  1. OPTICAL EYE MODEL: Human eye aberrations: 2. Development of a dynamic model of the human eye based on measurements

    NASA Astrophysics Data System (ADS)

    Galetskii, S. O.; Cherezova, T. Yu; Kudryashov, A. V.

    2008-11-01

    A human eye model based on a flexible semipassive bimorph mirror is proposed and experimentally realised. The model can be used for the real-time reproduction of human eye aberrations and their fluctuations. The accuracy of the reproduction of individual Zernike polynomials and of total eye aberrations of inspected patients is discussed.

  2. Feature-based eye corner detection from static images

    NASA Astrophysics Data System (ADS)

    Xia, Haiying; Yan, Guoping; You, Chao

    2009-10-01

    Eye corner detection is important for eye extraction, face normalization, other facial landmark extraction and so on. We present a feature-based method for eye corner detection from static images in this paper. This method is capable of locating eye corners automatically. The process of eye corner detection is divided into two stages: classifier training and classifier application. For training, two classifiers trained by AdaBoost with Haar-like features, are skillfully designed to detect inner eye corners and outer eye corners. Then, two classifiers are applied to input images to search targets. Eye corners are finally located according to two eye models from targets. Experimental results tested on BioID face database and our own database demonstrate that our method obtains a high accuracy under clutter conditions.

  3. Segmentation method of eye region based on fuzzy logic system for classifying open and closed eyes

    NASA Astrophysics Data System (ADS)

    Kim, Ki Wan; Lee, Won Oh; Kim, Yeong Gon; Hong, Hyung Gil; Lee, Eui Chul; Park, Kang Ryoung

    2015-03-01

    The classification of eye openness and closure has been researched in various fields, e.g., driver drowsiness detection, physiological status analysis, and eye fatigue measurement. For a classification with high accuracy, accurate segmentation of the eye region is required. Most previous research used the segmentation method by image binarization on the basis that the eyeball is darker than skin, but the performance of this approach is frequently affected by thick eyelashes or shadows around the eye. Thus, we propose a fuzzy-based method for classifying eye openness and closure. First, the proposed method uses I and K color information from the HSI and CMYK color spaces, respectively, for eye segmentation. Second, the eye region is binarized using the fuzzy logic system based on I and K inputs, which is less affected by eyelashes and shadows around the eye. The combined image of I and K pixels is obtained through the fuzzy logic system. Third, in order to reflect the effect by all the inference values on calculating the output score of the fuzzy system, we use the revised weighted average method, where all the rectangular regions by all the inference values are considered for calculating the output score. Fourth, the classification of eye openness or closure is successfully made by the proposed fuzzy-based method with eye images of low resolution which are captured in the environment of people watching TV at a distance. By using the fuzzy logic system, our method does not require the additional procedure of training irrespective of the chosen database. Experimental results with two databases of eye images show that our method is superior to previous approaches.

  4. Model-based dose calculations for COMS eye plaque brachytherapy using an anatomically realistic eye phantom

    SciTech Connect

    Lesperance, Marielle; Inglis-Whalen, M.; Thomson, R. M.

    2014-02-15

    Purpose : To investigate the effects of the composition and geometry of ocular media and tissues surrounding the eye on dose distributions for COMS eye plaque brachytherapy with{sup 125}I, {sup 103}Pd, or {sup 131}Cs seeds, and to investigate doses to ocular structures. Methods : An anatomically and compositionally realistic voxelized eye model with a medial tumor is developed based on a literature review. Mass energy absorption and attenuation coefficients for ocular media are calculated. Radiation transport and dose deposition are simulated using the EGSnrc Monte Carlo user-code BrachyDose for a fully loaded COMS eye plaque within a water phantom and our full eye model for the three radionuclides. A TG-43 simulation with the same seed configuration in a water phantom neglecting the plaque and interseed effects is also performed. The impact on dose distributions of varying tumor position, as well as tumor and surrounding tissue media is investigated. Each simulation and radionuclide is compared using isodose contours, dose volume histograms for the lens and tumor, maximum, minimum, and average doses to structures of interest, and doses to voxels of interest within the eye. Results : Mass energy absorption and attenuation coefficients of the ocular media differ from those of water by as much as 12% within the 20–30 keV photon energy range. For all radionuclides studied, average doses to the tumor and lens regions in the full eye model differ from those for the plaque in water by 8%–10% and 13%–14%, respectively; the average doses to the tumor and lens regions differ between the full eye model and the TG-43 simulation by 2%–17% and 29%–34%, respectively. Replacing the surrounding tissues in the eye model with water increases the maximum and average doses to the lens by 2% and 3%, respectively. Substituting the tumor medium in the eye model for water, soft tissue, or an alternate melanoma composition affects tumor dose compared to the default eye model

  5. Human eye haptics-based multimedia.

    PubMed

    Velandia, David; Uribe-Quevedo, Alvaro; Perez-Gutierrez, Byron

    2014-01-01

    Immersive and interactive multimedia applications offer complementary study tools in anatomy as users can explore 3D models while obtaining information about the organ, tissue or part being explored. Haptics increases the sense of interaction with virtual objects improving user experience in a more realistic manner. Common eye studying tools are books, illustrations, assembly models, and more recently these are being complemented with mobile apps whose 3D capabilities, computing power and customers are increasing. The goal of this project is to develop a complementary eye anatomy and pathology study tool using deformable models within a multimedia application, offering the students the opportunity for exploring the eye from up close and within with relevant information. Validation of the tool provided feedback on the potential of the development, along with suggestions on improving haptic feedback and navigation.

  6. A wide angle low coherence interferometry based eye length optometer

    NASA Astrophysics Data System (ADS)

    Meadway, Alexander; Siegwart, John; Wildsoet, Christine; Norton, Thomas; Zhang, Yuhua

    2015-03-01

    Interest in eye growth regulation has burgeoned with the rise in myopia prevalence world-wide. Eye length and eye shape are fundamental metrics for related research, but current in vivo measurement techniques are generally limited to the optical axis of the eye. We describe a high resolution, time domain low coherence interferometry based optometer for measuring the eye length of small animals over a wide field of view. The system is based upon a Michelson interferometer using a superluminescent diode as a source, including a sample arm and a reference arm. The sample arm is split into two paths by a polarisation beam splitter; one focuses the light on the cornea and the other focuses the light on the retina. This method has a high efficiency of detection for reflections from both surfaces. The reference arm contains a custom high speed linear motor with 25 mm stroke and equipped with a precision displacement encoder. Light reflected from the cornea and the retina is combined with the reference beam to generate low coherence interferograms. Two galvo scanners are employed to steer the light to different angles so that the eye length over a field of view of 20° × 20° can be measured. The system has an axial resolution of 6.8 μm (in air) and the motor provides accurate movement, allowing for precise and repeatable measurement of coherence peak positions. Example scans from a tree shrew are presented.

  7. simEye: Computer-based simulation of visual perception under various eye defects using Zernike polynomials.

    PubMed

    Fink, Wolfgang; Micol, Daniel

    2006-01-01

    We describe a computer eye model that allows for aspheric surfaces and a three-dimensional computer-based ray-tracing technique to simulate optical properties of the human eye and visual perception under various eye defects. Eye surfaces, such as the cornea, eye lens, and retina, are modeled or approximated by a set of Zernike polynomials that are fitted to input data for the respective surfaces. A ray-tracing procedure propagates light rays using Snell's law of refraction from an input object (e.g., digital image) through the eye under investigation (i.e., eye with defects to be modeled) to form a retinal image that is upside down and left-right inverted. To obtain a first-order realistic visual perception without having to model or simulate the retina and the visual cortex, this retinal image is then back-propagated through an emmetropic eye (e.g., Gullstrand exact schematic eye model with no additional eye defects) to an output screen of the same dimensions and at the same distance from the eye as the input object. Visual perception under instances of emmetropia, regular astigmatism, irregular astigmatism, and (central symmetric) keratoconus is simulated and depicted. In addition to still images, the computer ray-tracing tool presented here (simEye) permits the production of animated movies. These developments may have scientific and educational value. This tool may facilitate the education and training of both the public, for example, patients before undergoing eye surgery, and those in the medical field, such as students and professionals. Moreover, simEye may be used as a scientific research tool to investigate optical lens systems in general and the visual perception under a variety of eye conditions and surgical procedures such as cataract surgery and laser assisted in situ keratomileusis (LASIK) in particular. PMID:17092160

  8. RapidEye satellite based geo-information system

    NASA Astrophysics Data System (ADS)

    Krischke, M.; Niemeyer, W.; Scherer, S.

    2000-03-01

    It has been found that the ability to offer a guaranteed delivery of information products is the key for any successful commercial Earth observation service. This understanding led to the definition of the RapidEye system and the foundation of the RapidEye AG. RapidEye is a satellite based remote sensing system which permits to have from any point on Earth, at least daily a multispectral (and optionally stereo) imaging capability with a resolution of 5-7 m. It is aimed at establishing an efficient operation for the rapid and accurate reception and processing of thematic information of the Earth's surface and to establish a reliable and sustained service for customers. RapidEye is set up in several steps. The individual steps can be realised according to the system's acceptance on the market. Four satellites are planned already for the first step which permits a revisiting rate of 1/day. In its final configuration, RapidEye consists of a chain of Earth observation satellites which optionally communicate with one another via communication links.

  9. Feature quality-based multimodal unconstrained eye recognition

    NASA Astrophysics Data System (ADS)

    Zhou, Zhi; Du, Eliza Y.; Lin, Yong; Thomas, N. Luke; Belcher, Craig; Delp, Edward J.

    2013-05-01

    Iris recognition has been tested to the most accurate biometrics using high resolution near infrared images. However, it does not work well under visible wavelength illumination. Sclera recognition, however, has been shown to achieve reasonable recognition accuracy under visible wavelengths. Combining iris and sclera recognition together can achieve better recognition accuracy. However, image quality can significantly affect the recognition accuracy. Moreover, in unconstrained situations, the acquired eye images may not be frontally facing. In this research, we proposed a feature quality-based multimodal unconstrained eye recognition method that combine the respective strengths of iris recognition and sclera recognition for human identification and can work with frontal and off-angle eye images. The research results show that the proposed method is very promising.

  10. Height estimations based on eye measurements throughout a gait cycle.

    PubMed

    Yang, Sylvia X M; Larsen, Peter K; Alkjær, Tine; Juul-Kristensen, Birgit; Simonsen, Erik B; Lynnerup, Niels

    2014-03-01

    Anthropometric measurements (e.g. the height to the head, nose tip, eyes or shoulders) of a perpetrator based on video material may be used in criminal cases. However, several height measurements may be difficult to assess as the perpetrators may be disguised by clothes or headwear. The eye height (EH) measurement, on the other hand, is less prone to concealment. The purpose of the present study was to investigate: (1) how the eye height varies during the gait cycle, and (2) how the eye height changes with head position. The eyes were plotted manually in APAS for 16 test subjects during a complete gait cycle. The influence of head tilt on the EH was investigated in 20 healthy men. Markers were attached to the face and the subjects were instructed to stand relaxed, tilt their head to the right, to the left, forward and backward. The marker data for the right eye were used to calculate the EH. The respective deviation and SD from the relaxed standing EH and the EH in the Frankfurt plane, left tilted, right tilted, forward tilted and backward tilted, in addition to the corresponding head tilt angles were calculated. There was no correlation between the height of the subject and the maximum vertical displacement of the EH throughout the gait cycle nor between height of the subjects and the variation of the EH throughout the gait cycle. The average maximum vertical displacement for the test subject group was 4.76 cm (± 1.56 cm). The average EH was lower when the subjects were standing in the relaxed position than in the Frankfurt plane. The average EH was higher in the relaxed position than when the subjects tilted their heads, except when they tilted their heads backwards. The subjects had a slightly larger range of motion to the right than to the left, which was not significant. The results of this study provide a range for eye height estimates and may be readily implemented in forensic case work. It can be used as a reference in height estimates in cases with height

  11. Model of the Human Eye Based on ABCD Matrix

    NASA Astrophysics Data System (ADS)

    González, G. Díaz; Castillo, M. David Iturbe

    2008-04-01

    At the moment several models of the human eye exist, nevertheless the gradient index models of the human lens (crystalline) have received little attention in optometry and vision sciences, although they consider how the refractive index and the refracting power can change with the accommodation. On the other hand, in study fields like ophthalmology and optometry, exist cases where there is a lack of information about the factors that influence the change of refractive power and therefore the focal length of the eye. By such reason, in this paper we present a model of the human eye based on the ABCD matrix in order to describe the propagation of light rays, that can be understood by professional people in optics, ophthalmology and optometry, and the dispersions of the different ocular mediums are taken into account,. The aim of the model is to obtain data about the refractive power of the eye under different considerations, such as: changes in wavelength, radius of curvature and thicknesses of the ocular mediums. We present results of simulations in Matlab of our model, assuming that the object is punctual and is placed to a certain distance of the eye, and considering at the beginning to the crystalline like a medium with fixed refractive index, and after like a gradient lens. By means of graphs, we show the total refractive power of the eye and its form and type of dependence with respect to variations in radius of curvature and thicknesses of the cornea and crystalline, as well as variations in the thickness of the previous and later cameras.

  12. Image-based modeling of the human eye.

    PubMed

    François, Guillaume; Gautron, Pascal; Breton, Gaspard; Bouatouch, Kadi

    2009-01-01

    Rendering realistic organic materials is a challenging issue. The human eye is an important part of nonverbal communication which, consequently, requires specific modeling and rendering techniques to enhance the realism of virtual characters. We propose an image-based method for estimating both iris morphology and scattering features in order to generate convincing images of virtual eyes. In this regard, we develop a technique to unrefract iris photographs. We model the morphology of the human iris as an irregular multilayered tissue. We then approximate the scattering features of the captured iris. Finally, we propose a real-time rendering technique based on the subsurface texture mapping representation and introduce a precomputed refraction function as well as a caustic function, which accounts for the light interactions at the corneal interface. PMID:19590107

  13. Comparison of novel lipid-based eye drops with aqueous eye drops for dry eye: a multicenter, randomized controlled trial

    PubMed Central

    Simmons, Peter A; Carlisle-Wilcox, Cindy; Vehige, Joseph G

    2015-01-01

    Background Dry eye may be caused or exacerbated by deficient lipid secretion. Recently, lipid-containing artificial tears have been developed to alleviate this deficiency. Our study compared the efficacy, safety, and acceptability of lipid-containing eye drops with that of aqueous eye drops. Methods A non-inferiority, randomized, parallel-group, investigator-masked multicenter trial was conducted. Subjects with signs and symptoms of dry eye were randomized to use one of two lipid-containing artificial tears, or one of two aqueous artificial tears. Subjects instilled assigned drops in each eye at least twice daily for 30 days. The primary efficacy analysis tested non-inferiority of a preservative-free lipid tear formulation (LT UD) to a preservative-free aqueous tear formulation (AqT UD) for change in Ocular Surface Disease Index (OSDI) score from baseline at day 30. Secondary measures included OSDI at day 7, tear break-up time (TBUT), corneal and conjunctival staining, Schirmer’s test, acceptability and usage questionnaires, and safety assessments. Results A total of 315 subjects were randomized and included in the analyses. Subjects reported instilling a median of three doses of study eye drops per day in all groups. At days 7 and 30, all groups showed statistically significant improvements from baseline in OSDI (P<0.001) and TBUT (P≤0.005). LT UD was non-inferior to AqT UD for mean change from baseline in OSDI score at day 30. No consistent or clinically relevant differences for the other efficacy variables were observed. Acceptability was generally similar across the groups and there was a low incidence of adverse events. Conclusion In this heterogeneous population of dry eye subjects, there were no clinically significant differences in safety, effectiveness, and acceptability between lipid-containing artificial tears and aqueous eye drops. The results suggest that lipid-containing artificial tears can be used to counteract lipid deficiency that is common in

  14. Driver fatigue alarm based on eye detection and gaze estimation

    NASA Astrophysics Data System (ADS)

    Sun, Xinghua; Xu, Lu; Yang, Jingyu

    2007-11-01

    The driver assistant system has attracted much attention as an essential component of intelligent transportation systems. One task of driver assistant system is to prevent the drivers from fatigue. For the fatigue detection it is natural that the information about eyes should be utilized. The driver fatigue can be divided into two types, one is the sleep with eyes close and another is the sleep with eyes open. Considering that the fatigue detection is related with the prior knowledge and probabilistic statistics, the dynamic Bayesian network is used as the analysis tool to perform the reasoning of fatigue. Two kinds of experiments are performed to verify the system effectiveness, one is based on the video got from the laboratory and another is based on the video got from the real driving situation. Ten persons participate in the test and the experimental result is that, in the laboratory all the fatigue events can be detected, and in the practical vehicle the detection ratio is about 85%. Experiments show that in most of situations the proposed system works and the corresponding performance is satisfying.

  15. Optic nerve head perfusion in normal eyes and eyes with glaucoma using optical coherence tomography-based microangiography

    PubMed Central

    Chen, Chieh-Li; Bojikian, Karine D.; Gupta, Divakar; Wen, Joanne C.; Zhang, Qinqin; Xin, Chen; Kono, Rei; Mudumbai, Raghu C.; Johnstone, Murray A.; Chen, Philip P.

    2016-01-01

    Background To investigate the differences of perfusion in the optic nerve head (ONH) between normal and glaucomatous eyes using optical microangiography (OMAG) based optical coherence tomography (OCT) angiography technique. Methods One eye from each subject was scanned with a 68 kHz Cirrus 5000 HD-OCT-based OMAG prototype system centered at the ONH (Carl Zeiss Meditec Inc, Dublin, CA, USA). Microvascular images were generated from the OMAG dataset by detecting the differences in OCT signal between consecutive B-scans. The pre-laminar layer (preLC) was isolated by a semi-automatic segmentation program. En face OMAG images for preLC were generated using signals with highest blood flow signal intensity. ONH perfusion was quantified as flux, vessel area density, and normalized flux within the ONH. Standard t-tests were performed to analyze the ONH perfusion differences between normal and glaucomatous eyes. Linear regression models were constructed to analyze the correlation between ONH perfusion and other clinical measurements. Results Twenty normal and 21 glaucoma subjects were enrolled. Glaucomatous eyes had significantly lower ONH perfusion in preLC in all three perfusion metrics compared to normal eyes (P≤0.0003). Significant correlations between ONH perfusion and disease severity as well as structural changes were detected in glaucomatous eyes (P≤0.012). Conclusions ONH perfusion detected by OMAG showed significant differences between glaucoma and normal controls and was significantly correlated with disease severity and structural defects in glaucomatous eyes. ONH perfusion measurement using OMAG may provide useful information for detection and monitoring of glaucoma. PMID:27190764

  16. CUE: counterfeit-resistant usable eye movement-based authentication via oculomotor plant characteristics and complex eye movement patterns

    NASA Astrophysics Data System (ADS)

    Komogortsev, Oleg V.; Karpov, Alexey; Holland, Corey D.

    2012-06-01

    The widespread use of computers throughout modern society introduces the necessity for usable and counterfeit-resistant authentication methods to ensure secure access to personal resources such as bank accounts, e-mail, and social media. Current authentication methods require tedious memorization of lengthy pass phrases, are often prone to shouldersurfing, and may be easily replicated (either by counterfeiting parts of the human body or by guessing an authentication token based on readily available information). This paper describes preliminary work toward a counterfeit-resistant usable eye movement-based (CUE) authentication method. CUE does not require any passwords (improving the memorability aspect of the authentication system), and aims to provide high resistance to spoofing and shoulder-surfing by employing the combined biometric capabilities of two behavioral biometric traits: 1) oculomotor plant characteristics (OPC) which represent the internal, non-visible, anatomical structure of the eye; 2) complex eye movement patterns (CEM) which represent the strategies employed by the brain to guide visual attention. Both OPC and CEM are extracted from the eye movement signal provided by an eye tracking system. Preliminary results indicate that the fusion of OPC and CEM traits is capable of providing a 30% reduction in authentication error when compared to the authentication accuracy of individual traits.

  17. Comparison of in vitro eye irritation potential by bovine corneal opacity and permeability (BCOP) assay to erythema scores in human eye sting test of surfactant-based formulations.

    PubMed

    Cater, Kathleen C; Harbell, John W

    2008-01-01

    The bovine corneal opacity and permeability (BCOP) assay can be used to predict relative eye irritation potential of surfactant-based personal care formulations relative to a corporate benchmark. The human eye sting test is typically used to evaluate product claims of no tears/no stinging for children's bath products. A preliminary investigation was conducted to test a hypothesis that the BCOP assay could be used as a prediction model for relative ranking of human eye irritation responses under conditions of a standard human eye sting test to surfactant-based formulations. BCOP assays and human eye sting tests were conducted on 4 commercial and 1 prototype body wash (BW) developed specifically for children or as mild bath products. In the human eye sting test, 10 mul of a 10% dosing solution is instilled into one eye of each panelist (n = 20), and the contralateral eye is dosed with sterile water as a control. Bulbar conjunctival erythema responses of each eye are graded at 30 seconds by an ophthalmologist. The BCOP assay permeability values (optical density at 490 nm [OD(490)]) for the 5 BWs ranged from 0.438 to 1.252 (i.e., least to most irritating). By comparison, the number of panelists exhibiting erythema responses (mild to moderately pink) ranged from 3 of 20 panelists for the least irritating BW to 10 of 20 panelists for the most irritating BW tested. The relative ranking of eye irritation potential of the 5 BWs in the BCOP assay compares favorably with the relative ranking of the BWs in the human eye sting test. Based on these findings, the permeability endpoint of the BCOP assay, as described for surfactant-based formulations, showed promise as a prediction model for relative ranking of conjunctival erythema responses in the human eye. Consequently, screening of prototype formulations in the BCOP assay would allow for formula optimization of mild bath products prior to investment in a human eye sting test.

  18. Optimization of hyaluronan-based eye drop formulations.

    PubMed

    Salzillo, Rosanna; Schiraldi, Chiara; Corsuto, Luisana; D'Agostino, Antonella; Filosa, Rosanna; De Rosa, Mario; La Gatta, Annalisa

    2016-11-20

    Hyaluronan (HA) is frequently incorporated in eye drops to extend the pre-corneal residence time, due to its viscosifying and mucoadhesive properties. Hydrodynamic and rheological evaluations of commercial products are first accomplished revealing molecular weights varying from about 360 to about 1200kDa and viscosity values in the range 3.7-24.2mPa s. The latter suggest that most products could be optimized towards resistance to drainage from the ocular surface. Then, a study aiming to maximize the viscosity and mucoadhesiveness of HA-based preparations is performed. The effect of polymer chain length and concentration is investigated. For the whole range of molecular weights encountered in commercial products, the concentration maximizing performance is identified. Such concentration varies from 0.3 (wt%) for a 1100kDa HA up to 1.0 (wt%) for a 250kDa HA, which is 3-fold higher than the highest concentration on the market. The viscosity and mucoadhesion profiles of optimized formulations are superior than commercial products, especially under conditions simulating in vivo blinking. Thus longer retention on the corneal epithelium can be predicted. An enhanced capacity to protect corneal porcine epithelial cells from dehydration is also demonstrated in vitro. Overall, the results predict formulations with improved efficacy.

  19. Optimization of hyaluronan-based eye drop formulations.

    PubMed

    Salzillo, Rosanna; Schiraldi, Chiara; Corsuto, Luisana; D'Agostino, Antonella; Filosa, Rosanna; De Rosa, Mario; La Gatta, Annalisa

    2016-11-20

    Hyaluronan (HA) is frequently incorporated in eye drops to extend the pre-corneal residence time, due to its viscosifying and mucoadhesive properties. Hydrodynamic and rheological evaluations of commercial products are first accomplished revealing molecular weights varying from about 360 to about 1200kDa and viscosity values in the range 3.7-24.2mPa s. The latter suggest that most products could be optimized towards resistance to drainage from the ocular surface. Then, a study aiming to maximize the viscosity and mucoadhesiveness of HA-based preparations is performed. The effect of polymer chain length and concentration is investigated. For the whole range of molecular weights encountered in commercial products, the concentration maximizing performance is identified. Such concentration varies from 0.3 (wt%) for a 1100kDa HA up to 1.0 (wt%) for a 250kDa HA, which is 3-fold higher than the highest concentration on the market. The viscosity and mucoadhesion profiles of optimized formulations are superior than commercial products, especially under conditions simulating in vivo blinking. Thus longer retention on the corneal epithelium can be predicted. An enhanced capacity to protect corneal porcine epithelial cells from dehydration is also demonstrated in vitro. Overall, the results predict formulations with improved efficacy. PMID:27561497

  20. Implicit prosody mining based on the human eye image capture technology

    NASA Astrophysics Data System (ADS)

    Gao, Pei-pei; Liu, Feng

    2013-08-01

    The technology of eye tracker has become the main methods of analyzing the recognition issues in human-computer interaction. Human eye image capture is the key problem of the eye tracking. Based on further research, a new human-computer interaction method introduced to enrich the form of speech synthetic. We propose a method of Implicit Prosody mining based on the human eye image capture technology to extract the parameters from the image of human eyes when reading, control and drive prosody generation in speech synthesis, and establish prosodic model with high simulation accuracy. Duration model is key issues for prosody generation. For the duration model, this paper put forward a new idea for obtaining gaze duration of eyes when reading based on the eye image capture technology, and synchronous controlling this duration and pronunciation duration in speech synthesis. The movement of human eyes during reading is a comprehensive multi-factor interactive process, such as gaze, twitching and backsight. Therefore, how to extract the appropriate information from the image of human eyes need to be considered and the gaze regularity of eyes need to be obtained as references of modeling. Based on the analysis of current three kinds of eye movement control model and the characteristics of the Implicit Prosody reading, relative independence between speech processing system of text and eye movement control system was discussed. It was proved that under the same text familiarity condition, gaze duration of eyes when reading and internal voice pronunciation duration are synchronous. The eye gaze duration model based on the Chinese language level prosodic structure was presented to change previous methods of machine learning and probability forecasting, obtain readers' real internal reading rhythm and to synthesize voice with personalized rhythm. This research will enrich human-computer interactive form, and will be practical significance and application prospect in terms of

  1. Effects of Bilateral Eye Movements on Gist Based False Recognition in the DRM Paradigm

    ERIC Educational Resources Information Center

    Parker, Andrew; Dagnall, Neil

    2007-01-01

    The effects of saccadic bilateral (horizontal) eye movements on gist based false recognition was investigated. Following exposure to lists of words related to a critical but non-studied word participants were asked to engage in 30s of bilateral vs. vertical vs. no eye movements. Subsequent testing of recognition memory revealed that those who…

  2. Optimizations and Applications in Head-Mounted Video-Based Eye Tracking

    ERIC Educational Resources Information Center

    Li, Feng

    2011-01-01

    Video-based eye tracking techniques have become increasingly attractive in many research fields, such as visual perception and human-computer interface design. The technique primarily relies on the positional difference between the center of the eye's pupil and the first-surface reflection at the cornea, the corneal reflection (CR). This…

  3. Context-Based Questions: Optics in Animal Eyes

    ERIC Educational Resources Information Center

    Kaltakci, Derya; Eryilmaz, Ali

    2011-01-01

    Context is important as a motivational factor for student involvement with physics. The diversity in the types and the functions of animal eyes is an excellent context in which to achieve this goal. There exists a range of subtopics in optics including pinhole, reflection, refraction, and superposition that can be discussed in the context of the…

  4. Intraocular lens design for treating high myopia based on individual eye model

    NASA Astrophysics Data System (ADS)

    Wang, Yang; Wang, Zhaoqi; Wang, Yan; Zuo, Tong

    2007-02-01

    In this research, we firstly design the phakic intraocular lens (PIOL) based on individual eye model with optical design software ZEMAX. The individual PIOL is designed to correct the defocus and astigmatism, and then we compare the PIOL power calculated from the individual eye model with that from the experiential formula. Close values of PIOL power are obtained between the individual eye model and the formula, but the suggested method has more accuracy with more functions. The impact of PIOL decentration on human eye is evaluated, including rotation decentration, flat axis decentration, steep axis decentration and axial movement of PIOL, which is impossible with traditional method. To control the PIOL decentration errors, we give the limit values of PIOL decentration for the specific eye in this study.

  5. Full 3-D OCT-based pseudophakic custom computer eye model.

    PubMed

    Sun, M; Pérez-Merino, P; Martinez-Enriquez, E; Velasco-Ocana, M; Marcos, S

    2016-03-01

    We compared measured wave aberrations in pseudophakic eyes implanted with aspheric intraocular lenses (IOLs) with simulated aberrations from numerical ray tracing on customized computer eye models, built using quantitative 3-D OCT-based patient-specific ocular geometry. Experimental and simulated aberrations show high correlation (R = 0.93; p<0.0001) and similarity (RMS for high order aberrations discrepancies within 23.58%). This study shows that full OCT-based pseudophakic custom computer eye models allow understanding the relative contribution of optical geometrical and surgically-related factors to image quality, and are an excellent tool for characterizing and improving cataract surgery. PMID:27231608

  6. Full 3-D OCT-based pseudophakic custom computer eye model

    PubMed Central

    Sun, M.; Pérez-Merino, P.; Martinez-Enriquez, E.; Velasco-Ocana, M.; Marcos, S.

    2016-01-01

    We compared measured wave aberrations in pseudophakic eyes implanted with aspheric intraocular lenses (IOLs) with simulated aberrations from numerical ray tracing on customized computer eye models, built using quantitative 3-D OCT-based patient-specific ocular geometry. Experimental and simulated aberrations show high correlation (R = 0.93; p<0.0001) and similarity (RMS for high order aberrations discrepancies within 23.58%). This study shows that full OCT-based pseudophakic custom computer eye models allow understanding the relative contribution of optical geometrical and surgically-related factors to image quality, and are an excellent tool for characterizing and improving cataract surgery. PMID:27231608

  7. Improving Eye Motion Sequence Recognition Using Electrooculography Based on Context-Dependent HMM

    PubMed Central

    Shinozaki, Takahiro; Horiuchi, Yasuo; Kuroiwa, Shingo; Furui, Sadaoki; Musha, Toshimitsu

    2016-01-01

    Eye motion-based human-machine interfaces are used to provide a means of communication for those who can move nothing but their eyes because of injury or disease. To detect eye motions, electrooculography (EOG) is used. For efficient communication, the input speed is critical. However, it is difficult for conventional EOG recognition methods to accurately recognize fast, sequentially input eye motions because adjacent eye motions influence each other. In this paper, we propose a context-dependent hidden Markov model- (HMM-) based EOG modeling approach that uses separate models for identical eye motions with different contexts. Because the influence of adjacent eye motions is explicitly modeled, higher recognition accuracy is achieved. Additionally, we propose a method of user adaptation based on a user-independent EOG model to investigate the trade-off between recognition accuracy and the amount of user-dependent data required for HMM training. Experimental results show that when the proposed context-dependent HMMs are used, the character error rate (CER) is significantly reduced compared with the conventional baseline under user-dependent conditions, from 36.0 to 1.3%. Although the CER increases again to 17.3% when the context-dependent but user-independent HMMs are used, it can be reduced to 7.3% by applying the proposed user adaptation method. PMID:27774099

  8. Prevalence of dry eye diseases in hospital-based population in West Bengal, Eastern India.

    PubMed

    Basak, Samar K; Pal, Partha Pratim; Basak, Soham; Bandyopadhyay, Abhijit; Choudhury, Sumit; Sar, Suchanda

    2012-11-01

    To determine the prevalence of dry eye diseases in general clinical ophthalmic practice in a hospital-based population in West Bengal, Eastern India, a cross-sectional study was undertaken among 3023 subjects with the age of > or = 30 years, attending general ophthalmic clinic in a tertiary eye hospital. Demographics, detailed history and 6-items McMonnies' dry eye questionnaire were asked. Tear film break-up time (TBUT), Schirmer-I test, Rose Bengal (RB) staining, slit lamp examination and Meibomian gland dysfunction (MGD) were studied. Dry eye diseases were significantly higher in women than in men ie, 51.9% versus 48.1% (p < 0.01). Symptom-based dry eye (one or more symptoms present often or most of the time) was diagnosed in 1234 subjects (40.8%). With symptoms and at least one sign [TBUT < 10 seconds, RB staining (van Bjisterveld score: 4 or more) and Schirmer-I test = 5 mm in 5 minutes], the prevalence of dry eye was 786 (26%). Different grades of MeibOmian gland dysfunction (MGD) were detected in 957 cases (31.7%). Primary Sjogren syndrome was found in 21.5%; and 10.9% patients of dry eye had some form of systemic collagen vascular disorders. Using computers was not a risk factor in this geographical area. No significant correlation was seen between significant symptoms and positive signs in the study population. The prevalence of dry eye disease is high in West Bengal, Eastern India in hospital-based population. The risk is higher with age, female gender, systemic collagen diseases and with oral antidepressant/anxiolytic medication. Meibomian gland dysfunction is found to be common among dry eye subjects.

  9. Robot Arm Control and Having Meal Aid System with Eye Based Human-Computer Interaction (HCI)

    NASA Astrophysics Data System (ADS)

    Arai, Kohei; Mardiyanto, Ronny

    Robot arm control and having meal aid system with eye based HCI is proposed. The proposed system allows disabled person to select desirable food from the meal tray by their eyes only. Robot arm which is used for retrieving the desirable food is controlled by human eye. At the tip of the robot arm, tiny camera is equipped. Disabled person wear a glass of which a single Head Mount Display: HMD and tiny camera is mounted so that disabled person can take a look at the desired food and retrieve it by looking at the food displayed onto HMD. Experimental results show that disabled person can retrieve the desired food successfully. It also is confirmed that robot arm control by eye based HCI is much faster than that by hands.

  10. Prevalence and risk factors associated with dry eye symptoms: a population based study in Indonesia

    PubMed Central

    Lee, A J; Lee, J; Saw, S-M; Gazzard, G; Koh, D; Widjaja, D; Tan, D T H

    2002-01-01

    Aim: To determine the prevalence and identify associated risk factors for dry eye syndrome in a population in Sumatra, Indonesia. Methods: A one stage cluster sampling procedure was conducted to randomly select 100 households in each of the five rural villages and one provincial town of the Riau province, Indonesia, from April to June 2001. Interviewers collected demographic, lifestyle, and medical data from 1058 participants aged 21 years or over. Symptoms of dry eye were assessed using a six item validated questionnaire. Presence of one or more of the six dry eye symptoms often or all the time was analysed. Presence of pterygium was documented. Results: Prevalence of one or more of the six dry eye symptoms often or all the time adjusted for age was 27.5% (95% confidence interval (CI) 24.8 to 30.2). After adjusting for all significant variables, independent risk factors for dry eye were pterygium (p<0.001, multivariate odds ratio (OR) 1.8; 95% CI 1.4 to 2.5) and a history of current cigarette smoking (p=0.05, multivariate OR 1.5; 95% CI 1.0 to 2.2). Conclusions: This population based study provides prevalence rates of dry eye symptoms in a tropical developing nation. From our findings, pterygium is a possible independent risk factor for dry eye symptoms. PMID:12446361

  11. Glucose sensing using the Brewster reflection: polarimetric ray-tracing based upon an anatomical eye model

    NASA Astrophysics Data System (ADS)

    Bockle, Stefan; Rovati, Luigi; Ansari, Rafat R.

    2003-07-01

    In this paper we present theoretical analysis to support the polarimetric approach for glucose detection in the human eye applying Brewster reflection off the ocular lens. The theoretical eye model of Navarro, which is based upon anatomical data, was used to perform ray-tracing, whereas the electromagnetic and polarization parameters of light propagation through the eye-media were calculated. The errors in glucose concentration determination due to refraction and deviation from the ideal optical path were calculated under different conditions. Effects of using incident linearly and circularly polarized light and variation of intersection condition of the incoming light beam with the anterior corneal surface were taken into consideration. Calculations were performed for a wide spectral range by applying dispersion curves for the eye-media. These simulations show the potential and the limits of the proposed optical approach.

  12. OCT-based crystalline lens topography in accommodating eyes.

    PubMed

    Pérez-Merino, Pablo; Velasco-Ocana, Miriam; Martinez-Enriquez, Eduardo; Marcos, Susana

    2015-12-01

    Custom Spectral Domain Optical Coherence Tomography (SD-OCT) provided with automatic quantification and distortion correction algorithms was used to measure anterior and posterior crystalline lens surface elevation in accommodating eyes and to evaluate relationships between anterior segment surfaces. Nine young eyes were measured at different accommodative demands. Anterior and posterior lens radii of curvature decreased at a rate of 0.78 ± 0.18 and 0.13 ± 0.07 mm/D, anterior chamber depth decreased at 0.04 ± 0.01 mm/D and lens thickness increased at 0.04 ± 0.01 mm/D with accommodation. Three-dimensional surface elevations were estimated by subtracting best fitting spheres. In the relaxed state, the spherical term accounted for most of the surface irregularity in the anterior lens (47%) and astigmatism (70%) in the posterior lens. However, in accommodated lenses astigmatism was the predominant surface irregularity (90%) in the anterior lens. The RMS of high-order irregularities of the posterior lens surface was statistically significantly higher than that of the anterior lens surface (x2.02, p<0.0001). There was significant negative correlation in vertical coma (Z3 (-1)) and oblique trefoil (Z3 (-3)) between lens surfaces. The astigmatic angle showed high degree of alignment between corneal surfaces, moderate between corneal and anterior lens surface (~27 deg), but differed by ~80 deg between the anterior and posterior lens surfaces (including relative anterior/posterior lens astigmatic angle shifts (10-20 deg). PMID:26713216

  13. Gaze Stripes: Image-Based Visualization of Eye Tracking Data.

    PubMed

    Kurzhals, Kuno; Hlawatsch, Marcel; Heimerl, Florian; Burch, Michael; Ertl, Thomas; Weiskopf, Daniel

    2016-01-01

    We present a new visualization approach for displaying eye tracking data from multiple participants. We aim to show the spatio-temporal data of the gaze points in the context of the underlying image or video stimulus without occlusion. Our technique, denoted as gaze stripes, does not require the explicit definition of areas of interest but directly uses the image data around the gaze points, similar to thumbnails for images. A gaze stripe consists of a sequence of such gaze point images, oriented along a horizontal timeline. By displaying multiple aligned gaze stripes, it is possible to analyze and compare the viewing behavior of the participants over time. Since the analysis is carried out directly on the image data, expensive post-processing or manual annotation are not required. Therefore, not only patterns and outliers in the participants' scanpaths can be detected, but the context of the stimulus is available as well. Furthermore, our approach is especially well suited for dynamic stimuli due to the non-aggregated temporal mapping. Complementary views, i.e., markers, notes, screenshots, histograms, and results from automatic clustering, can be added to the visualization to display analysis results. We illustrate the usefulness of our technique on static and dynamic stimuli. Furthermore, we discuss the limitations and scalability of our approach in comparison to established visualization techniques.

  14. Gaze Stripes: Image-Based Visualization of Eye Tracking Data.

    PubMed

    Kurzhals, Kuno; Hlawatsch, Marcel; Heimerl, Florian; Burch, Michael; Ertl, Thomas; Weiskopf, Daniel

    2016-01-01

    We present a new visualization approach for displaying eye tracking data from multiple participants. We aim to show the spatio-temporal data of the gaze points in the context of the underlying image or video stimulus without occlusion. Our technique, denoted as gaze stripes, does not require the explicit definition of areas of interest but directly uses the image data around the gaze points, similar to thumbnails for images. A gaze stripe consists of a sequence of such gaze point images, oriented along a horizontal timeline. By displaying multiple aligned gaze stripes, it is possible to analyze and compare the viewing behavior of the participants over time. Since the analysis is carried out directly on the image data, expensive post-processing or manual annotation are not required. Therefore, not only patterns and outliers in the participants' scanpaths can be detected, but the context of the stimulus is available as well. Furthermore, our approach is especially well suited for dynamic stimuli due to the non-aggregated temporal mapping. Complementary views, i.e., markers, notes, screenshots, histograms, and results from automatic clustering, can be added to the visualization to display analysis results. We illustrate the usefulness of our technique on static and dynamic stimuli. Furthermore, we discuss the limitations and scalability of our approach in comparison to established visualization techniques. PMID:26529744

  15. Feature-based attention and spatial selection in frontal eye fields during natural scene search.

    PubMed

    Ramkumar, Pavan; Lawlor, Patrick N; Glaser, Joshua I; Wood, Daniel K; Phillips, Adam N; Segraves, Mark A; Kording, Konrad P

    2016-09-01

    When we search for visual objects, the features of those objects bias our attention across the visual landscape (feature-based attention). The brain uses these top-down cues to select eye movement targets (spatial selection). The frontal eye field (FEF) is a prefrontal brain region implicated in selecting eye movements and is thought to reflect feature-based attention and spatial selection. Here, we study how FEF facilitates attention and selection in complex natural scenes. We ask whether FEF neurons facilitate feature-based attention by representing search-relevant visual features or whether they are primarily involved in selecting eye movement targets in space. We show that search-relevant visual features are weakly predictive of gaze in natural scenes and additionally have no significant influence on FEF activity. Instead, FEF activity appears to primarily correlate with the direction of the upcoming eye movement. Our result demonstrates a concrete need for better models of natural scene search and suggests that FEF activity during natural scene search is explained primarily by spatial selection. PMID:27250912

  16. Face and eye tracking for sub-hologram-based digital holographic display system

    NASA Astrophysics Data System (ADS)

    Lee, Heekyung; Park, Min-sik; Cha, Jihun; Kim, Jinwoong

    2012-06-01

    Sub-hologram based holographic display method is one of the most practical approaches for realizing big size holographic display. However, this method needs highly accurate face and eye tracking function in real-time to enable precise steering of backlight and generation of corresponding sub-hologram for each video frame. We theoretically estimated several parameters, such as accuracy, speed and distance from an observer, required for the eye tracking function and developed an eye tracking system whose objective is accurate and fast 3D positioning of left and right pupils of an observer. Experimental results show that the system obtains accurate 3D pupil positions with an error less than 3 mm at 30 frames per second under disturbing conditions such as more than 2m distance and an observer wearing glasses. Therefore, our implementation could be sufficiently applied to the sub-hologram based display system.

  17. Spatial Resolution Effects of Remote Sensing Informed Soil Nutrient Models Based on Landsat 8, RapidEye, WorldView-2 and GeoEye-1 Images

    NASA Astrophysics Data System (ADS)

    Xu, Y.; Grunwald, S.; Smith, S. E.; Abd-Elrahman, A.; Clingensmith, C. M.; Wani, S.

    2015-12-01

    Soil nutrient storage is essential and important to maintain food security and soil security in smallholder farm settings. The objective of this research was to analyze the spatial resolution effects of different remote sensing images on soil prediction models in Kothapally, India. We utilized Bayesian kriging (BK) to characterize the spatial pattern of total nitrogen (TN) and exchangeable potassium (Kex) in the topsoil (0-15 cm) at different spatial resolutions by incorporating spectral indices from Landsat 8 (30m), RapidEye (5m) and WorldView-2/GeoEye-1 images (2m). The band ratio of red to green, red to blue and green to blue, Crust Index and Atmospherically Resistant Vegetation Index from multiple images generally had high linear correlations with TN and Kex. The BK model of TN based on WorldView-2 and GeoEye-1 attained the highest model fit (R2=0.41) and lowest prediction error (RMSE=171.35 mg kg-1) compared with the BK models of TN based on Landsat 8 (R2=0.30; RMSE=182.26 mg kg-1) and RapidEye (R2=0.28; RMSE=183.52 mg kg-1). The BK model of Kex based on Landsat 8 had the highest model fit (R2=0.55) and the second lowest prediction error (RMSE=79.57 mg kg-1) compared with the BK models of Kex based on WorldView-2 and GeoEye-1 (R2=0.52; RMSE=79.42 mg kg-1) and RapidEye (R2=0.47; RMSE=83.91 mg kg-1). The lowest prediction fit and highest prediction error of soil TN and Kex models based on RapidEye suggest that the effect of fine spatial remote sensing spectral data inputs do not always lead to an increase of model fit. Soil maps based on WorldView-2 and GeoEye-1 have significant advantages in characterizing the variation of soil TN and Kex spatial pattern in smallholder farm settings compared with coarser maps. This research suggests that Digital Soil Mapping utilizing remote sensing spectral data from WorldView-2 and GeoEye-1 has high potential to be widely applied in smallholder farm settings and help smallholder farmers manage their soils and attain soil

  18. Online Learners’ Reading Ability Detection Based on Eye-Tracking Sensors

    PubMed Central

    Zhan, Zehui; Zhang, Lei; Mei, Hu; Fong, Patrick S. W.

    2016-01-01

    The detection of university online learners’ reading ability is generally problematic and time-consuming. Thus the eye-tracking sensors have been employed in this study, to record temporal and spatial human eye movements. Learners’ pupils, blinks, fixation, saccade, and regression are recognized as primary indicators for detecting reading abilities. A computational model is established according to the empirical eye-tracking data, and applying the multi-feature regularization machine learning mechanism based on a Low-rank Constraint. The model presents good generalization ability with an error of only 4.9% when randomly running 100 times. It has obvious advantages in saving time and improving precision, with only 20 min of testing required for prediction of an individual learner’s reading ability. PMID:27626418

  19. Characterization of gamma irradiated petrolatum eye ointment base by headspace-gas chromatography-mass spectrometry.

    PubMed

    Hong, Lan; Altorfer, Hans

    2002-06-20

    The effects of gamma irradiation on petrolatum eye ointment base (EOB) and its ingredients (white petrolatum, liquid paraffin, and wool fat) were studied at different irradiation doses. Forty-one volatile radiolysis products were detected and identified by a combined system of headspace-gas chromatography-mass spectrometry (HS-GC-MS). The characteristics of the radiolysis products and the degradation pathway were discussed in each case, respectively. GC method demonstrates that the component distribution patterns of eye ointment as well as its individual ingredients have no differences before and after gamma irradiation. The influence of gamma treatment on EOB was quantitatively determined at 15, 25 and 50 kGy. The concentrations of the radiolysis products increase linearly with increasing doses. Both qualitative and quantitative data show that irradiated eye ointment is safe for human use.

  20. Online Learners' Reading Ability Detection Based on Eye-Tracking Sensors.

    PubMed

    Zhan, Zehui; Zhang, Lei; Mei, Hu; Fong, Patrick S W

    2016-01-01

    The detection of university online learners' reading ability is generally problematic and time-consuming. Thus the eye-tracking sensors have been employed in this study, to record temporal and spatial human eye movements. Learners' pupils, blinks, fixation, saccade, and regression are recognized as primary indicators for detecting reading abilities. A computational model is established according to the empirical eye-tracking data, and applying the multi-feature regularization machine learning mechanism based on a Low-rank Constraint. The model presents good generalization ability with an error of only 4.9% when randomly running 100 times. It has obvious advantages in saving time and improving precision, with only 20 min of testing required for prediction of an individual learner's reading ability. PMID:27626418

  1. Prior Knowledge and Online Inquiry-Based Science Reading: Evidence from Eye Tracking

    ERIC Educational Resources Information Center

    Ho, Hsin Ning Jessie; Tsai, Meng-Jung; Wang, Ching-Yeh; Tsai, Chin-Chung

    2014-01-01

    This study employed eye-tracking technology to examine how students with different levels of prior knowledge process text and data diagrams when reading a web-based scientific report. Students' visual behaviors were tracked and recorded when they read a report demonstrating the relationship between the greenhouse effect and global climate…

  2. Bird's-eye view on noise-based logic

    NASA Astrophysics Data System (ADS)

    Kish, Laszlo B.; Granqvist, Claes G.; Horvath, Tamas; Klappenecker, Andreas; Wen, He; Bezrukov, Sergey M.

    2014-09-01

    Noise-based logic is a practically deterministic logic scheme inspired by the randomness of neural spikes and uses a system of uncorrelated stochastic processes and their superposition to represent the logic state. We briefly discuss various questions such as (i) What does practical determinism mean? (ii) Is noise-based logic a Turing machine? (iii) Is there hope to beat (the dreams of) quantum computation by a classical physical noise-based processor, and what are the minimum hardware requirements for that? Finally, (iv) we address the problem of random number generators and show that the common belief that quantum number generators are superior to classical (thermal) noise-based generators is nothing but a myth.

  3. An integrated Mach-Zehnder modulator bias controller based on eye-amplitude monitoring

    NASA Astrophysics Data System (ADS)

    Kim, Min-Hyeong; Jung, Hyun-Yong; Zimmermann, Lars; Choi, Woo-Young

    2016-03-01

    A novel integrated Mach-Zehnder modulator (MZM) bias controller based on eye-amplitude monitoring is demonstrated in IHP's 0.25-μm BiCMOS technology. The bias controller monitors the MZM output light, automatically moves the MZM bias voltage to the optimal value that produces the largest eye amplitude, and maintains it there even if the MZM transfer characteristics change due to thermal drift. The controller is based on the feedback loop consisting of Si photodetector, trans-impedance amplifier, rectifier, square amplifier, track-and-hold circuit, comparator, polarity changer, and charge-pump, all of which are monolithically integrated. The area of the controller is 0.083-mm2 and it consumes 92.5-mW. Our bias controller shows successful operation for a commercially-available 850-nm LiNbO3 MZM modulated with 3-Gbps PRBS data by maintaining a very clean eye for at least 30 minutes. Without the controller, the eye for the same MZM modulation becomes completely closed due to thermal drift. The data rate is limited by the Si PD integrated in the controller not by the controller architecture. Since our controller is based on the Si BiCMOS technology which can also provide integrated Si photonics devices on the same Si, it has a great potential for realizing a Si MZM with an integrated bias controller, which should fully demonstrate the advantage of electronic-photonic integrated circuit technology.

  4. Eye Infections

    MedlinePlus

    Your eyes can get infections from bacteria, fungi, or viruses. Eye infections can occur in different parts of the eye and can affect just one eye or both. Two common eye infections are Conjunctivitis - also known as pinkeye. Conjunctivitis is ...

  5. Gaze estimation for off-angle iris recognition based on the biometric eye model

    NASA Astrophysics Data System (ADS)

    Karakaya, Mahmut; Barstow, Del; Santos-Villalobos, Hector; Thompson, Joseph; Bolme, David; Boehnen, Christopher

    2013-05-01

    Iris recognition is among the highest accuracy biometrics. However, its accuracy relies on controlled high quality capture data and is negatively affected by several factors such as angle, occlusion, and dilation. Non-ideal iris recognition is a new research focus in biometrics. In this paper, we present a gaze estimation method designed for use in an off-angle iris recognition framework based on the ORNL biometric eye model. Gaze estimation is an important prerequisite step to correct an off-angle iris images. To achieve the accurate frontal reconstruction of an off-angle iris image, we first need to estimate the eye gaze direction from elliptical features of an iris image. Typically additional information such as well-controlled light sources, head mounted equipment, and multiple cameras are not available. Our approach utilizes only the iris and pupil boundary segmentation allowing it to be applicable to all iris capture hardware. We compare the boundaries with a look-up-table generated by using our biologically inspired biometric eye model and find the closest feature point in the look-up-table to estimate the gaze. Based on the results from real images, the proposed method shows effectiveness in gaze estimation accuracy for our biometric eye model with an average error of approximately 3.5 degrees over a 50 degree range.

  6. Research on the image fusion and target extraction based on bionic compound eye system

    NASA Astrophysics Data System (ADS)

    Zhang, Shaowei; Hao, Qun; Song, Yong; Wang, Zihan; Zhang, Kaiyu; Zhang, Shiyu

    2015-08-01

    People attach more and more importance to bionic compound eye due to its advantages such as small volume, large field of view and sensitivity to high-speed moving objects. Small field of view and large volume are the disadvantages of traditional image sensor and in order to avoid these defects, this paper intends to build a set of compound eye system based on insect compound eye structure and visual processing mechanism. In the center of this system is the primary sensor which has high resolution ratio. The primary sensor is surrounded by the other six sensors which have low resolution ratio. Based on this system, this paper will study the target image fusion and extraction method by using plane compound eye structure. This paper designs a control module which can combine the distinguishing features of high resolution image with local features of low resolution image so as to conduct target detection, recognition and location. Compared with traditional ways, the way of high resolution in the center and low resolution around makes this system own the advantages of high resolution and large field of view and enables the system to detect the object quickly and recognize the object accurately.

  7. Gaze Estimation for Off-Angle Iris Recognition Based on the Biometric Eye Model

    SciTech Connect

    Karakaya, Mahmut; Barstow, Del R; Santos-Villalobos, Hector J; Thompson, Joseph W; Bolme, David S; Boehnen, Chris Bensing

    2013-01-01

    Iris recognition is among the highest accuracy biometrics. However, its accuracy relies on controlled high quality capture data and is negatively affected by several factors such as angle, occlusion, and dilation. Non-ideal iris recognition is a new research focus in biometrics. In this paper, we present a gaze estimation method designed for use in an off-angle iris recognition framework based on the ANONYMIZED biometric eye model. Gaze estimation is an important prerequisite step to correct an off-angle iris images. To achieve the accurate frontal reconstruction of an off-angle iris image, we first need to estimate the eye gaze direction from elliptical features of an iris image. Typically additional information such as well-controlled light sources, head mounted equipment, and multiple cameras are not available. Our approach utilizes only the iris and pupil boundary segmentation allowing it to be applicable to all iris capture hardware. We compare the boundaries with a look-up-table generated by using our biologically inspired biometric eye model and find the closest feature point in the look-up-table to estimate the gaze. Based on the results from real images, the proposed method shows effectiveness in gaze estimation accuracy for our biometric eye model with an average error of approximately 3.5 degrees over a 50 degree range.

  8. From neural-based object recognition toward microelectronic eyes

    NASA Technical Reports Server (NTRS)

    Sheu, Bing J.; Bang, Sa Hyun

    1994-01-01

    Engineering neural network systems are best known for their abilities to adapt to the changing characteristics of the surrounding environment by adjusting system parameter values during the learning process. Rapid advances in analog current-mode design techniques have made possible the implementation of major neural network functions in custom VLSI chips. An electrically programmable analog synapse cell with large dynamic range can be realized in a compact silicon area. New designs of the synapse cells, neurons, and analog processor are presented. A synapse cell based on Gilbert multiplier structure can perform the linear multiplication for back-propagation networks. A double differential-pair synapse cell can perform the Gaussian function for radial-basis network. The synapse cells can be biased in the strong inversion region for high-speed operation or biased in the subthreshold region for low-power operation. The voltage gain of the sigmoid-function neurons is externally adjustable which greatly facilitates the search of optimal solutions in certain networks. Various building blocks can be intelligently connected to form useful industrial applications. Efficient data communication is a key system-level design issue for large-scale networks. We also present analog neural processors based on perceptron architecture and Hopfield network for communication applications. Biologically inspired neural networks have played an important role towards the creation of powerful intelligent machines. Accuracy, limitations, and prospects of analog current-mode design of the biologically inspired vision processing chips and cellular neural network chips are key design issues.

  9. MEMS scanner mirror based system for retina scanning and in eye projection

    NASA Astrophysics Data System (ADS)

    Woittennek, Franziska; Knobbe, Jens; Pügner, Tino; Dallmann, Hans-Georg; Schelinski, Uwe; Grüger, Heinrich

    2015-02-01

    Many applications could benefit from miniaturized systems to scan blood vessels behind the retina in the human eye, so called "retina scanning". This reaches from access control to sophisticated security applications and medical devices. High volume systems for consumer applications require low cost and a user friendly operation. For example this includes no need for removal of glasses and self-adjustment, in turn guidance of focus and point of attraction by simultaneous projection for the user. A new system has been designed based on the well-known resonantly driven 2-d scanner mirror of Fraunhofer IPMS. A combined NIR and VIS laser system illuminates the eye through an eye piece designed for an operating distance allowing the use of glasses and granting sufficient field of view. This usability feature was considered to be more important than highest miniaturization. The modulated VIS laser facilitates the projection of an image directly onto the retina. The backscattered light from the continuous NIR laser contains the information of the blood vessels and is detected by a highly sensitive photo diode. A demonstrational setup has been realized including readout and driving electronics. The laser power was adjusted to an eye-secure level. Additional security features were integrated. Test measurements revealed promising results. In a first demonstration application the detection of biometric pattern of the blood vessels was evaluated for issues authentication in.

  10. NGS-based Molecular diagnosis of 105 eyeGENE(®) probands with Retinitis Pigmentosa.

    PubMed

    Ge, Zhongqi; Bowles, Kristen; Goetz, Kerry; Scholl, Hendrik P N; Wang, Feng; Wang, Xinjing; Xu, Shan; Wang, Keqing; Wang, Hui; Chen, Rui

    2015-12-15

    The National Ophthalmic Disease Genotyping and Phenotyping Network (eyeGENE(®)) was established in an effort to facilitate basic and clinical research of human inherited eye disease. In order to provide high quality genetic testing to eyeGENE(®)'s enrolled patients which potentially aids clinical diagnosis and disease treatment, we carried out a pilot study and performed Next-generation sequencing (NGS) based molecular diagnosis for 105 Retinitis Pigmentosa (RP) patients randomly selected from the network. A custom capture panel was designed, which incorporated 195 known retinal disease genes, including 61 known RP genes. As a result, disease-causing mutations were identified in 52 out of 105 probands (solving rate of 49.5%). A total of 82 mutations were identified, and 48 of them were novel. Interestingly, for three probands the molecular diagnosis was inconsistent with the initial clinical diagnosis, while for five probands the molecular information suggested a different inheritance model other than that assigned by the physician. In conclusion, our study demonstrated that NGS target sequencing is efficient and sufficiently precise for molecular diagnosis of a highly heterogeneous patient cohort from eyeGENE(®).

  11. Eye cosmetics.

    PubMed

    Draelos, Z K

    1991-01-01

    Eye cosmetics are useful to highlight and emphasize the eyes. Currently available eye cosmetics include eye shadows, eye shadow setting creams, under-eye concealers, eye-liners, mascaras, artificial eyelashes, and eyebrow pencils. Special care must be taken when patients with sensitive skin or contact lens wearers select eye cosmetics. Eye cosmetics may also be the cause of either irritant or allergic contact dermatitis, which are two causes of the upper-eyelid dermatitis syndrome.

  12. Multitarget tracking system based on an infrared fish-eye lens.

    PubMed

    Li, Gang; Li, Li; Shen, Hongbin; He, Yongqiang; Huang, Jingxia; Mao, Shaojuan; Wang, Yuanbo

    2013-11-20

    A multitarget tracking system based on an infrared (IR) fish-eye lens is built to satisfy urgent requirements of large-field IR, multitarget, real-time reconnaissance and tracking. Utilizing an IR fish-eye lens and a 512×512 pixel PtSi detector, the system can detect threatening targets at the whole space domain and the whole time domain. The hardware of the system based on a dual-digital signal processor is designed to implement data processing for multitarget tracking algorithms, which include a track initiation algorithm and a modified generalized probability data association algorithm. We also carried out a tracking experiment for two aerial maneuvering targets. Comparing the theoretical and experimental tracks, the availability of the system and the real-time capability of multitarget tracking are validated.

  13. Evaluation of the IrisPlex DNA-based eye color prediction assay in a United States population.

    PubMed

    Dembinski, Gina M; Picard, Christine J

    2014-03-01

    DNA phenotyping is a rapidly developing area of research in forensic biology. Externally visible characteristics (EVCs) can be determined based on genotype data, specifically based on single nucleotide polymorphisms (SNPs). These SNPs are chosen based on their association with genes related to the phenotypic expression of interest, with known examples in eye, hair, and skin color traits. DNA phenotyping has forensic importance when unknown biological samples at a crime scene do not result in a criminal database hit; a phenotypic profile of the sample can therefore be used to develop investigational leads. IrisPlex, an eye color prediction assay, has previously shown high prediction rates for blue and brown eye color in a Dutch European population. The objective of this work was to evaluate its utility in a North American population. We evaluated six SNPs included in the IrisPlex assay in population sample collected from a USA college campus. We used a quantitative method of eye color classification based on (RGB) color components of digital photographs of the eye taken from each study volunteer so that each eye was placed in one of three eye color categories: brown, intermediate, or blue. Objective color classification was shown to correlate with basic human visual determination making it a feasible option for use in future prediction assay development. Using these samples and various models, the maximum prediction accuracies of the IrisPlex system after allele frequency adjustment was 58% and 95% brown and blue eye color predictions, respectively, and 11% for intermediate eye colors. Future developments should include incorporation of additional informative SNPs, specifically related to the intermediate eye color, and we recommend the use of a Bayesian approach as a prediction model as likelihood ratios can be determined for reporting purposes.

  14. Eye pain

    MedlinePlus

    Ophthalmalgia; Pain - eye ... Pain in the eye can be an important symptom of a health problem. Make sure you tell your health care provider if you have eye pain that does not go away. Tired eyes or ...

  15. Eye Cancer

    MedlinePlus

    ... Eye Cancer - Overview Request Permissions Print to PDF Eye Cancer - Overview Approved by the Cancer.Net Editorial Board , ... Cancer Research and Advocacy Survivorship Blog About Us Eye Cancer Guide Cancer.Net Guide Eye Cancer Overview Statistics ...

  16. Spectral optimization simulation of white light based on the photopic eye-sensitivity curve

    NASA Astrophysics Data System (ADS)

    Dai, Qi; Hao, Luoxi; Lin, Yi; Cui, Zhe

    2016-02-01

    Spectral optimization simulation of white light is studied to boost maximum attainable luminous efficacy of radiation at high color-rendering index (CRI) and various color temperatures. The photopic eye-sensitivity curve V(λ) is utilized as the dominant portion of white light spectra. Emission spectra of a blue InGaN light-emitting diode (LED) and a red AlInGaP LED are added to the spectrum of V(λ) to match white color coordinates. It is demonstrated that at the condition of color temperature from 2500 K to 6500 K and CRI above 90, such white sources can achieve spectral efficacy of 330-390 lm/W, which is higher than the previously reported theoretical maximum values. We show that this eye-sensitivity-based approach also has advantages on component energy conversion efficiency compared with previously reported optimization solutions.

  17. A paper-based cantilever array sensor: Monitoring volatile organic compounds with naked eye.

    PubMed

    Fraiwan, Arwa; Lee, Hankeun; Choi, Seokheun

    2016-09-01

    Volatile organic compound (VOC) detection is critical for controlling industrial and commercial emissions, environmental monitoring, and public health. Simple, portable, rapid and low-cost VOC sensing platforms offer the benefits of on-site and real-time monitoring anytime and anywhere. The best and most practically useful approaches to monitoring would include equipment-free and power-free detection by the naked eye. In this work, we created a novel, paper-based cantilever sensor array that allows simple and rapid naked-eye VOC detection without the need for power, electronics or readout interface/equipment. This simple VOC detection method was achieved using (i) low-cost paper materials as a substrate and (ii) swellable thin polymers adhered to the paper. Upon exposure to VOCs, the polymer swelling adhered to the paper-based cantilever, inducing mechanical deflection that generated a distinctive composite pattern of the deflection angles for a specific VOC. The angle is directly measured by the naked eye on a 3-D protractor printed on a paper facing the cantilevers. The generated angle patterns are subjected to statistical algorithms (linear discriminant analysis (LDA)) to classify each VOC sample and selectively detect a VOC. We classified four VOC samples with 100% accuracy using LDA. PMID:27343578

  18. A paper-based cantilever array sensor: Monitoring volatile organic compounds with naked eye.

    PubMed

    Fraiwan, Arwa; Lee, Hankeun; Choi, Seokheun

    2016-09-01

    Volatile organic compound (VOC) detection is critical for controlling industrial and commercial emissions, environmental monitoring, and public health. Simple, portable, rapid and low-cost VOC sensing platforms offer the benefits of on-site and real-time monitoring anytime and anywhere. The best and most practically useful approaches to monitoring would include equipment-free and power-free detection by the naked eye. In this work, we created a novel, paper-based cantilever sensor array that allows simple and rapid naked-eye VOC detection without the need for power, electronics or readout interface/equipment. This simple VOC detection method was achieved using (i) low-cost paper materials as a substrate and (ii) swellable thin polymers adhered to the paper. Upon exposure to VOCs, the polymer swelling adhered to the paper-based cantilever, inducing mechanical deflection that generated a distinctive composite pattern of the deflection angles for a specific VOC. The angle is directly measured by the naked eye on a 3-D protractor printed on a paper facing the cantilevers. The generated angle patterns are subjected to statistical algorithms (linear discriminant analysis (LDA)) to classify each VOC sample and selectively detect a VOC. We classified four VOC samples with 100% accuracy using LDA.

