Sample records for f-18 labeled glucopyranosyl

  1. Synthesis of [18F]-labelled Maltose Derivatives as PET Tracers for Imaging Bacterial Infection

    PubMed Central

    Namavari, Mohammad; Gowrishankar, Gayatri; Hoehne, Aileen; Jouannot, Erwan; Gambhir, Sanjiv S

    2015-01-01

    Purpose To develop novel positron emission tomography (PET) agents for visualization and therapy monitoring of bacterial infections. Procedures It is known that maltose and maltodextrins are energy sources for bacteria. Hence, 18F-labelled maltose derivatives could be a valuable tool for imaging bacterial infections. We have developed methods to synthesize 4-O-(α-D-glucopyranosyl)-6-deoxy-6-[18F]fluoro-D-glucopyranoside (6-[18F]fluoromaltose) and 4-O-(α-D-glucopyranosyl)-1-deoxy-1-[18F]fluoro-D-glucopyranoside (1-[18F]fluoromaltose) as bacterial infection PET imaging agents. 6-[18F]fluoromaltose was prepared from precursor 1,2,3-tri-O-acetyl-4-O-(2′,3′,-di-O-acetyl-4′,6′-benzylidene-α-D-glucopyranosyl)-6-deoxy-6-nosyl-D-glucopranoside (5). The synthesis involved the radio-fluorination of 5 followed by acidic and basic hydrolysis to give 6-[18F]fluoromaltose. In an analogous procedure, 1-[18F]fluoromaltose was synthesized from 2,3, 6-tri-O-acetyl-4-O-(2′,3′,4′,6-tetra-O-acetyl-α-D-glucopyranosyl)-1-deoxy-1-O-triflyl-D-glucopranoside (9). Stability of 6-[18F]fluoromaltose in phosphate-buffered saline (PBS) and human and mouse serum at 37 °C was determined. Escherichia coli uptake of 6-[18F]fluoromaltose was examined. Results A reliable synthesis of 1- and 6-[18F]fluoromaltose has been accomplished with 4–6 and 5–8 % radiochemical yields, respectively (decay-corrected with 95 % radiochemical purity). 6-[18F]fluoromaltose was sufficiently stable over the time span needed for PET studies (~96 % intact compound after 1-h and ~65 % after 2-h incubation in serum). Bacterial uptake experiments indicated that E. coli transports 6-[18F]fluoromaltose. Competition assays showed that the uptake of 6-[18F]fluoromaltose was completely blocked by co-incubation with 1 mM of the natural substrate maltose. Conclusion We have successfully synthesized 1- and 6-[18F]fluoromaltose via direct fluorination of appropriate protected maltose precursors. Bacterial uptake

  2. 18F-labeled norepinephrine transporter tracer [18F]NS12137: radiosynthesis and preclinical evaluation.

    PubMed

    Kirjavainen, Anna K; Forsback, Sarita; López-Picón, Francisco R; Marjamäki, Päivi; Takkinen, Jatta; Haaparanta-Solin, Merja; Peters, Dan; Solin, Olof

    2018-01-01

    Several psychiatric and neurodegenerative diseases are associated with malfunction of brain norepinephrine transporter (NET). However, current clinical evaluations of NET function are limited by the lack of sufficiently sensitive methods of detection. To this end, we have synthesized exo-3-[(6-[ 18 F]fluoro-2-pyridyl)oxy]-8-azabicyclo[3.2.1]-octane ([ 18 F]NS12137) as a radiotracer for positron emission tomography (PET) and have demonstrated that it is highly specific for in vivo detection of NET-rich regions of rat brain tissue. We applied two methods of electrophilic, aromatic radiofluorination of the precursor molecule, exo-3-[(6-trimethylstannyl-2-pyridyl)oxy]-8-azabicyclo-[3.2.1]octane-8-carboxylate: (1) direct labeling with [ 18 F]F 2 , and (2) labeling with [ 18 F]Selectfluor, a derivative of [ 18 F]F 2 , using post-target produced [ 18 F]F 2 . The time-dependent distribution of [ 18 F]NS12137 in brain tissue of healthy, adult Sprague-Dawley rats was determined by ex vivo autoradiography. The specificity of [ 18 F]NS12137 binding was demonstrated on the basis of competitive binding by nisoxetine, a known NET antagonist of high specificity. [ 18 F]NS12137 was successfully synthesized with radiochemical yields of 3.9% ± 0.3% when labeled with [ 18 F]F 2 and 10.2% ± 2.7% when labeled with [ 18 F]Selectfluor. The molar activity of radiotracer was 8.8 ± 0.7 GBq/μmol with [ 18 F]F 2 labeling and 6.9 ± 0.4 GBq/μmol with [ 18 F]Selectfluor labeling at the end of synthesis of [ 18 F]NS12137. Uptake of [ 18 F]NS12137 in NET-rich areas in rat brain was demonstrated with the locus coeruleus (LCoe) having the highest regional uptake. Prior treatment of rats with nisoxetine showed no detectable [ 18 F]NS12137 in the LCoe. Analyses of whole brain samples for radiometabolites showed only the parent compound [ 18 F]NS12137. Uptake of 18 F-radioactivity in bone increased with time. The two electrophilic 18 F-labeling methods proved to be suitable for synthesis of [ 18 F

  3. A novel facile method of labeling octreotide with (18)F-fluorine.

    PubMed

    Laverman, Peter; McBride, William J; Sharkey, Robert M; Eek, Annemarie; Joosten, Lieke; Oyen, Wim J G; Goldenberg, David M; Boerman, Otto C

    2010-03-01

    Several methods have been developed to label peptides with (18)F. However, in general these are laborious and require a multistep synthesis. We present a facile method based on the chelation of (18)F-aluminum fluoride (Al(18)F) by 1,4,7-triazacyclononane-1,4,7-triacetic acid (NOTA). The method is characterized by the labeling of NOTA-octreotide (NOTA-d-Phe-cyclo[Cys-Phe-d-Trp-Lys-Thr-Cys]-Throl (MH(+) 1305) [IMP466]) with (18)F. Octreotide was conjugated with the NOTA chelate and labeled with (18)F in a 2-step, 1-pot method. The labeling procedure was optimized with regard to the labeling buffer, peptide, and aluminum concentration. Radiochemical yield, specific activity, in vitro stability, and receptor affinity were determined. Biodistribution of (18)F-IMP466 was studied in AR42J tumor-bearing mice and compared with that of (68)Ga-labeled IMP466. In addition, small-animal PET/CT images were acquired. IMP466 was labeled with Al(18)F in a single step with 50% yield. The labeled product was purified by high-performance liquid chromatography to remove unbound Al(18)F and unlabeled peptide. The radiolabeling, including purification, was performed in 45 min. The specific activity was 45,000 GBq/mmol, and the peptide was stable in serum for 4 h at 37 degrees C. Labeling was performed at pH 4.1 in sodium citrate, sodium acetate, 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid, and 2-(N-morpholino)ethanesulfonic acid buffer and was optimal in sodium acetate buffer. The apparent 50% inhibitory concentration of the (19)F-labeled IMP466 determined on AR42J cells was 3.6 nM. Biodistribution studies at 2 h after injection showed a high tumor uptake of (18)F-IMP466 (28.3 +/- 5.2 percentage injected dose per gram [%ID/g]; tumor-to-blood ratio, 300 +/- 90), which could be blocked by an excess of unlabeled peptide (8.6 +/- 0.7 %ID/g), indicating that the accumulation in the tumor was receptor-mediated. Biodistribution of (68)Ga-IMP466 was similar to that of (18)F-IMP466. (18)F

  4. Al18F-Labeling Of Heat-Sensitive Biomolecules for Positron Emission Tomography Imaging.

    PubMed

    Cleeren, Frederik; Lecina, Joan; Ahamed, Muneer; Raes, Geert; Devoogdt, Nick; Caveliers, Vicky; McQuade, Paul; Rubins, Daniel J; Li, Wenping; Verbruggen, Alfons; Xavier, Catarina; Bormans, Guy

    2017-01-01

    Positron emission tomography (PET) using radiolabeled biomolecules is a translational molecular imaging technology that is increasingly used in support of drug development. Current methods for radiolabeling biomolecules with fluorine-18 are laborious and require multistep procedures with moderate labeling yields. The Al 18 F-labeling strategy involves chelation in aqueous medium of aluminum mono[ 18 F]fluoride ({Al 18 F} 2+ ) by a suitable chelator conjugated to a biomolecule. However, the need for elevated temperatures (100-120 °C) required for the chelation reaction limits its widespread use. Therefore, we designed a new restrained complexing agent (RESCA) for application of the AlF strategy at room temperature. Methods. The new chelator RESCA was conjugated to three relevant biologicals and the constructs were labeled with {Al 18 F} 2+ to evaluate the generic applicability of the one-step Al 18 F-RESCA-method. Results. We successfully labeled human serum albumin with excellent radiochemical yields in less than 30 minutes and confirmed in vivo stability of the Al 18 F-labeled protein in rats. In addition, we efficiently labeled nanobodies targeting the Kupffer cell marker CRIg, and performed µPET studies in healthy and CRIg deficient mice to demonstrate that the proposed radiolabeling method does not affect the functional integrity of the protein. Finally, an affibody targeting HER2 (PEP04314) was labeled site-specifically, and the distribution profile of (±)-[ 18 F]AlF(RESCA)-PEP04314 in a rhesus monkey was compared with that of [ 18 F]AlF(NOTA)-PEP04314 using whole-body PET/CT. Conclusion. This generic radiolabeling method has the potential to be a kit-based fluorine-18 labeling strategy, and could have a large impact on PET radiochemical space, potentially enabling the development of many new fluorine-18 labeled protein-based radiotracers.

  5. Al18F-Labeling Of Heat-Sensitive Biomolecules for Positron Emission Tomography Imaging

    PubMed Central

    Cleeren, Frederik; Lecina, Joan; Ahamed, Muneer; Raes, Geert; Devoogdt, Nick; Caveliers, Vicky; McQuade, Paul; Rubins, Daniel J; Li, Wenping; Verbruggen, Alfons; Xavier, Catarina; Bormans, Guy

    2017-01-01

    Positron emission tomography (PET) using radiolabeled biomolecules is a translational molecular imaging technology that is increasingly used in support of drug development. Current methods for radiolabeling biomolecules with fluorine-18 are laborious and require multistep procedures with moderate labeling yields. The Al18F-labeling strategy involves chelation in aqueous medium of aluminum mono[18F]fluoride ({Al18F}2+) by a suitable chelator conjugated to a biomolecule. However, the need for elevated temperatures (100-120 °C) required for the chelation reaction limits its widespread use. Therefore, we designed a new restrained complexing agent (RESCA) for application of the AlF strategy at room temperature. Methods. The new chelator RESCA was conjugated to three relevant biologicals and the constructs were labeled with {Al18F}2+ to evaluate the generic applicability of the one-step Al18F-RESCA-method. Results. We successfully labeled human serum albumin with excellent radiochemical yields in less than 30 minutes and confirmed in vivo stability of the Al18F-labeled protein in rats. In addition, we efficiently labeled nanobodies targeting the Kupffer cell marker CRIg, and performed µPET studies in healthy and CRIg deficient mice to demonstrate that the proposed radiolabeling method does not affect the functional integrity of the protein. Finally, an affibody targeting HER2 (PEP04314) was labeled site-specifically, and the distribution profile of (±)-[18F]AlF(RESCA)-PEP04314 in a rhesus monkey was compared with that of [18F]AlF(NOTA)-PEP04314 using whole-body PET/CT. Conclusion. This generic radiolabeling method has the potential to be a kit-based fluorine-18 labeling strategy, and could have a large impact on PET radiochemical space, potentially enabling the development of many new fluorine-18 labeled protein-based radiotracers. PMID:28824726

  6. New Chelators for Low Temperature Al(18)F-Labeling of Biomolecules.

    PubMed

    Cleeren, Frederik; Lecina, Joan; Billaud, Emilie M F; Ahamed, Muneer; Verbruggen, Alfons; Bormans, Guy M

    2016-03-16

    The Al(18)F labeling method is a relatively new approach that allows radiofluorination of biomolecules such as peptides and proteins in a one-step procedure and in aqueous solution. However, the chelation of the {Al(18)F}(2+) core with the macrocyclic chelators NOTA or NODA requires heating to 100-120 °C. Therefore, we have developed new polydentate ligands for the complexation of {Al(18)F}(2+) with good radiochemical yields at a temperature of 40 °C. The stability of the new Al(18)F-complexes was tested in phosphate buffered saline (PBS) at pH 7.4 and in rat serum. The stability of the Al(18)F-L3 complex was found to be comparable to that of the previously reported Al(18)F-NODA complex up to 60 min in rat serum. Moreover, the biodistribution of Al(18)F-L3 in healthy mice showed the absence of in vivo defluorination since no significant bone uptake was observed, whereas the major fraction of activity at 60 min p.i. was observed in liver and intestines, indicating hepatobiliary clearance of the radiolabeled ligand. The acyclic chelator H3L3 proved to be a good lead candidate for labeling of heat-sensitive biomolecules with fluorine-18. In order to obtain a better understanding of the different factors influencing the formation and stability of the complex, we carried out more in-depth experiments with ligand H3L3. As a proof of concept, we successfully conjugated the new AlF-chelator with the urea-based PSMA inhibitor Glu-NH-CO-NH-Lys to form Glu-NH-CO-NH-Lys(Ahx)L3, and a biodistribution study in healthy mice was performed with the Al(18)F-labeled construct. This new class of AlF-chelators may have a great impact on PET radiochemical space as it will stimulate the rapid development of new fluorine-18 labeled peptides and other heat-sensitive biomolecules.

  7. Sulfonyl fluoride-based prosthetic compounds as potential 18F labelling agents.

    PubMed

    Inkster, James A H; Liu, Kate; Ait-Mohand, Samia; Schaffer, Paul; Guérin, Brigitte; Ruth, Thomas J; Storr, Tim

    2012-08-27

    Nucleophilic incorporation of [(18)F]F(-) under aqueous conditions holds several advantages in radiopharmaceutical development, especially with the advent of complex biological pharmacophores. Sulfonyl fluorides can be prepared in water at room temperature, yet they have not been assayed as a potential means to (18)F-labelled biomarkers for PET chemistry. We developed a general route to prepare bifunctional 4-formyl-, 3-formyl-, 4-maleimido- and 4-oxylalkynl-arylsulfonyl [(18)F]fluorides from their sulfonyl chloride analogues in 1:1 mixtures of acetonitrile, THF, or tBuOH and Cs[(18)F]F/Cs(2)CO(3(aq.)) in a reaction time of 15 min at room temperature. With the exception of 4-N-maleimide-benzenesulfonyl fluoride (3), pyridine could be used to simplify radiotracer purification by selectively degrading the precursor without significantly affecting observed yields. The addition of pyridine at the start of [(18)F]fluorination (1:1:0.8 tBuOH/Cs(2)CO(3(aq.))/pyridine) did not negatively affect yields of 3-formyl-2,4,6-trimethylbenzenesulfonyl [(18)F]fluoride (2) and dramatically improved the yields of 4-(prop-2-ynyloxy)benzenesulfonyl [(18)F]fluoride (4). The N-arylsulfonyl-4-dimethylaminopyridinium derivative of 4 (14) can be prepared and incorporates (18)F efficiently in solutions of 100 % aqueous Cs(2)CO(3) (10 mg mL(-1)). As proof-of-principle, [(18)F]2 was synthesised in a preparative fashion [88(±8) % decay corrected (n=6) from start-of-synthesis] and used to radioactively label an oxyamino-modified bombesin(6-14) analogue [35(±6) % decay corrected (n=4) from start-of-synthesis]. Total preparation time was 105-109 min from start-of-synthesis. Although the (18)F-peptide exhibited evidence of proteolytic defluorination and modification, our study is the first step in developing an aqueous, room temperature (18)F labelling strategy. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. 18F-Labeling of Sensitive Biomolecules for Positron Emission Tomography

    PubMed Central

    Krishnan, Hema S.; Ma, Longle; Vasdev, Neil; Liang, Steven H.

    2017-01-01

    Positron emission tomography (PET) imaging study of fluorine-18 labeled biomolecules is an emerging and rapidly growing area for preclinical and clinical research. The present review focuses on recent advances in radiochemical methods for incorporating fluorine-18 into biomolecules via ‘direct’ or ‘indirect’ bioconjugation. Recently developed prosthetic groups and pre-targeting strategies, as well as representative examples in 18F-labeling of biomolecules in PET imaging research studies are highlighted. PMID:28704575

  9. 18 F-Labeling of Sensitive Biomolecules for Positron Emission Tomography.

    PubMed

    Krishnan, Hema S; Ma, Longle; Vasdev, Neil; Liang, Steven H

    2017-11-07

    Positron emission tomography (PET) imaging study of fluorine-18 labeled biomolecules is an emerging and rapidly growing area for preclinical and clinical research. The present review focuses on recent advances in radiochemical methods for incorporating fluorine-18 into biomolecules via "direct" or "indirect" bioconjugation. Recently developed prosthetic groups and pre-targeting strategies, as well as representative examples in 18 F-labeling of biomolecules in PET imaging research studies are highlighted. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Facile purification and click labeling with 2-[ 18F]fluoroethyl azide using solid phase extraction cartridges

    DOE PAGES

    Zhou, Dong; Chu, Wenhua; Peng, Xin; ...

    2014-11-04

    In this paper, a facile method was developed to purify 2-[ 18F]fluoroethyl azide ([ 18F]FEA) using a C18 cartridge and an Oasis® HLB cartridge in series, in which [18F]FEA was exclusively trapped on the HLB cartridge. [ 18F]FEA can be eluted for reactions in solution; alternatively click labeling can be carried out on the HLB cartridge itself by loading an alkyne substrate and copper (I) catalyst dissolved in DMF onto the cartridge. Finally, this solid phase extraction methodology for purification and click labeling with [ 18F]FEA, either in solution or on the cartridge, is safe, simple, reproducible in high yield,more » and compatible with automated synthesis of 18F-labeled PET tracers.« less

  11. Advances in PET myocardial perfusion imaging: F-18 labeled tracers.

    PubMed

    Rischpler, Christoph; Park, Min-Jae; Fung, George S K; Javadi, Mehrbod; Tsui, Benjamin M W; Higuchi, Takahiro

    2012-01-01

    Coronary artery disease and its related cardiac disorders represent the most common cause of death in the USA and Western world. Despite advancements in treatment and accompanying improvements in outcome with current diagnostic and therapeutic modalities, it is the correct assignment of these diagnostic techniques and treatment options which are crucial. From a diagnostic standpoint, SPECT myocardial perfusion imaging (MPI) using traditional radiotracers like thallium-201 chloride, Tc-99m sestamibi or Tc-99m tetrofosmin is the most utilized imaging technique. However, PET MPI using N-13 ammonia, rubidium-82 chloride or O-15 water is increasing in availability and usage as a result of the growing number of medical centers with new-generation PET/CT systems taking advantage of the superior imaging properties of PET over SPECT. The routine clinical use of PET MPI is still limited, in part because of the short half-life of conventional PET MPI tracers. The disadvantages of these conventional PET tracers include expensive onsite production and inconvenient on-scanner tracer administration making them unsuitable for physical exercise stress imaging. Recently, two F-18 labeled radiotracers with longer radioactive half-lives than conventional PET imaging agents have been introduced. These are flurpiridaz F 18 (formerly known as F-18 BMS747158-02) and F-18 fluorobenzyltriphenylphosphonium. These longer half-life F-18 labeled perfusion tracers can overcome the production and protocol limitations of currently used radiotracers for PET MPI.

  12. Biological characterization of F-18-labeled rhodamine B, a potential positron emission tomography perfusion tracer.

    PubMed

    Bartholomä, Mark D; He, Huamei; Pacak, Christina A; Dunning, Patricia; Fahey, Frederic H; McGowan, Francis X; Cowan, Douglas B; Treves, S Ted; Packard, Alan B

    2013-11-01

    Myocardial infarction is the leading cause of death in western countries, and positron emission tomography (PET) plays an increasing role in the diagnosis and treatment planning for this disease. However, the absence of an (18)F-labeled PET myocardial perfusion tracer hampers the widespread use of PET in myocardial perfusion imaging (MPI). We recently reported a potential MPI agent based on (18)F-labeled rhodamine B. The goal of this study was to more completely define the biological properties of (18)F-labeled rhodamine B with respect to uptake and localization in an animal model of myocardial infarction and to evaluate the uptake (18)F-labeled rhodamine B by cardiomyocytes. A total of 12 female Sprague Dawley rats with a permanent ligation of the left anterior descending artery (LAD) were studied with small-animal PET. The animals were injected with 100-150 μCi of (18)F-labeled rhodamine B diethylene glycol ester ([(18)F]RhoBDEGF) and imaged two days before ligation. The animals were imaged again two to ten days post-ligation. After the post-surgery scans, the animals were euthanized and the hearts were sectioned into 1mm slices and myocardial infarct size was determined by phosphorimaging and 2,3,5-triphenyltetrazolium chloride staining (TTC). In addition, the uptake of [(18)F]RhoBDEGF in isolated rat neonatal cardiomyocytes was determined by fluorescence microscopy. Small-animal PET showed intense and uniform uptake of [(18)F]RhoBDEGF throughout the myocardium in healthy rats. After LAD ligation, well defined perfusion defects were observed in the PET images. The defect size was highly correlated with the infarct size as determined ex vivo by phosphorimaging and TTC staining. In vitro, [(18)F]RhoBDEGF was rapidly internalized into rat cardiomyocytes with ~40 % of the initial activity internalized within the 60 min incubation time. Fluorescence microscopy clearly demonstrated localization of [(18)F]RhoBDEGF in the mitochondria of rat cardiomyocytes. Fluorine-18

  13. Biological Characterization of F-18-Labeled Rhodamine B, a Potential Positron Emission Tomography Perfusion Tracer

    PubMed Central

    Bartholomä, Mark D.; He, Huamei; Pacak, Christina; Dunning, Patricia; Fahey, Frederic H.; McGowan, Francis; Cowan, Douglas; Treves, S. Ted; Packard, Alan B.

    2013-01-01

    Introduction Myocardial infarction is the leading cause of death in western countries, and positron emission tomography (PET) plays an increasing role in the diagnosis and treatment planning for this disease. However, the absence of an F-18-labeled PET myocardial perfusion tracer hampers the widespread use of PET in myocardial perfusion imaging (MPI). We recently reported a potential MPI agent based on F-18-labeled rhodamine B. The goal of this study was to more completely define the biological properties of F-18-labeled rhodamine B with respect to uptake and localization in an animal model of myocardial infarction and to evaluate the uptake F-18-labeled rhodamine B by cardiomyocytes. Methods A total of 12 female Sprague Dawley rats with a permanent ligation of the left anterior descending artery (LAD) were studied with small-animal PET. The animals were injected with 100–150 µCi of F-18-labeled rhodamine B diethylene glycol ester ([18F]RhoBDEGF) and imaged two days before ligation. The animals were imaged again two to ten days post-ligation. After the post-surgery scans, the animals were euthanized and the hearts were sectioned into 1 mm slices and myocardial infarct size was determined by phosphorimaging and 2,3,5-triphenyltetrazolium chloride staining (TTC). In addition, the uptake of [18F]RhoBDEGF in isolated rat neonatal cardiomyocytes was determined by fluorescence microscopy. Results Small-animal PET showed intense and uniform uptake of [18F]RhoBDEGF throughout the myocardium in healthy rats. After LAD ligation, well defined perfusion defects were observed in the PET images. The defect size was highly correlated with the infarct size as determined ex vivo by phosphorimaging and TTC staining. In vitro, [18F]RhoBDEGF was rapidly internalized into rat cardiomyocytes with ~40 % of the initial activity internalized within the 60 min incubation time. Fluorescence microscopy clearly demonstrated localization of [18F]RhoBDEGF in the mitochondria of rat

  14. Multimodality Molecular Imaging of [18F]-Fluorinated Carboplatin Derivative Encapsulated in [111In]-Labeled Liposomes

    NASA Astrophysics Data System (ADS)

    Lamichhane, Narottam

    -(5-fluoro-pentyl)-2-methyl malonic acid as the labeling agent to coordinate with the cisplatin aqua complex. It was then used to treat various cell lines and compared with cisplatin and carboplatin at different concentrations ranging from 0.001 microM to 100 microM for 72 hrs and 96 hrs. IC50 values calculated from cell viability indicated that 19F-FCP is a more potent drug than Carboplatin. Manual radiosynthesis and characterization of [18F]-FCP was performed using [18F]-2-(5-fluoro-pentyl)-2-methyl malonic acid with coordination with cisplatin aqua complex. Automated radiosynthesis of [18F]-FCP was optimized using the manual synthetic procedures and using them as macros for the radiosynthesizer. [18F]-FCP was evaluated in vivo with detailed biodistribution studies and PET imaging in normal and KB 3-1 and KB 8-5 tumor xenograft bearing nude mice. The biodistribution studies and PET imaging of [18F]-FCP showed major uptake in kidneys which attributes to the renal clearance of radiotracer. In vivo plasma and urine stability demonstrated intact [18F]-FCP. [ 111In]-Labeled Liposomes was synthesized and physiochemical properties were assessed with DLS. [111In]-Labeled Liposome was evaluated in vivo with detailed pharmacokinetic studies and SPECT imaging. The biodistribution and ROI analysis from SPECT imaging showed the spleen and liver uptake of [111In]-Labeled Liposome and subsequent clearance of activity with time. [18F]-FCP encapsulated [111In]-Labeled Liposome was developed and physiochemical properties were characterized with DLS. [18F]-FCP encapsulated [111In]-Labeled Liposome was used for in vivo dual tracer PET and SPECT imaging from the same nanoconstruct in KB 3-1 (sensitive) and COLO 205 (resistant) tumor xenograft bearing nude mice. PET imaging of [18F]-FCP in KB 3-1 (sensitive) and COLO 205 (resistant) tumor xenograft bearing nude mice was performed. Naked [18F]-FCP and [18F]-FCP encapsulated [ 111In]-Labeled Liposome showed different pharmacokinetic profiles. PET

  15. Improved 18F Labeling of Peptides with a Fluoride-Aluminum-Chelate Complex

    PubMed Central

    McBride, William J.; D’Souza, Christopher A.; Sharkey, Robert M.; Karacay, Habibe; Rossi, Edmund A.; Chang, Chien-Hsing; Goldenberg, David M.

    2010-01-01

    We reported previously the feasibility to radiolabel peptides with fluorine-18 (18F) using a rapid, one-pot, method that first mixes 18F− with Al3+, and then binds the (Al18F)2+ complex to a NOTA ligand on the peptide. In this report, we examined several new NOTA ligands and determined how temperature, reaction time, and reagent concentration affected the radiolabeling yield. Four structural variations of the NOTA ligand had isolated radiolabeling yields ranging from 5.8% to 87% under similar reaction conditions. All of the Al18F NOTA complexes were stable in vitro in human serum and those that were tested in vivo also were stable. The radiolabeling reactions were performed at 100°C and the peptides could be labeled in as little as five minutes. The IMP467 peptide could be labeled up to 115 GBq/μmol (3100 Ci/mmol), with a total reaction and purification time of 30 min without chromatographic purification. PMID:20540570

  16. Synthesis and characterization of (18)F-labeled active site inhibited factor VII (ASIS).

    PubMed

    Erlandsson, Maria; Nielsen, Carsten H; Jeppesen, Troels E; Kristensen, Jesper B; Petersen, Lars C; Madsen, Jacob; Kjaer, Andreas

    2015-05-15

    Activated factor VII blocked in the active site with Phe-Phe-Arg-chloromethyl ketone (active site inhibited factor VII (ASIS)) is a 50-kDa protein that binds with high affinity to its receptor, tissue factor (TF). TF is a transmembrane glycoprotein that plays an important role in, for example, thrombosis, metastasis, tumor growth, and tumor angiogenesis. The aim of this study was to develop an (18)F-labeled ASIS derivative to assess TF expression in tumors. Active site inhibited factor VII was labeled using N-succinimidyl-4-[(18)F]fluorobenzoate, and the [(18)F]ASIS was purified on a PD-10 desalting column. The radiochemical yield was 25 ± 6%, the radiochemical purity was >97%, and the pseudospecific radioactivity was 35 ± 9 GBq/µmol. The binding efficacy was evaluated in pull-down experiments, which monitored the binding of unlabeled ASIS and [(18)F]ASIS to TF and to a specific anti-factor VII antibody (F1A2-mAb). No significant difference in binding efficacy between [(18)F]ASIS and ASIS could be detected. Furthermore, [(18)F]ASIS was relatively stable in vitro and in vivo in mice. In conclusion, [(18)F]ASIS has for the first time been successfully synthesized as a possible positron emission tomography tracer to image TF expression levels. In vivo positron emission tomography studies to evaluate the full potential of [(18)F]ASIS are in progress. Copyright © 2015 John Wiley & Sons, Ltd.

  17. One-pot production of 18F-biotin by conjugation with 18F-FDG for pre-targeted imaging: synthesis and radio-labelling of a PEGylated precursor.

    PubMed

    Simpson, Michael; Trembleau, Laurent; Cheyne, Richard W; Smith, Tim A D

    2011-02-01

    The biotin-avidin affinity system is exploited in pre-targeted imaging using avidin-conjugated antibodies. (18)F-FDG is available at all PET centres. (18)F-FDG forms oximes by reaction with oxyamine. Herein we describe the synthesis of oxyamine-funtionalised biotin, its (18)F-labelling by conjugation with (18)F-FDG and confirm its ability to interact with avidin. Copyright © 2010 Elsevier Ltd. All rights reserved.

  18. 18F-labeled Rhodamines as Potential Myocardial Perfusion Agents: Comparison of Pharmacokinetic Properties of Several Rhodamines

    PubMed Central

    Bartholoma, Mark D.; Zhang, Shaohui; Akurathi, Vamsidhar; Pacak, Christina A.; Dunning, Patricia; Fahey, Frederic H.; Cowan, Douglas B.; Treves, S. Ted; Packard, Alan B.

    2015-01-01

    Introduction We recently reported the development of the [18F]fluorodiethylene glycol ester of rhodamine B as a potential positron emission tomography (PET) tracer for myocardial perfusion imaging (MPI). This compound was developed by optimizing the ester moiety on the rhodamine B core, and its pharmacokinetic properties were found to be superior to those of the prototype ethyl ester. The goal of the present study was to optimize the rhodamine core while retaining the fluorodiethyleneglycol ester prosthetic group. Methods A series of different rhodamine cores (rhodamine 6G, rhodamine 101, and tetramethylrhodamine) were labeled with 18F using the corresponding rhodamine lactones as the precursors and [18F]fluorodiethylene glycol ester as the prosthetic group. The compounds were purified by semipreparative HPLC, and their biodistribution was measured in rats. Additionally, the uptake of the compounds was evaluated in isolated rat cardiomyocytes. Results As was the case with the different prosthetic groups, we found that the rhodamine core has a significant effect on the in vitro and in vivo properties of this series of compounds. Of the rhodamines evaluated to date, the pharmacologic properties of the 18F-labeled diethylene glycol ester of rhodamine 6G are superior to those of the 18F-labeled diethylene glycol esters of rhodamine B, rhodamine 101, and tetramethylrhodamine. As with 18F-labeled rhodamine B, [18F]rhodamine 6G was observed to localize in the mitochondria of isolated rat cardiomyocytes. Conclusions Based on these results, the 18F-labeled diethylene glycol ester of rhodamine 6G is the most promising potential PET MPI radiopharmaceutical of those that have been evaluated to date, and we are now preparing to carry out first-in-human clinical studies with this compound. PMID:26205075

  19. (18)F-labeled rhodamines as potential myocardial perfusion agents: comparison of pharmacokinetic properties of several rhodamines.

    PubMed

    Bartholomä, Mark D; Zhang, Shaohui; Akurathi, Vamsidhar; Pacak, Christina A; Dunning, Patricia; Fahey, Frederic H; Cowan, Douglas B; Treves, S Ted; Packard, Alan B

    2015-10-01

    We recently reported the development of the [(18)F]fluorodiethylene glycol ester of rhodamine B as a potential positron emission tomography (PET) tracer for myocardial perfusion imaging (MPI). This compound was developed by optimizing the ester moiety on the rhodamine B core, and its pharmacokinetic properties were found to be superior to those of the prototype ethyl ester. The goal of the present study was to optimize the rhodamine core while retaining the fluorodiethyleneglycol ester prosthetic group. A series of different rhodamine cores (rhodamine 6G, rhodamine 101, and tetramethylrhodamine) were labeled with (18)F using the corresponding rhodamine lactones as the precursors and [(18)F]fluorodiethylene glycol ester as the prosthetic group. The compounds were purified by semipreparative HPLC, and their biodistribution was measured in rats. Additionally, the uptake of the compounds was evaluated in isolated rat cardiomyocytes. As was the case with the different prosthetic groups, we found that the rhodamine core has a significant effect on the in vitro and in vivo properties of this series of compounds. Of the rhodamines evaluated to date, the pharmacologic properties of the (18)F-labeled diethylene glycol ester of rhodamine 6G are superior to those of the (18)F-labeled diethylene glycol esters of rhodamine B, rhodamine 101, and tetramethylrhodamine. As with (18)F-labeled rhodamine B, [(18)F]rhodamine 6G was observed to localize in the mitochondria of isolated rat cardiomyocytes. Based on these results, the (18)F-labeled diethylene glycol ester of rhodamine 6G is the most promising potential PET MPI radiopharmaceutical of those that have evaluated to date, and we are now preparing to carry out first-in-human clinical studies with this compound. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. PET/CT with 18F-FDG- and 18F-FBEM-labeled leukocytes for metabolic activity and leukocyte recruitment monitoring in a mouse model of pulmonary fibrosis.

    PubMed

    Bondue, Benjamin; Sherer, Félicie; Van Simaeys, Gaetan; Doumont, Gilles; Egrise, Dominique; Yakoub, Yousof; Huaux, François; Parmentier, Marc; Rorive, Sandrine; Sauvage, Sébastien; Lacroix, Simon; Vosters, Olivier; De Vuyst, Paul; Goldman, Serge

    2015-01-01

    Idiopathic pulmonary fibrosis is characterized by a progressive and irreversible respiratory failure. Validated noninvasive methods able to assess disease activity are essential for prognostic purposes as well as for the evaluation of emerging antifibrotic treatments. C57BL/6 mice were used in a murine model of pulmonary fibrosis induced by an intratracheal instillation of bleomycin (control mice were instilled with a saline solution). At different times after instillation, PET/CT with (18)F-FDG- or (18)F-4-fluorobenzamido-N-ethylamino-maleimide ((18)F-FBEM)-labeled leukocytes was performed to assess metabolic activity and leukocyte recruitment, respectively. In bleomycin-treated mice, a higher metabolic activity was measured on (18)F-FDG PET/CT scans from day 7 to day 24 after instillation, with a peak of activity measured at day 14. Of note, lung mean standardized uptake values correlated with bleomycin doses, histologic score of fibrosis, lung hydroxyproline content, and weight loss. Moreover, during the inflammatory phase of the model (day 7), but not the fibrotic phase (day 23), bleomycin-treated mice presented with an enhanced leukocyte recruitment as assessed by (18)F-FBEM-labeled leukocyte PET/CT. Autoradiographic analysis of lung sections and CD45 immunostaining confirm the higher and early recruitment of leukocytes in bleomycin-treated mice, compared with control mice. (18)F-FDG- and (18)F-FBEM-labeled leukocyte PET/CT enable monitoring of metabolic activity and leukocyte recruitment in a mouse model of pulmonary fibrosis. Implications for preclinical evaluation of antifibrotic therapy are expected. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  1. Synthesis of a Potent Aminopyridine-Based nNOS-Inhibitor by Two Recent No-Carrier-Added (18)F-Labelling Methods.

    PubMed

    Drerup, Christian; Ermert, Johannes; Coenen, Heinz H

    2016-09-01

    Nitric oxide (NO), an important multifunctional signaling molecule, is produced by three isoforms of NO-synthase (NOS) and has been associated with neurodegenerative disorders. Selective inhibitors of the subtypes iNOS (inducible) or nNOS (neuronal) are of great interest for decoding neurodestructive key factors, and (18)F-labelled analogues would allow investigating the NOS-function by molecular imaging with positron emission tomography. Especially, the highly selective nNOS inhibitor 6-((3-((3-fluorophenethylamino)methyl)phenoxy)methyl)-4-methylpyridin-2-amine (10) lends itself as suitable compound to be (18)F-labelled in no-carrier-added (n.c.a.) form. For preparation of the (18)F-labelled nNOS-Inhibitor [(18)F]10 a "build-up" radiosynthesis was developed based on a corresponding iodonium ylide as labelling precursor. The such activated phenethyl group of the compound was efficiently and regioselectively labelled with n.c.a. [(18)F]fluoride in 79% radiochemical yield (RCY). After conversion by reductive amination and microwave assisted displacement of the protecting groups, the desired nNOS-inhibitor was obtained in about 15% total RCY. Alternatively, for a simplified "late-stage" (18)F-labelling procedure a corresponding boronic ester precursor was synthesized and successfully used in a newer, copper(II) mediated n.c.a. (18)F-fluoro-deboroniation reaction, achieving the same total RCY. Thus, both methods proved comparatively suited to provide the highly selective NOS-inhibitor [(18)F]10 as probe for preclinical in vivo studies.

  2. Comparison of Two Site-Specifically 18F-Labeled Affibodies for PET Imaging of EGFR Positive Tumors

    DOE PAGES

    Su, Xinhui; Cheng, Kai; Jeon, Jongho; ...

    2014-06-27

    The epidermal growth factor receptor (EGFR) serves as an attractive target for cancer molecular imaging and therapy. Our previous positron emission tomography (PET) studies showed that the EGFR-targeting affibody molecules 64Cu-DOTA-Z EGFR:1907 and 18F-FBEM-Z EGFR:1907 can discriminate between high and low EGFR-expression tumors and have the potential for patient selection for EGFR-targeted therapy. Compared with 64Cu, 18F may improve imaging of EGFR-expression and is more suitable for clinical application, but the labeling reaction of 18F-FBEM-Z EGFR:1907 requires a long synthesis time. The aim of the present study is to develop a new generation of 18F labeled affibody probes (Al 18F-NOTA-Zmore » EGFR:1907 and 18F-CBT-Z EGFR:1907) and to determine whether they are suitable agents for imaging of EGFR expression. The first approach consisted of conjugating Z EGFR:1907 with NOTA and radiolabeling with Al 18F to produce Al 18F-NOTA-Z EGFR:1907. In a second approach the prosthetic group 18F-labeled-2-cyanobenzothiazole ( 18F-CBT) was conjugated to Cys-Z EGFR:1907 to produce 18F-CBT-Z EGFR:1907. Binding affinity and specificity of Al 18F-NOTA-Z EGFR:1907 and 18F-CBT-Z EGFR:1907 to EGFR were evaluated using A431 cells. Biodistribution and PET studies were conducted on mice bearing A431 xenografts after injection of Al 18F-NOTA-Z EGFR:1907 or 18F-CBT-Z EGFR:1907 with or without coinjection of unlabeled affibody proteins. The radiosyntheses of Al 18F-NOTA-Z EGFR:1907 and 18F-CBT-Z EGFR:1907 were completed successfully within 40 and 120 min with a decay-corrected yield of 15% and 41% using a 2-step, 1-pot reaction and 2-step, 2-pot reaction, respectively. Both probes bound to EGFR with low nanomolar affinity in A431 cells. Although 18F-CBT-Z EGFR:1907 showed instability in vivo, biodistribution studies revealed rapid and high tumor accumulation and quick clearance from normal tissues except the bones. In contrast, Al 18F-NOTA-Z EGFR:1907 demonstrated high in vitro and in

  3. Comparison of Two Site-Specifically 18F-Labeled Affibodies for PET Imaging of EGFR Positive Tumors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Su, Xinhui; Cheng, Kai; Jeon, Jongho

    The epidermal growth factor receptor (EGFR) serves as an attractive target for cancer molecular imaging and therapy. Our previous positron emission tomography (PET) studies showed that the EGFR-targeting affibody molecules 64Cu-DOTA-Z EGFR:1907 and 18F-FBEM-Z EGFR:1907 can discriminate between high and low EGFR-expression tumors and have the potential for patient selection for EGFR-targeted therapy. Compared with 64Cu, 18F may improve imaging of EGFR-expression and is more suitable for clinical application, but the labeling reaction of 18F-FBEM-Z EGFR:1907 requires a long synthesis time. The aim of the present study is to develop a new generation of 18F labeled affibody probes (Al 18F-NOTA-Zmore » EGFR:1907 and 18F-CBT-Z EGFR:1907) and to determine whether they are suitable agents for imaging of EGFR expression. The first approach consisted of conjugating Z EGFR:1907 with NOTA and radiolabeling with Al 18F to produce Al 18F-NOTA-Z EGFR:1907. In a second approach the prosthetic group 18F-labeled-2-cyanobenzothiazole ( 18F-CBT) was conjugated to Cys-Z EGFR:1907 to produce 18F-CBT-Z EGFR:1907. Binding affinity and specificity of Al 18F-NOTA-Z EGFR:1907 and 18F-CBT-Z EGFR:1907 to EGFR were evaluated using A431 cells. Biodistribution and PET studies were conducted on mice bearing A431 xenografts after injection of Al 18F-NOTA-Z EGFR:1907 or 18F-CBT-Z EGFR:1907 with or without coinjection of unlabeled affibody proteins. The radiosyntheses of Al 18F-NOTA-Z EGFR:1907 and 18F-CBT-Z EGFR:1907 were completed successfully within 40 and 120 min with a decay-corrected yield of 15% and 41% using a 2-step, 1-pot reaction and 2-step, 2-pot reaction, respectively. Both probes bound to EGFR with low nanomolar affinity in A431 cells. Although 18F-CBT-Z EGFR:1907 showed instability in vivo, biodistribution studies revealed rapid and high tumor accumulation and quick clearance from normal tissues except the bones. In contrast, Al 18F-NOTA-Z EGFR:1907 demonstrated high in vitro and in

  4. F-18 Labeled Diabody-Luciferase Fusion Proteins for Optical-ImmunoPET

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, Anna M.

    2013-01-18

    The goal of the proposed work is to develop novel dual-labeled molecular imaging probes for multimodality imaging. Based on small, engineered antibodies called diabodies, these probes will be radioactively tagged with Fluorine-18 for PET imaging, and fused to luciferases for optical (bioluminescence) detection. Performance will be evaluated and validated using a prototype integrated optical-PET imaging system, OPET. Multimodality probes for optical-PET imaging will be based on diabodies that are dually labeled with 18F for PET detection and fused to luciferases for optical imaging. 1) Two sets of fusion proteins will be built, targeting the cell surface markers CEA or HER2.more » Coelenterazine-based luciferases and variant forms will be evaluated in combination with native substrate and analogs, in order to obtain two distinct probes recognizing different targets with different spectral signatures. 2) Diabody-luciferase fusion proteins will be labeled with 18F using amine reactive [18F]-SFB produced using a novel microwave-assisted, one-pot method. 3) Sitespecific, chemoselective radiolabeling methods will be devised, to reduce the chance that radiolabeling will inactivate either the target-binding properties or the bioluminescence properties of the diabody-luciferase fusion proteins. 4) Combined optical and PET imaging of these dual modality probes will be evaluated and validated in vitro and in vivo using a prototype integrated optical-PET imaging system, OPET. Each imaging modality has its strengths and weaknesses. Development and use of dual modality probes allows optical imaging to benefit from the localization and quantitation offered by the PET mode, and enhances the PET imaging by enabling simultaneous detection of more than one probe.« less

  5. A New F-18 Labeled PET Agent For Imaging Alzheimer's Plaques

    NASA Astrophysics Data System (ADS)

    Kulkarni, Padmakar V.; Vasdev, Neil; Hao, Guiyang; Arora, Veera; Long, Michael; Slavine, Nikolai; Chiguru, Srinivas; Qu, Bao Xi; Sun, Xiankai; Bennett, Michael; Antich, Peter P.; Bonte, Frederick J.

    2011-06-01

    Amyloid plaques and neurofibrillary tangles are hallmarks of Alzheimer's disease (AD). Advances in development of imaging agents have focused on targeting amyloid plaques. Notable success has been the development of C-11 labeled PIB (Pittsburgh Compound) and a number of studies have demonstrated the utility of this agent. However, the short half life of C-11 (t1/2: 20 min), is a limitation, thus has prompted the development of F-18 labeled agents. Most of these agents are derivatives of amyloid binding dyes; Congo red and Thioflavin. Some of these agents are in clinical trials with encouraging results. We have been exploring new class of agents based on 8-hydroxy quinoline, a weak metal chelator, targeting elevated levels of metals in plaques. Iodine-123 labeled clioquinol showed affinity for amyloid plaques however, it had limited brain uptake and was not successful in imaging in intact animals and humans. We have been successful in synthesizing F-18 labeled 8-hydroxy quinoline. Small animal PET/CT imaging studies with this agent showed high (7-10% ID/g), rapid brain uptake and fast washout of the agent from normal mice brains and delayed washout from transgenic Alzheimer's mice. These promising results encouraged us in further evaluation of this class of compounds for imaging AD plaques.

  6. Synthesis and evaluation of novel 18 F-labeled quinazoline derivatives with low lipophilicity for tumor PET imaging.

    PubMed

    Chong, Yan; Chang, Jin; Zhao, Wenwen; He, Yong; Li, Yuqiao; Zhang, Huabei; Qi, Chuanmin

    2018-02-01

    Four novel 18 F-labeled quinazoline derivatives with low lipophilicity, [ 18 F]4-(2-fluoroethoxy)-6,7-dimethoxyquinazoline ([ 18 F]I), [ 18 F]4-(3-((4-(2-fluoroethoxy)-7-methoxyquinazolin-6-yl)oxy)propyl)morpholine ([ 18 F]II), [ 18 F]4-(2-fluoroethoxy)-7-methoxy-6-(2-methoxyethoxy)quinazoline ([ 18 F]III), and [ 18 F]4-(2-fluoroethoxy)-6,7-bis(2-methoxyethoxy)quinazoline ([ 18 F]IV), were synthesized via a 2-step radiosynthesis procedure with an overall radiochemical yield of 10% to 38% (without decay correction) and radiochemical purities of >98%. The lipophilicity and stability of labeled compounds were tested in vitro. The log P values of the 4 radiotracers ranged from 0.52 to 1.07. We then performed ELISA to measure their affinities to EGFR-TK; ELISA assay results indicated that each inhibitor was specifically bounded to EGFR-TK in a dose-dependent manner. The EGFR-TK autophosphorylation IC 50 values of [ 18 F]I, [ 18 F]II, [ 18 F]III, and [ 18 F]IV were 7.732, 0.4698, 0.1174, and 0.1176 μM, respectively. All labeled compounds were evaluated via cellular uptake and blocking studies in HepG2 cell lines in vitro. Cellular uptake and blocking experiment results indicated that [ 18 F]I and [ 18 F]III had excellent cellular uptake at 120-minute postinjection in HepG2 carcinoma cells (51.80 ± 3.42%ID/mg protein and 27.31 ± 1.94%ID/mg protein, respectively). Additionally, biodistribution experiments in S180 tumor-bearing mice in vivo indicated that [ 18 F]I had a very fast clearance in blood and a relatively high uptake ratio of tumor to blood (4.76) and tumor to muscle (1.82) at 60-minute postinjection. [ 18 F]III had a quick clearance in plasma, and its highest uptake ratio of tumor to muscle was 2.55 at 15-minute postinjection. These experimental results and experiences were valuable for the further exploration of novel radiotracers of quinazoline derivatives. Copyright © 2017 John Wiley & Sons, Ltd.

  7. F-18 labelled PSMA-1007: biodistribution, radiation dosimetry and histopathological validation of tumor lesions in prostate cancer patients.

    PubMed

    Giesel, Frederik L; Hadaschik, B; Cardinale, J; Radtke, J; Vinsensia, M; Lehnert, W; Kesch, C; Tolstov, Y; Singer, S; Grabe, N; Duensing, S; Schäfer, M; Neels, O C; Mier, W; Haberkorn, U; Kopka, K; Kratochwil, C

    2017-04-01

    The prostate-specific membrane antigen (PSMA) targeted positron-emitting-tomography (PET) tracer 68 Ga-PSMA-11 shows great promise in the detection of prostate cancer. However, 68 Ga has several shortcomings as a radiolabel including short half-life and non-ideal energies, and this has motivated consideration of 18 F-labelled analogs. 18 F-PSMA-1007 was selected among several 18 F-PSMA-ligand candidate compounds because it demonstrated high labelling yields, outstanding tumor uptake and fast, non-urinary background clearance. Here, we describe the properties of 18 F-PSMA-1007 in human volunteers and patients. Radiation dosimetry of 18 F-PSMA-1007 was determined in three healthy volunteers who underwent whole-body PET-scans and concomitant blood and urine sampling. Following this, ten patients with high-risk prostate cancer underwent 18 F-PSMA-1007 PET/CT (1 h and 3 h p.i.) and normal organ biodistribution and tumor uptakes were examined. Eight patients underwent prostatectomy with extended pelvic lymphadenectomy. Uptake in intra-prostatic lesions and lymph node metastases were correlated with final histopathology, including PSMA immunostaining. With an effective dose of approximately 4.4-5.5 mSv per 200-250 MBq examination, 18 F-PSMA-1007 behaves similar to other PSMA-PET agents as well as to other 18 F-labelled PET-tracers. In comparison to other PSMA-targeting PET-tracers, 18 F-PSMA-1007 has reduced urinary clearance enabling excellent assessment of the prostate. Similar to 18 F-DCFPyL and with slightly slower clearance kinetics than PSMA-11, favorable tumor-to-background ratios are observed 2-3 h after injection. In eight patients, diagnostic findings were successfully validated by histopathology. 18 F-PSMA-1007 PET/CT detected 18 of 19 lymph node metastases in the pelvis, including nodes as small as 1 mm in diameter. 18 F-PSMA-1007 performs at least comparably to 68 Ga-PSMA-11, but its longer half-life combined with its superior energy characteristics and

  8. Efficient 18F-Labeling of Large 37-Amino Acid pHLIP Peptide Analogues and their Biological Evaluation

    PubMed Central

    Daumar, Pierre; Wanger-Baumann, Cindy A.; Pillarsetty, NagaVaraKishore; Fabrizio, Laura; Carlin, Sean D.; Andreev, Oleg A.; Reshetnyak, Yana K.; Lewis, Jason S.

    2012-01-01

    Solid tumors often develop an acidic microenvironment, which plays a critical role in tumor progression and is associated with increased level of invasion and metastasis. The 37-residue pH (low) insertion peptide (pHLIP®) is under study as an imaging platform because of its unique ability to insert into cell membranes at a low extracellular pH (pHe<7). Labeling of peptides with [18F]-fluorine is usually performed via prosthetic groups using chemoselective coupling reactions. One of the most successful procedures involves the alkyne-azide copper(I) catalyzed cycloaddition (CuAAC). However, none of the known “click” methods have been applied to peptides as large as pHLIP. We designed a novel prosthetic group and extended the use of the CuAAC “click chemistry” for the simple and efficient 18F-labeling of large peptides. For the evaluation of this labeling approach, a D-amino acid analogue of WT-pHLIP and a L-amino acid control peptide K-pHLIP, both functionalized at the N-terminus with 6-azidohexanoic acid, were used. The novel 6-[18F]fluoro-2-ethynylpyridine prosthetic group, was obtained via nucleophilic substitution on the corresponding bromo-precursor after 10 min at 130 °C with a radiochemical yield of 27.5 ± 6.6% (decay corrected) with high radiochemical purity ≥ 98%. The subsequent CuI catalyzed “click” reaction with the azido functionalized pHLIP peptides was quantitative within 5 min at 70 °C in a mixture of water and ethanol using Cu-acetate and sodium L-ascorbate. [18F]-D-WT-pHLIP and [18F]-L-K-pHLIP were obtained with total radiochemical yields of 5–20% after HPLC purification. The total reaction time was only 85 min including formulation. In vitro stability tests revealed high stability of the [18F]-D-WT-pHLIP in human and mouse plasma after 120 min, with the parent tracer remaining intact at 65 and 85%, respectively. PET imaging and biodistribution studies in LNCaP and PC-3 xenografted mice with the [18F]-D-WT-pHLIP and the negative

  9. The Label Matters: μPET Imaging of the Biodistribution of Low Molar Mass 89Zr and 18F-Labeled Poly(2-ethyl-2-oxazoline).

    PubMed

    Glassner, Mathias; Palmieri, Luca; Monnery, Bryn D; Verbrugghen, Thomas; Deleye, Steven; Stroobants, Sigrid; Staelens, Steven; Wyffels, Leonie; Hoogenboom, Richard

    2017-01-09

    Poly(2-alkyl-2-oxazoline)s (PAOx) have received increasing interest for biomedical applications. Therefore, it is of fundamental importance to gain an in-depth understanding of the biodistribution profile of PAOx. We report the biodistribution of poly(2-ethyl-2-oxazoline) (PEtOx) with a molar mass of 5 kDa radiolabeled with PET isotopes 89 Zr and 18 F. 18 F-labeled PEtOx is prepared by the strain-promoted azide-alkyne cycloaddition (SPAAC) of [ 18 F]fluoroethylazide to bicyclo[6.1.0]non-4-yne (BCN)-functionalized PEtOx as many common labeling strategies were found to be unsuccessful for PEtOx. 89 Zr-labeled PEtOx is prepared using desferrioxamine end-groups as a chelator. Five kDa PEtOx shows a significantly faster blood clearance compared to PEtOx of higher molar mass while uptake in the liver is lower, indicating a minor contribution of the liver in excretion of the 5 kDa PEtOx. While [ 18 F]-PEtOx displays a rapid and efficient clearance from the kidneys, 5 kDa [ 89 Zr]-Df-PEtOx is not efficiently cleared over the time course of the study, which is most likely caused by trapping of 89 Zr-labeled metabolites in the renal tubules and not the polymer itself, demonstrating the importance of selecting the appropriate label for biodistribution studies.

  10. Fluorine-18 Radiochemistry, Labeling Strategies and Synthetic Routes

    PubMed Central

    2015-01-01

    Fluorine-18 is the most frequently used radioisotope in positron emission tomography (PET) radiopharmaceuticals in both clinical and preclinical research. Its physical and nuclear characteristics (97% β+ decay, 109.7 min half-life, 635 keV positron energy), along with high specific activity and ease of large scale production, make it an attractive nuclide for radiochemical labeling and molecular imaging. Versatile chemistry including nucleophilic and electrophilic substitutions allows direct or indirect introduction of 18F into molecules of interest. The significant increase in 18F radiotracers for PET imaging accentuates the need for simple and efficient 18F-labeling procedures. In this review, we will describe the current radiosynthesis routes and strategies for 18F labeling of small molecules and biomolecules. PMID:25473848

  11. Imaging infection with 18F-FDG-labeled leukocyte PET/CT: initial experience in 21 patients.

    PubMed

    Dumarey, Nicolas; Egrise, Dominique; Blocklet, Didier; Stallenberg, Bernard; Remmelink, Myriam; del Marmol, Véronique; Van Simaeys, Gaëtan; Jacobs, Frédérique; Goldman, Serge

    2006-04-01

    The aim of this study was to assess the feasibility and the potential role of PET/CT with (18)F-FDG-labeled autologous leukocytes in the diagnosis and localization of infectious lesions. Twenty-one consecutive patients with suspected or documented infection were prospectively evaluated with whole-body PET/CT 3 h after injection of autologous (18)F-FDG-labeled leukocytes. Two experienced nuclear medicine physicians who were unaware of the clinical end-diagnosis reviewed all PET/CT studies. A visual score (0-3)-according to uptake intensity-was used to assess studies. The results of PET/CT with (18)F-FDG-labeled white blood cell ((18)F-FDG-WBC) assessment were compared with histologic or biologic diagnosis in 15 patients and with clinical end-diagnosis after complete clinical work-up in 6 patients. Nine patients had fever of unknown etiology, 6 patients had documented infection but with unknown extension of the infectious disease, 4 patients had a documented infection with unfavorable evolution, and 2 patients had a documented infection with known extension. The best trade-off between sensitivity and specificity was obtained when a visual score of >or=2 was chosen to identify increased tracer uptake as infection. With this threshold, sensitivity, specificity, and accuracy were each 86% on a patient-per-patient basis and 91%, 85%, and 90% on a lesion-per-lesion basis. In this small group of patients, the absence of areas with increased WBC uptake on WBC PET/CT had a 100% negative predictive value. Hybrid (18)F-FDG-WBC PET/CT was found to have a high sensitivity and specificity for the diagnosis of infection. It located infectious lesions with a high precision. In this small series, absence of areas with increased uptake virtually ruled out the presence of infection. (18)F-FDG-WBC PET/CT for infection detection deserves further investigation in a larger prospective series.

  12. 18F-FDG labeling of mesenchymal stem cells and multipotent adult progenitor cells for PET imaging: effects on ultrastructure and differentiation capacity.

    PubMed

    Wolfs, Esther; Struys, Tom; Notelaers, Tineke; Roberts, Scott J; Sohni, Abhishek; Bormans, Guy; Van Laere, Koen; Luyten, Frank P; Gheysens, Olivier; Lambrichts, Ivo; Verfaillie, Catherine M; Deroose, Christophe M

    2013-03-01

    Because of their extended differentiation capacity, stem cells have gained great interest in the field of regenerative medicine. For the development of therapeutic strategies, more knowledge on the in vivo fate of these cells has to be acquired. Therefore, stem cells can be labeled with radioactive tracer molecules such as (18)F-FDG, a positron-emitting glucose analog that is taken up and metabolically trapped by the cells. The aim of this study was to optimize the radioactive labeling of mesenchymal stem cells (MSCs) and multipotent adult progenitor cells (MAPCs) in vitro with (18)F-FDG and to investigate the potential radiotoxic effects of this labeling procedure with a range of techniques, including transmission electron microscopy (TEM). Mouse MSCs and rat MAPCs were used for (18)F-FDG uptake kinetics and tracer retention studies. Cell metabolic activity, proliferation, differentiation and ultrastructural changes after labeling were evaluated using an Alamar Blue reagent, doubling time calculations and quantitative TEM, respectively. Additionally, mice were injected with MSCs and MAPCs prelabeled with (18)F-FDG, and stem cell biodistribution was investigated using small-animal PET. The optimal incubation period for (18)F-FDG uptake was 60 min. Significant early tracer washout was observed, with approximately 30%-40% of the tracer being retained inside the cells 3 h after labeling. Cell viability, proliferation, and differentiation capacity were not severely affected by (18)F-FDG labeling. No major changes at the ultrastructural level, considering mitochondrial length, lysosome size, the number of lysosomes, the number of vacuoles, and the average rough endoplasmic reticulum width, were observed with TEM. Small-animal PET experiments with radiolabeled MAPCs and MSCs injected intravenously in mice showed a predominant accumulation in the lungs and a substantial elution of (18)F-FDG from the cells. MSCs and MAPCs can be successfully labeled with (18)F-FDG for

  13. Novel 18F-Labeled κ-Opioid Receptor Antagonist as PET Radiotracer: Synthesis and In Vivo Evaluation of 18F-LY2459989 in Nonhuman Primates.

    PubMed

    Li, Songye; Cai, Zhengxin; Zheng, Ming-Qiang; Holden, Daniel; Naganawa, Mika; Lin, Shu-Fei; Ropchan, Jim; Labaree, David; Kapinos, Michael; Lara-Jaime, Teresa; Navarro, Antonio; Huang, Yiyun

    2018-01-01

    The κ-opioid receptor (KOR) has been implicated in depression, addictions, and other central nervous system disorders and, thus, is an important target for drug development. We previously developed several 11 C-labeled PET radiotracers for KOR imaging in humans. Here we report the synthesis and evaluation of 18 F-LY2459989 as the first 18 F-labeled KOR antagonist radiotracer in nonhuman primates and its comparison with 11 C-LY2459989. Methods: The novel radioligand 18 F-LY2459989 was synthesized by 18 F displacement of a nitro group or an iodonium ylide. PET scans in rhesus monkeys were obtained on a small-animal scanner to assess the pharmacokinetic and in vivo binding properties of the ligand. Metabolite-corrected arterial activity curves were measured and used as input functions in the analysis of brain time-activity curves and the calculation of binding parameters. Results: With the iodonium ylide precursor, 18 F-LY2459989 was prepared at high radiochemical yield (36% ± 7% [mean ± SD]), radiochemical purity (>99%), and mean molar activity (1,175 GBq/μmol; n = 6). In monkeys, 18 F-LY2459989 was metabolized at a moderate rate, with a parent fraction of approximately 35% at 30 min after injection. Fast and reversible kinetics were observed, with a regional peak uptake time of less than 20 min. Pretreatment with the selective KOR antagonist LY2456302 (0.1 mg/kg) decreased the activity level in regions with high levels of binding to that in the cerebellum, thus demonstrating the binding specificity and selectivity of 18 F-LY2459989 in vivo. Regional time-activity curves were well fitted by the multilinear analysis 1 kinetic model to derive reliable estimates of regional distribution volumes. With the cerebellum as the reference region, regional binding potentials were calculated and ranked as follows: cingulate cortex > insula > caudate/putamen > frontal cortex > temporal cortex > thalamus, consistent with the reported KOR distribution in the monkey brain

  14. Magnetic Droplet Microfluidics as a Platform for the Concentration of [18F]Fluoride and Radiosynthesis of Sulfonyl [18F]Fluoride.

    PubMed

    Fiel, Somewhere A; Yang, Hua; Schaffer, Paul; Weng, Samuel; Inkster, James A H; Wong, Michael C K; Li, Paul C H

    2015-06-17

    The radioisotope 18F is often considered the best choice for positron emission tomography (PET) owing to its desirable chemical and radiochemical properties. However, nucleophilic 18F-fluorination of large, water-soluble biomolecules, based on C-F bond formation, has traditionally been difficult. Thus, several aqueous fluorination approaches that offer significant versatility in radiopharmaceutical synthesis with sensitive targeting vectors have been developed. Furthermore, because 18F decays rapidly, production of these 18F-labeled compounds requires an automated process to reduce production time, reduce radiation exposure, and minimize losses due to the transfer of reagents during tracer synthesis. Herein, we report the use of magnetic droplet microfluidics (MDM) as a means to concentrate [18F]fluoride from the cyclotron target solution, followed by the synthesis of an 18F-labeled compound on a microfluidic platform. Using this method, we have demonstrated 18F preconcentration in a small-volume droplet through the use of anion exchanging magnetic particles. By using MDM, the preconcentration step took approximately 5 min, and the [18F]fluoride solution was preconcentrated by 15-fold. After the preconcentration step, an 18F-labeling reaction was performed on the MDM platform using the S-F bond formation in aqueous conditions to produce an arylsulfonyl [18F]fluoride compound which can be used as a prosthetic group to label PET targeting ligands. The high radiochemical purity of 95±1% was comparable to the 96% previously reported using a conventional method. In addition, when MDM was used, the total synthesis time was improved to 15 min with lower reagent volumes (50-60 μL) used.

  15. Comparison of 18F-Labeled Fluoroalkylphosphonium Cations with 13N-NH3 for PET Myocardial Perfusion Imaging.

    PubMed

    Kim, Dong-Yeon; Kim, Hyeon Sik; Reder, Sybille; Zheng, Jin Hai; Herz, Michael; Higuchi, Takahiro; Pyo, A Young; Bom, Hee-Seung; Schwaiger, Markus; Min, Jung-Joon

    2015-10-01

    Despite substantial advances in the diagnosis of cardiovascular disease, there is a need for 18F-labeled myocardial perfusion agents for the diagnosis of ischemic heart disease because current PET tracers for myocardial perfusion imaging have a short half-life that limits their widespread clinical use in PET. Thus, 18F-labeled fluoroalkylphosphonium derivatives (18F-FATPs), including (5-18F-fluoropentyl)triphenylphosphonium cation (18F-FPTP), (6-18F-fluorohexyl)triphenylphosphonium cation (18F-FHTP), and (2-(2-18F-fluoroethoxy)ethyl)triphenylphosphonium cation (18F-FETP), were synthesized. The myocardial extraction and image quality of the 18F-FATPs were compared with those of 13N-NH3 in rat models. The first-pass extraction fraction (EF) values of the 18F-FATPs (18F-FPTP, 18F-FHTP, 18F-FETP) and 13N-NH3 were measured in isolated rat hearts perfused with the Langendorff method (flow velocities, 0.5, 4.0, 8.0, and 16.0 mL/min). Normal and myocardial infarction rats were imaged with small-animal PET after intravenous injection of 37 MBq of 18F-FATPs and 13N-NH3. To determine pharmacokinetics, a region of interest was drawn around the heart, and time-activity curves of the 18F-FATPs and 13N-NH3 were generated to obtain the counts per pixel per second. Defect size was analyzed on the basis of polar map images of 18F-FATPs and 13N-NH3. The EF values of 18F-FATPs and 13N-NH3 were comparable at low flow velocity (0.5 mL/min), whereas at higher flows EF values of 18F-FATPs were significantly higher than those of 13N-NH3 (4.0, 8.0, and 16.0 mL/min, P<0.05). Myocardium-to-liver ratios of 18F-FPTP, 18F-FHTP, 18F-FETP, and 13N-NH3 were 2.10±0.30, 4.36±0.20, 3.88±1.03, and 0.70±0.09, respectively, 10 min after injection, whereas myocardium-to-lung ratios were 5.00±0.25, 4.33±0.20, 7.98±1.23, and 2.26±0.14, respectively. Although 18F-FATPs and 13N-NH3 sharply delineated myocardial perfusion defects, defect size on the 13N-NH3 images was significantly smaller than on the

  16. New horizons in cardiac innervation imaging: introduction of novel 18F-labeled PET tracers.

    PubMed

    Kobayashi, Ryohei; Chen, Xinyu; Werner, Rudolf A; Lapa, Constantin; Javadi, Mehrbod S; Higuchi, Takahiro

    2017-12-01

    Cardiac sympathetic nervous activity can be uniquely visualized by non-invasive radionuclide imaging techniques due to the fast growing and widespread application of nuclear cardiology in the last few years. The norepinephrine analogue 123 I-meta-iodobenzylguanidine ( 123 I-MIBG) is a single photon emission computed tomography (SPECT) tracer for the clinical implementation of sympathetic nervous imaging for both diagnosis and prognosis of heart failure. Meanwhile, positron emission tomography (PET) imaging has become increasingly attractive because of its higher spatial and temporal resolution compared to SPECT, which allows regional functional and dynamic kinetic analysis. Nevertheless, wider use of cardiac sympathetic nervous PET imaging is still limited mainly due to the demand of costly on-site cyclotrons, which are required for the production of conventional 11 C-labeled (radiological half-life, 20 min) PET tracers. Most recently, more promising 18 F-labeled (half-life, 110 min) PET radiopharmaceuticals targeting sympathetic nervous system have been introduced. These tracers optimize PET imaging and, by using delivery networks, cost less to produce. In this article, the latest advances of sympathetic nervous imaging using 18 F-labeled radiotracers along with their possible applications are reviewed.

  17. (18)F-Fluoroglucosylation of peptides, exemplified on cyclo(RGDfK).

    PubMed

    Hultsch, Christina; Schottelius, Margret; Auernheimer, Jörg; Alke, Andrea; Wester, Hans-Jürgen

    2009-09-01

    Oxime formation between an aminooxy-functionalized peptide and an (18)F-labelled aldehyde has recently been introduced as a powerful method for the rapid one-step chemoselective synthesis of radiofluorinated peptides. Here, the potential of using routinely produced and thus readily available [(18)F]fluorodeoxyglucose ([(18)F]FDG) as the aldehydic prosthetic group was investigated using an aminooxyacetyl-conjugated cyclic RGD peptide (cyclo(RGDfK(Aoa-(Boc)) as a model peptide. The use of [(18)F]FDG from routine production ([(18)F]FDGTUM) containing an excess of D: -glucose did not allow the radiosynthesis of [(18)F]FDG-RGD in activities >37 MBq in reasonable yield, rendering the direct use of clinical grade [(18)F]FDG for the routine clinical synthesis of (18)F-labelled peptides impossible. Using no-carrier-added (n.c.a.) [(18)F]FDG obtained via HPLC separation of [(18)F]FDGTUM from excess glucose, however, afforded [(18)F]FDG-RGD in yields of 56-93% (decay corrected) and activities up to 37 MBq. Suitable reaction conditions were 20 min at 120 degrees C and pH 2.5, and a peptide concentration of 5 mM. In a preliminary in vivo biodistribution study in M21 melanoma-bearing nude mice, [(18)F]FDG-RGD showed increased tumour accumulation compared to the "gold standard" [(18)F]galacto-RGD (2.18 vs 1.49 %iD/g, respectively, at 120 min after injection), but also slightly increased uptake in non-target organs, leading to comparable tumour/organ ratios for both compounds. These data demonstrate that chemoselective (18)F-labelling of aminooxy-functionalized peptides using n.c.a. [(18)F]FDG represents a radiofluorination/glycosylation strategy that allows preparation of (18)F-labelled peptides in high yield with suitable pharmacokinetics. As soon as the necessary n.c.a. preparation of [(18)F]FDG prior to reaction with the Aoa-peptide can be implemented in a fully automated [(18)F]FDG-synthesis, [(18)F]fluoroglucosylation of peptides may represent a promising alternative to

  18. The Effect of the Prosthetic Group on the Pharmacologic Properties of 18F-labeled Rhodamine B, a Potential Myocardial Perfusion Agent for PET

    PubMed Central

    Bartholomä, Mark D.; Gottumukkala, Vijay; Zhang, Shaohui; Baker, Amanda; Dunning, Patricia; Fahey, Frederic H.; Treves, S. Ted; Packard, Alan B.

    2013-01-01

    We recently reported the development of the 2-[18F]fluoroethyl ester of rhodamine B as a potential positron emission tomography (PET) tracer for myocardial perfusion imaging. This compound, which was prepared using a [18F]fluoroethyl prosthetic group, has significant uptake in the myocardium in rats, but also demonstrates relatively high liver uptake and is rapidly hydrolyzed in vivo in mice. We have now prepared 18F-labeled rhodamine B using three additional prosthetic groups (propyl, diethylene glycol, and triethylene glycol) and found that the prosthetic group has a significant effect on the in vitro and in vivo properties of these compounds. Of the esters prepared to date, the diethylene glycol ester is superior in terms of in vitro stability and pharmacokinetics. These observations suggest that the prosthetic group plays a significant role in determining the pharmacological properties of 18F-labeled compounds. They also support the value of continued investigation of 18F-labeled rhodamines as PET radiopharmaceuticals for myocardial perfusion imaging. PMID:23210516

  19. Automated synthesis of 4-[(18)F]fluoroanisole, [(18)F]DAA1106 and 4-[(18)F]FPhe using Cu-mediated radiofluorination under "minimalist" conditions.

    PubMed

    Zischler, Johannes; Krapf, Philipp; Richarz, Raphael; Zlatopolskiy, Boris D; Neumaier, Bernd

    2016-09-01

    The application of the "minimalist" approach to Cu-mediated radiofluorination allows the efficient preparation of (18)F-labeled arenes regardless of their electronic properties. The implementation of this methodology on a commercially available synthesis module (hotbox(three), Scintomics, Germany) enabled the automated production of 4-[(18)F]fluoroanisole as well as the clinically relevant PET-tracers, 4-[(18)F]FPhe and [(18)F]DAA1106, in radiochemical yields of 41-61% and radiochemical purities of >95% within 30-60min. These results demonstrated the high efficacy and versatility of the developed method that will open up opportunities for a broad application of Cu-mediated radiofluorination in PET-chemistry. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Targeting Prostate-Specific Membrane Antigen (PSMA) with F-18-Labeled Compounds: the Influence of Prosthetic Groups on Tumor Uptake and Clearance Profile.

    PubMed

    Bouvet, Vincent; Wuest, Melinda; Bailey, Justin J; Bergman, Cody; Janzen, Nancy; Valliant, John F; Wuest, Frank

    2017-12-01

    Prostate-specific membrane antigen (PSMA) is an important biomarker expressed in the majority of prostate cancers. The favorable positron emission tomography (PET) imaging profile of the PSMA imaging agent 2-(3-(1-carboxy-5-[(6-[ 18 F]fluoro-pyridine-3-carbonyl)-amino]-pentyl)-ureido)-pentane-dioic acid [ 18 F]DCFPyL in preclinical prostate cancer models and in prostate cancer patients stimulated the development and validation of other fluorine-containing PSMA inhibitors to further enhance pharmacokinetics and simplify production methods. Here, we describe the synthesis and radiopharmacological evaluation of various F-18-labeled PSMA inhibitors which were prepared through different prosthetic group chemistry strategies. Prosthetic groups N-succinimidyl-4-[ 18 F]fluorobenzoate ([ 18 F]SFB), 4-[ 18 F]fluorobenzaldehyde, and 2-deoxy-2-[ 18 F]fluoro-D-glucose ([ 18 F]FDG) were used for bioconjugation reactions to PSMA-binding lysine-urea-glutamate scaffold via acylation and oxime formation. All fluorine-containing PSMA inhibitors were tested for their PSMA inhibitory potency in an in vitro competitive binding assay in comparison to an established reference compound [ 125 I]TAAG-PSMA. Tumor uptake and clearance profiles of three F-18-labeled PSMA inhibitors ([ 18 F]4, [ 18 F]7, and [ 18 F]8) were studied with dynamic PET imaging using LNCaP tumor-bearing mice. F-18-labeled PSMA inhibitors were synthesized in 32-69 % radiochemical yields using (1) acylation reaction at the primary amino group of the lysine residue with [ 18 F]SFB and (2) oxime formation with 4-[ 18 F]fluorobenzaldehyde and [ 18 F]FDG using the respective aminooxy-functionalized lysine residue. Compound 7 displayed an IC 50 value of 6 nM reflecting very high affinity for PSMA. Compounds 4 and 8 showed IC 50 values of 13 and 62 nM, respectively. The IC 50 value of reference compound DCFPyL was 13 nM. Dynamic PET imaging revealed the following SUV 60min for radiotracer uptake in PSMA(+) LNCaP tumors: 0

  1. Effect of the prosthetic group on the pharmacologic properties of 18F-labeled rhodamine B, a potential myocardial perfusion agent for positron emission tomography (PET).

    PubMed

    Bartholomä, Mark D; Gottumukkala, Vijay; Zhang, Shaohui; Baker, Amanda; Dunning, Patricia; Fahey, Frederic H; Treves, S Ted; Packard, Alan B

    2012-12-27

    We recently reported the development of the 2-[(18)F]fluoroethyl ester of rhodamine B as a potential positron emission tomography (PET) tracer for myocardial perfusion imaging. This compound, which was prepared using a [(18)F]fluoroethyl prosthetic group, has significant uptake in the myocardium in rats but also demonstrates relatively high liver uptake and is rapidly hydrolyzed in vivo in mice. We have now prepared (18)F-labeled rhodamine B using three additional prosthetic groups (propyl, diethylene glycol, and triethylene glycol) and found that the prosthetic group has a significant effect on the in vitro and in vivo properties of these compounds. Of the esters prepared to date, the diethylene glycol ester is superior in terms of in vitro stability and pharmacokinetics. These observations suggest that the prosthetic group plays a significant role in determining the pharmacological properties of (18)F-labeled compounds. They also support the value of continued investigation of (18)F-labeled rhodamines as PET radiopharmaceuticals for myocardial perfusion imaging.

  2. Synthesis and Monkey-PET Study of (R)- and (S)-18F-Labeled 2-Arylbenzoheterocyclic Derivatives as Amyloid Probes with Distinctive in Vivo Kinetics.

    PubMed

    Yang, Yanping; Wang, Xuedan; Yang, Hui; Fu, Hualong; Zhang, Jinming; Zhang, Xiaojun; Dai, Jiapei; Zhang, Zhiyong; Lin, Chunping; Guo, Yuzhi; Cui, Mengchao

    2016-11-07

    This study describes an effective strategy to improve pharmacokinetics of Aβ imaging agents, offering a novel class of (R)- and (S)- 18 F-labeled 2-arylbenzoheterocyclic derivatives which bear an additional chiral hydroxyl group on the side chain. These ligands displayed binding abilities toward Aβ aggregates with K i values ranging from 3.2 to 195.6 nM. Chirality-related discrepancy was observed in biodistribution, and (S)-2-phenylbenzoxazole enantiomers exhibited vastly improved brain clearance with washout ratios higher than 20. Notably, (S)-[ 18 F]28 possessed high binding potency (K i = 7.6 nM) and exceptional brain kinetics (9.46% ID/g at 2 min, brain 2min /brain 60min = 27.8) that is superior to well-established [ 18 F]AV45. The excellent pharmacokinetics and low nonspecific binding of (S)-[ 18 F]28 were testified by dynamic PET/CT scans in monkey brains. In addition, (S)-[ 18 F]28 clearly labeled Aβ plaques both in vitro and ex vivo. These results might qualify (S)-[ 18 F]28 to detect Aβ plaques with high signal-to-noise ratio.

  3. Biocompatible inorganic nanoparticles for [18F]-fluoride binding with applications in PET imaging

    PubMed Central

    Jauregui-Osoro, Maite; Williamson, Peter A.; Glaria, Arnaud; Sunassee, Kavitha; Charoenphun, Putthiporn; Green, Mark A.; Mullen, Gregory E. D.; Blower, Philip J.

    2014-01-01

    A wide selection of insoluble nanoparticulate metal salts was screened for avid binding of [18F]-fluoride. Hydroxyapatite and aluminium hydroxide nanoparticles showed particularly avid and stable binding of [18F]-fluoride in various biological media. The in vivo behaviour of the [18F]-labelled hydroxyapatite and aluminium hydroxide particles was determined by PET-CT imaging in mice. [18F]-labelled hydroxyapatite was stable in circulation and when trapped in various tissues (lung embolisation, subcutaneous and intramuscular), but accumulation in liver via reticuloendothelial clearance was followed by gradual degradation and release of [18F]-fluoride (over a period of 4 h) which accumulated in bone. [18F]-labelled aluminium hydroxide was also cleared to liver and spleen but degraded slightly even without liver uptake (subcutanenous and intramuscular). Both materials have properties that are an attractive basis for the design of molecular targeted PET imaging agents labelled with 18F. PMID:21394352

  4. Synthesis and evaluation of an 18 F-labeled trifluoroborate derivative of 2-nitroimidazole for imaging tumor hypoxia with positron emission tomography.

