Teper, Sławomir J.; Janiszewska, Dominika A.; Lyssek-Boron, Anita; Dobrowolski, Dariusz; Koprowski, Robert; Wylegala, Edward
2015-01-01
Purpose. To compare anterior eye segment measurements and morphology obtained with two optical coherence tomography systems (TD OCT, SS OCT) in eyes with corneal dystrophies (CDs). Methods. Fifty healthy volunteers (50 eyes) and 54 patients (96 eyes) diagnosed with CD (epithelial basement membrane dystrophy, EBMD = 12 eyes; Thiel-Behnke CD = 6 eyes; lattice CD TGFBI type = 15 eyes; granular CD type 1 = 7 eyes, granular CD type 2 = 2 eyes; macular CD = 23 eyes; and Fuchs endothelial CD = 31 eyes) were recruited for the study. Automated and manual central corneal thickness (aCCT, mCCT), anterior chamber depth (ACD), and nasal and temporal trabecular iris angle (nTIA, tTIA) were measured and compared with Bland-Altman plots. Results. Good agreement between the TD and SS OCT measurements was demonstrated for mCCT and aCCT in normal individuals and for mCCT in the CDs group. The ACD, nTIA, and tTIA measurements differed significantly in both groups. TBCD, LCD, and FECD caused increased CCT. MCD caused significant corneal thinning. FECD affected all analyzed parameters. Conclusions. Better agreement between SS OCT and TD OCT measurements was demonstrated in normal individuals compared to the CDs group. OCT provides comprehensive corneal deposits analysis and demonstrates the association of CD with CCT, ACD, and TIA measurements. PMID:26457303
Nowinska, Anna K; Teper, Sławomir J; Janiszewska, Dominika A; Lyssek-Boron, Anita; Dobrowolski, Dariusz; Koprowski, Robert; Wylegala, Edward
2015-01-01
To compare anterior eye segment measurements and morphology obtained with two optical coherence tomography systems (TD OCT, SS OCT) in eyes with corneal dystrophies (CDs). Fifty healthy volunteers (50 eyes) and 54 patients (96 eyes) diagnosed with CD (epithelial basement membrane dystrophy, EBMD = 12 eyes; Thiel-Behnke CD = 6 eyes; lattice CD TGFBI type = 15 eyes; granular CD type 1 = 7 eyes, granular CD type 2 = 2 eyes; macular CD = 23 eyes; and Fuchs endothelial CD = 31 eyes) were recruited for the study. Automated and manual central corneal thickness (aCCT, mCCT), anterior chamber depth (ACD), and nasal and temporal trabecular iris angle (nTIA, tTIA) were measured and compared with Bland-Altman plots. Good agreement between the TD and SS OCT measurements was demonstrated for mCCT and aCCT in normal individuals and for mCCT in the CDs group. The ACD, nTIA, and tTIA measurements differed significantly in both groups. TBCD, LCD, and FECD caused increased CCT. MCD caused significant corneal thinning. FECD affected all analyzed parameters. Better agreement between SS OCT and TD OCT measurements was demonstrated in normal individuals compared to the CDs group. OCT provides comprehensive corneal deposits analysis and demonstrates the association of CD with CCT, ACD, and TIA measurements.
Effect of eye rubbing on signs and symptoms of allergic conjunctivitis in cat-sensitive individuals.
Raizman, M B; Rothman, J S; Maroun, F; Rand, W M
2000-12-01
To evaluate the effect of eye rubbing on signs and symptoms of allergic conjunctivitis in cat-sensitive individuals. Two prospective, nonrandomized comparative studies. Thirteen patients in the first study and 20 patients in the second study with a documented history of acute allergic conjunctivitis induced by exposure to cats were enrolled. In the first trial, all patients had one eye rubbed 15 times by the investigator without exposure to airborne allergens. Both eyes were evaluated after 5, 15, 30, and 60 minutes using subject questionnaires and slit-lamp examination. At least 1 week later, each patient was exposed to cat dander for 75 minutes; 15 minutes after entering the cat room, each patient had one eye rubbed 15 times by the examiner. Subjects' eyes were then evaluated using questionnaires and slit-lamp examination. In the second trial, the visits were identical to the first trial, except that the rubbed eye in each visit was rubbed 20 times and with more force, and that patients wore masks during exposure to cat dander. In both studies, the difference between patients' rubbed and nonrubbed eyes with respect to ocular itching, chemosis, and hyperemia was noted 5, 15, 30, and 60 minutes after controlled eye rubbing. Without exposure to the cat room, rubbed eyes exhibited increased itching at 5 minutes in both studies and at 15 minutes in the second study (P < 0.05), increased chemosis at 5 and 15 minutes in the second study (P < 0.05), and increased hyperemia at 5 minutes in the second study (P < 0.05) compared with nonrubbed eyes. During exposure to cat dander, rubbed eyes consistently exhibited increased itching at 5, 15, and 30 minutes in the first and second study as well as at 60 minutes in the second study compared with nonrubbed eyes. Furthermore, during exposure to cat dander, rubbed eyes consistently exhibited increased chemosis at 5 and 15 minutes (P < 0.05) and increased hyperemia at 5, 15, and 30 minutes (P < 0.05) in the second study compared with nonrubbed eyes. Firm eye rubbing causes a mild and transient increase in ocular itching, chemosis, and hyperemia. However, after exposure to cat allergens in cat-sensitive individuals, the effects of eye rubbing are longer and more dramatic. Eye rubbing may play a role in ocular signs and symptoms of allergic conjunctivitis in cat-sensitive individuals, especially after exposure to cat dander.
Herbst, Kristina; Sander, Birgit; Lund-Andersen, Henrik; Wegener, Marianne; Hannibal, Jens; Milea, Dan
2013-01-01
The intrinsically photosensitive retinal ganglion cells (ipRGCs) express the photopigment melanopsin, which is sensitive to blue light. Previous chromatic pupillometry studies have shown that the post-illumination response is considered an indicator of the melanopsin activation. The aim of this study was to investigate the ipRGC mediated pupil response in patients with a unilateral non-arteritic anterior ischemic optic neuropathy (NAION). Consensual pupil responses during and after exposure to continuous 20 s blue (470 nm) or red (660 nm) light of high intensity (300 cd/m2) were recorded in each eye for 10 patients. Comparisons were performed both intra-individually (affected versus non-affected eyes) and inter-individually (compared with healthy controls). The pupil response was calculated both during the illumination and during the post-illumination phase. The pupil responses to blue and red colors were significantly reduced in the NAION-affected eyes, compared with the fellow non-affected eyes. When comparing the affected eyes with the healthy control eyes, the post-illumination responses were not significantly different. In addition, the post-illumination pupil responses after blue light exposure were increased in the fellow non-affected patients’ eyes, compared with the healthy controls. However, significance was only reached for the late post-illumination response. In conclusion, chromatic pupillometry disclosed reduced post-illumination pupil responses in the NAION-affected eyes, compared with the non-affected fellow eyes, suggesting dysfunction of the ipRGCs. Compared with the responses of the healthy controls, the blue light post-illumination pupil responses were similar in the affected eyes and increased in the fellow non-affected eyes. This suggests a possible adaptive phenomenon, involving the ipRGCs of both eyes after unilateral NAION. PMID:23717301
Peripapillary Pachychoroid in Nonarteritic Anterior Ischemic Optic Neuropathy
Nagia, Lina; Huisingh, Carrie; Johnstone, John; Kline, Lanning B.; Clark, Mark; Girard, Michael J. A.; Mari, Jean Martial; Girkin, Christopher A.
2016-01-01
Purpose This study examined the peripapillary choroidal thickness (PCT) in nonarteritic ischemic optic neuropathy (NAION) in comparison to contralateral eyes and normal eyes. Methods We used enhanced depth imaging spectral-domain optical coherence tomography to image the optic nerve head of 20 NAION, 10 contralateral eyes, and 102 normal eyes. Following compensation, the scans were manually delineated to identify relevant surfaces including Bruch's membrane opening (BMO), Bruch's membrane, and anterior sclera. The PCT was defined as the measurement between Bruch's membrane and the anterior sclera and was measured at increasing distance from BMO. Models adjusted for age, BMO area, and axial length were used to compare the mean PCT between NAION and normal eyes, and contralateral eyes and normal eyes. Paired t-tests were used to compare the PCT between NAION and contralateral eyes. Results The mean PCT was thicker in NAION and contralateral eyes when compared with normal eyes at all distances from BMO (P < 0.001). The PCT was not significantly thicker in contralateral eyes when compared with affected NAION eyes. Choroidal thickness was thinnest in the inferior quadrant in all eyes regardless of the group. Conclusions Increased peripapillary choroidal thickness was noted in both NAION and contralateral eyes. The thicker choroid may be an associated feature or a result of the disorder. Although further longitudinal study is required to determine causation, these findings may suggest that a thickened peripapillary choroid may be a component of the disk-at-risk clinical phenotype. PMID:27583829
Comparing Interrater reliability between eye examination and eye self-examination 1
de Lima, Maria Alzete; Pagliuca, Lorita Marlena Freitag; do Nascimento, Jennara Cândido; Caetano, Joselany Áfio
2017-01-01
Resume Objective: to compare Interrater reliability concerning two eye assessment methods. Method: quasi-experimental study conducted with 324 college students including eye self-examination and eye assessment performed by the researchers in a public university. Kappa coefficient was used to verify agreement. Results: reliability coefficients between Interraters ranged from 0.85 to 0.95, with statistical significance at 0.05. The exams to check for near acuity and peripheral vision presented a reasonable kappa >0.2. The remaining coefficients were higher, ranging from very to totally reliable. Conclusion: comparatively, the results of both methods were similar. The virtual manual on eye self-examination can be used to screen for eye conditions. PMID:29069269
Iglicki, Matias; Busch, Catharina; Zur, Dinah; Okada, Mali; Mariussi, Miriana; Chhablani, Jay Kumar; Cebeci, Zafer; Fraser-Bell, Samantha; Chaikitmongkol, Voraporn; Couturier, Aude; Giancipoli, Ermete; Lupidi, Marco; Rodríguez-Valdés, Patricio J; Rehak, Matus; Fung, Adrian Tien-Chin; Goldstein, Michaella; Loewenstein, Anat
2018-04-24
To investigate efficacy and safety of repeated dexamethasone (DEX) implants over 24 months, in diabetic macular edema (DME) eyes that were treatment naive compared with eyes refractory to anti-vascular endothelial growth factor treatment, in a real-life environment. This multicenter international retrospective study assessed best-corrected visual acuity and central subfield thickness (CST) of naive and refractory eyes to anti-vascular endothelial growth factor injections treated with dexamethasone implants. Safety data (intraocular pressure rise and cataract surgery) were recorded. A total of 130 eyes from 125 patients were included. Baseline best-corrected visual acuity and CST were similar for naive (n = 71) and refractory eyes (n = 59). Both groups improved significantly in vision after 24 months (P < 0.001). However, naive eyes gained statistically significantly more vision than refractory eyes (+11.3 ± 10.0 vs. 7.3 ± 2.7 letters, P = 0.01) and were more likely to gain ≥10 letters (OR 3.31, 95% CI 1.19-9.24, P = 0.02). At 6, 12, and 24 months, CST was significantly decreased compared with baseline in both naive and refractory eyes; however, CST was higher in refractory eyes than in naive eyes (CST 279 ± 61 vs. 313 ± 125 μm, P = 0.10). Over a follow-up of 24 months, vision improved in diabetic macular edema eyes after treatment with dexamethasone implants, both in eyes that were treatment naive and eyes refractory to anti-vascular endothelial growth factor treatment; however, improvement was greater in naive eyes.
Ogura, Atsushi; Ikeo, Kazuho; Gojobori, Takashi
2004-01-01
Although the camera eye of the octopus is very similar to that of humans, phylogenetic and embryological analyses have suggested that their camera eyes have been acquired independently. It has been known as a typical example of convergent evolution. To study the molecular basis of convergent evolution of camera eyes, we conducted a comparative analysis of gene expression in octopus and human camera eyes. We sequenced 16,432 ESTs of the octopus eye, leading to 1052 nonredundant genes that have matches in the protein database. Comparing these 1052 genes with 13,303 already-known ESTs of the human eye, 729 (69.3%) genes were commonly expressed between the human and octopus eyes. On the contrary, when we compared octopus eye ESTs with human connective tissue ESTs, the expression similarity was quite low. To trace the evolutionary changes that are potentially responsible for camera eye formation, we also compared octopus-eye ESTs with the completed genome sequences of other organisms. We found that 1019 out of the 1052 genes had already existed at the common ancestor of bilateria, and 875 genes were conserved between humans and octopuses. It suggests that a larger number of conserved genes and their similar gene expression may be responsible for the convergent evolution of the camera eye. PMID:15289475
Goldenberg, David T.; Giblin, Frank J.; Cheng, Mei; Chintala, Shravan K.; Trese, Michael T.; Drenser, Kimberly A.; Ruby, Alan J.
2010-01-01
Purpose Intravitreal bevacizumab (Avastin) is frequently used for the treatment of age-related macular degeneration. Previous studies have demonstrated full thickness retinal penetration. Intravitreal recombinant microplasmin (MP) has been shown to successfully induce a posterior vitreous detachment (PVD) and vitreous liquefaction in animals. It has been suggested that a PVD may alter the retinal penetration of molecules in the vitreous cavity. The aim of this study was to compare bevacizumab (BV) retinal penetration in rabbit eyes with and without a MP-induced PVD. Methods Twelve adult rabbits were injected with 0.1 ml (0.4 mg) of MP into the vitreous cavity of one eye. One week later, the rabbits were injected with 0.05 ml (1.25 mg) of BV into both eyes. Both eyes of three rabbits each were harvested at 6, 12, 24, and 72 hours after the BV injection. Frozen retinal cross sections were prepared, and BV retinal penetration was evaluated with immunohistochemistry using a fluorescence-labeled antibody against BV. Two eyes from one rabbit were not injected with either agent and used as controls to compare the background autofluorescence. Peripapillary retinal sections were recorded with a digital camera, and intra-retinal BV fluorescence-labeled antibody was measured by qualitative photographic interpretation. Two additional rabbits received an intravitreal injection of 0.1 ml of MP in one eye. One week later, both eyes from each rabbit were enucleated and frozen retinal sections were prepared and analyzed with light microscopy to evaluate for histologic damage. Results Full thickness BV retinal penetration was observed throughout the retina in both eyes of each rabbit. All of the MP-injected eyes exhibited increased antibody labeling in retinas evaluated 6, 12, and 24 hours after BV injection when compared with the contralateral non-MP-injected eyes. By three days after BV injection, all eyes demonstrated decreased antibody labeling compared to earlier time periods. At three days, one rabbit showed increased antibody labeling in the retina of the non-MP-injected eye compared with the contralateral MP-injected eye, and two rabbits exhibited similar antibody labeling in both eyes. When compared with control eyes, light microscopy demonstrated normal retinal histologic findings in eyes injected only with microplasmin. Conclusions Increased BV retinal penetration is observed initially in eyes with a MP-induced PVD, and the mechanism is likely multifactorial. By three days, retinal penetration is similar in eyes with and without a PVD. Although it is difficult to directly extrapolate to humans, our study suggests a PVD may alter the retinal penetration of BV. PMID:21099453
Plasma Rich in Growth Factors for the Treatment of Dry Eye after LASIK Surgery.
Sanchez-Avila, Ronald Mauricio; Merayo-Lloves, Jesus; Fernandez, Maria Laura; Rodriguez-Gutierrez, Luis Alberto; Jurado, Nancy; Muruzabal, Francisco; Orive, Gorka; Anitua, Eduardo
2018-06-08
The aim of this study was to evaluate the use of plasma rich in growth factors (PRGF) eye drops in patients with dry eye disease after laser-assisted in situ keratomileusis (LASIK) surgery. This is a longitudinal, retrospective, comparative, and descriptive study of 77 eyes of 42 patients with dry eye disease following LASIK surgery. This study was designed to evaluate the efficacy of PRGF treatment compared to conventional therapy (control group). Outcome measures including signs and symptoms of dry eye disease were evaluated before and after treatment. The percentage of change before and after treatment for each clinical variable measured was compared between both groups. There were 1-4 treatment cycles with PRGF eye drops (1 cycle = 6 weeks). Results showed a statistically significant improvement in the Ocular Surface Disease Index (38.12%), visual analogue scale scores for frequency (41.89%) and severity (42.47%), and the Schirmer test scores (88.98%) after PRGF treatment (p < 0.05). No adverse events were reported after PRGF treatment. These results suggest that PRGF eye drops are effective for the improvement of dry eye symptoms in patients who underwent LASIK surgery in comparison to the conventional therapy. The treatment with PRGF is an alternative for patients who suffer from postoperative dry eye. © 2018 S. Karger AG, Basel.
Yazdani, Shahin; Mahboobipour, Hassan; Pakravan, Mohammad; Doozandeh, Azadeh; Ghahari, Elham
2016-05-01
To determine whether adjunctive mitomycin C (MMC) or amniotic membrane transplantation (AMT) improve the outcomes of Ahmed glaucoma valve (AGV) implantation. This double-blind, stratified, 3-armed randomized clinical trial includes 75 eyes of 75 patients aged 7 to 75 years with refractory glaucoma. Eligible subjects underwent stratified block randomization; eyes were first stratified to surgery in the superior or inferior quadrants based on feasibility; in each subgroup, eyes were randomly assigned to the study arms using random blocks: conventional AGV implantation (group A, 25 eyes), AGV with MMC (group B, 25 eyes), and AGV with AMT (group C, 25 eyes). The 3 study groups were comparable regarding baseline characteristics and mean follow-up (P=0.288). A total of 68 patients including 23 eyes in group A, 25 eyes in group B, and 20 eyes group C completed the follow-up period and were analyzed. Intraocular pressure was lower in the MMC group only 3 weeks postoperatively (P=0.04) but comparable at other time intervals. Overall success rate was comparable in the 3 groups at 12 months (P=0.217). The number of eyes requiring medications (P=0.30), time to initiation of medications (P=0.13), and number of medications (P=0.22) were comparable. Hypertensive phase was slightly but insignificantly more common with standard surgery (82%) as compared with MMC-augmented (60%) and AMT-augmented (70%) procedures (P=0.23). Complications were comparable over 1 year (P=0.28). Although adjunctive MMC and AMT were safe during AGV implantation, they did not influence success rates or intraocular pressure outcomes. Complications, including hypertensive phase, were also comparable.
Intrastromal Delivery of Bevacizumab Using Microneedles to Treat Corneal Neovascularization
Kim, Yoo C.; Grossniklaus, Hans E.; Edelhauser, Henry F.; Prausnitz, Mark R.
2014-01-01
Purpose. This study tested the hypothesis that highly targeted intrastromal delivery of bevacizumab using coated microneedles allows dramatic dose sparing compared with subconjunctival and topical delivery for treatment of corneal neovascularization. Methods. Stainless steel microneedles 400 μm in length were coated with bevacizumab. A silk suture was placed in the cornea approximately 1 mm from the limbus to induce corneal neovascularization in the eyes of New Zealand white rabbits that were divided into different groups: untreated, microneedle delivery, topical eye drop, and subconjunctival injection of bevacizumab. All drug treatments were initiated 4 days after suture placement and area of neovascularization was measured daily by digital photography for 18 days. Results. Eyes treated once with 4.4 μg bevacizumab using microneedles reduced neovascularization compared with untreated eyes by 44% (day 18). Eyes treated once with 2500 μg bevacizumab using subconjunctival injection gave similar results to microneedle-treated eyes. Eyes treated once with 4.4 μg subconjunctival bevacizumab showed no significant effect compared with untreated eyes. Eyes treated with 52,500 μg bevacizumab by eye drops three times per day for 14 days reduced the neovascularization area compared with untreated eyes by 6% (day 18), which was significantly less effective than the single microneedle treatment. Visual exam and histological analysis showed no observable effect of microneedle treatment on corneal transparency or microanatomical structure. Conclusions. This study shows that microneedles can target drug delivery to corneal stroma in a minimally invasive way and demonstrates effective suppression of corneal neovascularization after suture-induced injury using a much lower dose compared with conventional methods. PMID:25212779
Lim, Jennifer I; Cao, Dingcai
2018-03-17
To determine whether the retina is thinner in sickle cell patients than in race- and age-matched controls, and, if it is thinner, whether there is any association with systemic diseases. Sickle cell and control (age- and race-matched) patients were prospectively enrolled from a university retina clinic into this observational study. Participants underwent visual acuity testing, slit-lamp biomicroscopy, dilated ophthalmoscopy, and spectral-domain optical coherence tomography imaging. Sickle cell retinal lesions, degree of vascular tortuosity, caliber of arteriovenous anastomosis, and stage of retinopathy were noted. Early Treatment Diabetic Retinopathy Study (ETDRS) subfield measurements were compared between sickle cell and control subjects and also among sickle cell hemoglobin subtypes. Associations between ETDRS subfield measurements and hemoglobin subtype, retinopathy stage, and systemic diseases were assessed. A total of 513 sickle cell eyes (260 patients) and 75 control eyes (39 patients) had median visual acuities of 20/20. ETDRS central (P = .002), inner (nasal P = .009, superior P = .021, temporal P < .001, inferior P = .017), and temporal outer (P = .012) subfield measurements were thinner in sickle cell eyes compared to control eyes. Hemoglobin SS eyes had significantly thinner inner ETDRS subfield measurements compared to SC and SThal eyes. Retinal thinning in all subfields was associated with age (P = .017) for sickle cell and control eyes. No association was found between retinal thinning and hydroxyurea use or arteriovenous anastomosis caliber. The macula is thinner in sickle cell eyes compared to control eyes; retinal thickness decreases with increasing age and sickle cell retinopathy stage and is most severe in hemoglobin SS subtypes. Copyright © 2018 Elsevier Inc. All rights reserved.
Retinal layer segmentation in multiple sclerosis: a systematic review and meta-analysis.
Petzold, Axel; Balcer, Laura J; Calabresi, Peter A; Costello, Fiona; Frohman, Teresa C; Frohman, Elliot M; Martinez-Lapiscina, Elena H; Green, Ari J; Kardon, Randy; Outteryck, Olivier; Paul, Friedemann; Schippling, Sven; Vermersch, Patrik; Villoslada, Pablo; Balk, Lisanne J
2017-10-01
Structural retinal imaging biomarkers are important for early recognition and monitoring of inflammation and neurodegeneration in multiple sclerosis. With the introduction of spectral domain optical coherence tomography (SD-OCT), supervised automated segmentation of individual retinal layers is possible. We aimed to investigate which retinal layers show atrophy associated with neurodegeneration in multiple sclerosis when measured with SD-OCT. In this systematic review and meta-analysis, we searched for studies in which SD-OCT was used to look at the retina in people with multiple sclerosis with or without optic neuritis in PubMed, Web of Science, and Google Scholar between Nov 22, 1991, and April 19, 2016. Data were taken from cross-sectional cohorts and from one timepoint from longitudinal studies (at least 3 months after onset in studies of optic neuritis). We classified data on eyes into healthy controls, multiple-sclerosis-associated optic neuritis (MSON), and multiple sclerosis without optic neuritis (MSNON). We assessed thickness of the retinal layers and we rated individual layer segmentation performance by random effects meta-analysis for MSON eyes versus control eyes, MSNON eyes versus control eyes, and MSNON eyes versus MSON eyes. We excluded relevant sources of bias by funnel plots. Of 25 497 records identified, 110 articles were eligible and 40 reported data (in total 5776 eyes from patients with multiple sclerosis [1667 MSON eyes and 4109 MSNON eyes] and 1697 eyes from healthy controls) that met published OCT quality control criteria and were suitable for meta-analysis. Compared with control eyes, the peripapillary retinal nerve fibre layer (RNFL) showed thinning in MSON eyes (mean difference -20·10 μm, 95% CI -22·76 to -17·44; p<0·0001) and in MSNON eyes (-7·41 μm, -8·98 to -5·83; p<0·0001). The macula showed RNFL thinning of -6·18 μm (-8·07 to -4·28; p<0·0001) in MSON eyes and -2·15 μm (-3·15 to -1·15; p<0·0001) in MSNON eyes compared with control eyes. Atrophy of the macular ganglion cell layer and inner plexiform layer (GCIPL) was -16·42 μm (-19·23 to -13·60; p<0·0001) for MSON eyes and -6·31 μm (-7·75 to -4·87; p<0·0001) for MSNON eyes compared with control eyes. A small degree of inner nuclear layer (INL) thickening occurred in MSON eyes compared with control eyes (0·77 μm, 0·25 to 1·28; p=0·003). We found no statistical difference in the thickness of the combined outer nuclear layer and outer plexiform layer when we compared MSNON or MSON eyes with control eyes, but we found a small degree of thickening of the combined layer when we compared MSON eyes with MSNON eyes (1·21 μm, 0·24 to 2·19; p=0·01). The largest and most robust differences between the eyes of people with multiple sclerosis and control eyes were found in the peripapillary RNFL and macular GCIPL. Inflammatory disease activity might be captured by the INL. Because of the consistency, robustness, and large effect size, we recommend inclusion of the peripapillary RNFL and macular GCIPL for diagnosis, monitoring, and research. None. Copyright © 2017 Elsevier Ltd. All rights reserved.
Central Connections of the Lacrimal Functional Unit.
Willshire, Catherine; Buckley, Roger J; Bron, Anthony J
2017-08-01
To study the contribution of each eye to the reflex tear response, after unilateral and bilateral topical anesthesia. A closed-eye, modified Schirmer test was performed bilaterally in 8 normal subjects, in a controlled environment chamber set to 23°C, 45% relative humidity, and 0.08 m/s airflow. Eye drops were instilled into each eye 10 minutes before the Schirmer test. Experiments were as follows: 1) bilateral saline (control), 2) unilateral anesthesia (ipsilateral anesthetic; contralateral saline), and 3) bilateral anesthesia. There was no difference in between-eye wetting lengths in the saline control eyes (P = 0.394) or the bilaterally anesthetized eyes (P = 0.171). The wetting length was reduced in both eyes after bilateral anesthesia compared with saline controls (P = 0.001; P ≤ 0.0005). After unilateral anesthesia, the wetting length was reduced in the anesthetized eye compared with its saline control by 51.4% (P ≤ 0.0005) and compared with its fellow, unanesthetized eye (P = 0.005). The fellow eye value was also reduced compared with its saline control (P = 0.06). The wetting length was reduced by topical anesthesia, when instilled bilaterally and ipsilaterally. The latter response implies an ipsilateral, reflex sensory drive to lacrimal secretion. In the unanesthetized fellow eye, the reduction compared with its saline control was not quite significant. This implies a relative lack of central, sensory, reflex cross-innervation, although the possibility cannot entirely be ruled out. These results are relevant to the possibility of reflex lacrimal compensation from a normal fellow eye, in cases of unilateral corneal anesthesia.
Alcohol versus brush PRK: visual outcomes and adverse effects.
Sia, Rose K; Ryan, Denise S; Stutzman, Richard D; Psolka, Maximilian; Mines, Michael J; Wagner, Melvin E; Weber, Eric D; Wroblewski, Keith J; Bower, Kraig S
2012-08-01
A smooth corneal surface prior to laser ablation is important in order to achieve a favorable refractive outcome. In this study, we compare PRK outcomes following two commonly used methods of epithelial debridement: Amoils epithelial scrubber (brush) versus 20% ethanol (alcohol). We reviewed records of patients who underwent wavefront-optimized PRK for myopia or myopic astigmatism between January 2008 and June 2010. Two treatment groups (brush vs. alcohol) were compared in terms of uncorrected distance visual acuity (UDVA), manifest refraction spherical equivalent (MRSE), corrected distance visual acuity (CDVA), and complications at postoperative months 1, 3, 6, and 12. One thousand five hundred ninety-three eyes of 804 patients underwent PRK during the study period: 828 brush-treated eyes and 765 alcohol-treated eyes. At 6 months postoperatively UDVA was ≥20/20 in 94.7% of brush-treated eyes versus 94.4% of alcohol-treated eyes (P = 0.907). At 1 month a higher percentage of brush-treated eyes maintained or gained one or more lines CDVA compared to alcohol-treated eyes (P = 0.007), but there were no other differences in UDVA, MRSE, or CDVA at any point postoperatively. At 1 month 75.4% of brush-treated eyes versus 70.4% of alcohol-treated eyes were free of complications (P = 0.032), and there were fewer brush-treated eyes with corneal haze (4.0% vs. 6.9%, P = 0.012) and dry eye (8.9% vs. 14.4%, P = 0.001). Although corneal haze was slightly more frequent in the alcohol group, most was trace and not significant. Although alcohol-assisted PRK had more minor complications in the early postoperative period, including corneal haze and dry eye, results for both groups beyond 1 month were comparable. Copyright © 2012 Wiley Periodicals, Inc.
Choroidal thickness in Chinese patients with non-arteritic anterior ischemic optic neuropathy.
Jiang, Libin; Chen, Lanlan; Qiu, Xiujuan; Jiang, Ran; Wang, Yaxing; Xu, Liang; Lai, Timothy Y Y
2016-08-31
Non-arteritic anterior ischemic optic neuropathy (NA-AION) is one of the most common types of ischemic optic neuropathy. Several recent studies suggested that abnormalities of choroidal thickness might be associated with NA-AION. The main objective of this case-control study was to evaluate whether choroidal thickness is an ocular risk factor for the development of NA-AION by evaluating the peripapillary and subfoveal choroidal thicknesses in affected Chinese patients. Forty-four Chinese patients with unilateral NA-AION were recruited and compared with 60 eyes of 60 normal age and refractive-error matched control subjects. Peripapillary and subfoveal choroidal thicknesses were measured by enhanced depth imaging optical coherence tomography. Choroidal thicknesses of eyes with NA-AION and unaffected fellow eyes were compared with normal controls. Choroidal thicknesses of NA-AION eyes with or without optic disc edema were also compared. The correlation between choroidal thickness and retinal nerve fiber layer (RNFL) thickness, logMAR best-corrected visual acuity (BCVA), and the mean deviation (MD) of Humphrey static perimetry in NA-AION eyes were analyzed. The peripapillary choroidal thicknesses at the nasal, nasal inferior and temporal inferior segments in NA-AION eyes with optic disc edema were significantly thicker compared with that of normal subjects (P < 0.05). There was no significant difference in the choroidal thicknesses between the unaffected fellow eyes of NA-AION patients and normal eyes of healthy controls; or between the NA-AION eyes with resolved optic disc edema and normal eyes (all P > 0.05). No significant correlation between choroidal thickness and RNFL thickness, logMAR BCVA and perimetry MD was found in eyes affected by NA-AION (all P > 0.05). Increase in peripapillary choroid thickness in some segments was found in NA-ION eyes with optic disc edema. However, our findings do not support the hypothesis that choroidal thickness is abnormal in Chinese patients with NA-AION compared with normal subjects with similar age and refractive error status.
Rebolleda, Gema; Pérez-Sarriegui, Ane; Díez-Álvarez, Laura; De Juan, Victoria; Muñoz-Negrete, Francisco J
2018-06-01
To compare the optic nerve head morphology among primary open-angle glaucoma, non-arteritic anterior ischemic optic neuropathy eyes, their fellow healthy eyes and control eyes, using spectral-domain optical coherence tomography with enhanced depth imaging. Observational cross-sectional study including 88 eyes of 68 patients. In this study, 23 non-arteritic anterior ischemic optic neuropathy eyes, 17 fellow unaffected eyes, 25 primary open-angle glaucoma eyes, and 23 age-matched control eyes were included. Peripapillary retinal nerve fiber layer thickness and optic disk area were evaluated. Bruch's membrane opening diameter, optic cup depth, anterior lamina cribrosa depth, and prelaminar tissue thickness were assessed. Non-arteritic anterior ischemic optic neuropathy and primary open-angle glaucoma eyes had similar visual field mean deviation and peripapillary retinal nerve fiber layer thickness (P = 0.6 and P = 0.56, respectively). Bruch's membrane opening diameter was significantly larger in primary open-angle glaucoma eyes than in control eyes (P = 0.02). Lamina cribrosa and disk cup were deeper in eyes with primary open-angle glaucoma than both control and non-arteritic anterior ischemic optic neuropathy eyes (P < 0.001). Prelaminar tissue thickness was significantly thinner in primary open-angle glaucoma eyes than in non-arteritic anterior ischemic optic neuropathy eyes (P < 0.001). Lamina cribrosa was shallower in both non-arteritic anterior ischemic optic neuropathy and unaffected fellow eyes compared to healthy eyes (P < 0.001 and P = 0.04, respectively). No differences were found in the optic disk area. A forward lamina cribrosa placement and not a smaller disk could be involved in the pathogenesis of non-arteritic anterior ischemic optic neuropathy. A significantly larger Bruch's membrane opening diameter was found in primary open-angle glaucoma eyes compared with control eyes. This issue has clinical implications because Bruch's membrane opening has been considered a stable reference for disk-related measures.
Gender discrimination of eyes and mouths by individuals with autism.
Best, Catherine A; Minshew, Nancy J; Strauss, Mark S
2010-04-01
Evidence remains mixed about whether individuals with autism look less to eyes and whether they look more at mouths. Few studies have examined how spontaneous attention to facial features relates to face processing abilities. This study tested the ability to discriminate gender from facial features, namely eyes and mouths, by comparing accuracy scores of 17 children with autism and 15 adults with autism to 17 typically developing children and 15 typically developing adults. Results indicated that all participants regardless of diagnosis discriminated gender more accurately from eyes than from mouths. However, results indicated that compared to adults without autism, adults with autism were significantly worse at discriminating gender from eyes.
Telek, Hande Husniye; Yesilirmak, Nilufer; Sungur, Gulten; Ozdemir, Yaprak; Yesil, Nesibe Karahan; Ornek, Firdevs
2017-12-01
To compare the retinal toxicity due to hydroxychloroquine (HCQ) use in patients with systemic lupus erythematosus (SLE) and rheumatoid arthritis (RA) using multifocal electroretinography (mfERG), fundus autofluorescence (FAF) and optical coherence tomography (OCT). Patients who were using HCQ due to SLE and RA, and healthy subjects evaluated in this study. Central foveal thickness (CFT), inner-outer segment (IS-OS) junction irregularity, retinal nerve fiber layer thickness, mfERG and FAF measurements were performed to evaluate retinal toxicity. Study included 35 eyes of 35 SLE patients, 40 eyes of 40 RA patients and 20 eyes of 20 healthy subjects. In SLE group, retinal abnormality was found in three eyes with mfERG, in one eye with FAF and in four eyes with OCT. In RA group, retinal abnormality was found in 10 eyes with mfERG, in five eyes with FAF and in nine eyes with OCT. A statistically significant difference was found with respect to mfERG between "eyes with abnormal responses and without abnormal responses" and "eyes with abnormal responses and controls" (p < 0.05). A statistically significant difference was found with respect to CFT between "eyes with IS-OS junction irregularities and without IS-OS junction irregularities" and "eyes with/without IS-OS junction irregularities and controls" (p < 0.05). The use of HCQ seems to cause retinal toxicity more often in RA patients compared to SLE patients. For the early detection of retinal changes, OCT and mfERG can be used as screening tools due to their higher sensitivity rates compared to other tests.
NASA Technical Reports Server (NTRS)
Das, V. E.; Thomas, C. W.; Zivotofsky, A. Z.; Leigh, R. J.
1996-01-01
Video-based eye-tracking systems are especially suited to studying eye movements during naturally occurring activities such as locomotion, but eye velocity records suffer from broad band noise that is not amenable to conventional filtering methods. We evaluated the effectiveness of combined median and moving-average filters by comparing prefiltered and postfiltered records made synchronously with a video eye-tracker and the magnetic search coil technique, which is relatively noise free. Root-mean-square noise was reduced by half, without distorting the eye velocity signal. To illustrate the practical use of this technique, we studied normal subjects and patients with deficient labyrinthine function and compared their ability to hold gaze on a visual target that moved with their heads (cancellation of the vestibulo-ocular reflex). Patients and normal subjects performed similarly during active head rotation but, during locomotion, patients held their eyes more steadily on the visual target than did subjects.
Thavikulwat, Alisa T; Jacobs-El, Naima; Kim, Jane S; Agrón, Elvira; Hasan, Jesia; Meyerle, Catherine B; Valent, David; Cukras, Catherine A; Wiley, Henry E; Wong, Wai T; Chew, Emily Y
2017-01-01
To evaluate the risk factors, incidence, and rate of progression of geographic atrophy (GA) in eyes with neovascular age-related macular degeneration (nAMD) treated with ranibizumab. Post-hoc analysis of a prospective clinical study. 69 participants with nAMD in at least one eye. Participants were prospectively treated in the study eye with 0.5 mg intravitreal ranibizumab. Study eyes received 4 monthly injections followed by pro re nata injections until a fluid-free macula was achieved on optical coherence tomography. Risk factors assessed included baseline demographics, treatment, and ocular characteristics on imaging. Eyes were evaluated on fundus autofluorescence (FAF) for GA. The rate of GA area growth in study and fellow eyes was analyzed by linear regression of square-root transformed areas. Development of new-onset GA and rate of GA area growth measured on ocular imaging, including FAF images of the study eyes. Sixty-nine participants (mean age 78.8±7.8 years) with an average of 40.0±13.6 months of follow-up were analyzed. Twenty-two of 69 study eyes (32%) were treatment naïve. During their first year of the study, participants received an average of 9.2±3.3 injections in the study eye. Of 63 study eyes with quality baseline images, 22 (35%) had pre-existing GA. Of the remaining 41 eyes, 7 (17%) developed new-onset GA during study follow-up. Those who developed new GA were older (all ≥79 years old) and had received fewer study injections on average (6.9 vs. 10.4 injections at 1 year) compared to those who did not develop new GA. Of the 12 treatment naïve study eyes without GA at baseline, 1 (8.3%) developed new GA during the study. In 21 study eyes with quantifiable GA area, eyes with GA present at baseline (16/21) enlarged by 0.34±0.26 mm/year, compared to 0.19±0.12 mm/year in eyes developing new-onset GA (5/21). While 17% of study eyes without GA present at baseline receiving ranibizumab developed new GA, the role of ranibizumab in the development of GA is unclear. Further prospective longitudinal studies are required to determine the eyes most at risk of developing GA in the setting of anti-VEGF treatment.
Sendul, Selam Yekta; Cagatay, Halil Huseyin; Dirim, Burcu; Demir, Mehmet; Yıldız, Ali Atakhan; Acar, Zeynep; Cinar, Sonmez; Guven, Dilek
2014-01-01
Purpose. This study aims at comparing two different types of drainage tubes in conjunctivodacryocystorhinostomy, which are used for upper lacrimal system obstruction or damage, with respect to their respective postoperative problems and solutions. Methods. Nineteen eyes of 17 patients who underwent conjunctivodacryocystorhinostomy (CDCR) or conjunctivorhinostomy (CR) surgery with a Medpor coated tear drainage tube or silicon tube placement between October, 2010, and February, 2014, were included in this retrospective comparative study. Results. In the initial surgery, Medpor coated tear drainage tubes were used in 11 eyes by CDCR, whereas silicon tear drainage tubes were implanted into 2 eyes by CR and 6 eyes by CDCR. In group 1, proximal and distal obstructions developed postoperatively in 4 eyes, while 1 eye showed tube malposition and 3 eyes developed luminal obstruction by debris 3 times. In group 2, tube extrusion developed in 4 eyes, whereas tube malposition developed in 6 eyes and luminal obstruction by debris developed in 6 eyes at different times, for a total of 20 times. Conclusions. In our study, the most significant complication we observed in the use of silicon tear drainage tubes was tube extrusion,whereas the leading complication related to the use of Medpor coated tear drainage tubes was tube obstruction. PMID:25379518
Sendul, Selam Yekta; Cagatay, Halil Huseyin; Dirim, Burcu; Demir, Mehmet; Yıldız, Ali Atakhan; Acar, Zeynep; Cinar, Sonmez; Guven, Dilek
2014-01-01
This study aims at comparing two different types of drainage tubes in conjunctivodacryocystorhinostomy, which are used for upper lacrimal system obstruction or damage, with respect to their respective postoperative problems and solutions. Nineteen eyes of 17 patients who underwent conjunctivodacryocystorhinostomy (CDCR) or conjunctivorhinostomy (CR) surgery with a Medpor coated tear drainage tube or silicon tube placement between October, 2010, and February, 2014, were included in this retrospective comparative study. In the initial surgery, Medpor coated tear drainage tubes were used in 11 eyes by CDCR, whereas silicon tear drainage tubes were implanted into 2 eyes by CR and 6 eyes by CDCR. In group 1, proximal and distal obstructions developed postoperatively in 4 eyes, while 1 eye showed tube malposition and 3 eyes developed luminal obstruction by debris 3 times. In group 2, tube extrusion developed in 4 eyes, whereas tube malposition developed in 6 eyes and luminal obstruction by debris developed in 6 eyes at different times, for a total of 20 times. In our study, the most significant complication we observed in the use of silicon tear drainage tubes was tube extrusion,whereas the leading complication related to the use of Medpor coated tear drainage tubes was tube obstruction.
Outcomes of photorefractive keratectomy following laser in situ keratomileusis: a cohort study.
Iovieno, Alfonso; Teichman, Joshua C; Low, Stephanie; Yeung, Sonia N; Eve Lègarè, Marie; Lichtinger, Alejandro D; Slomovic, Allan R; Rootman, David S
2016-12-01
To analyze the outcomes of photorefractive keratectomy (PRK) on residual myopia and hyperopia post-laser in situ keratomileusis (LASIK) and to compare these results with PRK on eyes without previous laser refractive surgery. Retrospective comparative cohort study. Patients undergoing PRK between 2006 and 2010 were reviewed. Patients were divided into 4 groups, myopic or hyperopic PRK post-LASIK (mPRK-PL and hPRK-PL, respectively) and myopic or hyperopic PRK on corneas without previous laser refractive surgery (mPRK and hPRK, respectively). Uncorrected and corrected distance visual acuity, mean refractive spherical equivalent (MRSE), and mean keratometry and aberrations (total, higher order [HOA], coma, trefoil, and spherical aberration) were recorded at months 3 and 6 postoperatively, as were complications and attempted versus achieved MRSE. Thirty-three eyes of 25 patients who underwent PRK post-LASIK (21 eyes of 14 patients for hPRK-PL and 12 eyes of 11 patients for mPRK-PL) and 35 eyes of 21 patients who underwent PRK on virgin eyes (11 eyes of 8 patients for hPRK and 24 eyes of 13 patients for mPRK) were included in the study. The only significant differences in outcomes were found to be HOA at 3 months for hPRK-PL as compared with both hPRK and mPRK. Achieved MRSE was significantly different from expected MRSE for hPRK-PL at 3 months postoperatively. No haze- or flap-related complications were observed. Outcomes of PRK were not different in myopic and hyperopic corrections post-LASIK by 6 months or when compared with PRK in virgin eyes. HOA may render hPRK-PL results less predictable early in the postoperative period. Copyright © 2016 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.
Impact of First Eye versus Second Eye Cataract Surgery on Visual Function and Quality of Life.
Shekhawat, Nakul S; Stock, Michael V; Baze, Elizabeth F; Daly, Mary K; Vollman, David E; Lawrence, Mary G; Chomsky, Amy S
2017-10-01
To compare the impact of first eye versus second eye cataract surgery on visual function and quality of life. Cohort study. A total of 328 patients undergoing separate first eye and second eye phacoemulsification cataract surgeries at 5 veterans affairs centers in the United States. Patients with previous ocular surgery, postoperative endophthalmitis, postoperative retinal detachment, reoperation within 30 days, dementia, anxiety disorder, hearing difficulty, or history of drug abuse were excluded. Patients received complete preoperative and postoperative ophthalmic examinations for first eye and second eye cataract surgeries. Best-corrected visual acuity (BCVA) was measured 30 to 90 days preoperatively and postoperatively. Patients completed the National Eye Institute Visual Functioning Questionnaire (NEI-VFQ) 30 to 90 days preoperatively and postoperatively. The NEI-VFQ scores were calculated using a traditional subscale scoring algorithm and a Rasch-refined approach producing visual function and socioemotional subscale scores. Postoperative NEI-VFQ scores and improvement in NEI-VFQ scores comparing first eye versus second eye cataract surgery. Mean age was 70.4 years (±9.6 standard deviation [SD]). Compared with second eyes, first eyes had worse mean preoperative BCVA (0.55 vs. 0.36 logarithm of the minimum angle of resolution (logMAR), P < 0.001), greater mean BCVA improvement after surgery (-0.50 vs. -0.32 logMAR, P < 0.001), and slightly worse postoperative BCVA (0.06 vs. 0.03 logMAR, P = 0.039). Compared with first eye surgery, second eye surgery resulted in higher postoperative NEI-VFQ scores for nearly all traditional subscales (P < 0.001), visual function subscale (-3.85 vs. -2.91 logits, P < 0.001), and socioemotional subscale (-2.63 vs. -2.10 logits, P < 0.001). First eye surgery improved visual function scores more than second eye surgery (-2.99 vs. -2.67 logits, P = 0.021), but both first and second eye surgeries resulted in similar improvements in socioemotional scores (-1.62 vs. -1.51 logits, P = 0.255). Second eye cataract surgery improves visual function and quality of life well beyond levels achieved after first eye cataract surgery alone. For certain socioemotional aspects of quality of life, second eye cataract surgery results in comparable improvement to first eye cataract surgery. Copyright © 2017 American Academy of Ophthalmology. All rights reserved.
Kumar, Prachi; Bhargava, Rahul; Arora, Yogesh C; Kaushal, Sidharth; Kumar, Manjushri
2015-01-01
Prolonged contact lens wear is often accompanied by dryness of the eyes. The aim of this study was to compare conjunctival impression cytology (CIC) and tear film tests such as tear film break up time (TBUT) and Schirmer test for dry eye evaluation in contact lens wearers and measure their correlation with dry eye symptoms. A case control study was done at three referral eye centers. The eyes of 230 contact lens users were compared to 250 eyes of age- and sex-matched controls. Participants were recruited based on their response to a questionnaire of dry eye symptoms, (Dry Eye Scoring System, DESS(©)) and measurements of TBUT, Schirmer test, and CIC was done. A correlation analysis between symptom severity and tear film tests was performed. Pearson's coefficient, R(2) > 0.5 was considered significant. As compared to controls (r (2) = 0.010), Nelson grade correlated significantly with dry eye symptoms (r (2) = 0.765), among cases. However, there was moderate correlation between dry eye symptoms, Schirmer test, and TBUT (r (2) = 0.557 and 0.530, respectively) among cases and a weak correlation among controls (r (2) = 0.130 and 0.054, respectively). The sensitivity of TBUT was 86.4%, specificity was 82.4%, positive likelihood ratio (LR) was 4.50 [95% confidence interval (CI) 3.46-5.85)], and negative LR was 0.09. The sensitivity of the Schirmer test was 48.2%, specificity 88%, LR 2.12 (95% CI 1.48-2.96), and negative LR 0.83. CIC correlates better than Schirmer and TBUT with dry eye symptoms. It may be the most appropriate test for dry-eye evaluation in contact lens wearers.
Fogt, Jennifer S; Jones-Jordan, Lisa A; Barr, Joseph T
2018-01-01
New designs of eye wash stations have been developed in which the direction of water flow from the fountain has been reversed, with two water streams originating nasally in both eyes and flowing toward the temporal side of each eye. No study has been done to determine the ideal direction of water flow coming from the eye wash in relation to the eye. Ophthalmic eye examinations were conducted before and after the use of two eye wash stations with opposite water flow directionality. Fluorescein was instilled in both eyes before using an eye wash to measure the effectiveness of the water flow. Subjects were surveyed upon their experiences using the eye washes. Ophthalmic examination found no significant difference in the efficacy of the eye washes with nasal-to-temporal water flow when compared to temporal-to-nasal water flow direction.
Maekubo, Tomoyuki; Chuman, Hideki; Nao-I, Nobuhisa
2013-07-01
The aim of this study was to investigate the usefulness of laser speckle flowgraphy (LSFG) for the differentiation of acute nonarteritic ischemic optic neuropathy (NAION) from anterior optic neuritis (ON). To investigate blood flow in the optic disc under normal conditions, NAION, and anterior ON, we compared the tissue blood flow of the right eye with that of the left eye in the control group, and that of the affected eye with that of the unaffected eye in the NAION and anterior ON groups. In the normal control group, the tissue blood flow did not significantly differ between the right and left eyes. In the NAION group, all 6 patients had decreased optic disc blood flow in the NAION eye when compared with the unaffected eye. By contrast, in the anterior ON group, all 6 patients had increased optic disc blood flow in the anterior ON eye when compared with the unaffected eye. In the NAION group, the mean blur rate (MBR) of the affected eyes was 29.5 % lower than that of the unaffected eyes. In the anterior ON group, the MBR of the affected eyes was 15.9 % higher than that of the unaffected eyes. LSFG could be useful in differentiating between NAION and anterior ON. In addition, this imaging technique saves time and is noninvasive.
Lee, Yongeun; Kang, Seungbum; Park, Young-Hoon
2013-02-01
To evaluate the effect of adjunctive subtenon injection of triamcinolone acetonide (TA) in gas-filled eyes after vitrectomy for complicated proliferative diabetic retinopathy (PDR). This nonrandomized comparative study included 27 patients (27 eyes) who underwent pars plana vitrectomy and gas tamponade for treatment of PDR with tractional or combined tractional-rhegmatogenous retinal detachment and who received subtenon injection of TA (40 mg) at the end of surgery. The study group was compared with the control group (29 eyes), which was matched with the study group for preoperative and intraoperative parameters, but underwent pars plana vitrectomy and gas tamponade without a subtenon injection of TA. Retinal reattachments without reoperation were achieved in 25 eyes (92.6%) and 26 eyes (89.7%) at 6 months (p = 1.000) in the study and control groups, respectively. The study group and the control group did not differ significantly in the frequency of postoperative proliferative vitreoretinopathy, retinal redetachment rate, reoperation rate, macular pucker formation, postoperative vitreous hemorrhage, gain in visual acuity, intraocular pressure, and intraocular inflammation (p > 0.05). The clinical results of pars plana vitrectomy for complicated PDR are not improved significantly by an adjunctive subtenon TA injection in gas-filled eyes.
Müller, Jana Annina; Wendt, Dorothea; Kollmeier, Birger; Brand, Thomas
2016-01-01
The aim of this study was to validate a procedure for performing the audio-visual paradigm introduced by Wendt et al. (2015) with reduced practical challenges. The original paradigm records eye fixations using an eye tracker and calculates the duration of sentence comprehension based on a bootstrap procedure. In order to reduce practical challenges, we first reduced the measurement time by evaluating a smaller measurement set with fewer trials. The results of 16 listeners showed effects comparable to those obtained when testing the original full measurement set on a different collective of listeners. Secondly, we introduced electrooculography as an alternative technique for recording eye movements. The correlation between the results of the two recording techniques (eye tracker and electrooculography) was r = 0.97, indicating that both methods are suitable for estimating the processing duration of individual participants. Similar changes in processing duration arising from sentence complexity were found using the eye tracker and the electrooculography procedure. Thirdly, the time course of eye fixations was estimated with an alternative procedure, growth curve analysis, which is more commonly used in recent studies analyzing eye tracking data. The results of the growth curve analysis were compared with the results of the bootstrap procedure. Both analysis methods show similar processing durations. PMID:27764125
El Sayed, Y; Awadein, A
2013-01-01
Purpose To compare the results of silicone and polypropylene Ahmed glaucoma valves (AGV) implanted during the first 10 years of life. Methods A prospective study was performed on 50 eyes of 33 patients with paediatric glaucoma. Eyes were matched to either polypropylene or silicone AGV. In eyes with bilateral glaucoma, one eye was implanted with polypropylene and the other eye was implanted with silicone AGV. Results Fifty eyes of 33 children were reviewed. Twenty five eyes received a polypropylene valve, and 25 eyes received a silicone valve. Eyes implanted with silicone valves achieved a significantly lower intraocular pressure (IOP) compared with the polypropylene group at 6 months, 1 year, and 2 years postoperatively. The average survival time was significantly longer (P=0.001 by the log-rank test) for the silicone group than for the polypropylene group and the cumulative probability of survival by the log-rank test at the end of the second year was 80% (SE: 8.0, 95% confidence interval (CI): 64–96%) in the silicone group and 56% (SE: 9.8, 95% CI: 40–90%) in the polypropylene group. The difference in the number of postoperative interventions and complications between both groups was statistically insignificant. Conclusion Silicone AGVs can achieve better IOP control, and longer survival with less antiglaucoma drops compared with polypropylene valves in children younger than 10 years. PMID:23579403
Case control study of dry eye and related ocular surface abnormalities in Ibadan, Nigeria.
Bekibele, C O; Baiyeroju, A M; Ajaiyeoba, A; Akang, E E U; Ajayi, B G K
2010-02-01
Tear instability is associated with symptoms of ocular discomfort and irritation. Many patients with dry eyes remain untreated due to improper diagnoses. To identify symptoms and surface abnormalities associated with dry eyes. One hundred and fifty-six eyes of 78 subjects attending the Eye Clinic of the University College Hospital Ibadan were screened for dry eyes/tear instability using rose Bengal stain (graded 0-9), tear break-up time (TBUT), Schirmer's 1 tests, tear meniscus height and a standardised symptoms questionnaire. Grades 4-9 rose Bengal staining were considered as positive dry eye and were compared with grades 0-3 staining eyes as negative controls. Mean tear meniscus height, Schirmer's test and TBUT were lower among cases than their corresponding control eyes. The difference between the mean Schirmer's test values of cases and their controls were statistically significant (P = 0.00 for right eyes and P = 0.002 for left eyes). Rose Bengal grades were inversely correlated with the mean Schirmer's values (Pearson correlation -0.429, P = 0.05 for right eyes and -0.335, P = 0.03 for left eyes) and TBUT (Pearson correlation -0.316, P = 0.05 for right eyes and -0.212, P = 0.06 for left eyes). About 95.8% of the cases were symptomatic, as opposed to 70.4% of the controls (P = 0.01, Fisher's exact test) and 95.8% of dry right eyes compared to 61.1% of their controls had ocular surface abnormalities (P = 0.001), while 89.5% of dry left eyes compared to 62.7% of controls had surface abnormalities (P = 0.07). A close relationship exists between ocular irritation symptoms, surface abnormalities and functional evidence of tear instability. Such patients should be treated empirically or screened for dry eyes.
Thavikulwat, Alisa T.; Jacobs-El, Naima; Kim, Jane S.; Agrón, Elvira; Hasan, Jesia; Meyerle, Catherine B.; Valent, David; Cukras, Catherine A.; Wiley, Henry E.; Wong, Wai T.; Chew, Emily Y.
2016-01-01
Purpose To evaluate the risk factors, incidence, and rate of progression of geographic atrophy (GA) in eyes with neovascular age-related macular degeneration (nAMD) treated with ranibizumab. Design Post-hoc analysis of a prospective clinical study. Participants 69 participants with nAMD in at least one eye. Methods Participants were prospectively treated in the study eye with 0.5 mg intravitreal ranibizumab. Study eyes received 4 monthly injections followed by pro re nata injections until a fluid-free macula was achieved on optical coherence tomography. Risk factors assessed included baseline demographics, treatment, and ocular characteristics on imaging. Eyes were evaluated on fundus autofluorescence (FAF) for GA. The rate of GA area growth in study and fellow eyes was analyzed by linear regression of square-root transformed areas. Main Outcome Measures Development of new-onset GA and rate of GA area growth measured on ocular imaging, including FAF images of the study eyes. Results Sixty-nine participants (mean age 78.8±7.8 years) with an average of 40.0±13.6 months of follow-up were analyzed. Twenty-two of 69 study eyes (32%) were treatment naïve. During their first year of the study, participants received an average of 9.2±3.3 injections in the study eye. Of 63 study eyes with quality baseline images, 22 (35%) had pre-existing GA. Of the remaining 41 eyes, 7 (17%) developed new-onset GA during study follow-up. Those who developed new GA were older (all ≥79 years old) and had received fewer study injections on average (6.9 vs. 10.4 injections at 1 year) compared to those who did not develop new GA. Of the 12 treatment naïve study eyes without GA at baseline, 1 (8.3%) developed new GA during the study. In 21 study eyes with quantifiable GA area, eyes with GA present at baseline (16/21) enlarged by 0.34±0.26 mm/year, compared to 0.19±0.12 mm/year in eyes developing new-onset GA (5/21). Conclusions While 17% of study eyes without GA present at baseline receiving ranibizumab developed new GA, the role of ranibizumab in the development of GA is unclear. Further prospective longitudinal studies are required to determine the eyes most at risk of developing GA in the setting of anti-VEGF treatment. PMID:28630947
Ding, Hui; Pu, Aijun; He, Hong; Xie, Ruo Zhong; Yang, Jun; Liao, Aiping; Gao, Shaohui; Zhong, Xingwu
2012-08-01
This study compared the effect of orthokeratology (OK) lens wear on corneal topography and microstructure between the 1-night and 30-night wearers to predict any adverse responses of the eyes to long-term OK lens wear. Nine rhesus monkeys with one eye wearing an OK lens and the fellow eye wearing a rigid gas permeable (RGP) lens were used in this study. The lenses were worn for 11 hours, with the measurement of corneal curvature and thickness and axial components of the eye at 0 night (n = 9), 1 night (n = 9), and 30 nights (n = 6). Histology was performed at 1 and 30 nights of lens wear. Corneal surface power in the 3-mm central region was reduced in the OK eye when compared with the RGP eye (P < 0.05). Central corneal thickness was only reduced in 30 nights of OK lens wear (P < 0.05). Under light microscopy, the 1-night OK or RGP eyes showed normal morphology in all layers of the cornea. The 30-night OK eyes showed a thinned central corneal epithelium and a thickened but less stratified paracentral corneal epithelium when compared with the 30-night RGP eyes. Under electron microscopy, intercellular junctions of corneal epithelium in the 30-night OK eyes were much looser than those in the 1-night OK eyes. However, the density and morphology of hemidesmosomes were similar between the OK and RGP eyes at 30 nights of lens wear. Overnight OK can change the corneal curvature through anterior corneal remodeling, resulting in an effective correction of myopia. However, a decrease in intercellular junctions during long-term wear may compromise the functions of the corneal epithelium as a border mechanical barrier.
Collery, Ross F.; Veth, Kerry N.; Dubis, Adam M.; Carroll, Joseph; Link, Brian A.
2014-01-01
Refractive errors in vision can be caused by aberrant axial length of the eye, irregular corneal shape, or lens abnormalities. Causes of eye length overgrowth include multiple genetic loci, and visual parameters. We evaluate zebrafish as a potential animal model for studies of the genetic, cellular, and signaling basis of emmetropization and myopia. Axial length and other eye dimensions of zebrafish were measured using spectral domain-optical coherence tomography (SD-OCT). We used ocular lens and body metrics to normalize and compare eye size and relative refractive error (difference between observed retinal radial length and controls) in wild-type and lrp2 zebrafish. Zebrafish were dark-reared to assess effects of visual deprivation on eye size. Two relative measurements, ocular axial length to body length and axial length to lens diameter, were found to accurately normalize comparisons of eye sizes between different sized fish (R2 = 0.9548, R2 = 0.9921). Ray-traced focal lengths of wild-type zebrafish lenses were equal to their retinal radii, while lrp2 eyes had longer retinal radii than focal lengths. Both genetic mutation (lrp2) and environmental manipulation (dark-rearing) caused elongated eye axes. lrp2 mutants had relative refractive errors of −0.327 compared to wild-types, and dark-reared wild-type fish had relative refractive errors of −0.132 compared to light-reared siblings. Therefore, zebrafish eye anatomy (axial length, lens radius, retinal radius) can be rapidly and accurately measured by SD-OCT, facilitating longitudinal studies of regulated eye growth and emmetropization. Specifically, genes homologous to human myopia candidates may be modified, inactivated or overexpressed in zebrafish, and myopia-sensitizing conditions used to probe gene-environment interactions. Our studies provide foundation for such investigations into genetic contributions that control eye size and impact refractive errors. PMID:25334040
Thermal fluctuation based study of aqueous deficient dry eyes by non-invasive thermal imaging.
Azharuddin, Mohammad; Bera, Sumanta Kr; Datta, Himadri; Dasgupta, Anjan Kr
2014-03-01
In this paper we have studied the thermal fluctuation patterns occurring at the ocular surface of the left and right eyes for aqueous deficient dry eye (ADDE) patients and control subjects by thermal imaging. We conducted our experiment on 42 patients (84 eyes) with aqueous deficient dry eyes and compared with 36 healthy volunteers (72 eyes) without any history of ocular surface disorder. Schirmer's test, Tear Break-up Time, tear Meniscus height and fluorescein staining tests were conducted. Ocular surface temperature measurement was done, using an FL-IR thermal camera and thermal fluctuation in left and right eyes was calculated and analyzed using MATLAB. The time series containing the sum of squares of the temperature fluctuation on the ocular surface were compared for aqueous deficient dry eye and control subjects. Significant statistical difference between the fluctuation patterns for control and ADDE was observed (p < 0.001 at 95% confidence interval). Thermal fluctuations in left and right eyes are significantly correlated in controls but not in ADDE subjects. The possible origin of such correlation in control and lack of correlation in the ADDE subjects is discussed in the text. Copyright © 2014 Elsevier Ltd. All rights reserved.
Mayama, Chihiro; Tsutsumi, Tae; Saito, Hitomi; Asaoka, Ryo; Tomidokoro, Atsuo; Iwase, Aiko; Otani, Shinichiro; Miyata, Kazunori; Araie, Makoto
2014-01-01
This study was performed to first investigate the morphological differences in the optic nerve head between highly myopic non-glaucomatous controls and highly myopic glaucomatous eyes in comparison with the differences between emmetropic non-glaucomatous controls and emmetropic glaucomatous eyes using confocal scanning laser ophthalmoscopy. Further, the ability of the apparatus in glaucoma diagnosis in highly myopic eyes was compared with that in emmetropic eyes. Healthy subjects and age-matched patients with early-stage open-angle glaucoma were divided into two groups: emmetropic eyes (-1.0 to +1.0 diopters) and highly myopic eyes (-12.0 to -5.0 diopters).The participants were comprised of 65 emmetropic normal eyes, 59 emmetropic glaucomatous eyes, 62 highly myopic normal eyes, and 68 highly myopic glaucomatous eyes and eyes with pathologic myopia were carefully excluded. Confocal scanning laser tomographic parameters were compared among all subjects after adjustment for age and disc area. The ROC curves and sensitivity and specificity for glaucoma detection using several clinical methods were then compared between the emmetropic and highly myopic eyes. Rim area, cup/disc area ratio, mean cup depth, and cup shape measure of glaucoma eyes are significantly different from those of normal eyes in both highly myopic eyes and emmetropic eyes. Methodological overestimation of retinal nerve fiber layer cross sectional area due to optic disc tilting was suggested in the highly myopic eyes. The diagnostic performance of glaucoma using several discriminant methods significantly deteriorated in the highly myopic eyes. In the highly myopic glaucomatous eyes, confocal scanning laser tomographic parameters were significantly different from that of non-glaucomatous highly myopic eyes but diagnostic performance of glaucoma was deteriorated than that in emmetropic eyes. These findings demonstrate the utility and limitations of the apparatus in diagnosing glaucoma in highly myopic patients.
Mrugacz, Malgorzata; Bakunowicz-Lazarczyk, Alina
2005-01-01
The aim of this study was to quantitatively assess and compare the thickness of the retinal nerve fiber layer (RNFL) in normal and glaucomatous eyes of children using the optical coherence tomograph. The mean RNFL thickness of normal eyes (n=26) was compared with that of glaucomatous eyes (n=26). The eyes were classified into diagnostic groups based on conventional ophthalmological physical examination, Humphrey 30-2 visual fields, stereoscopic optic nerve head photography, and optical coherence tomography. The mean RNFL was significantly thinner in glaucomatous eyes than in normal eyes: 95+/-26.3 and 132+/-24.5 microm, respectively. More specifically, the RNFL was significantly thinner in glaucomatous eyes than in normal eyes in the inferior quadrant: 87+/-23.5 and 122+/-24.2 microm, respectively. The mean and inferior quadrant RFNL thicknesses as measured by the optical coherence tomograph showed a statistically significant correlation with glaucoma. Optical coherence tomography may contribute to tracking of juvenile glaucoma progression. Copyright (c) 2005 S. Karger AG, Basel.
Comparison of the biometric formulas used for applanation A-scan ultrasound biometry.
Özcura, Fatih; Aktaş, Serdar; Sağdık, Hacı Murat; Tetikoğlu, Mehmet
2016-10-01
The purpose of the study was to compare the accuracy of various biometric formulas for predicting postoperative refraction determined using applanation A-scan ultrasound. This retrospective comparative study included 485 eyes that underwent uneventful phacoemulsification with intraocular lens (IOL) implantation. Applanation A-scan ultrasound biometry and postoperative manifest refraction were obtained in all eyes. Biometric data were entered into each of the five IOL power calculation formulas: SRK-II, SRK/T, Holladay I, Hoffer Q, and Binkhorst II. All eyes were divided into three groups according to axial length: short (≤22.0 mm), average (22.0-25.0 mm), and long (≥25.0 mm) eyes. The postoperative spherical equivalent was calculated and compared with the predicted refractive error using each biometric formula. The results showed that all formulas had significantly lower mean absolute error (MAE) in comparison with Binkhorst II formula (P < 0.01). The lowest MAE was obtained with the SRK-II for average (0.49 ± 0.40 D) and short (0.67 ± 0.54 D) eyes and the SRK/T for long (0.61 ± 0.50 D) eyes. The highest postoperative hyperopic shift was seen with the SRK-II for average (46.8 %), short (28.1 %), and long (48.4 %) eyes. The highest postoperative myopic shift was seen with the Holladay I for average (66.4 %) and long (71.0 %) eyes and the SRK/T for short eyes (80.6 %). In conclusion, the SRK-II formula produced the lowest MAE in average and short eyes and the SRK/T formula produced the lowest MAE in long eyes. The SRK-II has the highest postoperative hyperopic shift in all eyes. The highest postoperative myopic shift is with the Holladay I for average and long eyes and SRK/T for short eyes.
Gergana, Kodjebacheva; Coleman, Anne L.; Ensrud, Kristine E.; Cauley, Jane A.; Yu, Fei; Stone, Katie L.; Pedula, Kathryn L.; Hochberg, Marc C.; Mangione, Carol M.
2010-01-01
Purpose To test the reliability and validity of questionnaires shortened from the National Eye Institute 25-item Vision Function Questionnaire (NEI VFQ-9 and NEI VFQ-8). Design A cross-sectional multi-center cohort study. Methods Reliability was assessed by Cronbach alpha coefficients. Validity was evaluated by studying the association of vision-targeted quality-of-life composite scores with objective visual function measurements. Study population: A total of 5,482 women between the ages of 65 and 100 years participated in the Year-10 clinic visit in the Study of Osteoporotic Fractures (SOF). A total of 3,631 women with complete data were included in the visual acuity (VA) and visual field (VF) analysis of the NEI VFQ-9, which is defined for those who care to drive. and 5,311 in the analysis of the NEI VFQ-8. To assess differences in prevalent eye diseases, which were ascertained for a random sample of SOF participants, 853 and 1,237 women were included in the NEI VFQ-9 and the NEI VFQ-8 analyses, respectively. Results Cronbach alpha coefficient for the NEI VFQ-9 scale was 0.83 and that of the NEI VFQ-8 was 0.84. Using both questionnaires, women with VA worse than 20/40 had lower composite scores compared to those with VA 20/40 or better (p<0.001). Participants with mild, moderate, and severe binocular VF loss had lower composite scores compared to those with no binocular VF loss (p<0.001).Compared to women without chronic eye diseases in both eyes, women with at least one chronic eye disease in at least one eye had lower composite scores. Conclusions Both questionnaires showed high reliability across items and validity with respect to clinical markers of eye disease Future research should compare the properties of these shortened surveys to those of the NEI VFQ-25. PMID:20103058
CHOROIDAL THICKNESS IN DIABETIC RETINOPATHY ASSESSED WITH SWEPT-SOURCE OPTICAL COHERENCE TOMOGRAPHY.
Laíns, Inês; Talcott, Katherine E; Santos, Ana R; Marques, João H; Gil, Pedro; Gil, João; Figueira, João; Husain, Deeba; Kim, Ivana K; Miller, Joan W; Silva, Rufino; Miller, John B
2018-01-01
To compare the choroidal thickness (CT) of diabetic eyes (different stages of disease) with controls, using swept-source optical coherence tomography. A multicenter, prospective, cross-sectional study of diabetic and nondiabetic subjects using swept-source optical coherence tomography imaging. Choroidal thickness maps, according to the nine Early Treatment Diabetic Retinopathy Study (ETDRS) subfields, were obtained using automated software. Mean CT was calculated as the mean value within the ETDRS grid, and central CT as the mean in the central 1 mm. Diabetic eyes were divided into four groups: no diabetic retinopathy (No DR), nonproliferative DR (NPDR), NPDR with diabetic macular edema (NPDR + DME), and proliferative DR (PDR). Multilevel mixed linear models were performed for analyses. The authors included 50 control and 160 diabetic eyes (n = 27 No DR, n = 51 NPDR, n = 61 NPDR + DME, and n = 21 PDR). Mean CT (ß = -42.9, P = 0.022) and central CT (ß = -50.2, P = 0.013) were statistically significantly thinner in PDR eyes compared with controls, even after adjusting for confounding factors. Controlling for age, DR eyes presented a significantly decreased central CT than diabetic eyes without retinopathy (β = -36.2, P = 0.009). Swept-source optical coherence tomography demonstrates a significant reduction of CT in PDR compared with controls. In the foveal region, the choroid appears to be thinner in DR eyes than in diabetic eyes without retinopathy.
Matsumoto, Yukihiro; Kodama, Asako; Goto, Eiki; Kawakita, Tetsuya; Dogru, Murat; Tsubota, Kazuo
2017-01-01
To evaluate the relation between ocular surface irregularity and visual disturbance in early stage Acanthamoeba keratitis (AK). Fifteen patients with culture-proven AK underwent routine ophthalmic examinations, including best-corrected visual acuity (BCVA) measurement, slitlamp biomicroscope examination, and corneal fluorescein dye staining test, in both the eyes. We also evaluated the corneal sensitivity with Cochet-Bonnet esthesiometer, tear functions by Schirmer's test, and ocular surface irregularity by corneal topography and compared the results with the contralateral healthy eyes in this study. The mean logarithm of the minimum angle of resolution BCVA (0.71±0.77) was significantly lower in the eyes with AK (P=0.002). Epithelial disorders were present in all eyes, and radial keratoneuritis in 14 eyes (93.3%). The mean corneal sensitivity (39.3±24.1 mm) was significantly lower in eyes with AK compared with the healthy eyes (P=0.005). The mean Schirmer's test value (22.5±12.0 mm) in eyes with AK was significantly higher compared with the healthy eyes (P=0.01). The ocular surface irregularity indices (the surface regularity index, 2.47±0.42; the surface asymmetry index, 3.24±1.31) were significantly higher in eyes with AK compared with contralateral healthy eyes (P<0.0001 and P<0.0001, respectively). The ocular surface disease in AK is associated with decrease in corneal sensitivity and increase in Schirmer's test value and ocular surface irregularity indices. The visual disturbance in AK may owe not only to corneal haze but also to ocular surface irregularity.
Wang, Xiaolei; Kong, Xiangmei; Jiang, Chunhui; Li, Mengwei; Yu, Jian; Sun, Xinghuai
2016-03-11
The aim of this study was to evaluate the peripapillary and parafoveal perfusion of young, healthy myopic subjects with spectral domain optical coherence tomography (OCT) angiography. A prospective comparative study was conducted from December 2014 to January 2015. Participants recruited from a population-based study performed by the Eye, Ear, Nose and Throat Hospital of Fudan University in Shanghai. A total of 78 Chinese normal subjects (78 eyes) with different refraction were included. Myopia was divided into 4 groups on the basis of the refractive status: 20 eyes with emmetropia (mean spherical equivalent (MSE) 0.50D to -0.50D), 20 eyes with mild myopia (MSE -0.75D to -2.75D), 20 eyes with moderate myopia (MSE -3.00D to -5.75D), and 18 eyes with high myopia (MSE≤-6.00D). Peripapillary and parafoveal retinal and choroidal perfusion parameters and their relationships with axial length (AL) and retinal nerve fibre layer (RNFL) thickness were analysed. Significant differences were found for the retinal flow index and vessel density in the peripapillary area among the 4 groups, but not in the parafoveal area. The high myopia group had the lowest peripapillary retinal flow index and vessel density. In addition, there was a negative correlation (β=-0.002, p=0.047) between the AL and peripapillary retinal flow index and a positive correlation between RNFL thickness and the peripapillary retinal perfusion parameters (flow index: β=0.001, p=0.006; vessel density: β=0.350, p=0.002) even after adjustment for other variables. Highly myopic eyes have a decreased peripapillary retinal perfusion compared with emmetropic eyes. Such vascular features might increase the susceptibility to vascular-related eye diseases. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Application of 3-Dimensional Printing Technology to Construct an Eye Model for Fundus Viewing Study
Li, Xinhua; Gao, Zhishan; Yuan, Dongqing; Liu, Qinghuai
2014-01-01
Objective To construct a life-sized eye model using the three-dimensional (3D) printing technology for fundus viewing study of the viewing system. Methods We devised our schematic model eye based on Navarro's eye and redesigned some parameters because of the change of the corneal material and the implantation of intraocular lenses (IOLs). Optical performance of our schematic model eye was compared with Navarro's schematic eye and other two reported physical model eyes using the ZEMAX optical design software. With computer aided design (CAD) software, we designed the 3D digital model of the main structure of the physical model eye, which was used for three-dimensional (3D) printing. Together with the main printed structure, polymethyl methacrylate(PMMA) aspherical cornea, variable iris, and IOLs were assembled to a physical eye model. Angle scale bars were glued from posterior to periphery of the retina. Then we fabricated other three physical models with different states of ammetropia. Optical parameters of these physical eye models were measured to verify the 3D printing accuracy. Results In on-axis calculations, our schematic model eye possessed similar size of spot diagram compared with Navarro's and Bakaraju's model eye, much smaller than Arianpour's model eye. Moreover, the spherical aberration of our schematic eye was much less than other three model eyes. While in off- axis simulation, it possessed a bit higher coma and similar astigmatism, field curvature and distortion. The MTF curves showed that all the model eyes diminished in resolution with increasing field of view, and the diminished tendency of resolution of our physical eye model was similar to the Navarro's eye. The measured parameters of our eye models with different status of ametropia were in line with the theoretical value. Conclusions The schematic eye model we designed can well simulate the optical performance of the human eye, and the fabricated physical one can be used as a tool in fundus range viewing research. PMID:25393277
Application of 3-dimensional printing technology to construct an eye model for fundus viewing study.
Xie, Ping; Hu, Zizhong; Zhang, Xiaojun; Li, Xinhua; Gao, Zhishan; Yuan, Dongqing; Liu, Qinghuai
2014-01-01
To construct a life-sized eye model using the three-dimensional (3D) printing technology for fundus viewing study of the viewing system. We devised our schematic model eye based on Navarro's eye and redesigned some parameters because of the change of the corneal material and the implantation of intraocular lenses (IOLs). Optical performance of our schematic model eye was compared with Navarro's schematic eye and other two reported physical model eyes using the ZEMAX optical design software. With computer aided design (CAD) software, we designed the 3D digital model of the main structure of the physical model eye, which was used for three-dimensional (3D) printing. Together with the main printed structure, polymethyl methacrylate(PMMA) aspherical cornea, variable iris, and IOLs were assembled to a physical eye model. Angle scale bars were glued from posterior to periphery of the retina. Then we fabricated other three physical models with different states of ammetropia. Optical parameters of these physical eye models were measured to verify the 3D printing accuracy. In on-axis calculations, our schematic model eye possessed similar size of spot diagram compared with Navarro's and Bakaraju's model eye, much smaller than Arianpour's model eye. Moreover, the spherical aberration of our schematic eye was much less than other three model eyes. While in off- axis simulation, it possessed a bit higher coma and similar astigmatism, field curvature and distortion. The MTF curves showed that all the model eyes diminished in resolution with increasing field of view, and the diminished tendency of resolution of our physical eye model was similar to the Navarro's eye. The measured parameters of our eye models with different status of ametropia were in line with the theoretical value. The schematic eye model we designed can well simulate the optical performance of the human eye, and the fabricated physical one can be used as a tool in fundus range viewing research.
Karn, Pankaj Ranjan; Kim, Hyun Do; Kang, Han; Sun, Bo Kyung; Jin, Su-Eon; Hwang, Sung-Joo
2014-01-01
Background The objective of this study was to compare the efficacy of cyclosporin (CsA)-encapsulated liposomes with the commercially available CsA emulsion (Restasis®) for the treatment of dry eye syndrome in rabbits. Methods Liposomes containing CsA were prepared by the supercritical fluid (SCF) method consisted of phosphatidylcholine from soybean (SCF-S100) and egg lecithins (SCF-EPCS). An in vitro permeation study was carried out using artificial cellulose membrane in Franz diffusion cells. Dry eye syndrome was induced in male albino rabbits and further subdivided into untreated, Restasis®-treated, EPCS, and S100-treated groups. Tear formation in the dry-eye-induced rabbits was evaluated using the Schirmer tear test. All formulations were also evaluated by ocular irritation tests using the Draize eye and winking methods with the determination of CsA concentration in rabbit tears. Results After the treatment, the Schirmer tear test value significantly improved in EPCS-treated (P=0.005) and S100-treated (P=0.018) groups compared to the Restasis®-treated group. The AUC0–24 h for rabbit’s tear film after the administration of SCF-S100 was 32.75±9.21 μg·h/mg which was significantly higher than that of 24.59±8.69 μg·h/mg reported with Restasis®. Liposomal CsA formulations used in this study showed lower irritation in rabbit eyes compared with Restasis®. Conclusion These results demonstrate that the novel SCF-mediated liposomal CsA promises a significant improvement in overcoming the challenges associated with the treatment of dry eyes. PMID:25143728
Karn, Pankaj Ranjan; Kim, Hyun Do; Kang, Han; Sun, Bo Kyung; Jin, Su-Eon; Hwang, Sung-Joo
2014-01-01
The objective of this study was to compare the efficacy of cyclosporin (CsA)-encapsulated liposomes with the commercially available CsA emulsion (Restasis) for the treatment of dry eye syndrome in rabbits. Liposomes containing CsA were prepared by the supercritical fluid (SCF) method consisted of phosphatidylcholine from soybean (SCF-S100) and egg lecithins (SCF-EPCS). An in vitro permeation study was carried out using artificial cellulose membrane in Franz diffusion cells. Dry eye syndrome was induced in male albino rabbits and further subdivided into untreated, Restasis-treated, EPCS, and S100-treated groups. Tear formation in the dry-eye-induced rabbits was evaluated using the Schirmer tear test. All formulations were also evaluated by ocular irritation tests using the Draize eye and winking methods with the determination of CsA concentration in rabbit tears. After the treatment, the Schirmer tear test value significantly improved in EPCS-treated (P=0.005) and S100-treated (P=0.018) groups compared to the Restasis-treated group. The AUC₀₋₂₄ h for rabbit's tear film after the administration of SCF-S100 was 32.75±9.21 μg·h/mg which was significantly higher than that of 24.59±8.69 μg·h/mg reported with Restasis. Liposomal CsA formulations used in this study showed lower irritation in rabbit eyes compared with Restasis. These results demonstrate that the novel SCF-mediated liposomal CsA promises a significant improvement in overcoming the challenges associated with the treatment of dry eyes.
Miyake, Kensaku; Yokoi, Norihiko
2017-01-01
To investigate influences of 3% diquafosol sodium ophthalmic solution (DQS) on ocular surface after cataract surgery and effects on postoperative dry eye. This study had two consecutive prospective study phases. The former was an observational study from before cataract surgery to 4 weeks after surgery and the latter was a randomized open-label study from 4 to 8 weeks after surgery. Subjects were 433 eyes of 433 patients undergoing cataract surgery with intraocular lens implantation. Dry eye examination of tear breakup time (BUT), corneal and conjunctival fluorescein staining scores, total subjective symptom score (12 symptoms), and Schirmer I test were conducted before surgery and 4 weeks after surgery. Patient demographics and these examination results were used to analyze risk factors to predict postoperative dry eye. In a randomized study, 154 eyes diagnosed with dry eye postoperatively were applied either DQS or artificial tears (AT) six times daily for 4 weeks. The data of the examinations were compared. At 4 weeks after surgery, BUT was shortened significantly ( P =0.036), fluorescein staining score increased significantly ( P =0.012), but total subjective symptom score was significantly improved ( P <0.001). The majority of postoperative dry eye was shortened BUT type (53.1%). The dry eye prevalence after surgery decreased (55.7%) compared with before surgery (69.7%). Females and the patient with dry eye symptoms before surgery had significant risk factors for postoperative dry eye. In a randomized study, BUT was significantly prolonged in the DQS group ( P =0.015), but not in the AT group. Fluorescein staining score was significantly improved in both groups ( P <0.001). Total subjective symptom score was significantly decreased in the AT group ( P <0.001), but not in the DQS group. Our study suggests that cataract surgery has harmful effects on tear film stability and ocular surface, and DQS has a capability to improve them.
Miyake, Kensaku; Yokoi, Norihiko
2017-01-01
Purpose To investigate influences of 3% diquafosol sodium ophthalmic solution (DQS) on ocular surface after cataract surgery and effects on postoperative dry eye. Design This study had two consecutive prospective study phases. The former was an observational study from before cataract surgery to 4 weeks after surgery and the latter was a randomized open-label study from 4 to 8 weeks after surgery. Methods Subjects were 433 eyes of 433 patients undergoing cataract surgery with intraocular lens implantation. Dry eye examination of tear breakup time (BUT), corneal and conjunctival fluorescein staining scores, total subjective symptom score (12 symptoms), and Schirmer I test were conducted before surgery and 4 weeks after surgery. Patient demographics and these examination results were used to analyze risk factors to predict postoperative dry eye. In a randomized study, 154 eyes diagnosed with dry eye postoperatively were applied either DQS or artificial tears (AT) six times daily for 4 weeks. The data of the examinations were compared. Results At 4 weeks after surgery, BUT was shortened significantly (P=0.036), fluorescein staining score increased significantly (P=0.012), but total subjective symptom score was significantly improved (P<0.001). The majority of postoperative dry eye was shortened BUT type (53.1%). The dry eye prevalence after surgery decreased (55.7%) compared with before surgery (69.7%). Females and the patient with dry eye symptoms before surgery had significant risk factors for postoperative dry eye. In a randomized study, BUT was significantly prolonged in the DQS group (P=0.015), but not in the AT group. Fluorescein staining score was significantly improved in both groups (P<0.001). Total subjective symptom score was significantly decreased in the AT group (P<0.001), but not in the DQS group. Conclusion Our study suggests that cataract surgery has harmful effects on tear film stability and ocular surface, and DQS has a capability to improve them. PMID:28360509
Attention to eye contact in the West and East: autonomic responses and evaluative ratings.
Akechi, Hironori; Senju, Atsushi; Uibo, Helen; Kikuchi, Yukiko; Hasegawa, Toshikazu; Hietanen, Jari K
2013-01-01
Eye contact has a fundamental role in human social interaction. The special appearance of the human eye (i.e., white sclera contrasted with a coloured iris) implies the importance of detecting another person's face through eye contact. Empirical studies have demonstrated that faces making eye contact are detected quickly and processed preferentially (i.e., the eye contact effect). Such sensitivity to eye contact seems to be innate and universal among humans; however, several studies suggest that cultural norms affect eye contact behaviours. For example, Japanese individuals exhibit less eye contact than do individuals from Western European or North American cultures. However, how culture modulates eye contact behaviour is unclear. The present study investigated cultural differences in autonomic correlates of attentional orienting (i.e., heart rate) and looking time. Additionally, we examined evaluative ratings of eye contact with another real person, displaying an emotionally neutral expression, between participants from Western European (Finnish) and East Asian (Japanese) cultures. Our results showed that eye contact elicited stronger heart rate deceleration responses (i.e., attentional orienting), shorter looking times, and higher ratings of subjective feelings of arousal as compared to averted gaze in both cultures. Instead, cultural differences in the eye contact effect were observed in various evaluative responses regarding the stimulus faces (e.g., facial emotion, approachability etc.). The rating results suggest that individuals from an East Asian culture perceive another's face as being angrier, unapproachable, and unpleasant when making eye contact as compared to individuals from a Western European culture. The rating results also revealed that gaze direction (direct vs. averted) could influence perceptions about another person's facial affect and disposition. These results suggest that cultural differences in eye contact behaviour emerge from differential display rules and cultural norms, as opposed to culture affecting eye contact behaviour directly at the physiological level.
Attention to Eye Contact in the West and East: Autonomic Responses and Evaluative Ratings
Akechi, Hironori; Senju, Atsushi; Uibo, Helen; Kikuchi, Yukiko; Hasegawa, Toshikazu; Hietanen, Jari K.
2013-01-01
Eye contact has a fundamental role in human social interaction. The special appearance of the human eye (i.e., white sclera contrasted with a coloured iris) implies the importance of detecting another person's face through eye contact. Empirical studies have demonstrated that faces making eye contact are detected quickly and processed preferentially (i.e., the eye contact effect). Such sensitivity to eye contact seems to be innate and universal among humans; however, several studies suggest that cultural norms affect eye contact behaviours. For example, Japanese individuals exhibit less eye contact than do individuals from Western European or North American cultures. However, how culture modulates eye contact behaviour is unclear. The present study investigated cultural differences in autonomic correlates of attentional orienting (i.e., heart rate) and looking time. Additionally, we examined evaluative ratings of eye contact with another real person, displaying an emotionally neutral expression, between participants from Western European (Finnish) and East Asian (Japanese) cultures. Our results showed that eye contact elicited stronger heart rate deceleration responses (i.e., attentional orienting), shorter looking times, and higher ratings of subjective feelings of arousal as compared to averted gaze in both cultures. Instead, cultural differences in the eye contact effect were observed in various evaluative responses regarding the stimulus faces (e.g., facial emotion, approachability etc.). The rating results suggest that individuals from an East Asian culture perceive another's face as being angrier, unapproachable, and unpleasant when making eye contact as compared to individuals from a Western European culture. The rating results also revealed that gaze direction (direct vs. averted) could influence perceptions about another person's facial affect and disposition. These results suggest that cultural differences in eye contact behaviour emerge from differential display rules and cultural norms, as opposed to culture affecting eye contact behaviour directly at the physiological level. PMID:23516627
Bhargava, Rahul; Kumar, Prachi; Kaur, Avinash; Kumar, Manjushri; Mishra, Anurag
2014-07-01
To compare the diagnostic value and accuracy of dry eye scoring system (DESS), conjunctival impression cytology (CIC), tear film breakup time (TBUT), and Schirmer's test in computer users. A case-control study was done at two referral eye centers. Eyes of 344 computer users were compared to 371 eyes of age and sex matched controls. Dry eye questionnaire (DESS) was administered to both groups and they further underwent measurement of TBUT, Schirmer's, and CIC. Correlation analysis was performed between DESS, CIC, TBUT, and Schirmer's test scores. A Pearson's coefficient of the linear expression (R (2)) of 0.5 or more was statistically significant. The mean age in cases (26.05 ± 4.06 years) was comparable to controls (25.67 ± 3.65 years) (P = 0.465). The mean symptom score in computer users was significantly higher as compared to controls (P < 0.001). Mean TBUT, Schirmer's test values, and goblet cell density were significantly reduced in computer users (P < 0.001). TBUT, Schirmer's, and CIC were abnormal in 48.5%, 29.1%, and 38.4% symptomatic computer users respectively as compared to 8%, 6.7%, and 7.3% symptomatic controls respectively. On correlation analysis, there was a significant (inverse) association of dry eye symptoms (DESS) with TBUT and CIC scores (R (2) > 0.5), in contrast to Schirmer's scores (R(2) < 0.5). Duration of computer usage had a significant effect on dry eye symptoms severity, TBUT, and CIC scores as compared to Schirmer's test. DESS should be used in combination with TBUT and CIC for dry eye evaluation in computer users.
Corneal curvature, pachymetry, and endothelial cell density in Marfan syndrome.
Konradsen, Tiina R; Koivula, Annemari; Kugelberg, Maria; Zetterström, Charlotta
2012-06-01
To evaluate corneal curvature, pachymetry, and endothelial cell density (ECD) in Marfan syndrome (MFS). A case-control study in which K values, pachymetry, and ECD were compared in 39 MFS eyes and 40 control eyes matched for age and refraction was conducted. MFS eyes with lens subluxation also were compared with eyes without subluxation. The mean K(med) value in MFS eyes was lower than in the control eyes, 42.2 ± 1.9 versus 43.4 ± 1.4 dioptres (D), respectively (p = 0.02). Fifteen MFS eyes (38%) and three control eyes (8%) had K(med) values below 41.5 D (p = 0.0012). MFS eyes had generally more corneal astigmatism than control eyes, 1.1 ± 0.9 versus 0.8 ± 0.4 D (p = 0.035), and MFS eyes with lens subluxation had more corneal astigmatism than those without, 1.6 ± 1.1 versus 0.6 ± 0.3 D (p = 0.0002). Nine MFS eyes with corneal astigmatism exceeding 1.5 D also had a subluxated lens. No eyes had keratoconus. The mean pachymetry value was lower in MFS eyes compared to the controls, 485 ± 54.5 versus 514 ± 37.3 μm (p = 0.007); 24 MFS eyes (62%) and 10 control eyes (25%) had measurements below 500 μm (p = 0.01). The mean ECD values were similar in MFS and control eyes, 2815 ± 430 versus 2858 ± 458 cells/mm(2) (p = 0.66). The mean K value, pachymetry, and ECD values did not differ between MFS eyes with and without lens subluxation. Decreased K values and pachymetry could indicate MFS regardless of subluxation. High corneal astigmatism is associated with subluxation in MFS. Subluxation should be identified in MFS eyes with high corneal astigmatism. © 2010 The Authors. Journal compilation © 2010 Acta Ophthalmol.
Comparison of noncontact infrared and remote sensor thermometry in normal and dry eye patients.
Singh, G; Singh Bhinder, H
To evaluate the role of closed chamber infrared and remote sensor thermometry in normal and dry eye patients. The study was conducted on 51 dry eye cases (102 eyes), 26 men and 25 women aged 19 to 65 years (35.3614.36), and 51 normal (102 eyes) age- and sex-matched control subjects. The criteria for dry eye were Schirm e r-1 (<10 m/5 min), FTBUT (<10 sec), nd lissamine green score (>2). The remote sensor and infrared thermometry was done in losed chamber around the eye in closed and open eye positions. In normal eyes, closed chamber infrared thermometry recorded temperature 34.770.37 C in closed eye position and 35.020.39 C in open eye position as compared to 27.912.46 C in closed eye position and 28.012.46 C in open position with remote sensor thermometry. The difference in temperature from closed to open position was 0.250.90 C in infrared thermometry and 0.100.00 C with remote sensor thermometry, which was statistically significant (p<0.0000). In dry eye, the infrared therm o m e t ry recorded 35.080.61 C temperature in closed eye position and 35.530.63 C in open eye position as compared to 27.412.48 C in open and closed eye position with remote sensor thermometry. The difference in temperature from closed to open eye position was 0.450.14 C (p<0.0000) with infrared thermometry as compared to no change 0.000.00 C with remote sensor thermometry (p<0.0000). Remote sensor thermometry proved better for diagnosis of dry eye disease as it showed no change in temperature under closed chamber in closed and open position (p=0.0000). Infrared thermometry was better in recording the absolute temperature from any point on the eye.
Comparison of noncontact infrared and remote sensor thermometry in normal and dry eye patients.
Singh, G; Bhinder, H Singh
2005-01-01
To evaluate the role of closed chamber infrared and remote sensor thermometry in normal and dry eye patients. The study was conducted on 51 dry eye cases (102 eyes), 26 men and 25 women aged 19 to 65 years (35.36+/-14.36), and 51 normal (102 eyes) age- and sex-matched control subjects. The criteria for dry eye were Schirmer-1 (<10 m/5 min), FTBUT (<10 sec), nd lissamine green score (>2). The remote sensor and infrared thermometry was done in closed chamber around the eye in closed and open eye positions. In normal eyes, closed chamber infrared thermometry recorded temperature 34.77+/-0.37 degrees C in closed eye position and 35.02+/-0.39 degrees C in open eye position as compared to 27.91+/-2.46 degrees C in closed eye position and 28.01+/-2.46 degrees C in open position with remote sensor thermometry. The difference in temperature from closed to open position was 0.25+/-0.90 degrees C in infrared thermometry and 0.10+/-0.00 degrees C with remote sensor thermometry, which was statistically significant (p<0.0000). In dry eye, the infrared thermometry recorded 35.08+/-0.61 degrees C temperature in closed eye position and 35.53+/-0.63 degrees C in open eye position as compared to 27.41+/-2.48 degrees C in open and closed eye position with remote sensor thermometry. The difference in temperature from closed to open eye position was 0.45+/-0.14 degrees C (p<0.0000) with infrared thermometry as compared to no change 0.00+/-0.00 degrees C with remote sensor thermometry (p<0.0000). Remote sensor thermometry proved better for diagnosis of dry eye disease as it showed no change in temperature under closed chamber in closed and open position (p=0.0000). Infrared thermometry was better in recording the absolute temperature from any point on the eye.
The spectrum of eye injuries in Sagamu, Nigeria.
Ajibode, H A; Thanni, L O; Onabolu, O O; Bodunde, O T; Otulana, T O
2013-01-01
Eye injuries are major causes of visual morbidity and monocular blindness worldwide. The common causes of eye injuries needs to be well defined in each community so as to plan for prevention of high morbidity and blindness as part of blindness prevention programme. It is necessary to compare the trend in causes of ocular injuries in Ogun State after a similar study over 15 years before. The part played by road traffic accidents [RTA] compared to other causes is also to be analysed. This prospective study was carried out between July 2004 and June 2005. All cases presenting to the Accident and Emergency Unit and Eye Clinic of Olabisi Onabanjo University Teaching Hospital, Sagamu, and the 2 private eye clinics in Sagamu town, presenting with any form of eye injuries during the study period were included. The biodata, cause and type of eye injury, time of injury, time of presentation and treatment offered were obtained using a questionnaire. The results were analysed with Epi-Info 2002. One hundred and twelve patients were studied. Eighty-one [72.3%] of the victims were males; most of them, 36[33.0%] were students and 32 [29.4%] artisans. The common causes of eye injuries were RTA 35[31.3%], assault 22[19.6%], vegetative agents 18 [16.1%] and machine tools 11[9.8%]. Most patients presented either within 24 hours, 56[50.0%] or within a week, 34[30.4%] of injury, and mostly during the day 86[97.6%]. Most injuries were found in the anterior segment 95[84.8%] and most commonly, victims 65[58%] required only medications as treatment. Majority of eye injuries found in Sagamu are treatable and can be handled by an experienced non-ophthalmologist successfully and most are now accounted for by RTAs and assault which indicate some changes in common causes compared to previous studies in Nigeria.
Rate and Pattern of Rim Area Loss in Healthy and Progressing Glaucoma Eyes
Hammel, Na’ama; Belghith, Akram; Bowd, Christopher; Medeiros, Felipe A.; Sharpsten, Lucie; Mendoza, Nadia; Tatham, Andrew J.; Khachatryan, Naira; Liebmann, Jeffrey M.; Girkin, Christopher A.; Weinreb, Robert N.; Zangwill, Linda M.
2015-01-01
Objective To characterize the rate and pattern of age-related and glaucomatous neuroretinal rim area changes in subjects of African descent (AD) and European descent (ED). Design Prospective longitudinal study. Subjects 296 eyes of 157 healthy subjects (88 AD and 69 ED) and 73 progressing glaucoma eyes of 67 subjects (24 AD and 43 ED) from the Diagnostic Innovations in Glaucoma Study (DIGS) and the African Descent and Glaucoma Evaluation Study (ADAGES) were included. Methods Global and sectoral rim area was measured using confocal laser scanning ophthalmoscopy (CSLO). Progression of glaucomatous optic disc damage was determined by masked stereophoto review. The rates of absolute rim area loss and percent rim area loss in healthy and progressing glaucomatous eyes were compared using multivariable nested mixed-effects models. Main Outcome Measures Rate of rim area loss over time. Results The median (inter-quartile range) follow-up time was 5.0 years (2.0–7.4) for healthy eyes and 8.3 years (7.5–9.9) for progressing glaucoma eyes. The mean rate of global rim area loss was significantly faster in progressing glaucoma eyes compared with healthy eyes for both rim area loss (−10.2 ×10−3 mm2/year vs. −2.8 ×10−3 mm2/year, respectively, P<.001) and percent rim area loss (−1.1 %/year vs. −0.2 %/year, respectively, P<.001), but there was considerable overlap between the two groups. 63% of progressing glaucoma eyes had a rate of change faster than the 5th quantile of healthy eyes. For both healthy and progressing eyes, the pattern of rim area loss and percent rim area loss was similar; it tended to be fastest in the superior temporal and inferior temporal sectors. The rate of change was similar in AD and ED progressing eyes. Conclusions Compared with healthy eyes, the mean rate of global rim area loss was 3.7 times faster and the mean rate of global percent rim area loss was 5.4 times faster in progressing glaucoma eyes. A reference database of healthy eyes can be used to help clinicians distinguish age-related rim area loss from rim area loss due to glaucoma. PMID:26746597
Sports eyewear protective standards.