  19. Eye tracker.

    PubMed

    Pruehsner, W; Enderle, J D

    1999-01-01

    A device that records saccadic eye movements, the Eye Tracker, is presented in this paper. The Eye Tracker utilizes infra-red technology mounted on fully adjustable goggles to follow eye movements targeted by either a goggles mounted HUD type display or a wall mounted light bank. Output from the goggles is remotely sent to a PC type computer, which leads to device portability. The goggles can also maintain output data in an internal memory for latter download. The user interface is Windows based with the output from the goggles represented as a trace map or plotted points. This output can also be saved or printed for future reference. The user interface can be used on any PC type computer. The device is designed with reference to standard ISO design methodology. Safety in design and final product usage has also been addressed with reference to standard ISO type procedures. Device accuracy is maintained by precise construction of the IR units in the goggles and tight control of cross talk between each IR device plus filtering of ambient light signals. Also, a reset feature is included to maintain equal baseline control. An automatic switching device is included in the goggles to allow the Eye Tracker to "warm up," assuring that equal IR power is delivered for each subject tested. The IR units in the goggles are also modular in case replacement is required. PMID:11143354

  20. Assessing Visual Attention Using Eye Tracking Sensors in Intelligent Cognitive Therapies Based on Serious Games

    PubMed Central

    Frutos-Pascual, Maite; Garcia-Zapirain, Begonya

    2015-01-01

    This study examines the use of eye tracking sensors as a means to identify children's behavior in attention-enhancement therapies. For this purpose, a set of data collected from 32 children with different attention skills is analyzed during their interaction with a set of puzzle games. The authors of this study hypothesize that participants with better performance may have quantifiably different eye-movement patterns from users with poorer results. The use of eye trackers outside the research community may help to extend their potential with available intelligent therapies, bringing state-of-the-art technologies to users. The use of gaze data constitutes a new information source in intelligent therapies that may help to build new approaches that are fully-customized to final users' needs. This may be achieved by implementing machine learning algorithms for classification. The initial study of the dataset has proven a 0.88 (±0.11) classification accuracy with a random forest classifier, using cross-validation and hierarchical tree-based feature selection. Further approaches need to be examined in order to establish more detailed attention behaviors and patterns among children with and without attention problems. PMID:25985158

  1. An eye movement based reading intervention in lexical and segmental readers with acquired dyslexia.

    PubMed

    Ablinger, Irene; von Heyden, Kerstin; Vorstius, Christian; Halm, Katja; Huber, Walter; Radach, Ralph

    2014-01-01

    Due to their brain damage, aphasic patients with acquired dyslexia often rely to a greater extent on lexical or segmental reading procedures. Thus, therapy intervention is mostly targeted on the more impaired reading strategy. In the present work we introduce a novel therapy approach based on real-time measurement of patients' eye movements as they attempt to read words. More specifically, an eye movement contingent technique of stepwise letter de-masking was used to support sequential reading, whereas fixation-dependent initial masking of non-central letters stimulated a lexical (parallel) reading strategy. Four lexical and four segmental readers with acquired central dyslexia received our intensive reading intervention. All participants showed remarkable improvements as evident in reduced total reading time, a reduced number of fixations per word and improved reading accuracy. Both types of intervention led to item-specific training effects in all subjects. A generalisation to untrained items was only found in segmental readers after the lexical training. Eye movement analyses were also used to compare word processing before and after therapy, indicating that all patients, with one exclusion, maintained their preferred reading strategy. However, in several cases the balance between sequential and lexical processing became less extreme, indicating a more effective individual interplay of both word processing routes.

  2. Assessing visual attention using eye tracking sensors in intelligent cognitive therapies based on serious games.

    PubMed

    Frutos-Pascual, Maite; Garcia-Zapirain, Begonya

    2015-05-12

    This study examines the use of eye tracking sensors as a means to identify children's behavior in attention-enhancement therapies. For this purpose, a set of data collected from 32 children with different attention skills is analyzed during their interaction with a set of puzzle games. The authors of this study hypothesize that participants with better performance may have quantifiably different eye-movement patterns from users with poorer results. The use of eye trackers outside the research community may help to extend their potential with available intelligent therapies, bringing state-of-the-art technologies to users. The use of gaze data constitutes a new information source in intelligent therapies that may help to build new approaches that are fully-customized to final users' needs. This may be achieved by implementing machine learning algorithms for classification. The initial study of the dataset has proven a 0.88 (±0.11) classification accuracy with a random forest classifier, using cross-validation and hierarchical tree-based feature selection. Further approaches need to be examined in order to establish more detailed attention behaviors and patterns among children with and without attention problems.

  3. Collaborative EDNAP exercise on the IrisPlex system for DNA-based prediction of human eye colour.

    PubMed

    Chaitanya, Lakshmi; Walsh, Susan; Andersen, Jeppe Dyrberg; Ansell, Ricky; Ballantyne, Kaye; Ballard, David; Banemann, Regine; Bauer, Christiane Maria; Bento, Ana Margarida; Brisighelli, Francesca; Capal, Tomas; Clarisse, Lindy; Gross, Theresa E; Haas, Cordula; Hoff-Olsen, Per; Hollard, Clémence; Keyser, Christine; Kiesler, Kevin M; Kohler, Priscila; Kupiec, Tomasz; Linacre, Adrian; Minawi, Anglika; Morling, Niels; Nilsson, Helena; Norén, Lina; Ottens, Renée; Palo, Jukka U; Parson, Walther; Pascali, Vincenzo L; Phillips, Chris; Porto, Maria João; Sajantila, Antti; Schneider, Peter M; Sijen, Titia; Söchtig, Jens; Syndercombe-Court, Denise; Tillmar, Andreas; Turanska, Martina; Vallone, Peter M; Zatkalíková, Lívia; Zidkova, Anastassiya; Branicki, Wojciech; Kayser, Manfred

    2014-07-01

    The IrisPlex system is a DNA-based test system for the prediction of human eye colour from biological samples and consists of a single forensically validated multiplex genotyping assay together with a statistical prediction model that is based on genotypes and phenotypes from thousands of individuals. IrisPlex predicts blue and brown human eye colour with, on average, >94% precision accuracy using six of the currently most eye colour informative single nucleotide polymorphisms (HERC2 rs12913832, OCA2 rs1800407, SLC24A4 rs12896399, SLC45A2 (MATP) rs16891982, TYR rs1393350, and IRF4 rs12203592) according to a previous study, while the accuracy in predicting non-blue and non-brown eye colours is considerably lower. In an effort to vigorously assess the IrisPlex system at the international level, testing was performed by 21 laboratories in the context of a collaborative exercise divided into three tasks and organised by the European DNA Profiling (EDNAP) Group of the International Society of Forensic Genetics (ISFG). Task 1 involved the assessment of 10 blood and saliva samples provided on FTA cards by the organising laboratory together with eye colour phenotypes; 99.4% of the genotypes were correctly reported and 99% of the eye colour phenotypes were correctly predicted. Task 2 involved the assessment of 5 DNA samples extracted by the host laboratory from simulated casework samples, artificially degraded, and provided to the participants in varying DNA concentrations. For this task, 98.7% of the genotypes were correctly determined and 96.2% of eye colour phenotypes were correctly inferred. For Tasks 1 and 2 together, 99.2% (1875) of the 1890 genotypes were correctly generated and of the 15 (0.8%) incorrect genotype calls, only 2 (0.1%) resulted in incorrect eye colour phenotypes. The voluntary Task 3 involved participants choosing their own test subjects for IrisPlex genotyping and eye colour phenotype inference, while eye photographs were provided to the organising

  4. Effect of the incidence angle to free space optical communication based on cat-eye modulating retro-reflector

    NASA Astrophysics Data System (ADS)

    Zhang, Lai-xian; Sun, Hua-yan; Zhao, Yan-zhong; Zheng, Yong-hui; Shan, Cong-miao

    2013-08-01

    Based on the cat-eye effect of optical system, free space optical communication based on cat-eye modulating retro-reflector can build communication link rapidly. Compared to classical free space optical communication system, system based on cat-eye modulating retro-reflector has great advantages such as building communication link more rapidly, a passive terminal is smaller, lighter and lower power consuming. The incident angle is an important factor of cat-eye effect, so it will affect the retro-reflecting communication link. In this paper, the principle and work flow of free space optical communication based on cat-eye modulating retro-reflector were introduced. Then, using the theory of geometric optics, the equivalent model of modulating retro-reflector with incidence angle was presented. The analytical solution of active area and retro-reflected light intensity of cat-eye modulating retro-reflector were given. Noise of PIN photodetector was analyzed, based on which, bit error rate of free space optical communication based on cat-eye modulating retro-reflector was presented. Finally, simulations were done to study the effect of incidence angle to the communication. The simulation results show that the incidence angle has little effect on active area and retro-reflected light intensity when the incidence beam is in the active field angle of cat-eye modulating retro-reflector. With certain system and condition, the communication link can rapidly be built when the incidence light beam is in the field angle, and the bit error rate increases greatly with link range. When link range is smaller than 35Km, the bit error rate is less than 10-16.

  5. Dew inspired breathing-based detection of genetic point mutation visualized by naked eye

    NASA Astrophysics Data System (ADS)

    Xie, Liping; Wang, Tongzhou; Huang, Tianqi; Hou, Wei; Huang, Guoliang; Du, Yanan

    2014-09-01

    A novel label-free method based on breathing-induced vapor condensation was developed for detection of genetic point mutation. The dew-inspired detection was realized by integration of target-induced DNA ligation with rolling circle amplification (RCA). The vapor condensation induced by breathing transduced the RCA-amplified variances in DNA contents into visible contrast. The image could be recorded by a cell phone for further or even remote analysis. This green assay offers a naked-eye-reading method potentially applied for point-of-care liver cancer diagnosis in resource-limited regions.

  6. SU-E-I-37: Eye Lens Dose Reduction From CT Scan Using Organ Based Tube Current Modulation

    SciTech Connect

    Liu, H; Liu, T; Xu, X; Wu, J; Zhuo, W

    2015-06-15

    Purpose: To investigate the eye lens dose reduction by CT scan with organ based tube current modulation (OBTCM) using GPU Monte Carlo code ARCHER-CT. Methods: 36 X-ray sources and bowtie filters were placed around the patient head with the projection angle interval of 10° for one rotation of CT scan, each projection was simulated respectively. The voxel eye models with high resolution(0.1mm*0.1mm*0.1mm) were used in the simulation and different tube voltage including 80kVp, 100kVp, 120kVp and 140kVp were taken into consideration. Results: The radiation doses to the eye lens increased with the tube voltage raised from 80kVp to 140kVp, and the dose results from 0° (AP) direction are much higher than those from 180° (PA) direction for all the 4 different tube voltage investigated. This 360° projection dose characteristic enables organ based TCM, which can reduce the eye lens dose by more than 55%. Conclusion: As the eye lens belongs to superficial tissues, its radiation dose to external exposure like CT is direction sensitive, and this characteristic feature makes organ based TCM to be an effective way to reduce the eye lens dose, so more clinical use of this technique were recommended. National Nature Science Foundation of China(No.11475047)

  7. A Fuzzy-Based Fusion Method of Multimodal Sensor-Based Measurements for the Quantitative Evaluation of Eye Fatigue on 3D Displays

    PubMed Central

    Bang, Jae Won; Choi, Jong-Suk; Heo, Hwan; Park, Kang Ryoung

    2015-01-01

    With the rapid increase of 3-dimensional (3D) content, considerable research related to the 3D human factor has been undertaken for quantitatively evaluating visual discomfort, including eye fatigue and dizziness, caused by viewing 3D content. Various modalities such as electroencephalograms (EEGs), biomedical signals, and eye responses have been investigated. However, the majority of the previous research has analyzed each modality separately to measure user eye fatigue. This cannot guarantee the credibility of the resulting eye fatigue evaluations. Therefore, we propose a new method for quantitatively evaluating eye fatigue related to 3D content by combining multimodal measurements. This research is novel for the following four reasons: first, for the evaluation of eye fatigue with high credibility on 3D displays, a fuzzy-based fusion method (FBFM) is proposed based on the multimodalities of EEG signals, eye blinking rate (BR), facial temperature (FT), and subjective evaluation (SE); second, to measure a more accurate variation of eye fatigue (before and after watching a 3D display), we obtain the quality scores of EEG signals, eye BR, FT and SE; third, for combining the values of the four modalities we obtain the optimal weights of the EEG signals BR, FT and SE using a fuzzy system based on quality scores; fourth, the quantitative level of the variation of eye fatigue is finally obtained using the weighted sum of the values measured by the four modalities. Experimental results confirm that the effectiveness of the proposed FBFM is greater than other conventional multimodal measurements. Moreover, the credibility of the variations of the eye fatigue using the FBFM before and after watching the 3D display is proven using a t-test and descriptive statistical analysis using effect size. PMID:25961382

  8. Is ophthalmology evidence based? A clinical audit of the emergency unit of a regional eye hospital

    PubMed Central

    Lai, T Y Y; Wong, V W Y; Leung, G M

    2003-01-01

    Aim: To evaluate the proportion of interventions that are evidence based in the acute care unit of a regional eye hospital. Methods: A prospective clinical audit was carried out at Hong Kong Eye Hospital in July 2002 to investigate the extent to which ophthalmic practices were evidence based. The major diagnosis and intervention provided were identified through chart review. A corresponding literature search using Medline and the Cochrane Library was performed to assess the degree to which each intervention was based on current, best evidence. Each diagnosis intervention pair was accordingly analysed and graded. The level of best, current evidence supporting each intervention was graded and analysed. Results: A total of 274 consecutive consultation episodes were examined. 22 cases were excluded since no diagnosis or intervention was made during the consultation. 108 (42.9%) patient interventions were found to be based on evidence from systematic reviews, meta-analyses, or randomised controlled trials (RCT). Evidence from prospective or retrospective observational studies supported the interventions in 86 (34.1%) patients. In 58 (23.0%) cases, no evidence or opposing evidence was found regarding the intervention. The proportion of evidence based on RCT or systematic reviews was higher for surgical interventions compared with non-surgical interventions (p=0.007). The proportion of interventions based on RCT or systematic reviews was higher for specialist ophthalmologists than trainee ophthalmologists (p=0.021). Conclusion: This study demonstrated that the majority of interventions in the ophthalmic unit were evidence based and comparable to the experience of other specialties. PMID:12642295

  9. Biological diversity, dietary diversity, and eye health in developing country populations: establishing the evidence-base.

    PubMed

    Bélanger, Julie; Johns, Timothy

    2008-09-01

    Human and ecosystem health converge around biological diversity issues. Cultivated and wild plants as food and medicine make essential contributions to human health, which in turn provides rationales for conservation. While wild and cultivated plant diversity reasonably facilitates dietary diversity and positive health outcomes, the challenges of demonstrating this relationship limit its impact in concept, policy, and practice. We present a rationale for testing the dietary contribution of biological diversity to improved eye health as a case study based on existing phytochemical, pharmacological, and clinical knowledge. We consider the empirical evidence needed to substantiate, interpret, and apply this relationship at a population and ecosystem level within a unified research framework. Epidemiological data strongly support the prevention of childhood vitamin A deficiency blindness, cataract, and age-related macular degeneration by fruit and vegetable consumption. Phytonutrients, including the carotenoids lutein and zeaxanthin, protect the eye from oxidative stress and harmful light exposure. Laboratory, community, and population level research should prioritize food composition of dietary plants from both agriculture and the wild. Intervention studies, focus groups, and transmission of knowledge of local species and varieties within communities will further interpretation of epidemiological data. Population-based studies combining clinical data and measures of access and consumption of biological diversity are key to demonstrating the important relationships among biodiversity, dietary diversity, and health outcomes.

  10. Graphene-Based Bioinspired Compound Eyes for Programmable Focusing and Remote Actuation.

    PubMed

    Wang, Lanlan; Li, Fang; Liu, Hongzhong; Jiang, Weitao; Niu, Dong; Li, Rui; Yin, Lei; Shi, Yongsheng; Chen, Bangdao

    2015-09-30

    Inspired by creatures' eyes, bioinspired compound eyes (BCEs) endowed with larger fields of view and vari-focal capability are extremely appealing in micro-optical devices. However, the present actuation strategies of BCEs commonly demand complicated fields, e.g., electro-wetting actuation, dielectrophoretic drive and pressure gradient, which greatly limits their practical applications. In this work, the photothermal conversion of graphene nanosheets (GNSs) is first utilized to fabricate lenslets toward BCEs. Under the actuation of near-infrared (nIR) pulsed laser, GNSs absorb photo energy and convert it to thermal energy, which increases the temperature of lenslets and then leads to the adjustment of lenslet curvature. At a result, BCEs manifest a reversible 4-fold zoom and a wide FOV up to 160°. In addition, BCEs also perform the programmable focusing by selectively confining nIR laser to a vari-focal region. In contrast with traditional BCEs, graphene-based BCEs are versatile with wide FOV and vari-focal ability by nIR actuation. Herein, these excellent properties make graphene-based BCEs promising for remote-driven microfluidic devices.

  11. Symmetric Kullback-Leibler Metric Based Tracking Behaviors for Bioinspired Robotic Eyes

    PubMed Central

    Liu, Hengli; Luo, Jun; Wu, Peng; Xie, Shaorong; Li, Hengyu

    2015-01-01

    A symmetric Kullback-Leibler metric based tracking system, capable of tracking moving targets, is presented for a bionic spherical parallel mechanism to minimize a tracking error function to simulate smooth pursuit of human eyes. More specifically, we propose a real-time moving target tracking algorithm which utilizes spatial histograms taking into account symmetric Kullback-Leibler metric. In the proposed algorithm, the key spatial histograms are extracted and taken into particle filtering framework. Once the target is identified, an image-based control scheme is implemented to drive bionic spherical parallel mechanism such that the identified target is to be tracked at the center of the captured images. Meanwhile, the robot motion information is fed forward to develop an adaptive smooth tracking controller inspired by the Vestibuloocular Reflex mechanism. The proposed tracking system is designed to make the robot track dynamic objects when the robot travels through transmittable terrains, especially bumpy environment. To perform bumpy-resist capability under the condition of violent attitude variation when the robot works in the bumpy environment mentioned, experimental results demonstrate the effectiveness and robustness of our bioinspired tracking system using bionic spherical parallel mechanism inspired by head-eye coordination. PMID:27019592

  12. Symmetric Kullback-Leibler Metric Based Tracking Behaviors for Bioinspired Robotic Eyes.

    PubMed

    Liu, Hengli; Luo, Jun; Wu, Peng; Xie, Shaorong; Li, Hengyu

    2015-01-01

    A symmetric Kullback-Leibler metric based tracking system, capable of tracking moving targets, is presented for a bionic spherical parallel mechanism to minimize a tracking error function to simulate smooth pursuit of human eyes. More specifically, we propose a real-time moving target tracking algorithm which utilizes spatial histograms taking into account symmetric Kullback-Leibler metric. In the proposed algorithm, the key spatial histograms are extracted and taken into particle filtering framework. Once the target is identified, an image-based control scheme is implemented to drive bionic spherical parallel mechanism such that the identified target is to be tracked at the center of the captured images. Meanwhile, the robot motion information is fed forward to develop an adaptive smooth tracking controller inspired by the Vestibuloocular Reflex mechanism. The proposed tracking system is designed to make the robot track dynamic objects when the robot travels through transmittable terrains, especially bumpy environment. To perform bumpy-resist capability under the condition of violent attitude variation when the robot works in the bumpy environment mentioned, experimental results demonstrate the effectiveness and robustness of our bioinspired tracking system using bionic spherical parallel mechanism inspired by head-eye coordination.

  13. Eye Injuries

    MedlinePlus

    The structure of your face helps protect your eyes from injury. Still, injuries can damage your eye, sometimes severely enough that you could lose your vision. Most eye injuries are preventable. If you play sports or ...

  14. Eye Cancer

    MedlinePlus

    Cancer of the eye is uncommon. It can affect the outer parts of the eye, such as the eyelid, which are made up ... adults are melanoma and lymphoma. The most common eye cancer in children is retinoblastoma, which starts in ...

  15. Eye Diseases

    MedlinePlus

    ... the back of the eye Macular degeneration - a disease that destroys sharp, central vision Diabetic eye problems ... defense is to have regular checkups, because eye diseases do not always have symptoms. Early detection and ...

  16. Strategy To Fabricate Naked-Eye Readout Ultrasensitive Plasmonic Nanosensor Based on Enzyme Mimetic Gold Nanoclusters.

    PubMed

    Zhao, Qian; Huang, Haowen; Zhang, Lingyang; Wang, Linqian; Zeng, Yunlong; Xia, Xiaodong; Liu, Fengping; Chen, Yi

    2016-01-19

    It is broadly interesting but remains a big challenge to explore nanomaterials-based methods to enable naked-eye observation and determination of ultratrace biomarkers and drugs. In this study, we developed a straightforward and extendable plasmonic nanosensor to enable visually quantitative determination of ultratrace target molecules through combining the use of enzyme-mimetic gold nanoclusters (AuNCs). Starting from sandwiched antibody-antigen (i.e., an analyte)-antibody structure, we conjugated AuNCs on the outer layer antibody to catalyze the decomposition of hydrogen peroxide used to reduce HAuCl4 into gold nanopartilces (AuNPs) for naked eye readout. This strategy is in theory applicable to all immunoreactions available and the protocol proposed to attach AuNCs onto an antibody is suitable to all proteins. The applicability of this type of nanosensor was validated by the determination of various ultratrace analytes such as protein avidin, breast cancer antigen, thyroid hormone, and even methamphetamine (MA), giving a naked-eye-readout limit of detection (LOD), down to 1.0 × 10(-20) M protein avidin, 7.52 × 10(-14) U/mL breast cancer antigen 15-3, 2.0 × 10(-15) mg/mL 3,5,3'-L-triiodothyronine and 2.3 × 10(-18) mg/mL MA. This strategy is thus considered an ultrasensitive way to fabricate plasmonic nanosensors, having wide and invaluable application potential in clinical, biological, and environmental studies, and in food quality control.

  17. Evaluation of helmet-mounted display targeting symbology based on eye tracking technology

    NASA Astrophysics Data System (ADS)

    Wang, Lijing; Wen, Fuzhen; Ma, Caixin; Zhao, Shengchu; Liu, Xiaodong

    2014-06-01

    The purpose of this paper is to find the Target Locator Lines (TLLs) which perform best by contrasting and comparing experiment based on three kinds of TTLs of fighter HMD. 10 university students, male, with an average age of 21-23, corrected visual acuity 1.5, participated in the experiment. In the experiment, head movement data was obtained by TrackIR. The geometric relationship between the coordinates of the real world and coordinates of the visual display was obtained by calculating the distance from viewpoint to midpoint of both eyes and the head movement data. Virtual helmet system simulation experiment environment was created by drawing TLLs of fighter HMD in the flight simulator visual scene. In the experiment, eye tracker was used to record the time and saccade trajectory. The results were evaluated by the duration of the time and saccade trajectory. The results showed that the symbol"locator line with digital vector length indication" cost most time and had the longest length of the saccade trajectory. It is the most ineffective and most unacceptable way. "Locator line with extending head vector length symbol" cost less time and had less length of the saccade trajectory. It is effective and acceptable;"Locator line with reflected vector length symbol" cost the least time and had the least length of the saccade trajectory. It is the most effective and most acceptable way. "Locator line with reflected vector length symbol" performs best. The results will provide reference value for the research of TTLs in future.

  18. HotEye (tm) Based Coordinate Measuring Machine for Forging Industry

    SciTech Connect

    OG Technologies

    2003-06-09

    The objective of this project is to develop a 3 dimensional measurement system for the domestic forging industry based on HotEye{trademark}. This technology will allow high definition camera to accurately image a red hot object. The project marries conventional Coordinate Measurement Machine ''CMM'' technology to HotEye{trademark} technology to permit the accurate measurement of forged parts while they are at high temperature. Being able to take such measurements will dramatically reduce the amount of scrap produced by the domestic forging industry. This industry wastes a significant amount of energy because of the high rate of scrap it produces. OGT will: (1) Develop a 3D measurement sensor head that will work on a part at a temperature up to 1,450 C with an accuracy of 0.1mm or better and with a scanning speed of less than 10 seconds for an area of 100mm x 100mm. (2) Develop a Virtual-Fixturing software package to alleviate the need of precise hard fixturing. (3) Integrate the 3D measurement sensor head and the Virtual-Fixturing software into a standard CMM, both hardware (replacing the probes) and software (data format and user interface match) so that the system can automatically perform a complete preprogrammed measurement of a hot product. (4) Test and evaluate the system in a forging facility.

  19. A Community-based Eye Care Intervention in Southern Egypt: Impact on Trachomatous Trichiasis Surgical Coverage

    PubMed Central

    Mousa, Ahmed; Courtright, Paul; Kazanjian, Arminee; Bassett, Ken

    2015-01-01

    Purpose: The purpose of this study was to measure the impact of a community-based intervention on uptake of trichiasis surgery in Southern Egypt. Methods: Four villages where trachoma is endemic were randomly selected in the Samalout district, Egypt. Two villages were selected for intervention (intervention villages) and two matched villages for nonintervention (nonintervention villages). The intervention model provided community information sessions, door-to-door health education, screening, and improvements in the clinical capacity of eye care providers. The intervention was evaluated through two pre- and post-intervention community-based surveys that included the prevalence of trachoma and the utilization of eye care services at local hospitals. All patients with trichiasis answered a questionnaire regarding surgical utilization and barriers. Results: In the baseline survey, the trachomatous trichiasis (TT) surgical coverage was 22.7% (38.9% males, 16.7% females) in all villages. Following the intervention, the TT surgical coverage increased to 68% in villages that received the intervention (81.5% males, 60% females). Nonintervention villages had a TT surgical coverage of 26.1% (37.5% males, 20% females). In the intervention villages, the prevalence of TT significantly decreased from 9.4% (5.7% males, 11.8% females) to 3.8% (1.9% males, 5.1% females) (P = 0.013), in 2008. In nonintervention villages, there was a slight, but insignificant decrease in TT from 10.1% (3.1% males, 14.4% females) to 8.2% (3% males, 11.5% females) (P = 0.580). The major barriers to uptake of TT surgical services were: “Feeling no problem” (17.3%), “fear of surgery” (12.7%) and “cost” (12.7%). Conclusion: A community-based eye health education program with door-to-door screening significantly increased the uptake of TT surgical services. Although improvements to the delivery of surgical service are essential, they did not lead to any significant improvements in the

  20. The role of the anterior lateral eyes in the vision-based behaviour of jumping spiders.

    PubMed

    Zurek, Daniel B; Taylor, Alan J; Evans, Christopher S; Nelson, Ximena J

    2010-07-15

    Jumping spiders, or salticids, sample their environment using a combination of two types of eyes. The forward-facing pair of 'principal' eyes have narrow fields of view, but exceptional spatial resolution, while the two or three pairs of 'secondary' eyes have wide fields of view and function especially well as motion analysers. Motion detected by the secondary eyes may elicit an orienting response, whereupon the object of interest is examined further using the high-acuity principal eyes. The anterior lateral (AL) eyes are particularly interesting, as they are the only forward-facing pair of secondary eyes. In this study, we aimed to determine characteristics of stimuli that elicit orienting responses mediated by the AL eyes. After covering all eyes except the AL eyes, we measured orienting responses to dot stimuli that varied in size and contrast, and moved at different speeds. We found that all stimulus parameters had significant effects on orientation propensity. When tethered flies were used as prey, we found that visual information from the AL eyes alone was sufficient to elicit stalking behaviour. These results suggest that, in terms of overall visual processing, the relevance of spatial vision in the AL eyes has been underestimated in the literature. Our results also show that female spiders are significantly more responsive than males. We found that hunger caused similar increases in orientation propensity in the two sexes, but females responded more often than males both when sated and when hungry. A higher propensity by females to orient toward moving objects may be related to females tending to experience higher nutritional demands than males. PMID:20581266

  1. A multi level system design for vigilance measurement based on head posture estimation and eyes blinking

    NASA Astrophysics Data System (ADS)

    Teyeb, Ines; Jemai, Olfa; Zaied, Mourad; ben Amar, Chokri

    2015-12-01

    Driving security is an important task for human society. The major challenge in the field of accident avoidance systems is the driver vigilance monitoring. The lack of vigilance can be noticed by various ways, such as, fatigue, drowsiness and distraction. Hence, the need of a reliable driver's vigilance decrease detection system which can alert drivers before a mishap happens. In this paper, we present a novel approach for vigilance estimation based on multilevel system by combining head movement analysis and eyes blinking. We have used Viola and Jones algorithm to analyse head movement and a classification system using wavelet networks for eyelid closure measuring. The contribution of our application is classifiying the vigilance state at multi level. This is different from the binary-class (awakening or hypovigilant state) existing in most popular systems.

  2. Similarity-Based Interference During Language Comprehension: Evidence from Eye Tracking During Reading

    PubMed Central

    Gordon, Peter C.; Hendrick, Randall; Johnson, Marcus; Lee, Yoonhyoung

    2006-01-01

    The nature of working memory operation during complex sentence comprehension was studied using eye-tracking methodology. Readers had difficulty when the syntax of a sentence required them to hold two similar noun phrases (NPs) in working memory before syntactically and semantically integrating either of the NPs with a verb. In sentence structures that placed these NPs at the same linear distances from one another but allowed integration with a verb for one of the NPs, the comprehension difficulty was not seen. These results are interpreted as indicating that similarity-based interference occurs online during the comprehension of complex sentences and that the degree of memory accessibility conventionally associated with different types of NPs does not have a strong effect on sentence processing. PMID:17087585

  3. High-speed, image-based eye tracking with a scanning laser ophthalmoscope

    PubMed Central

    Sheehy, Christy K.; Yang, Qiang; Arathorn, David W.; Tiruveedhula, Pavan; de Boer, Johannes F.; Roorda, Austin

    2012-01-01

    We demonstrate a high-speed, image-based tracking scanning laser ophthalmoscope (TSLO) that can provide high fidelity structural images, real-time eye tracking and targeted stimulus delivery. The system was designed for diffraction-limited performance over an 8° field of view (FOV) and operates with a flexible field of view of 1°–5.5°. Stabilized videos of the retina were generated showing an amplitude of motion after stabilization of 0.2 arcmin or less across all frequencies. In addition, the imaging laser can be modulated to place a stimulus on a targeted retinal location. We show a stimulus placement accuracy with a standard deviation less than 1 arcmin. With a smaller field size of 2°, individual cone photoreceptors were clearly visible at eccentricities outside of the fovea. PMID:23082300

  4. Similarity-based interference during language comprehension: Evidence from eye tracking during reading.

    PubMed

    Gordon, Peter C; Hendrick, Randall; Johnson, Marcus; Lee, Yoonhyoung

    2006-11-01

    The nature of working memory operation during complex sentence comprehension was studied by means of eye-tracking methodology. Readers had difficulty when the syntax of a sentence required them to hold 2 similar noun phrases (NPs) in working memory before syntactically and semantically integrating either of the NPs with a verb. In sentence structures that placed these NPs at the same linear distances from one another but allowed integration with a verb for 1 of the NPs, the comprehension difficulty was not seen. These results are interpreted as indicating that similarity-based interference occurs online during the comprehension of complex sentences and that the degree of memory accessibility conventionally associated with different types of NPs does not have a strong effect on sentence processing.

  5. A novel lobster-eye imaging system based on Schmidt-type objective for X-ray-backscattering inspection.

    PubMed

    Xu, Jie; Wang, Xin; Zhan, Qi; Huang, Shengling; Chen, Yifan; Mu, Baozhong

    2016-07-01

    This paper presents a novel lobster-eye imaging system for X-ray-backscattering inspection. The system was designed by modifying the Schmidt geometry into a treble-lens structure in order to reduce the resolution difference between the vertical and horizontal directions, as indicated by ray-tracing simulations. The lobster-eye X-ray imaging system is capable of operating over a wide range of photon energies up to 100 keV. In addition, the optics of the lobster-eye X-ray imaging system was tested to verify that they meet the requirements. X-ray-backscattering imaging experiments were performed in which T-shaped polymethyl-methacrylate objects were imaged by the lobster-eye X-ray imaging system based on both the double-lens and treble-lens Schmidt objectives. The results show similar resolution of the treble-lens Schmidt objective in both the vertical and horizontal directions. Moreover, imaging experiments were performed using a second treble-lens Schmidt objective with higher resolution. The results show that for a field of view of over 200 mm and with a 500 mm object distance, this lobster-eye X-ray imaging system based on a treble-lens Schmidt objective offers a spatial resolution of approximately 3 mm.

  6. A novel lobster-eye imaging system based on Schmidt-type objective for X-ray-backscattering inspection

    NASA Astrophysics Data System (ADS)

    Xu, Jie; Wang, Xin; Zhan, Qi; Huang, Shengling; Chen, Yifan; Mu, Baozhong

    2016-07-01

    This paper presents a novel lobster-eye imaging system for X-ray-backscattering inspection. The system was designed by modifying the Schmidt geometry into a treble-lens structure in order to reduce the resolution difference between the vertical and horizontal directions, as indicated by ray-tracing simulations. The lobster-eye X-ray imaging system is capable of operating over a wide range of photon energies up to 100 keV. In addition, the optics of the lobster-eye X-ray imaging system was tested to verify that they meet the requirements. X-ray-backscattering imaging experiments were performed in which T-shaped polymethyl-methacrylate objects were imaged by the lobster-eye X-ray imaging system based on both the double-lens and treble-lens Schmidt objectives. The results show similar resolution of the treble-lens Schmidt objective in both the vertical and horizontal directions. Moreover, imaging experiments were performed using a second treble-lens Schmidt objective with higher resolution. The results show that for a field of view of over 200 mm and with a 500 mm object distance, this lobster-eye X-ray imaging system based on a treble-lens Schmidt objective offers a spatial resolution of approximately 3 mm.

  7. A novel lobster-eye imaging system based on Schmidt-type objective for X-ray-backscattering inspection.

    PubMed

    Xu, Jie; Wang, Xin; Zhan, Qi; Huang, Shengling; Chen, Yifan; Mu, Baozhong

    2016-07-01

    This paper presents a novel lobster-eye imaging system for X-ray-backscattering inspection. The system was designed by modifying the Schmidt geometry into a treble-lens structure in order to reduce the resolution difference between the vertical and horizontal directions, as indicated by ray-tracing simulations. The lobster-eye X-ray imaging system is capable of operating over a wide range of photon energies up to 100 keV. In addition, the optics of the lobster-eye X-ray imaging system was tested to verify that they meet the requirements. X-ray-backscattering imaging experiments were performed in which T-shaped polymethyl-methacrylate objects were imaged by the lobster-eye X-ray imaging system based on both the double-lens and treble-lens Schmidt objectives. The results show similar resolution of the treble-lens Schmidt objective in both the vertical and horizontal directions. Moreover, imaging experiments were performed using a second treble-lens Schmidt objective with higher resolution. The results show that for a field of view of over 200 mm and with a 500 mm object distance, this lobster-eye X-ray imaging system based on a treble-lens Schmidt objective offers a spatial resolution of approximately 3 mm. PMID:27475544

  8. From a Bird's Eye View to a Worm's Eye View: A Comprehension-Based Program of Foreign Language Instruction.

    ERIC Educational Resources Information Center

    Manning, Phyllis J.

    The language teaching method presented here is an inter-related set of techniques for teaching target comprehension skills directly to students on both university and high school levels. Three elements of the method are discussed: (1) the basics of a comprehension-based classroom; (2) the expanded speaking component; and (3) the expanded reading…

  9. Etiology and Features of Eyes with Rubeosis Iridis among Korean Patients: A Population-Based Single Center Study

    PubMed Central

    Jeong, Yun Cheol; Hwang, Young Hoon

    2016-01-01

    Purpose To estimate the etiology and features of the eyes with rubeosis iridis among Korean patients. Materials and Methods This study is a retrospective review of 533 Korean patients with rubeosis iridis who visited an eye hospital in Seoul, Korea. We defined rubeosis iridis as visible blood vessels on the iris surface detected during a slit-lamp examination. All cases were reviewed for age at the time of diagnosis, medical history, the most likely cause of rubeosis iridis, visual acuity, and intraocular pressure. Results The most commonly observed cause of rubeosis iridis was diabetic retinopathy (DR; n = 337, 63.2%), followed by retinal vein occlusion (RVO; n = 101, 18.9%), ocular ischemic syndrome (OIS; n = 24, 4.5%), retinal detachment (n = 17, 3.2%), and uveitis (n = 15, 2.8%). The cause was classified as miscellaneous in 18 cases (3.4%); in 21 eyes (3.9%), the cause was not clear. Age at the time of rubeosis iridis diagnosis was lower in patients with DR (56.5 years) than in those with RVO (61.0 years) and OIS (64.8 years; P < 0.01). Intraocular pressure of the eyes with DR (37.3 mmHg) and RVO (39.5 mmHg) was higher than that of the eyes with OIS (25.8 mmHg; P < 0.01). Conclusion In our population-based single center study, DR was the leading cause of rubeosis iridis followed by RVO and OIS among Korean patients. The clinical characteristics of the eyes with rubeosis iridis differed according to etiology. This finding may be useful when assessing eyes with rubeosis iridis. PMID:27490797

  10. Structure Modulates Similarity-Based Interference in Sluicing: An Eye Tracking study.

    PubMed

    Harris, Jesse A

    2015-01-01

    In cue-based content-addressable approaches to memory, a target and its competitors are retrieved in parallel from memory via a fast, associative cue-matching procedure under a severely limited focus of attention. Such a parallel matching procedure could in principle ignore the serial order or hierarchical structure characteristic of linguistic relations. I present an eye tracking while reading experiment that investigates whether the sentential position of a potential antecedent modulates the strength of similarity-based interference, a well-studied effect in which increased similarity in features between a target and its competitors results in slower and less accurate retrieval overall. The manipulation trades on an independently established Locality bias in sluiced structures to associate a wh-remnant (which ones) in clausal ellipsis with the most local correlate (some wines), as in The tourists enjoyed some wines, but I don't know which ones. The findings generally support cue-based parsing models of sentence processing that are subject to similarity-based interference in retrieval, and provide additional support to the growing body of evidence that retrieval is sensitive to both the structural position of a target antecedent and its competitors, and the specificity or diagnosticity of retrieval cues.

  11. Structure Modulates Similarity-Based Interference in Sluicing: An Eye Tracking study.

    PubMed

    Harris, Jesse A

    2015-01-01

    In cue-based content-addressable approaches to memory, a target and its competitors are retrieved in parallel from memory via a fast, associative cue-matching procedure under a severely limited focus of attention. Such a parallel matching procedure could in principle ignore the serial order or hierarchical structure characteristic of linguistic relations. I present an eye tracking while reading experiment that investigates whether the sentential position of a potential antecedent modulates the strength of similarity-based interference, a well-studied effect in which increased similarity in features between a target and its competitors results in slower and less accurate retrieval overall. The manipulation trades on an independently established Locality bias in sluiced structures to associate a wh-remnant (which ones) in clausal ellipsis with the most local correlate (some wines), as in The tourists enjoyed some wines, but I don't know which ones. The findings generally support cue-based parsing models of sentence processing that are subject to similarity-based interference in retrieval, and provide additional support to the growing body of evidence that retrieval is sensitive to both the structural position of a target antecedent and its competitors, and the specificity or diagnosticity of retrieval cues. PMID:26733893

  12. Structure Modulates Similarity-Based Interference in Sluicing: An Eye Tracking study

    PubMed Central

    Harris, Jesse A.

    2015-01-01

    In cue-based content-addressable approaches to memory, a target and its competitors are retrieved in parallel from memory via a fast, associative cue-matching procedure under a severely limited focus of attention. Such a parallel matching procedure could in principle ignore the serial order or hierarchical structure characteristic of linguistic relations. I present an eye tracking while reading experiment that investigates whether the sentential position of a potential antecedent modulates the strength of similarity-based interference, a well-studied effect in which increased similarity in features between a target and its competitors results in slower and less accurate retrieval overall. The manipulation trades on an independently established Locality bias in sluiced structures to associate a wh-remnant (which ones) in clausal ellipsis with the most local correlate (some wines), as in The tourists enjoyed some wines, but I don't know which ones. The findings generally support cue-based parsing models of sentence processing that are subject to similarity-based interference in retrieval, and provide additional support to the growing body of evidence that retrieval is sensitive to both the structural position of a target antecedent and its competitors, and the specificity or diagnosticity of retrieval cues. PMID:26733893

  13. An Examination of Cognitive Processing of Multimedia Information Based on Viewers' Eye Movements

    ERIC Educational Resources Information Center

    Liu, Han-Chin; Chuang, Hsueh-Hua

    2011-01-01

    This study utilized qualitative and quantitative designs and eye-tracking technology to understand how viewers process multimedia information. Eye movement data were collected from eight college students (non-science majors) while they were viewing web pages containing different types of text and illustrations depicting the mechanism of…

  14. Thermal fluctuation based study of aqueous deficient dry eyes by non-invasive thermal imaging.

    PubMed

    Azharuddin, Mohammad; Bera, Sumanta Kr; Datta, Himadri; Dasgupta, Anjan Kr

    2014-03-01

    In this paper we have studied the thermal fluctuation patterns occurring at the ocular surface of the left and right eyes for aqueous deficient dry eye (ADDE) patients and control subjects by thermal imaging. We conducted our experiment on 42 patients (84 eyes) with aqueous deficient dry eyes and compared with 36 healthy volunteers (72 eyes) without any history of ocular surface disorder. Schirmer's test, Tear Break-up Time, tear Meniscus height and fluorescein staining tests were conducted. Ocular surface temperature measurement was done, using an FL-IR thermal camera and thermal fluctuation in left and right eyes was calculated and analyzed using MATLAB. The time series containing the sum of squares of the temperature fluctuation on the ocular surface were compared for aqueous deficient dry eye and control subjects. Significant statistical difference between the fluctuation patterns for control and ADDE was observed (p < 0.001 at 95% confidence interval). Thermal fluctuations in left and right eyes are significantly correlated in controls but not in ADDE subjects. The possible origin of such correlation in control and lack of correlation in the ADDE subjects is discussed in the text.

  15. A Microcomputer-Based Software Package for Eye-Monitoring Research. Technical Report No. 434.

    ERIC Educational Resources Information Center

    McConkie, George W.; And Others

    A software package is described that collects and reduces eye behavior data (eye position and pupil size) using an IBM-PC compatible computer. Written in C language for speed and portability, it includes several features: (1) data can be simultaneously collected from other sources (such as electroencephalography and electromyography); (2)…

  16. Eye gaze performance for children with severe physical impairments using gaze-based assistive technology—A longitudinal study

    PubMed Central

    Borgestig, Maria; Sandqvist, Jan; Parsons, Richard; Falkmer, Torbjörn; Hemmingsson, Helena

    2016-01-01

    ABSTRACT Gaze-based assistive technology (gaze-based AT) has the potential to provide children affected by severe physical impairments with opportunities for communication and activities. This study aimed to examine changes in eye gaze performance over time (time on task and accuracy) in children with severe physical impairments, without speaking ability, using gaze-based AT. A longitudinal study with a before and after design was conducted on 10 children (aged 1–15 years) with severe physical impairments, who were beginners to gaze-based AT at baseline. Thereafter, all children used the gaze-based AT in daily activities over the course of the study. Compass computer software was used to measure time on task and accuracy with eye selection of targets on screen, and tests were performed with the children at baseline, after 5 months, 9–11 months, and after 15–20 months. Findings showed that the children improved in time on task after 5 months and became more accurate in selecting targets after 15–20 months. This study indicates that these children with severe physical impairments, who were unable to speak, could improve in eye gaze performance. However, the children needed time to practice on a long-term basis to acquire skills needed to develop fast and accurate eye gaze performance. PMID:26496529

  17. A new rhodamine-based colorimetric chemosensor for naked-eye detection of Cu2 + in aqueous solution

    NASA Astrophysics Data System (ADS)

    Hu, Yang; Zhang, Jing; Lv, Yuan-Zheng; Huang, Xiao-Huan; Hu, Sheng-li

    2016-03-01

    A new colorimetric probe 1 based on rhodamine B lactam was developed for naked-eye detection of Cu2 +. The optical feature of 1 for Cu2 + was investigated by UV-vis absorption spectroscopy. Upon the addition of Cu2 +, the 1 displayed a distinct color change from colorless to pink, which can be directly detected by the naked eye. The stoichiometry of 1 to Cu2 + complex was found to be 1:1 and the naked-eye detection limit was determined as low as 2 μM. The results suggest that the probe 1 may provide a convenient method for visual detection of Cu2 + with high sensitivity.

  18. A new rhodamine-based colorimetric chemosensor for naked-eye detection of Cu(2+) in aqueous solution.

    PubMed

    Hu, Yang; Zhang, Jing; Lv, Yuan-Zheng; Huang, Xiao-Huan; Hu, Sheng-li

    2016-03-15

    A new colorimetric probe 1 based on rhodamine B lactam was developed for naked-eye detection of Cu(2+). The optical feature of 1 for Cu(2+) was investigated by UV-vis absorption spectroscopy. Upon the addition of Cu(2+), the 1 displayed a distinct color change from colorless to pink, which can be directly detected by the naked eye. The stoichiometry of 1 to Cu(2+) complex was found to be 1:1 and the naked-eye detection limit was determined as low as 2 μM. The results suggest that the probe 1 may provide a convenient method for visual detection of Cu(2+) with high sensitivity.

  19. Is Making a Risky Choice Based on a Weighting and Adding Process? An Eye-Tracking Investigation

    ERIC Educational Resources Information Center

    Su, Yin; Rao, Li-Lin; Sun, Hong-Yue; Du, Xue-Lei; Li, Xingshan; Li, Shu

    2013-01-01

    The debate about whether making a risky choice is based on a weighting and adding process has a long history and is still unresolved. To address this long-standing controversy, we developed a comparative paradigm. Participants' eye movements in 2 risky choice tasks that required participants to choose between risky options in single-play and…

  20. Wide field OCT based microangiography in living human eye (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Zhang, Qinqin; Chen, Chieh-Li; Chu, Zhongdi; Zhang, Anqi; An, Lin; Durbin, Mary; Sharma, Utkarsh; Rosenfeld, Philip J.; Wang, Ruikang K.

    2016-03-01

    To investigate the application of optical microangiography (OMAG) in living human eye. Patients with different macular diseases were recruited, including diabetic retinopathy (DR), geographic atrophy (GA), retinitis pigmentosa (RP), and venous occlusion, et al. Wide field OCT angiography images can be generated by montage scanning protocol based on the tracking system. OMAG algorithm based on complex differentiation was used to extract the blood flow and removed the bulk motion by 2D cross-correlation method. The 3D angiography was segmented into 3 layers in the retina and 2 layers in the choroid. The en-face maximum projection was used to obtain 2-dimensional angiograms of different layers coded with different colors. Flow and structure images were combined for cross-sectional view. En face OMAG images of different macular diseases showed a great agreement with FA. Meanwhile, OMAG gave more distinct vascular network visions that were less affected by hemorrhage and leakage. The MAs were observed in both superficial and middle retinal layers based on OMAG angiograms in different layers of DR patients. The contour line of FAZ was extracted as well, which can be quantitative the retinal diseases. For GA patient, the damage of RPE layer enhanced the penetration of light and enabled the acquisition of choriocapillaries and choroidal vessels. The wide field OMAG angiogram enabled the capability of capturing the entire geographic atrophy. OMAG provides depth-resolved information and detailed vascular images of DR and GA patients, providing a better visualization of vascular network compared to FA.

  1. Optic Disc Perfusion in Primary Open Angle and Normal Tension Glaucoma Eyes Using Optical Coherence Tomography-Based Microangiography

    PubMed Central

    Wen, Joanne C.; Zhang, Qinqin; Xin, Chen; Gupta, Divakar; Mudumbai, Raghu C.; Johnstone, Murray A.; Wang, Ruikang K.; Chen, Philip P.

    2016-01-01

    Purpose To investigate optic disc perfusion differences in normal, primary open-angle glaucoma (POAG), and normal tension glaucoma (NTG) eyes using optical microangiography (OMAG) based optical coherence tomography (OCT) angiography technique. Design Cross-sectional, observational study. Subjects Twenty-eight normal, 30 POAG, and 31 NTG subjects. Methods One eye from each subject was scanned with a 68 kHz Cirrus HD-OCT 5,000-based OMAG prototype system centered at the optic nerve head (ONH) (Carl Zeiss Meditec Inc, Dublin, CA). Microvascular images were generated from the OMAG dataset by detecting the differences in OCT signal between consecutive B-scans. The pre-laminar layer (preLC) was isolated by a semi-automatic segmentation program. Main Outcome Measures Optic disc perfusion, quantified as flux, vessel area density, and normalized flux (flux normalized by the vessel area) within the ONH. Results Glaucomatous eyes had significantly lower optic disc perfusion in preLC in all three perfusion metrics (p<0.0001) compared to normal eyes. The visual field (VF) mean deviation (MD) and pattern standard deviation (PSD) were similar between the POAG and NTG groups, and no differences in optic disc perfusion were observed between POAG and NTG. Univariate analysis revealed significant correlation between optic disc perfusion and VF MD, VF PSD, and rim area in both POAG and NTG groups (p≤0.0288). However, normalized optic disc perfusion was correlated with some structural measures (retinal nerve fiber layer thickness and ONH cup/disc ratio) only in POAG eyes. Conclusions Optic disc perfusion detected with OMAG was significantly reduced in POAG and NTG groups compared to normal controls, but no difference was seen between POAG and NTG groups with similar levels of VF damage. Disc perfusion was significantly correlated with VF MD, VF PSD, and rim area in glaucomatous eyes. Vascular changes at the optic disc as measured using OMAG may provide useful information for

  2. Eye detection based on head contour geometry and wavelet subband projection

    NASA Astrophysics Data System (ADS)

    Wang, Jing-Weing; Chen, Wen-Yuan

    2006-05-01

    We propose a novel two-step approach for eyes detection in complex scenes including both indoor and outdoor environments. This approach adopts face localization to eye extraction strategy. First, we use energy analysis to remove most noise-like regions to enhance face localization performance, and then use the head contour detection (HCD) approach to search for the best combinations of facial sides and head contours with an anthropometric measure, and thereafter the face-of-interest (FOI) region is located. In the meantime, via the deedging preprocessing for facial sides, a wavelet subband interorientation projection method is adopted to select eye-like candidates. Along with the geometric discrimination among the facial components, such as the eyes, nose, and mouth, this eye verification rule verifies the selected eyes candidates. The eye positions are then marked and refined by the bounding box of FOI region as the ellipse being the best fit of the facial oval shape. The experimental results demonstrate that the performance of our proposed method has significant improvement compared to others on three head-and-shoulder databases.

  3. Neural bases of eye and gaze processing: The core of social cognition

    PubMed Central

    Itier, Roxane J.; Batty, Magali

    2014-01-01

    Eyes and gaze are very important stimuli for human social interactions. Recent studies suggest that impairments in recognizing face identity, facial emotions or in inferring attention and intentions of others could be linked to difficulties in extracting the relevant information from the eye region including gaze direction. In this review, we address the central role of eyes and gaze in social cognition. We start with behavioral data demonstrating the importance of the eye region and the impact of gaze on the most significant aspects of face processing. We review neuropsychological cases and data from various imaging techniques such as fMRI/PET and ERP/MEG, in an attempt to best describe the spatio-temporal networks underlying these processes. The existence of a neuronal eye detector mechanism is discussed as well as the links between eye gaze and social cognition impairments in autism. We suggest impairments in processing eyes and gaze may represent a core deficiency in several other brain pathologies and may be central to abnormal social cognition. PMID:19428496

  4. Monitoring eye movement with a computer based Electro-oculogram (EOG).

    PubMed

    Dibble, Jamie M; Teters, Cherish K

    2004-01-01

    This project investigated ways to improve retinal laser surgery techniques. Currently, the surgery is manual and not very accurate because the eye has a tendency to move involuntarily and the laser can cause permanent damage to the patient if the eye moves out of range. Therefore, an Electro-oculogram (EOG) system was designed and tested capable of recording eye movement in both horizontal and vertical directions using the voltages produced by the eye for the purpose of feedback to the surgeon. The EOG system consisted of various filters and amplifiers to amplify the small signals created by the eye, which were obtained using surface electrodes placed around the eyes. An LED board was also designed for the subject to follow various LED lights with his/her eyes in all directions. A program was written with LabView software that was used to control the LED board as well as record and analyze the EOG signals. MatLab was used in correlation with LabView to perform additional filtering and to find the mean, root square mean, and standard deviation of the signal. This data was used to determine if a relationship exists between the direction of eye movement and the voltage produced by the eye. The EOG system and LED board operated as expected and the LabView program was capable of recording and analyzing the signals. The information gathered from this project could make retinal laser surgery more precise and safer by alleviating the potential for error and therefore unintentional damage to the patient. PMID:15134002

  5. Healthy Eyes

    MedlinePlus

    ... please turn Javascript on. Healthy Eyes Maintaining Your Vision Click for more information Taking good care of ... are qualified to perform eye exams. Aging and Vision Changes As you age, it is normal to ...

  6. Eye Anatomy

    MedlinePlus

    ... News About Us Donate In This Section Eye Anatomy en Español email Send this article to a ... You at Risk For Glaucoma? Childhood Glaucoma Eye Anatomy Five Common Glaucoma Tests Glaucoma Facts and Stats ...

  7. Your Eyes

    MedlinePlus

    ... the eye and keeps it healthy. previous continue Light, Lens, Action These next parts are really cool, ... the eye. previous continue Rods and Cones Process Light The retina uses special cells called rods and ...

  8. A noninvasive video-based method for measuring lens transmission properties of the human eye.

    PubMed

    Johnson, C A; Howard, D L; Marshall, D; Shu, H

    1993-11-01

    The Lens Absorption Monitor (LAM) is an automated video-based system for obtaining rapid objective noninvasive measurements of the spectral transmission properties of the human lens. The technique is based on intensity measurements of the 4th Purkinje image for different wavelengths, and incorporates several features that overcome some of the difficulties associated with previous studies using this approach. LAM transmission measures for the visible spectrum can be obtained in approximately 2 s, and in most instances can be obtained without having to dilate the subject's eye. This paper describes the technique and presents our initial findings for 40 normal observers between the ages of 24 and 77 years. Results of the LAM technique show that it is able to measure the wavelength-dependent properties of the lens accurately and to identify age-related changes in "yellowing" of the lens. Test-retest reliability of the LAM is better than for psychophysical estimates of ocular media transmission. LAM and psychophysical measures in the same subjects were found to be correlated, although LAM measures produced consistently lower values of lens density than the psychophysical determinations. There was only moderate agreement between LAM and psychophysical measures of lens density. Possible explanations for these differences are discussed. Future research will determine whether this technique is able to detect and quantify early cataract development.

  9. A neural model of the frontal eye fields with reward-based learning.

    PubMed

    Ye, Weijie; Liu, Shenquan; Liu, Xuanliang; Yu, Yuguo

    2016-09-01

    Decision-making is a flexible process dependent on the accumulation of various kinds of information; however, the corresponding neural mechanisms are far from clear. We extended a layered model of the frontal eye field to a learning-based model, using computational simulations to explain the cognitive process of choice tasks. The core of this extended model has three aspects: direction-preferred populations that cluster together the neurons with the same orientation preference, rule modules that control different rule-dependent activities, and reward-based synaptic plasticity that modulates connections to flexibly change the decision according to task demands. After repeated attempts in a number of trials, the network successfully simulated three decision choice tasks: an anti-saccade task, a no-go task, and an associative task. We found that synaptic plasticity could modulate the competition of choices by suppressing erroneous choices while enhancing the correct (rewarding) choice. In addition, the trained model captured some properties exhibited in animal and human experiments, such as the latency of the reaction time distribution of anti-saccades, the stop signal mechanism for canceling a reflexive saccade, and the variation of latency to half-max selectivity. Furthermore, the trained model was capable of reproducing the re-learning procedures when switching tasks and reversing the cue-saccade association. PMID:27284696

  10. The Effectiveness of Panoramic Maps Design: a Preliminary Study Based on Mobile Eye-Tracking

    NASA Astrophysics Data System (ADS)

    Balzarini, R.; Murat, M.

    2016-06-01

    This paper presents preliminary results from an ongoing research based on the study of visual attention through mobile eye-tracking techniques. The visual-cognitive approach investigates the reading-comprehension of a particular territorial representation: ski trails maps. The general issue of the study is to provide insights about the effectiveness of panoramic ski maps and more broadly, to suggest innovative efficient representation of the geographic information in mountain. According to some mountain operators, the information provided by paper ski maps no longer meets the needs of a large part of the customers; the question now arises of their adaptation to new digital practices (iPhone, tablets). In a computerized process perspective, this study particularly focuses on the representations, and the inferred information, which are really helpful to the users-skiers to apprehend the territory and make decisions, and which could be effectively replicated into a digital system. The most interesting output relies on the relevance of the panorama view: panorama still fascinates, but contrary to conventional wisdom, the information it provides does not seem to be useful to the skier. From a socio-historical perspective this study shows how empirical evidence-based approach can support the change: our results enhance the discussion on the effectiveness of the message that mountain operators want to convey to the tourist and therefore, on the renewal of (geographical) information in ski resorts.

  11. Updating OSHA Standards Based on National Consensus Standards; Eye and Face Protection. Final rule.

    PubMed

    2016-03-25

    On March 13, 2015, OSHA published in the Federal Register a notice of proposed rulemaking (NPRM) to revise its eye and face protection standards for general industry, shipyard employment, marine terminals, longshoring, and construction by updating the references to national consensus standards approved by the American National Standards Institute (ANSI). OSHA received no significant objections from commenters and therefore is adopting the amendments as proposed. This final rule updates the references in OSHA's eye and face standards to reflect the most recent edition of the ANSI/International Safety Equipment Association (ISEA) eye and face protection standard. It removes the oldest-referenced edition of the same ANSI standard. It also amends other provisions of the construction eye and face protection standard to bring them into alignment with OSHA's general industry and maritime standards. PMID:27017630

  12. A model of visually-guided smooth pursuit eye movements based on behavioral observations.

    PubMed

    Krauzlis, R J; Lisberger, S G

    1994-12-01

    We report a model that reproduces many of the behavioral properties of smooth pursuit eye movements. The model is a negative-feedback system that uses three parallel visual motion pathways to drive pursuit. The three visual pathways process image motion, defined as target motion with respect to the moving eye, and provide signals related to image velocity, image acceleration, and a transient that occurs at the onset of target motion. The three visual motion signals are summed and integrated to produce the eye velocity output of the model. The model reproduces the average eye velocity evoked by steps of target velocity in monkeys and humans and accounts for the variation among individual responses and subjects. When its motor pathways are expanded to include positive feedback of eye velocity and a "switch", the model reproduces the exponential decay in eye velocity observed when a moving target stops. Manipulation of this expanded model can mimic the effects of stimulation and lesions in the arcuate pursuit area, the middle temporal visual area (MT), and the medial superior temporal visual area (MST).

  13. Role of muscle pulleys in producing eye position-dependence in the angular vestibuloocular reflex: a model-based study

    NASA Technical Reports Server (NTRS)

    Thurtell, M. J.; Kunin, M.; Raphan, T.; Wall, C. C. (Principal Investigator)

    2000-01-01

    It is well established that the head and eye velocity axes do not always align during compensatory vestibular slow phases. It has been shown that the eye velocity axis systematically tilts away from the head velocity axis in a manner that is dependent on eye-in-head position. The mechanisms responsible for producing these axis tilts are unclear. In this model-based study, we aimed to determine whether muscle pulleys could be involved in bringing about these phenomena. The model presented incorporates semicircular canals, central vestibular pathways, and an ocular motor plant with pulleys. The pulleys were modeled so that they brought about a rotation of the torque axes of the extraocular muscles that was a fraction of the angle of eye deviation from primary position. The degree to which the pulleys rotated the torque axes was altered by means of a pulley coefficient. Model input was head velocity and initial eye position data from passive and active yaw head impulses with fixation at 0 degrees, 20 degrees up and 20 degrees down, obtained from a previous experiment. The optimal pulley coefficient required to fit the data was determined by calculating the mean square error between data and model predictions of torsional eye velocity. For active head impulses, the optimal pulley coefficient varied considerably between subjects. The median optimal pulley coefficient was found to be 0.5, the pulley coefficient required for producing saccades that perfectly obey Listing's law when using a two-dimensional saccadic pulse signal. The model predicted the direction of the axis tilts observed in response to passive head impulses from 50 ms after onset. During passive head impulses, the median optimal pulley coefficient was found to be 0.21, when roll gain was fixed at 0.7. The model did not accurately predict the alignment of the eye and head velocity axes that was observed early in the response to passive head impulses. We found that this alignment could be well predicted if

  14. Eye Protection

    PubMed Central

    Pashby, Tom

    1986-01-01

    Eye injuries frequently occur in the home, at work and at play. Many result in legally blind eyes, and most are preventable. Awareness of potential hazards is essential to preventing eye injuries, particularly in children. In addition, protective devices must be used appropriately. We have developed eye protectors that have proved effective in reducing both the overall incidence and the severity of sports eye injuries. ImagesFigures 2a, bFigure 3Figures 4a, b, c, dFigure 5 PMID:21267100

  15. Defragmented image based autostereoscopic 3D displays with dynamic eye tracking

    NASA Astrophysics Data System (ADS)

    Kim, Sung-Kyu; Yoon, Ki-Hyuk; Yoon, Seon Kyu; Ju, Heongkyu

    2015-12-01

    We studied defragmented image based autostereoscopic 3D displays with dynamic eye tracking. Specifically, we examined the impact of parallax barrier (PB) angular orientation on their image quality. The 3D display system required fine adjustment of PB angular orientation with respect to a display panel. This was critical for both image color balancing and minimizing image resolution mismatch between horizontal and vertical directions. For evaluating uniformity of image brightness, we applied optical ray tracing simulations. The simulations took effects of PB orientation misalignment into account. The simulation results were then compared with recorded experimental data. Our optimal simulated system produced significantly enhanced image uniformity at around sweet spots in viewing zones. However this was contradicted by real experimental results. We offer quantitative treatment of illuminance uniformity of view images to estimate misalignment of PB orientation, which could account for brightness non-uniformity observed experimentally. Our study also shows that slight imperfection in the adjustment of PB orientation due to practical restrictions of adjustment accuracy can induce substantial non-uniformity of view images' brightness. We find that image brightness non-uniformity critically depends on misalignment of PB angular orientation, for example, as slight as ≤ 0.01 ° in our system. This reveals that reducing misalignment of PB angular orientation from the order of 10-2 to 10-3 degrees can greatly improve the brightness uniformity.

  16. Great apes generate goal-based action predictions: an eye-tracking study.

    PubMed

    Kano, Fumihiro; Call, Josep

    2014-09-01

    To examine great apes' on-line prediction of other individuals' actions, we used an eye-tracking technique and an experimental paradigm previously used to test human infants. Twenty-two great apes, including bonobos, chimpanzees, and orangutans, were familiarized to movie clips of a human hand reaching to grasp one of two objects. Then the objects' locations were swapped, and in the test event, the hand made an incomplete reach between the objects. In a control condition, a mechanical claw performed the same actions. The apes predictively looked at the familiarized goal object rather than the familiarized location when viewing the hand action in the test event. However, they made no prediction when viewing the claw action. These results are similar to those reported previously for human infants, and predictive looking did not differ among the three species of great apes. Thus, great apes make on-line goal-based predictions about the actions of other individuals; this skill is not unique to humans but is shared more widely among primates. PMID:25022278

  17. An iris localization algorithm based on geometrical features of cow eyes

    NASA Astrophysics Data System (ADS)

    Zhang, Menglu; Zhao, Lindu; Kong, Qiang

    2009-10-01

    Abrupt vicious affairs on meat food safety show rapid expansion, which poses a threat to food safety and human health. In order to trace the flow of meat products in the food supply chain, the research on the individual identification of large animals based on iris recognition has very important practical significance. Iris localization is the key step in the iris recognition system, and this paper makes the cow iris as an example to propose two-step localization method on the basis of studying and analyzing lots of cow geometrical features. Firstly, threshold transform and Sobel edge detection operator are used to make the image binarization processing and realize coarse location, and the coordinates of boundary points are determined with the quadratic B-spline interpolation curves. Secondly, the cow eye iris image is located from the coarseness to fine through fitting circles. This paper proposes two methods to determine the parameters of the inner and outer boundary circles, including fitting concentric and non-concentric circle. Experimental results show that fitting non-concentric circle algorithm can locate iris region quickly and efficiently and has better accuracy and good robustness.