    PubMed

    Nunes, Paulo Sérgio Gonçalves; Zhang, Zhengxing; Kuo, Hsiou-Ting; Zhang, Chengcheng; Rousseau, Julie; Rousseau, Etienne; Lau, Joseph; Kwon, Daniel; Carvalho, Ivone; Bénard, François; Lin, Kuo-Shyan

    2018-04-01

    2-Nitroimidazole-based hypoxia imaging tracers such as 18 F-FMISO are normally imaged at late time points (several hours post-injection) due to their slow clearance from background tissues. Here, we investigated if a hydrophilic zwitterion-based ammoniomethyl-trifluoroborate derivative of 2-nitroimidazole, 18 F-AmBF 3 -Bu-2NI, could have the potential to image tumor hypoxia at earlier time points. AmBF 3 -Bu-2NI was prepared in 4 steps. 18 F labeling was conducted via 18 F- 19 F isotope exchange reaction, and 18 F-AmBF 3 -Bu-2NI was obtained in 14.8 ± 0.4% (n = 3) decay-corrected radiochemical yield with 24.5 ± 5.2 GBq/μmol specific activity and >99% radiochemical purity. Imaging and biodistribution studies in HT-29 tumor-bearing mice showed that 18 F-AmBF 3 -Bu-2NI cleared quickly from blood and was excreted via the hepatobiliary and renal pathways. However, the tumor was not visualized in PET images until 3 hours post-injection due to low tumor uptake (0.54 ± 0.13 and 0.19 ± 0.04%ID/g at 1 and 3 hours post-injection, respectively). The low tumor uptake is likely due to the highly hydrophilic motif of ammoniomethyl-trifluoroborate that prevents free diffusion of 18 F-AmBF 3 -Bu-2NI across the cell membrane. Our results suggest that highly hydrophilic 18 F-labeled ammoniomethyl-trifluoroborate derivatives might not be suitable for imaging intracellular targets including nitroreductase, a common tumor hypoxia imaging target. Copyright © 2017 John Wiley & Sons, Ltd.

  5. Automated radiosynthesis of no-carrier-added 4-[18F]fluoroiodobenzene: a versatile building block in 18F radiochemistry.

    PubMed

    Way, Jenilee Dawn; Wuest, Frank

    2014-02-01

    4-[18F]Fluoroiodobenzene ([18F]FIB) is a versatile building block in 18F radiochemistry used in various transition metal-mediated C-C and C-N cross-coupling reactions and [18F]fluoroarylation reactions. Various synthesis routes have been described for the preparation of [18F]FIB. However, to date, no automated synthesis of [18F]FIB has been reported to allow access to larger amounts of [18F]FIB in high radiochemical and chemical purity. Herein, we describe an automated synthesis of no-carrier-added [18F]FIB on a GE TRACERlab™ FX automated synthesis unit starting from commercially available(4-iodophenyl)diphenylsulfonium triflate as the labelling precursor. [18F]FIB was prepared in high radiochemical yields of 89 ± 10% (decay-corrected, n = 7) within 60 min, including HPLC purification. The radiochemical purity exceeded 95%, and specific activity was greater than 40 GBq/μmol. Typically, from an experiment, 6.4 GBq of [18F]FIB could be obtained starting from 10.4 GBq of [18F]fluoride.

  6. (18)F-labeled positron emission tomographic radiopharmaceuticals in oncology: an overview of radiochemistry and mechanisms of tumor localization.

    PubMed

    Vallabhajosula, Shankar

    2007-11-01

    Molecular imaging is the visualization, characterization, and measurement of biological processes at the molecular and cellular levels in a living system. At present, positron emission tomography/computed tomography (PET/CT) is one the most rapidly growing areas of medical imaging, with many applications in the clinical management of patients with cancer. Although [(18)F]fluorodeoxyglucose (FDG)-PET/CT imaging provides high specificity and sensitivity in several kinds of cancer and has many applications, it is important to recognize that FDG is not a "specific" radiotracer for imaging malignant disease. Highly "tumor-specific" and "tumor cell signal-specific" PET radiopharmaceuticals are essential to meet the growing demand of radioisotope-based molecular imaging technology. In the last 15 years, many alternative PET tracers have been proposed and evaluated in preclinical and clinical studies to characterize the tumor biology more appropriately. The potential clinical utility of several (18)F-labeled radiotracers (eg, fluoride, FDOPA, FLT, FMISO, FES, and FCH) is being reviewed by several investigators in this issue. An overview of design and development of (18)F-labeled PET radiopharmaceuticals, radiochemistry, and mechanism(s) of tumor cell uptake and localization of radiotracers are presented here. The approval of clinical indications for FDG-PET in the year 2000 by the Food and Drug Administration, based on a review of literature, was a major breakthrough to the rapid incorporation of PET into nuclear medicine practice, particularly in oncology. Approval of a radiopharmaceutical typically involves submission of a "New Drug Application" by a manufacturer or a company clearly documenting 2 major aspects of the drug: (1) manufacturing of PET drug using current good manufacturing practices and (2) the safety and effectiveness of a drug with specific indications. The potential routine clinical utility of (18)F-labeled PET radiopharmaceuticals depends also on

  7. Noninvasive positron emission tomography imaging of cell death using a novel small-molecule probe, (18)F labeled bis(zinc(II)-dipicolylamine) complex.

    PubMed

    Wang, Hongliang; Tang, Xiaolan; Tang, Ganghua; Huang, Tingting; Liang, Xiang; Hu, Kongzhen; Deng, Huaifu; Yi, Chang; Shi, Xinchong; Wu, Kening

    2013-08-01

    The synthetic bis(zinc(II)-dipicolylamine) (DPAZn2) coordination complexes are known to have a high specific and selective affinity to target the exposed phosphatidylserine (PS) on the surface of dead and dying cells. An (18)F-labeled DPAZn2 complex (4-(18)F-Fluoro-benzoyl-bis(zinc(II)-dipicolylamine), (18)F-FB-DPAZn2) as positron emission tomography (PET) tracer was developed and evaluated for in vivo imaging of tumor treated with a chemical agent. The in vitro cell stain studies revealed that fluorescent DPAZn2 complexes (Dansyl-DPAZn2) stained the same cells (apoptotic and necrotic cells) as fluorescein isothiocyanate (FITC) labeled Annexin V (FITC-Annexin V). The radiosynthesis of (18)F-FB-DPAZn2 was achieved through the amidation the precursor bis(2,2'-dipicolylamine) derivative (DPA2) with the prosthetic group N-succinimidyl-4-[(18)F]-fluorobenzoate ((18)F-SFB) and chelation with zinc nitrate. In the biodistribution study, the fast clearance of (18)F-FB-DPAZn2 from blood and kidney was observed and high uptake in liver and intestine within 90 min postinjection was also found. For the PET imaging, significantly higher tumor uptake of (18)F-FB-DPAZn2 was observed in the adriamycin (ADM)-treated Hepa1-6 hepatocellular carcinoma-bearing mice than that in the untreated tumor-model mice, while a slightly decreased tumor uptake of (18)F-FDG was found in the ADM-treated tumor-bearing mice. The results indicate that (18)F-FB-DPAZn2 has the similar capability of apoptosis detection as FITC-Annexin V and seems to be a potential PET tracer for noninvasive evaluation and monitoring of anti-tumor chemotherapy. The high uptake of (18)F-FB-DPAZn2 in the abdomen needs to optimize the structure for improving its pharmacokinetics characteristics in the future work.

  8. Expedited Synthesis of Fluorine-18 Labeled Phenols. A Missing Link in PET Radiochemistry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Katzenellenbogen, John A.; Zhou, Dong

    Fluorine-18 (F-18) is arguably the most valuable radionuclide for positron emission tomographic (PET) imaging. However, while there are many methods for labeling small molecules with F-18 at aliphatic positions and on electron-deficient aromatic rings, there are essentially no reliable and practical methods to label electron-rich aromatic rings such as phenols, with F-18 at high specific activity. This is disappointing because fluorine-labeled phenols are found in many drugs; there are also many interesting plant metabolites and hormones that contain either phenols or other electron-rich aromatic systems such as indoles whose metabolism, transport, and distribution would be interesting to study if theymore » could readily be labeled with F-18. Most approaches to label phenols with F-18 involve the labeling of electron-poor precursor arenes by nucleophilic aromatic substitution, followed by subsequent conversion to phenols by oxidation or other multi-step sequences that are often inefficient and time consuming. Thus, the lack of good methods for labeling phenols and other electron-rich aromatics with F-18 at high specific activity represents a significant methodological gap in F-18 radiochemistry that can be considered a “Missing Link in PET Radiochemistry”. The objective of this research project was to develop and optimize a series of unusual synthetic transformations that will enable phenols (and other electron-rich aromatic systems) to be labeled with F-18 at high specific activity, rapidly, reliably, and conveniently, thereby bridging this gap. Through the studies conducted with support of this project, we have substantially advanced synthetic methodology for the preparation of fluorophenols. Our progress is presented in detail in the sections below, and much has been published or presented publication; other components are being prepared for publication. In essence, we have developed a completely new method to prepare o-fluorophenols from non

  9. Non-invasive glucagon-like peptide-1 receptor imaging in pancreas with (18)F-Al labeled Cys(39)-exendin-4.

    PubMed

    Mi, Baoming; Xu, Yuping; Pan, Donghui; Wang, Lizhen; Yang, Runlin; Yu, Chunjing; Wan, Weixing; Wu, Yiwei; Yang, Min

    2016-02-26

    Glucagon-like peptide-1 receptor (GLP-1R) is abundantly expressed on beta cells and may be an ideal target for the pancreas imaging. Monitoring the GLP-1R of pancreas could be benefit for understanding the pathophysiology of diabetes. In the present study, (18)F-Al labeled exendin-4 analog, (18)F-Al-NOTA-MAL-Cys(39)-exendin-4, was evaluated for PET imaging GLP-1R in the pancreas. The targeting of (18)F-Al labeled exendin-4 analog was examined in healthy and streptozotocin induced diabetic rats. Rats were injected with (18)F-Al-NOTA-MAL-Cys(39)-exendin-4 and microPET imaging was performed at 1 h postinjection, followed by ex vivo biodistribution. GLP-1R expression in pancreas was determined through post mortern examinations. The pancreas of healthy rats was readily visualized after administration of (18)F-Al-NOTA-MAL-Cys(39)-exendin-4, whereas the pancreas of diabetic rats, as well as those from rats co-injected with excess of unlabeled peptides, was barely visible by microPET. At 60 min postinjection, the pancreatic uptakes were 1.02 ± 0.15%ID/g and 0.23 ± 0.05%ID/g in healthy and diabetic rats respectively. Under block, the pancreatic uptakes of non-diabetic rats reduced to 0.21 ± 0.07%ID/g at the same time point. Biodistribution data and IHC staining confirmed the findings of the microPET imaging. The favorable preclinical data indicated that (18)F-Al-NOTA-MAL-Cys(39)-exendin-4may be suitable for non-invasive monitoring functional pancreatic beta cells. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Dual integrin and gastrin-releasing peptide receptor targeted tumor imaging using 18F-labeled PEGylated RGD-bombesin heterodimer 18F-FB-PEG3-Glu-RGD-BBN.

    PubMed

    Liu, Zhaofei; Yan, Yongjun; Chin, Frederic T; Wang, Fan; Chen, Xiaoyuan

    2009-01-22

    Radiolabeled RGD and bombesin peptides have been extensively investigated for tumor integrin alpha(v)beta(3) and GRPR imaging, respectively. Due to the fact that many tumors are both integrin and GRPR positive, we designed and synthesized a heterodimeric peptide Glu-RGD-BBN, which is expected to be advantageous over the monomeric peptides for dual-receptor targeting. A PEG(3) spacer was attached to the glutamate alpha-amino group of Glu-RGD-BBN to enhance the (18)F labeling yield and to improve the in vivo kinetics. PEG(3)-Glu-RGD-BBN possesses the comparable GRPR and integrin alpha(v)beta(3) receptor-binding affinities as the corresponding monomers, respectively. The dual-receptor targeting properties of (18)F-FB-PEG(3)-Glu-RGD-BBN were observed in PC-3 tumor model. (18)F-FB-PEG(3)-Glu-RGD-BBN with high tumor contrast and favorable pharmacokinetics is a promising PET tracer for dual integrin and GRPR positive tumor imaging. This heterodimer strategy may also be an applicable method to develop other molecules with improved in vitro and in vivo characterizations for tumor diagnosis and therapy.

  11. [18F]CFT [(18F)WIN 35,428], a radioligand to study the dopamine transporter with PET: characterization in human subjects.

    PubMed

    Laakso, A; Bergman, J; Haaparanta, M; Vilkman, H; Solin, O; Hietala, J

    1998-03-01

    We have characterized the usage of [18F]CFT (also known as [18F]WIN 35,428) as a radioligand for in vivo studies of human dopamine transporter by PET. CFT was labeled with 18F to a high specific activity, and dynamic PET scans were conducted in healthy volunteers at various time points up to 5 h from [18F]CFT injection. The regional distribution of [18F]CFT uptake correlated well with the known distribution of dopaminergic nerve terminals in the human brain and also with that of other dopamine transporter radioligands. Striatal binding peaked at 225 min after injection and declined thereafter, demonstrating the reversible nature of the binding to the dopamine transporter. Therefore, due to the relatively long half-life of 18F (109.8 min), PET scans with [18F]CFT could easily be conducted during the binding equilibrium, allowing estimation of Bmax/Kd values (i.e., binding potential). Binding potentials for putamen and caudate measured at equilibrium were 4.79+/-0.11 and 4.50+/-0.23, respectively. We were able to also visualize midbrain dopaminergic neurons (substantia nigra) with [18F]CFT in some subjects. In conclusion, the labeling of CFT with 18F allows PET scans to be conducted at binding equilibrium, and therefore a high signal-to-noise ratio and reliable quantification of binding potential can be achieved. With a high resolution 3D PET scanner, the quantification of extrastriatal dopamine transporters should become possible.

  12. Biodistribution and catabolism of 18F-labelled isopeptide N(epsilon)-(gamma-glutamyl)-L-lysine.

    PubMed

    Hultsch, C; Bergmann, R; Pawelke, B; Pietzsch, J; Wuest, F; Johannsen, B; Henle, T

    2005-12-01

    Isopeptide bonds between the epsilon-amino group of lysine and the gamma-carboxamide group of glutamine are formed during strong heating of pure proteins or, more important, by enzymatic reaction mediated by transglutaminases. Despite the wide use of a microbial transglutaminase in food biotechnology, up to now little is known about the metabolic fate of the isopeptide N(epsilon)-(gamma-glutamyl)-L-lysine. In the present study, N-succinimidyl-4-[(18)F]fluorobenzoate was used to modify N(epsilon)-(gamma-glutamyl)-L-lysine at each of its two alpha-amino groups, resulting in the 4-[(18)F]fluorobenzoylated derivatives, for which biodistribution, catabolism, and elimination were investigated in male Wistar rats. A significant different biochemical behavior of the two labelled isopeptides was observed in terms of in vitro stability, in vivo metabolism as well as biodistribution. The results suggest that the metabolic fate of isopeptides is likely to be dependent on how they are reabsorbed - free or peptide bound.

  13. [18F]FDG labeling of neural stem cells for in vivo cell tracking with positron emission tomography: inhibition of tracer release by phloretin.

    PubMed

    Stojanov, Katica; de Vries, Erik F J; Hoekstra, Dick; van Waarde, Aren; Dierckx, Rudi A J O; Zuhorn, Inge S

    2012-02-01

    The introduction of neural stem cells into the brain has promising therapeutic potential for the treatment of neurodegenerative diseases. To monitor the cellular replacement therapy, that is, to determine stem cell migration, survival, and differentiation, in vivo tracking methods are needed. Ideally, these tracking methods are noninvasive. Noninvasive tracking methods that have been successfully used for the visualization of blood-derived progenitor cells include magnetic resonance imaging and radionuclide imaging using single-photon emission computed tomography (SPECT) and positron emission tomography (PET). The SPECT tracer In-111-oxine is suitable for stem cell labeling, but for studies in small animals, the higher sensitivity and facile quantification that can be obtained with PET are preferred. Here the potential of 2'-[18F]fluoro-2'-deoxy-D-glucose ([18F]-FDG), a PET tracer, for tracking of neural stem cell (NSCs) trafficking toward an inflammation site was investigated. [18F]-FDG turns out to be a poor radiopharmaceutical to label NSCs owing to the low labeling efficiency and substantial release of radioactivity from these cells. Efflux of [18F]-FDG from NSCs can be effectively reduced by phloretin in vitro, but inhibition of tracer release is insufficient in vivo for accurate monitoring of stem cell trafficking.

  14. Synthesis of 2'-deoxy-2'-[.sup.18F]fluoro-5-methyl-1-B-D-arabinofuranosyluracil (.sup.18F-FMAU)

    DOEpatents

    Li, Zibo; Cai, Hancheng; Conti, Peter S

    2014-12-16

    The present invention relates to methods of synthesizing .sup.18F-FMAU. In particular, .sup.18F-FMAU is synthesized using one-pot reaction conditions in the presence of Friedel-Crafts catalysts. The one-pot reaction conditions are incorporated into a fully automated cGMP-compliant radiosynthesis module, which results in a reduction in synthesis time and simplifies reaction conditions. The one-pot reaction conditions are also suitable for the production of 5-substituted thymidine or cytidine analogs. The products from the one-pot reaction (e.g. the labeled thymidine or cytidine analogs) can be used as probes for imaging tumor proliferative activity. More specifically, these [.sup.18F]-labeled thymidine or cytidine analogs can be used as a PET tracer for certain medical conditions, including, but not limited to, cancer disease, autoimmunity inflammation, and bone marrow transplant.

  15. New Dioxaborolane Chemistry Enables [(18)F]-Positron-Emitting, Fluorescent [(18)F]-Multimodality Biomolecule Generation from the Solid Phase.

    PubMed

    Rodriguez, Erik A; Wang, Ye; Crisp, Jessica L; Vera, David R; Tsien, Roger Y; Ting, Richard

    2016-05-18

    New protecting group chemistry is used to greatly simplify imaging probe production. Temperature and organic solvent-sensitive biomolecules are covalently attached to a biotin-bearing dioxaborolane, which facilitates antibody immobilization on a streptavidin-agarose solid-phase support. Treatment with aqueous fluoride triggers fluoride-labeled antibody release from the solid phase, separated from unlabeled antibody, and creates [(18)F]-trifluoroborate-antibody for positron emission tomography and near-infrared fluorescent (PET/NIRF) multimodality imaging. This dioxaborolane-fluoride reaction is bioorthogonal, does not inhibit antigen binding, and increases [(18)F]-specific activity relative to solution-based radiosyntheses. Two applications are investigated: an anti-epithelial cell adhesion molecule (EpCAM) monoclonal antibody (mAb) that labels prostate tumors and Cetuximab, an anti-epidermal growth factor receptor (EGFR) mAb (FDA approved) that labels lung adenocarcinoma tumors. Colocalized, tumor-specific NIRF and PET imaging confirm utility of the new technology. The described chemistry should allow labeling of many commercial systems, diabodies, nanoparticles, and small molecules for dual modality imaging of many diseases.

  16. A Transmetalation Reaction Enables the Synthesis of [ 18F]5-Fluorouracil from [ 18F]Fluoride for Human PET Imaging

    DOE PAGES

    Hoover, Andrew J.; Lazari, Mark; Ren, Hong; ...

    2016-02-14

    Translation of new 18F-fluorination reactions to produce radiotracers for human positron emission tomography (PET) imaging is rare because the chemistry must have useful scope and the process for 18F-labeled tracer production must be robust and simple to execute. The application of transition metal mediators has enabled impactful 18F-fluorination methods, but to date none of these reactions have been applied to produce a human-injectable PET tracer. In this article we present chemistry and process innovations that culminate in the first production from [ 18F]fluoride of human doses of [ 18F]5-fluorouracil, a PET tracer for cancer imaging in humans. Here, the firstmore » preparation of nickel σ-aryl complexes by transmetalation from arylboronic acids or esters was developed and enabled the synthesis of the [ 18F]5-fluorouracil precursor. Routine production of >10 mCi doses of [ 18F]5-fluorouracil was accomplished with a new instrument for azeotrope-free [ 18F]fluoride concentration in a process that leverages the tolerance of water in nickel-mediated 18F-fluorination.« less

  17. A Transmetalation Reaction Enables the Synthesis of [18F]5-Fluorouracil from [18F]Fluoride for Human PET Imaging

    PubMed Central

    2016-01-01

    Translation of new 18F-fluorination reactions to produce radiotracers for human positron emission tomography (PET) imaging is rare because the chemistry must have useful scope and the process for 18F-labeled tracer production must be robust and simple to execute. The application of transition metal mediators has enabled impactful 18F-fluorination methods, but to date none of these reactions have been applied to produce a human-injectable PET tracer. In this article we present chemistry and process innovations that culminate in the first production from [18F]fluoride of human doses of [18F]5-fluorouracil, a PET tracer for cancer imaging in humans. The first preparation of nickel σ-aryl complexes by transmetalation from arylboronic acids or esters was developed and enabled the synthesis of the [18F]5-fluorouracil precursor. Routine production of >10 mCi doses of [18F]5-fluorouracil was accomplished with a new instrument for azeotrope-free [18F]fluoride concentration in a process that leverages the tolerance of water in nickel-mediated 18F-fluorination. PMID:27087736

  18. A Transmetalation Reaction Enables the Synthesis of [18F]5-Fluorouracil from [18F]Fluoride for Human PET Imaging.

    PubMed

    Hoover, Andrew J; Lazari, Mark; Ren, Hong; Narayanam, Maruthi Kumar; Murphy, Jennifer M; van Dam, R Michael; Hooker, Jacob M; Ritter, Tobias

    2016-04-11

    Translation of new 18 F-fluorination reactions to produce radiotracers for human positron emission tomography (PET) imaging is rare because the chemistry must have useful scope and the process for 18 F-labeled tracer production must be robust and simple to execute. The application of transition metal mediators has enabled impactful 18 F-fluorination methods, but to date none of these reactions have been applied to produce a human-injectable PET tracer. In this article we present chemistry and process innovations that culminate in the first production from [ 18 F]fluoride of human doses of [ 18 F]5-fluorouracil, a PET tracer for cancer imaging in humans. The first preparation of nickel σ-aryl complexes by transmetalation from arylboronic acids or esters was developed and enabled the synthesis of the [ 18 F]5-fluorouracil precursor. Routine production of >10 mCi doses of [ 18 F]5-fluorouracil was accomplished with a new instrument for azeotrope-free [ 18 F]fluoride concentration in a process that leverages the tolerance of water in nickel-mediated 18 F-fluorination.

  19. A Transmetalation Reaction Enables the Synthesis of [ 18F]5-Fluorouracil from [ 18F]Fluoride for Human PET Imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoover, Andrew J.; Lazari, Mark; Ren, Hong

    Translation of new 18F-fluorination reactions to produce radiotracers for human positron emission tomography (PET) imaging is rare because the chemistry must have useful scope and the process for 18F-labeled tracer production must be robust and simple to execute. The application of transition metal mediators has enabled impactful 18F-fluorination methods, but to date none of these reactions have been applied to produce a human-injectable PET tracer. In this article we present chemistry and process innovations that culminate in the first production from [ 18F]fluoride of human doses of [ 18F]5-fluorouracil, a PET tracer for cancer imaging in humans. Here, the firstmore » preparation of nickel σ-aryl complexes by transmetalation from arylboronic acids or esters was developed and enabled the synthesis of the [ 18F]5-fluorouracil precursor. Routine production of >10 mCi doses of [ 18F]5-fluorouracil was accomplished with a new instrument for azeotrope-free [ 18F]fluoride concentration in a process that leverages the tolerance of water in nickel-mediated 18F-fluorination.« less

  20. Evaluation of Chemotherapy Response in VX2 Rabbit Lung Cancer with 18F-Labeled C2A Domain of Synaptotagmin I

    PubMed Central

    Wang, Feng; Fang, Wei; Zhang, Ming-Rong; Zhao, Ming; Liu, Biao; Wang, Zizheng; Hua, Zichun; Yang, Min; Kumata, Katsushi; Hatori, Akiko; Yamasaki, Tomoteru; Yanamoto, Kazuhiko; Suzuki, Kazutoshi

    2013-01-01

    The C2A domain of synaptotagmin I can target apoptotic cells by binding to exposed anionic phospholipids. The goal of this study was to synthesize and develop 18F-labeled C2A-gluta-thione-S-transferase (GST) as a molecular imaging probe for the detection of apoptosis and to assess the response of paclitaxel chemotherapy in VX2 rabbit lung cancer. Methods 18F-C2A-GST was prepared by labeling C2A-GST with N-succinimidyl 4-18F-fluorobenzoate (18F-SFB). 18F-C2A-GST was confirmed by high-performance liquid chromatography and sodium dodecyl sulfate polyacrylamide gel electrophoresis. The binding of 18F-C2A-GST toward apoptosis was validated in vitro using camptothecin-induced Jurkat cells. Biodistribution of 18F-C2A-GST was determined in mice by a dissection method and small-animal PET. Single-dose paclitaxel was used to induce apoptosis in rabbits bearing VX2 tumors (n = 6), and 2 VX2 rabbits without treatment served as control. 18F-C2A-GST PET was performed before and at 72 h after therapy, and 18F-FDG PET/CT was also performed before treatment. To confirm the presence of apoptosis, tumor tissue was analyzed and activated caspase-3 was measured. Results 18F-C2A-GST was obtained with more than 95% radiochemical purity and was stable for 4 h after formulation. 18F-C2A-GST bound apoptotic cells specifically. Biodistribution in mice showed that 18F-C2A-GST mainly excreted from the kidneys and rapidly cleared from blood and nonspecific organs. High focal uptake of 18F-C2A-GST in the tumor area was determined after therapy, whereas no significant uptake before therapy was found in the tumor with 18F-FDG–avid foci. The maximum standardized uptake value after therapy was 0.47 ± 0.28, significantly higher than that in the control (0.009 ± 0.001; P < 0.001). The apoptotic index was 79.81% ± 8.73% in the therapy group, significantly higher than that in the control (5.03% ± 0.81%; P < 0.001). Activated caspase-3 after paclitaxel treatment increased to 69.55% ± 16.27% and

  1. Targeting personalized medicine in a non-Hodgkin lymphoma patient with 18F-FDG and 18F-choline PET/CT.

    PubMed

    Ribeiro, Thalles H; S, Raul; Castro, Ana Carolina G; Paulino, Eduardo; Mamede, Marcelo

    2017-02-01

    Early diagnosis and staging of non-Hodgkin lymphoma (NHL) is essential for therapeutic strategy decision. Positron emission tomography/computed tomography (PET/CT) with fluordeoxyglucose (FDG), a glucose analogue, labeled with fluor-18 (18F-FDG) has been used to evaluate staging, therapy response and prognosis in NHL patients. However, in some cases, 18F-FDG has shown false-positive uptake due to inflammatory reaction after chemo and/or radiation therapy. In this case report, we present a NHL patient evaluated with 18F-FDG and 18F-choline PET/CT scan imaging pre- and post-therapy. 18F-FDG and 18F-choline PET/CT were performed for the purpose of tumor staging and have shown intense uptake in infiltrative tissue as well as in the lymph node, but with some mismatching in the tumor. Post-treatment 18F-FDG and 18F-choline PET/ CT scans revealed no signs of radiotracer uptake, suggesting complete remission of the tumor. 18F-choline may be a complimentary tool for staging and assessment of therapeutic response in non-Hodgkin lymphoma, while non-18F-FDG tracer can be used for targeted therapy and patient management.

  2. Synthesis of fluorine-18 labeled rhodamine B: A potential PET myocardial perfusion imaging agent

    PubMed Central

    Heinrich, Tobias K.; Gottumukkala, Vijay; Snay, Erin; Dunning, Patricia; Fahey, Frederic H; Treves, S. Ted; Packard, Alan B.

    2009-01-01

    There is considerable interest in developing an 18F-labeled PET myocardial perfusion agent. Rhodamine dyes share several properties with 99mTc-MIBI, the most commonly used single-photon myocardial perfusion agent, suggesting that an 18F-labeled rhodamine dye might prove useful for this application. In addition to being lipophilic cations, like 99mTc-MIBI, rhodamine dyes are known to accumulate in the myocardium and are substrates for Pgp, the protein implicated in MDR1 multidrug resistance. As the first step in determining whether 18F-labeled rhodamines might be useful as myocardial perfusion agents for PET, our objective was to develop synthetic methods for preparing the 18F-labeled compounds so that they could be evaluated in vivo. Rhodamine B was chosen as the prototype compound for development of the synthesis because the ethyl substituents on the amine moieties of rhodamine B protect them from side reactions, thus eliminating the need to include (and subsequently remove) protecting groups. The 2′-[18F]fluoroethyl ester of rhodamine B was synthesized by heating rhodamine B lactone with [18F]fluoroethyltosylate in acetonitrile at 165°C for 30 min.using [18F]fluoroethyl tosylate, which was prepared by the reaction of ethyleneglycol ditosylate with Kryptofix 2.2.2, K2CO3, and [18F]NaF in acetonitrile for 10 min. at 90°C. The product was purified by semi-preparative HPLC to produce the 2′-[18F]-fluoroethylester in >97% radiochemical purity with a specific activity of 1.3 GBq/μmol, an isolated decay corrected yield of 35%, and a total synthesis time of 90 min. PMID:19783150

  3. Preclinical comparison of Al18F- and 68Ga-labeled gastrin-releasing peptide receptor antagonists for PET imaging of prostate cancer.

    PubMed

    Chatalic, Kristell L S; Franssen, Gerben M; van Weerden, Wytske M; McBride, William J; Laverman, Peter; de Blois, Erik; Hajjaj, Bouchra; Brunel, Luc; Goldenberg, David M; Fehrentz, Jean-Alain; Martinez, Jean; Boerman, Otto C; de Jong, Marion

    2014-12-01

    Gastrin-releasing peptide receptor (GRPR) is overexpressed in human prostate cancer and is being used as a target for molecular imaging. In this study, we report on the direct comparison of 3 novel GRPR-targeted radiolabeled tracers: Al(18)F-JMV5132, (68)Ga-JMV5132, and (68)Ga-JMV4168 (JMV5132 is NODA-MPAA-βAla-βAla-[H-D-Phe-Gln-Trp-Ala-Val-Gly-His-Sta-Leu-NH2], JMV4168 is DOTA-βAla-βAla-[H-D-Phe-Gln-Trp-Ala-Val-Gly-His-Sta-Leu-NH2], and NODA-MPAA is 2-[4-(carboxymethyl)-7-{[4-(carboxymethyl)phenyl]methyl}-1,4,7-triazacyclononan-1-yl]acetic acid). The GRPR antagonist JMV594 (H-D-Phe-Gln-Trp-Ala-Val-Gly-His-Sta-Leu-NH2) was conjugated to NODA-MPAA for labeling with Al(18)F. JMV5132 was radiolabeled with (68)Ga and (18)F, and JMV4168 was labeled with (68)Ga for comparison. The inhibitory concentration of 50% values for binding GRPR of JMV4168, JMV5132, (nat)Ga-JMV4168, and (nat)Ga-JMV5132 were determined in a competition-binding assay using GRPR-overexpressing PC-3 tumors. The tumor-targeting characteristics of the compounds were assessed in mice bearing subcutaneous PC-3 xenografts. Small-animal PET/CT images were acquired, and tracer biodistribution was determined by ex vivo measurements. JMV5132 was labeled with (18)F in a novel 1-pot, 1-step procedure within 20 min, without need for further purification and resulting in a specific activity of 35 MBq/nmol. Inhibitory concentration of 50% values (in nM) for GRPR binding of JMV5132, JMV4168, (nat)Ga-JMV5132, (nat)Ga-JMV4168, and Al(nat)F-JMV5132 were 6.8 (95% confidence intervals [CIs], 4.6-10.0), 13.2 (95% CIs, 5.9-29.3), 3.0 (95% CIs, 1.5-6.0), 3.2 (95% CIs, 1.8-5.9), and 10.0 (95% CIs, 6.3-16.0), respectively. In mice with subcutaneous PC-3 xenografts, all tracers cleared rapidly from the blood, exclusively via the kidneys for (68)Ga-JMV4168 and partially hepatobiliary for (68)Ga-JMV5132 and Al(18)F-JMV5132. Two hours after injection, the uptake of (68)Ga-JMV4168, (68)Ga-JMV5132, and Al(18)F-JMV5132 in PC-3

  4. Quantitative PET Imaging of Tissue Factor Expression Using 18F-Labeled Active Site-Inhibited Factor VII.

    PubMed

    Nielsen, Carsten H; Erlandsson, Maria; Jeppesen, Troels E; Jensen, Mette M; Kristensen, Lotte K; Madsen, Jacob; Petersen, Lars C; Kjaer, Andreas

    2016-01-01

    Tissue factor (TF) is upregulated in many solid tumors, and its expression is linked to tumor angiogenesis, invasion, metastasis, and prognosis. A noninvasive assessment of tumor TF expression status is therefore of obvious clinical relevance. Factor VII is the natural ligand to TF. Here we report the development of a new PET tracer for specific imaging of TF using an (18)F-labeled derivative of factor VII. Active site-inhibited factor VIIa (FVIIai) was obtained by inactivation with phenylalanine-phenylalanine-arginine-chloromethyl ketone. FVIIai was radiolabeled with N-succinimidyl 4-(18)F-fluorobenzoate and purified. The corresponding product, (18)F-FVIIai, was injected into nude mice with subcutaneous human pancreatic xenograft tumors (BxPC-3) and investigated using small-animal PET/CT imaging 1, 2, and 4 h after injection. Ex vivo biodistribution was performed after the last imaging session, and tumor tissue was preserved for molecular analysis. A blocking experiment was performed in a second set of mice. The expression pattern of TF in the tumors was visualized by immunohistochemistry and the amount of TF in tumor homogenates was measured by enzyme-linked immunosorbent assay and correlated with the uptake of (18)F-FVIIai in the tumors measured in vivo by PET imaging. The PET images showed high uptake of (18)F-FVIIai in the tumor regions, with a mean uptake of 2.5 ± 0.3 percentage injected dose per gram (%ID/g) (mean ± SEM) 4 h after injection of 7.3-9.3 MBq of (18)F-FVIIai and with an average maximum uptake in the tumors of 7.1 ± 0.7 %ID/g at 4 h. In comparison, the muscle uptake was 0.2 ± 0.01 %ID/g at 4 h. At 4 h, the tumors had the highest uptake of any organ. Blocking with FVIIai significantly reduced the uptake of (18)F-FVIIai from 2.9 ± 0.1 to 1.4 ± 0.1 %ID/g (P < 0.001). The uptake of (18)F-FVIIai measured in vivo by PET imaging correlated (r = 0.72, P < 0.02) with TF protein level measured ex vivo. (18)F-FVIIai is a promising PET tracer for

  5. New Dioxaborolane Chemistry Enables [18F]-Positron-Emitting, Fluorescent [18F]-Multimodality Biomolecule Generation from the Solid Phase

    PubMed Central

    Crisp, Jessica L.; Vera, David R.; Tsien, Roger Y.; Ting, Richard

    2016-01-01

    New protecting group chemistry is used to greatly simplify imaging probe production. Temperature and organic solvent-sensitive biomolecules are covalently attached to a biotin-bearing dioxaborolane, which facilitates antibody immobilization on a streptavidin-agarose solid-phase support. Treatment with aqueous fluoride triggers fluoride-labeled antibody release from the solid phase, separated from unlabeled antibody, and creates [18F]-trifluoroborate-antibody for positron emission tomography and near-infrared fluorescent (PET/NIRF) multimodality imaging. This dioxaborolane-fluoride reaction is bioorthogonal, does not inhibit antigen binding, and increases [18F]-specific activity relative to solution-based radiosyntheses. Two applications are investigated: an anti-epithelial cell adhesion molecule (EpCAM) monoclonal antibody (mAb) that labels prostate tumors and Cetuximab, an anti-epidermal growth factor receptor (EGFR) mAb (FDA approved) that labels lung adenocarcinoma tumors. Colocalized, tumor-specific NIRF and PET imaging confirm utility of the new technology. The described chemistry should allow labeling of many commercial systems, diabodies, nanoparticles, and small molecules for dual modality imaging of many diseases. PMID:27064381

  6. Non-invasive glucagon-like peptide-1 receptor imaging in pancreas with {sup 18}F-Al labeled Cys{sup 39}-exendin-4

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mi, Baoming; Department of Nuclear Medicine, Affiliated Hospital of Jiangnan University; Xu, Yuping

    Purpose: Glucagon-like peptide-1 receptor (GLP-1R) is abundantly expressed on beta cells and may be an ideal target for the pancreas imaging. Monitoring the GLP-1R of pancreas could be benefit for understanding the pathophysiology of diabetes. In the present study, {sup 18}F-Al labeled exendin-4 analog, {sup 18}F-Al-NOTA-MAL-Cys{sup 39}-exendin-4, was evaluated for PET imaging GLP-1R in the pancreas. Methods: The targeting of {sup 18}F-Al labeled exendin-4 analog was examined in healthy and streptozotocin induced diabetic rats. Rats were injected with {sup 18}F-Al-NOTA-MAL-Cys{sup 39}-exendin-4 and microPET imaging was performed at 1 h postinjection, followed by ex vivo biodistribution. GLP-1R expression in pancreas was determined throughmore » post mortern examinations. Results: The pancreas of healthy rats was readily visualized after administration of {sup 18}F-Al-NOTA-MAL-Cys{sup 39}-exendin-4, whereas the pancreas of diabetic rats, as well as those from rats co-injected with excess of unlabeled peptides, was barely visible by microPET. At 60 min postinjection, the pancreatic uptakes were 1.02 ± 0.15%ID/g and 0.23 ± 0.05%ID/g in healthy and diabetic rats respectively. Under block, the pancreatic uptakes of non-diabetic rats reduced to 0.21 ± 0.07%ID/g at the same time point. Biodistribution data and IHC staining confirmed the findings of the microPET imaging. Conclusion: The favorable preclinical data indicated that {sup 18}F-Al-NOTA-MAL-Cys{sup 39}-exendin-4may be suitable for non-invasive monitoring functional pancreatic beta cells.« less

  7. In Vitro and In Vivo Evaluation of a 18F-Labeled High Affinity NOTA Conjugated Bombesin Antagonist as a PET Ligand for GRPR-Targeted Tumor Imaging

    PubMed Central

    Velikyan, Irina; Lindeberg, Gunnar; Sörensen, Jens; Larhed, Mats; Antoni, Gunnar; Sandström, Mattias; Tolmachev, Vladimir; Orlova, Anna

    2013-01-01

    Expression of the gastrin-releasing peptide receptor (GRPR) in prostate cancer suggests that this receptor can be used as a potential molecular target to visualize and treat these tumors. We have previously investigated an antagonist analog of bombesin (D-Phe-Gln-Trp-Ala-Val-Gly-His-Sta-Leu-NH2, RM26) conjugated to 1,4,7-triazacyclononane-N,N',N''-triacetic acid (NOTA) via a diethylene glycol (PEG2) spacer (NOTA-P2-RM26) labeled with 68Ga and 111In. We found that this conjugate has favorable properties for in vivo imaging of GRPR-expression. The focus of this study was to develop a 18F-labelled PET agent to visualize GRPR. NOTA-P2-RM26 was labeled with 18F using aluminum-fluoride chelation. Stability, in vitro binding specificity and cellular processing tests were performed. The inhibition efficiency (IC50) of the [natF]AlF-NOTA-P2-RM26 was compared to that of the natGa-loaded peptide using 125I-Tyr4-BBN as the displacement radioligand. The pharmacokinetics and in vivo binding specificity of the compound were studied. NOTA-P2-RM26 was labeled with 18F within 1 h (60-65% decay corrected radiochemical yield, 55 GBq/µmol). The radiopeptide was stable in murine serum and showed high specific binding to PC-3 cells. [natF]AlF-NOTA-P2-RM26 showed a low nanomolar inhibition efficiency (IC50=4.4±0.8 nM). The internalization rate of the tracer was low. Less than 14% of the cell-bound radioactivity was internalized after 4 h. The biodistribution of [18F]AlF-NOTA-P2-RM26 demonstrated rapid blood clearance, low liver uptake and low kidney retention. The tumor uptake at 3 h p.i. was 5.5±0.7 %ID/g, and the tumor-to-blood, -muscle and -bone ratios were 87±42, 159±47, 38±16, respectively. The uptake in tumors, pancreas and other GRPR-expressing organs was significantly reduced when excess amount of non-labeled peptide was co-injected. The low uptake in bone suggests a high in vivo stability of the Al-F bond. High contrast PET image was obtained 3 h p.i. The initial biological

  8. Reusable electrochemical cell for rapid separation of [18F]fluoride from [18O]water for flow-through synthesis of 18F-labeled tracers

    PubMed Central

    Sadeghi, Saman; Liang, Vincent; Cheung, Shilin; Woo, Suh; Wu, Curtis; Ly, Jimmy; Deng, Yuliang; Eddings, Mark; van Dam, R. Michael

    2015-01-01

    A brass-platinum electrochemical micro flow cell was developed to extract [18F]fluoride from an aqueous solution and release it into an organic based solution, suitable for subsequent radio-synthesis, in a fast and reliable manner. This cell does not suffer electrode erosion and is thus reusable while operating faster by enabling increased voltages. By optimizing temperature, trapping and release potentials, flow rates, and electrode materials, an overall [18F]fluoride trapping and release efficiency of 84±5% (n=7) was achieved. X-ray photoelectron spectroscopy (XPS) was used to analyze electrode surfaces of various metal-metal systems and the findings were correlated with the performance of the electrochemical cell. To demonstrate the reactivity of the released [18F]fluoride, the cell was coupled to a flow-through reactor and automated synthesis of [18F]FDG with a repeatable decay-corrected yield of 56±4% (n=4) was completed in <15 min. A multi-human dose of 5.92 GBq [18F]FDG was also demonstrated. PMID:23474380

  9. Fluorine-18 Labeling of the HER2-Targeting Single-Domain Antibody 2Rs15d Using a Residualizing Label and Preclinical Evaluation.

    PubMed

    Zhou, Zhengyuan; Vaidyanathan, Ganesan; McDougald, Darryl; Kang, Choong Mo; Balyasnikova, Irina; Devoogdt, Nick; Ta, Angeline N; McNaughton, Brian R; Zalutsky, Michael R

    2017-12-01

    Our previous studies with F-18-labeled anti-HER2 single-domain antibodies (sdAbs) utilized 5F7, which binds to the same epitope on HER2 as trastuzumab, complicating its use for positron emission tomography (PET) imaging of patients undergoing trastuzumab therapy. On the other hand, sdAb 2Rs15d binds to a different epitope on HER2 and thus might be a preferable vector for imaging in these patients. The aim of this study was to evaluate the tumor targeting of F-18 -labeled 2Rs15d in HER2-expressing breast carcinoma cells and xenografts. sdAb 2Rs15d was labeled with the residualizing labels N-succinimidyl 3-((4-(4-[ 18 F]fluorobutyl)-1H-1,2,3-triazol-1-yl)methyl)-5-(guanidinomethyl)benzoate ([ 18 F]RL-I) and N-succinimidyl 4-guanidinomethyl-3-[ 125 I]iodobenzoate ([ 125 I]SGMIB), and the purity and HER2-specific binding affinity and immunoreactivity were assessed after labeling. The biodistribution of I-125- and F-18-labeled 2Rs15d was determined in SCID mice bearing subcutaneous BT474M1 xenografts. MicroPET/x-ray computed tomograph (CT) imaging of [ 18 F]RL-I-2Rs15d was performed in this model and compared to that of nonspecific sdAb [ 18 F]RL-I-R3B23. MicroPET/CT imaging was also done in an intracranial HER2-positive breast cancer brain metastasis model after administration of 2Rs15d-, 5F7-, and R3B23-[ 18 F]RL-I conjugates. [ 18 F]RL-I was conjugated to 2Rs15d in 40.8 ± 9.1 % yield and with a radiochemical purity of 97-100 %. Its immunoreactive fraction (IRF) and affinity for HER2-specific binding were 79.2 ± 5.4 % and 7.1 ± 0.4 nM, respectively. [ 125 I]SGMIB was conjugated to 2Rs15d in 58.4 ± 8.2 % yield and with a radiochemical purity of 95-99 %; its IRF and affinity for HER2-specific binding were 79.0 ± 12.9 % and 4.5 ± 0.8 nM, respectively. Internalized radioactivity in BT474M1 cells in vitro for [ 18 F]RL-I-2Rs15d was 43.7 ± 3.6, 36.5 ± 2.6, and 21.7 ± 1.2 % of initially bound radioactivity at 1, 2, and 4 h, respectively

  10. The efficiency of 18F labelling of a prostate specific membrane antigen ligand via strain-promoted azide-alkyne reaction: reaction speed versus hydrophilicity.

    PubMed

    Wang, Mengzhe; McNitt, Christopher D; Wang, Hui; Ma, Xiaofen; Scarry, Sarah M; Wu, Zhanhong; Popik, Vladimir V; Li, Zibo

    2018-06-27

    Here we report the 18F labeling of a prostate specific membrane antigen (PSMA) ligand via a strain promoted oxa-dibenzocyclooctyne (ODIBO)- or bicyclo[6.1.0]nonyne (BCN)-azide reaction. Although ODIBO reacts with azide 20 fold faster than BCN, in vivo PET imaging suggests that 18F-BCN-azide-PSMA demonstrated much higher tumor uptake and a much higher tumor to background contrast.

  11. Synthesis of Fluorine-Containing Phosphodiesterase 10A (PDE10A) Inhibitors and the In Vivo Evaluation of F-18 Labeled PDE10A PET Tracers in Rodent and Nonhuman Primate

    PubMed Central

    Li, Junfeng; Zhang, Xiang; Jin, Hongjun; Fan, Jinda; Flores, Hubert; Perlmutter, Joel S.; Tu, Zhude

    2015-01-01

    A series of fluorine-containing PDE10A inhibitors were designed and synthesized to improve the metabolic stability of [11C]MP-10. Twenty of the 22 new analogues had high potency and selectivity for PDE10A: 18a–j, 19d–j, 20a–b, and 21b had IC50 values <5 nM for PDE10A. Seven F-18 labeled compounds [18F]18a–e, [18F]18g, and [18F]20a were radiosynthesized by 18F-introduction onto the quinoline rather than the pyrazole moiety of the MP-10 pharmacophore and performed in vivo evaluation. Biodistribution studies in rats showed ~2-fold higher activity in the PDE10A-enriched striatum than nontarget brain regions; this ratio increased from 5 to 30 min postinjection, particularly for [18F]18a–d and [18F]20a. Micro-PET studies of [18F]18d and [18F]20a in nonhuman primates provided clear visualization of striatum with suitable equilibrium kinetics and favorable metabolic stability. These results suggest this strategy may identify a 18F-labeled PET tracer for quantifying the levels of PDE10A in patients with CNS disorders including Huntington’s disease and schizophrenia. PMID:26430878

  12. Fluorine-18 labeled tracers for PET studies in the neurosciences

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ding, Yu-Shin; Fowler, J.S.

    This chapter focuses on fluorine-18, the positron emitter with the longest half-life, the lowest positron energy and probably, the most challenging chemistry. The incorporation of F-18 into organic compounds presents many challenges, including: the need to synthesize and purify the compound within a 2--3 hour time frame; the limited number of labeled precursor molecules; the need to work on a microscale; and the need to produce radiotracers which are chemically and radiochemically pure, sterile and pyrogen-free, and suitable for intravenous injection. The PET method and F-18 labeling of organic molecules are described followed by highlights of the applications of F-18more » labeled compounds in the neurosciences and neuropharmacology. It is important to emphasize the essential and pivotal role that organic synthesis has played in the progression of the PET field over the past twenty years from one in which only a handful of institutions possessed the instrumentation and staff to carry out research to the present-day situation where there are more than 200 PET centers worldwide. During this period PET has become an important scientific tool in the neurosciences, cardiology and oncology. It is important to point out that PET is by no means a mature field. The fact that a hundreds of different F-18 labeled compounds have been developed but only a few possess the necessary selectivity and sensitivity in vivo to track a specific biochemical process illustrates this and underscores a major difficulty in radiotracer development, namely the selection of priority structures for synthesis and the complexities of the interactions between chemical compounds and living systems. New developments in rapid organic synthesis are needed in order to investigate new molecular targets and to improve the quantitative nature of PET experiments.« less

  13. A broadly applicable [18F]trifluoromethylation of aryl and heteroaryl iodides for PET imaging

    NASA Astrophysics Data System (ADS)

    Huiban, Mickael; Tredwell, Matthew; Mizuta, Satoshi; Wan, Zehong; Zhang, Xiaomin; Collier, Thomas Lee; Gouverneur, Véronique; Passchier, Jan

    2013-11-01

    Molecules labelled with the unnatural isotope fluorine-18 are used for positron emission tomography. Currently, this molecular imaging technology is not exploited at its full potential because many 18F-labelled probes are inaccessible or notoriously difficult to produce. Typical challenges associated with 18F radiochemistry are the short half-life of 18F (<2 h), the use of sub-stoichiometric amounts of 18F, relative to the precursor and other reagents, as well as the limited availability of parent 18F sources of suitable reactivity ([18F]F- and [18F]F2). There is a high-priority demand for general methods allowing access to [18F]CF3-substituted molecules for application in pharmaceutical discovery programmes. We report the development of a process for the late-stage [18F]trifluoromethylation of (hetero)arenes from [18F]fluoride using commercially available reagents and (hetero)aryl iodides. This [18F]CuCF3-based protocol benefits from a large substrate scope and is characterized by its operational simplicity.

  14. General method for labeling siRNA by click chemistry with fluorine-18 for the purpose of PET imaging.

    PubMed

    Mercier, Frédéric; Paris, Jérôme; Kaisin, Geoffroy; Thonon, David; Flagothier, Jessica; Teller, Nathalie; Lemaire, Christian; Luxen, André

    2011-01-19

    The alkyne-azide Cu(I)-catalyzed Huisgen cycloaddition, a click-type reaction, was used to label a double-stranded oligonucleotide (siRNA) with fluorine-18. An alkyne solid support CPG for the preparation of monostranded oligonucleotides functionalized with alkyne has been developed. Two complementary azide labeling agents (1-(azidomethyl)-4-[(18)F]fluorobenzene) and 1-azido-4-(3-[(18)F]fluoropropoxy)benzene have been produced with 41% and 35% radiochemical yields (decay-corrected), respectively. After annealing with the complementary strand, the siRNA was directly labeled by click chemistry with [(18)F]fluoroazide to produce the [(18)F]-radiolabeled siRNA with excellent radiochemical yield and purity.

  15. Fully automated synthesis of 4-[18F]fluorobenzylamine based on borohydride/NiCl2 reduction.

    PubMed

    Way, Jenilee; Wuest, Frank

    2013-04-01

    4-[(18)F]Fluorobenzylamine ([(18)F]FBA) is an important building block for the synthesis of (18)F-labeled compounds. Synthesis of [(18)F]FBA usually involves application of strong reducing agents like LiAlH4 which is challenging to handle in automated synthesis units (ASUs). Therefore, alternative methods for the preparation of [(18)F]FBA compatible with remotely-controlled syntheses in ASUs are needed. (18)F]FBA was prepared in a remotely-controlled synthesis unit (GE TRACERlab™ FX) based on Ni(II)-mediated borohydride exchange resin (BER) reduction of 4-[(18)F]fluorobenzonitrile ([(18)F]FBN). [(18)F]FBA was used for the synthesis of novel thiol-reactive prosthetic group 4-[(18)F]fluorobenzyl)maleimide [(18)F]FBM and Hsp90 inhibitor 17-(4-[(18)F]fluorobenzylamino)-17-demethoxy-geldanamycin [(18)F] GA. [(18)F]FBA could be prepared in high radiochemical yield greater than 80% (decay-corrected) within 60min. In a typical experiment, 7.4GBq of [(18)F]FBA could be obtained in high radiochemical purity of greater than 95% starting from 10GBq of cyclotron-produced n.c.a. [(18)F]fluoride. [(18)F]FBA was used for the preparation of 4-[(18)F]fluorobenzyl)maleimide as a novel prosthetic group for labeling of thiol groups as demonstrated with tripeptide glutathione. [(18)F]FBA was also used as building block for the syntheses of small molecules as exemplified by the preparation of Hsp90 inhibitor 17-(4-[(18)F]fluorobenzylamino)-17-demethoxy-geldanamycin. The described remotely-controlled synthesis of [(18)F]FBA will significantly improve the availability of [(18)F]FBA as an important and versatile building block for the development of novel (18)F-labeled compounds containing a fluorobenzylamine moiety. Copyright © 2013 Elsevier Inc. All rights reserved.

  16. Fluorine-18 NaF PET imaging of child abuse.

    PubMed

    Drubach, Laura A; Sapp, Mark V; Laffin, Stephen; Kleinman, Paul K

    2008-07-01

    We describe the use of 18F-NaF positron emission tomography (PET) whole-body imaging for the evaluation of skeletal trauma in a case of suspected child abuse. To our knowledge, 18F NaF PET has not been used in the past for the evaluation of child abuse. In our patient, this technique detected all sites of trauma shown by initial and follow-up skeletal surveys, including bilateral metaphyseal fractures of the proximal humeri. Fluorine-18 NaF PET has potential advantage over Tc-99m-labeled methylene diphosphonate (MDP) based upon superior image contrast and spatial resolution.

  17. Comparison of 4'-[methyl-(11)C]thiothymidine ((11)C-4DST) and 3'-deoxy-3'-[(18)F]fluorothymidine ((18)F-FLT) PET/CT in human brain glioma imaging.

    PubMed

    Toyota, Yasunori; Miyake, Keisuke; Kawai, Nobuyuki; Hatakeyama, Tetsuhiro; Yamamoto, Yuka; Toyohara, Jun; Nishiyama, Yoshihiro; Tamiya, Takashi

    2015-01-01

    3'-deoxy-3'-[(18)F]fluorothymidine ((18)F-FLT) has been used to evaluate tumor malignancy and cell proliferation in human brain gliomas. However, (18)F-FLT has several limitations in clinical use. Recently, (11)C-labeled thymidine analogue, 4'-[methyl-(11)C]thiothymidine ((11)C-4DST), became available as an in vivo cell proliferation positron emission tomography (PET) tracer. The present study was conducted to evaluate the usefulness of (11)C-4DST PET in the diagnosis of human brain gliomas by comparing with the images of (18)F-FLT PET. Twenty patients with primary and recurrent brain gliomas underwent (18)F-FLT and (11)C-4DST PET scans. The uptake values in the tumors were evaluated using the maximum standardized uptake value (SUVmax), the tumor-to-normal tissue uptake (T/N) ratio, and the tumor-to-blood uptake (T/B) ratio. These values were compared among different glioma grades. Correlation between the Ki-67 labeling index and the uptake values of (11)C-4DST and (18)F-FLT in the tumor was evaluated using linear regression analysis. The relationship between the individual (18)F-FLT and (11)C-4DST uptake values in the tumors was also examined. (11)C-4DST uptake was significantly higher than that of (18)F-FLT in the normal brain. The uptake values of (11)C-4DST in the tumor were similar to those of (18)F-FLT resulting in better visualization with (18)F-FLT. No significant differences in the uptake values of (18)F-FLT and (11)C-4DST were noted among different glioma grades. Linear regression analysis showed a significant correlation between the Ki-67 labeling index and the T/N ratio of (11)C-4DST (r = 0.50, P < 0.05) and (18)F-FLT (r = 0.50, P < 0.05). Significant correlations were also found between the Ki-67 labeling index and the T/B ratio of (11)C-4DST (r = 0.52, P < 0.05) and (18)F-FLT (r = 0.55, P < 0.05). A highly significant correlation was observed between the individual T/N ratio of (11)C-4DST and (18)F-FLT in the tumor (r

  18. Simplified one-pot synthesis of [.sup.18F]SFB for radiolabeling

    DOEpatents

    Olma, Sebastian; Shen, Clifton Kwang-Fu

    2015-08-04

    A non-aqueous single pot synthesis of [.sup.18F]SFB is set forth. The [.sup.18F]SFB produced with this method is then used, for example, to label a peptide or an engineered antibody fragment (diabody) targeting human epidermal growth factor receptor 2 (HER2) as representative examples of labeled compounds for use as an injectable composition to locate abnormal tissue, specifically tumors within an animal or human using a PET scan.

  19. Simplified one-pot synthesis of [.sup.18F]SFB for radiolabeling

    DOEpatents

    Olma, Sebastian; Shen, Clifton Kwang-Fu

    2013-07-16

    A non-aqueous single pot synthesis of [.sup.18F]SFB is set forth. The [.sup.18F]SFB produced with this method is then used, for example, to label a peptide or an engineered antibody fragment (diabody) targeting human epidermal growth factor receptor 2 (HER2) as representative examples of labeled compounds for use as an injectable composition to locate abnormal tissue, specifically tumors within an animal or human using a PET scan.

  20. GMP-compliant automated synthesis of [(18)F]AV-45 (Florbetapir F 18) for imaging beta-amyloid plaques in human brain.

    PubMed

    Yao, Cheng-Hsiang; Lin, Kun-Ju; Weng, Chi-Chang; Hsiao, Ing-Tsung; Ting, Yi-Shu; Yen, Tzu-Chen; Jan, Tong-Rong; Skovronsky, Daniel; Kung, Mei-Ping; Wey, Shiaw-Pyng

    2010-12-01

    We report herein the Good Manufacturing Practice (GMP)-compliant automated synthesis of (18)F-labeled styrylpyridine, AV-45 (Florbetapir), a novel tracer for positron emission tomography (PET) imaging of beta-amyloid (Abeta) plaques in the brain of Alzheimer's disease patients. [(18)F]AV-45 was prepared in 105 min using a tosylate precursor with Sumitomo modules for radiosynthesis under GMP-compliant conditions. The overall yield was 25.4+/-7.7% with a final radiochemical purity of 95.3+/-2.2% (n=19). The specific activity of [(18)F]AV-45 reached as high as 470+/-135 TBq/mmol (n=19). The present studies show that [(18)F]AV-45 can be manufactured under GMP-compliant conditions and could be widely available for routine clinical use. Copyright 2010 Elsevier Ltd. All rights reserved.

  1. Development of [18F]afatinib as new TKI-PET tracer for EGFR positive tumors.

    PubMed

    Slobbe, Paul; Windhorst, Albert D; Stigter-van Walsum, Marijke; Schuit, Robert C; Smit, Egbert F; Niessen, Heiko G; Solca, Flavio; Stehle, Gerd; van Dongen, Guus A M S; Poot, Alex J

    2014-10-01

    Afatinib is an irreversible ErbB family blocker that was approved for the treatment of EGFR mutated non-small cell lung cancer in 2013. Positron emission tomography (PET) with fluorine-18 labeled afatinib provides a means to obtain improved understanding of afatinib tumor disposition in vivo. PET imaging with [(18)F]afatinib may also provide a method to select treatment responsive patients. The aim of this study was to label afatinib with fluorine-18 and evaluate its potential as TKI-PET tracer in tumor bearing mice. A radiochemically novel coupling, using peptide coupling reagent BOP, was explored and optimized to synthesize [(18)F]afatinib, followed by a metabolite analysis and biodistribution studies in two clinically relevant lung cancer cell lines, xenografted in nude mice. A reliable [(18)F]afatinib radiosynthesis was developed and the tracer could be produced in yields of 17.0 ± 2.5% calculated from [(18)F]F(-) and >98% purity. The identity of the product was confirmed by co-injection on HPLC with non-labeled afatinib. Metabolite analysis revealed a moderate rate of metabolism, with >80% intact tracer in plasma at 45 min p.i. Biodistribution studies revealed rapid tumor accumulation and good retention for a period of at least 2 hours, while background tissues showed rapid clearance of the tracer. We have developed a method to synthesize [(18)F]afatinib and related fluorine-18 labeled 4-anilinoquinazolines. [(18)F]Afatinib showed good stability in vivo, justifying further evaluation as a TKI-PET tracer. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. Comparison study of [18F]FAl-NOTA-PRGD2, [18F]FPPRGD2, and [68Ga]Ga-NOTA-PRGD2 for PET imaging of U87MG tumors in mice.

    PubMed

    Lang, Lixin; Li, Weihua; Guo, Ning; Ma, Ying; Zhu, Lei; Kiesewetter, Dale O; Shen, Baozhong; Niu, Gang; Chen, Xiaoyuan

    2011-12-21

    [(18)F]FPPRGD2, an F-18 labeled dimeric cyclic RGDyK peptide, has favorable properties for PET imaging of angiogenesis by targeting the α(v)β(3) integrin receptor. This radiotracer has been approved by the FDA for use in clinical trials. However, the time-consuming multiple-step synthetic procedure required for its preparation may hinder the widespread usage of this tracer. The recent development of a method using an F-18 fluoride-aluminum complex to radiolabel peptides provides a strategy for simplifying the labeling procedure. On the other hand, the easy-to-prepare [(68)Ga]-labeled NOTA-RGD derivatives have also been reported to have promising properties for imaging α(v)β(3) integrin receptors. The purpose of this study was to prepare [(18)F]FPPRGD2 [corrected] , [(18)F]FAl-NOTA-PRGD2, and [(68)Ga]Ga-NOTA-PRGD2 and to compare their pharmacokinetics and tumor imaging properties using small animal PET. All three compounds showed rapid and high tracer uptake in U87MG tumors with high target-to-background ratios. The uptake in the liver, kidneys, and muscle were similar for all three tracers, and they all showed predominant renal clearance. In conclusion, [(18)F]FAl-NOTA-PRGD2 and [(68)Ga]Ga-NOTA-PRGD2 have imaging properties and pharmacokinetics comparable to those of [(18)F]FPPRGD2. Considering their ease of preparation and good imaging qualities, [(18)F]FAl-NOTA-PRGD2 and [(68)Ga]NOTA-PRGD2 are promising alternatives to [(18)F]FPPRGD2 for PET imaging of tumor α(v)β(3) integrin expression.

  3. No-carrier-added (18F)-N-methylspiroperidol

    DOEpatents

    Shiue, Chyng-Yann; Fowler, Joanna S.; Wolf, Alfred P.

    1993-01-01

    There is disclosed a radioligand labeled with a positron emitting radionuclide suitable for dynamic study in living humans with positron emission transaxial tomography. [.sup.18 F]-N-methylspiroperidol, exhibiting extremely high affinity for the dopamine receptors, provides enhanced uptake and retention in the brain concomitant with reduced radiation burden. These characteristics all combine to provide [.sup.18 F]-N-methylspiroperidol as a radioligand superior to known radioligands for mapping dopamine receptors in normal and disease states in the living brain. Additionally, a new synthetic procedure for this material is disclosed.

  4. No-carrier-added (18F)-N-methylspiroperidol

    DOEpatents

    Shiue, Chyng-Yann; Fowler, Joanna S.; Wolf, Alfred P.

    1993-07-06

    There is disclosed a radioligand labeled with a positron emitting radionuclide suitable for dynamic study in living humans with positron emission transaxial tomography. [.sup.18 F]-N-methylspiroperidol, exhibiting extremely high affinity for the dopamine receptors, provides enhanced uptake and retention in the brain concomitant with reduced radiation burden. These characteristics all combine to provide [.sup.18 F]-N-methylspiroperidol as a radioligand superior to known radioligands for mapping dopamine receptors in normal and disease states in the living brain. Additionally, a new synthetic procedure for this material is disclosed.

  5. Radiolabelling of isopeptide N epsilon-(gamma-glutamyl)-L-lysine by conjugation with N-succinimidyl-4-[18F]fluorobenzoate.

    PubMed

    Wüst, F; Hultsch, C; Bergmann, R; Johannsen, B; Henle, T

    2003-07-01

    The isopeptide N(epsilon)-(gamma-glutamyl)-L-lysine 4 was labelled with 18F via N-succinimidyl-4-[18F]fluorobenzoate ([18F]SFB). A modified approach for the convenient synthesis of [18F]SFB was used, and [18F]SFB could be obtained in decay-corrected radiochemical yields of 44-53% (n = 20) and radiochemical purity >95% within 40 min after EOB. For labelling N(epsilon)-(gamma-glutamyl)-L-lysine with [18F]SFB the effects of isopeptide concentration, temperature, and pH were studied to determine the optimum reaction conditions. The coupling reaction was shown to be temperature and pH independent while being strongly affected by the isopeptide concentration. Using the optimized labelling conditions, in a typical experiment 1.3GBq of [18F]SFB could be converted into 447MBq (46%, decay-corrected) of [18F]fluorobenzoylated isopeptide within 45 min, including HPLC purification.

  6. (R)-N-Methyl-3-(3′-[18F]fluoropropyl)phenoxy)-3-phenylpropanamine (18F-MFP3) as a potential PET imaging agent for norepinephrine transporter

    PubMed Central

    Nguyen, Vivien L.; Pichika, Rama; Bhakta, Paayal H.; Kant, Ritu; Mukherjee, Jogeshwar

    2010-01-01

    A decline of norepinephrine transporter (NET) level is associated with several psychiatric and neurological disorders. Therefore positron emission tomography (PET) imaging agents are greatly desired to study the NET pathway. We have developed a C-fluoropropyl analog of nisoxetine: (R)-N-methyl-3-(3′-[18F]fluoropropyl)phenoxy)-3-phenylpropanamine (18F-MFP3) as a new potential PET radiotracer for NET with the advantage of the longer half-life of fluorine-18 (110 min compared with carbon-11 (20 min). Synthesis of (R)-N-methyl-3-(3′-fluoropropyl)phenoxy)-3-phenylpropanamine (MFP3) was achieved in five steps starting from (S)-N-methyl-3-ol-3-phenylpropanamine in approx. 3–5% overall yields. In vitro binding affinity of nisoxetine and MFP3 in rat brain homogenates labeled with 3H-nisoxetine gave Ki values of 8.02 nM and 23 nM, respectively. For radiosynthesis of 18F-MFP3, fluorine-18 was incorporated into a tosylate precursor, followed by the deprotection of the N-BOC-protected amine group with a 15% decay corrected yield in 2.5 h. Reverse-phase chromatographic purification provided 18F-MFP3 in specific activities of >2000 Ci/mmol. Fluorine-18 labeled 18F-MFP3 has been produced in modest radiochemical yields and in high specific activities. Evaluation of 18F-MFP3 in animal imaging studies is in progress in order to validate this new fluorine-18 radiotracer for PET imaging of NET. PMID:20495670

  7. Safety, pharmacokinetics, metabolism and radiation dosimetry of 18F-tetrafluoroborate (18F-TFB) in healthy human subjects.

    PubMed

    Jiang, Huailei; Schmit, Nicholas R; Koenen, Alex R; Bansal, Aditya; Pandey, Mukesh K; Glynn, Robert B; Kemp, Bradley J; Delaney, Kera L; Dispenzieri, Angela; Bakkum-Gamez, Jamie N; Peng, Kah-Whye; Russell, Stephen J; Gunderson, Tina M; Lowe, Val J; DeGrado, Timothy R

    2017-10-27

    18 F-Tetrafluoroborate ( 18 F-TFB) is a promising iodide analog for PET imaging of thyroid cancer and sodium/iodide symporter (NIS) reporter activity in viral therapy applications. The aim of this study was to evaluate the safety, pharmacokinetics, biodistribution, and radiation dosimetry of high-specific activity 18 F-TFB in healthy human subjects. 18 F-TFB was synthesized with specific activity of 3.2 ± 1.3 GBq/μmol (at the end of synthesis). Dynamic and whole-body static PET/CT scans over 4 h were performed after intravenous administration of 18 F-TFB (333-407 MBq) in four female and four male healthy volunteers (35 ± 11 years old). Samples of venous blood and urine were collected over the imaging period and analyzed by ion-chromatography HPLC to determine tracer stability. Vital signs and clinical laboratory safety assays were measured to evaluate safety. 18 F-TFB administration was well tolerated with no significant findings on vital signs and no clinically meaningful changes in clinical laboratory assays. Left-ventricular blood pool time-activity curves showed a multi-phasic blood clearance of 18 F-radioactivity with the two rapid clearance phases over the first 20 min, followed by a slower clearance phase. HPLC analysis showed insignificant 18 F-labeled metabolites in the blood and urine over the length of the study (4 h). High uptakes were seen in the thyroid, stomach, salivary glands, and bladder. Urinary clearance of 18 F-TFB was prominent. Metabolic stability was evidenced by low accumulation of 18 F-radioactivity in the bone. Effective doses were 0.036 mSv/MBq in males and 0.064 mSv/MBq in females (p = 0.08, not significant). This initial study in healthy human subjects showed 18 F-TFB was safe and distributed in the human body similar to other iodide analogs. These data support further translational studies with 18 F-TFB as NIS gene reporter and imaging biomarker for thyroid cancer and other disease processes that import iodide.

  8. Synthesis of a potent and selective (18)F-labeled delta-opioid receptor antagonist derived from the Dmt-Tic pharmacophore for positron emission tomography imaging.

    PubMed

    Ryu, Eun Kyoung; Wu, Zhanhong; Chen, Kai; Lazarus, Lawrence H; Marczak, Ewa D; Sasaki, Yusuke; Ambo, Akihiro; Salvadori, Severo; Ren, Chuancheng; Zhao, Heng; Balboni, Gianfranco; Chen, Xiaoyuan

    2008-03-27

    Identification and pharmacological characterization of two new selective delta-opioid receptor antagonists, derived from the Dmt-Tic pharmacophore, of potential utility in positron emission tomography (PET) imaging are described. On the basis of its high delta selectivity, H-Dmt-Tic--Lys(Z)-OH (reference compound 1) is a useful starting point for the synthesis of (18)F-labeled compounds prepared by the coupling of N-succinimidyl 4-[ (18)F]fluorobenzoate ([(18)F]SFB) with Boc-Dmt-Tic--Lys(Z)-OH under slightly basic conditions at 37 degrees C for 15 min, deprotection with TFA, and HPLC purification. The total synthesis time was 120 min, and the decay-corrected radiochemical yield of [(18)F]- 1 was about 25-30% ( n = 5) starting from [(18)F]SFB ( n = 5) with an effective specific activity about 46 GBq/micromol. In vitro autoradiography studies showed prominent uptake of [ (18)F]- 1 in the striatum and cortex with significant blocking by 1 and UFP-501 (selective delta-opioid receptor antagonist), suggesting high specific binding of [(18)F]- 1 to delta-opioid receptors. Noninvasive microPET imaging studies revealed the absence of [(18)F]- 1 in rat brain, since it fails to cross the blood-brain barrier. This study demonstrates the suitability of [ (18)F]- 1 for imaging peripheral delta-opioid receptors.

  9. Validation of a [Al18F]PSMA-11 preparation for clinical applications.

    PubMed

    Al-Momani, Ehab; Israel, Ina; Samnick, Samuel

    2017-12-01

    Imaging prostate-specific membrane antigen (PSMA) using positron emission tomography (PET) has been presented so far as the most sensitive and specific with regard to prostate cancer detection, in particular in high-risk prostate cancer patients. Currently, it mainly features Gallium-68 ( 68 Ga) labeled PSMA ligands, notably [ 68 Ga]Glu-urea-Lys(Ahx)-HBED-CC ([ 68 Ga]-PSMA-11) and [ 68 Ga]DOTAGA-FFK (Sub-KuE termed ([ 68 Ga]PSMA-I&T). However, 68 Ga has several shortcomings as radionuclide including a short half-life and non-ideal energies. This has motivated consideration of 18 F-labeled analogues for PET imaging of prostate cancer. Here, we describe a simple synthesis and validation of a fluorine-18 labeled Glu-urea-Lys(Ahx)-HBED-CC ([Al 18 F]PSMA-11) for nuclear medicine applications. An efficient method for preparation of [Al 18 F]PSMA-11 was developed and validated (according to Pharm Eur) for routinely clinical applications. [Al 18 F]PSMA-11 was reproducibly obtained in radiochemical yields of 84 ± 6% (n = 15) and > 98% radiochemical purity using an improved one-step radiofluorination in aqueous solution. The total (production/preparation) time, including purification, pharmacological formulation of the isolated product and the quality control of the injectable solution was less than 60min. The [Al 18 F]PSMA-11 was stable over 4h in 1% EtOH/saline selected as injection solution. The solution was sterile, non-pyrogenic and ready for clinical applications after sterile filtration through a 0.22µm membrane filter under sterile conditions. In addition, [Al 18 F]PSMA-11 exhibited higher uptake and retention in PMSA-expressing LNCap prostate cells as compared to its clinically established 68 Ga-labeled analogues [ 68 Ga]PSMA-11 and [ 68 Ga]PSMA-I&T as well as to [ 68 Ga]NOTA-Bn-PSMA. The simple and fast preparation of [Al 18 F]PSMA-11 combined with its favorable pharmacological properties warrant its translation to a clinical setting. The facile and high

  10. Comparison of three dimeric 18F-AlF-NOTA-RGD tracers.

    PubMed

    Guo, Jinxia; Lang, Lixin; Hu, Shuo; Guo, Ning; Zhu, Lei; Sun, Zhongchan; Ma, Ying; Kiesewetter, Dale O; Niu, Gang; Xie, Qingguo; Chen, Xiaoyuan

    2014-04-01

    RGD peptide-based radiotracers are well established as integrin αvβ3 imaging probes to evaluate tumor angiogenesis or tissue remodeling after ischemia or infarction. In order to optimize the labeling process and pharmacokinetics of the imaging probes, we synthesized three dimeric RGD peptides with or without PEGylation and performed in vivo screening. Radiolabeling was achieved through the reaction of F-18 aluminum-fluoride complex with the cyclic chelator, 1,4,7-triazacyclononane-1,4,7-triacetic acid (NOTA). Three imaging probes were synthesized as (18)F-AlF-NOTA-E[c(RGDfK)]2, (18)F-AlF-NOTA-PEG4-E[c(RGDfK)]2, and (18)F-AlF-NOTA-E[PEG4-c(RGDfk)]2. The receptor binding affinity was determined by competitive cell binding assay, and the stability was evaluated by mouse serum incubation. Tumor uptake and whole body distribution of the three tracers were compared through direct tissue sampling and PET quantification of U87MG tumor-bearing mice. All three compounds remained intact after 120 min incubation with mouse serum. They all had a rapid and relatively high tracer uptake in U87MG tumors with good target-to-background ratios. Compared with the other two tracers, (18)F-AlF-NOTA-E[PEG4-c(RGDfk)]2 had the highest tumor uptake and the lowest accumulation in the liver. The integrin receptor specificity was confirmed by co-injection of unlabeled dimeric RGD peptide. The rapid one-step radiolabeling strategy by the complexation of (18)F-aluminum fluoride with NOTA-peptide conjugates was successfully applied to synthesize three dimeric RGD peptides. Among the three probes developed, (18)F-AlF-NOTA-E[PEG4-c(RGDfk)]2 with relatively low liver uptake and high tumor accumulation appears to be a promising candidate for further translational research.

  11. Single-Cell Imaging Using Radioluminescence Microscopy Reveals Unexpected Binding Target for [18F]HFB.

    PubMed

    Kiru, Louise; Kim, Tae Jin; Shen, Bin; Chin, Frederick T; Pratx, Guillem

    2018-06-01

    Cell-based therapies are showing great promise for a variety of diseases, but remain hindered by the limited information available regarding the biological fate, migration routes and differentiation patterns of infused cells in trials. Previous studies have demonstrated the feasibility of using positron emission tomography (PET) to track single cells utilising an approach known as positron emission particle tracking (PEPT). The radiolabel hexadecyl-4-[ 18 F]fluorobenzoate ([ 18 F]HFB) was identified as a promising candidate for PEPT, due to its efficient and long-lasting labelling capabilities. The purpose of this work was to characterise the labelling efficiency of [ 18 F]HFB in vitro at the single-cell level prior to in vivo studies. The binding efficiency of [ 18 F]HFB to MDA-MB-231 and Jurkat cells was verified in vitro using bulk gamma counting. The measurements were subsequently repeated in single cells using a new method known as radioluminescence microscopy (RLM) and binding of the radiolabel to the single cells was correlated with various fluorescent dyes. Similar to previous reports, bulk cell labelling was significantly higher with [ 18 F]HFB (18.75 ± 2.47 dpm/cell, n = 6) than 2-deoxy-2-[ 18 F]fluoro-D-glucose ([ 18 F]FDG) (7.59 ± 0.73 dpm/cell, n = 7; p ≤ 0.01). However, single-cell imaging using RLM revealed that [ 18 F]HFB accumulation in live cells (8.35 ± 1.48 cpm/cell, n = 9) was not significantly higher than background levels (4.83 ± 0.52 cpm/cell, n = 12; p > 0.05) and was 1.7-fold lower than [ 18 F]FDG uptake in the same cell line (14.09 ± 1.90 cpm/cell, n = 13; p < 0.01). Instead, [ 18 F]HFB was found to bind significantly to fragmented membranes associated with dead cell nuclei, suggesting an alternative binding target for [ 18 F]HFB. This study demonstrates that bulk analysis alone does not always accurately portray the labelling efficiency, therefore highlighting the need for more routine screening of

  12. Comparison of the biological effects of {sup 18}F at different intracellular levels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kashino, Genro, E-mail: kashino@oita-u.ac.jp; Hayashi, Kazutaka; Douhara, Kazumasa

    Highlights: • We estimated the inductions of DNA DSB in cell treated with {sup 18}F-FDG. • We found that inductions of DNA DSB are dependent on accumulation of {sup 18}F in cell. • Accumulation of {sup 18}F in cell may be indispensable for risk estimation of PET. - Abstract: We herein examined the biological effects of cells treated with {sup 18}F labeled drugs for positron emission tomography (PET). The relationship between the intracellular distribution of {sup 18}F and levels of damaged DNA has yet to be clarified in detail. We used culture cells (Chinese Hamster Ovary cells) treated with twomore » types of {sup 18}F labeled drugs, fluorodeoxyglucose (FDG) and fluorine ion (HF). FDG efficiently accumulated in cells, whereas HF did not. To examine the induction of DNA double strand breaks (DSB), we measured the number of foci for 53BP1 that formed at the site of DNA DSB. The results revealed that although radioactivity levels were the same, the induction of 53BP1 foci was stronger in cells treated with {sup 18}F-FDG than in those treated with {sup 18}F-HF. The clonogenic survival of cells was significantly lower with {sup 18}F-FDG than with {sup 18}F-HF. We concluded that the efficient accumulation of {sup 18}F in cells led to stronger biological effects due to more severe cellular lethality via the induction of DNA DSB.« less

  13. Positron emitting nuclides and their synthetic incorporation in radiopharmaceuticals. [Labeled with /sup 11/C, /sup 13/N, and /sup 18/F

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fowler, J.S.

