NASA Astrophysics Data System (ADS)
Sato, Eiichi; Abduraxit, Ablajan; Enomoto, Toshiyuki; Watanabe, Manabu; Hitomi, Keitaro; Takahashi, Kiyomi; Sato, Shigehiro; Ogawa, Akira; Onagawa, Jun
2010-04-01
An energy-discrimination K-edge x-ray computed tomography (CT) system is useful for controlling the image contrast of a target region by selecting both the photon energy and the energy width. The CT system has an oscillation-type linear cadmium telluride (CdTe) detectror. CT is performed by repeated linear scans and rotations of an object. Penetrating x-ray photons from the object are detected by a CdTe detector, and event signals of x-ray photons are produced using charge-sensitive and shaping amplifiers. Both photon energy and energy width are selected out using a multichannel analyzer, and the number of photons is counted by a counter card. In energy-discrimination CT, the tube voltage and tube current were 80 kV and 20 μA, respectively, and the x-ray intensity was 1.92 μGy/s at a distance of 1.0 m from the source and a tube voltage of 80 kV. The energy-discrimination CT was carried out by selecting x-ray photon energies.
Implicit prosody mining based on the human eye image capture technology
NASA Astrophysics Data System (ADS)
Gao, Pei-pei; Liu, Feng
2013-08-01
The technology of eye tracker has become the main methods of analyzing the recognition issues in human-computer interaction. Human eye image capture is the key problem of the eye tracking. Based on further research, a new human-computer interaction method introduced to enrich the form of speech synthetic. We propose a method of Implicit Prosody mining based on the human eye image capture technology to extract the parameters from the image of human eyes when reading, control and drive prosody generation in speech synthesis, and establish prosodic model with high simulation accuracy. Duration model is key issues for prosody generation. For the duration model, this paper put forward a new idea for obtaining gaze duration of eyes when reading based on the eye image capture technology, and synchronous controlling this duration and pronunciation duration in speech synthesis. The movement of human eyes during reading is a comprehensive multi-factor interactive process, such as gaze, twitching and backsight. Therefore, how to extract the appropriate information from the image of human eyes need to be considered and the gaze regularity of eyes need to be obtained as references of modeling. Based on the analysis of current three kinds of eye movement control model and the characteristics of the Implicit Prosody reading, relative independence between speech processing system of text and eye movement control system was discussed. It was proved that under the same text familiarity condition, gaze duration of eyes when reading and internal voice pronunciation duration are synchronous. The eye gaze duration model based on the Chinese language level prosodic structure was presented to change previous methods of machine learning and probability forecasting, obtain readers' real internal reading rhythm and to synthesize voice with personalized rhythm. This research will enrich human-computer interactive form, and will be practical significance and application prospect in terms of disabled assisted speech interaction. Experiments show that Implicit Prosody mining based on the human eye image capture technology makes the synthesized speech has more flexible expressions.
NASA Astrophysics Data System (ADS)
Zhu, Xiaotong; Li, Qingqing; Yu, Jinhua; Wu, Dan; Yao, Kai
2018-05-01
The geometric characteristics of tropical cyclone (TC) eyes before landfall in South China are examined using ground-based radar reflectivity. It is found that the median and mean eye area decrease with TC intensity, except for the severe typhoon category, and the eye size increases with height. The increasing rate of eye size is relatively greater in upper layers. Moreover, the ratio of eye size change in the vertical direction does not correlate with TC intensity. No relationship is presented between the ratio of eye size change in the vertical direction and the vertical wind shear. No relationship between the vertical change in eye size and the eye size at a certain level is found, inconsistent with other studies. No relationship exists between the vertical change in eye size and the intensity tendency. The eye roundness values range mainly from 0.5 to 0.7, and more intense TCs generally have eyes that are more circular.
Secrets in the eyes of Black Oystercatchers: A new sexing technique
Guzzetti, B.M.; Talbot, S.L.; Tessler, D.F.; Gill, V.A.; Murphy, E.C.
2008-01-01
Sexing oystercatchers in the field is difficult because males and females have identical plumage and are similar in size. Although Black Oystercatchers (Haematopus bachmani) are sexually dimorphic, using morphology to determine sex requires either capturing both pair members for comparison or using discriminant analyses to assign sex probabilistically based on morphometric traits. All adult Black Oystercatchers have bright yellow eyes, but some of them have dark specks, or eye flecks, in their irides. We hypothesized that this easily observable trait was sex-linked and could be used as a novel diagnostic tool for identifying sex. To test this, we compared data for oystercatchers from genetic molecular markers (CHD-W/CHD-Z and HINT-W/HINT-Z), morphometric analyses, and eye-fleck category (full eye flecks, slight eye flecks, and no eye flecks). Compared to molecular markers, we found that discriminant analyses based on morphological characteristics yielded variable results that were confounded by geographical differences in morphology. However, we found that eye flecks were sex-linked. Using an eye-fleck model where all females have full eye flecks and males have either slight eye flecks or no eye flecks, we correctly assigned the sex of 117 of 125 (94%) oystercatchers. Using discriminant analysis based on morphological characteristics, we correctly assigned the sex of 105 of 119 (88%) birds. Using the eye-fleck technique for sexing Black Oystercatchers may be preferable for some investigators because it is as accurate as discriminant analysis based on morphology and does not require capturing the birds. ??2008 Association of Field Ornithologists.
Kim, Sang Jin; Campbell, J Peter; Kalpathy-Cramer, Jayashree; Ostmo, Susan; Jonas, Karyn E; Choi, Dongseok; Chan, R V Paul; Chiang, Michael F
2018-06-01
Presence of plus disease in retinopathy of prematurity is the most critical element in identifying treatment-requiring disease. However, there is significant variability in plus disease diagnosis. In particular, plus disease has been defined as 2 or more quadrants of vascular abnormality, and it is not clear whether it is more reliably and accurately diagnosed by eye-based assessment of overall retinal appearance or by quadrant-based assessment combining grades of 4 individual quadrants. To compare eye-based vs quadrant-based diagnosis of plus disease and to provide insight for ophthalmologists about the diagnostic process. In this multicenter cohort study, we developed a database of 197 wide-angle retinal images from 141 preterm infants from neonatal intensive care units at 9 academic institutions (enrolled from July 2011 to December 2016). Each image was assigned a reference standard diagnosis based on consensus image-based and clinical diagnosis. Data analysis was performed from February 2017 to September 2017. Six graders independently diagnosed each of the 4 quadrants (cropped images) of the 197 eyes (quadrant-based diagnosis) as well as the entire image (eye-based diagnosis). Images were displayed individually, in random order. Quadrant-based diagnosis of plus disease was made when 2 or more quadrants were diagnosed as indicating plus disease by combining grades of individual quadrants post hoc. Intragrader and intergrader reliability (absolute agreement and κ statistic) and accuracy compared with the reference standard diagnosis. Of the 141 included preterm infants, 65 (46.1%) were female and 116 (82.3%) white, and the mean (SD) gestational age was 27.0 (2.6) weeks. There was variable agreement between eye-based and quadrant-based diagnosis among the 6 graders (Cohen κ range, 0.32-0.75). Four graders showed underdiagnosis of plus disease with quadrant-based diagnosis compared with eye-based diagnosis (by McNemar test). Intergrader agreement of quadrant-based diagnosis was lower than that of eye-based diagnosis (Fleiss κ, 0.75 [95% CI, 0.71-0.78] vs 0.55 [95% CI, 0.51-0.59]). The accuracy of eye-based diagnosis compared with the reference standard diagnosis was substantial to near-perfect, whereas that of quadrant-based plus disease diagnosis was only moderate to substantial for each grader. Graders had lower reliability and accuracy using quadrant-based diagnosis combining grades of individual quadrants than with eye-based diagnosis, suggesting that eye-based diagnosis has advantages over quadrant-based diagnosis. This has implications for more precise definitions of plus disease regarding the criterion of 2 or more quadrants, clinical care, computer-based image analysis, and education for all ophthalmologists who manage retinopathy of prematurity.
Cater, Kathleen C; Harbell, John W
2008-01-01
The bovine corneal opacity and permeability (BCOP) assay can be used to predict relative eye irritation potential of surfactant-based personal care formulations relative to a corporate benchmark. The human eye sting test is typically used to evaluate product claims of no tears/no stinging for children's bath products. A preliminary investigation was conducted to test a hypothesis that the BCOP assay could be used as a prediction model for relative ranking of human eye irritation responses under conditions of a standard human eye sting test to surfactant-based formulations. BCOP assays and human eye sting tests were conducted on 4 commercial and 1 prototype body wash (BW) developed specifically for children or as mild bath products. In the human eye sting test, 10 mul of a 10% dosing solution is instilled into one eye of each panelist (n = 20), and the contralateral eye is dosed with sterile water as a control. Bulbar conjunctival erythema responses of each eye are graded at 30 seconds by an ophthalmologist. The BCOP assay permeability values (optical density at 490 nm [OD(490)]) for the 5 BWs ranged from 0.438 to 1.252 (i.e., least to most irritating). By comparison, the number of panelists exhibiting erythema responses (mild to moderately pink) ranged from 3 of 20 panelists for the least irritating BW to 10 of 20 panelists for the most irritating BW tested. The relative ranking of eye irritation potential of the 5 BWs in the BCOP assay compares favorably with the relative ranking of the BWs in the human eye sting test. Based on these findings, the permeability endpoint of the BCOP assay, as described for surfactant-based formulations, showed promise as a prediction model for relative ranking of conjunctival erythema responses in the human eye. Consequently, screening of prototype formulations in the BCOP assay would allow for formula optimization of mild bath products prior to investment in a human eye sting test.
Segmentation method of eye region based on fuzzy logic system for classifying open and closed eyes
NASA Astrophysics Data System (ADS)
Kim, Ki Wan; Lee, Won Oh; Kim, Yeong Gon; Hong, Hyung Gil; Lee, Eui Chul; Park, Kang Ryoung
2015-03-01
The classification of eye openness and closure has been researched in various fields, e.g., driver drowsiness detection, physiological status analysis, and eye fatigue measurement. For a classification with high accuracy, accurate segmentation of the eye region is required. Most previous research used the segmentation method by image binarization on the basis that the eyeball is darker than skin, but the performance of this approach is frequently affected by thick eyelashes or shadows around the eye. Thus, we propose a fuzzy-based method for classifying eye openness and closure. First, the proposed method uses I and K color information from the HSI and CMYK color spaces, respectively, for eye segmentation. Second, the eye region is binarized using the fuzzy logic system based on I and K inputs, which is less affected by eyelashes and shadows around the eye. The combined image of I and K pixels is obtained through the fuzzy logic system. Third, in order to reflect the effect by all the inference values on calculating the output score of the fuzzy system, we use the revised weighted average method, where all the rectangular regions by all the inference values are considered for calculating the output score. Fourth, the classification of eye openness or closure is successfully made by the proposed fuzzy-based method with eye images of low resolution which are captured in the environment of people watching TV at a distance. By using the fuzzy logic system, our method does not require the additional procedure of training irrespective of the chosen database. Experimental results with two databases of eye images show that our method is superior to previous approaches.
Generating and Describing Affective Eye Behaviors
NASA Astrophysics Data System (ADS)
Mao, Xia; Li, Zheng
The manner of a person's eye movement conveys much about nonverbal information and emotional intent beyond speech. This paper describes work on expressing emotion through eye behaviors in virtual agents based on the parameters selected from the AU-Coded facial expression database and real-time eye movement data (pupil size, blink rate and saccade). A rule-based approach to generate primary (joyful, sad, angry, afraid, disgusted and surprise) and intermediate emotions (emotions that can be represented as the mixture of two primary emotions) utilized the MPEG4 FAPs (facial animation parameters) is introduced. Meanwhile, based on our research, a scripting tool, named EEMML (Emotional Eye Movement Markup Language) that enables authors to describe and generate emotional eye movement of virtual agents, is proposed.
Earle-Richardson, Giulia; Wyckoff, Lynae; Carrasquillo, Marilyn; Scribani, Melissa; Jenkins, Paul; May, John
2014-09-01
Eye irritation is a constant hazard for migrant and seasonal farmworkers, but there are few studies of the problem or how to address it. Researchers evaluated the effect of a community-based participatory eye health intervention on farmworker eye symptoms in the Hudson Valley, NY. A randomized pre-post intervention with 2, 4-week follow-up periods was implemented with a sample of 97 farmworkers. Five eye symptoms were measured, along with utilization of protective eyewear and eye drops. Leading baseline eye symptoms were redness (49%), blurred vision (43%), itching (43%), and eye pain (29%). Significant reductions in eye pain (P = 0.009), and non-significant reductions in redness were observed for the intervention group while controls experienced increases in both. The intervention was effective in significantly reducing eye pain, and to a lesser extent, redness. Future eyewear promotion programs should offer a range of eye wear, tailor offerings to local climate and tasks, evaluate eyewear durability, and include eye drops. © 2014 Wiley Periodicals, Inc.
Video-based eye tracking for neuropsychiatric assessment.
Adhikari, Sam; Stark, David E
2017-01-01
This paper presents a video-based eye-tracking method, ideally deployed via a mobile device or laptop-based webcam, as a tool for measuring brain function. Eye movements and pupillary motility are tightly regulated by brain circuits, are subtly perturbed by many disease states, and are measurable using video-based methods. Quantitative measurement of eye movement by readily available webcams may enable early detection and diagnosis, as well as remote/serial monitoring, of neurological and neuropsychiatric disorders. We successfully extracted computational and semantic features for 14 testing sessions, comprising 42 individual video blocks and approximately 17,000 image frames generated across several days of testing. Here, we demonstrate the feasibility of collecting video-based eye-tracking data from a standard webcam in order to assess psychomotor function. Furthermore, we were able to demonstrate through systematic analysis of this data set that eye-tracking features (in particular, radial and tangential variance on a circular visual-tracking paradigm) predict performance on well-validated psychomotor tests. © 2017 New York Academy of Sciences.
NASA Astrophysics Data System (ADS)
Zhang, Lai-xian; Sun, Hua-yan; Zhao, Yan-zhong; Zheng, Yong-hui; Shan, Cong-miao
2013-08-01
Based on the cat-eye effect of optical system, free space optical communication based on cat-eye modulating retro-reflector can build communication link rapidly. Compared to classical free space optical communication system, system based on cat-eye modulating retro-reflector has great advantages such as building communication link more rapidly, a passive terminal is smaller, lighter and lower power consuming. The incident angle is an important factor of cat-eye effect, so it will affect the retro-reflecting communication link. In this paper, the principle and work flow of free space optical communication based on cat-eye modulating retro-reflector were introduced. Then, using the theory of geometric optics, the equivalent model of modulating retro-reflector with incidence angle was presented. The analytical solution of active area and retro-reflected light intensity of cat-eye modulating retro-reflector were given. Noise of PIN photodetector was analyzed, based on which, bit error rate of free space optical communication based on cat-eye modulating retro-reflector was presented. Finally, simulations were done to study the effect of incidence angle to the communication. The simulation results show that the incidence angle has little effect on active area and retro-reflected light intensity when the incidence beam is in the active field angle of cat-eye modulating retro-reflector. With certain system and condition, the communication link can rapidly be built when the incidence light beam is in the field angle, and the bit error rate increases greatly with link range. When link range is smaller than 35Km, the bit error rate is less than 10-16.
Park, Yong Seok; Heo, Hwan; Ye, Byeong Jin; Suh, Young-Woo; Kim, Seung-Hyun; Park, Shin Hae; Lim, Key Hwan; Lee, Sung Jin; Park, Song Hee; Baek, Seung-Hee
2017-02-01
To estimate the factors and prevalence of eye care service utilization in the South Korean population. This cross-sectional, population-based study included data from 22,550 Koreans aged ≥5 years who participated in the Korea National Health and Nutrition Examination Survey from 2010 to 2012. For people aged 5 to 11 years (young children), information was based on self-reports of contact with eye care service in the past year; for people aged ≥12 years (older population), the information was based on the self-reported lifetime contact with eye care service. Univariate and multivariate logistic regression analyses of the complex sample survey data were performed. The prevalence of eye care service use in young children during the past year was 61.1% (95% confidence interval, 58.1%-64.1%), while that in the older population during their lifetime was 73.5%. Subjects aged 7 to 11 years were more likely to have had an eye examination in the past year than subjects aged 5 to 6 years (odds ratio, 3.83; 95% confidence interval, 2.37-6.19). Multivariate logistic regression analysis indicated that higher monthly household income, being a National Health Insurance holder, and having private health insurance were related to more frequent use of eye care services in young children. For the older population and women, those living in an urban area and those with a best-corrected visual acuity less than 20 / 40 in the worse-seeing eye were more likely to have had an eye examination during their lifetime. Low education level was associated with low lifetime use of eye care services in the older population. There are sociodemographic disparities with use of eye care services in South Korea. This population-based study provides information that is useful for determining different intervention programs based on sociodemographic disparities to promote eye care service utilization in South Korea.
S V, Mahesh Kumar; R, Gunasundari
2018-06-02
Eye disease is a major health problem among the elderly people. Cataract and corneal arcus are the major abnormalities that exist in the anterior segment eye region of aged people. Hence, computer-aided diagnosis of anterior segment eye abnormalities will be helpful for mass screening and grading in ophthalmology. In this paper, we propose a multiclass computer-aided diagnosis (CAD) system using visible wavelength (VW) eye images to diagnose anterior segment eye abnormalities. In the proposed method, the input VW eye images are pre-processed for specular reflection removal and the iris circle region is segmented using a circular Hough Transform (CHT)-based approach. The first-order statistical features and wavelet-based features are extracted from the segmented iris circle and used for classification. The Support Vector Machine (SVM) by Sequential Minimal Optimization (SMO) algorithm was used for the classification. In experiments, we used 228 VW eye images that belong to three different classes of anterior segment eye abnormalities. The proposed method achieved a predictive accuracy of 96.96% with 97% sensitivity and 99% specificity. The experimental results show that the proposed method has significant potential for use in clinical applications.
Geometry and Gesture-Based Features from Saccadic Eye-Movement as a Biometric in Radiology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hammond, Tracy; Tourassi, Georgia; Yoon, Hong-Jun
In this study, we present a novel application of sketch gesture recognition on eye-movement for biometric identification and estimating task expertise. The study was performed for the task of mammographic screening with simultaneous viewing of four coordinated breast views as typically done in clinical practice. Eye-tracking data and diagnostic decisions collected for 100 mammographic cases (25 normal, 25 benign, 50 malignant) and 10 readers (three board certified radiologists and seven radiology residents), formed the corpus for this study. Sketch gesture recognition techniques were employed to extract geometric and gesture-based features from saccadic eye-movements. Our results show that saccadic eye-movement, characterizedmore » using sketch-based features, result in more accurate models for predicting individual identity and level of expertise than more traditional eye-tracking features.« less
A laser-based eye-tracking system.
Irie, Kenji; Wilson, Bruce A; Jones, Richard D; Bones, Philip J; Anderson, Tim J
2002-11-01
This paper reports on the development of a new eye-tracking system for noninvasive recording of eye movements. The eye tracker uses a flying-spot laser to selectively image landmarks on the eye and, subsequently, measure horizontal, vertical, and torsional eye movements. Considerable work was required to overcome the adverse effects of specular reflection of the flying-spot from the surface of the eye onto the sensing elements of the eye tracker. These effects have been largely overcome, and the eye-tracker has been used to document eye movement abnormalities, such as abnormal torsional pulsion of saccades, in the clinical setting.
Kim, Ki Wan; Hong, Hyung Gil; Nam, Gi Pyo; Park, Kang Ryoung
2017-06-30
The necessity for the classification of open and closed eyes is increasing in various fields, including analysis of eye fatigue in 3D TVs, analysis of the psychological states of test subjects, and eye status tracking-based driver drowsiness detection. Previous studies have used various methods to distinguish between open and closed eyes, such as classifiers based on the features obtained from image binarization, edge operators, or texture analysis. However, when it comes to eye images with different lighting conditions and resolutions, it can be difficult to find an optimal threshold for image binarization or optimal filters for edge and texture extraction. In order to address this issue, we propose a method to classify open and closed eye images with different conditions, acquired by a visible light camera, using a deep residual convolutional neural network. After conducting performance analysis on both self-collected and open databases, we have determined that the classification accuracy of the proposed method is superior to that of existing methods.
ERIC Educational Resources Information Center
Asfar, Taghrid; Lee, David J.; Lam, Byron L.; Murchison, Ann P.; Mayro, Eileen L.; Owsley, Cynthia; McGwin, Gerald; Gower, Emily W.; Friedman, David S.; Saaddine, Jinan
2018-01-01
Background: Smoking causes blindness-related diseases. Eye-care providers are uniquely positioned to help their patients quit smoking. Aims: Using a pre-/postevaluation design, this study evaluated a web-based training in smoking cessation counseling targeting eye-care providers. Method: The training was developed based on the 3A1R protocol:…
Statistical virtual eye model based on wavefront aberration
Wang, Jie-Mei; Liu, Chun-Ling; Luo, Yi-Ning; Liu, Yi-Guang; Hu, Bing-Jie
2012-01-01
Wavefront aberration affects the quality of retinal image directly. This paper reviews the representation and reconstruction of wavefront aberration, as well as the construction of virtual eye model based on Zernike polynomial coefficients. In addition, the promising prospect of virtual eye model is emphasized. PMID:23173112
Asiedu, Kofi; Kyei, Samuel; Ayobi, Benedict; Agyemang, Frank Okyere; Ablordeppey, Reynolds Kwame
2016-12-01
This study sought to provide an evidence-based profile of the diagnosis, treatment and knowledge or opinions on dry eye among optometrists and ophthalmologists in Ghana. This was a cross-sectional survey RESULTS: The responses of 162 participants are included in the analysis. The most commonly used test to diagnosed dry eye disease was tear break-up time followed by patient history. The most common symptom doctors heard from dry eye patients were burning sensation followed by foreign body sensation. The most often prescribed first- line treatment for dry eye was aqueous-based artificial tears followed by lipid-based artificial tears. Most practitioners considered meibomian gland dysfunction as the most common cause of dry eye followed by pterygium. The most often used test to guide or gauge therapeutic effect is patient history followed closely by tear break-up time. Most practitioners reported that 10%-20% of all their patients they see in a day are diagnosed of dry eye. This study showed tear break up time was the main test majority of practitioners in Ghana used to diagnose dry eye but patient history was the main test used to gauge therapeutic effect over time. Burning sensation was the commonest symptom practitioners heard from dry eye patients whilst artificial tears was their main and first-line treatment for dry eye. Copyright © 2016 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Veselovskaya, N N; Zherebko, I B
Conducted a comparative analysis of functional changes in tear production in patients with dry eye syndrome and endocrine ophthalmopathy in the conditions of the long-term acting of preservative free medications based on natural substances. A total of 30 people, aged 35 to 53 years old with clinical manifestations of DES on the background of EO were divided on two groups. In I group eye drops of ectoine and in II - artificial tears were administered. The examination included general and specific methods. The term of follow up - 30 days. It was found that long-term use of preservative free eye drops based on ectoine leads to more expressive positive changes in the condition of the anterior surface of the eye and the secretion and quality of the tear.
NASA Astrophysics Data System (ADS)
Santamaría, Beatriz; Laguna, María. Fe; López-Romero, David; López-Hernandez, A.; Sanza, F. J.; Lavín, A.; Casquel, R.; Maigler, M.; Holgado, M.
2018-02-01
A novel compact optical biochip based on a thin layer-sensing BICELL surface of nitrocellulose is used for in-situ labelfree detection of dry eye disease (DED). In this work the development of a compact biosensor that allows obtaining quantitative diagnosis with a limited volume of sample is reported. The designed sensors can be analyzed with an optical integrated Point-of-Care read-out system based on the "Increase Relative Optical Power" principle which enhances the performance and Limit of Detection. Several proteins involved with dry eye dysfunction have been validated as biomarkers. Presented biochip analyzes three of those biomarkers: MMP9, S100A6 and CST4. BICELLs based on nitrocellulose permit to immobilize antibodies for each biomarker recognition. The optical response obtained from the biosensor through the readout platform is capable to recognize specifically the desired proteins in the concentrations range for control eye (CE) and dry eye syndrome (DES). Preliminary results obtained will allow the development of a dry eye detection device useful in the area of ophthalmology and applicable to other possible diseases related to the eye dysfunction.
Shinozaki, Takahiro
2018-01-01
Human-computer interface systems whose input is based on eye movements can serve as a means of communication for patients with locked-in syndrome. Eye-writing is one such system; users can input characters by moving their eyes to follow the lines of the strokes corresponding to characters. Although this input method makes it easy for patients to get started because of their familiarity with handwriting, existing eye-writing systems suffer from slow input rates because they require a pause between input characters to simplify the automatic recognition process. In this paper, we propose a continuous eye-writing recognition system that achieves a rapid input rate because it accepts characters eye-written continuously, with no pauses. For recognition purposes, the proposed system first detects eye movements using electrooculography (EOG), and then a hidden Markov model (HMM) is applied to model the EOG signals and recognize the eye-written characters. Additionally, this paper investigates an EOG adaptation that uses a deep neural network (DNN)-based HMM. Experiments with six participants showed an average input speed of 27.9 character/min using Japanese Katakana as the input target characters. A Katakana character-recognition error rate of only 5.0% was achieved using 13.8 minutes of adaptation data. PMID:29425248
Eye Health and Safety Among Latino Farmworkers
Verma, Amit; Schulz, Mark R.; Quandt, Sara A.; Robinson, Erin N.; Grzywacz, Joseph G.; Chen, Haiying; Arcury, Thomas A.
2011-01-01
Farmworkers face a variety of risk factors for eye injuries. Measures of eye protection use and of eye safety knowledge and beliefs are based on a survey of 300 Latino farmworkers in North Carolina. Few farmworkers report using eye protection (8.3%); most (92.3%) report that employers do not provide eye protection. Approximately 70% report that they are not trained in preventing eye injuries; 81% believe that their chances of getting an eye injury are low. Many farmworkers choose to take risks in order to save time. Interventions are needed that target farmworker knowledge and beliefs about eye safety. PMID:21462026
Intraocular lens based on double-liquid variable-focus lens.
Peng, Runling; Li, Yifan; Hu, Shuilan; Wei, Maowei; Chen, Jiabi
2014-01-10
In this work, the crystalline lens in the Gullstrand-Le Grand human eye model is replaced by a double-liquid variable-focus lens, the structure data of which are based on theoretical analysis and experimental results. When the pseudoaphakic eye is built in Zemax, aspherical surfaces are introduced to the double-liquid variable-focus lens to reduce the axial spherical aberration existent in the system. After optimization, the zoom range of the pseudoaphakic eye greatly exceeds that of normal human eyes, and the spot size on an image plane basically reaches the normal human eye's limit of resolution.
Rotational symmetric HMD with eye-tracking capability
NASA Astrophysics Data System (ADS)
Liu, Fangfang; Cheng, Dewen; Wang, Qiwei; Wang, Yongtian
2016-10-01
As an important auxiliary function of head-mounted displays (HMDs), eye tracking has an important role in the field of intelligent human-machine interaction. In this paper, an eye-tracking HMD system (ET-HMD) is designed based on the rotational symmetric system. The tracking principle in this paper is based on pupil-corneal reflection. The ET-HMD system comprises three optical paths for virtual display, infrared illumination, and eye tracking. The display optics is shared by three optical paths and consists of four spherical lenses. For the eye-tracking path, an extra imaging lens is added to match the image sensor and achieve eye tracking. The display optics provides users a 40° diagonal FOV with a ״ 0.61 OLED, the 19 mm eye clearance, and 10 mm exit pupil diameter. The eye-tracking path can capture 15 mm × 15 mm of the users' eyes. The average MTF is above 0.1 at 26 lp/mm for the display path, and exceeds 0.2 at 46 lp/mm for the eye-tracking path. Eye illumination is simulated using LightTools with an eye model and an 850 nm near-infrared LED (NIR-LED). The results of the simulation show that the illumination of the NIR-LED can cover the area of the eye model with the display optics that is sufficient for eye tracking. The integrated optical system HMDs with eye-tracking feature can help improve the HMD experience of users.
iTemplate: A template-based eye movement data analysis approach.
Xiao, Naiqi G; Lee, Kang
2018-02-08
Current eye movement data analysis methods rely on defining areas of interest (AOIs). Due to the fact that AOIs are created and modified manually, variances in their size, shape, and location are unavoidable. These variances affect not only the consistency of the AOI definitions, but also the validity of the eye movement analyses based on the AOIs. To reduce the variances in AOI creation and modification and achieve a procedure to process eye movement data with high precision and efficiency, we propose a template-based eye movement data analysis method. Using a linear transformation algorithm, this method registers the eye movement data from each individual stimulus to a template. Thus, users only need to create one set of AOIs for the template in order to analyze eye movement data, rather than creating a unique set of AOIs for all individual stimuli. This change greatly reduces the error caused by the variance from manually created AOIs and boosts the efficiency of the data analysis. Furthermore, this method can help researchers prepare eye movement data for some advanced analysis approaches, such as iMap. We have developed software (iTemplate) with a graphic user interface to make this analysis method available to researchers.
Full 3-D OCT-based pseudophakic custom computer eye model
Sun, M.; Pérez-Merino, P.; Martinez-Enriquez, E.; Velasco-Ocana, M.; Marcos, S.
2016-01-01
We compared measured wave aberrations in pseudophakic eyes implanted with aspheric intraocular lenses (IOLs) with simulated aberrations from numerical ray tracing on customized computer eye models, built using quantitative 3-D OCT-based patient-specific ocular geometry. Experimental and simulated aberrations show high correlation (R = 0.93; p<0.0001) and similarity (RMS for high order aberrations discrepancies within 23.58%). This study shows that full OCT-based pseudophakic custom computer eye models allow understanding the relative contribution of optical geometrical and surgically-related factors to image quality, and are an excellent tool for characterizing and improving cataract surgery. PMID:27231608
The Perfect Eye A Novel Model for Teaching the Theory of Refraction.
ERIC Educational Resources Information Center
Kurtz, Daniel
1999-01-01
The Perfect Eye model simplifies solutions to a wide variety of optometry instructional problems by facilitating student understanding of the interaction among lenses, objects, accommodation, and ametropia. The model is based on the premise that inside every eye is a perfect (emmetropic) eye, and that the physiological eye is a combination of the…
A Study of Deep CNN-Based Classification of Open and Closed Eyes Using a Visible Light Camera Sensor
Kim, Ki Wan; Hong, Hyung Gil; Nam, Gi Pyo; Park, Kang Ryoung
2017-01-01
The necessity for the classification of open and closed eyes is increasing in various fields, including analysis of eye fatigue in 3D TVs, analysis of the psychological states of test subjects, and eye status tracking-based driver drowsiness detection. Previous studies have used various methods to distinguish between open and closed eyes, such as classifiers based on the features obtained from image binarization, edge operators, or texture analysis. However, when it comes to eye images with different lighting conditions and resolutions, it can be difficult to find an optimal threshold for image binarization or optimal filters for edge and texture extraction. In order to address this issue, we propose a method to classify open and closed eye images with different conditions, acquired by a visible light camera, using a deep residual convolutional neural network. After conducting performance analysis on both self-collected and open databases, we have determined that the classification accuracy of the proposed method is superior to that of existing methods. PMID:28665361
Assessment of Eye Fatigue Caused by 3D Displays Based on Multimodal Measurements
Bang, Jae Won; Heo, Hwan; Choi, Jong-Suk; Park, Kang Ryoung
2014-01-01
With the development of 3D displays, user's eye fatigue has been an important issue when viewing these displays. There have been previous studies conducted on eye fatigue related to 3D display use, however, most of these have employed a limited number of modalities for measurements, such as electroencephalograms (EEGs), biomedical signals, and eye responses. In this paper, we propose a new assessment of eye fatigue related to 3D display use based on multimodal measurements. compared to previous works Our research is novel in the following four ways: first, to enhance the accuracy of assessment of eye fatigue, we measure EEG signals, eye blinking rate (BR), facial temperature (FT), and a subjective evaluation (SE) score before and after a user watches a 3D display; second, in order to accurately measure BR in a manner that is convenient for the user, we implement a remote gaze-tracking system using a high speed (mega-pixel) camera that measures eye blinks of both eyes; thirdly, changes in the FT are measured using a remote thermal camera, which can enhance the measurement of eye fatigue, and fourth, we perform various statistical analyses to evaluate the correlation between the EEG signal, eye BR, FT, and the SE score based on the T-test, correlation matrix, and effect size. Results show that the correlation of the SE with other data (FT, BR, and EEG) is the highest, while those of the FT, BR, and EEG with other data are second, third, and fourth highest, respectively. PMID:25192315
Optimizations and Applications in Head-Mounted Video-Based Eye Tracking
ERIC Educational Resources Information Center
Li, Feng
2011-01-01
Video-based eye tracking techniques have become increasingly attractive in many research fields, such as visual perception and human-computer interface design. The technique primarily relies on the positional difference between the center of the eye's pupil and the first-surface reflection at the cornea, the corneal reflection (CR). This…
System for assisted mobility using eye movements based on electrooculography.
Barea, Rafael; Boquete, Luciano; Mazo, Manuel; López, Elena
2002-12-01
This paper describes an eye-control method based on electrooculography (EOG) to develop a system for assisted mobility. One of its most important features is its modularity, making it adaptable to the particular needs of each user according to the type and degree of handicap involved. An eye model based on electroculographic signal is proposed and its validity is studied. Several human-machine interfaces (HMI) based on EOG are commented, focusing our study on guiding and controlling a wheelchair for disabled people, where the control is actually effected by eye movements within the socket. Different techniques and guidance strategies are then shown with comments on the advantages and disadvantages of each one. The system consists of a standard electric wheelchair with an on-board computer, sensors and a graphic user interface run by the computer. On the other hand, this eye-control method can be applied to handle graphical interfaces, where the eye is used as a mouse computer. Results obtained show that this control technique could be useful in multiple applications, such as mobility and communication aid for handicapped persons.
Preparation and evaluation of HPMC-based pirfenidone solution in vivo.
Yang, Mei; Yang, Yang-Fan; Lei, Ming; Ye, Cheng-Tian; Zhao, Chun-Shun; Xu, Jian-Gang; Wu, Kai-Li; Yu, Min-Bin
2017-01-01
Pirfenidone (PFD) has exhibited therapeutic potential in the treatment of cell proliferative disorders. The previously developed 0.5% water-based PFD eye drops by our team exhibited antiscarring effectiveness and ocular safety but with a limit of short half-life and poor bioavailability. To increase bioavailability of the water-based PFD eye drops, we prepared a viscous solution by adding hydroxypropyl methylcellulose (HPMC, F4M), which acted as a viscosity-enhancer. Subsequently, we compared the HPMC-based PFD solution with the water-based PFD eye drops. PFD solution with 1% HPMC (w/v) was prepared, and the viscosities at different shear rates were measured to investigate its rheology. PFD concentrations in the tear, aqueous humor, conjunctiva, cornea, and sclerae of New Zealand rabbits were detected at different time points with high-performance liquid chromatography (HPLC) following single instillation of the 0.5% PFD (w/v) water-based eye drops or HPMC-based solution. Compared with the 0.5% water-based PFD eye drops, the HPMC-based solution increased the PFD levels in tears and prolonged the residence time from 10 to more than 20 min (p < .01). Consequently, the concentrations of PFD in aqueous humor, conjunctiva, cornea, and sclera were elevated to varying degrees until 90 min after topical administration. The developed formulation possesses a same readily administration and simple preparation as the PFD eye drops; however, the HPMC-based solution exhibited the higher bioavailability.
NASA Technical Reports Server (NTRS)
Das, V. E.; Thomas, C. W.; Zivotofsky, A. Z.; Leigh, R. J.
1996-01-01
Video-based eye-tracking systems are especially suited to studying eye movements during naturally occurring activities such as locomotion, but eye velocity records suffer from broad band noise that is not amenable to conventional filtering methods. We evaluated the effectiveness of combined median and moving-average filters by comparing prefiltered and postfiltered records made synchronously with a video eye-tracker and the magnetic search coil technique, which is relatively noise free. Root-mean-square noise was reduced by half, without distorting the eye velocity signal. To illustrate the practical use of this technique, we studied normal subjects and patients with deficient labyrinthine function and compared their ability to hold gaze on a visual target that moved with their heads (cancellation of the vestibulo-ocular reflex). Patients and normal subjects performed similarly during active head rotation but, during locomotion, patients held their eyes more steadily on the visual target than did subjects.
Changing trends in the treatment of dry-eye disease.
Dogru, Murat; Nakamura, Masatsugu; Shimazaki, Jun; Tsubota, Kazuo
2013-12-01
Dry eye is a visually disabling disease encountered in many countries with a wide variation of treatment practices all over the world. On that front, the 2007 Report of the International Dry Eye WorkShop (DEWS) reviewed the current knowledge on all aspects of dry-eye disease (DED), in an evidence-based manner, and outlined the trends and recommendations in the treatment of DED on the basis of disease severity. This review mainly focuses on treatments for DED based on severity as recommended in the DEWS report, particularly artificial eye drops, hyaluronate sodium eye drops, autologous serum, anti-inflammatory eye drops including cyclosporine and steroids, and mucin secretagogues. New dry-eye treatment modalities in current trials outlined on the clinicaltrial.gov site are also outlined. Further investigations into the mechanism of action of the new mucin and tear secretagogues which have been suggested to have anti-inflammatory properties will enrich our understanding in relation to relevant ocular surface responses after treatment with these new agents.
On Biometrics With Eye Movements.
Zhang, Youming; Juhola, Martti
2017-09-01
Eye movements are a relatively novel data source for biometric identification. When video cameras applied to eye tracking become smaller and more efficient, this data source could offer interesting opportunities for the development of eye movement biometrics. In this paper, we study primarily biometric identification as seen as a classification task of multiple classes, and secondarily biometric verification considered as binary classification. Our research is based on the saccadic eye movement signal measurements from 109 young subjects. In order to test the data measured, we use a procedure of biometric identification according to the one-versus-one (subject) principle. In a development from our previous research, which also involved biometric verification based on saccadic eye movements, we now apply another eye movement tracker device with a higher sampling frequency of 250 Hz. The results obtained are good, with correct identification rates at 80-90% at their best.
Eye movement identification based on accumulated time feature
NASA Astrophysics Data System (ADS)
Guo, Baobao; Wu, Qiang; Sun, Jiande; Yan, Hua
2017-06-01
Eye movement is a new kind of feature for biometrical recognition, it has many advantages compared with other features such as fingerprint, face, and iris. It is not only a sort of static characteristics, but also a combination of brain activity and muscle behavior, which makes it effective to prevent spoofing attack. In addition, eye movements can be incorporated with faces, iris and other features recorded from the face region into multimode systems. In this paper, we do an exploring study on eye movement identification based on the eye movement datasets provided by Komogortsev et al. in 2011 with different classification methods. The time of saccade and fixation are extracted from the eye movement data as the eye movement features. Furthermore, the performance analysis was conducted on different classification methods such as the BP, RBF, ELMAN and SVM in order to provide a reference to the future research in this field.
Eye gazing direction inspection based on image processing technique
NASA Astrophysics Data System (ADS)
Hao, Qun; Song, Yong
2005-02-01
According to the research result in neural biology, human eyes can obtain high resolution only at the center of view of field. In the research of Virtual Reality helmet, we design to detect the gazing direction of human eyes in real time and feed it back to the control system to improve the resolution of the graph at the center of field of view. In the case of current display instruments, this method can both give attention to the view field of virtual scene and resolution, and improve the immersion of virtual system greatly. Therefore, detecting the gazing direction of human eyes rapidly and exactly is the basis of realizing the design scheme of this novel VR helmet. In this paper, the conventional method of gazing direction detection that based on Purklinje spot is introduced firstly. In order to overcome the disadvantage of the method based on Purklinje spot, this paper proposed a method based on image processing to realize the detection and determination of the gazing direction. The locations of pupils and shapes of eye sockets change with the gazing directions. With the aid of these changes, analyzing the images of eyes captured by the cameras, gazing direction of human eyes can be determined finally. In this paper, experiments have been done to validate the efficiency of this method by analyzing the images. The algorithm can carry out the detection of gazing direction base on normal eye image directly, and it eliminates the need of special hardware. Experiment results show that the method is easy to implement and have high precision.
Extracting hurricane eye morphology from spaceborne SAR images using morphological analysis
NASA Astrophysics Data System (ADS)
Lee, Isabella K.; Shamsoddini, Ali; Li, Xiaofeng; Trinder, John C.; Li, Zeyu
2016-07-01
Hurricanes are among the most destructive global natural disasters. Thus recognizing and extracting their morphology is important for understanding their dynamics. Conventional optical sensors, due to cloud cover associated with hurricanes, cannot reveal the intense air-sea interaction occurring at the sea surface. In contrast, the unique capabilities of spaceborne synthetic aperture radar (SAR) data for cloud penetration, and its backscattering signal characteristics enable the extraction of the sea surface roughness. Therefore, SAR images enable the measurement of the size and shape of hurricane eyes, which reveal their evolution and strength. In this study, using six SAR hurricane images, we have developed a mathematical morphology method for automatically extracting the hurricane eyes from C-band SAR data. Skeleton pruning based on discrete skeleton evolution (DSE) was used to ensure global and local preservation of the hurricane eye shape. This distance weighted algorithm applied in a hierarchical structure for extraction of the edges of the hurricane eyes, can effectively avoid segmentation errors by reducing redundant skeletons attributed to speckle noise along the edges of the hurricane eye. As a consequence, the skeleton pruning has been accomplished without deficiencies in the key hurricane eye skeletons. A morphology-based analyses of the subsequent reconstructions of the hurricane eyes shows a high degree of agreement with the hurricane eye areas derived from reference data based on NOAA manual work.
Design of a Gaze-Sensitive Virtual Social Interactive System for Children With Autism
Lahiri, Uttama; Warren, Zachary; Sarkar, Nilanjan
2013-01-01
Impairments in social communication skills are thought to be core deficits in children with autism spectrum disorder (ASD). In recent years, several assistive technologies, particularly Virtual Reality (VR), have been investigated to promote social interactions in this population. It is well known that children with ASD demonstrate atypical viewing patterns during social interactions and thus monitoring eye-gaze can be valuable to design intervention strategies. While several studies have used eye-tracking technology to monitor eye-gaze for offline analysis, there exists no real-time system that can monitor eye-gaze dynamically and provide individualized feedback. Given the promise of VR-based social interaction and the usefulness of monitoring eye-gaze in real-time, a novel VR-based dynamic eye-tracking system is developed in this work. This system, called Virtual Interactive system with Gaze-sensitive Adaptive Response Technology (VIGART), is capable of delivering individualized feedback based on a child’s dynamic gaze patterns during VR-based interaction. Results from a usability study with six adolescents with ASD are presented that examines the acceptability and usefulness of VIGART. The results in terms of improvement in behavioral viewing and changes in relevant eye physiological indexes of participants while interacting with VIGART indicate the potential of this novel technology. PMID:21609889
Design of a gaze-sensitive virtual social interactive system for children with autism.
Lahiri, Uttama; Warren, Zachary; Sarkar, Nilanjan
2011-08-01
Impairments in social communication skills are thought to be core deficits in children with autism spectrum disorder (ASD). In recent years, several assistive technologies, particularly Virtual Reality (VR), have been investigated to promote social interactions in this population. It is well known that children with ASD demonstrate atypical viewing patterns during social interactions and thus monitoring eye-gaze can be valuable to design intervention strategies. While several studies have used eye-tracking technology to monitor eye-gaze for offline analysis, there exists no real-time system that can monitor eye-gaze dynamically and provide individualized feedback. Given the promise of VR-based social interaction and the usefulness of monitoring eye-gaze in real-time, a novel VR-based dynamic eye-tracking system is developed in this work. This system, called Virtual Interactive system with Gaze-sensitive Adaptive Response Technology (VIGART), is capable of delivering individualized feedback based on a child's dynamic gaze patterns during VR-based interaction. Results from a usability study with six adolescents with ASD are presented that examines the acceptability and usefulness of VIGART. The results in terms of improvement in behavioral viewing and changes in relevant eye physiological indexes of participants while interacting with VIGART indicate the potential of this novel technology. © 2011 IEEE
Vision-based method for detecting driver drowsiness and distraction in driver monitoring system
NASA Astrophysics Data System (ADS)
Jo, Jaeik; Lee, Sung Joo; Jung, Ho Gi; Park, Kang Ryoung; Kim, Jaihie
2011-12-01
Most driver-monitoring systems have attempted to detect either driver drowsiness or distraction, although both factors should be considered for accident prevention. Therefore, we propose a new driver-monitoring method considering both factors. We make the following contributions. First, if the driver is looking ahead, drowsiness detection is performed; otherwise, distraction detection is performed. Thus, the computational cost and eye-detection error can be reduced. Second, we propose a new eye-detection algorithm that combines adaptive boosting, adaptive template matching, and blob detection with eye validation, thereby reducing the eye-detection error and processing time significantly, which is hardly achievable using a single method. Third, to enhance eye-detection accuracy, eye validation is applied after initial eye detection, using a support vector machine based on appearance features obtained by principal component analysis (PCA) and linear discriminant analysis (LDA). Fourth, we propose a novel eye state-detection algorithm that combines appearance features obtained using PCA and LDA, with statistical features such as the sparseness and kurtosis of the histogram from the horizontal edge image of the eye. Experimental results showed that the detection accuracies of the eye region and eye states were 99 and 97%, respectively. Both driver drowsiness and distraction were detected with a success rate of 98%.
Uchino, Miki; Kawazoe, Takashi; Kamiyashiki, Masaaki; Sano, Kokoro; Tsubota, Kazuo
2013-01-01
Background A Web-based self-check system including a brief questionnaire would seem to be a suitable tool for rapid disease screening. Objective The purpose of this preliminary study was to test a Web-based self-screening questionnaire for drawing attention to dry eye disease among general Internet users and identifying those with a higher risk of developing the condition. Methods A survey website was launched and used to recruit participants from general Internet users. In the first phase, volunteers were asked to complete a Web-based self-screening questionnaire containing 12 questions on dry eye symptoms. The second phase focused on the respondents who reported five or more dry eye symptoms and expressed their intention to seek medical attention. These participants performed the Schirmer test, for evaluating tear production, and completed a paper-based lifestyle questionnaire to provide relevant background data. Results Of the 1689 visitors to the website, 980 (58.0%) volunteers completed the Web-based self-screening questionnaire. Among these, 355 (36.2%) respondents reported five or more dry eye symptoms. Then, 99 (27.9%) of the symptomatic participants performed the Schirmer test and completed the paper-based lifestyle questionnaire. Out of these, 32 (32.2%) had abnormal tear production (≤5 mm). Conclusions The proposed Web-based self-screening questionnaire seems to be a promising tool for raising awareness of dry eye disease among general Internet users and identifying those with a higher risk of developing the condition, although further research is needed to validate its effectiveness. PMID:24072379
Intraocular lens design for treating high myopia based on individual eye model
NASA Astrophysics Data System (ADS)
Wang, Yang; Wang, Zhaoqi; Wang, Yan; Zuo, Tong
2007-02-01
In this research, we firstly design the phakic intraocular lens (PIOL) based on individual eye model with optical design software ZEMAX. The individual PIOL is designed to correct the defocus and astigmatism, and then we compare the PIOL power calculated from the individual eye model with that from the experiential formula. Close values of PIOL power are obtained between the individual eye model and the formula, but the suggested method has more accuracy with more functions. The impact of PIOL decentration on human eye is evaluated, including rotation decentration, flat axis decentration, steep axis decentration and axial movement of PIOL, which is impossible with traditional method. To control the PIOL decentration errors, we give the limit values of PIOL decentration for the specific eye in this study.
Parker, Andrew; Parkin, Adam; Dagnall, Neil
2013-01-01
Performing a sequence of fast saccadic horizontal eye movements has been shown to facilitate performance on a range of cognitive tasks, including the retrieval of episodic memories. One explanation for these effects is based on the hypothesis that saccadic eye movements increase hemispheric interaction, and that such interactions are important for particular types of memory. The aim of the current research was to assess the effect of horizontal saccadic eye movements on the retrieval of both episodic autobiographical memory (event/incident based memory) and semantic autobiographical memory (fact based memory) over recent and more distant time periods. It was found that saccadic eye movements facilitated the retrieval of episodic autobiographical memories (over all time periods) but not semantic autobiographical memories. In addition, eye movements did not enhance the retrieval of non-autobiographical semantic memory. This finding illustrates a dissociation between the episodic and semantic characteristics of personal memory and is considered within the context of hemispheric contributions to episodic memory performance.
Effects of Saccadic Bilateral Eye Movements on Episodic and Semantic Autobiographical Memory Fluency
Parker, Andrew; Parkin, Adam; Dagnall, Neil
2013-01-01
Performing a sequence of fast saccadic horizontal eye movements has been shown to facilitate performance on a range of cognitive tasks, including the retrieval of episodic memories. One explanation for these effects is based on the hypothesis that saccadic eye movements increase hemispheric interaction, and that such interactions are important for particular types of memory. The aim of the current research was to assess the effect of horizontal saccadic eye movements on the retrieval of both episodic autobiographical memory (event/incident based memory) and semantic autobiographical memory (fact based memory) over recent and more distant time periods. It was found that saccadic eye movements facilitated the retrieval of episodic autobiographical memories (over all time periods) but not semantic autobiographical memories. In addition, eye movements did not enhance the retrieval of non-autobiographical semantic memory. This finding illustrates a dissociation between the episodic and semantic characteristics of personal memory and is considered within the context of hemispheric contributions to episodic memory performance. PMID:24133435
NASA Astrophysics Data System (ADS)
Elleuch, Hanene; Wali, Ali; Samet, Anis; Alimi, Adel M.
2017-03-01
Two systems of eyes and hand gestures recognition are used to control mobile devices. Based on a real-time video streaming captured from the device's camera, the first system recognizes the motion of user's eyes and the second one detects the static hand gestures. To avoid any confusion between natural and intentional movements we developed a system to fuse the decision coming from eyes and hands gesture recognition systems. The phase of fusion was based on decision tree approach. We conducted a study on 5 volunteers and the results that our system is robust and competitive.
Postoperative refraction in the second eye having cataract surgery.
Leffler, Christopher T; Wilkes, Martin; Reeves, Juliana; Mahmood, Muneera A
2011-01-01
Introduction. Previous cataract surgery studies assumed that first-eye predicted and observed postoperative refractions are equally important for predicting second-eye postoperative refraction. Methods. In a retrospective analysis of 173 patients having bilateral sequential phacoemulsification, multivariable linear regression was used to predict the second-eye postoperative refraction based on refractions predicted by the SRK-T formula for both eyes, the first-eye postoperative refraction, and the difference in IOL selected between eyes. Results. The first-eye observed postoperative refraction was an independent predictor of the second eye postoperative refraction (P < 0.001) and was weighted more heavily than the first-eye predicted refraction. Compared with the SRK-T formula, this model reduced the root-mean-squared (RMS) error of the predicted refraction by 11.3%. Conclusions. The first-eye postoperative refraction is an independent predictor of the second-eye postoperative refraction. The first-eye predicted refraction is less important. These findings may be due to interocular symmetry.
Proposed new classification scheme for chemical injury to the human eye.
Bagley, Daniel M; Casterton, Phillip L; Dressler, William E; Edelhauser, Henry F; Kruszewski, Francis H; McCulley, James P; Nussenblatt, Robert B; Osborne, Rosemarie; Rothenstein, Arthur; Stitzel, Katherine A; Thomas, Karluss; Ward, Sherry L
2006-07-01
Various ocular alkali burn classification schemes have been published and used to grade human chemical eye injuries for the purpose of identifying treatments and forecasting outcomes. The ILSI chemical eye injury classification scheme was developed for the additional purpose of collecting detailed human eye injury data to provide information on the mechanisms associated with chemical eye injuries. This information will have clinical application, as well as use in the development and validation of new methods to assess ocular toxicity. A panel of ophthalmic researchers proposed the new classification scheme based upon current knowledge of the mechanisms of eye injury, and their collective clinical and research experience. Additional ophthalmologists and researchers were surveyed to critique the scheme. The draft scheme was revised, and the proposed scheme represents the best consensus from at least 23 physicians and scientists. The new scheme classifies chemical eye injury into five categories based on clinical signs, symptoms, and expected outcomes. Diagnostic classification is based primarily on two clinical endpoints: (1) the extent (area) of injury at the limbus, and (2) the degree of injury (area and depth) to the cornea. The new classification scheme provides a uniform system for scoring eye injury across chemical classes, and provides enough detail for the clinician to collect data that will be relevant to identifying the mechanisms of ocular injury.
Image-based computer-assisted diagnosis system for benign paroxysmal positional vertigo
NASA Astrophysics Data System (ADS)
Kohigashi, Satoru; Nakamae, Koji; Fujioka, Hiromu
2005-04-01
We develop the image based computer assisted diagnosis system for benign paroxysmal positional vertigo (BPPV) that consists of the balance control system simulator, the 3D eye movement simulator, and the extraction method of nystagmus response directly from an eye movement image sequence. In the system, the causes and conditions of BPPV are estimated by searching the database for record matching with the nystagmus response for the observed eye image sequence of the patient with BPPV. The database includes the nystagmus responses for simulated eye movement sequences. The eye movement velocity is obtained by using the balance control system simulator that allows us to simulate BPPV under various conditions such as canalithiasis, cupulolithiasis, number of otoconia, otoconium size, and so on. Then the eye movement image sequence is displayed on the CRT by the 3D eye movement simulator. The nystagmus responses are extracted from the image sequence by the proposed method and are stored in the database. In order to enhance the diagnosis accuracy, the nystagmus response for a newly simulated sequence is matched with that for the observed sequence. From the matched simulation conditions, the causes and conditions of BPPV are estimated. We apply our image based computer assisted diagnosis system to two real eye movement image sequences for patients with BPPV to show its validity.
Eye vs. Text Movement: Which Technique Leads to Faster Reading Comprehension?
ERIC Educational Resources Information Center
Abdellah, Antar Solhy
2009-01-01
Eye fixation is a frequent problem that faces foreign language learners and hinders the flow of their reading comprehension. Although students are usually advised to read fast/skim to overcome this problem, eye fixation persists. The present study investigates the effect of using a paper-based program as compared to a computer-based software in…
Survey of Ophthalmologists Regarding Practice Patterns for Dry Eye and Sjogren Syndrome.
Bunya, Vatinee Y; Fernandez, Karen B; Ying, Gui-Shuang; Massaro-Giordano, Mina; Macchi, Ilaria; Sulewski, Michael E; Hammersmith, Kristin M; Nagra, Parveen K; Rapuano, Christopher J; Orlin, Stephen E
2018-01-15
To survey ophthalmologists about current practice patterns regarding the evaluation of dry eye patients and referrals for a Sjogren syndrome (SS) workup. An online survey was sent to ophthalmologists affiliated with the Scheie Eye Institute or Wills Eye Hospital using REDCap in August 2015. Descriptive statistics were used to summarize the data. Four hundred seventy-four survey invitations were sent out and 101 (21%) ophthalmologists completed the survey. The common traditional dry eye test performed was corneal fluorescein staining (62%) and the most common newer dry eye test performed was tear osmolarity (18%). Half of respondents (51%) refer fewer than 5% of their dry eye patients for SS workups, with 18% reporting that they never refer any patients. The most common reasons for referrals included positive review of systems (60%), severe dry eye symptoms (51%) or ocular signs (47%), or dry eye that is refractory to treatment (42%). The majority (83%) felt that there is a need for an evidence-based standardized screening tool for dry eye patients to decide who should be referred for evaluation for SS. Ophthalmologists continue to prefer the use of traditional dry eye tests in practice, with the most common test being corneal fluorescein staining. There is an underreferral of dry eye patients for SS workups, which is contributing to the continued underdiagnosis of the disease. Most respondents felt that there was a need for an evidence-based standardized screening tool to decide which dry eye patients should be referred for SS evaluations.
Reivitis, Alex; Karimi, Kian; Griffiths, Chester; Banayan, Ashley
2018-04-16
Topical treatments containing tripeptide and hexapeptide (TriHex technology) have been proven to contribute to youthful skin by clearing the extracellular matrix and stimulating collagen and elastin production. Evaluate the efficacy of a novel eye treatment containing TriHex peptides and other synergistic ingredients for the daily treatment of fine lines/crow's feet around the eyes, under eye hollowing, under eye bags, and dark circles. In this study, 10 subjects (9 female and 1 male) aged 30-60 of Fitzpatrick skin type I, II, or III were selected to use an eye treatment containing TriHex peptides and active botanicals (Alastin Restorative Eye Treatment with TriHex Technology™, ALASTIN Skincare, Inc., Carlsbad, CA) twice daily for 12 weeks. Subjects were photographed and evaluated at baseline, week 4, week 8, and week 12 by a board-certified facial plastic surgeon. Using an adjusted Griffiths scale (0 = none, best possible condition and 9 = severe, worst possible condition), subjects were evaluated on severity of fine lines/crow's feet, under eye hollowing, under eye bags, and dark circles at each visit. Subjects completed a "Subject Questionnaire" at week 4, week 8, and week 12 pertaining to the subject's observations and perceived improvement of these measures. Based on the investigator's assessments, overall improvement in periocular skin was noted for all 10 subjects. Over the course of 12 weeks, raw scores significantly decreased indicating reduction of lines/crow's feet (41% improvement), under eye hollowing (29% improvement), under eye bags (48% improvement), and dark circles (39% improvement). Based on the "Subject Questionnaire," all subjects noted overall improvement of the appearance of skin around the eyes. Based on the findings of this study, this eye treatment containing TriHex peptides and active botanicals is an effective stand-alone treatment for the rejuvenation of periocular skin. When used twice daily, this product can reduce the appearance of lines/crow's feet, under eye hollowing, under eye bags, and dark circles. © 2018 Wiley Periodicals, Inc.
Emergency eye care in rural Australia: role of internet.
Kumar, S; Yogesan, K; Hudson, B; Tay-Kearney, M-L; Constable, I J
2006-12-01
Significant differences exist in the utilization of emergency eye care services in rural and urban Australia. Meanwhile, influence of internet-based technology in emergency eye care service utilization has not been established. This study aims to demonstrate, from a health provider perspective, an internet-based service's impact on emergency eye care in rural Australia. The teleophthalmology service was initiated in the Carnarvon Regional Hospital (CRH) of the Gascoyne region in Western Australia. A digital, slit lamp and fundus camera were used for the service. Economic data was gathered from the Department of Health of Western Australia (DOHWA), the CRH and the Lions Eye Institute. During the study period (January-December, 2003) 118 persons took part in teleophthalmology consultations. Emergency cases constituted 3% of these consultations. Previous year, there were seven eye-related emergency evacuations (inter-hospital air transfers) from the Gascoyne region to City of Perth. Analysis demonstrates implementation of internet-based health services has a marked impact on rural emergency eye care delivery. Internet is well suited to ophthalmology for the diagnosis and management of acute conditions in remote areas. Integration of such services to mainstream health care is recommended.
Payne, Hannah L
2017-01-01
Eye movements provide insights about a wide range of brain functions, from sensorimotor integration to cognition; hence, the measurement of eye movements is an important tool in neuroscience research. We describe a method, based on magnetic sensing, for measuring eye movements in head-fixed and freely moving mice. A small magnet was surgically implanted on the eye, and changes in the magnet angle as the eye rotated were detected by a magnetic field sensor. Systematic testing demonstrated high resolution measurements of eye position of <0.1°. Magnetic eye tracking offers several advantages over the well-established eye coil and video-oculography methods. Most notably, it provides the first method for reliable, high-resolution measurement of eye movements in freely moving mice, revealing increased eye movements and altered binocular coordination compared to head-fixed mice. Overall, magnetic eye tracking provides a lightweight, inexpensive, easily implemented, and high-resolution method suitable for a wide range of applications. PMID:28872455
Zhang, Yi; Yao, Jing; Wang, Xiao-Hua; Zhao, Lin; Wang, Li-Jun; Wang, Jian-Ming; Zhou, Ai-Yi
2016-02-20
To establish the diagnostic criteria for polypoidal choroidal vasculopathy (PCV) based on spectral-domain optical coherence tomography (SD OCT) by evaluating the sensitivity and specificity of SD OCT in differentiating PCV from wet age-related macular degeneration (wAMD). The clinical data were reviewed for 62 patients (63 eyes) with the initial diagnosis of PCV or wAMD between August, 2012 and June, 2016. Twenty-four patients (25 eyes) were diagnosed to have PCV and 38 (38 eyes) had wAMD based on findings by fundus photography, fluorescein angiography (FFA) and indocyanine green angiography (ICGA). Among the 6 features of SD OCT, namely a sharp RPED peak, double-layer sign, multiple RPED, an RPED notch, a hyporeflective lumen representing polyps, and hyperreflective intraretinal hard exudates, findings of the first two features and at least one of the other features sufficed the diagnosis of PCV; in the absence of the first two features, the diagnosis of PCV was also made when at least 3 of the other features were present simultaneously. The sensitivity and specificity of SD OCT-based diagnosis were estimated by comparison with the gold standard ICGA-based diagnosis. In the 25 eyes with an established diagnosis of PCV, 23 eyes (92.0%) met the diagnostic criteria based on SD OCT findings; in the 38 eyes with the diagnosis of wAMD, only 4 eyes (10.5%) met the criteria. The sensitivity and specificity of SD OCT-based diagnosis of PCV was 92.0% and 89.5%, respectively. s We established the diagnostic criteria for PCV based on SD OCT findings with a high sensitivity and specificity. SD OCT shows a strong capacity for differentiating PCV from wAMD.
Lee, Jun-Hak; Lim, Jeong-Hwan; Hwang, Han-Jeong; Im, Chang-Hwan
2013-01-01
The main goal of this study was to develop a hybrid mental spelling system combining a steady-state visual evoked potential (SSVEP)-based brain-computer interface (BCI) technology and a webcam-based eye-tracker, which utilizes information from the brain electrical activity and eye gaze direction at the same time. In the hybrid mental spelling system, a character decoded using SSVEP was not typed if the position of the selected character was not matched with the eye direction information ('left' or 'right') obtained from the eye-tracker. Thus, the users did not need to correct a misspelled character using a 'BACKSPACE' key. To verify the feasibility of the developed hybrid mental spelling system, we conducted online experiments with ten healthy participants. Each participant was asked to type 15 English words consisting of 68 characters. As a result, 16.6 typing errors could be prevented on average, demonstrating that the implemented hybrid mental spelling system could enhance the practicality of our mental spelling system.
Effects of Bilateral Eye Movements on Gist Based False Recognition in the DRM Paradigm
ERIC Educational Resources Information Center
Parker, Andrew; Dagnall, Neil
2007-01-01
The effects of saccadic bilateral (horizontal) eye movements on gist based false recognition was investigated. Following exposure to lists of words related to a critical but non-studied word participants were asked to engage in 30s of bilateral vs. vertical vs. no eye movements. Subsequent testing of recognition memory revealed that those who…
ERIC Educational Resources Information Center
Yang, Fang-Ying; Tsai, Meng-Jung; Chiou, Guo-Li; Lee, Silvia Wen-Yu; Chang, Cheng-Chieh; Chen, Li-Ling
2018-01-01
The main purpose of this study was to provide instructional suggestions for supporting science learning in digital environments based on a review of eye tracking studies in e-learning related areas. Thirty-three eye-tracking studies from 2005 to 2014 were selected from the Social Science Citation Index (SSCI) database for review. Through a…
Computational Model-Based Prediction of Human Episodic Memory Performance Based on Eye Movements
NASA Astrophysics Data System (ADS)
Sato, Naoyuki; Yamaguchi, Yoko
Subjects' episodic memory performance is not simply reflected by eye movements. We use a ‘theta phase coding’ model of the hippocampus to predict subjects' memory performance from their eye movements. Results demonstrate the ability of the model to predict subjects' memory performance. These studies provide a novel approach to computational modeling in the human-machine interface.
Evaluation of Eye Metrics as a Detector of Fatigue
2010-03-01
eyeglass frames . The cameras are angled upward toward the eyes and extract real-time pupil diameter, eye-lid movement, and eye-ball movement. The...because the cameras were mounted on eyeglass -like frames , the system was able to continuously monitor the eye throughout all sessions. Overall, the...of “ fitness for duty” testing and “real-time monitoring” of operator performance has been slow (Institute of Medicine, 2004). Oculometric-based
Driver fatigue detection based on eye state.
Lin, Lizong; Huang, Chao; Ni, Xiaopeng; Wang, Jiawen; Zhang, Hao; Li, Xiao; Qian, Zhiqin
2015-01-01
Nowadays, more and more traffic accidents occur because of driver fatigue. In order to reduce and prevent it, in this study, a calculation method using PERCLOS (percentage of eye closure time) parameter characteristics based on machine vision was developed. It determined whether a driver's eyes were in a fatigue state according to the PERCLOS value. The overall workflow solutions included face detection and tracking, detection and location of the human eye, human eye tracking, eye state recognition, and driver fatigue testing. The key aspects of the detection system incorporated the detection and location of human eyes and driver fatigue testing. The simplified method of measuring the PERCLOS value of the driver was to calculate the ratio of the eyes being open and closed with the total number of frames for a given period. If the eyes were closed more than the set threshold in the total number of frames, the system would alert the driver. Through many experiments, it was shown that besides the simple detection algorithm, the rapid computing speed, and the high detection and recognition accuracies of the system, the system was demonstrated to be in accord with the real-time requirements of a driver fatigue detection system.
NEIBank: Genomics and bioinformatics resources for vision research
Peterson, Katherine; Gao, James; Buchoff, Patee; Jaworski, Cynthia; Bowes-Rickman, Catherine; Ebright, Jessica N.; Hauser, Michael A.; Hoover, David
2008-01-01
NEIBank is an integrated resource for genomics and bioinformatics in vision research. It includes expressed sequence tag (EST) data and sequence-verified cDNA clones for multiple eye tissues of several species, web-based access to human eye-specific SAGE data through EyeSAGE, and comprehensive, annotated databases of known human eye disease genes and candidate disease gene loci. All expression- and disease-related data are integrated in EyeBrowse, an eye-centric genome browser. NEIBank provides a comprehensive overview of current knowledge of the transcriptional repertoires of eye tissues and their relation to pathology. PMID:18648525
[Electronic Device for Retinal and Iris Imaging].
Drahanský, M; Kolář, R; Mňuk, T
This paper describes design and construction of a new device for automatic capturing of eye retina and iris. This device has two possible ways of utilization - either for biometric purposes (persons recognition on the base of their eye characteristics) or for medical purposes as supporting diagnostic device. eye retina, eye iris, device, acquisition, image.
Depth-estimation-enabled compound eyes
NASA Astrophysics Data System (ADS)
Lee, Woong-Bi; Lee, Heung-No
2018-04-01
Most animals that have compound eyes determine object distances by using monocular cues, especially motion parallax. In artificial compound eye imaging systems inspired by natural compound eyes, object depths are typically estimated by measuring optic flow; however, this requires mechanical movement of the compound eyes or additional acquisition time. In this paper, we propose a method for estimating object depths in a monocular compound eye imaging system based on the computational compound eye (COMPU-EYE) framework. In the COMPU-EYE system, acceptance angles are considerably larger than interommatidial angles, causing overlap between the ommatidial receptive fields. In the proposed depth estimation technique, the disparities between these receptive fields are used to determine object distances. We demonstrate that the proposed depth estimation technique can estimate the distances of multiple objects.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Via, Riccardo, E-mail: riccardo.via@polimi.it; Fassi, Aurora; Fattori, Giovanni
Purpose: External beam radiotherapy currently represents an important therapeutic strategy for the treatment of intraocular tumors. Accurate target localization and efficient compensation of involuntary eye movements are crucial to avoid deviations in dose distribution with respect to the treatment plan. This paper describes an eye tracking system (ETS) based on noninvasive infrared video imaging. The system was designed for capturing the tridimensional (3D) ocular motion and provides an on-line estimation of intraocular lesions position based on a priori knowledge coming from volumetric imaging. Methods: Eye tracking is performed by localizing cornea and pupil centers on stereo images captured by twomore » calibrated video cameras, exploiting eye reflections produced by infrared illumination. Additionally, torsional eye movements are detected by template matching in the iris region of eye images. This information allows estimating the 3D position and orientation of the eye by means of an eye local reference system. By combining ETS measurements with volumetric imaging for treatment planning [computed tomography (CT) and magnetic resonance (MR)], one is able to map the position of the lesion to be treated in local eye coordinates, thus enabling real-time tumor referencing during treatment setup and irradiation. Experimental tests on an eye phantom and seven healthy subjects were performed to assess ETS tracking accuracy. Results: Measurements on phantom showed an overall median accuracy within 0.16 mm and 0.40° for translations and rotations, respectively. Torsional movements were affected by 0.28° median uncertainty. On healthy subjects, the gaze direction error ranged between 0.19° and 0.82° at a median working distance of 29 cm. The median processing time of the eye tracking algorithm was 18.60 ms, thus allowing eye monitoring up to 50 Hz. Conclusions: A noninvasive ETS prototype was designed to perform real-time target localization and eye movement monitoring during ocular radiotherapy treatments. The device aims at improving state-of-the-art invasive procedures based on surgical implantation of radiopaque clips and repeated acquisition of X-ray images, with expected positive effects on treatment quality and patient outcome.« less
Via, Riccardo; Fassi, Aurora; Fattori, Giovanni; Fontana, Giulia; Pella, Andrea; Tagaste, Barbara; Riboldi, Marco; Ciocca, Mario; Orecchia, Roberto; Baroni, Guido
2015-05-01
External beam radiotherapy currently represents an important therapeutic strategy for the treatment of intraocular tumors. Accurate target localization and efficient compensation of involuntary eye movements are crucial to avoid deviations in dose distribution with respect to the treatment plan. This paper describes an eye tracking system (ETS) based on noninvasive infrared video imaging. The system was designed for capturing the tridimensional (3D) ocular motion and provides an on-line estimation of intraocular lesions position based on a priori knowledge coming from volumetric imaging. Eye tracking is performed by localizing cornea and pupil centers on stereo images captured by two calibrated video cameras, exploiting eye reflections produced by infrared illumination. Additionally, torsional eye movements are detected by template matching in the iris region of eye images. This information allows estimating the 3D position and orientation of the eye by means of an eye local reference system. By combining ETS measurements with volumetric imaging for treatment planning [computed tomography (CT) and magnetic resonance (MR)], one is able to map the position of the lesion to be treated in local eye coordinates, thus enabling real-time tumor referencing during treatment setup and irradiation. Experimental tests on an eye phantom and seven healthy subjects were performed to assess ETS tracking accuracy. Measurements on phantom showed an overall median accuracy within 0.16 mm and 0.40° for translations and rotations, respectively. Torsional movements were affected by 0.28° median uncertainty. On healthy subjects, the gaze direction error ranged between 0.19° and 0.82° at a median working distance of 29 cm. The median processing time of the eye tracking algorithm was 18.60 ms, thus allowing eye monitoring up to 50 Hz. A noninvasive ETS prototype was designed to perform real-time target localization and eye movement monitoring during ocular radiotherapy treatments. The device aims at improving state-of-the-art invasive procedures based on surgical implantation of radiopaque clips and repeated acquisition of X-ray images, with expected positive effects on treatment quality and patient outcome.
Singh, Tarkeshwar; Perry, Christopher M; Herter, Troy M
2016-01-26
Robotic and virtual-reality systems offer tremendous potential for improving assessment and rehabilitation of neurological disorders affecting the upper extremity. A key feature of these systems is that visual stimuli are often presented within the same workspace as the hands (i.e., peripersonal space). Integrating video-based remote eye tracking with robotic and virtual-reality systems can provide an additional tool for investigating how cognitive processes influence visuomotor learning and rehabilitation of the upper extremity. However, remote eye tracking systems typically compute ocular kinematics by assuming eye movements are made in a plane with constant depth (e.g. frontal plane). When visual stimuli are presented at variable depths (e.g. transverse plane), eye movements have a vergence component that may influence reliable detection of gaze events (fixations, smooth pursuits and saccades). To our knowledge, there are no available methods to classify gaze events in the transverse plane for monocular remote eye tracking systems. Here we present a geometrical method to compute ocular kinematics from a monocular remote eye tracking system when visual stimuli are presented in the transverse plane. We then use the obtained kinematics to compute velocity-based thresholds that allow us to accurately identify onsets and offsets of fixations, saccades and smooth pursuits. Finally, we validate our algorithm by comparing the gaze events computed by the algorithm with those obtained from the eye-tracking software and manual digitization. Within the transverse plane, our algorithm reliably differentiates saccades from fixations (static visual stimuli) and smooth pursuits from saccades and fixations when visual stimuli are dynamic. The proposed methods provide advancements for examining eye movements in robotic and virtual-reality systems. Our methods can also be used with other video-based or tablet-based systems in which eye movements are performed in a peripersonal plane with variable depth.
Postoperative Refraction in the Second Eye Having Cataract Surgery
Leffler, Christopher T.; Wilkes, Martin; Reeves, Juliana; Mahmood, Muneera A.
2011-01-01
Introduction. Previous cataract surgery studies assumed that first-eye predicted and observed postoperative refractions are equally important for predicting second-eye postoperative refraction. Methods. In a retrospective analysis of 173 patients having bilateral sequential phacoemulsification, multivariable linear regression was used to predict the second-eye postoperative refraction based on refractions predicted by the SRK-T formula for both eyes, the first-eye postoperative refraction, and the difference in IOL selected between eyes. Results. The first-eye observed postoperative refraction was an independent predictor of the second eye postoperative refraction (P < 0.001) and was weighted more heavily than the first-eye predicted refraction. Compared with the SRK-T formula, this model reduced the root-mean-squared (RMS) error of the predicted refraction by 11.3%. Conclusions. The first-eye postoperative refraction is an independent predictor of the second-eye postoperative refraction. The first-eye predicted refraction is less important. These findings may be due to interocular symmetry. PMID:24533181
Objective Methods to Test Visual Dysfunction in the Presence of Cognitive Impairment
2015-12-01
the eye and 3) purposeful eye movements to track targets that are resolved. Major Findings: Three major objective tests of vision were successfully...developed and optimized to detect disease. These were 1) the pupil light reflex (either comparing the two eyes or independently evaluating each eye ...separately for retina or optic nerve damage, 2) eye movement based analysis of target acquisition, fixation, and eccentric viewing as a means of
Design of integrated eye tracker-display device for head mounted systems
NASA Astrophysics Data System (ADS)
David, Y.; Apter, B.; Thirer, N.; Baal-Zedaka, I.; Efron, U.
2009-08-01
We propose an Eye Tracker/Display system, based on a novel, dual function device termed ETD, which allows sharing the optical paths of the Eye tracker and the display and on-chip processing. The proposed ETD design is based on a CMOS chip combining a Liquid-Crystal-on-Silicon (LCoS) micro-display technology with near infrared (NIR) Active Pixel Sensor imager. The ET operation allows capturing the Near IR (NIR) light, back-reflected from the eye's retina. The retinal image is then used for the detection of the current direction of eye's gaze. The design of the eye tracking imager is based on the "deep p-well" pixel technology, providing low crosstalk while shielding the active pixel circuitry, which serves the imaging and the display drivers, from the photo charges generated in the substrate. The use of the ETD in the HMD Design enables a very compact design suitable for Smart Goggle applications. A preliminary optical, electronic and digital design of the goggle and its associated ETD chip and digital control, are presented.
Kuchenbecker, J; Blum, M; Paul, F
2016-03-01
In acute unilateral optic neuritis (ON) color vision defects combined with a decrease in visual acuity and contrast sensitivity frequently occur. This study investigated whether a web-based color vision test is a reliable detector of acquired color vision defects in ON and, if so, which charts are particularly suitable. In 12 patients with acute unilateral ON, a web-based color vision test ( www.farbsehtest.de ) with 25 color plates (16 Velhagen/Broschmann and 9 Ishihara color plates) was performed. For each patient the affected eye was tested first and then the unaffected eye. The mean best-corrected distance visual acuity (BCDVA) in the ON eye was 0.36 ± 0.20 and 1.0 ± 0.1 in the contralateral eye. The number of incorrectly read plates correlated with the visual acuity. For the ON eye a total of 134 plates were correctly identified and 166 plates were incorrectly identified, while for the disease-free fellow eye, 276 plates were correctly identified and 24 plates were incorrectly identified. Both of the blue/yellow plates were identified correctly 14 times and incorrectly 10 times using the ON eye and exclusively correctly (24 times) using the fellow eye. The Velhagen/Broschmann plates were incorrectly identified significantly more frequently in comparison with the Ishihara plates. In 4 out of 16 Velhagen/Broschmann plates and 5 out of 9 Ishihara plates, no statistically significant differences between the ON eye and the fellow eye could be detected. The number of incorrectly identified plates correlated with a decrease in visual acuity. Red/green and blue/yellow plates were incorrectly identified significantly more frequently with the ON eye, while the Velhagen/Broschmann color plates were incorrectly identified significantly more frequently than the Ishihara color plates. Thus, under defined test conditions the web-based color vision test can also be used to detect acquired color vision defects, such as those caused by ON. Optimization of the test by altering the combination of plates may be a useful next step.
... affected, resulting in an inadequate tear film and dry eyes. People with extreme eye dryness can develop foamy ... keratomalacia is based on the presence of a dry or ulcerated cornea in an undernourished person. ... eye drops or ointments Treatment of vitamin A deficiency ...
Baghaie, Ahmadreza; Yu, Zeyun; D'Souza, Roshan M
2017-04-01
In this paper, we review state-of-the-art techniques to correct eye motion artifacts in Optical Coherence Tomography (OCT) imaging. The methods for eye motion artifact reduction can be categorized into two major classes: (1) hardware-based techniques and (2) software-based techniques. In the first class, additional hardware is mounted onto the OCT scanner to gather information about the eye motion patterns during OCT data acquisition. This information is later processed and applied to the OCT data for creating an anatomically correct representation of the retina, either in an offline or online manner. In software based techniques, the motion patterns are approximated either by comparing the acquired data to a reference image, or by considering some prior assumptions about the nature of the eye motion. Careful investigations done on the most common methods in the field provides invaluable insight regarding future directions of the research in this area. The challenge in hardware-based techniques lies in the implementation aspects of particular devices. However, the results of these techniques are superior to those obtained from software-based techniques because they are capable of capturing secondary data related to eye motion during OCT acquisition. Software-based techniques on the other hand, achieve moderate success and their performance is highly dependent on the quality of the OCT data in terms of the amount of motion artifacts contained in them. However, they are still relevant to the field since they are the sole class of techniques with the ability to be applied to legacy data acquired using systems that do not have extra hardware to track eye motion. Copyright © 2017 Elsevier B.V. All rights reserved.