  18. Eye movements reveal the time-course of anticipating behaviour based on complex, conflicting desires.

    PubMed

    Ferguson, Heather J; Breheny, Richard

    2011-05-01

    The time-course of representing others' perspectives is inconclusive across the currently available models of ToM processing. We report two visual-world studies investigating how knowledge about a character's basic preferences (e.g. Tom's favourite colour is pink) and higher-order desires (his wish to keep this preference secret) compete to influence online expectations about subsequent behaviour. Participants' eye movements around a visual scene were tracked while they listened to auditory narratives. While clear differences in anticipatory visual biases emerged between conditions in Experiment 1, post-hoc analyses testing the strength of the relevant biases suggested a discrepancy in the time-course of predicting appropriate referents within the different contexts. Specifically, predictions to the target emerged very early when there was no conflict between the character's basic preferences and higher-order desires, but appeared to be relatively delayed when comprehenders were provided with conflicting information about that character's desire to keep a secret. However, a second experiment demonstrated that this apparent 'cognitive cost' in inferring behaviour based on higher-order desires was in fact driven by low-level features between the context sentence and visual scene. Taken together, these results suggest that healthy adults are able to make complex higher-order ToM inferences without the need to call on costly cognitive processes. Results are discussed relative to previous accounts of ToM and language processing.

  19. What the human eye tells the brain: a new approach toward a hardware-based modeling of mental functions

    NASA Astrophysics Data System (ADS)

    Lauinger, N.

    2007-09-01

    A better understanding of intelligent information processing in human vision can be reached through a closer look at the macro- and micro-hardware available in the hierarchy of cortical processors along the main visual pathway connecting the retina, the CGL (corpus geniculatum laterale) and area V1 (cortical visual area 17). The building of the eye is driven by the brain and the engineering of the main visual pathway back to V1 seems to be driven by the eyes. The human eye offers to the brain much more intelligent information about the outer visible world than a camera producing flat 2D images on a CCD. Intelligent processing of visual information in human vision - a strong cooperation between eyes and brain - relays on axes related symmetry operations relevant for navigation in 4D spectral space-times, on a hierarchy of dynamically balanced equilibrium states, on diffractive-optical transformation of the Visible into RGB space, on range mapping based on RGB data (monocular and binocular 3D vision), on illuminant-adaptive optical correlations of local onto global RGB data (color constancy performances) and on invariant fourier-optical log-polar processing of image data (generic object classification; identification of objects). These performances are more compatible with optical processing of modern diffractive-optical sensors and interference-optical correlators than with cameras. The R+D project NAMIROS (Nano- and Micro-3D gratings for Optical Sensors) [8], coordinated by an interdisciplinary team of specialists at Corrsys 3D Sensors AG, describes the roadmap towards a technical realization of outstanding high-tech performances corresponding to human eye-brain co-processing.

  20. Modeling of micro cat's eye retroreflectors using a matrix-based three-dimensional ray tracing technique.

    PubMed

    Yang, Bing-jun; Chao, Keng-hsing; Tsai, Jui-che

    2012-09-01

    In this paper we develop a three-dimensional (3D) ray tracing tool based on the ABCD ray transfer matrices. With symmetric optical components and under paraxial approximation, two sets of 2×2 ABCD matrices, each for a two-dimensional subspace, can be used to describe the 3D ray propagation completely. Compared to commercial ray-tracing software packages, our tool requires no tedious drawing, and the results for various conditions, such as different device dimensions and incident angles, can be easily obtained by simply changing the parameter values used for the calculation. We have employed this matrix-based 3D ray tracing tool to model cat's eye retroreflectors. The cat's eye performance, including the retroreflection efficiency, acceptance angle (i.e., field of view), and beam divergence and deviation, is fully studied. The application of this 3D ray tracing technique can be further extended to other optical components.

  1. A Model-Based Approach for the Measurement of Eye Movements Using Image Processing

    NASA Technical Reports Server (NTRS)

    Sung, Kwangjae; Reschke, Millard F.

    1997-01-01

    This paper describes a video eye-tracking algorithm which searches for the best fit of the pupil modeled as a circular disk. The algorithm is robust to common image artifacts such as the droopy eyelids and light reflections while maintaining the measurement resolution available by the centroid algorithm. The presented algorithm is used to derive the pupil size and center coordinates, and can be combined with iris-tracking techniques to measure ocular torsion. A comparison search method of pupil candidates using pixel coordinate reference lookup tables optimizes the processing requirements for a least square fit of the circular disk model. This paper includes quantitative analyses and simulation results for the resolution and the robustness of the algorithm. The algorithm presented in this paper provides a platform for a noninvasive, multidimensional eye measurement system which can be used for clinical and research applications requiring the precise recording of eye movements in three-dimensional space.

  2. Blindness and eye diseases in Tibet: findings from a randomised, population based survey

    PubMed Central

    Dunzhu, S; Wang, F S; Courtright, P; Liu, L; Tenzing, C; Noertjojo, K; Wilkie, A; Santangelo, M; Bassett, K L

    2003-01-01

    Background: Public health officials of the Tibet Autonomous Region (TAR) of China requested a survey of blindness, eye diseases, and eye care service utilisation to assist the development of a 10 year blindness prevention and treatment plan. The objective of the survey was to determine the prevalence of blindness and visual impairment, as well as cataract surgical coverage and surgical outcome in the TAR. Methods: The Tibet Eye Care Assessment was a cross sectional prevalence study of three of the seven prefectures (provinces) of the TAR (Lhoka, Nakchu, and Lingzhr) selected to represent its three main environmental regions. The survey sample was selected using a random multistage cluster method. Two teams conducted the survey in a standardised fashion in each prefecture, Lhoka during May and Nakchu during June 1999, and Lingzhr during May 2000. Visual acuity, cause of vision loss, trachoma, and vitamin A deficiency were included in the clinical examination. Results: Among the 15 900 people enumerated, 12 644 were examined for an overall response rate of 79.6%. The crude prevalence of blindness (presenting better eye visual acuity of less than 6/60) was 2.3%; age and sex adjusted blindness prevalence was 1.4% (95% CI 1.3 to 1.5). Visual impairment (better eye presenting visual acuity of 6/24 to 6/60) was found in 10.9% (95% CI 10.5 to 11.2) of the population (age and sex adjusted). Cataract was the primary cause of blindness (50.7%), followed by macular degeneration (12.7%) and corneal opacity (9.7%). Conclusion: Blindness is a serious public health problem in Tibet, with prevalence higher than in similar studies in eastern China. As elsewhere in the world, women have an excess burden of blindness compared to men. About 75% of blindness in Tibet can be either prevented or treated. Eye care planning for Tibet must focus on cataract, particularly among women. PMID:14660448

  3. Eye development.

    PubMed

    Baker, Nicholas E; Li, Ke; Quiquand, Manon; Ruggiero, Robert; Wang, Lan-Hsin

    2014-06-15

    The eye has been one of the most intensively studied organs in Drosophila. The wealth of knowledge about its development, as well as the reagents that have been developed, and the fact that the eye is dispensable for survival, also make the eye suitable for genetic interaction studies and genetic screens. This article provides a brief overview of the methods developed to image and probe eye development at multiple developmental stages, including live imaging, immunostaining of fixed tissues, in situ hybridizations, and scanning electron microscopy and color photography of adult eyes. Also summarized are genetic approaches that can be performed in the eye, including mosaic analysis and conditional mutation, gene misexpression and knockdown, and forward genetic and modifier screens.

  4. EYE DEVELOPMENT

    PubMed Central

    Baker, Nicholas E.; Li, Ke; Quiquand, Manon; Ruggiero, Robert; Wang, Lan-Hsin

    2014-01-01

    The eye has been one of the most intensively studied organs in Drosophila. The wealth of knowledge about its development, as well as the reagents that have been developed, and the fact that the eye is dispensable for survival, also make the eye suitable for genetic interaction studies and genetic screens. This chapter provides a brief overview of the methods developed to image and probe eye development at multiple developmental stages, including live imaging, immunostaining of fixed tissues, in situ hybridizations, and scanning electron microscopy and color photography of adult eyes. Also summarized are genetic approaches that can be performed in the eye, including mosaic analysis and conditional mutation, gene misexpression and knockdown, and forward genetic and modifier screens. PMID:24784530

  5. Towards Quantum Experiments with Human Eye Detectors Based on Cloning via Stimulated Emission ?

    NASA Astrophysics Data System (ADS)

    De Martini, Francesco

    2010-05-01

    In a recent theoretical paper published in Physical Review Letters, Sekatsky, Brunner, Branciard, Gisin, Simon report an extended investigation on some properties of the human eye that affect its behavior as a quantum detector. We believe that the content of this work, albeit appealing at fist sight, is highly questionable simply because the human eye cannot be adopted as a sensing device within any quantum measurement apparatus. Furthermore, the criticism raised by these Authors against a real experiment on Micro—Macro entanglement recently published in Physical Review Letters (100, 253601, 2008) is found misleading and misses its target.

  6. A wavelet based method for automatic detection of slow eye movements: a pilot study.

    PubMed

    Magosso, Elisa; Provini, Federica; Montagna, Pasquale; Ursino, Mauro

    2006-11-01

    Electro-oculographic (EOG) activity during the wake-sleep transition is characterized by the appearance of slow eye movements (SEM). The present work describes an algorithm for the automatic localisation of SEM events from EOG recordings. The algorithm is based on a wavelet multiresolution analysis of the difference between right and left EOG tracings, and includes three main steps: (i) wavelet decomposition down to 10 detail levels (i.e., 10 scales), using Daubechies order 4 wavelet; (ii) computation of energy in 0.5s time steps at any level of decomposition; (iii) construction of a non-linear discriminant function expressing the relative energy of high-scale details to both high- and low-scale details. The main assumption is that the value of the discriminant function increases above a given threshold during SEM episodes due to energy redistribution toward higher scales. Ten EOG recordings from ten male patients with obstructive sleep apnea syndrome were used. All tracings included a period from pre-sleep wakefulness to stage 2 sleep. Two experts inspected the tracings separately to score SEMs. A reference set of SEM (gold standard) were obtained by joint examination by both experts. Parameters of the discriminant function were assigned on three tracings (design set) to minimize the disagreement between the system classification and classification by the two experts; the algorithm was then tested on the remaining seven tracings (test set). Results show that the agreement between the algorithm and the gold standard was 80.44+/-4.09%, the sensitivity of the algorithm was 67.2+/-7.37% and the selectivity 83.93+/-8.65%. However, most errors were not caused by an inability of the system to detect intervals with SEM activity against NON-SEM intervals, but were due to a different localisation of the beginning and end of some SEM episodes. The proposed method may be a valuable tool for computerized EOG analysis. PMID:16497535

  7. Behavioural and eye-movement outcomes in response to text-based reading treatment for acquired alexia.

    PubMed

    Kim, Esther S; Lemke, Shannon F

    2016-01-01

    Text-based reading treatments, such as Multiple Oral Rereading (MOR) and Oral Reading for Language in Aphasia (ORLA) have been used successfully to remediate reading impairments in individuals with acquired alexia, but the mechanisms underlying such improvements are not well understood. In this study, an individual with acquired alexia who demonstrated reliance on a sub-lexical reading strategy (i.e., presence of spelling regularity effect and phonologically plausible errors) underwent 12 weeks of text-based reading treatment combining MOR and ORLA procedures. Behavioural assessments of single-word and text reading, along with eye-tracking assessments were conducted pre-treatment, post-treatment and at 5 month follow-up. Improved reading fluency (rate, accuracy) was observed for both trained and untrained passages. Evidence from behavioural and eye-tracking assessment suggested text-based reading treatment facilitated use of a lexical-semantic reading strategy. Increased frequency and lexicality effects, as well as a shift in initial landing position towards the centre of the word (the "optimal viewing position") were observed at post-treatment and follow-up assessments. These results demonstrate the potential utility of using eye movements as a parameter of interest in addition to traditional behavioural outcomes when investigating response to reading treatment.

  8. ADAPTIVE EYE MODEL - Poster Paper

    NASA Astrophysics Data System (ADS)

    Galetskiy, Sergey O.; Kudryashov, Alexey V.

    2008-01-01

    We propose experimental adaptive eye model based on flexible 18-electrode bimorph mirror reproducing human eye aberrations up to 4th radial order of Zernike polynomials at frequency of 10Hz. The accuracy of aberrations reproduction in most cases is better than λ/10 RMS. The model is introduced to aberrometer for human eye aberrations compensation to improve visual acuity test.

  9. High-sensitive and high-efficient biochemical analysis method using a bionic electronic eye in combination with a smartphone-based colorimetric reader system.

    PubMed

    Kaiqi Su; Quchao Zou; Ning Hu; Ping Wang

    2015-01-01

    Bionic electronic eye (Bionic e-Eye), a developed smartphone-based colorimetric reader system, consists of smartphone or pad (iPhone 4s or iPad 3) as detection instrument and portable accessory as illumination provider, integrating with a wide-angle lens, a piece of lowest-power electro luminescent and a custom-made dark hood. A 96-well microtiter plate (MTP) was positioned on the electro luminescent and Bionic e-Eye captures the detection images by the back camera of smartphone. Being similar to human visual system, the hue, saturation and value (HSV, also called hex cone model) color model was employed in image processing algorithm of Bionic e-Eye. Optimized system dimension was determined by the system steadiness experiment of different photograph distances. Moreover, the commercially available BCA protein assay and CCK8 cell number assay were carried out to evaluate this Bionic e-Eye. Analytical performance of Bionic e-Eye had the better precision, higher sensitivity than microtiter plate reader (MTPR) and previous smartphone-based colorimetric reader for both two assays. Also, Bionic e-Eye using optical image detection had simultaneous and synchronous working mode, while MPTR using machine moving detection had asynchronous working mode in high throughput detection. Therefore, Bionic e-Eye will be an ideal point-of-care (POC) colorimetric detection device in the field of clinical application, industrial quality control, environment monitoring, and food assessment.

  10. High-sensitive and high-efficient biochemical analysis method using a bionic electronic eye in combination with a smartphone-based colorimetric reader system.

    PubMed

    Kaiqi Su; Quchao Zou; Ning Hu; Ping Wang

    2015-01-01

    Bionic electronic eye (Bionic e-Eye), a developed smartphone-based colorimetric reader system, consists of smartphone or pad (iPhone 4s or iPad 3) as detection instrument and portable accessory as illumination provider, integrating with a wide-angle lens, a piece of lowest-power electro luminescent and a custom-made dark hood. A 96-well microtiter plate (MTP) was positioned on the electro luminescent and Bionic e-Eye captures the detection images by the back camera of smartphone. Being similar to human visual system, the hue, saturation and value (HSV, also called hex cone model) color model was employed in image processing algorithm of Bionic e-Eye. Optimized system dimension was determined by the system steadiness experiment of different photograph distances. Moreover, the commercially available BCA protein assay and CCK8 cell number assay were carried out to evaluate this Bionic e-Eye. Analytical performance of Bionic e-Eye had the better precision, higher sensitivity than microtiter plate reader (MTPR) and previous smartphone-based colorimetric reader for both two assays. Also, Bionic e-Eye using optical image detection had simultaneous and synchronous working mode, while MPTR using machine moving detection had asynchronous working mode in high throughput detection. Therefore, Bionic e-Eye will be an ideal point-of-care (POC) colorimetric detection device in the field of clinical application, industrial quality control, environment monitoring, and food assessment. PMID:26738081

  11. Eye Injuries at Home

    MedlinePlus

    ... Patient Stories Español Eye Health / Tips & Prevention Eye Injuries Sections Preventing Eye Injuries Recognizing and Treating Eye ... Sports Eye Injuries by the Numbers — Infographic Eye Injuries at Home Reviewed by: Brenda Pagan-Duran MD ...

  12. Advanced Clinical Imaging and Tissue-based Biomarkers of the Eye for Toxicology Studies in Minipigs.

    PubMed

    Atzpodien, Elke-Astrid; Jacobsen, Bjoern; Funk, Juergen; Altmann, Bernd; Silva Munoz, Manuel A; Singer, Thomas; Gyger, Cyrill; Hasler, Pascal; Maloca, Peter

    2016-04-01

    There is increased interest to use minipigs in ocular toxicology studies due to their anatomical similarities with human eyes and as a substitute for nonhuman primates. This requires adaptation of enhanced optical coherence tomography (OCT) techniques and of ocular relevant immunohistochemistry (IHC) or in situ hybridization (ISH) markers to porcine eyes. In this study, OCT and OCT angiography (AngioOCT) were performed on adult Göttingen minipigs. To increase structural information on retinal and choroidal vasculature, OCT data were speckle denoized and choroidal blood vessels were segmented with threshold filtering. In addition, we established a set of IHC and ISH markers on Davidson's fixed paraffin-embedded minipig eyes: neurofilament-160, neuronal nuclei, calretinin, protein kinase C-α, vimentin, glial fibrillary acidic protein, glutamine synthetase, ionized calcium-binding adaptor molecule-1, rhodopsin, synaptophysin, postsynaptic density protein-95, retinal pigment epithelium (RPE)-specific protein-65, von Willebrand factor, α-smooth muscle actin, desmin, and Ki-67, thus enabling visualization of retinal neuronal and glial cells, photoreceptors, synapses, RPE, blood vessels, myocytes, macrophages, or cell proliferation. Using ISH, transcripts of vascular endothelial growth factor A, angiopoietin-2, and endothelial tyrosine kinase were visualized. This article describes for the first time in minipig eyes speckle noise-free OCT, AngioOCT, and a set of IHC/ISH markers on Davidson's fixed paraffin-embedded tissues and helps to establish the minipig for ocular toxicology and pharmacology studies. PMID:26680760

  13. Similarity-Based Interference during Language Comprehension: Evidence from Eye Tracking during Reading

    ERIC Educational Resources Information Center

    Gordon, Peter C.; Hendrick, Randall; Johnson, Marcus; Lee, Yoonhyoung

    2006-01-01

    The nature of working memory operation during complex sentence comprehension was studied by means of eye-tracking methodology. Readers had difficulty when the syntax of a sentence required them to hold 2 similar noun phrases (NPs) in working memory before syntactically and semantically integrating either of the NPs with a verb. In sentence …

  14. A novel attention training paradigm based on operant conditioning of eye gaze: Preliminary findings.

    PubMed

    Price, Rebecca B; Greven, Inez M; Siegle, Greg J; Koster, Ernst H W; De Raedt, Rudi

    2016-02-01

    Inability to engage with positive stimuli is a widespread problem associated with negative mood states across many conditions, from low self-esteem to anhedonic depression. Though attention retraining procedures have shown promise as interventions in some clinical populations, novel procedures may be necessary to reliably attenuate chronic negative mood in refractory clinical populations (e.g., clinical depression) through, for example, more active, adaptive learning processes. In addition, a focus on individual difference variables predicting intervention outcome may improve the ability to provide such targeted interventions efficiently. To provide preliminary proof-of-principle, we tested a novel paradigm using operant conditioning to train eye gaze patterns toward happy faces. Thirty-two healthy undergraduates were randomized to receive operant conditioning of eye gaze toward happy faces (train-happy) or neutral faces (train-neutral). At the group level, the train-happy condition attenuated sad mood increases following a stressful task, in comparison to train-neutral. In individual differences analysis, greater physiological reactivity (pupil dilation) in response to happy faces (during an emotional face-search task at baseline) predicted decreased mood reactivity after stress. These Preliminary results suggest that operant conditioning of eye gaze toward happy faces buffers against stress-induced effects on mood, particularly in individuals who show sufficient baseline neural engagement with happy faces. Eye gaze patterns to emotional face arrays may have a causal relationship with mood reactivity. Personalized medicine research in depression may benefit from novel cognitive training paradigms that shape eye gaze patterns through feedback. Baseline neural function (pupil dilation) may be a key mechanism, aiding in iterative refinement of this approach.

  15. A novel attention training paradigm based on operant conditioning of eye gaze: Preliminary findings.

    PubMed

    Price, Rebecca B; Greven, Inez M; Siegle, Greg J; Koster, Ernst H W; De Raedt, Rudi

    2016-02-01

    Inability to engage with positive stimuli is a widespread problem associated with negative mood states across many conditions, from low self-esteem to anhedonic depression. Though attention retraining procedures have shown promise as interventions in some clinical populations, novel procedures may be necessary to reliably attenuate chronic negative mood in refractory clinical populations (e.g., clinical depression) through, for example, more active, adaptive learning processes. In addition, a focus on individual difference variables predicting intervention outcome may improve the ability to provide such targeted interventions efficiently. To provide preliminary proof-of-principle, we tested a novel paradigm using operant conditioning to train eye gaze patterns toward happy faces. Thirty-two healthy undergraduates were randomized to receive operant conditioning of eye gaze toward happy faces (train-happy) or neutral faces (train-neutral). At the group level, the train-happy condition attenuated sad mood increases following a stressful task, in comparison to train-neutral. In individual differences analysis, greater physiological reactivity (pupil dilation) in response to happy faces (during an emotional face-search task at baseline) predicted decreased mood reactivity after stress. These Preliminary results suggest that operant conditioning of eye gaze toward happy faces buffers against stress-induced effects on mood, particularly in individuals who show sufficient baseline neural engagement with happy faces. Eye gaze patterns to emotional face arrays may have a causal relationship with mood reactivity. Personalized medicine research in depression may benefit from novel cognitive training paradigms that shape eye gaze patterns through feedback. Baseline neural function (pupil dilation) may be a key mechanism, aiding in iterative refinement of this approach. PMID:26389646

  16. Liquid Crystal based adaptive optics system to compensate both low and high order aberrations in a model eye

    NASA Astrophysics Data System (ADS)

    Mu, Quanquan; Cao, Zhaoliang; Li, Dayu; Hu, Lifa; Xuan, Li

    2007-02-01

    Based on a simple eye model system, a high resolution adaptive optics retina imaging system was built to demonstrate the availability of using liquid crystal devices as a wave-front corrector for both low and high order aberrations. Myopia glass was used to introduce large low order aberrations. A fiber bundle was used to simulate the retina. After correction, its image at different diopters became very clear. We can get a root mean square (RMS) correction precision of lower than 0.049λ (λ=0.63μm) for over to 10 diopters and the modulation transfer function (MTF) retains 511p/mm, which is nearly the diffraction limited resolution for a 2.7mm pupil diameter. The closed loop bandwidth was nearly 4 Hz, which is capable to track most of the aberration dynamics in a real eye.

  17. Eye Complications

    MedlinePlus

    ... the cornea, which focuses light while protecting the eye. After light passes through the cornea, it travels through a ... and have them progress faster. With cataracts, the eye's clear lens clouds, blocking light. To help deal with mild cataracts, you may ...

  18. A naked-eye sensing ensemble for the selective detection of citrate--but not tartrate or malate--in water based on a tris-cationic receptor.

    PubMed

    Schmuck, Carsten; Schwegmann, Michael

    2006-03-01

    Citrate 3 can be selectively detected in aqueous solvents even in the presence of malate or tartrate using a naked-eye detection system based on the complex between tris-cation 1 and carboxyfluorescein 2.

  19. Fiber-based polarization-sensitive OCT for birefringence imaging of the anterior eye segment.

    PubMed

    Yamanari, Masahiro; Tsuda, Satoru; Kokubun, Taiki; Shiga, Yukihiro; Omodaka, Kazuko; Yokoyama, Yu; Himori, Noriko; Ryu, Morin; Kunimatsu-Sanuki, Shiho; Takahashi, Hidetoshi; Maruyama, Kazuichi; Kunikata, Hiroshi; Nakazawa, Toru

    2015-02-01

    We demonstrate a prototype system of polarization-sensitive optical coherence tomography (PS-OCT) designed for clinical studies of the anterior eye segment imaging. The system can measure Jones matrices of the sample with depth-multiplexing of two orthogonal incident polarizations and polarization-sensitive detection. An optical clock is generated using a quadrature modulator and a logical circuit to double the clock frequency. Systematic artifacts in measured Jones matrices are theoretically analyzed and numerically compensated using signals at the surface of the sample. Local retardation images of filtering blebs after trabeculectomy show improved visualization of subconjunctival tissue, sclera, and scar tissue of the bleb wall in the anterior eye segment. PMID:25780730

  20. Eye fixation during multiple object attention is based on a representation of discrete spatial foci

    PubMed Central

    Fluharty, Meg; Jentzsch, Ines; Spitschan, Manuel; Vishwanath, Dhanraj

    2016-01-01

    We often look at and attend to several objects at once. How the brain determines where to point our eyes when we do this is poorly understood. Here we devised a novel paradigm to discriminate between different models of spatial selection guiding fixation. In contrast to standard static attentional tasks where the eye remains fixed at a predefined location, observers selected their own preferred fixation position while they tracked static targets that were arranged in specific geometric configurations and which changed identity over time. Fixations were best predicted by a representation of discrete spatial foci, not a polygonal grouping, simple 2-foci division of attention or a circular spotlight. Moreover, attentional performance was incompatible with serial selection. Together with previous studies, our findings are compatible with a view that attentional selection and fixation rely on shared spatial representations and suggest a more nuanced definition of overt vs. covert attention. PMID:27561413

  1. Healthy Eyes in Schools: An Evaluation of a School and Community-Based Intervention to Promote Eye Health in Rural Timor-Leste

    ERIC Educational Resources Information Center

    Hobday, Karen; Ramke, Jacqueline; du Toit, Rènée; Pereira, Sara M.

    2015-01-01

    Objective: To assess whether there was an improvement in the knowledge, attitudes and practices of students after the Healthy Eyes in Schools Project intervention and to complete a process evaluation to inform future implementation of health promotion interventions. Design: A descriptive, mixed-methods design was used, including questionnaires and…

  2. An acoustic Maxwell’s fish-eye lens based on gradient-index metamaterials

    NASA Astrophysics Data System (ADS)

    Yuan, Bao-guo; Tian, Ye; Cheng, Ying; Liu, Xiao-jun

    2016-10-01

    We have proposed a two-dimensional acoustic Maxwell’s fish-eye lens by using the gradient-index metamaterials with space-coiling units. By adjusting the structural parameters of the units, the refractive index can be gradually varied, which is key role to design the acoustic fish-eye lens. As predicted by ray trajectories on a virtual sphere, the proposed lens has the capability to focus the acoustic wave irradiated from a point source at the surface of the lens on the diametrically opposite side of the lens. The broadband and low loss performance is further demonstrated for the lens. The proposed acoustic fish-eye lens is expected to have the potential applications in directional acoustic coupler or coherent ultrasonic imaging. Project supported by the National Basic Research Program of China (Grant No. 2012CB921504), the National Natural Science Foundation of China (Grant Nos. 11574148, 11474162, 1274171, 11674172, and 11674175), and the Specialized Research Fund for the Doctoral Program of Higher Education, China (Grant Nos. 20110091120040 and 20120091110001).

  3. Development of a hybrid mental speller combining EEG-based brain-computer interface and webcam-based eye-tracking.

    PubMed

    Lee, Jun-Hak; Lim, Jeong-Hwan; Hwang, Han-Jeong; Im, Chang-Hwan

    2013-01-01

    The main goal of this study was to develop a hybrid mental spelling system combining a steady-state visual evoked potential (SSVEP)-based brain-computer interface (BCI) technology and a webcam-based eye-tracker, which utilizes information from the brain electrical activity and eye gaze direction at the same time. In the hybrid mental spelling system, a character decoded using SSVEP was not typed if the position of the selected character was not matched with the eye direction information ('left' or 'right') obtained from the eye-tracker. Thus, the users did not need to correct a misspelled character using a 'BACKSPACE' key. To verify the feasibility of the developed hybrid mental spelling system, we conducted online experiments with ten healthy participants. Each participant was asked to type 15 English words consisting of 68 characters. As a result, 16.6 typing errors could be prevented on average, demonstrating that the implemented hybrid mental spelling system could enhance the practicality of our mental spelling system. PMID:24110169

  4. Eyes - bulging

    MedlinePlus

    ... getting worse? What other symptoms do you have? A slit-lamp examination may be done. Blood testing for thyroid disease may be done. Treatments depend on the cause. Artificial tears may be given to lubricate the eye.

  5. Eye Infections

    MedlinePlus

    ... Health Issues Conditions Abdominal ADHD Allergies & Asthma Autism Cancer Chest & Lungs Chronic Conditions Cleft & Craniofacial Developmental Disabilities Ear Nose & Throat Emotional Problems Eyes Fever From Insects or Animals Genitals and Urinary Tract Glands & Growth ...

  6. Eye emergencies

    MedlinePlus

    Supervise children carefully. Teach them how to be safe. Always wear protective eye gear when: Using power tools, hammers, or other striking tools Working with toxic chemicals Cycling or when in windy and dusty ...

  7. Eye Allergies

    MedlinePlus

    ... MD Mar. 01, 2015 Eye allergies, called allergic conjunctivitis , are a common condition that occurs when the ... with tearing and burning. Unlike bacterial or viral conjunctivitis, allergic conjunctivitis is not spread from person to ...

  8. Black Eye

    MedlinePlus

    ... Aug 30, 2016 Toddlers Most at Risk of Chemical Burns to Eyes Aug 26, 2016 Firework Blinds Teenager, Severs Hand Jun 29, ... at the Academy Financial Relationships with Industry Medical Disclaimer Privacy Policy Terms of Service For ...

  9. Towards Quantum Experiments with Human Eyes as Detectors Based on Cloning via Stimulated Emission

    NASA Astrophysics Data System (ADS)

    Sekatski, Pavel; Brunner, Nicolas; Branciard, Cyril; Gisin, Nicolas; Simon, Christoph

    2009-09-01

    We show theoretically that a large Bell inequality violation can be obtained with human eyes as detectors, in a “micro-macro” experiment where one photon from an entangled pair is greatly amplified via stimulated emission. The violation is robust under photon loss. This leads to an apparent paradox, which we resolve by noting that the violation proves the existence of entanglement before the amplification. The same is true for the micro-macro experiments performed so far with conventional detectors. However, we also prove that there is genuine micro-macro entanglement even for high loss.

  10. Detection of alpha electro-encephalogram onset following eye closure using four location-based techniques.

    PubMed

    Searle, A; Kirkup, L

    2001-07-01

    Detection of alpha activity in the electro-encephalogram (EEG) has been used extensively in neurophysiological studies. Previously applied alpha parameterisation techniques, which utilise the amplitude information from a pair of differential electrodes, are often susceptible to interference from artifact signals. This is an issue if the purpose of detecting the change in alpha wave synchronisation is the basis of an environmental control system (ECS). An alternative approach to alpha activity detection is proposed that utilises the information from an array of electrodes on the scalp to estimate the apparent location of alpha activity in the brain. Four methods are described that successfully detect the onset of alpha EEG increase following eye closure by monitoring the apparent location of alpha activity in the head. The methods use Bartlett beamforming, a four-sphere anatomical head model, the MUSIC algorithm and a new 'power vector' technique. Of the methods described, the power vector technique is found to be the most successful. The power vector technique detects the alpha increase associated with eye closure in times that are, on average, 33% lower than previously applied alpha detection methods. PMID:11523732

  11. Ion therapy for uveal melanoma in new human eye phantom based on GEANT4 toolkit.

    PubMed

    Mahdipour, Seyed Ali; Mowlavi, Ali Asghar

    2016-01-01

    Radiotherapy with ion beams like proton and carbon has been used for treatment of eye uveal melanoma for many years. In this research, we have developed a new phantom of human eye for Monte Carlo simulation of tumors treatment to use in GEANT4 toolkit. Total depth-dose profiles for the proton, alpha, and carbon incident beams with the same ranges have been calculated in the phantom. Moreover, the deposited energy of the secondary particles for each of the primary beams is calculated. The dose curves are compared for 47.8MeV proton, 190.1MeV alpha, and 1060MeV carbon ions that have the same range in the target region reaching to the center of tumor. The passively scattered spread-out Bragg peak (SOBP) for each incident beam as well as the flux curves of the secondary particles including neutron, gamma, and positron has been calculated and compared for the primary beams. The high sharpness of carbon beam׳s Bragg peak with low lateral broadening is the benefit of this beam in hadrontherapy but it has disadvantages of dose leakage in the tail after its Bragg peak and high intensity of neutron production. However, proton beam, which has a good conformation with tumor shape owing to the beam broadening caused by scattering, can be a good choice for the large-size tumors. PMID:26831752

  12. Linear fitting interpolation based on FOV division for correcting wide angle fish-eye lens distortion

    NASA Astrophysics Data System (ADS)

    Li, An; Wu, Yi-si; Chen, Chi; Zheng, Zhen-rong

    2015-09-01

    The wide angle lens, like fish eye lens, suffers great optical distortion that causes severe deformation of the real world. A method to correct the strong distortion was presented in this work. Due to the nonlinear distribution of the distortion, linear algorithms are generally not under consideration to establish the math model of distorted-to-ideal images. However, this method employed the calibration pattern that comprised of regular array of dots to divides the full field of view (FOV) to subsections, each subsection is a small FOV, the mapping parameters between the distorted image and ideal image in each small FOV can be calculated by employing the very simple linear polynomial. Thus, applying the determined parameters to their corresponding sub-FOVs, respectively, all the ideal pixel coordinates of the distorted image can be obtained. The method employed linear polynomial characterizes the geometric deformation between the distorted and ideal images directly. Therefore, it contains both of radial distortion and tangential distortion and there is no need of concerning any intrinsic or extrinsic parameters of the optical systems. So, this algorithm reliefs the computational work that employed by conventional radial models and other mathematical models. Experiments performed on off-axis optical systems which exist complicated distortion, such as the head mounted displays (HMDs), had already yielded accurate correcting results. Likewise, in this paper, the experiments refer to the fish-eye lens also verify the effectiveness and flexibility of this method, as well, high correcting accuracy is achieved.

  13. Eye region-based fusion technique of thermal and dark visual images for human face recognition

    NASA Astrophysics Data System (ADS)

    Bhowmik, Mrinal Kanti; Bhattacharjee, Debotosh; Basu, Dipak Kumar; Nasipuri, Mita

    2012-07-01

    We present an approach for human face recognition using eye region extraction/replacement method under low illumination and varying expression conditions. For conducting experiments, two different sets of face images, namely visual and corresponding thermal, are used from Imaging, Robotics, and Intelligent Systems (IRIS) thermal/visual face data. A decomposition and reconstruction technique of Daubechies wavelet co-efficient (db4) is used to generate the fused image by replacing the eye region in the visual image with the same region from the corresponding thermal image. After that, independent component analysis over the natural logarithm domain (Log-ICA) is used for feature extraction/dimensionality reduction, and finally, a classifier is used to classify the fused face images. Two different image sets, i.e., training and test image sets, are mainly prepared using the IRIS thermal/visual face database for finding the accuracy of the proposed system. Experimental results show the proposed method is more efficient than other image fusion techniques which have used region extraction techniques for dark faces.

  14. Multimodal eye recognition

    NASA Astrophysics Data System (ADS)

    Zhou, Zhi; Du, Yingzi; Thomas, N. L.; Delp, Edward J., III

    2010-04-01

    Multimodal biometrics use more than one means of biometric identification to achieve higher recognition accuracy, since sometimes a unimodal biometric is not good enough used to do identification and classification. In this paper, we proposed a multimodal eye recognition system, which can obtain both iris and sclera patterns from one color eye image. Gabor filter and 1-D Log-Gabor filter algorithms have been applied as the iris recognition algorithms. In sclera recognition, we introduced automatic sclera segmentation, sclera pattern enhancement, sclera pattern template generation, and sclera pattern matching. We applied kernelbased matching score fusion to improve the performance of the eye recognition system. The experimental results show that the proposed eye recognition method can achieve better performance compared to unimodal biometric identification, and the accuracy of our proposed kernel-based matching score fusion method is higher than two classic linear matching score fusion methods: Principal Component Analysis (PCA) and Linear Discriminant Analysis (LDA).

  15. Are higher blood mercury levels associated with dry eye symptoms in adult Koreans? A population-based cross-sectional study

    PubMed Central

    Chung, So-Hyang

    2016-01-01

    Objectives The purpose of this study was to investigate whether blood mercury concentrations associated with the presence of dry eye symptoms in a nationally representative Korean population. Methods Population-based prospective cross-sectional study using the heavy metal data set of the 2010–2012 Korean National Health and Nutrition Examination Survey (KNHANES). A total of 4761 adult Koreans were the eligible population in this study. Of the 7162 survey participants, 2401 were excluded because they were <19 years of age, there were missing data in the heavy metal data set, or they had diabetes, rheumatoid arthritis, thyroid disease, asthma, depression and/or under-the-eye surgery. Blood mercury levels were measured on the day the participants completed a questionnaire regarding the presence of dry eye symptoms (persistent dryness or eye irritation). The population was divided into low and high groups by median level (4.26 and 2.89 µg/L for males and females, respectively). Results Self-reported dry eye symptoms were present in 13.0% of the cohort. Participants with dry eye symptoms were significantly more likely to have blood mercury levels exceeding the median than those without dry eye symptoms (45.7% vs 51.7%, p=0.021). Logistic regression analysis showed that, after adjusting for age, gender, education, total household income, smoking status, heavy alcohol use, sleep time, perceived stress status, total cholesterol levels and atopy history, dry eye symptoms were significantly associated with blood mercury levels that exceeded the median (reference: lower mercury group; OR, 1.324; 95% CI 1.059 to 1.655; p<0.05). Conclusions High blood mercury levels were associated with dry eye symptoms in a nationally representative Korean population. PMID:27121705

  16. Improving video captioning for deaf and hearing-impaired people based on eye movement and attention overload

    NASA Astrophysics Data System (ADS)

    Chapdelaine, C.; Gouaillier, V.; Beaulieu, M.; Gagnon, L.

    2007-02-01

    Deaf and hearing-impaired people capture information in video through visual content and captions. Those activities require different visual attention strategies and up to now, little is known on how caption readers balance these two visual attention demands. Understanding these strategies could suggest more efficient ways of producing captions. Eye tracking and attention overload detections are used to study these strategies. Eye tracking is monitored using a pupilcenter- corneal-reflection apparatus. Afterward, gaze fixation is analyzed for each region of interest such as caption area, high motion areas and faces location. This data is also used to identify the scanpaths. The collected data is used to establish specifications for caption adaptation approach based on the location of visual action and presence of character faces. This approach is implemented in a computer-assisted captioning software which uses a face detector and a motion detection algorithm based on the Lukas-Kanade optical flow algorithm. The different scanpaths obtained among the subjects provide us with alternatives for conflicting caption positioning. This implementation is now undergoing a user evaluation with hearing impaired participants to validate the efficiency of our approach.

  17. About the effect of eye blinking on drug release from pHEMA-based hydrogels: an in vitro study.

    PubMed

    Galante, R; Paradiso, P; Moutinho, M G; Fernandes, A I; Mata, J L G; Matos, A P A; Colaço, R; Saramago, B; Serro, A P

    2015-01-01

    The development of new ophthalmic drug delivery systems capable of increasing the residence time of drugs in the eye and improve its bioavailability relatively to eyedrops has been object of intense research in recent years. Several studies have shown that drug-loaded therapeutic soft contact lenses (SCLs) constitute a promising approach, with several potential advantages as compared with collyria. The main objective of this work is to study the effect of repetitive load and friction cycles caused by the eye blinking, on the drug release from hydrogels used in SCLs which, as far as we know, was never investigated before. Two poly-2-hydroxyethylmethacrylate-based hydrogels, pHEMA-T and pHEMA-UV, were used as model materials. Levofloxaxin was chosen as model drug. The hydrogels were fully characterized in what concerns structural and physicochemical properties. pHEMA-UV revealed some superficial porosity and a lower short-range order than pHEMA-T. We observe that the load and friction cycles enhanced the drug release from pHEMA-UV hydrogels. The application of a simple mathematical model, which takes into account the drug dilution caused by the tear flow, showed that the enhancement of the drug release caused by blinking on this hydrogel may be relevant in in vivo conditions. Conversely, the more sustained drug release from pHEMA-T is not affected by load and friction cycles. The conclusion is that, depending on the physicochemical and microstructural characteristics of the hydrogels, blinking is a factor that may affect the amount of drug delivered to the eye by SCLs and should thus be considered.

  18. Limbus- versus fornix-based trabeculectomy for open-angle glaucoma eyes with prior ocular surgery: the Collaborative Bleb-Related Infection Incidence and Treatment Study.

    PubMed

    Yokota, Satoshi; Takihara, Yuji; Inatani, Masaru

    2015-03-19

    We compared the surgical successes of limbus- and fornix-based trabeculectomies in open-angle glaucoma (OAG) eyes that had prior ocular surgery in the Collaborative Bleb-Related Infection Incidence and Treatment Study (CBIITS), Japan. From the 1,098 glaucoma eyes in 34 clinical centers in CBIITS, 195 OAG eyes that had undergone previous trabeculectomy and/or lens extraction were included. Limbus- or fornix-based trabeculectomy with mitomycin C were performed. Surgical failure (IOP ≥ 21, 18, or 15 mmHg for criterion A, B or C, respectively; <20% decrease from baseline; reoperation for glaucoma; or loss of light perception vision) was counted. There were 106 and 89 eyes treated with limbus- and fornix-based trabeculectomies, respectively. At 3 years, IOP (mean ± SD) was 12.5 ± 5.9 and 14.1 ± 6.4 mmHg and the cumulative probabilities of failure during 3 years were 30.2% and 50.5% for criterion A, 40.3% and 57.4% for criterion B, and 57.9% and 65.8% for criterion C in the limbus- and the fornix-based group, respectively. Fornix-based incisions were associated with surgical failure in Cox-proportional multivariable analysis for criterion A [relative risk (RR) = 1.96], and B [RR = 1.60]. Limbus-based trabeculectomy had a higher probability of success in OAG eyes with prior ocular surgery.

  19. Screening neonatal jaundice based on the sclera color of the eye using digital photography

    PubMed Central

    Leung, Terence S.; Kapur, Karan; Guilliam, Ashley; Okell, Jade; Lim, Bee; MacDonald, Lindsay W.; Meek, Judith

    2015-01-01

    A new screening technique for neonatal jaundice is proposed exploiting the yellow discoloration in the sclera. It involves taking digital photographs of newborn infants’ eyes (n = 110) and processing the pixel colour values of the sclera to predict the total serum bilirubin (TSB) levels. This technique has linear and rank correlation coefficients of 0.75 and 0.72 (both p<0.01) with the measured TSB. The mean difference ( ± SD) is 0.00 ± 41.60 µmol/l. The receiver operating characteristic curve shows that this technique can identify subjects with TSB above 205 µmol/l with sensitivity of 1.00 and specificity of 0.50, showing its potential as a screening device. PMID:26601015

  20. Screening neonatal jaundice based on the sclera color of the eye using digital photography.

    PubMed

    Leung, Terence S; Kapur, Karan; Guilliam, Ashley; Okell, Jade; Lim, Bee; MacDonald, Lindsay W; Meek, Judith

    2015-11-01

    A new screening technique for neonatal jaundice is proposed exploiting the yellow discoloration in the sclera. It involves taking digital photographs of newborn infants' eyes (n = 110) and processing the pixel colour values of the sclera to predict the total serum bilirubin (TSB) levels. This technique has linear and rank correlation coefficients of 0.75 and 0.72 (both p<0.01) with the measured TSB. The mean difference ( ± SD) is 0.00 ± 41.60 µmol/l. The receiver operating characteristic curve shows that this technique can identify subjects with TSB above 205 µmol/l with sensitivity of 1.00 and specificity of 0.50, showing its potential as a screening device. PMID:26601015

  1. Eye and orbit ultrasound

    MedlinePlus

    Echography - eye orbit; Ultrasound - eye orbit; Ocular ultrasonography; Orbital ultrasonography ... eye is numbed with medicine (anesthetic drops). The ultrasound wand (transducer) is placed against the front surface ...

  2. Googly Eyes

    ERIC Educational Resources Information Center

    Boss, Susan

    2009-01-01

    Beverage take-out trays are funky in their form and function. In this article, the author describes how to make googly eye masks out of discarded take-out trays and other common recycled or discarded materials. (Contains 1 online resource.)

  3. Mindless reading revisited: an analysis based on the SWIFT model of eye-movement control.

    PubMed

    Nuthmann, Antje; Engbert, Ralf

    2009-02-01

    In this article, we revisit the mindless reading paradigm from the perspective of computational modeling. In the standard version of the paradigm, participants read sentences in both their normal version as well as the transformed (or mindless) version where each letter is replaced with a z. z-String scanning shares the oculomotor requirements with reading but none of the higher-level lexical and semantic processes. Here we use the z-string scanning task to validate the SWIFT model of saccade generation [Engbert, R., Nuthmann, A., Richter, E., & Kliegl, R. (2005). SWIFT: A dynamical model of saccade generation during reading. Psychological Review, 112(4), 777-813] as an example for an advanced theory of eye-movement control in reading. We test the central assumption of spatially distributed processing across an attentional gradient proposed by the SWIFT model. Key experimental results like prolonged average fixation durations in z-string scanning compared to normal reading and the existence of a string-length effect on fixation durations and probabilities were reproduced by the model, which lends support to the model's assumptions on visual processing. Moreover, simulation results for patterns of regressive saccades in z-string scanning confirm SWIFT's concept of activation field dynamics for the selection of saccade targets.

  4. Optical performance simulation of free-form optics for an eye implant based on a measurement data enhanced model.

    PubMed

    Sieber, Ingo; Li, Likai; Gengenbach, Ulrich; Beckert, Erik; Steinkopf, Ralf; Yi, Allen Y

    2016-08-20

    This paper describes the application of a modeling approach for precise optical performance prediction of free-form optics-based subsystems on a demonstration model of an eye implant. The simulation model is enhanced by surface data measured on the free-form lens parts. The manufacturing of the free-form lens parts is realized by two different manufacturing processes: ultraprecision diamond machining and microinjection molding. Evaluation of both processes is conducted by a simulation of the optical performance on the basis of their surface measurement comparisons with the nominal geometry. The simulation results indicate that improvements from the process optimization of microinjection molding were obtained for the best manufacturing accuracy. PMID:27556988

  5. Fabrication and characterization of nitride-based blue light-emitting diodes on moth-eye patterned sapphire substrate (MPSS)

    NASA Astrophysics Data System (ADS)

    Tsuchiya, T.; Umeda, S.; Sowa, Mihoko; Kondo, T.; Kitano, T.; Mori, M.; Suzuki, A.; Naniwae, K.; Sekine, H.; Iwaya, M.; Takeuchi, T.; Kamiyama, S.; Akasaki, I.

    2013-03-01

    The fabrication procedure of a moth-eye patterned sapphire substrate (MPSS), which can enhance the light extraction efficiency of nitride-based light emitting diodes (LEDs) has been examined. The optimization of surface morphology after the etching of the MPSS for high-quality GaN growth was also performed. Then, we fabricated MPSS samples with a fixed pitch of 460nm, and corn height ranging from 50 to 350nm. The light extraction efficiency of blue-LEDs grown on a series of MPSS was enhanced about 1.4 times compared with the devices grown on a flat sapphire substrate. We found that if corn height exceeds 150nm, the MPSS effect is sufficiently observed.

  6. Eye Movement Disorders

    MedlinePlus

    ... t work properly. There are many kinds of eye movement disorders. Two common ones are Strabismus - a disorder ... of the eyes, sometimes called "dancing eyes" Some eye movement disorders are present at birth. Others develop over ...

  7. Dilating Eye Drops

    MedlinePlus

    ... Conditions Most Common Searches Adult Strabismus Amblyopia Cataract Conjunctivitis Corneal Abrasions Dilating Eye Drops Lazy eye (defined) ... Loading... Most Common Searches Adult Strabismus Amblyopia Cataract Conjunctivitis Corneal Abrasions Dilating Eye Drops Lazy eye (defined) ...

  8. Why Do Eyes Water?

    MedlinePlus

    ... Help White House Lunch Recipes Why Do Eyes Water? KidsHealth > For Kids > Why Do Eyes Water? Print ... out of your nose. continue Why Do Eyes Water? Eyes water for lots of different reasons besides ...

  9. Eye contricks

    PubMed Central

    Wade, Nicholas J

    2011-01-01

    Pictorial images are icons as well as eye-cons: they provide distillations of objects or ideas into simpler shapes. They create the impression of representing that which cannot be presented. Even at the level of the photograph, the links between icon and object are tenuous. The dimensions of depth and motion are missing from icons, and these alone introduce all manner of potential ambiguities. The history of art can be considered as exploring the missing link between icon and object. Eye-cons can also be illusions—tricks of vision so that what is seen does not necessarily correspond to what is physically presented. Pictorial images can be spatialised or stylised; spatialised images generally share some of the projective characteristics of the object represented. Written words are also icons, but they do not resemble the objects they represent—they are stylised or conventional. Icons as stylised words and spatialised images were set in delightful opposition by René Magritte in a series of pipe paintings, and this theme is here alluded to. Most of visual science is now concerned with icons—two-dimensional displays on computer monitors. Is vision now the science of eye-cons? PMID:23145240

  10. TH-E-17A-10: Markerless Lung Tumor Tracking Based On Beams Eye View EPID Images

    SciTech Connect

    Chiu, T; Kearney, V; Liu, H; Jiang, L; Foster, R; Mao, W; Rozario, T; Bereg, S; Klash, S

    2014-06-15

    Purpose: Dynamic tumor tracking or motion compensation techniques have proposed to modify beam delivery following lung tumor motion on the flight. Conventional treatment plan QA could be performed in advance since every delivery may be different. Markerless lung tumor tracking using beams eye view EPID images provides a best treatment evaluation mechanism. The purpose of this study is to improve the accuracy of the online markerless lung tumor motion tracking method. Methods: The lung tumor could be located on every frame of MV images during radiation therapy treatment by comparing with corresponding digitally reconstructed radiograph (DRR). A kV-MV CT corresponding curve is applied on planning kV CT to generate MV CT images for patients in order to enhance the similarity between DRRs and MV treatment images. This kV-MV CT corresponding curve was obtained by scanning a same CT electron density phantom by a kV CT scanner and MV scanner (Tomotherapy) or MV CBCT. Two sets of MV DRRs were then generated for tumor and anatomy without tumor as the references to tracking the tumor on beams eye view EPID images. Results: Phantom studies were performed on a Varian TrueBeam linac. MV treatment images were acquired continuously during each treatment beam delivery at 12 gantry angles by iTools. Markerless tumor tracking was applied with DRRs generated from simulated MVCT. Tumors were tracked on every frame of images and compared with expected positions based on programed phantom motion. It was found that the average tracking error were 2.3 mm. Conclusion: This algorithm is capable of detecting lung tumors at complicated environment without implanting markers. It should be noted that the CT data has a slice thickness of 3 mm. This shows the statistical accuracy is better than the spatial accuracy. This project has been supported by a Varian Research Grant.

  11. Building metamemorial knowledge over time: insights from eye tracking about the bases of feeling-of-knowing and confidence judgments

    PubMed Central

    Chua, Elizabeth F.; Solinger, Lisa A.

    2015-01-01

    Metamemory processes depend on different factors across the learning and memory time-scale. In the laboratory, subjects are often asked to make prospective feeling-of-knowing (FOK) judgments about target retrievability, or are asked to make retrospective confidence judgments (RCJs) about the retrieved target. We examined distinct and shared contributors to metamemory judgments, and how they were built over time. Eye movements were monitored during a face-scene associative memory task. At test, participants viewed a studied scene, then rated their FOK that they would remember the associated face. This was followed by a forced choice recognition test and RCJs. FOK judgments were less accurate than RCJ judgments, showing that the addition of mnemonic experience can increase metacognitive accuracy over time. However, there was also evidence that the given FOK rating influenced RCJs. Turning to eye movements, initial analyses showed that higher cue fluency was related to both higher FOKs and higher RCJs. However, further analyses revealed that the effects of the scene cue on RCJs were mediated by FOKs. Turning to the target, increased viewing time and faster viewing of the correct associate related to higher FOKs, consistent with the idea that target accessibility is a basis of FOKs. In contrast, the amount of viewing directed to the chosen face, regardless of whether it was correct, predicted higher RCJs, suggesting that choice experience is a significant contributor RCJs. We also examined covariates of the change in RCJ rating from the FOK rating, and showed that increased and faster viewing of the chosen face predicted raising one’s confidence above one’s FOK. Taken together these results suggest that metamemory judgments should not be thought of only as distinct subjective experiences, but complex processes that interact and evolve as new psychological bases for subjective experience become available. PMID:26347677

  12. Video-Based Eye Tracking to Detect the Attention Shift: A Computer Classroom Context-Aware System

    ERIC Educational Resources Information Center

    Kuo, Yung-Lung; Lee, Jiann-Shu; Hsieh, Min-Chai

    2014-01-01

    Eye and head movements evoked in response to obvious visual attention shifts. However, there has been little progress on the causes of absent-mindedness so far. The paper proposes an attention awareness system that captures the conditions regarding the interaction of eye gaze and head pose under various attentional switching in computer classroom.…

  13. Classification of binary intentions for individuals with impaired oculomotor function: ‘eyes-closed’ SSVEP-based brain-computer interface (BCI)

    NASA Astrophysics Data System (ADS)

    Lim, Jeong-Hwan; Hwang, Han-Jeong; Han, Chang-Hee; Jung, Ki-Young; Im, Chang-Hwan

    2013-04-01

    Objective. Some patients suffering from severe neuromuscular diseases have difficulty controlling not only their bodies but also their eyes. Since these patients have difficulty gazing at specific visual stimuli or keeping their eyes open for a long time, they are unable to use the typical steady-state visual evoked potential (SSVEP)-based brain-computer interface (BCI) systems. In this study, we introduce a new paradigm for SSVEP-based BCI, which can be potentially suitable for disabled individuals with impaired oculomotor function. Approach. The proposed electroencephalography (EEG)-based BCI system allows users to express their binary intentions without needing to open their eyes. A pair of glasses with two light emitting diodes flickering at different frequencies was used to present visual stimuli to participants with their eyes closed, and we classified the recorded EEG patterns in the online experiments conducted with five healthy participants and one patient with severe amyotrophic lateral sclerosis (ALS). Main results. Through offline experiments performed with 11 participants, we confirmed that human SSVEP could be modulated by visual selective attention to a specific light stimulus penetrating through the eyelids. Furthermore, the recorded EEG patterns could be classified with accuracy high enough for use in a practical BCI system. After customizing the parameters of the proposed SSVEP-based BCI paradigm based on the offline analysis results, binary intentions of five healthy participants were classified in real time. The average information transfer rate of our online experiments reached 10.83 bits min-1. A preliminary online experiment conducted with an ALS patient showed a classification accuracy of 80%. Significance. The results of our offline and online experiments demonstrated the feasibility of our proposed SSVEP-based BCI paradigm. It is expected that our ‘eyes-closed’ SSVEP-based BCI system can be potentially used for communication of

  14. A featured-based strategy for stereovision matching in sensors with fish-eye lenses for forest environments.

    PubMed

    Herrera, Pedro Javier; Pajares, Gonzalo; Guijarro, Maria; Ruz, José J; Cruz, Jesús M; Montes, Fernando

    2009-01-01

    This paper describes a novel feature-based stereovision matching process based on a pair of omnidirectional images in forest stands acquired with a stereovision sensor equipped with fish-eye lenses. The stereo analysis problem consists of the following steps: image acquisition, camera modelling, feature extraction, image matching and depth determination. Once the depths of significant points on the trees are obtained, the growing stock volume can be estimated by considering the geometrical camera modelling, which is the final goal. The key steps are feature extraction and image matching. This paper is devoted solely to these two steps. At a first stage a segmentation process extracts the trunks, which are the regions used as features, where each feature is identified through a set of attributes of properties useful for matching. In the second step the features are matched based on the application of the following four well known matching constraints, epipolar, similarity, ordering and uniqueness. The combination of the segmentation and matching processes for this specific kind of sensors make the main contribution of the paper. The method is tested with satisfactory results and compared against the human expert criterion.

  15. A Featured-Based Strategy for Stereovision Matching in Sensors with Fish-Eye Lenses for Forest Environments

    PubMed Central

    Herrera, Pedro Javier; Pajares, Gonzalo; Guijarro, Maria; Ruz, José J.; Cruz, Jesús M.; Montes, Fernando

    2009-01-01

    This paper describes a novel feature-based stereovision matching process based on a pair of omnidirectional images in forest stands acquired with a stereovision sensor equipped with fish-eye lenses. The stereo analysis problem consists of the following steps: image acquisition, camera modelling, feature extraction, image matching and depth determination. Once the depths of significant points on the trees are obtained, the growing stock volume can be estimated by considering the geometrical camera modelling, which is the final goal. The key steps are feature extraction and image matching. This paper is devoted solely to these two steps. At a first stage a segmentation process extracts the trunks, which are the regions used as features, where each feature is identified through a set of attributes of properties useful for matching. In the second step the features are matched based on the application of the following four well known matching constraints, epipolar, similarity, ordering and uniqueness. The combination of the segmentation and matching processes for this specific kind of sensors make the main contribution of the paper. The method is tested with satisfactory results and compared against the human expert criterion. PMID:22303134

  16. A featured-based strategy for stereovision matching in sensors with fish-eye lenses for forest environments.

    PubMed

    Herrera, Pedro Javier; Pajares, Gonzalo; Guijarro, Maria; Ruz, José J; Cruz, Jesús M; Montes, Fernando

    2009-01-01

    This paper describes a novel feature-based stereovision matching process based on a pair of omnidirectional images in forest stands acquired with a stereovision sensor equipped with fish-eye lenses. The stereo analysis problem consists of the following steps: image acquisition, camera modelling, feature extraction, image matching and depth determination. Once the depths of significant points on the trees are obtained, the growing stock volume can be estimated by considering the geometrical camera modelling, which is the final goal. The key steps are feature extraction and image matching. This paper is devoted solely to these two steps. At a first stage a segmentation process extracts the trunks, which are the regions used as features, where each feature is identified through a set of attributes of properties useful for matching. In the second step the features are matched based on the application of the following four well known matching constraints, epipolar, similarity, ordering and uniqueness. The combination of the segmentation and matching processes for this specific kind of sensors make the main contribution of the paper. The method is tested with satisfactory results and compared against the human expert criterion. PMID:22303134

  17. Meeting report: the road to science-based policy - ESOF through the eyes of young scientists.

    PubMed

    Sinjab, Ansam; Nöske, Katharina

    2014-12-01

    Communication and common understanding between politicians, scientists, and the society can lead to evidence-based science policy, a core principle that guides high caliber research and open innovation for a sustainable future. PMID:25346005

  18. Meeting report: the road to science-based policy - ESOF through the eyes of young scientists.

    PubMed

    Sinjab, Ansam; Nöske, Katharina

    2014-12-01

    Communication and common understanding between politicians, scientists, and the society can lead to evidence-based science policy, a core principle that guides high caliber research and open innovation for a sustainable future.

  19. Improving eye safety in citrus harvest crews through the acceptance of personal protective equipment, community-based participatory research, social marketing, and community health workers.

    PubMed

    Tovar-Aguilar, J Antonio; Monaghan, Paul F; Bryant, Carol A; Esposito, Andrew; Wade, Mark; Ruiz, Omar; McDermott, Robert J

    2014-01-01

    For the last 10 years, the Partnership for Citrus Workers Health (PCWH) has been an evidence-based intervention program that promotes the adoption of protective eye safety equipment among Spanish-speaking farmworkers of Florida. At the root of this program is the systematic use of community-based preventive marketing (CBPM) and the training of community health workers (CHWs) among citrus harvester using popular education. CBPM is a model that combines the organizational system of community-based participatory research (CBPR) and the strategies of social marketing. This particular program relied on formative research data using a mixed-methods approach and a multilevel stakeholder analysis that allowed for rapid dissemination, effective increase of personal protective equipment (PPE) usage, and a subsequent impact on adoptive workers and companies. Focus groups, face-to-face interviews, surveys, participant observation, Greco-Latin square, and quasi-experimental tests were implemented. A 20-hour popular education training produced CHWs that translated results of the formative research to potential adopters and also provided first aid skills for eye injuries. Reduction of injuries is not limited to the use of safety glasses, but also to the adoption of timely intervention and regular eye hygiene. Limitations include adoption in only large companies, rapid decline of eye safety glasses without consistent intervention, technological limitations of glasses, and thorough cost-benefit analysis.

  20. Quadcopter flight control using a low-cost hybrid interface with EEG-based classification and eye tracking.

    PubMed

    Kim, Byung Hyung; Kim, Minho; Jo, Sungho

    2014-08-01

    We propose a wearable hybrid interface where eye movements and mental concentration directly influence the control of a quadcopter in three-dimensional space. This noninvasive and low-cost interface addresses limitations of previous work by supporting users to complete their complicated tasks in a constrained environment in which only visual feedback is provided. The combination of the two inputs augments the number of control commands to enable the flying robot to travel in eight different directions within the physical environment. Five human subjects participated in the experiments to test the feasibility of the hybrid interface. A front view camera on the hull of the quadcopter provided the only visual feedback to each remote subject on a laptop display. Based on the visual feedback, the subjects used the interface to navigate along pre-set target locations in the air. The flight performance was evaluated by comparing with a keyboard-based interface. We demonstrate the applicability of the hybrid interface to explore and interact with a three-dimensional physical space through a flying robot.

  1. Copula regression analysis of simultaneously recorded frontal eye field and inferotemporal spiking activity during object-based working memory.

    PubMed

    Hu, Meng; Clark, Kelsey L; Gong, Xiajing; Noudoost, Behrad; Li, Mingyao; Moore, Tirin; Liang, Hualou

    2015-06-10

    Inferotemporal (IT) neurons are known to exhibit persistent, stimulus-selective activity during the delay period of object-based working memory tasks. Frontal eye field (FEF) neurons show robust, spatially selective delay period activity during memory-guided saccade tasks. We present a copula regression paradigm to examine neural interaction of these two types of signals between areas IT and FEF of the monkey during a working memory task. This paradigm is based on copula models that can account for both marginal distribution over spiking activity of individual neurons within each area and joint distribution over ensemble activity of neurons between areas. Considering the popular GLMs as marginal models, we developed a general and flexible likelihood framework that uses the copula to integrate separate GLMs into a joint regression analysis. Such joint analysis essentially leads to a multivariate analog of the marginal GLM theory and hence efficient model estimation. In addition, we show that Granger causality between spike trains can be readily assessed via the likelihood ratio statistic. The performance of this method is validated by extensive simulations, and compared favorably to the widely used GLMs. When applied to spiking activity of simultaneously recorded FEF and IT neurons during working memory task, we observed significant Granger causality influence from FEF to IT, but not in the opposite direction, suggesting the role of the FEF in the selection and retention of visual information during working memory. The copula model has the potential to provide unique neurophysiological insights about network properties of the brain. PMID:26063909

  2. Longitudinal trends in use of targeted therapies for treatment of malignant neoplasms of the eye: a population-based study in Taiwan

    PubMed Central

    Hsu, Jason C; Gonzalez-Gonzalez, Luis A; Lu, Vicky H; Lu, Christine Y

    2016-01-01

    Objectives This study examined the recent trend in use and costs of antineoplastic agents for treatment of eye malignancies in Taiwan from 2009 to 2012. We also forecasted use and costs of targeted therapies up to and including year 2016 based on the current patterns. Design Retrospective observational study focusing on the usage of targeted therapies for treatment of eye malignancy. Setting The monthly claims data for eye malignancy-related antineoplastic agents were retrieved from Taiwan's National Health Insurance Research Database (2009–2012). Main outcome measures We calculated the number of prescriptions and costs for each class of medications, and analysed their time trends. In addition, using a time series design with ARIMA models, we estimated the market share by prescription volume and the proportion of costs for targeted therapies for year 2016. Results The market share by prescription volume of targeted therapies grew from 1.56% in 2009 to 9.98% in 2012 among all antineoplastic agents, and the proportion of costs for targeted therapies rose from 15.12% in 2009 to 58.88% in 2012. Especially, the proportion of costs for protein kinase inhibitors grew from 25.62% to 45.28% among all antineoplastic agents between 2010 and 2012. The market share by prescription volume and the proportion of costs for targeted therapies for treatment of eye malignancies were predicted to reach 27.33% and 91.39% by the fourth quarter in 2016, respectively. Conclusions This is the first study that examined and forecasted use and costs of targeted therapies for treatment of eye malignancies in Taiwan. Our findings indicate that, compared with other classes of drugs, targeted therapies are having a more and more relevant share among all treatment strategies for eye malignancies in Taiwan, and due to their high costs they are likely to cause great economic burden. PMID:27235298

  3. The Eyes Have It: A Problem-Based Learning Exercise in Molecular Evolution

    ERIC Educational Resources Information Center

    White, Harold B.

