Usher syndrome who received treatment of cystoid macular edema with topical dorzolamide followed by an optical coherence tomography-guided strategy showed a decrease in central foveal zone thickness in most cases. Visual acuity improved in almost one-third of the cases, suggesting a potential corresponding visual benefit.
Distinct eye movement patterns enhance dynamic visual acuity.
Palidis, Dimitrios J; Wyder-Hodge, Pearson A; Fooken, Jolande; Spering, Miriam
2017-01-01
Dynamic visual acuity (DVA) is the ability to resolve fine spatial detail in dynamic objects during head fixation, or in static objects during head or body rotation. This ability is important for many activities such as ball sports, and a close relation has been shown between DVA and sports expertise. DVA tasks involve eye movements, yet, it is unclear which aspects of eye movements contribute to successful performance. Here we examined the relation between DVA and the kinematics of smooth pursuit and saccadic eye movements in a cohort of 23 varsity baseball players. In a computerized dynamic-object DVA test, observers reported the location of the gap in a small Landolt-C ring moving at various speeds while eye movements were recorded. Smooth pursuit kinematics-eye latency, acceleration, velocity gain, position error-and the direction and amplitude of saccadic eye movements were linked to perceptual performance. Results reveal that distinct eye movement patterns-minimizing eye position error, tracking smoothly, and inhibiting reverse saccades-were related to dynamic visual acuity. The close link between eye movement quality and DVA performance has important implications for the development of perceptual training programs to improve DVA.
Distinct eye movement patterns enhance dynamic visual acuity
Palidis, Dimitrios J.; Wyder-Hodge, Pearson A.; Fooken, Jolande; Spering, Miriam
2017-01-01
Dynamic visual acuity (DVA) is the ability to resolve fine spatial detail in dynamic objects during head fixation, or in static objects during head or body rotation. This ability is important for many activities such as ball sports, and a close relation has been shown between DVA and sports expertise. DVA tasks involve eye movements, yet, it is unclear which aspects of eye movements contribute to successful performance. Here we examined the relation between DVA and the kinematics of smooth pursuit and saccadic eye movements in a cohort of 23 varsity baseball players. In a computerized dynamic-object DVA test, observers reported the location of the gap in a small Landolt-C ring moving at various speeds while eye movements were recorded. Smooth pursuit kinematics—eye latency, acceleration, velocity gain, position error—and the direction and amplitude of saccadic eye movements were linked to perceptual performance. Results reveal that distinct eye movement patterns—minimizing eye position error, tracking smoothly, and inhibiting reverse saccades—were related to dynamic visual acuity. The close link between eye movement quality and DVA performance has important implications for the development of perceptual training programs to improve DVA. PMID:28187157
Ali, S M; Reisner, L A; King, B; Cao, A; Auner, G; Klein, M; Pandya, A K
2008-01-01
A redesigned motion control system for the medical robot Aesop allows automating and programming its movements. An IR eye tracking system has been integrated with this control interface to implement an intelligent, autonomous eye gaze-based laparoscopic positioning system. A laparoscopic camera held by Aesop can be moved based on the data from the eye tracking interface to keep the user's gaze point region at the center of a video feedback monitor. This system setup provides autonomous camera control that works around the surgeon, providing an optimal robotic camera platform.
Optical, gravitational, and kinesthetic determinants of judged eye level
NASA Technical Reports Server (NTRS)
Stoper, Arnold E.; Cohen, Malcolm M.
1989-01-01
Subjects judged eye level, defined in three distinct ways relative to three distinct reference planes: a gravitational horizontal, giving the gravitationally referenced eye level (GREL); a visible surface, giving the surface-referenced eye level (SREL); and a plane fixed with respect to the head, giving the head-referenced eye level (HREL). The information available for these judgements was varied by having the subjects view an illuminated target that could be placed in a box which: (1) was pitched at various angles, (2) was illuminated or kept in darkness, (3) was moved to different positions along the subject's head-to-foot body axis, and (4) was viewed with the subjects upright or reclining. The results showed: (1) judgements of GREL made in the dark were 2.5 deg lower than in the light, with a significantly greater variability; (2) judged GREL was shifted approximately half of the way toward SREL when these two eye levels did not coincide; (3) judged SREL was shifted about 12 percent of the way toward HREL when these two eye levels did not coincide, (4) judged HREL was shifted about half way toward SREL when these two eye level did not coincide and when the subject was upright (when the subject was reclining, HREL was shifted approx. 90 percent toward SREL); (5) the variability of the judged HREL in the dark was nearly twice as great with the subject reclining than with the subject upright. These results indicate that gravity is an important source of information for judgement of eye level. In the absence of information concerning the direction of gravity, the ability to judge HREL is extremely poor. A visible environment does not seem to afford precise information as to judgements of direction, but it probably does afford significant information as to the stability of these judgements.
Myopic refractive shift represents dense nuclear sclerosis and thin lens in lenticular myopia.
Cho, Yang Kyung; Huang, Wei; Nishimura, Eiichi
2013-09-01
It is not rare to meet unilateral nuclear sclerotic cataracts with myopic refractive changes (lenticular myopia) compared with the fellow eye in the ophthalmic examination of patients with decreased visual acuity. To determine the relationship between the myopic refractive changes and interocular differences of parameters, we investigated the interocular differences of ocular parameters between a lenticular myopic eye and the fellow eye. This retrospective study included 68 eyes of 34 patients, who showed unilateral lenticular myopia. We compared the dimensions of ocular component, such as anterior chamber depth, anterior chamber volume, lens thickness, vitreous chamber depth, lens position, lens density of nuclear sclerosis, anterior lens curvature and myopic refractive changes (spherical equivalent refraction) between the lenticular myopic eye and the myopic refractive change were examined. Statistically significant differences were found between the lenticular myopic eye and the fellow eye for anterior chamber depth (p = 0.015) anterior chamber volume (p = 0.031), lens thickness (p < 0.001), lens density of the nuclear sclerosis (p < 0.001) and the spherical equivalent myopic refractive changes (p < 0.001). Based on univariate analysis, the interocular difference in spherical equivalent refraction was significantly correlated with interocular differences of the density of the nuclear sclerosis (r = 0.79, p < 0.001), lens thickness (r = -0.70, p < 0.001) and vitreous chamber depth (r = 0.43, p = 0.012). Based on multiple regression analysis, the interocular difference in spherical equivalent refraction was significantly correlated with interocular differences of density of nuclear sclerosis (p < 0.001) and lens thickness (p = 0.007). The difference in myopic spherical change reflects the differences in the severity of nuclear sclerosis and lens thickness between the lenticular myopic eye and the fellow eye. © 2013 The Authors. Clinical and Experimental Optometry © 2013 Optometrists Association Australia.
Nakashima, Ryoichi; Shioiri, Satoshi
2014-01-01
Why do we frequently fixate an object of interest presented peripherally by moving our head as well as our eyes, even when we are capable of fixating the object with an eye movement alone (lateral viewing)? Studies of eye-head coordination for gaze shifts have suggested that the degree of eye-head coupling could be determined by an unconscious weighing of the motor costs and benefits of executing a head movement. The present study investigated visual perceptual effects of head direction as an additional factor impacting on a cost-benefit organization of eye-head control. Three experiments using visual search tasks were conducted, manipulating eye direction relative to head orientation (front or lateral viewing). Results show that lateral viewing increased the time required to detect a target in a search for the letter T among letter L distractors, a serial attentive search task, but not in a search for T among letter O distractors, a parallel preattentive search task (Experiment 1). The interference could not be attributed to either a deleterious effect of lateral gaze on the accuracy of saccadic eye movements, nor to potentially problematic optical effects of binocular lateral viewing, because effect of head directions was obtained under conditions in which the task was accomplished without saccades (Experiment 2), and during monocular viewing (Experiment 3). These results suggest that a difference between the head and eye directions interferes with visual processing, and that the interference can be explained by the modulation of attention by the relative positions of the eyes and head (or head direction). PMID:24647634
Higher Level Visual Cortex Represents Retinotopic, Not Spatiotopic, Object Location
Kanwisher, Nancy
2012-01-01
The crux of vision is to identify objects and determine their locations in the environment. Although initial visual representations are necessarily retinotopic (eye centered), interaction with the real world requires spatiotopic (absolute) location information. We asked whether higher level human visual cortex—important for stable object recognition and action—contains information about retinotopic and/or spatiotopic object position. Using functional magnetic resonance imaging multivariate pattern analysis techniques, we found information about both object category and object location in each of the ventral, dorsal, and early visual regions tested, replicating previous reports. By manipulating fixation position and stimulus position, we then tested whether these location representations were retinotopic or spatiotopic. Crucially, all location information was purely retinotopic. This pattern persisted when location information was irrelevant to the task, and even when spatiotopic (not retinotopic) stimulus position was explicitly emphasized. We also conducted a “searchlight” analysis across our entire scanned volume to explore additional cortex but again found predominantly retinotopic representations. The lack of explicit spatiotopic representations suggests that spatiotopic object position may instead be computed indirectly and continually reconstructed with each eye movement. Thus, despite our subjective impression that visual information is spatiotopic, even in higher level visual cortex, object location continues to be represented in retinotopic coordinates. PMID:22190434
Evaluating the efficacy of fully automated approaches for the selection of eye blink ICA components
Pontifex, Matthew B.; Miskovic, Vladimir; Laszlo, Sarah
2017-01-01
Independent component analysis (ICA) offers a powerful approach for the isolation and removal of eye blink artifacts from EEG signals. Manual identification of the eye blink ICA component by inspection of scalp map projections, however, is prone to error, particularly when non-artifactual components exhibit topographic distributions similar to the blink. The aim of the present investigation was to determine the extent to which automated approaches for selecting eye blink related ICA components could be utilized to replace manual selection. We evaluated popular blink selection methods relying on spatial features [EyeCatch()], combined stereotypical spatial and temporal features [ADJUST()], and a novel method relying on time-series features alone [icablinkmetrics()] using both simulated and real EEG data. The results of this investigation suggest that all three methods of automatic component selection are able to accurately identify eye blink related ICA components at or above the level of trained human observers. However, icablinkmetrics(), in particular, appears to provide an effective means of automating ICA artifact rejection while at the same time eliminating human errors inevitable during manual component selection and false positive component identifications common in other automated approaches. Based upon these findings, best practices for 1) identifying artifactual components via automated means and 2) reducing the accidental removal of signal-related ICA components are discussed. PMID:28191627
Fan, X; Wu, L L; Xiao, G G; Ma, Z Z; Liu, F
2018-03-11
Objective: To analyze potentials of frequency-doubling technology perimetry (FDP) for diagnosing open-angle glaucoma (OAG) in perimetrically normal eyes of OAG patients diagnosed with standard automated perimetry (SAP) and relating factors from abnormalities on FDP to visual field loss on SAP. Methods: A prospective cohort study. Sixty-eight eyes of 68 OAG patients visiting the ophthalmic clinic of Peking University Third Hospital during November 2003 and October 2007 [32 primary open-angle glaucoma patients and 36 normal tension glaucoma patients, 32 males and 36 females, with an average age of (59±13) years] with unilateral field loss detected by SAP (Octopus101 tG2 program) were examined with the FDP N-30 threshold program (Humphrey Instruments) at baseline. Two groups, FDP positive group and FDP negative group, were divided based on the FDP results, and visual field examinations were followed by a series of SAP examinations for the perimetrically normal eyes over 8 years. During the follow-up, the difference of the converting rate of SAP tests between the two groups was analyzed. Differences between "convertors" and "non-convertors" of SAP tests in the FDP positive group, such as the cup-to-disk ratio and glaucomatous optic neuropathy rate, were also compared with the independent-sample t test or Wilcoxon two-sample test for continuous variable data and the χ(2) test or Fisher exact test for classified variable data and rates. Results: Forty-eight perimetrically normal eyes of 48 participants had complete data and a qualifying follow-up. Baseline FDP results were positive in 33 eyes and negative in 15 eyes. Of the eyes with positive FDP results, 22 eyes developed abnormal SAP results after 4.0 to 90.0 months (median 14.5 months) , whereas none of the eyes with negative FDP results developed abnormal SAP results. For perimetrically normal eyes in the FDP positive group, "converters" showed a greater cup-to-disk ratio (0.73±0.09 vs . 0.63±0.14, Wilcoxon two-sample test, P= 0.011) and more eyes with glaucomatous optic neuropathy (19/22 vs . 4/11, Fisher exact test, P= 0.006). Conclusions: In perimetrically normal eyes of OAG patients, FDP could detect visual field loss of these eyes and predict to some extent future visual field loss on SAP. Severity of glaucomatous optic neuropathy at baseline is related to converting from abnormalities on FDP to visual field loss on SAP. (Chin J Ophthalmol, 2018, 54: 177-183) .
The perception of heading during eye movements
NASA Technical Reports Server (NTRS)
Royden, Constance S.; Banks, Martin S.; Crowell, James A.
1992-01-01
Warren and Hannon (1988, 1990), while studying the perception of heading during eye movements, concluded that people do not require extraretinal information to judge heading with eye/head movements present. Here, heading judgments are examined at higher, more typical eye movement velocities than the extremely slow tracking eye movements used by Warren and Hannon. It is found that people require extraretinal information about eye position to perceive heading accurately under many viewing conditions.
Extraocular muscle proprioception and eye position.
Pettorossi, V E; Ferraresi, A; Draicchio, F; Errico, P; Santarelli, R; Manni, E
1995-03-01
In the lamb, acute unilateral section of the ophthalmic branch induced in the ipsilateral eye occasional oscillations of the resting position and misalignment of the horizontal vestibulo-ocular reflex (HVOR) with respect to the stimulus. Additional electrolytic lesion of the cells innervating the proprioceptors of the medial rectus muscle, or of the lateral rectus muscle in the contralateral semilunar ganglion, provoked a 4 degrees-7 degrees consensual eye deviation towards and away from the lesioned side, respectively. The optokinetic beating field was similarly deviated. Under these experimental conditions, HVOR showed enhanced gain and marked misalignment in both eyes. Therefore, the selective suppression of muscular proprioceptive input deviated both eyes towards the direction opposite to the muscle whose gangliar proprioceptive representation has been destroyed.
Effect of gravity on vertical eye position.
Pierrot-Deseilligny, C
2009-05-01
There is growing evidence that gravity markedly influences vertical eye position and movements. A new model for the organization of brainstem upgaze pathways is presented in this review. The crossing ventral tegmental tract (CVTT) could be the efferent tract of an "antigravitational" pathway terminating at the elevator muscle motoneurons in the third nerve nuclei and comprising, upstream, the superior vestibular nucleus and y-group, the flocculus, and the otoliths. This pathway functions in parallel to the medial longitudinal fasciculus pathways, which control vertical eye movements made to compensate for all vertical head movements and may also comprise the "gravitational" vestibular pathways, involved in the central reflection of the gravity effect. The CVTT could provide the upgaze system with the supplement of tonic activity required to counteract the gravity effect expressed in the gravitational pathway, being permanently modulated according to the static positions of the head (i.e., the instantaneous gravity vector) between a maximal activity in the upright position and a minimal activity in horizontal positions. Different types of arguments support this new model. The permanent influence of gravity on vertical eye position is strongly suggested by the vertical slow phases and nystagmus observed after rapid changes in hypo- or hypergravity. The chin-beating nystagmus, existing in normal subjects with their head in the upside-down position, suggests that gravity is not compensated for in the downgaze system. Upbeat nystagmus due to brainstem lesions, most likely affecting the CVTT circuitry, is improved when the head is in the horizontal position, suggesting that this circuitry is involved in the counteraction of gravity between the upright and horizontal positions of the head. In downbeat nystagmus due to floccular damage, in which a permanent hyperexcitation of the CVTT could exist, a marked influence of static positions of the head is also observed. Finally, the strongest argument supporting a marked role of gravity in vertical eye position is that the eye movement alterations observed in the main, typical physiological and pathological conditions are precisely those that would be expected from a direct effect of gravity on the eyeballs, with, moreover, no single alternative interpretation existing so far that could account for all these different types of findings.
Are Eyes a Mirror of the Soul? What Eye Wrinkles Reveal about a Horse’s Emotional State
Hintze, Sara; Smith, Samantha; Patt, Antonia; Bachmann, Iris; Würbel, Hanno
2016-01-01
Finding valid indicators of emotional states is one of the biggest challenges in animal welfare science. Here, we investigated in horses whether variation in the expression of eye wrinkles caused by contraction of the inner eyebrow raiser reflects emotional valence. By confronting horses with positive and negative conditions, we aimed to induce positive and negative emotional states, hypothesising that positive emotions would reduce whereas negative emotions would increase eye wrinkle expression. Sixteen horses were individually exposed in a balanced order to two positive (grooming, food anticipation) and two negative conditions (food competition, waving a plastic bag). Each condition lasted for 60 seconds and was preceded by a 60 second control phase. Throughout both phases, pictures of the eyes were taken, and for each horse four pictures per condition and phase were randomly selected. Pictures were scored in random order and by two experimenters blind to condition and phase for six outcome measures: qualitative impression, eyelid shape, markedness of the wrinkles, presence of eye white, number of wrinkles, and the angle between the line through the eyeball and the highest wrinkle. The angle decreased during grooming and increased during food competition compared to control phases, whereas the two phases did not differ during food anticipation and the plastic bag condition. No effects on the other outcome measures were detected. Taken together, we have defined a set of measures to assess eye wrinkle expression reliably, of which one measure was affected by the conditions the horses were exposed to. Variation in eye wrinkle expression might provide valuable information on horse welfare but further validation of specific measures across different conditions is needed. PMID:27732647
Bakst, Leah; Fleuriet, Jérome; Mustari, Michael J
2017-05-01
Neurons in the smooth eye movement subregion of the frontal eye field (FEFsem) are known to play an important role in voluntary smooth pursuit eye movements. Underlying this function are projections to parietal and prefrontal visual association areas and subcortical structures, all known to play vital but differing roles in the execution of smooth pursuit. Additionally, the FEFsem has been shown to carry a diverse array of signals (e.g., eye velocity, acceleration, gain control). We hypothesized that distinct subpopulations of FEFsem neurons subserve these diverse functions and projections, and that the relative weights of retinal and extraretinal signals could form the basis for categorization of units. To investigate this, we used a step-ramp tracking task with a target blink to determine the relative contributions of retinal and extraretinal signals in individual FEFsem neurons throughout pursuit. We found that the contributions of retinal and extraretinal signals to neuronal activity and behavior change throughout the time course of pursuit. A clustering algorithm revealed three distinct neuronal subpopulations: cluster 1 was defined by a higher sensitivity to eye velocity, acceleration, and retinal image motion; cluster 2 had greater activity during blinks; and cluster 3 had significantly greater eye position sensitivity. We also performed a comparison with a sample of medial superior temporal neurons to assess similarities and differences between the two areas. Our results indicate the utility of simple tests such as the target blink for parsing the complex and multifaceted roles of cortical areas in behavior. NEW & NOTEWORTHY The frontal eye field (FEF) is known to play a critical role in volitional smooth pursuit, carrying a variety of signals that are distributed throughout the brain. This study used a novel application of a target blink task during step ramp tracking to determine, in combination with a clustering algorithm, the relative contributions of retinal and extraretinal signals to FEF activity and the extent to which these contributions could form the basis for a categorization of neurons. Copyright © 2017 the American Physiological Society.
Ophthalmic Diagnostics Using a New Dynamic Light Scattering Fiber Optic Probe
NASA Technical Reports Server (NTRS)
Ansari, Rafat R.; Suh, Kwang I.; Dellavecchia, Michael A.; Dubin, Stephen
1995-01-01
A new fiber optic probe is developed to study different parts of the eye. The probe positioned in front of an eye, delivers a low power light from a laser diode into the eye and guides the light which is back scattered by different components (aqueous humor, lens, and vitreous humor) of the eye through a receiving optical fiber to a photo detector. The probe provides rapid determination of macromolecular diffusivities and their respective size distributions in the eye lens and the gel-like material in the vitreous humor. We report alpha-crystalline size distributions, as a function of penetration depth, inside the lens and hyaluronic acid molecular size distribution in the vitreous body. In a clinical setting, the probe can be mounted on a slit-lamp apparatus simply by using a H-ruby lens holder. The capability of detecting cataracts, both nuclear and peripheral, in their early stages of formation, in a non invasive and quantitative fashion, has the potential in patient monitoring and in developing and testing new drugs or diet therapies to 'dissolve' or slow down the cataract formation before surgery is necessary. The ability to detect biochemical and macromolecular changes in the vitreous structure can be very useful in identifying certain diseases of the posterior chamber, e.g., posterior vitreous detachment.
Tejada-Palacios, P; Zarratea, L; Moral, M; de la Cruz-Bértolo, J
2015-08-01
To determine the performance of RetCam vs. binocular ophthalmoscopy (BIO) in a screening program for retinopathy of prematurity (ROP). Observational comparative study with prospective data collection. Examinations with RetCam (n=169) were performed on 83 infants included in a screening program for ROP and stored for analysis at a later stage. An experienced ophthalmologist examined the ocular fundus with binocular indirect ophthalmoscopy (BIO). The RetCam images were assessed for the presence of ROP, zone, grade, and presence of plus disease. RetCam and BIO data were compared by visually to estimate sensitivity, specificity, positive (VPP) and negative (VPN) predictive values. ROP disease was detected in 108 eyes with BIO, and in 74 with RetCam. Out of 306 eyes examined with RetCam, false negative results were found in 34 eyes, with no false positives. Sensitivity of RetCam exam vs. BIO was 0.68, and specificity was 0.99. Positive predictive value was 0.93 and negative predictive value was 0.85. All 34 ROP cases not detected with RetCam were in zone III or outer zone II. They were all mild and regressed spontaneously. No threshold ROP was missed with RetCam. Binocular indirect ophthalmoscopy is the reference method for the diagnosis of ROP. RetCam may be used as an alternative for ROP screening. Copyright © 2010 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.
Horváth, Gábor; Buchta, Krisztián; Varjú, Dezsö
2003-06-01
It is a well-known phenomenon that when we look into the water with two aerial eyes, both the apparent position and the apparent shape of underwater objects are different from the real ones because of refraction at the water surface. Earlier studies of the refraction-distorted structure of the underwater binocular visual field of aerial observers were restricted to either vertically or horizontally oriented eyes. We investigate a generalized version of this problem: We calculate the position of the binocular image point of an underwater object point viewed by two arbitrarily positioned aerial eyes, including oblique orientations of the eyes relative to the flat water surface. Assuming that binocular image fusion is performed by appropriate vergent eye movements to bring the object's image onto the foveas, the structure of the underwater binocular visual field is computed and visualized in different ways as a function of the relative positions of the eyes. We show that a revision of certain earlier treatments of the aerial imaging of underwater objects is necessary. We analyze and correct some widespread erroneous or incomplete representations of this classical geometric optical problem that occur in different textbooks. Improving the theory of aerial binocular imaging of underwater objects, we demonstrate that the structure of the underwater binocular visual field of aerial observers distorted by refraction is more complex than has been thought previously.
Jirsova, Katerina; Brejchova, Kristyna; Krabcova, Ivana; Filipec, Martin; Al Fakih, Aref; Palos, Michalis; Vesela, Viera
2014-01-01
To assess the impact of autologous serum (AS) eye drops on the ocular surface of patients with bilateral severe dry eye and to draw a comparison between the clinical and laboratory examinations and the degree of subjective symptoms before and after serum treatment. A three-month prospective study was conducted on 17 patients with severe dry eye. AS eye drops were applied a maximum of 12 times a day together with regular therapy. Dry eye status was evaluated by clinical examination (visual acuity, Schirmer test, tear film breakup time, vital staining, tear film debris and meniscus), conjunctival impression cytology (epithelial and goblet cell density, snake-like chromatin, HLA-DR-positive and apoptotic cells) and subjectively by the patients. The application of AS eye drops led to a significant improvement in the Schirmer test (p < 0.01) and tear film debris (p < 0.05). The densities of goblet (p < 0.0001) and epithelial cells (p < 0.05) were significantly increased, indicating a decrease of squamous metaplasia after AS treatment. A significant decrease (p < 0.05) was found in the number of apoptotic, HLA-DR-positive and snake-like chromatin cells on the ocular surface. A significant improvement was found in all evaluated subjective symptoms. Altogether, the clinical results were improved in 77%, the laboratory results in 75% and the subjective feelings in 63% of the eyes. We found that three-month AS treatment led especially to the improvement of ocular surface dryness and damage of the epithelium. The improvement of dry eye after AS treatment correlated well with the clinical, laboratory and subjective findings. From the patients' subjective point of view, the positive effect of AS decreased with time, but still persisted up to three months after the end of therapy.
Non-invasive method of measuring cerebral spinal fluid pressure
NASA Technical Reports Server (NTRS)
Borchert, Mark S. (Inventor); Lambert, James L. (Inventor)
2000-01-01
The invention provides a method of non-invasively determining intracranial pressure from measurements of an eye. A parameter of an optic nerve of the eye is determined, along with an intraocular pressure of the eye. The intracranial pressure may be determined from the intraocular pressure and the parameter.
Directional templates for real-time detection of coronal axis rotated faces
NASA Astrophysics Data System (ADS)
Perez, Claudio A.; Estevez, Pablo A.; Garate, Patricio
2004-10-01
Real-time face and iris detection on video images has gained renewed attention because of multiple possible applications in studying eye function, drowsiness detection, virtual keyboard interfaces, face recognition, video processing and multimedia retrieval. In this paper, a study is presented on using directional templates in the detection of faces rotated in the coronal axis. The templates are built by extracting the directional image information from the regions of the eyes, nose and mouth. The face position is determined by computing a line integral using the templates over the face directional image. The line integral reaches a maximum when it coincides with the face position. It is shown an improvement in localization selectivity by the increased value in the line integral computed with the directional template. Besides, improvements in the line integral value for face size and face rotation angle was also found through the computation of the line integral using the directional template. Based on these results the new templates should improve selectivity and hence provide the means to restrict computations to a fewer number of templates and restrict the region of search during the face and eye tracking procedure. The proposed method is real time, completely non invasive and was applied with no background limitation and normal illumination conditions in an indoor environment.
Kumar, Sandeep; Garg, Sandeep; Gupta, Seema
2013-02-01
The purpose of this study was to determine accurately the part of the tragus to be used to form the Ala-Tragal line or Camper's line in orthognathic profile patients. 150 dentate subjects with age of 18-40 years with orthognathic profile were sampled. Life-size lateral digital photographs of the face with fox plane were taken in natural head position. Different angles between Eye-Ear plane and occlusal plane (OT1-OP), Eye-Ear plane and ala-superior border of tragus (OT1-AT1), Eye-Ear plane and ala-middle border of tragus (OT1-AT2) and Eye-Ear plane and ala-inferior border of tragus (OT1-AT3) were calculated using computer software package, AutoCAD 2004. From the three angles formed by the Eye-ear plane (OT1 or FH plane) and the ala-tragal lines, the one closest to the angle formed between Eye-Ear plane (OT1) and occlusal plane (OP) was used to determine the occlusal plane of orientation. The obtained results were subjected to ANOVA F test, Tukey's Honestly significant difference test, followed by Karl Pearson coefficient of correlation test. P values of less than 0.05 were taken as statistically significant. The mean of base line angle i.e. OT1-OP angle (11.96 ± 4.36) was found to be close to OT1-AT2 angle (13.67 ± 1.93) and OT1-AT3 angle (10.31 ± 2.03), but OT1-OP angle was found to be more closer to OT1-AT3 angle. Comparison of mean angles showed that OT1-OP angle in both males (11.68) and females (12.51) is close to OT1-AT3 angle (males- 11.01, females- 11.95). The line joining from ala to the lower border of the tragus was parallel to the occlusal plane in 53.3% of the subjects. There was no influence of the sex on the level of occlusal plane.
Garg, Sandeep; Gupta, Seema
2013-01-01
PURPOSE The purpose of this study was to determine accurately the part of the tragus to be used to form the Ala-Tragal line or Camper's line in orthognathic profile patients. MATERIALS AND METHODS 150 dentate subjects with age of 18-40 years with orthognathic profile were sampled. Life-size lateral digital photographs of the face with fox plane were taken in natural head position. Different angles between Eye-Ear plane and occlusal plane (OT1-OP), Eye-Ear plane and ala-superior border of tragus (OT1-AT1), Eye-Ear plane and ala-middle border of tragus (OT1-AT2) and Eye-Ear plane and ala-inferior border of tragus (OT1-AT3) were calculated using computer software package, AutoCAD 2004. From the three angles formed by the Eye-ear plane (OT1 or FH plane) and the ala-tragal lines, the one closest to the angle formed between Eye-Ear plane (OT1) and occlusal plane (OP) was used to determine the occlusal plane of orientation. The obtained results were subjected to ANOVA F test, Tukey's Honestly significant difference test, followed by Karl Pearson coefficient of correlation test. P values of less than 0.05 were taken as statistically significant. RESULTS The mean of base line angle i.e. OT1-OP angle (11.96 ± 4.36) was found to be close to OT1-AT2 angle (13.67 ± 1.93) and OT1-AT3 angle (10.31 ± 2.03), but OT1-OP angle was found to be more closer to OT1-AT3 angle. Comparison of mean angles showed that OT1-OP angle in both males (11.68) and females (12.51) is close to OT1-AT3 angle (males- 11.01, females- 11.95). CONCLUSION The line joining from ala to the lower border of the tragus was parallel to the occlusal plane in 53.3% of the subjects. There was no influence of the sex on the level of occlusal plane. PMID:23508203
Depth-estimation-enabled compound eyes
NASA Astrophysics Data System (ADS)
Lee, Woong-Bi; Lee, Heung-No
2018-04-01
Most animals that have compound eyes determine object distances by using monocular cues, especially motion parallax. In artificial compound eye imaging systems inspired by natural compound eyes, object depths are typically estimated by measuring optic flow; however, this requires mechanical movement of the compound eyes or additional acquisition time. In this paper, we propose a method for estimating object depths in a monocular compound eye imaging system based on the computational compound eye (COMPU-EYE) framework. In the COMPU-EYE system, acceptance angles are considerably larger than interommatidial angles, causing overlap between the ommatidial receptive fields. In the proposed depth estimation technique, the disparities between these receptive fields are used to determine object distances. We demonstrate that the proposed depth estimation technique can estimate the distances of multiple objects.
Methods and Devices for Space Optical Communications Using Laser Beams
NASA Technical Reports Server (NTRS)
Goorjian, Peter M. (Inventor)
2018-01-01
Light is used to communicate between objects separated by a large distance. Light beams are received in a telescopic lens assembly positioned in front of a cat's-eye lens. The light can thereby be received at various angles to be output by the cat's-eye lens to a focal plane of the cat's-eye lens, the position of the light beams upon the focal plane corresponding to the angle of the beam received. Lasers and photodetectors are distributed along this focal plane. A processor receives signals from the photodetectors, and selectively signal lasers positioned proximate the photodetectors detecting light, in order to transmit light encoding data through the cat's-eye lens and also through a telescopic lens back in the direction of the received light beams, which direction corresponds to a location upon the focal plane of the transmitting lasers.
Promoting organ donation through an entertainment-education TV program in Korea: Open Your Eyes.
Byoung Kwan Lee; Hyun Soon Park; Choi, Myung-Il; Cheon Soo Kim
2010-01-01
The purpose of this study is to investigate the effects of the characteristics of the program, Open Your Eyes, an entertainment-education TV program in Korea, on parasocial interaction and behavioral intention for organ donation. The results indicated that affective evaluation positively affected parasocial interaction with the program but cognitive evaluation negatively affected involvement with beneficiaries in the program. Also, it was found that cognitive evaluation of Open Your Eyes had a significant positive effect on behavioral intention. In addition, a significant positive effect of program engagement on the behavioral intention was found. Thus, the results indicate that individuals who feel program engagement of Open Your Eyes will be more likely to proceed with organ donation. However, no direct effect of involvement with the beneficiary and program hosts was found.
Individual Differences in Affect.
ERIC Educational Resources Information Center
Haviland, Jeannette
This paper argues that infants' affect patterns are innate and are meaningful indicators of individual differences in internal state. Videotapes of seven infants' faces were coded using an ethogram; the movement of the eyebrow, eye direction, eye openness, mouth shape, mouth position, lip position, and tongue protrusion were assessed…
Opposite Effects of Glucagon and Insulin on Compensation for Spectacle Lenses in Chicks
Zhu, Xiaoying; Wallman, Josh
2009-01-01
Purpose Chick eyes compensate for defocus imposed by positive or negative spectacle lenses. Glucagon may signal the sign of defocus. Do insulin (or IGF-1) and glucagon act oppositely in controlling eye growth, as they do in metabolic pathways and in control of retinal neurogenesis? Methods Chicks, wearing either lenses or diffusers or neither over both eyes, were injected with glucagon, a glucagon antagonist, insulin, or IGF-1 in one eye (saline in other eye). Alternatively, chicks without lenses received insulin plus glucagon in one eye, and either glucagon or insulin in the fellow eye. Ocular dimensions, refractive errors and glycosaminoglycan synthesis were measured over 2-4 days. Results Glucagon attenuated the myopic response to negative lenses or diffusers by slowing ocular elongation and thickening the choroid; in contrast, with positive lenses, it increased ocular elongation to normal levels and reduced choroidal thickening, as did a glucagon antagonist. Insulin prevented the hyperopic response to positive lenses by speeding ocular elongation and thinning the choroid. In eyes without lenses, both insulin and IGF-1 speeded, and glucagon slowed, ocular elongation, but either glucagon or insulin increased the rate of thickening of the crystalline lens. When injected together, insulin blocked choroidal thickening by glucagon, at a dose that did not, by itself, thin the choroid. Conclusions Glucagon and insulin (or IGF-1) cause generally opposite modulations of eye-growth, with glucagon mostly increasing choroidal thickness and insulin mostly increasing ocular elongation. These effects are mutually inhibitory and depend on the visual input. PMID:18791176
ELECTRICAL STUDIES ON THE COMPOUND EYE OF LIGIA OCCIDENTALIS DANA (CRUSTACEA: ISOPODA)
Ruck, Philip; Jahn, Theodore L.
1954-01-01
The ERG of the compound eye in freshly collected Ligia occidentalis, in response to high intensity light flashes of ⅛ second or longer duration, begins with a negative on-effect quickly followed by an early positive deflection, rapidly returns to the baseline during illumination, and ends with a positive off-effect. As the stimulus intensity is decreased the early positivity progressively decreases and the rapid return to the baseline is replaced by a slowing decline of the negative on-effect. Responses were recorded with one active electrode subcorneally situated in the illuminated eye, the reference electrode in the dark eye. The dark-adapted eye shows a facilitation of the amplitude and rates of rise and fall of the on-effect to a brief, high intensity light stimulus. This facilitation may persist for more than 2 minutes. Following light adaptation under conditions in which the human eye loses sensitivity by a factor of almost 40,000 the Ligia eye loses sensitivity by a factor of only 3. The flicker fusion frequency of the ERG may be as high as 120/second with a corneal illumination of 15,000 foot-candles. Bleeding an otherwise intact animal very rapidly results in a decline of amplitude, change of wave form, and loss of facilitation in the ERG. When the eye is deganglionated without bleeding the animal the isolated retina responds in the same manner as the intact eye. Histological examination of the Ligia receptor layer showed that each ommatidium contains three different retinula cell types, each of which may be responsible for a different aspect of the ERG. PMID:13174786
2011-01-01
Background Coleoid cephalopods (squids and octopuses) have evolved a camera eye, the structure of which is very similar to that found in vertebrates and which is considered a classic example of convergent evolution. Other molluscs, however, possess mirror, pin-hole, or compound eyes, all of which differ from the camera eye in the degree of complexity of the eye structures and neurons participating in the visual circuit. Therefore, genes expressed in the cephalopod eye after divergence from the common molluscan ancestor could be involved in eye evolution through association with the acquisition of new structural components. To clarify the genetic mechanisms that contributed to the evolution of the cephalopod camera eye, we applied comprehensive transcriptomic analysis and conducted developmental validation of candidate genes involved in coleoid cephalopod eye evolution. Results We compared gene expression in the eyes of 6 molluscan (3 cephalopod and 3 non-cephalopod) species and selected 5,707 genes as cephalopod camera eye-specific candidate genes on the basis of homology searches against 3 molluscan species without camera eyes. First, we confirmed the expression of these 5,707 genes in the cephalopod camera eye formation processes by developmental array analysis. Second, using molecular evolutionary (dN/dS) analysis to detect positive selection in the cephalopod lineage, we identified 156 of these genes in which functions appeared to have changed after the divergence of cephalopods from the molluscan ancestor and which contributed to structural and functional diversification. Third, we selected 1,571 genes, expressed in the camera eyes of both cephalopods and vertebrates, which could have independently acquired a function related to eye development at the expression level. Finally, as experimental validation, we identified three functionally novel cephalopod camera eye genes related to optic lobe formation in cephalopods by in situ hybridization analysis of embryonic pygmy squid. Conclusion We identified 156 genes positively selected in the cephalopod lineage and 1,571 genes commonly found in the cephalopod and vertebrate camera eyes from the analysis of cephalopod camera eye specificity at the expression level. Experimental validation showed that the cephalopod camera eye-specific candidate genes include those expressed in the outer part of the optic lobes, which unique to coleoid cephalopods. The results of this study suggest that changes in gene expression and in the primary structure of proteins (through positive selection) from those in the common molluscan ancestor could have contributed, at least in part, to cephalopod camera eye acquisition. PMID:21702923
Kang, Shin J.; Zhang, Qing; Patel, Samirkumar R.; Berezovsky, Damian; Yang, Hua; Wang, Yanggan; Grossniklaus, Hans E.
2013-01-01
Purpose To evaluate the utility of in vivo imaging of rabbit model of choroidal melanoma utilizing high-frequency contrast-enhanced ultrasound (HF-CE-US) with 2-or 3-dimensional modes, and to correlate the sonographic findings with histopathologic characteristics. Methods Five New Zealand white rabbits which were immunosuppressed with daily cyclosporin A were inoculated into their right eyes with aliquots of 1.5×106 / 50 µL of 92.1 human uveal melanoma cells cultured in RPMI. At week 4, the tumor-bearing eyes were imaged using high-frequency ultrasound with microbubble contrast agent to determine the 2-dimensional tumor size and relative blood volume and by 3-dimensional mode to determine tumor volume. Histologic tumor burden was quantified in enucleated eyes by ImageJ software, and microvascular density (MVD) was determined by counting vascular channels in PAS without hematoxylin sections. Results Utilizing HF-CE-US, melanomas were visualized as relatively hyperechoic regions in the images. The correlation coefficients of sonographic size or volume compared with histologic area were 0.72 and 0.70, respectively. The sonographic tumor relative blood volume correlated with the histologic tumor vascularity (R2=0.92, P=0.04) Conclusions There is a positive correlation between in vivo sonographic tumor volume/size and histologic tumor size in our rabbit choroidal melanoma model. HF-CE-US corresponds to microvascular density and blood volume. PMID:23645822
Considerations on the mechanisms of alternating skew deviation in patients with cerebellar lesions.
Zee, D S
1996-01-01
Alternating skew deviation, in which the side of the higher eye changes depending upon whether gaze is directed to the left or the right, is a frequent sign in patients with posterior fossa lesions, including those restricted to the cerebellum. Here we propose a mechanism for alternating skews related to the otolith-ocular responses to fore and aft pitch of the head in lateral-eyed animals. In lateral-eyed animals the expected response to a static head pitch is cyclorotation of the eyes. But if the eyes are rotated horizontally in the orbit, away from the primary position, a compensatory skew deviation should also appear. The direction of the skew would depend upon whether the eyes were directed to the right (left eye forward, right eye backward) or to the left (left eye backward, right eye forward). In contrast, for frontal-eyed animals, skew deviations are counterproductive because they create diplopia and interfere with binocular vision. We attribute the emergence of skew deviations in frontal-eyed animals in pathological conditions to 1) an imbalance in otolithocular pathways and 2) a loss of the component of ocular motor innervation that normally corrects for the differences in pulling directions and strengths of the various ocular muscles as the eyes change position in the orbit. Such a compensatory mechanism is necessary to ensure optimal binocular visual function during and after head motion. This compensatory mechanism may depend upon the cerebellum.
Kimmel, Daniel L.; Mammo, Dagem; Newsome, William T.
2012-01-01
From human perception to primate neurophysiology, monitoring eye position is critical to the study of vision, attention, oculomotor control, and behavior. Two principal techniques for the precise measurement of eye position—the long-standing sclera-embedded search coil and more recent optical tracking techniques—are in use in various laboratories, but no published study compares the performance of the two methods simultaneously in the same primates. Here we compare two popular systems—a sclera-embedded search coil from C-N-C Engineering and the EyeLink 1000 optical system from SR Research—by recording simultaneously from the same eye in the macaque monkey while the animal performed a simple oculomotor task. We found broad agreement between the two systems, particularly in positional accuracy during fixation, measurement of saccade amplitude, detection of fixational saccades, and sensitivity to subtle changes in eye position from trial to trial. Nonetheless, certain discrepancies persist, particularly elevated saccade peak velocities, post-saccadic ringing, influence of luminance change on reported position, and greater sample-to-sample variation in the optical system. Our study shows that optical performance now rivals that of the search coil, rendering optical systems appropriate for many if not most applications. This finding is consequential, especially for animal subjects, because the optical systems do not require invasive surgery for implantation and repair of search coils around the eye. Our data also allow laboratories using the optical system in human subjects to assess the strengths and limitations of the technique for their own applications. PMID:22912608
Odyssey of Human Creative Genius: From Astronomical Heritage to Space Technology Heritage
NASA Astrophysics Data System (ADS)
Dluzhnevskaya, Olga; Marov, Mikhail
2016-10-01
Astronomy was one of the most important sciences in the ancient world. It was rooted in naked eye observations and primitive stone instruments for astrometric measurements to determine the positions of the Sun, Moon, planets and some stars that had both practical and sacred meaning. That is why the majority of archaeoastronomical monuments are simultaneously observatories and sanctuaries, with burials and altars.
Temporal dynamics of ocular position dependence of the initial human vestibulo-ocular reflex.
Crane, Benjamin T; Tian, Junru; Demer, Joseph L
2006-04-01
While an ideal vestibulo-ocular reflex (VOR) generates ocular rotations compensatory for head motion, during visually guided movements, Listing's Law (LL) constrains the eye to rotational axes lying in Listing's Plane (LP). The present study was conducted to explore the recent proposal that the VOR's rotational axis is not collinear with the head's, but rather follows a time-dependent strategy intermediate between LL and an ideal VOR. Binocular LPs were defined during visual fixation in eight normal humans. The VOR was evoked by a highly repeatable transient whole-body yaw rotation in darkness at a peak acceleration of 2800 deg/s2. Immediately before rotation, subjects regarded targets 15 or 500 cm distant located at eye level, 20 degrees up, or 20 degrees down. Eye and head responses were compared with LL predictions in the position and velocity domains. LP orientation varied both among subjects and between individual subject's eyes, and rotated temporally with convergence by 5 +/- 5 degrees (+/-SEM). In the position domain, the eye compensated for head displacement even when the head rotated out of LP. Even within the first 20 ms from onset of head rotation, the ocular velocity axis tilted relative to the head axis by 30% +/- 8% of vertical gaze position. Saccades increased this tilt. Regardless of vertical gaze position, the ocular rotation axis tilted backward 4 degrees farther in abduction than in adduction. There was also a binocular vertical eye velocity transient and lateral tilt of the ocular axis. These disconjugate, short-latency axis perturbations appear intrinsic to the VOR and may have neural or mechanical origins.
1989-08-01
paths for integration with the off-aperture and dual-mirror VPD designs. PREFACE The goal of this work was to explore integration of an eye line-of- gaze ...Relationship in one plane between point-of- gaze on a flat scene and relative eye, detector, and scene positions...and eye line-of- gaze measurement. As a first step towards the design of an appropriate eye trac.<ing system for interface with the virtual cockpit
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-12
... Fewer Animals to Identify Chemical Eye Hazards: Revised Criteria Necessary to Maintain Equivalent Hazard... criteria using results from 3-animal tests that would provide eye hazard classification equivalent to... least 1 positive animal in a 3-animal test to identify eye hazards will provide the same or greater...
Choi, Young; Eom, Youngsub; Song, Jong Suk; Kim, Hyo Myung
2018-05-15
To compare the effect of posterior corneal astigmatism on the estimation of total corneal astigmatism using anterior corneal measurements (simulated keratometry [K]) between eyes with keratoconus and healthy eyes. Thirty-three eyes of 33 patients with keratoconus of grade I or II and 33 eyes of 33 age- and sex-matched healthy control subjects were enrolled. Anterior, posterior, and total corneal cylinder powers and flat meridians measured by a single Scheimpflug camera were analyzed. The difference in corneal astigmatism between the simulated K and total cornea was evaluated. The mean anterior, posterior, and total corneal cylinder powers of the keratoconus group (4.37 ± 1.73, 0.95 ± 0.39, and 4.36 ± 1.74 CD, respectively) were significantly greater than those of the control group (1.10 ± 0.68, 0.39 ± 0.18, and 0.97 ± 0.63 CD, respectively). The cylinder power difference between the simulated K and total cornea was positively correlated with the posterior corneal cylinder power and negatively correlated with the absolute flat meridian difference between the simulated K and total cornea in both groups. The mean magnitude of the vector difference between the astigmatism of the simulated K and total cornea of the keratoconus group (0.67 ± 0.67 CD) was significantly larger than that of the control group (0.28 ± 0.12 CD). Eyes with keratoconus had greater estimation errors of total corneal astigmatism based on anterior corneal measurement than did healthy eyes. Posterior corneal surface measurement should be more emphasized to determine the total corneal astigmatism in eyes with keratoconus. © 2018 The Korean Ophthalmological Society.
Choi, Young; Song, Jong Suk; Kim, Hyo Myung
2018-01-01
Purpose To compare the effect of posterior corneal astigmatism on the estimation of total corneal astigmatism using anterior corneal measurements (simulated keratometry [K]) between eyes with keratoconus and healthy eyes. Methods Thirty-three eyes of 33 patients with keratoconus of grade I or II and 33 eyes of 33 age- and sex-matched healthy control subjects were enrolled. Anterior, posterior, and total corneal cylinder powers and flat meridians measured by a single Scheimpflug camera were analyzed. The difference in corneal astigmatism between the simulated K and total cornea was evaluated. Results The mean anterior, posterior, and total corneal cylinder powers of the keratoconus group (4.37 ± 1.73, 0.95 ± 0.39, and 4.36 ± 1.74 cylinder diopters [CD], respectively) were significantly greater than those of the control group (1.10 ± 0.68, 0.39 ± 0.18, and 0.97 ± 0.63 CD, respectively). The cylinder power difference between the simulated K and total cornea was positively correlated with the posterior corneal cylinder power and negatively correlated with the absolute flat meridian difference between the simulated K and total cornea in both groups. The mean magnitude of the vector difference between the astigmatism of the simulated K and total cornea of the keratoconus group (0.67 ± 0.67 CD) was significantly larger than that of the control group (0.28 ± 0.12 CD). Conclusions Eyes with keratoconus had greater estimation errors of total corneal astigmatism based on anterior corneal measurement than did healthy eyes. Posterior corneal surface measurement should be more emphasized to determine the total corneal astigmatism in eyes with keratoconus. PMID:29770640
Na, Kyung-Sun; Mok, Jee-Won; Kim, Ja Yeon
2011-01-01
Purpose To determine whether proinflammatory cytokine genes were potential susceptibility candidate genes for Korean patients with non-Sjogren dry eye, we investigated the association of the interleukin 1 beta (IL1B), interleukin 6 (IL6), and interleukin 6 receptor (IL6R) variations with this disease in Korean patients. Methods Genomic DNA was extracted from blood samples of unrelated non-Sjogren dry eye patients and healthy control individuals who visited the Eye Center and Health Promotion Center of St. Mary’s Hospital in Seoul, Korea. For screening genetic variations in proinflammatory cytokine genes, the 511 (rs16944) and 31 (rs1143627) positions in the promoter region of IL1B, rs1143634 in exon 5 of IL1B, rs1800795 of the IL6 promoter, and Asp358Ala (rs8192284) of IL6R were genotyped using the polymerase chain reaction, restriction fragment length polymorphisms, and direct sequencing. Results Among the polymorphisms, rs1143634 (F105F) in exon 5 of IL1B was significantly different between the patient and control groups. The frequency of the C/T genotype in dry eye patients was decreased relative to that of the control subjects (10.4% versus 3.9%, p=0.043, OR=3.337). For the IL6R gene, the genotypic and allelic distribution of rs8192284 was different between the dry eye patients and the controls: CC genotype (p=0.017, OR=2.12) and C allele (OR=1.26). Conclusions This is the first report of genetic variation screening of proinflammatory cytokine genes in Korean non-Sjogren dry eye patients. It is suggested that rs1143634 of IL1B and rs8192284 of IL6R act as susceptibility variations in Korean non-Sjogren dry eye patients. PMID:22128229
Eye movements during the Rorschach test in schizophrenia.