    /sup 11/C, /sup 13/N, and /sup 15/O has potential applicability to the study of metabolism in humans. Problems in the synthesis of radiopharmaceuticals labeled with /sup 11/C, /sup 13/N, and /sup 18/F are described: quality control, radiation exposure, carboxylic acids, glucose, amines, amino acids, nitrosources, fluoroethanol. 54 references. (DLC)

  14. N,N-dimethyl-2-(2-amino-4-(18)F-fluorophenylthio)-benzylamine (4-(18)F-ADAM): an improved PET radioligand for serotonin transporters.

    PubMed

    Shiue, Grace G; Choi, Seok-Rye; Fang, Ping; Hou, Catherine; Acton, Paul D; Cardi, Chris; Saffer, Janet R; Greenberg, Joel H; Karp, Joel S; Kung, Hank F; Shiue, Chyng-Yann

    2003-12-01

    There has been considerable interest in the development of PET radioligands that are useful for imaging serotonin transporter (SERT) in the living human brain. For the last decade, (11)C-(+)McN5652 has been the most promising PET agent for studying SERT in humans. However, this agent has some limitations. Recently, a new promising SERT PET radioligand, 3-(11)C-amino-4-(2-dimethylaminomethylphenylsulfanyl)benzonitrile, has been reported. We recently reported the synthesis of a new (18)F-labeled SERT PET radioligand, N,N-dimethyl-2-(2-amino-4-(18)F-fluorophenylthio)benzylamine (4-(18)F-ADAM), which may have advantages over (11)C-labeled radioligands. The purpose of this study was to evaluate this newly developed (18)F-labeled PET radioligand as a promising agent for studying SERT in the living human brain. This agent was evaluated by studying its in vitro binding to different monoamine transporters, its in vivo biodistributions in rats, its integrity and pharmacologic profiles in rat brain, and its distribution in a female baboon brain. In vitro binding assays showed that 4-F-ADAM displayed high affinity to SERT sites (inhibition constant = 0.081 nmol/L, using membrane preparations of LLC-PK1 cells expressing the specific transporter) and showed more than 1,000- and 28,000-fold selectivity for SERT over norepinephrine transporter and dopamine transporter, respectively. Biodistribution of 4-(18)F-ADAM in rats showed a high initial uptake and slow clearance in the brain (2.13%, 1.90%, and 0.95% injected dose per organ at 2, 30, and 60 min after intravenous injection, respectively), with the specific binding peaking at 2 h after injection (hypothalamus/cerebellum = 12.49). The uptake in blood, muscle, lung, kidney, and liver was also initially high but cleared rapidly. The radioactivity in the femur increases with time for 4-(18)F-ADAM, indicating that in vivo defluorination may occur. In vivo metabolism studies in rats showed that 4-(18)F-ADAM was not metabolized in

  15. [18F]F15599, a novel 5-HT1A receptor agonist, as a radioligand for PET neuroimaging.

    PubMed

    Lemoine, Laëtitia; Verdurand, Mathieu; Vacher, Bernard; Blanc, Elodie; Le Bars, Didier; Newman-Tancredi, Adrian; Zimmer, Luc

    2010-03-01

    The serotonin-1A (5-HT(1A)) receptor is implicated in the pathophysiology of major neuropsychiatric disorders. Thus, the functional imaging of 5-HT(1A) receptors by positron emission tomography (PET) may contribute to the understanding of its role in those pathologies and their therapeutics. These receptors exist in high- and low-affinity states and it is proposed that agonists bind preferentially to the high-affinity state of the receptor and therefore could provide a measure of the functional 5-HT(1A) receptors. Since all clinical PET 5-HT(1A) radiopharmaceuticals are antagonists, it is of great interest to develop a( 18)F labelled agonist. F15599 (3-chloro-4-fluorophenyl-(4-fluoro-4{[(5-methyl-pyrimidin-2-ylmethyl)-amino]-methyl}-piperidin-1-yl)-methanone) is a novel ligand with high affinity and selectivity for 5-HT(1A) receptors and is currently tested as an antidepressant. In pharmacological tests in rat, it exhibits preferential agonist activity at post-synaptic 5-HT(1A) receptors in cortical brain regions. Here, its nitro-precursor was synthesised and radiolabelled via a fluoronucleophilic substitution. Radiopharmacological evaluations included in vitro and ex vivo autoradiography in rat brain and PET scans on rats and cats. Results were compared with simultaneous studies using [(18)F]MPPF, a validated 5-HT(1A) antagonist radiopharmaceutical. The chemical and radiochemical purities of [(18)F]F15599 were >98%. In vitro [(18)F]F15599 binding was consistent with the known 5-HT(1A) receptors distribution (hippocampus, dorsal raphe nucleus, and notably cortical areas) and addition of Gpp(NH)p inhibited [(18)F]F15599 binding, consistent with a specific binding to G protein-coupled receptors. In vitro binding of [(18)F]F15599 was blocked by WAY100635 and 8-OH-DPAT, respectively, prototypical 5-HT(1A) antagonist and agonist. The ex vivo and in vivo studies demonstrated that the radiotracer readily entered the rat and the cat brain and generated few brain

  16. 18F-FPYBF-2, a new F-18 labelled amyloid imaging PET tracer: biodistribution and radiation dosimetry assessment of first-in-man 18F-FPYBF-2 PET imaging.

    PubMed

    Nishii, Ryuichi; Higashi, Tatsuya; Kagawa, Shinya; Okuyama, Chio; Kishibe, Yoshihiko; Takahashi, Masaaki; Okina, Tomoko; Suzuki, Norio; Hasegawa, Hiroshi; Nagahama, Yasuhiro; Ishizu, Koichi; Oishi, Naoya; Kimura, Hiroyuki; Watanabe, Hiroyuki; Ono, Masahiro; Saji, Hideo; Yamauchi, Hiroshi

    2018-05-01

    Recently, a benzofuran derivative for the imaging of β-amyloid plaques, 5-(5-(2-(2-(2- 18 F-fluoroethoxy)ethoxy)ethoxy)benzofuran-2-yl)- N-methylpyridin-2-amine ( 18 F-FPYBF-2) has been validated as a tracer for amyloid imaging and it was found that 18 F-FPYBF-2 PET/CT is a useful and reliable diagnostic tool for the evaluation of AD (Higashi et al. Ann Nucl Med, https://doi.org/10.1007/s12149-018-1236-1 , 2018). The aim of this study was to assess the biodistribution and radiation dosimetry of diagnostic dosages of 18 F-FPYBF-2 in normal healthy volunteers as a first-in-man study. Four normal healthy volunteers (male: 3, female: 1; mean age: 40 ± 17; age range 25-56) were included and underwent 18 F-FPYBF-2 PET/CT study for the evaluation of radiation exposure and pharmacokinetics. A 10-min dynamic PET/CT scan of the body (chest and abdomen) was performed at 0-10 min and a 15-min whole-body static scan was performed six times after the injection of 18 F-FPYBF-2. After reconstructing PET and CT image data, individual organ time-activity curves were estimated by fitting volume of interest data from the dynamic scan and whole-body scans. The OLINDA/EXM version 2.0 software was used to determine the whole-body effective doses. Dynamic PET imaging demonstrated that the hepatobiliary and renal systems were the principal pathways of clearance of 18 F-FPYBF-2. High uptake in the liver and the gall bladder, the stomach, and the kidneys were demonstrated, followed by the intestines and the urinary bladder. The ED for the adult dosimetric model was estimated to be 8.48 ± 1.25 µSv/MBq. The higher absorbed doses were estimated for the liver (28.98 ± 12.49 and 36.21 ± 15.64 µGy/MBq), the brain (20.93 ± 4.56 and 23.05 ± 5.03µ Gy/MBq), the osteogenic cells (9.67 ± 1.67 and 10.29 ± 1.70 µGy/MBq), the small intestines (9.12 ± 2.61 and 11.12 ± 3.15 µGy/MBq), and the kidneys (7.81 ± 2.62 and 8.71 ± 2.90 µGy/MBq) for

  17. Efficient synthesis of a fluorine-18 labeled biotin derivative.

    PubMed

    Claesener, Michael; Breyholz, Hans-Jörg; Hermann, Sven; Faust, Andreas; Wagner, Stefan; Schober, Otmar; Schäfers, Michael; Kopka, Klaus

    2012-11-01

    The natural occurring vitamin biotin, also known as vitamin H or vitamin B(7), plays a major role in various metabolic reactions. Caused by its high binding affinity to the protein avidin with a dissociation constant of about 10(-15)M the biotin-avidin system was extensively examined for multiple applications. We have synthesized a fluorine-18 labeled biotin derivative [(18)F]4 for a potential application in positron emission tomography (PET). Mesylate precursor 3 was obtained by an efficient two-step reaction via a copper catalyzed azide-alkyne cycloaddition (CuAAC) from easily accessible starting materials. [(18)F]4 was successfully synthesized by a nucleophilic radiofluorination of precursor 3. A biodistribution study by means of small-animal PET imaging in wt-mice was performed and serum stability was examined. Compound [(18)F]4 was obtained from precursor compound 3 with an average specific activity of 16GBq/μmol within 45min and a radiochemical yield of 45±5% (decay corrected). [(18)F]4 demonstrated only negligible decomposition in human serum. A qualitative binding study revealed the high affinity of the synthesized biotin derivative to avidin. Blocking experiments with native biotin showed that binding was site-specific. Biodistribution studies showed that [(18)F]4 was cleared quickly and efficiently from the body by hepatobiliary and renal elimination. An efficient synthesis for [(18)F]4 was established. In vivo characteristics were determined and demonstrated the pharmacokinetic behaviour of [(18)F]4. Copyright © 2012 Elsevier Inc. All rights reserved.

  18. Synthesis of substituted 2-(β-D-glucopyranosyl)-benzimidazoles and their evaluation as inhibitors of glycogen phosphorylase.

    PubMed

    Bokor, Éva; Szilágyi, Enikő; Docsa, Tibor; Gergely, Pál; Somsák, László

    2013-11-15

    Microwave assisted condensation of O-perbenzoylated C-(β-d-glucopyranosyl)formic acid with 1,2-diaminobenzenes in the presence of triphenylphosphite gave the corresponding O-protected 2-(β-d-glucopyranosyl)-benzimidazoles in moderate yields. O-Perbenzoylated C-(β-d-glucopyranosyl)formamide and -thioformamide were transformed into the corresponding ethyl C-(β-d-glucopyranosyl)formimidate and -thioformimidate, respectively, by Et3O·BF4. Treatment of the formimidate with 1,2-diaminobenzenes afforded O-protected 2-(β-d-glucopyranosyl)-benzimidazoles in good to excellent yields. Similar reaction of the thioformimidate gave these compounds in lower yields. The O-benzoyl protecting groups were removed by the Zemplén protocol. These test compounds were assayed against rabbit muscle glycogen phosphorylase (GP) b, the prototype of liver GP, the rate limiting enzyme of glycogen degradation. The best inhibitors were 2-(β-d-glucopyranosyl)-4-methyl-benzimidazole (Ki=2.8μM) and 2-(β-d-glucopyranosyl)-naphtho[2,3-d]imidazole (Ki=2.1μM) exhibiting a ∼3-4 times stronger binding than the unsubstituted parent compound. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. Heterogeneity in Intratumor Correlations of 18F-FDG, 18F-FLT, and 61Cu-ATSM PET in Canine Sinonasal Tumors

    PubMed Central

    Bradshaw, Tyler J.; Bowen, Stephen R.; Jallow, Ngoneh; Forrest, Lisa J.; Jeraj, Robert

    2014-01-01

    Intratumor heterogeneity in biologic properties and in relationships between various phenotypes may present a challenge for biologically targeted therapies. Understanding the relationships between different phenotypes in individual tumor types could help inform treatment selection. The goal of this study was to characterize spatial correlations of glucose metabolism, proliferation, and hypoxia in 2 histologic types of tumors. Methods Twenty canine veterinary patients with spontaneously occurring sinonasal tumors (13 carcinomas and 7 sarcomas) were imaged with 18F-FDG, 18F-labeled 39-deoxy-39-fluorothymidine (18F-FLT), and 61Cu-labeled diacetyl-bis(N4-methylthiosemicarbazone) (61Cu-ATSM) PET/CT on 3 consecutive days. Precise positioning and immobilization techniques coupled with anesthesia enabled motionless scans with repeatable positioning. Standardized uptake values (SUVs) of gross sarcoma and carcinoma volumes were compared by use of Mann– Whitney U tests. Patient images were rigidly registered together, and intratumor tracer uptake distributions were compared. Voxel-based Spearman correlation coefficients were used to quantify intertracer correlations, and the correlation coefficients of sarcomas and carcinomas were compared. The relative overlap of the highest uptake volumes of the 3 tracers was quantified, and the values were compared for sarcomas and carcinomas. Results Large degrees of heterogeneity in SUV measures and phenotype correlations were observed. Carcinoma and sarcoma tumors differed significantly in SUV measures, with carcinoma tumors having significantly higher 18F-FDG maximum SUVs than sarcoma tumors (11.1 vs. 5.0; P = 0.01) as well as higher 61Cu-ATSM mean SUVs (2.6 vs. 1.2; P = 0.02). Carcinomas had significantly higher population-averaged Spearman correlation coefficients than sarcomas in comparisons of 18F-FDG and 18F-FLT (0.80 vs. 0.61; P = 0.02), 18F-FLT and 61Cu-ATSM (0.83 vs. 0.38; P < 0.0001), and 18F-FDG and 61Cu-ATSM (0.82 vs. 0

  20. Synthesis of 3-O-(beta-D-xylopyranosyl-(1-->2)-beta-D-glucopyranosyl)-3'-O-(beta-D-glucopyranosyl)tamarixetin, the putative structure of aescuflavoside A from the seeds of Aesculus chinensis.

    PubMed

    Zhu, Cunsheng; Peng, Wenjie; Li, Yuwen; Han, Xiuwen; Yu, Biao

    2006-06-12

    3-O-(beta-D-xylopyranosyl-(1-->2)-beta-D-glucopyranosyl)-3'-O-(beta-D-glucopyranosyl)tamarixetin, the putative flavonal glycoside named aescuflavoside A, isolated from the seeds of Aesculus chinensis, is synthesized via regioselective glycosylation of 7-O-benzyltamarixetin with glycosyl bromides under phase-transfer-catalyzed conditions.

  1. Quantification of Kryptofix 2.2.2 in [18F]fluorine-labelled radiopharmaceuticals by rapid-resolution liquid chromatography.

    PubMed

    Lao, Yexing; Yang, Cuiping; Zou, Wei; Gan, Manquan; Chen, Ping; Su, Weiwei

    2012-05-01

    The cryptand Kryptofix 2.2.2 is used extensively as a phase-transfer reagent in the preparation of [18F]fluoride-labelled radiopharmaceuticals. However, it has considerable acute toxicity. The aim of this study was to develop and validate a method for rapid (within 1 min), specific and sensitive quantification of Kryptofix 2.2.2 at trace levels. Chromatographic separations were carried out by rapid-resolution liquid chromatography (Agilent ZORBAX SB-C18 rapid-resolution column, 2.1 × 30 mm, 3.5 μm). Tandem mass spectra were acquired using a triple quadrupole mass spectrometer equipped with an electrospray ionization interface. Quantitative mass spectrometric analysis was conducted in positive ion mode and multiple reaction monitoring mode for the m/z 377.3 → 114.1 transition for Kryptofix 2.2.2. The external standard method was used for quantification. The method met the precision and efficiency requirements for PET radiopharmaceuticals, providing satisfactory results for specificity, matrix effect, stability, linearity (0.5-100 ng/ml, r(2)=0.9975), precision (coefficient of variation < 5%), accuracy (relative error < ± 3%), sensitivity (lower limit of quantification=0.5 ng) and detection time (<1 min). Fluorodeoxyglucose (n=6) was analysed, and the Kryptofix 2.2.2 content was found to be well below the maximum permissible levels approved by the US Food and Drug Administration. The developed method has a short analysis time (<1 min) and high sensitivity (lower limit of quantification=0.5 ng/ml) and can be successfully applied to rapid quantification of Kryptofix 2.2.2 at trace levels in fluorodeoxyglucose. This method could also be applied to other [18F]fluorine-labelled radiopharmaceuticals that use Kryptofix 2.2.2 as a phase-transfer reagent.

  2. Proton irradiation of [18O]O2: production of [18F]F2 and [18F]F2 + [18F] OF2.

    PubMed

    Bishop, A; Satyamurthy, N; Bida, G; Hendry, G; Phelps, M; Barrio, J R

    1996-04-01

    The production of 18F electrophilic reagents via the 18O(p,n)18F reaction has been investigated in small-volume target bodies made of aluminum, copper, gold-plated copper and nickel, having straight or conical bore shapes. Three irradiation protocols-single-step, two-step and modified two-step-were used for the recovery of the 18F activity. The single-step irradiation protocol was tested in all the target bodies. Based on the single-step performance, aluminum targets were utilized extensively in the investigation of the two-step and modified two-step irradiation protocols. With an 11-MeV cyclotron and using the two-step irradiation protocol, > 1Ci [18F]F2 was recovered reproducibly from an aluminum target body. Probable radical mechanisms for the formation of OF2 and FONO2 (fluorine nitrate) in the single-step and modified two-step targets are proposed based on the amount of ozone generated and the nitrogen impurity present in the target gases, respectively.

  3. 27 CFR 18.55 - Label.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2014-04-01 2014-04-01 false Label. 18.55 Section 18.55 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY ALCOHOL PRODUCTION OF VOLATILE FRUIT-FLAVOR CONCENTRATE Operations § 18.55 Label. Each container...

  4. 27 CFR 18.55 - Label.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2012-04-01 2012-04-01 false Label. 18.55 Section 18.55 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS PRODUCTION OF VOLATILE FRUIT-FLAVOR CONCENTRATE Operations § 18.55 Label. Each container...

  5. 27 CFR 18.55 - Label.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Label. 18.55 Section 18.55 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS PRODUCTION OF VOLATILE FRUIT-FLAVOR CONCENTRATE Operations § 18.55 Label. Each container...

  6. 27 CFR 18.55 - Label.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2013-04-01 2013-04-01 false Label. 18.55 Section 18.55 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY ALCOHOL PRODUCTION OF VOLATILE FRUIT-FLAVOR CONCENTRATE Operations § 18.55 Label. Each container...

  7. (S)-4-(3-18F-fluoropropyl)-L-glutamic acid: an 18F-labeled tumor-specific probe for PET/CT imaging--dosimetry.

    PubMed

    Smolarz, Kamilla; Krause, Bernd Joachim; Graner, Frank-Philipp; Wagner, Franziska Martina; Hultsch, Christina; Bacher-Stier, Claudia; Sparks, Richard B; Ramsay, Susan; Fels, Lüder M; Dinkelborg, Ludger M; Schwaiger, Markus

    2013-06-01

    The glutamic acid derivative (S)-4-(3-(18)F-Fluoropropyl)-l-glutamic acid ((18)F-FSPG, alias BAY 94-9392), a new PET tracer for the detection of malignant diseases, displayed promising results in non-small cell lung cancer patients. The aim of this study was to provide dosimetry estimates for (18)F-FSPG based on human whole-body PET/CT measurements. (18)F-FSPG was prepared by a fully automated 2-step procedure and purified by a solid-phase extraction method. PET/CT scans were obtained for 5 healthy volunteers (mean age, 59 y; age range, 51-64 y; 2 men, 3 women). Human subjects were imaged for up to 240 min using a PET/CT scanner after intravenous injection of 299 ± 22.5 MBq of (18)F-FSPG. Image quantification, time-activity data modeling, estimation of normalized number of disintegrations, and production of dosimetry estimates were performed using the RADAR (RAdiation Dose Assessment Resource) method for internal dosimetry and in general concordance with the methodology and principles as presented in the MIRD 16 document. Because of the renal excretion of the tracer, the absorbed dose was highest in the urinary bladder wall and kidneys, followed by the pancreas and uterus. The individual organ doses (mSv/MBq) were 0.40 ± 0.058 for the urinary bladder wall, 0.11 ± 0.011 for the kidneys, 0.077 ± 0.020 for the pancreas, and 0.030 ± 0.0034 for the uterus. The calculated effective dose was 0.032 ± 0.0034 mSv/MBq. Absorbed dose to the bladder and the effective dose can be reduced significantly by frequent bladder-voiding intervals. For a 0.75-h voiding interval, the bladder dose was reduced to 0.10 ± 0.012 mSv/MBq, and the effective dose was reduced to 0.015 ± 0.0010 mSv/MBq. On the basis of the distribution and biokinetic data, the determined radiation dose for (18)F-FSPG was calculated to be 9.5 ± 1.0 mSv at a patient dose of 300 MBq, which is of similar magnitude to that of (18)F-FDG (5.7 mSv). The effective dose can be reduced to 4.5 ± 0.30 mSv (at 300 MBq

  8. Feasibility of myocardial PET imaging using a benzylguanidine analog: meta-(3-[18F]fluoropropyl)benzylguanidine ([18F]mFPBG).

    PubMed

    Woo, Sang-Keun; Moon, Byung Seok; Kim, Bom Sahn; Kim, Min Hwan; Lee, Yong Jin; Jung, Jae Ho; Lee, Kyo Chul; Seo, Youngho; Kim, Wook; Lim, Sang Moo; Lee, Byung Chul; Kim, Sang Eun

    2018-05-03

    Global and regional sympathetic activity in the heart can be evaluated using [ 123 I]meta-iodobenzylguanidine ([ 123 I]mIBG) imaging. However, [ 123 I]mIBG is associated with low image spatial resolution and sensitivity in cardiac imaging. We investigated the capability of an F-18-labeled mIBG derivative, meta-(3-[ 18 F]fluoropropyl)benzylguanidine ([ 18 F]mFPBG), for identifying ischemic and viable myocardium in a rat model of myocardial infarction. The ex vivo biodistribution and in vivo metabolic stability of [ 18 F]mFPBG were investigated in Sprague-Dawley rats. Selective cardiac adrenergic activation was confirmed via a blocking experiment involving pretreatment with desipramine (2 mg kg -1 ), followed by the administration of [ 18 F]mFPBG. Imaging properties of [ 18 F]mFPBG were compared with those of traditional cardiac imaging radiotracers ([ 123 I]mIBG and [ 99m Tc]MIBI) in a rat model of myocardial infarction. Non-invasive image-based measurements of infarct sizes were then compared with histological findings by using Bland-Altman analysis. The differences in infarct sizes determined using histological analysis and [ 18 F]mFPBG PET were -2.55 ± 4.99% (range: -12.33 to 7.22), -2.35 ± 3.32% (range: -8.87 to 4.16), and -3.15 ± 6.16% (range: -15.24 to 8.93) at 5, 20, and 40 min, respectively. Furthermore, [ 18 F]mFPBG PET was superior to traditional imaging methods in assessing the degree of ischemia in areas of myocardial infarction, as well as the actual infarct size. Compared to [ 123 I]mIBG, [ 18 F]mFPBG showed improved spatial resolution and sensitivity in a rat model of myocardial infarction. This result suggested that [ 18 F]mFPBG is a promising cardiac PET imaging agent for potential diagnostic application in PET cardiology. Copyright © 2018 Elsevier Inc. All rights reserved.

  9. A New Highly Reactive and Low Lipophilicity Fluorine-18 Labeled Tetrazine Derivative for Pretargeted PET Imaging

    PubMed Central

    2015-01-01

    A new 18F-labeled tetrazine derivative was developed aiming at optimal radiochemistry, fast reaction kinetics in inverse electron-demand Diels–Alder cycloaddition (IEDDA), and favorable pharmacokinetics for in vivo bioorthogonal chemistry. The radiolabeling of the tetrazine was achieved in high yield, purity, and specific activity under mild reaction conditions via conjugation with 5-[18F]fluoro-5-deoxyribose, providing a glycosylated tetrazine derivative with low lipophilicity. The 18F-tetrazine showed fast reaction kinetics toward the most commonly used dienophiles in IEDDA reactions. It exhibited excellent chemical and enzymatic stability in mouse plasma and in phosphate-buffered saline (pH 7.41). Biodistribution in mice revealed favorable pharmacokinetics with major elimination via urinary excretion. The results indicate that the glycosylated 18F-labeled tetrazine is an excellent candidate for in vivo bioorthogonal chemistry applications in pretargeted PET imaging approaches. PMID:26819667

  10. Radiosynthesis of [18F]Trifluoroalkyl Groups: Scope and Limitations

    PubMed Central

    Riss, P. J.

    2014-01-01

    The present paper is concerned with radiochemical methodology to furnish the trifluoromethyl motif labelled with 18F. Literature spanning the last four decades is comprehensively reviewed and radiochemical yields and specific activities are discussed. PMID:25110676

  11. PET imaging of osteosarcoma in dogs using a fluorine-18-labeled monoclonal antibody fab fragment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Page, R.L.; Garg, P.K.; Gard, S.

    Four dogs with histologically confirmed osteogenic sarcoma were studied with PET following intravenous injection of the {sup 18}F-labeled Fab fragment of TP-3, a monoclonal antibody specific for human and canine osteosarcomas. The antibody fragment was labeled using the N-succinimidyl (8-(4{prime}-({sup 18}F)fluorobenzyl)amino)suberate acylation agent. Blood clearance of activity was biphasic in all dogs but half-times were variable (T{sub 1/2{beta}} = 2-13 hr). Catabolism of labeled Fab was reflected by the decrease in protein-associated activity in serum from more than 90% at 1 min to 60%-80% at 4 hr. PET images demonstrated increased accumulation of {sup 18}F at the primary tumor sitemore » relative to normal contralateral bone in one dog as early as 15 min after injection. Biopsies obtained after euthanasia indicated higher uptake at the edges of the tumor as observed on the PET scans. Tumor uptake was 1-3 x 10{sup -3}% injected dose/g, a level similar to that reported for other Fab fragments in human tumors. In the three dogs with metastatic disease, early PET images reflected activity in the blood pool but later uptake was observed in suspected metastatic sites. These results, although preliminary, suggest that PET imaging of {sup 18}F-labeled antibody fragments is feasible and that dogs with spontaneous tumors could be a valuable model for preclinical research with radioimmunoconjugates. 34 refs., 6 figs., 2 tabs.« less

  12. Synthesis and dopamine transporter imaging in rhesus monkeys with fluorine-18 labeled FECT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Keil, R.; Hoffman, J.M.; Eschima, D.

    1996-05-01

    Parkinson`s patients have been shown to suffer a 60-80% loss of dopamine transporters in the substantia nigra and striatum. Dopamine transporter ligands labeled with fluorine-18 (t {1/2}=110 min) are attractive probes for measuring the density of dopamine transporter sites n the striatum for the diagnosis and evaluation of Parkinson`s patients by PET. We have synthesized (Ki = 32 nM vs RTI-55), fluorine-18 labeled 2{beta}-carbomethoxy-3{beta}(4-chlorophenyl)-8-(3-fluoropropyl)nortropane (FECT), with favorable kinetics as a potential dopamine transporter PET imaging agent. Treatment of 2{beta}-carbomethoxy-3{beta}-(4-chlorophenyl)nortropane (1) with 1-bromo-2-fluoroethane (2) in CH3CN at 80{degrees}C gave FECT (3). [F-18]FECT (3) was prepared by treating 1,2-ditosyloxyethane (4) with NCAmore » K[F-18]/K222 (365 mCi) for 5 min in CH3CN at 85{degrees}C to give [F-18] 1-fluoro-2-tosyloxyethane (5) (175 mCi)in 59% E.O.B. yield. Coupling of [F-18] 5 with 1 in DMF at 135 {degrees}C for 45 min gave [F-18]FECT (41 mCi) in 25% yield E.O.B. following HPLC purification in a total synthesis time of 122 min. [F-18] 5 was >99% radiochemically pure with a specific activity of 5 Ci/{mu}mole. Following intravenous administration to a rhesus monkey [F-18]FECT (8.13 mCi) showed a peak uptake at 30 min in the striatum (S) followed by a slow clearance and a rapid washout from the cerebellum to afford a high S/C ratio = 11.0 at 125 min. Radio-HPLC analysis of the ether extracts form plasma samples for radioactive metabolites detected only the presence of [F-18]FECT. These results suggest that FECT is an Research supported by DOE.« less

  13. Retention Kinetics of the 18F-Labeled Sympathetic Nerve PET Tracer LMI1195: Comparison with 11C-Hydroxyephedrine and 123I-MIBG.

    PubMed

    Werner, Rudolf A; Rischpler, Christoph; Onthank, David; Lapa, Constantin; Robinson, Simon; Samnick, Samuel; Javadi, Mehrbod; Schwaiger, Markus; Nekolla, Stephan G; Higuchi, Takahiro

    2015-09-01

    (18)F-N-[3-bromo-4-(3-fluoro-propoxy)-benzyl]-guanidine ((18)F-LMI1195) is a new PET tracer designed for noninvasive assessment of sympathetic innervation of the heart. The (18)F label facilitates the imaging advantages of PET over SPECT technology while allowing centralized manufacturing. Highly specific neural uptake of (18)F-LMI1195 has previously been established, but the retention kinetics are not yet fully understood. Healthy New Zealand White rabbits were studied with (18)F-LMI1195 using a small-animal PET system. Dynamic 40-min chest scans were started just before intravenous bolus injection of (18)F-LMI1195. Imaging was performed under norepinephrine transport inhibition with desipramine pretreatment, a 1.5 mg/kg desipramine chase administered 10 min after tracer injection, and saline treatment of controls. As a reference, cardiac uptake of (11)C-hydroxyephedrine and (123)I-metaiodobenzylguanidine ((123)I-MIBG) was examined by PET and planar scintigraphy, respectively. Cardiac uptake of all 3 tracers was inhibited by pretreatment with desipramine. Stable cardiac tracer retention was delineated by dynamic PET in control rabbits for (11)C-hydroxyephedrine (washout rate, 0.42% ± 0.57%/min) and (18)F-LMI1195 (washout rate, 0.058% ± 0.28%/min). A desipramine chase increased (11)C-hydroxyephedrine washout from the heart (2.43% ± 0.15%/min, P < 0.001), whereas (18)F-LMI1195 washout was not influenced (0.059% ± 0.11%/min, not statistically significant). Additionally, a desipramine chase did not change the cardiac (123)I-MIBG uptake (delayed heart-to-mediastinum ratio, 1.99 ± 0.12 (desipramine chase) vs. 2.05 ± 0.16 (controls), not statistically significant). In vivo norepinephrine transporter (NET) blockade with desipramine confirmed specific neural uptake of (18)F-LMI1195, (11)C-hydroxyephedrine, and (123)I-MIBG in rabbit hearts. (11)C-hydroxyephedrine cardiac retention was sensitive to a NET inhibitor chase, indicating a cycle of continuous NET uptake and

  14. Fluorinase: a tool for the synthesis of ¹⁸F-labeled sugars and nucleosides for PET.

    PubMed

    Onega, Mayca; Winkler, Margit; O'Hagan, David

    2009-08-01

    There is an increasing interest in the preparation of (18)F-labeled radiopharmaceuticals with potential applications in PET for medicinal imaging. Appropriate synthetic methods require a quick and efficient route in which to incorporate the (18)F into a ligand, due to the relatively short half-life of the (18)F isotope. Enzymatic methods are rare in this area; however, the discovery of a fluorinating enzyme from Streptomyces cattleya (EC 2.5.1.63) has opened up the possibility of the enzymatic synthesis and formation of C-(18)F bonds from the [(18)F]fluoride ion. In this article, the development of enzymatic preparations of (18)F-labeled sugars and nucleosides as potential radiotracers using the fluorinase from S. cattleya for PET applications is reviewed. Enzymatic reactions are not traditional in PET synthesis, but this enzyme has some attractive features. The enzyme is available in an overexpressed form from Escherichia coli and it is relatively stable and can be easily purified and manipulated. Most notably, it utilizes [(18)F] fluoride, the form of the isotope normally generated by the cyclotron and usually in very high specific radioactivity. The disadvantage with the enzyme is that it is substrate specific; however, when the fluorinase is used in combination biotransformations with a second or third enzyme, then a range of radiolabeled nucleosides and ribose sugars can be prepared. The fluorinase enzyme has emerged as a curiosity from biosynthesis studies, but it now has some potential as a new catalyst for (18)F incorporation for PET syntheses. The focus is now on delivering a user-friendly catalyst to the PET synthesis community and establishing a clinical role for some of the (18)F-labeled molecules available using this technology.

  15. 18F-FPYBF-2, a new F-18-labelled amyloid imaging PET tracer: first experience in 61 volunteers and 55 patients with dementia.

    PubMed

    Higashi, Tatsuya; Nishii, Ryuichi; Kagawa, Shinya; Kishibe, Yoshihiko; Takahashi, Masaaki; Okina, Tomoko; Suzuki, Norio; Hasegawa, Hiroshi; Nagahama, Yasuhiro; Ishizu, Koichi; Oishi, Naoya; Kimura, Hiroyuki; Watanabe, Hiroyuki; Ono, Masahiro; Saji, Hideo; Yamauchi, Hiroshi

    2018-04-01

    Recently, we developed a benzofuran derivative for the imaging of β-amyloid plaques, 5-(5-(2-(2-(2- 18 F-fluoroethoxy)ethoxy)ethoxy)benzofuran-2-yl)-N-methylpyridin-2-amine ( 18 F-FPYBF-2) (Ono et al., J Med Chem 54:2971-9, 2011). The aim of this study was to assess the feasibility of 18 F-FPYBF-2 as an amyloid imaging PET tracer in a first clinical study with healthy volunteers and patients with various dementia and in comparative dual tracer study using 11 C-Pittsburgh Compound B ( 11 C-PiB). 61 healthy volunteers (age: 53.7 ± 13.1 years old; 19 male and 42 female; age range 24-79) and 55 patients with suspected dementia [Alzheimer's Disease (AD); early AD: n = 19 and moderate stage AD: n = 8, other dementia: n = 9, mild cognitive impairment (MCI): n = 16, cognitively normal: n = 3] for first clinical study underwent static head PET/CT scan using 18 F - FPYBF-2 at 50-70 min after injection. 13 volunteers and 14 patients also underwent dynamic PET scan at 0-50 min at the same instant. 16 subjects (volunteers: n = 5, patients with dementia: n = 11) (age: 66.3 ± 14.2 years old; 10 males and 6 females) were evaluated for comparative study (50-70 min after injection) using 18 F-FPYBF-2 and 11 C-PiB on separate days, respectively. Quantitative analysis of mean cortical uptake was calculated using Mean Cortical Index of SUVR (standardized uptake value ratio) based on the established method for 11 C-PiB analysis using cerebellar cortex as control. Studies with healthy volunteers showed that 18 F-FPYBF-2 uptake was mainly observed in cerebral white matter and that average Mean Cortical Index at 50-70 min was low and stable (1.066 ± 0.069) basically independent from age or gender. In patients with AD, 18 F-FPYBF-2 uptake was observed both in cerebral white and gray matter, and Mean Cortical Index was significantly higher (early AD: 1.288 ± 0.134, moderate AD: 1.342 ± 0.191) than those of volunteers and other

  16. [18F]Fluorophenylazocarboxylates: Design and Synthesis of Potential Radioligands for Dopamine D3 and μ-Opioid Receptor

    PubMed Central

    2017-01-01

    18F-Labeled building blocks from the type of [18F]fluorophenylazocarboxylic-tert-butyl esters offer a rapid, mild, and reliable method for the 18F-fluoroarylation of biomolecules. Two series of azocarboxamides were synthesized as potential radioligands for dopamine D3 and the μ-opioid receptor, revealing compounds 3d and 3e with single-digit and sub-nanomolar affinity for the D3 receptor and compound 4c with only micromolar affinity for the μ-opioid receptor, but enhanced selectivity for the μ-subtype in comparison to the lead compound AH-7921. A “minimalist procedure” without the use of a cryptand and base for the preparation of 4-[18F]fluorophenylazocarboxylic-tert-butyl ester [18F]2a was established, together with the radiosynthesis of methyl-, methoxy-, and phenyl-substituted derivatives ([18F]2b–f). With the substituted [18F]fluorophenylazocarbylates in hand, two prototype azocarboxylates radioligands were synthesized by 18F-fluoroarylation, namely the methoxy azocarboxamide [18F]3d as the D3 receptor radioligand and [18F]4a as a prototype structure of the μ-opioid receptor radioligand. By introducing the new series of [18F]fluorophenylazocarboxylic-tert-butyl esters, the method of 18F-fluoroarylation was significantly expanded, thereby demonstrating the versatility of 18F-labeled phenylazocarboxylates for the design of potential radiotracers for positron emission tomography . PMID:29479577

  17. Preclinical characterization of 18F-MAA, a novel PET surrogate of 99mTc-MAA.

    PubMed

    Wu, Shih-Yen; Kuo, Jia-Wei; Chang, Tien-Kuei; Liu, Ren-Shen; Lee, Rheun-Chuan; Wang, Shyh-Jen; Lin, Wuu-Jyh; Wang, Hsin-Ell

    2012-10-01

    (99m)Tc-labeled macroaggregated albumin ((99m)Tc-MAA) scintigraphy scan is routinely performed for lung perfusion imaging and for the assessment of in vivo distribution of (90)Y-labeled SIR-Spheres prior to selective internal radiation treatment for hepatocellular carcinoma. Positron emission tomography (PET) imaging is superior to gamma scintigraphy in terms of sensitivity, spatial resolution and accuracy of quantification. This study reported that (18)F-labeled macroaggregated albumin ((18)F-MAA) is an ideal PET imaging surrogate for (99m)Tc-MAA. (18)F-MAA was prepared from the commercial MAA kit via a one-step conjugation with N-succinimidyl 4-(18)F-fluorobenzoate ((18)F-SFB). The biodistribution study and microPET/microSPECT imaging were conducted in normal SD rats after intravenous injection of (18)F-MAA/(99m)Tc-MAA. A comparison study of these two radiotracers was performed after co-injection via the intrahepatic arterial in a N1S1 hepatoma-bearing SD rat model. The optimal condition for (18)F-MAA preparation is coupling MAA (0.5mg) with (18)F-SFB at 45°C for 5 min in a phosphate buffer of pH 8.5. (18)F-MAA was prepared in 60 min with high radiochemical yield (30%-35%) and high radiochemical purity (>95%). The in vivo distribution of (18)F-MAA after intravenous injection meets the specifications of MAA depicted in European Pharmacopeia. Our study demonstrated excellent correlation between (18)F-MAA and (99m)Tc-MAA in the regional distribution of tumor, liver and lungs (R(2)=0.965, 0.886 and 0.991, respectively), and also in the tumor-to-liver and tumor-to-lungs ratio (R(2)=0.965 and 0.987, respectively) in a N1S1 hepatoma-bearing SD rat model. The organ uptakes derived from animal PET/CT and SPECT/CT imaging after administration of these two tracers were in accordance with those obtained in the distribution studies. Starting from commercial MAA kit, an efficient preparation of (18)F-MAA was successfully established. Highly correlated, almost parallel

  18. Fast and repetitive in-capillary production of [18F]FDG.

    PubMed

    Wester, Hans-Jürgen; Schoultz, Bent Wilhelm; Hultsch, Christina; Henriksen, Gjermund

    2009-04-01

    The increasing demand for radiopharmaceuticals to be provided reproducibly and flexibly with high frequency for clinical application and animal imaging would be better met by improved or even new strategies for automated tracer production. Radiosynthesis in microfluidic systems, i.e. narrow tubing with a diameter of approximately 50-500 microm, holds promise for providing the means for repetitive multidose and multitracer production. In this study, the performance of a conceptually simple microfluidic device integrated into a fully automated synthesis procedure for in-capillary radiosynthesis (ICR) of clinical grade [(18)F]FDG was evaluated. The instrumental set-up consisted of pumps for reagent and solvent delivery into small mixing chambers, micro-fluidic capillaries, in-process radioactivity monitoring, solid-phase extraction and on-column deprotection of the (18)F-labelled intermediate followed by on-line formulation of [(18)F]FDG. In-capillary(18)F-fluorination of 2.1 micromol 1,3,4,6-tetra-O-acetyl-2-O-trifluoromethanesulphonyl-beta-D-mannopyranose (TATM; precursor for [(18)F]FDG) in acetonitrile (MeCN) at a flow rate of 0.3 ml/min within 40 s and subsequent on-line hydrolysis of the intermediate by treatment with 0.3 M NaOH for 1 min at 40 degrees C resulted in a radiochemical yield of 88 +/- 4% within <7 min. Reproducibility, robustness and suitability as a fast and efficient radiopharmaceutical research tool for (18)F-fluorination was demonstrated by eight independent, sequentially performed ICRs which provided identical tracer quality (radiochemical purity >97%, MeCN <5 microg/ml) and similar absolute yields (approximately 1.4 GBq). The described ICR process is a simple and efficient alternative to classic radiotracer production systems and provides a comparatively cheap instrumental methodology for the repetitive production of [(18)F]FDG with remarkably high efficiency and high yield under fully automated conditions. Although the results concerning the

  19. Synthesis and preclinical characterization of 1-(6'-deoxy-6'-[18F]fluoro-β-d-allofuranosyl)-2-nitroimidazole (β-6'-[18F]FAZAL) as a positron emission tomography radiotracer to assess tumor hypoxia.

    PubMed

    Wanek, Thomas; Kreis, Katharina; Križková, Petra; Schweifer, Anna; Denk, Christoph; Stanek, Johann; Mairinger, Severin; Filip, Thomas; Sauberer, Michael; Edelhofer, Patricia; Traxl, Alexander; Muchitsch, Viktoria E; Mereiter, Kurt; Hammerschmidt, Friedrich; Cass, Carol E; Damaraju, Vijaya L; Langer, Oliver; Kuntner, Claudia

    2016-11-01

    Positron emission tomography (PET) using fluorine-18 ( 18 F)-labeled 2-nitroimidazole radiotracers has proven useful for assessment of tumor oxygenation. However, the passive diffusion-driven cellular uptake of currently available radiotracers results in slow kinetics and low tumor-to-background ratios. With the aim to develop a compound that is actively transported into cells, 1-(6'-deoxy-6'-[ 18 F]fluoro-β-d-allofuranosyl)-2-nitroimidazole (β-[ 18 F]1), a putative nucleoside transporter substrate, was synthetized by nucleophilic [ 18 F]fluoride substitution of an acetyl protected labeling precursor with a tosylate leaving group (β-6) in a final radiochemical yield of 12±8% (n=10, based on [ 18 F]fluoride starting activity) in a total synthesis time of 60min with a specific activity at end of synthesis of 218±58GBq/μmol (n=10). Both radiolabeling precursor β-6 and unlabeled reference compound β-1 were prepared in multistep syntheses starting from 1,2:5,6-di-O-isopropylidene-α-d-allofuranose. In vitro experiments demonstrated an interaction of β-1 with SLC29A1 and SLC28A1/2/3 nucleoside transporter as well as hypoxia specific retention of β-[ 18 F]1 in tumor cell lines. In biodistribution studies in healthy mice β-[ 18 F]1 showed homogenous tissue distribution and excellent metabolic stability, which was unaffected by tissue oxygenation. PET studies in tumor bearing mice showed tumor-to-muscle ratios of 2.13±0.22 (n=4) at 2h after administration of β-[ 18 F]1. In ex vivo autoradiography experiments β-[ 18 F]1 distribution closely matched staining with the hypoxia marker pimonidazole. In conclusion, β-[ 18 F]1 shows potential as PET hypoxia radiotracer which merits further investigation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Structure Dependence of Long-Chain [18F]Fluorothia Fatty Acids as Myocardial Fatty Acid Oxidation Probes

    PubMed Central

    Pandey, Mukesh K.; Belanger, Anthony P.; Wang, Shuyan; DeGrado, Timothy R.

    2012-01-01

    In-vivo imaging of regional fatty acid oxidation (FAO) rates would have considerable potential for evaluation of mammalian diseases. We have synthe sized and evaluated 18F-labeled thia fatty acid analogues as metabolically trapped FAO probes to understand the effect of chain length, degree of unsaturation and placement of the thia-substituent on myocardial uptake and retention. 18-[18F]fluoro-4-thia-(9Z)-octadec-9-enoic acid (3) showed excellent heart:background radioactivity concentration ratios along with highest retention in heart and liver. Pretreatment of rats with the CPT-1 inhibitor, POCA, caused >80% reduction in myocardial uptake of 16-[18F]fluoro-4-thia-hexadecanoic acid (2), and 3 indicating high specificity for FAO. In contrast, 18-[18F]fluoro-4-thia-octadecanoic acid (4), showed dramatically reduced myocardial uptake and blunted response to POCA. 18-[18F]fluoro-6-thia-octadecanoic acid (5), showed moderate myocardial uptake and no sensitivity of myocardial uptake to POCA. The results demonstrate relationships between structures of 18F-labelled thia fatty acid and uptake, and their utility as FAO probes in various tissues. PMID:23153307

  1. Novel methodology for labelling mesoporous silica nanoparticles using the 18F isotope and their in vivo biodistribution by positron emission tomography

    NASA Astrophysics Data System (ADS)

    Rojas, Santiago; Gispert, Juan Domingo; Menchón, Cristina; Baldoví, Herme G.; Buaki-Sogo, Mireia; Rocha, Milagros; Abad, Sergio; Victor, Victor Manuel; García, Hermenegildo; Herance, José Raúl

    2015-03-01

    Nanoparticles have been proposed for several biomedical applications due to their potential as drug carriers, diagnostic and therapeutic agents. However, only a few of them have been approved for their use in humans. In order to gauge the potential applicability of a specific type of nanoparticle, in vivo biodistribution studies to characterize their pharmacokinetic properties are essential. In this regard, mesoporous silica nanoparticles (30-130 nm) have been functionalized with amino groups in order to react with N-succinimidyl 4-[18F]fluorobenzoate and thus anchor the 18F positron emission isotope by using a novel and easy labelling strategy. In vivo biodistribution was characterized in mice after intravenous administration of radiolabelled nanoparticles by positron emission tomography. Our results indicated that radiolabelled mesoporous silica nanoparticles were excreted into bile and urine and accumulated mainly in the organs of the reticuloendothelial system and lungs.

  2. Detection of osseous metastasis by 18F-NaF/18F-FDG PET/CT versus CT alone.

    PubMed

    Sampath, Srinath C; Sampath, Srihari C; Mosci, Camila; Lutz, Amelie M; Willmann, Juergen K; Mittra, Erik S; Gambhir, Sanjiv S; Iagaru, Andrei

    2015-03-01

    Sodium fluoride PET (18F-NaF) has recently reemerged as a valuable method for detection of osseous metastasis, with recent work highlighting the potential of coadministered 18F-NaF and 18F-FDG PET/CT in a single combined imaging examination. We further examined the potential of such combined examinations by comparing dual tracer 18F-NaF18/F-FDG PET/CT with CT alone for detection of osseous metastasis. Seventy-five participants with biopsy-proven malignancy were consecutively enrolled from a single center and underwent combined 18F-NaF/18F-FDG PET/CT and diagnostic CT scans. PET/CT as well as CT only images were reviewed in blinded fashion and compared with the results of clinical, imaging, or histological follow-up as a truth standard. Sensitivity of the combined 18F-NaF/18F-FDG PET/CT was higher than that of CT alone (97.4% vs 66.7%). CT and 18F-NaF/18F-FDG PET/CT were concordant in 73% of studies. Of 20 discordant cases, 18F-NaF/18F-FDG PET/CT was correct in 19 (95%). Three cases were interpreted concordantly but incorrectly, and all 3 were false positives. A single case of osseous metastasis was detected by CT alone, but not by 18F-NaF/18F-FDG PET/CT. Combined 18F-NaF/18F-FDG PET/CT outperforms CT alone and is highly sensitive and specific for detection of osseous metastases. The concordantly interpreted false-positive cases demonstrate the difficulty of distinguishing degenerative from malignant disease, whereas the single case of metastasis seen on CT but not PET highlights the need for careful review of CT images in multimodality studies.

  3. Fluorine-18 labeling of an anti-HER2 VHH using a residualizing prosthetic group via a strain-promoted click reaction: Chemistry and preliminary evaluation.

    PubMed

    Zhou, Zhengyuan; Chitneni, Satish K; Devoogdt, Nick; Zalutsky, Michael R; Vaidyanathan, Ganesan

    2018-05-01

    In a previous study, we evaluated a HER2-specific single domain antibody fragment (sdAb) 2Rs15d labeled with 18 F via conjugation of a residualizing prosthetic agent that was synthesized by copper-catalyzed azide-alkyne cycloaddition (CuAAC). In order to potentially increase overall efficiency and decrease the time required for labeling, we now investigate the use of a strain-promoted azide-alkyne cycloaddition (SPAAC) between the 2Rs15d sdAb, which had been pre-derivatized with an azide-containing residualizing moiety, and an 18 F-labeled aza-dibenzocyclooctyne derivative. The HER2-targeted sdAb 2Rs15d and a nonspecific sdAb R3B23 were pre-conjugated with a moiety containing both azide- and guanidine functionalities. The thus derivatized sdAbs were radiolabeled with 18 F using an 18 F-labeled aza-dibenzocyclooctyne derivative ([ 18 F]F-ADIBO) via SPAAC, generating the desired conjugate ([ 18 F]RL-II-sdAb). For comparison, unmodified 2Rs15d was labeled with N-succinimidyl 4-guanidinomethyl-3-[ 125 I]iodobenzoate ([ 125 I]SGMIB), the prototypical residualizing agent for radioiodination. Radiochemical purity (RCP), immunoreactive fraction (IRF), HER2-binding affinity and cellular uptake of [ 18 F]RL-II-2Rs15d were assessed in vitro. Paired label biodistribution of [ 18 F]RL-II-2Rs15d and [ 125 I]SGMIB-2Rs15d, and microPET/CT imaging of [ 18 F]RL-II-2Rs15d and the [ 18 F]RL-II-R3B23 control sdAb were performed in nude mice bearing HER2-expressing SKOV-3 xenografts. A radiochemical yield of 23.9 ± 6.9% (n = 8) was achieved for the SPAAC reaction between [ 18 F]F-ADIBO and azide-modified 2Rs15d and the RCP of the labeled sdAb was >95%. The affinity (K d ) and IRF for the binding of [ 18 F]RL-II-2Rs15d to HER2 were 5.6 ± 1.3 nM and 73.1 ± 22.5% (n = 3), respectively. The specific uptake of [ 18 F]RL-II-2Rs15d by HER2-expressing BT474M1 breast carcinoma cells in vitro was 14-17% of the input dose at 1, 2, and 4 h, slightly higher than seen for

  4. No-carrier-added [.sup.18 F]-N-fluoroalkylspiroperidols

    DOEpatents

    Shiue, Chyng-Yann; Wolf, Alfred P.; Bai, Lan-Qin; Teng, Ren-Tui

    1989-01-01

    There is disclosed radioligands labeled with the position emitting radionuclide [.sup.18 F] suitable for dynamic study in living humans with position emission transaxial tomography. These new [.sup.18 F]-N-fluoroalkylspiroperidols, wherein the alkyl group contains from 2-6 carbon atoms, exhibit extremely high affinity for the dopamine receptors and provide enhanced uptake and retention in the brain concomitant with reduced radiation burden. These characteristics all combine to make these new radioligands useful for mapping dopamine receptors in normal and disease states in the living brain. Additionally, a new synthetic procedure for these radioligands as well as a new procedure for preparing the radiolabeled alkyl halide alkylating reagents are also disclosed.

  5. Rapid synthesis of maleimide functionalized fluorine-18 labeled prosthetic group using "radio-fluorination on the Sep-Pak" method.

    PubMed

    Basuli, Falguni; Zhang, Xiang; Jagoda, Elaine M; Choyke, Peter L; Swenson, Rolf E

    2018-06-30

    Following our recently published fluorine-18 labeling method, "Radio-fluorination on the Sep-Pak", we have successfully synthesized 6-[ 18 F]fluoronicotinaldehyde by passing a solution (1:4 acetonitrile: t-butanol) of its quaternary ammonium salt precursor, 6-(N,N,N-trimethylamino)nicotinaldehyde trifluoromethanesulfonate (2), through a fluorine-18 containing anion exchange cartridge (PS-HCO 3 ). Over 80% radiochemical conversion was observed using 10 mg of precursor within 1 minute. The [ 18 F]fluoronicotinaldehyde ([ 18 F]5) was then conjugated with 1-(6-(aminooxy)hexyl)-1H-pyrrole-2,5-dione to prepare the fluorine-18 labeled maleimide functionalized prosthetic group, 6-[ 18 F]fluoronicotinaldehyde O-(6-(2,5-dioxo-2,5-dihydro-1H-pyrrol-1-yl)hexyl) oxime, 6-[ 18 F]FPyMHO ([ 18 F]6). The current Sep-Pak method not only improves the overall radiochemical yield (50 ± 9%, decay-corrected, n = 9) but also significantly reduces the synthesis time (from 60-90 minutes to 30 minutes) when compared with literature methods for the synthesis of similar prosthetic groups. Published 2018. This article is a U.S. Government work and is in the public domain in the USA.

  6. PET imaging of apoptosis in tumor-bearing mice and rabbits after paclitaxel treatment with 18F-Labeled recombinant human His10-annexin V

    PubMed Central

    Qin, Haidong; Zhang, Ming-Rong; Xie, Lin; Hou, Yanjie; Hua, Zichun; Hu, Minjin; Wang, Zizheng; Wang, Feng

    2015-01-01

    Monitoring response to chemo- or radiotherapy is of great importance in clinical practice. Apoptosis imaging serves as a very useful tool for the early evaluation of tumor response. The goal of this study was PET imaging of apoptosis with 18F-labeled recombinant human annexin V linked with 10 histidine tag (18F-rh-His10-annexin V) in nude mice bearing an A549 tumor and rabbits bearing a VX2 lung cancer after paclitaxel therapy. 18F-rh-His10-annexin V was prepared by conjugation of rh-His10-annexin V with N-succinimidyl 4-[18F]fluorobenzoate. Biodistribution was determined in mice by the dissection method and small-animal PET. Single-dose paclitaxel (175 mg/m2) was used to induce apoptosis in A549 and VX2 tumor models. 18F-rh-His10-annexin V was injected into A549 mice and VX rabbits to acquire dynamic and static PET images 72 h after paclitaxel treatment. The uptake of 18F-rh-His10-annexin V in apoptotic cells 4 h after induction was 6.45±0.52 fold higher than that in non-induced cells. High focal uptake of 18F-rh-His10-annexin V was visualized in A549 (SUVmax: 0.35±0.13) and VX2 (0.41±0.23) tumor models after paclitaxel treatment, whereas lower uptake was found in the corresponding tumors before treatment (A549 SUVmax: 0.04±0.02; VX2: 0.009±0.002). The apoptotic index was 75.61±11.56% in the treated VX2 cancer, much higher than that in the untreated VX2 (8.03±2.81%). This study demonstrated the feasibility of 18F-rh-His10-annexin V for the detection of apoptosis after chemotherapy in A549 and VX2 tumor models. PMID:25625024

  7. Synthesis and evaluation of 18F-labeled ATP competitive inhibitors of topoisomerase II as probes for imaging topoisomerase II expression

    PubMed Central

    Daumar, Pierre; Zeglis, Brian M.; Ramos, Nicholas; Divilov, Vadim; Sevak, Kuntal Kumar; Pillarsetty, NagaVaraKishore; Lewis, Jason S.

    2015-01-01

    Type II topoisomerase (Topo-II) is an ATP-dependent enzyme that is essential in the transcription, replication, and chromosome segregation processes and, as such, represents an attractive target for cancer therapy. Numerous studies indicate that the response to treatment with Topo-II inhibitors is highly dependent on both the levels and the activity of the enzyme. Consequently, a non-invasive assay to measure tumoral Topo-II levels has the potential to differentiate responders from non-responders. With the ultimate goal of developing a radiofluorinated tracer for positron emission tomography (PET) imaging, we have designed, synthesized, and evaluated a set of fluorinated compounds based on the structure of the ATP-competitive Topo-II inhibitor QAP1. Compounds 18 and 19b showed inhibition of Topo-II in in vitro assays and exhibited moderate, Topo-II level dependent cytotoxicity in SK-BR-3 and MCF-7 cell lines. Based on these results, 18F-labeled analogs of these two compounds were synthesized and evaluated as PET probes for imaging Topo-II overexpression in mice bearing SK-BR-3 xenografts. [18F]-18 and [18F]-19b were synthesized from their corresponding protected tosylated derivatives by fluorination and subsequent deprotection. Small animal PET imaging studies indicated that both compounds do not accumulate in tumors and exhibit poor pharmacokinetics, clearing from the blood pool very rapidly and getting metabolized over. The insights gained from the current study will surely aid in the design and construction of future generations of PET agents for the non-invasive delineation of Topo-II expression. PMID:25240701

  8. Synthesis, Bioconjugation and Stability Studies of [18 F] Ethenesulfonyl Fluoride.

    PubMed

    Zhang, Bo; Pascali, Giancarlo; Wyatt, Naomi; Matesic, Lidia; Klenner, Mitchell A; Sia, Tiffany R; Guastella, Adam J; Massi, Massimiliano; Robinson, Andrea J; Fraser, Benjamin H

    2018-06-20

    Fluorine-18 labelled prosthetic groups (PGs) are often necessary for radiolabelling sensitive biological molecules such as peptides and proteins. Several shortcomings, however, often diminish the final yield of radiotracer. In an attempt to provide higher yielding and operationally efficient tools for radiolabelling biological molecules, we describe herein the first radiochemical synthesis of [ 18 F] ethenesulfonylfluoride ([ 18 F] ESF) and its Michael conjugation with amino acids and proteins. The synthesis of [ 18 F] ESF was optimised using a microfluidic reactor under both carrier-added (c.a.) and no-carrier-added (n.c.a.) conditions, affording, in a straightforward procedure, 30-50% radiochemical yield (RCY) for c.a. [ 18 F] ESF and 60-70% RCY for n.c.a. [ 18 F] ESF. The conjugation reactions were performed at room temperature using 10 mg/mL precursor in aqueous/organic solvent mixtures for 15 min. The radiochemical stability of the final conjugates was evaluated in injectable formulation and rat serum, and resulted strongly substrate dependent and generally poor in rat serum. Therefore, in this work we have optimised a straightforward synthesis of [ 18 F] ESF and its Michael conjugation with model compounds, without requiring chromatographic purification. However, given the general low stability of the final products, further studies will be required for improving conjugate stability, before assessing the use of this PG for PET imaging. This article is protected by copyright. All rights reserved.

  9. The feasibility of 18F-AlF-NOTA-PRGD2 PET/CT for monitoring early response of Endostar antiangiogenic therapy in human nasopharyngeal carcinoma xenograft model compared with 18F-FDG

    PubMed Central

    Liang, Sheng; Zhang, Caiyuan; Cheng, Weiwei; Hai, Wangxi; Yin, Bing; Wang, Dengbin

    2016-01-01

    Purpose Radiolabeled arginine-glycine-aspartic acid (RGD) peptides have been developed for PET imaging of integrin avβ3 in the tumor vasculature, leading to great potential for noninvasively evaluating tumor angiogenesis and monitoring antiangiogenic treatment. The aim of this study was to investigate a novel one-step labeled integrin-targeted tracer, 18F-AlF-NOTA-PRGD2, for PET/CT for detecting tumor angiogenesis and monitoring the early therapeutic efficacy of antiangiogenic agent Endostar in human nasopharyngeal carcinoma (NPC) xenograft model. Experimental design and results Mice bearing NPC underwent 18F-AlF-NOTA-PRGD2 PET/CT at baseline and after 2, 4, 7, and 14 days of consecutive treatment with Endostar or PBS, compared with 18F-FDG PET/CT. Tumors were harvested at all imaging time points for histopathological analysis with H & E and microvessel density (MVD) and integrin avβ3 immunostaining. The maximum percent injected dose per gram of body weight (%ID/gmax) tumor uptake of 18F-AlF-NOTA-PRGD2 PET/CT was significantly lower than that in the control group starting from day 2 (p < 0.01), much earlier and more accurately than that of 18F-FDG PET/CT. Moreover, a moderate linear correlation was observed between tumor MVD and the corresponding tumor uptake of 18F-AlF-NOTA-PRGD2 PET/CT (r = 0.853, p < 0.01). Conclusions 18F-AlF-NOTA-PRGD2 PET/CT can be used for in vivo angiogenesis imaging and monitoring early response to Endostar antiangiogenic treatment in NPC xenograft model, favoring its potential clinical translation. PMID:27029065

  10. Preclinical evaluation of an 18F-labelled beta1-adrenoceptor selective radioligand based on ICI 89,406.

    PubMed

    Law, Marilyn P; Wagner, Stefan; Kopka, Klaus; Renner, Christiane; Pike, Victor W; Schober, Otmar; Schäfers, Michael

    2010-05-01

    Radioligand binding studies indicate a down-regulation of myocardial beta(1)-adrenoceptors (beta(1)-AR) in cardiac disease which may or may not be associated with a decrease in beta(2)-ARs. We have chosen ICI 89,406, a beta(1)-selective AR antagonist, as the lead structure to develop new beta(1)-AR radioligands for PET and have synthesised a fluoro-ethoxy derivative (F-ICI). (S)-N-[2-[3-(2-Cyano-phenoxy)-2-hydroxy-propylamino]-ethyl]-N'-[4-(2-[(18)F]fluoro-ethoxy)-phenyl]-urea ((S)-[(18)F]F-ICI) was synthesised. Myocardial uptake of radioactivity after intravenous injection of (S)-[(18)F]F-ICI into adult CD(1) mice or Wistar rats was assessed with positron emission tomography (PET) and postmortem dissection. Metabolism was assessed by high-performance liquid chromatography analysis of plasma and urine. The heart was visualised with PET after injection of (S)-[(18)F]F-ICI but neither unlabelled F-ICI nor propranolol (non-selective beta-AR antagonist) injected 15 min after (S)-[(18)F]F-ICI affected myocardial radioactivity. Ex vivo dissection demonstrated that predosing with propranolol or CGP 20712 (beta(1)-selective AR-antagonist) did not affect myocardial radioactivity. Radiometabolites rapidly appeared in plasma and both (S)-[(18)F]F-ICI and radiometabolites accumulated in urine. Myocardial uptake of (S)-[(18)F]F-ICI after intravenous injection was mainly at sites unrelated to beta(1)-ARs. (S)-[(18)F]F-ICI is not a suitable beta(1)-selective-AR radioligand for PET. (c) 2010 Elsevier Inc. All rights reserved.

  11. Preclinical evaluation of an 18F-labelled β1-adrenoceptor selective radioligand based on ICI 89,406

    PubMed Central

    Law, Marilyn P.; Wagner, Stefan; Kopka, Klaus; Renner, Christiane; Pike, Victor W.; Schober, Otmar; Schäfers, Michael

    2010-01-01

    Purpose Radioligand binding studies indicate a down-regulation of myocardial β1-adrenoceptors (β1-AR) in cardiac disease which may or may not be associated with a decrease in β2-ARs. We have chosen ICI 89,406, a β1-selective AR antagonist, as the lead structure to develop new β1-AR radioligands for PET and have synthesised a fluoro-ethoxy derivative (F-ICI). Methods (S)-N-[2-[3-(2-Cyano-phenoxy)-2-hydroxy-propylamino]-ethyl]-N′-[4-(2-[18F]fluoro-ethoxy)-phenyl]-urea ((S)-[18F]F-ICI) was synthesised. Myocardial uptake of radioactivity after intravenous injection of (S)-[18F]F-ICI into adult CD1 mice or Wistar rats was assessed with positron emission tomography (PET) and postmortem dissection. Metabolism was assessed by high-performance liquid chromatography analysis of plasma and urine. Results The heart was visualised with PET after injection of (S)-[18F]F-ICI but neither unlabelled F-ICI nor propranolol (non-selective β-AR antagonist) injected 15 min after (S)-[18F]F-ICI affected myocardial radioactivity. Ex vivo dissection demonstrated that predosing with propranolol or CGP 20712 (β1-selective AR-antagonist) did not affect myocardial radioactivity. Radiometabolites rapidly appeared in plasma and both (S)-[18F]F-ICI and radiometabolites accumulated in urine. Conclusions Myocardial uptake of (S)-[18F]F-ICI after intravenous injection was mainly at sites unrelated to β1-ARs. (S)-[18F]F-ICI is not a suitable β1-selective-AR radioligand for PET. PMID:20447564

  12. Biodistribution and Stability Studies of [18F]Fluoroethylrhodamine B, a Potential PET Myocardial Perfusion Agent

    PubMed Central

    Gottumukkala, Vijay; Heinrich, Tobias K.; Baker, Amanda; Dunning, Patricia; Fahey, Frederick H; Treves, S. Ted; Packard, Alan B.

    2010-01-01

    Introduction Fluorine-18-labeled rhodamine B was developed as a potential PET tracer for the evaluation of myocardial perfusion, but preliminary studies in mice showed no accumulation in the heart suggesting that it was rapidly hydrolyzed in vivo in mice. A study was, therefore, undertaken to further evaluate this hypothesis. Methods [18F]Fluoroethylrhodamine B was equilibrated for 2 h at 37 °C in human, rat and mouse serum and in PBS. Samples were removed periodically and assayed by HPLC. Based on the results of the stability study, microPET imaging and a biodistribution study were carried out in rats. Results In vitro stability studies demonstrated that [18F]fluoroethylrhodamine B much more stable in rat and human sera than in mouse serum. After 2 h, the compound was >80% intact in rat serum but <30% intact in mouse serum. The microPET imaging and biodistribution studies in rats confirmed this result showing high and persistent tracer accumulation in the myocardium compared with the absence of uptake by the myocardium in mice thereby validating our original hypothesis that 18F-labeled rhodamines should accumulate in the heart. Conclusions [18F]Fluoroethyl rhodamine B is more stable in rat and human sera than it is in mouse serum. This improved stability is demonstrated by the high uptake of the tracer in the rat heart in comparison to the absence of visible uptake in the mouse heart. These observations suggest that 18F-labeled rhodamines are promising candidates for more extensive evaluation as PET tracers for the evaluation of myocardial perfusion. PMID:20346876

  13. Optimizing a 18F-NaF and 18F-FDG cocktail for PET assessment of metastatic castration-resistant prostate cancer

    PubMed Central

    Simoncic, Urban; Perlman, Scott; Liu, Glenn; Jeraj, Robert

    2015-01-01

    Background The 18F-NaF/18F-FDG cocktail PET/CT imaging has been proposed for patients with osseous metastases. This work aimed to optimize the cocktail composition for patients with metastatic castrate-resistant prostate cancer (mCRPC). Materials and methods Study was done on 6 patients with mCRPC that had analyzed a total of 26 lesions. Patients had 18F-NaF and 18F-FDG injections separated in time. Dynamic PET/CT imaging recorded uptake time course for both tracers into osseous metastases. 18F-NaF and 18F-FDG uptakes were decoupled by kinetic analysis, which enabled calculation of 18F-NaF and 18F-FDG Standardized Uptake Value (SUV) images. Peak, mean and total SUVs were evaluated for both tracers and all visible lesions. The 18F-NaF/18F-FDG cocktail was optimized under the assumption that contribution of both tracers to the image formation should be equal. SUV images for combined 18F-NaF/18F-FDG cocktail PET/CT imaging were generated for cocktail compositions with 18F-NaF:18F-FDG ratio varying from 1:8 to 1:2. Results The 18F-NaF peak and mean SUVs were on average 4-5 times higher than the 18F-FDG peak and mean SUVs, with inter-lesion coefficient-of-variations (COV) of 20%. 18F-NaF total SUV was on average 7 times higher than the 18F-FDG total SUV. When the 18F-NaF:18F-FDG ratio changed from 1:8 to 1:2, typical SUV on generated PET images increased by 50%, while change in uptake visual pattern was hardly noticeable. Conclusion The 18F-NaF/18F-FDG cocktail has equal contributions of both tracers to the image formation when the 18F-NaF:18F-FDG ratio is 1:5. Therefore we propose this ratio as the optimal cocktail composition for mCRPC patients. We also urge to strictly control the 18F-NaF/18F-FDG cocktail composition in any 18F-NaF/18F-FDG cocktail PET/CT exams. PMID:26378490

  14. Biodistribution, pharmacokinetics and PET imaging of [(18)F]FMISO, [(18)F]FDG and [(18)F]FAc in a sarcoma- and inflammation-bearing mouse model.

    PubMed

    Liu, Ren-Shyan; Chou, Ta-Kai; Chang, Chih-Hsien; Wu, Chun-Yi; Chang, Chi-Wei; Chang, Tsui-Jung; Wang, Shih-Jen; Lin, Wuu-Jyh; Wang, Hsin-Ell

    2009-04-01

    2-Deoxy-2-[(18)F]fluoro-d-glucose ([(18)F]FDG), [(18)F]fluoroacetate ([(18)F]FAc) and [(18)F]fluoromisonidazole ([(18)F]FMISO) were all considered to be positron emission tomography (PET) probes for tumor diagnosis, though based on different rationale of tissue uptake. This study compared the biodistribution, pharmacokinetics and imaging of these three tracers in a sarcoma- and inflammation-bearing mouse model. C3H mice were inoculated with 2x10(5) KHT sarcoma cells in the right thigh on Day 0. Turpentine oil (0.1 ml) was injected in the left thigh on Day 11 to induce inflammatory lesion. Biodistribution, pharmacokinetics and microPET imaging of [(18)F]FMISO, [(18)F]FDG and [(18)F]FAc were performed on Day 14 after tumor inoculation. The inflammatory lesions were clearly visualized by [(18)F]FDG/microPET and autoradiography at 3 days after turpentine oil injection. The tumor-to-muscle and inflammatory lesion-to-muscle ratios derived from microPET imaging were 6.79 and 1.48 for [(18)F]FMISO, 8.12 and 4.69 for [(18)F]FDG and 3.72 and 3.19 for [(18)F]FAc at 4 h post injection, respectively. Among these, the tumor-to-inflammation ratio was the highest (4.57) for [(18)F]FMISO compared with that of [(18)F]FDG (1.73) and [(18)F]FAc (1.17), whereas [(18)F]FAc has the highest bioavailability (area under concentration of radiotracer vs. time curve, 116.2 hxpercentage of injected dose per gram of tissue). MicroPET images and biodistribution studies showed that the accumulation of [(18)F]FMISO in the tumor is significantly higher than that in inflammatory lesion at 4 h post injection. [(18)F]FDG and [(18)F]FAc delineated both tumor and inflammatory lesions. Our results demonstrated the potential of [(18)F]FMISO/PET in distinguishing tumor from inflammatory lesion.

  15. Whole-body biodistribution and radiation dosimetry of 18F-FP-(+)-DTBZ (18F-AV-133): a novel vesicular monoamine transporter 2 imaging agent.

    PubMed

    Lin, Kun-Ju; Weng, Yi-Hsin; Wey, Shiaw-Pyng; Hsiao, Ing-Tsung; Lu, Chin-Song; Skovronsky, Daniel; Chang, Hsiu-Ping; Kung, Mei-Ping; Yen, Tzu-Chen

    2010-09-01

    Vesicular monoamine transporter 2 (VMAT2) is highly expressed in the endocrine cells and brain. We investigated the biodistribution and radiation dosimetry of (2R,3R,11bR)-9-(3-(18)F-fluoropropoxy)-3-isobutyl-10-methoxy-2,3,4,6,7,11b-hexahydro-1H-pyrido[2,1-a]isoquinolin-2-ol ((18)F-FP-(+)-dihydrotetrabenazine [DTBZ] or (18)F-AV-133), a potential VMAT2 imaging agent showing encouraging results in humans, to facilitate its future clinical use. Nine healthy human subjects (mean age +/- SD, 58.6 +/- 4.2 y) were enrolled for the whole-body PET scan. Serial images were acquired for 3 h immediately after a bolus injection of 390.7 +/- 22.9 MBq of (18)F-AV-133 per individual. The source organs were delineated on PET/CT images. The OLINDA/EXM application was used to determine the equivalent dose for individual organs. The radiotracer did not show any noticeable adverse effects for the 9 subjects examined. The radioactivity uptake in the brain was the highest at 7.5% +/- 0.6% injected dose at 10 min after injection. High absorbed doses were found in the pancreas, liver, and upper large intestine wall. The highest-dosed organ, which received 153.3 +/- 23.8 microGy/MBq, was the pancreas. The effective dose equivalent and effective dose for (18)F-AV-133 were 36.5 +/- 2.8 and 27.8 +/- 2.5 microSv/MBq, respectively. These values are comparable to those reported for any other (18)F-labeled radiopharmaceutical. (18)F-AV-133 is safe, with appropriate biodistribution and radiation dosimetry for imaging VMAT2 sites in humans.

  16. One-pot synthesis and biodistribution of fluorine-18 labeled serum albumin for vascular imaging.

    PubMed

    Basuli, Falguni; Zhang, Xiang; Williams, Mark R; Seidel, Jurgen; Green, Michael V; Choyke, Peter L; Swenson, Rolf E; Jagoda, Elaine M

    2018-05-30

    Equilibrium single-photon radionuclide imaging methods for assessing cardiac function and the integrity of the vascular system have long been in use for both clinical and research purposes. However, positron-emitting blood pool agents that could provide PET equivalents to these (and other) clinical procedures have not yet been adopted despite technical imaging advantages offered by PET. Our goal was to develop a PET blood pool tracer that not only meets necessary in vivo biological requirements but can be produced with an uncomplicated and rapid synthesis method which would facilitate clinical translation. Herein, albumin labeled with fluorine-18 was synthesized using a one-pot method and evaluated in vitro and in vivo in rats. A ligand (NODA-Bz-TFPE), containing NODA attached to a tetrafluorophenylester (TFPE) via a phenyl linker (Bz), was labeled with aluminum fluoride (Al[ 18 F]F). Conjugation of the serum albumin with the ligand (Al[ 18 F]F-NODA-Bz-TFPE), followed by purification (size exclusion chromatography), yielded the final product (Al[ 18 F]F-NODA-Bz-RSA/HSA). In vitro stability was evaluated in human serum albumin by HPLC. Rat biodistributions and whole-body PET imaging over a 4 h time course were used for the in vivo evaluation. This synthesis exhibited an overall radiochemical yield of 45 ± 10% (n = 30), a 50-min radiolabeling time, a radiochemical purity >99% and apparent stability up to 4 h in human serum. Blood had the highest retention of Al[ 18 F]F-NODA-Bz-RSA at all times with a blood half-life of 5.2 h in rats. Al[ 18 F]F-NODA-Bz-RSA distribution in most rat tissues remained relatively constant for up to 1 h, indicating that the tissue radioactivity content represents the respective tissue plasma volume. Dynamic whole-body PET images were in agreement with these findings. A new ligand has been developed and radiolabeled with Al[ 18 F]F that allows rapid (50-min) preparation of fluorine-18 serum albumin in one-pot. In addition

  17. Radiosynthesis and biological evaluation of N-(2-[18F]fluoropropionyl)-3,4-dihydroxy-l-phenylalanine as a PET tracer for oncologic imaging.

    PubMed

    Tang, Caihua; Nie, Dahong; Tang, Ganghua; Gao, Siyuan; Liu, Shaoyu; Wen, Fuhua; Tang, Xiaolan

    2017-07-01

    Several 11 C and 18 F labeled 3,4-dihydroxy-l-phenylalanine (l-DOPA) analogues have been used for neurologic and oncologic diseases, especially for brain tumors and neuroendocrine tumors PET imaging. However, 18 F-labeled N-substituted l-DOPA analogues have not been reported so far. In the current study, radiosynthesis and biological evaluation of a new 18 F-labeled l-DOPA analogue, N-(2-[ 18 F]fluoropropionyl)-3,4-dihydroxy-l-phenylalanine ([ 18 F]FPDOPA) for tumor PET imaging are performed. The synthesis of [ 18 F]FPDOPA was via a two-step reaction sequence from 4-nitrophenyl-2-[ 18 F]fluoropropionate ([ 18 F]NFP). The biodistribution of [ 18 F]FPDOPA was determined in normal Kunming mice. In vitro competitive inhibition and protein incorporation experiments were performed with SPC-A-1 lung adenocarcinoma cell lines. PET/CT studies of [ 18 F]FPDOPA were conducted in C6 rat glioma and SPC-A-1 human lung adenocarcinoma and H460 human large cell lung cancer-bearing nude mice. [ 18 F]FPDOPA was prepared with a decay-corrected radiochemical yield of 28±5% and a specific activity of 50±15GBq/μmol (n=10) within 125min. In vitro cell experiments showed that [ 18 F]FPDOPA uptake in SPC-A-1 cells was primarily transported through Na + -independent system L, with Na + -dependent system B 0,+ and system ASC partly involved in it. Biodistribution data in mice showed that renal-bladder route was the main excretory system of [ 18 F]FPDOPA. PET imaging demonstrated intense accumulation of [ 18 F]FPDOPA in several tumor xenografts, with (8.50±0.40)%ID/g in C6 glioma, (6.30±0.12)%ID/g in SPC-A-1 lung adenocarcinoma, and (6.50±0.10)%ID/g in H460 large cell lung cancer, respectively. A novel N-substituted 18 F-labeled L-DOPA analogue [ 18 F]FPDOPA is synthesized and evaluated in vitro and in vivo. The results support that [ 18 F]FPDOPA seems to be a potential PET tracer for tumor imaging, especially be a better potential PET tracer than [ 18 F]fluoro-2-deoxy-d-glucose ([ 18 F

  18. Clinical utility of (18)F-fluoride PET/CT in benign and malignant bone diseases.

    PubMed

    Li, Yuxin; Schiepers, Christiaan; Lake, Ralph; Dadparvar, Simin; Berenji, Gholam R

    2012-01-01

    (18)F labeled sodium fluoride is a positron-emitting, bone seeking agent with more favorable skeletal kinetics than conventional phosphate and diphosphonate compounds. With the expanding clinical usage of PET/CT, there is renewed interest in using (18)F-fluoride PET/CT for imaging bone diseases. Growing evidence indicates that (18)F fluoride PET/CT offers increased sensitivity, specificity, and diagnostic accuracy in evaluating metastatic bone disease compared to (99m)Tc based bone scintigraphy. National Oncologic PET Registry (NOPR) has expanded coverage for (18)F sodium fluoride PET scans since February 2011 for the evaluation of osseous metastatic disease. In this article, we reviewed the pharmacological characteristics of sodium fluoride, as well as the clinical utility of PET/CT using (18)F-fluoride in both benign and malignant bone disorders. Published by Elsevier Inc.