    2007-01-01

    Molecular evolution provides an interesting context in which to use problem-based learning because it integrates a variety of topics in biology, biochemistry, and molecular biology. This three-stage problem for advanced students deals with the structure, multiple functions, and properties of lactate dehydrogenase isozymes, and the related…

  4. Conveying Clinical Reasoning Based on Visual Observation via Eye-Movement Modelling Examples

    ERIC Educational Resources Information Center

    Jarodzka, Halszka; Balslev, Thomas; Holmqvist, Kenneth; Nystrom, Marcus; Scheiter, Katharina; Gerjets, Peter; Eika, Berit

    2012-01-01

    Complex perceptual tasks, like clinical reasoning based on visual observations of patients, require not only conceptual knowledge about diagnostic classes but also the skills to visually search for symptoms and interpret these observations. However, medical education so far has focused very little on how visual observation skills can be…

  5. Billie's eyes.

    PubMed

    Dunning, S E

    1993-03-01

    The author, a nurse, is personally opposed to abortion; however, her earlier encounter with a victim of an illegal abortion has prevented her from joining campaigns to reinstate bans on abortion rights. The woman, "Billie," presented to an inner-city Chicago hospital in 1970 with hemorrhaging. She had delayed going for treatment because she feared being imprisoned for having obtained an abortion. She rapidly entered septic shock, with hypotension, confusion, and hallucinations. Physicians removed her infected uterus and ovaries. Subsequent kidney failure necessitated the transfer of this young woman to another hospital where she could receive dialysis. The author was unable to obtain follow-up information on whether Billie survived. She remains haunted by the memory of Billie's wide, frightened eyes as she was placed in the ambulance. It is this memory, and the knowledge that desperate women like Billie will find someone, somewhere to perform an illegal abortion, that is behind the author's reluctant support for the right to choose.

  6. Synthesis and evaluation of simple naked-eye colorimetric chemosensors for anions based on azo dye-thiosemicarbazones

    NASA Astrophysics Data System (ADS)

    Radchatawedchakoon, Widchaya; Sangsuwan, Withsakorn; Kruanetr, Senee; Sakee, Uthai

    2014-03-01

    A series of novel, highly selective azo dye-thiosemicarbazones based anion sensors (3e-f) have been synthesized from the condensation reaction between thiosemicarbazide and six different azo salicylaldehydes. The structure of the sensors was confirmed by spectroscopic methods. The selectivity and sensitivity in the recognition for acetate anion over other anions such as fluoride, chloride, iodide and dihydrogenphosphate anions were determined by naked-eyes and UV-vis spectra. The color of the solution containing sensor had an obvious change from light yellow to orange only after the addition of acetate anion in aqueous solution (water/dimethylsulfoxide, 7:3, v/v) while other anions did not cause obvious color change. The anion recognition property of the receptor via proton-transfer is monitored by UV-vis titration and 1H NMR spectroscopy. Under condition in aqueous solution of sensor 3e (water/dimethylsulfoxide, 7:3, v/v), linearity range for the quantification of acetate anion was 1-22 μM and limit of detection (LOD) of acetate anion was 0.71 μM.

  7. Burn severity estimation using GeoEye imagery, object-based image analysis (OBIA), and Composite Burn Index (CBI) measurements

    NASA Astrophysics Data System (ADS)

    Dragozi, E.; Gitas, Ioannis Z.; Stavrakoudis, Dimitris G.; Minakou, C.

    2015-06-01

    Forest fires greatly influence the stability and functions of the forest ecosystems. The ever increasing need for accurate and detailed information regarding post-fire effects (burn severity) has led to several studies on the matter. In this study the combined use of Very High Resolution (VHR) satellite data (GeoEye), Objectbased image analysis (OBIA) and Composite Burn Index (CBI) measurements in estimating burn severity, at two different time points (2011 and 2012) is assessed. The accuracy of the produced maps was assessed and changes in burn severity between the two dates were detected using the post classification comparison approach. It was found that the produced burn severity map for 2011 was approximately 10% more accurate than that of 2012. This was mainly attributed to the increased heterogeneity of the study area in the second year, which led to an increased number of mixed class objects and consequently made it more difficult to spectrally discriminate between the severity classes. Following the post-classification analysis, the severity class changes were mainly attributed to the trees' ability to survive severe fire damage and sprout new leaves. Moreover, the results of the study suggest that when classifying CBI-based burn severity using VHR imagery it would be preferable to use images captured soon after the fire.

  8. Eye-Tracking Data

    PubMed Central

    Galesic, Mirta; Tourangeau, Roger; Couper, Mick P.; Conrad, Frederick G.

    2008-01-01

    Survey researchers since Cannell have worried that respondents may take various shortcuts to reduce the effort needed to complete a survey. The evidence for such shortcuts is often indirect. For instance, preferences for earlier versus later response options have been interpreted as evidence that respondents do not read beyond the first few options. This is really only a hypothesis, however, that is not supported by direct evidence regarding the allocation of respondent attention. In the current study, we used a new method to more directly observe what respondents do and do not look at by recording their eye movements while they answered questions in a Web survey. The eye-tracking data indicate that respondents do in fact spend more time looking at the first few options in a list of response options than those at the end of the list; this helps explain their tendency to select the options presented first regardless of their content. In addition, the eye-tracking data reveal that respondents are reluctant to invest effort in reading definitions of survey concepts that are only a mouse click away or paying attention to initially hidden response options. It is clear from the eye-tracking data that some respondents are more prone to these and other cognitive shortcuts than others, providing relatively direct evidence for what had been suspected based on more conventional measures. PMID:21253437

  9. Fly eye based sensor model and animation using matlab - biomed 2011.

    PubMed

    Anderson, Jeffrey R; Barrett, Steven F; Wright, Cameron H G

    2011-01-01

    A new optical sensor based on the common house fly, Musca domestica, has been under development for some time at the University of Wyoming. Each sensor consists of a series of photodiodes with overlapping Gaussian field of views. The photodiodes share a common facet lens. This type of sensor provides higher movement detection and resolution than can be obtained in current charged-couple detector (CCD) arrays that are commonly used in digital imaging systems. The purpose of this research is to aid in the application and development of the fly based sensor by creating a MATLAB simulation tool to model and study the response signals from various input stimuli. In particular, the sensor detection capability and limits for line, edge and pulse stimuli will be modeled, and analyzed. Increased knowledge of the detection characteristics and limits of this type of sensor will provide insight and guidance to determine possible sensor applications. The signal analysis makes use of the Gaussian profiles that are created in MATLAB. A user-selectable input signal can be applied, while observing the output signal. The information is animated, and plotted for study and analysis. This interactive MATLAB model is a powerful tool to help understand the complex interactions of the optical signals. This sensor configuration has a variety of applications in wheelchair odometry, power line detection by unmanned aerial systems (AES), high speed railroad line inspection, and remote building monitoring.

  10. Finding an Eye Care Professional

    MedlinePlus

    ... Information > Finding an Eye Care Professional Finding an Eye Care Professional Finding an Eye Care Professional PDF* The National Eye Institute does not provide referrals or recommend specific ...

  11. National Eye Institute

    MedlinePlus

    ... vision science and eye health fun with videos, optical illusions, and more. View the site Request for ... español NEI FAQs Eye Health Resources Studies, print materials and more. National Eye Health Education Program (NEHEP) ...

  12. Eye muscle repair - discharge

    MedlinePlus

    ... page: //medlineplus.gov/ency/patientinstructions/000111.htm Eye muscle repair - discharge To use the sharing features on ... enable JavaScript. You or your child had eye muscle repair surgery to correct eye muscle problems that ...

  13. Eye muscle repair - slideshow

    MedlinePlus

    ... page: //medlineplus.gov/ency/presentations/100062.htm Eye muscle repair - series—Normal anatomy To use the sharing ... the eyeball to the eye socket. The external muscles of the eye are found behind the conjunctiva. ...

  14. Fluorescent eye test (image)

    MedlinePlus

    The fluorescent eye test is useful in determining if there is a scratch or other problem with the surface ... has thoroughly covered the eye a cobalt blue light is then directed on the eye. The light ...

  15. Eye-gaze independent EEG-based brain-computer interfaces for communication

    NASA Astrophysics Data System (ADS)

    Riccio, A.; Mattia, D.; Simione, L.; Olivetti, M.; Cincotti, F.

    2012-08-01

    The present review systematically examines the literature reporting gaze independent interaction modalities in non-invasive brain-computer interfaces (BCIs) for communication. BCIs measure signals related to specific brain activity and translate them into device control signals. This technology can be used to provide users with severe motor disability (e.g. late stage amyotrophic lateral sclerosis (ALS); acquired brain injury) with an assistive device that does not rely on muscular contraction. Most of the studies on BCIs explored mental tasks and paradigms using visual modality. Considering that in ALS patients the oculomotor control can deteriorate and also other potential users could have impaired visual function, tactile and auditory modalities have been investigated over the past years to seek alternative BCI systems which are independent from vision. In addition, various attentional mechanisms, such as covert attention and feature-directed attention, have been investigated to develop gaze independent visual-based BCI paradigms. Three areas of research were considered in the present review: (i) auditory BCIs, (ii) tactile BCIs and (iii) independent visual BCIs. Out of a total of 130 search results, 34 articles were selected on the basis of pre-defined exclusion criteria. Thirteen articles dealt with independent visual BCIs, 15 reported on auditory BCIs and the last six on tactile BCIs, respectively. From the review of the available literature, it can be concluded that a crucial point is represented by the trade-off between BCI systems/paradigms with high accuracy and speed, but highly demanding in terms of attention and memory load, and systems requiring lower cognitive effort but with a limited amount of communicable information. These issues should be considered as priorities to be explored in future studies to meet users’ requirements in a real-life scenario.

  16. Eye-gaze independent EEG-based brain-computer interfaces for communication.

    PubMed

    Riccio, A; Mattia, D; Simione, L; Olivetti, M; Cincotti, F

    2012-08-01

    The present review systematically examines the literature reporting gaze independent interaction modalities in non-invasive brain-computer interfaces (BCIs) for communication. BCIs measure signals related to specific brain activity and translate them into device control signals. This technology can be used to provide users with severe motor disability (e.g. late stage amyotrophic lateral sclerosis (ALS); acquired brain injury) with an assistive device that does not rely on muscular contraction. Most of the studies on BCIs explored mental tasks and paradigms using visual modality. Considering that in ALS patients the oculomotor control can deteriorate and also other potential users could have impaired visual function, tactile and auditory modalities have been investigated over the past years to seek alternative BCI systems which are independent from vision. In addition, various attentional mechanisms, such as covert attention and feature-directed attention, have been investigated to develop gaze independent visual-based BCI paradigms. Three areas of research were considered in the present review: (i) auditory BCIs, (ii) tactile BCIs and (iii) independent visual BCIs. Out of a total of 130 search results, 34 articles were selected on the basis of pre-defined exclusion criteria. Thirteen articles dealt with independent visual BCIs, 15 reported on auditory BCIs and the last six on tactile BCIs, respectively. From the review of the available literature, it can be concluded that a crucial point is represented by the trade-off between BCI systems/paradigms with high accuracy and speed, but highly demanding in terms of attention and memory load, and systems requiring lower cognitive effort but with a limited amount of communicable information. These issues should be considered as priorities to be explored in future studies to meet users' requirements in a real-life scenario.

  17. Validation of a paleo river system derived by ground based electromagnetic induction measurements with satellite based RapidEye images

    NASA Astrophysics Data System (ADS)

    Rudolph, Sebastian; von Hebel, Christian; Ali, Mohammed; Stadler, Anja; Herbst, Michael; Montzka, Carsten; Pätzold, Stefan; Weihermüller, Lutz; van der Kruk, Jan; Vereecken, Harry

    2013-04-01

    Morphological remnants of an inactive river system that has been filled by younger sediments can provide datable proxies about past climatic conditions. However, sediment composition of their infillings is a challenge for agriculture, in particular for precision agriculture. Differential crop development and yield reduction are often a consequence of lateral and vertical textural inhomogeneities. Several studies have shown that buried river systems can be traced by the use of remote sensing. However, the appearance of crop marks strongly depends on environmental conditions, and therefore, the reliance of remotely acquired data can become time and cost expensive. Soil physical properties which are related to textural differences can be mapped fast and cost-effective by the use of near surface geophysics. Especially electromagnetic induction (EMI), which measures soil apparent conductivity (ECa), has become a tool of choice to characterize large areas in high resolution. The introduction of multiple coil EMI systems as well as the quantification of respective measurements enables a reliable multilayer inversion. The aim of this study was to map a postglacial river system on agricultural fields and to mark out buried remains such as trenches and bomb craters of World War II. In summer 2012 ten fields (17 ha) were mapped with the CMD MiniExplorer, a multiple coil EMI system especially appropriate for near surface applications, after the harvest of winter wheat and sugar beet. At elevated sandy sites meander like patterns with higher conductivity were mapped. ECa measurements were verified by textural data taken from directed soil samples and vertical ECa logs. Sediment thickness was evaluated on soil cores and electrical resistivity tomography (ERT) transects. Furthermore, ERT quantified ECa measurements were correlated with satellite as well as destructive derived leaf area index (LAI) measurements. In 3 of 71 LAI maps derived by multispectral RapidEye imagery crop

  18. Numerical study on statistical properties of speckle pattern in laser projection display based on human eye model

    NASA Astrophysics Data System (ADS)

    Cui, Zhe; Wang, Anting; Ma, Qianli; Ming, Hai

    2013-12-01

    In this paper, the laser speckle pattern on human retina for a laser projection display is simulated. By introducing a specific eye model `Indiana Eye', the statistical properties of the laser speckle are numerical investigated. The results show that the aberrations of human eye (mostly spherical and chromatic) will decrease the speckle contrast felt by people. When the wavelength of the laser source is 550 nm (green), people will feel the strongest speck pattern and the weakest when the wavelength is 450 nm (blue). Myopia and hyperopia will decrease the speckle contrast by introducing large spherical aberrations. Although aberration is good for speckle reduction, but it will degrade the imaging capability of the eye. The results show that laser source (650 nm) will have the best image quality on the retina. At last, we compare the human eye with an aberration-free imaging system. Both the speckle contrast and the image quality appear different behavior in these two imaging systems. The results are useful when a standardized measurement procedure for speckle contrast needs to be built.

  19. Cytotoxicity screening of surfactant-based shampoos using a multiwell fluorescence scanner: Correlation with Draize eye scores.

    PubMed

    Merrick, P; Nieminen, A L; Harper, R A; Herman, B; Lemasters, J J

    1992-11-01

    The irritancy potential of seven shampoos was evaluated by a rapid cytotoxicity assay in cultured human keratinocytes and rat hepatocytes. Loss of cell viability was estimated from increases in propidium iodide fluorescence measured using a multiwell fluorescence scanner. The concentration of shampoo causing a 50% loss of cell viability after 15 min of incubation (V(50)) was determined by probit analysis. Log V(50) measured in human keratinocytes showed a strong negative correlation (r = -0.95; P <0.001) with Draize eye scores in rabbits. Log V(50) measured in rat hepatocytes did not show a statistically significant correlation with Draize eye scores. The results indicate that cytotoxicity screening of human keratinocytes using propidium iodide and a multiwell fluorescence scanner is highly predictive of Draize eye scores for surfactant-containing shampoos.

  20. Assessment of IrisPlex-based multiplex for eye and skin color prediction with application to a Portuguese population.

    PubMed

    Dario, Paulo; Mouriño, Helena; Oliveira, Ana Rita; Lucas, Isabel; Ribeiro, Teresa; Porto, Maria João; Costa Santos, Jorge; Dias, Deodália; Corte Real, Francisco

    2015-11-01

    DNA phenotyping research is one of the most emergent areas of forensic genetics. Predictions of externally visible characteristics are possible through analysis of single nucleotide polymorphisms. These tools can provide police with "intelligence" in cases where there are no obvious suspects and unknown biological samples found at the crime scene do not result in any criminal DNA database hits. IrisPlex, an eye color prediction assay, revealed high prediction rates for blue and brown eye color in European populations. However, this is less predictive in some non-European populations, probably due to admixing. When compared to other European countries, Portugal has a relatively admixed population, resulting from a genetic influx derived from its proximity to and historical relations with numerous African territories. The aim of this work was to evaluate the utility of IrisPlex in the Portuguese population. Furthermore, the possibility of supplementing this multiplex with additional markers to also achieve skin color prediction within this population was evaluated. For that, IrisPlex was augmented with additional SNP loci. Eye and skin color prediction was estimated using the multinomial logistic regression and binomial logistic regression models, respectively. The results demonstrated eye color prediction accuracies of the IrisPlex system of 90 and 60% for brown and blue eye color, respectively, and 77% for intermediate eye color, after allele frequency adjustment. With regard to skin color, it was possible to achieve a prediction accuracy of 93%. In the future, phenotypic determination multiplexes must include additional loci to permit skin color prediction as presented in this study as this can be an advantageous tool for forensic investigation. PMID:26289415

  1. Assessment of IrisPlex-based multiplex for eye and skin color prediction with application to a Portuguese population.

    PubMed

    Dario, Paulo; Mouriño, Helena; Oliveira, Ana Rita; Lucas, Isabel; Ribeiro, Teresa; Porto, Maria João; Costa Santos, Jorge; Dias, Deodália; Corte Real, Francisco

    2015-11-01

    DNA phenotyping research is one of the most emergent areas of forensic genetics. Predictions of externally visible characteristics are possible through analysis of single nucleotide polymorphisms. These tools can provide police with "intelligence" in cases where there are no obvious suspects and unknown biological samples found at the crime scene do not result in any criminal DNA database hits. IrisPlex, an eye color prediction assay, revealed high prediction rates for blue and brown eye color in European populations. However, this is less predictive in some non-European populations, probably due to admixing. When compared to other European countries, Portugal has a relatively admixed population, resulting from a genetic influx derived from its proximity to and historical relations with numerous African territories. The aim of this work was to evaluate the utility of IrisPlex in the Portuguese population. Furthermore, the possibility of supplementing this multiplex with additional markers to also achieve skin color prediction within this population was evaluated. For that, IrisPlex was augmented with additional SNP loci. Eye and skin color prediction was estimated using the multinomial logistic regression and binomial logistic regression models, respectively. The results demonstrated eye color prediction accuracies of the IrisPlex system of 90 and 60% for brown and blue eye color, respectively, and 77% for intermediate eye color, after allele frequency adjustment. With regard to skin color, it was possible to achieve a prediction accuracy of 93%. In the future, phenotypic determination multiplexes must include additional loci to permit skin color prediction as presented in this study as this can be an advantageous tool for forensic investigation.

  2. Eye movement monitoring of memory.

    PubMed

    Ryan, Jennifer D; Riggs, Lily; McQuiggan, Douglas A; McQuiggan, Doug

    2010-08-15

    Explicit (often verbal) reports are typically used to investigate memory (e.g. "Tell me what you remember about the person you saw at the bank yesterday."), however such reports can often be unreliable or sensitive to response bias, and may be unobtainable in some participant populations. Furthermore, explicit reports only reveal when information has reached consciousness and cannot comment on when memories were accessed during processing, regardless of whether the information is subsequently accessed in a conscious manner. Eye movement monitoring (eye tracking) provides a tool by which memory can be probed without asking participants to comment on the contents of their memories, and access of such memories can be revealed on-line. Video-based eye trackers (either head-mounted or remote) use a system of cameras and infrared markers to examine the pupil and corneal reflection in each eye as the participant views a display monitor. For head-mounted eye trackers, infrared markers are also used to determine head position to allow for head movement and more precise localization of eye position. Here, we demonstrate the use of a head-mounted eye tracking system to investigate memory performance in neurologically-intact and neurologically-impaired adults. Eye movement monitoring procedures begin with the placement of the eye tracker on the participant, and setup of the head and eye cameras. Calibration and validation procedures are conducted to ensure accuracy of eye position recording. Real-time recordings of X,Y-coordinate positions on the display monitor are then converted and used to describe periods of time in which the eye is static (i.e. fixations) versus in motion (i.e., saccades). Fixations and saccades are time-locked with respect to the onset/offset of a visual display or another external event (e.g. button press). Experimental manipulations are constructed to examine how and when patterns of fixations and saccades are altered through different types of prior

  3. Evaluating Experience-Based Geologic Field Instruction: Lessons Learned from A Large-Scale Eye-Tracking Experiment

    NASA Astrophysics Data System (ADS)

    Tarduno, J. A.; Walders, K.; Bono, R. K.; Pelz, J.; Jacobs, R.

    2015-12-01

    A course centered on experience-based learning in field geology has been offered ten times at the University of Rochester. The centerpiece of the course is a 10-day field excursion to California featuring a broad cross-section of the geology of the state, from the San Andreas Fault to Death Valley. Here we describe results from a large-scale eye-tracking experiment aimed at understanding how experts and novices acquire visual geologic information. One ultimate goal of the project is to determine whether expert gaze patterns can be quantified to improve the instruction of beginning geology students. Another goal is to determine if aspects of the field experience can be transferred to the classroom/laboratory. Accordingly, ultra-high resolution segmented panoramic images have been collected at key sites visited during the field excursion. We have found that strict controls are needed in the field to obtain meaningful data; this often involves behavior atypical of geologists (e.g. limiting the field of view prior to data collection and placing time limits on scene viewing). Nevertheless some general conclusions can be made from a select data set. After an initial quick search, experts tend to exhibit scanning behavior that appears to support hypothesis testing. Novice fixations appear to define a scattered search pattern and/or one distracted by geologic noise in a scene. Noise sources include modern erosion features and vegetation. One way to quantify noise is through the use of saliency maps. With the caveat that our expert data set is small, our preliminary analysis suggests that experts tend to exhibit top-down behavior (indicating hypothesis driven responses) whereas novices show bottom-up gaze patterns, influenced by more salient features in a scene. We will present examples and discuss how these observations might be used to improve instruction.

  4. A Population-Based Assessment of the Agreement Between Grading of Goniophotographic Images and Gonioscopy in the Chinese-American Eye Study (CHES)

    PubMed Central

    Murakami, Yohko; Wang, Dandan; Burkemper, Bruce; Lin, Shan C.; Varma, Rohit

    2016-01-01

    Purpose To compare grading of goniophotographic images and gonioscopy in assessing the iridocorneal angle. Methods In a population-based, cross-sectional study, participants underwent gonioscopy and goniophotographic imaging during the same visit. The iridocorneal angle was classified as closed if the posterior trabecular meshwork could not be seen. A single masked observer graded the goniophotographic images, and each eye was classified as having angle closure based on the number of closed quadrants. Agreement between the methods was analyzed by calculating kappa (κ) and first-order agreement coefficient (AC1) statistics and comparison of area under receiver operating characteristic curves (AUC). Results A total of 4149 Chinese Americans (3994 eyes) were included in this study. The agreement for angle closure diagnosis between gonioscopy and EyeCam was moderate to excellent (κ = 0.60, AC1 0.90, AUC 0.76–0.80). Conclusions Detection of iridocorneal angle closure based on goniophotographic imaging shows moderate to very good agreement with angle closure assessment using gonioscopy. PMID:27571018

  5. Prediction of eye irritation potential of surfactant-based rinse-off personal care formulations by the bovine corneal opacity and permeability (BCOP) assay.

    PubMed

    Cater, Kathleen C; Harbell, John W

    2006-01-01

    Evaluation of eye irritation potential is a routine part of product safety testing. Many companies have elected to use in vitro methods for this evaluation. We used the bovine corneal opacity and permeability (BCOP) assay for the prediction of the eye irritation potential of surfactant-based rinse-off personal care formulations in this study because of its positive performance in previous studies (1), and its potential to measure depth of injury through histological evaluation. The BCOP uses isolated corneas maintained in short-term organ culture and measures changes in opacity and epithelial barrier integrity (as determined by fluorescein passage through the cornea). Surfactants (anionic and nonionic) used in personal care formulations induce only small increases in direct opacity but the degree of epithelial damage is reflected in permeability measurement (OD490). The permeability measurement is the primary endpoint for this class of products. Marketed liquid hand soap was selected as the benchmark due to extensive in vivo and market history data. Using the liquid hand soap, a 25% v/v aqueous dilution with a 30-minute exposure produced the optimal resolution. A series of products with known in vivo eye irritation scores were evaluated to establish a prediction model. Histological evaluation was used to compare the degree of tissue damage to the permeability scores. Based on the permeability scores and histological review, the testing protocol for a surfactant-based rinse-off personal care formulation was developed using a 25% v/v aqueous dilution, a 30-minute exposure, concurrent testing of the benchmark control, and use of permeability measurements as the endpoint for the evaluation of eye irritation potential.

  6. Developmental validation of the HIrisPlex system: DNA-based eye and hair colour prediction for forensic and anthropological usage.

    PubMed

    Walsh, Susan; Chaitanya, Lakshmi; Clarisse, Lindy; Wirken, Laura; Draus-Barini, Jolanta; Kovatsi, Leda; Maeda, Hitoshi; Ishikawa, Takaki; Sijen, Titia; de Knijff, Peter; Branicki, Wojciech; Liu, Fan; Kayser, Manfred

    2014-03-01

    Forensic DNA Phenotyping or 'DNA intelligence' tools are expected to aid police investigations and find unknown individuals by providing information on externally visible characteristics of unknown suspects, perpetrators and missing persons from biological samples. This is especially useful in cases where conventional DNA profiling or other means remain non-informative. Recently, we introduced the HIrisPlex system, capable of predicting both eye and hair colour from DNA. In the present developmental validation study, we demonstrate that the HIrisPlex assay performs in full agreement with the Scientific Working Group on DNA Analysis Methods (SWGDAM) guidelines providing an essential prerequisite for future HIrisPlex applications to forensic casework. The HIrisPlex assay produces complete profiles down to only 63 pg of DNA. Species testing revealed human specificity for a complete HIrisPlex profile, while only non-human primates showed the closest full profile at 20 out of the 24 DNA markers, in all animals tested. Rigorous testing of simulated forensic casework samples such as blood, semen, saliva stains, hairs with roots as well as extremely low quantity touch (trace) DNA samples, produced complete profiles in 88% of cases. Concordance testing performed between five independent forensic laboratories displayed consistent reproducible results on varying types of DNA samples. Due to its design, the assay caters for degraded samples, underlined here by results from artificially degraded DNA and from simulated casework samples of degraded DNA. This aspect was also demonstrated previously on DNA samples from human remains up to several hundreds of years old. With this paper, we also introduce enhanced eye and hair colour prediction models based on enlarged underlying databases of HIrisPlex genotypes and eye/hair colour phenotypes (eye colour: N = 9188 and hair colour: N = 1601). Furthermore, we present an online web-based system for individual eye and hair colour

  7. A software module for implementing auditory and visual feedback on a video-based eye tracking system

    NASA Astrophysics Data System (ADS)

    Rosanlall, Bharat; Gertner, Izidor; Geri, George A.; Arrington, Karl F.

    2016-05-01

    We describe here the design and implementation of a software module that provides both auditory and visual feedback of the eye position measured by a commercially available eye tracking system. The present audio-visual feedback module (AVFM) serves as an extension to the Arrington Research ViewPoint EyeTracker, but it can be easily modified for use with other similar systems. Two modes of audio feedback and one mode of visual feedback are provided in reference to a circular area-of-interest (AOI). Auditory feedback can be either a click tone emitted when the user's gaze point enters or leaves the AOI, or a sinusoidal waveform with frequency inversely proportional to the distance from the gaze point to the center of the AOI. Visual feedback is in the form of a small circular light patch that is presented whenever the gaze-point is within the AOI. The AVFM processes data that are sent to a dynamic-link library by the EyeTracker. The AVFM's multithreaded implementation also allows real-time data collection (1 kHz sampling rate) and graphics processing that allow display of the current/past gaze-points as well as the AOI. The feedback provided by the AVFM described here has applications in military target acquisition and personnel training, as well as in visual experimentation, clinical research, marketing research, and sports training.

  8. The Feasibility of Capturing Learner Interactions Based on Logs Informed by Eye-Tracking and Remote Observation Studies

    ERIC Educational Resources Information Center

    San Diego, Jonathan P.; McAndrew, Patrick

    2009-01-01

    Two small studies, one an "eye-tracking" study and the other a "remote observation" study, have been conducted to investigate ways to identify two kinds of online learner interactions: users flicking through the web pages in "browsing" action, and users engaging with the content of a page in "learning" action. The video data from four participants…

  9. Eating for Your Eyes

    ERIC Educational Resources Information Center

    Stastny, Sherri Nordstrom; Garden-Robinson, Julie

    2011-01-01

    An educational program targeting older adults was developed to increase knowledge regarding nutrition and eye health. With age, the chance for eye disease increases, so prevention is critical. The Eating for Your Eyes program has promoted behavior changes regarding eye health among the participants. This program is easily replicated and use is…

  10. Grader agreement, and sensitivity and specificity of digital photography in a community optometry-based diabetic eye screening program

    PubMed Central

    Sellahewa, Luckni; Simpson, Craig; Maharajan, Prema; Duffy, John; Idris, Iskandar

    2014-01-01

    Background Digital retinal photography with mydriasis is the preferred modality for diabetes eye screening. The purpose of this study was to evaluate agreement in grading levels between primary and secondary graders and to calculate their sensitivity and specificity for identifying sight-threatening disease in an optometry-based retinopathy screening program. Methods This was a retrospective study using data from 8,977 patients registered in the North Nottinghamshire retinal screening program. In all cases, the ophthalmology diagnosis was used as the arbitrator and considered to be the gold standard. Kappa statistics were used to evaluate the level of agreement between graders. Results Agreement between primary and secondary graders was 51.4% and 79.7% for detecting no retinopathy (R0) and background retinopathy (R1), respectively. For preproliferative (R2) and proliferative retinopathy (R3) at primary grading, agreement between the primary and secondary grader was 100%. Where there was disagreement between the primary and secondary grader for R1, only 2.6% (n=41) were upgraded by an ophthalmologist. The sensitivity and specificity for detecting R3 was 78.2% and 98.1%, respectively. None of the patients upgraded from any level of retinopathy to R3 required photocoagulation therapy. The observed kappa between the primary and secondary grader was 0.3223 (95% confidence interval 0.2937–0.3509), ie, fair agreement, and between the primary grader and ophthalmology for R3 was 0.5667 (95% confidence interval 0.4557–0.6123), ie, moderate agreement. Conclusion These data provide information on the safety of a community optometry-based retinal screening program for screening as a primary and as a secondary grader. The level of agreement between the primary and secondary grader at a higher level of retinopathy (R2 and R3) was 100%. Sensitivity and specificity for R3 were 78.2% and 98.1%, respectively. None of the false-negative results required photocoagulation therapy

  11. Eye Injury Prevention for the Pediatric Population.

    PubMed

    Hoskin, Annette K; Philip, Swetha S; Yardley, Anne-Marie E; Mackey, David A

    2016-05-01

    Each year an estimated 3.3 to 5.7 million pediatric eye injuries occur worldwide. It is widely reported that 90% of ocular injuries are preventable. Our aim was to identify legislation and policies, education, and mandatory eye protection strategies that have successfully contributed to reducing rates of children's eye injuries. A literature search was conducted using the terms "pediatric" or "children" or "adolescent" and "ocular" or "eye" and "protection" or "injury prevention." Articles were retrieved based on titles and abstracts and assessed in the context of our research question. Strategies identified aimed at reducing ocular trauma fell into 3 broad categories: legislation and policies, education, and personal eye protection. Policies including restrictions on the sale and supply of certain consumer products, mandatory vehicle seatbelts, and laminated windscreens in vehicles have assisted in reducing children's eye injuries. Educational tools aimed at children and their caregivers have been effective in changing attitudes to eye health and safety. Effective pediatric eye injury prevention systems require a multifactorial approach combining legislation, policies, standards, education, and personal eye protection to limit exposure to ocular hazards. A paucity of standardized measurement and lack of funding have limited advances in the field of children's eye injury prevention. Improved eye injury surveillance and research funding along with collaboration with health care providers are important components for strategies to prevent pediatric ocular trauma. PMID:27183290

  12. Choroidal vascularity index as a measure of vascular status of the choroid: Measurements in healthy eyes from a population-based study

    NASA Astrophysics Data System (ADS)

    Agrawal, Rupesh; Gupta, Preeti; Tan, Kara-Anne; Cheung, Chui Ming Gemmy; Wong, Tien-Yin; Cheng, Ching-Yu

    2016-02-01

    The vascularity of the choroid has been implicated in the pathogenesis of various eye diseases. To date, no established quantifiable parameters to estimate vascular status of the choroid exists. Choroidal vascularity index (CVI) may potentially be used to assess vascular status of the choroid. We aimed to establish normative database for CVI and identify factors associated with CVI in healthy eyes. In this population-based study on 345 healthy eyes, choroidal enhanced depth imaging optical coherence tomography scans were segmented by modified image binarization technique. Total subfoveal choroidal area (TCA) was segmented into luminal (LA) and stromal (SA) area. CVI was calculated as the proportion of LA to TCA. Linear regression was used to identify ocular and systemic factors associated with CVI and subfoveal choroidal thickness (SFCT). Subfoveal CVI ranged from 60.07 to 71.27% with a mean value of 65.61 ± 2.33%. CVI was less variable than SFCT (coefficient of variation for CVI was 3.55 vs 40.30 for SFCT). Higher CVI was associated with thicker SFCT, but not associated with most physiological variables. CVI was elucidated as a significant determinant of SFCT. While SFCT was affected by many factors, CVI remained unaffected suggesting CVI to be a more robust marker of choroidal diseases.

  13. Stability of the memory of eye position in a recurrent network of conductance-based model neurons.

    PubMed

    Seung, H S; Lee, D D; Reis, B Y; Tank, D W

    2000-04-01

    Studies of the neural correlates of short-term memory in a wide variety of brain areas have found that transient inputs can cause persistent changes in rates of action potential firing, through a mechanism that remains unknown. In a premotor area that is responsible for holding the eyes still during fixation, persistent neural firing encodes the angular position of the eyes in a characteristic manner: below a threshold position the neuron is silent, and above it the firing rate is linearly related to position. Both the threshold and linear slope vary from neuron to neuron. We have reproduced this behavior in a biophysically plausible network model. Persistence depends on precise tuning of the strength of synaptic feedback, and a relatively long synaptic time constant improves the robustness to mistuning.

  14. Novel automatic eye detection and tracking algorithm

    NASA Astrophysics Data System (ADS)

    Ghazali, Kamarul Hawari; Jadin, Mohd Shawal; Jie, Ma; Xiao, Rui

    2015-04-01

    The eye is not only one of the most complex but also the most important sensory organ of the human body. Eye detection and eye tracking are basement and hot issue in image processing. A non-invasive eye location and eye tracking is promising for hands-off gaze-based human-computer interface, fatigue detection, instrument control by paraplegic patients and so on. For this purpose, an innovation work frame is proposed to detect and tracking eye in video sequence in this paper. The contributions of this work can be divided into two parts. The first contribution is that eye filters were trained which can detect eye location efficiently and accurately without constraints on the background and skin colour. The second contribution is that a framework of tracker based on sparse representation and LK optic tracker were built which can track eye without constraint on eye status. The experimental results demonstrate the accuracy aspects and the real-time applicability of the proposed approach.

  15. Lens of Eye Dosimetry

    SciTech Connect

    Mallett, Michael Wesley

    2015-03-23

    An analysis of LANL occupational dose measurements was made with respect to lens of eye dose (LOE), in particular, for plutonium workers. Table 1 shows the reported LOE as a ratio of the “deep” (photon only) and “deep+neutron” dose for routine monitored workers at LANL for the past ten years. The data compares the mean and range of these values for plutonium workers* and non-routine plutonium workers. All doses were reported based on measurements with the LANL Model 8823 TLD.

  16. Factors Associated with Awareness, Attitudes and Practices Regarding Common Eye Diseases in the General Population in a Rural District in Bangladesh: The Bangladesh Population-based Diabetes and Eye Study (BPDES)

    PubMed Central

    Islam, Fakir M. Amirul; Chakrabarti, Rahul; Islam, Silvia Z.; Finger, Robert P.; Critchley, Christine

    2015-01-01

    Background To assess the awareness, attitudes, and practices associated with common eye diseases and eye care utilization in a rural district of Bangladesh. Methods Data were collected using a multilevel cluster random sampling technique from 3104 adults aged ≥30 years from the Banshgram union with a questionnaire assessing the awareness, attitudes and practice about diabetes and common eye diseases, educational attainment, socio-economic status, and medical history. Results Participants were aged between 30 and 89 years with a mean (SD) age of 51 (12) years and 65% were female. The majority of participants had heard of cataracts (90%), trachoma (86%) and Pterygium (84%), yet only 4% had heard of diabetic retinopathy (DR), 7% of glaucoma and 8% of Age-related macular degeneration (AMD). However, 58% of participants did not know vision loss could be prevented. Factors associated with lower awareness regarding common eye diseases were increasing age, lack of formal schooling, and lower socio-economic status. A lower proportion (57%) of people with no schooling compared to those who had attained at least secondary school certificate education (72%) reported that they knew that vision loss could be prevented (p<0.001). Overall 51% of people had heard of at least six (67%) out of nine items relating to awareness of common eye diseases. This included 41% of participants aged 65 years or older compared to 61% of those aged 30–35 years (p<0.001). Only 4% had an eye check at least once a year and higher education and better SES were associated with higher frequency of eye checks. Conclusions In rural Bangladesh awareness of cataract, trachoma and pterygium was good but limited in relation to the potentially blinding conditions of glaucoma, DR, and AMD. The results show a large gap between public awareness and treatment practices about common eye diseases. Public health promotion should be designed to address these knowledge gaps. PMID:26200458

  17. Carotenoid-based bill and eye ring coloration as honest signals of condition: an experimental test in the red-legged partridge ( Alectoris rufa)

    NASA Astrophysics Data System (ADS)

    Pérez-Rodríguez, Lorenzo; Viñuela, Javier

    2008-09-01

    Carotenoid pigments cannot be synthesized by vertebrates but must be ingested through the diet. As they seem to be a limited resource, carotenoid-based ornaments are particularly interesting as possible honest signals of individual quality, in particular of foraging efficiency and nutritional status. Some studies have demonstrated the condition dependence of carotenoid-based plumage in birds. However, many other carotenoid-pigmented bare parts (i.e. skin, caruncles, bills, cere, and tarsi) are present in birds but, in comparison with plumage, little is known about these traits as indicators of individual quality. Here, we show that the eye ring pigmentation and bill redness of the red-legged partridge ( Alectoris rufa) are positively associated to body condition and recent changes in body mass. Also, we found a negative relationship between these two traits and heterophil-to-lymphocyte ratio, an indicator of physiological stress (the relationship with bill redness being significant only for males). In an experiment, we found that after a period of reduction in food intake (with the consequent loss of body mass), food-restricted birds showed lower eye ring pigmentation than ad-libitum-fed birds. Therefore, different ornaments seem to reflect changes in body condition but at different speeds or intensities (eye ring, a fleshy ornament, appears to respond more rapidly to changes in the nutritional status than a keratinized structure as the bill). These results indicate that carotenoid-based ornaments are condition-dependent traits in the red-legged partridge, being therefore susceptible to be employed as honest signals of quality in sexual selection.

  18. Diabetic Eye Problems

    MedlinePlus

    ... too high. Over time, this can damage your eyes. The most common problem is diabetic retinopathy. It ... light-sensitive tissue at the back of your eye. You need a healthy retina to see clearly. ...

  19. Diabetes - eye care

    MedlinePlus

    Diabetic retinopathy - care ... until the problem is very bad. Your health care provider can catch problems early if you get ... doctor (ophthalmologist). Choose an eye doctor who takes care of people with diabetes. Your eye exam may ...

  20. Diabetes and eye disease

    MedlinePlus

    ... the eye that can lead to blindness Macular edema: blurry vision due to fluid leaking into the ... in your retina (neovascularization) or you develop macular edema, treatment is usually needed. Eye surgery is the ...

  1. Eye Injuries (For Parents)

    MedlinePlus

    ... and comfortable as possible until help arrives. continue Chemical Exposure Many chemicals, even those found around the house, can damage an eye. If your child gets a chemical in the eye and you know what it ...

  2. Eye Injuries at Work

    MedlinePlus

    ... Bureau of Labor Statistics, more than 20,000 workplace eye injuries happen each year. Injuries on the job often ... Occupational Safety and Health Administration (OSHA) reports that workplace eye injuries cost an estimated $300 million a year in ...

  3. What Is Dry Eye?

    MedlinePlus

    ... Our Sites EyeWiki International Society of Refractive Surgery Museum of Vision Subspecialties Cataract/Anterior Segment Comprehensive Ophthalmology ... Our Sites EyeWiki International Society of Refractive Surgery Museum of Vision Subspecialties Cataract/Anterior Segment Comprehensive Ophthalmology ...

  4. Dwarf Eye Disorder

    ERIC Educational Resources Information Center

    Science Teacher, 2005

    2005-01-01

    Johns Hopkins researchers at the Wilmer Eye Institute have discovered what appears to be the first human gene mutation that causes extreme farsightedness. The researchers report that nanophthalmos, Greek for "dwarf eye," is a rare, potentially blinding disorder caused by an alteration in a gene called MFRP that helps control eye growth and…

  5. Eye - foreign object in

    MedlinePlus

    ... to gently flush it out with water or eye drops. If that does not work, try touching a second cotton-tipped swab to the object to remove it. If the object is on the white of the eye, try gently rinsing the eye with water or ...

  6. Automatic emotional expression analysis from eye area

    NASA Astrophysics Data System (ADS)

    Akkoç, Betül; Arslan, Ahmet

    2015-02-01

    Eyes play an important role in expressing emotions in nonverbal communication. In the present study, emotional expression classification was performed based on the features that were automatically extracted from the eye area. Fırst, the face area and the eye area were automatically extracted from the captured image. Afterwards, the parameters to be used for the analysis through discrete wavelet transformation were obtained from the eye area. Using these parameters, emotional expression analysis was performed through artificial intelligence techniques. As the result of the experimental studies, 6 universal emotions consisting of expressions of happiness, sadness, surprise, disgust, anger and fear were classified at a success rate of 84% using artificial neural networks.

  7. Shack-Hartmann-based objective straylight assessment of the human eye in an increased scattering angle range

    NASA Astrophysics Data System (ADS)

    Schramm, Stefan; Schikowski, Patrick; Lerm, Elena; Kaeding, André; Haueisen, Jens; Baumgarten, Daniel

    2016-07-01

    Objective measurement of straylight in the human eye with a Shack-Hartmann (SH) wavefront aberrometer is limited in imaging angle. We propose a measurement principle and a point spread function (PSF) reconstruction algorithm to overcome this limitation. In our optical setup, a variable stop replaces the stop conventionally used to suppress reflections and scatter in SH aberrometers. We record images with 21 diameters of the stop. From each SH image, the average intensity of the pupil is computed and normalized. The intensities represent integral values of the PSF. We reconstruct the PSF, which is the derivative of the intensities with respect to the visual angle. A modified Stiles Holladay approximation is fitted to the reconstructed PSF, resulting in a straylight parameter. A proof-of-principle study was carried out on eight healthy young volunteers. Scatter filters were positioned in front of the volunteers' eyes to simulate straylight. The straylight parameter was compared to the C-Quant measurements and the filter values. The PSF parameter shows strong correlation with the density of the filters and a linear relation to the C-Quant straylight parameter. Our measurement and reconstruction techniques allow for objective straylight analysis of visual angles up to 4 deg.

  8. Calibration of an eye oximeter with a dynamic eye phantom

    NASA Astrophysics Data System (ADS)

    Nabili, A.; Bardakci, D.; Helling, K.; Matyas, C.; Muro, S.; Ramella-Roman, J. C.

    2008-02-01

    Measurements of oxygen saturation and flow in the retina can yield information about the eye health and the onset of eye pathologies such as Diabetic Retinopathy. Recently we have realized an instrument capable of measuring oxygenation in the retina using six different wavelengths and capable of measuring blood flow using speckle-based techniques. The calibration of such instrument is particularly difficult due to the layered structure of the eye and the lack of alternative measurement techniques. For this purpose we have realized an in vitro model of the human eye. The artificial eye is composed of four layers: the retina vessels, the choroids, the retinal pigmented epithelium (RPE), and the sclera. The retina vessels are modeled with 150 μm tube connected to a micro-pump delivering 34 μl/min. The micro-tube, the pump, and a blood reservoir were connected in a closed circulatory system; blood oxygenation in the vessel could be modified using an external oxygen reservoir. The optical properties of all other layers were mimicked using titanium dioxide as a scatterer and ink as an absorber. The absorption coefficient μa and the scattering coefficient µs of these layers were independently measured using an integrating sphere. Absorption and scattering coefficient of all layers were modified before experimental measurements and a Monte Carlo program was finally used to model the experimental results.

  9. Panel-based Genetic Diagnostic Testing for Inherited Eye Diseases is Highly Accurate and Reproducible and More Sensitive for Variant Detection Than Exome Sequencing

    PubMed Central

    Bujakowska, Kinga M.; Sousa, Maria E.; Fonseca-Kelly, Zoë D.; Taub, Daniel G.; Janessian, Maria; Wang, Dan Yi; Au, Elizabeth D.; Sims, Katherine B.; Sweetser, David A.; Fulton, Anne B.; Liu, Qin; Wiggs, Janey L.; Gai, Xiaowu; Pierce, Eric A.

    2015-01-01

    Purpose Next-generation sequencing (NGS) based methods are being adopted broadly for genetic diagnostic testing, but the performance characteristics of these techniques have not been fully defined with regard to test accuracy and reproducibility. Methods We developed a targeted enrichment and NGS approach for genetic diagnostic testing of patients with inherited eye disorders, including inherited retinal degenerations, optic atrophy and glaucoma. In preparation for providing this Genetic Eye Disease (GEDi) test on a CLIA-certified basis, we performed experiments to measure the sensitivity, specificity, reproducibility as well as the clinical sensitivity of the test. Results The GEDi test is highly reproducible and accurate, with sensitivity and specificity for single nucleotide variant detection of 97.9% and 100%, respectively. The sensitivity for variant detection was notably better than the 88.3% achieved by whole exome sequencing (WES) using the same metrics, due to better coverage of targeted genes in the GEDi test compared to commercially available exome capture sets. Prospective testing of 192 patients with IRDs indicated that the clinical sensitivity of the GEDi test is high, with a diagnostic rate of 51%. Conclusion The data suggest that based on quantified performance metrics, selective targeted enrichment is preferable to WES for genetic diagnostic testing. PMID:25412400

  10. Generating and Describing Affective Eye Behaviors

    NASA Astrophysics Data System (ADS)

    Mao, Xia; Li, Zheng

    The manner of a person's eye movement conveys much about nonverbal information and emotional intent beyond speech. This paper describes work on expressing emotion through eye behaviors in virtual agents based on the parameters selected from the AU-Coded facial expression database and real-time eye movement data (pupil size, blink rate and saccade). A rule-based approach to generate primary (joyful, sad, angry, afraid, disgusted and surprise) and intermediate emotions (emotions that can be represented as the mixture of two primary emotions) utilized the MPEG4 FAPs (facial animation parameters) is introduced. Meanwhile, based on our research, a scripting tool, named EEMML (Emotional Eye Movement Markup Language) that enables authors to describe and generate emotional eye movement of virtual agents, is proposed.

  11. Lowered threshold energy for femtosecond laser induced optical breakdown in a water based eye model by aberration correction with adaptive optics.

    PubMed

    Hansen, Anja; Géneaux, Romain; Günther, Axel; Krüger, Alexander; Ripken, Tammo

    2013-06-01

    In femtosecond laser ophthalmic surgery tissue dissection is achieved by photodisruption based on laser induced optical breakdown. In order to minimize collateral damage to the eye laser surgery systems should be optimized towards the lowest possible energy threshold for photodisruption. However, optical aberrations of the eye and the laser system distort the irradiance distribution from an ideal profile which causes a rise in breakdown threshold energy even if great care is taken to minimize the aberrations of the system during design and alignment. In this study we used a water chamber with an achromatic focusing lens and a scattering sample as eye model and determined breakdown threshold in single pulse plasma transmission loss measurements. Due to aberrations, the precise lower limit for breakdown threshold irradiance in water is still unknown. Here we show that the threshold energy can be substantially reduced when using adaptive optics to improve the irradiance distribution by spatial beam shaping. We found that for initial aberrations with a root-mean-square wave front error of only one third of the wavelength the threshold energy can still be reduced by a factor of three if the aberrations are corrected to the diffraction limit by adaptive optics. The transmitted pulse energy is reduced by 17% at twice the threshold. Furthermore, the gas bubble motions after breakdown for pulse trains at 5 kilohertz repetition rate show a more transverse direction in the corrected case compared to the more spherical distribution without correction. Our results demonstrate how both applied and transmitted pulse energy could be reduced during ophthalmic surgery when correcting for aberrations. As a consequence, the risk of retinal damage by transmitted energy and the extent of collateral damage to the focal volume could be minimized accordingly when using adaptive optics in fs-laser surgery.

  12. Lowered threshold energy for femtosecond laser induced optical breakdown in a water based eye model by aberration correction with adaptive optics.

    PubMed

    Hansen, Anja; Géneaux, Romain; Günther, Axel; Krüger, Alexander; Ripken, Tammo

    2013-06-01

    In femtosecond laser ophthalmic surgery tissue dissection is achieved by photodisruption based on laser induced optical breakdown. In order to minimize collateral damage to the eye laser surgery systems should be optimized towards the lowest possible energy threshold for photodisruption. However, optical aberrations of the eye and the laser system distort the irradiance distribution from an ideal profile which causes a rise in breakdown threshold energy even if great care is taken to minimize the aberrations of the system during design and alignment. In this study we used a water chamber with an achromatic focusing lens and a scattering sample as eye model and determined breakdown threshold in single pulse plasma transmission loss measurements. Due to aberrations, the precise lower limit for breakdown threshold irradiance in water is still unknown. Here we show that the threshold energy can be substantially reduced when using adaptive optics to improve the irradiance distribution by spatial beam shaping. We found that for initial aberrations with a root-mean-square wave front error of only one third of the wavelength the threshold energy can still be reduced by a factor of three if the aberrations are corrected to the diffraction limit by adaptive optics. The transmitted pulse energy is reduced by 17% at twice the threshold. Furthermore, the gas bubble motions after breakdown for pulse trains at 5 kilohertz repetition rate show a more transverse direction in the corrected case compared to the more spherical distribution without correction. Our results demonstrate how both applied and transmitted pulse energy could be reduced during ophthalmic surgery when correcting for aberrations. As a consequence, the risk of retinal damage by transmitted energy and the extent of collateral damage to the focal volume could be minimized accordingly when using adaptive optics in fs-laser surgery. PMID:23761849

  13. Lowered threshold energy for femtosecond laser induced optical breakdown in a water based eye model by aberration correction with adaptive optics

    PubMed Central

    Hansen, Anja; Géneaux, Romain; Günther, Axel; Krüger, Alexander; Ripken, Tammo

    2013-01-01

    In femtosecond laser ophthalmic surgery tissue dissection is achieved by photodisruption based on laser induced optical breakdown. In order to minimize collateral damage to the eye laser surgery systems should be optimized towards the lowest possible energy threshold for photodisruption. However, optical aberrations of the eye and the laser system distort the irradiance distribution from an ideal profile which causes a rise in breakdown threshold energy even if great care is taken to minimize the aberrations of the system during design and alignment. In this study we used a water chamber with an achromatic focusing lens and a scattering sample as eye model and determined breakdown threshold in single pulse plasma transmission loss measurements. Due to aberrations, the precise lower limit for breakdown threshold irradiance in water is still unknown. Here we show that the threshold energy can be substantially reduced when using adaptive optics to improve the irradiance distribution by spatial beam shaping. We found that for initial aberrations with a root-mean-square wave front error of only one third of the wavelength the threshold energy can still be reduced by a factor of three if the aberrations are corrected to the diffraction limit by adaptive optics. The transmitted pulse energy is reduced by 17% at twice the threshold. Furthermore, the gas bubble motions after breakdown for pulse trains at 5 kilohertz repetition rate show a more transverse direction in the corrected case compared to the more spherical distribution without correction. Our results demonstrate how both applied and transmitted pulse energy could be reduced during ophthalmic surgery when correcting for aberrations. As a consequence, the risk of retinal damage by transmitted energy and the extent of collateral damage to the focal volume could be minimized accordingly when using adaptive optics in fs-laser surgery. PMID:23761849

  14. Infrared eye: an operational prototype

    NASA Astrophysics Data System (ADS)

    Chevrette, Paul C.; Fortin, Jean; St-Germain, Daniel; Delisle, Jean

    1998-09-01

    A new concept of surveillance system called Wide Area Coverage Infrared Surveillance System (WACISS), based on the human vision, was developed and a first laboratory prototype was demonstrated recently. A second prototype, more operational, is named the Infrared Eye is being built and will be tested in cooperation with the NRCC Flight Research Laboratory. The Infrared Eye will use the new pixel-less quantum well infrared photodetector sensors, coupled to light emitting diodes (QWIP/LED), currently being developed at NRCC Institute for Microstructural Science under DREV sponsorship. The multiple advantages of the pixel-less QWIP/LED over conventional sensors will considerably simplify the design of the system. As the WACISS, the IR Eye will integrate two cameras: the first, with a wide field-of- view, will be used for detection while the second camera, with a narrower field with higher resolution for identification, will be mobile within the WFOV and slaved to the operator's line-of-sight by means of an eye-tracking system. The images from both cameras will be fused and shown simultaneously on a standard high resolution CRT display unit, interfaced with the eye-tracking unit. The basic concepts pertaining to the project and the design constraints of this second prototype are presented.

  15. Best practice eye care models

    PubMed Central

    Qureshi, Babar M; Mansur, Rabiu; Al-Rajhi, Abdulaziz; Lansingh, Van; Eckert, Kristen; Hassan, Kunle; Ravilla, Thulasiraj; Muhit, Mohammad; Khanna, Rohit C; Ismat, Chaudhry

    2012-01-01

    Since the launching of Global Initiative, VISION 2020 “the Right to Sight” many innovative, practical and unique comprehensive eye care services provision models have evolved targeting the underserved populations in different parts of the World. At places the rapid assessment of the burden of eye diseases in confined areas or utilizing the key informants for identification of eye diseases in the communities are promoted for better planning and evidence based advocacy for getting / allocation of resources for eye care. Similarly for detection and management of diabetes related blindness, retinopathy of prematurity and avoidable blindness at primary level, the major obstacles are confronted in reaching to them in a cost effective manner and then management of the identified patients accordingly. In this regard, the concept of tele-ophthalmology model sounds to be the best solution. Whereas other models on comprehensive eye care services provision have been emphasizing on surgical output through innovative scales of economy that generate income for the program and ensure its sustainability, while guaranteeing treatment of the poorest of the poor. PMID:22944741

  16. Eye mechanics and their implications for eye movement control

    NASA Astrophysics Data System (ADS)

    Koene, Ansgar Roald

    2002-11-01

    The topic of this thesis is the investigation of the mechanical properties of the oculomotor system and the implications of these properties for eye movement control. The investigation was conducted by means of computer models and simulations. This allowed us to combine data from anatomy, physiology and psychophysics with basic principles of physics (mechanics) and mathematics (geometry). In chapter 2 we investigate the degree to which mechanical and neural non-linearities contribute to the kinematic differences between centrifugal and centripetal saccades. On the basis of the velocity profiles of centrifugal and centripetal saccades we calculate the forces and muscle innervations during these eye movements. This was done using an inverted model of the eye plant. Our results indicate that the non-linear force-velocity relationship (i.e. muscle viscosity) of the muscles is probably the cause of the kinematic differences between centrifugal and centripetal saccades. In chapter 3 we calculate the adjustment of the saccadic command that is necessary to compensate for the eye plant non-linearities. These calculations show that the agonist and antagonist muscles require different net saccade signal gain changes. In order to better understand how this gain change is accomplished we use the inverted model of the eye plant (chapter 2) to calculate the muscle innervation profiles of saccades with different starting orientations. Based on these calculations we conclude that the saccade signal gain changes are accomplished primarily by changes in the magnitude of the saccade signal. In chapter 4 we examine the requirements that the oculomotor system must meet for the eye to be able to make desired gaze changes and fixate at various eye orientations. We first determine how the axes of action (i.e. unit moment vectors) of the muscles are related to eye orientation and the location of the effective muscle origin (i.e. the muscle pulleys). Next we show how this relation constrains

  17. One-step detection of pathogens and cancer biomarkers by the naked eye based on aggregation of immunomagnetic beads

    NASA Astrophysics Data System (ADS)

    Chen, Yiping; Xianyu, Yunlei; Sun, Jiashu; Niu, Yajing; Wang, Yu; Jiang, Xingyu

    2015-12-01

    This report shows that immunomagnetic beads (IMBs) can act as the optical readout for assays, in addition to serving as the carrier for purification/separation. Under the influence of an external magnet, IMBs are attracted to coat one side of a test tube. IMBs specifically bound to targets can form a narrow brown stripe, whereas free IMBs will form a diffuse, yellow coating on the side of the test tube. Target analytes can aggregate initially dispersed IMBs in a sample concentration-dependent manner, yielding a color change from yellow to brown that can be seen with the naked eye. This assay combines the convenience of a lateral flow assay, allowing a one-step assay to finish within 15 min, with the sensitivity of an enzyme-linked immonosorbent assay.This report shows that immunomagnetic beads (IMBs) can act as the optical readout for assays, in addition to serving as the carrier for purification/separation. Under the influence of an external magnet, IMBs are attracted to coat one side of a test tube. IMBs specifically bound to targets can form a narrow brown stripe, whereas free IMBs will form a diffuse, yellow coating on the side of the test tube. Target analytes can aggregate initially dispersed IMBs in a sample concentration-dependent manner, yielding a color change from yellow to brown that can be seen with the naked eye. This assay combines the convenience of a lateral flow assay, allowing a one-step assay to finish within 15 min, with the sensitivity of an enzyme-linked immonosorbent assay. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr07044a

  18. Occupational exposure to the whole body, extremities and to the eye lens in interventional radiology in Poland, as based on personnel dosimetry records at IFJ PAN

    NASA Astrophysics Data System (ADS)

    Szumska, Agnieszka; Budzanowski, M.; Kopeć, R.

    2014-11-01

    We report results of measurements of Hp(10) from whole body dosimeters (about 53 thousand readouts), of Hp(0.07) from finger ring dosimeters (23 thousand readouts) and of Hp(3) from eye lens dosimeters (100 readouts), issued in the years 2010-12 to over 150 medical departments in Poland which apply X-rays in radiology, interventional radiology (haemodynamic, angiology, cardiac surgery), urology, orthopaedics, electrophysiology or electro-cardiology. In all measurements thermoluminescence detectors (TLD) were used: the well-known standard MTS-N (LiF:Mg, Ti) for whole body and extremity dosimetry, and the high-sensitivity MCP-N (LiF:Mg, Cu, P) for eye lens dosimetry and environmental monitoring. We analysed the data base of the accredited Laboratory of Individual and Environmental Dosimetry (LADIS) at the Institute of Nuclear Physics PAN which offers its dosimetry service to these departments on a regular basis. We found that in the population of radiation workers that studied over the years 2010-2012 in 84%, 87%, and 34% of Hp(10), Hp(0.07) and Hp(3) measurements, respectively, the level of 0.1 mSv/quarter did not exceed, indicating lack of their occupational exposure. In the remaining 16%, 13% and 66% of individual cases, the 0.1 mSv/quarter exceeded, occasionally reaching several hundreds of mSv/quarter.

  19. On the comparison of visual discomfort generated by S3D and 2D content based on eye-tracking features

    NASA Astrophysics Data System (ADS)

    Iatsun, Iana; Larabi, Mohamed-Chaker; Fernandez-Maloigne, Christine

    2014-03-01

    The changing of TV systems from 2D to 3D mode is the next expected step in the telecommunication world. Some works have already been done to perform this progress technically, but interaction of the third dimension with humans is not yet clear. Previously, it was found that any increased load of visual system can create visual fatigue, like prolonged TV watching, computer work or video gaming. But watching S3D can cause another nature of visual fatigue, since all S3D technologies creates illusion of the third dimension based on characteristics of binocular vision. In this work we propose to evaluate and compare the visual fatigue from watching 2D and S3D content. This work shows the difference in accumulation of visual fatigue and its assessment for two types of content. In order to perform this comparison eye-tracking experiments using six commercially available movies were conducted. Healthy naive participants took part into the test and gave their answers feeling the subjective evaluation. It was found that watching stereo 3D content induce stronger feeling of visual fatigue than conventional 2D, and the nature of video has an important effect on its increase. Visual characteristics obtained by using eye-tracking were investigated regarding their relation with visual fatigue.

  20. Eye injuries in childhood.

    PubMed

    Grin, T R; Nelson, L B; Jeffers, J B

    1987-07-01

    A 3-year survey was conducted of all children with eye injuries admitted to Wills Eye Hospital to determine demographic, etiologic, and prophylactic factors. There were 278 cases, representing 22% of all ocular injuries in children requiring admission. The frequency of childhood ocular injuries is high, often resulting in serious visual impairment. Many of these injuries are preventable. The causes of pediatric eye injuries and preventive measures are discussed.

  1. The Role of Biological Agents and Immunomodulators in Treatment Strategies for Thyroid Eye Disease: An Evidence-based Review.

    PubMed

    Ginter, Anna; Migliori, Michael E

    2016-06-01

    Graves' Disease is an autoimmune disease where circulating antibodies bind to the thyrotropin receptors on the thyroid gland. These bound antibodies mimic thyroid stimulating hormone without the normal feedback from the anterior pituitary, causing hyperthyroidism and thyrotoxicosis. These antibodies also interact with orbital tissues and cause the characteristic orbital findings of thyroid eye disease (TED). It is not clearly understood why anatomically and physiologically distinct tissues like the thyroid gland and orbit are affected selectively, or why the orbital disease tends to be self-limited. Identifying and understanding these processes is critical to targeting therapy. In the active phase of the disease patients may experience orbital inflammation, eyelid and conjunctiva edema (chemosis), eyelid retraction, proptosis, ocular motility restriction, and optic nerve compression. Current treatment strategies for the ocular symptoms have been predominantly directed at symptomatic relief. More recently, investigators have concentrated their efforts to better understanding the underlying pathophysiologic processes to direct therapy at these processes. This review examines the current literature exploring a variety of newer therapeutic alternatives, including immunomodulative and suppressive agents, targeted at strategic points of the active-phase TED pathophysiological pathways. Specifically, biological agents including rituximab, adalimumab, intravenous immunoglobulin and others are reviewed with considerations for pathophysiology, extent of literature support, and adverse effects. [Full article available at http://rimed.org/rimedicaljournal-2016-06.asp, free with no login].

  2. Dry eye disease and depression-anxiety-stress: A hospital-based case control study in Turkey

    PubMed Central

    Yilmaz, Ugur; Gokler, Mehmet Enes; Unsal, Alaettin

    2015-01-01

    Objective: The aim of the present study was to investigate the association between dry eye disease (DED) and psychosomatic conditions, such as depression, stress, and anxiety, and the distribution of associated risk factors. Methods: In this case control study, the sample consisted of 121 DED subjects and 242 control subjects. Each subjects was diagnosed as having DED or not by an ophthalmologist. Ocular Surface Disease Index and Depression Anxiety Stress Scales were administered to all subjects. Data were analysed using chi-square and Mann Whitney U tests as a univariate analysis and multiple logistic regression as a multivariate analysis. Results: Of 1,458 consecutive outpatients, clinically diagnosed DED was present in 121 individuals (8.3%). There was a significant relationship of family history of DED (OR, 1.43; 95% CI, 0.84-2.41), chronic disease history (OR, 2.84; 95% CI, 1.66-4.87), OSDI score (OR, 1.07; 95% CI, 1.97–4.06), depression (OR, 2.06; 95% CI, 1.30-3.27), anxiety (OR, 2.66; 95% CI, 1.67-4.23), and stress (OR, 2.33; 95% CI, 1.48-3.67) with DED. Conclusion: Individuals with depression, anxiety and stress are more likely to experience DED. In addition to confirming some well-known risk factors, this study has found new associations between DED and a family history of DED and the presence of stress. PMID:26150857

  3. LASIK and dry eye.

    PubMed

    Toda, Ikuko

    2007-01-01

    Dry eye is one of the most common complications after laser-assisted in situ keratomileusis (LASIK). The clinical signs of post-LASIK dry eye include positive vital staining of ocular surface, decreased tear film breakup time and Schirmer test, reduced corneal sensitivity, and decreased functional visual acuity. The symptoms and signs last at least 1 month after LASIK. Although the mechanisms for developing post-LASIK dry eye are not completely understood, loss of corneal innervation by flap-making may affect the reflex loops of the corneal-lacrimal gland, corneal-blinking, and blinking-meibomian gland, and blinking-meibomian gland, resulting in decreased aqueous and lipid tear secretion and mucin expression. As LASIK enhancement by flap-lifting induces less dry eye symptoms and signs than first surgery, it is suggested that other factors rather than loss of neurotrophic effect may be involved in the mechanisms of post-LASIK dry eye. The treatments of dry eye include artificial tears, topical cyclosporine, hot compress, punctal plugs, and autologous serum eye drops. For patients with severe preoperative dry eye, a combination of punctal plugs and serum eye drops is required to be used before surgery.