Hori, Yasuko; Fukuzako, Hiroshi; Sugimoto, Yoko; Takigawa, Morikuni
2002-08-01
In order to understand relationships between scanning behaviors, characteristics of visual stimuli and the clinical symptoms in schizophrenia, eye movements of 37 schizophrenic patients and 36 controls were recorded using an eye-mark recorder during a free-response period in a Rorschach test. Four cards (I, II, V and VIII) were used. Data were analyzed during 15 s from the presentation of each card. For all cards, the number of eye fixations and the number of eye fixation areas were fewer, and total scanning length and mean scanning length were shorter for schizophrenic patients than for controls. For card II, in the non-popular response group, eye fixation frequency upon area 5 + 6 (red) was higher for schizophrenic patients. For card VIII, in the popular response group, eye fixation frequency upon area 5 + 6 (pink) was lower for schizophrenic patients. For cards II and VIII, the number of eye fixations was inversely correlated with negative symptoms. For card II, total scanning length tended to be inversely correlated with negative symptoms, and mean eye fixation time was correlated with negative symptoms. The number of eye fixation areas was inversely correlated with positive symptoms. For card VIII, eye fixation frequency in a stimulative area tended to be correlated with positive symptoms. Scanning behaviors in schizophrenic patients are affected by characteristics of visual stimuli, and partially by clinical symptoms.
Measure and Analysis of a Gaze Position Using Infrared Light Technique
2001-10-25
MEASURE AND ANALYSIS OF A GAZE POSITION USING INFRARED LIGHT TECHNIQUE Z. Ramdane-Cherif1,2, A. Naït-Ali2, J F. Motsch2, M. O. Krebs1 1INSERM E 01-17...also proposes a method to correct head movements. Keywords: eye movement, gaze tracking, visual scan path, spatial mapping. INTRODUCTION The eye gaze ...tracking has been used for clinical purposes to detect illnesses, such as nystagmus , unusual eye movements and many others [1][2][3]. It is also used
McKibbin, Martin; Farragher, Tracey; Shickle, Darren
2017-01-01
The aim of this study was to determine the prevalence of vitreoretinal interface abnormalities (VRIA), the degree of visual impairment and associations with VRIA among adults, aged 40-69 years, in the UK Biobank study. Colour fundus photographs and spectral domain optical coherence tomography images were graded for 25% of the 8359 UK Biobank participants with mild visual impairment or worse (LogMAR >0.3 or Snellen <6/12) in at least one eye. The prevalence and contribution of VRIA to visual impairment was determined and multinomial logistic regression models were used to investigate association with known risk factors and other predetermined socioeconomic, biometric, lifestyle and medical variables for cases and matched controls. The minimum prevalence of any VRIA was 17.6% and 8.1% in the eyes with and without visual impairment, respectively. VRIA were identified as the primary cause of visual impairment in 3.6% of eyes. Although epiretinal membrane and vitreomacular traction were the most common VRIA, the degree of visual impairment was typically milder with these than with other VRIA. Visual impairment with a VRIA was positively associated with increasing age (relative risk ratio (RRR) 1.22 (95% CI 1.07 to 1.40)), female gender (RRR 1.28; 1.08 to 1.52) and Asian or Asian British ethnicity (RRR 1.60; 1.10 to 2.32). VRIA are common in middle-aged adults in the UK Biobank study, especially in eyes with visual impairment. VRIA were considered to be the primary cause of visual impairment in 3.6% of all eyes with visual impairment, although there was variation in the degree of visual impairment for each type of VRIA.
Farragher, Tracey; Shickle, Darren
2017-01-01
Objective The aim of this study was to determine the prevalence of vitreoretinal interface abnormalities (VRIA), the degree of visual impairment and associations with VRIA among adults, aged 40–69 years, in the UK Biobank study. Methods and analysis Colour fundus photographs and spectral domain optical coherence tomography images were graded for 25% of the 8359 UK Biobank participants with mild visual impairment or worse (LogMAR >0.3 or Snellen <6/12) in at least one eye. The prevalence and contribution of VRIA to visual impairment was determined and multinomial logistic regression models were used to investigate association with known risk factors and other predetermined socioeconomic, biometric, lifestyle and medical variables for cases and matched controls. Results The minimum prevalence of any VRIA was 17.6% and 8.1% in the eyes with and without visual impairment, respectively. VRIA were identified as the primary cause of visual impairment in 3.6% of eyes. Although epiretinal membrane and vitreomacular traction were the most common VRIA, the degree of visual impairment was typically milder with these than with other VRIA. Visual impairment with a VRIA was positively associated with increasing age (relative risk ratio (RRR) 1.22 (95% CI 1.07 to 1.40)), female gender (RRR 1.28; 1.08 to 1.52) and Asian or Asian British ethnicity (RRR 1.60; 1.10 to 2.32). Conclusions VRIA are common in middle-aged adults in the UK Biobank study, especially in eyes with visual impairment. VRIA were considered to be the primary cause of visual impairment in 3.6% of all eyes with visual impairment, although there was variation in the degree of visual impairment for each type of VRIA. PMID:29354705
Prevalence and histopathological characteristics of corneal stromal dystrophies in Saudi Arabia.
Alzuhairy, Sultan; Alkatan, Hind M; Al-Rajhi, Ali A
2015-01-01
The aim was to determine the frequency and describe the main histopathologic features of corneal stromal dystrophy in Saudi Arabia. A single-center, retrospective analysis of 193 corneal specimens diagnosed with stromal dystrophy. All samples were retrieved from the Histopathology Department at King Khaled Eye Specialist Hospital over a 10-year period (2002 to December 31, 2011). Cases of stromal dystrophy undergoing keratoplasty were included in the study. Routine histopathologic stains and specific stains were used to determine a diagnosis. The corresponding demographic data and basic clinical/surgical information were collected via chart review. The study sample was comprised of 193 eyes. The final diagnoses were macular corneal dystrophy (MCD) in 180 (93.26%) eyes, granular corneal dystrophy (GCD) in 9 (4.66%) and lattice corneal dystrophy (LCD) in 4 (2.07%) eyes. The mean age at presentation was 27.03 years for MCD, 26.33 years for GCD and 53.75 years for LCD. The interval between diagnosis and surgical intervention was not statistically different between the macular and granular groups (P = 0.141). There was a positive family history for the MCD (37.22%) and GCD (44.44%) groups. All eyes underwent penetrating keratoplasty (PKP) except 10 MCD cases that underwent lamellar keratoplasty. Diffuse stromal deposits were present in 87.2% of MCD corneas and 66.67% of GCD corneas. Seventeen eyes with MCD were misdiagnosed as GCD. None of the LCD cases were clinically identified since all of these cases were diagnosed as corneal scarring. In eyes with MCD that underwent PKP, there was diffuse stromal involvement (in 87.22% eyes) and changes in Descemet's membrane (in 53.5% eyes). This pathological study suggested that MCD was the most common corneal stromal dystrophy that required keratoplasty in Saudi Arabia. Patient with MCD and GCD presented at a significantly younger age than LCD. The clinical diagnosis of MCD is not achieved in all cases likely due to a more severe phenotype in the Saudi population or the presence of corneal scarring that is associated with previous trachoma, which obscures the classical appearance of LCD. We believe that PKP is first-line surgical treatment, especially for MCD because it involves all corneal layers. However, deep stromal involvement and changes in Descemet's membrane in MCD should be considered when selecting the surgical procedure.
Prevalence and Histopathological Characteristics of Corneal Stromal Dystrophies in Saudi Arabia
Alzuhairy, Sultan; Alkatan, Hind M.; Al-Rajhi, Ali A.
2015-01-01
Purpose: The aim was to determine the frequency and describe the main histopathologic features of corneal stromal dystrophy in Saudi Arabia. Methods: A single-center, retrospective analysis of 193 corneal specimens diagnosed with stromal dystrophy. All samples were retrieved from the Histopathology Department at King Khaled Eye Specialist Hospital over a 10-year period (2002 to December 31, 2011). Cases of stromal dystrophy undergoing keratoplasty were included in the study. Routine histopathologic stains and specific stains were used to determine a diagnosis. The corresponding demographic data and basic clinical/surgical information were collected via chart review. Results: The study sample was comprised of 193 eyes. The final diagnoses were macular corneal dystrophy (MCD) in 180 (93.26%) eyes, granular corneal dystrophy (GCD) in 9 (4.66%) and lattice corneal dystrophy (LCD) in 4 (2.07%) eyes. The mean age at presentation was 27.03 years for MCD, 26.33 years for GCD and 53.75 years for LCD. The interval between diagnosis and surgical intervention was not statistically different between the macular and granular groups (P = 0.141). There was a positive family history for the MCD (37.22%) and GCD (44.44%) groups. All eyes underwent penetrating keratoplasty (PKP) except 10 MCD cases that underwent lamellar keratoplasty. Diffuse stromal deposits were present in 87.2% of MCD corneas and 66.67% of GCD corneas. Seventeen eyes with MCD were misdiagnosed as GCD. None of the LCD cases were clinically identified since all of these cases were diagnosed as corneal scarring. In eyes with MCD that underwent PKP, there was diffuse stromal involvement (in 87.22% eyes) and changes in Descemet's membrane (in 53.5% eyes). Conclusion: This pathological study suggested that MCD was the most common corneal stromal dystrophy that required keratoplasty in Saudi Arabia. Patient with MCD and GCD presented at a significantly younger age than LCD. The clinical diagnosis of MCD is not achieved in all cases likely due to a more severe phenotype in the Saudi population or the presence of corneal scarring that is associated with previous trachoma, which obscures the classical appearance of LCD. We believe that PKP is first-line surgical treatment, especially for MCD because it involves all corneal layers. However, deep stromal involvement and changes in Descemet's membrane in MCD should be considered when selecting the surgical procedure. PMID:25949075
Baker, Nicholas E.; Firth, Lucy C.
2015-01-01
It is thought that Retinal Determination gene products define the response made to cell-cell signals within the eye developmental field by binding to enhancers of genes that are also regulated by cell-cell signaling pathways. In Drosophila, Retinal Determination genes including Eyeless, teashirt, eyes absent, dachsous and sine oculis, are required for normal eye development and can induce ectopic eyes when mis-expressed. Characterization of the enhancers responsible for eye expression of the hedgehog, shaven, and atonal genes, as well as the dynamics of Retinal Determination gene expression themselves, now suggest a multilayered network whereby transcriptional regulation by either Retinal Determination genes or cell-cell signaling pathways can sometimes be indirect and mediated by other transcription factor intermediates. In this updated view of the interaction between extracellular information and cell intrinsic programs during development, regulation of individual genes might sometimes be several steps removed from either the Retinal Determination genes or cell-cell signaling pathways that nevertheless govern their expression. PMID:21607995
Langeslag-Smith, Miriam A; Vandal, Alain C; Briane, Vincent; Thompson, Benjamin; Anstice, Nicola S
2015-01-01
Objectives To assess the accuracy of preschool vision screening in a large, ethnically diverse, urban population in South Auckland, New Zealand. Design Retrospective longitudinal study. Methods B4 School Check vision screening records (n=5572) were compared with hospital eye department data for children referred from screening due to impaired acuity in one or both eyes who attended a referral appointment (n=556). False positive screens were identified by comparing screening data from the eyes that failed screening with hospital data. Estimation of false negative screening rates relied on data from eyes that passed screening. Data were analysed using logistic regression modelling accounting for the high correlation between results for the two eyes of each child. Primary outcome measure Positive predictive value of the preschool vision screening programme. Results Screening produced high numbers of false positive referrals, resulting in poor positive predictive value (PPV=31%, 95% CI 26% to 38%). High estimated negative predictive value (NPV=92%, 95% CI 88% to 95%) suggested most children with a vision disorder were identified at screening. Relaxing the referral criteria for acuity from worse than 6/9 to worse than 6/12 improved PPV without adversely affecting NPV. Conclusions The B4 School Check generated numerous false positive referrals and consequently had a low PPV. There is scope for reducing costs by altering the visual acuity criterion for referral. PMID:26614622
Kirag, Nukhet; Temel, Ayla Bayik
2018-01-01
INTRODUCTION: Undiagnosed and uncorrected refractive errors in childhood can negatively affect the development of vision and cause students to have low academic success and even quit school before graduation. This study aims to determine the effects of an eye health promotion program on the health protective behaviors of primary school students. MATERIALS AND METHODS: This experimental study using a pretest-posttest design with a control group was conducted in three public primary schools in Aydın, a city in the Western Anatolia Region of Turkey, between April and November 2014. The eye health promotion program was provided by the researchers to the experimental Group 2 days in 4 weeks. The data were analyzed using the t-test, Chi-square analysis, the Mann–Whitney U-test, the Wilcoxon signed-rank test, and the McNemar test. RESULTS: The average age of the students was identified as 9.0 ± 3.64 years. The students wearing glasses all in the experimental group and 53.3% in the control group were found to always wear their glasses after the education program was completed (P < 0.05). These students, 97.9% in the experimental group and 58.1% in the control group underwent eye examinations from an ophthalmologist (P < 0.05). The eye health protective behaviors of the experimental group were found to have positively changed in the final follow-up, compared to the control group (P < 0.05). CONCLUSION: The eye health promotion program was found to be effective in improving eye health protective behaviors within the experimental group. PMID:29619388
Ultra-widefield fluorescein angiography of white without pressure
Orlin, Anton; Fatoo, Aalya; Ehrlich, Joshua; D’Amico, Donald J; Chan, RV Paul; Kiss, Szilárd
2013-01-01
Purpose To describe ultra-widefield fluorescein angiography (UWFA) findings in eyes with white without pressure (WWOP) and in eyes without any obvious peripheral chorioretinal disease, and to determine if a difference exists between these two groups. Methods A retrospective review of 379 eyes undergoing diagnostic UWFA using the Optos 200Tx imaging system. Eyes were excluded if the quality of the color photograph or UWFA prevented reliable evaluation. Eyes were also excluded if there was any evidence of peripheral retinal or choroidal disease, which was thought to have an effect on UWFA (eg, peripheral background diabetic or hypertensive retinopathy, vein occlusion, or any other peripheral vascular disorder). Eyes were determined to have WWOP, based on a dilated fundus examination and color fundus photography that contained areas of peripheral retinal whitening consistent with the diagnosis. UWFA was evaluated by trained masked graders, and determined to have or not have peripheral vascular leakage and/or staining. Results Of the 379 eyes evaluated, 45 eyes were included in the study. Twelve eyes were determined to have peripheral WWOP; 33 eyes did not have WWOP on examination or color fundus photography. Three common UWFA peripheral patterns were visualized. Eyes with and without WWOP were grouped into one of three patterns. The majority of eyes without WWOP demonstrated UWFA pattern one (69.7%), while those in the WWOP group demonstrated pattern three (50%). The distribution of UWFA patterns is statistically different between those with and without WWOP (P = 0.002). In eyes without WWOP, in patients with no documented systemic microvascular disease (diabetes, hypertension), 71.4% of eyes had UWFA pattern one while 14.3% had both patterns two and three. Conclusion This study is one of the first to specifically evaluate peripheral vascular leakage/staining in eyes with WWOP as well as in eyes without any obvious peripheral chorioretinal disease. We demonstrate that a significant portion of WWOP eyes exhibit peripheral findings on UWFA (pattern one) compared to eyes without WWOP. Importantly, even in eyes that are apparently unremarkable in the periphery on exam and color photography, UWFA can still show peripheral vascular abnormalities. These results warrant further investigation. PMID:23737658
DOE Office of Scientific and Technical Information (OSTI.GOV)
Amstutz, Christoph A., E-mail: christoph.amstutz@usz.ch; Bechrakis, Nikolaos E.; Foerster, Michael H.
2012-03-15
Purpose: External beam proton radiation therapy has been used since 1975 to treat choroidal melanoma. For tumor location determination during proton radiation treatment, surgical tantalum clips are registered with image data. This report introduces the intraoperative application of an opto-electronic navigation system to determine with high precision the position of the tantalum markers and their spatial relationship to the tumor and anatomical landmarks. The application of the technique in the first 4 patients is described. Methods and Materials: A navigated reference base was attached noninvasively to the eye, and a navigated pointer device was used to record the spatial positionmore » of the tantalum markers, the tumor, and anatomical landmarks. Measurement accuracy was assessed on ex vivo porcine eye specimen by repetitive recording of the tantalum marker positions. The method was applied intraoperatively on 4 patients undergoing routine tantalum clip surgery. The spatial position information delivered by the navigation system was compared to the geometric data generated by the EYEPLAN software. Results: In the ex vivo experiments, the maximum repetition error was 0.34 mm. For the intraoperative application, the root mean square error of paired-points matching of the marker positions from the navigation system and from the EYEPLAN software was 0.701-1.25 mm. Conclusions: Navigation systems are a feasible tool for accurate localization of tantalum markers and anatomic landmarks. They can provide additional geometric information, and therefore have the potential to increase the reliability and accuracy of external beam proton radiation therapy for choroidal melanoma.« less
Feng, Guangxue; Yuan, Youyong; Fang, Hu; Zhang, Ruoyu; Xing, Bengang; Zhang, Guanxin; Zhang, Deqing; Liu, Bin
2015-08-11
We report the design and synthesis of a red fluorescent AIE light-up probe for selective recognition, naked-eye detection, and image-guided photodynamic killing of Gram-positive bacteria, including vancomycin-resistant Enterococcus strains.
Choi, Mihyun; Lee, Yong Eun; Whang, Woong-Joo; Yoo, Young-Sik; Na, Kyung-Sun; Joo, Choun-Ki
2016-03-01
To evaluate changes in intraocular pressure (IOP) in recipient and donor eyes during femtosecond laser-assisted keratoplasty (FLAK) and to assess for differences in the diameter of trephinated corneal buttons according to changes in pressure. Twenty porcine whole eyes (recipient model) and 20 porcine-corneoscleral rims (donor model) were prepared, and anterior chamber pressures were measured using a fiberoptic sensing device (Opsens, Quebec, Canada) during the femtosecond laser corneal cutting process. To determine the diameter of corneal buttons, 10 porcine whole eyes (recipient model) and 12 corneoscleral rims (donor model) of each baseline IOP were cut with the femtosecond laser programmed to the following pattern: "vertical side cut"; 1200 μm (depth), 8 mm (diameter). Digital photographs were obtained using microscopy and subsequently analyzed. The IOP (mean ± SD) for the recipient model was 10.2 (±0.9) mm Hg at baseline and ranged from 96.6 (±4.5) to ∼138.4 (±3.8) mm Hg during the corneal cutting process. This shows that the maximum IOP during FLAK increased 13.5 times compared with baseline. In the donor model, the mean pressure elevation from baseline artificial anterior chamber (AAC) pressure to corneal cutting was 15.8 (±5.4) mm Hg. This showed a positive correlation with baseline IOP [correlation coefficient (CC) = 0.827, P = 0.006]. As the baseline IOP in the recipient eye increased, trephinated corneal button size was reduced by up to 3.9% in diameter (CC = -0.945, P = 0.015). In addition, in donor eyes, the diameter was decreased by up to 11.7% as the baseline AAC pressure increased (CC = -0.934, P = 0.006). During the FLAK procedure, the IOP increases in both recipient and donor eyes. The diameter of the trephinated donor and recipient corneal buttons was decreased as the initial baseline IOP increased. Ophthalmic surgeons can determine the AAC pressure based on the baseline IOP in the recipient patient.
Fricker, Georgina V; Smith, Kerry; Gould, David J
2016-09-01
To determine the prevalence of pectinate ligament dysplasia (PLD) in UK Leonbergers and identify cases affected by glaucoma. Also, to define the spectrum of pectinate ligament (PL) appearance in this breed and determine whether gonioscopic monitoring should be recommended. Data were compiled from 78 prospective gonioscopy examinations performed by one author (GF) and retrospective analysis of 233 UK eye scheme certificates (2009-2014). Clinical cases of glaucoma in Leonbergers diagnosed by UK veterinary ophthalmologists, where gonioscopy of the fellow eyes or histology of affected eyes had been performed, were also reviewed. In the prospective study, intraocular pressure was recorded prior to gonioscopy using a rebound tonometer. Gonioscopy was performed using a slit-lamp biomicroscope with a Koeppe goniolens. PLD was categorized according to the percentage of the iridocorneal drainage angle affected (grade 0 = <25% affected; grade 1 = 25-50% affected; grade 2 = 51-75% affected; and grade 3 = >75% affected), and the degree of narrowing of the angle was noted. Of 78 dogs examined prospectively, 64/78 (82%) were grade 0, 7/78 (9%) were grade 1, 3/78 (4%) were grade 2, and 4/78 (5%) were grade 3. A large phenotypic variation was observed. Spearman's rank correlation showed a positive correlation between age and severity of PLD (P < 0.0055). 52 (22%) of Leonbergers examined under the UK eye scheme 2009-2014 were affected by PLD. Five clinical cases of glaucoma were reviewed where gonioscopy had been performed and one where histology was performed. All individuals had grade 3 PLD with gonioscopy of the contralateral eye or severe goniodysgenesis with histological sections of the affected eye. This survey suggests the prevalence of PLD is sufficient to justify ongoing screening of Leonbergers. © 2015 American College of Veterinary Ophthalmologists.
NASA Astrophysics Data System (ADS)
Volpe, Peter A.
This thesis presents analytical models, finite element models and experimental data to investigate the response of the human eye to loads that can be experienced when in a non-supine sleeping position. The hypothesis being investigated is that non-supine sleeping positions can lead to stress, strain and deformation of the eye as well as changes in intraocular pressure (IOP) that may exacerbate vision loss in individuals who have glaucoma. To investigate the quasi-static changes in stress and internal pressure, a Fluid-Structure Interaction simulation was performed on an axisymmetrical model of an eye. Common Aerospace Engineering methods for analyzing pressure vessels and hyperelastic structural walls are applied to developing a suitable model. The quasi-static pressure increase was used in an iterative code to analyze changes in IOP over time.
Dry eyes and AIs: If you don't ask you won't find out.
Inglis, Holly; Boyle, Frances M; Friedlander, Michael L; Watson, Stephanie L
2015-12-01
Our objective was to investigate the hypothesis that women on adjuvant aromatase inhibitors (AIs) for treatment of breast cancer have a higher prevalence of dry eye syndrome (DES) compared with controls. Exposure and control groups were recruited. A cross sectional questionnaire-based study was performed. Demographic data and medical histories were collected. The presence of dry eye syndrome was determined by the ocular surface disease index (OSDI). The Functional Assessment of Cancer Treatment - Endocrine Subscale (FACT-ES) was performed to investigate correlations with other side effects of AIs. 93 exposure group and 100 control group questionnaires were included. The groups were similar in all demographic variables. The prevalence of dry eye syndrome was 35% (exposure) and 18% (control) (p < 0.01, OR 2.5). AIs were the only factor associated with dry eyes. The OSDI score was negatively correlated with the total FACT-ES score and positively correlated with duration of treatment. Our study is the first to use a validated questionnaire to assess for DES in this population. DES is significantly more prevalent in women on AIs compared with controls. This is a newly emerging, and easily treated side effect of AIs. Self-reporting of dry eye symptoms underestimates the prevalence of DES with AIs. We recommend routine screening of patients on AIs with the OSDI with the aim of improving patient quality of life and possibly adherence. Copyright © 2015 Elsevier Ltd. All rights reserved.
Gosling, Allyson A; Kiland, Julie A; Rutkowski, Lauren E; Hoefs, Adam; Ellinwood, N Matthew; McLellan, Gillian J
2016-01-01
Objective to determine the effect of topical corticosteroid (CCS) therapy on intraocular pressure (IOP) in normal cats and cats with primary feline congenital glaucoma (FCG). Animals studied 5 normal and 11 FCG cats were studied in 2 cohorts. Procedures IOP was measured by a single, masked observer, once daily 3–5 days/week throughout the course of CCS treatment and for up to 11 days after treatment discontinuation. One eye per cat was randomly assigned for treatment twice daily with CCS; Balanced salt solution (BSS) applied to the contralateral eye, served as a control. Differences between eyes and between weeks of the study period were calculated for each cat. A positive response to CCS was defined as a consistent >15% or >25% higher IOP in the treated relative to control eye in normal and FCG cats, respectively. Results 8/11 FCG cats responded to topical CCS after 1–5 weeks of treatment with an increase in IOP relative to the untreated eye (maximum IOP discrepancy of 56 mmHg). 2/5 normal cats responded to topical CCS with appreciable but clinically unimportant increase in IOP in the treated eye (maximum IOP discrepancy of 6.4 mmHg). Conclusions our data indicate that the incidence of steroid induced IOP elevation in cats is lower than previously published feline studies suggest. Cats with pre-existing compromise in aqueous humor outflow may show a greater, clinically relevant response to topical CCS than normal cats. PMID:26876736
[Reliability of static posturography in elderly persons].
Bauer, C M; Gröger, I; Rupprecht, R; Tibesku, C O; Gassmann, K G
2010-08-01
Static posturography is used to quantify body sway. It is used to assess the balance of elderly persons who are prone to falls. There is still no general opinion concerning the reliability of force platform measurements. The aim of this study was to test the reliability of force platform parameters when measuring elderly persons. The reliability of 11 force platform parameters was tested measuring 30 elderly persons. The following parameters were calculated: mean speed of center of pressure displacement in mm/s, length of sway in mm, sway area in mm(2), amplitudes of center of pressure movement, the axis of oscillation in degrees and the person's angles of inclination in degrees. Three measurements were taken on the same day, with a resting period of 2 min. Four different test conditions were used: normal standing and narrow stand with eyes open and eyes closed, respectively. Reliability was determined by using intraclass correlation coefficients. Six parameters had excellent reliability with a correlation coefficient of >0.9: mean speed of center of pressure movement during narrow stand, area of sway during narrow stand, length of sway during normal and narrow stand, and the angle of inclination in the sagittal plane during normal stand and narrow stand. The condition "narrow stand eyes closed" proved to be the most reliable test position. Six parameters proved to have excellent reliability and are recommended to be used in further investigations. Narrow stand with eyes closed should be used as the test position. The tested protocol proved to be reliable. Whether these parameters can be used to predict falls in elderly persons remains to be investigated.
Predictive encoding of moving target trajectory by neurons in the parabigeminal nucleus
Ma, Rui; Cui, He; Lee, Sang-Hun; Anastasio, Thomas J.
2013-01-01
Intercepting momentarily invisible moving objects requires internally generated estimations of target trajectory. We demonstrate here that the parabigeminal nucleus (PBN) encodes such estimations, combining sensory representations of target location, extrapolated positions of briefly obscured targets, and eye position information. Cui and Malpeli (Cui H, Malpeli JG. J Neurophysiol 89: 3128–3142, 2003) reported that PBN activity for continuously visible tracked targets is determined by retinotopic target position. Here we show that when cats tracked moving, blinking targets the relationship between activity and target position was similar for ON and OFF phases (400 ms for each phase). The dynamic range of activity evoked by virtual targets was 94% of that of real targets for the first 200 ms after target offset and 64% for the next 200 ms. Activity peaked at about the same best target position for both real and virtual targets. PBN encoding of target position takes into account changes in eye position resulting from saccades, even without visual feedback. Since PBN response fields are retinotopically organized, our results suggest that activity foci associated with real and virtual targets at a given target position lie in the same physical location in the PBN, i.e., a retinotopic as well as a rate encoding of virtual-target position. We also confirm that PBN activity is specific to the intended target of a saccade and is predictive of which target will be chosen if two are offered. A Bayesian predictor-corrector model is presented that conceptually explains the differences in the dynamic ranges of PBN neuronal activity evoked during tracking of real and virtual targets. PMID:23365185
Delgado, S; Velazco, J; Delgado Pelayo, R M; Ruiz-Quintero, N
2016-07-01
To determine the correlation of higher order aberrations in anterior corneal surface and degree of keratoconus measured with a Scheimpflug camera. A descriptive, cross-sectional study was conducted on 152 eyes (both eyes of each patient) of patients with keratoconus, from January 2009 to April 2014. An examination was performed on the corneal aberrometry in the anterior corneal surface, and topographic mapping (by Amsler and Muckenhirn classification) was used to determine the degree of keratoconus. The correlation between high-order aberrations in anterior corneal surface and the degree of keratoconus was determined. Coma aberration significantly correlated with keratoconus severity (r=.60, P<.01), as well as with the high order aberration (r=.61, P<.01). Trefoil and keratoconus were weakly correlated (r=.34, P<.01). Higher order aberrations in anterior corneal surface were positively correlated with the degree of keratoconus in a similar way to the entire optical system. Copyright © 2016 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.
Lev-Ari, Tidhar; Lustig, Avichai; Ketter-Katz, Hadas; Baydach, Yossi; Katzir, Gadi
2016-08-01
A chameleon (Chamaeleo chamaeleon) on a perch responds to a nearby threat by moving to the side of the perch opposite the threat, while bilaterally compressing its abdomen, thus minimizing its exposure to the threat. If the threat moves, the chameleon pivots around the perch to maintain its hidden position. How precise is the body rotation and what are the patterns of eye movement during avoidance? Just-hatched chameleons, placed on a vertical perch, on the side roughly opposite to a visual threat, adjusted their position to precisely opposite the threat. If the threat were moved on a horizontal arc at angular velocities of up to 85°/s, the chameleons co-rotated smoothly so that (1) the angle of the sagittal plane of the head relative to the threat and (2) the direction of monocular gaze, were positively and significantly correlated with threat angular position. Eye movements were role-dependent: the eye toward which the threat moved maintained a stable gaze on it, while the contralateral eye scanned the surroundings. This is the first description, to our knowledge, of such a response in a non-flying terrestrial vertebrate, and it is discussed in terms of possible underlying control systems.
Benavente-Perez, Alexandra; Nour, Ann; Troilo, David
2012-09-21
We evaluated the effect of imposing negative and positive defocus simultaneously on the eye growth and refractive state of the common marmoset, a New World primate that compensates for either negative and positive defocus when they are imposed individually. Ten marmosets were reared with multizone contact lenses of alternating powers (-5 diopters [D]/+5 D), 50:50 ratio for average pupil of 2.80 mm over the right eye (experimental) and plano over the fellow eye (control) from 10 to 12 weeks. The effects on refraction (mean spherical equivalent [MSE]) and vitreous chamber depth (VC) were measured and compared to untreated, and -5 D and +5 D single vision contact lens-reared marmosets. Over the course of the treatment, pupil diameters ranged from 2.26 to 2.76 mm, leading to 1.5 times greater exposure to negative than positive power zones. Despite this, at different intervals during treatment, treated eyes were on average relatively more hyperopic and smaller than controls (experimental-control [exp-con] mean MSE ± SE +1.44 ± 0.45 D, mean VC ± SE -0.05 ± 0.02 mm) and the effects were similar to those in marmosets raised on +5 D single vision contact lenses (exp-con mean MSE ± SE +1.62 ± 0.44 D. mean VC ± SE -0.06 ± 0.03 mm). Six weeks into treatment, the interocular growth rates in multizone animals were already lower than in -5 D-treated animals (multizone -1.0 ± 0.1 μm/day, -5 D +2.1 ± 0.9 μm/day) and did not change significantly throughout treatment. Imposing hyperopic and myopic defocus simultaneously using concentric contact lenses resulted in relatively smaller and less myopic eyes, despite treated eyes being exposed to a greater percentage of negative defocus. Exposing the retina to combined dioptric powers with multifocal lenses that include positive defocus might be an effective treatment to control myopia development or progression.
Temporal Dynamics of Ocular Position Dependence of the Initial Human Vestibulo-ocular Reflex
Crane, Benjamin T.; Tian, Junru; Demer, Joseph L.
2007-01-01
Purpose While an ideal vestibulo-ocular reflex (VOR) generates ocular rotations compensatory for head motion, during visually guided movements, Listing’s Law (LL) constrains the eye to rotational axes lying in Listing’s Plane (LP). The present study was conducted to explore the recent proposal that the VOR’s rotational axis is not collinear with the head’s, but rather follows a time-dependent strategy intermediate between LL and an ideal VOR. Methods Binocular LPs were defined during visual fixation in eight normal humans. The VOR was evoked by a highly repeatable transient whole-body yaw rotation in darkness at a peak acceleration of 2800 deg/s2. Immediately before rotation, subjects regarded targets 15 or 500 cm distant located at eye level, 20° up, or 20° down. Eye and head responses were compared with LL predictions in the position and velocity domains. Results LP orientation varied both among subjects and between individual subject’s eyes, and rotated temporally with convergence by 5 ± 5° (±SEM). In the position domain, the eye compensated for head displacement even when the head rotated out of LP. Even within the first 20 ms from onset of head rotation, the ocular velocity axis tilted relative to the head axis by 30% ± 8% of vertical gaze position. Saccades increased this tilt. Regardless of vertical gaze position, the ocular rotation axis tilted backward 4° farther in abduction than in adduction. There was also a binocular vertical eye velocity transient and lateral tilt of the ocular axis. Conclusions These disconjugate, short-latency axis perturbations appear intrinsic to the VOR and may have neural or mechanical origins. PMID:16565376
Relationship between relative lens position and appositional closure in eyes with narrow angles.
Otori, Yasumasa; Tomita, Yuki; Hamamoto, Ayumi; Fukui, Kanae; Usui, Shinichi; Tatebayashi, Misako
2011-03-01
To investigate the relationship between relative lens position (RLP) and appositional closure in eyes with narrow angles. Ultrasound biomicroscopy (UBM) was used to measure anterior chamber depth (ACD) and lens thickness (LT), and the IOLMaster to measure axial length (AL). The number of quadrants with appositional closure was assessed by UBM under dark conditions. The RLP was calculated thus: RLP = 10 × (ACD + 0.5 LT) /AL. This study comprised 30 consecutive patients (30 eyes) with narrow-angle eyes defined as Shaffer grade 2 or lower and without peripheral anterior synechiae (24 women, 6 men; mean age ± SD, 67.3 ± 10.4 years; range, 42-87 years). Under dark conditions, 66.7% of the eyes with narrow angles showed appositional closure in at least one quadrant. Of the various ocular biometric parameters, only the RLP significantly decreased with appositional closure in at least one quadrant (P = 0.005). A decrease in the RLP can be predictive of appositional closure for narrow-angle eyes under dark conditions.
Air Bubble-Induced High Intraocular Pressure After Descemet Membrane Endothelial Keratoplasty.
Röck, Daniel; Bartz-Schmidt, Karl Ulrich; Röck, Tobias; Yoeruek, Efdal
2016-08-01
To investigate the incidence and risk factors of pupillary block caused by an air bubble in the anterior chamber in the early postoperative period after Descemet membrane endothelial keratoplasty (DMEK). A retrospective review was conducted in 306 eyes that underwent DMEK from September 2009 through October 2014 at the Tübingen Eye Hospital. Intraocular pressure (IOP) elevation was defined as a spike above 30 mm Hg. In the first 190 eyes, an intraoperative peripheral iridectomy was performed at the 12-o'clock position and in the other 116 eyes at the 6-o'clock position. If possible, reasons for IOP elevation were identified. For all eyes, preoperative and postoperative slit-lamp examinations and IOP measurements were performed. Overall, 30 eyes (9.8%) showed a postoperative IOP elevation within the first postoperative day. The incidence of IOP elevation was 13.9% (5/36) in the triple DMEK group, and 2 of 5 phakic eyes (40%) developed an air bubble-induced IOP elevation. All eyes presented with a de novo IOP elevation, associated in 25 patients with pupillary block from air anterior to iris and in 5 patients with angle closure from air migration posterior to the iris. All of them had an iridectomy at the 12-o'clock position. A postoperative pupillary block with IOP elevation caused by the residual intraoperative air bubble may be an important complication that could be avoided by close and frequent observations, especially in the first postoperative hours and by an inferior peripheral iridectomy and an air bubble with a volume of ≤80% of the anterior chamber.
Eye-gaze determination of user intent at the computer interface
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goldberg, J.H.; Schryver, J.C.
1993-12-31
Determination of user intent at the computer interface through eye-gaze monitoring can significantly aid applications for the disabled, as well as telerobotics and process control interfaces. Whereas current eye-gaze control applications are limited to object selection and x/y gazepoint tracking, a methodology was developed here to discriminate a more abstract interface operation: zooming-in or out. This methodology first collects samples of eve-gaze location looking at controlled stimuli, at 30 Hz, just prior to a user`s decision to zoom. The sample is broken into data frames, or temporal snapshots. Within a data frame, all spatial samples are connected into a minimummore » spanning tree, then clustered, according to user defined parameters. Each cluster is mapped to one in the prior data frame, and statistics are computed from each cluster. These characteristics include cluster size, position, and pupil size. A multiple discriminant analysis uses these statistics both within and between data frames to formulate optimal rules for assigning the observations into zooming, zoom-out, or no zoom conditions. The statistical procedure effectively generates heuristics for future assignments, based upon these variables. Future work will enhance the accuracy and precision of the modeling technique, and will empirically test users in controlled experiments.« less
Localized Glaucomatous Change Detection within the Proper Orthogonal Decomposition Framework
Balasubramanian, Madhusudhanan; Kriegman, David J.; Bowd, Christopher; Holst, Michael; Weinreb, Robert N.; Sample, Pamela A.; Zangwill, Linda M.
2012-01-01
Purpose. To detect localized glaucomatous structural changes using proper orthogonal decomposition (POD) framework with false-positive control that minimizes confirmatory follow-ups, and to compare the results to topographic change analysis (TCA). Methods. We included 167 participants (246 eyes) with ≥4 Heidelberg Retina Tomograph (HRT)-II exams from the Diagnostic Innovations in Glaucoma Study; 36 eyes progressed by stereo-photographs or visual fields. All other patient eyes (n = 210) were non-progressing. Specificities were evaluated using 21 normal eyes. Significance of change at each HRT superpixel between each follow-up and its nearest baseline (obtained using POD) was estimated using mixed-effects ANOVA. Locations with significant reduction in retinal height (red pixels) were determined using Bonferroni, Lehmann-Romano k-family-wise error rate (k-FWER), and Benjamini-Hochberg false discovery rate (FDR) type I error control procedures. Observed positive rate (OPR) in each follow-up was calculated as a ratio of number of red pixels within disk to disk size. Progression by POD was defined as one or more follow-ups with OPR greater than the anticipated false-positive rate. TCA was evaluated using the recently proposed liberal, moderate, and conservative progression criteria. Results. Sensitivity in progressors, specificity in normals, and specificity in non-progressors, respectively, were POD-Bonferroni = 100%, 0%, and 0%; POD k-FWER = 78%, 86%, and 43%; POD-FDR = 78%, 86%, and 43%; POD k-FWER with retinal height change ≥50 μm = 61%, 95%, and 60%; TCA-liberal = 86%, 62%, and 21%; TCA-moderate = 53%, 100%, and 70%; and TCA-conservative = 17%, 100%, and 84%. Conclusions. With a stronger control of type I errors, k-FWER in POD framework minimized confirmatory follow-ups while providing diagnostic accuracy comparable to TCA. Thus, POD with k-FWER shows promise to reduce the number of confirmatory follow-ups required for clinical care and studies evaluating new glaucoma treatments. (ClinicalTrials.gov number, NCT00221897.) PMID:22491406
Tender, Gabriel C; Walbridge, Stuart; Olah, Zoltan; Karai, Laszlo; Iadarola, Michael; Oldfield, Edward H; Lonser, Russell R
2005-03-01
Neuropathic pain is mediated by nociceptive neurons that selectively express the vanilloid receptor 1 (VR1). Resiniferatoxin (RTX) is an excitotoxic VR1 agonist that causes destruction of VR1-positive neurons. To determine whether RTX can be used to ablate VR1-positive neurons selectively and to eliminate hyperalgesia and neurogenic inflammation without affecting tactile sensation and motor function, the authors infused it unilaterally into the trigeminal ganglia in Rhesus monkeys. Either RTX (three animals) or vehicle (one animal) was directly infused (20 microl) into the right trigeminal ganglion in Rhesus monkeys. Animals were tested postoperatively at 1, 4, and 7 weeks thereafter for touch and pain perception in the trigeminal distribution (application of saline and capsaicin to the cornea). The number of eye blinks, eye wipes, and duration of squinting were recorded. Neurogenic inflammation was tested using capsaicin cream. Animals were killed 4 (one monkey) and 12 (three monkeys) weeks postinfusion. Histological and immunohistochemical analyses were performed. Throughout the duration of the study, response to high-intensity pain stimulation (capsaicin) was selectively and significantly reduced (p < 0.001, RTX-treated compared with vehicle-treated eye [mean +/- standard deviation]): blinks, 25.7 +/- 4.4 compared with 106.6 +/- 20.8; eye wipes, 1.4 +/- 0.8 compared with 19.3 +/- 2.5; and squinting, 1.4 +/- 0.6 seconds compared with 11.4 +/- 1.6 seconds. Normal response to sensation was maintained. Animals showed no neurological deficit or sign of toxicity. Neurogenic inflammation was blocked on the RTX-treated side. Immunohistochemical analysis of the RTX-treated ganglia showed selective elimination of VR1-positive neurons. Nociceptive neurons can be selectively ablated by intraganglionic RTX infusion, resulting in the elimination of high-intensity pain perception and neurogenic inflammation while maintaining normal sensation and motor function. Analysis of these findings indicated that intraganglionic RTX infusion may provide a new treatment for pain syndromes such as trigeminal neuralgia as well as others.
Migliaccio, Americo A; Della Santina, Charles C; Carey, John P; Minor, Lloyd B; Zee, David S
2006-08-01
We examined how the gain of the torsional vestibulo-ocular reflex (VOR) (defined as the instantaneous eye velocity divided by inverted head velocity) in normal humans is affected by eye position, target distance, and the plane of head rotation. In six normal subjects we measured three-dimensional (3D) eye and head rotation axes using scleral search coils, and 6D head position using a magnetic angular and linear position measurement device, during low-amplitude (approximately 20 degrees ), high-velocity (approximately 200 degrees/s), high-acceleration (approximately 4000 degrees /s2) rapid head rotations or 'impulses.' Head impulses were imposed manually and delivered in five planes: yaw (horizontal canal plane), pitch, roll, left anterior-right posterior canal plane (LARP), and right anterior-left posterior canal plane (RALP). Subjects were instructed to fix on one of six targets at eye level. Targets were either straight-ahead, 20 degrees left or 20 degrees right from midline, at distance 15 or 124 cm from the subject. Two subjects also looked at more eccentric targets, 30 degrees left or 30 degrees right from midline. We found that the vertical and horizontal VOR gains increased with the proximity of the target to the subject. Previous studies suggest that the torsional VOR gain should decrease with target proximity. We found, however, that the torsional VOR gain did not change for all planes of head rotation and for both target distances. We also found a dynamic misalignment of the vertical positions of the eyes during the torsional VOR, which was greatest during near viewing with symmetric convergence. This dynamic vertical skew during the torsional VOR arises, in part, because when the eyes are converged, the optical axes are not parallel to the naso-occipital axes around which the eyes are rotating. In five of six subjects, the average skew ranged 0.9 degrees -2.9 degrees and was reduced to <0.4 degrees by a 'torsional' quick-phase (around the naso-occipital axis) occurring <110 ms after the onset of the impulse. We propose that the torsional quick-phase mechanism during the torsional VOR could serve at least three functions: (1) resetting the retinal meridians closer to their usual orientation in the head, (2) correcting for the 'skew' deviation created by misalignment between the axes around which the eyes are rotating and the line of sight, and (3) taking the eyes back toward Listing's plane.
NASA Technical Reports Server (NTRS)
Angelaki, Dora E.
2003-01-01
Previous studies have reported that the translational vestibuloocular reflex (TVOR) follows a three-dimensional (3D) kinematic behavior that is more similar to visually guided eye movements, like pursuit, rather than the rotational VOR (RVOR). Accordingly, TVOR rotation axes tilted with eye position toward an eye-fixed reference frame rather than staying relatively fixed in the head like in the RVOR. This difference arises because, contrary to the RVOR where peripheral image stability is functionally important, the TVOR like pursuit and saccades cares to stabilize images on the fovea. During most natural head and body movements, both VORs are simultaneously activated. In the present study, we have investigated in rhesus monkeys the 3D kinematics of the combined VOR during yaw rotation about eccentric axes. The experiments were motivated by and quantitatively compared with the predictions of two distinct hypotheses. According to the first (fixed-rule) hypothesis, an eye-position-dependent torsion is computed downstream of a site for RVOR/TVOR convergence, and the combined VOR axis would tilt through an angle that is proportional to gaze angle and independent of the relative RVOR/TVOR contributions to the total eye movement. This hypothesis would be consistent with the recently postulated mechanical constraints imposed by extraocular muscle pulleys. According to the second (image-stabilization) hypothesis, an eye-position-dependent torsion is computed separately for the RVOR and the TVOR components, implying a processing that takes place upstream of a site for RVOR/TVOR convergence. The latter hypothesis is based on the functional requirement that the 3D kinematics of the combined VOR should be governed by the need to keep images stable on the fovea with slip on the peripheral retina being dependent on the different functional goals of the two VORs. In contrast to the fixed-rule hypothesis, the data demonstrated a variable eye-position-dependent torsion for the combined VOR that was different for synergistic versus antagonistic RVOR/TVOR interactions. Furthermore, not only were the eye-velocity tilt slopes of the combined VOR as much as 10 times larger than what would be expected based on extraocular muscle pulley location, but also eye velocity during antagonistic RVOR/TVOR combinations often tilted opposite to gaze. These results are qualitatively and quantitatively consistent with the image-stabilization hypothesis, suggesting that the eye-position-dependent torsion is computed separately for the RVOR and the TVOR and that the 3D kinematics of the combined VOR are dependent on functional rather than mechanical constraints.
Intraocular lens power selection and positioning with and without intraoperative aberrometry.
Hatch, Kathryn M; Woodcock, Emily C; Talamo, Jonathan H
2015-04-01
To determine the value of intraoperative aberrometry in cases of toric intraocular lens (IOL) implantation and positioning. In this non-randomized retrospective comparative trial, two groups of eyes underwent cataract extraction with toric IOL implantation: the aberrometry group (n = 37 eyes), where toric IOL power and alignment were determined before surgery with automated keratometry, standard optical biometry, and an online calculator and then refined using intraoperative aberrometry, and the toric calculator group (n = 27 eyes), where IOL selection was performed in a similar manner but without intraoperative aberrometry. The primary outcome measure was mean postoperative residual refractive astigmatism (RRA). Mean RRA measured at follow-up after surgery was 0.46 ± 0.42 and 0.68 ± 0.34 diopters (D) in the aberrometry and toric calculator groups, respectively (P = .0153). A 75% and 57% reduction in cylinder was noted between preoperative keratometric astigmatism and postoperative RRA in the aberrometry and toric calculator groups, respectively (P = .0027). RRA of 0.25 D or less, 0.50 D or less, 0.75 D or less, and 1.00 D or less was seen 38%, 78%, 86%, and 95% of the time, respectively, in the aberrometry group and 22%, 33%, 74%, and 89% of the time, respectively, in the toric calculator group. These data show that the chance of a patient being in a lower postoperative RRA range increased when intraoperative aberrometry was used (P = .0130). Patients undergoing cataract extraction with toric IOL placement aided by intraoperative aberrometry were 2.4 times more likely to have less than 0.50 D of RRA compared to standard methods. Copyright 2015, SLACK Incorporated.
Head and cervical posture in patients with temporomandibular disorders.
