Sample records for f-150 operating

  1. 150 {mu}A 18F{sup -} target and beam port upgrade for the IBA 18/9 cyclotron

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stokely, M. H.; Peeples, J. L.; Poorman, M. C.

    2012-12-19

    A high power ({approx}3 kW) target platform has been developed for the IBA 18/9 cyclotron. New designs for the airlock, collimator and target subsystems have been fabricated and deployed. The primary project goal is reliable commercial production of 18F{sup -} at 150 {mu}A or greater, while secondary goals include improving serviceability and extending service intervals relative to OEM systems. Reliable operation in a production environment has been observed at beam currents up to 140 {mu}A. Challenges include ion source lifetime and localized peaking in the beam intensity distribution.

  2. A new generation of high performance engines for spacecraft propulsion

    NASA Technical Reports Server (NTRS)

    Rosenberg, Sanders D.; Schoenman, Leonard

    1991-01-01

    Experimental data validating advanced engine designs at three thrust levels (5, 15, and 100 lbF) is presented. All of the three engine designs considered employ a Moog bipropellant torque motor valve, platelet injector design, and iridium-lined rhenium combustion chamber. Attention is focused on the performance, robustness, duration, and flexibility characteristics of the engines. It is noted that the 5- and 15-lbF thrust engines can deliver a steady state specific impulse in excess of 310 lbF-sec/lbm at an area ratio of 150:1, while the 150-lbF thrust engines deliver a steady state specific impulse of 320 lbF-sec/lbm at an area ratio of 250:1. The hot-fire test results reveal specific impulse improvements of 15 to 25 sec over conventional fuel film cooled columbium chamber designs while operating at maximum chamber temperatures.

  3. Shop test of the 501F; A 150 MW combustion turbine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Entenmann, D.T.; North, W.E.; Fukue, I.

    1991-10-01

    The 501F is a 150 MW-class 60 Hz engine jointly developed by Westinghouse Electric Corporation and Mitsubishi Heavy Industries, Ltd. This paper describes the full-load shop test program for the prototype engine, as carried out in Takasago, Japan. The shop test included a full range of operating conditions, from startup through full load at the 1260{degrees} C (2300{degrees} F) design turbine inlet temperature. The engine was prepared with more than 1500 instrumentation points to monitor flow path characteristics, metal temperatures, displacements, pressures, cooling circuit characteristics, strains, sound pressure levels, and exhaust emissions. The results of this shop test indicate themore » new 501F engine design and development effort to be highly successful. The engine exceeds power and overall efficiency expectations, thus verifying the new concepts and design improvements.« less

  4. 30 CFR 75.337 - Construction and repair of seals.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 days of completion of quality control tests. (f) Welding, cutting, and soldering. Welding, cutting, and soldering with an arc or flame are prohibited within 150 feet of a seal. An operator may request a...

  5. 30 CFR 75.337 - Construction and repair of seals.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 days of completion of quality control tests. (f) Welding, cutting, and soldering. Welding, cutting, and soldering with an arc or flame are prohibited within 150 feet of a seal. An operator may request a...

  6. 30 CFR 75.337 - Construction and repair of seals.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 days of completion of quality control tests. (f) Welding, cutting, and soldering. Welding, cutting, and soldering with an arc or flame are prohibited within 150 feet of a seal. An operator may request a...

  7. 33 CFR 117.791 - Hudson River.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... least 24 hours notice is given. (d) The draw of the state highway bridge, mile 150.2 between Troy and... between Troy and Green Island, operates as follows: (1) From April 1 through December 15, the draw shall... opened. (f) The draws of the 112th Street bridge, mile 155.4 between Troy and Cohoes operate as follows...

  8. Thunderbolts and Eggshells: Composite Air Operations During Desert Storm and Implications for USAF Doctrine and Force Structure

    DTIC Science & Technology

    1994-09-01

    50 years ago as an imperative f’or a simple fighter- boamber escort team has .ince produced a highly sophisticated web of relationships between multip...encyclopedia of mission.specific u,)ject.ives that. are neither defined nor conceived at the operational level. .’lhe ATO cannot possibly cut this deep , nor...but they were nervous). [Meanwhile] F-15s are at their orbit point 150 miles deep in Iraq-waiting! We should do better than that. Responsiveness What

  9. Develop and demonstrate manufacturing processes for fabricating graphite filament reinforced polymide (Gr/PI) composite structural elements

    NASA Technical Reports Server (NTRS)

    Chase, V. A.; Harrison, E. S.

    1985-01-01

    A study was conducted to assess the merits of using graphite/polyimide, NR-150B2 resin, for structural applications on advanced space launch vehicles. The program was divided into two phases: (1) Fabrication Process Development; and (2) Demonstration Components. The first phase of the program involved the selection of a graphite fiber, quality assurance of the NR-150B2 polyimide resin, and the quality assurance of the graphite/polyimide prepreg. In the second phase of the program, a limited number of components were fabricated before the NR-150B2 resin system was removed from the market by the supplier, Du Pont. The advancement of the NR-150B2 polyimide resin binder was found to vary significantly based on previous time and temperature history during the prepregging operation. Strength retention at 316C (600F) was found to be 50% that of room temperature strength. However, the composite would retain its initial strength after 200 hours exposure at 316C (600F). Basic chemistry studies are required for determining NR-150B2 resin binder quality assurance parameters. Graphite fibers are available that can withstand high temperature cure and postcure cycles.

  10. A north-south stationkeeping ion thruster system for ATS-F.

    NASA Technical Reports Server (NTRS)

    Worlock, R.; James, E.; Ramsey, W.; Trump, G.; Gant, G.; Jan, L.; Bartlett, R.

    1972-01-01

    An ion thruster system is being developed for the ATS-F satellite to demonstrate the application of ion thruster technology to the synchronous satellite north-south stationkeeping mission. The cesium bombardment ion thruster develops one millipound thrust at 2600 seconds specific impulse and provides thrust vectoring by accelerator electrode displacement. The propellant system is sized for two years operation at 25 percent duty cycle. Power conditioning circuitry is based on transistor inverters switching at 10 kHz. Thirteen command channels allow flexibility in operation; 12 telemetry channels provide information on system performance. Input power is less than 150 watts.

  11. A Ceramic Heat Exchanger for Solar Receivers

    NASA Technical Reports Server (NTRS)

    Robertson Jr., C.; Stacy, L.

    1985-01-01

    Design intended for high-temperature service. Proposed ceramic-tube and header heat exchangers used for solar-concentrating collector operating in 25- to 150-KW power range at temperatures between 2,000 degrees and 3,000 degrees F (1,095 degrees and 1,650 degrees C).

  12. Lamb Wave Propagation in Varying Thermal Environments

    DTIC Science & Technology

    2007-03-01

    detection in structural joints (5). The Tacoma Narrows Bridge collapse, which occurred on 7 November 1940, was due to a torsional or twisting mode that...operational, the airframes can be subjected to temperature swings (-40°F to 150°F) and the corrosive effects of salts, de-icing agents, and several types...aircraft-grade aluminum plate study was used to verify wavespeed dispersion characteristics (7:428). Techniques similar to these are implemented in the

  13. Design study of shaft face seal with self-acting lift augmentation. 5: Performance in simulated gas turbine engine operation

    NASA Technical Reports Server (NTRS)

    Ludwig, L. P.; Johnson, R. L.

    1971-01-01

    The feasibility and the noncontact operation of the self-acting seal was demonstrated over a range of simulated gas turbine engine conditions from 200 to 500 ft/sec sliding speed. Sealed pressure differentials were 50 to 300 psi and sealed temperatures were 150 to 1200 F. Low leakage (about 1/10 that of conventional labyrinth seals) was exhibited in two endurance runs (200 and 338 hr) at 400 ft/sec, 200 psi and 1000 F (gas temperature). For these endurance runs, the self-acting pad wear was less than 3.8 micrometers (0.00015 in.); this low wear was attributed to the noncontact operation of the primary seal. Operating problems identified were fretting wear of the secondary seal and erosion of the primary seal by hard particles.

  14. Evaluation of cumulative dose for cone‐beam computed tomography (CBCT) scans within phantoms made from different compositions using Monte Carlo simulations

    PubMed Central

    Martin, Colin J.; Sankaralingam, Marimuthu; Oomen, Kurian; Gentle, David J.

    2015-01-01

    Measurement of cumulative dose f(0,150) with a small ionization chamber within standard polymethyl methacrylate (PMMA) CT head and body phantoms, 150 mm in length, is a possible practical method for cone‐beam computed tomography (CBCT) dosimetry. This differs from evaluating cumulative dose under scatter equilibrium conditions within an infinitely long phantom f(0,∞), which is proposed by AAPM TG‐111 for CBCT dosimetry. The aim of this study was to investigate the feasibility of using f(0,150) to estimate values for f(0,∞) in long head and body phantoms made of PMMA, polyethylene (PE), and water, using beam qualities for tube potentials of 80−140 kV. The study also investigated the possibility of using 150 mm PE phantoms for assessment of f(0,∞) within long PE phantoms, the ICRU/AAPM phantom. The influence of scan parameters, composition, and length of the phantoms was investigated. The capability of f(0,150) to assess f(0,∞) has been defined as the efficiency and assessed in terms of the ratios ϵ(f(0,150)/f(0,∞)). The efficiencies were calculated using Monte Carlo simulations for an On‐Board Imager (OBI) system mounted on a TrueBeam linear accelerator. Head and body scanning protocols with beams of width 40−500 mm were used. Efficiencies ϵ(PMMA/PMMA) and ϵ(PE/PE) as a function of beam width exhibited three separate regions. For beam widths <150 mm, ϵ(PMMA/PMMA) and ϵ(PE/PE) values were greater than 90% for the head and body phantoms. The efficiency values then fell rapidly with increasing beam width before levelling off at 74% for ϵ(PMMA/PMMA) and 69% for ϵ(PE/PE) for a 500 mm beam width. The quantities ϵ(PMMA/PE) and ϵ(PMMA/Water) varied with beam width in a different manner. Values at the centers of the phantoms for narrow beams were lower and increased to a steady state for ∼100−150 mm wide beams, before declining with increasing the beam width, whereas values at the peripheries decreased steadily with beam width. Results for ϵ(PMMA/PMMA) were virtually independent of tube potential, but there was more variation for ϵ(PMMA/PE) and ϵ(PMMA/Water). f(0,150) underestimated f(0,∞) for beam widths used for CBCT scans, thus it is necessary to use long phantoms, or apply conversion factors (Cfs) to measurements with standard PMMA CT phantoms. The efficiency values have been used to derive (Cfs) to allow evaluation of f(0,∞) from measurements of f(0,150). The (Cfs) only showed a weak dependence on scan parameters and scanner type, and so may be suitable for general application. PACS number: 87.55.K‐, 87.57.Q‐, 87.57.uq. PMID:26699590

  15. Optimizing Optics For Remotely Controlled Underwater Vehicles

    NASA Astrophysics Data System (ADS)

    Billet, A. B.

    1984-09-01

    The past decade has shown a dramatic increase in the use of unmanned tethered vehicles in worldwide marine fields. These vehicles are used for inspection, debris removal and object retrieval. With advanced robotic technology, remotely operated vehicles (ROVs) are now able to perform a variety of jobs previously accomplished only by divers. The ROVs can be used at greater depths and for riskier jobs, and safety to the diver is increased, freeing him for safer, more cost-effective tasks requiring human capabilities. Secondly, the ROV operation becomes more cost effective to use as work depth increases. At 1000 feet a diver's 10 minutes of work can cost over $100,000 including support personnel, while an ROV operational cost might be 1/20 of the diver cost per day, based on the condition that the cost for ROV operation does not change with depth, as it does for divers. In the ROV operation the television lens must be as good as the human eye, with better light gathering capability than the human eye. The RCV-150 system is an example of these advanced technology vehicles. With the requirements of manueuverability and unusual inspection, a responsive, high performance, compact vehicle was developed. The RCV-150 viewing subsystem consists of a television camera, lights, and topside monitors. The vehicle uses a low light level Newvicon television camera. The camera is equipped with a power-down iris that closes for burn protection when the power is off. The camera can pan f 50 degrees and tilt f 85 degrees on command from the surface. Four independently controlled 250 watt quartz halogen flood lamps illuminate the viewing area as required; in addition, two 250 watt spotlights are fitted. A controlled nine inch CRT monitor provides real time camera pictures for the operator. The RCV-150 vehicle component system consists of the vehicle structure, the vehicle electronics, and hydraulic system which powers the thruster assemblies and the manipulator. For this vehicle, a light weight, high response hydraulic system was developed in a very small package.

  16. Advanced Vehicle Testing Activity: High-Percentage Hydrogen/CNG Blend Ford F-150 Operating Summary - January 2003

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Karner, D.; Francfort, J.E.

    2003-01-22

    Over the past two years, Arizona Public Service, a subsidiary of Pinnacle West Capital Corporation, in cooperation with the U.S. Department of Energy's Advanced Vehicle Testing Activity, tested four gaseous fuel vehicles as part of its alternative fueled vehicle fleet. One vehicle operated initially using compressed natural gas (CNG) and later a blend of CNG and hydrogen. Of the other three vehicles, one was fueled with pure hydrogen and two were fueled with a blend of CNG and hydrogen. The three blended-fuel vehicles were originally equipped with either factory CNG engines or factory gasoline engines that were converted to runmore » CNG fuel. The vehicles were variously modified to operate on blended fuel and were tested using 15 to 50% blends of hydrogen (by volume). The pure-hydrogen-fueled vehicle was converted from gasoline fuel to operate on 100% hydrogen. All vehicles were fueled from the Arizona Public Service's Alternative Fuel Pilot Plant, which was developed to dispense gaseous fuels, including CNG, blends of CNG and hydrogen, and pure hydrogen with up to 99.9999% purity. The primary objective of the test was to evaluate the safety and reliability of operating vehicles on hydrogen and blended fuel, and the interface between the vehicles and the hydrogen fueling infrastructure. A secondary objective was to quantify vehicle emissions, cost, and performance. Over a total of 40,000 fleet test miles, no safety issues were found. Also, significant reductions in emissions were achieved by adding hydrogen to the fuel. This report presents the results of 4,695 miles of testing for one of the blended fuel vehicles, a Ford F-150 pickup truck, operating on up to 50% hydrogen-50% CNG fuel.« less

  17. Advanced Vehicle Testing Activity: Low-Percentage Hydrogen/CNG Blend, Ford F-150 -- Operating Summary

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Karner, D.; Francfort, James Edward

    2003-01-01

    Over the past two years, Arizona Public Service, a subsidiary of Pinnacle West Capital Corporation, in cooperation with the U.S. Department of Energy’s Advanced Vehicle Testing Activity, tested four gaseous fuel vehicles as part of its alternative fueled vehicle fleet. One vehicle operated initially using compressed natural gas (CNG) and later a blend of CNG and hydrogen. Of the other three vehicles, one was fueled with pure hydrogen and two were fueled with a blend of CNG and hydrogen. The three blended-fuel vehicles were originally equipped with either factory CNG engines or factory gasoline engines that were converted to runmore » CNG fuel. The vehicles were variously modified to operate on blended fuel and were tested using 15 to 50% blends of hydrogen (by volume). The pure-hydrogen-fueled vehicle was converted from gasoline fuel to operate on 100% hydrogen. All vehicles were fueled from the Arizona Public Service’s Alternative Fuel Pilot Plant, which was developed to dispense gaseous fuels, including CNG, blends of CNG and hydrogen, and pure hydrogen with up to 99.9999% purity The primary objective of the test was to evaluate the safety and reliability of operating vehicles on hydrogen and blended hydrogen fuel, and the interface between the vehicles and the hydrogen fueling infrastructure. A secondary objective was to quantify vehicle emissions, cost, and performance. Over a total of 40,000 fleet test miles, no safety issues were found. Also, significant reductions in emissions were achieved by adding hydrogen to the fuel. This report presents results of 16,942 miles of testing for one of the blended fuel vehicles, a Ford F-150 pickup truck, operating on up to 30% hydrogen/70% CNG fuel.« less

  18. Advanced Vehicle Testing Activity: Low-Percentage Hydrogen/CNG Blend Ford F-150 Operating Summary - January 2003

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Karner, D.; Francfort, J.E.

    2003-01-22

    Over the past two years, Arizona Public Service, a subsidiary of Pinnacle West Capital Corporation, in cooperation with the U.S. Department of Energy's Advanced Vehicle Testing Activity, tested four gaseous fuel vehicles as part of its alternative fueled vehicle fleet. One vehicle operated initially using compressed natural gas (CNG) and later a blend of CNG and hydrogen. Of the other three vehicles, one was fueled with pure hydrogen and two were fueled with a blend of CNG and hydrogen. The three blended-fuel vehicles were originally equipped with either factory CNG engines or factory gasoline engines that were converted to runmore » CNG fuel. The vehicles were variously modified to operate on blended fuel and were tested using 15 to 50% blends of hydrogen (by volume). The pure-hydrogen-fueled vehicle was converted from gasoline fuel to operate on 100% hydrogen. All vehicles were fueled from the Arizona Public Service's Alternative Fuel Pilot Plant, which was developed to dispense gaseous fuels, including CNG, blends of CNG and hydrogen, and pure hydrogen with up to 99.9999% purity. The primary objective of the test was to evaluate the safety and reliability of operating vehicles on hydrogen and blended hydrogen fuel, and the interface between the vehicles and the hydrogen fueling infrastructure. A secondary objective was to quantify vehicle emissions, cost, and performance. Over a total of 40,000 fleet test miles, no safety issues were found. Also, significant reductions in emissions were achieved by adding hydrogen to the fuel. This report presents results of 16,942 miles of testing for one of the blended fuel vehicles, a Ford F-150 pickup truck, operating on up to 30% hydrogen/70% CNG fuel.« less

  19. Advanced Vehicle Testing Activity: High-Percentage Hydrogen/CNG Blend, Ford F-150 -- Operating Summary

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Don Karner; Francfort, James Edward

    2003-01-01

    Over the past two years, Arizona Public Service, a subsidiary of Pinnacle West Capital Corporation, in cooperation with the U.S. Department of Energy’s Advanced Vehicle Testing Activity, tested four gaseous fuel vehicles as part of its alternative fueled vehicle fleet. One vehicle operated initially using compressed natural gas (CNG) and later a blend of CNG and hydrogen. Of the other three vehicles, one was fueled with pure hydrogen and two were fueled with a blend of CNG and hydrogen. The three blended-fuel vehicles were originally equipped with either factory CNG engines or factory gasoline engines that were converted to runmore » CNG fuel. The vehicles were variously modified to operate on blended fuel and were tested using 15 to 50% blends of hydrogen (by volume). The pure-hydrogen-fueled vehicle was converted from gasoline fuel to operate on 100% hydrogen. All vehicles were fueled from the Arizona Public Service’s Alternative Fuel Pilot Plant, which was developed to dispense gaseous fuels, including CNG, blends of CNG and hydrogen, and pure hydrogen with up to 99.9999% purity. The primary objective of the test was to evaluate the safety and reliability of operating vehicles on hydrogen and blended hydrogen fuel, and the interface between the vehicles and the hydrogen fueling infrastructure. A secondary objective was to quantify vehicle emissions, cost, and performance. Over a total of 40,000 fleet test miles, no safety issues were found. Also, significant reductions in emissions were achieved by adding hydrogen to the fuel. This report presents the results of 4,695 miles of testing for one of the blended fuel vehicles, a Ford F-150 pickup truck, operating on up to 50% hydrogen–50% CNG fuel.« less

  20. Development of helicopter engine seals

    NASA Technical Reports Server (NTRS)

    Lynwander, P.

    1973-01-01

    An experimental evaluation of main shaft seals for helicopter gas turbine engines was conducted with shaft speeds to 213 m/s(700 ft/sec), air pressures to 148 N/sq cm (215 psia), and air temperatures to 645 K (675 F). Gas leakage test results indicate that conventional seals will not be satisfactory for high-pressure sealing because of excessive leakage. The self-acting face seal, however, had significantly lower leakage and operated with insignificant wear during a 150-hour endurance test at sliding speeds to 145 m/s (475 ft/sec), air pressures to 124 N/sq cm (180 psia), and air temperatures to 408 K (275 F). Wear measurements indicate that noncontact operation was achieved at shaft speeds of 43,000 rpm. Evaluation of the self-acting circumferential seal was inconclusive because of seal dimensional variations.

  1. High-Temperature Piezoelectric Ceramic Developed

    NASA Technical Reports Server (NTRS)

    Sayir, Ali; Farmer, Serene C.; Dynys, Frederick W.

    2005-01-01

    Active combustion control of spatial and temporal variations in the local fuel-to-air ratio is of considerable interest for suppressing combustion instabilities in lean gas turbine combustors and, thereby, achieving lower NOx levels. The actuator for fuel modulation in gas turbine combustors must meet several requirements: (1) bandwidth capability of 1000 Hz, (2) operating temperature compatible with the fuel temperature, which is in the vicinity of 400 F, (3) stroke of approximately 4 mils (100 m), and (4) force of 300 lb-force. Piezoelectric actuators offer the fastest response time (microsecond time constants) and can generate forces in excess of 2000 lb-force. The state-of-the-art piezoceramic material in industry today is Pb(Zr,Ti)O3, called PZT. This class of piezoelectric ceramic is currently used in diesel fuel injectors and in the development of high-response fuel modulation valves. PZT materials are generally limited to operating temperatures of 250 F, which is 150 F lower than the desired operating temperature for gas turbine combustor fuel-modulation injection valves. Thus, there is a clear need to increase the operating temperature range of piezoceramic devices for active combustion control in gas turbine engines.

  2. 76 FR 53308 - Airworthiness Directives; Cessna Aircraft Company Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    ... Airworthiness Directives; Cessna Aircraft Company Airplanes AGENCY: Federal Aviation Administration (FAA), DOT... (AD) for certain Cessna Aircraft Company (Cessna) Models 150F, 150G, 150H, 150J, 150K, 150L, 150M... Friday, except Federal holidays. For service information identified in this AD, contact Cessna Aircraft...

  3. High temperature oxidation-resistant thruster research

    NASA Technical Reports Server (NTRS)

    Wooten, John R.; Lansaw, P. Tina

    1990-01-01

    A program was conducted for NASA-LeRC by Aerojet Propulsion Division to establish the technology base for a new class of long-life, high-performance, radiation-cooled bipropellant thrusters capable of operation at temperatures over 2200 C (4000 F). The results of a systematic, multi-year program are described starting with the preliminary screening tests which lead to the final material selection. Life greater than 15 hours was demonstrated on a workhorse iridium-lined rhenium chamber at chamber temperatures between 2000 and 2300 C (3700 and 4200 F). The chamber was fabricated by the Chemical Vapor Deposition at Ultramet. The program culminated in the design, fabrication, and hot-fire test of an NTO/MMH 22-N (5-lbF) class thruster containing a thin wall iridium-lined rhenium thrust chamber with a 150:1 area ratio nozzle. A specific impulse of 310 seconds was measured and front-end thermal management was achieved for steady state and several pulsing duty cycles. The resulting design represents a 20 second specific impulse improvement over conventional designs in which the use of disilicide coated columbium chambers limit operation to 1300 C (2400 F).

  4. Development of MBE grown Pb-salt semiconductor lasers for the 8.0 to 15.0 micrometer spectral region

    NASA Technical Reports Server (NTRS)

    Miller, M. D.

    1981-01-01

    Diodes lasers are fabricated using multiple source molecular beam expitaxial growth of (PbSn)Te on BaF2 substrates. Methods for crystal growth, crystal transfer, and device fabrication by photolithographic techniques were developed. The lasers operate in the spectra range from 10 microns to 14 microns and at temperatures from 12K to 60K continuous wave and to 95 K pulsed.

  5. Low-cost, single-mode diode-pumped Cr:Colquiriite lasers.

    PubMed

    Demirbas, Umit; Li, Duo; Birge, Jonathan R; Sennaroglu, Alphan; Petrich, Gale S; Kolodziejski, Leslie A; Kaertner, Franz X; Fujimoto, James G

    2009-08-03

    We present three Cr3+:Colquiriite lasers as low-cost alternatives to Ti:Sapphire laser technology. Single-mode laser diodes, which cost only $150 each, were used as pump sources. In cw operation, with approximately 520 mW of absorbed pump power, up to 257, 269 and 266 mW of output power and slope efficiencies of 53%, 62% and 54% were demonstrated for Cr:LiSAF, Cr:LiSGaF and Cr:LiCAF, respectively. Record cw tuning ranges from 782 to 1042 nm for Cr:LiSAF, 777 to 977 nm for Cr:LiSGaF, and 754 to 871 nm for Cr:LiCAF were demonstrated. In cw mode-locking experiments using semiconductor saturable absorber mirrors at 800 and 850 nm, Cr:Colquiriite lasers produced approximately 50-100 fs pulses with approximately 1-2.5 nJ pulse energies at approximately 100 MHz repetition rate. Electrical-to-optical conversion efficiencies of 8% in mode-locked operation and 12% in cw operation were achieved.

  6. Department of the Navy Justification of Estimates for Fiscal Years 1988 and 1989 Submitted to Congress January 1987. Operation & Maintenance, Navy. Book 1. Budget Activity 1. Strategic Forces Budget Activity 2. General Purpose Forces Budget Activity 4. Airlift and Sealift.

    DTIC Science & Technology

    1987-01-01

    166 174 170 167 Config Change Rqsts 45 54 53 52 Config Audits 20 26 26 25 Manual Change Rqsts 516 500 489 477 Work Years 91 90 90 90 7) Noise Reduction... manual methods. 771 ’ 1 1-50 3442f/7 Activity Group: Space Systems Operations (cont’d) AMOUNT C. Other Program Growth in FY 1989 (878) 1) Space...P+WS htp ~ h Na vy lr,(j Ma? itf’ to a nri rt. r 1’r f 1, Pri y t, i lu, iwe, a t ion, t a t H % ;, i rndi t 04 l I r k 4, PMfi , . j(I l j ,’Ř

  7. 33 CFR 150.506 - When must the operator service inflatable lifesaving appliances and marine evacuation systems?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... inflatable lifesaving appliances and marine evacuation systems? 150.506 Section 150.506 Navigation and...: OPERATIONS Emergency and Specialty Equipment Inflatable Lifesaving Appliances § 150.506 When must the operator service inflatable lifesaving appliances and marine evacuation systems? (a) The operator must...

  8. 33 CFR 150.510 - How must tested emergency equipment be operated?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false How must tested emergency equipment be operated? 150.510 Section 150.510 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF... Operational Tests and Inspections (general) § 150.510 How must tested emergency equipment be operated? The...

  9. 33 CFR 150.510 - How must tested emergency equipment be operated?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false How must tested emergency equipment be operated? 150.510 Section 150.510 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF... Operational Tests and Inspections (general) § 150.510 How must tested emergency equipment be operated? The...

  10. FBXL5 interacts with p150 {sup Glued} and regulates its ubiquitination

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang Ning; Liu Jing; Ding Xia

    2007-07-20

    The microtubule motor cytoplasmic dynein and its activator dynactin drive vesicular transport and mitotic spindle organization. p150 {sup Glued} is the dynactin subunit responsible for binding to dynein and microtubules. The F-box proteins constitute one of the four subunits of ubiquitin protein ligase complex called SCFs (SKP1-cullin-F-box), which governs phosphorylation-dependent ubiquitination and subsequent proteolysis. Our recent study showed that the proteolysis of mitotic kinesin CENP-E is mediated by SCF via a direct Skp1 link [D. Liu, N. Zhang, J. Du, X. Cai, M. Zhu, C. Jin, Z. Dou, C. Feng, Y. Yang, L. Liu, K. Takeyasu, W. Xie, X. Yao,more » Interaction of Skp1 with CENP-E at the midbody is essential for cytokinesis, Biochem. Biophys. Res. Commun. 345 (2006) 394-402]. Here we show that F-box protein FBXL5 interacts with p150 {sup Glued} and orchestrates its turnover via ubiquitination. FBXL5 binds to p150 {sup Glued} in vitro and in vivo. FBXL5 and p150 {sup Glued} co-localize primarily in the cytoplasm with peri-nuclear enrichment in HeLa cells. Overexpression of FBXL5 promotes poly-ubiquitination of p150 {sup Glued} and protein turnover of p150 {sup Glued} . Our findings provide a potential mechanism by which p150 {sup Glued} protein function is regulated by SCFs.« less

  11. Tagnite and Keronite Assessment on Magnesium & Aluminum

    DTIC Science & Technology

    2014-11-19

    8” nozzle , 10” standoff, 80 degree angle, & 25 psi nozzle pressure  Acceptable coating removal rate determined to be between 0.3-0.5 ft2/min...Propulsion Directorate CEE-BEE 300 FLM Degreaser, 25 minutes, 150F, ultrasonic tank CEE-BEE 300 FLM Degreaser, 25 minutes, 150F, ultrasonic tank DI

  12. 33 CFR 150.507 - How must the operator service inflatable lifesaving appliances?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... inflatable lifesaving appliances? 150.507 Section 150.507 Navigation and Navigable Waters COAST GUARD... Specialty Equipment Inflatable Lifesaving Appliances § 150.507 How must the operator service inflatable lifesaving appliances? (a) The operator must service each inflatable liferaft according to 46 CFR subpart 160...

  13. 33 CFR 150.20 - How many copies of the operations manual must be given to the Coast Guard?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false How many copies of the operations manual must be given to the Coast Guard? 150.20 Section 150.20 Navigation and Navigable Waters COAST... § 150.20 How many copies of the operations manual must be given to the Coast Guard? The draft operations...

  14. Functional analysis of unfermented and fermented citrus peels and physical properties of citrus peel-added doughs for bread making.

    PubMed

    Shyu, Yung-Shin; Lu, Tzu-Chi; Lin, Chuan-Chuan

    2014-12-01

    Several studies have indicated citrus peels (CP) contain specific methoxy flavones, e.g. nobiletin and tangeretin, which have been shown to prevent numerous diseases. However, research reports regarding their application as food additive in healthy baked products is scarce. In our study, both unfermented (UF) and fermented (F) citrus peels were processed under different dry hot-air temperatures to make four citrus peel powders , UF-100 °C,UF-150 °C, F-100 °C, F-150 °C, respectively. The analysis of the basic components and nutraceuticals as well as antioxidant activity were conducted. Various percentages of CP were added to dough and toast bread for physical property and sensory evaluations. The results indicated the contents of crude proteins (3.3-4.3 mg/g) and fibers (10.9-14.9 %) among the four samples were similar. The UF extracts showed better antioxidant activities than F extracts. HPLC analysis indicated the contents of hesperidine, nobiletin and tangeretin in CP extracts were UF-150 °C > UF-100 °C. Farinograph analysis indicated a linear relation between CP powder content and the parameters of the physical properties of dough. A high percentage of fibrous CP powder in dough increases the water adsorption capacity of the dough, resulting in a decrease in its stability The sensory evaluation results indicated a greater acceptability of UF-added toast bread relative to the F-added one. Among these, according to the statistical anaylsis, the UF-150 °C 4 % and UF-100 °C 6 % groups were the best and F-150 °C 2 % group was the poorest in overall acceptability.

  15. Reactivity of some halogenated alkanes of 13X molecular sieve

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fevrier, D.; Vernet, J.L.; Mignon, P.

    1977-12-01

    The decomposition and transhalogenation products of trichlorofluoromethane (F 11), dichlorodifluoromethane (F-12), dichlorofluoromethane (F-21), chlorodifluoromethane (F-22), trichlorotrifluoroethane (F-113), and bromotrifluoromethane (F-13B1) in air on 13X molecular sieve at 150/sup o/ and 320/sup o/C were analyzed. All compounds decomposed to some extent except F-13B1 and F-113 at 150/sup o/C. The decomposition product was carbon dioxide except from F-21 and F-22, which decomposed more readily than the other Freons because of their hydrogen atoms and which yielded carbon monoxide. The sieves were not regenerated by sweeping with water in nitrogen, although adsorbed halogens were displaced and formed strong acids. Halogenated hydracids formed alongmore » with carbon dioxide by reaction with constitutional water of the sieves are probably responsible for the destruction of the sieve. Diagram, graphs, tables, and 17 references.« less

  16. 3D Boundary Element Analysis for Composite Joints with discrete Damage. Part 1.

    DTIC Science & Technology

    1996-11-15

    WHS/DIOR, Oct 94 Fracture Analysis Consultants, Inc. 121 Eastern Heights Dr. Ithaca, New York 14850 (607) 257-4970 SBIR Topic AF96 -150 3D Boundary...41 1 F33615-96-C-5070 SBIR Topic AF96 -150: Phase I Final Report Sunmmry Report WL/MLBM solicited Phase I SBIR proposals to develop a capability...materials; no precomputations are required. 2 F33615-96-C-5070 SBIR Topic AF96 -150: Phase I Final Report Task 6. We have developed a fully 3D Galerkin BEM

  17. Design and Synthesis of 3D Potassium-Ion Pre-Intercalated Graphene for Supercapacitors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chang, Liang; Stacchiola, Dario J.; Hu, Yun Hang

    Here in this paper, a novel material—3D potassium-ion preintercalated graphene—was designed and synthesized via one step using a new reaction between K and CO. Furthermore, this material exhibited excellent performance as electrodes for aqueous symmetrical supercapacitors. When the electrode was scaled up from 3.0 to 8.0 mg/cm 2, negligible capacitance degradation was observed, leading to a very high areal capacitance of 1.50 F/cm 2 at 1 A/g. Furthermore, even if a large operating temperature of -15 or 55 °C was employed, its excellent electrochemical performance remained with specific capacitances of 208 F/g at 55 °C, 184 F/g at 25 °C,more » and 98 F/g at -15 °C. This could be attributed to 3D structure and K+ preintercalation of the material, which provides rich active sites for electric double-layer formation, lower ion transport resistance, and shorter diffusion distance.« less

  18. Design and Synthesis of 3D Potassium-Ion Pre-Intercalated Graphene for Supercapacitors

    DOE PAGES

    Chang, Liang; Stacchiola, Dario J.; Hu, Yun Hang

    2018-02-22

    Here in this paper, a novel material—3D potassium-ion preintercalated graphene—was designed and synthesized via one step using a new reaction between K and CO. Furthermore, this material exhibited excellent performance as electrodes for aqueous symmetrical supercapacitors. When the electrode was scaled up from 3.0 to 8.0 mg/cm 2, negligible capacitance degradation was observed, leading to a very high areal capacitance of 1.50 F/cm 2 at 1 A/g. Furthermore, even if a large operating temperature of -15 or 55 °C was employed, its excellent electrochemical performance remained with specific capacitances of 208 F/g at 55 °C, 184 F/g at 25 °C,more » and 98 F/g at -15 °C. This could be attributed to 3D structure and K+ preintercalation of the material, which provides rich active sites for electric double-layer formation, lower ion transport resistance, and shorter diffusion distance.« less

  19. U.S. Department of Energy FreedomCAR & Vehicle Technologies Program Advanced Vehicle Testing Activity, Hydrogen/CNG Blended Fuels Performance Testing in a Ford F-150

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    James E. Francfort

    2003-11-01

    Federal regulation requires energy companies and government entities to utilize alternative fuels in their vehicle fleets. To meet this need, several automobile manufacturers are producing compressed natural gas (CNG)-fueled vehicles. In addition, several converters are modifying gasoline-fueled vehicles to operate on both gasoline and CNG (Bifuel). Because of the availability of CNG vehicles, many energy company and government fleets have adopted CNG as their principle alternative fuel for transportation. Meanwhile, recent research has shown that blending hydrogen with CNG (HCNG) can reduce emissions from CNG vehicles. However, blending hydrogen with CNG (and performing no other vehicle modifications) reduces engine powermore » output, due to the lower volumetric energy density of hydrogen in relation to CNG. Arizona Public Service (APS) and the U.S. Department of Energy’s Advanced Vehicle Testing Activity (DOE AVTA) identified the need to determine the magnitude of these effects and their impact on the viability of using HCNG in existing CNG vehicles. To quantify the effects of using various blended fuels, a work plan was designed to test the acceleration, range, and exhaust emissions of a Ford F-150 pickup truck operating on 100% CNG and blends of 15 and 30% HCNG. This report presents the results of this testing conducted during May and June 2003 by Electric Transportation Applications (Task 4.10, DOE AVTA Cooperative Agreement DEFC36- 00ID-13859).« less

  20. Comparison of High-Speed Operating Characteristics of Size 215 Cylindrical-Roller Bearings as Determined in Turbojet Engine and in Laboratory Test Rig

    NASA Technical Reports Server (NTRS)

    Macks, E Fred; Nemeth, Zolton N

    1951-01-01

    A comparison of the operating characteristics of 75-millimeter-bore (size 215) cylindrical-roller one-piece inner-race-riding cage-type bearings was made using a laboratory test rig and a turbojet engine. Cooling correlation parameters were determined by means of dimensional analysis, and the generalized results for both the inner- and outer-race bearing operating temperatures are compared for the laboratory test rig and the turbojet engine. Inner- and outer-race cooling-correlation curves were obtained for the turbojet-engine turbine-roller bearing with the same inner- and outer-race correlation parameters and exponents as those determined for the laboratory test-rig bearing. The inner- and outer-race turbine roller-bearing temperatures may be predicted from a single curve, regardless of variations in speed, load, oil flow, oil inlet temperature, oil inlet viscosity, oil-jet diameter or any combination of these parameters. The turbojet-engine turbine-roller-bearing inner-race temperatures were 30 to 60 F greater than the outer-race-maximum temperatures, the exact values depending on the operating condition and oil viscosity; these results are in contrast to the laboratory test-rig results where the inner-race temperatures were less than the outer-race-maximum temperatures. The turbojet-engine turbine-roller bearing, maximum outer-race circumferential temperature variation was approximately 30 F for each of the oils used. The effect of oil viscosity on inner- and outer-race turbojet-engine turbine-roller-bearing temperatures was found to be significant. With the lower viscosity oil (6x10(exp -7) reyns (4.9 centistokes) at 100 F; viscosity index, 83), the inner-race temperature was approximately 30 to 35 F less than with the higher viscosity oil (53x10(exp -7) reyns (42.8 centistokes) at 100 F; viscosity index, 150); whereas the outer-race-maximum temperatures were 12 to 28 F lower with the lower viscosity oil over the DN range investigated.

  1. 30 CFR 35.6 - Application procedures and requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) Pour point, °F.; freezing point, °F.; color; neutralization number or pH; viscosity at 100 °F., 150 °F., 175 °F. (Saybolt or Furol); viscosity index; specific gravity. (3) A statement of the water or other...

  2. 30 CFR 35.6 - Application procedures and requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) Pour point, °F.; freezing point, °F.; color; neutralization number or pH; viscosity at 100 °F., 150 °F., 175 °F. (Saybolt or Furol); viscosity index; specific gravity. (3) A statement of the water or other...

  3. 30 CFR 35.6 - Application procedures and requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) Pour point, °F.; freezing point, °F.; color; neutralization number or pH; viscosity at 100 °F., 150 °F., 175 °F. (Saybolt or Furol); viscosity index; specific gravity. (3) A statement of the water or other...

  4. High-pressure cryogenic seals for pressure vessels

    NASA Technical Reports Server (NTRS)

    Buggele, A. E.

    1977-01-01

    This investigation of the problems associated with reliably containing gaseous helium pressurized to 1530 bars (22 500 psi) between 4.2 K and 150 K led to the following conclusions: (1) common seal designs used in existing elevated-temperature pressure vessels are unsuitable for high-pressure cryogenic operation, (2) extrusion seal-ring materials such as Teflon, tin, and lead are not good seal materials for cryogenic high-pressure operation; and (3) several high-pressure cryogenic seal systems suitable for large-pressure vessel applications were developed; two seals required prepressurization, and one seal functioned repeatedly without any prepressurization. These designs used indium seal rings, brass or 304 stainless-steel anvil rings, and two O-rings of silicone rubber or Kel-F.

  5. The quality of intensive care unit nurse handover related to end of life: a descriptive comparative international study.

    PubMed

    Ganz, Freda DeKeyser; Endacott, Ruth; Chaboyer, Wendy; Benbinishty, Julie; Ben Nun, Maureen; Ryan, Helen; Schoter, Amanda; Boulanger, Carole; Chamberlain, Wendy; Spooner, Amy

    2015-01-01

    Quality ICU end-of-life-care has been found to be related to good communication. Handover is one form of communication that can be problematic due to lost or omitted information. A first step in improving care is to measure and describe it. The objective of this study was to describe the quality of ICU nurse handover related to end-of-life care and to compare the practices of different ICUs in three different countries. This was a descriptive comparative study. The study was conducted in seven ICUs in three countries: Australia (1 unit), Israel (3 units) and the UK (3 units). A convenience sample of 157 handovers was studied. Handover quality was rated based on the ICU End-of-Life Handover tool, developed by the authors. The highest levels of handover quality were in the areas of goals of care and pain management while lowest levels were for legal issues (proxy and advanced directives) related to end of life. Significant differences were found between countries and units in the total handover score (country: F(2,154)=25.97, p=<.001; unit: F(6,150)=58.24, p=<.001), for the end of life subscale (country: F(2, 154)=28.23, p<.001; unit: F(6,150)=25.25, p=<.001), the family communication subscale (country: F(2,154)=15.04, p=<.001; unit: F(6,150)=27.38, p=<.001), the family needs subscale (F(2,154)=22.33, p=<.001; unit: F(6,150)=42.45, p=<.001) but only for units on the process subscale (F(6,150)=8.98, p=<.001. The total handover score was higher if the oncoming RN did not know the patient (F(1,155)=6.51, p=<.05), if the patient was expected to die during the shift (F(1,155)=89.67, p=<.01) and if the family were present (F(1,155)=25.81, p=<.01). Practices of end-of-life-handover communication vary greatly between units. However, room for improvement exists in all areas in all of the units studied. The total score was higher when quality of care might be deemed at greater risk (if the nurses did not know the patient or the patient was expected to die), indicating that nurses were exercising some form of discretionary decision making around handover communication; thus validating the measurement tool. Copyright © 2014. Published by Elsevier Ltd.

  6. Low-voltage differentially-signaled modulators.

    PubMed

    Zortman, William A; Lentine, Anthony L; Trotter, Douglas C; Watts, Michael R

    2011-12-19

    For exascale computing applications, viable optical solutions will need to operate using low voltage signaling and with low power consumption. In this work, the first differentially signaled silicon resonator is demonstrated which can provide a 5dB extinction ratio using 3fJ/bit and 500mV signal amplitude at 10Gbps. Modulation with asymmetric voltage amplitudes as low as 150mV with 3dB extinction are demonstrated at 10Gbps as well. Differentially signaled resonators simplify and expand the design space for modulator implementation and require no special drivers.

  7. Transformer room fire tests

    NASA Astrophysics Data System (ADS)

    Fustich, C. D.

    1980-03-01

    A series of transformer room fire tests are reported to demonstate the shock hazard present when automatic sprinklers operate over energized electrical equipment. Fire protection was provided by standard 0.5 inch pendent automatic sprinklers temperature rated at 135 F and installed to give approximately 150 sq ft per head coverage. A 480 v dry transformer was used in the room to provide a three phase, four wire distribution system. It is shown that the induced currents in the test room during the various tests are relatively small and pose no appreciable personnel shock hazard.

  8. Tezacaftor/Ivacaftor in Subjects with Cystic Fibrosis and F508del/F508del-CFTR or F508del/G551D-CFTR.

    PubMed

    Donaldson, Scott H; Pilewski, Joseph M; Griese, Matthias; Cooke, Jon; Viswanathan, Lakshmi; Tullis, Elizabeth; Davies, Jane C; Lekstrom-Himes, Julie A; Wang, Linda T

    2018-01-15

    Tezacaftor (formerly VX-661) is an investigational small molecule that improves processing and trafficking of the cystic fibrosis transmembrane conductance regulator (CFTR) in vitro, and improves CFTR function alone and in combination with ivacaftor. To evaluate the safety and efficacy of tezacaftor monotherapy and of tezacaftor/ivacaftor combination therapy in subjects with cystic fibrosis homozygous for F508del or compound heterozygous for F508del and G551D. This was a randomized, placebo-controlled, double-blind, multicenter, phase 2 study (NCT01531673). Subjects homozygous for F508del received tezacaftor (10 to 150 mg) every day alone or in combination with ivacaftor (150 mg every 12 h) in a dose escalation phase, as well as in a dosage regimen testing phase. Subjects compound heterozygous for F508del and G551D, taking physician-prescribed ivacaftor, received tezacaftor (100 mg every day). Primary endpoints were safety through Day 56 and change in sweat chloride from baseline through Day 28. Secondary endpoints included change in percent predicted FEV 1 (ppFEV 1 ) from baseline through Day 28 and pharmacokinetics. The incidence of adverse events was similar across treatment arms. Tezacaftor (100 mg every day)/ivacaftor (150 mg every 12 h) resulted in a 6.04 mmol/L decrease in sweat chloride and 3.75 percentage point increase in ppFEV 1 in subjects homozygous for F508del, and a 7.02 mmol/L decrease in sweat chloride and 4.60 percentage point increase in ppFEV 1 in subjects compound heterozygous for F508del and G551D from baseline through Day 28 (P < 0.05 for all). These results support continued clinical development of tezacaftor (100 mg every day) in combination with ivacaftor (150 mg every 12 h) in subjects with cystic fibrosis. Clinical trial registered with www.clinicaltrials.gov (NCT01531673).

  9. 33 CFR 150.616 - What are the requirements for lockout?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... lockout? 150.616 Section 150.616 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Workplace Safety and Health Lockout/tagout § 150.616 What are the requirements for lockout? The deepwater port operator must ensure that, if...