Dain, Stephen J
2016-01-01
Eye injuries sustained during sport comprise up to 20 per cent of all injuries to the eye serious enough for medical attention to be sought. The prevalence of eye injuries in sport is not easily assessed due to lack of authoritative participation rates, so most studies report total numbers in a time period. The evidence on the proportion of all ocular injuries that are from sport is reviewed. The relative frequencies in different sports are compared in a qualitative manner and the sports with greater numbers of ocular injuries are detailed. In common with occupational injuries to the eye, most sports eye injuries are considered preventable. The hierarchy of action for occupational risk is detailed and adapted to use in a sports scenario. All the available international, regional and national standards on sports eye protection are detailed and their provisions compared. The major function of the standards is to provide adequate protection against the hazard of the sport concerned. These are detailed and compared as a function of energy transfer. Eye protection must not introduce additional or secondary hazards (for instance, fracturing into sharp fragments on impact) and not introduce features that would deter the wearing of eye protection (for instance, restricting field of view to impede playing the sport). The provisions of the standards intended to limit secondary hazards are detailed and compared. The need for future work in standards writing and the activities of the International Standardization Organization in sports eye protection are detailed. © 2016 Optometry Australia.
A Comparison of Functional and Structural Measures for Identifying Progression of Glaucoma
Xin, Daiyan; Greenstein, Vivienne C.; Ritch, Robert; Liebmann, Jeffrey M.; De Moraes, Carlos Gustavo
2011-01-01
Purpose. To compare glaucoma progression by functional and structural tests. Methods. The authors prospectively studied 33 glaucoma patients (55 eyes); 20 eyes (15 patients) had disc hemorrhage, and 35 eyes (18 patients) had exfoliation glaucoma. The following tests were performed at two baseline and three follow-up examinations: frequency doubling perimetry (FDT), 24-2 Humphrey visual fields (HVF), multifocal visual evoked potentials (mfVEP), and optical coherence tomography (OCT). To identify progression, the baseline measurements were averaged and compared to those obtained at the final examination. Stereophotographs of the optic disc were obtained at baseline and compared with those at the final examination. Results. Patients were followed up for 21.1 ± 1.8 months. For HVF there were significant changes in mean deviation (MD) in eight (14.5%) eyes but in pattern standard deviation (P/SD) in only two (3.6%) eyes. For FDT, there were significant changes in MD in 13 (23.6%) eyes. Five eyes showed changes in MD for HVF and FDT. For mfVEP, there was an increase in abnormal points in nine (16.4%) eyes. Six of these eyes did not show significant HVF or FDT changes. For OCT, RNFL average thickness values were significantly decreased in nine (16.4%) eyes. Nine (16.4%) eyes showed progression on stereophotography; four of these eyes did not show significant changes on OCT and functional tests. Conclusions. Each test showed evidence of progression in some eyes. However, agreement among tests and stereophotography regarding which eyes showed progression was poor, illustrating the importance of following up patients with a combination of functional and structural tests. PMID:20847115
The Effect of Eye Contact Is Contingent on Visual Awareness
Xu, Shan; Zhang, Shen; Geng, Haiyan
2018-01-01
The present study explored how eye contact at different levels of visual awareness influences gaze-induced joint attention. We adopted a spatial-cueing paradigm, in which an averted gaze was used as an uninformative central cue for a joint-attention task. Prior to the onset of the averted-gaze cue, either supraliminal (Experiment 1) or subliminal (Experiment 2) eye contact was presented. The results revealed a larger subsequent gaze-cueing effect following supraliminal eye contact compared to a no-contact condition. In contrast, the gaze-cueing effect was smaller in the subliminal eye-contact condition than in the no-contact condition. These findings suggest that the facilitation effect of eye contact on coordinating social attention depends on visual awareness. Furthermore, subliminal eye contact might have an impact on subsequent social attention processes that differ from supraliminal eye contact. This study highlights the need to further investigate the role of eye contact in implicit social cognition. PMID:29467703
Costa, Marco; Corazza, Leonardo
2006-01-01
In the first study, eye and lip size and roundness, and lower-face roundness were compared between a control sample of 289 photographic portraits and an experimental sample of 776 artistic portraits covering the whole period of the history of art. Results showed that eye roundness, lip roundness, eye height, eye width, and lip height were significantly enhanced in artistic portraits compared to photographic ones. Lip width and lower-face roundness, on the contrary, were less prominent in artistic than in photographic portraits. In a second study, forty-two art academy students were requested to draw two self-portraits, one with a mirror and one without (from memory). Eye, lip, and lower-face roundness in artistic self-portraits was compared to the same features derived from photographic portraits of the participants. The results obtained confirmed those found in the first study. Eye and lip size and roundness were greater in artistic self-portraits, while lower-face roundness was significantly reduced. The same degree of modification was found also when a mirror was available to the subjects. In a third study the effect of lower-face roundness on the perception of attractiveness was assessed: fifty-three participants had to adjust the face width of 24 photographic portraits in order to achieve the highest level of attractiveness. Participants contracted the face width by a mean value of 5.26%, showing a preference for a reduced lower-face roundness. All results are discussed in terms of the importance of the 'supernormalisation' process as a means of assigning aesthetic value to perceptual stimuli.
Characteristics of ocular pain complaints in patients with idiopathic dry eye symptoms
Kalangara, Jerry P.; Galor, Anat; Levitt, Roy C.; Covington, Derek B.; McManus, Katherine T.; Sarantopoulos, Constantine D.; Felix, Elizabeth R.
2016-01-01
Objective The purpose of this study was to examine the severity and quality of ocular pain complaints in patients with dry eye symptoms. Methods Subjects with clinically-relevant dry eye symptoms (dryness, discomfort, tearing) of unknown origin seen in the Miami Veterans Affairs eye clinic were administered questionnaires for dry eye symptoms and ocular pain and underwent a standardized ocular examination. Qualities and severity ratings of ocular pain in subjects with idiopathic dry eye were compared to similar measures from published data in other chronic pain populations. Results The study sample consisted of 154 subjects, of which 91% were male and ranged in age from 27 to 89 (mean age = 61). Fifty-three percent of participants reported an average ocular pain of at least moderate intensity (numerical rating scale (NRS) ≥ 4), with specific characteristics (i.e., “burning” spontaneous pain) reported at frequencies comparable to prevalent chronic neuropathic pain syndromes as reported in the literature. Significant correlations were found between ocular pain metrics and dry eye symptom severity scores (r=0.57 to 0.66). Dry eye signs, however, did not generally correlate with ocular pain severity. Conclusions A significant proportion of subjects with idiopathic dry eye symptoms reported moderate or greater ocular pain intensity, with the majority endorsing descriptors commonly used by patients with non-ocular neuropathic pain conditions. Identifying sub-groups of dry eye patients based on the presence and characteristics of ocular pain complaints may improve dry eye sub classification and better individualize treatment strategies. PMID:26925537
Characteristics of Ocular Pain Complaints in Patients With Idiopathic Dry Eye Symptoms.
Kalangara, Jerry P; Galor, Anat; Levitt, Roy C; Covington, Derek B; McManus, Katherine T; Sarantopoulos, Constantine D; Felix, Elizabeth R
2017-05-01
The purpose of this study was to examine the severity and quality of ocular pain complaints in patients with dry eye symptoms. Subjects with clinically relevant dry eye symptoms (dryness, discomfort, tearing) of unknown origin seen in the Miami Veterans Affairs eye clinic were administered questionnaires for dry eye symptoms and ocular pain and underwent a standardized ocular examination. Qualities and severity ratings of ocular pain in subjects with idiopathic dry eye were compared with similar measures from published data in other chronic pain populations. The study sample consisted of 154 subjects, of which 91% were men and ranged in age from 27 to 89 (mean age=61). Fifty-three percent of participants reported an average ocular pain of at least moderate intensity (numerical rating scale≥4), with specific characteristics (i.e., "burning" spontaneous pain) reported at frequencies comparable to prevalent chronic neuropathic pain syndromes as reported in the literature. Significant correlations were found between ocular pain metrics and dry eye symptom severity scores (r=0.57-0.66). Dry eye signs, however, did not generally correlate with ocular pain severity. A significant proportion of subjects with idiopathic dry eye symptoms reported moderate or greater ocular pain intensity, with most endorsing descriptors commonly used by patients with nonocular neuropathic pain conditions. Identifying subgroups of dry eye patients based on the presence and characteristics of ocular pain complaints may improve dry eye subclassification and better individualize treatment strategies.
One-Step "Change" and "Compare" Word Problems: Focusing on Eye-Movements
ERIC Educational Resources Information Center
Moutsios-Rentzos, Andreas; Stamatis, Panagiotis J.
2015-01-01
Introduction. In this study, we focus on the relationship between the students' mathematical thinking and their non-mechanically identified eye-movements with the purpose to gain deeper understanding about the students' reasoning processes and to investigate the feasibility of incorporating eye-movement information in everyday pedagogy. Method.…
Postoperative refraction in the second eye having cataract surgery.
Leffler, Christopher T; Wilkes, Martin; Reeves, Juliana; Mahmood, Muneera A
2011-01-01
Introduction. Previous cataract surgery studies assumed that first-eye predicted and observed postoperative refractions are equally important for predicting second-eye postoperative refraction. Methods. In a retrospective analysis of 173 patients having bilateral sequential phacoemulsification, multivariable linear regression was used to predict the second-eye postoperative refraction based on refractions predicted by the SRK-T formula for both eyes, the first-eye postoperative refraction, and the difference in IOL selected between eyes. Results. The first-eye observed postoperative refraction was an independent predictor of the second eye postoperative refraction (P < 0.001) and was weighted more heavily than the first-eye predicted refraction. Compared with the SRK-T formula, this model reduced the root-mean-squared (RMS) error of the predicted refraction by 11.3%. Conclusions. The first-eye postoperative refraction is an independent predictor of the second-eye postoperative refraction. The first-eye predicted refraction is less important. These findings may be due to interocular symmetry.
Zhang, Harrison G; Ying, Gui-Shuang
2018-02-09
The aim of this study is to evaluate the current practice of statistical analysis of eye data in clinical science papers published in British Journal of Ophthalmology ( BJO ) and to determine whether the practice of statistical analysis has improved in the past two decades. All clinical science papers (n=125) published in BJO in January-June 2017 were reviewed for their statistical analysis approaches for analysing primary ocular measure. We compared our findings to the results from a previous paper that reviewed BJO papers in 1995. Of 112 papers eligible for analysis, half of the studies analysed the data at an individual level because of the nature of observation, 16 (14%) studies analysed data from one eye only, 36 (32%) studies analysed data from both eyes at ocular level, one study (1%) analysed the overall summary of ocular finding per individual and three (3%) studies used the paired comparison. Among studies with data available from both eyes, 50 (89%) of 56 papers in 2017 did not analyse data from both eyes or ignored the intereye correlation, as compared with in 60 (90%) of 67 papers in 1995 (P=0.96). Among studies that analysed data from both eyes at an ocular level, 33 (92%) of 36 studies completely ignored the intereye correlation in 2017, as compared with in 16 (89%) of 18 studies in 1995 (P=0.40). A majority of studies did not analyse the data properly when data from both eyes were available. The practice of statistical analysis did not improve in the past two decades. Collaborative efforts should be made in the vision research community to improve the practice of statistical analysis for ocular data. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Yang, C-S; Wang, A-G; Shih, Y-F; Hsu, W-M
2013-01-01
Purpose To assess the prevalence of astigmatism and its relationship with biometric optic components in preterm school children with diode laser-treated threshold retinopathy of prematurity (ROP). Methods A prospective, cross-sectional study in which cycloplegic keratometry, refraction, and ultrasound biometric measurement of optic components were performed on 24 consecutive preterm children with diode laser-treated threshold ROP at the age of 9 years. The study results were compared with data on 1021 age-matched full-term control children from a national survey. Results The laser-treated eyes had a mean astigmatism of 3.47 D, with a mean spherical equivalent of −4.49 D. Of the 46 eyes studied, 98% of eyes showed astigmatism ≥0.5 D and 50% had high astigmatism (>3.0 D). Most astigmatic eyes (97.7%) showed with-the-rule astigmatism, with the mean plus cylinder axis at 89.30o. Further correlation analysis showed the astigmatism in refraction was highly correlated with the corneal astigmatism (r=0.921, P<0.001) and the vertical corneal curvature (r=0.405, P=0.005). There was significantly steeper vertical corneal curvature (P=0.003) and flatter horizontal corneal curvature (P=0.031) in eyes with laser-treated ROP when compared with age-matched full-term controls. The eyes with laser-treated ROP also show significantly thicker lens (3.93 mm) and shallower anterior chamber depth (ACD; 2.92 mm) than full-term controls (P<0.001). Conclusions There is significantly higher prevalence and greater magnitude of astigmatism in eyes with laser-treated threshold ROP compared with full-term controls. The steeper vertical corneal curvature component contributes to the increased astigmatism in eyes with laser-treated ROP. PMID:23222565
Effect of Viscous Agents on Corneal Density in Dry Eye Disease.
Wegener, Alfred R; Meyer, Linda M; Schönfeld, Carl-Ludwig
2015-10-01
To investigate the effect of the viscous agents, hydroxypropyl methylcellulose (HPMC), carbomer, povidone, and a combination of HPMC and povidone on corneal density in patients with dry eye disease. In total, 98 eyes of 49 patients suffering from dry eye and 65 eyes of 33 healthy age-matched individuals were included in this prospective, randomized study. Corneal morphology was documented with Scheimpflug photography and corneal density was analyzed in 5 anatomical layers (epithelium, bowman membrane, stroma, descemet's membrane, and endothelium). Corneal density was evaluated for the active ingredients HPMC, carbomer, povidone, and a combination of HPMC and povidone as the viscous agents contained in the artificial tear formulations used by the dry eye patients. Data were compared to the age-matched healthy control group without medication. Corneal density in dry eye patients was reduced in all 5 anatomical layers compared to controls. Corneal density was highest and very close to control in patients treated with HPMC containing ocular lubricants. Patients treated with lubricants, including carbomer as the viscous agent displayed a significant reduction of corneal density in layers 1 and 2 compared to control. HPMC containing ocular lubricants can help to maintain physiological corneal density and may be beneficial in the treatment of dry eye disease.
ERIC Educational Resources Information Center
Bazar, Nancy Sceery
2009-01-01
The purpose of this primarily quantitative study was to compare how young adults with and without intellectual disabilities examine different types of images. Two experiments were conducted. The first, a replication and extension of a classic eye-tracking study (Yarbus, 1967), generated eye gaze patterns and data in response to questions related…
Rein, David B; Wittenborn, John S; Zhang, Xinzhi; Allaire, Benjamin A; Song, Michael S; Klein, Ronald; Saaddine, Jinan B
2011-01-01
Objective To determine whether biennial eye evaluation or telemedicine screening are cost-effective alternatives to current recommendations for the estimated 10 million people aged 30–84 with diabetes but no or minimal diabetic retinopathy. Data Sources United Kingdom Prospective Diabetes Study, National Health and Nutrition Examination Survey, American Academy of Ophthalmology Preferred Practice Patterns, Medicare Payment Schedule. Study Design Cost-effectiveness Monte Carlo simulation. Data Collection/Extraction Methods Literature review, analysis of existing surveys. Principal Findings Biennial eye evaluation was the most cost-effective treatment option when the ability to detect other eye conditions was included in the model. Telemedicine was most cost-effective when other eye conditions were not considered or when telemedicine was assumed to detect refractive error. The current annual eye evaluation recommendation was costly compared with either treatment alternative. Self-referral was most cost-effective up to a willingness to pay (WTP) of U.S.$37,600, with either biennial or annual evaluation most cost-effective at higher WTP levels. Conclusions Annual eye evaluations are costly and add little benefit compared with either plausible alternative. More research on the ability of telemedicine to detect other eye conditions is needed to determine whether it is more cost-effective than biennial eye evaluation. PMID:21492158
Ectopic Six3 expression in the dragon eye goldfish.
Ma, Dong-Mei; Zhu, Hua-Ping; Gui, Jian-Fang
2008-02-01
For goldfish (Carassius auratus), there are many varieties with different eye phenotypes due to artificial selection and adaptive evolution. Dragon eye is a variant eye characterized by a large-size eyeball protruding out of the socket similar to the eye of dragon in Chinese legends. In this study, anatomical structure of the goldfish dragon eye was compared with that of the common eye, and a stretching of the retina was observed in the enlarged dragon eye. Moreover, the homeobox-containing transcription factor Six3 cDNAs were cloned from the two types of goldfish, and the expression patterns were analyzed in both normal eye and dragon eye goldfish. No amino acid sequence differences were observed between the two deduced peptides, and the expression pattern of Six3 protein in dragon eye is quite similar to common eye during embryogenesis, but from 2 days after hatching, ectopic Six3 expression began to occur in the dragon eye, especially in the outer nuclear layer cells. With eye development, more predominant Six3 distribution was detected in the outer nuclear layer cells of dragon eye than that of normal eye, and fewer cell-layers in outer nuclear layer were observed in dragon eye retina than in normal eye retina. The highlight of this study is that higher Six3 expression occurs in dragon eye goldfish than in normal eye goldfish during retinal development of larvae.
Schutte, K; Prinsen, M K; McNamee, P M; Roggeband, R
2009-08-01
Eye irritation is an important endpoint in the safety evaluation of consumer products and their ingredients. Several in vitro methods have been developed and are used by different industry sectors to assess eye irritation. One such in vitro method in use for some time already is the isolated chicken eye test (ICE). This investigation focuses on assessing the ICE as a method to determine the eye irritation potential of household cleaning products, both for product safety assurance prior to marketing and for classification and labeling decisions. The ICE involves a single application of test substances onto the cornea of isolated chicken eyes. Endpoints are corneal swelling, corneal opacity and fluorescein retention. The ICE results were compared to historic LVET data in this study due to availability of such in vivo data and the ability to correlate LVET to human experience data on the outcome of accidental exposures to household cleaning products in general. The results of this study indicate that the ICE test is a useful in vitro method for evaluating the eye irritation/corrosion potential and establishing classification and labeling for household cleaning products. For new product formulations, it is best used as part of a weight-of-evidence approach and benchmarked against data from comparable formulations with known eye irritation/corrosion profiles and market experience.
Rolando, Maurizio; Valente, Cristiana
2007-03-29
One of the problems arising from available preparations for dry eye syndrome is the limited residence time of products on the ocular surface. In this paper, we look at an innovative new treatment for dry eye, tamarind seed polysaccharide (TSP). TSP possesses mucomimetic, mucoadhesive and pseudoplastic properties. The 'mucin-like' molecular structure of TSP is similar to corneal and conjunctival mucin 1 (MUC1), a transmembrane glycoprotein thought to play an essential role in protecting and wetting the corneal surface and may explain its increased retention on the eye surface. The activity of TSP and hyaluronic acid (HA) in the treatment of dry eye syndrome was compared in an open-label, randomised, single-centre clinical study. Thirty patients were randomised to receive three or more applications per day of either TSP 0.5%, TSP 1% or HA 0.2% (Hyalistiltrade mark) over a period of 90 days. The primary objective of tolerability was assessed by visual analogue scale (VAS), scoring of specific symptoms and the incidence of adverse events. Secondary objectives included improvement in stability of the precorneal tear film, subjective symptoms and corneal and conjunctival staining. TSP 0.5% and 1% were comparable to HA 0.2% with regard to both primary and secondary objective parameters.TSP 1% showed benefits over HA 0.2% for the subjective symptoms; trouble blinking, ocular burning and foreign body sensation. This study suggests that TSP 0.5% and 1% offer at least equivalent relief to HA 0.2% for dry eye syndrome. All treatments demonstrated optimal tolerability and are suitable for frequent use in the therapy of dry eye.TSP 1% produced promising results in terms of improvements in certain patient symptoms and suggests benefits of the TSP formulation. This study paves the way for a larger study to further establish the performance and safety of TSP compared with HA and highlights the need to expand this therapeutic agent to a wider dry eye population.
Longitudinal analysis of progression in glaucoma using spectral-domain optical coherence tomography.
Wessel, Julia M; Horn, Folkert K; Tornow, Ralf P; Schmid, Matthias; Mardin, Christian Y; Kruse, Friedrich E; Juenemann, Anselm G; Laemmer, Robert
2013-05-01
To compare the longitudinal loss of RNFL thickness measurements by SD-OCT in healthy individuals and glaucoma patients with or without progression concerning optic disc morphology. A total of 62 eyes, comprising 38 glaucomatous eyes with open angle glaucoma and 24 healthy controls, were included in the study (Erlangen Glaucoma Registry, NTC00494923). All patients were investigated annually over a period of 3 years by Spectralis SD-OCT measuring peripapillary RNFL thickness. By masked comparative analysis of photographs, the eyes were classified into nonprogressive and progressive glaucoma cases. Longitudinal loss of RNFL thickness was compared with morphological changes of optic disc morphology. Mixed model analysis of annual OCT scans revealed an estimated annual decrease of the RNFL thickness by 2.12 μm in glaucoma eyes with progression, whereas glaucoma eyes without progression in optic disc morphology lost 1.18 μm per year in RNFL thickness (P = 0.002). The rate of change in healthy eyes was 0.60 μm and thereby also significantly lower than in glaucoma eyes with progression (P < 0.001). The intrasession variability of three successive measurements without head repositioning was 1.5 ± 0.7 μm. The loss of mean RNFL thickness exceeded the intrasession variability in 60% of nonprogressive eyes, and in 85% of progressive eyes after 3 years. LONGITUDINAL MEASUREMENTS OF RNFL THICKNESS USING SD-OCT SHOW A MORE PRONOUNCED REDUCTION OF RNFL THICKNESS IN PATIENTS WITH PROGRESSION COMPARED WITH PATIENTS WITHOUT PROGRESSION IN GLAUCOMATOUS OPTIC DISC CHANGES. (www.clinicaltrials.gov number, NTC00494923.).
Evaluation of eyes with relative pupillary block by indentation ultrasound biomicroscopy gonioscopy.
Matsunaga, Koichi; Ito, Kunio; Esaki, Koji; Sugimoto, Kota; Sano, Toru; Miura, Katsuya; Sasoh, Mikio; Uji, Yukitaka
2004-03-01
To investigate changes in anterior chamber angle configuration with indentation ultrasound biomicroscopy gonioscopy of relative pupillary block (RPB). Cross-sectional study. This study included 26 eyes of 26 patients with RPB. We determined angle opening distance 500 and angle recess area using indentation ultrasound biomicroscopy gonioscopy and compared a small-sized standard eye cup with a new eye cup with an area for inducing pressure. Indentation ultrasound biomicroscopy images documented concavity of the iris in eyes with RPB. Both the new and the small standard eye cups widened the anterior chamber angle significantly (P <.0001) without causing corneal damage. Angle changes were significantly greater for the new eye cup design. Indentation ultrasound biomicroscopy gonioscopy is a useful technique for observation and diagnosis of RPB. Using a small standard or the newly designed eye cup, the procedure can be performed easily and without causing corneal damage.
The Prevalence of Dry Eye and Sjögren Syndrome in Patients with Migraine.
Sarac, Ozge; Kosekahya, Pinar; Yildiz Tasci, Yelda; Keklikoglu, Hava D; Deniz, Orhan; Erten, Şükran; Çağıl, Nurullah
2017-06-01
To evaluate the presence of dry eye and primary Sjögren syndrome (SS) in patients with migraine. In total, 46 eyes of 46 patients with migraine (group 1) and 50 eyes of 50 healthy subjects (group 2) were included in this study. Detailed ophthalmologic, neurologic and rheumatologic examination were performed on all participants. Ocular surface disease index questionnaire, tear function tests, visual analog scale for pain, serologic analysis were also performed. Dry eye symptoms and findings were significantly higher and more severe in group 1 when compared with group 2. Primary SS was not found in any of the participants. The migraine lifetime duration was negatively correlated with the tear function tests while it was positively correlated with the ocular surface disease index scores. Dry eye symptoms and findings are higher in migraine patients when compared with the healthy subjects without the presence of Sjögren syndrome.
Jørstad, Øystein Kalsnes; Faber, Rowan Thomas; Moe, Morten Carstens
2017-08-01
To study the effects of converting to aflibercept in accordance with a treat and extend (T&E) strategy in eyes with treatment resistant exudative age-related macular degeneration (AMD). Two-year prospective study of eyes with exudative AMD and persistent macular fluid despite monthly treatment with ranibizumab or bevacizumab. Eyes were converted to 2.0 mg aflibercept in accordance with a T&E protocol. Fifty eyes from 47 patients were included. At baseline, the mean central retinal thickness (CRT) was 273 μm and mean best-corrected visual acuity (BCVA) 0.25 logarithm of the minimal angle of resolution (logMAR). The mean number of aflibercept injections the first year was 9.2. After 1 year, there was a reduction in mean CRT to 228 μm (p < 0.001); 22 eyes (44%) had a dry macula; and the mean BCVA was 0.24 logMAR (p = 0.531). The mean number of aflibercept injections the second year was 8.0 (p = 0.013 compared to first year). After 2 years, 24 eyes (48%) received treatment more frequently than every eighth week. The mean CRT was 225 μm (p < 0.001 compared to baseline); 31 eyes (62%) had a dry macula; and mean BCVA was 0.32 logMAR (p = 0.005 compared to baseline). Five eyes did not complete 2 years of aflibercept treatment after failing to improve. A majority of eyes showed improved anatomic outcomes. There was a small decrease in mean BCVA after the second year of treatment. About half of the eyes required treatment more frequently than the recommended aflibercept label of an 8-week interval. © 2017 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Power, S; Mirza, M; Thakorlal, A; Ganai, B; Gavagan, L D; Given, M F; Lee, M J
2015-06-01
This prospective pilot study was undertaken to evaluate the feasibility and effectiveness of using a radiation absorbing shield to reduce operator dose from scatter during lower limb endovascular procedures. A commercially available bismuth shield system (RADPAD) was used. Sixty consecutive patients undergoing lower limb angioplasty were included. Thirty procedures were performed without the RADPAD (control group) and thirty with the RADPAD (study group). Two separate methods were used to measure dose to a single operator. Thermoluminescent dosimeter (TLD) badges were used to measure hand, eye, and unshielded body dose. A direct dosimeter with digital readout was also used to measure eye and unshielded body dose. To allow for variation between control and study groups, dose per unit time was calculated. TLD results demonstrated a significant reduction in median body dose per unit time for the study group compared with controls (p = 0.001), corresponding to a mean dose reduction rate of 65 %. Median eye and hand dose per unit time were also reduced in the study group compared with control group, however, this was not statistically significant (p = 0.081 for eye, p = 0.628 for hand). Direct dosimeter readings also showed statistically significant reduction in median unshielded body dose rate for the study group compared with controls (p = 0.037). Eye dose rate was reduced for the study group but this was not statistically significant (p = 0.142). Initial results are encouraging. Use of the shield resulted in a statistically significant reduction in unshielded dose to the operator's body. Measured dose to the eye and hand of operator were also reduced but did not reach statistical significance in this pilot study.
Yılmaz, Uğur; Küçük, Erkut; Koç, Çağdaş; Gökler, Enes
2017-06-01
To investigate dry eye development in the patients receiving systemic retinoic acid therapy and to compare effectiveness of Autologous Serum (AS) and preservative free artificial tear (PFAT) in the patients with dry eye disease. This prospective, crossover, double blind study was conducted on patients who have dry eyes due to systemic isotretinoin treatment for different indications. Patients detected as having dry eye during systemic isotretinoin treatment were included to our study. At baseline, 1 and 2 month of study, detailed ocular examination, best corrected visual acuity measurement, intraocular pressure measurement, and Tear Break-up Time (TBUT) and Schirmer Test (ST) without topical anesthesia were performed. We compared the efficacy of AS and PFAT. To accomplish crossover after the first month, treatment given to each patient was switched to the other treatment. Statistical analysis was measured using SPSS version 20.0. p values of < 0.05 were considered as statistically significant. At the end of the first month, there was a significant improvement for the TBUT test in both AS and PFAT groups compared to baseline (respectively p < 0.001, p < 0.001). TBUT was found to be significantly higher in the AS group compared to the PFAT group at the end of the first month (p < 0.001). At the end of the second month, TBUT was found to be significantly higher in the AS group compared to the PFAT group at the posttreatment time (p < 0.001). There was a significant OSDI score decreasing in both groups compared to that reported previously at the end of the first and second months (respectively p < 0.001, p < 0.001). OSDI score decreasing was more significant in the AS group compared to the PFAT group at both time points (respectively p < 0.001, p < 0.001). AS may be an effective alternative to PFAT in the treatment of dry eye developed during isotretinoin use.
Petrov, Anton; Perekhvatova, Natalia; Skulachev, Maxim; Stein, Linda; Ousler, George
2016-01-01
This Phase 2 clinical trial assessed the efficacy and safety of the novel antioxidative, renewable compound SkQ1 for topical treatment of dry eye signs and symptoms. In a single-center, randomized, double-masked, placebo-controlled, 29-day study, 91 subjects with mild to moderate dry eye instilled the study drug twice daily and recorded dry eye symptoms daily. Subjects were randomized 1:1:1 into one of three ophthalmic solution treatment groups: SkQ1 1.55 µg/mL, SkQ1 0.155 µg/mL, or 0.0 µg/mL (placebo). Subjects were exposed to a controlled adverse environment chamber at 3 of the 4 study visits (Day -7, Day 1, and Day 29). Investigator assessments occurred at all study visits. SkQ1 was safe and efficacious in treating dry eye signs and symptoms. Statistically significant improvements with SkQ1 compared to placebo occurred for the dry eye signs of corneal fluorescein staining and lissamine green staining in the central region and lid margin redness, and for the dry eye symptoms of ocular discomfort, dryness, and grittiness. In addition, SkQ1 demonstrated greater efficacy compared to placebo, although the differences were not statistically significant, for corneal fluorescein staining in other regions and/or time points (total staining score, central region, corneal sum score, and temporal region), lissamine green staining for the central and nasal regions, and blink rate scores. This Phase 2 study indicated that SkQ1 is safe and efficacious for the treatment of dry eye signs and symptoms and supported previous study results. Clinicaltrials.gov identifier: NCT02121301. Miotech S.A.
Cennamo, Gilda; Forte, Raimondo; Aufiero, Bernardino; La Rana, Agostino
2011-08-01
To evaluate changes in anterior corneal optical density and the refractive index after photorefractive keratectomy (PRK) using a rotating Scheimpflug system. Department of Ophthalmology, University Federico II, Naples, Italy. Comparative case series. Anterior corneal optical density was evaluated with a rotating Scheimpflug system at baseline and 3 months and 12 months after PRK in eyes with a refractive error between -6.00 diopters (D) and -12.00 D (study group). A control group of unoperated eyes with the same refraction range was used to calculate corneal optical density and the Gladstone-Dale constant in unoperated eyes using the Gladstone-Dale formula. In the study group, changes in the anterior corneal optical density were evaluated over time and variations in the anterior corneal refractive index were obtained using the Gladstone-Dale constant. The study group comprised 37 eyes and the control group, 200 eyes. In the study group, the mean anterior corneal optical density and refractive index, respectively, were 27.71 ± 4.39 and 1.360 ± 0.05 at baseline, 37.812 ± 12.31 and 1.491 ± 0.16 after 3 months (P<.001 compared with baseline), and 26.29 ± 4.93 and 1.341 ± 0.06 after 12 months (P=.03 compared with baseline). The mean corneal optical density in the control group was 27.71 ± 4.31 (SD), and the resultant Gladstone-Dale constant was 0.013. An early increase and a subsequent reduction in anterior corneal optical density and the refractive index were present in myopic eyes during 1 year after PRK. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Tan, J S P; Tan, K-L; Lee, J C L; Wan, C-M; Leong, J-L; Chan, L-L
2009-02-01
To our knowledge, there has been no study that compares the radiation dose delivered to the eye lens by 16- and 64-section multidetector CT (MDCT) for standard clinical neuroimaging protocols. Our aim was to assess radiation-dose differences between 16- and 64-section MDCT from the same manufacturer, by using near-identical neuroimaging protocols. Three cadaveric heads were scanned on 16- and 64-section MDCT by using standard neuroimaging CT protocols. Eye lens dose was measured by using thermoluminescent dosimeters (TLD), and each scanning was repeated to reduce random error. The dose-length product, volume CT dose index (CTDI(vol)), and TLD readings for each imaging protocol were averaged and compared between scanners and protocols, by using the paired Student t test. Statistical significance was defined at P < .05. The radiation dose delivered and eye lens doses were lower by 28.1%-45.7% (P < .000) on the 64-section MDCT for near-identical imaging protocols. On the 16-section MDCT, lens dose reduction was greatest (81.1%) on a tilted axial mode, compared with a nontilted helical mode for CT brain scans. Among the protocols studied, CT of the temporal bone delivered the greatest radiation dose to the eye lens. Eye lens radiation doses delivered by the 64-section MDCT are significantly lower, partly due to improvements in automatic tube current modulation technology. However, where applicable, protection of the eyes from the radiation beam by either repositioning the head or tilting the gantry remains the best way to reduce eye lens dose.
Bhandary, Sulatha; Khanna, Rajesh; Rao, Krishna A; Rao, Lavanya G; Lingam, Kamala D; Binu, V
2011-01-01
Corneal blindness accounts for 3.42% of blindness in Malaysia; the rate of eye donation is low. The aim of the study was to assess the awareness about eye donation and willingness to donate eyes among attendants of patients at various clinics in Melaka, Malaysia. This observational study was conducted on attendants who accompanied patients (n = 400) visiting various outpatient departments of the General Hospital and two peripheral clinics in Melaka between August and October 2007. The participants answered a questionnaire (Malay and English versions) which included demographic profile, awareness of eye donation, knowledge regarding facts of eye donation, and willingness to donate eyes. Univariate and multivariate logistic regression was performed at 5% level of significance. Awareness of eye donation was observed in 276 (69%) participants. Multivariate analysis showed that awareness was more among females when compared to males (P = 0.009). Of the 276 participants who were aware of eye donation, only 34.42% were willing to donate eyes. Willingness was more among the Indian race (P = 0.02) and males (P = 0.02). Educational status did not influence the willingness to donate eyes. Although majority of participants were aware of eye donation, willingness to donate eyes was poor.
Allometry indicates giant eyes of giant squid are not exceptional.
Schmitz, Lars; Motani, Ryosuke; Oufiero, Christopher E; Martin, Christopher H; McGee, Matthew D; Gamarra, Ashlee R; Lee, Johanna J; Wainwright, Peter C
2013-02-18
The eyes of giant and colossal squid are among the largest eyes in the history of life. It was recently proposed that sperm whale predation is the main driver of eye size evolution in giant squid, on the basis of an optical model that suggested optimal performance in detecting large luminous visual targets such as whales in the deep sea. However, it is poorly understood how the eye size of giant and colossal squid compares to that of other aquatic organisms when scaling effects are considered. We performed a large-scale comparative study that included 87 squid species and 237 species of acanthomorph fish. While squid have larger eyes than most acanthomorphs, a comparison of relative eye size among squid suggests that giant and colossal squid do not have unusually large eyes. After revising constants used in a previous model we found that large eyes perform equally well in detecting point targets and large luminous targets in the deep sea. The eyes of giant and colossal squid do not appear exceptionally large when allometric effects are considered. It is probable that the giant eyes of giant squid result from a phylogenetically conserved developmental pattern manifested in very large animals. Whatever the cause of large eyes, they appear to have several advantages for vision in the reduced light of the deep mesopelagic zone.
Precision Pulse Capsulotomy: Preclinical Safety and Performance of a New Capsulotomy Technology.
Chang, David F; Mamalis, Nick; Werner, Liliana
2016-02-01
To assess the preclinical safety and performance of a new precision pulse capsulotomy (PPC) method. Human cadaver eye studies and surgical, slit-lamp, and histopathologic evaluation in a consecutive series of 20 live rabbits. Human cadaver eyes and New Zealand white rabbits. Precision pulse capsulotomy uses a highly focused, fast, multipulse, low-energy discharge to produce a perfectly round anterior capsulotomy instantaneously and simultaneously along all 360°. Capsulotomies are performed using a disposable handpiece with a soft collapsible tip and circular nitinol cutting element. Miyake-Apple imaging and scanning electron microscopy (SEM) of PPC were conducted in human cadaver eyes. Surgical, postoperative slit-lamp, and histopathologic assessments of PPC were performed in 20 live rabbits and were compared with manual continuous curvilinear capsulorrhexis (CCC) in the fellow eye. Anterior chamber (AC) thermocouple temperature measurements were evaluated in a subset of rabbit eyes. Capsulotomy edge circularity, SEM morphologic features and zonular movement with PPC in human cadaver eyes. Anterior chamber temperature during PPC and grading of ocular inflammation, corneal endothelial damage, anterior capsular opacification (ACO), and posterior capsular opacification (PCO). Miyake-Apple imaging showed minimal zonular stress, and thermocouple measurements demonstrated negligible AC temperature changes during PPC. Precision pulse capsulotomy produced round, complete capsulotomies in all 20 rabbit eyes, leading to successful in-the-bag intraocular lens (IOL) implantation. Slit-lamp examinations at 3 days and 1, 2, and 4 weeks after surgery showed no significant differences between PPC and CCC in corneal edema, AC inflammatory reaction, capsular fibrosis, ACO, and PCO. Postmortem studies showed no difference in the corneal endothelium between PPC and CCC eyes. All IOLs were well centered in PPC eyes, and histopathologic analysis showed no greater inflammatory infiltrates. Precision pulse capsulotomy is a new method to automate consistent creation of a perfectly circular anterior capsulotomy with a disposable handheld instrument that can be used in the normal phacoemulsification surgical sequence. Compared with CCC in fellow rabbit eyes, PPC was equally safe and showed no greater zonular stress compared with CCC in human cadaver eyes. Human cadaver eye SEM showed a much smoother capsulotomy edge compared to those produced by femtosecond laser. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Corneal thickness of eyes with unilateral age-related macular degeneration.
Arikan, Sedat; Ersan, Ismail; Kara, Selcuk; Gencer, Baran; Korkmaz, Safak; Vural, Azer Sara
2015-01-01
To compare the central corneal thicknesses (CCT), peripheral corneal thicknesses, and corneal volumes (CV) of the 2 eyes of patients with unilateral age-related macular degeneration (AMD). Twenty patients who were diagnosed with unilateral AMD were included in this prospective study for the purpose of making comparison between the diseased and healthy eyes. Optical coherence tomography and fundus fluorescein angiography imaging were applied to all patients in order to confirm and reveal the presence of unilateral AMD. Then, the measurements of CCT, peripheral corneal thickness measured 4 mm distant from the center of the cornea (4 mm CT), and CV of each eye of these patients were obtained through the rotating Scheimpflug corneal topographer. Wilcoxon signed-rank test did not demonstrate a statistically significant difference between the 2 eyes of patients with unilateral AMD when we compared the CCT and CV of diseased and healthy eyes (p>0.05). However, 4 mm CT of the diseased eyes of these patients were statistically significantly thicker than the healthy eyes (p<0.05). The significant difference in terms of 4 mm CT between the diseased and healthy eyes of patients with unilateral AMD may demonstrate the possible effect of peripheral corneal thickness on the development of AMD.
Parihar, Jitendra Kumar Singh; Jain, Vaibhav Kumar; Kaushik, Jaya; Mishra, Avinash
2017-03-01
To compare the outcome of pars-plana-modified Ahmed glaucoma valve (AGV) versus limbal-based conventional AGV into the anterior chamber, in patients undergoing penetrating keratoplasty (PK) for glaucoma with coexisting corneal diseases. In this prospective randomized clinical trial, 58 eyes of 58 patients with glaucoma and coexisting corneal disease were divided into two groups. Group 1 (29 eyes of 29 patients) included patients undergoing limbal-based conventional AGV into the anterior chamber (AC) along-with PK and group 2 (29 eyes of 29 patients) included those undergoing pars-plana-modified AGV along-with PK. Outcome measures included corneal graft clarity, intraocular pressure (IOP), number of antiglaucoma medications, and postoperative complications. Patients were followed up for a minimum period of 2 years. Out of 58 eyes (58 patients), 50 eyes (50 patients: 25 eyes of 25 patients each in group 1 and group 2) completed the study and were analyzed. Complete success rate for AGV (group 1: 76%; group 2: 72%; p = 0.842) and corneal graft clarity (group 1: 68%; group 2: 76%; p = 0.081) were comparable between the two groups at 2 years. Graft failure was more in conventional AGV (32%) as compared to pars plana-modified AGV (24%) but not statistically significant (p = 0.078) at 2 years. Though both procedures were comparable in various outcome measures, pars-plana-modified AGV is a viable option for patients undergoing PK, as it provides a relatively better corneal graft survival rate and lesser complications that were associated with conventional AGV.
ERIC Educational Resources Information Center
Edmunds, Sarah R.; Rozga, Agata; Li, Yin; Karp, Elizabeth A.; Ibanez, Lisa V.; Rehg, James M.; Stone, Wendy L.
2017-01-01
Children with autism spectrum disorder (ASD) show reduced gaze to social partners. Eye contact during live interactions is often measured using stationary cameras that capture various views of the child, but determining a child's precise gaze target within another's face is nearly impossible. This study compared eye gaze coding derived from…
Mudhol, Rekha R; Zingade, N D; Mudhol, R S; Harugop, Anil S; Das, Amal T
2013-08-01
The aim of the study is to compare the subjective (relief of symptoms) and objective (endoscopic visualization of ostium patency at the time of syringing) outcomes at the end of two procedures-Endonasal DCR versus External DCR with Mitomycin C and to assess the role of Mitomycin C in maintaining patency of nasolacrimal drainage system. Prospective randomized comparative study was performed. Thirty-five patients were enrolled in each endoscopic and external dacryocystorhinostomy groups with Mitomycin C (MMC) application. The 37 eyes underwent endonasal DCR (28 unilateral primary eyes + 1 bilateral primary eyes + 5 unilateral revision eyes + 1 bilateral revision eye) while 35 eyes underwent external DCR (34 unilateral primary eyes + 1 unilateral revision eye). Mitomycin C 0.2 mg/ml was applied intra-operatively for 5 min to the ostium site at the end of endonasal or external DCR procedure. Objective assessment by syringing at the end of 1 year in the endonasal group showed 35 eyes (94%) were patent, 1 (3%) was partially blocked and 1(3%) was completely blocked; while in external group all 35 eyes (100%) were patent. Endoscopic visualization of the ostium at the time of syringing showed only one eye (3%) in the endonasal group was blocked while all the other eyes in both groups were patent. Both groups had a mean follow-up of 6-36 months. No complications were associated with use of Mitomycin C. In conclusion, intra-operative use of Mitomycin C in both endoscopic DCR and external DCR is safe and effective in increasing the success rate.
Use of EyeCam for imaging the anterior chamber angle.
Perera, Shamira A; Baskaran, Mani; Friedman, David S; Tun, Tin A; Htoon, Hla M; Kumar, Rajesh S; Aung, Tin
2010-06-01
To compare EyeCam (Clarity Medical Systems, Pleasanton, CA) imaging with gonioscopy for detecting angle closure. In this prospective, hospital-based study, subjects underwent gonioscopy by a single observer and EyeCam imaging by a different operator. EyeCam images were graded by two masked observers. The anterior chamber angle in a quadrant was classified as closed if the trabecular meshwork could not be seen. The eye was classified as having angle closure if two or more quadrants were closed. One hundred fifty-two subjects were studied. The mean age was 57.4 years (SD 12.9) and there were 82 (54%) men. Of the 152 eyes, 21 (13.8%) had angle closure. The EyeCam provided clear images of the angles in 98.8% of subjects. The agreement between the EyeCam and gonioscopy for detecting angle closure in the superior, inferior, nasal, and temporal quadrants based on agreement coefficient (AC1) statistics was 0.73, 0.75, 0.76, and 0.72, respectively. EyeCam detected more closed angles than did gonioscopy in all quadrants (P < 0.05). With gonioscopy, 21/152 (13.8%) eyes were diagnosed as angle closure compared to 41 (27.0%) of 152 with EyeCam (P < 0.001, McNemar Test), giving an overall sensitivity of 76.2% (95% confidence interval [CI], 54.9%-90.7%), specificity of 80.9% (95%CI, 73.5%-87.3%), and an area under the receiver operating characteristic curve (AUC) of 0.79. The EyeCam showed good agreement with gonioscopy for detecting angle closure. However, it detected more closed angles than did gonioscopy in all quadrants.
Kozak, Igor; Vaidya, Vijay; Van Natta, Mark L.; Pak, Jeong W.; May, K. Patrick; Thorne, Jennifer E.
2014-01-01
Purpose. To determine the prevalence and incidence of epiretinal membranes (ERM) in eyes with inactive extramacular cytomegalovirus (CMV) retinitis in patients with acquired immune deficiency syndrome (AIDS). Methods. A case–control report from a longitudinal multicenter observational study by the Studies of the Ocular Complications of AIDS (SOCA) Research Group. A total of 357 eyes of 270 patients with inactive CMV retinitis and 1084 eyes of 552 patients with no ocular opportunistic infection (OOI) were studied. Stereoscopic views of the posterior pole from fundus photographs were assessed at baseline and year 5 visits for the presence of macular ERM. Generalized estimating equations (GEE) logistic regression was used to compare the prevalence and 5-year incidence of ERM in eyes with and without CMV retinitis at enrollment. Crude and adjusted logistic regression was performed adjusting for possible confounders. Main outcome measures included the prevalence, incidence, estimated prevalence, and incidence odds ratios. Results. The prevalence of ERM at enrollment was 14.8% (53/357) in eyes with CMV retinitis versus 1.8% (19/1084) in eyes with no OOI. The incidence of ERM at 5 years was 18.6% (16/86) in eyes with CMV retinitis versus 2.4% (6/253) in eyes with no OOI. The crude odds ratio (OR) (95% confidence interval, CI) for prevalence was 9.8 (5.5–17.5) (P < 0.01). The crude OR (95% CI) for incidence was 9.4 (3.2–27.9) (P < 0.01). Conclusions. A history of extramacular CMV retinitis is associated with increased prevalence and incidence of ERM formation compared to what is seen in eyes without ocular opportunistic infections in AIDS patients. PMID:24925880
Kozak, Igor; Vaidya, Vijay; Van Natta, Mark L; Pak, Jeong W; May, K Patrick; Thorne, Jennifer E
2014-06-12
To determine the prevalence and incidence of epiretinal membranes (ERM) in eyes with inactive extramacular cytomegalovirus (CMV) retinitis in patients with acquired immune deficiency syndrome (AIDS). A case-control report from a longitudinal multicenter observational study by the Studies of the Ocular Complications of AIDS (SOCA) Research Group. A total of 357 eyes of 270 patients with inactive CMV retinitis and 1084 eyes of 552 patients with no ocular opportunistic infection (OOI) were studied. Stereoscopic views of the posterior pole from fundus photographs were assessed at baseline and year 5 visits for the presence of macular ERM. Generalized estimating equations (GEE) logistic regression was used to compare the prevalence and 5-year incidence of ERM in eyes with and without CMV retinitis at enrollment. Crude and adjusted logistic regression was performed adjusting for possible confounders. Main outcome measures included the prevalence, incidence, estimated prevalence, and incidence odds ratios. The prevalence of ERM at enrollment was 14.8% (53/357) in eyes with CMV retinitis versus 1.8% (19/1084) in eyes with no OOI. The incidence of ERM at 5 years was 18.6% (16/86) in eyes with CMV retinitis versus 2.4% (6/253) in eyes with no OOI. The crude odds ratio (OR) (95% confidence interval, CI) for prevalence was 9.8 (5.5-17.5) (P < 0.01). The crude OR (95% CI) for incidence was 9.4 (3.2-27.9) (P < 0.01). A history of extramacular CMV retinitis is associated with increased prevalence and incidence of ERM formation compared to what is seen in eyes without ocular opportunistic infections in AIDS patients. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.
Biometric and structural ocular manifestations of Marfan syndrome.
Gehle, Petra; Goergen, Barbara; Pilger, Daniel; Ruokonen, Peter; Robinson, Peter N; Salchow, Daniel J
2017-01-01
To study biometric and structural ocular manifestations of Marfan syndrome (MFS). Observational, retrospective, comparative cohort study in a tertiary referral center on 285 MFS patients and 267 controls. Structural and biometric ocular characteristic were compared. MFS eyes were longer (axial length 24.25 ± 1.74 mm versus 23.89 ± 1.31 mm, p < 0.001) and had a flatter cornea than control eyes (mean keratometry 41.78 ± 1.80 diopters (D) versus 43.05 ± 1.51 D, p < 0.001). Corneal astigmatism was greater and the central cornea was thinner in MFS eyes (530.14 ± 41.31 μm versus 547.02 ± 39.18 μm, p < 0.001). MFS eyes were more myopic than control eyes (spherical equivalent -2.16 ± 3.75 D versus -1.17 ± 2.58 D, p < 0.001). Visual acuity was reduced (0.13 ± 0.25 logMAR versus 0.05 ± 0.18 logMAR, p < 0.001) and intraocular pressure was lower in MFS eyes (14.6 ± 3.4 mmHg versus 15.1 ± 3.2 mmHg, p = 0.01). Iris transillumination defects (ITD) were significantly more common in MFS eyes (odds ratio for MFS in the presence of ITD, 3.7). Ectopia lentis (EL) was only present in MFS eyes (33.4%). History of retinal detachment was significantly more common in MFS eyes. Glaucoma was equally common in both groups. ITD and EL are most characteristic findings in MFS. ITD and corneal curvature should be studied as diagnostic criteria for MFS. Visual acuity is reduced in MFS. MFS patients need regular eye exams to identify serious ocular complications.
Biometric and structural ocular manifestations of Marfan syndrome
Gehle, Petra; Goergen, Barbara; Pilger, Daniel; Ruokonen, Peter; Robinson, Peter N.
2017-01-01
Background To study biometric and structural ocular manifestations of Marfan syndrome (MFS). Methods Observational, retrospective, comparative cohort study in a tertiary referral center on 285 MFS patients and 267 controls. Structural and biometric ocular characteristic were compared. Results MFS eyes were longer (axial length 24.25 ± 1.74 mm versus 23.89 ± 1.31 mm, p < 0.001) and had a flatter cornea than control eyes (mean keratometry 41.78 ± 1.80 diopters (D) versus 43.05 ± 1.51 D, p < 0.001). Corneal astigmatism was greater and the central cornea was thinner in MFS eyes (530.14 ± 41.31 μm versus 547.02 ± 39.18 μm, p < 0.001). MFS eyes were more myopic than control eyes (spherical equivalent -2.16 ± 3.75 D versus -1.17 ± 2.58 D, p < 0.001). Visual acuity was reduced (0.13 ± 0.25 logMAR versus 0.05 ± 0.18 logMAR, p < 0.001) and intraocular pressure was lower in MFS eyes (14.6 ± 3.4 mmHg versus 15.1 ± 3.2 mmHg, p = 0.01). Iris transillumination defects (ITD) were significantly more common in MFS eyes (odds ratio for MFS in the presence of ITD, 3.7). Ectopia lentis (EL) was only present in MFS eyes (33.4%). History of retinal detachment was significantly more common in MFS eyes. Glaucoma was equally common in both groups. Conclusions ITD and EL are most characteristic findings in MFS. ITD and corneal curvature should be studied as diagnostic criteria for MFS. Visual acuity is reduced in MFS. MFS patients need regular eye exams to identify serious ocular complications. PMID:28931008
Corneal status in primary angle-closure glaucoma with a history of acute attack.
Chen, Mei-Ju; Liu, Catherine Jui-Ling; Cheng, Ching-Yu; Lee, Shui-Mei
2012-01-01
The corneal status of patients with primary angle-closure glaucoma (PACG) with a history of acute attack was investigated. This cross-sectional study included 40 eyes of PACG patients with an earlier documented symptomatic acute angle-closure attack (aPACG), 40 uninvolved fellow eyes of aPACG patients (fPACG), 44 eyes of chronic PACG patients without such a history (cPACG), and 50 eyes of age-matched normal participants. All glaucoma patients had patent peripheral iridotomies with adequate intraocular pressure control. The examinations and recorded parameters included visual acuity, intraocular pressure, gonioscopy, vertical cup-to-disc ratio, specular microscopy, central corneal pachymetry, refraction, corneal curvature radius, anterior chamber depth, axial length, and lens thickness measurements, and the presenting intraocular pressure and the duration of acute angle-closure attack for aPACG eyes. The mean endothelial cell density was 2271±80 cells/mm(2) in aPACG, 2458±79 cells/mm(2) in fPACG, 2379±50 cells/mm(2) in cPACG, and 2559±45 cells/mm(2) in controls. The aPACG eyes had significantly lower endothelial cell density compared with normal eyes (P=0.002). There was no significant difference in endothelial cell density of aPACG eyes compared with fPACG or cPACG eyes. Multivariate analysis showed the duration of the acute attack was the only factor independently associated with corneal endothelial density of aPACG eyes. The mean central corneal thickness of aPACG (549±32 μm) did not differ significantly from control eyes (552±27 μm), cPACG (557±32 μm), and fPACG (553±31 μm) (P=0.911, 0.274, and 0.725, respectively). Corneal curvature radius of aPACG eyes was not significantly different from that of the comparison groups (all P>0.05). Corneal endothelial cell density was significantly reduced in aPACG eyes compared with normal eyes. No significant difference in endothelial cell density of aPACG eyes was noted when compared with fPACG or cPACG eyes. Corneal endothelial cell density was negatively associated with the duration of the acute attack, but was not associated with demographic and biometric characteristics. Central corneal thickness and corneal curvature radius were not associated with an earlier acute angle-closure attack.
Eye Movements and Overt Rehearsal in Word Recall
ERIC Educational Resources Information Center
Geiselman, Ralph E.; Bellezza, Francis S.
1977-01-01
Rates of overt rehearsal and eye movement were compared to each other, and were also compared as predictors of immediate and delayed recall. Concludes that total looking time was the best predictor of long-term retention and that recall performance following overt rehearsal was different from recall performance following silent study. (Editor/RK)
Asena, Bilgehan Sezgin; Kaskaloglu, Mahmut
2016-08-01
This study aims to compare the efficacy and safety of femtosecond (FS) laser capsulotomy between mature and non-mature cataracts. Kaskaloglu Eye Hospital, single center study. Prospective, controlled, and masked cross-sectional disease. A total of 133 eyes of 97 patients were included in this study. The Lens Opacities Classification System III grading scale was used in order to classify cataracts into two groups: mature and non-mature. The LenSx laser system (Alcon Labs Inc, Fort Worth, TX) was used. Data were extracted from patient charts, which included cataract grading, capsulotomy problems (tag, incomplete capsulotomy, and anterior capsule tears). The mean age was 69.2 ± 10 years (64 males, 34 females). There were 50 eyes in Group I and 83 eyes in Group II. In 20 out of 133 eyes (15%) capsule tags occurred. Of these 20 eyes, 12 were in Group I, and 8 were in Group II. The number of tag occurrences was statistically higher in Group I when compared to Group II (P = 0.011). Incomplete capsulotomy was significantly higher in Group I when compared to Group II (P < 0.0001). Free capsulotomy was present in 36 out of 50 eyes (72%) in Group I and 75 out of 83 eyes (90%) in Group II (P = 0.03). The grade of cataract significantly increased the number of suboptimal capsulotomy outcomes in FS laser capsulotomy. In mature cataract cases, the surgeon should be aware of limitations of FS laser in order to prevent capsule-related complications. Further studies of the relationship between pulse energy, patient interface design, and capsule burst strength will help elucidate the optimum parameters for laser capsulotomy creation in mature cataracts. Lasers Surg. Med. 48:590-595, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
[Occurrence of various immunoglobulin isotopes in horses with equine recurrent uveitis (ERU)].
Eule, J C; Wagner, B; Leibold, W; Deegen, E
2000-06-01
We investigated 30 healthy eyes and 41 eyes with ERU from 57 horses. The total immunoglobulin titers and titers of IgGa, IgGb, IgM were measured in aqueous humour, vitreous and serum using different ELISA techniques. Every sample investigated contained detectable amounts of immunoglobulins. Compared to control eyes significantly increased titers were found in the aqueous humour and vitreous of the ERU eyes for all immunoglobulin isotypes studied (p < or = 0.01). While IgM was detected in only 2 out of thirty aqueous humour and in none of the thirty vitreous samples of healthy eyes, 79.6% of samples of ERU eyes revealed considerable IgM titers. Changes of the IgGa/IgGb ratio in the eye as compared to that in the autologous serum was more frequent in affected than in healthy eyes. In contrast to the intraocular immunoglobulins there were no significant differences in immunoglobulin serum titers in healthy horses and those affected with ERU (p > 0.05). In conclusion, the results argue for a physiological appearance of immunoglobulins in the healthy eye. The increased titers of immunoglobulins in eyes stricken with ERU might be signs either of a local ocular production of antibodies and/or an increased permeability of intraocular barriers.
Regression of early diabetic macular oedema is associated with prevention of dark adaptation
Arden, G B; Jyothi, S; Hogg, C H; Lee, Y F; Sivaprasad, S
2011-01-01
Hypothesis Dark-adapted rods consume oxygen at high rates and light adaptation decreases this oxygen burden and can have therapeutic effects on diabetic macular oedema (DMO). Methods Patients with mild non-proliferative diabetic retinopathy (DR) and early, untreated non-sight-threatening DMO slept for 6 months wearing masks that illuminated the eyelid of one closed eye by 505 nm light. Exclusion criteria were any concomitant eye disease, DR >ETDRS grade 35, and other systemic diseases. Primary outcome: change of OCT retinal thickness in the local region where oedema was present. Results A total of 34 out of 40 patients completed the study. Mean baseline OCT macular cube thickness was equivalent for study and fellow eyes. But study eyes had a greater mean thickness in the central subfield zone 1 (282±53 μm) vs (256±19 μm) the fellow eyes. Twenty-eight study eyes showed intraretinal cysts compared with nine in the fellow eyes. At 6 months, only 19 study eyes had cysts while cysts were seen in 20 fellow eyes. After 6 months, the worst affected ETDRS zone and the central subfield zone 1 reduced in thickness in study eyes only by 12 μm (95% CI 20 to −7, P=0.01). The secondary outcomes of change in visual acuity, achromatic contrast sensitivity, and microperimetric thresholds improved significantly in study eyes and deteriorated in fellow eyes. Conclusions Sleeping in dim light that can keep rods light adapted may reverse the changes of DMO. PMID:22020171
Toy, Brian C; Koo, Euna; Cukras, Catherine; Meyerle, Catherine B; Chew, Emily Y; Wong, Wai T
2012-05-01
To evaluate the safety and preliminary efficacy of intravitreal ranibizumab for nonneovascular idiopathic macular telangiectasia Type 2. Single-center, open-label Phase II clinical trial enrolling five participants with bilateral nonneovascular idiopathic macular telangiectasia Type 2. Intravitreal ranibizumab (0.5 mg) was administered every 4 weeks in the study eye for 12 months with the contralateral eye observed. Outcome measures included changes in best-corrected visual acuity, area of late-phase leakage on fluorescein angiography, and retinal thickness on optical coherence tomography. The study treatment was well tolerated and associated with few adverse events. Change in best-corrected visual acuity at 12 months was not significantly different between treated study eyes (0.0 ± 7.5 letters) and control fellow eyes (+2.2 ± 1.9 letters). However, decreases in the area of late-phase fluorescein angiography leakage (-33 ± 20% for study eyes, +1 ± 8% for fellow eyes) and in optical coherence tomography central subfield retinal thickness (-11.7 ± 7.0% for study eyes and -2.9 ± 3.5% for fellow eyes) were greater in study eyes compared with fellow eyes. Despite significant anatomical responses to treatment, functional improvement in visual acuity was not detected. Intravitreal ranibizumab administered monthly over a time course of 12 months is unlikely to provide a general and significant benefit to patients with nonneovascular idiopathic macular telangiectasia Type 2.
Postoperative Refraction in the Second Eye Having Cataract Surgery
Leffler, Christopher T.; Wilkes, Martin; Reeves, Juliana; Mahmood, Muneera A.
2011-01-01
Introduction. Previous cataract surgery studies assumed that first-eye predicted and observed postoperative refractions are equally important for predicting second-eye postoperative refraction. Methods. In a retrospective analysis of 173 patients having bilateral sequential phacoemulsification, multivariable linear regression was used to predict the second-eye postoperative refraction based on refractions predicted by the SRK-T formula for both eyes, the first-eye postoperative refraction, and the difference in IOL selected between eyes. Results. The first-eye observed postoperative refraction was an independent predictor of the second eye postoperative refraction (P < 0.001) and was weighted more heavily than the first-eye predicted refraction. Compared with the SRK-T formula, this model reduced the root-mean-squared (RMS) error of the predicted refraction by 11.3%. Conclusions. The first-eye postoperative refraction is an independent predictor of the second-eye postoperative refraction. The first-eye predicted refraction is less important. These findings may be due to interocular symmetry. PMID:24533181
The Sony PlayStation II EyeToy: low-cost virtual reality for use in rehabilitation.
Rand, Debbie; Kizony, Rachel; Weiss, Patrice Tamar L
2008-12-01
The objective of this study was to investigate the potential of using a low-cost video-capture virtual reality (VR) platform, the Sony PlayStation II EyeToy, for the rehabilitation of older adults with disabilities. This article presents three studies that were carried out to provide information about the EyeToy's potential for use in rehabilitation. The first study included the testing of healthy young adults (N = 34) and compared their experiences using the EyeToy with those using GestureTek's IREX VR system in terms of a sense of presence, level of enjoyment, control, success, and perceived exertion. The second study aimed to characterize the VR experience of healthy older adults (N = 10) and to determine the suitability and usability of the EyeToy for this population and the third study aimed to determine the feasibility of the EyeToy for use by individuals (N = 12) with stroke at different stages. The implications of these three studies for applying the system to rehabilitation are discussed.
New Eye Cleansing Product Improves Makeup-Related Ocular Problems.
Okura, Masako; Kawashima, Motoko; Katagiri, Mikiyuki; Shirasawa, Takuji; Tsubota, Kazuo
2015-01-01
Purpose. This study evaluated the effects of using a newly developed eye cleansing formulation (Eye Shampoo) to cleanse the eyelids for 4 weeks in a parallel-group comparative study in women with chronic eye discomfort caused by heavy use of eye makeup and poor eye hygiene habits. Methods. Twenty women participants who met the inclusion criteria were randomly allocated to 2 groups comprising 10 participants each. The participants were asked to use either artificial tears alone or artificial tears in conjunction with Eye Shampoo for 4 weeks. The participants answered the questionnaire again and were reexamined, and changes in symptoms within each group and variations of symptoms between the two groups were statistically analyzed. Results. In the group using only artificial tears, improvements in subjective symptoms but not in ophthalmologic examination results were found. In the group using Eye Shampoo together with artificial tears, significant improvements were observed in the subjective symptoms, meibomian orifice obstruction, meibum secretion, tear breakup time, and superficial punctate keratopathy. Conclusion. In patients with chronic eye discomfort thought to be caused by heavy eye makeup, maintaining eyelid hygiene using Eye Shampoo caused a marked improvement in meibomian gland blockage and dry eye symptoms.
New Eye Cleansing Product Improves Makeup-Related Ocular Problems
Okura, Masako; Kawashima, Motoko
2015-01-01
Purpose. This study evaluated the effects of using a newly developed eye cleansing formulation (Eye Shampoo) to cleanse the eyelids for 4 weeks in a parallel-group comparative study in women with chronic eye discomfort caused by heavy use of eye makeup and poor eye hygiene habits. Methods. Twenty women participants who met the inclusion criteria were randomly allocated to 2 groups comprising 10 participants each. The participants were asked to use either artificial tears alone or artificial tears in conjunction with Eye Shampoo for 4 weeks. The participants answered the questionnaire again and were reexamined, and changes in symptoms within each group and variations of symptoms between the two groups were statistically analyzed. Results. In the group using only artificial tears, improvements in subjective symptoms but not in ophthalmologic examination results were found. In the group using Eye Shampoo together with artificial tears, significant improvements were observed in the subjective symptoms, meibomian orifice obstruction, meibum secretion, tear breakup time, and superficial punctate keratopathy. Conclusion. In patients with chronic eye discomfort thought to be caused by heavy eye makeup, maintaining eyelid hygiene using Eye Shampoo caused a marked improvement in meibomian gland blockage and dry eye symptoms. PMID:26347812
Carracedo, Gonzalo; González-Méijome, José Manuel; Martín-Gil, Alba; Carballo, Jesús; Pintor, Jesús
2016-10-01
To evaluate the signs and symptoms of dry eye and dinucleotide secretion in tears of keratoconus patients (KC) and the potential effect of rigid gas permeable (RGP) contact lens wear. Twenty-three KC patients and forty control subjects were enrolled in this study. Signs of dry eye including tear volume, tear stability and corneal staining along with symptoms were assessed using the McMonnies questionnaire. Tears were collected using Schirmer strips, and dinucleotide concentrations in collected tears measured using high pressure liquid chromatography. Values obtained in KC and controls were compared. The effect of contact lens wear in KC was also assessed. KC eyes showed a significantly lower tear volume compared to controls, shorter tear break up time (TBUT), higher corneal staining and higher McMonnies dry eye questionnaire scores (p<0.05). When compared with non-wearers, KC contact lens wearers showed significantly higher symptoms, lower Schirmer and TBUT values (p<0.05). Concentration of Ap4A (0.695±0.304μM vs. 0.185±0.178μM) and Ap5A (0.132±0.128μM vs. 0.045±0.036μM) were higher in KC compared to controls (p<0.001) and only Ap4A was statistically higher in RGP wearers compared to non-wearers (0.794±0.478μM vs. 0.417±0.313μM) (p<0.05). Signs and symptoms of dry eye as well as concentrations of Ap4A and Ap5A were markedly increased in KC patients compared to controls. Moreover, Ap4A and symptoms of dry eye were statistically higher in RGP wearers compared to non-wearers. This seems to indicate that factors such as RGP contact lens wear might exacerbate the clinical condition of dry eye. Copyright © 2016 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Eye vs. Text Movement: Which Technique Leads to Faster Reading Comprehension?
ERIC Educational Resources Information Center
Abdellah, Antar Solhy
2009-01-01
Eye fixation is a frequent problem that faces foreign language learners and hinders the flow of their reading comprehension. Although students are usually advised to read fast/skim to overcome this problem, eye fixation persists. The present study investigates the effect of using a paper-based program as compared to a computer-based software in…
Quality of life of eye amputated patients.
Rasmussen, Marie L R; Ekholm, Ola; Prause, Jan U; Toft, Peter B
2012-08-01
To evaluate eye-amputated patients' health-related quality of life, perceived stress, self-rated health, job separation because of illness or disability and socioeconomic position. Patients were recruited from a tertiary referral centre situated in Copenhagen. Inclusion criteria were eye amputation, i.e. evisceration, enucleation, orbital exenteration or secondary implantation of an orbital implant during the period 1996-2003, and participation in a previous investigation (2005). In total, 159 eye-amputated patients were included, and completed a self-administered questionnaire containing health-related quality of life (SF-36), the perceived stress scale and answered questions about self-rated health, job changes because of illness or disability and socioeconomic status. These results were compared with findings from the Danish Health Interview Survey 2005. The eye-amputated patients had significantly (p < 0.05) lower scores (poorer health) on all SF-36 subscales and more perceived stress compared to the general population. In all, 43.3% of the patients rated their health as excellent or very good compared to 52.1% of the general population. In total, 25% of the study population has retired or changed to a part-time job because of eye disease. The percentage of eye amputated patients, who were divorced or separated, was twice as high as in the general population. The impact of an eye amputation is considerable. The quality of life, perceived stress and self-rated health of many eye-amputated patients are drastically changed. Eye amputation has a marked negative influence on job separation because of illness or disability and on socioeconomic position. © 2011 The Authors. Acta Ophthalmologica © 2011 Acta Ophthalmologica Scandinavica Foundation.
Cataract surgery in eyes with low corneal endothelial cell density.
Hayashi, Ken; Yoshida, Motoaki; Manabe, Shin-ichi; Hirata, Akira
2011-08-01
To compare corneal endothelial damage after cataract surgery in eyes with low endothelial cell density (ECD) and eyes with normal ECD. Hayashi Eye Hospital, Fukuoka, Japan. Case-control study. Cataract surgery was performed in eyes with a low ECD (500 to 1000 cells/mm(2)) (low-density group) and control eyes with a normal ECD. The ECD and central corneal thickness (CCT) were measured preoperatively and 1 and 3 months postoperatively, and the percentage cell loss and increase in CCT were compared. The low-density group and control group each comprised 50 eyes. In the low-density group, 39 eyes had nonprogressive endothelial pathology and 11 had Fuchs dystrophy. The mean ECD was significantly less and the CCT significantly greater in the low-density group than in the control group throughout the follow-up (P ≤.0066). However, no significant difference in the percentage of cell loss was found between groups at 1 or 3 months (5.1%, low-density group; 4.2%, control group) (P ≥.1477). The percentage increase in CCT was significantly greater in the low-density group than in the control group at 1 month (P<.0001), although there was no significant difference at 3 months (0.4% and -0.4%, respectively) (P=.2172). Corneal endothelial damage after cataract surgery in eyes with low ECD was slight and comparable to that in healthy eyes, which suggests that cataract surgery alone (without corneal transplantation) should be performed first. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Accuracy of noncycloplegic refraction performed at school screening camps.
Khurana, Rolli; Tibrewal, Shailja; Ganesh, Suma; Tarkar, Rajoo; Nguyen, Phuong Thi Thanh; Siddiqui, Zeeshan; Dasgupta, Shantanu
2018-06-01
The aim of this study was to compare noncycloplegic refraction performed in school camp with that performed in eye clinic in children aged 6-16 years. A prospective study of children with unaided vision <0.2 LogMAR who underwent noncycloplegic retinoscopy (NCR) and subjective refraction (SR) in camp and subsequently in eye clinic between February and March 2017 was performed. A masked optometrist performed refractions in both settings. The agreement between refraction values obtained at both settings was compared using the Bland-Altman analysis. A total of 217 eyes were included in this study. Between the school camp and eye clinic, the mean absolute error ± standard deviation in spherical equivalent (SE) of NCR was 0.33 ± 0.4D and that of SR was 0.26 ± 0.5D. The limits of agreement for NCR were +0.91D to - 1.09D and for SR was +1.15D to -1.06D. The mean absolute error in SE was ≤0.5D in 92.62% eyes (95% confidence interval 88%-95%). A certain degree of variability exists between noncycloplegic refraction done in school camps and eye clinic. It was found to be accurate within 0.5D of SE in 92.62% eyes for refractive errors up to 4.5D of myopia, 3D of cylinder, and 1.5D of hyperopia.
Clinical Outcome of Retinal Vasculitis and Predictors for Prognosis of Ischemic Retinal Vasculitis.
Sharief, Lazha; Lightman, Sue; Blum-Hareuveni, Tamar; Bar, Asaf; Tomkins-Netzer, Oren
2017-05-01
To determine factors affecting the visual outcome in eyes with retinal vasculitis and the rate of neovascularization relapse in ischemic vasculitis. Retrospective cohort study. We reviewed 1169 uveitis patients from Moorfields Eye Hospital, London, UK. Retinal vasculitis was observed in 236 eyes (121 ischemic, 115 nonischemic) that were compared with a control group (1022 eyes) with no retinal vasculitis. Ultra-widefield fluorescein angiography images were obtained in 63 eyes with ischemic vasculitis to quantify area of nonperfusion measured as ischemic index. The risk of vision loss was significantly more in the retinal vasculitis compared with the non-vasculitis group (hazard ratio [HR] 1.67, 95% confidence interval [CI] 1.24-2.25, P = .001). Retinal vasculitis had twice the risk of macular edema compared to the non-vasculitis group. Macular ischemia increased the risk of vision loss in vasculitis eyes by 4.4 times. The use of systemic prednisolone in eyes with vasculitis was associated with a reduced risk of vision loss (HR 0.36, 95% CI 0.15-0.82, P = .01). Laser photocoagulation was administered in 75 eyes (62.0%), out of which 29 (38.1%) had new vessel relapse and required additional laser treatment. The median ischemic index was 25.8% (interquartile range 10.2%-46%). Ischemia involving ≥2 quadrants was associated with increased risk of new vessel formation (HR 2.7, 95% CI 1.3-5.5, P = .003). Retinal vasculitis is associated with an increased risk of vision loss, mainly secondary to macular ischemia, and has a higher risk of macular edema compared to eyes with no vasculitis. Ischemia involving ≥2 quadrants is a risk factor for new vessel formation. Copyright © 2017 Elsevier Inc. All rights reserved.
Anitua, E; de la Fuente, M; Muruzabal, F; Riestra, A; Merayo-Lloves, J; Orive, G
2015-06-01
Autologous serum (AS) eye drops was the first blood-derived product used for the treatment of corneal pathologies but nowadays PRGF arises as a novel interesting alternative to this type of diseases. The purpose of this study was to evaluate and compare the biological outcomes of autologous serum eye drops or Plasma rich in growth factors (PRGF) eye drops on corneal stromal keratocytes (HK) and conjunctival fibroblasts (HConF). To address this, blood from healthy donors was collected and processed to obtain autologous serum (AS) eye drops and plasma rich in growth factors (PRGF) eye drops. Blood-derivates were aliquoted and stored at -80°C until use. PDGF-AB, VEGF, EGF, FGFb and TGF-β1 were quantified. The potential of PRGF and AS in promoting wound healing was evaluated by means of proliferation and migration assays in HK and HConF. Fibroblast cells were induced to myofibroblast differentiation after treatment with 2.5ng/mL of TGF-β1. The capability of PRGF and AS to prevent and inhibit TGF-β1-induced differentiation was evaluated. Results showed significant higher levels of all growth factors analyzed in PRGF eye drops compared to AS. Moreover, PRGF eye drops enhanced significantly the biological outcomes of both HK and HConF, and reduced TGF-β1-induced myofibroblast differentiation in contrast to autologous serum eye drops (AS). In summary, these results suggest that PRGF exerts enhanced biological outcomes than AS. PRGF may improve the treatment of ocular surface wound healing minimizing the scar formation compared to AS. Results obtained herein suggest that PRGF protects and reverses the myofibroblast phenotype while promotes cell proliferation and migration. Copyright © 2015 Elsevier Ltd. All rights reserved.
Kinoshita, Shigeru; Oshiden, Kazuhide; Awamura, Saki; Suzuki, Hiroyuki; Nakamichi, Norihiro; Yokoi, Norihiko
2013-06-01
To investigate the efficacy of 2% rebamipide ophthalmic suspension compared with 0.1% sodium hyaluronate ophthalmic solution for the treatment of patients with dry eye. Randomized, multicenter, active-controlled parallel-group study. One hundred eighty-eight patients with dry eye. Following a 2-week screening period, patients were allocated randomly to receive 2% rebamipide or 0.1% sodium hyaluronate, administered as 1 drop in each eye 4 or 6 times daily, respectively, for 4 weeks. There were 2 primary end points: changes in the fluorescein corneal staining (FCS) score to determine noninferiority of 2% rebamipide and changes in the lissamine green conjunctival staining (LGCS) score to determine superiority. Secondary objective end points were Schirmer's test results and tear film breakup time (TBUT). Secondary subjective end points were dry eye-related ocular symptoms (foreign body sensation, dryness, photophobia, eye pain, and blurred vision) score and the patients' overall treatment impression score. In the primary analysis, the mean change from baseline in FCS scores verified noninferiority, indicated significant improvement, and, in LGCS scores, verified the superiority of 2% rebamipide to 0.1% sodium hyaluronate. Values for the Schirmer's test and TBUT were comparable between the 2 groups. For 2 dry eye-related ocular symptoms--foreign body sensation and eye pain--2% rebamipide showed significant improvements over 0.1% sodium hyaluronate. Patients had a significantly more favorable impression of 2% rebamipide than of 0.1% sodium hyaluronate; 64.5% rated treatment as improved or markedly improved versus 34.7%, respectively. No serious adverse events were observed. Administration of 2% rebamipide was effective in improving both the objective signs and subjective symptoms of dry eye. Those findings, in addition to the well-tolerated profile of 2% rebamipide, clearly show that it is an effective therapeutic method for dry eye. Proprietary or commercial disclosure may be found after the references. Copyright © 2013 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Prevalence of dry eye syndrome and Sjogren's syndrome in patients with rheumatoid arthritis.
Kosrirukvongs, Panida; Ngowyutagon, Panotsom; Pusuwan, Pawana; Koolvisoot, Ajchara; Nilganuwong, Surasak
2012-04-01
Rheumatoid arthritis has manifestations in various organs including ophthalmic involvement. The present study evaluates prevalence of dry eye and secondary Sjogren's syndrome using salivary scintigraphy which has not been used in previous reports. To evaluate the prevalence of secondary Sjogren's syndrome in patients with rheumatoid arthritis, including clinical characteristics and dry eye, compared with non-Sjogren's syndrome. Descriptive cross sectional study Sixty-one patients with rheumatoid arthritis were recruited at Siriraj Hospital during March 2009-September 2010 and filled in the questionnaires about dry eye for Ocular Surface Disease Index (OSDI) with a history taking of associated diseases, medications, duration of symptoms of dry eyes and dry mouth. The Schirmer I test without anesthesia, tear break-up time, rose bengal staining score, severity of keratitis and salivary scintigraphy were measured and analyzed. Prevalence of secondary Sjogren's syndrome and dry eye were 22.2% (95% CI 15.4 to 30.9) and 46.7% (95% CI 38.0 to 55.6), respectively. Dry eye interpreted from OSDI, Schirmer 1 test, tear break-up time and rose bengal staining was 16.4%, 46.7%, 82% and 3.3% respectively. Fifty-two percent of patients had a history of dry eye and dry mouth with mean duration 27.4 and 29.8 months, respectively. Superficial punctate keratitis and abnormal salivary scintigraphy were found in 58.2% and 77.8%. Duration of rheumatoid arthritis, erythrocyte sedimentation rate were not correlated with secondary Sjogren's syndrome. Dry eye from OSDI with secondary Sjogren's syndrome (33.3%) compared with non-Sjogren's syndrome (9.5%) was significant difference (p = 0.008). Adjusted odds ratio for secondary Sjogren's syndrome in OSDIL score > 25 was 13.8 (95% CI 2.6 to 73.8, p = 0.002) compared to OSDI score < 25. Awareness and detection of dry eye syndrome and secondary Sjogren's syndrome in rheumatoid arthritis was crucial for evaluation of their severity and proper management.
A panoramic imaging system based on fish-eye lens
NASA Astrophysics Data System (ADS)
Wang, Ye; Hao, Chenyang
2017-10-01
Panoramic imaging has been closely watched as one of the major technologies of AR and VR. Mainstream panoramic imaging techniques lenses include fish-eye lenses, image splicing, and catadioptric imaging system. Meanwhile, fish-eyes are widely used in the big picture video surveillance. The advantage of fish-eye lenses is that they are easy to operate and cost less, but how to solve the image distortion of fish-eye lenses has always been a very important topic. In this paper, the image calibration algorithm of fish-eye lens is studied by comparing the method of interpolation, bilinear interpolation and double three interpolation, which are used to optimize the images.
Becker, Silke; Wang, Haibo; Stoddard, Gregory J; Hartnett, M Elizabeth
2017-01-01
Subretinal injections are used to deliver agents in experimental studies of retinal diseases, often through viral vectors. However, few studies have investigated the effects of subretinal injections alone on the structure and function of the healthy or diseased retina, particularly in models of oxygen-induced retinopathy (OIR). We report on the effects of subretinal injections in a rat OIR model, which is used to study mechanisms of retinopathy of prematurity. Within 6 h of birth, neonatal rat pups were exposed to repeated cycles of oxygen between 50% and 10% O 2 every 24 h for 14 days and subsequently moved to room air. On postnatal day 8 (P8), animals were treated in both eyes with advancement of the injection needle into the vitreous (pilot-treated) or with a subretinal PBS injection (sPBS-treated) or were left untreated (untreated). Additional control animals were exposed to microscope light after eyelid opening only (light-treated). Retinal fundus images were recorded on P26. Areas of the avascular retina and intravitreal neovascularization were determined in flat mounted retinas stained with isolectin B4 on P32. Retinal function of the respective eyes was assessed with the Ganzfeld electroretinogram (ERG) on P31 or P32 and with focal ERG in the central retina on P28 or P29. The thickness of the retinal layers was measured with spectral domain optical coherence tomography (OCT) on P30 and in opsin- and TO-PRO 3-stained retinal cryosections from pups euthanized on P32. Two sections were analyzed in each pup. For each section, three images of three different locations were analyzed accounting for 18 thickness measurements per pup. Compared to untreated animals, the avascular area of the retina was greater in the pilot-treated (p<0.05) and sPBS-treated eyes (p<0.01), and the sPBS-treated eyes had a greater avascular retinal area compared to the pilot-treated eyes (p<0.01). The intravitreal neovascular area was larger in the sPBS-treated eyes compared to the untreated eyes (p<0.01). The outer nuclear and outer segment layers were thinner in the pilot- (p<0.01) and sPBS-treated eyes (p<0.05) compared to the untreated eyes as measured with OCT and immunohistochemical staining of the retinal cryosections. Compared to the untreated eyes, the amplitudes of the scotopic a- and b-waves in the Ganzfeld ERG were reduced in the pilot-treated eyes (p<0.001 and p<0.01, respectively), but only the a-wave was reduced in the sPBS-treated eyes (p<0.001). The a-wave amplitude in the focal ERG was reduced in the pilot- and sPBS-treated eyes, and no difference was seen in the b-wave amplitude between any of the groups. There was no difference between the light-treated and untreated eyes in the areas of the avascular retina or intravitreal neovascularization or Ganzfeld or focal ERG. Pilot injections alone without injection into the subretinal space resulted in an increased avascular retinal area, reduced thickness of the photoreceptors, and reduced ERG function compared to the untreated animals. Although subretinal PBS injections further increased the areas of avascular retina and intravitreal neovascularization and resulted in similar retinal thinning compared to the pilot treatment, inner retinal function was improved, as evidenced by higher Ganzfeld b-wave amplitudes. Differences in the Ganzfeld and focal ERGs may indicate that the peripheral retina is more susceptible to remote beneficial effects from potential protective mechanisms induced by subretinal injection. This study stresses the importance of appropriate controls in experiments with subretinal delivery of agents.
Burkholder, Bryn M; Wang, Jiangxia; Dunn, James P; Nguyen, Quan D; Thorne, Jennifer E
2013-09-01
To evaluate outcomes after placement of fluocinolone acetonide (FA) implants in eyes with birdshot chorioretinitis and to compare these outcomes with eyes with posterior and panuveitis. This is a retrospective cohort study of 48 eyes from patients with posterior and panuveitis treated with FA implants from 2006 to 2010. Outcome measures include visual acuity, intraocular pressure, need for glaucoma surgery, postoperative complications, and control of inflammation. All eyes treated with FA implants achieved improved control of inflammation and decreased reliance on adjunctive therapy. Birdshot chorioretinitis eyes had a statistically significant increase in intraocular pressure in the first 4 months after FA implantation (P = 0.04) compared with baseline intraocular pressure. A higher percentage of eyes with birdshot chorioretinitis required glaucoma surgery and after a shorter time period after FA implantation than did eyes with other forms of posterior and panuveitis (0.42/eye-year vs. 0.11/eye-year; median time to glaucoma surgery: 15.5 months vs. 31.5 months respectively, hazard ratio, 3.4; 95% confidence interval, 1.0-10.8, P = 0.04). Although the FA implant is effective in controlling inflammation and reducing the need for systemic immunosuppressive therapy, eyes of patients with birdshot chorioretinitis tend to have a more robust intraocular pressure response to the FA implant than eyes with other types of posterior and panuveitis.
Exploring the Predisposition of the Asian Eye to Development of Dry Eye.
Craig, Jennifer P; Wang, Michael T M; Kim, Dabin; Lee, Jung Min
2016-07-01
To investigate the influence of eyelid shape on tear film quality, ocular surface characteristics and dry eye symptomatology by comparing Asian and Caucasian populations. Seventy-four age-matched participants were recruited in a cross-sectional study. Participants were classified into Asian single lid (ASL), Asian double lid (ADL), and Caucasian double lid (CDL) groups. Dry eye symptomatology, ocular surface characteristics, and tear film quality were evaluated in a single clinical session. Meibomian gland dropout was significantly greater in both the ASL and ADL groups than in the CDL group (all P<.05). A greater proportion of ASL and ADL participants exhibited incomplete blinking than CDL patients (all P<.05). There were no significant differences in tear film quality and dry eye symptomatology between the three groups (all P>.05). Exposed ocular surface area, lissamine green staining, and lid wiper epitheliopathy were significantly greater in the ADL group compared to the CDL group (all P<.05). The CDL group displayed significantly greater anterior blepharitis and lid telangiectasia grades compared to both ASL and ADL groups (all P<.05). A higher degree of meibomian gland dropout and incomplete blinking was observed in both Asian groups compared to the Caucasian group, potentially predisposing these groups to dry eye. Copyright © 2016 Elsevier Inc. All rights reserved.
Visual acuity deficits in the fellow eyes of children with unilateral amblyopia.
Varadharajan, Srinivasa; Hussaindeen, Jameel Rizwana
2012-02-01
To study the visual acuity deficits and maturation in the fellow eyes of children with unilateral amblyopia who were treated with patching. Medical records of patients aged 4-13 years visiting a tertiary eye care center between January 2003 and December 2007 who were diagnosed for the first time with unilateral amblyopia were reviewed. Subjects included in the study were followed through April 2009. The baseline visual acuity in the fellow eye of amblyopic subjects was compared with that of age-matched healthy subjects. Changes in visual acuity in the amblyopic and fellow eyes during subsequent visits were analyzed. A total of 112 children with amblyopia were included (strabismic, 14; anisometropic, 51; combined mechanism, 47). Baseline visual acuity in the fellow eye of these children differed significantly from that of age-matched controls up to 8 years of age. Average logMAR acuity reached 0.0 at age 5 years in controls versus age 9 years in patients. Although the mean visual acuity of the fellow eyes improved during treatment, 21% developed temporary occlusion amblyopia. Full-time patching had no additional benefit when compared with part-time patching. Visual acuity in the fellow eye of children with unilateral amblyopia is reduced at baseline and matures more slowly than in healthy control patients. The risk for temporary occlusion amblyopia in the fellow eye is similar what has been previously reported. Copyright © 2012 American Association for Pediatric Ophthalmology and Strabismus. Published by Mosby, Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
McIntire, Lindsey K.; McKinley, R. Andy; Goodyear, Chuck; McIntire, John P.
2017-05-01
The purpose of this study is to determine the ability of an eye-tracker to detect changes in vigilance performance compared to the common method of using cerebral blood flow velocities (CBFV). Sixteen subjects completed this study. Each participant performed a 40-minute vigilance task while wearing an eye-tracker and a transcranial doppler (TCD) on each of four separate days. The results indicate that percentage of eye closure (PERCLOS) measured by the eye-tracker increased as vigilance performance declined and right CBFV as measured by the TCD decreased as performance declined. The results indicate that PERCLOS (left eye r=-.72 right eye r=-.67) more strongly correlated with changes in performance when compared to CBFV (r=.54). We conclude that PERCLOS, as measured by a head-worn eye tracking system, may serve as a compelling alternative (or supplemental) indicator of impending or concurrent performance declines in operational settings where sustained attention or vigilance is required. Such head-worn or perhaps even offbody oculometric sensor systems could potentially overcome some of the practical disadvantages inherent with TCD data collection for operational purposes. If portability and discomfort challenges with TCD can be overcome, both TCD and eye tracking might be advantageously combined for even greater performance monitoring than can be offered by any single device.
Said, Azza Mohamed Ahmed; Farag, Mona Elsayed; Abdulla, Tarek Mohamed; Ziko, Othman Ali Othman; Osman, Wesam Mohamed
2016-01-01
AIM To evaluate the effect of punctal occlusion using thermosensitive (smart plug) versus silicone plug for management of aqueous deficient dry eye on corneal sensitivity, ocular surface health and tear film stability. METHODS A comparative prospective interventional case study included 45 patients with bilateral severe form of aqueous deficient dry eye. In each patient, the smart plug was inserted in the lower punctum of the right eye which was considered as study group 1 and silicone plug was inserted in the lower punctum of the left eye of the same patient which was considered as study group 2. All patients were subjected to careful history taking and questionnaire for subjective assessment of severity of symptoms. Corneal sensitivity, corneal fluorescein, rose bengal staining, Schirmer's I test, tear film break up time and conjunctival impression cytology were performed pre and 1, 3 and 6mo post plug insertion. RESULTS A statistically significant improvement in subjective and objective manifestations occurred following treatment with both types of plugs (P<0.01). The thermosensitive plug caused significant overall improvement, decrease in frequency of application of tear substitutes and improvement of conjunctival impression cytology parameters in the inserted side (P<0.01). Canaliculitis was reported in two eyes (4.4%) following punctal occlusion using thermosensitive plug (study group 1). Spontaneous plug loss occurred in 21 eyes (46.6%) in the silicone plug group (study group 2). CONCLUSION Improvement of subjective and objective manifestations of aqueous deficient dry eye occurs following punctal plug occlusion. Thermosensitive plug has good patient's compliance with fewer complications and lower rates of loss compared to the silicone plug. PMID:27990362
Göbbels, M; Gross, D
1996-01-01
In this controlled, randomized, double-masked study the effect of dexpanthenol-containing artificial tears (Siccaprotect) on patients with dry eyes was examined. 50 patients applied either dexpanthenol-containing artificial tears (Siccaprotect) or the identical, but free of dexpanthenol, eye drops five times daily into the conjunctival sac. No other ophthalmics were administered. The corneal epithelial permeability was measured by fluorophotometry and Schirmer-Test, Rose Bengal staining, tear film break-up time and the patients' subjective complaints were determined before and after 6 weeks of treatment. The dexpanthenol-containing artificial tears (Siccaprotect) improved disturbances of the corneal epithelial permeability significantly in comparison to the dexpanthenol-free eyes drops. The other parameters didn't show relevant differences. These data suggest that, in dry eyes, treatment with dexpanthenol-containing eye drops leads to a favorable and comparing with dexpanthenol-free eye drops superior improvement in disturbances of corneal epithelium permeability.
Werner, Liliana; Pandey, Suresh K; Izak, Andrea M; Vargas, Luis G; Trivedi, Rupal H; Apple, David J; Mamalis, Nick
2004-05-01
To evaluate the development of capsular bag opacification in rabbit eyes after implantation of an intraocular lens (IOL) designed to minimize contact between the anterior capsule and the IOL and ensure expansion of the capsular bag. David J. Apple, MD Laboratories for Ophthalmic Devices Research, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. Ten New Zealand white rabbits had a study IOL (new accommodating silicone IOL [Synchrony, Visiogen, Inc.]) implanted in 1 eye and a control IOL (1-piece plate silicone IOL with large fixation holes) implanted in the other eye. Intraocular lens position, anterior capsule opacification (ACO), and posterior capsule opacification (PCO) were qualitatively assessed using slitlamp retroillumination photographs of the dilated eyes. Anterior capsule opacification and PCO were graded on a 0 to 4 scale after the eyes were enucleated (Miyake-Apple posterior and anterior views after excision of the cornea and iris). The eyes were also evaluated histopathologically. The rate of ACO and PCO was significantly higher in the control group. Fibrosis and ACO were almost absent in the study group; the control group exhibited extensive capsulorhexis contraction, including capsulorhexis occlusion. Postoperative IOL dislocation into the anterior chamber and pupillary block syndrome were observed in some eyes in the study group. The special design features associated with the study IOL appeared to help prevent PCO. Complications in the study group were probably caused by the increased posterior vitreous pressure in rabbit eyes compared to human eyes and the relatively large size of the study IOL relative to the anterior segment of rabbit eyes.
Multifocal versus monofocal intraocular lenses after cataract extraction.
de Silva, Samantha R; Evans, Jennifer R; Kirthi, Varo; Ziaei, Mohammed; Leyland, Martin
2016-12-12
Good unaided distance visual acuity (VA) is now a realistic expectation following cataract surgery and intraocular lens (IOL) implantation. Near vision, however, still requires additional refractive power, usually in the form of reading glasses. Multiple optic (multifocal) IOLs are available which claim to allow good vision at a range of distances. It is unclear whether this benefit outweighs the optical compromises inherent in multifocal IOLs. To assess the visual effects of multifocal IOLs in comparison with the current standard treatment of monofocal lens implantation. We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register) (2016, Issue 5), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to June 2016), Embase (January 1980 to June 2016), the ISRCTN registry (www.isrctn.com/editAdvancedSearch), ClinicalTrials.gov (www.clinicaltrials.gov), and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 13 June 2016. All randomised controlled trials comparing a multifocal IOL of any type with a monofocal IOL as control were included. Both unilateral and bilateral implantation trials were included. We also considered trials comparing multifocal IOLs with "monovision" whereby one eye is corrected for distance vision and one eye corrected for near vision. We used standard methodological procedures expected by Cochrane. We assessed the 'certainty' of the evidence using GRADE. We found 20 eligible trials that enrolled 2230 people with data available on 2061 people (3194 eyes). These trials were conducted in Europe (13), China (three), USA (one), Middle East (one), India (one) and one multicentre study in Europe and the USA. Most of these trials compared multifocal with monofocal lenses; two trials compared multifocal lenses with monovision. There was considerable variety in the make and model of lenses implanted. Overall we considered the trials at risk of performance and detection bias because it was difficult to mask participants and outcome assessors. It was also difficult to assess the role of reporting bias.There was moderate-certainty evidence that the distance acuity achieved with multifocal lenses was not different to that achieved with monofocal lenses (unaided VA worse than 6/6: pooled RR 0.96, 95% confidence interval (CI) 0.89 to 1.03; eyes = 682; studies = 8). People receiving multifocal lenses may achieve better near vision (RR for unaided near VA worse than J3/J4 was 0.20, 95% CI 0.07 to 0.58; eyes = 782; studies = 8). We judged this to be low-certainty evidence because of risk of bias in the included studies and high heterogeneity (I 2 = 93%) although all included studies favoured multifocal lenses with respect to this outcome.People receiving multifocal lenses may be less spectacle dependent (RR 0.63, 95% CI 0.55 to 0.73; eyes = 1000; studies = 10). We judged this to be low-certainty evidence because of risk of bias and evidence of publication bias (skewed funnel plot). There was also high heterogeneity (I 2 = 67%) but all studies favoured multifocal lenses. We did not additionally downgrade for this.Adverse subjective visual phenomena were more prevalent and more troublesome in participants with a multifocal IOL compared with monofocals (RR for glare 1.41, 95% CI 1.03 to 1.93; eyes = 544; studies = 7, low-certainty evidence and RR for haloes 3.58, 95% CI 1.99 to 6.46; eyes = 662; studies = 7; moderate-certainty evidence).Two studies compared multifocal lenses with monovision. There was no evidence for any important differences in distance VA between the groups (mean difference (MD) 0.02 logMAR, 95% CI -0.02 to 0.06; eyes = 186; studies = 1), unaided intermediate VA (MD 0.07 logMAR, 95% CI 0.04 to 0.10; eyes = 181; studies = 1) and unaided near VA (MD -0.04, 95% CI -0.08 to 0.00; eyes = 186; studies = 1) compared with people receiving monovision. People receiving multifocal lenses were less likely to be spectacle dependent (RR 0.40, 95% CI 0.30 to 0.53; eyes = 262; studies = 2) but more likely to report problems with glare (RR 1.41, 95% CI 1.14 to 1.73; eyes = 187; studies = 1) compared with people receiving monovision. In one study, the investigators noted that more people in the multifocal group underwent IOL exchange in the first year after surgery (6 participants with multifocal vs 0 participants with monovision). Multifocal IOLs are effective at improving near vision relative to monofocal IOLs although there is uncertainty as to the size of the effect. Whether that improvement outweighs the adverse effects of multifocal IOLs, such as glare and haloes, will vary between people. Motivation to achieve spectacle independence is likely to be the deciding factor.
Kaido, Minako; Kawashima, Motoko; Ishida, Reiko; Tsubota, Kazuo
2016-03-01
The purpose of this prospective comparative study was to investigate corneal sensitivity in subjects with unstable tear film, with and without dry eye (DE) symptoms. Forty-one eyes of 41 volunteers (mean age: 45.1 ± 9.4 years; age range, 23-57 years), with normal tear function and ocular surface except for tear stability, were studied. The eyes were divided into two groups depending on the presence or absence of DE symptoms: 21 eyes with DE symptoms (symptomatic group); and 20 eyes without DE symptoms (asymptomatic group). Three types of corneal sensitivity values were measured using a Cochet-Bonnet esthesiometer: the sensitivity for perception of touch (S-touch), the sensitivity for blinking (S-blink), and the sensitivity for pain (S-pain). Mean S-blink and S-pain were significantly higher in the symptomatic group than in the asymptomatic group (P < 0.05), whereas there was no significant difference in mean S-touch between these groups (P > 0.05). Corneal sensitivity for blinking and pain evoked by increased stimuli was higher in the symptomatic group (subjects with short break-up time DE) compared with subjects who have no DE symptoms despite decreased tear stability. The presence of both tear instability and hyperesthesia, rather than tear instability alone, may contribute to DE pathogenesis.