Armijo-Olivo, Susan; Rappoport, Karen; Fuentes, Jorge; Gadotti, Inae Caroline; Major, Paul W; Warren, Sharon; Thie, Norman M R; Magee, David J
2011-01-01
To determine whether patients with myogenous or mixed (ie, myogeneous plus arthrogeneous) temporomandibular disorders (TMD) had different head and cervical posture measured through angles commonly used in clinical research settings when compared to healthy individuals. One hundred fifty-four persons participated in this study. Of these, 50 subjects were healthy, 55 subjects had myogenous TMD, and 49 subjects had mixed TMD (ie, arthrogenous plus myogenous TMD). A lateral photograph was taken with the head in the self-balanced position. Four angles were measured in the photographs: (1) Eye-Tragus-Horizontal, (2) Tragus-C7-Horizontal, (3) Pogonion-Tragus-C7, and (4) Tragus-C7-Shoulder. Alcimagen software specially designed to measure angles was used in this study. All of the measurements were performed by a single trained rater, a dental specialist in orthodontics, blinded to each subject's group status. The only angle that reached statistical significance among groups was the Eye-Tragus-Horizontal (F = 3.03, P = .040). Pairwise comparisons determined that a mean difference of 3.3 degrees (95% confidence intervals [CI]: 0.15, 6.41) existed when comparing subjects with myogenous TMD and healthy subjects (P = .036). Postural angles were not significantly related to neck disability, jaw disability, or pain intensity. Intrarater and interrater reliability of the measurements were excellent, with intraclass correlation coefficient (ICC) values ranging between 0.996-0.998. The only statistically significant difference in craniocervical posture between patients with myogenous TMD and healthy subjects was for the Eye-Tragus-Horizontal angle, indicating a more extended position of the head. However, the difference was very small (3.3 degrees) and was judged not to be clinically significant.
Standing balance tests for screening people with vestibular impairments.
Cohen, Helen S; Mulavara, Ajitkumar P; Peters, Brian T; Sangi-Haghpeykar, Haleh; Bloomberg, Jacob J
2014-02-01
To improve the test standards for a version of the Romberg test and to determine whether measuring kinematic variables improved its utility for screening. Healthy controls and patients with benign paroxysmal positional vertigo, postoperative acoustic neuroma resection, and chronic peripheral unilateral weakness were compared. Subjects wore Bluetooth-enabled inertial motion units while standing on the floor or medium-density, compliant foam, with eyes open or closed, with head still or moving in pitch or yaw. Dependent measures were time to perform each test condition, number of head movements made, and kinematic variables. Patients and controls did not differ significantly with eyes open or with eyes closed while on the floor. With eyes closed, on foam, some significant differences were found between patients and controls, especially for subjects older than 59 years. Head movement conditions were more challenging than with the head still. Significantly fewer patients than controls could make enough head movements to obtain kinematic measures. Kinematics indicated that lateral balance control is significantly reduced in these patients compared to controls. Receiver operator characteristics and sensitivity/specificity analyses showed moderately good differences with older subjects. Tests on foam with eyes closed, with head still or moving, may be useful as part of a screening battery for vestibular impairments, especially for older people. 3b. Copyright © 2013 The American Laryngological, Rhinological and Otological Society, Inc.
Galoian, V R
1988-01-01
It is well known that the eye is a phylogenetically stabilized body with rotation properties. The eye has an elastic cover and is filled with uniform fluid. According to the theory of covers and other concepts on the configuration of turning fluid mass we concluded that the eyeball has an elliptic configuration. Classification of the eyeball is here presented with simultaneous studies of the principles of the eye situation. The parallelism between the state and different types of heterophory and orthophory was studied. To determine normal configuration it is necessary to have in mind some principles of achieving advisable correct situation of the eye in orbit. We determined the centre of the eye rotation and showed that it is impossible to situate it out of the geometrical centre of the eyeball. It was pointed out that for adequate perception the rotation centre must be situated on the visual axis. Using the well known theory of floating we experimentally determined that the centre of the eye rotation lies on the level of the floating eye, just on the point of cross of the visual line with the optical axis. It was shown experimentally on the basis of recording the eye movements in the process of eyelid closing that weakening of the eye movements is of gravitational pattern and proceeds under the action of stability forces, which directly indicates the floating state of the eye. For the first time using the model of the floating eye it was possible to show the formation of extraeye vacuum by straining the back wall. This effect can be obtained without any difficulty, if the face is turned down. The role of negative pressure in the formation of the eye ametropy, as well as new conclusions and prognostications about this new model are discussed.
Tokarz-Sawińska, Ewa
2012-01-01
In Part I the problems associated with refraction, accommodation and convergence and their role in proper eye position/visual alignment of the eyes as well as convergent, divergent and vertical alignment of the eyes have been described.
Langeslag-Smith, Miriam A; Vandal, Alain C; Briane, Vincent; Thompson, Benjamin; Anstice, Nicola S
2015-11-27
To assess the accuracy of preschool vision screening in a large, ethnically diverse, urban population in South Auckland, New Zealand. Retrospective longitudinal study. B4 School Check vision screening records (n=5572) were compared with hospital eye department data for children referred from screening due to impaired acuity in one or both eyes who attended a referral appointment (n=556). False positive screens were identified by comparing screening data from the eyes that failed screening with hospital data. Estimation of false negative screening rates relied on data from eyes that passed screening. Data were analysed using logistic regression modelling accounting for the high correlation between results for the two eyes of each child. Positive predictive value of the preschool vision screening programme. Screening produced high numbers of false positive referrals, resulting in poor positive predictive value (PPV=31%, 95% CI 26% to 38%). High estimated negative predictive value (NPV=92%, 95% CI 88% to 95%) suggested most children with a vision disorder were identified at screening. Relaxing the referral criteria for acuity from worse than 6/9 to worse than 6/12 improved PPV without adversely affecting NPV. The B4 School Check generated numerous false positive referrals and consequently had a low PPV. There is scope for reducing costs by altering the visual acuity criterion for referral. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Fuzzy logic-based approach to detecting a passive RFID tag in an outpatient clinic.
Min, Daiki; Yih, Yuehwern
2011-06-01
This study is motivated by the observations on the data collected by radio frequency identification (RFID) readers in a pilot study, which was used to investigate the feasibility of implementing an RFID-based monitoring system in an outpatient eye clinic. The raw RFID data collected from RFID readers contain noise and missing reads, which prevent us from determining the tag location. In this paper, fuzzy logic-based algorithms are proposed to interpret the raw RFID data to extract accurate information. The proposed algorithms determine the location of an RFID tag by evaluating its possibility of presence and absence. To evaluate the performance of the proposed algorithms, numerical experiments are conducted using the data observed in the outpatient eye clinic. Experiments results showed that the proposed algorithms outperform existing static smoothing method in terms of minimizing both false positives and false negatives. Furthermore, the proposed algorithms are applied to a set of simulated data to show the robustness of the proposed algorithms at various levels of RFID reader reliability.
Kurpińska, Małgorzata; Gorczyńska, Ewa; Owoc-Lempach, Joanna; Bernacka, Aleksandra; Misiuk-Hojło, Marta; Chybicka, Alicja
2011-01-01
Dry eye syndrome (DES), also known as keratoconjunctivitis sicca (KCS) is recognized as the most frequent ocular complication after allogeneic stem cell transplantation (allo-SCT). KCS can appear either due to insufficient tear production or excessive tear evaporation, both resulting in tears hyperosmolarity that leads to ocular damage. The evaporation rate and better film stability is determined primarily by the status of the lipid layer. Observation and classification of tear film lipid layer interference patterns in normal and dry eyes in patients after allogeneic stem cell transplantation with a follow-up time of 6 months-5 years (median 26.54 months). Investigation of the relation between the lipid layer interference patterns in normal and dry eyes and the results of other dry eye examinations and complaints. Relation between DES and conditioning regimes, including total body irradiation and high-dose chemotherapy, immunosuppressive drugs, the time after allogeneic stem cell transplantation and chronic graft-versus-host disease. Precorneal tears lipid layer interference patterns, were examined in 114 eyes in treatment group with the Tearscope-plus. Patient with dry eye were identified on the basis of Schirmer test scores and/or tear breakup time, and positive lissamine and/or fluorescein staining. 42 of 114 eyes (36.8%) developed DES after allo-SCT A significant correlation between thickness of lipid layer and BUT, Schirmer test, lissamine green and fluorescein staining was found in the treatment group. A significant association was found between present chronic GVHD and DES in children. DES was not associated with TBI, corticosteroids, immunosuppressive drugs and the time in the present study. Tears lipid layer interference patterns are highly correlated with the diagnosis of DES. Tears lipid layer interference patterns ( noninvasive method), can be used to diagnose early DES in children after allo-SCT. Chronic GVHD play a major role in development of DES. dry eye syndrome, graft versus host disease, stem cell transplantation.
Instrument Display Visual Angles for Conventional Aircraft and the MQ-9 Ground Control Station
NASA Technical Reports Server (NTRS)
Bendrick, Gregg A.; Kamine, Tovy Haber
2008-01-01
Aircraft instrument panels should be designed such that primary displays are in optimal viewing location to minimize pilot perception and response time. Human Factors engineers define three zones (i.e. "cones") of visual location: 1) "Easy Eye Movement" (foveal vision); 2) "Maximum Eye Movement" (peripheral vision with saccades), and 3) "Head Movement" (head movement required). Instrument display visual angles were measured to determine how well conventional aircraft (T-34, T-38, F- 15B, F-16XL, F/A-18A, U-2D, ER-2, King Air, G-III, B-52H, DC-10, B747-SCA) and the MQ-9 ground control station (GCS) complied with these standards, and how they compared with each other. Methods: Selected instrument parameters included: attitude, pitch, bank, power, airspeed, altitude, vertical speed, heading, turn rate, slip/skid, AOA, flight path, latitude, longitude, course, bearing, range and time. Vertical and horizontal visual angles for each component were measured from the pilot s eye position in each system. Results: The vertical visual angles of displays in conventional aircraft lay within the cone of "Easy Eye Movement" for all but three of the parameters measured, and almost all of the horizontal visual angles fell within this range. All conventional vertical and horizontal visual angles lay within the cone of "Maximum Eye Movement". However, most instrument vertical visual angles of the MQ-9 GCS lay outside the cone of "Easy Eye Movement", though all were within the cone of "Maximum Eye Movement". All the horizontal visual angles for the MQ-9 GCS were within the cone of "Easy Eye Movement". Discussion: Most instrument displays in conventional aircraft lay within the cone of "Easy Eye Movement", though mission-critical instruments sometimes displaced less important instruments outside this area. Many of the MQ-9 GCS systems lay outside this area. Specific training for MQ-9 pilots may be needed to avoid increased response time and potential error during flight.
Single neural code for blur in subjects with different interocular optical blur orientation
Radhakrishnan, Aiswaryah; Sawides, Lucie; Dorronsoro, Carlos; Peli, Eli; Marcos, Susana
2015-01-01
The ability of the visual system to compensate for differences in blur orientation between eyes is not well understood. We measured the orientation of the internal blur code in both eyes of the same subject monocularly by presenting pairs of images blurred with real ocular point spread functions (PSFs) of similar blur magnitude but varying in orientations. Subjects assigned a level of confidence to their selection of the best perceived image in each pair. Using a classification-images–inspired paradigm and applying a reverse correlation technique, a classification map was obtained from the weighted averages of the PSFs, representing the internal blur code. Positive and negative neural PSFs were obtained from the classification map, representing the neural blur for best and worse perceived blur, respectively. The neural PSF was found to be highly correlated in both eyes, even for eyes with different ocular PSF orientations (rPos = 0.95; rNeg = 0.99; p < 0.001). We found that in subjects with similar and with different ocular PSF orientations between eyes, the orientation of the positive neural PSF was closer to the orientation of the ocular PSF of the eye with the better optical quality (average difference was ∼10°), while the orientation of the positive and negative neural PSFs tended to be orthogonal. These results suggest a single internal code for blur with orientation driven by the orientation of the optical blur of the eye with better optical quality. PMID:26114678
Clinical presentation of familial exudative vitreoretinopathy.
Ranchod, Tushar M; Ho, Lawrence Y; Drenser, Kimberly A; Capone, Antonio; Trese, Michael T
2011-10-01
To describe the clinical characteristics, staging and presentation of patients with familial exudative vitreoretinopathy (FEVR) in our clinical practice over the last 25 years. Case series, retrospective review. We included 273 eyes of 145 patients. Data collected from charts included gender, gestational age at birth, birthweight, age at presentation, referring diagnosis, family history, prior ocular surgery, and clinical presentation in each eye. Eyes with invasive posterior segment procedures before initial presentation were excluded. Demographics on presentation and clinical staging. Patients were slightly male predominant (57%) with a mean birthweight of 2.80 kg (range, 740 g-4.76 kg), mean gestational age of 37.8 weeks (range, 25-42), and mean age at presentation of almost 6 years (range, <1 month-49 years). A positive family history of FEVR was obtained in 18% of patients. A positive family history for ocular disease consistent with but not diagnosed as FEVR was obtained in an additional 19%. Stage 1 FEVR was identified in 45 eyes, stage 2 in 33 eyes, stage 3 in 42 eyes, stage 4 in 89 eyes, and stage 5 in 44 eyes. Radial retinal folds were seen in 77 eyes, 64 of which were temporal or inferotemporal in location. The FEVR patient population is remarkable for the wide range of age at presentation, gestational age, and birthweight. Although a positive family history on presentation may support the diagnosis of FEVR, a negative family history is of little help. The majority of retinal folds extended radially in the temporal quadrants, but radial folds were seen in almost all quadrants. Fellow eyes demonstrated a wide variation in symmetry. The presentation of FEVR may mimic the presentation of other pediatric and adult vitreoretinal disorders, and careful examination is often crucial in making the diagnosis of FEVR. The authors have no proprietary or commercial interest in any of the materials discussed in this article. Copyright © 2011 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Pettorossi, V E; Petrosini, L
1984-12-17
In intact guinea pigs a passive horizontal rotation of the body about the fixed head induces compensatory ocular movements (cervico-ocular reflex). When the static neck deviation is maintained, a significant ocular displacement is observed. In acutely hemilabyrinthectomized animals, static body deviation towards the lesion side tonically alters eye nystagmus. It affects slow phase eye velocity and quick phase amplitude and frequency causing the eye to reach a less eccentric orbital position. Apart from such immediate influences, a plastic effect on eye nystagmus abatement is induced. In the animals restrained with no body-on-head deviation, abatement of nystagmus is delayed with respect to the animals restrained with 35 degrees body deviation towards the lesion side. Thus the head position signal is not only a contributing factor for the correction of postural deficits but also influences the time course of the ocular balancing process following unilateral vestibular damage.
Payne, Hannah L
2017-01-01
Eye movements provide insights about a wide range of brain functions, from sensorimotor integration to cognition; hence, the measurement of eye movements is an important tool in neuroscience research. We describe a method, based on magnetic sensing, for measuring eye movements in head-fixed and freely moving mice. A small magnet was surgically implanted on the eye, and changes in the magnet angle as the eye rotated were detected by a magnetic field sensor. Systematic testing demonstrated high resolution measurements of eye position of <0.1°. Magnetic eye tracking offers several advantages over the well-established eye coil and video-oculography methods. Most notably, it provides the first method for reliable, high-resolution measurement of eye movements in freely moving mice, revealing increased eye movements and altered binocular coordination compared to head-fixed mice. Overall, magnetic eye tracking provides a lightweight, inexpensive, easily implemented, and high-resolution method suitable for a wide range of applications. PMID:28872455
Does conspicuity enhance distraction? Saliency and eye landing position when searching for objects.
Foulsham, Tom; Underwood, Geoffrey
2009-06-01
While visual saliency may sometimes capture attention, the guidance of eye movements in search is often dominated by knowledge of the target. How is the search for an object influenced by the saliency of an adjacent distractor? Participants searched for a target amongst an array of objects, with distractor saliency having an effect on response time and on the speed at which targets were found. Saliency did not predict the order in which objects in target-absent trials were fixated. The within-target landing position was distributed around a modal position close to the centre of the object. Saliency did not affect this position, the latency of the initial saccade, or the likelihood of the distractor being fixated, suggesting that saliency affects the allocation of covert attention and not just eye movements.
Internal structure changes of eyelash induced by eye makeup.
Fukami, Ken-Ichi; Inoue, Takafumi; Kawai, Tomomitsu; Takeuchi, Akihisa; Uesugi, Kentaro; Suzuki, Yoshio
2014-01-01
To investigate how eye makeup affects eyelash structure, internal structure of eyelashes were observed with a scanning X-ray microscopic tomography system using synchrotron radiation light source. Eyelash samples were obtained from 36 Japanese women aged 20-70 years and whose use of eye makeup differed. Reconstructed cross-sectional images showed that the structure of the eyelash closely resembled that of scalp hair. The eyelash structure is changed by use of eye makeup. There was a positive correlation between the frequency of mascara use and the degree of cracking in cuticle. The positive correlation was also found between the frequency of mascara use and the porosity of the cortex. By contrast, the use of eyelash curler did not affect the eyelash structure with statistical significance.
Determinants of Utilization of Eye Care Services in a Rural Adult Population of a Developing Country
Olusanya, Bolutife A.; Ashaye, Adeyinka O.; Owoaje, Eme T.; Baiyeroju, Aderonke M.; Ajayi, Benedictus G.
2016-01-01
Purpose: To describe the factors that determine the utilization of eye care services in a rural community in South-Western Nigeria. Methods: A descriptive cross-sectional survey using a multistage sampling technique was conducted. The main outcome measure was self-reported previous consultation of an orthodox medical facility for eye care. Results: The study sample included 643 participants. Only 122 (19%) respondents had previously visited orthodox facilities in search of eye care and 24% of those with presenting visual acuity <6/18 had sought eye care. Characteristics associated with previous utilization of eye care services were age of =70 years (odds ratio [OR] ≥ 1.7, P = 0.02); male gender (OR = 1.5, P = 0.04); literacy (OR = 1.7, P = 0.007); and residing close to an eye care facility (OR = 2.8, P < 0.001). Blind respondents were three times more likely to seek eye care (P < 0.001). Regression analysis revealed that factors associated with increased likelihood of utilization of eye care services included age ≥70 years; literacy; residence close to an eye facility; being diabetic or hypertensive; history of ocular symptoms, and blindness. Conclusions: These findings suggest that a significant proportion (75%) of adults in the study area are not utilizing eye care services and that blindness is an important determinant of utilization of eye care services. Health education and awareness campaigns about the importance and benefits of seeking eye care early, and the provision of community-based eye care programs are essential to boost the uptake of eye care services in this community as well as other rural areas of West Africa. PMID:26957847
Immediate effect of intravitreal injection of bevacizumab on intraocular pressure
Lemos-Reis, Ricardo; Moreira-Gonçalves, Nuno; Melo, António B; Carneiro, Ângela M; Falcão-Reis, Fernando M
2014-01-01
Purpose To investigate the immediate effect of intravitreal injection of bevacizumab on intraocular pressure (IOP). Methods This was a prospective and nonrandomized study. A total of 291 eyes with macular edema or active choroidal neovascularization were submitted to a single 1.25 mg (0.05 mL) bevacizumab intravitreal injection. Intraocular pressure was measured with an Icare® tonometer immediately before and after injection in a seated position. The presence of subconjunctival reflux was recorded. The fellow eye served as the control. Results Mean preoperative IOP was 18.0±5.9 mmHg in the treated eye versus 16.9±6.0 mmHg in the fellow eye. Mean postoperative IOP was 42.1±14.5 mmHg in the treated eye versus 17.5±6.0 mmHg in the fellow eye. The IOP variation was statistically significant in both cases and controls (P<0.001 and P=0.003, respectively), and this increase was higher in cases than in controls (P<0.001). Postoperative IOPs higher than 50 mmHg were achieved in 32.0% of the eyes. Subconjunctival reflux was present in 21.3% and determined a lower IOP rise (P<0.001). Tested variables (glaucoma, phakic status, and sex) did not have a statistically significant effect on IOP rise or subconjunctival reflux. Conclusion IOP increases with intravitreal bevacizumab injection, reaching 50 mmHg or more in about one third of patients. A higher IOP is expected if no subconjunctival reflux occurs. The baseline IOP does not influence the incidence of subconjunctival reflux. The clinical relevance of these facts has yet to be clarified. PMID:25092962
Kernt, Marcus; Hadi, Indrawati; Pinter, Florian; Seidensticker, Florian; Hirneiss, Christoph; Haritoglou, Christos; Kampik, Anselm; Ulbig, Michael W.; Neubauer, Aljoscha S.
2012-01-01
OBJECTIVE To compare the diagnostic properties of a nonmydriatic 200° ultra-widefield scanning laser ophthalmoscope (SLO) versus mydriatic Early Treatment of Diabetic Retinopathy Study (ETDRS) 7-field photography for diabetic retinopathy (DR) screening. RESEARCH DESIGN AND METHODS A consecutive series of 212 eyes of 141 patients with different levels of DR were examined. Grading of DR and clinically significant macular edema (CSME) from mydriatic ETDRS 7-field stereo photography was compared with grading obtained by Optomap Panoramic 200 SLO images. All SLO scans were performed through an undilated pupil, and no additional clinical information was used for evaluation of all images by the two independent, masked, expert graders. RESULTS Twenty-two eyes from ETDRS 7-field photography and 12 eyes from Optomap were not gradable by at least one grader because of poor image quality. A total of 144 eyes were analyzed regarding DR level and 155 eyes regarding CSME. For ETDRS 7-field photography, 22 eyes (18 for grader 2) had no or mild DR (ETDRS levels ≤ 20) and 117 eyes (111 for grader 2) had no CSME. A highly substantial agreement between both Optomap DR and CSME grading and ETDRS 7-field photography existed with κ = 0.79 for DR and 0.73 for CSME for grader 1, and κ = 0.77 (DR) and 0.77 (CSME) for grader 2. CONCLUSIONS Determination of CSME and grading of DR level from Optomap Panoramic 200 nonmydriatic images show a positive correlation with mydriatic ETDRS 7-field stereo photography. Both techniques are of sufficient quality to assess DR and CSME. Optomap Panoramic 200 images cover a larger retinal area and therefore may offer additional diagnostic properties. PMID:22912430
Kernt, Marcus; Hadi, Indrawati; Pinter, Florian; Seidensticker, Florian; Hirneiss, Christoph; Haritoglou, Christos; Kampik, Anselm; Ulbig, Michael W; Neubauer, Aljoscha S
2012-12-01
To compare the diagnostic properties of a nonmydriatic 200° ultra-widefield scanning laser ophthalmoscope (SLO) versus mydriatic Early Treatment of Diabetic Retinopathy Study (ETDRS) 7-field photography for diabetic retinopathy (DR) screening. A consecutive series of 212 eyes of 141 patients with different levels of DR were examined. Grading of DR and clinically significant macular edema (CSME) from mydriatic ETDRS 7-field stereo photography was compared with grading obtained by Optomap Panoramic 200 SLO images. All SLO scans were performed through an undilated pupil, and no additional clinical information was used for evaluation of all images by the two independent, masked, expert graders. Twenty-two eyes from ETDRS 7-field photography and 12 eyes from Optomap were not gradable by at least one grader because of poor image quality. A total of 144 eyes were analyzed regarding DR level and 155 eyes regarding CSME. For ETDRS 7-field photography, 22 eyes (18 for grader 2) had no or mild DR (ETDRS levels ≤ 20) and 117 eyes (111 for grader 2) had no CSME. A highly substantial agreement between both Optomap DR and CSME grading and ETDRS 7-field photography existed with κ = 0.79 for DR and 0.73 for CSME for grader 1, and κ = 0.77 (DR) and 0.77 (CSME) for grader 2. Determination of CSME and grading of DR level from Optomap Panoramic 200 nonmydriatic images show a positive correlation with mydriatic ETDRS 7-field stereo photography. Both techniques are of sufficient quality to assess DR and CSME. Optomap Panoramic 200 images cover a larger retinal area and therefore may offer additional diagnostic properties.
Kim, Kyung-A; Hyun, Lee Chung; Jung, Sang Hoon; Yang, Sung Jae
2016-01-01
In this study, the beneficial effects of the oral administration of ethanol extract of Diospyros kaki (EEDK) were tested on a mouse dry eye model induced by benzalkonium chloride (BAC). A solution of 0.2% BAC was administered topically to mouse eyes for 14 days, twice daily, to induce dry eye. Various concentrations of EEDK were administrated daily by oral gavage for 14 days after BAC treatment. Preservative-free eye drops were instilled in the positive-control group. The tear secretion volume (Schirmer's test), tear break-up time (BUT), and fluorescein score were measured on the ocular surface. BAC-induced corneal damage was tested with hematoxylin-eosin staining. Moreover, apoptotic cell death in the corneal epithelial layer was investigated with terminal deoxynucleotidyl transferase-mediated dUTP nick-end labeling (TUNEL) staining. The protein expression level of interleukin-1alpha (IL-1α), IL-1β, IL-6, tumor necrosis factor- alpha (TNF-α), and monocyte chemotactic protein-1 (MCP-1) was determined with western blot analysis. Furthermore, squamous metaplasia in the corneal epithelial layer was detected with immunofluorescent staining for cytokeratine-10. The cellular proliferation in the cornea was examined with immunohistochemical staining for Ki-67. EEDK treatment resulted in prolonged BUT, decreased fluorescein score, increased tear volume, and smoother epithelial cells compared with BAC treatment alone in the cornea. Moreover, EEDK treatment inhibited the inflammatory response and corneal epithelial cell death in a BAC-induced murine dry eye model, and changes in squamous cells were inhibited. Proliferative activity in the corneal epithelium cells was improved with EEDK. EEDK could be a potential therapeutic agent in the clinical treatment of dry eye.
Mohammadi, Seyed-Farzad; Sabbaghi, Mostafa; Z-Mehrjardi, Hadi; Hashemi, Hassan; Alizadeh, Somayeh; Majdi, Mercede; Taee, Farough
2012-03-01
To apply artificial intelligence models to predict the occurrence of posterior capsule opacification (PCO) after phacoemulsification. Farabi Eye Hospital, Tehran, Iran. Clinical-based cross-sectional study. The posterior capsule status of eyes operated on for age-related cataract and the need for laser capsulotomy were determined. After a literature review, data polishing, and expert consultation, 10 input variables were selected. The QUEST algorithm was used to develop a decision tree. Three back-propagation artificial neural networks were constructed with 4, 20, and 40 neurons in 2 hidden layers and trained with the same transfer functions (log-sigmoid and linear transfer) and training protocol with randomly selected eyes. They were then tested on the remaining eyes and the networks compared for their performance. Performance indices were used to compare resultant models with the results of logistic regression analysis. The models were trained using 282 randomly selected eyes and then tested using 70 eyes. Laser capsulotomy for clinically significant PCO was indicated or had been performed 2 years postoperatively in 40 eyes. A sample decision tree was produced with accuracy of 50% (likelihood ratio 0.8). The best artificial neural network, which showed 87% accuracy and a positive likelihood ratio of 8, was achieved with 40 neurons. The area under the receiver-operating-characteristic curve was 0.71. In comparison, logistic regression reached accuracy of 80%; however, the likelihood ratio was not measurable because the sensitivity was zero. A prototype artificial neural network was developed that predicted posterior capsule status (requiring capsulotomy) with reasonable accuracy. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Orbital Floor Reconstruction with Free Flaps after Maxillectomy
Sampathirao, Leela Mohan C. S. R.; Thankappan, Krishnakumar; Duraisamy, Sriprakash; Hedne, Naveen; Sharma, Mohit; Mathew, Jimmy; Iyer, Subramania
2013-01-01
Background The purpose of this study is to evaluate the outcome of orbital floor reconstruction with free flaps after maxillectomy. Methods This was a retrospective analysis of 34 consecutive patients who underwent maxillectomy with orbital floor removal for malignancies, reconstructed with free flaps. A cross-sectional survey to assess the functional and esthetic outcome was done in 28 patients who were alive and disease-free, with a minimum of 6 months of follow-up. Results Twenty-six patients had bony reconstruction, and eight had soft tissue reconstruction. Free fibula flap was the commonest flap used (n = 14). Visual acuity was normal in 86%. Eye movements were normal in 92%. Abnormal globe position resulted in nine patients. Esthetic satisfaction was good in 19 patients (68%). Though there was no statistically significant difference in outcome of visual acuity, eye movement, and patient esthetic satisfaction between patients with bony and soft tissue reconstruction, more patients without bony reconstruction had abnormal globe position (p = 0.040). Conclusion Free tissue transfer has improved the results of orbital floor reconstruction after total maxillectomy, preserving the eye. Good functional and esthetic outcome was achieved. Though our study favors a bony orbital reconstruction, a larger study with adequate power and equal distribution of patients among the groups would be needed to determine this. Free fibula flap remains the commonest choice when a bony reconstruction is contemplated. PMID:24436744
Orbital floor reconstruction with free flaps after maxillectomy.
Sampathirao, Leela Mohan C S R; Thankappan, Krishnakumar; Duraisamy, Sriprakash; Hedne, Naveen; Sharma, Mohit; Mathew, Jimmy; Iyer, Subramania
2013-06-01
Background The purpose of this study is to evaluate the outcome of orbital floor reconstruction with free flaps after maxillectomy. Methods This was a retrospective analysis of 34 consecutive patients who underwent maxillectomy with orbital floor removal for malignancies, reconstructed with free flaps. A cross-sectional survey to assess the functional and esthetic outcome was done in 28 patients who were alive and disease-free, with a minimum of 6 months of follow-up. Results Twenty-six patients had bony reconstruction, and eight had soft tissue reconstruction. Free fibula flap was the commonest flap used (n = 14). Visual acuity was normal in 86%. Eye movements were normal in 92%. Abnormal globe position resulted in nine patients. Esthetic satisfaction was good in 19 patients (68%). Though there was no statistically significant difference in outcome of visual acuity, eye movement, and patient esthetic satisfaction between patients with bony and soft tissue reconstruction, more patients without bony reconstruction had abnormal globe position (p = 0.040). Conclusion Free tissue transfer has improved the results of orbital floor reconstruction after total maxillectomy, preserving the eye. Good functional and esthetic outcome was achieved. Though our study favors a bony orbital reconstruction, a larger study with adequate power and equal distribution of patients among the groups would be needed to determine this. Free fibula flap remains the commonest choice when a bony reconstruction is contemplated.
Photogrammetry experiments with a model eye.
Rosenthal, A R; Falconer, D G; Pieper, I
1980-01-01
Digital photogrammetry was performed on stereophotographs of the optic nerve head of a modified Zeiss model eye in which optic cups of varying depths could be simulated. Experiments were undertaken to determine the impact of both photographic and ocular variables on the photogrammetric measurements of cup depth. The photogrammetric procedure tolerates refocusing, repositioning, and realignment as well as small variations in the geometric position of the camera. Progressive underestimation of cup depth was observed with increasing myopia, while progressive overestimation was noted with increasing hyperopia. High cylindrical errors at axis 90 degrees led to significant errors in cup depth estimates, while high cylindrical errors at axis 180 degrees did not materially affect the accuracy of the analysis. Finally, cup depths were seriously underestimated when the pupil diameter was less than 5.0 mm. Images PMID:7448139
Hiramoto, Keiichi; Kobayashi, Hiromi; Yamate, Yurika; Ishii, Masamitsu; Sato, Takao; Inoue, Masayasu
2013-02-01
Irradiation by ultraviolet (UV) B is known to increase the number of Dopa-positive melanocytes in the skin. This study examines the effectiveness of a contact lens for the defense of UVB eye irradiation-induced pigmentation. A 2.5 kJ/m(2) dose of UVB radiation was delivered by a sunlamp to the eye of C57BL/6j male mice, and changes in the expression of Dopa-positive melanocytes in the epidermis and the plasma level of alpha-melanocyte-stimulating hormone (α-MSH) was analyzed. The degree of change in the Dopa-positive melanocytes expression was reduced by UVB blocking contact lens using mice given UVB irradiation to the eye. The plasma level of α-MSH increased in the C57BL/6j mice after irradiation to the eye, but there was no increase in the UVB blocking contact lens mice given UVB irradiation to the eye. Both the increase of the expression of Dopa-positive melanocytes and the plasma level of α-MSH were strongly suppressed by an alignment fitting UVB blocking contact lens and only a slightly suspended UVB blocking contact lens. In addition, these changes were successfully inhibited by a UVB blocking contact lens but not by a non-UVB blocking contact lens with a similar absorbance. These observations suggest that the UVB blocking contact lens inhibits the pigmentation of the epidermis in mice by suppressing of the α-MSH. Copyright © 2012 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Donath, Lars; Kurz, Eduard; Roth, Ralf; Zahner, Lukas; Faude, Oliver
2016-09-01
Ageing impairs body balance and increases older adults' fall risk. Balance training can improve intrinsic fall risk factors. However, age comparisons of muscle activity responses during balance tasks are lacking. This study investigated relative muscle activity, muscle coordination and postural sway during various recommended static balance training tasks. Muscle activity (%MVC), amplitude ratios (AR) and co-activity (CAI) were determined during standing tasks for 30s (1: double limb stance on a foam surface, eyes open; 2: double limb stance on firm ground, eyes closed; 3: double limb stance, feet in step position on a foam surface, eyes open; 4: double limb stance, feet in step position on firm ground, eyes closed; 5: single limb stance on firm ground, eyes open) in 20 healthy young adults (24±2 y) and 20 older adults (73±6 y). Surface electromyography (SEMG) was applied (SENIAM guidelines) to ankle (tibialis anterior, soleus, medial gastrocnemius, peroneus longus) and thigh (vastus lateralis, vastus medialis, biceps femoris, semitendinosus) muscles (non-dominant leg). Electrodes over trunk (multifidus and internal oblique) muscles were applied bilaterally. Two- to six-fold higher levels of relative muscle activity were found in older adults for ankle (0.0002
Determination of loss tangent of human tear film at 9.8 GHz
NASA Astrophysics Data System (ADS)
Bansal, Namita; Dhaliwal, A. S.; Mann, K. S.
2015-08-01
Basal (non-stimulated) tears that are produced by accessory lacrimal glands located in conjunctiva of human eye, form tear film which in turn keeps the eye moist and lubricate; nourishes the eye; protects the eye from dust, bacterial infection and shear forces generated during eye movements and blinking; and provides a refractive surface on the corneal epithelium. Film is known to contain water, mucin, lipids, lysozyme, glucose, urea, sodium etc. In present communication, loss tangent of human tear film has been determined at 9.8 GHz microwaves by employing cavity perturbation technique at a temperature of 37°C. The basal tears from a small population comprising six subjects were collected and average value of loss tangent is reported. Slater's technique was used to reduce the error caused in measuring the volume of sample. The determined values are useful to study the biological effects of microwaves on tear film as well as other parts of human eye such as eye lens and lens epithelial cells. To the best of author's knowledge, no such study is available in literature at any radio as well as microwave frequencies; therefore present determinations are first of its kind.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-09
... DEPARTMENT OF STATE [Public Notice 6951] Culturally Significant Object Imported for Exhibition Determinations: ``Through African Eyes: The European in African Art, 1500--Present'' SUMMARY: Notice is hereby... object to be included in the exhibition ``Through African Eyes: The European in African Art, 1500...
NASA Technical Reports Server (NTRS)
Dickman, J. D.; Angelaki, D. E.
1999-01-01
During linear accelerations, compensatory reflexes should continually occur in order to maintain objects of visual interest as stable images on the retina. In the present study, the three-dimensional organization of the vestibulo-ocular reflex in pigeons was quantitatively examined during linear accelerations produced by constant velocity off-vertical axis yaw rotations and translational motion in darkness. With off-vertical axis rotations, sinusoidally modulated eye-position and velocity responses were observed in all three components, with the vertical and torsional eye movements predominating the response. Peak torsional and vertical eye positions occurred when the head was oriented with the lateral visual axis of the right eye directed orthogonal to or aligned with the gravity vector, respectively. No steady-state horizontal nystagmus was obtained with any of the rotational velocities (8-58 degrees /s) tested. During translational motion, delivered along or perpendicular to the lateral visual axis, vertical and torsional eye movements were elicited. No significant horizontal eye movements were observed during lateral translation at frequencies up to 3 Hz. These responses suggest that, in pigeons, all linear accelerations generate eye movements that are compensatory to the direction of actual or perceived tilt of the head relative to gravity. In contrast, no translational horizontal eye movements, which are known to be compensatory to lateral translational motion in primates, were observed under the present experimental conditions.
A generalised porous medium approach to study thermo-fluid dynamics in human eyes.
Mauro, Alessandro; Massarotti, Nicola; Salahudeen, Mohamed; Romano, Mario R; Romano, Vito; Nithiarasu, Perumal
2018-03-22
The present work describes the application of the generalised porous medium model to study heat and fluid flow in healthy and glaucomatous eyes of different subject specimens, considering the presence of ocular cavities and porous tissues. The 2D computational model, implemented into the open-source software OpenFOAM, has been verified against benchmark data for mixed convection in domains partially filled with a porous medium. The verified model has been employed to simulate the thermo-fluid dynamic phenomena occurring in the anterior section of four patient-specific human eyes, considering the presence of anterior chamber (AC), trabecular meshwork (TM), Schlemm's canal (SC), and collector channels (CC). The computational domains of the eye are extracted from tomographic images. The dependence of TM porosity and permeability on intraocular pressure (IOP) has been analysed in detail, and the differences between healthy and glaucomatous eye conditions have been highlighted, proving that the different physiological conditions of patients have a significant influence on the thermo-fluid dynamic phenomena. The influence of different eye positions (supine and standing) on thermo-fluid dynamic variables has been also investigated: results are presented in terms of velocity, pressure, temperature, friction coefficient and local Nusselt number. The results clearly indicate that porosity and permeability of TM are two important parameters that affect eye pressure distribution. Graphical abstract Velocity contours and vectors for healthy eyes (top) and glaucomatous eyes (bottom) for standing position.
Transposed-Letter Effects in Reading: Evidence from Eye Movements and Parafoveal Preview
ERIC Educational Resources Information Center
Johnson, Rebecca L.; Perea, Manuel; Rayner, Keith
2007-01-01
Three eye movement experiments were conducted to examine the role of letter identity and letter position during reading. Before fixating on a target word within each sentence, readers were provided with a parafoveal preview that differed in the amount of useful letter identity and letter position information it provided. In Experiments 1 and 2,…
NASA Astrophysics Data System (ADS)
Reutterer, Bernd; Traxler, Lukas; Bayer, Natascha; Drauschke, Andreas
2017-04-01
To evaluate the performance of intraocular lenses to treat cataract, an optomechanical eye model was developed. One of the most crucial components is the IOL holder, which should guarantee a physiological representation of the capsular bag and a stable position during measurement sequences. Individual holders are required due to the fact that every IOL has different geometric parameters. A method which allows obtaining the correct dimensions for the holder of a special IOL was developed and tested, by verifying the position of the IOL before and after a measurement sequence. Results of telecentric measurements and MTF measurements show that the IOL position does not change during the displacement sequence induced by the stepper motors of the eye model.
Hirata, Akimasa; Watanabe, Soichi; Taki, Masao; Fujiwara, Osamu; Kojima, Masami; Sasaki, Kazuyuki
2008-02-01
This study calculated the temperature elevation in the rabbit eye caused by 2.45-GHz near-field exposure systems. First, we calculated specific absorption rate distributions in the eye for different antennas and then compared them with those observed in previous studies. Next, we re-examined the temperature elevation in the rabbit eye due to a horizontally-polarized dipole antenna with a C-shaped director, which was used in a previous study. For our computational results, we found that decisive factors of the SAR distribution in the rabbit eye were the polarization of the electromagnetic wave and antenna aperture. Next, we quantified the eye average specific absorption rate as 67 W kg(-1) for the dipole antenna with an input power density at the eye surface of 150 mW cm(-2), which was specified in the previous work as the minimum cataractogenic power density. The effect of administrating anesthesia on the temperature elevation was 30% or so in the above case. Additionally, the position where maximum temperature in the lens appears is discussed due to different 2.45-GHz microwave systems. That position was found to appear around the posterior of the lens regardless of the exposure condition, which indicates that the original temperature distribution in the eye was the dominant factor.
Image-based computer-assisted diagnosis system for benign paroxysmal positional vertigo
NASA Astrophysics Data System (ADS)
Kohigashi, Satoru; Nakamae, Koji; Fujioka, Hiromu
2005-04-01
We develop the image based computer assisted diagnosis system for benign paroxysmal positional vertigo (BPPV) that consists of the balance control system simulator, the 3D eye movement simulator, and the extraction method of nystagmus response directly from an eye movement image sequence. In the system, the causes and conditions of BPPV are estimated by searching the database for record matching with the nystagmus response for the observed eye image sequence of the patient with BPPV. The database includes the nystagmus responses for simulated eye movement sequences. The eye movement velocity is obtained by using the balance control system simulator that allows us to simulate BPPV under various conditions such as canalithiasis, cupulolithiasis, number of otoconia, otoconium size, and so on. Then the eye movement image sequence is displayed on the CRT by the 3D eye movement simulator. The nystagmus responses are extracted from the image sequence by the proposed method and are stored in the database. In order to enhance the diagnosis accuracy, the nystagmus response for a newly simulated sequence is matched with that for the observed sequence. From the matched simulation conditions, the causes and conditions of BPPV are estimated. We apply our image based computer assisted diagnosis system to two real eye movement image sequences for patients with BPPV to show its validity.
Optimal Eye-Gaze Fixation Position for Face-Related Neural Responses
Zerouali, Younes; Lina, Jean-Marc; Jemel, Boutheina
2013-01-01
It is generally agreed that some features of a face, namely the eyes, are more salient than others as indexed by behavioral diagnosticity, gaze-fixation patterns and evoked-neural responses. However, because previous studies used unnatural stimuli, there is no evidence so far that the early encoding of a whole face in the human brain is based on the eyes or other facial features. To address this issue, scalp electroencephalogram (EEG) and eye gaze-fixations were recorded simultaneously in a gaze-contingent paradigm while observers viewed faces. We found that the N170 indexing the earliest face-sensitive response in the human brain was the largest when the fixation position is located around the nasion. Interestingly, for inverted faces, this optimal fixation position was more variable, but mainly clustered in the upper part of the visual field (around the mouth). These observations extend the findings of recent behavioral studies, suggesting that the early encoding of a face, as indexed by the N170, is not driven by the eyes per se, but rather arises from a general perceptual setting (upper-visual field advantage) coupled with the alignment of a face stimulus to a stored face template. PMID:23762224
Optimal eye-gaze fixation position for face-related neural responses.
Zerouali, Younes; Lina, Jean-Marc; Jemel, Boutheina
2013-01-01
It is generally agreed that some features of a face, namely the eyes, are more salient than others as indexed by behavioral diagnosticity, gaze-fixation patterns and evoked-neural responses. However, because previous studies used unnatural stimuli, there is no evidence so far that the early encoding of a whole face in the human brain is based on the eyes or other facial features. To address this issue, scalp electroencephalogram (EEG) and eye gaze-fixations were recorded simultaneously in a gaze-contingent paradigm while observers viewed faces. We found that the N170 indexing the earliest face-sensitive response in the human brain was the largest when the fixation position is located around the nasion. Interestingly, for inverted faces, this optimal fixation position was more variable, but mainly clustered in the upper part of the visual field (around the mouth). These observations extend the findings of recent behavioral studies, suggesting that the early encoding of a face, as indexed by the N170, is not driven by the eyes per se, but rather arises from a general perceptual setting (upper-visual field advantage) coupled with the alignment of a face stimulus to a stored face template.
Eye-hand coupling during closed-loop drawing: evidence of shared motor planning?
Reina, G Anthony; Schwartz, Andrew B
2003-04-01
Previous paradigms have used reaching movements to study coupling of eye-hand kinematics. In the present study, we investigated eye-hand kinematics as curved trajectories were drawn at normal speeds. Eye and hand movements were tracked as a monkey traced ellipses and circles with the hand in free space while viewing the hand's position on a computer monitor. The results demonstrate that the movement of the hand was smooth and obeyed the 2/3 power law. Eye position, however, was restricted to 2-3 clusters along the hand's trajectory and fixed approximately 80% of the time in one of these clusters. The eye remained stationary as the hand moved away from the fixation for up to 200 ms and saccaded ahead of the hand position to the next fixation along the trajectory. The movement from one fixation cluster to another consistently occurred just after the tangential hand velocity had reached a local minimum, but before the next segment of the hand's trajectory began. The next fixation point was close to an area of high curvature along the hand's trajectory even though the hand had not reached that point along the path. A visuo-motor illusion of hand movement demonstrated that the eye movement was influenced by hand movement and not simply by visual input. During the task, neural activity of pre-motor cortex (area F4) was recorded using extracellular electrodes and used to construct a population vector of the hand's trajectory. The results suggest that the saccade onset is correlated in time with maximum curvature in the population vector trajectory for the hand movement. We hypothesize that eye and arm movements may have common, or shared, information in forming their motor plans.
Eye-movements intervening between two successive sounds disrupt comparisons of auditory location
Pavani, Francesco; Husain, Masud; Driver, Jon
2008-01-01
Summary Many studies have investigated how saccades may affect the internal representation of visual locations across eye-movements. Here we studied instead whether eye-movements can affect auditory spatial cognition. In two experiments, participants judged the relative azimuth (same/different) of two successive sounds presented from a horizontal array of loudspeakers, separated by a 2.5 secs delay. Eye-position was either held constant throughout the trial (being directed in a fixed manner to the far left or right of the loudspeaker array), or had to be shifted to the opposite side of the array during the retention delay between the two sounds, after the first sound but before the second. Loudspeakers were either visible (Experiment1) or occluded from sight (Experiment 2). In both cases, shifting eye-position during the silent delay-period affected auditory performance in the successive auditory comparison task, even though the auditory inputs to be judged were equivalent. Sensitivity (d′) for the auditory discrimination was disrupted, specifically when the second sound shifted in the opposite direction to the intervening eye-movement with respect to the first sound. These results indicate that eye-movements affect internal representation of auditory location. PMID:18566808
Eye-movements intervening between two successive sounds disrupt comparisons of auditory location.
Pavani, Francesco; Husain, Masud; Driver, Jon
2008-08-01
Many studies have investigated how saccades may affect the internal representation of visual locations across eye-movements. Here, we studied, instead, whether eye-movements can affect auditory spatial cognition. In two experiments, participants judged the relative azimuth (same/different) of two successive sounds presented from a horizontal array of loudspeakers, separated by a 2.5-s delay. Eye-position was either held constant throughout the trial (being directed in a fixed manner to the far left or right of the loudspeaker array) or had to be shifted to the opposite side of the array during the retention delay between the two sounds, after the first sound but before the second. Loudspeakers were either visible (Experiment 1) or occluded from sight (Experiment 2). In both cases, shifting eye-position during the silent delay-period affected auditory performance in thn the successive auditory comparison task, even though the auditory inputs to be judged were equivalent. Sensitivity (d') for the auditory discrimination was disrupted, specifically when the second sound shifted in the opposite direction to the intervening eye-movement with respect to the first sound. These results indicate that eye-movements affect internal representation of auditory location.
Human Oculomotor Functions and Their Deficits in Traumatic Brain Injury
2012-02-01
be construed as an official Department of the Army position, policy or decision unless so designated by other documentation. REPORT... control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. 1. REPORT DATE February 2012 2. REPORT TYPE Annual 3. DATES COVERED 10 January...us to determine, for the first time in human, the oculomotor pathways in the brainstem for the major types of eye movement control , and establish
Prognostic value of gonioscopy after deep sclerectomy.
Moreno-Montañés, J; Rebolleda, G; Muñoz-Negrete, F J
2007-01-01
To ascertain gonioscopic characteristics and identify prognostic indicators related to intraocular pressure (IOP) after deep sclerectomy (DS). A transversal, prospective, and nonselected study was performed in 106 eyes (95 patients) after DS. Three surgeons performed all the surgeries and the gonioscopic examination, using the same protocol including 13 gonioscopic data. These data were evaluated for an association with postoperative IOP and time after surgery. A subscleral space was found in 91 eyes (85.8%), with visualization of the line of scleral flap in 48 eyes (45.3%). The trabeculo-Descemet membrane (TDM) was transparent in 46 eyes (43.4%), opaque in 4 cases, and pigmented in 18 eyes. This TDM was broken using Nd:YAG laser goniopuncture in 38 eyes(35.8%). Thin vessels around TDM were found in 58 eyes (54.7%), and blood remained in 25 eyes (23.5%). Gonioscopic variables significantly positively related with postoperative IOP were as follows: presence of subscleral space, scleral flap line view, and a Schwalbe line depressed. A narrow anterior chamber angle and iris synechia in TDM had a statistically significant negative effect on the postoperative IOP control. Similarly, eyes requiring Nd:YAG goniopuncture had a worse IOP control. The frequency of eyes with visible subscleral space and transparent TDM decreases with time after surgery (p=0.001). A visible subscleral space was a gonioscopic sign positively related to IOP control after surgery, although it decreased with follow-up. Eyes with goniopuncture, postoperative narrow angle, and iris synechia had worse postoperative IOP control. Although new vessels in TDM were a common finding after DS, the authors did not find any association with postoperative IOP.