  10. Ceramic tube seals cut heat loss, achieve six month payback

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1985-11-01

    The methane reformer at the Celanese Chemical Company's Bishop, TX plant operates at approximately 1900/sup 0/F. The reformer has 32 tubes (9'' diameter) that pass through the firebox. Openings around the tubes measure 11'' in diameter to accommodate horizontal and vertical thermal expansion and movement as well as to facilitate tube removal. The gaps around the tubes permitted cool air to be drawn into the firebox (caused by slight negative pressure) and also allowed radiant heat to escape causing the reformer to operate at a lower than desired level of thermal efficiency. Celanese contracted to retrofit the old rigid firebrickmore » roof in the methane reformer with a 10'' thick ceramic fiber module lining. The gaps around the tubes were sealed by using a special tube seal made from Nextel woven ceramic fiber fabric, a 1984 CHEMICAL PROCESSING Vaaler Award winner (Mid-November 1984, p.52). The Nextel fabric used in this application is a heat resistant textile that has a continuous use temperature of 2200/sup 0/F - well above the 1900/sup 0/F operating temperature of the reformer. The tube seals have been working exactly as intended, verified by observation through inspection ports. Temperatures in the penthouse area above the roof dropped from 240/sup 0/F to 150/sup 0/F. The reduction in heat losses has been attributed to the elimination of the gaps around each tube by the seals and to the improved K-factor of the ceramic module lining. The tube seals have paid for themselves within six months of installation. At that time, the seal boots were inspected and showed no signs of wear. With these results, the improved efficiency of the methane reformer promises to yield additional economic benefits.« less

  11. 33 CFR 150.555 - How must cranes be maintained?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false How must cranes be maintained? 150.555 Section 150.555 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... Operations § 150.555 How must cranes be maintained? Cranes must be operated, maintained, and tested in...

  12. 33 CFR 150.555 - How must cranes be maintained?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false How must cranes be maintained? 150.555 Section 150.555 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... Operations § 150.555 How must cranes be maintained? Cranes must be operated, maintained, and tested in...

  13. 33 CFR 150.620 - What are the requirements for protecting personnel from machinery?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... protecting personnel from machinery? 150.620 Section 150.620 Navigation and Navigable Waters COAST GUARD... Health Machine Guards § 150.620 What are the requirements for protecting personnel from machinery? The deepwater port operator must ensure that all personnel are protected from the risks created by operating...

  14. 33 CFR 150.620 - What are the requirements for protecting personnel from machinery?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... protecting personnel from machinery? 150.620 Section 150.620 Navigation and Navigable Waters COAST GUARD... Health Machine Guards § 150.620 What are the requirements for protecting personnel from machinery? The deepwater port operator must ensure that all personnel are protected from the risks created by operating...

  15. 33 CFR 150.620 - What are the requirements for protecting personnel from machinery?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... protecting personnel from machinery? 150.620 Section 150.620 Navigation and Navigable Waters COAST GUARD... Health Machine Guards § 150.620 What are the requirements for protecting personnel from machinery? The deepwater port operator must ensure that all personnel are protected from the risks created by operating...

  16. 33 CFR 150.620 - What are the requirements for protecting personnel from machinery?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... protecting personnel from machinery? 150.620 Section 150.620 Navigation and Navigable Waters COAST GUARD... Health Machine Guards § 150.620 What are the requirements for protecting personnel from machinery? The deepwater port operator must ensure that all personnel are protected from the risks created by operating...

  17. Enhancement of Intermittent Androgen Ablation Therapy by Finasteride Administration in Animal Models

    DTIC Science & Technology

    2005-02-01

    40 E 250° U0 200- 0 150- 50- 01 Treament group (tumor volume in cm3 at time of randomization) Figure 2: a) Mean percent change in LNCaP tumor volume...40- S30- . 20- 10 CAA F T T+F c 350- 300- OM P 250- 2! ." Q. 0 200- 0 150- ~.100 ** ’ 50 Treament group (tumor volume in cm 3 at time of randomization

  18. Dependence of the colored frequency noise in spin torque oscillators on current and magnetic field

    NASA Astrophysics Data System (ADS)

    Eklund, Anders; Bonetti, Stefano; Sani, Sohrab R.; Majid Mohseni, S.; Persson, Johan; Chung, Sunjae; Amir Hossein Banuazizi, S.; Iacocca, Ezio; Östling, Mikael; Åkerman, Johan; Gunnar Malm, B.

    2014-03-01

    The nano-scale spin torque oscillator (STO) is a compelling device for on-chip, highly tunable microwave frequency signal generation. Currently, one of the most important challenges for the STO is to increase its longer-time frequency stability by decreasing the 1/f frequency noise, but its high level makes even its measurement impossible using the phase noise mode of spectrum analyzers. Here, we present a custom made time-domain measurement system with 150 MHz measurement bandwidth making possible the investigation of the variation of the 1/f as well as the white frequency noise in a STO over a large set of operating points covering 18-25 GHz. The 1/f level is found to be highly dependent on the oscillation amplitude-frequency non-linearity and the vicinity of unexcited oscillation modes. These findings elucidate the need for a quantitative theoretical treatment of the low-frequency, colored frequency noise in STOs. Based on the results, we suggest that the 1/f frequency noise possibly can be decreased by improving the microstructural quality of the metallic thin films.

  19. 33 CFR 150.608 - Who is responsible for ensuring that the personnel use or wear protective equipment and are...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... DEEPWATER PORTS: OPERATIONS Workplace Safety and Health Personal Protective Equipment § 150.608 Who is...) Each deepwater port operator must ensure that all personnel wear personal protective equipment when... that the personnel use or wear protective equipment and are trained in its use? 150.608 Section 150.608...

  20. 33 CFR 150.608 - Who is responsible for ensuring that the personnel use or wear protective equipment and are...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... DEEPWATER PORTS: OPERATIONS Workplace Safety and Health Personal Protective Equipment § 150.608 Who is...) Each deepwater port operator must ensure that all personnel wear personal protective equipment when... that the personnel use or wear protective equipment and are trained in its use? 150.608 Section 150.608...

  1. 33 CFR 150.505 - When must the operator service and examine lifeboat and rescue boat release gear?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... and examine lifeboat and rescue boat release gear? 150.505 Section 150.505 Navigation and Navigable... and examine lifeboat and rescue boat release gear? (a) The operator must service lifeboat and rescue boat release gear at intervals recommended in the manufacturer's instructions under § 150.502(a), or...

  2. 33 CFR 150.505 - When must the operator service and examine lifeboat and rescue boat release gear?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... and examine lifeboat and rescue boat release gear? 150.505 Section 150.505 Navigation and Navigable... and examine lifeboat and rescue boat release gear? (a) The operator must service lifeboat and rescue boat release gear at intervals recommended in the manufacturer's instructions under § 150.502(a), or...

  3. 33 CFR 150.505 - When must the operator service and examine lifeboat and rescue boat release gear?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... and examine lifeboat and rescue boat release gear? 150.505 Section 150.505 Navigation and Navigable... and examine lifeboat and rescue boat release gear? (a) The operator must service lifeboat and rescue boat release gear at intervals recommended in the manufacturer's instructions under § 150.502(a), or...

  4. 33 CFR 150.505 - When must the operator service and examine lifeboat and rescue boat release gear?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... and examine lifeboat and rescue boat release gear? 150.505 Section 150.505 Navigation and Navigable... and examine lifeboat and rescue boat release gear? (a) The operator must service lifeboat and rescue boat release gear at intervals recommended in the manufacturer's instructions under § 150.502(a), or...

  5. 33 CFR 150.505 - When must the operator service and examine lifeboat and rescue boat release gear?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... and examine lifeboat and rescue boat release gear? 150.505 Section 150.505 Navigation and Navigable... and examine lifeboat and rescue boat release gear? (a) The operator must service lifeboat and rescue boat release gear at intervals recommended in the manufacturer's instructions under § 150.502(a), or...

  6. Lithium cell tests at Langley Research Center. [for the long duration exposure facility

    NASA Technical Reports Server (NTRS)

    Bene, J.

    1977-01-01

    The long duration exposure facility mission places temperature requirements of from -30 F to +150 F on the batteries to be used. A hermetically sealed lithium sulfur dioxide cell was tested to predict what the temperature of the battery would be over a given spectrum of temperatures of operation. Near the end of cell discharge, as the voltage started collapsing, a very high heat output rise due to chemical reaction took place. However, if the cells were thermally insulated, they vented, ignited, and burned if an attempt was made to discharge them all the way. The cells do not go into reversal. It was determined that the root of the problem was probably the chemical reaction between the lithium and the acetonitrite solvent. A redesigned cell is discussed as well as some alternates.

  7. The Influence of Ship Motions on Operations of SH-2F Helicopters from DF-1052-Class Ships: Sea Trial with USS Bowen (DE-1079)

    DTIC Science & Technology

    1975-07-01

    correlated to wind speed and that a knowledge of wind speeds alone is not adequate for pre- dieting ship motions during which aircraft events are intended...3.10 1.36 Le2.o 233 1 0m.7 9.30 2.6.7 CIS .90 if1 3.90 -1.05 .08 .02.5 .04p -:a19 9.99 PCO too a.0 233 16.7 150 26.7 02.5 I. IS .00 3.60 -50S .08

  8. Low-noise magnetoencephalography system cooled by a continuously operating reliquefier

    NASA Astrophysics Data System (ADS)

    Lee, Y. H.; Kwon, H.; Yu, K. K.; Kim, J. M.; Lee, S. K.; Kim, M.-Y.; Kim, K.

    2017-08-01

    We fabricated a low-noise magnetoencephalography (MEG) system based on a continuously operating reliquefier for cooling of low-temperature superconducting quantum interference device gradiometers. In order to reduce the vibration transmission, the gradiometers are mounted in the vacuum space of the helmet dewar with direct thermal contact with the liquid helium helmet. The reliquefier uses a 1.4 W pulse tube cryocooler with a remote motor, and a horizontal transfer tube with a downslope angle of 1°. The white noise of the system is 3.5 fTrms/√Hz (at 100 Hz). The vibration-induced peak at 1.4 Hz is 18 fTrms/√Hz averaged over the whole helmet array of 150 channels, which is the lowest among the reported values using reliquefier cooling and comparable to the noise peak cooled by conventional direct liquid helium cooling with axial gradiometers of the same baseline. The spontaneous brain activity signal showed nearly identical signal quality with the reliquefier turned on and off, and the reliquefier-based MEG system noise is well below the brain noise level.

  9. Metabolic Responses to Swimming Exercise in the Infected Rat.

    DTIC Science & Technology

    1981-06-29

    Dunning rats (F-344, F, MA Bioproducts) weighing 150-200 g. ’hey were maintained on a commercial diet (Wayne-Blox, Allied Mills, Inc.) until the...Disease, edited by Kinney and Lense. Columbus, Ohio: Ross Laboratories, 19S0, p. 144-150. 4. BERGSTROM, J., L. HERMANSEN, E. HULITMAN, AND B. SALTIN. Diet ...hepatic ketogenic capacity in fed rats by anti-insulin serum and glucagon. J. Clii:. Invest. 55:1202-1209, 1975. 21. MOSES, 1L. E. Determination of oxygen

  10. Development of multi-layer crystal detector and related front end electronics

    NASA Astrophysics Data System (ADS)

    Cardarelli, R.; Di Ciaccio, A.; Paolozzi, L.

    2014-05-01

    A crystal (diamond) particle detector has been developed and tested, whose constitute elements are a multi-layer polycrystalline diamond and a pick-up system capable of collecting in parallel the charge produced in the layers. The charge is read with a charge-to-voltage amplifier (5-6 mV/fC) realized with bipolar junction transistors in order to minimize the effect of the detector capacitance. The tests performed with cosmic rays and at the beam test facility of Frascati with 500 MeV electrons in single electron mode operation have shown that a detector with 4-5 layers of 250 μm thickness each and 9 mm2 active area exhibits an upper limit of 150 ps time resolution for minimum ionizing particles at an operating voltage of about 350 V.

  11. Optical design of f-theta lens for dual wavelength selective laser melting

    NASA Astrophysics Data System (ADS)

    Feng, Lianhua; Cao, Hongzhong; Zhang, Ning; Xu, Xiping; Duan, Xuanming

    2016-10-01

    F-theta lens is an important unit for selective laser melting (SLM) manufacture. The dual wavelength f-theta lens has not been used in SLM manufacture. Here, we present the design of the f-theta lens which satisfies SLM manufacture with coaxial 532 nm and 1030 nm 1080 nm laser beams. It is composed of three pieces of spherical lenses. The focal spots for 532 nm laser and 1030 nm 1080 nm laser are smaller than 35 μm and 70 μm, respectively. The results meet the demands of high precision SLM. The chromatic aberration could cause separation between two laser focal spots in the scanning plane, so chromatic aberration correction is very important to our design. The lateral color of the designed f-theta lens is less than 11 μm within the scan area of 150 mm x 150 mm, which meet the application requirements of dual wavelength selective laser melting.

  12. 33 CFR 150.508 - What are the maintenance and repair requirements for inflatable rescue boats?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... repair requirements for inflatable rescue boats? 150.508 Section 150.508 Navigation and Navigable Waters... repair requirements for inflatable rescue boats? The operator must perform the maintenance and repair of inflatable rescue boats according to the manufacturer's instructions. Operational Tests and Inspections...

  13. 33 CFR 150.508 - What are the maintenance and repair requirements for inflatable rescue boats?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... repair requirements for inflatable rescue boats? 150.508 Section 150.508 Navigation and Navigable Waters... repair requirements for inflatable rescue boats? The operator must perform the maintenance and repair of inflatable rescue boats according to the manufacturer's instructions. Operational Tests and Inspections...

  14. 33 CFR 150.508 - What are the maintenance and repair requirements for inflatable rescue boats?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... repair requirements for inflatable rescue boats? 150.508 Section 150.508 Navigation and Navigable Waters... repair requirements for inflatable rescue boats? The operator must perform the maintenance and repair of inflatable rescue boats according to the manufacturer's instructions. Operational Tests and Inspections...

  15. 33 CFR 150.508 - What are the maintenance and repair requirements for inflatable rescue boats?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... repair requirements for inflatable rescue boats? 150.508 Section 150.508 Navigation and Navigable Waters... repair requirements for inflatable rescue boats? The operator must perform the maintenance and repair of inflatable rescue boats according to the manufacturer's instructions. Operational Tests and Inspections...

  16. 33 CFR 150.508 - What are the maintenance and repair requirements for inflatable rescue boats?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... repair requirements for inflatable rescue boats? 150.508 Section 150.508 Navigation and Navigable Waters... repair requirements for inflatable rescue boats? The operator must perform the maintenance and repair of inflatable rescue boats according to the manufacturer's instructions. Operational Tests and Inspections...

  17. All-solid-state single longitudinal mode MOPA laser system

    NASA Astrophysics Data System (ADS)

    Zhang, Xiang; Gu, Haidong; Hu, Wenhua; Ren, Shilong

    2018-03-01

    Side diode pumped electro-optical Q Switching Nd: YAG is demonstrated as master oscillator. F-P etalon and twisted-mode cavity combined configuration is introduced to select longitudinal modes. The seed light experiences a round trip through the two flash pump amplifiers, in this device, the 4f image transmission system and SBS phase conjugate mirror is adopted in order to improved beam quality, by compensating the heat depolarization effect and eliminate wave-front distortion. In the condition of 1 or 5 repetitions of the wavelength at 1064nm, it produces the pulse energy of 300mJ, pulse width of 12ns, and energy instability (RMS) below 3% in single longitudinal mode operation. With a type two-phase matched KTP crystal, 532nm green light is yielded, at 1 Hz repetition rate, the pulse energy of green light is more than 150mJ.

  18. 33 CFR 150.504 - When must the operator service and examine lifeboat and rescue boat launching appliances?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... and examine lifeboat and rescue boat launching appliances? 150.504 Section 150.504 Navigation and... and examine lifeboat and rescue boat launching appliances? (a) The operator must service launching appliances for lifeboats and rescue boats at intervals recommended in the manufacturer's instructions under...

  19. 33 CFR 150.504 - When must the operator service and examine lifeboat and rescue boat launching appliances?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... and examine lifeboat and rescue boat launching appliances? 150.504 Section 150.504 Navigation and... and examine lifeboat and rescue boat launching appliances? (a) The operator must service launching appliances for lifeboats and rescue boats at intervals recommended in the manufacturer's instructions under...

  20. 33 CFR 150.504 - When must the operator service and examine lifeboat and rescue boat launching appliances?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... and examine lifeboat and rescue boat launching appliances? 150.504 Section 150.504 Navigation and... and examine lifeboat and rescue boat launching appliances? (a) The operator must service launching appliances for lifeboats and rescue boats at intervals recommended in the manufacturer's instructions under...

  1. 33 CFR 150.504 - When must the operator service and examine lifeboat and rescue boat launching appliances?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... and examine lifeboat and rescue boat launching appliances? 150.504 Section 150.504 Navigation and... and examine lifeboat and rescue boat launching appliances? (a) The operator must service launching appliances for lifeboats and rescue boats at intervals recommended in the manufacturer's instructions under...

  2. 33 CFR 150.504 - When must the operator service and examine lifeboat and rescue boat launching appliances?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... and examine lifeboat and rescue boat launching appliances? 150.504 Section 150.504 Navigation and... and examine lifeboat and rescue boat launching appliances? (a) The operator must service launching appliances for lifeboats and rescue boats at intervals recommended in the manufacturer's instructions under...

  3. Integrated, Flexible, High-efficiency Solar Cells: Epitaxial Lift-Off GaAs Solar Cells and Enabling Substrate Reuse

    DTIC Science & Technology

    2012-08-01

    substrate cells. 3   GaAs CIGS CdTe α-SI Organic Trip. jun. Metam. C-Si Trip. Jun. Ge sub InP Power/Weight  Tradeoff...40   -  AR  coa<ng  ( ZnS /MgF2)150nm...AR  coa<ng  ( ZnS /MgF2)150nm                                      $5   -  HF

  4. Miniature Sensor Probe for O2, CO2, and H2O Monitoring in Portable Life Support Systems

    NASA Technical Reports Server (NTRS)

    Delgado, Jesus; Chambers, Antja

    2013-01-01

    A miniature sensor probe, composed of four sensors which monitor the partial pressure of O2, CO2, H2O, and temperature, designed to operate in the portable life support system (PLSS), has been demonstrated. The probe provides an important advantage over existing technology in that it is able to operate reliably while wet. These luminescence-based fiber optic sensors consist of an indicator chemistry immobilized in a polymeric film, whose emission lifetime undergoes a strong change upon a reversible interaction with the target gas. Each sensor includes chemistry specifically sensitive to one target parameter. All four sensors are based on indicator chemistries that include luminescent dyes from the same chemical family, and therefore exhibit similar photochemical properties, which allow performing measurements of all the sensors by a single, compact, low-power optoelectronic unit remotely connected to the sensors by an electromagnetic interference-proof optical fiber cable. For space systems, using these miniature sensor elements with remote optoelectronics provides unmatched design flexibility for measurements in highly constrained volume systems such as the PLSS. A 10 mm diameter and 15 mm length prototype multiparameter probe was designed, fabricated, tested, and demonstrated over a wide operational range of gas concentration, humidity, and temperature relevant to operation in the PLSS. The sensors were evaluated for measurement range, precision, accuracy, and response time in temperatures ranging from 50 aF-150 aF and relative humidity from dry to 100% RH. Operation of the sensors in water condensation conditions was demonstrated wherein the sensors not only tolerated liquid water but actually operated while wet.

  5. Effect of two inner-ring oil-flow distribution schemes on the operating characteristics of a 35 millimeter bore ball bearing to 2.5 million DN

    NASA Technical Reports Server (NTRS)

    Schuller, F. T.; Pinel, S. I.; Signer, H. R.

    1985-01-01

    Parametric tests were conducted with a 35-mm-bore, split-inner-ring ball bearing with a double-inner-land-guided cage. Provisions were made for through-the-inner-ring lubrication. Test condictions were either a thrust load of 667 N (150 lb) or a combined load of 667 N (150 lb) thrust and 222 N (50 lb) radial, shaft speeds from 32000 to 72000 rpm, and an oil-inlet temperature of 394 K (250 deg F). Outer ring cooling was used in some tests. Tests were run with either 50 or 75 percent of the total oil flow distributed to the inner-ring raceway. Successful operation was experienced with both 50% and 75% flow patterns to 2.5 million DN. Cooling the outer ring had little effect on inner-ring temperature; however, the outer-ring temperature decreased as much as 7% at 2.5 million DN. Maximum recorded power loss was 3.1 kW (4.2 hp), and maximum cage slip was 8.7 percent. Both occurred at a shaft speed of 72000 rpm, a lubricant flow rate of 1900 cu/min (0.50 gal/min), a combined load, and no outer-ring cooling.

  6. A Virtual Instrument for Micro Doppler Analysis of Signals in SAR/ISAR: Parameters Estimation and Focusing Moving Targets

    DTIC Science & Technology

    2014-12-01

    itu de (d) Figure 14: 34 DRDC-RDDC-2014- frequency ti m e (a) frequency in de x (b) 0 50 100 150 200 250...frequency tim e (a) frequency in de x (b) 0 50 100 150 200 250 am pl itu de (d) 0 50 100 150 200 250 am pl itu de (c) tim e frequency (e) in de x...frequency (f) 0 50 100 150 200 250 frequency am pl itu de (h) 0 50 100 150 200 250 frequency am pl itu de (g) Figure 9: DRDC-RDDC-2014- 23 24

  7. High-density SNP Scan of Production and Product Quality Traits in Beef Cattle

    USDA-ARS?s Scientific Manuscript database

    Genotypes from the BovineSNP50 BeadChip (50K) were obtained on animals derived from 150 AI sires from seven breeds (22 sires per breed; Angus, Charolais, Gelbvieh, Hereford, Limousin, Red Angus, and Simmental) as either progeny (F1; 590 steers) or grandprogeny (F1 x F1 = F1**2; 1,306 steers and 707 ...

  8. 33 CFR 150.511 - What are the operational testing requirements for lifeboat and rescue boat release gear?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... requirements for lifeboat and rescue boat release gear? 150.511 Section 150.511 Navigation and Navigable Waters... operational testing requirements for lifeboat and rescue boat release gear? (a) Lifeboat and rescue boat... rescue boat when loaded with its full complement of persons and equipment. (b) The test must be conducted...

  9. 33 CFR 150.511 - What are the operational testing requirements for lifeboat and rescue boat release gear?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... requirements for lifeboat and rescue boat release gear? 150.511 Section 150.511 Navigation and Navigable Waters... operational testing requirements for lifeboat and rescue boat release gear? (a) Lifeboat and rescue boat... rescue boat when loaded with its full complement of persons and equipment. (b) The test must be conducted...

  10. 33 CFR 150.511 - What are the operational testing requirements for lifeboat and rescue boat release gear?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... requirements for lifeboat and rescue boat release gear? 150.511 Section 150.511 Navigation and Navigable Waters... operational testing requirements for lifeboat and rescue boat release gear? (a) Lifeboat and rescue boat... rescue boat when loaded with its full complement of persons and equipment. (b) The test must be conducted...

  11. 33 CFR 150.511 - What are the operational testing requirements for lifeboat and rescue boat release gear?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... requirements for lifeboat and rescue boat release gear? 150.511 Section 150.511 Navigation and Navigable Waters... operational testing requirements for lifeboat and rescue boat release gear? (a) Lifeboat and rescue boat... rescue boat when loaded with its full complement of persons and equipment. (b) The test must be conducted...

  12. 33 CFR 150.511 - What are the operational testing requirements for lifeboat and rescue boat release gear?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... requirements for lifeboat and rescue boat release gear? 150.511 Section 150.511 Navigation and Navigable Waters... operational testing requirements for lifeboat and rescue boat release gear? (a) Lifeboat and rescue boat... rescue boat when loaded with its full complement of persons and equipment. (b) The test must be conducted...

  13. Combustion performance and heat transfer characterization of LOX/hydrocarbon type propellants, volume 1

    NASA Technical Reports Server (NTRS)

    Michel, R. W.

    1983-01-01

    A program to evaluate liquid oxygen and various hydrocarbon fuel as low cost alternative propellants suitable for future space transportation system applications is discussed. The emphasis of the program is directed toward low earth orbit maneuvering engine and reaction control engine systems. The feasibility of regeneratively cooling an orbit maneuvering thruster was analytically determined over a range of operating conditions from 100 to 1000 psia chamber pressure and 1000 to 10,000-1bF thrust, and specific design points were analyzed in detail for propane, methane, RP-1, ammonia, and ethanol; similar design point studies were performed for a filmcooled reaction control thruster. Heat transfer characteristics of propate were experimentally evaluated in heated tube tests. Forced convection heat transfer coefficients were determined over the range of fluid conditions encompassed by 450 to 1800 psia, -250 to +250 F, and 50 to 150 ft/sec, with wall temperatures from ambient to 1200 F. Seventy-seven hot firing tests were conducted with LOX/propane and LOC/ethanol, for a total duration of nearly 1400 seconds, using both heat sink and water-cooled calorimetric chambers.

  14. The Detector System for the Stratospheric Kinetic Inductance Polarimeter ( Skip)

    NASA Astrophysics Data System (ADS)

    Johnson, B. R.; Ade, P. A. R.; Araujo, D.; Bradford, K. J.; Chapman, D.; Day, P. K.; Didier, J.; Doyle, S.; Eriksen, H. K.; Flanigan, D.; Groppi, C.; Hillbrand, S.; Jones, G.; Limon, M.; Mauskopf, P.; McCarrick, H.; Miller, A.; Mroczkowski, T.; Reichborn-Kjennerud, B.; Smiley, B.; Sobrin, J.; Wehus, I. K.; Zmuidzinas, J.

    2014-09-01

    The stratospheric kinetic inductance polarimeter is a proposed balloon-borne experiment designed to study the cosmic microwave background, the cosmic infrared background and Galactic dust emission by observing 1,133 deg of sky in the Northern Hemisphere with launches from Kiruna, Sweden. The instrument contains 2,317 single-polarization, horn-coupled, aluminum lumped-element kinetic inductance detectors ( Lekids). The Lekids will be maintained at 100 mK with an adiabatic demagnetization refrigerator. The polarimeter operates in two configurations, one sensitive to a spectral band centered on 150 GHz and the other sensitive to 260 and 350 GHz bands. The detector readout system is based on the ROACH-1 board, and the detectors will be biased below 300 MHz. The detector array is fed by an F/2.4 crossed-Dragone telescope with a 500 mm aperture yielding a 15 arcmin FWHM beam at 150 GHz. To minimize detector loading and maximize sensitivity, the entire optical system will be cooled to 1 K. Linearly polarized sky signals will be modulated with a metal-mesh half-wave plate that is mounted at the telescope aperture and rotated by a superconducting magnetic bearing. The observation program consists of at least two, 5-day flights beginning with the 150 GHz observations.

  15. The Stratospheric Kinetic Inductance Polarimeter (SKIP)

    NASA Astrophysics Data System (ADS)

    Flanigan, Daniel; Ade, P.; Araujo, D.; Bradford, K. J.; Chapman, D.; Che, G.; Day, P.; Didier, J.; Doyle, S.; Eriksen, H.; Groppi, C. E.; Hillbrand, S. N.; Johnson, B.; Jones, G.; Limon, M.; Mauskopf, P.; McCarrick, H.; Miller, A. D.; Mroczkowski, T.; Reichborn-Kjennerud, B.; Smiley, B.; Sobrin, J.; Wehus, I. K.; Zmuidzinas, J.

    2014-01-01

    We discuss the Stratospheric Kinetic Inductance Polarimeter (SKIP). SKIP is a proposed balloon-borne experiment designed to study the cosmic microwave background, the cosmic infrared background, and Galactic dust emission by observing 1100 square degrees of sky in the Northern Hemisphere with launches from Kiruna, Sweden. The instrument contains 2317 single-polarization, horn-coupled, aluminum lumped-element kinetic inductance detectors (LEKIDs), which will be maintained at 100 mK by an adiabatic demagnetization refrigerator. The polarimeter will operate in two configurations, one sensitive to a spectral band centered on 150 GHz and the other sensitive to 260 and 350 GHz bands. The detector readout system is based on the ROACH-1 board, and the detectors will be biased below 300 MHz. The detector array is fed by an F/2.4 crossed-Dragone telescope with a 500 mm aperture yielding a 15 arcminute full-width half-maximum beam at 150 GHz. To minimize detector loading and maximize sensitivity, the entire optical system will be cooled to 1 K. Linearly polarized sky signals will be modulated with a metal-mesh half-wave plate that is mounted at the telescope aperture and is rotated on a superconducting magnetic bearing. The observation program consists of two or more five-day flights, and 150 GHz observations are planned to begin in 2017.

  16. 75 FR 47881 - Noise Exposure Map Notice, T.F.Green Airport, Warwick, RI

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-09

    ... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Noise Exposure Map Notice, T.F.Green... Aviation Administration (FAA) announces its determination that the noise exposure maps for T.F.Green... Aviation Safety and Noise Abatement Act of 1979 (Pub. L. 96-193) and 14 CFR part 150, are in compliance...

  17. Abnormal spermatogenesis following sodium fluoride exposure is associated with the downregulation of CREM and ACT in the mouse testis.

    PubMed

    Wang, Chong; Chen, Yan; Manthari, Ram Kumar; Wang, Jundong

    2018-04-01

    cAMP response element modulator (CREM) is involved in regulating gene expression in normal spermatogenesis. The transcriptional activity of CREM is partly regulated by activator of CREM in the testis (ACT). To investigate the effects of different concentrations of sodium fluoride (NaF) on the gene and protein expression of CREM and ACT in the mouse testis, sexually mature male Kunming mice were exposed to 50, 100, or 150 mg/L NaF in their drinking water for 90 days. NaF reduced the sperm count and viability and increased the percentage of malformed sperm in a dose-dependent manner. The mRNA expression of CREM and ACT was markedly downregulated in the NaF-treated groups. Furthermore, immunohistochemistry revealed that CREM and ACT proteins were decreased significantly in the 50, 100, and 150 mg/L NaF-treated groups compared to the control group. These findings indicate that the decreased gene and protein expression of CREM and ACT in the testis is associated with an impairment of reproductive functions by NaF.

  18. 45 CFR 150.343 - Notice of proposed penalty.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ....343 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES REQUIREMENTS RELATING TO HEALTH CARE ACCESS... Non-Federal Governmental Plans-Civil Money Penalties § 150.343 Notice of proposed penalty. If CMS... entity's right to a hearing. (f) A statement that failure to request a hearing within 30 days permits the...

  19. 45 CFR 150.343 - Notice of proposed penalty.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ....343 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES REQUIREMENTS RELATING TO HEALTH CARE ACCESS... Non-Federal Governmental Plans-Civil Money Penalties § 150.343 Notice of proposed penalty. If CMS... entity's right to a hearing. (f) A statement that failure to request a hearing within 30 days permits the...

  20. 45 CFR 146.150 - Guaranteed availability of coverage for employers in the small group market.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... SERVICES REQUIREMENTS RELATING TO HEALTH CARE ACCESS REQUIREMENTS FOR THE GROUP HEALTH INSURANCE MARKET Provisions Applicable to Only Health Insurance Issuers § 146.150 Guaranteed availability of coverage for... paragraphs (c) through (f) of this section, each health insurance issuer that offers health insurance...

  1. Fatigue Sensor Evaluation Program Laboratory Test Report.

    DTIC Science & Technology

    1975-10-01

    Temp 2.2 +150 to -50°F, Alum Specimen 2.5 ±150 to -50°F, Steel Specimen 2.5 Rerun of Test #1 2.1 Load levels indicated are in units of...1050 +150 6 Hll ±450 +800 +1250 +350 1 H12 ±500 -400 +100 -900 1 H13 ±500 0 +500 -500 2 H14 ±500 +200 +700 -300 1 H15 ±500 +600 +1100 +100 6 H16...IDENT. HA HB HC HD HE HF HG HH HI HJ LO AD BL OC K NU MB ER S PE R TA BL E 9 H10 H10 H24~’ H14 ’ H29 H17 H17 ’ H13 H18 H17 H24 H22 H12 HI H3

  2. Survival of Anisakis simplex in microwave-processed arrowtooth flounder (Atheresthes stomias).

    PubMed

    Adams, A M; Miller, K S; Wekell, M M; Dong, F M

    1999-04-01

    The purpose of this study was to define the relationship between survival and temperature of nematodes of the species Anisakis simplex in microwave-processed arrowtooth flounder (Atheresthes stomias). Ten fillets (each 126 to 467 g, 0.5 to 1.75 cm thick), with an average of five larvae of Anisakis simplex per fillet, were processed to target temperatures on high (100%) power using a commercial 700-W microwave oven. Fillets were neither covered nor rotated and had a temperature probe inserted to two-thirds depth into the thickest portion. After the fillet was digested using a 1% pepsin solution, the viability of nematodes was determined by viewing them under a dissecting microscope. Survival rates were 31% at 140 degrees F (60 degrees C), 11% at 150 degrees F (65 degrees C), 2% at 160 degrees F (71 degrees C), 3% at 165 degrees F (74 degrees C), and 0% at 170 degrees F (77 degrees C). Microwave processing of standardized fillet "sandwiches," 14 cm long, 4.5 cm wide, and approximately 1.75 cm high, each of which was preinoculated with 10 live nematodes, resulted in no survival at either 160 degrees F or 170 degrees F. Using ultraviolet light to detect both viable and nonviable nematodes in fillet sandwiches as an alternative method to pepsin digestion resulted in survival rates of 1% at 140 degrees F (60 degrees C), 3% at 145 degrees F (63 degrees C), and 0% at 150 degrees F (65 degrees C). Smaller fillet sandwiches, which most likely had fewer cold spots during microwave processing, required 150 degrees F (65 degrees C), whereas larger whole fillets required 170 degrees F (77 degrees C) to kill larvae of Anisakis simplex. The parasites were most likely inactivated by a thermal mechanism of microwave treatment. Damage to the nematodes was often evident from ruptured cuticles that were no longer resistant to digestive enzymes. The high hydrostatic pressure and low chloride content of the pseudocoelomic fluid probably contributed greatly to the damage incurred by the larvae.

  3. True Asymptotic Plasma-Sheath Matching with an Asymptotically Correct Collisional Presheath

    DTIC Science & Technology

    1989-06-30

    and shifted in velocity according to a generalization sructure amkse acca un redected l.ow, trapped ions, and of the Bohm criterion [51. (61. urice...2,10.2) (IPARAM(I),I-1,5) CLOSE (2) WRITE (*, 109) STOP c 101 FORMAT ( F8 .1/F8.1/F6.3/F6.3/F6.3/F6.3/F7.2/F5.2/F6. 1) 102 FORMAT (I1/I1/I3/I3/I3) 103...150 FRA(X’********************I &JX’****TEC START 151 FORMAT(F8.1/ F8 .i/F6.3/F6.3

  4. High operating temperature interband cascade focal plane arrays

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tian, Z.-B.; Godoy, S. E.; Kim, H. S.

    2014-08-04

    In this paper, we report the initial demonstration of mid-infrared interband cascade (IC) photodetector focal plane arrays with multiple-stage/junction design. The merits of IC photodetectors include low noise and efficient photocarrier extraction, even for zero-bias operation. By adopting enhanced electron barrier design and a total absorber thickness of 0.7 μm, the 5-stage IC detectors show very low dark current (1.10 × 10{sup −7} A/cm{sup 2} at −5 mV and 150 K). Even with un-optimized fabrication and standard commercial (mis-matched) read-out circuit technology, infrared images are obtained by the 320 × 256 IC focal plane array up to 180 K with f/2.3 optics. The minimum noise equivalent temperature differencemore » of 28 mK is obtained at 120 K. These initial results indicate great potential of IC photodetectors, particularly for high operating temperature applications.« less

  5. 40 CFR 68.150 - Submission.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 15 2011-07-01 2011-07-01 false Submission. 68.150 Section 68.150 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CHEMICAL ACCIDENT PREVENTION PROVISIONS Risk Management Plan § 68.150 Submission. (a) The owner or operator shall...

  6. 40 CFR 68.150 - Submission.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 15 2010-07-01 2010-07-01 false Submission. 68.150 Section 68.150 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CHEMICAL ACCIDENT PREVENTION PROVISIONS Risk Management Plan § 68.150 Submission. (a) The owner or operator shall...

  7. Assessment and Control of the Transoceanic Fallout Threat

    DTIC Science & Technology

    1974-08-01

    15 150 Peach 300 30 90 900 Orange 50 5.0 15 150 27 where m is the muscle mass in grams, f. is the fraction of the nuclide that is assimulated (in...Yearly composites are analyzed for eight radionuclides by a gamma scan, and radiochemical analyses are performed to obtain radium and strontium-90

  8. 42 CFR 483.150 - Statutory basis; Deemed meeting or waiver of requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... CARE FACILITIES Requirements That Must Be Met by States and State Agencies: Nurse Aide Training and Competency Evaluation, and Paid Feeding Assistants § 483.150 Statutory basis; Deemed meeting or waiver of... 1919(f)(2) of the Act, which establish standards for training nurse-aides and for evaluating their...

  9. 42 CFR 483.150 - Statutory basis; Deemed meeting or waiver of requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... CARE FACILITIES Requirements That Must Be Met by States and State Agencies: Nurse Aide Training and Competency Evaluation, and Paid Feeding Assistants § 483.150 Statutory basis; Deemed meeting or waiver of... 1919(f)(2) of the Act, which establish standards for training nurse-aides and for evaluating their...

  10. 42 CFR 483.150 - Statutory basis; Deemed meeting or waiver of requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... CARE FACILITIES Requirements That Must Be Met by States and State Agencies: Nurse Aide Training and Competency Evaluation, and Paid Feeding Assistants § 483.150 Statutory basis; Deemed meeting or waiver of... 1919(f)(2) of the Act, which establish standards for training nurse-aides and for evaluating their...

  11. 42 CFR 483.150 - Statutory basis; Deemed meeting or waiver of requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... CARE FACILITIES Requirements That Must Be Met by States and State Agencies: Nurse Aide Training and Competency Evaluation, and Paid Feeding Assistants § 483.150 Statutory basis; Deemed meeting or waiver of... 1919(f)(2) of the Act, which establish standards for training nurse-aides and for evaluating their...

  12. Guided training relative to direct skill training for individuals with cognitive impairments after stroke: a pilot randomized trial

    PubMed Central

    Skidmore, Elizabeth R.; Butters, Meryl; Whyte, Ellen; Grattan, Emily; Shen, Jennifer; Terhorst, Lauren

    2016-01-01

    Objective To examine the effects of direct skill training and guided training for promoting independence after stroke. Design Single-blind randomized pilot study. Setting Inpatient rehabilitation facility. Participants Forty-three participants in inpatient rehabilitation with acute stroke and cognitive impairments. Interventions Participants were randomized to receive direct skill training (n=22, 10 sessions as adjunct to usual inpatient rehabilitation) or guided training (n=21, same dose). Main Outcome Measure The Functional Independence Measure assessed independence at baseline, rehabilitation discharge, and months 3, 6, and 12. Results Linear mixed models (random intercept, other effects fixed) revealed a significant intervention by time interaction (F4,150=5.11, p<0.001), a significant main effect of time (F4,150=49.25, p<0.001), and a significant effect of stroke severity (F1,150=34.46, p<.001). There was no main effect of intervention (F1,150=0.07, p=0.79). Change in Functional Independence Measures scores was greater for the DIRECT group at rehabilitation discharge (effect size of between group differences, d=0.28) and greater for the GUIDE group at months 3 (d=0.16), 6 (d=0.39), and 12 (d=0.53). The difference between groups in mean 12 month change scores was 10.57 points. Conclusions Guided training, provided in addition to usual care, offered a small advantage in the recovery of independence, relative to direct skill training. Future studies examining guided training in combination with other potentially potent intervention elements may further advise best practices in rehabilitation for individuals with cognitive impairments after acute stroke. PMID:27794487

  13. An experimental study of the solubility and speciation of tantalum in fluoride-bearing aqueous solutions at elevated temperature

    DOE PAGES

    Timofeev, Alexander; Migdisov, Art. A.; Williams-Jones, A. E.

    2016-10-27

    Here, the solubility of Ta 2O 5 (solid) and the speciation of tantalum in HF-bearing aqueous solutions have been determined at temperatures of 100-250 °C and vapour-saturated water pressure. Tantalum is transported as the species Ta(OH) 5 0 at low HF concentration and pH ~1-3. At higher HF concentration, tantalum mobility is controlled by the species TaF 3(OH) 3- and TaF 5; the presence of TaF 5 0 is only evident at ≤150 °C. Equilibrium constants range from -17.4 ± 0.45 to -16.4 ± 0.12 for the formation of Ta(OH) 5 from crystalline Ta 2O 5 and from -8.24 ±more » 0.64 to -8.55 ± 0.68 for the formation of TaF 3(OH) 3- at 100 and 250 °C, respectively. For TaF 5 0, they were determined to be 0.13 at 100 °C and -0.35 at 150 °C.« less

  14. 7 CFR 4279.150 - Feasibility studies.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 15 2011-01-01 2011-01-01 false Feasibility studies. 4279.150 Section 4279.150... § 4279.150 Feasibility studies. A feasibility study by a qualified independent consultant may be required... affect the borrower's operations. An acceptable feasibility study should include, but not be limited to...

  15. 7 CFR 4279.150 - Feasibility studies.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 15 2010-01-01 2010-01-01 false Feasibility studies. 4279.150 Section 4279.150... § 4279.150 Feasibility studies. A feasibility study by a qualified independent consultant may be required... affect the borrower's operations. An acceptable feasibility study should include, but not be limited to...

  16. 5 CFR 1207.150 - Program accessibility: Existing facilities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... facilities. 1207.150 Section 1207.150 Administrative Personnel MERIT SYSTEMS PROTECTION BOARD ORGANIZATION... CONDUCTED BY THE MERIT SYSTEMS PROTECTION BOARD § 1207.150 Program accessibility: Existing facilities. (a) General. The agency shall operate each program or activity so that the program or activity, when viewed in...

  17. 33 CFR 150.612 - What footwear is required?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false What footwear is required? 150.612 Section 150.612 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Workplace Safety and Health Feet § 150.612 What...

  18. Anodic composite deposition of RuO2/reduced graphene oxide/carbon nanotube for advanced supercapacitors

    NASA Astrophysics Data System (ADS)

    Hu, Chi-Chang; Wang, Chia-Wei; Chang, Kuo-Hsin; Chen, Ming-Guan

    2015-07-01

    Anodic composite deposition is demonstrated to be a unique method for fabricating a ternary ruthenium dioxide/reduced graphene oxide/carbon nanotube (RuO2 · xH2O/rGO/CNT, denoted as RGC) nanocomposite onto Ti as an advanced electrode material for supercapacitors. The rGO/CNT composite in RGCs acts as a conductive backbone to facilitate the electron transport between current collector and RuO2 · xH2O nanoparticles (NPs), revealed by the high total specific capacitance (CS,T = 808 F g-1) of RGC without annealing. The contact resistance among RuO2 · xH2O NPs is improved by low-temperature annealing at 150 °C (RGC-150), which renders slight sintering and enhances the specific capacitance of RuO2 · xH2O to achieve 1200 F g-1. The desirable nanocomposite microstructure of RGC-150 builds up the smooth pathways of both protons and electrons to access the active oxy-ruthenium species. This nanocomposite exhibits an extremely high CS,T of 973 F g-1 at 25 mV s-1 (much higher than 435 F g-1 of an annealed RuO2 · xH2O deposit) and good capacitance retention (60.5% with scan rate varying from 5 to 500 mV s-1), revealing an advanced electrode material for high-performance supercapacitors.

  19. Anodic composite deposition of RuO₂/reduced graphene oxide/carbon nanotube for advanced supercapacitors.

    PubMed

    Hu, Chi-Chang; Wang, Chia-Wei; Chang, Kuo-Hsin; Chen, Ming-Guan

    2015-07-10

    Anodic composite deposition is demonstrated to be a unique method for fabricating a ternary ruthenium dioxide/reduced graphene oxide/carbon nanotube (RuO2 xH2O/rGO/CNT, denoted as RGC) nanocomposite onto Ti as an advanced electrode material for supercapacitors. The rGO/CNT composite in RGCs acts as a conductive backbone to facilitate the electron transport between current collector and RuO2 xH2O nanoparticles (NPs), revealed by the high total specific capacitance (C(S,T) = 808 F g(-1)) of RGC without annealing. The contact resistance among RuO2 xH2O NPs is improved by low-temperature annealing at 150 °C (RGC-150), which renders slight sintering and enhances the specific capacitance of RuO2 xH2O to achieve 1200 F g(-1). The desirable nanocomposite microstructure of RGC-150 builds up the smooth pathways of both protons and electrons to access the active oxy-ruthenium species. This nanocomposite exhibits an extremely high C(S,T) of 973 F g(-1) at 25 mV s(-1) (much higher than 435 F g(-1) of an annealed RuO2 xH2O deposit) and good capacitance retention (60.5% with scan rate varying from 5 to 500 mV s(-1)), revealing an advanced electrode material for high-performance supercapacitors.

  20. The MMP-9/TIMP-1 System is Involved in Fluoride-Induced Reproductive Dysfunctions in Female Mice.

    PubMed

    Wang, Hong-Wei; Zhao, Wen-Peng; Tan, Pan-Pan; Liu, Jing; Zhao, Jing; Zhou, Bian-Hua

    2017-08-01

    A total of 84 healthy female mice were kept with various concentrations of sodium fluoride (F) (0, 50, 100, 150 mg F - /L in drinking water for 90 days) and were then mated with healthy male mice for 1 week to study the effect of excessive fluoride on female reproductive function, particularly in embryo implantation. The rate of pregnancy, litter size, and the birth weight of female mice were evaluated. Ultrastructural changes of uteri tissues were observed by transmission electron microscopy (TEM). The mRNA expression levels of MMP-9 and TIMP-1 were determined by quantitative real-time PCR. The protein expression levels of MMP-9 and TIMP-1 were analyzed by western blotting. Results showed a significant decrease of litter size in mice exposed to fluoride. TEM images of uteri tissue of mice that underwent a 150 mg/L F - treatment for 90 days showed a vague nucleus, reduced microvilli, increased lysosomes, a dilated endoplasmic reticulum, and a vacuolization mitochondrion when compared with the control group. Following the damage of the structure, the expression levels of MMP-9 and TIMP-1 in uteri tissues were significantly unregulated in the F 150 group. These results show that MMP-9/TIMP-1 system disturbance and changes of histological structure in uteri tissue are involved in fluoride-induced reproductive dysfunctions.