2014-01-01
Background Achieving independent upright posture has known to be one of the main goals in rehabilitation following lower limb amputation. The purpose of this study was to compare postural steadiness of below knee amputees with visual alterations while wearing three different prosthetic feet. Methods Ten male below-knee amputees were instructed to stand quietly on the Biodex® balance platform while wearing solid ankle cushion heel (SACH), single axis (SA) and energy storage and release (ESAR) prosthetic foot under different visual input conditions (eyes-opened and eyes-closed). The overall stability index (OSI), anterior- posterior stability index (APSI), and medial-lateral stability index (MLSI) were computed. Perceived balance assessment of each foot was evaluated using Activities-specific Balance Confidence (ABC) score. Results The findings highlights that SACH showed lowest overall stability index (indicating less body sway) during eyes-opened (OSI: SACH = 1.09, SA = 1.58, ESAR = 1.59) and SA showed lowest overall stability index during eyes-closed (OSI: SACH = 2.52, SA = 2.30, ESAR = 2.76) condition. However, overall stability indexes between foot types did not differ significantly during eyes-opened or eyes-closed (p = 0.651). There was a trend of instability which occurred more in medial-lateral compared to anterior-posterior direction for all foot types, with significant result in ESAR foot(eyes-opened: MLSI = 1.59, APSI = 0.65, p = 0.034; eyes-closed: MLSI = 2.76, APSI = 1.80, p = 0.017, respectively). When comparing between visual conditions, stability score was significantly higher during eyes-closed compared to eyes-opened situations for SACH and ESAR foot (eyes-closed vs opened; SACH OSI: 3.43 vs 1.71, p = 0.018 and MLSI: 3.43 vs 1.71, p = 0.018; ESAR OSI: 3.58 vs 1.86, p = 0.043 and APSI: 1.80 vs 0.65, p = 0.027). Conclusions The results of this study suggested postural steadiness in below-knee amputees was not affected by the types of prosthetic foot during quiet upright standing, but was significantly affected when visual cues was absent. PMID:24597518
Effect of four different intraocular lenses on posterior capsule opacification
Duman, Rahmi; Karel, Fatih; Özyol, Pelin; Ateş, Can
2015-01-01
AIM To evaluate the impact of 4 different intraocular lenses (IOLs) on posterior capsule opacification (PCO) by comparing the neodymium: yttrium-aluminum-garnet (Nd:YAG) laser capsulotomy rates. METHODS This retrospective study included 4970 eyes of 4013 cataract patients who underwent phacoemulsification and IOL implantation between January 2000 and January 2008 by the same surgeon at one clinic. Four different IOLs were assessed. The outcome parameter was the incidence of Nd:YAG laser posterior capsulotomies. RESULTS An Nd:YAG laser posterior capsulotomy was performed in 153 (3.07%) of the 4970 eyes. The mean follow-up time was 84mo for all of the IOL groups. The percentage of eyes developing PCO was significantly greater for the acrylic hydrophilic IOLs than for the hydrophobic IOLs, although eyes with acrylic hydrophilic IOLs did not require Nd:YAG laser capsulotomy as soon as eyes with acrylic hydrophobic IOLs. There was no difference between the long-term PCO rates when 1- and 3-piece acrylic hydrophobic IOLs were compared or when IOLs made of the same material but with different haptic angles were compared. CONCLUSION In this study, eyes with acrylic hydrophilic IOLs were more likely to develop PCO than those with acrylic hydrophobic IOLs. The lens design (1-piece versus 3-piece and varying haptic angles) did not affect the PCO rate. PMID:25709920
Lin, Jane-Ming; Chen, Wen-Lu; Chiang, Chun-Chi; Tsai, Yi-Yu
2008-04-01
To evaluate ablation centration of flying-spot LASIK, investigate the effect of patient- and surgeon-related factors on centration, and compare flying-spot and broad-beam laser results. This retrospective study comprised 173 eyes of 94 patients who underwent LASIK with the Alcon LADARVision4000 with an active eye-tracking system. The effective tracking rate of the system is 100 Hz. The amount of decentration was analyzed by corneal topography. Patient- (low, high, and extreme myopia; effect of learning) and surgeon-related (learning curve) factors influencing centration were identified. Centration was compared to the SCHWIND Multiscan broad-beam laser with a 50-Hz tracker from a previous study. Mean decentration was 0.36+/-0.18 mm (range: 0 to 0.9 mm). Centration did not differ in low, high, and extreme myopia or in patients' first and second eyes. There were no significant differences in centration between the first 50 LASIK procedures and the last 50 procedures. Comparing flying-spot and broad-beam laser results, there were no differences in centration in low myopia. However, the LADARVision4000 yielded better centration results in high and extreme myopia. The Alcon LADARVision4000 active eye tracking system provides good centration for all levels of myopic correction and better centration than the Schwind broad-beam Multiscan in eyes with high and extreme myopia.
Morphological Features and Important Parameters of Large Optic Discs for Diagnosing Glaucoma
Okimoto, Satoshi; Yamashita, Keiko; Shibata, Tetsuo; Kiuchi, Yoshiaki
2015-01-01
Purpose To compare the optic disc parameters of glaucomatous eyes to those of non-glaucomatous eyes with large discs. Methods We studied 225 consecutive eyes with large optic discs (>2.82 mm2): 91 eyes with glaucoma and 134 eyes without glaucoma. An eye was diagnosed with glaucoma when visual field defects were detected by the Humphrey Field Analyzer. All of the Heidelberg Retina Tomograph II (HRT II) parameters were compared between the non-glaucomatous and glaucomatous eyes. A logistic regression analysis of the HRT II parameters was used to establish a new formula for diagnosing glaucoma, and the sensitivity and specificity of the Moorfields Regression Analysis (MRA) was compared to the findings made by our analyses. Results The mean disc area was 3.44±0.50 mm2 in the non-glaucomatous group and 3.40±0.52 mm2 in the glaucoma group. The cup area, cup volume, cup-to-disc area ratio, linear cup/disc ratio, mean cup depth, and the maximum cup depth were significantly larger in glaucomatous eyes than in the non-glaucomatous eyes. The rim area, rim volume, cup shape measurement, mean retinal nerve fiber layer (RNFL) thickness, and RFNL cross-sectional area were significantly smaller in glaucomatous eyes than in non-glaucomatous eyes. The cup-to-disc area ratio, the height variation contour (HVC), and the RNFL cross-sectional area were important parameters for diagnosing the early stage glaucoma, and the cup-to-disc area ratio and cup volume were useful for diagnosing advanced stage glaucoma in eyes with a large optic disc. The new formula had higher sensitivity and specificity for diagnosing glaucoma than MRA. Conclusions The cup-to-disc area ratio, HVC, RNFL cross-sectional area, and cup volume were important parameters for diagnosing glaucoma in eyes with a large optic disc. The important disc parameters to diagnose glaucoma depend on the stage of glaucoma in patients with large discs. PMID:25798580
Effects of monocular viewing and eye dominance on spatial attention.
Roth, Heidi L; Lora, Andrea N; Heilman, Kenneth M
2002-09-01
Observations in primates and patients with unilateral spatial neglect have suggested that patching of the eye ipsilateral to the injury and contralateral to the neglected space can sometimes improve attention to the neglected space. Investigators have generally attributed the effects of monocular eye patching to activation of subcortical centers that interact with cortical attentional systems. Eye patching is thought to produce preferential activation of attentional systems contralateral to the viewing eye. In this study we examined the effect of monocular eye patching on attentional biases in normal subjects. When normal subjects bisect vertical (radial) lines using both eyes, they demonstrate a far attentional bias, misbisecting lines away from their body. In a monocular viewing experiment, we found that the majority of subjects, who were right eye dominant, had relatively nearer bisections and a diminished far bias when they used their right eye (left eye covered) compared with when they used their left eye (right eye covered). The smaller group of subjects who were left eye dominant had relatively nearer bisections and a diminished far bias when they used their left eye compared with when they used their right eye. In the hemispatial placement experiment, we directly manipulated hemispheric engagement by having subjects perform the same task in right and left hemispace. We found that right eye dominant subjects had a diminished far bias in right hemispace relative to left hemispace. Left eye dominant subjects showed the opposite pattern and had a diminished far bias in left hemispace. For both groups, spatial presentation affected performance more for the non-dominant eye. The results suggest that monocular viewing is associated with preferential activation of attentional systems in the contralateral hemisphere, and that the right hemisphere (at least in right eye dominant subjects) is biased towards far space. Finally, the results suggest that the poorly understood phenomenon of eye dominance may be related to hemispheric specialization for visual attention.
Bhandary, Sulatha; Khanna, Rajesh; Rao, Krishna A; Rao, Lavanya G; Lingam, Kamala D; Binu, V
2011-01-01
Aim: Corneal blindness accounts for 3.42% of blindness in Malaysia; the rate of eye donation is low. The aim of the study was to assess the awareness about eye donation and willingness to donate eyes among attendants of patients at various clinics in Melaka, Malaysia. Materials and Methods: This observational study was conducted on attendants who accompanied patients (n = 400) visiting various outpatient departments of the General Hospital and two peripheral clinics in Melaka between August and October 2007. The participants answered a questionnaire (Malay and English versions) which included demographic profile, awareness of eye donation, knowledge regarding facts of eye donation, and willingness to donate eyes. Univariate and multivariate logistic regression was performed at 5% level of significance. Results: Awareness of eye donation was observed in 276 (69%) participants. Multivariate analysis showed that awareness was more among females when compared to males (P = 0.009). Of the 276 participants who were aware of eye donation, only 34.42% were willing to donate eyes. Willingness was more among the Indian race (P = 0.02) and males (P = 0.02). Educational status did not influence the willingness to donate eyes. Conclusions: Although majority of participants were aware of eye donation, willingness to donate eyes was poor. PMID:21157071
Pośpiech, Ewelina; Karłowska-Pik, Joanna; Ziemkiewicz, Bartosz; Kukla, Magdalena; Skowron, Małgorzata; Wojas-Pelc, Anna; Branicki, Wojciech
2016-07-01
The genetics of eye colour has been extensively studied over the past few years, and the identified polymorphisms have been applied with marked success in the field of Forensic DNA Phenotyping. A picture that arises from evaluation of the currently available eye colour prediction markers shows that only the analysis of HERC2-OCA2 complex has similar effectiveness in different populations, while the predictive potential of other loci may vary significantly. Moreover, the role of gender in the explanation of human eye colour variation should not be neglected in some populations. In the present study, we re-investigated the data for 1020 Polish individuals and using neural networks and logistic regression methods explored predictive capacity of IrisPlex SNPs and gender in this population sample. In general, neural networks provided higher prediction accuracy comparing to logistic regression (AUC increase by 0.02-0.06). Four out of six IrisPlex SNPs were associated with eye colour in the studied population. HERC2 rs12913832, OCA2 rs1800407 and SLC24A4 rs12896399 were found to be the most important eye colour predictors (p < 0.007) while the effect of rs16891982 in SLC45A2 was less significant. Gender was found to be significantly associated with eye colour with males having ~1.5 higher odds for blue eye colour comparing to females (p = 0.002) and was ranked as the third most important factor in blue/non-blue eye colour determination. However, the implementation of gender into the developed prediction models had marginal and ambiguous impact on the overall accuracy of prediction confirming that the effect of gender on eye colour in this population is small. Our study indicated the advantage of neural networks in prediction modeling in forensics and provided additional evidence for population specific differences in the predictive importance of the IrisPlex SNPs and gender.
Evolution of eye size and shape in primates.
Ross, Callum F; Kirk, E Christopher
2007-03-01
Strepsirrhine and haplorhine primates exhibit highly derived features of the visual system that distinguish them from most other mammals. Comparative data link the evolution of these visual specializations to the sequential acquisition of nocturnal visual predation in the primate stem lineage and diurnal visual predation in the anthropoid stem lineage. However, it is unclear to what extent these shifts in primate visual ecology were accompanied by changes in eye size and shape. Here we investigate the evolution of primate eye morphology using a comparative study of a large sample of mammalian eyes. Our analysis shows that primates differ from other mammals in having large eyes relative to body size and that anthropoids exhibit unusually small corneas relative to eye size and body size. The large eyes of basal primates probably evolved to improve visual acuity while maintaining high sensitivity in a nocturnal context. The reduced corneal sizes of anthropoids reflect reductions in the size of the dioptric apparatus as a means of increasing posterior nodal distance to improve visual acuity. These data support the conclusion that the origin of anthropoids was associated with a change in eye shape to improve visual acuity in the context of a diurnal predatory habitus.
Rokohl, Alexander C; Koch, Konrad R; Adler, Werner; Trester, Marc; Trester, Wolfgang; Pine, Nicola S; Pine, Keith R; Heindl, Ludwig M
2018-06-01
To compare the concerns of experienced cryolite glass and (poly)methyl methacrylate (PMMA) prosthetic eye wearers. One hundred six experienced cryolite glass and 63 experienced PMMA prosthetic eye wearers completed an anonymous questionnaire regarding general and specific prosthetic eye concerns at least 2 years after natural eye loss. From these independent anophthalmic populations, we identified 34 case-control pairs matched for the known influencing demographic variables of gender, occupation, age, and time since natural eye loss. The levels of concern were significantly lower in the cryolite glass group than those in the PMMA group for the following: loss of balance (p < 0.001), phantom sight vision (p < 0.001), pain (p < 0.001), receiving good advice (p = 0.001), fullness of orbit (p = 0.001), size (p = 0.007), direction of gaze relative to the healthy fellow eye (p = 0.005), eye lid contour (p = 0.037), comfort of the prosthetic eye (p < 0.001), colour relative to the healthy fellow eye (p < 0.001), and retention of the prosthetic eye (p < 0.001). Concerns about watering, crusting, discharge, visual perception, appearance, movement of the prosthetic eye, and health of the remaining eye were not significantly different between both groups. The results of this study showed that many general and specific levels of concern were significantly lower for cryolite glass prosthetic eye wearers than for PMMA prosthetic eye wearers. The question of why there are significant differences and to what extent the material of the prosthesis (cryolite glass or PMMA) has an impact on various concerns remains unanswered and should be addressed in a prospective comparative multicentre trial.
Vestergaard, Anders; Ivarsen, Anders; Asp, Sven; Hjortdal, Jesper Ø
2013-06-01
To present our initial clinical experience with ReLEx(®) flex (ReLEx) for moderate to high myopia. We compare efficacy, safety and corneal higher-order aberrations after ReLEx with femtosecond laser in situ keratomileusis (FS-LASIK). Prospective study of ReLEx compared with a retrospective study of FS-LASIK. ReLEx is a new keratorefractive procedure, where a stromal lenticule is cut by a femtosecond laser and manually extracted. Forty patients were treated with ReLEx on both eyes. A comparable group of 41 FS-LASIK patients were retrospectively identified. Visual acuity, spherical equivalent (SE) and corneal tomography were measured before and 3 months after surgery. Preoperative SE averaged -7.50 ± 1.16 D (ReLEx) and -7.32 ± 1.09 D (FS-LASIK). For all eyes, mean corrected distance visual acuity remained unchanged in both groups. For eyes with emmetropia as target refraction, 41% of ReLEx and 61% of FS-LASIK eyes had an uncorrected distance visual acuity of logMAR ≤ 0.10 at day 1 after surgery, increasing to, respectively, 88% and 69% at 3 months. Mean SE was -0.06 ± 0.35 D 3 months after ReLEx and -0.53 ± 0.60 D after FS-LASIK. The proportion of eyes within ±1.00 D after 3 months was 100% (ReLEx) and 85% (FS-LASIK). For a 6.0-mm pupil, corneal spherical aberrations increased significantly less in ReLEx than FS-LASIK eyes. ReLEx is an all-in-one femtosecond laser refractive procedure, and in this study, results were comparable to FS-LASIK. Refractive predictability and corneal aberrations at 3 months seemed better than or equal to FS-LASIK, whereas visual recovery after ReLEx was slower. © 2012 The Authors. Acta Ophthalmologica © 2012 Acta Ophthalmologica Scandinavica Foundation.
Corneal thickness in dry eyes in an Iraqi population.
Ali, Noora Mauwafak; Hamied, Furkaan M; Farhood, Qasim K
2017-01-01
Dry eye disorder is a multifactorial disease of the tears and ocular surface that results in discomfort and visual disturbance. Corneal pachymetry becomes increasingly important in refractive surgery, for the accurate assessment of intraocular pressure, and in the preoperative assessment of other ocular surgeries. To assess the effect of dry eye disorder on the central corneal thickness (CCT) by comparing with CCT of normal eyes of age-matched individuals. The total number of eyes examined was 280 (140 dry eyes from 70 patients and 140 normal eyes from 70 individuals). Pentacam (Scheimpflug imaging system) was used for measuring the CCT of all eyes. Patients with dry eye syndrome had significantly lower CCT compared to the control group ( P <0.01). Its mean was 536.5 versus 561.3, respectively. CCT of dry eyes was significantly reduced when compared with age- and gender-matched population. This result can be attributed to chronic desiccation by the inflammatory mediators in dry eyes, leading to corneal thinning.
The Advanced Glaucoma Intervention Study (AGIS): 5. Encapsulated bleb after initial trabeculectomy.
Schwartz, A L; Van Veldhuisen, P C; Gaasterland, D E; Ederer, F; Sullivan, E K; Cyrlin, M N
1999-01-01
To compare the incidence of encapsulated bleb after trabeculectomy in eyes with and without previous argon laser trabeculoplasty and to assess other risk factors for encapsulated bleb development. After medical treatment failure, eyes enrolled in the Advanced Glaucoma Intervention Study (AGIS) were randomly assigned to sequences of interventions starting with either argon laser trabeculoplasty or trabeculectomy. In the present study we compared the clinical course for 1 year after trabeculectomy in 119 eyes with failed argon laser trabeculoplasty with that of 379 eyes without previous argon laser trabeculoplasty. Data on bleb encapsulation were collected at the time that the encapsulation was diagnosed, and 3 and 6 months later. Of multiple factors examined in the AGIS data for the risk of developing encapsulated bleb, only male gender and high school graduation without further formal education were statistically significant. Encapsulation occurred in 18.5% of eyes with previous argon laser trabeculoplasty failure and 14.5% of eyes without previous argon laser trabeculoplasty (unadjusted relative risk, 1.27; 95% confidence limits = 0.81, 2.00; P = .23). After adjusting for age, gender, educational achievement, prescribed systemic beta-blockers, diabetes, visual field score, and years since glaucoma diagnosis, this difference remains statistically not significant. Four weeks after trabeculectomy, mean intraocular pressure was 7.5 mm Hg higher in eyes with (22.5 mm Hg) than without (15.0 mm Hg) encapsulated bleb; at 1 year after trabeculectomy and the resumption of medical therapy when needed, this excess was reduced to 1.4 mm Hg. This study, as did two previous studies, found male gender to be a risk factor for bleb encapsulation. Four studies, including the present study, have reported a higher rate of encapsulation in eyes with previous argon laser trabeculoplasty; in two of the studies, one of which was the present study, the rate was not statistically significantly higher; in the other two studies the rate was significantly higher. The 4-week postoperative mean intraocular pressure was higher in eyes with than without encapsulated bleb; with the resumption of medical treatment the two means converged after 1 year.
Topography and Higher Order Corneal Aberrations of the Fellow Eye in Unilateral Keratoconus.
Aksoy, Sibel; Akkaya, Sezen; Özkurt, Yelda; Kurna, Sevda; Açıkalın, Banu; Şengör, Tomris
2017-10-01
Comparison of topography and corneal higher order aberrations (HOA) data of fellow normal eyes of unilateral keratoconus patients with keratoconus eyes and control group. The records of 196 patients with keratoconus were reviewed. Twenty patients were identified as unilateral keratoconus. The best corrected visual acuity (BCVA), topography and aberration data of the unilateral keratoconus patients' normal eyes were compared with their contralateral keratoconus eyes and with control group eyes. For statistical analysis, flat and steep keratometry values, average corneal power, cylindrical power, surface regularity index (SRI), surface asymmetry index (SAI), inferior-superior ratio (I-S), keratoconus prediction index, and elevation-depression power (EDP) and diameter (EDD) topography indices were selected. Mean age of the unilateral keratoconus patients was 26.05±4.73 years and that of the control group was 23.6±8.53 years (p>0.05). There was no statistical difference in BCVA between normal and control eyes (p=0.108), whereas BCVA values were significantly lower in eyes with keratoconus (p=0.001). Comparison of quantitative topographic indices between the groups showed that all indices except the I-S ratio were significantly higher in the normal group than in the control group (p<0.05). The most obvious differences were in the SRI, SAI, EDP, and EDD values. All topographic indices were higher in the keratoconus eyes compared to the normal fellow eyes. There was no difference between normal eyes and the control group in terms of spherical aberration, while coma, trefoil, irregular astigmatism, and total HOA values were higher in the normal eyes of unilateral keratoconus patients (p<0.05). All HOA values were higher in keratoconus eyes than in the control group. According to our study, SRI, SAI, EDP, EDD values, and HOA other than spherical aberration were higher in the clinically and topographically normal fellow eyes of unilateral keratoconus patients when compared to a control group. This finding may be due to the mild asymmetric and morphologic changes in the subclinical stage of keratoconus leading to deterioration in the indicators of corneal irregularity and elevation changes. Therefore, these eyes may be exhibiting the early form of the disease.
Toy, Brian C.; Koo, Euna; Cukras, Catherine; Meyerle, Catherine B.; Chew, Emily Y.; Wong, Wai T.
2015-01-01
Purpose To evaluate the safety and preliminary efficacy of intravitreal ranibizumab for non-neovascular idiopathic macular telangiectasia, type 2 (IMT2). Methods Single-center, open-label phase II clinical trial enrolling 5 participants with bilateral non-neovascular IMT2. Intravitreal ranibizumab (0.5mg) was administered every 4 weeks in the study eye for 12 months with the contralateral eye observed. Outcome measures included changes in: best corrected visual acuity (BCVA), area of late-phase leakage on fluorescein angiography (FA), and retinal thickness on optical coherence tomography (OCT). Results The study treatment was well-tolerated and associated with few adverse events. Change in BCVA at 12 months was not significantly different between treated study eyes (0.0±7.5 letters) and control fellow eyes (+2.2±1.9 letters). However, decreases in the area of late-phase FA leakage (−33±20% for study eyes, +1±8% for fellow eyes) and in OCT central subfield retinal thickness (−11.7±7.0% for study eyes and −2.9±3.5% for fellow eyes) were greater in study eyes compared to fellow eyes. Conclusions Despite significant anatomical responses to treatment, functional improvement in visual acuity was not detected. Intravitreal ranibizumab administered monthly over a time course of 12 months is unlikely to provide a general and significant benefit to patients with non-neovascular IMT2. PMID:22266930
The effect of astigmatism axis on visual acuity.
Mimouni, Michael; Nemet, Achia; Pokroy, Russell; Sela, Tzahi; Munzer, Gur; Kaiserman, Igor
2017-05-11
To evaluate the effect of astigmatism axis on uncorrected distance visual acuity (UDVA) in emmetropic eyes that underwent laser refractive surgery. This retrospective study included patients who underwent laser in situ keratomileusis or photorefractive keratectomy between January 2000 and December 2015 at the Care-Vision Laser Centers, Tel Aviv, Israel. Eyes with a 3-month postoperative spherical equivalent between -0.5 D and 0.5 D were included in this study. Eyes with ocular comorbidities and planned ametropia were excluded. Study eyes were divided into 3 groups according to the steep astigmatic axis: with the rule (WTR) (60-120), oblique (31-59 or 121-149), and against the rule (ATR) (0-30 or 150-180). The UDVA of these 3 groups was compared. The oblique group was divided into oblique ATR and oblique WTR, which were compared with each other. A total of 17,416 consecutive eyes of 8,708 patients were studied. The WTR eyes (n = 10,651) had significantly better UDVA (logMAR 0.01 ± 0.08) than the oblique (n = 3,141, logMAR 0.02 ± 0.09) and ATR eyes (n = 3,624, logMAR 0.02 ± 0.10) (p<0.001). The oblique WTR group had significantly better UDVA than the oblique ATR group (p<0.001). The UDVA of the oblique and ATR groups was similar. Stepwise multiple regression analysis showed that the group accounted for 15% of the UDVA variance (p = 0.04). The astigmatic axis has a small but significant effect on UDVA in emmetropic eyes; WTR was better than oblique and ATR astigmatism. Therefore, when correcting astigmatism, it may be preferable to err towards WTR astigmatism.
Posterior Eye Shape Measurement With Retinal OCT Compared to MRI
Kuo, Anthony N.; Verkicharla, Pavan K.; McNabb, Ryan P.; Cheung, Carol Y.; Hilal, Saima; Farsiu, Sina; Chen, Christopher; Wong, Tien Y.; Ikram, M. Kamran; Cheng, Ching Y.; Young, Terri L.; Saw, Seang M.; Izatt, Joseph A.
2016-01-01
Purpose Posterior eye shape assessment by magnetic resonance imaging (MRI) is used to study myopia. We tested the hypothesis that optical coherence tomography (OCT), as an alternative, could measure posterior eye shape similarly to MRI. Methods Macular spectral-domain OCT and brain MRI images previously acquired as part of the Singapore Epidemiology of Eye Diseases study were analyzed. The right eye in the MRI and OCT images was automatically segmented. Optical coherence tomography segmentations were corrected for optical and display distortions requiring biometry data. The segmentations were fitted to spheres and ellipsoids to obtain the posterior eye radius of curvature (Rc) and asphericity (Qxz). The differences in Rc and Qxz measured by MRI and OCT were tested using paired t-tests. Categorical assignments of prolateness or oblateness using Qxz were compared. Results Fifty-two subjects (67.8 ± 5.6 years old) with spherical equivalent refraction from +0.50 to −5.38 were included. The mean paired difference between MRI and original OCT posterior eye Rc was 24.03 ± 46.49 mm (P = 0.0005). For corrected OCT images, the difference in Rc decreased to −0.23 ± 2.47 mm (P = 0.51). The difference between MRI and OCT asphericity, Qxz, was −0.052 ± 0.343 (P = 0.28). However, categorical agreement was only moderate (κ = 0.50). Conclusions Distortion-corrected OCT measurements of Rc and Qxz were not statistically significantly different from MRI, although the moderate categorical agreement suggests that individual differences remained. This study provides evidence that with distortion correction, noninvasive office-based OCT could potentially be used instead of MRI for the study of posterior eye shape. PMID:27409473
Ghouali, Wajdene; Tahiri Joutei Hassani, Rachid; Djerada, Zoubir; Liang, Hong; El Sanharawi, Mohamed; Labbé, Antoine; Baudouin, Christophe
2017-01-01
To evaluate a possible clinical application of spectral-domain optical coherence tomography (SD-OCT) using en-face module for the imaging of the corneoscleral limbus in normal subjects and dry eye patients. Seventy-six subjects were included in this study. Seventy eyes of 35 consecutive patients with dry eye disease and 82 eyes of 41 healthy control subjects were investigated. All subjects were examined with the Avanti RTVue® anterior segment OCT. En-face OCT images of the corneoscleral limbus were acquired in four quadrants (inferior, superior, nasal and temporal) and then were analyzed semi-quantitatively according to whether or not palisades of Vogt (POV) were visible. En-face OCT images were then compared to in vivo confocal microscopy (IVCM) in eleven eyes of 7 healthy and dry eye patients. En-face SD-OCT showed POV as a radially oriented network, located in superficial corneoscleral limbus, with a good correlation with IVCM features. It provided an easy and reproducible identification of POV without any special preparation or any direct contact, with a grading scale from 0 (no visualization) to 3 (high visualization). The POV were found predominantly in superior (P<0.001) and inferior (P<0.001) quadrants when compared to the nasal and temporal quadrants for all subjects examined. The visibility score decreased with age (P<0.001) and was lower in dry eye patients (P<0.01). In addition, the score decreased in accordance with the severity of dry eye disease (P<0.001). En-face SD-OCT is a non-contact imaging technique that can be used to evaluate the POV, thus providing valuable information about differences in the limbal anatomy of dry eye patients as compared to healthy patients.
Rao, Harsha L; Kumbar, Tukaram; Addepalli, Uday K; Bharti, Neha; Senthil, Sirisha; Choudhari, Nikhil S; Garudadri, Chandra S
2012-02-29
To evaluate the influence of a control group on the diagnostic accuracy of spectral-domain optical coherence tomography (SD-OCT) in early glaucoma. In a diagnostic, case-control study, 119 eyes of 60 normal subjects with no findings suspicious for glaucoma (control cohort 1); 76 eyes of 41 subjects referred by general ophthalmologists as glaucoma suspects based on optic disc morphology, but found by glaucoma experts to be normal but with physiological variations in their optic nerves (control cohort 2); and 65 eyes of 46 early-glaucoma patients (cases) underwent imaging of the optic nerve head (ONH), retinal nerve fiber layer (RNFL), and ganglion cell complex (GCC) by SD-OCT. Areas under the receiver operating characteristic curves (AUC) of ONH parameters discriminating glaucomatous eyes from normal eyes of control cohort 2 were significantly lesser (P < 0.001) than those discriminating glaucomatous eyes from normal eyes of control cohort 1. AUCs of RNFL parameters discriminating glaucomatous eyes from normal eyes of control cohorts 2 and 1 were comparable. Although the AUCs of GCC thickness parameters were comparable, AUCs of GCC focal and global loss volume in control cohort 2 (0.684 and 0.671. respectively) were significantly less (P < 0.05) than in control cohort 1 (0.881 and 0.841, respectively). The effectiveness of most SD-OCT parameters in detecting glaucoma significantly decreased when evaluated against a clinically relevant control group with suspicious-looking optic nerves compared with that against a control group consisting of normal subjects with no findings suspicious for glaucoma.
Impact of Glaucoma and Dry Eye on Text-Based Searching.
Sun, Michelle J; Rubin, Gary S; Akpek, Esen K; Ramulu, Pradeep Y
2017-06-01
We determine if visual field loss from glaucoma and/or measures of dry eye severity are associated with difficulty searching, as judged by slower search times on a text-based search task. Glaucoma patients with bilateral visual field (VF) loss, patients with clinically significant dry eye, and normally-sighted controls were enrolled from the Wilmer Eye Institute clinics. Subjects searched three Yellow Pages excerpts for a specific phone number, and search time was recorded. A total of 50 glaucoma subjects, 40 dry eye subjects, and 45 controls completed study procedures. On average, glaucoma patients exhibited 57% longer search times compared to controls (95% confidence interval [CI], 26%-96%, P < 0.001), and longer search times were noted among subjects with greater VF loss ( P < 0.001), worse contrast sensitivity ( P < 0.001), and worse visual acuity ( P = 0.026). Dry eye subjects demonstrated similar search times compared to controls, though worse Ocular Surface Disease Index (OSDI) vision-related subscores were associated with longer search times ( P < 0.01). Search times showed no association with OSDI symptom subscores ( P = 0.20) or objective measures of dry eye ( P > 0.08 for Schirmer's testing without anesthesia, corneal fluorescein staining, and tear film breakup time). Text-based visual search is slower for glaucoma patients with greater levels of VF loss and dry eye patients with greater self-reported visual difficulty, and these difficulties may contribute to decreased quality of life in these groups. Visual search is impaired in glaucoma and dry eye groups compared to controls, highlighting the need for compensatory strategies and tools to assist individuals in overcoming their deficiencies.
Kim, Kyung Min; Kim, Jae Hui; Chang, Young Suk; Kim, Jong Woo; Kim, Chul Gu
2018-01-01
To evaluate long-term changes in visual acuity and retinal microstructure in patients with neovascular age-related macular degeneration (AMD) who had maintained dry macula after initial treatment. This retrospective observational study included 55 eyes that were diagnosed with neovascular AMD, were treated with three monthly ranibizumab injections, and maintained dry macula during a two-year follow-up. Best-corrected visual acuity (BCVA) at three months and at the final follow-up were compared, and the degree of visual improvement was compared between eyes with and without improvement of the ellipsoid zone. In addition, the incidence of improvement of the ellipsoid zone was compared between eyes with different extents of disruption. The mean follow-up period was 30.3 ± 4.1 months. BCVA at three months and at the final follow-up was 0.51 ± 0.46 and 0.45 ± 0.49 (P<0.001). Among 35 eyes that exhibited >200 μm of disruption of the ellipsoid zone, 15 (42.9%) showed improvement of the ellipsoid zone, and the improvement in BCVA was greater in these eyes than that in the remaining 20 eyes (P=0.021). A higher incidence of improvement of the ellipsoid zone was noted in eyes with 200 to 800 μm of disruption than in eyes with >800 μm of disruption (P<0.001). Long-term improvement in visual acuity was noted in eyes that had maintained dry macula after three ranibizumab injections. The status of the ellipsoid zone at three months was closely associated with visual improvement.
Rates of retinal nerve fiber layer thinning in glaucoma suspect eyes
Miki, Atsuya; Medeiros, Felipe A.; Weinreb, Robert N.; Jain, Sonia; He, Feng; Sharpsten, Lucie; Khachatryan, Naira; Hammel, Na’ama; Liebmann, Jeffrey M.; Girkin, Christopher A.; Sample, Pamela A.; Zangwill, Linda M.
2015-01-01
Purpose To compare the rates of retinal nerve fiber layer (RNFL) loss in patients suspect of having glaucoma who developed visual field damage (VFD) to those who did not develop VFD, and to determine whether the rate of RNFL loss can be used to predict who will develop VFD.. Design Prospective observational cohort study Participants Glaucoma suspects, defined as having glaucomatous optic neuropathy or ocular hypertension (Intraocular pressure (IOP)>21 mmHg) without repeatable VFD at baseline from the Diagnostic Innovations in Glaucoma Study, and the African Descent and Glaucoma Evaluation Study. Methods Global and quadrant RNFL thickness (RNFLT) were measured with the Spectralis spectral-domain optical coherence tomography (SD-OCT). VFD was defined as having 3 consecutive abnormal visual fields. The rate of RNFL loss in eyes developing VFD was compared with eyes not developing VFD using multivariable linear mixed-effects models. A joint longitudinal survival model utilized the estimated RNFLT slope to predict the risk of developing VFD, while adjusting for potential confounding variables. Main Outcome Measures The rate of RNFL thinning and the probability of developing VFD. Results Four hundred and fifty-four eyes of 294 glaucoma suspects were included. The average number of SD-OCT examinations was 4.6 (range, 2–9) with median follow-up time of 2.2 (0.4–4.1) years. Forty eyes (8.8%) developed VFD. The estimated mean rate of global RNFL loss was significantly faster in eyes developing VFD compared with eyes that did not (−2.02μm/year vs. −0.82μm/year, P<0.001). The joint longitudinal survival model showed that each 1μm/year faster rate of global RNFL loss corresponded to a 2.05 times higher risk of developing VFD (Hazards Ratio (HR)=2.05, 95% Confidence Interval (CI): 1.14–3.71; p=0.017). Conclusions The rate of global RNFL loss was more than twice as fast in eyes developing VFD compared with eyes that did not develop them. Joint longitudinal survival model showed that a 1μm/year faster rate of RNFLT loss corresponded to a 2.05 times higher risk of developing VFD. These results suggest that measuring the rate of SD-OCT RNFL loss may be a useful tool to help identify patients who are at a high risk of developing visual field loss. PMID:24629619
Changes in tear volume and ocular symptoms of patients receiving oral anticancer drug S-1.
Kuriki, Reiko; Hata, Tsuyoshi; Nakayama, Kinuyo; Ito, Yuichi; Misawa, Kazunari; Ito, Seiji; Tatematsu, Michiko; Kaneda, Norio
2018-01-01
Most eye disorders are not fatal but may deteriorate the quality of life of a patient. The eye disorder that is most frequently reported in the cancer chemotherapy is associated with the combination of tegafur/gimeracil/potassium oxonate (S-1). However, preventive methods or treatment methods for the eye disorder have not yet been established. This study aimed to determine changes in tear volume and subjective ocular symptoms during the treatment period in patients receiving S-1 monotherapy for early detection of adverse effects in the eye and establishment of its treatment methods. This study included eleven patients receiving S-1 monotherapy as a postoperative adjuvant chemotherapy for gastric cancer. Six subjective ocular symptoms including watering eyes were evaluated and changes in tear volume measured by the Schirmer's test in patients receiving S-1 during the treatment period. In the present study, the patients were divided into "no watering eyes" (patients not experienced watering eyes) group and "watering eyes" (patients experienced watering eyes even once) group. Six out of eleven patients developed watering eyes after receiving S-1 monotherapy. Among these, the earliest onset occurred on the 2nd week after oral administration. Watering eyes and eye discharge were highly related in patients having a trouble in daily life due to the decreased QOL. Changes in tear volume in the "watering eyes" group significantly increased compared to the "no watering eyes" group during the treatment period, especially when the patients had no subjective symptom of the increased tear volume. It is essential to prevent eye disorders including watering eyes as an adverse effect of S-1 administration. The present study recommends that the tear volume should be periodically measured using Schirmer's test, and the patient should be interviewed regarding the subjective ocular symptoms for the early detection of watering eyes caused by S-1 administration. If the tear volume can not be measured periodically, medical staffs should pay attention to the patient with eye discharge.
Ocular Vestibular Evoked Myogenic Potentials in Response to Three Test Positions and Two Frequencies
Todai, Janvi K.; Congdon, Sharon L.; Sangi-Haghpeykar, Haleh; Cohen, Helen S.
2014-01-01
Objective To determine how eye closure, test positions, and stimulus frequencies influence ocular vestibular evoked myogenic potentials. Study Design This study used a within-subjects repeated measures design. Methods Twenty asymptomatic subjects were each tested on ocular vestibular evoked myogenic potentials in three head/eye conditions at 500 Hz and 1000 Hz using air-conducted sound: 1) Sitting upright, head erect, eyes open, looking up. 2) Lying supine, neck flexed 30 degrees, eyes open and looking up. 3) Lying supine, neck flexed 30 degrees, eyes closed and relaxed. Four dependent variables measured were n10, p16, amplitude, and threshold. Results The supine position/ eyes open was comparable to sitting/ eyes open and better than supine/ eyes closed. Eyes closed resulted in lower amplitude, higher threshold, and prolonged latency. Significantly fewer subjects provided responses with eyes closed than with eyes open. No significant differences were found between both eyes open conditions. Both n10 and p16 were lower at 1000 Hz than at 500 Hz. Amplitude and threshold were higher at 1000 Hz than at 500 Hz. Conclusion Supine eyes open is a reliable alternative to sitting eyes open in patients who cannot maintain a seated position. Testing at 1000 Hz provides a larger response with a faster onset that fatigues faster than at 500 Hz. The increased variability and decreased response in the eyes closed position suggest that the eyes closed position is not reliable. PMID:24178911
DOE Office of Scientific and Technical Information (OSTI.GOV)
Power, S.; Mirza, M.; Thakorlal, A.
PurposeThis prospective pilot study was undertaken to evaluate the feasibility and effectiveness of using a radiation absorbing shield to reduce operator dose from scatter during lower limb endovascular procedures.Materials and MethodsA commercially available bismuth shield system (RADPAD) was used. Sixty consecutive patients undergoing lower limb angioplasty were included. Thirty procedures were performed without the RADPAD (control group) and thirty with the RADPAD (study group). Two separate methods were used to measure dose to a single operator. Thermoluminescent dosimeter (TLD) badges were used to measure hand, eye, and unshielded body dose. A direct dosimeter with digital readout was also used tomore » measure eye and unshielded body dose. To allow for variation between control and study groups, dose per unit time was calculated.ResultsTLD results demonstrated a significant reduction in median body dose per unit time for the study group compared with controls (p = 0.001), corresponding to a mean dose reduction rate of 65 %. Median eye and hand dose per unit time were also reduced in the study group compared with control group, however, this was not statistically significant (p = 0.081 for eye, p = 0.628 for hand). Direct dosimeter readings also showed statistically significant reduction in median unshielded body dose rate for the study group compared with controls (p = 0.037). Eye dose rate was reduced for the study group but this was not statistically significant (p = 0.142).ConclusionInitial results are encouraging. Use of the shield resulted in a statistically significant reduction in unshielded dose to the operator’s body. Measured dose to the eye and hand of operator were also reduced but did not reach statistical significance in this pilot study.« less
Johnstone, Nancy; Ward, Daniel A
2005-01-01
The objective of this retrospective study was to report the incidence of posterior capsule disruption during routine phacoemulsification and to document the postoperative outcomes and complications in eyes with posterior capsule disruption compared with eyes with intact posterior capsules. Records of 143 dogs (244 eyes) were reviewed. Data collected included whether the posterior capsule was disrupted, whether the disruption was planned or accidental, whether an intraocular lens was implanted, and visual outcome. Records were reviewed for postoperative complications. Intraocular lens implantation rates, complication rates, and visual outcomes were compared between intact and disrupted posterior capsule groups using Chi-square analyses. The posterior capsule was disrupted in 33/244 eyes (14%). Planned capsulotomies accounted for 36% of the disruptions. Intraocular lenses were implanted in 76% of eyes without a disruption of the posterior capsule and in 31% of eyes with a posterior capsule disruption. Intraocular lenses were more likely to be implanted in eyes with a planned disruption of the posterior capsule (7/12; 58%) than in eyes with an accidental disruption (3/20; 15%). There were no significant differences in postoperative complications or visual outcome between eyes with posterior capsule disruption and those without. The most significant complication of posterior capsule disruption during phacoemulsification is the inability to implant an intraocular lens. Intraocular lenses are more likely to be placed in eyes with intentional disruptions of the posterior capsule than those with accidental ruptures.
Fernández, Gerardo; Sapognikoff, Marcelo; Guinjoan, Salvador; Orozco, David; Agamennoni, Osvaldo
2016-07-01
The current study analyze the effect of word properties (i.e., word length, word frequency and word predictability) on the eye movement behavior of patients with schizophrenia (SZ) compared to age-matched controls. 18 SZ patients and 40 age matched controls participated in the study. Eye movements were recorded during reading regular sentences by using the eyetracking technique. Eye movement analyses were performed using linear mixed models. Analysis of eye movements revealed that patients with SZ decreased the amount of single fixations, increased their total number of second pass fixations compared with healthy individuals (Controls). In addition, SZ patients showed an increase in gaze duration, compared to Controls. Interestingly, the effects of current word frequency and current word length processing were similar in Controls and SZ patients. The high rate of second pass fixations and its low rate in single fixation might reveal impairments in working memory when integrating neighbor words. In contrast, word frequency and length processing might require less complex mechanisms, which were functioning in SZ patients. To the best of our knowledge, this is the first study measuring how patients with SZ process dynamically well-defined words embedded in regular sentences. The findings suggest that evaluation of the resulting changes in eye movement behavior may supplement current symptom-based diagnosis. Copyright © 2016 Elsevier Inc. All rights reserved.
Final visual acuity results in the early treatment for retinopathy of prematurity study.
Good, William V; Hardy, Robert J; Dobson, Velma; Palmer, Earl A; Phelps, Dale L; Tung, Betty; Redford, Maryann
2010-06-01
To compare visual acuity at 6 years of age in eyes that received early treatment for high-risk prethreshold retinopathy of prematurity (ROP) with conventionally managed eyes. Infants with symmetrical, high-risk prethreshold ROP (n = 317) had one eye randomized to earlier treatment at high-risk prethreshold disease and the other eye managed conventionally, treated if ROP progressed to threshold severity. For asymmetric cases (n = 84), the high-risk prethreshold eye was randomized to either early treatment or conventional management. The main outcome measure was ETDRS visual acuity measured at 6 years of age by masked testers. Retinal structure was assessed as a secondary outcome. Analysis of all subjects with high-risk prethreshold ROP showed no statistically significant benefit for early treatment (24.3% vs 28.6% [corrected] unfavorable outcome; P = .15). Analysis of 6-year visual acuity results according to the Type 1 and 2 clinical algorithm showed a benefit for Type 1 eyes (25.1% vs 32.8%; P = .02) treated early but not Type 2 eyes (23.6% vs 19.4%; P = .37). Early-treated eyes showed a significantly better structural outcome compared with conventionally managed eyes (8.9% vs 15.2% unfavorable outcome; P < .001), with no greater risk of ocular complications. Early treatment for Type 1 high-risk prethreshold eyes improved visual acuity outcomes at 6 years of age. Early treatment for Type 2 high-risk prethreshold eyes did not. Application to Clinical Practice Type 1 eyes, not Type 2 eyes, should be treated early. These results are particularly important considering that 52% of Type 2 high-risk prethreshold eyes underwent regression of ROP without requiring treatment. Trial Registration clinicaltrials.gov Identifier: NCT00027222.
Do, Diana V; Schmidt-Erfurth, Ursula; Gonzalez, Victor H; Gordon, Carmelina M; Tolentino, Michael; Berliner, Alyson J; Vitti, Robert; Rückert, Rene; Sandbrink, Rupert; Stein, David; Yang, Ke; Beckmann, Karola; Heier, Jeff S
2011-09-01
To determine whether different doses and dosing regimens of intravitreal vascular endothelial growth factor (VEGF) Trap-Eye are superior to focal/grid photocoagulation in eyes with diabetic macular edema (DME). Multicenter, randomized, double-masked, phase 2 clinical trial. A total of 221 diabetic patients with clinically significant macular edema involving the central macula. Patients were assigned to 1 of 5 treatment regimens: 0.5 mg VEGF Trap-Eye every 4 weeks; 2 mg VEGF Trap-Eye every 4 weeks; 2 mg VEGF Trap-Eye for 3 initial monthly doses and then every 8 weeks; 2 mg VEGF Trap-Eye for 3 initial monthly doses and then on an as-needed (PRN) basis; or macular laser photocoagulation. Assessments were completed at baseline and every 4 weeks thereafter. Mean change in visual acuity and central retinal thickness (CRT) at 24 weeks. Patients in the 4 VEGF Trap-Eye groups experienced mean visual acuity benefits ranging from +8.5 to +11.4 Early Treatment of Diabetic Retinopathy Study (ETDRS) letters versus only +2.5 letters in the laser group (P ≤ 0.0085 for each VEGF Trap-Eye group vs. laser). Gains from baseline of 0+, 10+, and 15+ letters were seen in up to 93%, 64%, and 34% of VEGF Trap-Eye groups versus up to 68%, 32%, and 21% in the laser group, respectively. Mean reductions in CRT in the 4 VEGF Trap-Eye groups ranged from -127.3 to -194.5 μm compared with only -67.9 μm in the laser group (P = 0.0066 for each VEGF Trap-Eye group vs. laser). VEGF Trap-Eye was generally well tolerated. Ocular adverse events in patients treated with VEGF Trap-Eye were generally consistent with those seen with other intravitreal anti-VEGF agents. Intravitreal VEGF Trap-Eye produced a statistically significant and clinically relevant improvement in visual acuity when compared with macular laser photocoagulation in patients with DME. Copyright © 2011 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Boynton, Grace E; Raoof, Duna; Niziol, Leslie M; Hussain, Munira; Mian, Shahzad I
2015-07-01
To evaluate the safety and efficacy of topical loteprednol etabonate (LE) 0.5% compared with cyclosporine A (CsA) 0.05% for the prophylaxis and treatment of dry eye syndrome (DES) after hematopoietic stem cell transplantation (HSCT). Seventy-five patients were randomized to LE (n = 76 eyes of 38 patients) or CsA (n = 74 eyes of 37 patients) pre-HSCT. Lissamine green and fluorescein staining, tear break-up time, tear osmolarity (Osm), Schirmer score (Sch), intraocular pressure, visual acuity, and Ocular Surface Disease Index were assessed pre-HSCT, 3, 6, 9, and 12 months post-HSCT. There were no differences in DES incidence (P = 0.22; log-rank test) or progression (P = 0.41; log-rank test) between the 2 treatment arms during the course of the study. Among eyes with no DES at enrollment, the Kaplan-Meier analysis yielded a 90% rate of DES development in cyclosporine-treated eyes and a 79% rate of DES development in LE-treated eyes by 12 months post-HSCT. The Kaplan-Meier analysis of eyes with DES at enrollment demonstrated a 38% rate of disease progression among cyclosporine-treated eyes and a 26% rate of disease progression among loteprednol-treated eyes by 12 months. No patient in either group had an elevation of 10 mm Hg or greater from baseline at any study visit, and no patients had their treatment discontinued for elevation in intraocular pressure. Pre-HSCT initiation of LE 0.5% appears to be safe and may be as effective as CsA 0.5% for the treatment and prophylaxis of DES following HSCT.
Improving data retention in EEG research with children using child-centered eye tracking
Maguire, Mandy J.; Magnon, Grant; Fitzhugh, Anna E.
2014-01-01
Background Event Related Potentials (ERPs) elicited by visual stimuli have increased our understanding of developmental disorders and adult cognitive abilities for decades; however, these studies are very difficult with populations who cannot sustain visual attention such as infants and young children. Current methods for studying such populations include requiring a button response, which may be impossible for some participants, and experimenter monitoring, which is subject to error, highly variable, and spatially imprecise. New Method We developed a child-centered methodology to integrate EEG data acquisition and eye-tracking technologies that uses “attention-getters” in which stimulus display is contingent upon the child’s gaze. The goal was to increase the number of trials retained. Additionally, we used the eye-tracker to categorize and analyze the EEG data based on gaze to specific areas of the visual display, compared to analyzing based on stimulus presentation. Results Compared with Existing Methods The number of trials retained was substantially improved using the child-centered methodology compared to a button-press response in 7–8 year olds. In contrast, analyzing the EEG based on eye gaze to specific points within the visual display as opposed to stimulus presentation provided too few trials for reliable interpretation. Conclusions By using the linked EEG-eye-tracker we significantly increased data retention. With this method, studies can be completed with fewer participants and a wider range of populations. However, caution should be used when epoching based on participants’ eye gaze because, in this case, this technique provided substantially fewer trials. PMID:25251555
Rodanant, Nuttawut; Friberg, Thomas R; Cheng, Lingyun; Aurora, Ajay; Bartsch, Dirk; Toyoguchi, Mitsuko; Corbin, Patricia S; El-Bradey, Mohamed H; Freeman, William R
2002-10-01
To determine the predictors of drusen reduction in eyes with nonexudative age-related macular degeneration (ARMD) treated with subthreshold infrared (810 nm) diode laser macular grid photocoagulation. Additionally, to determine the relationship of laser-induced drusen reduction and best-corrected visual acuity (BCVA) 18 months after laser treatment. Randomized controlled clinical trial. Fifty patients (100 eyes) with bilateral nonexudative ARMD were enrolled at two centers. One eye of each patient was randomized to the observation; the other eye was treated with 48 subthreshold (invisible end point) applications of infrared (810 nm) diode laser in a macular grid pattern. The eyes that received subthreshold laser treatment were compared with the eyes that received no treatment. The baseline fundus characteristics (number, size, and distribution of drusen, as well as focal hyperpigmentation) from two macula areas (central 1500 micro diameter, pericentral 1500 micro ring area) on stereo color photographs, the number of laser-induced lesions, and the area of laser induced retinal pigment epithelial (RPE) lesions on fluorescein angiography 3 months after treatment were studied as predictors of major drusen reduction (> or = 50% drusen reduction from baseline) 18 months after laser treatment. BCVA at baseline and 18 months later was compared in observation eyes and in laser-treated eyes. Eighteen months after randomization, 24 (48%) of 50 eyes treated with subthreshold laser had major drusen reduction compared with three (6%) of 50 observation eyes (P =.00001). At 3 months post-treatment in laser-treated eyes with major drusen reduction, the mean number of laser-induced lesions on fluorescein angiography was 30.7 and the mean area of RPE change was 0.81 mm(2) compared with 14.8 laser-induced lesions and 0.35 mm(2) area of RPE change in eyes without major drusen reduction (P =.0001 and P =.0003, respectively). At baseline, fundus characteristics were not significantly different between observation eyes and laser-treated eyes or between the major drusen reduction group and the nonmajor drusen reduction group. At 18 months after treatment, BCVA was not significantly different in laser-treated eyes and in observation eyes. Subthreshold infrared (810 nm) diode laser macular grid photocoagulation in eyes with nonexudative ARMD significantly reduced drusen 18 months after laser treatment. Both the number of subthreshold laser lesions and the area of RPE changes visible on fluorescein angiography 3 months after treatment appeared to be predictors for major drusen reduction 18 months after treatment. However, it remains to be determined whether laser-induced drusen reduction is beneficial for visual acuity or reduces the incidence of choroidal neovascularization (CNV) in eyes with nonexudative ARMD.
Eye shape and the nocturnal bottleneck of mammals.
Hall, Margaret I; Kamilar, Jason M; Kirk, E Christopher
2012-12-22
Most vertebrate groups exhibit eye shapes that vary predictably with activity pattern. Nocturnal vertebrates typically have large corneas relative to eye size as an adaptation for increased visual sensitivity. Conversely, diurnal vertebrates generally demonstrate smaller corneas relative to eye size as an adaptation for increased visual acuity. By contrast, several studies have concluded that many mammals exhibit typical nocturnal eye shapes, regardless of activity pattern. However, a recent study has argued that new statistical methods allow eye shape to accurately predict activity patterns of mammals, including cathemeral species (animals that are equally likely to be awake and active at any time of day or night). Here, we conduct a detailed analysis of eye shape and activity pattern in mammals, using a broad comparative sample of 266 species. We find that the eye shapes of cathemeral mammals completely overlap with nocturnal and diurnal species. Additionally, most diurnal and cathemeral mammals have eye shapes that are most similar to those of nocturnal birds and lizards. The only mammalian clade that diverges from this pattern is anthropoids, which have convergently evolved eye shapes similar to those of diurnal birds and lizards. Our results provide additional evidence for a nocturnal 'bottleneck' in the early evolution of crown mammals.
Eye shape and the nocturnal bottleneck of mammals
Hall, Margaret I.; Kamilar, Jason M.; Kirk, E. Christopher
2012-01-01
Most vertebrate groups exhibit eye shapes that vary predictably with activity pattern. Nocturnal vertebrates typically have large corneas relative to eye size as an adaptation for increased visual sensitivity. Conversely, diurnal vertebrates generally demonstrate smaller corneas relative to eye size as an adaptation for increased visual acuity. By contrast, several studies have concluded that many mammals exhibit typical nocturnal eye shapes, regardless of activity pattern. However, a recent study has argued that new statistical methods allow eye shape to accurately predict activity patterns of mammals, including cathemeral species (animals that are equally likely to be awake and active at any time of day or night). Here, we conduct a detailed analysis of eye shape and activity pattern in mammals, using a broad comparative sample of 266 species. We find that the eye shapes of cathemeral mammals completely overlap with nocturnal and diurnal species. Additionally, most diurnal and cathemeral mammals have eye shapes that are most similar to those of nocturnal birds and lizards. The only mammalian clade that diverges from this pattern is anthropoids, which have convergently evolved eye shapes similar to those of diurnal birds and lizards. Our results provide additional evidence for a nocturnal ‘bottleneck’ in the early evolution of crown mammals. PMID:23097513
Tutorial on Biostatistics: Linear Regression Analysis of Continuous Correlated Eye Data.
Ying, Gui-Shuang; Maguire, Maureen G; Glynn, Robert; Rosner, Bernard
2017-04-01
To describe and demonstrate appropriate linear regression methods for analyzing correlated continuous eye data. We describe several approaches to regression analysis involving both eyes, including mixed effects and marginal models under various covariance structures to account for inter-eye correlation. We demonstrate, with SAS statistical software, applications in a study comparing baseline refractive error between one eye with choroidal neovascularization (CNV) and the unaffected fellow eye, and in a study determining factors associated with visual field in the elderly. When refractive error from both eyes were analyzed with standard linear regression without accounting for inter-eye correlation (adjusting for demographic and ocular covariates), the difference between eyes with CNV and fellow eyes was 0.15 diopters (D; 95% confidence interval, CI -0.03 to 0.32D, p = 0.10). Using a mixed effects model or a marginal model, the estimated difference was the same but with narrower 95% CI (0.01 to 0.28D, p = 0.03). Standard regression for visual field data from both eyes provided biased estimates of standard error (generally underestimated) and smaller p-values, while analysis of the worse eye provided larger p-values than mixed effects models and marginal models. In research involving both eyes, ignoring inter-eye correlation can lead to invalid inferences. Analysis using only right or left eyes is valid, but decreases power. Worse-eye analysis can provide less power and biased estimates of effect. Mixed effects or marginal models using the eye as the unit of analysis should be used to appropriately account for inter-eye correlation and maximize power and precision.
Chan, Tommy C Y; Ye, Cong; Chan, Kwok Ping; Chu, Kai On; Jhanji, Vishal
2016-09-01
To evaluate the performance of a point-of-care test for detection of matrix metalloproteinase 9 (MMP-9) levels in post-laser-assisted in situ keratomileusis (LASIK) dry eyes. A comparative study between patients with mild to moderate post-LASIK dry eyes and age-matched normal subjects was conducted. Ocular surface disease index (OSDI), tear break-up time (TBUT), and tear film MMP-9 and total protein levels were compared between the two groups. A point-of-care test device (RPS InflammaDry, Sarasota, Florida, USA) was utilised to confirm elevated MMP-9 levels in tear film. Fourteen post-LASIK dry eyes and 34 normal eyes were included. There was no significant difference in age and gender between both groups (p>0.175). The OSDI was significantly higher (25.5±7.7 vs 7.4±2.5; p<0.001) and TBUT levels were significantly lower (5.4±0.9 vs 13.5±2.3; p<0.001) in patients with dry eye compared with normal subjects. The tear film MMP-9 levels were 52.7±32.5 ng/mL in dry eyes and 4.1±2.1 ng/mL in normal eyes (p<0.001). MMP-9 levels were >40 ng/mL in 7/14 (50.0%) post-LASIK dry eyes. The InflammaDry was positive in 8/14 (57.1%) post-LASIK eyes. All positive cases had tear film MMP-9 levels ≥38.03 ng/mL. Agreement between InflammaDry and MMP-9 was excellent with Cohen κ value of 0.857 in post-LASIK dry eyes. Only half of post-LASIK dry eyes were found to have significant inflammation associated with elevated MMP-9. The OSDI is useful to non-specifically identify patients with symptomatic dry eye while the InflammaDry determined which patients with dry eye were associated with significant inflammation that may guide therapeutic management decisions. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Optical Coherence Tomography Angiography in Optic Disc Swelling.
Fard, Masoud Aghsaei; Jalili, Jalil; Sahraiyan, Alireza; Khojasteh, Hassan; Hejazi, Marjane; Ritch, Robert; Subramanian, Prem S
2018-05-04
To compare optical coherence tomography angiography (OCT-A) of peripapillary total vasculature and capillaries in patients with optic disc swelling. Cross-sectional study. Twenty nine eyes with acute nonarteritic anterior ischemic optic neuropathy (NAION), 44 eyes with papilledema, 8 eyes with acute optic neuritis, and 48 eyes of normal subjects were imaged using OCT-A. Peripapillary total vasculature information was recorded using a commercial vessel density map. Customized image analysis with major vessel removal was also used to measure whole-image capillary density and peripapillary capillary density (PCD). Mixed models showed that the peripapillary total vasculature density values were significantly lower in NAION eyes, followed by papilledema eyes and control eyes, using commercial software (P < .0001 for all comparisons). The customized software also showed significantly lower PCD of NAION eyes compared with papilledema eyes (all P < .001), but did not show significant differences between papilledema and control subjects. Our software showed significantly lower whole image and PCD in eyes with optic neuritis than papilledema. There was no significant difference between NAION and optic neuritis using our software. The area under the receiver operating curves for discriminating NAION from papilledema eyes and optic neuritis from papilledema eyes was highest for whole-image capillary density (0.94 and 0.80, respectively) with our software, followed by peripapillary total vasculature (0.9 and 0.74, respectively ) with commercial software. OCT-A is helpful to distinguish NAION and papillitis from papilledema. Whole-image capillary density had the greatest diagnostic accuracy for differentiating disc swelling. Copyright © 2018 Elsevier Inc. All rights reserved.
Zou, Leilei; Liu, Rui; Zhang, Xiaohui; Chu, Renyuan; Dai, Jinhui; Zhou, Hao
2014-01-01
Purpose Scleral remodeling is an important mechanism underlying the development of myopia. Atropine, an antagonist of G protein-coupled muscarinic receptors, is currently used as an off-label treatment for myopia. Regulator of G-protein signaling 2 (RGS2) functions as an intracellular selective inhibitor of muscarinic receptors. In this study we measured scleral RGS2 expression and scleral remodeling in an animal model of myopia in the presence or absence of atropine treatment. Methods Guinea pigs were assigned to four groups: normal (free of form deprivation), form deprivation myopia (FDM) for 4 weeks, FDM treated with saline, and FDM treated with atropine. Biometric measurements were then performed. RGS2 expression levels and scleral remodeling, including scleral thickness and collagen type I expression, were compared among the four groups. Results Compared with normal eyes and contralateral control eyes, the FDM eyes had the most prominent changes in refraction, axial length, and scleral remodeling, indicating myopia. There was no significant difference between control and normal eyes. Hematoxylin and eosin staining showed that the scleral thickness was significantly thinner in the posterior pole region of FDM eyes compared to normal eyes. Real-time PCR and western blot analysis showed a significant decrease in posterior scleral collagen type I mRNA and protein expression in the FDM eyes compared to the normal eyes. The FDM eyes also had increased levels of RGS2 mRNA and protein expression in the sclera. Atropine treatment attenuated the FDM-induced changes in refraction, axial length, and scleral remodeling. Interestingly, atropine treatment significantly increased collagen type I mRNA expression but decreased RGS2 mRNA and protein expression in the sclera of the FDM eyes. Conclusions We identified a significant RGS2 upregulation and collagen type I downregulation in the sclera of FDM eyes, which could be partially attenuated by atropine treatment. Our data suggest that targeting dysregulated RGS2 may provide a novel strategy for development of therapeutic agents to suppress myopia progression. PMID:25018620
Miyata, Hiromitsu; Minagawa-Kawai, Yasuyo; Watanabe, Shigeru; Sasaki, Toyofumi; Ueda, Kazuhiro
2012-01-01
Background A growing body of evidence suggests that meditative training enhances perception and cognition. In Japan, the Park-Sasaki method of speed-reading involves organized visual training while forming both a relaxed and concentrated state of mind, as in meditation. The present study examined relationships between reading speed, sentence comprehension, and eye movements while reading short Japanese novels. In addition to normal untrained readers, three middle-level trainees and one high-level expert on this method were included for the two case studies. Methodology/Principal Findings In Study 1, three of 17 participants were middle-level trainees on the speed-reading method. Immediately after reading each story once on a computer monitor, participants answered true or false questions regarding the content of the novel. Eye movements while reading were recorded using an eye-tracking system. Results revealed higher reading speed and lower comprehension scores in the trainees than in the untrained participants. Furthermore, eye-tracking data by untrained participants revealed multiple correlations between reading speed, accuracy and eye-movement measures, with faster readers showing shorter fixation durations and larger saccades in X than slower readers. In Study 2, participants included a high-level expert and 14 untrained students. The expert showed higher reading speed and statistically comparable, although numerically lower, comprehension scores compared with the untrained participants. During test sessions this expert moved her eyes along a nearly straight horizontal line as a first pass, without moving her eyes over the whole sentence display as did the untrained students. Conclusions/Significance In addition to revealing correlations between speed, comprehension and eye movements in reading Japanese contemporary novels by untrained readers, we describe cases of speed-reading trainees regarding relationships between these variables. The trainees overall tended to show poor performance influenced by the speed-accuracy trade-off, although this trade-off may be reduced in the case of at least one high-level expert. PMID:22590519
A Case of Uveal Colobomas Showing Marked Left-Right Difference in Diabetic Retinopathy.
Moriya, Takeshi; Ochi, Ryosuke; Imagawa, Yukihiro; Sato, Bumpei; Morishita, Seita; Tonari, Masahiro; Fukumoto, Masanori; Suzuki, Hiroyuki; Kobayashi, Takatoshi; Kida, Teruyo; Ikeda, Tsunehiko
2016-01-01
Congenital uveal colobomas, including inferior iris and choroidal colobomas, are associated with microcornea and microphthalmia and often show left-right differences (laterality). The purpose of this study was to report a case of choroidal coloboma associated with left-right differences in diabetic retinopathy (DR). This study reports a 59-year-old male with bilateral iris and choroidal colobomas. The colobomatous area in the patient's right eye extended to the macula, and his right eye had been amblyopic since birth. The colobomatous area in his left eye was less extensive and did not involve the macula. Examination of the patient's left eye revealed multiple hemorrhages and hard exudates in the macula due to DR, but examination of his right eye showed almost no changes in DR, thus revealing a marked left-right difference. Optical coherence tomography showed more extensive retinal thinning in the patient's right eye than in his left eye. Fluorescein fundus angiography revealed a retinal nonperfusion area only in the left eye, and panretinal photocoagulation was subsequently performed. Our findings show that the reason for the left-right difference in DR was attributed to the more severe choroidal coloboma and retinal thinning in the patient's right eye compared to his left eye, thus reducing oxygen demand, as is also seen in eyes with severe myopia.
Yanagi, Yasuo; Mohla, Aditi; Lee, Shu Yen; Mathur, Ranjana; Chan, Choi Mun; Yeo, Ian; Wong, Tien Yin; Cheung, Chui Ming Gemmy
2018-06-07
Since the advent of optical coherence tomography angiography (OCT-A), nonexudative neovascularization has been described in the fellow eyes of unilateral exudative age-related macular degeneration (AMD). However, there is limited literature describing the natural course and optimal management of these lesions. To determine the incidence of fellow eye involvement in patients presenting with unilateral typical AMD or polypoidal choroidal vasculopathy and to evaluate the patterns of OCT-A changes within 6 months before the onset of exudative changes, especially focusing on nonexudative neovascularization. Data for this study were taken from a prospective, observational cohort study involving Asian patients with exudative AMD in the Asian AMD Phenotyping Study between October 2015 and March 2016. Analyses began in June 2017. Only patients who had gradable OCT-A and indocyanine green angiography (ICGA) scans of the fellow eye at baseline and follow-up at least 6 months apart were included for the analysis. The contralateral eye was evaluated for presence of nonexudative neovascularization based on multimodal imaging, which included ICGA, spectral domain optical coherence tomography, and OCT-A. The difference between the incidence of those with nonexudative choroidal neovascularization and those without as analyzed using log-rank test and qualitative analysis of OCT-A images. We included 95 fellow eyes of 95 patients who presented with unilateral exudative AMD with a mean (SD) age of 68.6 (8.6) years. Nonexudative neovascularization was present in 18 eyes (19%) (8 [22.9%] and 10 [19.0%] fellow eyes with typical AMD and polypoidal choroidal vasculopathy, respectively; 8 [44.4%] on OCT-A; 5 [27.8%] on ICGA; and 5 [27.8%] on both OCT-A and ICGA). Development of exudative changes was noted in 6 fellow eyes (6.3%). Four eyes developed exudation from previously noted nonexudative neovascularization, and 2 eyes arose exudative changes from de novo. The probability of developing exudation within 6 months was significantly higher in eyes with baseline nonexudative neovascularization (0.087; 95% CI, 0.0033-0.210) compared with eyes without (0.010; 95% CI, 0.0026-0.041) (P = .008). In all eyes whose OCT-A images were available immediately before the onset of exudative changes, there was an increase in the size of network vessels compared with baseline. The presence of nonexudative neovascularization may predispose to the development of exudative changes.
Baget-Bernaldiz, Marc; Romero-Aroca, Pedro; Bautista-Perez, Angel; Mercado, Joaquin
2017-10-01
To determine the changes in the multifocal electroretinogram (mfERG) at 1 year in a clinical series of diabetic macular edema (DME) patients treated with ranibizumab (RNBZ) using a pro re nata protocol. We analyzed a clinical series of 35 eyes of 35 patients with DME at baseline and after treating them with RNBZ over 1 year, in order to determine the change in the macular function, which was assessed by means of the response density and the implicit time of the first-order kernel (FOK) P1 wave of the mfERG at the foveola (R1), fovea (R2) and parafovea (R3). These electrophysiological parameters were studied taking into account different independent variables, such as DME type, degree of diabetic retinopathy (DR), level of preservation of both the ellipsoid zone (IS/OS) and the external limiting membrane (ELM) and changes in central retinal thickness (CRT) and total macular volume (TMV). We also studied the relationship between the response density and the best-corrected visual acuity (BCVA). Eyes with cystic and spongiform DME showed better response density with respect to the serous type (p < 0.001) at baseline. Similarly, eyes with high IS/OS and ELM preservation rates showed higher initial response density compared to the others (p < 0.001). Eyes with moderate DR had better response density compared to those with severe and proliferative DR (p = 0.001). At the beginning of the study, those eyes with proliferative and severe DR showed longer implicit times with respect to those with moderate DR (p = 0.04). The response density significantly increased in eyes that anatomically restored the IS/OS and the ELM after being treated with RNBZ (both p < 0.001). Similarly, eyes with spongiform DME further improved the response density with respect to those with cystic and serous DME (p < 0.001). On the contrary, eyes with hard exudates showed less improvement in their response density at the end of the study (p < 0.001). We observed a significant relationship between BCVA and the response density achieved at the end of the study (p = 0.012). Eyes with severe and proliferative DR significantly shortened implicit time compared to those with moderate DR (p = 0.04). The multifocal electroretinogram allowed us to differentiate groups of eyes with DME according to their electrophysiological profile, both initially and after being treated with RNBZ. Ranibizumab increased the response density in all DME types included in the study, with a maximum response in those eyes with spongiform type. Once treated with RNBZ, the macular electrophysiological activity improved in eyes that had a well-preserved ellipsoid zone and ELM. The presence of hard exudates was a limitation to the response density achieved at the foveola.
Hayashi, Ken; Yoshida, Motoaki; Manabe, Shin-ichi; Hayashi, Hideyuki
2010-01-01
To compare all-distance visual acuity and contrast visual acuity with and without glare (glare visual acuity) between phakic eyes with a clear lens and pseudophakic eyes with a monofocal intraocular lens. Hayashi Eye Hospital, Fukuoka, Japan. This study comprised phakic), pseudophakic eyes in 4 age groups (40s, 50s, 60s, 70s). Corrected visual acuity from far to near, contrast visual acuity, and glare visual acuity were examined. The mean corrected intermediate and near visual acuities were significantly better in phakic eyes than in pseudophakic eyes in patients in their 40s and 50s (P
von Marchtaler, Philipp V; Weller, Julia M; Kruse, Friedrich E; Tourtas, Theofilos
2018-01-01
To perform a fellow eye comparison of outcomes and complications when using air or sulfur hexafluoride (SF6) gas as a tamponade in Descemet membrane endothelial keratoplasty (DMEK). One hundred thirty-six eyes of 68 consecutive patients who underwent uneventful DMEK in both eyes for Fuchs endothelial corneal dystrophy were included in this retrospective study. Inclusion criteria were air tamponade (80% of the anterior chamber volume) in the first eye and 20% SF6 gas tamponade (80% of the anterior chamber volume) in the second eye; and same donor tissue culture condition in both eyes. All eyes received laser iridotomy on the day before DMEK. Main outcome measures included preoperative and postoperative best-corrected visual acuity, endothelial cell density, corneal volume, rebubbling rate, and rate of postoperative pupillary block caused by the air/gas bubble. Thirteen of 68 eyes (19.1%) with an air tamponade needed rebubbling compared with 4 of 68 eyes (5.9%) with an SF6 gas tamponade (P = 0.036). Postoperative pupillary block necessitating partial release of air/gas occurred in 1 eye (1.5%) with an air tamponade and 3 eyes (4.4%) with an SF6 gas tamponade (P = 0.301). There were no significant differences in preoperative and postoperative best-corrected visual acuity, endothelial cell density, and corneal volume within 3-month follow-up. Our results confirm the previously reported better graft adhesion when using an SF6 gas tamponade in DMEK without increased endothelial cell toxicity. The rate of pupillary block in eyes with an SF6 gas tamponade was comparable to that with an air tamponade. As a consequence, we recommend using SF6 gas as the tamponade in DMEK.
Yang, Hongli; Thompson, Hilary; Roberts, Michael D.; Sigal, Ian A.; Downs, J. Crawford
2011-01-01
Purpose. To retest the hypothesis that monkey ONH connective tissues become hypercompliant in early experimental glaucoma (EEG), by using 3-D histomorphometric reconstructions, and to expand the characterization of EEG connective tissue deformation to nine EEG eyes. Methods. Trephinated ONH and peripapillary sclera from both eyes of nine monkeys that were perfusion fixed, with one normal eye at IOP 10 mm Hg and the other EEG eye at 10 (n = 3), 30 (n = 3), or 45 (n = 3) mm Hg were serial sectioned, 3-D reconstructed, 3-D delineated, and quantified with 3-D reconstruction techniques developed in prior studies by the authors. Overall, and for each monkey, intereye differences (EEG eye minus normal eye) for each parameter were calculated and compared by ANOVA. Hypercompliance in the EEG 30 and 45 eyes was assessed by ANOVA, and deformations in all nine EEG eyes were separately compared by region without regard for fixation IOP. Results. Hypercompliant deformation was not significant in the overall ANOVA, but was suggested in a subset of EEG 30/45 eyes. EEG eye deformations included posterior laminar deformation, neural canal expansion, lamina cribrosa thickening, and posterior (outward) bowing of the peripapillary sclera. Maximum posterior laminar deformation and scleral canal expansion co-localized to either the inferior nasal or superior temporal quadrants in the eyes with the least deformation and involved both quadrants in the eyes achieving the greatest deformation. Conclusions. The data suggest that, in monkey EEG, ONH connective tissue hypercompliance may occur only in a subset of eyes and that early ONH connective tissue deformation is maximized in the superior temporal and/or inferior nasal quadrants. PMID:20702834
A portable device for measuring donor corneal transparency in eye banks.
Parekh, Mohit; Ferrari, Stefano; Ruzza, Alessandro; Pugliese, Mariarosaria; Ponzin, Diego; Salvalaio, Gianni
2014-03-01
To develop a portable device for measuring the donor corneal transparency and validate its efficacy for corneal evaluation in the eye-banks and for research. The transparency device (TD) has a light source, a detachable system for corneal insertion and a base for light transmission. The probe detects the transmitted light which is measured by a lux-meter. A contact lens was set as 'control' to reduce the light scattering concern, an empty petri-plate as 'blank' and the cornea as 'sample'. Two experts and non-experts (masked) observed the corneas for subjective analysis which was then compared using the TD. The parameters observed were scars, foreign-body, stromal-deformities, folds, thickness and opacity which were then converted to a relative overall percentage by the observer. Twenty corneas were evaluated for correlation, five tissues to obtain standard-deviation and twenty-four pairs for a comparative study. Experts mimicked the eye-banks with long-term experience while non-experts mimicked the emerging eye-banks. Subjective values by the experts closely resembled the measurements by TD. The average correlation between the experts and the non-experts to TD was 0.985 and 0.960 respectively. TD showed higher reproducibility than experts followed by the non-experts. The comparative study showed that increase in thickness reduces the transparency. TD is portable, easy, efficient, maintains sterility and less expensive hence the emerging eye-banks and researchers can use to raise their standards and evaluate the transparency for in vitro tests and comparative studies. The suitable transparency for the cornea deemed for clinical applications was found to be >75 %.
Some characteristics of optokinetic eye-movement patterns : a comparative study.
DOT National Transportation Integrated Search
1970-07-01
Long-associated with transportation ('railroad nystagmus'), optokinetic (OPK) nystagmus is an eye-movement reaction which occurs when a series of moving objects crosses the visual field or when an observer moves past a series of objects. Similar cont...
Effect of Topical Calcium Channel Blockers on Intraocular Pressure in Steroid-induced Glaucoma.
Ganekal, Sunil; Dorairaj, Syril; Jhanji, Vishal; Kudlu, Krishnaprasad
2014-01-01
To evaluate the effect of 0.125% verapamil and 0.5% diltiazem eye drops on intraocular pressure (IOP) in steroid-induced glaucoma in rabbit eyes. A total of 18 rabbits with steroid-induced glaucoma were divided into three groups (A, B and C; n = 6 each). Right eyes in groups A, B and C received 0.5% diltiazem, 0.125% verapamil and 0.5% timolol eye drops twice daily for 12 days, respectively; whereas, left eyes received distilled water. IOP was measured with Tono-pen XL at baseline, day 4, day 8, and day 12 of treatment. Both 0.5% diltiazem and 0.125% verapamil eye drops significantly reduced IOP compared to control eyes (p < 0.05). Reduction of IOP by 0.5% diltiazem, 0.125% verapamil eye drops were comparable to 0.5% timolol. No surface toxicity or systemic side effects were noted during the study period. Calcium channel blockers, verapamil, and diltia-zem significantly reduced IOP in rabbiteyes. This group of drugs may have a potential role in treatment of glaucoma How to cite this article: Ganekal S, Dorairaj S, Jhanji V, Kudlu K. Effect of Topical Calcium Channel Blockers on Intraocular Pressure in Steroid-induced Glaucoma. J Current Glau Prac 2014;8(1):15-19.
Vasundhara, V; Lashkari, Krishna Prasada
2017-01-01
In-vitro study was done to evaluate the incidence of MB2 canals using three different methods (CBCT, CLINICAL ANALYSIS AND DENTAL LOUPES) and to compare the efficacy of the three methods in identifying the incidence of MB2 canals in maxillary permanent first molars. The study sample consisted of 120 extracted intact permanent maxillary molars. These extracted teeth were subjected to CBCT. Later the teeth were access opened with naked eye to find the incidence of MB2 canal, and then the teeth were visualised under dental loupe to locate MB2 canal if they were missed under naked eye. Results was statistically analysed by Mc Nemar's tests with Bonferroni correction, Chi square test and Cochran's Q test. CBCT showed high incidence (68.3%) of MB2 canal in maxillary first molars and it showed to be a reliable method in detecting MB2 canal. When compared to dental loupe (52.5%) and naked eye (25%), the dental loupe improved the detection of MB2 canal. Within the parameter of this study in detecting the incidence of MB2 canal, using CBCT dental loupes and naked eye, detection of MB2 canal was significantly higher with CBCT followed by dental loupe and least with naked eye.
NASA Technical Reports Server (NTRS)
Nam, M. H.; Winters, J. M.; Stark, L.
1981-01-01
Voluntary active head rotations produced vestibulo-ocular reflex eye movements (VOR) with the subject viewing a fixation target. When this target jumped, the size of the refixation saccades were a function of the ongoing initial velocity of the eye. Saccades made against the VOR were larger in magnitude. Simulation of a reciprocally innervated model eye movement provided results comparable to the experimental data. Most of the experimental effect appeared to be due to linear summation for saccades of 5 and 10 degree magnitude. For small saccades of 2.5 degrees, peripheral nonlinear interaction of state variables in the neuromuscular plant also played a role as proven by comparable behavior in the simulated model with known controller signals.
Roberts, Philipp K; Goldstein, Debra A; Fawzi, Amani A
2017-08-01
Purpose/Aim of the study: To assess the ability of optical coherence tomographic angiography (OCTA) to visualize the normal iris vasculature as well as neovascularization of the iris (NVI). Study participants with healthy eyes, patients at risk of NVI development and patients with active or regressed NVI were consecutively included in this cross-sectional observational study. Imaging was performed using a commercially available OCTA system (RTVue- XR Avanti, Optovue Inc., Fremont, CA, USA). Abnormal iris vessels were graded on OCTA according to a modified clinical staging system and compared to slitlamp and gonioscopic findings. Fifty eyes of 26 study participants (16 healthy eyes, 19 eyes at risk, 15 eyes with different stages of NVI) were imaged using OCTA. In 11 out of 16 healthy eyes (69%) with light or moderately dark iris pigmentation, we observed physiological, radially aligned iris vasculature on OCTA imaging, which could not be visualized in five eyes (31%) with darkly pigmented irides. One eye in the "eyes at risk" group was diagnosed with NVI based on OCTA, which was not observed clinically. Fifteen eyes with clinically active or regressed NVI were imaged. Different stages of NVI could be differentiated by OCTA, corresponding well to an established clinical grading system. Four eyes showed regressed NVI by OCTA, not seen clinically, and were graded as a newly defined stage 4. This pilot clinical study showed that OCTA for imaging of the iris vasculature in health and disease is highly dependent on iris pigmentation. Fine, clinically invisible iris vessels can be visualized by OCTA in the very early stages as well as in the regressed stage of NVI.
Roberts, Philipp K.; Goldstein, Debra A.; Fawzi, Amani A.
2017-01-01
Purpose/Aim of the study To assess the ability of optical coherence tomographic angiography (OCTA) to visualize the normal iris vasculature as well as neovascularization of the iris (NVI). Materials and Methods Study participants with healthy eyes, patients at risk of NVI development and patients with active or regressed NVI were consecutively included in this cross-sectional observational study. Imaging was performed using a commercially available OCTA system (RTVue- XR Avanti, Optovue Inc., Fremont, CA, USA). Abnormal iris vessels were graded on OCTA according to a modified clinical staging system and compared to slitlamp and gonioscopic findings. Results Fifty eyes of 26 study participants (16 healthy eyes, 19 eyes at risk, 15 eyes with different stages of NVI) were imaged using OCTA. In 11 out of 16 healthy eyes (69%) with light or moderately dark iris pigmentation, we observed physiological, radially aligned iris vasculature on OCTA imaging, which could not be visualized in five eyes (31%) with darkly pigmented irides. One eye in the “eyes at risk” group was diagnosed with NVI based on OCTA, which was not observed clinically. Fifteen eyes with clinically active or regressed NVI were imaged. Different stages of NVI could be differentiated by OCTA, corresponding well to an established clinical grading system. Four eyes showed regressed NVI by OCTA, not seen clinically, and were graded as a newly defined stage 4. Conclusions This pilot clinical study showed that OCTA for imaging of the iris vasculature in health and disease is highly dependent on iris pigmentation. Fine, clinically invisible iris vessels can be visualized by OCTA in the very early stages as well as in the regressed stage of NVI. PMID:28441067
Dees, D Dustin; Spahn, Kate J; Wagner, Lynsey Smith; Greller, Andrew; Paglia, Danielle; Armour, Micki D; Madsen, Richard
2017-11-01
To determine whether topical hypotensive medications prevent postoperative ocular hypertension (POH) after phacoemulsification. 52 client-owned dogs (88 eyes). Diabetic and nondiabetic dogs having undergone phacoemulsification were included in this retrospective study. The control group received no ocular hypotensive medications. The treatment groups received latanoprost, dorzolamide, or dorzolamide/timolol, beginning immediately after surgery, for 2-week duration. IOPs were obtained at initial examination followed by 4 h, 24 h, 7 days, and 14 days postoperatively. POH was defined as an IOP above 20 mmHg (POH20) or 25 mmHg (POH25). POH20 occurred in 33 of 87 eyes (37.93%), including 11 of 21 eyes (52.38%) in the control group, three of 23 eyes (13.04%) in the latanoprost group, eight of 15 eyes (53.33%) in the dorzolamide group, and 11 of 28 eyes (39.29%) in the dorzolamide/timolol group. Active treatment groups were compared to the control group, and the overall group effect was not significant (P = 0.11). POH25 occurred in 22 of 86 eyes (25.58%), including seven of 21 eyes (33.33%) in the control group, two of 23 eyes (8.70%) in the latanoprost group, five of 15 eyes (33.33%) in the dorzolamide group, and eight of 27 eyes (29.63%) in the dorzolamide/timolol group. Active treatment groups were compared to the control group, and the overall group effect was not significant (P = 0.31). Intraoperative use of intracameral tissue plasminogen activator significantly decreased the chances of POH25 (P = 0.0063). The latanoprost group had a substantially lower percentage of POH 20 and POH25 compared to the control and other active treatment groups, although statistical significance was not achieved. Intraoperative intracameral tissue plasminogen activator decreased the incidence of POH25. © 2017 American College of Veterinary Ophthalmologists.
Changes in macular pigment optical density after membrane peeling.
Romano, Mario R; Cennamo, Gilda; Grassi, Piergiacomo; Sparnelli, Federica; Allegrini, Davide; Cennamo, Giovanni
2018-01-01
To highlight the differences in macular pigment optical density (MPOD) between eyes with vitreoretinal interface syndrome and healthy control eyes, to assess the changes in MPOD in eyes treated with macular peeling, to investigate the relationships between MPOD changes and measures of retinal sensitivity such as best corrected visual acuity (BCVA) and microperimetry. In this cross-sectional comparative study, 30 eyes affected by idiopathic epiretinal membrane (iERM, 15eyes) or full-thickness macular hole (FTMH, 15eyes) were compared with 60 eyes from 30 healthy age-matched patients. MPOD values (mean MPOD, maximum MPOD, MPOD area, and MPOD volume) were measured in a range of 4°-7° of eccentricity around the fovea, using the one-wavelength reflectometry method (Visucam 200, Carl-Zeiss Meditec). Patients affected by iERM and FTMH were treated with vitrectomy and epiretinal membrane-inner limiting membrane (ERM-ILM) peeling, with follow-up examinations performed preoperatively and 6 months postoperatively. The main outcome measures were the differences in MPOD between eyes with vitreoretinal interface syndrome and healthy eyes, changes in MPOD after ERM-ILM peeling, and relationships between MPOD and functional changes. Mean MPOD differed significantly between control eyes and those with iERM (P = .0001) or FTMH (P = .0006). The max MPOD and MPOD area increased, but not significantly. After peeling, the only significant change in MPOD was in MPOD volume (P = .01). In the ERM group, postoperative mean MPOD correlated significantly with best-corrected visual acuity (r = .739, P = .002). MPOD was reduced in patients with iERM or FTMH compared with healthy eyes. We found a significant correlation between the mean postoperative MPOD and postoperative BCVA, hypothesizing that the postoperative increase in mean MPOD could be due to a change in distribution for unfolding and expansion of the fovea after the peeling. MOPD may be considered as a prognostic factor associated with a good visual prognosis in patients with iERM.
Comparative effect of lens care solutions on blink rate, ocular discomfort and visual performance.
Yang, Shun-nan; Tai, Yu-chi; Sheedy, James E; Kinoshita, Beth; Lampa, Matthew; Kern, Jami R
2012-09-01
To help maintain clear vision and ocular surface health, eye blinks occur to distribute natural tears over the ocular surface, especially the corneal surface. Contact lens wearers may suffer from poor vision and dry eye symptoms due to difficulty in lens surface wetting and reduced tear production. Sustained viewing of a computer screen reduces eye blinks and exacerbates such difficulties. The present study evaluated the wetting effect of lens care solutions (LCSs) on blink rate, dry eye symptoms, and vision performance. Sixty-five adult habitual soft contact lens wearers were recruited to adapt to different LCSs (Opti-free, ReNu, and ClearCare) in a cross-over design. Blink rate in pictorial viewing and reading (measured with an eyetracker), dry eye symptoms (measured with the Ocular Surface Disease Index questionnaire), and visual discrimination (identifying tumbling E) immediately before and after eye blinks were measured after 2 weeks of adaption to LCS. Repeated measures anova and mixed model ancova were conducted to evaluate effects of LCS on blink rate, symptom score, and discrimination accuracy. Opti-Free resulted in lower dry eye symptoms (p = 0.018) than ClearCare, and lower spontaneous blink rate (measured in picture viewing) than ClearCare (p = 0.014) and ReNu (p = 0.041). In reading, blink rate was higher for ClearCare compared to ReNu (p = 0.026) and control (p = 0.024). Visual discrimination time was longer for the control (daily disposable lens) than for Opti-Free (p = 0.007), ReNu (p = 0.009), and ClearCare (0.013) immediately before the blink. LCSs differently affected blink rate, subjective dry eye symptoms, and visual discrimination speed. Those with wetting agents led to significantly fewer eye blinks while affording better ocular comfort for contact lens wearers, compared to that without. LCSs with wetting agents also resulted in better visual performance compared to wearing daily disposable contact lenses. These presumably are because of improved tear film quality. © 2012 The College of Optometrists.
Hu, Rongrong; Wang, Chenkun; Gu, Yangshun; Racette, Lyne
2016-01-01
Abstract Detection of progression is paramount to the clinical management of glaucoma. Our goal is to compare the performance of standard automated perimetry (SAP), short-wavelength automated perimetry (SWAP), and frequency-doubling technology (FDT) perimetry in monitoring glaucoma progression. Longitudinal data of paired SAP, SWAP, and FDT from 113 eyes with primary open-angle glaucoma enrolled in the Diagnostic Innovations in Glaucoma Study or the African Descent and Glaucoma Evaluation Study were included. Data from all tests were expressed in comparable units by converting the sensitivity from decibels to unitless contrast sensitivity and by expressing sensitivity values in percent of mean normal based on an independent dataset of 207 healthy eyes with aging deterioration taken into consideration. Pointwise linear regression analysis was performed and 3 criteria (conservative, moderate, and liberal) were used to define progression and improvement. Global mean sensitivity (MS) was fitted with linear mixed models. No statistically significant difference in the proportion of progressing and improving eyes was observed across tests using the conservative criterion. Fewer eyes showed improvement on SAP compared to SWAP and FDT using the moderate criterion; and FDT detected less progressing eyes than SAP and SWAP using the liberal criterion. The agreement between these test types was poor. The linear mixed model showed a progressing trend of global MS overtime for SAP and SWAP, but not for FDT. The baseline estimate of SWAP MS was significantly lower than SAP MS by 21.59% of mean normal. FDT showed comparable estimation of baseline MS with SAP. SWAP and FDT do not appear to have significant benefits over SAP in monitoring glaucoma progression. SAP, SWAP, and FDT may, however, detect progression in different glaucoma eyes. PMID:26886602
Marcus, Inna; Tung, Irene T; Dosunmu, Eniolami O; Thiamthat, Warakorn; Freedman, Sharon F
2013-12-01
To compare anterior segment findings identified in young children using digital photographic images from the Lytro light field camera to those observed clinically. This was a prospective study of children <9 years of age with an anterior segment abnormality. Clinically observed anterior segment examination findings for each child were recorded and several digital images of the anterior segment of each eye captured with the Lytro camera. The images were later reviewed by a masked examiner. Sensitivity of abnormal examination findings on Lytro imaging was calculated and compared to the clinical examination as the gold standard. A total of 157 eyes of 80 children (mean age, 4.4 years; range, 0.1-8.9) were included. Clinical examination revealed 206 anterior segment abnormalities altogether: lids/lashes (n = 21 eyes), conjunctiva/sclera (n = 28 eyes), cornea (n = 71 eyes), anterior chamber (n = 14 eyes), iris (n = 43 eyes), and lens (n = 29 eyes). Review of Lytro photographs of eyes with clinically diagnosed anterior segment abnormality correctly identified 133 of 206 (65%) of all abnormalities. Additionally, 185 abnormalities in 50 children were documented at examination under anesthesia. The Lytro camera was able to document most abnormal anterior segment findings in un-sedated young children. Its unique ability to allow focus change after image capture is a significant improvement on prior technology. Copyright © 2013 American Association for Pediatric Ophthalmology and Strabismus. Published by Mosby, Inc. All rights reserved.
Computer vision syndrome and ergonomic practices among undergraduate university students.
Mowatt, Lizette; Gordon, Carron; Santosh, Arvind Babu Rajendra; Jones, Thaon
2018-01-01
To determine the prevalence of computer vision syndrome (CVS) and ergonomic practices among students in the Faculty of Medical Sciences at The University of the West Indies (UWI), Jamaica. A cross-sectional study was done with a self-administered questionnaire. Four hundred and nine students participated; 78% were females. The mean age was 21.6 years. Neck pain (75.1%), eye strain (67%), shoulder pain (65.5%) and eye burn (61.9%) were the most common CVS symptoms. Dry eyes (26.2%), double vision (28.9%) and blurred vision (51.6%) were the least commonly experienced symptoms. Eye burning (P = .001), eye strain (P = .041) and neck pain (P = .023) were significantly related to level of viewing. Moderate eye burning (55.1%) and double vision (56%) occurred in those who used handheld devices (P = .001 and .007, respectively). Moderate blurred vision was reported in 52% who looked down at the device compared with 14.8% who held it at an angle. Severe eye strain occurred in 63% of those who looked down at a device compared with 21% who kept the device at eye level. Shoulder pain was not related to pattern of use. Ocular symptoms and neck pain were less likely if the device was held just below eye level. There is a high prevalence of Symptoms of CVS amongst university students which could be reduced, in particular neck pain and eye strain and burning, with improved ergonomic practices. © 2017 John Wiley & Sons Ltd.
Borghol-Kassar, R; Menezo-Rozalén, J L; Harto-Castaño, M A; Desco-Esteban, M C
2015-03-01
The aim of this article is to study the effect of unilateral congenital cataract surgery on ocular growth and corneal flattening. This is a cross-sectional study of 59 patients operated on due to a unilateral congenital cataract. The median age of the patients at the time of diagnosis was 17 months (interquartile range, 5-39 months). The median age at cataract the time of surgery was 28 months (interquartile range, 8-52 months), and the mean follow-up between cataract surgery and assessments was 149.7±69.9 months (range, 30-319 months). Axial length and corneal curvature were measured in both operated and non-operated eyes, comparing the results between them. There were no statistically significant differences for axial length growth or corneal flattening between operated and non-operated eyes: axial length (P=.327, Student t test) and corneal curvature (P=.078, Student t test). A sub-analysis was performed using the visual acuity and the age of the patient at the time of surgery. The only statistically significant data (P=.007, Student t test) was a lower axial length in operated eyes compared to non-operated eyes, in the non-deep-amblyopia group. No significant axial length growth modifications were observed between operated and non-operated eyes. Only the non-deep-amblyopia group presented with a lower axial length in the operated eyes compared to non-operated eyes. No significant differences in corneal flattening were found between groups after unilateral congenital cataract surgery. Copyright © 2011 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.
Impact of Glaucoma and Dry Eye on Text-Based Searching
Sun, Michelle J.; Rubin, Gary S.; Akpek, Esen K.; Ramulu, Pradeep Y.
2017-01-01
Purpose We determine if visual field loss from glaucoma and/or measures of dry eye severity are associated with difficulty searching, as judged by slower search times on a text-based search task. Methods Glaucoma patients with bilateral visual field (VF) loss, patients with clinically significant dry eye, and normally-sighted controls were enrolled from the Wilmer Eye Institute clinics. Subjects searched three Yellow Pages excerpts for a specific phone number, and search time was recorded. Results A total of 50 glaucoma subjects, 40 dry eye subjects, and 45 controls completed study procedures. On average, glaucoma patients exhibited 57% longer search times compared to controls (95% confidence interval [CI], 26%–96%, P < 0.001), and longer search times were noted among subjects with greater VF loss (P < 0.001), worse contrast sensitivity (P < 0.001), and worse visual acuity (P = 0.026). Dry eye subjects demonstrated similar search times compared to controls, though worse Ocular Surface Disease Index (OSDI) vision-related subscores were associated with longer search times (P < 0.01). Search times showed no association with OSDI symptom subscores (P = 0.20) or objective measures of dry eye (P > 0.08 for Schirmer's testing without anesthesia, corneal fluorescein staining, and tear film breakup time). Conclusions Text-based visual search is slower for glaucoma patients with greater levels of VF loss and dry eye patients with greater self-reported visual difficulty, and these difficulties may contribute to decreased quality of life in these groups. Translational Relevance Visual search is impaired in glaucoma and dry eye groups compared to controls, highlighting the need for compensatory strategies and tools to assist individuals in overcoming their deficiencies. PMID:28670502
Habay, T; Majzoub, S; Perrault, O; Rousseau, C; Pisella, P J
2014-03-01
To assess the functional impact of the severity of dry eye on the quality of vision by measuring an Objective Scatter Index (OSI) using double pass aberrometry. Twenty-eight patients (56 eyes) with dry eye syndromes of varying severity participated in this study. A double-pass aberrometer was used to measure the dynamic changes in the OSI for 20 seconds. The mean and standard deviations of the OSI and the number of blinks occurring during the examination were compared as a function of the clinical severity of dry eye disease. The mean OSI increased with the severity of dry eye syndrome with a significant difference for stages 3 (P<0.01) and 4 (P<0.001) compared to stages 1 and 2, without a significant difference based on age (P>0.8) or visual acuity (P>0.2). Standard deviation of the OSI also increased with the severity of dry eye disease, with a significant difference for stages 3 (P<0.01) and 4 (P<0.0001) compared to stages 1 and 2, with no significant increase in the number of blinks (P>0.2). The values of the OSI standard deviation represented the dynamic nature of aberrometric changes related to the instability of the tear film. Quality of vision of patients deteriorated in relation to the severity of their dry eye. The analysis of OSI standard deviation appears to be an objective way to assess the intensity of subjective visual disturbances reported by patients with dry eye syndrome. It also provides a new tool to assess the severity of damage to the ocular surface. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
Pavlovic, Ivana; Shajari, Mehdi; Herrmann, Eva; Schmack, Ingo; Lencova, Anna; Kohnen, Thomas
2017-12-01
This meta-analysis compares Descemet membrane endothelial keratoplasty (DMEK) with Descemet stripping automated endothelial keratoplasty (DSAEK) to evaluate their strength and weakness profiles. Meta-analysis. We performed a meta-analysis and searched the peer-reviewed literature in PubMed, Cochrane Library, Web of Science, and Embase following Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Prospective and retrospective trials performing and comparing DMEK and DSAEK were included. Effects were calculated as odds ratios or standardized mean differences. A total of 11 studies with a total of 723 eyes (350 DMEK and 373 DSAEK) were included. No significant difference was found regarding the total detachment rate, graft failure, and rejection. One of 340 eyes undergoing DMEK showed total detachment and 5 of 363 eyes undergoing DSAEK showed total detachment (P = 0.28). Six of 280 eyes undergoing DMEK showed graft failure; 1 of 313 eyes undergoing DSAEK developed this complication (P = 0.18). No rejection was observed in 158 eyes undergoing DMEK; 4 cases of rejection occurred in 196 eyes undergoing DSAEK (P = 0.37). No significant difference was found regarding endothelial cell loss (P = 0.48). There was a significantly higher partial detachment rate with DMEK: 88 of 340 eyes undergoing DMEK showed partial detachment; 16 of 363 eyes undergoing DSAEK showed this complication (P < 0.00001). DMEK was superior in best-corrected visual acuity after 6 months (P < 0.001), subjective evaluation of visual acuity (P = 0.001), patient satisfaction (P < 0.001), and was the method preferred by patients (P = 0.001). DMEK and DSAEK have a similar complication profile. However, the superiority in the visual outcome and patient satisfaction makes DMEK the preferred option for most patients.
Kymionis, George D; Liakopoulos, Dimitrios A; Grentzelos, Michael A; Tsoulnaras, Konstantinos I; Detorakis, Efstathios T; Cochener, Béatrice; Tsilimbaris, Miltiadis K
2015-08-01
To evaluate the effect of a regenerative agent (RGTA) [Cacicol20-poly(carboxymethyl glucose sulfate); OTR3, Paris, France] on corneal reepithelialization and pain after corneal cross-linking (CXL) for keratoconus. In this prospective comparative (contralateral) clinical study, patients with bilateral progressive keratoconus underwent CXL treatment. The corneal epithelium during CXL was removed using transepithelial phototherapeutic keratectomy (Cretan protocol). One eye of each patient was randomly instilled with an RGTA (Cacicol20) once a day (study group), whereas the fellow eye was instilled with artificial tears (control group). Patients were examined daily until complete reepithelialization. Postoperative examinations included slit-lamp biomicroscopy to assess the epithelial defect size and subjective evaluation of pain. The study enrolled 18 patients (36 eyes). The mean epithelial defect size for study and control groups was 19.6 ± 4.2 mm versus 21.5 ± 2.8 mm, respectively, at day 1 (P = 0.019) and 6.4 ± 3.4 mm versus 7.9 ± 4.3 mm, respectively, at day 2 (P = 0.014). At day 3 postoperatively, 61.1% of study eyes were fully reepithelialized, compared with 11.1% of control eyes (P = 0.002). RGTA (Cacicol20) instillation seems to result in faster corneal reepithelialization after CXL in this study. However, there was no significant effect in subjective pain/discomfort.