Does mood influence text processing and comprehension? Evidence from an eye-movement study.
Scrimin, Sara; Mason, Lucia
2015-09-01
Previous research has indicated that mood influences cognitive processes. However, there is scarce data regarding the link between everyday emotional states and readers' text processing and comprehension. We aim to extend current research on the effects of mood induction on science text processing and comprehension, using eye-tracking methodology. We investigated whether a positive-, negative-, and neutral-induced mood influences online processing, as revealed by indices of visual behaviour during reading, and offline text comprehension, as revealed by post-test questions. We were also interested in the link between text processing and comprehension. Seventy-eight undergraduate students randomly assigned to three mood-induction conditions. Students were mood-induced by watching a video clip. They were then asked to read a scientific text while eye movements were registered. Pre- and post-reading knowledge was assessed through open-ended questions. Experimentally induced moods lead readers to process an expository text differently. Overall, students in a positive mood spent significantly longer on the text processing than students in the negative and neutral moods. Eye-movement patterns indicated more effective processing related to longer proportion of look-back fixation times in positive-induced compared with negative-induced readers. Students in a positive mood also comprehended the text better, learning more factual knowledge, compared with students in the negative group. Only for the positive-induced readers did the more purposeful second-pass reading positively predict text comprehension. New insights are given on the effects of normal mood variations and students' text processing and comprehension by the use of eye-tracking methodology. Important implications for the role of emotional states in educational settings are highlighted. © 2015 The British Psychological Society.
NASA Astrophysics Data System (ADS)
Nogueira, P.; Zankl, M.; Schlattl, H.; Vaz, P.
2011-11-01
The radiation-induced posterior subcapsular cataract has long been generally accepted to be a deterministic effect that does not occur at doses below a threshold of at least 2 Gy. Recent epidemiological studies indicate that the threshold for cataract induction may be much lower or that there may be no threshold at all. A thorough study of this subject requires more accurate dose estimates for the eye lens than those available in ICRP Publication 74. Eye lens absorbed dose per unit fluence conversion coefficients for electron irradiation were calculated using a geometrical model of the eye that takes into account different cell populations of the lens epithelium, together with the MCNPX Monte Carlo radiation transport code package. For the cell population most sensitive to ionizing radiation—the germinative cells—absorbed dose per unit fluence conversion coefficients were determined that are up to a factor of 4.8 higher than the mean eye lens absorbed dose conversion coefficients for electron energies below 2 MeV. Comparison of the results with previously published values for a slightly different eye model showed generally good agreement for all electron energies. Finally, the influence of individual anatomical variability was quantified by positioning the lens at various depths below the cornea. A depth difference of 2 mm between the shallowest and the deepest location of the germinative zone can lead to a difference between the resulting absorbed doses of up to nearly a factor of 5000 for electron energy of 0.7 MeV.
Nogueira, P; Zankl, M; Schlattl, H; Vaz, P
2011-11-07
The radiation-induced posterior subcapsular cataract has long been generally accepted to be a deterministic effect that does not occur at doses below a threshold of at least 2 Gy. Recent epidemiological studies indicate that the threshold for cataract induction may be much lower or that there may be no threshold at all. A thorough study of this subject requires more accurate dose estimates for the eye lens than those available in ICRP Publication 74. Eye lens absorbed dose per unit fluence conversion coefficients for electron irradiation were calculated using a geometrical model of the eye that takes into account different cell populations of the lens epithelium, together with the MCNPX Monte Carlo radiation transport code package. For the cell population most sensitive to ionizing radiation-the germinative cells-absorbed dose per unit fluence conversion coefficients were determined that are up to a factor of 4.8 higher than the mean eye lens absorbed dose conversion coefficients for electron energies below 2 MeV. Comparison of the results with previously published values for a slightly different eye model showed generally good agreement for all electron energies. Finally, the influence of individual anatomical variability was quantified by positioning the lens at various depths below the cornea. A depth difference of 2 mm between the shallowest and the deepest location of the germinative zone can lead to a difference between the resulting absorbed doses of up to nearly a factor of 5000 for electron energy of 0.7 MeV.
Stahl, John S; Oommen, Brian S
2008-01-01
Humans with cerebellar degeneration commonly exhibit downbeat nystagmus (DBN). DBN has gravity-independent and -dependent components, and the latter has been proposed to reflect hyperactive tilt maculo-ocular reflexes (tilt-MOR). Mice with genetically determined cerebellar ataxia do not exhibit DBN, but they do exhibit tonic hyperdeviation of the eyes, which we have proposed to be the DBN equivalent. As such, the tilt-MOR might be predicted to be hyperactive in these mutant mice. We measured the tilt-MOR in 10 normal C57BL/6 mice and in 6 tottering, a mutant exhibiting ataxia and ocular motor abnormalities due to mutation of the P/Q calcium channel. Awake mice were placed in body orientations spanning 360 degrees about the pitch axis. The absolute, equilibrium vertical angular deviations of one eye were measured using infrared videooculography. In both strains, eye elevation varied quasi-sinusoidally with tilt angle in the range of 90 degrees nose-up to 90 degrees nose-down. Beyond this range the eye returned to a neutral position. Deviation over +/-30 degrees of tilt was an approximately linear function of the projection of the gravity vector into the animal's horizontal plane, and can thus be summarized by its slope (sensitivity). Sensitivity measured 14.9 degrees/g for C57BL/6 and 20.3 degrees/g for tottering, a statistically significant difference. Thus the pitch otolithic reflex of the ataxic mutants is hyperactive relative to controls and could explain tonic hyperdeviation of the eyes, consistent with the idea that the tonic hyperdeviation is analogous to DBN.
Application of eye movement measuring system OBER 2 to medicine and technology
NASA Astrophysics Data System (ADS)
Ober, Jozef; Hajda, Janusz; Loska, Jacek; Jamicki, Michal
1997-08-01
The OBER 2 is an infrared light eye movement measuring system and it works with IBM PC compatible computers. As one of the safest systems for measuring of eye movement it uses a very short period of infrared light flashing time (80 microsecond for each measure point). System has an advanced analog-digital controller, which includes background suppression and prediction mechanisms guaranteeing elimination of slow changes and fluctuations of external illumination frequency up to 100 Hz, with effectiveness better than 40 dB. Setting from PC the active measure axis, sampling rate (25 - 4000 Hz) and making start and stop the measure, make it possible to control the outside environment in real-time. By proper controlling of gain it is possible to get high time and position resolution of 0.5 minute of arc even for big amplitude of eye movement (plus or minus 20 degree of visual angle). The whole communication system can also be driven directly by eye movement in real time. The possibility of automatic selection of the most essential elements of eye movement, individual for each person and those that take place for each person in determined situations of life independently from personal features, is a key to practical application. Hence one of conducted research topic is a personal identification based on personal features. Another task is a research project of falling asleep detection, which can be applied to warn the drivers before falling asleep while driving. This measuring system with a proper expert system can also be used to detect a dyslexia and other disabilities of the optic system.
Is screening with digital imaging using one retinal view adequate?
Herbert, H M; Jordan, K; Flanagan, D W
2003-05-01
To compare the detection of diabetic retinopathy from digital images with slit-lamp biomicroscopy, and to determine whether British Diabetic Association (BDA) screening criteria are attained (>80% sensitivity, >95% specificity, &<5% technical failure). Diabetics referred for screening were studied in a prospective fashion. A single 45 degrees fundus image was obtained using the nonmydriatic digital camera. Each patient subsequently underwent slit-lamp biomicroscopy and diabetic retinopathy grading by a consultant ophthalmologist. Diabetic retinopathy and maculopathy was graded according to the Early Treatment of Diabetic Retinopathy Study. A total of 145 patients (288 eyes) were identified for screening. Of these, 26% of eyes had diabetic retinopathy, and eight eyes (3%) had sight-threatening diabetic retinopathy requiring treatment. The sensitivity for detection of any diabetic retinopathy was 38% and the specificity 95%. There was a 4% technical failure rate. There were 42/288 false negatives and 10/288 false positives. Of the 42 false negatives, 18 represented diabetic maculopathy, 20 represented peripheral diabetic retinopathy and four eyes had both macular and peripheral changes. Three eyes in the false-negative group (1% of total eyes) had sight-threatening retinopathy. There was good concordance between the two consultants (79% agreement on slit-lamp biomicroscopy and 84% on digital image interpretation). The specificity value and technical failure rate compare favourably with BDA guidelines. The low sensitivity for detection of any retinopathy reflects failure to detect minimal maculopathy and retinopathy outside the 45 degrees image. This could be improved by an additional nasal image and careful evaluation of macular images with a low threshold for slit-lamp biomicroscopy if image quality is poor.
Micro-costing the provision of emotional support and information in UK eye clinics.
Gillespie-Gallery, Hanna; Subramanian, Ahalya; Conway, Miriam L
2013-11-19
Sight loss has wide ranging implications for an individual in terms of education, employment, mobility and mental health. Therefore there is a need for information and support to be provided in eye clinics at the point of diagnosis of sight threatening conditions, but these aspects of care are often missing from clinics. To meet these needs, some clinics employ an Eye Clinic Liaison Officer (ECLO) but the position has yet to be widely implemented. The aims of this study were:(1) To evaluate the forms of advice and emotional support in eye clinics provided by ECLOs.(2) To determine the cost of the ECLO service per patient. Micro-costing was carried out using interviews, a survey and administrative data. The survey was completed by 18 of the 49 accredited ECLOs in the UK (37%) and provided information on the activities performed by ECLOs, numbers of patients seen per day, training costs incurred and the salary of the ECLOs. ECLOs provided information about the services in eye clinics and the community, referral to social services, emotional support to patients and also other advice. The cost of an ECLO per patient per contact was £17.94 based on an average annual ECLO salary of £23,349.60 per year, reviewing on average 9.1 patients per day, in a 42 week year. This study provides the first costing of support services in hospital eye clinics, providing a range of estimates to suit the circumstances of different clinics. The information can be used by local decision makers to estimate the cost of implementing an ECLO service.
Croft, Mary Ann; McDonald, Jared P; James, Rebecca J; Heatley, Gregg A; Lin, Ting-Li; Lütjen-Drecoll, Elke; Kaufman, Paul L
2008-12-01
To determine how surgically altering the normal relationship between the lens and the ciliary body in rhesus monkeys affects centripetal ciliary body and lens movement. In 18 rhesus monkey eyes (aged 6-27 years), accommodation was induced before and after surgery by electrical stimulation of the Edinger-Westphal nucleus. Accommodative amplitude was measured by coincidence refractometry. Goniovideography was performed before and after intra- and extracapsular lens extraction (ICLE, ECLE) and anterior regional zonulolysis (ARZ). Centripetal lens/capsule movements, centripetal ciliary process (CP) movements, and circumlental space were measured by computerized image analysis of the goniovideography images. Centripetal accommodative CP and capsule movement increased in velocity and amplitude after, compared with before, ECLE regardless of age (n = 5). The presence of the lens substance retarded capsule movement by approximately 21% in the young eyes and by approximately 62% in the older eyes. Post-ICLE compared with pre-ICLE centripetal accommodative CP movement was dampened in all eyes in which the anterior vitreous was disrupted (n = 7), but not in eyes in which the anterior vitreous was left intact (n = 2). After anterior regional zonulolysis (n = 4), lens position shifted toward the lysed quadrant during accommodation. The presence of the lens substance, capsule zonular attachments, and Wieger's ligament may play a role in centripetal CP movement. The capsule is still capable of centripetal movement in the older eye (although at a reduced capacity) and may have the ability to produce approximately 6 D of accommodation in the presence of a normal, young crystalline lens or a similar surrogate.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tsai, Hui-Yu; Liao, Ying-Lan; Chang Gung University / Chang Gung Memorial Hospital, Taoyun, Taiwan
Purpose: The purpose of this study is to assess eye-lens dose for patients who underwent brain CT examinations using two dose reduction Methods: organ-based tube current modulation (OBTCM) and in-plane bismuth shielding method. Methods: This study received institutional review board approval; written informed consent to participate was obtained from all patients. Ninety patients who underwent the routine brain CT examination were randomly assigned to three groups, ie. routine, OBTCM, and bismuth shield. The OBTCM technique reduced the tube current when the X-ray tube rotates in front of patients’ eye-lens region. The patients in the bismuth shield group were covered one-plymore » bismuth shield in the eyes’ region. Eye-lens doses were measured using TLD-100H chips and the total effective doses were calculated using CT-Expo according to the CT scanning parameters. The surface doses for patients at off-center positions were assessed to evaluate the off-centering effect. Results: Phantom measurements indicates that OBTCM technique could reduced by 26% to 28% of the surface dose to the eye lens, and increased by 25% of the surface dose at the opposed incident direction at the angle of 180°. Patients’ eye-lens doses were reduced 16.9% and 30.5% dose of bismuth shield scan and OBTCM scan, respectively compared to the routine scan. The eye-lens doses were apparently increased when the table position was lower than isocenter. Conclusion: Reducing the dose to the radiosensitive organs, such as eye lens, during routine brain CT examinations could lower the radiation risks. The OBTCM technique and in-plane bismuth shielding could be used to reduce the eye-lens dose. The eye-lens dose could be effectively reduced using OBTCM scan without interfering the diagnostic image quality. Patient position relative the CT gantry also affects the dose level of the eye lens. This study was supported by the grants from the Ministry of Science and Technology of Taiwan (MOST103-2314-B-182-009-MY2), and Chang Gung Memorial Hospital (CMRPD1C0682)« less
Adaptation of catch-up saccades during the initiation of smooth pursuit eye movements.
Schütz, Alexander C; Souto, David
2011-04-01
Reduction of retinal speed and alignment of the line of sight are believed to be the respective primary functions of smooth pursuit and saccadic eye movements. As the eye muscles strength can change in the short-term, continuous adjustments of motor signals are required to achieve constant accuracy. While adaptation of saccade amplitude to systematic position errors has been extensively studied, we know less about the adaptive response to position errors during smooth pursuit initiation, when target motion has to be taken into account to program saccades, and when position errors at the saccade endpoint could also be corrected by increasing pursuit velocity. To study short-term adaptation (250 adaptation trials) of tracking eye movements, we introduced a position error during the first catch-up saccade made during the initiation of smooth pursuit-in a ramp-step-ramp paradigm. The target position was either shifted in the direction of the horizontally moving target (forward step), against it (backward step) or orthogonally to it (vertical step). Results indicate adaptation of catch-up saccade amplitude to back and forward steps. With vertical steps, saccades became oblique, by an inflexion of the early or late saccade trajectory. With a similar time course, post-saccadic pursuit velocity was increased in the step direction, adding further evidence that under some conditions pursuit and saccades can act synergistically to reduce position errors.
Blood culture bottles are superior to conventional media for vitreous culture.
Thariya, Patsuda; Yospaiboon, Yosanan; Sinawat, Suthasinee; Sanguansak, Thuss; Bhoomibunchoo, Chavakij; Laovirojjanakul, Wipada
2016-08-01
To compare blood culture bottles and conventional media for the vitreous culture in patients with clinically suspected infectious endophthalmitis. Retrospective comparative study at KKU Eye Center, Khon Kaen University. There were 342 patients with clinically suspected infectious endophthalmitis participated in the study. The vitreous specimens were inoculated in both blood culture bottles and on conventional culture media (blood agar, MacConkey agar, chocolate agar, Sabouraud dextrose agar and thioglycolate broth). The number of positive culture yields in both blood culture bottles and conventional media. Positive culture yields in both methods were found in 151 eyes (49.5%). There were 136 of 151 eyes (90.1%) with positive culture in blood culture bottles, whereas 99 of 151 eyes (65.6%) yielded positive cultures in conventional media. These findings were different with a statistical significance (P < 0.00001) and an odds ratio of 3.47 (95% confidence interval 1.92, 6.63). A combination of blood culture bottles and conventional media improved the yield. Blood culture bottles are superior to conventional media for vitreous culture in clinically suspected infectious endophthalmitis. Vitreous culture using blood culture bottles should be recommended as the primary method for microbiological diagnosis. A combination of both methods further improves the positive culture yield. © 2016 Royal Australian and New Zealand College of Ophthalmologists.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Asadi, Somayeh; Masoudi, Seyed Farhad, E-mail: masoudi@kntu.ac.ir; Shahriari, Majid
In ophthalmic brachytherapy dosimetry, it is common to consider the water phantom as human eye anatomy. However, for better clinical analysis, there is a need for the dose determination in different parts of the eye. In this work, a full human eye is simulated with MCNP-4C code by considering all parts of the eye, i.e., the lens, cornea, retina, choroid, sclera, anterior chamber, optic nerve, and bulk of the eye comprising vitreous body and tumor. The average dose in different parts of this full model of the human eye is determined and the results are compared with the dose calculatedmore » in water phantom. The central axes depth dose and the dose in whole of the tumor for these 2 simulated eye models are calculated as well, and the results are compared.« less
Fetal eye movements on magnetic resonance imaging.
Woitek, Ramona; Kasprian, Gregor; Lindner, Christian; Stuhr, Fritz; Weber, Michael; Schöpf, Veronika; Brugger, Peter C; Asenbaum, Ulrika; Furtner, Julia; Bettelheim, Dieter; Seidl, Rainer; Prayer, Daniela
2013-01-01
Eye movements are the physical expression of upper fetal brainstem function. Our aim was to identify and differentiate specific types of fetal eye movement patterns using dynamic MRI sequences. Their occurrence as well as the presence of conjugated eyeball motion and consistently parallel eyeball position was systematically analyzed. Dynamic SSFP sequences were acquired in 72 singleton fetuses (17-40 GW, three age groups [17-23 GW, 24-32 GW, 33-40 GW]). Fetal eye movements were evaluated according to a modified classification originally published by Birnholz (1981): Type 0: no eye movements; Type I: single transient deviations; Type Ia: fast deviation, slower reposition; Type Ib: fast deviation, fast reposition; Type II: single prolonged eye movements; Type III: complex sequences; and Type IV: nystagmoid. In 95.8% of fetuses, the evaluation of eye movements was possible using MRI, with a mean acquisition time of 70 seconds. Due to head motion, 4.2% of the fetuses and 20.1% of all dynamic SSFP sequences were excluded. Eye movements were observed in 45 fetuses (65.2%). Significant differences between the age groups were found for Type I (p = 0.03), Type Ia (p = 0.031), and Type IV eye movements (p = 0.033). Consistently parallel bulbs were found in 27.3-45%. In human fetuses, different eye movement patterns can be identified and described by MRI in utero. In addition to the originally classified eye movement patterns, a novel subtype has been observed, which apparently characterizes an important step in fetal brainstem development. We evaluated, for the first time, eyeball position in fetuses. Ultimately, the assessment of fetal eye movements by MRI yields the potential to identify early signs of brainstem dysfunction, as encountered in brain malformations such as Chiari II or molar tooth malformations.
Yun, Jun-Won; Hailian, Quan; Na, Yirang; Kang, Byeong-Cheol; Yoon, Jung-Hee; Cho, Eun-Young; Lee, Miri; Kim, Da-Eun; Bae, SeungJin; Seok, Seung Hyeok; Lim, Kyung-Min
2016-12-01
In an effort to explore the use of alternative methods to animal testing for the evaluation of the ocular irritancy of medical devices, we evaluated representative contact lenses with the bovine corneal opacity and permeability test (BCOP) and an in vitro eye irritation test using the three-dimensionally-reconstructed human corneal epithelium (RhCE) models, EpiOcular™ and MCTT HCE™. In addition, we compared the obtained results with the ISO standard in vivo rabbit eye irritation test (ISO10993-10). Along with the positive controls (benzalkonium chloride, BAK, 0.02, 0.2, and 1%), the extracts of 4 representative contact lenses (soft, disposable, hard, and colored lenses) and 2 reference lenses (dye-eluting and BAK-coated lenses) were tested. All the lenses, except for the BAK-coated lens, were determined non-irritants in all test methods, while the positive controls yielded relevant results. More importantly, BCOP, EpiOcular™, and MCTT HCE™ yielded a consistent decision for all the tested samples, with the exception of 0.2% BAK in BCOP, for which no prediction could be made. Overall, all the in vitro tests correlated well with the in vivo rabbit eye irritation test, and furthermore, the combination of in vitro tests as a tiered testing strategy was able to produce results similar to those seen in vivo. These observations suggest that such methods can be used as alternative assays to replace the conventional in vivo test method in the evaluation of the ocular irritancy of ophthalmic medical devices, although further study is necessary. Copyright © 2016. Published by Elsevier Ltd.
Illusory motion reveals velocity matching, not foveation, drives smooth pursuit of large objects
Ma, Zheng; Watamaniuk, Scott N. J.; Heinen, Stephen J.
2017-01-01
When small objects move in a scene, we keep them foveated with smooth pursuit eye movements. Although large objects such as people and animals are common, it is nonetheless unknown how we pursue them since they cannot be foveated. It might be that the brain calculates an object's centroid, and then centers the eyes on it during pursuit as a foveation mechanism might. Alternatively, the brain merely matches the velocity by motion integration. We test these alternatives with an illusory motion stimulus that translates at a speed different from its retinal motion. The stimulus was a Gabor array that translated at a fixed velocity, with component Gabors that drifted with motion consistent or inconsistent with the translation. Velocity matching predicts different pursuit behaviors across drift conditions, while centroid matching predicts no difference. We also tested whether pursuit can segregate and ignore irrelevant local drifts when motion and centroid information are consistent by surrounding the Gabors with solid frames. Finally, observers judged the global translational speed of the Gabors to determine whether smooth pursuit and motion perception share mechanisms. We found that consistent Gabor motion enhanced pursuit gain while inconsistent, opposite motion diminished it, drawing the eyes away from the center of the stimulus and supporting a motion-based pursuit drive. Catch-up saccades tended to counter the position offset, directing the eyes opposite to the deviation caused by the pursuit gain change. Surrounding the Gabors with visible frames canceled both the gain increase and the compensatory saccades. Perceived speed was modulated analogous to pursuit gain. The results suggest that smooth pursuit of large stimuli depends on the magnitude of integrated retinal motion information, not its retinal location, and that the position system might be unnecessary for generating smooth velocity to large pursuit targets. PMID:29090315
A medieval fallacy: the crystalline lens in the center of the eye.
Leffler, Christopher T; Hadi, Tamer M; Udupa, Akrithi; Schwartz, Stephen G; Schwartz, Daniel
2016-01-01
To determine whether, as most modern historians have written, ancient Greco-Roman authors believed the crystalline lens is positioned in the center of the eye. Historians have written that statements about cataract couching by Celsus, or perhaps Galen of Pergamon, suggested a centrally located lens. Celsus specifically wrote that a couching needle placed intermediate between the corneal limbus and the lateral canthus enters an empty space, presumed to represent the posterior chamber. Ancient ophthalmic literature was analyzed to understand where these authors believed the crystalline lens was positioned. In order to estimate where Celsus proposed entering the eye during couching, we prospectively measured the distance from the temporal corneal limbus to the lateral canthus in 30 healthy adults. Rufus of Ephesus and Galen wrote that the lens is anterior enough to contact the iris. Galen wrote that the lens equator joins other ocular structures at the corneoscleral junction. In 30 subjects, half the distance from the temporal corneal limbus to the lateral canthus was a mean of 4.5 mm (range: 3.3-5.3 mm). Descriptions of couching by Celsus and others are consistent with pars plana entry of the couching needle. Anterior angulation of the needle would permit contact of the needle with the lens. Ancient descriptions of anatomy and couching do not establish the microanatomic relationships of the ciliary region with any modern degree of accuracy. Nonetheless, ancient authors, such as Galen and Rufus, clearly understood that the lens is located anteriorly. There is little reason to believe that Celsus or other ancient authors held a variant understanding of the anatomy of a healthy eye. The notion of the central location of the lens seems to have arisen with Arabic authors in 9th century Mesopotamia, and lasted for over 7 centuries.
Spatial orientation of caloric nystagmus in semicircular canal-plugged monkeys.
Arai, Yasuko; Yakushin, Sergei B; Cohen, Bernard; Suzuki, Jun-Ichi; Raphan, Theodore
2002-08-01
We studied caloric nystagmus before and after plugging all six semicircular canals to determine whether velocity storage contributed to the spatial orientation of caloric nystagmus. Monkeys were stimulated unilaterally with cold ( approximately 20 degrees C) water while upright, supine, prone, right-side down, and left-side down. The decline in the slow phase velocity vector was determined over the last 37% of the nystagmus, at a time when the response was largely due to activation of velocity storage. Before plugging, yaw components varied with the convective flow of endolymph in the lateral canals in all head orientations. Plugging blocked endolymph flow, eliminating convection currents. Despite this, caloric nystagmus was readily elicited, but the horizontal component was always toward the stimulated (ipsilateral) side, regardless of head position relative to gravity. When upright, the slow phase velocity vector was close to the yaw and spatial vertical axes. Roll components became stronger in supine and prone positions, and vertical components were enhanced in side down positions. In each case, this brought the velocity vectors toward alignment with the spatial vertical. Consistent with principles governing the orientation of velocity storage, when the yaw component of the velocity vector was positive, the cross-coupled pitch or roll components brought the vector upward in space. Conversely, when yaw eye velocity vector was downward in the head coordinate frame, i.e., negative, pitch and roll were downward in space. The data could not be modeled simply by a reduction in activity in the ipsilateral vestibular nerve, which would direct the velocity vector along the roll direction. Since there is no cross coupling from roll to yaw, velocity storage alone could not rotate the vector to fit the data. We postulated, therefore, that cooling had caused contraction of the endolymph in the plugged canals. This contraction would deflect the cupula toward the plug, simulating ampullofugal flow of endolymph. Inhibition and excitation induced by such cupula deflection fit the data well in the upright position but not in lateral or prone/supine conditions. Data fits in these positions required the addition of a spatially orientated, velocity storage component. We conclude, therefore, that three factors produce cold caloric nystagmus after canal plugging: inhibition of activity in ampullary nerves, contraction of endolymph in the stimulated canals, and orientation of eye velocity to gravity through velocity storage. Although the response to convection currents dominates the normal response to caloric stimulation, velocity storage probably also contributes to the orientation of eye velocity.
Optimizations and Applications in Head-Mounted Video-Based Eye Tracking
ERIC Educational Resources Information Center
Li, Feng
2011-01-01
Video-based eye tracking techniques have become increasingly attractive in many research fields, such as visual perception and human-computer interface design. The technique primarily relies on the positional difference between the center of the eye's pupil and the first-surface reflection at the cornea, the corneal reflection (CR). This…
Visual Short-Term Memory During Smooth Pursuit Eye Movements
ERIC Educational Resources Information Center
Kerzel, Dirk; Ziegler, Nathalie E.
2005-01-01
Visual short-term memory (VSTM) was probed while observers performed smooth pursuit eye movements. Smooth pursuit keeps a moving object stabilized in the fovea. VSTM capacity for position was reduced during smooth pursuit compared with a condition with eye fixation. There was no difference between a condition in which the items were approximately…
Apparatus and method for non-contact, acoustic resonance determination of intraocular pressure
Sinha, Dipen N.; Wray, William O.
1994-01-01
Apparatus and method for measuring intraocular pressure changes in an eye under investigation by detection of vibrational resonances therein. An ultrasonic transducer operating at its resonant frequency is amplitude modulated and swept over a range of audio frequencies in which human eyes will resonate. The output therefrom is focused onto the eye under investigation, and the resonant vibrations of the eye observed using a fiber-optic reflection vibration sensor. Since the resonant frequency of the eye is dependent on the pressure therein, changes in intraocular pressure may readily be determined after a baseline pressure is established.
Apparatus and method for non-contact, acoustic resonance determination of intraocular pressure
Sinha, D.N.; Wray, W.O.
1994-12-27
The apparatus and method for measuring intraocular pressure changes in an eye under investigation by detection of vibrational resonances therein. An ultrasonic transducer operating at its resonant frequency is amplitude modulated and swept over a range of audio frequencies in which human eyes will resonate. The output therefrom is focused onto the eye under investigation, and the resonant vibrations of the eye observed using a fiber-optic reflection vibration sensor. Since the resonant frequency of the eye is dependent on the pressure therein, changes in intraocular pressure may readily be determined after a baseline pressure is established. 3 figures.
Guinea Pig Ciliary Muscle Development
Pucker, Andrew D.; Carpenter, Ashley R.; McHugh, Kirk M.; Mutti, Donald O.
2014-01-01
Purpose The purpose of this study was to develop a method for quantifying guinea pig ciliary muscle volume (CMV) and to determine its relationship to age and ocular biometric measurements. Methods Six albino guinea pigs eyes were collected at each of five ages (n=30 eyes). Retinoscopy and photography were used to document refractive error, eye size, and eye shape. Serial sections through the excised eyes were made and then labeled with an α-smooth muscle actin antibody. The CM was then visualized with an Olympus BX51 microscope, reconstructed with Stereo Investigator (MBF Bioscience) and analyzed using Neurolucida Explorer (MBF Bioscience). Full (using all sections) and partial (using a subset of sections) reconstruction methods were used to determine CMV. Results There was no significant difference between the full and partial volume determination methods (P = 0.86). The mean CMV of the 1, 10, 20, 30, and 90-day old eyes was 0.40 ± 0.16 mm3, 0.48 ± 0.13 mm3, 0.67 ± 0.15 mm3, 0.86 ± 0.35 mm3, and 1.09 ± 0.63 mm3, respectively. CMV was significantly correlated with log age (P = 0.001), ocular length (P = 0.003), limbal circumference (P = 0.01), and equatorial diameter (P = 0.003). It was not correlated with refractive error (P = 0.73) or eye shape (P = 0.60). Multivariate regression determined that biometric variables were not significantly associated with CMV after adjustment for age. Conclusions Three-dimensional reconstruction was an effective means of determining CMV. These data provide evidence that CM growth occurs with age in tandem with eye size in normal albino guinea pigs. Additional work is needed to determine the relationship between CMV and abnormal ocular growth. PMID:24901488
Six-Position, Frontal View Photography in Blepharoplasty: A Simple Method.
Zhang, Cheng; Guo, Xiaoshuang; Han, Xuefeng; Tian, Yi; Jin, Xiaolei
2018-02-26
Photography plays a pivotal role in patient education, photo-documentation, preoperative planning and postsurgical evaluation in plastic surgeries. It has long been serving as a bridge that facilitated communication not only between patients and doctors, but also among plastic surgeons from different countries. Although several basic principles and photographic methods have been proposed, there is no internationally accepted photography that could provide both static and dynamic information in blepharoplasty. In this article, we introduced a novel six-position, frontal view photography for thorough assessment in blepharoplasty. From October 2013 to January 2017, 1068 patients who underwent blepharoplasty were enrolled in our clinical research. All patients received six-position, frontal view photography. Pictures were taken of the patients looking up, looking down, squeezing, smiling, looking ahead and with closed eyes. Conventionally, frontal view photography only contained the last two positions. Then, both novel six-position photographs and conventional two-position photographs were used to appraise postsurgical outcomes. Compared to conventional two-position, frontal view photography, six-position, frontal view photography can provide more detailed, thorough information about the eyes. It is of clinical significance in indicating underlying adhesion of skin/muscle/fat according to individual's features and assessing preoperative and postoperative dynamic changes and aesthetic outcomes. Six-position, frontal view photography is technically uncomplicated while exhibiting static, dynamic and detailed information of the eyes. This innovative method is favorable in eye assessment, especially for revision blepharoplasty. We suggest using six-position, frontal view photography to obtain comprehensive photographs. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-13
... DEPARTMENT OF STATE [Public Notice: 7580] Culturally Significant Objects Imported for Exhibition Determinations: ``Adapting the Eye: An Archive of the British in India, 1770-1830'' Summary: Notice is hereby... objects to be included in the exhibition ``Adapting the Eye: An Archive of the British in India, 1770-1830...
Physiological responses to the Coriolis illusion: effects of head position and vision.
Westmoreland, David; Krell, Robert W; Self, Brian P
2007-10-01
Changes in sympathetic outflow during Type II spatial disorientation are well documented. In this study we investigated the influences of head position and eye state (open or closed) on sympathetic activation. There were 11 naive subjects (6 men, 5 women) who were tested in a General Aviation Trainer that accelerated at a subthreshold rate for 60 s until a constant angular velocity of 90 degrees x s(-1) was reached. Approximately 40 s later, subjects were instructed to tilt their heads along either the pitch or roll axis, stimulating a Coriolis illusion. Subjects reported the perceived intensity and duration of disorientation. Heart rate, heart rate variability, and electrodermal responses were recorded before, during, and after the period of disorientation. Each subject completed four trials, which were crossed combinations of head position and eye state. There were significant increases in heart rate and the electrodermal response during disorientation, but no significant change in heart rate variability. Head position had no significant effect on any physiological parameters or on the perceived intensity of disorientation; subjects reported a shorter duration of disorientation when the head was tilted into the roll versus the pitch axis. Eye state had no effect on heart rate, heart rate variability, or the intensity of disorientation, but the electrodermal response was somewhat greater, and the duration of disorientation shorter when eyes were open. The results suggest that head position and eye state (open or closed) do not need to be included as factors when investigating sympathetic outflow during a mild Coriolis illusion.
Declues, Kari; Perez, Shelli; Figueroa, Ariana
2018-03-01
Whole blood samples were examined for ∆ 9 -Tetrahydrocannabinol (THC) over 2 years in drivers suspected of driving under the influence. Part one of the study examined the link between [THC] and performance on field sobriety tests. This portion examined objective signs, eye examinations and physiological indicators; and their relationship to the presence of THC. Several objective signs were excellent indicators of the presence of THC: red eyes (94%), droopy eyelids (85.6%), affected speech (87.6%), tongue coating (96.2%), and odor of marijuana (82.4%). About 63.6% of THC positive subjects had dialted pupils (room light). THC positive subjects had either rebound dilation or hippus in 88.8% of cases. Pulse and blood pressure (BP) were evaluated to determine any correlation with [THC]. An increased pulse rate correlated well to the presence of THC (88.5%), but not [THC]. BP did not correlate to [THC] and was also a poor indicator of THC in the blood (50% high). © 2017 American Academy of Forensic Sciences.
The effect of extended wake on postural control in young adults.
Smith, Simon S; Cheng, Tiffany; Kerr, Graham K
2012-09-01
The sleep-wake cycle is a major determinant of locomotor activity in humans, and the neural and physiological processes necessary for optimum postural control may be impaired by an extension of the wake period into habitual sleep time. There is growing evidence for such a contribution from sleep-related factors, but great inconsistency in the methods used to assess this contribution, particularly in control for circadian phase position. Postural control was assessed at hourly intervals across 14 h of extended wake in nine young adult participants. Force plate parameters of medio-lateral and anterior-posterior sway, centre of pressure (CoP) trace length, area, and velocity were assessed with eyes open and eyes closed over 3-min periods. A standard measure of psychomotor vigilance was assessed concurrently under constant routine conditions. After controlling for individual differences in circadian phase position, a significant effect of extended wake was found for anterior-posterior sway and for psychomotor vigilance. These data suggest that extended wake may increase the risk of a fall or other consequences of impaired postural control.
Balance training and center-of-pressure location in participants with chronic ankle instability.
Mettler, Abby; Chinn, Lisa; Saliba, Susan A; McKeon, Patrick O; Hertel, Jay
2015-04-01
Chronic ankle instability (CAI) occurs in some people after a lateral ankle sprain and often results in residual feelings of instability and episodes of the ankle's giving way. Compared with healthy people, patients with CAI demonstrated poor postural control and used a more anteriorly and laterally positioned center of pressure (COP) during a single-limb static-balance task on a force plate. Balance training is an effective means of altering traditional COP measures; however, whether the overall location of the COP distribution under the foot also changes is unknown. To determine if the spatial locations of COP data points in participants with CAI change after a 4-week balance-training program. Randomized controlled trial. Laboratory. Thirty-one persons with self-reported CAI. Participants were randomly assigned to a 4-week balance-training program or no balance training. We collected a total of 500 COP data points while participants balanced using a single limb on a force plate during a 10-second trial. The location of each COP data point relative to the geometric center of the foot was determined, and the frequency count in 4 sections (anteromedial, anterolateral, posteromedial, posterolateral) was analyzed for differences between groups. Overall, COP position in the balance-training group shifted from being more anterior to less anterior in both eyes-open trials (before trial = 319.1 ± 165.4, after trial = 160.5 ± 149.5; P = .006) and eyes-closed trials (before trial = 387.9 ± 123.8, after trial = 189.4 ± 102.9; P < .001). The COP for the group that did not perform balance training remained the same in the eyes-open trials (before trial = 214.1 ± 193.3, after trial = 230.0 ± 176.3; P = .54) and eyes-closed trials (before trial = 326.9 ± 134.3, after trial = 338.2 ± 126.1; P = .69). In participants with CAI, the balance-training program shifted the COP location from anterolateral to posterolateral. The program may have repaired some of the damaged sensorimotor system pathways, resulting in a more optimally functioning and less constrained system.
Visual Contrast Sensitivity in Early-Stage Parkinson's Disease.
Ming, Wendy; Palidis, Dimitrios J; Spering, Miriam; McKeown, Martin J
2016-10-01
Visual impairments are frequent in Parkinson's disease (PD) and impact normal functioning in daily activities. Visual contrast sensitivity is a powerful nonmotor sign for discriminating PD patients from controls. However, it is usually assessed with static visual stimuli. Here we examined the interaction between perception and eye movements in static and dynamic contrast sensitivity tasks in a cohort of mildly impaired, early-stage PD patients. Patients (n = 13) and healthy age-matched controls (n = 12) viewed stimuli of various spatial frequencies (0-8 cyc/deg) and speeds (0°/s, 10°/s, 30°/s) on a computer monitor. Detection thresholds were determined by asking participants to adjust luminance contrast until they could just barely see the stimulus. Eye position was recorded with a video-based eye tracker. Patients' static contrast sensitivity was impaired in the intermediate spatial-frequency range and this impairment correlated with fixational instability. However, dynamic contrast sensitivity and patients' smooth pursuit were relatively normal. An independent component analysis revealed contrast sensitivity profiles differentiating patients and controls. Our study simultaneously assesses perceptual contrast sensitivity and eye movements in PD, revealing a possible link between fixational instability and perceptual deficits. Spatiotemporal contrast sensitivity profiles may represent an easily measurable metric as a component of a broader combined biometric for nonmotor features observed in PD.
Yünlü, Önder; Özçelik, Semra; Arıcı, Mustafa Kemal
2015-09-01
In the study, it is aimed to determine the prevalence of Acanthamoeba and other free-living amoeba (FLA) species in the swab samples obtained from conjunctiva and lower eye lid. For this purpose, swab samples from the 500 patients'eye lid and conjunctiva were obtained who admitted to Cumhuriyet University, Research and Application Hospital, Department of Ophthalmology with variety of reasons. Swab samples were carried out using sterile cotton swab in steril tubes. The swab samples were inoculated onto non-nutrient agar (NNA). Live Escherichia coli was used as food source for the growth of the FLA. The NNA plates were incubated at 300C and examined daily using ligth microscope for two weeks. For morphotyping of the trophozoites and cysts of the FLA were used taxonomic keys. Two of the 500 swab samples (0.4%) were positive for FLA. One of them (0.2%) were identified as Acanthamoeba spp. and other was identified as Hartmannella spp. However, these patients did not reveal any complaints yet. FLA both themselves and bacteria carrying in their body as reservoirs are potential pathogen. The rapid spread of Acanthamoeba keratitis in recent years reveal that these microorganisms are in contact with the eyes.
Analysis of Th17-associated cytokines in tears of patients with dry eye syndrome.
Tan, X; Sun, S; Liu, Y; Zhu, T; Wang, K; Ren, T; Wu, Z; Xu, H; Zhu, L
2014-05-01
To determine the levels of Th17-associated cytokines, particularly interleukin (IL)-17 and IL-22 in tears of patients with dry eye syndrome. Tear samples were collected from 20 healthy volunteers, 20 dry eye (DE) patients with non-Sjögren's syndrome (NSSDE) and 20 DE patients with Sjögren's syndrome (SSDE). Symptom questionnaire was self-administered and multiple dry eye disease (DED)-related clinical tests were performed. The levels of IL-17 and IL-22 in tears were measured by enzyme-linked immunosorbent assay. The levels of IL-17 and IL-22 were significantly increased in tears of DE patients compared with those of controls and also higher in SSDE patients compared with those of NSSDE patients (P<0.05). Moreover, the levels of IL-17 and IL-22 were positively correlated with questionnaire score and keratopathy score but negatively correlated with tear film break-up time and Schirmer I test in both NSSDE and SSDE patients (P<0.05). The levels of IL-17 and IL-22 in tears were significantly increased in DE patients, which were associated with the disease severity. Therefore, Th17 cell-associated cytokines, particularly IL-17 and IL-22, may have important roles in the immunopathogenesis of the DED.
Dose rate constants for the quantity Hp(3) for frequently used radionuclides in nuclear medicine.
Szermerski, Bastian; Bruchmann, Iris; Behrens, Rolf; Geworski, Lilli
2016-12-01
According to recent studies, the human eye lens is more sensitive to ionising radiation than previously assumed. Therefore, the dose limit for personnel occupationally exposed to ionising radiation will be lowered from currently 150 mSv to 20 mSv per year. Currently, no data base for a reliable estimation of the dose to the lens of the eye is available for nuclear medicine. Furthermore, the dose is usually not monitored. The aim of this work was to determine dose rate constants for the quantity H p (3), which is supposed to estimate the dose to the lens of the eye. For this, H p (3)-dosemeters were fixed to an Alderson Phantom at different positions. The dosemeters were exposed to radiation from nuclides typically used in nuclear medicine in their geometries analog to their application in nuclear medicine, e.g. syringe or vial. The results show that the handling of high-energy beta (i.e. electron or positron) emitters may lead to a relevant dose to the lens of the eye. For low-energy beta emitters and gamma emitters, an exceeding of the lowered dose limit seems to be unlikely. Copyright © 2015. Published by Elsevier GmbH.
Rett syndrome: basic features of visual processing-a pilot study of eye-tracking.
Djukic, Aleksandra; Valicenti McDermott, Maria; Mavrommatis, Kathleen; Martins, Cristina L
2012-07-01
Consistently observed "strong eye gaze" has not been validated as a means of communication in girls with Rett syndrome, ubiquitously affected by apraxia, unable to reply either verbally or manually to questions during formal psychologic assessment. We examined nonverbal cognitive abilities and basic features of visual processing (visual discrimination attention/memory) by analyzing patterns of visual fixation in 44 girls with Rett syndrome, compared with typical control subjects. To determine features of visual fixation patterns, multiple pictures (with the location of the salient and presence/absence of novel stimuli as variables) were presented on the screen of a TS120 eye-tracker. Of the 44, 35 (80%) calibrated and exhibited meaningful patterns of visual fixation. They looked longer at salient stimuli (cartoon, 2.8 ± 2 seconds S.D., vs shape, 0.9 ± 1.2 seconds S.D.; P = 0.02), regardless of their position on the screen. They recognized novel stimuli, decreasing the fixation time on the central image when another image appeared on the periphery of the slide (2.7 ± 1 seconds S.D. vs 1.8 ± 1 seconds S.D., P = 0.002). Eye-tracking provides a feasible method for cognitive assessment and new insights into the "hidden" abilities of individuals with Rett syndrome. Copyright © 2012 Elsevier Inc. All rights reserved.
Acute air pollution-related symptoms among residents in Chiang Mai, Thailand.
Wiwatanadate, Phongtape
2014-01-01
Open burnings (forest fires, agricultural, and garbage burnings) are the major sources of air pollution in Chiang Mai, Thailand. A time series prospective study was conducted in which 3025 participants were interviewed for 19 acute symptoms with the daily records of ambient air pollutants: particulate matter less than 10 microm in size (PM10), carbon monoxide (CO), nitrogen dioxide (NO2), sulfur dioxide (SO2), and ozone (O3). PM10 was positively associated with blurred vision with an adjusted odds ratio (OR) of 1.009. CO was positively associated with lower lung and heart symptoms with adjusted ORs of 1.137 and 1.117. NO2 was positively associated with nosebleed, larynx symptoms, dry cough, lower lung symptoms, heart symptoms, and eye irritation with the range of adjusted ORs (ROAORs) of 1.024 to 1.229. SO2 was positively associated with swelling feet, skin symptoms, eye irritation, red eyes, and blurred vision with ROAORs of 1.205 to 2.948. Conversely, O3 was negatively related to running nose, burning nose, dry cough, body rash, red eyes, and blurred vision with ROAORs of 0.891 to 0.979.
Detection of Potentially Severe Retinopathy of Prematurity by Remote Image Grading.
Quinn, Graham E; Ying, Gui-Shuang; Pan, Wei; Baumritter, Agnieshka; Daniel, Ebenezer
2017-09-01
Telemedicine in retinopathy of prematurity (ROP) has the potential for delivering timely care to premature infants at risk for serious ROP. To describe the characteristics of eyes at risk for ROP to provide insights into what types of ROP are most easily detected early by image grading. Secondary analysis of eyes with referral-warranted (RW) ROP (stage 3 ROP, zone I ROP, plus disease) on diagnostic examination from the Telemedicine Approaches to Evaluating Acute-Phase Retinopathy of Prematurity (e-ROP) study was conducted from May 1, 2011, to October 31, 2013, in 1257 premature infants with birth weights less than 1251 g in 13 neonatal units in North America. Data analysis was performed between February 1, 2016, and June 5, 2017. Serial imaging sessions with concurrent diagnostic examinations for ROP. Time of detecting RW-ROP on image evaluation compared with clinical examination. In the e-ROP study, 246 infants (492 eyes) were included in the analysis; 138 (56.1%) were male. A total of 447 eyes had RW-ROP on diagnostic examination. Image grading in 123 infants (mean [SD] gestational age, 24.8 [1.4] weeks) detected RW-ROP earlier than diagnostic examination (early) in 191 (42.7%) eyes by about 15 days and detected RW-ROP in 123 infants (mean [SD] gestational age, 24.6 [1.5] weeks) at the same time (same) in 200 (44.7%) eyes. Most of the early eyes (153 [80.1%]) interpreted as being RW-ROP positive on imaging evaluation agreed with examination findings when the examination subsequently documented RW-ROP. At the sessions in which RW-ROP was first found by examination, stage 3 or more in 123 infants (mean [SD] gestational age, 24.8 [1.4] weeks) ROP was noted earlier on image evaluation in 151 of 191 early eyes (79.1%) and in 172 of 200 of same eyes (86.0%) (P = .08); the presence of zone I ROP was detected in 57 of 191 (29.8%) early eyes vs 64 of 200 (32.0%) same eyes (P = .90); and plus disease was noted in 30 of 191 (15.7%) early eyes and 45 of 200 (22.5%) same eyes (P = .08). In both early and same eyes, zone I and/or stage 3 ROP determined a significant proportion of RW-ROP; plus disease played a relatively minor role. In most early RW-ROP eyes, the findings were consistent with clinical examination and/or image grading at the next session. Because ROP telemedicine is used more widely, development of standard approaches and protocols is essential.
Development of Pointing Device Using DC-Coupled Electrooculogram
NASA Astrophysics Data System (ADS)
Uchitomi, Hirotaka; Hori, Junichi
A purpose of this study is to support communication of developmentally disabled individuals with motor paralysis, such as Guillain-Barre Syndrome, brain-stem infarction, having difficulty in conveying their intention. In the present paper, a pointing device controlled by DC-coupled electrooculograms (EOGs) has been developed. The optic angle of the subject was estimated from the amplitude of vertical and horizontal EOGs for determining the two dimensional pointing position on the PC screen in real time. The eye blinking artifact was reduced using a median filter. The displacement of electrode position was compensated by considering the potential gradient. Moreover, the position error caused by drift phenomenon was adjusted by using head movement. The accuracy and operating speed of the proposed method were evaluated in human experiments.
Susceptibility of proliferating cells to benzo[a]pyrene-induced homologous recombination in mice.