  1. 30 CFR 35.22 - Test to determine effect of evaporation on flammability.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... shall be to determine the effect of evaporation on the reduction of fire resistance of a hydraulic fluid..., capable of maintaining the specified evaporation temperature constant within ±2 °F., shall be used in the... shall be inserted in the oven, that shall have been heated to a temperature of 150 °F., ±2 °F., which...

  2. 30 CFR 35.22 - Test to determine effect of evaporation on flammability.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... shall be to determine the effect of evaporation on the reduction of fire resistance of a hydraulic fluid..., capable of maintaining the specified evaporation temperature constant within ±2 °F., shall be used in the... shall be inserted in the oven, that shall have been heated to a temperature of 150 °F., ±2 °F., which...

  3. 30 CFR 35.22 - Test to determine effect of evaporation on flammability.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... shall be to determine the effect of evaporation on the reduction of fire resistance of a hydraulic fluid..., capable of maintaining the specified evaporation temperature constant within ±2 °F., shall be used in the... shall be inserted in the oven, that shall have been heated to a temperature of 150 °F., ±2 °F., which...

  4. 30 CFR 35.22 - Test to determine effect of evaporation on flammability.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... shall be to determine the effect of evaporation on the reduction of fire resistance of a hydraulic fluid..., capable of maintaining the specified evaporation temperature constant within ±2 °F., shall be used in the... shall be inserted in the oven, that shall have been heated to a temperature of 150 °F., ±2 °F., which...

  5. 33 CFR 150.628 - How must the operator label, tag, and mark a container of hazardous material?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Workplace Safety and Health Hazard Communication Program § 150.628 How must the operator label, tag, and..., reactive and other special condition hazard warnings. The only exception is for portable containers that...

  6. Boundary lubrication of formulated C-ethers in air to 300 C. 2: Organic acid additives

    NASA Technical Reports Server (NTRS)

    Jones, W. R., Jr.

    1973-01-01

    Friction and wear measurements were made on CVM M-50 steel lubricated with three C-ether (modified polyphenyl ether) formulations in dry and moist air. Results were compared to those obtained with a formulated Type 2 ester and the C-ether base fluid. A ball-on-disk sliding friction apparatus was used. Experimental conditions were a 1-kilogram load, a 17-meter/minute surface speed, and a 25 to 300 C (77 to 572 F) disk temperature range. The three C-ether formulations yielded better boundary lubricating characteristics than the Type 2 ester under most test conditions. All C-ether formulations exhibited higher friction coefficients than the ester from 150 to 300 C (302 to 572 F) and similar or lower values from 25 to 150 C (77 to 302 F).

  7. Transported Low-Temperature Geothermal Energy for Thermal End Uses Final Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Zhiyao; Liu, Xiaobing; Gluesenkamp, Kyle R

    2016-10-01

    The use of geothermal energy is an emerging area for improving the nation’s energy resiliency. Conventionally, geothermal energy applications have focused on power generation using high temperature hydrothermal resources or enhanced geothermal systems. However, many low temperature (below 150°C/300°F) geothermal resources are also available but have not been fully utilized. For example, it is estimated that 25 billion barrels of geothermal fluid (mostly water and some dissolved solids) at 176°F to 302°F (80°C to 150°C) is coproduced annually at oil and gas wells in the United States (DOE 2015). The heat contained in coproduced geothermal fluid (also referred as “coproducedmore » water”) is typically wasted because the fluid is reinjected back into the ground without extracting the heat.« less

  8. Isolation and characterization of a bacteriophage F20 virulent to Enterobacter aerogenes.

    PubMed

    Mishra, Charitra Kumar; Choi, Tae Jin; Kang, Sun Chul

    2012-10-01

    An aquatic phage, designated F20, was characterized and its physico-chemical characteristics studied. F20 was specifically virulent to only two strains of Enterobacter aerogenes (ATCC 13048 and the multi-drug-resistant strain K113) among other species tested (n = 15). It was classified in the family Siphoviridae of T1-like viruses and contained a linear dsDNA genome estimated to be 51.5 kbp enclosed by an isometric capsid of 50±2 nm in diameter and a tail of 150±3 nm in length. F20 was able to survive in a broad pH range between 4 and 11, showed potential for future animal trials using oral solution and resisted chloroform and ethanol. It exhibited remarkable stability between room temperature and 70 °C for up to 150 min, and even up to 6 months at room temperature. Knowledge of this phage belonging to the widespread T1-like viruses might be helpful for adopting therapeutic strategies against E. aerogenes.

  9. 14 CFR 135.150 - Public address and crewmember interphone systems.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... to alert flight crewmembers; (iii) For the alerting system required by paragraph (b)(7)(ii) of this... systems. 135.150 Section 135.150 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Aircraft and Equipment § 135.150 Public address and crewmember interphone systems. No person may operate an...

  10. 14 CFR 135.150 - Public address and crewmember interphone systems.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... to alert flight crewmembers; (iii) For the alerting system required by paragraph (b)(7)(ii) of this... systems. 135.150 Section 135.150 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Aircraft and Equipment § 135.150 Public address and crewmember interphone systems. No person may operate an...

  11. 14 CFR 135.150 - Public address and crewmember interphone systems.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... to alert flight crewmembers; (iii) For the alerting system required by paragraph (b)(7)(ii) of this... systems. 135.150 Section 135.150 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Aircraft and Equipment § 135.150 Public address and crewmember interphone systems. No person may operate an...

  12. 33 CFR 150.300 - What does this subpart do?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false What does this subpart do? 150.300 Section 150.300 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Vessel Navigation § 150.300 What does this subpart do...

  13. 33 CFR 150.300 - What does this subpart do?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false What does this subpart do? 150.300 Section 150.300 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Vessel Navigation § 150.300 What does this subpart do...

  14. 14 CFR 135.150 - Public address and crewmember interphone systems.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... to alert flight crewmembers; (iii) For the alerting system required by paragraph (b)(7)(ii) of this... systems. 135.150 Section 135.150 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Aircraft and Equipment § 135.150 Public address and crewmember interphone systems. No person may operate an...

  15. 14 CFR 135.150 - Public address and crewmember interphone systems.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... to alert flight crewmembers; (iii) For the alerting system required by paragraph (b)(7)(ii) of this... systems. 135.150 Section 135.150 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Aircraft and Equipment § 135.150 Public address and crewmember interphone systems. No person may operate an...

  16. 33 CFR 150.618 - What are the requirements for respiratory protection?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... respiratory protection? 150.618 Section 150.618 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF... Respiratory Protection § 150.618 What are the requirements for respiratory protection? (a) The deepwater port operator must ensure that respiratory protection measures are taken in compliance with 29 CFR 1910.134...

  17. 33 CFR 150.618 - What are the requirements for respiratory protection?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... respiratory protection? 150.618 Section 150.618 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF... Respiratory Protection § 150.618 What are the requirements for respiratory protection? (a) The deepwater port operator must ensure that respiratory protection measures are taken in compliance with 29 CFR 1910.134...

  18. 33 CFR 150.618 - What are the requirements for respiratory protection?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... respiratory protection? 150.618 Section 150.618 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF... Respiratory Protection § 150.618 What are the requirements for respiratory protection? (a) The deepwater port operator must ensure that respiratory protection measures are taken in compliance with 29 CFR 1910.134...

  19. 33 CFR 150.618 - What are the requirements for respiratory protection?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... respiratory protection? 150.618 Section 150.618 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF... Respiratory Protection § 150.618 What are the requirements for respiratory protection? (a) The deepwater port operator must ensure that respiratory protection measures are taken in compliance with 29 CFR 1910.134...

  20. 33 CFR 150.618 - What are the requirements for respiratory protection?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... respiratory protection? 150.618 Section 150.618 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF... Respiratory Protection § 150.618 What are the requirements for respiratory protection? (a) The deepwater port operator must ensure that respiratory protection measures are taken in compliance with 29 CFR 1910.134...

  1. 33 CFR 150.521 - What records are required?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false What records are required? 150.521 Section 150.521 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... Equipment § 150.521 What records are required? (a) The operator must maintain a record of each test and...

  2. GHz low noise short wavelength infrared (SWIR) photoreceivers

    NASA Astrophysics Data System (ADS)

    Bai, Xiaogang; Yuan, Ping; McDonald, Paul; Boisvert, Joseph; Chang, James; Woo, Robyn; Labios, Eduardo; Sudharsanan, Rengarajan; Krainak, Michael; Yang, Guangning; Sun, Xiaoli; Lu, Wei; McIntosh, Dion; Zhou, Qiugui; Campbell, Joe

    2011-06-01

    Next generation LIDAR mapping systems require multiple channels of sensitive photoreceivers that operate in the wavelength region of 1.06 to 1.55 microns, with GHz bandwidth and sensitivity less than 300 fW/√Hz. Spectrolab has been developing high sensitivity photoreceivers using InAlAs impact ionization engineering (I2E) avalanche photodiodes (APDs) structures for this application. APD structures were grown using metal organic vapor epitaxy (MOVPE) and mesa devices were fabricated using these structures. We have achieved low excess noise at high gain in these APD devices; an impact ionization parameter, k, of about 0.15 has been achieved at gains >20 using InAlAs/InGaAlAs as a multiplier layer. Electrical characterization data of these devices show dark current less than 2 nA at a gain of 20 at room temperature; and capacitance of 0.4 pF for a typical 75 micron diameter APD. Photoreceivers were built by integrating I2E APDs with a low noise GHz transimpedance amplifier (TIA). The photoreceivers showed a bandwidth of 1 GHz and a noise equivalent power (NEP) of 150 fW/rt(Hz) at room temperature.

  3. 33 CFR 150.602 - What occupational awareness training is required?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... HOMELAND SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Workplace Safety and Health Safety and Health (general) § 150.602 What occupational awareness training is required? (a) Each deepwater port operator must ensure that all deepwater port personnel are provided with information and...

  4. 33 CFR 150.710 - What are the requirements for supplying power to aids to navigation?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... supplying power to aids to navigation? 150.710 Section 150.710 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Aids to Navigation § 150.710 What are the requirements for supplying power to aids to navigation? The power of all...

  5. 33 CFR 150.710 - What are the requirements for supplying power to aids to navigation?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... supplying power to aids to navigation? 150.710 Section 150.710 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Aids to Navigation § 150.710 What are the requirements for supplying power to aids to navigation? The power of all...

  6. 33 CFR 150.705 - What are the requirements for maintaining and inspecting aids to navigation?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... maintaining and inspecting aids to navigation? 150.705 Section 150.705 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Aids to Navigation § 150.705 What are the requirements for maintaining and inspecting aids to navigation? (a) All...

  7. 33 CFR 150.705 - What are the requirements for maintaining and inspecting aids to navigation?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... maintaining and inspecting aids to navigation? 150.705 Section 150.705 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Aids to Navigation § 150.705 What are the requirements for maintaining and inspecting aids to navigation? (a) All...

  8. 33 CFR 150.705 - What are the requirements for maintaining and inspecting aids to navigation?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... maintaining and inspecting aids to navigation? 150.705 Section 150.705 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Aids to Navigation § 150.705 What are the requirements for maintaining and inspecting aids to navigation? (a) All...

  9. 33 CFR 150.705 - What are the requirements for maintaining and inspecting aids to navigation?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... maintaining and inspecting aids to navigation? 150.705 Section 150.705 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Aids to Navigation § 150.705 What are the requirements for maintaining and inspecting aids to navigation? (a) All...

  10. 33 CFR 150.710 - What are the requirements for supplying power to aids to navigation?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... supplying power to aids to navigation? 150.710 Section 150.710 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Aids to Navigation § 150.710 What are the requirements for supplying power to aids to navigation? The power of all...

  11. 33 CFR 150.705 - What are the requirements for maintaining and inspecting aids to navigation?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... maintaining and inspecting aids to navigation? 150.705 Section 150.705 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Aids to Navigation § 150.705 What are the requirements for maintaining and inspecting aids to navigation? (a) All...

  12. Generating an AC amplitude magnetic flux density value up to 150 μT at a frequency up to 100 kHz

    NASA Astrophysics Data System (ADS)

    Ulvr, Michal; Polonský, Jakub

    2017-05-01

    AC magnetic field analyzers with a triaxial coil probe are widely used by health and safety professionals, in manufacturing, and in service industries. For traceable calibration of these analyzers, it is important to be able to generate a stable, homogeneous reference AC magnetic flux density (MFD). In this paper, the generating of AC amplitude MFD value of 150 μT by single-layer Helmholtz type solenoid, described in previous work, was expanded up to a frequency of 100 kHz using the effect of serial resonance. A programmable capacitor array has been developed with a range of adjustable values from 50 pF to 51225 pF. In addition, the multi-layer search coil with a nominal area turns value of 1.3m2, used for adjusting AC MFD in the solenoid, has been modified by a transimpedance amplifier for use in a wider frequency range than up to 3 kHz. The possibility of using the programmable capacitor array up to 150 kHz has also been tested. An AC amplitude MFD value of 150 μT can be generated with expanded uncertainty better than 0.6% up to 100 kHz.

  13. CARBONYL SULFIDE INHALATION PRODUCES BRAIN LESIONS IN F344 RATS.

    EPA Science Inventory

    Carbonyl sulfide (COS) is an intermediate in the production of pesticides and herbicides, and is a metabolite of the neurotoxicant carbon disulfide. The potential neurotoxicity of inhaled COS was investigated in F344 rats. Male rats were exposed to 0, 75, 150, 300, or 600 ppm COS...

  14. U.S. EPA, Pesticide Product Label, SANTIMINE - 150, 01/31/1989

    EPA Pesticide Factsheets

    2011-04-21

    ... It •• ; u.1 ., l •• n •• f (h. I'",,, C •••• , 1 '" .fI' ,,, . UfO not .t' If! .,., Oil III" ., cl.'llIn~ 'h,af,1 " .... It~ .. ,of V •• , ,.t .. Of II(' ." • 14 ~n" ,"1111" Jl.", .. ...

  15. Quick, easy to prepare freeze-dried soups

    NASA Technical Reports Server (NTRS)

    Ramirez, R. V.; Larson, R. W.

    1972-01-01

    Major advantages of soups are that they totally rehydrate in less than five minutes in water at approximately 150 deg F, maintain flavor and quality stability for two weeks in a 100 F environment, and remain stable for considerably longer at ambient temperatures. They are suitable for either household or field use.

  16. 46 CFR 160.176-8 - Materials.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... °F to +150 °F). (4) Weathering resistance. Each non-metallic component which is not suitably covered... to this test. Materials that are covered when used in the lifejacket may be tested with the covering material. (6) Corrosion resistance. Each metal component must— (i) Be galvanically compatible with each...

  17. Radio-frequency oxygen-plasma-enhanced pulsed laser deposition of IGZO films

    NASA Astrophysics Data System (ADS)

    Chou, Chia-Man; Lai, Chih-Chang; Chang, Chih-Wei; Wen, Kai-Shin; Hsiao, Vincent K. S.

    2017-07-01

    We demonstrate the crystalline structures, optical transmittance, surface and cross-sectional morphologies, chemical compositions, and electrical properties of indium gallium zinc oxide (IGZO)-based thin films deposited on glass and silicon substrates through pulsed laser deposition (PLD) incorporated with radio-frequency (r.f.)-generated oxygen plasma. The plasma-enhanced pulsed laser deposition (PEPLD)-based IGZO thin films exhibited a c-axis-aligned crystalline (CAAC) structure, which was attributed to the increase in Zn-O under high oxygen vapor pressure (150 mTorr). High oxygen vapor pressure (150 mTorr) and low r.f. power (10 W) are the optimal deposition conditions for fabricating IGZO thin films with improved electrical properties.

  18. Effect of low water content in protic ionic liquid on ions electrosorption in porous carbon: application to electrochemical capacitors.

    PubMed

    Gorska, B; Timperman, L; Anouti, M; Béguin, F

    2017-05-10

    The effect of low water content (<20, 150, 1000, 10 000 ppm) in triethylammonium bis[(trifluoromethyl)sulfonyl]imide - [(C 2 H 5 ) 3 N + H][TFSI - ] - protic ionic liquid (PIL) on the performance of activated carbon (AC) electrodes as well as AC/AC electrochemical capacitors (ECs) is reported. Under negative polarization, hydrogen electrosorption onto carbon is enhanced along with the increase of water content in PIL, whereas the resulting desorption peaks are shifted to lower potential values, evidencing lower sorption energy when hydrogen is stored from moisture containing PIL. Cyclic voltammetry (CV) investigations on PIL-based ECs demonstrated that the evolution of the Stern layer nanostructure at positive and negative potentials is asymmetrical. The results revealed comparable electrochemical performance for PIL containing 150 and 1000 ppm of H 2 O, due to similar operation of the positive electrode, where [TFSI - ] anions are adsorbed in the outer Helmholtz plane, and the negative one, where hydrogen is stored through the reduction of the intermediate hydronium cation. By contrast, a cell with "dry" PIL (<20 ppm of water) displayed a distinctive operation due to hydrogen electrosorption directly through reduction of the protonated cation, and selective adsorption of [TFSI - ] anions, which occurs thanks to the high polarizability and image force (IF) created by their induced charge. Galvanostatic cycling with potential limitation (GCPL) showed comparable capacitance values whatever the water content in PILs up to 1000 ppm, yet electrochemical impedance spectroscopy (EIS) revealed higher capacitance as well as better retention at higher frequencies with the PIL containing 150 ppm of water. Hence, 150 ppm is reasoned to be an optimal value for diffusion and adsorption of ions. The nature of current collectors (aluminum or stainless steel) has a determining role in their polarization behavior, and consequently the potential range of electrodes as well as ion diffusion into the activated carbon porosity, influencing the observed capacitance values (C EIS/2.0V : 170 vs. 128 F g -1 , for Al and SSt, respectively).

  19. Calcium Prerinse before Fluoride Rinse Reduces Enamel Demineralization: An in situ Caries Study.

    PubMed

    Souza, João Gabriel S; Tenuta, Livia Maria Andaló; Del Bel Cury, Altair Antoninha; Nóbrega, Diego Figueiredo; Budin, Renan R; de Queiroz, Mateus X; Vogel, Gerald L; Cury, Jaime A

    2016-01-01

    A calcium (Ca) prerinse before a fluoride (F) rinse has been shown to increase oral F levels. We tested the anticaries effect of this combination in a dose-response in situ caries model. In a double-blind, crossover experiment, 10 volunteers carried enamel slabs in palatal appliances for 14 days, during which they rinsed twice/day with one of four rinse combinations: (1) a placebo prerinse (150 mM sodium lactate) followed by a distilled water rinse (negative control); (2) a placebo prerinse followed by a 250 ppm F rinse; (3) a placebo prerinse followed by a 1,000 ppm F rinse, or (4) a Ca prerinse (150 mM Ca, as calcium lactate) followed by a 250 ppm F rinse. Sucrose solution was dripped onto the slabs 8×/day to simulate a high cariogenic challenge. The percent surface hardness loss (%SHL) was significantly lower in the Ca prerinse used with the 250 ppm F rinse group (%SHL = 38.0 ± 21.0) when compared with the F rinse alone (%SHL = 59.5 ± 24.1) and similar to the 1,000 ppm F rinse group (%SHL = 42.0 ± 18.3). Compared with the 250 ppm F rinse, the Ca prerinse increased biofilm fluid F only twice (nonsignificant). However, it greatly increased F in biofilm solids (∼22×). The Ca prerinse had little effect on loosely or firmly bound enamel F. The results showed an increased level of protection against demineralization by the use of a Ca prerinse, which seems to be caused by the enhancement of F concentration in the biofilm. © 2016 S. Karger AG, Basel.

  20. 33 CFR 150.613 - What are the requirements for a noise monitoring and hearing protection survey?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... noise monitoring and hearing protection survey? 150.613 Section 150.613 Navigation and Navigable Waters... Workplace Safety and Health Noise and Hearing Protection § 150.613 What are the requirements for a noise monitoring and hearing protection survey? (a) The deepwater port operator must measure noise and provide...

  1. 33 CFR 150.613 - What are the requirements for a noise monitoring and hearing protection survey?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... noise monitoring and hearing protection survey? 150.613 Section 150.613 Navigation and Navigable Waters... Workplace Safety and Health Noise and Hearing Protection § 150.613 What are the requirements for a noise monitoring and hearing protection survey? (a) The deepwater port operator must measure noise and provide...

  2. 33 CFR 150.715 - What are the requirements for lights used as aids to navigation?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... lights used as aids to navigation? 150.715 Section 150.715 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Aids to Navigation § 150.715 What are the requirements for lights used as aids to navigation? (a) Each light under part 149...

  3. 33 CFR 150.715 - What are the requirements for lights used as aids to navigation?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... lights used as aids to navigation? 150.715 Section 150.715 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Aids to Navigation § 150.715 What are the requirements for lights used as aids to navigation? (a) Each light under part 149...

  4. 33 CFR 150.715 - What are the requirements for lights used as aids to navigation?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... lights used as aids to navigation? 150.715 Section 150.715 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Aids to Navigation § 150.715 What are the requirements for lights used as aids to navigation? (a) Each light under part 149...

  5. 33 CFR 150.715 - What are the requirements for lights used as aids to navigation?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... lights used as aids to navigation? 150.715 Section 150.715 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Aids to Navigation § 150.715 What are the requirements for lights used as aids to navigation? (a) Each light under part 149...

  6. 33 CFR 150.715 - What are the requirements for lights used as aids to navigation?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... lights used as aids to navigation? 150.715 Section 150.715 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Aids to Navigation § 150.715 What are the requirements for lights used as aids to navigation? (a) Each light under part 149...

  7. 47 CFR 95.1211 - Channel use policy.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... SERVICES Medical Device Radiocommunication Service (MedRadio) § 95.1211 Channel use policy. (a) The... caused to stations operating in the 400.150-406.000 MHz band in the Meteorological Aids, Meteorological... stations operating in the 400.150-406.000 MHz band in the Meteorological Aids, Meterological Satellite, or...

  8. In vitro hemolysis and buffer capacity studies with the novel marine anticancer agent kahalalide F and its reconstitution vehicle cremophor EL/ethanol.

    PubMed

    Nuijen, B; Bouma, M; Manada, C; Jimeno, J M; Bult, A; Beijnen, J H

    2001-01-01

    An in vitro biocompatibility study was performed with the pharmaceutical formulation of the investigational, marine-derived anticancer agent kahalalide F developed for early clinical studies. The pharmaceutical formulation consists of a lyophilized product containing 150 micrograms kahalalide F, 3 mg citric acid, 3 mg polysorbate 80, and 150 mg of sucrose per dosage unit, to be reconstituted with 3 mL of a mixture composed of Cremophor EL, ethanol, and water (5/5/90% v/v/v), resulting in a solution of pH 3 and to be further diluted in normal saline for infusion. The reconstituted product, infusion solutions, and Cremophor/ethanol (CE) vehicle were tested for hemolytic potential and buffer capacity. No significant hemolysis due to the kahalalide F formulation as well as the CE vehicle was found using both a static and dynamic test model. FB-ratio's (ratio of formulation solution (F) and volume of blood simulant (B) necessary to maintain physiological pH) as a measure of the buffer capacity of the kahalalide F infusion solutions examined indicated that no vascular irritation due to pH effects is expected in the intended administration schedule in the forthcoming Phase I study.

  9. Estimating new production in the equatorial Pacific Ocean at 150 deg W

    NASA Technical Reports Server (NTRS)

    Dugdale, Richard C.; Wilkerson, Frances P.; Barber, Richard T.; Chavez, Francisco P.

    1992-01-01

    A major goal of the WEC88 cruise of the R/V Wecoma to the equatorial Pacific (made in February-March 1988) was to establish rates of new production along a meridional section at 150 deg W and to compare these measured rates with the relatively high values for the equatorial Pacific that had been reported previously using indirect methods and models. Production values were obtained from the traditional approach using N-15 labeled nitrate uptake, and by using C-14 fixation values multiplied by f (proportion of new production) from various sources: from N-15 data, from a C-14 fixation-versus-f relationship, or from a nitrate-versus-f relationship. The ratios of directly measured nitrate and carbon uptake and the ratios of nitrate to nitrate plus ammonium uptake, i.e., values of f, agree well; values of f calculated from carbon uptake or from nitrate concentration are overestimates for the equatorial upwelling region. Carbon-to-nitrogen uptake ratios measured with C-14 and N-15, respectively, approximate the Redfield molar ratio, 6.6 C:N. The overall mean value of f (0.17) helps confirm the view that the low primary production in the enriched eastern equatorial Pacific is due to failure of the nitrate-uptake system.

  10. Compensation for pitch-shifted auditory feedback during the production of Mandarin tone sequences

    NASA Astrophysics Data System (ADS)

    Xu, Yi; Larson, Charles R.; Bauer, Jay J.; Hain, Timothy C.

    2004-08-01

    Recent research has found that while speaking, subjects react to perturbations in pitch of voice auditory feedback by changing their voice fundamental frequency (F0) to compensate for the perceived pitch-shift. The long response latencies (150-200 ms) suggest they may be too slow to assist in on-line control of the local pitch contour patterns associated with lexical tones on a syllable-to-syllable basis. In the present study, we introduced pitch-shifted auditory feedback to native speakers of Mandarin Chinese while they produced disyllabic sequences /ma ma/ with different tonal combinations at a natural speaking rate. Voice F0 response latencies (100-150 ms) to the pitch perturbations were shorter than syllable durations reported elsewhere. Response magnitudes increased from 50 cents during static tone to 85 cents during dynamic tone productions. Response latencies and peak times decreased in phrases involving a dynamic change in F0. The larger response magnitudes and shorter latency and peak times in tasks requiring accurate, dynamic control of F0, indicate this automatic system for regulation of voice F0 may be task-dependent. These findings suggest that auditory feedback may be used to help regulate voice F0 during production of bi-tonal Mandarin phrases.

  11. A new slip stacking RF system for a twofold power upgrade of Fermilab's Accelerator Complex

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Madrak, Robyn

    2014-05-15

    Fermilab's Accelerator Complex has been recently upgraded, in order to increase the 120 GeV proton beam power on target from about 400 kW to over 700 kW for NOvA and other future intensity frontier experiments. One of the key ingredients of the upgrade is the offloading of some Main Injector synchrotron operations - beam injection and RF manipulation called ''slip stacking'' - to the 8GeV Recycler Ring, which had until recently been used only for low-intensity antiproton storage and cooling. This required construction of two new 53 MHz RF systems for the slip-stacking manipulations. The cavities operate simultaneously at Vmore » peak ≲150 kV, but at slightly different frequencies (Δf=1260 Hz). Their installation was completed in September 2013. This article describes the novel solutions used in the design of the new cavities, their tuning system, and the associated high power RF system. First results showing effective operation of the RF system, beam capture and successful slip-stacking in the Recycler Ring are presented.« less

  12. High-temperature long-lasting stability assessment of a single-crystal diamond detector under high-flux neutron irradiation

    NASA Astrophysics Data System (ADS)

    Pilotti, R.; Angelone, M.; Marinelli, M.; Milani, E.; Verona-Rinati, G.; Verona, C.; Prestopino, G.; Montereali, R. M.; Vincenti, M. A.; Schooneveld, E. M.; Scherillo, A.; Pietropaolo, A.

    2016-11-01

    An innovative diamond detector layout is presented that is designed to operate at high temperature under intense neutron and gamma fluxes. It is made of a 500 μm “electronic grade” diamond film with 100 nm thick Ag metal contacts deposited onto each surface of the film by means of thermal evaporation. A 2 μ \\text{m} thick layer of 6LiF has been deposited on top of one of the two Ag contacts to make the detector sensitive to thermal neutrons. The device was tested at the ISIS spallation neutron source (Rutherford Appleton Laboratory, UK) using the INES beam line. The detector was continuously irradiated for 100 hours in vacuum (p = 10-5 \\text{mbar}) , exposed to a neutron flux of about 106 n cm-2 s-1 at a temperature T =150 ^\\circ \\text{C} . The aim of this experiment was to study the time dependence of the diamond detector performance while operating at high temperature under irradiation, providing a first experimental proof of reliable continuous operation for 100 hours at high temperature in a harsh environment.

  13. Production and characterization of anti-human IgG F(ab')2 antibody fragment.

    PubMed

    Valedkarimi, Zahra; Nasiri, Hadi; Aghebati-Maleki, Leili; Abdolalizadeh, Jalal; Esparvarinha, Mojghan; Majidi, Jafar

    2018-04-10

    In present study an optimized protocol for the separation of antibodies into antigen-binding fragments F(ab')2 using pepsin digestion was investigated. The production of these fragments is a consequential step in the development of medical research, treatment and diagnosis. For production of polyclonal antibody rabbit received antigen in four steps. The rabbit serum at 1/128000 dilution showed high absorbance in reaction with human IgG at the designed ELISA method. Rabbit IgG was purified by Ion-Exchange Chromatography (IEC) method. Purity was assessed by SDS-PAGE method. In non-reduced condition only one band was seen in about 150 kDa MW position and in reduced form, two bands were seen in 50 and 25 kDa MW positions. Rabbit IgG was digested by pepsin enzyme. The antibody fragments solution was applied to Gel filtration column to isolate the F(ab')2. Non-reduced SDS-PAGE for determining the purity of F(ab')2 fragment resulted in one band in 100 kDa corresponds to F(ab')2 fragment and a band in 150 kDa MW position corresponds to undigested IgG antibodies. The activities of FITC conjugated F(ab')2 fragment and commercial ones were compared using flowcytometry method. The activity results implied that the FITC conjugated- anti human F(ab')2 fragment worked as efficiently as the commercial one.

  14. 40 CFR 264.150 - State assumption of responsibility.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 25 2010-07-01 2010-07-01 false State assumption of responsibility. 264.150 Section 264.150 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND DISPOSAL...

  15. 40 CFR 422.52 - Effluent limitations and guidelines representing the degree of effluent reduction attainable by...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... not exceed— Total phosphorus (as P) 105 35 Fluoride (as F) 75 25 TSS 150 50 pH (1) (1) 1 Within the... values for 30 consecutive days shall not exceed— Total phosphorus (as P) 105 35 Fluoride (as F) 75 25 pH...

  16. 40 CFR 422.42 - Effluent limitations and guidelines representing the degree of effluent reduction attainable by...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... not exceed— Total phosphorus (as P) 105 35 Fluoride (as F) 75 25 TSS 150 50 pH (1) (1) 1 Within the... values for 30 consecutive days shall not exceed— Total phosphorus (as P) 105 35 Fluoride (as F) 75 25 pH...

  17. 40 CFR 422.52 - Effluent limitations and guidelines representing the degree of effluent reduction attainable by...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... not exceed— Total phosphorus (as P) 105 35 Fluoride (as F) 75 25 TSS 150 50 pH (1) (1) 1 Within the... values for 30 consecutive days shall not exceed— Total phosphorus (as P) 105 35 Fluoride (as F) 75 25 pH...

  18. 40 CFR 422.42 - Effluent limitations and guidelines representing the degree of effluent reduction attainable by...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... not exceed— Total phosphorus (as P) 105 35 Fluoride (as F) 75 25 TSS 150 50 pH (1) (1) 1 Within the... values for 30 consecutive days shall not exceed— Total phosphorus (as P) 105 35 Fluoride (as F) 75 25 pH...

  19. Direct growth of vanadium nitride nanosheets on carbon nanotube fibers as novel negative electrodes for high-energy-density wearable fiber-shaped asymmetric supercapacitors

    NASA Astrophysics Data System (ADS)

    Guo, Jiabin; Zhang, Qichong; Sun, Juan; Li, Chaowei; Zhao, Jingxin; Zhou, Zhenyu; He, Bing; Wang, Xiaona; Man, Ping; Li, Qiulong; Zhang, Jun; Xie, Liyan; Li, Mingxing; Yao, Yagang

    2018-04-01

    Significant efforts have been recently devoted to constructing high-performance fiber-shaped asymmetric supercapacitors. However, it is still a paramount challenge to develop high-energy-density fiber-shaped asymmetric supercapacitors for practical applications in portable and wearable electronics. This work reports a simple and efficient method to directly grow vanadium nitride nanosheets on carbon nanotube fibers as advanced negative electrodes with a high specific capacitance of 188 F/cm3 (564 mF/cm2). Taking advantage of their attractive structure, we successfully fabricated a fiber-shaped asymmetric supercapacitor device with a maximum operating voltage of 1.6 V by assembling the vanadium nitride/carbon nanotube fiber negative electrode with the Zinc-Nickel-Cobalt ternary oxides nanowire arrays positive electrode. Due to the excellent synergistic effects between positive and negative electrodes, a remarkable specific capacitance of 50 F/cm3 (150 mF/cm2) and an outstanding energy density of 17.78 mWh/cm3 (53.33 μWh/cm2) for our fiber-shaped asymmetric supercapacitor can be achieved. Furthermore, the as-assembled fiber-shaped asymmetric supercapacitor device has excellent mechanical flexibility in that 91% of the capacitance retained after bending 90° for 3000 times. Thus, this work exploits a pathway to construct high-energy-density fiber-shaped asymmetric supercapacitor for next-generation portable and wearable electronics.

  20. 33 CFR 150.605 - What are the procedures for reporting a possible workplace safety or health violation at a...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... a regulation in this part; or (b) A hazardous or unsafe working condition on any deepwater port. ... reporting a possible workplace safety or health violation at a deepwater port? 150.605 Section 150.605... DEEPWATER PORTS: OPERATIONS Workplace Safety and Health Safety and Health (general) § 150.605 What are the...

  1. 33 CFR 150.601 - What are the safety and health requirements for the workplace on a deepwater port?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... requirements for the workplace on a deepwater port? 150.601 Section 150.601 Navigation and Navigable Waters... Workplace Safety and Health Safety and Health (general) § 150.601 What are the safety and health requirements for the workplace on a deepwater port? (a) Each operator of a deepwater port must ensure that the...

  2. 33 CFR 150.805 - What reports must be sent both to a classification society and to the Coast Guard?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... of each report submitted to an authorized classification society, as defined in 46 CFR 8.100, for... a classification society and to the Coast Guard? 150.805 Section 150.805 Navigation and Navigable...: OPERATIONS Reports and Records Reports § 150.805 What reports must be sent both to a classification society...

  3. 33 CFR 150.805 - What reports must be sent both to a classification society and to the Coast Guard?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... of each report submitted to an authorized classification society, as defined in 46 CFR 8.100, for... a classification society and to the Coast Guard? 150.805 Section 150.805 Navigation and Navigable...: OPERATIONS Reports and Records Reports § 150.805 What reports must be sent both to a classification society...

  4. 33 CFR 150.609 - When is eye and face protection required?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false When is eye and face protection... SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Workplace Safety and Health Eyes and Face § 150.609 When is eye and face protection required? The operator must provide eye and face protectors...

  5. 33 CFR 150.609 - When is eye and face protection required?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false When is eye and face protection... SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Workplace Safety and Health Eyes and Face § 150.609 When is eye and face protection required? The operator must provide eye and face protectors...

  6. 33 CFR 150.619 - What are the fall arrest system requirements?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false What are the fall arrest system... SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Workplace Safety and Health Fall Arrest § 150.619 What are the fall arrest system requirements? (a) The deepwater port operator must ensure that...

  7. 33 CFR 150.619 - What are the fall arrest system requirements?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false What are the fall arrest system... SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Workplace Safety and Health Fall Arrest § 150.619 What are the fall arrest system requirements? (a) The deepwater port operator must ensure that...

  8. 33 CFR 150.619 - What are the fall arrest system requirements?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false What are the fall arrest system... SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Workplace Safety and Health Fall Arrest § 150.619 What are the fall arrest system requirements? (a) The deepwater port operator must ensure that...

  9. 33 CFR 150.619 - What are the fall arrest system requirements?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false What are the fall arrest system... SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Workplace Safety and Health Fall Arrest § 150.619 What are the fall arrest system requirements? (a) The deepwater port operator must ensure that...

  10. 33 CFR 150.619 - What are the fall arrest system requirements?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false What are the fall arrest system... SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Workplace Safety and Health Fall Arrest § 150.619 What are the fall arrest system requirements? (a) The deepwater port operator must ensure that...

  11. 33 CFR 150.609 - When is eye and face protection required?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false When is eye and face protection... SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Workplace Safety and Health Eyes and Face § 150.609 When is eye and face protection required? The operator must provide eye and face protectors...

  12. 33 CFR 150.609 - When is eye and face protection required?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false When is eye and face protection... SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Workplace Safety and Health Eyes and Face § 150.609 When is eye and face protection required? The operator must provide eye and face protectors...

  13. 33 CFR 150.609 - When is eye and face protection required?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false When is eye and face protection... SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Workplace Safety and Health Eyes and Face § 150.609 When is eye and face protection required? The operator must provide eye and face protectors...

  14. 24 CFR 964.150 - Funding tenant participation.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... serviceability, efficiency, economy and stability in the operation of the local development. The agreement must... 24 Housing and Urban Development 4 2014-04-01 2014-04-01 false Funding tenant participation. 964.150 Section 964.150 Housing and Urban Development REGULATIONS RELATING TO HOUSING AND URBAN...

  15. Long Term Mortality and Cancer Risk in Irradiated Rhesus Monkeys

    DTIC Science & Technology

    1989-01-01

    Reticuloendothelium Acute leukemia 32.7 M Electron 1.6 15.0 Subcutis (Leg) Fibrosarcoma 40.5 M Proton 55 8.0 Brain Glioblastoma 42.9 M Electron 1.6 15.0...Subcutis (Leg) Fibrosarcoma 54.3 M Proton 55 6.0 Subcutis (Leg) Fibrosarcoma 54.5 M Proton 55 6.0 Brain Glioblastoma 54.8 M Electron 1.6 15.0 Kidney...55 4.0 Brain Glioblastoma 93.5 F Proton 55 6.0 Brain Glioblastoma 99.7 M Proton Mixed 12.0 Subcutis (Leg) Fibrosarcoma 108.1 M Proton 55 6.0 Mucosa

  16. 44 CFR 16.150 - Program accessibility: Existing facilities.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...: Existing facilities. 16.150 Section 16.150 Emergency Management and Assistance FEDERAL EMERGENCY MANAGEMENT... accessibility: Existing facilities. (a) General. The agency shall operate each program or activity so that the... facilities accessible to and usable by individuals with handicaps; (2) In the case of historic preservation...

  17. 49 CFR 28.150 - Program accessibility: Existing facilities.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 1 2011-10-01 2011-10-01 false Program accessibility: Existing facilities. 28.150....150 Program accessibility: Existing facilities. (a) General. The Department shall operate each program... Department to make each of its existing facilities accessible to and usable by individuals with handicaps; (2...

  18. Durability investigation of a group of strain gage pressure transducers

    NASA Technical Reports Server (NTRS)

    Lederer, P. S.; Hilten, J. S.

    1972-01-01

    A durability investigation was conducted on a group of eighteen bonded-wire strain gage pressure transducers with ranges of 0 to 15 psig and 0 to 100 psig using an improved version of a previously developed technique. Some of the transducers were subjected to 40 million pressure cycles at a 5-Hz rate at laboratory ambient conditions, others were cycled at a temperature of 150 F (65.6 C). The largest change in sensitivity observed was 0.22% for a 100-psig transducer subjected to 40 million pressure cycles at 150 F. The largest change in zero pressure output observed was 0.91% FS for the same transducer. None of the transducers failed completely as a result of cycling at or below full scale pressure.

  19. 33 CFR 150.820 - When must a written report of casualty be submitted, and what must it contain?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... casualty be submitted, and what must it contain? 150.820 Section 150.820 Navigation and Navigable Waters... it contain? (a) In addition to the notice of casualty under § 150.815, the owner, operator, or person..., Report of Marine Accident, Injury, or Death, or in narrative form if it contains all of the applicable...

  20. 33 CFR 150.531 - How many fire pumps must be kept ready for use at all times?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false How many fire pumps must be kept ready for use at all times? 150.531 Section 150.531 Navigation and Navigable Waters COAST GUARD... Specialty Equipment Miscellaneous Operations § 150.531 How many fire pumps must be kept ready for use at all...

  1. 33 CFR 150.606 - After learning of a possible violation, what does the Officer in Charge of Marine Inspection do?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false After learning of a possible violation, what does the Officer in Charge of Marine Inspection do? 150.606 Section 150.606 Navigation and...: OPERATIONS Workplace Safety and Health Safety and Health (general) § 150.606 After learning of a possible...

  2. 33 CFR 150.606 - After learning of a possible violation, what does the Officer in Charge of Marine Inspection do?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false After learning of a possible violation, what does the Officer in Charge of Marine Inspection do? 150.606 Section 150.606 Navigation and...: OPERATIONS Workplace Safety and Health Safety and Health (general) § 150.606 After learning of a possible...

  3. Wireless Amperometric Neurochemical Monitoring Using an Integrated Telemetry Circuit

    PubMed Central

    Roham, Masoud; Halpern, Jeffrey M.; Martin, Heidi B.; Chiel, Hillel J.

    2015-01-01

    An integrated circuit for wireless real-time monitoring of neurochemical activity in the nervous system is described. The chip is capable of conducting high-resolution amperometric measurements in four settings of the input current. The chip architecture includes a first-order ΔΣ modulator (ΔΣM) and a frequency-shift-keyed (FSK) voltage-controlled oscillator (VCO) operating near 433 MHz. It is fabricated using the AMI 0.5 μm double-poly triple-metal n-well CMOS process, and requires only one off-chip component for operation. Measured dc current resolutions of ~250 fA, ~1.5 pA, ~4.5 pA, and ~17 pA were achieved for input currents in the range of ±5, ±37, ±150, and ±600 nA, respectively. The chip has been interfaced with a diamond-coated, quartz-insulated, microneedle, tungsten electrode, and successfully recorded dopamine concentration levels as low as 0.5 μM wirelessly over a transmission distance of ~0.5 m in flow injection analysis experiments. PMID:18990633

  4. Wireless amperometric neurochemical monitoring using an integrated telemetry circuit.

    PubMed

    Roham, Masoud; Halpern, Jeffrey M; Martin, Heidi B; Chiel, Hillel J; Mohseni, Pedram

    2008-11-01

    An integrated circuit for wireless real-time monitoring of neurochemical activity in the nervous system is described. The chip is capable of conducting high-resolution amperometric measurements in four settings of the input current. The chip architecture includes a first-order Delta Sigma modulator (Delta Sigma M) and a frequency-shift-keyed (FSK) voltage-controlled oscillator (VCO) operating near 433 MHz. It is fabricated using the AMI 0.5 microm double-poly triple-metal n-well CMOS process, and requires only one off-chip component for operation. Measured dc current resolutions of approximately 250 fA, approximately 1.5 pA, approximately 4.5 pA, and approximately 17 pA were achieved for input currents in the range of +/-5, +/-37, +/-150, and +/-600 nA, respectively. The chip has been interfaced with a diamond-coated, quartz-insulated, microneedle, tungsten electrode, and successfully recorded dopamine concentration levels as low as 0.5 microM wirelessly over a transmission distance of approximately 0.5 m in flow injection analysis experiments.

  5. Baltimore Zoo digester project. Final report. [Elephants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gibson, P.W.

    The results of a project to produce methane using the manure from zoo animals as a feedstock is presented. Two digesters are in operation, the first (built in 1974) utilizing wastes from the Hippo House and a second (built in 1980) utilizing wastes from the Elephant House. Demonstrations on the utilization of the gas were performed during zoo exhibits. The Elephant House Digester has a capacity of 4200 gallons and a floating gas dome which can retain at least 150 cu ft of gas. Solar energy has been incorporated into the design to maintain digester temperature at 95/sup 0/F. Themore » system produces 50 cu ft per day. After cleaning the gas, it is used to generate electricity to power an electric light, a roof fan, and an air conditioner. The gas is also used to operate a gas range and a gas lamp. During the opening day exhibit, 50 meals were cooked using the bio-gas from just 2 elephants. (DMC)« less

  6. Cell Signaling by a Novel SH2 Domain Protein that is Overexpressed with Her2 in Breast Cancer

    DTIC Science & Technology

    1998-01-01

    1990) Methods Enzymol. 185, 51. Wary, K. K, Mainiero, F ., Isakoff, S. J., Marcantonio , E. E., and Giancotti 527-537 F . G. (1996) Cell 87, 733-743...family of SH2 domain proteins and acts cell nonautonomously in excretory canal development. Dev. Biol. 184:150-164. 3. Pelicci, G., L. Lanfrancone, F ...Grignani, J. McGlade, F . Cavallo, G. Forni, I. Nicoletti, T. Pawson, and P. G. Pelicci. 1992. A novel transforming protein (SHC) with an SH2

  7. The structure of SpnF a standalone enzyme that catalyzes [4 + 2] cycloaddition

    DOE PAGES

    Fage, Christopher D.; Isiorho, Eta A.; Liu, Yungnan; ...

    2015-03-02

    In the biosynthetic pathway of the spinosyn insecticides, the tailoring enzyme SpnF performs a [4 + 2] cycloaddition on a 22-membered macrolactone to forge an embedded cyclohexene ring. To learn more about this reaction, which could potentially proceed through a Diels-Alder mechanism, in this paper we determined the 1.50-Å-resolution crystal structure of SpnF bound to S-adenosylhomocysteine. Finally, this sets the stage for advanced experimental and computational studies to determine the precise mechanism of SpnF-mediated cyclization.

  8. Impact of JAK2V617F Mutation Burden on Disease Phenotype in Chinese Patients with JAK2V617F-positive Polycythemia Vera (PV) and Essential thrombocythemia (ET).