  19. Facile radiosynthesis of fluorine-18 labeled beta-blockers. Synthesis, radiolabeling, and ex vivo biodistribution of [18F]-(2S and 2R)-1-(1-fluoropropan-2-ylamino)-3-(m-tolyloxy)propan-2-ol.

    PubMed

    Stephenson, Karin A; Wilson, Alan A; Meyer, Jeffrey H; Houle, Sylvain; Vasdev, Neil

    2008-08-28

    An efficient and general method has been developed for fluorine-18 labeling of beta-blockers that possess the propanolamine moiety. A new synthetically versatile intermediate, 3-(1-(benzyloxy)propan-2-yl)-2-oxooxazolidin-5-yl)methyl 4-methylbenzenesulfonate (13), was prepared and can be conjugated to any phenoxy core. To demonstrate the synthetic methodology, fluorinated derivatives of toliprolol were prepared, namely, [(18)F]-(2S and 2R)-1-(1-fluoropropan-2-ylamino)-3-(m-tolyloxy)propan-2-ol ((2S and 2R)-[(18)F]1). The radiosyntheses were accomplished in <1 h, with 20-24% (uncorrected for decay, n = 7) radiochemical yields, >96% radiochemical and >99% enantiomeric purities, with specific activities of 0.9-1.1 Ci/micromol (EOS). Ex vivo biodistribution studies with the radiotracers demonstrated excessively rapid washout that may limit their use for cerebral PET imaging.

  20. Dual acquisition of 18F-FMISO and 18F-FDOPA

    NASA Astrophysics Data System (ADS)

    Bell, Christopher; Rose, Stephen; Puttick, Simon; Pagnozzi, Alex; Poole, Christopher M.; Gal, Yaniv; Thomas, Paul; Fay, Michael; Jeffree, Rosalind L.; Dowson, Nicholas

    2014-07-01

    Metabolic imaging using positron emission tomography (PET) has found increasing clinical use for the management of infiltrating tumours such as glioma. However, the heterogeneous biological nature of tumours and intrinsic treatment resistance in some regions means that knowledge of multiple biological factors is needed for effective treatment planning. For example, the use of 18F-FDOPA to identify infiltrative tumour and 18F-FMISO for localizing hypoxic regions. Performing multiple PET acquisitions is impractical in many clinical settings, but previous studies suggest multiplexed PET imaging could be viable. The fidelity of the two signals is affected by the injection interval, scan timing and injected dose. The contribution of this work is to propose a framework to explicitly trade-off signal fidelity with logistical constraints when designing the imaging protocol. The particular case of estimating 18F-FMISO from a single frame prior to injection of 18F-FDOPA is considered. Theoretical experiments using simulations for typical biological scenarios in humans demonstrate that results comparable to a pair of single-tracer acquisitions can be obtained provided protocol timings are carefully selected. These results were validated using a pre-clinical data set that was synthetically multiplexed. The results indicate that the dual acquisition of 18F-FMISO and 18F-FDOPA could be feasible in the clinical setting. The proposed framework could also be used to design protocols for other tracers.

  1. No-carrier-added (/sup 18/F)-N-methylspiroperidol

    DOEpatents

    Shiue, C.Y.; Fowler, J.S.; Wolf, A.P.

    1985-10-04

    The present invention is directed to the synthesis of a radioligand, labeled with a positron emitting radionuclide which is suitable for dynamic studies in humans using positron emission transaxial tomography. No-carrier-added (NCA) (/sup 18/F)-N-methylspiroperiodl is prepared from four different sustrates: p-nitrobenzonitrile, cyclopropyl p-nitrophenyl ketone, p-cyclopropanoyl-N,N,N-trimethylanilinium iodide and p-cyclopropanoyl-N,N,N-trimethylanilinium perchlorate. The process for the production of NCA (/sup 18/F)-N-methylspiroperidol is a nucleophilic aromatic substitution reaction. Furthermore, the compound of this invention is shown to be effective as a new drug of choice for in vivo examination of dopamine binding sites in a human brain. In particular, this drug is primarily useful in the noninvasive technique of positron emission transaxial tomography (PETT).

  2. In vivo evaluation of 18F-MNI698: an 18F-labeled radiotracer for imaging of serotonin 4 receptors in brain.

    PubMed

    Tavares, Adriana Alexandre S; Caillé, Fabien; Barret, Olivier; Papin, Caroline; Lee, Hsiaoju; Morley, Thomas J; Fowles, Krista; Holden, Daniel; Seibyl, John P; Alagille, David; Tamagnan, Gilles D

    2014-05-01

    Serotonin 4 receptors (5-hydroxytryptamine receptor 4 [5HT4R]) hold promise as a novel therapeutic approach to multiple brain disorders, including Alzheimer and Huntington disease. In vivo imaging of these receptors with selective 5HT4R radiotracers and PET would be valuable to investigate alterations in 5HT4R in different brain disorders and to assist drug discovery. In this study, (18)F-MNI698 was evaluated as a potential PET radiotracer for imaging of 5HT4R in the brain. Eighteen PET studies were performed in 3 adult rhesus monkeys. The radiotracer was administered as a bolus intravenous injection or bolus plus constant infusion (time that would be required to inject the bolus at the infusion rate = 60 min), and arterial blood was collected for data quantification. Kinetic models were used to estimate distribution volumes and binding potentials, for which the cerebellum was used as a reference region. (18)F-MNI698 test-retest variability and upper mass dose limits were determined. Preblocking studies using several doses of SB204070, a selective 5HT4R antagonist, were performed. (18)F-MNI698 avidly entered the monkey brain (peak percentage injected dose of ∼ 6.6%), and its brain distribution was consistent with known 5HT4R densities. At 120 min after bolus injection and after the start of radiotracer infusion, only less than 5% and approximately 10% parent compound was present in blood, respectively. Measured binding potentials were underestimated by 22%-36% when noninvasive methods were used for data quantification in comparison with invasive methods. A good agreement was found between test-retest measurements. The radiotracer upper mass dose limit (<5% occupancy) was determined to be 13.1 μg per 70 kg of body weight. SB204070 blocked the radiotracer binding in a dose-dependent manner. Data indicate that (18)F-MNI698 is a promising PET radiotracer for imaging of 5HT4R in the brain, and human studies are warranted based on these study results.

  3. Synthesis, radiolabeling, and biological evaluation of ( R)- and ( S)-2-amino-5-[ 18F]fluoro-2-methylpentanoic acid (( R)-, ( S)-[ 18F]FAMPe) as potential positron emission tomography tracers for brain tumors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bouhlel, Ahlem; Zhou, Dong; Li, Aixiao

    In this paper, a novel 18F-labeled α,α-disubstituted amino acid-based tracer, 2-amino-5-[ 18F]fluoro-2-methylpentanoic acid ([ 18F]FAMPe), has been developed for brain tumor imaging with a longer alkyl side chain than previously reported compounds to increase brain availability via system L amino acid transport. Both enantiomers of [ 18F]FAMPe were obtained in good radiochemical yield (24–52% n = 8) and high radiochemical purity (>99%). In vitro uptake assays in mouse DBT gliomas cells revealed that ( S)-[ 18F]FAMPe enters cells partly via sodium-independent system L transporters and also via other nonsystem A transport systems including transporters that recognize glutamine. Biodistribution and smallmore » animal PET/CT studies in the mouse DBT model of glioblastoma showed that both ( R)- and ( S)-[ 18F]FAMPe have good tumor imaging properties with the ( S)-enantiomer providing higher tumor uptake and tumor to brain ratios. Finally, comparison of the SUVs showed that ( S)-[ 18F]FAMPe had higher tumor to brain ratios compared to ( S)-[ 18F]FET, a well-established system L substrate.« less

  4. Synthesis, radiolabeling, and biological evaluation of ( R)- and ( S)-2-amino-5-[ 18F]fluoro-2-methylpentanoic acid (( R)-, ( S)-[ 18F]FAMPe) as potential positron emission tomography tracers for brain tumors

    DOE PAGES

    Bouhlel, Ahlem; Zhou, Dong; Li, Aixiao; ...

    2015-04-06

    In this paper, a novel 18F-labeled α,α-disubstituted amino acid-based tracer, 2-amino-5-[ 18F]fluoro-2-methylpentanoic acid ([ 18F]FAMPe), has been developed for brain tumor imaging with a longer alkyl side chain than previously reported compounds to increase brain availability via system L amino acid transport. Both enantiomers of [ 18F]FAMPe were obtained in good radiochemical yield (24–52% n = 8) and high radiochemical purity (>99%). In vitro uptake assays in mouse DBT gliomas cells revealed that ( S)-[ 18F]FAMPe enters cells partly via sodium-independent system L transporters and also via other nonsystem A transport systems including transporters that recognize glutamine. Biodistribution and smallmore » animal PET/CT studies in the mouse DBT model of glioblastoma showed that both ( R)- and ( S)-[ 18F]FAMPe have good tumor imaging properties with the ( S)-enantiomer providing higher tumor uptake and tumor to brain ratios. Finally, comparison of the SUVs showed that ( S)-[ 18F]FAMPe had higher tumor to brain ratios compared to ( S)-[ 18F]FET, a well-established system L substrate.« less

  5. Synthesis of fluorine-18 radio-labeled serum albumins for PET blood pool imaging.

    PubMed

    Basuli, Falguni; Li, Changhui; Xu, Biying; Williams, Mark; Wong, Karen; Coble, Vincent L; Vasalatiy, Olga; Seidel, Jurgen; Green, Michael V; Griffiths, Gary L; Choyke, Peter L; Jagoda, Elaine M

    2015-03-01

    We sought to develop a practical, reproducible and clinically translatable method of radiolabeling serum albumins with fluorine-18 for use as a PET blood pool imaging agent in animals and man. Fluorine-18 radiolabeled fluoronicotinic acid-2,3,5,6-tetrafluorophenyl ester, [(18)F]F-Py-TFP was prepared first by the reaction of its quaternary ammonium triflate precursor with [(18)F]tetrabutylammonium fluoride ([(18)F]TBAF) according to a previously published method for peptides, with minor modifications. The incubation of [(18)F]F-Py-TFP with rat serum albumin (RSA) in phosphate buffer (pH9) for 15 min at 37-40 °C produced fluorine-18-radiolabeled RSA and the product was purified using a mini-PD MiniTrap G-25 column. The overall radiochemical yield of the reaction was 18-35% (n=30, uncorrected) in a 90-min synthesis. This procedure, repeated with human serum albumin (HSA), yielded similar results. Fluorine-18-radiolabeled RSA demonstrated prolonged blood retention (biological half-life of 4.8 hours) in healthy awake rats. The distribution of major organ radioactivity remained relatively unchanged during the 4 hour observation periods either by direct tissue counting or by dynamic PET whole-body imaging except for a gradual accumulation of labeled metabolic products in the bladder. This manual method for synthesizing radiolabeled serum albumins uses fluorine-18, a widely available PET radionuclide, and natural protein available in both pure and recombinant forms which could be scaled up for widespread clinical applications. These preclinical biodistribution and PET imaging results indicate that [(18)F]RSA is an effective blood pool imaging agent in rats and might, as [(18)F]HSA, prove similarly useful as a clinical imaging agent. Published by Elsevier Inc.

  6. Imaging proliferation in brain tumors with 18F-FLT PET: comparison with 18F-FDG.

    PubMed

    Chen, Wei; Cloughesy, Timothy; Kamdar, Nirav; Satyamurthy, Nagichettiar; Bergsneider, Marvin; Liau, Linda; Mischel, Paul; Czernin, Johannes; Phelps, Michael E; Silverman, Daniel H S

    2005-06-01

    3'-Deoxy-3'-(18)F-fluorothymidine ((18)F-FLT) is a recently developed PET tracer to image tumor cell proliferation. We characterized (18)F-FLT PET of brain gliomas and compared (18)F-FLT with (18)F-FDG PET in side-by-side studies of the same patients. Twenty-five patients with newly diagnosed or previously treated glioma underwent PET with (18)F-FLT and (18)F-FDG on consecutive days. Three stable patients in long-term remission were included as negative control subjects. Tracer kinetics in normal brain and tumor were measured. Uptake of (18)F-FLT and (18)F-FDG was quantified by the standardized uptake value (SUV) and the tumor-to-normal tissue (T/N) ratio. The accuracy of (18)F-FLT and (18)F-FDG PET in evaluating newly diagnosed and recurrent gliomas was compared. More than half of the patients underwent resection after the PET study and correlations between PET uptake and the Ki-67 proliferation index were examined. Patients were monitored for a mean of 15.4 mo (range, 12-20 mo). The predictive power of PET for tumor progression and survival was analyzed using Kaplan-Meier statistics. (18)F-FLT uptake in tumors was rapid, peaking at 5-10 min after injection and remaining stable up to 75 min. Hence, a 30-min scan beginning at 5 min after injection was sufficient for imaging. (18)F-FLT visualized all high-grade (grade III or IV) tumors. Grade II tumor did not show appreciable (18)F-FLT uptake and neither did the stable lesions. The absolute uptake of (18)F-FLT was low (maximum-pixel SUV [SUV(max)], 1.33) but image contrast was better than with (18)F-FDG (T/N ratio, 3.85 vs. 1.49). (18)F-FDG PET studies were negative in 5 patients with recurrent high-grade glioma who subsequently suffered tumor progression within 1-3 mo. (18)F-FLT SUV(max) correlated more strongly with Ki-67 index (r = 0.84; P < 0.0001) than (18)F-FDG SUV(max) (r = 0.51; P = 0.07). (18)F-FLT uptake also had more significant predictive power with respect to tumor progression and survival (P = 0

  7. Synthesis and characterization of boron fenbufen and its F-18 labeled homolog for boron neutron capture therapy of COX-2 overexpressed cholangiocarcinoma.

    PubMed

    Yeh, Chun-Nan; Chang, Chi-Wei; Chung, Yi-Hsiu; Tien, Shi-Wei; Chen, Yong-Ren; Chen, Tsung-Wen; Huang, Ying-Cheng; Wang, Hsin-Ell; Chou, You-Cheng; Chen, Ming-Huang; Chiang, Kun-Chun; Huang, Wen-Sheng; Yu, Chung-Shan

    2017-09-30

    Boron neutron capture therapy (BNCT) is a binary therapy that employs neutron irradiation on the boron agents to release high-energy helium and alpha particles to kill cancer cells. An optimal response to BNCT depends critically on the time point of maximal 10 B accumulation and highest tumor to normal ratio (T/N) for performing the neutron irradiation. The aggressive cholangiocarcinoma (CCA) representing a liver cancer that overexpresses COX-2 enzyme is aimed to be targeted by COX-2 selective boron carrier, fenbufen boronopinacol (FBPin). Two main works were performed including: 1) chemical synthesis of FBPin as the boron carrier and 2) radiochemical labeling with F-18 to provide the radiofluoro congener, m-[ 18 F]fluorofenbufen ester boronopinacol (m-[ 18 F]FFBPin), to assess the binding affinity, cellular accumulation level and distribution profile in CCA rats. FBPin was prepared from bromofenbufen via 3 steps with 82% yield. The binding assay employed [ 18 F]FFBPin to compete FBPin for binding to COX-1 (IC 50 =0.91±0.68μM) and COX-2 (IC 50 =0.33±0.24μM). [ 18 F]FFBPin-derived 60-min dynamic PET scans predict the 10 B-accumulation of 0.8-1.2ppm in liver and 1.2-1.8ppm in tumor and tumor to normal ratio=1.38±0.12. BNCT was performed 40-55min post intravenous administration of FBPin (20-30mg) in the CCA rats. CCA rats treated with BNCT display more tumor reduction than that by NCT with respect of 2-[ 18 F]fluoro-2-deoxy glucose uptake in the tumor region of interest, 20.83±3.00% (n=12) vs. 12.83±3.79% (n=10), P=0.05. The visualizing agent [ 18 F]FFBPin resembles FBPin to generate the time-dependent boron concentration profile. Optimal neutron irradiation period is thus determinable for BNCT. A boron-substituted agent based on COX-2-binding features has been prepared. The moderate COX-2/COX-1 selectivity index of 2.78 allows a fair tumor selectivity index of 1.38 with a mild cardiovascular effect. The therapeutic effect from FBPin with BNCT warrants a proper

  8. In vitro and in vivo comparison of binding of 99m-Tc-labeled anti-CEA MAb F33-104 with 99m-Tc-labeled anti-CEA MAb BW431/26.

    PubMed

    Watanabe, N; Oriuchi, N; Sugiyama, S; Kuroki, M; Matsuoka, Y; Tanada, S; Murata, H; Inoue, T; Sasaki, Y

    1999-01-01

    The purpose of this study was to assess the potential for radio-immunodetection (RAID) of murine anti-carcinoembryonic antigen (CEA) monoclonal antibody (MAb) F33-104 labeled with technetium-99m (99m-Tc) by a reduction-mediated labeling method. The binding capacity of 99m-Tc-labeled anti-CEA MAb F33-104 with CEA by means of in vitro procedures such as immunoradiometric assay and cell binding assay and the biodistribution of 99m-Tc-labeled anti-CEA MAb F33-104 in normal nude mice and nude mice bearing human colon adenocarcinoma LS180 tumor were investigated and compared with 99m-Tc-labeled anti-CEA MAb BW431/26. The in vitro binding rate of 99m-Tc-labeled anti-CEA MAb F33-104 with CEA in solution and attached to the cell membrane was significantly higher than 99m-Tc-labeled anti-CEA MAb BW431/261 (31.4 +/- 0.95% vs. 11.9 +/- 0.55% at 100 ng/mL of soluble CEA, 83.5 +/- 2.84% vs. 54.0 +/- 2.54% at 10(7) of LS 180 cells). In vivo, accumulation of 99m-Tc-labeled anti-CEA MAb F33-104 was higher at 18 h postinjection than 99m-Tc-labeled anti-CEA MAb BW431/26 (20.1 +/- 3.50% ID/g vs. 14.4 +/- 3.30% ID/g). 99m-Tc-activity in the kidneys of nude mice bearing tumor was higher at 18 h postinjection than at 3 h (12.8 +/- 2.10% ID/g vs. 8.01 +/- 2.40% ID/g of 99m-Tc-labeled anti-CEA MAb F33-104, 10.7 +/- 1.70% ID/g vs. 8.10 +/- 1.75% ID/g of 99m-Tc-labeled anti-CEA MAb BW431/26). 99m-Tc-labeled anti-CEA MAb F33-104 is a potential novel agent for RAID of recurrent colorectal cancer.

  9. An improved radiosynthesis of [18F]AV-133: a PET imaging agent for vesicular monoamine transporter 2.

    PubMed

    Zhu, Lin; Liu, Yajing; Plössl, Karl; Lieberman, Brian; Liu, Jingying; Kung, Hank F

    2010-02-01

    Recently, a PET tracer, 9-[(18)F]fluoropropyl-(+)-dihydrotetrabenazine ([(18)F]AV-133), targeting vesicular monoamine transporter 2 (VMAT2) in the central nervous system has been reported. It is currently under Phase II clinical trials to establish its usefulness in the diagnosis of neurodegenerative diseases including dementia with Lewy bodies and Parkinson's disease. The radiolabeling of [(18)F]AV-133, nucleophilic fluorination reaction and potential effects of pseudo-carrier were evaluated by in vivo biodistribution. The preparation of [(18)F]AV-133 was evaluated under different conditions, specifically by employing different precursors (-OTs or -Br as the leaving group at the 9-propoxy position), reagents (K222/K(2)CO(3) vs. tributylammonium bicarbonate) and solvents (acetonitrile vs. DMSO), reaction temperature and reaction time. With optimized conditions from these experiments, radiosynthesis and purification with solid-phase extraction (SPE) of [(18)F]AV-133 were performed by an automated nucleophilic [(18)F]fluorination module. In vivo biodistribution in mice on [(18)F]AV-133 purified by either HPLC (no-carrier-added) or the SPE method (containing a pseudo-carrier) was performed and the results compared. Under a mild fluorination condition (heating at 115 degrees C for 5 min in dimethyl sulfoxide), [(18)F]AV-133 was obtained in a high yield using either -OTs or -Br as the leaving group. However, the -OTs precursor gave better radiochemical yields (>70%, thin layer chromatography analysis) compared to those of the -Br precursor. The optimized reaction conditions were successfully implemented to an automated nucleophilic fluorination module. Labeling and purification of [(18)F]AV133 were readily achieved via this automatic module in good radiochemical yield of 21-41% (n=10) in 40 min. The radiochemical purity was larger than 95%. Biodistribution of SPE-purified product (containing a pseudo-carrier) in mice showed a high striatum/cerebellum ratio (4.18

  10. Characterization of 18F-FPyKYNE-Losartan for Imaging AT1 Receptors.

    PubMed

    Hachem, Maryam; Tiberi, Mario; Ismail, Basma; Hunter, Chad R; Arksey, Natasha; Hadizad, Tayebeh; Beanlands, Rob S; deKemp, Robert A; DaSilva, Jean N

    2016-10-01

    Most physiologic effects of the renin angiotensin system (RAS) are mediated via the angiotensin (Ang) type 1 receptor (AT 1 R). The 18 F-FPyKYNE derivative of the clinically used AT 1 R blocker losartan exhibits high binding selectivity for kidney AT 1 R and rapid metabolism in rats. The aim of this study was to further assess the binding profile of this novel PET agent for imaging AT 1 R in rats and pigs. In vitro binding assays were performed with 18 F-FPyKYNE-losartan in rat kidneys. Male Sprague-Dawley rats were used to assess dosimetry, antagonistic efficacy via blood pressure measurements, and presence of labeled metabolites in kidneys. Test-retest PET imaging, blocking with AT 1 R antagonist candesartan (10 mg/kg), and plasma metabolism analysis were performed in female Yorkshire pigs. 18 F-FPyKYNE-losartan bound with high affinity (dissociation constant of 49.4 ± 18.0 nM and maximal binding of 348 ± 112 fmol/mm 2 ) to rat kidney AT 1 R. It bound strongly to plasma proteins in rats (97%), and its labeled metabolites displayed minimal interference on renal AT 1 R binding. FPyKYNE-losartan fully antagonized the Ang II pressor effect, albeit with 4-fold potency reduction (the effective dose inhibiting 50% of the Ang II-induced maximal pressor response of 25.5 mg/kg) relative to losartan. PET imaging exhibited high kidney-to-blood contrast and slow renal clearance, with an SUV of 14.1 ± 6.2. Excellent reproducibility was observed in the calculated test-retest variability (7.2% ± 0.75%). Only hydrophilic-labeled metabolites were present in plasma samples, and renal retention was reduced (-60%) at 10-15 min after blockade with candesartan. 18 F-FPyKYNE-losartan has a favorable binding profile and displays high potential for translational work in humans as an AT 1 R PET imaging agent. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  11. PET Imaging of Fatty Acid Amide Hydrolase with [ 18F]DOPP in Nonhuman Primates

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rotstein, Benjamin H.; Wey, Hsiao -Ying; Shoup, Timothy M.

    Here, the fatty acid amide hydrolase (FAAH) regulates endocannabinoid signaling. [ 11C]CURB, an irreversibly binding FAAH inhibitor, has been developed for clinical research imaging with PET. However, no fluorine-18 labeled radiotracer for FAAH has yet advanced to human studies. [ 18F]DOPP ([ 18F]3-(4,5-dihydrooxazol-2-yl)phenyl (5-fluoropentyl)carbamate) has been identified as a promising 18F-labeled analogue based on rodent studies. The goal of this work is to evaluate [ 18F]DOPP in nonhuman primates to support its clinical translation. High specific activity [ 18F]DOPP (5–6 Ci·μmol –1) was administered intravenously (iv) to three baboons (2M/1F, 3–4 years old). The distribution and pharmacokinetics were quantified followingmore » a 2 h dynamic imaging session using a simultaneous PET/MR scanner. Pretreatment with the FAAH-selective inhibitor, URB597, was carried out at 200 or 300 μg/kg iv, 10 min prior to [ 18F]DOPP administration. Rapid arterial blood sampling for the first 3 min was followed by interval sampling with metabolite analysis to provide a parent radiotracer plasma input function that indicated ~95% baseline metabolism at 60 min and a reduced rate of metabolism after pretreatment with URB597. Regional distribution data were analyzed with 1-, 2-, and 3-tissue compartment models (TCMs), with and without irreversible trapping since [ 18F]DOPP covalently links to the active site of FAAH. Consistent with previous findings for [ 11C]CURB, the 2TCM with irreversible binding was found to provide the best fit for modeling the data in all regions. The composite parameter λk 3 was therefore used to evaluate whole brain (WB) and regional binding of [ 18F]DOPP. Pretreatment studies showed inhibition of λk 3 across all brain regions (WB baseline: 0.112 mL/cm3/min; 300 μg/kg URB597: 0.058 mL/cm 3/min), suggesting that [ 18F]DOPP binding is specific for FAAH, consistent with previous rodent data.« less

  12. PET Imaging of Fatty Acid Amide Hydrolase with [ 18F]DOPP in Nonhuman Primates

    DOE PAGES

    Rotstein, Benjamin H.; Wey, Hsiao -Ying; Shoup, Timothy M.; ...

    2014-07-08

    Here, the fatty acid amide hydrolase (FAAH) regulates endocannabinoid signaling. [ 11C]CURB, an irreversibly binding FAAH inhibitor, has been developed for clinical research imaging with PET. However, no fluorine-18 labeled radiotracer for FAAH has yet advanced to human studies. [ 18F]DOPP ([ 18F]3-(4,5-dihydrooxazol-2-yl)phenyl (5-fluoropentyl)carbamate) has been identified as a promising 18F-labeled analogue based on rodent studies. The goal of this work is to evaluate [ 18F]DOPP in nonhuman primates to support its clinical translation. High specific activity [ 18F]DOPP (5–6 Ci·μmol –1) was administered intravenously (iv) to three baboons (2M/1F, 3–4 years old). The distribution and pharmacokinetics were quantified followingmore » a 2 h dynamic imaging session using a simultaneous PET/MR scanner. Pretreatment with the FAAH-selective inhibitor, URB597, was carried out at 200 or 300 μg/kg iv, 10 min prior to [ 18F]DOPP administration. Rapid arterial blood sampling for the first 3 min was followed by interval sampling with metabolite analysis to provide a parent radiotracer plasma input function that indicated ~95% baseline metabolism at 60 min and a reduced rate of metabolism after pretreatment with URB597. Regional distribution data were analyzed with 1-, 2-, and 3-tissue compartment models (TCMs), with and without irreversible trapping since [ 18F]DOPP covalently links to the active site of FAAH. Consistent with previous findings for [ 11C]CURB, the 2TCM with irreversible binding was found to provide the best fit for modeling the data in all regions. The composite parameter λk 3 was therefore used to evaluate whole brain (WB) and regional binding of [ 18F]DOPP. Pretreatment studies showed inhibition of λk 3 across all brain regions (WB baseline: 0.112 mL/cm3/min; 300 μg/kg URB597: 0.058 mL/cm 3/min), suggesting that [ 18F]DOPP binding is specific for FAAH, consistent with previous rodent data.« less

  13. Site specific measurements of bone formation using [18F] sodium fluoride PET/CT

    PubMed Central

    Puri, Tanuj; Siddique, Musib; Frost, Michelle L.; Moore, Amelia E. B.; Fogelman, Ignac

    2018-01-01

    Dynamic positron emission tomography (PET) imaging with fluorine-18 labelled sodium fluoride ([18F]NaF) allows the quantitative assessment of regional bone formation by measuring the plasma clearance of fluoride to bone at any site in the skeleton. Today, hybrid PET and computed tomography (CT) dual-modality systems (PET/CT) are widely available, and [18F]NaF PET/CT offers a convenient non-invasive method of studying bone formation at the important osteoporotic fracture sites at the hip and spine, as well as sites of pure cortical or trabecular bone. The technique complements conventional measurements of bone turnover using biochemical markers or bone biopsy as a tool to investigate new therapies for osteoporosis, and has a potential role as an early biomarker of treatment efficacy in clinical trials. This article reviews methods of acquiring and analyzing dynamic [18F]NaF PET/CT scan data, and outlines a simplified approach combining venous blood sampling with a series of short (3- to 5-minute) static PET/CT scans acquired at different bed positions to estimate [18F]NaF plasma clearance at multiple sites in the skeleton with just a single injection of tracer. PMID:29541623

  14. Site specific measurements of bone formation using [18F] sodium fluoride PET/CT.

    PubMed

    Blake, Glen M; Puri, Tanuj; Siddique, Musib; Frost, Michelle L; Moore, Amelia E B; Fogelman, Ignac

    2018-02-01

    Dynamic positron emission tomography (PET) imaging with fluorine-18 labelled sodium fluoride ([ 18 F]NaF) allows the quantitative assessment of regional bone formation by measuring the plasma clearance of fluoride to bone at any site in the skeleton. Today, hybrid PET and computed tomography (CT) dual-modality systems (PET/CT) are widely available, and [ 18 F]NaF PET/CT offers a convenient non-invasive method of studying bone formation at the important osteoporotic fracture sites at the hip and spine, as well as sites of pure cortical or trabecular bone. The technique complements conventional measurements of bone turnover using biochemical markers or bone biopsy as a tool to investigate new therapies for osteoporosis, and has a potential role as an early biomarker of treatment efficacy in clinical trials. This article reviews methods of acquiring and analyzing dynamic [ 18 F]NaF PET/CT scan data, and outlines a simplified approach combining venous blood sampling with a series of short (3- to 5-minute) static PET/CT scans acquired at different bed positions to estimate [ 18 F]NaF plasma clearance at multiple sites in the skeleton with just a single injection of tracer.

  15. PSA-Stratified Performance of 18F- and 68Ga-PSMA PET in Patients with Biochemical Recurrence of Prostate Cancer.

    PubMed

    Dietlein, Felix; Kobe, Carsten; Neubauer, Stephan; Schmidt, Matthias; Stockter, Simone; Fischer, Thomas; Schomäcker, Klaus; Heidenreich, Axel; Zlatopolskiy, Boris D; Neumaier, Bernd; Drzezga, Alexander; Dietlein, Markus

    2017-06-01

    Several studies outlined the sensitivity of 68 Ga-labeled PET tracers against the prostate-specific membrane antigen (PSMA) for localization of relapsed prostate cancer in patients with renewed increase in the prostate-specific antigen (PSA), commonly referred to as biochemical recurrence. Labeling of PSMA tracers with 18 F offers numerous advantages, including improved image resolution, longer half-life, and increased production yields. The aim of this study was to assess the PSA-stratified performance of the 18 F-labeled PSMA tracer 18 F-DCFPyL and the 68 Ga-labeled reference 68 Ga-PSMA-HBED-CC. Methods: We examined 191 consecutive patients with biochemical recurrence according to standard acquisition protocols using 18 F-DCFPyL ( n = 62, 269.8 MBq, PET scan at 120 min after injection) or 68 Ga-PSMA-HBED-CC ( n = 129, 158.9 MBq, 60 min after injection). We determined PSA-stratified sensitivity rates for both tracers and corrected our calculations for Gleason scores using iterative matched-pair analyses. As an orthogonal validation, we directly compared tracer distribution patterns in a separate cohort of 25 patients, sequentially examined with both tracers. Results: After prostatectomy ( n = 106), the sensitivity of both tracers was significantly associated with absolute PSA levels ( P = 4.3 × 10 -3 ). Sensitivity increased abruptly, when PSA values exceeded 0.5 μg/L ( P = 2.4 × 10 -5 ). For a PSA less than 3.5 μg/L, most relapses were diagnosed at a still limited stage ( P = 3.4 × 10 -6 ). For a PSA of 0.5-3.5 μg/L, PSA-stratified sensitivity was 88% (15/17) for 18 F-DCFPyL and 66% (23/35) for 68 Ga-PSMA-HBED-CC. This significant difference was preserved in the Gleason-matched-pair analysis. Outside of this range, sensitivity was comparably low (PSA < 0.5 μg/L) or high (PSA > 3.5 μg/L). After radiotherapy ( n = 85), tracer sensitivity was largely PSA-independent. In the 25 patients examined with both tracers, distribution patterns of 18 F-DCFPyL and 68

  16. Diagnostic impact of PET with 18F-FDG, 18F-DOPA and 3-O-methyl-6-[18F]fluoro-DOPA in recurrent or metastatic medullary thyroid carcinoma.

    PubMed

    Beuthien-Baumann, B; Strumpf, A; Zessin, J; Bredow, J; Kotzerke, J

    2007-10-01

    In patients with medullary thyroid carcinoma (MTC), rising levels of the tumour markers calcitonin and CEA after primary surgery indicate tumour recurrence or metastases. The only chance of cure is the resection of localised tumour tissue. For positron emission tomography (PET) with (18)F-fluorodeoxyglucose ((18)F-FDG) and (18)F-dihydroxyphenylalanine ((18)F-DOPA), sensitivities of 78% and 63% have been reported, but in a considerable percentage of MTC patients the source of tumour marker elevation is not detected. The aim of this retrospective data evaluation was to compare the value of PET with (18)F-FDG, (18)F-DOPA and the amino acid tracer 3-O-methyl-6-[(18)F]fluoro-DOPA ((18)F-OMFD) in the detection of MTC recurrence. Fifteen patients with elevated calcitonin were investigated with PET as part of their individual clinical work-up. All patients underwent (18)F-FDG PET and (18)F-DOPA PET, and ten patients underwent (18)F-OMFD PET. With (18)F-FDG, seven patients showed foci in the neck, mediastinum, upper abdomen or bone. In seven patients, (18)F-DOPA revealed suspicious foci; five of these seven patients showed partially corresponding uptake of (18)F-FDG in the neck and mediastinum. Two of these patients underwent surgery and metastases were verified. With (18)F-OMFD, a small focus in the liver was suspected in one patient without a correlate on (18)F-FDG PET, (18)F-DOPA PET or conventional imaging. (18)F-FDG and (18)F-DOPA showed foci that were highly suspicious for local recurrence or metastasis of MTC, although histological verification in these patients with numerous previous surgical interventions was performed in only two patients. The amino acid tracer (18)F-OMFD had no diagnostic impact in these patients.

  17. Synthesis and preclinical characterization of [18F]FPBZA: a novel PET probe for melanoma.

    PubMed

    Wu, Shih-Yen; Huang, Shih-Pin; Lo, Yen-Chen; Liu, Ren-Shyan; Wang, Shyh-Jen; Lin, Wuu-Jyh; Shen, Chih-Chieh; Wang, Hsin-Ell

    2014-01-01

    Benzamide can specifically bind to melanoma cells. A 18F-labeled benzamide derivative, [18F]N-(2-diethylaminoethyl)-4-[2-(2-(2-fluoroethoxy) ethoxy)ethoxy]benzamide ([18F]FPBZA), was developed as a promising PET probe for primary and metastatic melanoma. [18F]FPBZA was synthesized via a one-step radiofluorination in this study. The specific uptake of [18F]FPBZA was studied in B16F0 melanoma cells, A375 amelanotic melanoma cells, and NB-DNJ-pretreated B16F0 melanoma cells. The biological characterization of [18F]FPBZA was performed on mice bearing B16F0 melanoma, A375 amelanotic melanoma, or inflammation lesion. [18F]FPBZA can be prepared efficiently with a yield of 40-50%. The uptake of [18F]FPBZA by B16F0 melanoma cells was significantly higher than those by A375 tumor cells and NB-DNJ-pretreated B16F0 melanoma cells. B16F0 melanoma displayed prominent uptake of [18F]FPBZA at 2 h (7.81±0.82%ID/g), compared with A375 tumor and inflammation lesion (3.00±0.71 and 1.67±0.56%ID/g, resp.). [18F]FPBZA microPET scan clearly delineated B16F0 melanoma but not A375 tumor and inflammation lesion. In mice bearing pulmonary metastases, the lung radioactivity reached 4.77±0.36%ID/g at 2 h (versus 1.16±0.23%ID/g in normal mice). Our results suggested that [18F]FPBZA PET would provide a promising and specific approach for the detection of primary and metastatic melanoma lesions.

  18. 18F-FDG or 3'-deoxy-3'-18F-fluorothymidine to detect transformation of follicular lymphoma.

    PubMed

    Wondergem, Marielle J; Rizvi, Saiyada N F; Jauw, Yvonne; Hoekstra, Otto S; Hoetjes, Nikie; van de Ven, Peter M; Boellaard, Ronald; Chamuleau, Martine E D; Cillessen, Saskia A G M; Regelink, Josien C; Zweegman, Sonja; Zijlstra, Josée M

    2015-02-01

    Considering the different treatment strategy for transformed follicular lymphoma (TF) as opposed to follicular lymphoma (FL), diagnosing transformation early in the disease course is important. There is evidence that (18)F-FDG has utility as a biomarker of transformation. However, quantitative thresholds may require inclusion of homogeneous non-Hodgkin lymphoma subtypes to account for differences in tracer uptake per subtype. Moreover, because proliferation is a hallmark of transformation, 3'-deoxy-3'-(18)F-fluorothymidine ((18)F-FLT) might be superior to (18)F-FDG in this setting. To define the best tracer for detection of TF, we performed a prospective a head-to-head comparison of (18)F-FDG and (18)F-FLT in patients with FL and TF. (18)F-FDG and (18)F-FLT PET scans were obtained in 17 patients with FL and 9 patients with TF. We measured the highest maximum standardized uptake value (SUVmax), defined as the lymph node with the highest uptake per patient, and SUVrange, defined as the difference between the SUVmax of the lymph node with the highest and lowest uptake per patient. To reduce partial-volume effects, only lymph nodes larger than 3 cm(3) (A50 isocontour) were analyzed. Scans were acquired 1 h after injection of 185 MBq of (18)F-FDG or (18)F-FLT. To determine the discriminative ability of SUVmax and SUVrange of both tracers for TF, receiver-operating-characteristic curve analysis was performed. The highest SUVmax was significantly higher for TF than FL for both (18)F-FDG and (18)F-FLT (P < 0.001). SUVrange was significantly higher for TF than FL for (18)F-FDG (P = 0.029) but not for (18)F-FLT (P = 0.075). The ability of (18)F-FDG to discriminate between FL and TF was superior to that of (18)F-FLT for both the highest SUVmax (P = 0.039) and the SUVrange (P = 0.012). The cutoff value for the highest SUVmax of (18)F-FDG aiming at 100% sensitivity with a maximum specificity was found to be 14.5 (corresponding specificity, 82%). For (18)F-FLT, these values were

  19. Depicting changes in tumor biology in response to cetuximab mono- or combination therapy by apoptosis and proliferation imaging using 18F-ICMT-11 and 3'-Deoxy-3'-[18F]Fluorothymidine (18F-FLT) PET.

    PubMed

    Heinzmann, Kathrin; Nguyen, Quang-De; Honess, Davina Jean; Smith, Donna-Michelle; Stribbling, Stephen; Brickute, Diana; Barnes, Christopher; Griffiths, John Richard; Aboagye, Eric Ofori

    2018-05-24

    Imaging biomarkers must demonstrate their value in monitoring treatment. Two PET tracers, the caspase-3/7-specific isatin-5-sulfonamide 18 F-ICMT-11 and 3'-Deoxy-3'-[ 18 F]Fluorothymidine ( 18 F-FLT), were employed to detect early treatment-induced changes in tumor biology and whether any changes indicate response to cetuximab, administered as mono- or combination therapy with gemcitabine. Methods: Effects of single or repeated doses of the anti-Epidermal Growth Factor Receptor (EGFR) antibody cetuximab (10mg/kg on day 1 only or day 1 and 2) and/or a single dose of gemcitabine (125mg/kg; day 2) were investigated in mice bearing cetuximab-sensitive H1975 tumors (non-small cell lung cancer) by 18 F-ICMT-11 or 18 F-FLT-PET (day 3). Imaging was also performed in mice bearing cetuximab-insensitive HCT116 tumors (colorectal cancer) after two doses of cetuximab (day 1 and 2). For imaging/histology comparison, tumors were evaluated for proliferation (Ki67; thymidine kinase 1, TK1), cell death (cleaved caspase-3, terminal deoxynucleotidyl transferase-mediated dUTP nick-end labelling (TUNEL)) and target engagement (EGFR expression) by immunohistochemistry, immunofluorescence and immunoblot, respectively. Tumor and plasma were analysed for thymidine and gemcitabine metabolites by liquid chromatography-mass spectrometry. Results: Retention of both tracers was sensitive to cetuximab in H1975 tumors. 18 F-ICMT-11 uptake and ex vivo cleaved caspase-3 staining notably increased in tumors treated with repeated doses of cetuximab- (75%) and combination-treatment (46%). While one dose of cetuximab was insufficient to induce apoptosis it did affect proliferation. Significant reduction in tumor 18 F-FLT uptake (44 to 50%; P < 0.001) induced by cetuximab mono- and combination-therapy were paralleled with a clear decrease in proliferation (%Ki67 decrease: 72 to 95%; P < 0.0001) and followed by marked tumor growth delay. TK1 expression and tumor thymidine concentrations were profoundly

  20. Continuous-Flow Synthesis of N-Succinimidyl 4-[18F]fluorobenzoate Using a Single Microfluidic Chip

    PubMed Central

    Kimura, Hiroyuki; Tomatsu, Kenji; Saiki, Hidekazu; Arimitsu, Kenji; Ono, Masahiro; Kawashima, Hidekazu; Iwata, Ren; Nakanishi, Hiroaki; Ozeki, Eiichi; Kuge, Yuji; Saji, Hideo

    2016-01-01

    In the field of positron emission tomography (PET) radiochemistry, compact microreactors provide reliable and reproducible synthesis methods that reduce the use of expensive precursors for radiolabeling and make effective use of the limited space in a hot cell. To develop more compact microreactors for radiosynthesis of 18F-labeled compounds required for the multistep procedure, we attempted radiosynthesis of N-succinimidyl 4-[18F]fluorobenzoate ([18F]SFB) via a three-step procedure using a microreactor. We examined individual steps for [18F]SFB using a batch reactor and microreactor and developed a new continuous-flow synthetic method with a single microfluidic chip to achieve rapid and efficient radiosynthesis of [18F]SFB. In the synthesis of [18F]SFB using this continuous-flow method, the three-step reaction was successfully completed within 6.5 min and the radiochemical yield was 64 ± 2% (n = 5). In addition, it was shown that the quality of [18F]SFB synthesized on this method was equal to that synthesized by conventional methods using a batch reactor in the radiolabeling of bovine serum albumin with [18F]SFB. PMID:27410684

  1. Synthesis and preclinical evaluation of an Al18F radiofluorinated GLU-UREA-LYS(AHX)-HBED-CC PSMA ligand

    PubMed Central

    Boschi, Stefano; Lee, Jason T.; Beykan, Seval; Slavik, Roger; Wei, Liu; Spick, Claudio; Eberlein, Uta; Buck, Andreas K.; Lodi, Filippo; Cicoria, Gianfranco; Czernin, Johannes; Lassmann, Michael; Fanti, Stefano; Herrmann, Ken

    2016-01-01

    Purpose The aim of this study was to synthesize and preclinically evaluate an 18F-PSMA positron emission tomography (PET) tracer. Prostate-specific membrane antigen (PSMA) specificity, biodistribution, and dosimetry in healthy and tumor-bearing mice were determined. Methods Several conditions for the labeling of 18F-PSMA-11 via 18F-AlF-complexation were screened to study the influence of reaction temperature, peptide amount, ethanol volume, and reaction time. After synthesis optimization, biodistribution and dosimetry studies were performed in C57BL6 mice. For proof of PSMA-specificity, mice were implanted with PSMA-negative (PC3) and PSMA-positive (LNCaP) tumors in contralateral flanks. Static and dynamic microPET/computed tomography (CT) imaging was performed. Results Quantitative labeling yields could be achieved with >97 % radiochemical purity. The 18F-PSMA-11 uptake was more than 24-fold higher in PSMA-high LNCaP than in PSMA-low PC3 tumors (18.4 ± 3.3 %ID/g and 0.795 ± 0.260 %ID/g, respectively; p < 4.2e-5). Results were confirmed by ex vivo gamma counter analysis of tissues after the last imaging time point. The highest absorbed dose was reported for the kidneys. The maximum effective dose for an administered activity of 200 MBq was 1.72 mSv. Conclusion 18F-PSMA-11 using direct labeling of chelate-attached peptide with aluminum-fluoride detected PSMA-expressing tumors with high tumor-to-liver ratios. The kidneys were the dose-limiting organs. Even by applying the most stringent dosimetric calculations, injected activities of up to 0.56 GBq are feasible. PMID:27329046

  2. Synthesis and preclinical evaluation of an Al18F radiofluorinated GLU-UREA-LYS(AHX)-HBED-CC PSMA ligand.

    PubMed

    Boschi, Stefano; Lee, Jason T; Beykan, Seval; Slavik, Roger; Wei, Liu; Spick, Claudio; Eberlein, Uta; Buck, Andreas K; Lodi, Filippo; Cicoria, Gianfranco; Czernin, Johannes; Lassmann, Michael; Fanti, Stefano; Herrmann, Ken

    2016-11-01

    The aim of this study was to synthesize and preclinically evaluate an 18 F-PSMA positron emission tomography (PET) tracer. Prostate-specific membrane antigen (PSMA) specificity, biodistribution, and dosimetry in healthy and tumor-bearing mice were determined. Several conditions for the labeling of 18 F-PSMA-11 via 18 F-AlF-complexation were screened to study the influence of reaction temperature, peptide amount, ethanol volume, and reaction time. After synthesis optimization, biodistribution and dosimetry studies were performed in C57BL6 mice. For proof of PSMA-specificity, mice were implanted with PSMA-negative (PC3) and PSMA-positive (LNCaP) tumors in contralateral flanks. Static and dynamic microPET/computed tomography (CT) imaging was performed. Quantitative labeling yields could be achieved with >97 % radiochemical purity. The 18 F-PSMA-11 uptake was more than 24-fold higher in PSMA-high LNCaP than in PSMA-low PC3 tumors (18.4 ± 3.3 %ID/g and 0.795 ± 0.260 %ID/g, respectively; p < 4.2e-5). Results were confirmed by ex vivo gamma counter analysis of tissues after the last imaging time point. The highest absorbed dose was reported for the kidneys. The maximum effective dose for an administered activity of 200 MBq was 1.72 mSv. 18 F-PSMA-11 using direct labeling of chelate-attached peptide with aluminum-fluoride detected PSMA-expressing tumors with high tumor-to-liver ratios. The kidneys were the dose-limiting organs. Even by applying the most stringent dosimetric calculations, injected activities of up to 0.56 GBq are feasible.

  3. Synthesis of a D-Glucopyranosyl Azide: Spectroscopic Evidence for Stereochemical Inversion in the S[subscript N]2 Reaction

    ERIC Educational Resources Information Center

    Adesoye, Olumuyiwa G.; Mills, Isaac N.; Temelkoff, David P.; Jackson, John A.; Norris, Peter

    2012-01-01

    Stereospecific S[subscript N]2 conversion of configurationally pure acetobromoglucose (2,3,4,6-tetra-O-acetyl-alpha-D-glucopyranosyl bromide) to the corresponding beta-D-glucopyranosyl azide is a useful exercise in the advanced organic undergraduate teaching laboratory. The procedure is safe and suitable for small-scale implementation, and firm…

  4. [(18)F]Florbetaben: a review in β-amyloid PET imaging in cognitive impairment.

    PubMed

    Syed, Yahiya Y; Deeks, Emma

    2015-07-01

    Intravenous (18)F-labelled florbetaben ([(18)F]florbetaben) [Neuraceq™] is a polyethylene glycol stilbene derivative that is approved in the USA, EU and South Korea for positron emission tomography (PET) imaging of the brain. It is used to estimate β-amyloid neuritic plaque density in adult patients with cognitive impairment who are being evaluated for Alzheimer's disease and other causes of cognitive impairment. In vitro, [(18)F]florbetaben has high affinity and selectivity for β-amyloid. It has a short PET scan time (15-20 min). Visual assessment of regional and whole brain [(18)F]florbetaben PET images detected brain β-amyloid with high sensitivity and specificity, with good inter-reader agreement, in a phase III study in patients with various levels of cognitive function when compared with postmortem histopathological assessment. The whole brain visual assessment displayed high positive and negative predictive values, enabling amyloid pathology to be reliably detected or excluded. Quantitative PET analyses were generally consistent with the visual assessments. [(18)F]florbetaben was generally well tolerated in clinical trials. All adverse reactions in [(18)F]florbetaben recipients were mild to moderate in severity and the most common were injection-site-related (erythema, irritation and pain). There were no serious adverse reactions related to [(18)F]florbetaben. In summary, [(18)F]florbetaben is a highly accurate β-amyloid PET tracer that has the potential to support the clinical diagnosis of Alzheimer's disease and other causes of cognitive decline.

  5. Evaluation of 18F-labeled targeted perfluorocarbon-filled albumin microbubbles as a probe for microUS and microPET in tumor-bearing mice.

    PubMed

    Liao, Ai-Ho; Wu, Shih-Yen; Wang, Hsin-Ell; Weng, Chien-Hsiu; Wu, Ming-Fang; Li, Pai-Chi

    2013-02-01

    In this study, albumin-shelled, targeted MBs (tMBs) were first demonstrated with the expectation of visualization of biodistribution of albumin-shelled tMBs. The actual biodistribution of albumin-shelled tMBs is of vital importance either for molecular imaging or for drug delivery. Recently, albumin microbubbles (MBs) have been studied for drug and gene delivery in vitro and in vivo through cavitation. Targeted lipid-shelled MBs have been applied for ultrasound molecular imaging and conjugated with radiolabeled antibodies for whole-body biodistribution evaluations. The novelty of the work is that, in addition to the lipid tMBs, the albumin tMBs was also applied in biodistribution detection. Multimodality albumin-shelled, (18)F-SFB-labeled VEGFR2 tMBs were synthesized, and their characteristics in mice bearing MDA-MB-231 human breast cancer were investigated with micro-positron-emission tomography (microPET) and high-frequency ultrasound (microUS). Albumin-shelled MBs can be labeled with (18)F-SFB directly and conjugated with antibodies for dual molecular imaging. The albumin-shelled tMBs show a lifetime in 30min in the blood pool and a highly specific adherence to tumor vessels in mice bearing human breast cancer. From the evaluations of whole-body biodistribution, the potential of the dual molecular imaging probe for drug or gene delivery in animal experiments with albumin shelled MBs has been investigated. Copyright © 2012 Elsevier B.V. All rights reserved.

  6. Synthesis and Preclinical Characterization of [18F]FPBZA: A Novel PET Probe for Melanoma

    PubMed Central

    Huang, Shih-Pin; Lo, Yen-Chen; Liu, Ren-Shyan; Shen, Chih-Chieh

    2014-01-01

    Introduction. Benzamide can specifically bind to melanoma cells. A 18F-labeled benzamide derivative, [18F]N-(2-diethylaminoethyl)-4-[2-(2-(2-fluoroethoxy) ethoxy)ethoxy]benzamide ([18F]FPBZA), was developed as a promising PET probe for primary and metastatic melanoma. Methods. [18F]FPBZA was synthesized via a one-step radiofluorination in this study. The specific uptake of [18F]FPBZA was studied in B16F0 melanoma cells, A375 amelanotic melanoma cells, and NB-DNJ-pretreated B16F0 melanoma cells. The biological characterization of [18F]FPBZA was performed on mice bearing B16F0 melanoma, A375 amelanotic melanoma, or inflammation lesion. Results. [18F]FPBZA can be prepared efficiently with a yield of 40–50%. The uptake of [18F]FPBZA by B16F0 melanoma cells was significantly higher than those by A375 tumor cells and NB-DNJ-pretreated B16F0 melanoma cells. B16F0 melanoma displayed prominent uptake of [18F]FPBZA at 2 h (7.81 ± 0.82 %ID/g), compared with A375 tumor and inflammation lesion (3.00 ± 0.71 and 1.67 ± 0.56 %ID/g, resp.). [18F]FPBZA microPET scan clearly delineated B16F0 melanoma but not A375 tumor and inflammation lesion. In mice bearing pulmonary metastases, the lung radioactivity reached 4.77 ± 0.36 %ID/g at 2 h (versus 1.16 ± 0.23 %ID/g in normal mice). Conclusions. Our results suggested that [18F]FPBZA PET would provide a promising and specific approach for the detection of primary and metastatic melanoma lesions. PMID:25254219

  7. Use of [18F]FDG PET to Monitor The Development of Cardiac Allograft Rejection

    PubMed Central

    Daly, Kevin P.; Dearling, Jason L. J.; Seto, Tatsuichiro; Dunning, Patricia; Fahey, Frederic; Packard, Alan B.; Briscoe, David M.

    2014-01-01

    Background Positron Emission Tomography (PET) has the potential to be a specific, sensitive and quantitative diagnostic test for transplant rejection. To test this hypothesis, we evaluated 18F-labeled fluorodeoxyglucose ([18F]FDG) and 13N-labeled ammonia ([13N]NH3) small animal PET imaging in a well-established murine cardiac rejection model. Methods Heterotopic transplants were performed using minor MHC mismatched B6.C-H2bm12 donor hearts in C57BL/6(H-2b) recipients. C57BL/6 donor hearts into C57BL/6 recipients served as isograft controls. [18F]FDG PET imaging was performed weekly between post-transplant days 7 and 42 and the percent injected dose was computed for each graft. [13N]NH3 imaging was performed to evaluate myocardial perfusion. Results There was a significant increase in [18F]FDG uptake in allografts from day 14 to day 21 (1.6% to 5.2%; P<0.001) and uptake in allografts was significantly increased on post-transplant days 21 (5.2% vs. 0.9%; P=0.005) and 28 (4.8% vs. 0.9%; P=0.006) compared to isograft controls. Furthermore, [18F]FDG uptake correlated with an increase in rejection within allografts between days 14 and 28 post-transplant. Finally, the uptake of [13N]NH3 was significantly lower relative to the native heart in allografts with chronic vasculopathy compared to isograft controls on day 28 (P=0.01). Conclusions PET imaging with [18F]FDG can be used following transplantation to monitor the evolution of rejection. In addition, decreased uptake of [13N]NH3 in rejecting allografts may be reflective of decreased myocardial blood flow. These data suggest that combined [18F]FDG and [13N]NH3 PET imaging could be used as a non-invasive, quantitative technique for serial monitoring of allograft rejection and has potential application in human transplant recipients. PMID:25675207

  8. 27 CFR 18.55 - Label.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2011-04-01 2011-04-01 false Label. 18.55 Section 18.55 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE... Management and Budget under control number 1512-0098) [T.D. ATF-104, 47 FR 23921, June 2, 1982, as amended by...

  9. (18)F-glyco-RGD peptides for PET imaging of integrin expression: efficient radiosynthesis by click chemistry and modulation of biodistribution by glycosylation.

    PubMed

    Maschauer, Simone; Haubner, Roland; Kuwert, Torsten; Prante, Olaf

    2014-02-03

    Glycosylation frequently improves the biokinetics and clearance properties of macromolecules in vivo and could therefore be used for the design of radiopharmaceuticals for positron emission tomography (PET). Recently, we have developed a click chemistry method for (18)F-fluoroglycosylation of alkyne-bearing RGD-peptides targeting the integrin receptor. To investigate whether this strategy could yield an (18)F-labeled RGD glycopeptide with favorable biokinetics, we generated a series of new RGD glycopeptides, varying the 6-fluoroglycosyl residue from monosaccharide to disaccharide units, which provided the glucosyl ([(19)F]6Glc-RGD, 4b), galactosyl ([(19)F]Gal-RGD, 4c), maltosyl ([(19)F]Mlt-RGD, 4e), and cellobiosyl ([(19)F]Cel-RGD, 4f) conjugated peptides in high yields and purities of >97%. All of these RGD glycopeptides showed high affinity to αvβ3 (11-55 nM), αvβ5 (6-14 nM), and to αvβ3-positive U87MG cells (90-395 nM). (18)F-labeling of the various carbohydrate precursors (1a-f) using cryptate-assisted reaction conditions (CH3CN, 85 °C, 10 min) gave (18)F-labeled glycosyl azides in radiochemical yields (RCYs) of up to 84% ([(18)F]2b). The deacetylation and subsequent click reaction with the alkyne-bearing cyclic RGD peptide proceeded in one-pot reactions with RCYs as high as 81% in 15-20 min at 60 °C, using a minimal amount of peptide precursor (100 nmol). Optimization of the radiosynthesis strategy gave a decay-uncorrected RCY of 16-24% after 70-75 min (based on [(18)F]fluoride). Due to their high-yield radiosyntheses, the glycopeptides [(18)F]6Glc-RGD and [(18)F]Mlt-RGD were chosen for comparative biodistribution studies and dynamic small-animal PET imaging using U87MG tumor-bearing nude mice. [(18)F]6Glc-RGD and [(18)F]Mlt-RGD showed significantly decreased liver and kidney uptake by PET relative to the 2-[(18)F]fluoroglucosyl analog [(18)F]2Glc-RGD, and showed specific tumor uptake in vivo. Notably, [(18)F]Mlt-RGD revealed uptake and retention in

  10. Cancer Localization in the Prostate with F-18 Fluorocholine Position Emission Tomography

    DTIC Science & Technology

    2008-01-01

    R , Ward E, Murray T , Xu J, Thun MJ. Cancer statistics, 2007. CA...2007. 8 C C S F I l p m p t f a i l z i m m * † ‡ § S A 4 ancer Imaging With Fluorine-18Labeled holine Derivatives andi A. Kwee, MD,*,† Timothy R ...prostate cancer imaging. v i s f b t r h i K n u f t B l t i m i F s i b a d i s w l l o t c p P i p w t h d p 422 S.A. Kwee

  11. Novel synthesis and initial preclinical evaluation of (18)F-[FDG] labeled rhodamine: a potential PET myocardial perfusion imaging agent.

    PubMed

    AlJammaz, Ibrahim; Al-Otaibi, Basim; AlHindas, Hussein; Okarvi, Subhani M

    2015-10-01

    Myocardial perfusion imaging is one of the most commonly performed investigations in nuclear medicine studies. Due to the clinical importance of [(18)F]-fluoro-2-deoxy-D-glucose ([(18)F]-FDG) and its availability in almost every PET center, a new radiofluorinated [(18)F]-FDG-rhodamine conjugate was synthesized using [(18)F]-FDG as a prosthetic group. In a convenient and simple one-step radiosynthesis, [(18)F]-FDG-rhodamine conjugate was prepared in quantitative radiochemical yields, with total synthesis time of nearly 20 min and radiochemical purity of greater than 98%, without the need for HPLC purification, which make these approaches amenable for automation. Biodistribution studies in normal rats at 60 min post-injection demonstrated a high uptake in the heart (>11% ID/g) and favorable pharmacokinetics. Additionally, [(18)F]-FDG-rhodamine showed an extraction value of 27.63%±5.12% in rat hearts. These results demonstrate that [(18)F]-FDG-rhodamine conjugate may be useful as an imaging agent for the positron emission tomography evaluation of myocardial perfusion. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. 19 CFR 12.18 - Labels.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... OF MERCHANDISE Viruses, Serums, and Toxins for Treatment of Domestic Animals § 12.18 Labels. Each separate container of such virus, serum, toxin, or analogous product imported is required by the...

  13. Fluorine-18-labeled Gd3+/Yb3+/Er3+ co-doped NaYF4 nanophosphors for multimodality PET/MR/UCL imaging.

    PubMed

    Zhou, Jing; Yu, Mengxiao; Sun, Yun; Zhang, Xianzhong; Zhu, Xingjun; Wu, Zhanhong; Wu, Dongmei; Li, Fuyou

    2011-02-01

    Molecular imaging modalities provide a wealth of information that is highly complementary and rarely redundant. To combine the advantages of molecular imaging techniques, (18)F-labeled Gd(3+)/Yb(3+)/Er(3+) co-doped NaYF(4) nanophosphors (NPs) simultaneously possessing with radioactivity, magnetic, and upconversion luminescent properties have been fabricated for multimodality positron emission tomography (PET), magnetic resonance imaging (MRI), and laser scanning upconversion luminescence (UCL) imaging. Hydrophilic citrate-capped NaY(0.2)Gd(0.6)Yb(0.18)Er(0.02)F(4) nanophosphors (cit-NPs) were obtained from hydrophobic oleic acid (OA)-coated nanoparticles (OA-NPs) through a process of ligand exchange of OA with citrate, and were found to be monodisperse with an average size of 22 × 19 nm. The obtained hexagonal cit-NPs show intense UCL emission in the visible region and paramagnetic longitudinal relaxivity (r(1) = 0.405 s(-1)·(mM)(-1)). Through a facile inorganic reaction based on the strong binding between Y(3+) and F(-), (18)F-labeled NPs have been fabricated in high yield. The use of cit-NPs as a multimodal probe has been further explored for T(1)-weighted MR and PET imaging in vivo and UCL imaging of living cells and tissue slides. The results indicate that (18)F-labeled NaY(0.2)Gd(0.6)Yb(0.18)Er(0.02) is a potential candidate as a multimodal nanoprobe for ultra-sensitive molecular imaging from the cellular scale to whole-body evaluation. Copyright © 2010 Elsevier Ltd. All rights reserved.

  14. In vivo spatial correlation between (18)F-BPA and (18)F-FDG uptakes in head and neck cancer.

    PubMed

    Kobayashi, Kazuma; Kurihara, Hiroaki; Watanabe, Yoshiaki; Murakami, Naoya; Inaba, Koji; Nakamura, Satoshi; Wakita, Akihisa; Okamoto, Hiroyuki; Umezawa, Rei; Takahashi, Kana; Igaki, Hiroshi; Ito, Yoshinori; Yoshimoto, Seiichi; Shigematsu, Naoyuki; Itami, Jun

    2016-09-01

    Borono-2-(18)F-fluoro-phenylalanine ((18)F-BPA) has been used to estimate the therapeutic effects of boron neutron capture therapy (BNCT), while (18)F-fluorodeoxyglucose ((18)F-FDG) is the most commonly used positron emission tomography (PET) radiopharmaceutical in a routine clinical use. The aim of the present study was to evaluate spatial correlation between (18)F-BPA and (18)F-FDG uptakes using a deformable image registration-based technique. Ten patients with head and neck cancer were recruited from January 2014 to December 2014. All patients underwent whole-body (18)F-BPA PET/computed tomography (CT) and (18)F-FDG PET/CT within a 2-week period. For each patient, (18)F-BPA PET/CT and (18)F-FDG PET/CT images were aligned based on a deformable image registration framework. The voxel-by-voxel spatial correlation of standardized uptake value (SUV) within the tumor was analyzed. Our image processing framework achieved accurate and validated registration results for each PET/CT image. In 9/10 patients, the spatial distribution of SUVs between (18)F-BPA and (18)F-FDG showed a significant, positive correlation in the tumor volume. Deformable image registration-based voxel-wise analysis demonstrated a spatial correlation between (18)F-BPA and (18)F-FDG uptakes in the head and neck cancer. A tumor sub-volume with a high (18)F-FDG uptake may predict high accumulation of (18)F-BPA. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  15. Positron emission tomography (PET) imaging with 18F-based radiotracers

    PubMed Central

    Alauddin, Mian M

    2012-01-01

    Positron Emission Tomography (PET) is a nuclear medicine imaging technique that is widely used in early detection and treatment follow up of many diseases, including cancer. This modality requires positron-emitting isotope labeled biomolecules, which are synthesized prior to perform imaging studies. Fluorine-18 is one of the several isotopes of fluorine that is routinely used in radiolabeling of biomolecules for PET; because of its positron emitting property and favorable half-life of 109.8 min. The biologically active molecule most commonly used for PET is 2-deoxy-2-18F-fluoro-β-D-glucose (18F-FDG), an analogue of glucose, for early detection of tumors. The concentrations of tracer accumulation (PET image) demonstrate the metabolic activity of tissues in terms of regional glucose metabolism and accumulation. Other tracers are also used in PET to image the tissue concentration. In this review, information on fluorination and radiofluorination reactions, radiofluorinating agents, and radiolabeling of various compounds and their application in PET imaging is presented. PMID:23133802

  16. Development of [18F]DASA-23 for Imaging Tumor Glycolysis Through Noninvasive Measurement of Pyruvate Kinase M2.

    PubMed

    Beinat, Corinne; Alam, Israt S; James, Michelle L; Srinivasan, Ananth; Gambhir, Sanjiv Sam

    2017-10-01

    A hallmark of cancer is metabolic reprogramming, which is exploited by cancer cells to ensure rapid growth and survival. Pyruvate kinase M2 (PKM2) catalyzes the final step in glycolysis, a key step in tumor metabolism and growth. Recently, we reported the radiosynthesis of the first positron emission tomography tracer for visualizing PKM2 in vivo-i.e., [ 11 C]DASA-23. Due to the highly promising imaging results obtained with [ 11 C]DASA-23 in rodent model glioblastoma, we set out to generate an F-18-labeled version of this tracer, with the end goal of clinical translation in mind. Herein, we report the radiosynthesis of 1-((2-fluoro-6-[ 18 F]fluorophenyl)sulfonyl)-4-((4-methoxyphenyl)sulfonyl)piperazine ([ 18 F]DASA-23) and our initial investigation of its binding properties in cancer cells. We synthesized [ 18 F]DASA-23 via fluorination of 1-((2-fluoro-6-nitrophenyl)sulfonyl)-4-((4-methoxyphenyl)sulfonyl)piperazine (10) with K[ 18 F]F/K2.2.2 in N,N-dimethylformamide at 110 °C for 20 min. Subsequently, we evaluated uptake of [ 18 F]DASA-23 in HeLa cervical adenocarcinoma cells and in vitro stability in human and mouse serum. We successfully prepared [ 18 F]DASA-23 in 2.61 ± 1.54 % radiochemical yield (n = 10, non-decay corrected at end of synthesis) with a specific activity of 2.59 ± 0.44 Ci/μmol. Preliminary cell uptake experiments revealed high uptake in HeLa cells, which was effectively blocked by pretreating cells with the structurally distinct PKM2 activator, TEPP-46. [ 18 F]DASA-23 remained intact in human and mouse serum up to 120 min. Herein, we have identified a F-18-labeled PKM2 specific radiotracer which shows potential for in vivo imaging. The promising cell uptake results reported herein warrant the further evaluation of [ 18 F]DASA-23 for its ability to detect and monitor cancer noninvasively.

  17. Automated production of [18 F]FTHA according to GMP.

    PubMed

    Savisto, Nina; Viljanen, Tapio; Kokkomäki, Esa; Bergman, Jörgen; Solin, Olof

    2018-02-01

    14-(R,S)-[ 18 F]fluoro-6-thia-heptadecanoic acid is a tracer for fatty acid imaging by positron emission tomography. High demand for this tracer required us to replace semiautomatic synthesis with a fully automated procedure. An automated synthesis device was constructed in-house for multistep nucleophilic 18 F-fluorination and a control system was developed. The synthesis device was combined with a sterile filtration unit and both were qualified. 14-(R,S)-[ 18 F]fluoro-6-thia-heptadecanoic acid was produced according to good manufacturing practice guidelines set by the European Union. The synthesis includes an initial nucleophilic labelling reaction, deprotection, preparative HPLC separation, purification of the final product, and formulation for injection. The duration and temperature of the reaction and hydrolysis were optimized, and the radiochemical stability of the formulated product was determined. The rotary evaporator used to evaporate the solvent after HPLC purification was replaced with solid phase extraction purification. We also replaced the human serum albumin used in the earlier procedure with a phosphate buffer-ascorbic acid mixture in the final formulation solution. From 2011 to 2016, we performed 219 synthesis procedures, 94% of which were successful. The radiochemical yield of 14-(R,S)-[ 18 F]fluoro-6-thia-heptadecanoic acid, decay-corrected to the end of bombardment, was 13% ± 6.3%. The total amount of formulated end product was 1.7 ± 0.8 GBq at end of synthesis. Copyright © 2017 John Wiley & Sons, Ltd.

  18. Subcellular storage and release mode of the novel 18F-labeled sympathetic nerve PET tracer LMI1195.

    PubMed

    Chen, Xinyu; Werner, Rudolf A; Lapa, Constantin; Nose, Naoko; Hirano, Mitsuru; Javadi, Mehrbod S; Robinson, Simon; Higuchi, Takahiro

    2018-02-06

    18 F-N-[3-bromo-4-(3-fluoro-propoxy)-benzyl]-guanidine ( 18 F-LMI1195) is a new class of PET tracer designed for sympathetic nervous imaging of the heart. The favorable image quality with high and specific neural uptake has been previously demonstrated in animals and humans, but intracellular behavior is not yet fully understood. The aim of the present study is to verify whether it is taken up in storage vesicles and released in company with vesicle turnover. Both vesicle-rich (PC12) and vesicle-poor (SK-N-SH) norepinephrine-expressing cell lines were used for in vitro tracer uptake studies. After 2 h of 18 F-LMI1195 preloading into both cell lines, effects of stimulants for storage vesicle turnover (high concentration KCl (100 mM) or reserpine treatment) were measured at 10, 20, and 30 min. 131 I-meta-iodobenzylguanidine ( 131 I-MIBG) served as a reference. Both high concentration KCl and reserpine enhanced 18 F-LMI1195 washout from PC12 cells, while tracer retention remained stable in the SK-N-SH cells. After 30 min of treatment, 18 F-LMI1195 releasing index (percentage of tracer released from cells) from vesicle-rich PC12 cells achieved significant differences compared to cells without treatment condition. In contrast, such effect could not be observed using vesicle-poor SK-N-SH cell lines. Similar tracer kinetics after KCl or reserpine treatment were also observed using 131 I-MIBG. In case of KCl exposure, Ca 2 +-free buffer with the calcium chelator, ethylenediaminetetracetic acid (EDTA), could suppress the tracer washout from PC12 cells. This finding is consistent with the tracer release being mediated by Ca 2 + influx resulting from membrane depolarization. Analogous to 131 I-MIBG, the current in vitro tracer uptake study confirmed that 18 F-LMI1195 is also stored in vesicles in PC12 cells and released along with vesicle turnover. Understanding the basic kinetics of 18 F-LMI1195 at a subcellular level is important for the design of clinical imaging protocols

  19. Use of Flutemetamol F 18-Labeled Positron Emission Tomography and Other Biomarkers to Assess Risk of Clinical Progression in Patients With Amnestic Mild Cognitive Impairment.

    PubMed

    Wolk, David A; Sadowsky, Carl; Safirstein, Beth; Rinne, Juha O; Duara, Ranjan; Perry, Richard; Agronin, Marc; Gamez, Jose; Shi, Jiong; Ivanoiu, Adrian; Minthon, Lennart; Walker, Zuzana; Hasselbalch, Steen; Holmes, Clive; Sabbagh, Marwan; Albert, Marilyn; Fleisher, Adam; Loughlin, Paul; Triau, Eric; Frey, Kirk; Høgh, Peter; Bozoki, Andrea; Bullock, Roger; Salmon, Eric; Farrar, Gillian; Buckley, Christopher J; Zanette, Michelle; Sherwin, Paul F; Cherubini, Andrea; Inglis, Fraser

    2018-05-14

    Patients with amnestic mild cognitive impairment (aMCI) may progress to clinical Alzheimer disease (AD), remain stable, or revert to normal. Earlier progression to AD among patients who were β-amyloid positive vs those who were β-amyloid negative has been previously observed. Current research now accepts that a combination of biomarkers could provide greater refinement in the assessment of risk for clinical progression. To evaluate the ability of flutemetamol F 18 and other biomarkers to assess the risk of progression from aMCI to probable AD. In this multicenter cohort study, from November 11, 2009, to January 16, 2014, patients with aMCI underwent positron emission tomography (PET) at baseline followed by local clinical assessments every 6 months for up to 3 years. Patients with aMCI (365 screened; 232 were eligible) were recruited from 28 clinical centers in Europe and the United States. Physicians remained strictly blinded to the results of PET, and the standard of truth was an independent clinical adjudication committee that confirmed or refuted local assessments. Flutemetamol F 18-labeled PET scans were read centrally as either negative or positive by 5 blinded readers with no knowledge of clinical status. Statistical analysis was conducted from February 19, 2014, to January 26, 2018. Flutemetamol F 18-labeled PET at baseline followed by up to 6 clinical visits every 6 months, as well as magnetic resonance imaging and multiple cognitive measures. Time from PET to probable AD or last follow-up was plotted as a Kaplan-Meier survival curve; PET scan results, age, hippocampal volume, and aMCI stage were entered into Cox proportional hazards logistic regression analyses to identify variables associated with progression to probable AD. Of 232 patients with aMCI (118 women and 114 men; mean [SD] age, 71.1 [8.6] years), 98 (42.2%) had positive results detected on PET scan. By 36 months, the rates of progression to probable AD were 36.2% overall (81 of 224 patients

  20. Optical reaction cell and light source for [18F] fluoride radiotracer synthesis

    DOEpatents

    Ferrieri, R.A.; Schlyer, D.; Becker, R.J.

    1998-09-15

    An apparatus is disclosed for performing organic synthetic reactions, particularly no-carrier-added nucleophilic radiofluorination reactions for PET radiotracer production. The apparatus includes an optical reaction cell and a source of broadband infrared radiant energy, which permits direct coupling of the emitted radiant energy with the reaction medium to heat the reaction medium. Preferably, the apparatus includes means for focusing the emitted radiant energy into the reaction cell, and the reaction cell itself is preferably configured to reflect transmitted radiant energy back into the reaction medium to further improve the efficiency of the apparatus. The apparatus is well suited to the production of high-yield syntheses of 2-[{sup 18}F]fluoro-2-deoxy-Dglucose. Also provided is a method for performing organic synthetic reactions, including the manufacture of [{sup 18}F]-labeled compounds useful as PET radiotracers, and particularly for the preparation of 2-[{sup 18}F]fluoro-2-deoxy-D-glucose in higher yields than previously possible. 4 figs.

  1. Affimer proteins for F-actin: novel affinity reagents that label F-actin in live and fixed cells.

    PubMed

    Lopata, Anna; Hughes, Ruth; Tiede, Christian; Heissler, Sarah M; Sellers, James R; Knight, Peter J; Tomlinson, Darren; Peckham, Michelle

    2018-04-26

    Imaging the actin cytoskeleton in cells uses a wide range of approaches. Typically, a fluorescent derivative of the small cyclic peptide phalloidin is used to image F-actin in fixed cells. Lifeact and F-tractin are popular for imaging the cytoskeleton in live cells. Here we characterised novel affinity reagents called Affimers that specifically bind to F-actin in vitro to determine if they are suitable alternatives as eGFP-fusion proteins, to label actin in live cells, or for labeling F-actin in fixed cells. In vitro experiments showed that 3 out of the 4 Affimers (Affimers 6, 14 and 24) tested bind tightly to purified F-actin, and appear to have overlapping binding sites. As eGFP-fusion proteins, the same 3 Affimers label F-actin in live cells. FRAP experiments suggest that eGFP-Affimer 6 behaves most similarly to F-tractin and Lifeact. However, it does not colocalise with mCherry-actin in dynamic ruffles, and may preferentially bind stable actin filaments. All 4 Affimers label F-actin in methanol fixed cells, while only Affimer 14 labels F-actin after paraformaldehyde fixation. eGFP-Affimer 6 has potential for use in selectively imaging the stable actin cytoskeleton in live cells, while all 4 Affimers are strong alternatives to phalloidin for labelling F-actin in fixed cells.

  2. Synthesis of carbon-11, fluorine-18, and nitrogen-13 labeled radiotracers for biomedical applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fowler, J.S.; Wolf, A.P.