Bishop, A J; Kosaras, B; Carls, N; Sidman, R L; Schiestl, R H
2001-04-01
The pink-eyed unstable mutation, p(un), is the result of a 70 kb tandem duplication within the murine pink-eyed, p, gene. Deletion of one copy of the duplicated region by homologous deletion/recombination occurs spontaneously in embryos and results in pigmented spots in the fur and eye. Such deletion events are inducible by a variety of DNA damaging agents, as we have observed previously with both fur- and eye-spot assays. Here we describe a study of the effect of exposure to benzo[a]pyrene (B[a]P) at different times of development on reversion induction in the eye. Previously we, among others, have reported that the retinal pigment epithelium (RPE) displays a position effect variegation phenotype in the pattern of pink-eyed unstable reversions. Following an acute exposure to B[a]P or X-rays on the tenth day of gestation an increased frequency of reversion events was detected in a distinct region of the adult RPE. Examining exposure at different times of eye development reveals that both B[a]P and X-rays result in an increased frequency of reversion events, though the increase was only significant following B[a]P exposure, similar to our previous report limited to exposure on the tenth day of gestation. Examination of B[a]P-exposed RPE in the present study revealed distinct regions where the induced events lie and that the positions of these regions are found at increasing distances from the optic nerve the later the time of exposure. This position effect directly reflects the previously observed developmental pattern of the RPE, namely that cells in the regions most distal from the optic nerve are proliferating most vigorously. The numbers and positions of RPE cells displaying the transformed (pigmented) phenotype strongly advocate the proposal that dividing cells are at highest risk to deletions induced by carcinogens.
Effectiveness of timely intraoperative iodine irrigation during cataract surgery.
Matsuura, Kazuki; Miyazaki, Dai; Sasaki, Shin-Ichi; Yakura, Keiko; Inoue, Yoshitsugu; Sakamoto, Masako
2016-11-01
To determine the antiseptic efficacy of timely intraoperative iodine irrigation during cataract surgery. A total of 198 eyes of 99 cataract surgery patients were studied. The eyes were randomly assigned to treatment with or without timely intraoperative iodine irrigation of the surgical field with an iodine compound equivalent to 0.33 % povidone-iodine. In eyes in the timely intraoperative iodine irrigation group, the ocular surface was irrigated twice intraoperatively-before the initial incision and before insertion of the intraocular lens (IOL). The efficacy of the antiseptic treatment was evaluated by culture tests using scrapings of the surface of the sclerocornea and conjunctiva to the left of the incision and by broad-range real-time PCR for bacterial 16S ribosomal DNA using scrapings from the right side of the incision. Following intraoperative application of the iodine, bacteria were not detected in cultures of the samples. For the control eyes without timely iodine irrigation, cultures of samples from five and two eyes were positive before the initial incision and before IOL insertion, respectively. The bacterial DNA copy number before the initial incision was 1.7 ± 0.5 × 10 3 , which was significantly lower than that of the control eyes (1.7 ± 0.6 × 10 4 ). For both groups of eyes, the bacterial DNA copy number was significantly lower before the IOL insertion depending on the time course. When the antiseptic effect of the iodine irrigation and time course on bacterial DNA copy number was analyzed using generalized mixed linear regression, both were found to be significantly effective. No significant intraoperative epithelial defect was observed. The postoperative corneal endothelial cell count did not differ significantly between the two groups of eyes. Timely iodine irrigation can serve as a simple and useful adjunctive disinfection step in cataract surgery.
Ciliary Muscle Thickness in Anisometropia
Kuchem, Mallory K; Sinnott, Loraine T; Kao, Chiu-Yen; Bailey, Melissa D
2014-01-01
Purpose The purpose of this study was to investigate the relationships between ciliary muscle thickness (CMT), refractive error, and axial length both across subjects and between the more and less myopic eyes of adults with anisometropia. Methods Both eyes of 29 adult subjects with at least 1.00 D of anisometropia were measured. Ciliary muscle thickness was measured at the maximum thickness (CMTMAX) and at 1.0 mm (CMT1), 2.0 mm (CMT2), and 3.0 mm (CMT3) posterior to the scleral spur, and also at the apical region (Apical CMTMAX = CMTMAX – CMT2, and Apical CMT1 = CMT1 – CMT2). Multilevel regression models were used to determine the relationship between the various CMT measures and cycloplegic refractive error or axial length, and to assess whether there are CMT differences between the more and less myopic eyes of an anisometropic adult. Results CMTMAX, CMT1, CMT2 and CMT3 were negatively associated with mean refractive error (all p ≤ 0.03), and the strongest association was in the posterior region (CMT2 and CMT3). Apical CMTMAX and Apical CMT1, however, were positively associated with mean refractive error (both p < 0.0001) across subjects. Within a subject, i.e., comparing the two anisometropic eyes, there was no statistically significant difference in CMT in any region. Conclusions Similar to previous studies, across anisometropic subjects, a thicker posterior region of the ciliary muscle (CMT2 and CMT3) was associated with increased myopic refractive error. Conversely, shorter, more hyperopic eyes tended to have thicker anterior, apical fiber portions of their ciliary muscle (Apical CMTMAX and Apical CMT1). There was no difference between the two eyes for any CMT measurement, indicating that in anisometropia, an eye can grow longer and more myopic than its fellow eye without resulting in an increase in CMT. PMID:24100479
... a defect in, the control of voluntary purposeful eye movement. Children with this condition have difficulty moving their ... to compensate for this inability to initiate horizontal eye movements away from the straight-ahead gaze position. Typically, ...
Lee, Sun Young; Cheng, Vincent; Rodger, Damien; Rao, Narsing
2015-12-01
Ocular syphilis is reemerging as an important cause of uveitis in the new era of common co-infection with HIV. This study will reveal the clinical and laboratory characteristics in the group of individuals co-infected with ocular syphilis and HIV compared with HIV-negative individuals. In this retrospective observational case series, medical records of patients diagnosed with ocular syphilis with serologic support from 2008 to 2014 were reviewed. Ocular and systemic manifestation and laboratory profiles were reviewed. Twenty-nine eyes of 16 consecutive patients (10 HIV-positive and 6 HIV-negative) were included. All patients were males, and mean age of onset for ocular syphilis was 43 (mean 42.65 ± 13.13). In both HIV-positive and HIV-negative groups, ocular manifestations of syphilis were variable including anterior uveitis (4 eyes), posterior uveitis (8 eyes), panuveitis (13 eyes), and isolated papillitis (4 eyes). In HIV-positive patients, panuveitis was the most common feature (12/18 eyes, 67 %) and serum rapid plasma reagin (RPR) titers were significantly higher (range 1:64-1:16,348; mean 1:768; p = 0.018) than in HIV-negative patients. Upon the diagnosis of ocular syphilis in HIV-positive patients, HIV-1 viral load was high (median 206,887 copies/ml) and CD4 cell count ranged from 127 to 535 cells/ml (mean 237 ± 142; median 137). Regardless of HIV status, cerebrospinal fluid (CSF) exam was frequently abnormal: positive CSF fluorescent treponemal antibody absorption (FTA-ABS) or Venereal Disease Research Laboratory (VDRL) test results in seven patients or either elevated CSF WBC count or elevated CSF protein in six patients. Our results reveal that the patients with ocular syphilis with high serum RPR titers may have concomitant HIV infection requiring further testing for HIV status and ocular syphilis is likely associated with the central nervous system involvement and therefore needs to be managed according to the treatment recommendations for neurosyphilis.
Association between positive corneal rim cultures and microbiology screening protocols in Ontario.
Sharma, Rahul A; Park, John S Y; Wang, Yao; Zhang, Tinghua; Sharpen, Linda; Dixon, William; Mather, Rookaya
2018-06-01
(i) To assess the rate of positive microbiological cultures of corneas prepared by the Eye Bank of Canada (Ontario Division) between January 1, 2012, and December 31, 2013; (ii) to review the microbiology protocols at the 5 major transplant centres in Ontario; and (iii) to assess the incidence of endophthalmitis during the study period. Retrospective chart review. A total of 4186 consecutive cultured corneal tissues prepared by the Eye Bank from January 1, 2012, to December 31, 2013. Rates of culture-positive cornea rims and incidence of postkeratoplasty endophthalmitis at 5 surgical centres in Ontario were determined, and the protocols used to culture rims at each site were concurrently reviewed. Culture results were analyzed via logistic regression for positive cultures. The rate of positive cultures at each sites were as follows: centre A, 3.74%; centre B, 3.26%; centre C, 0.51%; centre D, 0.48%; and centre E, 0.04%. Centres A, B, and D were noted to have significantly higher positive rates than centre E. In comparing microbiology protocols, longer incubation period (11 days) was 12 times more likely to be associated with higher positive culture rates than shorter period (4-5 days). Six-month follow-up of all keratoplasties revealed zero reported cases of endophthalmitis. A literature review regarding the predictive value of routine culturing reveals conflicting data. Our findings suggest that differences in the microbiology protocols directly influence the rates of positive rim cultures. Without a standardized protocol, it is not possible to evaluate the predictive value of routine corneal rim culturing in predicting postkeratoplasty endophthalmitis. Copyright © 2018. Published by Elsevier Inc.
Yamada, T; Suzuki, D A; Yee, R D
1996-11-01
1. Smooth pursuitlike eye movements were evoked with low current microstimulation delivered to rostral portions of the nucleus reticularis tegmenti pontis (rNRTP) in alert macaques. Microstimulation sites were selected by the observation of modulations in single-cell firing rates that were correlated with periodic smoothpursuit eye movements. Current intensities ranged from 10 to 120 microA and were routinely < 40 microA. Microstimulation was delivered either in the dark with no fixation, 100 ms after a fixation target was extinguished, or during maintained fixation of a stationary or moving target. Evoked eye movements also were studied under open-loop conditions with the target image stabilized on the retina. 2. Eye movements evoked in the absence of a target rapidly accelerated to a constant velocity that was maintained for the duration of the microstimulation. Evoked eye speeds ranged from 3.7 to 23 deg/s and averaged 11 deg/s. Evoked eye speed appeared to be linearly related to initial eye position with a sensitivity to initial eye position that averaged 0.23 deg.s-1.deg-1. While some horizontal and oblique smooth eye movements were elicited, microstimulation resulted in upward eye movements in 89% of the sites. 3. Evoked eye speed was found to be dependent on microstimulation pulse frequency and current intensity. Within limits, evoked eye speed increased with increases in stimulation frequency or current intensity. For stimulation frequencies < 300-400 Hz, only smooth pursuit-like eye movements were evoked. At higher stimulation frequencies, accompanying saccades consistently were elicited. 4. Feedback of retinal image motion interacted with the evoked eye movements to decrease eye speed if the visual motion was in the opposite direction as the evoked, pursuit-like eye movements. 5. The results implicate rNRTP as part of the neuronal substrate that controls smooth-pursuit eye movements. NRTP appears to be divided functionally into a rostral, pursuit-related portion and a caudal, saccade-related area. rNRTP is a component of a corticopontocerebellar circuit that presumably involves the pursuit area of the frontal eye field and that parallels the middle and medial superior temporal cerebral cortical/dorsalateral pontine nucleus (MT/MST-DLPN-cerebellum) pathway known to be involved also with regulating smooth-pursuit eye movements.
Effects of aircraft windscreens and canopies on HMT/D aiming accuracy: III
NASA Astrophysics Data System (ADS)
Task, H. Lee; Goodyear, Chuck
1999-07-01
Modern fighter aircraft windscreens and canopies are typically made of curved, transparent plastic for improved aero-dynamics and bird-strike protection. Since they are curved these transparencies often refract light in such a way that a pilot looking through the transparency will see a target in a location other than where it really is. This effect has been known for many years and methods to correct the aircraft head- up display (HUD) for these angular deviations have been developed and employed. The same problem occurs for helmet- mounted display/trackers (HMD/Ts) used for target acquisition. However, in this case, the pilot can look through any part of the transparency instead of being constrained to just the forward section as in the case of the HUD and his/her head position can be anywhere in a rather large motion box. To explore the magnitude of these aiming errors several F-15, F- 16, F-18, and F-22 transparency systems were measured from a total of 12 different eye positions centered around the HMD Eye (the HMD Eye was defined to be a point 1.25 inches to the right of the aircraft Design Eye). The collection of eye points for assessing HMT/D aiming accuracy were: HMD Eye, 3 inches left and right of HMD Eye, 2 inches above HMD Eye, and 2 inches forward of HMD Eye plus all combinations of these. Results from these measurements along with recommendations regarding means of assessing 'goodness' of correction algorithms are presented.
Quality of life of eye amputated patients.
Rasmussen, Marie L R; Ekholm, Ola; Prause, Jan U; Toft, Peter B
2012-08-01
To evaluate eye-amputated patients' health-related quality of life, perceived stress, self-rated health, job separation because of illness or disability and socioeconomic position. Patients were recruited from a tertiary referral centre situated in Copenhagen. Inclusion criteria were eye amputation, i.e. evisceration, enucleation, orbital exenteration or secondary implantation of an orbital implant during the period 1996-2003, and participation in a previous investigation (2005). In total, 159 eye-amputated patients were included, and completed a self-administered questionnaire containing health-related quality of life (SF-36), the perceived stress scale and answered questions about self-rated health, job changes because of illness or disability and socioeconomic status. These results were compared with findings from the Danish Health Interview Survey 2005. The eye-amputated patients had significantly (p < 0.05) lower scores (poorer health) on all SF-36 subscales and more perceived stress compared to the general population. In all, 43.3% of the patients rated their health as excellent or very good compared to 52.1% of the general population. In total, 25% of the study population has retired or changed to a part-time job because of eye disease. The percentage of eye amputated patients, who were divorced or separated, was twice as high as in the general population. The impact of an eye amputation is considerable. The quality of life, perceived stress and self-rated health of many eye-amputated patients are drastically changed. Eye amputation has a marked negative influence on job separation because of illness or disability and on socioeconomic position. © 2011 The Authors. Acta Ophthalmologica © 2011 Acta Ophthalmologica Scandinavica Foundation.
Likelihood Ratios for Glaucoma Diagnosis Using Spectral Domain Optical Coherence Tomography
Lisboa, Renato; Mansouri, Kaweh; Zangwill, Linda M.; Weinreb, Robert N.; Medeiros, Felipe A.
2014-01-01
Purpose To present a methodology for calculating likelihood ratios for glaucoma diagnosis for continuous retinal nerve fiber layer (RNFL) thickness measurements from spectral domain optical coherence tomography (spectral-domain OCT). Design Observational cohort study. Methods 262 eyes of 187 patients with glaucoma and 190 eyes of 100 control subjects were included in the study. Subjects were recruited from the Diagnostic Innovations Glaucoma Study. Eyes with preperimetric and perimetric glaucomatous damage were included in the glaucoma group. The control group was composed of healthy eyes with normal visual fields from subjects recruited from the general population. All eyes underwent RNFL imaging with Spectralis spectral-domain OCT. Likelihood ratios for glaucoma diagnosis were estimated for specific global RNFL thickness measurements using a methodology based on estimating the tangents to the Receiver Operating Characteristic (ROC) curve. Results Likelihood ratios could be determined for continuous values of average RNFL thickness. Average RNFL thickness values lower than 86μm were associated with positive LRs, i.e., LRs greater than 1; whereas RNFL thickness values higher than 86μm were associated with negative LRs, i.e., LRs smaller than 1. A modified Fagan nomogram was provided to assist calculation of post-test probability of disease from the calculated likelihood ratios and pretest probability of disease. Conclusion The methodology allowed calculation of likelihood ratios for specific RNFL thickness values. By avoiding arbitrary categorization of test results, it potentially allows for an improved integration of test results into diagnostic clinical decision-making. PMID:23972303
Ishii, Youhei; Morita, Kiichiro; Shouji, Yoshihisa; Nakashima, Youko; Uchimura, Naohisa
2010-02-01
Emotion-associated sounds have been suggested to exert important effects upon human personal relationships. The present study was aimed to characterize the effects of the sounds of crying or laughing on visual cognitive function in schizophrenia patients. We recorded exploratory eye movements in 24 schizophrenia patients (mean age, 27.0 +/- 6.1 years; 14 male, 10 female) and age-matched controls. The total eye scanning length (TESL) and total number of gaze points in the left (left TNGP) and right (right TNGP) visual fields of the screen and the number of researching areas (NRA) were determined using eye-mark recording in the presence/absence of emotionally charged sounds. Controls' TESL for smiling pictures was longer than that for crying pictures irrespective of sounds. Patients' TESL for smiling pictures, however, was shorter than for crying pictures irrespective of the sounds. The left TNGP for smiling pictures was lower in patients than controls independent of sound. Importantly, the right TNGP was significantly larger with laughing sounds than in the absence of sound. In controls, the NRA for smiling pictures was significantly greater than for crying pictures irrespective of sound. Patient NRA did not significantly differ between smiling and crying pictures irrespective of sound. Eye movements in schizophrenia patients' left field for smiling pictures associated with laughing sounds particularly differed from those in controls, suggesting impaired visual cognitive function associated with positive emotion, also involving pleasure-related sounds, in schizophrenia.
Ilechie, Alex; Abokyi, Samuel; Boateng, Gifty; Koffuor, George Asumeng
2016-01-01
Background: Preserved versus nonpreserved formulations for ophthalmic use have been well described in the literature although not specifically in the African population where beta blockers are frequently used as the first-line therapy due to economic and availability issues. This study sought to determine the effect of preserved and preservative-free Timolol eye drops on tear film stability in healthy black Africans. Materials and Methods: Sixty healthy nondry eye subjects aged 19–25 years were randomly assigned into four groups (n = 15) and differently treated with eye drops of phosphate buffered saline (PBS), preservative-free timolol (PFT), benzalkonium chloride (BAK) only, and BAK-preserved timolol (BPT). Noninvasive tear break-up time (NITBUT) was measured using the keratometer at baseline and 30, 60, and 90 min after drop application. Results: No significant decline in NITBUT was observed following treatment with PFT and PBS. However, BAK treatment showed a positive time-dependent significant decline in NITBUT (P < 0.001) while a significant decline in the BPT-treated group was only found at 90 min (−3.52 s; P < 0.001). In comparison to the PFT-treated group, treatment with BAK and BPT showed significantly lower NITBUT (P < 0.001). Conclusion: BPT is associated with a significant decline in tear film stability in black Africans. This finding has implications in the management of glaucoma in patients with high-risk of dry eyes in this population. PMID:27226684
Hao, Jie; Zhen, Yi; Wang, Hao; Yang, Diya; Wang, Ningli
2014-01-01
To investigate the effect of lateral decubitus position (LDP) on nocturnal intraocular pressure (IOP) and the effect of LDP on 24-hour habitual IOP pattern in healthy subjects. Intraocular pressure was measured every 2-hours using an Accupen Applanation Tonometer (Accutome, USA). During the diurnal period (7:30 am, 9:30 am, 11:30 am, 1:30 pm, 3:30 pm, 5:30 pm, 7:30 pm, and 9:30 pm), IOP was measured in the sitting position under bright light (500-1000 lux) after the subjects had been seated for 5 min. The nocturnal IOP was measured in the supine position, right LDP, and left LDP, with randomized sequences, under dim light (<10 lux) at 11:30 pm, 1:30 am, 3:30 am, and 5:30 am. The subjects were awakened and maintained each position for 5 min before the measurement. The 24-hour habitual IOP patterns were obtained according to the nocturnal position (supine, right LDP and left LDP) for either eye. P<0.05 was considered to be significant. Nineteen healthy subjects were included with a mean age of 51.3±5.8 years. During the nocturnal period, a significant IOP difference was found between the dependent eye (the eye on the lower side) of LDP and the supine position, but not for all the nocturnal time points. Over a 24-hour period, the effect of LDP on habitual IOP pattern was not statistically significant, although the mean nocturnal IOP and the diurnal-nocturnal IOP change for the right and the left eye in the LDP pattern was slightly higher than that in the sitting-supine pattern. Significant nocturnal IOP differences existed between the dependent eye and the supine, but did not occur consistently for all time points. Over a 24-hour period, the effect of LDP on habitual IOP pattern was not statistically significant in healthy subjects.
A Microcomputer-Based Software Package for Eye-Monitoring Research. Technical Report No. 434.
ERIC Educational Resources Information Center
McConkie, George W.; And Others
A software package is described that collects and reduces eye behavior data (eye position and pupil size) using an IBM-PC compatible computer. Written in C language for speed and portability, it includes several features: (1) data can be simultaneously collected from other sources (such as electroencephalography and electromyography); (2)…
Initial Scene Representations Facilitate Eye Movement Guidance in Visual Search
ERIC Educational Resources Information Center
Castelhano, Monica S.; Henderson, John M.
2007-01-01
What role does the initial glimpse of a scene play in subsequent eye movement guidance? In 4 experiments, a brief scene preview was followed by object search through the scene via a small moving window that was tied to fixation position. Experiment 1 demonstrated that the scene preview resulted in more efficient eye movements compared with a…
Delgado-Garcia, J M; Evinger, C; Escudero, M; Baker, R
1990-08-01
1. The activity of both accessory abducens (Acc Abd) and abducens (Abd) motoneurons (Mns) was recorded in the alert cat during eye retraction and rotational eye movements. Cats were fitted with two scleral coils, one measured rotational eye movements directly and the other retraction by distinguishing the translational component. 2. Acc Abd and Abd Mns were identified following antidromic activation from electrical stimulation of the ipsilateral VIth nerve. 3. In response to corneal air puffs, bursts of spikes were produced in all (n = 30) Acc Abd Mns. The burst began 7.2 +/- 1.2 (SD) ms after onset of the air puff and 8.9 +/- 1.9 ms before eye retraction. 4. Acc Abd Mns were silent throughout all types of rotational eye movements, and tonic activity was not observed during intervals without air-puff stimulation. 5. In contrast, all (n = 50) identified Abd Mns exhibited a burst and/or pause in activity preceding and during horizontal saccades as well as a tonic activity proportional to eye position. 6. Only 10% of Abd Mns fired a weak burst of spikes in response to air-puff stimulation. 7. We conclude that Acc Abd Mns are exclusively involved in eye retraction in the cat and that only a few Abd Mns have an eye-retraction signal added to their eye position and velocity signals. Thus any rotational eye-movement response described in retractor bulbi muscle must result from innervation by Mns located in the Abd and/or the oculomotor nuclei. 8. The organization of the prenuclear circuitry and species variation are discussed in view of the nictiating membrane extension response measured in associative learning.
Wang, X L; Wang, Z J; Tang, L; Cao, W W; Sun, X H
2017-02-11
Objective: To evaluate the usefulness of albumin correction in determination of cytomegalovirus IgG in the aqueous humor of Posner-Schlossman syndrome (PSS) patients. Methods: Cases series studies. Forty-two patients (26 men and 16 women) who were diagnosed as PSS were enrolled from Oct. 2009 to Oct. 2015 at the Eye and ENT Hospital. During the same period, 20 patients with primary open-angle glaucoma (POAG) and 30 patients with bacterial endophthalmitis or retinal necrosis were enrolled as negative control group and inflammatory disease control group, respectively. Aqueous humor and serum samples were assayed to detect CMV IgG by enzyme-linked immunosorbent assay (ELISA), and albumin by scattering immunonephelometry. CMV DNA in aqueous humor was assayed by polymerase chain reaction (PCR). The ratio which was calculated as the (aqueous humor CMV IgG/serum CMV IgG)/(aqueous humor concentration of albumin/serum albumin concentration) over 0.6 was considered as intraocular antibody formation. Performance of differentiating control eyes from eyes with CMV-positive PSS was evaluated by the receiver operating characteristic curve. The ANOVA test, Mann-Whitney test and Chi-square test were performed to compare the differences among groups. Results: The detectable rate of CMV IgG antibody in the aqueous humor was 76.2%, 100.0% and 10.0% in PSS, inflammatory disease control and POAG groups, respectively. The levels of CMV IgG antibody in the PSS groups were significantly higher than that of POAG groups ( Z= 4.23, P< 0.001).The positive rate corrected by the albumin was 71.4%, 3.3% and 0.0%.The corrected positive rate in PSS groups was significantly higher than that of the inflammatory disease control and POAG groups (χ(2)=30.38, P< 0.01; χ(2)= 24.89, P< 0.01), with a sensitivity of 75.0% and a specificity of 98.0%. The area under the curve for calibrated ratio was 0.942 (95% CI : 0.859 to 0.984) which was higher than that of CMV IgG ( Z= 6.19, P< 0.001).The corrected positive rate of CMV IgG antibody (71.4%) was higher than that of CMV DNA (47.6%, χ(2)=4.003, P= 0.045). Conclusions: CMV IgG antibody ratio which was corrected by aqueous humor and serum albumin could effectively improve aqueous antibody specificity in PSS patients. Furthermore, CMV IgG antibody ratio combined with PCR could improve the sensitivity of CMV detection. All of which help clarify the CMV infection in PSS in CMV DNA negative eyes. (Chin J Ophthalmol, 2017, 53: 104-108) .
Heterophoria and fixation disparity: a review.
Kommerell, G; Gerling, J; Ball, M; de Paz, H; Bach, M
2000-06-01
Heterophoria does not provide a reliable clue for ordering prisms in an asthenopic patient. The same reservation applies to associated phoria, as determined by prism correction of fixation disparity. Subjective tests for fixation disparity, even those with a fusionable fixation target, do not correctly indicate the vergence position of the eyes under natural viewing conditions. Attempts to measure fixation disparity on the basis of stereo disparity, using the "Measuring and Correction Methods of H.-J. Haase", have failed.
Otolith-Canal Convergence In Vestibular Nuclei Neurons
NASA Technical Reports Server (NTRS)
Dickman, J. David; Si, Xiao-Hong
2002-01-01
The current final report covers the period from June 1, 1999 to May 31, 2002. The primary objective of the investigation was to determine how information regarding head movements and head position relative to gravity is received and processed by central vestibular nuclei neurons in the brainstem. Specialized receptors in the vestibular labyrinths of the inner ear function to detect angular and linear accelerations of the head, with receptors located in the semicircular canals transducing rotational head movements and receptors located in the otolith organs transducing changes in head position relative to gravity or linear accelerations of the head. The information from these different receptors is then transmitted to central vestibular nuclei neurons which process the input signals, then project the appropriate output information to the eye, head, and body musculature motor neurons to control compensatory reflexes. Although a number of studies have reported on the responsiveness of vestibular nuclei neurons, it has not yet been possible to determine precisely how these cells combine the information from the different angular and linear acceleration receptors into a correct neural output signal. In the present project, rotational and linear motion stimuli were separately delivered while recording responses from vestibular nuclei neurons that were characterized according to direct input from the labyrinth and eye movement sensitivity. Responses from neurons receiving convergent input from the semicircular canals and otolith organs were quantified and compared to non-convergent neurons.
Solar glare hazard analysis tool on account of determined points of time
Ho, Clifford K; Sims, Cianan Alexander
2014-09-23
Technologies pertaining to determining when glare will be perceived by a hypothetical observer from a glare source and the intensity of glare that will be perceived by the hypothetical observer from the glare source are described herein. A first location of a potential source of solar glare is received, and a second location of the hypothetical observer is received. Based upon such locations, including respective elevations, and known positions of the sun over time, a determination as to when the hypothetical observer will perceive glare from the potential source of solar glare is made. Subsequently, an amount of irradiance entering the eye of the hypothetical observer is calculated to assess potential ocular hazards.
Ueda, Sayoko; Kumagai, Gaku; Otaki, Yusuke; Yamaguchi, Shinya; Kohshima, Shiro
2014-01-01
As facial color pattern around the eyes has been suggested to serve various adaptive functions related to the gaze signal, we compared the patterns among 25 canid species, focusing on the gaze signal, to estimate the function of facial color pattern in these species. The facial color patterns of the studied species could be categorized into the following three types based on contrast indices relating to the gaze signal: A-type (both pupil position in the eye outline and eye position in the face are clear), B-type (only the eye position is clear), and C-type (both the pupil and eye position are unclear). A-type faces with light-colored irises were observed in most studied species of the wolf-like clade and some of the red fox-like clade. A-type faces tended to be observed in species living in family groups all year-round, whereas B-type faces tended to be seen in solo/pair-living species. The duration of gazing behavior during which the facial gaze-signal is displayed to the other individual was longest in gray wolves with typical A-type faces, of intermediate length in fennec foxes with typical B-type faces, and shortest in bush dogs with typical C-type faces. These results suggest that the facial color pattern of canid species is related to their gaze communication and that canids with A-type faces, especially gray wolves, use the gaze signal in conspecific communication.
Zang, Pengxiao; Gao, Simon S; Hwang, Thomas S; Flaxel, Christina J; Wilson, David J; Morrison, John C; Huang, David; Li, Dengwang; Jia, Yali
2017-03-01
To improve optic disc boundary detection and peripapillary retinal layer segmentation, we propose an automated approach for structural and angiographic optical coherence tomography. The algorithm was performed on radial cross-sectional B-scans. The disc boundary was detected by searching for the position of Bruch's membrane opening, and retinal layer boundaries were detected using a dynamic programming-based graph search algorithm on each B-scan without the disc region. A comparison of the disc boundary using our method with that determined by manual delineation showed good accuracy, with an average Dice similarity coefficient ≥0.90 in healthy eyes and eyes with diabetic retinopathy and glaucoma. The layer segmentation accuracy in the same cases was on average less than one pixel (3.13 μm).
Zang, Pengxiao; Gao, Simon S.; Hwang, Thomas S.; Flaxel, Christina J.; Wilson, David J.; Morrison, John C.; Huang, David; Li, Dengwang; Jia, Yali
2017-01-01
To improve optic disc boundary detection and peripapillary retinal layer segmentation, we propose an automated approach for structural and angiographic optical coherence tomography. The algorithm was performed on radial cross-sectional B-scans. The disc boundary was detected by searching for the position of Bruch’s membrane opening, and retinal layer boundaries were detected using a dynamic programming-based graph search algorithm on each B-scan without the disc region. A comparison of the disc boundary using our method with that determined by manual delineation showed good accuracy, with an average Dice similarity coefficient ≥0.90 in healthy eyes and eyes with diabetic retinopathy and glaucoma. The layer segmentation accuracy in the same cases was on average less than one pixel (3.13 μm). PMID:28663830
Conjunctival Flora of Human Immunodeficiency Virus Patients on Antiretroviral Treatment.
Giles, Kagmeni; Bilong, Yannick; Dohvoma, Andin Viola; Ebana, Steve Robert; Gonsu, Hortance
2017-01-01
To determine the conjunctival flora of human immunodeficiency virus (HIV) patients on antiretroviral treatment (ART). A total of 104 conjunctival swabs from 104 HIV patients on ART underwent microbiological evaluation to describe the flora. There were 71 (68.26%) women and 33 (31.74%) men. The mean age was 42.9 ± 9.77 (range: 22-70) years. Negative cultures were found in 39 (37.50%) cases. Bacterial growth occurred in 65 (62.50%) cases. Coagulase-negative Staphylococcus was found in 59 eyes (90.76%), and coagulase-positive in 3 eyes (4.61%). There was a significant correlation between the duration of ART, the degrees of immunosuppression, and bacterial growth. Knowledge of the conjunctival flora in HIV patients may provide a better guideline in the choice of antibiotic for the management of ocular surface infections.
Ultrasonographic biometry of the normal eye of the Persian cat.
Mirshahi, A; Shafigh, S H; Azizzadeh, M
2014-07-01
To describe the normal ultrasonographic biometry of the Persian cat's eyes using B-mode ultrasonography. In a cross-sectional study, 20 healthy Persian cats with no history of previous ophthalmic disease were examined. Ocular biometry of the left and right eyes was measured using B-mode ultrasonography. Comparison of the average measurements between left and right eyes and between vertical and horizontal planes was performed using paired-sample t test. Correlation of ocular parameters with sex, age, head circumference and eye colour was evaluated. Mean ± standard deviation (SD) measurements of the ocular structures of anterior chamber, lens thickness, vitreous chamber and anterior to posterior dimension of the globe in 40 eyes were 4.1 ± 0.7, 7.7 ± 0.5, 8.2 ± 0.4 and 20.7 ± 1.0 mm, respectively. No significant difference was found between the ocular biometry of the left and right eyes or the horizontal and vertical planes. Of the ocular parameters, the following had a significant positive correlation with head circumference: axial globe length, anterior chamber and lens thickness. The vitreous body had a positive correlation with age. Regarding the breed predisposition of Persian cats to ocular problems, the present study provides baseline information for further clinical investigations of ocular abnormalities using B-mode ultrasonography. © 2014 Australian Veterinary Association.
Instrument Display Visual Angles for Conventional Aircraft and the MQ-9 Ground Control Station
NASA Technical Reports Server (NTRS)
Kamine, Tovy Haber; Bendrick, Gregg A.
2008-01-01
Aircraft instrument panels should be designed such that primary displays are in optimal viewing location to minimize pilot perception and response time. Human Factors engineers define three zones (i.e. cones ) of visual location: 1) "Easy Eye Movement" (foveal vision); 2) "Maximum Eye Movement" (peripheral vision with saccades), and 3) "Head Movement (head movement required). Instrument display visual angles were measured to determine how well conventional aircraft (T-34, T-38, F- 15B, F-16XL, F/A-18A, U-2D, ER-2, King Air, G-III, B-52H, DC-10, B747-SCA) and the MQ-9 ground control station (GCS) complied with these standards, and how they compared with each other. Selected instrument parameters included: attitude, pitch, bank, power, airspeed, altitude, vertical speed, heading, turn rate, slip/skid, AOA, flight path, latitude, longitude, course, bearing, range and time. Vertical and horizontal visual angles for each component were measured from the pilot s eye position in each system. The vertical visual angles of displays in conventional aircraft lay within the cone of "Easy Eye Movement" for all but three of the parameters measured, and almost all of the horizontal visual angles fell within this range. All conventional vertical and horizontal visual angles lay within the cone of Maximum Eye Movement. However, most instrument vertical visual angles of the MQ-9 GCS lay outside the cone of Easy Eye Movement, though all were within the cone of Maximum Eye Movement. All the horizontal visual angles for the MQ-9 GCS were within the cone of "Easy Eye Movement". Most instrument displays in conventional aircraft lay within the cone of Easy Eye Movement, though mission-critical instruments sometimes displaced less important instruments outside this area. Many of the MQ-9 GCS systems lay outside this area. Specific training for MQ-9 pilots may be needed to avoid increased response time and potential error during flight. The learning objectives include: 1) Know three physiologic cones of eye/head movement; 2) Understand how instrument displays comply with these design principles in conventional aircraft and an uninhabited aerial vehicle system. Which of the following is NOT a recognized physiologic principle of instrument display design? Cone of Easy Eye Movement 2) Cone of Binocular Eye Movement 3) Cone of Maximum Eye Movement 4) Cone of Head Movement 5) None of the above. Answer: # 2) Cone of Binocular Eye Movement
Onerci Celebi, Ozlem; Celebi, Ali Riza Cenk
2018-04-09
The aim of this study was to investigate the effect of topically applied ocular anesthetic proparacaine on conjunctival and nasal bacterial mucosal flora in patients with dry eye disease. A Schirmer test was done with (group 1) and without (group 2) topical anesthetic proparacaine to 40 patients in each group. Conjunctival and nasal cultures were obtained before and 10 min after performing the Schirmer test. The bacterial culture results and the isolated bacteria were recorded in two groups. Patients' mean age was 62 years (70 female, 10 male). Before the application of topical anesthetic, 50 (62.5%) and 62 (77.5%) had positive conjunctival and nasal culture, respectively, with the most commonly isolated organism being coagulase-negative Staphylococcus in each group. In group 1 the conjunctival bacterial culture positivity rate decreased from 26 (65%) to six (15%) eyes ( p < 0.001); however, this rate decreased slightly from 24 (60%) to 20 (50%) eyes in group 2 ( p > 0.05). For the nasal cultures, the bacterial culture positivity rate decreased from 80% to 20% and from 75% to 65% in groups 1 ( p < 0.001) and 2 ( p > 0.05), respectively. Topical ocular anesthetic proparacaine has antibacterial activity in both conjunctival and nasal flora in patients with dry eye disease.
The Handicapped Can Dance Too!
ERIC Educational Resources Information Center
Lloyd, Marcia L.
1978-01-01
A program of dance therapy activities can offer handicapped individuals positive experiences in such areas as body image, spatial awareness, self-confidence, hand-eye/foot-eye coordination, visual focusing, balance and social relations. (Author/MJB)
Prevalence and phenomenology of eye tics in Gilles de la Tourette syndrome.
Martino, Davide; Cavanna, Andrea E; Robertson, Mary M; Orth, Michael
2012-10-01
Eye tics seem to be common in Gilles de la Tourette syndrome (GTS). We analyzed the frequency and clinical characteristics of eye tics in 212 GTS patients. Of the 212 patients, 201 (94.8 %) reported eye tics in their life-time; 166 (78.3 %) reported eye movement tics (rolling eyes up/down, eyes looking sideways, staring), and 194 (91.5 %) eyelid/eyebrow movement tics (frowning, raising eyebrows, blinking or winking). Patients with eye movement tics were younger at age of GTS onset (7.1 ± 4 years) than those without (8.9 ± 6.8; p = 0.024). Tic severity positively correlated to lifetime history of eye and/or eyelid/eyebrow movement tics. Our data confirm that eye and eyelid/eyebrow movement tics are very common in GTS, and most patients have several types of eye tics over time. Eye tic phenomenology was similar in patients with or without co-morbidity. Eye tics are therefore likely to be a core feature of GTS and should be routinely evaluated in order to strengthen the clinician's confidence in diagnosing GTS.
Effects of oral sea buckthorn oil on tear film Fatty acids in individuals with dry eye.
Järvinen, Riikka L; Larmo, Petra S; Setälä, Niko L; Yang, Baoru; Engblom, Janne Rk; Viitanen, Matti H; Kallio, Heikki P
2011-09-01
Evaporative dry eye is associated with meibomian gland dysfunction and abnormalities of the tear film lipids. Dry eye is known to be affected positively by intake of linoleic and γ-linolenic acids and n-3 fatty acids. Oral sea buckthorn (Hippophaë rhamnoides) (SB) oil, which contains linoleic and α-linolenic acids and antioxidants, has shown beneficial effects on dry eye. The objective was to investigate whether supplementation with SB oil affects the composition of the tear film fatty acids in individuals reporting dry eye. One hundred participants were randomized to this parallel, double-blind, placebo-controlled study, which 86 of them completed. The participants daily consumed 2 g of SB or placebo oil for 3 months. Tear film samples were collected at the beginning, during, and at the end of the intervention and 1 to 2 months later. Tear film fatty acids were analyzed as methyl esters by gas chromatography. There were no group differences in the changes in fatty acid proportions during the intervention (branched-chain fatty acids: P = 0.49, saturated fatty acids: P = 0.59, monounsaturated fatty acids: P = 0.53, and polyunsaturated fatty acids: P = 0.16). The results indicate that the positive effects of SB oil on dry eye are not mediated through direct effects on the tear film fatty acids. Carotenoids and tocopherols in the oil or eicosanoids produced from the fatty acids of the oil may have a positive effect on inflammation and differentiation of the meibomian gland cells.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kruijf, Willy J.M. de, E-mail: kruijf.de.w@bvi.nl; Verstraete, Jan; Neustadter, David
2013-02-01
Purpose: To evaluate the performance and safety of a radiation therapy positioning system (RealEye) based on tracking a radioactive marker (Tracer) implanted in patients with localized prostate cancer. Methods and Materials: We performed a single-arm multi-institutional trial in 20 patients. The iridium-192 ({sup 192}Ir)-containing Tracer was implanted in the patient together with 4 standard gold seed fiducials. Patient prostate-related symptoms were evaluated with the International Prostate Symptom Score (IPSS) questionnaire. Computed tomography (CT) was performed for treatment planning, during treatment, and after treatment to evaluate the migration stability of the Tracer. At 5 treatment sessions, cone beam CT was performedmore » to test the positioning accuracy of the RealEye. Results: The Tracer was successfully implanted in all patients. No device or procedure-related adverse events occurred. Changes in IPSS scores were limited. The difference between the mean change in Tracer-fiducial distance and the mean change in fiducial-fiducial distance was -0.39 mm (95% confidence interval [CI] upper boundary, -0.22 mm). The adjusted mean difference between Tracer position according to RealEye and the Tracer position on the CBCT for all patients was 1.34 mm (95% CI upper boundary, 1.41 mm). Conclusions: Implantation of the Tracer is feasible and safe. Migration stability of the Tracer is good. Prostate patients can be positioned and monitored accurately by using RealEye.« less
de Kruijf, Willy J M; Verstraete, Jan; Neustadter, David; Corn, Benjamin W; Hol, Sandra; Venselaar, Jack L M; Davits, Rob J; Wijsman, Bart P; Van den Bergh, Laura; Budiharto, Tom; Oyen, Raymond; Haustermans, Karin; Poortmans, Philip M P
2013-02-01
To evaluate the performance and safety of a radiation therapy positioning system (RealEye) based on tracking a radioactive marker (Tracer) implanted in patients with localized prostate cancer. We performed a single-arm multi-institutional trial in 20 patients. The iridium-192 ((192)Ir)-containing Tracer was implanted in the patient together with 4 standard gold seed fiducials. Patient prostate-related symptoms were evaluated with the International Prostate Symptom Score (IPSS) questionnaire. Computed tomography (CT) was performed for treatment planning, during treatment, and after treatment to evaluate the migration stability of the Tracer. At 5 treatment sessions, cone beam CT was performed to test the positioning accuracy of the RealEye. The Tracer was successfully implanted in all patients. No device or procedure-related adverse events occurred. Changes in IPSS scores were limited. The difference between the mean change in Tracer-fiducial distance and the mean change in fiducial-fiducial distance was -0.39 mm (95% confidence interval [CI] upper boundary, -0.22 mm). The adjusted mean difference between Tracer position according to RealEye and the Tracer position on the CBCT for all patients was 1.34 mm (95% CI upper boundary, 1.41 mm). Implantation of the Tracer is feasible and safe. Migration stability of the Tracer is good. Prostate patients can be positioned and monitored accurately by using RealEye. Copyright © 2013 Elsevier Inc. All rights reserved.
Heritability of hair whorl position on the forehead in Konik horses.
Górecka, A; Słoniewski, K; Golonka, M; Jaworski, Z; Jezierski, T
2006-12-01
There are studies on the relationship between the position and shape of hair whorls on bovine forehead and phenotypic traits. According to anecdotal beliefs by horse users and handlers, temperamental traits may be related to the position of hair whorls in horses. No previous research on the mechanisms of inheritance of hair whorls has been performed, so the aim of the present study was to determine the heritability of the position of the hair whorl on the forehead of Konik horses. The horses (n = 362) were classified into five groups based on the whorl position on forehead with respect to the top and bottom eye lines. The estimated heritability of hair whorl position was 0.753 (SE = 0.056). Heritability adjusted for the discontinuity of the trait was 0.836. The results show that hair whorl position in Konik Polski horses is highly heritable. The possible relationship between position of hair whorls on the forehead and other morphological traits needs further research and should be interpreted with caution.
Perret, Patrick; Ducrot, Stéphanie
2010-08-01
In two experiments that we conducted with adult (Experiment 1) and child (Experiment 2) participants, we experimentally controlled the eyes' first fixation in the word using a variable viewing-position technique in a classical all-letter-coloring Stroop procedure. We explored the impact of initial-fixation position (optimal viewing position [OVP] vs. end of the word) on the magnitude of Stroop effects (both interference and facilitation). The results showed that both interference and facilitation effects were reduced when the first fixation was located at the end of the word rather than at the OVP. These data make a new contribution to the study of the role of low-level processes in Stroop effects and add support to the growing body of research indicating that oculomotor processes can act as moderators of cognitive processes in the determination of Stroop effects.
Effects of lenses with different power profiles on eye shape in chickens.
Tepelus, Tudor Cosmin; Vazquez, Daniel; Seidemann, Anne; Uttenweiler, Dietmar; Schaeffel, Frank
2012-02-01
Defocus imposed to the periphery of the visual field can affect the development of foveal/central refractive errors. To make use of this observation, lenses can be designed to reduce myopia progression, but it is important to know which power profiles of the lenses are most effective. We have studied this question in chickens. Sixty male white leghorn chickens were used. From day 7 after hatching, they were treated for 5 days either with full field -7D or +7D lenses, with -7D lenses with a 4mm central hole, with hemi-field lenses of the same power, or with two different types of radial refractive gradient (RRG) lenses with increasing positive power from the center to the periphery, which were designed by Rodenstock GmbH, Munich, Germany. A macro file was written for "ImageJ" to trace and average the outlines of several excised eyes after treatment. Shapes of fellow control eyes and lens-treated eyes were compared in the horizontal and vertical meridians. Refractions were determined at -45°, 0°, and 45° over the horizontal visual field, at the beginning and at the end of experiments, using automated infrared photoretinoscopy. (1) Eye length, as determined by the new automated eye shape tracing technique, was well correlated with A-scan ultrasound data. (2) The effects of previously tested lens designs were reproduced with the new tracing technique. Full field lenses were by far the most effective (-7D: external axial length +0.24mm with an increase in eye volume of about 6%, +7D: -0.08 mm, with a decrease in eye volume of about 2%). Hemi-field lenses and negative lenses with a 4mm central hole induced conspicuous local changes in eye shape. (3) The first type of RRG lenses with a plano zone of about 4mm (equivalent to about ± 12.52° in the visual field for a vertex distance of 5mm) had no apparent effect on central refractions but induced small hyperopic shifts in the periphery, more significant in the temporal retina (+1.70 ± 1.70 D, p<0.001, paired t-test to untreated fellow eyes). The second type of RRG lenses with a small plano zone of 2mm (equivalent to ± 6.34°) induced peripheral hyperopia but also changed the central refraction (temporal retina +1.50 ± 1.17D, p<0.001, central retina +0.77 ± 1.15 D, p<0.01, nasal retina +1.47±1.35D, p<0.001, paired t-test to untreated control eyes). In the afoveate chick, RRG lenses have an effect on central refraction and eye growth only if the central plano zone is small (<4mm). For the second type of RRG lens with a central plano zone of about 2mm, inhibitory effects on eye growth were detected in both the center and periphery even though the optical power of the lenses in the periphery was low. Copyright © 2011 Elsevier Ltd. All rights reserved.
McIlwain, J T
1990-03-01
Saccades evoked electrically from the deep layers of the superior colliculus have been examined in the alert cat with its head fixed. Amplitudes of the vertical and horizontal components varied linearly with the starting position of the eye. The slopes of the linear-regression lines provided an estimate of the sensitivity of these components to initial eye position. In observations on 29 sites in nine cats, the vertical and horizontal components of saccades evoked from a given site were rarely influenced to the same degree by initial eye position. For most sites, the horizontal component was more sensitive than the vertical component. Sensitivities of vertical and horizontal components were lowest near the representations of the horizontal and vertical meridians, respectively, of the collicular retinotopic map, but otherwise exhibited no systematic retinotopic dependence. Estimates of component amplitudes for saccades evoked from the center of the oculomotor range also diverged significantly from those predicted from the retinotopic map. The results of this and previous studies indicate that electrical stimulation of the cat's superior colliculus cannot yield a unique oculomotor map or one that is in register everywhere with the sensory retinotopic map. Several features of these observations suggest that electrical stimulation of the colliculus produces faulty activation of a saccadic control system that computes target position with respect to the head and that small and large saccades are controlled differently.
P gene as an inherited biomarker of human eye color.
Rebbeck, Timothy R; Kanetsky, Peter A; Walker, Amy H; Holmes, Robin; Halpern, Allan C; Schuchter, Lynn M; Elder, David E; Guerry, DuPont
2002-08-01
Human pigmentation, including eye color, has been associated with skin cancer risk. The P gene is the human homologue to the mouse pink-eye dilution locus and is responsible for oculocutaneous albinism type 2 and other phenotypes that confer eye hypopigmentation. The P gene is located on chromosome 15q11.2-q12, which is also the location of a putative eye pigmentation gene (EYCL3) inferred to exist by linkage analysis. Therefore, the P gene is a strong candidate for determination of human eye color. Using a sample of 629 normally pigmented individuals, we found that individuals were less likely to have blue or gray eyes if they had P gene variants Arg305Trp (P = 0.002), Arg419Gln (P = 0.001), or the combination of both variants (P = 0.003). These results suggest that P gene, in part, determines normal phenotypic variation in human eye color and may therefore represent an inherited biomarker of cutaneous cancer risk.