A Novel Hybrid Mental Spelling Application Based on Eye Tracking and SSVEP-Based BCI
Stawicki, Piotr; Gembler, Felix; Rezeika, Aya; Volosyak, Ivan
2017-01-01
Steady state visual evoked potentials (SSVEPs)-based Brain-Computer interfaces (BCIs), as well as eyetracking devices, provide a pathway for re-establishing communication for people with severe disabilities. We fused these control techniques into a novel eyetracking/SSVEP hybrid system, which utilizes eye tracking for initial rough selection and the SSVEP technology for fine target activation. Based on our previous studies, only four stimuli were used for the SSVEP aspect, granting sufficient control for most BCI users. As Eye tracking data is not used for activation of letters, false positives due to inappropriate dwell times are avoided. This novel approach combines the high speed of eye tracking systems and the high classification accuracies of low target SSVEP-based BCIs, leading to an optimal combination of both methods. We evaluated accuracy and speed of the proposed hybrid system with a 30-target spelling application implementing all three control approaches (pure eye tracking, SSVEP and the hybrid system) with 32 participants. Although the highest information transfer rates (ITRs) were achieved with pure eye tracking, a considerable amount of subjects was not able to gain sufficient control over the stand-alone eye-tracking device or the pure SSVEP system (78.13% and 75% of the participants reached reliable control, respectively). In this respect, the proposed hybrid was most universal (over 90% of users achieved reliable control), and outperformed the pure SSVEP system in terms of speed and user friendliness. The presented hybrid system might offer communication to a wider range of users in comparison to the standard techniques. PMID:28379187
Ali, S M; Reisner, L A; King, B; Cao, A; Auner, G; Klein, M; Pandya, A K
2008-01-01
A redesigned motion control system for the medical robot Aesop allows automating and programming its movements. An IR eye tracking system has been integrated with this control interface to implement an intelligent, autonomous eye gaze-based laparoscopic positioning system. A laparoscopic camera held by Aesop can be moved based on the data from the eye tracking interface to keep the user's gaze point region at the center of a video feedback monitor. This system setup provides autonomous camera control that works around the surgeon, providing an optimal robotic camera platform.
Impact of Glaucoma and Dry Eye on Text-Based Searching.
Sun, Michelle J; Rubin, Gary S; Akpek, Esen K; Ramulu, Pradeep Y
2017-06-01
We determine if visual field loss from glaucoma and/or measures of dry eye severity are associated with difficulty searching, as judged by slower search times on a text-based search task. Glaucoma patients with bilateral visual field (VF) loss, patients with clinically significant dry eye, and normally-sighted controls were enrolled from the Wilmer Eye Institute clinics. Subjects searched three Yellow Pages excerpts for a specific phone number, and search time was recorded. A total of 50 glaucoma subjects, 40 dry eye subjects, and 45 controls completed study procedures. On average, glaucoma patients exhibited 57% longer search times compared to controls (95% confidence interval [CI], 26%-96%, P < 0.001), and longer search times were noted among subjects with greater VF loss ( P < 0.001), worse contrast sensitivity ( P < 0.001), and worse visual acuity ( P = 0.026). Dry eye subjects demonstrated similar search times compared to controls, though worse Ocular Surface Disease Index (OSDI) vision-related subscores were associated with longer search times ( P < 0.01). Search times showed no association with OSDI symptom subscores ( P = 0.20) or objective measures of dry eye ( P > 0.08 for Schirmer's testing without anesthesia, corneal fluorescein staining, and tear film breakup time). Text-based visual search is slower for glaucoma patients with greater levels of VF loss and dry eye patients with greater self-reported visual difficulty, and these difficulties may contribute to decreased quality of life in these groups. Visual search is impaired in glaucoma and dry eye groups compared to controls, highlighting the need for compensatory strategies and tools to assist individuals in overcoming their deficiencies.
Lee, Hankil; Jang, Yong Jung; Lee, Hyung Keun; Kang, Hye Young
2017-12-01
Age-related eye disease is often considered part of natural aging. Lack of awareness of eye conditions can result in missed treatment. We investigated the rates of awareness of cataract and age-related macular degeneration, the most common age-related eye-diseases, and the associated factors among elderly Koreans. We identified 7,403 study subjects (≥40 years old) with cataract or age-related macular degeneration based on ophthalmic examination results during the 5th Korean National Health and Nutrition Examination Survey conducted between 2010 and 2012. We assessed whether patients were aware of their eye condition based on a previous diagnosis by a physician. The average awareness rate over the 3-year study period was 23.69% in subjects with cataract and 1.45% in subjects with age-related macular degeneration. Logistic regression analysis showed that patients with cataract were more likely to recognize their condition if they had myopia (odds ratio, 2.08), hyperopia (odds ratio, 1.33), family history of eye disease (odds ratio, 1.44), or a past eye examination (odds ratio, 4.07-29.10). The presence of diabetes mellitus was also a significant predictor of patient awareness of cataract (odds ratio, 1.88). Poor patient recognition of eye disease among the Korean elderly highlights the seriousness of this potential public health problem in our aging society. Pre-existing eye-related conditions and diabetes were significant predictors of awareness; therefore, patients in frequent contact with their doctors have a greater chance of detecting eye disease. © 2017 The Korean Ophthalmological Society
NASA Astrophysics Data System (ADS)
Komogortsev, Oleg V.; Karpov, Alexey; Holland, Corey D.
2012-06-01
The widespread use of computers throughout modern society introduces the necessity for usable and counterfeit-resistant authentication methods to ensure secure access to personal resources such as bank accounts, e-mail, and social media. Current authentication methods require tedious memorization of lengthy pass phrases, are often prone to shouldersurfing, and may be easily replicated (either by counterfeiting parts of the human body or by guessing an authentication token based on readily available information). This paper describes preliminary work toward a counterfeit-resistant usable eye movement-based (CUE) authentication method. CUE does not require any passwords (improving the memorability aspect of the authentication system), and aims to provide high resistance to spoofing and shoulder-surfing by employing the combined biometric capabilities of two behavioral biometric traits: 1) oculomotor plant characteristics (OPC) which represent the internal, non-visible, anatomical structure of the eye; 2) complex eye movement patterns (CEM) which represent the strategies employed by the brain to guide visual attention. Both OPC and CEM are extracted from the eye movement signal provided by an eye tracking system. Preliminary results indicate that the fusion of OPC and CEM traits is capable of providing a 30% reduction in authentication error when compared to the authentication accuracy of individual traits.
ERIC Educational Resources Information Center
Spichtig, Alexandra N.; Hiebert, Elfrieda H.; Vorstius, Christian; Pascoe, Jeffrey P.; Pearson, P. David; Radach, Ralph
2016-01-01
The present study measured the comprehension-based silent reading efficiency of U.S. students in grades 2, 4, 6, 8, 10, and 12. Students read standardized grade-level passages while an eye movement recording system was used to measure reading rate, fixations (eye stops) per word, fixation durations, and regressions (right-to-left eye movements)…
Dose verification of eye plaque brachytherapy using spectroscopic dosimetry.
Jarema, T; Cutajar, D; Weaver, M; Petasecca, M; Lerch, M; Kejda, A; Rosenfeld, A
2016-09-01
Eye plaque brachytherapy has been developed and refined for the last 80 years, demonstrating effective results in the treatment of ocular malignancies. Current dosimetry techniques for eye plaque brachytherapy (such as TLD- and film-based techniques) are time consuming and cannot be used prior to treatment in a sterile environment. The measurement of the expected dose distribution within the eye, prior to insertion within the clinical setting, would be advantageous, as any errors in source loading will lead to an erroneous dose distribution and inferior treatment outcomes. This study investigated the use of spectroscopic dosimetry techniques for real-time quality assurance of I-125 based eye plaques, immediately prior to insertion. A silicon detector based probe, operating in spectroscopy mode was constructed, containing a small (1 mm(3)) silicon detector, mounted within a ceramic holder, all encapsulated within a rubber sheath to prevent water infiltration of the electronics. Preliminary tests of the prototype demonstrated that the depth dose distribution through the central axis of an I-125 based eye plaque may be determined from AAPM Task Group 43 recommendations to a deviation of 6 % at 3 mm depth, 7 % at 5 mm depth, 1 % at 10 mm depth and 13 % at 20 mm depth, with the deviations attributed to the construction of the probe. A new probe design aims to reduce these discrepancies, however the concept of spectroscopic dosimetry shows great promise for use in eye plaque quality assurance in the clinical setting.
SU-E-I-37: Eye Lens Dose Reduction From CT Scan Using Organ Based Tube Current Modulation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, H; Rensselaer Polytechnic Inst., Troy, NY; Liu, T
Purpose: To investigate the eye lens dose reduction by CT scan with organ based tube current modulation (OBTCM) using GPU Monte Carlo code ARCHER-CT. Methods: 36 X-ray sources and bowtie filters were placed around the patient head with the projection angle interval of 10° for one rotation of CT scan, each projection was simulated respectively. The voxel eye models with high resolution(0.1mm*0.1mm*0.1mm) were used in the simulation and different tube voltage including 80kVp, 100kVp, 120kVp and 140kVp were taken into consideration. Results: The radiation doses to the eye lens increased with the tube voltage raised from 80kVp to 140kVp, andmore » the dose results from 0° (AP) direction are much higher than those from 180° (PA) direction for all the 4 different tube voltage investigated. This 360° projection dose characteristic enables organ based TCM, which can reduce the eye lens dose by more than 55%. Conclusion: As the eye lens belongs to superficial tissues, its radiation dose to external exposure like CT is direction sensitive, and this characteristic feature makes organ based TCM to be an effective way to reduce the eye lens dose, so more clinical use of this technique were recommended. National Nature Science Foundation of China(No.11475047)« less
2010-01-01
Background European robins, Erithacus rubecula, show two types of directional responses to the magnetic field: (1) compass orientation that is based on radical pair processes and lateralized in favor of the right eye and (2) so-called 'fixed direction' responses that originate in the magnetite-based receptors in the upper beak. Both responses are light-dependent. Lateralization of the 'fixed direction' responses would suggest an interaction between the two magnetoreception systems. Results Robins were tested with either the right or the left eye covered or with both eyes uncovered for their orientation under different light conditions. With 502 nm turquoise light, the birds showed normal compass orientation, whereas they displayed an easterly 'fixed direction' response under a combination of 502 nm turquoise with 590 nm yellow light. Monocularly right-eyed birds with their left eye covered were oriented just as they were binocularly as controls: under turquoise in their northerly migratory direction, under turquoise-and-yellow towards east. The response of monocularly left-eyed birds differed: under turquoise light, they were disoriented, reflecting a lateralization of the magnetic compass system in favor of the right eye, whereas they continued to head eastward under turquoise-and-yellow light. Conclusion 'Fixed direction' responses are not lateralized. Hence the interactions between the magnetite-receptors in the beak and the visual system do not seem to involve the magnetoreception system based on radical pair processes, but rather other, non-lateralized components of the visual system. PMID:20707905
Dry Eye Treatment Based on Contact Lens Drug Delivery: A Review.
Guzman-Aranguez, Ana; Fonseca, Begoña; Carracedo, Gonzalo; Martin-Gil, Alba; Martinez-Aguila, Alejandro; Pintor, Jesús
2016-09-01
Dry eye disease affects a substantial segment of the word population with increasing frequency. It is a multifactorial disease of the ocular surface and tear film, which causes ocular discomfort, visual disturbances, and tear instability with potential damage to the cornea and conjunctiva. Because of its multifactorial etiology, the use of different pharmacological treatment for dry eye treatment has been proposed, which include anti-inflammatory molecules, lubricants or comfort agents, and secretagogues. However, in some cases these pharmacological approaches only relieve symptoms temporarily, and consequently, eye care professionals continue to have difficulties managing dry eye. To improve pharmacological therapy that allows a more efficient and long-term action, effective ocular drug delivery of the currently available drugs for dry eye treatment is required. Contact lenses are emerging as alternative ophthalmic drugs delivery systems that provide an increased residence time of the drug at the eye, thus leading to enhanced bioavailability and more convenient and efficacious therapy. In this article, we reviewed the different techniques used to prepare contact lens-based drug delivery systems and focused on articles that describe the delivery of compounds for dry eye treatment through contact lenses.
Schuster, Alexander K; Pick, Julia; Saalmann, Frauke; Pfeiffer, Norbert
2018-04-10
Eye diseases causing visual impairment increase with age. Thus, seeking eye care has a higher probability in older people. In this study, the rate of utilization of outpatient eye care services in Germany was analyzed. The analyses focused on older persons and persons in need of either home-based or facility-based long-term care. A descriptive secondary data analysis of health insurance data of the AOK Baden-Württemberg from 2016 was conducted. The study population comprised all insured persons on 1 January 2016. The cohort of older persons (60 years+) was further stratified by the type of care (home-based/facility-based) and the level of care (0-3). The utilization of outpatient eye care services was defined by the reimbursement for an ophthalmologist's provision of service. While 39.3% of the study population 60+ years old sought eye care, the utilization rate was lower among people in need of home-based (33.0%) and facility-based care (19.3%). The utilization rates showed comparable age-dependent patterns, except for persons in need of facility-based care where rates were similar for all age groups. Utilization rates were negatively associated with increasing care levels. Only people with care level 0 showed lower utilization rates than people with care level 1. Utilization rates of eye healthcare services among older persons are considerably influenced by the need of long-term care, by the form of care as well as by the level of care.
Retinal Detachment in Southwest Ethiopia: A Hospital Based Prospective Study
Asaminew, Tsedeke; Gelaw, Yeshigeta; Bekele, Sisay; Solomon, Berhan
2013-01-01
Purpose The incidence of retinal detachment in Blacks is generally considered to be low though there are few supporting studies in Africa. This study, thus, aimed at describing the clinical profile of patients with retinal detachment in Southwest Ethiopia. Methods A hospital-based study was done on all consecutive retinal detachment patients who presented to Jimma University Hospital over six months period. A semi-structured questionnaire was used to collect patients’ sociodemographic characteristics and clinical history. Comprehensive anterior and posterior segment eye examinations were done and risk factors were sought for. Statistical tests were considered significant if P < 0.05. Results A total of 94 eyes of 80 patients (1.5%) had retinal detachment (RD) and about 69% of patients were symptomatic for over a month before presentation. The mean age was 41.4 years (SD ±16.5). Fourteen patients (17.5%) had bilateral RD. At presentation, 61 eyes (64.9%) were blind from RD and 11 (13.8%) patients were bilaterally blind from RD. Rhegmatogenous RD was seen in 55 eyes (58.5%) and tractional RD in 22 eyes (23.4%). The most common risk factors were ocular trauma (32 eyes, 34.0%), myopia (23 eyes, 24.5%), posterior uveitis (13 eyes, 13.8%) and diabetic retinopathy (9 eyes, 9.6%). Most retinal breaks (25 eyes, 43.1%) were superotemporal and horse-shoe tear was the most common (19 eyes, 20.2%). Macula was off in 77 eyes (81.9%) and 38 eyes (69.1% of RRD eyes) had grade C proliferative vitreoretinopathy (PVR). Macular status was significantly associated with PVR (P=0.011), and duration of symptoms (RR=1.25, 95%CI: 1.059-1.475, P=0.040). Conclusions A significant numbers of patients with ocular problem had retinal detachment, and nearly two third of the patients presented late. Trauma and myopia were the most important risk factors. People should be educated to improve their health seeking behavior and use eye safety precautions to prevent ocular trauma. PMID:24086614
Registration of Panoramic/Fish-Eye Image Sequence and LiDAR Points Using Skyline Features
Zhu, Ningning; Jia, Yonghong; Ji, Shunping
2018-01-01
We propose utilizing a rigorous registration model and a skyline-based method for automatic registration of LiDAR points and a sequence of panoramic/fish-eye images in a mobile mapping system (MMS). This method can automatically optimize original registration parameters and avoid the use of manual interventions in control point-based registration methods. First, the rigorous registration model between the LiDAR points and the panoramic/fish-eye image was built. Second, skyline pixels from panoramic/fish-eye images and skyline points from the MMS’s LiDAR points were extracted, relying on the difference in the pixel values and the registration model, respectively. Third, a brute force optimization method was used to search for optimal matching parameters between skyline pixels and skyline points. In the experiments, the original registration method and the control point registration method were used to compare the accuracy of our method with a sequence of panoramic/fish-eye images. The result showed: (1) the panoramic/fish-eye image registration model is effective and can achieve high-precision registration of the image and the MMS’s LiDAR points; (2) the skyline-based registration method can automatically optimize the initial attitude parameters, realizing a high-precision registration of a panoramic/fish-eye image and the MMS’s LiDAR points; and (3) the attitude correction values of the sequences of panoramic/fish-eye images are different, and the values must be solved one by one. PMID:29883431
Vienola, Kari V; Damodaran, Mathi; Braaf, Boy; Vermeer, Koenraad A; de Boer, Johannes F
2018-02-01
Retinal motion detection with an accuracy of 0.77 arcmin corresponding to 3.7 µm on the retina is demonstrated with a novel digital micromirror device based ophthalmoscope. By generating a confocal image as a reference, eye motion could be measured from consecutively measured subsampled frames. The subsampled frames provide 7.7 millisecond snapshots of the retina without motion artifacts between the image points of the subsampled frame, distributed over the full field of view. An ophthalmoscope pattern projection speed of 130 Hz enabled a motion detection bandwidth of 65 Hz. A model eye with a scanning mirror was built to test the performance of the motion detection algorithm. Furthermore, an in vivo motion trace was obtained from a healthy volunteer. The obtained eye motion trace clearly shows the three main types of fixational eye movements. Lastly, the obtained eye motion trace was used to correct for the eye motion in consecutively obtained subsampled frames to produce an averaged confocal image correct for motion artefacts.
Vienola, Kari V.; Damodaran, Mathi; Braaf, Boy; Vermeer, Koenraad A.; de Boer, Johannes F.
2018-01-01
Retinal motion detection with an accuracy of 0.77 arcmin corresponding to 3.7 µm on the retina is demonstrated with a novel digital micromirror device based ophthalmoscope. By generating a confocal image as a reference, eye motion could be measured from consecutively measured subsampled frames. The subsampled frames provide 7.7 millisecond snapshots of the retina without motion artifacts between the image points of the subsampled frame, distributed over the full field of view. An ophthalmoscope pattern projection speed of 130 Hz enabled a motion detection bandwidth of 65 Hz. A model eye with a scanning mirror was built to test the performance of the motion detection algorithm. Furthermore, an in vivo motion trace was obtained from a healthy volunteer. The obtained eye motion trace clearly shows the three main types of fixational eye movements. Lastly, the obtained eye motion trace was used to correct for the eye motion in consecutively obtained subsampled frames to produce an averaged confocal image correct for motion artefacts. PMID:29552396
iDEAS: A web-based system for dry eye assessment.
Remeseiro, Beatriz; Barreira, Noelia; García-Resúa, Carlos; Lira, Madalena; Giráldez, María J; Yebra-Pimentel, Eva; Penedo, Manuel G
2016-07-01
Dry eye disease is a public health problem, whose multifactorial etiology challenges clinicians and researchers making necessary the collaboration between different experts and centers. The evaluation of the interference patterns observed in the tear film lipid layer is a common clinical test used for dry eye diagnosis. However, it is a time-consuming task with a high degree of intra- as well as inter-observer variability, which makes the use of a computer-based analysis system highly desirable. This work introduces iDEAS (Dry Eye Assessment System), a web-based application to support dry eye diagnosis. iDEAS provides a framework for eye care experts to collaboratively work using image-based services in a distributed environment. It is composed of three main components: the web client for user interaction, the web application server for request processing, and the service module for image analysis. Specifically, this manuscript presents two automatic services: tear film classification, which classifies an image into one interference pattern; and tear film map, which illustrates the distribution of the patterns over the entire tear film. iDEAS has been evaluated by specialists from different institutions to test its performance. Both services have been evaluated in terms of a set of performance metrics using the annotations of different experts. Note that the processing time of both services has been also measured for efficiency purposes. iDEAS is a web-based application which provides a fast, reliable environment for dry eye assessment. The system allows practitioners to share images, clinical information and automatic assessments between remote computers. Additionally, it save time for experts, diminish the inter-expert variability and can be used in both clinical and research settings. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Zhang, Shuqing; Zhou, Luyang; Xue, Changxi; Wang, Lei
2017-09-10
Compound eyes offer a promising field of miniaturized imaging systems. In one application of a compound eye, superposition of compound eye systems forms a composite image by superposing the images produced by different channels. The geometric configuration of superposition compound eye systems is achieved by three micro-lens arrays with different pitches and focal lengths. High resolution is indispensable for the practicability of superposition compound eye systems. In this paper, hybrid diffractive-refractive lenses are introduced into the design of a compound eye system for this purpose. With the help of ZEMAX, two superposition compound eye systems with and without hybrid diffractive-refractive lenses were separately designed. Then, we demonstrate the effectiveness of using a hybrid diffractive-refractive lens to improve the image quality.
ECEM (Eye Closure, Eye Movements): application to depersonalization disorder.
Harriet, E Hollander
2009-10-01
Eye Closure, Eye Movements (ECEM) is a hypnotically-based approach to treatment that incorporates eye movements adapted from the Eye Movement Desensitization and Reprocessing (EMDR) protocol in conjunction with hypnosis for the treatment of depersonalization disorder. Depersonalization Disorder has been differentiated from post-traumatic stress disorders and has recently been conceptualized as a subtype of panic disorder (Baker et al., 2003; David, Phillips, Medford, & Sierra, 2004; Segui et. al., 2000). During ECEM, while remaining in a hypnotic state, clients self-generated six to seven trials of eye movements to reduce anticipatory anxiety associated with depersonalization disorder. Eye movements were also used to process triggers that elicited breath holding, often followed by episodes of depersonalization. Hypnotic suggestions were used to reverse core symptoms of depersonalization, subjectively described as "feeling unreal" (Simeon et al., 1997).
Effect of lipid-based dry eye supplements on the tear film in wearers of eye cosmetics.
Wang, Michael T M; Cho, Irene Sung Hee; Jung, Soo Hee; Craig, Jennifer P
2017-08-01
To compare the effects on tear film parameters and contamination in cosmetic eyeliner wearers, after single application of two lipid-based dry eye treatments: a lipid-containing lubricant eye drop and a phospholipid liposomal spray. Fifty participants were enrolled in a prospective, randomised, paired-eye, investigator-masked trial. Pencil eyeliner (Body Shop ® Crayon Eye Definer) was applied to the upper eyelid periocular skin of both eyes, anterior to the lash line. Baseline tear film quality was assessed fifteen minutes after eyeliner application. A lubricant drop (Systane ® Balance) was then applied to one eye (randomised), and liposomal spray (Tears Again ® ) to the contralateral eye. Tear film contamination, lipid layer grade, non-invasive tear film break-up time and tear evaporation rate were evaluated fifteen minutes post-treatment and compared to pre-treatment values. Pre-treatment measurements did not differ between eyes assigned to lubricant drop and liposomal spray. Tear film contamination was observed in a greater proportion of eyes following both treatments (both p<0.05), with no significant difference between treatments (p=0.41). Both treatments improved lipid layer thickness (both p≤0.01), but effected no significant change in non-invasive tear film break-up time or tear evaporation rate (all p>0.05). Changes in tear film parameters did not differ between treatments (all p>0.05). Both the lipid-containing lubricant eye drop and phospholipid liposomal spray result in clinically apparent tear film contamination in eyeliner cosmetic wearers. Although both treatments effected an increase in lipid layer thickness, neither displayed clinical efficacy in improving tear film stability. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Use of EyeCam for imaging the anterior chamber angle.
Perera, Shamira A; Baskaran, Mani; Friedman, David S; Tun, Tin A; Htoon, Hla M; Kumar, Rajesh S; Aung, Tin
2010-06-01
To compare EyeCam (Clarity Medical Systems, Pleasanton, CA) imaging with gonioscopy for detecting angle closure. In this prospective, hospital-based study, subjects underwent gonioscopy by a single observer and EyeCam imaging by a different operator. EyeCam images were graded by two masked observers. The anterior chamber angle in a quadrant was classified as closed if the trabecular meshwork could not be seen. The eye was classified as having angle closure if two or more quadrants were closed. One hundred fifty-two subjects were studied. The mean age was 57.4 years (SD 12.9) and there were 82 (54%) men. Of the 152 eyes, 21 (13.8%) had angle closure. The EyeCam provided clear images of the angles in 98.8% of subjects. The agreement between the EyeCam and gonioscopy for detecting angle closure in the superior, inferior, nasal, and temporal quadrants based on agreement coefficient (AC1) statistics was 0.73, 0.75, 0.76, and 0.72, respectively. EyeCam detected more closed angles than did gonioscopy in all quadrants (P < 0.05). With gonioscopy, 21/152 (13.8%) eyes were diagnosed as angle closure compared to 41 (27.0%) of 152 with EyeCam (P < 0.001, McNemar Test), giving an overall sensitivity of 76.2% (95% confidence interval [CI], 54.9%-90.7%), specificity of 80.9% (95%CI, 73.5%-87.3%), and an area under the receiver operating characteristic curve (AUC) of 0.79. The EyeCam showed good agreement with gonioscopy for detecting angle closure. However, it detected more closed angles than did gonioscopy in all quadrants.
A field evaluation of the Eye-Closure Interview with witnesses of serious crimes.
Vredeveldt, Annelies; Tredoux, Colin G; Nortje, Alicia; Kempen, Kate; Puljević, Cheneal; Labuschagne, Gérard N
2015-04-01
Laboratory research shows that eye-closure during memory retrieval improves both the amount and the factual accuracy of memory reports about witnessed events. Based on these findings, we developed the Eye-Closure Interview, and examined its feasibility (in terms of compliance with the instructions) and effectiveness (in terms of the quantity and quality of reported information) in eyewitness interviews conducted by the South African Police Service. Police interviewers from the Facial Identification Unit were randomly assigned to receive Eye-Closure Interview training or no training. We analyzed 95 interviews with witnesses of serious crimes (including robbery, rape, and murder), some of whom were instructed to close their eyes during salient parts of the interview. Witnesses in the control condition rarely spontaneously closed their eyes, but witnesses in the Eye-Closure Interview condition kept their eyes closed during 97% of their descriptions, suggesting that the Eye-Closure Interview would be easy to implement in a field setting. Although witnesses who closed their eyes did not remember more information overall, the information they provided was considered to be of significantly greater forensic relevance (as reflected in 2 independent blind assessments, 1 by a senior police expert and 1 by a senior researcher). Thus, based on the findings from this field study and from previous laboratory research, we conclude that implementation of the Eye-Closure Interview in witness interviews would help police interviewers to elicit more valuable information from witnesses, which could be relevant to the police investigation and/or in court. (PsycINFO Database Record (c) 2015 APA, all rights reserved).
Treatment of Sjögren's syndrome-associated dry eye an evidence-based review.
Akpek, Esen Karamursel; Lindsley, Kristina B; Adyanthaya, Rohit S; Swamy, Ramya; Baer, Alan N; McDonnell, Peter J
2011-07-01
Outcomes-based review of reported treatment options for patients with dry eye secondary to Sjögren's syndrome (SS). Dry eye affects many individuals worldwide. Significant proportion of patients with dry eye has underlying SS, a progressive autoimmune condition. The few suggested guidelines for the treatment of dry eye are mostly based on severity of symptoms and/or clinical findings rather than on outcomes analysis, and do not differentiate SS from other causes of dry eye. METHODS AND LITERATURE REVIEW: A search strategy was developed to identify prospective, interventional studies of treatments for SS-associated dry eye from electronic databases. Eligible references were restricted to English-language articles published after 1975. These sources were augmented by hand searches of reference lists from accessed articles. Study selection, data extraction, and grading of evidence were completed independently by ≥4 review authors. The searches identified 3559 references as of August 10, 2010. After duplicate review of the titles and abstracts, 245 full-text papers were assessed, 62 of which were relevant for inclusion in the review. In the current literature on SS-associated dry eye, there is a paucity of rigorous clinical trials to support therapy recommendations. Nonetheless, the recommended treatments include topical lubricants, topical anti-inflammatory therapy, and tear-conserving strategies. The efficacy of oral secretagogues seems greater in the treatment of oral dryness than ocular dryness. Although oral hydroxychloroquine is commonly prescribed to patients with SS to alleviate fatigue and arthralgias, the literature lacks strong evidence for the efficacy of this treatment for dry eye. Copyright © 2011 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Impact of Glaucoma and Dry Eye on Text-Based Searching
Sun, Michelle J.; Rubin, Gary S.; Akpek, Esen K.; Ramulu, Pradeep Y.
2017-01-01
Purpose We determine if visual field loss from glaucoma and/or measures of dry eye severity are associated with difficulty searching, as judged by slower search times on a text-based search task. Methods Glaucoma patients with bilateral visual field (VF) loss, patients with clinically significant dry eye, and normally-sighted controls were enrolled from the Wilmer Eye Institute clinics. Subjects searched three Yellow Pages excerpts for a specific phone number, and search time was recorded. Results A total of 50 glaucoma subjects, 40 dry eye subjects, and 45 controls completed study procedures. On average, glaucoma patients exhibited 57% longer search times compared to controls (95% confidence interval [CI], 26%–96%, P < 0.001), and longer search times were noted among subjects with greater VF loss (P < 0.001), worse contrast sensitivity (P < 0.001), and worse visual acuity (P = 0.026). Dry eye subjects demonstrated similar search times compared to controls, though worse Ocular Surface Disease Index (OSDI) vision-related subscores were associated with longer search times (P < 0.01). Search times showed no association with OSDI symptom subscores (P = 0.20) or objective measures of dry eye (P > 0.08 for Schirmer's testing without anesthesia, corneal fluorescein staining, and tear film breakup time). Conclusions Text-based visual search is slower for glaucoma patients with greater levels of VF loss and dry eye patients with greater self-reported visual difficulty, and these difficulties may contribute to decreased quality of life in these groups. Translational Relevance Visual search is impaired in glaucoma and dry eye groups compared to controls, highlighting the need for compensatory strategies and tools to assist individuals in overcoming their deficiencies. PMID:28670502
Exercise program improved subjective dry eye symptoms for office workers.
Sano, Kokoro; Kawashima, Motoko; Takechi, Sayuri; Mimura, Masaru; Tsubota, Kazuo
2018-01-01
We investigated the benefits of a cognitive behavior therapy-based exercise program to reduce the dry eye symptoms of office workers. We recruited 11 office workers with dry eye symptoms, aged 31-64 years, who voluntarily participated in group health guidance at a manufacturing company. Participants learned about the role of physical activity and exercise in enhancing wellness and performed an exercise program at home 3 days per week for 10 weeks. We estimated the indexes of body composition, dry eye symptoms, and psychological distress using the Dry Eye-Related Quality of Life Score and the World Health Organization's Subjective Well-Being Inventory questionnaires pre- and postintervention. The 10-week exercise program and the questionnaires were completed by 48.1% (39 of 81) of the participants. Body composition did not change pre- and postintervention. However, the average of the Dry Eye-Related Quality of Life Score scores in participants with subjective dry eye significantly improved after the intervention. Moreover, the World Health Organization's Subjective Well-Being Inventory positive well-being score tended to increase after the intervention. In this study, we showed that a 10-week exercise program improved subjective dry eye symptoms of healthy office workers. Our study suggests that a cognitive behavior therapy-based exercise program can play an important role in the treatment of patients with dry eye disease.
New methods for the assessment of accommodative convergence.
Asakawa, Ken; Ishikawa, Hitoshi; Shoji, Nobuyuki
2009-01-01
The authors introduced a new objective method for measuring horizontal eye movements based on the first Purkinje image with the use of infrared charge-coupled device (CCD) cameras and compared stimulus accommodative convergence to accommodation (AC/A) ratios as determined by a standard gradient method. The study included 20 patients, 5 to 9 years old, who had intermittent exotropia (10 eyes) and accommodative esotropia (10 eyes). Measurement of horizontal eye movements in millimeters (mm), based on the first Purkinje image, was obtained with a TriIRIS C9000 instrument (Hamamatsu Photonics K.K., Hamamatsu, Japan). The stimulus AC/A ratio was determined with the far gradient method. The average values of horizontal eye movements (mm) and eye deviation (Delta) (a) before and (b) after an accommodative stimulus of 3.00 diopters (D) were calculated with the following formula: horizontal eye movements (mm/D) and stimulus AC/A ratio (Delta/D) = (b - a)/3. The average values of the horizontal eye movements and the stimulus AC/A ratio were 0.5 mm/D and 3.8 Delta/D, respectively. Correlation analysis showed a strong positive correlation between these two parameters (r = 0.92). Moreover, horizontal eye movements are directly proportional to the AC/A ratio measured with the gradient method. The methods used in this study allow objective recordings of accommodative convergence to be obtained in many clinical situations. Copyright 2009, SLACK Incorporated.
NASA Astrophysics Data System (ADS)
Maguen, Ezra I.; Salz, James J.; McDonald, Marguerite B.; Pettit, George H.; Papaioannou, Thanassis; Grundfest, Warren S.
2002-06-01
A study was undertaken to assess whether results of laser vision correction with the LADARVISION 193-nm excimer laser (Alcon-Autonomous technologies) can be improved with the use of wavefront analysis generated by a proprietary system including a Hartman-Schack sensor and expressed using Zernicke polynomials. A total of 82 eyes underwent LASIK in several centers with an improved algorithm, using the CustomCornea system. A subgroup of 48 eyes of 24 patients was randomized so that one eye undergoes conventional treatment and one eye undergoes treatment based on wavefront analysis. Treatment parameters were equal for each type of refractive error. 83% of all eyes had uncorrected vision of 20/20 or better and 95% were 20/25 or better. In all groups, uncorrected visual acuities did not improve significantly in eyes treated with wavefront analysis compared to conventional treatments. Higher order aberrations were consistently better corrected in eyes undergoing treatment based on wavefront analysis for LASIK at 6 months postop. In addition, the number of eyes with reduced RMS was significantly higher in the subset of eyes treated with a wavefront algorithm (38% vs. 5%). Wavefront technology may improve the outcomes of laser vision correction with the LADARVISION excimer laser. Further refinements of the technology and clinical trials will contribute to this goal.
Arora, Karun S; Boland, Michael V; Friedman, David S; Jefferys, Joan L; West, Sheila K; Ramulu, Pradeep Y
2013-12-01
To determine the extent of difference between better-eye visual field (VF) mean deviation (MD) and integrated VF (IVF) MD among Salisbury Eye Evaluation (SEE) subjects and a larger group of glaucoma clinic subjects and to assess how those measures relate to objective and subjective measures of ability/performance in SEE subjects. Retrospective analysis of population- and clinic-based samples of adults. A total of 490 SEE and 7053 glaucoma clinic subjects with VF loss (MD ≤-3 decibels [dB] in at least 1 eye). Visual field testing was performed in each eye, and IVF MD was calculated. Differences between better-eye and IVF MD were calculated for SEE and clinic-based subjects. In SEE subjects with VF loss, models were constructed to compare the relative impact of better-eye and IVF MD on driving habits, mobility, self-reported vision-related function, and reading speed. Difference between better-eye and IVF MD and relationship of better-eye and IVF MD with performance measures. The median difference between better-eye and IVF MD was 0.41 dB (interquartile range [IQR], -0.21 to 1.04 dB) and 0.72 dB (IQR, 0.04-1.45 dB) for SEE subjects and clinic-based patients with glaucoma, respectively, with differences of ≥ 2 dB between the 2 MDs observed in 9% and 18% of the groups, respectively. Among SEE subjects with VF loss, both MDs demonstrated similar associations with multiple ability and performance metrics as judged by the presence/absence of a statistically significant association between the MD and the metric, the magnitude of observed associations (odds ratios, rate ratios, or regression coefficients associated with 5-dB decrements in MD), and the extent of variability in the metric explained by the model (R(2)). Similar associations of similar magnitude also were noted for the subgroup of subjects with glaucoma and subjects in whom better-eye and IVF MD differed by ≥ 2 dB. The IVF MD rarely differs from better-eye MD, and similar associations between VF loss and visual disability are obtained using either MD. Unlike better-eye MD, IVF measurements require extra software/calculation. As such, information from studies using better-eye MD can be more easily integrated into clinical decision-making, making better-eye MD a robust and meaningful method for reporting VF loss severity. Copyright © 2013 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Real-time driver fatigue detection based on face alignment
NASA Astrophysics Data System (ADS)
Tao, Huanhuan; Zhang, Guiying; Zhao, Yong; Zhou, Yi
2017-07-01
The performance and robustness of fatigue detection largely decrease if the driver with glasses. To address this issue, this paper proposes a practical driver fatigue detection method based on face alignment at 3000 FPS algorithm. Firstly, the eye regions of the driver are localized by exploiting 6 landmarks surrounding each eye. Secondly, the HOG features of the extracted eye regions are calculated and put into SVM classifier to recognize the eye state. Finally, the value of PERCLOS is calculated to determine whether the driver is drowsy or not. An alarm will be generated if the eye is closed for a specified period of time. The accuracy and real-time on testing videos with different drivers demonstrate that the proposed algorithm is robust and obtain better accuracy for driver fatigue detection compared with some previous method.
A panoramic imaging system based on fish-eye lens
NASA Astrophysics Data System (ADS)
Wang, Ye; Hao, Chenyang
2017-10-01
Panoramic imaging has been closely watched as one of the major technologies of AR and VR. Mainstream panoramic imaging techniques lenses include fish-eye lenses, image splicing, and catadioptric imaging system. Meanwhile, fish-eyes are widely used in the big picture video surveillance. The advantage of fish-eye lenses is that they are easy to operate and cost less, but how to solve the image distortion of fish-eye lenses has always been a very important topic. In this paper, the image calibration algorithm of fish-eye lens is studied by comparing the method of interpolation, bilinear interpolation and double three interpolation, which are used to optimize the images.
Toy, Brian C; Myung, David J; He, Lingmin; Pan, Carolyn K; Chang, Robert T; Polkinhorne, Alison; Merrell, Douglas; Foster, Doug; Blumenkranz, Mark S
2016-05-01
To compare clinical assessment of diabetic eye disease by standard dilated examination with data gathered using a smartphone-based store-and-forward teleophthalmology platform. 100 eyes of 50 adult patients with diabetes from a health care safety-net ophthalmology clinic. All patients underwent comprehensive ophthalmic examination. Concurrently, a smartphone was used to estimate near visual acuity and capture anterior and dilated posterior segment photographs, which underwent masked, standardized review. Quantitative comparison of clinic and smartphone-based data using descriptive, kappa, Bland-Altman, and receiver operating characteristic analyses was performed. Smartphone visual acuity was successfully measured in all eyes. Anterior and posterior segment photography was of sufficient quality to grade in 96 and 98 eyes, respectively. There was good correlation between clinical Snellen and smartphone visual acuity measurements (rho = 0.91). Smartphone-acquired fundus photographs demonstrated 91% sensitivity and 99% specificity to detect moderate nonproliferative and worse diabetic retinopathy, with good agreement between clinic and photograph grades (kappa = 0.91 ± 0.1, P < 0.001; AUROC = 0.97, 95% confidence interval, 0.93-1). The authors report a smartphone-based telemedicine system that demonstrated sensitivity and specificity to detect referral-warranted diabetic eye disease as a proof-of-concept. Additional studies are warranted to evaluate this approach to expanding screening for diabetic retinopathy.
NASA Astrophysics Data System (ADS)
Hirtl, Rene; Schmid, Gernot
2013-09-01
A modern wireless intra-ocular pressure monitoring system, based on 13.56 MHz inductively coupled data transmission, was dosimetrically analyzed with respect to the specific absorption rate (SAR) induced inside the head and the eye due to the electromagnetic field exposure caused by the reader antenna of the transmission system. The analysis was based on numerical finite difference time domain computations using a high resolution anatomical eye model integrated in a modern commercially available anatomical model of a male head. Three different reader antenna configurations, a 7-turn elliptic (30 mm × 50 mm) antenna at 12 mm distance from the eye, a flexible circular antenna (60 mm diameter, 8 turns on 2 mm substrate) directly attached to the skin, and a circular 7-turn antenna (30 mm diameter at 12 mm distance to the eye) were analyzed, respectively. Possible influences of the eye-lid status (closed or opened) and the transponder antenna contained in a contact lens directly attached to the eye were taken into account. The results clearly demonstrated that for typical reader antenna currents required for proper data transmission, the SAR values remain far below the limits for localized exposure of the head, as defined by the International Commission for Non-Ionizing Radiation Protection. Particularly the induced SAR inside the eye was found to be substantially (orders of magnitudes for typical reader antenna currents in the order of 1 A turn) below values which have been reported to be critical with respect to thermally induced adverse health effects in eye tissues.
Murakami, Tomoaki; Ueda-Arakawa, Naoko; Nishijima, Kazuaki; Uji, Akihito; Horii, Takahiro; Ogino, Ken; Yoshimura, Nagahisa
2014-03-28
To integrate parameters on spectral-domain optical coherence tomography (SD-OCT) in diabetic retinopathy (DR) based on the self-organizing map and objectively describe the macular morphologic patterns. A total of 336 consecutive eyes of 216 patients with DR for whom clear SD-OCT images were available were retrospectively reviewed. Eleven OCT parameters and the logarithm of the minimal angle of resolution (logMAR) were measured. These multidimensional data were analyzed based on the self-organizing map on which similar cases were near each other according to the degree of their similarities, followed by the objective clustering. Self-organizing maps indicated that eyes with greater retinal thickness in the central subfield had greater thicknesses in the superior and temporal subfields. Eyes with foveal serous retinal detachment (SRD) had greater thickness in the nasal or inferior subfield. Eyes with foveal cystoid spaces were arranged to the left upper corner on the two-dimensional map; eyes with foveal SRD to the left lower corner; eyes with thickened retinal parenchyma to the lower area. The following objective clustering demonstrated the unsupervised pattern recognition of macular morphologies in diabetic macular edema (DME) as well as the higher-resolution discrimination of DME per se. Multiple regression analyses showed better association of logMAR with retinal thickness in the inferior subfield in eyes with SRD and with external limiting membrane disruption in eyes with foveal cystoid spaces or thickened retinal parenchyma. The self-organizing map facilitates integrative understanding of the macular morphologic patterns and the structural/functional relationship in DR.
Simulation of wave propagation inside a human eye: acoustic eye model (AEM)
NASA Astrophysics Data System (ADS)
Požar, T.; Halilovič, M.; Horvat, D.; Petkovšek, R.
2018-02-01
The design and development of the acoustic eye model (AEM) is reported. The model consists of a computer-based simulation that describes the propagation of mechanical disturbance inside a simplified model of a human eye. The capabilities of the model are illustrated with examples, using different laser-induced initial loading conditions in different geometrical configurations typically occurring in ophthalmic medical procedures. The potential of the AEM is to predict the mechanical response of the treated eye tissue in advance, thus complementing other preliminary procedures preceding medical treatments.
Dry Eye Disease and Microbial Keratitis: Is There a Connection?
Narayanan, Srihari; Redfern, Rachel L.; Miller, William L.; Nichols, Kelly K.; McDermott, Alison M.
2013-01-01
Dry eye is a common ocular surface disease of multifactorial etiology characterized by elevated tear osmolality and inflammation leading to a disrupted ocular surface. The latter is a risk factor for ocular surface infection, yet overt infection is not commonly seen clinically in the typical dry eye patient. This suggests that important innate mechanisms operate to protect the dry eye from invading pathogens. This article reviews the current literature on epidemiology of ocular surface infection in dry eye patients and laboratory-based studies on innate immune mechanisms operating at the ocular surface and their alterations in human dry eye and animal models. The review highlights current understanding of innate immunity in dry eye and identifies gaps in our knowledge to help direct future studies to further unravel the complexities of dry eye disease and its sequelae. PMID:23583043
Eye contact as an antecedent to compliant behavior
Hamlet, Carolynn C.; Axelrod, Saul; Kuerschner, Steven
1984-01-01
Many experimenters and practitioners regard eye contact between instructor and learner as a facilitator, if not a prerequisite, to the effective instruction of sighted people. Without scientifically supporting the practice of demanding eye contact, experimenters, nonetheless, advocate its use and offer a variety of procedures to promote its acquisition. To justify the widespread use of demanded eye contact and to explain its role functionally, one experiment and data from six replications with nine subjects are presented. The primary experiment provides an empirical base for the training of eye contact prior to instruction. In a multiple-baseline design across two students demanded eye contact resulted in levels of compliance that were double and triple those of baseline. A tentative functional analysis of demanded eye contact is presented, followed by a discussion of the relationship of eye contact to attending. PMID:16795682
A Clinical Study of Subtype-based Prevalence of Dry Eye.
Rege, Aditya; Kulkarni, Varsha; Puthran, Neelam; Khandgave, Tejaswini
2013-10-01
Dry Eye is a multifactorial disease of the tearfilm and the ocular surface which may be due to reduced tear production or excessive tear evaporation resulting in discomfort, visual disturbance, and tear film instability with a potential damage to the ocular surface. Various population-based studies have been done to find out the prevalence and the magnitude of the problem. Women Health Study reported prevalence of 7.8% after screening 36995 subjects above 49 years by interview. The prevalence reported by Blue Mountain Study was 15.3% .The Beaver Dam Study and Shiphai Eye studies are other studies reporting prevalence of 14.5% and 33.7% respectively. McMonnies questionnaire is a widely used screening instrument for Dry-Eye syndromes with sensitivity reportedly varying between 87% and 98% and specificity between 87% and 97%. Prevalence studies use McMonnie's questionnaire for screening individuals for Dry Eye, whereafter tests like Schirmer's test, Tear Film Break Up Time test, Rose Bengal test, Lissamine Green test and Meibomian Gland Dysfunction test are useful for further evaluation. While these tests help to differentiate the subtypes of Dry Eye such as Lipid Anomaly Dry Eye, Aqueous Tear Deficiency and Mucin Layer Deficiency, however, their sensitivity and specificity has not been widely studied. Additionally, very few studies have reported the prevalence of the various subtypes of Dry Eye. To determine the subtype-based prevalence of Dry Eye, to study the specificity and sensitivity of clinical tests for Dry Eye and to correlate McMonnies questionnaire with Dry Eye tests results. A prospective, cross-sectional, observational study, duly approved by the Institutional Ethics Committee, was conducted from October 2010 to April 2012. A total of 4750 subjects above 18 yrs of age were screened by the McMonnies questionnaire. Respondents having a score greater than 14.5 were subjected to clinical Dry Eye tests. The data obtained was analyzed using chi-square test. p value < 0.005 was considered statistically significant.The specificity and sensitivity of each clinical test was calculated using Schirmer's test as gold standard. The prevalence of Dry Eye was 15.4%, with a female preponderance (p = 0.01) and a significant increase with age above 60 years was noted (p<0.0001). Tear Film Break Up Time was the most reliable test with a good sensitivity (68.85%) and specificity (78.32%). Lipid Anomaly Dry Eye was the most prevalent (14.48%) followed by Aqueous Tear Deficiency (13.36%) and Mucin Layer Deficiency (3.51%). A positive correlation between McMonnies score and severity of Dry Eye was seen. This study suggests that Lipid Layer Anomaly is the most prevalent subtype in Dry Eye. Tear Film Break Up Time test is the most likely test to diagnose mild Dry Eye. McMonies Questionnaire can be effectively used for screening of a large population. Tear Film Break Up Time was found to have better sensitivity as well as specificity than other tests used for diagnosing Dry Eye.
Brain and eyes of Kerygmachela reveal protocerebral ancestry of the panarthropod head.
Park, Tae-Yoon S; Kihm, Ji-Hoon; Woo, Jusun; Park, Changkun; Lee, Won Young; Smith, M Paul; Harper, David A T; Young, Fletcher; Nielsen, Arne T; Vinther, Jakob
2018-03-09
Recent discoveries of fossil nervous tissue in Cambrian fossils have allowed researchers to trace the origin and evolution of the complex arthropod head and brain based on stem groups close to the origin of the clade, rather than on extant, highly derived members. Here we show that Kerygmachela from Sirius Passet, North Greenland, a primitive stem-group euarthropod, exhibits a diminutive (protocerebral) brain that innervates both the eyes and frontal appendages. It has been surmised, based on developmental evidence, that the ancestor of vertebrates and arthropods had a tripartite brain, which is refuted by the fossil evidence presented here. Furthermore, based on the discovery of eyes in Kerygmachela, we suggest that the complex compound eyes in arthropods evolved from simple ocelli, present in onychophorans and tardigrades, rather than through the incorporation of a set of modified limbs.
Maximum entropy perception-action space: a Bayesian model of eye movement selection
NASA Astrophysics Data System (ADS)
Colas, Francis; Bessière, Pierre; Girard, Benoît
2011-03-01
In this article, we investigate the issue of the selection of eye movements in a free-eye Multiple Object Tracking task. We propose a Bayesian model of retinotopic maps with a complex logarithmic mapping. This model is structured in two parts: a representation of the visual scene, and a decision model based on the representation. We compare different decision models based on different features of the representation and we show that taking into account uncertainty helps predict the eye movements of subjects recorded in a psychophysics experiment. Finally, based on experimental data, we postulate that the complex logarithmic mapping has a functional relevance, as the density of objects in this space in more uniform than expected. This may indicate that the representation space and control strategies are such that the object density is of maximum entropy.
Prevalence of Undiagnosed Age-Related Macular Degeneration in Primary Eye Care.
Neely, David C; Bray, Kevin J; Huisingh, Carrie E; Clark, Mark E; McGwin, Gerald; Owsley, Cynthia
2017-06-01
Age-related macular degeneration (AMD) is the leading cause of irreversible vision impairment in older adults in the United States, yet little is known about whether AMD is appropriately diagnosed in primary eye care. To examine the prevalence of eyes with AMD in patients seen in primary eye care clinics who purportedly have normal macular health per their medical record and the association of AMD with patient and physician characteristics. In this cross-sectional study of primary eye care practices in Birmingham, Alabama, 644 persons 60 years or older with normal macular health per medical record based on their most recent dilated comprehensive eye examination by a primary eye care ophthalmologist or optometrist were enrolled from May 1, 2009, through December 31, 2011. Data analysis was performed from May 1, 2016, through December 20, 2016. Presence of AMD as defined by the Clinical Age-Related Maculopathy Staging system based on color fundus photography and a masked grader. Types of AMD-associated lesions were noted. Patient health and physician characteristics were collected. The sample consisted of 1288 eyes from 644 participants (231 [35.9%] male and 413 [64.1%] female; mean [SD] age, 69.4 [6.1] years; 611 white [94.9%]) seen by 31 primary eye care ophthalmologists or optometrists. A total of 968 eyes (75.2%) had no AMD, in agreement with their medical record; 320 (24.8%) had AMD despite no diagnosis of AMD in the medical record. Among eyes with undiagnosed AMD, 32 (10.0%) had hyperpigmentation, 43 (13.4%) had hypopigmentation, 249 (77.8%) had small drusen, 250 (78.1%) had intermediate drusen, and 96 (30.0%) had large drusen. Undiagnosed AMD was associated with older patient age (odds ratio [OR], 1.06; 95% CI, 1.04-1.09; P < .001), male sex (age-adjusted OR, 1.39; 95% CI, 1.02-1.91; P = .04), and less than a high school education (age-adjusted OR, 2.40; 95% CI, 1.03-5.62; P = .04). Prevalence of undiagnosed AMD was not different for ophthalmologists and optometrists (age adjusted OR, 0.99; 95% CI, 0.71-1.36; P = .94). Approximately 25.0% of eyes deemed to be normal based on dilated eye examination by primary eye care physicians had macular characteristics that indicated AMD revealed by fundus photography and trained raters. A total of 30.0% of eyes with undiagnosed AMD had AMD with large drusen that would have been treatable with nutritional supplements had it been diagnosed. Improved AMD detection strategies may be needed in primary eye care as more effective treatment strategies for early AMD become available in the coming years.
Comparison of eye imaging pattern recognition using neural network
NASA Astrophysics Data System (ADS)
Bukhari, W. M.; Syed A., M.; Nasir, M. N. M.; Sulaima, M. F.; Yahaya, M. S.
2015-05-01
The beauty of eye recognition system that it is used in automatic identifying and verifies a human weather from digital images or video source. There are various behaviors of the eye such as the color of the iris, size of pupil and shape of the eye. This study represents the analysis, design and implementation of a system for recognition of eye imaging. All the eye images that had been captured from the webcam in RGB format must through several techniques before it can be input for the pattern and recognition processes. The result shows that the final value of weight and bias after complete training 6 eye images for one subject is memorized by the neural network system and be the reference value of the weight and bias for the testing part. The target classifies to 5 different types for 5 subjects. The eye images can recognize the subject based on the target that had been set earlier during the training process. When the values between new eye image and the eye image in the database are almost equal, it is considered the eye image is matched.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Omar, A; Marteinsdottir, M; Kadesjo, N
Purpose: To provide a general formalism for determination of occupational eye lens dose based on the response of an active personal dosimeter (APD) worn at chest level above the radiation protection apron. Methods: The formalism consists of three factors: (1) APD conversion factor converting the reading at chest level (APDchest) to the corresponding personal dose equivalent at eye level, (2) Dose conversion factor transferring the measured dose quantity, Hp(10), into a dose quantity relevant for the eye lens dose, (3) Correction factor accounting for differences in exposure of the eye(s) compared to the exposure at chest level (e.g., due tomore » protective lead glasses).The different factors were investigated and evaluated based on phantom and clinical measurements performed in an x-ray angiography suite for interventional cardiology. Results: The eye lens dose can be conservatively estimated by assigning an appropriate numerical value to each factor entering the formalism that in most circumstances overestimates the dose. Doing so, the eye lens dose to the primary operator and assisting staff was estimated in this work as D-eye,primary = 2.0 APDchest and D-eye,assisting = 1.0 APDchest, respectively.The annual eye lens dose to three nurses and one cardiologist was estimated to be 2, 2, 2, and 13 mSv (Hp(0.07)), respectively, using a TLD dosimeter worn at eye level. In comparison, using the formalism and APDchest measurements, the respective doses were 2, 2, 2, and 16 mSv (Hp(3)). Conclusion: The formalism outlined in this work can be used to estimate the occupational eye lens dose from the response of an APD worn on the chest. The formalism is general and could be applied also to other types of dosimeters. However, the numerical value of the different factors may differ from those obtained with the APD’s used in this work due to differences in dosimeter properties.« less
Verstraelen, Sandra; Van Rompay, An R
2018-06-01
The main objective of the CON4EI (CONsortium for in vitro Eye Irritation testing strategy) project (2015-2016) was to develop tiered, non-animal testing strategies for serious eye damage and eye irritation assessment in relation to the most important drivers of classification. The serious eye damage and eye irritation potential of a set of 80 chemicals was identified based on existing in vivo Draize eye test data and testing was conducted using the following eight alternative test methods: BCOP (Bovine Corneal Opacity and Permeability)+histopathology, BCOP-LLBO (BCOP Laser Light-Based Opacitometer), ICE (Isolated Chicken Eye)+histopathology, STE (Short Term Exposure), EpiOcular™ EIT (EpiOcular Eye Irritation Test), EpiOcular™ ET-50 (EpiOcular™ Time-to-toxicity), SkinEthic™ HCE EIT (SkinEthic™ Human Corneal Epithelial Eye Irritation Test), and SMI (Slug Mucosal Irritation). Project management decided to not include the ICE data in this project since the execution showed relevant, and not predictable, deviations from Organisation for Economic Co-operation and Development (OECD) Test Guideline (TG) 438 and Guidance Document 160. At this stage, the outcome of these deviations has not been fully assessed. In addition to these alternative test methods, the computational models Toxtree and Case Ultra were taken into account. This project assessed the relevance of these test methods, their applicability domains and limitations in terms of 'drivers of classification', and their strengths and weaknesses. In this way, methods were identified that fit into a tiered-testing strategy for serious eye damage/eye irritation assessment to distinguish United Nations Globally Harmonized System of Classification and Labelling of Chemicals (UN GHS) Category 1 (Cat 1) chemicals from non-Cat 1 chemicals and address the gap namely distinguish between Category 2 (Cat 2) and Cat 1 chemicals. Copyright © 2017 Elsevier Ltd. All rights reserved.
Compressive sensing method for recognizing cat-eye effect targets.
Li, Li; Li, Hui; Dang, Ersheng; Liu, Bo
2013-10-01
This paper proposes a cat-eye effect target recognition method with compressive sensing (CS) and presents a recognition method (sample processing before reconstruction based on compressed sensing, or SPCS) for image processing. In this method, the linear projections of original image sequences are applied to remove dynamic background distractions and extract cat-eye effect targets. Furthermore, the corresponding imaging mechanism for acquiring active and passive image sequences is put forward. This method uses fewer images to recognize cat-eye effect targets, reduces data storage, and translates the traditional target identification, based on original image processing, into measurement vectors processing. The experimental results show that the SPCS method is feasible and superior to the shape-frequency dual criteria method.
A new rhodamine-based colorimetric chemosensor for naked-eye detection of Cu2 + in aqueous solution
NASA Astrophysics Data System (ADS)
Hu, Yang; Zhang, Jing; Lv, Yuan-Zheng; Huang, Xiao-Huan; Hu, Sheng-li
2016-03-01
A new colorimetric probe 1 based on rhodamine B lactam was developed for naked-eye detection of Cu2 +. The optical feature of 1 for Cu2 + was investigated by UV-vis absorption spectroscopy. Upon the addition of Cu2 +, the 1 displayed a distinct color change from colorless to pink, which can be directly detected by the naked eye. The stoichiometry of 1 to Cu2 + complex was found to be 1:1 and the naked-eye detection limit was determined as low as 2 μM. The results suggest that the probe 1 may provide a convenient method for visual detection of Cu2 + with high sensitivity.
ERIC Educational Resources Information Center
Nitschke, Kai; Ruh, Nina; Kappler, Sonja; Stahl, Christoph; Kaller, Christoph P.
2012-01-01
Understanding the functional neuroanatomy of planning and problem solving may substantially benefit from better insight into the chronology of the cognitive processes involved. Based on the assumption that regularities in cognitive processing are reflected in overtly observable eye-movement patterns, here we recorded eye movements while…
Eye movements reflect and shape strategies in fraction comparison.
Ischebeck, Anja; Weilharter, Marina; Körner, Christof
2016-01-01
The comparison of fractions is a difficult task that can often be facilitated by separately comparing components (numerators and denominators) of the fractions--that is, by applying so-called component-based strategies. The usefulness of such strategies depends on the type of fraction pair to be compared. We investigated the temporal organization and the flexibility of strategy deployment in fraction comparison by evaluating sequences of eye movements in 20 young adults. We found that component-based strategies could account for the response times and the overall number of fixations observed for the different fraction pairs. The analysis of eye movement sequences showed that the initial eye movements in a trial were characterized by stereotypical scanning patterns indicative of an exploratory phase that served to establish the kind of fraction pair presented. Eye movements that followed this phase adapted to the particular type of fraction pair and indicated the deployment of specific comparison strategies. These results demonstrate that participants employ eye movements systematically to support strategy use in fraction comparison. Participants showed a remarkable flexibility to adapt to the most efficient strategy on a trial-by-trial basis. Our results confirm the value of eye movement measurements in the exploration of strategic adaptation in complex tasks.
Borgestig, Maria; Sandqvist, Jan; Parsons, Richard; Falkmer, Torbjörn; Hemmingsson, Helena
2016-01-01
Gaze-based assistive technology (gaze-based AT) has the potential to provide children affected by severe physical impairments with opportunities for communication and activities. This study aimed to examine changes in eye gaze performance over time (time on task and accuracy) in children with severe physical impairments, without speaking ability, using gaze-based AT. A longitudinal study with a before and after design was conducted on 10 children (aged 1-15 years) with severe physical impairments, who were beginners to gaze-based AT at baseline. Thereafter, all children used the gaze-based AT in daily activities over the course of the study. Compass computer software was used to measure time on task and accuracy with eye selection of targets on screen, and tests were performed with the children at baseline, after 5 months, 9-11 months, and after 15-20 months. Findings showed that the children improved in time on task after 5 months and became more accurate in selecting targets after 15-20 months. This study indicates that these children with severe physical impairments, who were unable to speak, could improve in eye gaze performance. However, the children needed time to practice on a long-term basis to acquire skills needed to develop fast and accurate eye gaze performance.
Maa, April Y; Wojciechowski, Barbara; Hunt, Kelly J; Dismuke, Clara; Shyu, Jason; Janjua, Rabeea; Lu, Xiaoqin; Medert, Charles M; Lynch, Mary G
2017-04-01
The aging population is at risk of common eye diseases, and routine eye examinations are recommended to prevent visual impairment. Unfortunately, patients are less likely to seek care as they age, which may be the result of significant travel and time burdens associated with going to an eye clinic in person. A new method of eye-care delivery that mitigates distance barriers and improves access was developed to improve screening for potentially blinding conditions. We present the quality data from the early experience (first 13 months) of Technology-Based Eye Care Services (TECS), a novel ophthalmologic telemedicine program. With TECS, a trained ophthalmology technician is stationed in a primary care clinic away from the main hospital. The ophthalmology technician follows a detailed protocol that collects information about the patient's eyes. The information then is interpreted remotely. Patients with possible abnormal findings are scheduled for a face-to-face examination in the eye clinic. Any patient with no known ocular disease who desires a routine eye screening examination is eligible. Technology-Based Eye Care Services was established in 5 primary care clinics in Georgia surrounding the Atlanta Veterans Affairs hospital. Four program operation metrics (patient satisfaction, eyeglass remakes, disease detection, and visit length) and 2 access-to-care metrics (appointment wait time and no-show rate) were tracked. Care was rendered to 2690 patients over the first 13 months of TECS. The program has been met with high patient satisfaction (4.95 of 5). Eyeglass remake rate was 0.59%. Abnormal findings were noted in 36.8% of patients and there was >90% agreement between the TECS reading and the face-to-face findings of the physician. TECS saved both patient (25% less) and physician time (50% less), and access to care substantially improved with 99% of patients seen within 14 days of contacting the eye clinic, with a TECS no-show rate of 5.2%. The early experience with TECS has been promising. Tele-ophthalmology has the potential to improve operational efficiency, reduce cost, and significantly improve access to care. Although further study is necessary, TECS shows potential to help prevent avoidable vision loss. Published by Elsevier Inc.
Toward statistical modeling of saccadic eye-movement and visual saliency.
Sun, Xiaoshuai; Yao, Hongxun; Ji, Rongrong; Liu, Xian-Ming
2014-11-01
In this paper, we present a unified statistical framework for modeling both saccadic eye movements and visual saliency. By analyzing the statistical properties of human eye fixations on natural images, we found that human attention is sparsely distributed and usually deployed to locations with abundant structural information. This observations inspired us to model saccadic behavior and visual saliency based on super-Gaussian component (SGC) analysis. Our model sequentially obtains SGC using projection pursuit, and generates eye movements by selecting the location with maximum SGC response. Besides human saccadic behavior simulation, we also demonstrated our superior effectiveness and robustness over state-of-the-arts by carrying out dense experiments on synthetic patterns and human eye fixation benchmarks. Multiple key issues in saliency modeling research, such as individual differences, the effects of scale and blur, are explored in this paper. Based on extensive qualitative and quantitative experimental results, we show promising potentials of statistical approaches for human behavior research.
Full ocular biometry through dual-depth whole-eye optical coherence tomography
Kim, Hyung-Jin; Kim, Minji; Hyeon, Min Gyu; Choi, Youngwoon; Kim, Beop-Min
2018-01-01
We propose a new method of determining the optical axis (OA), pupillary axis (PA), and visual axis (VA) of the human eye by using dual-depth whole-eye optical coherence tomography (OCT). These axes, as well as the angles “α” between the OA and VA and “κ” between PA and VA, are important in many ophthalmologic applications, especially in refractive surgery. Whole-eye images are reconstructed based on simultaneously acquired images of the anterior segment and retina. The light from a light source is split into two orthogonal polarization components for imaging the anterior segment and retina, respectively. The OA and PA are identified based on their geometric definitions by using the anterior segment image only, while the VA is detected through accurate correlation between the two images. The feasibility of our approach was tested using a model eye and human subjects. PMID:29552378
Research of the aberrations of human eyes with accommodation based on eye model
NASA Astrophysics Data System (ADS)
Quan, Wei; Wang, Feng-lin; Wang, Zhao-qi
2011-06-01
The variation of the wavefront aberration with accommodation was investigated based on the eye model of Gullstrand-Le Grand. The anterior lens radius was optimized at different accommodation to focus the image at the retina, and the RMS and PV wave-front error of human eye were compared at different accommodation. The PV value of wavefront aberration from 0.718 waves increases gradually to 0.904 waves and RMS value from 0.21 waves to 0.26 waves when accommodative stimuli varies from 0 to - 5 diopters. The change of PV value is 0.186 waves which is less than the Rayleigh diffraction limit λ/4, and the change of RMS is 0.05 which under Marechal diffraction limit λ/14. Therefore, the change of the wavefront aberration caused accommodation can be ignored when wavefront aberrations in the human eye are corrected with surgery or wearing glasses.
NASA Astrophysics Data System (ADS)
Xu, Jie; Wang, Xin; Zhan, Qi; Huang, Shengling; Chen, Yifan; Mu, Baozhong
2016-07-01
This paper presents a novel lobster-eye imaging system for X-ray-backscattering inspection. The system was designed by modifying the Schmidt geometry into a treble-lens structure in order to reduce the resolution difference between the vertical and horizontal directions, as indicated by ray-tracing simulations. The lobster-eye X-ray imaging system is capable of operating over a wide range of photon energies up to 100 keV. In addition, the optics of the lobster-eye X-ray imaging system was tested to verify that they meet the requirements. X-ray-backscattering imaging experiments were performed in which T-shaped polymethyl-methacrylate objects were imaged by the lobster-eye X-ray imaging system based on both the double-lens and treble-lens Schmidt objectives. The results show similar resolution of the treble-lens Schmidt objective in both the vertical and horizontal directions. Moreover, imaging experiments were performed using a second treble-lens Schmidt objective with higher resolution. The results show that for a field of view of over 200 mm and with a 500 mm object distance, this lobster-eye X-ray imaging system based on a treble-lens Schmidt objective offers a spatial resolution of approximately 3 mm.
Glaucoma Medication Adherence among African Americans: Program Development
Dreer, Laura E.; Girkin, Christopher A.; Campbell, Lisa; Wood, Andy; Gao, Liyan; Owsley, Cynthia
2014-01-01
Purpose To elucidate barriers and facilitators related to glaucoma medication adherence among African Americans (AA) with glaucoma and to elicit input from a community-based participatory research team in order to guide the development of a culturally informed, health promotion program for improving glaucoma medication adherence among AA’s. Methods The nominal group technique (NGT), a highly structured focus group methodology, was implemented with 12 separate groups of AA’s patients with glaucoma (N = 89) to identify barriers and facilitators related to glaucoma medication usage. Participant rank-ordering votes were summed across groups and categorized into themes. Next, an individually and culturally targeted health promotion program promoting appropriate medication adherence was developed based on focus group results and input from a community-based participatory research team. Results The top five barriers included problems with 1) forgetfulness, 2) side effects, 3) cost/affordability, 4) eye drop administration, and 5) the eye drop schedule. The most salient top five facilitators were 1) fear or thoughts about the consequences of not taking eye drops, 2) use of memory aids, cues, or strategies, 3) maintaining a regular routine or schedule for eye drop administration, 4) ability to afford eye drops, and 5) keeping eye drops in the same area. The resulting health promotion program was based on a multi-component empowerment framework that included glaucoma education, motivational interviewing, and problem-solving training to improve glaucoma medication adherence. Conclusions Barriers and facilitators related to glaucoma medication adherence among AA’s are multifactorial. Based on the NGT themes and input from the community-based participatory research team, a culturally informed, health promotion program was designed and holds great promise for improving medication adherence among this vulnerable population. PMID:23873033
A value-based medicine cost-utility analysis of idiopathic epiretinal membrane surgery.
Gupta, Omesh P; Brown, Gary C; Brown, Melissa M
2008-05-01
To perform a reference case, cost-utility analysis of epiretinal membrane (ERM) surgery using current literature on outcomes and complications. Computer-based, value-based medicine analysis. Decision analyses were performed under two scenarios: ERM surgery in better-seeing eye and ERM surgery in worse-seeing eye. The models applied long-term published data primarily from the Blue Mountains Eye Study and the Beaver Dam Eye Study. Visual acuity and major complications were derived from 25-gauge pars plana vitrectomy studies. Patient-based, time trade-off utility values, Markov modeling, sensitivity analysis, and net present value adjustments were used in the design and calculation of results. Main outcome measures included the number of discounted quality-adjusted-life-years (QALYs) gained and dollars spent per QALY gained. ERM surgery in the better-seeing eye compared with observation resulted in a mean gain of 0.755 discounted QALYs (3% annual rate) per patient treated. This model resulted in $4,680 per QALY for this procedure. When sensitivity analysis was performed, utility values varied from $6,245 to $3,746/QALY gained, medical costs varied from $3,510 to $5,850/QALY gained, and ERM recurrence rate increased to $5,524/QALY. ERM surgery in the worse-seeing eye compared with observation resulted in a mean gain of 0.27 discounted QALYs per patient treated. The $/QALY was $16,146 with a range of $20,183 to $12,110 based on sensitivity analyses. Utility values ranged from $21,520 to $12,916/QALY and ERM recurrence rate increased to $16,846/QALY based on sensitivity analysis. ERM surgery is a very cost-effective procedure when compared with other interventions across medical subspecialties.
Competency based ophthalmology training curriculum for undergraduate medical students in Zimbabwe.
Masanganise, R; Samkange, C; Mukona, D; Aagaard, E
2015-01-01
The establishment of a credible, defensible and acceptable “formal competency based ophthalmology training curriculum for undergraduate medical and dental students” is fundamental to program recognition, monitoring and evaluation. The University of Zimbabwe College of Health Sciences (UZ-CHS) has never had a formal ophthalmology training curriculum for medical graduates since its inception. This has cast doubts on the quality of medical graduates produced with regards to delivery of basic primary eye care in the community. The aim of this project was to develop a formal “competency based ophthalmology training curriculum” (CBOTC) for medical graduates in Zimbabwe. Institution based (University of Zimbabwe College of Health Sciences and Parirenyatwa Group of Hospitals), cross-sectional analytic study. A review of undergraduate medical training curriculum and literature was done to identify gaps in the ophthalmology training curriculum. A local needs assessment was conducted through interviews of major stake holders in the University of Zimbabwe College of Health Sciences and Parirenyatwa Group of Hospitals. This project confirmed the lack of a formal ophthalmology training curriculum for medical graduates at the UZCHS, ad-hoc training of undergraduate ophthalmology and inconsistent student assessment in knowledge of and care of eye complaints. Cataract, glaucoma, refractive errors, ocular tumours, conjunctivitis, eye infection and eye injuries were suggested as priority conditions every student should learn during the rotation. A formal CBOTC for medical graduates based on identified needs and priority eye diseases has been developed in response. A CBOTC based on identified needs and focused on targeted diseases has been proposed geared towards producing medical graduates with the basic knowledge, skills and attitudes to deliver adequate primary eye care.
Structural Neural Substrates of Reading the Mind in the Eyes.
Sato, Wataru; Kochiyama, Takanori; Uono, Shota; Sawada, Reiko; Kubota, Yasutaka; Yoshimura, Sayaka; Toichi, Motomi
2016-01-01
The ability to read the minds of others in their eyes plays an important role in human adaptation to social environments. Behavioral studies have resulted in the development of a test to measure this ability (Reading the Mind in the Eyes Test, revised version; Eyes Test), and have demonstrated that this ability is consistent over time. Although functional neuroimaging studies revealed brain activation while performing the Eyes Test, the structural neural substrates supporting consistent performance on the Eyes Test remain unclear. In this study, we assessed the Eyes Test and analyzed structural magnetic resonance images using voxel-based morphometry (VBM) in healthy participants. Test performance was positively associated with the gray matter volumes of the dorsomedial prefrontal cortex, inferior parietal lobule (temporoparietal junction), and precuneus in the left hemisphere. These results suggest that the fronto-temporoparietal network structures support the consistent ability to read the mind in the eyes.
Development of infrared thermal imager for dry eye diagnosis
NASA Astrophysics Data System (ADS)
Chiang, Huihua Kenny; Chen, Chih Yen; Cheng, Hung You; Chen, Ko-Hua; Chang, David O.
2006-08-01
This study aims at the development of non-contact dry eye diagnosis based on an infrared thermal imager system, which was used to measure the cooling of the ocular surface temperature of normal and dry eye patients. A total of 108 subjects were measured, including 26 normal and 82 dry eye patients. We have observed that the dry eye patients have a fast cooling of the ocular surface temperature than the normal control group. We have developed a simplified algorithm for calculating the temperature decay constant of the ocular surface for discriminating between normal and dry eye. This study shows the diagnostic of dry eye syndrome by the infrared thermal imager system has reached a sensitivity of 79.3%, a specificity of 75%, and the area under the ROC curve 0.841. The infrared thermal imager system has a great potential to be developed for dry eye screening with the advantages of non-contact, fast, and convenient implementation.
A wide angle low coherence interferometry based eye length optometer
NASA Astrophysics Data System (ADS)
Meadway, Alexander; Siegwart, John; Wildsoet, Christine; Norton, Thomas; Zhang, Yuhua
2015-03-01
Interest in eye growth regulation has burgeoned with the rise in myopia prevalence world-wide. Eye length and eye shape are fundamental metrics for related research, but current in vivo measurement techniques are generally limited to the optical axis of the eye. We describe a high resolution, time domain low coherence interferometry based optometer for measuring the eye length of small animals over a wide field of view. The system is based upon a Michelson interferometer using a superluminescent diode as a source, including a sample arm and a reference arm. The sample arm is split into two paths by a polarisation beam splitter; one focuses the light on the cornea and the other focuses the light on the retina. This method has a high efficiency of detection for reflections from both surfaces. The reference arm contains a custom high speed linear motor with 25 mm stroke and equipped with a precision displacement encoder. Light reflected from the cornea and the retina is combined with the reference beam to generate low coherence interferograms. Two galvo scanners are employed to steer the light to different angles so that the eye length over a field of view of 20° × 20° can be measured. The system has an axial resolution of 6.8 μm (in air) and the motor provides accurate movement, allowing for precise and repeatable measurement of coherence peak positions. Example scans from a tree shrew are presented.
NASA Astrophysics Data System (ADS)
Dong, Leng; Chen, Yan; Dias, Sarah; Stone, William; Dias, Joseph; Rout, John; Gale, Alastair G.
2017-03-01
Visual search techniques and FROC analysis have been widely used in radiology to understand medical image perceptual behaviour and diagnostic performance. The potential of exploiting the advantages of both methodologies is of great interest to medical researchers. In this study, eye tracking data of eight dental practitioners was investigated. The visual search measures and their analyses are considered here. Each participant interpreted 20 dental radiographs which were chosen by an expert dental radiologist. Various eye movement measurements were obtained based on image area of interest (AOI) information. FROC analysis was then carried out by using these eye movement measurements as a direct input source. The performance of FROC methods using different input parameters was tested. The results showed that there were significant differences in FROC measures, based on eye movement data, between groups with different experience levels. Namely, the area under the curve (AUC) score evidenced higher values for experienced group for the measurements of fixation and dwell time. Also, positive correlations were found for AUC scores between the eye movement data conducted FROC and rating based FROC. FROC analysis using eye movement measurements as input variables can act as a potential performance indicator to deliver assessment in medical imaging interpretation and assess training procedures. Visual search data analyses lead to new ways of combining eye movement data and FROC methods to provide an alternative dimension to assess performance and visual search behaviour in the area of medical imaging perceptual tasks.
Sesin, Anaelis; Adjouadi, Malek; Cabrerizo, Mercedes; Ayala, Melvin; Barreto, Armando
2008-01-01
This study developed an adaptive real-time human-computer interface (HCI) that serves as an assistive technology tool for people with severe motor disability. The proposed HCI design uses eye gaze as the primary computer input device. Controlling the mouse cursor with raw eye coordinates results in sporadic motion of the pointer because of the saccadic nature of the eye. Even though eye movements are subtle and completely imperceptible under normal circumstances, they considerably affect the accuracy of an eye-gaze-based HCI. The proposed HCI system is novel because it adapts to each specific user's different and potentially changing jitter characteristics through the configuration and training of an artificial neural network (ANN) that is structured to minimize the mouse jitter. This task is based on feeding the ANN a user's initially recorded eye-gaze behavior through a short training session. The ANN finds the relationship between the gaze coordinates and the mouse cursor position based on the multilayer perceptron model. An embedded graphical interface is used during the training session to generate user profiles that make up these unique ANN configurations. The results with 12 subjects in test 1, which involved following a moving target, showed an average jitter reduction of 35%; the results with 9 subjects in test 2, which involved following the contour of a square object, showed an average jitter reduction of 53%. For both results, the outcomes led to trajectories that were significantly smoother and apt at reaching fixed or moving targets with relative ease and within a 5% error margin or deviation from desired trajectories. The positive effects of such jitter reduction are presented graphically for visual appreciation.
Mrugacz, Malgorzata; Bakunowicz-Lazarczyk, Alina
2005-01-01
The aim of this study was to quantitatively assess and compare the thickness of the retinal nerve fiber layer (RNFL) in normal and glaucomatous eyes of children using the optical coherence tomograph. The mean RNFL thickness of normal eyes (n=26) was compared with that of glaucomatous eyes (n=26). The eyes were classified into diagnostic groups based on conventional ophthalmological physical examination, Humphrey 30-2 visual fields, stereoscopic optic nerve head photography, and optical coherence tomography. The mean RNFL was significantly thinner in glaucomatous eyes than in normal eyes: 95+/-26.3 and 132+/-24.5 microm, respectively. More specifically, the RNFL was significantly thinner in glaucomatous eyes than in normal eyes in the inferior quadrant: 87+/-23.5 and 122+/-24.2 microm, respectively. The mean and inferior quadrant RFNL thicknesses as measured by the optical coherence tomograph showed a statistically significant correlation with glaucoma. Optical coherence tomography may contribute to tracking of juvenile glaucoma progression. Copyright (c) 2005 S. Karger AG, Basel.
Murakami, Yohko; Wang, Dandan; Burkemper, Bruce; Lin, Shan C; Varma, Rohit
2016-08-01
To compare grading of goniophotographic images and gonioscopy in assessing the iridocorneal angle. In a population-based, cross-sectional study, participants underwent gonioscopy and goniophotographic imaging during the same visit. The iridocorneal angle was classified as closed if the posterior trabecular meshwork could not be seen. A single masked observer graded the goniophotographic images, and each eye was classified as having angle closure based on the number of closed quadrants. Agreement between the methods was analyzed by calculating kappa (κ) and first-order agreement coefficient (AC1) statistics and comparison of area under receiver operating characteristic curves (AUC). A total of 4149 Chinese Americans (3994 eyes) were included in this study. The agreement for angle closure diagnosis between gonioscopy and EyeCam was moderate to excellent (κ = 0.60, AC1 0.90, AUC 0.76-0.80). Detection of iridocorneal angle closure based on goniophotographic imaging shows moderate to very good agreement with angle closure assessment using gonioscopy.