    A number of reviews, many of them recent, have appeared on various aspects of /sup 11/C, /sup 18/F and /sup 13/N-labeled radiotracers. This monograph treats the topic principally from the standpoint of synthetic organic chemistry while keeping in perspective the necessity of integrating the organic chemistry with the design and ultimate application of the radiotracer. Where possible, recent examples from the literature of organic synthesis are introduced to suggest potentially new routes which may be applied to problems in labeling organic molecules with the short-lived positron emitters, carbon-11, fluorine-18, and nitrogen-13. The literature survey of carbon-11, fluorine-18 and nitrogen-13 labeledmore » compounds presented are of particular value to scientists working in this field. Two appendices are also included to provide supplementary general references. A subject index concludes this volume.« less

  3. A Dual Tracer 18F-FCH/18F-FDG PET Imaging of an Orthotopic Brain Tumor Xenograft Model.

    PubMed

    Fu, Yilong; Ong, Lai-Chun; Ranganath, Sudhir H; Zheng, Lin; Kee, Irene; Zhan, Wenbo; Yu, Sidney; Chow, Pierce K H; Wang, Chi-Hwa

    2016-01-01

    Early diagnosis of low grade glioma has been a challenge to clinicians. Positron Emission Tomography (PET) using 18F-FDG as a radio-tracer has limited utility in this area because of the high background in normal brain tissue. Other radiotracers such as 18F-Fluorocholine (18F-FCH) could provide better contrast between tumor and normal brain tissue but with high incidence of false positives. In this study, the potential application of a dual tracer 18F-FCH/18F-FDG-PET is investigated in order to improve the sensitivity of PET imaging for low grade glioma diagnosis based on a mouse orthotopic xenograft model. BALB/c nude mice with and without orthotopic glioma xenografts from U87 MG-luc2 glioma cell line are used for the study. The animals are subjected to 18F-FCH and 18F-FDG PET imaging, and images acquired from two separate scans are superimposed for analysis. The 18F-FCH counts are subtracted from the merged images to identify the tumor. Micro-CT, bioluminescence imaging (BLI), histology and measurement of the tumor diameter are also conducted for comparison. Results show that there is a significant contrast in 18F-FCH uptake between tumor and normal brain tissue (2.65 ± 0.98), but with a high false positive rate of 28.6%. The difficulty of identifying the tumor by 18F-FDG only is also proved in this study. All the tumors can be detected based on the dual tracer technique of 18F-FCH/18F-FDG-PET imaging in this study, while the false-positive caused by 18F-FCH can be eliminated. Dual tracer 18F-FCH/18F-FDG PET imaging has the potential to improve the visualization of low grade glioma. 18F-FCH delineates tumor areas and the tumor can be identified by subtracting the 18F-FCH counts. The sensitivity was over 95%. Further studies are required to evaluate the possibility of applying this technique in clinical trials.

  4. A Dual Tracer 18F-FCH/18F-FDG PET Imaging of an Orthotopic Brain Tumor Xenograft Model

    PubMed Central

    Ranganath, Sudhir H.; Zheng, Lin; Kee, Irene; Zhan, Wenbo; Yu, Sidney; Chow, Pierce K. H.; Wang, Chi-Hwa

    2016-01-01

    Early diagnosis of low grade glioma has been a challenge to clinicians. Positron Emission Tomography (PET) using 18F-FDG as a radio-tracer has limited utility in this area because of the high background in normal brain tissue. Other radiotracers such as 18F-Fluorocholine (18F-FCH) could provide better contrast between tumor and normal brain tissue but with high incidence of false positives. In this study, the potential application of a dual tracer 18F-FCH/18F-FDG-PET is investigated in order to improve the sensitivity of PET imaging for low grade glioma diagnosis based on a mouse orthotopic xenograft model. BALB/c nude mice with and without orthotopic glioma xenografts from U87 MG-luc2 glioma cell line are used for the study. The animals are subjected to 18F-FCH and 18F-FDG PET imaging, and images acquired from two separate scans are superimposed for analysis. The 18F-FCH counts are subtracted from the merged images to identify the tumor. Micro-CT, bioluminescence imaging (BLI), histology and measurement of the tumor diameter are also conducted for comparison. Results show that there is a significant contrast in 18F-FCH uptake between tumor and normal brain tissue (2.65 ± 0.98), but with a high false positive rate of 28.6%. The difficulty of identifying the tumor by 18F-FDG only is also proved in this study. All the tumors can be detected based on the dual tracer technique of 18F-FCH/ 18F-FDG-PET imaging in this study, while the false-positive caused by 18F-FCH can be eliminated. Dual tracer 18F-FCH/18F-FDG PET imaging has the potential to improve the visualization of low grade glioma. 18F-FCH delineates tumor areas and the tumor can be identified by subtracting the 18F-FCH counts. The sensitivity was over 95%. Further studies are required to evaluate the possibility of applying this technique in clinical trials. PMID:26844770

  5. Cu-mediated C–H 18F-fluorination of electron-rich (hetero)arenes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCammant, Matthew S.; Thompson, Stephen; Brooks, Allen F.

    This communication describes a method for the nucleophilic radiofluorination of electron-rich arenes. The reaction involves the initial C(sp 2)–H functionalization of an electron-rich arene with MesI(OH)OTs to form a (mesityl)(aryl)iodonium salt. This salt is then used in situ in a Cu-mediated radiofluorination with [ 18F]KF. This approach leverages the stability and availability of electron-rich arene starting materials to enable mild late-stage radiofluorination of toluene, anisole, aniline, pyrrole, and thiophene derivatives. Finally, the radiofluorination has been automated to access a 41 mCi dose of an 18F-labeled nimesulide derivative in high (2800 ± 700 Ci/mmol) specific activity.

  6. Cu-mediated C–H 18F-fluorination of electron-rich (hetero)arenes

    DOE PAGES

    McCammant, Matthew S.; Thompson, Stephen; Brooks, Allen F.; ...

    2017-06-30

    This communication describes a method for the nucleophilic radiofluorination of electron-rich arenes. The reaction involves the initial C(sp 2)–H functionalization of an electron-rich arene with MesI(OH)OTs to form a (mesityl)(aryl)iodonium salt. This salt is then used in situ in a Cu-mediated radiofluorination with [ 18F]KF. This approach leverages the stability and availability of electron-rich arene starting materials to enable mild late-stage radiofluorination of toluene, anisole, aniline, pyrrole, and thiophene derivatives. Finally, the radiofluorination has been automated to access a 41 mCi dose of an 18F-labeled nimesulide derivative in high (2800 ± 700 Ci/mmol) specific activity.

  7. 76 FR 37129 - Determination That SODIUM FLUORIDE F 18 (Sodium Fluoride F-18) Injection, 10 to 200 Millicuries...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-24

    ...] Determination That SODIUM FLUORIDE F 18 (Sodium Fluoride F-18) Injection, 10 to 200 Millicuries per Milliliter... FLUORIDE F 18 (sodium fluoride F-18) injection, 10 to 200 millicuries per milliliter (mCi/mL), was not... abbreviated new drug applications (ANDAs) for SODIUM FLUORIDE F 18 injection, 10 to 200 mCi/mL, if all other...

  8. Synthesis and biological evaluation of ¹⁸F-labeled fluoropropyl tryptophan analogs as potential PET probes for tumor imaging.

    PubMed

    Chiotellis, Aristeidis; Mu, Linjing; Müller, Adrienne; Selivanova, Svetlana V; Keller, Claudia; Schibli, Roger; Krämer, Stefanie D; Ametamey, Simon M

    2013-01-01

    In the search for an efficient, fluorine-18 labeled amino acid based radiotracer for tumor imaging with positron emission tomography (PET), two new tryptophan analogs were synthesized and characterized in vitro and in vivo. Both are tryptophan alkyl-derivatives, namely 2-(3-[(18)F]fluoropropyl)-DL-tryptophan ([(18)F]2-FPTRP) and 5-(3-[(18)F]fluoro-propyl)-DL-tryptophan ([(18)F]5-FPTRP). Standard reference compounds and precursors were prepared by multi step approaches. Radiosynthesis was achieved by no-carrier-added nucleophilic [(18)F]fluorination in 29-34% decay corrected yields with radiochemical purity over 99%. In vitro cell uptake assays showed that both compounds are substrates for amino acid transport and enter small cell lung cancer cells (NCI-H69) most probably almost exclusively via large neutral amino acids transporter(s) (LAT). Small animal PET imaging with xenograft bearing mice revealed high tumor/background ratios for [(18)F]2-FPTRP comparable to the well established tyrosine analog O-(2-[(18)F]fluroethyl)-L-tyrosine ([(18)F]FET). Radiometabolite studies showed no evidence of involvement of a biotransformation step in tumor accumulation. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  9. Radiolabeling of multimeric neurotensin(8-13) analogs with the short-lived positron emitter fluorine-18.

    PubMed

    Hultsch, Christina; Berndt, Mathias; Bergmann, Ralf; Wuest, Frank

    2007-07-01

    Three methods for (18)F-labeling of dimeric and tetrameric neurotensin(8-13) derivatives were evaluated with respect to the labeling yield and the required peptide amounts. Labeling using N-succinimidyl-4-[(18)F]fluorobenzoate ([(18)F]SFB) gave low radiochemical yield for the dimeric peptides. Coupling of the tetramer with [(18)F]SFB was not successful. High yields were obtained for labeling of the aminooxy-functionalized neurotensin(8-13) dimer using 4-[(18)F]fluorobenzaldehyde ([(18)F]FBA) whilst coupling of the corresponding tetramer gave only low yields. Labeling of sulfydryl-functionalized neurotensin(8-13) derivatives using the maleinimide 4-[(18)F]fluorobenzaldehyde-O-[6-(2,5-dioxo-2,5-dihydro-pyrrol-1-yl)-hexyl]-oxime ([(18)F]FBAM) resulted in high radiochemical yields for both, the dimer and the tetramer. Therefore, [(18)F]FBAM seems to be the most suitable (18)F-labeling agent for multivalent neurotensin(8-13) derivatives.

  10. [Simplicity or complexity of the radiopharmaceutical production process in the light of optimization of radiation protection of staff - 99mTc vs. 18F].

    PubMed

    Wrzesień, Małgorzata

    2018-05-22

    A radiopharmaceutical is a combination of a non-radioactive compound with a radioactive isotope. Two isotopes: technetium-99m (99mTc) and fluorine-18 (18F) are worth mentioning on the rich list of isotopes which have found numerous medical applications. Their similarity is limited only to the diagnostic area of applicability. The type and the energy of emitted radiation, the half-life and, in particular, the production method demonstrate their diversity. The 99mTc isotope is produced by a short-lived nuclide generator - molybdenum-99 (99Mo)/99mTc, while 18F is resulting from nuclear reaction occurring in a cyclotron. A relatively simple and easy handling of the 99Mo/99mTc generator, compared to the necessary use a cyclotron, seems to favor the principle of optimizing the radiological protection of personnel. The thesis on the effect of automation of both the 18F isotope production and the deoxyglucose labelling process on the optimization of radiological protection of workers compared to manual procedures during handling of radiopharmaceuticals labelled with 99Tc need to be verified. Measurements of personal dose equivalent Hp(0.07) were made in 5 nuclear medicine departments and 2 radiopharmaceuticals production centers. High-sensitivity thermoluminescent detectors (LiF: Mg, Cu, P - MCP-N) were used to determine the doses. Among the activities performed by employees of both 18F-fluorodeoxyglucose (18F-FDG) production centers and nuclear medicine departments, the manual quality control procedures and labelling of radiopharmaceuticals with 99mTc isotope manifest the greatest contribution to the recorded Hp(0.07). The simplicity of obtaining the 99mTc isotope as well as the complex, but fully automated production process of the 18F-FDG radiopharmaceutical optimize the radiation protection of workers, excluding manual procedures labelling with 99mTc or quality control of 18F-FDG. Med Pr 2018;69(3):317–327. This work is available in Open Access model and licensed

  11. A Novel Method for Relative Quantitation of N-Glycans by Isotopic Labeling Using 18O-Water

    PubMed Central

    Tao, Shujuan; Orlando, Ron

    2014-01-01

    Quantitation is an essential aspect of comprehensive glycomics study. Here, a novel isotopic-labeling method is described for N-glycan quantitation using 18O-water. The incorporation of the 18O-labeling into the reducing end of N-glycans is simply and efficiently achieved during peptide-N4-(N-acetyl-β-glucosaminyl) asparagine amidase F release. This process provides a 2-Da mass difference compared with the N-glycans released in 16O-water. A mathematical calculation method was also developed to determine the 18O/16O ratios from isotopic peaks. Application of this method to several standard glycoprotein mixtures and human serum demonstrated that this method can facilitate the relative quantitation of N-glycans over a linear dynamic range of two orders, with high accuracy and reproducibility. PMID:25365792

  12. Synthesis, enantiomeric resolution, F-18 labeling and biodistribution of reboxetine analogs: promising radioligands for imaging the norepinephrine transporter with positron emission tomography.

    PubMed

    Lin, Kuo-Shyan; Ding, Yu-Shin; Kim, Sung-Won; Kil, Kun-Eek

    2005-05-01

    Racemic and enantiomerically pure ((S,S) and (R,R)) 2-[alpha-(2-(2-[(18)F]fluoroethoxy)phenoxy)benzyl]morpholine ([(18)F]FRB) and its tetradeuterated form [(18)F]FRB-D(4), analogs of the highly selective norepinephrine reuptake inhibitor reboxetine (2-[alpha-(2-ethoxyphenoxy)benzyl]morpholine, RB), have been synthesized for studies of norepinephrine transporter (NET) system with positron emission tomography (PET). The [(18)F]fluorinated precursor, (S,S)/(R,R)-N-tert-butyloxycarbonyl-2-[alpha-(2-hydroxyphenoxy)benzyl]morpholine ((S,S)/(R,R)-N-Boc-desethylRB), was prepared by the N-protection of (S,S)/(R,R)-2-[alpha-(2-hydroxyphenoxy)benzyl]morpholine ((S,S)/(R,R)-desethylRB) with a tert-butyloxycarbonyl (Boc) group followed by enantiomeric resolution with chiral HPLC to provide both (S,S) and (R,R) enantiomers with >99% enantiomeric purity. These compounds were then used for radiosynthesis to prepare enantiomerically pure [(18)F]FRB and [(18)F]FRB-D(4) via the following three-step procedure: (1) formation of 1-bromo-2-[(18)F]fluoroethane ([(18)F]BFE or [(18)F]BFE-D(4)) by nucleophilic displacement of 2-bromoethyl triflate (or D(4) analog) with no-carrier added [(18)F]F(-) in THF; (2) reaction of [(18)F]BFE (or [(18)F]BFE-D(4)) with N-Boc-desethylRB in DMF in the presence of excess base; and (3) deprotection with trifluoroacetic acid. The racemates, (S,S) and (R,R) enantiomers of [(18)F]FRB and [(18)F]FRB-D(4) were obtained in 11-27% (decay corrected to the end of bombardment, EOB) in 120-min synthesis time with a radiochemical purity of >98% and specific activities of 21-48 GBq/micromol (EOB). The results of the whole-body biodistribution studies with (S,S)-[(18)F]FRB-D(4) were similar to those with (S,S)-[(18)F]FRB but showed relatively faster blood clearance and no significant in vivo defluorination. Positron emission tomography studies in baboon brain also showed that (S,S)-[(18)F]FRB-D(4) may be a potentially useful ligand for imaging NET with PET.

  13. A Comparative Study of the Hypoxia PET Tracers [{sup 18}F]HX4, [{sup 18}F]FAZA, and [{sup 18}F]FMISO in a Preclinical Tumor Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peeters, Sarah G.J.A., E-mail: sarah.peeters@maastrichtuniversity.nl; Zegers, Catharina M.L.; Lieuwes, Natasja G.

    Purpose: Several individual clinical and preclinical studies have shown the possibility of evaluating tumor hypoxia by using noninvasive positron emission tomography (PET). The current study compared 3 hypoxia PET tracers frequently used in the clinic, [{sup 18}F]FMISO, [{sup 18}F]FAZA, and [{sup 18}F]HX4, in a preclinical tumor model. Tracer uptake was evaluated for the optimal time point for imaging, tumor-to-blood ratios (TBR), spatial reproducibility, and sensitivity to oxygen modification. Methods and Materials: PET/computed tomography (CT) images of rhabdomyosarcoma R1-bearing WAG/Rij rats were acquired at multiple time points post injection (p.i.) with one of the hypoxia tracers. TBR values were calculated, andmore » reproducibility was investigated by voxel-to-voxel analysis, represented as correlation coefficients (R) or Dice similarity coefficient of the high-uptake volume. Tumor oxygen modifications were induced by exposure to either carbogen/nicotinamide treatment or 7% oxygen breathing. Results: TBR was stabilized and maximal at 2 hours p.i. for [{sup 18}F]FAZA (4.0 ± 0.5) and at 3 hours p.i. for [{sup 18}F]HX4 (7.2 ± 0.7), whereas [{sup 18}F]FMISO showed a constant increasing TBR (9.0 ± 0.8 at 6 hours p.i.). High spatial reproducibility was observed by voxel-to-voxel comparisons and Dice similarity coefficient calculations on the 30% highest uptake volume for both [{sup 18}F]FMISO (R = 0.86; Dice coefficient = 0.76) and [{sup 18}F]HX4 (R = 0.76; Dice coefficient = 0.70), whereas [{sup 18}F]FAZA was less reproducible (R = 0.52; Dice coefficient = 0.49). Modifying the hypoxic fraction resulted in enhanced mean standardized uptake values for both [{sup 18}F]HX4 and [{sup 18}F]FAZA upon 7% oxygen breathing. Only [{sup 18}F]FMISO uptake was found to be reversible upon exposure to nicotinamide and carbogen. Conclusions: This study indicates that each tracer has its own strengths and, depending on the question to be answered, a different tracer can be

  14. 5-(2-18F-fluoroethoxy)-L-tryptophan as a substrate of system L transport for tumor imaging by PET.

    PubMed

    Krämer, Stefanie D; Mu, Linjing; Müller, Adrienne; Keller, Claudia; Kuznetsova, Olga F; Schweinsberg, Christian; Franck, Dominic; Müller, Cristina; Ross, Tobias L; Schibli, Roger; Ametamey, Simon M

    2012-03-01

    Large neutral l-amino acids are substrates of system L amino acid transporters. The level of one of these, LAT1, is increased in many tumors. Aromatic l-amino acids may also be substrates of aromatic l-amino acid decarboxylase (AADC), the level of which is enhanced in endocrine tumors. Increased amino acid uptake and subsequent decarboxylation result in the intracellular accumulation of the amino acid and its decarboxylation product. (18)F- and (11)C-labeled neutral aromatic amino acids, such as l-3,4-dihydroxy-6-(18)F-fluorophenylalanine ((18)F-FDOPA) and 5-hydroxy-l-[β-(11)C]tryptophan, are thus successfully used in PET to image endocrine tumors. However, 5-hydroxy-l-[β-(11)C]tryptophan has a relatively short physical half-life (20 min). In this work, we evaluated the in vitro and in vivo characteristics of the (18)F-labeled tryptophan analog 5-(2-(18)F-fluoroethoxy)-l-tryptophan ((18)F-l-FEHTP) as a PET probe for tumor imaging. (18)F-l-FEHTP was synthesized by no-carrier-added (18)F fluorination of 5-hydroxy-l-tryptophan. In vitro cell uptake and efflux of (18)F-l-FEHTP and (18)F-FDOPA were studied with NCI-H69 endocrine small cell lung cancer cells, PC-3 pseudoendocrine prostate cancer cells, and MDA-MB-231 exocrine breast cancer cells. Small-animal PET was performed with the respective xenograft-bearing mice. Tissues were analyzed for potential metabolites. (18)F-l-FEHTP specific activity and radiochemical purity were 50-150 GBq/μmol and greater than 95%, respectively. In vitro cell uptake of (18)F-l-FEHTP was between 48% and 113% of added radioactivity per milligram of protein within 60 min at 37°C and was blocked by greater than 95% in all tested cell lines by the LAT1/2 inhibitor 2-amino-2-norboranecarboxylic acid. (18)F-FDOPA uptake ranged from 26% to 53%/mg. PET studies revealed similar xenograft-to-reference tissue ratios for (18)F-l-FEHTP and (18)F-FDOPA at 30-45 min after injection. In contrast to the (18)F-FDOPA PET results, pretreatment with the

  15. 18F-FDG PET/CT oncologic imaging at extended injection-to-scan acquisition time intervals derived from a single-institution 18F-FDG-directed surgery experience: feasibility and quantification of 18F-FDG accumulation within 18F-FDG-avid lesions and background tissues

    PubMed Central

    2014-01-01

    Background 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) is a well-established imaging modality for a wide variety of solid malignancies. Currently, only limited data exists regarding the utility of PET/CT imaging at very extended injection-to-scan acquisition times. The current retrospective data analysis assessed the feasibility and quantification of diagnostic 18F-FDG PET/CT oncologic imaging at extended injection-to-scan acquisition time intervals. Methods 18F-FDG-avid lesions (not surgically manipulated or altered during 18F-FDG-directed surgery, and visualized both on preoperative and postoperative 18F-FDG PET/CT imaging) and corresponding background tissues were assessed for 18F-FDG accumulation on same-day preoperative and postoperative 18F-FDG PET/CT imaging. Multiple patient variables and 18F-FDG-avid lesion variables were examined. Results For the 32 18F-FDG-avid lesions making up the final 18F-FDG-avid lesion data set (from among 7 patients), the mean injection-to-scan times of the preoperative and postoperative 18F-FDG PET/CT scans were 73 (±3, 70-78) and 530 (±79, 413-739) minutes, respectively (P < 0.001). The preoperative and postoperative mean 18F-FDG-avid lesion SUVmax values were 7.7 (±4.0, 3.6-19.5) and 11.3 (±6.0, 4.1-29.2), respectively (P < 0.001). The preoperative and postoperative mean background SUVmax values were 2.3 (±0.6, 1.0-3.2) and 2.1 (±0.6, 1.0-3.3), respectively (P = 0.017). The preoperative and postoperative mean lesion-to-background SUVmax ratios were 3.7 (±2.3, 1.5-9.8) and 5.8 (±3.6, 1.6-16.2), respectively, (P < 0.001). Conclusions 18F-FDG PET/CT oncologic imaging can be successfully performed at extended injection-to-scan acquisition time intervals of up to approximately 5 half-lives for 18F-FDG while maintaining good/adequate diagnostic image quality. The resultant increase in the 18F-FDG-avid lesion SUVmax values, decreased background SUVmax values, and

  16. {sup 18}F-desmethoxyfallypride: A fluorine-18 labeled radiotracer with properties similar to carbon-11 raclopride for PET imaging studies of dopamine D{sub 2} receptors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mukherjee, J.; Yang, Z.Y.; Brown, T.

    1996-07-19

    We have developed (S)-N-[(1-allyl-2-pyrrolidinyl)methyl]-5-(3-{sup 18}F-fluoropropyl)-2-methoxybenzamide ({sup 18}F-desmethoxyfallypride) as a fluorine-18 radiotracer with properties analogous to that of {sup 11}C-raclopride. In vitro experiments in rat brain homogenates showed an association rate constant of 2.1X10{sup 8} M{sup -1} min{sup -1} and a dissociation rate constant of 0.073 min{sup -1}. High striatal uptake (up to 0.08% injected dose/cc) of {sup 18}F-desmethoxyfallypride in rhesus monkeys was observed in PET experiments. The radiotracer cleared from the striata with a dissociation rate of 1.80X10{sup -2} min{sup -1}. Striatum to cerebellum ratios peaked at 3.0 in 30 min after which they decreased steadily. Intravenously administered haloperidol displacedmore » specifically bound {sup 18}F-desmethoxyfallypride with a k{sub off} of 0.058 min{sup -1}. Synaptic dopamine released by the treatment of the monkeys with a d-amphetamine increased the dissociation rate of {sup 18}F-desmethoxyfallypride to 0.83 min{sup -1} thus reducing specifically bound {sup 18}F-desmethoxyfallypride by 56% over a period of 42 mins compared to a reduction of only 20% in controls during this time period. The sensitivity of {sup 18}F-desmethoxyfallypride towards competition with dopamine should make this radiotracer useful in PET studies to evaluate in vivo pharmacological effects of various agents that alter levels of endogenous dopamine. 27 refs., 8 figs.« less

  17. Pharmacokinetics, metabolism, biodistribution, radiation dosimetry, and toxicology of (18)F-fluoroacetate ((18)F-FACE) in non-human primates.

    PubMed

    Nishii, Ryuichi; Tong, William; Wendt, Richard; Soghomonyan, Suren; Mukhopadhyay, Uday; Balatoni, Julius; Mawlawi, Osama; Bidaut, Luc; Tinkey, Peggy; Borne, Agatha; Alauddin, Mian; Gonzalez-Lepera, Carlos; Yang, Bijun; Gelovani, Juri G

    2012-04-01

    To facilitate the clinical translation of (18)F-fluoroacetate ((18)F-FACE), the pharmacokinetics, biodistribution, radiolabeled metabolites, radiation dosimetry, and pharmacological safety of diagnostic doses of (18)F-FACE were determined in non-human primates. (18)F-FACE was synthesized using a custom-built automated synthesis module. Six rhesus monkeys (three of each sex) were injected intravenously with (18)F-FACE (165.4 ± 28.5 MBq), followed by dynamic positron emission tomography (PET) imaging of the thoracoabdominal area during 0-30 min post-injection and static whole-body PET imaging at 40, 100, and 170 min. Serial blood samples and a urine sample were obtained from each animal to determine the time course of (18)F-FACE and its radiolabeled metabolites. Electrocardiograms and hematology analyses were obtained to evaluate the acute and delayed toxicity of diagnostic dosages of (18)F-FACE. The time-integrated activity coefficients for individual source organs and the whole body after administration of (18)F-FACE were obtained using quantitative analyses of dynamic and static PET images and were extrapolated to humans. The blood clearance of (18)F-FACE exhibited bi-exponential kinetics with half-times of 4 and 250 min for the fast and slow phases, respectively. A rapid accumulation of (18)F-FACE-derived radioactivity was observed in the liver and kidneys, followed by clearance of the radioactivity into the intestine and the urinary bladder. Radio-HPLC analyses of blood and urine samples demonstrated that (18)F-fluoride was the only detectable radiolabeled metabolite at the level of less than 9% of total radioactivity in blood at 180 min after the (18)F-FACE injection. The uptake of free (18)F-fluoride in the bones was insignificant during the course of the imaging studies. No significant changes in ECG, CBC, liver enzymes, or renal function were observed. The estimated effective dose for an adult human is 3.90-7.81 mSv from the administration of 185

  18. Synthesis, biological evaluation, and molecular dynamics (MD) simulation studies of three novel F-18 labeled and focal adhesion kinase (FAK) targeted 5-bromo pyrimidines as radiotracers for tumor.

    PubMed

    Fang, Yu; Wang, Dawei; Xu, Xingyu; Liu, Jianping; Wu, Aiqin; Li, Xiang; Xue, Qianqian; Wang, Huan; Wang, Hang; Zhang, Huabei

    2017-02-15

    Focal adhesion kinase (FAK) is considered as an attractive target for oncology. A series of F-18 labeled 5-bromo-N 2 -(4-(2-fluoro-pegylated (FPEG))-3,5-dimethoxyphenyl)-N 4 -(4-methoxyphenyl)pyrimidine-2,4-diamine derivatives were prepared and evaluated as the FAK targeted radiotracers for the early diagnoses of tumor. For the study of the FAK targeted drug molecules, this was the first attempt to develop the tumor diagnostic imaging agents on the radiopharmaceutical level. They inhibited the activity of FAK with IC 50 in the range of 91.4-425.7 nM, and among which the result of the [ 19 F]2 was relatively good and had a modest IC 50 of 91.4 nM. The [ 19 F]2 was also profiled in vitro against some other kinds of cancer-related kinases (including two kinds of non-receptor tyrosine kinase: PYK2 and JAK2, and three kinds of receptor tyrosine kinase: IGF-1R, EGFR and PDGFRβ). It displayed 25.2 folds selectivity against PYK2, 35.1 folds selectivity against EGFR, and more than 100 folds selectivity against IGF-1R, JAK2 and PDGFRβ. For the biodistribution in S180 bearing mice, the corresponding [ 18 F]2 were also relatively good, with modest tumor uptake of 5.47 ± 0.19 and 5.80 ± 0.06 %ID/g at 15 and 30 min post-injection, respectively. Furthermore, its tumor/muscle, tumor/bone and tumor/blood ratio at 15 min post-injection were 3.16, 2.53 and 4.52, respectively. And its tumor/muscle, tumor/bone and tumor/blood ratio at 30 min post-injection were 3.14, 2.76 and 4.43, respectively. In addition, coronal micro-PET/CT images of a mouse bearing S180 tumor clearly confirmed that [ 18 F]2 could be accumulated in tumor, especially at 30 min post-injection. Besides, for the [ 18 F]2, both the biodistribution data and the micro-PET/CT imaging study showed significantly reduced uptake of the radiotracer in the tumor tissue at 30 min post-injection in mice that received PF-562,271 (one of the reported best selective FAK inhibitor which was developed by Pfitzer Inc

  19. A fully-automated one-pot synthesis of [18F]fluoromethylcholine with reduced dimethylaminoethanol contamination via [18F]fluoromethyl tosylate.

    PubMed

    Rodnick, Melissa E; Brooks, Allen F; Hockley, Brian G; Henderson, Bradford D; Scott, Peter J H

    2013-08-01

    A novel one-pot method for preparing [(18)F]fluoromethylcholine ([(18)F]FCH) via in situ generation of [(18)F]fluoromethyl tosylate ([(18)F]FCH2OTs), and subsequent [(18)F]fluoromethylation of dimethylaminoethanol (DMAE), has been developed. [(18)F]FCH was prepared using a GE TRACERlab FXFN, although the method should be readily adaptable to any other fluorine-(18) synthesis module. Initially ditosylmethane was fluorinated to generate [(18)F]FCH2OTs. DMAE was then added and the reaction was heated at 120 °C for 10 min to generate [(18)F]FCH. After this time, reaction solvent was evaporated, and the crude reaction mixture was purified by solid-phase extraction using C(18)-Plus and CM-Light Sep-Pak cartridges to provide [(18)F]FCH formulated in USP saline. The formulated product was passed through a 0.22 µm filter into a sterile dose vial, and submitted for quality control testing. Total synthesis time was 1.25 h from end-of-bombardment. Typical non-decay-corrected yields of [(18)F]FCH prepared using this method were 91 mCi (7% non-decay corrected based upon ~1.3 Ci [(18)F]fluoride), and doses passed all other quality control (QC) tests. A one-pot liquid-phase synthesis of [(18)F]FCH has been developed. Doses contain extremely low levels of residual DMAE (31.6 µg/10 mL dose or ~3 ppm) and passed all other requisite QC testing, confirming their suitability for use in clinical imaging studies. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. A Fully-automated One-pot Synthesis of [18F]Fluoromethylcholine with Reduced Dimethylaminoethanol Contamination via [18F]Fluoromethyl Tosylate

    PubMed Central

    Rodnick, Melissa E.; Brooks, Allen F.; Hockley, Brian G.; Henderson, Bradford D.; Scott, Peter J. H.

    2013-01-01

    Introduction A novel one-pot method for preparing [18F]fluoromethylcholine ([18F]FCH) via in situ generation of [18F]fluoromethyl tosylate ([18F]FCH2OTs), and subsequent [18F]fluoromethylation of dimethylaminoethanol (DMAE), has been developed. Methods [18F]FCH was prepared using a GE TRACERlab FXFN, although the method should be readily adaptable to any other fluorine-18 synthesis module. Initially ditosylmethane was fluorinated to generate [18F]FCH2OTs. DMAE was then added and the reaction was heated at 120°C for 10 min to generate [18F]FCH. After this time, reaction solvent was evaporated, and the crude reaction mixture was purified by solid-phase extraction using C18-Plus and CM-Light Sep-Pak cartridges to provide [18F]FCH formulated in USP saline. The formulated product was passed through a 0.22 μm filter into a sterile dose vial, and submitted for quality control testing. Total synthesis time was 1.25 hours from end-of-bombardment. Results Typical non-decay-corrected yields of [18F]FCH prepared using this method were 91 mCi (7% non-decay corrected based upon ~1.3 Ci [18F]fluoride), and doses passed all other quality control (QC) tests. Conclusion A one-pot liquid-phase synthesis of [18F]FCH has been developed. Doses contain extremely low levels of residual DMAE (31.6 μg / 10 mL dose or ~3 ppm) and passed all other requisite QC testing, confirming their suitability for use in clinical imaging studies. PMID:23665261

  1. Automated cGMP-compliant radiosynthesis of [18 F]-(E)-PSS232 for brain PET imaging of metabotropic glutamate receptor subtype 5.

    PubMed

    Park, Jun Young; Son, Jeongmin; Yun, Mijin; Ametamey, Simon M; Chun, Joong-Hyun

    2018-01-01

    (E)-3-(Pyridin-2-yl ethynyl)cyclohex-2-enone O-(3-(2-[ 18 F]-fluoroethoxy)propyl) oxime ([ 18 F]-(E)-PSS232, [ 18 F]2a) is a recently developed radiotracer that can be used to visualize metabotropic glutamate receptor subtype 5 (mGlu 5 ) in vivo. The mGlu 5 has become an attractive therapeutic and diagnostic target owing to its role in many neuropsychiatric disorders. Several carbon-11-labeled and fluorine-18-labeled radiotracers have been developed to measure mGlu 5 receptor occupancy in the human brain. The radiotracer [ 18 F]2a, which is used as an analogue for [ 11 C]ABP688 ([ 11 C]1) and has a longer physical half-life, is a selective radiotracer that exhibits high binding affinity for mGlu 5 . Herein, we report the fully automated radiosynthesis of [ 18 F]2a using a commercial GE TRACERlab™ FX- FN synthesizer for routine production and distribution to nearby satellite clinics. Nucleophilic substitution of the corresponding mesylate precursor with cyclotron-produced [ 18 F]fluoride ion at 100°C in dimethyl sulfoxide (DMSO), followed by high-performance liquid chromatography (HPLC) purification and formulation, readily provided [ 18 F]2a with a radiochemical yield of 40 ± 2% (decay corrected, n = 5) at the end of synthesis. Radiochemical purity for the [ 18 F]-(E)-conformer was greater than 95%. Molar activity was determined to be 63.6 ± 9.6 GBq/μmol (n = 5), and the overall synthesis time was 70 minutes. Copyright © 2017 John Wiley & Sons, Ltd.

  2. Biodistribution and catabolism of 18F-labeled N-epsilon-fructoselysine as a model of Amadori products.

    PubMed

    Hultsch, Christina; Hellwig, Michael; Pawelke, Beate; Bergmann, Ralf; Rode, Katrin; Pietzsch, Jens; Krause, René; Henle, Thomas

    2006-10-01

    Amadori products are formed in the early stage of the so-called Maillard reaction between reducing sugars and amino acids or proteins. Such nonenzymatic glycosylation may occur during the heating or storage of foods, but also under physiological conditions. N-epsilon-fructoselysine is formed via this reaction between the epsilon-amino group of peptide-bound lysine and glucose. Despite the fact that, in certain heated foods, up to 50% of lysyl moieties may be modified to such lysine derivatives, up to now, very little is known about the metabolic fate of alimentary administered Amadori compounds. In the present study, N-succinimidyl-4-[18F]fluorobenzoate was used to modify N-epsilon-fructoselysine at the alpha-amino group of the lysyl moiety. The in vitro stability of the resulting 4-[18F]fluorobenzoylated derivative was tested in different tissue homogenates. Furthermore, the 4-[18F]fluorobenzoylated N-epsilon-fructoselysine was used in positron emission tomography studies, as well as in studies concerning biodistribution and catabolism. The results show that the 4-[18F]fluorobenzoylated N-epsilon-fructoselysine is phosphorylated in vitro, as well as in vivo. This phosphorylation is caused by fructosamine 3-kinases and occurs in vivo, particularly in the kidneys. Despite the action of these enzymes, it was shown that a large part of the intravenously applied radiolabeled N-epsilon-fructoselysine was excreted nearly unchanged in the urine. Therefore, it was concluded that the predominant part of peptide-bound lysine that was fructosylated during food processing is not available for nutrition.

  3. Synthetic, enzyme kinetic, and protein crystallographic studies of C-β-d-glucopyranosyl pyrroles and imidazoles reveal and explain low nanomolar inhibition of human liver glycogen phosphorylase.

    PubMed

    Kantsadi, Anastassia L; Bokor, Éva; Kun, Sándor; Stravodimos, George A; Chatzileontiadou, Demetra S M; Leonidas, Demetres D; Juhász-Tóth, Éva; Szakács, Andrea; Batta, Gyula; Docsa, Tibor; Gergely, Pál; Somsák, László

    2016-11-10

    C-β-d-Glucopyranosyl pyrrole derivatives were prepared in the reactions of pyrrole, 2-, and 3-aryl-pyrroles with O-peracetylated β-d-glucopyranosyl trichloroacetimidate, while 2-(β-d-glucopyranosyl) indole was obtained by a cross coupling of O-perbenzylated β-d-glucopyranosyl acetylene with N-tosyl-2-iodoaniline followed by spontaneous ring closure. An improved synthesis of O-perbenzoylated 2-(β-d-glucopyranosyl) imidazoles was achieved by reacting C-glucopyranosyl formimidates with α-aminoketones. The deprotected compounds were assayed with isoforms of glycogen phosphorylase (GP) to show no activity of the pyrroles against rabbit muscle GPb. The imidazoles proved to be the best known glucose derived inhibitors of not only the muscle enzymes (both a and b) but also of the pharmacologically relevant human liver GPa (Ki = 156 and 26 nM for the 4(5)-phenyl and -(2-naphthyl) derivatives, respectively). An X-ray crystallographic study of the rmGPb-imidazole complexes revealed structural features of the strong binding, and also allowed to explain the absence of inhibition for the pyrrole derivatives. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  4. TMSOTf assisted synthesis of 2'-deoxy-2'-[18F]fluoro-β-D-arabinofuranosylcytosine ([18F]FAC).

    PubMed

    Gangangari, Kishore K; Humm, John L; Larson, Steven M; Pillarsetty, Naga Vara Kishore

    2018-01-01

    [18F]FAC (2'-deoxy-2'-[18F]fluoro-β-D-arabinofuranosylcytosine, 1) is a versatile probe for imaging deoxycytidine kinase (dCK) expression levels in vivo. dCK is responsible for phosphorylation of deoxycytidine (dC, 2) and other nucleoside analogs, plays a key role in immune activation and has demonstrated to be one of the key enzymes in activating nucleoside based drugs including gemcitabine. Reported synthesis of [18F]FAC is high yielding but is quite challenging requiring bromination using HBr and careful drying of excess HBr which is critical for successful synthesis. Here in we report a simplified trimethylsilyl trifluoromethanesulfonate (TMSOTf) assisted synthesis of [18F]FAC eliminating the need of bromination and drying. [18F]FAC (β-anomer) was synthesized with average isolated decay corrected yield of 10.59 + 4.2% (n = 6) with radiochemical purity of >98% and total synthesis time of 158 + 19 min.

  5. False-positive 18F-fluorodeoxyglucose positron emission tomography/computed tomography in a patient with metallic implants following chondrosarcoma resection.

    PubMed

    Zhou, P U; Tang, Jinliang; Zhang, Dong; Li, Guanghui

    2016-05-01

    Positron emission tomography (PET) with fluorine-18-labeled fluorodeoxyglucose ( 18 F-FDG) has been used for the staging and evaluation of recurrence in cancer patients. We herein report a false-positive result of 18 F-FDG PET/computed tomography (CT) scan in a patient following chondrosarcoma resection and metallic implanting. A 35-year-old male patient with chondrosarcoma of the left iliac bone underwent radical resection, metal brace implanting and radiotherapy. A high uptake of 18 F-FDG was observed in the metallic implants and adjacent tissue during PET/CT scanning in the 5th year of follow-up. Tissue biopsy and follow-up examination identified no tumor recurrence or infection at these sites, suggesting that the results of 18 F-FDG PET/CT must be interpreted with caution in cancer patients with metallic implants.

  6. Thoracic staging in lung cancer: prospective comparison of 18F-FDG PET/MR imaging and 18F-FDG PET/CT.

    PubMed

    Heusch, Philipp; Buchbender, Christian; Köhler, Jens; Nensa, Felix; Gauler, Thomas; Gomez, Benedikt; Reis, Henning; Stamatis, Georgios; Kühl, Hilmar; Hartung, Verena; Heusner, Till A

    2014-03-01

    Therapeutic decisions in non-small cell lung cancer (NSCLC) patients depend on the tumor stage. PET/CT with (18)F-FDG is widely accepted as the diagnostic standard of care. The purpose of this study was to compare a dedicated pulmonary (18)F-FDG PET/MR imaging protocol with (18)F-FDG PET/CT for primary and locoregional lymph node staging in NSCLC patients using histopathology as the reference. Twenty-two patients (12 men, 10 women; mean age ± SD, 65.1 ± 9.1 y) with histopathologically confirmed NSCLC underwent (18)F-FDG PET/CT, followed by (18)F-FDG PET/MR imaging, including a dedicated pulmonary MR imaging protocol. T and N staging according to the seventh edition of the American Joint Committee on Cancer staging manual was performed by 2 readers in separate sessions for (18)F-FDG PET/CT and PET/MR imaging, respectively. Results from histopathology were used as the standard of reference. The mean and maximum standardized uptake value (SUV(mean) and SUV(max), respectively) and maximum diameter of the primary tumor was measured and compared in (18)F-FDG PET/CT and PET/MR imaging. PET/MR imaging and (18)F-FDG PET/CT agreed on T stages in 16 of 16 of patients (100%). All patients were correctly staged by (18)F-FDG PET/CT and PET/MR (100%), compared with histopathology. There was no statistically significant difference between (18)F-FDG PET/CT and (18)F-FDG PET/MR imaging for lymph node metastases detection (P = 0.48). For definition of thoracic N stages, PET/MR imaging and (18)F-FDG PET/CT were concordant in 20 of 22 patients (91%). PET/MR imaging determined the N stage correctly in 20 of 22 patients (91%). (18)F-FDG PET/CT determined the N stage correctly in 18 of 22 patients (82%). The mean differences for SUV(mean) and SUV(max) of NSCLC in (18)F-FDG PET/MR imaging and (18)F-FDG PET/CT were 0.21 and -5.06. These differences were not statistically significant (P > 0.05). The SUV(mean) and SUV(max) measurements derived from (18)F-FDG PET/CT and (18)F-FDG PET

  7. Fully automated synthesis of [(18) F]fluoro-dihydrotestosterone ([(18) F]FDHT) using the FlexLab module.

    PubMed

    Ackermann, Uwe; Lewis, Jason S; Young, Kenneth; Morris, Michael J; Weickhardt, Andrew; Davis, Ian D; Scott, Andrew M

    2016-08-01

    Imaging of androgen receptor expression in prostate cancer using F-18 FDHT is becoming increasingly popular. With the radiolabelling precursor now commercially available, developing a fully automated synthesis of [(18) F] FDHT is important. We have fully automated the synthesis of F-18 FDHT using the iPhase FlexLab module using only commercially available components. Total synthesis time was 90 min, radiochemical yields were 25-33% (n = 11). Radiochemical purity of the final formulation was > 99% and specific activity was > 18.5 GBq/µmol for all batches. This method can be up-scaled as desired, thus making it possible to study multiple patients in a day. Furthermore, our procedure uses 4 mg of precursor only and is therefore cost-effective. The synthesis has now been validated at Austin Health and is currently used for [(18) F]FDHT studies in patients. We believe that this method can easily adapted by other modules to further widen the availability of [(18) F]FDHT. Copyright © 2016 John Wiley & Sons, Ltd.

  8. USE OF OXYGEN-18 ISOTOPE LABELING FOR MEASUREMENT OF OXIDATIVE STRESS

    EPA Science Inventory

    Oxygen-18 (18-O) labeling provides a sensitive means for quantifying oxygen
    binding that occurs during in vivo oxidations. Oxidants (ozone, nitrogen
    oxides, hydrogen peroxide, etc.) are first synthesized using 18-O, then cells
    or tissues are exposed to the labeled ...

  9. The role of 18F-FDOPA and 18F-FDG-PET in the management of malignant and multifocal phaeochromocytomas.

    PubMed

    Taïeb, D; Tessonnier, L; Sebag, F; Niccoli-Sire, P; Morange, I; Colavolpe, C; De Micco, C; Barlier, A; Palazzo, F F; Henry, J F; Mundler, O

    2008-10-01

    (18)F-DOPA has emerged as a promising tool in the localization of chromaffin-tissue-derived tumours. Interestingly, phaeochromocytomas (PHEO) are also FDG avid. The aim of this study was to retrospectively evaluate the results of (18)F-FDOPA and/or (18)F-FDG-PET in patients with PHEO and paragangliomas (PGLs) and to compare the outcome of this approach with the traditional therapeutic work-up. Nine patients with non-MEN2 related PHEO or PGL were evaluated. At the time of the PET studies, the patients were classified into three groups based on their clinical history, conventional and SPECT imaging. The groups were malignant disease (n = 5, 1 VHL), apparently unique tumour site in patients with previous surgery (n = 1, SDHB) and multifocal tumours (n = 3, 1 VHL, 1 SDHD). (18)F-FDOPA and (18)F-FDG-PET PET/CT were then performed in all patients. PET successfully identified additional tumour sites in five out of five patients with metastatic disease that had not been identified with SPECT + CI. Whilst tumour tracer uptake varied between patients it exhibited a consistently favourable residence time for delayed acquisitions. (18)F-FDOPA uptake (SUVmax) was superior to (18)F-FDG uptake in cases of neck PGL (three patients, four tumours). If only metastatic forms and abdominal PGLs were considered, (18)F-FDG provided additional information in three cases (two metastatic forms, one multifocal disease with SDHD mutation) compared to (18)F-FDOPA. Our results suggest that tumour staging can be improved by combining (18)F-FDOPA and (18)F-FDG in the preoperative work-up of patients with abdominal and malignant PHEOs. (18)F-FDOPA is also an effective localization tool for neck PGLs. MIBG however, still has a role in these patients as MIBG and FDOPA images did not completely overlap.

  10. Optical reaction cell and light source for ›18F! fluoride radiotracer synthesis

    DOEpatents

    Ferrieri, Richard A.; Schlyer, David; Becker, Richard J.

    1998-09-15

    Apparatus for performing organic synthetic reactions, particularly no-carrier-added nucleophilic radiofluorination reactions for PET radiotracer production. The apparatus includes an optical reaction cell and a source of broadband infrared radiant energy, which permits direct coupling of the emitted radiant energy with the reaction medium to heat the reaction medium. Preferably, the apparatus includes means for focusing the emitted radiant energy into the reaction cell, and the reaction cell itself is preferably configured to reflect transmitted radiant energy back into the reaction medium to further improve the efficiency of the apparatus. The apparatus is well suited to the production of high-yield syntheses of 2-›.sup.18 F!fluoro-2-deoxy-D-glucose. Also provided is a method for performing organic synthetic reactions, including the manufacture of ›.sup.18 F!-labeled compounds useful as PET radiotracers, and particularly for the preparation of 2-›.sup.18 F!fluoro-2-deoxy-D-glucose in higher yields than previously possible.

  11. Expanding role of 18F-fluoro-d-deoxyglucose PET and PET/CT in spinal infections

    PubMed Central

    Rijk, Paul C.; Collins, James M. P.; Parlevliet, Thierry; Stumpe, Katrin D.; Palestro, Christopher J.

    2010-01-01

    18F-fluoro-d-deoxyglucose positron emission tomography ([18F]-FDG PET) is successfully employed as a molecular imaging technique in oncology, and has become a promising imaging modality in the field of infection. The non-invasive diagnosis of spinal infections (SI) has been a challenge for physicians for many years. Morphological imaging modalities such as conventional radiography, computed tomography (CT), and magnetic resonance imaging (MRI) are techniques frequently used in patients with SI. However, these methods are sometimes non-specific, and difficulties in differentiating infectious from degenerative end-plate abnormalities or postoperative changes can occur. Moreover, in contrast to CT and MRI, FDG uptake in PET is not hampered by metallic implant-associated artifacts. Conventional radionuclide imaging tests, such as bone scintigraphy, labeled leukocyte, and gallium scanning, suffer from relatively poor spatial resolution and lack sensitivity, specificity, or both. Initial data show that [18F]-FDG PET is an emerging imaging technique for diagnosing SI. [18F]-FDG PET appears to be especially helpful in those cases in which MRI cannot be performed or is non-diagnostic, and as an adjunct in patients in whom the diagnosis is inconclusive. The article reviews the currently available literature on [18F]-FDG PET and PET/CT in the diagnosis of SI. PMID:20052505

  12. False-positive 18F-fluorodeoxyglucose positron emission tomography/computed tomography in a patient with metallic implants following chondrosarcoma resection

    PubMed Central

    ZHOU, PU; TANG, JINLIANG; ZHANG, DONG; LI, GUANGHUI

    2016-01-01

    Positron emission tomography (PET) with fluorine-18-labeled fluorodeoxyglucose (18F-FDG) has been used for the staging and evaluation of recurrence in cancer patients. We herein report a false-positive result of 18F-FDG PET/computed tomography (CT) scan in a patient following chondrosarcoma resection and metallic implanting. A 35-year-old male patient with chondrosarcoma of the left iliac bone underwent radical resection, metal brace implanting and radiotherapy. A high uptake of 18F-FDG was observed in the metallic implants and adjacent tissue during PET/CT scanning in the 5th year of follow-up. Tissue biopsy and follow-up examination identified no tumor recurrence or infection at these sites, suggesting that the results of 18F-FDG PET/CT must be interpreted with caution in cancer patients with metallic implants. PMID:27123290

  13. Biodistribution and catabolism of (18)F-labeled neurotensin(8-13) analogs.

    PubMed

    Bergmann, Ralf; Scheunemann, Matthias; Heichert, Christoph; Mäding, Peter; Wittrisch, Holm; Kretzschmar, Marion; Rodig, Heike; Tourwé, Dirk; Iterbeke, Koen; Chavatte, Kris; Zips, Daniel; Reubi, Jean Claude; Johannsen, Bernd

    2002-01-01

    4-([(18)F]fluoro)benzoyl-neurotensin(8-13) ((18)FB-Arg(8)-Arg(9)-Pro(10)-Tyr(11)- Ile(12)-Leu(13)-OH, 1) and two analogs stabilized in one and two positions ((18)FB-Arg(8)psi(CH(2)NH)Arg(9)-Pro(10)-Tyr(11)- Ile(12)-Leu(13)-OH, 2, (18)FB-Arg(8)psi(CH(2)NH)Arg(9)-Pro(10)-Tyr(11)-Tle(12)-Leu(13)-OH, 3) were synthesized in a radiochemical yield of 25-36% and a specific activity of 5-15 GBq/mmol. The peptides were evaluated in vitro and in vivo for their potential to image tumors overexpressing neurotensin receptor 1 (NTR1) by positron emission tomography (PET). All analogs exhibited in vitro binding affinity in the low nanomolar range to NTR1-expressing human tumors, measured by quantitative receptor autoradiography, HT-29 and WiDr cells, and to sections of tumors derived from these cell lines in mice. The radiotracers were internalized in the cells in vitro, and the fluorinated peptides were able to mobilize intracellular Ca(2+) of WiDr cells. In in vivo studies in rats and in mice bearing HT-29 cell tumors, only a moderate uptake of the radioligands into the studied tumors was observed, presumed to be due to degradation in vivo and fast elimination by the kidneys. In comparison with the other analogs, the specific tumor uptake expressed as tumor-to-muscle relation was highest for the radioligand 3. The blood clearance of 3 was reduced by co-injection of peptidase inhibitors. The catabolic pathways of the radiofluorinated peptides were elucidated. The results suggest that the high binding affinity to NTR1 and the stabilization against proteolytic degradation are not yet sufficient for tumor imaging by PET.

  14. Protein 19F-labeling using transglutaminase for the NMR study of intermolecular interactions.

    PubMed

    Hattori, Yoshikazu; Heidenreich, David; Ono, Yuki; Sugiki, Toshihiko; Yokoyama, Kei-Ichi; Suzuki, Ei-Ichiro; Fujiwara, Toshimichi; Kojima, Chojiro

    2017-08-01

    The preparation of stable isotope-labeled proteins is important for NMR studies, however, it is often hampered in the case of eukaryotic proteins which are not readily expressed in Escherichia coli. Such proteins are often conveniently investigated following post-expression chemical isotope tagging. Enzymatic 15 N-labeling of glutamine side chains using transglutaminase (TGase) has been applied to several proteins for NMR studies. 19 F-labeling is useful for interaction studies due to its high NMR sensitivity and susceptibility. Here, 19 F-labeling of glutamine side chains using TGase and 2,2,2-trifluoroethylamine hydrochloride was established for use in an NMR study. This enzymatic 19 F-labeling readily provided NMR detection of protein-drug and protein-protein interactions with complexes of about 100 kDa since the surface residues provided a good substrate for TGase. The 19 F-labeling method was 3.5-fold more sensitive than 15 N-labeling, and could be combined with other chemical modification techniques such as lysine 13 C-methylation. 13 C-dimethylated- 19 F-labeled FKBP12 provided more accurate information concerning the FK506 binding site.

  15. 18F-Fluoride and 18F-Fluorodeoxyglucose Positron Emission Tomography After Transient Ischemic Attack or Minor Ischemic Stroke

    PubMed Central

    Jenkins, William S. A.; Irkle, Agnese; Moss, Alastair; Sng, Greg; Forsythe, Rachael O.; Clark, Tim; Roberts, Gemma; Fletcher, Alison; Lucatelli, Christophe; Rudd, James H. F.; Davenport, Anthony P.; Mills, Nicholas L.; Al-Shahi Salman, Rustam; Dennis, Martin; Whiteley, William N.; van Beek, Edwin J. R.; Dweck, Marc R.; Newby, David E.

    2017-01-01

    Background— Combined positron emission tomography (PET) and computed tomography (CT) can assess both anatomy and biology of carotid atherosclerosis. We sought to assess whether 18F-fluoride or 18F-fluorodeoxyglucose can identify culprit and high-risk carotid plaque. Methods and Results— We performed 18F-fluoride and 18F-fluorodeoxyglucose PET/CT in 26 patients after recent transient ischemic attack or minor ischemic stroke: 18 patients with culprit carotid stenosis awaiting carotid endarterectomy and 8 controls without culprit carotid atheroma. We compared standardized uptake values in the clinically adjudicated culprit to the contralateral asymptomatic artery, and assessed the relationship between radiotracer uptake and plaque phenotype or predicted cardiovascular risk (ASSIGN score [Assessing Cardiovascular Risk Using SIGN Guidelines to Assign Preventive Treatment]). We also performed micro PET/CT and histological analysis of excised plaque. On histological and micro PET/CT analysis, 18F-fluoride selectively highlighted microcalcification. Carotid 18F-fluoride uptake was increased in clinically adjudicated culprit plaques compared with asymptomatic contralateral plaques (log10standardized uptake valuemean 0.29±0.10 versus 0.23±0.11, P=0.001) and compared with control patients (log10standardized uptake valuemean 0.29±0.10 versus 0.12±0.11, P=0.001). 18F-Fluoride uptake correlated with high-risk plaque features (remodeling index [r=0.53, P=0.003], plaque burden [r=0.51, P=0.004]), and predicted cardiovascular risk [r=0.65, P=0.002]). Carotid 18F-fluorodeoxyglucose uptake appeared to be increased in 7 of 16 culprit plaques, but no overall differences in uptake were observed in culprit versus contralateral plaques or control patients. However, 18F-fluorodeoxyglucose did correlate with predicted cardiovascular risk (r=0.53, P=0.019), but not with plaque phenotype. Conclusions— 18F-Fluoride PET/CT highlights culprit and phenotypically high-risk carotid plaque

  16. Evaluation of Prostate Cancer with 11C- and 18F-Choline PET/CT: Diagnosis and Initial Staging.

    PubMed

    Nitsch, Sascha; Hakenberg, Oliver W; Heuschkel, Martin; Dräger, Desiree; Hildebrandt, Guido; Krause, Bernd J; Schwarzenböck, Sarah M

    2016-10-01

    Early diagnosis and adequate staging are crucial for the choice of adequate treatment in prostate cancer (PC). Morphologic and functional imaging modalities, such as CT and MRI, have had limited accuracy in the diagnosis and nodal staging of PC. Molecular PET/CT imaging with 11 C- or 18 F-choline-labeled derivatives is increasingly being used, but its role in the diagnosis and initial staging of PC is controversial because of limitations in sensitivity and specificity for the detection of primary PC. For T staging, functional MRI is superior to 11 C- or 18 F-choline PET/CT. For N staging, 11 C- or 18 F-choline PET/CT can provide potentially useful information that may influence treatment planning. For the detection of bone metastases, 11 C- or 18 F-choline PET/CT has had promising results; however, in terms of cost-effectiveness, the routine use of 11 C- or 18 F-choline PET/CT is still debatable. 11 C- or 18 F-choline PET/CT might be used in high-risk PC before radiation treatment planning, potentially affecting this planning (e.g., regarding dose escalation). This review provides an overview of the diagnostic accuracy and limitations of 11 C- or 18 F-choline PET/CT in the diagnosis and staging of PC. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  17. WE-H-207A-05: Spatial Co-Localization of F-18 NaF Vs. F-18 FDG Defined Disease Volumes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ferjancic, P; Harmon, S; Jeraj, R

    Purpose: Both [F-18]NaF and [F-18]FDG show promise for quantitative PET/CT assessment in metastatic prostate cancer to bone. Broad agreement between the tracers has been shown but voxel-wise correspondence has not been explored in depth. This study evaluates the spatial co-localization of [F-18]NaF PET and [F-18]FDG PET in bone lesions. Methods: Seventy-three lesion contours were identified in six patients receiving dynamic NaF PET/CT and FDG PET/CT scans two hours apart using identical fields-of-view. Tracer uptake (SUV) reflecting 60 minutes post-injection was modeled from kinetic parameters. Lesions were segmented by a physician separately on NaF PET and FDG PET. PET images weremore » rigidly aligned using skeletal references on CT images. Lesion size, degree of overlap, voxel-wise tracer uptake values (SUV), and CT density distributions were compared using Dice coefficient, Positive Predictive Value (PPV), and Spearman rank correlation tests. Results: Across all patients, 42 lesions were identified on NaF PET (median 1.4 cm{sup 3}, range <1–204 cm{sup 3}) compared to 31 using FDG PET (median 1.8 cm{sup 3}, range <1–244 cm{sup 3}). Spatial cooccurrence was found in 25 lesion pairs. Lesions on NaF PET had PPV of 0.91 and on FDG a PPV of 0.65. Overall, NaF-defined lesions were 47% (±24%) larger by volume with moderate overlap to FDG, resulting in mean Dice coefficient of 34% (±22%). In areas of overlap, voxel-wise correlation of NaF and FDG SUV was moderate (ρ=0.56). Expanding to regions of non-spatial overlap, voxels contained in FDG-only contours were almost exclusively low HU (median 118), compared to dense regions of NaF-only voxels (median 250). In sclerotic sub-volumes (HU > 300) NaF-defined contours encompassed 83% of total FDG volume. Conclusion: Moderate voxel-wise correlation of FDG and NaF PET/CT uptake was observed. Spatial discrepancies in FDG and NaF PET/CT imaging of boney metastases could be influenced by poor sensitivity of FDG PET/CT in

  18. Evaluation of an [(18)F]AlF-NOTA Analog of Exendin-4 for Imaging of GLP-1 Receptor in Insulinoma.

    PubMed

    Kiesewetter, Dale O; Guo, Ning; Guo, Jinxia; Gao, Haokao; Zhu, Lei; Ma, Ying; Niu, Gang; Chen, Xiaoyuan

    2012-01-01

    The GLP-1 receptor plays an important role in glucose homeostasis and thus is a very important target for diabetes therapy. The receptor is also overexpressed in insulinoma, a tumor of pancreatic beta-cells. We previously evaluated two fluorine-18-labeled analogs of exendin-4 prepared by conjugation with [(18)F]FBEM (N-[2-(4-[(18)F]fluorobenzamide)ethyl]maleimide). Both compounds demonstrated good tumor uptake, but the synthesis of the radiotracers was time consuming. To overcome this challenge, we developed a NOTA analog and performed radiolabeling using aluminum [(18)F]fluoride complexation. Cys(40)-exendin-4 was conjugated with NOTA mono N-ethylmaleimide. [(18)F]AlF conjugation was conducted and the radiolabeled product purified by preparative HPLC. Dynamic and static PET imaging scans were conducted on nude mice with established INS-1 xenografts. Uptake of tumor and other major organs in static images was quantitated (%ID/g) and comparison with blocking studies was made. PET quantification was also compared with ex vivo biodistribution results. The radiosynthesis provided [(18)F]AlF-NOTA-MAL-cys(40)-exendin-4 in 23.6 ± 2.4 % radiochemical yield (uncorrected, n = 3) after HPLC; the process required about 55 min. The specific activity at time of injection ranged from 19.6 to 31.4 GBq (0.53-0.85 Ci)/µmol. Tumor uptake had reached its maximum (16.09 ± 1.18% ID/g, n = 4) by 5 min and remained nearly constant for the duration of the study. Kidney uptake continued to increase throughout the entire one hour time course. Pre-injection of exendin-4 caused a marked reduction in tissue uptake with the major exception of liver and kidneys, in which uptake was not affected. HPLC analysis of the radioactive components in extracts of the tumor and plasma showed primarily parent compound at 60 min post-injection, whereas extracts of kidney and urine contained exclusively one polar radioactive component. The radiotracer is prepared in a simple one-step procedure and obtained

  19. Functional Renal Imaging with 2-Deoxy-2-18F-Fluorosorbitol PET in Rat Models of Renal Disorders.

    PubMed

    Werner, Rudolf A; Wakabayashi, Hiroshi; Chen, Xinyu; Hirano, Mitsuru; Shinaji, Tetsuya; Lapa, Constantin; Rowe, Steven P; Javadi, Mehrbod S; Higuchi, Takahiro

    2018-05-01

    Precise regional quantitative assessment of renal function is limited with conventional 99m Tc-labeled renal radiotracers. A recent study reported that the PET radiotracer 2-deoxy-2- 18 F-fluorosorbitol ( 18 F-FDS) has ideal pharmacokinetics for functional renal imaging. Furthermore, 18 F-FDS is available via simple reduction from routinely used 18 F-FDG. We aimed to further investigate the potential of 18 F-FDS PET as a functional renal imaging agent using rat models of kidney disease. Methods: Two different rat models of renal impairment were investigated: induction of acute renal failure by intramuscular administration of glycerol in the hind legs, and induction of unilateral ureteral obstruction by ligation of the left ureter. At 24 h after these procedures, dynamic 30-min 18 F-FDS PET data were acquired using a dedicated small-animal PET system. Urine 18 F-FDS radioactivity 30 min after radiotracer injection was measured together with coinjected 99m Tc-diethylenetriaminepentaacetic acid urine activity. Results: Dynamic PET imaging demonstrated rapid 18 F-FDS accumulation in the renal cortex and rapid radiotracer excretion via the kidneys in healthy control rats. On the other hand, significantly delayed renal radiotracer uptake (continuous slow uptake) was observed in acute renal failure rats and unilateral ureteral obstruction kidneys. Measured urine radiotracer concentrations of 18 F-FDS and 99m Tc-diethylenetriaminepentaacetic acid correlated well with each other ( R = 0.84, P < 0.05). Conclusion: 18 F-FDS PET demonstrated favorable kinetics for functional renal imaging in rat models of kidney diseases. 18 F-FDS PET imaging, with its advantages of high spatiotemporal resolution and simple tracer production, could potentially complement or replace conventional renal scintigraphy in select cases and significantly improve the diagnostic performance of renal functional imaging. © 2018 by the Society of Nuclear Medicine and Molecular Imaging.

  20. Imaging melphalan therapy response in preclinical extramedullary myeloma with 18F-FDOPA and 18F-FDG PET.

    PubMed

    Hathi, Deep; DeLassus, Elizabeth; Achilefu, Samuel; McConathy, Jonathan; Shokeen, Monica

    2018-04-26

    Multiple myeloma (MM) is a debilitating neoplasm of terminally differentiated plasma B-cells that has resulted in over 13,000 deaths in 2017 alone. Combination therapies involving melphalan, a small molecule DNA alkylating agent, are commonly prescribed to patients with relapsed/refractory MM, which necessitates the stratification of responding patients to minimize toxicities and improve quality of life. Here, we evaluated the use of 18 F-FDOPA, a clinically available positron emission tomography (PET) radiotracer with specificity to the L-type amino acid transporter-1 (LAT1), which also mediates melphalan uptake, for imaging melphalan therapy response in a preclinical immunocompetent model of MM. Methods: C57Bl/KaLwRij mice were implanted subcutaneously with unilateral murine 5TGM1-GFP tumors, and divided into three independent groups: untreated, treated beginning week 2, and treated beginning week 3 post tumor implantation. The untreated and week 2 therapy cohorts were imaged with preclinical magnetic resonance imaging (MRI) and dynamic 18 F-FDG and 18 F-FDOPA-PET/computed tomography (PET/CT) at week 4 on separate, contiguous days, while the week 3 therapy cohort was longitudinally imaged weekly for 2 weeks. Metabolic tumor volume, lesion avidity, maximum standard uptake value, and total uptake metrics were calculated for both tracers. Immunohistochemistry was performed on representative tissue from all groups for LAT1 and glucose transporter-1 (GLUT1) expression. Results: Melphalan therapy induced a statistically significant reduction in lesion avidity and uptake metrics for both 18 F-FDG and 18 F-FDOPA. There was no visible effect on GLUT1 expression, but LAT1 density was increased in the week 2 therapy cohort. Longitudinal imaging of the week 3 group showed variable changes in 18 F-FDG and 18 F-FDOPA uptake, with increase in 18 F-FDOPA lesion avidity in the 2nd week relative to baseline. LAT1 and GLUT1 surface density in the untreated tumor and week 3

  1. (18)F-alfatide II and (18)F-FDG dual-tracer dynamic PET for parametric, early prediction of tumor response to therapy.

    PubMed

    Guo, Jinxia; Guo, Ning; Lang, Lixin; Kiesewetter, Dale O; Xie, Qingguo; Li, Quanzheng; Eden, Henry S; Niu, Gang; Chen, Xiaoyuan

    2014-01-01

    A single dynamic PET acquisition using multiple tracers administered closely in time could provide valuable complementary information about a tumor's status under quasiconstant conditions. This study aimed to investigate the utility of dual-tracer dynamic PET imaging with (18)F-alfatide II ((18)F-AlF-NOTA-E[PEG4-c(RGDfk)]2) and (18)F-FDG for parametric monitoring of tumor responses to therapy. We administered doxorubicin to one group of athymic nude mice with U87MG tumors and paclitaxel protein-bound particles to another group of mice with MDA-MB-435 tumors. To monitor therapeutic responses, we performed dual-tracer dynamic imaging, in sessions that lasted 90 min, starting with injection via the tail vein catheters with (18)F-alfatide II, followed 40 min later by (18)F-FDG. To achieve signal separation of the 2 tracers, we fit a 3-compartment reversible model to the time-activity curve of (18)F-alfatide II for the 40 min before (18)F-FDG injection and then extrapolated to 90 min. The (18)F-FDG tumor time-activity curve was isolated from the 90-min dual-tracer tumor time-activity curve by subtracting the fitted (18)F-alfatide II tumor time-activity curve. With separated tumor time-activity curves, the (18)F-alfatide II binding potential (Bp = k3/k4) and volume of distribution (VD) and (18)F-FDG influx rate ((K1 × k3)/(k2 + k3)) based on the Patlak method were calculated to validate the signal recovery in a comparison with 60-min single-tracer imaging and to monitor therapeutic response. The transport and binding rate parameters K1-k3 of (18)F-alfatide II, calculated from the first 40 min of the dual-tracer dynamic scan, as well as Bp and VD correlated well with the parameters from the 60-min single-tracer scan (R(2) > 0.95). Compared with the results of single-tracer PET imaging, (18)F-FDG tumor uptake and influx were recovered well from dual-tracer imaging. On doxorubicin treatment, whereas no significant changes in static tracer uptake values of (18)F-alfatide II

  2. 18F-Alfatide II and 18F-FDG Dual Tracer Dynamic PET for Parametric, Early Prediction of Tumor Response to Therapy

    PubMed Central

    Guo, Jinxia; Guo, Ning; Lang, Lixin; Kiesewetter, Dale O.; Xie, Qingguo; Li, Quanzheng; Eden, Henry S.; Niu, Gang; Chen, Xiaoyuan

    2014-01-01

    A single dynamic PET acquisition using multiple tracers administered closely in time could provide valuable complementary information about a tumor’s status under quasi-constant conditions. This study aims to investigate the utility of dual-tracer dynamic PET imaging with 18F-Alfatide II (18F-AlF-NOTA-E[PEG4-c(RGDfk)]2) and 18F-FDG for parametric monitoring of tumor responses to therapy. Methods We administered doxorubicin to one group of athymic nude mice with U87MG tumors and Abraxane to another group of mice with MDA-MB-435 tumors. To monitor therapeutic responses, we performed dual-tracer dynamic imaging, in sessions that lasted 90 min, starting by injecting the mice via tail vein catheters with 18F-Alfatide II, followed 40 minutes later by 18F-FDG. To achieve signal separation of the two tracers, we fit a three-compartment reversible model to the time activity curve (TAC) of 18F-Alfatide II for the 40 min prior to 18F-FDG injection, and then extrapolated to 90 min. The 18F-FDG tumor TAC was isolated from the 90 min dual tracer tumor TAC by subtracting the fitted 18F-Alfatide II tumor TAC. With separated tumor TACs, the 18F-Alfatide II binding potential (Bp=k3/k4) and volume of distribution (VD), and 18F-FDG influx rate ((K1×k3)/(k2 + k3)) based on the Patlak method were calculated to validate the signal recovery in a comparison with 60-min single tracer imaging and to monitor therapeutic response. Results The transport and binding rate parameters K1-k3 of 18F-Alfatide II, calculated from the first 40 min of dual tracer dynamic scan, as well as Bp and VD, correlated well with the parameters from the 60 min single tracer scan (R2 > 0.95). Compared with the results of single tracer PET imaging, FDG tumor uptake and influx were recovered well from dual tracer imaging. Upon doxorubicin treatment, while no significant changes in static tracer uptake values of 18F-Alfatide II or 18F-FDG were observed, both 18F-Alfatide II Bp and 18F-FDG influx from kinetic

  3. Fully automated SPE-based synthesis and purification of 2-[18F]fluoroethyl-choline for human use.

    PubMed

    Schmaljohann, Jörn; Schirrmacher, Esther; Wängler, Björn; Wängler, Carmen; Schirrmacher, Ralf; Guhlke, Stefan

    2011-02-01

    procedures verified that the described production method for [(18)F]FECH is suitable for human applications. The routine production of [(18)F]FECH with sufficient RCYs was established by reliable and fast solid-phase extraction purifications of both the secondary labeling precursor [(18)F]BFE and the final product [(18)F]FECH, avoiding complex and sensitive HPLC equipment. The purity of the product was >95%, rendering the tracer suitable for human application. The newly developed purification procedure for [(18)F]BFE significantly reduces the complexity of the automated synthesis unit, hence reducing the cost for routine production in a clinical setup and allowing easy transfer to different synthesis modules. Copyright © 2011 Elsevier Inc. All rights reserved.

  4. Automated PET Radiotracer Manufacture on the BG75 System and Imaging Validation Studies of [18F]fluoromisonidazole ([18F]FMISO).

    PubMed

    Yuan, Hong; Frank, Jonathan E; Merrill, Joseph R; Hillesheim, Daniel A; Khachaturian, Mark H; Anzellotti, Atilio I

    2016-01-01

    The hypoxia PET tracer, 1-[18F]fluoro-3-(2-nitro-1Himidazol- 1-yl)-propan-2-ol ([18F]FMISO) is the first radiotracer developed for hypoxia PET imaging and has shown promising for cancer diagnosis and prognosis. However, access to [18F]FMISO radiotracer is limited due to the needed cyclotron and radiochemistry expertise. The study aimed to develop the automated production method on the [18F]FMISO radiotracer with the novel fully automated platform of the BG75 system and validate its usage on animal tumor models. [18F]FMISO was produced with the dose synthesis cartridge automatically on the BG75 system. Validation of [18F]FMISO hypoxia imaging functionality was conducted on two tumor mouse models (FaDu/U87 tumor). The distribution of [18F]FMISO within tumor was further validated by the standard hypoxia marker EF5. The average radiochemical purity was (99±1) % and the average pH was 5.5±0.2 with other quality attributes passing standard criteria (n=12). Overall biodistribution for [18F]FMISO in both tumor models was consistent with reported studies where bladder and large intestines presented highest activity at 90 min post injection. High spatial correlation was found between [18F]FMISO autoradiography and EF5 hypoxia staining, indicating high hypoxia specificity of [18MF]FMISO. This study shows that qualified [18F]FMISO can be efficiently produced on the BG75 system in an automated "dose-on-demand" mode using single dose disposable cards. The possibilities of having a low-cost, automated system manufacturing ([18F]Fluoride production + synthesis + QC) different radiotracers will greatly enhance the potential for PET technology to reach new geographical areas and underserved patient populations. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  5. Radiosynthesis of carbon-11 and fluorine-18 labelled radiotracers to image the ionotropic and metabotropic glutamate receptors.

    PubMed

    Sobrio, Franck

    2013-01-01

    l-Glutamate is the major neurotransmitter in the central nervous system and activates both ionotropic and metabotropic receptors. Here the radiosynthesis of radiotracers developed for both types of receptors are reviewed with a highlight on the radiopharmaceuticals used or evaluated in humans. At first, radiotracers were developed for ionotropic N-methyl-d-aspartate receptors without any success to obtain radiopharmaceuticals useable for clinical or even preclinical positron emission tomography (PET) imaging purposes. Some compounds were radiolabelled and evaluated for α-amino-3-hydroxy-5-methyl-4-isoxazolepropionic acid receptors without any successful results. The recent development of radiotracers for metabotropic glutamate receptors was more efficient because radiopharmaceuticals are currently evaluated or used in clinical trials to study the mGluR1, mGluR2 or mGluR5 receptors by PET. Although the majority of the radiotracers were classically labelled with carbon-11 by O- or N-[(11) C]-methylation or with fluorine-18 nucleophilic substitution of aromatic nitro or halogeno precursors using krypofix 2.2.2/potassium [(18) F]fluoride complex, some radiosyntheses were performed with recent radiolabelling reactions like the use of iodionium salt for [(18) F]-labelling. Copyright © 2013 John Wiley & Sons, Ltd.

  6. 18F-FDG positron autoradiography with a particle counting silicon pixel detector.

    PubMed

    Russo, P; Lauria, A; Mettivier, G; Montesi, M C; Marotta, M; Aloj, L; Lastoria, S

    2008-11-07

    We report on tests of a room-temperature particle counting silicon pixel detector of the Medipix2 series as the detector unit of a positron autoradiography (AR) system, for samples labelled with (18)F-FDG radiopharmaceutical used in PET studies. The silicon detector (1.98 cm(2) sensitive area, 300 microm thick) has high intrinsic resolution (55 microm pitch) and works by counting all hits in a pixel above a certain energy threshold. The present work extends the detector characterization with (18)F-FDG of a previous paper. We analysed the system's linearity, dynamic range, sensitivity, background count rate, noise, and its imaging performance on biological samples. Tests have been performed in the laboratory with (18)F-FDG drops (37-37 000 Bq initial activity) and ex vivo in a rat injected with 88.8 MBq of (18)F-FDG. Particles interacting in the detector volume produced a hit in a cluster of pixels whose mean size was 4.3 pixels/event at 11 keV threshold and 2.2 pixels/event at 37 keV threshold. Results show a sensitivity for beta(+) of 0.377 cps Bq(-1), a dynamic range of at least five orders of magnitude and a lower detection limit of 0.0015 Bq mm(-2). Real-time (18)F-FDG positron AR images have been obtained in 500-1000 s exposure time of thin (10-20 microm) slices of a rat brain and compared with 20 h film autoradiography of adjacent slices. The analysis of the image contrast and signal-to-noise ratio in a rat brain slice indicated that Poisson noise-limited imaging can be approached in short (e.g. 100 s) exposures, with approximately 100 Bq slice activity, and that the silicon pixel detector produced a higher image quality than film-based AR.

  7. Association Between Osteogenesis and Inflammation During the Progression of Calcified Plaque Evaluated by 18F-Fluoride and 18F-FDG.

    PubMed

    Li, Xiang; Heber, Daniel; Cal-Gonzalez, Jacobo; Karanikas, Georgios; Mayerhoefer, Marius E; Rasul, Sazan; Beitzke, Dietrich; Zhang, Xiaoli; Agis, Hermine; Mitterhauser, Markus; Wadsak, Wolfgang; Beyer, Thomas; Loewe, Christian; Hacker, Marcus

    2017-06-01

    18 F-FDG is the most widely validated PET tracer for the evaluation of atherosclerotic inflammation. Recently, 18 F-NaF has also been considered a potential novel biomarker of osteogenesis in atherosclerosis. We aimed to analyze the association between inflammation and osteogenesis at different stages of atherosclerosis, as well as the interrelationship between these 2 processes during disease progression. Methods: Thirty-four myeloma patients underwent 18 F-NaF and 18 F-FDG PET/CT examinations. Lesions were divided into 3 groups (noncalcified, mildly calcified, and severely calcified lesions) on the basis of calcium density as measured in Hounsfield units by CT. Tissue-to-background ratios were determined from PET for both tracers. The association between inflammation and osteogenesis during atherosclerosis progression was evaluated in 19 patients who had at least 2 examinations with both tracers. Results: There were significant correlations between the maximum tissue-to-background ratios of the 2 tracers (Spearman r = 0.5 [ P < 0.01]; Pearson r = 0.4 [ P < 0.01]) in the 221 lesions at baseline. The highest uptake of both tracers was observed in noncalcified lesions, but without any correlation between the tracers (Pearson r = 0.06; P = 0.76). Compared with noncalcified plaques, mildly calcified plaques showed concordant significantly lower accumulation, with good correlation between the tracers (Pearson r = 0.7; P < 0.01). In addition, enhanced osteogenesis-derived 18 F-NaF uptake and regressive inflammation-derived 18 F-FDG uptake were observed in severely calcified lesions (Pearson r = 0.4; P < 0.01). During follow-up, increased calcium density and increased mean 18 F-NaF uptake were observed, whereas mean 18 F-FDG uptake decreased. Most noncalcified (86%) and mildly calcified (81%) lesions and 47% of severely calcified lesions had concordant development of both vascular inflammation and osteogenesis. Conclusion: The combination of 18 F-NaF PET imaging and 18 F

  8. Functional imaging of SDHx-related head and neck paragangliomas: comparison of 18F-fluorodihydroxyphenylalanine, 18F-fluorodopamine, 18F-fluoro-2-deoxy-D-glucose PET, 123I-metaiodobenzylguanidine scintigraphy, and 111In-pentetreotide scintigraphy.