Role of the water-drinking test in medically treated primary open angle glaucoma patients.
Salcedo, H; Arciniega, D; Mayorga, M; Wu, L
2018-05-01
The water-drinking test (WDT) has recently re-emerged as a possible way to determine the competency of the trabecular meshwork. We performed a prospective interventional study to test the hypothesis that the WDT could be useful in assessing fluctuations in patients undergoing treatment for primary open angle glaucoma (POAG). We included 122 patients; 62 on medical treatment for POAG (n=123 eyes) and 60 controls (n=120 eyes). The study group had been on intraocular pressures (IOP) lowering treatment continuously for at least 3months with stable IOP. The WDT was performed during fasting and was considered positive if it fluctuated ≥6mmHg. The patients on medical treatment had a mean age of 50.56±18.45 years vs. 51.35±11.22 for the controls (P=0.34); with 71% being female in the study group and 77% in the control group. In the study group; 52% were on beta blockers (n=64), 27% combination of two or more medications (n=33), 19% prostaglandin analogues (n=24) and 2% alpha agonists (n=2). The WDT was positive in 17.07% (n=21) in the study group and 2.5% (n=3) in the control group (P=0.0001). The mean fluctuation was 7.14±2.15mmHg in the study group and 6.00±0mmHg in the controls (P=0.33). A positive WDT was found in 33.33% (n=11) of those on combination therapy; 12.5% (n=3) prostaglandin analogues and 10.94% (n=7) beta blockers (P=0.03). Combination therapy had the highest positive WDT fluctuation (7.54±2.87) followed by prostaglandin analogues (7.00±1.00) and beta blockers (6.57±0.78) with a P value of 0.44. The WDT can identify significant fluctuations in eyes with POAG that are medically treated. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
NASA Technical Reports Server (NTRS)
Dick, A. O.
1980-01-01
Eye movement data and other parameters including instrument readings, aircraft state and position variables, and control maneuvers were recorded while pilots flew ILS simulations in a B 737. The experiment itself employed seven airline pilots, each of whom flew approximately 40 approach/landing sequences. The simulator was equipped with a night visual scene but the scene was fogged out down to approximately 60 meters (200 ft). The instrument scanning appeared to follow aircraft parameters not physical position of instruments. One important implication of the results is: pilots look for categories or packets of information. Control inputs were tabulated according to throttle, wheel position, column, and pitch trim changes. Three seconds of eye movements before and after the control input were then obtained. Analysis of the eye movement data for the controlling periods showed clear patterns. The results suggest a set of miniscan patterns which are used according to the specific details of the situation. A model is developed which integrates scanning and controlling. Differentiations are made between monitoring and controlling scans.
Camachon, Cyril; Montagne, Gilles
2018-01-01
The present study addresses the effect of the eye position in the cockpit on the flight altitude during the final approach to landing. Three groups of participants with different levels of expertise (novices, trainees, and certified pilots) were given a laptop with a flight simulator and they were asked to maintain a 3.71° glide slope while landing. Each participant performed 40 approaches to the runway. During 8 of the approaches, the point of view that the flight simulator used to compute the visual scene was slowly raised or lowered with 4 cm with respect to the cockpit, hence moving the projection of the visible part of the cockpit down or up in the visible scene in a hardly noticeable manner. The increases and decreases in the simulated eye height led to increases and decreases in the altitude of the approach trajectories, for all three groups of participants. On the basis of these results, it is argued that the eye position of pilots during visual approaches is a factor that contributes to the risk of black hole accidents. PMID:29795618
Barsingerhorn, A D; Boonstra, F N; Goossens, H H L M
2017-02-01
Current stereo eye-tracking methods model the cornea as a sphere with one refractive surface. However, the human cornea is slightly aspheric and has two refractive surfaces. Here we used ray-tracing and the Navarro eye-model to study how these optical properties affect the accuracy of different stereo eye-tracking methods. We found that pupil size, gaze direction and head position all influence the reconstruction of gaze. Resulting errors range between ± 1.0 degrees at best. This shows that stereo eye-tracking may be an option if reliable calibration is not possible, but the applied eye-model should account for the actual optics of the cornea.
Gaze failure, drifting eye movements, and centripetal nystagmus in cerebellar disease.
Leech, J; Gresty, M; Hess, K; Rudge, P
1977-01-01
Three abnormalities of eye movement in man are described which are indicative of cerebellar system disorder, namely, centripetally beating nystagmus, failure to maintain lateral gaze either in darkness or with eye closure, and slow drifting movements of the eyes in the absence of fixation. Similar eye movement signs follow cerebellectomy in the primate and the cat. These abnormalities of eye movement, together with other signs of cerebellar disease, such as rebound alternating, and gaze paretic nystagmus, are explained by the hypothesis that the cerebellum helps to maintain lateral gaze and that brain stem mechanisms which monitor gaze position generate compensatory biases in the absence of normal cerebellar function. PMID:603785
Three-Dimensional Measurement Applied in Design Eye Point of Aircraft Cockpits.
Wang, Yanyan; Guo, Xiaochao; Liu, Qingfeng; Xiao, Huajun; Bai, Yu
2018-04-01
Inappropriate design eye point (DEP) will lead to nonstandard sitting postures, including nonneutral head positions and other uncomfortable sitting postures, which are high risk factors for neck pain in fighter pilots exposed to high G forces. Therefore, application of a 3D measurement method to collect data regarding eye position while in the cruising sitting posture in the aircraft cockpit to guide the design eye point has been proposed. A total of 304 male fixed wing aircraft pilots were divided into two groups. Subgroup A (N = 48) were studied to define the cruising posture during flight. Subgroup B (N = 256) were studied with Romer 3D measurement equipment to locate the cruising eye position of the pilots in a simulated cockpit. The 3D data were compared to DEP data in the current standard cockpit. According to 3D measurement, the vertical distance from the cruising eye point to the neutral seat reference point was 759 mm, which is 36 mm lower than that of the Chinese standard DEP and also lower than the U.S. military standard. The horizontal distance was 131 mm, which is 24 mm shorter than that of the Chinese standard. The current DEP data cannot fulfill the needs of fighter pilots and should be amended according to the results of the 3D measurement so that pilots can acquire the optimal cruising posture in flight. This new method has the value of practical application to investigate cockpit ergonomics and the measurement data can guide DEP design.Wang Y, Guo X, Liu Q, Xiao H, Bai Y. Three-dimensional measurement applied in design eye point of aircraft cockpits. Aerosp Med Hum Perform. 2018; 89(4):371-376.
Zetterberg, Camilla; Richter, Hans O.; Forsman, Mikael
2015-01-01
Near work is associated with increased activity in the neck and shoulder muscles, but the underlying mechanism is still unknown. This study was designed to determine whether a dynamic change in focus, alternating between a nearby and a more distant visual target, produces a direct parallel change in trapezius muscle activity. Fourteen healthy controls and 12 patients with a history of visual and neck/shoulder symptoms performed a Near-Far visual task under three different viewing conditions; one neutral condition with no trial lenses, one condition with negative trial lenses to create increased accommodation, and one condition with positive trial lenses to create decreased accommodation. Eye lens accommodation and trapezius muscle activity were continuously recorded. The trapezius muscle activity was significantly higher during Near than during Far focusing periods for both groups within the neutral viewing condition, and there was a significant co-variation in time between accommodation and trapezius muscle activity within the neutral and positive viewing conditions for the control group. In conclusion, these results reveal a connection between Near focusing and increased muscle activity during dynamic changes in focus between a nearby and a far target. A direct link, from the accommodation/vergence system to the trapezius muscles cannot be ruled out, but the connection may also be explained by an increased need for eye-neck (head) stabilization when focusing on a nearby target as compared to a more distant target. PMID:25961299
Zetterberg, Camilla; Richter, Hans O; Forsman, Mikael
2015-01-01
Near work is associated with increased activity in the neck and shoulder muscles, but the underlying mechanism is still unknown. This study was designed to determine whether a dynamic change in focus, alternating between a nearby and a more distant visual target, produces a direct parallel change in trapezius muscle activity. Fourteen healthy controls and 12 patients with a history of visual and neck/shoulder symptoms performed a Near-Far visual task under three different viewing conditions; one neutral condition with no trial lenses, one condition with negative trial lenses to create increased accommodation, and one condition with positive trial lenses to create decreased accommodation. Eye lens accommodation and trapezius muscle activity were continuously recorded. The trapezius muscle activity was significantly higher during Near than during Far focusing periods for both groups within the neutral viewing condition, and there was a significant co-variation in time between accommodation and trapezius muscle activity within the neutral and positive viewing conditions for the control group. In conclusion, these results reveal a connection between Near focusing and increased muscle activity during dynamic changes in focus between a nearby and a far target. A direct link, from the accommodation/vergence system to the trapezius muscles cannot be ruled out, but the connection may also be explained by an increased need for eye-neck (head) stabilization when focusing on a nearby target as compared to a more distant target.
Stride-Cycle Influences on Goal-Directed Head Movements Made During Walking
NASA Technical Reports Server (NTRS)
Peters, Brian T.; vanEmmerik, Richard E. A.; Bloomberg, Jacob J.
2006-01-01
Horizontal head movements were studied in six subjects as they made rapid horizontal gaze adjustments while walking. The aim of the present research was to determine if gait-cycle events alter the head movement response to a visual target acquisition task. Gaze shifts of approximately 40deg were elicited by a step change in the position of a visual target from a central location to a second location in the left or right horizontal periphery. The timing of the target position change was constrained to occur at 25,50,75 and 100% of the stride cycle. The trials were randomly presented as the subjects walked on a treadmill at their preferred speed (range: 1.25 to 1.48 m/s, mean: 1.39 +/- 0.09 m/s ) . Analyses focused on the movement onset latencies of the head and eyes and on the peak velocity and saccade amplitude of the head movement response. A comparison of the group means indicated that the head movement onset lagged the eye onset (262 ms versus 252 ms). The head and eye movement onset latencies were not affected by either the direction of the target change nor the point in the gait cycle during which the target relocation occurred. However, the presence of an interaction between the gait cycle events and the direction of the visual target shift indicates that the peak head saccade velocity and head saccade amplitude are affected by the natural head oscillations that occur while walking.
Clinical Features of Newly Diagnosed Cytomegalovirus Retinitis in Northern Thailand
Ausayakhun, Somsanguan; Keenan, Jeremy D; Ausayakhun, Sakarin; Jirawison, Choeng; Khouri, Claire M; Skalet, Alison H; Heiden, David; Holland, Gary N; Margolis, Todd P
2011-01-01
Purpose To characterize the clinical manifestations of cytomegalovirus (CMV) retinitis in northern Thailand. Design Prospective, observational cross-sectional study. Methods We recorded characteristics of 52 consecutive patients newly diagnosed with CMV retinitis at a tertiary university-based medical center in northern Thailand. Indirect ophthalmoscopy by experienced ophthalmologists was supplemented with fundus photography to determine the proportion of eyes with various clinical features of CMV retinitis. Results Of the 52 patients with CMV retinitis, 55.8% were female. All were HIV-positive. The vast majority (90.4%) had started antiretroviral therapy. CMV retinitis was bilateral in 46.2% of patients. Bilateral visual acuity worse than 20/60 was observed in 23.1% of patients. Of 76 eyes with CMV retinitis, 61.8% had zone I disease and 21.6% had lesions involving the fovea. Lesions larger than 25% of the retinal area were observed in 57.5% of affected eyes. CMV retinitis lesions commonly had marked or severe border opacity (47.4% of eyes). Vitreous haze was often present (46.1% of eyes). Visual impairment was more common in eyes with larger retinitis lesions. Retinitis lesion size, used as a proxy for duration of disease, was associated with fulminant appearance (OR 1.24 [1.01 – 1.51]), and marked or severe border opacity (OR 1.36 [1.11 – 1.67]). Based on lesion size, retinitis preceded antiretroviral treatment in each patient. Conclusions Patients presenting to a tertiary medical center in northern Thailand have advanced CMV retinitis, possibly due to delayed diagnosis. Earlier screening and treatment of CMV retinitis may limit progression of disease and prevent visual impairment in this population. PMID:22265148
Petritz, Olivia A; Guzman, David Sanchez-Migallon; Gustavsen, Kate; Wiggans, K Tomo; Kass, Philip H; Houck, Emma; Murphy, Christopher J; Paul-Murphy, Joanne
2016-01-01
OBJECTIVE :To determine the mydriatic effects of topical rocuronium bromide administration in Hispaniolan Amazon parrots (Amazona ventralis) and to identify any adverse effects associated with treatment. Randomized crossover study. 8 healthy adult Hispaniolan Amazon parrots. Rocuronium bromide (20 μL/eye; 10 mg/mL) or saline (20 μL/eye; 0.9% NaCl) solution was administered in both eyes of each bird with a 26-day washout period. The birds were manually restrained in lateral recumbency with the apex of the cornea positioned upward for 2 minutes following administration in each eye. Infrared pupillometry and direct pupillary light reflex measurements were used to evaluate the mydriatic effects. Pupillary measurements were recorded prior to administration and every 20 minutes for 2 hours after administration, then hourly for a total of 7 hours. A brief physical examination was performed, direct pupillary light reflex was tested, and fluorescein staining was performed on each eye of each bird 24 hours after administration. A significant difference in pupillary diameter for the active versus control treatment group was noted from 20 to 360 minutes after drug administration, but not at 420 minutes. Minimal adverse effects were noted. Three birds had transient inferior eyelid paresis noted in both eyes after receiving rocuronium; 24 hours after the treatment, no differences in ocular measurements existed between the active and control treatments. Results suggested that topical rocuronium bromide administration may be safely used for pupillary dilation in Hispaniolan Amazon parrots and could be used for clinical evaluation, fundus imaging, and surgical interventions involving the lens and posterior segment in this species.
Croft, Mary Ann; Mcdonald, Jared P.; James, Rebecca J.; Heatley, Gregg A.; Lin, Ting-Li; Lütjen-Drecoll, Elke; Kaufman, Paul L.
2009-01-01
Purpose To determine how surgically altering the normal relationship between the lens and the ciliary body in rhesus monkeys affects centripetal ciliary body and lens movement. Methods In 18 rhesus monkey eyes (aged 6–27 years), accommodation was induced before and after surgery by electrical stimulation of the Edinger-Westphal (E–W) nucleus. Accommodative amplitude was measured by coincidence refractometry. Goniovideography was performed before and after intra- and extra-capsular lens extraction (ICLE, ECLE) and anterior regional zonulolysis. Centripetal lens/capsule movements, centripetal ciliary process (CP) movements, and circumlental space were measured by computerized image analysis of the goniovideography images. Results Centripetal accommodative CP and capsule movement increased in velocity and amplitude post-ECLE compared to pre-ECLE regardless of age (n=5). The presence of the lens substance retarded capsule movement by ~21% in the young eyes and by ~62% in the older eyes. Post-ICLE compared to pre-ICLE centripetal accommodative CP movement was dampened in all eyes in which the anterior vitreous was disturbed (n=7), but not in eyes in which the anterior vitreous was left intact (n=2). Following anterior regional zonulolysis (n=4), lens position shifted toward the lysed quadrant during accommodation. Conclusions The presence of the lens substance, capsule zonular attachments, and Wiegers ligament may play a role in centripetal CP movement. The capsule is still capable of centripetal movement in the older eye (although at a reduced capacity) and may have the ability to produce ~6 diopters of accommodation in the presence of a normal young crystalline lens or a similar surrogate. PMID:18552393
Eyes-Closed Single-Limb Balance is Not Related to Hypermobility Status in Dancers.
Marulli, Tiffany A; Harmon-Matthews, Lindsay E; Davis-Coen, J Hope; Willigenburg, Nienke W; Hewett, Timothy E
2017-06-15
Hypermobility may be associated with decreased lower extremity proprioception, which in turn may increase injury risk. The prevalence of hypermobility in dancers varies across studies, but joint hypermobility appears to be more common in dancers than in the general population. The purpose of this study was to determine how hypermobility affects eyes-closed single-limb balance as an indirect measure of proprioception in dancers. The secondary aim was to compare hypermobility and balance across dancer affiliation groups. Data were collected from 45 professional dancers, 11 collegiate modern dancers, 227 student dancers, and 15 pre-professional dancers during routine dance screens. Dancer hypermobility status was assessed via an eight-point Beighton-Horan Laxity test. Single-limb balance time, in seconds, was assessed in parallel position with the eyes closed. Hypermobile (HM) and non-hypermobile (NHM) dancers showed very similar balance times (HM median: 36.5 seconds; NHM median: 33.0 seconds; p = 0.982). Hypermobility was not significantly different between dancer affiliation groups (p = 0.154): 47% in ballet academy students, 27% in collegiate modern dancers, 62% in pre-professional dancers, and 36% in professional dancers. The student, pre-professional, and professional ballet dancers all demonstrated longer balance times than the collegiate modern dancers; however, this difference was only significant between the professional ballet dancers and collegiate modern dancers (p = 0.026). Dancers demonstrated a higher prevalence of hypermobility than what has been reported for the general population. Joint hypermobility did not affect eyes-closed single-limb balance time. Future studies are needed to determine if joint hypermobility affects more sensitive measures of proprioception and risk of injury.
Escobar, André; da Rocha, Rozana Wendler; Midon, Monica; de Almeida, Ricardo Miyasaka; Filho, Darcio Zangirolami; Werther, Karin
2017-06-01
The aim of this study was to determine the minimum anesthetic concentration (MAC) of isoflurane, and to investigate if tramadol changes the isoflurane MAC in white-eyed parakeets (Psittacara leucophthalmus). Ten adult birds weighing 157 ± 9 g were anesthetized with isoflurane in oxygen under mechanical ventilation. Isoflurane concentration for the first bird was adjusted to 2.2%, and after 15 min an electrical stimulus was applied in the thigh area to observe the response (movement or nonmovement). Isoflurane concentration for the subsequent bird was increased by 10% if the previous bird moved, or decreased by 10% if the previous bird did not move. This procedure was performed serially until at least four sequential crossover events were detected. A crossover event was defined as a sequence of two birds with different responses (positive or negative) to the electrical stimulus. Isoflurane MAC was calculated as the mean isoflurane concentration value at the crossover events. After 1 wk, the same birds were reanesthetized with isoflurane and MAC was determined at 15 and 30 min after intramuscular administration of 10 mg/kg of tramadol using the same method. A paired t-test (P < 0.05%) was used to detect significant differences for MAC between treatments. Isoflurane MAC in this population of white-eyed parakeets was 2.47 ± 0.09%. Isoflurane MAC values 15 and 30 min after tramadol administration were indistinguishable from each other (pooled value was 2.50 ± 0.18%); they were also indistinguishable from isoflurane MAC without tramadol. The isoflurane MAC value in white-eyed parakeets is higher than reported for other bird species. Tramadol (10 mg/kg, i.m.) does not change isoflurane MAC in these birds.
ERIC Educational Resources Information Center
Asfar, Taghrid; Lee, David J.; Lam, Byron L.; Murchison, Ann P.; Mayro, Eileen L.; Owsley, Cynthia; McGwin, Gerald; Gower, Emily W.; Friedman, David S.; Saaddine, Jinan
2018-01-01
Background: Smoking causes blindness-related diseases. Eye-care providers are uniquely positioned to help their patients quit smoking. Aims: Using a pre-/postevaluation design, this study evaluated a web-based training in smoking cessation counseling targeting eye-care providers. Method: The training was developed based on the 3A1R protocol:…
Singh, Narinder Pal; Walker, Robbie James Eades; Cowan, Fiona; Davidson, Arthur Craig; Roberts, David Newton
2014-05-01
Continuous positive airway pressure (CPAP) is the gold standard treatment for moderate to severe obstructive sleep apnoea (OSA). Eye-related side effects of CPAP are commonly attributed to a poorly sealed mask, allowing leaked air to blow over the eye. We present 3 cases where attended polysomnography (A-PSG) demonstrated CPAP-associated retrograde air escape via the nasolacrimal system (CRANS) in the absence of any mask leaks. Symptoms included dry eye, epiphora, air escape from the medial canthus, and eyelid flutter. Symptoms were controlled with a variety of surgical and nonsurgical techniques. CRANS represents a previously undescribed clinical entity. CRANS may be responsible for some CPAP-related eye side effects and possibly for rarer secondary eye complications, including conjunctivitis and corneal ulceration. CRANS should be suspected in any patient on CPAP complaining of eye symptoms. CRANS may be diagnosed through careful observation during A-PSG and confirmed by performing a "saline bubble test." Management options include nonsurgical (mask alternatives, humidification, nasopharyngeal airway) and surgical techniques (nasal airway surgery, inferior turbinate out-fracture and adhesion, injection of bulking agent around Hasner's valve).
Axis of Eye Rotation Changes with Head-Pitch Orientation during Head Impulses about Earth-Vertical
Schubert, Michael C.; Clendaniel, Richard A.; Carey, John P.; Della Santina, Charles C.; Minor, Lloyd B.; Zee, David S.
2006-01-01
The goal of this study was to assess how the axis of head rotation, Listing's law, and eye position influence the axis of eye rotation during brief, rapid head rotations. We specifically asked how the axis of eye rotation during the initial angular vestibuloocular reflex (VOR) changed when the pitch orientation of the head relative to Earth-vertical was varied, but the initial position of the eye in the orbit and the orientation of Listing's plane with respect to the head were fixed. We measured three-dimensional eye and head rotation axes in eight normal humans using the search coil technique during head-and-trunk (whole-body) and head-on-trunk (head-only) “impulses” about an Earth-vertical axis. The head was initially oriented at one of five pitch angles (30° nose down, 15° nose down, 0°, 15° nose up, 30° nose up). The fixation target was always aligned with the nasooccipital axis. Whole-body impulses were passive, unpredictable, manual, rotations with peak-amplitude of ∼20°, peak-velocity of ∼80°/s, and peak-acceleration of ∼1000°/s2. Head-only impulses were also passive, unpredictable, manual, rotations with peak-amplitude of ∼20°, peak-velocity of ∼150°/s, and peak-acceleration of ∼3000°/s2. During whole-body impulses, the axis of eye rotation tilted in the same direction, and by an amount proportional (0.51 ± 0.09), to the starting pitch head orientation (P < 0.05). This proportionality constant decreased slightly to 0.39 ± 0.08 (P < 0.05) during head-only impulses. Using the head-only impulse data, with the head pitched up, we showed that only 50% of the tilt in the axis of eye rotation could be predicted from vectorial summation of the gains (eye velocity/head velocity) obtained for rotations about the pure yaw and roll head axes. Thus, even when the orientation of Listing's plane and eye position in the orbit are fixed, the axis of eye rotation during the VOR reflects a compromise between the requirements of Listing's law and a perfectly compensatory VOR. PMID:16552499
Speiser, Daniel I; Gagnon, Yakir Luc; Chhetri, Raghav K; Oldenburg, Amy L; Johnsen, Sönke
2016-11-01
The eyes of scallops form images using a concave spherical mirror and contain two separate retinas, one layered on top of the other. Behavioral and electrophysiological studies indicate that the images formed by these eyes have angular resolutions of about 2°. Based on previous ray-tracing models, it has been thought that the more distal of the two retinas lies near the focal point of the mirror and that the proximal retina, positioned closer to the mirror at the back of the eye, receives light that is out-of-focus. Here, we propose three mechanisms through which both retinas may receive focused light: (1) chromatic aberration produced by the lens may cause the focal points for longer and shorter wavelengths to fall near the distal and proximal retinas, respectively; (2) focused light from near and far objects may fall on the distal and proximal retinas, respectively; and (3) the eyes of scallops may be dynamic structures that change shape to determine which retina receives focused light. To test our hypotheses, we used optical coherence tomography (OCT), a method of near-infrared optical depth-ranging, to acquire virtual cross-sections of live, intact eyes from the bay scallop Argopecten irradians Next, we used a custom-built ray-tracing model to estimate the qualities of the images that fall on an eye's distal and proximal retinas as functions of the wavelengths of light entering the eye (400-700 nm), object distances (0.01-1 m), and the overall shape of the eye. When we assume 550 nm wavelength light and object distances greater than 0.01 m, our model predicts that the angular resolutions of the distal and proximal retinas are 2° and 7°, respectively. Our model also predicts that neither chromatic aberration nor differences in object distance lead to focused light falling on the distal and proximal retinas simultaneously. However, if scallops can manipulate the shapes of their eyes, perhaps through muscle contractions, we speculate that they may be able to influence the qualities of the images that fall on their proximal retinas and-to a lesser extent-those that fall on their distal retinas as well. © The Author 2016. Published by Oxford University Press on behalf of the Society for Integrative and Comparative Biology.
ERIC Educational Resources Information Center
Nesbit, Larry L.
A research study was designed to test the relationship between the number of eye fixations and amount of learning as determined by a criterion referenced posttest. The study sought to answer the following questions: (1) Are differences in eye movement indices related to the posttest score? (2) Do differences in eye movement indices of subjects…
Pelcová, Pavlína; Vičarová, Petra; Ridošková, Andrea; Dočekalová, Hana; Kopp, Radovan; Mareš, Jan; Poštulková, Eva
2017-11-01
The mercury bioaccumulation by common carp (Cyprinus carpio L.) tissues (gills, skin, eyes, scales, muscle, brain, kidneys, liver, and spleen) and the capability of the diffusive gradient in thin film (DGT) technique to predict bioavailability of mercury for individual carp's tissues were evaluated. Carp and DGT units were exposed to increasing concentrations of mercury (Hg 2+ : 0 μg L -1 , 0.5 μg L -1 , 1.5 μg L -1 and 3.0 μg L -1 ) in fish tanks for 14 days. In the uncontaminated fish group, the highest mercury concentration was determined in the muscle tissues and, in fish groups exposed to mercury, the highest mercury concentration was determined in the detoxification (kidneys) and input (gills) organs. A strong and positive correlation between the rate of mercury uptake by the DGT technique and the rate of mercury accumulation by fish tissues (gills, skin, scales, and eyes) was observed. Copyright © 2017 Elsevier Ltd. All rights reserved.
[Ultrasonographic findings in ocular toxocariasis].
Morais, Fábio Barreto; Maciel, Ana Lúcia; Arantes, Tiago Eugênio Farias e; Muccioli, Cristina; Allemann, Norma
2012-01-01
To evaluate ophthalmic ultrasound findings in the three presentation forms of ocular toxocariasis (peripheral or posterior pole granulomas and chronic endophthalmitis), in patients with confirmed diagnosis of ocular toxocariasis. 11 patients (11 eyes) with clinical and confirmed diagnosis of active ocular toxocariasis, presented positive ELISA test, were analyzed, prospectively, in the study. The patients were submitted to an ocular ultrasound examination (10-MHz transducer, contact technique). In the series of 11 patients, mean age was 7.9 years-old (range from 2 to 17 y), 73% male, referring previous contact with dogs (91%), and with the soil (50%), no referral of appetite perversion. In the analyses of compromised eyes (11 eyes), the ophthalmoscopic examination revealed the following distribution of the 3 forms of ocular toxocariasis: 7 cases (63.6%), posterior pole granuloma; 1 (9.1%), chronic endophthalmitis; 2 (18.2%), peripheral granuloma; and 1 (9.1%), posterior pole granuloma associated with chronic endophthalmitis. Visual acuity impairment: no light perception (3 eyes, 27.3%); hand motion (4 eyes, 36.4%); counting fingers at 10 cm (1 eye, 9.1%); 20/200 (1 eye, 9.1%); 20/70 (1 eye, 9.1%); undefined (1 eye, 9.1%). Serology was positive to Toxocara canis (ELISA test) in 100% of the cases. Ophthalmoscopy was difficult or impossible in 64% of the cases due to the media opacity. Ultrasound findings noted were vitreous membranes with retinal attachment (100%); parietal lesions (granulomas) with high (80%) or medium (20%) reflectivity. The most consistent ultrasound finding in the eye with toxocariasis was a high-reflectivity retinal mass, located in posterior pole or periphery, which may be calcified, and which has as main characteristic the adherence of vitreous membranes. In addition to clinical history, systemic evaluation and serology, the ultrasound can help in the diagnosis of ocular toxocariasis, especially in media opacities.
Eason, Jessica; Williams, Antionette L; Chawla, Bahaar; Apsey, Christian; Bohnsack, Brenda L
2017-09-01
Ethanol (ETOH) exposure during pregnancy is associated with craniofacial and neurologic abnormalities, but infrequently disrupts the anterior segment of the eye. In these studies, we used zebrafish to investigate differences in the teratogenic effect of ETOH on craniofacial, periocular, and ocular neural crest. Zebrafish eye and neural crest development was analyzed by means of live imaging, TUNEL (terminal deoxynucleotidyl transferase dUTP nick end labeling) assay, immunostaining, detection of reactive oxygen species, and in situ hybridization. Our studies demonstrated that foxd3-positive neural crest cells in the periocular mesenchyme and developing eye were less sensitive to ETOH than sox10-positive craniofacial neural crest cells that form the pharyngeal arches and jaw. ETOH increased apoptosis in the retina, but did not affect survival of periocular and ocular neural crest cells. ETOH also did not increase reactive oxygen species within the eye. In contrast, ETOH increased ventral neural crest apoptosis and reactive oxygen species production in the facial mesenchyme. In the eye and craniofacial region, sod2 showed high levels of expression in the anterior segment and in the setting of Sod2 knockdown, low levels of ETOH decreased migration of foxd3-positive neural crest cells into the developing eye. However, ETOH had minimal effect on the periocular and ocular expression of transcription factors (pitx2 and foxc1) that regulate anterior segment development. Neural crest cells contributing to the anterior segment of the eye exhibit increased ability to withstand ETOH-induced oxidative stress and apoptosis. These studies explain the rarity of anterior segment dysgenesis despite the frequent craniofacial abnormalities in fetal alcohol syndrome. Birth Defects Research 109:1212-1227, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Mapping and correcting the influence of gaze position on pupil size measurements
Petrov, Alexander A.
2015-01-01
Pupil size is correlated with a wide variety of important cognitive variables and is increasingly being used by cognitive scientists. Pupil data can be recorded inexpensively and non-invasively by many commonly used video-based eye-tracking cameras. Despite the relative ease of data collection and increasing prevalence of pupil data in the cognitive literature, researchers often underestimate the methodological challenges associated with controlling for confounds that can result in misinterpretation of their data. One serious confound that is often not properly controlled is pupil foreshortening error (PFE)—the foreshortening of the pupil image as the eye rotates away from the camera. Here we systematically map PFE using an artificial eye model and then apply a geometric model correction. Three artificial eyes with different fixed pupil sizes were used to systematically measure changes in pupil size as a function of gaze position with a desktop EyeLink 1000 tracker. A grid-based map of pupil measurements was recorded with each artificial eye across three experimental layouts of the eye-tracking camera and display. Large, systematic deviations in pupil size were observed across all nine maps. The measured PFE was corrected by a geometric model that expressed the foreshortening of the pupil area as a function of the cosine of the angle between the eye-to-camera axis and the eye-to-stimulus axis. The model reduced the root mean squared error of pupil measurements by 82.5 % when the model parameters were pre-set to the physical layout dimensions, and by 97.5 % when they were optimized to fit the empirical error surface. PMID:25953668
Choi, Ki Hwan; Chung, Song Ee; Chung, Tae Young; Chung, Eui Sang
2007-04-01
To assess the efficacy of the ultrasound biomicroscopic (UBM) method in estimating the sulcus-to-sulcus horizontal diameter for Visian Implantable Contact Lens (ICL, model V4) length determination to obtain optimal ICL vault. The results of postoperative ICL vaults in 30 eyes of 18 patients were retrospectively analyzed. In 17 eyes, ICL length was determined using the conventional method, and in 13 eyes, ICL length was determined using the UBM method. The UBM method was carried out by measuring the sulcus to limbus distance on each side by 50 MHz UBM and adding the white-to-white diameter by caliper or Orbscan. The ICL vaults were measured using the UBM method at 1 and 6 months postoperatively and the results were compared between the two groups. Ideal ICL vault was defined as vault between 250 and 750 microm. The relation between the ICL vault, footplate location, and ICL power was also investigated. In the UBM method group, ICL vault was within the ideal range in all 13 (100%) eyes at 1 and 6 months postoperatively, whereas in the conventional method group, 10 (58.8%) eyes showed ideal vault at 1 month postoperatively (P = .01) and 9 (52.9%) eyes showed ideal vault at 6 months postoperatively (P < .01). The ideal ICL footplate location was achieved in the ciliary sulcus in 11 (84.6%) eyes of the UBM method group and 10 (64.7%) eyes of the conventional method group. However, the differences between the two groups were not statistically significant. The ICL vault was not significantly affected by the ICL power. Implantable Contact Lens length determined by the UBM method achieved significantly more ideal ICL vault than that of the conventional white-to-white method. The UBM method is superior to the conventional method in terms of predicting the sulcus-to-sulcus horizontal diameter for ICL length determination.
Fetal Eye Movements on Magnetic Resonance Imaging
Woitek, Ramona; Kasprian, Gregor; Lindner, Christian; Stuhr, Fritz; Weber, Michael; Schöpf, Veronika; Brugger, Peter C.; Asenbaum, Ulrika; Furtner, Julia; Bettelheim, Dieter; Seidl, Rainer; Prayer, Daniela
2013-01-01
Objectives Eye movements are the physical expression of upper fetal brainstem function. Our aim was to identify and differentiate specific types of fetal eye movement patterns using dynamic MRI sequences. Their occurrence as well as the presence of conjugated eyeball motion and consistently parallel eyeball position was systematically analyzed. Methods Dynamic SSFP sequences were acquired in 72 singleton fetuses (17–40 GW, three age groups [17–23 GW, 24–32 GW, 33–40 GW]). Fetal eye movements were evaluated according to a modified classification originally published by Birnholz (1981): Type 0: no eye movements; Type I: single transient deviations; Type Ia: fast deviation, slower reposition; Type Ib: fast deviation, fast reposition; Type II: single prolonged eye movements; Type III: complex sequences; and Type IV: nystagmoid. Results In 95.8% of fetuses, the evaluation of eye movements was possible using MRI, with a mean acquisition time of 70 seconds. Due to head motion, 4.2% of the fetuses and 20.1% of all dynamic SSFP sequences were excluded. Eye movements were observed in 45 fetuses (65.2%). Significant differences between the age groups were found for Type I (p = 0.03), Type Ia (p = 0.031), and Type IV eye movements (p = 0.033). Consistently parallel bulbs were found in 27.3–45%. Conclusions In human fetuses, different eye movement patterns can be identified and described by MRI in utero. In addition to the originally classified eye movement patterns, a novel subtype has been observed, which apparently characterizes an important step in fetal brainstem development. We evaluated, for the first time, eyeball position in fetuses. Ultimately, the assessment of fetal eye movements by MRI yields the potential to identify early signs of brainstem dysfunction, as encountered in brain malformations such as Chiari II or molar tooth malformations. PMID:24194885
Code of Federal Regulations, 2011 CFR
2011-01-01
... Definitions. (a) A patient is any person who has had an eye examination. (b) An eye examination is the process of determining the refractive condition of a person's eyes or the presence of any visual anomaly by... ophthalmic goods subsequent to an eye examination. (e) An ophthalmologist is any Doctor of Medicine or...
Code of Federal Regulations, 2010 CFR
2010-01-01
... Definitions. (a) A patient is any person who has had an eye examination. (b) An eye examination is the process of determining the refractive condition of a person's eyes or the presence of any visual anomaly by... ophthalmic goods subsequent to an eye examination. (e) An ophthalmologist is any Doctor of Medicine or...
Fukuda, Masamichi; Inoue, Amane; Sasaki, Kazuyuki; Takahashi, Nobuo
2004-01-01
Pharmacokinetic studies of antibacterial agents for infectious eye diseases have usually been performed on normal rabbit eyes. In this study, the intraocular penetration of fluoroquinolone ophthalmic solutions was determined in normal rabbit eyes and in rabbit eyes that had the corneal epithelium intentionally removed. We determined the intraocular penetration of ofloxacin (OFLX), levofloxacin (LVFX), and norfloxacin (NFLX), fluoroquinolone ophthalmic solutions that are already on the market and undergoing clinical studies, by injecting 50 microl of each solution into the cul-de-sacs of rabbit eyes three times at 15-min intervals. The drug concentration at 10, 30, 60, 120, and 240 min after final instillation was determined by high-performance liquid chromatography. The maximum concentration in the aqueous humor of normal rabbit eyes was 2.09 +/- 1.56 microg/ml (60 min, OFLX), 2.57 +/- 1.00 microg/ml (30 min, LVFX), and 0.42 +/- 0.12 microg/ml (120 min, NFLX). The drug concentration in the aqueous humor of eyes with intentionally removed corneal epithelium was 12.50 +/- 5.62 microg/ml (30 min, OFLX), 9.02 +/- 2.45 microg/ml (60 min, LVFX), and 8.54 +/- 5.17 microg/ml (30 min, NFLX). The drug penetration of the eye drops into eyes with removed corneal epithelium was around 6 times (OFLX), 3.5 times (LVFX), and 20 times (NFLX) higher than the penetration into the eye with normal cornea. Among the pharmacokinetic parameters of the three ophthalmic solutions according to the one-compartment model, the maximum concentration in the aqueous and the area under the concentration-time curve in the aqueous tended to be higher in the eyes with intentionally removed corneal epithelia than in those with normal corneas.
The Effect of TNF-α Blocker HL036337 and Its Best Concentration to Inhibit Dry Eye Inflammation.
Choi, Wungrak; Noh, Hyemi; Yeo, Areum; Jang, Hanmil; Ahn, Hyea Kyung; Song, Yeon Jung; Lee, Hyung Keun
2016-08-01
Dry eye syndrome is commonly thought of as an inflammatory disease, and we have previously presented data showing the effectiveness of topical TNF-α blocker agents for the treatment of this condition. The purpose of this study was to investigate the effectiveness of the TNF-α blocking agent HL036337 compared to cyclosporine A for the treatment of dry eye induced inflammation in order to establish whether HL036337 represents a more effective method for suppressing inflammation. The efficacy of HL036337 and cyclosporine A was determined using an experimental murine dry eye model. The TNF-α blocker HL036337 is a modified form of TNF receptor I. Using dry eye induced C57BL/6 mice (n = 45), corneal erosion was measured at day 4 and 7 after topical treatment with cyclosporine A or HL036337. To determine the effective treatment dose, 0.25, 0.5, 1, 2.5, and 5 mg/mL of HL036337 were topically administered twice per day to dry eye induced murine corneas for 1 week. The optimal concentration of the TNF-α blocker HL036337 for treatment of dry eye induced corneal erosion was determined to be 1 mg/mL. Dry eye induced corneal erosion was improved after 1 week with topically applied cyclosporine A and HL036337 at 1 mg/mL. HL036337 administered topically at 1 mg/mL effectively improved corneal erosion induced by dry eye. This finding may also suggest that inhibition of TNF-α can improve dry eye syndrome.
Tufail, Adnan; Kapetanakis, Venediktos V; Salas-Vega, Sebastian; Egan, Catherine; Rudisill, Caroline; Owen, Christopher G; Lee, Aaron; Louw, Vern; Anderson, John; Liew, Gerald; Bolter, Louis; Bailey, Clare; Sadda, SriniVas; Taylor, Paul; Rudnicka, Alicja R
2016-12-01
Diabetic retinopathy screening in England involves labour-intensive manual grading of retinal images. Automated retinal image analysis systems (ARIASs) may offer an alternative to manual grading. To determine the screening performance and cost-effectiveness of ARIASs to replace level 1 human graders or pre-screen with ARIASs in the NHS diabetic eye screening programme (DESP). To examine technical issues associated with implementation. Observational retrospective measurement comparison study with a real-time evaluation of technical issues and a decision-analytic model to evaluate cost-effectiveness. A NHS DESP. Consecutive diabetic patients who attended a routine annual NHS DESP visit. Retinal images were manually graded and processed by three ARIASs: iGradingM (version 1.1; originally Medalytix Group Ltd, Manchester, UK, but purchased by Digital Healthcare, Cambridge, UK, at the initiation of the study, purchased in turn by EMIS Health, Leeds, UK, after conclusion of the study), Retmarker (version 0.8.2, Retmarker Ltd, Coimbra, Portugal) and EyeArt (Eyenuk Inc., Woodland Hills, CA, USA). The final manual grade was used as the reference standard. Arbitration on a subset of discrepancies between manual grading and the use of an ARIAS by a reading centre masked to all grading was used to create a reference standard manual grade modified by arbitration. Screening performance (sensitivity, specificity, false-positive rate and likelihood ratios) and diagnostic accuracy [95% confidence intervals (CIs)] of ARIASs. A secondary analysis explored the influence of camera type and patients' ethnicity, age and sex on screening performance. Economic analysis estimated the cost per appropriate screening outcome identified. A total of 20,258 patients with 102,856 images were entered into the study. The sensitivity point estimates of the ARIASs were as follows: EyeArt 94.7% (95% CI 94.2% to 95.2%) for any retinopathy, 93.8% (95% CI 92.9% to 94.6%) for referable retinopathy and 99.6% (95% CI 97.0% to 99.9%) for proliferative retinopathy; and Retmarker 73.0% (95% CI 72.0% to 74.0%) for any retinopathy, 85.0% (95% CI 83.6% to 86.2%) for referable retinopathy and 97.9% (95% CI 94.9 to 99.1%) for proliferative retinopathy. iGradingM classified all images as either 'disease' or 'ungradable', limiting further iGradingM analysis. The sensitivity and false-positive rates for EyeArt were not affected by ethnicity, sex or camera type but sensitivity declined marginally with increasing patient age. The screening performance of Retmarker appeared to vary with patient's age, ethnicity and camera type. Both EyeArt and Retmarker were cost saving relative to manual grading either as a replacement for level 1 human grading or used prior to level 1 human grading, although the latter was less cost-effective. A threshold analysis testing the highest ARIAS cost per patient before which ARIASs became more expensive per appropriate outcome than human grading, when used to replace level 1 grader, was Retmarker £3.82 and EyeArt £2.71 per patient. The non-randomised study design limited the health economic analysis but the same retinal images were processed by all ARIASs in this measurement comparison study. Retmarker and EyeArt achieved acceptable sensitivity for referable retinopathy and false-positive rates (compared with human graders as reference standard) and appear to be cost-effective alternatives to a purely manual grading approach. Future work is required to develop technical specifications to optimise deployment and address potential governance issues. The National Institute for Health Research (NIHR) Health Technology Assessment programme, a Fight for Sight Grant (Hirsch grant award) and the Department of Health's NIHR Biomedical Research Centre for Ophthalmology at Moorfields Eye Hospital and the University College London Institute of Ophthalmology.
2004-06-01
in first third of the night. REM sleep is associated with an extremely active brain that is frequently dreaming with bursts of rapid eye movement...these areas. 3. Human Sleep and Fatigue Sleep is nature’s process of resting the body although brain activity continues throughout the rest...midday roughly between 1500 and 1700 (LeClair, 2001). Disruption of one’s circadian rhythm to accommodate adjustments in unconventional working hours
Safety of laser use under the dental microscope.
Saegusa, Hidetoshi; Watanabe, Satoshi; Anjo, Tomoo; Ebihara, Arata; Suda, Hideaki
2010-04-01
The aim of this study was to investigate the safety of laser use under the dental microscope. Nd:YAG, Er:YAG and diode lasers were used. The end of the tips was positioned at a distance of 5 cm from the objective lens of a dental microscope. Each eye protector was made into a flat disc, which was fixed on the lens of the microscope. The filters were placed in front of the objective lens or behind the eye lens. Transmitted energy through the microscope with or without the filters was measured. No transmitted laser energy was detected when using matched eye protectors. Mismatched eye protectors were not effective for shutting out laser energy, especially for Nd:YAG and diode lasers. None or very little laser energy was detected through the microscope even without any laser filter. Matched filters shut out all laser energy irrespective of their positions.
Penha, Alexandra Marcha; Burkhardt, Eva; Schaeffel, Frank
2012-01-01
Purpose Intravitreal insulin has been shown to be a powerful stimulator of myopia in chickens, in particular if the retinal image is degraded or defocused. In most tissues, the insulin receptor activates two main signaling pathways: a) the mitogen-activated protein kinase (MAPK) cascade (e.g., mitogen-activated protein kinasem kinase [MEK] and extracellular regulated kinase [ERK]) and b) the phosphatidylinositol 3-kinase (PI3K)/protein kinase B (Akt) pathway. In the current study, insulin was injected, and these pathways were separately inhibited to determine which is activated when the retinal image is defocused by spectacle lenses. Methods Chicks were treated with either +7 D, −7 D, or no lenses. They were intravitreally injected with insulin, the MEK inhibitor U0126, the PI3K inhibitor Ly294002, or a combination of insulin and one of the inhibitors. Refractions and ocular dimension were measured at the beginning and after four days of treatment. The retinal proteins of the chicks were measured with western blots after 2 h and four days of treatment. Incubation occurred with anti-Akt1, anti-Erk1/2, anti-phospho-AktThr308, and anti-phospho-Erk1/2(Thr202/Tyr204) antibodies, and the ratio between the relative intensity of the phospho-form and the total-form was calculated. Results Chicks wearing positive lenses and injected with saline and with PI3K inhibitor compensated for the imposed defocus and became hyperopic. Insulin injections and insulin plus PI3K inhibitor injections prevented lens-induced hyperopia, whereas the MEK inhibitor alone and insulin plus MEK inhibitor had no effect. Obviously, the MEK inhibitor suppressed the effect of insulin on eye growth in the plus lens–treated animals. Chicks treated with negative lenses and injected with insulin, or with insulin plus MEK inhibitor, overcompensated for the imposed defocus. This effect of insulin was not detected in eyes injected with PI3K inhibitor plus insulin, suggesting that the PI3K inhibitor suppressed the effects of insulin in minus lens–treated animals. Insulin increased the ratio of phospho-Akt/total-Akt in animals with normal visual exposure but even more so in chicks wearing plus or minus lenses. The increase was blocked by simultaneous PI3K inhibitor injections in control eyes but not in lens-treated eyes. Insulin also increased the ratio of phospho-ERK/total-ERK in animals with normal visual exposure and in animals wearing positive lenses, compared to U0126- and Ly294002-injected eyes. In contrast, no significant activation of the MEK/ERK pathway was observed in the negative lens–treated animals. Conclusions Intravitreal insulin promoted axial eye growth and stimulated both signaling pathways. The PI3K/Akt pathway was activated in control and plus and minus lens–treated eyes, but the MEK/ERK pathway was activated only with positive lenses or no lenses. With negative lenses, insulin did not stimulate the MEK/ERK signaling cascade. Independent of the pathway stimulated after insulin binding, the effect on insulin was always the same: an increase in eye growth. PMID:23112573
Penha, Alexandra Marcha; Burkhardt, Eva; Schaeffel, Frank; Feldkaemper, Marita P
2012-01-01
Intravitreal insulin has been shown to be a powerful stimulator of myopia in chickens, in particular if the retinal image is degraded or defocused. In most tissues, the insulin receptor activates two main signaling pathways: a) the mitogen-activated protein kinase (MAPK) cascade (e.g., mitogen-activated protein kinasem kinase [MEK] and extracellular regulated kinase [ERK]) and b) the phosphatidylinositol 3-kinase (PI3K)/protein kinase B (Akt) pathway. In the current study, insulin was injected, and these pathways were separately inhibited to determine which is activated when the retinal image is defocused by spectacle lenses. Chicks were treated with either +7 D, -7 D, or no lenses. They were intravitreally injected with insulin, the MEK inhibitor U0126, the PI3K inhibitor Ly294002, or a combination of insulin and one of the inhibitors. Refractions and ocular dimension were measured at the beginning and after four days of treatment. The retinal proteins of the chicks were measured with western blots after 2 h and four days of treatment. Incubation occurred with anti-Akt1, anti-Erk1/2, anti-phospho-Akt(Thr308), and anti-phospho-Erk1/2((Thr202/Tyr204)) antibodies, and the ratio between the relative intensity of the phospho-form and the total-form was calculated. Chicks wearing positive lenses and injected with saline and with PI3K inhibitor compensated for the imposed defocus and became hyperopic. Insulin injections and insulin plus PI3K inhibitor injections prevented lens-induced hyperopia, whereas the MEK inhibitor alone and insulin plus MEK inhibitor had no effect. Obviously, the MEK inhibitor suppressed the effect of insulin on eye growth in the plus lens-treated animals. Chicks treated with negative lenses and injected with insulin, or with insulin plus MEK inhibitor, overcompensated for the imposed defocus. This effect of insulin was not detected in eyes injected with PI3K inhibitor plus insulin, suggesting that the PI3K inhibitor suppressed the effects of insulin in minus lens-treated animals. Insulin increased the ratio of phospho-Akt/total-Akt in animals with normal visual exposure but even more so in chicks wearing plus or minus lenses. The increase was blocked by simultaneous PI3K inhibitor injections in control eyes but not in lens-treated eyes. Insulin also increased the ratio of phospho-ERK/total-ERK in animals with normal visual exposure and in animals wearing positive lenses, compared to U0126- and Ly294002-injected eyes. In contrast, no significant activation of the MEK/ERK pathway was observed in the negative lens-treated animals. Intravitreal insulin promoted axial eye growth and stimulated both signaling pathways. The PI3K/Akt pathway was activated in control and plus and minus lens-treated eyes, but the MEK/ERK pathway was activated only with positive lenses or no lenses. With negative lenses, insulin did not stimulate the MEK/ERK signaling cascade. Independent of the pathway stimulated after insulin binding, the effect on insulin was always the same: an increase in eye growth.