  4. New instruments for dry eye diagnosis.

    PubMed

    Yokoi, Norihiko; Komuro, Aoi; Maruyama, Kunio; Kinoshita, Shigeru

    2005-01-01

    Several non-invasive techniques for dry eye diagnosis have been developed in the past decade. These include quantitative assessment of tear volume, tear film stability, tear dynamics, and integrity of ocular surface epithelium. A combination of meniscometry and interferometry is useful for proving focal dry eye, by confirming whether or not tears at the meniscus have an effect on the ocular surface. Interferometer is also useful to evaluate tear dynamics on soft contact lenses. Fluorophotometry is useful for assessing the severity of dry eye from the view point of corneal epithelial barrier function and measuring the tear turnover rate. Both video-meibography and meibometry are useful for screening meibomian gland dysfunction. The advances in these techniques accumulate knowledge regarding pathophysiology of dry eye and allow precise diagnosis of dry eye. More targeted treatment will become feasible based on the clearer pathophysiology.

  5. Multiscale systems integration in the eye.

    PubMed

    Jacobs, Marc D

    2009-01-01

    A series of research topics on the eye is reviewed with the aim of illustrating how integrative and systems-biological approaches can be used to understand complex properties and functions of ocular tissues. Emphasis is placed on the diversity of physiological systems represented in the eye, and the variety of approaches required to analyze those systems, both empirically and theoretically. Modeling and empirical studies reviewed focus mainly on problems that the eye presents, in the broad areas of biomechanics and fluid dynamics from the molecular to the whole-organ scale. Attention is given to the relevance of these studies in human disease and the current potential for development of medical therapies based upon a biophysical, integrative modeling approach. The creation of a multiscale hierarchy of numerical models of the eye is proposed as an important and unifying aim of integrative eye research.

  6. Rapid hybridization of chitosan-gold-antibodies via metal-free click in water-based systems: a model approach for naked-eye detectable antigen sensors.

    PubMed

    Jirawutthiwongchai, Jatesuda; Draeger, Gerald; Chirachanchai, Suwabun

    2014-07-01

    A surface plasmon resonance (SPR) expression after hybridization of chitosan-gold nanoparticle-antibody (CS-AuNPs-Ab) based on: i) metal-free click chemistry, and, ii) in water system as an approach for a rapid antigen sensing, is proposed. The chitosan-hydroxybenzyl triazole complex enables us to carry out the conjugation of mPEG and trifluoromethylated oxanorbornadiene (OND) in water. CS-mPEG-OND further allows metal-free click to hybridize chitosan (CS) with azido-modified gold nanoparticles (azido-AuNPs) in aqueous solution at room temperature. The CS-mPEG-OND conjugated with LipL32 antibody (Ab) not only effectively binds with LipL32 antigen (Ag) but also performs the cycloaddition with azido-AuNPs to display a change in color within 2 min. The phenomenon leads to a simple and efficient naked-eye antigen detection technique.

  7. Paper-based fluorescent sensor for rapid naked-eye detection of acetylcholinesterase activity and organophosphorus pesticides with high sensitivity and selectivity.

    PubMed

    Chang, Jiafu; Li, Haiyin; Hou, Ting; Li, Feng

    2016-12-15

    Various strategies have been proposed for the sensing of acetylcholinesterase (AChE) activity and organophosphorus pesticides (OPs). However, the practical application of most methods is restricted by their intrinsic drawbacks such as complexity, long analysis time, and high cost. Thus, it is highly desirable to develop simple, fast and sensitive approaches for AChE activity and OPs detection. Herein, we reported a simple paper-based fluorescent sensor (PFS) based on the aggregation induced emission (AIE) effect of tetraphenylethylene (TPE) and the addition reaction capability of maleimide, which has been used as a powerful tool for rapid naked-eye detection of AChE activity and OPs. The introduction of TPE provides the probe with unique fluorescence property in solid state and is of great importance for improving the sensitivity of PFS. The hydrolysis product of acetylthiocholine catalyzed by AChE induced the maleimide ring destruction and activated the fluorescence performance of TPE. Given that AChE activity can be specifically inhibited by OPs, the as-proposed PFS can also be utilized for sensitive detection of OPs. Meanwhile, the variation of fluorescence signal can be readily detected by naked eyes, and low detection limits of 2.5mUmL(-1) and 0.5ngmL(-1) for AChE activity and OPs are obtained, respectively. Moreover, it has been successfully applied for AChE activity and OPs detection in diluted human serum samples, showing its great potential to be applied in real samples. Thus, this strategy possesses considerable advantages of simplicity, rapid detection, portability, cost efficiency and visualization. PMID:27498323

  8. Paper-based fluorescent sensor for rapid naked-eye detection of acetylcholinesterase activity and organophosphorus pesticides with high sensitivity and selectivity.

    PubMed

    Chang, Jiafu; Li, Haiyin; Hou, Ting; Li, Feng

    2016-12-15

    Various strategies have been proposed for the sensing of acetylcholinesterase (AChE) activity and organophosphorus pesticides (OPs). However, the practical application of most methods is restricted by their intrinsic drawbacks such as complexity, long analysis time, and high cost. Thus, it is highly desirable to develop simple, fast and sensitive approaches for AChE activity and OPs detection. Herein, we reported a simple paper-based fluorescent sensor (PFS) based on the aggregation induced emission (AIE) effect of tetraphenylethylene (TPE) and the addition reaction capability of maleimide, which has been used as a powerful tool for rapid naked-eye detection of AChE activity and OPs. The introduction of TPE provides the probe with unique fluorescence property in solid state and is of great importance for improving the sensitivity of PFS. The hydrolysis product of acetylthiocholine catalyzed by AChE induced the maleimide ring destruction and activated the fluorescence performance of TPE. Given that AChE activity can be specifically inhibited by OPs, the as-proposed PFS can also be utilized for sensitive detection of OPs. Meanwhile, the variation of fluorescence signal can be readily detected by naked eyes, and low detection limits of 2.5mUmL(-1) and 0.5ngmL(-1) for AChE activity and OPs are obtained, respectively. Moreover, it has been successfully applied for AChE activity and OPs detection in diluted human serum samples, showing its great potential to be applied in real samples. Thus, this strategy possesses considerable advantages of simplicity, rapid detection, portability, cost efficiency and visualization.

  9. Bio-inspired hemispherical compound eye camera

    NASA Astrophysics Data System (ADS)

    Xiao, Jianliang; Song, Young Min; Xie, Yizhu; Malyarchuk, Viktor; Jung, Inhwa; Choi, Ki-Joong; Liu, Zhuangjian; Park, Hyunsung; Lu, Chaofeng; Kim, Rak-Hwan; Li, Rui; Crozier, Kenneth B.; Huang, Yonggang; Rogers, John A.

    2014-03-01

    Compound eyes in arthropods demonstrate distinct imaging characteristics from human eyes, with wide angle field of view, low aberrations, high acuity to motion and infinite depth of field. Artificial imaging systems with similar geometries and properties are of great interest for many applications. However, the challenges in building such systems with hemispherical, compound apposition layouts cannot be met through established planar sensor technologies and conventional optics. We present our recent progress in combining optics, materials, mechanics and integration schemes to build fully functional artificial compound eye cameras. Nearly full hemispherical shapes (about 160 degrees) with densely packed artificial ommatidia were realized. The number of ommatidia (180) is comparable to those of the eyes of fire ants and bark beetles. The devices combine elastomeric compound optical elements with deformable arrays of thin silicon photodetectors, which were fabricated in the planar geometries and then integrated and elastically transformed to hemispherical shapes. Imaging results and quantitative ray-tracing-based simulations illustrate key features of operation. These general strategies seem to be applicable to other compound eye devices, such as those inspired by moths and lacewings (refracting superposition eyes), lobster and shrimp (reflecting superposition eyes), and houseflies (neural superposition eyes).

  10. Benefits of Red-Edge Spectral Band and Texture Features for the Object-based Classification using RapidEye sSatellite Image data

    NASA Astrophysics Data System (ADS)

    Kim, H. O.; Yeom, J. M.

    2014-12-01

    Space-based remote sensing in agriculture is particularly relevant to issues such as global climate change, food security, and precision agriculture. Recent satellite missions have opened up new perspectives by offering high spatial resolution, various spectral properties, and fast revisit rates to the same regions. Here, we examine the utility of broadband red-edge spectral information in multispectral satellite image data for classifying paddy rice crops in South Korea. Additionally, we examine how object-based spectral features affect the classification of paddy rice growth stages. For the analysis, two seasons of RapidEye satellite image data were used. The results showed that the broadband red-edge information slightly improved the classification accuracy of the crop condition in heterogeneous paddy rice crop environments, particularly when single-season image data were used. This positive effect appeared to be offset by the multi-temporal image data. Additional texture information brought only a minor improvement or a slight decline, although it is well known to be advantageous for object-based classification in general. We conclude that broadband red-edge information derived from conventional multispectral satellite data has the potential to improve space-based crop monitoring. Because the positive or negative effects of texture features for object-based crop classification could barely be interpreted, the relationships between the textual properties and paddy rice crop parameters at the field scale should be further examined in depth.

  11. An Eye for Learning.

    ERIC Educational Resources Information Center

    Ostwald, Thomas

    1995-01-01

    Presents a hands-on activity as an excellent starting point for investigations related to the eye. Involves making a simple model of the vertebrate eye to illustrate the formation of an upside-down image on the retina by the lens. Links to investigations in numerous science disciplines including astronomy, genetics, biology, earth science, and…

  12. Photorefraction of the Eye

    ERIC Educational Resources Information Center

    Colicchia, Giuseppe; Wiesner, Hartmut; Zollman, Dean

    2015-01-01

    Photorefraction is a method to easily estimate the refractive state of the eye. The principle of photorefraction involves projecting light into the eye during flash photography and then examining the paths of light that emerge from the pupil after scattering on the back portion of the interior of the eyeball (fundus). We will explain the optical…

  13. Eye tissues study

    NASA Astrophysics Data System (ADS)

    Tuchin, Valery V.; Bashkatov, Alexey N.; Maksimova, Irina L.; Sinichkin, Yurii P.; Simonenko, Georgy V.; Genina, Elina A.; Lakodina, Nina A.

    2001-08-01

    Theoretical and in vitro and in vivo experimental study of spectral and polarization characteristics of the human and rabbit eye tissues are presented. The possibility of control of optical properties of eye cornea, lens and sclera is discussed and realized experimentally for glucose solution as the refractive index matching factor.

  14. Preventing Eye Injuries

    MedlinePlus

    ... Eye Injuries Reviewed by: Brenda Pagan-Duran MD Mar. 01, 2016 Protecting your eyes from injury is one of the most basic things you can do to keep your vision healthy throughout your life. You may be somewhat aware of the possible ...

  15. Smoking and Eye Health

    MedlinePlus

    ... Eye Health Apr. 14, 2014 Avoiding smoking and second hand smoke — or quitting if you are a smoker — are ... influence your eyes’ health. And tobacco smoke, including second-hand smoke, is an irritant that worsens dry eye , a ...

  16. Understanding pink eye

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Pink eye (PE) is a physiological tuber disorder that can result in serious processing complications and storage losses. The earliest external symptoms consist of an ephemeral pinkish discoloration around tuber eyes, predominately at the bud end of the tuber. These pinkish areas can then develop into...

  17. Return sweep latency in reading with a paralyzed eye.

    PubMed

    Leisman, G

    1977-06-01

    The study concerned the distribution of directional control of eye movement in reading. With the paralysis of the right eye, progressive movements of the left eye were possible, but regressive movements were cancelled, being observed as drift. Base-out prism placed over the non-paralyzed eye allowed for the re-establishment of regressive movements. The results for this subject were explained on the basis of a large retinal error marker having been established. With the paralysis of one eye, base-out prisms reduce that error.

  18. Eye burning - itching and discharge

    MedlinePlus

    ... allergies or hay fever Infections, bacterial or viral ( conjunctivitis or pink eye) Chemical irritants (such as chlorine ... to help with allergies. Pink eye or viral conjunctivitis causes a red or bloodshot eye and excessive ...

  19. Advocacy for eye care

    PubMed Central

    Ravilla, Thulasiraj D; Ramasamy, Dhivya

    2012-01-01

    The effectiveness of eye care service delivery is often dependant on how the different stakeholders are aligned. These stakeholders range from the ministries of health who have the capacity to grant government subsidies for eye care, down to the primary healthcare workers who can be enrolled to screen for basic eye diseases. Advocacy is a tool that can help service providers draw the attention of key stakeholders to a particular area of concern. By enlisting the support, endorsement and participation of a wider circle of players, advocacy can help to improve the penetration and effectiveness of the services provided. There are several factors in the external environmental that influence the eye care services – such as the availability of trained manpower, supply of eye care consumables, government rules and regulations. There are several instances where successful advocacy has helped to create an enabling environment for eye care service delivery. Providing eye care services in developing countries requires the support – either for direct patient care or for support services such as producing trained manpower or for research and dissemination. Such support, in the form of financial or other resources, can be garnered through advocacy. PMID:22944745

  20. Estimating peak skin and eye lens dose from neuroperfusion examinations: Use of Monte Carlo based simulations and comparisons to CTDIvol, AAPM Report No. 111, and ImPACT dosimetry tool values

    PubMed Central

    Zhang, Di; Cagnon, Chris H.; Villablanca, J. Pablo; McCollough, Cynthia H.; Cody, Dianna D.; Zankl, Maria; Demarco, John J.; McNitt-Gray, Michael F.

    2013-01-01

    Purpose: CT neuroperfusion examinations are capable of delivering high radiation dose to the skin or lens of the eyes of a patient and can possibly cause deterministic radiation injury. The purpose of this study is to: (a) estimate peak skin dose and eye lens dose from CT neuroperfusion examinations based on several voxelized adult patient models of different head size and (b) investigate how well those doses can be approximated by some commonly used CT dose metrics or tools, such as CTDIvol, American Association of Physicists in Medicine (AAPM) Report No. 111 style peak dose measurements, and the ImPACT organ dose calculator spreadsheet. Methods: Monte Carlo simulation methods were used to estimate peak skin and eye lens dose on voxelized patient models, including GSF's Irene, Frank, Donna, and Golem, on four scanners from the major manufacturers at the widest collimation under all available tube potentials. Doses were reported on a per 100 mAs basis. CTDIvol measurements for a 16 cm CTDI phantom, AAPM Report No. 111 style peak dose measurements, and ImPACT calculations were performed for available scanners at all tube potentials. These were then compared with results from Monte Carlo simulations. Results: The dose variations across the different voxelized patient models were small. Dependent on the tube potential and scanner and patient model, CTDIvol values overestimated peak skin dose by 26%–65%, and overestimated eye lens dose by 33%–106%, when compared to Monte Carlo simulations. AAPM Report No. 111 style measurements were much closer to peak skin estimates ranging from a 14% underestimate to a 33% overestimate, and with eye lens dose estimates ranging from a 9% underestimate to a 66% overestimate. The ImPACT spreadsheet overestimated eye lens dose by 2%–82% relative to voxelized model simulations. Conclusions: CTDIvol consistently overestimates dose to eye lens and skin. The ImPACT tool also overestimated dose to eye lenses. As such they are still

  1. Object-Based Visual Attention in 8-Month-Old Infants: Evidence from an Eye-Tracking Study

    ERIC Educational Resources Information Center

    Bulf, Hermann; Valenza, Eloisa

    2013-01-01

    Visual attention is one of the infant's primary tools for gathering relevant information from the environment for further processing and learning. The space-based component of visual attention in infants has been widely investigated; however, the object-based component of visual attention has received scarce interest. This scarcity is…

  2. Eye-Safe Lidar

    NASA Technical Reports Server (NTRS)

    Byer, Robert L.

    1989-01-01

    Laser infrared radar (lidar) undergoing development harmless to human eyes, consists almost entirely of solid-state components, and offers high range resolution. Operates at wavelength of about 2 micrometers. If radiation from such device strikes eye, almost completely absorbed by cornea without causing damage, even if aimed directly at eye. Continuous-wave light from laser oscillator amplified and modulated for transmission from telescope. Small portion of output of oscillator fed to single-mode fiber coupler, where mixed with return pulses. Intended for remote Doppler measurements of winds and differential-absorption measurements of concentrations of gases in atmosphere.

  3. Eye-wall resection.

    PubMed Central

    Char, D H; Miller, T; Crawford, J B

    2000-01-01

    PURPOSE: To review the ocular retention rates, visual results, and metastases in uveal tumors managed with eye-wall resection techniques. METHODS: This was a retrospective analysis of uveal tumors selected for eye-wall resection with the surgical procedures performed by a single surgeon. All enucleation specimens were reviewed by one author. Both parametric and non-parametric analysis of data was performed. RESULTS: A total of 132 eyes were scheduled for eye-wall resection surgery. Mean patient age was 52 years (range, 11 to 86 years). Tumors involved the iris alone in 17 cases, the iris-ciliary body in 53, the ciliary body alone in 16, and the choroid (ciliochoroidal, iris-ciliary body-choroid, or choroid) in 46 cases. A total of 114 eyes harbored melanomas; tumors located more posteriorly were more likely to have epithelioid cells (P < .05). Mean follow-up was 6 years. Mean number of clock hours in iris and iris-ciliary body tumors was 3.5. In tumors that involved the choroid, the mean largest diameter was 12.6 mm and the mean thickness was 8.2 mm. Ninety-three (70%) of 132 eyes were retained. Histologic assessment of surgical margins did not correlate with either evidence of tumor in enucleated eyes or metastatic disease. Surgical margins of tumors located more anteriorly were more likely to be clear on histologic evaluation (P < .05). Approximately 56% of retained eyes had a final visual acuity of 20/40 or better; visual results were significantly better in tumors located more anteriorly (P < .05). All retained eyes with iris tumors had a final visual acuity of 20/40 or better. In tumors that involved the choroid, 8 of 25 retained eyes kept visual acuity of 20/40 or better. Metastases developed in 8 patients; all metastatic events developed in patients with tumors that involved the choroid, and 7 of 8 were mixed cell melanomas. CONCLUSIONS: Seventy percent of eyes were retained, and 56% of these had a final visual acuity of 20/40 or better. Only 7% of patients

  4. Modelling human eye under blast loading.

    PubMed

    Esposito, L; Clemente, C; Bonora, N; Rossi, T

    2015-01-01

    Primary blast injury (PBI) is the general term that refers to injuries resulting from the mere interaction of a blast wave with the body. Although few instances of primary ocular blast injury, without a concomitant secondary blast injury from debris, are documented, some experimental studies demonstrate its occurrence. In order to investigate PBI to the eye, a finite element model of the human eye using simple constitutive models was developed. The material parameters were calibrated by a multi-objective optimisation performed on available eye impact test data. The behaviour of the human eye and the dynamics of mechanisms occurring under PBI loading conditions were modelled. For the generation of the blast waves, different combinations of explosive (trinitrotoluene) mass charge and distance from the eye were analysed. An interpretation of the resulting pressure, based on the propagation and reflection of the waves inside the eye bulb and orbit, is proposed. The peculiar geometry of the bony orbit (similar to a frustum cone) can induce a resonance cavity effect and generate a pressure standing wave potentially hurtful for eye tissues.

  5. How to perform irrigation of the eye.

    PubMed

    Marsden, Janet

    2016-02-01

    rationale and key points: This article aims to help nurses to understand the importance of performing irrigation immediately following chemical injury to the eye, and outlines the most effective technique. It is essential that irrigation of the eye is understood and performed correctly. Chemical injury to the eye is an ophthalmic emergency. It presents a serious risk to the patient's vision and may cause blindness. The length of time the chemical remains in contact with the eye determines the severity of the injury. Immediate irrigation of the eye is essential to minimise preventable loss of vision. REFLECTIVE ACTIVITY: Clinical skills articles can help update your practice and ensure it remains evidence based. Apply this article to your practice. Reflect on and write a short account of: 1. How you would ensure immediate irrigation following chemical injury to the eye in your clinical area. 2. How you know when you have irrigated the eye for long enough, if you have previously performed this procedure, and how reading this article might influence your practice. Subscribers can upload their reflective accounts at: rcni.com/portfolio . PMID:26838655

  6. Modelling human eye under blast loading.

    PubMed

    Esposito, L; Clemente, C; Bonora, N; Rossi, T

    2015-01-01

    Primary blast injury (PBI) is the general term that refers to injuries resulting from the mere interaction of a blast wave with the body. Although few instances of primary ocular blast injury, without a concomitant secondary blast injury from debris, are documented, some experimental studies demonstrate its occurrence. In order to investigate PBI to the eye, a finite element model of the human eye using simple constitutive models was developed. The material parameters were calibrated by a multi-objective optimisation performed on available eye impact test data. The behaviour of the human eye and the dynamics of mechanisms occurring under PBI loading conditions were modelled. For the generation of the blast waves, different combinations of explosive (trinitrotoluene) mass charge and distance from the eye were analysed. An interpretation of the resulting pressure, based on the propagation and reflection of the waves inside the eye bulb and orbit, is proposed. The peculiar geometry of the bony orbit (similar to a frustum cone) can induce a resonance cavity effect and generate a pressure standing wave potentially hurtful for eye tissues. PMID:23521031

  7. Binocular coordination of the eyes during reading.

    PubMed

    Liversedge, Simon P; Rayner, Keith; White, Sarah J; Findlay, John M; McSorley, Eugene

    2006-09-01

    Saccadic eye movements and fixations are the behavioral means by which we visually sample text during reading. Human oculomotor control is governed by a complex neurophysiological system involving the brain stem, superior colliculus, and several cortical areas. A very widely held belief among researchers investigating primate vision is that the oculomotor system serves to orient the visual axes of both eyes to fixate the same target point in space. It is argued that such precise positioning of the eyes is necessary to place images on corresponding retinal locations, such that on each fixation a single, nondiplopic, visual representation is perceived. Vision works actively through a continual sampling process involving saccades and fixations. Here we report that during normal reading, the eyes do not always fixate the same letter within a word. We also demonstrate that saccadic targeting is yoked and based on a unified cyclopean percept of a whole word since it is unaffected if different word parts are delivered exclusively to each eye via a dichoptic presentation technique. These two findings together suggest that the visual signal from each eye is fused at a very early stage in the visual pathway, even when the fixation disparity is greater than one character (0.29 deg), and that saccade metrics for each eye are computed on the basis of that fused signal.

  8. LASIK eye surgery

    MedlinePlus

    Laser-Assisted In Situ Keratomileusis; Laser vision correction; Nearsightedness - Lasik; Myopia - Lasik ... For clear vision, the eye's cornea and lens must bend (refract) light rays properly. This allows images to be focused on ...

  9. Anatomy of the Eye

    MedlinePlus

    ... Conditions Frequently Asked Questions Español Condiciones Chinese Conditions Anatomy of the Eye En Español Read in Chinese External (Extraocular) Anatomy Extraocular Muscles: There are six muscles that are ...

  10. Diabetes eye exams

    MedlinePlus

    ... Once you have eye disease caused by diabetes, you need to see an ophthalmologist. ... feel stinging when the drops are first placed. You may have a ... using a bright light. The doctor can then see areas that may ...

  11. Using Eye Makeup

    MedlinePlus

    ... in a moving vehicle. Do not separate your mascara-clumped lashes with sharp items. If you tend ... all eye makeup at night before sleeping, especially mascara that can stick to the lashes. Brush a ...

  12. Amblyopia: Lazy Eye Treatment

    MedlinePlus

    ... Choosing Safe Toys this Holiday Dec 02, 2015 Digital Glasses For Lazy Eye Nov 19, 2015 Follow The Academy Professionals: Education Guidelines News Multimedia Public & Patients: Contact Us About ...

  13. Amblyopia: Lazy Eye Symptoms

    MedlinePlus

    ... Choosing Safe Toys this Holiday Dec 02, 2015 Digital Glasses For Lazy Eye Nov 19, 2015 Follow The Academy Professionals: Education Guidelines News Multimedia Public & Patients: Contact Us About ...

  14. Amblyopia: Lazy Eye Diagnosis

    MedlinePlus

    ... Choosing Safe Toys this Holiday Dec 02, 2015 Digital Glasses For Lazy Eye Nov 19, 2015 Follow The Academy Professionals: Education Guidelines News Multimedia Public & Patients: Contact Us About ...

  15. Fungal Eye Infections

    MedlinePlus

    ... Zoonotic Infectious Disease Division of Foodborne, Waterborne, and Environmental Diseases Mycotic Diseases Branch Fungal Eye Infections Recommend on ... Zoonotic Infectious Disease Division of Foodborne, Waterborne, and Environmental Diseases Mycotic Diseases Branch File Formats Help: How do ...

  16. Dry eye syndrome

    MedlinePlus

    ... particles that have gotten in. A healthy tear film on the eye is necessary for good vision. ... exam Diagnostic staining of the cornea and tear film Measurement of tear film break-up time (TBUT) ...

  17. Eye Injuries in Sports

    MedlinePlus

    ... these injuries can be prevented. Overall, basketball and baseball cause the most eye injuries, followed by water ... involve body contact. Some high-risk sports are baseball, basketball, hockey, football, lacrosse, tennis and other racquet ...

  18. The Perfect Eye A Novel Model for Teaching the Theory of Refraction.

    ERIC Educational Resources Information Center

    Kurtz, Daniel

    1999-01-01

    The Perfect Eye model simplifies solutions to a wide variety of optometry instructional problems by facilitating student understanding of the interaction among lenses, objects, accommodation, and ametropia. The model is based on the premise that inside every eye is a perfect (emmetropic) eye, and that the physiological eye is a combination of the…

  19. Cord blood serum-based eye drops: the impact of donor haematological and obstetric factors on the variability of epidermal growth factor levels

    PubMed Central

    Versura, Piera; Buzzi, Marina; Giannaccare, Giuseppe; Grillini, Marco; Terzi, Adriana; Pagliaro, Pasqualepaolo; Campos, Emilio C.

    2014-01-01

    Background Cord blood serum (CBS)-based eye drops are successfully used in corneal epithelial wound healing and are prepared to supply a known amount of epidermal growth factor (EGF). Product standardisation includes expensive EGF dosage in all cord blood (CB) units. The influence of donor obstetric and haematological characteristics on EGF content was evaluated, to exclude unsuitable CBS and pre-select those CB units able to provide the correct EGF supply for healing corneal wounds. Materials and methods Data were retrospectively collected from 135 donors included in the Emilia Romagna Cord Blood Bank records. Obstetric characteristics, parity and gestational age of the mother, sex, birth weight and Apgar score of the neonate, placental weight, duration of labour and mode of delivery were considered. Haematological characteristics, CD34+ cell number, and total nucleated cell, white blood cell and platelet counts were recorded. EGF content in CB units was estimated by enzyme-linked immunosorbent assay. Statistical evaluation was performed by Mann-Whitney unpaired and Student’s t tests. Correlations between variables were evaluated by using Pearson’s (r) or Spearman’s (ρ) correlation coefficients. Results EGF content was significantly higher in CBS from donors aged <30 years and after vaginal deliveries as compared with scheduled Caesarean sections (1,386±580 vs 1,106±391 pg/mL; P=0.002). EGF content was significantly correlated with duration of labour (r=0.45; P=0.0001), number of CD34+ cells/mL (r=0.3; P=0.002) particularly in vaginal deliveries (r=0.36; P=0.003), mother’s age (−0.25; P=0.005), neonate’s birth weight (r=0.27; P=0.005), and total nucleated cell (r=0.25; P=0.006), white cell (r=0.29; P=0.001) and platelet (r=0.24; P=0.009) counts. No significant correlations were found between EGF content and parity, gestational age, placental weight, neonate’s sex or Apgar scores. Discussion EGF levels are higher in CB units from younger mothers

  20. Flavonoid intake and eye health.

    PubMed

    Milbury, Paul E

    2012-01-01

    In the modern era of evidence-based scientific medicine, there is little recognition of centuries of shaman observational evidence. Yet it is extremely difficult to conduct long duration controlled studies of large populations. The controversy surrounding the issue of flavonoid bioactivity and alleged benefits for eye health is also plagued by natural product industry marketing efforts that rely on small, often poorly designed studies. Ample laboratory evidence exists from in vitro and in vivo studies that provide plausible mechanistic evidence for flavonoid interactions relevant to visual function. Lacking are large randomized double-blind placebo-controlled studies in older subjects who have early signs of vision impairment. These studies could link flavonoid intake and bioavailability to efficacy in prevention of age related vision disorders that develop over decades. Support for clinical trials remains to be found before a full "recommendation" can be made regarding the value of diets high in flavonoids for eye health. PMID:22888841

  1. Menopause and dry eye. A possible relationship.

    PubMed

    Versura, Piera; Campos, Emilio C

    2005-05-01

    The hormonal status and in particular sex steroids play a role in the ocular surface homeostasis and function, during the whole life and in both sexes, accomplished by estrogenic and androgenic receptors located on corneal and conjunctival epithelia and Meibomian gland. The ocular surface is an integrated unit and any dysfunction results in a scarce or unstable preocular tear film which produces dry eye, a chronic inflammatory condition with increasing incidence as people get older but always more frequent among females. In post-menopausal women endocrine changes join the aging effects in the pathogenesis of dry eye, but still it remains controversial whether estrogen or androgen deficiency or their imbalance impair ocular surface function. Another questionable issue concerns the efficacy of hormonal replacement therapy in the amelioration of dry eye symptoms and recovery of tear function, since the scientific literature stands in between a therapeutic or a promoting effect of eye dryness. Therapy of dry eye is usually based upon topical administration of tear substitutes; estrogen or androgen-based eye drops represents a promising innovative treatment based upon important scientific rationale.

  2. Menopause and dry eye. A possible relationship.

    PubMed

    Versura, Piera; Campos, Emilio C

    2005-05-01

    The hormonal status and in particular sex steroids play a role in the ocular surface homeostasis and function, during the whole life and in both sexes, accomplished by estrogenic and androgenic receptors located on corneal and conjunctival epithelia and Meibomian gland. The ocular surface is an integrated unit and any dysfunction results in a scarce or unstable preocular tear film which produces dry eye, a chronic inflammatory condition with increasing incidence as people get older but always more frequent among females. In post-menopausal women endocrine changes join the aging effects in the pathogenesis of dry eye, but still it remains controversial whether estrogen or androgen deficiency or their imbalance impair ocular surface function. Another questionable issue concerns the efficacy of hormonal replacement therapy in the amelioration of dry eye symptoms and recovery of tear function, since the scientific literature stands in between a therapeutic or a promoting effect of eye dryness. Therapy of dry eye is usually based upon topical administration of tear substitutes; estrogen or androgen-based eye drops represents a promising innovative treatment based upon important scientific rationale. PMID:16019376

  3. Eye Tracking Young Children with Autism

    PubMed Central

    Sasson, Noah J.; Elison, Jed T.

    2012-01-01

    The rise of accessible commercial eye-tracking systems has fueled a rapid increase in their use in psychological and psychiatric research. By providing a direct, detailed and objective measure of gaze behavior, eye-tracking has become a valuable tool for examining abnormal perceptual strategies in clinical populations and has been used to identify disorder-specific characteristics1, promote early identification2, and inform treatment3. In particular, investigators of autism spectrum disorders (ASD) have benefited from integrating eye-tracking into their research paradigms4-7. Eye-tracking has largely been used in these studies to reveal mechanisms underlying impaired task performance8 and abnormal brain functioning9, particularly during the processing of social information1,10-11. While older children and adults with ASD comprise the preponderance of research in this area, eye-tracking may be especially useful for studying young children with the disorder as it offers a non-invasive tool for assessing and quantifying early-emerging developmental abnormalities2,12-13. Implementing eye-tracking with young children with ASD, however, is associated with a number of unique challenges, including issues with compliant behavior resulting from specific task demands and disorder-related psychosocial considerations. In this protocol, we detail methodological considerations for optimizing research design, data acquisition and psychometric analysis while eye-tracking young children with ASD. The provided recommendations are also designed to be more broadly applicable for eye-tracking children with other developmental disabilities. By offering guidelines for best practices in these areas based upon lessons derived from our own work, we hope to help other investigators make sound research design and analysis choices while avoiding common pitfalls that can compromise data acquisition while eye-tracking young children with ASD or other developmental difficulties. PMID:22491039

  4. "Kindergarten, can I have your eyes and ears?" politeness and teacher directive choices in inquiry-based science classrooms

    NASA Astrophysics Data System (ADS)

    Oliveira, Alandeom Wanderlei

    2009-12-01

    This study explores elementary teachers' social understandings and employment of directives and politeness while facilitating inquiry science lessons prior and subsequent to their participation in a summer institute in which they were introduced to the scholarly literature on regulative discourse (directives used by teachers to regulate student behavior). A grounded theory analysis of the institute professional development activities revealed that teachers developed an increased awareness of the authoritative functions served by impolite or direct directives (i.e., pragmatic awareness). Furthermore, a comparative microethnographic analysis of participants' inquiry-based classroom practices revealed that after the institute teachers demonstrated an increased ability to share authority with students by strategically making directive choices that were more polite, indirect, inclusive, involvement-focused and creative. Such ability led to a reduced emphasis on teacher regulation of student compliance with classroom behavioral norms and an increased focus on the discursive organization of the inquiry-based science learning/teaching process. Despite teachers' increased pragmatic awareness, teacher-student linguistic relationships did not become entirely symmetrical subsequent to their participation in the summer institute (i.e., teacher authority was not completely relinquished or lost). Based on such findings, it is argued that teachers need to develop higher levels of pragmatic awareness to become effectively prepared to engage in language-mediated teacher-student interaction in the context of inquiry-based science classroom discourse.

  5. Faith-Based Media Literacy Education: A Look at the Past with an Eye toward the Future

    ERIC Educational Resources Information Center

    Iaquinto, Stephanie; Keeler, John

    2012-01-01

    This article addresses several fundamental questions about faith-based media literacy education in the United States, including how the assumptions, motivations, goals, and pedagogy of those Christians who are operating within a media literacy framework come together to create a unique approach to teaching media literacy. After briefly reviewing…

  6. Eye Protection in Educational Institutions.

    ERIC Educational Resources Information Center

    New Jersey State Dept. of Education, Trenton. Div. of Vocational Education.

    Intended to help reduce the number of school eye injuries in New Jersey, this document begins with a brief review of existing legislation regarding eye protection in educational institutions and a list of elements essential in an eye safety program. Second, eye protection equipment is examined in terms of: the advantages of safety spectacles over…

  7. The role of Pax genes in eye evolution.

    PubMed

    Kozmik, Zbynek

    2008-03-18

    Anatomically widely different designs of animal eyes have long been thought to arise independently multiple times during evolution. This morphology-based view has been challenged by the identification of a highly conserved transcription factor Pax6 that plays a key role in eye development in both flies and mammals. The origin of Pax genes predates the origin of eyes and the nervous system since a PaxB-like gene, belonging to the Pax2/5/8 gene subfamily, was identified in sponge lacking nervous system. Structurally similar PaxB gene is implicated in visual system development in jellyfish, the most basal organism possessing complex eyes. The widespread use of Pax genes in the genetic program underlying eye formation throughout the animal kingdom raises a question why certain transcription factors have been frequently redeployed to build eyes. A model is proposed that provides a plausible explanation for the apparently ancient role of Pax genes in eye evolution. PMID:18331895

  8. Dry Eye Disease and Microbial Keratitis: Is There a Connection?

    PubMed Central

    Narayanan, Srihari; Redfern, Rachel L.; Miller, William L.; Nichols, Kelly K.; McDermott, Alison M.

    2013-01-01

    Dry eye is a common ocular surface disease of multifactorial etiology characterized by elevated tear osmolality and inflammation leading to a disrupted ocular surface. The latter is a risk factor for ocular surface infection, yet overt infection is not commonly seen clinically in the typical dry eye patient. This suggests that important innate mechanisms operate to protect the dry eye from invading pathogens. This article reviews the current literature on epidemiology of ocular surface infection in dry eye patients and laboratory-based studies on innate immune mechanisms operating at the ocular surface and their alterations in human dry eye and animal models. The review highlights current understanding of innate immunity in dry eye and identifies gaps in our knowledge to help direct future studies to further unravel the complexities of dry eye disease and its sequelae. PMID:23583043

  9. The incidence of acute hospital-treated eye injuries.

    PubMed

    Karlson, T A; Klein, B E

    1986-10-01

    Little information is available on the incidence and severity of eye injuries despite the disfigurement and vision loss they cause. From a population-based study in Dane County, Wisconsin, the incidence of acute hospital-treated eye injuries was 423/100,000 residents in 1979. The most common causes of eye injuries were assaults, work-related events, sports and recreational activities, motor vehicle crashes, and falls. Consumer products were involved in almost 70% (9/13) of severe eye injuries classified as severe. Injuries from fireworks were not found at all in this population. Implementing known strategies for eye injury prevention would substantially reduce their incidence. These include requiring certified eye protectors at workplaces and in sports activities whenever possible rather than making their use voluntary. For the preponderance of eye injuries, however, modifying potentially hazardous consumer products, including the interior of passenger cars, will be necessary. PMID:3767676

  10. Structural Neural Substrates of Reading the Mind in the Eyes

    PubMed Central

    Sato, Wataru; Kochiyama, Takanori; Uono, Shota; Sawada, Reiko; Kubota, Yasutaka; Yoshimura, Sayaka; Toichi, Motomi

    2016-01-01

    The ability to read the minds of others in their eyes plays an important role in human adaptation to social environments. Behavioral studies have resulted in the development of a test to measure this ability (Reading the Mind in the Eyes Test, revised version; Eyes Test), and have demonstrated that this ability is consistent over time. Although functional neuroimaging studies revealed brain activation while performing the Eyes Test, the structural neural substrates supporting consistent performance on the Eyes Test remain unclear. In this study, we assessed the Eyes Test and analyzed structural magnetic resonance images using voxel-based morphometry (VBM) in healthy participants. Test performance was positively associated with the gray matter volumes of the dorsomedial prefrontal cortex, inferior parietal lobule (temporoparietal junction), and precuneus in the left hemisphere. These results suggest that the fronto-temporoparietal network structures support the consistent ability to read the mind in the eyes. PMID:27148008

  11. Investigating the Temporal Patterns within and between Intrinsic Connectivity Networks under Eyes-Open and Eyes-Closed Resting States: A Dynamical Functional Connectivity Study Based on Phase Synchronization

    PubMed Central

    Wang, Xun-Heng; Li, Lihua; Xu, Tao; Ding, Zhongxiang

    2015-01-01

    The brain active patterns were organized differently under resting states of eyes open (EO) and eyes closed (EC). The altered voxel-wise and regional-wise resting state active patterns under EO/EC were found by static analysis. More importantly, dynamical spontaneous functional connectivity has been observed in the resting brain. To the best of our knowledge, the dynamical mechanisms of intrinsic connectivity networks (ICNs) under EO/EC remain largely unexplored. The goals of this paper were twofold: 1) investigating the dynamical intra-ICN and inter-ICN temporal patterns during resting state; 2) analyzing the altered dynamical temporal patterns of ICNs under EO/EC. To this end, a cohort of healthy subjects with scan conditions of EO/EC were recruited from 1000 Functional Connectomes Project. Through Hilbert transform, time-varying phase synchronization (PS) was applied to evaluate the inter-ICN synchrony. Meanwhile, time-varying amplitude was analyzed as dynamical intra-ICN temporal patterns. The results found six micro-states of inter-ICN synchrony. The medial visual network (MVN) showed decreased intra-ICN amplitude during EC relative to EO. The sensory-motor network (SMN) and auditory network (AN) exhibited enhanced intra-ICN amplitude during EC relative to EO. Altered inter-ICN PS was found between certain ICNs. Particularly, the SMN and AN exhibited enhanced PS to other ICNs during EC relative to EO. In addition, the intra-ICN amplitude might influence the inter-ICN synchrony. Moreover, default mode network (DMN) might play an important role in information processing during EO/EC. Together, the dynamical temporal patterns within and between ICNs were altered during different scan conditions of EO/EC. Overall, the dynamical intra-ICN and inter-ICN temporal patterns could benefit resting state fMRI-related research, and could be potential biomarkers for human functional connectome. PMID:26469182

  12. Rational design of a novel azoimine appended maleonitrile-based Salen chemosensor for rapid naked-eye detection of copper(II) ion in aqueous media.

    PubMed

    Rezaeian, Khatereh; Khanmohammadi, Hamid; Arab, Vajihe

    2015-12-01

    Achieving specific selectivity and high sensitivity for the colorimetric recognition of copper(II) ions in aqueous media over a complex background of potentially competing metal ions is inherently challenging in sensor development. Thus, a novel azo-azomethine receptor (L) based on the combination of 2-amino-3-(5-bromo-2-hydroxybenzylamino)maleonitrile and azo-coupled salicylaldehyde scaffold has been designed and synthesized for the naked-eye and rapid detection of Cu(2+) ion at trace level in a wide pH range. Accordingly, the devised chemosensor distinguished Cu(2+) from other metal ions by distinct color change from light yellow to light brown without any expensive equipment. The binding stoichiometry between Cu(2+) and L has been investigated using Job's plot and MALDI-TOF mass analysis. Remarkably, the current sensor can detect Cu(2+) ions even at 1.07 μM level, which is lower than the World Health Organization (WHO) permissible level (30 μM) in drinking water. Furthermore, sensor L was successfully utilized in the preparation of test strips for the detection of copper(II) ions from aqueous environment. PMID:26184468

  13. Image based remote sensing method for modeling black-eyed beans ( Vigna unguiculata) Leaf Area Index (LAI) and Crop Height (CH) over Cyprus

    NASA Astrophysics Data System (ADS)

    Papadavid, Giorgos; Fasoula, Dionysia; Hadjimitsis, Michael; Skevi Perdikou, P.; Hadjimitsis, Diofantos G.

    2013-03-01

    In this paper, Leaf Area Index (LAI) and Crop Height (CH) are modeled to the most known spectral vegetation index — NDVI — using remotely sensed data. This approach has advantages compared to the classic approaches based on a theoretical background. A GER-1500 field spectro-radiometer was used in this study in order to retrieve the necessary spectrum data for estimating a spectral vegetation index (NDVI), for establishing a semiempirical relationship between black-eyed beans' canopy factors and remotely sensed data. Such semi-empirical models can be used then for agricultural and environmental studies. A field campaign was undertaken with measurements of LAI and CH using the Sun-Scan canopy analyzer, acquired simultaneously with the spectroradiometric (GER1500) measurements between May and June of 2010. Field spectroscopy and remotely sensed imagery have been combined and used in order to retrieve and validate the results of this study. The results showed that there are strong statistical relationships between LAI or CH and NDVI which can be used for modeling crop canopy factors (LAI, CH) to remotely sensed data. The model for each case was verified by the factor of determination. Specifically, these models assist to avoid direct measurements of the LAI and CH for all the dates for which satellite images are available and support future users or future studies regarding crop canopy parameters.

  14. Image based remote sensing method for modeling black-eyed beans (Vigna unguiculata) Leaf Area Index (LAI) and Crop Height (CH) over Cyprus

    NASA Astrophysics Data System (ADS)

    Papadavid, Giorgos; Fasoula, Dionysia; Hadjimitsis, Michael; Skevi Perdikou, P.; Hadjimitsis, Diofantos

    2013-03-01

    In this paper, Leaf Area Index (LAI) and Crop Height (CH) are modeled to the most known spectral vegetation index — NDVI — using remotely sensed data. This approach has advantages compared to the classic approaches based on a theoretical background. A GER-1500 field spectro-radiometer was used in this study in order to retrieve the necessary spectrum data for estimating a spectral vegetation index (NDVI), for establishing a semiempirical relationship between black-eyed beans' canopy factors and remotely sensed data. Such semi-empirical models can be used then for agricultural and environmental studies. A field campaign was undertaken with measurements of LAI and CH using the Sun-Scan canopy analyzer, acquired simultaneously with the spectroradiometric (GER1500) measurements between May and June of 2010. Field spectroscopy and remotely sensed imagery have been combined and used in order to retrieve and validate the results of this study. The results showed that there are strong statistical relationships between LAI or CH and NDVI which can be used for modeling crop canopy factors (LAI, CH) to remotely sensed data. The model for each case was verified by the factor of determination. Specifically, these models assist to avoid direct measurements of the LAI and CH for all the dates for which satellite images are available and support future users or future studies regarding crop canopy parameters.

  15. The injured eye

    PubMed Central

    Scott, Robert

    2011-01-01

    Eye injuries come at a high cost to society and are avoidable. Ocular blast injuries can be primary, from the blast wave itself; secondary, from fragments carried by the blast wind; tertiary; due to structural collapse or being thrown against a fixed object; or quaternary, from burns and indirect injuries. Ballistic eye protection significantly reduces the incidence of eye injuries and should be encouraged from an early stage in Military training. Management of an injured eye requires meticulous history taking, evaluation of vision that measures the acuity and if there is a relative pupillary defect as well as careful inspection of the eyes, under anaesthetic if necessary. A lateral canthotomy with cantholysis should be performed immediately if there is a sight-threatening retrobulbar haemorrhage. Systemic antibiotics should be prescribed if there is a suspected penetrating or perforating injury. A ruptured globe should be protected by an eye shield. Primary repair of ruptured globes should be performed in a timely fashion. Secondary procedures will often be required at a later date to achieve sight preservation. A poor initial visual acuity is not a guarantee of a poor final result. The final result can be predicted after approximately 3–4 weeks. Future research in eye injuries attempts to reduce scarring and neuronal damage as well as to promote photoreceptor rescue, using post-transcriptional inhibition of cell death pathways and vaccination to promote neural recovery. Where the sight has been lost sensory substitution of a picture from a spectacle mounted video camera to the touch receptors of the tongue can be used to achieve appreciation of the outside world. PMID:21149360

  16. Evaluating website navigability: validation of a tool-based approach through two eye-tracking user studies

    NASA Astrophysics Data System (ADS)

    Katsanos, Christos; Tselios, Nikolaos; Avouris, Nikolaos

    2010-04-01

    Following information scent has been established as a metaphor to describe a user's behaviour while navigating an information space by successively selecting hyperlinks. This metaphor suggests that users assess the profitability of following a particular hyperlink based on its perceived semantic association with their goal. The purpose of this paper is to study how information scent, this important attribute of hypermedia navigability, influences concurrently four aspects of users' behaviour while exploring a website: (1) distribution of attention; (2) confidence in choice of link; (3) efficiency; and (4) effectiveness. It was found that in webpages with high scent, users were significantly more focused, confident of their choices, efficient and effective compared to webpages with ambiguous scent. The findings of the study are discussed in comparison with results obtained from a previously conducted analysis using InfoScent Evaluator (ISEtool), a tool that has been proposed to facilitate scent evaluation of websites. This comparison provided support for the effectiveness of ISEtool in indicating potential scent-related navigability problems. We argue that such a tool-based approach can facilitate hypermedia design by reducing the resources and expertise required, and by providing the necessary flexibility for practitioners.

  17. Design and Implementation of Real-Time Off-Grid Detection Tool Based on FNET/GridEye

    SciTech Connect

    Guo, Jiahui; Zhang, Ye; Liu, Yilu; Young II, Marcus Aaron; Irminger, Philip; Dimitrovski, Aleksandar D; Willging, Patrick

    2014-01-01

    Real-time situational awareness tools are of critical importance to power system operators, especially during emergencies. The availability of electric power has become a linchpin of most post disaster response efforts as it is the primary dependency for public and private sector services, as well as individuals. Knowledge of the scope and extent of facilities impacted, as well as the duration of their dependence on backup power, enables emergency response officials to plan for contingencies and provide better overall response. Based on real-time data acquired by Frequency Disturbance Recorders (FDRs) deployed in the North American power grid, a real-time detection method is proposed. This method monitors critical electrical loads and detects the transition of these loads from an on-grid state, where the loads are fed by the power grid to an off-grid state, where the loads are fed by an Uninterrupted Power Supply (UPS) or a backup generation system. The details of the proposed detection algorithm are presented, and some case studies and off-grid detection scenarios are also provided to verify the effectiveness and robustness. Meanwhile, the algorithm has already been implemented based on the Grid Solutions Framework (GSF) and has effectively detected several off-grid situations.

  18. Eye movements and information geometry.

    PubMed

    Lenz, Reiner

    2016-08-01

    The human visual system uses eye movements to gather visual information. They act as visual scanning processes and can roughly be divided into two different types: small movements around fixation points and larger movements between fixation points. The processes are often modeled as random walks, and recent models based on heavy tail distributions, also known as Levý flights, have been used in these investigations. In contrast to these approaches we do not model the stochastic processes, but we will show that the step lengths of the movements between fixation points follow generalized Pareto distributions (GPDs). We will use general arguments from the theory of extreme value statistics to motivate the usage of the GPD and show empirically that the GPDs provide good fits for measured eye tracking data. In the framework of information geometry the GPDs with a common threshold form a two-dimensional Riemann manifold with the Fisher information matrix as a metric. We compute the Fisher information matrix for the GPDs and introduce a feature vector describing a GPD by its parameters and different geometrical properties of its Fisher information matrix. In our statistical analysis we use eye tracker measurements in a database with 15 observers viewing 1003 images under free-viewing conditions. We use Matlab functions with their standard parameter settings and show that a naive Bayes classifier using the eigenvalues of the Fisher information matrix provides a high classification rate identifying the 15 observers in the database. PMID:27505658

  19. A bare-eye based one-step signal amplified semiquantitative immunochromatographic assay for the detection of imidacloprid in Chinese cabbage samples.

    PubMed

    Fang, Qingkui; Wang, Limin; Cheng, Qi; Cai, Jia; Wang, Yulong; Yang, Mingming; Hua, Xiude; Liu, Fengquan

    2015-06-30

    A novel bare-eye based one-step signal amplified semi-quantitative immunochromatographic assay (SAS-ICA) was developed for detection of the pesticide imidacloprid. This method was based on competitive immunoreactions. Signal amplification was achieved by dual labeling of the test lines (TLs) on the strip using high affinity nanogold-biotinylated anti-imidacloprid mAb (BAb) and nanogold-streptavidin (Sa) probes. The relative color intensities of three TLs (TL-I, TL-II and TL-III) on a nitrocellulose (NC) membrane were used for direct visual analysis of the SAS-ICA strips, and could be used for semi-quantitation of analyte concentrations by observing what TLs disappeared in the amplification zone. Under optimized conditions, the following imidacloprid concentration ranges would be detected by visual examination of the SAS-ICA strip: 0-5ngmL(-1) (negative samples), and 5-25ngmL(-1), 25-250ngmL(-1), 250-1000ngmL(-1) and >1000ngmL(-1) (positive samples). The sensitivity (the visual detection limit (VDL) of TL-III) and semi-quantitative analytical capacity (when TL-III disappeared completely) of the SAS-ICA strip were 10-fold and 160-fold higher than those of traditional ICA, respectively. The developed SAS-ICA strip was applied to the analysis of spiked and authentic contaminated Chinese cabbage samples in the laboratory and under field conditions, and the results were validated by high-performance liquid chromatography (HPLC). This process could be adopted as a potential generous technique for all ICA-based detection methods. PMID:26041523

  20. A bird's eye view of anisatin induced convulsive seizures in brain by a (1)H NMR based metabolic approach.

    PubMed

    Wei, Dan-Dan; Ge-Dong; Guo, Ping-Ping; Wang, Jun-Song; Li, Ming-Hui; Yang, Ming-Hua; Kong, Ling-Yi

    2014-11-01

    Anisatin is the main convulsant component in plants of the genus Illicium, many of which are important spices or folk medicines. The neurotoxicity of anisatin has been widely investigated, mainly focusing on its action on the γ-amino butyrate (GABA) system; however, little is known about the metabolic alterations that it causes. In this study, a NMR-based metabolomic approach was performed on the extracts of cortexes and cerebellums of mice administered with anisatin to explore the metabolic events associated with its intoxication. Orthogonal partial least squares-discriminant analysis (OPLS-DA) revealed many differential metabolites that indicated metabolic disturbance in neurotransmission and neuromodulation (GABA, glutamate, glutamine, and taurine), stress of reactive oxygen species (ROS) (ascorbate, phosphatidylcholine, choline, and ethanolamine), energy metabolism (NAD(+)i.e., nicotinamide-adenine dinucleotide, lactate, citrate, fumarate, creatine/phosphocreatine, and creatinine), amino acid metabolism (leucine, isoleucine, valine, phenylalanine, tyrosine, tryptophan, alanine, threonine, and glycine) and nucleic acid metabolism (NAD(+), nicotinamide/niacinamide, adenosine, and guanosine). This pilot metabolomic study on anisatin intoxication should help to develop a holistic view of convulsive seizures induced by anisatin, and provide a better understanding of the mechanisms. PMID:25133938

  1. New pediatric vision screener employing polarization-modulated, retinal-birefringence-scanning-based strabismus detection and bull's eye focus detection with an improved target system: opto-mechanical design and operation

    NASA Astrophysics Data System (ADS)

    Irsch, Kristina; Gramatikov, Boris I.; Wu, Yi-Kai; Guyton, David L.

    2014-06-01

    Amblyopia ("lazy eye") is a major public health problem, caused by misalignment of the eyes (strabismus) or defocus. If detected early in childhood, there is an excellent response to therapy, yet most children are detected too late to be treated effectively. Commercially available vision screening devices that test for amblyopia's primary causes can detect strabismus only indirectly and inaccurately via assessment of the positions of external light reflections from the cornea, but they cannot detect the anatomical feature of the eyes where fixation actually occurs (the fovea). Our laboratory has been developing technology to detect true foveal fixation, by exploiting the birefringence of the uniquely arranged Henle fibers delineating the fovea using retinal birefringence scanning (RBS), and we recently described a polarization-modulated approach to RBS that enables entirely direct and reliable detection of true foveal fixation, with greatly enhanced signal-to-noise ratio and essentially independent of corneal birefringence (a confounding variable with all polarization-sensitive ophthalmic technology). Here, we describe the design and operation of a new pediatric vision screener that employs polarization-modulated, RBS-based strabismus detection and bull's eye focus detection with an improved target system, and demonstrate the feasibility of this new approach.

  2. New pediatric vision screener employing polarization-modulated, retinal-birefringence-scanning-based strabismus detection and bull's eye focus detection with an improved target system: opto-mechanical design and operation.

    PubMed

    Irsch, Kristina; Gramatikov, Boris I; Wu, Yi-Kai; Guyton, David L

    2014-06-01

    Amblyopia ("lazy eye") is a major public health problem, caused by misalignment of the eyes (strabismus) or defocus. If detected early in childhood, there is an excellent response to therapy, yet most children are detected too late to be treated effectively. Commercially available vision screening devices that test for amblyopia's primary causes can detect strabismus only indirectly and inaccurately via assessment of the positions of external light reflections from the cornea, but they cannot detect the anatomical feature of the eyes where fixation actually occurs (the fovea). Our laboratory has been developing technology to detect true foveal fixation, by exploiting the birefringence of the uniquely arranged Henle fibers delineating the fovea using retinal birefringence scanning (RBS), and we recently described a polarization-modulated approach to RBS that enables entirely direct and reliable detection of true foveal fixation, with greatly enhanced signal-to-noise ratio and essentially independent of corneal birefringence (a confounding variable with all polarization-sensitive ophthalmic technology). Here, we describe the design and operation of a new pediatric vision screener that employs polarization-modulated, RBS-based strabismus detection and bull's eye focus detection with an improved target system, and demonstrate the feasibility of this new approach.

  3. Integrating eye tracking and motion sensor on mobile phone for interactive 3D display

    NASA Astrophysics Data System (ADS)

    Sun, Yu-Wei; Chiang, Chen-Kuo; Lai, Shang-Hong

    2013-09-01

    In this paper, we propose an eye tracking and gaze estimation system for mobile phone. We integrate an eye detector, cornereye center and iso-center to improve pupil detection. The optical flow information is used for eye tracking. We develop a robust eye tracking system that integrates eye detection and optical-flow based image tracking. In addition, we further incorporate the orientation sensor information from the mobile phone to improve the eye tracking for accurate gaze estimation. We demonstrate the accuracy of the proposed eye tracking and gaze estimation system through experiments on some public video sequences as well as videos acquired directly from mobile phone.

  4. COMPU-EYE: a high resolution computational compound eye.

    PubMed

    Lee, Woong-Bi; Jang, Hwanchol; Park, Sangjun; Song, Young Min; Lee, Heung-No

    2016-02-01

    In nature, the compound eyes of arthropods have evolved towards a wide field of view (FOV), infinite depth of field and fast motion detection. However, compound eyes have inferior resolution when compared with the camera-type eyes of vertebrates, owing to inherent structural constraints such as the optical performance and the number of ommatidia. For resolution improvements, in this paper, we propose COMPUtational compound EYE (COMPU-EYE), a new design that increases acceptance angles and uses a modern digital signal processing (DSP) technique. We demonstrate that the proposed COMPU-EYE provides at least a four-fold improvement in resolution.

  5. Synthesis and studies of selective chemosensor for naked-eye detection of anions and cations based on a new Schiff-base derivative.

    PubMed

    Orojloo, Masoumeh; Amani, Saeid

    2016-10-01

    A new chromogenic receptor, 4-((2,4-dichlorophenyl)diazenyl)-2-(3-hydroxypropylimino) methyl)phenol, has been designed and synthesized for quantitative and low-cost detection of various biological anions and cations. The dye was characterized by elemental analyses, infrared, UV-visible spectroscopy, and NMR spectroscopy. Upon the addition of F(-) and H2PO4(-) to the solution of chemosensor in DMSO, the dramatic naked eye detectable color changes were observed from yellow to red and orange with a limit of detection (LOD) of 1.66×10(-6)mol. L(-1) and 1.24×10(-6)mol. L(-1) at room temperature, respectively. The chemosensor showed visual changes towards cations, such as Al(3+), Cu(2+), Fe(3+), and Cr(3+), in DMSO/water (9:1). The detection limit of receptor L for the analysis of Al(3+) ion was calculated to be 3.02×10(-6)mol. L(-1). The anion recognition property of the receptor via proton transfer was monitored by UV-visible titration and (1)HNMR spectroscopy. The binding constant (Ka) and stoichiometry of the host-guest complexes formed were determined by the Benesi-Hildebrand (B-H) plot and Job's method, respectively. PMID:27474311

  6. Synthesis and studies of selective chemosensor for naked-eye detection of anions and cations based on a new Schiff-base derivative.

    PubMed

    Orojloo, Masoumeh; Amani, Saeid

    2016-10-01

    A new chromogenic receptor, 4-((2,4-dichlorophenyl)diazenyl)-2-(3-hydroxypropylimino) methyl)phenol, has been designed and synthesized for quantitative and low-cost detection of various biological anions and cations. The dye was characterized by elemental analyses, infrared, UV-visible spectroscopy, and NMR spectroscopy. Upon the addition of F(-) and H2PO4(-) to the solution of chemosensor in DMSO, the dramatic naked eye detectable color changes were observed from yellow to red and orange with a limit of detection (LOD) of 1.66×10(-6)mol. L(-1) and 1.24×10(-6)mol. L(-1) at room temperature, respectively. The chemosensor showed visual changes towards cations, such as Al(3+), Cu(2+), Fe(3+), and Cr(3+), in DMSO/water (9:1). The detection limit of receptor L for the analysis of Al(3+) ion was calculated to be 3.02×10(-6)mol. L(-1). The anion recognition property of the receptor via proton transfer was monitored by UV-visible titration and (1)HNMR spectroscopy. The binding constant (Ka) and stoichiometry of the host-guest complexes formed were determined by the Benesi-Hildebrand (B-H) plot and Job's method, respectively.

  7. Penetrating eye injuries.

    PubMed Central

    Patel, B C

    1989-01-01

    A review of all penetrating eye injuries treated at the Manchester Royal Eye Hospital over four years (1 January 1982-31 December 1985) was undertaken. A total of 202 penetrating eye injuries were seen of which 68 (34%) were in children under the age of 15 years. Airgun, dart, and knife injuries accounted for 28 (41%) of the injuries. Thirty seven patients (54%) achieved a good visual result (6/12 or better) and eight (12%) had enucleations. The period of inpatient treatment ranged from two to 18 days. From the analysis of the activities at the time of the injury, many of the injuries can be considered to be preventable. PMID:2705791

  8. Short-term memory across eye blinks.

    PubMed

    Irwin, David E

    2014-01-01

    The effect of eye blinks on short-term memory was examined in two experiments. On each trial, participants viewed an initial display of coloured, oriented lines, then after a retention interval they viewed a test display that was either identical or different by one feature. Participants kept their eyes open throughout the retention interval on some blocks of trials, whereas on others they made a single eye blink. Accuracy was measured as a function of the number of items in the display to determine the capacity of short-term memory on blink and no-blink trials. In separate blocks of trials participants were instructed to remember colour only, orientation only, or both colour and orientation. Eye blinks reduced short-term memory capacity by approximately 0.6-0.8 items for both feature and conjunction stimuli. A third, control, experiment showed that a button press during the retention interval had no effect on short-term memory capacity, indicating that the effect of an eye blink was not due to general motoric dual-task interference. Eye blinks might instead reduce short-term memory capacity by interfering with attention-based rehearsal processes.

  9. Establishing an indigenous tele-eye care service.

    PubMed

    Kanagasingam, Yogesan; Boyle, Justin; Vignarajan, Janardhan; Di Xiao; Ming Zhang

    2015-08-01

    We describe the establishment of a new tele-eye care solution over a Broadband Satellite service, connecting metropolitan-based ophthalmologists to patients with eye conditions in rural and remote Australia. A trial of the service demonstrates the ability of the telehealth system to close the gap in access to eye care services for adult Australians living in under-served rural and remote communities, preventing needless blindness. PMID:26736582

  10. Eye Movements and Perception.

    ERIC Educational Resources Information Center

    Gaarder, Kenneth

    An explanation of visual perception is presented using physiological facts, analogies to digital computers, and analogies to the structure of written languages. According to the explanation, visual input is discontinuous, with the discontinuities mediated by and correlated with the jumps of the eye. This is analogous to the gated and buffer-stored…

  11. Through Students' Eyes.

    ERIC Educational Resources Information Center

    McLean-Donaldson, Karen B.

    1994-01-01

    Identifies how students perceive racism and its effects on student learning and whether antiracist/multicultural arts (ARMA) curricula can empower students to address racism in schools. Results show racism, through students' eyes, damages learning, attitudes, and behavior. ARMA positively effected students' ability to confront racism within their…

  12. Through Our Eyes

    ERIC Educational Resources Information Center

    Narva, Sara

    2009-01-01

    Through Our Eyes was a multimedia performance created in collaboration with the author's five modern dance students. Through video, sound, and dance, the piece shows some ways race has affected their lives. The author did not set out at the beginning of the semester to make this project in her dance class. It was born out of a hard conversation,…

  13. Dynamic Eye Model.

    ERIC Educational Resources Information Center

    Journal of Science and Mathematics Education in Southeast Asia, 1981

    1981-01-01

    Instructions (with diagrams and parts list) are provided for constructing an eye model with a pliable lens made from a plastic bottle which can vary its convexity to accommodate changing positions of an object being viewed. Also discusses concepts which the model can assist in developing. (Author/SK)

  14. [Eye and the pregnacy].

    PubMed

    Dima, Anne Marie

    2012-01-01

    Pregnancy is associated with changes in many organs and systems including the eyes. Sometimes in pregnancy may appear physiological and pathological ocular changes that may be associated with pre-existing problems. In such cases it is very important interdisciplinary collaboration gynecologist, ophthalmologist.