The effects of PEP-1-FK506BP on dry eye disease in a rat model.
Kim, Dae Won; Lee, Sung Ho; Ku, Sae Kwang; Lee, Ji Eun; Cha, Hyun Ju; Youn, Jong Kyu; Kwon, Hyeok Yil; Park, Jong Hoon; Park, Eun Young; Cho, Sung-Woo; Han, Kyu Hyung; Park, Jinseu; Eum, Won Sik; Choi, Soo Young
2015-03-01
As FK506 binding proteins (FK506BPs) are known to play an important role in the regulation of a variety of biological processes related to cell survival, this study was designed to examined the protective effects of FK506 binding protein 12 (FK506BP) on low humidity air flow induced dry eye in a rat model using transduced PEP-1-FK506BP. After the topical application of PEP-1-FK506BP, tear volumes were markedly increased and significant prevention of cornea damage was observed compared with dry eye rats. Further, immunohistochemical analysis demonstrated that PEP-1-FK506BP markedly prevented damage to the cornea, the bulbar conjunctiva, and the palpebral conjunctiva epithelial lining compared with dry eye rats. In addition, caspase-3 and PARP expression levels were found to be decreased. These results demonstrated that topical application of PEP-1-FK506BP significantly ameliorates dry eye injury in an animal model. Thus, we suggest that PEP-1-FK506BP can be developed as a new ophthalmic drop to treat dry eye diseases.
Tutorial on Biostatistics: Linear Regression Analysis of Continuous Correlated Eye Data
Ying, Gui-shuang; Maguire, Maureen G; Glynn, Robert; Rosner, Bernard
2017-01-01
Purpose To describe and demonstrate appropriate linear regression methods for analyzing correlated continuous eye data. Methods We describe several approaches to regression analysis involving both eyes, including mixed effects and marginal models under various covariance structures to account for inter-eye correlation. We demonstrate, with SAS statistical software, applications in a study comparing baseline refractive error between one eye with choroidal neovascularization (CNV) and the unaffected fellow eye, and in a study determining factors associated with visual field data in the elderly. Results When refractive error from both eyes were analyzed with standard linear regression without accounting for inter-eye correlation (adjusting for demographic and ocular covariates), the difference between eyes with CNV and fellow eyes was 0.15 diopters (D; 95% confidence interval, CI −0.03 to 0.32D, P=0.10). Using a mixed effects model or a marginal model, the estimated difference was the same but with narrower 95% CI (0.01 to 0.28D, P=0.03). Standard regression for visual field data from both eyes provided biased estimates of standard error (generally underestimated) and smaller P-values, while analysis of the worse eye provided larger P-values than mixed effects models and marginal models. Conclusion In research involving both eyes, ignoring inter-eye correlation can lead to invalid inferences. Analysis using only right or left eyes is valid, but decreases power. Worse-eye analysis can provide less power and biased estimates of effect. Mixed effects or marginal models using the eye as the unit of analysis should be used to appropriately account for inter-eye correlation and maximize power and precision. PMID:28102741
Penetrating eye injury in war.
Biehl, J W; Valdez, J; Hemady, R K; Steidl, S M; Bourke, D L
1999-11-01
The percentage of penetrating eye injuries in war has increased significantly in this century compared with the total number of combat injuries. With the increasing use of fragmentation weapons and possibly laser weapons on the battle-field in the future, the rate of eye injuries may exceed the 13% of the total military injuries found in Operations Desert Storm/Shield. During the Iran-Iraq War (1980-1988), eye injuries revealed that retained foreign bodies and posterior segment injuries have an improved prognosis in future military ophthalmic surgery as a result of modern diagnostic and treatment modalities. Compared with the increasing penetrating eye injuries on the battlefield, advances in ophthalmic surgery are insignificant. Eye armor, such as visors that flip up and down and protect the eyes from laser injury, needs to be developed. Similar eye protection is being developed in civilian sportswear. Penetrating eye injury in the civilian sector is becoming much closer to the military model and is now comparable for several reasons.
The effect of emotionally valenced eye region images on visuocortical processing of surprised faces.
Li, Shuaixia; Li, Ping; Wang, Wei; Zhu, Xiangru; Luo, Wenbo
2018-05-01
In this study, we presented pictorial representations of happy, neutral, and fearful expressions projected in the eye regions to determine whether the eye region alone is sufficient to produce a context effect. Participants were asked to judge the valence of surprised faces that had been preceded by a picture of an eye region. Behavioral results showed that affective ratings of surprised faces were context dependent. Prime-related ERPs with presentation of happy eyes elicited a larger P1 than those for neutral and fearful eyes, likely due to the recognition advantage provided by a happy expression. Target-related ERPs showed that surprised faces in the context of fearful and happy eyes elicited dramatically larger C1 than those in the neutral context, which reflected the modulation by predictions during the earliest stages of face processing. There were larger N170 with neutral and fearful eye contexts compared to the happy context, suggesting faces were being integrated with contextual threat information. The P3 component exhibited enhanced brain activity in response to faces preceded by happy and fearful eyes compared with neutral eyes, indicating motivated attention processing may be involved at this stage. Altogether, these results indicate for the first time that the influence of isolated eye regions on the perception of surprised faces involves preferential processing at the early stages and elaborate processing at the late stages. Moreover, higher cognitive processes such as predictions and attention can modulate face processing from the earliest stages in a top-down manner. © 2017 Society for Psychophysiological Research.
NASA Astrophysics Data System (ADS)
Grigoryan, E.; Dadheva, O.; Polinskaya, V.; Guryeva, T.
The avian embryonic eye is used as a model system for studies on the environmental effects on central nervous system development. Here we present results of qualitative investigation of the eye development in quail embryos incubated in micro-"g" environment. In this study we used eyes of Japanese quail (Coturnix coturnix Japonica) embryos "flown" onboard biosatellite Kosmos-1129 and on Mir station within the framework of Mir-NASA Program. Eyes obtained from embryos ranging in age from 3-12 days (E3-E12) were prepared histologically and compared with those of the synchronous and laboratory gound controls. Ther most careful consideration was given to finding and analysis of eye developmental abnormalities. Then they were compared with those already described by experimental teratology for birds and mammals. At the stage of the "eye cup" (E3) we found the case of invalid formation of the inner retina. The latter was represented by disorganized neuroblasts occupying whole posterior chamber of the eye. On the 7th day of quail eye development, at the period of cellular growth activation some cases of small eyes with many folds of overgrowing neural and pigmented retinal layers were detected. In retinal folds of these eyes the normal layering was disturbed as well as the formation of aqueous body and pecten oculi. At this time point the changes were also found in the anterior part of the eye. The peculiarities came out of the bigger width of the cornea and separation of its layers, but were found in synchronous control as well. Few embryos of E10 had also eyes with the abnormities described for E7 but this time they were more vivid because of the completion of eye tissue differentiation. At the stage E12 we found the case evaluated as microphthalmia attending by overgrowth of anterior pigmented tissues - iris and ciliary body attached with the cornea. Most, but not all, of abnormalities we found in eye morphogeneses belonged to the birds "flown" aboard Kosmos- 1129 and were likely induced by specific conditions of that flight. All sorts of disturbances we observed in eye development were similar with dom inated types found in birds and mammals on ground and could be induced by factors we intend to discuss in our report.
Different lasers and techniques for proliferative diabetic retinopathy.
Moutray, Tanya; Evans, Jennifer R; Lois, Noemi; Armstrong, David J; Peto, Tunde; Azuara-Blanco, Augusto
2018-03-15
Diabetic retinopathy (DR) is a chronic progressive disease of the retinal microvasculature associated with prolonged hyperglycaemia. Proliferative DR (PDR) is a sight-threatening complication of DR and is characterised by the development of abnormal new vessels in the retina, optic nerve head or anterior segment of the eye. Argon laser photocoagulation has been the gold standard for the treatment of PDR for many years, using regimens evaluated by the Early Treatment of Diabetic Retinopathy Study (ETDRS). Over the years, there have been modifications of the technique and introduction of new laser technologies. To assess the effects of different types of laser, other than argon laser, and different laser protocols, other than those established by the ETDRS, for the treatment of PDR. We compared different wavelengths; power and pulse duration; pattern, number and location of burns versus standard argon laser undertaken as specified by the ETDRS. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (which contains the Cochrane Eyes and Vision Trials Register) (2017, Issue 5); Ovid MEDLINE; Ovid Embase; LILACS; the ISRCTN registry; ClinicalTrials.gov and the ICTRP. The date of the search was 8 June 2017. We included randomised controlled trials (RCTs) of pan-retinal photocoagulation (PRP) using standard argon laser for treatment of PDR compared with any other laser modality. We excluded studies of lasers that are not in common use, such as the xenon arc, ruby or Krypton laser. We followed Cochrane guidelines and graded the certainty of evidence using the GRADE approach. We identified 11 studies from Europe (6), the USA (2), the Middle East (1) and Asia (2). Five studies compared different types of laser to argon: Nd:YAG (2 studies) or diode (3 studies). Other studies compared modifications to the standard argon laser PRP technique. The studies were poorly reported and we judged all to be at high risk of bias in at least one domain. The sample size varied from 20 to 270 eyes but the majority included 50 participants or fewer.Nd:YAG versus argon laser (2 studies): very low-certainty evidence on vision loss, vision gain, progression and regression of PDR, pain during laser treatment and adverse effects.Diode versus argon laser (3 studies): very-low certainty evidence on vision loss, vision gain, progression and regression of PDR and adverse effects; moderate-certainty evidence that diode laser was more painful (risk ratio (RR) troublesome pain during laser treatment (RR 3.12, 95% CI 2.16 to 4.51; eyes = 202; studies = 3; I 2 = 0%).0.5 second versus 0.1 second exposure (1 study): low-certainty evidence of lower chance of vision loss with 0.5 second compared with 0.1 second exposure but estimates were imprecise and compatible with no difference or an increased chance of vision loss (RR 0.42, 95% CI 0.08 to 2.04, 44 eyes, 1 RCT); low-certainty evidence that people treated with 0.5 second exposure were more likely to gain vision (RR 2.22, 95% CI 0.68 to 7.28, 44 eyes, 1 RCT) but again the estimates were imprecise . People given 0.5 second exposure were more likely to have regression of PDR compared with 0.1 second laser PRP again with imprecise estimate (RR 1.17, 95% CI 0.92 to 1.48, 32 eyes, 1 RCT). There was very low-certainty evidence on progression of PDR and adverse effects.'Light intensity' PRP versus classic PRP (1 study): vision loss or gain was not reported but the mean difference in logMAR acuity at 1 year was -0.09 logMAR (95% CI -0.22 to 0.04, 65 eyes, 1 RCT); and low-certainty evidence that fewer patients had pain during light PRP compared with classic PRP with an imprecise estimate compatible with increased or decreased pain (RR 0.23, 95% CI 0.03 to 1.93, 65 eyes, 1 RCT).'Mild scatter' (laser pattern limited to 400 to 600 laser burns in one sitting) PRP versus standard 'full' scatter PRP (1 study): very low-certainty evidence on vision and visual field loss. No information on adverse effects.'Central' (a more central PRP in addition to mid-peripheral PRP) versus 'peripheral' standard PRP (1 study): low-certainty evidence that people treated with central PRP were more likely to lose 15 or more letters of BCVA compared with peripheral laser PRP (RR 3.00, 95% CI 0.67 to 13.46, 50 eyes, 1 RCT); and less likely to gain 15 or more letters (RR 0.25, 95% CI 0.03 to 2.08) with imprecise estimates compatible with increased or decreased risk.'Centre sparing' PRP (argon laser distribution limited to 3 disc diameters from the upper temporal and lower margin of the fovea) versus standard 'full scatter' PRP (1 study): low-certainty evidence that people treated with 'centre sparing' PRP were less likely to lose 15 or more ETDRS letters of BCVA compared with 'full scatter' PRP (RR 0.67, 95% CI 0.30 to 1.50, 53 eyes). Low-certainty evidence of similar risk of regression of PDR between groups (RR 0.96, 95% CI 0.73 to 1.27, 53 eyes). Adverse events were not reported.'Extended targeted' PRP (to include the equator and any capillary non-perfusion areas between the vascular arcades) versus standard PRP (1 study): low-certainty evidence that people in the extended group had similar or slightly reduced chance of loss of 15 or more letters of BCVA compared with the standard PRP group (RR 0.94, 95% CI 0.70 to 1.28, 270 eyes). Low-certainty evidence that people in the extended group had a similar or slightly increased chance of regression of PDR compared with the standard PRP group (RR 1.11, 95% CI 0.95 to 1.31, 270 eyes). Very low-certainty information on adverse effects. Modern laser techniques and modalities have been developed to treat PDR. However there is limited evidence available with respect to the efficacy and safety of alternative laser systems or strategies compared with the standard argon laser as described in ETDRS.
Variant myopia: A new presentation?
Hussaindeen, Jameel Rizwana; Anand, Mithra; Sivaraman, Viswanathan; Ramani, Krishna Kumar; Allen, Peter M
2018-01-01
Purpose: Variant myopia (VM) presents as a discrepancy of >1 diopter (D) between subjective and objective refraction, without the presence of any accommodative dysfunction. The purpose of this study is to create a clinical profile of VM. Methods: Fourteen eyes of 12 VM patients who had a discrepancy of >1D between retinoscopy and subjective acceptance under both cycloplegic and noncycloplegic conditions were included in the study. Fourteen eyes of 14 age- and refractive error-matched participants served as controls. Potential participants underwent a comprehensive orthoptic examination followed by retinoscopy (Ret), closed-field autorefractor (CA), subjective acceptance (SA), choroidal and retinal thickness, ocular biometry, and higher order spherical aberrations measurements. Results: In the VM eyes, a statistically and clinically significant difference was noted between the Ret and CA and Ret and SA under both cycloplegic and noncycloplegic conditions (multivariate repeated measures analysis of variance, P < 0.0001). A statistically significant difference was observed between the VM eyes, non-VM eyes, and controls for choroidal thickness in all the quadrants (Univariate ANOVA P < 0.05). The VM eyes had thinner choroids (197.21 ± 13.04 μ) compared to the non-VM eyes (249.25 ± 53.70 μ) and refractive error-matched controls (264.62 ± 12.53 μ). No statistically significant differences between groups in root mean square of total higher order aberrations and spherical aberration were observed. Conclusion: Accommodative etiology does not play a role in the refractive discrepancy seen in individuals with the variant myopic presentation. These individuals have thinner choroids in the eye with variant myopic presentation compared to the fellow eyes and controls. Hypotheses and clinical implications of variant myopia are discussed. PMID:29785987
Udani, Jayshree; Vaghela, D B; Rajagopala, Manjusha; Matalia, P D
2012-01-01
Simple allergic conjunctivitis is the most common form of ocular allergy (prevalence 5 - 22 %). It is a hypersensitivity reaction to specific airborne antigens. The disease Vataja Abhishyanda, which is due to vitiation of Vata Pradhana Tridosha is comparable with this condition. The management of simple allergic conjunctivitis in modern ophthalmology is very expensive and it should be followed lifelong and Ayurveda can provide better relief in such manifestation. This is the first research study on Vataja Abhishyanda. Patients were selected from the Outpatient Department (OPD), Inpatient Department (IPD), of the Shalakya Tantra Department and were randomly divided into two groups. In Group-A Bilvadi Ashchyotana and in Group-B Bilvadi eye drops were instilled for three months. Total 32 patients were registered and 27 patients completed the course of treatment. Bilvadi Ashchyotana gave better results in Toda, Sangharsha, Parushya, Kandu and Ragata as compared with Bilvadi Eye Drops in Vataja Abhishyanda.
Barteselli, G; Gomez, M L; Doede, A L; Chhablani, J; Gutstein, W; Bartsch, D-U; Dustin, L; Azen, S P; Freeman, W R
2014-10-01
To evaluate visual function variations in eyes with age-related macular degeneration (AMD) compared to normal eyes under different light/contrast conditions using a time-dependent visual acuity testing instrument, the Central Vision Analyzer (CVA). Overall, 37 AMD eyes and 35 normal eyes were consecutively tested with the CVA after assessing best-corrected visual acuity (BCVA) using ETDRS charts. The CVA established visual thresholds for three mesopic environments (M1 (high contrast), M2 (medium contrast), and M3 (low contrast)) and three backlight-glare environments (G1 (high contrast, equivalent to ETDRS), G2 (medium contrast), and G3 (low contrast)) under timed conditions. Vision drop across environments was calculated, and repeatability of visual scores was determined. BCVA significantly reduced with decreasing contrast in all eyes. M1 scores for BCVA were greater than M2 and M3 (P<0.001); G1 scores were greater than G2 and G3 (P<0.01). BCVA dropped more in AMD eyes than in normal eyes between M1 and M2 (P=0.002) and between M1 and M3 (P=0.003). In AMD eyes, BCVA was better using ETDRS charts compared to G1 (P<0.001). The drop in visual function between ETDRS and G1 was greater in AMD eyes compared to normal eyes (P=0.004). Standard deviations of test-retest ranged from 0.100 to 0.139 logMAR. The CVA allowed analysis of the visual complaints that AMD patients experience with different lighting/contrast time-dependent conditions. BCVA changed significantly under different lighting/contrast conditions in all eyes, however, AMD eyes were more affected by contrast reduction than normal eyes. In AMD eyes, timed conditions using the CVA led to worse BCVA compared to non-timed ETDRS charts.
Kongsted, A; Jørgensen, L V; Bendix, T; Korsholm, L; Leboeuf-Yde, C
2007-11-01
To evaluate whether smooth pursuit eye movements differed between patients with long-lasting whiplash-associated disorders and controls when using a purely computerized method for the eye movement analysis. Cross-sectional study comparing patients with whiplash-associated disorders and controls who had not been exposed to head or neck trauma and had no notable neck complaints. Smooth pursuit eye movements were registered while the subjects were seated with and without rotated cervical spine. Thirty-four patients with whiplash-associated disorders with symptoms more than six months after a car collision and 60 controls. Smooth pursuit eye movements were almost identical in patients with chronic whiplash-associated disorders and controls, both when the neck was rotated and in the neutral position. Disturbed smooth pursuit eye movements do not appear to be a distinct feature in patients with chronic whiplash-associated disorders. This is in contrast to results of previous studies and may be due to the fact that analyses were performed in a computerized and objective manner. Other possible reasons for the discrepancy to previous studies are discussed.
Effect of rasanjana madhu ashchyotana in netra abhishyanda (mucopurulent conjunctivitis).
Bhardwaj, Atul; Tanwar, Manoj
2011-07-01
To evaluate the comparative efficacy of Ayurvedic formulation a Rasanjana Madhu (RM) eye drops and Honey Rose (HR) water eye drops in Netra Abhishyanda in mucopurulent conjunctivitis, the current study is planned. Total of 35 patients attending the outpatient department of Shalakya Tantra at R. G. G. Postgraduate Ayurvedic College, Paprola, Distt. Kangra, Himachal Pradesh with characteristic features of Netra Abhishyanda were selected for the present study. Twenty patients were given trial drug, i.e., RM eye drops, while 15 patients were given HR eye drops. Random sampling technique was adopted for the present study. The duration of the treatment was 7 days with 1 week follow-up. Patients receiving the trial group demonstrated reduction of redness, burning sensation, lacrimation, photophobia, foreign body sensation, discharge, and congestion, which were statistically significant with 93% patients cured or markedly improved category. Signs and symptoms stated above were also statistically reduced with HR eye drops, probably because of well-documented hygroscopic and bacteriocidal properties of honey. Based on the study, it can be concluded that, RM eye drops are very effective in the management of Netra Abhishyanda viz. Infective conjunctivitis.
Effect of Rasanjana Madhu Ashchyotana in Netra Abhishyanda (Mucopurulent Conjunctivitis)
Bhardwaj, Atul; Tanwar, Manoj
2011-01-01
To evaluate the comparative efficacy of Ayurvedic formulation a Rasanjana Madhu (RM) eye drops and Honey Rose (HR) water eye drops in Netra Abhishyanda in mucopurulent conjunctivitis, the current study is planned. Total of 35 patients attending the outpatient department of Shalakya Tantra at R. G. G. Postgraduate Ayurvedic College, Paprola, Distt. Kangra, Himachal Pradesh with characteristic features of Netra Abhishyanda were selected for the present study. Twenty patients were given trial drug, i.e., RM eye drops, while 15 patients were given HR eye drops. Random sampling technique was adopted for the present study. The duration of the treatment was 7 days with 1 week follow-up. Patients receiving the trial group demonstrated reduction of redness, burning sensation, lacrimation, photophobia, foreign body sensation, discharge, and congestion, which were statistically significant with 93% patients cured or markedly improved category. Signs and symptoms stated above were also statistically reduced with HR eye drops, probably because of well-documented hygroscopic and bacteriocidal properties of honey. Based on the study, it can be concluded that, RM eye drops are very effective in the management of Netra Abhishyanda viz. Infective conjunctivitis. PMID:22529652
Silva, Paolo S; Cavallerano, Jerry D; Sun, Jennifer K; Noble, Jason; Aiello, Lloyd M; Aiello, Lloyd Paul
2012-09-01
To compare nonmydriatic stereoscopic Optomap ultrawide field images with dilated stereoscopic Early Treatment Diabetic Retinopathy Study 7-standard field 35-mm color 30-degree fundus photographs (ETDRS photography) and clinical examination for determining diabetic retinopathy (DR) and diabetic macular edema (DME) severity. Single-site, prospective, comparative, instrument validation study. One hundred three diabetic patients (206 eyes) representing the full spectrum of DR severity underwent nonmydriatic ultrawide field 100-degree and 200-degree imaging, dilated ETDRS photography, and dilated fundus examination by a retina specialist. Two independent readers graded images to determine DR and DME severity. A third masked retina specialist adjudicated discrepancies. Based on ETDRS photography (n = 200), the results were as follows: no DR (n = 25 eyes [12.5%]), mild nonproliferative DR (NPDR; 47 [23.5%]), moderate NPDR (61 [30.5%]), severe NPDR (11 [5.5%]), very severe NPDR (3 [1.5%]), and proliferative DR (52 [2.5%]). One (0.5%) eye was ungradable and 6 eyes did not complete ETDRS photography. No DME was found in 114 eyes (57.0%), DME was found in 28 eyes (14.0%), and clinically significant DME was found in 47 eyes (23.5%), and 11 (5.5%) eyes were ungradable. Exact DR severity agreement between ultrawide field 100-degree imaging and ETDRS photography occurred in 84%, with agreement within 1 level in 91% (K(W) = 0.85; K = 0.79). Nonmydriatic ultrawide field images exactly matched clinical examination results for DR in 70% and were within 1 level in 93% (K(W) = 0.71; K = 0.61). Nonmydriatic ultrawide field imaging acquisition time was less than half that of dilated ETDRS photography (P < .0001). Nonmydriatic ultrawide field images compare favorably with dilated ETDRS photography and dilated fundus examination in determining DR and DME severity; however, they are acquired more rapidly. If confirmed in broader diabetic populations, nonmydriatic ultrawide field imaging may prove to be beneficial in DR evaluation in research and clinical settings. Copyright © 2012 Elsevier Inc. All rights reserved.
Kimmel, Daniel L.; Mammo, Dagem; Newsome, William T.
2012-01-01
From human perception to primate neurophysiology, monitoring eye position is critical to the study of vision, attention, oculomotor control, and behavior. Two principal techniques for the precise measurement of eye position—the long-standing sclera-embedded search coil and more recent optical tracking techniques—are in use in various laboratories, but no published study compares the performance of the two methods simultaneously in the same primates. Here we compare two popular systems—a sclera-embedded search coil from C-N-C Engineering and the EyeLink 1000 optical system from SR Research—by recording simultaneously from the same eye in the macaque monkey while the animal performed a simple oculomotor task. We found broad agreement between the two systems, particularly in positional accuracy during fixation, measurement of saccade amplitude, detection of fixational saccades, and sensitivity to subtle changes in eye position from trial to trial. Nonetheless, certain discrepancies persist, particularly elevated saccade peak velocities, post-saccadic ringing, influence of luminance change on reported position, and greater sample-to-sample variation in the optical system. Our study shows that optical performance now rivals that of the search coil, rendering optical systems appropriate for many if not most applications. This finding is consequential, especially for animal subjects, because the optical systems do not require invasive surgery for implantation and repair of search coils around the eye. Our data also allow laboratories using the optical system in human subjects to assess the strengths and limitations of the technique for their own applications. PMID:22912608
Galindo-Ferreiro, Alicia; De Miguel-Gutierrez, Julita; González-Sagrado, Manuel; Galvez-Ruiz, Alberto; Khandekar, Rajiv; Schellini, Silvana; Galindo-Alonso, Julio
2017-01-01
To present a method of screening for irregular astigmatism with an autorefractor and its determinants compared to corneal topography. This cross-sectional validity study was conducted in 2013 at an eye hospital in Spain. A tabletop autorefractor (test 1) was used to measure the refractive status of the anterior surface of the cornea at two corneal meridians of each eye. Then corneal topography (test 2) and Bogan's classification was used to group eyes into those with regular or no astigmatism (GRI) and irregular astigmatism (GRII). Test 1 provided a single absolute value for the greatest cylinder difference (Vr). The receiver operating characteristic (ROC) were plotted for the Vr values measured by test 1 for GRI and GRII eyes. On the basis a Vr value of 1.25 D as cut off, sensitivity, specificity were also calculated. The study sample was comprised of 260 eyes (135 patients). The prevalence of irregular astigmatism was 42% [95% confidence interval (CI): 36, 48]. Based on test 2, there were 151 eyes in GRI and 109 eyes in GRII. The median Vr was 0.75 D (25% quartile, 0.5 D) for GRI and 1.75 D (25% quartile, 1.25 D) for GRII. The area under curve was 0.171 for GRI and 0.83 for GRII. The sensitivity of test I was 78.1% and the specificity was 76.1%. A conventional autorefractor can be effective as a first level screening method to detect irregular corneal astigmatism in places where corneal topography facilities are not available.
A value-based medicine cost-utility analysis of idiopathic epiretinal membrane surgery.
Gupta, Omesh P; Brown, Gary C; Brown, Melissa M
2008-05-01
To perform a reference case, cost-utility analysis of epiretinal membrane (ERM) surgery using current literature on outcomes and complications. Computer-based, value-based medicine analysis. Decision analyses were performed under two scenarios: ERM surgery in better-seeing eye and ERM surgery in worse-seeing eye. The models applied long-term published data primarily from the Blue Mountains Eye Study and the Beaver Dam Eye Study. Visual acuity and major complications were derived from 25-gauge pars plana vitrectomy studies. Patient-based, time trade-off utility values, Markov modeling, sensitivity analysis, and net present value adjustments were used in the design and calculation of results. Main outcome measures included the number of discounted quality-adjusted-life-years (QALYs) gained and dollars spent per QALY gained. ERM surgery in the better-seeing eye compared with observation resulted in a mean gain of 0.755 discounted QALYs (3% annual rate) per patient treated. This model resulted in $4,680 per QALY for this procedure. When sensitivity analysis was performed, utility values varied from $6,245 to $3,746/QALY gained, medical costs varied from $3,510 to $5,850/QALY gained, and ERM recurrence rate increased to $5,524/QALY. ERM surgery in the worse-seeing eye compared with observation resulted in a mean gain of 0.27 discounted QALYs per patient treated. The $/QALY was $16,146 with a range of $20,183 to $12,110 based on sensitivity analyses. Utility values ranged from $21,520 to $12,916/QALY and ERM recurrence rate increased to $16,846/QALY based on sensitivity analysis. ERM surgery is a very cost-effective procedure when compared with other interventions across medical subspecialties.
ERIC Educational Resources Information Center
Yeari, Menahem; van den Broek, Paul; Oudega, Marja
2015-01-01
The present study examined the effect of reading goals on the processing and memory of central and peripheral textual information. Using eye-tracking methodology, we compared the effect of four common reading goals--entertainment, presentation, studying for a close-ended (multiple-choice) questions test, and studying for an open-ended questions…
Adhi, Mehreen; Filho, Marco A Bonini; Louzada, Ricardo N; Kuehlewein, Laura; de Carlo, Talisa E; Baumal, Caroline R; Witkin, Andre J; Sadda, Srinivas R; Sarraf, David; Reichel, Elias; Duker, Jay S; Waheed, Nadia K
2016-07-01
To evaluate the perifoveolar retinal capillary network at different depths and to quantify the foveal avascular zone (FAZ) in eyes with retinal vein occlusion (RVO) compared with their fellow eyes and healthy controls using spectral-domain optical coherence tomography angiography (SD-OCTA). We prospectively recruited 23 patients with RVO including 15 eyes with central RVO (CRVO) and 8 eyes with branch RVO (BRVO), their fellow eyes, and 8 age-matched healthy controls (8 eyes) for imaging on prototype OCTA software within RTVue-XR Avanti. The 3 × 3 mm and 6 × 6 mm en face angiograms of superficial and deep retinal capillary plexuses were segmented. Perifoveolar retinal capillary network was analyzed and FAZ was quantified. Decrease in vascular perfusion at the deep plexus was observed in all eyes with CRVO (8/8, 100%) and BRVO (6/6, 100%) without cystoid macular edema, and in 8 of 15 (53%) and 2 of 8 (25%) of the fellow eyes, respectively. Vascular tortuosity was observed in 13 of 15 (87%) CRVO and 5 of 8 (63%) BRVO eyes. Collaterals were seen in 10 of 15 (67%) CRVO and 5 of 8 (63%) BRVO eyes. Mean FAZ area was larger in eyes with RVO than their fellow eyes (1.13 ± 0.25 mm2 versus 0.58 ± 0.28 mm2; P = 0.007) and controls (1.13 ± 0.25 mm2 versus 0.30 ± 0.09 mm2; P < 0.0001), and in fellow eyes of RVO patients when compared to controls (0.58 ± 0.28 mm2 versus 0.30 ± 0.09 mm2; P = 0.01). Spectral-domain OCTA reveals abnormalities at different levels of perifoveolar retinal capillary network and is able to quantify the FAZ in RVO. Longitudinal studies may be considered to evaluate the clinical utility of OCTA in RVO and other retinal vascular diseases.
Mansouri, Mohammadreza; Ramezani, Farshid; Moghimi, Sasan; Tabatabaie, Ali; Abdi, Fatemeh; He, Mingguang; Lin, Shan C
2014-10-21
To describe anterior segment optical coherence tomography (AS-OCT) parameters in phacomorphic angle closure eyes, mature cataract eyes, and their fellow eyes, and identify those parameters that could be used to differentiate phacomorphic angle closure eyes from those with mature cataract and no phacomorphic angle closure. In this cross-sectional study, a total of 33 phacomorphic angle closure subjects and 34 control patients with unilateral mature cataracts were enrolled. All patients underwent AS-OCT imaging and A-scan biometry of both eyes. Anterior chamber depth (ACD), anterior chamber area (ACA), iris thickness, iris curvature, lens vault (LV), and angle parameters, including angle opening distance (AOD750) and trabecular-iris space area (TISA750), were measured in qualified images using customized software and compared among eyes with phacomorphic angle closure, mature cataract eyes, and their fellow eyes. There was no significant difference in axial length among the four groups. Phacomorphic angle closure had the smallest angle (AOD750, TISA750) and anterior chamber parameters (ACD, ACA, anterior chamber width) and the greatest LV among the groups. This pattern was similar when comparing fellow eyes of mature cataract patients and fellow eyes of phacomorphic angle closure. Anterior chamber area less than 18.62 mm(2), ACD less than 2.60 mm, LV greater than 532.0 μm, and AOD750 less than 0.218 mm had the highest odds ratios (ORs) for distinguishing fellow eyes of phacomorphic angle closure versus fellow eyes of mature cataracts, with OR values of 9.90, 8.31, 7.91, and 7.91, respectively. Logistic regression showed that ACA less than 18.62 was the major parameter associated with fellow eyes of phacomorphic angle closure (OR = 10.96, P < 0.001). Anterior chamber depth, ACA, AOD750, and LV are powerful indicators in differentiating phacomorphic angle closure eyes from those with mature cataract and their fellow eyes. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.
Specialized moisture retention eyewear for evaporative dry eye.
Waduthantri, Samanthila; Tan, Chien Hua; Fong, Yee Wei; Tong, Louis
2015-05-01
To evaluate the suitablity of commercially available moisture retention eyewear for treating evaporative dry eye. Eleven patients with evaporative dry eyes were prescibed moisture retention eyewear for 3 months in addition to regular lubricant eye drops. Frequency and severity of dry eye symptoms, corneal fluorescein staining and tear break up time (TBUT) were evaluated at baseline and 3-month post-treatment. Main outcome measure was global symptom score (based on severity and frequency of dry eye symptoms on a visual analog scale) and secondary outcomes were changes in sectoral corneal fluorescein staining and tear break up time (TBUT) from pre-treatment level. There was a significant improvement in dry eye symptoms after using moisture retention eyewear for 3 months (p < 0.05). Corneal fluorescein staining in all five zones of the cornea in both eyes improved significantly (p < 0.05). There was no significant improvement in TBUT. Patients used ocular lubricants less frequently (p < 0.05) compared to the commencement of the study. Patients found moisture retention eyewear to be useful in relieving dry eye symptoms in windy, air-conditioned environments or when doing vision-related daily tasks. This study shows that moisture retention eyewear might be a valuable adjunct in management of evaporative dry eye and this new design of commercially available eyewear could have a good acceptability rate.
Scanning mid-IR laser apparatus with eye tracking for refractive surgery
NASA Astrophysics Data System (ADS)
Telfair, William B.; Yoder, Paul R., Jr.; Bekker, Carsten; Hoffman, Hanna J.; Jensen, Eric F.
1999-06-01
A robust, real-time, dynamic eye tracker has been integrated with the short pulse mid-infrared laser scanning delivery system previously described. This system employs a Q- switched Nd:YAG laser pumped optical parametric oscillator operating at 2.94 micrometers. Previous ablation studies on human cadaver eyes and in-vivo cat eyes demonstrated very smooth ablations with extremely low damage levels similar to results with an excimer. A 4-month healing study with cats indicated no adverse healing effects. In order to treat human eyes, the tracker is required because the eyes move during the procedure due to both voluntary and involuntary motions such as breathing, heartbeat, drift, loss of fixation, saccades and microsaccades. Eye tracking techniques from the literature were compared. A limbus tracking system was best for this application. Temporal and spectral filtering techniques were implemented to reduce tracking errors, reject stray light, and increase signal to noise ratio. The expanded-capability system (IRVision AccuScan 2000 Laser System) has been tested in the lab on simulated eye targets, glass eyes, cadaver eyes, and live human subjects. Circular targets ranging from 10-mm to 14-mm diameter were successfully tracked. The tracker performed beyond expectations while the system performed myopic photorefractive keratectomy procedures on several legally blind human subjects.
The safety of intraocular methotrexate in silicone-filled eyes.
Hardwig, Paul W; Pulido, Jose S; Bakri, Sophie J
2008-10-01
Intraocular methotrexate has been safely used in eyes with primary CNS lymphoma (PCNSL), and in eyes with uveitis and proliferative diabetic retinopathy. Dosing in silicone-filled eyes was reduced from a standard 400 microg intravitreal injection due to concerns of toxicity. The present study reports the visual results of non-PCNSL, silicone-filled eyes treated with intravitreal methotrexate using cumulative dosages ranging from 200 microg to 1,200 microg. In this retrospective case series, all patients with silicone-filled eyes who received intraocular methotrexate were included. Patients were observed with serial ophthalmic examinations. Best-corrected visual acuity was measured by Snellen acuity. Pretreatment acuities were compared to those obtained at last follow-up. The cohort included 12 patients (13 eyes) with disease other than PCNSL. The cumulative dose of intraocular methotrexate in any one patient ranged from 200 microg to 1,200 microg. Mean follow-up was 9 months (median, 10 months; range, 2 weeks to 16 months). Best-corrected vision at last follow-up was either stable or improved from pretreatment acuity in 12 of 13 eyes. Preservation of acuity in 12 of 13 study eyes suggests that intravitreal methotrexate in a cumulative dose of up to 1,200 microg is safe in silicone-filled eyes.
Farid, Marjan; Chak, Garrick; Garg, Sumit; Steinert, Roger F
2014-08-01
To evaluate differences in mean deviation values in automated perimetry in healthy eyes with multifocal compared to monofocal intraocular lens (IOL) implants. Prospective, age-matched, comparative analysis. Single-center, tertiary referral academic practice. A total of 37 healthy eyes in 37 patients with bilateral multifocal (n=22) or monofocal (n=15) IOL implants were studied. INTERVENTION/OBSERVATION PROCEDURE: Humphrey Visual Field 10-2 testing was performed on all patients. Mean deviation (MD) and pattern standard deviation (PSD) numerical values were evaluated and compared between groups. The average MD was -2.84 dB (SD 2.32) for the multifocal IOL group and -0.97 dB (SD 1.58) for the monofocal IOL group (P=.006). There was no significant difference in PSD between the 2 groups (P=.99). Eyes that had the visual field 10-2 testing≥6 months from time of IOL placement showed no improvement in MD when compared to eyes that were tested within 6 months from IOL placement. Multifocal IOL implants cause significant nonspecific reduction in MD values on Humphrey Visual Field 10-2 testing that does not improve with time or neuroadaptation. Multifocal IOL implants may be inadvisable in patients where central visual field reduction may not be tolerated, such as macular degeneration, retinal pigment epithelium changes, and glaucoma. Copyright © 2014 Elsevier Inc. All rights reserved.
Vilaseca, Meritxell; Romero, Maria José; Arjona, Montserrat; Luque, Sergio Oscar; Ondategui, Juan Carlos; Salvador, Antoni; Güell, José L; Artal, Pablo; Pujol, Jaume
2012-09-01
To evaluate objectively intraocular scattering in eyes with nuclear, cortical and posterior subcapsular cataracts by means of an objective scatter index (OSI) obtained from double-pass images. To compare the results with those obtained using clinical conventional procedures. In this prospective, observational, cross-sectional, non-consecutive case series study, 188 eyes with cataracts of 136 patients were analysed (123 eyes had nuclear, 41 eyes had cortical and 24 eyes had posterior subcapsular cataracts). The control group consisted of 117 eyes of 68 healthy patients. Patient examination included subjective refraction, best spectacle-corrected visual acuity (BSCVA), cataract grade using the lens opacities classification system III (LOCS III) and OSI. We found a decrease in the BSCVA and an increase in the OSI with increasing cataract grade. Statistically significant differences were observed when the OSI of eyes without cataracts and those with different LOCS III were compared. The comparison between the OSI and LOCS III reported good percentages of agreement regarding the number of eyes classified in equivalent levels: 72.4% (nuclear cataracts), 86.6% (cortical cataracts) and 84.3% (posterior subcapsular cataracts). A non-linear regression model was applied between OSI and BSCVA, which resulted in the following multiple correlation coefficients: r=0.878 (nuclear), r=0.843 (cortical) and r=0.844 (posterior subcapsular). The results of the study showed that OSI is a useful parameter for evaluating large amounts of intraocular scattering that can be used, in combination with other conventional procedures, as a valuable tool in clinical practice to grade cataracts objectively.
Ashraf, Mohammed; Souka, Ahmed; Adelman, Ron A
2017-09-01
To study the effect of the vitreomacular interface on various wet age-related macular degeneration (AMD) characteristics including the size and type of choroidal neovascularization (CNV), choroidal thickness, and activity of the CNV. This was a retrospective observational cross-sectional study. The study included 43 patients (51 eyes) with treatment-naive age-related macular degeneration. Twenty-six patients with wet AMD in one eye and dry AMD in the other eye were included in a paired-eye analysis. Patients underwent optical coherence tomography examination using Heidelberg Spectralis (spectral domain optical coherence tomography) at presentation to determine the type of CNV and the vitreomacular status. In addition, various parameters were measured including the choroidal thickness and horizontal width and vertical height measurements of the CNV. There was no correlation between the height, width, activity or type of the CNV, and the presence or absence of vitreomacular adhesion. The mean choroidal thickness (using enhanced depth imaging) in cases with vitreomacular adhesion was 272.57 μm compared with 197.32 μm in cases with no vitreomacular adhesion, a statistically significant difference (P = 0.003). In the paired-eye study (21 patients), there was no significant difference between the eyes with wet AMD and dry AMD with regard to vitreomacular status or the choroidal thickness. In a subgroup analysis, patients with Type 1 CNV had a significantly higher percentage of vitreomacular adhesion compared with the other eye with dry AMD (P = 0.034). In conclusion, the vitreomacular interface does seem to be associated with an increased choroidal thickness in cases of wet AMD. Furthermore, the association between the vitreomacular interface and wet AMD is more significant for Type 1 CNV.
Kusbeci, Tuncay; Karti, Omer; Karahan, Eyyup; Oguztoreli, Mustafa
2017-12-01
To investigate whether macular anatomic structure and afferent visual system function differ among amblyopic eyes, non-amblyopic fellow eyes, and controls, using spectral-domain optical coherence tomography (SD-OCT), and pupil cycle time (PCT). This observational, cross-sectional study included 30 patients with unilateral amblyopia and 30 healthy subjects. Optical coherence tomography (OCT) and pupil cycle time (PCT) were used to evaluate patients with unilateral amblyopia and were compared with their non-amblyopic fellow eyes and age- and gender-matched healthy eyes (30 participants). The amblyopic eyes were separated into two groups: anisometropic amblyopia (n = 16) and strabismic amblyopia (n = 14). OCT maps were used to calculate central macular thickness (CMT), retinal nerve fiber layer thickness (RNFLT), and ganglion cell-inner plexiform layer (GC-IPL) thickness. The average RNFLT, GC-IPL thickness, and CMT did not show any significant differences among the amblyopic eyes, non-amblyopic fellow eyes and controls (p > 0.05, Kruskal-Wallis test). Mean PCT was 773.57 ± 64 msn in strabismic eyes, 771.25 ± 58 msn in anisometropic eyes, 778.00 ± 72 msn in non-amblyopic fellow eyes, and 774.75 ± 69 msn in control eyes. The differences among the amblyopic eyes, its fellow and control eyes were not statistically significant (p > 0.05, Kruskal-Wallis test). In this study, we investigated morphological and functional differences among amblyopic eyes, non-amblyopic fellow eyes and controls by using SD-OCT and PCT. We did not find anatomical or functional changes in amblyopic eyes.
Hammel, Naama; Belghith, Akram; Weinreb, Robert N; Medeiros, Felipe A; Mendoza, Nadia; Zangwill, Linda M
2017-06-01
To compare the rates of circumpapillary retinal nerve fiber layer (RNFL) and macular retinal ganglion cell-inner plexiform layer (GCIPL) change over time in healthy and glaucoma eyes. Cohort study. The rates of circumpapillary RNFL and macular GCIPL loss in 28 healthy subjects and 97 glaucoma subjects from the Diagnostic Innovations in Glaucoma Study (DIGS) were compared using mixed-effects models. The median follow-up time and number of visits were 1.7 years and 6 visits and 3.2 years and 7 visits for healthy and glaucoma eyes, respectively. Significant rates of loss of both global circumpapillary RNFL and average macular GCIPL thickness were detectable in early and moderate glaucoma eyes; in severe glaucoma eyes, rates of average macular GCIPL loss were significant, but rates of global circumpapillary RNFL loss were not. In glaucoma eyes, mean rates of global circumpapillary RNFL thickness change (-0.98 μm/year [95% confidence interval (CI), -1.20 to -0.76]) and normalized global circumpapillary RNFL change (-1.7%/year [95% CI, -2.1 to -1.3]) were significantly faster than average macular GCIPL change (-0.57 μm/year [(95% CI, -0.73 to -0.41]) and normalized macular GCIPL change (-1.3%/year [95% CI, -1.7 to -0.9]). The rates of global and inferior RNFL change were weakly correlated with global and inferior macular GCIPL change (r ranges from 0.16 to 0.23, all P < .05). In this cohort, the rate of circumpapillary RNFL thickness change was faster than macular GCIPL change for glaucoma eyes. Global circumpapillary RNFL thickness loss was detectable in early and moderate glaucoma, and average macular GCIPL thickness loss was detectable in early, moderate, and severe glaucoma, suggesting that structural changes can be detected in severe glaucoma. Copyright © 2017 Elsevier Inc. All rights reserved.
Outcome of corneal and laser astigmatic axis alignment in photoastigmatic refractive keratectomy.
Farah, S G; Olafsson, E; Gwynn, D G; Azar, D T; Brightbill, F S
2000-12-01
To compare the refractive results of laser astigmatic treatment in eyes in which the astigmatic axes of the eye and laser are aligned by limbal marking at the 6 o'clock position and in eyes that are not marked. University Hospital and Clinics, Madison, Wisconsin, USA. This retrospective study comprised 143 eyes that had photoastigmatic refractive keratectomy with the VISX Star excimer laser. The eyes were divided into marked (G1) and unmarked (G2) groups. Based on the preoperative astigmatism, each group was subdivided into low astigmatism (=1.00 diopter [D]) and high astigmatism (>/=1.25 D). Early postoperative manifest refractions (1.0 to 2.5 months) were analyzed. The Alpins vector analysis method was used to calculate the target induced astigmatism, surgically induced astigmatism, difference vector (DV), magnitude of error (ME), angle of error (AE), and index of success (IS). There was no significant difference between the groups in DV, ME, and IS. When the subgroups were analyzed, the DV and ME were comparable; the IS in the G1 high astigmatism subgroup was significantly better than that in the G2 high astigmatism subgroup (0.22 +/- 0.08 and 0.29 +/- 0.04, respectively; P <.0001). There was comparable scatter of AE values; 30% and 36% in G1 and G2, respectively, had an AE of 0. Similar scatter was observed in the subgroups. Of the eyes that had an AE of 0, 90% and 43% in the high astigmatism subgroups of G1 and G2, respectively (P <.05), had full correction of astigmatism. Limbal marking and subsequent eye and laser astigmatic axis alignment improved the refractive outcome of laser astigmatic treatment of >/=1.25 D. A preliminary report of an ongoing prospective randomized study of eyes that had laser in situ keratomileusis is included.
Prevalence of Dry Eye in Uyghur and Han Ethnic Groups in Western China.
Gong, Ying-Ying; Zhang, Fan; Zhou, Jin; Li, Jing; Zhang, Guang-Hui; Wang, Jun-Liang; Gu, Zhen-Sheng
2017-06-01
To describe and compare the prevalence and characteristics of dry eye among Han and Uyghur persons living in Kashi, the most inland city of China. A total of 1015 residents of Kashi participated in this 2013 cross-sectional study. To evaluate clinical characteristics, each subject completed (1) a dry-eye questionnaire detailing symptoms of dry eye, (2) Schirmer's I-test (SIT), (3) tear-film break-up time (BUT) test, and fluorescein staining of the cornea. Dry eye was defined as the existence of dry eye symptoms and at least two positive clinical signs. Data were analyzed using SPSS software. The prevalence and risk factors of dry eye were evaluated using a multivariate model. Overall, 282 (27.8%) of the 1015 participants were diagnosed with dry eye (95% confidence interval (CI): range, 25.5-30.1). The prevalence of dry eye among Han persons (37.9 %) (95% CI: range, 35.8-40.0) was higher than that among Uyghurs (21.8%) (95% CI: 19.6-24.0) (p < 0.05). The prevalence of dry eye was 25.6% (95% CI: range, 23.3-27.8) among men and 28.7% (95% CI: 26.5-30.9) among women (p > 0.05). Risk factors for dry eye included ethnicity, age, occupation, arthritis, and dry mouth. Our study revealed a higher prevalence of dry eye among Han than Uyghur persons in Kashi. Dry eye was significantly associated with environment and ethnicity.
Neustein, Rebecca F; Beck, Allen D
2017-11-01
This study compares the long-term efficacy of circumferential trabeculotomy to that of conventional angle surgeries in primary congenital glaucoma (PCG), as judged by glaucoma and visual outcomes. Retrospective observational case series. Setting: Emory Eye Center, Atlanta, Georgia. This was a single-institution retrospective study involving children with PCG who underwent circumferential trabeculotomy, standard trabeculotomy, or goniotomy with ≥2-year follow-up. Postoperative success (intraocular pressure [IOP] < 22 mm Hg ± glaucoma medications, without glaucoma progression/additional IOP-lowering surgery), Snellen-equivalent visual acuity (VA), and IOP at last follow-up. Kaplan-Meier method estimated the probability of glaucoma control vs time postoperatively, and values were compared between angle surgery cohorts using Wilcoxon signed rank tests, Mann-Whitney U tests, and Fisher exact tests. Included were 58 eyes (33 children) after circumferential trabeculotomy and 42 eyes (27 children) after standard trabeculotomy/goniotomy, with mean follow-up of 7.2 ± 4.0 and 8.2 ± 4.5 years, respectively. Postoperative success at last follow-up in the circumferential vs conventional cohorts was 81% (47 of 58 eyes) vs 31% (13 of 42 eyes) (P < .0001). At last follow-up, the circumferential cohort had better median VA than the conventional cohort (20/30 (interquartile range [IQR] 20/25 to 20/70) vs 20/70 (IQR 20/40 to 20/200), P = .009), required fewer glaucoma medications (0.55 ± 1.2 vs 1.61 ± 1.51, P < .0001), had lower IOP in first operated eye (15.2 ± 3.6 vs 18.2 ± 7.0, P = .048), and had comparable incidence of devastating complications (P = .065). In this retrospective study, circumferential trabeculotomy afforded better long-term success and visual outcomes than conventional angle surgery for children with PCG. Copyright © 2017 Elsevier Inc. All rights reserved.
King, Roderick; Hanhan, Jaber; Harrison, T Kyle; Kou, Alex; Howard, Steven K; Borg, Lindsay K; Shum, Cynthia; Udani, Ankeet D; Mariano, Edward R
2018-05-15
Malignant hyperthermia is a rare but potentially fatal complication of anesthesia, and several different cognitive aids designed to facilitate a timely and accurate response to this crisis currently exist. Eye tracking technology can measure voluntary and involuntary eye movements, gaze fixation within an area of interest, and speed of visual response and has been used to a limited extent in anesthesiology. With eye tracking technology, we compared the accessibility of five malignant hyperthermia cognitive aids by collecting gaze data from twelve volunteer participants. Recordings were reviewed and annotated to measure the time required for participants to locate objects on the cognitive aid to provide an answer; cumulative time to answer was the primary outcome. For the primary outcome, there were differences detected between cumulative time to answer survival curves (P < 0.001). Participants demonstrated the shortest cumulative time to answer when viewing the Society for Pediatric Anesthesia (SPA) cognitive aid compared to four other publicly available cognitive aids for malignant hyperthermia, and this outcome was not influenced by the anesthesiologists' years of experience. This is the first study to utilize eye tracking technology in a comparative evaluation of cognitive aid design, and our experience suggests that there may be additional applications of eye tracking technology in healthcare and medical education. Potentially advantageous design features of the SPA cognitive aid include a single page, linear layout, and simple typescript with minimal use of single color blocking.
Pharmacologic Plus Optical Penalization Treatment for Amblyopia: Results of a Randomized Trial
2008-01-01
Objective To compare weekend atropine augmented by a plano lens for the sound eye with weekend atropine alone for moderate amblyopia in children 3 to <7 years old. Methods In a multi-center clinical trial, 180 children with moderate amblyopia (20/40 to 20/100) were randomized to weekend atropine augmented by a plano lens or weekend atropine alone. Main Outcome Measure Masked assessment of amblyopic eye visual acuity using the Amblyopia Treatment Study HOTV testing protocol at 18 weeks. Results At 18 weeks, amblyopic eye improvement averaged 2.8 lines in the atropine plus plano lens group and 2.4 lines in the atropine alone group (mean difference between groups adjusted for baseline acuity 0.3 lines; 95% confidence interval, −0.2 to 0.8). Amblyopic eye acuity was 20/25 or better in 24 (29%) patients in the atropine-only group and 35 (40%) patients in the atropine plus plano lens group (P=0.03). More patients in the atropine plus plano lens group had reduced sound eye acuity at 18 weeks; however, there were no cases of persistent reverse amblyopia. Conclusions As an initial treatment for moderate amblyopia, the augmentation of weekend atropine with a plano lens does not substantially improve amblyopic eye acuity when compared with atropine alone. Application to Clinical Practice Treatment of children with unilateral amblyopia Trial Registry Name Trial Comparing Atropine to Atropine Plus a Plano Lens for the Sound Eye for Amblyopia in Children 3 to <7 Years Old PMID:19139333
Attention-Related Eye Vergence Measured in Children with Attention Deficit Hyperactivity Disorder
Solé Puig, Maria; Pérez Zapata, Laura; Puigcerver, Laura; Esperalba Iglesias, Neus; Sanchez Garcia, Carmen; Romeo, August; Cañete Crespillo, Josep; Supèr, Hans
2015-01-01
Recent evidence shows a novel role for eye vergence in orienting attention in adult subjects. Here we investigated whether such modulation in eye vergence by attention is present in children and whether it is altered in children with ADHD compared to control subjects. We therefore measured the angle of eye vergence in children previously diagnosed with ADHD while performing a cue task and compared the results to those from age-matched controls. We observed a strong modulation in the angle of vergence in the control group and a weak modulation in the ADHD group. In addition, in the control group the modulation in eye vergence was different between the informative cue and uninformative cue condition. This difference was less noticeable in the ADHD group. Our study supports the observation of deficient binocular vision in ADHD children. We argue that the observed disruption in vergence modulation in ADHD children is manifest of altered cognitive processing of sensory information. Our work may provide new insights into attention disorders, like ADHD. PMID:26694162
Narendran, Siddharth; Manayath, George; Venkatapathy, Narendran
2018-01-01
Choroidal thickness measurements are reported to differ between spectral-domain optical coherence tomography (SD-OCT) and swept-source OCT (SS-OCT). The aim of this study was to assess the comparability of choroidal thickness measurements using SS-OCT and SD-OCT devices among normal participants. This was a prospective study of 31 (62 eyes) normal participants. Choroidal imaging was performed sequentially with the Spectralis OCT (SD-OCT) and the deep range imaging OCT (DRI OCT-1) (SS-OCT) using standardized imaging protocols. The subfoveal choroidal thickness (SFChT) was measured manually by two masked retinal specialists. Paired t -tests and intraclass correlation coefficients (ICCs) were used to compare the measurements. The mean SFChT was 319.5 μm and 325.3 μm for DRI OCT-1 and Spectralis OCT, respectively ( P = 0.001), with a mean difference of 5.9 with ICC of 0.97. The mean difference in choroidal thickness between the OCT devices was larger among eyes with choroidal thickness > 350 μm compared with eyes with thinner choroids (8.0 μm vs. 4.7 μm). SFChT measurements are comparable between DRI OCT-1 and Spectralis OCT. The variability between the devices increases in thicker choroids.
ERIC Educational Resources Information Center
Falkmer, Marita; Bjallmark, Anna; Larsson, Matilda; Falkmer, Torbjorn
2011-01-01
Several studies, using eye tracking methodology, suggest that different visual strategies in persons with autism spectrum conditions, compared with controls, are applied when viewing facial stimuli. Most eye tracking studies are, however, made in laboratory settings with either static (photos) or non-interactive dynamic stimuli, such as video…
Intraocular lens design for treating high myopia based on individual eye model
NASA Astrophysics Data System (ADS)
Wang, Yang; Wang, Zhaoqi; Wang, Yan; Zuo, Tong
2007-02-01
In this research, we firstly design the phakic intraocular lens (PIOL) based on individual eye model with optical design software ZEMAX. The individual PIOL is designed to correct the defocus and astigmatism, and then we compare the PIOL power calculated from the individual eye model with that from the experiential formula. Close values of PIOL power are obtained between the individual eye model and the formula, but the suggested method has more accuracy with more functions. The impact of PIOL decentration on human eye is evaluated, including rotation decentration, flat axis decentration, steep axis decentration and axial movement of PIOL, which is impossible with traditional method. To control the PIOL decentration errors, we give the limit values of PIOL decentration for the specific eye in this study.
Boberg-Ans, G; Nissen, K R
1998-02-01
To compare the healing of the cornea and the incidence of infection after traumatic corneal epithelial defect after single treatment with double bandage combined with either Fucithalmic single unit dose eye drops or chloramphenicol eye ointment. This is a single-centre, randomised, single-blind, parallel-group study of 144 patients with accidental corneal abrasion or corpus alieni cornea who were referred to the Eye Department at Gentofte Hospital. The injured eye was examined with a photo slit-lamp before and 24 hours after treatment. The size of the abrasion was recorded and calculated on a PCX computerized video system and by slit-lamp photography. The Fucithalmic and chloramphenicol ointment treated groups showed no significant difference in corneal healing, local side effects, or signs of local infection.
[Eyes test performance among unaffected mothers of patients with schizophrenia].
Birdal, Seval; Yıldırım, Ejder Akgün; Arslan Delice, Mehtap; Yavuz, Kasım Fatih; Kurt, Erhan
2015-01-01
Theory of Mind (ToM) deficit is a widely accepted feature of schizophrenia. A number of studies have examined ToM deficits of first degree relatives of schizophrenic patients as genetic markers of schizophrenia. Examination of mentalization capacity among mothers of schizophrenia patients may improve our understanding of theory of mind impairments in schizophrenia. The aim of this study is to use Reading Mind in the Eyes test to examine theory of mind capacity among mothers of schizophrenic patients. Performance during the test "Reading the Mind in the Eyes" (Eyes Test) was compared between the mothers of schizophrenic patients (n=47) and mothers whose children have no psychotic mental illness (n=47). Test results were analyzed based on the categorization of test items as positive, negative, and neutral. Mothers of schizophrenic patients displayed poorer performance during the Eyes Test compare to mothers in the control group, particularly in the recognition of positive and neutral mental representations. There was no statistically significant difference in the recognition of negative mental representations between mothers of patients and the control groups. The results of this study indicate that mothers of schizophrenic patients differ in some theory of mind patterns. Theory of mind may be an important developmental or endophenotipic factor in the pathogenesis of schizophrenia and should be further evaluated using other biological markers.
A pilot study: the efficacy of virgin coconut oil as ocular rewetting agent on rabbit eyes.
Mutalib, Haliza Abdul; Kaur, Sharanjeet; Ghazali, Ahmad Rohi; Chinn Hooi, Ng; Safie, Nor Hasanah
2015-01-01
Purpose. An open-label pilot study of virgin coconut oil (VCO) was conducted to determine the safety of the agent as ocular rewetting eye drops on rabbits. Methods. Efficacy of the VCO was assessed by measuring NIBUT, anterior eye assessment, corneal staining, pH, and Schirmer value before instillation and at 30 min, 60 min, and two weeks after instillation. Friedman test was used to analyse any changes in all the measurable variables over the period of time. Results. Only conjunctival redness with instillation of saline agent showed significant difference over the period of time (P < 0.05). However, further statistical analysis had shown no significant difference at 30 min, 60 min, and two weeks compared to initial measurement (P > 0.05). There were no changes in the NIBUT, limbal redness, palpebral conjunctiva redness, corneal staining, pH, and Schirmer value over the period of time for each agent (P > 0.05). Conclusion. VCO acts as safe rewetting eye drops as it has shown no significant difference in the measurable parameter compared to commercial brand eye drops and saline. These study data suggest that VCO is safe to be used as ocular rewetting agent on human being.
A Pilot Study: The Efficacy of Virgin Coconut Oil as Ocular Rewetting Agent on Rabbit Eyes
Mutalib, Haliza Abdul; Kaur, Sharanjeet; Ghazali, Ahmad Rohi; Chinn Hooi, Ng; Safie, Nor Hasanah
2015-01-01
Purpose. An open-label pilot study of virgin coconut oil (VCO) was conducted to determine the safety of the agent as ocular rewetting eye drops on rabbits. Methods. Efficacy of the VCO was assessed by measuring NIBUT, anterior eye assessment, corneal staining, pH, and Schirmer value before instillation and at 30 min, 60 min, and two weeks after instillation. Friedman test was used to analyse any changes in all the measurable variables over the period of time. Results. Only conjunctival redness with instillation of saline agent showed significant difference over the period of time (P < 0.05). However, further statistical analysis had shown no significant difference at 30 min, 60 min, and two weeks compared to initial measurement (P > 0.05). There were no changes in the NIBUT, limbal redness, palpebral conjunctiva redness, corneal staining, pH, and Schirmer value over the period of time for each agent (P > 0.05). Conclusion. VCO acts as safe rewetting eye drops as it has shown no significant difference in the measurable parameter compared to commercial brand eye drops and saline. These study data suggest that VCO is safe to be used as ocular rewetting agent on human being. PMID:25802534
Batman, C; Ozdamar, Y; Mutevelli, S; Sonmez, K; Zilelioglu, G; Karakaya, J
2009-06-01
To describe the use of tissue glue to close scleral and conjunctival wounds, and to compare the clinical outcomes using tissue glue and vicryl suture for closing these areas in conventional 20-gauge (G) vitrectomy. Thirty eyes of 30 patients were included in this study. The indications for vitreoretinal surgery were diabetic vitreous haemorrhage with severe vitreoretinal traction in 10 eyes, retinal detachment and proliferative vitreoretinopathy in 14 eyes, and vitreous opacity in 6 eyes. Tissue glue (Tisseel, Baxter AG Industries, Vienna, Austria) was used to attach scleral and conjunctival wounds in 15 eyes and vicryl sutures in 15 eyes. The patients were allotted into two subgroups as tissue glue group (TG) and vicryl suture group (VG). The sclerotomy sites were evaluated with ultrasound biomicroscopy (UBM) postoperatively in TG. Follow-up period was 2 months. The groups were statistically compared for ocular signs and symptoms by Mann-Whitney U-test. No scleral wound leakage and conjunctival reattachment were observed at the end of the surgical procedure and during the follow-up period. No adverse effects were seen in TG. Abnormal fibrous ingrowth was not detected at the sclerotomy sites by means of UBM in TG. Patient comfort was significantly higher in TG than VG (P<0.05). Tissue glue has no adverse effects on ocular tissue and can be used as a substitute for suture materials, and the use of tissue glue decreases patient symptoms during the postoperative period after 20-G vitrectomy. Tissue glue can enable to perform sutureless surgery in the conventional 20-G vitrectomy.
Chin, Eric K; Ventura, Bruna V; See, Kai-Yin; Seibles, Joann; Park, Susanna S
2014-02-01
To evaluate the relative diagnostic value of nonmydriatic fundus photography (nFP) among patients screened for diabetic retinopathy in remote rural medical clinics and an urban academic medical center for nonadherence to recommended annual dilated eye examination. A retrospective cross-sectional study was performed among diabetic patients seen in primary outpatient clinics between 2006 and 2011 who were screened for diabetic retinopathy with nFP for history of nonadherence to recommended annual dilated eye examination. A single nonstereoscopic, 45°, 10-megapixel digital image of the disc and macula of both eyes was obtained locally and transmitted electronically to a retinal specialist for remote review. The results from remote rural Native American Indian reservations were compared with those from an urban academic family practice clinic. The proportion of subjects diagnosed with diabetic retinopathy and the quality of fundus images were compared. Among 872 patients (1,744 eyes) screened from rural sites and 517 subjects (1,034 eyes) screened from an urban site, images were of good quality for evaluation in 82.4% and 85.7% of subjects, respectively. Diabetic retinopathy was noted in 12.6% of rural subjects and 29.6% of urban subjects (p<0.001). nFP can be a useful tool in both rural and urban settings to screen for diabetic retinopathy in patients who are nonadherent to the recommended dilated annual eye exam. In our study population, a surprisingly higher percentage of diabetic subjects screened from the urban clinic had retinopathy compared with subjects screened in rural clinics.
Noopur, Gupta; Praveen, Vashist; Radhika, Tandon; Sanjeev K, Gupta; Mani, Kalaivani; Deepak, Kumar
2018-06-01
To assess awareness, barriers, and misconceptions related to eye donation in people with corneal disease as compared to controls in a population setting. A population-based study was conducted in 25 randomly selected clusters of Rural Gurgaon, Haryana, India, as part of the CORE (Cornea Opacity Rural Epidemiological) study. In addition to ophthalmic examination, knowledge and perceptions regarding eye donation were assessed through a validated questionnaire. The questionnaire captured the sociodemographic factors influencing awareness regarding eye donation in participants with corneal disease and twice the number of age- and gender-matched controls recruited from the same study clusters. Descriptive statistics were computed along with multivariable logistic regression analysis to determine associated factors for awareness of eye donation. In the CORE study, 452 participants had corneal opacities on ocular examination. Of these, 442 were assessed for eye donation awareness. Additionally, 884 age- and gender-matched controls were recruited. The mean age of cases and controls was 60.9 ± 15.5 and 59.6 ± 14.3 years, respectively. Awareness of eye donation in cases and controls was 46.4% (n = 205 of 442) and 52.3% (n = 462 of 884), respectively (P = 0.044). Educational status was an important factor determining knowledge about eye donation in both cases and controls (P = < 0.001). Major barriers reported for not pledging eyes were lack of willingness (36.7%) and ignorance (15.3%). Common misconceptions like eyes could be donated before death or even after 24 h of death and that any type of blindness could be treated with corneal transplantation were prevalent. The study demonstrated that although there is substantial awareness about eye donation, there are numerous barriers in this population that need to be resolved to improve donation rates. Additional efforts are needed to translate this awareness into actual eye donation in both cases with corneal disease and controls.
Djerada, Zoubir; Liang, Hong; El Sanharawi, Mohamed; Labbé, Antoine; Baudouin, Christophe
2017-01-01
Purpose To evaluate a possible clinical application of spectral-domain optical coherence tomography (SD-OCT) using en-face module for the imaging of the corneoscleral limbus in normal subjects and dry eye patients. Patients and methods Seventy-six subjects were included in this study. Seventy eyes of 35 consecutive patients with dry eye disease and 82 eyes of 41 healthy control subjects were investigated. All subjects were examined with the Avanti RTVue® anterior segment OCT. En-face OCT images of the corneoscleral limbus were acquired in four quadrants (inferior, superior, nasal and temporal) and then were analyzed semi-quantitatively according to whether or not palisades of Vogt (POV) were visible. En-face OCT images were then compared to in vivo confocal microscopy (IVCM) in eleven eyes of 7 healthy and dry eye patients. Results En-face SD-OCT showed POV as a radially oriented network, located in superficial corneoscleral limbus, with a good correlation with IVCM features. It provided an easy and reproducible identification of POV without any special preparation or any direct contact, with a grading scale from 0 (no visualization) to 3 (high visualization). The POV were found predominantly in superior (P<0.001) and inferior (P<0.001) quadrants when compared to the nasal and temporal quadrants for all subjects examined. The visibility score decreased with age (P<0.001) and was lower in dry eye patients (P<0.01). In addition, the score decreased in accordance with the severity of dry eye disease (P<0.001). Conclusion En-face SD-OCT is a non-contact imaging technique that can be used to evaluate the POV, thus providing valuable information about differences in the limbal anatomy of dry eye patients as compared to healthy patients. PMID:29176786
Prevalence and risk factors associated with work-related eye injuries in Bosnia and Herzegovina.
Jovanovic, Nina; Peek-Asa, Corinne; Swanton, Amanda; Young, Tracy; Alajbegovic-Halimic, Jasmina; Cavaljuga, Semra; Nisic, Faruk
2016-10-01
Eye injuries are a prevalent workplace injury and cause substantial disability when vision is impaired. To examine work-relatedness of demographic, injury, and clinical characteristics of eye injuries in a large clinic in Bosnia and Herzegovina. We performed a nine-year retrospective study of patients admitted with an eye injury to the Canton Hospital in Zenica, Bosnia and Herzeogvina. Controlling for age and sex, we used logistic regression to examine the influence of work-relatedness on patient and injury characteristics and clinical outcomes. Of 258 patients, 71 (27.5%) had work-related and 180 (69.8%) had non-work-related eye injuries. Work-related eye injury was associated with age, education, occupation, and injury type. Agricultural workers were eight times more likely to experience work-related eye injury (95%CI = 1.21-152.0) compared to manual workers. Work-relatedness of injury did not predict final visual acuity or length of hospital stay. Promotion of eye safety is needed countrywide. Occupational eye protection is a priority due to the relatively proportion of eye injuries and the workplace being a relatively controlled environment.
Khalifa, Mounir A.; Alsahn, Mahmoud F.; Shaheen, Mohamed Shafik; Pinero, David P.
2017-01-01
AIM To evaluate and compare the efficacy of the astigmatic correction achieved with laser in situ keratomileusis (LASIK) in eyes with myopic astigmatism using wavefront-guided (WFG) and wavefront-optimized (WFO) ablation profiles. METHODS Prospective study included 221 eyes undergoing LASIK: 99 and 122 eyes with low and moderate myopic astigmatism (low and moderate myopia groups). Two subgroups were differentiated in each group according to the ablation profile: WFG subgroup, 109 eyes (45/64, low/moderate myopia groups) treated using the Advanced CustomVue platform (Abbott Medical Optics Inc.), and WFO subgroup, 112 eyes (54/58, low/moderate myopia groups) treated using the EX-500 platform (Alcon). Clinical outcomes were evaluated during a 6-month follow-up, including a vector analysis of astigmatic changes. RESULTS Significantly better postoperative uncorrected visual acuity and efficacy index was found in the WFG subgroups of each group (P≤0.041). Postoperative spherical equivalent and cylinder were significantly higher in WFO subgroups (P≤0.003). In moderate myopia group, a higher percentage of eyes with a postoperative cylinder ≤0.25 D was found in the WFG subgroup (90.6% vs 65.5%, P=0.002). In low and moderate myopia groups, the difference vector was significantly higher in the WFO subgroup compared to WFG (P<0.001). In moderate myopia group, the magnitude (P=0.008) and angle of error (P<0.001) were also significantly higher in the WFO subgroup. Significantly less induction of high order aberrations were found with WFG treatments in both low and moderate myopia groups (P≤0.006). CONCLUSION A more efficacious correction of myopic astigmatism providing a better visual outcome is achieved with WFG LASIK compared to WFO LASIK. PMID:28251090
Cardiac autonomic denervation in Parkinson's disease is linked to REM sleep behavior disorder.
Postuma, Ronald B; Montplaisir, Jacques; Lanfranchi, Paola; Blais, Hélène; Rompré, Sylvie; Colombo, Roberto; Gagnon, Jean-François
2011-07-01
Recent studies have suggested a close connection between autonomic dysfunction and rapid eye movement sleep behavior disorder, which differs in nature from other early-stage markers of Parkinson's disease. In this study we examined the relationship between rapid eye movement sleep behavior disorder and autonomic dysfunction in Parkinson's disease as measured by cardiac beat-to-beat variability. In 53 patients with Parkinson's disease and 36 controls, electrocardiographic trace from a polysomnogram was assessed for measures of beat-to-beat RR variability including RR-standard deviation and frequency domains (low- and high-frequency components). Results were compared between patients with Parkinson's disease and controls, and between patients with Parkinson's disease with and without rapid eye movement sleep behavior disorder. On numerous cardiac autonomic measures, patients with Parkinson's disease showed clear abnormalities compared with controls. However, these abnormalities were confined only to those patients with associated rapid eye movement sleep behavior; those without were not different than controls. As with other clinical autonomic variables, cardiac autonomic denervation is predominantly associated not with Parkinson's disease itself, but with the presence of rapid eye movement sleep behavior disorder. Copyright © 2011 Movement Disorder Society.
The rate of endophthalmitis after pars plana vitrectomy and its risk factors.
Tabatabaei, Seyed Ali; Soleimani, Mohammad; Vakili, Hadi; Naderan, Morteza; Lashay, Alireza; Faghihi, Houshang; Yaseri, Mehdi
2018-05-11
To study the incidence of endophthalmitis after pars plana vitrectomy, its causative organisms, and visual acuity outcomes. In this retrospective, comparative study, the medical records of patients with acute-onset postoperative endophthalmitis after pars plana vitrectomy at Farabi Eye Hospital, Tehran, Iran, during a 12-year period between January 2004 and November 2015 were reviewed. To compare the endophthalmitis patients with other cases who underwent pars plana vitrectomy at the same day and also the same operating room, a control group was developed by gathering the data from surgical records. In the present study, the incidence rate of pos- vitrectomy endophthalmitis was 0.04% (16/39783). The organisms identified in aqueous or vitreous cultures (culture positive 44%) included Streptococcus pneumoniae (two patients, 12.5%), Pseudomonas aeruginosa (two patients, 12.5%), fungi (two patients, 12.5%), and Streptococcus viridans (one patient, 6.25%). Visual acuity after treatment for endophthalmitis ranged from light perception (7 eyes) to hand motion (1 eye), and evisceration was performed in 8 eyes (50%). When comparing the cases (patients developing endophthalmitis) and controls (patients with no complications operated in the same day and place of operation with the case group), only not using tamponade showed a statistically significant relation with the occurrence of endophthalmitis (p = 0.034). Our results indicated low incidence of endophthalmitis after pars plana vitrectomy comparable to previous studies which resulted in poor visual acuity. It seems that not using tamponade might increase the risk of endophthalmitis among these patients.
Hirata, Akimasa; Watanabe, Soichi; Taki, Masao; Fujiwara, Osamu; Kojima, Masami; Sasaki, Kazuyuki
2008-02-01
This study calculated the temperature elevation in the rabbit eye caused by 2.45-GHz near-field exposure systems. First, we calculated specific absorption rate distributions in the eye for different antennas and then compared them with those observed in previous studies. Next, we re-examined the temperature elevation in the rabbit eye due to a horizontally-polarized dipole antenna with a C-shaped director, which was used in a previous study. For our computational results, we found that decisive factors of the SAR distribution in the rabbit eye were the polarization of the electromagnetic wave and antenna aperture. Next, we quantified the eye average specific absorption rate as 67 W kg(-1) for the dipole antenna with an input power density at the eye surface of 150 mW cm(-2), which was specified in the previous work as the minimum cataractogenic power density. The effect of administrating anesthesia on the temperature elevation was 30% or so in the above case. Additionally, the position where maximum temperature in the lens appears is discussed due to different 2.45-GHz microwave systems. That position was found to appear around the posterior of the lens regardless of the exposure condition, which indicates that the original temperature distribution in the eye was the dominant factor.
Postanaesthetic tear production and ocular irritation in cats.
Peche, N; Köstlin, R; Reese, S; Pieper, K
2015-01-01
General anaesthesia significantly reduces tear production and normal values are not immediately re-established on ending anaesthesia. Therefore, adequate protection of the cornea has to be assured during the perianaesthetic period. There are various methods available, including taping of the eyelids and the application of eye ointments, gels and drops. In human medicine studies, different formulations were found to induce signs of ocular irritation. The aim of the present study was to determine tear production in cats after general anaesthesia, and to identify possible causes of irritation. Tear production was determined in 41 cats after general anaesthesia and eyes were examined for signs of irritation. Two different anaesthetic protocols were used. To protect the cornea, an ointment and gel were applied to the right and left eyes, respectively. Postoperatively, tear production was significantly reduced for 6 hours and 18 hours in the right and left eyes, respectively. Two hours after anaesthesia, blepharospasm of the right eye was observed in 92.7% (n = 38) of the cats. In contrast, the left eye was always held open. This study demonstrated that tear production in cats is significantly decreased both during and after anaesthesia. The degree of reduction was independent of the anaesthetic protocol. Both the eye ointment and gel proved effective in protecting the corneal surface. However, eye gel use is recommended because the eye ointment consistently caused an irritation comparable to the foreign-body sensation reported in humans.
Eye movement identification based on accumulated time feature
NASA Astrophysics Data System (ADS)
Guo, Baobao; Wu, Qiang; Sun, Jiande; Yan, Hua
2017-06-01
Eye movement is a new kind of feature for biometrical recognition, it has many advantages compared with other features such as fingerprint, face, and iris. It is not only a sort of static characteristics, but also a combination of brain activity and muscle behavior, which makes it effective to prevent spoofing attack. In addition, eye movements can be incorporated with faces, iris and other features recorded from the face region into multimode systems. In this paper, we do an exploring study on eye movement identification based on the eye movement datasets provided by Komogortsev et al. in 2011 with different classification methods. The time of saccade and fixation are extracted from the eye movement data as the eye movement features. Furthermore, the performance analysis was conducted on different classification methods such as the BP, RBF, ELMAN and SVM in order to provide a reference to the future research in this field.
Dexamethasone nanowafer as an effective therapy for dry eye disease.
Coursey, Terry G; Henriksson, Johanna Tukler; Marcano, Daniela C; Shin, Crystal S; Isenhart, Lucas C; Ahmed, Faheem; De Paiva, Cintia S; Pflugfelder, Stephen C; Acharya, Ghanashyam
2015-09-10
Dry eye disease is a major public health problem that affects millions of people worldwide. It is presently treated with artificial tear and anti-inflammatory eye drops that are generally administered several times a day and may have limited therapeutic efficacy. To improve convenience and efficacy, a dexamethasone (Dex) loaded nanowafer (Dex-NW) has been developed that can release the drug on the ocular surface for a longer duration of time than drops, during which it slowly dissolves. The Dex-NW was fabricated using carboxymethyl cellulose polymer and contains arrays of 500 nm square drug reservoirs filled with Dex. The in vivo efficacy of the Dex-NW was evaluated using an experimental mouse dry eye model. These studies demonstrated that once a day Dex-NW treatment on alternate days during a five-day treatment period was able to restore a healthy ocular surface and corneal barrier function with comparable efficacy to twice a day topically applied dexamethasone eye drop treatment. The Dex-NW was also very effective in down regulating expression of inflammatory cytokines (TNF-α, and IFN-γ), chemokines (CXCL-10 and CCL-5), and MMP-3, that are stimulated by dry eye. Despite less frequent dosing, the Dex-NW has comparable therapeutic efficacy to topically applied Dex eye drops in experimental mouse dry eye model, and these results provide a strong rationale for translation to human clinical trials for dry eye. Copyright © 2015 Elsevier B.V. All rights reserved.
Full 3-D OCT-based pseudophakic custom computer eye model
Sun, M.; Pérez-Merino, P.; Martinez-Enriquez, E.; Velasco-Ocana, M.; Marcos, S.
2016-01-01
We compared measured wave aberrations in pseudophakic eyes implanted with aspheric intraocular lenses (IOLs) with simulated aberrations from numerical ray tracing on customized computer eye models, built using quantitative 3-D OCT-based patient-specific ocular geometry. Experimental and simulated aberrations show high correlation (R = 0.93; p<0.0001) and similarity (RMS for high order aberrations discrepancies within 23.58%). This study shows that full OCT-based pseudophakic custom computer eye models allow understanding the relative contribution of optical geometrical and surgically-related factors to image quality, and are an excellent tool for characterizing and improving cataract surgery. PMID:27231608
Lee, Yung-Sung; See, Lai-Chu; Chang, Shu-Hao; Wang, Nan-Kai; Hwang, Yih-Shiou; Lai, Chi-Chun; Chen, Kuan-Jen; Wu, Wei-Chi
2018-05-10
To investigate the macular structures, optical components, and visual acuity in preschool-aged children with a history of type I retinopathy of prematurity who underwent either intravitreal bevacizumab (IVB), laser, or a combination of treatments. Comparative interventional case series. A referred medical center in Taiwan. 80 eyes from 42 patients (33 IVB-treated eyes from 17 children, 24 laser-treated eyes from 13 children, and 23 laser + IVB-treated eyes from 12 children). Spectral-domain optical coherence tomography. The retinal thickness in the foveal area and the associated morphologic changes in foveal depression. Compared with the laser-treated and laser + IVB-treated eyes, the IVB-treated eyes had less myopia and deeper anterior chamber depths but presented similar axial lengths and corneal curvatures (P = .001, .002, .95 and .16, respectively). The IVB-treated eyes had significantly thinner foveal, parafoveal, and perifoveal retinal thicknesses (P < .01 for all) and a higher incidence of foveal depression than the laser- or laser + IVB-treated eyes. The macular and subfoveal choroidal thicknesses did not differ among the groups (P = .21 and .63, respectively). Moreover, compared with the eyes treated with laser or laser + IVB, the IVB-treated eyes had better uncorrected visual acuity, although a significant difference was not observed in best-corrected visual acuity (P = .008 and .29, respectively). Compared with laser therapy, IVB-treated eyes were associated with deeper anterior chamber depths and thinner foveal, parafoveal and perifoveal thicknesses. Moreover, these IVB-treated eyes had less refractive errors and better uncorrected visual acuity. Copyright © 2018. Published by Elsevier Inc.
The effect of frontal air bags on eye injury patterns in automobile crashes.
Duma, Stefan M; Jernigan, M Virginia; Stitzel, Joel D; Herring, Ian P; Crowley, John S; Brozoski, Fred T; Bass, Cameron R
2002-11-01
To investigate eye injuries resulting from frontal automobile crashes and to determine the effects of frontal air bags. The National Automotive Sampling System database files from January 1, 1993, through December 31, 1999, were examined in a 3-part study that included an investigation of 22 236 individual crashes that occurred in the United States. A new 4-level eye injury severity scale that quantifies injuries based on recovery time, need for surgery, and possible loss of sight was developed. Of all occupants who were exposed to an air bag deployment, 3% sustained an eye injury. In contrast, 2% of occupants not exposed to an air bag deployment sustained an eye injury. A closer examination of the type of eye injuries showed that there was a statistically significant increase in the risk of corneal abrasions for occupants who were exposed to an air bag compared with those who were not (P =.03). Of occupants exposed to an air bag deployment, 0.5% sustained a corneal abrasion compared with 0.04% of occupants who were not exposed to an air bag. Using the new injury levels, it was shown that although occupants exposed to an air bag deployment had a higher risk of sustaining minor eye injuries, the air bag appears to have provided a beneficial exchange by reducing the number of severe eye injuries.
Retinotopic maps and foveal suppression in the visual cortex of amblyopic adults.
Conner, Ian P; Odom, J Vernon; Schwartz, Terry L; Mendola, Janine D
2007-08-15
Amblyopia is a developmental visual disorder associated with loss of monocular acuity and sensitivity as well as profound alterations in binocular integration. Abnormal connections in visual cortex are known to underlie this loss, but the extent to which these abnormalities are regionally or retinotopically specific has not been fully determined. This functional magnetic resonance imaging (fMRI) study compared the retinotopic maps in visual cortex produced by each individual eye in 19 adults (7 esotropic strabismics, 6 anisometropes and 6 controls). In our standard viewing condition, the non-tested eye viewed a dichoptic homogeneous mid-level grey stimulus, thereby permitting some degree of binocular interaction. Regions-of-interest analysis was performed for extrafoveal V1, extrafoveal V2 and the foveal representation at the occipital pole. In general, the blood oxygenation level-dependent (BOLD) signal was reduced for the amblyopic eye. At the occipital pole, population receptive fields were shifted to represent more parafoveal locations for the amblyopic eye, compared with the fellow eye, in some subjects. Interestingly, occluding the fellow eye caused an expanded foveal representation for the amblyopic eye in one early-onset strabismic subject with binocular suppression, indicating real-time cortical remapping. In addition, a few subjects actually showed increased activity in parietal and temporal cortex when viewing with the amblyopic eye. We conclude that, even in a heterogeneous population, abnormal early visual experience commonly leads to regionally specific cortical adaptations.
Karlsson, Petra; Wallen, Margaret
2017-01-01
Eye-gaze control technology enables people with significant physical disability to access computers for communication, play, learning and environmental control. This pilot study used a multiple case study design with repeated baseline assessment and parents' evaluations to compare two eye-gaze control technology systems to identify any differences in factors such as ease of use and impact of the systems for their young children. Five children, aged 3 to 5 years, with dyskinetic cerebral palsy, and their families participated. Overall, families were satisfied with both the Tobii PCEye Go and myGaze® eye tracker, found them easy to position and use, and children learned to operate them quickly. This technology provides young children with important opportunities for learning, play, leisure, and developing communication.
Chiang, Peggy P C; Zheng, Yingfeng; Wong, Tien Y; Lamoureux, Ecosse L
2013-02-01
To quantify the eye disease-specific impact of unilateral and bilateral vision impairment (VI) on vision-specific functioning (VF). The Singapore Indian Eye population-based study. Ethnic Indians older than 40 years of age living in Singapore. Participants underwent standardized ophthalmic assessments for VI and blindness, defined using presenting visual acuity (United States definition). Sociodemographic data were recorded using a standardized questionnaire. Rasch analysis was used to validate the Visual Function Index 11 and to determine its psychometric properties. The major causes of VI (i.e., cataract, refractive error, age-related macular degeneration, diabetic retinopathy [DR], and glaucoma) were determined by ophthalmologists on examination. Multivariate linear regression analysis was performed to assess the impact of VI on the overall VF Rasch score. Vision-specific functioning. Three thousand three hundred ninety-six persons were analyzed. Participants with VI had a systematic reduction in VF score compared with those with normal vision in both eyes, ranging from -11.2% normal vision in one eye and low vision in the other eye (95% confidence interval [CI], -12.2% to -10.3%; P<0.001), to -12.7% blindness in one eye and normal vision in the other eye (CI, -15.1% to -10.4%; P<0.001), to -19.4% low vision in both eyes (CI, -20.8% to -18.1%; P<0.001), to -52.9% blindness in one eye and low vision in other eye (CI, -55.3% to -50.4%; P<0.001), to -77.2% blindness in both eyes (CI, -82.4% to 72.0%; P<0.001). The impact of VI on VF score varied across different major causes of vision loss, regardless of socioeconomic factors. Vision impairment attributed to cataract in one or both eyes had a significant decrease in VF score by 17.7% and 22.3%, respectively, compared with those with normal vision in both eyes (P<0.001). The impact of unilateral and bilateral VI on VF score was greater in participants with glaucoma (32.2% in unilateral cases and 35.9% in bilateral cases; P<0.001) and DR (29.4% in unilateral cases and 33.3% in bilateral cases; P<0.001). Vision impairment and major age-related eye diseases such as cataract, DR, and glaucoma are associated significantly with worse deterioration in VF, regardless of education level, literacy adequacy, or immigration pattern. Glaucoma and DR seemed to have a greater negative impact on VF score compared with cataract. This study highlights the importance of disease-specific interventions in reducing the adverse impact of VI on daily activities. Copyright © 2013 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Isaacowitz, Derek M.; Livingstone, Kimberly M.; Harris, Julia A.; Marcotte, Stacy L.
2014-01-01
We report two studies representing the first use of mobile eye tracking to study emotion regulation across adulthood. Past research on age differences in attentional deployment using stationary eye tracking has found older adults show relatively more positive looking, and seem to benefit more mood-wise from this looking pattern, compared to younger adults. However, these past studies have greatly constrained the stimuli participants can look at, despite real-world settings providing numerous possibilities for what to choose to look at. We therefore used mobile eye tracking to study age differences in attentional selection, as indicated by fixation patterns to stimuli of different valence freely chosen by the participant. In contrast to stationary eye tracking studies of attentional deployment, Study 1 showed that younger and older individuals generally selected similar proportions of valenced stimuli, and attentional selection had similar effects on mood across age groups. Study 2 replicated this pattern with an adult lifespan sample including middle-aged individuals. Emotion regulation-relevant attention may thus differ depending on whether stimuli are freely chosen or not. PMID:25527965
Król, Magdalena Ewa
2018-01-01
We investigated the effect of auditory noise added to speech on patterns of looking at faces in 40 toddlers. We hypothesised that noise would increase the difficulty of processing speech, making children allocate more attention to the mouth of the speaker to gain visual speech cues from mouth movements. We also hypothesised that this shift would cause a decrease in fixation time to the eyes, potentially decreasing the ability to monitor gaze. We found that adding noise increased the number of fixations to the mouth area, at the price of a decreased number of fixations to the eyes. Thus, to our knowledge, this is the first study demonstrating a mouth-eyes trade-off between attention allocated to social cues coming from the eyes and linguistic cues coming from the mouth. We also found that children with higher word recognition proficiency and higher average pupil response had an increased likelihood of fixating the mouth, compared to the eyes and the rest of the screen, indicating stronger motivation to decode the speech.
2018-01-01
We investigated the effect of auditory noise added to speech on patterns of looking at faces in 40 toddlers. We hypothesised that noise would increase the difficulty of processing speech, making children allocate more attention to the mouth of the speaker to gain visual speech cues from mouth movements. We also hypothesised that this shift would cause a decrease in fixation time to the eyes, potentially decreasing the ability to monitor gaze. We found that adding noise increased the number of fixations to the mouth area, at the price of a decreased number of fixations to the eyes. Thus, to our knowledge, this is the first study demonstrating a mouth-eyes trade-off between attention allocated to social cues coming from the eyes and linguistic cues coming from the mouth. We also found that children with higher word recognition proficiency and higher average pupil response had an increased likelihood of fixating the mouth, compared to the eyes and the rest of the screen, indicating stronger motivation to decode the speech. PMID:29558514
Retinal cell imaging in myopic chickens using adaptive optics multiphoton microscopy.
Bueno, Juan M; Palacios, Raquel; Giakoumaki, Anastasia; Gualda, Emilio J; Schaeffel, Frank; Artal, Pablo
2014-03-01
Abnormal eye growth induced by visual deprivation can modify the structure and density of the retinal cells. We have used an adaptive optics multiphoton microscope to image photoreceptors (PRs) and ganglion cells (GCs) at different retinal locations in unstained retinas of chicken eyes with about 10D of myopia and their normal-sighted fellow eyes. In all samples, the local averaged inter-PR distance increased with eccentricity. No significant differences in PR density were found between control and myopic eyes. GC density declined in myopic eyes compared to control eyes and the inter-cell distance increased. In normal eyes, the size of the GC cell bodies increased approximately two-fold between the area centralis and the peripheral retina. In myopic eyes, this trend was preserved but the GC bodies were larger at each retinal location, compared to control eyes. Obviously, GC morphology is changing when the retinal area is enlarged in myopic eyes.
Retinal cell imaging in myopic chickens using adaptive optics multiphoton microscopy
Bueno, Juan M.; Palacios, Raquel; Giakoumaki, Anastasia; Gualda, Emilio J.; Schaeffel, Frank; Artal, Pablo
2014-01-01
Abnormal eye growth induced by visual deprivation can modify the structure and density of the retinal cells. We have used an adaptive optics multiphoton microscope to image photoreceptors (PRs) and ganglion cells (GCs) at different retinal locations in unstained retinas of chicken eyes with about 10D of myopia and their normal-sighted fellow eyes. In all samples, the local averaged inter-PR distance increased with eccentricity. No significant differences in PR density were found between control and myopic eyes. GC density declined in myopic eyes compared to control eyes and the inter-cell distance increased. In normal eyes, the size of the GC cell bodies increased approximately two-fold between the area centralis and the peripheral retina. In myopic eyes, this trend was preserved but the GC bodies were larger at each retinal location, compared to control eyes. Obviously, GC morphology is changing when the retinal area is enlarged in myopic eyes. PMID:24688804
Moro, Stefania S; Steeves, Jennifer K E
2018-04-13
Previously, we have shown that people who have had one eye surgically removed early in life during visual development have enhanced sound localization [1] and lack visual dominance, commonly observed in binocular and monocular (eye-patched) viewing controls [2]. Despite these changes, people with one eye integrate auditory and visual components of multisensory events optimally [3]. The current study investigates how people with one eye perceive the McGurk effect, an audiovisual illusion where a new syllable is perceived when visual lip movements do not match the corresponding sound [4]. We compared individuals with one eye to binocular and monocular viewing controls and found that they have a significantly smaller McGurk effect compared to binocular controls. Additionally, monocular controls tended to perceive the McGurk effect less often than binocular controls suggesting a small transient modulation of the McGurk effect. These results suggest altered weighting of the auditory and visual modalities with both short and long-term monocular viewing. These results indicate the presence of permanent adaptive perceptual accommodations in people who have lost one eye early in life that may serve to mitigate the loss of binocularity during early brain development. Crown Copyright © 2018. Published by Elsevier B.V. All rights reserved.
Active eye-tracking improves LASIK results.
Lee, Yuan-Chieh
2007-06-01
To study the advantage of active eye-tracking for photorefractive surgery. In a prospective, double-masked study, LASIK for myopia and myopic astigmatism was performed in 50 patients using the ALLEGRETTO WAVE version 1007. All patients received LASIK with full comprehension of the importance of fixation during the procedure. All surgical procedures were performed by a single surgeon. The eye-tracker was turned off in one group (n = 25) and kept on in another group (n = 25). Preoperatively and 3 months postoperatively, patients underwent a standard ophthalmic examination, which included comeal topography. In the patients treated with the eye-tracker off, all had uncorrected visual acuity (UCVA) of > or = 20/40 and 64% had > or = 20/20. Compared with the patients treated with the eye-tracker on, they had higher residual cylindrical astigmatism (P < .05). Those treated with the eye-tracker on achieved better UCVA and best spectacle-corrected visual acuity (P < .05). Spherical error and potential visual acuity (TMS-II) were not significantly different between the groups. The flying-spot system can achieve a fair result without active eye-tracking, but active eye-tracking helps improve the visual outcome and reduces postoperative cylindrical astigmatism.
Eye-closure-triggered paroxysmal activity and cognitive impairment: a case report.
Termine, Cristiano; Rubboli, Guido; Veggiotti, Pierangelo
2006-01-01
To study the neuropsychological status of an epileptic patient presenting with epileptic activity triggered by eye closure in a 14-year follow-up period. The patient was studied at 12 and 26 years of age; during this period he underwent periodical clinical evaluations and EEG investigations; brain magnetic resonance imaging (MRI) was performed at 12 years of age. A neuropsychological assessment was carried out both at 12 years of age (T0) and at 26 years of age. At T0 and T1, neuropsychological tests (digits and words span, graphoestesia, reactions time to auditory stimuli, sentences repetition, words repetition, digital gnosis, backward counting [i.e.,100-0]) were performed during video-EEG monitoring either with eyes closed or with eyes open, to evaluate possible transitory effects related to ongoing epileptic activity. Moreover, at T0 the patient underwent Wechsler Intelligence Scale for Children-Revised, and at T1 to Wechsler Adult Intelligence Scale-Revised. EEG recordings showed continuous epileptic activity triggered by eye closure, disappearing only with eyes opening, both at T0 and T1 (in this latter case, anteriorly predominant). The results of neuropsychological assessment during eyes closed as compared to performances with eyes open did not show significant differences, at T0 as well as at T1. Wechsler Intelligence scales showed a deterioration of performances at T1 with respect to T0; in addition, at T1, attention and short-term memory abnormalities, impairment in facial recognition and block design, and defective results in Continuous Performance Test and Wisconsin Card Sorting Test were observed. Lack of differences between the results of neuropsychological tests performed with eyes closed as compared to the eyes open condition suggests that in our patient epileptic activity did not cause transitory cognitive abnormalities. Deterioration of Wechsler Intelligence Scales in the follow-up period might be interpreted as the result of a disruption of cognitive processes possibly related to the persistence of a continuous epileptic activity during eye closure over the years. We speculate whether a dysfunction in posterior cortical areas involved in visual processing might be related to the impairment in face recognition and block design tests as well to eye closure sensitivity.
Hutson, John P; Smith, Tim J; Magliano, Joseph P; Loschky, Lester C
2017-01-01
Film is ubiquitous, but the processes that guide viewers' attention while viewing film narratives are poorly understood. In fact, many film theorists and practitioners disagree on whether the film stimulus (bottom-up) or the viewer (top-down) is more important in determining how we watch movies. Reading research has shown a strong connection between eye movements and comprehension, and scene perception studies have shown strong effects of viewing tasks on eye movements, but such idiosyncratic top-down control of gaze in film would be anathema to the universal control mainstream filmmakers typically aim for. Thus, in two experiments we tested whether the eye movements and comprehension relationship similarly held in a classic film example, the famous opening scene of Orson Welles' Touch of Evil (Welles & Zugsmith, Touch of Evil, 1958). Comprehension differences were compared with more volitionally controlled task-based effects on eye movements. To investigate the effects of comprehension on eye movements during film viewing, we manipulated viewers' comprehension by starting participants at different points in a film, and then tracked their eyes. Overall, the manipulation created large differences in comprehension, but only produced modest differences in eye movements. To amplify top-down effects on eye movements, a task manipulation was designed to prioritize peripheral scene features: a map task. This task manipulation created large differences in eye movements when compared to participants freely viewing the clip for comprehension. Thus, to allow for strong, volitional top-down control of eye movements in film, task manipulations need to make features that are important to narrative comprehension irrelevant to the viewing task. The evidence provided by this experimental case study suggests that filmmakers' belief in their ability to create systematic gaze behavior across viewers is confirmed, but that this does not indicate universally similar comprehension of the film narrative.
Eye Movement Indices in the Study of Depressive Disorder
LI, Yu; XU, Yangyang; XIA, Mengqing; ZHANG, Tianhong; WANG, Junjie; LIU, Xu; HE, Yongguang; WANG, Jijun
2016-01-01
Background Impaired cognition is one of the most common core symptoms of depressive disorder. Eye movement testing mainly reflects patients’ cognitive functions, such as cognition, memory, attention, recognition, and recall. This type of testing has great potential to improve theories related to cognitive functioning in depressive episodes as well as potential in its clinical application. Aims This study investigated whether eye movement indices of patients with unmedicated depressive disorder were abnormal or not, as well as the relationship between these indices and mental symptoms. Methods Sixty patients with depressive disorder and sixty healthy controls (who were matched by gender, age and years of education) were recruited, and completed eye movement tests including three tasks: fixation task, saccade task and free-view task. The EyeLink desktop eye tracking system was employed to collect eye movement information, and analyze the eye movement indices of the three tasks between the two groups. Results (1) In the fixation task, compared to healthy controls, patients with depressive disorder showed more fixations, shorter fixation durations, more saccades and longer saccadic lengths; (2) In the saccade task, patients with depressive disorder showed longer anti-saccade latencies and smaller anti-saccade peak velocities; (3) In the free-view task, patients with depressive disorder showed fewer saccades and longer mean fixation durations; (4) Correlation analysis showed that there was a negative correlation between the pro-saccade amplitude and anxiety symptoms, and a positive correlation between the anti-saccade latency and anxiety symptoms. The depression symptoms were negatively correlated with fixation times, saccades, and saccadic paths respectively in the free-view task; while the mean fixation duration and depression symptoms showed a positive correlation. Conclusion Compared to healthy controls, patients with depressive disorder showed significantly abnormal eye movement indices. In addition patients’ anxiety and depression symptoms and eye movement indices were correlated. The pathological meaning of these phenomena deserve further exploration. PMID:28638208
Eye Movement Indices in the Study of Depressive Disorder.