A Clinical Study of Subtype-based Prevalence of Dry Eye.
Rege, Aditya; Kulkarni, Varsha; Puthran, Neelam; Khandgave, Tejaswini
2013-10-01
Dry Eye is a multifactorial disease of the tearfilm and the ocular surface which may be due to reduced tear production or excessive tear evaporation resulting in discomfort, visual disturbance, and tear film instability with a potential damage to the ocular surface. Various population-based studies have been done to find out the prevalence and the magnitude of the problem. Women Health Study reported prevalence of 7.8% after screening 36995 subjects above 49 years by interview. The prevalence reported by Blue Mountain Study was 15.3% .The Beaver Dam Study and Shiphai Eye studies are other studies reporting prevalence of 14.5% and 33.7% respectively. McMonnies questionnaire is a widely used screening instrument for Dry-Eye syndromes with sensitivity reportedly varying between 87% and 98% and specificity between 87% and 97%. Prevalence studies use McMonnie's questionnaire for screening individuals for Dry Eye, whereafter tests like Schirmer's test, Tear Film Break Up Time test, Rose Bengal test, Lissamine Green test and Meibomian Gland Dysfunction test are useful for further evaluation. While these tests help to differentiate the subtypes of Dry Eye such as Lipid Anomaly Dry Eye, Aqueous Tear Deficiency and Mucin Layer Deficiency, however, their sensitivity and specificity has not been widely studied. Additionally, very few studies have reported the prevalence of the various subtypes of Dry Eye. To determine the subtype-based prevalence of Dry Eye, to study the specificity and sensitivity of clinical tests for Dry Eye and to correlate McMonnies questionnaire with Dry Eye tests results. A prospective, cross-sectional, observational study, duly approved by the Institutional Ethics Committee, was conducted from October 2010 to April 2012. A total of 4750 subjects above 18 yrs of age were screened by the McMonnies questionnaire. Respondents having a score greater than 14.5 were subjected to clinical Dry Eye tests. The data obtained was analyzed using chi-square test. p value < 0.005 was considered statistically significant.The specificity and sensitivity of each clinical test was calculated using Schirmer's test as gold standard. The prevalence of Dry Eye was 15.4%, with a female preponderance (p = 0.01) and a significant increase with age above 60 years was noted (p<0.0001). Tear Film Break Up Time was the most reliable test with a good sensitivity (68.85%) and specificity (78.32%). Lipid Anomaly Dry Eye was the most prevalent (14.48%) followed by Aqueous Tear Deficiency (13.36%) and Mucin Layer Deficiency (3.51%). A positive correlation between McMonnies score and severity of Dry Eye was seen. This study suggests that Lipid Layer Anomaly is the most prevalent subtype in Dry Eye. Tear Film Break Up Time test is the most likely test to diagnose mild Dry Eye. McMonies Questionnaire can be effectively used for screening of a large population. Tear Film Break Up Time was found to have better sensitivity as well as specificity than other tests used for diagnosing Dry Eye.
Structural Neural Substrates of Reading the Mind in the Eyes.
Sato, Wataru; Kochiyama, Takanori; Uono, Shota; Sawada, Reiko; Kubota, Yasutaka; Yoshimura, Sayaka; Toichi, Motomi
2016-01-01
The ability to read the minds of others in their eyes plays an important role in human adaptation to social environments. Behavioral studies have resulted in the development of a test to measure this ability (Reading the Mind in the Eyes Test, revised version; Eyes Test), and have demonstrated that this ability is consistent over time. Although functional neuroimaging studies revealed brain activation while performing the Eyes Test, the structural neural substrates supporting consistent performance on the Eyes Test remain unclear. In this study, we assessed the Eyes Test and analyzed structural magnetic resonance images using voxel-based morphometry (VBM) in healthy participants. Test performance was positively associated with the gray matter volumes of the dorsomedial prefrontal cortex, inferior parietal lobule (temporoparietal junction), and precuneus in the left hemisphere. These results suggest that the fronto-temporoparietal network structures support the consistent ability to read the mind in the eyes.
Intermediate view synthesis for eye-gazing
NASA Astrophysics Data System (ADS)
Baek, Eu-Ttuem; Ho, Yo-Sung
2015-01-01
Nonverbal communication, also known as body language, is an important form of communication. Nonverbal behaviors such as posture, eye contact, and gestures send strong messages. In regard to nonverbal communication, eye contact is one of the most important forms that an individual can use. However, lack of eye contact occurs when we use video conferencing system. The disparity between locations of the eyes and a camera gets in the way of eye contact. The lock of eye gazing can give unapproachable and unpleasant feeling. In this paper, we proposed an eye gazing correction for video conferencing. We use two cameras installed at the top and the bottom of the television. The captured two images are rendered with 2D warping at virtual position. We implement view morphing to the detected face, and synthesize the face and the warped image. Experimental results verify that the proposed system is effective in generating natural gaze-corrected images.
Interferon-gamma, macrophages, and virus spread after HSV-1 injection.
Cathcart, Heather M; Zheng, Mei; Covar, Jason J; Liu, Yi; Podolsky, Robert; Atherton, Sally S
2011-06-07
After uniocular anterior chamber (AC) injection of HSV-1, the anterior segment of BALB/c mice becomes inflamed and infected; however, virus does not spread from the anterior segment to cause retinitis in the injected eye. The purpose of these studies was to determine whether interferon (IFN-)-γ and Mac-1(+) cells play a role in preventing direct anterior-to-posterior spread of HSV-1 in the injected eye. One AC of adult female BALB/c mice was injected with HSV-1 (KOS). The location of IFN-α, IFN-β, and IFN-γ in the injected eye was determined by immunofluorescence, and mRNA expression was quantified by qPCR. Injected eyes of IFN-γ knockout or clodronate-treated macrophage-depleted mice were examined to determine whether the absence of IFN-γ or Mac-1(+) macrophages affected the sites or timing of virus spread. IFN-α, IFN-β, and IFN-γ were observed in the anterior segment of injected eyes through 72 hours and mRNA levels of IFN-β and IFN-γ were increased in virus-infected eyes 48 to 120 hours after infection. However, the absence of IFN-γ or macrophages did not affect either the sites or the timing of HSV-1 infection in injected eyes. Protection of the retina of the injected eye does not depend on a single cell type or cytokine. In addition, in the eye, as in other sites of the body, there are redundancies in the innate response to virus infection.
Combining user logging with eye tracking for interactive and dynamic applications.
Ooms, Kristien; Coltekin, Arzu; De Maeyer, Philippe; Dupont, Lien; Fabrikant, Sara; Incoul, Annelies; Kuhn, Matthias; Slabbinck, Hendrik; Vansteenkiste, Pieter; Van der Haegen, Lise
2015-12-01
User evaluations of interactive and dynamic applications face various challenges related to the active nature of these displays. For example, users can often zoom and pan on digital products, and these interactions cause changes in the extent and/or level of detail of the stimulus. Therefore, in eye tracking studies, when a user's gaze is at a particular screen position (gaze position) over a period of time, the information contained in this particular position may have changed. Such digital activities are commonplace in modern life, yet it has been difficult to automatically compare the changing information at the viewed position, especially across many participants. Existing solutions typically involve tedious and time-consuming manual work. In this article, we propose a methodology that can overcome this problem. By combining eye tracking with user logging (mouse and keyboard actions) with cartographic products, we are able to accurately reference screen coordinates to geographic coordinates. This referencing approach allows researchers to know which geographic object (location or attribute) corresponds to the gaze coordinates at all times. We tested the proposed approach through two case studies, and discuss the advantages and disadvantages of the applied methodology. Furthermore, the applicability of the proposed approach is discussed with respect to other fields of research that use eye tracking-namely, marketing, sports and movement sciences, and experimental psychology. From these case studies and discussions, we conclude that combining eye tracking and user-logging data is an essential step forward in efficiently studying user behavior with interactive and static stimuli in multiple research fields.
Ueda, Sayoko; Kumagai, Gaku; Otaki, Yusuke; Yamaguchi, Shinya; Kohshima, Shiro
2014-01-01
As facial color pattern around the eyes has been suggested to serve various adaptive functions related to the gaze signal, we compared the patterns among 25 canid species, focusing on the gaze signal, to estimate the function of facial color pattern in these species. The facial color patterns of the studied species could be categorized into the following three types based on contrast indices relating to the gaze signal: A-type (both pupil position in the eye outline and eye position in the face are clear), B-type (only the eye position is clear), and C-type (both the pupil and eye position are unclear). A-type faces with light-colored irises were observed in most studied species of the wolf-like clade and some of the red fox-like clade. A-type faces tended to be observed in species living in family groups all year-round, whereas B-type faces tended to be seen in solo/pair-living species. The duration of gazing behavior during which the facial gaze-signal is displayed to the other individual was longest in gray wolves with typical A-type faces, of intermediate length in fennec foxes with typical B-type faces, and shortest in bush dogs with typical C-type faces. These results suggest that the facial color pattern of canid species is related to their gaze communication and that canids with A-type faces, especially gray wolves, use the gaze signal in conspecific communication. PMID:24918751
Said, Azza Mohamed Ahmed; Zaki, Rania Gamal Eldin; Salah Eldin, Rania A; Nasr, Maha; Azab, Samar Saad; Elzankalony, Yaser Abdelmageuid
2017-04-04
Retinopathy of prematurity (ROP) is one of the targets for early detection and treatment to prevent childhood blindness in world health organization programs. The purpose of study was to evaluate the efficacy of intravitreal injection of 2-Methoxyestradiol (2-ME) nanoemulsion in regressing neovascularization of a ROP rat model. A prospective comparative case - control animal study conducted on 56 eyes of 28 healthy new born Sprague Dawley male albino rat. ROP was induced in 21 rats then two concentrations of 2-ME nanoparticles were injected in right eyes of 14 rats (low dose; study group I, high dose; study group II). A blank nanoemulsion was injected in the right eyes of seven rats (control positive group I). No injections performed in contralateral left eyes (control positive group II). Seven rats (14 eyes) were kept in room air (control negative group). On postnatal day 17, eyeballs were enucleated. Histological structure of the retina was examined using Hematoxylin and eosin staining. Vascular endothelial growth factor (VEGF) and glial fibrillary acidic protein (GFAP) expressions were detected by immunohistochemical studies. Intravitreal injection of 2-ME (in the two concentrations) caused marked regression of the new vascular tufts on the vitreal side with normal organization and thickness of the retina especially in study group II, which also show negative VEGF immunoreaction. Positive GFAP expression was detected in the control positive groups and study group (I). Intravitreal injection of 2-Methoxyestradiol nanoemulsion is a promising effective method in reduction of neovascularization of a ROP rat model.
Pediatric eye injuries due to nonpowder guns in the United States, 2002-2012.
Lee, Rachel; Fredrick, Douglas
2015-04-01
To identify epidemiologic trends in nonpowder gun-related pediatric eye injuries and to determine factors associated with severe injury requiring hospital admission. US emergency department data on pediatric eye injuries between 2002 and 2012 were reviewed using the National Electronic Injury Surveillance System. Literature review was conducted to determine trends in visual outcomes after treatment and use of eye protection. In 2012 roughly 3,161 children were treated in US emergency departments for nonpowder gun-related eye injuries. Since 2010 rates of severe nonpowder gun pediatric eye injury have increased by over 500% (P = 0.039). Specifically, while rates of hospital admission due to paintball gun eye injury have dropped precipitously (P = 0.0077), rates of admissions for air gun eye injuries have increased by over 600% since 2010 (P = 0.033). Children sustaining eye injury due to air guns are more likely to be diagnosed and admitted with foreign body or ocular puncture injury. Roughly 28% of documented cases of airsoft or BB gun-related injury had visual acuity worse than 20/50 after initial treatment. Over 98% of injuries occurred without eye protection. Air guns are rising in popularity and now account for the majority of pediatric eye injuries requiring hospital admissions. These eye injuries occur without ocular protection and may lead to permanent eye injury. Increasing regulations for eye protection, sales, and usage of air guns are needed to prevent serious pediatric eye injuries. Copyright © 2015 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Bellocchi, Stephanie; Muneaux, Mathilde; Bastien-Toniazzo, Mireille; Ducrot, Stephanie
2013-01-01
Most studies today agree about the link between visual-attention and oculomotor control during reading: attention seems to affect saccadic programming, that is, the position where the eyes land in a word. Moreover, recent studies show that visuo-attentional processes are strictly linked to normal and impaired reading. In particular, a large body…
Realization of the ergonomics design and automatic control of the fundus cameras
NASA Astrophysics Data System (ADS)
Zeng, Chi-liang; Xiao, Ze-xin; Deng, Shi-chao; Yu, Xin-ye
2012-12-01
The principles of ergonomics design in fundus cameras should be extending the agreeableness by automatic control. Firstly, a 3D positional numerical control system is designed for positioning the eye pupils of the patients who are doing fundus examinations. This system consists of a electronically controlled chin bracket for moving up and down, a lateral movement of binocular with the detector and the automatic refocusing of the edges of the eye pupils. Secondly, an auto-focusing device for the object plane of patient's fundus is designed, which collects the patient's fundus images automatically whether their eyes is ametropic or not. Finally, a moving visual target is developed for expanding the fields of the fundus images.
Adaptations and deficits in the vestibulo-ocular reflex after sixth nerve palsy.
Wong, Agnes M F; Tweed, Douglas; Sharpe, James A
2002-01-01
The effects of paralytic strabismus on the vestibulo-ocular reflex (VOR) have not been systematically investigated in humans. The purpose of this study was to analyze the VOR in patients with unilateral peripheral sixth nerve palsy. Twenty-one patients with unilateral peripheral sixth nerve palsy (6 severe, 7 moderate, 8 mild) and 15 normal subjects were studied. Subjects made sinusoidal +/-10 degrees head-on-body rotations in yaw and pitch at approximately 0.5 and 2 Hz, and in roll at approximately 0.5, 1, and 2 Hz. Eye movement recordings were obtained using magnetic scleral search coils in each eye in darkness and during monocular viewing in light. Static torsional VOR gains, defined as change in torsional eye position divided by change in head position during sustained head roll, were also measured. In all patients, horizontal VOR gains in darkness were decreased in the paretic eye in both abduction and adduction, but remained normal in the nonparetic eye in both directions. In light, horizontal visually enhanced VOR (VVOR) gains were normal in both eyes in moderate and mild palsy. In severe palsy, horizontal VVOR gains remained low in the paretic eye during viewing with either eye, whereas those in the nonparetic eye were higher than normal when the paretic eye viewed. Vertical VOR and VVOR were normal, but dynamic and static torsional VOR and VVOR gains were reduced in both eyes in all patients. In darkness, horizontal VOR gains were reduced during abduction of the paretic eye in all patients, as anticipated in sixth nerve palsy. Gains were also reduced during adduction of the paretic eye, suggesting that innervation to the medial rectus has changed. After severe palsy, vision did not increase abducting or adducting horizontal VVOR gains to normal in the paretic eye, but caused secondary increase in VVOR gains to values above unity in the nonparetic eye, when the paretic eye fixated. In mild and moderate palsy, vision enhanced the VOR in the paretic eye but caused no change in the nonparetic eye, suggesting a monocular readjustment of innervation selectively to the paretic eye. Vertical VOR and VVOR gains were normal, indicating that the lateral rectus did not have significant vertical actions through the excursions that we tested (+/-10 degrees ). Reduced torsional VOR gains in the paretic eye can be explained by the esotropia in sixth nerve palsy. Torsional VOR gain normally varies with vergence. We attribute the reduced torsional gains in the paretic eye to the mechanism that normally lowers it during convergence. The low torsional gains in the nonparetic eye may be an adaptation to reduce torsional disparity between the two eyes.
Outcomes of intense pulsed light therapy for treatment of evaporative dry eye disease.
Gupta, Preeya K; Vora, Gargi K; Matossian, Cynthia; Kim, Michelle; Stinnett, Sandra
2016-08-01
To determine the clinical outcomes of intense pulsed light (IPL) therapy for the treatment of evaporative dry eye disease (DED). Multicentre cohort study. Patients with a diagnosis of meibomian gland dysfunction (MGD) and dry eye presenting to the ophthalmology clinic at either the Duke Eye Center, Durham, NC, or Matossian Eye Associates' private practice in Pennington, NJ, and Doylestown, PA. Clinical data were reviewed from 100 patients with diagnosis of MGD and DED who underwent IPL therapy from September 2012 through December 2014 at 1 of 2 centres (Duke Eye Center or Matossian Eye Associates). Demographics, clinical history, examination findings (eyelid and facial vascularity, eyelid margin edema, meibomian gland oil flow, and quality score-all graded on a scale of 0 to 4), tear break up time (TBUT), and ocular surface disease index (OSDI) scoring data were collected from each visit. On average, patients underwent 4 IPL sessions. There was significant decrease in scoring of lid margin edema (mean = -0.3; range -1.5 to 0), facial telangiectasia (mean = -0.7; range -2.5 to 0), lid margin vascularity (mean = -1.2; range -2.5 to 0), meibum viscosity (mean = -1.1; range -3 to 0), and OSDI score (mean = -9.6), all with p < 0.001. There was a significant increase in oil flow score (mean = 0.9, range -0.5 to 2) and TBUT (mean = 3.4 seconds, range -2 to 7), both p < 0.001. No significant changes in intraocular pressure or acuity were noted. There were no cases of adverse ocular effects. IPL therapy for evaporative DED is a safe procedure. The positive change in objective clinical examination findings and subjective OSDI scoring data suggest that IPL is an effective treatment for patients with evaporative DED. Copyright © 2016 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.
Hastings, Gareth D.; Marsack, Jason D.; Nguyen, Lan Chi; Cheng, Han; Applegate, Raymond A.
2017-01-01
Purpose To prospectively examine whether using the visual image quality metric, visual Strehl (VSX), to optimise objective refraction from wavefront error measurements can provide equivalent or better visual performance than subjective refraction and which refraction is preferred in free viewing. Methods Subjective refractions and wavefront aberrations were measured on 40 visually-normal eyes of 20 subjects, through natural and dilated pupils. For each eye a sphere, cylinder, and axis prescription was also objectively determined that optimised visual image quality (VSX) for the measured wavefront error. High contrast (HC) and low contrast (LC) logMAR visual acuity (VA) and short-term monocular distance vision preference were recorded and compared between the VSX-objective and subjective prescriptions both undilated and dilated. Results For 36 myopic eyes, clinically equivalent (and not statistically different) HC VA was provided with both the objective and subjective refractions (undilated mean ±SD was −0.06 ±0.04 with both refractions; dilated was −0.05 ±0.04 with the objective, and −0.05 ±0.05 with the subjective refraction). LC logMAR VA provided by the objective refraction was also clinically equivalent and not statistically different to that provided by the subjective refraction through both natural and dilated pupils for myopic eyes. In free viewing the objective prescription was preferred over the subjective by 72% of myopic eyes when not dilated. For four habitually undercorrected high hyperopic eyes, the VSX-objective refraction was more positive in spherical power and VA poorer than with the subjective refraction. Conclusions A method of simultaneously optimising sphere, cylinder, and axis from wavefront error measurements, using the visual image quality metric VSX, is described. In myopic subjects, visual performance, as measured by HC and LC VA, with this VSX-objective refraction was found equivalent to that provided by subjective refraction, and was typically preferred over subjective refraction. Subjective refraction was preferred by habitually undercorrected hyperopic eyes. PMID:28370389
[The relations of corneal, lenticular and total astigmatism].
Liang, D; Guan, Z; Lin, J
1995-06-01
To determine the relations of corneal, lenticular and total astigmatism and the changes of the astigmatism with age. Out-patients with refractive errors were refracted with retinoscope after using cycloplegic drops and measured the radii of anterior corneal curvature. One hundred and ninety-four cases (382 eyes) with refractive errors were studied. Of the eyes 67.9% had regular corneal astigmatism, 68.1% irregular lenticular astigmatism and 60.7% regular total astigmatism, 88.5% of the corneal astigmatism has the same quality as the total astigmatism. The total astigmatism in 46% of the eyes included the summation of corneal and lenticular astigmatism, but in 41.3% of the eyes irregular lenticular astigmatism corrected the regular corneal astigmatism. The astigmatism of cornea, lens and total astigmatism changed from regular to irregular with the increase of age. The linear correlation analysis showed a positive correlation between the power of horizontal corneal refraction and age, and a negative corrlation between the power of vertical corneal refraction and age. The shape of cornea was the major cause of total astigmatism. The influence of lens on the total astigmatism was different. The reasons for the change of the total astigmatism from regular to irregular with the increase of age were the changes of the power of corneal refraction, particularly the increase of the power of horizontal corneal refraction and lenticular irregular astigmatism.
De Sá Teixeira, Nuno Alexandre
2016-09-01
The memory for the final position of a moving object which suddenly disappears has been found to be displaced forward, in the direction of motion, and downwards, in the direction of gravity. These phenomena were coined, respectively, Representational Momentum and Representational Gravity. Although both these and similar effects have been systematically linked with the functioning of internal representations of physical variables (e.g. momentum and gravity), serious doubts have been raised for a cognitively based interpretation, favouring instead a major role of oculomotor and perceptual factors which, more often than not, were left uncontrolled and even ignored. The present work aims to determine the degree to which Representational Momentum and Representational Gravity are epiphenomenal to smooth pursuit eye movements. Observers were required to indicate the offset locations of targets moving along systematically varied directions after a variable imposed retention interval. Each participant completed the task twice, varying the eye movements' instructions: gaze was either constrained or left free to track the targets. A Fourier decomposition analysis of the localization responses was used to disentangle both phenomena. The results show unambiguously that constraining eye movements significantly eliminates the harmonic components which index Representational Momentum, but have no effect on Representational Gravity or its time course. The found outcomes offer promising prospects for the study of the visual representation of gravity and its neurological substrates.
Silicheva, Margarita; Golovnin, Anton; Pomerantseva, Ekaterina; Parshikov, Aleksander; Georgiev, Pavel; Maksimenko, Oksana
2010-01-01
The white gene, which is responsible for eye pigmentation, is widely used to study position effects in Drosophila. As a result of insertion of P-element vectors containing mini-white without enhancers into random chromosomal sites, flies with different eye color phenotypes appear, which is usually explained by the influence of positive/negative regulatory elements located around the insertion site. We found that, in more than 70% of cases when mini-white expression was subject to positive position effects, deletion of the white promoter had no effect on eye pigmentation; in these cases, the transposon was inserted into the transcribed regions of genes. Therefore, transcription through the mini-white gene could be responsible for high levels of its expression in most of chromosomal sites. Consistently with this conclusion, transcriptional terminators proved to be efficient in protecting mini-white expression from positive position effects. On the other hand, the best characterized Drosophila gypsy insulator was poorly effective in terminating transcription and, as a consequence, only partially protected mini-white expression from these effects. Thus, to ensure maximum protection of a transgene from position effects, a perfect boundary/insulator element should combine three activities: to block enhancers, to provide a barrier between active and repressed chromatin, and to terminate transcription. PMID:19854952
[Webino syndrome caused by meningovascular syphilis. A rare entity with an unexpected cause].
Rodríguez Calvo de Mora, M; Rodríguez Moreno, G; España Contreras, M
2014-05-01
The patient is a 57-year-old obese and hypertensive male. His chief complaints were double vision and dizziness, with mild exodeviation in both eyes in primary gaze position in the ocular motility examination, but more predominant in the left eye. The exotropia was noticeably more evident on the attempted upgaze. On horizontal gaze, the abducting eye deviated fully, but the adducting eye did not cross the midline. Nystagmus in the abducting eye and convergence impairment were found. Pupil size and testing were normal. Ataxia and areflexia were also present. Bilateral internuclear ophthalmoplegia was suspected and imaging and laboratory tests were performed. The CAT scan showed a right occipital hypo-attenuated lesion. In the MRI scan, a mesencephalic subacute ischemic lesion was found, involving the medial rectus sub-nuclei. Blood and cerebrospinal fluid test for syphilis were positive. Bilateral internuclear ophthalmoplegia is a very uncommon -and difficult to diagnose- condition. In the reported case the lesion involved the medial rectus sub-nuclei. This fact could explain the exotropia in the primary gaze position, and supports that is not possible to exclude the involvement of the medial rectus sub-nuclei in the webino syndrome. The rapid identification of the pathology contributed to the better prognosis of the patient. Copyright © 2012 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.
An Exploration of Cognitive Agility as Quantified by Attention Allocation in a Complex Environment
2017-03-01
quantified by eye-tracking data collected while subjects played a military-relevant cognitive agility computer game (Make Goal), to determine whether...subjects played a military-relevant cognitive agility computer game (Make Goal), to determine whether certain patterns are associated with effective...Group and Control Group on Eye Tracking and Game Performance .....................36 3. Comparison between High and Low Performers on Eye tracking and
An automatic eye detection and tracking technique for stereo video sequences
NASA Astrophysics Data System (ADS)
Paduru, Anirudh; Charalampidis, Dimitrios; Fouts, Brandon; Jovanovich, Kim
2009-05-01
Human-computer interfacing (HCI) describes a system or process with which two information processors, namely a human and a computer, attempt to exchange information. Computer-to-human (CtH) information transfer has been relatively effective through visual displays and sound devices. On the other hand, the human-tocomputer (HtC) interfacing avenue has yet to reach its full potential. For instance, the most common HtC communication means are the keyboard and mouse, which are already becoming a bottleneck in the effective transfer of information. The solution to the problem is the development of algorithms that allow the computer to understand human intentions based on their facial expressions, head motion patterns, and speech. In this work, we are investigating the feasibility of a stereo system to effectively determine the head position, including the head rotation angles, based on the detection of eye pupils.
Correlation between acute conjunctivitis and Asian dust on ocular surfaces.
Ko, Ryota; Hayashi, Masahiko; Hayashi, Hideyuki; Hayashi, Kazue; Kato, Hitoshi; Kurata, Yoshinori; Fuchino, Yuki; Nakamichi, Toshifumi; Migita, Hironori; Yano, Hiroko; Sakata, Tetsuya; Uchio, Eiichi
2016-01-01
The aim of this study was to determine the presence of Asian dust particles (ADP) in patients suffering from conjunctivitis and its correlation with clinical scores for conjunctivitis. Forty-five patients from the Fukuoka area who were newly diagnosed acute conjunctivitis were selected. The degrees of inflammatory reaction, itchy sensation, hyperemia, eye discharge, and foreign body sensation were clinically recorded and scored. Eyes were washed with physiological solution. Solid particles collected from the washing solution were observed using a scanning electron microscope. Of the 45 samples, 44 were positive for the elements silicon (Si) and aluminum (Al), which are components of ambient Asian dust. Higher conjunctivitis scores were found in the subgroup in which the Asian dust/whole particle ratio was greater than average. This is the first apparent report on the correlation between amount of ADP exposure at the ocular surface and severity of ocular symptoms.
Fairhall, Sarah J; Dickson, Carol A; Scott, Leah; Pearce, Peter C
2006-04-01
A non-invasive model has been developed to estimate gaze direction and relative pupil diameter, in minimally restrained rhesus monkeys, to investigate the effects of low doses of ocularly administered cholinergic compounds on visual performance. Animals were trained to co-operate with a novel device, which enabled eye movements to be recorded using modified human eye-tracking equipment, and to perform a task which determined visual threshold contrast. Responses were made by gaze transfer under twilight conditions. 4% w/v pilocarpine nitrate was studied to demonstrate the suitability of the model. Pilocarpine induced marked miosis for >3 h which was accompanied by a decrement in task performance. The method obviates the need for invasive surgery and, as the position of point of gaze can be approximately defined, the approach may have utility in other areas of research involving non-human primates.
Positive mood broadens visual attention to positive stimuli.
Wadlinger, Heather A; Isaacowitz, Derek M
2006-03-01
In an attempt to investigate the impact of positive emotions on visual attention within the context of Fredrickson's (1998) broaden-and-build model, eye tracking was used in two studies to measure visual attentional preferences of college students (n=58, n=26) to emotional pictures. Half of each sample experienced induced positive mood immediately before viewing slides of three similarly-valenced images, in varying central-peripheral arrays. Attentional breadth was determined by measuring the percentage viewing time to peripheral images as well as by the number of visual saccades participants made per slide. Consistent with Fredrickson's theory, the first study showed that individuals induced into positive mood fixated more on peripheral stimuli than did control participants; however, this only held true for highly-valenced positive stimuli. Participants under induced positive mood also made more frequent saccades for slides of neutral and positive valence. A second study showed that these effects were not simply due to differences in emotional arousal between stimuli. Selective attentional broadening to positive stimuli may act both to facilitate later building of resources as well as to maintain current positive affective states.
42 CFR 485.643 - Condition of participation: Organ, tissue, and eye procurement.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 5 2011-10-01 2011-10-01 false Condition of participation: Organ, tissue, and eye... participation: Organ, tissue, and eye procurement. The CAH must have and implement written protocols that: (a... absence of alternative arrangements by the CAH, the OPO determines medical suitability for tissue and eye...
42 CFR 485.643 - Condition of participation: Organ, tissue, and eye procurement.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 5 2010-10-01 2010-10-01 false Condition of participation: Organ, tissue, and eye... participation: Organ, tissue, and eye procurement. The CAH must have and implement written protocols that: (a... absence of alternative arrangements by the CAH, the OPO determines medical suitability for tissue and eye...
Likelihood ratios for glaucoma diagnosis using spectral-domain optical coherence tomography.
Lisboa, Renato; Mansouri, Kaweh; Zangwill, Linda M; Weinreb, Robert N; Medeiros, Felipe A
2013-11-01
To present a methodology for calculating likelihood ratios for glaucoma diagnosis for continuous retinal nerve fiber layer (RNFL) thickness measurements from spectral-domain optical coherence tomography (spectral-domain OCT). Observational cohort study. A total of 262 eyes of 187 patients with glaucoma and 190 eyes of 100 control subjects were included in the study. Subjects were recruited from the Diagnostic Innovations Glaucoma Study. Eyes with preperimetric and perimetric glaucomatous damage were included in the glaucoma group. The control group was composed of healthy eyes with normal visual fields from subjects recruited from the general population. All eyes underwent RNFL imaging with Spectralis spectral-domain OCT. Likelihood ratios for glaucoma diagnosis were estimated for specific global RNFL thickness measurements using a methodology based on estimating the tangents to the receiver operating characteristic (ROC) curve. Likelihood ratios could be determined for continuous values of average RNFL thickness. Average RNFL thickness values lower than 86 μm were associated with positive likelihood ratios (ie, likelihood ratios greater than 1), whereas RNFL thickness values higher than 86 μm were associated with negative likelihood ratios (ie, likelihood ratios smaller than 1). A modified Fagan nomogram was provided to assist calculation of posttest probability of disease from the calculated likelihood ratios and pretest probability of disease. The methodology allowed calculation of likelihood ratios for specific RNFL thickness values. By avoiding arbitrary categorization of test results, it potentially allows for an improved integration of test results into diagnostic clinical decision making. Copyright © 2013. Published by Elsevier Inc.
Park, H-Yl; Hwang, Y S; Park, C K
2017-04-01
PurposeTo investigate the clinical characteristics according to the location of focal lamina cribrosa (LC) defects and its associated ocular features.Patients and methodsA total of 139 open-angle glaucoma patients underwent Spectralis optical coherence tomography (OCT) with enhanced depth imaging. Alterations in the contour of the LC were investigated to find focal LC defects. The location of the visible LC defect from the neural canal wall (far-peripheral and mid-peripheral) and clock-hour position (superotemporal, temporal and inferotemporal) were classified. Disc ovality ratio and disc-foveal angle were measured from disc and retinal nerve fiber layer (RNFL) photographs. The disc tilt degree was measured using a Heidelberg Retina Tomograph (HRT) III system. The en face OCT image of the disc scans was registered to the disc and RNFL photographs, to determine whether the focal LC defects corresponded spatially to the glaucomatous damage location.ResultsEyes with far-peripheral LC defects were significantly myopic and had a higher disc ovality ratio. The disc tilt degree obtained by HRT revealed significant temporal disc tilt in eyes with temporal LC defects (P<0.001). Eyes with inferotemporal LC defects had a significantly larger disc-foveal angle (P=0.027). The inferotemporal LC defects corresponded to the location of glaucomatous damage in 81.6%; however, only 46.2% of eyes with a superotemporal LC defect and 3.2% of eyes with a temporal LC defect corresponded spatially with the glaucomatous damage location.ConclusionsThe clinical characteristics and association with glaucomatous damage location were different according to the location of focal LC defect.
Hori, Yuichi; Kageyama, Tomofumi; Sakamoto, Asuka; Shiba, Tomoaki; Nakamura, Masatsugu; Maeno, Takatoshi
To investigate the short-term effects of 2 new secretagogue eye drops for dry eye, 3% diquafosol tetrasodium ophthalmic solution (diquafosol) and 2% rebamipide ophthalmic suspension (rebamipide), on the concentration of mucin 5AC (MUC5AC) in rabbit tear fluid and conjunctival goblet cells. One dose of artificial tears, diquafosol or rebamipide, was instilled into 8 eyes of Japanese white rabbits. MUC5AC concentration in the tear fluid was examined using the enzyme-linked immunosorbent assay 15 min after instillation and compared with 8 untreated controls. Impression cytology was performed to measure the number of periodic acid Schiff (PAS)-positive cells and the ratio of the PAS-positive area using image analysis software. Statistical comparison was performed using ANOVA with post hoc analysis with the Tukey's test. After 15 min, only diquafosol significantly (P ≤ 0.01) increased the MUC5AC level in the tear fluid. Although no drug affected the number of PAS-positive cells, the ratio of the PAS-positive area decreased significantly (P ≤ 0.01) only in the diquafosol group. These data indicated that more PAS-positive MUC5AC was released into the tear fluid from the goblet cells by diquafosol than by rebamipide. There is a difference in the induction pattern of MUC5AC into the tears from the goblet cells between these eye drops.
Kong, Y; Struelens, L; Vanhavere, F; Vargas, C S; Schoonjans, W; Zhuo, W H
2015-02-01
More and more anaesthetists are getting involved in interventional radiology procedures and so it is important to know the radiation dose and to optimise protection for anaesthetists. In this study, based on Monte Carlo simulations and field measurements, both the whole-body doses and eye lens dose of anaesthetists were studied. The results showed that the radiation exposure to anaesthetists not only depends on their workload, but also largely varies with their standing positions and beam projections during interventional procedures. The simulation results showed that the effective dose to anaesthetists may vary with their standing positions and beam projections to more than a factor of 10, and the eye lens dose may vary with the standing positions and beam projections to more than a factor of 200. In general, a close position to the bed and the left lateral (LLAT) beam projection will bring a high exposure to anaesthetists. Good correlations between the eye lens dose and the doses at the neck, chest and waist over the apron were observed from the field measurements. The results indicate that adequate arrangements of anaesthesia device or other monitoring equipment in the fluoroscopy rooms are useful measures to reduce the radiation exposure to anaesthetists, and anaesthetists should be aware that they will receive the highest doses under left lateral beam projection. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Influence of Near-Segment Positioning in a Rotationally Asymmetric Multifocal Intraocular Lens.
Song, In Seok; Yoon, Sam Young; Kim, Jae Yong; Kim, Myoung Joon; Tchah, Hungwon
2016-04-01
To compare visual performance and higher order aberrations (HOAs) based on the position of the near segment in eyes with rotationally asymmetric multifocal intraocular lenses (IOLs). Asymmetric multifocal IOLs (Lentis Mplus LS-313; Oculentis Optikgeräte GmbH, Wetzlar, Germany) were implanted with the near segment positioned either inferiorly, superiorly, or temporally. Uncorrected distance (UDVA), intermediate (UIVA), and near (UNVA) visual acuity, corrected distance visual acuity (CDVA), and distance-corrected intermediate (DCIVA) and near (DCNVA) visual acuity, contrast sensitivity, HOAs, and subjective symptom questionnaires were compared at 1 month postoperatively. Forty-five eyes from 45 patients were evaluated (n = 25, 9, and 11 eyes in the inferior, superior, and temporal groups, respectively). No significant differences in UDVA, UIVA, UNVA, CDVA, DCIVA, or DCNVA were found between the three groups (P > .05). The temporal group showed the best results in UDVA, CDVA, and DCNVA, but the inferior group showed the best results in DCIVA and UNVA and the superior group showed the best results in UIVA. Contrast sensitivity and the subjective symptom questionnaire also did not demonstrate any significant differences (P > .05). Total HOA and spherical aberration did not demonstrate any statistically significant differences (P > .05), but vertical coma and horizontal coma demonstrated significant differences based on near segment position (P < .001). The position of the near segment in eyes with rotationally asymmetric multifocal IOLs demonstrates no significant effect on visual performance. Copyright 2016, SLACK Incorporated.
[Pathogenetic relationship between pterygium and dry eye syndrome (clinical and cytological study)].
Petraevskiĭ, A V; Trishkin, K S
2014-01-01
To study the prevalence of dry eye syndrome in patients with initial primary pterygium for determination of a possible pathogenetic role of dry eye syndrome in the development of pterygium. 30 patients with initial primary pterygium; besides conventional ophthalmic assessment, cytological examination of bulbar conjunctiva was performed in all cases. Signs of dry eye syndrome, of similar severity in both eyes, were found in 100% of patients. Dry eye can be one of the precipitating factors of primary pterygium.
Wroblewska, Katarzyna; Kucinska, Małgorzata; Murias, Marek; Lulek, Janina
2015-09-01
The aim of our study was to examine the irritation potential of new eye drops containing 2% choline salicylate (CS) as an active pharmaceutical ingredient (API) and various polymers increasing eye drop viscosity (hydroxyethylcellulose, hydroxypropyl methylcellulose, methylcellulose, polyvinyl alcohol, polyvinylpyrrolidone). The standard method for assessing the potential of irritating substances has been the Draize rabbit eye test. However the European Centre for Validation of Alternative Methods and the Coordinating Committee for Validation of Alternative Methods recommend, short time exposure (STE) in vitro tests as an alternative method for assessing eye irritation. The eye irritation potential was determined using cytotoxicity test methods for rabbit corneal cell line (SIRC) after 5 min exposure. The viability of cells was determined using two cytotoxicity assays: MTT and Neutral Red Uptake. According to the irritation rankings for the short time exposure test, all tested eye drops are classified as non-irritating (cell viability >70%).
Wroblewska, Katarzyna; Kucinska, Małgorzata; Murias, Marek; Lulek, Janina
2014-01-01
The aim of our study was to examine the irritation potential of new eye drops containing 2% choline salicylate (CS) as an active pharmaceutical ingredient (API) and various polymers increasing eye drop viscosity (hydroxyethylcellulose, hydroxypropyl methylcellulose, methylcellulose, polyvinyl alcohol, polyvinylpyrrolidone). The standard method for assessing the potential of irritating substances has been the Draize rabbit eye test. However the European Centre for Validation of Alternative Methods and the Coordinating Committee for Validation of Alternative Methods recommend, short time exposure (STE) in vitro tests as an alternative method for assessing eye irritation. The eye irritation potential was determined using cytotoxicity test methods for rabbit corneal cell line (SIRC) after 5 min exposure. The viability of cells was determined using two cytotoxicity assays: MTT and Neutral Red Uptake. According to the irritation rankings for the short time exposure test, all tested eye drops are classified as non-irritating (cell viability >70%). PMID:27134543
Kaur, Gurvinder; Koshy, Jacob; Thomas, Satish; Kapoor, Harpreet; Zachariah, Jiju George; Bedi, Sahiba
2016-04-01
Early detection and treatment of vision problems in children is imperative to meet the challenges of childhood blindness. Considering the problems of inequitable distribution of trained manpower and limited access of quality eye care services to majority of our population, innovative community based strategies like 'Teachers training in vision screening' need to be developed for effective utilization of the available human resources. To evaluate the effectiveness of introducing teachers as the first level vision screeners. Teacher training programs were conducted for school teachers to educate them about childhood ocular disorders and the importance of their early detection. Teachers from government and semi-government schools located in Ludhiana were given training in vision screening. These teachers then conducted vision screening of children in their schools. Subsequently an ophthalmology team visited these schools for re-evaluation of children identified with low vision. Refraction was performed for all children identified with refractive errors and spectacles were prescribed. Children requiring further evaluation were referred to the base hospital. The project was done in two phases. True positives, false positives, true negatives and false negatives were calculated for evaluation. In phase 1, teachers from 166 schools underwent training in vision screening. The teachers screened 30,205 children and reported eye problems in 4523 (14.97%) children. Subsequently, the ophthalmology team examined 4150 children and confirmed eye problems in 2137 children. Thus, the teachers were able to correctly identify eye problems (true positives) in 47.25% children. Also, only 13.69% children had to be examined by the ophthalmology team, thus reducing their work load. Similarly, in phase 2, 46.22% children were correctly identified to have eye problems (true positives) by the teachers. By random sampling, 95.65% children were correctly identified as normal (true negatives) by the teachers. Considering the high true negative rates and reasonably good true positive rates and the wider coverage provided by the program, vision screening in schools by teachers is an effective method of identifying children with low vision. This strategy is also valuable in reducing the workload of the eye care staff.
Kappa angles in different positions in patients with myopia during LASIK
Qi, Hui; Jiang, Jing-Jing; Jiang, Yan-Ming; Wang, Li-Qiang; Huang, Yi-Fei
2016-01-01
AIM To investigate the difference in kappa angle between sitting and supine positions during laser-assisted in situ keratomileusis (LASIK). METHODS A retrospective study was performed on 395 eyes from 215 patients with myopia that received LASIK. Low, moderate, and high myopia groups were assigned according to diopters. The horizontal and vertical components of kappa angle in sitting position were measured before the operation, and in supine position during the operation. The data from the two positions were compared and the relationship between kappa angle and diopters were analyzed. RESULTS Two hundred and twenty-three eyes (56.5%) in sitting position and 343 eyes (86.8%) in supine position had positive kappa angles. There were no significant differences in horizontal and vertical components of kappa angle in the sitting position or horizontal components of kappa angle in the supine position between the three groups (P>0.05). A significant difference in the vertical components of kappa angle in the supine position was seen in the three groups (P<0.01). Differences in both horizontal and vertical components of kappa angles were significant between the sitting and supine positions. Positive correlations in both horizontal and vertical components of kappa angles (P<0.05) were found and vertical components of kappa angle in sitting and supine positions were negatively correlated with the degree of myopia (sitting position: r=-0.109; supine position: r=-0.172; P<0.05). CONCLUSION There is a correlation in horizontal and vertical components of kappa angle in sitting and supine positions. Positive correlations in both horizontal and vertical components of kappa angle in sitting and supine positions till the end of the results. This result still needs further observation. Clinicians should take into account different postures when excimer laser surgery needs to be performed. PMID:27162734
Takeda, Noriaki; Uno, Atsuhiko; Inohara, Hidenori; Shimada, Shoichi
2016-01-01
Background The mouse is the most commonly used animal model in biomedical research because of recent advances in molecular genetic techniques. Studies related to eye movement in mice are common in fields such as ophthalmology relating to vision, neuro-otology relating to the vestibulo-ocular reflex (VOR), neurology relating to the cerebellum’s role in movement, and psychology relating to attention. Recording eye movements in mice, however, is technically difficult. Methods We developed a new algorithm for analyzing the three-dimensional (3D) rotation vector of eye movement in mice using high-speed video-oculography (VOG). The algorithm made it possible to analyze the gain and phase of VOR using the eye’s angular velocity around the axis of eye rotation. Results When mice were rotated at 0.5 Hz and 2.5 Hz around the earth’s vertical axis with their heads in a 30° nose-down position, the vertical components of their left eye movements were in phase with the horizontal components. The VOR gain was 0.42 at 0.5 Hz and 0.74 at 2.5 Hz, and the phase lead of the eye movement against the turntable was 16.1° at 0.5 Hz and 4.88° at 2.5 Hz. Conclusions To the best of our knowledge, this is the first report of this algorithm being used to calculate a 3D rotation vector of eye movement in mice using high-speed VOG. We developed a technique for analyzing the 3D rotation vector of eye movements in mice with a high-speed infrared CCD camera. We concluded that the technique is suitable for analyzing eye movements in mice. We also include a C++ source code that can calculate the 3D rotation vectors of the eye position from two-dimensional coordinates of the pupil and the iris freckle in the image to this article. PMID:27023859
Hsu, S L; Lee, P Y; Chang, C H; Chen, C H
2016-08-30
Thyroid orbitopathy (TO) is an autoimmune disease that is complicated by ocular surface disorders, leading to discomfort. Dry eye is very prevalent in patients with TO. Recent studies on the pathogenesis of dry eye have focused on the inflammatory process, and some supporting evidence has been discovered. Because TO is a disorder of autoimmune origin, we assumed that the association between TO and dry eye is related to inflammation. Inflammation of the ocular surface in TO-related dry eye has not been well studied. In this study, we assessed cellular inflammation of the ocular surface and the cytokine profiles in patients with TO-related dry eye. Conjunctival impression cytology (CIC) was assessed with an immunofluorescent assay. TO-related dry eye was diagnosed by using the Schirmer test, tear break-up time, thyroid function, and clinical signs. CIC was combined with immunological staining of interleukin-1a (IL-1a), IL-1b, and IL- 6. The immunological impression cytology (IC) grade was compared to the clinical activity score of TO. All TO patients with dry eye were positive for IL-1a, IL-1b, and IL-6. However, the normal controls were also positive for IL-1a. A trend was observed between the clinical inflammatory score and immunological IC grade. This study was the first to delineate the immunological IC of TO-related dry eye. Our study aimed to investigate the pathogenesis of dry eye in TO. Our findings suggest that the conjunctival cytokines IL-1a, IL-1b, and IL-6 may play a role. The results of this study will be useful for future studies of additional inflammatory cytokines, and the levels of these cytokines could be used as an outcome to assess the efficacy of treatment, such as anti-cytokine or immunosuppression therapy, in patients with TO-related dry eye or other ocular surface inflammatory disorders.
Barrett, Brendan T.; Panesar, Gurvinder K.; Scally, Andrew J.; Pacey, Ian E.