    PubMed

    Zhao, Shixiang; Zhang, Xiang; Xu, Yang; Feng, Yufeng; Sheng, Wenhong; Cen, Jiannong; Wu, Depei; Han, Yue

    2016-01-01

    Most patients with polycythemia vera (PV) and half of essential thrombocythemia (ET) possess an activating JAK2V617F mutation. The objective of this study was to better define the effect of JAK2V617F mutant allele burden on clinical phenotypes in Chinese patients, especially thrombosis. By real-time polymerase chain reaction (RT-PCR), the JAK2V617F mutation burden was detected in 170 JAK2V617F-positive patients, including 54 PV and 116 ET. The results showed that JAK2V617F allele burden was higher in PV than in ET (P< 0.001). Higher percentage of patients had JAK2V617F allele burden over 20% in PV than in ET (68.5% VS 26.7%) (P< 0.001). In PV patients, higher JAK2V617F allele burden was observed in female (P< 0.05) and leukocytosis patients (WBC above 10 × 10(9)/L) (P< 0.001). Meanwhile, ET patients showed increased JAK2V617F allele burden in the group with higher hemoglobin (HGB above 150 g/L) (P< 0.05), leukocytosis (WBC above 10 × 10(9)/L) (P< 0.001), splenomegaly (P< 0.05) and thrombosis (P< 0.05). In conclusion, the JAK2V617F mutation allele burden is higher in Chinese patients with PV than ET. In PV patients, JAK2V617F mutation burden had influence on WBC counts. And the clinical characteristics of ET patients, such as WBC counts, hemoglobin level, splenomegaly and thrombosis, were influenced by JAK2V617F mutation burden. Male, high hemoglobin (HGB above 150 g/L), and increased JAK2V617F mutation burden (JAK2V617F allele burden ≥ 16.5%) were risks of thrombosis (P< 0.05) for ET patients by Logistic Regression.

  9. 33 CFR 150.405 - How must a cargo transfer system be tested and inspected?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false How must a cargo transfer system..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Cargo Transfer Operations § 150.405 How must a cargo transfer system be tested and inspected? (a) No person may transfer oil...

  10. 33 CFR 150.405 - How must a cargo transfer system be tested and inspected?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false How must a cargo transfer system..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Cargo Transfer Operations § 150.405 How must a cargo transfer system be tested and inspected? (a) No person may transfer oil...

  11. 33 CFR 150.405 - How must a cargo transfer system be tested and inspected?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false How must a cargo transfer system..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Cargo Transfer Operations § 150.405 How must a cargo transfer system be tested and inspected? (a) No person may transfer oil...

  12. 33 CFR 150.610 - Where must eyewash equipment be located?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false Where must eyewash equipment be located? 150.610 Section 150.610 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Workplace Safety and Health Eyes and Face...

  13. 33 CFR 150.610 - Where must eyewash equipment be located?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false Where must eyewash equipment be located? 150.610 Section 150.610 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Workplace Safety and Health Eyes and Face...

  14. 33 CFR 150.610 - Where must eyewash equipment be located?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Where must eyewash equipment be located? 150.610 Section 150.610 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Workplace Safety and Health Eyes and Face...

  15. 33 CFR 150.610 - Where must eyewash equipment be located?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false Where must eyewash equipment be located? 150.610 Section 150.610 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Workplace Safety and Health Eyes and Face...

  16. 33 CFR 150.610 - Where must eyewash equipment be located?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Where must eyewash equipment be located? 150.610 Section 150.610 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Workplace Safety and Health Eyes and Face...

  17. Spectroscopy and lasing of Tm:SrMoO4 crystal near 1.5, 1.9, and 2.3-μm under 793-nm excitation

    NASA Astrophysics Data System (ADS)

    Šulc, Jan; Švejkar, Richard; Němec, Michal; Doroshenko, Maxim E.; Jelínková, Helena; Ivleva, Liudmila I.; Dunaeva, Elizaveta E.

    2018-02-01

    The spectroscopy properties and lasing of diode pumped Tm-doped strontium molybdate SrMoO4 single crystal were investigated at room temperature. The Tm:SrMoO4 crystal was grown by modified Stepanov method (2 wt.% of TmNbO4 in the melt). The tested Tm:SrMoO4 sample was cut from the grown crystal boule perpendicularly to growth direction 100. For spectroscopy and laser experiments 4.2mm thick plane-parallel face-polished plate (without AR coatings) was used. A fiber-coupled laser diode operating at wavelength 793nm was used for longitudinal Tm:SrMoO4 pumping which corresponds to 3H4 level excitation. Fluorescence spectra measurement showed strong emission in vicinity of 1.8 μm (3F4 -> 3H6 transition), and also significant emission close to wavelengths 1.45 μm (3H4 -> 3F4 transition) and 2.3 μm (3H4 -> 3H5 transition). The lasing was successfully reached for all these three transitions and output characteristics were measured. The pumping laser diode was operating in the pulsed regime with a low duty cycle. The 145mm long semi-hemispherical laser resonator consisted of flat pumping mirror (HT @ 0.79 μm) and curved (r = 150mm) output coupler. For each lasing transition the particular set of resonator mirrors was used to reach high reflexivity of pumping mirror and output coupler transmission 0.5% at laser operation wavelength. The obtained laser emission wavelengths were 1.95 μm, 1.45 & 1.49 μm, and 2.30 μm. In spite of low laser slope efficiency in respect to absorbed pumping power (0.45% for 3H4 -> 3F4 transition, 0.50% for 3F4 -> 3H6 transition and 0.83% for 3H4 -> 3H5 transition), results obtained are promising for further development of diode-pumped laser at 2.3 μm spectral region.

  18. Thermal conductivity of fresh and irradiated U-Mo fuels

    NASA Astrophysics Data System (ADS)

    Huber, Tanja K.; Breitkreutz, Harald; Burkes, Douglas E.; Casella, Amanda J.; Casella, Andrew M.; Elgeti, Stefan; Reiter, Christian; Robinson, Adam. B.; Smith, Frances. N.; Wachs, Daniel. M.; Petry, Winfried

    2018-05-01

    The thermal conductivity of fresh and irradiated U-Mo dispersion and monolithic fuel has been investigated experimentally and compared to theoretical models. During in-pile irradiation, thermal conductivity of fresh dispersion fuel at a temperature of 150 °C decreased from 59 W/m·K to 18 W/m·K at a burn-up of 4.9·1021 f/cc and further to 9 W/m·K at a burn-up of 6.1·1021 f/cc. Fresh monolithic fuel has a considerably lower thermal conductivity of 15 W/m·K at a temperature of 150 °C and consequently its decrease during in-pile irradiation is less steep than for dispersion fuel. For a burn-up of 3.5·1021 f/cc of monolithic fuel, a thermal conductivity of 11 W/m·K at a temperature of 150 °C has been measured by Burkes et al. (2015). The difference of decrease for both fuels originates from effects in the matrix that occur during irradiation, like for dispersion fuel the gradual disappearance of the Al matrix with increased burn-up and the subsequent growth of an interaction layer (IDL) between the U-Mo fuel particle and Al matrix and subsequent matrix hardening. The growth of fission gas bubbles and the decomposition of the U-Mo crystal lattice also affect both dispersion and monolithic fuel.

  19. Kinetic characterization of glucose aerodehydrogenase from Aspergillus niger EMS-150-F after optimizing the dose of mutagen for enhanced production of enzyme

    PubMed Central

    Umbreen, Huma; Zia, Muhammad Anjum; Rasul, Samreen

    2013-01-01

    In the present study enhanced production of glucose aerodehydrogenase from Aspergillus niger has been achieved after optimizing the dose of chemical mutagen ethyl methane sulfonate (EMS) that has not been reported earlier. Different doses of mutagen were applied and a strain was developed basing upon the best production. The selected strain Aspergillus niger EMS-150-F was optimized for nutrient requirements in order to produce enzyme through fermentation and the results showed the best yield at 2% corn steep liquor (CSL), 36 hours fermentation time, pH 5, 30°C temperature, 0.3% KH2PO4, 0.3% urea and 0.06% CaCO3. The enzyme was then purified and resulted in 57.88 fold purification with 52.12% recovery. On kinetic characterization, the enzyme showed optimum activity at pH 6 and temperature 30°C. The Michaelis-Menton constants (Km, Vmax, Kcat and Kcat/Km) were 20 mM, 45.87 U mL−1, 1118.81 s−1 and 55.94 s−1 mM−1, respectively. The enzyme was found to be thermaly stable and the enthalpy and free energy showed an increase with increase in temperature and ΔS* was highly negative proving the enzyme from A. niger EMS-150-F resistant to temperature and showing a very little disorderliness. PMID:24688499

  20. Focused Schlieren flow visualization studies of multiple venturi fuel injectors in a high pressure combustor

    NASA Technical Reports Server (NTRS)

    Chun, K. S.; Locke, R. J.; Lee, C. M.; Ratvasky, W. J.

    1994-01-01

    Multiple venturi fuel injectors were used to obtain uniform fuel distributions, better atomization and vaporization in the premixing/prevaporizing section of a lean premixed/prevaporized flame tube combustor. A focused Schlieren system was used to investigate the fuel/air mixing effectiveness of various fuel injection configurations. The Schlieren system was focused to a plane within the flow field of a test section equipped with optical windows. The focused image plane was parallel to the axial direction of the flow and normal to the optical axis. Images from that focused plane, formed by refracted light due to density gradients within the flow field, were filmed with a high-speed movie camera at framing rates of 8,000 frames per second (fps). Three fuel injection concepts were investigated by taking high-speed movies of the mixture flows at various operating conditions. The inlet air temperature was varied from 600 F to 1000 F, and inlet pressures from 80 psia to 150 psia. Jet-A fuel was used typically at an equivalence ratio of 0.5. The intensity variations of the digitized Schlieren images were analytically correlated to spatial density gradients of the mixture flows. Qualitative measurements for degree of mixedness, intensity of mixing, and mixing completion time are shown. Various mixing performance patterns are presented with different configurations of fuel injection points and operating conditions.

  1. DACS II - A distributed thermal/mechanical loads data acquisition and control system

    NASA Technical Reports Server (NTRS)

    Zamanzadeh, Behzad; Trover, William F.; Anderson, Karl F.

    1987-01-01

    A distributed data acquisition and control system has been developed for the NASA Flight Loads Research Facility. The DACS II system is composed of seven computer systems and four array processors configured as a main computer system, three satellite computer systems, and 13 analog input/output systems interconnected through three independent data networks. Up to three independent heating and loading tests can be run concurrently on different test articles or the entire system can be used on a single large test such as a full scale hypersonic aircraft. Thermal tests can include up to 512 independent adaptive closed loop control channels. The control system can apply up to 20 MW of heating to a test specimen while simultaneously applying independent mechanical loads. Each thermal control loop is capable of heating a structure at rates of up to 150 F per second over a temperature range of -300 to +2500 F. Up to 64 independent mechanical load profiles can be commanded along with thermal control. Up to 1280 analog inputs monitor temperature, load, displacement and strain on the test specimens with real time data displayed on up to 15 terminals as color plots and tabular data displays. System setup and operation is accomplished with interactive menu-driver displays with extensive facilities to assist the users in all phases of system operation.

  2. Production and purification of polyclonal antibody against F(ab')2 fragment of human immunoglobulin G

    PubMed Central

    Nasiri, Hadi; Valedkarimi, Zahra; Aghebati-Maleki, Leili; Abdolalizadeh, Jalal; Kazemi, Tohid; Esparvarinha, Mojghan; Majidi, Jafar

    2017-01-01

    Antibodies are essential tools of biomedical and biochemical researches. Polyclonal antibodies are produced against different epitopes of antigens. Purified F(ab')2 can be used for animal’s immunization to produce polyclonal antibodies. Human immunoglobulin G (IgG) was purified by ion exchange chromatography method. In all stages verification method of the purified antibodies was sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE). Purified IgG was digested by pepsin enzyme and F(ab')2 fragment was purified by gel filtration separation method. For production of polyclonal antibody, rabbit was immunized by purified F(ab')2 and antibody production was investigated by enzyme-linked immunosorbent assay. Purified anti-IgG F(ab')2 was conjugated with fluorescein isothiocyanate. Ion exchange chromatography purification yielded 38 mg of human IgG antibody. The results of SDS-PAGE in reduced and non-reduced conditions showed bands with 25-30 kDa molecular weight (MW) and 50-kDa respectively and a distinct band with 150 kDa MW. The results of non-reduced SDS-PAGE for determining the purity of F(ab')2 fragment showed one band in 90 kDa and a band in 150 kDa MW position. Purification by Ion exchange chromatography method resulted about 12 mg rabbit polyclonal antibody. Flow cytometry showed generated polyclonal antibody had an acceptable activity compared to commercial antibody. Taking together, purified IgG F(ab')2 and polyclonal anti-IgG F(ab')2 are useful tools in biomedical and biochemical researches and diagnostic kits. PMID:29326789

  3. Production and purification of polyclonal antibody against F(ab')2 fragment of human immunoglobulin G.

    PubMed

    Nasiri, Hadi; Valedkarimi, Zahra; Aghebati-Maleki, Leili; Abdolalizadeh, Jalal; Kazemi, Tohid; Esparvarinha, Mojghan; Majidi, Jafar

    2017-01-01

    Antibodies are essential tools of biomedical and biochemical researches. Polyclonal antibodies are produced against different epitopes of antigens. Purified F(ab') 2 can be used for animal's immunization to produce polyclonal antibodies. Human immunoglobulin G (IgG) was purified by ion exchange chromatography method. In all stages verification method of the purified antibodies was sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE). Purified IgG was digested by pepsin enzyme and F(ab') 2 fragment was purified by gel filtration separation method. For production of polyclonal antibody, rabbit was immunized by purified F(ab') 2 and antibody production was investigated by enzyme-linked immunosorbent assay. Purified anti-IgG F(ab') 2 was conjugated with fluorescein isothiocyanate. Ion exchange chromatography purification yielded 38 mg of human IgG antibody. The results of SDS-PAGE in reduced and non-reduced conditions showed bands with 25-30 kDa molecular weight (MW) and 50-kDa respectively and a distinct band with 150 kDa MW. The results of non-reduced SDS-PAGE for determining the purity of F(ab') 2 fragment showed one band in 90 kDa and a band in 150 kDa MW position. Purification by Ion exchange chromatography method resulted about 12 mg rabbit polyclonal antibody. Flow cytometry showed generated polyclonal antibody had an acceptable activity compared to commercial antibody. Taking together, purified IgG F(ab') 2 and polyclonal anti-IgG F(ab') 2 are useful tools in biomedical and biochemical researches and diagnostic kits.

  4. Development and characterization of five rainbow trout pituitary single-cell clone lines capable of producing pituitary hormones

    USDA-ARS?s Scientific Manuscript database

    Five single-cell clone lines (mRTP1B, mRTP1E, mRTP1F, mRTP1K, and mRTP2A) have been developed from adult rainbow trout pituitary glands. These cell lines have been maintained in a CO2-independent medium supplemented with 10% fetal bovine serum (FBS) for more than 150 passages. At about 150 passages,...

  5. 33 CFR 150.35 - How may an adjacent coastal State request an amendment to the operations manual?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... provide equivalent or improved protection and safety. The adjacent coastal State may petition the... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false How may an adjacent coastal State... § 150.35 How may an adjacent coastal State request an amendment to the operations manual? (a) An...

  6. 33 CFR 150.35 - How may an adjacent coastal State request an amendment to the operations manual?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... provide equivalent or improved protection and safety. The adjacent coastal State may petition the... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false How may an adjacent coastal State... § 150.35 How may an adjacent coastal State request an amendment to the operations manual? (a) An...

  7. 33 CFR 150.35 - How may an adjacent coastal State request an amendment to the operations manual?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... provide equivalent or improved protection and safety. The adjacent coastal State may petition the... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false How may an adjacent coastal State... § 150.35 How may an adjacent coastal State request an amendment to the operations manual? (a) An...

  8. 33 CFR 150.515 - What are the requirements for weight testing of newly installed or relocated craft?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... weight testing of newly installed or relocated craft? 150.515 Section 150.515 Navigation and Navigable... testing of newly installed or relocated craft? (a) The operator must perform installation weight testing... (a) of this section, when survival crafts are relocated to another deepwater port. ...

  9. 33 CFR 150.623 - What are the requirements for protecting personnel from hazards associated with confined spaces?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... associated with entering the port's confined spaces, and develop a confined space safe entry program that... implement the confined space safe entry program, the deepwater port operator must determine the education... protecting personnel from hazards associated with confined spaces? 150.623 Section 150.623 Navigation and...

  10. 14 CFR Appendix B to Part 150 - Noise Compatibility Programs

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... (CONTINUED) AIRPORTS AIRPORT NOISE COMPATIBILITY PLANNING Pt. 150, App. B Appendix B to Part 150—Noise... compatibility program is: (1) To promote a planning process through which the airport operator can examine and... airport (for example, an evaluation of night curfews is not appropriate if there are no night flights and...

  11. 14 CFR Appendix B to Part 150 - Noise Compatibility Programs

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... (CONTINUED) AIRPORTS AIRPORT NOISE COMPATIBILITY PLANNING Pt. 150, App. B Appendix B to Part 150—Noise... compatibility program is: (1) To promote a planning process through which the airport operator can examine and... airport (for example, an evaluation of night curfews is not appropriate if there are no night flights and...

  12. 14 CFR Appendix B to Part 150 - Noise Compatibility Programs

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... (CONTINUED) AIRPORTS AIRPORT NOISE COMPATIBILITY PLANNING Pt. 150, App. B Appendix B to Part 150—Noise... compatibility program is: (1) To promote a planning process through which the airport operator can examine and... airport (for example, an evaluation of night curfews is not appropriate if there are no night flights and...

  13. 14 CFR Appendix B to Part 150 - Noise Compatibility Programs

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... (CONTINUED) AIRPORTS AIRPORT NOISE COMPATIBILITY PLANNING Pt. 150, App. B Appendix B to Part 150—Noise... compatibility program is: (1) To promote a planning process through which the airport operator can examine and... airport (for example, an evaluation of night curfews is not appropriate if there are no night flights and...

  14. 14 CFR Appendix B to Part 150 - Noise Compatibility Programs

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... (CONTINUED) AIRPORTS AIRPORT NOISE COMPATIBILITY PLANNING Pt. 150, App. B Appendix B to Part 150—Noise... compatibility program is: (1) To promote a planning process through which the airport operator can examine and... airport (for example, an evaluation of night curfews is not appropriate if there are no night flights and...

  15. Comparison of F(ab')2 versus Fab antivenom for pit viper envenomation: A prospective, blinded, multicenter, randomized clinical trial

    PubMed Central

    Ruha, Anne-Michelle; Seifert, Steven A.; Morgan, David L.; Lewis, Brandon J.; Arnold, Thomas C.; Clark, Richard F.; Meggs, William J.; Toschlog, Eric A.; Borron, Stephen W.; Figge, Gary R.; Sollee, Dawn R.; Shirazi, Farshad M.; Wolk, Robert; de Chazal, Ives; Quan, Dan; García-Ubbelohde, Walter; Alagón, Alejandro; Gerkin, Richard D.; Boyer, Leslie V.

    2015-01-01

    Background. Crotalidae Polyvalent Immune Fab (Ovine) has been the only antivenom commercially available in the US since 2007 for treatment of Crotalinae envenomation. Late coagulopathy can occur or recur after clearance of Fab antivenom, often after hospital discharge, lasting in some cases more than 2 weeks. There have been serious, even fatal, bleeding complications associated with recurrence phenomena. Frequent follow-up is required, and additional intervention or hospitalization is often necessary. F(ab')2 immunoglobulin derivatives have longer plasma half life than do Fab. We hypothesized that F(ab')2 antivenom would be superior to Fab in the prevention of late coagulopathy following treatment of patients with Crotalinae envenomation. Methods. We conducted a prospective, double-blind, randomized clinical trial, comparing late coagulopathy in snakebitten patients treated with F(ab')2 with maintenance doses [F(ab')2/F(ab')2], or F(ab')2 with placebo maintenance doses [F(ab')2/placebo], versus Fab with maintenance doses [Fab/Fab]. The primary efficacy endpoint was coagulopathy (platelet count < 150 K/mm3, fibrinogen level < 150 mg/dL) between end of maintenance dosing and day 8. Results. 121 patients were randomized at 18 clinical sites and received at least one dose of study drug. 114 completed the study. Of these, 11/37 (29.7%) in the Fab/Fab cohort experienced late coagulopathy versus 4/39 (10.3%, p < 0.05) in the F(ab')2/F(ab')2 cohort and 2/38 (5.3%, p < 0.05) in the F(ab')2/placebo cohort. The lowest heterologous protein exposure was with F(ab')2/placebo. No serious adverse events were related to study drug. In each study arm, one patient experienced an acute serum reaction and one experienced serum sickness. Conclusions. In this study, management of coagulopathic Crotalinae envenomation with longer-half-life F(ab')2 antivenom, with or without maintenance dosing, reduced the risk of subacute coagulopathy and bleeding following treatment of envenomation. PMID:25361165

  16. Comparison of F(ab')2 versus Fab antivenom for pit viper envenomation: a prospective, blinded, multicenter, randomized clinical trial.

    PubMed

    Bush, Sean P; Ruha, Anne-Michelle; Seifert, Steven A; Morgan, David L; Lewis, Brandon J; Arnold, Thomas C; Clark, Richard F; Meggs, William J; Toschlog, Eric A; Borron, Stephen W; Figge, Gary R; Sollee, Dawn R; Shirazi, Farshad M; Wolk, Robert; de Chazal, Ives; Quan, Dan; García-Ubbelohde, Walter; Alagón, Alejandro; Gerkin, Richard D; Boyer, Leslie V

    2015-01-01

    Crotalidae Polyvalent Immune Fab (Ovine) has been the only antivenom commercially available in the US since 2007 for treatment of Crotalinae envenomation. Late coagulopathy can occur or recur after clearance of Fab antivenom, often after hospital discharge, lasting in some cases more than 2 weeks. There have been serious, even fatal, bleeding complications associated with recurrence phenomena. Frequent follow-up is required, and additional intervention or hospitalization is often necessary. F(ab')2 immunoglobulin derivatives have longer plasma half life than do Fab. We hypothesized that F(ab')2 antivenom would be superior to Fab in the prevention of late coagulopathy following treatment of patients with Crotalinae envenomation. We conducted a prospective, double-blind, randomized clinical trial, comparing late coagulopathy in snakebitten patients treated with F(ab')2 with maintenance doses [F(ab')2/F(ab')2], or F(ab')2 with placebo maintenance doses [F(ab')2/placebo], versus Fab with maintenance doses [Fab/Fab]. The primary efficacy endpoint was coagulopathy (platelet count < 150 K/mm(3), fibrinogen level < 150 mg/dL) between end of maintenance dosing and day 8. 121 patients were randomized at 18 clinical sites and received at least one dose of study drug. 114 completed the study. Of these, 11/37 (29.7%) in the Fab/Fab cohort experienced late coagulopathy versus 4/39 (10.3%, p < 0.05) in the F(ab')2/F(ab')2 cohort and 2/38 (5.3%, p < 0.05) in the F(ab')2/placebo cohort. The lowest heterologous protein exposure was with F(ab')2/placebo. No serious adverse events were related to study drug. In each study arm, one patient experienced an acute serum reaction and one experienced serum sickness. In this study, management of coagulopathic Crotalinae envenomation with longer-half-life F(ab')2 antivenom, with or without maintenance dosing, reduced the risk of subacute coagulopathy and bleeding following treatment of envenomation.

  17. A Novel Slicing Method for Thin Supercapacitors.

    PubMed

    Sun, Hao; Fu, Xuemei; Xie, Songlin; Jiang, Yishu; Guan, Guozhen; Wang, Bingjie; Li, Houpu; Peng, Huisheng

    2016-08-01

    Thin and flexible supercapacitors with low cost and individual variation are fabricated by a new and efficient slicing method. Tunable output voltage and energy can be realized with a high specific capacitance of 248.8 F g(-1) or 150.8 F cm(-3) , which is well maintained before and after bending. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. 76 FR 20667 - Notice of Withdrawal of Pesticide Petitions for Residues of Pesticide Chemicals in or on Various...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-13

    ... pesticide petition (PP 8F7489) by EcoSmart Technologies, Inc., 3600 Mansell Rd., Suite 150, Alpharetta, GA... agricultural commodities. On March 9, 2010, EcoSmart Technologies, Inc., notified EPA that it was withdrawing...-HQ-OPP-2010-0092), which announced the filing of a pesticide petition (PP 9F7587) by Technology...

  19. One-step spray processing of high power all-solid-state supercapacitors

    NASA Astrophysics Data System (ADS)

    Huang, Chun; Grant, Patrick S.

    2013-08-01

    Aqueous suspensions of multi-wall carbon nanotubes (MWNTs) in dilute H2SO4 were sprayed onto both sides of a Nafion membrane and dried to fabricate flexible solid-state supercapacitors. A single cell with MWNT-only electrodes had a capacitance of 57 F g-1 per electrode at 2 mV s-1 and 44 F g-1 at 150 mV s-1 but with low H+ mobility. Cells with MWNT + ionomer hybrid electrodes showed higher H+ mobility, and the electric double layer (EDL) capacitance increased to 145 F g-1 at 2 mV s-1 and 91 F g-1 at 150 mV s-1. The energy and power densities of one electrode charged to 1 V at 1 A g-1 were 12.9 Wh kg-1 and 3.3 kW kg-1 respectively. Three solid-state supercapacitor cells connected in series charged to 3 V at 1 and 2 A g-1 provided a device power density of 8.9 kW kg-1 at 1 A g-1 and 9.4 kW kg-1 at 2 A g-1, the highest for all-solid-state EDL supercapacitors.

  20. Manpower Modeling in the Airborne Community of the United States Army.

    DTIC Science & Technology

    1984-09-01

    Inventories for CMIF 51 . . . 103 27. Authorizations and Inventories for CMF 54 . . . 104 28. Authorizations and Inventories for CMF 55 . 105 29...81 ........ 144 C.24 Transition Matrix for CMF 84 ......... 145 10 .. - C.25 Transition Matrix for CMiF 91 .... 145 C. 26 Transition matrix for CNF...150 C. 30 Transition Matrix for CM1F 97 ....... . 151 C. 31 Transition Matrix for CMiF 98 .. . .152 I. I._IRODUCTION In the last two decades, with the

  1. Bio-Inspired Metallo-Supramolecular Polymers for Combined Mechanical Properties

    DTIC Science & Technology

    2010-01-01

    3 4 5 6 0 50 100 150 200 Temp (°C) H ea t F lo w (m W ) Figure 8. DSC trace of polymer 7. 1H NMR analysis indicated complete reaction of the...static and dynamic mechanical analysis methods. 11 5. References 1. Guan, Z. Polymer International 2007, 56, 467. 2. Oberhauser, A. F ...Hansma, P. K.; Carrion-Vazques, M.; Fernandez, J. M. Proc. Natl. Acad. Sci. USA 2001, 98, 468. 3. Reif, M. Gautel, M.; Oesterhelt, F .; Fernandez, J

  2. Fluorine-Labeling as a Diagnostic for Thiol-Ligand and Gold Nanocluster Self-Assembly

    DTIC Science & Technology

    2009-01-01

    A . Chandekar, S. K. Sengupta, C . M. F . Barry, J. L . Mead and J. E. Whitten...of O ( a factor up to 2.4) relative to its C:O:S:F composition remained although the relative compositions of C , S and F were consistent with the 6:2:1...and 2-prop- anol followed by a UV-ozone treatment (Samco International, Inc., Model UV-1 UV-Ozone stripper/cleaner) of 12 min at 150 C with a 0.50 L

  3. Public-Private Ventures in Bachelor Quarters. A Solution to the Loss of Military Construction Projects. Volume 3. Appendices F, G, and H

    DTIC Science & Technology

    1990-06-01

    Appendices F , G, and H Report NA705R2 DTIC S 1LECTE AUG 0 ? 1990 June 1990 Trevor L. Neve Jordan W. Cassell Robert L. Crosslin rApt. :’ tcr pubiir" i.g4ll...Appendices F , G, and H. Volume 1 describes the findings, conclusions, and recommendations of our study of public/private ventures in the construction and...through L. NxjTj5 ii Dli. IA .j,,., .,- AL >Il( cf! . .111 APPENDIX F DEMAND VERIFICATION STUDY FOR A PROPOSED 150-ROOM PUBLIC-PRIVATE VENTURE TRANSIENT

  4. Diode pumped tunable lasers based on Tm:CaF2 and Tm:Ho:CaF2 ceramics

    NASA Astrophysics Data System (ADS)

    Šulc, Jan; Němec, Michal; Jelinková, Helena; Doroshenko, Maxim E.; Fedorov, Pavel P.; Osiko, Vyacheslav V.

    2014-02-01

    The Tm:CaF2 (4% of TmF3) and Tm:Ho:CaF2 (2% of TmF3, 0.3% of HoF3) ceramics, prepared using hot pressing, and hot formation technique had been used as an active medium of diode pumped mid-infrared tunable laser. A fibre (core diameter 400 μm, NA = 0.22) coupled laser diode (LIMO, HLU30F400-790) was used to longitudinal pumping. The laser diode was operating in the pulsed regime (6 ms pulse length, 10 Hz repetition rate). The duty-cycle 6% ensures a low thermal load even under the maximum diode pumping power amplitude 25W (ceramics samples were only air-cooled). The laser diode emission wavelength was 786 nm. The 80mm long semi-hemispherical laser resonator consisted of a flat pumping mirror (HR @ 1.85 - 2.15 μm, HT @ 0.78 μm) and a curved (r = 150mm) output coupler with a reflectivity of ˜ 98% @ 1.85 - 2.0 μm for Tm:CaF2 laser or ˜ 99.5% @ 2.0 - 2.15 μm for Ho:Tm:CaF2. Tuning of the laser was accomplished by using a birefringent filter (single 1.5mm thick quartz plate) placed inside the optical resonator at the Brewster angle. Both samples offered broad and smooth tuning possibilities in mid-IR spectral range and the lasers were continuously tunable over ˜ 100 nm. The obtained Tm:CaF2 tunability ranged from 1892 to 1992nm (the maximum output energy 1.8mJ was reached at 1952nm for absorbed pumping energy 78 mJ). In case of Tm:Ho:CaF2 laser tunability from 2016 to 2111nm was reached (the maximum output energy 1.5mJ was reached at 2083nm for absorbed pumping energy 53 mJ). Both these material are good candidates for a future investigation of high energy, ultra-short, laser pulse generation.

  5. 33 CFR 150.35 - How may an Adjacent Coastal State request an amendment to the deepwater port operations manual?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... equivalent or improved protection and safety. The Adjacent Coastal State may petition the Commandant (CG-5P... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false How may an Adjacent Coastal State...: OPERATIONS General § 150.35 How may an Adjacent Coastal State request an amendment to the deepwater port...

  6. 33 CFR 150.35 - How may an Adjacent Coastal State request an amendment to the deepwater port operations manual?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... equivalent or improved protection and safety. The Adjacent Coastal State may petition the Commandant (CG-5P... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false How may an Adjacent Coastal State...: OPERATIONS General § 150.35 How may an Adjacent Coastal State request an amendment to the deepwater port...

  7. Development of high precision and cryogenic lens holders

    NASA Astrophysics Data System (ADS)

    Reutlinger, A.; Boesz, Anton; Mottaghibonab, A.; Eckert, P.; Dubowy, M.; Gebler, H.; Grupp, F.; Geis, N.; Bode, A.; Katterloher, R.; Bender, R.

    2017-11-01

    The optical system of the Near Infrared Spectrometer and Photometer (NISP) of the EUCLID mission consists mainly of a filter and grism wheel and 4 aspherical lenses with large diameters up to 170 mm. The single lenses require a high precision positioning at the operational temperature of 150 K. An additional design driver represents the CaF2 material of a lens, which is very sensitive wrt brittleness. The technical maturity of the combination of single features such as CaF2, large diameter (and mass), high precision and cryogenic conditions is considered as low. Therefore, a dedicated pre-development program has been launched to design and develop a first prototype of lens holder and to demonstrate the functional performance at representative operational conditions. The 4 lenses are divided into 3x lenses for the Camera Lens Assembly (CaLA) and 1x lens for the Corrector Lens Assembly (CoLA). Each lens is glue mounted onto solid state springs, part of an adaption ring. The adaption ring shall provide protection against vibration loads, high accuracy positioning, as well as quasi load free mounting of the lens under operational conditions. To reduce thermomechanical loads on the lens, the CTE of the adaption ring is adapted to that of the lens. The glue between lens and solid state spring has to withstand high tension loads during vibration. At the operational temperature the deviating CTE between glue and lens/adaption ring introduces shear loads into the glue interface, which are critical, in particular for the fragile CaF2 lens material. For the case of NISP the shear loads are controlled with the glue pad diameter and the glue thickness. In the context of the development activity many technology aspects such as various solid state spring designs, glue selection and glue handling have been investigated. A parametric structural model was developed to derive the specific design feature of each ring, such as spring force, number of springs, eigenfrequency, etc. This paper presents the design of the adaption ring in conjunction with test results from functional verification. These results are presented on behalf of the EUCLID consortium.

  8. Validation of Thermal Lethality against Salmonella enterica in Poultry Offal during Rendering.

    PubMed

    Jones-Ibarra, Amie-Marie; Acuff, Gary R; Alvarado, Christine Z; Taylor, T Matthew

    2017-09-01

    Recent outbreaks of human disease following contact with companion animal foods cross-contaminated with enteric pathogens, such as Salmonella enterica, have resulted in increased concern regarding the microbiological safety of animal foods. Additionally, the U.S. Food and Drug Administration Food Safety Modernization Act and its implementing rules have stipulated the implementation of current good manufacturing practices and food safety preventive controls for livestock and companion animal foods. Animal foods and feeds are sometimes formulated to include thermally rendered animal by-product meals. The objective of this research was to determine the thermal inactivation of S. enterica in poultry offal during rendering at differing temperatures. Raw poultry offal was obtained from a commercial renderer and inoculated with a mixture of Salmonella serovars Senftenberg, Enteritidis, and Gallinarum (an avian pathogen) prior to being subjected to heating at 150, 155, or 160°F (65.5, 68.3, or 71.1°C) for up to 15 min. Following heat application, surviving Salmonella bacteria were enumerated. Mean D-values for the Salmonella cocktail at 150, 155, and 160°F were 0.254 ± 0.045, 0.172 ± 0.012, and 0.086 ± 0.004 min, respectively, indicative of increasing susceptibility to increased application of heat during processing. The mean thermal process constant (z-value) was 21.948 ± 3.87°F. Results indicate that a 7.0-log-cycle inactivation of Salmonella may be obtained from the cumulative lethality encountered during the heating come-up period and subsequent rendering of raw poultry offal at temperatures not less than 150°F. Current poultry rendering procedures are anticipated to be effective for achieving necessary pathogen control when completed under sanitary conditions.

  9. Research into Surface Wave Phenomena in Sedimentary Basins.

    DTIC Science & Technology

    1981-12-31

    150 km of the southerly extension of the Overthrust Belt, 350 km of the Green River Basin paralleling the Uinta Mountains and 150 km across the Front...WEIDLINGER ASSOCIATES O300 SAND HiLL ROAD BUILDING 4, SUITE 245 MENLO PARK, CALIFORNIA 9462 RESEARCH INTO SURFACE WAVE PHENOMENA IN SEDIMENTARY BASINS BY...PARK, CALIFORNIA 94025 ! I RESEARCH INTO SURFACE WAVE PHENOMENA IN SEDIMENTARY BASINS I Dy G.L. Wojcik J. Isenberg F. Ma E. Richardson Prepared for

  10. F-16 Task Analysis Criterion-Referenced Objective and Objectives Hierarchy Report. Volume 4

    DTIC Science & Technology

    1981-03-01

    Initiation cues: Engine flameout Systems presenting cues: Aircraft fuel, engine STANDARD: Authority: TACR 60-2 Performance precision: TD in first 1/3 of...task: None Initiation cues: On short final Systems preventing cues: N/A STANDARD: Authority: 60-2 Performance precision: +/- .5 AOA; TD zone 150-1000...precision: +/- .05 AOA; TD Zone 150-1000 Computational accuracy: N/A ... . . ... . ... e e m I TASK NO.: 1.9.4 BEHAVIOR: Perform short field landing

  11. The relationships between odd- and branched-chain fatty acids to ruminal fermentation parameters and bacterial populations with different dietary ratios of forage and concentrate.

    PubMed

    Zhang, Y; Liu, K; Hao, X; Xin, H

    2017-12-01

    The objectives of this study were to investigate the effect of different dietary ratios of forage and concentrate (F:C) on ruminal odd- and branched-chain fatty acids (OBCFAs) contents and to evaluate the relationships between OBCFA and ruminal fermentation parameters as well as bacterial populations tested by real-time PCR technique. The experimental design was a 3 × 3 Latin square. Three rumen-fistulated dry Holstein cows were fed three rations with different dietary F:C ratios (F:C; 30:70, 50:50 and 70:30). The rumen samples were collected every two hours (0600, 0800, 1000, 1200, 1400, 1600, 1800, 2000, 2200, 2400, 0200 and 0400 h) over three consecutive days in each sampling period. The results showed that rumen OBCFA profiles are significantly (p < 0.05) affected by the dietary F:C ratios. The concentrations of C11:0, C13:0, iso-C15:0, iso-C16:0, iso-C17:0 and C17:0 were higher in the cows fed dietary F:C ratio of 70:30 than those fed with other two rations. However, the concentrations of anteiso-C15:0, C15:0 and total OBCFA were on the lowest level in the high forage diet. Correlation and regression analysis showed that ruminal OBCFAs had strong relationships with ruminal fermentation parameters and bacterial populations. In particular, the iso-fatty acids had potential power to predict butyrate and isoacids metabolized in the rumen, whereas the fatty acids with 17 carbon atoms correlated with ruminal NH 3 -N content. The OBCFA contents have different relationships with fibrolytic and starch bacteria in the rumen. C17:0 and its isomers might be used to predict populations of fibrolytic bacteria. Journal of Animal Physiology and Animal Nutrition © 2016 Blackwell Verlag GmbH.

  12. Low and Mid-Latitude Ionospheric Irregularities Studies Using TEC and Radio Scintillation Data from the CITRIS Radio Beacon Receiver in Low-Earth-Orbit

    NASA Astrophysics Data System (ADS)

    Siefring, C. L.; Bernhardt, P. A.; Huba, J.; Krall, J.; Roddy, P. A.

    2009-12-01

    Unique data on ionospheric plasma irregularities from the Naval Research Laboratory (NRL) CITRIS (Scintillation and TEC Receiver in Space) instrument will be presented. CITRIS is a multi-band receiver that recorded TEC (Total Electron Content) and radio scintillations from Low-Earth Orbit (LEO) on STPSat1. The 555+/5 km altitude 35° inclination orbit covers low and mid-latitudes. The measurements require propagation from a transmitter to a receiver through the F-region plasma. CITRIS used both 1) satellite beacons in LEO, such as the NRL CERTO (Coherent Electromagnetic Radio TOmography) beacons and 2) the global network of ground-based DORIS (Doppler Orbitography and Radiopositioning Integrated by Satellite) beacons. The TEC measurements allow for tracking of ionospheric disturbances and irregularities while the measurements of scintillations can simultaneously characterize their effects. CITRIS was operated in a complementary fashion with the C/NOFS (Communication/Navigations Outages Forecasting System) satellite during most of its first year of operations. C/NOFS carries a three-frequency 150/400/1067 MHz CERTO beacon and is dedicated to the study of Spread-F. In the case of Spread-F, ionospheric irregularities start with large scale size density gradients (100s of km) and cascade through complex processes to short scale sizes (10s of meters). It is typically the 100m-1km scale features that harm communication and navigation systems through scintillations. A multi-sensor approach is needed to completely understand this complex system, such as, the combination of CITRIS remote radio sensing and C/NOFS in-situ data. Several types of irregularities have been studied including Spread-F and the newly discovered dawn-side depletions. Comparisons with the physics based SAMI3 model are being performed to help our understanding of the morphology of the irregularities.

  13. 17 CFR 150.1 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    .... (f) Futures-equivalent means an option contract which has been adjusted by the previous day's risk factor, or delta coefficient, for that option which has been calculated at the close of trading and...

  14. 17 CFR 150.1 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    .... (f) Futures-equivalent means an option contract which has been adjusted by the previous day's risk factor, or delta coefficient, for that option which has been calculated at the close of trading and...

  15. Primary, new and export production in the NW Pacific subarctic gyre during the vertigo K2 experiments

    NASA Astrophysics Data System (ADS)

    Elskens, M.; Brion, N.; Buesseler, K.; Van Mooy, B. A. S.; Boyd, P.; Dehairs, F.; Savoye, N.; Baeyens, W.

    2008-07-01

    This paper presents results on tracer experiments using 13C and 15N to estimate uptake rates of dissolved inorganic carbon (DIC) and nitrogen (DIN). Experiments were carried out at station K2 (47°N, 161°E) in the NW Pacific subarctic gyre during July-August 2005. Our goal was to investigate relationships between new and export production. New production was inferred from the tracer experiments using the f ratio concept (0-50 m); while export production was assessed with neutrally buoyant sediment traps (NBSTs) and the e ratio concept (at 150 m). During trap deployments, K2 was characterized both by changes in primary production (523-404 mg C m -2 d -1), new production (119-67 mg C m -2 d -1), export production (68-24 mg C m -2 d -1) and phytoplankton composition (high to low proportion of diatoms). The data indicate that 17-23% of primary production is exportable to deeper layers ( f ratio) but only 6-13% collected as a sinking particle flux at 150 m ( e ratio). Accordingly, >80% of the carbon fixed by phytoplankton would be mineralized in the upper 50 m (1- f), while <11% would be within 50-150 m ( f- e). DIN uptake flux amounted to 0.5 mM m -2 h -1, which was equivalent to about 95% particulate nitrogen (PN) remineralized and/or grazed within the upper 150 m. Most of the shallow PN remineralization occurred just above the depth of the deep chlorophyll maximum (DCM), where a net ammonium production was measured. Below the DCM, while nitrate uptake rates became negligible because of light limitation, ammonium uptake did continue to be significant. The uptake of ammonium by heterotrophic bacteria was estimated to be 14-17% of the DIN assimilation. Less clear are the consequences of this uptake on the phytoplankton community and biogeochemical processes, e.g. new production. It was suggested that competition for ammonium could select for small cells and may force large diatoms to use nitrate. This implies that under Fe stress as observed here, ammonium uptake is preferred and new production progressively suppressed despite the surplus of nitrate.

  16. 33 CFR 150.612 - What footwear is required?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Workplace Safety and Health Feet § 150.612 What..., or engaged in activities, where there is a reasonable probability for foot injury to occur, they wear...

  17. Hubble Space Telescope far-ultraviolet imaging of the jet in 3C273: a common emission component from optical to X-rays

    NASA Astrophysics Data System (ADS)

    Jester, Sebastian; Meisenheimer, Klaus; Martel, André R.; Perlman, Eric S.; Sparks, William B.

    2007-09-01

    We present far-ultraviolet (far-UV) observations at ~150 nm of the jet of quasar 3C273 obtained with the Advanced Camera for Surveys (ACS) Solar Blind Channel onboard the Hubble Space Telescope. While the jet morphology is very similar to that in the optical and near-UV, the spectral energy distributions of the jet's subregions show an upturn in νfν at 150nm compared to 300nm everywhere in the jet. Moreover, the 150-nm flux is compatible with extrapolating the X-ray power law down to the UV region. This constitutes strong support for a common origin of the jet's far-UV and X-ray emission. It implies that even a substantial fraction of the visible light in the X-ray brightest parts of the jet arises from the same spectral component as the X-rays, as had been suggested earlier based on Spitzer Space Telescope observations. We argue that the identification of this UV/X-ray component opens up the possibility to establish the synchrotron origin of the X-ray emission by optical polarimetry. Based on observations made with the NASA/ESA Hubble Space Telescope (HST), obtained at the Space Telescope Science Institute, which is operated by the Association of Universities for Research in Astronomy, Inc., under NASA contract NAS 5-26555. These observations are associated with HST programme GO-9814. This work was begun at the Particle Astrophysics Center, Fermilab, Batavia, IL 60510, USA. ‡ E-mail: jester@mpia.de

  18. X-ray Irradiation Control of Frankliniella occidentalis and Frankliniella intonsa (Thysanoptera: Thripidae) in the Exportation of Freshly Cut Lily Flowers.

    PubMed

    Koo, Hyun-Na; Yun, Seung-Hwan; Kim, Hyun-Ju; Kim, Hyun Kyung; Kim, Gil-Hah

    2017-04-01

    Lily (Lilium longiflorum Thunb.) is the most representative bulb flower, and it is the third most important flower in the flower industry of South Korea after rose and chrysanthemum. To determine the efficacy of X-ray irradiation for use in quarantine processing, two species of flower thrips (Frankliniella intonsa (Trybom) and Frankliniella occidentalis (Pergande)) were placed in the top, middle, and bottom locations of lily boxes and irradiated with different X-ray doses. After irradiation with an X-ray dose of 150 Gy, the egg hatching of the two flower thrips was completely inhibited at every location in the lily boxes, and the irradiated F. intonsa and F. occidentalis nymphs failed to emerge as adult in every location of the lily boxes. When the adults were irradiated at 150 Gy, the fecundity of the two flower thrips was markedly lower than that of the untreated control groups. The F1 generation failed to hatch at the top and middle locations, whereas the F1 generation of both F. intonsa and F. occidentalis was not suppressed at the bottom locations, even at 200 Gy. However, hatching was perfectly inhibited at 300 Gy of X-ray irradiation. Also, X-rays did not affect the postharvest physiology of cut lilies. Therefore, a minimum dose of 300 Gy is recommended for the control of F. intonsa and F. occidentalis for the exportation of lily. © The Authors 2017. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. Mineralogy and composition of matrix and chondrule rims in carbonaceous chondrites

    NASA Technical Reports Server (NTRS)

    Zolensky, Michael; Barrett, Ruth; Browning, Lauren

    1993-01-01

    The degree of compositional variation of fine-grained minerals displayed by the members within any carbonaceous chondrite group (i.e., CI, CM, CV, CR) is a direct reflection of the range of aqueous alteration assemblages present. Matrix and fine-grained chondrule rims within any particular carbonaceous chondrite are mineralogically nearly identical to one another, but not necessarily similar in bulk elemental composition, even though they have subsequently experienced postaccretional secondary processing (aqueous alteration) under identical conditions. We propose that CO chondrites experienced parent body conditions of low f(O2), low water/rock ratios, and temperatures below 50 C. CR chondrites experienced higher water/rock ratios, potentially higher temperatures (not above 150 C), and a wide range of f(O2). The alteration mineralogy of CV chondrites indicates water/rock ratios at the high end (at least) of the range for CR chondrites, Essebi, and MAC 87300. CM chondrites experienced temperatures below 50 C, low f(O2) and low water/rock ratios, except EET 83334, which probably experienced relatively higher f(O2), and B-7904 and Y-86720, which experienced postalteration temperatures in the range 500-700 C. Most CI chondrites experienced temperatures between 50 and 150 C, relatively high water/rock ratios, and variable f(O2). Y-82162 witnessed postalteration heating, possibly as high as 400 C.