    PubMed

    King, Kathryn S; Chen, Clara C; Alexopoulos, Dimitrios K; Whatley, Millie A; Reynolds, James C; Patronas, Nicholas; Ling, Alexander; Adams, Karen T; Xekouki, Paraskevi; Lando, Howard; Stratakis, Constantine A; Pacak, Karel

    2011-09-01

    Accurate diagnosis of head and neck paragangliomas is often complicated by biochemical silence and lack of catecholamine-associated symptoms, making accurate anatomical and functional imaging techniques essential to the diagnostic process. Ten patients (seven SDHD, three SDHB), with a total of 26 head and neck paragangliomas, were evaluated with anatomical and functional imaging. This study compares five different functional imaging techniques [(18)F-fluorodihydroxyphenylalanine ((18)F-FDOPA) positron emission tomography (PET), (18)F-fluorodopamine ((18)F-FDA) PET/computed tomography (CT), (18)F-fluoro-2-deoxy-D-glucose ((18)F-FDG) PET/CT, (123)I-metaiodobenzylguanidine ((123)I-MIBG) scintigraphy, and (111)In-pentetreotide scintigraphy] in the localization of head and neck paragangliomas. Prospectively (18)F-FDOPA PET localized 26 of 26 lesions in the 10 patients, CT/magnetic resonance imaging localized 21 of 26 lesions, (18)F-FDG PET/CT localized 20 of 26 lesions, (111)In-pentetreotide scintigraphy localized 16 of 25 lesions, (18)F-FDA PET/CT localized 12 of 26 lesions, and (123)I-MIBG scintigraphy localized eight of 26 lesions. Differences in imaging efficacy related to genetic phenotype, even in the present small sample size, included the negativity of (18)F-FDA PET/CT and (123)I-MIBG scintigraphy in patients with SDHB mutations and the accuracy of (18)F-FDG PET/CT in all patients with SDHD mutations, as compared with the accuracy of (18)F-FDG PET/CT in only one patient with an SDHB mutation. Overall, (18)F-FDOPA PET proved to be the most efficacious functional imaging modality in the localization of SDHx-related head and neck paragangliomas and may be a potential first-line functional imaging agent for the localization of these tumors.

  9. N-(4-[18F]fluorobenzyl)cholylglycine, a novel tracer for PET of enterohepatic circulation of bile acids: Radiosynthesis and proof-of-concept studies in rats.

    PubMed

    Frisch, Kim; Stimson, Damion H R; Venkatachalam, Taracad; Pierens, Gregory K; Keiding, Susanne; Reutens, David; Bhalla, Rajiv

    2018-05-04

    Enterohepatic circulation (EHC) of conjugated bile acids is an important physiological process crucial for regulation of intracellular concentrations of bile acids and their function as detergents and signal carriers. Only few bile acid-derived imaging agents have been synthesized and hitherto none have been evaluated for studies of EHC. We hypothesized that N-(4-[ 18 F]fluorobenzyl)cholylglycine ([ 18 F]FBCGly), a novel fluorine-18 labeled derivative of endogenous cholylglycine, would be a suitable tracer for PET of the EHC of conjugated bile acids, and we report here a radiosynthesis of [ 18 F]FBCGly and a proof-of-concept study by PET/MR in rats. A radiosynthesis of [ 18 F]FBCGly was developed based on reductive alkylation of glycine with 4-[ 18 F]fluorobenzaldehyde followed by coupling to cholic acid. [ 18 F]FBCGly was investigated in vivo by dynamic PET/MR in anesthetized rats; untreated or treated with cholyltaurine or rifampicin. Possible in vivo metabolites of [ 18 F]FBCGly were investigated by analysis of blood and bile samples, and the stability of [ 18 F]FBCGly towards enzymatic de-conjugation by Cholylglycine Hydrolase was tested in vitro. [ 18 F]FBCGly was produced with a radiochemical purity of 96% ± 1% and a non-decay corrected radiochemical yield of 1.0% ± 0.3% (mean ± SD; n = 12). PET/MR studies showed that i.v.-administrated [ 18 F]FBCGly underwent EHC within 40-60 min with a rapid transhepatic transport from blood to bile. In untreated rats, the radioactivity concentration of [ 18 F]FBCGly was approximately 15 times higher in bile than in liver tissue. Cholyltaurine and rifampicin inhibited the biliary secretion of [ 18 F]FBCGly. No fluorine-18 metabolites of [ 18 F]FBCGly were observed. We have developed a radiosynthesis of a novel fluorine-18 labeled bile acid derivative, [ 18 F]FBCGly, and shown by PET/MR that [ 18 F]FBCGly undergoes continuous EHC in rats without metabolizing. This novel tracer may prove useful in PET

  10. Quantitative Receptor-Based Imaging of Tumor Proliferation with the Sigma-2 Ligand [18F]ISO-1

    PubMed Central

    Shoghi, Kooresh I.; Xu, Jinbin; Su, Yi; He, June; Rowland, Douglas; Yan, Ying; Garbow, Joel R.; Tu, Zhude; Jones, Lynne A.; Higashikubo, Ryuji; Wheeler, Kenneth T.; Lubet, Ronald A.; Mach, Robert H.; You, Ming

    2013-01-01

    The sigma-2 receptor is expressed in higher density in proliferating (P) tumor cells versus quiescent (Q) tumor cells, thus providing an attractive target for imaging the proliferative status (i.e., P:Q ratio) of solid tumors. Here we evaluate the utility of the sigma-2 receptor ligand 2-(2-[18F]fluoroethoxy)-N-(4-(3,4-dihydro-6,7-dimethoxyisoquinolin-2(1H)-yl)butyl)-5-methyl-benzamide, [18F]ISO-1, in two different rodent models of breast cancer. In the first study, small animal Positron Emission Tomography (PET) imaging studies were conducted with [18F]ISO-1 and 18FDG in xenografts of mouse mammary tumor 66 and tracer uptake was correlated with the in vivo P:Q ratio determined by flow cytometric measures of BrdU-labeled tumor cells. The second model utilized a chemically-induced (N-methyl-N-nitrosourea [MNU]) model of rat mammary carcinoma to correlate measures of [18F]ISO-1 and FDG uptake with MR-based volumetric measures of tumor growth. In addition, [18F]ISO-1 and FDG were used to assess the response of MNU-induced tumors to bexarotene and Vorozole therapy. In the mouse mammary 66 tumors, a strong linear correlation was observed between the [18F]ISO-1 tumor: background ratio and the proliferative status (P:Q ratio) of the tumor (R = 0.87). Similarly, measures of [18F]ISO-1 uptake in MNU-induced tumors significantly correlated (R = 0.68, P<0.003) with changes in tumor volume between consecutive MR imaging sessions. Our data suggest that PET studies of [18F]ISO-1 provide a measure of both the proliferative status and tumor growth rate, which would be valuable in designing an appropriate treatment strategy. PMID:24073202

  11. Synthesis of geminal difluorides by oxidative desulfurization-difluorination of alkyl aryl thioethers with halonium electrophiles in the presence of fluorinating reagents and its application for 18F-radiolabeling.

    PubMed

    Hugenberg, Verena; Wagner, Stefan; Kopka, Klaus; Schober, Otmar; Schäfers, Michael; Haufe, Günter

    2010-09-17

    Various ω-substituted 1,1-difluoroalkanes are synthesized in good yields from alkyl aryl thioethers by a new oxidative desulfurization-difluorination protocol with the reagents combination of 1,3-dibromo-5,5-dimethylhydantoin (DBH) as an oxidizer and pyridine·9HF (Py·9HF) as a fluoride source. The reaction proceeds via a fluoro-Pummerer-type rearrangement followed by an oxidative desulfurization-fluorination step. Starting from α-fluorinated thioethers, this reaction is promising for (18)F-labeling (τ(1/2) = 110 min) of ligands applicable for positron emission tomography (PET). Using the combination of DBH and carrier-added Py·9H[(18)F]F, an (18)F-labeled difluoride was synthesized from the corresponding α-fluoro thioether with a radiochemical yield of 9%.

  12. Comparative evaluation of 18F-FLT and 18F-FDG for detecting cardiac and extra-cardiac thoracic involvement in patients with newly diagnosed sarcoidosis.

    PubMed

    Norikane, Takashi; Yamamoto, Yuka; Maeda, Yukito; Noma, Takahisa; Dobashi, Hiroaki; Nishiyama, Yoshihiro

    2017-08-29

    18 F-FDG PET has been used in sarcoidosis for diagnosis and determination of the extent of the disease. However, assessing inflammatory lesions in cardiac sarcoidosis using 18 F-FDG can be challenging because it accumulates physiologically in normal myocardium. Another radiotracer, 3'-deoxy-3'- 18 F-fluorothymidine ( 18 F-FLT), has been investigated as a promising PET tracer for evaluating tumor proliferative activity. In contrast to 18 F-FDG, 18 F-FLT uptake in the normal myocardium is low. The purpose of this retrospective study was to compare the uptake of 18 F-FLT and 18 F-FDG in the evaluation of cardiac and extra-cardiac thoracic involvement in patients with newly diagnosed sarcoidosis. Data for 20 patients with newly diagnosed sarcoidosis were examined. 18 F-FLT and 18 F-FDG PET/CT studies had been performed at 1 h after each radiotracer injection. The patients had fasted for at least 18 h before 18 F-FDG PET/CT but were given no special dietary instructions regarding the period before 18 F-FLT PET/CT. Uptake of 18 F-FLT and 18 F-FDG was examined visually and semiquantitatively using maximal standardized uptake value (SUVmax). Two patients had cardiac sarcoidosis, 7 had extra-cardiac thoracic sarcoidosis, and 11 had both cardiac and extra-cardiac thoracic sarcoidosis. On visual analysis for diagnosis of cardiac sarcoidosis, 4/20 18 F-FDG scans were rated as inconclusive because the 18 F-FDG pattern was diffuse, whereas no FLT scans were rated as inconclusive. The sensitivity of 18 F-FDG PET/CT for detection of cardiac sarcoidosis was 85%; specificity, 100%; and accuracy, 90%. The corresponding values for 18 F-FLT PET/CT were 92, 100, and 95%, respectively. Using semiquantitative analysis of cardiac sarcoidosis, the mean 18 F-FDG SUVmax was significantly higher than the mean 18 F-FLT SUVmax (P < 0.005). Both 18 F-FDG and 18 F-FLT PET/CT studies detected all 24 extra-cardiac lesions. Using semiquantitative analysis of extra-cardiac sarcoidosis, the mean 18

  13. Relationship Between Clinicopathological Characteristics and PET/CT Uptake in Esophageal Squamous Cell Carcinoma: [18F]Alfatide versus [18F]FDG.

    PubMed

    Dong, Yinjun; Wei, Yuchun; Chen, Guanxuan; Huang, Yong; Song, Pingping; Liu, Shuguang; Zheng, Jinsong; Cheng, Monica; Yuan, Shuanghu

    2018-06-04

    To assess a novel radiotracer aluminum [ 18 F]fluoride-1,4,7-triazacyclononane-triacetic acid-pegylated dimeric RGD ([ 18 F]ALF-NOTA-PRGD 2 , denoted as [ 18 F]Alfatide) for positron emission tomography (PET)/X-ray computed tomography (CT) and explore the relationships between clinicopathological characteristics and maximum standard uptake values in primary (SUV P ) and metastatic lymph nodes (SUV LN ) of patients with esophageal squamous cell carcinoma (ESCC), as verified by pathologic examination and compared with those obtained with 2-deoxy-2-[ 18 F]fluoro-D-glucose ([ 18 F]DG) PET. We prospectively enrolled patients with newly diagnosed ESCC who agreed to undergo [ 18 F]Alfatide PET/CT or [ 18 F]FDG PET/CT scans before surgery at Shandong Cancer Hospital from May 2011 to July 2017. SUVs and the pathological tumor-node-metastasis (pTNM) stages of primary tumors and metastatic lymph nodes (LNs) were measured and confirmed pathologically. Immunohistochemical (IHC) staining for integrin αvβ3 was performed on tumor samples (both primary tumors and metastatic LNs) collected from nine patients. Of 61 patients who underwent PET/CT scans, 46 then underwent curative surgery and were included in our analysis (n = 21 for [ 18 F]Alfatide PET/CT and n = 25 for [ 18 F]FDG PET/CT). No significant differences in the SUV P on [ 18 F]Alfatide PET/CT or [ 18 F]FDG PET/CT were observed among the cohorts according to gender, pathological stage, T stage, status of LNs, and differentiation (all P > 0.05). The SUV LN differed significantly between the pathological stages and status of LNs both on [ 18 F]Alfatide PET/CT (P = 0.03, 0.003) and [ 18 F]FDG PET/CT (P = 0.001. < 0.001), but not according to gender (P = 0.128, 0.129), T stage (P = 0.791, 0.727), or tumor differentiation (P = 0.049, 0.053). Significant positive correlations were observed between the SUV LN on [ 18 F]Alfatide PET/CT and [ 18 F]FDG PET/CT, and pathological stage (r = 0

  14. Prospective study of serial 18F-FDG PET and 18F-fluoride (18F-NaF) PET to predict time to skeletal related events, time-to-progression, and survival in patients with bone-dominant metastatic breast cancer.

    PubMed

    Peterson, Lanell M; O'Sullivan, Janet; Wu, Qian Vicky; Novakova-Jiresova, Alena; Jenkins, Isaac; Lee, Jean H; Shields, Andrew; Montgomery, Susan; Linden, Hannah M; Gralow, Julie R; Gadi, Vijayakrishna K; Muzi, Mark; Kinahan, Paul E; Mankoff, David A; Specht, Jennifer M

    2018-05-10

    Assessing therapy response of breast cancer bone metastases is challenging. In retrospective studies, serial 18 F-FDG PET was predictive of time to skeletal related events (tSRE) and time-to-progression (TTP). 18 F-NaF PET improves bone metastasis detection compared to bone scans. We prospectively tested 18 F-FDG PET and 18 F-NaF PET to predict tSRE, TTP, and overall survival (OS) in patients with bone-dominant metastatic breast cancer (BD MBC). Methods: Patients with BD MBC were imaged with 18 F-FDG PET and 18 F-NaF PET prior to starting new therapy (scan1) and again at a range of times centered around approximately 4 months later (scan2). SUV max and SULpeak were recorded for a single index lesion and up to 5 most dominant lesions for each scan. tSRE, TTP, and OS were assessed exclusive of the PET images. Univariate Cox regression was performed to test the association between clinical endpoints and 18 F-FDG PET and 18 F-NaF PET measures. mPERCIST (Modified PET Response Criteria in Solid Tumors) criteria were also applied. Survival curves for mPERCIST compared response categories of Complete Response+Partial Response+Stable Disease versus Progressive Disease (CR+PR+SD vs PD) for tSRE, TTP, and OS. Results: Twenty-eight patients were evaluated. Higher FDG SULpeak at scan2 predicted shorter time to tSRE ( P = <0.001) and TTP ( P = 0.044). Higher FDG SUV max at scan2 predicted a shorter time to tSRE ( P = <0.001). A multivariable model using FDG SUV max of the index lesion at scan1 plus the difference in SUV max of up to 5 lesions between scans was predictive for tSRE and TTP. Among 24 patients evaluable by 18 F-FDG PET mPERCIST, tSRE and TTP were longer in responders (CR, PR, or stable) compared to non-responders (PD) ( P = 0.007, 0.028 respectively), with a trend toward improved survival ( P = 0.1). An increase in the uptake between scans of up to 5 lesions by 18 F-NaF PET was associated with longer OS ( P = 0.027). Conclusion: Changes in 18 F-FDG PET parameters

  15. A novel radiochemical approach to 1-(2'-deoxy-2'-[(18) F]fluoro-β-d-arabinofuranosyl)cytosine ((18) F-FAC).

    PubMed

    Meyer, Jan-Philip; Probst, Katrin C; Trist, Iuni M L; McGuigan, Christopher; Westwell, Andrew D

    2014-09-01

    (18) F-FAC (1-(2'-deoxy-2'-[(18) F]fluoro-β-D-arabinofuranosyl)-cytosine) is an important 2'-fluoro-nucleoside-based positron emission tomography (PET) tracer that has been used for in vivo prediction of response to the widely used cancer chemotherapy drug gemcitabine. Previously reported synthetic routes to (18) F-FAC have relied on early introduction of the (18) F radiolabel prior to attachment to protected cytosine base. Considering the (18) F radiochemical half-life (110 min) and the technical challenges of multi-step syntheses on PET radiochemistry modular systems, late-stage radiofluorination is preferred for reproducible and reliable radiosynthesis with in vivo applications. Herein, we report the first late-stage radiosynthesis of (18) F-FAC. Cytidine derivatives with leaving groups at the 2'-position are particularly prone to undergo anhydro side-product formation upon heating because of their electron density at the 2-carbonyl pyrimidone oxygen. Our rationally developed fluorination precursor showed an improved reactivity-to-stability ratio at elevated temperatures. (18) F-FAC was obtained in radiochemical yields of 4.3-5.5% (n = 8, decay-corrected from end of bombardment), with purities ≥98% and specific activities ≥63 GBq/µmol. The synthesis time was 168 min. Copyright © 2014 John Wiley & Sons, Ltd.

  16. Monitoring of anti-cancer treatment with 18F-FDG and 18F-FLT PET: a comprehensive review of pre-clinical studies

    PubMed Central

    Jensen, Mette Munk; Kjaer, Andreas

    2015-01-01

    Functional imaging of solid tumors with positron emission tomography (PET) imaging is an evolving field with continuous development of new PET tracers and discovery of new applications for already implemented PET tracers. During treatment of cancer patients, a general challenge is to measure treatment effect early in a treatment course and by that to stratify patients into responders and non-responders. With 2-deoxy-2-[18F]fluoro-D-glucose (18F-FDG) and 3’-deoxy-3’-[18F]fluorothymidine(18F-FLT) two of the cancer hallmarks, altered energy metabolism and increased cell proliferation, can be visualized and quantified non-invasively by PET. With 18F-FDG and 18F-FLT PET changes in energy metabolism and cell proliferation can thereby be determined after initiation of cancer treatment in both clinical and pre-clinical studies in order to predict, at an early time-point, treatment response. It is hypothesized that decreases in glycolysis and cell proliferation may occur in tumors that are sensitive to the applied cancer therapeutics and that tumors that are resistant to treatment will show unchanged glucose metabolism and cell proliferation. Whether 18F-FDG and/or 18F-FLT PET can be used for prediction of treatment response has been analyzed in many studies both following treatment with conventional chemotherapeutic agents but also following treatment with different targeted therapies, e.g. monoclonal antibodies and small molecules inhibitors. The results from these studies have been most variable; in some studies early changes in 18F-FDG and 18F-FLT uptake predicted later tumor regression whereas in other studies no change in tracer uptake was observed despite the treatment being effective. The present review gives an overview of pre-clinical studies that have used 18F-FDG and/or 18F-FLT PET for response monitoring of cancer therapeutics. PMID:26550536

  17. TMSOTf assisted synthesis of 2’-deoxy-2’-[18F]fluoro-β-D-arabinofuranosylcytosine ([18F]FAC)

    PubMed Central

    Humm, John L.; Larson, Steven M.; Pillarsetty, Naga Vara Kishore

    2018-01-01

    [18F]FAC (2’-deoxy-2’-[18F]fluoro-β-D-arabinofuranosylcytosine, 1) is a versatile probe for imaging deoxycytidine kinase (dCK) expression levels in vivo. dCK is responsible for phosphorylation of deoxycytidine (dC, 2) and other nucleoside analogs, plays a key role in immune activation and has demonstrated to be one of the key enzymes in activating nucleoside based drugs including gemcitabine. Reported synthesis of [18F]FAC is high yielding but is quite challenging requiring bromination using HBr and careful drying of excess HBr which is critical for successful synthesis. Here in we report a simplified trimethylsilyl trifluoromethanesulfonate (TMSOTf) assisted synthesis of [18F]FAC eliminating the need of bromination and drying. [18F]FAC (β-anomer) was synthesized with average isolated decay corrected yield of 10.59 + 4.2% (n = 6) with radiochemical purity of >98% and total synthesis time of 158 + 19 min. PMID:29715301

  18. Conformationally Strained trans-Cyclooctene (sTCO) Enables the Rapid Construction of 18F-PET Probes via Tetrazine Ligation

    PubMed Central

    Wang, Mengzhe; Svatunek, Dennis; Rohlfing, Katarina; Liu, Yu; Wang, Hui; Giglio, Ben; Yuan, Hong; Wu, Zhanghong; Li, Zibo; Fox, Joseph

    2016-01-01

    The bioorthogonal reaction between tetrazines and trans-cyclooctenes is a method for the rapid construction of F-18 probes for PET imaging. Described here is a second generation 18F-labeling system based on a conformationally strained trans-cyclooctene (sTCO)—a dienophile that is approximately 2 orders of magnitude more reactive than conventional TCO dienophiles. Starting from a readily prepared tosylate precursor, an 18F labeled sTCO derivative (18F-sTCO) could be synthesized in 29.3 +/- 5.1% isolated yield and with high specific activity. Tetrazine ligation was carried out with a cyclic RGD-conjugate of a diphenyl-s-tetrazine analogue (RGD-Tz) chosen from a diene class with an excellent combination of fast reactivity and stability both for the diene as well as the Diels-Alder adduct. For both the tetrazine and the sTCO, mini-PEG spacers were included to enhance solubility and improve the in vivo distribution profile of the resulting probe. Extremely fast reactivity (up to 2.86 x 105 M-1s-1 at 25 °C in water) has been observed in kinetic studies in the reaction of sTCO with diphenyl-s-tetrazine derivatives. A kinetic study on sTCO diastereomers in 55:45 MeOH:water showed that the syn-diastereomer displayed slightly faster reactivity than the anti-diastereomer. An 18F-sTCO conjugate with RGD-Tz demonstrated prominent and persistent tumor uptake in vivo with good tumor-to-background contrast. Unlike most radiolabeled RGD peptides, the tumor uptake of this PET agent increased from 5.3 +/- 0.2% ID/g at 1 h post injection (p.i.), to 8.9 +/- 0.5% ID/g at 4 h p.i., providing evidence for prolonged blood circulation. These findings suggest that tetrazine ligations employing 18F-sTCO should serve as a powerful and general platform for the rapid construction of peptide or protein derived PET agents. PMID:27162558

  19. High susceptibility prevalence for F4+ and F18+Escherichia coli in Flemish pigs.

    PubMed

    Nguyen, Ut V; Coddens, Annelies; Melkebeek, Vesna; Devriendt, Bert; Goetstouwers, Tiphanie; Poucke, Mario Van; Peelman, Luc; Cox, Eric

    2017-04-01

    F4 and/or F18 enterotoxigenic Escherichia coli (F4 + /F18 + ETEC) are responsible for diarrhea while F18 + verotoxigenic E. coli (F18 + VTEC) cause edema disease in pigs. Both infections can result in severe economic losses, which are mainly the result of the medication, growth retardation and mortality. The susceptibility of piglets to these pathogens is determined by the presence of F4 and F18 receptors (F4R and F18R). Understanding the composition of the susceptibility phenotypes of pigs is useful for animal health and breeding management. This study aimed to determine the prevalence of the F4 ETEC susceptibility phenotypes and F18 + E. coli susceptibility among Flemish pig breeds by using the in vitro villous adhesion assay. In this study, seven F4 ETEC susceptibility phenotypes were found, namely A (F4 ab R + , ac R + , ad R + ; 59.16%), B (F4 ab R + , ac R + , ad R - ; 6.28%), C (F4 ab R + , ac R - , ad R + ; 2.62%), D (F4 ab R - , ac R - , ad R + ; 6.28%), E (F4 ab R - , ac R - , ad R - ; 24.08%), F (F4 ab R + , ac R - , ad R - ; 1.05%) and G (F4 ab R - , ac R + , ad R - ; 0.52%). F4ab and F4ac E. coli showed a stronger degree of adhesion to the intestinal villi (53.40% and 52.88% strong adhesion, respectively), compared to F4ad E. coli (43.46% strong adhesion). Furthermore, the correlation between F4ac and F4ab adhesion was higher (r=0.78) than between F4ac and F4ad adhesion (r=0.41) and between F4ab and F4ad adhesion (r=0.57). For F18 + E. coli susceptibility, seven out of 82 pigs were F18R negative (8.54%), but only two of these seven pigs (2.44%) were also negative for F4R. As such, the chance to identify a pig that is positive for a F4 ETEC variant or F18 + E. coli is 97.56%. Therefore, significant economic losses will arise due to F4 + and/or F18 + E. coli infections in the Flemish pig population due to the high susceptibility prevalence. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Flexible scintillator autoradiography for tumor margin inspection using 18F-FDG

    NASA Astrophysics Data System (ADS)

    Vyas, K. N.; Grootendorst, M.; Mertzanidou, T.; Macholl, S.; Stoyanov, D.; Arridge, S. R.; Tuch, D. S.

    2018-03-01

    Autoradiography potentially offers high molecular sensitivity and spatial resolution for tumor margin estimation. However, conventional autoradiography requires sectioning the sample which is destructive and labor-intensive. Here we describe a novel autoradiography technique that uses a flexible ultra-thin scintillator which conforms to the sample surface. Imaging with the flexible scintillator enables direct, high-resolution and high-sensitivity imaging of beta particle emissions from targeted radiotracers. The technique has the potential to identify positive tumor margins in fresh unsectioned samples during surgery, eliminating the processing time demands of conventional autoradiography. We demonstrate the feasibility of the flexible autoradiography approach to directly image the beta emissions from radiopharmaceuticals using lab experiments and GEANT-4 simulations to determine i) the specificity for 18F compared to 99mTc-labeled tracers ii) the sensitivity to detect signal from various depths within the tissue. We found that an image resolution of 1.5 mm was achievable with a scattering background and we estimate a minimum detectable activity concentration of 0.9 kBq/ml for 18F. We show that the flexible autoradiography approach has high potential as a technique for molecular imaging of tumor margins using 18F-FDG in a tumor xenograft mouse model imaged with a radiation-shielded EMCCD camera. Due to the advantage of conforming to the specimen, the flexible scintillator showed significantly better image quality in terms of tumor signal to whole-body background noise compared to rigid and optimally thick CaF2:Eu and BC400. The sensitivity of the technique means it is suitable for clinical translation.

  1. Synthesis of [ 18F]arenes via the copper-mediated [ 18F]fluorination of boronic acids

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mossine, Andrew V.; Brooks, Allen F.; Makaravage, Katarina J.

    Here, a copper-mediated radiofluorination of aryl- and vinylboronic acids with K 18F is described. This method exhibits high functional group tolerance and is effective for the radiofluorination of a range of electron-deficient, -neutral, and -rich aryl-, heteroaryl-, and vinylboronic acids. This method has been applied to the synthesis of [ 18F]FPEB, a PET radiotracer for quantifying metabotropic glutamate 5 receptors.

  2. Synthesis of [ 18F]arenes via the copper-mediated [ 18F]fluorination of boronic acids

    DOE PAGES

    Mossine, Andrew V.; Brooks, Allen F.; Makaravage, Katarina J.; ...

    2015-11-14

    Here, a copper-mediated radiofluorination of aryl- and vinylboronic acids with K 18F is described. This method exhibits high functional group tolerance and is effective for the radiofluorination of a range of electron-deficient, -neutral, and -rich aryl-, heteroaryl-, and vinylboronic acids. This method has been applied to the synthesis of [ 18F]FPEB, a PET radiotracer for quantifying metabotropic glutamate 5 receptors.

  3. Detection of Atherosclerotic Inflammation by 68Ga-DOTATATE PET Compared to [18F]FDG PET Imaging.

    PubMed

    Tarkin, Jason M; Joshi, Francis R; Evans, Nicholas R; Chowdhury, Mohammed M; Figg, Nichola L; Shah, Aarti V; Starks, Lakshi T; Martin-Garrido, Abel; Manavaki, Roido; Yu, Emma; Kuc, Rhoda E; Grassi, Luigi; Kreuzhuber, Roman; Kostadima, Myrto A; Frontini, Mattia; Kirkpatrick, Peter J; Coughlin, Patrick A; Gopalan, Deepa; Fryer, Tim D; Buscombe, John R; Groves, Ashley M; Ouwehand, Willem H; Bennett, Martin R; Warburton, Elizabeth A; Davenport, Anthony P; Rudd, James H F

    2017-04-11

    Inflammation drives atherosclerotic plaque rupture. Although inflammation can be measured using fluorine-18-labeled fluorodeoxyglucose positron emission tomography ([ 18 F]FDG PET), [ 18 F]FDG lacks cell specificity, and coronary imaging is unreliable because of myocardial spillover. This study tested the efficacy of gallium-68-labeled DOTATATE ( 68 Ga-DOTATATE), a somatostatin receptor subtype-2 (SST 2 )-binding PET tracer, for imaging atherosclerotic inflammation. We confirmed 68 Ga-DOTATATE binding in macrophages and excised carotid plaques. 68 Ga-DOTATATE PET imaging was compared to [ 18 F]FDG PET imaging in 42 patients with atherosclerosis. Target SSTR2 gene expression occurred exclusively in "proinflammatory" M1 macrophages, specific 68 Ga-DOTATATE ligand binding to SST 2 receptors occurred in CD68-positive macrophage-rich carotid plaque regions, and carotid SSTR2 mRNA was highly correlated with in vivo 68 Ga-DOTATATE PET signals (r = 0.89; 95% confidence interval [CI]: 0.28 to 0.99; p = 0.02). 68 Ga-DOTATATE mean of maximum tissue-to-blood ratios (mTBR max ) correctly identified culprit versus nonculprit arteries in patients with acute coronary syndrome (median difference: 0.69; interquartile range [IQR]: 0.22 to 1.15; p = 0.008) and transient ischemic attack/stroke (median difference: 0.13; IQR: 0.07 to 0.32; p = 0.003). 68 Ga-DOTATATE mTBR max predicted high-risk coronary computed tomography features (receiver operating characteristics area under the curve [ROC AUC]: 0.86; 95% CI: 0.80 to 0.92; p < 0.0001), and correlated with Framingham risk score (r = 0.53; 95% CI: 0.32 to 0.69; p <0.0001) and [ 18 F]FDG uptake (r = 0.73; 95% CI: 0.64 to 0.81; p < 0.0001). [ 18 F]FDG mTBR max differentiated culprit from nonculprit carotid lesions (median difference: 0.12; IQR: 0.0 to 0.23; p = 0.008) and high-risk from lower-risk coronary arteries (ROC AUC: 0.76; 95% CI: 0.62 to 0.91; p = 0.002); however, myocardial [ 18 F]FDG spillover rendered coronary

  4. 18F-Fluorodeoxyglucose Positron Emission Tomography/Magnetic Resonance in Lymphoma

    PubMed Central

    Giraudo, Chiara; Raderer, Markus; Karanikas, Georgios; Weber, Michael; Kiesewetter, Barbara; Dolak, Werner; Simonitsch-Klupp, Ingrid; Mayerhoefer, Marius E.

    2016-01-01

    Objectives The aim of this study was to compare 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/magnetic resonance (MR) (with and without diffusion-weighted imaging [DWI]) to 18F-FDG PET/computed tomography (CT), with regard to the assessment of nodal and extranodal involvement, in patients with Hodgkin lymphoma and non-Hodgkin lymphoma, without restriction to FDG-avid subytpes. Materials and Methods Patients with histologically proven lymphoma were enrolled in this prospective, institutional review board–approved study. After a single 18F-FDG injection, patients consecutively underwent 18F-FDG PET⁄CT and 18F-FDG PET/MR on the same day for staging or restaging. Three sets of images were analyzed separately: 18F-FDG PET/CT, 18F-FDG PET/MR without DWI, and 18F-FDG PET/MR with DWI. Region-based agreement and examination-based sensitivity and specificity were calculated for 18F-FDG PET/CT, 18F-FDG PET/MR without DWI, and 18F-FDG PET/MR DWI. Maximum and mean standardized uptake values (SUVmax, SUVmean) on 18F-FDG PET/CT and 18F-FDG PET/MR were compared and correlated with minimum and mean apparent diffusion coefficients (ADCmin, ADCmean). Results Thirty-four patients with a total of 40 examinations were included. Examination-based sensitivities for 18F-FDG PET/CT, 18F-FDG PET/MR, and 18F-FDG PET/MR DWI were 82.1%, 85.7%, and 100%, respectively; specificities were 100% for all 3 techniques; and accuracies were 87.5%, 90%, and 100%, respectively. 18F-FDG PET/CT was false negative in 5 of 40 examinations (all with mucosa-associated lymphoid tissue lymphoma), and 18F-FDG PET/MR (without DWI) was false negative in 4 of 40 examinations. Region-based percentages of agreement were 99% (κ, 0.95) between 18F-FDG PET/MR DWI and 18F-FDG PET/CT, 99.2% (κ, 0.96) between 18F-FDG PET/MR and 18F-FDG PET/CT, and 99.4% (κ, 0.97) between 18F-FDG PET/MR DWI and 18F-FDG PET/MR. There was a strong correlation between 18F-FDG PET/CT and 18F-FDG PET/MR for SUVmax (r = 0

  5. Multidentate (18)F-polypegylated styrylpyridines as imaging agents for Aβ plaques in cerebral amyloid angiopathy (CAA).

    PubMed

    Zha, Zhihao; Choi, Seok Rye; Ploessl, Karl; Lieberman, Brian P; Qu, Wenchao; Hefti, Franz; Mintun, Mark; Skovronsky, Daniel; Kung, Hank F

    2011-12-08

    β-Amyloid plaques (Aβ plaques) in the brain are associated with cerebral amyloid angiopathy (CAA). Imaging agents that could target the Aβ plaques in the living human brain would be potentially valuable as biomarkers in patients with CAA. A new series of (18)F styrylpyridine derivatives with high molecular weights for selectively targeting Aβ plaques in the blood vessels of the brain but excluded from the brain parenchyma is reported. The styrylpyridine derivatives, 8a-c, display high binding affinities and specificity to Aβ plaques (K(i) = 2.87, 3.24, and 7.71 nM, respectively). In vitro autoradiography of [(18)F]8a shows labeling of β-amyloid plaques associated with blood vessel walls in human brain sections of subjects with CAA and also in the tissue of AD brain sections. The results suggest that [(18)F]8a may be a useful PET imaging agent for selectively detecting Aβ plaques associated with cerebral vessels in the living human brain.

  6. Combined early dynamic (18)F-FDG PET/CT and conventional whole-body (18)F-FDG PET/CT provide one-stop imaging for detecting hepatocellular carcinoma.

    PubMed

    Wang, Shao-Bo; Wu, Hu-Bing; Wang, Quan-Shi; Zhou, Wen-Lan; Tian, Ying; Li, Hong-Sheng; Ji, Yun-Hai; Lv, Liang

    2015-06-01

    It is widely accepted that conventional (18)F-FDG PET/CT (whole-body static (18)F-FDG PET/CT, WB (18)F-FDG PET/CT) has a low detection rate for hepatocellular carcinoma (HCC). We prospectively assessed the role of early dynamic (18)F-FDG PET/CT (ED (18)F-FDG PET/CT) and WB (18)F-FDG PET/CT in detecting HCC, and we quantified the added value of ED (18)F-FDG PET/CT to WB (18)F-FDG PET/CT. Twenty-two patients with 37 HCC tumors (HCCs) who underwent both a liver ED (18)F-FDG PET/CT (performed simultaneously with a 5.5 MBq/kg (18)F-FDG bolus injection and continued for 240 s) and a WB (18)F-FDG PET/CT were enrolled in the study. The WB (18)F-FDG PET/CT and ED (18)F-FDG PET/CT scans were positive in 56.7% (21/37) and 78.4% (29/37) HCCs, respectively (P<0.05). ED (18)F-FDG PET/CT in conjunction with WB (18)F-FDG PET/CT (one-stop (18)F-FDG PET/CT) improved the positive detection rates of WB and ED (18)F-FDG PET/CT alone from 56.7% and 78.4% to 91.9% (34/37) (P<0.001 and P>0.05, respectively). One-stop (18)F-FDG PET/CT appears to be useful to improve WB (18)F-FDG PET/CT for HCC detection. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  7. Accuracy of 18F-FDOPA Positron Emission Tomography and 18F-FET Positron Emission Tomography for Differentiating Radiation Necrosis from Brain Tumor Recurrence.

    PubMed

    Yu, Jun; Zheng, Jingwei; Xu, Weilin; Weng, Jiaqi; Gao, Liansheng; Tao, Li; Liang, Feng; Zhang, Jianmin

    2018-06-01

    Distinguishing radiation necrosis from brain tumor recurrence remains challenging. We performed a meta-analysis to assess the diagnostic accuracy of 2 different amino acid tracers used in positron emission tomography/computed tomography scans: 18 F-FDOPA (6-[18F]-fluoro-L-3,4-dihydroxyphenylalanine) and 18 F-FET (O-(2-18F-fluoroethyl)-L-tyrosine). We searched for studies in 3 databases: PubMed, Embase, and Chinese Biomedical databases. The data were extracted from eligible studies and then processed with heterogeneity test, threshold effect test, and calculations of sensitivity, specificity, and area under the summary receiver operating characteristic curve. Meta-regression and subgroup analyses were performed to explore the source of heterogeneity. A total of 48 studies ( 18 F-FDOPA, n = 21; 18 F-FET, n = 27) were included. Quantitative synthesis determined pooled weight values in the 18 F-FDOPA and 18 F-FET groups: sensitivity, 0.85 versus 0.82; specificity, 0.77 versus 0.80; diagnostic odds ratio, 21.7 versus 23.03; area under the curve (AUC) values, 0.8771 versus 0.8976 (P = 0.46). Moreover, the type of tumor was identified as the possible source of the significant heterogeneity (I 2  = 52%; P = 0.003) found in the 18 F-FDOPA group. In meta-regression and subgroup analyses, 18 F-FDOPA showed better diagnostic accuracy in patients with glioma compared with patients with brain metastases (AUC values, 0.9691 vs. 0.837; P < 0.01). 18 F-FDOPA also showed a significant advantage in the diagnosis of glioma recurrence compared with 18 F-FET (AUC values, 0.9691 vs. 0.9124; P = 0.015). Both 18 F-FDOPA and 18 F-FET exhibit moderate overall accuracy in diagnosing brain tumor recurrence from radiation necrosis. However, 18 F-FDOPA is more adept at diagnosing glioma recurrence compared with brain metastases, and it is more effective than 18 F-FET in diagnosing glioma recurrence. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. Comparison of 68Ga-DOTA-Siglec-9 and 18F-Fluorodeoxyribose-Siglec-9: Inflammation Imaging and Radiation Dosimetry.

    PubMed

    Virtanen, Helena; Silvola, Johanna M U; Autio, Anu; Li, Xiang-Guo; Liljenbäck, Heidi; Hellberg, Sanna; Siitonen, Riikka; Ståhle, Mia; Käkelä, Meeri; Airaksinen, Anu J; Helariutta, Kerttuli; Tolvanen, Tuula; Veres, Tibor Z; Saraste, Antti; Knuuti, Juhani; Jalkanen, Sirpa; Roivainen, Anne

    2017-01-01

    Sialic acid-binding immunoglobulin-like lectin 9 (Siglec-9) is a ligand of inflammation-inducible vascular adhesion protein-1 (VAP-1). We compared 68 Ga-DOTA- and 18 F-fluorodeoxyribose- (FDR-) labeled Siglec-9 motif peptides for PET imaging of inflammation. Methods . Firstly, we examined 68 Ga-DOTA-Siglec-9 and 18 F-FDR-Siglec-9 in rats with skin/muscle inflammation. We then studied 18 F-FDR-Siglec-9 for the detection of inflamed atherosclerotic plaques in mice and compared it with previous 68 Ga-DOTA-Siglec-9 results. Lastly, we estimated human radiation dosimetry from the rat data. Results . In rats, 68 Ga-DOTA-Siglec-9 (SUV, 0.88 ± 0.087) and 18 F-FDR-Siglec-9 (SUV, 0.77 ± 0.22) showed comparable ( P = 0.29) imaging of inflammation. In atherosclerotic mice, 18 F-FDR-Siglec-9 detected inflamed plaques with a target-to-background ratio (1.6 ± 0.078) similar to previously tested 68 Ga-DOTA-Siglec-9 ( P = 0.35). Human effective dose estimates for 68 Ga-DOTA-Siglec-9 and 18 F-FDR-Siglec-9 were 0.024 and 0.022 mSv/MBq, respectively. Conclusion . Both tracers are suitable for PET imaging of inflammation. The easier production and lower cost of 68 Ga-DOTA-Siglec-9 present advantages over 18 F-FDR-Siglec-9, indicating it as a primary choice for clinical studies.

  9. Prospective Comparison of 99mTc-MDP Scintigraphy, Combined 18F-NaF and 18F-FDG PET/CT, and Whole-Body MRI in Patients with Breast and Prostate Cancer.

    PubMed

    Minamimoto, Ryogo; Loening, Andreas; Jamali, Mehran; Barkhodari, Amir; Mosci, Camila; Jackson, Tatianie; Obara, Piotr; Taviani, Valentina; Gambhir, Sanjiv Sam; Vasanawala, Shreyas; Iagaru, Andrei

    2015-12-01

    We prospectively evaluated the use of combined (18)F-NaF/(18)F-FDG PET/CT in patients with breast and prostate cancer and compared the results with those for (99m)Tc-MDP bone scintigraphy and whole-body MRI. Thirty patients (15 women with breast cancer and 15 men with prostate cancer) referred for standard-of-care bone scintigraphy were prospectively enrolled in this study. (18)F-NaF/(18)F-FDG PET/CT and whole-body MRI were performed after bone scintigraphy. The whole-body MRI protocol consisted of both unenhanced and contrast-enhanced sequences. Lesions detected with each test were tabulated, and the results were compared. For extraskeletal lesions, (18)F-NaF/(18)F-FDG PET/CT and whole-body MRI had no statistically significant differences in sensitivity (92.9% vs. 92.9%, P = 1.00), positive predictive value (81.3% vs. 86.7%, P = 0.68), or accuracy (76.5% vs. 82.4%, P = 0.56). However, (18)F-NaF/(18)F-FDG PET/CT showed significantly higher sensitivity and accuracy than whole-body MRI (96.2% vs. 81.4%, P < 0.001, 89.8% vs. 74.7%, P = 0.01) and bone scintigraphy (96.2% vs. 64.6%, P < 0.001, 89.8% vs. 65.9%, P < 0.001) for the detection of skeletal lesions. Overall, (18)F-NaF/(18)F-FDG PET/CT showed higher sensitivity and accuracy than whole-body MRI (95.7% vs. 83.3%, P < 0.002, 87.6% vs. 76.0%, P < 0.02) but not statistically significantly so when compared with a combination of whole-body MRI and bone scintigraphy (95.7% vs. 91.6%, P = 0.17, 87.6% vs. 83.0%, P = 0.53). (18)F-NaF/(18)F-FDG PET/CT showed no significant difference from a combination of (18)F-NaF/(18)F-FDG PET/CT and whole-body MRI. No statistically significant differences in positive predictive value were noted among the 3 examinations. (18)F-NaF/(18)F-FDG PET/CT is superior to whole-body MRI and (99m)Tc-MDP scintigraphy for evaluation of skeletal disease extent. Further, (18)F-NaF/(18)F-FDG PET/CT and whole-body MRI detected extraskeletal disease that may change the management of these patients. (18)F-NaF

  10. Optimization of automated large-scale production of [(18)F]fluoroethylcholine for PET prostate cancer imaging.

    PubMed

    Pascali, Giancarlo; D'Antonio, Luca; Bovone, Paola; Gerundini, Paolo; August, Thorsten

    2009-07-01

    PET tumor imaging is gaining importance in current clinical practice. FDG-PET is the most utilized approach but suffers from inflammation influences and is not utilizable in prostate cancer detection. Recently, (11)C-choline analogues have been employed successfully in this field of imaging, leading to a growing interest in the utilization of (18)F-labeled analogues: [(18)F]fluoroethylcholine (FEC) has been demonstrated to be promising, especially in prostate cancer imaging. In this work we report an automatic radiosynthesis of this tracer with high yields, short synthesis time and ease of performance, potentially utilizable in routine production sites. We used a Modular Lab system to automatically perform the two-step/one-pot synthesis. In the first step, we labeled ethyleneglycolditosylate obtaining [(18)F]fluoroethyltosylate; in the second step, we performed the coupling of the latter intermediate with neat dimethylethanolamine. The final mixture was purified by means of solid phase extraction; in particular, the product was trapped into a cation-exchange resin and eluted with isotonic saline. The optimized procedure resulted in a non decay corrected yield of 36% and produced a range of 30-45 GBq of product already in injectable form. The product was analyzed for quality control and resulted as pure and sterile; in addition, residual solvents were under the required threshold. In this work, we present an automatic FEC radiosynthesis that has been optimized for routine production. This findings should foster the interest for a wider utilization of this radiomolecule for imaging of prostate cancer with PET, a field for which no gold-standard tracer has yet been validated.

  11. Novel radiosynthesis of PET HSV-tk gene reporter probes [18F]FHPG and [18F]FHBG employing dual Sep-Pak SPE techniques.

    PubMed

    Wang, Ji-Quan; Zheng, Qi-Huang; Fei, Xiangshu; Mock, Bruce H; Hutchins, Gary D

    2003-11-17

    Positron emission tomography (PET) herpes simplex virus thymidine kinase (HSV-tk) gene reporter probes 9-[(3-[(18)F]fluoro-1-hydroxy-2-propoxy)methyl]guanine ([(18)F]FHPG) and 9-(4-[(18)F]fluoro-3-hydroxymethylbutyl)guanine ([(18)F]FHBG) were prepared by nucleophilic substitution of the appropriate tosylated precursors with [(18)F]KF/Kryptofix 2.2.2 followed by a quick deprotection reaction and purification with a simplified dual Silica Sep-Pak solid-phase extraction (SPE) method in 15-30% radiochemical yield.

  12. Improved synthesis of [(18)F]FLETT via a fully automated vacuum distillation method for [(18)F]2-fluoroethyl azide purification.

    PubMed

    Ackermann, Uwe; Plougastel, Lucie; Goh, Yit Wooi; Yeoh, Shinn Dee; Scott, Andrew M

    2014-12-01

    The synthesis of [(18)F]2-fluoroethyl azide and its subsequent click reaction with 5-ethynyl-2'-deoxyuridine (EDU) to form [(18)F]FLETT was performed using an iPhase FlexLab module. The implementation of a vacuum distillation method afforded [(18)F]2-fluoroethyl azide in 87±5.3% radiochemical yield. The use of Cu(CH3CN)4PF6 and TBTA as catalyst enabled us to fully automate the [(18)F]FLETT synthesis without the need for the operator to enter the radiation field. [(18)F]FLETT was produced in higher overall yield (41.3±6.5%) and shorter synthesis time (67min) than with our previously reported manual method (32.5±2.5% in 130min). Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. ^2H(^18F,p)^19F Study at 6 MeV/u

    NASA Astrophysics Data System (ADS)

    Kozub, R. L.; Nesaraja, C. D.; Moazen, B. H.; Scott, J. P.; Bardayan, D. W.; Blackmon, J. C.; Gross, C. J.; Shapira, D.; Smith, M. S.; Batchelder, J. C.; Brune, C. R.; Champagne, A. E.; Sahin, L.; Cizewski, J. A.; Thomas, J. S.; Davinson, T.; Woods, P. J.; Greife, U.; Jewett, C.; Livesay, R. J.; Ma, Z.; Parker, P. D.

    2003-04-01

    The degree to which the (p,α) and (p,γ) reactions destroy ^18F at temperatures ˜1-4 x 10^8 K is important for understanding the synthesis of nuclei in nova explosions and for using ^18F as a monitor of nova mechanisms in gamma ray astronomy. The reactions are dominated by low-lying proton resonances near the ^18F+p threshold (E_x=6.411 MeV excitation energy in ^19Ne). To gain further information about these resonances, we have used the inverse ^18F(d,p)^19F neutron transfer reaction at the Holifield Radioactive Ion Beam Facility to selectively populate corresponding mirror states in ^19F. Proton angular distributions were measured for states in ^19F in the excitation energy range 0-9 MeV. Results and implications for the ^18F+p reactions and nuclear structure will be presented. ^1Supported by DOE. ^2ORNL is managed by UT-Battelle, LLC, for the USDOE.

  14. Development of two fluorine-18 labeled PET radioligands targeting PDE10A and in vivo PET evaluation in nonhuman primates.

    PubMed

    Stepanov, Vladimir; Takano, Akihiro; Nakao, Ryuji; Amini, Nahid; Miura, Shotaro; Hasui, Tomoaki; Kimura, Haruhide; Taniguchi, Takahiko; Halldin, Christer

    2018-02-01

    Phosphodiesterase 10A (PDE10A) is a member of the PDE enzyme family that degrades cyclic adenosine and guanosine monophosphates (cAMP and cGMP). Based on the successful development of [ 11 C]T-773 as PDE10A positron emission tomography (PET) radioligand, in this study our aim was to develop and evaluate fluorine-18 analogs of [ 11 C]T-773. [ 18 F]FM-T-773-d 2 and [ 18 F]FE-T-773-d 4 were synthesized from the same precursor used for 11 C-labeling of T-773 in a two-step approach via 18 F-fluoromethylation and 18 F-fluoroethylation, respectively, using corresponding deuterated synthons. A total of 12 PET measurements were performed in seven non-human primates. First, baseline PET measurements were performed using High Resolution Research Tomograph system with both [ 18 F]FM-T-773-d 2 and [ 18 F]FE-T-773-d 4 ; the uptake in whole brain and separate brain regions, as well as the specific binding and tissue ratio between putamen and cerebellum, was examined. Second, baseline and pretreatment PET measurements using MP-10 as the blocker were performed for [ 18 F]FM-T-773-d 2 including arterial blood sampling with radiometabolite analysis in four NHPs. Both [ 18 F]FM-T-773-d 2 and [ 18 F]FE-T-773-d 4 were successfully radiolabeled with an average molar activity of 293 ± 114 GBq/μmol (n=8) for [ 18 F]FM-T-773-d 2 and 209 ± 26 GBq/μmol (n=4) for [ 18 F]FE-T-773-d 4 , and a radiochemical yield of 10% (EOB, n=12, range 3%-16%). Both radioligands displayed high brain uptake (~5.5% of injected radioactivity for [ 18 F]FM-T-773-d 2 and ~3.5% for [ 18 F]FE-T-773-d 4 at the peak) and a fast washout. Specific binding reached maximum within 30 min for [ 18 F]FM-T-773-d 2 and after approximately 45 min for [ 18 F]FE-T-773-d 4 . [ 18 F]FM-T-773-d 2 data fitted well with kinetic compartment models. BP ND values obtained indirectly through compartment models were correlated well with those obtained by SRTM. BP ND calculated with SRTM was 1.0-1.7 in the putamen. The occupancy with 1.8

  15. Stereotactic Comparison Study of (18)F-Alfatide and (18)F-FDG PET Imaging in an LLC Tumor-Bearing C57BL/6 Mouse Model.

    PubMed

    Wei, Yu-Chun; Gao, Yongsheng; Zhang, Jianbo; Fu, Zheng; Zheng, Jinsong; Liu, Ning; Hu, Xudong; Hou, Wenhong; Yu, Jinming; Yuan, Shuanghu

    2016-06-28

    This study aimed to stereotactically compare the PET imaging performance of (18)F-Alfatide ((18)F-ALF-NOTA-PRGD2, denoted as (18)F-Alfatide) and (18)F-fluorodeoxyglucose (FDG) and immunohistochemistry (IHC) staining in Lewis lung carcinoma (LLC) tumor-bearing C57BL/6 mouse model. (18)F-FDG standard uptake values (SUVs) were higher than (18)F-Alfatide SUVs in tumors, most of the normal tissues and organs except for the bladder. Tumor-to-brain, tumor-to-lung, and tumor-to-heart ratios of (18)F-Alfatide PET were significantly higher than those of (18)F-FDG PET (P < 0.001). The spatial heterogeneity of the tumors was detected, and the tracer accumulation enhanced from the outer layer to the inner layer consistently using the two tracers. The parameters of the tumors were significantly correlated with each other between (18)F-FDG SUV and GLUT-1 (R = 0.895, P < 0.001), (18)F-Alfatide SUV and αvβ3 (R = 0.595, P = 0.019), (18)F-FDG SUV and (18)F-Alfatide SUV (R = 0.917, P < 0.001), and GLUT-1 and αvβ3 (R = 0.637, P = 0.011). Therefore, (18)F-Alfatide PET may be an effective tracer for tumor detection, spatial heterogeneity imaging and an alternative supplement to (18)F-FDG PET, particularly for patients with enhanced characteristics in the brain, chest tumors or diabetes, meriting further study.

  16. (18)F-FDG and (18)F-FLT PET/CT imaging in the characterization of mediastinal lymph nodes.

    PubMed

    Rayamajhi, Sampanna Jung; Mittal, Bhagwant Rai; Maturu, Venkata Nagarjuna; Agarwal, Ritesh; Bal, Amanjit; Dey, Pranab; Shukla, Jaya; Gupta, Dheeraj

    2016-04-01

    There is currently no single modality for accurate characterization of enlarged mediastinal lymph nodes into benign or malignant. Recently (18)F-fluorothymidine (FLT) has been used as a proliferation marker. In this prospective study, we examined the role of (18)F-fluorodeoxyglucose ((18)F-FDG) positron emission tomography/computed tomography (PET/CT) and (18)F-FLT PET/CT in categorizing mediastinal lymph nodes as benign or malignant. A total of 70 consecutive patients with mediastinal lymphadenopathy detected on computed tomography (CT) or chest radiograph underwent whole body (18)F-FLT PET/CT and (18)F-FDG PET/CT (within 1 week of each other). Lymph nodal tracer uptake was determined by calculation of standardized uptake value (SUV) with both the tracers. Results of PET/CT were compared with histopathology of the lymph nodes. Histopathology results showed thirty-seven patients with sarcoidosis, seven patients with tuberculosis, nine patients with non-small cell lung cancer, five patients with Hodgkin's lymphoma and twelve patients with non-Hodgkin's lymphoma. The mean FDG SUVmax of sarcoidosis, tuberculosis, Hodgkin's and non-Hodgkin's lymphoma was 12.7, 13.4, 8.2, and 8.8, respectively, and the mean FLT SUVmax was 6.0, 5.4, 4.4, and 3.8, respectively. It was not possible to characterize mediastinal lymphadenopathy as benign or malignant solely based on FDG SUVmax values (p > 0.05) or FLT SUVmax values (p > 0.05). There was no significant difference in FDG uptake (p > 0.9) or FLT uptake (p > 0.9) between sarcoidosis and tuberculosis. In lung cancer patients, the FDG SUVmax and FLT SUVmax of those lymph nodes with tumor infiltration on biopsy was 6.7 and 3.9, respectively, and those without nodal infiltration was 6.4 and 3.7, respectively, and both the tracers were not able to characterize the nodal status as malignant or benign (p > 0.05). Though (18)F-FLT PET/CT and (18)F-FDG PET/CT reflect different aspects of biology, i.e., proliferation and metabolism

  17. PET Imaging of Macrophage Mannose Receptor-Expressing Macrophages in Tumor Stroma Using 18F-Radiolabeled Camelid Single-Domain Antibody Fragments.

    PubMed

    Blykers, Anneleen; Schoonooghe, Steve; Xavier, Catarina; D'hoe, Kevin; Laoui, Damya; D'Huyvetter, Matthias; Vaneycken, Ilse; Cleeren, Frederik; Bormans, Guy; Heemskerk, Johannes; Raes, Geert; De Baetselier, Patrick; Lahoutte, Tony; Devoogdt, Nick; Van Ginderachter, Jo A; Caveliers, Vicky

    2015-08-01

    Tumor-associated macrophages constitute a major component of the stroma of solid tumors, encompassing distinct subpopulations with different characteristics and functions. We aimed to identify M2-oriented tumor-supporting macrophages within the tumor microenvironment as indicators of cancer progression and prognosis, using PET imaging. This can be realized by designing (18)F-labeled camelid single-domain antibody fragments (sdAbs) specifically targeting the macrophage mannose receptor (MMR), which has been identified as an important biomarker on this cell population. Cross-reactive anti-MMR sdAbs were generated after immunization of an alpaca with the extracellular domains of both human and mouse MMR. The lead binder was chosen on the basis of comparisons of binding affinity and in vivo pharmacokinetics. The PET tracer (18)F-fluorobenzoate (FB)-anti-MMR sdAb was developed using the prosthetic group N-succinimidyl-4-(18)F-fluorobenzoate ((18)F-SFB), and its biodistribution, tumor-targeting potential, and specificity in terms of macrophage and MMR targeting were evaluated in mouse tumor models. Four sdAbs were selected after affinity screening, but only 2 were found to be cross-reactive for human and mouse MMR. The lead anti-MMR 3.49 sdAb, bearing an affinity of 12 and 1.8 nM for mouse and human MMR, respectively, was chosen for its favorable in vivo biodistribution profile and tumor-targeting capacity. (18)F-FB-anti-MMR 3.49 sdAb was synthesized with a 5%-10% radiochemical yield using an automated and optimized protocol. In vivo biodistribution analyses showed fast clearance via the kidneys and retention in MMR-expressing organs and tumor. The kidney retention of the fluorinated sdAb was 20-fold lower than a (99m)Tc-labeled counterpart. Compared with MMR- and C-C chemokine receptor 2-deficient mice, significantly higher uptake was observed in tumors grown in wild-type mice, demonstrating the specificity of the (18)F tracer for MMR and macrophages, respectively. Anti

  18. Automation of [(18) F]fluoroacetaldehyde synthesis: application to a recombinant human interleukin-1 receptor antagonist (rhIL-1RA).

    PubMed

    Morris, Olivia; McMahon, Adam; Boutin, Herve; Grigg, Julian; Prenant, Christian

    2016-06-15

    [(18) F]Fluoroacetaldehyde is a biocompatible prosthetic group that has been implemented pre-clinically using a semi-automated remotely controlled system. Automation of radiosyntheses permits use of higher levels of [(18) F]fluoride whilst minimising radiochemist exposure and enhancing reproducibility. In order to achieve full-automation of [(18) F]fluoroacetaldehyde peptide radiolabelling, a customised GE Tracerlab FX-FN with fully programmed automated synthesis was developed. The automated synthesis of [(18) F]fluoroacetaldehyde is carried out using a commercially available precursor, with reproducible yields of 26% ± 3 (decay-corrected, n = 10) within 45 min. Fully automated radiolabelling of a protein, recombinant human interleukin-1 receptor antagonist (rhIL-1RA), with [(18) F]fluoroacetaldehyde was achieved within 2 h. Radiolabelling efficiency of rhIL-1RA with [(18) F]fluoroacetaldehyde was confirmed using HPLC and reached 20% ± 10 (n = 5). Overall RCY of [(18) F]rhIL-1RA was 5% ± 2 (decay-corrected, n = 5) within 2 h starting from 35 to 40 GBq of [(18) F]fluoride. Specific activity measurements of 8.11-13.5 GBq/µmol were attained (n = 5), a near three-fold improvement of those achieved using the semi-automated approach. The strategy can be applied to radiolabelling a range of peptides and proteins with [(18) F]fluoroacetaldehyde analogous to other aldehyde-bearing prosthetic groups, yet automation of the method provides reproducibility thereby aiding translation to Good Manufacturing Practice manufacture and the transformation from pre-clinical to clinical production. Copyright © 2016 The Authors. Journal of Labelled Compounds and Radiopharmaceuticals published by John Wiley & Sons, Ltd.

  19. Biodistribution and Radiation Dosimetry of the Enterobacteriaceae-Specific Imaging Probe [(18)F]Fluorodeoxysorbitol Determined by PET/CT in Healthy Human Volunteers.

    PubMed

    Zhu, Wenjia; Yao, Shaobo; Xing, Haiqun; Zhang, Hui; Tai, Yuan-Chuan; Zhang, Yingqiang; Liu, Yimin; Ma, Yanru; Wu, Chenxi; Wang, Hongkai; Li, Zibo; Wu, Zhanhong; Zhu, Zhaohui; Li, Fang; Huo, Li

    2016-10-01

    [(18)F]fluorodeoxysorbitol ([(18)F]FDS) is the first radiopharmaceutical specific for a category of bacteria and has the potential to specifically detect Enterobacteriaceae infections. The purpose of this study was to testify the safety and investigate the biodistribution and radiation dosimetry of [(18)F]FDS in healthy human bodies. Six healthy subjects were intravenously injected with 320-520 MBq [(18)F]FDS. On each subject, 21 whole-body emission scans and a brain scan were conducted at settled time points within the next 4 h. Residence time for each source organ was determined by multi-exponential regression. Absorbed doses for target organs and effective dose were calculated via OLINDA/EXM. No adverse events due to [(18)F]FDS injection were observed in the study. The tracer was cleared rapidly from the blood pool through the urinary system. A small portion was cleared into the gut through the hepatobiliary system. The effective dose (ED) was estimated to be 0.021 ± 0.001 mSv/MBq. The organ receiving the highest absorbed dose was the urinary bladder wall (0.25 ± 0.03 mSv/MBq). [(18)F]FDS is safe and well tolerated. The effective dose was comparable to that of other F-18 labeled radiotracers. [(18)F]FDS is suitable for human use from a radiation dosimetry perspective.

  20. This NASA Dryden F/A-18 is participating in the Automated Aerial Refueling (AAR) project. F/A-18 (No

    NASA Technical Reports Server (NTRS)

    2002-01-01

    A NASA Dryden F/A-18 is participating in the Automated Aerial Refueling (AAR) project. F/A-18 (No. 847) is acting as an in-flight refueling tanker in the study to develop analytical models for an automated aerial refueling system for unmanned vehicles. A 300-gallon aerodynamic pod containing air-refueling equipment is seen beneath the fuselage. The hose and refueling basket are extended during an assessment of their dynamics on the F/A-18A.

  1. Assessment of glucose metabolism and cellular proliferation in multiple myeloma: a first report on combined 18F-FDG and 18F-FLT PET/CT imaging.

    PubMed

    Sachpekidis, C; Goldschmidt, H; Kopka, K; Kopp-Schneider, A; Dimitrakopoulou-Strauss, A

    2018-04-10

    Despite the significant upgrading in recent years of the role of 18 F-FDG PET/CT in multiple myeloma (MM) diagnostics, there is a still unmet need for myeloma-specific radiotracers. 3'-Deoxy-3'-[ 18 F]fluorothymidine ( 18 F-FLT) is the most studied cellular proliferation PET agent, considered a potentially new myeloma functional imaging tracer. The aim of this pilot study was to evaluate 18 F-FLT PET/CT in imaging of MM patients, in the context of its combined use with 18 F-FDG PET/CT. Eight patients, four suffering from symptomatic MM and four suffering from smoldering MM (SMM), were enrolled in the study. All patients underwent 18 F-FDG PET/CT and 18 F-FLT PET/CT imaging by means of static (whole body) and dynamic PET/CT of the lower abdomen and pelvis (dPET/CT) in two consecutive days. The evaluation of PET/CT studies was based on qualitative evaluation, semi-quantitative (SUV) calculation, and quantitative analysis based on two-tissue compartment modeling. 18 F-FDG PET/CT demonstrated focal, 18 F-FDG avid, MM-indicative bone marrow lesions in five patients. In contrary, 18 F-FLT PET/CT showed focal, 18 F-FLT avid, myeloma-indicative lesions in only two patients. In total, 48 18 F-FDG avid, focal, MM-indicative lesions were detected with 18 F-FDG PET/CT, while 17 18 F-FLT avid, focal, MM-indicative lesions were detected with 18 F-FLT PET/CT. The number of myeloma-indicative lesions was significantly higher for 18 F-FDG PET/CT than for 18 F-FLT PET/CT. A common finding was a mismatch of focally increased 18 F-FDG uptake and reduced 18 F-FLT uptake (lower than the surrounding bone marrow). Moreover, 18 F-FLT PET/CT was characterized by high background activity in the bone marrow compartment, further complicating the evaluation of bone marrow lesions. Semi-quantitative evaluation revealed that both SUV mean and SUV max were significantly higher for 18 F-FLT than for 18 F-FDG in both MM lesions and reference tissue. SUV values were higher in MM lesions than in

  2. Equilibrium modeling of 5-HT(2A) receptors with [18F]deuteroaltanserin and PET: feasibility of a constant infusion paradigm.

    PubMed

    van Dyck, C H; Soares, J C; Tan, P Z; Staley, J K; Baldwin, R M; Amici, L A; Fu, X; Garg, P K; Seibyl, J P; Charney, D S; Innis, R B

    2000-11-01

    [(18)F]Altanserin has emerged as a promising positron emission tomography (PET) ligand for serotonin-2A (5-HT(2A)) receptors. The deuterium substitution of both of the 2'-hydrogens of altanserin ([(18)F]deuteroaltanserin) yields a metabolically more stable radiotracer with higher ratios of parent tracer to radiometabolites and increased specific brain uptake than [(18)F]altanserin. The slower metabolism of the deuterated analog might preclude the possibility of achieving stable plasma and brain activities with a bolus plus constant infusion within a reasonable time frame for an (18)F-labeled tracer (T(1/2) 110 min). Thus, the purpose of this study was to test the feasibility in human subjects of a constant infusion paradigm for equilibrium modeling of [(18)F]deuteroaltanserin with PET. Seven healthy male subjects were injected with [(18)F]deuteroaltanserin as a bolus plus constant infusion lasting 10 h postinjection. PET acquisitions and venous blood sampling were performed throughout the infusion period. Linear regression analysis revealed that time-activity curves for both specific brain uptake and plasma [(18)F]deuteroaltanserin concentration stabilized after about 5 h. This permitted equilibrium modeling and estimation of V(')(3) (ratio of specific uptake to total plasma parent concentration) and the binding potential V(3) (ratio of specific uptake to free plasma parent concentration). Cortical/cerebellar ratios were increased by 26% relative to those we previously observed with [(18)F]altanserin using similar methodology in a somewhat older subject sample. These results demonstrate feasibility of equilibrium imaging with [(18)F]deuteroaltanserin and suggest that it may be superior to [(18)F]altanserin as a PET radioligand.

  3. Effects of glucose, insulin, and insulin resistance on cerebral 18F-FDG distribution in cognitively normal older subjects

    PubMed Central

    Onishi, Airin; Fujiwara, Yoshinori; Ishiwata, Kiichi; Ishii, Kenji

    2017-01-01

    Background Increasing plasma glucose levels and insulin resistance can alter the distribution pattern of fluorine-18-labeled fluorodeoxyglucose (18F-FDG) in the brain and relatively reduce 18F-FDG uptake in Alzheimer's disease (AD)-related hypometabolic regions, leading to the appearance of an AD-like pattern. However, its relationship with plasma insulin levels is unclear. We aimed to compare the effects of plasma glucose levels, plasma insulin levels and insulin resistance on the appearance of the AD-like pattern in 18F-FDG images. Methods Fifty-nine cognitively normal older subjects (age = 75.7 ± 6.4 years) underwent 18F-FDG positron emission tomography along with measurement of plasma glucose and insulin levels. As an index of insulin resistance, the Homeostasis model assessment of Insulin Resistance (HOMA-IR) was calculated. Results Plasma glucose levels, plasma insulin levels, and HOMA-IR were 102.2 ± 8.1 mg/dL, 4.1 ± 1.9 μU/mL, and 1.0 ± 0.5, respectively. Whole-brain voxelwise analysis showed a negative correlation of 18F-FDG uptake with plasma glucose levels in the precuneus and lateral parietotemporal regions (cluster-corrected p < 0.05), and no correlation with plasma insulin levels or HOMA-IR. In the significant cluster, 18F-FDG uptake decreased by approximately 4–5% when plasma glucose levels increased by 20 mg/dL. In the precuneus region, volume-of-interest analysis confirmed a negative correlation of 18F-FDG uptake with plasma glucose levels (r = -0.376, p = 0.002), and no correlation with plasma insulin levels (r = 0.156, p = 0.12) or HOMA-IR (r = 0.096, p = 0.24). Conclusion This study suggests that, of the three parameters, plasma glucose levels have the greatest effect on the appearance of the AD-like pattern in 18F-FDG images. PMID:28715453

  4. One-Proton Breakup of 18F and the 17O(p,γ)18F Reaction in Classical Novae

    NASA Astrophysics Data System (ADS)

    Isherwood, Bryan; Banu, A.; E491 Collaboration

    2013-10-01

    Classical nova studies are of considerable interest for understanding the chemical evolution of the Galaxy. They have been proposed as the most significant source for the nucleosynthesis of the isotopes 13C, 15N, and 17O in the Universe. Novae are also likely to synthesize the short-lived radioisotope 18F (T1/2 = 110 min), which is expected to be the most important contributor to the observed emission of 511 keV gamma radiation by space-based γ-ray telescopes. This emission is produced by electron-positron annihilation following the beta + decay of radioactive nuclei. A detection of these gamma rays could significantly constrain the nova simulation models. 18F nucleosynthesis in classical novae strongly depends on the thermonuclear rate of the 17O(p,γ)18F reaction, which is part of the CNO cycle. This work presents preliminary results toward determination of the 17O(p,γ)18F reaction cross section, which was measured by the indirect method of one-proton nuclear breakup at intermediate energies. The experiment was carried out at GANIL using a beam of 18F at 40 MeV/u impinging on a carbon target. Longitudinal momentum distributions of the 17O breakup fragments were measured in coincidence with γ-rays emitted by 17O residues.

  5. Comparison of [(18)F]altanserin and [(18)F]deuteroaltanserin for PET imaging of serotonin(2A) receptors in baboon brain: pharmacological studies.

    PubMed

    Staley, J K; Van Dyck, C H; Tan, P Z; Al Tikriti, M; Ramsby, Q; Klump, H; Ng, C; Garg, P; Soufer, R; Baldwin, R M; Innis, R B

    2001-04-01

    The regional distribution in brain, distribution volumes, and pharmacological specificity of the PET 5-HT(2A) receptor radiotracer [(18)F]deuteroaltanserin were evaluated and compared to those of its non-deuterated derivative [(18)F]altanserin. Both radiotracers were administered to baboons by bolus plus constant infusion and PET images were acquired up to 8 h. The time-activity curves for both tracers stabilized between 4 and 6 h. The ratio of total and free parent to metabolites was not significantly different between radiotracers; nevertheless, total cortical R(T) (equilibrium ratio of specific to nondisplaceable brain uptake) was significantly higher (34-78%) for [(18)F]deuteroaltanserin than for [(18)F]altanserin. In contrast, the binding potential (Bmax/K(D)) was similar between radiotracers. [(18)F]Deuteroaltanserin cortical activity was displaced by the 5-HT(2A) receptor antagonist SR 46349B but was not altered by changes in endogenous 5-HT induced by fenfluramine. These findings suggest that [(18)F]deuteroaltanserin is essentially equivalent to [(18)F]altanserin for 5-HT(2A) receptor imaging in the baboon.

  6. Synthesis and evaluation of 18F-labeled CJ-042794 for imaging prostanoid EP4 receptor expression in cancer with positron emission tomography.

    PubMed

    Zhang, Zhengxing; Lau, Joseph; Kuo, Hsiou-Ting; Zhang, Chengcheng; Colpo, Nadine; Bénard, François; Lin, Kuo-Shyan

    2017-05-15

    The potent and selective prostanoid EP4 receptor antagonist CJ-042794 was radiolabeled with 18 F, and evaluated for imaging EP4 receptor expression in cancer with positron emission tomography (PET). The fluorination precursor, arylboronic acid pinacol ester 4, was prepared in 4 steps with 42% overall yield. 18 F-CJ-042794 was synthesized via a copper-mediated 18 F-fluorination reaction followed by base hydrolysis, and was obtained in 1.5±1.1% (n=2) decay-corrected radiochemical yield. PET/CT imaging and biodistribution studies in mice showed that 18 F-CJ-042794 was excreted through both renal and hepatobiliary pathways with significant retention in blood. The EP4-receptor-expressing LNCaP prostate cancer xenografts were clearly visualized in PET images with 1.12±0.08%ID/g (n=5) uptake value and moderate tumour-to-muscle contrast ratio (2.73±0.22) at 1h post-injection. However, the tumour uptake was nonspecific as it could not be blocked by co-injection of cold standard, precluding the application of 18 F-CJ-042794 for PET imaging of EP4 receptor expression in cancer. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Synthesis and Preclinical Evaluation of Three Novel Fluorine-18 Labeled Radiopharmaceuticals for P-Glycoprotein PET Imaging at the Blood-Brain Barrier.

    PubMed

    Savolainen, Heli; Cantore, Mariangela; Colabufo, Nicola A; Elsinga, Philip H; Windhorst, Albert D; Luurtsema, Gert

    2015-07-06

    P-Glycoprotein (P-gp), along with other transporter proteins at the blood-brain barrier (BBB), limits the entry of many pharmaceuticals into the brain. Altered P-gp function has been found in several neurological diseases. To study the P-gp function, many positron emission tomography (PET) radiopharmaceuticals have been developed. Most P-gp radiopharmaceuticals are labeled with carbon-11, while labeling with fluorine-18 would increase their applicability due to longer half-life. Here we present the synthesis and in vivo evaluation of three novel fluorine-18 labeled radiopharmaceuticals: 4-((6,7-dimethoxy-3,4-dihydroisoquinolin-2(1H)-yl)methyl)-2-(4-fluorophenyl)oxazole (1a), 2-biphenyl-4-yl-2-fluoroethoxy-6,7-dimethoxy-1,2,3,4-tetrahydro-isoquinoline (2), and 5-(1-(2-fluoroethoxy))-[3-(6,7-dimethoxy-3,4-dihydro-1H-isoquinolin-2-yl)-propyl]-5,6,7,8-tetrahydronaphthalen (3). Compounds were characterized as P-gp substrates in vitro, and Mdr1a/b((-/-))Bcrp1((-/-)) and wild-type mice were used to assess the substrate potential in vivo. Comparison was made to (R)-[(11)C]verapamil, which is currently the most frequently used P-gp substrate. Compound [(18)F]3 was performing the best out of the new radiopharmaceuticals; it had 2-fold higher brain uptake in the Mdr1a/b((-/-))Bcrp1((-/-)) mice compared to wild-type and was metabolically quite stable. In the plasma, 69% of the parent compound was intact after 45 min and 96% in the brain. Selectivity of [(18)F]3 to P-gp was tested by comparing the uptake in Mdr1a/b((-/-)) mice to uptake in Mdr1a/b((-/-))Bcrp1((-/-)) mice, which was statistically not significantly different. Hence, [(18)F]3 was found to be selective for P-gp and is a promising new radiopharmaceutical for P-gp PET imaging at the BBB.

  8. Preparation and characterization of a novel Al(18)F-NOTA-BZA conjugate for melanin-targeted imaging of malignant melanoma.

    PubMed

    Chang, Chih-Chao; Chang, Chih-Hsien; Lo, Yi-Hsuan; Lin, Ming-Hsien; Shen, Chih-Chieh; Liu, Ren-Shyan; Wang, Hsin-Ell; Chen, Chuan-Lin

    2016-08-15

    Melanin is an attractive target for the diagnosis and treatment of malignant melanoma. Previous studies have demonstrated the specific binding ability of benzamide moiety to melanin. In this study, we developed a novel (18)F-labeled NOTA-benzamide conjugate, Al(18)F-NOTA-BZA, which can be synthesized in 30min with a radiochemical yield of 20-35% and a radiochemical purity of >95%. Al(18)F-NOTA-BZA is highly hydrophilic (logP=-1.96) and shows good in vitro stability. Intravenous administration of Al(18)F-NOTA-BZA in two melanoma-bearing mouse models revealed highly specific uptake in B16F0 melanotic melanoma (6.67±0.91 and 1.50±0.26%ID/g at 15 and 120min p.i., respectively), but not in A375 amelanotic melanoma (0.87±0.21 and 0.24±0.09%ID/g at 15 and 120min p.i., respectively). The clearance from most normal tissues was fast. A microPET scan of Al(18)F-NOTA-BZA-injected mice also displayed high-contrast tumor images as compared with normal organs. Owing to the favorable in vivo distribution of Al(18)F-NOTA-BZA after intravenous administration, the estimated absorption dose was low in all normal organs and tissues. The melanin-specific binding ability, sustained tumor retention, fast normal tissues clearance and thelow projected human dosimetry supported that Al(18)F-NOTA-BZA is a very promising melanin-specific PET probe for melanin-positive melanoma. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Synthesis and animal studies of L-para-(/sup 18/F)-fluorophenyl-alanine as probe for in vivo cerebral protein synthesis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coenen, H.H.; Bodsch, W.; Takahashi, K.

    For the quantitation of cerebral protein synthesis in man by dynamic PET studies, fluorine-18 analogues seem superior to carbon-11 labeled substrates with respect to half-life and interference of amino acid metabolism giving rise to reutilization. Therefore, para- and ortho- /sup 18/F- fluorophenylalanine were prepared to study its metabolism in neuronal tissue. A labeling method was developed using direct electrophilic fluorination with (/sup 18/F)-F/sub 2/. Reaction of fluorine with L-phenylalanine in CF/sub 3/CO/sub 2/H at O/sup 0/C yielded 12-15% of ortho- and 6-8% of para-/sup 18/F-flurorophenylalanine. Isolation of the isomers was achieved by means of repeated RP-HPLC. The specific activity wasmore » about 2 Ci/mmole at 100 min after EOB. Both compounds showed a pharmacokinetic behaviour in mice after i.v. injection typical for natural amino acids. The accumulation in mice brain tissue reaches a plateau value after 5 min with 1.7% of the injected dose/g for para (2.5% in gerbils) and 2% for ortho. In a pilot study, about 1 mCi of p-/sup 18/F-phenylalanine was coinjected with 0.3 mCi (100 Ci/mmole) /sup 3/H-phenylalanine into the femoral vein of halothane-anesthetized Mongolian gerbils. The distribution obtained autoradiographyically in 20 ..mu..m sections of the frozen brain of an animal after 45 min revealed a similar pattern for both compounds indicating protein synthesis. In a parallel study 3-/sup 14/C-para-fluorophenylalanine was used to determine the chemical form of radioactivity in brain by means of HPLC. After 45 minutes, 7% of total brain activity was found as free amino acid and 60% was incorporated into proteins.« less

  10. Biodistribution and radiation dosimetry of LMI1195: first-in-human study of a novel 18F-labeled tracer for imaging myocardial innervation.