Li, Yu; Xu, Yangyang; Xia, Mengqing; Zhang, Tianhong; Wang, Junjie; Liu, Xu; He, Yongguang; Wang, Jijun
2016-12-25
Impaired cognition is one of the most common core symptoms of depressive disorder. Eye movement testing mainly reflects patients' cognitive functions, such as cognition, memory, attention, recognition, and recall. This type of testing has great potential to improve theories related to cognitive functioning in depressive episodes as well as potential in its clinical application. This study investigated whether eye movement indices of patients with unmedicated depressive disorder were abnormal or not, as well as the relationship between these indices and mental symptoms. Sixty patients with depressive disorder and sixty healthy controls (who were matched by gender, age and years of education) were recruited, and completed eye movement tests including three tasks: fixation task, saccade task and free-view task. The EyeLink desktop eye tracking system was employed to collect eye movement information, and analyze the eye movement indices of the three tasks between the two groups. (1) In the fixation task, compared to healthy controls, patients with depressive disorder showed more fixations, shorter fixation durations, more saccades and longer saccadic lengths; (2) In the saccade task, patients with depressive disorder showed longer anti-saccade latencies and smaller anti-saccade peak velocities; (3) In the free-view task, patients with depressive disorder showed fewer saccades and longer mean fixation durations; (4) Correlation analysis showed that there was a negative correlation between the pro-saccade amplitude and anxiety symptoms, and a positive correlation between the anti-saccade latency and anxiety symptoms. The depression symptoms were negatively correlated with fixation times, saccades, and saccadic paths respectively in the free-view task; while the mean fixation duration and depression symptoms showed a positive correlation. Compared to healthy controls, patients with depressive disorder showed significantly abnormal eye movement indices. In addition patients' anxiety and depression symptoms and eye movement indices were correlated. The pathological meaning of these phenomena deserve further exploration.
Effect of iris registration on outcomes of FEMTOLASIK for myopia and myopic astigmatism.
Ghoreishi, Mohammad; Beni, Zahra Naderi; Beni, Afsaneh Naderi; Kianersi, Farzan
2017-09-05
To compare the visual and refractive outcomes after FEMTOLASIK with and without iris registration. In this randomized, prospective, comparative, contralateral eye study, 118 eyes of 59 patients with myopia and myopic astigmatism underwent LASIK using the Femto LDV femtosecond laser (160 µm) and the MEL80 with or without iris registration. For each patient, iris registration FEMTOLASIK was performed on one eye and non-iris registration FEMTOLASIK was performed on the other eye, assigned at random. Patients were evaluated before and 12 months. Uncorrected visual acuity, best-corrected visual acuity, manifest refraction, contrast sensitivity, and higher-order aberrations (HOAs) were evaluated. At 12 months, the mean UDVA was 0.002 ± 0.07 logMAR (20/19) in iris registration eyes and 0.00 ± 0.06 logMAR (20/24) in non-iris registration eyes (P = 0.9). 61% of iris registration eyes and 71.2% of non-iris registration eyes achieved a UDVA of 20/20 or better (P = 0.31); 98.3% of eyes with the iris registration FEMTOLASIK and 94.9% with the non-iris registration FEMTOLASIK were within ±0.50 D from emmetropia (P = 0.71). No statistically significant difference was found in postoperative contrast sensitivity between groups at 3, 6, 12, or 18 cycles/degree (P > 0.05). There was significant increase in total HOA root mean square in two groups. The mean error magnitude of surgically induced astigmatism 12 months postoperatively was -0.33 in iris registration eyes and -0.24 in the non-iris registration eyes (P = 0.36). FEMTOLASIK with and without iris registration provides similar results in myopic and myopic astigmatism patients.
Discordant Dry Eye Disease (An American Ophthalmological Society Thesis)
Shtein, Roni M.; Harper, Daniel E.; Pallazola, Vincent; Harte, Steven E.; Hussain, Munira; Sugar, Alan; Williams, David A.; Clauw, Daniel J.
2016-01-01
Purpose To improve understanding of dry eye disease and highlight a subgroup of patients who have a component of central sensitization and neuropathic pain contributing to their condition. Methods Prospective, cross-sectional, IRB-approved study comparing isolated dry eye disease (n=48) to fibromyalgia (positive control; n=23) and healthy (negative control; n=26) individuals with ocular surface examination, corneal confocal microscopy, quantitative sensory testing, and self-reported ocular symptoms and systemic associations. A subset of patients also underwent skin biopsy and/or brain neuroimaging. Dry eye patients were split into concordant (ie, those with dry eyes on examination) and discordant (ie, those with dry eye symptoms but normal examination) subgroups for further analysis. We hypothesized that on the systemic measures included, concordant patients would resemble healthy controls, whereas discordant patients would show evidence of centralized mechanisms similar to fibromyalgia. Results Schirmer test and Ocular Surface Disease Index (OSDI) scores indicated significant decreases in tear production (Schirmer: healthy, 18.5±8.2 mm; dry, 11.2±5.4 mm; fibromyalgia, 14.4±7.5; P<.001) and increases in self-reported dry eye symptoms (OSDI: healthy, 1.9±3.0; dry, 20.3±17.7; fibromyalgia, 20.3±17.1; P<.001) in the dry eye and fibromyalgia patients, compared to controls. The discordant subgroup had decreased corneal nerve density and decreased visual quality-of-life scores, similar to patients with fibromyalgia. Concordant patients were more similar to healthy controls on these measures. Conclusions Individuals with discordant dry eye may have a central pathophysiologic mechanism leading to their eye pain symptoms, which could be an important factor to consider in treatment of chronic idiopathic dry eye. PMID:28050051
Discordant Dry Eye Disease (An American Ophthalmological Society Thesis).
Shtein, Roni M; Harper, Daniel E; Pallazola, Vincent; Harte, Steven E; Hussain, Munira; Sugar, Alan; Williams, David A; Clauw, Daniel J
2016-08-01
To improve understanding of dry eye disease and highlight a subgroup of patients who have a component of central sensitization and neuropathic pain contributing to their condition. Prospective, cross-sectional, IRB-approved study comparing isolated dry eye disease (n=48) to fibromyalgia (positive control; n=23) and healthy (negative control; n=26) individuals with ocular surface examination, corneal confocal microscopy, quantitative sensory testing, and self-reported ocular symptoms and systemic associations. A subset of patients also underwent skin biopsy and/or brain neuroimaging. Dry eye patients were split into concordant (ie, those with dry eyes on examination) and discordant (ie, those with dry eye symptoms but normal examination) subgroups for further analysis. We hypothesized that on the systemic measures included, concordant patients would resemble healthy controls, whereas discordant patients would show evidence of centralized mechanisms similar to fibromyalgia. Schirmer test and Ocular Surface Disease Index (OSDI) scores indicated significant decreases in tear production (Schirmer: healthy, 18.5±8.2 mm; dry, 11.2±5.4 mm; fibromyalgia, 14.4±7.5; P <.001) and increases in self-reported dry eye symptoms (OSDI: healthy, 1.9±3.0; dry, 20.3±17.7; fibromyalgia, 20.3±17.1; P <.001) in the dry eye and fibromyalgia patients, compared to controls. The discordant subgroup had decreased corneal nerve density and decreased visual quality-of-life scores, similar to patients with fibromyalgia. Concordant patients were more similar to healthy controls on these measures. Individuals with discordant dry eye may have a central pathophysiologic mechanism leading to their eye pain symptoms, which could be an important factor to consider in treatment of chronic idiopathic dry eye.
Perera, Shamira A; Quek, Desmond T; Baskaran, Mani; Tun, Tin A; Kumar, Rajesh S; Friedman, David S; Aung, Tin
2010-06-01
To evaluate EyeCam in detecting changes in angle configuration after laser peripheral iridotomy (LPI) in comparison to gonioscopy, the reference standard. Prospective comparative study. Twenty-four subjects (24 eyes) with primary angle-closure glaucoma (PACG) were recruited. Gonioscopy and EyeCam (Clarity Medical Systems) imaging of all 4 angle quadrants were performed, before and 2 weeks after LPI. Images were graded according to angle structures visible by an observer masked to clinical data or the status of LPI, and were performed in a random order. Angle closure in a quadrant was defined as the inability to visualize the posterior trabecular meshwork. We determined the number of quadrants with closed angles and the mean number of clock hours of angle closure before and after LPI in comparison to gonioscopy. Using EyeCam, all 24 eyes showed at least 1 quadrant of angle widening after LPI. The mean number of clock hours of angle closure decreased significantly, from 8.15 +/- 3.47 clock hours before LPI to 1.75 +/- 2.27 clock hours after LPI (P < .0001, Wilcoxon signed rank test). Overall, gonioscopy showed 1.0 +/- 1.41 (95% CI, 0.43-1.57) quadrants opening from closed to open after LPI compared to 2.0 +/- 1.28 (95% CI, 1.49-2.51, P = .009) quadrants with EyeCam. Intra-observer reproducibility of grading the extent of angle closure in clock hours in EyeCam images was moderate to good (intraclass correlation coefficient 0.831). EyeCam may be used to document changes in angle configuration after LPI in eyes with PACG. Copyright 2010 Elsevier Inc. All rights reserved.
Mello-Bosnic, Claudia; Gimenes, Alexandre Dantas; Oliani, Sonia Maria; Gil, Cristiane Damas
2018-05-31
Galectin-1 (Gal-1) is a β-galactoside-binding protein with diverse biological activities in the pathogenesis of inflammation, however the mechanisms by which Gal-1 modulates cellular responses in allergic inflammatory processes have not been fully determined. In this study, we evaluated the therapeutic potential of Gal-1 eye drops in an experimental model of conjunctivitis. Wistar rats received a topical application of compound (C)48/80 (100 mg/ml) into right eyes and a drop of vehicle into the contralateral eye. Another group of rats received Gal-1 (0.3 or 3 μg/eye) or sodium cromoglycate (SCG; 40 mg/ml) in both eyes and, after 15 min, right eye was challenged with C48/80. Conjunctivitis-induced by C48/80 was characterized by severe eyelid oedema and tearing, but clinical signs were ameliorated by eye drop doses of both Gal-1 (0.3/3 μg) and SCG. As expected, an increased proportion of degranulated mast cells (62%, P < 0.01) and lower histamine levels were observed after 6 h of C48/80 challenge, compared to control (32%). This effect was abrogated by Gal-1 and SCG, which reduced mast cell degranulation (31-36%), eosinophil migration and eosinophil peroxidase levels in the eyes. Gal-1 (3 μg) and SCG treatments also decreased IL-4 levels, as well as activation of mitogen activated protein kinases compared to untreated C48/80 eyes. Our findings suggest that Gal-1 eye drops represent a new therapeutic strategy for ocular allergic inflammation. Copyright © 2018 Elsevier B.V. All rights reserved.
Sia, Rose K; Ryan, Denise S; Edwards, Jayson D; Stutzman, Richard D; Bower, Kraig S
2014-04-01
To compare visual outcomes following photorefractive keratectomy (PRK), PRK with mitomycin C (MMC-PRK), and LASEK in moderate and high myopia in military personnel. This prospective, randomized contralateral eye study included 167 patients 21 years or older with manifest spherical equivalent -5.99 ± 1.40 diopters (D) (range: -3.88 to -9.38 D) randomized to either MMC-PRK or LASEK treatment in their dominant eye and conventional PRK without MMC in the fellow eye. All procedures were performed using the LADARVision 4000 Excimer Laser System (Alcon Surgical Inc., Ft. Worth, TX). High- and low-contrast visual acuities, manifest refraction, endothelial cell count, and corneal haze were evaluated up to 12 months postoperatively. At 12 months postoperatively, visual outcomes were comparable among the treatment groups. Corneal haze of any grade was less common in MMC-PRK compared to PRK at 1 month (21.4% vs 31.0%; P < .01) and 3 months (12.8% vs 35.9%; P = .03) postoperatively; it was also less common in MMC-PRK compared to LASEK at 1 month (21.4% vs 55.9%; P < .01), 3 months (12.8% vs 42.4%; P < .01), and 6 months (12.2% vs 36.4%; P = .03) postoperatively. Haze rate (grade 0.5 or higher) was comparable between LASEK and PRK. Clinically significant haze (grade 2 or higher) developed after PRK (4 eyes) and LASEK (2 eyes), but not after MMC-PRK. MMC-PRK showed some benefits in minimizing corneal haze formation. One year after surgery, there was no discernible difference in the postoperative refractive outcomes among the three methods. Copyright 2014, SLACK Incorporated.
Hsu, S L; Lee, P Y; Chang, C H; Chen, C H
2016-08-30
Thyroid orbitopathy (TO) is an autoimmune disease that is complicated by ocular surface disorders, leading to discomfort. Dry eye is very prevalent in patients with TO. Recent studies on the pathogenesis of dry eye have focused on the inflammatory process, and some supporting evidence has been discovered. Because TO is a disorder of autoimmune origin, we assumed that the association between TO and dry eye is related to inflammation. Inflammation of the ocular surface in TO-related dry eye has not been well studied. In this study, we assessed cellular inflammation of the ocular surface and the cytokine profiles in patients with TO-related dry eye. Conjunctival impression cytology (CIC) was assessed with an immunofluorescent assay. TO-related dry eye was diagnosed by using the Schirmer test, tear break-up time, thyroid function, and clinical signs. CIC was combined with immunological staining of interleukin-1a (IL-1a), IL-1b, and IL- 6. The immunological impression cytology (IC) grade was compared to the clinical activity score of TO. All TO patients with dry eye were positive for IL-1a, IL-1b, and IL-6. However, the normal controls were also positive for IL-1a. A trend was observed between the clinical inflammatory score and immunological IC grade. This study was the first to delineate the immunological IC of TO-related dry eye. Our study aimed to investigate the pathogenesis of dry eye in TO. Our findings suggest that the conjunctival cytokines IL-1a, IL-1b, and IL-6 may play a role. The results of this study will be useful for future studies of additional inflammatory cytokines, and the levels of these cytokines could be used as an outcome to assess the efficacy of treatment, such as anti-cytokine or immunosuppression therapy, in patients with TO-related dry eye or other ocular surface inflammatory disorders.
NASA Astrophysics Data System (ADS)
Zhang, Mei; Wang, Zhao-Qi; Wang, Yan; Zuo, Tong
2010-10-01
The aim of this research is to study the properties of the transverse chromatic aberration (TCA) after the LASIK refractive surgery based on the individual eye model involving the angle between visual axis and optical axis. According to the measurements of the corneal surfaces, the optical axis lengths and the wavefront aberrations, the individual eye models before and after LASIK refractive surgery are constructed for 15 eyes by using ZEMAX optic design software, while the angle between the visual axis and optical axis is calculated from the data of the anterior corneal surface. The constructed eye models are then used to investigate the variation of the TCA after the surgery. The statistical distributions of the magnitude of the foveal TCA for 15 eyes over the visible spectrum are provided. Finally, we investigate the influence of the TCA on the visual quality and compare the results with previous research. The TCA is an indispensable criterion to evaluate the performance of the refractive surgery. This research is very meaningful for the studies of not only foveal vision but also the peripheral vision.
[Age factor in eye regeneration of the gastropod mollusk Achatina fulica].
Tartakovskaia, O S; Borisenko, S L; Zhukov, V V
2003-01-01
The dependence of the ability to regenerate the eye on the age of experimental animals was studied in the snail Achatina fulica. The degree of regeneration was estimated by light-microscopic and electrophysiological methods and by analyzing the motor response to visual stimuli. In older age groups, the number of regenerated eye-bearing tentacles decreased, whereas the period of regeneration increased. The regenerated eyes of the snails operated at the age of more than two months remained smaller than normal eyes even after six months. Regeneration of the distal part of the optic nerve was observed, and the regenerated eyes recovered the ability to respond to stimulation by light. In the electroretinogram, the responses of the regenerated eye, compared to the control, were characterised by a lower amplitude and longer repolarization and refractory periods. Manifestations of the motor response to visual stimuli in the young snails with regenerating eyes could be regarded as evidence for the recovery of connection between the organ of sight and the central ganglia.
NASA Astrophysics Data System (ADS)
Tornow, Ralf P.; Milczarek, Aleksandra; Odstrcilik, Jan; Kolar, Radim
2017-07-01
A parallel video ophthalmoscope was developed to acquire short video sequences (25 fps, 250 frames) of both eyes simultaneously with exact synchronization. Video sequences were registered off-line to compensate for eye movements. From registered video sequences dynamic parameters like cardiac cycle induced reflection changes and eye movements can be calculated and compared between eyes.
Analysis of corneal astigmatism before surgery in Chinese congenital ectopia lentis patients.
Zhang, Yichi; Jin, Guangming; Young, Charlotte Aimee; Cao, Qianzhong; Lin, Junxiong; Lin, Jianqiang; Wang, Yiyao; Zheng, Danying
2018-04-26
Purpose This study aims to describe the characteristics of corneal astigmatism before surgery in congenital ectopia lentis (CEL) patients. Methods This retrospective study reviewed 306 CEL patients from 1st January 2006, to 31st December 2015. One eye was randomly selected from each patient when the patient had bilateral EL. The influence of sex, laterality, and Marfan syndrome on corneal astigmatism in different age subgroups was evaluated and compared. The correlation between age and corneal astigmatism was evaluated. Results Two hundred fifty-two eyes were included in this study. The mean corneal astigmatism of CEL patients was 2.00 ± 1.28 D. There was a statistical difference in corneal astigmatism between CEL eyes with and without Marfan syndrome. However, no statistical difference was found between male and female patients, or between the EL-affected eye and the unaffected eye in monocular EL patients. There was a positive correlation between age and corneal astigmatism in CEL eyes. Conclusions This study suggests that CEL patients' corneal astigmatism is higher in patients with Marfan syndrome, and corneal astigmatism of the CEL eye increases with age. Our results are useful for surgeons to make appropriate incision and intraocular lens (IOL) choices for patients, as well as a useful reference for designs of new IOLs.
An optomechanical model eye for ophthalmological refractive studies.
Arianpour, Ashkan; Tremblay, Eric J; Stamenov, Igor; Ford, Joseph E; Schanzlin, David J; Lo, Yuhwa
2013-02-01
To create an accurate, low-cost optomechanical model eye for investigation of refractive errors in clinical and basic research studies. An optomechanical fluid-filled eye model with dimensions consistent with the human eye was designed and fabricated. Optical simulations were performed on the optomechanical eye model, and the quantified resolution and refractive errors were compared with the widely used Navarro eye model using the ray-tracing software ZEMAX (Radiant Zemax, Redmond, WA). The resolution of the physical optomechanical eye model was then quantified with a complementary metal-oxide semiconductor imager using the image resolution software SFR Plus (Imatest, Boulder, CO). Refractive, manufacturing, and assembling errors were also assessed. A refractive intraocular lens (IOL) and a diffractive IOL were added to the optomechanical eye model for tests and analyses of a 1951 U.S. Air Force target chart. Resolution and aberrations of the optomechanical eye model and the Navarro eye model were qualitatively similar in ZEMAX simulations. Experimental testing found that the optomechanical eye model reproduced properties pertinent to human eyes, including resolution better than 20/20 visual acuity and a decrease in resolution as the field of view increased in size. The IOLs were also integrated into the optomechanical eye model to image objects at distances of 15, 10, and 3 feet, and they indicated a resolution of 22.8 cycles per degree at 15 feet. A life-sized optomechanical eye model with the flexibility to be patient-specific was designed and constructed. The model had the resolution of a healthy human eye and recreated normal refractive errors. This model may be useful in the evaluation of IOLs for cataract surgery. Copyright 2013, SLACK Incorporated.
A comparison of basal and eye-flush tears for the analysis of cat tear proteins.
Petznick, Andrea; Evans, Margaret D M; Madigan, Michele C; Markoulli, Maria; Garrett, Qian; Sweeney, Deborah F
2011-02-01
To identify a rapid and effective tear collection method providing sufficient tear volume and total protein content (TPC) for analysis of individual proteins in cats. Domestic adult short-haired cats (12-37 months; 2.7-6.6 kg) were used in the study. Basal tears without stimulation and eye-flush tears after instillation of saline (10 μl) were collected using microcapillary tubes from animal eyes either unwounded control or wounded with 9-mm central epithelial debridement giving four groups with n = 3. Tear comparisons were based on total time and rate for tear collection, TPC using micro bicinchoninic acid (BCA), tear immunoglobulin A (IgA), total matrix-metalloproteinase (MMP)-9 concentration using sandwich enzyme-linked immunosorbent assay (ELISA) and MMP-9 activity. Eye-flush tears were collected significantly faster than basal tears in wounded eyes with higher rates for tear collection in unwounded control and wounded eyes. TPC was significantly lower in eye-flush tears compared to basal tears. The relative proportion of tear IgA normalized to TPC (% IgA of TPC) was not significantly different between basal and eye-flush tears. In unwounded control eyes, MMP-9 was slightly higher in eye-flush than in basal tears; activity of MMP-9 in both tear types was similar. In wounded eyes, eye-flush tears showed highest MMP-9 levels and activity on Day 1, which subsequently decreased to Day 7. MMP-9 activity in basal tears from wounded eyes did not display changes in expression. Eye-flush tears can be collected rapidly providing sufficient tear volume and TPC. This study also indicates that eye-flush tears may be more suitable than basal tears for the analysis of MMPs following corneal wounding. © 2011 The Authors. Acta Ophthalmologica © 2011 Acta Ophthalmologica Scandinavica Foundation.
Huseyinoglu, Nergiz; Ekinci, Metin; Ozben, Serkan; Buyukuysal, Cagatay
2014-01-01
Abstract Studies that explored the anterior visual pathway in the patients with multiple sclerosis (MS) have demonstrated contradictory results about the correlation between structural and functional status of optic nerve and retina. We aimed to investigate the functional and structural findings in our cohort of mildly disabled relapsing-remitting MS patients. A total of 134 eyes (80 eyes of the patients with MS and 54 eyes of the control group) were investigated. Eyes of MS patients were divided into two groups—as eyes with history of optic neuritis (ON group) and without history of optic neuritis (NON group). Ophthalmological investigation including visual evoked potentials, standard automated perimetry, and optical coherence tomography were performed for all participants. Retinal and macular thicknesses were significantly decreased in ON and NON groups compared with controls. Also, visual evoked potential latencies and visual field loss were worse in the both MS groups compared with control group. We did not find any correlation between visual evoked potentials and retinal or macular thickness values but visual field parameters were correlated between retinal and macular layer loss in the NON group. According to our results and some previous studies, although both functional and structural changes were detected in patients with MS, functional status markers do not always show parallelism (or synchrony) with structural changes, especially in eyes with history of optic neuritis. PMID:27928266
Delas, Barbara; Julio, Gemma; Fernández-Vega, Álvaro; Casaroli-Marano, Ricardo P; Nadal, Jeroni
2017-11-01
To compare the foveal characteristics in fellow eyes (FE) of patients with unilateral idiopathic macular hole without vitreomacular pathologic changes with eyes of healthy controls. Forty-seven FE and 52 eyes of 52 age- and sex-matched healthy controls were studied. Quantitative assessment of the dome-shaped appearance of the hyperreflective lines that represent external limiting membrane (ELM_bulge) and inner outer segment junctions (IS/OS_bulge) were made by optical coherence tomography (OCT) images. Inner retinal complex thickness (IRCT) was quantitatively assessed at 1000 and 2000 μm of the foveal center in nasal and temporal quadrants. Presence of alterations in the inner retinal outer layers and central foveal thickness (CFT) were also analyzed. Significantly lower ELM_bulge (p < 0.0001; Mann-Whitney test) and IS/OS_bulge (p < 0.001; student t test) and higher cases with COST alterations, expressed as a diffuse line (p < 0.006; Chi 2 test) were found in FE than control eyes. IRCT were significantly reduced in FE at all the studied locations when comparing to control eyes (p < 0.05; student t test), maintaining anatomical proportionality among locations. FE without pathologic vitreomacular interactions seems to present some central cone alterations that may be related to other causes than vitreomacular traction.
Subretinal electrical stimulation preserves inner retinal function in RCS rat retina.
Ciavatta, Vincent T; Mocko, Julie A; Kim, Moon K; Pardue, Machelle T
2013-01-01
Previously, studies showed that subretinal electrical stimulation (SES) from a microphotodiode array (MPA) preserves electroretinography (ERG) b-wave amplitude and regional retinal structure in the Royal College of Surgeons (RCS) rat and simultaneously upregulates Fgf2 expression. This preservation appears to be associated with the increased current produced when the MPA is exposed to ERG test flashes, as weekly ERG testing produces greater neuroprotection than biweekly or no testing. Using an infrared source to stimulate the MPA while avoiding potential confounding effects from exposing the RCS retina to high luminance white light, this study examined whether neuroprotective effects from SES increased with subretinal current in a dose-dependent manner. RCS rats (n=49) underwent subretinal implantation surgery at P21 with MPA devices in one randomly selected eye, and the other eye served as the control. Naïve RCS rats (n=25) were also studied. To increase SES current levels, implanted eyes were exposed to 15 min per session of flashing infrared light (IR) of defined intensity, frequency, and duty cycle. Rats were divided into four SES groups that received ERG testing only (MPA only), about 450 µA/cm2 once per week (Low 1X), about 450 µA/cm2 three times per week (Low 3X), and about 1350 µA/cm2 once per week (High 1X). One eye of the control animals was randomly chosen for IR exposure. All animals were followed for 4 weeks with weekly binocular ERGs. A subset of the eyes was used to measure retina Fgf2 expression with real-time reverse-transcription PCR. Eyes receiving SES showed significant preservation of b-wave amplitude, a- and b-wave implicit times, oscillatory potential amplitudes, and post-receptoral parameters (Vmax and log σ) compared to untreated eyes. All SES-treated eyes had similar preservation, regardless of increased SES from IR light exposure. SES-treated eyes tended to have greater retinal Fgf2 expression than untreated eyes, but Fgf2 expression did not increase with IR light. The larger post-receptoral responses (Vmax), greater post-receptoral sensitivity (logσ), and larger oscillatory potentials suggest SES-treated eyes maintained better inner retinal function than the opposite, untreated eyes. This suggests that in addition to preserving photoreceptors in RCS rats, SES may also promote more robust signal transmission through the retinal network compared to the control eyes. These studies suggest that the protective effects of SES on RCS retinal function cannot be improved with additional subretinal current induction from the MPA, or the charge injection provided by ERG Ganzfeld flashes was not adequately mimicked by the flashing IR light used in this study.
Scanning laser polarimetry in eyes with exfoliation syndrome.
Dimopoulos, Antonios T; Katsanos, Andreas; Mikropoulos, Dimitrios G; Giannopoulos, Theodoros; Empeslidis, Theodoros; Teus, Miguel A; Holló, Gábor; Konstas, Anastasios G P
2013-01-01
To compare retinal nerve fiber layer thickness (RNFLT) of normotensive eyes with exfoliation syndrome (XFS) and healthy eyes. Sixty-four consecutive individuals with XFS and normal office-time intraocular pressure (IOP) and 72 consecutive healthy controls were prospectively enrolled for a cross-sectional analysis in this hospital-based observational study. The GDx-VCC parameters (temporal-superior-nasal-inferior-temporal [TSNIT] average, superior average, inferior average, TSNIT standard deviation (SD), and nerve fiber indicator [NFI]) were compared between groups. Correlation between various clinical parameters and RNFLT parameters was investigated with Spearman coefficient. The NFI, although within normal limits for both groups, was significantly greater in the XFS group compared to controls: the respective median and interquartile range (IQR) values were 25.1 (22.0-29.0) vs 15.0 (12.0-20.0), p<0.001. In the XFS group, all RNFLT values were significantly lower compared to controls (p<0.001). However, they were all within the normal clinical ranges for both groups: TSNIT average median (IQR): 52.8 (49.7-55.7) vs 56.0 (53.0-59.3) µm; superior average mean (SD): 62.3 (6.7) vs 68.8 (8.2) µm; inferior average mean (SD): 58.0 (7.2) vs 64.8 (7.7) µm, respectively. TSNIT SD was significantly lower in the XFS group, median (IQR): 18.1 (15.4-20.4) vs 21.0 (18.4-23.8), p<0.001. There was no systematic relationship between RNFLT and visual acuity, cup-to-disc ratio, IOP, central corneal thickness, Humphrey mean deviation, and pattern standard deviation in either group. Compared to control eyes, polarimetry-determined RNFLT was lower in XFS eyes with normal IOP. Therefore, close monitoring of RNFLT may facilitate early identification of those XFS eyes that convert to exfoliative glaucoma.
Hatch, Kathryn M; Schultz, Tim; Talamo, Jonathan H; Dick, H Burkhard
2015-09-01
To compare effective phacoemulsification time (EPT) for the removal of brunescent cataracts treated with femtosecond laser-assisted cataract surgery with standard cataract phacoemulsification techniques. Ruhr University Eye Hospital, Bochum, Germany. Comparative prospective case study. The Lens Opacities Classification System III (LOCS III) grading system was used to measure eyes divided into 4 groups having cataract surgery. Groups 1 and 2 contained eyes with LOCS III grade nuclear opalescence (NO) 3 cataracts treated with standard cataract surgery and femtosecond laser-assisted cataract surgery, respectively. Groups 3 and 4 contained brunescent cataracts, LOCS III grades NO5, treated with standard cataract surgery and femtosecond laser-assisted cataract surgery, respectively. There were 240 eyes, with 60 eyes in each group. The EPT in Group 1 ranged from 0.46 to 3.10 (mean 1.38); the EPT in all eyes in Group 2 was 0 (P < .001). The EPT in Groups 3 and 4 was 2.12 to 19.29 (mean 6.85) and 0 to 6.75 (mean 1.35), respectively (P < .001). A comparison between EPT in Groups 1 and 4 showed that EPT in Group 4 was also lower than in Group 1 (P = .013). Groups 4 and 1 were the most statistically similar of all groups compared, suggesting that EPT for a femtosecond laser-treated grade 5 cataract was most similar to that of a standard-treated grade 3 cataract. Femtosecond laser pretreatment for brunescent cataracts allowed for a significant reduction in EPT compared with manual standard phacoemulsification techniques. Drs. Hatch, Talamo, and Dick are consultants to Abbott Medical Optics, Inc. Dr. Schultz has no financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Anxiety and Sensitivity to Eye Gaze in Emotional Faces
ERIC Educational Resources Information Center
Holmes, Amanda; Richards, Anne; Green, Simon
2006-01-01
This paper reports three studies in which stronger orienting to perceived eye gaze direction was revealed when observers viewed faces showing fearful or angry, compared with happy or neutral, emotional expressions. Gaze-related spatial cueing effects to laterally presented fearful faces and centrally presented angry faces were also modulated by…
Lexical Processes in the Recognition of Japanese Horizontal and Vertical Compounds
ERIC Educational Resources Information Center
Miwa, Koji; Dijkstra, Ton
2017-01-01
This lexical decision eye-tracking study investigated whether horizontal and vertical readings elicit comparable behavioral patterns and whether reading directions modulate lexical processes. Response times and eye movements were recorded during a lexical decision task with Japanese bimorphemic compound words presented vertically. The data were…
Improvement of horizontal macular contraction after surgical removal of epiretinal membranes.
Yang, H K; Kim, S J; Jung, Y S; Kim, K G; Kim, J H; Yu, H G
2011-06-01
To determine whether horizontal macular contraction caused by epiretinal membranes (ERMs) improves after surgical removal. In this prospective, single-center, observational study, 63 consecutive patients with unilateral idiopathic ERM in one eye and no retinal disease in the fellow eye underwent pars plana vitrectomy. Fundus photography and optical coherence tomography (OCT) were performed preoperatively and at 3 months postoperatively. The area enclosed by superior and inferior major vessels from the optic disc to the fovea (area under major vessel (AUV)) and the macroscopic diverging angle (MDA) between superior and inferior major vessels were calculated using digital image analysis of fundus photographs and compared pre- and postoperatively. AUV was significantly smaller in the eyes with ERM compared with the normal fellow eyes (P<0.001). Significant postoperative change in AUV and MDA was demonstrated after ERM removal (P<0.001). However, postoperative AUV of grade 2 and 3 ERM eyes was still significantly smaller than that of normal fellow eyes. Macular thickness differences measured with stratus OCT were positively correlated with AUV differences. Retinal topographic changes caused by ERM improved in part after ERM removal. The improvement of topographic changes were correlated with tomographic changes detected with OCT.
Jee, Donghyun; Park, Sang Hee; Kim, Man Soo; Kim, Eun Chul
2014-07-03
To compare the antioxidant and inflammatory cytokine activities in tears of patients with dry eye syndrome treated with preservative-free versus preserved eye drops. A total of 100 patients with moderate to severe dry eye syndrome were randomly divided into two groups. Fifty patients (group 1) were treated four times with preservative-free 0.1% sodium hyaluronate and 0.1% fluorometholone eye drops in the first month and with preservative-free 0.1% sodium hyaluronate and 0.05% cyclosporine eye drops in the second and third months. Another 50 patients (group 2) were treated with preserved eye drops on the same schedule. Ocular Surface Disease Index, corneal fluorescein staining, Schirmer I test, tear film breakup time, impression cytology, and antioxidant and inflammatory cytokine activities in tears were evaluated. Treatment with preservative-free eye drops led to significant improvements in symptoms, tear film breakup time, Schirmer I score, and impression cytologic findings compared to treatment with preserved eye drops (P < 0.05) in patients with dry eye syndrome. There was a statistically significant decrease in the IL-1β, IL-6, IL-12, and TNF-α concentrations and a statistically significant increase in the catalase, peroxiredoxin 2, superoxide dismutase 2 (SOD 2), and thioredoxin mean fluorescence intensity (MFI) of tears in the preservative-free group at 1, 2, and 3 months compared to initial values, respectively (P < 0.05). Treatment with preservative-free eye drops is effective against the dry eye syndrome. Preservative-free eye drops seem to be more effective than preserved eye drops in decreasing ocular inflammation and in increasing antioxidant contents in tears of patients with dry eye syndrome. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.
Prakash, Gaurav; Srivastava, Dhruv; Choudhuri, Sounak; Bacero, Ruthchel
2016-01-01
Purpose: To compare the ocular monochromatic higher-order aberration. (HOA) profile in normal refractive surgery candidates of Arab and South Asian origin. Methods: This cross-sectional, observational, comparative study was performed in the cornea department of a specialty hospital. Normal refractive surgery candidates with no ocular morbidity except refractive error were recruited. Refractive surgery candidates underwent a preoperative evaluation, including wavefront aberrometry with the iDesign aberrometer (AMO, Inc., Santa Ana, California, United States). The HOA from right eyes were analyzed for HOA signed, absolute, and polar Zernike coefficients. Results: Two hundred Arab participants (group 1) and 200 participants of South-Asian origin (group 2) comprised the study sample. The age and refractive status were comparable between groups. The mean of the HOA root mean square (RMS) was 0.36 ± 17 μ and 0.38 ± 18 μ for Arab and South-Asian eyes, respectively (P < 0.05, rank sum test [RST]). Of the 22 higher order signed Zernike modes, only Z3−3, Z3−1,31, Z4−4, Z4−2, Z40, Z44, and Z5−5 were significantly different from zero (one sample t-test, P < 0.002, with a Bonferroni correction of 0.05/22). All the signed and absolute Zernike terms were comparable between groups (RST, P > 0.002 [0.05/22]). The polar coefficients for coma, trefoil, spherical aberration, and tetrafoil were comparable between groups (P > 0.05, RST). Combined RMS values of third, fourth, fifth, and sixth order also were comparable between groups (P > 0.05, RST). Conclusions: Preoperative whole eye HOA were similar for refractive surgery candidates of Arab and South-Asian origin. The values were comparable to historical data for Caucasian eyes and were lower than Asian (Chinese) eyes. These findings may aid in refining refractive nomograms for wavefront ablations. PMID:26957850
Prakash, Gaurav; Srivastava, Dhruv; Choudhuri, Sounak; Bacero, Ruthchel
2016-01-01
To compare the ocular monochromatic higher-order aberration. (HOA) profile in normal refractive surgery candidates of Arab and South Asian origin. This cross-sectional, observational, comparative study was performed in the cornea department of a specialty hospital. Normal refractive surgery candidates with no ocular morbidity except refractive error were recruited. Refractive surgery candidates underwent a preoperative evaluation, including wavefront aberrometry with the iDesign aberrometer (AMO, Inc., Santa Ana, California, United States). The HOA from right eyes were analyzed for HOA signed, absolute, and polar Zernike coefficients. Two hundred Arab participants (group 1) and 200 participants of South-Asian origin (group 2) comprised the study sample. The age and refractive status were comparable between groups. The mean of the HOA root mean square (RMS) was 0.36 ± 17 μ and 0.38 ± 18 μ for Arab and South-Asian eyes, respectively (P < 0.05, rank sum test [RST]). Of the 22 higher order signed Zernike modes, only Z3 (-3), Z3 (-1),3 (1), Z4 (-4), Z4 (-2), Z4 (0), Z4 (4), and Z5 (-5) were significantly different from zero (one sample t-test, P < 0.002, with a Bonferroni correction of 0.05/22). All the signed and absolute Zernike terms were comparable between groups (RST, P > 0.002 [0.05/22]). The polar coefficients for coma, trefoil, spherical aberration, and tetrafoil were comparable between groups (P > 0.05, RST). Combined RMS values of third, fourth, fifth, and sixth order also were comparable between groups (P > 0.05, RST). Preoperative whole eye HOA were similar for refractive surgery candidates of Arab and South-Asian origin. The values were comparable to historical data for Caucasian eyes and were lower than Asian (Chinese) eyes. These findings may aid in refining refractive nomograms for wavefront ablations.
Short-term effect of beta-adrenoreceptor blocking agents on ocular blood flow.
Sato, T; Muto, T; Ishibashi, Y; Roy, S
2001-10-01
In this study the acute effect of the topically-delivered non-selective beta-blockers timolol and carteolol, and the selective beta-blocker betaxolol, were evaluated with respect to ocular blood flow, intraocular pressure (IOP) and vessel resistance in rabbits' eyes. In a double masked randomized design, one eye of each subject (n = 9) received two drops of 0.5 % timolol or 2 % cartelol or 0.5 % betaxolol ophthalmic solution and a separate group of nine rabbits received two drops of placebo consisting of physiological saline in both eyes to serve as control. Using hydrogen clearance method, ciliary body blood flow (CiBF), choroidal blood flow (CBF), and retinal blood flow (RBF) were measured. IOP and systemic mean arterial pressure (MAP) of each subject were measured under same condition before and after the administration of respective drugs to calculate the ocular perfusion pressure (OPP) and vessel resistance. In timolol- and carteolol-treated eyes significant reduction was observed in IOP (p < 0.01), CiBF (p < 0.01), CBF (p < 0.01) and RBF (p < 0.01) compared to control eyes. However, in betaxolol-treated eyes a marginal reduction in IOP was observed accompanied by significant increase in CiBF (p < 0.01) and RBF (p < 0.05). The non-selective beta-blocker-treated eyes tended to have increased vessel resistance, whereas, selective beta-blocker-treated eyes tended to have decreased vessel resistance. Our current results comparing non-selective and selective beta-blockers suggest that the selective beta-blocker betaxolol may be more appropriate for maintenance of retinal blood flow in situations with low perfusion. Currently the mechanism for regulation of IOP is unclear; however, the findings from this study indicate that decreased CiBF may contribute to reduction in IOP.
Role of percent tissue altered on ectasia after LASIK in eyes with suspicious topography.
Santhiago, Marcony R; Smadja, David; Wilson, Steven E; Krueger, Ronald R; Monteiro, Mario L R; Randleman, J Bradley
2015-04-01
To investigate the association of the percent tissue altered (PTA) with the occurrence of ectasia after LASIK in eyes with suspicious preoperative corneal topography. This retrospective comparative case-control study compared associations of reported ectasia risk factors in 129 eyes, including 57 eyes with suspicious preoperative Placido-based corneal topography that developed ectasia after LASIK (suspect ectasia group), 32 eyes with suspicious topography that remained stable for at least 3 years after LASIK (suspect control group), and 30 eyes that developed ectasia with bilateral normal topography (normal topography ectasia group). Groups were subdivided based on topographic asymmetry into high- or low-suspect groups. The PTA, preoperative central corneal thickness (CCT), residual stromal bed (RSB), and age (years) were evaluated in univariate and multivariate analyses. Average PTA values for normal topography ectasia (45), low-suspect ectasia (39), high-suspect ectasia (36), low-suspect control (32), and high-suspect control (29) were significantly different from one another in all comparisons (P < .003) except high- and low-suspect ectasia groups (P = .033), and presented the highest discriminative capability of all variables evaluated. Age was only significantly different between the high-suspect ectasia and normal topography ectasia groups, and CCT was not significantly different between any groups. Stepwise logistic regression revealed the PTA as the most significant independent variable (P < .0001), with RSB the next most significant parameter. There remains a significant correlation between PTA values and ectasia risk after LASIK, even in eyes with suspicious corneal topography. Less tissue alteration, or a lower PTA value, was necessary to induce ectasia in eyes with more remarkable signs of topographic abnormality, and PTA provided better discriminative capabilities than RSB for all study populations. Copyright 2015, SLACK Incorporated.
Spatola, Ronald; Nadelstein, Brad; Berdoulay, Andrew; English, Robert V
2018-05-01
To evaluate the effect of twice daily aqueous 0.02% sirolimus drops on tear production in normal dogs and dogs with refractory keratoconjunctivitis sicca (KCS). Two groups of dogs were studied. Ten normal dogs with no signs of ocular disease were administered topical 0.02% sirolimus ophthalmic solution in right eye, and a vehicle control in the left eye twice daily for 4 weeks. Complete ophthalmic examinations, including Schirmer tear test were performed weekly. Eighteen dogs with refractory KCS were randomly assigned to receive 0.02% sirolumus ophthalmic solution or 0.02% tacrolimus ophthalmic solution twice daily. Complete ophthalmic examinations were was performed at 2 and 6 weeks following treatment. Tear production in the sirolimus-treated eyes of normal dogs was greater when compared to vehicle controls with a mean difference over all time points of 3.46 mm (95% CI 1.17, 5.75; P = 0.006). After 4 weeks of treatment, the mean difference was 5 mm (95% CI 1.95, 8.05; P = 0.002). In dogs with refractory dry eye, 37.5% of eyes treated with sirolimus exhibited increased tear production >4 mm/min after 6 weeks of treatment, compared to 20% of eyes receiving tacrolimus (P = 0.433). One normal dog experienced topical irritation to both sirolimus and vehicle-treatment. Side effects were not reported in any treated eyes with chronic KCS. Topical 0.02% sirolimus might be an alternative treatment for canine patients with keratoconjunctivits sicca. The drug appears safe when applied topically in an aqueous suspension for up to 6 weeks. While initial results are promising, further studies are warranted. © 2017 American College of Veterinary Ophthalmologists.
Deep Gaze Velocity Analysis During Mammographic Reading for Biometric Identification of Radiologists
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yoon, Hong-Jun; Alamudun, Folami T.; Hudson, Kathy
Several studies have confirmed that the gaze velocity of the human eye can be utilized as a behavioral biometric or personalized biomarker. In this study, we leverage the local feature representation capacity of convolutional neural networks (CNNs) for eye gaze velocity analysis as the basis for biometric identification of radiologists performing breast cancer screening. Using gaze data collected from 10 radiologists reading 100 mammograms of various diagnoses, we compared the performance of a CNN-based classification algorithm with two deep learning classifiers, deep neural network and deep belief network, and a previously presented hidden Markov model classifier. The study showed thatmore » the CNN classifier is superior compared to alternative classification methods based on macro F1-scores derived from 10-fold cross-validation experiments. Our results further support the efficacy of eye gaze velocity as a biometric identifier of medical imaging experts.« less
Deep Gaze Velocity Analysis During Mammographic Reading for Biometric Identification of Radiologists
Yoon, Hong-Jun; Alamudun, Folami T.; Hudson, Kathy; ...
2018-01-24
Several studies have confirmed that the gaze velocity of the human eye can be utilized as a behavioral biometric or personalized biomarker. In this study, we leverage the local feature representation capacity of convolutional neural networks (CNNs) for eye gaze velocity analysis as the basis for biometric identification of radiologists performing breast cancer screening. Using gaze data collected from 10 radiologists reading 100 mammograms of various diagnoses, we compared the performance of a CNN-based classification algorithm with two deep learning classifiers, deep neural network and deep belief network, and a previously presented hidden Markov model classifier. The study showed thatmore » the CNN classifier is superior compared to alternative classification methods based on macro F1-scores derived from 10-fold cross-validation experiments. Our results further support the efficacy of eye gaze velocity as a biometric identifier of medical imaging experts.« less
Kwon, Jin Woo; Choi, Jin A; Shin, Eun Young; La, Tae Yoon; Jee, Dong Hyun; Chung, Yeon Woong; Cho, Yang Kyung
2016-01-01
To evaluate whether trapping vascular endothelial growth factor A (VEGF-A) would suppress angiogenesis and inflammation in dry eye corneas in a murine corneal suture model. We established two groups of animals, one with non-dry eyes and the other with induced dry eyes. In both groups, a corneal suture model was used to induce inflammation and neovascularization. Each of two groups was again divided into three subgroups according to the treatment; subgroup I (aflibercept), subgroup II (dexamethasone) and subgroup III (phosphate buffered saline, PBS). Corneas were harvested and immunohistochemical staining was performed to compare the extents of neovascularization and CD11b+ cell infiltration. Real-time polymerase chain reaction was performed to quantify the expression of inflammatory cytokines and VEGF-A in the corneas. Trapping VEGF-A with aflibercept resulted in significantly decreased angiogenesis and inflammation compared with the dexamethasone and PBS treatments in the dry eye corneas (all P <0.05), but with no such effects in non-dry eyes. The anti-inflammatory and anti-angiogenic effects of VEGF-A trapping were stronger than those of dexamethasone in both dry eye and non-dry eye corneas (all P <0.05). The levels of RNA expression of VEGF-A, TNF-alpha, and IL-6 in the aflibercept subgroup were significantly decreased compared with those in the PBS subgroup in the dry eye group. Compared with non-dry eye corneas, dry eye corneas have greater amounts of inflammation and neovascularization and also have a more robust response to anti-inflammatory and anti-angiogenic agents after ocular surface surgery. Trapping VEGF-A is effective in decreasing both angiogenesis and inflammation in dry eye corneas after ocular surface surgery.
Kwon, Jin Woo; Choi, Jin A; Shin, Eun Young; La, Tae Yoon; Jee, Dong Hyun; Chung, Yeon Woong; Cho, Yang Kyung
2016-01-01
AIM To evaluate whether trapping vascular endothelial growth factor A (VEGF-A) would suppress angiogenesis and inflammation in dry eye corneas in a murine corneal suture model. METHODS We established two groups of animals, one with non-dry eyes and the other with induced dry eyes. In both groups, a corneal suture model was used to induce inflammation and neovascularization. Each of two groups was again divided into three subgroups according to the treatment; subgroup I (aflibercept), subgroup II (dexamethasone) and subgroup III (phosphate buffered saline, PBS). Corneas were harvested and immunohistochemical staining was performed to compare the extents of neovascularization and CD11b+ cell infiltration. Real-time polymerase chain reaction was performed to quantify the expression of inflammatory cytokines and VEGF-A in the corneas. RESULTS Trapping VEGF-A with aflibercept resulted in significantly decreased angiogenesis and inflammation compared with the dexamethasone and PBS treatments in the dry eye corneas (all P<0.05), but with no such effects in non-dry eyes. The anti-inflammatory and anti-angiogenic effects of VEGF-A trapping were stronger than those of dexamethasone in both dry eye and non-dry eye corneas (all P<0.05). The levels of RNA expression of VEGF-A, TNF-alpha, and IL-6 in the aflibercept subgroup were significantly decreased compared with those in the PBS subgroup in the dry eye group. CONCLUSION Compared with non-dry eye corneas, dry eye corneas have greater amounts of inflammation and neovascularization and also have a more robust response to anti-inflammatory and anti-angiogenic agents after ocular surface surgery. Trapping VEGF-A is effective in decreasing both angiogenesis and inflammation in dry eye corneas after ocular surface surgery. PMID:27990354
Yadav, Ravi K; Begum, Viquar U; Addepalli, Uday K; Senthil, Sirisha; Garudadri, Chandra S; Rao, Harsha L
2016-02-01
To compare the abilities of retinal nerve fiber layer (RNFL) parameters of variable corneal compensation (VCC) and enhanced corneal compensation (ECC) algorithms of scanning laser polarimetry (GDx) in detecting various severities of glaucoma. Two hundred and eighty-five eyes of 194 subjects from the Longitudinal Glaucoma Evaluation Study who underwent GDx VCC and ECC imaging were evaluated. Abilities of RNFL parameters of GDx VCC and ECC to diagnose glaucoma were compared using area under receiver operating characteristic curves (AUC), sensitivities at fixed specificities, and likelihood ratios. After excluding 5 eyes that failed to satisfy manufacturer-recommended quality parameters with ECC and 68 with VCC, 56 eyes of 41 normal subjects and 161 eyes of 121 glaucoma patients [36 eyes with preperimetric glaucoma, 52 eyes with early (MD>-6 dB), 34 with moderate (MD between -6 and -12 dB), and 39 with severe glaucoma (MD<-12 dB)] were included for the analysis. Inferior RNFL, average RNFL, and nerve fiber indicator parameters showed the best AUCs and sensitivities both with GDx VCC and ECC in diagnosing all severities of glaucoma. AUCs and sensitivities of all RNFL parameters were comparable between the VCC and ECC algorithms (P>0.20 for all comparisons). Likelihood ratios associated with the diagnostic categorization of RNFL parameters were comparable between the VCC and ECC algorithms. In scans satisfying the manufacturer-recommended quality parameters, which were significantly greater with ECC than VCC algorithm, diagnostic abilities of GDx ECC and VCC in glaucoma were similar.
Do Unilateral Herpetic Stromal Keratitis and Neurotrophic Ulcers Cause Bilateral Dry Eye?
Jabbarvand, Mahmoud; Hashemian, Hesam; Khodaparast, Mehdi; Rafatnejad, Amin; Beheshtnejad, Amirhooshang; Salami, Amir
2015-07-01
To evaluate and compare the ocular surface condition in herpetic interstitial stromal keratitis and neurotrophic ulcer groups and their normal fellow eyes. In this observational, cross-sectional case-control study, 85 consecutive patients were included, including 56 cases of treated herpetic interstitial keratitis and 29 patients with neurotrophic ulcers. Fifty-six age- and sex-matched participants were also recruited from a normal population as the control group. We evaluated and scored the subjective and objective measures of dry eye for both eyes of all patients. Then, we compared the score of the groups with one another and also with the control group. The main outcome measures were the discomfort level, visual symptoms of dry eye, conjunctival injection, conjunctival staining, corneal staining, corneal tear signs of dry eye, meibomian gland dysfunction, tear break-up time, Schirmer test score with anesthesia, and tear osmolarity. The normal fellow eye of the herpetic keratitis group had significantly higher discomfort levels (1.4 ± 0.9 vs. 1.3 ± 0.5, P = 0.003), visual symptoms (1.7 ± 0.8 vs. 1.3 ± 0.7, P = 0.002), tear break-up time (8.3 ± 3.2 vs. 12.1 ± 3.3 seconds, P = 0.003), Schirmer test scores (9.2 ± 3.9 vs. 12.9 ± 3 mm, P = 0.04), and tear osmolarity (9.2 ± 3.9 vs. 12.9 ± 3 mm, P = 0.003) in comparison with normal controls. The normal fellow eyes of the neurotrophic ulcer group had significantly worse values for discomfort level (1.9 ± 0.9 vs. 1.3 ± 0.5, P < 0.001), tear break-up time (7.9 ± 4 vs. 12.1 ± 3.3, P = 0.004), Schirmer test score (8.1 ± 3.9 vs. 12.9 ± 3, P = 0.005), and tear osmolarity (295 ± 9.2 vs. 292.7 ± 5.9, P = 0.02) compared with normal controls. Both eyes of patients with neurotrophic ulcer and interstitial herpetic keratitis have a significantly poorer ocular surface condition compared with that of normal controls.
Mathurm, Manish; Gilhotra, Ritu Mehra
2011-01-01
An attempt has been made in the present study to formulate soluble ocular inserts of aceclofenac to facilitate the bioavailability of the drug into the eye, as no eye drop solution could be formulated. Glycero-gelatin ocular inserts/films were prepared and physicochemical parameters and drug release profiles of glycerol-gelatin films of aceclofenac were compared with surface cross-linked films of similar compositions. Ocular irritation of the developed formulation was also checked by HET-CAM test and efficacy of the developed formulation against prostaglandin-induced ocular inflammation in rabbit eye was determined. The non-cross-linked films showed poor mechanical, physicochemical properties, and very little potential of sustaining drug release, however cross-linking the films enhanced tensile strength by 70%, but elasticity decreased by 95%. The cross-linked ocular inserts showed less swelling than non-cross-linked. Formulation AF8 (20% gelatin and 70% glycerin, treated by cross-linker for 1 h) demonstrated the longest drug release for 24 h. As per the kinetic models all films showed a constant drug release with Higuchi diffusion mechanism. Formulation was found to be practically non-irritant. The optimized formulation was tested and compared with eye drops of aceclofenac for anti-inflammatory activity in rabbits against PGE₂-induced inflammation. In vivo studies with developed formulation indicated a significant inhibition of PGE₂-induced PMN migration as compared to eye drops. In conclusion, ocular inserts of aceclofenac was found promising as it achieved sustained drug release and better pharmacodynamic activity.
Consensual pupillary light response in the red-eared slider turtle (Trachemys scripta elegans).
Dearworth, James R; Sipe, Grayson O; Cooper, Lori J; Brune, Erin E; Boyd, Angela L; Riegel, Rhae A L
2010-03-17
Purpose of this study was to determine if the turtle has a consensual pupillary light response (cPLR), and if so, to compare it to its direct pupillary light response (dPLR). One eye was illuminated with different intensities of light over a four log range while keeping the other eye in darkness. In the eye directly illuminated, pupil diameter was reduced by as much as approximately 31%. In the eye not stimulated by light, pupil diameter was also reduced but less to approximately 11%. When compared to the directly illuminated eye, this generated a ratio, cPLR-dPLR, equal to 0.35. Ratio of slopes for log/linear fits to plots of pupil changes versus retinal irradiance for non-illuminated (-1.27) to illuminated (-3.94) eyes closely matched at 0.32. cPLR had time constants ranging from 0.60 to 1.20min; however, they were comparable and not statistically different from those of the dPLR, which ranged from 1.41 to 2.00min. Application of mydriatic drugs to the directly illuminated eye also supported presence of a cPLR. Drugs reduced pupil constriction by approximately 9% for the dPLR and slowed its time constant to 9.58min while simultaneous enhancing constriction by approximately 6% for the cPLR. Time constant for the cPLR at 1.75min, however, was not changed. Results support that turtle possesses a cPLR although less strong than its dPLR. Copyright 2010 Elsevier Ltd. All rights reserved.
LASIK versus photorefractive keratectomy for high myopic (> 3 diopter) astigmatism.
Katz, Toam; Wagenfeld, Lars; Galambos, Peter; Darrelmann, Benedikt Große; Richard, Gisbert; Linke, Stephan Johannes
2013-12-01
To compare the efficacy, safety, predictability, and vector analysis indices of LASIK and photorefractive keratectomy (PRK) for correction of high cylinder of greater than 3 diopters (D) in myopic eyes. The efficacy, safety, and predictability of LASIK or PRK performed in 114 consecutive randomly selected myopic eyes with an astigmatism of greater than 3 D were retrospectively analyzed at the 2- to 6-month follow-up visits. Vector analysis of the cylindrical correction was compared between the treatment groups. A total of 57 eyes receiving PRK and 57 eyes receiving LASIK of 114 refractive surgery candidates were enrolled in the study. No statistically significant difference in efficacy [efficacy index = 0.76 (±0.32) for PRK vs 0.74 (±0.19) for LASIK (P = .82)], safety [safety index = 1.10 (±0.26) for PRK vs 1.01 (±0.17) for LASIK (P = .121)], or predictability [achieved astigmatism < 1 D in 39% of PRK- and 54% of LASIK-treated eyes, and < 2 D in 88% of PRK- and 89% of LASIK-treated eyes (P = .218)] was demonstrated. Using Alpins vector analysis, the surgically induced astigmatism and difference vector were not significantly different between the surgery methods, whereas the correction index showed a slight and significant advantage of LASIK over PRK (1.25 for PRK and 1.06 for LASIK, P < .001). LASIK and PRK are comparably safe, effective, and predictable procedures for excimer laser correction of high astigmatism of greater than 3 D in myopic eyes. Predictability of the correction of the cylindrical component is lower than that of the spherical equivalent. Copyright 2013, SLACK Incorporated.
Utilisation of eye-care services: the effect of Scotland's free eye examination policy.
Dickey, Heather; Ikenwilo, Divine; Norwood, Patricia; Watson, Verity; Zangelidis, Alexandros
2012-12-01
To examine how the introduction of free eye examinations in Scotland affected people's use of eye care services. Particularly, to assess if more people are now having their eyes examined regularly, and whether there are differences in the way people responded to the policy across socio-economic groups. Using the British Household Panel Survey, eye test uptake and frequency in Scotland is compared to the rest of the UK pre and post policy. Propensity to have eye tests and responsiveness to the policy is compared across socio-economic groups. In addition, using data available from a chain of private ophthalmic opticians, clinical characteristics of eye examination patients are compared pre- and post-policy. There is evidence that suggests that people responded positively to the policy. In particular, a higher percentage of people in Scotland have their eyes tested after the free eye care policy was introduced. Interestingly, the response to the policy varies between the different socio-economic groups. For the highest earners and most educated groups, the proportion of people having an eye test increased more than for those groups with lower income or lower education. Although the policy succeeded in getting more people to have their eyes tested, the socio-economic differences observed suggest that the policy has not reached the more vulnerable segments in society to the same extent, in particular, those with low education and low income. As a result, eye care services utilisation inequalities have widened in Scotland after the free eye care policy was introduced. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Symptoms, visual function, and mucin expression of eyes with tear film instability.
Shimazaki-Den, Seika; Dogru, Murat; Higa, Kazunari; Shimazaki, Jun
2013-09-01
We examined symptoms, tear stability, visual function, and conjunctival cytology in eyes with an unstable tear film (UTF), expressed as a short tear film breakup time without epithelial damage or low tear secretion, and compared the results with those from eyes with aqueous deficiency (AD) associated with epithelial damage, and healthy eyes. We divided the patients with ocular discomfort into 2 groups according to the breakup time, Schirmer value, and epithelial staining score: UTF group (≤5 seconds, >5 mm, and <3 points; 21 eyes of 21 patients) and AD group (≤5 seconds, ≤5 mm, and ≥3 points; 21 eyes of 21 patients). We examined all patients and 17 healthy subjects for symptoms, tear functions, tear film stability by tear film lipid layer interferometry and tear film analysis system, and functional visual acuity. Conjunctival impression cytology was performed to investigate changes in goblet cell density, squamous metaplasia, and messenger RNA expression of MUC5AC and MUC16. The symptom scores, tear film analysis system index, and functional visual acuity testing were significantly worse in the UTF and AD groups compared with those in the control group (P < 0.05). The messenger RNA expression levels of MUC5AC and MUC16 were significantly lower in UTF and AD eyes compared with those in the control eyes (P < 0.0001). An UTF itself can cause dry eye symptoms and visual disturbance comparable with those of AD dry eyes.
Brzheskiy, Vladimir V; Efimova, Elena L; Vorontsova, Tatiana N; Alekseev, Vladimir N; Gusarevich, Olga G; Shaidurova, Ksenia N; Ryabtseva, Alla A; Andryukhina, Olga M; Kamenskikh, Tatiana G; Sumarokova, Elena S; Miljudin, Eugeny S; Egorov, Eugeny A; Lebedev, Oleg I; Surov, Alexander V; Korol, Andrii R; Nasinnyk, Illia O; Bezditko, Pavel A; Muzhychuk, Olena P; Vygodin, Vladimir A; Yani, Elena V; Savchenko, Alla Y; Karger, Elena M; Fedorkin, Oleg N; Mironov, Alexander N; Ostapenko, Victoria; Popeko, Natalia A; Skulachev, Vladimir P; Skulachev, Maxim V
2015-12-01
This article presents the results of an international, multicenter, randomized, double-masked, placebo-controlled clinical study of Visomitin (Mitotech LLC, Moscow, Russian Federation) eye drops in patients with dry eye syndrome (DES). Visomitin is the first registered (in Russia) drug with a mitochondria-targeted antioxidant (SkQ1) as the active ingredient. In this multicenter (10 sites) study of 240 subjects with DES, study drug (Visomitin or placebo) was self-administered three times daily (TID) for 6 weeks, followed by a 6-week follow-up period. Seven in-office study visits occurred every 2 weeks during both the treatment and follow-up periods. Efficacy measures included Schirmer's test, tear break-up time, fluorescein staining, meniscus height, and visual acuity. Safety measures included adverse events, slit lamp biomicroscopy, tonometry, blood pressure, and heart rate. Tolerability was also evaluated. This clinical study showed the effectiveness of Visomitin eye drops in the treatment of signs and symptoms of DES compared with placebo. The study showed that a 6-week course of TID topical instillation of Visomitin significantly improved the functional state of the cornea; Visomitin increased tear film stability and reduced corneal damage. Significant reduction of dry eye symptoms (such as dryness, burning, grittiness, and blurred vision) was also observed. Based on the results of this study, Visomitin is effective and safe for use in eye patients with DES for protection from corneal damage. Mitotech LLC.
Iwata, Yo; Handa, Tomoya; Ishikawa, Hitoshi; Shoji, Nobuyuki; Shimizu, Kimiya
2016-01-01
To investigate the efficacy of an amblyopia treatment program with both eyes open. Ten subjects (mean age 20.5 ± 1.5 years) were enrolled. All subjects had un-remarkable ophthalmic examinations, but several subjects had minor refractive errors. Vision function was evaluated using the 3-D visual function trainer-ORTe. Brain measurements were made using functional near-infrared spectroscopy (fNIRS) to examine the oxygenated hemoglobin (HbO 2 ) concentration change upon visual stimulus presentation. The three conditions were as follows: both eyes open and both eyes stimulated, both eyes open and only one eye stimulated, and one eye open and one eye stimulated. Changes in HbO2 between the rest and stimulation phases were not statistically different between the unilateral and bilateral stimulation conditions with both eyes open. However, HbO 2 change was significantly higher in subjects with both eyes open than in subjects with one eye closed (P < 0.001, all comparisons). Greater activation of the visual cortex is achieved when subjects are treated with both eyes open as compared to subjects with one eye occluded. From a perspective of functional brain activation, amblyopia treatment administered without occluding the healthy eye may provide the greatest therapeutic benefit. © 2016 Board of regents of the University of Wisconsin System, American Orthoptic Journal, Volume 66, 2016, ISSN 0065-955X, E-ISSN 1553-4448.
Farivar, Reza; Thompson, Benjamin; Mansouri, Behzad; Hess, Robert F
2011-12-20
Factors such as strabismus or anisometropia during infancy can disrupt normal visual development and result in amblyopia, characterized by reduced visual function in an otherwise healthy eye and often associated with persistent suppression of inputs from the amblyopic eye by those from the dominant eye. It has become evident from fMRI studies that the cortical response to stimulation of the amblyopic eye is also affected. We were interested to compare the hemodynamic response function (HRF) of early visual cortex to amblyopic vs. dominant eye stimulation. In the first experiment, we found that stimulation of the amblyopic eye resulted in a signal that was both attenuated and delayed in its time to peak. We postulated that this delay may be due to suppressive effects of the dominant eye and, in our second experiment, measured the cortical response of amblyopic eye stimulation under two conditions--where the dominant eye was open and seeing a static pattern (high suppression) or where the dominant eye was patched and closed (low suppression). We found that the HRF in response to amblyopic eye stimulation depended on whether the dominant eye was open. This effect was manifested as both a delayed HRF under the suppressed condition and an amplitude reduction.
Alvi, Rashid; Memon, Muhammad Saleh; Shera, Samad; Mumtaz, Seema N; Shaikh, Sikander Ali; Fahim, Muhammad Faisal
2016-01-01
To determine the visual outcome of laser treatment in clinically significant macular edema. This interventional and qausi experimental study was carried out at Diabetic Association of Pakistan (DAP) during January 2011 and December 2012. Approval was taken from Research Ethical Committee of Isra Postgraduate Institute of Ophthalmology. Records of 925 eyes of 464 patients with "Clinical Significant macular edema" (CSME), treated with laser photocoagulation were analyzed. Best-corrected visual acuity (BCVA) at the time of presentation and at the last follow up, minimum of one year and maximum of 45 months was recorded and compared. SPSS version 20.0 was used to analyze the data. Diabetic retinopathy was found in 20.3% (1777) of 8742 diabetic attending DAP Hospital" amongst whom 39.6% (705) had Sight threatening diabetic retinopathy. Laser was advised in 96.4% (680) individuals, accepted by 70.5% (480) individuals. Amongst 960 eyes of 480 patients who accepted laser, 925 eyes had clinically significant macular edema and 35 eyes had PDR who are not included in this study. Amongst 925 eyes with CSME, Grid laser was done in 913 eyes (99%) and focal laser was done in 12 eyes (1%). After a follow up of 12 to 45 months, it was found that best corrected visual acuity had declined in 2.4% (22) eyes, stabilized in 67% (619) eyes and improved in 30.7% (284) eyes. One line improvement on Snellen's chart was fond in 21.3% (197) eyes, 2 lines in 8% (74) eyes, 3 lines in 1.2% (12) eyes and 4 lines in one (0.1%) eye with p-value of 0.000. Laser therapy is an effective treatment in stabilizing/improving the vision in diabetic macular edema particularly at those centers where only Argon Laser is available and OCF, FFA facilities do not exist.
Alvi, Rashid; Memon, Muhammad Saleh; Shera, Samad; Mumtaz, Seema N.; Shaikh, Sikander Ali; Fahim, Muhammad Faisal
2016-01-01
Objective: To determine the visual outcome of laser treatment in clinically significant macular edema. Methods: This interventional and qausi experimental study was carried out at Diabetic Association of Pakistan (DAP) during January 2011 and December 2012. Approval was taken from Research Ethical Committee of Isra Postgraduate Institute of Ophthalmology. Records of 925 eyes of 464 patients with “Clinical Significant macular edema” (CSME), treated with laser photocoagulation were analyzed. Best-corrected visual acuity (BCVA) at the time of presentation and at the last follow up, minimum of one year and maximum of 45 months was recorded and compared. SPSS version 20.0 was used to analyze the data. Results: Diabetic retinopathy was found in 20.3% (1777) of 8742 diabetic attending DAP Hospital” amongst whom 39.6% (705) had Sight threatening diabetic retinopathy. Laser was advised in 96.4% (680) individuals, accepted by 70.5% (480) individuals. Amongst 960 eyes of 480 patients who accepted laser, 925 eyes had clinically significant macular edema and 35 eyes had PDR who are not included in this study. Amongst 925 eyes with CSME, Grid laser was done in 913 eyes (99%) and focal laser was done in 12 eyes (1%). After a follow up of 12 to 45 months, it was found that best corrected visual acuity had declined in 2.4% (22) eyes, stabilized in 67% (619) eyes and improved in 30.7% (284) eyes. One line improvement on Snellen’s chart was fond in 21.3% (197) eyes, 2 lines in 8% (74) eyes, 3 lines in 1.2% (12) eyes and 4 lines in one (0.1%) eye with p-value of 0.000. Conclusion: Laser therapy is an effective treatment in stabilizing/improving the vision in diabetic macular edema particularly at those centers where only Argon Laser is available and OCF, FFA facilities do not exist. PMID:27882027
Reliability of corneal dynamic scheimpflug analyser measurements in virgin and post-PRK eyes.
Chen, Xiangjun; Stojanovic, Aleksandar; Hua, Yanjun; Eidet, Jon Roger; Hu, Di; Wang, Jingting; Utheim, Tor Paaske
2014-01-01
To determine the measurement reliability of CorVis ST, a dynamic Scheimpflug analyser, in virgin and post-photorefractive keratectomy (PRK) eyes and compare the results between these two groups. Forty virgin eyes and 42 post-PRK eyes underwent CorVis ST measurements performed by two technicians. Repeatability was evaluated by comparing three consecutive measurements by technician A. Reproducibility was determined by comparing the first measurement by technician A with one performed by technician B. Intraobserver and interobserver intraclass correlation coefficients (ICCs) were calculated. Univariate analysis of covariance (ANCOVA) was used to compare measured parameters between virgin and post-PRK eyes. The intraocular pressure (IOP), central corneal thickness (CCT) and 1st applanation time demonstrated good intraobserver repeatability and interobserver reproducibility (ICC ≧ 0.90) in virgin and post-PRK eyes. The deformation amplitude showed a good or close to good repeatability and reproducibility in both groups (ICC ≧ 0.88). The CCT correlated positively with 1st applanation time (r = 0.437 and 0.483, respectively, p<0.05) and negatively with deformation amplitude (r = -0.384 and -0.375, respectively, p<0.05) in both groups. Compared to post-PRK eyes, virgin eyes showed longer 1st applanation time (7.29 ± 0.21 vs. 6.96 ± 0.17 ms, p<0.05) and lower deformation amplitude (1.06 ± 0.07 vs. 1.17 ± 0.08 mm, p < 0.05). CorVis ST demonstrated reliable measurements for CCT, IOP, and 1st applanation time, as well as relatively reliable measurement for deformation amplitude in both virgin and post-PRK eyes. There were differences in 1st applanation time and deformation amplitude between virgin and post-PRK eyes, which may reflect corneal biomechanical changes occurring after the surgery in the latter.
Vision screening of abused and neglected children by the UCLA Mobile Eye Clinic.
Yoo, R; Logani, S; Mahat, M; Wheeler, N C; Lee, D A
1999-07-01
The purpose of our study was to present descriptive findings of ocular abnormalities in vision screening examinations of abused and neglected children. We compared the prevalence and the nature of eye diseases and refractive error between abused and neglected boys staying at the Hathaway Home, a residential facility for abused children, and boys from neighboring Boys and Girls clubs. The children in the study received vision screening examinations through the UCLA Mobile Eye Clinic following a standard format. Clinical data were analyzed by chi-square test. The children with a history of abuse demonstrated significantly higher prevalence of myopia, astigmatism, and external eye disorders. Our study suggests that children with a history of abuse may be at higher risk for visual impairment. These visual impairments may be the long-term sequelae of child abuse.
Zanghi, Brian M
2016-01-01
Rectal body temperature (BT) has been documented in exercising dogs to monitor thermoregulation, heat stress risk, and performance during physical activity. Eye (BT eye ) and ear (BT ear ) temperature measured with infrared thermography (IRT) were compared to rectal (BT rec ) temperature as the reference method and assess alternative sites to track hyperthermia, possibly to establish BT eye IRT as a passive and non-contact method. BT measures were recorded at 09:00, 11:30, 12:30, and 02:30 from Labrador Retrievers ( N = 16) and Beagles ( N = 16) while sedentary and with 30-min play-exercise (pre- and 0, 15, 30-min post-exercise). Total exercise locomotor activity counts were recorded to compare relative intensity of play-exercise between breeds. BT rec , BT eye , and BT ear were measured within 5 min of the target time. Each BT method was analyzed by analysis of variance for main effects of breed and time. Method differences were compared using Bland-Altman plots and linear regression. Sedentary BT differed by breed for BT rec ( p < 0.0001), BT ear ( p < 0.0001), and BT eye ( p = 0.06) with Labs having on average 0.3-0.8°C higher BT compared to Beagles. Readings also declined over time for BT eye ( p < 0.0001) and BT ear ( p < 0.0001), but not for BT rec ( p = 0.63) for both breeds. Total exercise (30-min) activity counts did not differ ( p = 0.53) between breeds. Time and breed interaction was significant in response to exercise for both BT rec and BT ear ( p = 0.035 and p = 0.005, respectively), with a marginal interaction ( p = 0.09) for BT eye . All the three methods detected hyperthermia with Labs having a higher increase compared to Beagles. Both BT ear and BT eye were significantly ( p < 0.0001) related to BT rec in all dogs with sedentary or exercise activity. The relationship between BT eye and BT rec improved when monitoring exercise hyperthermia ( r = 0.674) versus measures at rest ( r = 0.381), whereas BT ear was significantly related to BT rec regardless of activity ( r = 0.615-0.735). Although BT readings were significantly related, method bias ( p < 0.02) was observed for BT eye to slightly underestimate BT rec , whereas no bias was observed between BT ear and BT rec . This study demonstrates that IRT technology effectively measures both ear and eye temperature and enables effective monitoring of BT changes at rest, with exercise, and between breeds. However, ear, and not eye, temperature is a better reflection of rectal temperature.
Association of iris crypts with acute primary angle closure.
Koh, Victor; Chua, Jacqueline; Shi, Yuan; Thakku, Sri Gowtham; Lee, Ryan; Nongpiur, Monisha E; Baskaran, Mani; Kumar, Rajesh S; Perera, Shamira; Aung, Tin; Cheng, Ching-Yu
2017-10-01
To determine the relationship between iris surface features and acute primary angle closure (APAC) in eyes with angle closure. Case-control study involving Asian patients diagnosed with previous APAC, primary angle closure suspect (PACS), primary angle closure (PAC) and primary angle closure glaucoma (PACG) at an eye centre in Singapore between August 2012 and January 2015. Participants underwent ophthalmic examination and digital slit-lamp iris photography. Iris surface features were graded based on crypts, furrows and colour. Fellow eyes of APAC were compared with PACS and PAC/PACG eyes with regard to their iris surface features. Occurrence of APAC. A total of 309 patients (71 APAC, 139 PACS, 47 PAC and 52 PACG) were included (mean age: 67.7±7.2 years and 36.6% male). Compared with PACS, higher crypt grade was significantly associated with lower odds of APAC (OR=0.58 for one grade higher in crypt grade; p=0.027, adjusted for age, gender, ethnicity and pupil diameter). The results remained similar when compared with PAC/PACG group (OR=0.58 for one grade higher in crypt grade; p=0.043). We did not observe any significant associations between iris furrows or colour with presence of APAC. Our study comprising Asian eyes with angle closure suggests that the presence of a higher crypt grading may be protective for APAC. As such, assessing iris surface architecture for crypts could be a new measure for risk stratification of developing APAC in eyes with angle closure. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Stuart, Samuel; Hickey, Aodhán; Galna, Brook; Lord, Sue; Rochester, Lynn; Godfrey, Alan
2017-01-01
Detection of saccades (fast eye-movements) within raw mobile electrooculography (EOG) data involves complex algorithms which typically process data acquired during seated static tasks only. Processing of data during dynamic tasks such as walking is relatively rare and complex, particularly in older adults or people with Parkinson's disease (PD). Development of algorithms that can be easily implemented to detect saccades is required. This study aimed to develop an algorithm for the detection and measurement of saccades in EOG data during static (sitting) and dynamic (walking) tasks, in older adults and PD. Eye-tracking via mobile EOG and infra-red (IR) eye-tracker (with video) was performed with a group of older adults (n = 10) and PD participants (n = 10) (⩾50 years). Horizontal saccades made between targets set 5°, 10° and 15° apart were first measured while seated. Horizontal saccades were then measured while a participant walked and executed a 40° turn left and right. The EOG algorithm was evaluated by comparing the number of correct saccade detections and agreement (ICC 2,1 ) between output from visual inspection of eye-tracker videos and IR eye-tracker. The EOG algorithm detected 75-92% of saccades compared to video inspection and IR output during static testing, with fair to excellent agreement (ICC 2,1 0.49-0.93). However, during walking EOG saccade detection reduced to 42-88% compared to video inspection or IR output, with poor to excellent (ICC 2,1 0.13-0.88) agreement between methodologies. The algorithm was robust during seated testing but less so during walking, which was likely due to increased measurement and analysis error with a dynamic task. Future studies may consider a combination of EOG and IR for comprehensive measurement.
Retina nerve fiber layer and choroidal thickness changes in obstructive sleep apnea syndrome.
Ozge, Gokhan; Dogan, Deniz; Koylu, Mehmet Talay; Ayyildiz, Onder; Akincioglu, Dorukcan; Mumcuoglu, Tarkan; Mutlu, Fatih Mehmet
2016-01-01
The purpose of this study was to determine the effects of obstructive sleep apnea syndrome (OSAS) on the submacular and peripapillary retinal nerve fiber layer (RNFL) and choroidal thickness (ChT). Eighty-four eyes of 42 male patients with OSAS and 112 eyes of 56 aged-matched and body mass index-matched healthy male subjects were enrolled in this case-control study. The ChT and peripapillary RNFL thickness was measured using enhanced depth imaging optical coherence tomography. The ChT and RNFL thickness measurements of the groups were compared, and correlations among the Apnea Hypopnea Index (AHI) values and these measurements were calculated. Right and left eyes were separately evaluated. There were no significant differences in the subfoveal and temporal ChT between the groups (p > 0.05). The OSAS group had significantly thicker ChT at 0.5 and 1.5 mm nasal to the fovea in both eyes than the control group (p < 0.05). The peripapillary ChT were significantly thicker in the OSAS group at all segments except for the temporal and superotemporal segments when compared with the control group (p < 0.05 for all quadrants except temporal and superotemporal). When compared with controls, the OSAS group had significantly thinner nasal RNFL thickness in the right eye (p = 0.01) and thinner mean RNFL thickness in both eyes (p < 0.001). Other RNFL thickness measurements were similar between groups (p > 0.05). Between AHI and mean RNFL thickness showed a median negative correlation (r = - 0.411, p = 0.001). The choroidal thickening in patients with OSAS may be associated with the pathophysiology of the neurodegeneration process of the disease.
Ghoreishi, Mohammad; Naderi Beni, Afsaneh; Naderi Beni, Zahra; Zandi, Alireza; Kianersi, Farzan
2017-12-01
The purpose of this study is to compare visual outcomes of myopic refractive surgery, using tissue saving (TS), a standard ablation profile by a Technolas 217z100, and aberration smart ablation (ASA), an aspheric algorithm by a MEL 80 excimer laser in two eyes of one patient. In this prospective interventional paired-eye controlled study, a total of 100 eyes of 50 participants with myopia with or without astigmatism underwent thin-flap Femto-LASIK, using a Femto LDV femtosecond laser (Ziemer Ophthalmic Systems AG, Port, Switzerland). For each patient, one eye was randomly treated with tissue-saving algorithm (TS group) by the Technolas 217z100 excimer laser and the other eye was treated with optimized smart ablation profile (ASA group) by the MEL 80 excimer laser. Outcome measures were uncorrected distance visual acuities (UDVAs), corrected distance visual acuities (CDVAs), manifest refraction, higher-order aberrations (HOAs), contrast sensitivity, and patient satisfaction 12 months after surgery. At 12 months postoperative, "45 subjects returned with mean" UDVA was - 0.02 ± 0.08 Logarithm of mean angle of resolution (LogMAR) for TS group and - 0.02 ± 0.09 LogMAR for ASA group (P = 0.91). Of the TS eyes, 42/45 (93.3%) and 32/45 (71.1%) were within ± 0.5 D and ± 0.25 D of target refraction, respectively, and of the ASA eyes, 41/45 (91.1%) and 30/45 (66.6%) were within ± 0.5 D and ± 0.25 D of target refraction, respectively. No statistically significant differences were observed between groups in HOAs changes and contrast sensitivity function. Aspheric and non-aspheric LASIKs using the two different excimer lasers provide similar results in myopic and myopic astigmatism patients.
Porcine cataract creation using formalin or microwave treatment for an ophthalmology wet lab.
Machuk, Robert William Andrew; Arora, Sourabh; Kutzner, Morley; Damji, Karim F
2016-08-01
Wet labs are an important part of ophthalmology residency training in order to develop intraocular surgical proficiency. The purpose of this study was to compare the effectiveness of formalin versus microwave treatment to produce porcine cadaveric cataracts. This study was a comparative observational study at a single centre. Cataracts were created through the injection of 0.1 mL of 100% ethanol into the anterior chamber followed by the infiltration of 0.1 mL of 37% formalin using a short 30-gauge needle into the lens by introduction through the pars plana. The comparison group investigated porcine eyes treated with a microwave for 5-13 seconds using a 700 W power setting. Two observers used a validated nuclear opalescence and corneal clarity scale to independently grade the treated eyes. In total, 70 eyes were treated with either formalin or by microwave. The formalin eyes had an average lens opacity score of 0.04 ± 0.03 and 1.91 ± 01.10 pre- and post-treatment (p < 0.001). Microwaved eyes had an average pretreatment lens opacity of score 0.10 ± 0.31, which increased to 2.86 ± 0.1.08 post-treatment (p < 0.001). Post-treatment lens opacity was significantly greater in microwave eyes than in formalin-treated eyes (p = 0.003). Pretreatment corneal clarity was 3.65 ± 0.73 in the formalin group, and 3.70 ± 0.93 in the microwave group. After treatment, there was a significant reduction in corneal clarity within the formalin (3.01 ± 1.04, p = 0.0012) and microwave groups (3.03 ± 1.07, p < 0.001). Porcine eye models provide a realistic way to simulate cataracts and so residents can practice the basics of cataract surgery. Both microwave and formalin-based treatments are able to opacify the porcine lens with acceptable reductions in corneal clarity. Copyright © 2016 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.
Vandermeer, G; Chamy, Y; Pisella, P-J
2018-02-01
Dry eye is defined by a tear film instability resulting in variable but systematic fluctuations in quality of vision. Variability in optical quality can be demonstrated using a double pass aberrometer such as the Optical Quality Analyzing System, Visiometrics (OQAS). The goal of this work is to compare fluctuations in objective quality of vision measured by OQAS between treatment with normal saline eye drops and treatment with carmellose 0.5% and hyaluronic acid 0.1% (Optive Fusion [OF], Allergan) in patients with moderate dry eye syndrome. Optical quality was measured by evaluating the variations in the Optical Scattering Index (OSI) over 20seconds using the OQAS. Inclusion criteria were dry eye syndrome with an ocular surface disease index (OSDI) score >23 treated only with artificial tears. The patients were their own controls: OF in one eye and normal saline in the fellow eye. The choice of the subject eye and control eye was determined in a randomized fashion. OSI variations were measured in each eye before instillation, 5minutes and 2hours after instillation. The primary endpoint was OSI fluctuation over 20seconds of measurement. Secondary endpoints were the number of blinks and patient preference (preferred eye). Preliminary results were obtained on 19 patients. Average OSDI score was 36.8. Visual acuity was 10/10 with no significant difference between the two eyes. Prior to instillation, there was no significant difference between "normal saline" and "OF" eyes in terms of OSI, OSI variability or number of blinks. In the normal saline eye, there were no significant variations in mean OSI, OSI variability, OSI slope, or number of blinks. However, in the "OF" eye, there was a significant variation between initial and 2-hour OSI variability (0.363 versus 0.204, P<0.05), the average slope of OSI (0.04 versus 0.01, P<0.05) and the number of blinks (4.2 versus 2.8, P<0.05). Among the patients, 65% preferred the OF eye, 24% did not have a preference, and 11% preferred the normal saline eye. Objective quality of vision measured by OQAS is an interesting parameter for evaluating the effectiveness of a lacrimal substitute. The purpose of artificial tears is, among other things, to provide comfort and a reduction of dry eye symptoms such as poor quality of vision. This study demonstrates that 0.5% carmellose and 0.1% hyaluronic acid allowed better stabilization of the tear film and thus a significant improvement in the quality of vision compared to normal saline. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Vandermeer, G; Chamy, Y; Pisella, P-J
2018-03-01
Dry eye is defined by a tear film instability resulting in variable but systematic fluctuations in the quality of vision. Variability in optical quality can be demonstrated using a double pass aberrometer such as the OQAS (Optical Quality Analyzing System, Visiometrics). The goal of this work is to compare fluctuations in objective quality of vision measured by OQAS between treatment with normal saline eye drops and treatment with carmellose 0.5% and hyaluronic acid 0.1% (Optive Fusion [OF], Allergan) in patients with moderate dry eye syndrome. Optical quality was measured by evaluating the variations in the Optical Scattering Index (OSI) over 20seconds using the OQAS. Inclusion criteria were dry eye syndrome with an Ocular Surface Disease Index (OSDI) score>23 treated only with artificial tears. The patients were their own controls: OF in one eye and normal saline in the fellow eye. The choice of the subject eye and control eye was determined in a randomized fashion. OSI variations were measured in each eye before instillation, 5minutes and 2hours after instillation. The primary endpoint was OSI fluctuation over 20seconds of measurement. Secondary endpoints were the number of blinks and patient's preference (preferred eye). Preliminary results were obtained on 19 patients. Average OSDI score was 36.8. Visual acuity was 10/10 with no significant difference between the two eyes. Prior to instillation, there was no significant difference between "normal saline" and "OF" eyes in terms of OSI, OSI variability or number of blinks. In the normal saline eye, there was no significant variation in mean OSI, OSI variability, OSI slope, or number of blinks. However, in the "OF" eye, there was a significant variation between initial and 2-hour OSI variability (0.363 versus 0.204; P<0.05), the average slope of OSI (0.04 versus 0.01; P<0.05) and the number of blinks (4.2 versus 2.8; P<0.05). Sixty-five percent of patients preferred the OF eye, 24% did not have a preference, and 11% preferred the normal saline eye. Objective quality of vision measured by OQAS is an interesting parameter for evaluating the effectiveness of a lacrimal substitute. The purpose of artificial tears is, among other things, to provide comfort and a reduction of dry eye symptoms such as poor quality of vision. This study demonstrates that 0.5% carmellose and 0.1% hyaluronic acid allowed better stabilization of the tear film and thus a significant improvement in the quality of vision compared to normal saline. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
Lepore, Domenico; Quinn, Graham E; Molle, Fernando; Baldascino, Antonio; Orazi, Lorenzo; Sammartino, Maria; Purcaro, Velia; Giannantonio, Carmen; Papacci, Patrizia; Romagnoli, Costantino
2014-11-01
To compare the structural outcome at 9 months of eyes treated with intravitreal injection of bevacizumab with fellow eyes treated with conventional laser photoablation in zone I type 1 retinopathy of prematurity (ROP). Single randomized controlled trial. All inborn babies with type 1 zone I ROP at a single institution were included in the study. One eye was randomized to receive an intravitreal injection of 0.5 mg bevacizumab; the fellow eye received conventional laser photoablation. Digital fundus photographs and fluorescein angiography (FA) using the RetCam (Clarity Medical Systems Inc., Pleasanton, CA) were performed before treatment and 9 months after treatment. Presence of retinal and choroidal abnormalities on FA at 9 months. Thirteen infants were enrolled; 1 died 3 months after birth. One laser-treated eye progressed to stage 5 retinal detachment. The remaining 23 eyes had favorable structural results at the 9-month follow-up and provided FA results. At 9 months of age, all eyes treated with a bevacizumab injection were noted to have abnormalities at the periphery (large avascular area, abnormal branching, shunt) or the posterior pole (hyperfluorescent lesion, absence of foveal avascular zone). These posterior and peripheral lesions were not observed in the majority of the lasered eyes. This study documents significant vascular and macular abnormalities of eyes in the bevacizumab group. Long-lasting implications of these abnormalities for visual function of the child need to be studied. Copyright © 2014 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Codreanu, Andrea; Tran, Hoai V; Wiaux, Christophe; Mansouri, Kaweh; Roy, Sylvain; Mermoud, Andre; Schnyder, Corinne
2011-03-01
Study in vivo characteristics of a polymethylmethacrylate (PMMA) implant compared to the standard cylindrical collagen implant for deep sclerectomy (DS). Six-month comparative study. Twenty eyes of ten rabbits. Eyes were randomized to have DS with PMMA implant in one eye and collagen implant in the opposite eye. The growth of the new subconjunctival drainage vessels was assessed by combined fluorescein and indocyanin green anterior segment angiography; intrascleral and subconjunctival blebs were imaged by ultrasound biomicroscopy (UBM). At six months, outflow facility (C) was measured by anterior chamber perfusion and portions of one side of the DS were compared to portions on the 180° opposite side and native sclera on histology. The mean IOP preoperatively and at one, four, twelve, and twenty-four weeks was comparable in both groups (P > 0.1). UBM showed a statistically insignificant quicker regression of the subconjunctival bleb as well as a durable intrascleral lake in the PMMA group (P > 0.05). New drainage vessels were initially observed one month after surgery; they were more numerous in the PMMA group on angiographic and histological findings at 6 months (P < 0.05). The mean C increased significantly after surgery compared to preoperative values (P < 0.05) and no difference was observed between the implants (0.24 ± 0.06 µl/min/mmHg [PMMA] and 0.23 ± 0.07 µl/min/mmHg [collagen implant]) (P = 0.39). Deep sclerectomy performed with PMMA or collagen implants showed similar IOP lowering effects, outflow facility increase, and degree of inflammatory reaction. © 2010 The Authors. Clinical and Experimental Ophthalmology © 2010 Royal Australian and New Zealand College of Ophthalmologists.
Papaconstantinou, Dimitris; Kalantzis, George; Brouzas, Dimitris; Kontaxakis, Anastasios; Koutsandrea, Chryssanthi; Diagourtas, Andreas; Georgalas, Ilias
2016-01-01
The aim of this study was to compare the results of phacoemulsification through a small pupil using minimal iris manipulation versus phacoemulsification through a well-dilated pupil. This prospective randomized control (comparative) study comprised 78 patients (group I) with a maximally dilated pupil size of ≤4.00 mm and 45 patients (group II) with dilated pupil size of ≥7.00 mm. In group I patients, only viscodilation and minimal push-and-pull iris stretching with two collar-button iris-retractor hooks were utilized without iris manipulation. Phacoemulsification was performed by two senior surgeons and the technique used consisted of either stop and chop or quick chop, infusion/aspiration of lens cortex, capsular bag refill with ocular viscoelastic devices, and implantation of an acrylic foldable intraocular lens. Patients were examined on the first day and 1 month postoperatively. Forty-six eyes of group I patients had pseudoexfoliation syndrome, eleven eyes had previous glaucoma surgery, 14 eyes had angle-closure or open-angle glaucoma, and seven eyes had posterior synechiae with iritis. In group I patients, the mean pupil size measured under an operating microscope was 3.2 mm preoperatively, 4.3 mm after viscoelastic and mechanical pupil dilation, and 4.1 mm at the end of a surgical procedure. Rupture of the zonular fibers occurred in six patients of group I and the intraocular lens was implanted in the sulcus. Small iris-sphincter rupture and small hemorrhages occurred in four eyes during pupillary manipulation, but they were not evident at the end of the surgery. In group II patients, no intraoperative complications occurred. Signs of significant corneal edema and iritis were observed more frequently in group I eyes (26 eyes and 20 eyes, respectively) on the first postoperative day in comparison with group II eyes (ten eyes and six eyes, respectively). Intraocular pressure was <20 mmHg in all eyes of both groups. One month postoperatively, the pupil was round and reactive to light, the anterior chamber was quiet, and the cornea was clear in all eyes. The best-corrected visual acuity on Snellen chart was 20/40 (Monoyer's scale) or better in both groups. Phacoemulsification through a small pupil using minimal iris manipulation can be safe and exhibits the same results as those obtained with phacoemulsification through normal pupils.
Eye-related pain induced by visually demanding computer work.
Thorud, Hanne-Mari Schiøtz; Helland, Magne; Aarås, Arne; Kvikstad, Tor Martin; Lindberg, Lars Göran; Horgen, Gunnar
2012-04-01
Eye strain during visually demanding computer work may include glare and increased squinting. The latter may be related to elevated tension in the orbicularis oculi muscle and development of muscle pain. The aim of the study was to investigate the development of discomfort symptoms in relation to muscle activity and muscle blood flow in the orbicularis oculi muscle during computer work with visual strain. A group of healthy young adults with normal vision was randomly selected. Eye-related symptoms were recorded during a 2-h working session on a laptop. The participants were exposed to visual stressors such as glare and small font. Muscle load and blood flow were measured by electromyography and photoplethysmography, respectively. During 2 h of visually demanding computer work, there was a significant increase in the following symptoms: eye-related pain and tiredness, blurred vision, itchiness, gritty eyes, photophobia, dry eyes, and tearing eyes. Muscle load in orbicularis oculi was significantly increased above baseline and stable at 1 to 1.5% maximal voluntary contraction during the working sessions. Orbicularis oculi muscle blood flow increased significantly during the first part of the working sessions before returning to baseline. There were significant positive correlations between eye-related tiredness and orbicularis oculi muscle load and eye-related pain and muscle blood flow. Subjects who developed eye-related pain showed elevated orbicularis oculi muscle blood flow during computer work, but no differences in muscle load, compared with subjects with minimal pain symptoms. Eyestrain during visually demanding computer work is related to the orbicularis oculi muscle. Muscle pain development during demanding, low-force exercise is associated with increased muscle blood flow, possible secondary to different muscle activity pattern, and/or increased mental stress level in subjects experiencing pain compared with subjects with minimal pain.
Moon, Sungbae; Ryoo, Hyun Wook; Ahn, Jae Yun; Park, Jung Bae; Seo, Kang Suk; Shin, Sang Do; Song, Kyoung Jun; Lee, Kang Hyun; Yoo, In Sool; Cho, Jin Seong; Ryu, Hyun Ho; Jeong, Tae Oh; Yeom, Seok Ran; Kim, Young Taek; Hong, Sung Ok
2016-01-01
AIM To investigate the incidence and general characteristics of sports-related eye injuries in patients visiting the Emergency Department. METHODS A cross-sectional, multi-center, observational study. Patients with an injured eye who visited the Emergency Department at one of nine hospitals in Korea were enrolled. All data were prospectively collected between March and September 2010 using a questionnaire. Eye injuries that occurred during risky sports were examined by gender and age. Additionally, the rate of open globe injuries that occurred with and without protective eyewear was examined for each activity. Continuous variables were compared using Student's t-test and categorical variables were compared using Chi-square test. RESULTS A total of 446 patients had sports-related eye injuries. Teenagers (10-19 years old) and young adults (20-29 years old) had the most eye injuries. Eye injuries accounted for 0.2% of Emergency Department patients. Baseball was the most common cause of sports-related eye injuries, followed by soccer and hiking. Protective gear was worn by 9.4% of all patients. Patients that were 30-39 years of age had the highest rate of protective gear use, followed by patients that were 40-49 years of age. The proportion of sports-related eye injuries that were open-globe injuries was highest for soccer and hiking. CONCLUSION Although injuries were most common in patients below the age of 10 years, these patients had the lowest rate of protective eyewear use. Injuries in adults over 40 years of age most commonly occurred during hiking, but the rate of protective eyewear use was low. Young athletes should be educated on and provided with protective eyewear and policies protective gear use should be established. For older adults, eye protection should be encouraged, especially during hiking. PMID:27803871
Takayama, Kohei; Ooto, Sotaro; Hangai, Masanori; Ueda-Arakawa, Naoko; Yoshida, Sachiko; Akagi, Tadamichi; Ikeda, Hanako Ohashi; Nonaka, Atsushi; Hanebuchi, Masaaki; Inoue, Takashi; Yoshimura, Nagahisa
2013-05-01
To detect pathologic changes in retinal nerve fiber bundles in glaucomatous eyes seen on images obtained by adaptive optics (AO) scanning laser ophthalmoscopy (AO SLO). Prospective cross-sectional study. Twenty-eight eyes of 28 patients with open-angle glaucoma and 21 normal eyes of 21 volunteer subjects underwent a full ophthalmologic examination, visual field testing using a Humphrey Field Analyzer, fundus photography, red-free SLO imaging, spectral-domain optical coherence tomography, and imaging with an original prototype AO SLO system. The AO SLO images showed many hyperreflective bundles suggesting nerve fiber bundles. In glaucomatous eyes, the nerve fiber bundles were narrower than in normal eyes, and the nerve fiber layer thickness was correlated with the nerve fiber bundle widths on AO SLO (P < .001). In the nerve fiber layer defect area on fundus photography, the nerve fiber bundles on AO SLO were narrower compared with those in normal eyes (P < .001). At 60 degrees on the inferior temporal side of the optic disc, the nerve fiber bundle width was significantly lower, even in areas without nerve fiber layer defect, in eyes with glaucomatous eyes compared with normal eyes (P = .026). The mean deviations of each cluster in visual field testing were correlated with the corresponding nerve fiber bundle widths (P = .017). AO SLO images showed reduced nerve fiber bundle widths both in clinically normal and abnormal areas of glaucomatous eyes, and these abnormalities were associated with visual field defects, suggesting that AO SLO may be useful for detecting early nerve fiber bundle abnormalities associated with loss of visual function. Copyright © 2013 Elsevier Inc. All rights reserved.