Sharma, S; Brown, G C; Brown, M M; Hollands, H; Shah, G K
2001-11-01
Photodynamic therapy (PDT) has recently been demonstrated to be beneficial for the treatment of subfoveal choroidal neovascularization secondary to age-related macular degeneration (AMD). Herein, we determine the cost-effectiveness of PDT for the treatment of subfoveal choroidal neovascularization (CNV) in patients with disciform degeneration in one eye and whose second and better-seeing eye develops visual loss secondary to predominantly classic subfoveal CNV. The analysis was performed from the perspective of a for-profit third-party insurer. Cost-utility Markov models were created to determine the cost-effectiveness of PDT under two different scenarios, by using efficacy data derived from the Treatment of Age-Related Macular Degeneration with Photodynamic Therapy (TAP) Study and patient-based utilities. Decision analyses were performed by incorporating data from the TAP Study, expected longevity data, and patient-based utilities. Cost-effective models were then created by incorporating incremental medical costs. Various sensitivity analyses were carried out to determine the robustness of our models. A Monte Carlo simulation was also used to determine whether there was a significant difference in quality-of-life adjusted years (QALYs) gained between PDT therapy and the placebo. For the hypothetical patient whose second and better-seeing eye becomes affected and who has 20/40 vision at baseline in this affected eye (base case 1), PDT was associated with a 10.7% relative increase in their quality-of-life (treatment conferred an additional undiscounted 0.1342 QALYs over a 2-year period). For the hypothetical patient whose second and better-seeing eye becomes affected and who has 20/200 vision at baseline in this affected eye (base case 2), PDT was associated with a 7.8% relative increase in their quality-of-life (treatment conferred an additional undiscounted 0.0669 QALYs over a 2-year period). Sensitivity analysis showed our models were robust and that PDT was usually the dominant treatment choice. Our cost-effective model demonstrated that the cost for a QALY was $86,721 (US dollars discounted at 3%) for base case 1, assuming 5.5 treatments; and $173,984 (USD discounted at 3%) for base case 2. PDT will cost a third-party insurer $86,721 for an AMD patient with 20/40 vision in the better-seeing eye to obtain one QALY and $173,984 for an AMD patient with 20/200 vision in the better-seeing eye to obtain one QALY. PDT can be considered to be a treatment that is of only minimal cost-effectiveness for AMD patients who have subfoveal CNV in their second and better-seeing eyes and who have good presenting visual acuity at baseline. It is a cost-ineffective treatment for AMD patients who have poor visual acuities in their affected better-seeing eyes.
NASA Astrophysics Data System (ADS)
Sugiyama, S.; Hong, Y.-J.; Kasaragod, D.; Makita, S.; Miura, M.; Ikuno, Y.; Yasuno, Y.
2016-03-01
Quantitative evaluation of optical properties of choroid and sclera are performed by multifunctional optical coherence tomography. Five normal eyes, five glaucoma eyes and one choroidal atrophy eye are examined. The refractive error was found to be correlated with choroidal birefringence, polarization uniformity, and flow in addition to scleral birefringence among normal eyes. The significant differences were observed between the normal and the glaucoma eyes, as for choroidal polarization uniformity, flow and scleral birefringence. An automatic segmentation algorithm of retinal pigment epithelium and chorioscleral interface based on multifunctional signals is also presented.
NASA Astrophysics Data System (ADS)
Saldan, Yosyp R.; Pavlov, Sergii V.; Vovkotrub, Dina V.; Saldan, Yulia Y.; Vassilenko, Valentina B.; Mazur, Nadia I.; Nikolaichuk, Daria V.; Wójcik, Waldemar; Romaniuk, Ryszard; Suleimenov, Batyrbek; Bainazarov, Ulan
2017-08-01
Process of eye tomogram obtaining by means of optical coherent tomography is studied. Stages of idiopathic macula holes formation in the process of eye grounds diagnostics are considered. Main stages of retina pathology progression are determined: Fuzzy logic units for obtaining reliable conclusions regarding the result of diagnosis are developed. By the results of theoretical and practical research system and technique of retinal macular region of the eye state analysis is developed ; application of the system, based on fuzzy logic device, improves the efficiency of eye retina complex.
Hirtl, Rene; Schmid, Gernot
2013-09-21
A modern wireless intra-ocular pressure monitoring system, based on 13.56 MHz inductively coupled data transmission, was dosimetrically analyzed with respect to the specific absorption rate (SAR) induced inside the head and the eye due to the electromagnetic field exposure caused by the reader antenna of the transmission system. The analysis was based on numerical finite difference time domain computations using a high resolution anatomical eye model integrated in a modern commercially available anatomical model of a male head. Three different reader antenna configurations, a 7-turn elliptic (30 mm × 50 mm) antenna at 12 mm distance from the eye, a flexible circular antenna (60 mm diameter, 8 turns on 2 mm substrate) directly attached to the skin, and a circular 7-turn antenna (30 mm diameter at 12 mm distance to the eye) were analyzed, respectively. Possible influences of the eye-lid status (closed or opened) and the transponder antenna contained in a contact lens directly attached to the eye were taken into account. The results clearly demonstrated that for typical reader antenna currents required for proper data transmission, the SAR values remain far below the limits for localized exposure of the head, as defined by the International Commission for Non-Ionizing Radiation Protection. Particularly the induced SAR inside the eye was found to be substantially (orders of magnitudes for typical reader antenna currents in the order of 1 A turn) below values which have been reported to be critical with respect to thermally induced adverse health effects in eye tissues.
Behrens, R
2013-07-01
In this work, conversion coefficients from electron fluence to absorbed dose to the eye lens were calculated using Monte Carlo simulations based on a detailed stylised eye model and a very simple but whole body phantom. These data supersede and complement data published earlier based on the simulation of only a single stylised eye. The new data differ from the old ones by not more than 3, 4, 7 and 16 % for angles of radiation incidence of α=0°, 15°, 30° and 45°, respectively, due to the inclusion of the whole body phantom. The data presented in the present work also complement those of a recent report of the International Commission on Radiological Protection (ICRP) (ICRP Publication 116), where conversion coefficients from electron fluence to absorbed dose to the lens of the eye are shown for solely 0°, 180° and isotropic radiation incidence (but for a much broader range of energies). In this article, values are provided for angles of incidence of 0° up to 180° in steps of 15° and for rotational geometry; no systematic deviation was observed from the values given in ICRP Publication 116 for 0° (based on the application of a bare eye) and 180° (based on the application of a voxel whole body phantom). Data are given for monoenergetic electrons from 0.1 up to 10 MeV and for a broad parallel beam geometry in vacuum.
Assessment of the vision-specific quality of life using clustered visual field in glaucoma patients.
Sawada, Hideko; Yoshino, Takaiko; Fukuchi, Takeo; Abe, Haruki
2014-02-01
To investigate the significance of vision-specific quality of life (QOL) in glaucoma patients based on the location of visual field defects. We examined 336 eyes of 168 patients. The 25-item National Eye Institute Visual Function Questionnaire was used to evaluate patients' QOL. Visual field testing was performed using the Humphrey Field Analyzer; the visual field was divided into 10 clusters. We defined the eye with better mean deviation as the better eye and the fellow eye as the worse eye. A single linear regression analysis was applied to assess the significance of the relationship between QOL and the clustered visual field. The strongest correlation was observed in the lower paracentral visual field in the better eye. The lower peripheral visual field in the better eye also showed a good correlation. Correlation coefficients in the better eye were generally higher than those in the worse eye. For driving, the upper temporal visual field in the better eye was the most strongly correlated (r=0.509). For role limitation and peripheral vision, the lower peripheral visual field in the better eye had the highest correlation coefficients at 0.459 and 0.425, respectively. Overall, clusters in the lower hemifield in the better eye were more strongly correlated with QOL than those in the worse eye. In particular, the lower paracentral visual field in the better eye was correlated most strongly of all. Driving, however, strongly correlated with the upper hemifield in the better eye.
An Examination of Cognitive Processing of Multimedia Information Based on Viewers' Eye Movements
ERIC Educational Resources Information Center
Liu, Han-Chin; Chuang, Hsueh-Hua
2011-01-01
This study utilized qualitative and quantitative designs and eye-tracking technology to understand how viewers process multimedia information. Eye movement data were collected from eight college students (non-science majors) while they were viewing web pages containing different types of text and illustrations depicting the mechanism of…
Predictors of Verb-Mediated Anticipatory Eye Movements in the Visual World
ERIC Educational Resources Information Center
Hintz, Florian; Meyer, Antje S.; Huettig, Falk
2017-01-01
Many studies have demonstrated that listeners use information extracted from verbs to guide anticipatory eye movements to objects in the visual context that satisfy the selection restrictions of the verb. An important question is what underlies such verb-mediated anticipatory eye gaze. Based on empirical and theoretical suggestions, we…
Prevalence and risk factors associated with dry eye symptoms: a population based study in Indonesia
Lee, A J; Lee, J; Saw, S-M; Gazzard, G; Koh, D; Widjaja, D; Tan, D T H
2002-01-01
Aim: To determine the prevalence and identify associated risk factors for dry eye syndrome in a population in Sumatra, Indonesia. Methods: A one stage cluster sampling procedure was conducted to randomly select 100 households in each of the five rural villages and one provincial town of the Riau province, Indonesia, from April to June 2001. Interviewers collected demographic, lifestyle, and medical data from 1058 participants aged 21 years or over. Symptoms of dry eye were assessed using a six item validated questionnaire. Presence of one or more of the six dry eye symptoms often or all the time was analysed. Presence of pterygium was documented. Results: Prevalence of one or more of the six dry eye symptoms often or all the time adjusted for age was 27.5% (95% confidence interval (CI) 24.8 to 30.2). After adjusting for all significant variables, independent risk factors for dry eye were pterygium (p<0.001, multivariate odds ratio (OR) 1.8; 95% CI 1.4 to 2.5) and a history of current cigarette smoking (p=0.05, multivariate OR 1.5; 95% CI 1.0 to 2.2). Conclusions: This population based study provides prevalence rates of dry eye symptoms in a tropical developing nation. From our findings, pterygium is a possible independent risk factor for dry eye symptoms. PMID:12446361
Video-Based Eye Tracking in Sex Research: A Systematic Literature Review.
Wenzlaff, Frederike; Briken, Peer; Dekker, Arne
2015-12-21
Although eye tracking has been used for decades, it has gained popularity in the area of sex research only recently. The aim of this article is to examine the potential merits of eye tracking for this field. We present a systematic review of the current use of video-based eye-tracking technology in this area, evaluate the findings, and identify future research opportunities. A total of 34 relevant studies published between 2006 and 2014 were identified for inclusion by means of online databases and other methods. We grouped them into three main areas of research: body perception and attractiveness, forensic research, and sexual orientation. Despite the methodological and theoretical differences across the studies, eye tracking has been shown to be a promising tool for sex research. The article suggests there is much potential for further studies to employ this technique because it is noninvasive and yet still allows for the assessment of both conscious and unconscious perceptional processes. Furthermore, eye tracking can be implemented in investigations of various theoretical backgrounds, ranging from biology to the social sciences.
NASA Astrophysics Data System (ADS)
Lim, Jeong-Hwan; Hwang, Han-Jeong; Han, Chang-Hee; Jung, Ki-Young; Im, Chang-Hwan
2013-04-01
Objective. Some patients suffering from severe neuromuscular diseases have difficulty controlling not only their bodies but also their eyes. Since these patients have difficulty gazing at specific visual stimuli or keeping their eyes open for a long time, they are unable to use the typical steady-state visual evoked potential (SSVEP)-based brain-computer interface (BCI) systems. In this study, we introduce a new paradigm for SSVEP-based BCI, which can be potentially suitable for disabled individuals with impaired oculomotor function. Approach. The proposed electroencephalography (EEG)-based BCI system allows users to express their binary intentions without needing to open their eyes. A pair of glasses with two light emitting diodes flickering at different frequencies was used to present visual stimuli to participants with their eyes closed, and we classified the recorded EEG patterns in the online experiments conducted with five healthy participants and one patient with severe amyotrophic lateral sclerosis (ALS). Main results. Through offline experiments performed with 11 participants, we confirmed that human SSVEP could be modulated by visual selective attention to a specific light stimulus penetrating through the eyelids. Furthermore, the recorded EEG patterns could be classified with accuracy high enough for use in a practical BCI system. After customizing the parameters of the proposed SSVEP-based BCI paradigm based on the offline analysis results, binary intentions of five healthy participants were classified in real time. The average information transfer rate of our online experiments reached 10.83 bits min-1. A preliminary online experiment conducted with an ALS patient showed a classification accuracy of 80%. Significance. The results of our offline and online experiments demonstrated the feasibility of our proposed SSVEP-based BCI paradigm. It is expected that our ‘eyes-closed’ SSVEP-based BCI system can be potentially used for communication of disabled individuals with impaired oculomotor function.
Lim, Jeong-Hwan; Hwang, Han-Jeong; Han, Chang-Hee; Jung, Ki-Young; Im, Chang-Hwan
2013-04-01
Some patients suffering from severe neuromuscular diseases have difficulty controlling not only their bodies but also their eyes. Since these patients have difficulty gazing at specific visual stimuli or keeping their eyes open for a long time, they are unable to use the typical steady-state visual evoked potential (SSVEP)-based brain-computer interface (BCI) systems. In this study, we introduce a new paradigm for SSVEP-based BCI, which can be potentially suitable for disabled individuals with impaired oculomotor function. The proposed electroencephalography (EEG)-based BCI system allows users to express their binary intentions without needing to open their eyes. A pair of glasses with two light emitting diodes flickering at different frequencies was used to present visual stimuli to participants with their eyes closed, and we classified the recorded EEG patterns in the online experiments conducted with five healthy participants and one patient with severe amyotrophic lateral sclerosis (ALS). Through offline experiments performed with 11 participants, we confirmed that human SSVEP could be modulated by visual selective attention to a specific light stimulus penetrating through the eyelids. Furthermore, the recorded EEG patterns could be classified with accuracy high enough for use in a practical BCI system. After customizing the parameters of the proposed SSVEP-based BCI paradigm based on the offline analysis results, binary intentions of five healthy participants were classified in real time. The average information transfer rate of our online experiments reached 10.83 bits min(-1). A preliminary online experiment conducted with an ALS patient showed a classification accuracy of 80%. The results of our offline and online experiments demonstrated the feasibility of our proposed SSVEP-based BCI paradigm. It is expected that our 'eyes-closed' SSVEP-based BCI system can be potentially used for communication of disabled individuals with impaired oculomotor function.
Double-pass measurement of human eye aberrations: limitations and practical realization
NASA Astrophysics Data System (ADS)
Letfullin, Renat R.; Belyakov, Alexey I.; Cherezova, Tatyana Y.; Kudryashov, Alexis V.
2004-11-01
The problem of correct eye aberrations measurement is very important with the rising widespread of a surgical procedure for reducing refractive error in the eye, so called, LASIK (laser-assisted in situ keratomileusis). The double-pass technique commonly used for measuring aberrations of a human eye involves some uncertainties. One of them is loosing the information about odd human eye aberrations. We report about investigations of the applicability limit of the double-pass measurements depending upon the aberrations status introduced by human eye and actual size of the entrance pupil. We evaluate the double-pass effects for various aberrations and different pupil diameters. It is shown that for small pupils the double-pass effects are negligible. The testing and alignment of aberrometer was performed using the schematic eye, developed in our lab. We also introduced a model of human eye based on bimorph flexible mirror. We perform calculations to demonstrate that our schematic eye is capable of reproducing spatial-temporal statistics of aberrations of living eye with normal vision or even myopic or hypermetropic or with high aberrations ones.
Noopur, Gupta; Praveen, Vashist; Radhika, Tandon; Sanjeev K, Gupta; Mani, Kalaivani; Deepak, Kumar
2018-06-01
To assess awareness, barriers, and misconceptions related to eye donation in people with corneal disease as compared to controls in a population setting. A population-based study was conducted in 25 randomly selected clusters of Rural Gurgaon, Haryana, India, as part of the CORE (Cornea Opacity Rural Epidemiological) study. In addition to ophthalmic examination, knowledge and perceptions regarding eye donation were assessed through a validated questionnaire. The questionnaire captured the sociodemographic factors influencing awareness regarding eye donation in participants with corneal disease and twice the number of age- and gender-matched controls recruited from the same study clusters. Descriptive statistics were computed along with multivariable logistic regression analysis to determine associated factors for awareness of eye donation. In the CORE study, 452 participants had corneal opacities on ocular examination. Of these, 442 were assessed for eye donation awareness. Additionally, 884 age- and gender-matched controls were recruited. The mean age of cases and controls was 60.9 ± 15.5 and 59.6 ± 14.3 years, respectively. Awareness of eye donation in cases and controls was 46.4% (n = 205 of 442) and 52.3% (n = 462 of 884), respectively (P = 0.044). Educational status was an important factor determining knowledge about eye donation in both cases and controls (P = < 0.001). Major barriers reported for not pledging eyes were lack of willingness (36.7%) and ignorance (15.3%). Common misconceptions like eyes could be donated before death or even after 24 h of death and that any type of blindness could be treated with corneal transplantation were prevalent. The study demonstrated that although there is substantial awareness about eye donation, there are numerous barriers in this population that need to be resolved to improve donation rates. Additional efforts are needed to translate this awareness into actual eye donation in both cases with corneal disease and controls.
Prevalence of dry eye syndrome in an adult population.
Hashemi, Hassan; Khabazkhoob, Mehdi; Kheirkhah, Ahmad; Emamian, Mohammad Hassan; Mehravaran, Shiva; Shariati, Mohammad; Fotouhi, Akbar
2014-04-01
To determine the prevalence of dry eye syndrome in the general 40- to 64-year-old population of Shahroud, Iran. Population-based cross-sectional study. Through cluster sampling, 6311 people were selected and 5190 participated. Assessment of dry eye was done in a random subsample of 1008 people. Subjective assessment for dry eye syndrome was performed using Ocular Surface Disease Index questionnaire. In addition, the following objective tests of dry eye syndrome were employed: Schirmer test, tear break-up time, and fluorescein and Rose Bengal staining using the Oxford grading scheme. Those with an Ocular Surface Disease Index score ≥23 were considered symptomatic, and dry eye syndrome was defined as having symptoms and at least one positive objective sign. The prevalence of dry eye syndrome was 8.7% (95% confidence interval 6.9-10.6). Assessment of signs showed an abnormal Schirmer score in 17.8% (95% confidence interval 15.5-20.0), tear break-up time in 34.2% (95% confidence interval 29.5-38.8), corneal fluorescein staining (≥1) in 11.3% (95% confidence interval 8.5-14.1) and Rose Bengal staining (≥3 for cornea and/or conjunctiva) in 4.9% (95% confidence interval 3.4-6.5). According to the Ocular Surface Disease Index scores, 18.3% (95% confidence interval 15.9-20.6) had dry eye syndrome symptoms. The prevalence of dry eye syndrome was significantly higher in women (P = 0.010) and not significantly associated with age (P = 0.291). The objective dry eye syndrome signs significantly increased with age. Based on the findings, the prevalence of dry eye syndrome in the studied population is in the mid-range. The prevalence is higher in women. Also, objective tests tend to turn abnormal at higher age. Pterygium is associated with dry eye syndrome and increased its symptoms. © 2013 Royal Australian and New Zealand College of Ophthalmologists.
[Emphasis on standardization and refinement in the diagnosis and treatment of dry eye].
Liu, Z G
2017-09-11
Dry eye is the second most common ocular disease. In China, the incidence rate of dry eye has reached 21% to 30%, and dry eye patients have accounted for more than 30% of the total ophthalmology outpatients. Dry eye has become a common health problem that affects the working efficiency and life quality of Chinese people. Over the past decade, due to the rapid development of diagnostic equipments and new treatments for dry eye, dry eye has become one of the areas with greatest concerns in ophthalmology, and many eye institutions have set up their dry eye clinics. Although the diagnosis and treatment of dry eye has been improved in recent years, the awareness of dry eye in Chinese ophthalmologists is still too simple. In the diagnosis, the interrogation and basic examination are not given enough attention, and we are over-relying on equipments. Clinical examination and instrument operation also have not been standardized. This article emphasizes that we should pay attention to the interrogation, basic examination and standardization of clinical examination and equipment operation in diagnosing dry eye. The treatment regimen should be mostly refined and optimized to be individualized and comprehensive based on the causes, types and severity of dry eye. In addition, the physical and adjuvant therapy of dry eye should be given sufficient attention and applied reasonably. (Chin J Ophthalmol, 2017, 53: 641-644) .
Indian Soldiers Need Eye Protection.
Jha, Kirti Nath
2017-02-01
Combat-related eye injuries entail enormous financial, social and psychological cost. Military Combat Eye Protection (MCEP) decreases both the incidence and severity of eye injuries. Experts have recognised the need for MCEP for Indian soldiers. We aim to review the combat-related eye injuries and combat eye protection among the Indian soldiers. Global practices of MCEP are also reviewed. We also aim to offer our recommendations for Indian soldiers. We carried out Medline search for combat-related eye injuries and MCEP and separately searched for eye injuries among Indian soldiers during war and other operations. We present the findings as results. Recommendations are based on the opinions of the experts. Combat-related eye injuries increased from 3% of injured in the 1965 Indo-Pakistan War to 4.8% in 1971 war. During peace-keeping operations in Sri Lanka (1987-89) eye injuries increased to 10.5% of the injured. Statistics on eye injuries during counterinsurgency operations are not available. MCEP have shown reduction in eye injuries, and thus MCEP forms a part of personal equipment of the soldiers in developed countries. Indian soldiers do not have provision of MCEP. Combat-related eye injuries among Indian Army soldiers have been increasing. Data on eye injuries during counterinsurgency operations are not available. Indian soldiers do not have provision of MCEP. Provision of MCEP is therefore desirable. Awareness program among the commanders and the soldiers shall result in attitudinal changes and increased compliance.
Indian Soldiers Need Eye Protection
2017-01-01
Combat-related eye injuries entail enormous financial, social and psychological cost. Military Combat Eye Protection (MCEP) decreases both the incidence and severity of eye injuries. Experts have recognised the need for MCEP for Indian soldiers. We aim to review the combat-related eye injuries and combat eye protection among the Indian soldiers. Global practices of MCEP are also reviewed. We also aim to offer our recommendations for Indian soldiers. We carried out Medline search for combat-related eye injuries and MCEP and separately searched for eye injuries among Indian soldiers during war and other operations. We present the findings as results. Recommendations are based on the opinions of the experts. Combat-related eye injuries increased from 3% of injured in the 1965 Indo-Pakistan War to 4.8% in 1971 war. During peace-keeping operations in Sri Lanka (1987-89) eye injuries increased to 10.5% of the injured. Statistics on eye injuries during counterinsurgency operations are not available. MCEP have shown reduction in eye injuries, and thus MCEP forms a part of personal equipment of the soldiers in developed countries. Indian soldiers do not have provision of MCEP. Combat-related eye injuries among Indian Army soldiers have been increasing. Data on eye injuries during counterinsurgency operations are not available. Indian soldiers do not have provision of MCEP. Provision of MCEP is therefore desirable. Awareness program among the commanders and the soldiers shall result in attitudinal changes and increased compliance. PMID:28384904
Hu, Yang; Zhang, Jing; Lv, Yuan-Zheng; Huang, Xiao-Huan; Hu, Sheng-Li
2016-03-15
A new colorimetric probe 1 based on rhodamine B lactam was developed for naked-eye detection of Cu(2+). The optical feature of 1 for Cu(2+) was investigated by UV-vis absorption spectroscopy. Upon the addition of Cu(2+), the 1 displayed a distinct color change from colorless to pink, which can be directly detected by the naked eye. The stoichiometry of 1 to Cu(2+) complex was found to be 1:1 and the naked-eye detection limit was determined as low as 2 μM. The results suggest that the probe 1 may provide a convenient method for visual detection of Cu(2+) with high sensitivity. Copyright © 2015 Elsevier B.V. All rights reserved.
Online Learners’ Reading Ability Detection Based on Eye-Tracking Sensors
Zhan, Zehui; Zhang, Lei; Mei, Hu; Fong, Patrick S. W.
2016-01-01
The detection of university online learners’ reading ability is generally problematic and time-consuming. Thus the eye-tracking sensors have been employed in this study, to record temporal and spatial human eye movements. Learners’ pupils, blinks, fixation, saccade, and regression are recognized as primary indicators for detecting reading abilities. A computational model is established according to the empirical eye-tracking data, and applying the multi-feature regularization machine learning mechanism based on a Low-rank Constraint. The model presents good generalization ability with an error of only 4.9% when randomly running 100 times. It has obvious advantages in saving time and improving precision, with only 20 min of testing required for prediction of an individual learner’s reading ability. PMID:27626418
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lesperance, Marielle; Inglis-Whalen, M.; Thomson, R. M., E-mail: rthomson@physics.carleton.ca
Purpose : To investigate the effects of the composition and geometry of ocular media and tissues surrounding the eye on dose distributions for COMS eye plaque brachytherapy with{sup 125}I, {sup 103}Pd, or {sup 131}Cs seeds, and to investigate doses to ocular structures. Methods : An anatomically and compositionally realistic voxelized eye model with a medial tumor is developed based on a literature review. Mass energy absorption and attenuation coefficients for ocular media are calculated. Radiation transport and dose deposition are simulated using the EGSnrc Monte Carlo user-code BrachyDose for a fully loaded COMS eye plaque within a water phantom andmore » our full eye model for the three radionuclides. A TG-43 simulation with the same seed configuration in a water phantom neglecting the plaque and interseed effects is also performed. The impact on dose distributions of varying tumor position, as well as tumor and surrounding tissue media is investigated. Each simulation and radionuclide is compared using isodose contours, dose volume histograms for the lens and tumor, maximum, minimum, and average doses to structures of interest, and doses to voxels of interest within the eye. Results : Mass energy absorption and attenuation coefficients of the ocular media differ from those of water by as much as 12% within the 20–30 keV photon energy range. For all radionuclides studied, average doses to the tumor and lens regions in the full eye model differ from those for the plaque in water by 8%–10% and 13%–14%, respectively; the average doses to the tumor and lens regions differ between the full eye model and the TG-43 simulation by 2%–17% and 29%–34%, respectively. Replacing the surrounding tissues in the eye model with water increases the maximum and average doses to the lens by 2% and 3%, respectively. Substituting the tumor medium in the eye model for water, soft tissue, or an alternate melanoma composition affects tumor dose compared to the default eye model simulation by up to 16%. In the full eye model simulations, the average dose to the lens is larger by 7%–9% than the dose to the center of the lens, and the maximum dose to the optic nerve is 17%–22% higher than the dose to the optic disk for all radionuclides. In general, when normalized to the same prescription dose at the tumor apex, doses delivered to all structures of interest in the full eye model are lowest for{sup 103}Pd and highest for {sup 131}Cs, except for the tumor where the average dose is highest for {sup 103}Pd and lowest for {sup 131}Cs. Conclusions : The eye is not radiologically water-equivalent, as doses from simulations of the plaque in the full eye model differ considerably from doses for the plaque in a water phantom and from simulated TG-43 calculated doses. This demonstrates the importance of model-based dose calculations for eye plaque brachytherapy, for which accurate elemental compositions of ocular media are necessary.« less
Eyes wide shut: amygdala mediates eyes-closed effect on emotional experience with music.
Lerner, Yulia; Papo, David; Zhdanov, Andrey; Belozersky, Libi; Hendler, Talma
2009-07-15
The perceived emotional value of stimuli and, as a consequence the subjective emotional experience with them, can be affected by context-dependent styles of processing. Therefore, the investigation of the neural correlates of emotional experience requires accounting for such a variable, a matter of an experimental challenge. Closing the eyes affects the style of attending to auditory stimuli by modifying the perceptual relationship with the environment without changing the stimulus itself. In the current study, we used fMRI to characterize the neural mediators of such modification on the experience of emotionality in music. We assumed that closed eyes position will reveal interplay between different levels of neural processing of emotions. More specifically, we focused on the amygdala as a central node of the limbic system and on its co-activation with the Locus Ceruleus (LC) and Ventral Prefrontal Cortex (VPFC); regions involved in processing of, respectively, 'low', visceral-, and 'high', cognitive-related, values of emotional stimuli. Fifteen healthy subjects listened to negative and neutral music excerpts with eyes closed or open. As expected, behavioral results showed that closing the eyes while listening to emotional music resulted in enhanced rating of emotionality, specifically of negative music. In correspondence, fMRI results showed greater activation in the amygdala when subjects listened to the emotional music with eyes closed relative to eyes open. More so, by using voxel-based correlation and a dynamic causal model analyses we demonstrated that increased amygdala activation to negative music with eyes closed led to increased activations in the LC and VPFC. This finding supports a system-based model of perceived emotionality in which the amygdala has a central role in mediating the effect of context-based processing style by recruiting neural operations involved in both visceral (i.e. 'low') and cognitive (i.e. 'high') related processes of emotions.
Jadeja, Jagruti N; Patel, Bharati D; Shanbhag, Swapna S
2013-12-01
Donor tissue scarcity, Eye Bank Specular Microscopy as yet not made mandatory and tissue utilization often based on clinical judgment only. Prospectively analyze alteration in clinical grading of donor corneas and hence utilization, based on Eye Bank Specular Microscopy (EBSM) and to infer if EBSM should be mandatory in all eye banks. 200 consecutive otherwise 'suitable for surgery' donor eyes were graded clinically. On quantitative and qualitative analysis of endothelial cells by EBSM, final grading was adjusted. Impact on subsequent utilization for various surgeries was analyzed with regard to Age of Donor, Death to Enucleation Time, Death to Preservation Time and Lens Status of Donor Eye. 76 eyes (38%) (P < 0.05) had significant change in grading. 12/59 (20.30%) tissues from donors <=40 years showed Cell Density (CD) between 1801-2500. 19/76 (25%) tissues from donor >60 years showed CD >= 2500. From donor >=81 years, 2/13 (15.3%) eyes showed CD between 2501-3000 and 1 (7.6%) eye showed CD > 3000. Owing to better grading after EBSM, 13/14 (92.85%) tissues with DTET >6 hours and 5/5 (100%) tissues with DTPT > 16 hours were transplanted. Out of 45 (22.5%) pseudo-phakic tissues, 21 (46.67%) tissues were used for Therapeutic/Tectonic Penetrating Keratoplasty (PKP) while 24 (53.33%) tissues were used for Optical PKP. EBSM significantly alters final grading of tissues and its subsequent utilization. Acquiring huge importance in areas where adequate supply of corneas is lacking, EBSM becomes an indispensable tool for optimizing availability of qualified tissues for surgery. EBSM should be made a mandatory analysis.
Xue, Ally L; Downie, Laura E; Ormonde, Susan E; Craig, Jennifer P
2017-03-01
The aim of this cross-sectional survey was to evaluate the self-reported clinical practices of New Zealand optometrists and ophthalmologists with respect to the diagnosis and management of dry eye disease. It also sought to compare these behaviours with the current research evidence base. An anonymous survey was distributed electronically to New Zealand eye care clinicians (optometrists n = 614, ophthalmologists n = 113) to determine practitioner interest in dry eye disease, practice experience, practice modality, preferred diagnostic and management strategies, and information used to guide patient care. Respondents from both professions (response rates, optometrists: 26%, ophthalmologists: 26%) demonstrated similarly strong knowledge of tear film assessment. Ninety percent of respondents ranked patient symptoms and meibomian gland evaluation as the most valuable and common diagnostic approaches. Conversely, standardised grading scales and validated dry eye questionnaires were infrequently adopted. Both professions tailored dry eye management according to severity, indicating eyelid hygiene and non-preserved lubricants as mainstay therapies. Ophthalmologists prescribed systemic tetracyclines significantly more often than optometrists for moderate (48% vs 11%) and severe (72% vs 32%) dry eye (p < 0.05). Continuing education conferences were acknowledged as the primary information source used to guide dry eye management practices by both professions. Consistent with evidence-based guidelines, New Zealand eye care professionals combine subjective and objective techniques to diagnose and stratify dry eye management according to disease severity. There is potential to improve dissemination of research evidence into clinical practice, with continuing education via professional conferences the favoured mode of delivery. © 2017 The Authors Ophthalmic & Physiological Optics © 2017 The College of Optometrists.
Paediatric eye injuries in Finland - Helsinki eye trauma study.
Haavisto, Anna-Kaisa; Sahraravand, Ahmad; Holopainen, Juha M; Leivo, Tiina
2017-06-01
To determine the current population-based epidemiology, treatment, use of resources and outcomes of children's eye injuries in Finland. The study included all new patients, 16 years of age or under, with ocular or orbital traumas taken into care to the Helsinki University Eye Hospital (population base 1.5 million people) in 1 year. The follow-up period was 3 months. Two hundred and two children's eye injuries were treated. The eye injury incidence was 5.2-8.3 per 10 000 per year, including all minor and major eye traumas. Eye injury most likely occurred at the junior high school age (13-16 years). Thirty-three percentage of accidents took place at home and 24% at school or in day care. The most common causes were sports equipment (15%), contact with human body (12%) and superficial foreign bodies (11%). Excluding minor injuries, contusion was the most common diagnosis (n = 60, 30%). Eighty-seven percentage of contusion patients were estimated to need lifelong follow-up due to elevated glaucoma risk. Nine percentage of all patients had a permanent disability. Guns, fireworks, tools and pellet guns were relatively the most dangerous objects. Pellet guns caused 6% of eye injuries, 36% of them causing permanent impairment. The number of outpatient visits was altogether 443, inpatient days were 49, and 60 children had major surgeries. Use of protective eyewear would have prevented or diminished eye traumas caused by pellet gun, floorball, most of the firework and in many superficial foreign body. The use of pellet guns and protective eyewear should be more supervised. Fireworks and tools are not suitable toys for children. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Eye-scan behavior in a flight simulation task as a function of level of training
NASA Technical Reports Server (NTRS)
Comstock, J. R., Jr.; Coates, G. D.; Kirby, R. H.
1985-01-01
The present study explored eye-scan behavior as a function of level of subject training. Oculometric (eye-scan) measures were recorded from each of ten subjects during training trials on a CRT-based flight simulation task. The task developed for the study incorporated subtasks representative of specific activities performed by pilots, but which could be performed at asymptotic levels within relatively short periods of training. Changes in eye-scan behavior were examined as initially untrained subjects developed skill in the task. Eye-scan predictors of performance on the task were found. Examination of eye-scan in proximity to selected task events revealed differences in the distribution of looks at the instruments as a function of level of training.
Design of "Eye Closure" system for the stealth of photo-electric equipments
NASA Astrophysics Data System (ADS)
Zhang, Y.; Hua, W. S.; Li, G.
2012-10-01
Based on the optical activity of liquid crystal, a new approach for the stealth of "cat's eye" targets is proposed in this paper. It imitates the physiological close reaction of human eyes when strong light irradiates eyes. With this approach, the "cat's eye" effect will vanish, which is applied in restricting photo-electric equipments being detected and located by active laser detection system. The structure and working principle of the design are presented. The drive circuit is given to control the optical switch automatically. Feasibility of this design is demonstrated by experimental method. The measured data illustrate that the proposed approach is effective to eliminate the "cat's eye" effect, so as to enhancing the viability of photo-electric equipments on the battlefield.
Postural stability changes during large vertical diplopia induced by prism wear in normal subjects.
Matsuo, Toshihiko; Yamasaki, Hanako; Yasuhara, Hirotaka; Hasebe, Kayoko
2013-01-01
To test the effect of double vision on postural stability, we measured postural stability by electric stabilometry before prism-wearing and immediately, 15, 30, and 60min after continuous prism-wearing with 6 prism diopters in total (a 3-prism-diopter prism placed with the base up in front of one eye and with the base down in front of the other eye) in 20 normal adult individuals with their eyes open or closed. Changes in stabilometric parameters in the time course of 60min were analyzed statistically by repeated-measure analysis of variance. When subjectsセ eyes were closed, the total linear length (cm) and the unit-time length (cm/sec) of the sway path were significantly shortened during the 60-minute prism-wearing (p<0.05). No significant change was noted in any stabilometric parameters obtained with the eyes open during the time course. In conclusion, postural stability did not change with the eyes open in the condition of large vertical diplopia, induced by prism-wearing for 60min, while the stability became better when measured with the eyes closed. A postural control mechanism other than that derived from visual input might be reinforced under abnormal visual input such as non-fusionable diplopia.
Eye movements reflect and shape strategies in fraction comparison
Ischebeck, Anja; Weilharter, Marina; Körner, Christof
2016-01-01
The comparison of fractions is a difficult task that can often be facilitated by separately comparing components (numerators and denominators) of the fractions—that is, by applying so-called component-based strategies. The usefulness of such strategies depends on the type of fraction pair to be compared. We investigated the temporal organization and the flexibility of strategy deployment in fraction comparison by evaluating sequences of eye movements in 20 young adults. We found that component-based strategies could account for the response times and the overall number of fixations observed for the different fraction pairs. The analysis of eye movement sequences showed that the initial eye movements in a trial were characterized by stereotypical scanning patterns indicative of an exploratory phase that served to establish the kind of fraction pair presented. Eye movements that followed this phase adapted to the particular type of fraction pair and indicated the deployment of specific comparison strategies. These results demonstrate that participants employ eye movements systematically to support strategy use in fraction comparison. Participants showed a remarkable flexibility to adapt to the most efficient strategy on a trial-by-trial basis. Our results confirm the value of eye movement measurements in the exploration of strategic adaptation in complex tasks. PMID:26039819
Pigmented anatomy in Carboniferous cyclostomes and the evolution of the vertebrate eye.
Gabbott, Sarah E; Donoghue, Philip C J; Sansom, Robert S; Vinther, Jakob; Dolocan, Andrei; Purnell, Mark A
2016-08-17
The success of vertebrates is linked to the evolution of a camera-style eye and sophisticated visual system. In the absence of useful data from fossils, scenarios for evolutionary assembly of the vertebrate eye have been based necessarily on evidence from development, molecular genetics and comparative anatomy in living vertebrates. Unfortunately, steps in the transition from a light-sensitive 'eye spot' in invertebrate chordates to an image-forming camera-style eye in jawed vertebrates are constrained only by hagfish and lampreys (cyclostomes), which are interpreted to reflect either an intermediate or degenerate condition. Here, we report-based on evidence of size, shape, preservation mode and localized occurrence-the presence of melanosomes (pigment-bearing organelles) in fossil cyclostome eyes. Time of flight secondary ion mass spectrometry analyses reveal secondary ions with a relative intensity characteristic of melanin as revealed through principal components analyses. Our data support the hypotheses that extant hagfish eyes are degenerate, not rudimentary, that cyclostomes are monophyletic, and that the ancestral vertebrate had a functional visual system. We also demonstrate integument pigmentation in fossil lampreys, opening up the exciting possibility of investigating colour patterning in Palaeozoic vertebrates. The examples we report add to the record of melanosome preservation in Carboniferous fossils and attest to surprising durability of melanosomes and biomolecular melanin. © 2016 The Authors.
Pigmented anatomy in Carboniferous cyclostomes and the evolution of the vertebrate eye
Gabbott, Sarah E.; Sansom, Robert S.; Vinther, Jakob; Dolocan, Andrei; Purnell, Mark A.
2016-01-01
The success of vertebrates is linked to the evolution of a camera-style eye and sophisticated visual system. In the absence of useful data from fossils, scenarios for evolutionary assembly of the vertebrate eye have been based necessarily on evidence from development, molecular genetics and comparative anatomy in living vertebrates. Unfortunately, steps in the transition from a light-sensitive ‘eye spot’ in invertebrate chordates to an image-forming camera-style eye in jawed vertebrates are constrained only by hagfish and lampreys (cyclostomes), which are interpreted to reflect either an intermediate or degenerate condition. Here, we report—based on evidence of size, shape, preservation mode and localized occurrence—the presence of melanosomes (pigment-bearing organelles) in fossil cyclostome eyes. Time of flight secondary ion mass spectrometry analyses reveal secondary ions with a relative intensity characteristic of melanin as revealed through principal components analyses. Our data support the hypotheses that extant hagfish eyes are degenerate, not rudimentary, that cyclostomes are monophyletic, and that the ancestral vertebrate had a functional visual system. We also demonstrate integument pigmentation in fossil lampreys, opening up the exciting possibility of investigating colour patterning in Palaeozoic vertebrates. The examples we report add to the record of melanosome preservation in Carboniferous fossils and attest to surprising durability of melanosomes and biomolecular melanin. PMID:27488650
Personal identification by eyes.
Marinović, Dunja; Njirić, Sanja; Coklo, Miran; Muzić, Vedrana
2011-09-01
Identification of persons through the eyes is in the field of biometrical science. Many security systems are based on biometric methods of personal identification, to determine whether a person is presenting itself truly. The human eye contains an extremely large number of individual characteristics that make it particularly suitable for the process of identifying a person. Today, the eye is considered to be one of the most reliable body parts for human identification. Systems using iris recognition are among the most secure biometric systems.
Rhodes, Lindsay A; Huisingh, Carrie E; McGwin, Gerald; Mennemeyer, Stephen T; Bregantini, Mary; Patel, Nita; Saaddine, Jinan; Crews, John E; Girkin, Christopher A; Owsley, Cynthia
2016-01-01
To assess the impact of the education program of the Eye Care Quality and Accessibility Improvement in the Community (EQUALITY) telemedicine program on at-risk patients' knowledge about glaucoma and attitudes about eye care as well as to assess patient satisfaction with EQUALITY. New or existing patients presenting for a comprehensive eye exam (CEE) at one of two retail-based primary eye clinics were enrolled based on ≥1 of the following at-risk criteria for glaucoma: African Americans ≥40 years of age, Whites ≥50 years of age, diabetes, family history of glaucoma, and/or preexisting diagnosis of glaucoma. A total of 651 patients were enrolled. A questionnaire was administered prior to the patients' CEE and prior to the patients receiving any of the evidence-based eye health education program; a follow-up questionnaire was administered 2-4 weeks later by phone. Baseline and follow-up patient responses regarding knowledge about glaucoma and attitudes about eye care were compared using McNemar's test. Logistic regression models were used to assess the association of patient-level characteristics with improvement in knowledge and attitudes. Overall patient satisfaction was summarized. At follow-up, all patient responses in the knowledge and attitude domains significantly improved from baseline (P≤0.01 for all questions). Those who were unemployed (odds ratio =0.63, 95% confidence interval =0.42-0.95, P=0.026) or had lower education (odds ratio =0.55, 95% confidence interval =0.29-1.02, P=0.058) were less likely to improve their knowledge after adjusting for age, sex, race, and prior glaucoma diagnosis. This association was attenuated after further adjustment for other patient-level characteristics. Ninety-eight percent (n=501) of patients reported being likely to have a CEE within the next 2 years, whereas 63% (n=326) had a CEE in the previous 2 years. Patient satisfaction with EQUALITY was high (99%). Improved knowledge about glaucoma and a high intent to pursue eye care may lead to improved detection of early disease, thus lowering the risk of blindness.
A PC-based shutter glasses controller for visual stimulation using multithreading in LabWindows/CVI.
Gramatikov, Ivan; Simons, Kurt; Guyton, David; Gramatikov, Boris
2017-05-01
Amblyopia, commonly known as "lazy eye," is poor vision in an eye from prolonged neurologic suppression. It is a major public health problem, afflicting up to 3.6% of children, and will lead to lifelong visual impairment if not identified and treated in early childhood. Traditional treatment methods, such as occluding or penalizing the good eye with eye patches or blurring eye drops, do not always yield satisfactory results. Newer methods have emerged, based on liquid crystal shutter glasses that intermittently occlude the better eye, or alternately occlude the two eyes, thus stimulating vision in the "lazy" eye. As yet there is no technology that allows easy and efficient optimization of the shuttering characteristics for a given individual. The purpose of this study was to develop an inexpensive, computer-based system to perform liquid crystal shuttering in laboratory and clinical settings to help "wake up" the suppressed eye in amblyopic patients, and to help optimize the individual shuttering parameters such as wave shape, level of transparency/opacity, frequency, and duty cycle of the shuttering. We developed a liquid crystal glasses controller connected by USB cable to a PC computer. It generates the voltage waveforms going to the glasses, and has potentiometer knobs for interactive adjustments by the patient. In order to achieve good timing performance in this bidirectional system, we used multithreading programming techniques with data protection, implemented in LabWindows/CVI. The hardware and software developed were assessed experimentally. We achieved an accuracy of ±1Hz for the frequency, and ±2% for the duty cycle of the occlusion pulses. We consider these values to be satisfactory for the purpose of optimizing the visual stimulation by means of shutter glasses. The system can be used for individual optimization of shuttering attributes by clinicians, for training sessions in clinical settings, or even at home, aimed at stimulating vision in the "lazy" eye. Multithreading offers significant benefits for data acquisition and instrument control, making it possible to implement time-efficient algorithms in inexpensive yet versatile medical instrumentation with only minimum requirements on the hardware. Copyright © 2017 Elsevier B.V. All rights reserved.
Mapping and correcting the influence of gaze position on pupil size measurements
Petrov, Alexander A.
2015-01-01
Pupil size is correlated with a wide variety of important cognitive variables and is increasingly being used by cognitive scientists. Pupil data can be recorded inexpensively and non-invasively by many commonly used video-based eye-tracking cameras. Despite the relative ease of data collection and increasing prevalence of pupil data in the cognitive literature, researchers often underestimate the methodological challenges associated with controlling for confounds that can result in misinterpretation of their data. One serious confound that is often not properly controlled is pupil foreshortening error (PFE)—the foreshortening of the pupil image as the eye rotates away from the camera. Here we systematically map PFE using an artificial eye model and then apply a geometric model correction. Three artificial eyes with different fixed pupil sizes were used to systematically measure changes in pupil size as a function of gaze position with a desktop EyeLink 1000 tracker. A grid-based map of pupil measurements was recorded with each artificial eye across three experimental layouts of the eye-tracking camera and display. Large, systematic deviations in pupil size were observed across all nine maps. The measured PFE was corrected by a geometric model that expressed the foreshortening of the pupil area as a function of the cosine of the angle between the eye-to-camera axis and the eye-to-stimulus axis. The model reduced the root mean squared error of pupil measurements by 82.5 % when the model parameters were pre-set to the physical layout dimensions, and by 97.5 % when they were optimized to fit the empirical error surface. PMID:25953668
Chen, Henry Shen-Lih; Liu, Chun-Hsiu; Lu, Da-Wen
2016-01-01
Background/Purpose: To evaluate and compare the diagnostic discriminative ability for detecting glaucoma in highly myopic eyes from a normative database of macular ganglion cell complex (mGCC) thickness based on nonhighly myopic and highly myopic normal eyes. Methods: Forty-nine eyes of 49 participants with high myopia (axial length ≥ 26.0 mm) were enrolled. Spectral-domain optical coherence tomography scans were done using RS-3000, and the mGCC thickness/significance maps within a 9-mm diameter circle were generated using built-in software. We compared the difference of sensitivity, specificity, and diagnostic accuracy between the nonhighly myopic database and the highly myopic database for differentiating the early glaucomatous eyes from the nonglaucomatous eyes. Results: This study enrolled 15 normal eyes and 34 eyes with glaucoma. The mean mGCC thickness of the glaucoma group was significantly less than that of the normal group (p < 0.001). Sensitivity was 96.3%, and the specificity was 50.0% when using the nonhighly myopic normative database. When the highly myopic normative database was used, the sensitivity was 88.9%, and the specificity was 90.0%. The false positive rate was significantly lower when using the highly myopic normative database (p < 0.05). Conclusion: The evaluations of glaucoma in eyes with high myopia using a nonhighly myopic normative database may lead to a frequent misdiagnosis. When evaluating glaucoma in high myopic eyes, the mGCC thickness determined by the long axial length high myopic normative database should be applied. PMID:29018704
ERIC Educational Resources Information Center
Magnussen, Rikke; Zachariassen, Maria; Kharlamov, Nikita; Larsen, Birger
2017-01-01
This paper presents a methodological discussion of the potential and challenges of involving mobile eye tracking technology in studies of knowledge generation and learning in a science centre context. The methodological exploration is based on eye-tracking studies of audience interaction and knowledge generation in the technology-enhanced health…
A Microcomputer-Based Software Package for Eye-Monitoring Research. Technical Report No. 434.
ERIC Educational Resources Information Center
McConkie, George W.; And Others
A software package is described that collects and reduces eye behavior data (eye position and pupil size) using an IBM-PC compatible computer. Written in C language for speed and portability, it includes several features: (1) data can be simultaneously collected from other sources (such as electroencephalography and electromyography); (2)…
Biomimetics and astronomical X-ray optics
NASA Astrophysics Data System (ADS)
Hudec, R.; Remisova, K.
2017-07-01
Some sea and water animals have strange mirror eyes which have (or might have) potential application in science and technology in general and in X—ray astrophysics in particular. While the principles of mirror eyes of decapods (lobsters, crayfishes) are already applied in space and ground—based imaging experiments, the mirror eyes of specific fishes are still very little investigated.
Patty, Lauren; Wu, Cathy; Torres, Mina; Azen, Stanley; Varma, Rohit
2012-09-01
To examine the validity of self-reported eye disease, including cataract, age-related macular degeneration (AMD), glaucoma, and diabetic retinopathy (DR), and self-reported surgical treatment for cataract and DR in the Los Angeles Latino Eye Study (LALES). Population-based, cross-sectional study. A total of 6357 Latinos aged 40+ years from the LALES. Participants underwent a detailed interview, including survey questions about ocular health, diagnoses, and timing of last eye examination, and a standardized clinical examination. Self-report was compared with examination to determine sensitivity and specificity by length of time since last eye examination. Stepwise logistic regression was used to determine factors associated with inaccurate self-report. Sensitivity and specificity were calculated for 4 self-reported eye diseases (cataract, AMD, glaucoma, and DR) and for surgical treatment of cataract and DR. Odds ratios (ORs) were determined for factors associated with inaccurate self-report underestimating eye disease and treatment. For each disease, sensitivity and specificity in those who reported their last eye examination as <1 year ago were 36.8% and 92.5% for cataract, 37.7% and 96.3% for glaucoma, 5.1% and 98.9% for AMD, and 25.7% and 94.2% for DR, respectively. Self-report was less accurate with increasing time since last eye examination. Inaccurate self-report was independently associated with better visual acuity (OR, 2.4), <2 comorbidities (OR, 1.7), last eye examination/visit 1 to 5 years ago and ≥ 5 years ago (OR, 2.3 and 4.9, respectively), and less education (OR, 1.3 for 7-12 years and 1.7 for <7 years). Of 88 participants surgically treated for cataract who reported an eye examination <1 year ago, sensitivity and specificity of self-reported surgical history were 90.9% and 99.9%, respectively. Of the 31 participants treated for DR (laser/surgery) and reporting an eye examination <1 year ago, sensitivity and specificity of self-reported surgical history were 19.4% and 99.6%, respectively. Among Latinos, self-reporting of eye disease and surgical history provides a significant underestimate of the disease burden. This may lead to significant misclassification in vision research if self-report alone is used to identify persons with eye disease. Copyright © 2012 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Patty, Lauren; Wu, Cathy; Torres, Mina; Azen, Stanley; Varma, Rohit
2012-01-01
Purpose To examine the validity of self-reported eye disease, including cataract, age-related macular degeneration (AMD), glaucoma, and diabetic retinopathy (DR), and self-reported surgical treatment for cataract and DR in the Los Angeles Latino Eye Study (LALES). Design Population-based cross-sectional study Participants 6357 Latinos age 40+ years from the LALES Methods Participants underwent a detailed interview, including survey questions about ocular health, diagnoses and timing of last eye examination, and a standardized clinical examination. Self report was compared to examination to determine sensitivity and specificity by length of time since last eye examination. Stepwise logistic regression was used to determine factors associated with inaccurate self report. Main Outcome Measures Sensitivity and specificity were calculated for four self reported eye diseases (cataract, AMD, glaucoma, DR) and for surgical treatment of cataract and DR. Odds ratios (OR) were determined for factors associated with inaccurate self report underestimating eye disease and treatment. Results For each disease, sensitivity and specificity in those who reported their last eye examination as <1 year ago were: 36.8%, 92.5% for cataract; 37.7%, 96.3% for glaucoma; 5.1%, 98.9% for AMD; and 25.7%, 94.2% for DR. Self report was less accurate with increasing time since last eye examination. Inaccurate self report was independently associated with better visual acuity (OR=2.4), <2 comorbidities (OR=1.7), last eye exam/visit 1–5 years ago and ≥5 years ago (OR=2.3 and 4.9, respectively), and less education (OR=1.3 for 7–12 years and 1.7 for <7 years). Of 88 participants surgically treated for cataract who reported an eye examination <1 year ago, sensitivity and specificity of self-reported surgical history were 90.9% and 99.9%. Of the 31 participants treated for DR (laser/surgery) and reporting an eye examination <1 year ago, sensitivity and specificity of self-reported surgical history were 19.4% and 99.6%. Conclusions Among Latinos, self reporting of eye disease and surgical history provides a significant underestimate of the disease burden. This may lead to significant misclassification in vision research if self report alone is used to identify persons with eye disease. PMID:22537615
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rüegsegger, Michael B.; Steiner, Patrick; Kowal, Jens H., E-mail: jens.kowal@artorg.unibe.ch
Purpose: External beam radiation therapy is currently considered the most common treatment modality for intraocular tumors. Localization of the tumor and efficient compensation of tumor misalignment with respect to the radiation beam are crucial. According to the state of the art procedure, localization of the target volume is indirectly performed by the invasive surgical implantation of radiopaque clips or is limited to positioning the head using stereoscopic radiographies. This work represents a proof-of-concept for direct and noninvasive tumor referencing based on anterior eye topography acquired using optical coherence tomography (OCT). Methods: A prototype of a head-mounted device has been developedmore » for automatic monitoring of tumor position and orientation in the isocentric reference frame for LINAC based treatment of intraocular tumors. Noninvasive tumor referencing is performed with six degrees of freedom based on anterior eye topography acquired using OCT and registration of a statistical eye model. The proposed prototype was tested based on enucleated pig eyes and registration accuracy was measured by comparison of the resulting transformation with tilt and torsion angles manually induced using a custom-made test bench. Results: Validation based on 12 enucleated pig eyes revealed an overall average registration error of 0.26 ± 0.08° in 87 ± 0.7 ms for tilting and 0.52 ± 0.03° in 94 ± 1.4 ms for torsion. Furthermore, dependency of sampling density on mean registration error was quantitatively assessed. Conclusions: The tumor referencing method presented in combination with the statistical eye model introduced in the past has the potential to enable noninvasive treatment and may improve quality, efficacy, and flexibility of external beam radiotherapy of intraocular tumors.« less
Reinstein, Dan Z; Lovisolo, Carlo F; Archer, Timothy J; Gobbe, Marine
2013-01-01
To compare vault height predictability of Implantable Collamer Lens (ICL; Staar Surgical) sizing using a sulcus diameter-based formula or the manufacturer-recommended white-to-white-based method. In 50 myopic eyes, ICL size was calculated using both a formula including sulcus diameter and the traditional formula based on white-to-white diameter. Sulcus diameter was measured using Artemis 2 very high-frequency (VHF) digital ultrasound (ArcScan Inc). Implantation was based on the sulcus diameter derived size. Actual postoperative vault height achieved was measured by VHF digital ultrasound scanning. Circle segment trigonometry was used to calculate the vault height that would have resulted had lens sizing been based on the white-to-white formula. The same lens size would have been used in 60% of eyes, a smaller lens would have been used in 34% of eyes and a larger lens in 6% of eyes had lens sizing been based on the white-to-white formula. Mean vault for eyes with lenses sized using the sulcus diameter formula was 0.37±0.16 mm (range: 0.08 to 0.92 mm), with 2% <0.09 mm, the recognized low-vault height for risk of cataract. Circle segment trigonometry predicted that the vault height would have been 0.24±0.28 mm (range: -0.31 to 0.92 mm), with 26% <0.09 mm had lens sizing been based on the white-to-white formula. Significantly better predictability of postoperative vault height was achieved by including sulcus diameter into the ICL sizing formula compared with using the traditional white-to-white-based formula. Copyright 2013, SLACK Incorporated.
The Individual Virtual Eye: a Computer Model for Advanced Intraocular Lens Calculation
Einighammer, Jens; Oltrup, Theo; Bende, Thomas; Jean, Benedikt
2010-01-01
Purpose To describe the individual virtual eye, a computer model of a human eye with respect to its optical properties. It is based on measurements of an individual person and one of its major application is calculating intraocular lenses (IOLs) for cataract surgery. Methods The model is constructed from an eye's geometry, including axial length and topographic measurements of the anterior corneal surface. All optical components of a pseudophakic eye are modeled with computer scientific methods. A spline-based interpolation method efficiently includes data from corneal topographic measurements. The geometrical optical properties, such as the wavefront aberration, are simulated with real ray-tracing using Snell's law. Optical components can be calculated using computer scientific optimization procedures. The geometry of customized aspheric IOLs was calculated for 32 eyes and the resulting wavefront aberration was investigated. Results The more complex the calculated IOL is, the lower the residual wavefront error is. Spherical IOLs are only able to correct for the defocus, while toric IOLs also eliminate astigmatism. Spherical aberration is additionally reduced by aspheric and toric aspheric IOLs. The efficient implementation of time-critical numerical ray-tracing and optimization procedures allows for short calculation times, which may lead to a practicable method integrated in some device. Conclusions The individual virtual eye allows for simulations and calculations regarding geometrical optics for individual persons. This leads to clinical applications like IOL calculation, with the potential to overcome the limitations of those current calculation methods that are based on paraxial optics, exemplary shown by calculating customized aspheric IOLs.
Automatic system for 3D reconstruction of the chick eye based on digital photographs.
Wong, Alexander; Genest, Reno; Chandrashekar, Naveen; Choh, Vivian; Irving, Elizabeth L
2012-01-01
The geometry of anatomical specimens is very complex and accurate 3D reconstruction is important for morphological studies, finite element analysis (FEA) and rapid prototyping. Although magnetic resonance imaging, computed tomography and laser scanners can be used for reconstructing biological structures, the cost of the equipment is fairly high and specialised technicians are required to operate the equipment, making such approaches limiting in terms of accessibility. In this paper, a novel automatic system for 3D surface reconstruction of the chick eye from digital photographs of a serially sectioned specimen is presented as a potential cost-effective and practical alternative. The system is designed to allow for automatic detection of the external surface of the chick eye. Automatic alignment of the photographs is performed using a combination of coloured markers and an algorithm based on complex phase order likelihood that is robust to noise and illumination variations. Automatic segmentation of the external boundaries of the eye from the aligned photographs is performed using a novel level-set segmentation approach based on a complex phase order energy functional. The extracted boundaries are sampled to construct a 3D point cloud, and a combination of Delaunay triangulation and subdivision surfaces is employed to construct the final triangular mesh. Experimental results using digital photographs of the chick eye show that the proposed system is capable of producing accurate 3D reconstructions of the external surface of the eye. The 3D model geometry is similar to a real chick eye and could be used for morphological studies and FEA.
Jiang, Yuzhen; Huang, Wenyong; Huang, Qunxiao; Zhang, Jian; Foster, Paul J.
2010-01-01
Objective. To classify anatomic features related to anterior chamber angles by a qualitative assessment system based on ultrasound biomicroscopy (UBM) images. Methods. Cases of primary angle-closure suspect (PACS), defined by pigmented trabecular meshwork that is not visible in two or more quadrants on static gonioscopy (cases) and systematically selected subjects (1 of every 10) who did not meet this criterion (controls) were enrolled during a population-based survey in Guangzhou, China. All subjects underwent UBM examination. A set of standard UBM images was used to qualitatively classify anatomic features related to the angle configuration, including iris thickness, iris convexity, iris angulation, ciliary body size, and ciliary process position. All analysis was conducted on right eye images. Results. Based on the qualitative grades, the difference in overall iris thickness between gonioscopically narrow eyes (n = 117) and control eyes (n = 57) was not statistically significant. The peripheral one third of the iris tended to be thicker in all quadrants of the PACS eyes, although the difference was statistically significant only in the superior quadrant (P = 0.008). No significant differences were found in the qualitative classifications of iris insertion, iris angulation, ciliary body size, and ciliary process position. The findings were similar when compared with the control group of eyes with wide angles in all quadrants. Conclusions. Basal iris thickness seems to be more relevant to narrow angle configuration than to overall iris thickness. Otherwise, the anterior rotation and size of the ciliary body, the iris insertion, and the overall iris thickness are comparable in narrow- and wide-angle eyes. PMID:19834039
Application of 3-Dimensional Printing Technology to Construct an Eye Model for Fundus Viewing Study
Li, Xinhua; Gao, Zhishan; Yuan, Dongqing; Liu, Qinghuai
2014-01-01
Objective To construct a life-sized eye model using the three-dimensional (3D) printing technology for fundus viewing study of the viewing system. Methods We devised our schematic model eye based on Navarro's eye and redesigned some parameters because of the change of the corneal material and the implantation of intraocular lenses (IOLs). Optical performance of our schematic model eye was compared with Navarro's schematic eye and other two reported physical model eyes using the ZEMAX optical design software. With computer aided design (CAD) software, we designed the 3D digital model of the main structure of the physical model eye, which was used for three-dimensional (3D) printing. Together with the main printed structure, polymethyl methacrylate(PMMA) aspherical cornea, variable iris, and IOLs were assembled to a physical eye model. Angle scale bars were glued from posterior to periphery of the retina. Then we fabricated other three physical models with different states of ammetropia. Optical parameters of these physical eye models were measured to verify the 3D printing accuracy. Results In on-axis calculations, our schematic model eye possessed similar size of spot diagram compared with Navarro's and Bakaraju's model eye, much smaller than Arianpour's model eye. Moreover, the spherical aberration of our schematic eye was much less than other three model eyes. While in off- axis simulation, it possessed a bit higher coma and similar astigmatism, field curvature and distortion. The MTF curves showed that all the model eyes diminished in resolution with increasing field of view, and the diminished tendency of resolution of our physical eye model was similar to the Navarro's eye. The measured parameters of our eye models with different status of ametropia were in line with the theoretical value. Conclusions The schematic eye model we designed can well simulate the optical performance of the human eye, and the fabricated physical one can be used as a tool in fundus range viewing research. PMID:25393277
Application of 3-dimensional printing technology to construct an eye model for fundus viewing study.
Xie, Ping; Hu, Zizhong; Zhang, Xiaojun; Li, Xinhua; Gao, Zhishan; Yuan, Dongqing; Liu, Qinghuai
2014-01-01
To construct a life-sized eye model using the three-dimensional (3D) printing technology for fundus viewing study of the viewing system. We devised our schematic model eye based on Navarro's eye and redesigned some parameters because of the change of the corneal material and the implantation of intraocular lenses (IOLs). Optical performance of our schematic model eye was compared with Navarro's schematic eye and other two reported physical model eyes using the ZEMAX optical design software. With computer aided design (CAD) software, we designed the 3D digital model of the main structure of the physical model eye, which was used for three-dimensional (3D) printing. Together with the main printed structure, polymethyl methacrylate(PMMA) aspherical cornea, variable iris, and IOLs were assembled to a physical eye model. Angle scale bars were glued from posterior to periphery of the retina. Then we fabricated other three physical models with different states of ammetropia. Optical parameters of these physical eye models were measured to verify the 3D printing accuracy. In on-axis calculations, our schematic model eye possessed similar size of spot diagram compared with Navarro's and Bakaraju's model eye, much smaller than Arianpour's model eye. Moreover, the spherical aberration of our schematic eye was much less than other three model eyes. While in off- axis simulation, it possessed a bit higher coma and similar astigmatism, field curvature and distortion. The MTF curves showed that all the model eyes diminished in resolution with increasing field of view, and the diminished tendency of resolution of our physical eye model was similar to the Navarro's eye. The measured parameters of our eye models with different status of ametropia were in line with the theoretical value. The schematic eye model we designed can well simulate the optical performance of the human eye, and the fabricated physical one can be used as a tool in fundus range viewing research.
Automatic emotional expression analysis from eye area
NASA Astrophysics Data System (ADS)
Akkoç, Betül; Arslan, Ahmet
2015-02-01
Eyes play an important role in expressing emotions in nonverbal communication. In the present study, emotional expression classification was performed based on the features that were automatically extracted from the eye area. Fırst, the face area and the eye area were automatically extracted from the captured image. Afterwards, the parameters to be used for the analysis through discrete wavelet transformation were obtained from the eye area. Using these parameters, emotional expression analysis was performed through artificial intelligence techniques. As the result of the experimental studies, 6 universal emotions consisting of expressions of happiness, sadness, surprise, disgust, anger and fear were classified at a success rate of 84% using artificial neural networks.
Modulation transfer function of a fish-eye lens based on the sixth-order wave aberration theory.
Jia, Han; Lu, Lijun; Cao, Yiqing
2018-01-10
A calculation program of the modulation transfer function (MTF) of a fish-eye lens is developed with the autocorrelation method, in which the sixth-order wave aberration theory of ultra-wide-angle optical systems is used to simulate the wave aberration distribution at the exit pupil of the optical systems. The autocorrelation integral is processed with the Gauss-Legendre integral, and the magnification chromatic aberration is discussed to calculate polychromatic MTF. The MTF calculation results of a given example are then compared with those previously obtained based on the fourth-order wave aberration theory of plane-symmetrical optical systems and with those from the Zemax program. The study shows that MTF based on the sixth-order wave aberration theory has satisfactory calculation accuracy even for a fish-eye lens with a large acceptance aperture. And the impacts of different types of aberrations on the MTF of a fish-eye lens are analyzed. Finally, we apply the self-adaptive and normalized real-coded genetic algorithm and the MTF developed in the paper to optimize the Nikon F/2.8 fish-eye lens; consequently, the optimized system shows better MTF performances than those of the original design.
Structure and function of a compound eye, more than half a billion years old.
Schoenemann, Brigitte; Pärnaste, Helje; Clarkson, Euan N K
2017-12-19
Until now, the fossil record has not been capable of revealing any details of the mechanisms of complex vision at the beginning of metazoan evolution. Here, we describe functional units, at a cellular level, of a compound eye from the base of the Cambrian, more than half a billion years old. Remains of early Cambrian arthropods showed the external lattices of enormous compound eyes, but not the internal structures or anything about how those compound eyes may have functioned. In a phosphatized trilobite eye from the lower Cambrian of the Baltic, we found lithified remnants of cellular systems, typical of a modern focal apposition eye, similar to those of a bee or dragonfly. This shows that sophisticated eyes already existed at the beginning of the fossil record of higher organisms, while the differences between the ancient system and the internal structures of a modern apposition compound eye open important insights into the evolution of vision. Copyright © 2017 the Author(s). Published by PNAS.
Neural bases of eye and gaze processing: The core of social cognition
Itier, Roxane J.; Batty, Magali
2014-01-01
Eyes and gaze are very important stimuli for human social interactions. Recent studies suggest that impairments in recognizing face identity, facial emotions or in inferring attention and intentions of others could be linked to difficulties in extracting the relevant information from the eye region including gaze direction. In this review, we address the central role of eyes and gaze in social cognition. We start with behavioral data demonstrating the importance of the eye region and the impact of gaze on the most significant aspects of face processing. We review neuropsychological cases and data from various imaging techniques such as fMRI/PET and ERP/MEG, in an attempt to best describe the spatio-temporal networks underlying these processes. The existence of a neuronal eye detector mechanism is discussed as well as the links between eye gaze and social cognition impairments in autism. We suggest impairments in processing eyes and gaze may represent a core deficiency in several other brain pathologies and may be central to abnormal social cognition. PMID:19428496
Frequency and seasonal variation of ophthalmology-related internet searches.
Leffler, Christopher T; Davenport, Byrd; Chan, Dana
2010-06-01
To use internet search activity to reveal the intensity of public interest and seasonal variation in ophthalmology-related diseases, symptoms, and treatments. Time-series analysis of internet search data. Google trend data for ophthalmology terms for the United States, the United Kingdom, Canada, and Australia from 2004 through 2008 were studied. Mean population-weighted temperature and fraction of schools in session were estimated from databases, and relative potential sunlight intensity was calculated. Multivariable linear regression was used to predict search term frequency based on environmental variables. Relative to diabetes searches (100%), common US eye-related searches were: "glasses" (44%), "Lasik" (16%), "contact lenses" (12.4%), "pink eye" (9.5%), "glaucoma" (5.9%), "cataract" (4.1%), "dry eyes" (2.1%), "eye twitching" (1.9%), and "eye pain" (1.9%). Seasonal nature was high for "conjunctivitis" (r(2) = 0.37), "pink eye" (r(2) = 0.32), "eye floaters" (r2 = 0.26), and "stye" (r(2) = 0.19), moderate for "glaucoma" (r(2) = 0.09) and "eye twitching" (r(2) = 0.06), and low for "uveitis" (r(2) = 0.02) and "macular degeneration" (r(2) < 0.01). Heat was associated with "stye" and cold was associated with "pink eye," "conjunctivitis," and "glaucoma" (all p < 0.002). Sunlight intensity was associated with "dry eyes" and "eye floaters" (p < 0.01). School sessions were associated positively with "eye twitching" (p >= 0.001) and negatively with "eyeglasses." "Eye allergy," "itchy eyes," and "watery eyes" were highly seasonal (r(2) = 0.75-0.38) and associated with "pollen" searches. Internet ophthalmology searches relate (in decreasing order) to refractive correction, eye diseases, and eye symptoms. Search study reveals the seasonality and environmental associations of interest in health terms.
Domienik, J; Farah, J; Struelens, L
2016-12-01
The first validation results of the two approaches developed in the ELDO project for retrospective assessment of eye lens doses for interventional cardiologists (ICs) are presented in this paper. The first approach (a) is based on both the readings from the routine whole body dosimeter worn above the lead apron and procedure-dependent conversion coefficients, while the second approach (b) is based on detailed information related to the occupational exposure history of the ICs declared in a questionnaire and eye lens dose records obtained from the relevant literature. The latter approach makes use of various published eye lens doses per procedure as well as the appropriate correction factors which account for the use of radiation protective tools designed to protect the eye lens. To validate both methodologies, comprehensive measurements were performed in several Polish clinics among recruited physicians. Two dosimeters measuring whole body and eye lens doses were worn by every physician for at least two months. The estimated cumulative eye lens doses, calculated from both approaches, were then compared against the measured eye lens dose value for every physician separately. Both approaches results in comparable estimates of eye lens doses and tend to overestimate rather than underestimate the eye lens doses. The measured and estimated doses do not differ, on average, by a factor higher than 2.0 in 85% and 62% of the cases used to validate approach (a) and (b), respectively. In specific cases, however, the estimated doses differ from the measured ones by as much as a factor of 2.7 and 5.1 for method (a) and (b), respectively. As such, the two approaches can be considered accurate when retrospectively estimating the eye lens doses for ICs and will be of great benefit for ongoing epidemiological studies.
Ito, Mitsutoshi; Arai, Hiroyuki; Fukumoto, Teruki; Toda, Ikuko; Tsubota, Kazuo
2004-01-01
Intrastromal corneal ring segments (INTACS Micro-Thin Prescription Inserts by Addition Technologies, Fremont, Calif) were inserted as a combined surgery with laser in situ keratomileusis (LASIK) in six eyes with thin corneas to correct moderately high myopia. INTACS were implanted before LASIK (INTACS-LASIK) in three eyes and after LASIK (LASIK-INTACS) in three eyes. Mean preoperative manifest spherical equivalent refraction was -7.88 diopters. Mean follow-up was 306 days. No intraoperative complications occurred. The LASIK-INTACS eyes were slightly more overcorrected than the INTACS-LASIK eyes because of the enhanced performance of INTACS in the thinned corneal tissue. Induced astigmatism by INTACS per se was less in the LASIK-INTACS eyes than in the INTACS-LASIK eyes. At last examination, uncorrected visual acuity was better than 20/25 in all eyes. Best spectacle-corrected visual acuity was within 1 line of the preoperative value in all eyes. Both methods resulted in significant improvement in visual acuity and refraction. Based on our limited experience, however, LASIK followed by INTACS is preferred for reasons of safety, convenience, and lower induced cylinder.
[Myelinated nerve fibers coexisted with epiretinal membrane in macula--case report].
Swiech-Zubilewicz, Anna; Bieliński, Paweł; Dolar-Szczasny, Joanna; Zarnowski, Tomasz
2012-01-01
We describe a case of peripapillary myelinated retinal nerve fibers complicated by epiretinal membrane in region of macula. 72 years old man was refered to our Clinic with suspicion of retinal detachment of right eye. Visual acuity of right eye was based to 0.05, in left eye was 0.5. IOP was normal in both eyes. In biomcroscopic evaluation the slight cortical cataract was observed in both eyes. Stereoscopic evaluation of right eye revealed the presence of massive peripapillary myelinated retinal nerve fibers and epiretinal membrane in the macula. In the left eye the less intense peripapillary myelinated retinal nerve fibers were noticed as well and the macular region was unchanged. With the use of OCT examination of the retina the presence of epiretinal membrane in the right eye was confirmed. OCT in the fellow eye presented an undisturbed foveal profile without any epiretinal abnormalities. Myelinated retinal nerve fibers can be complicated by epiretinal membrane. Probably the presence of macular pathologies depends on the extensions of nerve fibers. OCT examination is very helpful to give a proper diagnosis.
Chang, Won-Du; Cha, Ho-Seung; Im, Chang-Hwan
2016-01-01
This paper introduces a method to remove the unwanted interdependency between vertical and horizontal eye-movement components in electrooculograms (EOGs). EOGs have been widely used to estimate eye movements without a camera in a variety of human-computer interaction (HCI) applications using pairs of electrodes generally attached either above and below the eye (vertical EOG) or to the left and right of the eyes (horizontal EOG). It has been well documented that the vertical EOG component has less stability than the horizontal EOG one, making accurate estimation of the vertical location of the eyes difficult. To address this issue, an experiment was designed in which ten subjects participated. Visual inspection of the recorded EOG signals showed that the vertical EOG component is highly influenced by horizontal eye movements, whereas the horizontal EOG is rarely affected by vertical eye movements. Moreover, the results showed that this interdependency could be effectively removed by introducing an individual constant value. It is therefore expected that the proposed method can enhance the overall performance of practical EOG-based eye-tracking systems. PMID:26907271
Improving data retention in EEG research with children using child-centered eye tracking
Maguire, Mandy J.; Magnon, Grant; Fitzhugh, Anna E.
2014-01-01
Background Event Related Potentials (ERPs) elicited by visual stimuli have increased our understanding of developmental disorders and adult cognitive abilities for decades; however, these studies are very difficult with populations who cannot sustain visual attention such as infants and young children. Current methods for studying such populations include requiring a button response, which may be impossible for some participants, and experimenter monitoring, which is subject to error, highly variable, and spatially imprecise. New Method We developed a child-centered methodology to integrate EEG data acquisition and eye-tracking technologies that uses “attention-getters” in which stimulus display is contingent upon the child’s gaze. The goal was to increase the number of trials retained. Additionally, we used the eye-tracker to categorize and analyze the EEG data based on gaze to specific areas of the visual display, compared to analyzing based on stimulus presentation. Results Compared with Existing Methods The number of trials retained was substantially improved using the child-centered methodology compared to a button-press response in 7–8 year olds. In contrast, analyzing the EEG based on eye gaze to specific points within the visual display as opposed to stimulus presentation provided too few trials for reliable interpretation. Conclusions By using the linked EEG-eye-tracker we significantly increased data retention. With this method, studies can be completed with fewer participants and a wider range of populations. However, caution should be used when epoching based on participants’ eye gaze because, in this case, this technique provided substantially fewer trials. PMID:25251555
NASA Astrophysics Data System (ADS)
Yuan, Yuan; Fang, Tao; Sun, Min Yuan; Gao, Wei Nan; Zhang, Shuo; Bi, Yong
2018-07-01
Laser speckle is a major issue for laser projection displays. In various techniques of speckle reduction, speckle is quantified with a speckle contrast value. However, the measured speckle contrast is poorly suited for the subjective speckle perception of a human observer. Here, we investigate the characteristics of human eyes and propose a simplified optical transfer function of human eyes. Accordingly, two human-eye-modeled speckle measuring sets are configured. Based on the experimental set, an advanced electromagnetic micro-scanning mirror (EM-MSM) is exploited; which is of 6.5 mm in diameter and its half angle is 7.8° for a horizontal scan and 6.53° for a vertical scan. Finally, we quantitatively show that images generated with an EM-MSM exhibit superior quality. By providing human-eye-modeled speckle measuring instruments and an EM-MSM for speckle reduction, it has a promising promotion to laser projector development.
Eye gaze correction with stereovision for video-teleconferencing.
Yang, Ruigang; Zhang, Zhengyou
2004-07-01
The lack of eye contact in desktop video teleconferencing substantially reduces the effectiveness of video contents. While expensive and bulky hardware is available on the market to correct eye gaze, researchers have been trying to provide a practical software-based solution to bring video-teleconferencing one step closer to the mass market. This paper presents a novel approach: Based on stereo analysis combined with rich domain knowledge (a personalized face model), we synthesize, using graphics hardware, a virtual video that maintains eye contact. A 3D stereo head tracker with a personalized face model is used to compute initial correspondences across two views. More correspondences are then added through template and feature matching. Finally, all the correspondence information is fused together for view synthesis using view morphing techniques. The combined methods greatly enhance the accuracy and robustness of the synthesized views. Our current system is able to generate an eye-gaze corrected video stream at five frames per second on a commodity 1 GHz PC.
Lalu, Lida; Tambe, Vishakha; Pradhan, Deepak; Nayak, Kritika; Bagchi, Suchandra; Maheshwari, Rahul; Kalia, Kiran; Tekade, Rakesh Kumar
2017-12-28
Ocular discomforts involve anterior/posterior-segment diseases, symptomatic distress and associated inflammations and severe retinal disorders. Conventionally, the formulations such as eye drops, eye solutions, eye ointments and lotions, etc. were used as modalities to attain relief from such ocular discomforts. However, eye allows limited access to these traditional formulations due to its unique anatomical structure and dynamic ocular environment and therefore calls for improvement in disease intervention. To address these challenges, development of nanotechnology based nanomedicines and novel nanosystems (liposomes, cubosomes, polymeric and lipidic nanoparticles, nanoemulsions, spanlastics and nano micelles) are currently in progress (some of them are already marketed such as Eye-logic liposomal eye spray@Naturalife, Ireland). Today, it is one of the central concept in designing more accessible formulations for deeper segments of the eyes. These nanosystems has largely enabled the availability of medicaments at required site in a required concentration without inversely affecting the eye tissues; and therefore, attaining the excessive considerations from the formulation scientists and pharmacologists worldwide. The entrapment of drugs, genes, and proteins inside these novel systems is the basis that works at the bio-molecular level bestows greater potential to eradicate disease causatives. In this review, we highlighted the recent attempts of nanotechnology-based systems for treating and managing various ocular ailments. The progress described herein may pave the way to new, highly effective and vital ocular nanosystems. Copyright © 2017. Published by Elsevier B.V.
Optical properties of the mouse eye
Geng, Ying; Schery, Lee Anne; Sharma, Robin; Dubra, Alfredo; Ahmad, Kamran; Libby, Richard T.; Williams, David R.