  15. Pursuit Eye Movements

    NASA Technical Reports Server (NTRS)

    Krauzlis, Rich; Stone, Leland; Null, Cynthia H. (Technical Monitor)

    1998-01-01

    When viewing objects, primates use a combination of saccadic and pursuit eye movements to stabilize the retinal image of the object of regard within the high-acuity region near the fovea. Although these movements involve widespread regions of the nervous system, they mix seamlessly in normal behavior. Saccades are discrete movements that quickly direct the eyes toward a visual target, thereby translating the image of the target from an eccentric retinal location to the fovea. In contrast, pursuit is a continuous movement that slowly rotates the eyes to compensate for the motion of the visual target, minimizing the blur that can compromise visual acuity. While other mammalian species can generate smooth optokinetic eye movements - which track the motion of the entire visual surround - only primates can smoothly pursue a single small element within a complex visual scene, regardless of the motion elsewhere on the retina. This ability likely reflects the greater ability of primates to segment the visual scene, to identify individual visual objects, and to select a target of interest.

  16. Eye of the Beholder

    ERIC Educational Resources Information Center

    Rogers, Michael

    2010-01-01

    Art, like beauty, as the adage goes, is in the eye of the beholder. Art also is a living, breathing thing that evolves over time, so what is considered "art" is ever changing--how many of the great artists whose works today sell for fortunes were failures during their lifetime? The 20th century unknowingly gave birth to new variations of art that…

  17. Eyes for Learning

    ERIC Educational Resources Information Center

    Orfield, Antonia

    2008-01-01

    Vision is the dominant sense, and the eyes are connected with almost every other part of the brain. If the vision system is poorly developed, children trying to learn suffer. Without good up close vision, students are handicapped even if no one knows or suspects it--they may not even know it themselves. Students do not know that the way they see…

  18. An eye for inspiration

    NASA Astrophysics Data System (ADS)

    2009-11-01

    The discovery that the eye of a particular mantis shrimp has an achromatic quarter-waveplate that is superior to modern-day devices could be a source of inspiration to those designing optical components. Nature Photonics spoke to Nicholas Roberts, one of the researchers involved in the study.

  19. The Eyes Have It.

    ERIC Educational Resources Information Center

    Walsh, Janet

    1982-01-01

    Discusses the health hazards of working with the visual display systems of computers, in particular the eye problems associated with long-term use of video display terminals. Excerpts from and ordering information for the National Institute for Occupational Safety and Health report on such hazards are included. (JJD)

  20. Self-Reported Utilization of Eye Care among Latinos: The Los Angeles Latino Eye Study (LALES)

    PubMed Central

    Morales, Leo S.; Varma, Rohit; Paz, Sylvia H.; Lai, Mei Ying; Mazhar, Kashif; Andersen, Ronald M.; Azen, Stanley P.

    2009-01-01

    Purpose To identify the prevalence and determinants of self-reported eye care utilization in Latinos. Design Population-based ocular epidemiological study in Latinos age 40+ living in La Puente, California. Participants 5,455 participants. Methods Univariate, multivariable and stepwise logistic regression analyses were conducted to identify predisposing, enabling and need variables associated with self-reported eye care utilization. Main Outcome Measures Prevalence of self-reported utilization: eye care visit, having had a dilated examination in the past 12 months, ever having had a dilated examination, and odds ratios for factors associated with self-reported utilization. Results Overall, 36% of participants reported an eye care visit and 19% reported having a dilated examination in the past year. Fifty-seven percent reported ever having had a dilated eye examination. Greater eye care utilization was associated with older age, female gender, bilingual language proficiency (English and Spanish), more education, having health insurance, having a usual place for care, having a regular provider of care, greater number of co-morbidities, visual impairment, and lower vision-specific quality of life scores. Conclusions Increasing utilization and access to eye care for Latinos should be a priority because visual impairment has significant impacts on well-being and mortality. PMID:20018380

  1. Comparison of eye imaging pattern recognition using neural network

    NASA Astrophysics Data System (ADS)

    Bukhari, W. M.; Syed A., M.; Nasir, M. N. M.; Sulaima, M. F.; Yahaya, M. S.

    2015-05-01

    The beauty of eye recognition system that it is used in automatic identifying and verifies a human weather from digital images or video source. There are various behaviors of the eye such as the color of the iris, size of pupil and shape of the eye. This study represents the analysis, design and implementation of a system for recognition of eye imaging. All the eye images that had been captured from the webcam in RGB format must through several techniques before it can be input for the pattern and recognition processes. The result shows that the final value of weight and bias after complete training 6 eye images for one subject is memorized by the neural network system and be the reference value of the weight and bias for the testing part. The target classifies to 5 different types for 5 subjects. The eye images can recognize the subject based on the target that had been set earlier during the training process. When the values between new eye image and the eye image in the database are almost equal, it is considered the eye image is matched.

  2. What eye movements can tell us about sentence comprehension.

    PubMed

    Vasishth, Shravan; von der Malsburg, Titus; Engelmann, Felix

    2013-03-01

    Eye movement data have proven to be very useful for investigating human sentence processing. Eyetracking research has addressed a wide range of questions, such as recovery mechanisms following garden-pathing, the timing of processes driving comprehension, the role of anticipation and expectation in parsing, the role of semantic, pragmatic, and prosodic information, and so on. However, there are some limitations regarding the inferences that can be made on the basis of eye movements. One relates to the nontrivial interaction between parsing and the eye movement control system which complicates the interpretation of eye movement data. Detailed computational models that integrate parsing with eye movement control theories have the potential to unpack the complexity of eye movement data and can therefore aid in the interpretation of eye movements. Another limitation is the difficulty of capturing spatiotemporal patterns in eye movements using the traditional word-based eyetracking measures. Recent research has demonstrated the relevance of these patterns and has shown how they can be analyzed. In this review, we focus on reading, and present examples demonstrating how eye movement data reveal what events unfold when the parser runs into difficulty, and how the parsing system interacts with eye movement control. WIREs Cogn Sci 2013, 4:125-134. doi: 10.1002/wcs.1209 For further resources related to this article, please visit the WIREs website.

  3. Simple Solutions for Dry Eye

    MedlinePlus

    ... are more concentrated in the tear film of dry eye patients. In hot weather, sleep with the windows shut and keep cool with air conditioning. • Dry eye patients often develop or aggravate allergies. An ...

  4. Recognizing and Treating Eye Injuries

    MedlinePlus

    ... and seek medical attention. In case of a chemical burn to the eye: Immediately flush the eye ... Academy Jobs at the Academy Financial Relationships with Industry Medical Disclaimer Privacy Policy Terms of Service For ...

  5. Medicare Benefits and Your Eyes

    MedlinePlus

    ... Eye Health Report Reports and External Resources The Cost of Vision Problems The Future of Vision Vision Problems in the U.S. Healthy Eyes Education Series Online Training and Certification Patient Education Materials ...

  6. New perspectives on eye development and the evolution of eyes and photoreceptors.

    PubMed

    Gehring, W J

    2005-01-01

    , was found to be expressed in the eyes. In contrast to the adults, which have highly evolved eyes, the Planula larva of Tripedalia has single- celled photoreceptors similar to some unicellular protists. For the origin of photoreceptor cells in metazoa, I propose two hypotheses, one based on cellular differentiation and a more speculative one based on symbiosis. The former assumes that photoreceptor cells originated from a colonial protist in which all the cells were photosensitive and subsequent cellular differentiation to give rise to photoreceptor cells. The symbiont hypothesis, which I call the Russian doll model, assumes that photosensitivity arose first in photosynthetic cyanobacteria that were subsequently taken up into red algae as primary chloroplasts. The red algae in turn were taken up by dinoflagellates as secondary chloroplasts and in some species evolved into the most sophisticated eye organelles, as found, for example, in some dinoflagellates like Erythropsis and Warnovia, which lack chloroplasts. Because dinoflagellates are commonly found as symbionts in cnidarians, the dinoflagellates may have transferred their photoreceptor genes to cnidarians. In cnidarians such as Tripedalia the step from photoreceptor organelles to multicellular eyes has occurred. These two hypotheses, the cellular differentiation and the symbiont hypothesis, are not mutually exclusive and are the subject of further investigations.

  7. Combining EEG and eye tracking: identification, characterization, and correction of eye movement artifacts in electroencephalographic data

    PubMed Central

    Plöchl, Michael; Ossandón, José P.; König, Peter

    2012-01-01

    Eye movements introduce large artifacts to electroencephalographic recordings (EEG) and thus render data analysis difficult or even impossible. Trials contaminated by eye movement and blink artifacts have to be discarded, hence in standard EEG-paradigms subjects are required to fixate on the screen. To overcome this restriction, several correction methods including regression and blind source separation have been proposed. Yet, there is no automated standard procedure established. By simultaneously recording eye movements and 64-channel-EEG during a guided eye movement paradigm, we investigate and review the properties of eye movement artifacts, including corneo-retinal dipole changes, saccadic spike potentials and eyelid artifacts, and study their interrelations during different types of eye- and eyelid movements. In concordance with earlier studies our results confirm that these artifacts arise from different independent sources and that depending on electrode site, gaze direction, and choice of reference these sources contribute differently to the measured signal. We assess the respective implications for artifact correction methods and therefore compare the performance of two prominent approaches, namely linear regression and independent component analysis (ICA). We show and discuss that due to the independence of eye artifact sources, regression-based correction methods inevitably over- or under-correct individual artifact components, while ICA is in principle suited to address such mixtures of different types of artifacts. Finally, we propose an algorithm, which uses eye tracker information to objectively identify eye-artifact related ICA-components (ICs) in an automated manner. In the data presented here, the algorithm performed very similar to human experts when those were given both, the topographies of the ICs and their respective activations in a large amount of trials. Moreover it performed more reliable and almost twice as effective than human experts

  8. Prevalence of skeletal and eye malformations in frogs from north-central United States: estimations based on collections from randomly selected sites

    USGS Publications Warehouse

    Schoff, P.K.; Johnson, C.M.; Schotthoefer, A.M.; Murphy, J.E.; Lieske, C.; Cole, R.A.; Johnson, L.B.; Beasley, V.R.

    2003-01-01

    Skeletal malformation rates for several frog species were determined in a set of randomly selected wetlands in the north-central USA over three consecutive years. In 1998, 62 sites yielded 389 metamorphic frogs, nine (2.3%) of which had skeletal or eye malformations. A subset of the original sites was surveyed in the following 2 yr. In 1999, 1,085 metamorphic frogs were collected from 36 sites and 17 (1.6%) had skeletal or eye malformations, while in 2000, examination of 1,131 metamorphs yielded 16 (1.4%) with skeletal or eye malformations. Hindlimb malformations predominated in all three years, but other abnormalities, involving forelimb, eye, and pelvis were also found. Northern leopard frogs (Rana pipiens) constituted the majority of collected metamorphs as well as most of the malformed specimens. However, malformations were also noted in mink frogs (R. septentrionalis), wood frogs (R. sylvatica), and gray tree frogs (Hyla spp.). The malformed specimens were found in clustered sites in all three years but the cluster locations were not the same in any year. The malformation rates reported here are higher than the 0.3% rate determined for metamorphic frogs collected from similar sites in Minnesota in the 1960s, and thus, appear to represent an elevation of an earlier baseline malformation rate.

  9. Experiments on a Model Eye

    ERIC Educational Resources Information Center

    Arell, Antti; Kolari, Samuli

    1978-01-01

    Explains a laboratory experiment dealing with the optical features of the human eye. Shows how to measure the magnification of the retina and the refractive anomaly of the eye could be used to measure the refractive power of the observer's eye. (GA)

  10. Eye Protection in Kansas Schools.

    ERIC Educational Resources Information Center

    Hay, Kenneth M.; And Others

    A law passed by a state legislature requires that students in industrial arts shops and science laboratories must wear eye protective devices. Explanatory material presents the text of the bill and guidelines for implementation, including--(1) types of eye hazards, (2) types of protective devices, (3) administrating eye safety equipment, (4)…

  11. LIMNOLOGICAL OPTOMETRY: EXAMINING EARTH'S EYE

    EPA Science Inventory

    In Thoreau's Walden, a lake is described as the landscape's most expressive feature and the earth's eye. Collectively, scientists are charged by society to assess, monitor, and remedy maladies of earth's eye in the same way optometrists maintain the health of the human eye. This ...

  12. Reconstructing the eyes of Urbilateria.

    PubMed Central

    Arendt, D; Wittbrodt, J

    2001-01-01

    The shared roles of Pax6 and Six homologues in the eye development of various bilaterians suggest that Urbilateria, the common ancestors of all Bilateria, already possessed some simple form of eyes. Here, we re-address the homology of bilaterian cerebral eyes at the level of eye anatomy, of eye-constituting cell types and of phototransductory molecules. The most widespread eye type found in Bilateria are the larval pigment-cup eyes located to the left and right of the apical organ in primary, ciliary larvae of Protostomia and Deuterostomia. They can be as simple as comprising a single pigment cell and a single photoreceptor cell in inverse orientation. Another more elaborate type of cerebral pigment-cup eyes with an everse arrangement of photoreceptor cells is found in adult Protostomia. Both inverse larval and everse adult eyes employ rhabdomeric photoreceptor cells and thus differ from the chordate cerebral eyes with ciliary photoreceptors. This is highly significant because on the molecular level we find that for phototransduction rhabdomeric versus ciliary photoreceptor cells employ divergent rhodopsins and non-orthologous G-proteins, rhodopsin kinases and arrestins. Our comparison supports homology of cerebral eyes in Protostomia; it challenges, however, homology of chordate and non-chordate cerebral eyes that employ photoreceptor cells with non-orthologous phototransductory cascades. PMID:11604122

  13. Dosimetry and physical treatment planning for iodine eye plaque therapy

    SciTech Connect

    Alberti, W.; Pothmann, B.; Tabor, P.; Muskalla, K.; Hermann, K.P.; Harder, D. )

    1991-05-01

    The dosimetry of eye plaques loaded with iodine-125 seeds (type 6702) was performed by means of computer calculations and measurements with thermoluminescent dosimeters (TLD). Measurements of the depth dose distribution (2-25.5 mm) along the transverse axis of a single seed were performed in water equivalent phantom material. The transverse axis attenuation and geometry factor F(r) was obtained by applying a least squares fit to the measured data. Based on the resulting radial dose function, a computer program was developed which calculates dose distributions within the eye for arbitrary loading and placement of the eye plaque. The computational results were verified by TLD measurements in an eye phantom.

  14. Beam’s-eye-view dosimetrics (BEVD) guided rotational station parameter optimized radiation therapy (SPORT) planning based on reweighted total-variation minimization

    NASA Astrophysics Data System (ADS)

    Kim, Hojin; Li, Ruijiang; Lee, Rena; Xing, Lei

    2015-03-01

    Conventional VMAT optimizes aperture shapes and weights at uniformly sampled stations, which is a generalization of the concept of a control point. Recently, rotational station parameter optimized radiation therapy (SPORT) has been proposed to improve the plan quality by inserting beams to the regions that demand additional intensity modulations, thus formulating non-uniform beam sampling. This work presents a new rotational SPORT planning strategy based on reweighted total-variation (TV) minimization (min.), using beam’s-eye-view dosimetrics (BEVD) guided beam selection. The convex programming based reweighted TV min. assures the simplified fluence-map, which facilitates single-aperture selection at each station for single-arc delivery. For the rotational arc treatment planning and non-uniform beam angle setting, the mathematical model needs to be modified by additional penalty term describing the fluence-map similarity and by determination of appropriate angular weighting factors. The proposed algorithm with additional penalty term is capable of achieving more efficient and deliverable plans adaptive to the conventional VMAT and SPORT planning schemes by reducing the dose delivery time about 5 to 10 s in three clinical cases (one prostate and two head-and-neck (HN) cases with a single and multiple targets). The BEVD guided beam selection provides effective and yet easy calculating methodology to select angles for denser, non-uniform angular sampling in SPORT planning. Our BEVD guided SPORT treatment schemes improve the dose sparing to femoral heads in the prostate and brainstem, parotid glands and oral cavity in the two HN cases, where the mean dose reduction of those organs ranges from 0.5 to 2.5 Gy. Also, it increases the conformation number assessing the dose conformity to the target from 0.84, 0.75 and 0.74 to 0.86, 0.79 and 0.80 in the prostate and two HN cases, while preserving the delivery efficiency, relative to conventional single-arc VMAT plans.

  15. Application of 3-Dimensional Printing Technology to Construct an Eye Model for Fundus Viewing Study

    PubMed Central

    Li, Xinhua; Gao, Zhishan; Yuan, Dongqing; Liu, Qinghuai

    2014-01-01

    Objective To construct a life-sized eye model using the three-dimensional (3D) printing technology for fundus viewing study of the viewing system. Methods We devised our schematic model eye based on Navarro's eye and redesigned some parameters because of the change of the corneal material and the implantation of intraocular lenses (IOLs). Optical performance of our schematic model eye was compared with Navarro's schematic eye and other two reported physical model eyes using the ZEMAX optical design software. With computer aided design (CAD) software, we designed the 3D digital model of the main structure of the physical model eye, which was used for three-dimensional (3D) printing. Together with the main printed structure, polymethyl methacrylate(PMMA) aspherical cornea, variable iris, and IOLs were assembled to a physical eye model. Angle scale bars were glued from posterior to periphery of the retina. Then we fabricated other three physical models with different states of ammetropia. Optical parameters of these physical eye models were measured to verify the 3D printing accuracy. Results In on-axis calculations, our schematic model eye possessed similar size of spot diagram compared with Navarro's and Bakaraju's model eye, much smaller than Arianpour's model eye. Moreover, the spherical aberration of our schematic eye was much less than other three model eyes. While in off- axis simulation, it possessed a bit higher coma and similar astigmatism, field curvature and distortion. The MTF curves showed that all the model eyes diminished in resolution with increasing field of view, and the diminished tendency of resolution of our physical eye model was similar to the Navarro's eye. The measured parameters of our eye models with different status of ametropia were in line with the theoretical value. Conclusions The schematic eye model we designed can well simulate the optical performance of the human eye, and the fabricated physical one can be used as a tool in fundus

  16. Eye-Head Coordination Abnormalities in Schizophrenia

    PubMed Central

    Schwab, Simon; Würmle, Othmar; Razavi, Nadja; Müri, René M.; Altorfer, Andreas

    2013-01-01

    Background Eye-movement abnormalities in schizophrenia are a well-established phenomenon that has been observed in many studies. In such studies, visual targets are usually presented in the center of the visual field, and the subject's head remains fixed. However, in every-day life, targets may also appear in the periphery. This study is among the first to investigate eye and head movements in schizophrenia by presenting targets in the periphery of the visual field. Methodology/Principal Findings Two different visual recognition tasks, color recognition and Landolt orientation tasks, were presented at the periphery (at a visual angle of 55° from the center of the field of view). Each subject viewed 96 trials, and all eye and head movements were simultaneously recorded using video-based oculography and magnetic motion tracking of the head. Data from 14 patients with schizophrenia and 14 controls were considered. The patients had similar saccadic latencies in both tasks, whereas controls had shorter saccadic latencies in the Landolt task. Patients performed more head movements, and had increased eye-head offsets during combined eye-head shifts than controls. Conclusions/Significance Patients with schizophrenia may not be able to adapt to the two different tasks to the same extent as controls, as seen by the former's task-specific saccadic latency pattern. This can be interpreted as a specific oculomotoric attentional dysfunction and may support the hypothesis that schizophrenia patients have difficulties determining the relevance of stimuli. Patients may also show an uneconomic over-performance of head-movements, which is possibly caused by alterations in frontal executive function that impair the inhibition of head shifts. In addition, a model was created explaining 93% of the variance of the response times as a function of eye and head amplitude, which was only observed in the controls, indicating abnormal eye-head coordination in patients with schizophrenia. PMID

  17. Eye movements in depth to visual illusions

    NASA Astrophysics Data System (ADS)

    Wismeijer, D. A.

    2009-10-01

    We perceive the three-dimensional (3D) environment that surrounds us with deceptive effortlessness. In fact, we are far from comprehending how the visual system provides us with this stable perception of the (3D) world around us. This thesis will focus on the interplay between visual perception of depth and its closely related action system, eye movements in depth. The human visual system is comprised of a sensory (input) and an output (motor) system. Processed information from the sensory system can result in two explicit measurable response types: conscious visual perception and ocular motor behavior. It is still a matter of debate whether conscious visual perception and action (including hand- and arm-movements) use the same information or whether the visual system has separate channels processing information for perception and action. In this thesis, we study (1) if separate channels, one for eye movements and one for conscious visual perception, indeed exist, and (2) if so, if there is a direct input from the perceptual pathway to the motor pathway. Assuming that either eye movements and conscious visual perception are based on information from a common source (a negative answer to issue 1) or perception can directly influence, or guide, eye movements (an affirmative answer to research question 2), (eye) movements reflect our conscious visual perception. If so, eye movements could provide us with an alternative method to probe our conscious visual perception, making explicit perceptual reports superfluous. In this thesis we focus on depth perception and the two types of eye movements that are closest related to depth perception, namely vergence (an eye movement that gets a certain depth plane into focus) and saccades (a rapid eye movement to change gaze direction). Over the last 20 years it has been shown that depth perception is based on a weighted combination of depth cues available such as linear perspective, occlusion and binocular disparity. How eye

  18. Nutrition and the eye.

    PubMed

    Congdon, N G; West, K P

    1999-12-01

    The topic "nutrition and the eye" cannot adequately be covered in a single review article; indeed, dozens of books and hundreds of articles have been written on the subject. This review concentrates on three areas in which specific nutrients are known or theorized to have a major impact on vision and the visual system: vitamin A deficiency; antioxidants and their proposed role in the prevention of age-related cataract and macular degeneration; and nutritional optic neuropathies, including those of the recent Cuban epidemic. In addition, this article touches on nutritional treatments that have been suggested for several less common eye diseases and, finally, considers several less prevalent conditions in which deficiency of or excess exposure to a particular nutrient has been associated with ocular pathology. PMID:10662253

  19. [STD in the eye].

    PubMed

    Usui, Masahiko; Minoda, Hirosi

    2009-01-01

    In this paper, we review sexually transmitted diseases (STD) involving the eye. Recently conjunctivitis due to Chlamydia trachomatis in children and adults is increasing, and that of Neisseria gonorrhoeae resistant to multiple antibiotics has attracted special attention in our country. Syphilis has many ocular manifestations such as keratitis, iridocyclitis, retinochorioiditis, and neuritis, etc. Ocular complications related to HIV infection, including HIV retinopathy, cytomegalovirus retinitis, zoster ophthalmics, and Kaposi s sarcoma in conjunctiva are increasing in Japan. Phthirus pubis infection of the eye lid, and human T-cell lymphotropic virus type 1 (HTLV-1)-associated uveitis are occasionally reported. Furthermore conjunctival tumor associated with human papilloma virus (HPV) infection, acute retinal necrosis(ARN) due to herpes simplex virus type 2 (HSV-2), as well as hepatitis B virus (HVB) and hepatitis C virus (HVC) retinopathy are also mentioned in this review. PMID:19177759

  20. Eye movements during transcendental meditation.

    PubMed

    Tebēcis, A K

    1976-01-01

    Characteristic changes in eye movements occurred during meditation with closed eyes in a proportion of subjects experienced in TM. The most common changes were an increase in slow, large-amplitude, 'rolling' eye movements and a concomitant decrease in rapid, low-amplitude, 'jerky' eye movements. Much variation occurred between individuals, however, some subjects showing no differences between TM and non-meditation. Any changes that occurred were not necessarily constant for the whole recording period nor consistent between sessions. The physiological effects of TM are far more variable than previously publicized. In general, the main changes in eye movements during TM are similar to those during passive hypnosis.

  1. [Conservative treatment of dry eye].

    PubMed

    Hefner, J; Reinshagen, H

    2014-11-01

    The use of topic anti-inflammatory drugs has become very important in the treatment of dry eye disease. Besides the basic therapy including tear replacement, use of serum eye drops and mucolytic eye drops, the topical application of corticosteroids and cyclosporin A is more commonly used in moderate to severe forms of dry eye disease. The consistent treatment of Meibomian gland dysfunction as a frequent reason for evaporative dry eye is also of particular importance. Understanding the chronicity of the disease and long-term compliance are the essential for successful therapy of this widespread disease.

  2. [Conservative treatment of dry eye].

    PubMed

    Hefner, J; Reinshagen, H

    2014-11-01

    The use of topic anti-inflammatory drugs has become very important in the treatment of dry eye disease. Besides the basic therapy including tear replacement, use of serum eye drops and mucolytic eye drops, the topical application of corticosteroids and cyclosporin A is more commonly used in moderate to severe forms of dry eye disease. The consistent treatment of Meibomian gland dysfunction as a frequent reason for evaporative dry eye is also of particular importance. Understanding the chronicity of the disease and long-term compliance are the essential for successful therapy of this widespread disease. PMID:25275793

  3. Dry eye syndrome.

    PubMed

    Javadi, Mohammad-Ali; Feizi, Sepehr

    2011-07-01

    Our understanding of keratoconjunctivitis sicca (KCS), also known as dry eye syndrome, has been changed over recent years. Until lately, the condition was thought to be merely due to aqueous tear insufficiency. Today, it is understood that KCS is a multifactorial disorder due to inflammation of the ocular surface and lacrimal gland, neurotrophic deficiency and meibomian gland dysfunction. This change in paradigm has led to the development of new and more effective medications.

  4. Christoph Scheiner's eye studies.

    PubMed

    Daxecker, F

    1992-01-01

    Christoph Scheiner was born in 1573 or 1575. In 1595 he entered into the Order of the Jesuits; he died in 1650. In 1619 his book Oculus, dealing with the optics of the eye, appeared in Innsbruck. The invention of the telescope was of utmost importance for progress in astronomical and physical research. Scheiner himself built telescopes and discovered the sunspots. As a result, an unpleasant priority dispute with Galilei ensued. From 1624 onwards, Scheiner was in Rome, where his main work Rosa Ursina was published in 1630. A part of this book deals with the physiological optics of the eye as well. Some of his discoveries and experiments are taken from these two books: determination of the radius of curvature of the cornea, discovery of the nasal exit of the optic nerve, increase in the radius of curvature of the lens in case of accommodation, Scheiner's procedure (double images with ametropia), refractive indices of various parts of the eye, Scheiner's experiment. Without any doubt, Christoph Scheiner belongs to the foremost scientists of the first half of the 17th century. PMID:1473465

  5. Christoph Scheiner's eye studies.

    PubMed

    Daxecker, F

    1992-01-01

    Christoph Scheiner was born in 1573 or 1575. In 1595 he entered into the Order of the Jesuits; he died in 1650. In 1619 his book Oculus, dealing with the optics of the eye, appeared in Innsbruck. The invention of the telescope was of utmost importance for progress in astronomical and physical research. Scheiner himself built telescopes and discovered the sunspots. As a result, an unpleasant priority dispute with Galilei ensued. From 1624 onwards, Scheiner was in Rome, where his main work Rosa Ursina was published in 1630. A part of this book deals with the physiological optics of the eye as well. Some of his discoveries and experiments are taken from these two books: determination of the radius of curvature of the cornea, discovery of the nasal exit of the optic nerve, increase in the radius of curvature of the lens in case of accommodation, Scheiner's procedure (double images with ametropia), refractive indices of various parts of the eye, Scheiner's experiment. Without any doubt, Christoph Scheiner belongs to the foremost scientists of the first half of the 17th century.

  6. Comprehensive eye evaluation algorithm

    NASA Astrophysics Data System (ADS)

    Agurto, C.; Nemeth, S.; Zamora, G.; Vahtel, M.; Soliz, P.; Barriga, S.

    2016-03-01

    In recent years, several research groups have developed automatic algorithms to detect diabetic retinopathy (DR) in individuals with diabetes (DM), using digital retinal images. Studies have indicated that diabetics have 1.5 times the annual risk of developing primary open angle glaucoma (POAG) as do people without DM. Moreover, DM patients have 1.8 times the risk for age-related macular degeneration (AMD). Although numerous investigators are developing automatic DR detection algorithms, there have been few successful efforts to create an automatic algorithm that can detect other ocular diseases, such as POAG and AMD. Consequently, our aim in the current study was to develop a comprehensive eye evaluation algorithm that not only detects DR in retinal images, but also automatically identifies glaucoma suspects and AMD by integrating other personal medical information with the retinal features. The proposed system is fully automatic and provides the likelihood of each of the three eye disease. The system was evaluated in two datasets of 104 and 88 diabetic cases. For each eye, we used two non-mydriatic digital color fundus photographs (macula and optic disc centered) and, when available, information about age, duration of diabetes, cataracts, hypertension, gender, and laboratory data. Our results show that the combination of multimodal features can increase the AUC by up to 5%, 7%, and 8% in the detection of AMD, DR, and glaucoma respectively. Marked improvement was achieved when laboratory results were combined with retinal image features.

  7. Pediatric Eye Screening Instrumentation

    NASA Astrophysics Data System (ADS)

    Chen, Ying-Ling; Lewis, J. W. L.

    2001-11-01

    Computational evaluations are presented for binocular eye screening using the off-axis digital retinascope. The retinascope, such as the iScreen digital screening system, has been employed to perform pediatric binocular screening using a flash lamp and single-shot camera recording. The digital images are transferred electronically to a reading center for analysis. The method has been shown to detect refractive error, amblyopia, anisocoria, and ptosis. This computational work improves the performance of the system and forms the basis for automated data analysis. For this purpose, variouis published eye models are evaluated with simulated retinascope images. Two to ten million rays are traced in each image calculation. The poster will present the simulation results for a range of eye conditions of refractive error of -20 to +20 diopters with 0.5- to-1 diopter resolution, pupil size of 3 to 8 mm diameter (1-mm increment), and staring angle of 2 to 12 degree (2-degree increment). The variation of the results with the system conditions such as the off-axis distance of light source and the shutter size of camera are also evaluated. The quantitative analysis for each eye’s and system’s condition is then performed to obtain parameters for automatic reading. The summary of the system performance is given and performance-enhancement design modifications are presented.

  8. Schizophrenia and the eye

    PubMed Central

    Silverstein, Steven M.; Rosen, Richard

    2015-01-01

    Although visual processing impairments are common in schizophrenia, it is not clear to what extent these originate in the eye vs. the brain. This review highlights potential contributions, from the retina and other structures of the eye, tovisual processing impairments in schizophrenia and high-risk states. A second goal is to evaluate the status of retinal abnormalities as biomarkers for schizophrenia. The review was motivated by known retinal changes in other disorders (e.g., Parkinson's disease, multiple sclerosis), and their relationships to perceptual and cognitive impairments, and disease progression therein. The evidence reviewed suggests two major conclusions. One is that there are multiple structural and functional disturbances of the eye in schizophrenia, all of which could be factors in the visual disturbances of patients. These include retinal venule widening, retinal nerve fiber layer thinning, dopaminergic abnormalities, abnormal ouput of retinal cells as measured by electroretinography (ERG), maculopathies and retinopathies, cataracts, poor acuity, and strabismus. Some of these are likely to be illness-related, whereas others may be due to medication or comorbid conditions. The second conclusion is that certain retinal findings can serve as biomarkers of neural pathology, and disease progression, in schizophrenia. The strongest evidence for this to date involves findings of widened retinal venules, thinning of the retinal nerve fiber layer, and abnormal ERG amplitudes. These data suggest that a greater understanding of the contribution of retinal and other ocular pathology to the visual and cognitive disturbances of schizophrenia is warranted, and that retinal changes have untapped clinical utility. PMID:26345525

  9. Eye preferences in captive chimpanzees.

    PubMed

    Braccini, Stephanie N; Lambeth, Susan P; Schapiro, Steven J; Fitch, W Tecumseh

    2012-09-01

    Over the last century, the issue of brain lateralization in primates has been extensively investigated and debated, yet no previous study has reported eye preference in great apes. This study examined eye preference in 45 captive chimpanzees (Pan troglodytes) in response to various stimuli. Eye preference was assessed when animals looked through a hole that only accommodated one eye at an empty box, a mirror, a picture of a dog, a rubber snake, food biscuits, bananas, a rubber duck, and a video camera. Main effects of stimulus type were found for direction of eye preference, number of looks, and looking duration, but not for strength of eye preference. A left-eye bias was found for viewing the rubber snake and a right-eye bias was found for viewing the bananas, supporting theories that emotional valence may affect lateralized behaviors. In addition, a significant shift in eye preference took place from the initial look to subsequent looks when viewing the snake. These results are not consistent with previous reports of human eye preference and may reflect lateralization differences for emotional processing. No relationship between eye preference and previously recorded hand preference was found. PMID:22733385

  10. Pioneers of eye movement research.

    PubMed

    Wade, Nicholas J

    2010-01-01

    Recent advances in the technology affording eye movement recordings carry the risk of neglecting past achievements. Without the assistance of this modern armoury, great strides were made in describing the ways the eyes move. For Aristotle the fundamental features of eye movements were binocular, and he described the combined functions of the eyes. This was later given support using simple procedures like placing a finger over the eyelid of the closed eye and culminated in Hering's law of equal innervation. However, the overriding concern in the 19th century was with eye position rather than eye movements. Appreciating discontinuities of eye movements arose from studies of vertigo. The characteristics of nystagmus were recorded before those of saccades and fixations. Eye movements during reading were described by Hering and by Lamare in 1879; both used similar techniques of listening to sounds made during contractions of the extraocular muscles. Photographic records of eye movements during reading were made by Dodge early in the 20th century, and this stimulated research using a wider array of patterns. In the mid-20th century attention shifted to the stability of the eyes during fixation, with the emphasis on involuntary movements. The contributions of pioneers from Aristotle to Yarbus are outlined.

  11. Pioneers of eye movement research

    PubMed Central

    Wade, Nicholas J

    2010-01-01

    Recent advances in the technology affording eye movement recordings carry the risk of neglecting past achievements. Without the assistance of this modern armoury, great strides were made in describing the ways the eyes move. For Aristotle the fundamental features of eye movements were binocular, and he described the combined functions of the eyes. This was later given support using simple procedures like placing a finger over the eyelid of the closed eye and culminated in Hering's law of equal innervation. However, the overriding concern in the 19th century was with eye position rather than eye movements. Appreciating discontinuities of eye movements arose from studies of vertigo. The characteristics of nystagmus were recorded before those of saccades and fixations. Eye movements during reading were described by Hering and by Lamare in 1879; both used similar techniques of listening to sounds made during contractions of the extraocular muscles. Photographic records of eye movements during reading were made by Dodge early in the 20th century, and this stimulated research using a wider array of patterns. In the mid-20th century attention shifted to the stability of the eyes during fixation, with the emphasis on involuntary movements. The contributions of pioneers from Aristotle to Yarbus are outlined. PMID:23396982

  12. Adaptive Optics for the Human Eye

    NASA Astrophysics Data System (ADS)

    Williams, D. R.

    2000-05-01

    Adaptive optics can extend not only the resolution of ground-based telescopes, but also the human eye. Both static and dynamic aberrations in the cornea and lens of the normal eye limit its optical quality. Though it is possible to correct defocus and astigmatism with spectacle lenses, higher order aberrations remain. These aberrations blur vision and prevent us from seeing at the fundamental limits set by the retina and brain. They also limit the resolution of cameras to image the living retina, cameras that are a critical for the diagnosis and treatment of retinal disease. I will describe an adaptive optics system that measures the wave aberration of the eye in real time and compensates for it with a deformable mirror, endowing the human eye with unprecedented optical quality. This instrument provides fresh insight into the ultimate limits on human visual acuity, reveals for the first time images of the retinal cone mosaic responsible for color vision, and points the way to contact lenses and laser surgical methods that could enhance vision beyond what is currently possible today. Supported by the NSF Science and Technology Center for Adaptive Optics, the National Eye Institute, and Bausch and Lomb, Inc.

  13. Eye model for the ground squirrel

    NASA Astrophysics Data System (ADS)

    Sussman, Dafna; Chou, B. Ralph; Lakshminarayanan, Vasudevan

    2011-11-01

    This paper presents an anatomically-correct eye model for the ground squirrel, a diurnal, highly-developed mammal with high visual acuity. This model can assist in understanding the relationship between ocular structural development and its corresponding function. The eye model is constructed based on anatomical measurements of thicknesses and indices of refraction of the various ocular media. The model then derives the gradient index distribution of the crystalline lens using a ray tracing method with a Monte Carlo optimization. Results indicate a diffraction-limited ocular behaviour, implying the visual acuity of the ground squirrel is more likely to be limited by photoreceptor density and diffraction effects, than by ocular geometry.

  14. Dry eye, blepharitis and chronic eye irritation: divide and conquer.

    PubMed

    Gilbard, J P

    1999-01-01

    Dry eye and posterior blepharitis are the two most common causes for chronic eye irritation. Dry eye is caused by loss of water from the tear film resulting from either decreased tear production or increased tear film evaporation. The resultant increase in tear film osmolarity causes the changes on the eye surface responsible for the symptoms of dry eye. Posterior blepharitis causes eye irritation from inflammation, and leads to the development of meibomian gland dysfunction. The patient history is a powerful tool in narrowing the differential diagnosis of chronic eye irritation or even establishing the diagnosis. The exam adds power to the history, and sorts out the mechanisms causing dry eye symptoms. The primary goal of dry eye treatment is to lower elevated tear film osmolarity. This can be achieved with TheraTears treatment, either with or without punctal plugs. The primary goal of meibomitis treatment is to reduce inflammation. This can be achieved by hot compresses and lid massage and, when necessary, systemic treatment with low dose doxycycline. By determining the cause or causes of chronic eye irritation, effective treatments can be employed.

  15. Increasing Accessibility to the Blind of Virtual Environments, Using a Virtual Mobility Aid Based On the "EyeCane": Feasibility Study

    PubMed Central

    Maidenbaum, Shachar; Levy-Tzedek, Shelly; Chebat, Daniel-Robert; Amedi, Amir

    2013-01-01

    Virtual worlds and environments are becoming an increasingly central part of our lives, yet they are still far from accessible to the blind. This is especially unfortunate as such environments hold great potential for them for uses such as social interaction, online education and especially for use with familiarizing the visually impaired user with a real environment virtually from the comfort and safety of his own home before visiting it in the real world. We have implemented a simple algorithm to improve this situation using single-point depth information, enabling the blind to use a virtual cane, modeled on the “EyeCane” electronic travel aid, within any virtual environment with minimal pre-processing. Use of the Virtual-EyeCane, enables this experience to potentially be later used in real world environments with identical stimuli to those from the virtual environment. We show the fast-learned practical use of this algorithm for navigation in simple environments. PMID:23977316

  16. Increasing accessibility to the blind of virtual environments, using a virtual mobility aid based on the "EyeCane": feasibility study.

    PubMed

    Maidenbaum, Shachar; Levy-Tzedek, Shelly; Chebat, Daniel-Robert; Amedi, Amir

    2013-01-01

    Virtual worlds and environments are becoming an increasingly central part of our lives, yet they are still far from accessible to the blind. This is especially unfortunate as such environments hold great potential for them for uses such as social interaction, online education and especially for use with familiarizing the visually impaired user with a real environment virtually from the comfort and safety of his own home before visiting it in the real world. We have implemented a simple algorithm to improve this situation using single-point depth information, enabling the blind to use a virtual cane, modeled on the "EyeCane" electronic travel aid, within any virtual environment with minimal pre-processing. Use of the Virtual-EyeCane, enables this experience to potentially be later used in real world environments with identical stimuli to those from the virtual environment. We show the fast-learned practical use of this algorithm for navigation in simple environments.

  17. Cortexin diffusion in human eye sclera

    SciTech Connect

    Genina, Elina A; Bashkatov, A N; Tuchin, Valerii V; Ghosn, M G; Larin, Kirill V; Kamenskikh, T G

    2011-05-31

    Investigation of the diffusion of cytamines, a typical representative of which is cortexin, is important for evaluating the drug dose, necessary to provide sufficient concentration of the preparation in the inner tissues of the eye. In the present paper, the cortexin diffusion rate in the eye sclera is measured using the methods of optical coherence tomography (OCT) and reflectance spectroscopy. The technique for determining the diffusion coefficient is based on the registration of temporal dependence of the eye sclera scattering parameters caused by partial replacement of interstitial fluid with the aqueous cortexin solution, which reduces the level of the OCT signal and decreases the reflectance of the sclera. The values of the cortexin diffusion coefficient obtained using two independent optical methods are in good agreement. (optical technologies in biophysics and medicine)

  18. Optical eye simulator for laser dazzle events.

    PubMed

    Coelho, João M P; Freitas, José; Williamson, Craig A

    2016-03-20

    An optical simulator of the human eye and its application to laser dazzle events are presented. The simulator combines optical design software (ZEMAX) with a scientific programming language (MATLAB) and allows the user to implement and analyze a dazzle scenario using practical, real-world parameters. Contrary to conventional analytical glare analysis, this work uses ray tracing and the scattering model and parameters for each optical element of the eye. The theoretical background of each such element is presented in relation to the model. The overall simulator's calibration, validation, and performance analysis are achieved by comparison with a simpler model based uponCIE disability glare data. Results demonstrate that this kind of advanced optical eye simulation can be used to represent laser dazzle and has the potential to extend the range of applicability of analytical models. PMID:27140558

  19. Inherited eye disease: cause and late effect.

    PubMed

    Manson, Forbes D C; Trump, Dorothy; Read, Andrew P; Black, Graeme C M

    2005-10-01

    Molecular genetics has provided relatively few insights into late-onset eye disorders, but epidemiological data indicate that genetic factors are important in some late-onset eye disorders that cause major health burdens. Much clinical genetic research is based on the belief that developmental and late-onset disorders are not necessarily the result of defects in different genes, but are often caused by different mutations in the same collection of genes. Thus, mutations that either abolish or radically change gene function might cause early-onset disorders, whereas more-subtle changes in gene expression might underlie late-onset diseases. We present arguments and examples that indicate that this principle might be a fruitful guide to investigating the causes of late-onset eye disorders. PMID:16153893

  20. Using novel in vitro NociOcular assay based on TRPV1 channel activation for prediction of eye sting potential of baby shampoos.

    PubMed

    Forsby, Anna; Norman, Kimberly G; El Andaloussi-Lilja, Johanna; Lundqvist, Jessica; Walczak, Vincent; Curren, Rodger; Martin, Katharine; Tierney, Neena K

    2012-10-01

    The transient receptor potential vanilloid type 1 (TRPV1) channel is one of the most well-characterized pain-inducing receptors. The purpose of this study was to predict human eye stinging of 19 baby bath and shampoo formulations by studying TRPV1 activity, as measured by increase in intracellular free Ca(2+). The NociOcular test, a novel recombinant neuronal in vitro model with high expression of functional TRPV1 channels, was used to test formulations containing a variety of surfactants, preservatives, and fragrances. TRPV1-specific Ca(2+) influx was abolished when the TRPV1 channel antagonist capsazepine was applied to the cells prior to shampoo samples. The positive control, an adult shampoo that contains cocamide monoethanolamine (CMEA), a known stinging ingredient, was the most active sample tested in the NociOcular test. The negative control, a marketed baby shampoo, was negative in the NociOcular and human tests. Seven of the formulations induced stinging in the human test, and of those six were positive in the NociOcular test. Twelve formulations were classified as nonstinging in the human test, and of those ten were negative in the NociOcular test. There was no correlation between the clinical stinging results for the baby formulations and the data generated from other in vitro eye irritation assays (cytosensor microphysiometer, neutral red uptake, EpiOcular, transepithelial permeability). Our data support that the TRPV1 channel is a principal mediator of eye-stinging sensation induced by baby bath and shampoo formulations and that the NociOcular test may be a valuable in vitro tool to predict human eye-stinging sensation.

  1. Compound eye formation in the termite Incisitermes minor (Isoptera: Kalotermitidae).

    PubMed

    Rose, Taylor C; Ediger, Emily F; Lehman-Schletewitz, Joy; McClane, Nathan W; Schweigert, Kristen C; Alzweideh, Saif; Wadsworth, Lauren; Husseneder, Claudia; Morris, Joshua W; Ziesmann, Jurgen

    2015-07-01

    The postembryonic development and caste differentiation patterns of lower termites have been described multiple times in a variety of different species. However, most of these studies focused on gross ontogeny, without carefully describing the maturation of any particular organ or organ system. The few studies that have attempted to correlate caste development and organ differentiation have produced somewhat inconsistent results, especially in the area of eye formation. Therefore, in order to help further elucidate the relationship between eye formation and postembryonic differentiation in lower termites, we studied eye development in the termite, Incisitermes minor (Hagen). Eye formation in I. minor began in the earliest larvae, with only an eye primordium. However, in all later larval stages, characteristic eye structures were observed and were shown to progressively differentiate through larval and nymphal stages. Curiously, pigmentation began with three to eight groups of cells in early larvae and the number of these pigmented groups increased along the developmental time course. Ultimately, a uniformly pigmented eye area was formed by the early nymphal stage. The overall eye area also gradually increased along with normal caste development, but the characteristic lenses seen in a prototypical insect compound eye did not completely form until after the final nymphal stage. Electrophysiological measurements provided clear evidence that eyes were indeed functional at all stages of development where pigment was present. Based upon this data, the eye development pattern in I. minor appeared to follow a divergent pathway from holometabolous insects and an intermediate pathway between typical hemimetabolous eye development and the heterochronic shift observed in other termite species.

  2. Eye Movement Correlates of Acquired Central Dyslexia

    ERIC Educational Resources Information Center

    Schattka, Kerstin I.; Radach, Ralph; Huber, Walter

    2010-01-01

    Based on recent progress in theory and measurement techniques, the analysis of eye movements has become one of the major methodological tools in experimental reading research. Our work uses this approach to advance the understanding of impaired information processing in acquired central dyslexia of stroke patients with aphasia. Up to now there has…

  3. "Dry Eye" Is the Wrong Diagnosis for Millions.

    PubMed

    Korb, Donald R; Blackie, Caroline A

    2015-09-01

    The clinical perspective that dry eye is, at best, an incomplete diagnosis and the benefit of an etiology-based approach to dry eye are presented. To provide context for this perspective, the historical and current definition of dry eye is reviewed. The paradigm shift introduced by the Meibomian Gland Dysfunction (MGD) Workshop, that MGD is likely the leading cause of dry eye, is discussed in combination with the advancements in the diagnosis and treatment of MGD. To facilitate discussion on the benefit of an etiology-based approach, a retrospective observational analysis was performed on deidentified data from eligible, fully consented, refractory dry eye patients, where conventional sequelae-based dry eye treatment had failed. In this refractory population, the diagnosis of MGD, which directed treatment to evacuating gland obstructions and rehabilitating gland function, was successful. The clinical perspective that "dry eye" is the wrong diagnosis for millions is provocative. However, the MGD-first approach has the potential to revolutionize the timing of diagnosis and the choice of frontline therapy in most patients with dry eye. Additionally, the ability to screen for MGD in its earliest stages, during routine care, expands the scope of clinical practice to include early intervention. For most patients, we are no longer constrained to delay diagnosis until the tear film has decompensated and the cascade of inflammation has ensued. We do not have to wait for our patients to tell us there is a problem.

  4. "Dry Eye" Is the Wrong Diagnosis for Millions.

    PubMed

    Korb, Donald R; Blackie, Caroline A

    2015-09-01

    The clinical perspective that dry eye is, at best, an incomplete diagnosis and the benefit of an etiology-based approach to dry eye are presented. To provide context for this perspective, the historical and current definition of dry eye is reviewed. The paradigm shift introduced by the Meibomian Gland Dysfunction (MGD) Workshop, that MGD is likely the leading cause of dry eye, is discussed in combination with the advancements in the diagnosis and treatment of MGD. To facilitate discussion on the benefit of an etiology-based approach, a retrospective observational analysis was performed on deidentified data from eligible, fully consented, refractory dry eye patients, where conventional sequelae-based dry eye treatment had failed. In this refractory population, the diagnosis of MGD, which directed treatment to evacuating gland obstructions and rehabilitating gland function, was successful. The clinical perspective that "dry eye" is the wrong diagnosis for millions is provocative. However, the MGD-first approach has the potential to revolutionize the timing of diagnosis and the choice of frontline therapy in most patients with dry eye. Additionally, the ability to screen for MGD in its earliest stages, during routine care, expands the scope of clinical practice to include early intervention. For most patients, we are no longer constrained to delay diagnosis until the tear film has decompensated and the cascade of inflammation has ensued. We do not have to wait for our patients to tell us there is a problem. PMID:26204473

  5. Saccadic eye movements and eye-head coordination in children.

    PubMed

    Funk, C J; Anderson, M E

    1977-04-01

    The eye and head movements of nine children, ages 6 through 10, were measured in order to establish quantitative characteristics of eye movements and eye-head corrdination patterns of children with normal vision and reading levels. The relationship between saccade amplitude and duration was linear, but the slope of this relationship indicated that saccades in children may have higher velocities than they do in adults. One of three temporal patterns of head and saccadic eye movement occurred during shifts of gaze to visual targets, depending on the temporal and spatial predictability of the target. It is suggested that quantitative measurements such as these could be used to examine developmental characteristics of eye and eye-head movement control.

  6. Genetic analyses of the human eye colours using a novel objective method for eye colour classification.

    PubMed

    Andersen, Jeppe D; Johansen, Peter; Harder, Stine; Christoffersen, Susanne R; Delgado, Mikaela C; Henriksen, Sarah T; Nielsen, Mette M; Sørensen, Erik; Ullum, Henrik; Hansen, Thomas; Dahl, Anders L; Paulsen, Rasmus R; Børsting, Claus; Morling, Niels

    2013-09-01

    In this study, we present a new objective method for measuring the eye colour on a continuous scale that allows researchers to associate genetic markers with different shades of eye colour. With the use of the custom designed software Digital Iris Analysis Tool (DIAT), the iris was automatically identified and extracted from high resolution digital images. DIAT was made user friendly with a graphical user interface. The software counted the number of blue and brown pixels in the iris image and calculated a Pixel Index of the Eye (PIE-score) that described the eye colour quantitatively. The PIE-score ranged from -1 to 1 (brown to blue). The software eliminated the need for user based interpretation and qualitative eye colour categories. In 94% (570) of 605 analyzed eye images, the iris region was successfully extracted and a PIE-score was calculated. A very high correlation between the PIE-score and the human perception of eye colour was observed. The correlations between the PIE-scores and the six IrisPlex SNPs (HERC2 rs12913832, OCA2 rs1800407, SLC24A4 rs12896399, TYR rs1393350, SLC45A2 rs16891982 and IRF4 rs12203592) were analyzed in 570 individuals. Significant differences (p<10(-6)) in the PIE-scores of the individuals typed as HERC2 rs12913832 G (PIE=0.99) and rs12913832 GA (PIE=-0.71) or A (PIE=-0.87) were observed. We adjusted for the effect of HERC2 rs12913832 and showed that the quantitative PIE-scores were significantly associated with SNPs with minor effects (OCA2 rs1800407, SLC24A4 rs12896399 and TYR rs1393350) on the eye colour. We evaluated the two published prediction models for eye colour (IrisPlex [1] and Snipper[2]) and compared the predictions with the PIE-scores. We found good concordance with the prediction from individuals typed as HERC2 rs12913832 G. However, both methods had difficulties in categorizing individuals typed as HERC2 rs12913832 GA because of the large variation in eye colour in HERC2 rs12913832 GA individuals. With the use of

  7. Eyes Wide Shut: Amygdala Mediates Eyes-Closed Effect on Emotional Experience with Music

    PubMed Central

    Lerner, Yulia; Papo, David; Zhdanov, Andrey; Belozersky, Libi; Hendler, Talma

    2009-01-01

    The perceived emotional value of stimuli and, as a consequence the subjective emotional experience with them, can be affected by context-dependent styles of processing. Therefore, the investigation of the neural correlates of emotional experience requires accounting for such a variable, a matter of an experimental challenge. Closing the eyes affects the style of attending to auditory stimuli by modifying the perceptual relationship with the environment without changing the stimulus itself. In the current study, we used fMRI to characterize the neural mediators of such modification on the experience of emotionality in music. We assumed that closed eyes position will reveal interplay between different levels of neural processing of emotions. More specifically, we focused on the amygdala as a central node of the limbic system and on its co-activation with the Locus Ceruleus (LC) and Ventral Prefrontal Cortex (VPFC); regions involved in processing of, respectively, ‘low’, visceral-, and ‘high’, cognitive-related, values of emotional stimuli. Fifteen healthy subjects listened to negative and neutral music excerpts with eyes closed or open. As expected, behavioral results showed that closing the eyes while listening to emotional music resulted in enhanced rating of emotionality, specifically of negative music. In correspondence, fMRI results showed greater activation in the amygdala when subjects listened to the emotional music with eyes closed relative to eyes open. More so, by using voxel-based correlation and a dynamic causal model analyses we demonstrated that increased amygdala activation to negative music with eyes closed led to increased activations in the LC and VPFC. This finding supports a system-based model of perceived emotionality in which the amygdala has a central role in mediating the effect of context-based processing style by recruiting neural operations involved in both visceral (i.e. ‘low’) and cognitive (i.e. ‘high’) related processes

  8. Electroanalytical and naked eye determination of Cu(2+) ion in various environmental samples using 5-amino-1,3,4-thiadiazole-2-thiol based Schiff bases.

    PubMed

    Bandi, Koteswara Rao; Singh, Ashok Kumar; Upadhyay, Anjali

    2014-01-01

    Novel polydentate Schiff bases 4-(5-mercapto-1,3,4-thiadiazol-2-ylimino)pentan-2-one (S1) and (2-(indol-3-yl)vinyl)-1,3,4-thiadiazole-2-thiol (S2) were synthesized and explored as Cu(2+) selective polymeric membrane electrodes (PME) using different plasticizers and anionic excluders. The potentiometric data revealed that the PME having the membrane composition (S2: NaTPB: TBP: PVC as 4: 2: 58: 36 (w/w; mg)) is shown to have good results. Thus the coated graphite electrode (CGE) with the same composition as the best PME was also fabricated and investigated as Cu(2+) selective electrode. It was found that CGE showed better response characteristics than PME with respect to low detection limit (1.2×10(-8)molL(-1)), near Nernstian slope (29.8±0.4mV decade(-1) of activity), wide working concentration range (6.4×10(-8)-1.0×10(-1)molL(-1)), long shelf life (90days) and fast response time (9s). The CGE was used successfully as an indicator electrode for the potentiometric determination of Cu(2+) ion against EDTA and also used to quantify Cu(2+) ion in soil, water, medicinal plants, vegetables and edible oil samples. The Schiff base S2 is used as chemosensor for the selective determination of Cu(2+) ion.

  9. Optics of arthropod compound eye.

    PubMed

    Shaw, S R

    1969-07-01

    The extent to which light can escape from one ommatidium into its neighbors in the compound eye has been examined by recording from single receptors during stimulation of single facets. In the "apposition" eye of the drone honeybee and locust, optical interaction is extremely small. In the "superposition" eye of the crayfish, more than half the light captured by the average cell gets in through neighboring facets, even when screening pigments are in the fully lightadapted position.

  10. Automatic dry eye detection.

    PubMed

    Yedidya, Tamir; Hartley, Richard; Guillon, Jean-Pierre; Kanagasingam, Yogesan

    2007-01-01

    Dry Eye Syndrome is a common disease in the western world, with effects from uncomfortable itchiness to permanent damage to the ocular surface. Nevertheless, there is still no objective test that provides reliable results. We have developed a new method for the automated detection of dry areas in videos taken after instilling fluorescein in the tear film. The method consists of a multi-step algorithm to first locate the iris in each image, then align the images and finally analyze the aligned sequence in order to find the regions of interest. Since the fluorescein spreads on the ocular surface of the eye the edges of the iris are fuzzy making the detection of the iris challenging. We use RANSAC to first detect the upper and lower eyelids and then the iris. Then we align the images by finding differences in intensities at different scales and using a least squares optimization method (Levenberg-Marquardt), to overcome the movement of the iris and the camera. The method has been tested on videos taken from different patients. It is demonstrated to find the dry areas accurately and to provide a measure of the extent of the disease. PMID:18051131

  11. Laser eye injuries.

    PubMed

    Barkana, Y; Belkin, M

    2000-01-01

    Laser instruments are used in many spheres of human activity, including medicine, industry, laboratory research, entertainment, and, notably, the military. This widespread use of lasers has resulted in many accidental injuries. Injuries are almost always retinal, because of the concentration of visible and near-infrared radiation on the retina. The retina is therefore the body tissue most vulnerable to laser radiation. The nature and severity of this type of retinal injury is determined by multiple laser-related and eye-related factors, the most important being the duration and amount of energy delivered and the retinal location of the lesion. The clinical course of significant retinal laser injuries is characterized by sudden loss of vision, often followed by marked improvement over a few weeks, and occasionally severe late complications. Medical and surgical treatment is limited. Laser devices hazardous to the human eye are currently in widespread use by armed forces. Furthermore, lasers may be employed specifically for visual incapacitation on future battlefields. Adherence to safety practices effectively prevents accidental laser-induced ocular injuries. However, there is no practical way to prevent injuries that are maliciously inflicted, as expected from laser weapons.

  12. Eye Surgery Light

    NASA Technical Reports Server (NTRS)

    1978-01-01

    During eye surgery, the surgeon uses an illuminating instrument called an opthalmoscope for close examination of the retina or the interior of the eye. Ordinarily, electric power for the head-mounted light is supplied through a cord from an overhead swivel arm or a floor pedestal. Within limits of cord length and swivel arm movement, the surgeon has considerable freedom of motion. But when more than one opthalmoscope is involved, tangling and interference of the power cords becomes a problem. St. Luke's Hospital, Cleveland, Ohio asked Lewis Research Center for assistance in finding a solution. Lewis responded with a battery-powered system that totally frees the surgeon of attached cords and swivels. Borrowing from space technology, Lewis used small, lightweight nickel-cadmium batteries that can deliver high intensity light for an hour and can be recharged overnight. The Opthalmoscope Powerpack consists of eight batteries in three containers affixed to a webbed belt, and a novel on-off switch equipped with a springloaded plexiglass "flapper." The belt pack is worn underneath the surgical gown and the flapper permits the doctor to activate the switch by elbow pressure. Lewis built five units and they have been in service at St. Luke's Hospital for a year. Used for routine examinations as well as for surgery, they have demonstrated excellent reliability.

  13. Eye Surgery Light

    NASA Technical Reports Server (NTRS)

    1978-01-01

    During eye surgery, the surgeon uses an illuminating instrument called an opthalmoscope for close examination of the retina or the interior of the eye. Ordinarily, electric power for the head-mounted light is supplied through a cord from an overhead swivel arm or a floor pedestal. Within limits of cord length and swivel arm movement, the surgeon has considerable freedom of motion. But when more than one opthalmoscope is involved, tangling and interference of the power cords becomes a problem. St. Luke's Hospital, Cleveland, Ohio asked Lewis Research Center for assistance in finding a solution. Lewis responded with a battery-powered system that totally frees the surgeon of attached cords and swivels. Borrowing from space technology, Lewis used small, lightweight nickel-cadmium batteries that can deliver high intensity light for an hour and can be recharged overnight. The Opthalmoscope Powerpack consists of eight batteries in three containers affixed to a webbed belt, and a novel on-off switch equipped with a spring-loaded plexiglass 'flapper.' The belt pack is worn underneath the surgical gown and the flapper permits the doctor to activate the switch by elbow pressure. Lewis built five units and they have been in service at St. Luke's Hospital for a year. Used for routine examinations as well as for surgery, they have demonstrated excellent reliability.

  14. Aging and dry eye disease.

    PubMed

    Ding, Juan; Sullivan, David A

    2012-07-01

    Dry eye disease is a prevalent eye disorder that in particular affects the elderly population. One of the major causes of dry eye, meibomian gland dysfunction (MGD), shows increased prevalence with aging. MGD is caused by hyperkeratinization of the ductal epithelium of meibomian gland and reduced quantity and/or quality of meibum, the holocrine product that stabilizes and prevents the evaporation of the tear film. Of note, retinoids which are used in current anti-aging cosmetics may promote the development of MGD and dry eye disease. In this review, we will discuss the possible mechanisms of age-related MGD.

  15. Aging and dry eye disease

    PubMed Central

    Ding, Juan; Sullivan, David A.

    2012-01-01

    Dry eye disease is a prevalent eye disorder that in particular affects the elderly population. One of the major causes of dry eye, meibomian gland dysfunction (MGD), shows increased prevalence with aging. MGD is caused by hyperkeratinization of the ductal epithelium of meibomian gland and reduced quantity and/or quality of meibum, the holocrine product that stabilizes and prevents the evaporation of the tear film. Of note, retinoids which are used in current anti-aging cosmetics may promote the development of MGD and dry eye disease. In this review, we will discuss the possible mechanisms of age-related MGD. PMID:22569356

  16. Perceived visual motion as effective stimulus to pursuit eye movement system

    NASA Technical Reports Server (NTRS)

    Yasui, S.; Young, L. R.

    1975-01-01

    Human eye tracking of a foveal afterimage during angular head oscillation in the dark produced smooth eye movements exceeding those for normal vestibular nystagmus, and a reduction in the frequency of the fast phase component of nystagmus eye movements. These results may support a closed loop extension of the corollary discharge theory, with oculomotor commands based on perceived object velocity.

  17. Protect Their Eyes: An Eye Safety Guide for the Classroom.

    ERIC Educational Resources Information Center

    Ohio Society to Prevent Blindness, Columbus.

    This guide provides information on eye safety and aids educators, administrators, and supervisors in the development and implementation of eye safety programs. The American National Standards Institute (AMSI) requirements for both street and safety glasses; essential eyewear for safety in hazardous areas; the National Society to Prevent…

  18. Alternative methods for the replacement of eye irritation testing.

    PubMed

    Lotz, Christian; Schmid, Freia F; Rossi, Angela; Kurdyn, Szymon; Kampik, Daniel; De Wever, Bart; Walles, Heike; Groeber, Florian K

    2016-01-01

    In the last decades significant regulatory attempts were made to replace, refine and reduce animal testing to assess the risk of consumer products for the human eye. As the original in vivo Draize eye test has been criticized for limited predictivity, costs and ethical issues, several animal-free test methods have been developed to categorize substances according to the global harmonized system (GHS) for eye irritation.This review summarizes the progress of alternative test methods for the assessment of eye irritation. Based on the corneal anatomy and the current knowledge of the mechanisms causing eye irritation, different ex vivo and in vitro methods will be presented and discussed in regard of possible limitations and their status of regulatory acceptance. In addition to established in vitro models, this review will also highlight emerging, full thickness cornea models that might be applicable to predict all GHS categories.

  19. Trajectory interpretation by supplementary eye field neurons during ocular baseball.

    PubMed

    Kim, Yong-Guk; Badler, Jeremy B; Heinen, Stephen J

    2005-08-01

    Good performance in the sport of baseball shows that humans can determine the trajectory of a moving object and act on it under the constraint of a rule. We report here on neuronal activity in the supplementary eye field (SEF) of monkeys performing an eye movement task inspired by baseball. In "ocular baseball," a pursuit eye movement to a target is executed or withheld based on the target's trajectory. We found that a subset of neurons in the SEF interpreted the trajectory according to the task rule. Other neurons specified at a later time the command to pursue the target with the eyes. The results suggest that the SEF can interpret sensory signals about target motion in the context of a rule to guide voluntary eye movement initiation.