  20. 30 CFR 18.23 - Limitation of external surface temperatures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES Construction... external surfaces of mechanical or electrical components shall not exceed 150 °C. (302 °F.) under normal...

  1. 46 CFR 168.05-5 - Application of passenger vessel inspection regulations.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... applying to passenger vessels in subchapters E (Load Lines), F (Marine Engineering), H (Passenger Vessels), J (Electrical Engineering), K (Small Passenger Vessels Carrying More Than 150 Passengers Or With...

  2. 46 CFR 168.05-5 - Application of passenger vessel inspection regulations.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... applying to passenger vessels in subchapters E (Load Lines), F (Marine Engineering), H (Passenger Vessels), J (Electrical Engineering), K (Small Passenger Vessels Carrying More Than 150 Passengers Or With...

  3. 46 CFR 168.05-5 - Application of passenger vessel inspection regulations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... applying to passenger vessels in subchapters E (Load Lines), F (Marine Engineering), H (Passenger Vessels), J (Electrical Engineering), K (Small Passenger Vessels Carrying More Than 150 Passengers Or With...

  4. 46 CFR 168.05-5 - Application of passenger vessel inspection regulations.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... applying to passenger vessels in subchapters E (Load Lines), F (Marine Engineering), H (Passenger Vessels), J (Electrical Engineering), K (Small Passenger Vessels Carrying More Than 150 Passengers Or With...

  5. Effects of the in-medium nucleon-nucleon cross section on collective flow and nuclear stopping in heavy-ion collisions in the Fermi-energy domain

    NASA Astrophysics Data System (ADS)

    Li, Pengcheng; Wang, Yongjia; Li, Qingfeng; Guo, Chenchen; Zhang, Hongfei

    2018-04-01

    With the newly updated version of the ultrarelativistic quantum molecular dynamics (UrQMD) model, a systematic investigation of the effects of in-medium nucleon-nucleon (NN ) elastic cross section on the collective flow and the stopping observables in 197Au+197Au collisions at beam energies from 40 to 150 MeV/nucleon is performed. Simulations with the medium correction factors F =σNN in -medium/σNN free=0.2 ,0.3 ,0.5 and the one obtained with the FU3FP1 parametrization which depends on both the density and the momentum are compared to the FOPI and INDRA experimental data. It is found that, to best fit the experimental data of the slope of the directed flow and the elliptic flow at midrapidity as well as the nuclear stopping, the correction factors of F =0.2 and 0.5 are required for reactions at beam energies of 40 and 150 MeV/nucleon, respectively. Whereas calculations with the FU3FP1 parametrization can simultaneously reproduce these experimental data reasonably well. And, the observed increasing nuclear stopping with increasing beam energy in experimental data can also be reproduced by using the FU3FP1 parametrization, whereas the calculated stopping power in Au + Au collisions with beam energies from 40 to 150 MeV /nucleon almost remains constant when taking F equal to a fixed value.

  6. Thermal conductivity of fresh and irradiated U-Mo fuels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huber, Tanja K.; Breitkreutz, Harald; Burkes, Douglas E.

    The thermal conductivity of fresh and irradiated U-Mo dispersion and monolithic fuel has been investigated experimentally and compared to theoretical models. During in-pile irradiation, the thermal conductivity of fresh dispersion fuel at a temperature of 150°C decreases from 59 W/m ·K down to 18  W/m ·K at a burn-up of 4.9 ·10 21 f/cc and further down to 9 W/m·K at a burn-up of 6.1·10 21 f/cc. Fresh monolithic fuel has a considerably lower thermal conductivity of 15 W/m·K at a temperature of 150 °C and consequently its decrease during in-pile irradiation is less steep as for the dispersion fuel. For a burn-up ofmore » 3.5·10 21 f /cc of monolithic fuel 11 W/m·K at a temperature of 150 °C has been measured by Burkes et al. The difference of the decrease of both fuels originates from effects in the matrix that occur during irradiation, like for dispersion fuel the gradual disappearance of the Al matrix with increasing burn-up and the subsequent growth of an interaction layer (IDL) between the U-Mo fuel particle and Al matrix and subsequent matrix hardening. The growth of fission gas bubbles and the decomposition of the U-Mo crystal lattice affects both dispersion and monolithic fuel.« less

  7. A Nonlinear Model Predictive Control Algorithm for Obstacle Avoidance in Autonomous Ground Vehicles within Unknown Environments

    DTIC Science & Technology

    2015-04-24

    xs , ys , xe , ye ) double EndPo in t s [L...Distribution Statement A. Approved for public release. #26161 350 400 450 100 150 200 250 300 350 400 450 500 550 600 x (m) y (m ) Start Target U0 = 10...longitudinal speed 350 400 450 100 150 200 250 300 350 400 450 500 550 600 x (m) y (m ) Start Target (a) Trajectory 0 5 10 15 0 1 t (s) f ( U0 = 30

  8. Inventory of File gfs.t06z.wafs_grb45f06.nouswafs.grib

    Science.gov Websites

    Wind [m/s] 004 100 mb VGRD 6 hour fcst V-Component of Wind [m/s] 005 125 mb HGT 6 hour fcst Wind [m/s] 008 125 mb VGRD 6 hour fcst V-Component of Wind [m/s] 009 150 mb HGT 6 hour fcst Wind [m/s] 012 150 mb VGRD 6 hour fcst V-Component of Wind [m/s] 013 175 mb HGT 6 hour fcst

  9. Prospective Study on the Role of C-Reactive Protein (CRP) in Patients with an Acute Abdomen

    PubMed Central

    Salem, TA; Molloy, RG; O'Dwyer, PJ

    2007-01-01

    INTRODUCTION C-reactive protein (CRP) is used routinely in many hospitals to evaluate patients with an acute abdomen. We assessed CRP levels in non-specific abdominal pain (NSAP) and surgical conditions requiring operative or non-operative intervention. The aim of this study was to identify a level of CRP that can be useful in differentiating these three groups. PATIENTS AND METHODS All patients older than 25 years and admitted with acute abdominal pain other than those requiring emergency surgery were included. CRP within 24 h was assessed in all patients. Various cut-off values (< 6, > 6–50, > 50–100, > 100–150 and > 150 mg/l) were used to identify a useful diagnostic level of CRP in the 3 groups. RESULTS A total of 211 patients were prospectively evaluated – 129 women and 82 men with a mean age of 62.4 years (range, 27–92 years). CRP was performed in 196 within 24 h of admission. Sixty had NSAP while 136 had a surgical condition, of whom 69 had an operation/intervention while the rest were treated non-operatively. The median and interquartile (IQ) range for the three groups were: NSAP, 16 mg/l and 7.75–85.75 mg/l; surgical non-operative group, 75 mg/l and 30.5–150 mg/l; and surgical-operative, 111 mg/l and 42–212 mg/l, respectively. These results were statistically significant (P = 0.001). NSAP was diagnosed in 61% of patients at levels < 6 mg/l compared to 39% of patients in the surgical groups. At levels > 150 mg/l, NSAP was diagnosed in 15% of patients compared to only 54% and 31% for the operative and non-operative groups, respectively. CONCLUSIONS Despite statistically significant differences between the three groups, no useful level of CRP could be identified to differentiate between patients with NSAP and those requiring operative or non-operative management. PMID:17394705

  10. A Fiber-Optic Interferometric Tri-Component Geophone for Ocean Floor Seismic Monitoring

    PubMed Central

    Chen, Jiandong; Chang, Tianying; Fu, Qunjian; Lang, Jinpeng; Gao, Wenzhi; Wang, Zhongmin; Yu, Miao; Zhang, Yanbo; Cui, Hong-Liang

    2016-01-01

    For the implementation of an all fiber observation network for submarine seismic monitoring, a tri-component geophone based on Michelson interferometry is proposed and tested. A compliant cylinder-based sensor head is analyzed with finite element method and tested. The operation frequency ranges from 2 Hz to 150 Hz for acceleration detection, employing a phase generated carrier demodulation scheme, with a responsivity above 50 dB re rad/g for the whole frequency range. The transverse suppression ratio is about 30 dB. The system noise at low frequency originated mainly from the 1/f fluctuation, with an average system noise level −123.55 dB re rad/Hz ranging from 0 Hz to 500 Hz. The minimum detectable acceleration is about 2 ng/Hz, and the dynamic range is above 116 dB. PMID:28036011

  11. A Conceptual Design Study of a High Temperature Solar Thermal Receiver

    NASA Technical Reports Server (NTRS)

    Robertson, C. S.; Ehde, C. L.; Stacy, L. E.; Abujawdeh, S. S.; Narayanan, R.; Mccreight, L. R.; Gatti, A.; Rauch, H. W., Sr.

    1980-01-01

    A conceptual design was made for a solar thermal receiver capable of operation in the 1095 to 1650 C (2000 to 3000 F) temperature range. This receiver is designed for use with a two-axis paraboloidal concentrator in the 25 to 150 kW sub t power range, and is intended for industrial process heat, Brayton engines, or chemical/fuels reactions. Three concepts were analyzed parametrically. One was selected for conceptual design. Its key feature is a helical coiled tube of sintered silicon nitride which serves as the heat exchanger between the incident solar radiation and the working fluid. A mechanical design of this concept was prepared, and both thermal and stress analysis performed. The analysis showed good performance, low potential cost in mass production, and adaptability to both Brayton cycle engines and chemical/fuels production.

  12. Fluoride or/and aluminum induced toxicity in guinea pig teeth with the low expression of dentine phosphoprotein.

    PubMed

    Han, Tianlong; Wang, Min; Cao, Chunfang; Chen, Huacheng; Zhang, Guanghe; Wang, Liping; Wang, Jundong

    2017-08-01

    This study investigated the damage and expression of dentine phosphoprotein (DPP) in guinea pig teeth by the administration of fluoride (F) or/and aluminum (Al). Fifty-two guinea pigs were divided randomly into four groups (control, F, Al, and F+Al). F (150 mg NaF/L) or/and Al (300 mg AlCl 3 /L) were added in their drinking water for 90 days. The levels of F ion, dentine sialophosphoprotein (DSPP) gene, and DPP protein in incisor and molar were determined, respectively. The results showed that the concentrations of F ion in F and F+Al groups were increased significantly. F induced the mottled enamel and irregular abrasion of teeth, which might occur as a consequence of depressed DSPP mRNA and DPP protein expression. Both the gene and protein expressions showed obvious decrease induced by Al, especially by F. There were no synergistic effects between F and Al, instead, Al inhibited the toxicity of F. © 2017 Wiley Periodicals, Inc.

  13. Evaluation of eddy-current proximity devices for measuring thin potassium film thicknesses

    NASA Technical Reports Server (NTRS)

    Asadourian, A. S.

    1972-01-01

    Two eddy current proximity probe systems were tested over a range of 0 to 508 micrometers (0 to 20 mils) of simulated potassium film thicknesses for simulated temperatures of 66 C (150 F), 232 C (450 F), and 666 C (1230 F). The results of short time calibration tests are presented. Instrument drift was a problem throughout the testing and, without correction, may limit the use of such systems to short periods of time. Additional development will be required prior to their being usable as practical instrumentation systems.

  14. Development of Fuel Hose for Use in the Arctic.

    DTIC Science & Technology

    1983-12-01

    Teonsil* Strength. psi (min) 1500 1500 AST" D-412 eStress (100% elongation), psi record record AST4 D-412 .Ultimate Elongation, t (min) I(i 150 ASTM D-412...0.5 hr 94 hras + 0.5 hr AST14 D-47173.40F + 3.60F for: - - .Tensile Strength Retained, % (min) 60 40 ASTM D-471 eStress (1001 elongation) Retained...or fracture at -600 F, it was stiff. Moreover, it was very difficult to process and a cure temperature in excess of 302OF is necessary. Present hose

  15. Field solar degradation of pesticides and emerging water contaminants mediated by polymer films containing titanium and iron oxide with synergistic heterogeneous photocatalytic activity at neutral pH.

    PubMed

    Mazille, F; Schoettl, T; Klamerth, N; Malato, S; Pulgarin, C

    2010-05-01

    Photocatalytic degradation of phenol, nalidixic acid, mixture of pesticides, and another of emerging contaminants in water was mediated by TiO(2) and iron oxide immobilized on functionalized polyvinyl fluoride films (PVF(f)-TiO(2)-Fe oxide) in a compound parabolic collector (CPC) solar photoreactor. During degradation, little iron leaching (<0.2mgL(-1)) was observed. Phenol was efficiently degraded and mineralized at operational pH<5 and nalidixic acid degradation was complete even at pH 7, but mineralization stopped at 35%. Pesticide mixture was slowly degraded (50%) after 150min of irradiation. Degradation of the emergent contaminant mixture was successful for eight compounds and less efficient for six other compounds. The significant reactivity differences between tested compounds were assigned to the differences in structure namely that the presence of complexing or chelating groups enhanced the rates. PVF(f)-TiO(2)-Fe oxide photoactivity gradually increased during 20 days of experiments. X-ray photoelectron spectroscopy (XPS) measurements revealed significant changes on the catalyst surface. These analyses confirm that during photocatalysis mediated by PVF(f)-TiO(2)-Fe oxide, some iron leaching led to enlargement of the TiO(2) surface exposed to light, increasing its synergy with iron oxides and leading to enhanced pollutant degradation.

  16. Cryogenic Eyesafer Laser Optimization for Use Without Liquid Nitrogen

    DTIC Science & Technology

    2014-02-01

    liquid cryogens. This calls for optimal performance around 125–150 K—high enough for reasonably efficient operation of a Stirling cooler. We...state laser system with an optimum operating temperature somewhat higher—ideally 125–150 K—can be identified, then a Stirling cooler can be used to...needed to optimize laser performance in the desired temperature range. This did not include actual use of Stirling coolers, but rather involved both

  17. Removing freon gas from hydraulic fluid

    NASA Technical Reports Server (NTRS)

    Williams, B. B.; Mitchell, S. M.; State, T. S.

    1981-01-01

    Dissolved freon gas is removed from hydraulic fluid by raising temperature to 150 F and bubbling dry nitrogen gas through it, even while fluid circulates through hydraulic system. Procedure reduces parts corrosion, sludge formation, and contamination.

  18. 42 CFR 423.150 - Scope.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... PROGRAM (CONTINUED) VOLUNTARY MEDICARE PRESCRIPTION DRUG BENEFIT Cost Control and Quality Improvement... utilization management programs, quality assurance measures and systems, and medication therapy management... organization (QIO) activities. (f) Compliance deemed on the basis of accreditation. (g) Accreditation...

  19. 42 CFR 423.150 - Scope.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... PROGRAM (CONTINUED) VOLUNTARY MEDICARE PRESCRIPTION DRUG BENEFIT Cost Control and Quality Improvement... utilization management programs, quality assurance measures and systems, and medication therapy management... organization (QIO) activities. (f) Compliance deemed on the basis of accreditation. (g) Accreditation...

  20. 42 CFR 423.150 - Scope.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... PROGRAM VOLUNTARY MEDICARE PRESCRIPTION DRUG BENEFIT Cost Control and Quality Improvement Requirements... utilization management programs, quality assurance measures and systems, and medication therapy management... organization (QIO) activities. (f) Compliance deemed on the basis of accreditation. (g) Accreditation...

  1. 42 CFR 423.150 - Scope.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... PROGRAM (CONTINUED) VOLUNTARY MEDICARE PRESCRIPTION DRUG BENEFIT Cost Control and Quality Improvement... utilization management programs, quality assurance measures and systems, and medication therapy management... organization (QIO) activities. (f) Compliance deemed on the basis of accreditation. (g) Accreditation...

  2. 46 CFR 56.60-2 - Limitations on materials.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... with a maximum design temperature of 150 °F. The material must not be used for salt water service or other fluids that may cause dezincification or stress corrosion cracking. 6 [Reserved] 7 An ammonia...

  3. 46 CFR 56.60-2 - Limitations on materials.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... with a maximum design temperature of 150 °F. The material must not be used for salt water service or other fluids that may cause dezincification or stress corrosion cracking. 6 [Reserved] 7 An ammonia...

  4. 46 CFR 56.60-2 - Limitations on materials.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... with a maximum design temperature of 150 °F. The material must not be used for salt water service or other fluids that may cause dezincification or stress corrosion cracking. 6 [Reserved] 7 An ammonia...

  5. 16 CFR 1632.5 - Mattress pad test procedure.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ....2.2 and 8.2.3 of AATCC Test Method 124-1996, using wash temperature V (60° ±3 °C, 140° ±5 °F... Laundering,” Tumble Dry, using the exhaust temperature (66° ±5 °C, 150° ±10 °F) and cool down time of 10... of their flame resistance. Such labels shall be permanent and otherwise in accordance with rules and...

  6. 16 CFR § 1632.5 - Mattress pad test procedure.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ....2.2 and 8.2.3 of AATCC Test Method 124-1996, using wash temperature V (60° ±3 °C, 140° ±5 °F... Laundering,” Tumble Dry, using the exhaust temperature (66° ±5 °C, 150° ±10 °F) and cool down time of 10... of their flame resistance. Such labels shall be permanent and otherwise in accordance with rules and...

  7. 16 CFR 1632.5 - Mattress pad test procedure.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ....2.2 and 8.2.3 of AATCC Test Method 124-1996, using wash temperature V (60° ±3 °C, 140° ±5 °F... Laundering,” Tumble Dry, using the exhaust temperature (66° ±5 °C, 150° ±10 °F) and cool down time of 10... of their flame resistance. Such labels shall be permanent and otherwise in accordance with rules and...

  8. 16 CFR 1632.5 - Mattress pad test procedure.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ....2.2 and 8.2.3 of AATCC Test Method 124-1996, using wash temperature V (60° ±3 °C, 140° ±5 °F... Laundering,” Tumble Dry, using the exhaust temperature (66° ±5 °C, 150° ±10 °F) and cool down time of 10... of their flame resistance. Such labels shall be permanent and otherwise in accordance with rules and...

  9. Diffusion welding. [heat treatment of nickel alloys following single step vacuum welding process

    NASA Technical Reports Server (NTRS)

    Holko, K. H. (Inventor)

    1974-01-01

    Dispersion-strengthened nickel alloys are sanded on one side and chemically polished. This is followed by a single-step welding process wherein the polished surfaces are forced into intimate contact at 1,400 F for one hour in a vacuum. Diffusion, recrystallization, and grain growth across the original weld interface are obtained during postheating at 2,150 F for two hours in hydrogen.

  10. One-step spray processing of high power all-solid-state supercapacitors

    PubMed Central

    Huang, Chun; Grant, Patrick S.

    2013-01-01

    Aqueous suspensions of multi-wall carbon nanotubes (MWNTs) in dilute H2SO4 were sprayed onto both sides of a Nafion membrane and dried to fabricate flexible solid-state supercapacitors. A single cell with MWNT-only electrodes had a capacitance of 57 F g−1 per electrode at 2 mV s−1 and 44 F g−1 at 150 mV s−1 but with low H+ mobility. Cells with MWNT + ionomer hybrid electrodes showed higher H+ mobility, and the electric double layer (EDL) capacitance increased to 145 F g−1 at 2 mV s−1 and 91 F g−1 at 150 mV s−1. The energy and power densities of one electrode charged to 1 V at 1 A g−1 were 12.9 Wh kg−1 and 3.3 kW kg−1 respectively. Three solid-state supercapacitor cells connected in series charged to 3 V at 1 and 2 A g−1 provided a device power density of 8.9 kW kg−1 at 1 A g−1 and 9.4 kW kg−1 at 2 A g−1, the highest for all-solid-state EDL supercapacitors. PMID:23928828

  11. High-temperature supercapacitor with a proton-conducting metal pyrophosphate electrolyte

    PubMed Central

    Hibino, Takashi; Kobayashi, Kazuyo; Nagao, Masahiro; Kawasaki, Shinji

    2015-01-01

    Expanding the range of supercapacitor operation to temperatures above 100°C is important because this would enable capacitors to operate under the severe conditions required for next-generation energy storage devices. In this study, we address this challenge by the fabrication of a solid-state supercapacitor with a proton-conducting Sn0.95Al0.05H0.05P2O7 (SAPO)-polytetrafluoroethylene (PTFE) composite electrolyte and a highly condensed H3PO4 electrode ionomer. At a temperature of 200°C, the SAPO-PTFE electrolyte exhibits a high proton conductivity of 0.02 S cm−1 and a wide withstanding voltage range of ±2 V. The H3PO4 ionomer also has good wettability with micropore-rich activated carbon, which realizes a capacitance of 210 F g−1 at 200°C. The resulting supercapacitor exhibits an energy density of 32 Wh kg−1 at 3 A g−1 and stable cyclability after 7000 cycles from room temperature to 150°C. PMID:25600936

  12. Resistive Wall Modes Identification and Control in RFX-mod low qedge tokamak discharges

    NASA Astrophysics Data System (ADS)

    Baruzzo, Matteo; Bolzonella, Tommaso; Cavazzana, Roberto; Marchiori, Giuseppe; Marrelli, Lionello; Martin, Piero; Paccagnella, Roberto; Piovesan, Paolo; Piron, Lidia; Soppelsa, Anton; Zanca, Paolo; in, Yongkyoon; Liu, Yueqiang; Okabayashi, Michio; Takechi, Manabu; Villone, Fabio

    2011-10-01

    In this work the MHD stability of RFX mode tokamak discharges with qedge < 3 will be studied. The target plasma scenario is characterized by a plasma current 100kA

  13. Changes in quantity and spectroscopic properties of water-extractable organic matter during soil aquifer treatment.

    PubMed

    Xue, S; Zhao, Q L; Wei, L L; Ma, X P; Tie, M

    2013-01-01

    The aim of this study was to identify qualitative and quantitative changes in the character of water-extractable organic matter (WEOM) in soils as a consequence of soil aquifer treatment (SAT). Soil samples were obtained from a soil-column system with a 2-year operation, and divided into seven layers from top to bottom: CS1 (0-12.5 cm), CS2 (12.5-25 cm), CS3 (25-50 cm), CS4 (50-75 cm), CS5 (75-100 cm), CS6 (100-125 cm) and CS7 (125-150 cm). A sample of the original soil used to pack the columns was also analysed to determine the effects of SAT. Following 2 years of SAT operation, both soil organic carbon and water-extractable organic carbon were shown to accumulate in the top soil layer (0-12.5 cm), and to decrease in soil layers deeper than 12.5 cm. The WEOM in the top soil layer was characterized by low aromaticity index (AI), low emission humification index (HIX) and low fluorescence efficiency index (F(eff)). On the other hand, the WEOM in soil layers deeper than 12.5 cm had increased values of HIX and F(eff), as well as decreased AI values relative to the original soil before SAT. In all soil layers, the percentage of hydrophobic and transphilic fractions decreased, while that of the hydrophilic fraction increased, as a result of SAT. The production of the amide-2 functional groups was observed in the top soil layer. SAT operation also led to the enrichment of hydrocarbon and amide-1 functional groups, as well as the depletion of oxygen-containing functional groups in soil layers deeper than 12.5 cm.

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boyd, P.W.; Gall, M.P.; Silver, M.W.

    A central question addressed by the VERTIGO (VERtical Transport In the Global Ocean) study was 'What controls the efficiency of particle export between the surface and subsurface ocean'? Here, we present data from sites at ALOHA (N Central Pacific Gyre) and K2 (NW subarctic Pacific) on phytoplankton processes, and relate them via a simple planktonic foodweb model, to subsurface particle export (150-500 m). Three key factors enable quantification of the surface-subsurface coupling: a sampling design to overcome the temporal lag and spatial displacement between surface and subsurface processes; data on the size-partitioning of Net Primary Production (NPP) and subsequent transformationsmore » prior to export; estimates of the ratio of algal- to faecal-mediated vertical export flux. At ALOHA, phytoplankton were characterized by low stocks, NPP, F{sub v}/F{sub m} (N-limited), and were dominated by picoplankton. The HNLC waters at K2 were characterized by both two-fold changes in NPP and floristic shifts (high to low proportion of diatoms) between deployment 1 and 2. Prediction of export exiting the euphotic zone was based on size-partitioning of NPP, a copepod-dominated foodweb and a ratio of 0.2 (ALOHA) and 0.1 (K2) for algal:faecal particle flux. Predicted export was 20-22 mg POC m{sup -2} d{sup -1} at ALOHA (i.e. 10-11% NPP (0-125 m); 1.1-1.2 x export flux at 150 m (E{sub 150}). At K2, export was 111 mg C m{sup -2} d{sup -1} (21% NPP (0-50 m); 1.8 x E{sub 150}) and 33 mg POC m{sup -2} d{sup -1} (11% NPP, 0-55 m); 1.4 x E{sub 150}) for deployments 1 and 2, respectively. This decrease in predicted export at K2 matches the observed trend for E{sub 150}. Also, the low attenuation of export flux from 60 to 150 m is consistent with that between 150 to 500 m. This strong surface-subsurface coupling suggests that phytoplankton productivity and floristics play a key role at K2 in setting export flux, and moreover that pelagic particle transformations by grazers strongly influence to what extent sinking particles are further broken down in the underlying waters of the Twilight Zone.« less

  15. 76 FR 69123 - Airworthiness Directives; Cessna Aircraft Company Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-08

    ..., and the attachment hardware with a new rudder stop modification kit for certain Cessna Models 150F... with the portion of the AD per compliance with 14 CFR 43.9. * * * * * Issued in Kansas City, Missouri...

  16. Inter-hemispheric asymmetry of Pedersen conductance

    NASA Astrophysics Data System (ADS)

    Deng, Y.; Lu, Y.; Sheng, C.; Yue, X.

    2015-12-01

    Ionospheric conductance is very important to the magnetosphere-ionosphere coupling in the high latitude region, since it connects the polar cap potential with the currents. Meanwhile, the altitudinal distribution of Pederson conductance gives us a rough idea about the altitudinal distribution of Joule heating at high latitudes. Based on the Constellation Observing System for Meteorology, Ionosphere, and Climate (COSMIC) satellites observations of electron density profiles from 2009-2014, Pedersen conductivity has been calculated. A climatologic study of the height-integrated Pedersen conductivities in both E (100-150 km) and F (150-600 km) regions and their ratio in different seasons, solar and geomagnetic conditions have been conducted. A significant inter-hemispheric asymmetry is identified in the seasonal variation. Meanwhile, the conductance in both regions and the conductance ratio show a strong dependence on F10.7 and Ap indices. This result will strongly help our understanding of the inter-hemispheric difference in the high-latitude electrodynamics.

  17. Geomagnetic Storm Effects at F1 Layer Altitudes in Various Periods of Solar Activity (Irkutsk Station)

    NASA Astrophysics Data System (ADS)

    Kushnarenko, G. P.; Yakovleva, O. E.; Kuznetsova, G. M.

    2018-03-01

    The influence of geomagnetic disturbances on electron density Ne at F1 layer altitudes in different conditions of solar activity during the autumnal and vernal seasons of 2003-2015, according to the data from the Irkutsk digital ionospheric station (52° N, 104° E) is examined. Variations of Ne at heights of 150-190 km during the periods of twenty medium-scale and strong geomagnetic storms have been analyzed. At these specified heights, a vernal-autumn asymmetry of geomagnetic storm effects is discovered in all periods of solar activity of 2003-2015: a considerable Ne decrease at a height of 190 km and a weaker effect at lower levels during the autumnal storms. During vernal storms, no significant Ne decrease as compared with quiet conditions was registered over the entire analyzed interval of 150-190 km.

  18. Flexural properties of structural lumber products after long-term exposure to high temperatures

    Treesearch

    Bruce A. Craig; David W. Green; David S. Gromala

    2006-01-01

    When wood fiber is exposed to significant heat, its strength decreases. It has long been known that prolonged heating at temperatures over 66°C (150°F) can cause a permanent loss in strength. The National Design Specification (NDS) provides factors (Ct) for adjusting allowable properties when structural wood members are exposed to temperatures between 38°C (100°F) and...

  19. 24 CFR 891.150 - Operating cost standards.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... through 891.790, the operating cost standard for group homes shall be based on the number of residents... as differences in costs based on location within the field office jurisdiction. The operating cost...

  20. Initial hazard assessment of 4-benzylphenol, a structural analog of bisphenol F: Genotoxicity tests in vitro and a 28-day repeated-dose toxicity study in rats.

    PubMed

    Igarashi, Toshime; Serizawa, Hideki; Kobayashi, Katsumi; Suzuki, Hiroshi; Matsumoto, Mariko; Iso, Takako; Kawamura, Tomoko; Inoue, Kaoru; Ono, Atsushi; Yamada, Takashi; Hirose, Akihiko

    2018-04-27

    4-Benzylphenol (CAS No. 101-53-1), a structural analog of bisphenol F, has estrogenic activity in vitro and in vivo, as is the case with bisphenol F. 4-Benzylphenol is used in plastics and during organic synthesis. Since its safety is largely unknown, we conducted toxicity tests as part of screening risk assessment in an existing chemical safety survey program. Based on results of the Ames test and the chromosomal aberration test using Chinese hamster lung cells (OECD TG 471 and 473), 4-benzylphenol was determined to be non-genotoxic in vitro. In a 28-day repeated-dose toxicity study, Crl:CD (SD) rats were administrated 4-benzylphenol by gavage at 0, 30, 150, or 750 mg/kg/day (OECD TG 407). Consequently, body weight was lower in males at 750 mg/kg/day. In the liver, relative organ weights were increased in both sexes at 750 mg/kg/day, and centrilobular hepatocellular hypertrophy was observed in males at 150 and 750 mg/kg/day. In the forestomach, hyperkeratosis and hyperplasia of squamous cells were observed in males at 150 and 750 mg/kg/day, and in females at 750 mg/kg/day. Based on these results, we identified the NOAEL for 4-benzylphenol as 30 mg/kg/day, with a hazard assessment value (D-value) of 0.05 mg/kg/day corresponding to hazard class 3. Copyright © 2018 Elsevier Inc. All rights reserved.

  1. 40 CFR 82.150 - Purpose and scope.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) PROTECTION OF STRATOSPHERIC OZONE Recycling and Emissions Reduction § 82.150 Purpose and scope. (a) The... to the lowest achievable level by maximizing the recapture and recycling of such refrigerants during..., appliance owners and operators, manufacturers of appliances, manufacturers of recycling and recovery...

  2. 40 CFR 82.150 - Purpose and scope.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) PROTECTION OF STRATOSPHERIC OZONE Recycling and Emissions Reduction § 82.150 Purpose and scope. (a) The... to the lowest achievable level by maximizing the recapture and recycling of such refrigerants during..., appliance owners and operators, manufacturers of appliances, manufacturers of recycling and recovery...

  3. 40 CFR 82.150 - Purpose and scope.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) PROTECTION OF STRATOSPHERIC OZONE Recycling and Emissions Reduction § 82.150 Purpose and scope. (a) The... to the lowest achievable level by maximizing the recapture and recycling of such refrigerants during..., appliance owners and operators, manufacturers of appliances, manufacturers of recycling and recovery...

  4. 40 CFR 82.150 - Purpose and scope.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) PROTECTION OF STRATOSPHERIC OZONE Recycling and Emissions Reduction § 82.150 Purpose and scope. (a) The... to the lowest achievable level by maximizing the recapture and recycling of such refrigerants during..., appliance owners and operators, manufacturers of appliances, manufacturers of recycling and recovery...

  5. 40 CFR 82.150 - Purpose and scope.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) PROTECTION OF STRATOSPHERIC OZONE Recycling and Emissions Reduction § 82.150 Purpose and scope. (a) The... to the lowest achievable level by maximizing the recapture and recycling of such refrigerants during..., appliance owners and operators, manufacturers of appliances, manufacturers of recycling and recovery...

  6. 33 CFR 150.602 - What occupational awareness training is required?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... safety and health, the implementation of an approved, port-specific safety and environmental management... HOMELAND SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Workplace Safety and Health Safety and Health (general) § 150.602 What occupational awareness training is required? (a) Each...

  7. Papers on Program Testing,

    DTIC Science & Technology

    1979-01-01

    tractability for scientific analysis. Although much remains to be learned about mutation as a testing tool, there is a considerable body of written material...explicitly address classifications (2) may not have been affected at all! In general, the and (3) in this article , except to point out that even relative...34 ARTICLE B=B’B C IN CACM 1971). C=C*02 INTEGER AiN),N.F D=B+C INTEGER M.NS.R.I.J.W IF (A.NE.D) GOTO 200 MI PRINT 150 NS=N 150 FORMATIIH .RIGHT ANGLED

  8. 49 CFR 192.123 - Design limitations for plastic pipe.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... formula under § 192.121 is determined. (ii) For reinforced thermosetting plastic pipe, 150 °F (66 °C). (c...) The wall thickness for reinforced thermosetting plastic pipe may not be less than that listed in the...

  9. 16 CFR 1630.1 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ...) Traffic Surface means a surface of a carpet or rug which is intended to be walked upon. (f) Timed Burning.../gram, a mass of 150 mg ±5mg and a nominal diameter of 6mm. (g) Fire-Retardant Treatment means any...

  10. 7 CFR 457.150 - Dry bean crop insurance provisions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... established grass or legume. (b) For contract seed beans only: (1) An instrument in the form of a “lease...; (f) Earthquake; (g) Volcanic eruption; or (h) Failure of the irrigation water supply, if caused by an...

  11. EFFECTS OF LASER RADIATION ON MATTER. LASER PLASMA Annealing of induced absorption in quartz glasses by ArF laser radiation

    NASA Astrophysics Data System (ADS)

    Sergeev, P. B.; Sergeev, A. P.

    2010-11-01

    Annealing of individual bands of electron-beam-induced absorption (IA) in the region of 150 — 400 nm in KS-4V, KU-1, and Corning 7980 (ArF Grade) quartz glasses by ArF laser radiation is studied. It is shown that the phototransformation of the IA spectra occurs mainly due to a significant decrease in the amplitudes of bands at λ = 183.5, 213, and 260 nm. The role played by interstitial oxygen, hydrogen, and chlorine in the formation and relaxation of glass defects is considered.

  12. Waveguide Power-Amplifier Module for 80 to 150 GHz

    NASA Technical Reports Server (NTRS)

    Samoska, Lorene; Weinreb, Sander; Peralta, Alejandro

    2006-01-01

    A waveguide power-amplifier module capable of operating over the frequency range from 80 to 150 GHz has been constructed. The module comprises a previously reported power amplifier packaged in a waveguide housing that is compatible with WR-8 waveguides. (WR- 8 is a standard waveguide size for the nominal frequency range from 90 to 140 GHz.) The waveguide power-amplifier module is robust and can be bolted to test equipment and to other electronic circuits with which the amplifier must be connected for normal operation.

  13. Influence of Orientia tsutsugamushi infection on the developmental biology of Leptotrombidium imphalum and Leptotrombidium chiangraiensis (Acari: Trombiculidae).

    PubMed

    Phasomkusolsil, Siriporn; Tanskul, Panita; Ratanatham, Supaporn; Watcharapichat, Pochaman; Phulsuksombati, Duangporn; Frances, Stephen P; Lerdthusnee, Kriangkrai; Linthicum, Kenneth J

    2012-11-01

    Leptotrombidium chiangraiensis Tanskul & Linthicum, and Leptotrombidium imphalum Vercammen-Grandjean are important vectors of scrub typhus in rice field habitats in northern Thailand. The developmental biology of all stages of the life cycle of two generations of these species of mites infected with Orientia tsutsugamushi (Hayashi) and uninfected mites is reported. The development of the infected lines of both F1 and F2 L. chiangraiensis were significantly longer than their respective uninfected lines (P < 0.05). The developmental times of uninfected and infected F1 lines of L. imphalum were not significantly different; however, F2 infected lines took significantly longer to develop (P < 0.05). Both F1 and F2 generations of infected L. imphalum and L. chiangraiensis oviposited on average >150 fewer eggs than uninfected mites.

  14. 33 CFR 150.620 - What are the requirements for protecting personnel from machinery?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... deepwater port operator must ensure that all personnel are protected from the risks created by operating..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Workplace Safety and...

  15. 76 FR 31459 - Airworthiness Directives; BAE SYSTEMS (OPERATIONS) LIMITED Model BAe 146 and Avro 146-RJ Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-01

    ... crack was present at the time of the embodiment of M-D SB 146-32-150, Part B or Part C, it could... inspections, by embodiment of Messier-Dowty (M-D) Service Bulletin (SB) SB.146-32-150. Later, as part of an... optional closing action of EASA AD 2010-0001-E is embodiment of M-D SB 146-32-150 (polishing and shot...

  16. 36 CFR 1154.150 - Program accessibility: Existing facilities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... TRANSPORTATION BARRIERS COMPLIANCE BOARD ENFORCEMENT OF NONDISCRIMINATION ON THE BASIS OF HANDICAP IN PROGRAMS OR ACTIVITIES CONDUCTED BY THE ARCHITECTURAL AND TRANSPORTATION BARRIERS COMPLIANCE BOARD § 1154.150 Program accessibility: Existing facilities. (a) General. The agency shall operate each program or activity so that the...

  17. 47 CFR 95.1211 - Channel use policy.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... in the 400.150-406.000 MHz band in the Meteorological Aids, Meteorological Satellite, or Earth... in the 400.150-406.000 MHz band in the Meteorological Aids, Meteorological Satellite, or Earth..., Meteorological Satellite, or Earth Exploration Satellite Services, or to other authorized stations operating in...

  18. Experimental Investigations of Boron, Lithium, and Halogens During High-Temperature Water-Rock Interaction: Insights into the Yellowstone Hydrothermal System

    NASA Astrophysics Data System (ADS)

    Cullen, J. T.; Hurwitz, S.; Thordsen, J. J.; Barnes, J.

    2017-12-01

    B, Li, and halogens (Cl, F, Br) are used extensively in studies of thermal waters to infer fluid equilibrium conditions with the host reservoir lithology, and quantify the possible fraction of a magmatic component in thermal waters. Apart from fluorine, the limited number of minerals that incorporate these elements support the notion that they preferentially partition into an aqueous fluid during high temperature water-rock interaction. Although limited experimental work is largely consistent with these observations, a rigorous experimental investigation is required to quantify the mobility of these elements under conditions emulating a silicic hydrothermal system. Here we present the results from water-rhyolite interaction batch experiments conducted over a range of temperatures between 150 °C and 350 °C and 250 bar. Powdered obsidian from Yellowstone was reacted with MiliQ water and sampled intermittently throughout the duration of the 90 day experiment. The experimental data show that at temperatures ≤ 200 °C, B, Cl, Br, and Li are not readily leached from the rhyolite, whereas aqueous F- concentration increases by a factor of 3.5 when the temperature was increased from 150 °C to 200 °C. Between 200 °C and 250 °C, B concentration increased by more than an order of magnitude and Cl- concentration increased by a factor of 5. F- concentration increased by a factor of 3. Between 250 °C and 300 °C the opposite trend was observed, in which F- concentration decreased by 60%, Br- concentration increased by a factor of 5, and Cl- and B concentrations increased by more than an order of magnitude. The progressive decrease of aqueous F- at T ≥ 300 °C is likely controlled by precipitation into a fluorine bearing secondary mineral(s). Our experimental results demonstrate that leaching of B, Li, Cl, F, and Br from rhyolite is highly temperature-dependent between 150 °C and 350 °C. These results can provide context to infer the sources of solutes discharged at thermal springs and the subsurface water-rhyolite equilibrium temperatures in the Yellowstone hydrothermal system. Work to characterize the alteration mineralogy and the temperature-dependent stable Cl, Li, and B isotope fractionation is currently ongoing. Keywords: Yellowstone, hydrothermal, halogens, experiments, water-rock interaction

  19. Experimental Investigations of Boron, Lithium, and Halogens During High-Temperature Water-Rock Interaction: Insights into the Yellowstone Hydrothermal System

    NASA Astrophysics Data System (ADS)

    Cullen, J. T.; Hurwitz, S.; Thordsen, J. J.; Barnes, J.

    2016-12-01

    B, Li, and halogens (Cl, F, Br) are used extensively in studies of thermal waters to infer fluid equilibrium conditions with the host reservoir lithology, and quantify the possible fraction of a magmatic component in thermal waters. Apart from fluorine, the limited number of minerals that incorporate these elements support the notion that they preferentially partition into an aqueous fluid during high temperature water-rock interaction. Although limited experimental work is largely consistent with these observations, a rigorous experimental investigation is required to quantify the mobility of these elements under conditions emulating a silicic hydrothermal system. Here we present the results from water-rhyolite interaction batch experiments conducted over a range of temperatures between 150 °C and 350 °C and 250 bar. Powdered obsidian from Yellowstone was reacted with MiliQ water and sampled intermittently throughout the duration of the 90 day experiment. The experimental data show that at temperatures ≤ 200 °C, B, Cl, Br, and Li are not readily leached from the rhyolite, whereas aqueous F- concentration increases by a factor of 3.5 when the temperature was increased from 150 °C to 200 °C. Between 200 °C and 250 °C, B concentration increased by more than an order of magnitude and Cl- concentration increased by a factor of 5. F- concentration increased by a factor of 3. Between 250 °C and 300 °C the opposite trend was observed, in which F- concentration decreased by 60%, Br- concentration increased by a factor of 5, and Cl- and B concentrations increased by more than an order of magnitude. The progressive decrease of aqueous F- at T ≥ 300 °C is likely controlled by precipitation into a fluorine bearing secondary mineral(s). Our experimental results demonstrate that leaching of B, Li, Cl, F, and Br from rhyolite is highly temperature-dependent between 150 °C and 350 °C. These results can provide context to infer the sources of solutes discharged at thermal springs and the subsurface water-rhyolite equilibrium temperatures in the Yellowstone hydrothermal system. Work to characterize the alteration mineralogy and the temperature-dependent stable Cl, Li, and B isotope fractionation is currently ongoing. Keywords: Yellowstone, hydrothermal, halogens, experiments, water-rock interaction

  20. Ultralow field NMR spectrometer with an atomic magnetometer near room temperature

    NASA Astrophysics Data System (ADS)

    Liu, Guobin; Li, Xiaofeng; Sun, Xianping; Feng, Jiwen; Ye, Chaohui; Zhou, Xin

    2013-12-01

    We present a Cs atomic magnetometer with a sensitivity of 150 fT/Hz1/2 operating near room temperature. The nuclear magnetic resonance (NMR) signal of 125 μL tap water was detected at an ultralow magnetic field down to 47 nT, with the signal-to-noise ratio (SNR) of the NMR signal approaching 50 after eight averages. Relaxivity experiments with a Gd(DTPA) contrast agent in zero field were performed, in order to show the magnetometer's ability to measure spin-lattice relaxation time with high accuracy. This demonstrates the feasibility of an ultralow field NMR spectrometer based on a Cs atomic magnetometer, which has a low working temperature, short data acquisition time and high sensitivity. This kind of NMR spectrometer has great potential in applications such as chemical analysis and magnetic relaxometry detection in ultralow or zero fields.

  1. Ignition characterization of the GOX/ethanol propellant combination

    NASA Technical Reports Server (NTRS)

    Lawver, B. R.; Rousar, D. C.; Boyd, W. C.

    1984-01-01

    This paper describes the results of a study to define the ignition characteristics and thruster pulse mode capabilities of the GOX/ethanol propellant combination. Ignition limits were defined in terms of mixture ratio and cold flow pressure using a spark initiated torch igniter. Igniter tests were run over a wide range of cold flow pressure, propellant temperature and mixture ratio. The product of cold flow pressure and igniter chamber diameter was used to correlate mixture ratio regimes of ignition and nonignition. Engine ignition reliability and pulse mode capability were demonstrated using a 620 lbF thruster with an integrated torch igniter. The nominal chamber pressure and mixture ratio were 150 psia and 1.8, respectively, thruster tests were run over a wide range of chamber pressures and mixture ratios. The feasibility of thruster pulse mode operation with the non-hypergolic GOX/ethanol propellant combination was demonstrated.

  2. A microfabricated optically-pumped magnetic gradiometer

    NASA Astrophysics Data System (ADS)

    Sheng, D.; Perry, A. R.; Krzyzewski, S. P.; Geller, S.; Kitching, J.; Knappe, S.

    2017-01-01

    We report on the development of a microfabricated atomic magnetic gradiometer based on optical spectroscopy of alkali atoms in the vapor phase. The gradiometer, which operates in the spin-exchange relaxation free regime, has a length of 60 mm and cross sectional diameter of 12 mm, and consists of two chip-scale atomic magnetometers which are interrogated by a common laser light. The sensor can measure differences in magnetic fields, over a 20 mm baseline, of 10 fT/ Hz1 /2 at frequencies above 20 Hz. The maximum rejection of magnetic field noise is 1000 at 10 Hz. By use of a set of compensation coils wrapped around the sensor, we also measure the sensor sensitivity at several external bias field strengths up to 150 mG. This device is useful for applications that require both sensitive gradient field information and high common-mode noise cancellation.