2011-01-01
The Shack-Hartmann wavefront sensor (SHWS) spots upon which ocular aberration measurements depend have poor quality in mice due to light reflected from multiple retinal layers. We have designed and implemented a SHWS that can favor light from a specific retinal layer and measured monochromatic aberrations in 20 eyes from 10 anesthetized C57BL/6J mice. Using this instrument, we show that mice are myopic, not hyperopic as is frequently reported. We have also measured longitudinal chromatic aberration (LCA) of the mouse eye and found that it follows predictions of the water-filled schematic mouse eye. Results indicate that the optical quality of the mouse eye assessed by measurement of its aberrations is remarkably good, better for retinal imaging than the human eye. The dilated mouse eye has a much larger numerical aperture (NA) than that of the dilated human eye (0.5 NA vs. 0.2 NA), but it has a similar amount of root mean square (RMS) higher order aberrations compared to the dilated human eye. These measurements predict that adaptive optics based on this method of wavefront sensing will provide improvements in retinal image quality and potentially two times higher lateral resolution than that in the human eye. PMID:21483598
Neural mechanisms of eye contact when listening to another person talking
Borowiak, Kamila; Tudge, Luke; Otto, Carolin; von Kriegstein, Katharina
2017-01-01
Abstract Eye contact occurs frequently and voluntarily during face-to-face verbal communication. However, the neural mechanisms underlying eye contact when it is accompanied by spoken language remain unexplored to date. Here we used a novel approach, fixation-based event-related functional magnetic resonance imaging (fMRI), to simulate the listener making eye contact with a speaker during verbal communication. Participants’ eye movements and fMRI data were recorded simultaneously while they were freely viewing a pre-recorded speaker talking. The eye tracking data were then used to define events for the fMRI analyses. The results showed that eye contact in contrast to mouth fixation involved visual cortical areas (cuneus, calcarine sulcus), brain regions related to theory of mind/intentionality processing (temporoparietal junction, posterior superior temporal sulcus, medial prefrontal cortex) and the dorsolateral prefrontal cortex. In addition, increased effective connectivity was found between these regions for eye contact in contrast to mouth fixations. The results provide first evidence for neural mechanisms underlying eye contact when watching and listening to another person talking. The network we found might be well suited for processing the intentions of communication partners during eye contact in verbal communication. PMID:27576745
Visualization of semantic relations in geosicences
NASA Astrophysics Data System (ADS)
Ritschel, Bernd; Pfeiffer, Sabine; Mende, Vivien
2010-05-01
The discovery of semantic relations related to the content and context of scientific geophysical and geodetic data and information is a fundamental concept for an integrated scientific approach for the research of multidisciplinary and complex questions of the permanent changing Earth system. Large high-quality and multi-domain geosciences datasets which are qualified by significant and standardized metadata describing the content and especially the context of the data are suitable for the search and discovery of semantic relations. Nowadays such data collections are ingested and provided by many national and international geoscientific data centers, such as e.g. the GFZ ISDC(1). Beside automatic and machine-based algorithm for the discovery of semantic relations, the graphical visualization of such relations are extremely capable for scientist in order to analyze complex datasets and to find sophisticated relations as well as for the public in order to understand the relations within geosciences and between geosciences and societal domains. There are different tools for the visualization of relations, especially in the object-oriented based analysis and development of systems and software. The tool eyePlorer(2) is an awarded program for the visualization of multi-domain semantic relations in the public world of Wikipedia. The data and information for the visualization of keyword based terms and concepts within one domain or topic as well as the relations to other topics are mainly based on wiki content and appropriate structures. eyePlorer's main topics structured and combined in super topics are Health, Species and Life Sciences, Persons and Organisations, Work and Society, Science & Technology as well as Time and Places. Considering the domains or topics of the conceptual model of the GFZ ISDC's data collection, such topics as geosciences-related project, platform, instrument, product type, publication and institution as well as space and time are disjunct and complement sets or subsets or intersections of eyePlorer's topics. The introduction of new topics and the enhancement of the conceptual data model of the eyePlorer as well as the transformation of GFZ ISDC's metadata into a wiki structure or into eyePlorer's internal data format are necessary for the use in eyePlorer for the visualization of geosciences and societal relations based on both, the Wikipedia information collection and the GFZ ISDC metadata. This paper deals with the analysis of eyePlorer's and GFZ ISDC's concepts for the creation of an integrated conceptual model. Furthermore, the transformation model for the conversion of ISDC's metadata into appropriate structures for the use of eyePlorer is described. Finally, the process of semantic visualization of geosciences and societal relations within eyePlorer and using eyePlorer's GUI are illustrated on a climate research related example which is capable to generate knowledge not only for geoscientists but also for the public. (1) GFZ ISDC: GFZ Information System and Data Center, http://isdc.gfz-potsdam.de (2) eyePlorer: http://en.eyeplorer.com/show/
Angle assessment by EyeCam, goniophotography, and gonioscopy.
Baskaran, Mani; Perera, Shamira A; Nongpiur, Monisha E; Tun, Tin A; Park, Judy; Kumar, Rajesh S; Friedman, David S; Aung, Tin
2012-09-01
To compare EyeCam (Clarity Medical Systems, Pleasanton, CA) and goniophotography in detecting angle closure, using gonioscopy as the reference standard. In this hospital-based, prospective, cross-sectional study, participants underwent gonioscopy by a single observer, and EyeCam imaging and goniophotography by different operators. The anterior chamber angle in a quadrant was classified as closed if the posterior trabecular meshwork could not be seen. A masked observer categorized the eyes as per the number of closed quadrants, and an eye was classified as having angle closure if there were 2 or more quadrants of closure. Agreement between the methods was analyzed by κ statistic and comparison of area under receiver operating characteristic curves (AUC). Eighty-five participants (85 eyes) were included, the majority of whom were Chinese. Angle closure was detected in 38 eyes (45%) with gonioscopy, 40 eyes (47%) using EyeCam, and 40 eyes (47%) with goniophotography (P=0.69 in both comparisons, McNemar test). The agreement for angle closure diagnosis (by eye) between gonioscopy and the 2 imaging modalities was high (κ=0.86; 95% Confidence Interval (CI), 0.75-0.97), whereas the agreement between EyeCam and goniophotography was not as good (κ=0.72; 95% CI, 0.57-0.87); largely due to lack of agreement in the nasal and temporal quadrants (κ=0.55 to 0.67). The AUC for detecting eyes with gonioscopic angle closure was similar for goniophotography and EyeCam (AUC 0.93, sensitivity=94.7%, specificity=91.5%; P>0.95). EyeCam and goniophotography have similarly high sensitivity and specificity for the detection of gonioscopic angle closure.
Discriminating anisometropic amblyopia from myopia based on interocular inhibition
Jia, Wuli; Zhou, Jiawei; Lu, Zhong-Lin; Lesmes, Luis A.; Huang, Chang-Bing
2016-01-01
Amblyopia screening during childhood is critical for early detection and successful treatment. In the current study, we develop and evaluate a screening method that exploits the imbalanced interocular inhibition between amblyopic and fellow eyes. In nineteen subjects with anisometropic amblyopia and twenty-two age-matched subjects with myopia, we measured the area under the contrast sensitivity functions (AUCSFs) in eight monocular conditions defined by tested eye (left, right), patching of the untested eye (translucent, opaque), and refractive status (corrected, uncorrected). For each test eye, we defined the inhibition index as the ratio between AUCSF values obtained in the translucent and opaque patching conditions of the untested eye. To evaluate the screening potential of the inhibition index, we compared results from patients with amblyopia and myopia. With and without optical correction, the index was significantly lower in the amblyopic eye than in the fellow eye of the amblyopic subjects and both eyes of the myopic subjects. No significant difference was found among the two eyes of the myopic subjects and the fellow eyes of the amblyopic subjects. With the inhibition index as the predictor, a logistic regression model successfully discriminated amblyopic eyes from myopic eyes with 100% accuracy in the uncorrected condition. In the corrected condition, with the inhibition index and interocular visual acuity difference as predictors, amblyopic eyes were likewise discriminated from myopic eyes with 100% accuracy. This pattern of CSF changes, caused by the different patching modes of the untested eye, provides a potential CSF signature to discriminate anisometropic amblyopia from myopia. PMID:25701741
Neely, David; Zarubina, Anna V; Clark, Mark E; Huisingh, Carrie E; Jackson, Gregory R; Zhang, Yuhua; McGwin, Gerald; Curcio, Christine A; Owsley, Cynthia
2017-07-01
To examine the association between subretinal drusenoid deposits (SDDs) identified by multimodal retinal imaging and visual function in older eyes with normal macular health or in the earliest phases of age-related macular degeneration (AMD). Age-related macular degeneration status for each eye was defined according to the Age-Related Eye Disease Study (AREDS) 9-step classification system (normal = Step 1, early AMD = Steps 2-4) based on color fundus photographs. Visual functions measured were best-corrected photopic visual acuity, contrast and light sensitivity, mesopic visual acuity, low-luminance deficit, and rod-mediated dark adaptation. Subretinal drusenoid deposits were identified through multimodal imaging (color fundus photographs, infrared reflectance and fundus autofluorescence images, and spectral domain optical coherence tomography). The sample included 1,202 eyes (958 eyes with normal health and 244 eyes with early AMD). In normal eyes, SDDs were not associated with any visual function evaluated. In eyes with early AMD, dark adaptation was markedly delayed in eyes with SDDs versus no SDD (a 4-minute delay on average), P = 0.0213. However, this association diminished after age adjustment, P = 0.2645. Other visual functions in early AMD eyes were not associated with SDDs. In a study specifically focused on eyes in normal macular health and in the earliest phases of AMD, early AMD eyes with SDDs have slower dark adaptation, largely attributable to the older ages of eyes with SDD; they did not exhibit deficits in other visual functions. Subretinal drusenoid deposits in older eyes in normal macular health are not associated with any visual functions evaluated.
Video-Based Eye Tracking to Detect the Attention Shift: A Computer Classroom Context-Aware System
ERIC Educational Resources Information Center
Kuo, Yung-Lung; Lee, Jiann-Shu; Hsieh, Min-Chai
2014-01-01
Eye and head movements evoked in response to obvious visual attention shifts. However, there has been little progress on the causes of absent-mindedness so far. The paper proposes an attention awareness system that captures the conditions regarding the interaction of eye gaze and head pose under various attentional switching in computer classroom.…
Visual Data Mining: An Exploratory Approach to Analyzing Temporal Patterns of Eye Movements
ERIC Educational Resources Information Center
Yu, Chen; Yurovsky, Daniel; Xu, Tian
2012-01-01
Infant eye movements are an important behavioral resource to understand early human development and learning. But the complexity and amount of gaze data recorded from state-of-the-art eye-tracking systems also pose a challenge: how does one make sense of such dense data? Toward this goal, this article describes an interactive approach based on…
ERIC Educational Resources Information Center
Hobday, Karen; Ramke, Jacqueline; du Toit, Rènée; Pereira, Sara M.
2015-01-01
Objective: To assess whether there was an improvement in the knowledge, attitudes and practices of students after the Healthy Eyes in Schools Project intervention and to complete a process evaluation to inform future implementation of health promotion interventions. Design: A descriptive, mixed-methods design was used, including questionnaires and…
Prior Knowledge and Online Inquiry-Based Science Reading: Evidence from Eye Tracking
ERIC Educational Resources Information Center
Ho, Hsin Ning Jessie; Tsai, Meng-Jung; Wang, Ching-Yeh; Tsai, Chin-Chung
2014-01-01
This study employed eye-tracking technology to examine how students with different levels of prior knowledge process text and data diagrams when reading a web-based scientific report. Students' visual behaviors were tracked and recorded when they read a report demonstrating the relationship between the greenhouse effect and global climate…
Eye movement analysis for activity recognition using electrooculography.
Bulling, Andreas; Ward, Jamie A; Gellersen, Hans; Tröster, Gerhard
2011-04-01
In this work, we investigate eye movement analysis as a new sensing modality for activity recognition. Eye movement data were recorded using an electrooculography (EOG) system. We first describe and evaluate algorithms for detecting three eye movement characteristics from EOG signals-saccades, fixations, and blinks-and propose a method for assessing repetitive patterns of eye movements. We then devise 90 different features based on these characteristics and select a subset of them using minimum redundancy maximum relevance (mRMR) feature selection. We validate the method using an eight participant study in an office environment using an example set of five activity classes: copying a text, reading a printed paper, taking handwritten notes, watching a video, and browsing the Web. We also include periods with no specific activity (the NULL class). Using a support vector machine (SVM) classifier and person-independent (leave-one-person-out) training, we obtain an average precision of 76.1 percent and recall of 70.5 percent over all classes and participants. The work demonstrates the promise of eye-based activity recognition (EAR) and opens up discussion on the wider applicability of EAR to other activities that are difficult, or even impossible, to detect using common sensing modalities.
Eye gaze tracking based on the shape of pupil image
NASA Astrophysics Data System (ADS)
Wang, Rui; Qiu, Jian; Luo, Kaiqing; Peng, Li; Han, Peng
2018-01-01
Eye tracker is an important instrument for research in psychology, widely used in attention, visual perception, reading and other fields of research. Because of its potential function in human-computer interaction, the eye gaze tracking has already been a topic of research in many fields over the last decades. Nowadays, with the development of technology, non-intrusive methods are more and more welcomed. In this paper, we will present a method based on the shape of pupil image to estimate the gaze point of human eyes without any other intrusive devices such as a hat, a pair of glasses and so on. After using the ellipse fitting algorithm to deal with the pupil image we get, we can determine the direction of the fixation by the shape of the pupil.The innovative aspect of this method is to utilize the new idea of the shape of the pupil so that we can avoid much complicated algorithm. The performance proposed is very helpful for the study of eye gaze tracking, which just needs one camera without infrared light to know the changes in the shape of the pupil to determine the direction of the eye gazing, no additional condition is required.
Gold, Jeffrey Allen; Stephenson, Laurel E; Gorsuch, Adriel; Parthasarathy, Keshav; Mohan, Vishnu
2016-09-01
Numerous reports describe unintended consequences of electronic health record implementation. Having previously described physicians' failures to recognize patient safety issues within our electronic health record simulation environment, we now report on our use of eye and screen-tracking technology to understand factors associated with poor error recognition during an intensive care unit-based electronic health record simulation. We linked performance on the simulation to standard eye and screen-tracking readouts including number of fixations, saccades, mouse clicks and screens visited. In addition, we developed an overall Composite Eye Tracking score which measured when, where and how often each safety item was viewed. For 39 participants, the Composite Eye Tracking score correlated with performance on the simulation (p = 0.004). Overall, the improved performance was associated with a pattern of rapid scanning of data manifested by increased number of screens visited (p = 0.001), mouse clicks (p = 0.03) and saccades (p = 0.004). Eye tracking can be successfully integrated into electronic health record-based simulation and provides a surrogate measure of cognitive decision making and electronic health record usability. © The Author(s) 2015.
Murakami, Yohko; Wang, Dandan; Burkemper, Bruce; Lin, Shan C.; Varma, Rohit
2016-01-01
Purpose To compare grading of goniophotographic images and gonioscopy in assessing the iridocorneal angle. Methods In a population-based, cross-sectional study, participants underwent gonioscopy and goniophotographic imaging during the same visit. The iridocorneal angle was classified as closed if the posterior trabecular meshwork could not be seen. A single masked observer graded the goniophotographic images, and each eye was classified as having angle closure based on the number of closed quadrants. Agreement between the methods was analyzed by calculating kappa (κ) and first-order agreement coefficient (AC1) statistics and comparison of area under receiver operating characteristic curves (AUC). Results A total of 4149 Chinese Americans (3994 eyes) were included in this study. The agreement for angle closure diagnosis between gonioscopy and EyeCam was moderate to excellent (κ = 0.60, AC1 0.90, AUC 0.76–0.80). Conclusions Detection of iridocorneal angle closure based on goniophotographic imaging shows moderate to very good agreement with angle closure assessment using gonioscopy. PMID:27571018
Adriaens, Els; Barroso, João; Eskes, Chantra; Hoffmann, Sebastian; McNamee, Pauline; Alépée, Nathalie; Bessou-Touya, Sandrine; De Smedt, Ann; De Wever, Bart; Pfannenbecker, Uwe; Tailhardat, Magalie; Zuang, Valérie
2014-03-01
For more than two decades, scientists have been trying to replace the regulatory in vivo Draize eye test by in vitro methods, but so far only partial replacement has been achieved. In order to better understand the reasons for this, historical in vivo rabbit data were analysed in detail and resampled with the purpose of (1) revealing which of the in vivo endpoints are most important in driving United Nations Globally Harmonized System/European Union Regulation on Classification, Labelling and Packaging (UN GHS/EU CLP) classification for serious eye damage/eye irritation and (2) evaluating the method's within-test variability for proposing acceptable and justifiable target values of sensitivity and specificity for alternative methods and their combinations in testing strategies. Among the Cat 1 chemicals evaluated, 36-65 % (depending on the database) were classified based only on persistence of effects, with the remaining being classified mostly based on severe corneal effects. Iritis was found to rarely drive the classification (<4 % of both Cat 1 and Cat 2 chemicals). The two most important endpoints driving Cat 2 classification are conjunctiva redness (75-81 %) and corneal opacity (54-75 %). The resampling analyses demonstrated an overall probability of at least 11 % that chemicals classified as Cat 1 by the Draize eye test could be equally identified as Cat 2 and of about 12 % for Cat 2 chemicals to be equally identified as No Cat. On the other hand, the over-classification error for No Cat and Cat 2 was negligible (<1 %), which strongly suggests a high over-predictive power of the Draize eye test. Moreover, our analyses of the classification drivers suggest a critical revision of the UN GHS/EU CLP decision criteria for the classification of chemicals based on Draize eye test data, in particular Cat 1 based only on persistence of conjunctiva effects or corneal opacity scores of 4. In order to successfully replace the regulatory in vivo Draize eye test, it will be important to recognise these uncertainties and to have in vitro tools to address the most important in vivo endpoints identified in this paper.
Beston, Shannon M; Wostl, Elijah; Walsh, Matthew R
2017-08-01
Vertebrates exhibit substantial variation in eye size. Eye size correlates positively with visual capacity and behaviors that enhance fitness, such as predator avoidance. This foreshadows a connection between predation and eye size evolution. Yet, the conditions that favor evolutionary shifts in eye size, besides the well-known role for light availability, are unclear. We tested the influence of predation on the evolution of eye size in Trinidadian killifish, Rivulus hartii. Rivulus are located across a series of communities where they coexist with visually oriented piscivores ("high predation" sites), and no predators ("Rivulus-only" sites). Wild-caught Rivulus from high predation sites generally exhibited a smaller relative eye size than communities that lack predators. Yet, such differences were inconsistent across rivers. Second-generation common garden reared fish revealed repeatable decreases in eye size in Rivulus from high predation sites. We performed additional experiments that tested the importance of light and resources on eye size evolution. Sites that differ in light or resource availability did not differ in eye size. Our results argue that differences in predator-induced mortality underlie genetically-based shifts in vertebrate eye size. We discuss the drivers of eye size evolution in light of the nonparallel trends between the phenotypic and common garden results. © 2017 The Author(s). Evolution © 2017 The Society for the Study of Evolution.
Eye Injury Prevention for the Pediatric Population.
Hoskin, Annette K; Philip, Swetha S; Yardley, Anne-Marie E; Mackey, David A
2016-05-01
Each year an estimated 3.3 to 5.7 million pediatric eye injuries occur worldwide. It is widely reported that 90% of ocular injuries are preventable. Our aim was to identify legislation and policies, education, and mandatory eye protection strategies that have successfully contributed to reducing rates of children's eye injuries. A literature search was conducted using the terms "pediatric" or "children" or "adolescent" and "ocular" or "eye" and "protection" or "injury prevention." Articles were retrieved based on titles and abstracts and assessed in the context of our research question. Strategies identified aimed at reducing ocular trauma fell into 3 broad categories: legislation and policies, education, and personal eye protection. Policies including restrictions on the sale and supply of certain consumer products, mandatory vehicle seatbelts, and laminated windscreens in vehicles have assisted in reducing children's eye injuries. Educational tools aimed at children and their caregivers have been effective in changing attitudes to eye health and safety. Effective pediatric eye injury prevention systems require a multifactorial approach combining legislation, policies, standards, education, and personal eye protection to limit exposure to ocular hazards. A paucity of standardized measurement and lack of funding have limited advances in the field of children's eye injury prevention. Improved eye injury surveillance and research funding along with collaboration with health care providers are important components for strategies to prevent pediatric ocular trauma.
2012-01-01
Background Dry eye syndrome (DES) is a common ocular disorder occurring in general population. The purpose of this study is to evaluate the impact of DES on vision-related quality of life (QoL) in a non-clinic-based general population. Methods This population-based cross-sectional study enrolled subjects older than 40 years, who took part in an epidemiological study on dry eye in Sanle Community, Shanghai. Apart from the collection of sociodemographics, dry eye symptoms, and other clinical data, a Chinese version of the 25-item National Eye Institute Visual Functioning Questionnaire (NEI VFQ-25) was administered to all subjects. Comparisons of the NEI VFQ-25 subscale item scores and composite score were made among subgroups divided according to the presence of dry eye symptoms or signs. Multivariate regression analysis was performed to investigate the relationship between the clinical variables and the VFQ-25 composite score. Results A total of 229 participants were enrolled in the study, with an average age of (60.7 ±10.1) years old. Majority of these participants were female (59.8 %, 137/229). The total DES symptom scores (TDSS) in subjects either with definite DES or only with dry eye symptoms were significantly higher (F = 60.331, P < 0.001). The values of tear break-up time (TBUT) and Schirmer test were significantly lower in participants with DES and those with dry eye signs only (F = 55.158 and 40.778, P < 0.001). The composite score of the NEI VFQ-25 was significantly lower in subjects with DES (F = 4.901, P = 0.003). Moreover, the subscale scores of ocular pain and mental health were significantly lower in those with either DES or dry eye symptoms only (F = 10.962 and 7.362 respectively, both P < 0.001). The multiple regression analysis showed that the TDSS had a significant negative correlation with the VFQ-25 composite score as well as with the subscale score for ocular pain and mental health, even after the adjustment of all other factors (all P < 0.01). Conclusions The symptoms of dry eye are associated with an adverse impact on vision-related QoL in non-clinic-based general population, which is mainly represented as more ocular pain and discomfort, and impaired mental health as well. Apart from clinical examination, it is also important to refer to subjective symptoms and QoL scores when assessing the severity of DES. PMID:22799274
Cyclodextrins in eye drop formulations: enhanced topical delivery of corticosteroids to the eye.
Loftsson, Thorsteinn; Stefánsson, Einar
2002-04-01
Cyclodextrins are cylindrical oligosaccharides with a lipophilic central cavity and hydrophilic outer surface. They can form water-soluble complexes with lipophilic drugs, which 'hide' in the cavity. Cyclodextrins can be used to form aqueous eye drop solutions with lipophilic drugs, such as steroids and some carbonic anhydrase inhibitors. The cyclodextrins increase the water solubility of the drug, enhance drug absorption into the eye, improve aqueous stability and reduce local irritation. Cyclodextrins are useful excipients in eye drop formulations of various drugs, including steroids of any kind, carbonic anhydrase inhibitors, pilocarpine, cyclosporins, etc. Their use in ophthalmology has already begun and is likely to expand the selection of drugs available as eye drops. In this paper we review the properties of cyclodextrins and their application in eye drop formulations, of which their use in the formulation of dexamethasone eye drops is an example. Cyclodextrins have been used to formulate eye drops containing corticosteroids, such as dexamethasone, with levels of concentration and ocular absorption which, according to human and animal studies, are many times those seen with presently available formulations. Cyclodextrin-based dexamethasone eye drops are well tolerated in the eye and seem to provide a higher degree of bioavailability and clinical efficiency than the steroid eye drop formulations presently available. Such formulations offer the possibility of once per day application of corticosteroid eye drops after eye surgery, and more intensive topical steroid treatment in severe inflammation. While cyclodextrins have been known for more than a century, their use in ophthalmology is just starting. Cyclodextrins are useful excipients in eye drop formulations for a variety of lipophilic drugs. They will facilitate eye drop formulations for drugs that otherwise might not be available for topical use, while improving absorption and stability and decreasing local irritation.
Enhanced iris recognition method based on multi-unit iris images
NASA Astrophysics Data System (ADS)
Shin, Kwang Yong; Kim, Yeong Gon; Park, Kang Ryoung
2013-04-01
For the purpose of biometric person identification, iris recognition uses the unique characteristics of the patterns of the iris; that is, the eye region between the pupil and the sclera. When obtaining an iris image, the iris's image is frequently rotated because of the user's head roll toward the left or right shoulder. As the rotation of the iris image leads to circular shifting of the iris features, the accuracy of iris recognition is degraded. To solve this problem, conventional iris recognition methods use shifting of the iris feature codes to perform the matching. However, this increases the computational complexity and level of false acceptance error. To solve these problems, we propose a novel iris recognition method based on multi-unit iris images. Our method is novel in the following five ways compared with previous methods. First, to detect both eyes, we use Adaboost and a rapid eye detector (RED) based on the iris shape feature and integral imaging. Both eyes are detected using RED in the approximate candidate region that consists of the binocular region, which is determined by the Adaboost detector. Second, we classify the detected eyes into the left and right eyes, because the iris patterns in the left and right eyes in the same person are different, and they are therefore considered as different classes. We can improve the accuracy of iris recognition using this pre-classification of the left and right eyes. Third, by measuring the angle of head roll using the two center positions of the left and right pupils, detected by two circular edge detectors, we obtain the information of the iris rotation angle. Fourth, in order to reduce the error and processing time of iris recognition, adaptive bit-shifting based on the measured iris rotation angle is used in feature matching. Fifth, the recognition accuracy is enhanced by the score fusion of the left and right irises. Experimental results on the iris open database of low-resolution images showed that the averaged equal error rate of iris recognition using the proposed method was 4.3006%, which is lower than that of other methods.
Keller, Jürgen; Krimly, Amon; Bauer, Lisa; Schulenburg, Sarah; Böhm, Sarah; Aho-Özhan, Helena E A; Uttner, Ingo; Gorges, Martin; Kassubek, Jan; Pinkhardt, Elmar H; Abrahams, Sharon; Ludolph, Albert C; Lulé, Dorothée
2017-08-01
Reliable assessment of cognitive functions is a challenging task in amyotrophic lateral sclerosis (ALS) patients unable to speak and write. We therefore present an eye-tracking based neuropsychological screening tool based on the Edinburgh Cognitive and Behavioural ALS Screen (ECAS), a standard screening tool for cognitive deficits in ALS. In total, 46 ALS patients and 50 healthy controls matched for age, gender and education were tested with an oculomotor based and a standard paper-and-pencil version of the ECAS. Significant correlation between both versions was observed for ALS patients and healthy controls in the ECAS total score and in all of its ALS-specific domains (all r > 0.3; all p < 0.05). The eye-tracking version of the ECAS reliably distinguished between ALS patients and healthy controls in the ECAS total score (p < 0.05). Also, cognitively impaired and non-impaired patients could be reliably distinguished with a specificity of 95%. This study provides first evidence that the eye-tracking based ECAS version is a promising approach for assessing cognitive deficits in ALS patients who are unable to speak or write.
Exploration of an oculometer-based model of pilot workload
NASA Technical Reports Server (NTRS)
Krebs, M. J.; Wingert, J. W.; Cunningham, T.
1977-01-01
Potential relationships between eye behavior and pilot workload are discussed. A Honeywell Mark IIA oculometer was used to obtain the eye data in a fixed base transport aircraft simulation facility. The data were analyzed to determine those parameters of eye behavior which were related to changes in level of task difficulty of the simulated manual approach and landing on instruments. A number of trends and relationships between eye variables and pilot ratings were found. A preliminary equation was written based on the results of a stepwise linear regression. High variability in time spent on various instruments was related to differences in scanning strategy among pilots. A more detailed analysis of individual runs by individual pilots was performed to investigate the source of this variability more closely. Results indicated a high degree of intra-pilot variability in instrument scanning. No consistent workload related trends were found. Pupil diameter which had demonstrated a strong relationship to task difficulty was extensively re-exmained.
Call, Gerald B.; Olson, John M.; Chen, Jiong; Villarasa, Nikki; Ngo, Kathy T.; Yabroff, Allison M.; Cokus, Shawn; Pellegrini, Matteo; Bibikova, Elena; Bui, Chris; Cespedes, Albert; Chan, Cheryl; Chan, Stacy; Cheema, Amrita K.; Chhabra, Akanksha; Chitsazzadeh, Vida; Do, Minh-Tu; Fang, Q. Angela; Folick, Andrew; Goodstein, Gelsey L.; Huang, Cheng R.; Hung, Tony; Kim, Eunha; Kim, William; Kim, Yulee; Kohan, Emil; Kuoy, Edward; Kwak, Robert; Lee, Eric; Lee, JiEun; Lin, Henry; Liu, H-C. Angela; Moroz, Tatiana; Prasad, Tharani; Prashad, Sacha L.; Patananan, Alexander N.; Rangel, Alma; Rosselli, Desiree; Sidhu, Sohrab; Sitz, Daniel; Taber, Chelsea E.; Tan, Jingwen; Topp, Kasey; Tran, PhuongThao; Tran, Quynh-Minh; Unkovic, Mary; Wells, Maggie; Wickland, Jessica; Yackle, Kevin; Yavari, Amir; Zaretsky, Jesse M.; Allen, Christopher M.; Alli, Latifat; An, Ju; Anwar, Abbas; Arevalo, Sonia; Ayoub, Danny; Badal, Shawn S.; Baghdanian, Armonde; Baghdanian, Arthur H.; Baumann, Sara A.; Becerra, Vivian N.; Chan, Hei J.; Chang, Aileen E.; Cheng, Xibin A.; Chin, Mabel; Chong, Fleurette; Crisostomo, Carlyn; Datta, Sanjit; Delosreyes, Angela; Diep, Francie; Ekanayake, Preethika; Engeln, Mark; Evers, Elizabeth; Farshidi, Farzin; Fischer, Katrina; Formanes, Arlene J.; Gong, Jun; Gupta, Riju; Haas, Blake E.; Hahm, Vicky; Hsieh, Michael; Hui, James Z.; Iao, Mei L.; Jin, Sophia D.; Kim, Angela Y.; Kim, Lydia S-H.; King, Megan; Knudsen-Robbins, Chloe; Kohanchi, David; Kovshilovskaya, Bogdana; Ku, Amy; Kung, Raymond W.; Landig, Mark E. L.; Latterman, Stephanie S.; Lauw, Stephanie S.; Lee, Daniel S.; Lee, Joann S.; Lei, Kai C.; Leung, Lesley L.; Lerner, Renata; Lin, Jian-ya; Lin, Kathleen; Lim, Bryon C.; Lui, Crystal P. Y.; Liu, Tiffany Q.; Luong, Vincent; Makshanoff, Jacob; Mei, An-Chi; Meza, Miguel; Mikhaeil, Yara A.; Moarefi, Majid; Nguyen, Long H.; Pai, Shekhar S.; Pandya, Manish; Patel, Aadit R.; Picard, Paul D.; Safaee, Michael M.; Salame, Carol; Sanchez, Christian; Sanchez, Nina; Seifert, Christina C.; Shah, Abhishek; Shilgevorkyan, Oganes H.; Singh, Inderroop; Soma, Vanessa; Song, Junia J.; Srivastava, Neetika; Sta.Ana, Jennifer L.; Sun, Christie; Tan, Diane; Teruya, Alison S.; Tikia, Robyn; Tran, Trinh; Travis, Emily G.; Trinh, Jennifer D.; Vo, Diane; Walsh, Thomas; Wong, Regan S.; Wu, Katherine; Wu, Ya-Whey; Yang, Nkau X. V.; Yeranosian, Michael; Yu, James S.; Zhou, Jennifer J.; Zhu, Ran X.; Abrams, Anna; Abramson, Amanda; Amado, Latiffe; Anderson, Jenny; Bashour, Keenan; Beyer, Elsa; Bookatz, Allen; Brewer, Sarah; Buu, Natalie; Calvillo, Stephanie; Cao, Joseph; Chan, Amy; Chan, Jenny; Chang, Aileen; Chang, Daniel; Chang, Yuli; Chen, YiBing; Choi, Joo; Chou, Jeyling; Dang, Peter; Datta, Sumit; Davarifar, Ardy; Deravanesian, Artemis; Desai, Poonam; Fabrikant, Jordan; Farnad, Shahbaz; Fu, Katherine; Garcia, Eddie; Garrone, Nick; Gasparyan, Srpouhi; Gayda, Phyllis; Go, Sherrylene; Goffstein, Chad; Gonzalez, Courtney; Guirguis, Mariam; Hassid, Ryan; Hermogeno, Brenda; Hong, Julie; Hong, Aria; Hovestreydt, Lindsay; Hu, Charles; Huff, Devon; Jamshidian, Farid; Jen, James; Kahen, Katrin; Kao, Linda; Kelley, Melissa; Kho, Thomas; Kim, Yein; Kim, Sarah; Kirkpatrick, Brian; Langenbacher, Adam; Laxamana, Santino; Lee, Janet; Lee, Chris; Lee, So-Youn; Lee, ToHang S.; Lee, Toni; Lewis, Gemma; Lezcano, Sheila; Lin, Peter; Luu, Thanh; Luu, Julie; Marrs, Will; Marsh, Erin; Marshall, Jamie; Min, Sarah; Minasian, Tanya; Minye, Helena; Misra, Amit; Morimoto, Miles; Moshfegh, Yasaman; Murray, Jessica; Nguyen, Kha; Nguyen, Cynthia; Nodado, Ernesto; O'Donahue, Amanda; Onugha, Ndidi; Orjiakor, Nneka; Padhiar, Bhavin; Paul, Eric; Pavel-Dinu, Mara; Pavlenko, Alex; Paz, Edwin; Phaklides, Sarah; Pham, Lephong; Poulose, Preethi; Powell, Russell; Pusic, Aya; Ramola, Divi; Regalia, Kirsten; Ribbens, Meghann; Rifai, Bassel; Saakyan, Manyak; Saarikoski, Pamela; Segura, Miriam; Shadpour, Farnaz; Shemmassian, Aram; Singh, Ramnik; Singh, Vivek; Skinner, Emily; Solomin, Daniel; Soneji, Kosha; Spivey, Kristin; Stageberg, Erika; Stavchanskiy, Marina; Tekchandani, Leena; Thai, Leo; Thiyanaratnam, Jayantha; Tong, Maurine; Toor, Aneet; Tovar, Steve; Trangsrud, Kelly; Tsang, Wah-Yung; Uemura, Marc; Vollmer, Emily; Weiss, Emily; Wood, Damien; Wu, Joy; Wu, Sophia; Wu, Winston; Xu, Qing; Yamauchi, Yuki; Yarosh, Will; Yee, Laura; Yen, George; Banerjee, Utpal
2007-01-01
Using a large consortium of undergraduate students in an organized program at the University of California, Los Angeles (UCLA), we have undertaken a functional genomic screen in the Drosophila eye. In addition to the educational value of discovery-based learning, this article presents the first comprehensive genomewide analysis of essential genes involved in eye development. The data reveal the surprising result that the X chromosome has almost twice the frequency of essential genes involved in eye development as that found on the autosomes. PMID:17720911
A Novel Animal Model for Investigating the Neural Basis of Focal Dystonia
2016-09-01
basal ganglia as the predisposing condition and dry eye as an environmental trigger. Based on experiments during the 1st year of the grant, our...experiments and preliminary recordings from the superior colliculus. 15. SUBJECT TERMS Dystonia, benign essential blepharospasm, dry eye , motor...that hypersynchronized, 7 Hz neuronal oscilla‐ tions of the basal ganglia created the predisposing condition and that eye irritation from dry eye was
Image-Based Grouping during Binocular Rivalry Is Dictated by Eye-Of-Origin
Stuit, Sjoerd M.; Paffen, Chris L. E.; van der Smagt, Maarten J.; Verstraten, Frans A. J.
2014-01-01
Prolonged viewing of dichoptically presented images with different content results in perceptual alternations known as binocular rivalry. This phenomenon is thought to be the result of competition at a local level, where local rivalry zones interact to give rise to a single, global dominant percept. Certain perceived combinations that result from this local competition are known to last longer than others, which is referred to as grouping during binocular rivalry. In recent years, the phenomenon has been suggested to be the result of competition at both eye- and image-based processing levels, although the exact contribution from each level remains elusive. Here we use a paradigm designed specifically to quantify the contribution of eye- and image-based processing to grouping during rivalry. In this paradigm we used sine-wave gratings as well as upright and inverted faces, with and without binocular disparity-based occlusion. These stimuli and conditions were used because they are known to result in processing at different stages throughout the visual processing hierarchy. Specifically, more complex images were included in order to maximize the potential contribution of image-based grouping. In spite of this, our results show that increasing image complexity did not lead to an increase in the contribution of image-based processing to grouping during rivalry. In fact, the results show that grouping was primarily affected by the eye-of-origin of the image parts, irrespective of stimulus type. We suggest that image content affects grouping during binocular rivalry at low-level processing stages, where it is intertwined with eye-of-origin information. PMID:24987847
Myopic refractive shift represents dense nuclear sclerosis and thin lens in lenticular myopia.
Cho, Yang Kyung; Huang, Wei; Nishimura, Eiichi
2013-09-01
It is not rare to meet unilateral nuclear sclerotic cataracts with myopic refractive changes (lenticular myopia) compared with the fellow eye in the ophthalmic examination of patients with decreased visual acuity. To determine the relationship between the myopic refractive changes and interocular differences of parameters, we investigated the interocular differences of ocular parameters between a lenticular myopic eye and the fellow eye. This retrospective study included 68 eyes of 34 patients, who showed unilateral lenticular myopia. We compared the dimensions of ocular component, such as anterior chamber depth, anterior chamber volume, lens thickness, vitreous chamber depth, lens position, lens density of nuclear sclerosis, anterior lens curvature and myopic refractive changes (spherical equivalent refraction) between the lenticular myopic eye and the myopic refractive change were examined. Statistically significant differences were found between the lenticular myopic eye and the fellow eye for anterior chamber depth (p = 0.015) anterior chamber volume (p = 0.031), lens thickness (p < 0.001), lens density of the nuclear sclerosis (p < 0.001) and the spherical equivalent myopic refractive changes (p < 0.001). Based on univariate analysis, the interocular difference in spherical equivalent refraction was significantly correlated with interocular differences of the density of the nuclear sclerosis (r = 0.79, p < 0.001), lens thickness (r = -0.70, p < 0.001) and vitreous chamber depth (r = 0.43, p = 0.012). Based on multiple regression analysis, the interocular difference in spherical equivalent refraction was significantly correlated with interocular differences of density of nuclear sclerosis (p < 0.001) and lens thickness (p = 0.007). The difference in myopic spherical change reflects the differences in the severity of nuclear sclerosis and lens thickness between the lenticular myopic eye and the fellow eye. © 2013 The Authors. Clinical and Experimental Optometry © 2013 Optometrists Association Australia.
Mucosal complications of modified osteo-odonto keratoprosthesis in chronic Stevens-Johnson syndrome.
Basu, Sayan; Pillai, Vinay Sukumara; Sangwan, Virender S
2013-11-01
To describe clinical outcomes of complications afflicting the autologous oral mucous membrane graft after modified osteo-odonto keratoprosthesis surgery in chronic Stevens-Johnson syndrome (SJS). Prospective case series. This study included 30 eyes of 30 patients with SJS-induced dry keratinized ocular surfaces; the patients underwent various stages of this procedure between August 2009 and February 2012. Mucosal complications were classified as either necrosis or overgrowth. Mucosal necrosis was managed according to a predesigned algorithm based on timing (pre- and postimplantation) and location (central or peripheral) of necrosis. Cases with mucosal overgrowth underwent mucosal debulking and trimming. Mucosal necrosis developed in 15 (50%) eyes and overgrowth in 4 (13.3%) eyes. Preimplantation necrosis (n = 7) was initially managed conservatively, but 2 eyes required free labial-mucous membrane grafting for persistent corneal exposure. Free labial-mucous membrane grafting was performed in all cases of postimplantation necrosis (n = 10), but 8 eyes required additional tarsal pedicle flaps (n = 6, for peripheral necrosis) or through-the-lid revisions (n = 2, for central necrosis). Debulking and trimming effectively managed all cases of mucosal overgrowth, but 3 eyes required repeat procedures. At 24.1 ± 6.5 months postimplantation, the keratoprosthesis was retained in all eyes, and the probability of maintaining 20/60 or better vision was similar in eyes with or without mucosal necrosis (86 ± 8.8% vs 80 ± 10.3%). Mucosal complications, especially necrosis, occurred commonly following modified osteo-odonto keratoprosthesis surgery in dry keratinized post-SJS eyes. The algorithm-based management approach described in this study was successful in treating these complications, retaining the prosthesis and preserving useful vision. Copyright © 2013 Elsevier Inc. All rights reserved.
Seol, Bo Ram; Kim, Dong Myung; Park, Ki Ho; Jeoung, Jin Wook
2017-11-01
To evaluate the optical coherence tomography (OCT) color probability codes based on a myopic normative database and to investigate whether the implementation of the myopic normative database can improve the OCT diagnostic ability in myopic glaucoma. Comparative validity study. In this study, 305 eyes (154 myopic healthy eyes and 151 myopic glaucoma eyes) were included. A myopic normative database was obtained based on myopic healthy eyes. We evaluated the agreement between OCT color probability codes after applying the built-in and myopic normative databases, respectively. Another 120 eyes (60 myopic healthy eyes and 60 myopic glaucoma eyes) were included and the diagnostic performance of OCT color codes using a myopic normative database was investigated. The mean weighted kappa (Kw) coefficients for quadrant retinal nerve fiber layer (RNFL) thickness, clock-hour RNFL thickness, and ganglion cell-inner plexiform layer (GCIPL) thickness were 0.636, 0.627, and 0.564, respectively. The myopic normative database showed a higher specificity than did the built-in normative database in quadrant RNFL thickness, clock-hour RNFL thickness, and GCIPL thickness (P < .001, P < .001, and P < .001, respectively). The receiver operating characteristic curve values increased when using the myopic normative database in quadrant RNFL thickness, clock-hour RNFL thickness, and GCIPL thickness (P = .011, P = .004, P < .001, respectively). The diagnostic ability of OCT color codes for detection of myopic glaucoma significantly improved after application of the myopic normative database. The implementation of a myopic normative database is needed to allow more precise interpretation of OCT color probability codes when used in myopic eyes. Copyright © 2017 Elsevier Inc. All rights reserved.
Parallax barrier engineering for image quality improvement in an autostereoscopic 3D display.
Kim, Sung-Kyu; Yoon, Ki-Hyuk; Yoon, Seon Kyu; Ju, Heongkyu
2015-05-18
We present a image quality improvement in a parallax barrier (PB)-based multiview autostereoscopic 3D display system under a real-time tracking of positions of a viewer's eyes. The system presented exploits a parallax barrier engineered to offer significantly improved quality of three-dimensional images for a moving viewer without an eyewear under the dynamic eye tracking. The improved image quality includes enhanced uniformity of image brightness, reduced point crosstalk, and no pseudoscopic effects. We control the relative ratio between two parameters i.e., a pixel size and the aperture of a parallax barrier slit to improve uniformity of image brightness at a viewing zone. The eye tracking that monitors positions of a viewer's eyes enables pixel data control software to turn on only pixels for view images near the viewer's eyes (the other pixels turned off), thus reducing point crosstalk. The eye tracking combined software provides right images for the respective eyes, therefore producing no pseudoscopic effects at its zone boundaries. The viewing zone can be spanned over area larger than the central viewing zone offered by a conventional PB-based multiview autostereoscopic 3D display (no eye tracking). Our 3D display system also provides multiviews for motion parallax under eye tracking. More importantly, we demonstrate substantial reduction of point crosstalk of images at the viewing zone, its level being comparable to that of a commercialized eyewear-assisted 3D display system. The multiview autostereoscopic 3D display presented can greatly resolve the point crosstalk problem, which is one of the critical factors that make it difficult for previous technologies for a multiview autostereoscopic 3D display to replace an eyewear-assisted counterpart.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, J; Lee, J; Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul
Purpose: To evaluate the effect of a tungsten eye-shield on the dose distribution of a patient. Methods: A 3D scanner was used to extract the dimension and shape of a tungsten eye-shield in the STL format. Scanned data was transferred into a 3D printer. A dummy eye shield was then produced using bio-resin (3D systems, VisiJet M3 Proplast). For a patient with mucinous carcinoma, the planning CT was obtained with the dummy eye-shield placed on the patient’s right eye. Field shaping of 6 MeV was performed using a patient-specific cerrobend block on the 15 x 15 cm{sup 2} applicator. Themore » gantry angle was 330° to cover the planning target volume near by the lens. EGS4/BEAMnrc was commissioned from our measurement data from a Varian 21EX. For the CT-based dose calculation using EGS4/DOSXYZnrc, the CT images were converted to a phantom file through the ctcreate program. The phantom file had the same resolution as the planning CT images. By assigning the CT numbers of the dummy eye-shield region to 17000, the real dose distributions below the tungsten eye-shield were calculated in EGS4/DOSXYZnrc. In the TPS, the CT number of the dummy eye-shield region was assigned to the maximum allowable CT number (3000). Results: As compared to the maximum dose, the MC dose on the right lens or below the eye shield area was less than 2%, while the corresponding RTP calculated dose was an unrealistic value of approximately 50%. Conclusion: Utilizing a 3D scanner and a 3D printer, a dummy eye-shield for electron treatment can be easily produced. The artifact-free CT images were successfully incorporated into the CT-based Monte Carlo simulations. The developed method was useful in predicting the realistic dose distributions around the lens blocked with the tungsten shield.« less
Can Changes in Eye Movement Scanning Alter the Age-Related Deficit in Recognition Memory?
Chan, Jessica P. K.; Kamino, Daphne; Binns, Malcolm A.; Ryan, Jennifer D.
2011-01-01
Older adults typically exhibit poorer face recognition compared to younger adults. These recognition differences may be due to underlying age-related changes in eye movement scanning. We examined whether older adults’ recognition could be improved by yoking their eye movements to those of younger adults. Participants studied younger and older faces, under free viewing conditions (bases), through a gaze-contingent moving window (own), or a moving window which replayed the eye movements of a base participant (yoked). During the recognition test, participants freely viewed the faces with no viewing restrictions. Own-age recognition biases were observed for older adults in all viewing conditions, suggesting that this effect occurs independently of scanning. Participants in the bases condition had the highest recognition accuracy, and participants in the yoked condition were more accurate than participants in the own condition. Among yoked participants, recognition did not depend on age of the base participant. These results suggest that successful encoding for all participants requires the bottom-up contribution of peripheral information, regardless of the locus of control of the viewer. Although altering the pattern of eye movements did not increase recognition, the amount of sampling of the face during encoding predicted subsequent recognition accuracy for all participants. Increased sampling may confer some advantages for subsequent recognition, particularly for people who have declining memory abilities. PMID:21687460
Tovar-Aguilar, J Antonio; Monaghan, Paul F; Bryant, Carol A; Esposito, Andrew; Wade, Mark; Ruiz, Omar; McDermott, Robert J
2014-01-01
For the last 10 years, the Partnership for Citrus Workers Health (PCWH) has been an evidence-based intervention program that promotes the adoption of protective eye safety equipment among Spanish-speaking farmworkers of Florida. At the root of this program is the systematic use of community-based preventive marketing (CBPM) and the training of community health workers (CHWs) among citrus harvester using popular education. CBPM is a model that combines the organizational system of community-based participatory research (CBPR) and the strategies of social marketing. This particular program relied on formative research data using a mixed-methods approach and a multilevel stakeholder analysis that allowed for rapid dissemination, effective increase of personal protective equipment (PPE) usage, and a subsequent impact on adoptive workers and companies. Focus groups, face-to-face interviews, surveys, participant observation, Greco-Latin square, and quasi-experimental tests were implemented. A 20-hour popular education training produced CHWs that translated results of the formative research to potential adopters and also provided first aid skills for eye injuries. Reduction of injuries is not limited to the use of safety glasses, but also to the adoption of timely intervention and regular eye hygiene. Limitations include adoption in only large companies, rapid decline of eye safety glasses without consistent intervention, technological limitations of glasses, and thorough cost-benefit analysis.
Feasibility and clinical utility of ultra-widefield indocyanine green angiography.
Klufas, Michael A; Yannuzzi, Nicolas A; Pang, Claudine E; Srinivas, Sowmya; Sadda, Srinivas R; Freund, K Bailey; Kiss, Szilárd
2015-03-01
To evaluate the feasibility and clinical utility of a novel noncontact scanning laser ophthalmoscope-based ultra-widefield indocyanine green angiographic system. Ultra-widefield indocyanine green angiographic images were captured using a modified Optos P200Tx that produced high-resolution images of the choroidal vasculature with up to a 200° field. Ultra-widefield indocyanine green angiography was performed on patients with a variety of retinal conditions to assess utility of this imaging technique for diagnostic purposes and disease treatment monitoring. Ultra-widefield indocyanine green angiography was performed on 138 eyes of 69 patients. Mean age was 58 ± 16.9 years (range, 24-85 years). The most common ocular pathologies imaged included central serous chorioretinopathy (24 eyes), uveitis (various subtypes, 16 eyes), age-related macular degeneration (12 eyes), and polypoidal choroidal vasculopathy (4 eyes). In all eyes evaluated with ultra-widefield indocyanine green angiography, high-resolution images of choroidal and retinal circulation were obtained with sufficient detail out to 200° of the fundus. In this series of 138 eyes, scanning laser ophthalmoscope-based ultra-widefield indocyanine green angiography was clinically practical and provided detailed images of both the central and peripheral choroidal circulation. Future studies are needed to refine the clinical value of this imaging modality and the significance of peripheral choroidal vascular changes in the diagnosis, monitoring, and treatment of ocular diseases.
Bricker-Anthony, Courtney; Hines-Beard, Jessica
2016-01-01
Abstract Purpose: Characterization of the response of the Balb/c mouse to an eye-directed overpressure airwave, with the hypothesis that this mouse strain and model is useful for testing potential therapeutics for the treatment of traumatic eye injury. Methods: The left eyes of adult Balb/c mice were exposed to an eye-directed overpressure airwave. Intraocular pressure (IOP) was measured and eyes were inspected for gross pathology changes. Optical coherence tomography and histology were used to examine the structural integrity of the retina and optic nerve. Immunohistochemistry, in vivo molecular fluorophores, and a multiplex enzyme-linked immunosorbent assay were utilized to identify changes in cell death, neuroinflammation, and oxidative stress. Results: This model induced a transient increase in IOP, corneal injuries, infrequent large retinal detachments, retinal pigment epithelium (RPE) vacuolization, glial reactivity, and retinal cell death. Both the corneal damage and RPE vacuolization persisted with time. Optic nerve degeneration occurred as early as 7 days postinjury and persisted out to 60 days. Retinal cell death, increased levels of reactive oxygen species, and neuroinflammation were detected at 7 days postinjury. Conclusions: The injury profile of the Balb/c mouse is consistent with commonly observed pathologies in blast-exposed patients. The damage is throughout the eye and persistent, making this mouse model useful for testing cell-based therapies. PMID:26982447
Epidemiology of hereditary ocular disorders.
Rosenberg, Thomas
2003-01-01
Molecular genetic evidence has contributed significantly to the understanding of the fundamental molecular biology of the eye in health and disease, but it has also exposed the inadequacy of our traditional clinically based classification of hereditary eye disorders by unravelling significant genetic non-allelic heterogeneity in many eye disorders. Furthermore, our understanding of the epidemiology of hereditary ocular disorders has gained considerably by the establishment of mutation spectra in a rapidly growing number of monogenic eye disorders. In this overview, special emphasis has been put on the growing impact of genetic eye diseases in visual impairment, genetic heterogeneity, and the role of founder mutations for the skewed appearance of certain hereditary ocular disorders in some populations.
Fukushima, Kikuro; Fukushima, Junko; Warabi, Tateo
2011-01-01
Smooth-pursuit eye movements are voluntary responses to small slow-moving objects in the fronto-parallel plane. They evolved in primates, who possess high-acuity foveae, to ensure clear vision about the moving target. The primate frontal cortex contains two smooth-pursuit related areas; the caudal part of the frontal eye fields (FEF) and the supplementary eye fields (SEF). Both areas receive vestibular inputs. We review functional differences between the two areas in smooth-pursuit. Most FEF pursuit neurons signal pursuit parameters such as eye velocity and gaze-velocity, and are involved in canceling the vestibulo-ocular reflex by linear addition of vestibular and smooth-pursuit responses. In contrast, gaze-velocity signals are rarely represented in the SEF. Most FEF pursuit neurons receive neck velocity inputs, while discharge modulation during pursuit and trunk-on-head rotation adds linearly. Linear addition also occurs between neck velocity responses and vestibular responses during head-on-trunk rotation in a task-dependent manner. During cross-axis pursuit–vestibular interactions, vestibular signals effectively initiate predictive pursuit eye movements. Most FEF pursuit neurons discharge during the interaction training after the onset of pursuit eye velocity, making their involvement unlikely in the initial stages of generating predictive pursuit. Comparison of representative signals in the two areas and the results of chemical inactivation during a memory-based smooth-pursuit task indicate they have different roles; the SEF plans smooth-pursuit including working memory of motion–direction, whereas the caudal FEF generates motor commands for pursuit eye movements. Patients with idiopathic Parkinson’s disease were asked to perform this task, since impaired smooth-pursuit and visual working memory deficit during cognitive tasks have been reported in most patients. Preliminary results suggested specific roles of the basal ganglia in memory-based smooth-pursuit. PMID:22174706
Ito, Norie; Barnes, Graham R; Fukushima, Junko; Fukushima, Kikuro; Warabi, Tateo
2013-08-01
Using a cue-dependent memory-based smooth-pursuit task previously applied to monkeys, we examined the effects of visual motion-memory on smooth-pursuit eye movements in normal human subjects and compared the results with those of the trained monkeys. These results were also compared with those during simple ramp-pursuit that did not require visual motion-memory. During memory-based pursuit, all subjects exhibited virtually no errors in either pursuit-direction or go/no-go selection. Tracking eye movements of humans and monkeys were similar in the two tasks, but tracking eye movements were different between the two tasks; latencies of the pursuit and corrective saccades were prolonged, initial pursuit eye velocity and acceleration were lower, peak velocities were lower, and time to reach peak velocities lengthened during memory-based pursuit. These characteristics were similar to anticipatory pursuit initiated by extra-retinal components during the initial extinction task of Barnes and Collins (J Neurophysiol 100:1135-1146, 2008b). We suggest that the differences between the two tasks reflect differences between the contribution of extra-retinal and retinal components. This interpretation is supported by two further studies: (1) during popping out of the correct spot to enhance retinal image-motion inputs during memory-based pursuit, pursuit eye velocities approached those during simple ramp-pursuit, and (2) during initial blanking of spot motion during memory-based pursuit, pursuit components appeared in the correct direction. Our results showed the importance of extra-retinal mechanisms for initial pursuit during memory-based pursuit, which include priming effects and extra-retinal drive components. Comparison with monkey studies on neuronal responses and model analysis suggested possible pathways for the extra-retinal mechanisms.
High-Speed Noninvasive Eye-Tracking System
NASA Technical Reports Server (NTRS)
Talukder, Ashit; LaBaw, Clayton; Michael-Morookian, John; Monacos, Steve; Serviss, Orin
2007-01-01
The figure schematically depicts a system of electronic hardware and software that noninvasively tracks the direction of a person s gaze in real time. Like prior commercial noninvasive eye-tracking systems, this system is based on (1) illumination of an eye by a low-power infrared light-emitting diode (LED); (2) acquisition of video images of the pupil, iris, and cornea in the reflected infrared light; (3) digitization of the images; and (4) processing the digital image data to determine the direction of gaze from the centroids of the pupil and cornea in the images. Relative to the prior commercial systems, the present system operates at much higher speed and thereby offers enhanced capability for applications that involve human-computer interactions, including typing and computer command and control by handicapped individuals,and eye-based diagnosis of physiological disorders that affect gaze responses.
New optical scheme for a polarimetric-based glucose sensor
NASA Technical Reports Server (NTRS)
Ansari, Rafat R.; Bockle, Stefan; Rovati, Luigi
2004-01-01
A new optical scheme to detect glucose concentration in the aqueous humor of the eye is presented. The ultimate aim is to apply this technique in designing a new instrument for, routinely and frequently, noninvasively monitoring blood glucose levels in diabetic patients without contact (no index matching) between the eye and the instrument. The optical scheme exploits the Brewster reflection of circularly polarized light off of the lens of the eye. Theoretically, this reflected linearly polarized light on its way to the detector is expected to rotate its state of polarization, owing to the presence of glucose molecules in the aqueous humor of a patient's eye. An experimental laboratory setup based on this scheme was designed and tested by measuring a range of known concentrations of glucose solutions dissolved in water. (c) 2004 Society of Photo-Optical Instrumentation Engineers.
NASA Astrophysics Data System (ADS)
Gao, Pei-pei; Liu, Feng
2016-10-01
With the development of information technology and artificial intelligence, speech synthesis plays a significant role in the fields of Human-Computer Interaction Techniques. However, the main problem of current speech synthesis techniques is lacking of naturalness and expressiveness so that it is not yet close to the standard of natural language. Another problem is that the human-computer interaction based on the speech synthesis is too monotonous to realize mechanism of user subjective drive. This thesis introduces the historical development of speech synthesis and summarizes the general process of this technique. It is pointed out that prosody generation module is an important part in the process of speech synthesis. On the basis of further research, using eye activity rules when reading to control and drive prosody generation was introduced as a new human-computer interaction method to enrich the synthetic form. In this article, the present situation of speech synthesis technology is reviewed in detail. Based on the premise of eye gaze data extraction, using eye movement signal in real-time driving, a speech synthesis method which can express the real speech rhythm of the speaker is proposed. That is, when reader is watching corpora with its eyes in silent reading, capture the reading information such as the eye gaze duration per prosodic unit, and establish a hierarchical prosodic pattern of duration model to determine the duration parameters of synthesized speech. At last, after the analysis, the feasibility of the above method is verified.
Using InterWave Aberrometry to Measure and Improve the Quality of Vision in LASIK Surgery
Thompson, Keith P.; Staver, P. Randall; Garcia, Jose R.; Burns, Stephen A.; Webb, Robert H.; Stulting, R. Doyle
2005-01-01
Objective To compare visual outcomes in eyes undergoing aberrometry-guided (InterWave) LASIK with those in eyes undergoing standard LASIK treatment based upon refractive measures. Design Single-center, comparative, interventional, consecutive case series. Participants Four hundred two consecutive eyes undergoing LASIK were analyzed retrospectively. One group, 106 eyes undergoing primary LASIK and 224 eyes undergoing LASIK enhancement, was treated with standard LASIK treatment using a 5.5-mm optical zone, 1.5-mm transition zone laser with the settings determined by manifest refraction. The second group, 44 untreated (primary) eyes and 28 previously treated (enhancement) eyes, received a multipass, multistage treatment in which the laser settings for each stage were determined by aberrometry measurements. Eyes with desired monovision (undercorrected) outcome and preoperative hyperopia were excluded from the study. Intervention An aberrometry-guided laser treatment (InterWave LASIK) was compared with the standard LASIK treatment based upon the manifest refraction. Main Outcome Measures Uncorrected visual acuity (VA), manifest refraction, best spectacle-corrected VA (BSCVA), severity of halos, and root mean square (RMS) retinal blur area measured at 3 months postoperatively. Results Three months postoperatively there was no difference in uncorrected VA, BSCVA, refraction, or RMS retinal blur areas for pupil sizes of 3.5 mm between eyes treated by InterWave and those treated by standard LASIK. However, InterWave LASIK reduced the retinal blur area by 48% (P<0.0103) and 58% (P<0.0004) in primary cases and 43% (P<0.0430) and 74% (P<0.0271) in enhancement cases, respectively, for pupil sizes of 4.5 and 6.5 mm relative to standard LASIK treatments. Patients undergoing InterWave-guided treatment reported less severity of halo (0.37 vs. 0.98 [P<0.016] for primary cases and 0.35 vs. 0.73 [P<0.04] for enhancement cases). Conclusion InterWave LASIK achieved acuity and refractive results equivalent to those of standard LASIK treatment based upon refraction, but resulted in superior quality mesopic vision. PMID:15234139
Determinants of Utilization of Eye Care Services in a Rural Adult Population of a Developing Country
Olusanya, Bolutife A.; Ashaye, Adeyinka O.; Owoaje, Eme T.; Baiyeroju, Aderonke M.; Ajayi, Benedictus G.
2016-01-01
Purpose: To describe the factors that determine the utilization of eye care services in a rural community in South-Western Nigeria. Methods: A descriptive cross-sectional survey using a multistage sampling technique was conducted. The main outcome measure was self-reported previous consultation of an orthodox medical facility for eye care. Results: The study sample included 643 participants. Only 122 (19%) respondents had previously visited orthodox facilities in search of eye care and 24% of those with presenting visual acuity <6/18 had sought eye care. Characteristics associated with previous utilization of eye care services were age of =70 years (odds ratio [OR] ≥ 1.7, P = 0.02); male gender (OR = 1.5, P = 0.04); literacy (OR = 1.7, P = 0.007); and residing close to an eye care facility (OR = 2.8, P < 0.001). Blind respondents were three times more likely to seek eye care (P < 0.001). Regression analysis revealed that factors associated with increased likelihood of utilization of eye care services included age ≥70 years; literacy; residence close to an eye facility; being diabetic or hypertensive; history of ocular symptoms, and blindness. Conclusions: These findings suggest that a significant proportion (75%) of adults in the study area are not utilizing eye care services and that blindness is an important determinant of utilization of eye care services. Health education and awareness campaigns about the importance and benefits of seeking eye care early, and the provision of community-based eye care programs are essential to boost the uptake of eye care services in this community as well as other rural areas of West Africa. PMID:26957847
A comparison of basal and eye-flush tears for the analysis of cat tear proteins.
Petznick, Andrea; Evans, Margaret D M; Madigan, Michele C; Markoulli, Maria; Garrett, Qian; Sweeney, Deborah F
2011-02-01
To identify a rapid and effective tear collection method providing sufficient tear volume and total protein content (TPC) for analysis of individual proteins in cats. Domestic adult short-haired cats (12-37 months; 2.7-6.6 kg) were used in the study. Basal tears without stimulation and eye-flush tears after instillation of saline (10 μl) were collected using microcapillary tubes from animal eyes either unwounded control or wounded with 9-mm central epithelial debridement giving four groups with n = 3. Tear comparisons were based on total time and rate for tear collection, TPC using micro bicinchoninic acid (BCA), tear immunoglobulin A (IgA), total matrix-metalloproteinase (MMP)-9 concentration using sandwich enzyme-linked immunosorbent assay (ELISA) and MMP-9 activity. Eye-flush tears were collected significantly faster than basal tears in wounded eyes with higher rates for tear collection in unwounded control and wounded eyes. TPC was significantly lower in eye-flush tears compared to basal tears. The relative proportion of tear IgA normalized to TPC (% IgA of TPC) was not significantly different between basal and eye-flush tears. In unwounded control eyes, MMP-9 was slightly higher in eye-flush than in basal tears; activity of MMP-9 in both tear types was similar. In wounded eyes, eye-flush tears showed highest MMP-9 levels and activity on Day 1, which subsequently decreased to Day 7. MMP-9 activity in basal tears from wounded eyes did not display changes in expression. Eye-flush tears can be collected rapidly providing sufficient tear volume and TPC. This study also indicates that eye-flush tears may be more suitable than basal tears for the analysis of MMPs following corneal wounding. © 2011 The Authors. Acta Ophthalmologica © 2011 Acta Ophthalmologica Scandinavica Foundation.
Gorynia, Inge; Schwaiger, Markus; Heinz, Andreas
2014-12-01
Based on the previous findings, it has been assumed that in schizophrenia patients, eye dominance and cannabis use will affect negative symptoms and intermanual coordination (IMC), an index of interhemispheric communication. But eye dominance, specifically the clinical findings for it, has been neglected in schizophrenia research. We therefore investigated its effects in 52 right-handed (36 right-eyed and 16 left-eyed) and 51 left-handed (35 left-eyed and 16 right-eyed) schizophrenia in-patients without and with drug use. Eye dominance affected IMC in all schizophrenia patients. When comparing right- and left-handers, we found that this result was only significant in the right-handed patients and in the smaller subgroup without drug use. In the right-handers, left eye dominance-like left-handedness-was associated with higher values in IMC and less pronounced manifestation of negative symptoms, right eye dominance was not. Thus, left-eyed right-handers may be more closely related to left-handers than to right-handers. In accordance with the results from the literature, we suggest that these findings are due to better interhemispheric connections and less impairment of white matter structures, especially in right-hemispheric regions. Moreover, cannabis use was related to higher scores in IMC and less pronounced negative symptoms, but only in the right-eyed and not in the left-eyed right-handers or in the left-handers. Hence, differences in eye dominance and handedness may be partially responsible for different results in interhemispheric connections among cannabis users. In conclusion, both eye dominance and use of cannabis should be taken into account when assessing clinical symptoms in schizophrenia patients.
Transfer of motor and perceptual skills from basketball to darts
Rienhoff, Rebecca; Hopwood, Melissa J.; Fischer, Lennart; Strauss, Bernd; Baker, Joseph; Schorer, Jörg
2013-01-01
The quiet eye is a perceptual skill associated with expertise and superior performance; however, little is known about the transfer of quiet eye across domains. We attempted to replicate previous skill-based differences in quiet eye and investigated whether transfer of motor and perceptual skills occurs between similar tasks. Throwing accuracy and quiet eye duration for skilled and less-skilled basketball players were examined in basketball free throw shooting and the transfer task of dart throwing. Skilled basketball players showed significantly higher throwing accuracy and longer quiet eye duration in the basketball free throw task compared to their less-skilled counterparts. Further, skilled basketball players showed positive transfer from basketball to dart throwing in accuracy but not in quiet eye duration. Our results raise interesting questions regarding the measurement of transfer between skills. PMID:24062703
Su, Luning; Li, Wei; Wu, Mingxuan; Su, Yun; Guo, Chongling; Ruan, Ningjuan; Yang, Bingxin; Yan, Feng
2017-08-01
Lobster-eye optics is widely applied to space x-ray detection missions and x-ray security checks for its wide field of view and low weight. This paper presents a theoretical model to obtain spatial distribution of focusing efficiency based on lobster-eye optics in a soft x-ray wavelength. The calculations reveal the competition mechanism of contributions to the focusing efficiency between the geometrical parameters of lobster-eye optics and the reflectivity of the iridium film. In addition, the focusing efficiency image depending on x-ray wavelengths further explains the influence of different geometrical parameters of lobster-eye optics and different soft x-ray wavelengths on focusing efficiency. These results could be beneficial to optimize parameters of lobster-eye optics in order to realize maximum focusing efficiency.
Mala, S.; Latha, K.
2014-01-01
Activity recognition is needed in different requisition, for example, reconnaissance system, patient monitoring, and human-computer interfaces. Feature selection plays an important role in activity recognition, data mining, and machine learning. In selecting subset of features, an efficient evolutionary algorithm Differential Evolution (DE), a very efficient optimizer, is used for finding informative features from eye movements using electrooculography (EOG). Many researchers use EOG signals in human-computer interactions with various computational intelligence methods to analyze eye movements. The proposed system involves analysis of EOG signals using clearness based features, minimum redundancy maximum relevance features, and Differential Evolution based features. This work concentrates more on the feature selection algorithm based on DE in order to improve the classification for faultless activity recognition. PMID:25574185
Mala, S; Latha, K
2014-01-01
Activity recognition is needed in different requisition, for example, reconnaissance system, patient monitoring, and human-computer interfaces. Feature selection plays an important role in activity recognition, data mining, and machine learning. In selecting subset of features, an efficient evolutionary algorithm Differential Evolution (DE), a very efficient optimizer, is used for finding informative features from eye movements using electrooculography (EOG). Many researchers use EOG signals in human-computer interactions with various computational intelligence methods to analyze eye movements. The proposed system involves analysis of EOG signals using clearness based features, minimum redundancy maximum relevance features, and Differential Evolution based features. This work concentrates more on the feature selection algorithm based on DE in order to improve the classification for faultless activity recognition.
Online webcam-based eye tracking in cognitive science: A first look.
Semmelmann, Kilian; Weigelt, Sarah
2018-04-01
Online experimentation is emerging in many areas of cognitive psychology as a viable alternative or supplement to classical in-lab experimentation. While performance- and reaction-time-based paradigms are covered in recent studies, one instrument of cognitive psychology has not received much attention up to now: eye tracking. In this study, we used JavaScript-based eye tracking algorithms recently made available by Papoutsaki et al. (International Joint Conference on Artificial Intelligence, 2016) together with consumer-grade webcams to investigate the potential of online eye tracking to benefit from the common advantages of online data conduction. We compared three in-lab conducted tasks (fixation, pursuit, and free viewing) with online-acquired data to analyze the spatial precision in the first two, and replicability of well-known gazing patterns in the third task. Our results indicate that in-lab data exhibit an offset of about 172 px (15% of screen size, 3.94° visual angle) in the fixation task, while online data is slightly less accurate (18% of screen size, 207 px), and shows higher variance. The same results were found for the pursuit task with a constant offset during the stimulus movement (211 px in-lab, 216 px online). In the free-viewing task, we were able to replicate the high attention attribution to eyes (28.25%) compared to other key regions like the nose (9.71%) and mouth (4.00%). Overall, we found web technology-based eye tracking to be suitable for all three tasks and are confident that the required hard- and software will be improved continuously for even more sophisticated experimental paradigms in all of cognitive psychology.
NASA Astrophysics Data System (ADS)
Xu, Jie; Wang, Xin; Mu, Baozhong; Zhan, Qi; Xie, Qing; Li, Yaran; Chen, Yifan; He, Yanan
2016-10-01
In order to counter drug-related crimes effectively, and to safeguard homeland security as well as public safety, it is important to inspect drugs, explosives and other contraband quickly and accurately from the express mail system, luggage, vehicles and other objects. In this paper, we discuss X-ray backscatter inspection system based on a novel lobster-eye X-ray objective, which is an effective inspection technology for drugs, explosives and other contraband inspection. Low atomic number materials, such as drugs and explosives, leads to strong Compton scattering after irradiated by X-ray, which is much stronger than high atomic number material, such as common metals, etc. By detecting the intensity of scattering signals, it is possible to distinguish between organics and inorganics. The lobster-eye X-ray optical system imitates the reflective eyes of lobsters, which field of view can be made as large as desired and it is practical to achieve spatial resolution of several millimeters for finite distance detection. A novel lobster-eye X-ray objective is designed based on modifying Schmidt geometry by using multi-lens structure, so as to reduce the difference of resolution between the horizontal and vertical directions. The demonstration experiments of X-ray backscattering imaging were carried out. A suitcase, a wooden box and a tire with several typical samples hidden in them were imaged by the X-ray backscattering inspection system based on a lobster-eye X-ray objective. The results show that this X-ray backscattering inspection system can get a resolution of less than five millimeters under the FOV of more than two hundred millimeters with 0.5 meter object distance, which can still be improved.
Insights into numerical cognition: considering eye-fixations in number processing and arithmetic.
Mock, J; Huber, S; Klein, E; Moeller, K
2016-05-01
Considering eye-fixation behavior is standard in reading research to investigate underlying cognitive processes. However, in numerical cognition research eye-tracking is used less often and less systematically. Nevertheless, we identified over 40 studies on this topic from the last 40 years with an increase of eye-tracking studies on numerical cognition during the last decade. Here, we review and discuss these empirical studies to evaluate the added value of eye-tracking for the investigation of number processing. Our literature review revealed that the way eye-fixation behavior is considered in numerical cognition research ranges from investigating basic perceptual aspects of processing non-symbolic and symbolic numbers, over assessing the common representational space of numbers and space, to evaluating the influence of characteristics of the base-10 place-value structure of Arabic numbers and executive control on number processing. Apart from basic results such as reading times of numbers increasing with their magnitude, studies revealed that number processing can influence domain-general processes such as attention shifting-but also the other way round. Domain-general processes such as cognitive control were found to affect number processing. In summary, eye-fixation behavior allows for new insights into both domain-specific and domain-general processes involved in number processing. Based thereon, a processing model of the temporal dynamics of numerical cognition is postulated, which distinguishes an early stage of stimulus-driven bottom-up processing from later more top-down controlled stages. Furthermore, perspectives for eye-tracking research in numerical cognition are discussed to emphasize the potential of this methodology for advancing our understanding of numerical cognition.
Gaps in Current Knowledge and Priorities for Future Research in Dry Eye.
Saldanha, Ian J; Dickersin, Kay; Hutfless, Susan T; Akpek, Esen K
2017-12-01
Dry eye, a common yet underrecognized and evolving field, has few recommended treatment algorithms, mostly based on expert consensus rather than robust research evidence. There are high costs associated with managing dry eye and conducting research to identify effective and safe long-term treatments. To support evidence-based management of dry eye, our purpose was to identify and prioritize important clinical research questions for future clinical research. We translated recommendations from the American Academy of Ophthalmology's 2013 Preferred Practice Patterns for dry eye into answerable clinical research questions about treatment effectiveness. Clinicians around the world who manage patients with dry eye rated each question's importance from 0 (not important) to 10 (very important) using a 2-round online Delphi survey. We considered questions as "important" if ≥75% of respondents assigned a rating of 6 or more in round 2. We mapped the identified important clinical research questions to reliable systematic reviews published up to March 2016. Seventy-five clinicians from at least 21 countries completed both Delphi rounds. Among the 58 questions, 24 met our definition of "important": 9/24 and 7/24 addressed topical and systemic treatments, respectively. All 4 questions with the highest 25th percentiles addressed topical treatments. Although 6/24 "important" questions were associated with 4 existing reliable systematic reviews, none of these reviews came to a definitive conclusion about treatment effectiveness. We identified gaps pertaining to treatment options for dry eye. Future clinical research on the management of dry eye should strongly consider these prioritized questions.
iPhone applications for eye care professionals: a review of current capabilities and concerns.
Cheng, Nicholas M; Chakrabarti, Rahul; Kam, Jonathan K
2014-04-01
To quantitatively review and categorize the eye care-related iPhone(®) (Apple(®), Cupertino, CA) applications ("apps") currently available, evaluate qualified professional involvement in app development, and suggest future needs in this emerging area of mobile health. The Apple iTunes(®) store was searched for iPhone eye care-themed apps using the general terms "ophthalmology," "ophthalmologist," "optometry," "optometrist," "eye care," and "ocular," in addition to terms based on the Centers for Disease Control and Prevention's common eye conditions. Data collected from each app included publication date, target audience, category of app, estimated number of downloads, average user rating, and documented involvement of qualified professionals. In total, 182 apps were identified. The majority of apps lacked community user ratings and had 3,000 or fewer downloads (84% and 69%, respectively). Consistent with other medical specialties, only 37% of apps had documented qualified professional involvement in their development. When stratified by intended audience, 52% and 44% of apps designed for ophthalmologists and optometrists, respectively, had professional input, compared with 31% for non-eye care clinicians and 21% for the general public. Smartphone apps are likely to become of increasingly greater relevance to the modern eye care professional with tremendous versatility in daily practice. However, despite the rapid emergence of eye care apps, a low level of qualified professional involvement in app development and a lack of peer review after publishing remain. There is a clear need for evidence-based principles and standards of app development to be adopted in this emerging area.
Doughty, Michael J
2017-07-01
The aim was to assess differences in eyeball mass, corneal diameter and central corneal thickness in slaughterhouse-procured ovine eyes. Over a 12-year period, measurements of eye globe mass, horizontal corneal diameter and central corneal thickness were routinely undertaken within two hours post-mortem. Only eyes free of obvious mechanical damage or disease were used. From measurements on 736 quality-selected and trimmed eyes, globe wet mass ranged from 10.4 to 25.2 g, horizontal corneal diameter from 19.0 to 26.5 mm and central corneal thickness measured by ultrasonic pachymetry from 0.543 to 0.836 mm (with an overall average of 690 ± 0.056 mm). The ocular globe mass was strongly correlated to horizontal corneal diameter (r 2 = 0.829). Central corneal thickness correlated with globe mass (r = 0.543) and to horizontal corneal diameter (r = 0.402). Based on the different anatomical measurements, a lamb's eye would be expected to have a thinner cornea (average 0.640 mm) than that of an adult outbred ewe (average 0.730 mm). In freshly procured eyes showing signs of slight corneal oedema, central corneal thickness was greater (average 0.856 ± 0.052 mm) and up to 24 hours of cold storage resulted in predictable increases in central corneal thickness of six to 24 per cent, especially in eyes showing signs of corneal oedema before storage. Based on the correlations obtained, differences in ovine eyes can be attributed to growth-related differences in the animals and thus, indirectly to their expected ages. A simple measure of the horizontal corneal diameter in ovine eyes used for laboratory studies would be a useful indicator in reporting these studies. © 2016 Optometry Australia.
Red eyes and red-flags: improving ophthalmic assessment and referral in primary care.
Kilduff, Caroline; Lois, Charis
2016-01-01
Up to five percent of primary care consultations are eye-related, yet 96% of General Practitioners (GPs) do not undergo postgraduate ophthalmology training. Most do not feel assured performing eye assessments. Some red eye conditions can become sight threatening, and often exhibit red-flag features. These features include moderate pain, photophobia, reduced visual acuity (VA), eye-trauma, or unilateral marked redness. The aim of this project was to improve primary care assessment and referral of patients presenting with red-flag features based on the NICE 'Red Eye' Clinical Knowledge Summary recommendations. Data was collected retrospectively from 139 red eye consultations. A practice meeting highlighted poor awareness of red-flag features, low confidence levels in eye assessments, and time-constraints during appointments. Interventions were based on feedback from staff. These included a primary care teaching session on red-flag features, a VA measurement tutorial, and provision of a red eye toolkit, including VA equipment, to each consultation room. At baseline, each patient had on average 0.9 red-flag features assessed. Only 36.0% (9/25) of patients with red-flag features were appropriately referred to same-day ophthalmology services. Following two improvement cycles, a significant improvement was seen in almost every parameter. On average, each patient had 2.7 red-flag features assessed (vs 0.9, p<0.001). VA was assessed in 55.6% of consultations (vs 7.9%, p<0.001), pain was quantified in 81.5% (vs 20.9%, p=0.005), eye-trauma or foreign-body (51.8% vs 8.6%, p<0.001), extent of redness was documented in 66.7% (vs 14.4%, p<0.001). Only photophobia remained poorly assessed (18.5% vs 14.4%, p=0.75). Following this, 75.0% (6/8) of patients were appropriately referred. This project reflected the literature regarding low confidence and inexperience amongst GPs when faced with ophthalmic conditions. Improvements in education are required to ensure accurate assessments can be undertaken in a time-constrained environment.
Chung, So-Hyang; Myong, Jun-Pyo
2016-04-27
The purpose of this study was to investigate whether blood mercury concentrations associated with the presence of dry eye symptoms in a nationally representative Korean population. Population-based prospective cross-sectional study using the heavy metal data set of the 2010-2012 Korean National Health and Nutrition Examination Survey (KNHANES). A total of 4761 adult Koreans were the eligible population in this study. Of the 7162 survey participants, 2401 were excluded because they were <19 years of age, there were missing data in the heavy metal data set, or they had diabetes, rheumatoid arthritis, thyroid disease, asthma, depression and/or under-the-eye surgery. Blood mercury levels were measured on the day the participants completed a questionnaire regarding the presence of dry eye symptoms (persistent dryness or eye irritation). The population was divided into low and high groups by median level (4.26 and 2.89 µg/L for males and females, respectively). Self-reported dry eye symptoms were present in 13.0% of the cohort. Participants with dry eye symptoms were significantly more likely to have blood mercury levels exceeding the median than those without dry eye symptoms (45.7% vs 51.7%, p=0.021). Logistic regression analysis showed that, after adjusting for age, gender, education, total household income, smoking status, heavy alcohol use, sleep time, perceived stress status, total cholesterol levels and atopy history, dry eye symptoms were significantly associated with blood mercury levels that exceeded the median (reference: lower mercury group; OR, 1.324; 95% CI 1.059 to 1.655; p<0.05). High blood mercury levels were associated with dry eye symptoms in a nationally representative Korean population. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Clinical effect of four different ointment bases on healthy cat eyes.