    PubMed

    Sinusas, Albert J; Lazewatsky, Joel; Brunetti, Jacqueline; Heller, Gary; Srivastava, Ajay; Liu, Yi-Hwa; Sparks, Richard; Puretskiy, Andrey; Lin, Shu-fei; Crane, Paul; Carson, Richard E; Lee, L Veronica

    2014-09-01

    A novel (18)F-labeled ligand for the norepinephrine transporter (N-[3-bromo-4-(3-(18)F-fluoro-propoxy)-benzyl]-guanidine [LMI1195]) is in clinical development for mapping cardiac nerve terminals in vivo using PET. Human safety, whole-organ biodistribution, and radiation dosimetry of LMI1195 were evaluated in a phase 1 clinical trial. Twelve healthy subjects at 3 clinical sites were injected intravenously with 150-250 MBq of LMI1195. Dynamic PET images were obtained over the heart for 10 min, followed by sequential whole-body images for approximately 5 h. Blood samples were obtained, and heart rate, electrocardiogram, and blood pressure were monitored before and during imaging. Residence times were determined from multiexponential regression of organ region-of-interest data normalized by administered activity (AA). Radiation dose estimates were calculated using OLINDA/EXM. Myocardial, lung, liver, and blood-pool standardized uptake values were determined at different time intervals. No adverse events due to LMI1195 were seen. Blood radioactivity cleared quickly, whereas myocardial uptake remained stable and uniform throughout the heart over 4 h. Liver and lung activity cleared relatively rapidly, providing favorable target-to-background ratios for cardiac imaging. The urinary bladder demonstrated the largest peak uptake (18.3% AA), followed by the liver (15.5% AA). The mean effective dose was 0.026 ± 0.0012 mSv/MBq. Approximately 1.6% AA was seen in the myocardium initially, remaining above 1.5% AA (decay-corrected) through 4 h after injection. The myocardium-to-liver ratio was approximately unity initially, increasing to more than 2 at 4 h. These preliminary data suggest that LMI1195 is well tolerated and yields a radiation dose comparable to that of other commonly used PET radiopharmaceuticals. The kinetics of myocardial and adjacent organ activity suggest that cardiac imaging should be possible with acceptable patient radiation dose. © 2014 by the Society of

  11. In vivo transport of three radioactive [18F]-fluorinated deoxysucrose analogs by the maize sucrose transporter ZmSUT1.

    PubMed

    Tran, Thu M; Hampton, Carissa S; Brossard, Tom W; Harmata, Michael; Robertson, J David; Jurisson, Silvia S; Braun, David M

    2017-06-01

    Sucrose transporter (SUT) proteins translocate sucrose across cell membranes; however, mechanistic aspects of sucrose binding by SUTs are not well resolved. Specific hydroxyl groups in sucrose participate in hydrogen bonding with SUT proteins. We previously reported that substituting a radioactive fluorine-18 [ 18 F] at the C-6' position within the fructosyl moiety of sucrose did not affect sucrose transport by the maize (Zea mays) ZmSUT1 protein. To determine how 18 F substitution of hydroxyl groups at two other positions within sucrose, the C-1' in the fructosyl moiety or the C-6 in the glucosyl moiety, impact sucrose transport, we synthesized 1'-[F 18 ]fluoro-1'-deoxysucrose and 6-[F 18 ]fluoro-6-deoxysucrose ([ 18 F]FDS) analogs. Each [ 18 F]FDS derivative was independently introduced into wild-type or sut1 mutant plants, which are defective in sucrose phloem loading. All three (1'-, 6'-, and 6-) [ 18 F]FDS derivatives were efficiently and equally translocated, similarly to carbon-14 [ 14 C]-labeled sucrose. Hence, individually replacing the hydroxyl groups at these positions within sucrose does not interfere with substrate recognition, binding, or membrane transport processes, and hydroxyl groups at these three positions are not essential for hydrogen bonding between sucrose and ZmSUT1. [ 18 F]FDS imaging afforded several advantages compared to [ 14 C]-sucrose detection. We calculated that 1'-[ 18 F]FDS was transported at approximately a rate of 0.90 ± 0.15 m.h-1 in wild-type leaves, and at 0.68 ± 0.25 m.h-1 in sut1 mutant leaves. Collectively, our data indicated that [ 18 F]FDS analogs are valuable tools to probe sucrose-SUT interactions and to monitor sucrose transport in plants. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  12. Copper-Mediated Radiofluorination of Arylstannanes with [18F]KF

    PubMed Central

    2016-01-01

    A copper-mediated nucleophilic radiofluorination of aryl- and vinylstannanes with [18F]KF is described. This method is fast, uses commercially available reagents, and is compatible with both electron-rich and electron-deficient arene substrates. This method has been applied to the manual synthesis of a variety of clinically relevant radiotracers including protected [18F]F-phenylalanine and [18F]F-DOPA. In addition, an automated synthesis of [18F]MPPF is demonstrated that delivers a clinically validated dose of 200 ± 20 mCi with a high specific activity of 2400 ± 900 Ci/mmol. PMID:27718581

  13. Copper-Mediated Radiofluorination of Arylstannanes with [ 18F]KF

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Makaravage, Katarina J.; Brooks, Allen F.; Mossine, Andrew V.

    In this article, a copper-mediated nucleophilic radiofluorination of aryl- and vinylstannanes with [ 18F]KF is described. This method is fast, uses commercially available reagents, and is compatible with both electron-rich and electron-deficient arene substrates. This method has been applied to the manual synthesis of a variety of clinically relevant radiotracers including protected [ 18F]F-phenylalanine and [ 18F]F-DOPA. In addition, an automated synthesis of [ 18F]MPPF is demonstrated that delivers a clinically validated dose of 200 ± 20 mCi with a high specific activity of 2400 ± 900 Ci/mmol.

  14. Copper-Mediated Radiofluorination of Arylstannanes with [ 18F]KF

    DOE PAGES

    Makaravage, Katarina J.; Brooks, Allen F.; Mossine, Andrew V.; ...

    2016-10-10

    In this article, a copper-mediated nucleophilic radiofluorination of aryl- and vinylstannanes with [ 18F]KF is described. This method is fast, uses commercially available reagents, and is compatible with both electron-rich and electron-deficient arene substrates. This method has been applied to the manual synthesis of a variety of clinically relevant radiotracers including protected [ 18F]F-phenylalanine and [ 18F]F-DOPA. In addition, an automated synthesis of [ 18F]MPPF is demonstrated that delivers a clinically validated dose of 200 ± 20 mCi with a high specific activity of 2400 ± 900 Ci/mmol.

  15. Distribution of adoptively transferred porcine T-lymphoblasts tracked by (18)F-2-fluoro-2-deoxy-D-glucose and position emission tomography.

    PubMed

    Eriksson, Olof; Sadeghi, Arian; Carlsson, Björn; Eich, Torsten; Lundgren, Torbjörn; Nilsson, Bo; Tötterman, Thomas; Korsgren, Olle; Sundin, Anders

    2011-08-01

    Autologous or allogeneic transfer of tumor-infiltrating T-lymphocytes is a promising treatment for metastatic cancers, but a major concern is the difficulty in evaluating cell trafficking and distribution in adoptive cell therapy. This study presents a method of tracking transfusion of T-lymphoblasts in a porcine model by (18)F-2-fluoro-2-deoxy-d-glucose ([(18)F]FDG) and positron emission tomography. T-lymphoblasts were labeled with the positron-emitting tracer [(18)F]FDG through incubation. The T-lymphoblasts were administered into the bloodstream, and the distribution was followed by positron emission tomography for 120 min. The cells were administered either intravenously into the internal jugular vein (n=5) or intraarterially into the ascending aorta (n=1). Two of the pigs given intravenous administration were pretreated with low-molecular-weight dextran sulphate. The cellular kinetics and distribution were readily quantifiable for up to 120 min. High (78.6% of the administered cells) heterogeneous pulmonary uptake was found after completed intravenous transfusion. The pulmonary uptake was decreased either by preincubating and coadministrating the T-lymphoblasts with low-molecular-weight dextran sulphate or by administrating them intraarterially. The present work shows the feasibility of quantitatively monitoring and evaluating cell trafficking and distribution following administration of [(18)F]FDG-labeled T-lymphoblasts. The protocol can potentially be transferred to the clinical setting with few modifications. Copyright © 2011 Elsevier Inc. All rights reserved.

  16. Highly efficient one-pot labeling of new phosphonium cations with fluorine-18 as potential PET agents for myocardial perfusion imaging.

    PubMed

    Zhao, Zuoquan; Yu, Qian; Mou, Tiantian; Liu, Chang; Yang, Wenjiang; Fang, Wei; Peng, Cheng; Lu, Jie; Liu, Yu; Zhang, Xianzhong

    2014-11-03

    Lipophilic cations such as phosphonium salts can accumulate in mitochondria of heart in response to the negative inner-transmembrane potentials. Two phosphonium salts [(18)F]FMBTP and [(18)F]mFMBTP were prepared and evaluated as potential myocardial perfusion imaging (MPI) agents in this study. The cations were radiolabeled via a simplified one-pot method starting from [(18)F]fluoride and followed by physicochemical property tests, in vitro cellular uptake assay, ex vivo mouse biodistribution, and in vivo rat microPET imaging. The total radiosynthesis time was less than 60 min including HPLC purification. The [(18)F] labeled compounds were obtained in high radiolabeling yield (∼50%) and good radiochemical purity (>99%). Both compounds were electropositive, and their log P values at pH 7.4 were 1.16 ± 0.003 (n = 3) and 1.05 ± 0.01 (n = 3), respectively. Both [(18)F]FMBTP and [(18)F]mFMBTP had high heart uptake (25.24 ± 2.97% ID/g and 31.02 ± 0.33% ID/g at 5 min postinjection (p.i.)) in mice with good retention (28.99 ± 3.54% ID/g and 26.82 ± 3.46% ID/g at 120 min p.i.). From the PET images in rats, the cations exhibited high myocardium uptake and fast clearance from liver and small intestine to give high-contrast images across all time points. These phosphonium cations were radiosynthesized via a highly efficient one-pot procedure for potential MPI offering high heart accumulation and rapid nontarget clearance.

  17. Comparison of Positron Emission Tomography Using 2-[18F]-fluoro-2-deoxy-D-glucose and 3-deoxy-3-[18F]-fluorothymidine in Lung Cancer Imaging

    PubMed Central

    Wang, Fu-Li; Tan, Ye-Ying; Gu, Xiang-Min; Li, Tian-Ran; Lu, Guang-Ming; Liu, Gang; Huo, Tian-Long

    2016-01-01

    Background: The detection of solitary pulmonary nodules (SPNs) that may potentially develop into a malignant lesion is essential for early clinical interventions. However, grading classification based on computed tomography (CT) imaging results remains a significant challenge. The 2-[18F]-fluoro-2-deoxy-D-glucose (18F-FDG) positron emission tomography (PET)/CT imaging produces both false-positive and false-negative findings for the diagnosis of SPNs. In this study, we compared 18F-FDG and 3-deoxy-3-[18F]-fluorothymidine (18F-FLT) in lung cancer PET/CT imaging. Methods: The binding ratios of the two tracers to A549 lung cancer cells were calculated. The mouse lung cancer model was established (n = 12), and micro-PET/CT analysis using the two tracers was performed. Images using the two tracers were collected from 55 lung cancer patients with SPNs. The correlation among the cell-tracer binding ratios, standardized uptake values (SUVs), and Ki-67 proliferation marker expression were investigated. Results: The cell-tracer binding ratio for the A549 cells using the 18F-FDG was greater than the ratio using 18F-FLT (P < 0.05). The Ki-67 expression showed a significant positive correlation with the 18F-FLT binding ratio (r = 0.824, P < 0.01). The tumor-to-nontumor uptake ratio of 18F-FDG imaging in xenografts was higher than that of 18F-FLT imaging. The diagnostic sensitivity, specificity, and the accuracy of 18F-FDG for lung cancer were 89%, 67%, and 73%, respectively. Moreover, the diagnostic sensitivity, specificity, and the accuracy of 18F-FLT for lung cancer were 71%, 79%, and 76%, respectively. There was an obvious positive correlation between the lung cancer Ki-67 expression and the mean maximum SUV of 18F-FDG and 18F-FLT (r = 0.658, P < 0.05 and r = 0.724, P < 0.01, respectively). Conclusions: The 18F-FDG uptake ratio is higher than that of 18F-FLT in A549 cells at the cellular level. 18F-FLT imaging might be superior for the quantitative diagnosis of lung tumor

  18. Comparison of the Cardiac MicroPET Images Obtained Using [(18)F]FPTP and [(13)N]NH3 in Rat Myocardial Infarction Models.

    PubMed

    Kim, Dong-Yeon; Kim, Hyeon Sik; Jang, Hwa Youn; Kim, Ju Han; Bom, Hee-Seung; Min, Jung-Joon

    2014-10-09

    The short half-life of current positron emission tomography (PET) cardiac tracers limits their widespread clinical use. We previously developed a (18)F-labeled phosphonium cation, [(18)F]FPTP, that demonstrated sharply defined myocardial defects in a corresponding infarcted myocardium. The aim of this study was to compare the image properties of PET scans obtained using [(18)F]FPTP with those obtained using [(13)N]NH3 in rat myocardial infarction models. Perfusion abnormality was analyzed in 17 segments of polar map images. The myocardium-to-liver and myocardium-to-lung ratios of [(18)F]FPTP were 10.48 and 2.65 times higher, respectively, than those of [(13)N]NH3 in images acquired 30 min after tracer injection. The myocardial defect size measured by [(18)F]FPTP correlated more closely with the hypoperfused area measured by quantitative 2,3,5-triphenyltetrazolium chloride staining (r = 0.89, P < 0.01) than did [(13)N]NH3 (r = 0.84, P < 0.01). [(18)F]FPTP might be useful as a replacement for the myocardial agent [(13)N]NH3 in cardiac PET/CT applications.

  19. 18F-FDG uptake in the colon is modulated by metformin but not associated with core body temperature and energy expenditure.

    PubMed

    Bahler, Lonneke; Holleman, Frits; Chan, Man-Wai; Booij, Jan; Hoekstra, Joost B; Verberne, Hein J

    2017-01-01

    Physiological colonic 18F-fluorodeoxyglucose (18F-FDG) uptake is a frequent finding on 18F-FDG positron emission tomography computed tomography (PET-CT). Interestingly, metformin, a glucose lowering drug associated with moderate weight loss, is also associated with an increased colonic 18F-FDG uptake. Consequently, increased colonic glucose use might partly explain the weight losing effect of metformin when this results in an increased energy expenditure and/or core body temperature. Therefore, we aimed to determine whether metformin modifies the metabolic activity of the colon by increasing glucose uptake. In this open label, non-randomized, prospective mechanistic study, we included eight lean and eight overweight males. We measured colonic 18F-FDG uptake on PET-CT, energy expenditure and core body temperature before and after the use of metformin. The maximal colonic 18F-FDG uptake was measured in 5 separate segments (caecum, colon ascendens,-transversum,-descendens and sigmoid). The maximal colonic 18F-FDG uptake increased significantly in all separate segments after the use of metformin. There was no significant difference in energy expenditure or core body temperature after the use of metformin. There was no correlation between maximal colonic 18F-FDG uptake and energy expenditure or core body temperature. Metformin significantly increases colonic 18F-FDG uptake, but this increased uptake is not associated with an increase in energy expenditure or core body temperature. Although the colon might be an important site of the glucose plasma lowering actions of metformin, this mechanism of action does not explain directly any associated weight loss.

  20. Development of PEGylated peptide probes conjugated with (18)F-labeled BODIPY for PET/optical imaging of MT1-MMP activity.

    PubMed

    Kondo, Naoya; Temma, Takashi; Deguchi, Jun; Sano, Kohei; Ono, Masahiro; Saji, Hideo

    2015-12-28

    Since the processing activity of the matrix metalloproteinase MT1-MMP regulates various cellular functions such as motility, invasion, growth, differentiation and apoptosis, precise in vivo evaluation of MT1-MMP activity in cancers can provide beneficial information for both basic and clinical studies. For this purpose, we designed a cleavable Positron Emission Tomography (PET)/optical imaging probe consisting of BODIPY650/665 and polyethylene glycol (PEG) conjugated to opposite ends of MT1-MMP substrate peptides. We used in vitro and in vivo fluorescence experiments to select suitable substrate peptide sequences and PEG sizes for the MT1-MMP probes and obtained an optimized structure referred to here as MBP-2k. Radiofluorinated MBP-2k ([(18)F]MBP-2k) was then successfully synthesized via an (18)F-(19)F isotopic exchange reaction in BODIPY650/665. After intravenous injection into mice with xenografted tumors, [(18)F]MBP-2k showed significantly higher accumulation in HT1080 tumors with high MT1-MMP activity than in A549 tumors that have low MT1-MMP activity. Moreover, PET images showed better contrast in HT1080 tumors. These results show that [(18)F]MBP-2k can be used as a hybrid PET/optical imaging agent and is a promising probe for non-invasive monitoring of MT1-MMP activity in cancers. This probe may also efficiently combine targeted tumor imaging with image-guided surgery that could be beneficial for patients in the future. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Radiation absorbed dose estimates for 18F-BPA PET.

    PubMed

    Kono, Yuzuru; Kurihara, Hiroaki; Kawamoto, Hiroshi; Yasui, Naoko; Honda, Naoki; Igaki, Hiroshi; Itami, Jun

    2017-09-01

    Background Boron neutron capture therapy (BNCT) is a molecular radiation therapy approach based on the 10 B (n, α) 7 Li nuclear reaction in cancer cells. In BNCT, delivery of 10 B in the form of 4-borono-phenylalanine conjugated with fructose (BPA-fr) to the cancer cells is important. The PET tracer 4-borono-2-18F-fluoro-phenylalanine (FBPA) has been used to predict the accumulation of BPA-fr before BNCT. Purpose To determine the biodistribution and dosimetric parameters in 18F-BPA PET/CT studies. Material and Methods Human biokinetic data were obtained during clinical 18F-BPA PET studies between February and June 2015 at one institution. Nine consecutive patients were studied prospectively. The internal radiation dose was calculated on the basis of radioactivity data from blood, urine, and normal tissue of the heart, liver, spleen, kidney, and other parts of the body at each time point using OLINDA/EXM1.1 program. We compared our calculations with published 18F-FDG data. Results Adult patients (3 men, 3 women; age range, 28-68 years) had significantly smaller absorbed doses than pediatric patients (3 patients; age range, 5-12 years) ( P = 0.003). The mean effective dose was 57% lower in adult patients compared with pediatric patients. Mean effective doses for 18F-BPA were 25% lower than those for 18F-FDG presented in International Commission of Radiation Protection (ICRP) publication 106. Conclusion We found significant differences in organ absorbed doses for 18F-BPA against those for 18F-FDG presented in ICRP publication 106. Mean effective doses for 18F-BPA were smaller than those for 18F-FDG in the publication by 0.5-38% (mean difference, 25%).

  2. 17 CFR 270.18f-1 - Exemption from certain requirements of section 18(f)(1) (of the Act) for registered open-end...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... requirements of section 18(f)(1) (of the Act) for registered open-end investment companies which have the right... EXCHANGE COMMISSION (CONTINUED) RULES AND REGULATIONS, INVESTMENT COMPANY ACT OF 1940 § 270.18f-1 Exemption from certain requirements of section 18(f)(1) (of the Act) for registered open-end investment companies...

  3. Can the inflammatory response be evaluated using 18F-FDG within zones of microvascular obstruction after myocardial infarction?

    PubMed

    Prato, Frank S; Butler, John; Sykes, Jane; Keenliside, Lynn; Blackwood, Kimberley J; Thompson, R Terry; White, James A; Mikami, Yoko; Thiessen, Jonathan D; Wisenberg, Gerald

    2015-02-01

    Inflammation that occurs after acute myocardial infarction plays a pivotal role in healing by facilitating the creation of a supportive scar. (18)F-FDG, which is taken up avidly by macrophages, has been proposed as a marker of cell-based inflammation. However, its reliability as an accurate indicator of inflammation has not been established, particularly in the early postinfarction period when regional myocardial perfusion is often severely compromised. Nine adult dogs underwent left anterior descending coronary occlusion with or without reperfusion. Animals were imaged between 7 and 21 d after infarction with PET/MR imaging after bolus injection of gadolinium-diethylenetriaminepentaacetic acid (DTPA), bolus injection of (18)F-FDG, bolus injection of (99)Tc-DTPA to simulate the distribution of gadolinium-DTPA (which represents its partition coefficient in well-perfused tissue), and injection of (111)In-labeled white blood cells 24 h earlier. After sacrifice, myocardial tissue concentrations of (18)F, (111)In, and (99)Tc were determined in a well counter. Linear regression analysis evaluated the relationships between the concentrations of (111)In and (18)F and the dependence of the ratio of (111)In/(18)F to the apparent distribution volume of (99m)Tc-DTPA. In 7 of 9 animals, (111)In increased as (18)F increased with the other 2 animals, showing weak negative slopes. With respect to the dependence of (111)In/(18)F with partition coefficient, 4 animals showed no dependence and 4 showed a weak positive slope, with 1 animal showing a negative slope. Further, in regions of extensive microvascular obstruction, (18)F significantly underestimated the extent of the presence of (111)In. In the early post-myocardial infarction period, (18)F-FDG PET imaging after a single bolus administration may underestimate the extent and degree of inflammation within regions of microvascular obstruction. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  4. Incorporation and translocation of 2-deoxy-2-[(18)F]fluoro-D-glucose in Sorghum bicolor (L.) Moench monitored using a planar positron imaging system.

    PubMed

    Hattori, Etsuko; Uchida, Hiroshi; Harada, Norihiro; Ohta, Mari; Tsukada, Hideo; Hara, Yasuhiro; Suzuki, Tetsuya

    2008-04-01

    [(18)F]FDG (2-deoxy-2-[(18)F]fluoro-D-glucose) was fed to a sorghum plant [Sorghum bicolor (L.) Moench] from the tip of a leaf and its movement was monitored using a planar positron imaging system (PPIS). [(18)F]FDG was uptaken from the leaf tip and it was translocated to the basal part of the shoots from where it moved to the roots, the tillers and the sheaths. Autoradiographic analysis of the distribution of (18)F, [(18)F]FDG and/or its metabolites showed translocation to the roots, tillers, and to the leaves that were younger than the supplied leaf. Strong labelling was observed in the basal part of the shoots, in the sheaths, the youngest leaf and the root tips. Our results indicate that [(18)F]FDG and/or its metabolites were absorbed from the leaf and translocated to the sites where nutrients are required. This strongly suggests that [(18)F]FDG can be utilised as a tracer to study photoassimilate translocation in the living plant. This is the first report on the use of [(18)F]FDG, which is routinely used as a probe for clinical diagnosis, to study source to sink translocation of metabolites in whole plants in real time.

  5. Reliable radiosynthesis of 4-[10B]borono-2-[18F]fluoro-L-phenylalanine with quality assurance for boron neutron capture therapy-oriented diagnosis.

    PubMed

    Ishiwata, Kiichi; Ebinuma, Ryoichi; Watanabe, Chuichi; Hayashi, Kunpei; Toyohara, Jun

    2018-06-05

    The aim of this study was to establish a reliable and routine method for the preparation of 4-[ 10 B]borono-2-[ 18 F]fluoro-L-phenylalanine (L-[ 18 F]FBPA) for boron neutron capture therapy-oriented diagnosis using positron emission tomography. To produce L-[ 18 F]FBPA by electrophilic fluorination of 4-[ 10 B]borono-L-phenylalanine (L-BPA) with [ 18 F]acetylhypofluorite ([ 18 F]AcOF) via [ 18 F]F 2 derived from the 20 Ne(d,α) 18 F nuclear reaction, several preparation parameters and characteristics of L-[ 18 F]FBPA were investigated, including: pre-irradiation for [ 18 F]F 2 production, the carrier F 2 content in the Ne target, L-BPA-to-F 2 ratios, separation with high-performance liquid chromatography (HPLC) using 10 different eluents, enantiomeric purity, and residual trifluoroacetic acid used as the reaction solvent by gas chromatography-mass spectrometry. The activity yields and molar activities of L-[ 18 F]FBPA (n = 38) were 1200 ± 160 MBq and 46-113 GBq/mmol, respectively, after deuteron-irradiation for 2 h. Two 5 min pre-irradiations prior to [ 18 F]F 2 production for 18 F-labeling were preferable. For L-[ 18 F]FBPA synthesis, 0.15-0.2% of carrier F 2 in Ne and L-BPA-to-F 2 ratios > 2 were preferable. HPLC separations with five of the 10 eluents provided injectable L-[ 18 F]FBPA without any further formulation processing, which resulted in a synthesis time of 32 min. Among the five eluents, 1 mM phosphate-buffered saline was the eluent of choice. The L-[ 18 F]FBPA injection was sterile and pyrogen-free, and contained very small amounts of D-enantiomer (< 0.1% of L-[ 18 F]FBPA), L-BPA (< 1% of L-FBPA), and trifluoroacetic acid (< 0.5 ppm). L-[ 18 F]FBPA injection was reliably prepared by the electrophilic fluorination of L-BPA with [ 18 F]AcOF followed by HPLC separation with 1 mM phosphate-buffered saline.

  6. In vivo assessment and dosimetry of 2 novel PDE10A PET radiotracers in humans: 18F-MNI-659 and 18F-MNI-654.

    PubMed

    Barret, Olivier; Thomae, David; Tavares, Adriana; Alagille, David; Papin, Caroline; Waterhouse, Rikki; McCarthy, Timothy; Jennings, Danna; Marek, Ken; Russell, David; Seibyl, John; Tamagnan, Gilles

    2014-08-01

    Phosphodiesterase (PDE) 10A is an enzyme involved in the regulation of cyclic adenosine monophosphate and cyclic guanosine monophosphate and is highly expressed in medium-sized spiny neurons of the striatum, making it an attractive target for novel therapies for a variety of neurologic and psychiatric disorders that involve striatal function. Potential ligands for PET imaging of PDE10A have been reported. Here, we report the first-in-human characterization of 2 new PDE10A radioligands, 2-(2-(3-(1-(2-fluoroethyl)-1H-indazol-6-yl)-7-methyl-4-oxo-3,4-dihydroquinazolin-2-yl)ethyl)-4-isopropoxyisoindoline-1,3-dione ((18)F-MNI-654) and 2-(2-(3-(4-(2-fluoroethoxy)phenyl)-7-methyl-4-oxo-3,4-dihydroquinazolin-2-yl)ethyl)-4-isopropoxyisoindoline-1,3-dione ((18)F-MNI-659), with the goal of selecting the best one for use in future studies interrogating pathophysiologic changes in neuropsychiatric disorders and aiding pharmaceutical development targeting PDE10A. Eleven healthy volunteers participated in this study ((18)F-MNI-654 test-retest, 2 men; (18)F-MNI-659 test-retest, 4 men and 1 woman; (18)F-MNI-659 dosimetry, 2 men and 2 women). Brain PET images were acquired over 5.5 h for (18)F-MNI-654 and over 3.5 h for (18)F-MNI-659, and pharmacokinetic modeling with plasma- and reference-region (cerebellar cortex)-based methods was performed. Whole-body PET images were acquired over 6 h for (18)F-MNI-659 and radiation dosimetry estimated with OLINDA. Both radiotracers were similarly metabolized, with about 20% of intact parent remaining at 120 min after injection. PET time-activity data demonstrated that (18)F-MNI-654 kinetics were much slower than (18)F-MNI-659 kinetics. For (18)F-MNI-659, there was good agreement between the Logan and simplified reference tissue models for nondisplaceable binding potential (BPND), supporting noninvasive quantification, with test-retest variability less than 10% and intraclass correlation greater than 0.9. The (18)F-MNI-659 effective dose was

  7. Bacterial infection imaging with [18F]fluoropropyl-trimethoprim

    PubMed Central

    Lee, Iljung; Hou, Catherine; Weng, Chi-Chang; Li, Shihong; Lieberman, Brian P.; Zeng, Chenbo; Mankoff, David A.; Mach, Robert H.

    2017-01-01

    There is often overlap in the diagnostic features of common pathologic processes such as infection, sterile inflammation, and cancer both clinically and using conventional imaging techniques. Here, we report the development of a positron emission tomography probe for live bacterial infection based on the small-molecule antibiotic trimethoprim (TMP). [18F]fluoropropyl-trimethoprim, or [18F]FPTMP, shows a greater than 100-fold increased uptake in vitro in live bacteria (Staphylococcus aureus, Escherichia coli, and Pseudomonas aeruginosa) relative to controls. In a rodent myositis model, [18F]FPTMP identified live bacterial infection without demonstrating confounding increased signal in the same animal from other etiologies including chemical inflammation (turpentine) and cancer (breast carcinoma). Additionally, the biodistribution of [18F]FPTMP in a nonhuman primate shows low background in many important tissues that may be sites of infection such as the lungs and soft tissues. These results suggest that [18F]FPTMP could be a broadly useful agent for the sensitive and specific imaging of bacterial infection with strong translational potential. PMID:28716936

  8. 18F-FDG uptake in the colon is modulated by metformin but not associated with core body temperature and energy expenditure

    PubMed Central

    Bahler, Lonneke; Holleman, Frits; Chan, Man-Wai; Booij, Jan; Hoekstra, Joost B.; Verberne, Hein J.

    2017-01-01

    Purpose Physiological colonic 18F-fluorodeoxyglucose (18F-FDG) uptake is a frequent finding on 18F-FDG positron emission tomography computed tomography (PET-CT). Interestingly, metformin, a glucose lowering drug associated with moderate weight loss, is also associated with an increased colonic 18F-FDG uptake. Consequently, increased colonic glucose use might partly explain the weight losing effect of metformin when this results in an increased energy expenditure and/or core body temperature. Therefore, we aimed to determine whether metformin modifies the metabolic activity of the colon by increasing glucose uptake. Methods In this open label, non-randomized, prospective mechanistic study, we included eight lean and eight overweight males. We measured colonic 18F-FDG uptake on PET-CT, energy expenditure and core body temperature before and after the use of metformin. The maximal colonic 18F-FDG uptake was measured in 5 separate segments (caecum, colon ascendens,—transversum,—descendens and sigmoid). Results The maximal colonic 18F-FDG uptake increased significantly in all separate segments after the use of metformin. There was no significant difference in energy expenditure or core body temperature after the use of metformin. There was no correlation between maximal colonic 18F-FDG uptake and energy expenditure or core body temperature. Conclusion Metformin significantly increases colonic 18F-FDG uptake, but this increased uptake is not associated with an increase in energy expenditure or core body temperature. Although the colon might be an important site of the glucose plasma lowering actions of metformin, this mechanism of action does not explain directly any associated weight loss. PMID:28464031

  9. A high-affinity [ 18F]-labeled phosphoramidate peptidomimetic PSMA-targeted inhibitor for PET imaging of prostate cancer

    DOE PAGES

    Ganguly, Tanushree; Dannoon, Shorouk; Hopkins, Mark R.; ...

    2015-06-09

    Here in this study, a structurally modified phosphoramidate scaffold, with improved prostate-specific membrane antigen (PSMA) avidity, stability and in vivo characteristics, as a PET imaging agent for prostate cancer (PCa), was prepared and evaluated. p-Fluorobenzoyl-aminohexanoate and 2-(3-hydroxypropyl)glycine were introduced into the PSMA-targeting scaffold yielding phosphoramidate 5. X-ray crystallography was performed on the PSMA/5 complex. [ 18F]5 was synthesized, and cell uptake and internalization studies were conducted in PSMA(+) LNCaP and CWR22Rv1 cells and PSMA(-) PC-3 cells. In vivo PET imaging and biodistribution studies were performed at 1 and 4 h post injection in mice bearing CWR22Rv1 tumor, with or withoutmore » blocking agent. The crystallographic data showed interaction of the p-fluorobenzoyl group with an arene-binding cleft on the PSMA surface. In vitro studies revealed elevated uptake of [ 18F]5 in PSMA(+) cells (2.2% in CWR22Rv1 and 12.1% in LNCaP) compared to PSMA(-) cells (0.08%) at 4 h. In vivo tumor uptake of 2.33% ID/g and tumor-to-blood ratio of 265:1 was observed at 4 h. In conclusion, we have successfully synthesized, radiolabeled and evaluated a new PSMA-targeted PET agent. The crystal structure of the PSMA/5 complex highlighted the interactions within the arene-binding cleft contributing to the overall complex stability. The high target uptake and rapid non-target clearance exhibited by [ 18F]5 in PSMA(+) xenografts substantiates its potential use for PET imaging of PCa.« less

  10. Recent Developments of 18F-FET PET in Neuro-oncology.

    PubMed

    Muoio, Barbara; Giovanella, Luca; Treglia, Giorgio

    2017-11-23

    From the past decade to date several studies about O-(2-[18F]fluoroethyl)-L-tyrosine (18F-FET) positron emission tomography (PET) in brain tumours have been published in the literature. Objective The aim of this narrative review is to summarize the recent developments and the current role of 18F-FET PET in brain tumours according to recent literature data. Methods Main findings from selected recently published and relevant articles on the role of 18F-FET PET in neuro-oncology were described. Results 18F-FET PET may be useful in the differential diagnosis between brain tumours and non-neoplastic lesions and between low-grade and high-grade gliomas. Integration of 18F-FET PET into surgical planning allows better delineation of the extent of resection beyond margins visible with standard MRI. For biopsy planning, 18F-FET PET is particularly useful in identifying malignant foci within non-contrast-enhancing gliomas. 18F-FET PET may improve the radiation therapy planning in patients with gliomas. This metabolic imaging method may be useful to evaluate treatment response in patients with gliomas and it improves the differential diagnosis between brain tumours recurrence and post-treatment changes. 18F-FET PET may provide useful prognostic information in high-grade gliomas. Conclusions Based on recent literature data 18F-FET PET may provide additional diagnostic information compared to standard MRI in neuro-oncology. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  11. Combined use of (18)F-FDG and (18)F-FMISO in unresectable non-small cell lung cancer patients planned for radiotherapy: a dynamic PET/CT study.

    PubMed

    Sachpekidis, Christos; Thieke, Christian; Askoxylakis, Vasileios; Nicolay, Nils H; Huber, Peter E; Thomas, Michael; Dimitrakopoulou, Georgia; Debus, Juergen; Haberkorn, Uwe; Dimitrakopoulou-Strauss, Antonia

    2015-01-01

    Aim of this study was to evaluate and compare, by means of dynamic and static PET/CT, the distribution patterns and pharmacokinetics of fluorine-18 fluorodeoxyglucose ((18)F-FDG) and of fluorine-18-fluoromisonidazole ((18)F-FMISO) in non-small cell lung cancer (NSCLC) patients scheduled for intensity modulated radiation therapy (IMRT). Thirteen patients suffering from inoperable stage III NSCLC underwent PET/CTs with (18)F-FDG and (18)F-FMISO for tumor metabolism and hypoxia assessment accordingly. Evaluation of PET/CT studies was based on visual analysis, semi-quantitative (SUV) calculations and absolute quantitative estimations, after application of a two-tissue compartment model and a non-compartmental approach. (18)F-FDG PET/CT revealed all thirteen primary lung tumors as sites of increased (18)F-FDG uptake. Six patients demonstrated also in total 43 (18)F-FDG avid metastases; these patients were excluded from radiotherapy. (18)F-MISO PET/CT demonstrated 12/13 primary lung tumors with faint tracer uptake. Only one tumor was clearly (18)F-FMISO avid, (SUVaverage = 3.4, SUVmax = 5.0). Mean values for (18)F-FDG, as derived from dPET/CT data, were SUVaverage = 8.9, SUVmax = 15.1, K1 = 0.23, k2 = 0.53, k3 = 0.17, k4 = 0.02, influx = 0.05 and fractal dimension (FD) = 1.25 for the primary tumors. The respective values for (18)F-FMISO were SUVaverage = 1.4, SUVmax = 2.2, K1 = 0.26, k2 = 0.56, k3 = 0.06, k4 = 0.06, influx = 0.02 and FD = 1.14. No statistically significant correlation was observed between the two tracers. (18)F-FDG PET/CT changed therapy management in six patients, by excluding them from planned IMRT. (18)F-FMISO PET/CT revealed absence of significant tracer uptake in the majority of the (18)F-FDG avid NSCLCs. Lack of correlation between the two tracers' kinetics indicates that they reflect different molecular mechanisms and implies the discordance between increased glycolysis and hypoxia in the malignancy.

  12. Combined use of 18F-FDG and 18F-FMISO in unresectable non-small cell lung cancer patients planned for radiotherapy: a dynamic PET/CT study

    PubMed Central

    Sachpekidis, Christos; Thieke, Christian; Askoxylakis, Vasileios; Nicolay, Nils H; Huber, Peter E; Thomas, Michael; Dimitrakopoulou, Georgia; Debus, Juergen; Haberkorn, Uwe; Dimitrakopoulou-Strauss, Antonia

    2015-01-01

    Aim of this study was to evaluate and compare, by means of dynamic and static PET/CT, the distribution patterns and pharmacokinetics of fluorine-18 fluorodeoxyglucose (18F-FDG) and of fluorine-18-fluoromisonidazole (18F-FMISO) in non-small cell lung cancer (NSCLC) patients scheduled for intensity modulated radiation therapy (IMRT). Thirteen patients suffering from inoperable stage III NSCLC underwent PET/CTs with 18F-FDG and 18F-FMISO for tumor metabolism and hypoxia assessment accordingly. Evaluation of PET/CT studies was based on visual analysis, semi-quantitative (SUV) calculations and absolute quantitative estimations, after application of a two-tissue compartment model and a non-compartmental approach. 18F-FDG PET/CT revealed all thirteen primary lung tumors as sites of increased 18F-FDG uptake. Six patients demonstrated also in total 43 18F-FDG avid metastases; these patients were excluded from radiotherapy. 18F-MISO PET/CT demonstrated 12/13 primary lung tumors with faint tracer uptake. Only one tumor was clearly 18F-FMISO avid, (SUVaverage = 3.4, SUVmax = 5.0). Mean values for 18F-FDG, as derived from dPET/CT data, were SUVaverage = 8.9, SUVmax = 15.1, K1 = 0.23, k2 = 0.53, k3 = 0.17, k4 = 0.02, influx = 0.05 and fractal dimension (FD) = 1.25 for the primary tumors. The respective values for 18F-FMISO were SUVaverage = 1.4, SUVmax = 2.2, K1 = 0.26, k2 = 0.56, k3 = 0.06, k4 = 0.06, influx = 0.02 and FD = 1.14. No statistically significant correlation was observed between the two tracers. 18F-FDG PET/CT changed therapy management in six patients, by excluding them from planned IMRT. 18F-FMISO PET/CT revealed absence of significant tracer uptake in the majority of the 18F-FDG avid NSCLCs. Lack of correlation between the two tracers’ kinetics indicates that they reflect different molecular mechanisms and implies the discordance between increased glycolysis and hypoxia in the malignancy. PMID:25973334

  13. Sulfonation of Tyrosine as a Method To Improve Biodistribution of Peptide-Based Radiotracers: Novel 18F-Labeled Cyclic RGD Analogues.

    PubMed

    Haskali, Mohammad B; Denoyer, Delphine; Noonan, Wayne; Culinane, Carleen; Rangger, Christine; Pouliot, Normand; Haubner, Roland; Roselt, Peter D; Hicks, Rodney J; Hutton, Craig A

    2017-04-03

    Control of the biodistribution of radiolabeled peptides has proven to be a major challenge in their application as imaging agents for positron emission tomography (PET). Modification of peptide hydrophilicity in order to increase renal clearance has been a common endeavor to improve overall biodistribution. Herein, we examine the effect of site-specific sulfonation of tyrosine moieties in cyclic(RGDyK) peptides as a means to enhance their hydrophilicity and improve their biodistribution. The novel sulfonated cyclic(RGDyK) peptides were conjugated directly to 4-nitrophenyl 2-[ 18 F]fluoropropionate, and the biodistribution of the radiolabeled peptides was compared with that of their nonsulfonated, clinically relevant counterparts, [ 18 F]GalactoRGD and [ 18 F]FPPRGD2. Site-specific sulfonation of the tyrosine residues was shown to increase hydrophilicity and improve biodistribution of the RGD peptides, despite contributing just 79 Da toward the MW, compared with 189 Da for both the "Galacto" and mini-PEG moieties, suggesting this may be a broadly applicable approach to enhancing biodistribution of radiolabeled peptides.

  14. The Utility of [18F]DASA-23 for Molecular Imaging of Prostate Cancer with Positron Emission Tomography.

    PubMed

    Beinat, Corinne; Haywood, Tom; Chen, Yun-Sheng; Patel, Chirag B; Alam, Israt S; Murty, Surya; Gambhir, Sanjiv Sam

    2018-05-07

    There is a strong, unmet need for superior positron emission tomography (PET) imaging agents that are able to measure biochemical processes specific to prostate cancer. Pyruvate kinase M2 (PKM2) catalyzes the concluding step in glycolysis and is a key regulator of tumor growth and metabolism. Elevation of PKM2 expression was detected in Gleason 8-10 tumors compared to Gleason 6-7 carcinomas, indicating that PKM2 may potentially be a marker of aggressive prostate cancer. We have recently reported the development of a PKM2-specific radiopharmaceutical [ 18 F]DASA-23 and herein describe its evaluation in cell culture and preclinical models of prostate cancer. The cellular uptake of [ 18 F]DASA-23 was evaluated in a panel of prostate cancer cell lines and compared to that of [ 18 F]FDG. The specificity of [ 18 F]DASA-23 to measure PKM2 levels in cell culture was additionally confirmed through the use of PKM2-specific siRNA. PET imaging studies were then completed utilizing subcutaneous prostate cancer xenografts using either PC3 or DU145 cells in mice. [ 18 F]DASA-23 uptake values over 60-min incubation period in PC3, LnCAP, and DU145 respectively were 23.4 ± 4.5, 18.0 ± 2.1, and 53.1 ± 4.6 % tracer/mg protein. Transient reduction in PKM2 protein expression with siRNA resulted in a 50.1 % reduction in radiotracer uptake in DU145 cells. Small animal PET imaging revealed 0.86 ± 0.13 and 1.6 ± 0.2 % ID/g at 30 min post injection of radioactivity in DU145 and PC3 subcutaneous tumor bearing mice respectively. Herein, we evaluated a F-18-labeled PKM2-specific radiotracer, [ 18 F]DASA-23, for the molecular imaging of prostate cancer with PET. [ 18 F]DASA-23 revealed rapid and extensive uptake levels in cellular uptake studies of prostate cancer cells; however, there was only modest tumor uptake when evaluated in mouse subcutaneous tumor models.

  15. First experience with early dynamic (18)F-NaF-PET/CT in patients with chronic osteomyelitis.

    PubMed

    Freesmeyer, Martin; Stecker, Franz F; Schierz, Jan-Henning; Hofmann, Gunther O; Winkens, Thomas

    2014-05-01

    This study investigates whether early dynamic positron emission tomography/computed tomography (edPET/CT) using (18)F-sodium fluoride-((18)F-NaF) is feasible in depicting early phases of radiotracer distribution in patients with chronic osteomyelitis (COM). A total of 12 ed(18)F-NaF-PET/CT examinations were performed on 11 consecutive patients (2 female, 9 male; age 53 ± 12 years) in list mode over 5 min starting with radiopharmaceutical injection before standard late (18)F-NaF-PET/CT. Eight consecutive time intervals (frames) were reconstructed for each patient: four 15 s, then four 60 s. Several volumes of interest (VOI) were selected, representing the affected area as well as different reference areas within the bone and soft tissue. Maximum and mean ed standardized uptake values (edSUVmax, edSUVmean, respectively) were calculated in each VOI during each frame to measure early fluoride influx and accumulation. Results were compared between affected and non-affected (contralateral) bones. Starting in the 31-45 s frame, the affected bone area showed significantly higher edSUVmax and edSUVmean compared to the healthy contralateral region. The affected bone areas also significantly differed from non-affected contralateral regions in conventional late (18)F-NaF-PET/CT. This pilot study suggests that, in patients with COM, ed(18)F-NaF -PET offers additional information about early radiotracer distribution to standard (18)F-NaF -PET/CT, similar to a three-phase bone scan. The results should be validated in larger trials which directly compare ed(18)F-NaF-PET to a three-phase bone scan.

  16. Automated Synthesis of 18F-Fluoropropoxytryptophan for Amino Acid Transporter System Imaging

    PubMed Central

    Shih, I-Hong; Duan, Xu-Dong; Kong, Fan-Lin; Williams, Michael D.; Zhang, Yin-Han; Yang, David J.

    2014-01-01

    Objective. This study was to develop a cGMP grade of [18F]fluoropropoxytryptophan (18F-FTP) to assess tryptophan transporters using an automated synthesizer. Methods. Tosylpropoxytryptophan (Ts-TP) was reacted with K18F/kryptofix complex. After column purification, solvent evaporation, and hydrolysis, the identity and purity of the product were validated by radio-TLC (1M-ammonium acetate : methanol = 4 : 1) and HPLC (C-18 column, methanol : water = 7 : 3) analyses. In vitro cellular uptake of 18F-FTP and 18F-FDG was performed in human prostate cancer cells. PET imaging studies were performed with 18F-FTP and 18F-FDG in prostate and small cell lung tumor-bearing mice (3.7 MBq/mouse, iv). Results. Radio-TLC and HPLC analyses of 18F-FTP showed that the Rf and Rt values were 0.9 and 9 min, respectively. Radiochemical purity was >99%. The radiochemical yield was 37.7% (EOS 90 min, decay corrected). Cellular uptake of 18F-FTP and 18F-FDG showed enhanced uptake as a function of incubation time. PET imaging studies showed that 18F-FTP had less tumor uptake than 18F-FDG in prostate cancer model. However, 18F-FTP had more uptake than 18F-FDG in small cell lung cancer model. Conclusion. 18F-FTP could be synthesized with high radiochemical yield. Assessment of upregulated transporters activity by 18F-FTP may provide potential applications in differential diagnosis and prediction of early treatment response. PMID:25136592

  17. Automated synthesis of 18F-fluoropropoxytryptophan for amino acid transporter system imaging.

    PubMed

    Shih, I-Hong; Duan, Xu-Dong; Kong, Fan-Lin; Williams, Michael D; Yang, Kevin; Zhang, Yin-Han; Yang, David J

    2014-01-01

    This study was to develop a cGMP grade of [(18)F]fluoropropoxytryptophan ((18)F-FTP) to assess tryptophan transporters using an automated synthesizer. Tosylpropoxytryptophan (Ts-TP) was reacted with K(18)F/kryptofix complex. After column purification, solvent evaporation, and hydrolysis, the identity and purity of the product were validated by radio-TLC (1M-ammonium acetate : methanol = 4 : 1) and HPLC (C-18 column, methanol : water = 7 : 3) analyses. In vitro cellular uptake of (18)F-FTP and (18)F-FDG was performed in human prostate cancer cells. PET imaging studies were performed with (18)F-FTP and (18)F-FDG in prostate and small cell lung tumor-bearing mice (3.7 MBq/mouse, iv). Radio-TLC and HPLC analyses of (18)F-FTP showed that the Rf and Rt values were 0.9 and 9 min, respectively. Radiochemical purity was >99%. The radiochemical yield was 37.7% (EOS 90 min, decay corrected). Cellular uptake of (18)F-FTP and (18)F-FDG showed enhanced uptake as a function of incubation time. PET imaging studies showed that (18)F-FTP had less tumor uptake than (18)F-FDG in prostate cancer model. However, (18)F-FTP had more uptake than (18)F-FDG in small cell lung cancer model. (18)F-FTP could be synthesized with high radiochemical yield. Assessment of upregulated transporters activity by (18)F-FTP may provide potential applications in differential diagnosis and prediction of early treatment response.

  18. Prognostic Value of 18F-FLT PET in Patients with Neuroendocrine Neoplasms: A Prospective Head-to-Head Comparison with 18F-FDG PET and Ki-67 in 100 Patients.

    PubMed

    Johnbeck, Camilla B; Knigge, Ulrich; Langer, Seppo W; Loft, Annika; Berthelsen, Anne Kiil; Federspiel, Birgitte; Binderup, Tina; Kjaer, Andreas

    2016-12-01

    Neuroendocrine neoplasms (NENs) constitute a heterogeneous group of tumors arising in various organs and with a large span of aggressiveness and survival rates. The Ki-67 proliferation index is presently used as the key marker of prognosis, and treatment guidelines are largely based on this index. 3'-deoxy-3'- 18 F-fluorothymidine ( 18 F-FLT) is a proliferation tracer for PET imaging valuable in the monitoring of disease progression and treatment response in various types of cancer. However, until now only data from 10 patients with NEN were available in the literature. The aim of the present study was to investigate 18 F-FLT PET as a prognostic marker for NENs in comparison with 18 F-FDG PET and Ki-67 index. One hundred patients were PET-scanned with both 18 F-FLT and 18 F-FDG within the same week, and the prognostic value of a positive scan was examined in terms of progression-free survival (PFS) and overall survival (OS). The correlation between the Ki-67 index and 18 F-FLT uptake was also investigated. Thirty-seven percent of patients had a positive 18 F-FLT PET scan, and 49% had 18 F-FDG PET-positive foci. Patients with a high 18 F-FLT uptake had a significantly shorter OS and PFS than patients with low or no 18 F-FLT uptake. No correlation was found between Ki-67 index and 18 F-FLT uptake. In a multivariate analysis 18 F-FLT, 18 F-FDG, and Ki-67 all were significant prognostic markers of PFS. For OS, only 18 F-FDG and Ki-67 remained significant. 18 F-FLT PET has prognostic value in NEN patients but when 18 F-FDG PET and Ki-67 index are also available, a multivariate model revealed that 18 F-FLT PET only adds information regarding PFS but not OS, whereas 18 F-FDG PET remains predictive of both PFS and OS. However, a clinically robust algorithm including 18 F-FLT in addition to 18 F-FDG and Ki-67 could not be found. Accordingly, the exact role, if any, of 18 F-FLT PET in NENs remains to be established. © 2016 by the Society of Nuclear Medicine and Molecular

  19. Evaluation of 6-([18F] fluoroacetamido)-1-hexanoic-anilide (18F-FAHA) as imaging probe in tumor xenograft mice model

    NASA Astrophysics Data System (ADS)

    Li, Fiona; Cho, Sung Ju; Yu, Lihai; Hudson, Robert H. E.; Luyt, Leonard G.; Pin, Christopher L.; Kovacs, Michael S.; Koropatnick, James; Lee, Ting-Yim

    2016-03-01

    Alteration in genetic expression is as important as gene mutation in cancer development and proliferation. Epigenetic changes affect gene expression without altering the DNA sequence. Histone deacetylase (HDAC), an enzyme facilitating histone remodelling, can lead to silencing of tumor suppressor genes making HDAC inhibitors viable anticancer drugs against tumors with increased activity of the enzyme. In this study we evaluated 18F-fluroacetamido-1-hexanoicanilide (18F-FAHA), an artificial HDAC substrate, as imaging probe of HDAC activity of human tumor xenografts in immunocompromised host mice. Human breast and melanoma cell lines, MDA-MB-468 and MDA-MB-435 respectively, known to overexpress HDAC activity were xenografted into immunocompromised mice and HDAC activity was imaged using 18F-FAHA. The melanoma group was treated with saline, SAHA (suberoylanilide hydroxamic acid, an approved anticancer HDAC inhibitor) in DMSO, or DMSO as positive control. Tracer kinetic modelling and SUV were used to estimate HDAC activity from dynamic PET data. Both breast tumor and melanoma group showed great variability in binding rate constant (BRC) of 18F-FAHA suggesting highly variable inter- and intra-tumoral HDAC activity. For the SAHA treated melanoma group, HDAC activity, as monitored by BRC of 18F-FAHA, decreased more than the two (positive and negative) control groups but not tumor growth. Our preliminary study showed that noninvasive PET imaging with 18F-FAHA has the potential to identify patients for whom treatment with HDAC inhibitors are appropriate, to assess the effectiveness of that treatment as an early marker of target reduction, and also eliminate the need for invasive tissue biopsy to individualize treatment.

  20. Synthesis and preliminary evaluation of 18-(18)F-fluoro-4-thia-oleate as a PET probe of fatty acid oxidation.

    PubMed

    DeGrado, Timothy R; Bhattacharyya, Falguni; Pandey, Mukesh K; Belanger, Anthony P; Wang, Shuyan

    2010-08-01

    Fatty acid oxidation (FAO) is a major energy-providing process with important implications in cardiovascular, oncologic, neurologic, and metabolic diseases. A novel 4-thia oleate analog, 18-(18)F-fluoro-4-thia-oleate ((18)F-FTO), was evaluated in relationship to the previously developed palmitate analog 16-(18)F-fluoro-4-thia-palmitate ((18)F-FTP) as an FAO probe. (18)F-FTO was synthesized from a corresponding bromoester. Biodistribution and metabolite analysis studies were performed in rats. Preliminary small-animal PET studies were performed with (18)F-FTO and (18)F-FTP in rats. A practical synthesis of (18)F-FTO was developed, providing a radiotracer of high radiochemical purity (>99%). In fasted rats, myocardial uptake of (18)F-FTO (0.70 +/- 0.30% dose kg [body mass]/g [tissue mass]) was similar to that of (18)F-FTP at 30 min after injection. At 2 h, myocardial uptake of (18)F-FTO was maintained, whereas (18)F-FTP uptake in the heart was 82% reduced. Similar to (18)F-FTP, (18)F-FTO uptake by the heart was approximately 80% reduced at 30 min by pretreatment of rats with the CPT-I inhibitor etomoxir. Folch-type extraction analyses showed 70-90% protein-bound fractions in the heart, liver, and skeletal muscle, consistent with efficient trafficking of (18)F-FTO to the mitochondrion with subsequent metabolism to protein-bound species. Preliminary small-animal PET studies showed rapid blood clearance and avid extraction of (18)F-FTO and of (18)F-FTP into the heart and liver. Images of (18)F-FTO accumulation in the rat myocardium were clearly superior to those of (18)F-FTP. (18)F-FTO is shown to be a promising metabolically trapped FAO probe that warrants further evaluation.

  1. Brain energy metabolism and neuroinflammation in ageing APP/PS1-21 mice using longitudinal 18F-FDG and 18F-DPA-714 PET imaging.

    PubMed

    Takkinen, Jatta S; López-Picón, Francisco R; Al Majidi, Rana; Eskola, Olli; Krzyczmonik, Anna; Keller, Thomas; Löyttyniemi, Eliisa; Solin, Olof; Rinne, Juha O; Haaparanta-Solin, Merja

    2017-08-01

    Preclinical animal model studies of brain energy metabolism and neuroinflammation in Alzheimer's disease have produced conflicting results, hampering both the elucidation of the underlying disease mechanism and the development of effective Alzheimer's disease therapies. Here, we aimed to quantify the relationship between brain energy metabolism and neuroinflammation in the APP/PS1-21 transgenic mouse model of Alzheimer's disease using longitudinal in vivo 18 F-FDG and 18 F-DPA-714) PET imaging and ex vivo brain autoradiography. APP/PS1-21 (TG, n = 9) and wild type control mice (WT, n = 9) were studied longitudinally every third month from age 6 to 15 months with 18 F-FDG and 18 F-DPA-714 with a one-week interval between the scans. Additional TG (n = 52) and WT (n = 29) mice were used for ex vivo studies. In vivo, the 18 F-FDG SUVs were lower and the 18 F-DPA-714 binding ratios relative to the cerebellum were higher in the TG mouse cortex and hippocampus than in WT mice at age 12 to 15 months ( p < 0.05). The ex vivo cerebellum binding ratios supported the results of the in vivo 18 F-DPA-714 studies but not the 18 F-FDG studies. This longitudinal PET study demonstrated decreased energy metabolism and increased inflammation in the brains of APP/PS1-21 mice compared to WT mice.

  2. The Origin of the s, p, d, f Orbital Labels

    ERIC Educational Resources Information Center

    Jensen, William B.

    2007-01-01

    The theory of s, p, d and f dealing with the line spectra of the alkali metals during the period 1881 based on analogies with the harmonic ratios of sound is described. Friedrich Hund followed Bohr's practice of labelling the various shells and subshells by replacing the secondary quantum number with the series notations (s, p, d, and f), which…

  3. 18F-PSMA-1007 PET/CT at 60 and 120 minutes in patients with prostate cancer: biodistribution, tumour detection and activity kinetics.

    PubMed

    Rahbar, Kambiz; Afshar-Oromieh, Ali; Bögemann, Martin; Wagner, Stefan; Schäfers, Michael; Stegger, Lars; Weckesser, Matthias

    2018-03-14

    PSMA-targeted PET in patients with prostate cancer (PCa) has a significant impact on treatment decisions. By far the most frequently used PSMA ligand is 68 Ga-labelled PSMA-11. However, due to the availability of larger amounts of activity, 18 F-labelled PSMA ligands are of major interest. The aim of the present study was to evaluate the biodistribution and performance of the novel 18 F-labelled ligand PSMA-1007 at two different time points. This retrospective analysis included 40 consecutive patients (mean age 68.7 ± 8.1 years) referred for PSMA PET/CT. 18 F-PSMA-1007 PET/CT was performed for localization of biochemical relapse, primary staging or therapy follow-up. Circular regions of interest were placed on representative slices of the liver, spleen, kidney, abdominal aortic blood pool, bone marrow (fourth lumbar vertebral body), urinary bladder and gluteus muscle at 60 and 120 min after injection. In malignant lesions the maximum standardized uptake (SUV max ) was measured within volumes of interest at both time points. All SUVs at 60 min were compared with those at 120 min after injection. The activity in the blood pool, urinary bladder and gluteus muscle was very low and decreased significantly over time (P < 0.001). Uptake in the liver, spleen and kidney showed a significant increase over time and uptake in the bone marrow remained stable. Overall, 135 PCa lesions were detected at 60 min and 136 lesions at 120 min after injection. The median SUV max increased significantly (P < 0.001) from 10.98 to 15.51 between 60 and 120 min. PCa lesions show a significant increase in 18 F-PSMA-1007 uptake at 120 min compared with 60 min after injection. In addition, accumulation of the tracer in the urinary bladder was very low leading to improved contrast of adjacent PCa lesions. Increasing accumulation in the liver may limit the sensitivity of the tracer in detecting liver metastases.

  4. Synthesis and In Vitro Evaluation of 5-[18F]Fluoroalkyl Pyrimidine Nucleosides for Molecular Imaging of Herpes Simplex Virus Type-1 Thymidine Kinase Reporter Gene Expression

    PubMed Central

    Chacko, Ann-Marie; Qu, Wenchao; Kung, Hank F.

    2014-01-01

    Two novel series of 5-fluoroalkyl-2′-deoxyuridines (FPrDU, FBuDU, FPeDU) and 2′-fluoro-2′-deoxy-5-fluoroalkylarabinouridines (FFPrAU, FFBuAU, FFPeAU), having three, four or five methylene units (propyl, butyl, or pentyl) at C-5, were prepared and tested as reporter probes for imaging HSV1-tk gene expression. The Negishi coupling methodology was employed to efficiently synthesize the radiolabeling precursors. All six 5-[18F]fluoroalkyl pyrimidines were prepared readily from 3-N-benzoyl-3′,5′-di-O-benzoyl-protected 5-O-mesylate precursors in 17–35% radiochemical yield (decay-corrected). In vitro studies highlighted that all six [18F]labeled nucleosides selectively accumulated in cells expressing the HSV1-TK protein, with negligible uptake in control cells. [18F]FPrDU, [18F]FBuDU, [18F]FPeDU, and [18F]FFBuAU had the best uptake profiles. Despite selective accumulation in HSV1-tk expressing cells, all 5-fluoroalkyl pyrimidine nucleosides had low to negligible cytotoxic activity (CC50>1000–209 μM). Ultimately, results demonstrated that 5-[18F]fluoropropyl, [18F]fluorobutyl, and [18F]fluoropentyl pyrimidine nucleosides have potential as in vivo HSV1-TK PET reporter probes over a dynamic range of reporter gene expression levels. PMID:18800764

  5. A simple microfluidic platform for rapid and efficient production of the radiotracer [18F]fallypride.

    PubMed

    Zhang, Xin; Liu, Fei; Knapp, Karla-Anne; Nickels, Michael L; Manning, H Charles; Bellan, Leon M

    2018-05-01

    Herein, we report the development of a simple, high-throughput and efficient microfluidic system for synthesizing radioactive [18F]fallypride, a PET imaging radiotracer widely used in medical research. The microfluidic chip contains all essential modules required for the synthesis and purification of radioactive fallypride. The radiochemical yield of the tracer is sufficient for multiple animal injections for preclinical imaging studies. To produce the on-chip concentration and purification columns, we employ a simple "trapping" mechanism by inserting rows of square pillars with predefined gaps near the outlet of microchannel. Microspheres with appropriate functionality are suspended in solution and loaded into the microchannels to form columns for radioactivity concentration and product purification. Instead of relying on complicated flow control elements (e.g., micromechanical valves requiring complex external pneumatic actuation), external valves are utilized to control transfer of the reagents between different modules. The on-chip ion exchange column can efficiently capture [18F]fluoride with negligible loss (∼98% trapping efficiency), and subsequently release a burst of concentrated [18F]fluoride to the reaction cavity. A thin layer of PDMS with a small hole in the center facilitates rapid and reliable water evaporation (with the aid of azeotropic distillation and nitrogen flow) while reducing fluoride loss. During the solvent exchange and fluorination reaction, the entire chip is uniformly heated to the desired temperature using a hot plate. All aspects of the [18F]fallypride synthesis were monitored by high-performance liquid chromatography (HPLC) analysis, resulting in labelling efficiency in fluorination reaction ranging from 67-87% (n = 5). Moreover, after isolating unreacted [18F]fluoride, remaining fallypride precursor, and various by-products via an on-chip purification column, the eluted [18F]fallypride is radiochemically pure and of a sufficient

  6. Imaging of amyloid deposition in human brain using positron emission tomography and [18F]FACT: comparison with [11C]PIB.

    PubMed

    Ito, Hiroshi; Shinotoh, Hitoshi; Shimada, Hitoshi; Miyoshi, Michie; Yanai, Kazuhiko; Okamura, Nobuyuki; Takano, Harumasa; Takahashi, Hidehiko; Arakawa, Ryosuke; Kodaka, Fumitoshi; Ono, Maiko; Eguchi, Yoko; Higuchi, Makoto; Fukumura, Toshimitsu; Suhara, Tetsuya

    2014-04-01

    The characteristic neuropathological changes in Alzheimer's disease (AD) are deposition of amyloid senile plaques and neurofibrillary tangles. The (18)F-labeled amyloid tracer, [(18)F]2-[(2-{(E)-2-[2-(dimethylamino)-1,3-thiazol-5-yl]vinyl}-1,3-benzoxazol-6-yl)oxy]-3-fluoropropan-1-ol (FACT), one of the benzoxazole derivatives, was recently developed. In the present study, deposition of amyloid senile plaques was measured by positron emission tomography (PET) with both [(11)C]Pittsburgh compound B (PIB) and [(18)F]FACT in the same subjects, and the regional uptakes of both radiotracers were directly compared. Two PET scans, one of each with [(11)C]PIB and [(18)F]FACT, were performed sequentially on six normal control subjects, two mild cognitive impairment (MCI) patients, and six AD patients. The standardized uptake value ratio of brain regions to the cerebellum was calculated with partial volume correction using magnetic resonance (MR) images to remove the effects of white matter accumulation. No significant differences in the cerebral cortical uptake were observed between normal control subjects and AD patients in [(18)F]FACT studies without partial volume correction, while significant differences were observed in [(11)C]PIB. After partial volume correction, the cerebral cortical uptake was significantly larger in AD patients than in normal control subjects for [(18)F]FACT studies as well as [(11)C]PIB. Relatively lower uptakes of [(11)C]PIB in distribution were observed in the medial side of the temporal cortex and in the occipital cortex as compared with [(18)F]FACT. Relatively higher uptake of [(11)C]PIB in distribution was observed in the frontal and parietal cortices. Since [(18)F]FACT might bind more preferentially to dense-cored amyloid deposition, regional differences in cerebral cortical uptake between [(11)C]PIB and [(18)F]FACT might be due to differences in regional distribution between diffuse and dense-cored amyloid plaque shown in the

  7. Fluorine-18-Labeled Fluoromisonidazole Positron Emission and Computed Tomography-Guided Intensity-Modulated Radiotherapy for Head and Neck Cancer: A Feasibility Study

    PubMed Central

    Lee, Nancy Y.; Mechalakos, James G.; Nehmeh, Sadek; Lin, Zhixiong; Squire, Olivia D.; Cai, Shangde; Chan, Kelvin; Zanzonico, Pasquale B.; Greco, Carlo; Ling, Clifton C.; Humm, John L.; Schöder, Heiko

    2010-01-01

    Purpose Hypoxia renders tumor cells radioresistant, limiting locoregional control from radiotherapy (RT). Intensity-modulated RT (IMRT) allows for targeting of the gross tumor volume (GTV) and can potentially deliver a greater dose to hypoxic subvolumes (GTVh) while sparing normal tissues. A Monte Carlo model has shown that boosting the GTVh increases the tumor control probability. This study examined the feasibility of fluorine-18labeled fluoromisonidazole positron emission tomography/computed tomography (18F-FMISO PET/CT)–guided IMRT with the goal of maximally escalating the dose to radioresistant hypoxic zones in a cohort of head and neck cancer (HNC) patients. Methods and Materials 18F-FMISO was administered intravenously for PET imaging. The CT simulation, fluorodeoxyglucose PET/CT, and 18F-FMISO PET/CT scans were co-registered using the same immobilization methods. The tumor boundaries were defined by clinical examination and available imaging studies, including fluorodeoxyglucose PET/CT. Regions of elevated 18F-FMISO uptake within the fluorodeoxyglucose PET/CT GTV were targeted for an IMRT boost. Additional targets and/or normal structures were contoured or transferred to treatment planning to generate 18F-FMISO PET/CT-guided IMRT plans. Results The heterogeneous distribution of 18F-FMISO within the GTV demonstrated variable levels of hypoxia within the tumor. Plans directed at performing 18F-FMISO PET/CT–guided IMRT for 10 HNC patients achieved 84 Gy to the GTVh and 70 Gy to the GTV, without exceeding the normal tissue tolerance. We also attempted to deliver 105 Gy to the GTVh for 2 patients and were successful in 1, with normal tissue sparing. Conclusion It was feasible to dose escalate the GTVh to 84 Gy in all 10 patients and in 1 patient to 105 Gy without exceeding the normal tissue tolerance. This information has provided important data for subsequent hypoxia-guided IMRT trials with the goal of further improving locoregional control in HNC

  8. Influence of P-Glycoprotein Inhibition or Deficiency at the Blood-Brain Barrier on (18)F-2-Fluoro-2-Deoxy-D-glucose ( (18)F-FDG) Brain Kinetics.

    PubMed

    Tournier, Nicolas; Saba, Wadad; Goutal, Sébastien; Gervais, Philippe; Valette, Héric; Scherrmann, Jean-Michel; Bottlaender, Michel; Cisternino, Salvatore

    2015-05-01

    The fluorinated D-glucose analog (18)F-2-fluoro-2-deoxy-D-glucose ((18)F-FDG) is the most prevalent radiopharmaceutical for positron emission tomography (PET) imaging. P-Glycoprotein's (P-gp, MDR1, and ABCB1) function in various cancer cell lines and tumors was shown to impact (18)F-FDG incorporation, suggesting that P-gp function at the blood-brain barrier may also modulate (18)F-FDG brain kinetics. We tested the influence of P-gp inhibition using the cyclosporine analog valspodar (PSC833; 5 μM) on the uptake of (18)F-FDG in standardized human P-gp-overexpressing cells (MDCKII-MDR1). Consequences for (18)F-FDG brain kinetics were then assessed using (i) (18)F-FDG PET imaging and suitable kinetic modelling in baboons without or with P-gp inhibition by intravenous cyclosporine infusion (15 mg kg(-1) h(-1)) and (ii) in situ brain perfusion in wild-type and P-gp/Bcrp (breast cancer resistance protein) knockout mice and controlled D-glucose exposure to the brain. In vitro, the time course of (18)F-FDG uptake in MDR1 cells was influenced by the presence of valspodar in the absence of D-glucose but not in the presence of high D-glucose concentration. PET analysis revealed that P-gp inhibition had no significant impact on estimated brain kinetics parameters K 1, k 2, k 3, V T , and CMRGlc. The lack of P-gp effect on in vivo (18)F-FDG brain distribution was confirmed in P-gp/Bcrp-deficient mice. P-gp inhibition indirectly modulates (18)F-FDG uptake into P-gp-overexpressing cells, possibly through differences in the energetic cell level state. (18)F-FDG is not a P-gp substrate at the BBB and (18)F-FDG brain kinetics as well as estimated brain glucose metabolism are influenced by neither P-gp inhibition nor P-gp/Bcrp deficiencies in baboon and mice, respectively.

  9. Imaging of prostate cancer with PET/CT using 18F-Fluorocholine

    PubMed Central

    Vali, Reza; Loidl, Wolfgang; Pirich, Christian; Langesteger, Werner; Beheshti, Mohsen

    2015-01-01

    While 18F-Fluorodeoxyglucose (18F-FDG) Positron-Emission Tomography (PET) has limited value in prostate cancer (PCa), it may be useful for specific subgroups of PCa patients with hormone-resistant poorly differentiated cell types. 18F-Fluorocholine (18F-FCH) PET/CT has been increasingly used in primary and recurrent PCa and has been shown to add valuable information. Although there is a correlation between the foci of activity and the areas of malignancy in the prostate gland, the clinical value of 18F-FCH is still controversial for detection of the malignant focus in the prostate. For the T-staging of PCa at diagnosis the value of 18F-FCH is limited. This is probably due to limited resolution of PET system and positive findings in benign prostate diseases. Conversely, 18F-FCH PET/CT is a promising imaging modality for the delineation of local and distant nodal recurrence and bone metastases and is poised to have an impact on therapy management. In this review, recent studies of 18F-FCH PET/CT in PCa are summarized. PMID:25973332

  10. Label Review Training: Module 1: Label Basics, Page 18

    EPA Pesticide Factsheets

    This module of the pesticide label review training provides basic information about pesticides, their labeling and regulation, and the core principles of pesticide label review. This section discusses the types of labels.

  11. A comparison of image contrast with 64Cu-labeled long circulating liposomes and 18F-FDG in a murine model of mammary carcinoma

    PubMed Central

    Wong, Andrew W; Ormsby, Eleanor; Zhang, Hua; Seo, Jai Woong; Mahakian, Lisa M; Caskey, Charles F; Ferrara, Katherine W

    2013-01-01

    Conjugation of the 64Cu PET radioisotope (t1/2 = 12.7 hours) to long circulating liposomes enables long term liposome tracking. To evaluate the potential clinical utility of this radiotracer in diagnosis and therapeutic guidance, we compare image contrast, tumor volume, and biodistribution of 64Cu-liposomes to metrics obtained with the dominant clinical tracer, 18F-FDG. Twenty four female FVB mice with MET1 mammary carcinoma tumor grafts were examined. First, serial PET images were obtained with the 18F-FDG radiotracer at 0.5 hours after injection and with the 64Cu-liposome radiotracer at 6, 18, 24, and 48 hours after injection (n = 8). Next, paired imaging and histology were obtained at four time points: 0.5 hours after 18F-FDG injection and 6, 24, and 48 hours after 64Cu-liposome injection (n = 16). Tissue biodistribution was assessed with gamma counting following necropsy and tumors were paraffin embedded, sectioned, and stained with hematoxylin and eosin. The contrast ratio of images obtained using 18F-FDG was 0.88 ± 0.01 (0.5 hours after injection), whereas with the 64Cu-liposome radiotracer the contrast ratio was 0.78 ± 0.01, 0.89 ± 0.01, 0.88 ± 0.01, and 0.94 ± 0.01 at 6, 18, 24, and 48 hours, respectively. Estimates of tumor diameter were comparable between 64Cu-liposomes and 18F-FDG, 64Cu-liposomes and necropsy, and 64Cu-liposomes and ultrasound with Pearson’s r-squared values of 0.79, 0.79, and 0.80, respectively. Heterogeneity of tumor tracer uptake was observed with both tracers, correlating with regions of necrosis on histology. The average tumor volume of 0.41 ± 0.05 cc measured with 64Cu-liposomes was larger than that estimated with 18F-FDG (0.28 ± 0.04 cc), with this difference apparently resulting primarily from accumulation of the radiolabeled particles in the pro-angiogenic tumor rim. The imaging of radiolabeled nanoparticles can facilitate tumor detection, identification of tumor margins, therapeutic evaluation and interventional

  12. Radiolabeling and in vitro and in vivo characterization of [18F]FB-[R(8,15,21), L17]-VIP as a PET imaging agent for tumor overexpressed VIP receptors.

    PubMed

    Cheng, Dengfeng; Yin, Duanzhi; Li, Gucai; Wang, Mingwei; Li, Shiqiang; Zheng, Mingqiang; Cai, Hancheng; Wang, Yongxian

    2006-12-01

    In an effort to develop a peptide-based radiopharmaceutical for the detection of tumors overexpressed vasoactive intestinal peptide receptors with positron emission tomography, we have prepared a novel [R(8,15,21), L17]-VIP peptide for 18F-labeling. This peptide inhibited 125I-VIP binding to rats lung membranes with high affinity [half-maximal inhibitory concentrations (IC50) of 0.12 nm]. Additionally, [R(8,15,21), L17]-VIP showed higher stability than native vasoactive intestinal peptide in vivo of mice. With N-succinimidyl 4-[18F] fluorobenzoate as labeling prosthetic group, [18F]FB-[R(8,15,21), L17]-VIP was obtained in >99% radiochemical purity within 100 min in decay-for-corrected radiochemical yield of 33.6 +/- 3% (n = 5) and a specific radioactivity 255 GBq/micromol at the end of synthesis. Stability of [18F]FB-[R(8,15,21), L17]-VIP in vitro and in vivo were investigated. Biodistribution of this trace was carried out in mice with induced C26 colorectal tumor. Fast clearance of [18F]FB-[R(8,15,21), L17]-VIP from non-target tissues and specific uptakes by tumors realized higher tumor-to-muscle ratio (3.55) and tumor-to-blood ratio (2.37) 60 min postinjection. Clear difference was observed between the blocking and unblocking experiments in biodistribution and whole body radioautography. [18F]FB-[R(8,15,21), L17]-VIP has demonstrated its potential for diagnosing tumors overexpressed vasoactive intestinal peptide receptors both in vitro and in vivo.

  13. Automated synthesis of N-(2-[18 F]Fluoropropionyl)-l-glutamic acid as an amino acid tracer for tumor imaging on a modified [18 F]FDG synthesis module.

    PubMed

    Liu, Shaoyu; Sun, Aixia; Zhang, Zhanwen; Tang, Xiaolan; Nie, Dahong; Ma, Hui; Jiang, Shende; Tang, Ganghua

    2017-06-15

    N-(2-[ 18 F]Fluoropropionyl)-l-glutamic acid ([ 18 F]FPGLU) is a potential amino acid tracer for tumor imaging with positron emission tomography. However, due to the complicated multistep synthesis, the routine production of [ 18 F]FPGLU presents many challenging laboratory requirements. To simplify the synthesis process of this interesting radiopharmaceutical, an efficient automated synthesis of [ 18 F]FPGLU was performed on a modified commercial fluorodeoxyglucose synthesizer via a 2-step on-column hydrolysis procedure, including 18 F-fluorination and on-column hydrolysis reaction. [ 18 F]FPGLU was synthesized in 12 ± 2% (n = 10, uncorrected) radiochemical yield based on [ 18 F]fluoride using the tosylated precursor 2. The radiochemical purity was ≥98%, and the overall synthesis time was 35 minutes. To further optimize the radiosynthesis conditions of [ 18 F]FPGLU, a brominated precursor 3 was also used for the preparation of [ 18 F]FPGLU, and the improved radiochemical yield was up to 20 ± 3% (n = 10, uncorrected) in 35 minutes. Moreover, all these results were achieved using the similar on-column hydrolysis procedure on the modified fluorodeoxyglucose synthesis module. Copyright © 2017 John Wiley & Sons, Ltd.

  14. Multiparametric [18F]Fluorodeoxyglucose/ [18F]Fluoromisonidazole Positron Emission Tomography/ Magnetic Resonance Imaging of Locally Advanced Cervical Cancer for the Non-Invasive Detection of Tumor Heterogeneity: A Pilot Study

    PubMed Central

    Andrzejewski, Piotr; Baltzer, Pascal; Polanec, Stephan H.; Sturdza, Alina; Georg, Dietmar; Helbich, Thomas H.; Karanikas, Georgios; Grimm, Christoph; Polterauer, Stephan; Poetter, Richard; Wadsak, Wolfgang; Mitterhauser, Markus; Georg, Petra

    2016-01-01

    Objectives To investigate fused multiparametric positron emission tomography/magnetic resonance imaging (MP PET/MRI) at 3T in patients with locally advanced cervical cancer, using high-resolution T2-weighted, contrast-enhanced MRI (CE-MRI), diffusion-weighted imaging (DWI), and the radiotracers [18F]fluorodeoxyglucose ([18F]FDG) and [18F]fluoromisonidazol ([18F]FMISO) for the non-invasive detection of tumor heterogeneity for an improved planning of chemo-radiation therapy (CRT). Materials and Methods Sixteen patients with locally advanced cervix were enrolled in this IRB approved and were examined with fused MP [18F]FDG/ [18F]FMISO PET/MRI and in eleven patients complete data sets were acquired. MP PET/MRI was assessed for tumor volume, enhancement (EH)-kinetics, diffusivity, and [18F]FDG/ [18F]FMISO-avidity. Descriptive statistics and voxel-by-voxel analysis of MRI and PET parameters were performed. Correlations were assessed using multiple correlation analysis. Results All tumors displayed imaging parameters concordant with cervix cancer, i.e. type II/III EH-kinetics, restricted diffusivity (median ADC 0.80x10-3mm2/sec), [18F]FDG- (median SUVmax16.2) and [18F]FMISO-avidity (median SUVmax3.1). In all patients, [18F]FMISO PET identified the hypoxic tumor subvolume, which was independent of tumor volume. A voxel-by-voxel analysis revealed only weak correlations between the MRI and PET parameters (0.05–0.22), indicating that each individual parameter yields independent information and the presence of tumor heterogeneity. Conclusion MP [18F]FDG/ [18F]FMISO PET/MRI in patients with cervical cancer facilitates the acquisition of independent predictive and prognostic imaging parameters. MP [18F]FDG/ [18F]FMISO PET/MRI enables insights into tumor biology on multiple levels and provides information on tumor heterogeneity, which has the potential to improve the planning of CRT. PMID:27167829

  15. Multiparametric [18F]Fluorodeoxyglucose/ [18F]Fluoromisonidazole Positron Emission Tomography/ Magnetic Resonance Imaging of Locally Advanced Cervical Cancer for the Non-Invasive Detection of Tumor Heterogeneity: A Pilot Study.