  3. High-temperature test facility at the NASA Lewis engine components research laboratory

    NASA Technical Reports Server (NTRS)

    Colantonio, Renato O.

    1990-01-01

    The high temperature test facility (HTTF) at NASA-Lewis Engine Components Research Laboratory (ECRL) is presently used to evaluate the survivability of aerospace materials and the effectiveness of new sensing instrumentation in a realistic afterburner environment. The HTTF has also been used for advanced heat transfer studies on aerospace components. The research rig uses pressurized air which is heated with two combustors to simulate high temperature flow conditions for test specimens. Maximum airflow is 31 pps. The HTTF is pressure rated for up to 150 psig. Combustors are used to regulate test specimen temperatures up to 2500 F. Generic test sections are available to house test plates and advanced instrumentation. Customized test sections can be fabricated for programs requiring specialized features and functions. The high temperature test facility provides government and industry with a facility for testing aerospace components. Its operation and capabilities are described.

  4. Flavobacterium panacis sp. nov., isolated from rhizosphere of Panax ginseng.

    PubMed

    Kim, Dong Hyun; Singh, Priyanka; Farh, Mohamed El-Agamy; Kim, Yeon-Ju; Nguyen, Ngoc-Lan; Lee, Hyun A; Yang, Deok-Chun

    2016-09-01

    A novel bacterial strain, designated DCY106(T), was isolated from soil collected from the rhizosphere of ginseng (Panax ginseng), in Gochang, Republic of Korea. Strain DCY106(T) is Gram-negative, yellow-pigmented, non-flagellate, motile, non-spore-forming, rod-shaped, and strictly aerobic. The strain grows optimally at 25-30 °C and pH 6.5-7.5. Phylogenetically, strain DCY106(T) is closely related to Flavobacterium arsenitoxidans KCTC 22507(T) (98.41 %), followed by Flavobacterium cutihirudini LMG 26922(T) (97.67 %), Flavobacterium nitrogenifigens LMG 28694(T) (97.59 %), Flexibacter auranticus LMG 3987(T) (97.38 %), Flavobacterium defluvi KCTC 12612(T) (97.21 %) and Flavobacterium chilense LMG 26360(T) (97.05 %). The 16S rRNA gene sequence similarities to all other Flavobacterium species were below 97 %. The DNA G+C content of strain DCY106(T) is 34.2 mol% and the DNA-DNA relatedness between strain DCY106(T) and F. cutihirudini LMG 26922(T), F. auranticus LMG 3987(T), F. defluvi KCTC 12612(T) and F. chilense LMG 26360(T) were below 40.0 %. The menaquinone of the type MK-6 was found to be the predominant respiratory quinone. The major polar lipids were identified as phosphatidylethanolamine, phosphatidylserine, two unidentified aminolipids (APL1, APL6) and one unidentified lipid L2. C15:0, iso-C15:0 and summed feature 3 (iso-C15:0 2OH/C16:1 ω7c) were identified as the major fatty acids present in DCY106(T). The results of physiological and biochemical tests allowed strain DCY106(T) to be differentiated phenotypically from other recognized species belonging to the genus Flavobacterium. Therefore, it is suggested that the newly isolated organism represents a novel species, for which the name Flavobacterium panacis sp. nov. is proposed with the type strain designated as DCY106(T) (= JCM 31468(T)= KCTC 42747(T)).

  5. The effect of fluoride treatment on titanium treated with anodic spark oxidation

    NASA Astrophysics Data System (ADS)

    Park, Il Song; Kim, Jong Jun; Ahn, Seung Geun; Lee, Min Ho; Seol, Kyeong Won; Bae, Tae Sung

    2007-04-01

    This study examined the effect of fluoride on the surface characteristics of an anodized titanium implant. Commercial pure titanium plate 20mm×10mm×2mm in size, and discs 1.5 mm thick and 1.5 mm in diameter, were used. The prepared samples were polished with #200 to #1, 000 SiC papers and were then washed sequentially with distilled water, alcohol and acetone. Anodic oxidation was performed using a regulated DC power supply in an electrolyte containing a mixture of 0.015 M DL-α-glycerophosphate disodium salt hydrate (DL-α-GP) and 0.2 M calcium acetate hydrate (CA) with an electric current density of 30mA/cm2 and voltage ranging from 0 to 290 V. The specimens were divided into four groups and a fluoride treatment was carried out. Group 1 was thermally treated in a 0.05 M TiF3 solution at 90°C, Group 2 was electrochemically treated at 150 V in a 0.05 M TiF3 solution, Group 3 was electrochemically treated at 150 V in a 0.05 M NaF solution, and Group 4 was electrochemically treated at 150 V in a 0.05 M HF solution. A porous oxide layer containing pores 1-4 μm in size was observed on the surface treated with anodic oxidation. The diameter of the pores was higher in the protrusion areas than in the sunken areas. A significant amount of fluoride ions was released in the initial period, with small amounts being released continuously thereafter. The viability of MC3T3 cells was high when the fluoride ion concentration was 10 ppm, but decreased with further increases in the fluoride concentration. A six-week immersion test in simulated body fluid (SBF) showed dense HA crystals in the group immersed in 0.05 M TiF3 at 90°C, which indicated good biocompatibility.

  6. Molecular Basis of the Behavior of Hepatitis A Virus Exposed to High Hydrostatic Pressure

    PubMed Central

    D'Andrea, Lucía; Pérez-Rodríguez, Francisco J.; Costafreda, M. Isabel; Beguiristain, Nerea; Fuentes, Cristina; Aymerich, Teresa; Guix, Susana; Bosch, Albert

    2014-01-01

    Food-borne hepatitis A outbreaks may be prevented by subjecting foods at risk of virus contamination to moderate treatments of high hydrostatic pressure (HHP). A pretreatment promoting hepatitis A virus (HAV) capsid-folding changes enhances the virucidal effect of HHP, indicating that its efficacy depends on capsid conformation. HAV populations enriched in immature capsids (125S provirions) are more resistant to HHP, suggesting that mature capsids (150S virions) are more susceptible to this treatment. In addition, the monoclonal antibody (MAb) K24F2 epitope contained in the immunodominant site is a key factor for the resistance to HHP. Changes in capsid folding inducing a loss of recognition by MAb K24F2 render more susceptible conformations independently of the origin of such changes. Accordingly, codon usage-associated folding changes and changes stimulated by pH-dependent breathings, provided they confer a loss of recognition by MAb K24F2, induce a higher susceptibility to HHP. In conclusion, the resistance of HAV to HHP treatments may be explained by a low proportion of 150S particles combined with a good accessibility of the epitope contained in the immunodominant site close to the 5-fold axis. PMID:25107980

  7. Augmentor performance of an F100 engine model derivative engine in an F-15 airplane

    NASA Technical Reports Server (NTRS)

    Walton, James T.; Burcham, Frank W., Jr.

    1986-01-01

    The transient performance of the F100 engine model derivative (EMD) augmentor was evaluated in an F-15 airplane. The augmentor was a newly designed 16-segment augmentor. It was tested with a segment-1 sprayring with 90 deg fuel injection, and later with a modified segment-1 sprayring with centerline fuel injection. With the 90 deg injection, no-lights occurred at high altitudes with airspeeds of 175 knots or less; however, the results were better than when using the standard F100-PW-100 engine. With the centerline fuel injection, all transients were successful to an altitude of 15,500 meters and an airspeed of 150 knots: no failures to light, blowouts, or stalls occurred. For a first flight evaluation, the augmentor transient performance was excellent.

  8. Cadmium (Tank) Electroplating Alternative

    DTIC Science & Technology

    2011-08-01

    ASTM F519 HE: 75% NFS 200 hrs HRE : 45% NFS 150 hrs Threshold limit greater than /equal to LHE Cd (AMS 2417G) ASETS Defense Focused Workshop (2011...Test Specimens  Reporting Sustained/Threshold load (%NFS), Time to failure. HRE Testing Cd Zn-Ni IVD Al LHE Cd Re-Embrittlement Test Fluids:  DI...Hydrogen Embrittlement/ HRE ASTM F519 A5, Type 1.a.1 Brush Plating ASETS Defense Focused Workshop (2011) Luzmarie G. Santiago Materials Engineer Naval Air

  9. A Location Analysis Approach for Military Maintenance Scheduling with Geographically Dispersed Service Areas

    DTIC Science & Technology

    2009-01-01

    activities within the patrol area. Maintenance of the Minuteman III weapon system requires maintenance and security teams travel to one or more of 150...launch facilities, all of which are geograph- ically isolated from major population centers. Travel time from F. E. Warren AFB, the main support base...the F. E. Warren AFB work center to make travel preparations, and ends after all maintenance actions are completed, or once the team arrives at one

  10. Knock-limited performance of several internal coolants

    NASA Technical Reports Server (NTRS)

    Bellman, Donald R; Evvard, John C

    1945-01-01

    The effect of internal cooling on the knock-limited performance of an-f-28 fuel was investigated in a CFR engine, and the following internal coolants were used: (1) water, (2), methyl alcohol-water mixture, (3) ammonia-methyl alcohol-water mixture, (4) monomethylamine-water mixture, (5) dimethylamine-water mixture, and (6) trimethylamine-water mixture. Tests were run at inlet-air temperatures of 150 degrees and 250 degrees F. to indicate the temperature sensitivity of the internal-coolant solutions.

  11. 29 CFR 4907.150 - Program accessibility: Existing facilities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... IN PROGRAMS OR ACTIVITIES CONDUCTED BY THE PENSION BENEFIT GUARANTY CORPORATION § 4907.150 Program accessibility: Existing facilities. (a) General. The agency shall operate each program or activity so that the program or activity, when viewed in its entirety, is readily accessible to and usable by handicapped...

  12. 36 CFR 1208.150 - Program accessibility: Existing facilities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... OR ACTIVITIES CONDUCTED BY THE NATIONAL ARCHIVES AND RECORDS ADMINISTRATION § 1208.150 Program accessibility: Existing facilities. (a) General. The agency shall operate each program or activity so that the program or activity, when viewed in its entirety, is readily accessible to and usable by individuals with...

  13. 45 CFR 2490.150 - Program accessibility: Existing facilities.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... ACTIVITIES CONDUCTED BY THE JAMES MADISON MEMORIAL FELLOWSHIP FOUNDATION § 2490.150 Program accessibility: Existing facilities. (a) General. The agency shall operate each program or activity so that the program or activity, when viewed in its entirety, is readily accessible to and usable by individuals with handicaps...

  14. 45 CFR 150.313 - Market conduct examinations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Non-Federal Governmental Plans-Civil Money Penalties § 150.313 Market conduct examinations. (a..., or the operation of a non-Federal governmental plan, involving the review of one or more (or a... consist of one of the following: (i) Concurrence with the issuer's or non-Federal governmental plan's...

  15. 45 CFR 150.313 - Market conduct examinations.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Non-Federal Governmental Plans-Civil Money Penalties § 150.313 Market conduct examinations. (a..., or the operation of a non-Federal governmental plan, involving the review of one or more (or a... consist of one of the following: (i) Concurrence with the issuer's or non-Federal governmental plan's...

  16. 32 CFR 1699.150 - Program accessibility: existing facilities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... SYSTEM ENFORCEMENT OF NONDISCRIMINATION ON THE BASIS OF HANDICAP IN PROGRAMS OR ACTIVITIES CONDUCTED BY SELECTIVE SERVICE SYSTEM § 1699.150 Program accessibility: existing facilities. (a) General. The agency shall operate each program or activity so that the program or activity, when viewed in its entirety, is...

  17. Nabiximols as an agonist replacement therapy during cannabis withdrawal: a randomized clinical trial.

    PubMed

    Allsop, David J; Copeland, Jan; Lintzeris, Nicholas; Dunlop, Adrian J; Montebello, Mark; Sadler, Craig; Rivas, Gonzalo R; Holland, Rohan M; Muhleisen, Peter; Norberg, Melissa M; Booth, Jessica; McGregor, Iain S

    2014-03-01

    There are no medications approved for treating cannabis dependence or withdrawal. The cannabis extract nabiximols (Sativex), developed as a multiple sclerosis treatment, offers a potential agonist medication for cannabis withdrawal. To evaluate the safety and efficacy of nabiximols in treating cannabis withdrawal. A 2-site, double-blind randomized clinical inpatient trial with a 28-day follow-up was conducted in New South Wales, Australia. Participants included 51 DSM-IV-TR cannabis-dependent treatment seekers. A 6-day regimen of nabiximols (maximum daily dose, 86.4 mg of Δ9-tetrahydrocannabinol and 80 mg of cannabidiol) or placebo with standardized psychosocial interventions during a 9-day admission. Severity of cannabis withdrawal and cravings (Cannabis Withdrawal Scale), retention in withdrawal treatment, and adverse events. Secondary outcomes include postwithdrawal cannabis use, health outcomes, and psychosocial outcomes. Nabiximols treatment significantly reduced the overall severity of cannabis withdrawal relative to placebo (F8,377.97 = 2.39; P = .01), including effects on withdrawal-related irritability, depression, and cannabis cravings. Nabiximols had a more limited, but still positive, therapeutic benefit on sleep disturbance, anxiety, appetite loss, physical symptoms, and restlessness. Nabiximols patients remained in treatment longer during medication use (unadjusted hazard ratio, 3.66 [95% CI, 1.18-11.37]; P = .02), with 2.84 the number needed to treat to achieve successful retention in treatment. Participants could not reliably differentiate between nabiximols and placebo treatment (χ21 = 0.79; P = .67), and those receiving nabiximols did not report greater intoxication (F1,6 = 0.22; P = .97). The number (F1,50 = 0.3; P = .59) and severity (F1,50 = 2.69; P = .10) of adverse events did not differ significantly between groups. Both groups showed reduced cannabis use at follow-up, with no advantage of nabiximols over placebo for self-reported cannabis use (F1,48 = 0.29; P = .75), cannabis-related problems (F1,49 = 2.33; P = .14), or cannabis dependence (F1,50 < 0.01; P = .89). In a treatment-seeking cohort, nabiximols attenuated cannabis withdrawal symptoms and improved patient retention in treatment. However, placebo was as effective as nabiximols in promoting long-term reductions in cannabis use following medication cessation. The data support further evaluation of nabiximols for management of cannabis dependence and withdrawal in treatment-seeking populations. anzctr.org.au Identifier: ACTRN12611000398909.

  18. Femtosecond Visible Transient Absorption Spectroscopy of Chlorophyll f-Containing Photosystem I.

    PubMed

    Kaucikas, Marius; Nürnberg, Dennis; Dorlhiac, Gabriel; Rutherford, A William; van Thor, Jasper J

    2017-01-24

    Photosystem I (PSI) from Chroococcidiopsis thermalis PCC 7203 grown under far-red light (FRL; >725 nm) contains both chlorophyll a and a small proportion of chlorophyll f. Here, we investigated excitation energy transfer and charge separation using this FRL-grown form of PSI (FRL-PSI). We compared femtosecond transient visible absorption changes of normal, white-light (WL)-grown PSI (WL-PSI) with those of FRL-PSI using excitation at 670 nm, 700 nm, and (in the case of FRL-PSI) 740 nm. The possibility that chlorophyll f participates in energy transfer or charge separation is discussed on the basis of spectral assignments. With selective pumping of chlorophyll f at 740 nm, we observe a final ∼150 ps decay assigned to trapping by charge separation, and the amplitude of the resulting P700 +• A 1 -• charge-separated state indicates that the yield is directly comparable to that of WL-PSI. The kinetics shows a rapid 2 ps time constant for almost complete transfer to chlorophyll f if chlorophyll a is pumped with a wavelength of 670 nm or 700 nm. Although the physical role of chlorophyll f is best supported as a low-energy radiative trap, the physical location should be close to or potentially within the charge-separating pigments to allow efficient transfer for charge separation on the 150 ps timescale. Target models can be developed that include a branching in the formation of the charge separation for either WL-PSI or FRL-PSI. Copyright © 2017 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  19. Analysis of mutational resistance to trimethoprim in Staphylococcus aureus by genetic and structural modelling techniques.

    PubMed

    Vickers, Anna A; Potter, Nicola J; Fishwick, Colin W G; Chopra, Ian; O'Neill, Alex J

    2009-06-01

    This study sought to expand knowledge on the molecular mechanisms of mutational resistance to trimethoprim in Staphylococcus aureus, and the fitness costs associated with resistance. Spontaneous trimethoprim-resistant mutants of S. aureus SH1000 were recovered in vitro, resistance genotypes characterized by DNA sequencing of the gene encoding the drug target (dfrA) and the fitness of mutants determined by pair-wise growth competition assays with SH1000. Novel resistance genotypes were confirmed by ectopic expression of dfrA alleles in a trimethoprim-sensitive S. aureus strain. Molecular models of S. aureus dihydrofolate reductase (DHFR) were constructed to explore the structural basis of trimethoprim resistance, and to rationalize the observed in vitro fitness of trimethoprim-resistant mutants. In addition to known amino acid substitutions in DHFR mediating trimethoprim resistance (F(99)Y and H(150)R), two novel resistance polymorphisms (L(41)F and F(99)S) were identified among the trimethoprim-resistant mutants selected in vitro. Molecular modelling of mutated DHFR enzymes provided insight into the structural basis of trimethoprim resistance. Calculated binding energies of the substrate (dihydrofolate) for the mutant and wild-type enzymes were similar, consistent with apparent lack of fitness costs for the resistance mutations in vitro. Reduced susceptibility to trimethoprim of DHFR enzymes carrying substitutions L(41)F, F(99)S, F(99)Y and H(150)R appears to result from structural changes that reduce trimethoprim binding to the enzyme. However, the mutations conferring trimethoprim resistance are not associated with fitness costs in vitro, suggesting that the survival of trimethoprim-resistant strains emerging in the clinic may not be subject to a fitness disadvantage.

  20. The Solar Flux Dependence of Ionospheric 150 km Radar Echoes and Implications

    NASA Astrophysics Data System (ADS)

    Patra, A. K.; Pavan Chaitanya, P.; St.-Maurice, J.-P.; Otsuka, Y.; Yokoyama, T.; Yamamoto, M.

    2017-11-01

    Radar echoes from the daytime equatorial ionospheric F1 region, popularly known as "150 km echoes," have challenged ionospheric plasma physicists for several decades. Recent theoretical simulations showed that enhanced photoelectron fluxes can amplify the amplitude of plasma waves, generating spectra similar to those of the radar echoes, implying that larger solar fluxes should produce more frequent and stronger 150 km echoes. Inspired by this proposal, we studied the occurrence and intensity dependence of the echoes on the EUV flux observed by SOHO over several years. The occurrence and intensity of the echoes were found to have an inverse relationship with this EUV flux measurement. The multiyear trend is independent of the variability often observed over successive days with nearly identical EUV fluxes. These results imply that the relationship between the echoes and EUV flux is more complex. We propose that gravity waves modulate the amplitude of 150 km echoes through changes in the variations in plasma density and photoelectron fluxes associated with the gravity wave-induced neutral density modulations.

  1. NmF2 Morphology during four-classes of solar and magnetic activity conditions at an African station around the EIA trough and comparison with IRI-2016 Map

    NASA Astrophysics Data System (ADS)

    Adebesin, B.; Rabiu, B.; Obrou, O. K.

    2017-12-01

    Better understanding of the electrodynamics between parameters used in describing the ionospheric layer and their solar and geomagnetic influences goes a long way in furthering the expansion of space weather knowledge. Telecommunication and scientific radar launch activities can however be interrupted either on a larger/smaller scales by geomagnetic activities which is susceptible to changes in solar activity and effects. Consequently, the ionospheric NmF2 electrodynamics was investigated for a station near the magnetic dip in the African sector (Korhogo, Geomagnetic: -1.26°N, 67.38°E). Data covering years 1996 and 2000 were investigated for four categories of magnetic and solar activities viz (i) F10.7 < 85 sfu, ap ≤ 7 nT (low solar quiet, LSQ); (ii) F10.7 < 85 sfu, ap > 7 nT (low solar disturbed, LSD); (iii) F10.7 > 150 sfu, ap ≤ 7 nT (high solar quiet, HSQ); and (iv) F10.7 > 150 sfu, ap > 7 nT (high solar disturbed, HSD). NmF2 revealed a pre-noon peak higher than the post-noon peak during high solar activity irrespective of magnetic activity condition and overturned during low solar activity. Higher NmF2 peak amplitude however characterise disturbed magnetic activity than quiet magnetic condition for any solar activity. The maximum pre-/post-noon peaks appeared in equinox season. June solstice noon-time bite out lagged other seasons by 1-2 h. Daytime variability increases with increasing magnetic activity. Equinox/June solstice recorded the highest pre-sunrise/post-sunset peak variability magnitudes with the lowest emerging in June solstice/equinox for all solar and magnetic conditions. The nighttime annual variability amplitude is higher during disturbed than quiet condition regardless of solar activity period; while the range is similar for daytime observations. The noon-time trough characteristics is not significant in the IRI NmF2 pattern during high solar activity but evident during low solar conditions. IRI-2016 map performed best during disturbed activity conditions especially for F10.7 < 85 sfu, ap > 7 nT condition.

  2. 27 CFR 44.150 - Special.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... PAYMENT OF TAX, OR WITH DRAWBACK OF TAX Operations by Export Warehouse Proprietors Reports § 44.150... inventory required by an appropriate TTB officer, shall be made with such inventory. Another report, covering the period from the date of such inventory to the end of the month, shall be made on or before the...

  3. 22 CFR 1005.150 - Program accessibility: Existing facilities.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... THE BASIS OF HANDICAP IN PROGRAMS OR ACTIVITIES CONDUCTED BY THE INTER-AMERICAN FOUNDATION § 1005.150 Program accessibility: Existing facilities. (a) General. The agency shall operate each program or activity so that the program or activity, when viewed in its entirety, is readily accessible to and usable by...

  4. 12 CFR 794.150 - Program accessibility: Existing facilities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... HANDICAP IN PROGRAMS OR ACTIVITIES CONDUCTED BY THE NATIONAL CREDIT UNION ADMINISTRATION § 794.150 Program accessibility: Existing facilities. (a) General. The agency shall operate each program or activity so that the program or activity, when viewed in its entirety, is readily accessible to and usable by handicapped...

  5. 50 CFR 550.150 - Program accessibility: Existing facilities.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... NONDISCRIMINATION ON THE BASIS OF HANDICAP IN PROGRAMS OR ACTIVITIES CONDUCTED BY MARINE MAMMAL COMMISSION § 550.150 Program accessibility: Existing facilities. (a) General. The agency shall operate each program or activity so that the program or activity, when viewed in its entirety, is readily accessible to and usable by...

  6. 24 CFR 9.150 - Program accessibility: existing facilities.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... ACTIVITIES CONDUCTED BY THE DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT § 9.150 Program accessibility... shall operate each program or activity so that the program or activity, when viewed in its entirety, is... nature of a program or activity or in undue financial and administrative burdens. In those circumstances...

  7. 28 CFR 39.150 - Program accessibility: Existing facilities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... NONDISCRIMINATION ON THE BASIS OF HANDICAP IN PROGRAMS OR ACTIVITIES CONDUCTED BY THE DEPARTMENT OF JUSTICE § 39.150 Program accessibility: Existing facilities. (a) General. The agency shall operate each program or activity so that the program or activity, when viewed in its entirety, is readily accessible to and usable by...

  8. 45 CFR 1214.150 - Program accessibility: Existing facilities.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... ACTIVITIES CONDUCTED BY ACTION § 1214.150 Program accessibility: Existing facilities. (a) General. The agency shall operate each program or activity so that the program or activity, when viewed in its entirety, is... fundamental alteration in the nature of a program or activity or in undue financial and administrative burdens...

  9. 33 CFR 150.940 - Safety zones for specific deepwater ports.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false Safety zones for specific... SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Safety Zones, No Anchoring Areas, and Areas To Be Avoided § 150.940 Safety zones for specific deepwater ports. (a) Louisiana Offshore Oil Port...

  10. 33 CFR 150.940 - Safety zones for specific deepwater ports.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Safety zones for specific... SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Safety Zones, No Anchoring Areas, and Areas To Be Avoided § 150.940 Safety zones for specific deepwater ports. (a) Louisiana Offshore Oil Port...

  11. 33 CFR 150.940 - Safety zones for specific deepwater ports.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Safety zones for specific... SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Safety Zones, No Anchoring Areas, and Areas To Be Avoided § 150.940 Safety zones for specific deepwater ports. (a) Louisiana Offshore Oil Port...

  12. 33 CFR 150.940 - Safety zones for specific deepwater ports.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false Safety zones for specific... SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Safety Zones, No Anchoring Areas, and Areas To Be Avoided § 150.940 Safety zones for specific deepwater ports. (a) Louisiana Offshore Oil Port...

  13. 33 CFR 150.940 - Safety zones for specific deepwater ports.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false Safety zones for specific... SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Safety Zones, No Anchoring Areas, and Areas To Be Avoided § 150.940 Safety zones for specific deepwater ports. (a) Louisiana Offshore Oil Port...

  14. 33 CFR 150.602 - What occupational awareness training is required?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false What occupational awareness... Safety and Health (general) § 150.602 What occupational awareness training is required? (a) Each deepwater port operator must ensure that all port personnel are provided with information and training on...

  15. Analysis of laser produced plasmas of gold in the 1-7 nm region

    NASA Astrophysics Data System (ADS)

    Li, Bowen; Higashiguchi, Takeshi; Otsuka, Takamitsu; Yugami, Noboru; Dunne, Padraig; Kilbane, Deirdre; Sokell, Emma; O'Sullivan, Gerry

    2014-04-01

    Extreme ultraviolet (EUV) spectra from gold laser produced plasmas were recorded in the 1-7 nm region using two Nd:YAG lasers with pulse lengths of 150 ps and 10 ns, respectively, operating at a range of power densities. The maximum focused peak power density was 9.5 × 1013 W cm-2 for the former and 5.3 × 1012 W cm-2 for the latter. Two intense quasicontinuous intensity bands resulting from n = 4-n = 4 and n = 4-n = 5 unresolved transition arrays dominate the 4-5.5 and 1.5-3.6 nm regions of both spectra. Comparison with atomic structure calculations performed with the Cowan suite of atomic structure codes as well as consideration of previous experimental and theoretical results aided identification of the most prominent features in the spectra. For the ns spectrum, the highest ion stage that could be identified from the n = 4-n = 5 arrays was Au28+ while for the ps plasma the presence of significantly higher stages was deduced and lines due to 4d104f-4d94f2 transitions in Ag-like Au32+ give rise to the strongest observed features within the n = 4-n = 4 array while in the n = 4-n = 5 array it was possible to identify a number of previously unidentified spectral features as resulting from 4f-5g transitions in the spectra of Au XX to Au XXXIII.

  16. The Effect of Piston-Head Temperature on Knock-Limited Power

    NASA Technical Reports Server (NTRS)

    Imming, Harry S.

    1944-01-01

    To determine the effect of piston-head temperature on knock-limited power. Tests were made in a supercharged CFR engine over a range of fuel-air ratios from 0.055 to 0.120, using S-3 reference fuel, AN-F-28, Amendment-2, aviation gasoline, and AN-F-28 plus 2 percent xylidines by weight. Tests were run at a compression ratio of 7.0 with inlet-air temperatures of 150 F and 250 F and at a compression ratio of 8.0 with an inlet-air temperature of 250 F. All other engine conditions were held constant. The piston-head temperature was varied by circulation of oil through passages in the crown of a liquid-cooled piston. This method of piston cooling decreased the piston-head temperature about 80 F. The data are not intended to constitute a recommendation as to the advisability of piston cooling in practice.

  17. Thermal-mechanical fatigue test apparatus for metal matrix composites and joint attachments

    NASA Technical Reports Server (NTRS)

    Westfall, Leonard J.; Petrasek, Donald W.

    1988-01-01

    Two thermal-mechanical fatigue (TMF) test facilities were designed and developed, one to test tungsten fiber reinforced metal matrix composite specimens at temperature up to 1430C (2600F) and another to test composite/metal attachment bond joints at temperatures up to 760F (1400F). The TMF facility designed for testing tungsten fiber reinforced metal matrix composites permits test specimen temperature excursions from room temperature to 1430C (2600F) with controlled heating and loading rates. A strain-measuring device measures the strain in the test section of the specimen during each heating and cooling cycle with superimposed loads. Data is collected and recorded by a computer. The second facility is designed to test composite/metal attachment bond joints and to permit heating to a maximum temperature of 760C (1400F) within 10 min and cooling to 150C (300F) within 3 min. A computer controls specimen temperature and load cycling.

  18. A Search for Lost Planets in the Kepler Multi-planet Systems and the Discovery of the Long-period, Neptune-sized Exoplanet Kepler-150 f

    NASA Astrophysics Data System (ADS)

    Schmitt, Joseph R.; Jenkins, Jon M.; Fischer, Debra A.

    2017-04-01

    The vast majority of the 4700 confirmed planets (CPs) and planet candidates discovered by the Kepler mission were first found by the Kepler pipeline. In the pipeline, after a transit signal is found, all data points associated with those transits are removed, creating a “Swiss cheese”-like light curve full of holes, which is then used for subsequent transit searches. These holes could render an additional planet undetectable (or “lost”). We examine a sample of 114 stars with 3+ CPs to evaluate the effect of this “Swiss cheesing.” A simulation determines that the probability that a transiting planet is lost due to the transit masking is low, but non-negligible, reaching a plateau at ˜3.3% lost in the period range of P = 400-500 days. We then model all planet transits and subtract out the transit signals for each star, restoring the in-transit data points, and use the Kepler pipeline to search the transit-subtracted (I.e., transit-cleaned) light curves. However, the pipeline did not discover any credible new transit signals. This demonstrates the validity and robustness of the Kepler pipeline’s choice to use transit masking over transit subtraction. However, a follow-up visual search through all the transit-subtracted data, which allows for easier visual identification of new transits, revealed the existence of a new, Neptune-sized exoplanet (Kepler-150 f) and a potential single transit of a likely false positive (FP) (Kepler-208). Kepler-150 f (P = 637.2 days, {R}{{P}}={3.64}-0.39+0.52 R⊕) is confirmed with >99.998% confidence using a combination of the planet multiplicity argument, an FP probability analysis, and a transit duration analysis.

  19. Performance and Characterization of Shear Ties for Use in Insulated Precast Concrete Sandwich Wall Panels

    DTIC Science & Technology

    2010-11-01

    stainless 14 steel, galvanized carbon steel, carbon- fiber -reinforced polymer (CFRP), glass- fiber -reinforced polymer 15 (GFRP), and basalt - fiber ...CFRP Grid, (E) Universal Building Products GFRP Teplo Tie, and (F) Universal Building Products 6 Basalt FRP RockBar. Traditional steel connections...1.6 E Universal Building Products TeploTie GFRP Tie 10 mm dia. x 150 mm F RockBar Basalt FRP Bar 7 in. x 5/16 in. G TSA Manufacturing C-Clip

  20. 1-Bromo-2,3,5,6-tetra­fluoro-4-nitro­benzene

    PubMed Central

    Stein, Mario; Schwarzer, Anke; Hulliger, Jürg; Weber, Edwin

    2011-01-01

    In the title compound, C6BrF4NO2, the nitro group is twisted by 41.7 (3)° with reference to the arene ring mean plane. The main inter­actions stabilizing the crystal structure include O⋯Br contacts [3.150 (2) and 3.201 (2) Å], while F⋯F inter­actions are minor [2.863 (3)–2.908 (3) Å]. PMID:21837056

  1. T700 Blisk and Impeller Manufacturing Process Development Program.

    DTIC Science & Technology

    1979-11-01

    700(40) Reworked Media Temperature - 790 F Average Media Pressure - 200 psi Total Cycles (Test No. 1) - 40 Total Cycles (Test No. 2) - 20 Total Time...36A(73), - 700(40" Media Temperature - 80F Average Media Pressure - 150 psi Total Cycles - 52 Total Time - 95 Minutes Some difficulty was...61)-36A(73)-700( 4O)Media Temperature - 79OF average Media Pressure - 200 psi Time - 40 cycles - 72 minutes Time - 60 cycles - 109 minutes Time - 80

  2. High Speed Compressor Study

    DTIC Science & Technology

    2011-12-21

    ra tin g Fr eq...G as S pr in g Pi st on M as s (g ra m ) R es on an t F R eq ue nc y (H z) Gas Spring End Clearance (mm) Gas Spring Characteristics Resonant...0 50 100 150 200 250 20 30 40 50 60 70 80 90 R es on an t F R eq ue nc y (H z) G as S pr in g Pi st on M as s (g ra m ) Gas Spring

  3. Ultra-Low-Dropout Linear Regulator

    NASA Technical Reports Server (NTRS)

    Thornton, Trevor; Lepkowski, William; Wilk, Seth

    2011-01-01

    A radiation-tolerant, ultra-low-dropout linear regulator can operate between -150 and 150 C. Prototype components were demonstrated to be performing well after a total ionizing dose of 1 Mrad (Si). Unlike existing components, the linear regulator developed during this activity is unconditionally stable over all operating regimes without the need for an external compensation capacitor. The absence of an external capacitor reduces overall system mass/volume, increases reliability, and lowers cost. Linear regulators generate a precisely controlled voltage for electronic circuits regardless of fluctuations in the load current that the circuit draws from the regulator.

  4. Use of intravoxel incoherent motion diffusion-weighted imaging to detect early changes in diabetic kidneys.

    PubMed

    Deng, Yi; Yang, Biran; Peng, Yan; Liu, Zhiqiang; Luo, Jinwen; Du, Guoxin

    2018-03-14

    The purpose of the study was to examine differences in kidney intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) parameters in early-stage diabetic patients versus healthy controls. Nineteen type 2 diabetic patients (group A) with a urinary albumin-to-creatinine ratio (ACR) < 30 mg/g and an estimated glomerular filtration rate (eGFR) of 80-120 mL/(min 1.73 m 2 ) and twelve healthy volunteers (group B) were recruited. Kidneys were scanned with 1.5-Tesla IVIM-DWI. Nine b values (0, 50, 100, 150, 200, 300, 400, 600, and 800 s/mm 2 ) were used. The parameters derived from IVIM-DWI were calculated for each kidney by two radiologists and included the perfusion fraction (f), diffusion coefficient (D), and pseudo-diffusion coefficient (D*). The mean values of f, D, and D* were calculated by selecting multiple regions of interest in the kidney. The diagnostic performance of the f, D, and D* values for the diagnosis of early diabetic kidney changes was determined by receiver operating characteristic analysis. Three radiologists independently measured the parameters derived from IVIM-DWI in the two groups by free-hand placing regions of interest, and the interclass coefficients (ICCs) were analyzed by SPSS.16.0 software. The f values of the kidneys were significantly higher in diabetic patients than in healthy volunteers. The D value of the kidneys was significantly lower in diabetic patients than in healthy volunteers. No significant differences in the D* values of the kidneys were observed between diabetic patients and healthy volunteers. The D values of the right kidneys were significantly higher than those of the left kidneys in both groups. The results of the receiver operating characteristic analysis were as follows: left kidney-f value AUC = 0.650 (cutoff point ≥ 27.49%) and D value AUC = 0.752 (cutoff point ≤ 1.68 × 10 -3  mm 2 /s); and right kidney-f value AUC = 0.650 (cutoff point ≥ 28.24%) and D value AUC = 0.752 (cutoff point ≤ 1.81 × 10 -3 mm 2 /s). The diagnostic performance of the D* value was very low (AUC < 0.6). No significant differences were present between the areas under the curves of the f and D values (P > 0.05). The ICCs of the f value and D value were between 0.637 and 0.827. The ICC of the D* value was less than 0.3. The results of our study suggest that changes in kidneys detected by IVIM-DWI may serve as indicators of early diabetic kidney disease.

  5. Long Term Mortality and Cancer Risk in Irradiated Rhesus Monkeys

    DTIC Science & Technology

    1990-05-01

    Subcutis (Leg) Fibrosarcoma 108.1 M Proton 55 6.0 Mucosa ( Nasal ) Carcinoma 116.4 M Proton 138 5.0 Muscle Sarcoma 122.6 F X-ray 2 5.38 Subcutis (Elbow...55 6.0 Brain Glioblastoma 17.2 M Proton 400 1.0 Reticuloendothelium Acute leukemia 32.7 M Electron 1.6 15.0 Subcutis (Leg) Fibrosarcoma 40.5 M Proton...55 8.0 Brain Glioblastoma 42.9 M Electron 1.6 15.0 Subcutis (Leg) Fibrosarcoma 54.3 M Proton 55 6.0 Subcutis (Leg) Fibrosarcoma 54.5 M Proton 55 6.0

  6. 14 CFR 161.7 - Limitations.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... operations, or limit the hours of Stage 2 or Stage 3 aircraft operations, at the airport. (b) The notice... November 5, 1990, where the amendment does not reduce or limit aircraft operations or affect aircraft... working group (outside of the process established by 14 CFR part 150) with a local airport operator to...

  7. Influence of rotational speed, torque and operator proficiency on failure of Greater Taper files.

    PubMed

    Yared, G M; Dagher, F E Bou; Machtou, P; Kulkarni, G K

    2002-01-01

    The purpose of this study was to evaluate the influence of rotational speed. torque, and operator experience on the incidence of locking, deformation, and separation of instruments when using a specific Ni-Ti rotary instrumentation technique in extracted human teeth. Greater Taper Ni-Ti rotary instruments (GT) were used in a crown-down technique. In one group (rotational speed evaluation) of canals (n = 300) speeds of 150, 2 50 and 350 r.p.m. (subgroups 1, 2 and 3) were used. Each one of the subgroups included 100 canals. In a second group (evaluation of torque) (n = 300) torque was set at 20, 30 and 55 Ncm (subgroups 4, 5 and 6). In the third group (evaluation of operator proficiency) (n = 300 three operators with varying experience (subgroups 7, 8 and 9) were also compared. Each subgroup included the use of 10 sets of GT rotary instruments and 100 canals of extracted human molars. Each set of instruments was used in up to 10 canals and sterilized before each case. NaOCl 2.5% was used as an irrigant. The number of locked, deformed, and separated instruments was recorded for each group. Statistical analysis was carried out with pairwise comparisons using Fisher's exact tests for each of the failure type. When the influence of rotational speed was evaluated, instrument deformation and separation did not occur in subgroups 1 (150) r.p.m.), 2 (250 r.p.m.), and 3 (350) r.p.m.). Instrument locking occurred in subgroup 3 only. Statistical analysis demonstrated a significant difference between the 150 and 350 r.p.m. groups and between the 250 and 350 r.p.m. groups with respect to instrument locking. In torque evaluation, neither separation, deformation nor locking occurred during the use of the instruments, at 150 r.p.m., and at the different torque values. When the operators were compared, although two instruments were separated in canals prepared by the least experienced operator. Fisher's exact tests did not demonstrate a significant difference between the three subgroups. Instrument locking, deformation, and separation did not occur with the most experienced operator. None of the instruments separated with the trained operator. Preclinical training in the use of the GT rotary instruments when used with a crown-down technique at 150 r.p.m. was crucial in avoiding instrument separation and reducing the incidence of instrument locking and deformation.

  8. Electromagnetic induction of foam-based nanoscale zerovalent iron (NZVI) particles to thermally enhance non-aqueous phase liquid (NAPL) volatilization in unsaturated porous media: Proof of concept.

    PubMed

    Srirattana, Supawan; Piaowan, Kitsanateen; Lowry, Gregory V; Phenrat, Tanapon

    2017-09-01

    Nanoscale zerovalent iron (NZVI) is a promising remediation agent for volatile organic compound (VOC) contamination in saturated sub-surfaces, but is rarely applied to the vadose zone as there are not enough water molecules in the unsaturated zone to participate in reductive dechlorination. In this study, we evaluated the possibility of using foam as a carrying vehicle to emplace NZVI in unsaturated porous media followed by the application of low frequency-electromagnetic field (LF-EMF) to enhance VOC volatilization in laboratory batch reactors. We found that the optimal condition for generating foam-based NZVI (F-NZVI) was using sodium lauryl ether sulfate (SLES) at a concentration of 3% (w/w) and a N 2 flow rate of 500 mL/min. Also, F-NZVI could carry as much as 41.31 g/L of NZVI in the liquid phase of the foam and generate heat to raise ΔT to 77 °C in 15 min under an applied LF-EMF (150 kHz and 13 A). Under these conditions, F-NZVI together with LF-EMF enhanced trichloroethylene (TCE) volatilization from TCE-dense non-aqueous phase liquid (DNAPL) in unsaturated sand by 39.51 ± 6.59-fold compared to reactors without LF-EMF application. This suggested that using F-NZVI together with LF-EMF could theoretically be an alternative to radio frequency heating (RFH) as it requires a much lower irradiation frequency (336-fold lower), which should result in significantly lower capital and operational costs compared to RFH. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. 21 CFR 177.1970 - Vinyl chloride-lauryl vinyl ether copolymers.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... filter paper with the aid of suction. Transfer the filtrate to flat glass dishes that are warmed on a hot.... Maintain the temperature of the contents of the flask at 150 °F for 2 hours using a hot plate while also...

  10. 21 CFR 177.1970 - Vinyl chloride-lauryl vinyl ether copolymers.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... filter paper with the aid of suction. Transfer the filtrate to flat glass dishes that are warmed on a hot.... Maintain the temperature of the contents of the flask at 150 °F for 2 hours using a hot plate while also...

  11. 21 CFR 177.1970 - Vinyl chloride-lauryl vinyl ether copolymers.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... filter paper with the aid of suction. Transfer the filtrate to flat glass dishes that are warmed on a hot.... Maintain the temperature of the contents of the flask at 150 °F for 2 hours using a hot plate while also...

  12. 21 CFR 177.1970 - Vinyl chloride-lauryl vinyl ether copolymers.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... filter paper with the aid of suction. Transfer the filtrate to flat glass dishes that are warmed on a hot.... Maintain the temperature of the contents of the flask at 150 °F for 2 hours using a hot plate while also...

  13. Project ABLE: (Atmospheric Balloonborne Lidar Experiment)

    NASA Astrophysics Data System (ADS)

    Shepherd, O.; Aurilio, G.; Bucknam, R. D.; Hurd, A. G.; Sheehan, W. H.

    1985-03-01

    Project ABLE (Atmospheric Balloonborne Lidar Experiment) is part of the A.F. Geophysics Laboratory's continuing interest in developing techniques for making remote measurements of atmospheric quantities such as density, pressure, temperatures, and wind motions. The system consists of a balloonborne lidar payload designed to measure neutral molecular density as a function of altitude from ground level to 70 km. The lidar provides backscatter data at the doubled and tripled frequencies of a Nd:YAG laser, which will assist in the separation of the molecular and aerosol contributions and subsequent determination of molecular and aerosol contributions and subsequent determination of molecular density vs altitude. The object of this contract was to fabricate and operate in a field test a balloonborne lidar experiment capable of performing nighttime atmospheric density measurements up to 70 km altitude with a resolution of 150 meters. The payload included a frequency-doubled and -tripled Nd:YAG laser with outputs at 355 and 532 nm; a telescoped receiver with PMT detectors; a command-controlled optical pointing system; and support system, including thermal control, telmetry, command, and power. Successful backscatter measurements were made during field operations which included a balloon launch from Roswell, NM and a flight over the White Sands Missile Range.

  14. Changing lamp type and position to improve lighting quality

    NASA Astrophysics Data System (ADS)

    Anizar; Syahputri, K.; Sari, RM; Rizkya, I.; Hardianti, DA

    2018-03-01

    This study investigates the lighting quality on the production floor in a cigarette paper industry by measuring illumination level and luminance. Cigarette paper inspection is performed manually by operators, and the criteria of defects are the cigarette paper has a hole, is rough and dirty. Operators complain that the room is pretty dark, which makes them unable to see clearly the cigarette paper defect. The government of Indonesia Health Ministerial Decree No 1405 The Year 2002 states that illumination level for continuous manual labor is 200 lux. Illumination level is measured for four days at 08.00, 10.00, 12.30, and 14.00 o’clock with 4 in 1 environmental meter. From the measurement result, it is found that using 7 LED lamps of 60 Watts can produce average illumination level of 70 lux. Low illuminance is caused by illumination level that does not meet the need 0f 569.759 lumen. Alternatives that can be used to increase lumen number are changing lamp type and position. One of the possibilities is using 24 LED of 138 Watts set 5.7 meters apart from one another can meet this demand. Another is using 5 LED of 150 Watts installed above the field of work.

  15. 47 CFR 101.1333 - Interference protection criteria.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... is in watts, D is in meters, and the power is relative to an isotropic radiator. The technical... for master stations operating at a maximum power shall not exceed 150 meters. Above 150 meters, the... Reduction Table Antenna height above average terrain (meters) EIRP Watts dBW ERP Watts dBW Above 305 200 23...

  16. 40 CFR 60.53b - Standards for municipal waste combustor operating practices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Circulating fluidized bed combustor 100 4 Pulverized coal/refuse-derived fuel mixed fuel-fired combustor 150 4 Spreader stoker coal/refuse-derived fuel mixed fuel-fired combustor 150 24 a Measured at the combustor... activated carbon injection rate during dioxin/furan or mercury testing. [60 FR 65419, Dec. 19, 1995, as...

  17. 33 CFR 150.622 - What are the warning sign requirements?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false What are the warning sign... SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Workplace Safety and Health Warning Signs § 150.622 What are the warning sign requirements? The construction and use of warning signs must be in...

  18. 33 CFR 150.622 - What are the warning sign requirements?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false What are the warning sign... SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Workplace Safety and Health Warning Signs § 150.622 What are the warning sign requirements? The construction and use of warning signs must be in...

  19. 33 CFR 150.622 - What are the warning sign requirements?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false What are the warning sign... SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Workplace Safety and Health Warning Signs § 150.622 What are the warning sign requirements? The construction and use of warning signs must be in...