Eördögh, Réka; Schwendenwein, Ilse; Tichy, Alexander; Loncaric, Igor; Nell, Barbara
2016-07-01
To describe the effects of long-term treatment with four different eye ointment bases (OBs) in cats. Ten healthy cats. The study was performed in two periods. Four different OBs were tested. Hundred grams of OB contained the following: OB-A: 35.17 g liquid paraffin (lp), 64.83 g white petrolatum (wp); OB-B: 10.03 g lp, 84.95 g wp 5.02 g lanolin; OB-C: 18.34 g lp, 51.40 g wp, 25.00 mg KH2 PO4 , 57.00 mg K2 HPO4 , 18.90 g eucerinum anhydricum, 11.28 g water for injections; and OB-D: 70 g unguentum lanalcoli, 20 g lp, 10 g aqua conservans. One eye was treated, and the other served as a negative control. Cats received the OBs TID for 28 days. The two study periods were separated by a 4-month washout phase. Samples for conjunctival impression cytology, swabs for bacteriologic and mycologic examination, and cytobrush samples for FHV-1 and Chlamydophila felis PCR detection were obtained. Both eyes were examined daily. Severity of ocular symptoms was scored using a modified Draize eye irritation test. A total of five eyes were treated with OB-A, five with OB-B, four with OB-C, and five with OB-D. Treated eyes had significantly higher clinical scores. Eyes receiving OB-A had the highest overall clinical score. The results of bacteriologic and mycologic examination concur with the previously published data. All samples tested were negative for FHV-1 and Chlamydophila felis. There was no significant difference between treated and control eyes upon cytological examination. The application of OBs resulted in clinical symptoms in treated eyes. The long-term use of ointments is not well tolerated in cats and may lead to ocular irritation. © 2015 American College of Veterinary Ophthalmologists.
Rhodes, Lindsay A; Huisingh, Carrie E; McGwin, Gerald; Mennemeyer, Stephen T; Bregantini, Mary; Patel, Nita; Saaddine, Jinan; Crews, John E; Girkin, Christopher A; Owsley, Cynthia
2016-01-01
Purpose To assess the impact of the education program of the Eye Care Quality and Accessibility Improvement in the Community (EQUALITY) telemedicine program on at-risk patients’ knowledge about glaucoma and attitudes about eye care as well as to assess patient satisfaction with EQUALITY. Patients and methods New or existing patients presenting for a comprehensive eye exam (CEE) at one of two retail-based primary eye clinics were enrolled based on ≥1 of the following at-risk criteria for glaucoma: African Americans ≥40 years of age, Whites ≥50 years of age, diabetes, family history of glaucoma, and/or preexisting diagnosis of glaucoma. A total of 651 patients were enrolled. A questionnaire was administered prior to the patients’ CEE and prior to the patients receiving any of the evidence-based eye health education program; a follow-up questionnaire was administered 2–4 weeks later by phone. Baseline and follow-up patient responses regarding knowledge about glaucoma and attitudes about eye care were compared using McNemar’s test. Logistic regression models were used to assess the association of patient-level characteristics with improvement in knowledge and attitudes. Overall patient satisfaction was summarized. Results At follow-up, all patient responses in the knowledge and attitude domains significantly improved from baseline (P≤0.01 for all questions). Those who were unemployed (odds ratio =0.63, 95% confidence interval =0.42–0.95, P=0.026) or had lower education (odds ratio =0.55, 95% confidence interval =0.29–1.02, P=0.058) were less likely to improve their knowledge after adjusting for age, sex, race, and prior glaucoma diagnosis. This association was attenuated after further adjustment for other patient-level characteristics. Ninety-eight percent (n=501) of patients reported being likely to have a CEE within the next 2 years, whereas 63% (n=326) had a CEE in the previous 2 years. Patient satisfaction with EQUALITY was high (99%). Conclusion Improved knowledge about glaucoma and a high intent to pursue eye care may lead to improved detection of early disease, thus lowering the risk of blindness. PMID:27274329
Biosocial profile of New Zealand prosthetic eye wearers.
Pine, Keith R; Sloan, Brian; Jacobs, Robert J
2012-10-12
To describe the biosocial profile of New Zealand (NZ) artificial eye wearers and establish a basis for future research and international comparison. This retrospective study surveyed 431 NZ artificial eye wearers to investigate their ethnicity, gender, age, causes of eye loss, age of current prosthesis, ocular prosthetic maintenance regimes and the extent and severity of discharge associated with prosthesis wear. Approximately 3000 people wear artificial eyes in NZ. Accidents were the main cause of eye loss prior to 1990 and medical conditions have been the main cause since. In the 1960s, the ratio of men to women losing an eye from accidents was 5:1, but during the past decade the ratio was 1.4:1. Socket discharge occurred at least twice daily for one-third of the study group. Approximately 1 in 1440 people wear artificial eyes in NZ. Decline of eye loss due to accidents is consistent with decreasing workplace and traffic accidents and may be due to improved medical management, workplace safety standards and safer roads. Mucoid discharge is prevalent in the anophthalmic population of NZ and an evidence based treatment protocol for discharge associated with prosthesis wear is needed. Research into this distressing condition is planned.
Bio-inspired hemispherical compound eye camera
NASA Astrophysics Data System (ADS)
Xiao, Jianliang; Song, Young Min; Xie, Yizhu; Malyarchuk, Viktor; Jung, Inhwa; Choi, Ki-Joong; Liu, Zhuangjian; Park, Hyunsung; Lu, Chaofeng; Kim, Rak-Hwan; Li, Rui; Crozier, Kenneth B.; Huang, Yonggang; Rogers, John A.
2014-03-01
Compound eyes in arthropods demonstrate distinct imaging characteristics from human eyes, with wide angle field of view, low aberrations, high acuity to motion and infinite depth of field. Artificial imaging systems with similar geometries and properties are of great interest for many applications. However, the challenges in building such systems with hemispherical, compound apposition layouts cannot be met through established planar sensor technologies and conventional optics. We present our recent progress in combining optics, materials, mechanics and integration schemes to build fully functional artificial compound eye cameras. Nearly full hemispherical shapes (about 160 degrees) with densely packed artificial ommatidia were realized. The number of ommatidia (180) is comparable to those of the eyes of fire ants and bark beetles. The devices combine elastomeric compound optical elements with deformable arrays of thin silicon photodetectors, which were fabricated in the planar geometries and then integrated and elastically transformed to hemispherical shapes. Imaging results and quantitative ray-tracing-based simulations illustrate key features of operation. These general strategies seem to be applicable to other compound eye devices, such as those inspired by moths and lacewings (refracting superposition eyes), lobster and shrimp (reflecting superposition eyes), and houseflies (neural superposition eyes).
Thermal fluctuation based study of aqueous deficient dry eyes by non-invasive thermal imaging.
Azharuddin, Mohammad; Bera, Sumanta Kr; Datta, Himadri; Dasgupta, Anjan Kr
2014-03-01
In this paper we have studied the thermal fluctuation patterns occurring at the ocular surface of the left and right eyes for aqueous deficient dry eye (ADDE) patients and control subjects by thermal imaging. We conducted our experiment on 42 patients (84 eyes) with aqueous deficient dry eyes and compared with 36 healthy volunteers (72 eyes) without any history of ocular surface disorder. Schirmer's test, Tear Break-up Time, tear Meniscus height and fluorescein staining tests were conducted. Ocular surface temperature measurement was done, using an FL-IR thermal camera and thermal fluctuation in left and right eyes was calculated and analyzed using MATLAB. The time series containing the sum of squares of the temperature fluctuation on the ocular surface were compared for aqueous deficient dry eye and control subjects. Significant statistical difference between the fluctuation patterns for control and ADDE was observed (p < 0.001 at 95% confidence interval). Thermal fluctuations in left and right eyes are significantly correlated in controls but not in ADDE subjects. The possible origin of such correlation in control and lack of correlation in the ADDE subjects is discussed in the text. Copyright © 2014 Elsevier Ltd. All rights reserved.
Tsubota, Kazuo; Yokoi, Norihiko; Shimazaki, Jun; Watanabe, Hitoshi; Dogru, Murat; Yamada, Masakazu; Kinoshita, Shigeru; Kim, Hyo-Myung; Tchah, Hung-Won; Hyon, Joon Young; Yoon, Kyung-Chul; Seo, Kyoung Yul; Sun, Xuguang; Chen, Wei; Liang, Lingyi; Li, Mingwu; Liu, Zuguo
2017-01-01
For the last 20 years, a great amount of evidence has accumulated through epidemiological studies that most of the dry eye disease encountered in daily life, especially in video display terminal (VDT) workers, involves short tear film breakup time (TFBUT) type dry eye, a category characterized by severe symptoms but minimal clinical signs other than short TFBUT. An unstable tear film also affects the visual function, possibly due to the increase of higher order aberrations. Based on the change in the understanding of the types, symptoms, and signs of dry eye disease, the Asia Dry Eye Society agreed to the following definition of dry eye: "Dry eye is a multifactorial disease characterized by unstable tear film causing a variety of symptoms and/or visual impairment, potentially accompanied by ocular surface damage." The definition stresses instability of the tear film as well as the importance of visual impairment, highlighting an essential role for TFBUT assessment. This paper discusses the concept of Tear Film Oriented Therapy (TFOT), which evolved from the definition of dry eye, emphasizing the importance of a stable tear film. Copyright © 2016 The Author(s). Published by Elsevier Inc. All rights reserved.
Wang, Xiu; Lu, Xiaoxiao; Yang, Jun; Wei, Ruihua; Yang, Liyuan; Zhao, Shaozhen; Wang, Xilian
2016-01-01
Purpose. This study aims to evaluate dry eye and ocular surface conditions of myopic teenagers by using questionnaire and clinical examinations. Methods. A total of 496 eyes from 248 myopic teenagers (7–18 years old) were studied. We administered Ocular Surface Disease Index (OSDI) questionnaire, slit-lamp examination, and Keratograph 5M. The patients were divided into 2 groups based on OSDI dry eye standard, and their ocular surfaces and meibomian gland conditions were evaluated. Results. The tear meniscus heights of the dry eye and normal groups were in normal range. Corneal fluorescein scores were significantly higher whereas noninvasive break-up time was dramatically shorter in the dry eye group than in the normal group. All three meibomian gland dysfunction parameters (i.e., meibomian gland orifice scores, meibomian gland secretion scores, and meibomian gland dropout scores) of the dry eye group were significantly higher than those of the normal group (P < 0.0001). Conclusions. The prevalence of dry eye in myopic teenagers is 18.95%. Meibomian gland dysfunction plays an important role in dry eye in myopic teenagers. The Keratograph 5M appears to provide an effective noninvasive method for assessing ocular surface situation of myopic teenagers. PMID:26881059
Specialized moisture retention eyewear for evaporative dry eye.
Waduthantri, Samanthila; Tan, Chien Hua; Fong, Yee Wei; Tong, Louis
2015-05-01
To evaluate the suitablity of commercially available moisture retention eyewear for treating evaporative dry eye. Eleven patients with evaporative dry eyes were prescibed moisture retention eyewear for 3 months in addition to regular lubricant eye drops. Frequency and severity of dry eye symptoms, corneal fluorescein staining and tear break up time (TBUT) were evaluated at baseline and 3-month post-treatment. Main outcome measure was global symptom score (based on severity and frequency of dry eye symptoms on a visual analog scale) and secondary outcomes were changes in sectoral corneal fluorescein staining and tear break up time (TBUT) from pre-treatment level. There was a significant improvement in dry eye symptoms after using moisture retention eyewear for 3 months (p < 0.05). Corneal fluorescein staining in all five zones of the cornea in both eyes improved significantly (p < 0.05). There was no significant improvement in TBUT. Patients used ocular lubricants less frequently (p < 0.05) compared to the commencement of the study. Patients found moisture retention eyewear to be useful in relieving dry eye symptoms in windy, air-conditioned environments or when doing vision-related daily tasks. This study shows that moisture retention eyewear might be a valuable adjunct in management of evaporative dry eye and this new design of commercially available eyewear could have a good acceptability rate.
Neural mechanisms of eye contact when listening to another person talking.
Jiang, Jing; Borowiak, Kamila; Tudge, Luke; Otto, Carolin; von Kriegstein, Katharina
2017-02-01
Eye contact occurs frequently and voluntarily during face-to-face verbal communication. However, the neural mechanisms underlying eye contact when it is accompanied by spoken language remain unexplored to date. Here we used a novel approach, fixation-based event-related functional magnetic resonance imaging (fMRI), to simulate the listener making eye contact with a speaker during verbal communication. Participants' eye movements and fMRI data were recorded simultaneously while they were freely viewing a pre-recorded speaker talking. The eye tracking data were then used to define events for the fMRI analyses. The results showed that eye contact in contrast to mouth fixation involved visual cortical areas (cuneus, calcarine sulcus), brain regions related to theory of mind/intentionality processing (temporoparietal junction, posterior superior temporal sulcus, medial prefrontal cortex) and the dorsolateral prefrontal cortex. In addition, increased effective connectivity was found between these regions for eye contact in contrast to mouth fixations. The results provide first evidence for neural mechanisms underlying eye contact when watching and listening to another person talking. The network we found might be well suited for processing the intentions of communication partners during eye contact in verbal communication. © The Author (2016). Published by Oxford University Press. For Permissions, please email: journals.permissions@oup.com.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lv, Yang; Wang, Ruixing; Ma, Haotong
Purpose: The measurement based on Shack-Hartmann wave-front sensor(WFS), obtaining both the high and low order wave-front aberrations simultaneously and accurately, has been applied in the detection of human eyes aberration in recent years. However, Its application is limited by the small field of view (FOV), slight eye movement leads the optical bacon image exceeds the lenslet array which result in uncertain detection error. To overcome difficulties of precise eye location, the capacity of detecting eye wave-front aberration over FOV much larger than simply a single conjugate Hartmann WFS accurately and simultaneously is demanded. Methods: Plenoptic camera’s lenslet array subdivides themore » aperture light-field in spatial frequency domain, capture the 4-D light-field information. Data recorded by plenoptic cameras can be used to extract the wave-front phases associated to the eyes aberration. The corresponding theoretical model and simulation system is built up in this article to discuss wave-front measurement performance when utilizing plenoptic camera as wave-front sensor. Results: The simulation results indicate that the plenoptic wave-front method can obtain both the high and low order eyes wave-front aberration with the same accuracy as conventional system in single visual angle detectionand over FOV much larger than simply a single conjugate Hartmann systems. Meanwhile, simulation results show that detection of eye aberrations wave-front in different visual angle can be achieved effectively and simultaneously by plenoptic method, by both point and extended optical beacon from the eye. Conclusion: Plenoptic wave-front method possesses the feasibility in eye aberrations wave-front detection. With larger FOV, the method can effectively reduce the detection error brought by imprecise eye location and simplify the eye aberrations wave-front detection system comparing with which based on Shack-Hartmann WFS. Unique advantage of the plenoptic method lies in obtaining wave-front in different visual angle simultaneously, which provides an approach in building up 3-D model of eye refractor tomographically. Funded by the key Laboratory of High Power Laser and Physics, CAS Research Project of National University of Defense Technology No. JC13-07-01; National Natural Science Foundation of China No. 61205144.« less
Yang, Yushi
2015-01-01
Background Eye-tracking technology has been used to measure human cognitive processes and has the potential to improve the usability of health information technology (HIT). However, it is still unclear how the eye-tracking method can be integrated with other traditional usability methodologies to achieve its full potential. Objective The objective of this study was to report on HIT evaluation studies that have used eye-tracker technology, and to envision the potential use of eye-tracking technology in future research. Methods We used four reference databases to initially identify 5248 related papers, which resulted in only 9 articles that met our inclusion criteria. Results Eye-tracking technology was useful in finding usability problems in many ways, but is still in its infancy for HIT usability evaluation. Limited types of HITs have been evaluated by eye trackers, and there has been a lack of evaluation research in natural settings. Conclusions More research should be done in natural settings to discover the real contextual-based usability problems of clinical and mobile HITs using eye-tracking technology with more standardized methodologies and guidance. PMID:27026079
Ohuchi, Hideyo
2013-01-01
A central issue of evolutionary developmental biology is how the eye is diverged morphologically and functionally. However, the unifying mechanisms or schemes that govern eye diversification remain unsolved. In this review, I first introduce the concept of evolutionary developmental biology of the eye with a focus on photoreception, the fundamental property of retinal cells. Second, I summarize the early development of vertebrate eyes and the role of a homeobox gene, Lhx1, in subdivision of the retina into 2 domains, the neural retina and retinal pigmented epithelium of the optic primordium. The 2 retinal domains are essential components of the eye as they are found in such prototypic eyes as the extant planarian eye. Finally, I propose the presence of novel retinal cell subtypes with photosensory functions based on our recent work on atypical photopigments (opsins) in vertebrates. Since human diseases are attributable to the aberration of various types of cells due to alterations in gene expression, understanding the precise mechanisms of cellular diversification and unraveling the molecular profiles of cellular subtypes are essential to future regenerative medicine.
Live Speech Driven Head-and-Eye Motion Generators.
Le, Binh H; Ma, Xiaohan; Deng, Zhigang
2012-11-01
This paper describes a fully automated framework to generate realistic head motion, eye gaze, and eyelid motion simultaneously based on live (or recorded) speech input. Its central idea is to learn separate yet interrelated statistical models for each component (head motion, gaze, or eyelid motion) from a prerecorded facial motion data set: 1) Gaussian Mixture Models and gradient descent optimization algorithm are employed to generate head motion from speech features; 2) Nonlinear Dynamic Canonical Correlation Analysis model is used to synthesize eye gaze from head motion and speech features, and 3) nonnegative linear regression is used to model voluntary eye lid motion and log-normal distribution is used to describe involuntary eye blinks. Several user studies are conducted to evaluate the effectiveness of the proposed speech-driven head and eye motion generator using the well-established paired comparison methodology. Our evaluation results clearly show that this approach can significantly outperform the state-of-the-art head and eye motion generation algorithms. In addition, a novel mocap+video hybrid data acquisition technique is introduced to record high-fidelity head movement, eye gaze, and eyelid motion simultaneously.
The role of eye protection in work-related eye injuries.
Fong, L P; Taouk, Y
1995-05-01
A recent survey of general hospitals by the Victorian Injury Surveillance System found that ocular trauma represented 15% of work-related injuries. As circumstances surrounding occupational eye injuries have been poorly documented previously, their associations to occupation, industry and work-safety practices, including safety eyewear use, need to be identified to develop appropriate preventive strategies for high-risk groups. From a prospective cross-sectional survey of all eye injuries treated at the Royal Victorian Eye and Ear Hospital, work-related cases were analysed for demographic, occupational and safety eye-wear information. Hospital-based data were supplemented by information from WorkCover Authorities and Labour Force statistics to derive incidence and cost estimates. There were 9390 eye injuries during the 18-month survey period; 42% (n=3923) of total and 29% (n=52) of penetrating ocular injuries occurred at work. The most frequently injured were metal, automotive and building trades workers grinding and drilling (41% of outpatients) and hammering (53% of penetrating eye injuries). Automotive workers had the highest frequency for penetrating injuries, and most were exposed to hammering and were also the least likely to wear safety eye-wear. Eye injuries are frequent (10% of work-related injuries) and highly preventable by the correct use of safety eye-wear, a cost-effective intervention that may result in cost savings of $59 million for work-type activities in the occupational and domestic settings in Australia each year.
A holographic waveguide based eye tracker
NASA Astrophysics Data System (ADS)
Liu, Changgeng; Pazzucconi, Beatrice; Liu, Juan; Liu, Lei; Yao, Xincheng
2018-02-01
We demonstrated the feasibility of using holographic waveguide for eye tracking. A custom-built holographic waveguide, a 20 mm x 60 mm x 3 mm flat glass substrate with integrated in- and out-couplers, was used for the prototype development. The in- and out-couplers, photopolymer films with holographic fringes, induced total internal reflection in the glass substrate. Diffractive optical elements were integrated into the in-coupler to serve as an optical collimator. The waveguide captured images of the anterior segment of the eye right in front of it and guided the images to a processing unit distant from the eye. The vector connecting the pupil center (PC) and the corneal reflex (CR) of the eye was used to compute eye position in the socket. An eye model, made of a high quality prosthetic eye, was used prototype validation. The benchtop prototype demonstrated a linear relationship between the angular eye position and the PC/CR vector over a range of 60 horizontal degrees and 30 vertical degrees at a resolution of 0.64-0.69 degrees/pixel by simple pixel count. The uncertainties of the measurements at different angular positions were within 1.2 pixels, which indicated that the prototype exhibited a high level of repeatability. These results confirmed that the holographic waveguide technology could be a feasible platform for developing a wearable eye tracker. Further development can lead to a compact, see-through eye tracker, which allows continuous monitoring of eye movement during real life tasks, and thus benefits diagnosis of oculomotor disorders.
A Clinic-based Survey of Clinical Characteristics and Practice Pattern of Dry Eye in Japan.
Kawashima, Motoko; Yamada, Masakazu; Suwaki, Kazuhisa; Shigeyasu, Chika; Uchino, Miki; Hiratsuka, Yoshimune; Yokoi, Norihiko; Tsubota, Kazuo
2017-03-01
The aim of this study was to investigate the clinical characteristics and practice pattern of patients with dry eye disease (DED) in eye clinics across Japan. A multi-center, cross-sectional study was conducted among patients with DED who visited eye clinics in Japan. Subjective symptoms, patient's background, ocular surface features, and tear function were evaluated. Main outcome measures were tear break-up time (TBUT), Schirmer I value, kerato-conjunctival staining score, and dry eye symptom questionnaire score. Initially, 463 subjects were enrolled, and 449 cases (63 male and 386 female; mean age, 62.6 ± 15.7 years) were included in the final analysis. Overall, 94.9% of patients had a shortened TBUT (≤5 s), and 54.6% had an aqueous tear deficiency (Schirmer I value ≤5 mm). The most prevalent subtype of dry eye was aqueous-deficient dry eye, which was present in 35.0% of all patients, followed by short-BUT-type dry eye, which was seen in 26.7%. The two most common DED subtypes were aqueous-deficient and short-BUT-type dry eye. Shortened TBUT is the most common feature of dry eye, regardless of subtype. The current treatment choice mainly consisted of hyaluronic acid, two novel mucin secretagogues, diquafosol and rebamipide, and steroidal eye drops. University Hospital Medical Information Network: UMIN (registries no. UMIN 000015890). Japan Dry Eye Society, Tokyo, Japan, and Santen Pharmaceutical Co., Ltd., Osaka, Japan.
Audo, Denis; Haug, Joachim T; Haug, Carolin; Charbonnier, Sylvain; Schweigert, Günter; Müller, Carsten H G; Harzsch, Steffen
2016-01-01
Modern representatives of Polychelida (Polychelidae) are considered to be entirely blind and have largely reduced eyes, possibly as an adaptation to deep-sea environments. Fossil species of Polychelida, however, appear to have well-developed compound eyes preserved as anterior bulges with distinct sculpturation. We documented the shapes and sizes of eyes and ommatidia based upon exceptionally preserved fossil polychelidans from Binton (Hettangian, United-Kingdom), Osteno (Sinemurian, Italy), Posidonia Shale (Toarcian, Germany), La Voulte-sur-Rhône (Callovian, France), and Solnhofen-type plattenkalks (Kimmeridgian-Tithonian, Germany). For purposes of comparison, sizes of the eyes of several other polychelidans without preserved ommatidia were documented. Sizes of ommatidia and eyes were statistically compared against carapace length, taxonomic group, and outcrop. Nine species possess eyes with square facets; Rosenfeldia oppeli (Woodward, 1866), however, displays hexagonal facets. The sizes of eyes and ommatidia are a function of carapace length. No significant differences were discerned between polychelidans from different outcrops; Eryonidae, however, have significantly smaller eyes than other groups. Fossil eyes bearing square facets are similar to the reflective superposition eyes found in many extant decapods. As such, they are the earliest example of superposition eyes. As reflective superposition is considered plesiomorphic for Reptantia, this optic type was probably retained in Polychelida. The two smallest specimens, a Palaeopentacheles roettenbacheri (Münster, 1839) and a Hellerocaris falloti (Van Straelen, 1923), are interpreted as juveniles. Both possess square-shaped facets, a typical post-larval feature. The eye morphology of these small specimens, which are far smaller than many extant eryoneicus larvae, suggests that Jurassic polychelidans did not develop via giant eryoneicus larvae. In contrast, another species we examined, Rosenfeldia oppeli (Woodward, 1866), did not possess square-shaped facets, but rather hexagonal ones, which suggests that this species did not possess reflective superposition eyes. The hexagonal facets may indicate either another type of superposition eye (refractive or parabolic superposition), or an apposition eye. As decapod larvae possess apposition eyes with hexagonal facets, it is most parsimonious to consider eyes of R. oppeli as apposition eyes evolved through paedomorphic heterochrony. Polychelidan probably originally had reflective superposition. R. oppeli, however, probably gained apposition eyes through paedomorphosis.
Dobson, Nicola; De Grave, Sammy
2015-01-01
Most caridean decapods have compound eyes of the reflecting superposition kind, and additionally some possess an accessory eye-like organ of unknown function, also referred to as the nebenauge. We examined 308 caridean genera to assess the general morphology of the eye, rostrum length, eye diameter and the presence or absence and, when present, the diameter of the nebenauge. We have attempted to relate these data to ecological and taxonomic considerations. We consider there to be 6 distinct eye types based on the margin between the eyestalk and cornea. The presence of nebenaugen appears to be generally linked to an active lifestyle, as evidenced by the fact that species that have nebenaugen tend to have larger eyes and are more likely to have a distinct rostrum. We suggest that the inconsistencies in its presence/absence under both systematic and ecological lenses may indicate that when present it has various roles relating to behavioural and physiological rhythms. PMID:26312177
A binocular approach to treating amblyopia: antisuppression therapy.
Hess, Robert F; Mansouri, Behzad; Thompson, Benjamin
2010-09-01
We developed a binocular treatment for amblyopia based on antisuppression therapy. A novel procedure is outlined for measuring the extent to which the fixing eye suppresses the fellow amblyopic eye. We hypothesize that suppression renders a structurally binocular system, functionally monocular. We demonstrate using three strabismic amblyopes that information can be combined normally between their eyes under viewing conditions where suppression is reduced. Also, we show that prolonged periods of viewing (under the artificial conditions of stimuli of different contrast in each eye) during which information from the two eyes is combined leads to a strengthening of binocular vision in such cases and eventual combination of binocular information under natural viewing conditions (stimuli of the same contrast in each eye). Concomitant improvement in monocular acuity of the amblyopic eye occurs with this reduction in suppression and strengthening of binocular fusion. Furthermore, in each of the three cases, stereoscopic function is established. This provides the basis for a new treatment of amblyopia, one that is purely binocular and aimed at reducing suppression as a first step.
Gender Classification Based on Eye Movements: A Processing Effect During Passive Face Viewing
Sammaknejad, Negar; Pouretemad, Hamidreza; Eslahchi, Changiz; Salahirad, Alireza; Alinejad, Ashkan
2017-01-01
Studies have revealed superior face recognition skills in females, partially due to their different eye movement strategies when encoding faces. In the current study, we utilized these slight but important differences and proposed a model that estimates the gender of the viewers and classifies them into two subgroups, males and females. An eye tracker recorded participant’s eye movements while they viewed images of faces. Regions of interest (ROIs) were defined for each face. Results showed that the gender dissimilarity in eye movements was not due to differences in frequency of fixations in the ROI s per se. Instead, it was caused by dissimilarity in saccade paths between the ROIs. The difference enhanced when saccades were towards the eyes. Females showed significant increase in transitions from other ROI s to the eyes. Consequently, the extraction of temporal transient information of saccade paths through a transition probability matrix, similar to a first order Markov chain model, significantly improved the accuracy of the gender classification results. PMID:29071007
Gender Classification Based on Eye Movements: A Processing Effect During Passive Face Viewing.
Sammaknejad, Negar; Pouretemad, Hamidreza; Eslahchi, Changiz; Salahirad, Alireza; Alinejad, Ashkan
2017-01-01
Studies have revealed superior face recognition skills in females, partially due to their different eye movement strategies when encoding faces. In the current study, we utilized these slight but important differences and proposed a model that estimates the gender of the viewers and classifies them into two subgroups, males and females. An eye tracker recorded participant's eye movements while they viewed images of faces. Regions of interest (ROIs) were defined for each face. Results showed that the gender dissimilarity in eye movements was not due to differences in frequency of fixations in the ROI s per se. Instead, it was caused by dissimilarity in saccade paths between the ROIs. The difference enhanced when saccades were towards the eyes. Females showed significant increase in transitions from other ROI s to the eyes. Consequently, the extraction of temporal transient information of saccade paths through a transition probability matrix, similar to a first order Markov chain model, significantly improved the accuracy of the gender classification results.
[Virtual reality in ophthalmological education].
Wagner, C; Schill, M; Hennen, M; Männer, R; Jendritza, B; Knorz, M C; Bender, H J
2001-04-01
We present a computer-based medical training workstation for the simulation of intraocular eye surgery. The surgeon manipulates two original instruments inside a mechanical model of the eye. The instrument positions are tracked by CCD cameras and monitored by a PC which renders the scenery using a computer-graphic model of the eye and the instruments. The simulator incorporates a model of the operation table, a mechanical eye, three CCD cameras for the position tracking, the stereo display, and a computer. The three cameras are mounted under the operation table from where they can observe the interior of the mechanical eye. Using small markers the cameras recognize the instruments and the eye. Their position and orientation in space is determined by stereoscopic back projection. The simulation runs with more than 20 frames per second and provides a realistic impression of the surgery. It includes the cold light source which can be moved inside the eye and the shadow of the instruments on the retina which is important for navigational purposes.
3D ocular ultrasound using gaze tracking on the contralateral eye: a feasibility study.
Afsham, Narges; Najafi, Mohammad; Abolmaesumi, Purang; Rohling, Robert
2011-01-01
A gaze-deviated examination of the eye with a 2D ultrasound transducer is a common and informative ophthalmic test; however, the complex task of the pose estimation of the ultrasound images relative to the eye affects 3D interpretation. To tackle this challenge, a novel system for 3D image reconstruction based on gaze tracking of the contralateral eye has been proposed. The gaze fixates on several target points and, for each fixation, the pose of the examined eye is inferred from the gaze tracking. A single camera system has been developed for pose estimation combined with subject-specific parameter identification. The ultrasound images are then transformed to the coordinate system of the examined eye to create a 3D volume. Accuracy of the proposed gaze tracking system and the pose estimation of the eye have been validated in a set of experiments. Overall system error, including pose estimation and calibration, are 3.12 mm and 4.68 degrees.
NASA Astrophysics Data System (ADS)
Tera, Akemi; Shirai, Kiyoaki; Yuizono, Takaya; Sugiyama, Kozo
In order to investigate reading processes of Japanese language learners, we have conducted an experiment to record eye movements during Japanese text reading using an eye-tracking system. We showed that Japanese native speakers use “forward and backward jumping eye movements” frequently[13],[14]. In this paper, we analyzed further the same eye tracking data. Our goal is to examine whether Japanese learners fix their eye movements at boundaries of linguistic units such as words, phrases or clauses when they start or end “backward jumping”. We consider conventional linguistic boundaries as well as boundaries empirically defined based on the entropy of the N-gram model. Another goal is to examine the relation between the entropy of the N-gram model and the depth of syntactic structures of sentences. Our analysis shows that (1) Japanese learners often fix their eyes at linguistic boundaries, (2) the average of the entropy is the greatest at the fifth depth of syntactic structures.
Early sensitivity for eyes within faces: a new neuronal account of holistic and featural processing
Nemrodov, Dan; Anderson, Thomas; Preston, Frank F.; Itier, Roxane J.
2017-01-01
Eyes are central to face processing however their role in early face encoding as reflected by the N170 ERP component is unclear. Using eye tracking to enforce fixation on specific facial features, we found that the N170 was larger for fixation on the eyes compared to fixation on the forehead, nasion, nose or mouth, which all yielded similar amplitudes. This eye sensitivity was seen in both upright and inverted faces and was lost in eyeless faces, demonstrating it was due to the presence of eyes at fovea. Upright eyeless faces elicited largest N170 at nose fixation. Importantly, the N170 face inversion effect (FIE) was strongly attenuated in eyeless faces when fixation was on the eyes but was less attenuated for nose fixation and was normal when fixation was on the mouth. These results suggest the impact of eye removal on the N170 FIE is a function of the angular distance between the fixated feature and the eye location. We propose the Lateral Inhibition, Face Template and Eye Detector based (LIFTED) model which accounts for all the present N170 results including the FIE and its interaction with eye removal. Although eyes elicit the largest N170 response, reflecting the activity of an eye detector, the processing of upright faces is holistic and entails an inhibitory mechanism from neurons coding parafoveal information onto neurons coding foveal information. The LIFTED model provides a neuronal account of holistic and featural processing involved in upright and inverted faces and offers precise predictions for further testing. PMID:24768932
Mobile Apps for Eye Care in Canada: An Analysis of the iTunes Store.
Rodin, Alexander; Shachak, Aviv; Miller, Aaron; Akopyan, Vladimir; Semenova, Nataliya
2017-06-14
Mobile phone screens can facilitate stimulation to various components of the visual system and many mobile apps are accepted as a means of providing clinical assessments for the oculo-visual system. Although many of these apps are intended for use in clinical settings, there is a growing number of apps in eye care developed for self-tests and eye exercises for lay people. These and other features, however, have not yet been well described. Our objective was to identify, describe, and categorize mobile apps related to eye care that are available to users in the Canadian iTunes market. We conducted an extensive search of the Apple iTunes Store for apps related to eye care. We used the terms "eye," "eye care," "vision," and "eye test" and included apps that are targeted at both lay people and medical professionals. We excluded apps whose primary function is not related to eye care. Eligible apps were categorized by primary purpose, based on how they were described by their developers in the iTunes Store. Our search yielded 10,657 apps, of which 427 met our inclusion criteria. After removing duplicates, 355 unique apps were subject to further review. We assigned the eligible apps to three distinct categories: 39/355 apps (11.0%) were intended for use by medical professionals, 236 apps (66.5%, 236/355) were intended for use by lay people, and 80 apps (22.5%, 80/355) were intended for marketing eye care and eye-care products. We identified 9 subcategories of apps based on the descriptions of their primary functions. Apps for medical professionals fell into three subcategories: clinical calculators (n=6), clinical diagnostic tools (n=18), and education and networking apps for professionals (n=15). Apps for lay people fell into four subcategories: self-testing (n=153), eye exercises (n=30), patient tools and low vision aids (n=35), and apps for patient education (n=18). Mixed-use apps (n=80) were placed into two subcategories: marketing of individual practitioners or eye-care products (n=72) and marketing of multiple eye-care products or professional services. The most extensive subcategory pertaining to eye care consisted of apps for use by lay people, especially for conducting self-tests (n=236). This study revealed a previously uncharacterized category of apps intended for use by doctors and patients, of which the primary goal is marketing of eye-care services and products (n=80). ©Alexander Rodin, Aviv Shachak, Aaron Miller, Vladimir Akopyan, Nataliya Semenova. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 14.06.2017.
Wu, Shang-Lin; Liao, Lun-De; Lu, Shao-Wei; Jiang, Wei-Ling; Chen, Shi-An; Lin, Chin-Teng
2013-08-01
Electrooculography (EOG) signals can be used to control human-computer interface (HCI) systems, if properly classified. The ability to measure and process these signals may help HCI users to overcome many of the physical limitations and inconveniences in daily life. However, there are currently no effective multidirectional classification methods for monitoring eye movements. Here, we describe a classification method used in a wireless EOG-based HCI device for detecting eye movements in eight directions. This device includes wireless EOG signal acquisition components, wet electrodes and an EOG signal classification algorithm. The EOG classification algorithm is based on extracting features from the electrical signals corresponding to eight directions of eye movement (up, down, left, right, up-left, down-left, up-right, and down-right) and blinking. The recognition and processing of these eight different features were achieved in real-life conditions, demonstrating that this device can reliably measure the features of EOG signals. This system and its classification procedure provide an effective method for identifying eye movements. Additionally, it may be applied to study eye functions in real-life conditions in the near future.
Panerai, Simonetta; Tasca, Domenica; Lanuzza, Bartolo; Trubia, Grazia; Ferri, Raffaele; Musso, Sabrina; Alagona, Giovanna; Di Guardo, Giuseppe; Barone, Concetta; Gaglione, Maria P; Elia, Maurizio
2014-08-01
This report, based on four studies with children with low-functioning autism, aimed at evaluating the effects of repetitive transcranial magnetic stimulation delivered on the left and right premotor cortices on eye-hand integration tasks; defining the long-lasting effects of high-frequency repetitive transcranial magnetic stimulation; and investigating the real efficacy of high-frequency repetitive transcranial magnetic stimulation by comparing three kinds of treatments (high-frequency repetitive transcranial magnetic stimulation, a traditional eye-hand integration training, and both treatments combined). Results showed a significant increase in eye-hand performances only when high-frequency repetitive transcranial magnetic stimulation was delivered on the left premotor cortex; a persistent improvement up to 1 h after the end of the stimulation; better outcomes in the treatment combining high-frequency repetitive transcranial magnetic stimulation and eye-hand integration training. Based on these preliminary findings, further evaluations on the usefulness of high-frequency repetitive transcranial magnetic stimulation in rehabilitation of children with autism are strongly recommended. © The Author(s) 2013.
Maeng, Sung Jun; Kim, Jinhwan; Cho, Gyuseong
2018-03-15
ICRP (2011) revised the dose limit to the eye lens to 20 mSv/y based on a recent epidemiological study of radiation-induced cataracts. Maintenance of steam generators at nuclear power plants is one of the highest radiation-associated tasks within a non-uniform radiation field. This study aims to evaluate eye lens doses in the steam generators of the Korean OPR1000 design. The source term was characterized based on the CRUD-specific activity, and both the eye lens dose and organ dose were simulated using MCNP6 combined with an ICRP voxel phantom and a mesh phantom, respectively. The eye lens dose was determined to be 5.39E-02-9.43E-02 Sv/h, with a negligible effect by beta particles. As the effective dose was found to be 0.81-1.21 times the lens equivalent dose depending on the phantom angles, the former can be used to estimate the lens dose in the SG of the OPR1000 for radiation monitoring purposes.
Mannan, Malik M Naeem; Kim, Shinjung; Jeong, Myung Yung; Kamran, M Ahmad
2016-02-19
Contamination of eye movement and blink artifacts in Electroencephalogram (EEG) recording makes the analysis of EEG data more difficult and could result in mislead findings. Efficient removal of these artifacts from EEG data is an essential step in improving classification accuracy to develop the brain-computer interface (BCI). In this paper, we proposed an automatic framework based on independent component analysis (ICA) and system identification to identify and remove ocular artifacts from EEG data by using hybrid EEG and eye tracker system. The performance of the proposed algorithm is illustrated using experimental and standard EEG datasets. The proposed algorithm not only removes the ocular artifacts from artifactual zone but also preserves the neuronal activity related EEG signals in non-artifactual zone. The comparison with the two state-of-the-art techniques namely ADJUST based ICA and REGICA reveals the significant improved performance of the proposed algorithm for removing eye movement and blink artifacts from EEG data. Additionally, results demonstrate that the proposed algorithm can achieve lower relative error and higher mutual information values between corrected EEG and artifact-free EEG data.
Near-to-eye electroholography via guided-wave acousto-optics for augmented reality
NASA Astrophysics Data System (ADS)
Jolly, Sundeep; Savidis, Nickolaos; Datta, Bianca; Smalley, Daniel; Bove, V. Michael
2017-03-01
Near-to-eye holographic displays act to directly project wavefronts into a viewer's eye in order to recreate 3-D scenes for augmented or virtual reality applications. Recently, several solutions for near-to-eye electroholography have been proposed based on digital spatial light modulators in conjunction with supporting optics, such as holographic waveguides for light delivery; however, such schemes are limited by the inherent low space-bandwidth product available with current digital SLMs. In this paper, we depict a fully monolithic, integrated optical platform for transparent near-to-eye holographic display requiring no supporting optics. Our solution employs a guided-wave acousto-optic spatial light modulator implemented in lithium niobate in conjunction with an integrated Bragg-regime reflection volume hologram.
Photorefractor ocular screening system
NASA Technical Reports Server (NTRS)
Richardson, John R. (Inventor); Kerr, Joseph H. (Inventor)
1987-01-01
A method and apparatus for detecting human eye defects, particularly detection of refractive error is presented. Eye reflex is recorded on color film when the eyes are exposed to a flash of light. The photographs are compared with predetermined standards to detect eye defects. The base structure of the ocular screening system is a folding interconnect structure, comprising hinged sections. Attached to one end of the structure is a head positioning station which comprises vertical support, a head positioning bracket having one end attached to the top of the support, and two head positioning lamps to verify precise head positioning. At the opposite end of the interconnect structure is a camera station with camera, electronic flash unit, and blinking fixation lamp, for photographing the eyes of persons being evaluated.
Automated analysis of angle closure from anterior chamber angle images.
Baskaran, Mani; Cheng, Jun; Perera, Shamira A; Tun, Tin A; Liu, Jiang; Aung, Tin
2014-10-21
To evaluate a novel software capable of automatically grading angle closure on EyeCam angle images in comparison with manual grading of images, with gonioscopy as the reference standard. In this hospital-based, prospective study, subjects underwent gonioscopy by a single observer, and EyeCam imaging by a different operator. The anterior chamber angle in a quadrant was classified as closed if the posterior trabecular meshwork could not be seen. An eye was classified as having angle closure if there were two or more quadrants of closure. Automated grading of the angle images was performed using customized software. Agreement between the methods was ascertained by κ statistic and comparison of area under receiver operating characteristic curves (AUC). One hundred forty subjects (140 eyes) were included, most of whom were Chinese (102/140, 72.9%) and women (72/140, 51.5%). Angle closure was detected in 61 eyes (43.6%) with gonioscopy in comparison with 59 eyes (42.1%, P = 0.73) using manual grading, and 67 eyes (47.9%, P = 0.24) with automated grading of EyeCam images. The agreement for angle closure diagnosis between gonioscopy and both manual (κ = 0.88; 95% confidence interval [CI), 0.81-0.96) and automated grading of EyeCam images was good (κ = 0.74; 95% CI, 0.63-0.85). The AUC for detecting eyes with gonioscopic angle closure was comparable for manual and automated grading (AUC 0.974 vs. 0.954, P = 0.31) of EyeCam images. Customized software for automated grading of EyeCam angle images was found to have good agreement with gonioscopy. Human observation of the EyeCam images may still be needed to avoid gross misclassification, especially in eyes with extensive angle closure. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.
Computing Optic Flow with ArduEye Vision Sensor
2013-01-01
processing algorithm that can be applied to the flight control of other robotic platforms. 15. SUBJECT TERMS Optical flow, ArduEye, vision based ...2 Figure 2. ArduEye vision chip on Stonyman breakout board connected to Arduino Mega (8) (left) and the Stonyman vision chips (7...robotic platforms. There is a significant need for small, light , less power-hungry sensors and sensory data processing algorithms in order to control the
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu, Jie; Wang, Xin, E-mail: wangx@tongji.edu.cn, E-mail: mubz@tongji.edu.cn; Zhan, Qi
This paper presents a novel lobster-eye imaging system for X-ray-backscattering inspection. The system was designed by modifying the Schmidt geometry into a treble-lens structure in order to reduce the resolution difference between the vertical and horizontal directions, as indicated by ray-tracing simulations. The lobster-eye X-ray imaging system is capable of operating over a wide range of photon energies up to 100 keV. In addition, the optics of the lobster-eye X-ray imaging system was tested to verify that they meet the requirements. X-ray-backscattering imaging experiments were performed in which T-shaped polymethyl-methacrylate objects were imaged by the lobster-eye X-ray imaging system basedmore » on both the double-lens and treble-lens Schmidt objectives. The results show similar resolution of the treble-lens Schmidt objective in both the vertical and horizontal directions. Moreover, imaging experiments were performed using a second treble-lens Schmidt objective with higher resolution. The results show that for a field of view of over 200 mm and with a 500 mm object distance, this lobster-eye X-ray imaging system based on a treble-lens Schmidt objective offers a spatial resolution of approximately 3 mm.« less
Wu, Hui-Qun; Lv, Zheng-Min; Geng, Xing-Yun; Jiang, Kui; Tang, Le-Min; Zhou, Guo-Min; Dong, Jian-Cheng
2013-01-01
To address issues in interoperability between different fundus image systems, we proposed a web eye-picture archiving and communication system (PACS) framework in conformance with digital imaging and communication in medicine (DICOM) and health level 7 (HL7) protocol to realize fundus images and reports sharing and communication through internet. Firstly, a telemedicine-based eye care work flow was established based on integrating the healthcare enterprise (IHE) Eye Care technical framework. Then, a browser/server architecture eye-PACS system was established in conformance with the web access to DICOM persistent object (WADO) protocol, which contains three tiers. In any client system installed with web browser, clinicians could log in the eye-PACS to observe fundus images and reports. Multipurpose internet mail extensions (MIME) type of a structured report is saved as pdf/html with reference link to relevant fundus image using the WADO syntax could provide enough information for clinicians. Some functions provided by open-source Oviyam could be used to query, zoom, move, measure, view DICOM fundus images. Such web eye-PACS in compliance to WADO protocol could be used to store and communicate fundus images and reports, therefore is of great significance for teleophthalmology.
NASA Astrophysics Data System (ADS)
Zhang, Chengpeng; Zhu, Yuwen; Yi, Peiyun; Peng, Linfa; Lai, Xinmin
2017-07-01
Transparent conductive electrodes (TCEs) are widely used in optoelectronic devices, such as touch screens, liquid-crystal displays and light-emitting diodes. To date, the material of the most commonly used TCEs was indium-tin oxide (ITO), which had several intrinsic drawbacks that limited its applications in the long term, including relatively high material cost and brittleness. Silver nanowire (AgNW), as one of the alternative materials for ITO TCEs, has already gained much attention all over the world. In this paper, we reported a facile method to greatly enhance the transmittance of the AgNW TCEs without reducing the electrical conductivity based on moth-eye nanostructures, and the moth-eye nanostructures were fabricated by using a roll-to-roll ultraviolet nanoimprint lithography process. Besides, the effects of mechanical pressure and bending on the moth-eye nanostructure layer were also investigated. In the research, the optical transmittance of the flexible AgNW TCEs was enhanced from 81.3% to 86.0% by attaching moth-eye nanostructures onto the other side of the flexible polyethylene terephthalate substrate while the electrical conductivity of the AgNW TCEs was not sacrificed. This research can provide a direction for the cost-effective fabrication of moth-eye nanostructures and the transmittance improvement of the flexible transparent electrodes.
Fast cat-eye effect target recognition based on saliency extraction
NASA Astrophysics Data System (ADS)
Li, Li; Ren, Jianlin; Wang, Xingbin
2015-09-01
Background complexity is a main reason that results in false detection in cat-eye target recognition. Human vision has selective attention property which can help search the salient target from complex unknown scenes quickly and precisely. In the paper, we propose a novel cat-eye effect target recognition method named Multi-channel Saliency Processing before Fusion (MSPF). This method combines traditional cat-eye target recognition with the selective characters of visual attention. Furthermore, parallel processing enables it to achieve fast recognition. Experimental results show that the proposed method performs better in accuracy, robustness and speed compared to other methods.
The research of the style of angel lobster eye x-ray optical system
NASA Astrophysics Data System (ADS)
Cheng, HuaQi; Liu, YuJiao; Zhang, ShaoWei; Hou, LinBao; Li, XingLong
2018-01-01
This paper has developed the theory research of wide field Angel lobster eye X-ray optical system based on the principle of entirely incidence. Combine the configuration characteristic of lobster eye, recommend the conclusion of beam of light focus on the half of radius whether point or parallel light. Designed the microchannel through the principle of real ray trace and got the relationship among different parameters about it using numerical value emulation. Got pixels and illumination pictures validated the wide field focus characteristic of Angel lobster eye by simulating the optical system.
Spering, Miriam; Carrasco, Marisa
2012-05-30
Feature-based attention enhances visual processing and improves perception, even for visual features that we are not aware of. Does feature-based attention also modulate motor behavior in response to visual information that does or does not reach awareness? Here we compare the effect of feature-based attention on motion perception and smooth-pursuit eye movements in response to moving dichoptic plaids--stimuli composed of two orthogonally drifting gratings, presented separately to each eye--in human observers. Monocular adaptation to one grating before the presentation of both gratings renders the adapted grating perceptually weaker than the unadapted grating and decreases the level of awareness. Feature-based attention was directed to either the adapted or the unadapted grating's motion direction or to both (neutral condition). We show that observers were better at detecting a speed change in the attended than the unattended motion direction, indicating that they had successfully attended to one grating. Speed change detection was also better when the change occurred in the unadapted than the adapted grating, indicating that the adapted grating was perceptually weaker. In neutral conditions, perception and pursuit in response to plaid motion were dissociated: While perception followed one grating's motion direction almost exclusively (component motion), the eyes tracked the average of both gratings (pattern motion). In attention conditions, perception and pursuit were shifted toward the attended component. These results suggest that attention affects perception and pursuit similarly even though only the former reflects awareness. The eyes can track an attended feature even if observers do not perceive it.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tsai, Hui-Yu; Liao, Ying-Lan; Chang Gung University / Chang Gung Memorial Hospital, Taoyun, Taiwan
Purpose: The purpose of this study is to assess eye-lens dose for patients who underwent brain CT examinations using two dose reduction Methods: organ-based tube current modulation (OBTCM) and in-plane bismuth shielding method. Methods: This study received institutional review board approval; written informed consent to participate was obtained from all patients. Ninety patients who underwent the routine brain CT examination were randomly assigned to three groups, ie. routine, OBTCM, and bismuth shield. The OBTCM technique reduced the tube current when the X-ray tube rotates in front of patients’ eye-lens region. The patients in the bismuth shield group were covered one-plymore » bismuth shield in the eyes’ region. Eye-lens doses were measured using TLD-100H chips and the total effective doses were calculated using CT-Expo according to the CT scanning parameters. The surface doses for patients at off-center positions were assessed to evaluate the off-centering effect. Results: Phantom measurements indicates that OBTCM technique could reduced by 26% to 28% of the surface dose to the eye lens, and increased by 25% of the surface dose at the opposed incident direction at the angle of 180°. Patients’ eye-lens doses were reduced 16.9% and 30.5% dose of bismuth shield scan and OBTCM scan, respectively compared to the routine scan. The eye-lens doses were apparently increased when the table position was lower than isocenter. Conclusion: Reducing the dose to the radiosensitive organs, such as eye lens, during routine brain CT examinations could lower the radiation risks. The OBTCM technique and in-plane bismuth shielding could be used to reduce the eye-lens dose. The eye-lens dose could be effectively reduced using OBTCM scan without interfering the diagnostic image quality. Patient position relative the CT gantry also affects the dose level of the eye lens. This study was supported by the grants from the Ministry of Science and Technology of Taiwan (MOST103-2314-B-182-009-MY2), and Chang Gung Memorial Hospital (CMRPD1C0682)« less
Kato, Hidenori; Ohba, Yoko; Yamazaki, Hiroyuki; Minobe, Shin-Ichiro; Sudo, Satoko; Todo, Yukiharu; Okamoto, Kazuhira; Yamashiro, Katsushige
2015-08-01
On sentinel lymph node navigation surgery for early invasive cervical cancers, to gain high sensitivity and specificity, the sentinel nodes should be detected bilaterally and pathological diagnosis should be sensitive to detect micrometastasis. To improve these problems, we tried tissue rinse liquid-based cytology and the photodynamic eye. From 2005 to 2013, 102 patients with Stage Ib1 uterine cervical cancer were subjected to sentinel lymph node navigation surgery with Technetium-99 m colloid and blue dye. For the recent 11 patients with whom bilateral sentinel node detection was not available, the photodynamic eye was selectively examined. The detected sentinel node was cut along the minor axis into 2 mm slices, soaked in 10 ml CytoRich red and then subjected to tissue rinse liquid-based cytology at the time of surgery. With the accumulation of 102 Ib1 patients subjected to sentinel lymph node navigation surgery, the bilateral sentinel node detection rate was 67.7%. The photodynamic eye was examined for the recent 11 patients who did not have bilateral signals. Out of the 11, 10 patients obtained bilateral signals successfully. During the period of examining the photodynamic eye, a total of 34 patients were subjected to sentinel lymph node navigation surgery. Thus, the overall bilateral detection rate increased to 97% in this subset. Two hundred and five lymph nodes were available as sentinel nodes. The sensitivity of tissue rinse liquid-based cytology was 91.7%, and the specificity was 100%. False positivity was 0% and false negativity was 8.3%. Detection failure was observed only with one micrometastasis and one case of isolated tumor cells. Combination of photodynamic eye detection and tissue rinse liquid-based cytology pathology can be a promising method for more rewarding sentinel node detection. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Plöchl, Michael; Ossandón, José P.; König, Peter
2012-01-01
Eye movements introduce large artifacts to electroencephalographic recordings (EEG) and thus render data analysis difficult or even impossible. Trials contaminated by eye movement and blink artifacts have to be discarded, hence in standard EEG-paradigms subjects are required to fixate on the screen. To overcome this restriction, several correction methods including regression and blind source separation have been proposed. Yet, there is no automated standard procedure established. By simultaneously recording eye movements and 64-channel-EEG during a guided eye movement paradigm, we investigate and review the properties of eye movement artifacts, including corneo-retinal dipole changes, saccadic spike potentials and eyelid artifacts, and study their interrelations during different types of eye- and eyelid movements. In concordance with earlier studies our results confirm that these artifacts arise from different independent sources and that depending on electrode site, gaze direction, and choice of reference these sources contribute differently to the measured signal. We assess the respective implications for artifact correction methods and therefore compare the performance of two prominent approaches, namely linear regression and independent component analysis (ICA). We show and discuss that due to the independence of eye artifact sources, regression-based correction methods inevitably over- or under-correct individual artifact components, while ICA is in principle suited to address such mixtures of different types of artifacts. Finally, we propose an algorithm, which uses eye tracker information to objectively identify eye-artifact related ICA-components (ICs) in an automated manner. In the data presented here, the algorithm performed very similar to human experts when those were given both, the topographies of the ICs and their respective activations in a large amount of trials. Moreover it performed more reliable and almost twice as effective than human experts when those had to base their decision on IC topographies only. Furthermore, a receiver operating characteristic (ROC) analysis demonstrated an optimal balance of false positive and false negative at an area under curve (AUC) of more than 0.99. Removing the automatically detected ICs from the data resulted in removal or substantial suppression of ocular artifacts including microsaccadic spike potentials, while the relevant neural signal remained unaffected. In conclusion the present work aims at a better understanding of individual eye movement artifacts, their interrelations and the respective implications for eye artifact correction. Additionally, the proposed ICA-procedure provides a tool for optimized detection and correction of eye movement-related artifact components. PMID:23087632
Peer Assessment of Webpage Design: Behavioral Sequential Analysis Based on Eye-Tracking Evidence
ERIC Educational Resources Information Center
Hsu, Ting-Chia; Chang, Shao-Chen; Liu, Nan-Cen
2018-01-01
This study employed an eye-tracking machine to record the process of peer assessment. Each web page was divided into several regions of interest (ROIs) based on the frame design and content. A total of 49 undergraduate students with a visual learning style participated in the experiment. This study investigated the peer assessment attitudes of the…
Is Making a Risky Choice Based on a Weighting and Adding Process? An Eye-Tracking Investigation
ERIC Educational Resources Information Center
Su, Yin; Rao, Li-Lin; Sun, Hong-Yue; Du, Xue-Lei; Li, Xingshan; Li, Shu
2013-01-01
The debate about whether making a risky choice is based on a weighting and adding process has a long history and is still unresolved. To address this long-standing controversy, we developed a comparative paradigm. Participants' eye movements in 2 risky choice tasks that required participants to choose between risky options in single-play and…
Ultra-widefield fluorescein angiography of white without pressure
Orlin, Anton; Fatoo, Aalya; Ehrlich, Joshua; D’Amico, Donald J; Chan, RV Paul; Kiss, Szilárd
2013-01-01
Purpose To describe ultra-widefield fluorescein angiography (UWFA) findings in eyes with white without pressure (WWOP) and in eyes without any obvious peripheral chorioretinal disease, and to determine if a difference exists between these two groups. Methods A retrospective review of 379 eyes undergoing diagnostic UWFA using the Optos 200Tx imaging system. Eyes were excluded if the quality of the color photograph or UWFA prevented reliable evaluation. Eyes were also excluded if there was any evidence of peripheral retinal or choroidal disease, which was thought to have an effect on UWFA (eg, peripheral background diabetic or hypertensive retinopathy, vein occlusion, or any other peripheral vascular disorder). Eyes were determined to have WWOP, based on a dilated fundus examination and color fundus photography that contained areas of peripheral retinal whitening consistent with the diagnosis. UWFA was evaluated by trained masked graders, and determined to have or not have peripheral vascular leakage and/or staining. Results Of the 379 eyes evaluated, 45 eyes were included in the study. Twelve eyes were determined to have peripheral WWOP; 33 eyes did not have WWOP on examination or color fundus photography. Three common UWFA peripheral patterns were visualized. Eyes with and without WWOP were grouped into one of three patterns. The majority of eyes without WWOP demonstrated UWFA pattern one (69.7%), while those in the WWOP group demonstrated pattern three (50%). The distribution of UWFA patterns is statistically different between those with and without WWOP (P = 0.002). In eyes without WWOP, in patients with no documented systemic microvascular disease (diabetes, hypertension), 71.4% of eyes had UWFA pattern one while 14.3% had both patterns two and three. Conclusion This study is one of the first to specifically evaluate peripheral vascular leakage/staining in eyes with WWOP as well as in eyes without any obvious peripheral chorioretinal disease. We demonstrate that a significant portion of WWOP eyes exhibit peripheral findings on UWFA (pattern one) compared to eyes without WWOP. Importantly, even in eyes that are apparently unremarkable in the periphery on exam and color photography, UWFA can still show peripheral vascular abnormalities. These results warrant further investigation. PMID:23737658
A relationship between eye movement patterns and performance in a precognitive tracking task
NASA Technical Reports Server (NTRS)
Repperger, D. W.; Hartzell, E. J.
1977-01-01
Eye movements made by various subjects in the performance of a precognitive tracking task are studied. The tracking task persented by an antiaircraft artillery (AAA) simulator has an input forcing function represented by a deterministic aircraft fly-by. The performance of subjects is ranked by two metrics. Good, mediocre, and poor trackers are selected for analysis based on performance during the difficult segment of the tracking task and over replications. Using phase planes to characterize both the eye movement patterns and the displayed error signal, a simple metric is developed to study these patterns. Two characterizations of eye movement strategies are defined and quantified. Using these two types of eye strategies, two conclusions are obtained about good, mediocre, and poor trackers. First, the eye tracker who used a fixed strategy will consistently perform better. Secondly, the best fixed strategy is defined as a Crosshair Fixator.
Expert System Diagnosis of Cataract Eyes Using Fuzzy Mamdani Method
NASA Astrophysics Data System (ADS)
Santosa, I.; Romla, L.; Herawati, S.
2018-01-01
Cataracts are eye diseases characterized by cloudy or opacity of the lens of the eye by changing the colour of black into grey-white which slowly continues to grow and develop without feeling pain and pain that can cause blindness in human vision. Therefore, researchers make an expert system of cataract eye disease diagnosis by using Fuzzy Mamdani and how to care. The fuzzy method can convert the crisp value to linguistic value by fuzzification and includes in the rule. So this system produces an application program that can help the public in knowing cataract eye disease and how to care based on the symptoms suffered. From the results of the design implementation and testing of expert system applications to diagnose eye disease cataracts, it can be concluded that from a trial of 50 cases of data, obtained test results accuracy between system predictions with expert predictions obtained a value of 78% truth.
The Barrie Jones Lecture—Eye care for the neglected population: challenges and solutions
Rao, G N
2015-01-01
Globally, pockets of ‘neglected populations' do not have access to basic health-care services and carry a much greater risk of blindness and visual impairment. While large-scale public health approaches to control blindness due to vitamin A deficiency, onchocerciasis, and trachoma are successful, other causes of blindness still take a heavy toll in the population. High-quality comprehensive eye care that is equitable is the approach that needs wide-scale application to alleviate this inequity. L V Prasad Eye Institute of India developed a multi-tier pyramidal model of eye care delivery that encompasses all levels from primary to advanced tertiary (quaternary). This has demonstrated the feasibility of ‘Universal Eye Health Coverage' covering promotive, preventive, corrective, and rehabilitative aspects of eye care. Using human resources with competency-based training, effective and cost-effective care could be provided to many disadvantaged people. PMID:25567375
Real-Time Detection and Measurement of Eye Features from Color Images
Borza, Diana; Darabant, Adrian Sergiu; Danescu, Radu
2016-01-01
The accurate extraction and measurement of eye features is crucial to a variety of domains, including human-computer interaction, biometry, and medical research. This paper presents a fast and accurate method for extracting multiple features around the eyes: the center of the pupil, the iris radius, and the external shape of the eye. These features are extracted using a multistage algorithm. On the first stage the pupil center is localized using a fast circular symmetry detector and the iris radius is computed using radial gradient projections, and on the second stage the external shape of the eye (of the eyelids) is determined through a Monte Carlo sampling framework based on both color and shape information. Extensive experiments performed on a different dataset demonstrate the effectiveness of our approach. In addition, this work provides eye annotation data for a publicly-available database. PMID:27438838
Lee, Jin; Yoo, Ha-Na; Lee, Byoung-Hee
2017-09-01
[Purpose] To determine the effect of augmented reality (AR)-based otago exercise on muscle strength, balance, and physical factors in falls of elderly women. [Subjects and Methods] Thirty subjects were randomly assigned to AR group (AR, n=10), yoga group (yoga, n=10), and self-exercise group (self, n=10). For 12 weeks, these groups were given lessons related to AR-based otago exercise including strengthening, balance training, or yoga three times a week (60 minutes each time) and self-exercise using elastic band exercise program. [Results] Knee flexion and ankle dorsiflexion strength were significantly improved in all three groups (AR, yoga, and self-exercise groups). Regarding balance, eye open center of pressure-x (EO CoP-x) was significantly decreased in AR group and yoga group. However, eye close CoP-x, eye open standard deviation-x (EO SD-x), and eye open height of ellipse (EO HoE) were only significantly decreased in AR group. AR group also showed meaningfully improved results in morse fall scale. [Conclusion] Augmented reality-based otago exercise can improve muscle strength, balance, and physical factors in elderly women to prevent falls.
NASA Astrophysics Data System (ADS)
Ortiz, D.; Anera, R. G.; Saiz, J. M.; Jiménez, J. R.; Moreno, F.; Jiménez Del Barco, L.; González, F.
2006-11-01
This study focuses on the changes induced in both the asphericity and homogeneity of the cornea for a group of myopic eyes undergoing LASIK surgery. Eyes were characterized by a Kooijman-based customized eye model in which changes were introduced in the form of Gaussian-distributed refractive-index variations of given correlation length for the inhomogeneities and in the form of an expression, based on the modified Munnerlyn's paraxial formula, for the post-LASIK asphericity. Visual quality was evaluated in terms of the Modulation Transfer Function and the Point-Spread Function. The results show that, on average, the evolution of visual acuity is consistent with the change in corneal asphericity, while the evolution of contrast sensitivity requires a loss in corneal homogeneity in order to be explained. By including both effects in the model, the overall model performance in predicting visual quality is improved.
New vehicle based on a microemulsion for topical ocular administration of dexamethasone.
Fialho, Sílvia Ligório; da Silva-Cunha, Armando
2004-12-01
Eye drops are the most used dosage form by the ocular route, in spite of their low bioavailability. Due to their properties and numerous advantages, microemulsions are promising systems for topical ocular drug delivery. They can increase water solubility of the drug and enhance drug absorption into the eye. The present study describes the development and characterization of an oil-in-water microemulsion containing dexamethasone and the evaluation of its pharmacokinetics in rabbits after topical ocular application. The microemulsion was prepared by the titration technique. Its physico-chemical characteristics and stability were determined. The ocular irritation test and the pharmacokinetics of this system were studied in white rabbits. The developed system showed an acceptable physico-chemical behaviour and presented good stability for 3 months. The ocular irritation test used suggested that the microemulsion did not provide significant alteration to eyelids, conjunctiva, cornea and iris. This formulation showed greater penetration of dexamethasone in the anterior segment of the eye and also release of the drug for a longer time when compared with a conventional preparation. The area under the curve obtained for the microemulsion system was more than twofold higher than that of the conventional preparation (P < 0.05). The microemulsion-based dexamethasone eye drop is advantageous for ophthalmic use because it is well-tolerated in the eye and seemed to provide a higher degree of bioavailability. The developed system shows greater penetration in the eye, allowing the possibility of decreasing the number of applications of eye drops per day.
Detection of cat-eye effect echo based on unit APD
NASA Astrophysics Data System (ADS)
Wu, Dong-Sheng; Zhang, Peng; Hu, Wen-Gang; Ying, Jia-Ju; Liu, Jie
2016-10-01
The cat-eye effect echo of optical system can be detected based on CCD, but the detection range is limited within several kilometers. In order to achieve long-range even ultra-long-range detection, it ought to select APD as detector because of the high sensitivity of APD. The detection system of cat-eye effect echo based on unit APD is designed in paper. The implementation scheme and key technology of the detection system is presented. The detection performances of the detection system including detection range, detection probability and false alarm probability are modeled. Based on the model, the performances of the detection system are analyzed using typical parameters. The results of numerical calculation show that the echo signal-to-noise ratio is greater than six, the detection probability is greater than 99.9% and the false alarm probability is less tan 0.1% within 20 km detection range. In order to verify the detection effect, we built the experimental platform of detection system according to the design scheme and carry out the field experiments. The experimental results agree well with the results of numerical calculation, which prove that the detection system based on the unit APD is feasible to realize remote detection for cat-eye effect echo.
Newbold, Georgina M; Outerbridge, Catherine A; Kass, Philip H; Maggs, David J
2014-06-01
To determine how frequently Malassezia spp were identified on the periocular skin of dogs and assess the respective associations between the presence of Malassezia spp on the periocular skin and blepharitis, ocular discharge, and the application of ophthalmic medications. Prospective clinical study. 167 eyelids of 84 dogs. Samples obtained from the surface of the eyelid skin by use of adhesive tape were evaluated cytologically for the presence of Malassezia spp. Dogs were grouped on the basis of the presence of blepharitis, nature of ocular discharge, and whether ophthalmic medications were applied, and the proportion of samples with Malassezia spp was compared among the groups. Malassezia spp were detected in 19 samples, of which 15 were obtained from eyes without blepharitis and 14 were obtained from eyes treated with topical ophthalmic medications. The proportion of samples with Malassezia spp was significantly higher for eyes with ocular discharge than for eyes without ocular discharge, especially if that discharge was mucoid or mucopurulent, and for eyes that were treated with aqueous-based medications only or a combination of oil- and aqueous-based medications than for eyes that were not treated. Malassezia organisms were detected on the periocular skin of 3 of 56 (5%) clinically normal dogs. Malassezia organisms were also frequently found on the periocular skin of dogs that had mucoid or mucopurulent ocular discharge or that were administered topical aqueous-based ophthalmic medications, and the periocular skin of these dogs should be cytologically evaluated for Malassezia organisms.
Nyström, Marcus; Andersson, Richard; Magnusson, Måns; Pansell, Tony; Hooge, Ignace
2015-02-01
It is well known that the crystalline lens (henceforth lens) can oscillate (or 'wobble') relative to the eyeball at the end of saccades. Recent research has proposed that such wobbling of the lens is a source of post-saccadic oscillations (PSOs) seen in data recorded by eye trackers that estimate gaze direction from the location of the pupil. Since the size of the lens wobbles increases with accommodative effort, one would predict a similar increase of PSO-amplitude in data recorded with a pupil based eye tracker. In four experiments, we investigated the role of lens accommodation on PSOs in a video-based eye tracker. In Experiment 1, we replicated previous results showing that PSO-amplitudes increase at near viewing distances (large vergence angles), when the lens is highly accommodated. In Experiment 2a, we manipulated the accommodative state of the lens pharmacologically using eye drops at a fixed viewing distance and found, in contrast to Experiment 1, no significant difference in PSO-amplitude related to the accommodative state of the lens. Finally, in Experiment 2b, the effect of vergence angle was investigated by comparing PSO-amplitudes at near and far while maintaining a fixed lens accommodation. Despite the pharmacologically fixed degree of accommodation, PSO-amplitudes were systematically larger in the near condition. In summary, PSOs cannot exhaustively be explained by lens wobbles. Possible confounds related to pupil size and eye-camera angle are investigated in Experiments 3 and 4, and alternative mechanisms behind PSOs are probed in the discussion. Copyright © 2014 Elsevier Ltd. All rights reserved.
Driver fatigue alarm based on eye detection and gaze estimation
NASA Astrophysics Data System (ADS)
Sun, Xinghua; Xu, Lu; Yang, Jingyu
2007-11-01
The driver assistant system has attracted much attention as an essential component of intelligent transportation systems. One task of driver assistant system is to prevent the drivers from fatigue. For the fatigue detection it is natural that the information about eyes should be utilized. The driver fatigue can be divided into two types, one is the sleep with eyes close and another is the sleep with eyes open. Considering that the fatigue detection is related with the prior knowledge and probabilistic statistics, the dynamic Bayesian network is used as the analysis tool to perform the reasoning of fatigue. Two kinds of experiments are performed to verify the system effectiveness, one is based on the video got from the laboratory and another is based on the video got from the real driving situation. Ten persons participate in the test and the experimental result is that, in the laboratory all the fatigue events can be detected, and in the practical vehicle the detection ratio is about 85%. Experiments show that in most of situations the proposed system works and the corresponding performance is satisfying.
Maa, April Y; Wojciechowski, Barbara; Hunt, Kelly; Dismuke, Clara; Janjua, Rabeea; Lynch, Mary G
2017-01-01
Veterans are at high risk for eye disease because of age and comorbid conditions. Access to eye care is challenging within the entire Veterans Hospital Administration's network of hospitals and clinics in the USA because it is the third busiest outpatient clinical service and growing at a rate of 9% per year. Rural and highly rural veterans face many more barriers to accessing eye care because of distance, cost to travel, and difficulty finding care in the community as many live in medically underserved areas. Also, rural veterans may be diagnosed in later stages of eye disease than their non-rural counterparts due to lack of access to specialty care. In March 2015, Technology-based Eye Care Services (TECS) was launched from the Atlanta Veterans Affairs (VA) as a quality improvement project to provide eye screening services for rural veterans. By tracking multiple measures including demographic and access to care metrics, data shows that TECS significantly improved access to care, with 33% of veterans receiving same-day access and >98% of veterans receiving an appointment within 30 days of request. TECS also provided care to a significant percentage of homeless veterans, 10.6% of the patients screened. Finally, TECS reduced healthcare costs, saving the VA up to US$148 per visit and approximately US$52 per patient in round trip travel reimbursements when compared to completing a face-to-face exam at the medical center. Overall savings to the VA system in this early phase of TECS totaled US$288,400, about US$41,200 per month. Other healthcare facilities may be able to use a similar protocol to extend care to at-risk patients.
NASA Astrophysics Data System (ADS)
Yasuoka, Fatima M. M.; Matos, Luciana; Cremasco, Antonio; Numajiri, Mirian; Marcato, Rafael; Oliveira, Otavio G.; Sabino, Luis G.; Castro N., Jarbas C.; Bagnato, Vanderlei S.; Carvalho, Luis A. V.
2016-03-01
An optical system that conjugates the patient's pupil to the plane of a Hartmann-Shack (HS) wavefront sensor has been simulated using optical design software. And an optical bench prototype is mounted using mechanical eye device, beam splitter, illumination system, lenses, mirrors, mirrored prism, movable mirror, wavefront sensor and camera CCD. The mechanical eye device is used to simulate aberrations of the eye. From this device the rays are emitted and travelled by the beam splitter to the optical system. Some rays fall on the camera CCD and others pass in the optical system and finally reach the sensor. The eye models based on typical in vivo eye aberrations is constructed using the optical design software Zemax. The computer-aided outcomes of each HS images for each case are acquired, and these images are processed using customized techniques. The simulated and real images for low order aberrations are compared using centroid coordinates to assure that the optical system is constructed precisely in order to match the simulated system. Afterwards a simulated version of retinal images is constructed to show how these typical eyes would perceive an optotype positioned 20 ft away. Certain personalized corrections are allowed by eye doctors based on different Zernike polynomial values and the optical images are rendered to the new parameters. Optical images of how that eye would see with or without corrections of certain aberrations are generated in order to allow which aberrations can be corrected and in which degree. The patient can then "personalize" the correction to their own satisfaction. This new approach to wavefront sensing is a promising change in paradigm towards the betterment of the patient-physician relationship.
Role of percent tissue altered on ectasia after LASIK in eyes with suspicious topography.
Santhiago, Marcony R; Smadja, David; Wilson, Steven E; Krueger, Ronald R; Monteiro, Mario L R; Randleman, J Bradley
2015-04-01
To investigate the association of the percent tissue altered (PTA) with the occurrence of ectasia after LASIK in eyes with suspicious preoperative corneal topography. This retrospective comparative case-control study compared associations of reported ectasia risk factors in 129 eyes, including 57 eyes with suspicious preoperative Placido-based corneal topography that developed ectasia after LASIK (suspect ectasia group), 32 eyes with suspicious topography that remained stable for at least 3 years after LASIK (suspect control group), and 30 eyes that developed ectasia with bilateral normal topography (normal topography ectasia group). Groups were subdivided based on topographic asymmetry into high- or low-suspect groups. The PTA, preoperative central corneal thickness (CCT), residual stromal bed (RSB), and age (years) were evaluated in univariate and multivariate analyses. Average PTA values for normal topography ectasia (45), low-suspect ectasia (39), high-suspect ectasia (36), low-suspect control (32), and high-suspect control (29) were significantly different from one another in all comparisons (P < .003) except high- and low-suspect ectasia groups (P = .033), and presented the highest discriminative capability of all variables evaluated. Age was only significantly different between the high-suspect ectasia and normal topography ectasia groups, and CCT was not significantly different between any groups. Stepwise logistic regression revealed the PTA as the most significant independent variable (P < .0001), with RSB the next most significant parameter. There remains a significant correlation between PTA values and ectasia risk after LASIK, even in eyes with suspicious corneal topography. Less tissue alteration, or a lower PTA value, was necessary to induce ectasia in eyes with more remarkable signs of topographic abnormality, and PTA provided better discriminative capabilities than RSB for all study populations. Copyright 2015, SLACK Incorporated.
Improved eye- and skin-color prediction based on 8 SNPs.
Hart, Katie L; Kimura, Shey L; Mushailov, Vladimir; Budimlija, Zoran M; Prinz, Mechthild; Wurmbach, Elisa
2013-06-01
To improve the 7-plex system to predict eye and skin color by increasing precision and detailed phenotypic descriptions. Analysis of an eighth single nucleotide polymorphism (SNP), rs12896399 (SLC24A4), showed a statistically significant association with human eye color (P=0.007) but a rather poor strength of agreement (κ=0.063). This SNP was added to the 7-plex system (rs12913832 at HERC2, rs1545397 at OCA2, rs16891982 at SLC45A2, rs1426654 at SLC24A5, rs885479 at MC1R, rs6119471 at ASIP, and rs12203592 at IRF4). Further, the instruction guidelines on the interpretation of genotypes were changed to create a new 8-plex system. This was based on the analysis of an 803-sample training set of various populations. The newly developed 8-plex system can predict the eye colors brown, green, and blue, and skin colors light, not dark, and not light. It is superior to the 7-plex system with its additional ability to predict blue eye and light skin color. The 8-plex system was tested on an additional 212 samples, the test set. Analysis showed that the number of positive descriptions for eye colors as being brown, green, or blue increased significantly (P=6.98e-15, z-score: -7.786). The error rate for eye-color prediction was low, at approximately 5%, while the skin color prediction showed no error in the test set (1% in training set). We can conclude that the new 8-plex system for the prediction of eye and skin color substantially enhances its former version.
Ocular trauma in a rural population of southern India: the Andhra Pradesh Eye Disease Study.
Krishnaiah, Sannapaneni; Nirmalan, Praveen K; Shamanna, Bindiganavale R; Srinivas, Marmamula; Rao, Gullapalli N; Thomas, Ravi
2006-07-01
To determine the prevalence of ocular trauma and proportion of blindness and visual impairment due to ocular trauma in a rural population of southern India. Population-based cross-sectional epidemiological study. A total of 7771 subjects of all ages, representative of the rural population of Andhra Pradesh. The subjects underwent a detailed interview and comprehensive ocular evaluation as part of the population-based Andhra Pradesh Eye Disease Study. An eye was considered to be blind due to trauma if best-corrected distance visual acuity was worse than 6/60 and the cause was attributed to ocular trauma. A total of 824 (10.6%) subjects gave a history of ocular trauma in either eye, including 76 (1.0%) persons reporting trauma in both eyes. The overall age- and gender-adjusted prevalence of history of eye injury in this rural population was 7.5% (95% confidence interval [CI], 7.0%-8.1%). Men were more likely to have an eye injury than women (odds ratio [OR], 2.1 [95% CI, 1.8-2.5]). After adjusting for gender and other demographic factors, ocular trauma was significantly more frequent among laborers (OR, 1.5 [95% CI, 1.2-1.7]) when compared with other occupational groups. After adjusting for gender, injury with vegetable matter such as a thorn, branch of a tree, plant secretion, etc. (n = 373 [45.3%]) was the major cause of trauma reported in this population. The majority of the eye injuries occurred at the workplace (n = 461 [55.9%]), followed by home (n = 179 [21.7%]). The majority of those affected (n = 806 [97.8%]) did not wear any eye protection at the time of trauma. A significant proportion (n = 307 [43.1%]) of subjects who sought treatment for an eye injury went to an ophthalmologist. Trauma was responsible for unilateral blindness in 39 subjects, an age- and gender-adjusted prevalence of 0.6% (95% CI, 0.4%-0.8%). Most ocular injuries in this rural population occurred at the workplace, suggesting the need to explore workplace strategies to minimize ocular trauma as a priority. Eye care programs targeting high-risk ocular trauma groups may need to consider ocular trauma as a priority in eye health awareness strategies to reduce blindness due to trauma.
Gupta, Mrinali Patel; Chan, RV. Paul; Anzures, Rachelle; Ostmo, Susan; Jonas, Karyn; Chiang, Michael F.
2015-01-01
Purpose To characterize the frequency of and clinical indications for which experts treat retinopathy of prematurity (ROP) milder than Type 1 disease, the recommended threshold for treatment from established consensus guidelines. Design Descriptive analysis Methods Setting: Multicenter. Study Population: A database of 1444 eyes generated prospectively from all babies screened for ROP at one of 6 major ROP centers whose parents provided informed consent. Intervention: Retrospective review of the database and charts to identify all patients treated for ROP milder than Type 1. Main Outcome Measure: Indication(s) for treatment. Results 137 eyes of 70 infants were treated for ROP. Of these 137 eyes, 13 (9.5%) were treated despite a clinical diagnosis milder than Type 1 ROP. Indications for treatment included: active ROP with the fellow eye being treated for Type 1 ROP (2 eyes, 15.4%); concerning structural changes (9 eyes, 69.2%), including tangential traction with temporal vessel straightening concerning for macular dragging (8 eyes, 61.5%) and thick stage 3 membranes with anteroposterior traction concerning for progression to stage 4 ROP (3 eyes, 23.1%); persistent ROP at an advanced postmenstrual age (4 eyes, 30.8%); and/or vitreous hemorrhage (3 eyes, 23.1%). Conclusion Experts in this study occasionally recommended treatment in eyes with disease less than Type 1 ROP. This study has important clinical implications and highlights the role of individual clinical judgment in situations not covered by evidence-based treatment guidelines. PMID:26705094
Characteristics of ocular pain complaints in patients with idiopathic dry eye symptoms
Kalangara, Jerry P.; Galor, Anat; Levitt, Roy C.; Covington, Derek B.; McManus, Katherine T.; Sarantopoulos, Constantine D.; Felix, Elizabeth R.