Kałużny, Jakub J; Grzanka, Dariusz; Wiśniewska, Halina; Niewińska, Alicja; Kałużny, Bartłomiej J; Grzanka, Alina
2012-10-01
The purpose of the study is an analysis of intrascleral drainage vessels formed in rabbits' eyes after non-penetrating deep sclerectomy (NPDS) with absorbable and non-absorbable implants, and comparison to eyes in which surgery was performed without implanted material. NPDS was carried out in 12 rabbits, with implantation of non-absorbable methacrylic hydrogel (N=10 eyes) or absorbable cross-linked sodium hyaluronate (N=6 eyes), or without any implant (N=8 eyes). All the animals were euthanized 1 year after surgery. Twenty-one eyeballs were prepared for light microscopy and 3 were prepared for transmission electron microscope (TEM) analysis. Aqueous humour pathways were stained with ferritin in 6 eyeballs. By light microscopy, small vessels adjacent to the areas of scarring were the most common abnormality. Vessel density was significantly higher in operated sclera compared to normal, healthy tissue, regardless of the type of implant used. The average vessel densities were 2.18±1.48 vessels/mm2 in non-implanted sclera, 2.34±1.69 vessels/mm2 in eyes with absorbable implants, and 3.64±1.78 vessels/mm2 in eyes with non-absorbable implants. Analysis of iron distribution in ferritin-injected eyes showed a positive reaction inside new aqueous draining vessels in all groups. TEM analysis showed that the ultrastructure of new vessels matched the features of the small veins. Aqueous outflow after NPDS can be achieved through the newly formed network of small intrascleral veins. Use of non-absorbable implants significantly increases vessel density in the sclera adjacent to implanted material compared to eyes in which absorbable implants or no implants were used.
Sant' Anna, Ana Estela B P P; Hazarbassanov, Rossen M; de Freitas, Denise; Gomes, José Álvaro P
2012-02-01
To evaluate minor salivary glands and labial mucous membrane graft in patients with severe symblepharon and dry eye secondary to Stevens-Johnson syndrome (SJS). A prospective, non-comparative, interventional case series of 19 patients with severe symblepharon and dry eye secondary to SJS who underwent labial mucous membrane and minor salivary glands transplantation. A complete ophthalmic examination including the Schirmer I test was performed prior to and following surgery. All patients had a preoperative Schirmer I test value of zero. Nineteen patients with severe symblepharon and dry eye secondary to SJS were included in the study. There was a statistically significant improvement in the best spectacle-corrected visual acuity in eight patients (t test; p=0.0070). Values obtained in the Schirmer I test improved significantly in 14 eyes (73.7%) 6 months following surgery (χ(2) test; p=0.0094). A statistically significant increase in tear production (Schirmer I test) was found in eyes that received more than 10 glands per graft compared with eyes that received fewer glands (χ(2) test; p=0.0096). Corneal transparency improved significantly in 11 (72.2%) eyes and corneal neovascularisation improved significantly in five eyes (29.4%) (McNemar test; p=0.001 and p=0.0005). The symptoms questionnaire revealed improvement in foreign body sensation in 53.6% of the patients, in photophobia in 50.2% and in pain in 54.8% (Kruskal-Wallis test; p=0.0167). Labial mucous membrane and minor salivary glands transplantation were found to constitute a good option for the treatment of severe symblepharon and dry eye secondary to SJS. This may be considered as a step prior to limbal stem cell and corneal transplantation in these patients.
Lee, Kwan Bok; Koh, Kyung Min; Kwon, Young A; Song, Sang Wroul; Kim, Byoung Yeop; Chung, Jae Lim
2017-08-01
To evaluate changes in the tear meniscus area and tear meniscus height over time in patients with dry eye syndrome, using anterior segment spectral-domain optical coherence tomography after the instillation of 3% diquafosol ophthalmic solution. Sixty eyes from 30 patients with mild to moderate dry eye syndrome were included. Tear meniscus images acquired by anterior segment spectral-domain optical coherence tomography were analyzed using National Institutes of Health's image-analysis software (ImageJ 1.44p). Tear meniscus area and tear meniscus height were measured at baseline, 5 minutes, 10 minutes, and 30 minutes after instillation of a drop of diquafosol in one eye and normal saline in the other eye. Changes in ocular surface disease index score, tear film break-up time, corneal staining score by Oxford schema, and meibomian expressibility were also evaluated at baseline, and after 1 week and 1 month of a diquafosol daily regimen. Sixty eyes from 30 subjects (mean age, 29.3 years; 8 men and 22 women) were included. In eyes receiving diquafosol, tear volume was increased at 5 and 10 minutes compared with baseline. It was also higher than saline instilled eyes at 5, 10, and 30 minutes. Changes in tear volume with respect to baseline were not statistically different after the use of diquafosol for 1 month. Ocular surface disease index score, tear film break-up time, and Oxford cornea stain score were significantly improved after 1 week and 1 month of daily diquafosol instillation, but meibomian expressibility did not change. Topical diquafosol ophthalmic solution effectively increased tear volume for up to 30 minutes, compared to normal saline in patients with dry eye syndrome. © 2017 The Korean Ophthalmological Society
Song, Ha Tae; Kim, Young Jun; Lee, Soo Jung; Moon, Yeon Sung
2007-09-01
To investigate relationships between age, weight, refractive error, and morphologic changes in children's eyes by computerized tomography (CT). Of the 772 eyes of 386 patients under the age of 20 years, who visited our Department of Ophthalmology between January 2005 to August 2006 and underwent CT of the orbit, 406 eyes of 354 patients with clear CT images and normal eyeball contour were enrolled in the present retrospective study. The axial lengths, widths, horizontal and vertical lengths, refractive errors, and body weight of eyes were measured, and relationship between these parameters were investigated. Axial length was found to correlate significantly with eye width (r=0.914), and in emmetropic eyes and myopic eyes, axial lengths and widths were found to increase as age and body weight increased. Axial lengths increased rapidly until age 10, and then increased slowly. In emmetropic eyes, widths/axial lengths increased with age, but in myopic eyes these decreased as age or severity of myopia increased. Moreover, as age increased, the myopic population and severity also increased. The axial length was longer in case of myopia compared to emmetropia in all age groups and there was almost no difference in the increase rate of axial length by the age of myopia and emmetropia. However, the width was wider in case of myopia compared to emmetropia in all age groups and the increase rate of width in myopia by age was smaller than that of emmetropia. Myopia showed decreasing rate of width/axial length with increase of age, from 1.004 in 5 years to 0.971 in 20 years. However, emmetropia showed increasing rate of width/axial length with increase of age, from 0.990 in 5 years to 1.006 in 20 years.
Relations between Age, Weight, Refractive Error and Eye Shape by Computerized Tomography in Children
Song, Ha Tae; Kim, Young Jun; Lee, Soo Jung
2007-01-01
Purpose To investigate relationships between age, weight, refractive error, and morphologic changes in children's eyes by computerized tomography (CT). Methods Of the 772 eyes of 386 patients under the age of 20 years, who visited our Department of Ophthalmology between January 2005 to August 2006 and underwent CT of the orbit, 406 eyes of 354 patients with clear CT images and normal eyeball contour were enrolled in the present retrospective study. The axial lengths, widths, horizontal and vertical lengths, refractive errors, and body weight of eyes were measured, and relationship between these parameters were investigated. Results Axial length was found to correlate significantly with eye width (r=0.914), and in emmetropic eyes and myopic eyes, axial lengths and widths were found to increase as age and body weight increased. Axial lengths increased rapidly until age 10, and then increased slowly. In emmetropic eyes, widths / axial lengths increased with age, but in myopic eyes these decreased as age or severity of myopia increased. Moreover, as age increased, the myopic population and severity also increased. Conclusions The axial length was longer in case of myopia compared to emmetropia in all age groups and there was almost no difference in the increase rate of axial length by the age of myopia and emmetropia. However, the width was wider in case of myopia compared to emmetropia in all age groups and the increase rate of width in myopia by age was smaller than that of emmetropia. Myopia showed decreasing rate of width/axial length with increase of age, from 1.004 in 5 years to 0.971 in 20 years. However, emmetropia showed increasing rate of width/axial length with increase of age, from 0.990 in 5 years to 1.006 in 20 years. PMID:17804923
'Behind blue eyes'†: the association between eye colour and deep infiltrating endometriosis.
Vercellini, Paolo; Buggio, Laura; Somigliana, Edgardo; Dridi, Dhouha; Marchese, Maria Antonietta; Viganò, Paola
2014-10-10
Is the prevalence of blue eye colour higher in women with deep endometriosis? Blue eye colour is more common in women with deep endometriosis when compared with both women with ovarian endometriomas and women without a history of endometriosis. Recent and intriguing evidence suggests that women with deep endometriosis may have particular phenotypic characteristics including a higher prevalence of a light-colour iris. Available epidemiological evidence is however weak. Case-control study performed in a large academic department specializing in the study and treatment of endometriosis. Individual iris colour was evaluated in daylight and categorized in three grades, namely blue-grey (blue), hazel-green (green) and brown. One observer assessed iris colour. In addition, the women themselves were invited to indicate the colour of their eyes according to the same classification system. Cases with discordant eye colour determinations between the observer and the woman were excluded from the final analysis. Two hundred and twenty-three women with deep endometriosis (cases), 247 with ovarian endometriomas and 301 without a history of endometriosis were enrolled. After exclusion of 52 discordant cases, the proportions of brown, blue and green eye colours were, respectively, 61, 30 and 9% in the deep endometriosis group, 74, 16 and 10% in the endometrioma group and 75, 15 and 10% in the non-endometriosis group. Women in the deep endometriosis group had a statistically significant excess of blue eyes and a reduced proportion of brown eyes compared with the two control groups (P = 0.002 and P < 0.001, respectively). The proportion of blue eyes was almost identical in the ovarian endometrioma group and the non-endometriosis group, and that of green eyes was substantially similar in all study groups. The OR (95% CI) of having blue eyes in women with deep endometriosis compared with women with ovarian endometriosis and with those without endometriosis was, respectively, 2.2 (1.4-3.6) and 2.5 (1.6-3.9). We cannot exclude that some women without a previous diagnosis of endometriosis indeed had the disease. However, this would have led to a reduction of the observed difference in proportion of blue eyes, thus to a potential underestimation of the real strength of the association. Moreover, under-ascertainment is possible with regard to peritoneal disease, but unlikely with deep endometriotic lesions and ovarian endometriomas. There are two possible explanations for our findings. Both may have intriguing implications for future research on endometriosis. Firstly, genes involved in the control of iris colour transmission may lie in a region with a strong pattern of linkage disequilibrium with genes involved in the invasiveness of endometriosis. Alternatively, blue eye colour could be considered an indicator of a photo-sensitive phenotype resulting in limited exposure to sunlight and UVB radiation. Limited sunlight exposure is associated with reduced circulating 25-hydroxyvitamin D3, an element that has recently been linked to endometriosis development. © The Author 2014. Published by Oxford University Press on behalf of the European Society of Human Reproduction and Embryology. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Chen, Henry Shen-Lih; Liu, Chun-Hsiu; Lu, Da-Wen
2016-01-01
Background/Purpose: To evaluate and compare the diagnostic discriminative ability for detecting glaucoma in highly myopic eyes from a normative database of macular ganglion cell complex (mGCC) thickness based on nonhighly myopic and highly myopic normal eyes. Methods: Forty-nine eyes of 49 participants with high myopia (axial length ≥ 26.0 mm) were enrolled. Spectral-domain optical coherence tomography scans were done using RS-3000, and the mGCC thickness/significance maps within a 9-mm diameter circle were generated using built-in software. We compared the difference of sensitivity, specificity, and diagnostic accuracy between the nonhighly myopic database and the highly myopic database for differentiating the early glaucomatous eyes from the nonglaucomatous eyes. Results: This study enrolled 15 normal eyes and 34 eyes with glaucoma. The mean mGCC thickness of the glaucoma group was significantly less than that of the normal group (p < 0.001). Sensitivity was 96.3%, and the specificity was 50.0% when using the nonhighly myopic normative database. When the highly myopic normative database was used, the sensitivity was 88.9%, and the specificity was 90.0%. The false positive rate was significantly lower when using the highly myopic normative database (p < 0.05). Conclusion: The evaluations of glaucoma in eyes with high myopia using a nonhighly myopic normative database may lead to a frequent misdiagnosis. When evaluating glaucoma in high myopic eyes, the mGCC thickness determined by the long axial length high myopic normative database should be applied. PMID:29018704
Kassem, Rehab Rashad; El-Mofty, Randa Mohamed Abdel-Moneim; Khodeir, Mustafa Mahmoud; Hamza, Wael Mostafa
2018-03-01
To histopathologically compare the effect of different orientations of cryopreserved human amniotic membrane (AM) transplant during extraocular muscle surgery in rabbits. Fifty-two albino rabbit eyes underwent 4-mm resection of the superior rectus. Eyes were randomly divided into four groups. In Group C (Control group, 16 eyes) the muscle was not wrapped with amniotic membrane. In the three AM groups, cryopreserved AM was wrapped around the muscle, oriented with either its stroma (Group S, 15 eyes) or epithelium (Group E, nine eyes) towards the muscle, or folded on itself with the epithelium externally (Group F, 12 eyes). The rabbits were sacrificed and the eyes were enucleated 6 weeks after surgery. Histopathological examination was conducted for periamniotic, foreign body, scleral, and conjunctival inflammation, conjunctival vascularity, adhesions and muscle fibrosis. In all AM eyes, the AM was surrounded by periamniotic inflammation, with no adhesions detected between the muscle and surrounding tissues in the segment where the AM was present, but detected elsewhere. Adhesions were detected in all group C eyes. Foreign body inflammation was significantly less in Group C than in each of the AM groups (p < .05), but was insignificantly different among the three AM groups (p > .05). Scleral inflammation was absent in all specimens. No significant differences were noted among all groups in terms of conjunctival vascularity, conjunctival inflammation, or muscle fibrosis (p > .05). All AM orientations were equally effective in preventing the development of postoperative adhesions between the extraocular muscle and surrounding tissues.
Piantoni, Giovanni; Cheung, Bing Leung P.; Van Veen, Barry D.; Romeijn, Nico; Riedner, Brady A.; Tononi, Giulio; Van Der Werf, Ysbrand D.; Van Someren, Eus J.W.
2013-01-01
The cingulate cortex is regarded as the backbone of structural and functional connectivity of the brain. While its functional connectivity has been intensively studied, little is known about its effective connectivity, its modulation by behavioral states, and its involvement in cognitive performance. Given their previously reported effects on cingulate functional connectivity, we investigated how eye-closure and sleep deprivation changed cingulate effective connectivity, estimated from resting-state high-density electroencephalography (EEG) using a novel method to calculate Granger Causality directly in source space. Effective connectivity along the cingulate cortex was dominant in the forward direction. Eyes-open connectivity in the forward direction was greater compared to eyes-closed, in well-rested participants. The difference between eyes-open and eyes-closed connectivity was attenuated and no longer significant after sleep deprivation. Individual variability in the forward connectivity after sleep deprivation predicted subsequent task performance, such that those subjects who showed a greater increase in forward connectivity between the eyes-open and the eyes-closed periods also performed better on a sustained attention task. Effective connectivity in the opposite, backward, direction was not affected by whether the eyes were open or closed or by sleep deprivation. These findings indicate that the effective connectivity from posterior to anterior cingulate regions is enhanced when a well-rested subject has his eyes open compared to when they are closed. Sleep deprivation impairs this directed information flow, proportional to its deleterious effect on vigilance. Therefore, sleep may play a role in the maintenance of waking effective connectivity. PMID:23643925
Ocular biometry by computed tomography in different dog breeds.
Chiwitt, Carolin L H; Baines, Stephen J; Mahoney, Paul; Tanner, Andrew; Heinrich, Christine L; Rhodes, Michael; Featherstone, Heidi J
2017-09-01
To (i) correlate B-mode ocular ultrasound (US) and computed tomography (CT) (prospective pilot study), (ii) establish a reliable method to measure the normal canine eye using CT, (iii) establish a reference guide for some dog breeds, (iv) compare eye size between different breeds and breed groups, and (v) investigate the correlation between eye dimensions and body weight, gender, and skull type (retrospective study). B-mode US and CT were performed on ten sheep cadaveric eyes. CT biometry involved 100 adult pure-bred dogs with nonocular and nonorbital disease, representing eleven breeds. Eye length, width, and height were each measured in two of three planes (horizontal, sagittal, and equatorial). B-mode US and CT measurements of sheep cadaveric eyes correlated well (0.70-0.71). The shape of the canine eye was found to be akin to an oblate spheroid (a flattened sphere). A reference guide was established for eleven breeds. Eyes of large breed dogs were significantly larger than those of medium and small breed dogs (P < 0.01), and eyes of medium breed dogs were significantly larger than those of small breed dogs (P < 0.01). Eye size correlated with body weight (0.74-0.82) but not gender or skull type. Computed tomography is a suitable method for biometry of the canine eye, and a reference guide was established for eleven breeds. Eye size correlated with breed size and body weight. Because correlation between B-mode US and CT was shown, the obtained values can be applied in the clinical setting, for example, for the diagnosis of microphthalmos and buphthalmos. © 2016 American College of Veterinary Ophthalmologists.
Klostermann, André; Panchuk, Derek; Farrow, Damian
2018-05-01
The duration of the final fixation before movement initiation - a gaze strategy labelled quiet eye - has been found to explain differences in motor expertise and performance in precision tasks. To date, research only addressed this phenomenon in situations without adversarial constraints. In the present study, we compared the quiet-eye behaviour of intermediately-skilled and highly-skilled basketball players in defended vs. undefended game situations. We predicted differences in quiet-eye duration as a function of skill and performance particularly resulting from late quiet-eye offsets. Results indicated performance-enhancing effects of long quiet-eye durations in the defended but not in the undefended game situation. Furthermore, in line with our prediction, later quiet-eye offsets were associated with superior performance elucidating the phenomenon's relevance in online-demanding motor tasks. Further, earlier quiet-eye onsets were linked to successful performance supporting earlier suggestions that it is not only the duration but also the timing that matters. These findings not only extend the positive effects of the quiet eye in motor performance to dynamic game-play situations but also support the role of the quiet eye in response to programming and information processing respectively.
[Modernized study on eye's signs of blood-stasis syndrome].
Wu, Rui; Xie, Jian-xiang; Zhao, Feng-da
2011-03-01
To make out a computerized formula to diagnose eye's signs of blood-stasis syndrome (BSS), and to improve the previous diagnostic methods by naked eyes. The formula was created by detecting and analyzing the changes of eye's signs in 544 patients (261 of non-BSS and 283 of BSS) quantitatively, adopting computer's color scale principle. And the sensitivity, specificity and accuracy of the formula were verified in 382 patients (97 non-BSS and 285 of BSS). The computerized integral was compared with the naked eye integral, and the normal reference value was calculated with percentile. Various observatory indices of eye's sign were positively correlated with BSS. The specificity of the computerized method was 83.5%, and the diagnostic sensitivity was 89.8%, the accuracy 88.2%, and the correct index 0.733. Comparisons between the computerized integral method and the naked eye integral method showed significant difference in patients of non-BSS or of BSS in various degrees (including mild, moderate and severe) (P < 0.01). The reference value of the naked eye method was below 15. The computerized formula of eye's signs has higher specificity and sensitivity in the diagnosis of BSS, while the naked eye integral method is proved to be useful.
Prevalence and risk factors associated with work-related eye injuries in Bosnia and Herzegovina
Jovanovic, Nina; Peek-Asa, Corinne; Swanton, Amanda; Alajbegovic-Halimic, Jasmina; Cavaljuga, Semra; Nisic, Faruk
2016-01-01
Background Eye injuries are a prevalent workplace injury and cause substantial disability when vision is impaired. Objective To examine work-relatedness of demographic, injury, and clinical characteristics of eye injuries in a large clinic in Bosnia and Herzegovina. Methods We performed a nine-year retrospective study of patients admitted with an eye injury to the Canton Hospital in Zenica, Bosnia and Herzeogvina. Controlling for age and sex, we used logistic regression to examine the influence of work-relatedness on patient and injury characteristics and clinical outcomes. Results Of 258 patients, 71 (27.5%) had work-related and 180 (69.8%) had non-work-related eye injuries. Work-related eye injury was associated with age, education, occupation, and injury type. Agricultural workers were eight times more likely to experience work-related eye injury (95%CI = 1.21–152.0) compared to manual workers. Work-relatedness of injury did not predict final visual acuity or length of hospital stay. Conclusion Promotion of eye safety is needed countrywide. Occupational eye protection is a priority due to the relatively proportion of eye injuries and the workplace being a relatively controlled environment. PMID:27813453
Cinar, Yasin; Cingu, Abdullah Kursat; Turkcu, Fatih Mehmet; Cinar, Tuba; Sahin, Alparslan; Yuksel, Harun; Ari, Seyhmus
2015-03-01
To compare central corneal thickness (CCT) measurements with a rotating Scheimpflug camera (RSC), noncontact specular microscopy (SM), optical low-coherence reflectometry (OLCR), and ultrasonic pachymetry (UP) in keratoconus (KC) patients. In this prospective study, four CCT measurements taken with an RSC, SM, OLCR, and UP were compared in 81 eyes of 44 consecutive KC patients. The KC patients were divided into four subgroups according to Amsler-Krumeich's KC classification. The RSC and UP measurements of the CCT were not statistically significant in all the groups. Comparison of the SM vs. the OLCR measurements yielded statistically significant differences in all the KC patients and in all KC stages. In all the KC patients, RSC and OLCR showed a high correlation coefficient factor (r = 0.87, p = 0.000). CCT measurements with RSC are comparable to those achieved with UP. Compared with the other devices, according to SM measurements, the central cornea is thicker in all keratoconic eyes and in all KC grades, and it is thinner according to OLCR. RSC, UP, SM, and OLCR should not be used interchangeably in keratoconic eyes.
Udani, Jayshree; Vaghela, D. B.; Rajagopala, Manjusha; Matalia, P. D.
2012-01-01
Simple allergic conjunctivitis is the most common form of ocular allergy (prevalence 5 – 22 %). It is a hypersensitivity reaction to specific airborne antigens. The disease Vataja Abhishyanda, which is due to vitiation of Vata Pradhana Tridosha is comparable with this condition. The management of simple allergic conjunctivitis in modern ophthalmology is very expensive and it should be followed lifelong and Ayurveda can provide better relief in such manifestation. This is the first research study on Vataja Abhishyanda. Patients were selected from the Outpatient Department (OPD), Inpatient Department (IPD), of the Shalakya Tantra Department and were randomly divided into two groups. In Group-A Bilvadi Ashchyotana and in Group-B Bilvadi eye drops were instilled for three months. Total 32 patients were registered and 27 patients completed the course of treatment. Bilvadi Ashchyotana gave better results in Toda, Sangharsha, Parushya, Kandu and Ragata as compared with Bilvadi Eye Drops in Vataja Abhishyanda. PMID:23049192
In vivo biometry in the mouse eye with low coherence interferometry.
Schmucker, Christine; Schaeffel, Frank
2004-01-01
A major drawback of the mouse model of myopia is that the ocular dimensions cannot be measured in vivo, and that histological techniques post-mortem suffer from limited resolution. We have tested the potential of a newly developed technique, optical low coherence interferometry (OLCI), adapted for short measurement distances by Meditec, Carl Zeiss, Jena, Germany (the "ACMaster"). Using this technique, ocular biometry was performed in mice with normal vision and after deprivation of form vision. Axial eye length, corneal thickness and anterior chamber depth were measured in 23 mice, aged 25-53 days, and standard deviations from repeated measurements in the same eyes, as well as intra-individual and inter-individual variability were determined in different age groups. The data were compared to those from a preceding study in which biometrical data were obtained from frozen sections [Vision Res. 44 (2004) 1857]. Refractions were measured by automated infrared photorefraction. Mice had either normal visual exposure or were monocularly deprived of form vision for 14 days. Using OLCI, axial length could be determined with an average standard deviation of 8.0 +/- 2.9 microm, corneal thickness with 3.5 +/- 2.1 microm, and anterior chamber depth with 10.6 +/- 12.3 microm. Neither axial length, nor corneal thickness, nor anterior chamber depth were significantly different in left and right eyes of individual mice that had normal visual experience (mean absolute difference between axial lengths: 17 +/- 18 microm, between corneal thickness 5.1 +/- 4.8 microm, and between anterior chamber depths 16.7 +/- 14.8 microm). Compared to the variability that was previously found in frozen sections, the variability of axial length measurements with OLCI was 2.7 times less. After two weeks of form deprivation, OLCI revealed a significant axial elongation in the occluded eyes, compared to the contralateral fellow eyes (+38 +/- 36 microm or 1.16%, p = 0.045, n = 7, paired t-test). In this sample, no accompanying myopic shift was observed in the occluded eyes but this observation is not unexpected given the inherently variable responses of mouse eye growth to visual deprivation. OLCI had sufficient resolution in living mice to detect axial length changes in vivo that were equivalent to a dioptric change of 2 D. Using this technique, it was confirmed that mouse eyes respond to form deprivation by axial elongation, similar to the eyes of other animal models. The lack of a myopic shift in this sample, despite the axial elongation, demonstrates that biometric data are particularly important when the mouse eye is used as a model to study myopia.
Wang, Hao; Crewther, Sheila G.; Liang, Minglong; Laycock, Robin; Yu, Tao; Alexander, Bonnie; Crewther, David P.; Wang, Jian; Yin, Zhengqin
2017-01-01
Strabismic amblyopia is now acknowledged to be more than a simple loss of acuity and to involve alterations in visually driven attention, though whether this applies to both stimulus-driven and goal-directed attention has not been explored. Hence we investigated monocular threshold performance during a motion salience-driven attention task involving detection of a coherent dot motion target in one of four quadrants in adult controls and those with strabismic amblyopia. Psychophysical motion thresholds were impaired for the strabismic amblyopic eye, requiring longer inspection time and consequently slower target speed for detection compared to the fellow eye or control eyes. We compared fMRI activation and functional connectivity between four ROIs of the occipital-parieto-frontal visual attention network [primary visual cortex (V1), motion sensitive area V5, intraparietal sulcus (IPS) and frontal eye fields (FEF)], during a suprathreshold version of the motion-driven attention task, and also a simple goal-directed task, requiring voluntary saccades to targets randomly appearing along a horizontal line. Activation was compared when viewed monocularly by controls and the amblyopic and its fellow eye in strabismics. BOLD activation was weaker in IPS, FEF and V5 for both tasks when viewing through the amblyopic eye compared to viewing through the fellow eye or control participants' non-dominant eye. No difference in V1 activation was seen between the amblyopic and fellow eye, nor between the two eyes of control participants during the motion salience task, though V1 activation was significantly less through the amblyopic eye than through the fellow eye and control group non-dominant eye viewing during the voluntary saccade task. Functional correlations of ROIs within the attention network were impaired through the amblyopic eye during the motion salience task, whereas this was not the case during the voluntary saccade task. Specifically, FEF showed reduced functional connectivity with visual cortical nodes during the motion salience task through the amblyopic eye, despite suprathreshold detection performance. This suggests that the reduced ability of the amblyopic eye to activate the frontal components of the attention networks may help explain the aberrant control of visual attention and eye movements in amblyopes. PMID:28484381
Testa, Francesco; Melillo, Paolo; Rossi, Settimio; Marcelli, Vincenzo; de Benedictis, Antonella; Colucci, Raffaella; Gallo, Beatrice; Brunetti-Pierri, Raffaella; Donati, Simone; Azzolini, Claudio; Marciano, Elio; Simonelli, Francesca
2018-01-01
To investigate the prevalence of macular abnormalities in patients affected by Usher syndrome (USH), by comparing the clinical findings between two types (i.e., USH1 and USH2). A retrospective study was performed by reviewing optical coherence tomography (OCT) in 134 USH patients to determine the presence of macular abnormalities, including cystoid macular edema (CME), epiretinal membrane (ERM), vitreo-macular traction syndrome (VMT), and macular hole (MH). Macular abnormalities were observed in 126/268 (47.0%) examined eyes. The most frequent abnormality was ERM observed in 51 eyes (19%), followed by CME observed in 42 eyes (15.7%). Moreover, CME was significantly (p < 0.05) associated with younger age (CME: 30.1 ± 11.1 years; without CME: 36.9 ± 14.9 years), whereas VMT and full thickness MH were associated with older age (p < 0.05). Moreover, a significantly (p < 0.05) decreased best-corrected visual acuity was associated with MH compared to eyes without MH. Finally, CME was more frequent in USH1 compared to USH2. Our study, for the first time in the literature, showed the distribution of all macular abnormalities assessed by SD-OCT in a large USH cohort, comparing USH1 and USH2 patients. We observed that ocular abnormalities are highly prevalent in USH patients compared to general population, with ERM and CME being the most common alterations. Based on these findings, OCT screening in USH patients is recommended for early detection of macular changes and early treatment.
Triamcinolone Acetonide Decreases Outflow Facility in C57BL/6 Mouse Eyes
Kumar, Sandeep; Shah, Shaily; Deutsch, Emily Rose; Tang, Hai Michael; Danias, John
2013-01-01
Purpose. To determine the effect of triamcinolone acetonide (TA) on outflow facility in mice. Methods. Animals received 20 μL of TA (40 mg/mL) suspension subconjunctivally either bilaterally or unilaterally and were euthanized after either 1 week or 3 weeks. Before mice were killed, IOP was measured with a rebound tonometer. Outflow facility was determined using simultaneous pressure and flow measurements. Another set of animals received bilateral injection of anecortave acetate (AA) with or without bilateral TA injection and their outflow facility was also determined. Myocilin expression was investigated in a subset of eyes using quantitative PCR (qPCR). Results. Outflow facility of eyes in animals receiving bilateral TA injection (TABL) and TA-treated eyes of animals receiving unilateral injection (TAUL) was significantly decreased compared to naïve control eyes (Cnaive) after 1 week and 3 weeks of TA treatment (ANOVA P < 0.01, P < 0.001, respectively). Eyes treated with AA (with or without TA) had higher outflow facility than animals treated with TA (P < 0.05). IOP data did not show any significant difference between groups. qPCR analysis revealed significant decrease in myocilin expression in eyes receiving AA compared to naïve control and TA-treated eyes (ANOVA P < 0.001). Conclusions. Steroid treatment significantly decreases outflow facility in C57BL/6 mice despite having small effect on IOP. This animal model can be useful for studying the pathogenesis of steroid-induced glaucoma. PMID:23322580
Retinotopic maps and foveal suppression in the visual cortex of amblyopic adults
Conner, Ian P; Odom, J Vernon; Schwartz, Terry L; Mendola, Janine D
2007-01-01
Amblyopia is a developmental visual disorder associated with loss of monocular acuity and sensitivity as well as profound alterations in binocular integration. Abnormal connections in visual cortex are known to underlie this loss, but the extent to which these abnormalities are regionally or retinotopically specific has not been fully determined. This functional magnetic resonance imaging (fMRI) study compared the retinotopic maps in visual cortex produced by each individual eye in 19 adults (7 esotropic strabismics, 6 anisometropes and 6 controls). In our standard viewing condition, the non-tested eye viewed a dichoptic homogeneous mid-level grey stimulus, thereby permitting some degree of binocular interaction. Regions-of-interest analysis was performed for extrafoveal V1, extrafoveal V2 and the foveal representation at the occipital pole. In general, the blood oxygenation level-dependent (BOLD) signal was reduced for the amblyopic eye. At the occipital pole, population receptive fields were shifted to represent more parafoveal locations for the amblyopic eye, compared with the fellow eye, in some subjects. Interestingly, occluding the fellow eye caused an expanded foveal representation for the amblyopic eye in one early–onset strabismic subject with binocular suppression, indicating real-time cortical remapping. In addition, a few subjects actually showed increased activity in parietal and temporal cortex when viewing with the amblyopic eye. We conclude that, even in a heterogeneous population, abnormal early visual experience commonly leads to regionally specific cortical adaptations. PMID:17627994
[Evaluation of NAAGA efficacy in dry eye syndrome].
Brignole-Baudouin, F; Robert, P-Y; Creuzot-Garcher, C; Olmiere, C; Delval, L; Baudouin, C
2009-11-01
The aim of this study was to assess the efficacy of Naabak((R)) eyedrops in reducing inflammation in dry eye syndrome. This pilot, multicenter, randomized, double-blind, parallel study was carried out in adult patients suffering from moderate dry eye syndrome. Patients were treated for three months with preservative-free NAAGA (Naabak((R))) or with sodium chloride 0.9% without preservative (Larmabak(R)). They received the treatment four to six times a day during the 1(st) month and three to four times a day during the 2(nd) and 3(rd) months. At each visit (D28 and D84), clinical tests were performed as well as a biological evaluation of HLA-DR and MUC5AC expression on conjunctival imprints using flow cytometry. After three months of treatment, the ocular surface symptoms and overall discomfort were improved in patients treated with Naabak(R) and in those treated with Larmabak(R) with no significant difference between the groups. Cytological impression showed a significant decrease in the expression of inflammatory markers, notably antigen HLA-DR, in the Naabak(R) group. This study confirms the anti-inflammatory property of preservative-free NAAGA (Naabak(R)) in the context of dry eye syndrome with a similar clinical efficacy compared to sodium chloride solution (Larmabak(R)). Naabak(R) could present an additional advantage compared to artificial tears and could be indicated in the treatment of moderate inflammatory dry eye syndrome.
Dry eye symptoms align more closely to non-ocular conditions than to tear film parameters.
Galor, Anat; Felix, Elizabeth R; Feuer, William; Shalabi, Nabeel; Martin, Eden R; Margolis, Todd P; Sarantopoulos, Constantine D; Levitt, Roy C
2015-08-01
To evaluate the relationship between dry eye symptoms, non-ocular conditions and tear film parameters. Cross-sectional study. The study population consisted of patients who were seen in the Miami Veterans Affairs eye clinic. Patients filled out standardised questionnaires assessing dry eye symptoms (dry eye questionnaire 5 (DEQ5) and ocular surface disease index (OSDI)), non-ocular pain, depression and post-traumatic stress disorder (PTSD), and also underwent measurement of tear film parameters. Correlations between dry eye symptoms and non-ocular conditions as compared with tear film parameters. 136 patients with a mean age of 65 (SD 11) years participated in the study. All correlations between the dry eye questionnaire scores (DEQ5 and OSDI) and (A) self-reported non-ocular pain measures (numerical rating scale and pain history), (B) depression and (C) PTSD were significant and moderate in strength (Pearson's coefficient 0.24 to 0.60, p<0.01 for all). All correlations between the dry eye questionnaires and tear film measures were weak (Pearson's coefficient -0.10 to 0.18) and most were not significant. Multivariable linear regression analyses revealed that PTSD and non-ocular pain more closely associated with dry eye symptoms than did tear film parameters. Specifically, non-ocular pain and PTSD accounted for approximately 36% of the variability in DEQ5 scores (R=0.60) and approximately 40% of variability in OSDI scores (R=0.64). Of note, none of the tear parameters remained significantly associated with dry eye symptoms in either model. Dry eye symptoms more closely align to non-ocular pain, depression and PTSD than to tear film parameters. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Biswas, N R; Nainiwal, S K; Das, G K; Langan, U; Dadeya, S C; Mongre, P K; Ravi, A K; Baidya, P
2003-03-01
A comparative randomised double masked multicentric clinical trial has been conducted to find out the efficacy and safety of a herbal eye drop preparation, itone eye drops with artificial tear and placebo in 120 patients with computer vision syndrome. Patients using computer for at least 2 hours continuosly per day having symptoms of irritation, foreign body sensation, watering, redness, headache, eyeache and signs of conjunctival congestion, mucous/debris, corneal filaments, corneal staining or lacrimal lake were included in this study. Every patient was instructed to put two drops of either herbal drugs or placebo or artificial tear in the eyes regularly four times for 6 weeks. Objective and subjective findings were recorded at bi-weekly intervals up to six weeks. Side-effects, if any, were also noted. In computer vision syndrome the herbal eye drop preparation was found significantly better than artificial tear (p < 0.01). No side-effects were noted by any of the drugs. Both subjective and objective improvements were observed in itone treated cases. So, itone can be considered as a useful drug in computer vision syndrome.
Exposure of eyes to perfume: a double-blind, placebo-controlled experiment.
Elberling, J; Duus Johansen, J; Dirksen, A; Mosbech, H
2006-08-01
Environmental perfume exposure can elicit bothersome respiratory symptoms. Symptoms are induced at exposure levels which most people find tolerable, and the mechanisms are unclear. The aim of the study was to investigate patients with eye and respiratory symptoms related to environmental perfume, by exposing the eyes to perfume in a double-blind, placebo-controlled study.Twenty-one eczema patients with respiratory symptoms elicited by perfume were compared with 21 healthy volunteers in a sex- and age-matched case-control study. The participants completed a symptom questionnaire, and underwent a double-blind, placebo-controlled exposure to perfume. Of the 42 individuals tested, 10 had more eye symptoms (irritation, itching, and tears) during perfume exposure than during placebo exposures, and eight of these individuals (P = 0.07, Fisher's exact test) belonged to the patient group. A true positive eye reaction to perfume was significantly associated with identification of perfume as an active exposure (P < 0.05). In this study, vapor of perfume elicited irritation in the eyes independently of olfaction, but the relative importance of ocular chemoperception in relation to elicitation of respiratory symptoms from common environmental exposures to perfume remains unclear. We investigated the hypothesis of an association between respiratory symptoms related to perfume and ocular perfume sensitivity by exposing the eyes to perfume in a double blind, placebo-controlled experiment. Vapors of perfume provoked symptoms in the relevant eye in some patients and healthy control persons, but under our exposure conditions, ocular chemesthesis failed to elicit respiratory symptoms.
COMPARISON OF RETINAL PATHOLOGY VISUALIZATION IN MULTISPECTRAL SCANNING LASER IMAGING.
Meshi, Amit; Lin, Tiezhu; Dans, Kunny; Chen, Kevin C; Amador, Manuel; Hasenstab, Kyle; Muftuoglu, Ilkay Kilic; Nudleman, Eric; Chao, Daniel; Bartsch, Dirk-Uwe; Freeman, William R
2018-03-16
To compare retinal pathology visualization in multispectral scanning laser ophthalmoscope imaging between the Spectralis and Optos devices. This retrospective cross-sectional study included 42 eyes from 30 patients with age-related macular degeneration (19 eyes), diabetic retinopathy (10 eyes), and epiretinal membrane (13 eyes). All patients underwent retinal imaging with a color fundus camera (broad-spectrum white light), the Spectralis HRA-2 system (3-color monochromatic lasers), and the Optos P200 system (2-color monochromatic lasers). The Optos image was cropped to a similar size as the Spectralis image. Seven masked graders marked retinal pathologies in each image within a 5 × 5 grid that included the macula. The average area with detected retinal pathology in all eyes was larger in the Spectralis images compared with Optos images (32.4% larger, P < 0.0001), mainly because of better visualization of epiretinal membrane and retinal hemorrhage. The average detection rate of age-related macular degeneration and diabetic retinopathy pathologies was similar across the three modalities, whereas epiretinal membrane detection rate was significantly higher in the Spectralis images. Spectralis tricolor multispectral scanning laser ophthalmoscope imaging had higher rate of pathology detection primarily because of better epiretinal membrane and retinal hemorrhage visualization compared with Optos bicolor multispectral scanning laser ophthalmoscope imaging.
Kleinhans, Sonja; Herrmann, Eva; Kohnen, Thomas; Bühren, Jens
2017-08-15
Background Iatrogenic keratectasia is one of the most dreaded complications of refractive surgery. In most cases, keratectasia develops after refractive surgery of eyes suffering from subclinical stages of keratoconus with few or no signs. Unfortunately, there has been no reliable procedure for the early detection of keratoconus. In this study, we used binary decision trees (recursive partitioning) to assess their suitability for discrimination between normal eyes and eyes with subclinical keratoconus. Patients and Methods The method of decision tree analysis was compared with discriminant analysis which has shown good results in previous studies. Input data were 32 eyes of 32 patients with newly diagnosed keratoconus in the contralateral eye and preoperative data of 10 eyes of 5 patients with keratectasia after laser in-situ keratomileusis (LASIK). The control group was made up of 245 normal eyes after LASIK and 12-month follow-up without any signs of iatrogenic keratectasia. Results Decision trees gave better accuracy and specificity than did discriminant analysis. The sensitivity of decision trees was lower than the sensitivity of discriminant analysis. Conclusion On the basis of the patient population of this study, decision trees did not prove to be superior to linear discriminant analysis for the detection of subclinical keratoconus. Georg Thieme Verlag KG Stuttgart · New York.
Huang, Ling-Ya; Wang, Yu-Chun; Wu, Chin-Ching
2016-01-01
Floods are known to cause serious environmental damage and health impacts. Studies on flood-related diseases have been primarily on individual events, and limited evidence could be drawn on potential health impacts from floods using large population data. This study used reimbursement records of one million people of the Taiwan National Health Insurance program to compare incident diseases of the eyes, skin and gastrointestinal (GI) tract associated with floods. Incidence rates for the selected diseases were calculated according to outpatient/emergency visit data. The incidence rates were evaluated by flood status: in 10 days before floods, during floods and within 10 days after the floods receded. Outpatient/emergency visit rates for the eye, skin and GI tract diseases were highest after floods and lowest during floods. Results from multivariate Poisson regression analyses showed that, when compared with the incidence in 10 days before floods, the incidence rate ratios (IRR) of diseases within 10 days after floods were 1.15 (95% confidence interval (CI) = 1.10–1.20) for eyes, 1.08 (95% C.I. = 1.05–1.10) for skin, and 1.11 (95% CI = 1.08–1.14) for GI tract, after controlling for covariates. All risks increased with ambient temperature. V-shaped trends were found between age and eye diseases, and between age and GI tract diseases. In contrast, the risk of skin diseases increased with age. In conclusion, more diseases of eyes, skin and GI tract could be diagnosed after the flood. PMID:27171415
The Neural Correlates of Inhibiting Pursuit to Smoothly Moving Targets
ERIC Educational Resources Information Center
Burke, Melanie Rose; Barnes, Graham R.
2011-01-01
A previous study has shown that actively pursuing a moving target provides a predictive motor advantage when compared with passive observation of the moving target while keeping the eyes still [Burke, M. R., & Barnes, G. R. Anticipatory eye movements evoked after active following versus passive observation of a predictable motion stimulus. "Brain…
The Development of Emotional Face and Eye Gaze Processing
ERIC Educational Resources Information Center
Hoehl, Stefanie; Striano, Tricia
2010-01-01
Recent research has demonstrated that infants' attention towards novel objects is affected by an adult's emotional expression and eye gaze toward the object. The current event-related potential (ERP) study investigated how infants at 3, 6, and 9 months of age process fearful compared to neutral faces looking toward objects or averting gaze away…
Perceiving and Remembering Events Cross-Linguistically: Evidence from Dual-Task Paradigms
ERIC Educational Resources Information Center
Trueswell, John C.; Papafragou, Anna
2010-01-01
What role does language play during attention allocation in perceiving and remembering events? We recorded adults' eye movements as they studied animated motion events for a later recognition task. We compared native speakers of two languages that use different means of expressing motion (Greek and English). In Experiment 1, eye movements revealed…
Autistic Symptomatology, Face Processing Abilities, and Eye Fixation Patterns
ERIC Educational Resources Information Center
Kirchner, Jennifer C.; Hatri, Alexander; Heekeren, Hauke R.; Dziobek, Isabel
2011-01-01
Deviant gaze behavior is a defining characteristic of autism. Its relevance as a pathophysiological mechanism, however, remains unknown. In the present study, we compared eye fixations of 20 adults with autism and 21 controls while they were engaged in taking the Multifaceted Empathy Test (MET). Additional measures of face emotion and identity…
Improving College Students English Learning with Dr. Eye Android Mid
ERIC Educational Resources Information Center
Yang, Ju Yin; Che, Pei-Chun
2015-01-01
This paper investigates college students' English language learning through use of Dr. Eye Android handheld mobile Internet device (MID). Compared to related studies, students' English learning using MIDs has not been evaluated and fully understood in the field of higher education. Quantitatively, the researchers used TOEIC pretest and posttest to…
Weber, Arthur J; Viswanáthan, Suresh; Ramanathan, Chidambaram; Harman, Christine D
2010-01-01
To determine whether application of BDNF to the eye and brain provides a greater level of neuroprotection after optic nerve injury than treatment of the eye alone. Retinal ganglion cell survival and pattern electroretinographic responses were compared in normal cat eyes and in eyes that received (1) a mild nerve crush and no treatment, (2) a single intravitreal injection of BDNF at the time of the nerve injury, or (3) intravitreal treatment combined with 1 to 2 weeks of continuous delivery of BDNF to the visual cortex, bilaterally. Relative to no treatment, administration of BDNF to the eye alone resulted in a significant increase in ganglion cell survival at both 1 and 2 weeks after nerve crush (1 week, 79% vs. 55%; 2 weeks, 60% vs. 31%). Combined treatment of the eye and visual cortex resulted in a modest additional increase (17%) in ganglion cell survival in the 1-week eyes, a further significant increase (55%) in the 2-week eyes, and ganglion cell survival levels for both that were comparable to normal (92%-93% survival). Pattern ERG responses for all the treated eyes were comparable to normal at 1 week after injury; however, at 2 weeks, only the responses of eyes receiving the combined BDNF treatment remained so. Although treatment of the eye alone with BDNF has a significant impact on ganglion cell survival after optic nerve injury, combined treatment of the eye and brain may represent an even more effective approach and should be considered in the development of future optic neuropathy-related neuroprotection strategies.
Kim, Yong-Wook; Moon, Sung-Jun
2015-09-01
[Purpose] The purpose of this study was to compare the effect of treadmill walking with the eyes closed and open on the gait and balance abilities of chronic stroke patients. [Subjects and Methods] Thirty patients with chronic stroke participated in this study. The treadmill gait training for each group lasted 40 minutes, and sessions were held 3 times a week for 4 weeks. Gait ability was measured using a Biodex Gait Trainer Treadmill System. Balance ability was measured using a Biodex Balance System. [Results] After the treadmill training' the treadmill training with eyes closed (TEC) group showed significant improvements in walking distance' step length' coefficient of variation' and limit of stability (overall' lateral affected' forward lateral unaffected) compared to the treadmill training with eyes open (TEO) group. [Conclusion] The walking and balance abilities of the TEC participants showed more improvement after the treadmill walking sessions than those of the TEO participants. Therefore' treadmill walking with visual deprivation may be useful for the rehabilitation of patients with chronic stroke.
Madeleine, Pascal; Nielsen, Mogens; Arendt-Nielsen, Lars
2011-04-01
The ability to maintain balance is diminished in patients suffering from a whiplash injury. The aim of this study was to characterize the variability of postural control in patients with chronic whiplash injury. For this purpose, we analyzed static postural recordings from 11 whiplash patients and sex- and age-matched asymptomatic healthy volunteers. Static postural recordings were performed randomly with eyes open, eyes closed, and eyes open and speaking (dual task). Spatial-temporal changes of the center of pressure displacement were analyzed to assess the amplitude and structure of postural variability by computing, respectively, the standard deviation/coefficient of variation and sample entropy/fractal dimension of the time series. The amplitude of variability of the center of pressure was larger among whiplash patients compared with controls (P<0.001) while fractal dimension was lower (P<0.001). The sample entropy increased during both eyes closed and a simple dual task compared with eyes open (P<0.05). The analysis of postural control dynamics revealed increased amplitude of postural variability and decreased signal dimensionality related to the deficit in postural stability found in whiplash patients. Linear and nonlinear analyses can thus be helpful for the quantification of postural control in normal and pathological conditions. Copyright © 2010 Elsevier Ltd. All rights reserved.
The perception of isoluminant coloured stimuli of amblyopic eye and defocused eye
NASA Astrophysics Data System (ADS)
Krumina, Gunta; Ozolinsh, Maris; Ikaunieks, Gatis
2008-09-01
In routine eye examination the visual acuity usually is determined using standard charts with black letters on a white background, however contrast and colour are important characteristics of visual perception. The purpose of research was to study the perception of isoluminant coloured stimuli in the cases of true and simulated amlyopia. We estimated difference in visual acuity with isoluminant coloured stimuli comparing to that for high contrast black-white stimuli for true amblyopia and simulated amblyopia. Tests were generated on computer screen. Visual acuity was detected using different charts in two ways: standard achromatic stimuli (black symbols on a white background) and isoluminant coloured stimuli (white symbols on a yellow background, grey symbols on blue, green or red background). Thus isoluminant tests had colour contrast only but had no luminance contrast. Visual acuity evaluated with the standard method and colour tests were studied for subjects with good visual acuity, if necessary using the best vision correction. The same was performed for subjects with defocused eye and with true amblyopia. Defocus was realized with optical lenses placed in front of the normal eye. The obtained results applying the isoluminant colour charts revealed worsening of the visual acuity comparing with the visual acuity estimated with a standard high contrast method (black symbols on a white background).
NASA Astrophysics Data System (ADS)
Gao, Wei; Zakharov, Valery P.; Myakinin, Oleg O.; Bratchenko, Ivan A.; Artemyev, Dmitry N.; Kornilin, Dmitry V.
2015-07-01
Optical coherence tomography (OCT) is usually employed for the measurement of retinal thickness characterizing the structural changes of tissue. However, fractal dimension (FD) could also character the structural changes of tissue. Therefore, fractal dimension changes may provide further information regarding cellular layers and early damage in ocular diseases. We investigated the possibility of OCT in detecting changes in fractal dimension from layered retinal structures. OCT images were obtained from diabetic patients without retinopathy (DM, n = 38 eyes) or mild diabetic retinopathy (MDR, n = 43 eyes) and normal healthy subjects (Controls, n = 74 eyes). Fractal dimension was calculated using the differentiate box counting methodology. We evaluated the usefulness of quantifying fractal dimension of layered structures in the detection of retinal damage. Generalized estimating equations considering within-subject intereye relations were used to test for differences between the groups. A modified p value of <0.001 was considered statistically significant. Receiver operating characteristic (ROC) curves were constructed to describe the ability of fractal dimension to discriminate between the eyes of DM, MDR and healthy eyes. Significant decreases of fractal dimension were observed in all layers in the MDR eyes compared with controls except in the inner nuclear layer (INL). Significant decreases of fractal dimension were also observed in all layers in the MDR eyes compared with DM eyes. The highest area under receiver operating characteristic curve (AUROC) values estimated for fractal dimension were observed for the outer plexiform layer (OPL) and outer segment photoreceptors (OS) when comparing MDR eyes with controls. The highest AUROC value estimated for fractal dimension were also observed for the retinal nerve fiber layer (RNFL) and OS when comparing MDR eyes with DM eyes. Our results suggest that fractal dimension of the intraretinal layers may provide useful information to differentiate pathological from healthy eyes. Further research is warranted to determine how this approach may be used to improve diagnosis of early retinal neurodegeneration.
Eye Choice for Acquisition of Targets in Alternating Strabismus
Economides, John R.; Adams, Daniel L.
2014-01-01
In strabismus, potentially either eye can inform the brain about the location of a target so that an accurate saccade can be made. Sixteen human subjects with alternating exotropia were tested dichoptically while viewing stimuli on a tangent screen. Each trial began with a fixation cross visible to only one eye. After the subject fixated the cross, a peripheral target visible to only one eye flashed briefly. The subject's task was to look at it. As a rule, the eye to which the target was presented was the eye that acquired the target. However, when stimuli were presented in the far nasal visual field, subjects occasionally performed a “crossover” saccade by placing the other eye on the target. This strategy avoided the need to make a large adducting saccade. In such cases, information about target location was obtained by one eye and used to program a saccade for the other eye, with a corresponding latency increase. In 10/16 subjects, targets were presented on some trials to both eyes. Binocular sensory maps were also compiled to delineate the portions of the visual scene perceived with each eye. These maps were compared with subjects' pattern of eye choice for target acquisition. There was a correspondence between suppression scotoma maps and the eye used to acquire peripheral targets. In other words, targets were fixated by the eye used to perceive them. These studies reveal how patients with alternating strabismus, despite eye misalignment, manage to localize and capture visual targets in their environment. PMID:25355212
Fundus fluorescence Angiography in diagnosing diabetic retinopathy.
Wang, Shuhui; Zuo, Yuqin; Wang, Ning; Tong, Bin
2017-01-01
To investigate the manifestation characteristics of fundus fluorescence angiography (FFA) and its values in diagnosing diabetic retinopathy through comparing direct ophthalmoscopy. Two hundred fifty patients (500 eyes) who were suspected as diabetic retinopathy and admitted to the hospital between February 2015 and December 2016 were selected. They underwent direct ophthalmoscopy and FFA. The manifestation characteristics of FFA in the diagnosis of diabetic retinopathy were summarized. The two examination methods were compared. In the diagnosis with direct ophthalmoscopy, 375 eyes out of 500 eyes were diagnosed as diabetic retinopathy (75%); there were 74 eyes at stage I, 88 eyes at stage II, 92 eyes at stage III, 83 eyes of stage IV, 28 eyes of stage V and 10 eyes of stage VI. In the diagnosis with FFA, 465 eyes out of 500 eyes were diagnosed as diabetic retinopathy (93%); there were 94 eyes at stage I, 110 eyes at stage II, 112 at stage III, 92 eyes at stage IV, 41 eyes at stage V and 16 eyes at stage VI. The detection rate of diabetic retinopathy using FFA was significantly higher than that using direct ophthalmoscopy (P<0.05). FFA found that 316 eyes had non-proliferative retinopathy (67.96%), 75 eyes had pre-proliferative lesions (16.13%), 149 eyes had proliferative lesions (32.04%), 135 eyes had diabetic maculopathy (29.03%) and 31 eyes had diabetic optic disc lesions (6.67%). The detection rate of diabetic retinopathy using FFA is higher than that using direct ophthalmoscopy. FFA could accurately determine clinical stage. Therefore, it is an important approach in treatment efficacy evaluation and treatment guidance, suggesting a significant application value.
Tear production and intraocular pressure in canine eyes with corneal ulceration
Williams, David L.; Burg, Philippa
2017-01-01
This study aimed to evaluate changes in lacrimation and intraocular pressure (IOP) in dogs with unilateral corneal ulceration using the Schirmer tear test (STT) and rebound (TonoVet®) tonometry. IOP and STT values were recorded in both ulcerated and non-ulcerated (control) eyes of 100 dogs diagnosed with unilateral corneal ulceration. Dogs presented with other ocular conditions as their primary complaint were excluded from this study. The mean ± standard deviation for STT values in the ulcerated and control eyes were 20.2±4.6 mm/min and 16.7±3.5 mm/min respectively. The mean ± standard deviation for IOP in the ulcerated and control eyes were 11.9±3.1 mmHg and 16.7±2.6 mmHg respectively. STT values were significantly higher (p<0.000001) in the ulcerated eye compared to the control eye while IOP was significantly lower (p<0.0001). There is an increase in lacrimation and a decrease in IOP in canine eyes with corneal ulceration. The higher tear production in ulcerated eyes shows the importance of measuring STT in both eyes in cases of corneal ulceration, since this increased lacrimation may mask an underlying keratoconjunctivitis sicca only evident in the contralateral eye. The lower IOP in ulcerated eyes is likely to relate to mild uveitic change in the ulcerated eye with a concomitant increase in uveoscleral aqueous drainage. While these changes in tear production and IOP in ulcerated eyes are widely recognised in both human and veterinary ophthalmology, it appears that this is the first controlled documented report of these changes in a large number of individuals. PMID:28616393
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tuulonen, A.; Niva, A.K.; Alanko, H.I.
1987-10-15
We followed up 32 eyes of 32 patients with early glaucoma (22 with capsular glaucoma and ten with simple glaucoma) who received laser trabeculoplasty as a primary therapy. These eyes were compared with a matched control group of 32 eyes treated with medication initially. The success rate (intraocular pressure below 22 mm Hg with laser alone or medication alone) at five years was 50% (16 of 32 eyes) in the laser-treated group and 22% (seven of 32 eyes) in the control group (P less than .02). The control group required more modifications of their therapy to control intraocular pressure. Themore » neuroretinal rim area in the control eyes decreased 2.5 times as much as in the laser group (P = .017). Changes in the Friedmann visual fields did not differ significantly between the two groups.« less
Barrett, Brendan T.; Panesar, Gurvinder K.; Scally, Andrew J.; Pacey, Ian E.
2013-01-01
Background Adults with amblyopia (‘lazy eye’), long-standing strabismus (ocular misalignment) or both typically do not experience visual symptoms because the signal from weaker eye is given less weight than the signal from its fellow. Here we examine the contribution of the weaker eye of individuals with strabismus and amblyopia with both eyes open and with the deviating eye in its anomalous motor position. Methodology/Results The task consisted of a blue-on-yellow detection task along a horizontal line across the central 50 degrees of the visual field. We compare the results obtained in ten individuals with strabismic amblyopia with ten visual normals. At each field location in each participant, we examined how the sensitivity exhibited under binocular conditions compared with sensitivity from four predictions, (i) a model of binocular summation, (ii) the average of the monocular sensitivities, (iii) dominant-eye sensitivity or (iv) non-dominant-eye sensitivity. The proportion of field locations for which the binocular summation model provided the best description of binocular sensitivity was similar in normals (50.6%) and amblyopes (48.2%). Average monocular sensitivity matched binocular sensitivity in 14.1% of amblyopes’ field locations compared to 8.8% of normals’. Dominant-eye sensitivity explained sensitivity at 27.1% of field locations in amblyopes but 21.2% in normals. Non-dominant-eye sensitivity explained sensitivity at 10.6% of field locations in amblyopes but 19.4% in normals. Binocular summation provided the best description of the sensitivity profile in 6/10 amblyopes compared to 7/10 of normals. In three amblyopes, dominant-eye sensitivity most closely reflected binocular sensitivity (compared to two normals) and in the remaining amblyope, binocular sensitivity approximated to an average of the monocular sensitivities. Conclusions Our results suggest a strong positive contribution in habitual viewing from the non-dominant eye in strabismic amblyopes. This is consistent with evidence from other sources that binocular mechanisms are frequently intact in strabismic and amblyopic individuals. PMID:24205005
Liu, Y; Zhang, Y N; Liu, Y; Zhang, J; Li, A P; Liang, Q F; Pan, Z Q
2017-10-01
Lack of willingness to pledge eyes among the general population is the main cause for the shortage of cornea tissue in China. A few studies have implied that general-population adults with specific demographics showed more willingness to donate their eyes. In this study, we analyzed the demographic characteristics of 918 voluntary donors registered in Beijing Tongren Hospital Eye Bank in the past 10 years for possible predictors that might help us to identify potential donors in Beijing and increase the donation rate. All copies of voluntary eye donation application forms filled by the registrants from 2007 to 2016 were collected. Basic demographics listed in the application form were extracted for analysis. Demographics were described as proportions and compared by means of a χ 2 test. Besides that, donor counts and proportions of combining 2 demographics from the 4 main demographics were described and compared. Voluntary donors greater than 50 years of age (n = 477, 53.0%) predominated the proportions. Regarding education level and occupation, donors with tertiary education (n = 484, 57.4%) were more numerous than donors with primary and secondary education (n = 355, 42.1%); office clerks, workers, and government officers were more willing to pledge eyes than were donors engaged in other occupations. In addition, donors of the Han race (n = 856, 94.9%) made up the majority and mainly were distributed in 5 central administrative districts of Beijing (n = 629, 77.5%). The present study suggests that older women (>50 years of age), living in a central district, with higher education level and engaged in white-collar work, were possible predictors for potential donors. Copyright © 2017 Elsevier Inc. All rights reserved.
Superior versus inferior Ahmed glaucoma valve implantation.
Pakravan, Mohammad; Yazdani, Shahin; Shahabi, Camelia; Yaseri, Mehdi
2009-02-01
To compare the efficacy and safety of Ahmed glaucoma valve (AGV) (New World Medical Inc., Rancho Cucamonga, CA) implantation in the superior versus inferior quadrants. Prospective parallel cohort study. A total of 106 eyes of 106 patients with refractory glaucoma. Consecutive patients with refractory glaucoma underwent AGV implantation in the superior or inferior quadrants. Main outcome measures included intraocular pressure (IOP) and rate of complications. Other outcome measures included best corrected visual acuity (BCVA), number of glaucoma medications, and success rate (defined as at least 30% IOP reduction and 5
Diagnostic ability of macular ganglion cell-inner plexiform layer thickness in glaucoma suspects.
Xu, Xiaoyu; Xiao, Hui; Guo, Xinxing; Chen, Xiangxi; Hao, Linlin; Luo, Jingyi; Liu, Xing
2017-12-01
The purpose is to assess the diagnostic ability for early glaucoma of macular ganglion cell-inner plexiform layer (GCIPL) thickness in a Chinese population including glaucoma suspects.A total of 367 eyes with primary open-angle glaucoma (168 early glaucoma, 78 moderate glaucoma, and 121 advanced glaucoma), 52 eyes with ocular hypertension (OHT), 59 eyes with enlarged cup-to-disc ratio (C/D), and 225 normal eyes were included. GCIPL thickness (average, minimum, superotemporal, superior, superonasal, inferonasal, inferior, and inferotemporal), retinal nerve fiber layer (RNFL) thickness, and optic nerve head (ONH) parameters were measured using Cirrus high-definition optical coherence tomography (OCT) and compared. The diagnostic ability of OCT parameters was assessed by area under receiver operating characteristic curve (AUROC) in 3 distinguishing groups: normal eyes and eyes with early glaucoma, normal eyes and eyes with glaucoma regardless of disease stage, and nonglaucomatous eyes (normal eyes, eyes with OHT, and enlarged C/D) and early glaucomatous eyes.Glaucomatous eyes showed a significant reduction in GCIPL thickness compared with nonglaucomatous eyes. In all 3 distinguishing groups, best-performing parameters of GCIPL thickness, RNFL thickness, and ONH parameters were minimum GCIPL thickness (expressed in AUROC, 0.899, 0.952, and 0.900, respectively), average RNFL thickness (0.904, 0.953, and 0.892, respectively), and rim area (0.861, 0.925, and 0.824, respectively). There was no statistical significance of AUROC between minimum GCIPL thickness and average RNFL thickness (all P > .05).GCIPL thickness could discriminate early glaucoma from normal and glaucoma suspects with good sensitivity and specificity. The glaucoma diagnostic ability of GCIPL thickness was comparable to that of RNFL thickness. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.
Remote vs. head-mounted eye-tracking: a comparison using radiologists reading mammograms
NASA Astrophysics Data System (ADS)
Mello-Thoms, Claudia; Gur, David
2007-03-01
Eye position monitoring has been used for decades in Radiology in order to determine how radiologists interpret medical images. Using these devices several discoveries about the perception/decision making process have been made, such as the importance of comparisons of perceived abnormalities with selected areas of the background, the likelihood that a true lesion will attract visual attention early in the reading process, and the finding that most misses attract prolonged visual dwell, often comparable to dwell in the location of reported lesions. However, eye position tracking is a cumbersome process, which often requires the observer to wear a helmet gear which contains the eye tracker per se and a magnetic head tracker, which allows for the computation of head position. Observers tend to complain of fatigue after wearing the gear for a prolonged time. Recently, with the advances made to remote eye-tracking, the use of head-mounted systems seemed destined to become a thing of the past. In this study we evaluated a remote eye tracking system, and compared it to a head-mounted system, as radiologists read a case set of one-view mammograms on a high-resolution display. We compared visual search parameters between the two systems, such as time to hit the location of the lesion for the first time, amount of dwell time in the location of the lesion, total time analyzing the image, etc. We also evaluated the observers' impressions of both systems, and what their perceptions were of the restrictions of each system.
New methods for the assessment of accommodative convergence.
Asakawa, Ken; Ishikawa, Hitoshi; Shoji, Nobuyuki
2009-01-01
The authors introduced a new objective method for measuring horizontal eye movements based on the first Purkinje image with the use of infrared charge-coupled device (CCD) cameras and compared stimulus accommodative convergence to accommodation (AC/A) ratios as determined by a standard gradient method. The study included 20 patients, 5 to 9 years old, who had intermittent exotropia (10 eyes) and accommodative esotropia (10 eyes). Measurement of horizontal eye movements in millimeters (mm), based on the first Purkinje image, was obtained with a TriIRIS C9000 instrument (Hamamatsu Photonics K.K., Hamamatsu, Japan). The stimulus AC/A ratio was determined with the far gradient method. The average values of horizontal eye movements (mm) and eye deviation (Delta) (a) before and (b) after an accommodative stimulus of 3.00 diopters (D) were calculated with the following formula: horizontal eye movements (mm/D) and stimulus AC/A ratio (Delta/D) = (b - a)/3. The average values of the horizontal eye movements and the stimulus AC/A ratio were 0.5 mm/D and 3.8 Delta/D, respectively. Correlation analysis showed a strong positive correlation between these two parameters (r = 0.92). Moreover, horizontal eye movements are directly proportional to the AC/A ratio measured with the gradient method. The methods used in this study allow objective recordings of accommodative convergence to be obtained in many clinical situations. Copyright 2009, SLACK Incorporated.
A hybrid method in combining treatment effects from matched and unmatched studies.
Byun, Jinyoung; Lai, Dejian; Luo, Sheng; Risser, Jan; Tung, Betty; Hardy, Robert J
2013-12-10
The most common data structures in the biomedical studies have been matched or unmatched designs. Data structures resulting from a hybrid of the two may create challenges for statistical inferences. The question may arise whether to use parametric or nonparametric methods on the hybrid data structure. The Early Treatment for Retinopathy of Prematurity study was a multicenter clinical trial sponsored by the National Eye Institute. The design produced data requiring a statistical method of a hybrid nature. An infant in this multicenter randomized clinical trial had high-risk prethreshold retinopathy of prematurity that was eligible for treatment in one or both eyes at entry into the trial. During follow-up, recognition visual acuity was accessed for both eyes. Data from both eyes (matched) and from only one eye (unmatched) were eligible to be used in the trial. The new hybrid nonparametric method is a meta-analysis based on combining the Hodges-Lehmann estimates of treatment effects from the Wilcoxon signed rank and rank sum tests. To compare the new method, we used the classic meta-analysis with the t-test method to combine estimates of treatment effects from the paired and two sample t-tests. We used simulations to calculate the empirical size and power of the test statistics, as well as the bias, mean square and confidence interval width of the corresponding estimators. The proposed method provides an effective tool to evaluate data from clinical trials and similar comparative studies. Copyright © 2013 John Wiley & Sons, Ltd.
Mearza, Ali A; Muhtaseb, Mohammed; Aslanides, Ioannis M
2008-11-01
To compare the safety, efficacy, and predictability of LASIK with the SCHWIND ESIRIS and WaveLight ALLEGRETTO WAVE Eye-Q excimer laser platforms. This prospective study comprised 44 eyes of 22 consecutive patients who were treated with LASIK using the Moria M2 microkeratome. One eye was treated with the SCHWIND ESIRIS laser and the fellow eye treated with the WaveLight ALLEGRETTO WAVE Eye-Q laser. All eyes operated with the SCHWIND ESIRIS were treated with standard aspheric ablation, whereas the eyes operated with the WaveLight ALLEGRETTO WAVE Eye-Q received treatment with three different ablation types according to the common practice at our clinic. Outcome measures were uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), manifest refraction, and proximity to target refraction at 6-month follow-up. At 6 months postoperative, mean decimal UCVA was 0.96+/-0.22 (range: 0.3 to 1.2) for ESIRIS eyes and 0.98+/-0.17 (range: 0.6 to 1.2) for ALLEGRETTO eyes (P=.57). Mean postoperative spherical equivalent refraction was -0.02+/-0.28 diopters (D) (range: -0.75 to +0.75 D) for ESIRIS eyes and 0.11+/-0.91 D (range: -1.00 to +3.88 D) for ALLEGRETTO eyes (P=.49). Of the ESIRIS eyes, 20/22 (91%) were within +/-1.00 D of target refraction and 20/22 (91%) were within +/-0.50 D of target refraction. Of the ALLEGRETTO eyes, 20/22 (91%) and 19/22 (86%) were within +/-1.00 D and +/-0.50 D, respectively, of target refraction. No patient lost > or =2 lines of BSCVA in either group. No differences were seen in safety and efficacy outcome parameters between the SCHWIND ESIRIS and WaveLight ALLEGRETTO WAVE Eye-Q excimer lasers when used according to a previously established treatment algorithm at our clinic in the treatment of refractive error.
Ra, Shugyoku; Ayaki, Masahiko; Yuki, Kenya; Tsubota, Kazuo; Negishi, Kazuno
2017-01-01
Prior studies suggested that glaucoma patients suffer worse dry eye and mood and sleep disorders than non-glaucoma subjects. Prostaglandin analogues are first-line therapy for glaucoma, inducing few instillation problems and sufficient pressure-reduction effects. This study compared dry eye, sleep quality, and mood status between glaucoma patients receiving prostaglandin monotherapy and non-glaucoma subjects. This cross-sectional study evaluated 1520 patients (579 males and 941 females) for glaucoma status and dry eye-related symptoms (dryness, eye fatigue, photophobia, pain, blurring) and signs (Schirmer test, tear break-up time, corneal staining scores). Of the total cohort, 93 patients were also evaluated by Pittsburgh sleep quality index (PSQI) and hospital anxiety and depression score (HADS). Inclusion criteria were consecutive patients ≥ 51 years of age and best-corrected visual acuity ≥ 20/25. Glaucoma patients included those treated with prostaglandin or a fixed combination including prostaglandin. Exclusion criteria were history of ocular surgery within one month. Data were analyzed using the chi-square or Mann-Whitney U tests, at 5% significance. There were no significant differences in dry eye-related signs and symptoms between the control (n = 1431, mean age of 66.9 years) and glaucoma groups (n = 89, 67.9 years). The psychiatric sub-analysis of the control (n = 61, 66.2 years) and glaucoma groups (n = 32, 67.3 years) revealed mean scores of 5.02 ± 3.10 and 5.16 ± 3.46 for PSQI (normal range ≤ 5), 9.47 ± 5.61 and 9.42 ± 7.36 for HADS (normal range ≤ 10), 4.84 ± 3.22 and 4.71 ± 3.45 for anxiety (normal range ≤ 5), and 4.63 ± 3.05 and 4.71 ± 4.40 for depression (normal range ≤ 5), respectively, without statistical significance. Our results were comparable between glaucoma patients on prostaglandin monotherapy and non-glaucoma subjects for dry eye-related clinical manifestations, sleep quality, and mood status.
Mucin deficiency causes functional and structural changes of the ocular surface.
Floyd, Anne M; Zhou, Xu; Evans, Christopher; Rompala, Olivia J; Zhu, Lingxiang; Wang, Mingwu; Chen, Yin
2012-01-01
MUC5AC is the most abundant gel-forming mucin in the ocular system. However, the specific function is unknown. In the present study, a Muc5ac knockout (KO) mouse model was subject to various physiological measurements as compared to its wide-type (WT) control. Interestingly, when KO mice were compared to WT mice, the mean tear break up time (TBUT) values were significantly lower and corneal fluorescein staining scores were significantly higher. But the tear volume was not changed. Despite the lack of Muc5ac expression in the conjunctiva of KO mice, Muc5b expression was significantly increased in these mice. Corneal opacification, varying in location and severity, was found in a few KO mice but not in WT mice. The present results suggest a significant difference in the quality, but not the quantity, of tear fluid in the KO mice compared to WT mice. Dry eye disease is multifactorial and therefore further evaluation of the varying components of the tear film, lacrimal unit and corneal structure of these KO mice may help elucidate the role of mucins in dry eye disease. Because Muc5ac knockout mice have clinical features of dry eye, this mouse model will be extremely useful for further studies regarding the pathophysiology of the ocular surface in dry eye in humans.
Yu, Seong Hun; Sim, Yong Hyeon; Kim, Myung Hoon; Bang, Ju Hee; Son, Kyung Hyun; Kim, Jae Woong; Kim, Hyun Jin
2016-10-01
[Purpose] This study is designed to compare the effects of abdominal drawing-in exercise and myofascial release on pain, flexibility, and balance of elderly females. [Subjects and Methods] Forty elderly females aged 65 or older who had complained of low back pain for three months or longer were selected as the subjects. They were randomly and equally assigned to either an abdominal drawing-in group or a myofascial release group. The subjects conducted exercise three times per week, 40 minutes each time, for eight weeks. As evaluation tools, visual analogue scale for pain, remodified schober test for flexibility, and upright posture with eye opening on hard platform, upright posture with eye closing on hard platform, upright posture with eye opening on soft platform, upright posture with eye closing on soft platform using tetrax for balance were used. [Results] The abdominal drawing-in exercise group saw significant difference in pain and balance after the exercise compared to before the exercise. The myofascial release group saw significant difference in pain and flexibility after exercise compared to before the exercise. [Conclusion] The above study showed that abdominal drawing-in exercise affected elderly females regarding pain and balance and myofascial release influenced their pain and flexibility.
Comparison of laser ray-tracing and skiascopic ocular wavefront-sensing devices
Bartsch, D-UG; Bessho, K; Gomez, L; Freeman, WR
2009-01-01
Purpose To compare two wavefront-sensing devices based on different principles. Methods Thirty-eight healthy eyes of 19 patients were measured five times in the reproducibility study. Twenty eyes of 10 patients were measured in the comparison study. The Tracey Visual Function Analyzer (VFA), based on the ray-tracing principle and the Nidek optical pathway difference (OPD)-Scan, based on the dynamic skiascopy principle were compared. Standard deviation (SD) of root mean square (RMS) errors was compared to verify the reproducibility. We evaluated RMS errors, Zernike terms and conventional refractive indexes (Sph, Cyl, Ax, and spherical equivalent). Results In RMS errors reading, both devices showed similar ratios of SD to the mean measurement value (VFA: 57.5±11.7%, OPD-Scan: 53.9±10.9%). Comparison on the same eye showed that almost all terms were significantly greater using the VFA than using the OPD-Scan. However, certain high spatial frequency aberrations (tetrafoil, pentafoil, and hexafoil) were consistently measured near zero with the OPD-Scan. Conclusion Both devices showed similar level of reproducibility; however, there was considerable difference in the wavefront reading between machines when measuring the same eye. Differences in the number of sample points, centration, and measurement algorithms between the two instruments may explain our results. PMID:17571088
Bernheim, Diane; Rouberol, Frederic; Palombi, Karine; Albrieux, Magali; Romanet, Jean-Paul; Chiquet, Christophe
2013-01-01
To compare the anatomical and functional results of primary rhegmatogenous retinal detachment in highly myopic phakic or pseudophakic eyes. This prospective 2-center study included 191 consecutive eyes (151 phakic and 40 pseudophakic eyes) from a prospective cohort of 835 patients (IRB #5891, between 2004 and 2008). Baseline and follow-up data were systematically recorded at presentation, 1 month, and 6 months or more after surgery. On final examination, two groups were considered based on the need for one or more surgeries to achieve retinal reapplication. End points were primary reattachment rate at the 6-month visit, final anatomical success rate, postoperative visual acuity, and intraoperative and postoperative complications. Pseudophakic eyes differed from phakic eyes in age (60.8 ± 10.4 vs. 49.9 ± 12.3, P < 0.001), smaller pupil dilation (8.0 ± 1.5 vs. 8.5 ± 1.2 mm, P = 0.02), fewer retinal tears seen preoperatively (1.5 ± 1.6 vs. 2.2 ± 2.2, P = 0.06), more frequent use of pars plana vitrectomy (80% vs. 28.5%, P < 0.001), and higher single reattachment rate (92.5% vs. 80.7%). Visual acuity was greater than or equal to 20/40 in 54% of cases with single retinal detachment surgery and 44% of cases with multiple surgeries. Multiple logistic regression analysis showed that only 3 independent variables were significantly predictive of good final visual acuity (20/40): initial visual acuity (<20/400, odds ratio = 0.19; 95% confidence interval, 0.07-0.51; P = 0.002), axial length (odds ratio = 0.57; 95% confidence interval, 0.44-0.75, P < 0.001), and pars plana vitrectomy (odds ratio = 0.33; 95% confidence interval, 0.15-0.71, P = 0.004). This prospective study showed similar baseline retinal detachment characteristics of high myopic phakic or pseudophakic eyes, suggesting that high myopia was the main pathogenic factor in both groups. Although high myopic eye presents anatomical characteristics that could favor surgical morbidity, these recent prospective data show that high myopic eyes exhibit functional and anatomical prognosis close to that described in emmetropic eyes.
Kuhli-Hattenbach, Claudia; Koss, Michael Janusz; Kohnen, Thomas; Fronius, Maria
2015-11-01
To search for morphological abnormalities in compliant unilaterally amblyopic children with poor occlusion treatment outcomes, for the first time with electronically recorded patching dosage. We included school children with remaining interocular logMAR (logarithm of the minimum angle of resolution) difference ≥ 0.3 after patching time of more than 22 months and 1300 h total in a previous prospective study. Six patients with a mean age of 11.19 years were included. Four patients had anisometropic amblyopia and two patients had a mixed strabismic and anisometropic amblyopia. Best-corrected visual acuity, cycloplegic refraction, dilated fundus examination, optic disc morphology and macular thickness using optical coherence tomography (OCT), retinal visual acuity, color perception, and the presence of a relative afferent pupillary defect (RAPD) were assessed. Paired t tests were performed to compare optic disc values and macular thickness of the amblyopic eyes to those of the fellow eyes. Average (± SD) logMAR VA in the amblyopic eyes was 0.42 (±0.23) with a remaining average interocular difference (IOD) of 0.51 (± 0.23), despite electronically monitored occlusion treatment of more than 1300 h. All patients presented with hyperopia and a significantly different mean spherical equivalent of + 4.73 (± 2.73) D in the amblyopic eye compared with the fellow eye (p = 0.02). A statistically significant difference in macular thickness was found between amblyopic and fellow eyes, with amblyopic eyes having an increased average thickness (p = 0.0062) and total volume (p = 0.0091) of the macula. One patient had familial hereditary primary macrodisc in both eyes. Our results provide evidence that average macular thickness and total macular volume tended to be increased among these compliant amblyopic children with unsatisfactory occlusion treatment outcomes. Further studies are warranted to evaluate whether morphological changes may have an impact on the effectiveness of amblyopia treatment. Moreover, our findings suggest that greater magnitude of hyperopia and anisometropia as well as older age may be risk factors associated with a poor visual acuity outcome among compliant amblyopic children.
Turalba, Angela; Payal, Abhishek R; Gonzalez-Gonzalez, Luis A; Cakiner-Egilmez, Tulay; Chomsky, Amy S; Vollman, David E; Baze, Elizabeth F; Lawrence, Mary; Daly, Mary K
2015-10-01
To compare visual acuity outcomes, vision-related quality of life, and complications related to cataract surgery in eyes with and without glaucoma. Retrospective cohort study. Cataract surgery outcomes in cases with and without glaucoma from the Veterans Affairs Ophthalmic Surgical Outcomes Data Project were compared. We identified 608 glaucoma cases and 4306 controls undergoing planned cataract surgery alone. After adjusting for age, pseudoexfoliation, small pupil, prior ocular surgery, and anterior chamber depth, we found that glaucoma cases were more likely to have posterior capsular tear with vitrectomy (odds ratio [OR] 1.8, P = .03) and sulcus intraocular lens placement (OR 1.65, P = .03) during cataract surgery. Glaucoma cases were more likely to have postoperative inflammation (OR 1.73, P < .0001), prolonged elevated intraocular pressure (OR 2.96, P = .0003), and additional surgery within 30 days (OR 1.92, P = .03). Mean best-corrected visual acuity (BCVA) and Visual Function Questionnaire (VFQ) scores significantly improved after cataract surgery in both groups (P < .0001), but there were larger improvements in BCVA (P = .01) and VFQ composite scores (P < .0001) in the nonglaucoma vs the glaucoma group. A total of 3621 nonglaucoma cases (94.1%) had postoperative BCVA 20/40 or better, compared to 466 glaucoma cases (89.6%) (P = .0003). Eyes with glaucoma are at increased risk for complications and have more modest visual outcomes after cataract surgery compared to eyes without glaucoma. Despite this, glaucoma patients still experience significant improvement in vision-related outcomes after cataract extraction. Further study is needed to explore potential factors that influence cataract surgery outcomes in glaucomatous eyes. Published by Elsevier Inc.
Subbiah, Sujata; Thomas, Philip A; Nelson Jesudasan, C A
2017-08-01
To compare data on anatomical and biometric parameters, and their combination, obtained by using ultrasound biomicroscopy (UBM) and A-scan in eyes with phacomorphic glaucoma (PG) and eyes with mature cataract and to determine differences that may predispose to development of PG. Eighty patients (80 eyes) were enrolled in this cross-sectional study. Anterior chamber parameters, namely anterior chamber depth (ACD), angle-opening distance (AOD), iris-lens contact distance (ILCD), and trabecular-ciliary process distance (TCPD), among other parameters, were assessed by UBM (35 MHz), while axial length (AL) and lenticular thickness (LT) were determined by A-scan biometry. Absolute lenticular position (ALP) and relative lenticular position (RLP) were also compared. The mean AL of eyes with PG was less (P = 0.64) than the mean AL of eyes with mature cataract. The mean ILCD value in eyes with PG (1.30 ± 0.78 mm) was significantly higher (P = 0.0015) than that in eyes with mature cataract (0.86 ± 0.32 mm). The mean AOD value in eyes with PG (0.15 ± 0.10 mm) was significantly lower (P < 0.0001) than that in eyes with mature cataract (0.23 ± 0.06 mm); similarly, the mean RLP value in eyes with PG (0.20 ± 0.02) was significantly lower (P < 0.0001) than that in eyes with mature cataract (0.17 ± 0.02). TCPD showed negative correlation with LT r = -0.514; P = 0.017, r 2 = 0.264, in eyes with phacomorphic glaucoma and mature cataracts showed significant negative correlation of ILCD with AL (r = -0.575; P = 0.025, r 2 = 0.330). The results of UBM examination suggest that there are multiple mechanisms underlying the pathophysiology of PG, namely crowding of the anterior segment, increased iris-lens contact distance, and a more pronounced anterior shift of the lens. Simultaneous evaluation of anatomic and biometric parameters can improve diagnostic accuracy in predicting cases at risk for PG.
Acidic mammalian chitinase in dry eye conditions.
Musumeci, Maria; Aragona, Pasquale; Bellin, Milena; Maugeri, Francesco; Rania, Laura; Bucolo, Claudio; Musumeci, Salvatore
2009-07-01
An acidic mammalian chitinase (AMCase) seems to be implicated in allergic asthma and allergic ocular pathologies. The aim of this work was to investigate the role of AMCase during Sjögren's Syndrome (SS) and Meibomian Gland Dysfunction (MGD) dry eye diseases. Six patients with MGD dry eye (20-58 years, median 40) and six patients with dry eye associated to SS (32-60 years, median 47) were enrolled in this study. AMCase activity was measured in tears and AMCase mRNA expression was evaluated by real-time polymerase chain reaction from RNA extracted from epithelial cells of the conjunctiva. Six healthy adult subjects of the same age (34-44 years, median 39) were also studied as the control group. AMCase activity was significantly increased in patients affected by MGD dry eye (18.54 +/- 1.5 nmol/ml/h) and SS dry eye (8.94 +/- 1.0 nmol/ml/h) respectively, compared to healthy controls (1.6 +/- 0.2 nmol/ml/h). AMCase activity was higher in the tears of subjects with MGD dry eye (P < 0.001). AMCase mRNA was detected in conjunctival epithelial cells and the expression was significantly higher in MGD dry eye than SS dry eye. A significant correlation between AMCase activity in the tears and mRNA in conjunctival epithelial cells was found. AMCase may be an important marker in the pathogenesis of dry eye, suggesting the potential role of AMCase as a therapeutic target in these frequent pathologies.
Ueki, Ryotaro; Maeda, Naoyuki; Fuchihata, Mutsumi; Asai, Tomoko; Koh, Shizuka; Fujimoto, Hisataka; Uematsu, Masafumi; Nishida, Kohji
2018-04-26
To investigate the corneal biomechanics in eyes with keratectasia following LASIK using a dynamic Scheimpflug analyzer. Case-Control study. The subjects in the study included 12 eyes with keratectasia after LASIK (KE), 24 eyes with keratoconus (KC), 17 eyes without keratectasia after LASIK (LASIK), and 34 eyes with normal corneas (Normal). Corneal biomechanics of the four groups were evaluated using a dynamic Scheimpflug analyzer. Compared with Normal (7.06 ± 0.54), the radius at the highest concavity (radius, mm) of LASIK (5.96 ± 0.76), KE (4.93 ± 0.61) and KC (5.39 ± 1.02) were significantly small. The Deflection Amplitude (HCDLA, mm) of Normal (0.94 ± 0.07) was significantly lower than those of KE (1.11 ± 0.10) and KC (1.06 ± 0.16), and was not significantly different from that of LASIK (0.98 ± 0.07). There were significant differences between LASIK and KE in radius and HCDLA (P < 0.05), whereas KE and KC had no differences in these parameters. Corneal biomechanical features evaluated using the dynamic Scheimpflug analyzer suggest that biomechanical properties in eyes with keratectasia, keratoconus, and LASIK are different from those of normal eyes. Although the biomechanics in eyes with keratectasia differs from that in eyes with LASIK, it is similar to that in eyes with keratoconus.
Functional visual acuity in patients with successfully treated amblyopia: a pilot study.
Hoshi, Sujin; Hiraoka, Takahiro; Kotsuka, Junko; Sato, Yumiko; Izumida, Shinya; Kato, Atsuko; Ueno, Yuta; Fukuda, Shinichi; Oshika, Tetsuro
2017-06-01
The aim of this study was to use conventional visual acuity measurements to quantify the functional visual acuity (FVA) in eyes with successfully treated amblyopia, and to compare the findings with those for contralateral normal eyes. Nineteen patients (7 boys, 12 girls; age 7.5 ± 2.2 years) with successfully treated unilateral amblyopia and the same conventional decimal visual acuity in both eyes (better than 1.0) were enrolled. FVA, the visual maintenance ratio (VMR), maximum and minimum visual acuity, and the average response time were recorded for both eyes of all patients using an FVA measurement system. The differences in FVA values between eyes were analyzed. The mean LogMAR FVA scores, VMR (p < 0.001 for both), and the LogMAR maximum (p < 0.005) and minimum visual acuity (p < 0.001) were significantly poorer for the eyes with treated amblyopia than for the contralateral normal eyes. There was no significant difference in the average response time. Our results indicate that FVA and VMR were poorer for eyes with treated amblyopia than for normal eyes, even though the treatment for amblyopia was considered successful on the basis of conventional visual acuity measurements. These results suggest that visual function is impaired in eyes with amblyopia, regardless of treatment success, and that FVA measurements can provide highly valuable diagnosis and treatment information that is not readily provided by conventional visual acuity measurements.
Cekiç, Osman; Bardak, Yavuz; Tiğ, Sahin U; Demirkol, Aykut; Ekim, Mustafa M; Altintaş, Onem; Yeşildağ, Ahmet; Oyar, Orhan
2007-10-01
To assess ocular hemodynamic response to intravitreal triamcinolone in patients with macular edema due to diabetes or retinal vein occlusion. Forty-three patients that were injected by intravitreal triamcinolone acetonide (0.1 cc 4 mg) for unilateral macular edema due to diabetes mellitus (n = 17) and occlusion of retinal vein (n = 26) underwent ocular hemodynamic evaluation by color Doppler imaging (CDI) before and one, two and three months after injection. Non-injected fellow eyes as well as 16 healthy volunteers were also evaluated. In patients with diabetic macular edema, there was no hemodynamic difference between eyes to be injected and non-injected at baseline (P > 0.23). Compared to controls, a significant difference existed in the ophthalmic artery resistant index (P = 0.001) and end-diastolic velocity (P < 0.001) in diabetics. At one month, compared to fellow eyes, change in end diastolic velocity from baseline in treated eyes was significantly decreased in posterior ciliary arteries (0.68 +/- 0.34 cm/s [mean +/- SEM] vs. -1.04 +/- 0.81 cm/s, P = 0.012). Throughout the study period, no significant alteration from baseline in the resistant index of any artery was noted in treated diabetic eyes (P > 0.05). In eyes with retinal vein occlusion, baseline CDI evaluation demonstrated reduced posterior ciliary arteries systolic flow velocity compared to fellow and control eyes (13.24 +/- 1.04 cm/s, 16.37 +/- 0.76 cm/s and 14.33 +/- 1.41 cm/s, respectively, P = 0.007). Increased peak systolic velocity in the posterior ciliary arteries at one week (P = 0.02), one month (P = 0.005) and two months (P = 0.04), and increase in central retinal artery resistant index at one month was noted (P = 0.05). Intravitreal triamcinolone temporarily changed central retinal artery blood flow and posterior ciliary arteries' peak systolic blood velocity in eyes with retinal vein occlusion whilst no response of blood flow to triamcinolone injection but only transiently altered end diastolic blood velocity in posterior ciliary arteries was observed in diabetic eyes.
Risk factors for retinal breaks in patients with symptom of floaters.
Singalavanija, Apichart; Amornrattanapan, Chutiwan; Nitiruangjarus, Kanjanee; Tongsai, Sasima
2010-06-01
To identify the risk factors of retinal breaks in patients with the symptom of floaters, and to determine the association between those risk factors and retinal breaks. A retrospective analytic study of 184 patients (55 males and 129 females) that included 220 eyes was conducted. Patient information such as age, symptoms (multiple floaters, flashing), duration of symptom, refractive error, history of cataract surgery, family history of retinal detachment, and complete eye examination were recorded. The patients were divided into two groups, the first group (control group) had symptoms of floaters and no retinal breaks, the second group (retinal breaks group) had symptoms of floaters with retinal breaks. Chi-square test, and the multiple logistic regression were used for statistical analysis. Two hundred twenty eyes, 175 eyes of the control group and 45 eyes of the retinal breaks group were examined and included in this study. The multiple logistic regression analysis revealed that patients with multiple floaters, and floaters and flashing increased the risk of retinal breaks to 5.8 and 4.3 times, respectively, when compared to patients with single floater or floaters alone. Lattice degeneration increased the risk of retinal breaks to 5.9 times when compared to eyes that did not have lattice degeneration. Multiple floaters, flashing and lattice degeneration are risk factors of retinal breaks in patients with symptoms of floaters. Therefore, it is important for the ophthalmologists to be aware of these risk factors and the patients at risk should have follow-up examinations.
Radioprotective effect of a metalloporphyrin compound in rat eye model.
Mao, X W; Crapo, J D; Mekonnen, T; Lindsey, N; Martinez, P; Gridley, D S; Slater, J M
2009-01-01
The purpose of this study was to evaluate the efficacy of the antioxidant Mn (III) tetrakis (N-ethylpyridinium-2-yl) porphyrin (MnTE-2-PyP) in protecting ocular tissue and retinal microvasculature from radiation damage. 75 rats were treated with Mn TE-2-PyP at 2.5 micro g/injection into one eye an hour before proton irradiation. The radiation was delivered in a single fraction to total doses of 8 Gray (Gy) or 28 Gy; Rats were sacrificed 3 days and 3, 6, 9, and 12 months thereafter for histology and quantification of photoreceptor cell populations and retinal capillary changes. By 6 months following radiation, there was significant loss of retinal outer and inner nuclear layers in eyes receiving radiation only (8 and 28 Gy) (p < 0.05) compared to their controls and to the eyes of rats treated with radiation plus metalloporphyrin. Retinal microvessel length density decreased significantly 6 months following 28 Gy (p < 0.05) compared to their controls and to MnTE-2-PyP treated rats. By 12 months following irradiation, irradiated eyes showed extensive damage to the photoreceptor layer, whereas the eyes of animals receiving radiation plus MnTE-2-PyP showed almost no morphological damage. MnTE-2-PyP treatment also suppressed radiation-induced apoptosis in our study. These results demonstrated that MnTE-2-PyP protected both photoreceptors and retinal capillaries from radiation damage, suggesting that this metalloporphyrin antioxidant is effective in regulating the damage induced by proton radiation.
Dry eyes and AIs: If you don't ask you won't find out.
Inglis, Holly; Boyle, Frances M; Friedlander, Michael L; Watson, Stephanie L
2015-12-01
Our objective was to investigate the hypothesis that women on adjuvant aromatase inhibitors (AIs) for treatment of breast cancer have a higher prevalence of dry eye syndrome (DES) compared with controls. Exposure and control groups were recruited. A cross sectional questionnaire-based study was performed. Demographic data and medical histories were collected. The presence of dry eye syndrome was determined by the ocular surface disease index (OSDI). The Functional Assessment of Cancer Treatment - Endocrine Subscale (FACT-ES) was performed to investigate correlations with other side effects of AIs. 93 exposure group and 100 control group questionnaires were included. The groups were similar in all demographic variables. The prevalence of dry eye syndrome was 35% (exposure) and 18% (control) (p < 0.01, OR 2.5). AIs were the only factor associated with dry eyes. The OSDI score was negatively correlated with the total FACT-ES score and positively correlated with duration of treatment. Our study is the first to use a validated questionnaire to assess for DES in this population. DES is significantly more prevalent in women on AIs compared with controls. This is a newly emerging, and easily treated side effect of AIs. Self-reporting of dry eye symptoms underestimates the prevalence of DES with AIs. We recommend routine screening of patients on AIs with the OSDI with the aim of improving patient quality of life and possibly adherence. Copyright © 2015 Elsevier Ltd. All rights reserved.
Altered characteristics of balance control in obese older adults.
Melzer, Itshak; Oddsson, Lars I E
2016-01-01
Obesity is one of the most significant epidemiological trends of the last decades. Recently it was found that obese individuals show postural instability. Balance control mechanisms in obese older adults were less studied. Therefore we aimed to investigate the effect of obesity on balance control mechanisms in older adults. Parameters from Stabilogram-Diffusion Analysis (SDA) and measures from summary statistics of foot centre-of-pressure (COP) displacements along the anterior-posterior (AP) and mediolateral (ML) directions in eyes open and eyes closed conditions were used to characterize postural control in 22 obese (30-<35kg/m(2)), 26 overweight (25-<30kg/m(2)), and 18 normal weight subjects (18.5-<25kg/m(2)). Obese group subjects demonstrated significantly greater transition displacement, transition time interval, and short-term scaling exponent in the ML-direction compared with the normal weight group (eyes open and closed). In the AP-direction the obese group showed greater transition displacement (eyes open) and short-term scaling exponent (eyes open and closed). Average AP-COP and ML-COP ranges of COP sway were higher in the obese group compared with the normal weight group (eyes open and closed). This work indicates an altered postural control process in obese older adults. A greater sway displacement before closed-loop feedback mechanisms are called into play was seen in the ML direction that may lead to a higher risk of instability and fall events. Copyright © 2015 Asia Oceania Association for the Study of Obesity. Published by Elsevier Ltd. All rights reserved.
Air-gas exchange reevaluated: clinically important results of a computer simulation.
Shunmugam, Manoharan; Shunmugam, Sudhakaran; Williamson, Tom H; Laidlaw, D Alistair
2011-10-21
The primary aim of this study was to evaluate the efficiency of air-gas exchange techniques and the factors that influence the final concentration of an intraocular gas tamponade. Parameters were varied to find the optimum method of performing an air-gas exchange in ideal circumstances. A computer model of the eye was designed using 3D software with fluid flow analysis capabilities. Factors such as angular distance between ports, gas infusion gauge, exhaust vent gauge and depth were varied in the model. Flow rate and axial length were also modulated to simulate faster injections and more myopic eyes, respectively. The flush volume of gas required to achieve a 97% intraocular gas fraction concentration were compared. Modulating individual factors did not reveal any clinically significant difference in the angular distance between ports, exhaust vent size, and depth or rate of gas injection. In combination, however, there was a 28% increase in air-gas exchange efficiency comparing the most efficient with the least efficient studied parameters in this model. The gas flush volume required to achieve a 97% gas fill also increased proportionately at a ratio of 5.5 to 6.2 times the volume of the eye. A 35-mL flush is adequate for eyes up to 25 mm in axial length; however, eyes longer than this would require a much greater flush volume, and surgeons should consider using two separate 50-mL gas syringes to ensure optimal gas concentration for eyes greater than 25 mm in axial length.
Wu, Chun-jie; Huang, Qin-wan; Qi, Hong-yi; Guo, Ping; Hou, Shi-xiang
2006-09-01
Studies on the influence of borneol on the penetration of puerarin eye drops and timolol maleate eye drops through the cornea, and evaluation of the ocular irritability were conducted to provide a theoretical basis for the application of borneol in enhancing corneal permeability. The cornea penetrative experiment in vitro was conducted to observe the quantitative change of puerarin and timolol maleate penetrated through the cornea after administering different dosages of borneol. The corneal hydration level and blinking frequency were recorded as irritability indexes in vitro and in vivo. The steady-flow J of high, middle and low dosage groups of puerarin eye drops with borneol were increased by 49%, 32%, 5% respectively, and permeability parameter Kp increased by 49%, 32%, 5% respectively, as compared to that of the control group. The steady-flow J of high dosage group of timolol maleate eye drops with borneol was increased by 5%; middle and low dosage groups with borneol were decreased by 6%, 3% respectively. The permeability parameter Kp of high dosage group increased by 5%, while middle and low dosage groups with borneol were decreased by 6%, 3% respectively, as compared to that of the control group. Evaluation showed no ocular irritability caused by borneol. The results of this study suggest that the promoting effect of borneol on the permeability of drugs through the cornea in vitro is selective, which indicates that borneol has the potential to be used as an ophthalmic penetration enhancer.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Asadi, Somayeh; Masoudi, Seyed Farhad, E-mail: masoudi@kntu.ac.ir; Shahriari, Majid
In ophthalmic brachytherapy dosimetry, it is common to consider the water phantom as human eye anatomy. However, for better clinical analysis, there is a need for the dose determination in different parts of the eye. In this work, a full human eye is simulated with MCNP-4C code by considering all parts of the eye, i.e., the lens, cornea, retina, choroid, sclera, anterior chamber, optic nerve, and bulk of the eye comprising vitreous body and tumor. The average dose in different parts of this full model of the human eye is determined and the results are compared with the dose calculatedmore » in water phantom. The central axes depth dose and the dose in whole of the tumor for these 2 simulated eye models are calculated as well, and the results are compared.« less
Recent clinically relevant highlights from the Diabetic Retinopathy Clinical Research Network.