  20. Multimodal emotion recognition using EEG and eye tracking data.

    PubMed

    Zheng, Wei-Long; Dong, Bo-Nan; Lu, Bao-Liang

    2014-01-01

    This paper presents a new emotion recognition method which combines electroencephalograph (EEG) signals and pupillary response collected from eye tracker. We select 15 emotional film clips of 3 categories (positive, neutral and negative). The EEG signals and eye tracking data of five participants are recorded, simultaneously, while watching these videos. We extract emotion-relevant features from EEG signals and eye tracing data of 12 experiments and build a fusion model to improve the performance of emotion recognition. The best average accuracies based on EEG signals and eye tracking data are 71.77% and 58.90%, respectively. We also achieve average accuracies of 73.59% and 72.98% for feature level fusion strategy and decision level fusion strategy, respectively. These results show that both feature level fusion and decision level fusion combining EEG signals and eye tracking data can improve the performance of emotion recognition model. PMID:25571125

  1. Gaze Estimation From Eye Appearance: A Head Pose-Free Method via Eye Image Synthesis.

    PubMed

    Lu, Feng; Sugano, Yusuke; Okabe, Takahiro; Sato, Yoichi

    2015-11-01

    In this paper, we address the problem of free head motion in appearance-based gaze estimation. This problem remains challenging because head motion changes eye appearance significantly, and thus, training images captured for an original head pose cannot handle test images captured for other head poses. To overcome this difficulty, we propose a novel gaze estimation method that handles free head motion via eye image synthesis based on a single camera. Compared with conventional fixed head pose methods with original training images, our method only captures four additional eye images under four reference head poses, and then, precisely synthesizes new training images for other unseen head poses in estimation. To this end, we propose a single-directional (SD) flow model to efficiently handle eye image variations due to head motion. We show how to estimate SD flows for reference head poses first, and then use them to produce new SD flows for training image synthesis. Finally, with synthetic training images, joint optimization is applied that simultaneously solves an eye image alignment and a gaze estimation. Evaluation of the method was conducted through experiments to assess its performance and demonstrate its effectiveness. PMID:26080385

  2. Gaze Estimation From Eye Appearance: A Head Pose-Free Method via Eye Image Synthesis.

    PubMed

    Lu, Feng; Sugano, Yusuke; Okabe, Takahiro; Sato, Yoichi

    2015-11-01

    In this paper, we address the problem of free head motion in appearance-based gaze estimation. This problem remains challenging because head motion changes eye appearance significantly, and thus, training images captured for an original head pose cannot handle test images captured for other head poses. To overcome this difficulty, we propose a novel gaze estimation method that handles free head motion via eye image synthesis based on a single camera. Compared with conventional fixed head pose methods with original training images, our method only captures four additional eye images under four reference head poses, and then, precisely synthesizes new training images for other unseen head poses in estimation. To this end, we propose a single-directional (SD) flow model to efficiently handle eye image variations due to head motion. We show how to estimate SD flows for reference head poses first, and then use them to produce new SD flows for training image synthesis. Finally, with synthetic training images, joint optimization is applied that simultaneously solves an eye image alignment and a gaze estimation. Evaluation of the method was conducted through experiments to assess its performance and demonstrate its effectiveness.

  3. Assessment of the eye irritation potential of chemicals: A comparison study between two test methods based on human 3D hemi-cornea models.

    PubMed

    Tandon, R; Bartok, M; Zorn-Kruppa, M; Brandner, J M; Gabel, D; Engelke, M

    2015-12-25

    We have recently developed two hemi-cornea models (Bartok et al., Toxicol in Vitro 29, 72, 2015; Zorn-Kruppa et al. PLoS One 9, e114181, 2014), which allow the correct prediction of eye irritation potential of chemicals according to the United Nations globally harmonized system of classification and labeling of chemicals (UN GHS). Both models comprise a multilayered epithelium and a stroma with embedded keratocytes in a collagenous matrix. These two models were compared, using a set of fourteen test chemicals. Their effects after 10 and 60 minutes (min) exposure were assessed from the quantification of cell viability using the MTT reduction assay. The first approach separately quantifies the damage inflicted to the epithelium and the stroma. The second approach quantifies the depth of injury by recording cell death as a function of depth. The classification obtained by the two models was compared to the Draize rabbit eye test and an ex vivo model using rabbit cornea (Jester et al. Toxicol in Vitro. 24, 597-604, 2010). With a 60 min exposure, both of our models are able to clearly differentiate UN GHS Category 1 and UN GHS Category 2 test chemicals.

  4. A novel approach to formulation factor of aceclofenac eye drops efficiency evaluation based on physicochemical characteristics of in vitro and in vivo permeation

    PubMed Central

    Dave, Vivek; Paliwal, Sarvesh

    2013-01-01

    The purpose of the present study was to evaluate aceclofenac eye drop through excised goat cornea. Raising pH of the formulation from 6.0 to 8.0, effect of different preservatives or effect of viscosity enhancer decreases apparent permeability coefficient. Topical ophthalmic NSAID are used to treat ocular surface and anterior segment inflammation as well as post operative management of pain and inflammation. Aceclofenac’s unique chemical structure makes it both a potent anti inflammatory drug and lipophilic molecule that penetrates ocular tissue, ensuring relief of pain in cataract and refractive surgery and corneal abrasion. The octanol/water partition coefficient of aceclofenac drug is 1.86 ± 0.75. Permeation characteristics of the drug were evaluated by putting 1 ml formulation on freshly excised goat cornea fixed between donor and receptor compartments of an all-glass modified Franz diffusion cell and measuring the drug permeated in the receptor by spectrophotometry at 275 nm, after 120 min. The results suggest that aceclofenac ophthalmic solution (pH 7) containing BAC provides increased in vitro ocular availability through goat corneas. The combination of methyl paraben and propyl paraben MP–PP preservative in aceclofenac ophthalmic eye drop 0.1% formulated in phosphate buffer increases transcorneal permeation. The developed formulations were evaluated for their pharmacodynamics in albino rabbits, by measuring in-vivo study and were compared to a marketed voltrane ophthalmic solution. PMID:25061410

  5. Role of the iridescent eye in stickleback female mate choice.

    PubMed

    Flamarique, Iñigo Novales; Bergstrom, Carolyn; Cheng, Christiana L; Reimchen, Thomas E

    2013-08-01

    Many vertebrates exhibit prominent body colours that are used in courtship and territorial communication. Some fishes also have an eye whose iris becomes iridescent during the mating season, as in the threespine stickleback. Behavioural studies in this species have focused on the redness of the throat/jaw as the primary determinant of female mate choice. Unlike the iridescent eye, however, the red throat/jaw is not present in all stickleback populations, suggesting that the colour of the eye may be equally important for female mate choice. Here, we used data on photoreceptors and environmental light to assess body conspicuousness and the colour contrast of courtship signals for stickleback populations living in a range of waters, from clear (mesotrophic) to red light shifted (dystrophic). This analysis indicated that the redness of the throat/jaw is expressed to enhance the contrast of the eye. To test the importance of eye colour as a courtship signal, we carried out mate choice experiments in which females were presented with identical videos of a courting male but for the colour of the eye and/or the throat/jaw. Females did not choose based on differences in throat/jaw redness between videos, but preferred males with the highest contrast between the eye and the throat/jaw. This result points to the blue iridescent eye as a primary courtship signal in stickleback female mate choice.

  6. Simultaneous Eye Tracking and Blink Detection with Interactive Particle Filters

    NASA Astrophysics Data System (ADS)

    Wu, Junwen; Trivedi, Mohan M.

    2007-12-01

    We present a system that simultaneously tracks eyes and detects eye blinks. Two interactive particle filters are used for this purpose, one for the closed eyes and the other one for the open eyes. Each particle filter is used to track the eye locations as well as the scales of the eye subjects. The set of particles that gives higher confidence is defined as the primary set and the other one is defined as the secondary set. The eye location is estimated by the primary particle filter, and whether the eye status is open or closed is also decided by the label of the primary particle filter. When a new frame comes, the secondary particle filter is reinitialized according to the estimates from the primary particle filter. We use autoregression models for describing the state transition and a classification-based model for measuring the observation. Tensor subspace analysis is used for feature extraction which is followed by a logistic regression model to give the posterior estimation. The performance is carefully evaluated from two aspects: the blink detection rate and the tracking accuracy. The blink detection rate is evaluated using videos from varying scenarios, and the tracking accuracy is given by comparing with the benchmark data obtained using the Vicon motion capturing system. The setup for obtaining benchmark data for tracking accuracy evaluation is presented and experimental results are shown. Extensive experimental evaluations validate the capability of the algorithm.

  7. Accurate eye center location through invariant isocentric patterns.

    PubMed

    Valenti, Roberto; Gevers, Theo

    2012-09-01

    Locating the center of the eyes allows for valuable information to be captured and used in a wide range of applications. Accurate eye center location can be determined using commercial eye-gaze trackers, but additional constraints and expensive hardware make these existing solutions unattractive and impossible to use on standard (i.e., visible wavelength), low-resolution images of eyes. Systems based solely on appearance are proposed in the literature, but their accuracy does not allow us to accurately locate and distinguish eye centers movements in these low-resolution settings. Our aim is to bridge this gap by locating the center of the eye within the area of the pupil on low-resolution images taken from a webcam or a similar device. The proposed method makes use of isophote properties to gain invariance to linear lighting changes (contrast and brightness), to achieve in-plane rotational invariance, and to keep low-computational costs. To further gain scale invariance, the approach is applied to a scale space pyramid. In this paper, we extensively test our approach for its robustness to changes in illumination, head pose, scale, occlusion, and eye rotation. We demonstrate that our system can achieve a significant improvement in accuracy over state-of-the-art techniques for eye center location in standard low-resolution imagery. PMID:22813958

  8. Wavefront Derived Refraction and Full Eye Biometry in Pseudophakic Eyes

    PubMed Central

    Mao, Xinjie; Banta, James T.; Ke, Bilian; Jiang, Hong; He, Jichang; Liu, Che; Wang, Jianhua

    2016-01-01

    Purpose To assess wavefront derived refraction and full eye biometry including ciliary muscle dimension and full eye axial geometry in pseudophakic eyes using spectral domain OCT equipped with a Shack-Hartmann wavefront sensor. Methods Twenty-eight adult subjects (32 pseudophakic eyes) having recently undergone cataract surgery were enrolled in this study. A custom system combining two optical coherence tomography systems with a Shack-Hartmann wavefront sensor was constructed to image and monitor changes in whole eye biometry, the ciliary muscle and ocular aberration in the pseudophakic eye. A Badal optical channel and a visual target aligning with the wavefront sensor were incorporated into the system for measuring the wavefront-derived refraction. The imaging acquisition was performed twice. The coefficients of repeatability (CoR) and intraclass correlation coefficient (ICC) were calculated. Results Images were acquired and processed successfully in all patients. No significant difference was detected between repeated measurements of ciliary muscle dimension, full-eye biometry or defocus aberration. The CoR of full-eye biometry ranged from 0.36% to 3.04% and the ICC ranged from 0.981 to 0.999. The CoR for ciliary muscle dimensions ranged from 12.2% to 41.6% and the ICC ranged from 0.767 to 0.919. The defocus aberrations of the two measurements were 0.443 ± 0.534 D and 0.447 ± 0.586 D and the ICC was 0.951. Conclusions The combined system is capable of measuring full eye biometry and refraction with good repeatability. The system is suitable for future investigation of pseudoaccommodation in the pseudophakic eye. PMID:27010674

  9. Computer Analysis of Eye Blood-Vessel Images

    NASA Technical Reports Server (NTRS)

    Wall, R. J.; White, B. S.

    1984-01-01

    Technique rapidly diagnoses diabetes mellitus. Photographs of "whites" of patients' eyes scanned by computerized image analyzer programmed to quantify density of small blood vessels in conjuctiva. Comparison with data base of known normal and diabetic patients facilitates rapid diagnosis.

  10. Microoptical telescope compound eye.

    PubMed

    Duparré, Jacques; Schreiber, Peter; Matthes, André; Pshenay-Severin, Ekaterina; Bräuer, Andreas; Tünnermann, Andreas; Völkel, Reinhard; Eisner, Martin; Scharf, Toralf

    2005-02-01

    A new optical concept for compact digital image acquisition devices with large field of view is developed and proofed experimentally. Archetypes for the imaging system are compound eyes of small insects and the Gabor-Superlens. A paraxial 3x3 matrix formalism is used to describe the telescope arrangement of three microlens arrays with different pitch to find first order parameters of the imaging system. A 2mm thin imaging system with 21x3 channels, 70 masculinex10 masculine field of view and 4.5mm x 0.5mm image size is optimized and analyzed using sequential and non-sequential raytracing and fabricated by microoptics technology. Anamorphic lenses, where the parameters are a function of the considered optical channel, are used to achieve a homogeneous optical performance over the whole field of view. Captured images are presented and compared to simulation results. PMID:19494951

  11. [Gunshot into the eye].

    PubMed

    Schyma, C; Schyma, P

    1996-01-01

    A 55-year-old man was found dead sitting at his work-bench. A pistol Parabellum 1908 (9 mm Luger) was disassembled on the work-table. A pack of 9 mm Luger full metal jacket ammunition was opened. The left side of his glasses and the left eye were injured. The autopsy proved the death from air embolism. Radiography of the head revealed metallic fragments along the bullet path. The bullet had lost the jacket and the core was fragmented. Gunshot residues on the hands of the deceased and on the left side of the face indicated that the lethal injury was self inflicted. The function of the pistol "08" explicated that a shot could be fired from the isolated barrel which formed a unit with the bolt. The bullet showed traces of manipulation. In the house there were found other self-made dumdum-bullets. Death could be explained as an accident while cleaning the pistol.

  12. Eyes of Ganges

    NASA Technical Reports Server (NTRS)

    2005-01-01

    21 December 2005 This Mars Global Surveyor (MGS) Mars Orbiter Camera (MOC) image shows eroded, light-toned layered rock outcrops on the side of a large mound in Ganges Chasma, part of the vast Valles Marineris trough system. Perhaps a testament to the inherent human (and primate) ability to pick out faces where partially hidden from view (even when a face is not really there) -- near the top of this picture are two features, each a product of erosion, resembling a pair of human eyes. This picture was acquired in late November 2005.

    Location near: 7.1oS, 49.4oW Image width: width: 0.55 km (0.3 mi) Illumination from: left/lower left Season: Southern Summer

  13. [Diabetic eye disease].

    PubMed

    Henriques, José; Vaz-Pereira, Sara; Nascimento, João; Rosa, Paulo Caldeira

    2015-01-01

    Diabetes mellitus is a chronic metabolic disease characterized by sustained hyperglycemia leading to macro and microvascular complications. The eye is one of the main organs affected by this disease, being diabetic retinopathy the most well-known microvascular complication and the leading cause of blindness in the working age population. However, diabetic ocular disease is not only characterized by diabetic retinopathy. Other important ocular manifestations of diabetes mellitus include cataract, glaucoma, ischemic optic neuropathy, cranial nerve palsies and recurrent corneal erosion syndrome. Here, we emphasize diabetic retinopathy as the most important and characteristic complication of diabetes mellitus, but also review less well-known complications with the aim to alert and sensitize non-ophthalmologist clinicians that treat diabetic individuals, in order to promote an early diagnosis and treatment of the sight-threatening complications of diabetes.

  14. [Eye and sarcoidosis].

    PubMed

    Weber, M

    1999-11-15

    Sarcoidosis is a multisystem granulomatous disease, of unknown cause, characterised by non-caseating granulomas. The most common organs involved are the lung, thoracic lymph nodes, skin and eyes. Ophthalmic involvement occurred in approximately 30% of the patients and could be the first manifestation of the disease and preceding pulmonary involvement for many years. If anterior uveitis is the most common ocular manifestation, the posterior segment involvement (intermediate uveitis, vasculitis, choroidal granuloma, macular oedema...) is less common but more visually disabling. The non specific ocular manifestations of the disease make it as a difficult diagnosis. The "suspected sarcoidosis" diagnosis is made with regards to clinical, radiological and (or) biological criteria and the "definitive diagnosis" require the demonstration of a non-caseating, granulomatous, non-infectious inflammation process on biopsy.

  15. Pregnancy and the Eye

    PubMed Central

    Yenerel, Nursal Melda; Küçümen, Raciha Beril

    2015-01-01

    Pregnancy causes significant changes in all systems of the body. Although most of them are physiological, they may also lead to pathological consequences. The resulting pathological changes may occur for the first time or existing diseases affected by pregnancy can become more serious or change course. Diseases specific only to pregnancy may arise. Like all systems of the body, the visual system is also affected by pregnancy, developing a wide range of physiological and pathological changes. Knowing the ocular physiological changes and diagnosing eye diseases that may develop during pregnancy, and preventing and treating these diseases is crucial to ensure the baby’s healthy development. Therefore, we have reviewed the conditions that an ophthalmologist should recognize, follow-up, and pay attention to during treatment and summarized them under the topic “pregnancy and the eye”. PMID:27800235

  16. The Colossal Cosmic Eye

    NASA Astrophysics Data System (ADS)

    2005-09-01

    Eighty-five million years ago on small planet Earth, dinosaurs ruled, ignorant of their soon-to-come demise in the great Jurassic extinction, while mammals were still small and shy creatures. The southern Andes of Bolivia, Chile, and Argentina were not yet formed and South America was still an island continent. Eighty-five million years ago, our Sun and its solar system was 60,000 light years away from where it now stands [1]. Eighty-five million years ago, in another corner of the Universe, light left the beautiful spiral galaxy NGC 1350, for a journey across the universe. Part of this light was recorded at the beginning of the year 2000 AD by ESO's Very Large Telescope, located on the 2,600m high Cerro Paranal in the Chilean Andes on planet Earth. Astronomers classify NGC 1350 as an Sa(r) type galaxy, meaning it is a spiral with large central regions. In fact, NGC 1350 lies at the border between the broken-ring spiral type and a grand design spiral with two major outer arms. It is about 130,000 light-years across and, hence, is slightly larger than our Milky Way. The rather faint and graceful outer arms originate at the inner main ring and can be traced for almost half a circle when they each meet the opposite arm, giving the impression of completing a second outer ring, the "eye". The arms are given a blue tint as a result of the presence of very young and massive stars. The amount of dust, seen as small fragmented dust spirals in the central part of the galaxy and producing a fine tapestry that bear resemblance with blood vessels in the eye, is also a signature of the formation of stars.

  17. Miniature curved artificial compound eyes

    PubMed Central

    Floreano, Dario; Pericet-Camara, Ramon; Viollet, Stéphane; Ruffier, Franck; Brückner, Andreas; Leitel, Robert; Buss, Wolfgang; Menouni, Mohsine; Expert, Fabien; Juston, Raphaël; Dobrzynski, Michal Karol; L’Eplattenier, Geraud; Recktenwald, Fabian; Mallot, Hanspeter A.; Franceschini, Nicolas

    2013-01-01

    In most animal species, vision is mediated by compound eyes, which offer lower resolution than vertebrate single-lens eyes, but significantly larger fields of view with negligible distortion and spherical aberration, as well as high temporal resolution in a tiny package. Compound eyes are ideally suited for fast panoramic motion perception. Engineering a miniature artificial compound eye is challenging because it requires accurate alignment of photoreceptive and optical components on a curved surface. Here, we describe a unique design method for biomimetic compound eyes featuring a panoramic, undistorted field of view in a very thin package. The design consists of three planar layers of separately produced arrays, namely, a microlens array, a neuromorphic photodetector array, and a flexible printed circuit board that are stacked, cut, and curved to produce a mechanically flexible imager. Following this method, we have prototyped and characterized an artificial compound eye bearing a hemispherical field of view with embedded and programmable low-power signal processing, high temporal resolution, and local adaptation to illumination. The prototyped artificial compound eye possesses several characteristics similar to the eye of the fruit fly Drosophila and other arthropod species. This design method opens up additional vistas for a broad range of applications in which wide field motion detection is at a premium, such as collision-free navigation of terrestrial and aerospace vehicles, and for the experimental testing of insect vision theories. PMID:23690574

  18. Eye Injuries Can Be Prevented.

    ERIC Educational Resources Information Center

    PTA Today, 1987

    1987-01-01

    Eleven thousand eye injuries are suffered annually by 5- to-14-year-old youngsters during sports and recreational activities. Baseball-related accidents result in more eye injuries to youth than any other sport. Protective face gear is discussed and recommended. (MT)

  19. Photographic Screening for Eye Defects

    NASA Technical Reports Server (NTRS)

    Richardson, J.

    1985-01-01

    Images of retinas examined for characteristic patterns. Color photographs of retinas taken. Proper alinement of eye obtained by asking subject to gaze at light-emitting diode. "Red-eye" patterns in resulting color photographs examined by trained observers for signs of ocular defects. System used to check power of contact lenses and eyeglasses by taking photographs with these items in place.

  20. Miniature curved artificial compound eyes.

    PubMed

    Floreano, Dario; Pericet-Camara, Ramon; Viollet, Stéphane; Ruffier, Franck; Brückner, Andreas; Leitel, Robert; Buss, Wolfgang; Menouni, Mohsine; Expert, Fabien; Juston, Raphaël; Dobrzynski, Michal Karol; L'Eplattenier, Geraud; Recktenwald, Fabian; Mallot, Hanspeter A; Franceschini, Nicolas

    2013-06-01

    In most animal species, vision is mediated by compound eyes, which offer lower resolution than vertebrate single-lens eyes, but significantly larger fields of view with negligible distortion and spherical aberration, as well as high temporal resolution in a tiny package. Compound eyes are ideally suited for fast panoramic motion perception. Engineering a miniature artificial compound eye is challenging because it requires accurate alignment of photoreceptive and optical components on a curved surface. Here, we describe a unique design method for biomimetic compound eyes featuring a panoramic, undistorted field of view in a very thin package. The design consists of three planar layers of separately produced arrays, namely, a microlens array, a neuromorphic photodetector array, and a flexible printed circuit board that are stacked, cut, and curved to produce a mechanically flexible imager. Following this method, we have prototyped and characterized an artificial compound eye bearing a hemispherical field of view with embedded and programmable low-power signal processing, high temporal resolution, and local adaptation to illumination. The prototyped artificial compound eye possesses several characteristics similar to the eye of the fruit fly Drosophila and other arthropod species. This design method opens up additional vistas for a broad range of applications in which wide field motion detection is at a premium, such as collision-free navigation of terrestrial and aerospace vehicles, and for the experimental testing of insect vision theories. PMID:23690574

  1. Miniature curved artificial compound eyes.

    PubMed

    Floreano, Dario; Pericet-Camara, Ramon; Viollet, Stéphane; Ruffier, Franck; Brückner, Andreas; Leitel, Robert; Buss, Wolfgang; Menouni, Mohsine; Expert, Fabien; Juston, Raphaël; Dobrzynski, Michal Karol; L'Eplattenier, Geraud; Recktenwald, Fabian; Mallot, Hanspeter A; Franceschini, Nicolas

    2013-06-01

    In most animal species, vision is mediated by compound eyes, which offer lower resolution than vertebrate single-lens eyes, but significantly larger fields of view with negligible distortion and spherical aberration, as well as high temporal resolution in a tiny package. Compound eyes are ideally suited for fast panoramic motion perception. Engineering a miniature artificial compound eye is challenging because it requires accurate alignment of photoreceptive and optical components on a curved surface. Here, we describe a unique design method for biomimetic compound eyes featuring a panoramic, undistorted field of view in a very thin package. The design consists of three planar layers of separately produced arrays, namely, a microlens array, a neuromorphic photodetector array, and a flexible printed circuit board that are stacked, cut, and curved to produce a mechanically flexible imager. Following this method, we have prototyped and characterized an artificial compound eye bearing a hemispherical field of view with embedded and programmable low-power signal processing, high temporal resolution, and local adaptation to illumination. The prototyped artificial compound eye possesses several characteristics similar to the eye of the fruit fly Drosophila and other arthropod species. This design method opens up additional vistas for a broad range of applications in which wide field motion detection is at a premium, such as collision-free navigation of terrestrial and aerospace vehicles, and for the experimental testing of insect vision theories.

  2. The RapidEye mission design

    NASA Astrophysics Data System (ADS)

    Tyc, George; Tulip, John; Schulten, Daniel; Krischke, Manfred; Oxfort, Michael

    2005-01-01

    The RapidEye mission is a commercial remote sensing mission by the German Company RapidEye AG. The RapidEye mission will deliver information products for various customers in the agricultural insurance market, large producers, international institutions and cartography. The mission consists of a constellation of five identical small satellites and a sophisticated ground infrastructure based on proven systems. The five satellites will be placed in a single sun-synchronous orbit of approximately 620 km, with the satellites equally spaced over the orbit. The RapidEye system has the unique ability to image any area on earth once per day and can also provide large area coverage within 5 days. The satellites will each carry a 5 band multi-spectral optical imager with a ground sampling distance of 6.5 m at nadir and a swath width of 80 km. These capabilities along with the processing throughput of the ground segment allows the system to deliver the information products needed by the customers reliably and in a time frame that meets their specific needs.

  3. Learning rational temporal eye movement strategies.

    PubMed

    Hoppe, David; Rothkopf, Constantin A

    2016-07-19

    During active behavior humans redirect their gaze several times every second within the visual environment. Where we look within static images is highly efficient, as quantified by computational models of human gaze shifts in visual search and face recognition tasks. However, when we shift gaze is mostly unknown despite its fundamental importance for survival in a dynamic world. It has been suggested that during naturalistic visuomotor behavior gaze deployment is coordinated with task-relevant events, often predictive of future events, and studies in sportsmen suggest that timing of eye movements is learned. Here we establish that humans efficiently learn to adjust the timing of eye movements in response to environmental regularities when monitoring locations in the visual scene to detect probabilistically occurring events. To detect the events humans adopt strategies that can be understood through a computational model that includes perceptual and acting uncertainties, a minimal processing time, and, crucially, the intrinsic costs of gaze behavior. Thus, subjects traded off event detection rate with behavioral costs of carrying out eye movements. Remarkably, based on this rational bounded actor model the time course of learning the gaze strategies is fully explained by an optimal Bayesian learner with humans' characteristic uncertainty in time estimation, the well-known scalar law of biological timing. Taken together, these findings establish that the human visual system is highly efficient in learning temporal regularities in the environment and that it can use these regularities to control the timing of eye movements to detect behaviorally relevant events.

  4. Learning rational temporal eye movement strategies.

    PubMed

    Hoppe, David; Rothkopf, Constantin A

    2016-07-19

    During active behavior humans redirect their gaze several times every second within the visual environment. Where we look within static images is highly efficient, as quantified by computational models of human gaze shifts in visual search and face recognition tasks. However, when we shift gaze is mostly unknown despite its fundamental importance for survival in a dynamic world. It has been suggested that during naturalistic visuomotor behavior gaze deployment is coordinated with task-relevant events, often predictive of future events, and studies in sportsmen suggest that timing of eye movements is learned. Here we establish that humans efficiently learn to adjust the timing of eye movements in response to environmental regularities when monitoring locations in the visual scene to detect probabilistically occurring events. To detect the events humans adopt strategies that can be understood through a computational model that includes perceptual and acting uncertainties, a minimal processing time, and, crucially, the intrinsic costs of gaze behavior. Thus, subjects traded off event detection rate with behavioral costs of carrying out eye movements. Remarkably, based on this rational bounded actor model the time course of learning the gaze strategies is fully explained by an optimal Bayesian learner with humans' characteristic uncertainty in time estimation, the well-known scalar law of biological timing. Taken together, these findings establish that the human visual system is highly efficient in learning temporal regularities in the environment and that it can use these regularities to control the timing of eye movements to detect behaviorally relevant events. PMID:27382164

  5. Historical perspective on the development and evolution of eyes and photoreceptors.

    PubMed

    Gehring, Walter J

    2004-01-01

    The development and evolution of eyes is an "old problem" in biology, which required a special treatment in Charles Darwin's "Origin of the species" (1882) under the heading of "Difficulties of the theory". Darwin postulated a simple and imperfect eye, as a prototype, which can vary and evolve under natural selection into more complex and perfect eyes. Based upon morphological criteria and the different modes of development of the different kinds of eyes, neodarwinists have postulated that the various eye-types are polyphyletic in origin and that the eyes have evolved independently in the various animal phyla. Recent developmental genetic experiments and molecular phylogenetic analyses cast serious doubts on this interpretation and argue strongly for a monophyletic origin of the eyes from a Darwinian prototype and subsequent divergent, parallel and convergent evolution leading to the various eye-types. PMID:15558463

  6. Historical perspective on the development and evolution of eyes and photoreceptors.

    PubMed

    Gehring, Walter J

    2004-01-01

    The development and evolution of eyes is an "old problem" in biology, which required a special treatment in Charles Darwin's "Origin of the species" (1882) under the heading of "Difficulties of the theory". Darwin postulated a simple and imperfect eye, as a prototype, which can vary and evolve under natural selection into more complex and perfect eyes. Based upon morphological criteria and the different modes of development of the different kinds of eyes, neodarwinists have postulated that the various eye-types are polyphyletic in origin and that the eyes have evolved independently in the various animal phyla. Recent developmental genetic experiments and molecular phylogenetic analyses cast serious doubts on this interpretation and argue strongly for a monophyletic origin of the eyes from a Darwinian prototype and subsequent divergent, parallel and convergent evolution leading to the various eye-types.

  7. Axial length in eyes with bilateral pediatric cataract at tertiary eye care center in Nepal: a preliminary report.

    PubMed

    Shrestha, U D; Shrestha, M K

    2011-03-01

    The aim of the study was to determine the average axial length reading of the bilateral pediatric cataract undergoing cataract surgery. Pre-operative axial length measurement was done in 80 children below 15 years who had bilateral pediatric cataract. Axial length measurement was done in 56 fellow eyes. The axial length was measured under general anesthesia with the Accutome A-scan. The mean age was 69.7 months (SD=52.6), range from one month to 168 months. The mean axial length reading was 21.3 mm in operated eyes and 21.1 mm in fellow eyes. The range of axial length reading was 16.2 -31.5 mm in operated eyes and it was 16.5 -31.5 mm in fellow eyes. This short observation found that in bilateral pediatric cataract, the axial length value is similar in both operated and fellow eyes. Based on the axial length value of the operated eye, the patients with bilateral congenital cataract can undergo surgery in those eye hospitals where facilities of measurement of axial length is not available.

  8. Keratometry in eyes with bilateral pediatric cataract at tertiary eye care center in Nepal: a preliminary report.

    PubMed

    Shrestha, U D; Shrestha, M K

    2009-09-01

    Pre-operative keratometry measurement of the subjects was done in 80 children with bilateral congenital cataract below 15 years who had undergone pediatric cataract surgery. The objective of the study was to evaluate the average keratometry reading in Nepalese children with bilateral cataract. The keratometry reading was taken under general anesthesia with the Nidek Auto Keratometer, model KM-500. The mean age was 69.7 months (SD = 52.6), range from one month to 168 months. The mean keratometry reading was 44.8 (SD = 2.7) in operated eyes and 44.7 (SD = 2.6) in fellow eyes. The minimum and the maximum values of keratometry reading in operated eyes were 39.4 and 51.5 respectively where as it was 40.3 and 51.5 in fellow eyes. We concluded that in bilateral pediatric cataract the keratometry value is similar in both operated and fellow eyes. Based on the keratometry value of the operated eye, the patients with bilateral congenital cataract can undergo surgery in those eye hospitals where facilities of the keratometry is not available under general anesthesia. We also recommended that additional study on axial length will be needed to calculate the Intra Ocular Lens power in fellow eye.

  9. Evaluation of the Painful Eye.

    PubMed

    Pflipsen, Matthew; Massaquoi, Mariama; Wolf, Suzanne

    2016-06-15

    Eye problems constitute 2% to 3% of all primary care and emergency department visits. Common eye conditions that can cause eye pain are conjunctivitis, corneal abrasion, and hordeolum, and some of the most serious eye conditions include acute angle-closure glaucoma, orbital cellulitis, and herpetic keratitis. The history should focus on vision changes, foreign body sensation, photophobia, and associated symptoms, such as headache. The physical examination includes an assessment of visual acuity and systematic evaluation of the conjunctiva, eyelids, sclera, cornea, pupil, anterior chamber, and anterior uvea. Further examination with fluorescein staining and tonometry is often necessary. Because eye pain can be the first sign of an ophthalmologic emergency, the physician should determine if referral is warranted. Specific conditions that require ophthalmology consultation include acute angle-closure glaucoma, optic neuritis, orbital cellulitis, scleritis, anterior uveitis, and infectious keratitis. PMID:27304768

  10. Method for Improving EEG Based Emotion Recognition by Combining It with Synchronized Biometric and Eye Tracking Technologies in a Non-invasive and Low Cost Way

    PubMed Central

    López-Gil, Juan-Miguel; Virgili-Gomá, Jordi; Gil, Rosa; García, Roberto

    2016-01-01

    Technical advances, particularly the integration of wearable and embedded sensors, facilitate tracking of physiological responses in a less intrusive way. Currently, there are many devices that allow gathering biometric measurements from human beings, such as EEG Headsets or Health Bracelets. The massive data sets generated by tracking of EEG and physiology may be used, among other things, to infer knowledge about human moods and emotions. Apart from direct biometric signal measurement, eye tracking systems are nowadays capable of determining the point of gaze of the users when interacting in ICT environments, which provides an added value research on many different areas, such as psychology or marketing. We present a process in which devices for eye tracking, biometric, and EEG signal measurements are synchronously used for studying both basic and complex emotions. We selected the least intrusive devices for different signal data collection given the study requirements and cost constraints, so users would behave in the most natural way possible. On the one hand, we have been able to determine basic emotions participants were experiencing by means of valence and arousal. On the other hand, a complex emotion such as empathy has also been detected. To validate the usefulness of this approach, a study involving forty-four people has been carried out, where they were exposed to a series of affective stimuli while their EEG activity, biometric signals, and eye position were synchronously recorded to detect self-regulation. The hypothesis of the work was that people who self-regulated would show significantly different results when analyzing their EEG data. Participants were divided into two groups depending on whether Electro Dermal Activity (EDA) data indicated they self-regulated or not. The comparison of the results obtained using different machine learning algorithms for emotion recognition shows that using EEG activity alone as a predictor for self-regulation does

  11. Method for Improving EEG Based Emotion Recognition by Combining It with Synchronized Biometric and Eye Tracking Technologies in a Non-invasive and Low Cost Way.

    PubMed

    López-Gil, Juan-Miguel; Virgili-Gomá, Jordi; Gil, Rosa; García, Roberto

    2016-01-01

    Technical advances, particularly the integration of wearable and embedded sensors, facilitate tracking of physiological responses in a less intrusive way. Currently, there are many devices that allow gathering biometric measurements from human beings, such as EEG Headsets or Health Bracelets. The massive data sets generated by tracking of EEG and physiology may be used, among other things, to infer knowledge about human moods and emotions. Apart from direct biometric signal measurement, eye tracking systems are nowadays capable of determining the point of gaze of the users when interacting in ICT environments, which provides an added value research on many different areas, such as psychology or marketing. We present a process in which devices for eye tracking, biometric, and EEG signal measurements are synchronously used for studying both basic and complex emotions. We selected the least intrusive devices for different signal data collection given the study requirements and cost constraints, so users would behave in the most natural way possible. On the one hand, we have been able to determine basic emotions participants were experiencing by means of valence and arousal. On the other hand, a complex emotion such as empathy has also been detected. To validate the usefulness of this approach, a study involving forty-four people has been carried out, where they were exposed to a series of affective stimuli while their EEG activity, biometric signals, and eye position were synchronously recorded to detect self-regulation. The hypothesis of the work was that people who self-regulated would show significantly different results when analyzing their EEG data. Participants were divided into two groups depending on whether Electro Dermal Activity (EDA) data indicated they self-regulated or not. The comparison of the results obtained using different machine learning algorithms for emotion recognition shows that using EEG activity alone as a predictor for self-regulation does

  12. Method for Improving EEG Based Emotion Recognition by Combining It with Synchronized Biometric and Eye Tracking Technologies in a Non-invasive and Low Cost Way.

    PubMed

    López-Gil, Juan-Miguel; Virgili-Gomá, Jordi; Gil, Rosa; García, Roberto

    2016-01-01

    Technical advances, particularly the integration of wearable and embedded sensors, facilitate tracking of physiological responses in a less intrusive way. Currently, there are many devices that allow gathering biometric measurements from human beings, such as EEG Headsets or Health Bracelets. The massive data sets generated by tracking of EEG and physiology may be used, among other things, to infer knowledge about human moods and emotions. Apart from direct biometric signal measurement, eye tracking systems are nowadays capable of determining the point of gaze of the users when interacting in ICT environments, which provides an added value research on many different areas, such as psychology or marketing. We present a process in which devices for eye tracking, biometric, and EEG signal measurements are synchronously used for studying both basic and complex emotions. We selected the least intrusive devices for different signal data collection given the study requirements and cost constraints, so users would behave in the most natural way possible. On the one hand, we have been able to determine basic emotions participants were experiencing by means of valence and arousal. On the other hand, a complex emotion such as empathy has also been detected. To validate the usefulness of this approach, a study involving forty-four people has been carried out, where they were exposed to a series of affective stimuli while their EEG activity, biometric signals, and eye position were synchronously recorded to detect self-regulation. The hypothesis of the work was that people who self-regulated would show significantly different results when analyzing their EEG data. Participants were divided into two groups depending on whether Electro Dermal Activity (EDA) data indicated they self-regulated or not. The comparison of the results obtained using different machine learning algorithms for emotion recognition shows that using EEG activity alone as a predictor for self-regulation does

  13. Method for Improving EEG Based Emotion Recognition by Combining It with Synchronized Biometric and Eye Tracking Technologies in a Non-invasive and Low Cost Way

    PubMed Central

    López-Gil, Juan-Miguel; Virgili-Gomá, Jordi; Gil, Rosa; García, Roberto

    2016-01-01

    Technical advances, particularly the integration of wearable and embedded sensors, facilitate tracking of physiological responses in a less intrusive way. Currently, there are many devices that allow gathering biometric measurements from human beings, such as EEG Headsets or Health Bracelets. The massive data sets generated by tracking of EEG and physiology may be used, among other things, to infer knowledge about human moods and emotions. Apart from direct biometric signal measurement, eye tracking systems are nowadays capable of determining the point of gaze of the users when interacting in ICT environments, which provides an added value research on many different areas, such as psychology or marketing. We present a process in which devices for eye tracking, biometric, and EEG signal measurements are synchronously used for studying both basic and complex emotions. We selected the least intrusive devices for different signal data collection given the study requirements and cost constraints, so users would behave in the most natural way possible. On the one hand, we have been able to determine basic emotions participants were experiencing by means of valence and arousal. On the other hand, a complex emotion such as empathy has also been detected. To validate the usefulness of this approach, a study involving forty-four people has been carried out, where they were exposed to a series of affective stimuli while their EEG activity, biometric signals, and eye position were synchronously recorded to detect self-regulation. The hypothesis of the work was that people who self-regulated would show significantly different results when analyzing their EEG data. Participants were divided into two groups depending on whether Electro Dermal Activity (EDA) data indicated they self-regulated or not. The comparison of the results obtained using different machine learning algorithms for emotion recognition shows that using EEG activity alone as a predictor for self-regulation does

  14. The Ex Vivo Eye Irritation Test as an alternative test method for serious eye damage/eye irritation.

    PubMed

    Spöler, Felix; Kray, Oya; Kray, Stefan; Panfil, Claudia; Schrage, Norbert F

    2015-07-01

    Ocular irritation testing is a common requirement for the classification, labelling and packaging of chemicals (substances and mixtures). The in vivo Draize rabbit eye test (OECD Test Guideline 405) is considered to be the regulatory reference method for the classification of chemicals according to their potential to induce eye injury. In the Draize test, chemicals are applied to rabbit eyes in vivo, and changes are monitored over time. If no damage is observed, the chemical is not categorised. Otherwise, the classification depends on the severity and reversibility of the damage. Alternative test methods have to be designed to match the classifications from the in vivo reference method. However, observation of damage reversibility is usually not possible in vitro. Within the present study, a new organotypic method based on rabbit corneas obtained from food production is demonstrated to close this gap. The Ex Vivo Eye Irritation Test (EVEIT) retains the full biochemical activity of the corneal epithelium, epithelial stem cells and endothelium. This permits the in-depth analysis of ocular chemical trauma beyond that achievable by using established in vitro methods. In particular, the EVEIT is the first test to permit the direct monitoring of recovery of all corneal layers after damage. To develop a prediction model for the EVEIT that is comparable to the GHS system, 37 reference chemicals were analysed. The experimental data were used to derive a three-level potency ranking of eye irritation and corrosion that best fits the GHS categorisation. In vivo data available in the literature were used for comparison. When compared with GHS classification predictions, the overall accuracy of the three-level potency ranking was 78%. The classification of chemicals as irritating versus non-irritating resulted in 96% sensitivity, 91% specificity and 95% accuracy.

  15. "Doctor my eyes": A natural experiment on the demand for eye care services.

    PubMed

    Dickey, H; Ikenwilo, D; Norwood, P; Watson, V; Zangelidis, A

    2016-02-01

    Preventive health care is promoted by many organisations from the World Health Organisation (WHO) to regional and national governments. The degree of cost-sharing between individuals and the health care service affects preventive service use. For instance, out-of-pocket fees that are paid by individuals for curative services reduce preventive care demand. We examine the impact of subsidised preventive care on demand. We motivate our analysis with a theoretical model of inter-temporal substitution in which individuals decide whether to have a health examination in period one and consequently whether to be treated if required in period two. We derive four testable hypotheses. We test these using the subsidised eye care policy introduced in Scotland in 2006. This provides a natural experiment that allows us to identify the effect of the policy on the demand for eye examinations. We also explore socio-economic differences in the response to the policy. The analysis is based on a sample from the British Household Panel Survey of 52,613 observations of people, aged between 16 and 59 years, living in England and Scotland for the period 2001-2008. Using the difference-in-difference methodology, we find that on average the policy did not affect demand for eye examinations. We find that demand for eye examinations only increased among high income households, and consequently, inequalities in eye-care services demand have widened in Scotland since the introduction of the policy.

  16. An Eye on Trafficking Genes: Identification of Four Eye Color Mutations in Drosophila

    PubMed Central

    Grant, Paaqua; Maga, Tara; Loshakov, Anna; Singhal, Rishi; Wali, Aminah; Nwankwo, Jennifer; Baron, Kaitlin; Johnson, Diana

    2016-01-01

    Genes that code for proteins involved in organelle biogenesis and intracellular trafficking produce products that are critical in normal cell function . Conserved orthologs of these are present in most or all eukaryotes, including Drosophila melanogaster. Some of these genes were originally identified as eye color mutants with decreases in both types of pigments found in the fly eye. These criteria were used for identification of such genes, four eye color mutations that are not annotated in the genome sequence: chocolate, maroon, mahogany, and red Malpighian tubules were molecularly mapped and their genome sequences have been evaluated. Mapping was performed using deletion analysis and complementation tests. chocolate is an allele of the VhaAC39-1 gene, which is an ortholog of the Vacuolar H+ ATPase AC39 subunit 1. maroon corresponds to the Vps16A gene and its product is part of the HOPS complex, which participates in transport and organelle fusion. red Malpighian tubule is the CG12207 gene, which encodes a protein of unknown function that includes a LysM domain. mahogany is the CG13646 gene, which is predicted to be an amino acid transporter. The strategy of identifying eye color genes based on perturbations in quantities of both types of eye color pigments has proven useful in identifying proteins involved in trafficking and biogenesis of lysosome-related organelles. Mutants of these genes can form the basis of valuable in vivo models to understand these processes. PMID:27558665

  17. Genetics Home Reference: fish-eye disease

    MedlinePlus

    ... Understand Genetics Home Health Conditions fish-eye disease fish-eye disease Enable Javascript to view the expand/ ... boxes. Download PDF Open All Close All Description Fish-eye disease , also called partial LCAT deficiency, is ...

  18. Tamoxifen-Containing Eye Drops Successfully Trigger Cre-Mediated Recombination in the Entire Eye.

    PubMed

    Schlecht, Anja; Leimbeck, Sarah V; Tamm, Ernst R; Braunger, Barbara M

    2016-01-01

    Embryonic lethality in mice with targeted gene deletion is a major issue that can be circumvented by using Cre-loxP-based animal models. Various inducible Cre systems are available, e.g. such that are activated following tamoxifen treatment, and allow deletion of a specific target gene at any desired time point during the life span of the animal. In this study, we describe the efficiency of topical tamoxifen administration by eye drops using a Cre- reporter mouse strain (R26R). We report that tamoxifen-responsive CAGGCre-ER (TM) mice show a robust Cre- mediated recombination throughout the entire eye.

  19. Eye growth and myopia development: Unifying theory and Matlab model.

    PubMed

    Hung, George K; Mahadas, Kausalendra; Mohammad, Faisal

    2016-03-01

    The aim of this article is to present an updated unifying theory of the mechanisms underlying eye growth and myopia development. A series of model simulation programs were developed to illustrate the mechanism of eye growth regulation and myopia development. Two fundamental processes are presumed to govern the relationship between physiological optics and eye growth: genetically pre-programmed signaling and blur feedback. Cornea/lens is considered to have only a genetically pre-programmed component, whereas eye growth is considered to have both a genetically pre-programmed and a blur feedback component. Moreover, based on the Incremental Retinal-Defocus Theory (IRDT), the rate of change of blur size provides the direction for blur-driven regulation. The various factors affecting eye growth are shown in 5 simulations: (1 - unregulated eye growth): blur feedback is rendered ineffective, as in the case of form deprivation, so there is only genetically pre-programmed eye growth, generally resulting in myopia; (2 - regulated eye growth): blur feedback regulation demonstrates the emmetropization process, with abnormally excessive or reduced eye growth leading to myopia and hyperopia, respectively; (3 - repeated near-far viewing): simulation of large-to-small change in blur size as seen in the accommodative stimulus/response function, and via IRDT as well as nearwork-induced transient myopia (NITM), leading to the development of myopia; (4 - neurochemical bulk flow and diffusion): release of dopamine from the inner plexiform layer of the retina, and the subsequent diffusion and relay of neurochemical cascade show that a decrease in dopamine results in a reduction of proteoglycan synthesis rate, which leads to myopia; (5 - Simulink model): model of genetically pre-programmed signaling and blur feedback components that allows for different input functions to simulate experimental manipulations that result in hyperopia, emmetropia, and myopia. These model simulation programs

  20. Flap Thickness in Eyes with Ectasia after LASIK

    PubMed Central

    Randleman, J. Bradley; Hebson, Carolyn B.; Larson, Paul M.

    2015-01-01

    Purpose To measure central flap thickness in eyes with ectasia after LASIK and to compare these values with estimated anticipated flap thickness based on average published values for each device used for flap creation. Setting Emory Vision at Emory University, Atlanta GA, USA Methods Confocal microscopic analysis using the Confoscan 3 (Nidek technologies) to measure central flap thickness in eyes with ectasia after LASIK, and evaluation of pre-LASIK records, including basic patient demographics, preoperative corneal topographies, estimated anticipated flap thickness based on published average thickness values, and residual stromal bed thickness (RSB) calculations using both measured and estimated flap thicknesses. Results Fifty eyes from 29 patients were evaluated. Average measured flap thickness was (138 ± 26 μ, range 90 to 220 μ). There were no significant differences between measured and estimated flap thicknesses (138 vs. 135 μ, p = 0.5) or RSB (329 vs. 332 μ, p = 0.7), nor were there any differences in flap thickness between eyes with normal or abnormal corneal topographies. Only one eye had a measured flap resulting in unintended RSB < 250 microns; this occurred in an eye with abnormal topography. Conclusions Measured central flap thickness was not thicker than estimated for the vast majority of eyes developing ectasia after LASIK. Thus, excessively thick flaps do not appear to be a major contributing factor to the pathogenesis of ectasia after LASIK. PMID:22424807

  1. Saccadic eye movements of dyslexic adult subjects.

    PubMed

    Fischer, B; Biscaldi, M; Otto, P

    1993-09-01

    The characteristics of visually guided saccadic eye movements were compared in 12 normal adult subjects and 12 test subjects of normal intelligence, but with problems in reading and writing. All subjects were examined psychometrically for different cognitive abilities, and for their reading and writing capabilities. The anamnestic reports about their reading and writing problems earlier in their lives were analysed. Based on scores of the writing and reading tests, the test group was subdivided into two subgroups: A and B (group A reached medium, group B very low scores in both tests). Five different non-cognitive eye movement tasks were applied: two single tasks (gap and overlap) requiring single saccades from a fixation point to a peripherally appearing target and three sequential tasks (overlap, synchronous, and simultaneous) requiring sequences of saccades to four equally spaced targets presented sequentially to the right side from an initial fixation point. Many parameters of the subjects' eye movement performance were determined and their mean values were calculated for each subject. The Student t-test revealed that the eye movement data of the two test groups deviated differently from the data of the control group. Group B had the largest deviation of the eye movement parameter from the control group. The differentiating parameters were the consistency of target acquisition, the saccadic reaction time, and the number of anticipatory responses in the single target tasks. In the sequential tasks these differences were in the amplitude, the number of saccades, and the fixation durations. The incidence of regressive saccades did not discriminate between test subjects and controls. The possible underlying deficits in the attentional control over the saccadic system and their implications for reading are discussed.

  2. An eye on inflammatory eye disease.

    PubMed

    Kestelyn, P G

    2005-01-01

    The purpose of this article is to outline the interaction between ophthalmologists and internists in the management of uveitis. Two issues will be addressed: 1) which strategies should the internist follow when asked to investigate a case of uveitis; and 2) in which systemic diseases should the internist order an ocular examination to rule out intraocular inflammation. The modern approach to the diagnosis of uveitis is based on the naming-meshing system popularized by Smith and Nozik. After a short history (ocular complaints, general health) an ophthalmic examination is carried out to determine the anatomic structures involved. Based on the results a uveitis is classified as anterior uveitis, intermediate uveitis, posterior uveitis, or panuveitis. Associated factors (eg, unilateral versus bilateral, acute versus chronic, granulomatous versus nongranulomatous, etc.) are also assessed. Based on this information the type of uveitis will be named (eg, acute, nongranulomatous, unilateral, anterior uveitis) and matched (meshing) to a potential list of etiologies (eg, viral iritis, HLA-B 27 associated iritis). Targeted questioning and selected medical and laboratory investigations based on the shortlist will then identify a possible cause for a particular patient's uveitis. In other words the ophthalmologist should never ask the internist to run the full battery of tests in a patient with uveitis. He rather should indicate which type of uveitis is present and what are the most likely diagnoses to be excluded. Many systemic diseases cause diffuse inflammation and are associated with uveitis. These include tuberculosis, spirochaetal diseases such as Lyme disease and syphilis, sarcoidosis, Behçet syndrome, juvenile idiopathic arthritis, and HIV infection amongst many others. Routine ophthalmic examination in patients with systemic disease may be indicated for diverse reasons: to prevent profound damage due to asymptomatic uveitis in JIA; to detect diagnostic clues in

  3. Wave-front analysis of personal eye protection.

    PubMed

    Eppig, Timo; Zoric, Katja; Speck, Alexis; Zelzer, Benedikt; Götzelmann, Jens; Nagengast, Dieter; Langenbucher, Achim

    2012-07-30

    Shack-Hartmann wave-front sensing has been successfully applied to many fields of optical testing including the human eye itself. We propose wave-front measurement for testing protective eye wear for production control and investigation of aberrations. Refractive power data is derived from the wave-front data and compared to a subjective measurement technique based on a focimeter. Additional image quality classification was performed with a multivariate model using objective parameters to resample a subjectively determined visual quality. Wave-front measurement advances optical testing of protective eye wear and may be used for objective quality control.

  4. Core-shell GaN-ZnO moth-eye nanostructure arrays grown on a-SiO2/Si (1 1 1) as a basis for improved InGaN-based photovoltaics and LEDs

    NASA Astrophysics Data System (ADS)

    Rogers, D. J.; Sandana, V. E.; Gautier, S.; Moudakir, T.; Abid, M.; Ougazzaden, A.; Teherani, F. Hosseini; Bove, P.; Molinari, M.; Troyon, M.; Peres, M.; Soares, Manuel J.; Neves, A. J.; Monteiro, T.; McGrouther, D.; Chapman, J. N.; Drouhin, H.-J.; McClintock, R.; Razeghi, M.

    2015-06-01

    Self-forming, vertically-aligned, ZnO moth-eye-like nanoarrays were grown by catalyst-free pulsed laser deposition on a-SiO2/Si (1 1 1) substrates. X-Ray Diffraction (XRD) and Cathodoluminescence (CL) studies indicated that nanostructures were highly c-axis oriented wurtzite ZnO with strong near band edge emission. The nanostructures were used as templates for the growth of non-polar GaN by metal organic vapor phase epitaxy. XRD, scanning electron microscopy, energy dispersive X-ray microanalysis and CL revealed ZnO encapsulated with GaN, without evidence of ZnO back-etching. XRD showed compressive epitaxial strain in the GaN, which is conducive to stabilization of the higher indium contents required for more efficient green light emitting diode (LED) and photovoltaic (PV) operation. Angular-dependent specular reflection measurements showed a relative reflectance of less than 1% over the wavelength range of 400-720 nm at all angles up to 60°. The superior black-body performance of this moth-eye-like structure would boost LED light extraction and PV anti-reflection performance compared with existing planar or nanowire LED and PV morphologies. The enhancement in core conductivity, provided by the ZnO, would also improve current distribution and increase the effective junction area compared with nanowire devices based solely on GaN.

  5. Keeping our eyes on the eyes: the case of Arcimboldo.

    PubMed

    Bubic, Andreja; Susac, Ana; Palmovic, Marijan

    2014-01-01

    While contemporaries often viewed his reversible composite heads as scherzi (jokes) and modem art connoisseurs as creative masterpieces, Giuseppe Arcimboldo's ingenious paintings served as inspiring stimuli for the present eye-tracking experiment. One group of participants viewed three chosen paintings in an upright, and another in an upside-down, orientation. We compared how participants viewed three selected areas of interest (AOIs) within the painting when these could, and could not, be identified as a face or distinct facial element (eyes and mouth). The obtained results indicate that the participants fixated the parts of the painting which represent faces more in the upright than in the inverted orientation. Furthermore, in the upright orientation the participants focused more on the upper AOls (eyes) than the lower AOIs (mouth). This was not the case for the inverted orientation of two paintings. In conclusion, the face inversion effect occurs even in this artistic context, and the gaze often goes where the eyes are.

  6. The eyes of LITENING

    NASA Astrophysics Data System (ADS)

    Moser, Eric K.

    2016-05-01

    LITENING is an airborne system-of-systems providing long-range imaging, targeting, situational awareness, target tracking, weapon guidance, and damage assessment, incorporating a laser designator and laser range finders, as well as non-thermal and thermal imaging systems, with multi-sensor boresight. Robust operation is at a premium, and subsystems are partitioned to modular, swappable line-replaceable-units (LRUs) and shop-replaceable-units (SRUs). This presentation will explore design concepts for sensing, data storage, and presentation of imagery associated with the LITENING targeting pod. The "eyes" of LITENING are the electro-optic sensors. Since the initial LITENING II introduction to the US market in the late 90s, as the program has evolved and matured, a series of spiral functional improvements and sensor upgrades have been incorporated. These include laser-illuminated imaging, and more recently, color sensing. While aircraft displays are outside of the LITENING system, updates to the available viewing modules have also driven change, and resulted in increasingly effective ways of utilizing the targeting system. One of the latest LITENING spiral upgrades adds a new capability to display and capture visible-band color imagery, using new sensors. This is an augmentation to the system's existing capabilities, which operate over a growing set of visible and invisible colors, infrared bands, and laser line wavelengths. A COTS visible-band camera solution using a CMOS sensor has been adapted to meet the particular needs associated with the airborne targeting use case.

  7. Eyes in the Sky

    NASA Technical Reports Server (NTRS)

    2006-01-01

    These shape-shifting galaxies have taken on the form of a giant mask. The icy blue eyes are actually the cores of two merging galaxies, called NGC 2207 and IC 2163, and the mask is their spiral arms. The false-colored image consists of infrared data from NASA's Spitzer Space Telescope (red) and visible data from NASA's Hubble Space Telescope (blue/green).

    NGC 2207 and IC 2163 met and began a sort of gravitational tango about 40 million years ago. The two galaxies are tugging at each other, stimulating new stars to form. Eventually, this cosmic ball will come to an end, when the galaxies meld into one. The dancing duo is located 140 million light-years away in the Canis Major constellation.

    The infrared data from Spitzer highlight the galaxies' dusty regions, while the visible data from Hubble indicates starlight. In the Hubble-only image (not pictured here), the dusty regions appear as dark lanes.

    The Hubble data correspond to light with wavelengths of .44 and .55 microns (blue and green, respectively). The Spitzer data represent light of 8 microns.

  8. Reconstructing the ancestral butterfly eye: focus on the opsins.

    PubMed

    Briscoe, Adriana D

    2008-06-01

    The eyes of butterflies are remarkable, because they are nearly as diverse as the colors of wings. Much of eye diversity can be traced to alterations in the number, spectral properties and spatial distribution of the visual pigments. Visual pigments are light-sensitive molecules composed of an opsin protein and a chromophore. Most butterflies have eyes that contain visual pigments with a wavelength of peak absorbance, lambda(max), in the ultraviolet (UV, 300-400 nm), blue (B, 400-500 nm) and long wavelength (LW, 500-600 nm) part of the visible light spectrum, respectively, encoded by distinct UV, B and LW opsin genes. In the compound eye of butterflies, each individual ommatidium is composed of nine photoreceptor cells (R1-9) that generally express only one opsin mRNA per cell, although in some butterfly eyes there are ommatidial subtypes in which two opsins are co-expressed in the same photoreceptor cell. Based on a phylogenetic analysis of opsin cDNAs from the five butterfly families, Papilionidae, Pieridae, Nymphalidae, Lycaenidae and Riodinidae, and comparative analysis of opsin gene expression patterns from four of the five families, I propose a model for the patterning of the ancestral butterfly eye that is most closely aligned with the nymphalid eye. The R1 and R2 cells of the main retina expressed UV-UV-, UV-B- or B-B-absorbing visual pigments while the R3-9 cells expressed a LW-absorbing visual pigment. Visual systems of existing butterflies then underwent an adaptive expansion based on lineage-specific B and LW opsin gene multiplications and on alterations in the spatial expression of opsins within the eye. Understanding the molecular sophistication of butterfly eye complexity is a challenge that, if met, has broad biological implications.

  9. Developmental palaeobiology of trilobite eyes and its evolutionary significance

    NASA Astrophysics Data System (ADS)

    Thomas, A. T.

    2005-06-01

    Understanding of the calcified composite eyes of trilobites, the oldest preserved visual system, has advanced greatly in recent decades. Three types of trilobite eye occur, the more derived abathochroal and schizochroal types having evolved neotenically from holochroal eyes. Comparative morphology and phylogenetic considerations suggest that all three eye-types were underlain by common developmental systems. So far, understanding of these systems has been based entirely on morphological data from fossils, particularly the way the visual surface grew and the patterning of lens emplacement. Lenses characteristically form a hexagonal array comprising horizontal rows and, conspicuously in schizochroal eyes, dorso-ventral files. Because individual trilobites sometimes have eyes with different numbers of files, file number must reflect the operation of a developmental programme rather than being under immediate genetic control. An empirical developmental model has been devised to describe trilobite eye development, with separate rules dealing with the initiation of lens emplacement, growth and differentiation of the visual surface, and the termination of lens emplacement. Rarely, trilobites may have visual surfaces of normal size, but which lack lenses. This confirms that visual surface growth must have been regulated separately from lens emplacement, and is a feature that cannot be accounted for by the existing developmental model. Such a developmental separation is one of a number of similarities shared with Drosophila, the modern arthropod in which eye development is best understood. Many aspects of eye development are conserved in the Euarthropoda, and in bilaterian metazoans in general. A revised model for trilobite eye development is proposed using extant phylogenetic bracketing, interpreting morphological data from the fossils in the context of the hierarchy of developmental controls now becoming known from living animals. This new model suggests that overall eye

  10. Interactive Interface with Evolutionary Eye Sensing and Physiological Knowledge

    NASA Astrophysics Data System (ADS)

    Akashi, Takuya; Wakasa, Yuji; Tanaka, Kanya; Karungaru, Stephen; Fukumi, Minoru

    The purpose of this study is to develop an interactive interface using eye movement to operate a welfare apparatus, such as a feeding device for an orthopedically-impaired person. A part of the purpose is to eliminate special calibration and re-calibration during the operation. Originalities of this proposed system are as follows: eye sensing with evolutionary processing and interactive operation screen based on some physiological knowledge. The proposed system uses a non-contact type interface by the eye movement. An iris is tracked and eye movement is measured by the evolutionary eye sensing (EES) method. An operation screen is divided into 9 areas, which has visual stimulation using the physiological knowledge. A user can select these areas by eye movement and decide by eye fixation. The effectiveness of the proposed system is evaluated by comparison experiments with 20 subjects. The results indicate that the proposed system is easy to use for first-timer, who can become proficient in operation just after a few exercises.

  11. Arthropod eye-inspired digital camera with unique imaging characteristics

    NASA Astrophysics Data System (ADS)

    Xiao, Jianliang; Song, Young Min; Xie, Yizhu; Malyarchuk, Viktor; Jung, Inhwa; Choi, Ki-Joong; Liu, Zhuangjian; Park, Hyunsung; Lu, Chaofeng; Kim, Rak-Hwan; Li, Rui; Crozier, Kenneth B.; Huang, Yonggang; Rogers, John A.

    2014-06-01

    In nature, arthropods have a remarkably sophisticated class of imaging systems, with a hemispherical geometry, a wideangle field of view, low aberrations, high acuity to motion and an infinite depth of field. There are great interests in building systems with similar geometries and properties due to numerous potential applications. However, the established semiconductor sensor technologies and optics are essentially planar, which experience great challenges in building such systems with hemispherical, compound apposition layouts. With the recent advancement of stretchable optoelectronics, we have successfully developed strategies to build a fully functional artificial apposition compound eye camera by combining optics, materials and mechanics principles. The strategies start with fabricating stretchable arrays of thin silicon photodetectors and elastomeric optical elements in planar geometries, which are then precisely aligned and integrated, and elastically transformed to hemispherical shapes. This imaging device demonstrates nearly full hemispherical shape (about 160 degrees), with densely packed artificial ommatidia. The number of ommatidia (180) is comparable to those of the eyes of fire ants and bark beetles. We have illustrated key features of operation of compound eyes through experimental imaging results and quantitative ray-tracing-based simulations. The general strategies shown in this development could be applicable to other compound eye devices, such as those inspired by moths and lacewings (refracting superposition eyes), lobster and shrimp (reflecting superposition eyes), and houseflies (neural superposition eyes).

  12. Visible-spectrum remote eye tracker for gaze communication

    NASA Astrophysics Data System (ADS)

    Imabuchi, Takashi; Prima, Oky Dicky A.; Kikuchi, Hikaru; Horie, Yusuke; Ito, Hisayoshi

    2015-03-01

    Many approaches have been proposed to create an eye tracker based on visible-spectrum. These efforts provide a possibility to create inexpensive eye tracker capable to operate outdoor. Although the resulted tracking accuracy is acceptable for a visible-spectrum head-mounted eye tracker, there are many limitations of these approaches to create a remote eye tracker. In this study, we propose a high-accuracy remote eye tracker that uses visible-spectrum imaging and several gaze communication interfaces suited to the tracker. The gaze communication interfaces are designed to assist people with motor disability. Our results show that the proposed eye tracker achieved an average accuracy of 0.77° and a frame rate of 28 fps with a personal computer. With a tablet device, the proposed eye tracker achieved an average accuracy of 0.82° and a frame rate of 25 fps. The proposed gaze communication interfaces enable users to type a complete sentence containing eleven Japanese characters in about a minute.

  13. Childhood Eye Diseases and Conditions

    MedlinePlus

    ... and Conditions Nov. 01, 2013 The importance of vision screening There are many eye conditions and diseases ... child’s vision. Focus and alignment disorders that affect vision If any of the following conditions is suspected, ...

  14. Genetic Testing and Eye Disease

    MedlinePlus

    ... a History of Eye Disease, Do You Need Genetic Testing? Mar. 23, 2012 Thanks to news coverage, ... of breast or ovarian cancer. Physicians now use genetic tests to decide on treatment for some types ...

  15. Applications of lobster eye optics

    NASA Astrophysics Data System (ADS)

    Hudec, R.; Pina, L.; Inneman, A.; Tichy, V.

    2015-05-01

    Applications of wide field Lobster Eye X ray telescopes are presented and discussed. The wide field X ray optics was originally proposed for use in X-ray astronomy, but there are numerous other application areas as well.

  16. Conjunctivitis (Pink Eye) in Newborns

    MedlinePlus

    ... Antibiotics Work Adenovirus Non-Polio Enterovirus Parent Portal Conjunctivitis (Pink Eye) in Newborns Language: English Español (Spanish) ... can be very serious. Symptoms and Causes of Conjunctivitis in Newborns Newborns with conjunctivitis develop drainage from ...

  17. Eye movements when viewing advertisements

    PubMed Central

    Higgins, Emily; Leinenger, Mallorie; Rayner, Keith

    2013-01-01

    In this selective review, we examine key findings on eye movements when viewing advertisements. We begin with a brief, general introduction to the properties and neural underpinnings of saccadic eye movements. Next, we provide an overview of eye movement behavior during reading, scene perception, and visual search, since each of these activities is, at various times, involved in viewing ads. We then review the literature on eye movements when viewing print ads and warning labels (of the kind that appear on alcohol and tobacco ads), before turning to a consideration of advertisements in dynamic media (television and the Internet). Finally, we propose topics and methodological approaches that may prove to be useful in future research. PMID:24672500

  18. Head and eye Echoencephalogram (image)

    MedlinePlus

    ... to test for abnormalities in the eye. The ultrasound helps evaluate the farthest part of the eyeball when there are cataracts. The test may help diagnose retinal detachment or other disorders and evaluate orbital lesions and intraocular lesions.