2016-01-01
Objective The purpose of this study was to examine the severity and quality of ocular pain complaints in patients with dry eye symptoms. Methods Subjects with clinically-relevant dry eye symptoms (dryness, discomfort, tearing) of unknown origin seen in the Miami Veterans Affairs eye clinic were administered questionnaires for dry eye symptoms and ocular pain and underwent a standardized ocular examination. Qualities and severity ratings of ocular pain in subjects with idiopathic dry eye were compared to similar measures from published data in other chronic pain populations. Results The study sample consisted of 154 subjects, of which 91% were male and ranged in age from 27 to 89 (mean age = 61). Fifty-three percent of participants reported an average ocular pain of at least moderate intensity (numerical rating scale (NRS) ≥ 4), with specific characteristics (i.e., “burning” spontaneous pain) reported at frequencies comparable to prevalent chronic neuropathic pain syndromes as reported in the literature. Significant correlations were found between ocular pain metrics and dry eye symptom severity scores (r=0.57 to 0.66). Dry eye signs, however, did not generally correlate with ocular pain severity. Conclusions A significant proportion of subjects with idiopathic dry eye symptoms reported moderate or greater ocular pain intensity, with the majority endorsing descriptors commonly used by patients with non-ocular neuropathic pain conditions. Identifying sub-groups of dry eye patients based on the presence and characteristics of ocular pain complaints may improve dry eye sub classification and better individualize treatment strategies. PMID:26925537
Characteristics of Ocular Pain Complaints in Patients With Idiopathic Dry Eye Symptoms.
Kalangara, Jerry P; Galor, Anat; Levitt, Roy C; Covington, Derek B; McManus, Katherine T; Sarantopoulos, Constantine D; Felix, Elizabeth R
2017-05-01
The purpose of this study was to examine the severity and quality of ocular pain complaints in patients with dry eye symptoms. Subjects with clinically relevant dry eye symptoms (dryness, discomfort, tearing) of unknown origin seen in the Miami Veterans Affairs eye clinic were administered questionnaires for dry eye symptoms and ocular pain and underwent a standardized ocular examination. Qualities and severity ratings of ocular pain in subjects with idiopathic dry eye were compared with similar measures from published data in other chronic pain populations. The study sample consisted of 154 subjects, of which 91% were men and ranged in age from 27 to 89 (mean age=61). Fifty-three percent of participants reported an average ocular pain of at least moderate intensity (numerical rating scale≥4), with specific characteristics (i.e., "burning" spontaneous pain) reported at frequencies comparable to prevalent chronic neuropathic pain syndromes as reported in the literature. Significant correlations were found between ocular pain metrics and dry eye symptom severity scores (r=0.57-0.66). Dry eye signs, however, did not generally correlate with ocular pain severity. A significant proportion of subjects with idiopathic dry eye symptoms reported moderate or greater ocular pain intensity, with most endorsing descriptors commonly used by patients with nonocular neuropathic pain conditions. Identifying subgroups of dry eye patients based on the presence and characteristics of ocular pain complaints may improve dry eye subclassification and better individualize treatment strategies.
MAPK Target Sites of Eyes Absent Are Not Required for Eye Development or Survival in Drosophila
Jusiak, Barbara; Abulimiti, Abuduaini; Haelterman, Nele; Chen, Rui; Mardon, Graeme
2012-01-01
Eyes absent (Eya) is a highly conserved transcription cofactor and protein phosphatase that plays an essential role in eye development and survival in Drosophila. Ectopic eye induction assays using cDNA transgenes have suggested that mitogen activated protein kinase (MAPK) activates Eya by phosphorylating it on two consensus target sites, S402 and S407, and that this activation potentiates the ability of Eya to drive eye formation. However, this mechanism has never been tested in normal eye development. In the current study, we generated a series of genomic rescue transgenes to investigate how loss- and gain-of-function mutations at these two MAPK target sites within Eya affect Drosophila survival and normal eye formation: eya+GR, the wild-type control; eyaSAGR, which lacks phosphorylation at the two target residues; and eyaSDEGR, which contains phosphomimetic amino acids at the same two residues. Contrary to the previous studies in ectopic eye development, all eya genomic transgenes tested rescue both eye formation and survival equally effectively. We conclude that, in contrast to ectopic eye formation, MAPK-mediated phosphorylation of Eya on S402 and S407 does not play a role in normal development. This is the first study in Drosophila to evaluate the difference in outcomes between genomic rescue and ectopic cDNA-based overexpression of the same gene. These findings indicate similar genomic rescue strategies may prove useful for re-evaluating other long-standing Drosophila developmental models. PMID:23251383
Idiosyncratic characteristics of saccadic eye movements when viewing different visual environments.
Andrews, T J; Coppola, D M
1999-08-01
Eye position was recorded in different viewing conditions to assess whether the temporal and spatial characteristics of saccadic eye movements in different individuals are idiosyncratic. Our aim was to determine the degree to which oculomotor control is based on endogenous factors. A total of 15 naive subjects viewed five visual environments: (1) The absence of visual stimulation (i.e. a dark room); (2) a repetitive visual environment (i.e. simple textured patterns); (3) a complex natural scene; (4) a visual search task; and (5) reading text. Although differences in visual environment had significant effects on eye movements, idiosyncrasies were also apparent. For example, the mean fixation duration and size of an individual's saccadic eye movements when passively viewing a complex natural scene covaried significantly with those same parameters in the absence of visual stimulation and in a repetitive visual environment. In contrast, an individual's spatio-temporal characteristics of eye movements during active tasks such as reading text or visual search covaried together, but did not correlate with the pattern of eye movements detected when viewing a natural scene, simple patterns or in the dark. These idiosyncratic patterns of eye movements in normal viewing reveal an endogenous influence on oculomotor control. The independent covariance of eye movements during different visual tasks shows that saccadic eye movements during active tasks like reading or visual search differ from those engaged during the passive inspection of visual scenes.
Biometric recognition via texture features of eye movement trajectories in a visual searching task.
Li, Chunyong; Xue, Jiguo; Quan, Cheng; Yue, Jingwei; Zhang, Chenggang
2018-01-01
Biometric recognition technology based on eye-movement dynamics has been in development for more than ten years. Different visual tasks, feature extraction and feature recognition methods are proposed to improve the performance of eye movement biometric system. However, the correct identification and verification rates, especially in long-term experiments, as well as the effects of visual tasks and eye trackers' temporal and spatial resolution are still the foremost considerations in eye movement biometrics. With a focus on these issues, we proposed a new visual searching task for eye movement data collection and a new class of eye movement features for biometric recognition. In order to demonstrate the improvement of this visual searching task being used in eye movement biometrics, three other eye movement feature extraction methods were also tested on our eye movement datasets. Compared with the original results, all three methods yielded better results as expected. In addition, the biometric performance of these four feature extraction methods was also compared using the equal error rate (EER) and Rank-1 identification rate (Rank-1 IR), and the texture features introduced in this paper were ultimately shown to offer some advantages with regard to long-term stability and robustness over time and spatial precision. Finally, the results of different combinations of these methods with a score-level fusion method indicated that multi-biometric methods perform better in most cases.
Biometric recognition via texture features of eye movement trajectories in a visual searching task
Li, Chunyong; Xue, Jiguo; Quan, Cheng; Yue, Jingwei
2018-01-01
Biometric recognition technology based on eye-movement dynamics has been in development for more than ten years. Different visual tasks, feature extraction and feature recognition methods are proposed to improve the performance of eye movement biometric system. However, the correct identification and verification rates, especially in long-term experiments, as well as the effects of visual tasks and eye trackers’ temporal and spatial resolution are still the foremost considerations in eye movement biometrics. With a focus on these issues, we proposed a new visual searching task for eye movement data collection and a new class of eye movement features for biometric recognition. In order to demonstrate the improvement of this visual searching task being used in eye movement biometrics, three other eye movement feature extraction methods were also tested on our eye movement datasets. Compared with the original results, all three methods yielded better results as expected. In addition, the biometric performance of these four feature extraction methods was also compared using the equal error rate (EER) and Rank-1 identification rate (Rank-1 IR), and the texture features introduced in this paper were ultimately shown to offer some advantages with regard to long-term stability and robustness over time and spatial precision. Finally, the results of different combinations of these methods with a score-level fusion method indicated that multi-biometric methods perform better in most cases. PMID:29617383
Computer Analysis of Eye Blood-Vessel Images
NASA Technical Reports Server (NTRS)
Wall, R. J.; White, B. S.
1984-01-01
Technique rapidly diagnoses diabetes mellitus. Photographs of "whites" of patients' eyes scanned by computerized image analyzer programmed to quantify density of small blood vessels in conjuctiva. Comparison with data base of known normal and diabetic patients facilitates rapid diagnosis.
Selected area growth integrated wavelength converter based on PD-EAM optical logic gate
NASA Astrophysics Data System (ADS)
Bin, Niu; Jifang, Qiu; Daibing, Zhou; Can, Zhang; Song, Liang; Dan, Lu; Lingjuan, Zhao; Jian, Wu; Wei, Wang
2014-09-01
A selected area growth wavelength converter based on a PD-EAM optical logic gate for WDM application is presented, integrating an EML transmitter and a SOA-PD receiver. The design, fabrication, and DC characters were analyzed. A 2 Gb/s NRZ signal based on the C-band wavelength converted to 1555 nm with the highest extinction ratio of 7 dB was achieved and wavelength converted eye diagrams with eyes opened were presented.
Kim, Jonghyeon; Dally, Leonard G; Ederer, Fred; Gaasterland, Douglas E; VanVeldhuisen, Paul C; Blackwell, Beth; Sullivan, E Kenneth; Prum, Bruce; Shafranov, George; Beck, Allen; Spaeth, George L
2004-11-01
To determine the least worsening of a visual field (VF) and the least number of confirming tests needed to identify progression of glaucomatous VF defects. Cohort study of participants in a clinical trial. Seven hundred fifty-two eyes of 565 patients with advanced glaucoma. Visual field tests were quantified with the Advanced Glaucoma Intervention Study (AGIS) VF defect score and the Humphrey Field Analyzer mean deviation (MD). Follow-up was 8 to 13 years. Two measures based on the AGIS VF defect score: (1) sustained decrease of VF (SDVF), a worsening from baseline by 2 (alternatively, 3 or 4) or more units and sustained for 2 (alternatively, 3) consecutive 6-month visits and (2) after the occurrence of SDVF, the average percent of eyes with worsening by 2 (alternatively, 3 or 4) or more units from baseline. Two similar measures based on MD. Based on the original AGIS criteria for SDVF (a worsening of 4 units in the AGIS score sustained during 3 consecutive 6-month visits), 31% of eyes had an SDVF. The percent of eyes with a sustained event increases by approximately 10% when either the minimum number of units of field loss or the minimum number of 6-month visits during which the loss is sustained decreases by 1. During 3 years of follow-up after a sustained event, a worsening of at least 2 units was found in 72% of eyes that had a 2-visit sustained event. The same worsening was found in 84% of eyes that had a 3-visit sustained event. Through the next 10 years after a sustained event, based on worsening of 2, 3, or 4 units at 2 or 3 consecutive tests, the loss reoccurred, on average, in >/=75% of study eyes. Results for MD are similar. In patients with advanced glaucoma, a single confirmatory test 6 months after a VF worsening indicates with at least 72% probability a persistent defect when the worsening is defined by at least 2 units of AGIS score or by at least 2 decibels of MD. When the number of confirmatory tests is increased from 1 to 2, the percentage of eyes that show a persistent defect increases from 72% to 84%.
Effect of marking pens on femtosecond laser-assisted flap creation.
Ide, Takeshi; Kymionis, George D; Abbey, Ashkan M; Yoo, Sonia H; Culbertson, William W; O'Brien, Terrence P
2009-06-01
To compare the ease of the flap lift after central corneal marking with 2 types of marking pens after femtosecond laser-assisted flap creation in laser in situ keratomileusis. Bascom Palmer Eye Institute, University of Miami, Miami, Florida, USA. Porcine eyes were prepared for flap creation with a femtosecond laser (IntraLase). The eyes were assigned to 1 of 4 groups. After the femtosecond laser treatment, the difficulty of flap lifting the 4 groups was compared. Twelve porcine eyes, 3 in each group, were evaluated. In the 2 groups in which an oil-based pen was used, the corneal flap could not be lifted. In the 2 groups in which a water-based pen was used, the corneal flap was easily lifted. Oil-based ink may reduce the ability of the femtosecond laser to penetrate the cornea. The resultant corneal flap may require aggressive manipulation to be lifted. When used to mark the center of the cornea before flap creation, water-based ink provided greater ease of corneal flap lifting than oil-based ink. Because the marking is located over the center of the pupil, any alteration of the cornea in this area from aggressive flap lifting may result in substantial visual loss. Therefore, the use of an oil-based ink to mark the central cornea must be avoided to prevent traumatic irregularities of the flap stroma.
Is Eye Color Related to Dental Injection Pain? A Prospective, Randomized, Single-blind Study.
Hyde, Jason; Fowler, Sara; Drum, Melissa; Reader, Al; Nusstein, John; Beck, Mike
2018-05-01
Recent studies have investigated the relationship between pain perception and specific phenotypes such as red hair color and various eye colors. Further investigations into biomarkers as they relate to pain could be useful in understanding underlying genetic components involved in these pathways. Additionally, it would be clinically useful to determine if a patient would be more likely to experience pain during dental treatment based on eye color. The purpose of this study was to investigate a link between eye color and perceived injection pain in healthy, asymptomatic white women. Three hundred healthy, adult, white female patients were included, 133 with dark eyes and 167 with light eyes. Dental anxiety was assessed with the Corah Dental Anxiety Scale. Subjects with their eye color masked by dark glasses received a right maxillary lateral incisor infiltration of 1 cartridge of 2% lidocaine with 1:100,000 epinephrine. Patients rated their injection pain on a 170-mm Heft-Parker visual analog scale. Photographs of the subjects' eyes were taken after the infiltrations and categorized into dark- and light-eyed groups by 3 independent observers. Comparisons for injection pain were analyzed using analysis of variance and the Tukey-Kramer test. No significant differences were found for pain of injection between dark- or light-eyed subjects. Eye color was not shown to be a predictor for injection pain in white women. Therefore, eye color would not be clinically useful in determining if a patient would be more likely to experience pain during dental treatment. Copyright © 2018 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Popelka, Stanislav; Stachoň, Zdeněk; Šašinka, Čeněk; Doležalová, Jitka
2016-01-01
The mixed research design is a progressive methodological discourse that combines the advantages of quantitative and qualitative methods. Its possibilities of application are, however, dependent on the efficiency with which the particular research techniques are used and combined. The aim of the paper is to introduce the possible combination of Hypothesis with EyeTribe tracker. The Hypothesis is intended for quantitative data acquisition and the EyeTribe is intended for qualitative (eye-tracking) data recording. In the first part of the paper, Hypothesis software is described. The Hypothesis platform provides an environment for web-based computerized experiment design and mass data collection. Then, evaluation of the accuracy of data recorded by EyeTribe tracker was performed with the use of concurrent recording together with the SMI RED 250 eye-tracker. Both qualitative and quantitative results showed that data accuracy is sufficient for cartographic research. In the third part of the paper, a system for connecting EyeTribe tracker and Hypothesis software is presented. The interconnection was performed with the help of developed web application HypOgama. The created system uses open-source software OGAMA for recording the eye-movements of participants together with quantitative data from Hypothesis. The final part of the paper describes the integrated research system combining Hypothesis and EyeTribe.
Stachoň, Zdeněk; Šašinka, Čeněk; Doležalová, Jitka
2016-01-01
The mixed research design is a progressive methodological discourse that combines the advantages of quantitative and qualitative methods. Its possibilities of application are, however, dependent on the efficiency with which the particular research techniques are used and combined. The aim of the paper is to introduce the possible combination of Hypothesis with EyeTribe tracker. The Hypothesis is intended for quantitative data acquisition and the EyeTribe is intended for qualitative (eye-tracking) data recording. In the first part of the paper, Hypothesis software is described. The Hypothesis platform provides an environment for web-based computerized experiment design and mass data collection. Then, evaluation of the accuracy of data recorded by EyeTribe tracker was performed with the use of concurrent recording together with the SMI RED 250 eye-tracker. Both qualitative and quantitative results showed that data accuracy is sufficient for cartographic research. In the third part of the paper, a system for connecting EyeTribe tracker and Hypothesis software is presented. The interconnection was performed with the help of developed web application HypOgama. The created system uses open-source software OGAMA for recording the eye-movements of participants together with quantitative data from Hypothesis. The final part of the paper describes the integrated research system combining Hypothesis and EyeTribe. PMID:27087805
Cataracts in congenital toxoplasmosis.
Arun, Veena; Noble, A Gwendolyn; Latkany, Paul; Troia, Robert N; Jalbrzikowski, Jessica; Kasza, Kristen; Karrison, Ted; Cezar, Simone; Sautter, Mari; Greenwald, Mark J; Mieler, William; Mets, Marilyn B; Alam, Ambereen; Boyer, Kenneth; Swisher, Charles N; Roizen, Nancy; Rabiah, Peter; Del Monte, Monte A; McLeod, Rima
2007-12-01
To determine the incidence and natural history of cataracts in children with congenital toxoplasmosis. Children referred to the National Collaborative Chicago-based Congenital Toxoplasmosis Study (NCCCTS) between 1981 and 2005 were examined by ophthalmologists at predetermined times according to a specific protocol. The clinical course and treatment of patients who developed cataracts were reviewed. In the first year of life, 134 of 173 children examined were treated with pyrimethamine, sulfadiazine, and leukovorin, while the remaining 39 were not treated. Cataracts occurred in 27 eyes of 20 patients (11.6%, 95% confidence interval [7.2%, 17.3%]). Fourteen cataracts were present at birth and 13 developed postnatally. Locations of the cataracts included anterior polar (three eyes), anterior subcapsular (six eyes), nuclear (five eyes), posterior subcapsular (seven eyes), and unknown (six eyes). Thirteen cataracts were partial, nine total, and five with unknown complexity. Twelve cataracts remained stable, 12 progressed, and progression was not known for 3. Five of 27 eyes had cataract surgery, with 2 of these developing glaucoma. Sixteen eyes of 11 patients had retinal detachment and cataract. All eyes with cataracts had additional ocular lesions. In the NCCCTS cohort, 11.6% of patients were diagnosed with cataracts. There was considerable variability in the presentation, morphology, and progression of the cataracts. Associated intraocular pathology was an important cause of morbidity.
Whole eye wavefront aberrations in Mexican male subjects.
Cantú, Roberto; Rosales, Marco A; Tepichín, Eduardo; Curioca, Andrée; Montes, Victor; Bonilla, Julio
2004-01-01
To analyze the characteristics, incidence, and appearance of wavefront aberrations in undilated, normal, unoperated eyes. Eighty-eight eyes of 44 healthy male Mexican subjects (mean age 25.32 years, range 18 to 36 yr) were divided into three groups based on uncorrected visual acuity of greater than or equal to 20/20, 20/30, or 20/40. UCVA measurements were obtained using an Acuity Max computer screen chart. Wavefront aberrations were measured with the Nidek OPD-Scan ARK 10000, Ver. 1.11b. All measurements were carried out at the same center by the same technician during a single session, following manufacturer instructions. Background illumination was 3 Lux. Wavefront aberration measurements for each group were statistically analyzed using StatView; an average eye was characterized and the resulting aberrations were simulated using MATLAB. We obtained wavefront aberration maps for the 20/20 undilated normal unoperated eyes for total, low, and high order aberration coefficients. Wavefront maps for right eyes were practically the same as those for left eyes. Higher aberrations did not contribute substantially to total wavefront analysis. Average aberrations of this "normal eye" will be used as criteria to decide the necessity of wavefront-guided ablation in our facilities. We will focus on the nearly zero average of high order aberrations in this normal whole eye as a reference to be matched.
Automatic red eye correction and its quality metric
NASA Astrophysics Data System (ADS)
Safonov, Ilia V.; Rychagov, Michael N.; Kang, KiMin; Kim, Sang Ho
2008-01-01
The red eye artifacts are troublesome defect of amateur photos. Correction of red eyes during printing without user intervention and making photos more pleasant for an observer are important tasks. The novel efficient technique of automatic correction of red eyes aimed for photo printers is proposed. This algorithm is independent from face orientation and capable to detect paired red eyes as well as single red eyes. The approach is based on application of 3D tables with typicalness levels for red eyes and human skin tones and directional edge detection filters for processing of redness image. Machine learning is applied for feature selection. For classification of red eye regions a cascade of classifiers including Gentle AdaBoost committee from Classification and Regression Trees (CART) is applied. Retouching stage includes desaturation, darkening and blending with initial image. Several versions of approach implementation using trade-off between detection and correction quality, processing time, memory volume are possible. The numeric quality criterion of automatic red eye correction is proposed. This quality metric is constructed by applying Analytic Hierarchy Process (AHP) for consumer opinions about correction outcomes. Proposed numeric metric helped to choose algorithm parameters via optimization procedure. Experimental results demonstrate high accuracy and efficiency of the proposed algorithm in comparison with existing solutions.
Stonecipher, Karl G; Chia, Jenny; Onyenwenyi, Ahunna; Villanueva, Linda; Hollander, David A
2013-01-01
Background Dry eye is a multifactorial, symptomatic disease associated with ocular surface inflammation and tear film hyperosmolarity. This study was designed to assess patterns of topical cyclosporine ophthalmic emulsion 0.05% (Restasis®) use in dry eye patients and determine if there were any differences in use based on whether dry eye is physician-coded as a primary or nonprimary diagnosis. Methods Records for adult patients with a diagnosis of dry eye at an outpatient visit from January 1, 2008 to December 31, 2009 were selected from Truven Health MarketScan® Research Databases. The primary endpoint was percentage of patients with at least one primary versus no primary dry eye diagnosis who filled a topical cyclosporine prescription. Data analyzed included utilization of topical corticosteroids, oral tetracyclines, and punctal plugs. Results The analysis included 576,416 patients, accounting for 875,692 dry eye outpatient visits: 74.7% were female, 64.2% were ages 40–69 years, and 84.4% had at least one primary dry eye diagnosis. During 2008–2009, 15.9% of dry eye patients with a primary diagnosis versus 6.5% with no primary diagnosis filled at least one cyclosporine prescription. For patients who filled at least one prescription, the mean months’ supply of cyclosporine filled over 12 months was 4.44. Overall, 33.9% of dry eye patients filled a prescription for topical cyclosporine, topical corticosteroid, or oral tetracycline over 2 years. Conclusion Patients with a primary dry eye diagnosis were more likely to fill a topical cyclosporine prescription. Although inflammation is key to the pathophysiology of dry eye, most patients seeing a physician for dry eye may not receive anti-inflammatory therapies. PMID:24179335
Stonecipher, Karl G; Chia, Jenny; Onyenwenyi, Ahunna; Villanueva, Linda; Hollander, David A
2013-01-01
Dry eye is a multifactorial, symptomatic disease associated with ocular surface inflammation and tear film hyperosmolarity. This study was designed to assess patterns of topical cyclosporine ophthalmic emulsion 0.05% (Restasis®) use in dry eye patients and determine if there were any differences in use based on whether dry eye is physician-coded as a primary or nonprimary diagnosis. Records for adult patients with a diagnosis of dry eye at an outpatient visit from January 1, 2008 to December 31, 2009 were selected from Truven Health MarketScan® Research Databases. The primary endpoint was percentage of patients with at least one primary versus no primary dry eye diagnosis who filled a topical cyclosporine prescription. Data analyzed included utilization of topical corticosteroids, oral tetracyclines, and punctal plugs. The analysis included 576,416 patients, accounting for 875,692 dry eye outpatient visits: 74.7% were female, 64.2% were ages 40-69 years, and 84.4% had at least one primary dry eye diagnosis. During 2008-2009, 15.9% of dry eye patients with a primary diagnosis versus 6.5% with no primary diagnosis filled at least one cyclosporine prescription. For patients who filled at least one prescription, the mean months' supply of cyclosporine filled over 12 months was 4.44. Overall, 33.9% of dry eye patients filled a prescription for topical cyclosporine, topical corticosteroid, or oral tetracycline over 2 years. Patients with a primary dry eye diagnosis were more likely to fill a topical cyclosporine prescription. Although inflammation is key to the pathophysiology of dry eye, most patients seeing a physician for dry eye may not receive anti-inflammatory therapies.
Kumar, Prachi; Bhargava, Rahul; Arora, Yogesh C; Kaushal, Sidharth; Kumar, Manjushri
2015-01-01
Prolonged contact lens wear is often accompanied by dryness of the eyes. The aim of this study was to compare conjunctival impression cytology (CIC) and tear film tests such as tear film break up time (TBUT) and Schirmer test for dry eye evaluation in contact lens wearers and measure their correlation with dry eye symptoms. A case control study was done at three referral eye centers. The eyes of 230 contact lens users were compared to 250 eyes of age- and sex-matched controls. Participants were recruited based on their response to a questionnaire of dry eye symptoms, (Dry Eye Scoring System, DESS(©)) and measurements of TBUT, Schirmer test, and CIC was done. A correlation analysis between symptom severity and tear film tests was performed. Pearson's coefficient, R(2) > 0.5 was considered significant. As compared to controls (r (2) = 0.010), Nelson grade correlated significantly with dry eye symptoms (r (2) = 0.765), among cases. However, there was moderate correlation between dry eye symptoms, Schirmer test, and TBUT (r (2) = 0.557 and 0.530, respectively) among cases and a weak correlation among controls (r (2) = 0.130 and 0.054, respectively). The sensitivity of TBUT was 86.4%, specificity was 82.4%, positive likelihood ratio (LR) was 4.50 [95% confidence interval (CI) 3.46-5.85)], and negative LR was 0.09. The sensitivity of the Schirmer test was 48.2%, specificity 88%, LR 2.12 (95% CI 1.48-2.96), and negative LR 0.83. CIC correlates better than Schirmer and TBUT with dry eye symptoms. It may be the most appropriate test for dry-eye evaluation in contact lens wearers.
Braun, Katrin; Stach, Thomas
2017-10-01
Salps are marine planktonic chordates that possess an obligatory alternation of reproductive modes in subsequent generations. Within tunicates, salps represent a derived life cycle and are of interest in considerations of the evolutionary origin of complex anatomical structures and life history strategies. In the present study, the eyes and brains of both the sexual, aggregate blastozooid and the asexual, solitary oozooid stage of Thalia democratica (Forskål, ) were digitally reconstructed in detail based on serial sectioning for light and transmission electron microscopy. The blastozooid stage of T. democratica possesses three pigment cup eyes, situated in the anterior ventral part of the brain. The eyes are arranged in a way that the optical axes of each eye point toward different directions. Each eye is an inverse eye that consists of two different cell types: pigment cells (pigc) and rhabdomeric photoreceptor cells (prcs). The oozooid stage of T. democratica is equipped with a single horseshoe-shaped eye, positioned in the anterior dorsal part of the brain. The opening of the horseshoe-shaped eye points anteriorly. Similar to the eyes of the blastozooid, the eye of the oozooid consists of pigment cells and rhabdomeric photoreceptor cells. The rhabdomeric photoreceptor cells possess apical microvilli that form a densely packed presumably photosensitive receptor part adjacent to the concave side of the pigc. We suggest correspondences of the individual eyes in the blastozooid stage to respective parts of the single horseshoe-shaped eye in the oozooid stage and hypothesize that the differences in visual structures and brain anatomies evolved as a result of the aggregate life style of the blastozooid as opposed to the solitary life style of the oozooid. © 2017 Wiley Periodicals, Inc.
A new mapping function in table-mounted eye tracker
NASA Astrophysics Data System (ADS)
Tong, Qinqin; Hua, Xiao; Qiu, Jian; Luo, Kaiqing; Peng, Li; Han, Peng
2018-01-01
Eye tracker is a new apparatus of human-computer interaction, which has caught much attention in recent years. Eye tracking technology is to obtain the current subject's "visual attention (gaze)" direction by using mechanical, electronic, optical, image processing and other means of detection. While the mapping function is one of the key technology of the image processing, and is also the determination of the accuracy of the whole eye tracker system. In this paper, we present a new mapping model based on the relationship among the eyes, the camera and the screen that the eye gazed. Firstly, according to the geometrical relationship among the eyes, the camera and the screen, the framework of mapping function between the pupil center and the screen coordinate is constructed. Secondly, in order to simplify the vectors inversion of the mapping function, the coordinate of the eyes, the camera and screen was modeled by the coaxial model systems. In order to verify the mapping function, corresponding experiment was implemented. It is also compared with the traditional quadratic polynomial function. And the results show that our approach can improve the accuracy of the determination of the gazing point. Comparing with other methods, this mapping function is simple and valid.
Therapeutic inhibitors for the treatment of dry eye syndrome.
Rodríguez-Pomar, Candela; Pintor, Jesus; Colligris, Basilio; Carracedo, Gonzalo
2017-12-01
Dry eye disease (DED), defined as a multifactorial disease of tears and ocular surface, results in symptoms of discomfort, ocular irritation, visual disturbance and tear film instability. This syndrome is accompanied of ocular surface inflammation and it is produced by a deficient activity of the lacrimal functional unit. In addition, it is associated with systemic autoimmune diseases such as Sjögren´s Syndrome, rheumatoid arthritis, systemic lupus erythematosus and some drug administration. The treatment of dry eye disease is based on the typical signs and symptoms of dry eye, which are associated with hyperosmolarity, ocular surface inflammation, discomfort, visual disturbance, and tear film instability. Areas covered: This review is focused on synthetic drugs currently used in clinical practice, from phase III development onwards to treat the ocular surface signs and symptoms of dry eye disease. Expert opinion: The multifactorial disease and the lack of correlation between signs and symptoms imply that not all the pharmacological approaches will be successful for dry eye. The correct design of the clinical trials, with appropriate endpoints, and the type of dry eye under study are complicated but mandatory. The anti-inflammatory and secretagogues drugs are both the main compounds to currently treat the dry eye disease.
Automated eye blink detection and correction method for clinical MR eye imaging.
Wezel, Joep; Garpebring, Anders; Webb, Andrew G; van Osch, Matthias J P; Beenakker, Jan-Willem M
2017-07-01
To implement an on-line monitoring system to detect eye blinks during ocular MRI using field probes, and to reacquire corrupted k-space lines by means of an automatic feedback system integrated with the MR scanner. Six healthy subjects were scanned on a 7 Tesla MRI whole-body system using a custom-built receive coil. Subjects were asked to blink multiple times during the MR-scan. The local magnetic field changes were detected with an external fluorine-based field probe which was positioned close to the eye. The eye blink produces a field shift greater than a threshold level, this was communicated in real-time to the MR system which immediately reacquired the motion-corrupted k-space lines. The uncorrected images, using the original motion-corrupted data, showed severe artifacts, whereas the corrected images, using the reacquired data, provided an image quality similar to images acquired without blinks. Field probes can successfully detect eye blinks during MRI scans. By automatically reacquiring the eye blink-corrupted data, high quality MR-images of the eye can be acquired. Magn Reson Med 78:165-171, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.
Iáñez, Eduardo; Azorin, Jose M.; Perez-Vidal, Carlos
2013-01-01
This paper describes a human-computer interface based on electro-oculography (EOG) that allows interaction with a computer using eye movement. The EOG registers the movement of the eye by measuring, through electrodes, the difference of potential between the cornea and the retina. A new pair of EOG glasses have been designed to improve the user's comfort and to remove the manual procedure of placing the EOG electrodes around the user's eye. The interface, which includes the EOG electrodes, uses a new processing algorithm that is able to detect the gaze direction and the blink of the eyes from the EOG signals. The system reliably enabled subjects to control the movement of a dot on a video screen. PMID:23843986
NASA Technical Reports Server (NTRS)
Comstock, J. R., Jr.; Kirby, R. H.; Coates, G. D.
1985-01-01
The present study explored eye scan behavior as a function of level of subject training. Oculometric (eye scan) measures were recorded from each of ten subjects during training trials on a CRT based flight simulation task. The task developed for the study incorporated subtasks representative of specific activities performed by pilots, but which could be performed at asymptotic levels within relatively short periods of training. Changes in eye scan behavior were examined as initially untrained subjects developed skill in the task. Eye scan predictors of performance on the task were found. Examination of eye scan in proximity to selected task events revealed differences in the distribution of looks at the instruments as a function of level of training.
Recent developments on dry eye disease treatment compounds.
Colligris, Basilio; Alkozi, Hanan Awad; Pintor, Jesus
2014-01-01
Dry eye syndrome is a common tears and ocular surface multifactorial disease, described by changes in the ocular surface epithelia related to reduced tears quantity and ocular surface sensitivity, leading to inflammatory reaction. Managing the eye inflammation proved helpful to patients with dry eye disease and current treatment is based on the use of topically applied artificial tear products/lubricants, tear retention management, stimulation of tear secretion and using anti-inflammatory drugs. In this article we revise the corresponding literature and patents assembling the new treatment approaches of novel and future pharmaceutical compounds destined for the dry eye disease treatment. The most frequent categories of compounds presented are secretagogues and anti-inflammatory drugs. These compounds are the research outcome of novel therapeutic strategies designed to reduce key inflammatory pathways and restore healthy tear film.
Disk space and load time requirements for eye movement biometric databases
NASA Astrophysics Data System (ADS)
Kasprowski, Pawel; Harezlak, Katarzyna
2016-06-01
Biometric identification is a very popular area of interest nowadays. Problems with the so-called physiological methods like fingerprints or iris recognition resulted in increased attention paid to methods measuring behavioral patterns. Eye movement based biometric (EMB) identification is one of the interesting behavioral methods and due to the intensive development of eye tracking devices it has become possible to define new methods for the eye movement signal processing. Such method should be supported by an efficient storage used to collect eye movement data and provide it for further analysis. The aim of the research was to check various setups enabling such a storage choice. There were various aspects taken into consideration, like disk space usage, time required for loading and saving whole data set or its chosen parts.
Waring, George O
2009-10-01
To describe recent technological additions to the NIDEK CXIII and Quest excimer lasers. A summary article with data from previous published studies outlining the benefits of newer technology. The addition of a 1-kHz infrared eye tracker decreased the spread of laser spot placement from a mean of 228.79 microm without a tracker to 38.47 microm with the eye tracker. The addition of real-time torsion error correction produced a statistically significantly lower cylinder dispersion, mean manifest refractive cylinder, and error of angle postoperatively in eyes that underwent LASIK. The incorporation of an ultrahigh speed eye tracker and active cyclotorsion correction surpasses the minimal technology criteria required for accurate wavefront-based ablations. Copyright 2009, SLACK Incorporated.
ERIC Educational Resources Information Center
Shimizu, Hirofumi; Yoon, Soyoung; McDonough, Christopher S.
2010-01-01
We taught seven preschoolers with developmental disabilities to point-and-click with a computer mouse. The computer-based training program consisted of three parts, based on a task analysis of the behavioral prerequisites to point-and-click. Training 1 was designed to shape moving the mouse. Training 2 was designed to build eye-hand coordination…
Searching for unity: Real-world versus item-based visual search in age-related eye disease.
Crabb, David P; Taylor, Deanna J
2017-01-01
When studying visual search, item-based approaches using synthetic targets and distractors limit the real-world applicability of results. Everyday visual search can be impaired in patients with common eye diseases like glaucoma and age-related macular degeneration. We highlight some results in the literature that suggest assessment of real-word search tasks in these patients could be clinically useful.
Epidemiology of pediatric ocular trauma in the Chaoshan Region, China, 2001-2010.
Cao, He; Li, Liping; Zhang, Mingzhi; Li, Hongni
2013-01-01
Ocular trauma is the leading cause of monocular visual disability and noncongenital unilateral blindness in children. This study describes the epidemiology and medical care associated with nonfatal pediatric (≤ 17 years of age) eye injury-related hospitalization in the largest industrial base for plastic toy production in China. A population-based retrospective study of patients hospitalized for ocular and orbital trauma in the ophthalmology departments of 3 major tertiary hospitals from 1st January 2001 to 31st December 2010 was performed. The study included 1035 injured eyes from 1018 patients over a 10-year period: 560 (54.1%) eyes exhibited open globe injuries, 402 (38.8%) eyes suffered closed globe injuries, 10 (1.0%) eyes suffered chemical injuries and 8 (0.8%) eyes exhibited thermal injuries, representing an average annual hospitalization rate of 0.37 per 10,000 (95% confidence interval [CI], 0.36-0.38) due to pediatric eye injury in the Chaoshan region. The mean patient age was 9.2 ± 4.4 years with a male-to-female ratio of 3.3:1 (P = 0.007). Children aged 6 to 11 years accounted for the highest percentage (40.8%, 416/1018) of hospitalization, 56.7% (236/416) of whom were hospitalized for open globe wounds. Injury occurred most frequently at home (73.1%). Open globe wounds cost the single most expensive financial burden (60.8%) of total charges with $998 ± 702 mean charges per hospitalization. Open globe wounds occurred at home are earmarked for the priorities to prevention strategies. Higher public awareness of protecting primary schoolchildren from home-related eye injuries should be strengthened urgently by legislation or regulation since the traditional industrial mode seems to remain the pattern for the foreseeable future. Further research that provide detailed information on the specific inciting agents of pediatric eye injuries are recommended for facilitating the development and targeting of appropriate injury prevention initiatives.
A Novel Combination Therapy for Patients With Dry Eye Disease: A Pilot Study.
Smith, Will; McMahon, David; Nymark, Maria
2018-05-01
Context • Approximately 25% of the US population suffers from dry eyes or some abnormality of the exposed ocular surface. Investigation of effective modalities for their management is needed. Objective • The study intended to examine the efficacy of a proprietary, daily, Dry Eye Protocol consisting of daily use of a moist, heated, ocular compress and intake of an omega-3 dietary supplement in treatment of ocular surface disease. Design • The research team designed a 4-wk, clinically based, open-label, multicenter cohort study. Setting • The study took place at 6 private eye care practices throughout the United States: Beverly Hills, CA, USA; San Diego, CA, USA; Sunnyvale, CA, USA; Park City, UT, USA; Tarpon Spring, FL, USA; and Kennewick, WA, USA. Participants • Participants were adults between 18 and 75 y of age who had established ocular surface disease based on clinical findings and the results of testing using the ocular surface disease index (OSDI). Intervention • For period of 30 d, participants used a combined daily protocol that included (1) application of a moist, heated, eye compress and (2) a nutritional therapy via an omega-3 supplement in an oral triglyceride form. Outcome Measures • Measures included the OSDI and a test of tear break-up time (TBUT). Results • Of the original 35 participants, 33 completed the 4-wk protocol. The participants using the proprietary Dry Eye Protocol showed significant improvements from baseline, demonstrated by a 49% decrease in OSDI scores (P = .0015); and 46% of participants reported becoming asymptomatic of dry eye symptoms. A significant improvement was also observed in TBUT, increasing from 3.0 to 5.4 s. Conclusions • Daily use of the proprietary Dry Eye Protocol that included a high dosage of triglyceride omega-3 and use of a moist, heated, compress daily showed significant improvement for participants in OSDI and TBUT and should be considered to be a first-line therapy for patients with dry eye disease.
Epidemiology of Pediatric Ocular Trauma in the Chaoshan Region, China, 2001–2010
Cao, He; Li, Liping; Zhang, Mingzhi; Li, Hongni
2013-01-01
Background Ocular trauma is the leading cause of monocular visual disability and noncongenital unilateral blindness in children. This study describes the epidemiology and medical care associated with nonfatal pediatric (≤17 years of age) eye injury-related hospitalization in the largest industrial base for plastic toy production in China. Methods A population-based retrospective study of patients hospitalized for ocular and orbital trauma in the ophthalmology departments of 3 major tertiary hospitals from 1st January 2001 to 31st December 2010 was performed. Results The study included 1035 injured eyes from 1018 patients over a 10-year period: 560 (54.1%) eyes exhibited open globe injuries, 402 (38.8%) eyes suffered closed globe injuries, 10 (1.0%) eyes suffered chemical injuries and 8 (0.8%) eyes exhibited thermal injuries, representing an average annual hospitalization rate of 0.37 per 10,000 (95% confidence interval [CI], 0.36–0.38) due to pediatric eye injury in the Chaoshan region. The mean patient age was 9.2±4.4 years with a male-to-female ratio of 3.3∶1 (P = 0.007). Children aged 6 to 11 years accounted for the highest percentage (40.8%, 416/1018) of hospitalization, 56.7% (236/416) of whom were hospitalized for open globe wounds. Injury occurred most frequently at home (73.1%). Open globe wounds cost the single most expensive financial burden (60.8%) of total charges with $998±702 mean charges per hospitalization. Conclusions Open globe wounds occurred at home are earmarked for the priorities to prevention strategies. Higher public awareness of protecting primary schoolchildren from home-related eye injuries should be strengthened urgently by legislation or regulation since the traditional industrial mode seems to remain the pattern for the foreseeable future. Further research that provide detailed information on the specific inciting agents of pediatric eye injuries are recommended for facilitating the development and targeting of appropriate injury prevention initiatives. PMID:23593323
Voje, Kjetil L; Hansen, Thomas F
2013-02-01
Julian Huxley showed that within-species (static) allometric (power-law) relations can arise from proportional growth regulation with the exponent in the power law equaling the factor of proportionality. Allometric exponents may therefore be hard to change and act as constraints on the independent evolution of traits. In apparent contradiction to this, many empirical studies have concluded that static allometries are evolvable. Many of these studies have been based, however, on a broad definition of allometry that includes any monotonic shape change with size, and do not falsify the hypothesis of constrained narrow-sense allometry. Here, we present the first phylogenetic comparative study of narrow-sense allometric exponents based on a reanalysis of data on eye span and body size in stalk-eyed flies (Diopsidae). Consistent with a role in sexual selection, we found strong evidence that male slopes were tracking "optima" based on sexual dimorphism and relative male trait size. This tracking was slow, however, with estimated times of 2-3 million years for adaptation to exceed ancestral influence on the trait. Our results are therefore consistent with adaptive evolution on million-year time scales, but cannot rule out that static allometry may act as a constraint on eye-span adaptation at shorter time scales. © 2012 The Author(s). Evolution© 2012 The Society for the Study of Evolution.
Gaze Estimation for Off-Angle Iris Recognition Based on the Biometric Eye Model
DOE Office of Scientific and Technical Information (OSTI.GOV)
Karakaya, Mahmut; Barstow, Del R; Santos-Villalobos, Hector J
Iris recognition is among the highest accuracy biometrics. However, its accuracy relies on controlled high quality capture data and is negatively affected by several factors such as angle, occlusion, and dilation. Non-ideal iris recognition is a new research focus in biometrics. In this paper, we present a gaze estimation method designed for use in an off-angle iris recognition framework based on the ANONYMIZED biometric eye model. Gaze estimation is an important prerequisite step to correct an off-angle iris images. To achieve the accurate frontal reconstruction of an off-angle iris image, we first need to estimate the eye gaze direction frommore » elliptical features of an iris image. Typically additional information such as well-controlled light sources, head mounted equipment, and multiple cameras are not available. Our approach utilizes only the iris and pupil boundary segmentation allowing it to be applicable to all iris capture hardware. We compare the boundaries with a look-up-table generated by using our biologically inspired biometric eye model and find the closest feature point in the look-up-table to estimate the gaze. Based on the results from real images, the proposed method shows effectiveness in gaze estimation accuracy for our biometric eye model with an average error of approximately 3.5 degrees over a 50 degree range.« less
A case of unilateral phthiriasis palpebrarum infestation involving the left eye.
Ashraf, Mohammad; Waris, Abdul; Kumar, Ashwini; Akhtar, Nahid
2014-06-06
Phthiriasis palpebrarum is a rare cause of eyelid infestation. We report a case of unilateral phthiriasis palpebrarum. A 28-year-old man presented with moderate itching associated with lacrimation and irritation in the left eye. The initial evaluation of the patient revealed multiple white dots on the left upper eyelashes. Slit-lamp examination revealed multiple nits attached to the base and shaft of the cilia. There was no hyperaemia or discharge present in the conjunctiva and the cornea was clear and shiny. The right eye was perfectly normal. The patient was treated with moxifloxacin eye ointment and was completely cured in 1 week. 2014 BMJ Publishing Group Ltd.
An experimental model of an indigenous BCI based system to help disabled people to communicate
NASA Astrophysics Data System (ADS)
Kabir, Kazi Sadman; Rahman, Chowdhury M. Abid; Farayez, Araf; Ferdous, Mahbuba
2017-12-01
In this paper a Brain Computer Interface (BCI) system has been proposed to help patients suffering from motor disease, paralysis or locked in syndrome to communicate via eye blinking. In this proposed BCI system EEG data is fetched by NeuroSky Headset and then analyzed by the help of WPF (Windows Presentation Foundation) based serial monitor to detect the EEG signal when the eye gives a blink. This detection of eye blinking can be used to select predefined texts and those texts can be converted to speech. The experimental result shows that this system can be used as an effective and efficient tool to communicate through brain.
Mechanisms and management of dry eye in cataract surgery patients.
Sutu, Christine; Fukuoka, Hideki; Afshari, Natalie A
2016-01-01
To provide a summary of the mechanisms that may cause dry eye after cataract surgery and discuss available and upcoming treatment modalities. Development or worsening of dry eye symptoms after cataract surgery is multifactorial with corneal nerve transection, inflammation, goblet cell loss, and meibomian gland dysfunction commonly cited as underlying disorders. With increasing awareness of the prevalence of dry eye disease, current surgical techniques are being analyzed for their contribution to the issue. Although many classic interventions, such as artificial tears and anti-inflammatory drops, remain first-line treatment options, they may not adequately address abnormalities of the tear film. The trend has been to create new drugs and technologies that target meibomian gland deficiencies and restore goblet cell numbers. Therapy for postoperative dry eye symptoms should be determined based on symptom severity and which underlying cause is most prominent at a given time. Patients with high-level risk factors for dry eye should be evaluated preoperatively to determine whether they have preexisting dry eye disease or if they are susceptible to developing disease after surgery.
Short-term memory across eye blinks.
Irwin, David E
2014-01-01
The effect of eye blinks on short-term memory was examined in two experiments. On each trial, participants viewed an initial display of coloured, oriented lines, then after a retention interval they viewed a test display that was either identical or different by one feature. Participants kept their eyes open throughout the retention interval on some blocks of trials, whereas on others they made a single eye blink. Accuracy was measured as a function of the number of items in the display to determine the capacity of short-term memory on blink and no-blink trials. In separate blocks of trials participants were instructed to remember colour only, orientation only, or both colour and orientation. Eye blinks reduced short-term memory capacity by approximately 0.6-0.8 items for both feature and conjunction stimuli. A third, control, experiment showed that a button press during the retention interval had no effect on short-term memory capacity, indicating that the effect of an eye blink was not due to general motoric dual-task interference. Eye blinks might instead reduce short-term memory capacity by interfering with attention-based rehearsal processes.
Collins, Melanie M; Johnson, Ian J M; Clifford, Elaine; Birchall, John P; O'Donoghue, Gerald M
2003-04-01
The objective was to evaluate the preoperative postural stability of acoustic neuroma patients using sway magnetometry. Prospective two-center study. Fifty-one patients (mean age, 53 years) diagnosed with unilateral acoustic neuroma on magnetic resonance imaging at two tertiary referral centers were studied. Preoperatively, each patient had sway patterns (with eyes open and with eyes closed, and standing on foam) recorded for 120 seconds by sway magnetometry. Path length for 30 seconds was calculated. The Romberg coefficient (path length with eyes open divided by path length with eyes closed) was calculated. Forty-four percent of patients had abnormal path lengths with eyes open, and 49% with eyes closed. The Romberg coefficients were significantly lower than normal (P <.001; 95% CI, 0.19-0.87). Mean Romberg coefficient was 0.59 (normal value = 0.73), and all patients had a coefficient of less than 1. Half of preoperative acoustic neuroma patients are unsteady, exhibiting abnormal sway patterns based on path length measurements. The increase in sway path length demonstrable in normal subjects with eyes closed was significantly exaggerated in patients with acoustic neuroma.
Huang, David; Tang, Maolong; Wang, Li; Zhang, Xinbo; Armour, Rebecca L.; Gattey, Devin M.; Lombardi, Lorinna H.; Koch, Douglas D.
2013-01-01
Purpose: To use optical coherence tomography (OCT) to measure corneal power and improve the selection of intraocular lens (IOL) power in cataract surgeries after laser vision correction. Methods: Patients with previous myopic laser vision corrections were enrolled in this prospective study from two eye centers. Corneal thickness and power were measured by Fourier-domain OCT. Axial length, anterior chamber depth, and automated keratometry were measured by a partial coherence interferometer. An OCT-based IOL formula was developed. The mean absolute error of the OCT-based formula in predicting postoperative refraction was compared to two regression-based IOL formulae for eyes with previous laser vision correction. Results: Forty-six eyes of 46 patients all had uncomplicated cataract surgery with monofocal IOL implantation. The mean arithmetic prediction error of postoperative refraction was 0.05 ± 0.65 diopter (D) for the OCT formula, 0.14 ± 0.83 D for the Haigis-L formula, and 0.24 ± 0.82 D for the no-history Shammas-PL formula. The mean absolute error was 0.50 D for OCT compared to a mean absolute error of 0.67 D for Haigis-L and 0.67 D for Shammas-PL. The adjusted mean absolute error (average prediction error removed) was 0.49 D for OCT, 0.65 D for Haigis-L (P=.031), and 0.62 D for Shammas-PL (P=.044). For OCT, 61% of the eyes were within 0.5 D of prediction error, whereas 46% were within 0.5 D for both Haigis-L and Shammas-PL (P=.034). Conclusions: The predictive accuracy of OCT-based IOL power calculation was better than Haigis-L and Shammas-PL formulas in eyes after laser vision correction. PMID:24167323
Nationwide incidence of blindness in South Korea: a 12-year study from 2002 to 2013.
Rim, Tyler Hyungtaek; Kim, Dong Wook; Chung, Eun Jee; Kim, Sung Soo
2017-11-01
Blindness is an important public health issue. The background of the study is to determine the incidence of blindness in South Korea. Nationwide population-based retrospective study. All individuals from South Korea (n = 47 516 098). Patients confirmed with legal blindness based on the worse-seeing and better-seeing eyes between 1 January 2002 and 31 December 2013 were included. The Korean National Health Insurance Service (KNHIS) database was used. Using the World Health Organization definition, blindness was defined as best-corrected visual acuity in the worse-seeing and better-seeing eyes of <20/400. The mean incidence of blindness during the 12-year period was estimated. The population of South Korea was estimated using census data in 2005 and 2010. The total number of legal blindness cases in the KNHIS database. We identified 195 004 and 20 492 cases of newly developed legal blindness based on the worse-seeing and better-seeing eyes, respectively, and the mean incidences of blindness were 34.2 and 3.6 cases/100 000 person-years, respectively. The prevalence of blindness based on the worse-seeing and better-seeing eyes was 425.3 and 57.7 cases/100 000 persons, respectively. The incidence of blindness based on the worse-seeing eye was higher in men than in women overall. Additionally, the incidence increased with age and showed a decreasing trend from 2002 to 2013. The prevalence of blindness showed an increasing trend from 2002 to 2013. The findings of our study will help in the assessment of the blindness-related socio-economic burden and in healthcare planning. © 2017 Royal Australian and New Zealand College of Ophthalmologists.
Hark, Lisa A; Leiby, Benjamin E; Waisbourd, Michael; Myers, Jonathan S; Fudemberg, Scott J; Mantravadi, Anand V; Dai, Yang; Gilligan, John P; Resende, Arthur F; Katz, L Jay
2017-08-01
To evaluate rates of adherence to free follow-up eye exam appointments among participants in the Philadelphia Glaucoma Detection and Treatment Project. Ophthalmologists and testing equipment were brought directly to participants at risk for glaucoma at 43 community sites in Philadelphia. Those diagnosed with glaucoma-related pathology were recommended to return for follow-up to be reexamined on site. Rates of adherence and clinical and demographic risk factors for adherence were evaluated. Five hundred thirty-one participants were diagnosed with glaucoma-related conditions and recommended to attend community-based follow-up exams. Follow-up adherence rate was 61.2% (n=325/531). Significant factors associated with greater eye exam appointment adherence, based on our univariable analysis, included final diagnosis of glaucoma (risk ratio [RR]=1.33; 95% confidence interval [CI], 1.13-1.57), male sex (RR=1.19; 95% CI, 1.04-1.36), white race (RR=1.26; 95% CI, 1.08-1.48), age (RR=1.17; 95% CI, 1.00-1.37) recommendation for glaucoma medication (RR=1.52; 95% CI, 1.35-1.71), recommendation for laser peripheral iridotomy (RR=1.18; 95% CI, 1.02-1.35), diagnosis of age-related macular degeneration (RR=1.42; 95% CI, 1.13-1.77) and an increased intraocular pressure (>22 mm Hg in the worse eye) (RR=1.23; 95% CI, 1.06-1.42). On the basis of our multivariable model, diagnosis, sex, and recommended glaucoma medications were significantly associated with follow-up adherence. This study demonstrates that individuals living in underserved urban communities would take advantage of free eye exams in community sites and return for follow-up eye exams in these same settings. Future studies could investigate interventions to improve eye exam appointment adherence in community-based settings to detect glaucoma-eye conditions.
Bolch, W E; Dietze, G; Petoussi-Henss, N; Zankl, M
2015-06-01
Based upon recent epidemiological studies of ocular exposure, the Main Commission of the International Commission on Radiological Protection (ICRP) in ICRP Publication 118 states that the threshold dose for radiation-induced cataracts is now considered to be approximately 0.5 Gy for both acute and fractionated exposures. Consequently, a reduction was also recommended for the occupational annual equivalent dose to the lens of the eye from 150 mSv to 20 mSv, averaged over defined periods of 5 years. To support ocular dose assessment and optimisation, Committee 2 included Annex F within ICRP Publication 116 . Annex F provides dose coefficients - absorbed dose per particle fluence - for photon, electron, and neutron irradiation of the eye and lens of the eye using two dosimetric models. The first approach uses the reference adult male and female voxel phantoms of ICRP Publication 110. The second approach uses the stylised eye model of Behrens et al., which itself is based on ocular dimensional data given in Charles and Brown. This article will review the data and models of Annex F with particular emphasis on how these models treat tissue regions thought to be associated with stem cells at risk. © The International Society for Prosthetics and Orthotics Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Rapid assessment method for prevalence and intensity of Loa loa infection.
Takougang, Innocent; Meremikwu, Martin; Wandji, Samuel; Yenshu, Emmanuel V.; Aripko, Ben; Lamlenn, Samson B.; Eka, Braide L.; Enyong, Peter; Meli, Jean; Kale, Oladele; Remme, Jan H.
2002-01-01
OBJECTIVE: To assess the validity of observations on eye worm and Calabar swellings for the rapid assessment of the prevalence and intensity of loiasis at the community level. METHOD: A total of 12895 individuals over the age of 15 years living in 102 communities in Cameroon and Nigeria took part in the study. A standardized questionnaire was administered to participants from whom finger-prick blood samples were collected and examined for Loa loa microfilariae. Rapid assessments of the prevalence and intensity of loiasis were made on the basis of a history of eye worm or Calabar swellings. FINDINGS: There was a strong correlation between the indices of the rapid assessment procedures and the parasitological indices of L. loa endemicity. The rapid assessment indices were effective in diagnosing high-risk communities (sensitivity 94-100%; specificity 66-92%). The highest sensitivity (100%) and specificity (92%) were obtained with a rapid assessment procedure based on a history of eye worm lasting 1-7 days together with confirmation by the guided recognition of a photograph of adult L. loa in the eye. CONCLUSION: Rapid assessment of the prevalence and intensity of loiasis at the community level can be achieved using a procedure based on the history of eye worm lasting 1-7 days together with confirmation by the guided recognition of a photograph of an adult L. loa in the eye. PMID:12481206
Improving access to eye health services in rural Timor-Leste.
Pereira, Sara M; Blignault, Ilse; du Toit, Renee; Ramke, Jacqueline
2012-01-01
Delivering eye health services to people in rural areas, especially in fragile, post-conflict countries, is a major challenge. This article reports on the implementation and evaluation of an innovative district-based outreach service. The main project partners were the Timor-Leste Ministry of Health and an international non-government organization, with assistance from a local non-government organization. An eye care nurse in Covalima District, a remote location 178 km from Timor-Leste's capital, Dili, was provided with a motor-bike for transport and regular support for outreach eye services to sub-district facilities. Data collected over the first year of operation were examined and included: services provided, spectacles dispensed, health promotion activities conducted and the cost of providing these. The project was also evaluated for its relevance, effectiveness, efficiency, impact and sustainability. In the first 12 months, 55 outreach visits were conducted across the district's seven sub-districts during which 1405 people received vision screening, and 777 spectacles were dispensed. In addition to meeting the five evaluation criteria, compared with the hospital-based eye clinic the outreach service resulted in significantly greater gender equity among eye health service beneficiaries. This pilot project demonstrates what can be achieved when a Ministry of Health (central and district level) and non-government organizations (international and local) work in partnership to support a dedicated health care provider.
Heo, Hwan; Lee, Won Oh; Shin, Kwang Yong; Park, Kang Ryoung
2014-05-15
We propose a new method for measuring the degree of eyestrain on 3D stereoscopic displays using a glasses-type of eye tracking device. Our study is novel in the following four ways: first, the circular area where a user's gaze position exists is defined based on the calculated gaze position and gaze estimation error. Within this circular area, the position where edge strength is maximized can be detected, and we determine this position as the gaze position that has a higher probability of being the correct one. Based on this gaze point, the eye foveation model is defined. Second, we quantitatively evaluate the correlation between the degree of eyestrain and the causal factors of visual fatigue, such as the degree of change of stereoscopic disparity (CSD), stereoscopic disparity (SD), frame cancellation effect (FCE), and edge component (EC) of the 3D stereoscopic display using the eye foveation model. Third, by comparing the eyestrain in conventional 3D video and experimental 3D sample video, we analyze the characteristics of eyestrain according to various factors and types of 3D video. Fourth, by comparing the eyestrain with or without the compensation of eye saccades movement in 3D video, we analyze the characteristics of eyestrain according to the types of eye movements in 3D video. Experimental results show that the degree of CSD causes more eyestrain than other factors.
Study of multi-channel optical system based on the compound eye
NASA Astrophysics Data System (ADS)
Zhao, Yu; Fu, Yuegang; Liu, Zhiying; Dong, Zhengchao
2014-09-01
As an important part of machine vision, compound eye optical systems have the characteristics of high resolution and large FOV. By applying the compound eye optical systems to target detection and recognition, the contradiction between large FOV and high resolution in the traditional single aperture optical systems could be solved effectively and also the parallel processing ability of the optical systems could be sufficiently shown. In this paper, the imaging features of the compound eye optical systems are analyzed. After discussing the relationship between the FOV in each subsystem and the contact ratio of the FOV in the whole system, a method to define the FOV of the subsystem is presented. And a compound eye optical system is designed, which is based on the large FOV synthesized of multi-channels. The compound eye optical system consists with a central optical system and array subsystem, in which the array subsystem is used to capture the target. The high resolution image of the target could be achieved by the central optical system. With the advantage of small volume, light weight and rapid response speed, the optical system could detect the objects which are in 3km and FOV of 60°without any scanning device. The objects in the central field 2w=5.1°could be imaged with high resolution so that the objects could be recognized.
Gaze-contingent displays: a review.
Duchowski, Andrew T; Cournia, Nathan; Murphy, Hunter
2004-12-01
Gaze-contingent displays (GCDs) attempt to balance the amount of information displayed against the visual information processing capacity of the observer through real-time eye movement sensing. Based on the assumed knowledge of the instantaneous location of the observer's focus of attention, GCD content can be "tuned" through several display processing means. Screen-based displays alter pixel level information generally matching the resolvability of the human retina in an effort to maximize bandwidth. Model-based displays alter geometric-level primitives along similar goals. Attentive user interfaces (AUIs) manage object- level entities (e.g., windows, applications) depending on the assumed attentive state of the observer. Such real-time display manipulation is generally achieved through non-contact, unobtrusive tracking of the observer's eye movements. This paper briefly reviews past and present display techniques as well as emerging graphics and eye tracking technology for GCD development.
SPECTRAL DOMAIN OPTICAL COHERENCE TOMOGRAPHY FINDINGS IN MACULA-INVOLVING CYTOMEGALOVIRUS RETINITIS.
Gupta, Mrinali P; Patel, Sarju; Orlin, Anton; Marlow, Elizabeth; Chee, Ru-Ik; Nadelmann, Jennifer; Chan, R V Paul; DʼAmico, Donald J; Kiss, Szilard
2018-05-01
To evaluate the microstructural features of cytomegalovirus (CMV) retinitis by spectral domain optical coherence tomography (OCT). Subjects were patients with macula-involving CMV retinitis with OCT imaging. The leading edge of retinitis in the macula was identified based on fundus imaging, and OCT findings were longitudinally evaluated in three areas: within the area of active retinitis, at the leading edge of retinitis, and just beyond the leading edge of retinitis. Optical coherence tomography imaging of macular CMV retinitis identified vitreous cells in 10 eyes (100%), posterior vitreous detachment in four eyes (40%), broad-based vitreomacular traction in one eye (10%), epiretinal membrane in eight eyes (80%), and lamellar hole-associated epiretinal proliferation associated with an atrophic hole in one eye (10%). Retinal architectural disruption, disruption of inner retinal layers, disruption of the external limiting membrane, and ellipsoid zone abnormalities were noted within the area of retinitis in all eyes and decreased in frequency and severity at and beyond the leading edge of retinitis, although all 10 eyes (100%) exhibited one of these abnormalities, especially outer retinal microabnormalities, beyond the leading edge of retinitis. Microstructural abnormalities were frequently noted on OCT of CMV retinitis, including within the retina beyond the leading edge of retinitis identified by corresponding fundus imaging. Outer retinal abnormalities were noted more frequently than inner retinal abnormalities beyond the leading edge of retinitis. These findings provide insight into the effects of CMV retinitis on retinal microstructure and potentially on vision and highlight the potential utility of OCT for monitoring microprogression of macula-involving CMV retinitis.
Omar, Artur; Kadesjö, Nils; Palmgren, Charlotta; Marteinsdottir, Maria; Segerdahl, Tony; Fransson, Annette
2017-03-20
In accordance with recommendations by the International Commission on Radiological Protection, the current European Basic Safety Standards has adopted a reduced occupational eye lens dose limit of 20 mSv yr -1 . The radiation safety implications of this dose limit is of concern for clinical staff that work with relatively high dose x-ray angiography and interventional radiology. Presented in this work is a thorough assessment of the occupational eye lens dose based on clinical measurements with active personal dosimeters worn by staff during various types of procedures in interventional radiology, cardiology and neuroradiology. Results are presented in terms of the estimated equivalent eye lens dose for various medical professions. In order to compare the risk of exceeding the regulatory annual eye lens dose limit for the widely different clinical situations investigated in this work, the different medical professions were separated into categories based on their distinct work pattern: staff that work (a) regularly beside the patient, (b) in proximity to the patient and (c) typically at a distance from the patient. The results demonstrate that the risk of exceeding the annual eye lens dose limit is of concern for staff category (a), i.e. mainly the primary radiologist/cardiologist. However, the results also demonstrate that the risk can be greatly mitigated if radiation protection shields are used in the clinical routine. The results presented in this work cover a wide range of clinical situations, and can be used as a first indication of the risk of exceeding the annual eye lens dose limit for staff at other medical centres.
Galindo-Ferreiro, Alicia; De Miguel-Gutierrez, Julita; González-Sagrado, Manuel; Galvez-Ruiz, Alberto; Khandekar, Rajiv; Schellini, Silvana; Galindo-Alonso, Julio
2017-01-01
To present a method of screening for irregular astigmatism with an autorefractor and its determinants compared to corneal topography. This cross-sectional validity study was conducted in 2013 at an eye hospital in Spain. A tabletop autorefractor (test 1) was used to measure the refractive status of the anterior surface of the cornea at two corneal meridians of each eye. Then corneal topography (test 2) and Bogan's classification was used to group eyes into those with regular or no astigmatism (GRI) and irregular astigmatism (GRII). Test 1 provided a single absolute value for the greatest cylinder difference (Vr). The receiver operating characteristic (ROC) were plotted for the Vr values measured by test 1 for GRI and GRII eyes. On the basis a Vr value of 1.25 D as cut off, sensitivity, specificity were also calculated. The study sample was comprised of 260 eyes (135 patients). The prevalence of irregular astigmatism was 42% [95% confidence interval (CI): 36, 48]. Based on test 2, there were 151 eyes in GRI and 109 eyes in GRII. The median Vr was 0.75 D (25% quartile, 0.5 D) for GRI and 1.75 D (25% quartile, 1.25 D) for GRII. The area under curve was 0.171 for GRI and 0.83 for GRII. The sensitivity of test I was 78.1% and the specificity was 76.1%. A conventional autorefractor can be effective as a first level screening method to detect irregular corneal astigmatism in places where corneal topography facilities are not available.
Precise measurement of scleral radius using anterior eye profilometry.
Jesus, Danilo A; Kedzia, Renata; Iskander, D Robert
2017-02-01
To develop a new and precise methodology to measure the scleral radius based on anterior eye surface. Eye Surface Profiler (ESP, Eaglet-Eye, Netherlands) was used to acquire the anterior eye surface of 23 emmetropic subjects aged 28.1±6.6years (mean±standard deviation) ranging from 20 to 45. Scleral radius was obtained based on the approximation of the topographical scleral data to a sphere using least squares fitting and considering the axial length as a reference point. To better understand the role of scleral radius in ocular biometry, measurements of corneal radius, central corneal thickness, anterior chamber depth and white-to-white corneal diameter were acquired with IOLMaster 700 (Carl Zeiss Meditec AG, Jena, Germany). The estimated scleral radius (11.2±0.3mm) was shown to be highly precise with a coefficient of variation of 0.4%. A statistically significant correlation between axial length and scleral radius (R 2 =0.957, p<0.001) was observed. Moreover, corneal radius (R 2 =0.420, p<0.001), anterior chamber depth (R 2 =0.141, p=0.039) and white-to-white corneal diameter (R 2 =0.146, p=0.036) have also shown statistically significant correlations with the scleral radius. Lastly, no correlation was observed comparing scleral radius to the central corneal thickness (R 2 =0.047, p=0.161). Three-dimensional topography of anterior eye acquired with Eye Surface Profiler together with a given estimate of the axial length, can be used to calculate the scleral radius with high precision. Copyright © 2016 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Luft, Nikolaus; Hirnschall, Nino; Farrokhi, Sanaz; Findl, Oliver
2015-08-01
To assess whether anterior chamber depth (ACD) measurements in pseudophakic eyes obtained with partial coherence interferometry (PCI) and optical low-coherence reflectometry (OLCR) devices can be used interchangeably. Vienna Institute for Research in Ocular Surgery, A Karl Landsteiner Institute, Hanusch Hospital, Vienna, Austria. Prospective case series. The ACD measurements in 1 eye of each pseudophakic patient were performed with the PCI-based ACMaster device and the OLCR-based Lenstar LS900 device at least 1 day postoperatively. The study comprised 65 eyes of 65 patients with a mean age of 71.7 years ± 9.0 (SD) (range 39 to 91 years). In 15 eyes, no valid ACD readings could be obtained with the OLCR device. No obvious reason for these measurement failures was identified; however, tear-film alterations shortly after surgery were suspected. No significant difference in the mean ACD in the remaining 50 eyes was found between PCI measurements (5019 ± 660 μm; range 4008 to 6181 μm) and OLCR measurements (5015 ± 663 μm; range 4017 to 6163 μm) (P = .06). Three (6%) of 50 measurements were not within the 95% limits of agreement in the Bland-Altman analysis. Pseudophakic ACD measurements with the PCI and OLCR devices can be used interchangeably. The OLCR device proved to be more user-friendly and faster; however, in a substantial number of eyes, no usable values were obtainable. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Measuring the effect of multiple eye fixations on memory for visual attributes.
Palmer, J; Ames, C T
1992-09-01
Because of limited peripheral vision, many visual tasks depend on multiple eye fixations. Good performance in such tasks demonstrates that some memory must survive from one fixation to the next. One factor that must influence performance is the degree to which multiple eye fixations interfere with the critical memories. In the present study, the amount of interference was measured by comparing visual discriminations based on multiple fixations to visual discriminations based on a single fixation. The procedure resembled partial report, but used a discrimination measure. In the prototype study, two lines were presented, followed by a single line and a cue. The cue pointed toward one of the positions of the first two lines. Observers were required to judge if the single line in the second display was longer or shorter than the cued line of the first display. These judgments were used to estimate a length threshold. The critical manipulation was to instruct observers either to maintain fixation between the lines of the first display or to fixate each line in sequence. The results showed an advantage for multiple fixations despite the intervening eye movements. In fact, thresholds for the multiple-fixation condition were nearly as good as those in a control condition where the lines were foveally viewed without eye movements. Thus, eye movements had little or no interfering effect in this task. Additional studies generalized the procedure and the stimuli. In conclusion, information about a variety of size and shape attributes was remembered with essentially no interference across eye fixations.
Model of the Human Eye Based on ABCD Matrix
NASA Astrophysics Data System (ADS)
González, G. Díaz; Castillo, M. David Iturbe
2008-04-01
At the moment several models of the human eye exist, nevertheless the gradient index models of the human lens (crystalline) have received little attention in optometry and vision sciences, although they consider how the refractive index and the refracting power can change with the accommodation. On the other hand, in study fields like ophthalmology and optometry, exist cases where there is a lack of information about the factors that influence the change of refractive power and therefore the focal length of the eye. By such reason, in this paper we present a model of the human eye based on the ABCD matrix in order to describe the propagation of light rays, that can be understood by professional people in optics, ophthalmology and optometry, and the dispersions of the different ocular mediums are taken into account,. The aim of the model is to obtain data about the refractive power of the eye under different considerations, such as: changes in wavelength, radius of curvature and thicknesses of the ocular mediums. We present results of simulations in Matlab of our model, assuming that the object is punctual and is placed to a certain distance of the eye, and considering at the beginning to the crystalline like a medium with fixed refractive index, and after like a gradient lens. By means of graphs, we show the total refractive power of the eye and its form and type of dependence with respect to variations in radius of curvature and thicknesses of the cornea and crystalline, as well as variations in the thickness of the previous and later cameras.
Sunglasses with thick temples and frame constrict temporal visual field.
Denion, Eric; Dugué, Audrey Emmanuelle; Augy, Sylvain; Coffin-Pichonnet, Sophie; Mouriaux, Frédéric
2013-12-01
Our aim was to compare the impact of two types of sunglasses on visual field and glare: one ("thick sunglasses") with a thick plastic frame and wide temples and one ("thin sunglasses") with a thin metal frame and thin temples. Using the Goldmann perimeter, visual field surface areas (cm²) were calculated as projections on a 30-cm virtual cupola. A V4 test object was used, from seen to unseen, in 15 healthy volunteers in the primary position of gaze ("base visual field"), then allowing eye motion ("eye motion visual field") without glasses, then with "thin sunglasses," followed by "thick sunglasses." Visual field surface area differences greater than the 14% reproducibility error of the method and having a p < 0.05 were considered significant. A glare test was done using a surgical lighting system pointed at the eye(s) at different incidence angles. No significant "base visual field" or "eye motion visual field" surface area variations were noted when comparing tests done without glasses and with the "thin sunglasses." In contrast, a 22% "eye motion visual field" surface area decrease (p < 0.001) was noted when comparing tests done without glasses and with "thick sunglasses." This decrease was most severe in the temporal quadrant (-33%; p < 0.001). All subjects reported less lateral glare with the "thick sunglasses" than with the "thin sunglasses" (p < 0.001). The better protection from lateral glare offered by "thick sunglasses" is offset by the much poorer ability to use lateral space exploration; this results in a loss of most, if not all, of the additional visual field gained through eye motion.
[Macroeconomic costs of eye diseases].
Hirneiß, C; Kampik, A; Neubauer, A S
2014-05-01
Eye diseases that are relevant regarding their macroeconomic costs and their impact on society include cataract, diabetic retinopathy, age-related maculopathy, glaucoma and refractive errors. The aim of this article is to provide a comprehensive overview of direct and indirect costs for major eye disease categories for Germany, based on existing literature and data sources. A semi-structured literature search was performed in the databases Medline and Embase and in the search machine Google for relevant original papers and reviews on costs of eye diseases with relevance for or transferability to Germany (last research date October 2013). In addition, manual searching was performed in important national databases and information sources, such as the Federal Office of Statistics and scientific societies. The direct costs for these diseases add up to approximately 2.6 billion Euros yearly for the Federal Republic of Germany, including out of the pocket payments from patients but excluding optical aids (e.g. glasses). In addition to those direct costs there are also indirect costs which are caused e.g. by loss of employment or productivity or by a reduction in health-related quality of life. These indirect costs can only be roughly estimated. Including the indirect costs for the eye diseases investigated, a total yearly macroeconomic cost ranging between 4 and 12 billion Euros is estimated for Germany. The costs for the eye diseases cataract, diabetic retinopathy, age-related maculopathy, glaucoma and refractive errors have a macroeconomic relevant dimension. Based on the predicted demographic changes with an ageing society an increase of the prevalence and thus also an increase of costs for eye diseases is expected in the future.
He, Lin; Yang, Hongli; Gardiner, Stuart K.; Williams, Galen; Hardin, Christy; Strouthidis, Nicholas G.; Fortune, Brad; Burgoyne, Claude F.
2014-01-01
Purpose. We determined if the detection of spectral-domain optical coherence tomography (SDOCT) optic nerve head (ONH) change precedes the detection of confocal scanning laser tomography (CSLT) ONH surface, SDOCT retinal nerve fiber layer (RNFL), scanning laser perimetry (SLP), and multifocal electroretinography (mfERG) change in eight experimental glaucoma (EG) eyes. Methods. Both eyes from eight monkeys were tested at least three times at baseline, and then every 2 weeks following laser-induced chronic unilateral IOP elevation. Event and trend-based definitions of onset in the control and EG eyes for 11 SDOCT neural and connective tissue, CSLT surface, SDOCT RNFL, SLP, and mfERG parameters were explored. The frequency and timing of onset for each parameter were compared using a logrank test. Results. Maximum post-laser IOP was 18 to 42 mm Hg in the EG eyes and 12 to 20 mm Hg in the control eyes. For event- and trend-based analyses, onsets were achieved earliest and most frequently within the ONH neural and connective tissues using SDOCT, and at the ONH surface using CSLT. SDOCT ONH neural and connective tissue parameter change preceded or coincided with CSLT ONH surface change in most EG eyes. The SDOCT and SLP measures of RNFL thickness, and mfERG measures of visual function demonstrated similar onset rates, but occurred later than SDOCT ONH and CSLT surface change, and in fewer eyes. Conclusions. SDOCT ONH change detection commonly precedes or coincides with CSLT ONH surface change detection, and consistently precedes RNFLT, SLP, and mfERG change detection in monkey experimental glaucoma. PMID:24255047
NASA Astrophysics Data System (ADS)
Duparré, Jacques; Wippermann, Frank; Dannberg, Peter; Schreiber, Peter; Bräuer, Andreas; Völkel, Reinhard; Scharf, Toralf
2005-09-01
Two novel objective types on the basis of artificial compound eyes are examined. Both imaging systems are well suited for fabrication using microoptics technology due to the small required lens sags. In the apposition optics a microlens array (MLA) and a photo detector array of different pitch in its focal plane are applied. The image reconstruction is based on moire magnification. Several generations of demonstrators of this objective type are manufactured by photo lithographic processes. This includes a system with opaque walls between adjacent channels and an objective which is directly applied onto a CMOS detector array. The cluster eye approach, which is based on a mixture of superposition compound eyes and the vision system of jumping spiders, produces a regular image. Here, three microlens arrays of different pitch form arrays of Keplerian microtelescopes with tilted optical axes, including a field lens. The microlens arrays of this demonstrator are also fabricated using microoptics technology, aperture arrays are applied. Subsequently the lens arrays are stacked to the overall microoptical system on wafer scale. Both fabricated types of artificial compound eye imaging systems are experimentally characterized with respect to resolution, sensitivity and cross talk between adjacent channels. Captured images are presented.
Mannan, Malik M. Naeem; Kim, Shinjung; Jeong, Myung Yung; Kamran, M. Ahmad
2016-01-01
Contamination of eye movement and blink artifacts in Electroencephalogram (EEG) recording makes the analysis of EEG data more difficult and could result in mislead findings. Efficient removal of these artifacts from EEG data is an essential step in improving classification accuracy to develop the brain-computer interface (BCI). In this paper, we proposed an automatic framework based on independent component analysis (ICA) and system identification to identify and remove ocular artifacts from EEG data by using hybrid EEG and eye tracker system. The performance of the proposed algorithm is illustrated using experimental and standard EEG datasets. The proposed algorithm not only removes the ocular artifacts from artifactual zone but also preserves the neuronal activity related EEG signals in non-artifactual zone. The comparison with the two state-of-the-art techniques namely ADJUST based ICA and REGICA reveals the significant improved performance of the proposed algorithm for removing eye movement and blink artifacts from EEG data. Additionally, results demonstrate that the proposed algorithm can achieve lower relative error and higher mutual information values between corrected EEG and artifact-free EEG data. PMID:26907276
A boussinesq model of natural convection in the human eye and the formation of Krukenberg's spindle.
Heys, Jeffrey J; Barocas, Victor H
2002-03-01
The cornea of the human eye is cooled by the surrounding air and by evaporation of the tear film. The temperature difference between the cornea and the iris (at core body temperature) causes circulation of the aqueous humor in the anterior chamber of the eye. Others have suggested that the circulation pattern governs the shape of the Krukenberg spindle, a distinctive vertical band of pigment on the posterior cornea surface in some pathologies. We modeled aqueous humor flow the human eye, treating the humor as a Boussinesq fluid and setting the corneal temperature based on infrared surface temperature measurements. The model predicts convection currents in the anterior chamber with velocities comparable to those resulting from forced flow through the gap between the iris and lens. When paths of pigment particles are calculated based on the predicted flow field, the particles circulate throughout the anterior chamber but tend to be near the vertical centerline of the eye for a greatest period of time. Further, the particles are usually in close proximity to the cornea only when they are near the vertical centerline. We conclude that the convective flow pattern of aqueous humor is consistent with a vertical pigment spindle.
NASA Astrophysics Data System (ADS)
Klein, P.; Viiri, J.; Mozaffari, S.; Dengel, A.; Kuhn, J.
2018-06-01
Relating mathematical concepts to graphical representations is a challenging task for students. In this paper, we introduce two visual strategies to qualitatively interpret the divergence of graphical vector field representations. One strategy is based on the graphical interpretation of partial derivatives, while the other is based on the flux concept. We test the effectiveness of both strategies in an instruction-based eye-tracking study with N =41 physics majors. We found that students' performance improved when both strategies were introduced (74% correct) instead of only one strategy (64% correct), and students performed best when they were free to choose between the two strategies (88% correct). This finding supports the idea of introducing multiple representations of a physical concept to foster student understanding. Relevant eye-tracking measures demonstrate that both strategies imply different visual processing of the vector field plots, therefore reflecting conceptual differences between the strategies. Advanced analysis methods further reveal significant differences in eye movements between the best and worst performing students. For instance, the best students performed predominantly horizontal and vertical saccades, indicating correct interpretation of partial derivatives. They also focused on smaller regions when they balanced positive and negative flux. This mixed-method research leads to new insights into student visual processing of vector field representations, highlights the advantages and limitations of eye-tracking methodologies in this context, and discusses implications for teaching and for future research. The introduction of saccadic direction analysis expands traditional methods, and shows the potential to discover new insights into student understanding and learning difficulties.