Krick, Tracy W; Bressler, Neil M
2018-05-01
To present some recent clinically relevant results from Diabetic Retinopathy Clinical Research (DRCR) Network trials that may guide management of diabetic macular edema (DME) or proliferative diabetic retinopathy (PDR). Among eyes with DME and visual acuity 20/50 or worse, aflibercept, on average, had greater improvement in visual acuity over 2 years compared with bevacizumab or ranibizumab. Aflibercept is associated with higher rates of improvements in diabetic retinopathy severity among eyes with PDR and vision-impairing DME at baseline compared with bevacizumab or ranibizumab. Among eyes with persistent central-involved DME after at least six antivascular endothelial growth factor (anti-VEGF) injections, no difference in mean visual acuity improvement was observed between eyes that received continued ranibizumab and sham injections versus ranibizumab and intravitreous sustained dexamethasone drug-delivery system, especially for phakic eyes. For eyes with PDR, ranibizumab was associated with lower rates of developing PDR-worsening events compared with panretinal photocoagulation, especially among eyes that did not receive ranibizumab for central-involved DME at baseline. Ranibizumab is cost-effective for PDR for eyes with, not without, vision-impairing central-involved DME, highlighting challenges when safety and efficacy results are at odds with cost-effectiveness results. Aflibercept for DME, in certain circumstances, is more likely to have superior visual acuity and anatomical outcomes compared with bevacizumab or ranibizumab. No vision benefits are apparent, especially for phakic eyes, by adding intravitreous corticosteroids for persistent DME following anti-VEGF injections.
Javorkova, Eliska; Trosan, Peter; Zajicova, Alena; Krulova, Magdalena; Hajkova, Michaela
2014-01-01
The aim of this study was to investigate the effects of systemically administered bone-marrow-derived mesenchymal stromal cells (MSCs) on the early acute phase of inflammation in the alkali-burned eye. Mice with damaged eyes were either untreated or treated 24 h after the injury with an intravenous administration of fluorescent-dye-labeled MSCs that were unstimulated or pretreated with interleukin-1α (IL-1α), transforming growth factor-β (TGF-β), or interferon-γ (IFN-γ). Analysis of cell suspensions prepared from the eyes of treated mice on day 3 after the alkali burn revealed that MSCs specifically migrated to the damaged eye and that the number of labeled MSCs was more than 30-times higher in damaged eyes compared with control eyes. The study of the composition of the leukocyte populations within the damaged eyes showed that all types of tested MSCs slightly decreased the number of infiltrating lymphoid and myeloid cells, but only MSCs pretreated with IFN-γ significantly decreased the percentage of eye-infiltrating cells with a more profound effect on myeloid cells. Determining cytokine and NO production in the damaged eyes confirmed that the most effective immunomodulation was achieved with MSCs pretreated with IFN-γ, which significantly decreased the levels of the proinflammatory molecules IL-1α, IL-6, and NO. Taken together, the results show that systemically administered MSCs specifically migrate to the damaged eye and that IFN-γ-pretreated MSCs are superior in inhibiting the acute phase of inflammation, decreasing leukocyte infiltration, and attenuating the early inflammatory environment. PMID:24849741
Grating visual acuity results in the early treatment for retinopathy of prematurity study.
Dobson, Velma; Quinn, Graham E; Summers, C Gail; Hardy, Robert J; Tung, Betty; Good, William V
2011-07-01
To compare grating (resolution) visual acuity at 6 years of age in eyes that received early treatment (ET) for high-risk prethreshold retinopathy of prematurity (ROP) with that in eyes that underwent conventional management (CM). In a randomized clinical trial, infants with bilateral, high-risk prethreshold ROP (n = 317) had one eye undergo ET and the other eye undergo CM, with treatment only if ROP progressed to threshold severity. For asymmetric cases (n = 84), the high-risk prethreshold eye was randomized to ET or CM. Grating visual acuity measured at 6 years of age by masked testers using Teller acuity cards. Monocular grating acuity results were obtained from 317 of 370 surviving children (85.6%). Analysis of grating acuity results for all study participants with high-risk prethreshold ROP showed no statistically significant overall benefit of ET (18.1% vs 22.8% unfavorable outcomes; P = .08). When the 6-year grating acuity results were analyzed according to a clinical algorithm (high-risk types 1 and 2 prethreshold ROP), a benefit was seen in type 1 eyes (16.4% vs 25.2%; P = .004) undergoing ET, but not in type 2 eyes (21.3% vs 15.9%; P = .29). Early treatment of eyes with type 1 ROP improves grating acuity outcomes, but ET for eyes with type 2 ROP does not. APPLICATION TO CLINICAL MEDICINE: Type 1 eyes should be treated early; however, based on acuity results at 6 years of age, type 2 eyes should be cautiously monitored for progression to type 1 ROP. Trial Registration clinicaltrials.gov Identifier: NCT00027222.
Efficacy of Intracameral Moxifloxacin Endophthalmitis Prophylaxis at Aravind Eye Hospital.
Haripriya, Aravind; Chang, David F; Namburar, Sathvik; Smita, Anand; Ravindran, Ravilla D
2016-02-01
To compare the rate of postoperative endophthalmitis before and after initiation of intracameral (IC) moxifloxacin for endophthalmitis prophylaxis in patients undergoing cataract surgery. Retrospective, clinical registry. All charity and private patients (116 714 eyes) who underwent cataract surgery between February 15, 2014, and April 15, 2015, at the Madurai Aravind Eye Hospital were included. Group 1 consisted of 37 777 eyes of charity patients who did not receive IC moxifloxacin, group 2 consisted of 38 160 eyes of charity patients who received IC moxifloxacin prophylaxis, and group 3 consisted of 40 777 eyes of private patients who did not receive IC moxifloxacin. The electronic health record data for each of the 3 groups were analyzed, and the postoperative endophthalmitis rates were statistically compared. The cost of endophthalmitis treatment (groups 1 and 2) and the cost of IC moxifloxacin prophylaxis (group 2) were calculated. Postoperative endophthalmitis rate before and after initiation of IC moxifloxacin endophthalmitis treatment cost. Manual, sutureless, small incision cataract surgery (M-SICS) accounted for approximately all of the 75 937 cataract surgeries in the charity population (97%), but only a minority of the 40 777 private surgeries (21% M-SICS; 79% phacoemulsification). Thirty eyes in group 1 (0.08%) and 6 eyes in group 2 (0.02%) were diagnosed with postoperative endophthalmitis (P < 0.0001). The group 3 endophthalmitis rate was 0.07% (29 eyes), which was also higher than the second group's rate (P < 0.0001). There were no adverse events attributed to IC moxifloxacin in group 2. The total cost of treating the 30 patients with endophthalmitis in group 1 was virtually identical to the total combined cost in group 2 of routine IC moxifloxacin prophylaxis and treatment of the 6 endophthalmitis cases. Routine IC moxifloxacin prophylaxis achieved a highly significant, 4-fold reduction in postoperative endophthalmitis in patients undergoing M-SICS. Compared with previous studies, having such a high volume of patients undergoing surgery during a relatively short 14-month time period strengthens the conclusion. This study provides further evidence that moxifloxacin is an effective IC prophylactic antibiotic and suggests that IC antibiotics should be considered for M-SICS and phacoemulsification. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Atchison, Elizabeth A; Wood, Kevin M; Mattox, Cynthia G; Barry, Catherine N; Lum, Flora; MacCumber, Mathew W
2018-05-01
To identify sustained differences in intraocular pressure (IOP) after intravitreous injections of anti-vascular endothelial growth factor (VEGF) drugs. Database study. Patients seeing an ophthalmic provider who contributes to the database. We identified a total of 23 776 unique patients who received only a single type of anti-VEGF medication (bevacizumab, aflibercept, or ranibizumab) by injection in the right eye in the American Academy of Ophthalmology Intelligent Research in Sight Registry. Subgroups included patients with age-related macular degeneration only and patients who had not received an anti-VEGF injection for at least 1 year before the study. We examined those with at least 12, 18, and 25 injections for each of these 3 medications. For all groups, we used fellow, untreated eyes for comparison. The mean change in IOP from baseline at a minimum of 1 year of follow-up and the proportion of eyes with a clinically significant IOP increase (defined as sustained rise of at least 6 mmHg to an IOP of more than 21 mmHg). All patients in all groups receiving all drugs showed a decrease in IOP from baseline, with a mean of 0.9 mmHg in treated eyes compared with an average decrease of 0.2 mmHg in fellow untreated eyes, a statistically significant difference. A generalized linear model accounting for confounders associated bevacizumab with slightly less lowering of IOP than aflibercept and ranibizumab in most subgroups. A clinically significant IOP increase was seen in 2.6% of eyes receiving injections compared with 1.5% in the associated untreated fellow eyes. Clinically significant IOP increases occurred at a rate of 1.9%, 2.8%, and 2.8% for aflibercept, ranibizumab, and bevacizumab, respectively, which was significantly higher than untreated fellow eyes for bevacizumab and ranibizumab, but not for aflibercept. These analyses from real-world data indicate that anti-VEGF intravitreous injections are associated with a small but statistically significant decrease in IOP over time. A proportion of patients, on average 2.6%, experienced a sustained clinically significant IOP rise with these drugs overall compared with 1.5% in the fellow untreated eyes. However, such an increase was not seen with aflibercept. Copyright © 2018 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Eye-hand coordination during a double-step task: evidence for a common stochastic accumulator
Gopal, Atul
2015-01-01
Many studies of reaching and pointing have shown significant spatial and temporal correlations between eye and hand movements. Nevertheless, it remains unclear whether these correlations are incidental, arising from common inputs (independent model); whether these correlations represent an interaction between otherwise independent eye and hand systems (interactive model); or whether these correlations arise from a single dedicated eye-hand system (common command model). Subjects were instructed to redirect gaze and pointing movements in a double-step task in an attempt to decouple eye-hand movements and causally distinguish between the three architectures. We used a drift-diffusion framework in the context of a race model, which has been previously used to explain redirect behavior for eye and hand movements separately, to predict the pattern of eye-hand decoupling. We found that the common command architecture could best explain the observed frequency of different eye and hand response patterns to the target step. A common stochastic accumulator for eye-hand coordination also predicts comparable variances, despite significant difference in the means of the eye and hand reaction time (RT) distributions, which we tested. Consistent with this prediction, we observed that the variances of the eye and hand RTs were similar, despite much larger hand RTs (∼90 ms). Moreover, changes in mean eye RTs, which also increased eye RT variance, produced a similar increase in mean and variance of the associated hand RT. Taken together, these data suggest that a dedicated circuit underlies coordinated eye-hand planning. PMID:26084906
Speer, Colenso M; Sun, Chao; Liets, Lauren C; Stafford, Ben K; Chapman, Barbara; Cheng, Hwai-Jong
2014-11-07
Spontaneous retinal activity (SRA) is important during eye-specific segregation within the dorsal lateral geniculate nucleus (dLGN), but the feature(s) of activity critical for retinogeniculate refinement are controversial. Pharmacologically or genetically manipulating cholinergic signaling during SRA perturbs correlated retinal ganglion cell (RGC) spiking and disrupts eye-specific retinofugal refinement in vivo, consistent with an instructive role for SRA during visual system development. Paradoxically, ablating the starburst amacrine cells (SACs) that generate cholinergic spontaneous activity disrupts correlated RGC firing without impacting retinal activity levels or eye-specific segregation in the dLGN. Such experiments suggest that patterned SRA during retinal waves is not critical for eye-specific refinement and instead, normal activity levels are permissive for retinogeniculate development. Here we revisit the effects of ablating the cholinergic network during eye-specific segregation and show that SAC ablation disrupts, but does not eliminate, retinal waves with no concomitant impact on normal eye-specific segregation in the dLGN. We induced SAC ablation in postnatal ferret pups beginning at birth by intraocular injection of a novel immunotoxin selective for the ferret vesicular acetylcholine transporter (Ferret VAChT-Sap). Through dual-patch whole-cell and multi-electrode array recording we found that SAC ablation altered SRA patterns and led to significantly smaller retinal waves compared with controls. Despite these defects, eye-specific segregation was normal. Further, interocular competition for target territory in the dLGN proceeded in cases where SAC ablation was asymmetric in the two eyes. Our data demonstrate normal eye-specific retinogeniculate development despite significant abnormalities in patterned SRA. Comparing our current results with earlier studies suggests that defects in retinal wave size, absolute levels of SRA, correlations between RGC pairs, RGC burst frequency, high frequency RGC firing during bursts, and the number of spikes per RGC burst are each uncorrelated with abnormalities in eye-specific segregation in the dLGN. An increase in the fraction of asynchronous spikes occurring outside of bursts and waves correlates with eye-specific segregation defects in studies reported to date. These findings highlight the relative importance of different features of SRA while providing additional constraints for computational models of Hebbian plasticity mechanisms in the developing visual system.
Ultra-widefield fluorescein angiography of white without pressure
Orlin, Anton; Fatoo, Aalya; Ehrlich, Joshua; D’Amico, Donald J; Chan, RV Paul; Kiss, Szilárd
2013-01-01
Purpose To describe ultra-widefield fluorescein angiography (UWFA) findings in eyes with white without pressure (WWOP) and in eyes without any obvious peripheral chorioretinal disease, and to determine if a difference exists between these two groups. Methods A retrospective review of 379 eyes undergoing diagnostic UWFA using the Optos 200Tx imaging system. Eyes were excluded if the quality of the color photograph or UWFA prevented reliable evaluation. Eyes were also excluded if there was any evidence of peripheral retinal or choroidal disease, which was thought to have an effect on UWFA (eg, peripheral background diabetic or hypertensive retinopathy, vein occlusion, or any other peripheral vascular disorder). Eyes were determined to have WWOP, based on a dilated fundus examination and color fundus photography that contained areas of peripheral retinal whitening consistent with the diagnosis. UWFA was evaluated by trained masked graders, and determined to have or not have peripheral vascular leakage and/or staining. Results Of the 379 eyes evaluated, 45 eyes were included in the study. Twelve eyes were determined to have peripheral WWOP; 33 eyes did not have WWOP on examination or color fundus photography. Three common UWFA peripheral patterns were visualized. Eyes with and without WWOP were grouped into one of three patterns. The majority of eyes without WWOP demonstrated UWFA pattern one (69.7%), while those in the WWOP group demonstrated pattern three (50%). The distribution of UWFA patterns is statistically different between those with and without WWOP (P = 0.002). In eyes without WWOP, in patients with no documented systemic microvascular disease (diabetes, hypertension), 71.4% of eyes had UWFA pattern one while 14.3% had both patterns two and three. Conclusion This study is one of the first to specifically evaluate peripheral vascular leakage/staining in eyes with WWOP as well as in eyes without any obvious peripheral chorioretinal disease. We demonstrate that a significant portion of WWOP eyes exhibit peripheral findings on UWFA (pattern one) compared to eyes without WWOP. Importantly, even in eyes that are apparently unremarkable in the periphery on exam and color photography, UWFA can still show peripheral vascular abnormalities. These results warrant further investigation. PMID:23737658
Early light deprivation effects on human cone-driven retinal function.
Esposito Veneruso, Paolo; Ziccardi, Lucia; Magli, Giulia; Parisi, Vincenzo; Falsini, Benedetto; Magli, Adriano
2017-03-01
To assess whether the early light deprivation induced by congenital cataract may influence the cone-driven retinal function in humans. Forty-one patients affected by congenital cataract (CC) who had undergone uncomplicated cataract extraction surgery and intraocular lens implant, and 14 healthy subjects (HS) were enrolled. All patients underwent complete ophthalmological and orthoptic evaluations and best-corrected visual acuity (BCVA) measurement; light-adapted full-field electroretinograms (ERG) and photopic negative responses (PhNR) were recorded to obtain a reliable measurement of the outer/inner retinal function and of the retinal ganglion cells' function respectively. Mean values of light-adapted ERG a- and b-wave and PhNR amplitude of CC eyes were significantly reduced and photopic ERG b-wave implicit time mean values were significantly delayed when compared to HS ones. When studying photopic ERG mean amplitudes at 5 ms, significant differences were found when comparing CC and control eyes. In CC eyes, statistically significant correlations were found between a- and b- wave amplitudes and PhNR amplitudes. No significant correlations were found between ERG parameters and BCVA, as well as between the age of CC patients at surgery and the time elapsed from lens extraction. No significant differences were found when functional parameters of bilateral and unilateral congenital cataract (uCC) eyes were compared, however uCC eyes showed significant differences when compared with contralateral healthy eyes. We found a significant impairment of cone-driven retinal responses in patients with a history of congenital cataract. These changes might result from the long-lasting effects of early light deprivation on the cone retinal pathways. Our findings support the relevance of retinal involvement in deficits induced by early light deprivation. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Kelly, Brendan S; Rainford, Louise A; Darcy, Sarah P; Kavanagh, Eoin C; Toomey, Rachel J
2016-07-01
Purpose To investigate the development of chest radiograph interpretation skill through medical training by measuring both diagnostic accuracy and eye movements during visual search. Materials and Methods An institutional exemption from full ethical review was granted for the study. Five consultant radiologists were deemed the reference expert group, and four radiology registrars, five senior house officers (SHOs), and six interns formed four clinician groups. Participants were shown 30 chest radiographs, 14 of which had a pneumothorax, and were asked to give their level of confidence as to whether a pneumothorax was present. Receiver operating characteristic (ROC) curve analysis was carried out on diagnostic decisions. Eye movements were recorded with a Tobii TX300 (Tobii Technology, Stockholm, Sweden) eye tracker. Four eye-tracking metrics were analyzed. Variables were compared to identify any differences between groups. All data were compared by using the Friedman nonparametric method. Results The average area under the ROC curve for the groups increased with experience (0.947 for consultants, 0.792 for registrars, 0.693 for SHOs, and 0.659 for interns; P = .009). A significant difference in diagnostic accuracy was found between consultants and registrars (P = .046). All four eye-tracking metrics decreased with experience, and there were significant differences between registrars and SHOs. Total reading time decreased with experience; it was significantly lower for registrars compared with SHOs (P = .046) and for SHOs compared with interns (P = .025). Conclusion Chest radiograph interpretation skill increased with experience, both in terms of diagnostic accuracy and visual search. The observed level of experience at which there was a significant difference was higher for diagnostic accuracy than for eye-tracking metrics. (©) RSNA, 2016 Online supplemental material is available for this article.
Kernt, Marcus; Hadi, Indrawati; Pinter, Florian; Seidensticker, Florian; Hirneiss, Christoph; Haritoglou, Christos; Kampik, Anselm; Ulbig, Michael W.; Neubauer, Aljoscha S.
2012-01-01
OBJECTIVE To compare the diagnostic properties of a nonmydriatic 200° ultra-widefield scanning laser ophthalmoscope (SLO) versus mydriatic Early Treatment of Diabetic Retinopathy Study (ETDRS) 7-field photography for diabetic retinopathy (DR) screening. RESEARCH DESIGN AND METHODS A consecutive series of 212 eyes of 141 patients with different levels of DR were examined. Grading of DR and clinically significant macular edema (CSME) from mydriatic ETDRS 7-field stereo photography was compared with grading obtained by Optomap Panoramic 200 SLO images. All SLO scans were performed through an undilated pupil, and no additional clinical information was used for evaluation of all images by the two independent, masked, expert graders. RESULTS Twenty-two eyes from ETDRS 7-field photography and 12 eyes from Optomap were not gradable by at least one grader because of poor image quality. A total of 144 eyes were analyzed regarding DR level and 155 eyes regarding CSME. For ETDRS 7-field photography, 22 eyes (18 for grader 2) had no or mild DR (ETDRS levels ≤ 20) and 117 eyes (111 for grader 2) had no CSME. A highly substantial agreement between both Optomap DR and CSME grading and ETDRS 7-field photography existed with κ = 0.79 for DR and 0.73 for CSME for grader 1, and κ = 0.77 (DR) and 0.77 (CSME) for grader 2. CONCLUSIONS Determination of CSME and grading of DR level from Optomap Panoramic 200 nonmydriatic images show a positive correlation with mydriatic ETDRS 7-field stereo photography. Both techniques are of sufficient quality to assess DR and CSME. Optomap Panoramic 200 images cover a larger retinal area and therefore may offer additional diagnostic properties. PMID:22912430
Kernt, Marcus; Hadi, Indrawati; Pinter, Florian; Seidensticker, Florian; Hirneiss, Christoph; Haritoglou, Christos; Kampik, Anselm; Ulbig, Michael W; Neubauer, Aljoscha S
2012-12-01
To compare the diagnostic properties of a nonmydriatic 200° ultra-widefield scanning laser ophthalmoscope (SLO) versus mydriatic Early Treatment of Diabetic Retinopathy Study (ETDRS) 7-field photography for diabetic retinopathy (DR) screening. A consecutive series of 212 eyes of 141 patients with different levels of DR were examined. Grading of DR and clinically significant macular edema (CSME) from mydriatic ETDRS 7-field stereo photography was compared with grading obtained by Optomap Panoramic 200 SLO images. All SLO scans were performed through an undilated pupil, and no additional clinical information was used for evaluation of all images by the two independent, masked, expert graders. Twenty-two eyes from ETDRS 7-field photography and 12 eyes from Optomap were not gradable by at least one grader because of poor image quality. A total of 144 eyes were analyzed regarding DR level and 155 eyes regarding CSME. For ETDRS 7-field photography, 22 eyes (18 for grader 2) had no or mild DR (ETDRS levels ≤ 20) and 117 eyes (111 for grader 2) had no CSME. A highly substantial agreement between both Optomap DR and CSME grading and ETDRS 7-field photography existed with κ = 0.79 for DR and 0.73 for CSME for grader 1, and κ = 0.77 (DR) and 0.77 (CSME) for grader 2. Determination of CSME and grading of DR level from Optomap Panoramic 200 nonmydriatic images show a positive correlation with mydriatic ETDRS 7-field stereo photography. Both techniques are of sufficient quality to assess DR and CSME. Optomap Panoramic 200 images cover a larger retinal area and therefore may offer additional diagnostic properties.
Alfawaz, Abdullah M; Algehedan, Saeed; Jastaneiah, Sabah S; Al-Mansouri, Samir; Mousa, Ahmed; Al-Assiri, Abdullah
2014-03-01
To evaluate the effect of punctal plug use in preventing dry eye after laser in situ keratomileusis (LASIK). A randomized clinical trial at a tertiary eye care center, Riyadh, Saudi Arabia. Participants underwent LASIK for myopia in both eyes and a lower punctal occlusion in one eye only while the other eye served as control. Both eyes received the same postoperative medications except for lubricant duration (subject eye: four times per day for one week; control eye: four times per day for 6 months). Participants were evaluated at 1 week, 2, and 6 months after surgery for signs and symptoms of dry eye. The main outcome measures were visual acuity; ocular surface parameters; and Ocular Surface Disease Index questionnaire. Seventy-eight eyes of 39 patients were included in this study. The Ocular Surface Disease Index scores of eyes with punctal plugs were better at all follow-up visits, and the differences between both eyes were statistically significant (1 week, p < 0.0001; 2 months, p < 0.0001; 6 months, p = 0.008). At the final follow-up visit, the percentage of normal eyes was higher in eyes with punctal plugs for all ocular surface parameters (Schirmer 1 test, 94.9%; tear breakup time, 77.8%; punctate epithelial keratitis score, 71.8%) compared to eyes without occlusion (Schirmer 1 test, 92.3%; tear breakup time, 58.3%; punctate epithelial keratitis score, 53.8%); however, such differences were not statistically significant. Punctal plug insertion after LASIK surgeries may minimize the need for frequent lubricant application and hence improve patient satisfaction.
Vision loss among diabetics in a group model Health Maintenance Organization (HMO).
Fong, Donald S; Sharza, Mohktar; Chen, Wansu; Paschal, John F; Ariyasu, Reginald G; Lee, Paul P
2002-02-01
To report the management of diabetic retinopathy in one group model health maintenance organization and assess the quality of care. Cross-sectional study. A chart review of 1200 randomly identified patients with diabetes mellitus, continuously enrolled for 3 years in Kaiser Permanente (KP) Southern California, the largest provider of managed care in Southern California, was performed. A total of 1047 patients were included in the analyses. Patient characteristics as well as information from the last eye examination were abstracted. Charts from patients with visual acuity less than 20/200 in their better eye (legal blindness) were selected for extensive chart review to determine the cause of visual loss and the antecedent process of care. T tests or the Wilcoxon rank sum test was used to compare continuous variables. The chi(2) test or the Fisher exact test was used to compare categorical variables. All analyses were performed on the Statistical Analyses System (SAS Institute, North Carolina). Our study population of 1047 diabetic patients was 51.7% male, had a mean age of 60.4 years, a mean duration of diabetes of 9.6 years, and a mean hemoglobin A1c of 8.3%. During the study period, 77.5% of patients received a screening eye examination with examination by an ophthalmologist, an optometrist, or review of a retinal photograph. Of those with a visual acuity assessment (n = 687, 65.6% of 1047), 1.5% had visual acuity of 20/200 or worse (legally blind) in the better eye, while 8.2% had this level of visual acuity in the worse eye. Of eyes with new onset clinically significant macular edema and visual acuity < 20/40, 40% had documentation of focal laser performed within 1 month of diagnosis. Of eyes with vitreous hemorrhage and visual acuity < 20/40, 50% had documentation of vitrectomy. Among eyes that had vitrectomy, over 80% had this procedure within 1 year of diagnosis of vitreous hemorrhage. The current report is the largest study of diabetic retinopathy outcomes among patients enrolled in a prepaid health plan. Further research is necessary to investigate the impact of managed care on health outcomes.
Ang, Marcus; Soh, Yuqiang; Htoon, Hla Myint; Mehta, Jodhbir S; Tan, Donald
2016-08-01
To compare 5-year graft survival after Descemet stripping automated endothelial keratoplasty (DSAEK) and penetrating keratoplasty (PK) in Asian eyes. Prospective, nested, cohort study. Consecutive patients who underwent DSAEK (423 eyes) or PK (405 eyes) for Fuchs' endothelial dystrophy (FED) or bullous keratopathy (BK). Clinical data and donor and recipient characteristics were recorded from our prospective cohort from the Singapore Corneal Transplant Registry. All surgeries were performed by the corneal surgeons at our center, which included cases performed or partially performed by corneal fellows in training under direct supervision. Five-year cumulative graft survival. Overall mean age was 67.8±9.8 years, and 50.1% of patients were men. There were no significant differences in age (P = 0.261) or gender (P = 0.78) between PK and DSAEK groups in our predominantly Chinese (76.6%) Asian cohort, with more BK compared with FED (68.1% vs. 31.9%; P < 0.001). Overall 5-year graft survival was superior for DSAEK compared with PK (79.4% vs. 66.5%; P < 0.001, log-rank test). Median 5-year percent endothelial cell density loss was significantly greater in PK compared with DSAEK (60.9% vs. 48.7%; P = 0.007). Cox regression analysis revealed that BK was a significant factor associated with graft failure (hazard ratio [HR], 3.30; 95% confidence interval [CI], 2.05-5.33; P < 0.001), and PK was more likely to fail compared with endothelial keratoplasty (HR, 1.61; 95% CI, 1.08-2.41; P = 0.02) adjusting for confounders such as recipient age, gender, and donor factors. Five-year cumulative incidence of complications such as graft rejection (P < 0.001), epitheliopathy (P < 0.001), suture-related corneal infections (P < 0.001), and wound dehiscence (P = 0.002) were greater in the PK group compared with the DSAEK group. In Asian eyes from the same study cohort with standardized surgical and postoperative regimes, 5-year graft survival was superior for DSAEK compared with PK in eyes with FED and BK. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Bertsch-Gout, Marcel; Loeb, Richard; Finch, Ashley K; Javed, Adil; Bernard, Jacqueline
2018-01-15
There is a need for biomarkers that can classify optic neuritis (ON) attacks as belonging to either neuromyelitis optica spectrum disorder with optic neuritis (NMOSD-ON) or relapsing remitting multiple sclerosis with optic neuritis (MS-ON). This study uses spectral domain optical coherence tomography (SD-OCT) data to perform a preliminary contrast between NMOSD-ON and MS-ON by analyzing peripapillary retinal nerve fiber layer and intra-macular layer patterns of injury. In this cross-sectional study, we used SD-OCT to obtain peripapillary retinal nerve fiber layer and intra-macular layer data for 26 NMOSD-ON, 25 MS-ON, and 26 healthy control (HC) age-matched eyes. Additionally, sub-comparisons compared 11 NMOSD-ON eyes that were seronegative for IgG antibodies against aquaporin 4 (NMOSD-ON (-)) and 16 NMOSD-ON eyes that were seropositive (NMOSD-ON (+)) to age-matched MS-ON eyes. Layer thicknesses were assessed using an automated algorithm and were then statistically compared using generalized estimating equations to account for inter-eye correlations. Selective thinning was found in the pRNFL, mRNFL, and GCL in NMOSD-ON compared to MS-ON. Thinning in the pRNFL nasal sector was found to persist in both NMOSD-ON (-) (P=0.017) and NMOSD-ON (+) (P=0.021) compared to MS-ON. Thinning in the mRNFL temporal sector was found to persist in NMOSD-ON (+) compared to MS-ON. Diffuse thinning was found in the pRNFL, mRNFL, GCL and IPL in NMOSD-ON compared to HC, and while diffuse thinning was also found in the GCL and IPL in MS-ON compared to HC, selective thinning was found in the pRNFL and mRNFL. The nasal region of the pRNFL may be capable of distinguishing between NMOSD-ON and MS-ON regardless of antibody status. Additionally, NMOSD-ON may cause more profound nasal axonal and inferior arcuate neuronal degeneration compared to MS-ON. Copyright © 2017 Elsevier B.V. All rights reserved.
Reivitis, Alex; Karimi, Kian; Griffiths, Chester; Banayan, Ashley
2018-04-16
Topical treatments containing tripeptide and hexapeptide (TriHex technology) have been proven to contribute to youthful skin by clearing the extracellular matrix and stimulating collagen and elastin production. Evaluate the efficacy of a novel eye treatment containing TriHex peptides and other synergistic ingredients for the daily treatment of fine lines/crow's feet around the eyes, under eye hollowing, under eye bags, and dark circles. In this study, 10 subjects (9 female and 1 male) aged 30-60 of Fitzpatrick skin type I, II, or III were selected to use an eye treatment containing TriHex peptides and active botanicals (Alastin Restorative Eye Treatment with TriHex Technology™, ALASTIN Skincare, Inc., Carlsbad, CA) twice daily for 12 weeks. Subjects were photographed and evaluated at baseline, week 4, week 8, and week 12 by a board-certified facial plastic surgeon. Using an adjusted Griffiths scale (0 = none, best possible condition and 9 = severe, worst possible condition), subjects were evaluated on severity of fine lines/crow's feet, under eye hollowing, under eye bags, and dark circles at each visit. Subjects completed a "Subject Questionnaire" at week 4, week 8, and week 12 pertaining to the subject's observations and perceived improvement of these measures. Based on the investigator's assessments, overall improvement in periocular skin was noted for all 10 subjects. Over the course of 12 weeks, raw scores significantly decreased indicating reduction of lines/crow's feet (41% improvement), under eye hollowing (29% improvement), under eye bags (48% improvement), and dark circles (39% improvement). Based on the "Subject Questionnaire," all subjects noted overall improvement of the appearance of skin around the eyes. Based on the findings of this study, this eye treatment containing TriHex peptides and active botanicals is an effective stand-alone treatment for the rejuvenation of periocular skin. When used twice daily, this product can reduce the appearance of lines/crow's feet, under eye hollowing, under eye bags, and dark circles. © 2018 Wiley Periodicals, Inc.
Biometric study of eyelid shape and dimensions of different races with references to beauty.
Rhee, Seung Chul; Woo, Kyoung-Sik; Kwon, Bongsik
2012-10-01
There are few studies that evaluate the differences in the perception of beauty and attractiveness of different races or ethnicities. The purpose of this study was to determine whether there are any actual differences in the configuration of beautiful eyes among different races. Using seven composite faces of different races or ethnicities, photogrammetric measurements were performed to determine the relative differences in the average and attractive configuration of the eyes. Fourteen distance measurements and five angular measurements were performed for analyzing the morphological differences in the configuration of attractive and average faces. The results of our study found that attractive Korean faces have relatively wide-set eyes and that the medial and lateral eye fissure height is greater than that in average Korean faces. Attractive Korean faces have larger but not ptotic eyes than those in average Korean faces and they have a narrow double fold line; however, attractive Asian faces have a slightly higher double fold line. Attractive Korean or Asian faces do not have an epicanthus and there is a lot of exposure of white in the medial and lateral area of the eyes. Attractive Caucasian and African faces have an acute or keen shape to the eyes like the jaguar's eye. Attractive Asian faces have a less steep slant of the palpebral fissure compared to that of the average Asian face, but attractive Caucasian and African faces have a steeper palpebral slant than that of average Caucasian and African faces. Attractive Caucasian and African faces have a relatively narrower palpebral fissure height and width than average Caucasian and African faces. Regardless of race, attractive faces have wide-set eyes and a lower brow position than average faces. "Beautiful eyes" can be defined as youthful, brilliant, vivid, and attractive. We found that there are some common and some different characteristics in the configuration of beautiful eyes according to racial background. This journal requires that authors assign a level of evidence to each article.
Jiang, Xiaodan; Lv, Huibin; Qiu, Weiqiang; Liu, Ziyuan; Li, Xuemin; Wang, Wei
2015-01-01
Dry eye is a chronic inflammatory ocular surface disease with high prevalence. The current therapies for dry eye remain to be unspecific and notcomprehensive. This study aims to explore safety and efficacy of a novel treatment - subconjunctival injection of bevacizumab - in dry eye patients. Sixty-four eyes of 32 dry eye patients received subconjunctival injection of 100 μL 25 mg/mL bevacizumab. Dry eye symptoms, signs (corrected visual acuity, intraocular pressure, conjunctival vascularity, corneal staining, tear break-up time, Marx line score, and blood pressure), and conjunctival impression cytology were evaluated 3 days before and 1 week, 1 month, and 3 months after injection. Significant improvements were observed in dry eye symptoms, tear break-up time, and conjunctival vascularization area at all the visits after injection compared to the baseline (P<0.05). The density of the goblet cell increased significantly at 1 month and 3 months after injection (P<0.05). There was no visual and systemic threat observed in any patient. Subconjunctival injection of 100 μL 25 mg/mL bevacizumab is a safe and efficient treatment for ocular surface inflammation of dry eye disease.
Design of liposomal colloidal systems for ocular delivery of ciprofloxacin
Taha, Ehab I.; El-Anazi, Magda H.; El-Bagory, Ibrahim M.; Bayomi, Mohsen A.
2013-01-01
Ophthalmic drug bioavailability is limited due to protective mechanisms of the eye which require the design of a system to enhance ocular delivery. In this study several liposomal formulations containing ciprofloxacin (CPX) have been formulated using reverse phase evaporation technique with final dispersion of pH 7.4. Different types of phospholipids including Phosphatidylcholine, Dipalmitoylphosphatidylcholine and Dimyristoyl-sn-glycero-3-phosphocholine were utilized. The effect of formulation factors such as type of phospholipid, cholesterol content, incorporation of positively charging inducing agents and ultrasonication on the properties of the liposomal vesicles was studied. Bioavailability of selected liposomal formulations in rabbit eye aqueous humor has been investigated and compared with that of commercially available CPX eye drops (Ciprocin®). Pharmacokinetic parameters including Cmax, Tmax, elimination rate constant, t1/2, MRT and AUC0–∞, were determined. The investigated formulations showed more than three folds of improvement in CPX ocular bioavailability compared with the commercial product. PMID:25061409
Creation and use of a survey instrument for comparing mobile computing devices.
Macri, Jennifer M; Lee, Paul P; Silvey, Garry M; Lobach, David F
2005-01-01
Both personal digital assistants (PDAs) and tablet computers have emerged to facilitate data collection at the point of care. However, little research has been reported comparing these mobile computing devices in specific care settings. In this study we present an approach for comparing functionally identical applications on a Palm operating system-based PDA and a Windows-based tablet computer for point-of-care documentation of clinical observations by eye care professionals when caring for patients with diabetes. Eye-care professionals compared the devices through focus group sessions and through validated usability surveys. This poster describes the development and use of the survey instrument used for comparing mobile computing devices.
Ho, Kam Chun; Jalbert, Isabelle; Watt, Kathleen; Golebiowski, Blanka
2017-07-01
To examine the relationship between dry eye symptoms and adiposity in a population study. A prospective cross-sectional single-visit preliminary study was designed to sample ocular symptoms and indices of adiposity in the general adult population. Patients recruited from the UNSW optometry clinic, the university campus and surrounding community, and overseas were invited to complete a survey composed of the short form Dry Eye Questionnaire (SFDEQ) (Dry Eye Questionnaire-5 or Contact Lens Dry Eye Questionnaire-8) and the Ocular Comfort Index (OCI) via hardcopy or online. Participants self-measured their weight, height, waist circumference (WC), and body fat % (optional). Associations between measures of adiposity (Body mass index [BMI], WC, and body fat %) and ocular symptoms scores (SFDEQ and OCI) were determined using Spearman correlation coefficients. Group differences were compared using independent t test. Three hundred and five participants including 52 contact lens wearers completed the study and 78 of them measured body fat %. There was a moderate correlation between body fat % and dry eye symptoms (SFDEQ r=0.34, P=0.003; OCI r=0.32, P=0.004). The interaction between body fat % and gender, wear of contact lenses, and older age were shown to be significant predictors of less ocular comfort in multivariate analysis (F(3,74)=12.13, P<0.001). An association between adiposity measured by body fat % and symptoms of dry eye was demonstrated in the general adult population. Confirmation of these findings in a large study is required.
Domienik, J; Farah, J; Struelens, L
2016-12-01
The first validation results of the two approaches developed in the ELDO project for retrospective assessment of eye lens doses for interventional cardiologists (ICs) are presented in this paper. The first approach (a) is based on both the readings from the routine whole body dosimeter worn above the lead apron and procedure-dependent conversion coefficients, while the second approach (b) is based on detailed information related to the occupational exposure history of the ICs declared in a questionnaire and eye lens dose records obtained from the relevant literature. The latter approach makes use of various published eye lens doses per procedure as well as the appropriate correction factors which account for the use of radiation protective tools designed to protect the eye lens. To validate both methodologies, comprehensive measurements were performed in several Polish clinics among recruited physicians. Two dosimeters measuring whole body and eye lens doses were worn by every physician for at least two months. The estimated cumulative eye lens doses, calculated from both approaches, were then compared against the measured eye lens dose value for every physician separately. Both approaches results in comparable estimates of eye lens doses and tend to overestimate rather than underestimate the eye lens doses. The measured and estimated doses do not differ, on average, by a factor higher than 2.0 in 85% and 62% of the cases used to validate approach (a) and (b), respectively. In specific cases, however, the estimated doses differ from the measured ones by as much as a factor of 2.7 and 5.1 for method (a) and (b), respectively. As such, the two approaches can be considered accurate when retrospectively estimating the eye lens doses for ICs and will be of great benefit for ongoing epidemiological studies.
Arikan, Gul; Osman Saatci, Ali; Hakan Oner, Ferit
2011-01-01
AIM To evaluate prospectively immediate intraocular pressure (IOP) changes after the intravitreal injection of ranibizumab, 2 and 4mg triamcinolone acetonide. METHODS Patients who underwent intravitreal injection of 0.1mL (4mg) triamcinolone acetonide (TA, Group T4), 0.05mL (2mg) TA (Group T2) and 0.05mL (0.5mg) ranibizumab (Group R) comprised the study population. Overall, 229 eyes of 205 patients were injected. Fifty-four eyes (23.6%) were in Group T4, 69 eyes (30.1%) in Group T2 and 106 eyes (46.3%) in Group R. If IOP was less than 26mmHg immediately after the injection no further measurement was performed. If IOP was ≥26mmHg, IOP was remeasured till the reading was below 26mmHg at 5, 15 and 30 minutes. RESULTS Immediately after the injection, the IOP of 28 eyes (51.9%) in Group T4, 22 eyes (31.9%) in Group T2 and 51 eyes (48.1%) in Group R were over 25mmHg. At 30 minutes, IOP of one eye (1.9%) in group T4, two eyes (2.9%) in group T2 and two eyes (1.9 %) in Group R were over 25mmHg. Immediate post-injection IOP was significantly higher in Group T4 and Group R when compared to Group T2 (P<0.001 and P<0.001, respectively). IOP was significantly higher in eyes without vitreous reflux when compared to those with vitreous reflux in all groups (P<0.001). CONCLUSION IOP may remarkably increase immediately after the intravitreal injection of 2 or 4mg triamcinolone acetonide, and 0.5mg ranibizumab. Absence of vitreous reflux is the most important predicting factor for immediate IOP rise after the injection. PMID:22553690
Effect of Oral Lactoferrin on Cataract Surgery Induced Dry Eye: A Randomised Controlled Trial.
Devendra, Jaya; Singh, Sneha
2015-10-01
Cataract surgery is one of the most frequently performed intra-ocular surgeries, of these manual Small Incision Cataract Surgery (SICS) is a time tested technique of cataract removal. Any corneal incisional surgery, including cataract surgery, can induce dry eye postoperatively. Various factors have been implicated, of which oneis the inflammation induced by the surgery. Lactoferrin, a glycoprotein present in tears is said to have anti-inflammatory effects, and promotes cell growth. It has been used orally in patients of immune mediated dry eye to alleviate symptoms. This study was aimed to evaluate the dry eyes induced by manual Small Incision Cataract Surgery, and the effect if any, of oral lactoferrin on the dry eyes. A single centre, prospective randomised controlled trial with a concurrent parallel design. The study was carried out on patients presenting in the OPD of Rohilkhand Medical College hospital for cataract surgery. Sixty four patients of cataract surgery were included in the study. Patients with pre-existing dry eyes, ocular disease or systemic disease predisposing to dry eyes were excluded from the study. The selected patients were assigned into two groups by simple randomisation-Control Group A-32 patients that did not receive oral lactoferrin postoperatively. Group B-32 patients that received oral lactoferrin 350 gm postoperatively from day 1 after SICS. All patients were operated for cataract and their pre and postoperative (on days 7, 14, 30 and 60) dry eye status was assessed using the mean tear film break-up time (tBUT) and Schirmer test 1 (ST 1) as the evaluating parameters. Subjective evaluation of dry eye was done using Ocular Surface Disease Index (OSDI) scoring. Data was analysed for 58 patients, as 6 did not complete the follow up. Unpaired t-test was used to calculate the p-values. There was a statistically significant difference between the tBUT values of the Control and Lactoferrin group from day 14 onwards. The tBUT of control group on day 60 was 7.86 (±0.86) seconds as compared to 13.9(± 0.99) seconds in the lactoferrin group. The Schirmer test 1 values also showed a statistically significant difference between the two groups- 15.86 (± 5.83) seconds in the control group versus 30.9 (±1.66) in the lactoferrin group on day 60. OSDI score showed 42.8% patients complaining of at least mild dry eye symptoms in the control group, as compared to 26.6% patients in the lactoferrin group on day 60. Small Incision Cataract Surgery induces dry eye postoperatively. Oral lactoferrin given postoperatively improves tear film status and dry eye after cataract surgery.
Frames of reference for gaze saccades evoked during stimulation of lateral intraparietal cortex.
Constantin, A G; Wang, H; Martinez-Trujillo, J C; Crawford, J D
2007-08-01
Previous studies suggest that stimulation of lateral intraparietal cortex (LIP) evokes saccadic eye movements toward eye- or head-fixed goals, whereas most single-unit studies suggest that LIP uses an eye-fixed frame with eye-position modulations. The goal of our study was to determine the reference frame for gaze shifts evoked during LIP stimulation in head-unrestrained monkeys. Two macaques (M1 and M2) were implanted with recording chambers over the right intraparietal sulcus and with search coils for recording three-dimensional eye and head movements. The LIP region was microstimulated using pulse trains of 300 Hz, 100-150 microA, and 200 ms. Eighty-five putative LIP sites in M1 and 194 putative sites in M2 were used in our quantitative analysis throughout this study. Average amplitude of the stimulation-evoked gaze shifts was 8.67 degrees for M1 and 7.97 degrees for M2 with very small head movements. When these gaze-shift trajectories were rotated into three coordinate frames (eye, head, and body), gaze endpoint distribution for all sites was most convergent to a common point when plotted in eye coordinates. Across all sites, the eye-centered model provided a significantly better fit compared with the head, body, or fixed-vector models (where the latter model signifies no modulation of the gaze trajectory as a function of initial gaze position). Moreover, the probability of evoking a gaze shift from any one particular position was modulated by the current gaze direction (independent of saccade direction). These results provide causal evidence that the motor commands from LIP encode gaze command in eye-fixed coordinates but are also subtly modulated by initial gaze position.
Della Mea, Giovanni; Bacchetti, Sonia; Zeppieri, Marco; Brusini, Paolo; Cutuli, Daniela; Gigli, Gian Luigi
2007-01-01
To evaluate the ability of GDx with variable corneal compensator (VCC) compared to visual-evoked potentials (VEPs) and standard automated perimetry (SAP) in the detection of early optic nerve damage in patients with multiple sclerosis (MS). 46 eyes of 23 MS patients were included. Ten of them had a history of acute retrobulbar optic neuritis. A control group of 20 normal subjects was also included. All subjects underwent a complete ophthalmological examination and testing with SAP, GDx VCC and VEPs. 19 eyes (41.3%) were abnormal with GDx VCC compared to 38 eyes (82.6%) with SAP and 31 (64.4%) with VEPs. In the optic neuritis group, 9 eyes (69.2%) had optic nerve pallor; SAP was abnormal in 8 of these eyes (61.5%) while VEPs and GDx VCC were abnormal in 6 eyes (46.1%). 2/20 eyes (10.0%) in the control group gave a false-positive abnormal result with SAP. GDx VCC and VEP were normal for all the eyes in the control group. GDx VCC is less able to detect early defects in MS patients compared to the currently used standard techniques of SAP and VEPs. Copyright (c) 2007 S. Karger AG, Basel.
Cat-scratch disease: ocular manifestations and treatment outcome.
Habot-Wilner, Zohar; Trivizki, Omer; Goldstein, Michaella; Kesler, Anat; Shulman, Shiri; Horowitz, Josepha; Amer, Radgonde; David, Ran; Ben-Arie-Weintrob, Yael; Bakshi, Erez; Almog, Yehoshua; Sartani, Gil; Vishnevskia-Dai, Vicktoria; Kramer, Michal; Bar, Asaf; Kehat, Rinat; Ephros, Moshe; Giladi, Michael
2018-03-05
To characterize cat-scratch disease (CSD) ocular manifestations and visual outcome and evaluate the effect of systemic antibiotics and corticosteroids on final visual acuity (VA). Multicentre retrospective cohort study. Medical records of 86 patients with ocular disease (107 eyes) of 3222 patients identified in a national CSD surveillance study were reviewed. Mean age was 35.1 ± 14.2 years. Median follow-up was 20 weeks (range 1-806 weeks). Of 94/107 (88%) eyes with swollen disc, 60 (64%) had neuroretinitis at presentation, 14 (15%) developed neuroretinitis during follow-up, and 20 (21%) were diagnosed with inflammatory disc oedema. Optic nerve head lesion, uveitis, optic neuropathy and retinal vessel occlusion were found in 43 (40%), 38 (36%), 34 (33%) and 8 (7%) eyes, respectively. Good VA (better than 20/40), moderate vision loss (20/40-20/200) and severe vision loss (worse than 20/200) were found in 26/79 (33%), 35/79 (44%) and 18/79 (23%) eyes at baseline and in 63/79 (80%), 11/79 (14%) and 5/79 (6%) eyes at final follow-up, respectively (p < 0.001). Significant VA improvement (defined as improvement of ≥3 Snellen lines at final follow-up compared to baseline) occurred in 12/24 (50%) eyes treated with antibiotics compared with 14/16 (88%) eyes treated with antibiotics and corticosteroids (p = 0.02). Multivariate logistic regression was suggestive of the same association (odds ratio 7.0; 95% CI 1.3-37.7; p = 0.024). Optic nerve head lesion is a common and unique manifestation of ocular CSD. Most patients improved and had final good VA. Combined antibiotics and corticosteroid treatment was associated with a better visual outcome. © 2018 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Zheng, Gaoxing; Qi, Xiaoying; Li, Yuzhu; Zhang, Wei; Yu, Yuguo
2018-01-01
The choice of different reference electrodes plays an important role in deciphering the functional meaning of electroencephalography (EEG) signals. In recent years, the infinity zero reference using the reference electrode standard technique (REST) has been increasingly applied, while the average reference (AR) was generally advocated as the best available reference option in previous classical EEG studies. Here, we designed EEG experiments and performed a direct comparison between the influences of REST and AR on EEG-revealed brain activity features for three typical brain behavior states (eyes-closed, eyes-open and music-listening). The analysis results revealed the following observations: (1) there is no significant difference in the alpha-wave-blocking effect during the eyes-open state compared with the eyes-closed state for both REST and AR references; (2) there was clear frontal EEG asymmetry during the resting state, and the degree of lateralization under REST was higher than that under AR; (3) the global brain functional connectivity density (FCD) and local FCD have higher values for REST than for AR under different behavior states; and (4) the value of the small-world network characteristic in the eyes-closed state is significantly (in full, alpha, beta and gamma frequency bands) higher than that in the eyes-open state, and the small-world effect under the REST reference is higher than that under AR. In addition, the music-listening state has a higher small-world network effect than the eyes-closed state. The above results suggest that typical EEG features might be more clearly presented by applying the REST reference than by applying AR when using a 64-channel recording. PMID:29593490
Serna-Ojeda, Juan Carlos; Nava-Castaneda, Angel
2017-03-01
To evaluate the efficacy of botulinum toxin type A injection to cause orbicularis eyelid muscle paralysis to improve dry eye signs and symptoms. A prospective, randomized, comparative eye-to-eye and interventional study was performed. Patients with dry eye symptoms and positive fluorescein corneal staining were included. Randomly one eyelid received a subcutaneous injection of botulinum toxin in the medial orbicularis muscle portion of the lower eyelid, and the other eye received placebo. The subjective evaluation was achieved with a questionnaire assessing symptoms, quality of vision and ocular comfort level. The objective evaluation included the measurement of the tear film break-up time (TBUT), Schirmer's test and corneal and conjunctival staining. Twenty patients were included with a mean age of 59.5 years. Two weeks after the botulinum toxin injection, all patients showed a decrease in the horizontal movement of the lower eyelid when blinking. The eyes in the active treatment group showed better scores compared with the sham group in four symptoms 4 weeks after the treatment. The TBUT was higher at 1 and 3 months in the active treatment group. The corneal and conjunctival staining were significantly lower in the active treatment group at 1 and 3 months, and the Schirmer's test showed better measurements in the same group at 2 weeks, 1 month and 3 months. There were no adverse events reported. The injection of botulinum toxin A in the medial part of the lower eyelid is an effective and safe procedure that temporally improves some of the signs and symptoms of patients with dry eye. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Myopic refractive shift represents dense nuclear sclerosis and thin lens in lenticular myopia.
Cho, Yang Kyung; Huang, Wei; Nishimura, Eiichi
2013-09-01
It is not rare to meet unilateral nuclear sclerotic cataracts with myopic refractive changes (lenticular myopia) compared with the fellow eye in the ophthalmic examination of patients with decreased visual acuity. To determine the relationship between the myopic refractive changes and interocular differences of parameters, we investigated the interocular differences of ocular parameters between a lenticular myopic eye and the fellow eye. This retrospective study included 68 eyes of 34 patients, who showed unilateral lenticular myopia. We compared the dimensions of ocular component, such as anterior chamber depth, anterior chamber volume, lens thickness, vitreous chamber depth, lens position, lens density of nuclear sclerosis, anterior lens curvature and myopic refractive changes (spherical equivalent refraction) between the lenticular myopic eye and the myopic refractive change were examined. Statistically significant differences were found between the lenticular myopic eye and the fellow eye for anterior chamber depth (p = 0.015) anterior chamber volume (p = 0.031), lens thickness (p < 0.001), lens density of the nuclear sclerosis (p < 0.001) and the spherical equivalent myopic refractive changes (p < 0.001). Based on univariate analysis, the interocular difference in spherical equivalent refraction was significantly correlated with interocular differences of the density of the nuclear sclerosis (r = 0.79, p < 0.001), lens thickness (r = -0.70, p < 0.001) and vitreous chamber depth (r = 0.43, p = 0.012). Based on multiple regression analysis, the interocular difference in spherical equivalent refraction was significantly correlated with interocular differences of density of nuclear sclerosis (p < 0.001) and lens thickness (p = 0.007). The difference in myopic spherical change reflects the differences in the severity of nuclear sclerosis and lens thickness between the lenticular myopic eye and the fellow eye. © 2013 The Authors. Clinical and Experimental Optometry © 2013 Optometrists Association Australia.
Kaido, Minako; Ishida, Reiko; Dogru, Murat; Tsubota, Kazuo
2011-09-01
To investigate the relation of functional visual acuity (FVA) measurements with dry eye test parameters and to compare the testing methods with and without blink suppression and anesthetic instillation. A prospective comparative case series. Thirty right eyes of 30 dry eye patients and 25 right eyes of 25 normal subjects seen at Keio University School of Medicine, Department of Ophthalmology were studied. FVA testing was performed using a FVA measurement system with two different approaches, one in which measurements were made under natural blinking conditions without topical anesthesia (FVA-N) and the other in which the measurements were made under the blink suppression condition with topical anesthetic eye drops (FVA-BS). Tear function examinations, such as the Schirmer test, tear film break-up time, and fluorescein and Rose Bengal vital staining as ocular surface evaluation, were performed. The mean logMAR FVA-N scores and logMAR Landolt visual acuity scores were significantly lower in the dry eye subjects than in the healthy controls (p < 0.05), while there were no statistical differences between the logMAR FVA-BS scores of the dry eye subjects and those of the healthy controls. There was a significant correlation between the logMAR Landolt visual acuities and the logMAR FVA-N and logMAR FVA-BS scores. The FVA-N scores correlated significantly with tear quantities, tear stability and, especially, the ocular surface vital staining scores. FVA measurements performed under natural blinking significantly reflected the tear functions and ocular surface status of the eye and would appear to be a reliable method of FVA testing. FVA measurement is also an accurate predictor of dry eye status.
Ozge, Gokhan; Koylu, Mehmet Talay; Mumcuoglu, Tarkan; Gundogan, Fatih Cakir; Ozgonul, Cem; Ayyildiz, Onder; Kucukevcilioglu, Murat
2016-05-01
To compare retinal nerve fiber layer thickness (RNFLT) and choroidal thickness (ChT) measurements in eyes with pseudoexfoliative (PEX) glaucoma, PEX syndrome and healthy control eyes. Eighteen patients with PEX glaucoma in one eye and PEX syndrome in the fellow eye were included. The right eyes of thirty-nine age- and sex-matched healthy subjects were included as control group. All participants underwent a detailed biomicroscopic and funduscopic examination. RNFLT and ChT measurements were performed with a commercially available spectral-domain optical coherence tomography (SD-OCT). ChT measurements were performed by using enhanced depth imaging (EDI) mode. Patients with PEX underwent diurnal IOP measurements with 4-hour intervals before inclusion in the study. RNFLT results included the average measurement and 6 quadrants (temporal, inferotemporal, inferonasal, nasal, superonasal and supero-temporal). ChT measurements were performed in the subfoveal region and around the fovea (500µm and 1500 µm nasal and temporal to the fovea), as well as around the optic disc (average peripapillary and eight quadrants in the peripapillary region (temporal, inferotemporal, inferior, inferonasal, nasal, superonasal, superior, supero-temporal)). RNFLT in all quadrants and average thickness were significantly lower in PEX glaucoma eyes compared to PEX syndrome eyes and healthy control eyes (p<0.001 for both). RNFLT comparisons between PEX syndrome and healthy control eyes did not show a significant difference (p>0.05) except the inferotemporal quadrant. ChT measurements were similar between groups (p>0.05). Thinning of the RNFL in association with unchanged ChT may mean that the presence of PEX material is a much more significant risk factor than choroidal changes in the progression of PEX syndrome to PEX glaucoma.
Exploring the Lack of a Disfluency Effect: Evidence from Eye Movements
ERIC Educational Resources Information Center
Strukelj, Alexander; Scheiter, Katharina; Nyström, Marcus; Holmqvist, Kenneth
2016-01-01
An eye-tracking study with 60 native Swedish speakers (18-30 years) was conducted to investigate the positive effects on learning outcomes predicted by the disfluency effect. Subtle low-pass filtering was used as a disfluency manipulation and compared with a control condition using regular text. The text was presented on four separate text…
ERIC Educational Resources Information Center
Yeari, Menahem; Oudega, Marja; van den Broek, Paul
2017-01-01
The present study investigated the effect of text highlighting on online processing and memory of central and peripheral information. We compared processing time (using eye-tracking methodology) and recall of central and peripheral information for three types of highlighting: (a) highlighting of central information, (b) highlighting of peripheral…
Same Same, but Different: Word and Sentence Reading in German and English
ERIC Educational Resources Information Center
Rau, Anne K.; Moll, Kristina; Moeller, Korbinian; Huber, Stefan; Snowling, Margaret J.; Landerl, Karin
2016-01-01
The current study compared eye fixation patterns during word and sentence processing in a consistent and an inconsistent alphabetic orthography. German and English children as well as adults matched on word reading ability read matched sentences while their eye fixation behavior was recorded. Results indicated that German children read in a more…
ERIC Educational Resources Information Center
Calkins, Monica E.; Iacono, William G.; Ones, Deniz S.
2008-01-01
Several forms of eye movement dysfunction (EMD) are regarded as promising candidate endophenotypes of schizophrenia. Discrepancies in individual study results have led to inconsistent conclusions regarding particular aspects of EMD in relatives of schizophrenia patients. To quantitatively evaluate and compare the candidacy of smooth pursuit,…
Von Zup, M; Lassaline, M; Kass, P H; Miller, P E; Thomasy, S M
2017-11-01
Brimonidine is an α 2 -adrenergic agonist that decreases aqueous humour production and may increase uveoscleral outflow. It has not been evaluated in normal or glaucomatous equine eyes. To evaluate the efficacy and safety of brimonidine in lowering intraocular pressure (IOP), alone and in conjunction with timolol, as a treatment for equine glaucoma by comparing IOP in normal equine eyes treated with brimonidine and brimonidine-timolol, respectively, with IOP in control eyes. A balanced crossover design with 16 horses receiving one of two treatments, brimonidine and brimonidine-timolol, during each of two 10-day study phases, was used. Four horses were randomly assigned to each of four combinations of treated eye (right or left) and drug order within the two 10-day study phases (brimonidine first or brimonidine-timolol first). Pupil size and conjunctival hyperaemia were assessed twice per day and IOP was measured three times per day using rebound tonometry in both eyes of 16 normal horses throughout two 10-day study periods (brimonidine and brimonidine-timolol) separated by an 18-day washout period. One eye of each horse was treated with brimonidine or brimonidine-timolol and the opposite eye was treated with balanced salt solution (BSS). There were no adverse effects and no significant changes in pupil size in normal equine eyes treated with brimonidine or brimonidine-timolol. Average IOP in normal equine eyes treated with brimonidine (25.6 mmHg) was statistically higher than in eyes treated with brimonidine-timolol (24.6 mmHg) or BSS (24.5 mmHg). However, IOP differences were of ≤1 mmHg and thus not clinically important. Horses with normal eyes may not be as sensitive to the IOP-lowering effects of treatment as horses with glaucoma. Brimonidine and brimonidine-timolol are well tolerated in normal horses but do not decrease IOP. © 2017 EVJ Ltd.
Zhang, Chen; Xi, Lei; Zhao, Shaozhen; Wei, Ruihua; Huang, Yue; Yang, Ruibo; Su, Long; Liu, Xun
2016-08-03
To compare expression of interleukin (IL)-1β and tumour necrosis factor (TNF)-α in the conjunctiva of diabetic and non-diabetic patients with symptomatic moderate dry eye. Nineteen diabetic patients with dry eye, 15 non-diabetic patients with dry eye and 14 diabetic patients without dry eye were recruited. The relative expression of IL-1β and TNF-α in conjunctival impression cytology (CIC) specimens was evaluated using immunofluorescent staining and in conjunctival biopsy specimens using immunohistochemical staining. The diabetic dry eye group showed significantly higher grades of metaplasia than the non-diabetic dry eye and diabetic without dry eye groups (both p<0.05). There was no significant difference in the concentration of IL-1β and TNF-α in CIC specimens between the three groups (p=0.504 and p=0.310, respectively). The mean levels of IL-1β and TNF-α in conjunctival biopsy specimens from the diabetic dry eye group was significantly increased compared with the non-diabetic dry eye and diabetic without dry eye groups (p=0.002, p<0.001; p=0.001, p<0.001, respectively). Interestingly, IL-1β- and TNF-α-positive cells were mainly located in the basal layer of the conjunctival epithelium, and rarely seen in the apical conjunctival epithelium in the three groups. The levels of both IL-1β and TNF-α did not correlate with conjunctival squamous metaplasia grades. Levels of IL-1β and TNF-α in conjunctival biopsy specimens were increased in diabetic patients with dry eye, while levels of IL-1β and TNF-α in apical conjunctival epithelium were similar in the CIC specimens. These findings suggest that the inflammatory response is not limited to the surface of conjunctival epithelial cells, and is more serious in the basal layer of the epithelium, which may play an important role in the pathogenesis of dry eye in diabetic patients. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Zhang, Chen; Xi, Lei; Zhao, Shaozhen; Wei, Ruihua; Huang, Yue; Yang, Ruibo; Su, Long; Liu, Xun
2016-01-01
Objectives To compare expression of interleukin (IL)-1β and tumour necrosis factor (TNF)-α in the conjunctiva of diabetic and non-diabetic patients with symptomatic moderate dry eye. Setting and participants Nineteen diabetic patients with dry eye, 15 non-diabetic patients with dry eye and 14 diabetic patients without dry eye were recruited. The relative expression of IL-1β and TNF-α in conjunctival impression cytology (CIC) specimens was evaluated using immunofluorescent staining and in conjunctival biopsy specimens using immunohistochemical staining. Results The diabetic dry eye group showed significantly higher grades of metaplasia than the non-diabetic dry eye and diabetic without dry eye groups (both p<0.05). There was no significant difference in the concentration of IL-1β and TNF-α in CIC specimens between the three groups (p=0.504 and p=0.310, respectively). The mean levels of IL-1β and TNF-α in conjunctival biopsy specimens from the diabetic dry eye group was significantly increased compared with the non-diabetic dry eye and diabetic without dry eye groups (p=0.002, p<0.001; p=0.001, p<0.001, respectively). Interestingly, IL-1β- and TNF-α-positive cells were mainly located in the basal layer of the conjunctival epithelium, and rarely seen in the apical conjunctival epithelium in the three groups. The levels of both IL-1β and TNF-α did not correlate with conjunctival squamous metaplasia grades. Conclusions Levels of IL-1β and TNF-α in conjunctival biopsy specimens were increased in diabetic patients with dry eye, while levels of IL-1β and TNF-α in apical conjunctival epithelium were similar in the CIC specimens. These findings suggest that the inflammatory response is not limited to the surface of conjunctival epithelial cells, and is more serious in the basal layer of the epithelium, which may play an important role in the pathogenesis of dry eye in diabetic patients. PMID:27489152
Lobo, Ann-Marie; Gao, Yan; Rusie, Laura; Houlberg, Magda; Mehta, Supriya D
2018-03-01
In 2015, the Centers for Disease Control and Prevention (CDC) and the American Academy of Ophthalmology (AAO) released clinical advisories on rising cases of ocular syphilis. We examined the association between eye disease and syphilis infection among primary care and sexually transmitted infection (STI) clinic patients attending an urban lesbian, gay, bisexual, transgender (LGBT) health center. We conducted a retrospective medical record review of all patients who underwent syphilis testing at Howard Brown Health between 1 January 2010 and 31 December 2015. Confirmed eye diagnosis was based on International Classification of Diseases, Ninth Revision (ICD-9) diagnosis codes for conjunctivitis, uveitis, keratitis, retinitis, and red eye. Demographic information, syphilis treatment, HIV status, and high-risk behaviors were abstracted. Syphilis diagnosis was defined by available laboratory data (enzyme immunoassay [EIA], rapid plasma reagin [RPR] titer, fluorescent treponemal antibody absorption [FTA-Abs], Treponema pallidum Ab). Multivariable logistic regression with robust variance was used to identify independent associations. During the study period, 71,299 syphilis tests were performed on 30,422 patients. There were 2288 (3.2%) positive syphilis tests. Seventy-seven patients had a confirmed eye diagnosis (0.25%). Patients with eye disease had higher probability of at least one positive syphilis test (33%) compared to those without eye disease (8%) ( p < 0.01). Of patients with eye disease, 77% were men who had sex with men (MSM) and 65% were HIV-positive. Patients with eye disease had 5.97 (95% CI: 3.70, 9.63) higher odds of having syphilis compared to patients without eye disease. When adjusted for age, race, gender/sexual orientation, insurance status, and HIV status, this association between positive syphilis test and eye disease decreased but was still significant (OR 2.00, 95% CI 1.17, 3.41). Patients who present with an eye diagnosis to STI/primary care clinic have a higher probability of positive syphilis tests even after adjusting for other risk factors for syphilis. High-risk patients with eye symptoms should have routine STI testing and in keeping with CDC and AAO recommendations, full ophthalmologic examination.
Drawing from Memory: Hand-Eye Coordination at Multiple Scales
Spivey, Michael J.
2013-01-01
Eyes move to gather visual information for the purpose of guiding behavior. This guidance takes the form of perceptual-motor interactions on short timescales for behaviors like locomotion and hand-eye coordination. More complex behaviors require perceptual-motor interactions on longer timescales mediated by memory, such as navigation, or designing and building artifacts. In the present study, the task of sketching images of natural scenes from memory was used to examine and compare perceptual-motor interactions on shorter and longer timescales. Eye and pen trajectories were found to be coordinated in time on shorter timescales during drawing, and also on longer timescales spanning study and drawing periods. The latter type of coordination was found by developing a purely spatial analysis that yielded measures of similarity between images, eye trajectories, and pen trajectories. These results challenge the notion that coordination only unfolds on short timescales. Rather, the task of drawing from memory evokes perceptual-motor encodings of visual images that preserve coarse-grained spatial information over relatively long timescales as well. PMID:23554894
Human Eye Phantom for Developing Computer and Robot-Assisted Epiretinal Membrane Peeling*
Gupta, Amrita; Gonenc, Berk; Balicki, Marcin; Olds, Kevin; Handa, James; Gehlbach, Peter; Taylor, Russell H.; Iordachita, Iulian
2014-01-01
A number of technologies are being developed to facilitate key intraoperative actions in vitreoretinal microsurgery. There is a need for cost-effective, reusable benchtop eye phantoms to enable frequent evaluation of these developments. In this study, we describe an artificial eye phantom for developing intraocular imaging and force-sensing tools. We test four candidate materials for simulating epiretinal membranes using a handheld tremor-canceling micromanipulator with force-sensing micro-forceps tip and demonstrate peeling forces comparable to those encountered in clinical practice. PMID:25571573
Patty, Lauren; Wu, Cathy; Torres, Mina; Azen, Stanley; Varma, Rohit
2012-09-01
To examine the validity of self-reported eye disease, including cataract, age-related macular degeneration (AMD), glaucoma, and diabetic retinopathy (DR), and self-reported surgical treatment for cataract and DR in the Los Angeles Latino Eye Study (LALES). Population-based, cross-sectional study. A total of 6357 Latinos aged 40+ years from the LALES. Participants underwent a detailed interview, including survey questions about ocular health, diagnoses, and timing of last eye examination, and a standardized clinical examination. Self-report was compared with examination to determine sensitivity and specificity by length of time since last eye examination. Stepwise logistic regression was used to determine factors associated with inaccurate self-report. Sensitivity and specificity were calculated for 4 self-reported eye diseases (cataract, AMD, glaucoma, and DR) and for surgical treatment of cataract and DR. Odds ratios (ORs) were determined for factors associated with inaccurate self-report underestimating eye disease and treatment. For each disease, sensitivity and specificity in those who reported their last eye examination as <1 year ago were 36.8% and 92.5% for cataract, 37.7% and 96.3% for glaucoma, 5.1% and 98.9% for AMD, and 25.7% and 94.2% for DR, respectively. Self-report was less accurate with increasing time since last eye examination. Inaccurate self-report was independently associated with better visual acuity (OR, 2.4), <2 comorbidities (OR, 1.7), last eye examination/visit 1 to 5 years ago and ≥ 5 years ago (OR, 2.3 and 4.9, respectively), and less education (OR, 1.3 for 7-12 years and 1.7 for <7 years). Of 88 participants surgically treated for cataract who reported an eye examination <1 year ago, sensitivity and specificity of self-reported surgical history were 90.9% and 99.9%, respectively. Of the 31 participants treated for DR (laser/surgery) and reporting an eye examination <1 year ago, sensitivity and specificity of self-reported surgical history were 19.4% and 99.6%, respectively. Among Latinos, self-reporting of eye disease and surgical history provides a significant underestimate of the disease burden. This may lead to significant misclassification in vision research if self-report alone is used to identify persons with eye disease. Copyright © 2012 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Patty, Lauren; Wu, Cathy; Torres, Mina; Azen, Stanley; Varma, Rohit
2012-01-01
Purpose To examine the validity of self-reported eye disease, including cataract, age-related macular degeneration (AMD), glaucoma, and diabetic retinopathy (DR), and self-reported surgical treatment for cataract and DR in the Los Angeles Latino Eye Study (LALES). Design Population-based cross-sectional study Participants 6357 Latinos age 40+ years from the LALES Methods Participants underwent a detailed interview, including survey questions about ocular health, diagnoses and timing of last eye examination, and a standardized clinical examination. Self report was compared to examination to determine sensitivity and specificity by length of time since last eye examination. Stepwise logistic regression was used to determine factors associated with inaccurate self report. Main Outcome Measures Sensitivity and specificity were calculated for four self reported eye diseases (cataract, AMD, glaucoma, DR) and for surgical treatment of cataract and DR. Odds ratios (OR) were determined for factors associated with inaccurate self report underestimating eye disease and treatment. Results For each disease, sensitivity and specificity in those who reported their last eye examination as <1 year ago were: 36.8%, 92.5% for cataract; 37.7%, 96.3% for glaucoma; 5.1%, 98.9% for AMD; and 25.7%, 94.2% for DR. Self report was less accurate with increasing time since last eye examination. Inaccurate self report was independently associated with better visual acuity (OR=2.4), <2 comorbidities (OR=1.7), last eye exam/visit 1–5 years ago and ≥5 years ago (OR=2.3 and 4.9, respectively), and less education (OR=1.3 for 7–12 years and 1.7 for <7 years). Of 88 participants surgically treated for cataract who reported an eye examination <1 year ago, sensitivity and specificity of self-reported surgical history were 90.9% and 99.9%. Of the 31 participants treated for DR (laser/surgery) and reporting an eye examination <1 year ago, sensitivity and specificity of self-reported surgical history were 19.4% and 99.6%. Conclusions Among Latinos, self reporting of eye disease and surgical history provides a significant underestimate of the disease burden. This may lead to significant misclassification in vision research if self report alone is used to identify persons with eye disease. PMID:22537615
Angle assessment by EyeCam, goniophotography, and gonioscopy.
Baskaran, Mani; Perera, Shamira A; Nongpiur, Monisha E; Tun, Tin A; Park, Judy; Kumar, Rajesh S; Friedman, David S; Aung, Tin
2012-09-01
To compare EyeCam (Clarity Medical Systems, Pleasanton, CA) and goniophotography in detecting angle closure, using gonioscopy as the reference standard. In this hospital-based, prospective, cross-sectional study, participants underwent gonioscopy by a single observer, and EyeCam imaging and goniophotography by different operators. The anterior chamber angle in a quadrant was classified as closed if the posterior trabecular meshwork could not be seen. A masked observer categorized the eyes as per the number of closed quadrants, and an eye was classified as having angle closure if there were 2 or more quadrants of closure. Agreement between the methods was analyzed by κ statistic and comparison of area under receiver operating characteristic curves (AUC). Eighty-five participants (85 eyes) were included, the majority of whom were Chinese. Angle closure was detected in 38 eyes (45%) with gonioscopy, 40 eyes (47%) using EyeCam, and 40 eyes (47%) with goniophotography (P=0.69 in both comparisons, McNemar test). The agreement for angle closure diagnosis (by eye) between gonioscopy and the 2 imaging modalities was high (κ=0.86; 95% Confidence Interval (CI), 0.75-0.97), whereas the agreement between EyeCam and goniophotography was not as good (κ=0.72; 95% CI, 0.57-0.87); largely due to lack of agreement in the nasal and temporal quadrants (κ=0.55 to 0.67). The AUC for detecting eyes with gonioscopic angle closure was similar for goniophotography and EyeCam (AUC 0.93, sensitivity=94.7%, specificity=91.5%; P>0.95). EyeCam and goniophotography have similarly high sensitivity and specificity for the detection of gonioscopic angle closure.
Discriminating anisometropic amblyopia from myopia based on interocular inhibition
Jia, Wuli; Zhou, Jiawei; Lu, Zhong-Lin; Lesmes, Luis A.; Huang, Chang-Bing
2016-01-01
Amblyopia screening during childhood is critical for early detection and successful treatment. In the current study, we develop and evaluate a screening method that exploits the imbalanced interocular inhibition between amblyopic and fellow eyes. In nineteen subjects with anisometropic amblyopia and twenty-two age-matched subjects with myopia, we measured the area under the contrast sensitivity functions (AUCSFs) in eight monocular conditions defined by tested eye (left, right), patching of the untested eye (translucent, opaque), and refractive status (corrected, uncorrected). For each test eye, we defined the inhibition index as the ratio between AUCSF values obtained in the translucent and opaque patching conditions of the untested eye. To evaluate the screening potential of the inhibition index, we compared results from patients with amblyopia and myopia. With and without optical correction, the index was significantly lower in the amblyopic eye than in the fellow eye of the amblyopic subjects and both eyes of the myopic subjects. No significant difference was found among the two eyes of the myopic subjects and the fellow eyes of the amblyopic subjects. With the inhibition index as the predictor, a logistic regression model successfully discriminated amblyopic eyes from myopic eyes with 100% accuracy in the uncorrected condition. In the corrected condition, with the inhibition index and interocular visual acuity difference as predictors, amblyopic eyes were likewise discriminated from myopic eyes with 100% accuracy. This pattern of CSF changes, caused by the different patching modes of the untested eye, provides a potential CSF signature to discriminate anisometropic amblyopia from myopia. PMID:25701741
Kotani, Manato; Shimono, Kohei; Yoneyama, Toshihiro; Nakako, Tomokazu; Matsumoto, Kenji; Ogi, Yuji; Konoike, Naho; Nakamura, Katsuki; Ikeda, Kazuhito
2017-09-01
Eye tracking systems are used to investigate eyes position and gaze patterns presumed as eye contact in humans. Eye contact is a useful biomarker of social communication and known to be deficient in patients with autism spectrum disorders (ASDs). Interestingly, the same eye tracking systems have been used to directly compare face scanning patterns in some non-human primates to those in human. Thus, eye tracking is expected to be a useful translational technique for investigating not only social attention and visual interest, but also the effects of psychiatric drugs, such as oxytocin, a neuropeptide that regulates social behavior. In this study, we report on a newly established method for eye tracking in common marmosets as unique New World primates that, like humans, use eye contact as a mean of communication. Our investigation was aimed at characterizing these primates face scanning patterns and evaluating the effects of oxytocin on their eye contact behavior. We found that normal common marmosets spend more time viewing the eyes region in common marmoset's picture than the mouth region or a scrambled picture. In oxytocin experiment, the change in eyes/face ratio was significantly greater in the oxytocin group than in the vehicle group. Moreover, oxytocin-induced increase in the change in eyes/face ratio was completely blocked by the oxytocin receptor antagonist L-368,899. These results indicate that eye tracking in common marmosets may be useful for evaluating drug candidates targeting psychiatric conditions, especially ASDs. Copyright © 2017 Elsevier Ltd. All rights reserved.
Effect of Donor and Recipient Factors on Corneal Graft Rejection
Stulting, R. Doyle; Sugar, Alan; Beck, Roy; Belin, Michael; Dontchev, Mariya; Feder, Robert S.; Gal, Robin L.; Holland, Edward J.; Kollman, Craig; Mannis, Mark J.; Price, Francis; Stark, Walter; Verdier, David D.
2014-01-01
Purpose To assess the relationship between donor and recipient factors and corneal allograft rejection in eyes that underwent penetrating keratoplasty (PK) in the Cornea Donor Study. Methods 1090 subjects undergoing corneal transplantation for a moderate risk condition (principally Fuchs’ dystrophy or pseudophakic corneal edema) were followed for up to 5 years. Associations of baseline recipient and donor factors with the occurrence of a probable or definite rejection event were assessed in univariate and multivariate proportional hazards models. Results Eyes with pseudophakic or aphakic corneal edema (N=369) were more likely to experience a rejection event than eyes with Fuchs’ dystrophy (N=676) (34% ± 6% versus 22% ± 4%; hazard ratio = 1.56; 95% confidence interval 1.21 to 2.03). Among eyes with Fuchs’dystrophy, a higher probability of a rejection event was observed in phakic post-transplant eyes compared with eyes that underwent cataract extraction with or without intraocular lens implantation during PK (29% vs. 19%; hazard ratio = 0.54; 95% confidence interval 0.36 to 0.82). Female recipients had a higher probability of a rejection event than males (29% vs. 21%; hazard ratio=1.42; 95% confidence interval 1.08 to 1.87), after controlling for the effect of preoperative diagnosis and lens status. Donor age and donor recipient ABO compatibility were not associated with rejection. Conclusions There was a substantially higher graft rejection rate in eyes with pseudophakic or aphakic corneal edema compared with eyes with Fuchs’ dystrophy. Female recipients were more likely to have a rejection event than males. Graft rejection was not associated with donor age. PMID:22488114
Rosman, Mohamad; Hall, Reece C; Chan, Cordelia; Ang, Andy; Koh, Jane; Htoon, Hla Myint; Tan, Donald T H; Mehta, Jodhbir S
2013-07-01
To compare the efficacy, predictability, and refractive outcomes of laser in situ keratomileusis (LASIK) using 2 femtosecond platforms for flap creation. Multisurgeon single center. Clinical trial. Bilateral femtosecond LASIK was performed using the Wavelight Allegretto Eye-Q 400 Hz excimer laser system. The Visumax femtosecond platform (Group 1) was used to create the LASIK flap in 1 eye, while the Intralase femtosecond platform (Group 2) was used to create the LASIK flap in the contralateral eye. The preoperative, 1-month, and 3-month postoperative visual acuities, refraction, and contrast sensitivity in the 2 groups were compared. The study enrolled 45 patients. Three months after femtosecond LASIK, 79.5% of eyes in Group 1 and 82.1% in Group 2 achieved an uncorrected distance visual acuity of 20/20 (P=.808). The mean efficacy index was 0.97 in Group 1 and 0.98 in Group 2 at 3 months (P=.735); 89.7% of eyes in Group 1 and 84.6% of eyes in Group 2 were within ± 0.50 diopter of emmetropia at 3 months (P=.498). No eye in either group lost more than 2 lines of corrected distance visual acuity. The mean safety index at 3 months was 1.11 in Group 1 and 1.10 in Group 2 (P=.570). The results of LASIK with both femtosecond lasers were similar, and both platforms produced efficacious and predictable LASIK outcomes. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Eye bank tissue utilization between endothelial keratoplasty and penetrating keratoplasty.
Croasdale, Christopher R; Barney, Erin; Warner, Evan J
2013-03-01
To determine rates of tissue use for corneal transplants via endothelial keratoplasty (EK) relative to penetrating keratoplasty (PK). Retrospective chart review of all cornea tissues (n = 3669) distributed from the Lions Eye Bank of Wisconsin for EK or PK from August 1, 2004 through July 31, 2009 (60 months). Rates of tissue use for EK relative to PK were determined both on a yearly basis and for the overall study period. Replacement frequency and time to subsequent surgery were established for each group. Donor tissue and recipient characteristics were compared between groups. Donor characteristics did not differ between the 2 groups; 11.9% of EK tissues failed and were replaced during the study period compared with 5.1% of PK tissues (P < 0.0001). Additional tissue for the same eye came at a mean of 174 days after an EK surgery compared with 558 days after a PK (P < 0.0001). Surgeons requesting tissue for EK increased each year, whereas the number of repeat tissue requests decreased over time. Additional tissues were required for recipients of EK more than twice as often as for recipients of PK, and replacement of EK grafts occurred at a mean of more than 1 year before replacement of PK grafts. This pattern of tissue utilization during the first 5 years of distribution for EK did not negatively affect the Lions Eye Bank of Wisconsin from meeting the surgeon demand for tissue in its service area. Eye banks may wish to monitor tissue utilization as part of their quality assurance program.
Rao, Harsha L; Yadav, Ravi K; Addepalli, Uday K; Begum, Viquar U; Senthil, Sirisha; Choudhari, Nikhil S; Garudadri, Chandra S
2015-08-01
To evaluate the relationship between the reference standard used to diagnose glaucoma and the diagnostic ability of spectral domain optical coherence tomograph (SDOCT). In a cross-sectional study, 280 eyes of 175 consecutive subjects, referred to a tertiary eye care center for glaucoma evaluation, underwent optic disc photography, visual field (VF) examination, and SDOCT examination. The cohort was divided into glaucoma and control groups based on 3 reference standards for glaucoma diagnosis: first based on the optic disc classification (179 glaucoma and 101 control eyes), second on VF classification (glaucoma hemifield test outside normal limits and pattern SD with P-value of <5%, 130 glaucoma and 150 control eyes), and third on the presence of both glaucomatous optic disc and glaucomatous VF (125 glaucoma and 155 control eyes). Relationship between the reference standards and the diagnostic parameters of SDOCT were evaluated using areas under the receiver operating characteristic curve, sensitivity, and specificity. Areas under the receiver operating characteristic curve and sensitivities of most of the SDOCT parameters obtained with the 3 reference standards (ranging from 0.74 to 0.88 and 72% to 88%, respectively) were comparable (P>0.05). However, specificities of SDOCT parameters were significantly greater (P<0.05) with optic disc classification as reference standard (74% to 88%) compared with VF classification as reference standard (57% to 74%). Diagnostic parameters of SDOCT that was significantly affected by reference standard was the specificity, which was greater with optic disc classification as the reference standard. This has to be considered when comparing the diagnostic ability of SDOCT across studies.
Yang, Hongli; Downs, J. Crawford; Burgoyne, Claude F.
2009-01-01
Purpose To characterize physiologic inter-eye differences in optic nerve head (ONH) architecture within six normal rhesus monkeys and compare them to inter-eye differences within three previously-reported cynomolgus monkeys with early experimental glaucoma (EEG). Methods Trephinated ONH and peripapillary sclera from both eyes of six normal monkeys were serial sectioned, 3D reconstructed, 3D delineated and parameterized. For each normal animal, and each parameter, physiologic inter-eye difference (PID) was calculated (both overall and regionally) by converting all OS data to OD configuration and subtracting the OS from the OD value and Physiologic Inter-eye Percent Difference (PIPD) was calculated as the PID divided by the measurement mean of the two eyes. For each EEG monkey, inter-eye (EEG minus normal) differences and percent differences for each parameter overall and regionally were compared to the PID and PIPD Maximums. Results For all parameters the PID Maximums were relatively small overall. Compared to overall PID maximums, overall inter-eye differences in EEG monkeys were greatest for laminar deformation and thickening, posterior scleral canal enlargement, cupping and prelaminar neural tissue thickening. Compared to the regional PID Maximums, the lamina cribrosa was posteriorly deformed centrally, inferiorly, inferonasally and superiorly and was thickened centrally. The prelaminar neural tissues were thickened inferiorly, inferonasally and superiorly. Conclusion These data provide the first characterization of PID/PIPD maximums for ONH neural and connective tissue parameters in normal monkeys and serve to further clarify the location and character of early ONH change in experimental glaucoma. However, because of the species differences, the findings in EEG need to be confirmed within EEG rhesus monkey eyes. PMID:18775866
Mostafaei, A; Sedgipour, M R; Sadeghi-Bazargani, H
2009-12-01
Study purpose was to compare the changes of Visual Field (VF) during laser in situ Keratomileusis (LASIK) VS photorefractive keratectomy (PRK). This randomized, double blind, study involved 54 eyes of 27 Myopia patients who underwent LASIK or PRK procedures for contralateral eyes in each patient. Using Humphrey 30-2 SITA standard, the Mean Defect (MD) and Pattern Standard Deviation (PSD) were evaluated preoperatively and three months after surgery. At the same examination optical zone size, papillary and corneal diameters were also evaluated. There was no clinically significant difference in PSD and MD measurements between treated eyes with LASIK or PRK in any zone pre and postoperatively. VF may not be affected by corneal changes induced by LASIK or PRK three months after surgery.
The fate of the oculomotor system in clinical bilateral anophthalmia.
Bridge, Holly; Ragge, Nicola; Jenkinson, Ned; Cowey, Alan; Watkins, Kate E
2012-05-01
The interdependence of the development of the eye and oculomotor system during embryogenesis is currently unclear. The occurrence of clinical anophthalmia, where the globe fails to develop, permits us to study the effects this has on the development of the complex neuromuscular system controlling eye movements. In this study, we use very high-resolution T2-weighted imaging in five anophthalmic subjects to visualize the extraocular muscles and the cranial nerves that innervate them. The subjects differed in the presence or absence of the optic nerve, the abducens nerve, and the extraocular muscles, reflecting differences in the underlying disruption to the eye's morphogenetic pathway. The oculomotor nerve was present in all anophthalmic subjects and only slightly reduced in size compared to measurements in sighted controls. As might be expected, the presence of rudimentary eye-like structures in the socket appeared to correlate with development and persistence of the extraocular muscles in some cases. Our study supports in part the concept of an initial independence of muscle development, with its maintenance subject to the presence of these eye-like structures.
Reliability of Corneal Dynamic Scheimpflug Analyser Measurements in Virgin and Post-PRK Eyes
Chen, Xiangjun; Stojanovic, Aleksandar; Hua, Yanjun; Eidet, Jon Roger; Hu, Di; Wang, Jingting; Utheim, Tor Paaske
2014-01-01
Purpose To determine the measurement reliability of CorVis ST, a dynamic Scheimpflug analyser, in virgin and post-photorefractive keratectomy (PRK) eyes and compare the results between these two groups. Methods Forty virgin eyes and 42 post-PRK eyes underwent CorVis ST measurements performed by two technicians. Repeatability was evaluated by comparing three consecutive measurements by technician A. Reproducibility was determined by comparing the first measurement by technician A with one performed by technician B. Intraobserver and interobserver intraclass correlation coefficients (ICCs) were calculated. Univariate analysis of covariance (ANCOVA) was used to compare measured parameters between virgin and post-PRK eyes. Results The intraocular pressure (IOP), central corneal thickness (CCT) and 1st applanation time demonstrated good intraobserver repeatability and interobserver reproducibility (ICC≧0.90) in virgin and post-PRK eyes. The deformation amplitude showed a good or close to good repeatability and reproducibility in both groups (ICC≧0.88). The CCT correlated positively with 1st applanation time (r = 0.437 and 0.483, respectively, p<0.05) and negatively with deformation amplitude (r = −0.384 and −0.375, respectively, p<0.05) in both groups. Compared to post-PRK eyes, virgin eyes showed longer 1st applanation time (7.29±0.21 vs. 6.96±0.17 ms, p<0.05) and lower deformation amplitude (1.06±0.07 vs. 1.17±0.08 mm, p<0.05). Conclusions CorVis ST demonstrated reliable measurements for CCT, IOP, and 1st applanation time, as well as relatively reliable measurement for deformation amplitude in both virgin and post-PRK eyes. There were differences in 1st applanation time and deformation amplitude between virgin and post-PRK eyes, which may reflect corneal biomechanical changes occurring after the surgery in the latter. PMID:25302580
Denoyer, Alexandre; Landman, Elise; Trinh, Liem; Faure, Jean-François; Auclin, François; Baudouin, Christophe
2015-04-01
To compare small incision lenticule extraction (SMILE) versus LASIK for post-refractive dry eye disease. Prospective, comparative, nonrandomized clinical study. Thirty patients scheduled for bilateral myopic SMILE and 30 age-, sex-, and refraction-matched patients scheduled for bilateral myopic LASIK were enrolled and followed for 6 months after the surgery. Complete evaluation of dry eye disease was performed at 1 and 6 months postoperatively, which included vision-related quality of life (Ocular Surface Disease Index [OSDI]), clinical examinations (tear film breakup time [TBUT], Schirmer I test, corneal staining), and tear osmolarity measurements, together with an overall severity score. Function and morphology of the corneal innervation were evaluated by corneal esthesiometry and subbasal nerve imaging using in vivo confocal microscopy (IVCM). Overall analysis of dry eye disease and corneal innervation. High incidence of mild to moderate dry eye disease was observed in both groups 1 month postoperatively, which remained significantly higher in the LASIK group than in the SMILE group 6 months after surgery (overall severity score [0-4]: 1.2±1.1 vs. 0.2±0.4, respectively, P < 0.01), leading to more frequent use of tear substitutes over the long term. Corneal sensitivity was better in SMILE than in LASIK eyes 1 month postoperatively (3.5±1.79 vs. 2.45±2.48, respectively, P < 0.01) and then recovered to statistically similar values at 6 months. Corneal nerve density, number of long fibers, and branchings as assessed by IVCM were significantly higher in the SMILE group compared with the LASIK group 1 and 6 months after surgery. Corneal sensitivity was negatively correlated with dry eye-related corneal damage (R² = 0.48, P < 0.01), and the long fiber nerve density was independently correlated with the OSDI score (R² = 0.50, P < 0.01) and the Schirmer test (R² = 0.21, P < 0.01) 6 months postoperatively. The SMILE procedure has a less pronounced impact on the ocular surface and corneal innervation compared with LASIK, further reducing the incidence of dry eye disease and subsequent degradation in quality of life after refractive surgery. Copyright © 2015 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Hura, Arjan S; Osher, Robert H
2017-07-01
To compare the alignment meridian generated by the Zeiss Callisto Eye (Carl Zeiss AG, Dublin, CA) and the Alcon Verion Image Guided System (Alcon Laboratories, Inc., Fort Worth, TX). In this retrospective comparative evaluation of technology, intraoperative images were captured at different steps in the same surgery, allowing the comparison of the guidance lines generated by the Verion system to the parallel guidance lines generated by the Callisto Eye system. Measurements of each hemi-meridian were quantified using Adobe Photoshop 2015 CC software (Adobe Systems, San Jose, CA). The numbers of degrees separating these alignment meridians were calculated, entered into a database, and analyzed. The authors found that of 98 captured images of 16 eyes, the two technologies were identical in 0 eyes (θ 1 = θ 2 = 0), similar by 3° in 52 (53%) captured images (θ 1 ≠ θ 2 ≠ 0), and different by at least 3° in 46 (47%) captured images (θ 1 ≠ θ 2 ≠ 0). The target meridians were superimposed, the target lines were minimally separated, and the target lines were dissimilar. It was noted that some intraoperative variation occurred from measurement to measurement. Within the small group of 16 cases of routine toric lens implantation in this study, the absolute average number of degrees of misalignment between the Verion and Callisto Eye systems was 3.355 for θ 1 and 3.838 for θ 2 . On average, the intraoperative variation termed "drift" was noted to be 3.963° for θ 1 , and 4.557° for θ 2 . The authors found that small deviations were frequent when comparing two sophisticated technologies. Although deviations greater than 3° occurred in less than 47% of captured images from 16 eyes, smaller but significant variations of less than 3° occurred in 53% of captured images from 16 eyes. It was rare to identify a large deviation. However, the authors identified "drift" in the same eye when measurements were taken at different times. The results indicate that the two systems are not currently interchangeable. Superiority of one system over the other was not determined. [J Refract Surg. 2017;33(7):482-487.]. Copyright 2017, SLACK Incorporated.
Hedayatfar, Alireza; Hashemi, Hassan; Asgari, Soheila; Chee, Soon-Phaik
2014-04-01
The aim of this study was to compare the antiinflammatory effect and ocular surface toxicity of topical nonpreserved methylprednisolone sodium succinate 1% and preserved prednisolone acetate suspension 1% for the management of acute anterior uveitis (AAU). In this prospective, randomized, investigator-masked, comparative clinical trial, patients with mild-to-moderate noninfectious AAU were assigned randomly to receive either hourly nonpreserved methylprednisolone 1% (group A) or preserved prednisolone 1% (group B) eye drops followed by a 2-week tapering regimen. Anterior chamber cells and flare were clinically evaluated for the objective comparison of the antiinflammatory effect. The main outcome measure was the percentage of patients with a resolution of inflammation (anterior chamber cells <1+) on day 14. Ocular surface toxicity was assessed by means of the corneal fluorescein staining score, tear breakup time, Schirmer I test, and questionnaire-based grading of ocular discomfort parameters. Seventy-two eyes of 68 patients were studied, of which 38 eyes were enrolled in group A and 34 eyes were enrolled in group B. On day 14, 76.3% of the patients in group A had resolution of inflammation compared with 70.6% of the patients in group B, proving noninferiority (χ = 0.303, P = 0.582). The mean anterior chamber cell grade reduction for patients in group A was similar to that in group B (2.52 vs. 2.86, respectively; P = 0.92). Group A patients showed significantly lower corneal fluorescein staining scores (P < 0.001) and reported milder subjective ocular discomfort (0.55 vs. 1.43, P = 0.01) as compared with group B. Both preparations demonstrated equal antiinflammatory effects for the treatment of AAU. Nonpreserved methylprednisolone eye drops exhibited a significantly lower ocular surface toxicity profile and milder subjective discomfort when compared with that exhibited by preserved prednisolone.
Johnston, Robert L; Carius, Hans-Joachim; Skelly, Adrian; Ferreira, Alberto; Milnes, Fran; Mitchell, Paul
2017-03-01
Neovascular age-related macular degeneration (nAMD) is the leading cause of vision loss among persons aged 65 years and older. Anti-vascular endothelial growth factor (anti-VEGF) treatment is the recommended standard of care. The current study compares the effectiveness of ranibizumab in routine clinical practice in two countries that generally apply two different treatment regimens, treat-and-extend (T&E) in Australia or pro re nata (PRN) in the UK. This retrospective, comparative, non-randomised cohort study is based on patients' data from electronic medical record (EMR) databases in Australia and the UK. Treatment regimens were defined based on location, with Australia as a proxy for analysing T&E and UK as a proxy for analysing PRN. The study included patients with a diagnosis of nAMD who started treatment with ranibizumab between January 2009 and July 2014. A total of 647 eyes of 570 patients in Australia and 3187 eyes of 2755 patients in the UK with complete 12-months follow-up were analysed. Baseline patient characteristics were comparable between the two cohorts. After 1 year of treatment, T&E-treated eyes achieved higher mean (±SE) visual acuity (VA) gains (5.00 ± 0.54 letters [95% confidence interval (CI) 3.93-6.06]) than PRN-treated eyes [3.04 ± 0.24 letters (95% CI 2.57-3.51); difference in means 2.07 ± 0.69 (95% CI 0.73-3.41), p < 0.001]. Non-inferiority of T&E compared to PRN was concluded based on the change in mean visual acuity gains at 12 months. Over the 12-month follow-up, T&E-treated eyes received a higher mean [±standard deviation (SD)] number of injections (9.29 ± 2.43) than PRN-treated eyes (6.04 ± 2.19) (p < 0.0001). Australian patients had a lower mean (±SD) number of total clinic visits (10.29 ± 2.90) than UK patients (11.47 ± 2.93) (p < 0.0001). The higher injection frequency in the T&E cohort may account for the trend toward improved vision. Novartis Pharma AG, Basel, Switzerland.
Jain, Piyush; Kothari, Mihir T; Gode, Vaibhav
2016-10-01
The aim of this study was to compare the results of enhanced Brückner test (EBT) performed by a pediatrician and an experienced pediatric ophthalmologist. In this prospective double-masked cohort study, a pediatrician and a pediatric ophthalmologist performed the EBT in a classroom of a school in semi-dark lighting condition using a direct ophthalmoscope. The results of the test were compared using 2 × 2 Bayesian table and kappa statistics. The findings of the pediatric ophthalmologists were considered gold standard. Two hundred and thirty-six eyes of 118 subjects, mean age 6.8 ± 0.5 years (range, 5.4-7.8 years), were examined. The time taken to complete this test was <10 s per subject. The ophthalmologist identified 59 eyes as ametropic (12 hyperopic and 47 myopic eyes) and 177 as emmetropic compared to 61 eyes as ametropic and 175 emmetropic by pediatrician. The prevalence of the test positive was 25.9%. The sensitivity of the pediatrician was 90.2%, specificity was 97.7%, predictive value of the positive test was 93.2%, and predictive value of the negative test was 96.6%. The clinical agreement (kappa) between the pediatric ophthalmologist and the pediatrician was 0.9. The results of the EBT performed by pediatrician were comparable to that of an experienced pediatric ophthalmologist. Opportunistic screening of refractive errors using EBT by a pediatrician can be an important approach in the detection of ametropia in children.
Silvey, Garry M.; Macri, Jennifer M.; Lee, Paul P.; Lobach, David F.