  20. 33 CFR 150.622 - What are the warning sign requirements?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false What are the warning sign... SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Workplace Safety and Health Warning Signs § 150.622 What are the warning sign requirements? The construction and use of warning signs must be in...

  1. 14 CFR 171.109 - Performance requirements.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ...-locked so that within the half course sector, the demodulated 90 Hz and 150 Hz wave forms pass through... the combined 90 Hz and 150 Hz wave form. However, the phase need not be measured within the half... identification signals, if that operation does not interfere with the basic function. If a channel is provided...

  2. 13 CFR 120.150 - What are SBA's lending criteria?

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 13 Business Credit and Assistance 1 2011-01-01 2011-01-01 false What are SBA's lending criteria... Policies Applying to All Business Loans Credit Criteria for Sba Loans § 120.150 What are SBA's lending criteria? The applicant (including an Operating Company) must be creditworthy. Loans must be so sound as to...

  3. Evaluation of electrosurgical interference to low-power spread-spectrum local area net transceivers.

    PubMed

    Gibby, G L; Schwab, W K; Miller, W C

    1997-11-01

    To study whether an electrosurgery device interferes with the operation of a low-power spread-spectrum wireless network adapter. Nonrandomized, unblinded trials with controls, conducted in the corridor of our institution's operating suite using two portable computers equipped with RoamAbout omnidirectional 250 mW spread-spectrum 928 MHz wireless network adapters. To simulate high power electrosurgery interference, a 100-watt continuous electrocoagulation arc was maintained five feet from the receiving adapter, while device reported signal to noise values were measured at 150 feet and 400 feet distance between the wireless-networked computers. At 150 feet range, and with continuous 100-watt electrocoagulation arc five feet from one computer, error-corrected local area net throughput was measured by sending and receiving a large file multiple times. The reported signal to noise (N = 50) decreased with electrocoagulation from 36.42+/-3.47 (control) to 31.85+/-3.64 (electrocoagulation) (p < 0.001) at 400 feet inter-adapter distance, and from 64.53+/-1.43 (control) to 60.12+/-3.77 (electrocoagulation) (p < 0.001) at 150 feet inter-adapter distance. There was no statistically significant change in network throughput (average 93 kbyte/second) at 150 feet inter-adapter distance, either transmitting or receiving during continuous 100 Watt electrocoagulation arc. The manufacturer indicates "acceptable" performance will be obtained with signal to noise values as low as 20. In view of this, while electrocoagulation affects this spread spectrum network adapter, the effects are small even at 400 feet. At a distance of 150 feet, no discernible effect on network communications was found, suggesting that if other obstructions are minimal, within a wide range on one floor of an operating suite, network communications may be maintained using the technology of this wireless spread spectrum network adapter. The impact of such adapters on cardiac pacemakers should be studied. Wireless spread spectrum network adapters are an attractive technology for mobile computer communications in the operating room.

  4. Influence of the St. Patrick's Day geomagnetic storm on the mid-latitude E and F regions.

    NASA Astrophysics Data System (ADS)

    Garnett Marques Brum, C.; Raizada, S.; Hajra, R.; Echer, E.

    2016-12-01

    We will discuss the impact of St. Patrick's Day geomagnetic storm that occurred between 17 -19 March 2015 on the E and F-region of the ionosphere. During the initial phase of this event the foF2 increases about 3 MHz in respect to the quiet period followed by a sharp decrease in foF2 values of about 10 MHz, reaching -6 MHz in the end of the main phase (Dst dropped to -225 nT on 17th March) as observed using Incoherent Scatter Radar and ionosonde located in Puerto Rico. However, during the rest of the disturbance, the F-region showed an increase in the electron concentration, in particular during the nighttime periods. Large fluctuations were observed in hmF2 with variations up to 150 km relative to quiet time period. This paper will also investigate the coupling between high and mid latitudes along with E and F region of the ionosphere over Arecibo.

  5. Liver fibrosis: in vivo evaluation using intravoxel incoherent motion-derived histogram metrics with histopathologic findings at 3.0 T.

    PubMed

    Hu, Fubi; Yang, Ru; Huang, Zixing; Wang, Min; Zhang, Hanmei; Yan, Xu; Song, Bin

    2017-12-01

    To retrospectively determine the feasibility of intravoxel incoherent motion (IVIM) imaging based on histogram analysis for the staging of liver fibrosis (LF) using histopathologic findings as the reference standard. 56 consecutive patients (14 men, 42 women; age range, 15-76, years) with chronic liver diseases (CLDs) were studied using IVIM-DWI with 9 b-values (0, 25, 50, 75, 100, 150, 200, 500, 800 s/mm 2 ) at 3.0 T. Fibrosis stage was evaluated using the METAVIR scoring system. Histogram metrics including mean, standard deviation (Std), skewness, kurtosis, minimum (Min), maximum (Max), range, interquartile (Iq) range, and percentiles (10, 25, 50, 75, 90th) were extracted from apparent diffusion coefficient (ADC), true diffusion coefficient (D), pseudo-diffusion coefficient (D*), and perfusion fraction (f) maps. All histogram metrics among different fibrosis groups were compared using one-way analysis of variance or nonparametric Kruskal-Wallis test. For significant parameters, receivers operating characteristic curve (ROC) analyses were further performed for the staging of LF. Based on their METAVIR stage, the 56 patients were reclassified into three groups as follows: F0-1 group (n = 25), F2-3 group (n = 21), and F4 group (n = 10). The mean, Iq range, percentiles (50, 75, and 90th) of D* maps between the groups were significant differences (all P < 0.05). Area under the ROC curve (AUC) of the mean, Iq range, 50, 75, and 90th percentile of D* maps for identifying significant LF (≥F2 stage) was 0.901, 0.859, 0.876, 0.943, and 0.886 (all P < 0.0001), respectively; for diagnosing severe fibrosis or cirrhosis (F4), AUC was 0.917, 0.922, 0.943, 0.985, and 0.939 (all P < 0.0001), respectively. The histogram metrics of ADC, D, and f maps demonstrated no significant difference among the groups (all P > 0.05). Histogram analysis of D* map derived from IVIM can be used to stage liver fibrosis in patients with CLDs and provide more quantitative information beyond the mean value.

  6. FACTORS AFFECTING THE USE OF CAF2:MN THERMOLUMINESCENT DOSIMETERS FOR LOW-LEVEL ENVIRONMENTAL RADIATION MONITORING

    EPA Science Inventory

    An investigation was made of factors affecting the use of commercially-produced CaF2:Mn thermoluminescent dosimeters for low level environmental radiation monitoring. Calibration factors and self-dosing rates were quantified for 150 thermoluminescent dosimeters. Laboratory studie...

  7. High sensitivity microchannel plate detectors for space extreme ultraviolet missions.

    PubMed

    Yoshioka, K; Homma, T; Murakami, G; Yoshikawa, I

    2012-08-01

    Microchannel plate (MCP) detectors have been widely used as two-dimensional photon counting devices on numerous space EUV (extreme ultraviolet) missions. Although there are other choices for EUV photon detectors, the characteristic features of MCP detectors such as their light weight, low dark current, and high spatial resolution make them more desirable for space applications than any other detector. In addition, it is known that the photocathode can be tailored to increase the quantum detection efficiency (QDE) especially for longer UV wavelengths (100-150 nm). There are many types of photocathode materials available, typically alkali halides. In this study, we report on the EUV (50-150 nm) QDE evaluations for MCPs that were coated with Au, MgF(2), CsI, and KBr. We confirmed that CsI and KBr show 2-100 times higher QDEs than the bare photocathode MCPs, while Au and MgF(2) show reduced QDEs. In addition, the optimal geometrical parameters for the CsI deposition were also studied experimentally. The best CsI thickness was found to be 150 nm, and it should be deposited on the inner wall of the channels only where the EUV photons initially impinge. We will also discuss the techniques and procedures for reducing the degradation of the photocathode while it is being prepared on the ground before being deployed in space, as adopted by JAXA's EXCEED mission which will be launched in 2013.

  8. Joint Networking Command and Control (C2) Communications Among Distributed Operations, JCAS, and Joint Fires

    DTIC Science & Technology

    2007-06-01

    fasteners. Enviromental Spec Storage Temperature: -26 to 160 °F, Operating Temperature: -22 to 160 °F, Operating Humidity Range: 5% to 100% Non...Accessories Double 90° tongue and groove case design, with anti-tamper fasteners. Enviromental Spec Storage Temperature: -26 to 160 °F, Operating

  9. 47 CFR 25.256 - Special Requirements for operations in the 3.65-3.7 GHz band.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ..., part 90 that seeks to place base and fixed stations in operation within 150 km of a primary earth station, licensees of earth stations operating on a primary basis in the Fixed-Satellite Service in the 3...

  10. 47 CFR 25.256 - Special Requirements for operations in the 3.65-3.7 GHz band.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ..., Part 90 that seeks to place base and fixed stations in operation within 150 km of a primary earth station, licensees of earth stations operating on a primary basis in the Fixed-Satellite Service in the 3...

  11. 47 CFR 25.256 - Special Requirements for operations in the 3.65-3.7 GHz band.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ..., Part 90 that seeks to place base and fixed stations in operation within 150 km of a primary earth station, licensees of earth stations operating on a primary basis in the fixed satellite service in the 3...

  12. Measurement of mechanical and thermophysical properties of dimensionally stable materials for space applications

    NASA Technical Reports Server (NTRS)

    Rawal, Suraj P.; Misra, Mohan S.

    1992-01-01

    Mechanical, thermal, and physical property test data was generated for as-fabricated advanced composite materials at room temperature (RT), -150 and 250 F. The results are documented of mechanical and thermophysical property tests of IM7/PEEK and discontinuous SiC/Al (particulate (p) and whisker (w) reinforced) composites which were tested at three different temperatures to determine the effect of temperature on material properties. The specific material systems tested were IM7/PEEK (0)8, (0, + or - 45, 90)s, (+ or - 30, 04)s, 25 vol. pct. (v/o) SiCp/Al, and 25 v/o SiCw/Al. RT material property results of IM7/PEEK were in good agreement with the predicted values, providing a measure of consolidation integrity attained during fabrication. Results of mechanical property tests indicated that modulus values at each test temperature were identical, whereas the strength (e.g., tensile, compressive, flexural, and shear) values were the same at -150 F, and RT, and gradually decreased as the test temperature was increased to 250 F. Similar trends in the strength values was also observed in discontinuous SiC/Al composites. These results indicate that the effect of temperature was more pronounced on the strength values than modulus values.

  13. Mining Permits - Division of Mining, Land, and Water

    Science.gov Websites

    are issued for a term of 1-5 years. An application for a "single year" operation costs $150 ). Federal Operators: If your operation involves federal land managed by the Bureau of Land Management (BLM issues miners the Alaska Pollutant Discharge Elimination System (APDES) General Permit. If the operation

  14. 33 CFR 156.150 - Declaration of inspection.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... operation if not at a facility; (3) The date and time the transfer operation is started; (4) A list of the... transfer operations on the transferring vessel or facility and a space for the date, time of signing... transferring product; and (6) The date and time the transfer operation is completed. (d) The form for the...

  15. 33 CFR 156.150 - Declaration of inspection.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... operation if not at a facility; (3) The date and time the transfer operation is started; (4) A list of the... transfer operations on the transferring vessel or facility and a space for the date, time of signing... transferring product; and (6) The date and time the transfer operation is completed. (d) The form for the...

  16. 33 CFR 156.150 - Declaration of inspection.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... operation if not at a facility; (3) The date and time the transfer operation is started; (4) A list of the... transfer operations on the transferring vessel or facility and a space for the date, time of signing... transferring product; and (6) The date and time the transfer operation is completed. (d) The form for the...

  17. 33 CFR 156.150 - Declaration of inspection.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... operation if not at a facility; (3) The date and time the transfer operation is started; (4) A list of the... transfer operations on the transferring vessel or facility and a space for the date, time of signing... transferring product; and (6) The date and time the transfer operation is completed. (d) The form for the...

  18. 33 CFR 156.150 - Declaration of inspection.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... operation if not at a facility; (3) The date and time the transfer operation is started; (4) A list of the... transfer operations on the transferring vessel or facility and a space for the date, time of signing... transferring product; and (6) The date and time the transfer operation is completed. (d) The form for the...

  19. Diffusion and the dynamics of displacive phase transitions in cryolite (Na3AlF6) and chiolite (Na5Al3F14): Multi-nuclear NMR studies

    NASA Astrophysics Data System (ADS)

    Spearing, Dane R.; Stebbins, Jonathan F.; Farnan, Ian

    1994-10-01

    Cryolite is a mixed-cation perovskite (Na2(NaAl)F6) which undergoes a monoclinic to orthorhombic displacive phase transition at ˜550° C. Chiolite (Na5Al3F14) is associated with cryolite in natural deposits, and consists of sheets of corner sharing [AlF6] octahedra interlayered with edge-sharing [NaF6] octahedra. Multi-nuclear NMR line shape and relaxation time (T1) studies were performed on cryolite and chiolite in order to gain a better understanding of the atomic motions associated with the phase transition in cryolite, and Na diffusion in cryolite and chiolite. 27Al, 23Na, and 19F static NMR spectra and T1's in cryolite suggest that oscillatory motions of the [AlF6] octahedra among four micro-twin and anti-phase domains in α-cryolite begin at least 150° C below the transition temperature and persist above it. Variable temperature 23Na MAS NMR further indicates diffusional exchange at a rate of at least 13 kHz between the Na sites by the time the transition temperature is reached. 27Al and 23Na T1's show the same behavior with increasing temperature, indicating the same relaxation mechanisms are responsible for both. The first order nature of the cryolite transition is apparent as a jump in the 23Na and 27Al T1's. Above the transition temperature, the T1's decrease slightly indicating that the motions responsible for the drop in T1, are still present above the transition, further supporting the dynamic nature of the high temperature phase of cryolite. Chiolite 23Na static spectra decrease in linewidth with increasing temperature, indicating increased Na diffusion, which is interpreted as occurring within the [NaF6] sheets in the chiolite structure, but not between the two different Na sites. 27Al and 23Na T1's show similar behavior as in cryolite, but there is no discontinuity due to a phase transition. 19F T1's are constant from room temperature to 150° C indicating no oscillatory motion of the [AlF6] octahedra in chiolite.

  20. Attention and the evolution of Hollywood film.

    PubMed

    Cutting, James E; DeLong, Jordan E; Nothelfer, Christine E

    2010-03-01

    Reaction times exhibit a spectral patterning known as 1/f, and these patterns can be thought of as reflecting time-varying changes in attention. We investigated the shot structure of Hollywood films to determine if these same patterns are found. We parsed 150 films with release dates from 1935 to 2005 into their sequences of shots and then analyzed the pattern of shot lengths in each film. Autoregressive and power analyses showed that, across that span of 70 years, shots became increasingly more correlated in length with their neighbors and created power spectra approaching 1/f. We suggest, as have others, that 1/f patterns reflect world structure and mental process. Moreover, a 1/f temporal shot structure may help harness observers' attention to the narrative of a film.

  1. Design and Lithographic Characteristics of Alicyclic Fluoropolymer for ArF Chemically Amplified Resists

    NASA Astrophysics Data System (ADS)

    Maeda, Katsumi; Nakano, Kaichiro; Shirai, Masamitsu

    2006-12-01

    We designed a novel alicyclic fluoropolymer, poly[3-hydroxy-4-(hexafluoro-2-hydroxyisopropyl)tricyclodecene], as an ArF (193 nm) chemically amplified resist. This fluoropolymer has a hexafluoroisopropanol group as an alkaline soluble unit and a hydroxyl group for improving adhesion. This polymer also exhibited a high transparency of 93%/150 nm at 193 nm, high thermal stability (355 °C), and a good adhesion to a Si substrate compared with a poly(norbornene) with a hexafluoroisopropanol group. The etching rate of our developed fluoropolymer for CF4 gas was 1.29 times that of the KrF resist. Moreover, a chemically amplified positive resist comprising an ethoxymethyl-protected polymer and a photoacid generator achieved a 110 nm line-and-space pattern with an ArF exposure.

  2. High single-spatial-mode pulsed power from 980 nm emitting diode lasers

    NASA Astrophysics Data System (ADS)

    Hempel, Martin; Tomm, Jens W.; Elsaesser, Thomas; Bettiati, Mauro

    2012-11-01

    Single-spatial-mode pulsed powers as high as 13 W and 20 W in 150 and 50 ns pulses, respectively, are reported for 980 nm emitting lasers. In terms of energy, single-spatial-mode values of up to 2 μJ within 150 ns pulses are shown. In this high-power pulsed operation, the devices shield themselves from facet degradation, being the main degradation source in continuous wave (cw) operation. Our results pave the way towards additional applications while employing available standard devices, which have originally been designed as very reliable cw fiber pumps.

  3. Thermal-mechanical fatigue test apparatus for metal matrix composites and joint attachments

    NASA Technical Reports Server (NTRS)

    Westfall, L. J.; Petrasek, D. W.

    1985-01-01

    Two thermal-mechanical fatigue (TMF) test facilities were designed and developed, one to test tungsten fiber reinforced metal matrix composite specimens at temperature up to 1430C (2600F) and another to test composite/metal attachment bond joints at temperatures up to 760C (1400 F). The TMF facility designed for testing tungsten fiber reinforced metal matrix composites permits test specimen temperature excursions from room temperature to 1430C (2600F) with controlled heating and loading rates. A strain-measuring device measures the strain in the test section of the specimen during each heating and cooling cycle with superimposed loads. Data is collected and recorded by a computer. The second facility is designed to test composite/metal attachment bond joints and to permit heating to a maximum temperature of 760C (1400F) within 10 min and cooling to 150C (300F) within 3 min. A computer controls specimen temperature and load cycling.

  4. Kinetics of ATP hydrolysis catalyzed by isolated TF1 and reconstituted TF0F1 ATPase.

    PubMed

    Rögner, M; Gräber, P

    1986-09-01

    The rate of ATP hydrolysis catalyzed by isolated TF1 and reconstituted TF0F1 was measured as a function of the ATP concentration in the presence of inhibitors [ADP, Pi and 3'-O-(1-naphthoyl)ATP]. ATP hydrolysis can be described by Michaelis-Menten kinetics with Km(TF1) = 390 microM and Km (TF0F1) = 180 microM. The inhibition constants are for ADP Ki(TF1) = 20 microM and Ki(TF0F1) = 100 microM, for 3'-O-(1-naphthoyl)ATP Ki(TF1) = 150 microM and Ki(TF0F1) = 3 microM, and for Pi Ki(TF1) = 60 mM. From these results it is concluded that upon binding of TF0 to TF1 the mechanism of ATP hydrolysis catalyzed by TF1 is not changed qualitatively; however, the kinetic constants differ quantitatively.

  5. Influence of rotational speed, torque and operator's proficiency on ProFile failures.

    PubMed

    Yared, G M; Bou Dagher, F E; Machtou, P

    2001-01-01

    The purpose of this study was to evaluate the influence of rotational speed, torque, and operator experience with a specific Ni-Ti rotary instrumentation technique on the incidence of locking, deformation and separation of instruments. ProFile Ni-Ti rotary instruments (PRI) sizes 40-15 with a 6% taper were used in a crown-down technique. In one group of canals (n = 300) speeds of 150, 250 and 350 rpm (subgroups 1, 2 and 3) were used. Each one of the subgroups included 100 canals. In a second group (n = 300) torque was set at 20, 30 and 55 Ncm (subgroups 4, 5 and 6). In the third group (n = 300) three operators with varying experience (subgroups 7, 8 and 9) were also compared. Each subgroup included the use of 10 sets of PRI and 100 canals of extracted human molars. Each set of PRI was used in up to 10 canals and then sterilized before each case. NaOCl 2.5% was used as an irrigant. The number of locked, deformed, and separated instruments for the different groups, and within each part of the study was analysed statistically for significance with chi-squared tests. In group 1 only one instrument was deformed in the 150-rpm group and no instruments separated or locked. In the 250-rpm group instrument separation did not occur, however, a high incidence of locking, deformation and separation was noted in the 350-rpm group. In general, instrument sizes 30-15 locked, deformed and separated. Chi-squared statistics showed a significant difference between the 150 and 350 rpm groups but no difference between the 150 and 250 rpm groups with regard to instrument separation. Overall, there was a trend toward a higher incidence of instrument deformation and separation in smaller instruments. Locking and separation occurred during the final passage of the instruments, in the last (tenth) canal in each subgroup. In the second group, neither separation nor deformation and locking occurred during the use of the ProFile instruments, at 150 rpm, and at the different torque values. In the third group, chi-squared analysis demonstrated that significantly more instruments separated with the least experienced operator. Instrument locking, deformation, and separation did not occur with the most experienced operator. Preclinical training in the use of the PRI technique with crown-down at 150 rpm were crucial in avoiding instrument separation and reducing the incidence of instrument locking and deformation.

  6. Boolean linear differential operators on elementary cellular automata

    NASA Astrophysics Data System (ADS)

    Martín Del Rey, Ángel

    2014-12-01

    In this paper, the notion of boolean linear differential operator (BLDO) on elementary cellular automata (ECA) is introduced and some of their more important properties are studied. Special attention is paid to those differential operators whose coefficients are the ECA with rule numbers 90 and 150.

  7. Ultrafast Self-Crystallization of High-External-Quantum-Efficient Fluoride Phosphors for Warm White Light-Emitting Diodes.

    PubMed

    Zhou, Wenli; Fang, Mu-Huai; Lian, Shixun; Liu, Ru-Shi

    2018-05-30

    In this study, we used HF (as good solvent) to dissolve K 2 GeF 6 and K 2 MnF 6 and added ethanol (as poor solvent) to cause ultrafast self-crystallization of K 2 GeF 6 :Mn 4+ crystals, which had an unprecedentedly high external quantum efficiency that reached 73%. By using the red phosphor, we achieved a high-quality warm white light-emitting diode with color-rendering index of R a = 94, R9 = 95, luminous efficacy of 150 lm W -1 , and correlated color temperature at 3652 K. Furthermore, the good-poor solvent strategy can be used to fast synthesize other fluorides.

  8. U.S. EPA, Pesticide Product Label, ORTEX STABILIZED CHLORINE GRANULAR 56, 11/21/1974

    EPA Pesticide Factsheets

    2011-04-14

    ... _'Y .. 'p··se" "I' .150 475 "',e,,, I'" ·:·e'··.,h.: ... lJto:.:t;Ql • ... , el' .~··I·:'i!....uart''''.f IUoo:~ ...

  9. 77 FR 2533 - Boulder Canyon Project

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-18

    ... may also be faxed to (602) 605-2490, attention: Jack Murray. Western will post information about the... charge for electric service and is divided equally between capacity and energy. The annual composite rate is the base charge divided by the annual energy sales. Rate Schedule BCP-F8, Rate Order No. WAPA-150...

  10. 29 CFR 1915.14 - Hot work.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... adjacent to spaces containing flammable gases or liquids, with a flash point below 150 °F (65.6 °C) when...) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Confined and Enclosed Spaces and Other... or on any of the following confined and enclosed spaces and other dangerous atmospheres, boundaries...

  11. 29 CFR 1915.14 - Hot work.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... adjacent to spaces containing flammable gases or liquids, with a flash point below 150 °F (65.6 °C) when...) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Confined and Enclosed Spaces and Other... or on any of the following confined and enclosed spaces and other dangerous atmospheres, boundaries...

  12. 29 CFR 1915.14 - Hot work.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... adjacent to spaces containing flammable gases or liquids, with a flash point below 150 °F (65.6 °C) when...) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Confined and Enclosed Spaces and Other... or on any of the following confined and enclosed spaces and other dangerous atmospheres, boundaries...

  13. 29 CFR 1915.14 - Hot work.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... adjacent to spaces containing flammable gases or liquids, with a flash point below 150 °F (65.6 °C) when...) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Confined and Enclosed Spaces and Other... or on any of the following confined and enclosed spaces and other dangerous atmospheres, boundaries...

  14. 29 CFR 1915.14 - Hot work.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... adjacent to spaces containing flammable gases or liquids, with a flash point below 150 °F (65.6 °C) when...) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Confined and Enclosed Spaces and Other... or on any of the following confined and enclosed spaces and other dangerous atmospheres, boundaries...

  15. 77 FR 64911 - Fluoxastrobin; Pesticide Tolerances

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-24

    ..., liver; hog, fat; hog, meat byproducts; and rice, grain. Arysta LifeScience, North America, LLC... (PP 1F7897) by Arysta LifeScience, North America, LLC, 15401 Weston Pkwy., Suite 150, Cary, NC 27513... Arysta LifeScience, North America LLC, the registrant, which is available in the docket, http:[sol][sol...

  16. Generic Quarantine Radiation Treatment; The Next Steps

    USDA-ARS?s Scientific Manuscript database

    In 2006, USDA-APHIS published a landmark rule providing generic radiation quarantine treatments. The rule approved irradiation doses of 150 Gy for any tephritid fruit fly and 400 Gy for all other insects except the pupa and adult stages of Lepidoptera. The generic radiation treatments apply to all f...

  17. Naval Postgraduate School Scheduling Support System (NPS4)

    DTIC Science & Technology

    1992-03-01

    NPSS ...... .................. 156 2. Final Exam Scheduler .. .......... 159 F. PRESENTATION SYSTEM ... ............. . 160 G. USER INTERFACE... NPSS ...... .................. 185 2. Final Exam Model ... ............ 186 3. The Class Schedulers .. .......... 186 4. Assessment of Problem Model...Information Distribution ....... 150 4.13 NPSS Optimization Process .... ............ . 157 4.14 NPSS Performance ..... ................ . 159 4.15 Department

  18. Greener and Rapid Access to Bio-Active Heterocycles

    EPA Science Inventory

    A new kind of chemical revolution “GREEN CHEMISTRY” is brewing, 150 years after the first one transformed modern life with a host of conveniences. It protects the environment, not by cleaning up, but by inventing new chemistry and new chemical processes that do not pollute. The f...

  19. Formation and removal of PCDD/Fs in a municipal waste incinerator during different operating periods.

    PubMed

    Wang, Hou Chuan; Hwang, Jyh Feng; Chi, Kai Hsien; Chang, Moo Been

    2007-04-01

    The PCDD/F concentrations and removal efficiencies achieved with air pollution control devices (APCDs) during different operating periods (start-up, normal operation, and shut-down) at an existing municipal waste incinerator (MWI) in Taiwan are evaluated via stack sampling and analysis. The MWI investigated is equipped with electrostatic precipitators (EP), wet scrubbers (WS), and selective catalytic reduction system (SCR) as APCDs. The sampling results indicate that the PCDD/F concentrations at the EP inlet during start-up period were 15 times higher than that measured during normal operation period. The PCDD/F concentration observed at shut-down period was close to that measured at normal operation period. The CO concentration was between 400 and 1000 ppm during start-up period, which was about 50 times higher compared with the normal operation. Hence, combustion condition significantly affected the PCDD/F formation concentration during the waste incineration process. In addition, the distributions of the PCDD/F congeners were similar at different operating periods. During the normal operation and shut-down periods, the EP decreases the PCDD/F concentration (based on TEQ) by 18.4-48.6%, while the removal efficiency of PCDD/Fs achieved with SCR system reaches 99.3-99.6%. Nevertheless, the PCDD/F removal efficiency achieved with SCR was only 42% during the 19-h start-up period due to the low SCR operating temperature (195 degrees C).

  20. The Barley Magnesium Chelatase 150-kD Subunit Is Not an Abscisic Acid Receptor1[OA

    PubMed Central

    Müller, André H.; Hansson, Mats

    2009-01-01

    Magnesium chelatase is the first unique enzyme of the chlorophyll biosynthetic pathway. It is composed of three gene products of which the largest is 150 kD. This protein was recently identified as an abscisic acid receptor in Arabidopsis (Arabidopsis thaliana). We have evaluated whether the barley (Hordeum vulgare) magnesium chelatase large subunit, XanF, could be a receptor for the phytohormone. The study involved analysis of recombinant magnesium chelatase protein as well as several induced chlorophyll-deficient magnesium chelatase mutants with defects identified at the gene and protein levels. Abscisic acid had no effect on magnesium chelatase activity and binding to the barley 150-kD protein could not be shown. Magnesium chelatase mutants showed a wild-type response in respect to postgermination growth and stomatal aperture. Our results question the function of the large magnesium chelatase subunit as an abscisic acid receptor. PMID:19176716

  1. Frequency dependence of electrical properties of polyvinylidene fluoride/graphite electrode waste/natural carbon black composite

    NASA Astrophysics Data System (ADS)

    Insiyanda, D. R.; Indayaningsih, N.; Prihandoko, B.; Subhan, A.; Khaerudini, D. S.; Widodo, H.; Destyorini, F.; Chaer, A.

    2018-03-01

    Polyvinylidene fluoride (PVdF) is a semi-crystalline thermoplastic material with remarkably high piezoelectric coefficient and an attractive polymer matrix for micro-composite with superior mechanical and electrical properties. The conductive filler is obtained from Graphite Electrode Waste (GEW) and Natural Carbon Black (NCB). The variation of composite content (%) of PVdF/NCB/GEW were 100/0/0, 95/5/0, 95/0/5, 95/2.5/2.5. This experiment employed dry dispersion method for material mixing. The materials were then moulded using hot press machine with compression parameters of P = 5.5 MPa, T = 150 °C, t = 60 minutes, A = 5×5×(0.2 - 0.4) cm3. The electrical conductivity properties of pure PVdF, as well as PVdF/GEW, PVdF/NCB, and PVdF/NCB/GEW composites were investigated in a frequency range of 100 to 100000 Hz. The PVdF/GEW sample obtained the highest electrical conductivity. It is concluded that GEW and NCB can be incorporated into PVdF as a conductive filler to increase the conductivity of conductive material composite without solvent.

  2. Assessment of the Anthropometric Accommodation Requirements of Non-Pilot Aircrew in the CC-150 Polaris, CP-140 Aurora, CH-149 Cormorant and CC-130 Hercules Aircraft (Exigences Anthropometriques Pour le Personnel Navigant dans le CC-150 Polaris, CP-140 Aurora, CH-149 Cormorant et CC-130 Hercules)

    DTIC Science & Technology

    2008-10-01

    et planification en ressources humaines militaires a aboli la norme de taille minimum des Forces Canadiennes. On a conclu que "les...015; Defence R&D Canada – Toronto; October 2008. Introduction ou contexte : En février 2002, le directeur général – politiques et planification en...arming cables. ....................................................... 6 Figure 4 Reach of full throttle (left) and fire bottle T -handles (right

  3. Operation Duties on the F-15B Research Testbed

    NASA Technical Reports Server (NTRS)

    Truong, Samson S.

    2010-01-01

    This presentation entails what I have done this past summer for my Co-op tour in the Operations Engineering Branch. Activities included supporting the F-15B Research Testbed, supporting the incoming F-15D models, design work, and other operations engineering duties.

  4. Sea Ice Observations from the Winter Weddell Gyre Study - 󈨝

    DTIC Science & Technology

    1991-02-01

    Winter Weddell Gyre Study-󈨝 Debra A. Meese. John W. Govoni. Vladimir Churijn. Borns Ivanov, Victor Komarovskiy. Vasily Shilnikov and Andre Zachek P...A MEESE, JOHN W GOVMN, VLADIMIR CHJURUN. BORIS IVANOV, VICrOR KONIAROVSKIY. VASILY SHILNIKOV AND ANDRE ZACHEK INTRODUCTION 18 September 1989 (day 261...station 24, ,0 f 1 2 150 300 5 JIE1IOBAfl OBOTAIIOBKA OoeaIorpadliuecxanI CTaIIW~lf Pit Itjara: ~ 18 ’= 67𔃿o, ’fP 67-50𔃿 ) 𔃾:S A = iis 5 ~~v BPe.fn

  5. Neutron emission in 19F-induced reactions

    NASA Astrophysics Data System (ADS)

    Acharya, Jaimin; Mukherjee, S.; Chatterjee, A.; Singh, N. L.; Ramachandran, K.; Rout, P. C.; Mahata, K.; Desai, Vishal; Mirgule, E. T.; Suryanarayana, S. V.; Nayak, B. K.; Saxena, A.; Steyn, G. F.

    2018-03-01

    We measured neutron emission spectra for 19F-induced reactions on 181Ta, 89Y, and 51V at beam energies of 130, 140, 145, and 150 MeV. Measurements were made using liquid scintillator detectors at eight angles in the range of 25∘-143∘ using time-of-flight and pulse-shape discrimination. A comparison has been made with alice2014 and pace4 calculations to understand the role of incomplete fusion and pre-equilibrium effects. Global predictions with alice2014 without parameter adjustment gives a fair agreement with the measured data.

  6. Thermal disconnect for high-temperature batteries

    DOEpatents

    Jungst, Rudolph George; Armijo, James Rudolph; Frear, Darrel Richard

    2000-01-01

    A new type of high temperature thermal disconnect has been developed to protect electrical and mechanical equipment from damage caused by operation at extreme temperatures. These thermal disconnects allow continuous operation at temperatures ranging from 250.degree. C. to 450.degree. C., while rapidly terminating operation at temperatures 50.degree. C. to 150.degree. C. higher than the continuous operating temperature.

  7. 36 CFR Appendix A to Part 1191 - Table Of Contents

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Protruding Objects 205 Operable Parts 206 Accessible Routes 207 Accessible Means of Egress 208 Parking Spaces..., Kitchenettes, and Sinks 213 Toilet Facilities and Bathing Facilities 214 Washing Machines and Clothes Dryers... F205 Operable Parts F206 Accessible Routes F207 Accessible Means of Egress F208 Parking Spaces F209...

  8. LWC and Temperature Effects on Ice Accretion Formation on Swept Wings at Glaze Ice Conditions

    NASA Technical Reports Server (NTRS)

    Vargas, Mario; Reshotko, Eli

    2000-01-01

    An experiment was conducted to study the effect of liquid water content and temperature on the critical distance in ice accretion formation on swept wings at glaze ice conditions. The critical distance is defined as the distance from the attachment line to tile beginning of the zone where roughness elements develop into glaze ice feathers. A baseline case of 150 mph, 25 F, 0.75 g/cu m. Cloud Liquid Water Content (LWC) and 20 micrometers in Water Droplet Median Volume Diameter (MVD) was chosen. Icing runs were performed on a NACA 0012 swept wing tip at 150 mph and MVD of 20 micrometers for liquid water contents of 0.5 g/cu m, 0.75 g/cu m, and 1.0 g/cu m, and for total temperatures of 20 F, 25 F and 30 F. At each tunnel condition, the sweep angle was changed from 0 deg to 45 deg in 5 deg increments. Casting data, ice shape tracings, and close-up photographic data were obtained. The results showed that decreasing the LWC to 0.5 g/cu m decreases the value of the critical distance at a given sweep angle compared to the baseline case, and starts the formation of complete scallops at 30 sweep angle. Increasing the LWC to 1.0 g/cu m increases the value of the critical distance compared to the baseline case, the critical distance remains always above 0 millimeters and complete scallops are not formed. Decreasing the total temperature to 20 F decreases the critical distance with respect to the baseline case and formation of complete scallops begins at 25 deg sweep angle. When the total temperature is increased to 30 F, bumps covered with roughness elements appear on the ice accretion at 25 deg and 30 deg sweep angles, large ice structures appear at 35 deg and 40 deg sweep angles, and complete scallops are formed at 45 deg sweep angle.

  9. Assessment of ventilatory thresholds during graded and maximal exercise test using time varying analysis of respiratory sinus arrhythmia.

    PubMed

    Blain, G; Meste, O; Bouchard, T; Bermon, S

    2005-07-01

    To test whether ventilatory thresholds, measured during an exercise test, could be assessed using time varying analysis of respiratory sinus arrhythmia frequency (f(RSA)). Fourteen sedentary subjects and 12 endurance athletes performed a graded and maximal exercise test on a cycle ergometer: initial load 75 W (sedentary subjects) and 150 W (athletes), increments 37.5 W/2 min. f(RSA) was extracted from heart period series using an evolutive model. First (T(V1)) and second (T(V2)) ventilatory thresholds were determined from the time course curves of ventilation and ventilatory equivalents for O(2) and CO(2). f(RSA) was accurately extracted from all recordings and positively correlated to respiratory frequency (r = 0.96 (0.03), p<0.01). In 21 of the 26 subjects, two successive non-linear increases were determined in f(RSA), defining the first (T(RSA1)) and second (T(RSA2)) f(RSA) thresholds. When expressed as a function of power, T(RSA1) and T(RSA2) were not significantly different from and closely linked to T(V1) (r = 0.99, p<0.001) and T(V2) (r = 0.99, p<0.001), respectively. In the five remaining subjects, only one non-linear increase was observed close to T(V2). Significant differences (p<0.04) were found between athlete and sedentary groups when T(RSA1) and T(RSA2) were expressed in terms of absolute and relative power and percentage of maximal aerobic power. In the sedentary group, T(RSA1) and T(RSA2) were 150.3 (18.7) W and 198.3 (28.8) W, respectively, whereas in the athlete group T(RSA1) and T(RSA2) were 247.3 (32.8) W and 316.0 (28.8) W, respectively. Dynamic analysis of f(RSA) provides a useful tool for identifying ventilatory thresholds during graded and maximal exercise test in sedentary subjects and athletes.

  10. Assessment of ventilatory thresholds during graded and maximal exercise test using time varying analysis of respiratory sinus arrhythmia

    PubMed Central

    Blain, G; Meste, O; Bouchard, T; Bermon, S; Segura, R.

    2005-01-01

    Objective: To test whether ventilatory thresholds, measured during an exercise test, could be assessed using time varying analysis of respiratory sinus arrhythmia frequency (fRSA). Methods: Fourteen sedentary subjects and 12 endurance athletes performed a graded and maximal exercise test on a cycle ergometer: initial load 75 W (sedentary subjects) and 150 W (athletes), increments 37.5 W/2 min. fRSA was extracted from heart period series using an evolutive model. First (TV1) and second (TV2) ventilatory thresholds were determined from the time course curves of ventilation and ventilatory equivalents for O2 and CO2. Results: fRSA was accurately extracted from all recordings and positively correlated to respiratory frequency (r = 0.96 (0.03), p<0.01). In 21 of the 26 subjects, two successive non-linear increases were determined in fRSA, defining the first (TRSA1) and second (TRSA2) fRSA thresholds. When expressed as a function of power, TRSA1 and TRSA2 were not significantly different from and closely linked to TV1 (r = 0.99, p<0.001) and TV2 (r = 0.99, p<0.001), respectively. In the five remaining subjects, only one non-linear increase was observed close to TV2. Significant differences (p<0.04) were found between athlete and sedentary groups when TRSA1 and TRSA2 were expressed in terms of absolute and relative power and percentage of maximal aerobic power. In the sedentary group, TRSA1 and TRSA2 were 150.3 (18.7) W and 198.3 (28.8) W, respectively, whereas in the athlete group TRSA1 and TRSA2 were 247.3 (32.8) W and 316.0 (28.8) W, respectively. Conclusions: Dynamic analysis of fRSA provides a useful tool for identifying ventilatory thresholds during graded and maximal exercise test in sedentary subjects and athletes. PMID:15976169

  11. 23 CFR 661.37 - What are the funding limitations on individual IRRBP projects?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... ENGINEERING AND TRAFFIC OPERATIONS INDIAN RESERVATION ROAD BRIDGE PROGRAM § 661.37 What are the funding..., with a $150,000 maximum limit for PE. (b) An IRRBP eligible non-BIA owned IRR bridge is eligible for up to 80 percent IRRBP funding, with a $150,000 maximum limit for PE and $1,000,000 maximum limit for...

  12. 23 CFR 661.37 - What are the funding limitations on individual IRRBP projects?

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... ENGINEERING AND TRAFFIC OPERATIONS INDIAN RESERVATION ROAD BRIDGE PROGRAM § 661.37 What are the funding..., with a $150,000 maximum limit for PE. (b) An IRRBP eligible non-BIA owned IRR bridge is eligible for up to 80 percent IRRBP funding, with a $150,000 maximum limit for PE and $1,000,000 maximum limit for...

  13. 23 CFR 661.37 - What are the funding limitations on individual IRRBP projects?

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... ENGINEERING AND TRAFFIC OPERATIONS INDIAN RESERVATION ROAD BRIDGE PROGRAM § 661.37 What are the funding..., with a $150,000 maximum limit for PE. (b) An IRRBP eligible non-BIA owned IRR bridge is eligible for up to 80 percent IRRBP funding, with a $150,000 maximum limit for PE and $1,000,000 maximum limit for...

  14. 23 CFR 661.37 - What are the funding limitations on individual IRRBP projects?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... ENGINEERING AND TRAFFIC OPERATIONS INDIAN RESERVATION ROAD BRIDGE PROGRAM § 661.37 What are the funding..., with a $150,000 maximum limit for PE. (b) An IRRBP eligible non-BIA owned IRR bridge is eligible for up to 80 percent IRRBP funding, with a $150,000 maximum limit for PE and $1,000,000 maximum limit for...

  15. 23 CFR 661.37 - What are the funding limitations on individual IRRBP projects?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... ENGINEERING AND TRAFFIC OPERATIONS INDIAN RESERVATION ROAD BRIDGE PROGRAM § 661.37 What are the funding..., with a $150,000 maximum limit for PE. (b) An IRRBP eligible non-BIA owned IRR bridge is eligible for up to 80 percent IRRBP funding, with a $150,000 maximum limit for PE and $1,000,000 maximum limit for...

  16. 33 CFR 150.905 - Why are safety zones, no anchoring areas, and areas to be avoided established?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Why are safety zones, no...: OPERATIONS Safety Zones, No Anchoring Areas, and Areas To Be Avoided § 150.905 Why are safety zones, no anchoring areas, and areas to be avoided established? (a) Safety zones, no anchoring areas (NAAs) and areas...

  17. Characterization and Performance of a Kilo-TES Sub-Array for ACTPol

    NASA Technical Reports Server (NTRS)

    Grace, E. A.; Beall, J.; Cho, H. M.; Devlin, M. J.; Fox, A.; Hilton, G.; Hubmayr, J.; Irwin, K.; Klein, J.; Li, D.; hide

    2014-01-01

    ACTPol is a polarization-sensitive receiver upgrade to the Atacama CosmologyTelescope (ACT) which will make millimeterwavelength measurements of the small-scale polarization anisotropies of the cosmic microwave background to investigate the properties of inflation, dark energy, dark matter, and neutrinos in the early Universe. ACTPol will employ three arrays of transition edge sensor (TES) bolometer detectors. The detectors, with a target transition temperature of 150 mK, will be operated at a bath temperature of 100 mK provided by a dilution refrigerator. One array operating at a central frequency of 150 GHz and consisting of 1024 TESes achieved first light at the ACT site in July 2013. We anticipate fielding the remainder of the focal plane, consisting of a second 150 GHz array and a multi-chroic array sensitive to 90 and 150 GHz, at the end of the 2013 observing season. In these proceedings, we present characterization of key detector parameters from measurements performed on the first array both in the lab and during initial field testing. We comment on the design goals, measurements, and uniformity of the detector transition temperatures, saturation powers, and thermal conductivities while detailing measurement methods and results for the detector optical efficiencies and time constants.

  18. [Midterm follow-up results on Asian femoral intramedullary nail for the treatment of segmental and comminuted femoral fractures].

    PubMed

    Li, Lang; Gao, Feng; Huang, Qi; Li, Qiang; Xie, Lin; Zhang, Bin

    2016-06-01

    To investigate midterm follow-up results on Asian femoral intramedullary nail in treating segmental and comminuted femoral fractures. Between June 2011 and October 2012,16 patients with segmental and comminuted femoral fractures were treated with minimally invasive reset and Asian femoral intramedullary nail under extension table. Among them, there were 10 males and 6 females aged from 21 to 49 years old with an average of 34.5 years old; the time from injury to operation ranged from 3 to 24 d with an average of 9.1 d. There were 6 cases were type C1,2 cases were type C2 and 8 cases were type C3 according to AO classification. X-ray of femoral segment at 3,6 and 12 months after operation were applied for evaluating fracture healing. Harris score of hip joint and HSS score of knee joint were used to evaluate postoperative function. All patients were followed up from 24 to 36 months with an average of 28.4 months. Operative time was from 88 to 112 min with an average of 90.7 min; blood loss ranged from 150 to 200 ml with an average of 188.75 ml; the time of fracture healing was from 5 to 9 months with an average of 5.4 months. All incision were healed at stage I. No loosening, breakage of internal fixation and displacement of fracture were occurred. There were no significant differences in Harris score of hip joint at 3, 6 and 12 months after operation (F = 0.07, P = 0.893 > 0.05), 10 cases obtained excellent results, 5 good and 1 moderate. There was no obvious meaning in HSS score of knee joint (F = 0.08,P = 0.876 > 0.05), 9 cases obtained excellent results, 6 good and 1 poor. Asian femoral intramedullary nail could treat segmental and comminuted femoral fractures by using variety of less invasive ways,which has advantages of less trauma, quick recovery of function and satisfied midterm following-up results. But long term following-up effects remains to be seen.

  19. Screening of high temperature adhesives for large area bonding

    NASA Technical Reports Server (NTRS)

    Stenersen, A. A.; Wykes, D. H.