Wang, Yu T; Tadarati, Mongkol; Wolfson, Yulia; Bressler, Susan B; Bressler, Neil M
2016-02-01
Diagnosing diabetic macular edema (DME) from monocular fundus photography vs optical coherence tomography (OCT) central subfield thickness (CST) can yield different prevalence rates for DME. Epidemiologic studies and telemedicine screening typically use monocular fundus photography, while treatment of DME uses OCT CST. To compare DME prevalence from monocular fundus photography and OCT. Retrospective cross-sectional study of DME grading based on monocular fundus photographs and OCT images obtained from patients with diabetic retinopathy at a single visit between July 1, 2011, and June 30, 2014, at a university-based practice and analyzed between July 30, 2014, and May 29, 2015. Presence of DME, including clinically significant macular edema (CSME), on monocular fundus photographs used definitions from the Multi-Ethnic Study of Atherosclerosis (MESA) and the National Health and Nutrition Examination Survey (NHANES). Presence of DME on OCT used Diabetic Retinopathy Clinical Research Network eligibility criteria thresholds of CST for trials evaluating anti-vascular endothelial growth factor treatments. Prevalence of DME based on monocular fundus photographs or OCT. A total of 246 eyes of 158 participants (mean [SD] age, 65.0 [11.9] years; 48.7% women; 60.8% white) were included. Among the 246 eyes, the prevalences of DME (61.4%) and CSME (48.5%) based on MESA definitions for monocular fundus photographs were greater than the DME prevalence based on OCT (21.1%) by 40.2% (95% CI, 32.8%-47.7%; P < .001) and 27.2% (95% CI, 19.2%-35.3%; P < .001), respectively. Using NHANES definitions, DME and CSME prevalences from monocular fundus photographs (28.5% and 21.0%, respectively) approximated the DME prevalence from OCT (21.1%). However, among eyes without DME on OCT, 58.2% (95% CI, 51.0%-65.3%) and 18.0% (95% CI, 12.9%-24.2%) were diagnosed as having DME on monocular fundus photographs using MESA and NHANES definitions, respectively, including 47.0% (95% CI, 39.7%-54.5%) and 10.3% (95% CI, 6.3%-15.7%), respectively, with CSME. Among eyes with DME on OCT, 26.9% (95% CI, 15.6%-41.0%) and 32.7% (95% CI, 20.3%-47.1%) were not diagnosed as having either DME or CSME on monocular fundus photographs using MESA and NHANES definitions, respectively. These data suggest that many eyes diagnosed as having DME or CSME on monocular fundus photographs have no DME based on OCT CST, while many eyes diagnosed as not having DME or CSME on monocular fundus photographs have DME on OCT. While limited to 1 clinical practice, caution is suggested when extrapolating prevalence of eyes that may benefit from anti-vascular endothelial growth factor therapy based on epidemiologic surveys using photographs to diagnose DME.
Omar, Artur; Marteinsdottir, Maria; Kadesjö, Nils; Fransson, Annette
2015-06-01
The International Commission on Radiological Protection (ICRP) has recommended that the occupational dose limit to the eye lens be substantially reduced. To ensure compliance with these recommendations, monitoring of the occupational eye lens dose is essential in certain hospital work environments. For assessment of the eye lens dose it is recommended to use a supplementary dosimeter placed at a position adjacent to the eye(s). Wearing a dosimeter at eye level can, however, be impractical and distributing and managing additional dosimeters over long periods of time is cumbersome and costly for large clinical sites. An attractive alternative is to utilize active personal dosimeters (APDs), which are routinely used by clinical staff for real-time monitoring of the personal dose equivalent rate (H(p)(10)). In this work, a formalism for the determination of eye lens dose from the response of such APD's worn on the chest is proposed and evaluated. The evaluation is based on both phantom and clinical measurements performed in an x-ray angiography suite for interventional cardiology. The main results show that the eye lens dose to the primary operator and to the assisting clinical staff can be conservatively estimated from the APD response as D(eye)(conductor) = 2.0 APD chest and D(eye)(assisting) = 1.0 APD chest, respectively. However, care should be exercised for particularly short assisting staff and if radiation protection shields are misused. These concerns can be greatly mitigated if the clinical staff are provided with adequate radiation protection training.
Peak skin and eye lens radiation dose from brain perfusion CT based on Monte Carlo simulation.
Zhang, Di; Cagnon, Chris H; Villablanca, J Pablo; McCollough, Cynthia H; Cody, Dianna D; Stevens, Donna M; Zankl, Maria; Demarco, John J; Turner, Adam C; Khatonabadi, Maryam; McNitt-Gray, Michael F
2012-02-01
The purpose of our study was to accurately estimate the radiation dose to skin and the eye lens from clinical CT brain perfusion studies, investigate how well scanner output (expressed as volume CT dose index [CTDI(vol)]) matches these estimated doses, and investigate the efficacy of eye lens dose reduction techniques. Peak skin dose and eye lens dose were estimated using Monte Carlo simulation methods on a voxelized patient model and 64-MDCT scanners from four major manufacturers. A range of clinical protocols was evaluated. CTDI(vol) for each scanner was obtained from the scanner console. Dose reduction to the eye lens was evaluated for various gantry tilt angles as well as scan locations. Peak skin dose and eye lens dose ranged from 81 mGy to 348 mGy, depending on the scanner and protocol used. Peak skin dose and eye lens dose were observed to be 66-79% and 59-63%, respectively, of the CTDI(vol) values reported by the scanners. The eye lens dose was significantly reduced when the eye lenses were not directly irradiated. CTDI(vol) should not be interpreted as patient dose; this study has shown it to overestimate dose to the skin or eye lens. These results may be used to provide more accurate estimates of actual dose to ensure that protocols are operated safely below thresholds. Tilting the gantry or moving the scanning region further away from the eyes are effective for reducing lens dose in clinical practice. These actions should be considered when they are consistent with the clinical task and patient anatomy.
Carkeet, Andrew; Wood, Joanne M; McNeill, Kylie M; McNeill, Hamish J; James, Joanna A; Holder, Leigh S
The Enright phenomenon describes the distortion in speed perception experienced by an observer looking sideways from a moving vehicle when viewing with interocular differences in retinal image brightness, usually induced by neutral density filters. We investigated whether the Enright phenomenon could be induced with monocular pupil dilation using tropicamide. We tested 17 visually normal young adults on a closed road driving circuit. Participants were asked to travel at Goal Speeds of 40km/h and 60km/h while looking sideways from the vehicle with: (i) both eyes with undilated pupils; (ii) both eyes with dilated pupils; (iii) with the leading eye only dilated; and (iv) the trailing eye only dilated. For each condition we recorded actual driving speed. With the pupil of the leading eye dilated participants drove significantly faster (by an average of 3.8km/h) than with both eyes dilated (p=0.02); with the trailing eye dilated participants drove significantly slower (by an average of 3.2km/h) than with both eyes dilated (p<0.001). The speed, with the leading eye dilated, was faster by an average of 7km/h than with the trailing eye dilated (p<0.001). There was no significant difference between driving speeds when viewing with both eyes either dilated or undilated (p=0.322). Our results are the first to show a measurable change in driving behaviour following monocular pupil dilation and support predictions based on the Enright phenomenon. Copyright © 2016 Spanish General Council of Optometry. Published by Elsevier España, S.L.U. All rights reserved.
Maier, Felix M; Schaeffel, Frank
2013-07-24
To find out whether adaptation to a vertical prism involves more than fusional vertical eye movements. Adaptation to a vertical base-up 3 prism diopter prism was measured in a custom-programmed Maddox test in nine visually normal emmetropic subjects (mean age 27.0 ± 2.8 years). Vertical eye movements were binocularly measured in six of the subjects with a custom-programmed binocular video eye tracker. In the Maddox test, some subjects adjusted the perceived height as expected from the power of the prism while others appeared to ignore the prism. After 15 minutes of adaptation, the interocular difference in perceived height was reduced by on average 51% (from 0.86°-0.44°). The larger the initially perceived difference in height in a subject, the larger the amplitude of adaptation was. Eye tracking showed that the prism generated divergent vertical eye movements of 1.2° on average, which was less than expected from its power. Differences in eye elevation were maintained as long as the prism was in place. Small angles of lateral head tilt generated large interocular differences in eye elevation, much larger than the effects introduced by the prism. Vertical differences in retinal image height were compensated by vertical fusional eye movements but some subjects responded poorly to a vertical prism in both experiments; fusional eye movements were generally too small to realign both foveae with the fixation target; and the prism adaptation in the Maddox test was fully explained by the changes in vertical eye position, suggesting that no further adaptational mechanism may be involved.
Leeungurasatien, Thidarat; Khunsongkiet, Preeyanuch; Pathanapitoon, Kassara; Wiwatwongwana, Damrong
2016-10-01
To determine the incidence of early postoperative complications and associated factors after primary trabeculectomy in Thai glaucoma patients. This was a retrospective observational study performed in Chiang Mai University Hospital. One hundred and eighteen glaucoma patients participated in the study. All glaucoma patients underwent primary trabeculectomy with mitomycin C (MMC) using fornix-based conjunctival flap technique between December 2011 and May 2013. Surgical complications during the first 3 months of follow-up were recorded, and associated risk factors were analyzed. The incidence of posttrabeculectomy complications was the main outcome measure. One hundred and eighteen eyes of 118 patients were included. Early postoperative complications developed in 55 eyes (56.7%). Complications included hypotony (25 eyes, 27.2%), serous choroidal detachment (CD) (14 eyes, 15.6%), subconjunctival hemorrhage (12 eyes, 13.0%), hyphema (11 eyes, 12.4%), bleb leak (8 eyes, 8.8%), encapsulated bleb (2 eyes, 2.2%), aqueous misdirection (1 eyes, 1.1%), corneal epithelial defect (1 eyes, 1.1%), and overfiltration (1 eyes, 1.1%). There were no reported cases of endophthalmitis or blebitis. Hypotony was associated with serous CD (P = 0.006), and hyphema was associated with neovascular glaucoma (NVG) patients (P = 0.009). NVG was not associated with the increased rate of surgical failure (P = 0.083). The incidence of early complications after first-time trabeculectomy with MMC was high (56.7%) in this Thai clinic setting, but most were transient and self-limited conditions. The correlations between hypotony and CD as well as hyphema and NVG were compatible with the previous studies.
Eye Size and Set in Small-Bodied Fossil Primates: A Three-Dimensional Method.
Rosenberger, Alfred L; Smith, Tim D; DeLeon, Valerie B; Burrows, Anne M; Schenck, Robert; Halenar, Lauren B
2016-12-01
We introduce a new method to geometrically reconstruct eye volume and placement in small-bodied primates based on the three-dimensional contour of the intraorbital surface. We validate it using seven species of living primates, with dry skulls and wet dissections, and test its application on seven species of Paleogene fossils of interest. The method performs well even when the orbit is damaged and incomplete, lacking the postorbital bar and represented only by the orbital floor. Eye volume is an important quantity for anatomic and metabolic reasons, which due to differences in eye set, or position within (or outside) the bony orbit, can be underestimated in living and fossil forms when calculated from aperture diameter. Our Ectopic Index quantifies how much the globe's volume protrudes anteriorly from the aperture. Lemur, Notharctus and Rooneyia resemble anthropoids, with deeply recessed eyes protruding 11%-13%. Galago and Tarsius are the other extreme, at 47%-56%. We argue that a laterally oriented aperture has little to do with line-of-sight in euprimates, as large ectopic eyes can position the cornea to enable a directly forward viewing axis, and soft tissue positions the eyes facing forward in megachiropteran bats, which have unenclosed, open eye sockets. The size and set of virtual eyes reconstructed from 3D cranial models confirm that eyes were large to hypertrophic in Hemiacodon, Necrolemur, Microchoerus, Pseudoloris and Shoshonius, but eye size in Rooneyia may have been underestimated by measuring the aperture, as in Aotus. Anat Rec, 299:1671-1689, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Grating visual acuity results in the early treatment for retinopathy of prematurity study.
Dobson, Velma; Quinn, Graham E; Summers, C Gail; Hardy, Robert J; Tung, Betty; Good, William V
2011-07-01
To compare grating (resolution) visual acuity at 6 years of age in eyes that received early treatment (ET) for high-risk prethreshold retinopathy of prematurity (ROP) with that in eyes that underwent conventional management (CM). In a randomized clinical trial, infants with bilateral, high-risk prethreshold ROP (n = 317) had one eye undergo ET and the other eye undergo CM, with treatment only if ROP progressed to threshold severity. For asymmetric cases (n = 84), the high-risk prethreshold eye was randomized to ET or CM. Grating visual acuity measured at 6 years of age by masked testers using Teller acuity cards. Monocular grating acuity results were obtained from 317 of 370 surviving children (85.6%). Analysis of grating acuity results for all study participants with high-risk prethreshold ROP showed no statistically significant overall benefit of ET (18.1% vs 22.8% unfavorable outcomes; P = .08). When the 6-year grating acuity results were analyzed according to a clinical algorithm (high-risk types 1 and 2 prethreshold ROP), a benefit was seen in type 1 eyes (16.4% vs 25.2%; P = .004) undergoing ET, but not in type 2 eyes (21.3% vs 15.9%; P = .29). Early treatment of eyes with type 1 ROP improves grating acuity outcomes, but ET for eyes with type 2 ROP does not. APPLICATION TO CLINICAL MEDICINE: Type 1 eyes should be treated early; however, based on acuity results at 6 years of age, type 2 eyes should be cautiously monitored for progression to type 1 ROP. Trial Registration clinicaltrials.gov Identifier: NCT00027222.
Robotic laser tissue welding of sclera using chitosan films.
Garcia, Pablo; Mines, Michael J; Bower, Kraig S; Hill, J; Menon, J; Tremblay, Eric; Smith, Benjamin
2009-01-01
To demonstrate the feasibility of scleral wound closure using a novel adhesive made of chitosan film. Five-millimeter scleral lacerations were created in enucleated pig eyes. Casted chitosan films were sized to 7x7 mm patches. Lacerations were sealed with chitosan film alone (7 eyes) or chitosan film followed by laser irradiation using a near infrared laser (1,455 nm) at 350 mW for 6 minutes (7 eyes). Seven eyes were closed with 9-0 nylon suture for comparison (7 eyes). Outcome measures included watertight closure, closure time, and leak pressure. Leak pressure was measured with a pressure transducer attached to tubing continuously monitored intraocular pressure during saline infusion. Watertight closure testing was performed immediately following closure (n = 3 per group) and after 24 hours (n = 3 per group). One eye in each group was fixed in formalin for histology. All wounds were watertight for each closure method. Mean closure time with unlasered chitosan film was 2.24 minutes (range 1.80-3.26, 7 eyes) with a mean leak pressure of 303 mm Hg (range 217-364, 3 eyes). Mean closure time with lasered chitosan was 12.47 minutes (range 11.45-14.15, 7 eyes) with a mean leak pressure of 454.7 mm Hg (range 152-721, 3 eyes). Suture closure required a mean of 4.83 minutes (range 4.03-7.30, 7 eyes) and resulted in a mean leak pressure of 570.3 mm Hg (range 460-646, 3 eyes). Both lasered and unlasered chitosan eyes remained watertight after 24 hours. Histology revealed minimal laser tissue damage in lasered eyes. In this preliminary study chitosan film successfully closed scleral lacerations with and without the application of laser energy. While laser appears to strengthen the closure, it significantly increases the closure time. Chitosan based adhesives hold promise as a scleral wound closure technique.
Photorefractive keratectomy in the correction of astigmatism using Schwind Amaris 750s laser
Baz, Okkes; Kara, Necip; Bozkurt, Ercument; Ozgurhan, Engin Bilge; Agca, Alper; Yuksel, Kemal; Ozpinar, Yavuz; Demirok, Ahmet
2013-01-01
AIM To evaluate the results of three photorefractive keratectomy (PRK) procedures in the treatment of astigmatism. METHODS In this retrospective comparative case series, 89 eyes of 50 patients who underwent PRK treatment for astigmatism were enrolled. The patients were divided into 3 groups based on the PRK procedure: Group 1: PRK without mitomycin-C (MMC) application, Group 2: PRK with MMC application, and Group 3: Trans-Photorefractive Keratectomy (T-PRK). The efficacy, safety, predictability, and complications of treatment were assessed at 1, 3 and 6 months after the treatment. RESULTS At postoperative 6 months, the percentage of postoperative uncorrected visual acuity (UCVA) of 20/20 or better was 55.6% (20 eyes) in group 1, 75% (15 eyes) in group 2, and 75.8% (25 eyes) in group 3 (P=0.144). The percentage of postoperative best corrected visual acuity (BCVA) of unchanged or gained ≥1 lines was 80.6% (29 eyes) in group 1, 70% (14 eyes) in group 2, and 90.9% (30 eyes) in group 3 (P=0.151). The percentage of postoperative BCVA of lost ≥2 lines was 11.1% (4 eyes) in group 1, 20% (4 eyes) in group 2, and 6.1% (2 eyes) in group 3. The mean manifest refractive spherical equivalent (MRSE) and mean cylindrical refraction were not significantly different among the each groups (P>0.05). At postoperative 6 months, the percentage of MRSE of within ±0.50 D was 100% (36 eyes) in Group 1, 100% (20 eyes) in Group 2, and 93.9% (31 eyes) in Group 3. At the each follow-up period, there was no significant difference in number of eyes with haze and mean haze score(P>0.05). CONCLUSION The study showed that PRK without MMC, PRK with MMC and T-PRK appears to have similar effectiveness, safety and predictability in the treatment of astigmatism. The incidence of haze was also similar between the three groups. PMID:23826533
The Rate of Visual Field Change in the Ocular Hypertension Treatment Study
De Moraes, Carlos Gustavo V.; Gardiner, Stuart K.; Liebmann, Jeffrey M.; Cioffi, George A.; Ritch, Robert; Gordon, Mae O.; Kass, Michael A.
2012-01-01
Purpose. To assess the rate of change of visual field (VF) mean deviation (MD) in the Ocular Hypertension Treatment Study (OHTS). Methods. OHTS data were filtered to exclude eyes that had fewer than 10 reliable VFs or less than 5 years of follow-up or that reached a nonglaucomatous endpoint. The rate of change of MD (MDR) was calculated for each eye. Differences were sought between groups of eyes differing in primary open angle glaucoma (POAG) outcome, how POAG was determined, and original randomization. Results. In total, 2609 eyes (1379 participants) met the selection criteria. The mean MDR was −0.08 ± 0.20 dB/y (±SD). POAG eyes (n = 359) had significantly worse MDRs (−0.26 ± 0.36 dB/y) than non-POAG eyes (n = 2250; −0.05 ± 0.14 dB/y; P < 0.001). Eyes that reached POAG endpoints based on only VF change (n = 74; −0.29 ± 0.31 dB/y) or only optic disc change (n = 158; −0.12 ± 0.19 dB/y) had significantly worse MDRs than non-POAG eyes (both P < 0.001). Eyes that reached POAG endpoints for both VF and optic disc change (n = 127) deteriorated more rapidly (−0.42 ± 0.46 dB/y) than eyes showing only VF change (P = 0.017) or only optic disc change (P < 0.001). There was not a significant association between MDR and original OHTS randomization (observe vs. treat, P = 0.168). Conclusions. Eyes that develop POAG have significantly worse MDRs than eyes that do not. Eyes that reached endpoints due to both VF and optic disc change had worse MDRs than eyes displaying change in only one of these. MDR was not significantly associated with randomization, suggesting that MDR may not be the best measure of VF change in early-stage POAG. (ClinicalTrials.gov number, NCT00000125.) PMID:22159015
Antic, V; Ciraj-Bjelac, O; Rehani, M; Aleksandric, S; Arandjic, D; Ostojic, M
2013-01-01
Workers involved in interventional cardiology procedures receive high eye lens dose if protection is not used. Currently, there is no suitable method for routine use for the measurement of eye dose. Since most angiography machines are equipped with suitable patient dosemeters, deriving factors linking staff eye doses to the patient doses can be helpful. In this study the patient kerma-area product, cumulative dose at an interventional reference point and eye dose in terms of Hp(3) of the cardiologists, nurses and radiographers for interventional cardiology procedures have been measured. Correlations between the patient dose and the staff eye dose were obtained. The mean eye dose was 121 µSv for the first operator, 33 µSv for the second operator/nurse and 12 µSv for radiographer. Normalised eye lens doses per unit kerma-area product were 0.94 µSv Gy⁻¹ cm⁻² for the first operator, 0.33 µSv Gy⁻¹ cm⁻² for the second operator/nurse and 0.16 µSv Gy⁻¹ cm⁻² for radiographers. Statistical analysis indicated that there is a weak but significant (p < 0.01) correlation between the eye dose and the kerma-area product for all three staff categories. These values are based on a local practice and may provide useful reference for other studies for validation and for wider utilisation in assessing the eye dose using patient dose values.
An ocular biomechanic model for dynamic simulation of different eye movements.
Iskander, J; Hossny, M; Nahavandi, S; Del Porto, L
2018-04-11
Simulating and analysing eye movement is useful for assessing visual system contribution to discomfort with respect to body movements, especially in virtual environments where simulation sickness might occur. It can also be used in the design of eye prosthesis or humanoid robot eye. In this paper, we present two biomechanic ocular models that are easily integrated into the available musculoskeletal models. The model was previously used to simulate eye-head coordination. The models are used to simulate and analyse eye movements. The proposed models are based on physiological and kinematic properties of the human eye. They incorporate an eye-globe, orbital suspension tissues and six muscles with their connective tissues (pulleys). Pulleys were incorporated in rectus and inferior oblique muscles. The two proposed models are the passive pulleys and the active pulleys models. Dynamic simulations of different eye movements, including fixation, saccade and smooth pursuit, are performed to validate both models. The resultant force-length curves of the models were similar to the experimental data. The simulation results show that the proposed models are suitable to generate eye movement simulations with results comparable to other musculoskeletal models. The maximum kinematic root mean square error (RMSE) is 5.68° and 4.35° for the passive and active pulley models, respectively. The analysis of the muscle forces showed realistic muscle activation with increased muscle synergy in the active pulley model. Copyright © 2018 Elsevier Ltd. All rights reserved.
Bayesian microsaccade detection
Mihali, Andra; van Opheusden, Bas; Ma, Wei Ji
2017-01-01
Microsaccades are high-velocity fixational eye movements, with special roles in perception and cognition. The default microsaccade detection method is to determine when the smoothed eye velocity exceeds a threshold. We have developed a new method, Bayesian microsaccade detection (BMD), which performs inference based on a simple statistical model of eye positions. In this model, a hidden state variable changes between drift and microsaccade states at random times. The eye position is a biased random walk with different velocity distributions for each state. BMD generates samples from the posterior probability distribution over the eye state time series given the eye position time series. Applied to simulated data, BMD recovers the “true” microsaccades with fewer errors than alternative algorithms, especially at high noise. Applied to EyeLink eye tracker data, BMD detects almost all the microsaccades detected by the default method, but also apparent microsaccades embedded in high noise—although these can also be interpreted as false positives. Next we apply the algorithms to data collected with a Dual Purkinje Image eye tracker, whose higher precision justifies defining the inferred microsaccades as ground truth. When we add artificial measurement noise, the inferences of all algorithms degrade; however, at noise levels comparable to EyeLink data, BMD recovers the “true” microsaccades with 54% fewer errors than the default algorithm. Though unsuitable for online detection, BMD has other advantages: It returns probabilities rather than binary judgments, and it can be straightforwardly adapted as the generative model is refined. We make our algorithm available as a software package. PMID:28114483
Tear dynamics in healthy and dry eyes.
Cerretani, Colin F; Radke, C J
2014-06-01
Dry-eye disease, an increasingly prevalent ocular-surface disorder, significantly alters tear physiology. Understanding the basic physics of tear dynamics in healthy and dry eyes benefits both diagnosis and treatment of dry eye. We present a physiological-based model to describe tear dynamics during blinking. Tears are compartmentalized over the ocular surface; the blink cycle is divided into three repeating phases. Conservation laws quantify the tear volume and tear osmolarity of each compartment during each blink phase. Lacrimal-supply and tear-evaporation rates are varied to reveal the dependence of tear dynamics on dry-eye conditions, specifically tear osmolarity, tear volume, tear-turnover rate (TTR), and osmotic water flow. Predicted periodic-steady tear-meniscus osmolarity is 309 and 321 mOsM in normal and dry eyes, respectively. Tear osmolarity, volume, and TTR all match available clinical measurements. Osmotic water flow through the cornea and conjunctiva contribute 10 and 50% to the total tear supply in healthy and dry-eye conditions, respectively. TTR in aqueous-deficient dry eye (ADDE) is only half that in evaporative dry eye (EDE). The compartmental periodic-steady tear-dynamics model accurately predicts tear behavior in normal and dry eyes. Inclusion of osmotic water flow is crucial to match measured tear osmolarity. Tear-dynamics predictions corroborate the use of TTR as a clinical discriminator between ADDE and EDE. The proposed model is readily extended to predict the dynamics of aqueous solutes such as drugs or fluorescent tags.
Zhou, Ling Xiao; Shao, Lei; Xu, Liang; Wei, Wen Bin; Wang, Ya Xing; You, Qi Sheng
2017-08-29
Based on the Beijing Eye Study 2011, a detailed ophthalmic examination was performed including spectral-domain optical coherence tomography (SD-OCT) with enhanced depth imaging for measurement of subfoveal choroidal thickness (SFCT) and relative height of posterior scleral staphyloma. OCT images were obtained in 103 highly myopic eyes (≤-6.00 diopters) and 227 normal eyes. The mean SFCT in highly myopic eyes was 110.6 ± 85.2 μm (range, 3 to 395 μm). The SFCT of high myopia without posterior scleral staphyloma(55 eyes) was 157.79 ± 85.18 μm, which was significantly greater than that (54.94 ± 49.96 μm) of high myopia with posterior scleral staphyloma (48 eyes) (P < 0.001). In multivariate analysis, posterior scleral staphyloma was the most important factor of choroidal thinning in high myopia (F = 22.63; P < 0.001), then age (F = 19.14; P < 0.001), axial length (F = 17.37; P < 0.001) and gender (F = 17.31; P < 0.001). The SFCT in highly myopic eyes is very thin and undergoes further thinning with increasing age and axial length (refractive error). Posterior staphyloma formation was a key factor in choroidal thinning in highly myopic eyes and to be a good indicator for risk management of choroidal thinning. Abnormalities of the choroid may play a role in the pathogenesis of myopic degeneration.
Shin, Jaeyoung; Müller, Klaus-R; Hwang, Han-Jeong
2016-01-01
We propose a near-infrared spectroscopy (NIRS)-based brain-computer interface (BCI) that can be operated in eyes-closed (EC) state. To evaluate the feasibility of NIRS-based EC BCIs, we compared the performance of an eye-open (EO) BCI paradigm and an EC BCI paradigm with respect to hemodynamic response and classification accuracy. To this end, subjects performed either mental arithmetic or imagined vocalization of the English alphabet as a baseline task with very low cognitive loading. The performances of two linear classifiers were compared; resulting in an advantage of shrinkage linear discriminant analysis (LDA). The classification accuracy of EC paradigm (75.6 ± 7.3%) was observed to be lower than that of EO paradigm (77.0 ± 9.2%), which was statistically insignificant (p = 0.5698). Subjects reported they felt it more comfortable (p = 0.057) and easier (p < 0.05) to perform the EC BCI tasks. The different task difficulty may become a cause of the slightly lower classification accuracy of EC data. From the analysis results, we could confirm the feasibility of NIRS-based EC BCIs, which can be a BCI option that may ultimately be of use for patients who cannot keep their eyes open consistently. PMID:27824089
Shin, Jaeyoung; Müller, Klaus-R; Hwang, Han-Jeong
2016-11-08
We propose a near-infrared spectroscopy (NIRS)-based brain-computer interface (BCI) that can be operated in eyes-closed (EC) state. To evaluate the feasibility of NIRS-based EC BCIs, we compared the performance of an eye-open (EO) BCI paradigm and an EC BCI paradigm with respect to hemodynamic response and classification accuracy. To this end, subjects performed either mental arithmetic or imagined vocalization of the English alphabet as a baseline task with very low cognitive loading. The performances of two linear classifiers were compared; resulting in an advantage of shrinkage linear discriminant analysis (LDA). The classification accuracy of EC paradigm (75.6 ± 7.3%) was observed to be lower than that of EO paradigm (77.0 ± 9.2%), which was statistically insignificant (p = 0.5698). Subjects reported they felt it more comfortable (p = 0.057) and easier (p < 0.05) to perform the EC BCI tasks. The different task difficulty may become a cause of the slightly lower classification accuracy of EC data. From the analysis results, we could confirm the feasibility of NIRS-based EC BCIs, which can be a BCI option that may ultimately be of use for patients who cannot keep their eyes open consistently.
König, C D
1983-07-01
In a comparative study the clinical efficacy of five different treatments of keratoconjunctivitis infectiosa ovis (KIO) were tested, namely an intramuscular injection of chloramphenicol base (dosage 15 mg/kg), spiramycin base (Suanovil dosages 10 to 25 mg/kg), oxytetracycline (Engemycine Forte, Terramycin LA, dosages respectively 5 and 10 mg/kg), tiamulin (Dynamutulin, dosage 10 mg/kg) and subcutaneous injection of procaine penicillin G, benzathine penicillin G. and dihydrostreptomycin in the lower eyelid. It appeared from these field trials that spiramycin base, oxytetracycline and tiamulin had a clearly positive effect on the clinical course of 'pink eye', although with tiamulin there was only a temporary effect (high percentage of relapses). In view of the field data the following dosage schemes are, for the time being, advised: spiramycin base (Suanovil), and oxytetracycline (formulation with a good biological availability) both 20 to 30 mg/kg and, if necessary, to be repeated on days 5 and 10 after the first intramuscular injection. The dosage scheme advised for tiamulin is 20-30 mg/kg to be repeated on day 3 and if necessary on days 6 and 9 after the intramuscular injection. In mild cases it is sufficient to rub the eyes with for example oxytetracycline eye-ointment, a few times a day.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kang, Sei-Kwon; Yoon, Jai-Woong; Hwang, Taejin
A metallic contact eye shield has sometimes been used for eyelid treatment, but dose distribution has never been reported for a patient case. This study aimed to show the shield-incorporated CT-based dose distribution using the Pinnacle system and Monte Carlo (MC) calculation for 3 patient cases. For the artifact-free CT scan, an acrylic shield machined as the same size as that of the tungsten shield was used. For the MC calculation, BEAMnrc and DOSXYZnrc were used for the 6-MeV electron beam of the Varian 21EX, in which information for the tungsten, stainless steel, and aluminum material for the eye shieldmore » was used. The same plan was generated on the Pinnacle system and both were compared. The use of the acrylic shield produced clear CT images, enabling delineation of the regions of interest, and yielded CT-based dose calculation for the metallic shield. Both the MC and the Pinnacle systems showed a similar dose distribution downstream of the eye shield, reflecting the blocking effect of the metallic eye shield. The major difference between the MC and the Pinnacle results was the target eyelid dose upstream of the shield such that the Pinnacle system underestimated the dose by 19 to 28% and 11 to 18% for the maximum and the mean doses, respectively. The pattern of dose difference between the MC and the Pinnacle systems was similar to that in the previous phantom study. In conclusion, the metallic eye shield was successfully incorporated into the CT-based planning, and the accurate dose calculation requires MC simulation.« less
Manna, Soumyarwit; Banerjee, Rupak K; Augsburger, James J; Al-Rjoub, Marwan F; Donnell, Anna; Correa, Zelia M
2015-08-01
The purpose of this study was to evaluate the pharmacokinetics and toxicity of a chitosan (CS) and polylactic acid (PLA) based methotrexate (MTX) intravitreal micro-implant in an animal model using rabbit eyes. CS- and PLA-based micro-implants containing 400 μg of MTX were fabricated using lyophilization and dip-coating techniques. The micro-implants were surgically implanted in the vitreous of eight New Zealand rabbits employing minimally invasive technique. The PLA-coated CS-MTX micro-implant was inserted in the right eye and the placebo micro-implant in the left eye of each rabbit. Two rabbits were euthanized at each pre-determined time point post-implantation (days 5, 12, 19, and 33) for pharmacokinetics and histopathology evaluation. A therapeutic concentration of MTX (0.1-1.0 μM) in the vitreous was detected in the rabbit eyes studied for 33 days. The MTX release from the coated micro-implants followed a first order kinetics (R (2) ~ 0.88), implying that MTX release depends on the concentration of MTX in the micro-implant. Histopathological analysis of the enucleated eyes failed to show any signs of infection or tissue toxicity in any of the specimens. The PLA-coated CS-MTX micro-implants were able to deliver therapeutic release of MTX for a period of more than 1 month without detectable toxicity in a rabbit model. The micro-implants can be further investigated as a prospective alternative to current treatment protocols of repeated intravitreal MTX injections in intraocular disorders such as primary intraocular lymphoma, and selected cases of non-microbial intraocular inflammation.
Boivin, Michael J; Weiss, Jonathan; Chhaya, Ronak; Seffren, Victoria; Awadu, Jorem; Sikorskii, Alla; Giordani, Bruno
2017-07-01
Tobii eye tracking was compared with webcam-based observer scoring on an animation viewing measure of attention (Early Childhood Vigilance Test; ECVT) to evaluate the feasibility of automating measurement and scoring. Outcomes from both scoring approaches were compared with the Mullen Scales of Early Learning (MSEL), Color-Object Association Test (COAT), and Behavior Rating Inventory of Executive Function for preschool children (BRIEF-P). A total of 44 children 44 to 65 months of age were evaluated with the ECVT, COAT, MSEL, and BRIEF-P. Tobii ×2-30 portable infrared cameras were programmed to monitor pupil direction during the ECVT 6-min animation and compared with observer-based PROCODER webcam scoring. Children watched 78% of the cartoon (Tobii) compared with 67% (webcam scoring), although the 2 measures were highly correlated (r = .90, p = .001). It is possible for 2 such measures to be highly correlated even if one is consistently higher than the other (Bergemann et al., 2012). Both ECVT Tobii and webcam ECVT measures significantly correlated with COAT immediate recall (r = .37, p = .02 vs. r = .38, p = .01, respectively) and total recall (r = .33, p = .06 vs. r = .42, p = .005) measures. However, neither the Tobii eye tracking nor PROCODER webcam ECVT measures of attention correlated with MSEL composite cognitive performance or BRIEF-P global executive composite. ECVT scoring using Tobii eye tracking is feasible with at-risk very young African children and consistent with webcam-based scoring approaches in their correspondence to one another and other neurocognitive performance-based measures. By automating measurement and scoring, eye tracking technologies can improve the efficiency and help better standardize ECVT testing of attention in younger children. This holds promise for other neurodevelopmental tests where eye movements, tracking, and gaze length can provide important behavioral markers of neuropsychological and neurodevelopmental processes associated with such tests. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Speiser, Daniel I; Gagnon, Yakir Luc; Chhetri, Raghav K; Oldenburg, Amy L; Johnsen, Sönke
2016-11-01
The eyes of scallops form images using a concave spherical mirror and contain two separate retinas, one layered on top of the other. Behavioral and electrophysiological studies indicate that the images formed by these eyes have angular resolutions of about 2°. Based on previous ray-tracing models, it has been thought that the more distal of the two retinas lies near the focal point of the mirror and that the proximal retina, positioned closer to the mirror at the back of the eye, receives light that is out-of-focus. Here, we propose three mechanisms through which both retinas may receive focused light: (1) chromatic aberration produced by the lens may cause the focal points for longer and shorter wavelengths to fall near the distal and proximal retinas, respectively; (2) focused light from near and far objects may fall on the distal and proximal retinas, respectively; and (3) the eyes of scallops may be dynamic structures that change shape to determine which retina receives focused light. To test our hypotheses, we used optical coherence tomography (OCT), a method of near-infrared optical depth-ranging, to acquire virtual cross-sections of live, intact eyes from the bay scallop Argopecten irradians Next, we used a custom-built ray-tracing model to estimate the qualities of the images that fall on an eye's distal and proximal retinas as functions of the wavelengths of light entering the eye (400-700 nm), object distances (0.01-1 m), and the overall shape of the eye. When we assume 550 nm wavelength light and object distances greater than 0.01 m, our model predicts that the angular resolutions of the distal and proximal retinas are 2° and 7°, respectively. Our model also predicts that neither chromatic aberration nor differences in object distance lead to focused light falling on the distal and proximal retinas simultaneously. However, if scallops can manipulate the shapes of their eyes, perhaps through muscle contractions, we speculate that they may be able to influence the qualities of the images that fall on their proximal retinas and-to a lesser extent-those that fall on their distal retinas as well. © The Author 2016. Published by Oxford University Press on behalf of the Society for Integrative and Comparative Biology.
Owsley, Cynthia; Rhodes, Lindsay A; McGwin, Gerald; Mennemeyer, Stephen T; Bregantini, Mary; Patel, Nita; Wiley, Demond M; LaRussa, Frank; Box, Dan; Saaddine, Jinan; Crews, John E; Girkin, Christopher A
2015-11-18
Primary open angle glaucoma is a chronic, progressive eye disease that is the leading cause of blindness among African Americans. Glaucoma progresses more rapidly and appears about 10 years earlier in African Americans as compared to whites. African Americans are also less likely to receive comprehensive eye care when glaucoma could be detected before irreversible blindness. Screening and follow-up protocols for managing glaucoma recommended by eye-care professional organizations are often not followed by primary eye-care providers, both ophthalmologists and optometrists. There is a pressing need to improve both the accessibility and quality of glaucoma care for African Americans. Telemedicine may be an effective solution for improving management and diagnosis of glaucoma because it depends on ocular imaging and tests that can be electronically transmitted to remote reading centers where tertiary care specialists can examine the results. We describe the Eye Care Quality and Accessibility Improvement in the Community project (EQUALITY), set to evaluate a teleglaucoma program deployed in retail-based primary eye care practices serving communities with a large percentage of African Americans. We conducted an observational, 1-year prospective study based in two Walmart Vision Centers in Alabama staffed by primary care optometrists. EQUALITY focuses on new or existing adult patients who are at-risk for glaucoma or already diagnosed with glaucoma. Patients receive dilated comprehensive examinations and diagnostic testing for glaucoma, followed by the optometrist's diagnosis and a preliminary management plan. Results are transmitted to a glaucoma reading center where ophthalmologists who completed fellowship training in glaucoma review results and provide feedback to the optometrist, who manages the care of the patient. Patients also receive eye health education about glaucoma and comprehensive eye care. Research questions include diagnostic and management agreement between providers, the impact of eye health education on patients' knowledge and adherence to follow-up and medication, patient satisfaction, program cost-effectiveness, and EQUALITY's impact on Walmart pharmacy prescription rates. As eye-care delivery systems in the US strive to improve quality while reducing costs, telemedicine programs including teleglaucoma initiatives such as EQUALITY could contribute toward reaching this goal, particularly among underserved populations at-risk for chronic blinding diseases.
Web Camera Based Eye Tracking to Assess Visual Memory on a Visual Paired Comparison Task.
Bott, Nicholas T; Lange, Alex; Rentz, Dorene; Buffalo, Elizabeth; Clopton, Paul; Zola, Stuart
2017-01-01
Background: Web cameras are increasingly part of the standard hardware of most smart devices. Eye movements can often provide a noninvasive "window on the brain," and the recording of eye movements using web cameras is a burgeoning area of research. Objective: This study investigated a novel methodology for administering a visual paired comparison (VPC) decisional task using a web camera.To further assess this method, we examined the correlation between a standard eye-tracking camera automated scoring procedure [obtaining images at 60 frames per second (FPS)] and a manually scored procedure using a built-in laptop web camera (obtaining images at 3 FPS). Methods: This was an observational study of 54 clinically normal older adults.Subjects completed three in-clinic visits with simultaneous recording of eye movements on a VPC decision task by a standard eye tracker camera and a built-in laptop-based web camera. Inter-rater reliability was analyzed using Siegel and Castellan's kappa formula. Pearson correlations were used to investigate the correlation between VPC performance using a standard eye tracker camera and a built-in web camera. Results: Strong associations were observed on VPC mean novelty preference score between the 60 FPS eye tracker and 3 FPS built-in web camera at each of the three visits ( r = 0.88-0.92). Inter-rater agreement of web camera scoring at each time point was high (κ = 0.81-0.88). There were strong relationships on VPC mean novelty preference score between 10, 5, and 3 FPS training sets ( r = 0.88-0.94). Significantly fewer data quality issues were encountered using the built-in web camera. Conclusions: Human scoring of a VPC decisional task using a built-in laptop web camera correlated strongly with automated scoring of the same task using a standard high frame rate eye tracker camera.While this method is not suitable for eye tracking paradigms requiring the collection and analysis of fine-grained metrics, such as fixation points, built-in web cameras are a standard feature of most smart devices (e.g., laptops, tablets, smart phones) and can be effectively employed to track eye movements on decisional tasks with high accuracy and minimal cost.
Matsumoto, Akihiro; Tachibana, Masao
2017-01-01
Even when the body is stationary, the whole retinal image is always in motion by fixational eye movements and saccades that move the eye between fixation points. Accumulating evidence indicates that the brain is equipped with specific mechanisms for compensating for the global motion induced by these eye movements. However, it is not yet fully understood how the retina processes global motion images during eye movements. Here we show that global motion images evoke novel coordinated firing in retinal ganglion cells (GCs). We simultaneously recorded the firing of GCs in the goldfish isolated retina using a multi-electrode array, and classified each GC based on the temporal profile of its receptive field (RF). A moving target that accompanied the global motion (simulating a saccade following a period of fixational eye movements) modulated the RF properties and evoked synchronized and correlated firing among local clusters of the specific GCs. Our findings provide a novel concept for retinal information processing during eye movements.
Eye Tracking Based Control System for Natural Human-Computer Interaction
Lin, Shu-Fan
2017-01-01
Eye movement can be regarded as a pivotal real-time input medium for human-computer communication, which is especially important for people with physical disability. In order to improve the reliability, mobility, and usability of eye tracking technique in user-computer dialogue, a novel eye control system with integrating both mouse and keyboard functions is proposed in this paper. The proposed system focuses on providing a simple and convenient interactive mode by only using user's eye. The usage flow of the proposed system is designed to perfectly follow human natural habits. Additionally, a magnifier module is proposed to allow the accurate operation. In the experiment, two interactive tasks with different difficulty (searching article and browsing multimedia web) were done to compare the proposed eye control tool with an existing system. The Technology Acceptance Model (TAM) measures are used to evaluate the perceived effectiveness of our system. It is demonstrated that the proposed system is very effective with regard to usability and interface design. PMID:29403528
Morone, Piergiuseppe; Camacho Cuena, Eva; Kocur, Ivo; Banatvala, Nicholas
2014-05-01
This article empirically evaluates advocacy in low- and middle-income countries as a key tool for raising policy priority and securing high-level decision maker support in eye health. We used a unique data set based on a survey conducted by World Health Organization in 2011 on eye care and prevention of blindness in 82 low- and middle-income countries. The theoretical framework derives from the idea that a plethora of stakeholders at local and global level pressure national governments, acting in economic and the political spheres. Previously, eye care has not been investigated in such a framework. We found structural differences across countries with different income levels and proposed policy recommendations to secure high-level decision makers' support for promoting eye health. Three case studies suggest that, in order to secure more support and resources for eye health, domestic and international stakeholders must strengthen their engagement with ministries of health at political and above all economic levels.
Eye Tracking Based Control System for Natural Human-Computer Interaction.
Zhang, Xuebai; Liu, Xiaolong; Yuan, Shyan-Ming; Lin, Shu-Fan
2017-01-01
Eye movement can be regarded as a pivotal real-time input medium for human-computer communication, which is especially important for people with physical disability. In order to improve the reliability, mobility, and usability of eye tracking technique in user-computer dialogue, a novel eye control system with integrating both mouse and keyboard functions is proposed in this paper. The proposed system focuses on providing a simple and convenient interactive mode by only using user's eye. The usage flow of the proposed system is designed to perfectly follow human natural habits. Additionally, a magnifier module is proposed to allow the accurate operation. In the experiment, two interactive tasks with different difficulty (searching article and browsing multimedia web) were done to compare the proposed eye control tool with an existing system. The Technology Acceptance Model (TAM) measures are used to evaluate the perceived effectiveness of our system. It is demonstrated that the proposed system is very effective with regard to usability and interface design.
Qureshi, Babar M; Mansur, Rabiu; Al-Rajhi, Abdulaziz; Lansingh, Van; Eckert, Kristen; Hassan, Kunle; Ravilla, Thulasiraj; Muhit, Mohammad; Khanna, Rohit C; Ismat, Chaudhry
2012-01-01
Since the launching of Global Initiative, VISION 2020 “the Right to Sight” many innovative, practical and unique comprehensive eye care services provision models have evolved targeting the underserved populations in different parts of the World. At places the rapid assessment of the burden of eye diseases in confined areas or utilizing the key informants for identification of eye diseases in the communities are promoted for better planning and evidence based advocacy for getting / allocation of resources for eye care. Similarly for detection and management of diabetes related blindness, retinopathy of prematurity and avoidable blindness at primary level, the major obstacles are confronted in reaching to them in a cost effective manner and then management of the identified patients accordingly. In this regard, the concept of tele-ophthalmology model sounds to be the best solution. Whereas other models on comprehensive eye care services provision have been emphasizing on surgical output through innovative scales of economy that generate income for the program and ensure its sustainability, while guaranteeing treatment of the poorest of the poor. PMID:22944741
A Chronic Autoimmune Dry Eye Rat Model with Increase in Effector Memory T Cells in Eyeball Tissue.
Hou, Aihua; Bose, Tanima; Chandy, K George; Tong, Louis
2017-06-07
Dry eye disease is a very common condition that causes morbidity and healthcare burden and decreases the quality of life. There is a need for a suitable dry eye animal model to test novel therapeutics to treat autoimmune dry eye conditions. This protocol describes a chronic autoimmune dry eye rat model. Lewis rats were immunized with an emulsion containing lacrimal gland extract, ovalbumin, and complete Freund's adjuvant. A second immunization with the same antigens in incomplete Freund's adjuvant was administered two weeks later. These immunizations were administered subcutaneously at the base of the tail. To boost the immune response at the ocular surface and lacrimal glands, lacrimal gland extract and ovalbumin were injected into the forniceal subconjunctiva and lacrimal glands 6 weeks after the first immunization. The rats developed dry eye features, including reduced tear production, decreased tear stability, and increased corneal damage. Immune profiling by flow cytometry showed a preponderance of CD3 + effector memory T cells in the eyeball.
A Chronic Autoimmune Dry Eye Rat Model with Increase in Effector Memory T Cells in Eyeball Tissue
Hou, Aihua; Bose, Tanima; Chandy, K. George; Tong, Louis
2017-01-01
Dry eye disease is a very common condition that causes morbidity and healthcare burden and decreases the quality of life. There is a need for a suitable dry eye animal model to test novel therapeutics to treat autoimmune dry eye conditions. This protocol describes a chronic autoimmune dry eye rat model. Lewis rats were immunized with an emulsion containing lacrimal gland extract, ovalbumin, and complete Freund's adjuvant. A second immunization with the same antigens in incomplete Freund's adjuvant was administered two weeks later. These immunizations were administered subcutaneously at the base of the tail. To boost the immune response at the ocular surface and lacrimal glands, lacrimal gland extract and ovalbumin were injected into the forniceal subconjunctiva and lacrimal glands 6 weeks after the first immunization. The rats developed dry eye features, including reduced tear production, decreased tear stability, and increased corneal damage. Immune profiling by flow cytometry showed a preponderance of CD3+ effector memory T cells in the eyeball. PMID:28654074
Application of biomimetics in x-ray optics
NASA Astrophysics Data System (ADS)
Hudec, R.; Remisova, K.
2017-05-01
The principles of biomimetics were successfully applied in X ray optics in the past and recently, e.g. in Lobster-Eye optical systems. However, the recent growing knowledge of sea vision, especially of peculiar mirror eyes of scallops, crustaceans, and deep sea fishes, makes it possible to consider other such applications. One of the most important discoveries is finding of mirror eyes in deep sea fish Dolichopteryx longipes based on large large numbers of very small mirror plates organized in specific positions. This arrangement may even include principles of active optics. We report on ongoing study with focus on understanding of very specific mirror eyes of sea animals and how they may help us to design and develop special optics for scientific applications. We study the ways these mirror eyes work, what are the advantages of these peculiar eye arrangements, and whether these optics can be used in advanced devices, e. g. X-ray optics. We will briefly present and discuss the preliminary results.
A case-control study of eye injuries in the workplace in Hong Kong.
Yu, Tak Sun Ignatius; Liu, Hongjie; Hui, Karen
2004-01-01
Eye injury in the workplace is common worldwide. This study proposed to explore both risk and preventive factors re eye injuries in Hong Kong. Case-control study. A total of 239 work-related eye injury patients, and 253 subjects without a history of any eye injury as controls. Patients with all incident cases of work-related eye injuries attending the ophthalmology clinics of 3 major public hospitals in Hong Kong during the first 3 months of 2000 were invited to participate. Controls were selected from the general population and were frequency matched to patients based on gender. Patients were interviewed face-to-face by trained interviewers in the ophthalmology clinics, using a structured questionnaire. Telephone interviews were used for controls. Risk and protective factors associated with eye injuries. Among eye injury cases, 158 patients (66.1%) reported having incurred 1 episode of eye injury during employment, 49 (20.5%) having suffered 2 episodes, and 32 (13.4%) having experienced >/==" BORDER="0">3 eye injuries at work. Most of the patients (85.4%) did not wear any protective devices at the time of injury. Subjects who wore safety glasses regularly were less likely to have eye injuries (odds ratio [OR] = 0.29, 95% confidence interval [CI] = 0.14-0.62). Having a safety requirement for wearing safety glasses was negatively associated with eye injuries (OR = 0.31, 95% CI = 0.15-0.62). Multivariate analysis indicated that exposures to certain work hazards and working in the construction industry were positively associated with eye injuries. Subjects who worked longer in their current job, who reported having received job safety training before employment, or whose machines or equipment were maintained or repaired regularly by employers were at lower risk of experiencing eye injuries. Construction workers and those exposed to multiple hazards may get eye injuries at work. They should be provided with protective devices that are effective in preventing such exposures. Health education and safety training are important in preventing eye injuries. Maintenance and repair of machines and equipment may effectively reduce or eliminate the sources of exposures.
Recent developments on dry eye disease treatment compounds
Colligris, Basilio; Alkozi, Hanan Awad; Pintor, Jesus
2013-01-01
Dry eye syndrome is a common tears and ocular surface multifactorial disease, described by changes in the ocular surface epithelia related to reduced tears quantity and ocular surface sensitivity, leading to inflammatory reaction. Managing the eye inflammation proved helpful to patients with dry eye disease and current treatment is based on the use of topically applied artificial tear products/lubricants, tear retention management, stimulation of tear secretion and using anti-inflammatory drugs. In this article we revise the corresponding literature and patents assembling the new treatment approaches of novel and future pharmaceutical compounds destined for the dry eye disease treatment. The most frequent categories of compounds presented are secretagogues and anti-inflammatory drugs. These compounds are the research outcome of novel therapeutic strategies designed to reduce key inflammatory pathways and restore healthy tear film. PMID:24526854
Updating OSHA Standards Based on National Consensus Standards; Eye and Face Protection. Final rule.
2016-03-25
On March 13, 2015, OSHA published in the Federal Register a notice of proposed rulemaking (NPRM) to revise its eye and face protection standards for general industry, shipyard employment, marine terminals, longshoring, and construction by updating the references to national consensus standards approved by the American National Standards Institute (ANSI). OSHA received no significant objections from commenters and therefore is adopting the amendments as proposed. This final rule updates the references in OSHA's eye and face standards to reflect the most recent edition of the ANSI/International Safety Equipment Association (ISEA) eye and face protection standard. It removes the oldest-referenced edition of the same ANSI standard. It also amends other provisions of the construction eye and face protection standard to bring them into alignment with OSHA's general industry and maritime standards.
Gatell-Tortajada, Jordi
2016-01-01
To assess the benefits and tolerability of a dietary supplement based on omega-3 fatty acids to relieve dry eye symptoms. A total of 1,419 patients (74.3% women, mean age 58.9 years) with dry eye syndrome using artificial tears participated in a 12-week prospective study. Patients were instructed to take 3 capsules/day of the nutraceutical formulation (Brudysec(®) 1.5 g). Study variables were dry eye symptoms (scratchy and stinging sensation, eye redness, grittiness, painful and tired eyes, grating sensation, and blurry vision), conjunctival hyperemia, tear breakup time (TBUT), Schrimer I test, and Oxford grading scheme. At 12 weeks, each dry eye symptom improved significantly (P<0.001), and the use of artificial tears decreased significantly from 3.77 (standard deviation [SD] =2.08) at baseline to 3.45 (SD =1.72) (P<0.01). In addition, the Schirmer test scores and the TBUT increased significantly, and there was an increase in patients grading 0-I in the Oxford scale and a decrease of those grading IV-V. Significant differences in improvements of dry eye symptoms were also found in compliant versus noncompliant patients as well as in those with moderate/severe versus none/mild conjunctival hyperemia. Oral ω-3 fatty acids supplementation was an effective treatment for dry eye symptoms.
Residencies at The Eye Institute of the Pennsylvania College of Optometry.
ERIC Educational Resources Information Center
Alexander, Arthur H.; Klopfer, Joann
1983-01-01
An optometric residency program at The Eye Institute of the Pennsylvania College of Optometry that focuses on clinical training in the areas of low vision rehabilitation, pediatric optometry, visual training, behavioral vision, primary care optometry and hospital based optometry is discussed. (MSW)
Eye gaze tracking using correlation filters
NASA Astrophysics Data System (ADS)
Karakaya, Mahmut; Bolme, David; Boehnen, Chris
2014-03-01
In this paper, we studied a method for eye gaze tracking that provide gaze estimation from a standard webcam with a zoom lens and reduce the setup and calibration requirements for new users. Specifically, we have developed a gaze estimation method based on the relative locations of points on the top of the eyelid and eye corners. Gaze estimation method in this paper is based on the distances between top point of the eyelid and eye corner detected by the correlation filters. Advanced correlation filters were found to provide facial landmark detections that are accurate enough to determine the subjects gaze direction up to angle of approximately 4-5 degrees although calibration errors often produce a larger overall shift in the estimates. This is approximately a circle of diameter 2 inches for a screen that is arm's length from the subject. At this accuracy it is possible to figure out what regions of text or images the subject is looking but it falls short of being able to determine which word the subject has looked at.
Method of Menu Selection by Gaze Movement Using AC EOG Signals
NASA Astrophysics Data System (ADS)
Kanoh, Shin'ichiro; Futami, Ryoko; Yoshinobu, Tatsuo; Hoshimiya, Nozomu
A method to detect the direction and the distance of voluntary eye gaze movement from EOG (electrooculogram) signals was proposed and tested. In this method, AC-amplified vertical and horizontal transient EOG signals were classified into 8-class directions and 2-class distances of voluntary eye gaze movements. A horizontal and a vertical EOGs during eye gaze movement at each sampling time were treated as a two-dimensional vector, and the center of gravity of the sample vectors whose norms were more than 80% of the maximum norm was used as a feature vector to be classified. By the classification using the k-nearest neighbor algorithm, it was shown that the averaged correct detection rates on each subject were 98.9%, 98.7%, 94.4%, respectively. This method can avoid strict EOG-based eye tracking which requires DC amplification of very small signal. It would be useful to develop robust human interfacing systems based on menu selection for severely paralyzed patients.
A systematic review of best practices in teaching ophthalmology to medical students.
Succar, Tony; Grigg, John; Beaver, Hilary A; Lee, Andrew G
2016-01-01
Ophthalmic medical student education is a cornerstone to improving eye health care globally. We review the current state of the literature, listing barriers to potential best practices for undergraduate ophthalmology teaching and learning within medical curricula. We describe recent advances and pedagogical approaches in ophthalmic education and propose specific recommendations for further improvements and research. Future research should concentrate on developing teaching and learning innovations that may result in a more time- and resource-effective models for interactive and integrated learning. As well as demonstrating that a competency-based approach results not just in better eye health, but also improvements in patient care, education, and medical care in general. By optimizing teaching available through improved evidence-based education, the ultimate goal is to increase medical students' knowledge and produce graduates who are highly trained in eye examination skills, resulting in improved patient eye care through timely diagnosis, referrals, and treatment. Copyright © 2016 Elsevier Inc. All rights reserved.
Silvey, Garry M.; Macri, Jennifer M.; Lee, Paul P.; Lobach, David F.
2005-01-01
New mobile computing devices including personal digital assistants (PDAs) and tablet computers have emerged to facilitate data collection at the point of care. Unfortunately, little research has been reported regarding which device is optimal for a given care setting. In this study we created and compared functionally identical applications on a Palm operating system-based PDA and a Windows-based tablet computer for point-of-care documentation of clinical observations by eye care professionals when caring for patients with diabetes. Eye-care professionals compared the devices through focus group sessions and through validated usability surveys. We found that the application on the tablet computer was preferred over the PDA for documenting the complex data related to eye care. Our findings suggest that the selection of a mobile computing platform depends on the amount and complexity of the data to be entered; the tablet computer functions better for high volume, complex data entry, and the PDA, for low volume, simple data entry. PMID:16779128
Embedding Dimension Selection for Adaptive Singular Spectrum Analysis of EEG Signal.
Xu, Shanzhi; Hu, Hai; Ji, Linhong; Wang, Peng
2018-02-26
The recorded electroencephalography (EEG) signal is often contaminated with different kinds of artifacts and noise. Singular spectrum analysis (SSA) is a powerful tool for extracting the brain rhythm from a noisy EEG signal. By analyzing the frequency characteristics of the reconstructed component (RC) and the change rate in the trace of the Toeplitz matrix, it is demonstrated that the embedding dimension is related to the frequency bandwidth of each reconstructed component, in consistence with the component mixing in the singular value decomposition step. A method for selecting the embedding dimension is thereby proposed and verified by simulated EEG signal based on the Markov Process Amplitude (MPA) EEG Model. Real EEG signal is also collected from the experimental subjects under both eyes-open and eyes-closed conditions. The experimental results show that based on the embedding dimension selection method, the alpha rhythm can be extracted from the real EEG signal by the adaptive SSA, which can be effectively utilized to distinguish between the eyes-open and eyes-closed states.
Kukona, Anuenue; Braze, David; Johns, Clinton L; Mencl, W Einar; Van Dyke, Julie A; Magnuson, James S; Pugh, Kenneth R; Shankweiler, Donald P; Tabor, Whitney
2016-11-01
Recent studies have found considerable individual variation in language comprehenders' predictive behaviors, as revealed by their anticipatory eye movements during language comprehension. The current study investigated the relationship between these predictive behaviors and the language and literacy skills of a diverse, community-based sample of young adults. We found that rapid automatized naming (RAN) was a key determinant of comprehenders' prediction ability (e.g., as reflected in predictive eye movements to a white cake on hearing "The boy will eat the white…"). Simultaneously, comprehension-based measures predicted participants' ability to inhibit eye movements to objects that shared features with predictable referents but were implausible completions (e.g., as reflected in eye movements to a white but inedible white car). These findings suggest that the excitatory and inhibitory mechanisms that support prediction during language processing are closely linked with specific cognitive abilities that support literacy. We show that a self-organizing cognitive architecture captures this pattern of results. Copyright © 2016 Elsevier B.V. All rights reserved.
Amster, Brian; Marquard, Jenna; Henneman, Elizabeth; Fisher, Donald
2015-01-01
In this clinical simulation study using an eye-tracking device, 40% of senior nursing students administered a contraindicated medication to a patient. Our findings suggest that the participants who did not identify the error did not know that amoxicillin is a type of penicillin. Eye-tracking devices may be valuable for determining whether nursing students are making rule- or knowledge-based errors, a distinction not easily captured via observations and interviews.
Mass, A M; Supin, A Ya
2017-03-01
The eye optics and topographic distribution of ganglion cells were studied using whole mount preparations from European beaver Castor fiber L. The beaver eye optics provides emmetropia in air and hypermetropia in water. The optometrical measurements predict retinal resolution of the beaver eye around 17' in air and 9' in water. In air, retinal resolution corresponds to the real visual acuity, whereas in water, visual acuity is below the retinal resolution because of the non-precise focusing.
A Single-Channel EOG-Based Speller.
He, Shenghong; Li, Yuanqing
2017-11-01
Electrooculography (EOG) signals, which can be used to infer the intentions of a user based on eye movements, are widely used in human-computer interface (HCI) systems. Most existing EOG-based HCI systems incorporate a limited number of commands because they generally associate different commands with a few different types of eye movements, such as looking up, down, left, or right. This paper presents a novel single-channel EOG-based HCI that allows users to spell asynchronously by only blinking. Forty buttons corresponding to 40 characters displayed to the user via a graphical user interface are intensified in a random order. To select a button, the user must blink his/her eyes in synchrony as the target button is flashed. Two data processing procedures, specifically support vector machine (SVM) classification and waveform detection, are combined to detect eye blinks. During detection, we simultaneously feed the feature vectors extracted from the ongoing EOG signal into the SVM classification and waveform detection modules. Decisions are made based on the results of the SVM classification and waveform detection. Three online experiments were conducted with eight healthy subjects. We achieved an average accuracy of 94.4% and a response time of 4.14 s for selecting a character in synchronous mode, as well as an average accuracy of 93.43% and a false positive rate of 0.03/min in the idle state in asynchronous mode. The experimental results, therefore, demonstrated the effectiveness of this single-channel EOG-based speller.
Müller, Jana Annina; Wendt, Dorothea; Kollmeier, Birger; Brand, Thomas
2016-01-01
The aim of this study was to validate a procedure for performing the audio-visual paradigm introduced by Wendt et al. (2015) with reduced practical challenges. The original paradigm records eye fixations using an eye tracker and calculates the duration of sentence comprehension based on a bootstrap procedure. In order to reduce practical challenges, we first reduced the measurement time by evaluating a smaller measurement set with fewer trials. The results of 16 listeners showed effects comparable to those obtained when testing the original full measurement set on a different collective of listeners. Secondly, we introduced electrooculography as an alternative technique for recording eye movements. The correlation between the results of the two recording techniques (eye tracker and electrooculography) was r = 0.97, indicating that both methods are suitable for estimating the processing duration of individual participants. Similar changes in processing duration arising from sentence complexity were found using the eye tracker and the electrooculography procedure. Thirdly, the time course of eye fixations was estimated with an alternative procedure, growth curve analysis, which is more commonly used in recent studies analyzing eye tracking data. The results of the growth curve analysis were compared with the results of the bootstrap procedure. Both analysis methods show similar processing durations. PMID:27764125
Combining EEG and eye movement recording in free viewing: Pitfalls and possibilities.
Nikolaev, Andrey R; Meghanathan, Radha Nila; van Leeuwen, Cees
2016-08-01
Co-registration of EEG and eye movement has promise for investigating perceptual processes in free viewing conditions, provided certain methodological challenges can be addressed. Most of these arise from the self-paced character of eye movements in free viewing conditions. Successive eye movements occur within short time intervals. Their evoked activity is likely to distort the EEG signal during fixation. Due to the non-uniform distribution of fixation durations, these distortions are systematic, survive across-trials averaging, and can become a source of confounding. We illustrate this problem with effects of sequential eye movements on the evoked potentials and time-frequency components of EEG and propose a solution based on matching of eye movement characteristics between experimental conditions. The proposal leads to a discussion of which eye movement characteristics are to be matched, depending on the EEG activity of interest. We also compare segmentation of EEG into saccade-related epochs relative to saccade and fixation onsets and discuss the problem of baseline selection and its solution. Further recommendations are given for implementing EEG-eye movement co-registration in free viewing conditions. By resolving some of the methodological problems involved, we aim to facilitate the transition from the traditional stimulus-response paradigm to the study of visual perception in more naturalistic conditions. Copyright © 2016 Elsevier Inc. All rights reserved.
Dose conversion coefficients for neutron exposure to the lens of the human eye.
Manger, R P; Bellamy, M B; Eckerman, K F
2012-03-01
Dose conversion coefficients for the lens of the human eye have been calculated for neutron exposure at energies from 1 × 10(-9) to 20 MeV and several standard orientations: anterior-to-posterior, rotational and right lateral. MCNPX version 2.6.0, a Monte Carlo-based particle transport package, was used to determine the energy deposited in the lens of the eye. The human eyeball model was updated by partitioning the lens into sensitive and insensitive volumes as the anterior portion (sensitive volume) of the lens being more radiosensitive and prone to cataract formation. The updated eye model was used with the adult UF-ORNL mathematical phantom in the MCNPX transport calculations.
Harmening, Wolf M; Tiruveedhula, Pavan; Roorda, Austin; Sincich, Lawrence C
2012-09-01
A special challenge arises when pursuing multi-wavelength imaging of retinal tissue in vivo, because the eye's optics must be used as the main focusing elements, and they introduce significant chromatic dispersion. Here we present an image-based method to measure and correct for the eye's transverse chromatic aberrations rapidly, non-invasively, and with high precision. We validate the technique against hyperacute psychophysical performance and the standard chromatic human eye model. In vivo correction of chromatic dispersion will enable confocal multi-wavelength images of the living retina to be aligned, and allow targeted chromatic stimulation of the photoreceptor mosaic to be performed accurately with sub-cellular resolution.
Cat-eye effect target recognition with single-pixel detectors
NASA Astrophysics Data System (ADS)
Jian, Weijian; Li, Li; Zhang, Xiaoyue
2015-12-01
A prototype of cat-eye effect target recognition with single-pixel detectors is proposed. Based on the framework of compressive sensing, it is possible to recognize cat-eye effect targets by projecting a series of known random patterns and measuring the backscattered light with three single-pixel detectors in different locations. The prototype only requires simpler, less expensive detectors and extends well beyond the visible spectrum. The simulations are accomplished to evaluate the feasibility of the proposed prototype. We compared our results to that obtained from conventional cat-eye effect target recognition methods using area array sensor. The experimental results show that this method is feasible and superior to the conventional method in dynamic and complicated backgrounds.
Deiner, Michael S; Lietman, Thomas M; McLeod, Stephen D; Chodosh, James; Porco, Travis C
2016-09-01
Internet-based search engine and social media data may provide a novel complementary source for better understanding the epidemiologic factors of infectious eye diseases, which could better inform eye health care and disease prevention. To assess whether data from internet-based social media and search engines are associated with objective clinic-based diagnoses of conjunctivitis. Data from encounters of 4143 patients diagnosed with conjunctivitis from June 3, 2012, to April 26, 2014, at the University of California San Francisco (UCSF) Medical Center, were analyzed using Spearman rank correlation of each weekly observation to compare demographics and seasonality of nonallergic conjunctivitis with allergic conjunctivitis. Data for patient encounters with diagnoses for glaucoma and influenza were also obtained for the same period and compared with conjunctivitis. Temporal patterns of Twitter and Google web search data, geolocated to the United States and associated with these clinical diagnoses, were compared with the clinical encounters. The a priori hypothesis was that weekly internet-based searches and social media posts about conjunctivitis may reflect the true weekly clinical occurrence of conjunctivitis. Weekly total clinical diagnoses at UCSF of nonallergic conjunctivitis, allergic conjunctivitis, glaucoma, and influenza were compared using Spearman rank correlation with equivalent weekly data on Tweets related to disease or disease-related keyword searches obtained from Google Trends. Seasonality of clinical diagnoses of nonallergic conjunctivitis among the 4143 patients (2364 females [57.1%] and 1776 males [42.9%]) with 5816 conjunctivitis encounters at UCSF correlated strongly with results of Google searches in the United States for the term pink eye (ρ, 0.68 [95% CI, 0.52 to 0.78]; P < .001) and correlated moderately with Twitter results about pink eye (ρ, 0.38 [95% CI, 0.16 to 0.56]; P < .001) and with clinical diagnosis of influenza (ρ, 0.33 [95% CI, 0.12 to 0.49]; P < .001), but did not significantly correlate with seasonality of clinical diagnoses of allergic conjunctivitis diagnosis at UCSF (ρ, 0.21 [95% CI, -0.02 to 0.42]; P = .06) or with results of Google searches in the United States for the term eye allergy (ρ, 0.13 [95% CI, -0.06 to 0.32]; P = .19). Seasonality of clinical diagnoses of allergic conjunctivitis at UCSF correlated strongly with results of Google searches in the United States for the term eye allergy (ρ, 0.44 [95% CI, 0.24 to 0.60]; P < .001) and eye drops (ρ, 0.47 [95% CI, 0.27 to 0.62]; P < .001). Internet-based search engine and social media data may reflect the occurrence of clinically diagnosed conjunctivitis, suggesting that these data sources can be leveraged to better understand the epidemiologic factors of conjunctivitis.
Niechwiej-Szwedo, E; González, E; Bega, S; Verrier, M C; Wong, A M; Steinbach, M J
2006-07-01
A proprioceptive hypothesis for the control of eye movements has been recently proposed based on neuroanatomical tracing studies. It has been suggested that the non-twitch motoneurons could be involved in modulating the gain of sensory feedback from the eye muscles analogous to the gamma (gamma) motoneurons which control the gain of proprioceptive feedback in skeletal muscles. We conducted behavioral and psychophysical experiments to test the above hypothesis using the Jendrassik Maneuver (JM) to alter the activity of gamma motoneurons. It was hypothesized that the JM would alter the proprioceptive feedback from the eye muscles which would result in misregistration of eye position and mislocalization of targets. In the first experiment, vergence eye movements and pointing responses were examined. Data showed that the JM affected the localization responses but not the actual eye position. Perceptual judgments were tested in the second experiment, and the results showed that targets were perceived as farther when the afferent feedback was altered by the JM. Overall, the results from the two experiments showed that eye position was perceived as more divergent with the JM, but the actual eye movements were not affected. We tested this further in Experiment 3 by examining the effect of JM on the amplitude and velocity of saccadic eye movements. As expected, there were no significant differences in saccadic parameters between the control and experimental conditions. Overall, the present study provides novel insight into the mechanism which may be involved in the use of sensory feedback from the eye muscles. Data from the first two experiments support the hypothesis that the JM alters the registered eye position, as evidenced by the localization errors. We propose that the altered eye position signal is due to the effect of the JM which changes the gain of the sensory feedback from the eye muscles, possibly via the activity of non-twitch motoneurons.
Origami silicon optoelectronics for hemispherical electronic eye systems.
Zhang, Kan; Jung, Yei Hwan; Mikael, Solomon; Seo, Jung-Hun; Kim, Munho; Mi, Hongyi; Zhou, Han; Xia, Zhenyang; Zhou, Weidong; Gong, Shaoqin; Ma, Zhenqiang
2017-11-24
Digital image sensors in hemispherical geometries offer unique imaging advantages over their planar counterparts, such as wide field of view and low aberrations. Deforming miniature semiconductor-based sensors with high-spatial resolution into such format is challenging. Here we report a simple origami approach for fabricating single-crystalline silicon-based focal plane arrays and artificial compound eyes that have hemisphere-like structures. Convex isogonal polyhedral concepts allow certain combinations of polygons to fold into spherical formats. Using each polygon block as a sensor pixel, the silicon-based devices are shaped into maps of truncated icosahedron and fabricated on flexible sheets and further folded either into a concave or convex hemisphere. These two electronic eye prototypes represent simple and low-cost methods as well as flexible optimization parameters in terms of pixel density and design. Results demonstrated in this work combined with miniature size and simplicity of the design establish practical technology for integration with conventional electronic devices.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lesperance, Marielle; Inglis-Whalen, M.; Thomson, R. M., E-mail: rthomson@physics.carleton.ca
Purpose : To investigate the effects of the composition and geometry of ocular media and tissues surrounding the eye on dose distributions for COMS eye plaque brachytherapy with{sup 125}I, {sup 103}Pd, or {sup 131}Cs seeds, and to investigate doses to ocular structures. Methods : An anatomically and compositionally realistic voxelized eye model with a medial tumor is developed based on a literature review. Mass energy absorption and attenuation coefficients for ocular media are calculated. Radiation transport and dose deposition are simulated using the EGSnrc Monte Carlo user-code BrachyDose for a fully loaded COMS eye plaque within a water phantom andmore » our full eye model for the three radionuclides. A TG-43 simulation with the same seed configuration in a water phantom neglecting the plaque and interseed effects is also performed. The impact on dose distributions of varying tumor position, as well as tumor and surrounding tissue media is investigated. Each simulation and radionuclide is compared using isodose contours, dose volume histograms for the lens and tumor, maximum, minimum, and average doses to structures of interest, and doses to voxels of interest within the eye. Results : Mass energy absorption and attenuation coefficients of the ocular media differ from those of water by as much as 12% within the 20–30 keV photon energy range. For all radionuclides studied, average doses to the tumor and lens regions in the full eye model differ from those for the plaque in water by 8%–10% and 13%–14%, respectively; the average doses to the tumor and lens regions differ between the full eye model and the TG-43 simulation by 2%–17% and 29%–34%, respectively. Replacing the surrounding tissues in the eye model with water increases the maximum and average doses to the lens by 2% and 3%, respectively. Substituting the tumor medium in the eye model for water, soft tissue, or an alternate melanoma composition affects tumor dose compared to the default eye model simulation by up to 16%. In the full eye model simulations, the average dose to the lens is larger by 7%–9% than the dose to the center of the lens, and the maximum dose to the optic nerve is 17%–22% higher than the dose to the optic disk for all radionuclides. In general, when normalized to the same prescription dose at the tumor apex, doses delivered to all structures of interest in the full eye model are lowest for{sup 103}Pd and highest for {sup 131}Cs, except for the tumor where the average dose is highest for {sup 103}Pd and lowest for {sup 131}Cs. Conclusions : The eye is not radiologically water-equivalent, as doses from simulations of the plaque in the full eye model differ considerably from doses for the plaque in a water phantom and from simulated TG-43 calculated doses. This demonstrates the importance of model-based dose calculations for eye plaque brachytherapy, for which accurate elemental compositions of ocular media are necessary.« less
Castro, Luis A; Favela, Jesus; Garcia-Peña, Carmen
2014-11-01
The transition from paper to electronic-based records in the healthcare industry has posed several challenges to conventional medical practices. The introduction of technology in day-to-day medical and nursing practices deserves careful consideration. In this work, we report the results of a controlled experiment to compare nurses' consultation in emergency calls in six different conditions. We studied the effect that the type of communication media (face-to-face, telephone, videoconference) and type of nursing protocol media (paper-based, electronic-based) can have on consultation time, mistakes made, pauses during consultation, eye contact, and efficacy of the consultation. We found that the type of communication media has an effect on consultation time; on average, fewer mistakes were made during telephone-based consultations; for eye contact, there were significantly fewer eye contacts during face-to-face than during videoconference consultations; finally, the type of communication media or protocol media did not have any effect in the efficacy of the consultation.
Importance of population-based studies in clinical practice
Ronnie, George; Ve, Ramesh Sathyamangalam; Velumuri, Lokapavani; Asokan, Rashima; Vijaya, Lingam
2011-01-01
In the last decade, there have been reports on the prevalence of glaucoma from the Vellore Eye Survey, Andhra Pradesh Eye Diseases Survey, Aravind Comprehensive Eye Survey, Chennai Glaucoma Study and West Bengal Glaucoma Study. Population-based studies provide important information regarding the prevalence and risk factors for glaucoma. They also highlight regional differences in the prevalence of various types of glaucoma. It is possible to gather important insights regarding the number of persons affected with glaucoma and the proportion with undiagnosed disease. We reviewed the different population-based studies from India and compare their findings. The lacunae in ophthalmic care that can be inferred from these studies are identified and possible reasons and solutions are discussed. We also discuss the clinical relevance of the various findings, and how it reflects on clinical practice in the country. Since India has a significantly high disease burden, we examine the possibility of population-based screening for disease in the Indian context. PMID:21150021
Diabetic retinopathy in a hospital eye clinic population in Honiara, Solomon Islands.
Qoqonokana, Mundi Qalo; Brian, Garry; Ramke, Jacqueline; Garcia, Jose; Szetu, John
2010-12-01
To determine the presence, severity and context of diabetic retinopathy among diabetic adults using hospital eye clinic services in Honiara, Solomon Islands. Fifty consecutive known diabetic patients aged ≥20 years were interviewed and underwent Snellen distance vision testing and complete ocular examination, including dilated 90 D funduscopy. Diabetic retinopathy was graded according to the International Clinical Diabetic Retinopathy and Macular Oedema Disease Severity Scales. Participants were predominantly Melanesian (94%). Mean age was 53.6 ± 10.7 years; 42% were female; and 34% were rural dwellers. Diabetes had been diagnosed <5, 5-10 and >10 years ago for 42%, 34% and 24% of participants. However, 54% denied ever having had a dilated fundus examination. Proliferative retinopathy, severe non-proliferative changes and maculopathy were present in 5, 12 and 26 eyes, respectively. For the 32 eyes with pinhole acuity ≤6/12, diabetic eye disease was the cause for 20, with all but one due to maculopathy. Diabetes reduced the pinhole vision of five eyes to ≤6/60. Twenty-four per cent of participants had diabetes-related pinhole vision ≤6/12 in at least one eye. Those diagnosed with diabetes 5-10 and >10 years were 17.5 and 58.8 times more likely to have such an eye compared with those recently (<5 years) diagnosed (extended Mantel-Haenszel χ² = 11.570, P < 0.001). Participants were not well informed about diabetic eye disease. Diabetic eye disease is now a significant contributor to this clinic's workload. A population-based survey is needed to quantify the problem and inform design and delivery of eye services for this chronic disease. © 2010 The Authors. Clinical and Experimental Ophthalmology © 2010 Royal Australian and New Zealand College of Ophthalmologists.