2005-01-01
New mobile computing devices including personal digital assistants (PDAs) and tablet computers have emerged to facilitate data collection at the point of care. Unfortunately, little research has been reported regarding which device is optimal for a given care setting. In this study we created and compared functionally identical applications on a Palm operating system-based PDA and a Windows-based tablet computer for point-of-care documentation of clinical observations by eye care professionals when caring for patients with diabetes. Eye-care professionals compared the devices through focus group sessions and through validated usability surveys. We found that the application on the tablet computer was preferred over the PDA for documenting the complex data related to eye care. Our findings suggest that the selection of a mobile computing platform depends on the amount and complexity of the data to be entered; the tablet computer functions better for high volume, complex data entry, and the PDA, for low volume, simple data entry. PMID:16779128
Differentially-expressed opsin genes identified in Sinocyclocheilus cavefish endemic to China
Meng, Fanwei; Zhao, Yahui; Postlethwait, John H.; Zhang, Chunguang
2013-01-01
Eye degeneration is a common troglomorphic character of cave-dwelling organisms. Comparing the morphology and molecular biology of cave species and their close surface relatives is a powerful tool for studying regressive eye evolution and other adaptive phenotypes. We compared two co-occurring and closely-related species of the fish genus Sinocyclocheilus, which is endemic to China and includes both surface- and cave-dwelling species. Sinocyclocheilus tileihornes, a cave species, had smaller eyes than Sinocyclocheilus angustiporus, a surface species. Histological and immunohistochemical analyses revealed that the cavefish had shorter cones and more disorderly rods than did the surface-dwelling species. Using quantitative PCR and in situ hybridization, we found that rhodopsin and a long-wavelength sensitive opsin had significantly lower expression levels in the cavefish. Furthermore, one of two short-wavelength-sensitive opsins was expressed at significantly higher levels in the cavefish. Changes in the expression of opsin genes may have played a role in the degeneration of cavefish eyes PMID:24363664
NASA Technical Reports Server (NTRS)
Dick, A. O.; Brown, J. L.; Bailey, G.
1977-01-01
Two different types of analyses were done on data from a study in which eye movements and other variables were recorded while four pilots executed landing sequences in a Boeing 737 simulation. Various conditions were manupulated, including changes in turbulence, starting position, and instrumentation. Control inputs were analyzed in the context of the various conditions and compared against ratings of workload obtained using the Cooper-Harper scale. A number of eye-scanning measures including mean dwell time and transition from one instrument to another were entered into a principal components factor analysis. The results show a differentiation between control inputs and eye-scanning behavior. This shows the need for improved definition of workload and experiments to uncover the important differences among control inputs, eye-scanning and cognitive processes of the pilot.
Punctal occlusion for dry eye syndrome.
Ervin, Ann-Margret; Law, Andrew; Pucker, Andrew D
2017-06-26
Dry eye syndrome is a disorder of the tear film that is associated with symptoms of ocular discomfort. Punctal occlusion is a mechanical treatment that blocks the tear drainage system in order to aid in the preservation of natural tears on the ocular surface. To assess the effects of punctal plugs versus no punctal plugs, different types of punctal plugs, and other interventions for managing dry eye. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (which contains the Cochrane Eyes and Vision Trials Register) (2016, Issue 11), MEDLINE Ovid (1946 to 8 December 2016), Embase.com (1947 to 8 December 2016), PubMed (1948 to 8 December 2016), LILACS (Latin American and Caribbean Health Sciences Literature Database) (1982 to 8 December 2016), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com; last searched 18 November 2012 - this resource is now archived), ClinicalTrials.gov (www.clinicaltrials.gov; searched 8 December 2016), and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en; searched 8 December 2016). We did not use any date or language restrictions in the electronic searches for trials. We also searched the Science Citation Index-Expanded database and reference lists of included studies. The evidence was last updated on 8 December 2016 SELECTION CRITERIA: We included randomized and quasi-randomized controlled trials of collagen or silicone punctal plugs in symptomatic participants diagnosed with aqueous tear deficiency or dry eye syndrome. Two review authors independently assessed trial quality and extracted data. We contacted study investigators for additional information when needed. We included 18 trials (711 participants, 1249 eyes) from Austria, Canada, China, Greece, Japan, Mexico, Netherlands, Turkey, the UK, and the USA in this review. We also identified one ongoing trial. Overall we judged these trials to be at unclear risk of bias because they were poorly reported. We assessed the evidence for eight comparisons.Five trials compared punctal plugs with no punctal plugs (control). Three of these trials employed a sham treatment and two trials observed the control group. Two trials did not report outcome data relevant to this review. There was very low-certainty evidence on symptomatic improvement. The three trials that reported this outcome used different scales to measure symptoms. In all three trials, there was little or no improvement in symptom scores with punctal plugs compared with no punctal plugs. Low-certainty evidence from one trial suggested less ocular surface staining in the punctal plug group compared with the no punctal plug group however this difference was small and possibly clinically unimportant (mean difference (MD) in fluorescein staining score -1.50 points, 95% CI -1.88 to -1.12; eyes = 61). Similarly there was a small difference in tear film stability with people in the punctal plug group having more stability (MD 1.93 seconds more, 95% CI 0.67 to 3.20; eyes = 28, low-certainty evidence). The number of artificial tear applications was lower in the punctal plug group compared with the no punctal plugs group in one trial (MD -2.70 applications, 95% CI -3.11 to -2.29; eyes = 61, low-certainty evidence). One trial with low-certainty evidence reported little or no difference between the groups in Schirmer scores, but did not report any quantitative data on aqueous tear production. Very low-certainty evidence on adverse events suggested that events occurred reasonably frequently in the punctal plug group and included epiphora, itching, tenderness and swelling of lids with mucous discharge, and plug displacement.One trial compared punctal plugs with cyclosporine (20 eyes) and one trial compared punctal plugs with oral pilocarpine (55 eyes). The evidence was judged to be very low-certainty due to a combination of risk of bias and imprecision.Five trials compared punctal plugs with artificial tears. In one of the trials punctal plugs was combined with artificial tears and compared with artificial tears alone. There was very low-certainty evidence on symptomatic improvement. Low-certainty evidence of little or no improvement in ocular surface staining comparing punctal plugs with artificial tears (MD right eye 0.10 points higher, 0.56 lower to 0.76 higher, MD left eye 0.60 points higher, 0.10 to 1.10 higher) and low-certainty evidence of little or no difference in aqueous tear production (MD 0.00 mm/5 min, 0.33 lower to 0.33 higher)Three trials compared punctal plugs in the upper versus the lower puncta, and none of them reported the review outcomes at long-term follow-up. One trial with very low-certainty evidence reported no observed complications, but it was unclear which complications were collected.One trial compared acrylic punctal plugs with silicone punctal plugs and the trial reported outcomes at approximately 11 weeks of follow-up (36 eyes). The evidence was judged to be very low-certainty due to a combination of risk of bias and imprecision.One trial compared intracanalicular punctal plugs with silicone punctal plugs at three months follow-up (57 eyes). The evidence was judged to be very low-certainty due to a combination of risk of bias and imprecision.Finally, two trials with very low-certainty evidence compared collagen punctal plugs versus silicone punctal plugs (98 eyes). The evidence was judged to be very low-certainty due to a combination of risk of bias and imprecision. Although the investigators of the individual trials concluded that punctal plugs are an effective means for treating dry eye signs and symptoms, the evidence in this systematic review suggests that improvements in symptoms and commonly tested dry eye signs are inconclusive. Despite the inclusion of 11 additional trials, the findings of this updated review are consistent with the previous review published in 2010. The type of punctal plug investigated, the type and severity of dry eye being treated, and heterogeneity in trial methodology confounds our ability to make decisive statements regarding the effectiveness of punctal plug use. Although punctal plugs are believed to be relatively safe, their use is commonly associated with epiphora and, less commonly, with inflammatory conditions such as dacryocystitis.
Punctal occlusion for dry eye syndrome
Ervin, Ann-Margret; Law, Andrew; Pucker, Andrew D
2017-01-01
Background Dry eye syndrome is a disorder of the tear film that is associated with symptoms of ocular discomfort. Punctal occlusion is a mechanical treatment that blocks the tear drainage system in order to aid in the preservation of natural tears on the ocular surface. Objectives To assess the effects of punctal plugs versus no punctal plugs, different types of punctal plugs, and other interventions for managing dry eye. Search methods We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (which contains the Cochrane Eyes and Vision Trials Register) (2016, Issue 11), MEDLINE Ovid (1946 to 8 December 2016), Embase.com (1947 to 8 December 2016), PubMed (1948 to 8 December 2016), LILACS (Latin American and Caribbean Health Sciences Literature Database) (1982 to 8 December 2016), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com; last searched 18 November 2012 - this resource is now archived), ClinicalTrials.gov (www.clinicaltrials.gov; searched 8 December 2016), and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en; searched 8 December 2016). We did not use any date or language restrictions in the electronic searches for trials. We also searched the Science Citation Index-Expanded database and reference lists of included studies. The evidence was last updated on 8 December 2016 Selection criteria We included randomized and quasi-randomized controlled trials of collagen or silicone punctal plugs in symptomatic participants diagnosed with aqueous tear deficiency or dry eye syndrome. Data collection and analysis Two review authors independently assessed trial quality and extracted data. We contacted study investigators for additional information when needed. Main results We included 18 trials (711 participants, 1249 eyes) from Austria, Canada, China, Greece, Japan, Mexico, Netherlands, Turkey, the UK, and the USA in this review. We also identified one ongoing trial. Overall we judged these trials to be at unclear risk of bias because they were poorly reported. We assessed the evidence for eight comparisons. Five trials compared punctal plugs with no punctal plugs (control). Three of these trials employed a sham treatment and two trials observed the control group. Two trials did not report outcome data relevant to this review. There was very low-certainty evidence on symptomatic improvement. The three trials that reported this outcome used different scales to measure symptoms. In all three trials, there was little or no improvement in symptom scores with punctal plugs compared with no punctal plugs. Low-certainty evidence from one trial suggested less ocular surface staining in the punctal plug group compared with the no punctal plug group however this difference was small and possibly clinically unimportant (mean difference (MD) in fluorescein staining score -1.50 points, 95% CI -1.88 to -1.12; eyes = 61). Similarly there was a small difference in tear film stability with people in the punctal plug group having more stability (MD 1.93 seconds more, 95% CI 0.67 to 3.20; eyes = 28, low-certainty evidence). The number of artificial tear applications was lower in the punctal plug group compared with the no punctal plugs group in one trial (MD -2.70 applications, 95% CI -3.11 to -2.29; eyes = 61, low-certainty evidence). One trial with low-certainty evidence reported little or no difference between the groups in Schirmer scores, but did not report any quantitative data on aqueous tear production. Very low-certainty evidence on adverse events suggested that events occurred reasonably frequently in the punctal plug group and included epiphora, itching, tenderness and swelling of lids with mucous discharge, and plug displacement. One trial compared punctal plugs with cyclosporine (20 eyes) and one trial compared punctal plugs with oral pilocarpine (55 eyes). The evidence was judged to be very low-certainty due to a combination of risk of bias and imprecision. Five trials compared punctal plugs with artificial tears. In one of the trials punctal plugs was combined with artificial tears and compared with artificial tears alone. There was very low-certainty evidence on symptomatic improvement. Low-certainty evidence of little or no improvement in ocular surface staining comparing punctal plugs with artificial tears (MD right eye 0.10 points higher, 0.56 lower to 0.76 higher, MD left eye 0.60 points higher, 0.10 to 1.10 higher) and low-certainty evidence of little or no difference in aqueous tear production (MD 0.00 mm/5 min, 0.33 lower to 0.33 higher) Three trials compared punctal plugs in the upper versus the lower puncta, and none of them reported the review outcomes at long-term follow-up. One trial with very low-certainty evidence reported no observed complications, but it was unclear which complications were collected. One trial compared acrylic punctal plugs with silicone punctal plugs and the trial reported outcomes at approximately 11 weeks of follow-up (36 eyes). The evidence was judged to be very low-certainty due to a combination of risk of bias and imprecision. One trial compared intracanalicular punctal plugs with silicone punctal plugs at three months follow-up (57 eyes). The evidence was judged to be very low-certainty due to a combination of risk of bias and imprecision. Finally, two trials with very low-certainty evidence compared collagen punctal plugs versus silicone punctal plugs (98 eyes). The evidence was judged to be very low-certainty due to a combination of risk of bias and imprecision. Authors' conclusions Although the investigators of the individual trials concluded that punctal plugs are an effective means for treating dry eye signs and symptoms, the evidence in this systematic review suggests that improvements in symptoms and commonly tested dry eye signs are inconclusive. Despite the inclusion of 11 additional trials, the findings of this updated review are consistent with the previous review published in 2010. The type of punctal plug investigated, the type and severity of dry eye being treated, and heterogeneity in trial methodology confounds our ability to make decisive statements regarding the effectiveness of punctal plug use. Although punctal plugs are believed to be relatively safe, their use is commonly associated with epiphora and, less commonly, with inflammatory conditions such as dacryocystitis. PMID:28649802
Neurostimulation of the Lacrimal Nerve for Enhanced Tear Production
Kossler, Andrea L.; Wang, Jianhua; Feuer, William; Tse, David T.
2014-01-01
Purpose To design a proof-of-concept study to assess the effect of lacrimal nerve stimulation (LNS) with an implantable pulse generator (IPG) to increase aqueous tear production. Methods Experimental animal study design of six Dutch Belted rabbits. Ultra high-resolution optical coherence tomography (UHR-OCT) quantified tear production by measuring the baseline tear volume of each rabbit’s right and left eye. A neurostimulator was implanted adjacent to the right lacrimal nerve. After two minutes of LNS (100 μs, 1.6 mAmp, 20 Hz, 5–8 volts), the tear volumes were measured with UHR-OCT. The change in tear volume was quantified and compared to the non-stimulated left eye. Three rabbits underwent chronic LNS (100 μS, 1.6 mAmp, 10 Hz, 2 volts) and their lacrimal glands were harvested for histopathologic analysis. Results UHR-OCT imaging of the right eyes tear volume showed a 441% average increase in tear production after LNS as a percent of baseline. After stimulation, right eyes had statistically significant greater increase in tear volumes than left eyes (p=0.028, Wilcoxon test). Post-stimulation right eye tear volumes were significantly greater compared to baseline (p=0.028, Wilcoxon test). Histopathologic examination of the lacrimal glands showed no discernible tissue damage from chronic neurostimulation. Additionally, there were no gross adverse effects on the general well-beings of the animals due to chronic stimulation. Conclusions Lacrimal nerve stimulation with an implantable pulse generator appears to increase aqueous tear production. Chronic LNS showed no histopathologic lacrimal gland damage. This study suggests LNS is a promising new treatment strategy to increase aqueous tear production. PMID:25126767
Little, Erika; Yvorchuk-St Jean, Kathy; Little, William; Sithole, Fortune; St Jean, Guy
2016-10-01
Oxybuprocaine hydrochloride ophthalmic solution has been widely used off-label in horses and donkeys, despite lack of data demonstrating efficacy and safety in these species. The objective of this study was to assess anesthetic efficacy of 0.4% oxybuprocaine hydrochloride ophthalmic solution in horses ( n = 5) and donkeys ( n = 24) and compare the effects with 0.5% proparacaine hydrochloride ophthalmic solution. The baseline corneal touch threshold (CTT) was measured with a Cochet-Bonnet esthesiometer. Donkeys ( n = 12) and horses ( n = 5) in group A received sterile ophthalmic solutions 0.4% oxybuprocaine with fluorescein (also termed benoxinate with fluorescein, abbreviated as ben + flu) instilled in one eye and 0.9% sterile sodium chloride solution (NaCl) with fluorescein (Na + flu) in the contralateral eye. Donkeys ( n = 12) and horses ( n = 5) in group B received sterile ophthalmic solutions (ben + flu) in one eye and 0.5% proparacaine with fluorescein (prop + flu) in the contralateral eye. The CTT was measured at 1 and 5 min post-application and at 5-minute intervals until 75 min after treatment. The CTT changes over time differed significantly between oxybuprocaine-treated and control eyes ( P < 0.001). The CTT continued to decrease throughout the duration of the study when compared with baseline values. No statistically significant difference in onset, depth, or duration of corneal anesthesia was found between oxybuprocaine and proparacaine treated eyes during the time of the study. Interestingly, horses were shown to have a significantly more sensitive cornea than donkeys ( P = 0.002). Oxybuprocaine and proparacaine reduced corneal sensitivity in donkeys and horses. No local irritation was observed with 0.4% oxybuprocaine.
Little, Erika; Yvorchuk-St. Jean, Kathy; Little, William; Sithole, Fortune; St. Jean, Guy
2016-01-01
Oxybuprocaine hydrochloride ophthalmic solution has been widely used off-label in horses and donkeys, despite lack of data demonstrating efficacy and safety in these species. The objective of this study was to assess anesthetic efficacy of 0.4% oxybuprocaine hydrochloride ophthalmic solution in horses (n = 5) and donkeys (n = 24) and compare the effects with 0.5% proparacaine hydrochloride ophthalmic solution. The baseline corneal touch threshold (CTT) was measured with a Cochet-Bonnet esthesiometer. Donkeys (n = 12) and horses (n = 5) in group A received sterile ophthalmic solutions 0.4% oxybuprocaine with fluorescein (also termed benoxinate with fluorescein, abbreviated as ben + flu) instilled in one eye and 0.9% sterile sodium chloride solution (NaCl) with fluorescein (Na + flu) in the contralateral eye. Donkeys (n = 12) and horses (n = 5) in group B received sterile ophthalmic solutions (ben + flu) in one eye and 0.5% proparacaine with fluorescein (prop + flu) in the contralateral eye. The CTT was measured at 1 and 5 min post-application and at 5-minute intervals until 75 min after treatment. The CTT changes over time differed significantly between oxybuprocaine-treated and control eyes (P < 0.001). The CTT continued to decrease throughout the duration of the study when compared with baseline values. No statistically significant difference in onset, depth, or duration of corneal anesthesia was found between oxybuprocaine and proparacaine treated eyes during the time of the study. Interestingly, horses were shown to have a significantly more sensitive cornea than donkeys (P = 0.002). Oxybuprocaine and proparacaine reduced corneal sensitivity in donkeys and horses. No local irritation was observed with 0.4% oxybuprocaine. PMID:27733789
Wong, D; Kumar, I; Quah, S A; Ali, H; Valldeperas, X; Valdeperas, X; Romano, M R
2009-01-01
A solution of perfluorohexyloctane and silicone oil with a specific gravity of 1.06 g/cm(3) (Densiron-68) has similar properties as conventional silicone oil (SO) in terms of the shape of the bubble and its ability to act as an internal tamponade agent. We conducted a case-control study to compare the postoperative intraocular pressure (IOP) in patients treated with Densiron-68 with those treated with SO. Seventy-one eyes of 71 patients and 57 eyes of 57 patients who had received Densiron-68 and SO, respectively, were included in our study. Both groups were found to have matched for their preoperative comorbidities (diabetes, glaucoma, phakic status, and refractive errors). IOP at first day, between seventh and fourteenth day, and at 4 week postoperatively was recorded. The mean IOP was higher in patients treated with Densiron-68 at day 1 and between seventh and fourteenth day postoperatively (P=0.05 and 0.01, respectively). By the 4th week, the IOP difference between the two groups was insignificant (P=0.17). The difference in the two groups could still be clinically significant and the raised IOP in Densiron-68 group was more difficult to treat in some cases.On day 1, nine eyes (12.7%) in the Densiron-68 group and two eyes (3.5%) in the SO group had IOP greater than 30 mmHg. At 4 weeks, IOP of more than 30 mmHg was seen in nine eyes (12.7%) in the Densiron-68-treated group and in one eye (1.8%) in the SO group. The use of Densiron-68 was associated with a higher IOP in the early postoperative period when compared with SO.
Ohno-Matsui, Kyoko
Pathologic myopia (PM) is the only myopia that causes the loss of best-corrected visual acuity. The main reason for best-corrected visual acuity loss is complications specific to PM, such as myopic maculopathy, myopic traction maculopathy, and myopic optic neuropathy (or glaucoma). The meta-analyses of the PM study group (META-PM study) made a classification system for myopic maculopathy. On the basis of this study, PM has been defined as eyes having atrophic changes equal to or more severe than diffuse atrophy. Posterior staphyloma and eye deformity are important causes of developing vision-threatening complications. Posterior staphyloma is unique to PM, except for inferior staphyloma due to tilted disc syndrome. It is defined as an outpouching of the wall of the eye that has a radius of curvature that is less than the surrounding curvature of the wall of the eye. The mechanical load onto the important region for central vision (optic nerve and macula) is not comparable between eyes with and without posterior staphyloma. Three-dimensional magnetic resonance imaging is a powerful tool to analyze the entire shape of the eye. When ultra-widefield optical coherence tomography is available, it is expected to be a new tool that will surpass 3-dimensional magnetic resonance imaging. In the future, preventive therapies targeting staphyloma and eye deformity are expected before vision-threatening complications develop and it is too late for patients.
Berk, Thomas A; Schlenker, Matthew B; Campos-Möller, Xavier; Pereira, Austin M; Ahmed, Iqbal Ike K
2018-03-06
Femtosecond laser-assisted cataract surgery (FLACS) has emerged as an alternative to manual cataract surgery (MCS) for corneal incision and capsulorhexis creation, as well as nuclear fragmentation. This study compares postoperative refractive and visual outcomes in eyes receiving MCS or FLACS. Single-center, comparative, retrospective cohort analysis. Consecutive eyes receiving FLACS and MCS from July 1, 2012, to July 31, 2015, at a single tertiary care center. Demographic data, ocular history, preoperative measurements and biometry, and postoperative surgical results were retrospectively obtained and statistically analyzed using a generalized linear mixed model adjusting for differences in baseline characteristics and within-patient correlation. A 2-tailed P value <0.05 was considered statistically significant throughout the study. Percentage of eyes achieving absolute error (AE) ≤0.5 diopters (D). Secondary outcomes included percentage of eyes with AE ≤0.25 D and ≤1.0 D, and percentage of distance-targeted eyes achieving uncorrected distance visual acuity (UDVA) of 20/20 or better, 20/25 or better, and 20/30 or better. A total of 883 eyes received MCS and 955 received FLACS among 1089 patients. Some 82.6% of FLACS eyes and 78.8% of MCS eyes had ≤0.5 D of AE at 3 weeks, representing an adjusted odds ratio (OR) of 1.28 (95% confidence interval [CI], 0.98-1.66) of FLACS relative to MCS being within target. Some 97.1% of FLACS and 97.2% of MCS eyes had ≤1.0 D of AE (OR, 0.96; 95% CI, 0.57-1.60) and 49.3% of FLACS and 46.3% of MCS eyes, ≤0.25 D of AE (OR, 1.13; 95% CI, 0.91-1.39). Factors predictive of a favorable refractive outcome included axial length between 22 and 24.8 mm, receiving a toric intraocular lens, less preoperative cylinder, and greater preoperative average keratometry. There was no significant difference in the percentage of patients targeted for distance who achieved UDVA of 20/20 or better (P = 0.30), 20/25 or better (P = 0.06), or 20/30 or better (P = 0.66) vision. Postoperatively, there was no statistically significant difference found between eyes undergoing FLACS and eyes undergoing MCS with respect to refractive and visual outcomes. Copyright © 2018 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Bailey, Kate M; Hempstead, Julie E; Tobias, Jeremy R; Borst, Luke B; Clode, Alison B; Posner, Lysa P
2013-06-01
To determine whether repeated exposure to clinically relevant concentrations of tricaine methanesulfonate (MS-222) would alter retinal function or induce histologically detectable retinal lesions in koi carp (Cyprinus carpio). Prospective, controlled, experimental study. 18 healthy koi carp. 2 fish were euthanized at the start of the study, and eyes were submitted for histologic evaluation as untreated controls. Anesthesia was induced in the remaining fish with 200 mg of MS-222/L and maintained with concentrations of 125 to 150 mg/L for a total exposure time of 20 minutes daily on 1 to 13 consecutive days. On days 1, 7, and 13, electroretinography of both eyes was performed in all fish remaining in the study, and 2 fish were euthanized immediately after each procedure for histologic evaluation of the eyes. Median b-wave amplitudes were compared among study days for right eyes and for left eyes via 1-way repeated-measures ANOVA with a Bonferroni correction for multiple comparisons. Median b-wave amplitudes on days 1, 7, and 13 were 17.7, 20.9, and 17.6 μV, respectively, for right eyes and 15.1, 16.9, and 14.3 μV, respectively, for left eyes. No significant differences in b-wave amplitudes were detected among study days. No histopathologic abnormalities were identified in the retinas of any fish treated with MS-222 or in control fish. Short-term exposure of koi carp to clinically relevant concentrations of MS-222 daily for up to 13 days was not associated with changes in retinal structure or function as measured in this study.
Draelos, Zoe Diana; Kononov, Tatiana; Fox, Theresa
2016-09-01
A 14-week single-center clinical usage study was conducted to test the efficacy of a peptide treatment serum and supporting skincare regimen in 29 women with mild to moderately photodamaged facial skin. The peptide treatment serum contained gamma-aminobutyric acid (GABA) and various peptides with neurotransmitter inhibiting and cell signaling properties. It was hypothesized that the peptide treatment serum would ameliorate eye and facial expression lines including crow's feet and forehead lines. The efficacy of the supporting skincare regimen was also evaluated. An expert investigator examined the subjects at rest and at maximum smile. Additionally, the subjects completed self-assessment questionnaires. At week 14, the expert investigator found a statistically significant improvement in facial lines, facial wrinkles, eye lines, and eye wrinkles at rest when compared to baseline results. The expert investigator also found statistically significant improvement at week 14 in facial lines, eye lines, and eye wrinkles when compared to baseline results at maximum smile. In addition, there was continued highly statistically significant improvement in smoothness, softness, firmness, radiance, luminosity, and overall appearance at rest when compared to baseline results at the 14-week time point. The test regimen was well perceived by the subjects for efficacy and product attributes. The products were well tolerated with no adverse events.
J Drugs Dermatol. 2016;15(9):1100-1106.
Quality indicators for eye bank.
Acharya, Manisha; Biswas, Saurabh; Das, Animesh; Mathur, Umang; Dave, Abhishek; Singh, Ashok; Dubey, Suneeta
2018-03-01
The aim of this study is to identify quality indicators of the eye bank and validate their effectivity. Adverse reaction rate, discard rate, protocol deviation rate, and compliance rate were defined as Quality Indicators of the eye bank. These were identified based on definition of quality that captures two dimensions - "result quality" and "process quality." The indicators were measured and tracked as part of quality assurance (QA) program of the eye bank. Regular audits were performed to validate alignment of standard operating procedures (SOP) with regulatory and surgeon acceptance standards and alignment of activities performed in the eye bank with the SOP. Prospective study of the indicators was performed by comparing their observed values over the period 2011-2016. Adverse reaction rate decreased more than 8-fold (from 0.61% to 0.07%), discard rate decreased and stabilized at 30%, protocol deviation rate decreased from 1.05% to 0.08%, and compliance rate reported by annual quality audits improved from 59% to 96% at the same time. In effect, adverse reaction rate, discard rate, and protocol deviation rate were leading indicators, and compliance rate was the trailing indicator. These indicators fulfill an important gap in available literature on QA in eye banking. There are two ways in which these findings can be meaningful. First, eye banks which are new to quality measurement can adopt these indicators. Second, eye banks which are already deeply engaged in quality improvement can test these indicators in their eye bank, thereby incorporating them widely and improving them over time.
Pax6 in Collembola: Adaptive Evolution of Eye Regression
Hou, Ya-Nan; Li, Sheng; Luan, Yun-Xia
2016-01-01
Unlike the compound eyes in insects, collembolan eyes are comparatively simple: some species have eyes with different numbers of ocelli (1 + 1 to 8 + 8), and some species have no apparent eye structures. Pax6 is a universal master control gene for eye morphogenesis. In this study, full-length Pax6 cDNAs, Fc-Pax6 and Cd-Pax6, were cloned from an eyeless collembolan (Folsomia candida, soil-dwelling) and an eyed one (Ceratophysella denticulata, surface-dwelling), respectively. Their phylogenetic positions are between the two Pax6 paralogs in insects, eyeless (ey) and twin of eyeless (toy), and their protein sequences are more similar to Ey than to Toy. Both Fc-Pax6 and Cd-Pax6 could induce ectopic eyes in Drosophila, while Fc-Pax6 exhibited much weaker transactivation ability than Cd-Pax6. The C-terminus of collembolan Pax6 is indispensable for its transactivation ability, and determines the differences of transactivation ability between Fc-Pax6 and Cd-Pax6. One of the possible reasons is that Fc-Pax6 accumulated more mutations at some key functional sites of C-terminus under a lower selection pressure on eye development due to the dark habitats of F. candida. The composite data provide a first molecular evidence for the monophyletic origin of collembolan eyes, and indicate the eye degeneration of collembolans is caused by adaptive evolution. PMID:26856893
Accommodative Performance of Children With Unilateral Amblyopia
Manh, Vivian; Chen, Angela M.; Tarczy-Hornoch, Kristina; Cotter, Susan A.; Candy, T. Rowan
2015-01-01
Purpose. The purpose of this study was to compare the accommodative performance of the amblyopic eye of children with unilateral amblyopia to that of their nonamblyopic eye, and also to that of children without amblyopia, during both monocular and binocular viewing. Methods. Modified Nott retinoscopy was used to measure accommodative performance of 38 subjects with unilateral amblyopia and 25 subjects with typical vision from 3 to 13 years of age during monocular and binocular viewing at target distances of 50, 33, and 25 cm. The relationship between accommodative demand and interocular difference (IOD) in accommodative error was assessed in each group. Results. The mean IOD in monocular accommodative error for amblyopic subjects across all three viewing distances was 0.49 diopters (D) (95% confidence interval [CI], ±1.12 D) in the 180° meridian and 0.54 D (95% CI, ±1.27 D) in the 90° meridian, with the amblyopic eye exhibiting greater accommodative errors on average. Interocular difference in monocular accommodative error increased significantly with increasing accommodative demand; 5%, 47%, and 58% of amblyopic subjects had monocular errors in the amblyopic eye that fell outside the upper 95% confidence limit for the better eye of control subjects at viewing distances of 50, 33, and 25 cm, respectively. Conclusions. When viewing monocularly, children with unilateral amblyopia had greater mean accommodative errors in their amblyopic eyes than in their nonamblyopic eyes, and when compared with control subjects. This could lead to unintended retinal image defocus during patching therapy for amblyopia. PMID:25626970
Fukuoka, Hideki; Nagaya, Masahiro; Toba, Kenji
2015-10-29
The current state of eye diseases and treatments in the elderly as well as the relationships between dementia and systemic diseases remain unclear. Therefore, this study evaluated the prevalence of eye diseases, visual impairment, cognitive impairment, and falls (which are an important health issue and are considered one of the Geriatric Giants) in super-elderly people in Japan. The subjects were 31 elderly people (62 eyes; mean age: 84.6 ± 8.8 years; age range 61-98 years) who were admitted to a geriatric health services facility. Eye treatment status, systemic diseases, dementia, and recent falls were investigated. Eye examinations including vision and intraocular pressure measurement, and slit-lamp biomicroscopy were conducted. Mean best corrected visual acuity (logMAR) was 0.51 ± 0.56, and mean intraocular pressure was 13.7 ± 3.5 mmHg. Approximately half of the subjects exhibited excavation of the optic nerve head including cataracts and glaucoma. Ten subjects had visual impairment (i.e., visual acuity of the eye with the better vision <20/40). The mean Hasegawa dementia scale scores between the visually impaired and non-visually impaired groups were 10.2 ± 6 and 16 ± 8 points, respectively (p < 0.05). Furthermore, 70% of subjects with visual impairment experienced a fall in the past year compared to 48% of those without visual impairment, although the difference was not significant. Regarding systemic diseases, there were 6, 5, and 15 cases of diabetes, hyperlipidemia, and hypertension, respectively. There was no significant difference between these systemic diseases and visual function after adjusted for age and gender. The percentages of patients with age-related eye diseases and poor visual acuity in a geriatric health services facility were extremely high. Compared to those without visual impairment, those with visual impairment had lower dementia scores and a higher rate of falls.
Corticosteroid implants for chronic non-infectious uveitis
Brady, Christopher J; Villanti, Andrea C; Law, Hua Andrew; Rahimy, Ehsan; Reddy, Rahul; Sieving, Pamela C; Garg, Sunir J; Tang, Johnny
2016-01-01
Background Uveitis is a term used to describe a heterogeneous group of intraocular inflammatory diseases of the anterior, intermediate, and posterior uveal tract (iris, ciliary body, choroid). Uveitis is the fifth most common cause of vision loss in high-income countries, accounting for 5% to 20% of legal blindness, with the highest incidence of disease in the working-age population. Corticosteroids are the mainstay of acute treatment for all anatomical subtypes of non-infectious uveitis and can be administered orally, topically with drops or ointments, by periocular (around the eye) or intravitreal (inside the eye) injection, or by surgical implantation. Objectives To determine the efficacy and safety of steroid implants in people with chronic non-infectious posterior uveitis, intermediate uveitis, and panuveitis. Search methods We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register) (Issue 10, 2015), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to November 2015), EMBASE (January 1980 to November 2015), PubMed (1948 to November 2015), Latin American and Caribbean Health Sciences Literature Database (LILACS) (1982 to November 2015), the metaRegister of Controlled Trials (mRCT) (www.controlledtrials.com) (last searched 15 April 2013), ClinicalTrials.gov (www.clinicaltrials.gov), and the World Health Organization (WHO) International Clinical Trials Registry Platform(ICTRP) (www.who.int/ictrp/search/en).We did not use any date or language restrictions in the electronic search for studies. We last searched the electronic databases on 6 November 2015. We also searched reference lists of included study reports, citation databases, and abstracts and clinical study presentations from professional meetings. Selection criteria We included randomized controlled trials comparing either fluocinolone acetonide (FA) or dexamethasone intravitreal implants with standard-of-care therapy with at least six months of follow-up after treatment. We included studies that enrolled participants of all ages who had chronic non-infectious posterior uveitis, intermediate uveitis, or panuveitis with vision that was better than hand-motion. Data collection and analysis Two review authors independently reviewed studies for inclusion. Two review authors independently extracted data and assessed the risk of bias for each study. Main results We included data from two studies (619 eyes of 401 participants) that compared FA implants with standard-of-care therapy. Both studies used similar standard-of-care therapy that included administration of prednisolone and, if needed, immunosuppressive agents. The studies included participants from Australia, France, Germany, Israel, Italy, Portugal, Saudi Arabia, Spain, Switzerland, Turkey, the United Kingdom, and the United States. We assessed both studies at high risk of performance and detection bias. Only one study reported our primary outcome, recurrence of uveitis at any point during the study through 24 months. The evidence, judged as moderate-quality, showed that a FA implant probably prevents recurrence of uveitis compared with standard-of-care therapy (risk ratio (RR) 0.29, 95% confidence interval (CI) 0.14 to 0.59; 132 eyes). Both studies reported safety outcomes, and moderate-quality evidence showed increased risks of needing cataract surgery (RR 2.98, 95% CI 2.33 to 3.79; 371 eyes) and surgery to lower intraocular pressure (RR 7.48, 95% CI 3.94 to 14.19; 599 eyes) in the implant group compared with standard-of-care therapy through two years of follow-up. No studies compared dexamethasone implants with standard-of-care therapy. Authors’ conclusions After considering both benefits and harms reported from two studies in which corticosteroids implants were compared with standard-of-care therapy, we are unable to conclude that the implants are superior to traditional systemic therapy for the treatment of noninfectious uveitis. These studies exhibited heterogeneity in design and outcomes that measured efficacy. Pooled findings regarding safety outcomes suggest increased risks of post-implant surgery for cataract and high intraocular pressure compared with standard-of-care therapy. PMID:26866343
Torky, Magda A; Al Zafiri, Yousif A; Khattab, Abeer M; Farag, Rania K; Awad, Eman A
2017-07-17
This is an interventional prospective clinical study which was conducted to evaluate the efficacy, safety, predictability, ocular aberrations, and flap thickness predictability of Visumax femtosecond laser (FSL) compared to Moria M2 microkeratome (MK) in mild to moderate myopia. This study included 60 eyes who were divided into two groups. Thirty eyes in group (I) in which the flap was created with Visumax FSL, while in group II (30 eyes) the Moria M2 MK was used. Keratometric, refractive, and aberrometric measurements were compared preoperatively and 3 months postoperatively. The intraoperative subtraction pachymetry (the SP 100 Handy pachymeter (Tomey, Nagoya, Japan) was used for preoperative pachymetry and flap thickness measurement. No significant difference was found between the two groups in regards to postoperative manifest sphere, spherical equivalent, astigmatism, safety indices nor ocular aberrations. Twenty six eyes (86.6%) in group I and 23 eyes in group II (76.6%) were within ±0.5D of the intended correction and 23 eyes (76.6%) in group I and 15 eyes in group II (50%) were within ±0.25D of the intended correction. In group I, the mean postoperative actual flap thickness was 100.12 ± 16.1 μm (81 to 122 μm), while in group II, it was 104.6 ± 20.1 μm (62 to 155 μm). The difference was statistically significant (p = 0.001). Both Visumax and Moria M2 MK are safe and effective in treating myopia with no statistically significant difference in induction of ocular aberrations but with potential advantage for Visumax regarding predictability. More accurate flap thickness is achieved with Visumax femtolasik. This study was retrospectively registered on 19/6/2017. Trial registration number NCT03193411 , clinicalTrials.gov .
Faramarzi, Amir; Moshirfar, Majid; Karimian, Farid; Delfazayebaher, Siamak; Kheiri, Bahareh
2017-12-01
To compare the refractive and higher-order aberrations (HOAs) outcomes after photorefractive keratectomy (PRK) in patients with significant astigmatism using aspheric versus wavefront-guided aspheric profiles. Ophthalmic Research Center and Department of Ophthalmology, Shahid Beheshti University of Medical Sciences, Negah Eye Hospital, Tehran, Iran. Prospective randomized case series. One eye of each patient with a refractive astigmatism more than 2.00 diopters (D) randomly received aspheric PRK. In the other eye, wavefront-guided and aspheric treatment was performed using a personalized treatment advanced algorithm. Visual acuity, refractive errors, and HOAs were compared between the 2 groups preoperatively and 12 months postoperatively. The study comprised 32 patients (64 eyes). The mean preoperative refractive astigmatism was -4.07 D ± 1.64 (SD) and -4.02 ± 1.55 D in the aspheric group and wavefront-guided aspheric group, respectively (P = .2). The mean postoperative astigmatism was -0.46 ± 0.37 D and -0.82 ± 0.53 D in the aspheric group and wavefront-guided aspheric group, respectively (P = .02). Postoperatively, the root mean square of total HOAs was significantly increased in both groups. However, compared with wavefront-guided aspheric PRK, aspheric PRK induced fewer HOAs (P = .003). In eyes with high astigmatism, post-PRK residual astigmatism was lower in the aspheric group than in the wavefront-guided aspheric group. The increase in HOAs was significantly higher in the wavefront-guided aspheric group than in the aspheric group. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Intraocular distribution of topically applied hydrophilic and lipophilic substances in rat eyes.
Abdul Nasir, Nurul Alimah; Agarwal, Puneet; Agarwal, Renu; Iezhitsa, Igor; Alyautdin, Renad; Nukolova, Natalia N; Chekhonin, Vladimir P; Mohd Ismail, Nafeeza
2016-10-01
Topical administration is the preferred route of drug delivery for ophthalmic ailments. However, poor permeation through ocular surface and significant systemic absorption, makes the topical drug delivery challenging. Furthermore, distribution of topically delivered drugs varies with their physicochemical properties and the type of formulation used. Hence, this study was done to understand the pattern of ocular drug distribution of topically applied hydrophilic and lipophilic substances in two different formulations. 5-Carboxyfluorescein and 1,1'-dioctadecyl-3,3,3',3'-tetramethylindocarbocyanine perchlorate were used as representative candidates for hydrophilic and lipophilic substances, respectively. They were formulated in solution and liposomes. Single drop of either formulation containing hydrophilic or lipophilic substance was instilled topically, unilaterally to rat eyes. Subsequently, rats were sacrificed at 10, 30 and 120 min post-instillation. Eyes were cryosectioned and examined under confocal microscope to determine the fluorescence intensity in ocular tissues. Corneal permeation of hydrophilic and lipophilic substances in both formulations peaked at 30 min post-instillation. Liposomal-lipophilic dye and non-liposomal-hydrophilic dye showed better corneal distribution. Fluorescence was absent in contralateral eyes of non-liposomal-hydrophilic dye-treated animals but was present in contralateral eyes of liposomal-hydrophilic dye-treated animals. Fluorescence in contralateral eyes of liposomal-lipophilic dye-treated animals was significantly higher compared to non-liposomal-lipophilic dye-treated animals. Topically applied liposomal formulation of lipophilic substance provides higher corneal concentration of drug with lesser systemic absorption compared to its solution. For hydrophilic substance, topical use of solution provides greater corneal concentration compared to liposomes which is more likely to be absorbed systemically.
Vemala, Roopa; Sivaprasad, Sobha; Barbur, John L
2017-05-01
To evaluate chromatic sensitivity in patients with age-related macular degeneration (AMD) characterized by drusen and reticular pseudodrusen. To investigate whether the severity of color vision loss can distinguish between various stages of AMD and hence be used as an index of progression toward advanced AMD. Chromatic sensitivity was measured by using the Color Assessment and Diagnosis (CAD) test in asymptomatic individuals with early and intermediate AMD and compared to normative data. All study participants had logMAR visual acuity of 0.3 or better. The CAD thresholds measured in eyes with and without reticular pseudodrusen were also compared and related to central macular thickness (CMT). Student's t-test P values < 0.05 were considered significant. All early- and intermediate-AMD eyes (n = 90) had chromatic sensitivity loss in either RG (red/green) or YB (yellow/blue), or both (P < 0.0001) as compared to age-matched normal subjects. The eyes exhibited a range of CAD thresholds affecting both color mechanisms, but YB color thresholds were in general higher than RG thresholds (P < 0.001). Intermediate-AMD patients exhibited large intersubject variability. In general, eyes with reticular pseudodrusen and eyes with CMT < 200 μm had significantly higher CAD thresholds. The anatomic integrity of cone photoreceptors remains relatively unaffected in early and intermediate stages of AMD. The processing of cone signals in the retina can, however, be heavily disrupted with subsequent loss of both YB and RG chromatic sensitivity. The greatest losses were observed in eyes with reticular pseudodrusen.
Domalpally, Amitha; Clemons, Traci E; Danis, Ronald P; Sadda, SriniVas R; Cukras, Catherine A; Toth, Cynthia A; Friberg, Thomas R; Chew, Emily Y
2017-04-01
To compare rates of peripheral retinal changes in Age-Related Eye Disease Study 2 (AREDS2) participants with at least intermediate age-related macular degeneration (AMD) with control subjects without intermediate age-related changes (large drusen). Cross-sectional evaluation of clinic-based patients enrolled in AREDS2 and a prospective study. Participants from prospective studies. The 200° pseudocolor and fundus autofluorescence (FAF) images were captured on the Optos 200 Tx Ultrawide-field device (Optos, Dunfermline, Scotland) by centering on the fovea and then steering superiorly and inferiorly. The montaged images were graded at a reading center with the images divided into 3 zones (zone 1 [posterior pole], zone 2 [midperiphery], and zone 3 [far periphery]) to document the presence of peripheral lesions. Peripheral retinal lesions: drusen, hypopigmentary/hyperpigmentary changes, reticular pseudodrusen, senile reticular pigmentary changes, cobblestone degeneration, and FAF abnormalities. A total of 484 (951 eyes) AREDS2 participants with AMD (cases) and 89 (163 eyes) controls without AMD had gradable color and FAF images. In zones 2 and 3, neovascularization and geographic atrophy (GA) were present, ranging from 0.4% to 6% in eyes of cases, respectively, and GA was present in 1% of eyes of controls. Drusen were detected in 97%, 78%, and 64% of eyes of cases and 48%, 21%, and 9% of eyes of controls in zones 2 and 3 superior and 3 inferior, respectively (P < 0.001 for all). Peripheral reticular pseudodrusen were seen in 15%. Senile reticular pigmentary change was the predominant peripheral change seen in 48% of cases and 16% of controls in zone 2 (P < 0.001). Nonreticular pigment changes were less frequent in the periphery than in the posterior pole (46% vs. 76%) and negligible in controls. Peripheral retinal changes are more prevalent in eyes with AMD than in control eyes. Drusen are seen in a majority of eyes with AMD in both the mid and far periphery, whereas pigment changes and features of advanced AMD are less frequent. Age-related macular degeneration may be more than a "macular" condition but one that involves the entire retina. Future longitudinal studies of peripheral changes in AMD and their impact on visual function may contribute to understanding AMD pathogenesis. Published by Elsevier Inc.
[Evaluation of eye patching after cataract surgery in topical anesthesia].
Mayer, S; Wirbelauer, C; Häberle, H; Altmeyer, M; Pham, D T
2005-01-01
Although postoperative eye patching is a common practice its background is not well known. Therefore the necessity of eye patching after cataract surgery in topical anesthesia from the medical point of view and the patients' subjective opinion was studied. In this prospective and randomized study 133 patients received after cataract surgery either no covering of the eye (group1), a transparent eye shield for four hours (group 2), an eye pad for four hours (group 3) or an eye pad until the next morning (group 4). Clinical findings were noted and local symptoms, such as pain, foreign body sensation, tearing and photophobia were documented on a visual analogue scale (0 - 10). Furthermore, a questionnaire concerning the subjective opinion was handed out to the patient. The clinical findings revealed no significant differences between the groups. The mean values for local pain were 0.94 +/- 1.56, for the foreign body sensation 1.41 +/- 2.02, for tearing 0.99 +/- 1.8 and for photophobia 1.05 +/- 1.99. Comparing the groups there was significantly more pain and foreign body sensation reported by the patients in group 3, who received eye patching for 4 hours. 91 % of the unpatched patients had no discomfort, whereas 53 % of the patients wearing an eye pad until the next morning considered it as unnecessary. After cataract surgery in topical anesthesia only mild symptoms were noted. There were no significant differences between the groups in the objective clinical findings and the subjective feeling. These results indicate that after cataract surgery eye patching could be unnecessary.
Comparison of ablation centration after bilateral sequential versus simultaneous LASIK.
Lin, Jane-Ming; Tsai, Yi-Yu
2005-01-01
To compare ablation centration after bilateral sequential and simultaneous myopic LASIK. A retrospective randomized case series was performed of 670 eyes of 335 consecutive patients who had undergone either bilateral sequential (group 1) or simultaneous (group 2) myopic LASIK between July 2000 and July 2001 at the China Medical University Hospital, Taichung, Taiwan. The ablation centrations of the first and second eyes in the two groups were compared 3 months postoperatively. Of 670 eyes, 274 eyes (137 patients) comprised the sequential group and 396 eyes (198 patients) comprised the simultaneous group. Three months post-operatively, 220 eyes of 110 patients (80%) in the sequential group and 236 eyes of 118 patients (60%) in the simultaneous group provided topographic data for centration analysis. For the first eyes, mean decentration was 0.39 +/- 0.26 mm in the sequential group and 0.41 +/- 0.19 mm in the simultaneous group (P = .30). For the second eyes, mean decentration was 0.28 +/- 0.23 mm in the sequential group and 0.30 +/- 0.21 mm in the simultaneous group (P = .36). Decentration in the second eyes significantly improved in both groups (group 1, P = .02; group 2, P < .01). The mean distance between the first and second eyes was 0.31 +/- 0.25 mm in the sequential group and 0.32 +/- 0.18 mm in the simultaneous group (P = .33). The difference of ablation center angles between the first and second eyes was 43.2 < or = 48.3 degrees in the sequential group and 45.1 +/- 50.8 degrees in the simultaneous group (P = .42). Simultaneous bilateral LASIK is comparable to sequential surgery in ablation centration.
Yelnik, A P; Tasseel Ponche, S; Andriantsifanetra, C; Provost, C; Calvalido, A; Rougier, P
2015-12-01
The Romberg test, with the subject standing and with eyes closed, gives diagnostic arguments for a proprioceptive disorder. Closing the eyes is also used in balance rehabilitation as a main way to stimulate neural plasticity with proprioceptive, vestibular and even cerebellar disorders. Nevertheless, standing and walking with eyes closed or with eyes open in the dark are certainly 2 different tasks. We aimed to compare walking with eyes open, closed and wearing black or white goggles in healthy subjects. A total of 50 healthy participants were randomly divided into 2 protocols and asked to walk on a 5-m pressure-sensitive mat, under 3 conditions: (1) eyes open (EO), eyes closed (EC) and eyes open with black goggles (BG) and (2) EO, EO with BG and with white goggles (WG). Gait was described by velocity (m·s(-1)), double support (% gait cycle), gait variability index (GVI/100) and exit from the mat (%). Analysis involved repeated measures Anova, Holm-Sidak's multiple comparisons test for parametric parameters (GVI) and Dunn's multiple comparisons test for non-parametric parameters. As compared with walking with EC, walking with BG produced lower median velocity, by 6% (EO 1.26; BG 1.01 vs EC 1.07 m·s(-1), P=0.0328), and lower mean GVI, by 8% (EO 91.8; BG 66.8 vs EC 72.24, P=0.009). Parameters did not differ between walking under the BG and WG conditions. The goggle task increases the difficulty in walking with visual deprivation compared to the Romberg task, so the goggle task can be proposed to gradually increase the difficulty in walking with visual deprivation (from eyes closed to eyes open in black goggles). Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Rolando, Maurizio; Autori, Silvia; Badino, Francesco; Barabino, Stefano
2009-06-01
The aim of this study was to evaluate the efficacy of a non-Newtonian tear substitute containing 0.4% polyethylene glycol 400 (PEG 400) and 0.3% propylene glycol in an 0.18% hydroxypropyl-guar (HPG) containing vehicle (Systane Lubricant Eye Drops; Alcon) in reducing the signs and symptoms of dry eye, as well as its effect on ocular protection. Twenty patients with moderate to severe dry eye were enrolled in a 28-day prospective, randomized, controlled study. Subjects self-administered the HPG containing ocular lubricant four times daily (QID) over the study duration. After 28 days, the effect of the HPG containing ocular lubricant was evaluated by means of the Global Staining Score (a measure of the corneal and conjunctival staining), inter-blink tear film stability, Ocular Protection Index (OPI), and subjective symptoms. The HPG containing ocular lubricant produced statistically significant improvements compared with baseline in dry eye symptoms (P < 0.0001 at Days 7, 14, and 28); in ocular surface staining, as measured by a reduction in the Global Staining Score (P < 0.0001 at Days 7, 14, and 28); and in the OPI (P = 0.0025 at Day 14 and P = 0.0067 at Day 28). The improvements in ocular surface staining and dry eye symptoms with the HPG containing ocular lubricant -- evident as early as the first follow-up visit (Day 7) and continued throughout the 28 days of the study with a concurrent, increase in OPI to a level greater than unity -- indicate that this preparation is a fast-acting, long-lasting, and effective treatment for dry eye. In concurrence with the results from previously published clinical studies, the HPG containing ocular lubricant has shown efficacy in alleviating the signs and symptoms of dry eye as well as affording improved ocular surface protection.
Spatial and spectral analysis of corneal epithelium injury using hyperspectral images
NASA Astrophysics Data System (ADS)
Md Noor, Siti Salwa; Michael, Kaleena; Marshall, Stephen; Ren, Jinchang
2017-12-01
Eye assessment is essential in preventing blindness. Currently, the existing methods to assess corneal epithelium injury are complex and require expert knowledge. Hence, we have introduced a non-invasive technique using hyperspectral imaging (HSI) and an image analysis algorithm of corneal epithelium injury. Three groups of images were compared and analyzed, namely healthy eyes, injured eyes, and injured eyes with stain. Dimensionality reduction using principal component analysis (PCA) was applied to reduce massive data and redundancies. The first 10 principal components (PCs) were selected for further processing. The mean vector of 10 PCs with 45 pairs of all combinations was computed and sent to two classifiers. A quadratic Bayes normal classifier (QDC) and a support vector classifier (SVC) were used in this study to discriminate the eleven eyes into three groups. As a result, the combined classifier of QDC and SVC showed optimal performance with 2D PCA features (2DPCA-QDSVC) and was utilized to classify normal and abnormal tissues, using color image segmentation. The result was compared with human segmentation. The outcome showed that the proposed algorithm produced extremely promising results to assist the clinician in quantifying a cornea injury.
Estimation of stereovision in conditions of blurring simulation
NASA Astrophysics Data System (ADS)
Krumina, Gunta; Ozolinsh, Maris; Lacis, Ivazs; Lyakhovetskii, Vsevolod
2005-08-01
The aim of this study was to evaluate the simulation of eye pathologies, such as amblyopia and cataracts, to estimate the stereovision in artificial conditions, and to compare the results on the stereothreshold obtained in artificial and real- pathologic conditions. Characteristic of the above-mentioned real-life forms of a reduced vision is a blurred image in one of the eyes. The blurring was simulated by (i) defocusing, (ii) blurred stimuli on the screen, and (iii) occluding of an eye with PLZT or PDLC plates. When comparing the methods, two parameters were used: the subject's visual acuity and the modulation depth of the image. The eye occluder method appeared to systematically provide higher stereothreshold values than the rest of the methods. The PLZT and PDLC plates scattered more in the blue and decreased the contrast of the stimuli when the blurring degree was increased. In the eye occluder method, the stereothreshold increased faster than in the defocusation and monitor stimuli methods when the visual acuity difference was higher than 0.4. It has been shown that the PLZT and PDLC plates are good optical phantoms for the simulation of a cataract, while the defocusation and monitor stimuli methods are more suitable for amblyopia.
Comparison of the Ahmed glaucoma valve with the Baerveldt glaucoma implant: a meta-analysis.
Wang, Yi-Wen; Wang, Ping-Bao; Zeng, Chao; Xia, Xiao-Bo
2015-10-13
This study aims to compare the efficacy and safety of the Ahmed glaucoma valve (AGV) with the Baerveldt glaucoma implant (BGI) in glaucoma patients. Databases were searched to identify studies that met pre-stated inclusion criteria, involving randomized controlled clinical trials (RCTs) and non-randomized controlled clinical trials. Treatment effect was analyzed using a random-effect model. Ten controlled clinical trials (1048 eyes) were analyzed, involving two RCTs and eight retrospective comparative studies. Short-term results (6-18 months) and long-term results (>18 months) were analyzed separately. There was no significant difference in the success rate for short-term follow-up between the AGV and BGI groups (5 studies, 714 eyes, odds ratio [OR]: 0.97; 95 % confidence interval [CI]: 0.56, 1.66; P = 0.90). For long-term pooled results (7 studies, 835 eyes), the success rate of AGVs was lower than that of BGIs (OR: 0.73; 95 % CI: 0.54, 0.99, P = 0.04), However, subgroup and sensitivity analyses did not show a significant difference in the success rate between the two groups (P ≥0.05). The AGV group had a higher mean intraocular pressure than the BGI group in short-term (6 studies, 685 eyes, weighted mean difference [WMD]: 2.12 mmHg; 95 % CI: 0.72-3.52; P <0.05) and long-term pooled results (7 studies, 659 eyes, WMD: 1.85 mmHg; 95 % CI: 0.43, 3.28; P = 0.01). The BGI group required fewer glaucoma medications after implantation than the AGV group in two follow-up periods (all P <0.05). The AGV was found to be associated with a significantly lower frequency of total complications (8 studies, 971 eyes, OR: 0.67; 95 % CI: 0.50-0.90; P = 0.007) and severe complications (8 studies, 971 eyes, OR: 0.57; 95 % CI: 0.36-0.91; P = 0.02) than the BGI. The study showed no significant difference in success rate between the two groups. The BGI was more effective for control of intraocular pressure and required fewer medications than the AGV, but the AGV had lower incidence of total and severe complications than the BGI.
Roca, Jose A; Wu, Lihteh; Fromow-Guerra, Jans; Rodríguez, Francisco J; Berrocal, Maria H; Rojas, Sergio; Lima, Luiz H; Gallego-Pinazo, Roberto; Chhablani, Jay; Arevalo, J Fernando; Lozano-Rechy, David; Serrano, Martin
2018-02-08
To compare the functional and anatomical outcomes of eyes with chronic central serous chorioretinopathy treated with yellow micropulse (MP) laser versus half-dose verteporfin photodynamic therapy (PDT). This is a multicentre, retrospective comparative study of 92 eyes treated with yellow MP laser (duty cycle of 5%, zero spacing between spots, spot size varied from 100 to 200 µm, power varied from 320 to 660 mW, and the pulse burst duration was 200 ms) and 67 eyes treated with PDT (half-dose verteporfin (3 mg/m 2 ) infused over 10 min), followed by laser activation for 83 s. Spot sizes varied from 400 to 2000 µm. In the MP group, at 12 months of follow-up, the mean best corrected visual acuity (BCVA) improved from the logarithm of the minimum angle of resolution (logMAR) of 0.41±0.27 at baseline to 0.21±0.26 (P<0.0001), 48.9% (45/92) of eyes had an improvement of ≥3 lines of BCVA from baseline, 48.9% (45/92) of eyes remained within 2 lines of baseline BCVA, and only 2.2% (2/92) of eyes lost ≥3 lines of BCVA from baseline. In the PDT group, at 12 months of follow-up, the mean BCVA changed from logMAR of 0.50±0.34 at baseline to 0.47±0.34 (P=0.89), 19% (13/67) of eyes had an improvement of ≥3 lines of BCVA from baseline, 73% (49/67) of eyes remained within 2 lines of baseline BCVA, and 7% (5/67) of eyes lost ≥3 lines of BCVA from baseline. There were no adverse events attributable to the yellow MP laser treatment. One eye in the PDT group developed choroidal neovascularisation, which was treated with three intravitreal bevacizumab injections. Both PDT and MP are effective in restoring the macular anatomy. In places where PDT is not available, yellow MP laser may be an adequate treatment alternative. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Cohen, Elisabeth J.
2009-01-01
Purpose: To test the hypothesis that keratoconus and pellucid patients who have glaucoma or are suspected of having glaucoma have lower corneal hysteresis (CH) and/or corneal resistance factor (CRF) measurements compared to controls. Methods: A prospective study at a tertiary eye center of keratoconus and pellucid patients with glaucoma or suspected of having glaucoma, and age-matched keratoconus and pellucid controls, was performed. After informed consent was obtained, corneal topography, ocular response analyzer measurements, pachymetry, intraocular pressure, A-scan measurements, Humphrey visual fields (VFs), and disc photos were done. Analyses compared cases to controls on primary (CH and CRF) and secondary variables. Disc photos and VFs were rated in a masked fashion. Results: The mean CH (8.2, SD=1.6, vs 8.3, SD=1.5) and CRF (7.3, SD=2.0, vs 6.9, SD=2.1) were low and did not differ significantly between 20 study patients (29 eyes) and 40 control patients (61 eyes), respectively. CH had a negative, significant correlation with maximum corneal curvature by topography (P < .002) and positive, significant correlation with central corneal thickness (P < .003). The mean cup-disc ratio was larger among cases than controls (0.54, SD=0.20, vs 0.38, SD=0.20; P = .003). VFs were suggestive of glaucoma more often among the study eyes than controls (11 of 29, 37.9%, vs 8 of 60, 13.3%; P =.019). Conclusions: CH was low in study and control patients and was correlated with severity of keratoconus/pellucid, but not with glaucoma/suspected glaucoma or control status. Evidence of glaucoma was more common in study eyes than controls, but was present in both. PMID:20126503
Jacobi, Christina; Kruse, Friedrich E; Cursiefen, Claus
2012-12-01
The aim of this prospective, randomized, clinical, single-center study was to compare the safety and efficacy of 2 ocular surface lubricant eye drops: preservative-free hydroxypropyl (HP)-Guar (SYSTANE UD(®)) eye drops versus preservative-free Tamarindus indica seed polysaccharide (TSP) 1% (VISINE INTENSIV 1% EDO(®)) eye drops. Fifty-six eyes of 28 patients with moderate keratoconjunctivitis sicca (DEWS severity level 2) were enrolled in the trial. Patients were randomized for 2 treatment groups (SYSTANE UD eye drops vs. VISINE INTENSIV 1% EDO eye drops). The eye drops in both groups were applied 5 times per day for 3 months. Statistical analyses were performed using Statistica™ software (Mann-Whitney U-test and Wilcoxon test). P-Values<0.05 were considered significant. After 3 months of treatment the patients of both groups had subjective benefit in the relief of symptoms of dry eye disease evaluated by the Ocular Surface Disease Index (OSDI) questionnaire score. Patients treated with HP-Guar and TSP showed improvements in tear film stability measured by tear break-up time (TBUT), which are statistically significant in the HP-Guar group (P=0.02). The results of this clinical trial show improvements of symptoms and signs in patients with moderate dry eye after the consistent use of preservative-free HP-Guar and TSP lubricant eye drops. Both artificial tear formulations produce amelioration in tear film stability improving eye conditions and patient quality of life. HP-Guar seems to be slightly more effective in improving ocular surface protection by decreasing tear film evaporation.
Efficacy of pressure topical anaesthesia in punctal occlusion by diathermy
Law, R W K; Li, R T H; Lam, D S C; Lai, J S M
2005-01-01
Aims: To prospectively compare the efficacy and safety of pressure topical anaesthesia in punctal occlusion by using cautery in the treatment of dry eye syndrome (DES) with that of conventional treatment by using needle injection of anaesthetic agents. Methods: In a randomised controlled trial, 18 consecutive adult patients with DES requiring punctal occlusion were recruited over a 10 month period. Consenting patients were randomised into two groups. Group A patients received pressure topical anaesthesia in the right eye followed by injection anaesthesia in the left eye. Group B was vice versa. Punctal occlusion using cautery was performed in each eye after a specified time following the application of anaesthesia. The main outcome measures were the pain experienced during application of anaesthesia and that during punctal occlusion. Results: 36 eyes of 18 patients were randomised to receive injection anaesthesia in one eye and pressure topical anaesthesia in the other. Nine patients (nine females) were in group A and nine patients (seven females, two males) in group B. The mean age of group A patients was 45.3 (SD 13.5) years, and that of group B patients was 55.6 (12.6) years. The two groups were comparable in terms of mean age (p = 0.117) and mean pain score for pressure topical anaesthesia application (p = 0.612), injection anaesthesia application (p = 0.454), diathermy in pressure anaesthetised eyes (p = 0.113), and diathermy in injection anaesthetised eyes (p = 0.289). Paired t test was used to compare the mean pain score for pressure topical anaesthesia application (16.8 (24.8)) with those for injection anaesthesia application (56.7 (30.0)). 18 eyes of 18 patients were compared with the fellow eye of the same 18 patients. The mean pain score for injection anaesthesia was greater than for pressure topical anaesthesia application (p<0.0001) (statistical power = 0.87). No statistically significant difference was found in the mean pain score for diathermy for eyes that received pressure topical anaesthesia (20.5 (27.5)) compared with eyes that received injection anaesthesia (23.1 (26.3)) (p = 0.760) (statistical power = 0.96). All 18 patients preferred pressure topical anaesthesia to injection anaesthesia. Conclusion: Injection anaesthesia for punctal occlusion is more painful than pressure topical anaesthesia application. However, the pain experienced during diathermy application for punctal occlusion is similar between pressure anaesthetised eyes and injection anaesthetised eyes. Pressure topical anaesthesia is a less painful (in terms of anaesthesia application) but equally effective alternative to conventional injection anaesthesia when used for punctal occlusion. PMID:16234451
Efficacy of pressure topical anaesthesia in punctal occlusion by diathermy.
Law, R W K; Li, R T H; Lam, D S C; Lai, J S M
2005-11-01
To prospectively compare the efficacy and safety of pressure topical anaesthesia in punctal occlusion by using cautery in the treatment of dry eye syndrome (DES) with that of conventional treatment by using needle injection of anaesthetic agents. In a randomised controlled trial, 18 consecutive adult patients with DES requiring punctal occlusion were recruited over a 10 month period. Consenting patients were randomised into two groups. Group A patients received pressure topical anaesthesia in the right eye followed by injection anaesthesia in the left eye. Group B was vice versa. Punctal occlusion using cautery was performed in each eye after a specified time following the application of anaesthesia. The main outcome measures were the pain experienced during application of anaesthesia and that during punctal occlusion. 36 eyes of 18 patients were randomised to receive injection anaesthesia in one eye and pressure topical anaesthesia in the other. Nine patients (nine females) were in group A and nine patients (seven females, two males) in group B. The mean age of group A patients was 45.3 (SD 13.5) years, and that of group B patients was 55.6 (12.6) years. The two groups were comparable in terms of mean age (p=0.117) and mean pain score for pressure topical anaesthesia application (p=0.612), injection anaesthesia application (p=0.454), diathermy in pressure anaesthetised eyes (p=0.113), and diathermy in injection anaesthetised eyes (p=0.289). Paired t test was used to compare the mean pain score for pressure topical anaesthesia application (16.8 (24.8)) with those for injection anaesthesia application (56.7 (30.0)). 18 eyes of 18 patients were compared with the fellow eye of the same 18 patients. The mean pain score for injection anaesthesia was greater than for pressure topical anaesthesia application (p<0.0001) (statistical power=0.87). No statistically significant difference was found in the mean pain score for diathermy for eyes that received pressure topical anaesthesia (20.5 (27.5)) compared with eyes that received injection anaesthesia (23.1 (26.3)) (p=0.760) (statistical power=0.96). All 18 patients preferred pressure topical anaesthesia to injection anaesthesia. Injection anaesthesia for punctal occlusion is more painful than pressure topical anaesthesia application. However, the pain experienced during diathermy application for punctal occlusion is similar between pressure anaesthetised eyes and injection anaesthetised eyes. Pressure topical anaesthesia is a less painful (in terms of anaesthesia application) but equally effective alternative to conventional injection anaesthesia when used for punctal occlusion.
Studies of the vestibulo-ocular reflex on STS 4, 5 and 6
NASA Technical Reports Server (NTRS)
Thornton, William E.; Pool, Sam L.; Moore, Thomas P.; Uri, John J.
1988-01-01
The vestibulo-ocular reflex (VOR) may be altered by weightlessness. Since this reflex plays a large role in visual stabilization, it was important to document any changes caused by space flight. This is a report on findings on STS-4 through 6 and is part of a larger study of neurosensory adaptation done on STS-4 through 8. Voluntary horizontal head oscillations at 1/3 Hz with amplitude of 30 deg right and left of center were recorded by a potentiometer and compared to eye position recorded by electroculography under the following conditions: eyes open, head fixed, tracking horizontal targets switched 0, 15, and 30 degrees right and left (optokinetic reflex - OKR - and calibration); eyes open and fixed on static external target with oscillation, (vestibulo ocular reflex, eyes closed - VOR EC); eyes open and wearing opaque goggles with target fixed in imagination (vestibulo-ocular reflex, eyes shaded - VOR ES); and eyes open and fixed on a head synchronized target with head oscillation (VOR suppression). No significant changes were found in voluntary head oscillation frequency or amplitude in those with (n=5), and without (n=3), space motion sickness (SMS), with phase of flight or test condition. Variations in head oscillation were too small to have produced detectable changes in test results.
Lim, Michele C; Tanimoto, Suzana A; Furlani, Bruno A; Lum, Brent; Pinto, Luciano M; Eliason, David; Prata, Tiago S; Brandt, James D; Morse, Lawrence S; Park, Susanna S; Melo, Luiz A S
2009-07-01
To determine if panretinal photocoagulation (PRP) alters retinal nerve fiber layer (RNFL) thickness and optic nerve appearance. Patients with diabetes who did and did not undergo PRP and nondiabetic control subjects were enrolled in a prospective study. Participants underwent optical coherence tomography of the peripapillary retina and optic nerve. Stereoscopic optic nerve photographs were graded in a masked fashion. Ninety-four eyes of 48 healthy individuals, 89 eyes of 55 diabetic patients who did not undergo PRP, and 37 eyes of 24 subjects with diabetes who underwent PRP were included in this study. Eyes that had been treated with PRP had thinner peripapillary RNFL compared with the other groups; this was statistically significantly different in the inferior (P = .004) and nasal (P = .003) regions. Optic nerve cupping did not increase with severity of disease classification, but the proportion of optic nerves graded as suspicious for glaucoma or as having nonglaucomatous optic neuropathy did (P = .008). These grading categories were associated with thinner RNFL measurements. Diabetic eyes that have been treated with PRP have thinner RNFL than nondiabetic eyes. Optic nerves in eyes treated with PRP are more likely to be graded as abnormal, but their appearance is not necessarily glaucomatous and may be related to thinning of the RNFL.
How young adults with autism spectrum disorder watch and interpret pragmatically complex scenes.
Lönnqvist, Linda; Loukusa, Soile; Hurtig, Tuula; Mäkinen, Leena; Siipo, Antti; Väyrynen, Eero; Palo, Pertti; Laukka, Seppo; Mämmelä, Laura; Mattila, Marja-Leena; Ebeling, Hanna
2017-11-01
The aim of the current study was to investigate subtle characteristics of social perception and interpretation in high-functioning individuals with autism spectrum disorders (ASDs), and to study the relation between watching and interpreting. As a novelty, we used an approach that combined moment-by-moment eye tracking and verbal assessment. Sixteen young adults with ASD and 16 neurotypical control participants watched a video depicting a complex communication situation while their eye movements were tracked. The participants also completed a verbal task with questions related to the pragmatic content of the video. We compared verbal task scores and eye movements between groups, and assessed correlations between task performance and eye movements. Individuals with ASD had more difficulty than the controls in interpreting the video, and during two short moments there were significant group differences in eye movements. Additionally, we found significant correlations between verbal task scores and moment-level eye movement in the ASD group, but not among the controls. We concluded that participants with ASD had slight difficulties in understanding the pragmatic content of the video stimulus and attending to social cues, and that the connection between pragmatic understanding and eye movements was more pronounced for participants with ASD than for neurotypical participants.
Ozyol, Erhan; Ozyol, Pelin; Doğanay Erdoğan, Beyza; Onen, Mehmet
2014-01-01
This study evaluated anterior hyaloid damage (AHD), AHD-related Nd:YAG laser parameters, and retinal complications in subjects that underwent Nd:YAG laser posterior capsulotomy for cataracts. In this prospective, cross-sectional study, 277 pseudophakic eyes of 216 patients treated with Nd:YAG laser capsulotomy for posterior capsule opacification were enrolled. Pulse number, pulse energy, and total energy were noted for each eye. All procedures were performed with a sense of anterior hyaloid protection. Anterior hyaloid faces were assessed during procedure and 1 day after the procedure. Eyes with biomicroscopically invisible anterior hyaloid face were excluded from statistical analysis. Eyes with and without AHD were compared according to Nd:YAG laser parameters. Retinal complications were evaluated at day 1, week 1, month 1, and month 3. In 22 eyes (7.9 % of 277 eyes), the anterior hyaloid face couldn't be assessed biomicroscopically. Anterior hyaloid damage was observed in 49 eyes (19.2 % of 255 eyes). The pulse number, pulse energy, and total energy were observed to be higher in eyes with AHD (P < .001, P = .024, P < .001, respectively). Cystoid macular edema was detected in five eyes (three with AHD) at 1-week examination. Localized retinal detachment occurred in one eye with AHD. Occurrence of retinal complication in the AHD(+) group was 12.7 times higher than in the AHD(-) group, adjusted for total energy used (P < 0.001). The risk of AHD may increase with high pulse number, pulse energy, and total energy. Anterior hyaloid face integrity should be considered for YAG laser-related retinal complications.
Bar-Sela, Shai M; Har-Noy, Nurit Birman; Spierer, Abraham
2014-08-01
To evaluate the risk factors for secondary membrane (SM) formation after congenital cataract surgery with intraocular lens (IOL) implantation. A retrospective non-interventional comparative study. Thirty-nine patients (63 eyes) aged 1-135 months. The study included patients who underwent cataract extraction and primary IOL implantation between 1994 and 2001 at the University Hospital. The postoperative follow-up was 6-24 months. Thirty-three eyes received a poly(methyl methacrylate) (PMMA) IOL without square edges, 29 eyes received a hydrophobic acrylic IOL with truncated square edges (AcrySof), and there was no data for IOL type in one eye. Thirty-nine eyes had primary posterior capsulotomy (PPC) and anterior vitrectomy (AV) and in 24 eyes the posterior capsule was left intact. Cox proportional hazard regression analysis was performed to identify significant risk factors for SM formation, and Wilcoxon test to evaluate the difference in time from surgery to SM formation. SM developed in 24 eyes (38 %)--58 % of eyes with an intact posterior capsule and 26 % of eyes having PPC and AV, 42 % of eyes with a PMMA IOL, and 34 % of eyes with an AcrySof lens. In multivariate Cox regression analysis intraoperative PPC and AV (P = 0.02) and AcrySof lens implantation (P = 0.097) were associated with decreased postoperative incidence of SM formation. Median time until SM development was 2.9 months with PMMA IOLs (range 1-17 months) and 6 months with AcrySof lenses (range 1-21.8 months) (P = 0.037). Posterior capsule management as well as IOL design and material influence the incidence and the timing of SM formation after primary IOL implantation in children.
Holz, Eric R.
2009-01-01
Purpose: To study the refractive outcomes of 3-port lens-sparing vitrectomy (LSV) for subtotal retinal detachments due to retinopathy of prematurity (ROP). Lens-sparing vitrectomy may provide superior refractive outcomes by limiting induced myopia of prematurity. Methods: This is a retrospective, consecutive, nonrandomized, comparative (paired eye) study. Entrance criteria were previous complete ablative laser for threshold ROP in both eyes, followed by LSV in one eye for stage 4A traction retinal detachment. Both eyes then maintained complete retinal attachment. Main outcome variables were cycloplegic refraction, keratometry, and biometric values for axial length, lens thickness, and anterior chamber depth. Results: Nine patients met inclusion criteria. Lens-sparing vitrectomy eyes were significantly less myopic than control eyes (−6.78 D vs −10.33 D, P < .005). The reduction in myopia in LSV eyes was predominantly due to increased anterior chamber depth (3.81 mm ± 0.217 vs 2.96 mm ± 0.232, P < .005). There was a minor contribution from reduced corneal power in LSV eyes (43.89 D ± 0.253 vs 44.20 D ± 0.265, P < .005). There was a minor negative impact from increased lens thickness in LSV eyes (3.85 ± 0.32 mm vs 3.74 ± 0.31, P < .005). There was no significant difference in axial length or lens power between the LSV and control groups. Conclusions: The data demonstrate that infant eyes undergoing 3-port LSV for stage 4A ROP develop less myopia than fellow eyes treated with laser alone. The difference is due to posterior displacement of the lens-iris diaphragm with a smaller contribution from reduced corneal power. The reduction in myopia may improve functional outcomes following 3-port LSV for stage 4A ROP. PMID:20126504
Phasukkijwatana, Nopasak; Lertrit, Patcharee; Liammongkolkul, Sompong; Prabhasawat, Pinnita
2011-09-01
To compare the concentrations of epitheliotrophic factors in autologous serum eye drops (ASE) prepared from sera of chronic Stevens-Johnson syndrome (SJS) patients with dry eyes to those prepared from non-autoimmune dry eye controls and to study the stability of the epitheliotrophic factors in different storage conditions. Twenty-percent ASE were prepared from 10 chronic SJS patients with dry eyes and 10 age-matched non-autoimmune dry eye controls. The concentrations of major epitheliotrophic factors comprising epidermal growth factor (EGF), transforming growth factor-beta1 (TGF-β1), transforming growth factor-beta2 (TGF-β2), and fibronectin in those ASE preparations were determined by enzyme-linked immunosorbent assay (ELISA) at baseline and after different storage conditions: at 4 °C for 1 week and 1 month; and at -20 °C for 1, 3 and 6 months. There were no significant differences in the concentrations of EGF, TGF-β1, TGF-β2 and fibronectin in 20% ASE between the SJS and control groups (EGF: 176.9 ± 40.9 vs. 185.5 ± 36.9 pg/mL, TGF-β1: 9.5 ± 2.1 vs. 9.5 ± 1.9 ng/mL, TGF-β2: 55.3 ± 30.0 vs. 63.91 ± 45.6 pg/mL and fibronectin: 70.5 ± 20.2 vs. 62.2 ± 21.3 µg/mL, respectively). These factors were stable at 4 °C for up to 1 month. Storage at -20 °C for up to 6 months resulted in a slight decrease in TGF-β1 (SJS: from 9.5-8.4 ng/mL, p < 0.01 and control: from 9.5-8.1 ng/mL, p < 0.01). The results suggested that the epitheliotrophic capacity of ASE from chronic SJS should be comparable to those from non-autoimmune dry eye patients, and that ASE should be sufficiently stable for up to 6 months, if stored properly at -20 °C.
Using InterWave Aberrometry to Measure and Improve the Quality of Vision in LASIK Surgery
Thompson, Keith P.; Staver, P. Randall; Garcia, Jose R.; Burns, Stephen A.; Webb, Robert H.; Stulting, R. Doyle
2005-01-01
Objective To compare visual outcomes in eyes undergoing aberrometry-guided (InterWave) LASIK with those in eyes undergoing standard LASIK treatment based upon refractive measures. Design Single-center, comparative, interventional, consecutive case series. Participants Four hundred two consecutive eyes undergoing LASIK were analyzed retrospectively. One group, 106 eyes undergoing primary LASIK and 224 eyes undergoing LASIK enhancement, was treated with standard LASIK treatment using a 5.5-mm optical zone, 1.5-mm transition zone laser with the settings determined by manifest refraction. The second group, 44 untreated (primary) eyes and 28 previously treated (enhancement) eyes, received a multipass, multistage treatment in which the laser settings for each stage were determined by aberrometry measurements. Eyes with desired monovision (undercorrected) outcome and preoperative hyperopia were excluded from the study. Intervention An aberrometry-guided laser treatment (InterWave LASIK) was compared with the standard LASIK treatment based upon the manifest refraction. Main Outcome Measures Uncorrected visual acuity (VA), manifest refraction, best spectacle-corrected VA (BSCVA), severity of halos, and root mean square (RMS) retinal blur area measured at 3 months postoperatively. Results Three months postoperatively there was no difference in uncorrected VA, BSCVA, refraction, or RMS retinal blur areas for pupil sizes of 3.5 mm between eyes treated by InterWave and those treated by standard LASIK. However, InterWave LASIK reduced the retinal blur area by 48% (P<0.0103) and 58% (P<0.0004) in primary cases and 43% (P<0.0430) and 74% (P<0.0271) in enhancement cases, respectively, for pupil sizes of 4.5 and 6.5 mm relative to standard LASIK treatments. Patients undergoing InterWave-guided treatment reported less severity of halo (0.37 vs. 0.98 [P<0.016] for primary cases and 0.35 vs. 0.73 [P<0.04] for enhancement cases). Conclusion InterWave LASIK achieved acuity and refractive results equivalent to those of standard LASIK treatment based upon refraction, but resulted in superior quality mesopic vision. PMID:15234139
New screening methods for donor eye-bank eyes.
Terry, M A; Ousley, P J
1999-07-01
Current methods of screening donor eyes for corneal transplantation are not always effective in excluding corneas with abnormal topography. We used the Orbscan to determine whether corneal-thickness maps could be used as a technique for donor tissue screening. Forty eye-bank eyes were measured with the Orbscan, and a corneal-thickness map was generated. Average central pachymetry measurements from each map were compared with the thinnest midperipheral thickness reading. Two eyes from a donor who had photorefractive keratectomy (PRK) and two eyes from a donor with keratoconus were then compared with the normal donor eye results. The average difference between the thinnest midperipheral pachymetry and the central pachymetry in the control group was 0.040 +/- 0.026 mm. The eyes from the donor with PRK showed larger disparities between the central and midperipheral thicknesses because of the thinned central cornea, with differences of 0.154 mm in the right eye and 0.106 mm in the left eye. The eyes from the donor with keratoconus had midperipheral corneas that were thinner than the center, indicating eccentric, ectatic cones. The differences in thickness between the center and midperiphery in the eyes from the donor with PRK and the donor with keratoconus differed from the control group by >2 SD. Diseases or surgery that affect the relationship between the central and midperipheral corneal thickness may be screened through Orbscan pachymetry mapping with comparison with a normal range.
Painless needle insertion in regional anesthesia of the eye.
Vaalamo, M O; Paloheimo, M P; Nikki, P H
1995-04-01
We examined a new technique of applying topical anesthetic with cotton tip sticks to the conjunctiva before needle insertion in regional anesthesia of the eye. Oxybuprocaine 0.4% and lidocaine 4% were compared with balanced salt solution (BSS) as topical anesthetics of the conjunctiva in Study 1. Ninety patients were randomly assigned into three groups (n = 30) to receive one of the three topical anesthetics in a double-blind manner. Pain of the needle insertions was measured with visual analog scale score (VAS) and quantitative surface electromography (qEMG). Both oxybuprocaine and lidocaine reduced pain significantly when compared to BSS. In Study 2, with healthy volunteers, we compared our previous practice of merely applying three consecutive drops of oxybuprocaine on the conjunctiva before needle insertions to the new technique of placing additional cotton tip sticks soaked in oxybuprocaine on the conjunctiva. We found the needle insertion virtually pain free when the cotton tip sticks were added to the topical anesthesia. The use of this simple method of topical anesthesia before the eye block increases patient comfort significantly.
Assessment of eye lens doses for workers during interventional radiology procedures.
Urboniene, A; Sadzeviciene, E; Ziliukas, J
2015-07-01
The assessment of eye lens doses for workers during interventional radiology (IR) procedures was performed using a new eye lens dosemeter. In parallel, the results of routine individual monitoring were analysed and compared with the results obtained from measurements with a new eye lens dosemeter. The eye lens doses were assessed using Hp(3) measured at the level of the eyes and were compared with Hp(10) measured with the whole-body dosemeter above the lead collar. The information about use of protective measures, the number of performed interventional procedures per month and their fluoroscopy time was also collected. The assessment of doses to the lens of the eye was done for 50 IR workers at 9 Lithuanian hospitals for the period of 2012-2013. If the use of lead glasses is not taken into account, the estimated maximum annual dose equivalent to the lens of the eye was 82 mSv. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Cukras, Catherine; Agrón, Elvira; Klein, Michael L; Ferris, Frederick L; Chew, Emily Y; Gensler, Gary; Wong, Wai T
2010-03-01
To describe the natural history of eyes with drusenoid pigment epithelial detachments (DPEDs) associated with age-related macular degeneration (AMD). Multicenter, clinic-based, prospective cohort study. Among 4757 participants enrolled in the Age-Related Eye Disease Study (AREDS), 255 were identified as having DPED in at least 1 eye and having 5 or more years of follow-up after the initial detection of the DPED. Baseline and annual fundus photographs were evaluated for the evolution of the fundus features and the development of advanced AMD in the forms of central geographic atrophy (CGA) or neovascular (NV) AMD. Kaplan-Meier analyses of progression to advanced AMD and of moderate vision loss (> or =15 letters compared with baseline) were performed. Rate of progression to advanced AMD and change in visual acuity from baseline (in terms of mean letters lost and proportion losing > or =15 letters). A total of 311 eyes (from 255 participants) with DPED were followed for a median follow-up time of 8 years subsequent to the initial detection of a DPED. Of the 282 eyes that did not have advanced AMD at baseline, advanced AMD developed within 5 years in 119 eyes (42%) (19% progressing to CGA and 23% progressing to NV-AMD). In the remaining eyes that did not develop advanced AMD (n=163), progressive fundus changes, typified by the development of calcified drusen and pigmentary changes, were detected. Visual decline was prominent among study eyes, with approximately 40% of all eyes decreasing in visual acuity by > or =15 letters at 5 years follow-up. Mean visual acuity decreased from 76 letters ( approximately 20/30) at baseline to 61 letters ( approximately 20/60) at 5 years. Five-year decreases in mean visual acuity averaged 26 letters for eyes progressing to advanced AMD and 8 letters for non-progressing eyes. The natural history of eyes containing DPED is characterized by a high rate of progression to both CGA and NV-AMD. Among eyes not progressing to advanced AMD, progressive development of pigmentary changes and calcified drusen were observed. Decline of visual acuity is a common outcome, with or without progression to advanced forms of AMD. Copyright 2010 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
The effect of autoimmune retinopathy on retinal vessel oxygen saturation.
Waizel, Maria; Türksever, Cengiz; Todorova, Margarita G
2018-05-22
To study the retinal vessel oxygen saturation alterations in patients with autoimmune retinopathy (AIR) and patients with autoimmune retinopathy associated with retinitis pigmentosa (AIR-RP) in comparison with healthy controls and patients with isolated retinitis pigmentosa (RP). Prospective, cross-sectional, and non-interventional study. Retinal vessel oximetry (RO) was performed on a total of 139 eyes: six eyes suffering from AIR and four eyes with AIR-RP were compared to 59 healthy control eyes and to 70 eyes with RP. A computer-based program of the retinal vessel analyser unit (IMEDOS Systems UG, Jena, Germany) was used to evaluate retinal vessel oxygen saturation. The mean oxygen saturation in the first and second branch retinal arterioles (A-SO 2 ) and venules (V-SO 2 ) were measured and their difference (A-V SO 2 ) was calculated. In addition, we measured the diameter of the retinal arterioles (D-A) and venules (D-V). Oxygen metabolism is altered in patients with isolated AIR and AIR-RP. Both, AIR and AIR-RP groups, differed from healthy controls showing significantly higher V-SO 2 values and significantly lower A-V SO 2 values (p < 0.025). In addition, the AIR-RP group could be differentiated from eyes suffering from isolated RP by means of significantly higher V-SO 2 values. Comparing retinal vessel diameters, both, the AIR and AIR-RP groups, presented with significant arterial (p = 0.05) and venular (p < 0.03) vessel attenuation than the healthy control group. Based on our results, in analogy to patients suffering from RP, oxygen metabolism seems to be altered in AIR patients.
'Reading the Mind in the Eyes': an fMRI study of adolescents with autism and their siblings.
Holt, R J; Chura, L R; Lai, M-C; Suckling, J; von dem Hagen, E; Calder, A J; Bullmore, E T; Baron-Cohen, S; Spencer, M D
2014-11-01
Mentalizing deficits are a hallmark of the autism spectrum condition (ASC) and a potential endophenotype for atypical social cognition in ASC. Differences in performance and neural activation on the 'Reading the Mind in the Eyes' task (the Eyes task) have been identified in individuals with ASC in previous studies. Performance on the Eyes task along with the associated neural activation was examined in adolescents with ASC (n = 50), their unaffected siblings (n = 40) and typically developing controls (n = 40). Based on prior literature that males and females with ASC display different cognitive and associated neural characteristics, analyses were stratified by sex. Three strategies were applied to test for endophenotypes at the level of neural activation: (1) identifying and locating conjunctions of ASC-control and sibling-control differences; (2) examining whether the sibling group is comparable to the ASC or intermediate between the ASC and control groups; and (3) examining spatial overlaps between ASC-control and sibling-control differences across multiple thresholds. Impaired behavioural performance on the Eyes task was observed in males with ASC compared to controls, but only at trend level in females; and no difference in performance was identified between sibling and same-sex control groups in both sexes. Neural activation showed a substantial endophenotype effect in the female groups but this was only modest in the male groups. Behavioural impairment on complex emotion recognition associated with mental state attribution is a phenotypic, rather than an endophenotypic, marker of ASC. However, the neural response during the Eyes task is a potential endophenotypic marker for ASC, particularly in females.
Is screening with digital imaging using one retinal view adequate?
Herbert, H M; Jordan, K; Flanagan, D W
2003-05-01
To compare the detection of diabetic retinopathy from digital images with slit-lamp biomicroscopy, and to determine whether British Diabetic Association (BDA) screening criteria are attained (>80% sensitivity, >95% specificity, &<5% technical failure). Diabetics referred for screening were studied in a prospective fashion. A single 45 degrees fundus image was obtained using the nonmydriatic digital camera. Each patient subsequently underwent slit-lamp biomicroscopy and diabetic retinopathy grading by a consultant ophthalmologist. Diabetic retinopathy and maculopathy was graded according to the Early Treatment of Diabetic Retinopathy Study. A total of 145 patients (288 eyes) were identified for screening. Of these, 26% of eyes had diabetic retinopathy, and eight eyes (3%) had sight-threatening diabetic retinopathy requiring treatment. The sensitivity for detection of any diabetic retinopathy was 38% and the specificity 95%. There was a 4% technical failure rate. There were 42/288 false negatives and 10/288 false positives. Of the 42 false negatives, 18 represented diabetic maculopathy, 20 represented peripheral diabetic retinopathy and four eyes had both macular and peripheral changes. Three eyes in the false-negative group (1% of total eyes) had sight-threatening retinopathy. There was good concordance between the two consultants (79% agreement on slit-lamp biomicroscopy and 84% on digital image interpretation). The specificity value and technical failure rate compare favourably with BDA guidelines. The low sensitivity for detection of any retinopathy reflects failure to detect minimal maculopathy and retinopathy outside the 45 degrees image. This could be improved by an additional nasal image and careful evaluation of macular images with a low threshold for slit-lamp biomicroscopy if image quality is poor.
Effect of optic neuritis on progressive axonal damage in multiple sclerosis patients.
Garcia-Martin, E; Pueyo, V; Ara, J R; Almarcegui, C; Martin, J; Pablo, L; Dolz, I; Sancho, E; Fernandez, F J
2011-07-01
The objective of this research was to study the effect of optic neuritis (ON) on axonal damage in multiple sclerosis (MS) patients. Specifically, we compared changes over 2 years in the retinal nerve fibre layer (RNFL) between affected and contralateral eyes in MS patients with a prior history of ON. Thirty-four patients with one unilateral definitive episode of ON were included and underwent a complete ophthalmic examination, optical coherence tomography (OCT), scanning laser polarimetry, visual evoked potentials (VEP) and pattern electroretinogram (pERG). All patients were re-evaluated at 12 and 24 months. Parameters were compared between ON-affected and contralateral eyes in an initial exploration and over the course of the follow-up. Correlations between parameter changes were analysed. RNFL thickness and functional parameters showed more affection in ON eyes (p ≤ 0.05), but changes in measurements during the study were similar between both groups of eyes. Progressive axonal loss can be detected in the optic nerve, but ON is not a risk factor for increased chronic damage in MS patients without ophthalmic relapses. Loss of the RNFL is caused by progressive degeneration associated with the disease.
Retinal and optical adaptations for nocturnal vision in the halictid bee Megalopta genalis.
Greiner, Birgit; Ribi, Willi A; Warrant, Eric J
2004-06-01
The apposition compound eye of a nocturnal bee, the halictid Megalopta genalis, is described for the first time. Compared to the compound eye of the worker honeybee Apis mellifera and the diurnal halictid bee Lasioglossum leucozonium, the eye of M. genalis shows specific retinal and optical adaptations for vision in dim light. The major anatomical adaptations within the eye of the nocturnal bee are (1) nearly twofold larger ommatidial facets and (2) a 4-5 times wider rhabdom diameter than found in the diurnal bees studied. Optically, the apposition eye of M. genalis is 27 times more sensitive to light than the eyes of the diurnal bees. This increased optical sensitivity represents a clear optical adaptation to low light intensities. Although this unique nocturnal apposition eye has a greatly improved ability to catch light, a 27-fold increase in sensitivity alone cannot account for nocturnal vision at light intensities that are 8 log units dimmer than during daytime. New evidence suggests that additional neuronal spatial summation within the first optic ganglion, the lamina, is involved.
Matsunaga, Koichi; Ito, Kunio; Esaki, Koji; Sugimoto, Kota; Sano, Toru; Miura, Katsuya; Sasoh, Mikio; Uji, Yukitaka
2004-12-01
To evaluate and compare the findings and changes of the anterior chamber angle configuration with indentation ultrasound biomicroscopy (UBM) gonioscopy in relative pupillary block (RPB), peripheral anterior synechia (PAS), and plateau iris configuration (PIC). This study included 73 eyes of 52 patients with RPB (n = 26), PAS (n = 21), or PIC (n = 26). First, a conventional UBM scan was performed using a normal size standard eye cup before indentation. Then, for indentation UBM gonioscopy, scans were performed using a new eye cup that we designed. For evaluation of the angle, angle opening distance 500 and angle recess area were recorded and evaluated with regard to the effect of expansion on the anterior chamber angle. Indentation UBM gonioscopy showed the characteristic images in each of the eyes. The angle of all examined eyes was significantly widened with indentation (P < 0.01). The angle changes in eyes with RPB were significantly greater than in eyes with PAS or PIC (P < 0.01). Indentation UBM gonioscopy is a very useful method for observing the angle and diagnosis of RPB, PAS, and PIC.
Autologous serum eye drops for dry eye
Pan, Qing; Angelina, Adla; Zambrano, Andrea; Marrone, Michael; Stark, Walter J; Heflin, Thomas; Tang, Li; Akpek, Esen K
2014-01-01
Background Theoretically, autologous serum eye drops (AS) have a potential advantage over traditional therapies based on the assumption that AS serve not only as a lacrimal substitute to provide lubrication, but also contain other biochemical components mimicking natural tears more closely. The application of AS in dry eye treatment has gained popularity as a second-line therapy in the treatment of dry eye. Published studies on the subject indicate that autologous serum could be an effective treatment for dry eye. Objectives To evaluate the efficacy and safety of AS compared to artificial tears for treating dry eye. Search methods We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library 2013, Issue 3), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLD MEDLINE, (January 1950 to April 2013), EMBASE (January 1980 to April 2013), Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to April 2013), the meta Register of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrials.gov) and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We also searched the Science Citation Index Expanded database (September 2013) and reference lists of included studies. We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 15 April 2013. Selection criteria We included randomized controlled trials (RCTs) in which AS was compared to artificial tears in the treatment of dry eye in adults. Data collection and analysis Two review authors independently screened all titles and abstracts and assessed full-text articles of potentially eligible trials. Two review authors extracted data and assessed the methodological quality and characteristics of the included trials.We contacted investigators for missing data. For both primary and secondary outcomes, we reported mean differences with corresponding 95% confidence intervals (CIs) for continuous outcomes. Main results We identified four eligible RCTs in which AS was compared with artificial tear treatment or saline in individuals (n = 72 participants) with dry eye of various etiologies (Sjögren’s syndrome-related dry eye, non-Sjögren’s syndrome dry eye and postoperative dry eye induced by laser-assisted in situ keratomileusis (LASIK)). The quality of the evidence provided by these trials was variable. A majority of the risk of bias domains were judged to have an unclear risk of bias in two trials owing to insufficient reporting of trial characteristics. One trial was considered to have a low risk of bias for most domains while another was considered to have a high risk of bias for most domains. Incomplete outcome reporting and heterogeneity in the participant populations and follow-up periods prevented the inclusion of these trials in a summary meta-analysis. For the primary outcome, improvement in participant-reported symptoms at one month, one trial (12 participants) showed no difference in participant-reported symptoms between 20% AS and artificial tears. Based on the results of two trials in 32 participants, 20% AS may provide some improvement in participant-reported symptoms compared to traditional artificial tears after two weeks of treatment. One trial also showed positive results with a mean difference in tear breakup time (TBUT) of 2.00 seconds (95% CI 0.99 to 3.01 seconds) between 20% AS and artificial tears after two weeks, which were not similar to findings from the other trials. Based on all other objective clinical assessments included in this review, AS was not associated with improvements in aqueous tear production measured by Schirmer’s test (two trials, 33 participants), ocular surface condition with fluorescein (four trials, 72 participants) or Rose Bengal staining (three trials, 60 participants), and epithelial metaplasia by impression cytology compared to artificial tears (one trial, 12 participants). Data on adverse effects were not reported by three of the included studies. In one study, there were no serious adverse events reported with the collection of and treatment with AS. Authors’ conclusions Overall there was inconsistency in the possible benefits of AS in improving participant-reported symptoms and TBUT and lack of effect based on other objective clinical measures. Well-planned, large, high-quality RCTs are warranted, in different severities of dry eye and using standardized questionnaires to measure participant-reported outcomes and objective clinical tests as well as objective biomarkers to assess the benefit of AS therapy for dry eye. PMID:23982997
Shimazaki, Jun; Seika, Den; Saga, Masamichi; Fukagawa, Kazumi; Sakata, Miki; Iwasaki, Miki; Okano, Takashi
2017-11-09
The purpose of the study was to compare the two mucin secretogogues, diquafosol (DQS) and rebamipide (RBM), for the treatment of dry eye syndrome (DES) in office workers. Dry eye patients using computers for >4 h/day were randomly assigned treatment with either DQS or RBM. Main outcomes measures included changes in tear film break-up time (TBUT) and subjective symptoms assessed by the Dry Eye-Related Quality of Life Score (DEQS). The subjects had scheduled examinations at 0 and 4 weeks, and the examinations at 2 and 8 weeks were optional. Changes in keratoconjunctival fluorescein score and a patient satisfaction questionnaire were also recorded. Both groups showed significant improvements in the DEQS scores at 2, 4, and 8 weeks following the initiation of the study. Both groups showed significant increases in the TBUT at 2 and 4 weeks. No significant difference was found between the DQS and RBM groups at any time periods. Patients reported more comfort with the use of DQS compared with the use of RBM. No local or systemic side effects were noted. The results of the present study indicated that both DQS and RBM were effective for the treatment of DES in office workers.
Kassab, A
2012-02-01
The ultrasonographic appearance and measurements of the normal buffalo and camel eye globes were described in 60 buffaloes (Bos bubalis) aged 1 year (28 eyes) and 10 years (32 eyes), and in 51 humped camels (Camelus dromedarius) aged 1 year (26 eyes) and 10 years (24 eyes). Ocular measurements were recorded by A- and B-scan ultrasonographic examination of 40 buffalo eyes (18 young and 22 adult eyes) and 34 camel eyes (14 young and 20 adult eyes) using a KANGH ultrasound scanner equipped with 10 MHz probe. For gross measurements, 20 buffalo and 16 camel eye globes were frozen and dissected and the same measurements were made using fine callipers macroscopically. The aqueous and vitreous humour of the buffalo and camel eyes appeared anechoic. The cornea, anterior and posterior lens capsule and iris appeared hyperechoic. The ocular measurements for the axial length, vitreous chamber depth (VCD), corneal thickness, lens thickness and scleroretinal rim thickness increase with the advance of age in both buffaloes and camels. Except for the anterior chamber depth, VCD and lens thickness, which were larger in adult camels than in adult buffaloes, no other differences between ocular dimensions were observed in both species. The results of this study are valuable for comparative ocular anatomy and will be useful for ultrasonographic evaluation of ocular diseases in buffaloes and camels. © 2011 Blackwell Verlag GmbH.