    1980-01-01

    High temperature-resistant adhesive systems were screened for processability, mechanical and physical properties, operational capability at 589 K (600 F), and the ability to produce large area bonds of high quality in fabricating Space Shuttle components. The adhesives consisted primarily of polyimide systems, including FM34B-18, NR-150B2 (DuPont), PMR-15, LARC-13, LARC-160, Thermid 600, and AI-1130L (AMOCA). The processing studies included preparation of polyimide resins, fabrication of film adhesives, development of lay-up and cure procedures, fabrication of honeycomb sandwich panels, and fabrication of mid-plane bonded panels in joints up to 30.5 cm (12 in.) wide. The screening program included tests for tack and drape properties, reticulation and filleting characteristics, ability to produce void-free or low porosity bonds in mid-plane bonded panels, out-time stability, lap shear strength, climbing drum peel strength, and glass transition temperature (Tg). This paper describes the processing methods developed and the test results.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilke, Rudeger H. T.; Baker, Amanda; Brown-Shaklee, Harlan

    Here, alkali-free glasses, which exhibit high energy storage densities (~35 J/cc), present a unique opportunity to couple high temperature stability with high breakdown strength, and thus provide an avenue for capacitor applications with stringent temperature and power requirements. Realizing the potential of these materials in kilovolt class capacitors with >1 J/cc recoverable energy density requires novel packaging strategies that incorporate these extremely fragile dielectrics. In this paper, we demonstrate the feasibility of fabricating wound capacitors using 50-μm-thick glass. Two capacitors were fabricated from 2.8-m-long ribbons of thin (50 μm) glass wound into 125-140-mm-diameter spools. The capacitors exhibit a capacitance ofmore » 70-75 nF with loss tangents below 1%. The wound capacitors can operate up to 1 kV and show excellent temperature stability to 150 °C. By improving the end terminations, the self-resonance can be shifted to above 1 MHz, indicating that these materials may be useful for pulsed power applications with microsecond discharge times.« less

  1. Passive Q-switching of a Tm:YLF laser with a Co2+ doped silver halide saturable absorber

    NASA Astrophysics Data System (ADS)

    Hecht, Harel; Burshtein, Zeev; Katzir, Abraham; Noach, Salman; Sokol, Maxim; Frumker, Eugene; Galun, Ehud; Ishaaya, Amiel A.

    2017-02-01

    We report a successful passive Q-switching of a Tm:YLF laser operating at λ = 1.9 μm, using a Co2+:AgCl0.5Br0.5 saturable absorber. Approximately 200-ns long, 150 μJ pulses were obtained. Increase in pump energy resulted in repetitive pulsing, with a repetition rate approximately proportional to the pump pulse energy. Room-temperature optical transmission saturation curves measured in ∼1-mm thick Co2+:AgCl0.5Br0.5 plates yielded a ground state absorption cross section σgs =(7.8 ± 0.5) ×10-18 cm2 , and an excited state absorption cross section σes =(3.3 ± 0.3) ×10-18 cm2 , at λ = 1.9 μm. The lifetime of the A2(4F) second excited-state of the octahedral O symmetry was τ∗ =(0.6 ± 0.06) ns .

  2. Singlet vs Nonsinglet Perturbative Renormalization factors of Staggered Fermion Bilinears

    NASA Astrophysics Data System (ADS)

    Panagopoulos, Haralambos; Spanoudes, Gregoris

    2018-03-01

    In this paper we present the perturbative computation of the difference between the renormalization factors of flavor singlet (Σfψ¯fΓψf', f : flavor index) and nonsinglet (ψ¯f1Γψf2,f1 ≠ f2) bilinear quark operators (where Γ = 𝟙, γ5, γ µ, γ5 γ µ, γ5 σµv on the lattice. The computation is performed to two loops and to lowest order in the lattice spacing, using Symanzik improved gluons and staggered fermions with twice stout-smeared links. The stout smearing procedure is also applied to the definition of bilinear operators. A significant part of this work is the development of a method for treating some new peculiar divergent integrals stemming from the staggered formalism. Our results can be combined with precise simulation results for the renormalization factors of the nonsinglet operators, in order to obtain an estimate of the renormalization factors for the singlet operators. The results have been published in Physical Review D [1].

  3. Influence of F0 and Sequence Length of Audio and Electroglottographic Signals on Perturbation Measures for Voice Assessment.

    PubMed

    Hohm, Julian; Döllinger, Michael; Bohr, Christopher; Kniesburges, Stefan; Ziethe, Anke

    2015-07-01

    Within the functional assessment of voice disorders, an objective analysis of measured parameters from audio, electroglottographic (EGG), or visual signals is desired. In a typical clinical situation, reliable objective analysis is not always possible due to missing standardization and unknown stability of the clinical parameters. The aim of this study was to investigate the robustness/stability of measured clinical parameters of the audio and EGG signals in a typical clinical setting to ensure a reliable objective analysis. In particular, the influence of F0 and of the sequence length on several definitions of jitter and shimmer will be analyzed. Seventy-four young healthy women produced a sustained vowel /a/ and an upward triad with abrupt changeovers. Different sequence lengths (100, 150, 500, and 1000 ms) of sustained phonation and triads (100 and 150 ms) were extracted from the audio and EGG signals. In total, six variations of jitter and four variations of shimmer parameters were analyzed. Jitter%, Jitter11p, and JitterPPQ of the audio signal as well as Jittermean, Shimmer, and Shimmer11p of the EGG signal are unaffected by both sequence length and F0. Influence of F0 and sequence length on several perturbation measures of the audio and EGG signals was identified. For an objective clinical voice assessment, unaffected definitions of jitter and shimmer should be preferred and applied to enable comparability between different recordings, examinations, and studies. Copyright © 2015 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  4. 7 CFR 58.218 - Surge tanks.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 3 2012-01-01 2012-01-01 false Surge tanks. 58.218 Section 58.218 Agriculture....218 Surge tanks. If surge tanks are used for hot milk, and temperatures of product including foam being held in the surge tank during processing, is not maintained at a minimum of 150 °F, then two or...

  5. 7 CFR 58.218 - Surge tanks.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Surge tanks. 58.218 Section 58.218 Agriculture....218 Surge tanks. If surge tanks are used for hot milk, and temperatures of product including foam being held in the surge tank during processing, is not maintained at a minimum of 150 °F, then two or...

  6. 7 CFR 58.218 - Surge tanks.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Surge tanks. 58.218 Section 58.218 Agriculture....218 Surge tanks. If surge tanks are used for hot milk, and temperatures of product including foam being held in the surge tank during processing, is not maintained at a minimum of 150 °F, then two or...

  7. 7 CFR 58.218 - Surge tanks.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 3 2013-01-01 2013-01-01 false Surge tanks. 58.218 Section 58.218 Agriculture....218 Surge tanks. If surge tanks are used for hot milk, and temperatures of product including foam being held in the surge tank during processing, is not maintained at a minimum of 150 °F, then two or...

  8. 7 CFR 58.218 - Surge tanks.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 3 2014-01-01 2014-01-01 false Surge tanks. 58.218 Section 58.218 Agriculture....218 Surge tanks. If surge tanks are used for hot milk, and temperatures of product including foam being held in the surge tank during processing, is not maintained at a minimum of 150 °F, then two or...

  9. 42 CFR 483.150 - Statutory basis; Deemed meeting or waiver of requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... CARE FACILITIES Requirements That Must Be Met by States and State Agencies: Nurse Aide Training and... 1919(f)(2) of the Act, which establish standards for training nurse-aides and for evaluating their competency. (b) Deemed meeting of requirements. A nurse aide is deemed to satisfy the requirement of...

  10. 78 FR 13754 - Notice of Receipt of Petition for Decision That Nonconforming 2004 Ford F-150 Crew Cab Trucks...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-28

    ..., self-addressed postcard with the comments. Note that all comments received will be posted without... Components, 207 Seating Systems, 208 Occupant Crash Protection, 209 Seat Belt Assemblies, 210 Seat Belt Assembly Anchorages, 212 Windshield Mounting, 214 Side Impact Protection, 216 Roof Crush Resistance, 219...

  11. Film Catalog. John F. Kennedy Space Center. 1987.

    ERIC Educational Resources Information Center

    National Aeronautics and Space Administration, Washington, DC.

    Teachers from the United States and several other countries have access to the film library system of the National Aeronautics and Space Administration (NASA). This catalog contains the titles and abstracts for over 150 films that are available from NASA on topics regarding space flight, meteorology, astronomy, NASA programs, satellites, research,…

  12. Physics of High-Temperature Air. Part. 2. Applications

    DTIC Science & Technology

    1990-08-01

    water-soluble material such as sea salt, and biotic particles such as bacteria and fine plant debris, as well as water and ice particles. Table 7.3...150 180 1-F .41.W-32 4 o Figure 7.5. Scattering from Distributions of Water Droplets (of mean radius 4 gmo ) at Different Wavelengths. (Source: Bauer

  13. 47 CFR 90.1331 - Restrictions on the operation of base and fixed stations.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... any grandfathered satellite earth station operating in the 3650-3700 MHz band. The coordinates of... located within 150 km of a grandfathered satellite earth station provided that the licensee of the satellite earth station and the 3650-3700 MHz licensee mutually agree on such operation. (3) Any...

  14. 47 CFR 90.1331 - Restrictions on the operation of base and fixed stations.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... any grandfathered satellite earth station operating in the 3650-3700 MHz band. The coordinates of... located within 150 km of a grandfathered satellite earth station provided that the licensee of the satellite earth station and the 3650-3700 MHz licensee mutually agree on such operation. (3) Any...

  15. 47 CFR 90.1331 - Restrictions on the operation of base and fixed stations.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... any grandfathered satellite earth station operating in the 3650-3700 MHz band. The coordinates of... located within 150 km of a grandfathered satellite earth station provided that the licensee of the satellite earth station and the 3650-3700 MHz licensee mutually agree on such operation. (3) Any...

  16. 47 CFR 90.1331 - Restrictions on the operation of base and fixed stations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... any grandfathered satellite earth station operating in the 3650-3700 MHz band. The coordinates of... located within 150 km of a grandfathered satellite earth station provided that the licensee of the satellite earth station and the 3650-3700 MHz licensee mutually agree on such operation. (3) Any...

  17. 47 CFR 90.1331 - Restrictions on the operation of base and fixed stations.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... any grandfathered satellite earth station operating in the 3650-3700 MHz band. The coordinates of... located within 150 km of a grandfathered satellite earth station provided that the licensee of the satellite earth station and the 3650-3700 MHz licensee mutually agree on such operation. (3) Any...

  18. 46 CFR 178.330 - Simplified stability proof test.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...-meters (foot-pounds); P = wind pressure of: (1) 36.6 kilograms/square meter (7.5 pounds/square foot) for operation on protected waters; (2) 48.8 kilogram/square meter (10.0 pounds/square foot) for operation on partially protected waters; or (3) 73.3 kilograms/square meter (15.0 pounds/square foot) for operation on...

  19. Department of Defense Operation and Financial Support for Military Museums

    DTIC Science & Technology

    2009-01-01

    t a r y M u s e u m s Service Museums DoD Appropriations Total Federal Other Sources Grand Total Operation and Maintenance Military... Operation and Maintenance Military Personnel DoD Appropriations F Y 2 0 0 9 F u n d i n g f o r M i l i t a r y M u s e u m s Service...museum operations , to include developing the museum’s operational budget, accessioning and deaccessioning artifacts,

  20. The Ada (Trade Name) Compiler Validation Capability Implementers’ Guide. Version 1,

    DTIC Science & Technology

    1986-12-01

    f ADA20.ISI.EDU using the same format as for comments on the RM: Isection x.y.z(pp) Commenter’s Name YY-MM-". Iversion v Itopic brief description of...Operations (Integer) .............. 4-63 4.5.2.e Reltionl and Membership Operations (FixedtFloat) ........... 4-64 4.5.2. f Relational and Membership...Absolute Value Operator (PIxe&M ) .................. 4 4.5.6. Scalar Negation Operator 4.9 " 4.5.6. f Array Negation Operator

  1. Identification of residues important for the activity of aldehyde-deformylating oxygenase through investigation into the structure-activity relationship.

    PubMed

    Wang, Qing; Bao, Luyao; Jia, Chenjun; Li, Mei; Li, Jian-Jun; Lu, Xuefeng

    2017-03-16

    Aldehyde-deformylating oxygenase (ADO) is a key enzyme involved in the biosynthetic pathway of fatty alk(a/e)nes in cyanobacteria. However, cADO (cyanobacterial ADO) showed extreme low activity with the k cat value below 1 min -1 , which would limit its application in biofuel production. To identify the activity related key residues of cADO is urgently required. The amino acid residues which might affect cADO activity were identified based on the crystal structures and sequence alignment of cADOs, including the residues close to the di-iron center (Tyr39, Arg62, Gln110, Tyr122, Asp143 of cADO-1593), the protein surface (Trp 178 of cADO-1593), and those involved in two important hydrogen bonds (Gln49, Asn123 of cADO-1593, and Asp49, Asn123 of cADO-sll0208) and in the oligopeptide whose conformation changed in the absence of the di-iron center (Leu146, Asn149, Phe150 of cADO-1593, and Thr146, Leu148, Tyr150 of cADO-sll0208). The variants of cADO-1593 from Synechococcus elongatus PCC7942 and cADO-sll0208 from Synechocystis sp. PCC6803 were constructed, overexpressed, purified and kinetically characterized. The k cat values of L146T, Q49H/N123H/F150Y and W178R of cADO-1593 and L148R of cADO-sll0208 were increased by more than two-fold, whereas that of R62A dropped by 91.1%. N123H, Y39F and D143A of cADO-1593, and Y150F of cADO-sll0208 reduced activities by ≤ 20%. Some important amino acids, which exerted some effects on cADO activity, were identified. Several enzyme variants exhibited greatly reduced activity, while the k cat values of several mutants are more than two-fold higher than the wild type. This study presents the report on the relationship between amino acid residues and enzyme activity of cADOs, and the information will provide a guide for enhancement of cADO activity through protein engineering.

  2. Assessment of the Geothermal Potential Within the BPA Marketing Area.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lund, John W.; Allen, Eliot D.

    1980-07-01

    The potential of geothermal energy is estimated that can be used for direct heat applications and electrical power generation within the Bonneville Power Administration (BPA) marketing area. The BPA marketing area includes three principal states of Oregon, Washington, and Idaho and portions of California, Montana, Wyoming, Nevada, and Utah bordering on these three states. This area covers approximately 384,000 square miles and has an estimated population of 6,760,000. The total electrical geothermal potential within this marketing area is 4077 MW/sub e/ from hydrothermal resources and 16,000 MW/sub e/ from igneous systems, whereas the total thermal (wellhead) potential is 16.15 xmore » 10/sup 15/ Btu/y. Approximately 200 geothermal resource sites were initially identified within the BPA marketing area. This number was then reduced to about 100 sites thought to be the most promising for development by the year 2000. These 100 sites, due to load area overlap, were grouped into 53 composite sites; 21-3/4 within BPA preference customer areas and 31-1/4 within nonpreference customer areas. The geothermal resource potential was then estimated for high-temperature (> 302/sup 0/F = 150/sup 0/C), intermediate-temperature (194 to 302/sup 0/F = 90 to 150/sup 0/C), and low-temperature (< 194/sup 0/F = 90/sup 0/C) resources.« less

  3. Investigation of heating of 150 kV underground cable line for various conditions of laying

    NASA Astrophysics Data System (ADS)

    Kukharchuk, I. B.; Kazakov, A. V.; Trufanova, N. M.

    2018-03-01

    The work is devoted to study of temperature operation of a 150 kV underground cable line with XLPE insulation. The stationary thermal conditions were calculated. The influence of outer boundary radius selection on the temperature distribution was analyzed. The limiting value of the filling mixture thermal conductivity was found, which provides an acceptable temperature of the cable.

  4. Fluid Dynamic Analysis of Hand-Pump Infuser and UROMAT Endoscopic Automatic System for Irrigation Through a Flexible Ureteroscope.

    PubMed

    Lama, Daniel J; Owyong, Michael; Parkhomenko, Egor; Patel, Roshan M; Landman, Jaime; Clayman, Ralph V

    2018-05-01

    To evaluate the flow characteristics produced by a manual and automated-pump irrigation system connected to a flexible ureteroscope. An in vitro analysis of a manual hand-pump infuser (HP) and the UROMAT Endoscopic Automatic System for Irrigation ® (E.A.S.I.) pump was performed. Standard irrigation tubing was used to connect a three-way valve to a flexible ureteroscope, the irrigation system, and a digital manometer. Flow rate and irrigation pressure measurements were recorded over a 15-minute period using pressure settings of 150 and 200 mm Hg for both irrigation pump systems. Once the HP was inflated to the initial pressure, it was not reinflated over the course of the trial. Data were collected with the working channel unoccupied and with placement of a 200 μm (0.6F) holmium laser fiber, 1.7F nitinol stone retrieval basket, or 2.67F guidewire. The difference in pressure measured at the site of inflow of irrigation to the ureteroscope was significantly greater using the HP compared to the E.A.S.I. pump at pressure settings of 150 mm Hg with and without the use of ureteroscopic instrumentation (p < 0.001), and at 200 mm Hg with instrumentation in the working channel (p < 0.01). There was no significant difference in the flow rate of irrigation through the open-channel ureteroscope over the course of 5 minutes between the two pump systems. The flow rates of irrigation produced by the HP and the E.A.S.I. pump are similar at pressures of 150 and 200 mm Hg irrespective of the occupancy of a ureteroscope's working channel during the first 5-minutes of irrigation. Irrigation pressure at the entry site of the ureteroscope is subject to significant variability with use of the HP compared to the E.A.S.I. pump irrigation system.

  5. 40 CFR 63.1512 - Performance test/compliance demonstration requirements and procedures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... operator must conduct a performance test to measure THC and D/F emissions at the outlet of the control.../decoating kiln. The owner or operator must conduct performance tests to measure emissions of THC, D/F, HCl... operating temperature of each afterburner every 15 minutes during the THC and D/F performance tests; (ii...

  6. 40 CFR 63.1512 - Performance test/compliance demonstration requirements and procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... operator must conduct a performance test to measure THC and D/F emissions at the outlet of the control.../decoating kiln. The owner or operator must conduct performance tests to measure emissions of THC, D/F, HCl... operating temperature of each afterburner every 15 minutes during the THC and D/F performance tests; (ii...

  7. Water pulsejet research. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Payne, P.R.; Brown, R.G.; Brown, J.P.

    1979-04-01

    The steam water pulsejet (SWPJ) - a modern derivative of the Piot-McHugh putt-putt toy boat - is discussed. Studies have revealed that, like its air-breathing relatives, one type of SWPJ is a type of wave engine. This report first reviews the background literature and then summarizes recent improvements in our understanding of the engine's operation. An appendix attempts to show the various physical processes of the wave engine version in a quantifiable way. At low temperatures, the ideal cycle efficiency of this version is almost identical with the Carnot limit, diverging above a ..delta..T approx. = 150/sup 0/F. Maximum idealmore » cycle efficiency occurs in the 500/sup 0/-600/sup 0/F range, and is 30%-40%. In addition to the two wave engines (simple wave engine, and a wave engine with a water trap), the boundary layer boiler was developed which may but need not involve wave effects and the Piot-cycle. In the latter engine, some water is flashed rapidly to steam in a separate (but connected) compartment and reaches high pressure before the water column (because of its inertia) has moved appreciably. Ideal efficiencies for this cycle can be of the order of 10%-20%. Although a great deal of knowledge was gained, the present program was unsuccessful in applying the newly discovered cycles to build reliable and efficient solar powered pumps.« less

  8. Sodankylä ionospheric tomography dataset 2003-2014

    NASA Astrophysics Data System (ADS)

    Norberg, J.; Roininen, L.; Kero, A.; Raita, T.; Ulich, T.; Markkanen, M.; Juusola, L.; Kauristie, K.

    2015-12-01

    Sodankylä Geophysical Observatory has been operating a tomographic receiver network and collecting the produced data since 2003. The collected dataset consists of phase difference curves measured from Russian COSMOS dual-frequency (150/400 MHz) low-Earth-orbit satellite signals, and tomographic electron density reconstructions obtained from these measurements. In this study vertical total electron content (VTEC) values are integrated from the reconstructed electron densities to make a qualitative and quantitative analysis to validate the long-term performance of the tomographic system. During the observation period, 2003-2014, there were three-to-five operational stations at the Fenno-Scandinavian sector. Altogether the analysis consists of around 66 000 overflights, but to ensure the quality of the reconstructions, the examination is limited to cases with descending (north to south) overflights and maximum elevation over 60°. These constraints limit the number of overflights to around 10 000. Based on this dataset, one solar cycle of ionospheric vertical total electron content estimates is constructed. The measurements are compared against International Reference Ionosphere IRI-2012 model, F10.7 solar flux index and sunspot number data. Qualitatively the tomographic VTEC estimate corresponds to reference data very well, but the IRI-2012 model are on average 40 % higher of that of the tomographic results.

  9. Camera/Photometer Results

    NASA Astrophysics Data System (ADS)

    Clifton, K. S.; Owens, J. K.

    1983-04-01

    Efforts continue regarding the analysis of particulate contamination recorded by the Camera/Photometers on STS-2. These systems were constructed by Epsilon Laboratories, Inc. and consisted of two 16-mm photographic cameras, using Kodak Double X film, Type 7222, to make stereoscopic observations of contaminant particles and background. Each was housed within a pressurized canister and operated automatically throughout the mission, making simultaneous exposures on a continuous basis every 150 sec. The cameras were equipped with 18-mm f/0.9 lenses and subtended overlapping 20° fields-of-view. An integrating photometer was used to inhibit the exposure sequences during periods of excessive illumination and to terminate the exposures at preset light levels. During the exposures, a camera shutter operated in a chopping mode in order to isolate the movement of particles for velocity determinations. Calculations based on the preflight film calibration indicate that particles as small as 25 μm can be detected from ideal observing conditions. Current emphasis is placed on the digitization of the photographic data frames and the determination of particle distances, sizes, and velocities. It has been concluded that background bright-ness measurements cannot be established with any reliability on the STS-2 mission, due to the preponderance of Earth-directed attitudes and the incidence of light reflected from nearby surfaces.

  10. Cost Estimation for Surface Navy Investment in Arctic-capable Platform to Maintain National Security Interests

    DTIC Science & Technology

    2014-12-01

    Approx) A N OVA R~gresslon R esidual Total d.f. ss 1 . 0 .00018 1. 0 .00518 2. 0 .00536 Coefficients Standard Error Intercept 0.04 234 0...150.3230 + 27.9237 • "Mission" Rating (1-10) AN OVA Regression Residual To Cal d.f. 1 . 1 . 2 . ss 2,469.15829 1,630.59238 4 .099.75068...per Foot ($M) =· 1.8590 + 0.0091 • Length (ft) AN OVA d . fc ss Regres sion 1 . 4.22352 Residual 4 . 7.26194 Total 5 . 11.48546 Coefficients

  11. Monte Carlo Simulation of Seismic Location Errors for Moving Vehicles

    DTIC Science & Technology

    2001-10-04

    Smart Weapons Test Range 9/14/200 Four wheel Drive; File 14, Aberdeen, MD, Site 1 June 11, 1996, 10c runs, Piston Tank ; 10:18 34:42 53:55 58:64...72:79 92:97 105:118 % file vector Ft. Greely, AK, Site 1 1/27/1997, , Piston Tank ; 34:42 53:64 % file vector Ft. Greely, AK, Site 2...Dec 11, 1997 ; File 56, , Piston Tank Aberdeen, MD, Site 2 10/28/97 File84; File 56 200 400 600 800 1000 1200 -160 -150 -140 -130 -120 fL fH

  12. Akt Phosphorylation and PI (3, 4, 5) P3 Binding Coordinately Inhibit the Tumor Suppressive Activity of Merlin

    DTIC Science & Technology

    2010-02-01

    C-terminal F-actin binding site. Recent work using either unphosphorylated or T558 phosphorylated moesin purified from platelets revealed a dual...Pestonjamasp K, Luna EJ, & Furthmayr H (1999) Regulation of F-actin binding to platelet moesin in vitro by both phosphorylation of threonine 558 and... Lysate IB: anti-GFP M.W.(kDa) 100 75 50 37 150 em pt y ve ct or G FP -s um o1 IB: anti-GFP CB IB: anti-myc myc-merlin em pt y ve ct or G FP -s um o1 myc

  13. Magnetic Resonance Arterial Spin Tagging for Non-Invasive Pharmacokinetic Analysis of Breast Cancer

    DTIC Science & Technology

    2000-10-01

    sequence software that we had developed for this project. In addition, we revised the pulse sequences to utilize the high performance gradients (40 mT/ m ...peak, 150 mT/ m /ms rise) of the system. We believe these revised sequences will provide better arterial spin tagged data for perfusion measurement. All...U.... ...... ... -- v p I _1 i-:F~ ----- ! - .Ag Jig. H aI .. M e fI6lo 3 ~ ~ 2 0’,~- A.11. I 1 1 9 - HP ~ ~ IM I 15 L 1 1 8 = NIAt I C J1 5

  14. Imprints of superfluidity on magnetoelastic quasiperiodic oscillations of soft gamma-ray repeaters.

    PubMed

    Gabler, Michael; Cerdá-Durán, Pablo; Stergioulas, Nikolaos; Font, José A; Müller, Ewald

    2013-11-22

    Our numerical simulations show that axisymmetric, torsional, magnetoelastic oscillations of magnetars with a superfluid core can explain the whole range of observed quasiperiodic oscillations (QPOs) in the giant flares of soft gamma-ray repeaters. There exist constant phase QPOs at f is < or approximately equal to 150 Hz and resonantly excited high-frequency QPOs (f>500 Hz), in good agreement with observations. The range of magnetic field strengths required to match the observed QPO frequencies agrees with that from spin-down estimates. These results suggest that there is at least one superfluid species in magnetar cores.

  15. A Study on the Deriving Requirements of ARGO Operation System

    NASA Astrophysics Data System (ADS)

    Seo, Yoon-Kyung; Rew, Dong-Young; Lim, Hyung-Chul; Park, In-Kwan; Yim, Hong-Suh; Jo, Jung Hyun; Park, Jong-Uk

    2009-12-01

    Korea Astronomy and Space Science Institute (KASI) has been developing one mobile and one stationary SLR system since 2008 named as ARGO-M and ARGO-F, respectively. KASI finished the step of deriving the system requirements of ARGO. The requirements include definitions and scopes of various software and hardware components which are necessary for developing the ARGO-M operation system. And the requirements define function, performance, and interface requirements. The operation system consisting of ARGO-M site, ARGO-F site, and Remote Operation Center (ROC) inside KASI is designed for remote access and the automatic tracking and control system which are the main operation concept of ARGO system. To accomplish remote operation, we are considering remote access to ARGO-F and ARGO-M from ROC. The mobile-phone service allows us to access the ARGO-F remotely and to control the system in an emergency. To implement fully automatic tracking and control function in ARGO-F, we have investigated and described the requirements about the automatic aircraft detection system and the various meteorological sensors. This paper addresses the requirements of ARGO Operation System.

  16. 33 CFR 150.15 - What must the operations manual include?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... structure and systems. The operator must include schematics of all applicable systems. Schematics must show the location of valves, gauges, system working pressure, relief settings, monitoring systems, and other pertinent information. (d) Communications system. A description of a comprehensive communications...

  17. 33 CFR 150.15 - What must the operations manual include?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... structure and systems. The operator must include schematics of all applicable systems. Schematics must show the location of valves, gauges, system working pressure, relief settings, monitoring systems, and other pertinent information. (d) Communications system. A description of a comprehensive communications...

  18. 12 CFR 150.136 - To what extent do state laws apply to my fiduciary operations?

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... law; (4) Criminal law; (5) Probate law; and (6) Any other law that the OCC, upon review, finds: (i) Furthers a vital state interest; and (ii) Either has only an incidental effect on fiduciary operations or...

  19. 12 CFR 150.136 - To what extent do state laws apply to my fiduciary operations?

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... law; (4) Criminal law; (5) Probate law; and (6) Any other law that the OCC, upon review, finds: (i) Furthers a vital state interest; and (ii) Either has only an incidental effect on fiduciary operations or...

  20. 12 CFR 150.136 - To what extent do state laws apply to my fiduciary operations?

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... law; (4) Criminal law; (5) Probate law; and (6) Any other law that the OCC, upon review, finds: (i) Furthers a vital state interest; and (ii) Either has only an incidental effect on fiduciary operations or...

  1. 14 CFR Appendix F to Part 91 - Helicopter Flight Recorder Specifications

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 2 2012-01-01 2012-01-01 false Helicopter Flight Recorder Specifications F... (CONTINUED) AIR TRAFFIC AND GENERAL OPERATING RULES GENERAL OPERATING AND FLIGHT RULES Pt. 91, App. F Appendix F to Part 91—Helicopter Flight Recorder Specifications Parameters Range Installed system 1 minimum...

  2. On Volterra quadratic stochastic operators with continual state space

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ganikhodjaev, Nasir; Hamzah, Nur Zatul Akmar

    2015-05-15

    Let (X,F) be a measurable space, and S(X,F) be the set of all probability measures on (X,F) where X is a state space and F is σ - algebraon X. We consider a nonlinear transformation (quadratic stochastic operator) defined by (Vλ)(A) = ∫{sub X}∫{sub X}P(x,y,A)dλ(x)dλ(y), where P(x, y, A) is regarded as a function of two variables x and y with fixed A ∈ F . A quadratic stochastic operator V is called a regular, if for any initial measure the strong limit lim{sub n→∞} V{sup n }(λ) is exists. In this paper, we construct a family of quadratic stochastic operators defined on themore » segment X = [0,1] with Borel σ - algebra F on X , prove their regularity and show that the limit measure is a Dirac measure.« less

  3. Fission fragment yield distribution in the heavy-mass region from the 239Pu (nth,f ) reaction

    NASA Astrophysics Data System (ADS)

    Gupta, Y. K.; Biswas, D. C.; Serot, O.; Bernard, D.; Litaize, O.; Julien-Laferrière, S.; Chebboubi, A.; Kessedjian, G.; Sage, C.; Blanc, A.; Faust, H.; Köster, U.; Ebran, A.; Mathieu, L.; Letourneau, A.; Materna, T.; Panebianco, S.

    2017-07-01

    The fission fragment yield distribution has been measured in the 239Pu(nth,f ) reaction in the mass region of A =126 to 150 using the Lohengrin recoil-mass spectrometer. Three independent experimental campaigns were performed, allowing a significant reduction of the uncertainties compared to evaluated nuclear data libraries. The long-standing discrepancy of around 10% for the relative yield of A =134 reported in JEF-2.2 and JEFF-3.1.1 data libraries is finally solved. Moreover, the measured mass distribution in thermal neutron-induced fission does not show any significant dip around the shell closure (A =136 ) as seen in heavy-ion fission data of 208Pb(18O, f ) and 238U(18O, f ) reactions. Lastly, comparisons between our experimental data and the predictions from Monte Carlo codes (gef and fifrelin) are presented and discussed.

  4. Characterization of AlF3 thin films at 193 nm by thermal evaporation

    NASA Astrophysics Data System (ADS)

    Lee, Cheng-Chung; Liu, Ming-Chung; Kaneko, Masaaki; Nakahira, Kazuhide; Takano, Yuuichi

    2005-12-01

    Aluminum fluoride (AlF3) was deposited by a resistive heating boat. To obtain a low optical loss and high laser-induced damage threshold (LIDT) at 193 nm, the films were investigated under different substrate temperatures, deposition rates, and annealing after coating. The optical property (the transmittance, refractive index, extinction coefficient, and optical loss) at 193 nm, microstructure (the cross-sectional morphology, surface roughness, and crystalline structure), mechanical property (stress), and LIDT of AlF3 thin films have been studied. AlF3 thin films deposited at a high substrate temperature and low deposition rate showed a lower optical loss. The highest LIDT occurred at the substrate temperature of 150 °C. The LIDT of the films prepared at a deposition rate of 2 Å/s was higher than that at other deposition rates. The annealing process did not influence the optical properties too much, but it did increase the LIDT and stress.

  5. Characterization of AlF3 thin films at 193 nm by thermal evaporation.

    PubMed

    Lee, Cheng-Chung; Liu, Ming-Chung; Kaneko, Masaaki; Nakahira, Kazuhide; Takano, Yuuichi

    2005-12-01

    Aluminum fluoride (AlF3) was deposited by a resistive heating boat. To obtain a low optical loss and high laser-induced damage threshold (LIDT) at 193 nm, the films were investigated under different substrate temperatures, deposition rates, and annealing after coating. The optical property (the transmittance, refractive index, extinction coefficient, and optical loss) at 193 nm, microstructure (the cross-sectional morphology, surface roughness, and crystalline structure), mechanical property (stress), and LIDT of AlF3 thin films have been studied. AlF3 thin films deposited at a high substrate temperature and low deposition rate showed a lower optical loss. The highest LIDT occurred at the substrate temperature of 150 degrees C. The LIDT of the films prepared at a deposition rate of 2 A/s was higher than that at other deposition rates. The annealing process did not influence the optical properties too much, but it did increase the LIDT and stress.

  6. Classifying Saturn's F Ring Strands

    NASA Astrophysics Data System (ADS)

    Albers, Nicole; Sremcevic, M.; Esposito, L. W.; Colwell, J. E.

    2009-09-01

    The Cassini Ultraviolet Imaging Spectrograph (UVIS) High Speed Photometer (HSP) has recorded more than 113 stellar occultations by Saturn's F ring providing measurements with ring plane resolutions of a few dozen meters and better. Inner and outer F ring strands have been seen throughout the Cassini mission where they revealed themselves as non-continuous, azimuthally and temporally highly variable structures. In the light of a more accurate orbit description of the F ring core we find evidence for a ring that becomes dynamically more active as the system approaches anti-apse alignment with Prometheus. This is consistent with the observed increased strand activity. A recent strand that morphologically resembles the core is the strongest seen to date and points to the intricate relation between core and strands indicating the strands' violent creation. Using more than 150 identifications of various strands, we trace their kinematics and infer dynamical timescales and photometric properties. Implications for the dynamical evolution of the F ring will be discussed. This research was supported by the Cassini Project.

  7. Altered sperm chromatin structure in mice exposed to sodium fluoride through drinking water.

    PubMed

    Sun, Zilong; Niu, Ruiyan; Wang, Bin; Wang, Jundong

    2014-06-01

    This study investigated the effects of sodium fluoride (NaF) on sperm abnormality, sperm chromatin structure, protamine 1 and protamine 2 (P1 and P2) mRNA expression, and histones expression in sperm in male mice. NaF was orally administrated to male mice at 30, 70, and 150 mg/l for 49 days (more than one spermatogenic cycle). Sperm head and tail abnormalities were significantly enhanced at middle and high doses. Similarly, sperm chromatin structure was also adversely affected by NaF exposure, indicating DNA integrity damage. Furthermore, middle and high NaF significantly reduced the mRNA expressions of P1 and P2, and P1/P2 ratio, whereas the sperm histones level was increased, suggesting the abnormal histone-protamine replacement. Therefore, we concluded that the mechanism by which F induced mice sperm abnormality and DNA integrity damage may involved in the alterations in P1, P2, and histones expression in sperm of mice. Copyright © 2012 Wiley Periodicals, Inc.

  8. Improved hole-injection and power efficiency of organic light-emitting diodes using an ultrathin cerium fluoride buffer layer

    NASA Astrophysics Data System (ADS)

    Lu, Hsin-Wei; Kao, Po-Ching; Chu, Sheng-Yuan

    2016-09-01

    In this study, the efficiency of organic light-emitting diodes (OLEDs) was enhanced by depositing a CeF3 film as an ultra-thin buffer layer between the ITO and NPB hole transport layer, with the structure configuration ITO/CeF3 (1 nm)/NPB (40 nm)/Alq3 (60 nm)/LiF (1 nm)/Al (150 nm). The enhancement mechanism was systematically investigated via several approaches. The work function increased from 4.8 eV (standard ITO electrode) to 5.2 eV (1-nm-thick UV-ozone treated CeF3 film deposited on the ITO electrode). The turn-on voltage decreased from 4.2 V to 4.0 V at 1 mA/cm2, the luminance increased from 7588 cd/m2 to 10820 cd/m2, and the current efficiency increased from 3.2 cd/A to 3.5 cd/A when the 1-nm-thick UV-ozone treated CeF3 film was inserted into the OLEDs.

  9. Synthesis of carbon-coated Na2MnPO4F hollow spheres as a potential cathode material for Na-ion batteries

    NASA Astrophysics Data System (ADS)

    Wu, Ling; Hu, Yong; Zhang, Xiaoping; Liu, Jiequn; Zhu, Xing; Zhong, Shengkui

    2018-01-01

    Hollow sphere structure Na2MnPO4F/C composite is synthesized through spray drying, following in-situ pyrolytic carbon coating process. XRD results indicate that the well crystallized composite can be successfully synthesized, and no other impurity phases are detected. SEM and TEM results reveal that the Na2MnPO4F/C samples show intact hollow spherical architecture, and the hollow spherical shells with an average thickness of 150 nm-250 nm are composed of nanosized primary particles. Furthermore, the amorphous carbon layer is uniformly coated on the surface of the hollow sphere, and the nanosized Na2MnPO4F particles are well embedded in the carbon networks. Consequently, the hollow sphere structure Na2MnPO4F/C shows enhanced electrochemical performance. Especially, it is the first time that the obvious potential platforms (∼3.6 V) are observed during the charge and discharge process at room temperature.

  10. The effects of simulated space environmental parameters on six commercially available composite materials

    NASA Technical Reports Server (NTRS)

    Funk, Joan G.; Sykes, George F., Jr.

    1989-01-01

    The effects of simulated space environmental parameters on microdamage induced by the environment in a series of commercially available graphite-fiber-reinforced composite materials were determined. Composites with both thermoset and thermoplastic resin systems were studied. Low-Earth-Orbit (LEO) exposures were simulated by thermal cycling; geosynchronous-orbit (GEO) exposures were simulated by electron irradiation plus thermal cycling. The thermal cycling temperature range was -250 F to either 200 F or 150 F. The upper limits of the thermal cycles were different to ensure that an individual composite material was not cycled above its glass transition temperature. Material response was characterized through assessment of the induced microcracking and its influence on mechanical property changes at both room temperature and -250 F. Microdamage was induced in both thermoset and thermoplastic advanced composite materials exposed to the simulated LEO environment. However, a 350 F cure single-phase toughened epoxy composite was not damaged during exposure to the LEO environment. The simuated GEO environment produced microdamage in all materials tested.

  11. 76 FR 39645 - Exemptions for Advisers to Venture Capital Funds, Private Fund Advisers With Less Than $150...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-06

    ... FURTHER INFORMATION CONTACT: Brian McLaughlin Johnson, Tram N. Nguyen or David A. Vaughan, at (202) 551..., 100 F Street, NE., Washington, DC 20549-8549. SUPPLEMENTARY INFORMATION: The Commission is adopting... States 4. United States Person C. Foreign Private Advisers 1. Clients 2. Private Fund Investor 3. In the...

  12. 21 CFR 177.1970 - Vinyl chloride-lauryl vinyl ether copolymers.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... of the flask at 150 °F for 2 hours using a hot plate while also maintaining gentle mechanical agitation. Filter the contents of the flask rapidly through No. 42 Whatman filter paper with the aid of suction. Transfer the filtrate to flat glass dishes that are warmed on a hot plate and evaporate the...

  13. 78 FR 42153 - Decision That Certain Nonconforming Motor Vehicles Are Eligible for Importation

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-15

    ...- 2012-0162), the Ford Motor Company stated in pertinent part: Vehicles that are designed and... Market would have complied with FMVSS No. 208 at the time it was manufactured. The petitioner, Mesa Auto... Ford F-150 that was sold for the American market and the subject vehicle, in our research we discovered...

  14. 14 CFR 171.265 - Glide path performance requirements.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... depth of modulation of the radio frequency carrier due to each of the 90 Hz and 150 Hz tones must be 40... tone, which is the time average equivalent to amplitude modulation. The pattern must be arranged to... 5220 MHz to 5250 MHz. The frequency tolerance may not exceed ±0.0001 percent. (f) The emission from the...

  15. 26 CFR 5c.168(f)(8)-5 - Term of lease.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ..., or (2) 150 percent of the asset depreciation range (ADR) present class life (“midpoint”) of such... must at least equal the period prescribed under section 168(c)(2) for the recovery property class of... class, the lease agreement must have a minimum term of 5 years. In general, the determination of whether...

  16. Calculations of Shipboard Heat Exchangers,

    DTIC Science & Technology

    1980-04-18

    tubp plate with the Fercil cf szraight lines tutes (cn %’blepW68) d= I 1.&衊 == 0,563. Tha safety factcr c. panal is taken n=4. Allowable stress in...specific gravity/weight with 150C, kg/m 3 . ENDFOC[NOTE. (3). Petroleum residue F. (4). Cil. (5). turbine. (6). motor. (7). solar . t’ DOC 10

  17. 14 CFR Appendix F to Part 91 - Helicopter Flight Recorder Specifications

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ...-a) 1 25 to 150 ft. Magnetic Heading 360° ±5° 1 1° Vertical Acceleration −3g to +6g ±0.2g in addition to ±0.3g maximum datum 4 (or 1 per second where peaks, ref. to 1g are recorded) 0.05g. Longitudinal...

  18. SU-E-T-583: Operated Left Breast and Chest Wall Radiotherapy: A Dosimetric Comparison Between 3DCRT, IMRT and VMAT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sarkar, B; Roy, S; Munshi, A

    2015-06-15

    Purpose: To evaluate the comparative dosimetric efficacy between field and field 3DCRT(FnF), multiple field Intensity modulated radiotherapy (SnS IMRT) and, partial arc volumetric modulated arc therapy (VMAT) in case of post operative left side breast and chest wall irradiation. Methods: CT study set of fifteen post-operative left breast and chest wall patient was tested for a treatment plan of 50Gy in 25 fraction using partial arc VMAT, SnSIMRT and tangential beam 3DCRT . 3DCRT FnF gantry angle was ranging for left medial tangential 290±17{sup 0} and Lt lateral tangential l14°±12{sup 0}. For IMRT four fixed beam at gantry angle G130{supmore » 0} G110{sup 0} G300{sup 0} and G330{sup 0} was used, in case of insufficient dose another beam G150{sup 0} was added. In case of partial arc VMAT, lateral tangential arc G130{sup 0}-G100{sup 0} and medial tangential arc G280{sup 0}-G310{sup 0}. Inverse optimization was opted to cover at least 95%PTV by 95% prescription dose (RxD) and a strong weightage on reduction of heart and lung dose. PTV coverage was evaluated for it’s clinically acceptability depending on the tumor spatial location and its quadrant. Out of the three plans, any one was used for the actual patient treatment. Results: Dosimetric analysis done for breast PTV, left lung, heart and the opposite breast. PTV mean dose and maximum dose was 5129.8±214.8cGy, 4749.0±329.7cGy, 5024.6±73.4cGy and 5855.2±510.7cGy, 5340.7±146.1cGy, 5347.2±196.8cGy for FnF, VMAT and IMRT respectively. Ipsilateral lung volume receiving 20Gy and 5Gy was 23.6±9.5cGy and 32.7±10.3cGy for FnF, 18.6±8.7cGy and 38.8±15.2cGy for VMAT and 25.7±9.6cGy and 50.7±8.4cGy for IMRT respectively. Heart mean and 2cc dose was 867.9±456.7cGy and 5038.5±184.3cGy for FnF, 532.6±263cGy and 3632.1±990.6 for VMAT, 711±229.9cGy and 4421±463.7cGy for IMRT respectively. VMAT shows minimum contralateral breast dose 168±113.8cGy. Conclusion: VMAT shows a better tumor conformity, minimum heart, ipsilateral lung and opposite breast dose. Cardiac Toxicity and risk of contralateral breast cancer can be reduce using VMAT.« less

  19. Highly Uniform 150 mm Diameter Multichroic Polarimeter Array Deployed for CMB Detection

    NASA Technical Reports Server (NTRS)

    Ho, Shuay-Pwu Patty; Austermann, Jason; Beall, James A.; Choi, Steve K.; Cothard, Nicholas F.; Crowley, Kevin; Datta, Rahul; Devlin, Mark J.; Duff, Shannon M.; Wollack, Edward J.

    2016-01-01

    The Advanced Atacama Cosmology Telescope Polarimeter is an upgraded receiver for the Atacama Cosmology Telescope, which has begun making measurements of the small angular scale polarization anisotropies in the Cosmic Microwave Background using the first of four new multichroic superconducting detector arrays. Here, we review all details of the optimization and characterization of this first array, which features 2012 AlMn transition edge sensor bolometers operating at 150 and 230 GHz. We present critical temperatures, thermal conductivities,saturation powers, time constants, and sensitivities for the array. The results show high uniformity across the 150 mm wafer and good performance in the field.

  20. Plasma oscillation effects on nested Hall thruster operation and stability

    NASA Astrophysics Data System (ADS)

    McDonald, M. S.; Sekerak, M. J.; Gallimore, A. D.; Hofer, R. R.

    High-power Hall thrusters capable of throughput on the order of 100 kW are currently under development, driven by more demanding mission profiles and rapid growth in on-orbit solar power generation capability. At these power levels the nested Hall thruster (NHT), a new design that concentrically packs multiple thrusters into a single body with a shared magnetic circuit, offers performance and logistical advantages over conventional single-channel Hall thrusters. An important area for risk reduction in NHT development is quantifying inter-channel coupling between discharge channels. This work presents time- and frequency-domain discharge current and voltage measurements paired with high-speed video of the X2, a 10-kW class dual channel NHT. Two “ triads” of operating conditions at 150 V, 3.6 kW and 250 V, 8.6 kW were examined, including each channel in individual operation and both channels in joint operation. For both triads tested, dual-channel operation did not noticeably destabilize the discharge. Partial coupling of outer channel oscillations into the inner channel occurred at 150 V, though oscillation amplitudes did not change greatly. As a percentage of mean discharge current, RMS oscillations at 150 V increased from 8% to 13% on the inner channel and decreased from 10% to 8% on the outer channel from single- to dual-channel operation. At 250 V the RMS/mean level stayed steady at 13% on the inner channel and decreased from 7% to 6% on the outer channel. The only mean discharge parameter noticeably affected was the cathode floating potential, which decreased in magnitude below ground with increased absolute cathode flow rate in dual-channel mode. Rotating spokes were detected on high-speed video across all X2 operating cases with wavelength 12-18 cm, and spoke velocity generally increased from single- to dual-channel operation.

Top