Principi, S; Farah, J; Ferrari, P; Carinou, E; Clairand, I; Ginjaume, M
2016-09-01
This paper aims to provide some practical recommendations to reduce eye lens dose for workers exposed to X-rays in interventional cardiology and radiology and also to propose an eye lens correction factor when lead glasses are used. Monte Carlo simulations are used to study the variation of eye lens exposure with operator position, height and body orientation with respect to the patient and the X-ray tube. The paper also looks into the efficiency of wraparound lead glasses using simulations. Computation results are compared with experimental measurements performed in Spanish hospitals using eye lens dosemeters as well as with data from available literature. Simulations showed that left eye exposure is generally higher than the right eye, when the operator stands on the right side of the patient. Operator height can induce a strong dose decrease by up to a factor of 2 for the left eye for 10-cm-taller operators. Body rotation of the operator away from the tube by 45°-60° reduces eye exposure by a factor of 2. The calculation-based correction factor of 0.3 for wraparound type lead glasses was found to agree reasonably well with experimental data. Simple precautions, such as the positioning of the image screen away from the X-ray source, lead to a significant reduction of the eye lens dose. Measurements and simulations performed in this work also show that a general eye lens correction factor of 0.5 can be used when lead glasses are worn regardless of operator position, height and body orientation. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Yoo, Tae Keun; Han, Sueng-Han; Han, Jinu
2017-12-01
To determine the efficacy of a biodegradable Ologen (Aeon Astron Europe BV, Leiden, The Netherlands) collagen matrix in reducing the blue color change due to exposed thinned sclera after strabismus surgery. Fourteen patients with intermittent exotropia undergoing symmetric bilateral lateral rectus recession surgery were included in this prospective, randomized, paired-eye controlled study. In each patient, Ologen was implanted at the original rectus insertion site in one randomly selected eye; the other eye underwent conventional surgery. Ologen was inserted under the conjunctiva without suturing, covering the muscle insertion site. Conjunctival color change was analyzed using computer-based image analysis immediately and 1 week, 1 month, and 3 months postoperatively. Slit-lamp photographs of each eye were evaluated using contrast limited adaptive histogram equalization (CLAHE), Canny edge, and the RGB (red-green-blue) model. Secondary outcomes were conjunctival and sclera thickness 3 months postoperatively determined by anterior segment optical coherence tomography. Immediately and 1 week postoperatively all color models showed no significant differences between Ologen-implanted and control eyes. Three months postoperatively, Ologen-implanted eyes exhibited significantly lower CLAHE (P = 0.041) and RGB model blue color (P = 0.008) values than control eyes. Canny edge (P = 0.061) and RGB model red color (P = 0.152) values did not differ between eyes. Conjunctival stroma and episcleral complex thickness was greater in Ologen-implanted eyes than in controls (P = 0.001). Blue color change was significantly less noticeable in Ologen-implanted eyes than in controls. Thus, Ologen implantation helps prevent visible blue sclera at the original rectus insertion site after lateral rectus recession. Copyright © 2017 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.
Anxiety symptoms and children's eye gaze during fear learning.
Michalska, Kalina J; Machlin, Laura; Moroney, Elizabeth; Lowet, Daniel S; Hettema, John M; Roberson-Nay, Roxann; Averbeck, Bruno B; Brotman, Melissa A; Nelson, Eric E; Leibenluft, Ellen; Pine, Daniel S
2017-11-01
The eye region of the face is particularly relevant for decoding threat-related signals, such as fear. However, it is unclear if gaze patterns to the eyes can be influenced by fear learning. Previous studies examining gaze patterns in adults find an association between anxiety and eye gaze avoidance, although no studies to date examine how associations between anxiety symptoms and eye-viewing patterns manifest in children. The current study examined the effects of learning and trait anxiety on eye gaze using a face-based fear conditioning task developed for use in children. Participants were 82 youth from a general population sample of twins (aged 9-13 years), exhibiting a range of anxiety symptoms. Participants underwent a fear conditioning paradigm where the conditioned stimuli (CS+) were two neutral faces, one of which was randomly selected to be paired with an aversive scream. Eye tracking, physiological, and subjective data were acquired. Children and parents reported their child's anxiety using the Screen for Child Anxiety Related Emotional Disorders. Conditioning influenced eye gaze patterns in that children looked longer and more frequently to the eye region of the CS+ than CS- face; this effect was present only during fear acquisition, not at baseline or extinction. Furthermore, consistent with past work in adults, anxiety symptoms were associated with eye gaze avoidance. Finally, gaze duration to the eye region mediated the effect of anxious traits on self-reported fear during acquisition. Anxiety symptoms in children relate to face-viewing strategies deployed in the context of a fear learning experiment. This relationship may inform attempts to understand the relationship between pediatric anxiety symptoms and learning. © 2017 Association for Child and Adolescent Mental Health.
Roberts, Philipp K; Goldstein, Debra A; Fawzi, Amani A
2017-08-01
Purpose/Aim of the study: To assess the ability of optical coherence tomographic angiography (OCTA) to visualize the normal iris vasculature as well as neovascularization of the iris (NVI). Study participants with healthy eyes, patients at risk of NVI development and patients with active or regressed NVI were consecutively included in this cross-sectional observational study. Imaging was performed using a commercially available OCTA system (RTVue- XR Avanti, Optovue Inc., Fremont, CA, USA). Abnormal iris vessels were graded on OCTA according to a modified clinical staging system and compared to slitlamp and gonioscopic findings. Fifty eyes of 26 study participants (16 healthy eyes, 19 eyes at risk, 15 eyes with different stages of NVI) were imaged using OCTA. In 11 out of 16 healthy eyes (69%) with light or moderately dark iris pigmentation, we observed physiological, radially aligned iris vasculature on OCTA imaging, which could not be visualized in five eyes (31%) with darkly pigmented irides. One eye in the "eyes at risk" group was diagnosed with NVI based on OCTA, which was not observed clinically. Fifteen eyes with clinically active or regressed NVI were imaged. Different stages of NVI could be differentiated by OCTA, corresponding well to an established clinical grading system. Four eyes showed regressed NVI by OCTA, not seen clinically, and were graded as a newly defined stage 4. This pilot clinical study showed that OCTA for imaging of the iris vasculature in health and disease is highly dependent on iris pigmentation. Fine, clinically invisible iris vessels can be visualized by OCTA in the very early stages as well as in the regressed stage of NVI.
Roberts, Philipp K.; Goldstein, Debra A.; Fawzi, Amani A.
2017-01-01
Purpose/Aim of the study To assess the ability of optical coherence tomographic angiography (OCTA) to visualize the normal iris vasculature as well as neovascularization of the iris (NVI). Materials and Methods Study participants with healthy eyes, patients at risk of NVI development and patients with active or regressed NVI were consecutively included in this cross-sectional observational study. Imaging was performed using a commercially available OCTA system (RTVue- XR Avanti, Optovue Inc., Fremont, CA, USA). Abnormal iris vessels were graded on OCTA according to a modified clinical staging system and compared to slitlamp and gonioscopic findings. Results Fifty eyes of 26 study participants (16 healthy eyes, 19 eyes at risk, 15 eyes with different stages of NVI) were imaged using OCTA. In 11 out of 16 healthy eyes (69%) with light or moderately dark iris pigmentation, we observed physiological, radially aligned iris vasculature on OCTA imaging, which could not be visualized in five eyes (31%) with darkly pigmented irides. One eye in the “eyes at risk” group was diagnosed with NVI based on OCTA, which was not observed clinically. Fifteen eyes with clinically active or regressed NVI were imaged. Different stages of NVI could be differentiated by OCTA, corresponding well to an established clinical grading system. Four eyes showed regressed NVI by OCTA, not seen clinically, and were graded as a newly defined stage 4. Conclusions This pilot clinical study showed that OCTA for imaging of the iris vasculature in health and disease is highly dependent on iris pigmentation. Fine, clinically invisible iris vessels can be visualized by OCTA in the very early stages as well as in the regressed stage of NVI. PMID:28441067
Designs and Algorithms to Map Eye Tracking Data with Dynamic Multielement Moving Objects.
Kang, Ziho; Mandal, Saptarshi; Crutchfield, Jerry; Millan, Angel; McClung, Sarah N
2016-01-01
Design concepts and algorithms were developed to address the eye tracking analysis issues that arise when (1) participants interrogate dynamic multielement objects that can overlap on the display and (2) visual angle error of the eye trackers is incapable of providing exact eye fixation coordinates. These issues were addressed by (1) developing dynamic areas of interests (AOIs) in the form of either convex or rectangular shapes to represent the moving and shape-changing multielement objects, (2) introducing the concept of AOI gap tolerance (AGT) that controls the size of the AOIs to address the overlapping and visual angle error issues, and (3) finding a near optimal AGT value. The approach was tested in the context of air traffic control (ATC) operations where air traffic controller specialists (ATCSs) interrogated multiple moving aircraft on a radar display to detect and control the aircraft for the purpose of maintaining safe and expeditious air transportation. In addition, we show how eye tracking analysis results can differ based on how we define dynamic AOIs to determine eye fixations on moving objects. The results serve as a framework to more accurately analyze eye tracking data and to better support the analysis of human performance.
Designs and Algorithms to Map Eye Tracking Data with Dynamic Multielement Moving Objects
Mandal, Saptarshi
2016-01-01
Design concepts and algorithms were developed to address the eye tracking analysis issues that arise when (1) participants interrogate dynamic multielement objects that can overlap on the display and (2) visual angle error of the eye trackers is incapable of providing exact eye fixation coordinates. These issues were addressed by (1) developing dynamic areas of interests (AOIs) in the form of either convex or rectangular shapes to represent the moving and shape-changing multielement objects, (2) introducing the concept of AOI gap tolerance (AGT) that controls the size of the AOIs to address the overlapping and visual angle error issues, and (3) finding a near optimal AGT value. The approach was tested in the context of air traffic control (ATC) operations where air traffic controller specialists (ATCSs) interrogated multiple moving aircraft on a radar display to detect and control the aircraft for the purpose of maintaining safe and expeditious air transportation. In addition, we show how eye tracking analysis results can differ based on how we define dynamic AOIs to determine eye fixations on moving objects. The results serve as a framework to more accurately analyze eye tracking data and to better support the analysis of human performance. PMID:27725830
Shoshi, Mire; Shoshi, Avdyl; Xhafa, Agim; Kastrati, Fetije; Shoshi, Fitore; Shoshi, Fjolla
2012-01-01
In the Eye Clinic during 2008-2010 we have treated 446 patients, where 252 were hospitalized patients while 184 weren't. Treated patients were 1-85 years old. AIM OF THIS STUDY is to present our experience in treatment of patients with eye lids injuries and their reconstruction. In patients that were treated in the Eye Clinic, we have applied surgical methods, anti-tetanic protection and local and general medical therapy. 252 hospitalized patients also had other injuries of eye such as: rupture of bulbus, traumatic cataract, prolapsus iris, hyphaema in CA, prolapsus CV, VLC perforanc cornea et corpus alieni in CA, hyphaema totalis, VLC sclera, corpus alieni intrabulbares. Patients that weren't hospitalized were 5-10 years old, 25-35 years old and 20-25 years old. Hospitalized patients were 5-10 years old, 20-25 years old and 30-35 years old. By this we can conclude that there wasn't any significant difference based on the patients' age. In the hospitalized cases with eye-lid injuries, most injuries of the eye were: VLC perforanc cornea cum prolapsus iridea, Corpus alieni in CA et hyphaema.
Signal-dependent noise determines motor planning
NASA Astrophysics Data System (ADS)
Harris, Christopher M.; Wolpert, Daniel M.
1998-08-01
When we make saccadic eye movements or goal-directed arm movements, there is an infinite number of possible trajectories that the eye or arm could take to reach the target,. However, humans show highly stereotyped trajectories in which velocity profiles of both the eye and hand are smooth and symmetric for brief movements,. Here we present a unifying theory of eye and arm movements based on the single physiological assumption that the neural control signals are corrupted by noise whose variance increases with the size of the control signal. We propose that in the presence of such signal-dependent noise, the shape of a trajectory is selected to minimize the variance of the final eye or arm position. This minimum-variance theory accurately predicts the trajectories of both saccades and arm movements and the speed-accuracy trade-off described by Fitt's law. These profiles are robust to changes in the dynamics of the eye or arm, as found empirically,. Moreover, the relation between path curvature and hand velocity during drawing movements reproduces the empirical `two-thirds power law',. This theory provides a simple and powerful unifying perspective for both eye and arm movement control.
Lee, Won June; Na, Kyeong Ik; Kim, Young Kook; Jeoung, Jin Wook; Park, Ki Ho
2017-06-01
To evaluate the diagnostic ability of wide-field retinal nerve fiber layer (RNFL) maps with swept-source optical coherence tomography (SS-OCT) for detection of preperimetric (PPG) and early perimetric glaucoma (EG). One hundred eighty-four eyes, including 67 healthy eyes, 43 eyes with PPG, and 74 eyes with EG, were analyzed. Patients underwent a comprehensive ocular examination including red-free RNFL photography, visual field testing and wide-field SS-OCT scanning (DRI-OCT-1 Atlantis; Topcon, Tokyo, Japan). SS-OCT provides a wide-field RNFL thickness map and a SuperPixel map, which are composed of the RNFL deviation map of the peripapillary area and the deviation map of the composition of the ganglion cell layer with the inner plexiform layer and RNFL (GC-IPL+RNFL) in the macular area. The ability to discriminate PPG and EG from healthy eyes was assessed using sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) for all parameters and criteria provided by the wide-field SS-OCT scan. The wide-field RNFL thickness map using SS-OCT showed the highest sensitivity of PPG-diagnostic and EG-diagnostic performance compared with the other SS-OCT criteria based on the internal normative base (93.0 and 97.3%, respectively). Among the SS-OCT continuous parameters, the RFNL thickness of the 7 clock-hour, inferior and inferotemporal macular ganglion cell analyses showed the largest AUC of PPG-diagnostic and EG-diagnostic performance (AUC=0.809 to 0.865). The wide-field RNFL thickness map using SS-OCT performed well in distinguishing eyes with PPG and EG from healthy eyes. In the clinical setting, wide-field RNFL maps of SS-OCT can be useful tools for detection of early-stage glaucoma.
Use of traditional eye medicine and self-medication in rural India: A population-based study.
Gupta, Noopur; Vashist, Praveen; Tandon, Radhika; Gupta, Sanjeev K; Kalaivani, Mani; Dwivedi, S N
2017-01-01
To determine the type and nature of traditional eye medicine (TEM), their sources and use and practices related to self-medication for ophthalmic diseases in a rural Indian population. A population-based, cross-sectional study was conducted in 25 randomly selected clusters of Rural Gurgaon, Haryana, India as part of CORE (Cornea Opacity Rural Epidemiological) study. In addition to comprehensive ophthalmic examination, health-seeking behavior and use of self-medication and TEM was assessed in the adult population using a semi-structured questionnaire. Physical verification of available ophthalmic medications in the enumerated households was conducted by the study team. Descriptive statistics were computed along with multivariable logistic regression analysis to determine associated factors for use of self-medication and TEM. Of the 2160 participants interviewed, 396 (18.2%) reported using ophthalmic medications without consulting an ophthalmologist, mainly for symptoms like watering (37.1%), redness (27.7%), itching (19.2%) and infection (13.6%). On physical verification of available eye drops that were being used without prescription, 26.4% participants were practicing self-medication. Steroid, expired/unlabeled and indigenous eye drops were being used by 151(26.5%), 120(21.1%) and 75 (13.2%) participants respectively. Additionally, 25.7% (529) participants resorted to home remedies like 'kajal'(61.4%), honey (31.4%), ghee (11.7%) and rose water (9.1%). Use of TEM is prevalent in this population. The rampant use of steroid eye drops without prescription along with use of expired or unlabelled eye drops warrants greater emphasis on safe eye care practices in this population. Public awareness and regulatory legislations must be implemented to decrease harmful effects arising due to such practices.
Chung, So-Hyang; Lim, Sung A; Tchach, Hungwon
2016-02-01
To evaluate the efficacy and safety profile of carbomer-based lipid-containing artificial tear formulations (CBLAT) in patients with dry eye syndrome. A multicenter parallel-group study was conducted in 412 patients with dry eye syndrome. Of these patients, 221 switched from using artificial tears to CBLAT (switching group) and 191 added CBLAT to their current treatment (add-on group). Ocular symptom scores, ocular staining grades, tear film breakup time (tBUT), Schirmer I test value, and Korean dry eye level (as defined by the Korean Corneal Disease Study Group guidelines) were evaluated at baseline and after 4 weeks of treatment. After 4 weeks of treatment, ocular surface staining grade, tBUT, Schirmer I value, ocular irritation symptom scores, and the positive rate of visual symptom improved significantly in both groups. Mean reductions in ocular surface staining grades (-0.8 ± 0.9) and ocular irritation symptom scores (-0.8 ± 0.8) in the add-on group were significantly higher than those (-0.5 ± 0.8 and -0.6 ± 0.8) in the switching group (P < 0.01 and P < 0.05). The positive rate of visual symptoms (44.2%) in the add-on group was significantly higher than that (26.4%) in the switching group (P < 0.01). The decrease of Korean dry eye level was 30.1% in the switching group and 51.6% in the add-on group. More patients in the add-on group had decreased dry eye levels than those in the switching group (P < 0.0001). CBLAT improves ocular surface staining grades, tBUT, Schirmer I values, and ocular symptoms in patients with dry eye syndrome.
Eibenberger, Karin; Eibenberger, Bernhard; Rucci, Michele
2016-08-01
The precise measurement of eye movements is important for investigating vision, oculomotor control and vestibular function. The magnetic scleral search coil technique is one of the most precise measurement techniques for recording eye movements with very high spatial (≈ 1 arcmin) and temporal (>kHz) resolution. The technique is based on measuring voltage induced in a search coil through a large magnetic field. This search coil is embedded in a contact lens worn by a human subject. The measured voltage is in direct relationship to the orientation of the eye in space. This requires a magnetic field with a high homogeneity in the center, since otherwise the field inhomogeneity would give the false impression of a rotation of the eye due to a translational movement of the head. To circumvent this problem, a bite bar typically restricts head movement to a minimum. However, the need often emerges to precisely record eye movements under natural viewing conditions. To this end, one needs a uniform magnetic field that is uniform over a large area. In this paper, we present the numerical and finite element simulations of the magnetic flux density of different coil geometries that could be used for search coil recordings. Based on the results, we built a 2.2 × 2.2 × 2.2 meter coil frame with a set of 3 × 4 coils to generate a 3D magnetic field and compared the measured flux density with our simulation results. In agreement with simulation results, the system yields a highly uniform field enabling high-resolution recordings of eye movements.
Labetoulle, Marc; Messmer, Elisabeth M; Pisella, Pierre-Jean; Ogundele, Abayomi; Baudouin, Christophe
2017-04-01
To demonstrate non-inferiority of a hydroxypropyl guar/polyethylene glycol/propylene glycol lubricating eye-drop (HPG/PEG/PG) compared with an osmoprotective carboxymethylcellulose/glycerine eye-drop (O/CMC) for ocular surface staining. This was a multicentre, randomised, observer-masked, parallel-group study. Adults with dry eye instilled HPG/PEG/PG/ or O/CMC 4 times daily for 35 days and then as needed through day 90. Total ocular surface staining (TOSS) score changes from baseline and Impact of Dry Eye on Everyday Life (IDEEL) treatment satisfaction module scores were assessed. Non-inferiority, based on TOSS score change from baseline, was concluded if the upper limit of the 2-sided CI was <2 units. Mean±SD patient age was 64.4±13.7 years; 94 patients were randomised to treatment (HPG/PEG/PG, n=46; O/CMC, n=48). Mean±SE TOSS score change from baseline to day 35 was -2.2±0.33 with HPG/PEG/PG and -1.7±0.47 with O/CMC (treatment difference, -0.47±0.47; p=0.38), and the non-inferiority criterion was met. IDEEL treatment satisfaction scores were similar between groups at day 35 and day 90. The most frequently reported adverse event was eye irritation (HPG/PEG/PG, n=2; O/CMC, n=3). HPG/PEG/PG and O/CMC reduced ocular surface damage, and HPG/PEG/PG was non-inferior to O/CMC. Both treatments were effective, convenient and well tolerated. NCT01863368, Results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Diagnostic accuracy of eye movements in assessing pedophilia.
Fromberger, Peter; Jordan, Kirsten; Steinkrauss, Henrike; von Herder, Jakob; Witzel, Joachim; Stolpmann, Georg; Kröner-Herwig, Birgit; Müller, Jürgen Leo
2012-07-01
Given that recurrent sexual interest in prepubescent children is one of the strongest single predictors for pedosexual offense recidivism, valid and reliable diagnosis of pedophilia is of particular importance. Nevertheless, current assessment methods still fail to fulfill psychometric quality criteria. The aim of the study was to evaluate the diagnostic accuracy of eye-movement parameters in regard to pedophilic sexual preferences. Eye movements were measured while 22 pedophiles (according to ICD-10 F65.4 diagnosis), 8 non-pedophilic forensic controls, and 52 healthy controls simultaneously viewed the picture of a child and the picture of an adult. Fixation latency was assessed as a parameter for automatic attentional processes and relative fixation time to account for controlled attentional processes. Receiver operating characteristic (ROC) analyses, which are based on calculated age-preference indices, were carried out to determine the classifier performance. Cross-validation using the leave-one-out method was used to test the validity of classifiers. Pedophiles showed significantly shorter fixation latencies and significantly longer relative fixation times for child stimuli than either of the control groups. Classifier performance analysis revealed an area under the curve (AUC) = 0.902 for fixation latency and an AUC = 0.828 for relative fixation time. The eye-tracking method based on fixation latency discriminated between pedophiles and non-pedophiles with a sensitivity of 86.4% and a specificity of 90.0%. Cross-validation demonstrated good validity of eye-movement parameters. Despite some methodological limitations, measuring eye movements seems to be a promising approach to assess deviant pedophilic interests. Eye movements, which represent automatic attentional processes, demonstrated high diagnostic accuracy. © 2012 International Society for Sexual Medicine.
Use of traditional eye medicine and self-medication in rural India: A population-based study
Gupta, Noopur; Tandon, Radhika; Gupta, Sanjeev K.; Kalaivani, Mani; Dwivedi, S. N.
2017-01-01
Objective To determine the type and nature of traditional eye medicine (TEM), their sources and use and practices related to self-medication for ophthalmic diseases in a rural Indian population. Methods A population-based, cross-sectional study was conducted in 25 randomly selected clusters of Rural Gurgaon, Haryana, India as part of CORE (Cornea Opacity Rural Epidemiological) study. In addition to comprehensive ophthalmic examination, health-seeking behavior and use of self-medication and TEM was assessed in the adult population using a semi-structured questionnaire. Physical verification of available ophthalmic medications in the enumerated households was conducted by the study team. Descriptive statistics were computed along with multivariable logistic regression analysis to determine associated factors for use of self-medication and TEM. Results Of the 2160 participants interviewed, 396 (18.2%) reported using ophthalmic medications without consulting an ophthalmologist, mainly for symptoms like watering (37.1%), redness (27.7%), itching (19.2%) and infection (13.6%). On physical verification of available eye drops that were being used without prescription, 26.4% participants were practicing self-medication. Steroid, expired/unlabeled and indigenous eye drops were being used by 151(26.5%), 120(21.1%) and 75 (13.2%) participants respectively. Additionally, 25.7% (529) participants resorted to home remedies like ‘kajal’(61.4%), honey (31.4%), ghee (11.7%) and rose water (9.1%). Conclusion Use of TEM is prevalent in this population. The rampant use of steroid eye drops without prescription along with use of expired or unlabelled eye drops warrants greater emphasis on safe eye care practices in this population. Public awareness and regulatory legislations must be implemented to decrease harmful effects arising due to such practices. PMID:28829812
Li, Yan; Chamberlain, Winston; Tan, Ou; Brass, Robert; Weiss, Jack L.; Huang, David
2016-01-01
PURPOSE To screen for subclinical keratoconus by analyzing corneal, epithelial, and stromal thickness map patterns with Fourier-domain optical coherence tomography (OCT). SETTING Four centers in the United States. DESIGN Cross-sectional observational study. METHODS Eyes of normal subjects, subclinical keratoconus eyes, and the topographically normal eye of a unilateral keratoconus patient were studied. Corneas were scanned using a 26 000 Hz Fourier-domain OCT system (RTVue). Normal subjects were divided into training and evaluation groups. Corneal, epithelial, and stromal thickness maps and derived diagnostic indices, including pattern standard deviation (PSD) variables and pachymetric map–based keratoconus risk scores were calculated from the OCT data. Area under the receiver operating characteristic curve (AUC) analysis was used to evaluate the diagnostic accuracy of the indices. RESULTS The study comprised 150 eyes of 83 normal subjects, 50 subclinical keratoconus eyes of 32 patients, and 1 topographically normal eye of a unilateral keratoconus patient. Subclinical keratoconus was characterized by inferotemporal thinning of the cornea, epithelium, and stroma. The PSD values for corneal (P < .001), epithelial (P < .001), and stromal (P = .049) thickness maps were all significantly higher in subclinical keratoconic eyes than in the normal group. The diagnostic accuracy was significantly higher for PSD variables (pachymetric PSD, AUC = 0.941; epithelial PSD, AUC = 0.985; stromal PSD, AUC = 0.924) than for the pachymetric map–based keratoconus risk score (AUC = 0.735). CONCLUSIONS High-resolution Fourier-domain OCT could map corneal, epithelial, and stromal thicknesses. Corneal and sublayer thickness changes in subclinical keratoconus could be detected with high accuracy using PSD variables. These new diagnostic variables might be useful in the detection of early keratoconus. PMID:27026454
Joint representation of translational and rotational components of optic flow in parietal cortex
Sunkara, Adhira; DeAngelis, Gregory C.; Angelaki, Dora E.
2016-01-01
Terrestrial navigation naturally involves translations within the horizontal plane and eye rotations about a vertical (yaw) axis to track and fixate targets of interest. Neurons in the macaque ventral intraparietal (VIP) area are known to represent heading (the direction of self-translation) from optic flow in a manner that is tolerant to rotational visual cues generated during pursuit eye movements. Previous studies have also reported that eye rotations modulate the response gain of heading tuning curves in VIP neurons. We tested the hypothesis that VIP neurons simultaneously represent both heading and horizontal (yaw) eye rotation velocity by measuring heading tuning curves for a range of rotational velocities of either real or simulated eye movements. Three findings support the hypothesis of a joint representation. First, we show that rotation velocity selectivity based on gain modulations of visual heading tuning is similar to that measured during pure rotations. Second, gain modulations of heading tuning are similar for self-generated eye rotations and visually simulated rotations, indicating that the representation of rotation velocity in VIP is multimodal, driven by both visual and extraretinal signals. Third, we show that roughly one-half of VIP neurons jointly represent heading and rotation velocity in a multiplicatively separable manner. These results provide the first evidence, to our knowledge, for a joint representation of translation direction and rotation velocity in parietal cortex and show that rotation velocity can be represented based on visual cues, even in the absence of efference copy signals. PMID:27095846
Heo, Hwan; Lee, Won Oh; Shin, Kwang Yong; Park, Kang Ryoung
2014-01-01
We propose a new method for measuring the degree of eyestrain on 3D stereoscopic displays using a glasses-type of eye tracking device. Our study is novel in the following four ways: first, the circular area where a user's gaze position exists is defined based on the calculated gaze position and gaze estimation error. Within this circular area, the position where edge strength is maximized can be detected, and we determine this position as the gaze position that has a higher probability of being the correct one. Based on this gaze point, the eye foveation model is defined. Second, we quantitatively evaluate the correlation between the degree of eyestrain and the causal factors of visual fatigue, such as the degree of change of stereoscopic disparity (CSD), stereoscopic disparity (SD), frame cancellation effect (FCE), and edge component (EC) of the 3D stereoscopic display using the eye foveation model. Third, by comparing the eyestrain in conventional 3D video and experimental 3D sample video, we analyze the characteristics of eyestrain according to various factors and types of 3D video. Fourth, by comparing the eyestrain with or without the compensation of eye saccades movement in 3D video, we analyze the characteristics of eyestrain according to the types of eye movements in 3D video. Experimental results show that the degree of CSD causes more eyestrain than other factors. PMID:24834910
Cotovio, José; Grandidier, Marie-Hélène; Lelièvre, Damien; Bremond, Christelle; Amsellem, Carolle; Maloug, Saber; Ovigne, Jean-Marc; Loisel-Joubert, Sophie; Lee, Aline Van Der; Minondo, Anne-Marie; Capallere, Christophe; Bertino, Béatrice; Alépée, Nathalie; Tinois-Tessonneaud, Estelle; de Fraissinette, Anne De Brugerolle; Meunier, Jean-Roch; Leclaire, Jacques
2010-03-01
The 7th amendment of the EU Cosmetics Directive led to the ban of eye irritation testing for cosmetic ingredients in animals, effective from March 11th 2009. Over the last 20years, many efforts have been made to find reliable and relevant alternative methods. The SkinEthic HCE model was used to evaluate the in vitro eye irritancy potential of substances from a cosmetic industry portfolio. An optimized protocol based on a specific 1-h treatment and a 16-h post-treatment incubation period was first assessed on a set of 102 substances. The prediction model (PM) based on a 50% viability cut-off, allowed to draw up two classes (Irritants and Non-Irritants), with good associated sensitivity (86.2%) and specificity (83.5%). To check the robustness of the method, the evaluated set was expanded up to 435 substances. Final performances maintained a high level and were characterized by an overall accuracy value > 82% when using EU or GHS classification rules. Results showed that the SkinEthic HCE test method is a promising in vitro tool for the prediction of eye irritancy. Optimization datasets were shared with the COLIPA Eye Irritation Project Team and ECVAM experts, and reviewed as part of an ongoing progression to enter an ECVAM prospective validation study for eye irritation. Copyright (c) 2009 Elsevier Ltd. All rights reserved.
Atypical cytomegalovirus retinitis in non-Hodgkin's lymphoma.
Tyagi, Mudit; Ambiya, Vikas; Mathai, Annie; Narayanan, Raja
2015-08-03
A 54-year-old woman, a known case of non-Hodgkin's lymphoma (NHL) in complete remission, presented with floaters and diminution of vision in her left eye. The eye had vitritis with non-haemorrhagic retinitis mimicking intraocular lymphoma and acute retinal necrosis. A vitreous sample was positive for cytomegalovirus (CMV) and herpes simplex virus 1 (HSV-1) DNA by PCR. The possibility of intraocular lymphoma was not confirmed by the immunohistochemistry of the vitreous sample. The patient had a relapse of NHL along with rapid deterioration of vision in her left eye to no perception of light, due to optic nerve involvement. The right eye developed a new patch of focal haemorrhagic retinitis threatening the fovea. Based on the laboratory results and the clinical findings, she was successfully managed as a case of bilateral CMV retinitis and the vision in her right eye was salvaged. 2015 BMJ Publishing Group Ltd.
Real-time estimation of horizontal gaze angle by saccade integration using in-ear electrooculography
2018-01-01
The manuscript proposes and evaluates a real-time algorithm for estimating eye gaze angle based solely on single-channel electrooculography (EOG), which can be obtained directly from the ear canal using conductive ear moulds. In contrast to conventional high-pass filtering, we used an algorithm that calculates absolute eye gaze angle via statistical analysis of detected saccades. The estimated eye positions of the new algorithm were still noisy. However, the performance in terms of Pearson product-moment correlation coefficients was significantly better than the conventional approach in some instances. The results suggest that in-ear EOG signals captured with conductive ear moulds could serve as a basis for light-weight and portable horizontal eye gaze angle estimation suitable for a broad range of applications. For instance, for hearing aids to steer the directivity of microphones in the direction of the user’s eye gaze. PMID:29304120
Shichinohe, Natsuko; Akao, Teppei; Kurkin, Sergei; Fukushima, Junko; Kaneko, Chris R S; Fukushima, Kikuro
2009-06-11
Cortical motor areas are thought to contribute "higher-order processing," but what that processing might include is unknown. Previous studies of the smooth pursuit-related discharge of supplementary eye field (SEF) neurons have not distinguished activity associated with the preparation for pursuit from discharge related to processing or memory of the target motion signals. Using a memory-based task designed to separate these components, we show that the SEF contains signals coding retinal image-slip-velocity, memory, and assessment of visual motion direction, the decision of whether to pursue, and the preparation for pursuit eye movements. Bilateral muscimol injection into SEF resulted in directional errors in smooth pursuit, errors of whether to pursue, and impairment of initial correct eye movements. These results suggest an important role for the SEF in memory and assessment of visual motion direction and the programming of appropriate pursuit eye movements.
Hládek, Ľuboš; Porr, Bernd; Brimijoin, W Owen
2018-01-01
The manuscript proposes and evaluates a real-time algorithm for estimating eye gaze angle based solely on single-channel electrooculography (EOG), which can be obtained directly from the ear canal using conductive ear moulds. In contrast to conventional high-pass filtering, we used an algorithm that calculates absolute eye gaze angle via statistical analysis of detected saccades. The estimated eye positions of the new algorithm were still noisy. However, the performance in terms of Pearson product-moment correlation coefficients was significantly better than the conventional approach in some instances. The results suggest that in-ear EOG signals captured with conductive ear moulds could serve as a basis for light-weight and portable horizontal eye gaze angle estimation suitable for a broad range of applications. For instance, for hearing aids to steer the directivity of microphones in the direction of the user's eye gaze.
Understanding eye movements in face recognition using hidden Markov models.
Chuk, Tim; Chan, Antoni B; Hsiao, Janet H
2014-09-16
We use a hidden Markov model (HMM) based approach to analyze eye movement data in face recognition. HMMs are statistical models that are specialized in handling time-series data. We conducted a face recognition task with Asian participants, and model each participant's eye movement pattern with an HMM, which summarized the participant's scan paths in face recognition with both regions of interest and the transition probabilities among them. By clustering these HMMs, we showed that participants' eye movements could be categorized into holistic or analytic patterns, demonstrating significant individual differences even within the same culture. Participants with the analytic pattern had longer response times, but did not differ significantly in recognition accuracy from those with the holistic pattern. We also found that correct and wrong recognitions were associated with distinctive eye movement patterns; the difference between the two patterns lies in the transitions rather than locations of the fixations alone. © 2014 ARVO.
Cognitive context detection in UAS operators using eye-gaze patterns on computer screens
NASA Astrophysics Data System (ADS)
Mannaru, Pujitha; Balasingam, Balakumar; Pattipati, Krishna; Sibley, Ciara; Coyne, Joseph
2016-05-01
In this paper, we demonstrate the use of eye-gaze metrics of unmanned aerial systems (UAS) operators as effective indices of their cognitive workload. Our analyses are based on an experiment where twenty participants performed pre-scripted UAS missions of three different difficulty levels by interacting with two custom designed graphical user interfaces (GUIs) that are displayed side by side. First, we compute several eye-gaze metrics, traditional eye movement metrics as well as newly proposed ones, and analyze their effectiveness as cognitive classifiers. Most of the eye-gaze metrics are computed by dividing the computer screen into "cells". Then, we perform several analyses in order to select metrics for effective cognitive context classification related to our specific application; the objective of these analyses are to (i) identify appropriate ways to divide the screen into cells; (ii) select appropriate metrics for training and classification of cognitive features; and (iii) identify a suitable classification method.
Dias, Diego Torres; Ushida, Michele; Battistella, Roberto; Dorairaj, Syril; Prata, Tiago Santos
2017-01-10
To analyze the most common neurophthalmological conditions that may mimic glaucomatous optic neuropathy and to determine which most often lead to misdiagnosis when evaluated by a glaucoma specialist. We reviewed the charts of consecutive patients with optic neuropathies caused by neurophthalmological conditions screened in a single Eye Clinic within a period of 24 months. Within these enrolled patients, we selected the eyes whose fundoscopic appearance could resemble glaucoma based in pre-defined criteria (vertical cup-to-disc ratio ≥0.6, asymmetry of the cup-to-disc ratio ≥0.2 between eyes, presence of localized retinal nerve fiber layer and/or neuroretinal rim defects, and disc haemorrhages). Then, color fundus photographs and Humphrey Visual Field tests (HVF) of these eyes were mixed with tests from 21 consecutive glaucomatous patients (42 eyes with normal tension glaucoma). These images were mixed randomly and a masked glaucoma specialist was asked to distinguish if each set of exams was from a patient with glaucoma or with a neurophthalmologic condition. Among the 101 eyes (68 patients) enrolled with neurophthalmological diseases, 16 (15.8%) were classified as conditions that could mimic glaucoma. The most common diagnoses were ischemic optic neuropathy (25%), compressive optic neuropathy (18.7%) and hereditary optic neuropathy (18.7%). Based on the analysis of fundus photographs and HVF tests, 25% of these were misdiagnosed as glaucoma (two ischemic optic neuropathies and two congenital optic disc anomalies). Conversely, 11.9% of the glaucomatous neuropathies were misdiagnosed as neurophthalmological disorders. Overall, the glaucoma specialist correctly diagnosed 84.5% of the eyes. Some neurophthalmological disorders can mimic glaucoma. In our study, isquemic and compressive optic neuropathies were the ones that most often did so. Almost one quarter of the eyes were misdiagnosed when evaluated by a glaucoma specialist, which can lead to inadequate management and influence the prognosis of these patients.
Diabetic eye disease among adults in Fiji with previously undiagnosed diabetes.
Brian, Garry; Sikivou, Biu; Fischer-Harder, Konstanze; Szetu, John; Qoqonokana, Mundi Qalo; Ramke, Jacqueline
2011-01-01
To determine the prevalence and severity of diabetic eye disease among adults aged ≥40 years with unrecognized diabetes in Fiji. Population-based cross-sectional survey using multistage cluster random sampling. 1381 (=73.0% participation). Interview-based questionnaire; visual acuity measured; dilated ocular examination performed; glycosylated haemoglobin (HbA1c) concentration determined. Prevalence and grade of diabetic retinopathy/maculopathy. Sample prevalence of diabetes was 44.8% (95%CI 42.2-47.5%), with 63.4% (95%CI 59.5-67.1%) previously undiagnosed (384/606). Predictors of undiagnosed compared with previously diagnosed diabetes were female gender (P = 0.001), rural residence (P = 0.049) and not having a relative with known diabetes (P < 0.001). Twenty-two retinae of participants with previously undiagnosed diabetes were unexaminable (predominantly cataract). Of the remaining 746 eyes, 3.5% (95%CI 2.4-5.1%) had diabetic retinopathy/maculopathy, 1 (0.1%) had proliferative retinopathy and 4 (0.5%) had active significant maculopathy. Of eyes with diabetic disease, two (7.7%, 95%CI 1.0-25.3%) had diabetes-related vision impairment (3/60; 6/60). Sixteen previously undiagnosed participants (4.2%, 95%CI 2.5-6.7%) had diabetic disease evident in at least one eye: for four (all Melanesian women aged >50 years), this was vision-threatening (1.0%; 95%CI 0.3-2.8). Mean HbA1c (10.7 ± 2.6%) of participants undiagnosed and with diabetes eye disease was higher (P < 0.001) than that of those undiagnosed and without. The prevalence of diabetic eye disease was low among this cohort, but where present, severe vision-threatening retinopathy/maculopathy was relatively common. If diabetic eye disease is to be avoided or ameliorated in Fiji, then community awareness of and access to diabetes diagnostic services must improve, particularly for women and rural dwellers. © 2011 The Authors. Clinical and Experimental Ophthalmology © 2011 Royal Australian and New Zealand College of Ophthalmologists.
Effect of glaucoma on eye movement patterns and laboratory-based hazard detection ability
Black, Alex A.; Wood, Joanne M.
2017-01-01
Purpose The mechanisms underlying the elevated crash rates of older drivers with glaucoma are poorly understood. A key driving skill is timely detection of hazards; however, the hazard detection ability of drivers with glaucoma has been largely unexplored. This study assessed the eye movement patterns and visual predictors of performance on a laboratory-based hazard detection task in older drivers with glaucoma. Methods Participants included 30 older drivers with glaucoma (71±7 years; average better-eye mean deviation (MD) = −3.1±3.2 dB; average worse-eye MD = −11.9±6.2 dB) and 25 age-matched controls (72±7 years). Visual acuity, contrast sensitivity, visual fields, useful field of view (UFoV; processing speeds), and motion sensitivity were assessed. Participants completed a computerised Hazard Perception Test (HPT) while their eye movements were recorded using a desk-mounted Tobii TX300 eye-tracking system. The HPT comprises a series of real-world traffic videos recorded from the driver’s perspective; participants responded to road hazards appearing in the videos, and hazard response times were determined. Results Participants with glaucoma exhibited an average of 0.42 seconds delay in hazard response time (p = 0.001), smaller saccades (p = 0.010), and delayed first fixation on hazards (p<0.001) compared to controls. Importantly, larger saccades were associated with faster hazard responses in the glaucoma group (p = 0.004), but not in the control group (p = 0.19). Across both groups, significant visual predictors of hazard response times included motion sensitivity, UFoV, and worse-eye MD (p<0.05). Conclusions Older drivers with glaucoma had delayed hazard response times compared to controls, with associated changes in eye movement patterns. The association between larger saccades and faster hazard response time in the glaucoma group may represent a compensatory behaviour to facilitate improved performance. PMID:28570621
Ventura, Bruna V; Wang, Li; Ali, Shazia F; Koch, Douglas D; Weikert, Mitchell P
2015-08-01
To evaluate and compare the performance of a point-source color light-emitting diode (LED)-based topographer (color-LED) in measuring anterior corneal power and aberrations with that of a Placido-disk topographer and a combined Placido and dual Scheimpflug device. Cullen Eye Institute, Baylor College of Medicine, Houston, Texas USA. Retrospective observational case series. Normal eyes and post-refractive-surgery eyes were consecutively measured using color-LED, Placido, and dual-Scheimpflug devices. The main outcome measures were anterior corneal power, astigmatism, and higher-order aberrations (HOAs) (6.0 mm pupil), which were compared using the t test. There were no statistically significant differences in corneal power measurements in normal and post-refractive surgery eyes and in astigmatism magnitude in post-refractive surgery eyes between the color-LED device and Placido or dual Scheimpflug devices (all P > .05). In normal eyes, there were no statistically significant differences in 3rd-order coma and 4th-order spherical aberration between the color-LED and Placido devices and in HOA root mean square, 3rd-order coma, 3rd-order trefoil, 4th-order spherical aberration, and 4th-order secondary astigmatism between the color-LED and dual Scheimpflug devices (all P > .05). In post-refractive surgery eyes, the color-LED device agreed with the Placido and dual-Scheimpflug devices regarding 3rd-order coma and 4th-order spherical aberration (all P > .05). In normal and post-refractive surgery eyes, all 3 devices were comparable with respect to corneal power. The agreement in corneal aberrations varied. Drs. Wang, Koch, and Weikert are consultants to Ziemer Ophthalmic Systems AG. Dr. Koch is a consultant to Abbott Medical Optics, Inc., Alcon Surgical, Inc., and i-Optics Corp. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Identification of the optic nerve head with genetic algorithms.
Carmona, Enrique J; Rincón, Mariano; García-Feijoó, Julián; Martínez-de-la-Casa, José M
2008-07-01
This work proposes creating an automatic system to locate and segment the optic nerve head (ONH) in eye fundus photographic images using genetic algorithms. Domain knowledge is used to create a set of heuristics that guide the various steps involved in the process. Initially, using an eye fundus colour image as input, a set of hypothesis points was obtained that exhibited geometric properties and intensity levels similar to the ONH contour pixels. Next, a genetic algorithm was used to find an ellipse containing the maximum number of hypothesis points in an offset of its perimeter, considering some constraints. The ellipse thus obtained is the approximation to the ONH. The segmentation method is tested in a sample of 110 eye fundus images, belonging to 55 patients with glaucoma (23.1%) and eye hypertension (76.9%) and random selected from an eye fundus image base belonging to the Ophthalmology Service at Miguel Servet Hospital, Saragossa (Spain). The results obtained are competitive with those in the literature. The method's generalization capability is reinforced when it is applied to a different image base from the one used in our study and a discrepancy curve is obtained very similar to the one obtained in our image base. In addition, the robustness of the method proposed can be seen in the high percentage of images obtained with a discrepancy delta<5 (96% and 99% in our and a different image base, respectively). The results also confirm the hypothesis that the ONH contour can be properly approached with a non-deformable ellipse. Another important aspect of the method is that it directly provides the parameters characterising the shape of the papilla: lengths of its major and minor axes, its centre of location and its orientation with regard to the horizontal position.
Waisbourd, Michael; Dhami, Hermandeep; Zhou, Chen; Hsieh, Michael; Abichandani, Pramod; Pro, Michael J; Moster, Marlene R; Katz, L Jay; Hark, Lisa A; Myers, Jonathan S
2016-09-01
To evaluate the interest of glaucoma patients and their caregivers in a smartphone-based and tablet-based glaucoma application (App), developed by the Wills Eye Glaucoma Research Center in collaboration with Drexel University. Cross-sectional survey of patients with glaucoma and their caregivers. Main outcome measures are answers to survey questions regarding how receptive participants are to using the Glaucoma App. Fifty subjects completed the survey. The mean age (SD) was 59.5 (±17.3) years. A total of 88.6% of the participants lived in a household with access to a smartphone or tablet. The majority (72.3%) of participants would consider downloading the Glaucoma App, and younger participants (<65 y) were more likely to do so compared with their older (≥65 y) counterparts, P=0.025. Participants were more likely to download the App if it was free of charge, compared with a version that costs $3, P=0.018. Although only about one third (37.8%) of participants used eye drop reminders, nearly 3 of 4 (72.9%) participants were receptive to using the automated reminder feature of the Glaucoma App. Glaucoma patients and their caregivers were very interested in using a Glaucoma App; however, many were not willing to spend $3 for an App they seem to value. The free Wills Eye Glaucoma App currently available on the Apple store, includes educational videos, eye drop and appointment reminders, medical and ocular data storage, visual field tutorial, and intraocular pressure tracker. These features aim to increase patients' level of knowledge about glaucoma and improve their adherence to medication and follow-up appointment recommendations.
Method of preliminary localization of the iris in biometric access control systems
NASA Astrophysics Data System (ADS)
Minacova, N.; Petrov, I.
2015-10-01
This paper presents a method of preliminary localization of the iris, based on the stable brightness features of the iris in images of the eye. In tests on images of eyes from publicly available databases method showed good accuracy and speed compared to existing methods preliminary localization.
Using Eye Movement Desensitization and Reprocessing To Enhance Treatment of Couples.
ERIC Educational Resources Information Center
Protinsky, Howard; Sparks, Jennifer; Flemke, Kimberly
2001-01-01
Eye Movement Desensitization and Reprocessing (EMDR) as a clinical technique may enhance treatment effectiveness when applied in couple therapy that is emotionally and experientially oriented. Clinical experience indicates EMDR-based interventions are useful for accessing and reprocessing intense emotions in couple interactions. EMDR can amplify…
Red eyes and red-flags: improving ophthalmic assessment and referral in primary care
Kilduff, Caroline; Lois, Charis
2016-01-01
Up to five percent of primary care consultations are eye-related, yet 96% of General Practitioners (GPs) do not undergo postgraduate ophthalmology training. Most do not feel assured performing eye assessments. Some red eye conditions can become sight threatening, and often exhibit red-flag features. These features include moderate pain, photophobia, reduced visual acuity (VA), eye-trauma, or unilateral marked redness. The aim of this project was to improve primary care assessment and referral of patients presenting with red-flag features based on the NICE ‘Red Eye’ Clinical Knowledge Summary recommendations. Data was collected retrospectively from 139 red eye consultations. A practice meeting highlighted poor awareness of red-flag features, low confidence levels in eye assessments, and time-constraints during appointments. Interventions were based on feedback from staff. These included a primary care teaching session on red-flag features, a VA measurement tutorial, and provision of a red eye toolkit, including VA equipment, to each consultation room. At baseline, each patient had on average 0.9 red-flag features assessed. Only 36.0% (9/25) of patients with red-flag features were appropriately referred to same-day ophthalmology services. Following two improvement cycles, a significant improvement was seen in almost every parameter. On average, each patient had 2.7 red-flag features assessed (vs 0.9, p<0.001). VA was assessed in 55.6% of consultations (vs 7.9%, p<0.001), pain was quantified in 81.5% (vs 20.9%, p=0.005), eye-trauma or foreign-body (51.8% vs 8.6%, p<0.001), extent of redness was documented in 66.7% (vs 14.4%, p<0.001). Only photophobia remained poorly assessed (18.5% vs 14.4%, p=0.75). Following this, 75.0% (6/8) of patients were appropriately referred. This project reflected the literature regarding low confidence and inexperience amongst GPs when faced with ophthalmic conditions. Improvements in education are required to ensure accurate assessments can be undertaken in a time-constrained environment. PMID:27493748
da Silva, Artur Christian Garcia; Chialchia, Adrienny Rodrigues; de Ávila, Renato Ivan; Valadares, Marize Campos
2018-06-25
Eye toxicity is a mandatory parameter in human risk and safety evaluation for products including chemicals, pesticides, medicines and cosmetics. Historically, this endpoint has been evaluated using the Draize rabbit eye test, an in vivo model that was never formally validated. Due to advances in scientific knowledge, economic and ethical issues, non-animal methods based on mechanisms of toxicity are being developed and validated for increasing the capability of these models to predict eye toxicity. In this study, the Cytometric Bead Array (CBA) and ELISA assays were used to evaluate the inflammatory cytokine profile produced by HaCaT human keratinocytes after exposure to chemicals with different UN GHS eye toxicity classifications, aiming to stablish a correlation between inflammatory endpoints and eye toxicity (damage/irritation) potential. As a first step, cytotoxic profile of the chemicals, including 3 non-irritants and 10 eye toxicants (GHS Category 1, 2A and 2B), was evaluated after 24 h exposure using MTT assay and Inhibitory Concentration of 20% of cell viability (IC 20 ) was calculated for each chemical. Then, the cells were exposed to these chemicals at IC 20 for 24 h and supernatants and cell lysates were analyzed by CBA assay for quantification of the following cytokines: IL-6, IL-8, IL-10, IL-1β, TNF and IL-12p70. Regarding cytotoxicity evaluation, chemicals showed different cytotoxicity profiles and data demonstrated no correlation with their UN GHS classification. Among the cytokines evaluated, IL-1β production has changed after exposure and such alterations were confirmed by quantification employing ELISA method. The higher intracellular levels of IL-1β were found in GHS Category 1 chemicals, followed by Category 2A and 2B, while non irritants did not induce such increase. Thus, these findings show that IL-1β measurement, using HaCaT model, can be a considerable biomarker to identify chemicals according to their potential in promote eye toxicity, differentiating damage from irritation potential. Copyright © 2018. Published by Elsevier B.V.
Palmer, Jennifer J; Gilbert, Alice; Choy, Michelle; Blanchet, Karl
2016-09-09
Little is known about the contributions of faith-based organisations (FBOs) to health systems in Africa. In the specialist area of eye health, international and domestic Christian FBOs have been important contributors as service providers and donors, but they are also commonly critiqued as having developed eye health systems parallel to government structures which are unsustainable. In this study, we use a health systems approach (quarterly interviews, a participatory sustainability analysis exercise and a social network analysis) to describe the strategies used by eye care practitioners in four hospitals of north-west Tanzania to navigate the government, church mission and donor rules that govern eye services delivery there. Practitioners in this region felt eye care was systemically neglected by government and therefore was 'all under the NGOs', but support from international donors was also precarious. Practitioners therefore adopted four main strategies to improve the sustainability of their services: (1) maintain 'sustainability funds' to retain financial autonomy over income; (2) avoid granting government user fee exemptions to elderly patients who are the majority of service users; (3) expand or contract outreach services as financial circumstances change; and (4) access peer support for problem-solving and advocacy. Mission-based eye teams had greater freedom to increase their income from user fees by not implementing government policies for 'free care'. Teams in all hospitals, however, found similar strategies to manage their programmes even when their management structures were unique, suggesting the importance of informal rules shared through a peer network in governing eye care in this pluralistic health system. Health systems research can generate new evidence on the social dynamics that cross public and private sectors within a local health system. In this area of Tanzania, Christian FBOs' investments are important, not only in terms of the population health outcomes achieved by teams they support, but also in the diversity of organisational models they contribute to in the wider eye health system, which facilitates innovation.
Quality indicators for eye bank.
Acharya, Manisha; Biswas, Saurabh; Das, Animesh; Mathur, Umang; Dave, Abhishek; Singh, Ashok; Dubey, Suneeta
2018-03-01
The aim of this study is to identify quality indicators of the eye bank and validate their effectivity. Adverse reaction rate, discard rate, protocol deviation rate, and compliance rate were defined as Quality Indicators of the eye bank. These were identified based on definition of quality that captures two dimensions - "result quality" and "process quality." The indicators were measured and tracked as part of quality assurance (QA) program of the eye bank. Regular audits were performed to validate alignment of standard operating procedures (SOP) with regulatory and surgeon acceptance standards and alignment of activities performed in the eye bank with the SOP. Prospective study of the indicators was performed by comparing their observed values over the period 2011-2016. Adverse reaction rate decreased more than 8-fold (from 0.61% to 0.07%), discard rate decreased and stabilized at 30%, protocol deviation rate decreased from 1.05% to 0.08%, and compliance rate reported by annual quality audits improved from 59% to 96% at the same time. In effect, adverse reaction rate, discard rate, and protocol deviation rate were leading indicators, and compliance rate was the trailing indicator. These indicators fulfill an important gap in available literature on QA in eye banking. There are two ways in which these findings can be meaningful. First, eye banks which are new to quality measurement can adopt these indicators. Second, eye banks which are already deeply engaged in quality improvement can test these indicators in their eye bank, thereby incorporating them widely and improving them over time.
NASA Astrophysics Data System (ADS)
Irsch, Kristina; Gramatikov, Boris I.; Wu, Yi-Kai; Guyton, David L.
2014-06-01
Amblyopia ("lazy eye") is a major public health problem, caused by misalignment of the eyes (strabismus) or defocus. If detected early in childhood, there is an excellent response to therapy, yet most children are detected too late to be treated effectively. Commercially available vision screening devices that test for amblyopia's primary causes can detect strabismus only indirectly and inaccurately via assessment of the positions of external light reflections from the cornea, but they cannot detect the anatomical feature of the eyes where fixation actually occurs (the fovea). Our laboratory has been developing technology to detect true foveal fixation, by exploiting the birefringence of the uniquely arranged Henle fibers delineating the fovea using retinal birefringence scanning (RBS), and we recently described a polarization-modulated approach to RBS that enables entirely direct and reliable detection of true foveal fixation, with greatly enhanced signal-to-noise ratio and essentially independent of corneal birefringence (a confounding variable with all polarization-sensitive ophthalmic technology). Here, we describe the design and operation of a new pediatric vision screener that employs polarization-modulated, RBS-based strabismus detection and bull's eye focus detection with an improved target system, and demonstrate the feasibility of this new approach.
[Keratoconus special soft contact lens fitting].
Yamazaki, Ester Sakae; da Silva, Vanessa Cristina Batista; Morimitsu, Vagner; Sobrinho, Marcelo; Fukushima, Nelson; Lipener, César
2006-01-01
To evaluate the fitting and use of a soft contact lens in keratoconic patients. Retrospective study on 80 eyes of 66 patients, fitted with a special soft contact lens for keratoconus, at the Contact Lens Section of UNIFESP and private clinics. Keratoconus was classified according to degrees of disease severity by keratometric pattern. Age, gender, diagnosis, keratometry, visual acuity, spherical equivalent (SE), base curve and clinical indication were recorded. Of 66 patients (80 eyes) with keratoconus the mean age was 29 years, 51.5% were men and 48.5% women. According to the groups: 15.0% were incipient, 53.7% moderate, 26.3% advanced and 5.0% were severe. The majority of the eyes of patients using contact lenses (91.25%) achieved visual acuity better than 20/40. To 88 eyes 58% were tihed with lens with spherical power (mean -5.45 diopters) and 41% with spherocylinder power (from -0.5 to -5.00 cylindrical diopters). The most frequent base curve was 7.6 in 61% of the eyes. The main reasons for this special lens fitting were due to reduced tolerance and poor fitting pattern achieved with other lenses. The special soft contact lens is useful in fitting difficult keratoconic patients by offering comfort and improving visual rehabilitation that may allow more patients to postpone the need for corneal transplant.
Irsch, Kristina; Gramatikov, Boris I; Wu, Yi-Kai; Guyton, David L
2014-06-01
Amblyopia ("lazy eye") is a major public health problem, caused by misalignment of the eyes (strabismus) or defocus. If detected early in childhood, there is an excellent response to therapy, yet most children are detected too late to be treated effectively. Commercially available vision screening devices that test for amblyopia's primary causes can detect strabismus only indirectly and inaccurately via assessment of the positions of external light reflections from the cornea, but they cannot detect the anatomical feature of the eyes where fixation actually occurs (the fovea). Our laboratory has been developing technology to detect true foveal fixation, by exploiting the birefringence of the uniquely arranged Henle fibers delineating the fovea using retinal birefringence scanning (RBS), and we recently described a polarization-modulated approach to RBS that enables entirely direct and reliable detection of true foveal fixation, with greatly enhanced signal-to-noise ratio and essentially independent of corneal birefringence (a confounding variable with all polarization-sensitive ophthalmic technology). Here, we describe the design and operation of a new pediatric vision screener that employs polarization-modulated, RBS-based strabismus detection and bull's eye focus detection with an improved target system, and demonstrate the feasibility of this new approach.
Furdová, Alena; Sramka, Miron; Thurzo, Andrej; Furdová, Adriana
2017-01-01
Objective The objective of this study was to determine the use of 3D printed model of an eye with intraocular tumor for linear accelerator-based stereotactic radiosurgery. Methods The software for segmentation (3D Slicer) created virtual 3D model of eye globe with tumorous mass based on tissue density from computed tomography and magnetic resonance imaging data. A virtual model was then processed in the slicing software (Simplify3D®) and printed on 3D printer using fused deposition modeling technology. The material that was used for printing was polylactic acid. Results In 2015, stereotactic planning scheme was optimized with the help of 3D printed model of the patient’s eye with intraocular tumor. In the period 2001–2015, a group of 150 patients with uveal melanoma (139 choroidal melanoma and 11 ciliary body melanoma) were treated. The median tumor volume was 0.5 cm3 (0.2–1.6 cm3). The radiation dose was 35.0 Gy by 99% of dose volume histogram. Conclusion The 3D printed model of eye with tumor was helpful in planning the process to achieve the optimal scheme for irradiation which requires high accuracy of defining the targeted tumor mass and critical structures. PMID:28203052
An ancient explanation of presbyopia based on binocular vision.
Barbero, Sergio
2014-06-01
Presbyopia, understood as the age-related loss of ability to clearly see near objects, was known to ancient Greeks. However, few references to it can be found in ancient manuscripts. A relevant discussion on presbyopia appears in a book called Symposiacs written by Lucius Mestrius Plutarchus around 100 A.C. In this work, Plutarch provided four explanations of presbyopia, associated with different theories of vision. One of the explanations is particularly interesting as it is based on a binocular theory of vision. In this theory, vision is produced when visual rays, emanating from the eyes, form visual cones that impinge on the objects to be seen. Visual rays coming from old people's eyes, it was supposed, are weaker than those from younger people's eyes; so the theory, to be logically coherent, implies that this effect is compensated by the increase in light intensity due to the overlapping, at a certain distance, of the visual cones coming from both eyes. Thus, it benefits the reader to move the reading text further away from the eyes in order to increase the fusion area of both visual cones. The historical hypothesis taking into consideration that the astronomer Hipparchus of Nicaea was the source of Plutarch's explanation of the theory is discussed. © 2013 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Modelling eye movements in a categorical search task
Zelinsky, Gregory J.; Adeli, Hossein; Peng, Yifan; Samaras, Dimitris
2013-01-01
We introduce a model of eye movements during categorical search, the task of finding and recognizing categorically defined targets. It extends a previous model of eye movements during search (target acquisition model, TAM) by using distances from an support vector machine classification boundary to create probability maps indicating pixel-by-pixel evidence for the target category in search images. Other additions include functionality enabling target-absent searches, and a fixation-based blurring of the search images now based on a mapping between visual and collicular space. We tested this model on images from a previously conducted variable set-size (6/13/20) present/absent search experiment where participants searched for categorically defined teddy bear targets among random category distractors. The model not only captured target-present/absent set-size effects, but also accurately predicted for all conditions the numbers of fixations made prior to search judgements. It also predicted the percentages of first eye movements during search landing on targets, a conservative measure of search guidance. Effects of set size on false negative and false positive errors were also captured, but error rates in general were overestimated. We conclude that visual features discriminating a target category from non-targets can be learned and used to guide eye movements during categorical search. PMID:24018720
Bielecki, Jan; Zaharoff, Alexander K; Leung, Nicole Y; Garm, Anders; Oakley, Todd H
2014-01-01
A growing body of work on the neuroethology of cubozoans is based largely on the capabilities of the photoreceptive tissues, and it is important to determine the molecular basis of their light sensitivity. The cubozoans rely on 24 special purpose eyes to extract specific information from a complex visual scene to guide their behavior in the habitat. The lens eyes are the most studied photoreceptive structures, and the phototransduction in the photoreceptor cells is based on light sensitive opsin molecules. Opsins are photosensitive transmembrane proteins associated with photoreceptors in eyes, and the amino acid sequence of the opsins determines the spectral properties of the photoreceptors. Here we show that two distinct opsins (Tripedalia cystophora-lens eye expressed opsin and Tripedalia cystophora-neuropil expressed opsin, or Tc-leo and Tc-neo) are expressed in the Tripedalia cystophora rhopalium. Quantitative PCR determined the level of expression of the two opsins, and we found Tc-leo to have a higher amount of expression than Tc-neo. In situ hybridization located Tc-leo expression in the retinal photoreceptors of the lens eyes where the opsin is involved in image formation. Tc-neo is expressed in a confined part of the neuropil and is probably involved in extraocular light sensation, presumably in relation to diurnal activity.
The Chinese American Eye Study: Design and Methods
Varma, Rohit; Hsu, Chunyi; Wang, Dandan; Torres, Mina; Azen, Stanley P.
2016-01-01
Purpose To summarize the study design, operational strategies and procedures of the Chinese American Eye Study (CHES), a population-based assessment of the prevalence of visual impairment, ocular disease, and visual functioning in Chinese Americans. Methods This population-based, cross-sectional study, included 4,570 Chinese, 50 years and older, residing in the city of Monterey Park, California. Each eligible participant completed a detailed interview and eye examination. The interview included an assessment of demographic, behavioral, and ocular risk factors and health-related and vision-related quality of life. The eye examination included measurements of visual acuity, intraocular pressure, visual fields, fundus and optic disc photography, a detailed anterior and posterior segment examination, and measurements of blood pressure, glycosylated hemoglobin levels, and blood glucose levels. Results The objectives of the CHES are to obtain prevalence estimates of visual impairment, refractive error, diabetic retinopathy, open-angle and angle-closure glaucoma, lens opacities, and age-related macular degeneration in Chinese-Americans. In addition, outcomes include effect estimates for risk factors associated with eye diseases. Lastly, CHES will investigate the genetic determinates of myopia and glaucoma. Conclusion The CHES will provide information about the prevalence and risk factors of ocular diseases in one of the fastest growing minority groups in the United States. PMID:24044409
Atmospheric effects on laser eye safety and damage to instrumentation
NASA Astrophysics Data System (ADS)
Zilberman, Arkadi; Kopeika, Natan S.
2017-10-01
Electro-optical sensors as well as unprotected human eyes are extremely sensitive to laser radiation and can be permanently damaged from direct or reflected beams. Laser detector/eye hazard depends on the interaction between the laser beam and the media in which it traverses. The environmental conditions including terrain features, atmospheric particulate and water content, and turbulence, may alter the laser's effect on the detector/eye. It is possible to estimate the performance of an electro-optical system as long as the atmospheric propagation of the laser beam can be adequately modeled. More recent experiments and modeling of atmospheric optics phenomena such as inner scale effect, aperture averaging, atmospheric attenuation in NIR-SWIR, and Cn2 modeling justify an update of previous eye/detector safety modeling. In the present work, the influence of the atmospheric channel on laser safety for personnel and instrumentation is shown on the basis of theoretical and experimental data of laser irradiance statistics for different atmospheric conditions. A method for evaluating the probability of damage and hazard distances associated with the use of laser systems in a turbulent atmosphere operating in the visible and NIR-SWIR portions of the electromagnetic spectrum is presented. It can be used as a performance prediction model for directed energy engagement of ground-based or air-based systems.
Olson, Jeffrey L; Velez-Montoya, Raul; Mandava, Naresh; Stoldt, Conrad R
2012-08-17
To study the intravitreal application of silicon quantum dots (QDs) and their capabilities to deliver electrical stimulation to the retinal cells and to assess the potential effect on retinal electrophysiology and anatomy. A Royal College of Surgeon rat model of retinal degeneration was used in this study. A total of 32 eyes were used, divided in four groups of 8 eyes each; the first group received the silicon-based QD, the second group received an inactive gold-based QD, the third group received a sham injection, and the fourth group was used as a control. An electroretinogram (ERG) was done at baseline and thereafter every week for 9 weeks. At the end of the follow-up, eyes were collected for further pathologic analysis and nuclei cell counts. Eyes within the silicon-based QD group showed a definite but transient increase in the waves of the ERG, especially in the rod response compared with the sham and control groups (P < 0.05). The pathologic examination demonstrated a higher nuclei count in the QD group, consistent with a higher cell survival rate than that in the sham and control groups in which cells degenerated as expected. Intravitreal injection of silicon-based QD seems to be safe and well tolerated, with no evident toxic reaction and demonstrates a beneficial effect by prolonging cell survival rate and improving ERG patterns in a well-established model of retinal degeneration. (ClinicalTrials.gov numbers NCT00407602, NCT01490827.).
Harrison, Charlotte; Jackson, Jade; Oh, Seung-Mock; Zeringyte, Vaida
2016-01-01
Multivariate pattern analysis of functional magnetic resonance imaging (fMRI) data is widely used, yet the spatial scales and origin of neurovascular signals underlying such analyses remain unclear. We compared decoding performance for stimulus orientation and eye of origin from fMRI measurements in human visual cortex with predictions based on the columnar organization of each feature and estimated the spatial scales of patterns driving decoding. Both orientation and eye of origin could be decoded significantly above chance in early visual areas (V1–V3). Contrary to predictions based on a columnar origin of response biases, decoding performance for eye of origin in V2 and V3 was not significantly lower than that in V1, nor did decoding performance for orientation and eye of origin differ significantly. Instead, response biases for both features showed large-scale organization, evident as a radial bias for orientation, and a nasotemporal bias for eye preference. To determine whether these patterns could drive classification, we quantified the effect on classification performance of binning voxels according to visual field position. Consistent with large-scale biases driving classification, binning by polar angle yielded significantly better decoding performance for orientation than random binning in V1–V3. Similarly, binning by hemifield significantly improved decoding performance for eye of origin. Patterns of orientation and eye preference bias in V2 and V3 showed a substantial degree of spatial correlation with the corresponding patterns in V1, suggesting that response biases in these areas originate in V1. Together, these findings indicate that multivariate classification results need not reflect the underlying columnar organization of neuronal response selectivities in early visual areas. NEW & NOTEWORTHY Large-scale response biases can account for decoding of orientation and eye of origin in human early visual areas V1–V3. For eye of origin this pattern is a nasotemporal bias; for orientation it is a radial bias. Differences in decoding performance across areas and stimulus features are not well predicted by differences in columnar-scale organization of each feature. Large-scale biases in extrastriate areas are spatially correlated with those in V1, suggesting biases originate in primary visual cortex. PMID:27903637
Speiser, Daniel I.; Gagnon, Yakir Luc; Chhetri, Raghav K.; Oldenburg, Amy L.; Johnsen, Sönke
2016-01-01
The eyes of scallops form images using a concave spherical mirror and contain two separate retinas, one layered on top of the other. Behavioral and electrophysiological studies indicate that the images formed by these eyes have angular resolutions of about 2°. Based on previous ray-tracing models, it has been thought that the more distal of the two retinas lies near the focal point of the mirror and that the proximal retina, positioned closer to the mirror at the back of the eye, receives light that is out-of-focus. Here, we propose three mechanisms through which both retinas may receive focused light: (1) chromatic aberration produced by the lens may cause the focal points for longer and shorter wavelengths to fall near the distal and proximal retinas, respectively; (2) focused light from near and far objects may fall on the distal and proximal retinas, respectively; and (3) the eyes of scallops may be dynamic structures that change shape to determine which retina receives focused light. To test our hypotheses, we used optical coherence tomography (OCT), a method of near-infrared optical depth-ranging, to acquire virtual cross-sections of live, intact eyes from the bay scallop Argopecten irradians. Next, we used a custom-built ray-tracing model to estimate the qualities of the images that fall on an eye’s distal and proximal retinas as functions of the wavelengths of light entering the eye (400–700 nm), object distances (0.01–1 m), and the overall shape of the eye. When we assume 550 nm wavelength light and object distances greater than 0.01 m, our model predicts that the angular resolutions of the distal and proximal retinas are 2° and 7°, respectively. Our model also predicts that neither chromatic aberration nor differences in object distance lead to focused light falling on the distal and proximal retinas simultaneously. However, if scallops can manipulate the shapes of their eyes, perhaps through muscle contractions, we speculate that they may be able to influence the qualities of the images that fall on their proximal retinas and—to a lesser extent—those that fall on their distal retinas as well. PMID:27549200
Design of retinal-projection-based near-eye display with contact lens.
Wu, Yuhang; Chen, Chao Ping; Mi, Lantian; Zhang, Wenbo; Zhao, Jingxin; Lu, Yifan; Guo, Weiqian; Yu, Bing; Li, Yang; Maitlo, Nizamuddin
2018-04-30
We propose a design of a retinal-projection-based near-eye display for achieving ultra-large field of view, vision correction, and occlusion. Our solution is highlighted by a contact lens combo, a transparent organic light-emitting diode panel, and a twisted nematic liquid crystal panel. Its design rules are set forth in detail, followed by the results and discussion regarding the field of view, angular resolution, modulation transfer function, contrast ratio, distortion, and simulated imaging.
[Optimization of end-tool parameters based on robot hand-eye calibration].
Zhang, Lilong; Cao, Tong; Liu, Da
2017-04-01
A new one-time registration method was developed in this research for hand-eye calibration of a surgical robot to simplify the operation process and reduce the preparation time. And a new and practical method is introduced in this research to optimize the end-tool parameters of the surgical robot based on analysis of the error sources in this registration method. In the process with one-time registration method, firstly a marker on the end-tool of the robot was recognized by a fixed binocular camera, and then the orientation and position of the marker were calculated based on the joint parameters of the robot. Secondly the relationship between the camera coordinate system and the robot base coordinate system could be established to complete the hand-eye calibration. Because of manufacturing and assembly errors of robot end-tool, an error equation was established with the transformation matrix between the robot end coordinate system and the robot end-tool coordinate system as the variable. Numerical optimization was employed to optimize end-tool parameters of the robot. The experimental results showed that the one-time registration method could significantly improve the efficiency of the robot hand-eye calibration compared with the existing methods. The parameter optimization method could significantly improve the absolute positioning accuracy of the one-time registration method. The absolute positioning accuracy of the one-time registration method can meet the requirements of the clinical surgery.
Dose conversion coefficients for neutron exposure to the lens of the human eye
DOE Office of Scientific and Technical Information (OSTI.GOV)
Manger, Ryan P; Bellamy, Michael B; Eckerman, Keith F
Dose conversion coefficients for the lens of the human eye have been calculated for neutron exposure at energies from 1 x 10{sup -9} to 20 MeV and several standard orientations: anterior-to-posterior, rotational and right lateral. MCNPX version 2.6.0, a Monte Carlo-based particle transport package, was used to determine the energy deposited in the lens of the eye. The human eyeball model was updated by partitioning the lens into sensitive and insensitive volumes as the anterior portion (sensitive volume) of the lens being more radiosensitive and prone to cataract formation. The updated eye model was used with the adult UF-ORNL mathematicalmore » phantom in the MCNPX transport calculations.« less
Autoimmunity in the pathogenesis and treatment of keratoconjunctivitis sicca.
Liu, Katy C; Huynh, Kyle; Grubbs, Joseph; Davis, Richard M
2014-01-01
Dry eye is a chronic corneal disease that impacts the quality of life of many older adults. Keratoconjunctivitis sicca (KCS), a form of aqueous-deficient dry eye, is frequently associated with Sjögren's syndrome and mechanisms of autoimmunity. For KCS and other forms of dry eye, current treatments are limited, with many medications providing only symptomatic relief rather than targeting the pathophysiology of disease. Here, we review proposed mechanisms in the pathogenesis of autoimmune-based KCS: genetic susceptibility and disruptions in antigen recognition, immune response, and immune regulation. By understanding the mechanisms of immune dysfunction through basic science and translational research, potential drug targets can be identified. Finally, we discuss current dry eye therapies as well as promising new treatment options and drug therapy targets.
Fracture Analyses of Cracked Delta Eye Plates in Ship Towing
NASA Astrophysics Data System (ADS)
Huang, Xiangbing; Huang, Xingling; Sun, Jizheng
2018-01-01
Based on fracture mechanics, a safety analysis approach is proposed for cracked delta eye plates in ship towing. The static analysis model is presented when the delta eye plate is in service, and the fracture criterion is introduced on basis of stress intensity factor, which is estimated with domain integral method. Subsequently, three-dimensional finite element analyses are carried out to obtain the effective stress intensity factors, and a case is studied to demonstrate the reasonability of the approach. The results show that the classical strength theory is not applicable to evaluate the cracked plate while fracture mechanics can solve the problem very well, and the load level, which a delta eye plate can carry on, decreases evidently when it is damaged.
Yamada, Akira; Terakawa, Mitsuhiro
2015-04-10
We present a design method of a bull's eye structure with asymmetric grooves for focusing oblique incident light. The design method is capable of designing transmission peaks to a desired oblique angle with capability of collecting light from a wider range of angles. The bull's eye groove geometry for oblique incidence is designed based on the electric field intensity pattern around an isolated subwavelength aperture on a thin gold film at oblique incidence, calculated by the finite difference time domain method. Wide angular transmission efficiency is successfully achieved by overlapping two different bull's eye groove patterns designed with different peak angles. Our novel design method would overcome the angular limitations of the conventional methods.
Application of a wide-field phantom eye for optical coherence tomography and reflectance imaging.
Corcoran, Anthony; Muyo, Gonzalo; van Hemert, Jano; Gorman, Alistair; Harvey, Andrew R
2015-12-15
Optical coherence tomography (OCT) and reflectance imaging are used in clinical practice to measure the thickness and transverse dimensions of retinal features. The recent trend towards increasing the field of view (FOV) of these devices has led to an increasing significance of the optical aberrations of both the human eye and the device. We report the design, manufacture and application of the first phantom eye that reproduces the off-axis optical characteristics of the human eye, and allows the performance assessment of wide-field ophthalmic devices. We base our design and manufacture on the wide-field schematic eye, [Navarro, R. J. Opt. Soc. Am. A , 1985, 2 .] as an accurate proxy to the human eye and enable assessment of ophthalmic imaging performance for a [Formula: see text] external FOV. We used multi-material 3D-printed retinal targets to assess imaging performance of the following ophthalmic instruments: the Optos 200Tx, Heidelberg Spectralis, Zeiss FF4 fundus camera and Optos OCT SLO and use the phantom to provide an insight into some of the challenges of wide-field OCT.
NASA Astrophysics Data System (ADS)
Cui, Zhe; Wang, Anting; Ma, Qianli; Ming, Hai
2013-12-01
In this paper, the laser speckle pattern on human retina for a laser projection display is simulated. By introducing a specific eye model `Indiana Eye', the statistical properties of the laser speckle are numerical investigated. The results show that the aberrations of human eye (mostly spherical and chromatic) will decrease the speckle contrast felt by people. When the wavelength of the laser source is 550 nm (green), people will feel the strongest speck pattern and the weakest when the wavelength is 450 nm (blue). Myopia and hyperopia will decrease the speckle contrast by introducing large spherical aberrations. Although aberration is good for speckle reduction, but it will degrade the imaging capability of the eye. The results show that laser source (650 nm) will have the best image quality on the retina. At last, we compare the human eye with an aberration-free imaging system. Both the speckle contrast and the image quality appear different behavior in these two imaging systems. The results are useful when a standardized measurement procedure for speckle contrast needs to be built.
Ikarashi, Y; Tsuchiya, T; Nakamura, A
1997-01-01
Cytotoxicity potential of chemicals was evaluated by determining the concentrations inducing 50% reduction of neutral red (NR) uptake into Chinese hamster fibroblast V79 cells compared with control culture (IC50). The results of cytotoxicity test for surfactants with the data produced by the in vivo Draize eye and skin irritation test were compared. There was a good correlation between cytotoxicity and eye irritation score obtained from the Draize test. In contrast, no correlation was observed between Draize skin irritation score and cytotoxic potential of chemicals. Therefore, the NR cytotoxicity test was regarded as a possible in vitro model for predicting eye irritation. Based on the IC50 values in the NR cytotoxicity test, the eye irritation classification (weak, moderate and strong) for each chemical used in household products has been established. We evaluated the cytotoxicity of 25 chemicals used for antimicrobial, rubber accelerator, rubber antioxidant, ultraviolet absorber etc. in household products, and estimated the eye irritating potency of these test chemicals according to the criterion.
Application of a wide-field phantom eye for optical coherence tomography and reflectance imaging
NASA Astrophysics Data System (ADS)
Corcoran, Anthony; Muyo, Gonzalo; van Hemert, Jano; Gorman, Alistair; Harvey, Andrew R.
2015-12-01
Optical coherence tomography (OCT) and reflectance imaging are used in clinical practice to measure the thickness and transverse dimensions of retinal features. The recent trend towards increasing the field of view (FOV) of these devices has led to an increasing significance of the optical aberrations of both the human eye and the device. We report the design, manufacture and application of the first phantom eye that reproduces the off-axis optical characteristics of the human eye, and allows the performance assessment of wide-field ophthalmic devices. We base our design and manufacture on the wide-field schematic eye, [Navarro, R. J. Opt. Soc. Am. A, 1985, 2.] as an accurate proxy to the human eye and enable assessment of ophthalmic imaging performance for a ? external FOV. We used multi-material 3D-printed retinal targets to assess imaging performance of the following ophthalmic instruments: the Optos 200Tx, Heidelberg Spectralis, Zeiss FF4 fundus camera and Optos OCT SLO and use the phantom to provide an insight into some of the challenges of wide-field OCT.
NASA Astrophysics Data System (ADS)
Zhang, Mei; Wang, Zhao-Qi; Wang, Yan; Zuo, Tong
2010-10-01
The aim of this research is to study the properties of the transverse chromatic aberration (TCA) after the LASIK refractive surgery based on the individual eye model involving the angle between visual axis and optical axis. According to the measurements of the corneal surfaces, the optical axis lengths and the wavefront aberrations, the individual eye models before and after LASIK refractive surgery are constructed for 15 eyes by using ZEMAX optic design software, while the angle between the visual axis and optical axis is calculated from the data of the anterior corneal surface. The constructed eye models are then used to investigate the variation of the TCA after the surgery. The statistical distributions of the magnitude of the foveal TCA for 15 eyes over the visible spectrum are provided. Finally, we investigate the influence of the TCA on the visual quality and compare the results with previous research. The TCA is an indispensable criterion to evaluate the performance of the refractive surgery. This research is very meaningful for the studies of not only foveal vision but also the peripheral vision.
Modeling the influence of LASIK surgery on optical properties of the human eye
NASA Astrophysics Data System (ADS)
Szul-Pietrzak, Elżbieta; Hachoł, Andrzej; Cieślak, Krzysztof; Drożdż, Ryszard; Podbielska, Halina
2011-11-01
The aim was to model the influence of LASIK surgery on the optical parameters of the human eye and to ascertain which factors besides the central corneal radius of curvature and central thickness play the major role in postsurgical refractive change. Ten patients were included in the study. Pre- and postsurgical measurements included standard refraction, anterior corneal curvature and pachymetry. The optical model used in the analysis was based on the Le Grand and El Hage schematic eye, modified by the measured individual parameters of corneal geometry. A substantial difference between eye refractive error measured after LASIK and estimated from the eye model was observed. In three patients, full correction of the refractive error was achieved. However, analysis of the visual quality in terms of spot diagrams and optical transfer functions of the eye optical system revealed some differences in these measurements. This suggests that other factors besides corneal geometry may play a major role in postsurgical refraction. In this paper we investigated whether the biomechanical properties of the eyeball and changes in intraocular pressure could account for the observed discrepancies.