  19. Eye movement analysis: reading and moving target pursuit.

    PubMed

    Black, J L

    1984-01-01

    The design and application of an extensive and general software-based system for the study and analysis of eye movements in human subjects is described. The system can find application in a number of specialties in medicine, particularly clinical neurophysiology, as well as in studies of eye movement dynamics, including reading dynamics, in dyslexia. It is designed to run on the PDP 11 family of computers with standard peripherals and operating under the RT 11 executive.

  20. Actin-based vesicular transport in the first 20 min after dusk is crucial for daily rhabdom synthesis in the compound eye of the grapsid crab Hemigrapsus sanguineus.

    PubMed

    Matsushita, A; Arikawa, K

    1997-09-01

    In the crab Hemigrapsus sanguineus, maintained under a 12 h:12 h light:dark cycle, the amount of vesicular smooth endoplasmic reticulum (vesicular sER) in the photoreceptor cell body increases after the light is turned off. This paper demonstrates that actin filaments in the photoreceptor cell body are involved in the transport of vesicular sER towards the rhabdom. To specify the time of actin contribution to rhabdom synthesis, we disrupted the organization of actin filaments in the cell body with cytochalasin D at various time around dusk. We then measured the rhabdom size and also examined the ultrastructure of the photoreceptor cell body 3 h after extinguishing the light. When cytochalasin D was applied from either 1 h before or immediately after extinguishing the light, the rhabdom size did not increase, whereas vesicular sER accumulated in the cell body. In contrast, cytochalasin D applied to the eyes from 20 min after turning the light off did not inhibit rhabdom synthesis. These results indicate that the first 20 min after the light is turned off is particularly important for the transport of vesicular sER towards the rhabdom by the cell body actin filaments.

  1. 'By seeing with our own eyes, it can remain in our mind': qualitative evaluation findings suggest the ability of participatory video to reduce gender-based violence in conflict-affected settings.

    PubMed

    Gurman, Tilly A; Trappler, Regan M; Acosta, Angela; McCray, Pamella A; Cooper, Chelsea M; Goodsmith, Lauren

    2014-08-01

    Gender-based violence is pervasive and poses unique challenges in conflict-affected settings, with women and girls particularly vulnerable to its sequelae. Furthermore, widespread stigmatization of gender-based violence promotes silence among survivors and families, inhibiting access to services. Little evidence exists regarding effective gender-based violence prevention interventions in these settings. Through Our Eyes, a multi-year participatory video project, addressed gender-based violence by stimulating community dialogue and action in post-conflict settings in South Sudan, Uganda, Thailand, Liberia and Rwanda. The present qualitative analysis of project evaluation data included transcripts from 18 focus group discussions (n = 125) and key informant interviews (n = 76). Study participants included project team members, representatives from partner agencies, service providers and community members who either participated in video production or attended video screenings. Study findings revealed that the video project contributed to a growing awareness of women's rights and gender equality. The community dialogue helped to begin dismantling the culture of silence gender-based violence, encouraging survivors to access health and law enforcement services. Furthermore, both men and women reported attitude and behavioral changes related to topics such as wife beating, gender-based violence reporting and girls' education. Health education professionals should employ participatory video to address gender-based violence within conflict-affected settings.

  2. 'By seeing with our own eyes, it can remain in our mind': qualitative evaluation findings suggest the ability of participatory video to reduce gender-based violence in conflict-affected settings.

    PubMed

    Gurman, Tilly A; Trappler, Regan M; Acosta, Angela; McCray, Pamella A; Cooper, Chelsea M; Goodsmith, Lauren

    2014-08-01

    Gender-based violence is pervasive and poses unique challenges in conflict-affected settings, with women and girls particularly vulnerable to its sequelae. Furthermore, widespread stigmatization of gender-based violence promotes silence among survivors and families, inhibiting access to services. Little evidence exists regarding effective gender-based violence prevention interventions in these settings. Through Our Eyes, a multi-year participatory video project, addressed gender-based violence by stimulating community dialogue and action in post-conflict settings in South Sudan, Uganda, Thailand, Liberia and Rwanda. The present qualitative analysis of project evaluation data included transcripts from 18 focus group discussions (n = 125) and key informant interviews (n = 76). Study participants included project team members, representatives from partner agencies, service providers and community members who either participated in video production or attended video screenings. Study findings revealed that the video project contributed to a growing awareness of women's rights and gender equality. The community dialogue helped to begin dismantling the culture of silence gender-based violence, encouraging survivors to access health and law enforcement services. Furthermore, both men and women reported attitude and behavioral changes related to topics such as wife beating, gender-based violence reporting and girls' education. Health education professionals should employ participatory video to address gender-based violence within conflict-affected settings. PMID:24973224

  3. Eye-voice-controlled interface

    NASA Technical Reports Server (NTRS)

    Glenn, Floyd A., III; Iavecchia, Helene P.; Ross, Lorna V.; Stokes, James M.; Weiland, William J.

    1986-01-01

    The Ocular Attention-Sensing Interface System (OASIS) is an innovative human-computer interface which utilizes eye movement and voice commands to communicate messages between the operator and the system. This report initially describes some technical issues relevant to the development of such an interface. The results of preliminary experiments which evaluate alternative eye processing algorithms and feedback techniques are presented. Candidate interface applications are also discussed.

  4. The Cat's Eye Nebula

    NASA Technical Reports Server (NTRS)

    1994-01-01

    This NASA Hubble Space Telescope image shows one of the most complex planetary nebulae ever seen, NGC 6543, nicknamed the 'Cat's Eye Nebula.' Hubble reveals surprisingly intricate structures including concentric gas shells, jets of high-speed gas and unusual shock-induced knots of gas. Estimated to be 1,000 years old, the nebula is a visual 'fossil record' of the dynamics and late evolution of a dying star. A preliminary interpretation suggests that the star might be a double-star system. The suspected companion star also might be responsible for a pair of high-speed jets of gas that lie at right angles to this equatorial ring. If the companion were pulling in material from a neighboring star, jets escaping along the companion's rotation axis could be produced. These jets would explain several puzzling features along the periphery of the gas lobes. Like a stream of water hitting a sand pile, the jets compress gas ahead of them, creating the 'curlicue' features and bright arcs near the outer edge of the lobes. The twin jets are now pointing in different directions than these features. This suggests the jets are wobbling, or precessing, and turning on and off episodically. This color picture, taken with the Wide Field Planetary Camera-2, is a composite of three images taken at different wavelengths. (red, hydrogen-alpha; blue, neutral oxygen, 6300 angstroms; green, ionized nitrogen, 6584 angstroms). The image was taken on September 18, 1994. NGC 6543 is 3,000 light- years away in the northern constellation Draco. The term planetary nebula is a misnomer; dying stars create these cocoons when they lose outer layers of gas. The process has nothing to do with planet formation, which is predicted to happen early in a star's life.

  5. Eye Gaze Tracking using Correlation Filters

    SciTech Connect

    Karakaya, Mahmut; Boehnen, Chris Bensing; Bolme, David S; Mahallesi, Mevlana; Kayseri, Talas

    2014-01-01

    In this paper, we studied a method for eye gaze tracking that provide gaze estimation from a standard webcam with a zoom lens and reduce the setup and calibration requirements for new users. Specifically, we have developed a gaze estimation method based on the relative locations of points on the top of the eyelid and eye corners. Gaze estimation method in this paper is based on the distances between top point of the eyelid and eye corner detected by the correlation filters. Advanced correlation filters were found to provide facial landmark detections that are accurate enough to determine the subjects gaze direction up to angle of approximately 4-5 degrees although calibration errors often produce a larger overall shift in the estimates. This is approximately a circle of diameter 2 inches for a screen that is arm s length from the subject. At this accuracy it is possible to figure out what regions of text or images the subject is looking but it falls short of being able to determine which word the subject has looked at.

  6. Eye gaze tracking using correlation filters

    NASA Astrophysics Data System (ADS)

    Karakaya, Mahmut; Bolme, David; Boehnen, Chris

    2014-03-01

    In this paper, we studied a method for eye gaze tracking that provide gaze estimation from a standard webcam with a zoom lens and reduce the setup and calibration requirements for new users. Specifically, we have developed a gaze estimation method based on the relative locations of points on the top of the eyelid and eye corners. Gaze estimation method in this paper is based on the distances between top point of the eyelid and eye corner detected by the correlation filters. Advanced correlation filters were found to provide facial landmark detections that are accurate enough to determine the subjects gaze direction up to angle of approximately 4-5 degrees although calibration errors often produce a larger overall shift in the estimates. This is approximately a circle of diameter 2 inches for a screen that is arm's length from the subject. At this accuracy it is possible to figure out what regions of text or images the subject is looking but it falls short of being able to determine which word the subject has looked at.

  7. Eye complaints in the office environment: precorneal tear film integrity influenced by eye blinking efficiency

    PubMed Central

    Wolkoff, P; Nojgaard, J; Troiano, P; Piccoli, B

    2005-01-01

    To achieve a common base for understanding work related eye complaints in the office environment, it is necessary to merge approaches from indoor air science, occupational health, and ophthalmology. Based on database searches, it is concluded that precorneal tear film (PTF) alteration leads to eye complaints that may be caused by: (1) thermal factors (low relative humidity; high room temperature); (2) demanding task content (attention decreases blinking and widens the exposed ocular surface area); and (3) individual characteristics (for example, tear film alterations, blinking anomalies, gland dysfunctions, and use of contact lenses). These factors and conditions are able to progressively increase water evaporation and faster thinning of the PTF, which causes dryness and dry spot formation on the cornea, possibly followed by corneal and conjunctiva epithelial alterations and eye complaints. Another possible cause of eye complaints is certain irritating chemical compounds, in addition to oxidation mixtures that are formed in reactions between ozone and unsaturated organic compounds (alkenes). The effect may be exacerbated by low relative humidity. PMID:15613602

  8. Eye Movements in Risky Choice

    PubMed Central

    Hermens, Frouke; Matthews, William J.

    2015-01-01

    Abstract We asked participants to make simple risky choices while we recorded their eye movements. We built a complete statistical model of the eye movements and found very little systematic variation in eye movements over the time course of a choice or across the different choices. The only exceptions were finding more (of the same) eye movements when choice options were similar, and an emerging gaze bias in which people looked more at the gamble they ultimately chose. These findings are inconsistent with prospect theory, the priority heuristic, or decision field theory. However, the eye movements made during a choice have a large relationship with the final choice, and this is mostly independent from the contribution of the actual attribute values in the choice options. That is, eye movements tell us not just about the processing of attribute values but also are independently associated with choice. The pattern is simple—people choose the gamble they look at more often, independently of the actual numbers they see—and this pattern is simpler than predicted by decision field theory, decision by sampling, and the parallel constraint satisfaction model. © 2015 The Authors. Journal of Behavioral Decision Making published by John Wiley & Sons Ltd. PMID:27522985

  9. Eye casualty services in London

    PubMed Central

    Smith, H B; Daniel, C S; Verma, S

    2013-01-01

    The combined pressures of the European Working Time Directive, 4 h waiting time target, and growing rates of unplanned hospital attendances have forced a major consolidation of eye casualty departments across the country, with the remaining units seeing a rapid increase in demand. We examine the effect of these changes on the provision of emergency eye care in Central London, and see what wider lessons can be learned. We surveyed the managers responsible for each of London's 8 out-of-hours eye casualty services, analysed data on attendance numbers, and conducted detailed interviews with lead clinicians. At London's two largest units, Moorfields Eye Hospital and the Western Eye Hospital, annual attendance numbers have been rising at 7.9% per year (to 76 034 patients in 2010/11) and 9.6% per year (to 31 128 patients in 2010/11), respectively. Using Moorfields as a case study, we discuss methods to increase capacity and efficiency in response to this demand, and also examine some of the unintended consequences of service consolidation including patients travelling long distances to geographically inappropriate units, and confusion over responsibility for out-of-hours inpatient cover. We describe a novel ‘referral pathway' developed to minimise unnecessary travelling and delay for patients, and propose a forum for the strategic planning of London's eye casualty services in the future. PMID:23370420

  10. Autofluorescence spectroscopy for early diagnosis of cancer eye

    NASA Astrophysics Data System (ADS)

    Majumder, Shovan K.; Ghosh, Nirmalya; Rathod, Sopan M.; Gupta, Pradeep K.

    2007-02-01

    We report an in-vitro autofluorescence spectroscopic study of cow eye tissue to explore the applicability of the approach in discriminating early stage "cancer eye" from normal squamous eye tissues. Significant differences were observed in the autofluorescence signatures between the "cancer eye" and normal eye tissues. The spectral differences were quantified by employing a probability-based diagnostic algorithm developed based on recently formulated theory of Relevance Vector Machine (RVM), a Bayesian machine-learning framework of statistical pattern recognition. The algorithm provided sensitivity and specificity values of 97 +/- 2% towards cancer for the training set data based on leave-one-out cross validation and a sensitivity of 97 +/- 2% and a specificity of 99 +/- 1% towards cancer for the independent validation set data. These results suggest that autofluorescence spectroscopy might prove to be a quantitative in-vivo diagnostic modality for early and accurate diagnosis of "cancer eye" in veterinary clinical setting, which would help improve ranch management from both economic and animal care standpoint.

  11. What's on TV? Detecting age-related neurodegenerative eye disease using eye movement scanpaths

    PubMed Central

    Crabb, David P.; Smith, Nicholas D.; Zhu, Haogang

    2014-01-01

    Purpose: We test the hypothesis that age-related neurodegenerative eye disease can be detected by examining patterns of eye movement recorded whilst a person naturally watches a movie. Methods: Thirty-two elderly people with healthy vision (median age: 70, interquartile range [IQR] 64–75 years) and 44 patients with a clinical diagnosis of glaucoma (median age: 69, IQR 63–77 years) had standard vision examinations including automated perimetry. Disease severity was measured using a standard clinical measure (visual field mean deviation; MD). All study participants viewed three unmodified TV and film clips on a computer set up incorporating the Eyelink 1000 eyetracker (SR Research, Ontario, Canada). Eye movement scanpaths were plotted using novel methods that first filtered the data and then generated saccade density maps. Maps were then subjected to a feature extraction analysis using kernel principal component analysis (KPCA). Features from the KPCA were then classified using a standard machine based classifier trained and tested by a 10-fold cross validation which was repeated 100 times to estimate the confidence interval (CI) of classification sensitivity and specificity. Results: Patients had a range of disease severity from early to advanced (median [IQR] right eye and left eye MD was −7 [−13 to −5] dB and −9 [−15 to −4] dB, respectively). Average sensitivity for correctly identifying a glaucoma patient at a fixed specificity of 90% was 79% (95% CI: 58–86%). The area under the Receiver Operating Characteristic curve was 0.84 (95% CI: 0.82–0.87). Conclusions: Huge data from scanpaths of eye movements recorded whilst people freely watch TV type films can be processed into maps that contain a signature of vision loss. In this proof of principle study we have demonstrated that a group of patients with age-related neurodegenerative eye disease can be reasonably well separated from a group of healthy peers by considering these eye movement

  12. Further development of forensic eye color predictive tests.

    PubMed

    Ruiz, Y; Phillips, C; Gomez-Tato, A; Alvarez-Dios, J; Casares de Cal, M; Cruz, R; Maroñas, O; Söchtig, J; Fondevila, M; Rodriguez-Cid, M J; Carracedo, A; Lareu, M V

    2013-01-01

    In forensic analysis predictive tests for external visible characteristics (or EVCs), including inference of iris color, represent a potentially useful tool to guide criminal investigations. Two recent studies, both focused on forensic testing, have analyzed single nucleotide polymorphism (SNP) genotypes underlying common eye color variation (Mengel-From et al., Forensic Sci. Int. Genet. 4:323 and Walsh et al., Forensic Sci. Int. Genet. 5:170). Each study arrived at different recommendations for eye color predictive tests aiming to type the most closely associated SNPs, although both confirmed rs12913832 in HERC2 as the key predictor, widely recognized as the most strongly associated marker with blue and brown iris colors. Differences between these two studies in identification of other eye color predictors may partly arise from varying approaches to assigning phenotypes, notably those not unequivocally blue or dark brown and therefore occupying an intermediate iris color continuum. We have developed two single base extension assays typing 37 SNPs in pigmentation-associated genes to study SNP-genotype based prediction of eye, skin, and hair color variation. These assays were used to test the performance of different sets of eye color predictors in 416 subjects from six populations of north and south Europe. The presence of a complex and continuous range of intermediate phenotypes distinct from blue and brown eye colors was confirmed by establishing eye color populations compared to genetic clusters defined using Structure software. Our study explored the effect of an expanded SNP combination beyond six markers has on the ability to predict eye color in a forensic test without extending the SNP assay excessively - thus maintaining a balance between the test's predictive value and an ability to reliably type challenging DNA with a multiplex of manageable size. Our evaluation used AUC analysis (area under the receiver operating characteristic curves) and na

  13. 14 CFR 67.103 - Eye.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 2 2013-01-01 2013-01-01 false Eye. 67.103 Section 67.103 Aeronautics and... AND CERTIFICATION First-Class Airman Medical Certificate § 67.103 Eye. Eye standards for a first-class airman medical certificate are: (a) Distant visual acuity of 20/20 or better in each eye separately,...

  14. 14 CFR 67.303 - Eye.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 2 2013-01-01 2013-01-01 false Eye. 67.303 Section 67.303 Aeronautics and... AND CERTIFICATION Third-Class Airman Medical Certificate § 67.303 Eye. Eye standards for a third-class airman medical certificate are: (a) Distant visual acuity of 20/40 or better in each eye separately,...

  15. 21 CFR 886.3200 - Artificial eye.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Artificial eye. 886.3200 Section 886.3200 Food and... OPHTHALMIC DEVICES Prosthetic Devices § 886.3200 Artificial eye. (a) Identification. An artificial eye is a device resembling the anterior portion of the eye, usually made of glass or plastic, intended to...

  16. 21 CFR 886.3200 - Artificial eye.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Artificial eye. 886.3200 Section 886.3200 Food and... OPHTHALMIC DEVICES Prosthetic Devices § 886.3200 Artificial eye. (a) Identification. An artificial eye is a device resembling the anterior portion of the eye, usually made of glass or plastic, intended to...

  17. 21 CFR 886.3200 - Artificial eye.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Artificial eye. 886.3200 Section 886.3200 Food and... OPHTHALMIC DEVICES Prosthetic Devices § 886.3200 Artificial eye. (a) Identification. An artificial eye is a device resembling the anterior portion of the eye, usually made of glass or plastic, intended to...

  18. 21 CFR 886.3200 - Artificial eye.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Artificial eye. 886.3200 Section 886.3200 Food and... OPHTHALMIC DEVICES Prosthetic Devices § 886.3200 Artificial eye. (a) Identification. An artificial eye is a device resembling the anterior portion of the eye, usually made of glass or plastic, intended to...

  19. 21 CFR 886.3200 - Artificial eye.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Artificial eye. 886.3200 Section 886.3200 Food and... OPHTHALMIC DEVICES Prosthetic Devices § 886.3200 Artificial eye. (a) Identification. An artificial eye is a device resembling the anterior portion of the eye, usually made of glass or plastic, intended to...

  20. 14 CFR 67.303 - Eye.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 2 2012-01-01 2012-01-01 false Eye. 67.303 Section 67.303 Aeronautics and... AND CERTIFICATION Third-Class Airman Medical Certificate § 67.303 Eye. Eye standards for a third-class airman medical certificate are: (a) Distant visual acuity of 20/40 or better in each eye separately,...

  1. A New Method to Assess Eye Dominance

    ERIC Educational Resources Information Center

    Valle-Inclan, Fernando; Blanco, Manuel J.; Soto, David; Leiros, Luz

    2008-01-01

    People usually show a stable preference for one of their eyes when monocular viewing is required ("sighting dominance") or under dichoptic stimulation conditions ("sensory eye-dominance"). Current procedures to assess this "eye dominance" are prone to error. Here we present a new method that provides a continuous measure of eye dominance and…

  2. Contact Lens-Related Eye Infections

    MedlinePlus

    ... Stories Español Eye Health / Eye Health A-Z Contact Lens-Related Eye Infections Sections Contact Lens-Related ... About Contact Lenses Proper Care of Contact Lenses Contact Lens-Related Eye Infections Written by: Kierstan Boyd ...

  3. Effects of eye color on frisbee toss.

    PubMed

    Beer, J; Fleming, P

    1988-04-01

    Light-eyed individuals generally perform better at self-paced activities while dark-eyed individuals perform better at reactive activities. Using multiple regression it was found that dark-eyed students hit a target with a frisbee more times than did light-eyed students.

  4. A new amplicon based approach of whole mitogenome sequencing for phylogenetic and phylogeographic analysis: An example of East African white-eyes (Aves, Zosteropidae).

    PubMed

    Meimberg, Harald; Schachtler, Christina; Curto, Manuel; Husemann, Martin; Habel, Jan Christian

    2016-09-01

    Classical Sanger sequencing is still frequently used to generate sequence data for phylogenetic and phylogeographic inference. In this contribution we present a novel approach to genotype whole mitogenomic haplotypes using Illumina MiSeq reads from indexed amplicons. Our new approach reduces preparation time by multiplexing loci within a single or few PCR reactions and by plate format library construction. The use of paired-end reads allows covering amplicons of about 0.5kb and thus no nebulisation and assembly are necessary. We tested the power and effectiveness of this technique by analysing the mitogenomic diversity of East African white-eye bird species (Zosteropidae), a taxonomically highly diverse and complex species flock found in various ecosystems spread across major parts of Africa. We compare the newly generated mitogenomic data set with published data of three mitochondrial genes for a similar set of populations and taxa. The comparison demonstrates that our new procedure represents a cost effective use of NGS for medium throughput phylogenetic analyses. Using this method, we were able to increase the amount of phylogenetic information significantly, while reducing the costs and effort in the laboratory. The mitogenomic data show a higher resolution than previous studies providing higher support and new insights in the relationships of Zosterops species. Our data suggest to split Z. poliogaster into four distinct species, three of which had previously been proposed: Z. silvanus, Z. mbulensis, Z. kikyuensis and Z. kulalensis. Our approach allows the genotyping of whole mitogenomes for a large number of individuals and thus allows more reliable reconstruction of phylogenetic and phylogeographic relationships - also for non-model organisms. PMID:27233440

  5. Understanding eye movements in face recognition using hidden Markov models.

    PubMed

    Chuk, Tim; Chan, Antoni B; Hsiao, Janet H

    2014-09-16

    We use a hidden Markov model (HMM) based approach to analyze eye movement data in face recognition. HMMs are statistical models that are specialized in handling time-series data. We conducted a face recognition task with Asian participants, and model each participant's eye movement pattern with an HMM, which summarized the participant's scan paths in face recognition with both regions of interest and the transition probabilities among them. By clustering these HMMs, we showed that participants' eye movements could be categorized into holistic or analytic patterns, demonstrating significant individual differences even within the same culture. Participants with the analytic pattern had longer response times, but did not differ significantly in recognition accuracy from those with the holistic pattern. We also found that correct and wrong recognitions were associated with distinctive eye movement patterns; the difference between the two patterns lies in the transitions rather than locations of the fixations alone.

  6. The perception of heading during eye movements

    NASA Technical Reports Server (NTRS)

    Royden, Constance S.; Banks, Martin S.; Crowell, James A.

    1992-01-01

    Warren and Hannon (1988, 1990), while studying the perception of heading during eye movements, concluded that people do not require extraretinal information to judge heading with eye/head movements present. Here, heading judgments are examined at higher, more typical eye movement velocities than the extremely slow tracking eye movements used by Warren and Hannon. It is found that people require extraretinal information about eye position to perceive heading accurately under many viewing conditions.

  7. [Incidence of sports-related eye injuries].

    PubMed

    Pikkel, J; Gelfand, Y; Miller, B

    1995-10-01

    The incidence of sports-related eye injuries was analyzed retrospectively for 1991-1993. It was fairly steady at about 2% of all eye casualties annually. 21% of those with sports-related eye injuries required hospitalization. The commonest pathological findings were corneal erosion (32%), eye lid injuries (27%), hyphema (19%) and macular edema (3%). Most eyes were injured during soccer (37%) and basketball (27%) games, the most popular sports in Israel.

  8. Eye movements reset visual perception.

    PubMed

    Paradiso, Michael A; Meshi, Dar; Pisarcik, Jordan; Levine, Samuel

    2012-12-12

    Human vision uses saccadic eye movements to rapidly shift the sensitive foveal portion of our retina to objects of interest. For vision to function properly amidst these ballistic eye movements, a mechanism is needed to extract discrete percepts on each fixation from the continuous stream of neural activity that spans fixations. The speed of visual parsing is crucial because human behaviors ranging from reading to driving to sports rely on rapid visual analysis. We find that a brain signal associated with moving the eyes appears to play a role in resetting visual analysis on each fixation, a process that may aid in parsing the neural signal. We quantified the degree to which the perception of tilt is influenced by the tilt of a stimulus on a preceding fixation. Two key conditions were compared, one in which a saccade moved the eyes from one stimulus to the next and a second simulated saccade condition in which the stimuli moved in the same manner but the subjects did not move their eyes. We find that there is a brief period of time at the start of each fixation during which the tilt of the previous stimulus influences perception (in a direction opposite to the tilt aftereffect)--perception is not instantaneously reset when a fixation starts. Importantly, the results show that this perceptual bias is much greater, with nearly identical visual input, when saccades are simulated. This finding suggests that, in real-saccade conditions, some signal related to the eye movement may be involved in the reset phenomenon. While proprioceptive information from the extraocular muscles is conceivably a factor, the fast speed of the effect we observe suggests that a more likely mechanism is a corollary discharge signal associated with eye movement.

  9. Temporal integration in diseased eyes.

    PubMed

    Kono, M; Yamade, S

    We examined critical duration for visual acuity in eyes with central serous retinopathy (CSR), macular edema (ME) and glaucoma. Critical duration for visual acuity is the minimum period of time to perceive the acuity chart of his best. Visual acuity was measured at several limited exposure durations and the results were then compared with that of normal eyes. The acuity target was a single Landolt ring. The size, direction, and exposure duration of the target were computer controlled. The mean critical duration for visual acuity of the CSR and ME groups was 1.78 s and 2.69 s. These were significantly longer than that of the normal group (0.62 s). The critical duration of the glaucoma group was 0.42 s, which was not significantly prolonged. Critical duration for the increment or static threshold was measured for the purpose of comparison, and no significant differences were found between the diseased eyes (the CSR and ME groups) and the normal eyes, although the thresholds were significantly higher in the diseased eyes. Next, fixation movements which occurred during visual acuity testing were observed in order to investigate their role in acuity testing. In both normal and ME eyes the frequency and amplitude of microsaccades were smaller while the visual acity chart was shown. This suggests that microsaccades play no positive role in the reading of acuity charts, and that they bear little relation to the phenomenon of critical duration for visual acuity. From these results we hypothesized that in the CSR and ME groups the X-type ganglion cells send incomplete information to the central neural system. Thus, a longer time is required to obtain complete information before responding. Furthermore, one glaucoma case suggested that in diseased eyes in which mainly the Y-cell systems are damaged, temporal specificity in visual acuity for shorter exposure duration may reveal different response patterns. PMID:9112193

  10. Temporal integration in diseased eyes.

    PubMed

    Kono, M; Yamade, S

    We examined critical duration for visual acuity in eyes with central serous retinopathy (CSR), macular edema (ME) and glaucoma. Critical duration for visual acuity is the minimum period of time to perceive the acuity chart of his best. Visual acuity was measured at several limited exposure durations and the results were then compared with that of normal eyes. The acuity target was a single Landolt ring. The size, direction, and exposure duration of the target were computer controlled. The mean critical duration for visual acuity of the CSR and ME groups was 1.78 s and 2.69 s. These were significantly longer than that of the normal group (0.62 s). The critical duration of the glaucoma group was 0.42 s, which was not significantly prolonged. Critical duration for the increment or static threshold was measured for the purpose of comparison, and no significant differences were found between the diseased eyes (the CSR and ME groups) and the normal eyes, although the thresholds were significantly higher in the diseased eyes. Next, fixation movements which occurred during visual acuity testing were observed in order to investigate their role in acuity testing. In both normal and ME eyes the frequency and amplitude of microsaccades were smaller while the visual acity chart was shown. This suggests that microsaccades play no positive role in the reading of acuity charts, and that they bear little relation to the phenomenon of critical duration for visual acuity. From these results we hypothesized that in the CSR and ME groups the X-type ganglion cells send incomplete information to the central neural system. Thus, a longer time is required to obtain complete information before responding. Furthermore, one glaucoma case suggested that in diseased eyes in which mainly the Y-cell systems are damaged, temporal specificity in visual acuity for shorter exposure duration may reveal different response patterns.

  11. Eye movements reset visual perception.

    PubMed

    Paradiso, Michael A; Meshi, Dar; Pisarcik, Jordan; Levine, Samuel

    2012-01-01

    Human vision uses saccadic eye movements to rapidly shift the sensitive foveal portion of our retina to objects of interest. For vision to function properly amidst these ballistic eye movements, a mechanism is needed to extract discrete percepts on each fixation from the continuous stream of neural activity that spans fixations. The speed of visual parsing is crucial because human behaviors ranging from reading to driving to sports rely on rapid visual analysis. We find that a brain signal associated with moving the eyes appears to play a role in resetting visual analysis on each fixation, a process that may aid in parsing the neural signal. We quantified the degree to which the perception of tilt is influenced by the tilt of a stimulus on a preceding fixation. Two key conditions were compared, one in which a saccade moved the eyes from one stimulus to the next and a second simulated saccade condition in which the stimuli moved in the same manner but the subjects did not move their eyes. We find that there is a brief period of time at the start of each fixation during which the tilt of the previous stimulus influences perception (in a direction opposite to the tilt aftereffect)--perception is not instantaneously reset when a fixation starts. Importantly, the results show that this perceptual bias is much greater, with nearly identical visual input, when saccades are simulated. This finding suggests that, in real-saccade conditions, some signal related to the eye movement may be involved in the reset phenomenon. While proprioceptive information from the extraocular muscles is conceivably a factor, the fast speed of the effect we observe suggests that a more likely mechanism is a corollary discharge signal associated with eye movement. PMID:23241264

  12. Effects of a nutraceutical formulation based on the combination of antioxidants and ω-3 essential fatty acids in the expression of inflammation and immune response mediators in tears from patients with dry eye disorders

    PubMed Central

    Pinazo-Durán, Maria D; Galbis-Estrada, Carmen; Pons-Vázquez, Sheila; Cantú-Dibildox, Jorge; Marco-Ramírez, Carla; Benítez-del-Castillo, Javier

    2013-01-01

    Background Women, and those older than 65 years of age, are particularly susceptible to dry eye disorders (DEDs). Inflammation is clearly involved in the pathogenesis of DEDs, and there is mounting evidence on the antioxidant and antiinflammatory properties of essential polyunsaturated fatty acids (EPUFAs). Objective To analyze whether a combined formulation of antioxidants and long-chain EPUFAs may improve the evolution of DEDs. Methods We used a prospective study to address the relationship between risk factors, clinical outcomes, and expression levels of inflammation and immune response (IIR) mediators in human reflex tear samples. Participants included: (1) patients diagnosed with nonsevere DEDs (DED group [DEDG]); and (2) healthy controls (control group [CG]). Participants were randomly assigned to homogeneous subgroups according to daily oral intake (+S) or not (−NS) of antioxidants and long-chain EPUFAs for 3 months. After an interview and a systematized ophthalmic examination, reflex tears were collected simultaneously from both eyes; samples were later subjected to a multiplexed particle-based flow cytometry assay. A specific set of IIR mediators was analyzed. All data were statistically processed through the SPSS 15.0 software program. Results Significantly higher expressions of interleukin (IL)-1β, IL6, and IL10 and significantly lower vascular endothelial growth factor expressions were found in the DEDG as compared to the CG. In the DEDG, significant negative correlations were detected between the Schirmer test and IL-1β, IL6, IL8, and vascular endothelial growth factor levels, and between the fluorescein breakup time with IL6 and IL8 levels. However, levels of IL-1β, IL6, and IL10 in tears were significantly lower in the DEDG+S versus the DEDG−NS and in the CG+S versus the CG−NS. Subjective symptoms of dry eye significantly improved in the DEDG+S versus the DEDG−NS. Conclusion IIR mediators showed different expression patterns in DED

  13. Chance and necessity in eye evolution.

    PubMed

    Gehring, Walter J

    2011-01-01

    Charles Darwin has proposed the theory that evolution of live organisms is based on random variation and natural selection. Jacques Monod in his classic book Chance and Necessity, published 40 years ago, presented his thesis "that the biosphere does not contain a predictable class of objects or events, but constitutes a particular occurrence, compatible indeed with the first principles, but not deducible from those principals and therefore, essentially unpredictable." Recent discoveries in eye evolution are in agreement with both of these theses. They confirm Darwin's assumption of a simple eye prototype and lend strong support for the notion of a monophyletic origin of the various eye types. Considering the complexity of the underlying gene regulatory networks the unpredictability is obvious. The evolution of the Hox gene cluster and the specification of the body plan starting from an evolutionary prototype segment is discussed. In the course of evolution, a series of similar prototypic segments gradually undergoes cephalization anteriorly and caudalization posteriorly through diversification of the Hox genes.

  14. Eye shape illusions induced by eyebrow positions.

    PubMed

    Matsushita, Soyogu; Morikawa, Kazunori; Mitsuzane, Saya; Yamanami, Haruna

    2015-01-01

    We investigated whether the position of the eyebrows influences the perceived shape of the eyes by employing psychophysical measurements. Experiment 1 used arched and straight eyebrows at five different inclinations as stimuli and measured the perceived inclination of the eyes. The results demonstrated that the eyes are perceived to be somewhat inclined in the same direction as the eyebrows. Experiment 2 measured the perceived eye size by manipulating the distance between the eyes and the eyebrows and the curvature of the eyebrows across three levels. The results showed that the lower eyebrows (ie closer to eyes) made the eyes appear larger and the higher eyebrows made the eyes appear smaller, while eyebrow curvature had no effect on perceived eye size. Experiment 3 examined the role of the eye-eyebrow distance in the eye inclination illusion shown in experiment 1. The eye inclination illusion was unaffected by the eye-eyebrow distance, suggesting that the eye inclination illusion and the eye size illusion may involve different kinds of assimilation. These illusions are discussed in terms of face perception and possible practical applications.

  15. Can children with autism read emotions from the eyes? The eyes test revisited.

    PubMed

    Franco, Fabia; Itakura, Shoji; Pomorska, Krystyna; Abramowski, Anna; Nikaido, Kozue; Dimitriou, Dagmara

    2014-05-01

    This study aimed to test two new, simplified tasks related to the eye-test, targeting children with autism spectrum disorder (ASD) and typically developing controls (TD). Test-1 assessed the recognition of emotion/mental states with displays using one word and two eye-pictures, whereas Test-2 presented displays using two words and one eye-picture. Black and white photographs of children were used as materials. A cross-cultural study (Caucasian/East-Asian) with adults was initially carried out to verify generalizability across different ethnic groups. Cross-sectional trajectory analyses were used to compare emotion recognition from the eyes in the two tests. Trajectories were constructed linking performance on both tests either to chronological age or to different measures of mental age (receptive vocabulary based on the BPVS, CARS or ASQ for the ASD group). Performance improved with chronological age in both the ASD and TD groups of children. However, performance in Test-1 was significantly superior in children with ASD, who showed delayed onset and slower rate of improvement than TD children in Test-2. In both the ASD and TD groups the lowest error rate was recorded for the item 'anger', suggesting that threat-detection cue mechanisms may be intact in autism. In general, all children showed good performance on our novel tests, thus making them good candidates for assessing younger children and those with lower general abilities. PMID:24636022

  16. Image analysis and statistical evaluation of two-dimensional human eye retina images of healthy and glaucomatous eyes

    NASA Astrophysics Data System (ADS)

    Pluhacek, Frantisek; Pospisil, Jaroslav

    2003-11-01

    In this paper, a new automatic glaucoma diagnostics method which enables to determine the probability of glaucoma occurrence in a studied eye is described. This method is based on the computer image analysis of two-dimensional images of the blind spot of the human eye retina and on the successive statistical evaluation of the obtained data. First, the characteristic symptoms of glaucoma are shortly described. Next, a suitable numerical parameter of the retina blind spot is defined. The computer image analysis method of the automatic determination of the mentioned parameter is described and it is applied to a set of normal healthy eye images and to a set of glaucomatous eye images. The probability of glaucoma occurrence for each value of the introduced parameter is suitably defined and computed by virtue of the statistical evaluation of the obtained results.

  17. Eye movements in vestibular disorders.

    PubMed

    Kheradmand, A; Colpak, A I; Zee, D S

    2016-01-01

    The differential diagnosis of patients with vestibular symptoms usually begins with the question: is the lesion central or is it peripheral? The answer commonly emerges from a careful examination of eye movements, especially when the lesion is located in otherwise clinically silent areas of the brain such as the vestibular portions of the cerebellum (flocculus, paraflocculus which is called the tonsils in humans, nodulus, and uvula) and the vestibular nuclei as well as immediately adjacent areas (the perihypoglossal nuclei and the paramedian nuclei and tracts). The neural circuitry that controls vestibular eye movements is intertwined with a larger network within the brainstem and cerebellum that also controls other types of conjugate eye movements. These include saccades and pursuit as well as the mechanisms that enable steady fixation, both straight ahead and in eccentric gaze positions. Navigating through this complex network requires a thorough knowledge about all classes of eye movements to help localize lesions causing a vestibular disorder. Here we review the different classes of eye movements and how to examine them, and then describe common ocular motor findings associated with central vestibular lesions from both a topographic and functional perspective. PMID:27638066

  18. Indications for eye removal surgeries

    PubMed Central

    Koylu, Mehmet T.; Gokce, Gokcen; Uysal, Yusuf; Ceylan, Osman M.; Akıncıoglu, Dorukcan; Gunal, Armagan

    2015-01-01

    Objectives: To analyze the indications and types of eye removals at a military tertiary care hospital in Turkey. Methods: The medical records (age, gender, affected eye, type of surgical procedure, indications of surgery) of 123 patients who underwent evisceration and enucleation in the course of a 15-year period (January 2000 to December 2014) at Gulhane Military Medical Academy, Ankara, Turkey were reviewed retrospectively. Results: The mean age was 35.61±18.52 (range 3-80 years). The number of male in the patient group was 92 (74.8%) and female was 31 (25.2%). Patients who underwent evisceration were 95 (77.2%), whereas 28 (22.8%) of them underwent enucleation. The mean age of the eviscerated patients was 30.63±13.08, whereas the mean age of the enucleated patients was 52.50±23.92 (p<0.001). The leading indications for eye amputations were trauma (n=62, 50.4%), malignancy (n=20, 16.3%), painful blind eye and absolute glaucoma (n=20, 16.3%), endophthalmitis (n=12, 9.7%), and phthisis bulbi, and cosmetic reasons (n=9, 7.3%). Conclusion: Trauma was the most common etiology for evisceration, and malignancy was the most common etiology for enucleation. Using protective eyewear and early detection of intraocular malignancy and glaucoma through routine ophthalmic examinations are essential for providing non-invasive treatment modalities instead of eye removal. PMID:26446332

  19. How flies clean their eyes

    NASA Astrophysics Data System (ADS)

    Amador, Guillermo; Durand, Fabien; Mao, Wenbin; Alexeev, Alexander; Hu, David

    2013-11-01

    Flying insects face a barrage of foreign particles such as dust and pollen, which threaten to coat the insect's eyes and antennae, limiting their sensing abilities. In this study, we elucidate novel aerodynamic and elastic mechanisms by which insects keep these organs clean. The compound eye of many species of insects is covered by an array of short bristles, or setae, evenly spaced between each photoreceptor unit. Among these insect species, setae length is triple their spacing. We conduct numerical simulations and wind tunnel experiments using an insect eye mimic to show this critical setae length reduces shear rate at the eye surface by 80%. Thus, the setae create a stagnant zone in front of the eye, which diverts airflow to reduce deposition of particles. Setae can also act as springboards to catapult accumulated particles. In high speed videography of insects using their legs to clean themselves, we observe deflected setae hurling micron scale particles at accelerations over 100 times earth's gravity. The dual abilities of setae to divert airflow and catapult particles may motivate bio-inspired designs for dust-controlling lenses, sensors, and solar panels.

  20. Eye-Eye with Dr. Rachel Bishop | NIH MedlinePlus the Magazine

    MedlinePlus

    ... this page please turn JavaScript on. Feature: Glaucoma Eye-to-Eye with Dr. Rachel Bishop Past Issues / Spring 2015 ... new patient comes in because they scratched their eye while working in the yard, or they think ...

  1. 76 FR 63942 - Notice of Issuance of Final Determination Concerning a Surgical Mask With a Protective Eye Shield

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-14

    ... Mask With a Protective Eye Shield AGENCY: U.S. Customs and Border Protection, Department of Homeland... Surgical Mask with a Protective Eye Shield. Based upon the facts presented, CBP has concluded in the final determination that Turkey is the country of origin of the Surgical Mask with a Protective Eye Shield,...

  2. Tracking with the mind's eye

    NASA Technical Reports Server (NTRS)

    Krauzlis, R. J.; Stone, L. S.

    1999-01-01

    The two components of voluntary tracking eye-movements in primates, pursuit and saccades, are generally viewed as relatively independent oculomotor subsystems that move the eyes in different ways using independent visual information. Although saccades have long been known to be guided by visual processes related to perception and cognition, only recently have psychophysical and physiological studies provided compelling evidence that pursuit is also guided by such higher-order visual processes, rather than by the raw retinal stimulus. Pursuit and saccades also do not appear to be entirely independent anatomical systems, but involve overlapping neural mechanisms that might be important for coordinating these two types of eye movement during the tracking of a selected visual object. Given that the recovery of objects from real-world images is inherently ambiguous, guiding both pursuit and saccades with perception could represent an explicit strategy for ensuring that these two motor actions are driven by a single visual interpretation.

  3. Red eyes in renal failure.

    PubMed Central

    Klaassen-Broekema, N; van Bijsterveld, O P

    1992-01-01

    Of 57 patients with chronic renal failure who all had deposition of calcium salts in the conjunctival and corneal tissue two developed a brief episode of painful irritation and redness of the conjunctiva and subconjunctiva. This hyperaemia was adjacent to erosions of the corneal epithelium of the eye as a consequence of exfoliation of calcium concretions from the superficial corneal epithelium. Eight patients showed inflammatory reactions of the conjunctivae that were clinically identical to inflamed pingueculae. Three patients showed an inflammatory reaction of the eye that was characterised by a waxy red, more or less diffuse, episcleral and conjunctival hyperaemia extending beyond the palpebral fissure. The average value of the serum calcium concentration in these patients was particularly high and statistically significantly higher than in patients with calcification but without inflammatory signs and also higher than in patients who showed pingueculitis. We propose to reserve the term 'red eye of renal failure' for the latter group of patients. Images PMID:1390507

  4. Moving Ahead With Eye Power

    NASA Technical Reports Server (NTRS)

    2002-01-01

    NASA's Jet Propulsion Laboratory's collaborated with LC Technologies, Inc., to improve LCT's Eyegaze Communication System, an eye tracker that enables people with severe cerebral palsy, muscular dystrophy, multiple sclerosis, strokes, brain injuries, spinal cord injuries, and ALS (amyotrophic lateral sclerosis) to communicate and control their environment using their eye movements. To operate the system, the user sits in front of the computer monitor while the camera focuses on one eye. By looking at control keys on the monitor for a fraction of a second, the user can 'talk' with speech synthesis, type, operate a telephone, access the Internet and e-mail, and run computer software. Nothing is attached to the user's head or body, and the improved size and portability allow the system to be mounted on a wheelchair. LCT and JPL are working on several other areas of improvement that have commercial add-on potential.

  5. Aspectual coercion in eye movements.

    PubMed

    Townsend, David J

    2013-06-01

    Comprehension includes interpreting sentences in terms of aspectual categories such as processes (Harry climbed) and culminations (Harry reached the top). Adding a verbal modifier such as for many years to a culmination coerces its interpretation from one to many culminations. Previous studies have found that coercion increases lexical decision and meaning judgment time, but not eye fixation time. This study recorded eye movements as participants read sentences in which a coercive adverb increased the interpretation of multiple events. Adverbs appeared at the end of a clause and line; the post-adverb region appeared at the beginning of the next line; follow-up questions occasionally asked about aspectual meaning; and clause type varied systematically. Coercive adverbs increased eye fixation time in the post-adverb region and in the adverb and post-adverb regions combined. Factors that influence the appearance of aspectual coercion may include world knowledge, follow-up questions, and the location and ambiguity of adverbs.

  6. Determinants of Utilization of Eye Care Services in a Rural Adult Population of a Developing Country

    PubMed Central

    Olusanya, Bolutife A.; Ashaye, Adeyinka O.; Owoaje, Eme T.; Baiyeroju, Aderonke M.; Ajayi, Benedictus G.

    2016-01-01

    Purpose: To describe the factors that determine the utilization of eye care services in a rural community in South-Western Nigeria. Methods: A descriptive cross-sectional survey using a multistage sampling technique was conducted. The main outcome measure was self-reported previous consultation of an orthodox medical facility for eye care. Results: The study sample included 643 participants. Only 122 (19%) respondents had previously visited orthodox facilities in search of eye care and 24% of those with presenting visual acuity <6/18 had sought eye care. Characteristics associated with previous utilization of eye care services were age of =70 years (odds ratio [OR] ≥ 1.7, P = 0.02); male gender (OR = 1.5, P = 0.04); literacy (OR = 1.7, P = 0.007); and residing close to an eye care facility (OR = 2.8, P < 0.001). Blind respondents were three times more likely to seek eye care (P < 0.001). Regression analysis revealed that factors associated with increased likelihood of utilization of eye care services included age ≥70 years; literacy; residence close to an eye facility; being diabetic or hypertensive; history of ocular symptoms, and blindness. Conclusions: These findings suggest that a significant proportion (75%) of adults in the study area are not utilizing eye care services and that blindness is an important determinant of utilization of eye care services. Health education and awareness campaigns about the importance and benefits of seeking eye care early, and the provision of community-based eye care programs are essential to boost the uptake of eye care services in this community as well as other rural areas of West Africa. PMID:26957847

  7. Comparison of Dry Eye Parameters between Diabetics and Non-Diabetics in District of Kuantan, Pahang

    PubMed Central

    Aljarousha, Mohammed; Badarudin, Noor Ezailina; Che Azemin, Mohd Zulfaezal

    2016-01-01

    Introduction Diabetes may affect the human body’s systems and organs, including the eye. Diabetic retinopathy is the 5th leading cause of blindness globally. Diabetic subjects demonstrated dry eye symptoms that were also supported by the low values of the clinical tests. Purpose This study aimed to compare the dry eye symptoms and signs between diabetics and non-diabetics and tear functions between diabetic subjects with and without dry eye. Methods This retrospective study was based on the observation of 643 medical files. Using a convenience sampling method, 88 subjects were found to report diabetes mellitus. The information extracted from the files included: date of first examination, age at first visit, gender, past ocular history, systemic disease, symptoms of dry eye disease and details of clinical diagnostic signs. Non-contact lens wearers were excluded. A group of 88, age and gender matched, control subjects were included for this comparison study. Results The percentage of dry eye symptoms was higher in diabetic subjects (15.9%) compared with non-diabetic subjects (13.6%; p<0.001). The percentage of dry eye symptoms was also higher in diabetics with dry eye (63%) than in diabetics without dry eye (36.9%; p<0.001). Tear break up time was significantly different between diabetics and non-diabetics (p<0.001) and between diabetics with and without dry eye (p=0.046). The corneal staining was significantly different between diabetic subjects with and without dry eye (p=0.028). Conclusion Dry eye symptoms were significantly associated with diabetics. Tear break up time was significantly shorter in diabetics with dry eye compared to diabetics without dry eye. PMID:27418872

  8. Predicting the Valence of a Scene from Observers’ Eye Movements

    PubMed Central

    R.-Tavakoli, Hamed; Atyabi, Adham; Rantanen, Antti; Laukka, Seppo J.; Nefti-Meziani, Samia; Heikkilä, Janne

    2015-01-01

    Multimedia analysis benefits from understanding the emotional content of a scene in a variety of tasks such as video genre classification and content-based image retrieval. Recently, there has been an increasing interest in applying human bio-signals, particularly eye movements, to recognize the emotional gist of a scene such as its valence. In order to determine the emotional category of images using eye movements, the existing methods often learn a classifier using several features that are extracted from eye movements. Although it has been shown that eye movement is potentially useful for recognition of scene valence, the contribution of each feature is not well-studied. To address the issue, we study the contribution of features extracted from eye movements in the classification of images into pleasant, neutral, and unpleasant categories. We assess ten features and their fusion. The features are histogram of saccade orientation, histogram of saccade slope, histogram of saccade length, histogram of saccade duration, histogram of saccade velocity, histogram of fixation duration, fixation histogram, top-ten salient coordinates, and saliency map. We utilize machine learning approach to analyze the performance of features by learning a support vector machine and exploiting various feature fusion schemes. The experiments reveal that ‘saliency map’, ‘fixation histogram’, ‘histogram of fixation duration’, and ‘histogram of saccade slope’ are the most contributing features. The selected features signify the influence of fixation information and angular behavior of eye movements in the recognition of the valence of images. PMID:26407322

  9. Calibration and rectification research for fish-eye lens application

    NASA Astrophysics Data System (ADS)

    Feng, Weijia; Zhang, Baofeng; Cao, Zuoliang; Zong, Xiaoning; Röning, Juha

    2011-01-01

    The purpose of this paper aims to promote the application of fish-eye lens. Accurate parameters calibration and effective distortion rectification of an imaging device is of utmost importance in machine vision. Fish-eye lens produces a hemispherical field of view of an environment, which appears definite significant since its advantage of panoramic sight with a single compact visual scene. But fish-eye lens image has an unavoidable inherent severe distortion. The precise optical center is the precondition for other parameters calibration and distortion correction. Therefore, three different optical center calibration methods have been researched for diverse applications. Support Vector Machine (SVM) and Spherical Equidistance Projection Algorithm (SEPA) are integrated to replace traditional rectification methods. SVM is a machine learning method based on the theory of statistics, which have good capabilities of imitating, regression and classification. In this research, SVM provides a mapping table between the fish-eye image and the standard image for human eyes. Two novel training models have been designed. SEPA has been applied to promote the rectification effect of the edge of fish-eye lens image. The validity and effectiveness of our achievements are demonstrated by processing the real images.

  10. Predicting the Valence of a Scene from Observers' Eye Movements.

    PubMed

    R-Tavakoli, Hamed; Atyabi, Adham; Rantanen, Antti; Laukka, Seppo J; Nefti-Meziani, Samia; Heikkilä, Janne

    2015-01-01

    Multimedia analysis benefits from understanding the emotional content of a scene in a variety of tasks such as video genre classification and content-based image retrieval. Recently, there has been an increasing interest in applying human bio-signals, particularly eye movements, to recognize the emotional gist of a scene such as its valence. In order to determine the emotional category of images using eye movements, the existing methods often learn a classifier using several features that are extracted from eye movements. Although it has been shown that eye movement is potentially useful for recognition of scene valence, the contribution of each feature is not well-studied. To address the issue, we study the contribution of features extracted from eye movements in the classification of images into pleasant, neutral, and unpleasant categories. We assess ten features and their fusion. The features are histogram of saccade orientation, histogram of saccade slope, histogram of saccade length, histogram of saccade duration, histogram of saccade velocity, histogram of fixation duration, fixation histogram, top-ten salient coordinates, and saliency map. We utilize machine learning approach to analyze the performance of features by learning a support vector machine and exploiting various feature fusion schemes. The experiments reveal that 'saliency map', 'fixation histogram', 'histogram of fixation duration', and 'histogram of saccade slope' are the most contributing features. The selected features signify the influence of fixation information and angular behavior of eye movements in the recognition of the valence of images. PMID:26407322

  11. Predicting the Valence of a Scene from Observers' Eye Movements.

    PubMed

    R-Tavakoli, Hamed; Atyabi, Adham; Rantanen, Antti; Laukka, Seppo J; Nefti-Meziani, Samia; Heikkilä, Janne

    2015-01-01

    Multimedia analysis benefits from understanding the emotional content of a scene in a variety of tasks such as video genre classification and content-based image retrieval. Recently, there has been an increasing interest in applying human bio-signals, particularly eye movements, to recognize the emotional gist of a scene such as its valence. In order to determine the emotional category of images using eye movements, the existing methods often learn a classifier using several features that are extracted from eye movements. Although it has been shown that eye movement is potentially useful for recognition of scene valence, the contribution of each feature is not well-studied. To address the issue, we study the contribution of features extracted from eye movements in the classification of images into pleasant, neutral, and unpleasant categories. We assess ten features and their fusion. The features are histogram of saccade orientation, histogram of saccade slope, histogram of saccade length, histogram of saccade duration, histogram of saccade velocity, histogram of fixation duration, fixation histogram, top-ten salient coordinates, and saliency map. We utilize machine learning approach to analyze the performance of features by learning a support vector machine and exploiting various feature fusion schemes. The experiments reveal that 'saliency map', 'fixation histogram', 'histogram of fixation duration', and 'histogram of saccade slope' are the most contributing features. The selected features signify the influence of fixation information and angular behavior of eye movements in the recognition of the valence of images.

  12. Digital cameras with designs inspired by the arthropod eye.

    PubMed

    Song, Young Min; Xie, Yizhu; Malyarchuk, Viktor; Xiao, Jianliang; Jung, Inhwa; Choi, Ki-Joong; Liu, Zhuangjian; Park, Hyunsung; Lu, Chaofeng; Kim, Rak-Hwan; Li, Rui; Crozier, Kenneth B; Huang, Yonggang; Rogers, John A

    2013-05-01

    In arthropods, evolution has created a remarkably sophisticated class of imaging systems, with a wide-angle field of view, low aberrations, high acuity to motion and an infinite depth of field. A challenge in building digital cameras with the hemispherical, compound apposition layouts of arthropod eyes is that essential design requirements cannot be met with existing planar sensor technologies or conventional optics. Here we present materials, mechanics and integration schemes that afford scalable pathways to working, arthropod-inspired cameras with nearly full hemispherical shapes (about 160 degrees). Their surfaces are densely populated by imaging elements (artificial ommatidia), which are comparable in number (180) to those of the eyes of fire ants (Solenopsis fugax) and bark beetles (Hylastes nigrinus). The devices combine elastomeric compound optical elements with deformable arrays of thin silicon photodetectors into integrated sheets that can be elastically transformed from the planar geometries in which they are fabricated to hemispherical shapes for integration into apposition cameras. Our imaging results and quantitative ray-tracing-based simulations illustrate key features of operation. These general strategies seem to be applicable to other compound eye devices, such as those inspired by moths and lacewings (refracting superposition eyes), lobster and shrimp (reflecting superposition eyes), and houseflies (neural superposition eyes). PMID:23636401

  13. PACAP suppresses dry eye signs by stimulating tear secretion

    PubMed Central

    Nakamachi, Tomoya; Ohtaki, Hirokazu; Seki, Tamotsu; Yofu, Sachiko; Kagami, Nobuyuki; Hashimoto, Hitoshi; Shintani, Norihito; Baba, Akemichi; Mark, Laszlo; Lanekoff, Ingela; Kiss, Peter; Farkas, Jozsef; Reglodi, Dora; Shioda, Seiji

    2016-01-01

    Dry eye syndrome is caused by a reduction in the volume or quality of tears. Here, we show that pituitary adenylate cyclase-activating polypeptide (PACAP)-null mice develop dry eye-like symptoms such as corneal keratinization and tear reduction. PACAP immunoreactivity is co-localized with a neuronal marker, and PACAP receptor (PAC1-R) immunoreactivity is observed in mouse infraorbital lacrimal gland acinar cells. PACAP eye drops stimulate tear secretion and increase cAMP and phosphorylated (p)-protein kinase A levels in the infraorbital lacrimal glands that could be inhibited by pre-treatment with a PAC1-R antagonist or an adenylate cyclase inhibitor. Moreover, these eye drops suppress corneal keratinization in PACAP-null mice. PACAP eye drops increase aquaporin 5 (AQP5) levels in the membrane and pAQP5 levels in the infraorbital lacrimal glands. AQP5 siRNA treatment of the infraorbital lacrimal gland attenuates PACAP-induced tear secretion. Based on these results, PACAP might be clinically useful to treat dry eye disorder. PMID:27345595

  14. Comparative morphological analysis of compound eye miniaturization in minute hymenoptera.

    PubMed

    Makarova, Anastasia; Polilov, Alexey; Fischer, Stefan

    2015-01-01

    Due to their small size, diminutive parasitic wasps are outstanding subjects for investigating aspects of body miniaturization. Information on minute compound eyes is still scarce, and we therefore investigated eye morphology in one of the smallest known hymenopteran species Megaphragma mymaripenne (body size 0.2 mm) relative to Anaphes flavipes (body size 0.45 mm) and compared the data with available information for Trichogramma evanescens (body size 0.4 mm). The eyes of all three species are of the apposition kind, and each ommatidium possesses the typical cellular organization of ommatidia found in larger hymenopterans. Compound eye miniaturization does not therefore involve a reduction in cell numbers or elimination of cell types. Six size-related adaptations were detected in the smallest eyes investigated, namely a) a decrease in the radius of curvature of the cornea compared with larger hymenopterans; b) the lack of extensions to the basal matrix from secondary pigment cells; c) the interlocking arrangement of the retinula cell nuclei in neighboring ommatidia; d) the distal positions of retinula cell nuclei in M. mymaripenne; e) the elongated shape of retinula cell pigment granules of both studied species; and f) an increase in rhabdom diameter in M. mymaripenne compared with A. flavipes and T. evanescens. The adaptations are discussed with respect to compound eye miniaturizations as well as their functional consequences based on optical calculations.

  15. Cluster eye camera using microlenses on parabolic surface

    NASA Astrophysics Data System (ADS)

    Shen, Hui-Kai; Su, Guo-Dung J.

    2013-10-01

    There are two main types of imaging systems that exist in nature: the single aperture eye and the compound eye. Usually, cameras and most of artificial imaging systems are similar to the single aperture eye. But compound lenses can be more compact than single lenses. Our design is based on insect compound eyes, which also have a wide field of view (FOV). With the rise of micro-optical techniques, fabricating compound lenses has become easier. The simplest form of a curved microlens array is a parabolic surface. In this paper, we proposed a multi-channel imaging system, which combines the principles of the insect compound eye and the human eye. The optical system enables the reduction of track length of the imaging optics to achieve miniaturization. With the aid of optical engineering software ZEMAX, the multi-channel structure is simulated by a curved microlens array, and we use a Hypergon lens as the main lens to simulate the human eye, which can achieve the purpose of the wide FOV. With this architecture, each microlens of a microlens array transmits a segment of the overall FOV. The partial images that are separately recorded in different channels are stitched together to form the final image of the whole FOV by software processing. A 2.74 mm thin imaging system with 59 channels and 90° FOV is optimized using ZEMAX sequential ray tracing software on a 6.16 mm × 4.62 mm image plane. Finally, we will discuss the simulation results of this system and compare it with the optical cluster eye system and a mobile phone patent.

  16. Saccadic eye movement during spaceflight

    NASA Technical Reports Server (NTRS)

    Uri, John J.; Linder, Barry J.; Moore, Thomas P.; Pool, Sam L.; Thornton, William E.

    1989-01-01

    Saccadic eye movements were studied in six subjects during two Space Shuttle missions. Reaction time, peak velocity and accuracy of horizontal, visually-guided saccades were examined preflight, inflight and postflight. Conventional electro-oculography was used to record eye position, with the subjects responding to pseudo-randomly illuminated targets at 0 deg and + or - 10 deg and 20 deg visual angles. In all subjects, preflight measurements were within normal limits. Reaction time was significantly increased inflight, while peak velocity was significantly decreased. A tendency toward a greater proportion of hypometric saccades inflight was also noted. Possible explanations for these changes and possible correlations with space motion sickness are discussed.

  17. Distinct Biochemical Activities of Eyes absent During Drosophila Eye Development.

    PubMed

    Jin, Meng; Mardon, Graeme

    2016-01-01

    Eyes absent (Eya) is a highly conserved transcriptional coactivator and protein phosphatase that plays vital roles in multiple developmental processes from Drosophila to humans. Eya proteins contain a PST (Proline-Serine-Threonine)-rich transactivation domain, a threonine phosphatase motif (TPM), and a tyrosine protein phosphatase domain. Using a genomic rescue system, we find that the PST domain is essential for Eya activity and Dac expression, and the TPM is required for full Eya function. We also find that the threonine phosphatase activity plays only a minor role during Drosophila eye development and the primary function of the PST and TPM domains is transactivation that can be largely substituted by the heterologous activation domain VP16. Along with our previous results that the tyrosine phosphatase activity of Eya is dispensable for normal Eya function in eye formation, we demonstrate that a primary function of Eya during Drosophila eye development is as a transcriptional coactivator. Moreover, the PST/TPM and the threonine phosphatase activity are not required for in vitro interaction between retinal determination factors. Finally, this work is the first report of an Eya-Ey physical interaction. These findings are particularly important because they highlight the need for an in vivo approach that accurately dissects protein function. PMID:26980695

  18. The Use of Eye Tracking in Research on Video-Based Second Language (L2) Listening Assessment: A Comparison of Context Videos and Content Videos

    ERIC Educational Resources Information Center

    Suvorov, Ruslan

    2015-01-01

    Investigating how visuals affect test takers' performance on video-based L2 listening tests has been the focus of many recent studies. While most existing research has been based on test scores and self-reported verbal data, few studies have examined test takers' viewing behavior (Ockey, 2007; Wagner, 2007, 2010a). To address this gap, in the…

  19. Eye-movements and ongoing task processing.

    PubMed

    Burke, David T; Meleger, Alec; Schneider, Jeffrey C; Snyder, Jim; Dorvlo, Atsu S S; Al-Adawi, Samir

    2003-06-01

    This study tests the relation between eye-movements and thought processing. Subjects were given specific modality tasks (visual, gustatory, kinesthetic) and assessed on whether they responded with distinct eye-movements. Some subjects' eye-movements reflected ongoing thought processing. Instead of a universal pattern, as suggested by the neurolinguistic programming hypothesis, this study yielded subject-specific idiosyncratic eye-movements across all modalities. Included is a discussion of the neurolinguistic programming hypothesis regarding eye-movements and its implications for the eye-movement desensitization and reprocessing theory. PMID:12929791

  20. Improved treatment planning for COMS eye plaques

    SciTech Connect

    Astrahan, Melvin A. . E-mail: astrahan@usc.edu

    2005-03-15

    Purpose: A recent reanalysis of the Collaborative Ocular Melanoma Study (COMS) medium tumor trial concluded that incorporating factors to account for anisotropy, line source approximation, the gold plaque, and attenuation in the Silastic seed carrier into the dose calculations resulted in a significant and consistent reduction of calculated doses to structures of interest within the eye. The authors concluded that future eye plaque dosimetry should be 'performed using the most up-to-date parameters available.' The reason these factors are important is attributable to the low energy {sup 125}I radiation (approximately 28 keV) that is primarily absorbed by the photoelectric process. Photoelectric absorption is quite dependent on the atomic composition of the absorbing material. Being 40% silicon by weight, the effective atomic number of Silastic is significantly greater than that of water. Although the AAPM TG43 brachytherapy formalism inherently addresses the issues of source anisotropy and geometry, its parameter that accounts for scatter and attenuation, the radial dose function g(r), assumes that the source is immersed in infinite homogeneous water. In this work, factors are proposed for {sup 125}I that correct for attenuation in the Silastic carrier and scatter deficits resulting from the gold plaque and nearby air. The implications of using {sup 103}Pd seeds in COMS plaques are also discussed. Methods and materials: An existing TG43-based ophthalmic plaque planning system was modified to incorporate additional scatter and attenuation correction factors that better account for the path length of primary radiation in the Silastic seed carrier and the distance between the dose calculation point and the eye-air interface. Results: Compared with homogeneous water, the dose-modifying effects of the Silastic and gold are greatest near the plaque surface and immediately adjacent to the plaque, while being least near the center of the eye. The calculated dose