2013-01-01
Background Adults with amblyopia (‘lazy eye’), long-standing strabismus (ocular misalignment) or both typically do not experience visual symptoms because the signal from weaker eye is given less weight than the signal from its fellow. Here we examine the contribution of the weaker eye of individuals with strabismus and amblyopia with both eyes open and with the deviating eye in its anomalous motor position. Methodology/Results The task consisted of a blue-on-yellow detection task along a horizontal line across the central 50 degrees of the visual field. We compare the results obtained in ten individuals with strabismic amblyopia with ten visual normals. At each field location in each participant, we examined how the sensitivity exhibited under binocular conditions compared with sensitivity from four predictions, (i) a model of binocular summation, (ii) the average of the monocular sensitivities, (iii) dominant-eye sensitivity or (iv) non-dominant-eye sensitivity. The proportion of field locations for which the binocular summation model provided the best description of binocular sensitivity was similar in normals (50.6%) and amblyopes (48.2%). Average monocular sensitivity matched binocular sensitivity in 14.1% of amblyopes’ field locations compared to 8.8% of normals’. Dominant-eye sensitivity explained sensitivity at 27.1% of field locations in amblyopes but 21.2% in normals. Non-dominant-eye sensitivity explained sensitivity at 10.6% of field locations in amblyopes but 19.4% in normals. Binocular summation provided the best description of the sensitivity profile in 6/10 amblyopes compared to 7/10 of normals. In three amblyopes, dominant-eye sensitivity most closely reflected binocular sensitivity (compared to two normals) and in the remaining amblyope, binocular sensitivity approximated to an average of the monocular sensitivities. Conclusions Our results suggest a strong positive contribution in habitual viewing from the non-dominant eye in strabismic amblyopes. This is consistent with evidence from other sources that binocular mechanisms are frequently intact in strabismic and amblyopic individuals. PMID:24205005
Olsen, Timothy W; Bottini, Alexander R; Mendoza, Pia; Grossniklausk, Hans E
2015-09-01
To describe the histopathologic findings of the four stages of age-related macular degeneration (AMD) as defined by the Age-Related Eye Disease Study (AREDS) using the Minnesota grading system (MGS). There are no animal models for AMD. Eye banks enable access to human tissue with AMD. The level of AMD (grades 1 through 4) as defined by AREDS is determined ex vivo using the MGS. The AREDS has the largest collection to date of prospectively gathered data on the natural history of AMD. Since the MGS uses the same clinical criteria as AREDS, the addition of histopathologic findings of graded tissue confirms important pathophysiology at each stage of AMD. Four eye bank eyes were graded according to the MGS. Only the right eyes were dissected for phenotype grading. The fellow (left) eyes were fixed for histopathologic study. The eyes were serially sectioned (7 μm) through the macula. Individual slides were examined, and a two-dimensional reconstruction of the topography of the macula was created for each donor. Selected, unstained slides were used for immunohistochemical staining. In one donor, portions of tissue were obtained for transmission electron microscopic (TEM) processing. Donor 1 had a rare hard, nodular druse (MGS1). Donor 2 had intermediate confluent drusen (MGS2). Donor 3 had numerous intermediate drusen (MGS3) in the right eye. Histopathology of the fellow left showed basal laminar deposits (BLamD), soft drusen, and an area of occult choroidal neovascularization underlying the retinal pigment epithelium (RPE) with endothelial cells (CD31-positive). Donor 4 also had MGS 3 along with reticular pseudodrusen (RPD). Histologic and TEM examination demonstrated diffuse BLamD, thickening of Bruch's membrane, hard drusen, and focal nodules underlying the RPE that corresponded to the RPD. EM examination demonstrated both BLamD and electron-dense material located just external to the elastic layer of Bruch's membrane. Eye bank eyes graded using the MGS serve as an important link to the phenotypic and epidemiologic data from the AREDS. Thus, the MGS serves as a system to study the histopathology at each stage of AMD to better understand the relevant pathophysiologic changes in disease progression.
Olsen, Timothy W.; Bottini, Alexander R.; Mendoza, Pia; Grossniklausk, Hans E.
2015-01-01
Purpose To describe the histopathologic findings of the four stages of age-related macular degeneration (AMD) as defined by the Age-Related Eye Disease Study (AREDS) using the Minnesota grading system (MGS). Clinical Relevance There are no animal models for AMD. Eye banks enable access to human tissue with AMD. The level of AMD (grades 1 through 4) as defined by AREDS is determined ex vivo using the MGS. The AREDS has the largest collection to date of prospectively gathered data on the natural history of AMD. Since the MGS uses the same clinical criteria as AREDS, the addition of histopathologic findings of graded tissue confirms important pathophysiology at each stage of AMD. Methods Four eye bank eyes were graded according to the MGS. Only the right eyes were dissected for phenotype grading. The fellow (left) eyes were fixed for histopathologic study. The eyes were serially sectioned (7 μm) through the macula. Individual slides were examined, and a two-dimensional reconstruction of the topography of the macula was created for each donor. Selected, unstained slides were used for immunohistochemical staining. In one donor, portions of tissue were obtained for transmission electron microscopic (TEM) processing. Results Donor 1 had a rare hard, nodular druse (MGS1). Donor 2 had intermediate confluent drusen (MGS2). Donor 3 had numerous intermediate drusen (MGS3) in the right eye. Histopathology of the fellow left showed basal laminar deposits (BLamD), soft drusen, and an area of occult choroidal neovascularization underlying the retinal pigment epithelium (RPE) with endothelial cells (CD31-positive). Donor 4 also had MGS 3 along with reticular pseudodrusen (RPD). Histologic and TEM examination demonstrated diffuse BLamD, thickening of Bruch’s membrane, hard drusen, and focal nodules underlying the RPE that corresponded to the RPD. EM examination demonstrated both BLamD and electron-dense material located just external to the elastic layer of Bruch’s membrane. Conclusion Eye bank eyes graded using the MGS serve as an important link to the phenotypic and epidemiologic data from the AREDS. Thus, the MGS serves as a system to study the histopathology at each stage of AMD to better understand the relevant pathophysiologic changes in disease progression. PMID:27895380
Harrison, Charlotte; Jackson, Jade; Oh, Seung-Mock; Zeringyte, Vaida
2016-01-01
Multivariate pattern analysis of functional magnetic resonance imaging (fMRI) data is widely used, yet the spatial scales and origin of neurovascular signals underlying such analyses remain unclear. We compared decoding performance for stimulus orientation and eye of origin from fMRI measurements in human visual cortex with predictions based on the columnar organization of each feature and estimated the spatial scales of patterns driving decoding. Both orientation and eye of origin could be decoded significantly above chance in early visual areas (V1–V3). Contrary to predictions based on a columnar origin of response biases, decoding performance for eye of origin in V2 and V3 was not significantly lower than that in V1, nor did decoding performance for orientation and eye of origin differ significantly. Instead, response biases for both features showed large-scale organization, evident as a radial bias for orientation, and a nasotemporal bias for eye preference. To determine whether these patterns could drive classification, we quantified the effect on classification performance of binning voxels according to visual field position. Consistent with large-scale biases driving classification, binning by polar angle yielded significantly better decoding performance for orientation than random binning in V1–V3. Similarly, binning by hemifield significantly improved decoding performance for eye of origin. Patterns of orientation and eye preference bias in V2 and V3 showed a substantial degree of spatial correlation with the corresponding patterns in V1, suggesting that response biases in these areas originate in V1. Together, these findings indicate that multivariate classification results need not reflect the underlying columnar organization of neuronal response selectivities in early visual areas. NEW & NOTEWORTHY Large-scale response biases can account for decoding of orientation and eye of origin in human early visual areas V1–V3. For eye of origin this pattern is a nasotemporal bias; for orientation it is a radial bias. Differences in decoding performance across areas and stimulus features are not well predicted by differences in columnar-scale organization of each feature. Large-scale biases in extrastriate areas are spatially correlated with those in V1, suggesting biases originate in primary visual cortex. PMID:27903637
Speiser, Daniel I.; Gagnon, Yakir Luc; Chhetri, Raghav K.; Oldenburg, Amy L.; Johnsen, Sönke
2016-01-01
The eyes of scallops form images using a concave spherical mirror and contain two separate retinas, one layered on top of the other. Behavioral and electrophysiological studies indicate that the images formed by these eyes have angular resolutions of about 2°. Based on previous ray-tracing models, it has been thought that the more distal of the two retinas lies near the focal point of the mirror and that the proximal retina, positioned closer to the mirror at the back of the eye, receives light that is out-of-focus. Here, we propose three mechanisms through which both retinas may receive focused light: (1) chromatic aberration produced by the lens may cause the focal points for longer and shorter wavelengths to fall near the distal and proximal retinas, respectively; (2) focused light from near and far objects may fall on the distal and proximal retinas, respectively; and (3) the eyes of scallops may be dynamic structures that change shape to determine which retina receives focused light. To test our hypotheses, we used optical coherence tomography (OCT), a method of near-infrared optical depth-ranging, to acquire virtual cross-sections of live, intact eyes from the bay scallop Argopecten irradians. Next, we used a custom-built ray-tracing model to estimate the qualities of the images that fall on an eye’s distal and proximal retinas as functions of the wavelengths of light entering the eye (400–700 nm), object distances (0.01–1 m), and the overall shape of the eye. When we assume 550 nm wavelength light and object distances greater than 0.01 m, our model predicts that the angular resolutions of the distal and proximal retinas are 2° and 7°, respectively. Our model also predicts that neither chromatic aberration nor differences in object distance lead to focused light falling on the distal and proximal retinas simultaneously. However, if scallops can manipulate the shapes of their eyes, perhaps through muscle contractions, we speculate that they may be able to influence the qualities of the images that fall on their proximal retinas and—to a lesser extent—those that fall on their distal retinas as well. PMID:27549200
Roberts, Tawna L; Kester, Kristi N; Hertle, Richard W
2018-04-01
This study presents test-retest reliability of optotype visual acuity (OVA) across 60° of horizontal gaze position in patients with infantile nystagmus syndrome (INS). Also, the validity of the metric gaze-dependent functional vision space (GDFVS) is shown in patients with INS. In experiment 1, OVA was measured twice in seven horizontal gaze positions from 30° left to right in 10° steps in 20 subjects with INS and 14 without INS. Test-retest reliability was assessed using intraclass correlation coefficient (ICC) in each gaze. OVA area under the curve (AUC) was calculated with horizontal eye position on the x-axis, and logMAR visual acuity on the y-axis and then converted to GDFVS. In experiment 2, validity of GDFVS was determined over 40° horizontal gaze by applying the 95% limits of agreement from experiment 1 to pre- and post-treatment GDFVS values from 85 patients with INS. In experiment 1, test-retest reliability for OVA was high (ICC ≥ 0.88) as the difference in test-retest was on average less than 0.1 logMAR in each gaze position. In experiment 2, as a group, INS subjects had a significant increase (P < 0.001) in the size of their GDFVS that exceeded the 95% limits of agreement found during test-retest. OVA is a reliable measure in INS patients across 60° of horizontal gaze position. GDFVS is a valid clinical method to be used to quantify OVA as a function of eye position in INS patients. This method captures the dynamic nature of OVA in INS patients and may be a valuable measure to quantify visual function patients with INS, particularly in quantifying change as part of clinical studies.
Weight effect of saline accumulation in surgical drapes.
Wiggins, Michael N; Thostenson, Jeff D
2007-10-01
Positive vitreal pressure during phacoemulsification is a known risk factor for posterior capsule rupture. Knowledge of modifiable causes of positive vitreal pressure is imperative to aid in its management intraoperatively. The aim of our study was to determine whether the weight from the accumulation of a large volume of saline in the surgical drapes could have an effect on intraocular pressure in patients. Such an effect could indicate a source of posterior vitreal pressure in patients undergoing prolonged phacoemulsification. In 23 adult patients undergoing phacoemulsification at the Jones Eye Institute at the University of Arkansas for Medical Sciences, intraocular pressure readings were taken before and after the addition of 500 cc of saline to the surgical drapes and taken again after removal of the saline. Statistically significant differences in intraocular pressure were found between the baseline measurement, the measurement with saline, and the measurement after saline removal. No differences in the rise in intraocular pressure were found according to age, race, sex, or which eye was tested. Accumulation of a large volume of saline in surgical drapes has a modest effect on intraocular pressure. This may indicate a contributing cause of posterior vitreal pressure during prolonged phacoemulsification.
Pioneers of eye movement research
Wade, Nicholas J
2010-01-01
Recent advances in the technology affording eye movement recordings carry the risk of neglecting past achievements. Without the assistance of this modern armoury, great strides were made in describing the ways the eyes move. For Aristotle the fundamental features of eye movements were binocular, and he described the combined functions of the eyes. This was later given support using simple procedures like placing a finger over the eyelid of the closed eye and culminated in Hering's law of equal innervation. However, the overriding concern in the 19th century was with eye position rather than eye movements. Appreciating discontinuities of eye movements arose from studies of vertigo. The characteristics of nystagmus were recorded before those of saccades and fixations. Eye movements during reading were described by Hering and by Lamare in 1879; both used similar techniques of listening to sounds made during contractions of the extraocular muscles. Photographic records of eye movements during reading were made by Dodge early in the 20th century, and this stimulated research using a wider array of patterns. In the mid-20th century attention shifted to the stability of the eyes during fixation, with the emphasis on involuntary movements. The contributions of pioneers from Aristotle to Yarbus are outlined. PMID:23396982
Topographical analysis of corneal astigmatism in patients with tilted-disc syndrome.
Bozkurt, Banu; Irkec, Murat; Gedik, Sansal; Orhan, Mehmet; Erdener, Uğur
2002-07-01
To evaluate the corneal topography in patients with tilted-disc syndrome to determine the relationship between optic disc dysversion and corneal astigmatism and the pattern of astigmatism in these patients. The study included 23 eyes of the 13 tilted-disc syndrome patients with spheric refractive errors ranging between +1.00 D and -9.00 D (mean -4.00 +/- 3.4 D) and astigmatic errors ranging between -0.50 and -4.50 D (mean -1.95 +/- 0.93 D). Corneal topography was performed by computer-assisted videokeratoscope topographic modelling system 2 (TMS-2) and incidence of corneal astigmatism, corneal topographic patterns, and mean values of the topographic indices were determined. Corneal topographic analysis showed corneal astigmatism in 22 out of 23 patients with tilted discs. Corneal astigmatism was symmetric bow tie pattern in 10 eyes (45.45%), asymmetric bow tie pattern in 11 eyes (50%) and irregular in 1 eye (4.5%). Among the patients with bow tie pattern group (21 eyes), 14 eyes had with-the-rule astigmatism, 1 eye had against-the-rule astigmatism, and 6 eyes had oblique astigmatism. In 18 eyes, astigmatism was corneal, whereas combined corneal and lenticular in 4 eyes and lenticular in 1 eye. In the majority of tilted-disc cases, ocular astigmatism is mainly corneal. Morphogenetic factors in the development of the tilted disc might possibly influence the corneal development in such a way to result in corneal astigmatism.
Eberwein, Philipp; Hansen, Lutz L; Agostini, Hansjürgen T
2005-02-01
JC virus (JCV) is a human polyomavirus that exists in at least eight different genotypes as a result of coevolution with different human populations all over the world. Well adapted to its host, it usually persists in the kidneys and possibly the brain. If the host becomes immunodeficient, JCV can cause the fatal demyelinating disease progressive multifocal leukoencephalopathy (PML). There is increasing evidence that JCV is transactivated by cytomegalovirus (CMV) and the human immunodeficiency virus (HIV). Both CMV and HIV can infect the retina of acquired immunodeficiency syndrome (AIDS) patients, causing severe necrosis in the case of CMV retinitis or a mild HIV-associated vasculopathy, with bleeding and cotton wool spots. The authors therefore investigated by polymerase chain reaction (PCR) whether DNA of these three viruses was detectable in paraffin-embedded eyes of AIDS patients with a clinical history of CMV retinitis. From a total of 65 eyes, JCV was detected in 21 (32%). Thirty-six (55%) were positive for CMV and 6 (9%) for proviral DNA of HIV. JCV and CMV were found in 13 eyes, JCV and HIV in 3 eyes, CMV and HIV in 1 eye, and DNA from all three viruses in 1 eye. The JCV genotypes were types 1A, 2A, 2E, 3, and 4. In 21 eyes of patients without AIDS, only one sample was JCV positive. In conclusion, JCV DNA can be detected in ocular tissue of AIDS patients at a significantly higher level than in eyes of nonimmunosuppressed patients. Further investigations will help to decide if JCV contributes to the retinopathy caused by CMV and HIV.
Parallax barrier engineering for image quality improvement in an autostereoscopic 3D display.
Kim, Sung-Kyu; Yoon, Ki-Hyuk; Yoon, Seon Kyu; Ju, Heongkyu
2015-05-18
We present a image quality improvement in a parallax barrier (PB)-based multiview autostereoscopic 3D display system under a real-time tracking of positions of a viewer's eyes. The system presented exploits a parallax barrier engineered to offer significantly improved quality of three-dimensional images for a moving viewer without an eyewear under the dynamic eye tracking. The improved image quality includes enhanced uniformity of image brightness, reduced point crosstalk, and no pseudoscopic effects. We control the relative ratio between two parameters i.e., a pixel size and the aperture of a parallax barrier slit to improve uniformity of image brightness at a viewing zone. The eye tracking that monitors positions of a viewer's eyes enables pixel data control software to turn on only pixels for view images near the viewer's eyes (the other pixels turned off), thus reducing point crosstalk. The eye tracking combined software provides right images for the respective eyes, therefore producing no pseudoscopic effects at its zone boundaries. The viewing zone can be spanned over area larger than the central viewing zone offered by a conventional PB-based multiview autostereoscopic 3D display (no eye tracking). Our 3D display system also provides multiviews for motion parallax under eye tracking. More importantly, we demonstrate substantial reduction of point crosstalk of images at the viewing zone, its level being comparable to that of a commercialized eyewear-assisted 3D display system. The multiview autostereoscopic 3D display presented can greatly resolve the point crosstalk problem, which is one of the critical factors that make it difficult for previous technologies for a multiview autostereoscopic 3D display to replace an eyewear-assisted counterpart.
Chuk, Tim; Chan, Antoni B; Hsiao, Janet H
2017-12-01
The hidden Markov model (HMM)-based approach for eye movement analysis is able to reflect individual differences in both spatial and temporal aspects of eye movements. Here we used this approach to understand the relationship between eye movements during face learning and recognition, and its association with recognition performance. We discovered holistic (i.e., mainly looking at the face center) and analytic (i.e., specifically looking at the two eyes in addition to the face center) patterns during both learning and recognition. Although for both learning and recognition, participants who adopted analytic patterns had better recognition performance than those with holistic patterns, a significant positive correlation between the likelihood of participants' patterns being classified as analytic and their recognition performance was only observed during recognition. Significantly more participants adopted holistic patterns during learning than recognition. Interestingly, about 40% of the participants used different patterns between learning and recognition, and among them 90% switched their patterns from holistic at learning to analytic at recognition. In contrast to the scan path theory, which posits that eye movements during learning have to be recapitulated during recognition for the recognition to be successful, participants who used the same or different patterns during learning and recognition did not differ in recognition performance. The similarity between their learning and recognition eye movement patterns also did not correlate with their recognition performance. These findings suggested that perceptuomotor memory elicited by eye movement patterns during learning does not play an important role in recognition. In contrast, the retrieval of diagnostic information for recognition, such as the eyes for face recognition, is a better predictor for recognition performance. Copyright © 2017 Elsevier Ltd. All rights reserved.
Luque, M A; Pérez-Pérez, M P; Herrero, L; Waitzman, D M; Torres, B
2006-02-01
Anatomical studies in goldfish show that the tectofugal axons provide a large number of boutons within the mesencephalic reticular formation. Electrical stimulation, reversible inactivation and cell recording in the primate central mesencephalic reticular formation have suggested that it participates in the control of rapid eye movements (saccades). Moreover, the role of this tecto-recipient area in the generation of saccadic eye movements in fish is unknown. In this study we show that the electrical microstimulation of the mesencephalic reticular formation of goldfish evoked short latency saccadic eye movements in any direction (contraversive or ipsiversive, upward or downward). Movements of the eyes were usually disjunctive. Based on the location of the sites from which eye movements were evoked and the preferred saccade direction, eye movements were divided into different groups: pure vertical saccades were mainly elicited from the rostral mesencephalic reticular formation, while oblique and pure horizontal were largely evoked from middle and caudal mesencephalic reticular formation zones. The direction and amplitude of pure vertical and horizontal saccades were unaffected by initial eye position. However the amplitude, but not the direction of most oblique saccades was systematically modified by initial eye position. At the same time, the amplitude of elicited saccades did not vary in any consistent manner along either the anteroposterior, dorsoventral or mediolateral axes (i.e. there was no topographic organization of the mesencephalic reticular formation with respect to amplitude). In addition to these groups of movements, we found convergent and goal-directed saccades evoked primarily from the anterior and posterior mesencephalic reticular formation, respectively. Finally, the metric and kinetic characteristics of saccades could be manipulated by changes in the stimulation parameters. We conclude that the mesencephalic reticular formation in goldfish shares physiological functions that correspond closely with those found in mammals.
The Development of Fine-Grained Sensitivity to Eye Contact after 6 Years of Age
ERIC Educational Resources Information Center
Vida, Mark D.; Maurer, Daphne
2012-01-01
Adults use eye contact as a cue to the mental and emotional states of others. Here, we examined developmental changes in the ability to discriminate between eye contact and averted gaze. Children (6-, 8-, 10-, and 14-year-olds) and adults (n=18/age) viewed photographs of a model fixating the center of a camera lens and a series of positions to the…
[Study of corvitin efficiency in primary glaucoma].
Mykheĭtseva, I M; Kashyntseva, L T; Artemov, O V; Khramenko, N I
2012-01-01
There were concluded our results of animal experimental investigation and clinical observation of the quercetin-containing preparation corvitin (C) in primary glaucoma treatment. On the model of disease it is shown for rabbit, that introduction of 0.5 ml 2 % C as factious instillation into the eye a basely decreased eye blood flow was increased twice, mionectic at glaucoma eye hydrodynamics was normalized : the outflow of liquid increased on 58 %, inflow - on 52 %, intraocular pressure went down on 14%. Intravenous inflowing of C brought down expressed of oxidative stress - M[see text]A in blood is decreased on 40 %, level of endothelial dysfunction marker NO is increased on 70 %. On the model of glaucoma for rats C, entered protractedly, showed the neuroprotective actions on the neurons of retina, promoting survivability of ganglion cells, that it is shown on histological preparations. Application C in the clinic of glaucoma (intravenously a 0.5 g of preparation in 100 ml of solution) improved for patients a blood supply in the eye on 25 %, and also rendered a positive antioxidant and metabolic effect. Noted positive influences of C concurrently to important pathogeneses factors such as regional eye blood supply, eye hydrodynamics, oxidative stress, metabolic changes, survival of retina neurons grounds to talk about new strategy of pathogenesis therapy of glaucoma.
PC-based high-speed video-oculography for measuring rapid eye movements in mice.
Sakatani, Tomoya; Isa, Tadashi
2004-05-01
We newly developed an infrared video-oculographic system for on-line tracking of the eye position in awake and head-fixed mice, with high temporal resolution (240 Hz). The system consists of a commercially available high-speed CCD camera and an image processing software written in LabVIEW run on IBM-PC with a plug-in video grabber board. This software calculates the center and area of the pupil by fitting circular function to the pupil boundary, and allows robust and stable tracking of the eye position in small animals like mice. On-line calculation is performed to obtain reasonable circular fitting of the pupil boundary even if a part of the pupil is covered with shadows or occluded by eyelids or corneal reflections. The pupil position in the 2-D video plane is converted to the rotation angle of the eyeball by estimating its rotation center based on the anatomical eyeball model. By this recording system, it is possible to perform quantitative analysis of rapid eye movements such as saccades in mice. This will provide a powerful tool for analyzing molecular basis of oculomotor and cognitive functions by using various lines of mutant mice.
Parallel programming of saccades during natural scene viewing: evidence from eye movement positions.
Wu, Esther X W; Gilani, Syed Omer; van Boxtel, Jeroen J A; Amihai, Ido; Chua, Fook Kee; Yen, Shih-Cheng
2013-10-24
Previous studies have shown that saccade plans during natural scene viewing can be programmed in parallel. This evidence comes mainly from temporal indicators, i.e., fixation durations and latencies. In the current study, we asked whether eye movement positions recorded during scene viewing also reflect parallel programming of saccades. As participants viewed scenes in preparation for a memory task, their inspection of the scene was suddenly disrupted by a transition to another scene. We examined whether saccades after the transition were invariably directed immediately toward the center or were contingent on saccade onset times relative to the transition. The results, which showed a dissociation in eye movement behavior between two groups of saccades after the scene transition, supported the parallel programming account. Saccades with relatively long onset times (>100 ms) after the transition were directed immediately toward the center of the scene, probably to restart scene exploration. Saccades with short onset times (<100 ms) moved to the center only one saccade later. Our data on eye movement positions provide novel evidence of parallel programming of saccades during scene viewing. Additionally, results from the analyses of intersaccadic intervals were also consistent with the parallel programming hypothesis.
Fogt, Jennifer S; Jones-Jordan, Lisa A; Barr, Joseph T
2018-01-01
New designs of eye wash stations have been developed in which the direction of water flow from the fountain has been reversed, with two water streams originating nasally in both eyes and flowing toward the temporal side of each eye. No study has been done to determine the ideal direction of water flow coming from the eye wash in relation to the eye. Ophthalmic eye examinations were conducted before and after the use of two eye wash stations with opposite water flow directionality. Fluorescein was instilled in both eyes before using an eye wash to measure the effectiveness of the water flow. Subjects were surveyed upon their experiences using the eye washes. Ophthalmic examination found no significant difference in the efficacy of the eye washes with nasal-to-temporal water flow when compared to temporal-to-nasal water flow direction.
Toda, Ikuko
2007-01-01
Dry eye is one of the most common complications after laser-assisted in situ keratomileusis (LASIK). The clinical signs of post-LASIK dry eye include positive vital staining of ocular surface, decreased tear film breakup time and Schirmer test, reduced corneal sensitivity, and decreased functional visual acuity. The symptoms and signs last at least 1 month after LASIK. Although the mechanisms for developing post-LASIK dry eye are not completely understood, loss of corneal innervation by flap-making may affect the reflex loops of the corneal-lacrimal gland, corneal-blinking, and blinking-meibomian gland, and blinking-meibomian gland, resulting in decreased aqueous and lipid tear secretion and mucin expression. As LASIK enhancement by flap-lifting induces less dry eye symptoms and signs than first surgery, it is suggested that other factors rather than loss of neurotrophic effect may be involved in the mechanisms of post-LASIK dry eye. The treatments of dry eye include artificial tears, topical cyclosporine, hot compress, punctal plugs, and autologous serum eye drops. For patients with severe preoperative dry eye, a combination of punctal plugs and serum eye drops is required to be used before surgery.
Supuk, Elvira; Alderson, Alison; Davey, Christopher J; Green, Clare; Litvin, Norman; Scally, Andrew J; Elliott, David B
2016-03-01
To determine whether dizziness and falls rates change due to routine cataract surgery and to determine the influence of spectacle type and refractive factors. Self-reported dizziness and falls were determined in 287 patients (mean age of 76.5 ± 6.3 years, 55% females) before and after routine cataract surgery for the first (81, 28%), second (109, 38%) and both eyes (97, 34%). Dizziness was determined using the short-form of the Dizziness Handicap Inventory. Six-month falls rates were determined using self-reported retrospective data. The number of patients with dizziness reduced significantly after cataract surgery (52% vs 38%; χ(2) = 19.14(,) p < 0.001), but the reduction in the number of patients who fell in the 6-months post surgery was not significant (23% vs 20%; χ(2) = 0.87, p = 0.35). Dizziness improved after first eye surgery (49% vs 33%, p = 0.01) and surgery on both eyes (58% vs 35%, p < 0.001), but not after second eye surgery (52% vs 45%, p = 0.68). Multivariate logistic regression analyses found significant links between post-operative falls and change in spectacle type (increased risk if switched into multifocal spectacles). Post-operative dizziness was associated with changes in best eye visual acuity and changes in oblique astigmatic correction. Dizziness is significantly reduced by first (or both) eye cataract surgery and this is linked with improvements in best eye visual acuity, although changes in oblique astigmatic correction increased dizziness. The lack of improvement in falls rate may be associated with switching into multifocal spectacle wear after surgery. © 2015 The Authors Ophthalmic and Physiological Optics published by John Wiley & Sons Ltd on behalf of College of Optometrists.
Tear osmolarity measurements in dry eye related to primary Sjögren's syndrome.
Utine, Canan Asli; Bıçakçıgil, Müge; Yavuz, Sule; Çiftçi, Ferda
2011-08-01
To evaluate the tear osmolarity in patients with dry eye syndrome related to primary Sjögren's Syndrome (SS). Twenty eyes of 10 patients with dry eye and primary SS (Group 1) and 20 eyes of 20 subjects who do not have dry eye syndrome (Group 2) were included in this cross-sectional study. In all eyes, ophthalmic examination was performed in the same order: International Ocular Surface Disease Index survey, visual acuity assessment, conjunctival hyperemia scoring, tear osmolarity measurement with TearLab(™) Osmolarity System, tear film break-up time assessment, corneal fluorescein staining scoring, ocular surface Lissamine Green staining scoring, anesthetized Schirmer test. Dry eye severity was graded according to Dry Eye Workshop (DEWS) classification system. Four eyes with grade 1, four eyes with grade 2, seven eyes with grade 3, and five eyes with grade 4 dryness, according to DEWS system, were included. The mean tear osmolarity value was 301.9 ± 11.40 mOsm/L (range: 290-328) in Group 1, and 294.85 ± 8.33 mOsm/L (range: 283-311) in Group 2 (p = 0.03). In Group 1, tear osmolarity values were positively correlated with OSDI scores (r(18) = 0.55, r(2) = 0.31, p = 0.01), DEWS classification grades (r(18) = 0.73, r(2) = 0.54, p < 0.01), temporal and total corneal staining scores (r(18) = 0.67, r(2) = 0.44, p < 0.01, and r(18) = 0.51, r(2) = 0.26, p = 0.02, respectively), temporal conjunctival staining scores (r(18) = 58, r(2) = 0.34, p < 0.01); and negatively correlated with anesthetized Schirmer test results (r(18) = -0.62, r(2) = 0.38, p < 0.01) and TFBUT (r(18) = -0.50, r(2) = 0.25, p = 0.02). Tear osmolarity values were found to be greater in patients with dry eye syndrome related to primary SS compared to control subjects, and positively correlated with the severity of dry eye.
Das, Sujata; Sharma, Savitri; Priyadarshini, Omega; Sahu, Srikant K; Kar, Sarita; Vemuganti, Geeta K
2011-09-01
To correlate the culture results of corneal scrapings with culture and histopathology results of corneal tissues in therapeutic keratoplasty. A retrospective analysis of the culture results of corneal scrapings and corneal tissues of eyes that received therapeutic penetrating keratoplasty at a tertiary eye care center between December 2006 and November 2008 was conducted. As per the preferred practice, those cases that did not respond to appropriate antimicrobial therapy and/or presented with a large infiltrate/perforation received therapeutic keratoplasty. The microbiology and histopathology findings of the corneal tissues were compared. Thirty-eight therapeutic keratoplasties were performed on 36 patients. Although all cases had histopathology and culture of the corneal tissue, corneal scrapings were not performed in 4 cases. Corneal scrapings and corneal tissues were culture-positive in 76% (26 of 34) and 60% (23 of 38) of cases, respectively. In 8 cases, the corneal scrapings and corneal tissues yielded identical organisms, whereas different organisms grew in 4 cases. In 6 cases, the corneal tissues were culture-positive but the corneal scrapings were sterile. In 20 cases, the corneal tissues were culture-positive for fungus and also showed fungal filaments in their corresponding histopathology specimens. Corneal tissue culture can provide additional information in cases undergoing therapeutic keratoplasty. It helps to determine the management of patients after keratoplasty.
The resistance patterns of normal ocular bacterial flora to 4 fluoroquinolone antibiotics.
Park, Shin Hae; Lim, Jeong-A; Choi, Jun-Sub; Kim, Kyung-A; Joo, Choun-Ki
2009-01-01
The purposes of this study were to determine the normal ocular bacterial flora isolated from patients undergoing anterior segment surgery and to evaluate their in vitro susceptibility to ciprofloxacin, levofloxacin, gatifloxacin, and moxifloxacin. During January 2006 to December 2006, conjunctival swabs taken from 385 eyes were inoculated onto 5% blood agar plates. The isolated bacteria were classified by analysis of 16s ribosomal DNA sequencing. Disk diffusion testing was performed in accordance with Clinical and Laboratory Standards Institute Performance Standards. Three hundred sixty-three microorganisms were isolated in 291 samples from 385 eyes. Gram-positive species predominated (89.8%, 326 of the 363 isolates), and Staphylococcus epidermidis was the most frequently isolated organism, accounting for 60.6% (220 of the 363 isolates). For 293 gram-positive isolates, the prevalence rates of in vitro resistance to ciprofloxacin, levofloxacin, gatifloxacin, and moxifloxacin were 22.2% (65 isolates), 11.6% (34), 2.7% (8), and 5.1% (15), respectively. Two of the gram-negative isolates were resistant to only ciprofloxacin (5.4%, 2 of 37 isolates) and not to other fluoroquinolones. Of 62 ciprofloxacin-resistant, coagulase-negative staphylococci, 32 (51.6%) showed coresistance to levofloxacin. Seven organisms were resistant to all the fluoroquinolones. Fluoroquinolones have activity against normal aerobic flora of the ocular surface. Normal ocular flora, especially gram-positive species, has low resistance to the fourth-generation fluoroquinolones -- gatifloxacin and moxifloxacin.
Characterisation of myofibroblasts in fibrovascular tissues of primary and recurrent pterygia
Touhami, A; Di Pascuale, M A; Kawatika, T; Valle, M Del; Rosa, R H; Dubovy, S; Tseng, S C G
2005-01-01
Aims: To determine the presence and origin of myofibroblasts in pterygia. Methods: 86 specimens including head, body, and fibrovascular tissue from 52 primary and 34 recurrent pterygia and five exenterated eyes without pterygia were searched for the origin of myofibroblasts. All tissues were subjected to haematoxylin and eosin staining, immunohistochemistry using antibodies against alpha smooth muscle actin (α-SMA), desmin, vimentin, and caldesmon, and transmission electron microscopy (TEM). The phenotype of fibroblasts subcultured in a serum free medium from pterygium fibrovascular tissues was characterised by the above antibodies. Bundles of dense fibrous tissues were noted in 86% of the fibrovascular tissue specimens evaluated. Cells within these bundles were characterised as myofibroblasts based on positive staining to α-SMA, but negative to desmin and caldesmon, markers for smooth muscle cells. Interestingly, positive α-SMA staining was also found in the periorbital fibroadipose tissue posterior to Tenon’s capsule near the nasal conjunctiva in all exenterated specimens. All first passage fibroblasts expressed vimentin, some were positive to α-SMA, but all were negative to desmin or caldesmon. Cells in pterygium fibrovascular tissues showed ultrastructural features of intracytoplasmic bundles of microfilaments, consistent with myofibroblastic differentiation. Conclusion: These studies collectively demonstrate the presence of contractile myofibroblasts bundle in pterygia and in the periorbital fibroadipose tissue posterior to Tenon’s capsule of exenterated eyes without pterygium. PMID:15722301
Economic inequality in eye care utilization and its determinants: a Blinder–Oaxaca decomposition
Emamian, Mohammad Hassan; Zeraati, Hojjat; Majdzadeh, Reza; Shariati, Mohammad; Hashemi, Hassan; Fotouhi, Akbar
2014-01-01
Background: The current study aimed to determine eye care utilization, to assess the role of economic inequality in the utilization of eye care services, and to identify its determinants in Shahroud, North of Iran. Methods: Of the 6,311 invited people, 5,190 (82.24%) individuals aged 40 to 64 years old participated in the study. A history of a visit by an ophthalmologist or optometrist was considered as eye care utilization. The gap between low- and high-economic groups was decomposed into its determinants using the Oaxaca decomposition method. Results: Among the participants, 16.32% [95% Confidence Intervals (CI)= 15.31–17.33%] had never been examined by an ophthalmologist or optometrist, and 30.94% (95% CI= 29.69–32.20%) had not undergone an eye examination in the past 5 years. This negative history was significantly higher among female subjects [Odds Ratio (OR)= 1.79, 95% CI= 1.51–2.14], the low-economic group (OR= 2.33, 95% CI= 1.90–2.87), the visually impaired (OR= 1.41, 95% CI= 1.05–1.90), and the uninsured (OR= 1.93, 95% CI= 1.45–2.58). The negative history of eye examination decreased with increasing in age (OR= 0.94, 95% CI= 0.93–0.96) and education (OR= 0.94, 95% CI= 0.92–0.96). In this study, 24.72% (95% CI= 22.30–27.14) of the low-economic group and 9.94% (95% CI= 8.75–11.14) of the high-economic group had no history of eye examination. Decomposition of the gap between the two economic groups showed that education and gender were the most important determinants of inequality. Conclusion: A considerable percentage of adults, even those with visual impairment, do not receive appropriate eye care. There is a definite economic inequality in the community for which poverty per se could be the major cause. PMID:25396206
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-17
... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-81,009] Birds Eye Foods, LLC... workers of Birds Eye Foods, LLC, Fulton, NY Plant, a wholly-owned subsidiary of Pinnacle Foods Group LLC... Eye Foods, LLC. The Department has determined that these workers were sufficiently under the control...
Pilot randomised controlled trial of face-down positioning following macular hole surgery.
Lange, C A K; Membrey, L; Ahmad, N; Wickham, L; Maclaren, R E; Solebo, L; Xing, W; Bunce, C; Ezra, E; Charteris, D; Aylward, B; Yorston, D; Gregor, Z; Zambarakji, H; Bainbridge, J W
2012-02-01
This was a pilot randomised controlled trial (RCT) to investigate the effect of post-operative face-down positioning on the outcome of macular hole surgery and to inform the design of a larger definitive study. In all, 30 phakic eyes of 30 subjects with idiopathic full-thickness macular holes underwent vitrectomy with dye-assisted peeling of the ILM and 14% perfluoropropane gas. Subjects were randomly allocated to posture face down for 10 days (posturing group) or to avoid a face-up position only (non-posturing group). The primary outcome was anatomical hole closure. Macular holes closed in 14 of 15 eyes (93.3%; 95% confidence interval (CI) 68-100%) in the posturing group and in 9 of 15 (60%; 95% CI 32-84%) in the non-posturing group. In a subgroup analysis of outcome according to macular hole size, all holes smaller than 400 μm closed regardless of posturing (100%). In contrast, holes larger than 400 μm closed in 10 of 11 eyes (91%; 95% CI 58-99%) in the posturing group and in only 4 of 10 eyes (40%; 95% CI 12-74%) in the non-posturing group (Fisher's exact test P=0.02). Post-operative face-down positioning may improve the likelihood of macular hole closure, particularly for holes larger than 400 μm. These results support the case for a RCT.
[Application of automatic photography in Schistosoma japonicum miracidium hatching experiments].
Ming-Li, Zhou; Ai-Ling, Cai; Xue-Feng, Wang
2016-05-20
To explore the value of automatic photography in the observation of results of Schistosoma japonicum miracidium hatching experiments. Some fresh S. japonicum eggs were added into cow feces, and the samples of feces were divided into a low infested experimental group and a high infested group (40 samples each group). In addition, there was a negative control group with 40 samples of cow feces without S. japonicum eggs. The conventional nylon bag S. japonicum miracidium hatching experiments were performed. The process was observed with the method of flashlight and magnifying glass combined with automatic video (automatic photography method), and, at the same time, with the naked eye observation method. The results were compared. In the low infested group, the miracidium positive detection rates were 57.5% and 85.0% by the naked eye observation method and automatic photography method, respectively ( χ 2 = 11.723, P < 0.05). In the high infested group, the positive detection rates were 97.5% and 100% by the naked eye observation method and automatic photography method, respectively ( χ 2 = 1.253, P > 0.05). In the two infested groups, the average positive detection rates were 77.5% and 92.5% by the naked eye observation method and automatic photography method, respectively ( χ 2 = 6.894, P < 0.05). The automatic photography can effectively improve the positive detection rate in the S. japonicum miracidium hatching experiments.
NASA Astrophysics Data System (ADS)
1985-01-01
A new invention by scientists who have copied the structure of a human eye will help replace a human telescope-watching astronomer with a robot. It will be possible to provide technical vision not only for robot astronomers but also for their industrial fellow robots. So far, an artificial eye with dimensions close to those of a human eye discerns only black-and-white images. But already the second model of the eye is to perceive colors as well. Polymers which are suited for the role of the coat of an eye, lens, and vitreous body were applied. The retina has been replaced with a bundle of the finest glass filaments through which light rays get onto photomultipliers. They can be positioned outside the artificial eye. The main thing is to prevent great losses in the light guide.
Genetic analysis of fibroblast growth factor signaling in the Drosophila eye.
Mukherjee, T; Choi, I; Banerjee, Utpal
2012-01-01
The development of eyes in Drosophila involves intricate epithelial reorganization events for accurate positioning of cells and proper formation and organization of ommatidial clusters. We demonstrate that Branchless (Bnl), the fibroblast growth factor ligand, regulates restructuring events in the eye disc primordium from as early as the emergence of clusters from a morphogenetic front to the cellular movements during pupal eye development. Breathless (Btl) functions as the fibroblast growth factor receptor to mediate Bnl signal, and together they regulate expression of DE-cadherin, Crumbs, and Actin. In addition, in the eye Bnl regulates the temporal onset and extent of retinal basal glial cell migration by activating Btl in the glia. We hypothesized that the Bnl functions in the eye are Hedgehog dependent and represent novel aspects of Bnl signaling not explored previously.
Basnet, Bishal Babu; Parajuli, Prakash Kumar; Singh, Raj Kumar; Suwal, Pramita; Shrestha, Pragya; Baral, Dharanidhar
2015-01-01
Establishment of proper occlusal vertical dimension (OVD) is one of the important tasks for successful prosthodontic therapy. An ideal method for determining OVD in terms of cost, time, and instrument requirements has been sought in prosthodontics by various investigators. However, no such single method has been formulated. In the current anthropometric study, the relationship of the length of the thumb to the OVD was tested in two ethnic groups of Nepal, Aryans, and Mongoloids. The result of this study can be useful in determining proper OVD in edentulous patients. The primary aim of the present study was to evaluate the correlation between the length of the thumb and OVD in Aryan and Mongoloid ethnic groups. The secondary aim was to compare the correlation between OVD and other anatomic measurements (eye-ear distance and pupil-to-rima oris distance) in these ethnicities. The OVD, thumb length, eye-ear distance and distance between pupil of eye and rima oris were measured in a total of 500 adult dentulous volunteers. The correlation between OVD and thumb length as well as other anatomic measurements was checked with Pearson's product moment correlation coefficient. Linear regression analysis was performed to determine the relationship of OVD to the length of the thumb. The thumb length was significantly (P≤0.05) correlated with strong and positive values (Pearson's coefficient =0.874 in the whole population, 0.826 in Aryans, and 0.944 in Mongoloids). Regression analysis showed that thumb length was significantly related to OVD in both ethnic groups. Within the limitations of the present study, the result implies that thumb length can be used as an adjunct for establishing OVD in the edentulous patients.
Kromeier, M; Kommerell, G
2006-01-01
The "Measuring and Correcting Methodology after H.-J. Haase" is based on the assumption that a minute deviation from the orthovergence position (fixation disparity) indicates a difficulty to overcome a larger "vergence angle of rest". Objective recordings have, however, revealed that the subjective tests applied in the "Measuring and Correcting Methodology after H.-J. Haase" can mislead to the assumption of a fixation disparity, although both eyes are aligned exactly to the fixation point. How do patients with an inconspicuously small, yet objectively verified strabismus react to the "Measuring and Correcting Methodology by H.-J. Haase"? Eight patients with a microesotropia between 0.5 and 3 degrees were subjected to the "Measuring and Correcting Methodology after H.-J. Haase. In all 8 patients, the prisms determined with the Cross-, Pointer- and Rectangle Tests increased the angle of squint, without reaching a full correction: the original angle prevailed. In the Stereobalance Test, prisms did not reduce the 100 % preponderance of the non-squinting eye. The stereoscopic threshold was between 36 and 1170 arcsec in 7 out of the 8 subjects, and above 4000 arcsec in 1 subject. (1) In all 8 patients, prisms determined with the "Measuring and Correcting Methodology by H.-J. Haase" increased the angle of strabismus, without reaching bifoveal vision. This uniform result suggests that primary microesotropia cannot be corrected with the "Measuring and Correcting Methodology after H.-J. Haase" (2) A lacking contribution of the strabismic eye to the recognition of a lateral offset between stereo objects, as determined with the Stereobalance Test, does not imply a lack of binocular stereopsis.
Enhanced iris recognition method based on multi-unit iris images
NASA Astrophysics Data System (ADS)
Shin, Kwang Yong; Kim, Yeong Gon; Park, Kang Ryoung
2013-04-01
For the purpose of biometric person identification, iris recognition uses the unique characteristics of the patterns of the iris; that is, the eye region between the pupil and the sclera. When obtaining an iris image, the iris's image is frequently rotated because of the user's head roll toward the left or right shoulder. As the rotation of the iris image leads to circular shifting of the iris features, the accuracy of iris recognition is degraded. To solve this problem, conventional iris recognition methods use shifting of the iris feature codes to perform the matching. However, this increases the computational complexity and level of false acceptance error. To solve these problems, we propose a novel iris recognition method based on multi-unit iris images. Our method is novel in the following five ways compared with previous methods. First, to detect both eyes, we use Adaboost and a rapid eye detector (RED) based on the iris shape feature and integral imaging. Both eyes are detected using RED in the approximate candidate region that consists of the binocular region, which is determined by the Adaboost detector. Second, we classify the detected eyes into the left and right eyes, because the iris patterns in the left and right eyes in the same person are different, and they are therefore considered as different classes. We can improve the accuracy of iris recognition using this pre-classification of the left and right eyes. Third, by measuring the angle of head roll using the two center positions of the left and right pupils, detected by two circular edge detectors, we obtain the information of the iris rotation angle. Fourth, in order to reduce the error and processing time of iris recognition, adaptive bit-shifting based on the measured iris rotation angle is used in feature matching. Fifth, the recognition accuracy is enhanced by the score fusion of the left and right irises. Experimental results on the iris open database of low-resolution images showed that the averaged equal error rate of iris recognition using the proposed method was 4.3006%, which is lower than that of other methods.
Bilateral retinitis following Chikun- gunya fever
Murthy, Krishna R; Venkataraman, Nandita; Satish, Vidya
2008-01-01
A 35-year-old male with a history of chikungunya fever, presented with diminution of vision in the right eye of one-week duration. His best corrected visual acuity (BCVA) was counting fingers 2 meters and 20/20 (Snellens) in the right and left eyes respectively. A diagnosis of neuroretinitis was made in the right eye while left eye showed features of retinitis. ELISA (serum) and polymerase chain reaction (aqueous) were positive for herpes simplex virus. The lesions did not show any response to antiviral or steroid treatment and appeared to be self-limiting. At five months follow-up, lesions had resolved well with BCVA of 20/120 and 20/20 in the right and left eyes respectively. PMID:18579997
Dietze, Holger H; Cox, Michael J
2003-02-01
Soft contact lenses produce a significant level of spherical aberration affecting their power on-eye. A simple model assuming that a thin soft contact lens aligns to the cornea predicts that these effects are similar on-eye and off-eye. The wavefront aberration for 17 eyes and 33 soft contact lenses on-eye was measured with a Shack-Hartmann wavefront sensor. The Zernike coefficients describing the on-eye spherical aberration of the soft contact lens were compared with off-eye ray-tracing results. Paraxial and effective lens power changes were determined. The model predicts the on-eye spherical aberration of soft contact lenses closely. The resulting power change for a +/- 7.00 D spherical soft contact lens is +/- 0.5 D for a 6-mm pupil diameter and +/- 0.1 D for a 3-mm pupil diameter. Power change is negligible for soft contact lenses corrected for off-eye spherical aberration. For thin soft contact lenses, the level of spherical aberration and the consequent power change is similar on-eye and off-eye. Soft contact lenses corrected for spherical aberration in air will be expected to be aberration-free on-eye and produce only negligibly small power changes. For soft contact lenses without aberration correction, for higher levels of ametropia and large pupils, the soft contact lens power should be determined with trial lenses with their power and p value similar to the prescribed lens. The benefit of soft contact lenses corrected for spherical aberration depends on the level of ocular spherical aberration.
Centripetal force draws the eyes, not memory of the target, toward the center.
Kerzel, Dirk
2003-05-01
Many observers believe that a target will continue on a curved trajectory after exiting a spiral tube. Similarly, when observers were asked to localize the final position of a target moving on a circular orbit, displacement of the judged position in the direction of forward motion ("representational momentum") and toward the center of the orbit was observed (cf. T. L. Hubbard, 1996). The present study shows that memory displacement of targets on a circular orbit is affected by eye movements. Forward displacement was larger with ocular pursuit of the target, whereas inward displacement was larger with motionless eyes. The results challenge an account attributing forward and inward displacement to mental analogues of momentum and centripetal force, respectively.