    PubMed

    Pinker, Katja; Andrzejewski, Piotr; Baltzer, Pascal; Polanec, Stephan H; Sturdza, Alina; Georg, Dietmar; Helbich, Thomas H; Karanikas, Georgios; Grimm, Christoph; Polterauer, Stephan; Poetter, Richard; Wadsak, Wolfgang; Mitterhauser, Markus; Georg, Petra

    2016-01-01

    To investigate fused multiparametric positron emission tomography/magnetic resonance imaging (MP PET/MRI) at 3T in patients with locally advanced cervical cancer, using high-resolution T2-weighted, contrast-enhanced MRI (CE-MRI), diffusion-weighted imaging (DWI), and the radiotracers [18F]fluorodeoxyglucose ([18F]FDG) and [18F]fluoromisonidazol ([18F]FMISO) for the non-invasive detection of tumor heterogeneity for an improved planning of chemo-radiation therapy (CRT). Sixteen patients with locally advanced cervix were enrolled in this IRB approved and were examined with fused MP [18F]FDG/ [18F]FMISO PET/MRI and in eleven patients complete data sets were acquired. MP PET/MRI was assessed for tumor volume, enhancement (EH)-kinetics, diffusivity, and [18F]FDG/ [18F]FMISO-avidity. Descriptive statistics and voxel-by-voxel analysis of MRI and PET parameters were performed. Correlations were assessed using multiple correlation analysis. All tumors displayed imaging parameters concordant with cervix cancer, i.e. type II/III EH-kinetics, restricted diffusivity (median ADC 0.80x10-3mm2/sec), [18F]FDG- (median SUVmax16.2) and [18F]FMISO-avidity (median SUVmax3.1). In all patients, [18F]FMISO PET identified the hypoxic tumor subvolume, which was independent of tumor volume. A voxel-by-voxel analysis revealed only weak correlations between the MRI and PET parameters (0.05-0.22), indicating that each individual parameter yields independent information and the presence of tumor heterogeneity. MP [18F]FDG/ [18F]FMISO PET/MRI in patients with cervical cancer facilitates the acquisition of independent predictive and prognostic imaging parameters. MP [18F]FDG/ [18F]FMISO PET/MRI enables insights into tumor biology on multiple levels and provides information on tumor heterogeneity, which has the potential to improve the planning of CRT.

  16. Utility of 18 F-FDG PET/CT scan to diagnose the etiology of fever of unknown origin in patients on dialysis.

    PubMed

    Tek Chand, Kalawat; Chennu, Krishna Kishore; Amancharla Yadagiri, Lakshmi; Manthri Gupta, Ranadheer; Rapur, Ram; Vishnubotla, Siva Kumar

    2017-04-01

    Studies on fever of unknown origin (FUO) in patients of chronic kidney disease and end stage renal disease patients on dialysis were not many. In this study, we used 18 F-FDG PET/CT scan whole body survey for detection of hidden infection, in patients on dialysis, labelled as FUO. In this retrospective study, 20 patients of end stage renal disease on dialysis were investigated for the cause of FUO using 18F-FDG PET/CT scan. All these patients satisfied the definition of FUO as defined by Petersdorf and Beeson. Any focal abnormal site of increased FDG concentration detected by PET/CT, either a solitary or multiple lesions was documented and at least one of the detected abnormal sites of radio tracer concentration was further examined for histopathology. All patients were on renal replacement therapy. Of these, 18 were on hemodialysis and two were on peritoneal dialysis. 18F-FDG PET/CT scan showed metabolically active lesions in 15 patients and metabolically quiescent in five patients. After 18F-FDG PET/CT scan all, but one patient had a change in treatment for fever. Anti-tuberculous treatment was given in 15 patients, antibiotics in four patients and anti-malaria treatment in one patient. The present study is first study of 18F-FDG PET/CT scan in patients of end stage renal disease on dialysis with FUO. The study showed that the 18 F FDG PET/CT scan may present an opportunity to attain the diagnosis in end stage renal disease patients on dialysis with FUO. © 2016 International Society for Hemodialysis.

  17. A multicenter clinical trial on the diagnostic value of dual-tracer PET/CT in pulmonary lesions using 3'-deoxy-3'-18F-fluorothymidine and 18F-FDG.

    PubMed

    Tian, Jiahe; Yang, Xiaofeng; Yu, Lijuan; Chen, Ping; Xin, Jun; Ma, Liming; Feng, Huiru; Tan, Yieyin; Zhao, Zhoushe; Wu, Wenkai

    2008-02-01

    Some new radiotracers might add useful information and improve diagnostic confidence of (18)F-FDG imaging in tumors. A multicenter clinical trial was designed to investigate the diagnostic performance of dual-tracer ((18)F-FDG and 3'-deoxy-3'-(18)F-fluorothymidine [(18)F-FLT]) PET/CT in pulmonary nodules. Fifty-five patients underwent dual-tracer imaging in 6 imaging centers using the same models of equipment and standardized protocols. The images were interpreted by a collective group of readers who were unaware of the clinical data. The diagnostic performance using either tracer alone or dual-tracers together, with or without CT, was compared. The histological diagnosis or clinical findings in a 12-mo follow-up period served as the standard of truth. In 16 patients with malignant tumor, 16 with tuberculosis, and 23 with other benign lesions, the sensitivity and specificity of (18)F-FDG and (18)F-FLT were 87.5% and 58.97% and 68.75% and 76.92%, respectively. The combination of dual-tracer PET/CT improved the sensitivity and specificity up to 100% and 89.74%. The 3 subgroups of patients could be best separated when the (18)F-FLT/(18)F-FDG standardized uptake value ratio of 0.4-0.90 was used as the threshold. By reflecting different biologic features, the dual-tracer PET/CT using (18)F-FDG and (18)F-FLT favorably affected the diagnosis of lung nodules.

  18. Mapping the binding domain of the F18 fimbrial adhesin.

    PubMed

    Smeds, A; Pertovaara, M; Timonen, T; Pohjanvirta, T; Pelkonen, S; Palva, A

    2003-04-01

    F18 fimbrial Esherichia coli strains are associated with porcine postweaning diarrhea and pig edema disease. Recently, the FedF subunit was identified as the adhesin of the F18 fimbriae. In this study, adhesion domains of FedF were further studied by constructing deletions within the fedF gene and expressing FedF proteins with deletions either together with the other F18 fimbrial subunits or as fusion proteins tagged with maltose binding protein. The region essential for adhesion to porcine intestinal epithelial cells was mapped between amino acid residues 60 and 109 of FedF. To map the binding domain even more closely, all eight charged amino acid residues within this region were independently replaced by alanine. Three of these single point mutants expressing F18 fimbriae exhibited significantly diminished capabilities to adhere to porcine epithelial cells in vitro. In addition, a triple point mutation and a double point mutation completely abolished receptor adhesiveness. The result further confirmed that the region between amino acid residues 60 and 109 is essential for the binding of F18 fimbriae to their receptor. In addition, the adhesion capability of the binding domain was eliminated after treatment with iodoacetamide, suggesting the formation of a disulfide bridge between Cys-63 and Cys-83, whereas Cys-111 and Cys-116 could be deleted without affecting the binding ability of FedF.

  19. Molecular imaging of σ receptors: synthesis and evaluation of the potent σ1 selective radioligand [18F]fluspidine.

    PubMed

    Fischer, Steffen; Wiese, Christian; Maestrup, Eva Grosse; Hiller, Achim; Deuther-Conrad, Winnie; Scheunemann, Matthias; Schepmann, Dirk; Steinbach, Jörg; Wünsch, Bernhard; Brust, Peter

    2011-03-01

    Neuroimaging of σ(1) receptors in the human brain has been proposed for the investigation of the pathophysiology of neurodegenerative and psychiatric diseases. However, there is a lack of suitable (18)F-labelled PET radioligands for that purpose. The selective σ(1) receptor ligand [(18)F]fluspidine (1'-benzyl-3-(2-[(18)F]fluoroethyl)-3H-spiro[[2]benzofuran-1,4'-piperidine]) was synthesized by nucleophilic (18)F(-) substitution of the tosyl precursor. In vitro receptor binding affinity and selectivity were assessed by radioligand competition in tissue homogenate and autoradiographic approaches. In female CD-1 mice, in vivo properties of [(18)F]fluspidine were evaluated by ex vivo brain section imaging and organ distribution of intravenously administered radiotracer. Target specificity was validated by organ distribution of [(18)F]fluspidine after treatment with 1 mg/kg i.p. of the σ receptor antagonist haloperidol or the emopamil binding protein (EBP) inhibitor tamoxifen. In vitro metabolic stability and in vivo metabolism were investigated by LC-MS(n) and radio-HPLC analysis. [(18)F]Fluspidine was obtained with a radiochemical yield of 35-45%, a radiochemical purity of ≥ 99.6% and a specific activity of 150-350 GBq/μmol (n = 6) within a total synthesis time of 90-120 min. In vitro, fluspidine bound specifically and with high affinity to σ(1) receptors (K (i) = 0.59 nM). In mice, [(18)F]fluspidine rapidly accumulated in brain with uptake values of 3.9 and 4.7%ID/g and brain to blood ratios of 7 and 13 at 5 and 30 min after intravenous application of the radiotracer, respectively. By ex vivo autoradiography of brain slices, resemblance between binding site occupancy of [(18)F]fluspidine and the expression of σ(1) receptors was shown. The radiotracer uptake in the brain as well as in peripheral σ(1) receptor expressing organs was significantly inhibited by haloperidol but not by tamoxifen. Incubation with rat liver microsomes led to a fast

  20. F18-FDG coincidence-PET in patients with suspected gynecological malignancy.

    PubMed

    Zor, E; Stokkel, M P; Ozalp, S; Vardareli, E; Yalçin, O Tarik; Ak, I

    2006-07-01

    To assess the role of F18-FDG imaging with a dual-head coincidence mode gamma camera (Co-PET) in identifying malignant tumors in patients with a suspicious adnexal mass depicted by conventional imaging methods. F18-FDG Co-PET was performed preoperatively in 18 women (mean age 56.38 years) with suspected malignant gynecologic tumors according to clinical and abdomino-pelvic/transvaginal ultrasound or computed tomography findings. Exploratory laparotomy was performed in all patients within the 10 days post-F18-FDG Co-PET study, and the definitive diagnosis of the adnexal masses was established by histopathological examination. Histopathological examinations of the surgically excised adnexal masses revealed eight malignant, one borderline, and nine benign neoplastic tumors. Four benign tumors had no F18-FDG uptake, while the remaining five tumors, all leiomyomas, showed mild FDG accumulation. Eight malignant tumors showed intense F18-FDG uptake. Sensitivity, specificity, PPV, and NPV of F18-FDG co-PET in differentiating benign from malign adnexal masses were 88%, 44%, 61%, and 80%, respectively. Tumor to background ratios (T/B) in benign lesions (2.04 +/- 0.27) were significantly lower than in malignant lesions (7.4 +/- 0.99). F18-FDG Co-PET is of clinical value when assessing suspicious malignant adnexal masses. False-negative F18-FDG results might arise from borderline disease. Moderate F18-FDG uptake in leiomyomas can result false-positive, but T/B ratios may be helpful in such cases.

  1. Fluorometric determination of Vibrio parahaemolyticus using an F0F1-ATPase-based aptamer and labeled chromatophores.

    PubMed

    Duan, Nuo; Wu, Shijia; Zhang, Huiling; Zou, Ying; Wang, Zhouping

    2018-05-18

    An F 0 F 1 -ATPase-based aptasensor is described for the fluorometric determination of Vibrio parahaemolyticus. Chromatophores containing F 0 F 1 -ATPases were first prepared from Rhodospirillum rubrum cells. Then, an aptamer-functionalized chromatophore acts as the capture probe, and a chromatophore labeled with the pH probe fluorescein acts as the signalling probe. In the presence of V. parahaemolyticus, the rotation rate of F 0 F 1 -ATPase is decreased due to the formation of the aptamer-chromatophore complex. This leads to a retarded proton flux out of the chromatophores. As a result, the pH value inside the chromatophores is reduced, and the fluorescence of the pH probe F1300 is accordingly decreased. The relative fluorescence varies linearly over the 15 to 1.5 × 10 6  cfu·mL -1 Vibrio parahaemolyticus concentration range, and the limit of detection is 15 cfu·mL -1 . The method was applied to analyze artificially contaminated salmon samples where it showed excellent perfomance. Graphical abstract In this assay, aptamer functionalized chromatophores act as a capture probe, and the fluoresce in labeled chromatophores as signalling probe. The formation of aptamer-chromatophore complex leads to a retarded proton flux out of the chromatophores. As a result, the pH value inside the chromatophores is reduced, and fluorescence intensity is accordingly decreased.

  2. Metabolic liver function measured in vivo by dynamic (18)F-FDGal PET/CT without arterial blood sampling.

    PubMed

    Horsager, Jacob; Munk, Ole Lajord; Sørensen, Michael

    2015-01-01

    Metabolic liver function can be measured by dynamic PET/CT with the radio-labelled galactose-analogue 2-[(18)F]fluoro-2-deoxy-D-galactose ((18)F-FDGal) in terms of hepatic systemic clearance of (18)F-FDGal (K, ml blood/ml liver tissue/min). The method requires arterial blood sampling from a radial artery (arterial input function), and the aim of this study was to develop a method for extracting an image-derived, non-invasive input function from a volume of interest (VOI). Dynamic (18)F-FDGal PET/CT data from 16 subjects without liver disease (healthy subjects) and 16 patients with liver cirrhosis were included in the study. Five different input VOIs were tested: four in the abdominal aorta and one in the left ventricle of the heart. Arterial input function from manual blood sampling was available for all subjects. K*-values were calculated using time-activity curves (TACs) from each VOI as input and compared to the K-value calculated using arterial blood samples as input. Each input VOI was tested on PET data reconstructed with and without resolution modelling. All five image-derived input VOIs yielded K*-values that correlated significantly with K calculated using arterial blood samples. Furthermore, TACs from two different VOIs yielded K*-values that did not statistically deviate from K calculated using arterial blood samples. A semicircle drawn in the posterior part of the abdominal aorta was the only VOI that was successful for both healthy subjects and patients as well as for PET data reconstructed with and without resolution modelling. Metabolic liver function using (18)F-FDGal PET/CT can be measured without arterial blood samples by using input data from a semicircle VOI drawn in the posterior part of the abdominal aorta.

  3. Utility of 18F-fluoro-deoxyglucose emission tomography/computed tomography fusion imaging (18F-FDG PET/CT) in combination with ultrasonography for axillary staging in primary breast cancer.

    PubMed

    Ueda, Shigeto; Tsuda, Hitoshi; Asakawa, Hideki; Omata, Jiro; Fukatsu, Kazuhiko; Kondo, Nobuo; Kondo, Tadaharu; Hama, Yukihiro; Tamura, Katsumi; Ishida, Jiro; Abe, Yoshiyuki; Mochizuki, Hidetaka

    2008-06-09

    Accurate evaluation of axillary lymph node (ALN) involvement is mandatory before treatment of primary breast cancer. The aim of this study is to compare preoperative diagnostic accuracy between positron emission tomography/computed tomography with 18F-fluorodeoxyglucose (18F-FDG PET/CT) and axillary ultrasonography (AUS) for detecting ALN metastasis in patients having operable breast cancer, and to assess the clinical management of axillary 18F-FDG PET/CT for therapeutic indication of sentinel node biopsy (SNB) and preoperative systemic chemotherapy (PSC). One hundred eighty-three patients with primary operable breast cancer were recruited. All patients underwent 18F-FDG PET/CT and AUS followed by SNB and/or ALN dissection (ALND). Using 18F-FDG PET/CT, we studied both a visual assessment of 18F-FDG uptake and standardized uptake value (SUV) for axillary staging. In a visual assessment of 18F-FDG PET/CT, the diagnostic accuracy of ALN metastasis was 83% with 58% in sensitivity and 95% in specificity, and when cut-off point of SUV was set at 1.8, sensitivity, specificity, and accuracy were 36, 100, and 79%, respectively. On the other hand, the diagnostic accuracy of AUS was 85% with 54% in sensitivity and 99% in specificity. By the combination of 18F-FDG PET/CT and AUS to the axilla, the sensitivity, specificity, and accuracy were 64, 94, and 85%, respectively. If either 18F-FDG PET uptake or AUS was positive in allixa, the probability of axillary metastasis was high; 50% (6 of 12) in 18F-FDG PET uptake only, 80% (4 of 5) in AUS positive only, and 100% (28 of 28) in dual positive. By the combination of AUS and 18F-FDG PET/CT, candidates of SNB were more appropriately selected. The axillary 18F-FDG uptake was correlated with the maximum size and nuclear grade of metastatic foci (p = 0.006 and p = 0.03). The diagnostic accuracy of 18F-FDG PET/CT was shown to be nearly equal to ultrasound, and considering their limited sensitivities, the high radiation exposure by 18F

  4. Integrated whole-body PET/MR imaging with 18F-FDG, 18F-FDOPA, and 18F-fluorodopamine in paragangliomas, in comparison to PET/CT: NIH first clinical experience with a single-injection, dual-modality imaging protocol

    PubMed Central

    Blanchet, Elise M.; Millo, Corina; Martucci, Victoria; Maass-Moreno, Roberto; Bluemke, David A.; Pacak, Karel

    2017-01-01

    Purpose Paragangliomas (PGLs) are tumors that can metastasize and recur; therefore, lifelong imaging follow-up is required. Hybrid positron emission tomography (PET)/computed tomography (/CT) is an essential tool to image PGLs. Novel hybrid PET/magnetic resonance (/MR) scanners are currently being studied in clinical oncology. We studied the feasibility of simultaneous whole-body PET/MR imaging to evaluate patients with PGLs. Methods Fifty-three PGLs or PGL-related lesions from eight patients were evaluated. All patients underwent a single-injection, dual-modality imaging protocol consisting of a PET/CT and subsequent PET/MR scan. Four patients were evaluated with 18F-fluorodeoxyglucose (18F-FDG), two with 18F-fluorodihydroxyphenylalanine (18F-FDOPA), and two with 18F-fluorodopamine (18F-FDA). PET/MR data were acquired using a hybrid whole-body 3-Tesla integrated PET/MR scanner. PET and MR data (DIXON images for attenuation correction and T2-weighted sequences for anatomic allocation) were acquired simultaneously. Imaging workflow and imaging times were documented. PET/MR and PET/CT data were visually assessed (blindly) in regards to image quality, lesion detection, and anatomic allocation and delineation of the PET findings. Results With hybrid PET/MR, we obtained high quality images in an acceptable acquisition time (median: 31 min, range: 25–40 min) with good patient compliance. A total of 53 lesions, located in the head-and-neck area (6), mediastinum (2), abdomen and pelvis (13), lungs (2), liver (4), and bone (26) were evaluated. 51 lesions were detected with PET/MR and confirmed by PET/CT. Two bone lesions (L4 body (8 mm) and sacrum (6 mm)) were not detectable on an 18F-FDA scan PET/MR, likely due to washout of the 18F-FDA. Co-registered MR tended to be superior to co-registered CT for head-and-neck, abdomen, pelvis, and liver lesions for anatomic allocation and delineation. Conclusions Clinical PGL evaluation with hybrid PET/MR is feasible with high image

  5. Binding of 2-[18F]fluoro-CP-118,954 to mouse acetylcholinesterase: microPET and ex vivo Cerenkov luminescence imaging studies.

    PubMed

    Kim, Dong Hyun; Choe, Yearn Seong; Choi, Joon Young; Lee, Kyung-Han; Kim, Byung-Tae

    2011-05-01

    Acetylcholinesterase (AChE) has been an important cholinergic factor for the diagnosis of Alzheimer's disease (AD), because of reduced AChE activity in the postmortem brains of AD patients. We previously developed 5,7-dihydro-3-(2-(1-(2-[(18)F]fluorobenzyl)-4-piperidinyl)ethyl)-6H-pyrrolo(3,2,f)-1,2-benzisoxazol-6-one (2-[(18)F]fluoro-CP-118,954) for in vivo studies of AChE in mice. In the present study, we automated the synthesis of 2-[(18)F]fluoro-CP-118,954 for the routine use and evaluated the radioligand by microPET and ex vivo Cerenkov luminescence imaging of mouse AChE. 4-[(18)F]Fluoro-donepezil, another AChE inhibitor, was used for comparison. Automated syntheses of 2-[(18)F]fluoro-CP-118,954 and 4-[(18)F]fluoro-donepezil resulted in high radiochemical yields (25-33% and 30-40%) and high specific activity (27.1-35.4 and 29.7-37.3 GBq/μmol). Brain microPET images of two ICR mice injected with 2-[(18)F]fluoro-CP-118,954 demonstrated high uptake in the striatum (ROI analysis: 5.1 %ID/g for the first 30 min and 4.1 %ID/g for another 30 min), and a blocking study with injection of CP-118,954 into one of the mice at 30 min after radioligand injection led to complete blocking of radioligand uptake in the striatum (ROI analysis: 1.9 %ID/g), whereas (18)F-labeled donepezil did not show specific uptake in the striatum. In another set of experiments, the brain tissues (striatum, parietal cortex, frontal cortex and cerebellum) were excised after brain microPET/CT imaging of mouse injected with 2-[(18)F]fluoro-CP-118,954, and a high striatal uptake was also detected in ex vivo optical and microPET images (ROI analysis: 1.4 %ID/g) and in γ-counting data (2.1 %ID/g at 50 min post-injection) of the brain tissues. Taken together, these results demonstrated that 2-[(18)F]fluoro-CP-118,954 specifically binds to AChE in mouse brains. Copyright © 2011 Elsevier Inc. All rights reserved.

  6. Preclinical evaluation of 18F-ML-10 to determine timing of apoptotic response to chemotherapy in solid tumors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Demirci, Emre; Ahmed, Rafay; Ocak, Meltem

    Here, we investigated 2-(5-fluoro-pentyl)-2-methyl-malonic acid ( 18F-ML-10) positron emission tomography (PET) imaging of apoptosis posttherapy to determine optimal timing for predicting chemotherapy response in a mouse head/neck xenograft cancer model. BALB/c nude mice (4-8 weeks old) were implanted with UM-SCC-22B tumors. The treatment group received 2 doses of doxorubicin (10 mg/kg, days 0, 2). Small animal 18F-ML-10 PET/computed tomography was performed before and on days 1, 3, and 7 postchemotherapy. Using regions of interest around tumors, 18F-ML-10 uptake change was measured as %ID/g and uptake relative to liver. Terminal Uridine Nick-End Labeling (TUNEL) immunohistochemistry assay was performed using tumor samplesmore » of baseline and on days 1, 3, and 7 posttreatment. As a result, treated mice demonstrated increased 18F-ML-10 uptake compared to baseline and controls, and 10 of 13 mice showed tumor volume decreases. All control mice showed tumor volume increases. Tumor-to-liver (T/L) ratios from the control group mice did not show significant change from baseline ( P > .05); however, T/L ratios of the treatment group showed significant 18F-ML-10 uptake differences from baseline compared to days 3 and 7 posttreatment ( P < .05), but no significant difference at 1 day posttreatment. In conclusion, 2-(5-Fluoro-pentyl)-2-methyl-malonic acid PET imaging has the potential for early assessment of treatment-induced apoptosis. Timing and image analysis strategies may require optimization, depending on the type of tumor and cancer treatment.« less

  7. Preclinical evaluation of 18F-ML-10 to determine timing of apoptotic response to chemotherapy in solid tumors

    DOE PAGES

    Demirci, Emre; Ahmed, Rafay; Ocak, Meltem; ...

    2017-01-10

    Here, we investigated 2-(5-fluoro-pentyl)-2-methyl-malonic acid ( 18F-ML-10) positron emission tomography (PET) imaging of apoptosis posttherapy to determine optimal timing for predicting chemotherapy response in a mouse head/neck xenograft cancer model. BALB/c nude mice (4-8 weeks old) were implanted with UM-SCC-22B tumors. The treatment group received 2 doses of doxorubicin (10 mg/kg, days 0, 2). Small animal 18F-ML-10 PET/computed tomography was performed before and on days 1, 3, and 7 postchemotherapy. Using regions of interest around tumors, 18F-ML-10 uptake change was measured as %ID/g and uptake relative to liver. Terminal Uridine Nick-End Labeling (TUNEL) immunohistochemistry assay was performed using tumor samplesmore » of baseline and on days 1, 3, and 7 posttreatment. As a result, treated mice demonstrated increased 18F-ML-10 uptake compared to baseline and controls, and 10 of 13 mice showed tumor volume decreases. All control mice showed tumor volume increases. Tumor-to-liver (T/L) ratios from the control group mice did not show significant change from baseline ( P > .05); however, T/L ratios of the treatment group showed significant 18F-ML-10 uptake differences from baseline compared to days 3 and 7 posttreatment ( P < .05), but no significant difference at 1 day posttreatment. In conclusion, 2-(5-Fluoro-pentyl)-2-methyl-malonic acid PET imaging has the potential for early assessment of treatment-induced apoptosis. Timing and image analysis strategies may require optimization, depending on the type of tumor and cancer treatment.« less

  8. Evaluation of the Outcome of Lung Nodules Missed on 18F-FDG PET/MRI Compared with 18F-FDG PET/CT in Patients with Known Malignancies.

    PubMed

    Sawicki, Lino M; Grueneisen, Johannes; Buchbender, Christian; Schaarschmidt, Benedikt M; Gomez, Benedikt; Ruhlmann, Verena; Umutlu, Lale; Antoch, Gerald; Heusch, Philipp

    2016-01-01

    The lower detection rate of (18)F-FDG PET/MRI than (18)F-FDG PET/CT regarding small lung nodules should be considered in the staging of malignant tumors. The purpose of this study was to evaluate the outcome of these small lung nodules missed by (18)F-FDG PET/MRI. Fifty-one oncologic patients (mean age ± SD, 56.6 ± 14.0 y; 29 women, 22 men; tumor stages, I [n = 7], II [n = 7], III [n = 9], IV [n = 28]) who underwent (18)F-FDG PET/CT and subsequent (18)F-FDG PET/MRI on the same day were retrospectively enrolled. Images were analyzed by 2 interpreters in random order and separate sessions with a minimum of 4 wk apart. A maximum of 10 lung nodules was identified for each patient on baseline imaging. The presence, size, and presence of focal tracer uptake was noted for each lung nodule detected on (18)F-FDG PET/CT and (18)F-FDG PET/MRI using a postcontrast T1-weighted 3-dimensional gradient echo volume-interpolated breath-hold examination sequence with fat suppression as morphologic dataset. Follow-up CT or (18)F-FDG PET/CT (mean time to follow-up, 11 mo; range, 3-35 mo) was used as a reference standard to define each missed nodule as benign or malignant based on changes in size and potential new tracer uptake. Nodule-to-nodule comparison between baseline and follow-up was performed using descriptive statistics. Out of 134 lung nodules found on (18)F-FDG PET/CT, (18)F-FDG PET/MRI detected 92 nodules. Accordingly, 42 lung nodules (average size ± SD, 3.9 ± 1.3 mm; range, 2-7 mm) were missed by (18)F-FDG PET/MRI. None of the missed lung nodules presented with focal tracer uptake on baseline imaging or follow-up (18)F-FDG PET/CT. Thirty-three out of 42 missed lung nodules (78.6%) in 26 patients were rated benign, whereas 9 nodules (21.4%) in 4 patients were rated malignant. As a result, 1 patient required upstaging from tumor stage I to IV. Although most small lung nodules missed on (18)F-FDG PET/MRI were found to be benign, there was a relevant number of undetected

  9. Cranberry extract inhibits in vitro adhesion of F4 and F18+Escherichia coli to pig intestinal epithelium and reduces in vivo excretion of pigs orally challenged with F18+ verotoxigenic E. coli.

    PubMed

    Coddens, Annelies; Loos, Michaela; Vanrompay, Daisy; Remon, Jean Paul; Cox, Eric

    2017-04-01

    F4 + E. coli and F18 + E. coli infections are an important threat for pig industry worldwide. Antibiotics are commonly used to treat infected piglets, but the emerging development of resistance against antibiotics raises major concerns. Hence, alternative therapies to prevent pigs from F4 + E. coli and F18 + E. coli infections need to be developed. Since cranberry previously showed anti-adhesive activity against uropathogenic E. coli, we aimed to investigate whether cranberry extract could also inhibit binding of F4 + E. coli and F18 + E. coli to pig intestinal epithelium. Using the in vitro villus adhesion assay, we found that low concentrations of cranberry extract (20μg or 100μg/ml) have strong inhibitory activity on F4 + E. coli (75.3%, S.D.=9.31 or 95.8%, S.D.=2.56, respectively) and F18 + E. coli adherence (100% inhibition). This effect was not due to antimicrobial activity. Moreover, cranberry extract (10mg or 100mg) could also abolish in vivo binding of F4 and F18 fimbriae to the pig intestinal epithelium in ligated loop experiments. Finally, two challenge experiments with F18 + E. coli were performed to address the efficacy of in-feed or water supplemented cranberry extract. No effect could be observed in piglets that received cranberry extract only in feed (1g/kg or 10g/kg). However, supplementation of feed (10g/kg) and drinking water (1g/L) significantly decreased excretion and diarrhea. The decreased infection resulted in a decreased serum antibody response indicating reduced exposure to F18 + E. coli. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Dose calibrator linearity test: 99mTc versus 18F radioisotopes*

    PubMed Central

    Willegaignon, José; Sapienza, Marcelo Tatit; Coura-Filho, George Barberio; Garcez, Alexandre Teles; Alves, Carlos Eduardo Gonzalez Ribeiro; Cardona, Marissa Anabel Rivera; Gutterres, Ricardo Fraga; Buchpiguel, Carlos Alberto

    2015-01-01

    Objective The present study was aimed at evaluating the viability of replacing 18F with 99mTc in dose calibrator linearity testing. Materials and Methods The test was performed with sources of 99mTc (62 GBq) and 18F (12 GBq) whose activities were measured up to values lower than 1 MBq. Ratios and deviations between experimental and theoretical 99mTc and 18F sources activities were calculated and subsequently compared. Results Mean deviations between experimental and theoretical 99mTc and 18F sources activities were 0.56 (± 1.79)% and 0.92 (± 1.19)%, respectively. The mean ratio between activities indicated by the device for the 99mTc source as measured with the equipment pre-calibrated to measure 99mTc and 18F was 3.42 (± 0.06), and for the 18F source this ratio was 3.39 (± 0.05), values considered constant over the measurement time. Conclusion The results of the linearity test using 99mTc were compatible with those obtained with the 18F source, indicating the viability of utilizing both radioisotopes in dose calibrator linearity testing. Such information in association with the high potential of radiation exposure and costs involved in 18F acquisition suggest 99mTc as the element of choice to perform dose calibrator linearity tests in centers that use 18F, without any detriment to the procedure as well as to the quality of the nuclear medicine service. PMID:25798005

  11. 18F-FDOPA PET/CT imaging of MAX-related pheochromocytoma.

    PubMed

    Taïeb, David; Jha, Abhishek; Guerin, Carole; Pang, Ying; Adams, Karen T; Chen, Clara C; Romanet, Pauline; Roche, Philippe; Essamet, Wassim; Ling, Alexander; Quezado, Martha M; Castinetti, Frédéric; Sebag, Fréderic; Pacak, Karel

    2018-03-08

    MYC associated factor X (MAX) has been recently described as a new susceptibility pheochromocytoma (PHEO) gene with a total of approximately 40 reported cases. At present, no study has specifically described the functional imaging phenotype of MAX-related PHEO. The objective of this study was to present our experience with contrast-enhanced CT and 18F-FDOPA PET/CT imaging in 6 consecutive patients (4 at initial diagnosis and 2 at follow-up evaluation) with rare but clinically important MAX-related PHEOs. In 5 patients, 18F-FDOPA was also compared to other radiopharmaceuticals. Patients had 5 different mutations in the MAX gene that caused disruption of Max/Myc interaction and/or abolished interaction with DNA based on in-silico analyses. All but one patient developed bilateral PHEOs during their lifetime. In all cases, 18F-FDOPA PET/CT accurately visualized PHEOs that were often multiple within the same gland or bilateral and detected more adrenal and extradrenal lesions than CT (per lesion sensitivity 90.5% vs 52.4% for CT/MRI). The 2 missed PHEO on 18F-FDOPA PET/CT were <1cm, corresponding to nodular adrenomedullary hyperplasia. 68Ga-DOTATATE PET/CT detected fewer lesions than 18F-FDOPA PET/CT in 1/3 patients and 18F-FDG PET/CT was only faintly positive in 2/4 patients with underestimation of extraadrenal lesions in 1 patient. MAX-related PHEO exihibit a marked 18F-FDOPA uptake, a finding that illustrates the common well-differentiated chromaffin pattern of PHEO associated with activation of kinase signaling pathways. 18F-FDOPA PET/CT should be considered as the first-line functional imaging modality for diagnostic or follow-up evaluation in these patients.

  12. Procedures for the GMP-Compliant Production and Quality Control of [18F]PSMA-1007: A Next Generation Radiofluorinated Tracer for the Detection of Prostate Cancer

    PubMed Central

    Cardinale, Jens; Martin, René; Remde, Yvonne; Schäfer, Martin; Hienzsch, Antje; Hübner, Sandra; Zerges, Anna-Maria; Marx, Heike; Hesse, Ronny; Weber, Klaus; Smits, Rene; Hoepping, Alexander; Müller, Marco; Neels, Oliver C.; Kopka, Klaus

    2017-01-01

    Radiolabeled tracers targeting the prostate-specific membrane antigen (PSMA) have become important radiopharmaceuticals for the PET-imaging of prostate cancer. In this connection, we recently developed the fluorine-18-labelled PSMA-ligand [18F]PSMA-1007 as the next generation radiofluorinated Glu-ureido PSMA inhibitor after [18F]DCFPyL and [18F]DCFBC. Since radiosynthesis so far has been suffering from rather poor yields, novel procedures for the automated radiosyntheses of [18F]PSMA-1007 have been developed. We herein report on both the two-step and the novel one-step procedures, which have been performed on different commonly-used radiosynthesisers. Using the novel one-step procedure, the [18F]PSMA-1007 was produced in good radiochemical yields ranging from 25 to 80% and synthesis times of less than 55 min. Furthermore, upscaling to product activities up to 50 GBq per batch was successfully conducted. All batches passed quality control according to European Pharmacopoeia standards. Therefore, we were able to disclose a new, simple and, at the same time, high yielding production pathway for the next generation PSMA radioligand [18F]PSMA-1007. Actually, it turned out that the radiosynthesis is as easily realised as the well-known [18F]FDG synthesis and, thus, transferable to all currently-available radiosynthesisers. Using the new procedures, the clinical daily routine can be sustainably supported in-house even in larger hospitals by a single production batch. PMID:28953234

  13. Measurement of 17F(d ,n )18Ne and the impact on the 17F(p ,γ )18Ne reaction rate for astrophysics

    NASA Astrophysics Data System (ADS)

    Kuvin, S. A.; Belarge, J.; Baby, L. T.; Baker, J.; Wiedenhöver, I.; Höflich, P.; Volya, A.; Blackmon, J. C.; Deibel, C. M.; Gardiner, H. E.; Lai, J.; Linhardt, L. E.; Macon, K. T.; Rasco, B. C.; Quails, N.; Colbert, K.; Gay, D. L.; Keeley, N.

    2017-10-01

    Background: The 17F(p ,γ )18Ne reaction is part of the astrophysical "hot CNO" cycles that are important in astrophysical environments like novas. Its thermal reaction rate is low owing to the relatively high energy of the resonances and therefore is dominated by direct, nonresonant capture in stellar environments at temperatures below 0.4 GK. Purpose: An experimental method is established to extract the proton strength to bound and unbound states in experiments with radioactive ion beams and to determine the parameters of direct and resonant capture in the 17F(p ,γ )18Ne reaction. Method: The 17F(d ,n )18Ne reaction is measured in inverse kinematics using a beam of the short-lived isotope 17F and a compact setup of neutron, proton, γ -ray, and heavy-ion detectors called resoneut. Results: The spectroscopic factors for the lowest l =0 proton resonances at Ec .m .=0.60 and 1.17 MeV are determined, yielding results consistent within 1.4 σ of previous proton elastic-scattering measurements. The asymptotic normalization coefficients of the bound 21+ and 22+ states in 18Ne are determined and the resulting direct-capture reaction rates are extracted. Conclusions: The direct-capture component of the 17F(p ,γ )18Ne reaction is determined for the first time from experimental data on 18Ne.

  14. Optimizing Maintenance Manpower for USMC F/A-18 Squadrons

    DTIC Science & Technology

    2016-06-01

    experience level, with the requirement of keeping a standard number of aircraft operationally ready. MVP results show areas of deficit, either manpower ...MAINTENANCE MANPOWER FOR USMC F/A-18 SQUADRONS by Kevin J. Goodwin June 2016 Thesis Co-Advisors: W. Matthew Carlyle Robert F. Dell Second...REPORT TYPE AND DATES COVERED Master’s thesis 4. TITLE AND SUBTITLE OPTIMIZING MAINTENANCE MANPOWER FOR USMC F/A-18 SQUADRONS 5. FUNDING NUMBERS 6

  15. Automated production at the curie level of no-carrier-added 6-[(18)F]fluoro-L-dopa and 2-[(18)F]fluoro-L-tyrosine on a FASTlab synthesizer.

    PubMed

    Lemaire, C; Libert, L; Franci, X; Genon, J-L; Kuci, S; Giacomelli, F; Luxen, A

    2015-06-15

    An efficient, fully automated, enantioselective multi-step synthesis of no-carrier-added (nca) 6-[(18)F]fluoro-L-dopa ([(18)F]FDOPA) and 2-[(18)F]fluoro-L-tyrosine ([(18)F]FTYR) on a GE FASTlab synthesizer in conjunction with an additional high- performance liquid chromatography (HPLC) purification has been developed. A PTC (phase-transfer catalyst) strategy was used to synthesize these two important radiopharmaceuticals. According to recent chemistry improvements, automation of the whole process was implemented in a commercially available GE FASTlab module, with slight hardware modification using single use cassettes and stand-alone HPLC. [(18)F]FDOPA and [(18)F]FTYR were produced in 36.3 ± 3.0% (n = 8) and 50.5 ± 2.7% (n = 10) FASTlab radiochemical yield (decay corrected). The automated radiosynthesis on the FASTlab module requires about 52 min. Total synthesis time including HPLC purification and formulation was about 62 min. Enantiomeric excesses for these two aromatic amino acids were always >95%, and the specific activity of was >740 GBq/µmol. This automated synthesis provides high amount of [(18)F]FDOPA and [(18)F]FTYR (>37 GBq end of synthesis (EOS)). The process, fully adaptable for reliable production across multiple PET sites, could be readily implemented into a clinical good manufacturing process (GMP) environment. Copyright © 2015 John Wiley & Sons, Ltd.

  16. Comparative assessment of 6-[18 F]fluoro-L-m-tyrosine and 6-[18 F]fluoro-L-dopa to evaluate dopaminergic presynaptic integrity in a Parkinson's disease rat model.

    PubMed

    Becker, Guillaume; Bahri, Mohamed Ali; Michel, Anne; Hustadt, Fabian; Garraux, Gaëtan; Luxen, André; Lemaire, Christian; Plenevaux, Alain

    2017-05-01

    Because of the progressive loss of nigro-striatal dopaminergic terminals in Parkinson's disease (PD), in vivo quantitative imaging of dopamine (DA) containing neurons in animal models of PD is of critical importance in the preclinical evaluation of highly awaited disease-modifying therapies. Among existing methods, the high sensitivity of positron emission tomography (PET) is attractive to achieve that goal. The aim of this study was to perform a quantitative comparison of brain images obtained in 6-hydroxydopamine (6-OHDA) lesioned rats using two dopaminergic PET radiotracers, namely [ 18 F]fluoro-3,4-dihydroxyphenyl-L-alanine ([ 18 F]FDOPA) and 6-[ 18 F]fluoro-L-m-tyrosine ([ 18 F]FMT). Because the imaging signal is theoretically less contaminated by metabolites, we hypothesized that the latter would show stronger relationship with behavioural and post-mortem measures of striatal dopaminergic deficiency. We used a within-subject design to measure striatal [ 18 F]FMT and [ 18 F]FDOPA uptake in eight partially lesioned, eight fully lesioned and ten sham-treated rats. Animals were pretreated with an L-aromatic amino acid decarboxylase inhibitor. A catechol-O-methyl transferase inhibitor was also given before [ 18 F]FDOPA PET. Quantitative estimates of striatal uptake were computed using conventional graphical Patlak method. Striatal dopaminergic deficiencies were measured with apomorphine-induced rotations and post-mortem striatal DA content. We observed a strong relationship between [ 18 F]FMT and [ 18 F]FDOPA estimates of decreased uptake in the denervated striatum using the tissue-derived uptake rate constant K c . However, only [ 18 F]FMT K c succeeded to discriminate between the partial and the full 6-OHDA lesion and correlated well with the post-mortem striatal DA content. This study indicates that the [ 18 F]FMT could be more sensitive, with respect of [ 18 F]FDOPA, to investigate DA terminals loss in 6-OHDA rats, and open the way to in vivo L

  17. 18F-FDG positron emission tomography/computed tomography in infective endocarditis.

    PubMed

    Salomäki, Soile Pauliina; Saraste, Antti; Kemppainen, Jukka; Bax, Jeroen J; Knuuti, Juhani; Nuutila, Pirjo; Seppänen, Marko; Roivainen, Anne; Airaksinen, Juhani; Pirilä, Laura; Oksi, Jarmo; Hohenthal, Ulla

    2017-02-01

    The diagnosis of infective endocarditis (IE), especially the diagnosis of prosthetic valve endocarditis (PVE) is challenging since echocardiographic findings are often scarce in the early phase of the disease. We studied the use of 2-[ 18 F]fluoro-2-deoxy-D-glucose ( 18 F-FDG) positron emission tomography/computed tomography (PET/CT) in IE. Sixteen patients with suspected PVE and 7 patients with NVE underwent visual evaluation of 18 F-FDG-PET/CT. 18 F-FDG uptake was measured also semiquantitatively as maximum standardized uptake value (SUV max ) and target-to-background ratio (TBR). The modified Duke criteria were used as a reference. There was strong, focal 18 F-FDG uptake in the area of the affected valve in all 6 cases of definite PVE, in 3 of 5 possible PVE cases, and in 2 of 5 rejected cases. In all patients with definite PVE, SUV max of the affected valve was higher than 4 and TBR higher than 1.8. In contrast to PVE, only 1 of 7 patients with NVE had uptake of 18 F-FDG by PET/CT in the valve area. Embolic infectious foci were detected in 58% of the patients with definite IE. 18 F-FDG-PET/CT appears to be a sensitive method for the detection of paravalvular infection associated with PVE. Instead, the sensitivity of PET/CT is limited in NVE.

  18. Two years of experience with the [ 18F]FDG production module

    NASA Astrophysics Data System (ADS)

    Kim, Sang Wook; Hur, Min Goo; Chai, Jong-Seo; Park, Jeong Hoon; Yu, Kook Hyun; Jeong, Cheol Ki; Lee, Goung Jin; Min, Young Don; Yang, Seung Dae

    2007-08-01

    Chemistry module for a conventional [18F]FDG production by using tetrabutylammonium bicarbonate (TBA) and an acidic hydrolysis has been manufactured and evaluated. In this experiment, 75 mM (pH 7.5-7.8) of TBA solution and a ca. 2-curies order of [18F]-fluoride have been used for the evaluation. The commercial acidic purification cartridge was purchased from GE or UKE. The operation system (OS) was programmed with Lab-View which was selected because of its easy customization of the OS. Small sized solenoid valves (Burkert; type 6124) were selected to reduce the module dimensions (W 350 × D 270 × H 250). The total time for the synthesis of [18F]FDG was 30 ± 3 min. The production yield of [18F]FDG was 60 ± 2% on an average at EOS, with the decay uncorrected. This experimental data show that the traditional chemistry module can provide a good [18F]FDG production yield by optimizing the operational conditions. The radiochemical purity, radionuclidic purity, acidity, residual solvent, osmolality and endotoxin were determined to assess the quality of [18F]FDG. The examined contents for the quality control of [18F]FDG were found to be suitable for a clinical application.

  19. Development of novel approach to diagnostic imaging of lung cancer with 18F-Nifene PET/CT using A/J mice treated with NNK

    PubMed Central

    Galitovskiy, V; Kuruvilla, SA; Sevriokov, E; Corches, A; Pan, ML; Kalantari-Dehaghi, M; Chernyavsky, AI; Mukherjee, J; Grando, SA

    2017-01-01

    Development of novel methods of early diagnosis of lung cancer is one of the major tasks of contemporary clinical and experimental oncology. In this study, we utilized the tobacco nitrosamine 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK)-induced lung cancer in A/J mice as an animal model for development of a new imaging technique for early diagnosis of lung cancer. Lung cancer cells in A/J mice overexpress nicotinic acetylcholine receptors. Longitudinal CT scans were carried out over a period of 8 months after NNK treatment, followed by PET/CT scans with 18F-Nifene that binds to α4-made nicotinic receptors with high affinity. PET/CT scans of lungs were also obtained ex vivo. CT revealed the presence of lung nodules in 8-month NNK-treated mice, while control mice had no tumors. Imaging of live animals prior to necropsy allowed correlation of results of tumor load via PET/CT and histopathological findings. Significant amount of 18F-Nifene was seen in the lungs of NNK-treated mice, whereas lungs of control mice showed only minor uptake of 18F-Nifene. Quantitative analysis of the extent and amount of 18F-Nifene binding in lung in vivo and ex vivo demonstrated a higher tumor/nontumor ratio due to selective labeling of tumor nodules expressing abundant α4 nicotinic receptor subunits. For comparison, we performed PET/CT studies with 18F-FDG, which is used for the imaging diagnosis of lung cancer. The tumor/nontumor ratios for 18F-FDG were lower than for 18F-Nifene. Thus, we have developed a novel diagnostic imaging approach to early diagnosis of lung cancer using 18F-Nifene PET/CT. This technique allows quantitative assessment of lung tumors in live mice, which is critical for establishing tumor size and location, and also has salient clinical implications. PMID:28553544

  20. Water-tunnel study results of a TF/A-18 and F/A-18 canopy flow visualization

    NASA Technical Reports Server (NTRS)

    Johnson, Steven A.; Fisher, David F.

    1990-01-01

    A water tunnel study examining the influence of canopy shape on canopy and leading edge extension flow patterns was initiated. The F/A-18 single-place canopy model and the TF/A-18 two place canopy model were the study subjects. Plan view and side view photographs showing the flow patterns created by injected colored dye are presented for 0 deg and 5 deg sideslip angles. Photographs taken at angle of attack and sideslip conditions correspond to test departure points found in flight test. Flight experience has shown that the TF/A-18 airplane departs in regions where the F/A-18 airplane is departure-resistant. The study results provide insight into the differences in flow patterns which may influence the resulting aerodynamics of the TF/A-18 and F/A-18 aircraft. It was found that at 0 deg sideslip, the TF/A-18 model has more downward flow on the sides of the canopy than the F/A-18 model. This could be indicative of flow from the leading edge extension (LEX) vortexes impinging on the sides of the wider TF/A-18 canopy. In addition, the TF/A-18 model has larger areas of asymmetric separated and unsteady flow on the LEXs and fuselage, possibly indicating a lateral and directional destabilizing effect at the conditions studied.

  1. Evaluation of Fluorine-18-Labeled α1(I)-N-Telopeptide Analogs as Substrate-Based Radiotracers for PET Imaging of Melanoma-Associated Lysyl Oxidase.

    PubMed

    Kuchar, Manuela; Neuber, Christin; Belter, Birgit; Bergmann, Ralf; Lenk, Jens; Wodtke, Robert; Kniess, Torsten; Steinbach, Jörg; Pietzsch, Jens; Löser, Reik

    2018-01-01

    Accumulating evidence suggests an unequivocal role of lysyl oxidases as key players of tumor progression and metastasis, which renders this enzyme family highly attractive for targeted non-invasive functional imaging of tumors. Considering their function in matrix remodeling, malignant melanoma appears as particularly interesting neoplasia in this respect. For the development of radiotracers that enable PET imaging of the melanoma-associated lysyl oxidase activity, substrates derived from the type I collagen α1 N-telopeptide were labeled with fluorine-18 using N -succinimidyl 4-[ 18 F]fluorobenzoate ([ 18 F]SFB) as prosthetic reagent. With regards to potential crosslinking to tumor-associated collagen in vivo , their interaction with triple-helical type I collagen was studied by SPR. A mouse model of human melanoma was established on the basis of the A375 cell line, for which the expression of the oncologically relevant lysyl oxidase isoforms LOX and LOXL2 was demonstrated in Western blot and immunohistochemical experiments. The radiopharmacological profiles of the peptidic radiotracers were evaluated in normal rats and A375 melanoma-bearing mice by ex vivo metabolite analysis, whole-body biodistribution studies and dynamic PET imaging. Out of three 18 F-labeled telopeptide analogs, the one with the most favorable substrate properties has shown favorable tumor uptake and tumor-to-muscle ratio. Lysyl oxidase-mediated tumor uptake was proven by pharmacological inhibition using β-aminopropionitrile and by employing negative-control analogs of impeded or abolished targeting capability. The latter were obtained by substituting the lysine residue by ornithine and norleucine, respectively. Comparing the tumor uptake of the lysine-containing peptide with that of the non-functional analogs indicate the feasibility of lysyl oxidase imaging in melanoma using substrate-based radiotracers.

  2. Evaluation of Fluorine-18-Labeled α1(I)-N-Telopeptide Analogs as Substrate-Based Radiotracers for PET Imaging of Melanoma-Associated Lysyl Oxidase

    PubMed Central

    Kuchar, Manuela; Neuber, Christin; Belter, Birgit; Bergmann, Ralf; Lenk, Jens; Wodtke, Robert; Kniess, Torsten; Steinbach, Jörg; Pietzsch, Jens; Löser, Reik

    2018-01-01

    Accumulating evidence suggests an unequivocal role of lysyl oxidases as key players of tumor progression and metastasis, which renders this enzyme family highly attractive for targeted non-invasive functional imaging of tumors. Considering their function in matrix remodeling, malignant melanoma appears as particularly interesting neoplasia in this respect. For the development of radiotracers that enable PET imaging of the melanoma-associated lysyl oxidase activity, substrates derived from the type I collagen α1 N-telopeptide were labeled with fluorine-18 using N-succinimidyl 4-[18F]fluorobenzoate ([18F]SFB) as prosthetic reagent. With regards to potential crosslinking to tumor-associated collagen in vivo, their interaction with triple-helical type I collagen was studied by SPR. A mouse model of human melanoma was established on the basis of the A375 cell line, for which the expression of the oncologically relevant lysyl oxidase isoforms LOX and LOXL2 was demonstrated in Western blot and immunohistochemical experiments. The radiopharmacological profiles of the peptidic radiotracers were evaluated in normal rats and A375 melanoma-bearing mice by ex vivo metabolite analysis, whole-body biodistribution studies and dynamic PET imaging. Out of three 18F-labeled telopeptide analogs, the one with the most favorable substrate properties has shown favorable tumor uptake and tumor-to-muscle ratio. Lysyl oxidase-mediated tumor uptake was proven by pharmacological inhibition using β-aminopropionitrile and by employing negative-control analogs of impeded or abolished targeting capability. The latter were obtained by substituting the lysine residue by ornithine and norleucine, respectively. Comparing the tumor uptake of the lysine-containing peptide with that of the non-functional analogs indicate the feasibility of lysyl oxidase imaging in melanoma using substrate-based radiotracers.

  3. Benefit of 18F-fluorocholine PET imaging in parathyroid surgery.

    PubMed

    Huber, G F; Hüllner, M; Schmid, C; Brunner, A; Sah, B; Vetter, D; Kaufmann, P A; von Schulthess, G K

    2018-06-01

    To assess the additional diagnostic value of 18 F-fluorocholine PET imaging in preoperative localization of pathologic parathyroid glands in clinically manifest hyperparathyroidism in case of negative or conflicting ultrasound and scintigraphy results. A retrospective, single-institution study of 26 patients diagnosed with hyperparathyroidism. In cases where ultrasound and scintigraphy failed to detect the location of an adenoma in order to allow a focused surgical approach, an additional 18 F-fluorocholine PET scan was performed and its results were compared with the intraoperative findings. A total of 26 patients underwent 18 F-fluorocholine PET/CT (n = 11) or PET/MRI (n = 15). Adenomas were detected in 25 patients (96.2%). All patients underwent surgery, and the location predicted by PET hybrid imaging was confirmed intraoperatively by frozen section and adequate parathyroid hormone drop after removal. None of the patients needed revision surgery during follow-up. These results demonstrate that 18 F-fluorocholine PET imaging is a highly accurate method to detect parathyroid adenomas even in case of previous localization failure by other imaging examinations. • With 18 F-fluorocholine PET imaging, parathyroid adenomas could be detected in 96.2%. • 18 F-fluorocholine imaging is a highly accurate method to detect parathyroid adenomas. • We encourage its use, where ultrasound fails to detect an adenoma.

  4. Human radiation dosimetry of 6-[{sup 18}F]FDG predicted from preclinical studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Muzic, Raymond F., E-mail: raymond.muzic@case.edu; Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio 44106; Case Center for Imaging Research, University Hospitals Case Medical Center, Case Western Reserve University, Cleveland, Ohio 44106

    Purpose: The authors are developing 6-[{sup 18}F]fluoro-6-deoxy-D-glucose (6-[{sup 18}F]FDG) as an in vivo tracer of glucose transport. While 6-[{sup 18}F]FDG has the same radionuclide half-life as 2-[{sup 18}F]fluoro-2-deoxy-D-glucose (2-[{sup 18}F]FDG) which is ubiquitously used for PET imaging, 6-[{sup 18}F]FDG has special biologic properties and different biodistributions that make it preferable to 2-[{sup 18}F]FDG for assessing glucose transport. In preparation for 6-[{sup 18}F]FDG use in human PET scanning, the authors would like to determine the amount of 6-[{sup 18}F]FDG to inject while maintaining radiation doses in a safe range. Methods: Rats were injected with 6-[{sup 18}F]FDG, euthanized at specified times, andmore » tissues were collected and assayed for activity content. For each tissue sample, the percent of injected dose per gram was calculated and extrapolated to that for humans in order to construct predicted time-courses. Residence times were calculated as areas under the curves and were used as inputs to OLINDA/EXM in order to calculate the radiation doses. Results: Unlike with 2-[{sup 18}F]FDG for which the urinary bladder wall receives the highest absorbed dose due to urinary excretion, with 6-[{sup 18}F]FDG there is little urinary excretion and osteogenic cells and the liver are predicted to receive the highest absorbed doses: 0.027 mGy/MBq (0.100 rad/mCi) and 0.018 mGy/MBq (0.066 rad/mCi), respectively. Also, the effective dose from 6-[{sup 18}F]FDG, i.e., 0.013 mSv/MBq (0.046 rem/mCi), is predicted to be approximately 30% lower than that from 2-[{sup 18}F]FDG. Conclusions: 6-[{sup 18}F]FDG will be safe for use in the PET scanning of humans.« less

  5. Predicting chemotherapy response to paclitaxel with 18F-Fluoropaclitaxel and PET.

    PubMed

    Hsueh, Wei-Ann; Kesner, Amanda L; Gangloff, Anne; Pegram, Mark D; Beryt, Malgorzata; Czernin, Johannes; Phelps, Michael E; Silverman, Daniel H S

    2006-12-01

    Paclitaxel is used as a chemotherapy drug for the treatment of various malignancies, including breast, ovarian, and lung cancers. To evaluate the potential of a noninvasive prognostic tool for specifically predicting the resistance of tumors to paclitaxel therapy, we examined the tumoral uptake of (18)F-fluoropaclitaxel ((18)F-FPAC) in mice bearing human breast cancer xenografts by using small-animal-dedicated PET and compared (18)F-FPAC uptake with the tumor response to paclitaxel treatment. PET data were acquired after tail vein injection of approximately 9 MBq of (18)F-FPAC in anesthetized nude mice bearing breast cancer xenografts. Tracer uptake in reconstructed images was quantified by region-of-interest analyses and compared with the tumor response, as measured by changes in tumor volume, after treatment with paclitaxel. Mice with tumors that progressed demonstrated lower tumoral uptake of (18)F-FPAC than mice with tumors that did not progress or that regressed (r = 0.55, P < 0.02; n = 19), indicating that low (18)F-FPAC uptake was a significant predictor of chemoresistance. Conversely, high (18)F-FPAC uptake predicted tumor regression. This relationship was found for mice bearing xenografts from cell lines selected to be either sensitive or intrinsically resistant to paclitaxel in vitro. PET data acquired with (18)F-FPAC suggest that this tracer holds promise for the noninvasive quantification of its distribution in vivo in a straightforward manner. In combination with approaches for examining other aspects of resistance, such quantification could prove useful in helping to predict subsequent resistance to paclitaxel chemotherapy of breast cancer.

  6. Chronic bacterial osteomyelitis: prospective comparison of (18)F-FDG imaging with a dual-head coincidence camera and (111)In-labelled autologous leucocyte scintigraphy.

    PubMed

    Meller, J; Köster, G; Liersch, T; Siefker, U; Lehmann, K; Meyer, I; Schreiber, K; Altenvoerde, G; Becker, W

    2002-01-01

    Indium-111-labelled white blood cells ((111)In-WBCs) are currently considered the tracer of choice in the diagnostic work-up of suspected active chronic osteomyelitis (COM). Previous studies in a limited number of patients, performed with dedicated PET systems, have shown that [(18)F]2'-deoxy-2-fluoro- D-glucose (FDG) imaging may offer at least similar diagnostic accuracy. The aim of this prospective study was to compare FDG imaging with a dual-head coincidence camera (DHCC) and (111)In-WBC imaging in patients with suspected COM. Thirty consecutive non-diabetic patients with possible COM underwent combined skeletal scintigraphy (30/30 patients), (111)In-WBC imaging (28/30 patients) and FDG-PET with a DHCC (30/30 patients). During diagnostic work-up, COM was proven in 11/36 regions of suspected skeletal infection and subsequently excluded in 25/36 regions. In addition, soft tissue infection was present in five patients and septic arthritis in three. (111)In-WBC imaging in 28 patients was true positive in 2/11 regions with proven COM and true negative in 21/23 regions without further evidence of COM. False-positive results occurred in two regions and false-negative results in nine regions suspected for COM. Most of the false-negative results (7/9) occurred in the central skeleton. If the analysis was restricted to the 18 regions with available histology ( n=17) or culture ( n=1), (111)In-WBC imaging was true positive in 2/18 regions, true negative in 8/18 regions, false negative in 7/18 regions and false positive in 1/18 regions. FDG-DHCC imaging was true positive in 11/11 regions with proven COM and true negative in 23/25 regions without further evidence of COM. False-positive results occurred in two regions. If the analysis was restricted to the 19 regions with available histology ( n=18) or culture ( n=1), FDG-DHCC imaging was true positive in 9/9 regions with proven COM and true negative in 10/10 regions without further evidence of COM. It is concluded that FDG

  7. Imaging Bone–Cartilage Interactions in Osteoarthritis Using [18F]-NaF PET-MRI

    PubMed Central

    Pedoia, Valentina; Seo, Youngho; Yang, Jaewon; Bucknor, Matt; Franc, Benjamin L.; Majumdar, Sharmila

    2016-01-01

    Purpose: Simultaneous positron emission tomography–magnetic resonance imaging (PET-MRI) is an emerging technology providing both anatomical and functional images without increasing the scan time. Compared to the traditional PET/computed tomography imaging, it also exposes the patient to significantly less radiation and provides better anatomical images as MRI provides superior soft tissue characterization. Using PET-MRI, we aim to study interactions between cartilage composition and bone function simultaneously, in knee osteoarthritis (OA). Procedures: In this article, bone turnover and remodeling was studied using [18F]-sodium fluoride (NaF) PET data. Quantitative MR-derived T1ρ relaxation times characterized the biochemical cartilage degeneration. Sixteen participants with early signs of OA of the knee received intravenous injections of [18F]-NaF at the onset of PET-MR image acquisition. Regions of interest were identified, and kinetic analysis of dynamic PET data provided the rate of uptake (Ki) and the normalized uptake (standardized uptake value) of [18F]-NaF in the bone. Morphological MR images and quantitative voxel-based T1ρ maps of cartilage were obtained using an atlas-based registration technique to segment cartilage automatically. Voxel-by-voxel statistical parameter mapping was used to investigate the relationship between bone and cartilage. Results: Increases in cartilage T1ρ, indicating degenerative changes, were associated with increased turnover in the adjoining bone but reduced turnover in the nonadjoining compartments. Associations between pain and increased bone uptake were seen in the absence of morphological lesions in cartilage, but the relationship was reversed in the presence of incident cartilage lesions. Conclusion: This study shows significant cartilage and bone interactions in OA of the knee joint using simultaneous [18F]-NaF PET-MR, the first in human study. These observations highlight the complex biomechanical and biochemical

  8. Impact of Endoscopic Ultrasonography on 18F-FDG-PET/CT Upfront Towards Patient Specific Esophageal Cancer Treatment.

    PubMed

    Hulshoff, J B; Mul, V E M; de Boer, H E M; Noordzij, W; Korteweg, T; van Dullemen, H M; Nagengast, W B; Oppedijk, V; Pierie, J P E N; Plukker, John Th M

    2017-07-01

    In patients with potentially resectable esophageal cancer (EC), the value of endoscopic ultrasonography (EUS) after fluorine-18 labeled fluorodeoxyglucose positron emission tomography with computed tomography ( 18 F-FDG-PET/CT) is questionable. Retrospectively, we assessed the impact of EUS after PET/CT on the given treatment in EC patients. During the period 2009-2015, 318 EC patients were staged as T1-4aN0-3M0 with hybrid 18 F-FDG-PET/CT or 18 F-FDG-PET with CT and EUS if applicable in a nonspecific order. We determined the impact of EUS on the given treatment in 279 patients who also were staged with EUS. EUS had clinical consequences if it changed curability, extent of radiation fields or lymph node resection (AJCC stations 2-5), and when the performed fine-needle aspiration (FNA) provided conclusive information of suspicious lymph node. EUS had an impact in 80 (28.7%) patients; it changed the radiation field in 63 (22.6%), curability in 5 (1.8%), lymphadenectomy in 48 (17.2%), and FNA was additional in 21 (7.5%). In patients treated with nCRT (n = 194), EUS influenced treatment in 53 (27.3%) patients; in 38 (19.6%) the radiation field changed, in 3 (1.5%) the curability, in 35 (18.0%) the lymphadenectomy, and in 17 (8.8%) FNA was additional. EUS influenced both the extent of radiation field and nodal resection in 31 (16.0%) nCRT patients. EUS had an impact on the given treatment in approximately 29%. In most patients, the magnitude of EUS found expression in the extent of radiotherapy target volume delineation to upper/high mediastinal lymph nodes.

  9. 18F-choline PET/MRI in suspected recurrence of prostate carcinoma.

    PubMed

    Riola-Parada, C; Carreras-Delgado, J L; Pérez-Dueñas, V; Garcerant-Tafur, M; García-Cañamaque, L

    2018-05-21

    To evaluate the usefulness of simultaneous 18 F-choline PET/MRI in the suspicion of prostate cancer recurrence and to relate 18 F-choline PET/MRI detection rate with analytical and pathological variables. 27 patients with prostate cancer who received local therapy as primary treatment underwent a 18 F-choline PET/MRI due to suspicion of recurrence (persistently rising serum PSA level). 18 F-choline PET/MRI findings were validated by anatomopathological analysis, other imaging tests or by biochemical response to oncological treatment. 18 F-choline PET/MRI detected disease in 15 of 27 patients (detection rate 55.56%). 4 (15%) presented exclusively local recurrence, 5 (18%) lymph node metastases and 7 (26%) bone metastases. Mean PSA (PSA med ) at study time was 2.94ng/mL (range 0.18-10ng/mL). PSA med in patients with positive PET/MRI was 3.70ng/mL (range 0.24-10ng/mL), higher than in patients with negative PET/MRI, PSA med 1.97ng/mL (range 0.18-4.38ng/mL), although without statistically significant differences. Gleason score at diagnosis in patients with a positive study was 7.33 (range 6-9) and in patients with a negative study was 7 (range 6-9), without statistically significant differences. 18 F-choline PET/MRI detection rate was considerable despite the relatively low PSA values in our sample. The influence of Gleason score and PSA level on 18 F-choline PET/MRI detection rate was not statistically significant. Copyright © 2018 Sociedad Española de Medicina Nuclear e Imagen Molecular. Publicado por Elsevier España, S.L.U. All rights reserved.

  10. Kinetic Modelling of Infection Tracers [18F]FDG, [68Ga]Ga-Citrate, [11C]Methionine, and [11C]Donepezil in a Porcine Osteomyelitis Model.

    PubMed

    Jødal, Lars; Jensen, Svend B; Nielsen, Ole L; Afzelius, Pia; Borghammer, Per; Alstrup, Aage K O; Hansen, Søren B

    2017-01-01

    Positron emission tomography (PET) is increasingly applied for infection imaging using [ 18 F]FDG as tracer, but uptake is unspecific. The present study compares the kinetics of [ 18 F]FDG and three other PET tracers with relevance for infection imaging. A juvenile porcine osteomyelitis model was used. Eleven pigs underwent PET/CT with 60-minute dynamic PET imaging of [ 18 F]FDG, [ 68 Ga]Ga-citrate, [ 11 C]methionine, and/or [ 11 C]donepezil, along with blood sampling. For infectious lesions, kinetic modelling with one- and two-tissue-compartment models was conducted for each tracer. Irreversible uptake was found for [ 18 F]FDG and [ 68 Ga]Ga-citrate; reversible uptake was found for [ 11 C]methionine (two-tissue model) and [ 11 C]donepezil (one-tissue model). The uptake rate for [ 68 Ga]Ga-citrate was slow and diffusion-limited. For the other tracers, the uptake rate was primarily determined by perfusion (flow-limited uptake). Net uptake rate for [ 18 F]FDG and distribution volume for [ 11 C]methionine were significantly higher for infectious lesions than for correspondingly noninfected tissue. For [ 11 C]donepezil in pigs, labelled metabolite products appeared to be important for the analysis. The kinetics of the four studied tracers in infection was characterized. For clinical applications, [ 18 F]FDG remains the first-choice PET tracer. [ 11 C]methionine may have a potential for detecting soft tissue infections. [ 68 Ga]Ga-citrate and [ 11 C]donepezil were not found useful for imaging of osteomyelitis.

  11. N-[18F]-FluoropropylJDTic for κ-opioid receptor PET imaging: Radiosynthesis, pre-clinical evaluation, and metabolic investigation in comparison with parent JDTic.

    PubMed

    Schmitt, Sébastien; Delamare, Jérôme; Tirel, Olivier; Fillesoye, Fabien; Dhilly, Martine; Perrio, Cécile

    2017-01-01

    To image kappa opioid receptor (KOR) for preclinical studies, N-fluoropropylJDTic 9 derived from the best-established KOR antagonist JDTic, was labeled with fluorine-18. Radiosynthesis of [ 18 F]9 was achieved according to an automated two-step procedure from [ 18 F]-fluoride. Peripheral and cerebral distributions were determined by ex vivo experiments and by PET imaging in mouse. Radiometabolism studies were performed both in vivo in mice and in vitro in mouse and human liver microsomes. Identification of the major metabolic fragmentations was carried out by UPLC-MS analysis of enzymatic cleavage of non-radioactive ligand 9. Microsomal metabolic degradation of parent JDTic was also achieved for comparison. The radiotracer [ 18 F]9 was produced after 140±5min total synthesis time (2.2±0.4% not decay corrected radiochemical yield) with a specific activity of 41-89GBq/μmol (1.1-2.4Ci/μmol). Peripheral and regional brain distributions of [ 18 F]9 were consistent with known KOR locations but no significant specific binding in brain was shown. [ 18 F]9 presented a typical hepatobiliary and renal elimination, and was rapidly metabolized. The in vivo and in vitro radiometabolic profiles of [ 18 F]9 were similar. Piperidine 12 was identified as the major metabolic fragment of the non-radioactive ligand 9. JDTic 7 was found to be much more stable than 9. Although the newly proposed radioligand [ 18 F]9 was concluded to be not suitable for KOR PET imaging due to the formation of brain penetrating radiometabolites, our findings highlight the metabolic stability of JDTic and may help in the design of novel JDTic derivatives for in vivo applications. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Comparison of 68Ga-PSMA-11 and 18F-Fluciclovine PET/CT in a Case Series of 10 Patients with Prostate Cancer Recurrence.

    PubMed

    Calais, Jeremie; Fendler, Wolfgang P; Herrmann, Ken; Eiber, Matthias; Ceci, Francesco

    2018-05-01

    This was a head-to-head comparison between 68 Ga-labeled prostate-specific membrane antigen (PSMA)-11 and 18 F-fluciclovine PET/CT in a series of 10 patients with prostate cancer (PCa) recurrence. Methods: In total, 288 patients with PCa recurrence were enrolled in a prospective study of 68 Ga-PSMA-11 PET/CT imaging for recurrent disease localization (ClinicalTrials.gov identifier NCT02940262). We retrospectively identified 10 patients who underwent clinically indicated 18 F-fluciclovine PET/CT prior to enrollment. Results: The median time between the 2 scans was 2.2 mo (range, 0.2-4.2 mo). The median prostate-specific antigen (PSA) value was 1.0 ng/mL (mean, 4.7 ng/mL; range, 0.13-18.1 ng/mL) and 1.1 ng/mL (mean, 6.2 ng/mL; range, 0.24-31.3 ng/mL) at the time of 18 F-fluciclovine and 68 Ga-PSMA-11 PET/CT, respectively. Five of 10 patients (50%) were negative with 18 F-fluciclovine but positive with 68 Ga-PSMA-11 PET/CT. Two of 10 patients (20%) were positive with both 18 F-fluciclovine and 68 Ga-PSMA-11 PET/CT, but 68 Ga-PSMA-11 PET/CT showed additional lymph nodes metastasis. Three of 10 patients (30%) were negative with both 18 F-fluciclovine and 68 Ga-PSMA-11 PET/CT. Conclusion: This case series suggests improved detection rates for 68 Ga-PSMA-11 PET/CT when compared with 18 F-fluciclovine PET/CT in patients with recurrent PCa. Prospective trials designed to directly compare the two should be initiated. © 2018 by the Society of Nuclear Medicine and Molecular Imaging.

  13. Evaluation of Phosphatidylserine-Binding Peptides Radiolabeled with Fluorine 18 for in vivo Imaging of Apoptosis

    NASA Astrophysics Data System (ADS)

    Kapty, Janice Sarah

    We currently do not have a clinical method to directly assess apoptosis induced by cancer therapies. Phosphatidylserine (PS) is an attractive target for imaging apoptosis since it is on the exterior of the apoptotic cells and PS externalization is an early marker of apoptosis. PS-binding peptides are an attractive option for developing an imaging probe to detect apoptosis using positron emission tomography. In this study we evaluated binding characteristics of PS-binding peptides for ability to bind to PS, radiolabeled PS-binding peptides with fluorine-18, and performed in vitro and in vivo analysis of 18F radiolabeled PS-binding peptides including biodistribution analysis and dynamic PET imaging in a murine tumor model of apoptosis. Four peptides were evaluated for PS binding characteristics using a plate based assay system, a liposome mimic of cell membrane PS presentation, and a cell assay of apoptosis. The results indicate that all four peptides bind to PS and are specific to apoptotic cells. The widely used 18 F prosthetic group N-succinimidyl-4-[18F]fluorobenzoate ([18F]SFB) and the recently developed N-[6-(4-[ 18F]fluorobenzylidene) aminooxyhexyl]maleimide ([18F]FBAM) were investigated for radiolabeling of two representative phosphatidylserine-binding peptides. The prosthetic groups were compared with respect to required reaction conditions for optimum labeling, radiolabeling yield and chemoselectivity. The N-terminus labeled product produced by reaction of [18F]SFB with binding peptide LIKKPF was produced in 18% radiochemical yield while no N-terminus labeled product could be isolated following [18F]SFB reaction with PDGLSR. When the peptides were modified by addition of a cysteine residue at the N-terminus they provided almost quantitative radiochemical yields with [18F]FBAM. Results indicate that for the peptides in this study, [18F]FBAM is a more useful prosthetic group compared to [18F]SFB due to its excellent chemo-selectivity and high radiochemical

  14. Automated radiosynthesis of Al[18F]PSMA-11 for large scale routine use.

    PubMed

    Kersemans, Ken; De Man, Kathia; Courtyn, Jan; Van Royen, Tessa; Piron, Sarah; Moerman, Lieselotte; Brans, Boudewijn; De Vos, Filip

    2018-05-01

    We report a reproducible automated radiosynthesis for large scale batch production of clinical grade Al[ 18 F]PSMA-11. A SynthraFCHOL module was optimized to synthesize Al[ 18 F]PSMA-11 by Al[ 18 F]-chelation. Results Al[ 18 F]PSMA-11 was synthesized within 35min in a yield of 21 ± 3% (24.0 ± 6.0GBq) and a radiochemical purity > 95%. Batches were stable for 4h and conform the European Pharmacopeia guidelines. The automated synthesis of Al[ 18 F]PSMA-11 allows for large scale production and distribution of Al[ 18 F]PSMA-11. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. Peptide and protein quantitation by acid-catalyzed 18O-labeling of carboxyl groups.

    PubMed

    Haaf, Erik; Schlosser, Andreas

    2012-01-03

    We have developed a new method that applies acidic catalysis with hydrochloric acid for (18)O-labeling of peptides at their carboxyl groups. With this method, peptides get labeled at their C-terminus, at Asp and Glu residues, and at carboxymethylated cysteine residues. Oxygen atoms at phosphate groups of phosphopeptide are not exchanged. Our elaborated labeling protocol is easy to perform, fast (5 h and 30 min), and results in 95-97 atom % incorporation of (18)O at carboxyl groups. Undesired side reactions, such as deamidation or peptide hydrolysis, occur only at a very low level under the conditions applied. In addition, data analysis can be performed automatically using common software tools, such as Mascot Distiller. We have demonstrated the capability of this method for the quantitation of peptides as well as for phosphopeptides. © 2011 American Chemical Society

  16. Correlation of inflammation assessed by 18F-FDG PET, active mineral deposition assessed by 18F-fluoride PET, and vascular calcification in atherosclerotic plaque: a dual-tracer PET/CT study.

    PubMed

    Derlin, Thorsten; Tóth, Zoltán; Papp, László; Wisotzki, Christian; Apostolova, Ivayla; Habermann, Christian R; Mester, Janos; Klutmann, Susanne

    2011-07-01

    Formation and progression of atherosclerotic plaque is a dynamic and complex process involving various pathophysiologic steps including inflammation and calcification. The purpose of this study was to compare macrophage activity as determined by (18)F-FDG PET and ongoing mineral deposition as measured by (18)F-sodium fluoride PET in atherosclerotic plaque and to correlate these findings with calcified plaque burden as assessed by CT. Forty-five patients were examined by whole-body (18)F-FDG PET, (18)F-sodium fluoride PET, and CT. Tracer uptake in various arterial segments was analyzed both qualitatively and semiquantitatively by measuring the blood-pool-corrected standardized uptake value (target-to-background ratio [TBR]). The pattern of tracer uptake in atherosclerotic lesions was compared after color-coded multistudy image fusion of PET and CT studies. The Fisher exact test and the Spearman correlation coefficient r(s) were used for statistical analysis of image-based results and cardiovascular risk factors. Intra- and interrater reproducibility were evaluated using the Cohen κ. (18)F-sodium fluoride uptake was observed at 105 sites in 27 (60%) of the 45 study patients, and mean TBR was 2.3 ± 0.7. (18)F-FDG uptake was seen at 124 sites in 34 (75.6%) patients, and mean TBR was 1.5 ± 0.3. Calcified atherosclerotic lesions were observed at 503 sites in 34 (75.6%) patients. Eighty-one (77.1%) of the 105 lesions with marked (18)F-sodium fluoride uptake and only 18 (14.5%) of the 124 lesions with (18)F-FDG accumulation were colocalized with arterial calcification. Coincident uptake of both (18)F-sodium fluoride and (18)F-FDG was observed in only 14 (6.5%) of the 215 arterial lesions with radiotracer accumulation. PET/CT with (18)F-FDG and (18)F-sodium fluoride may allow evaluation of distinct pathophysiologic processes in atherosclerotic lesions and might provide information on the complex interactions involved in formation and progression of atherosclerotic plaque.

  17. Synthesis of [{sup 18}F]Ro41-0960, a potent COMT inhibitor, for use in vivo mapping with PET

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ding, Y.S.; Sugano, Y.; Gatley, S.J.

    1995-05-01

    Catechol-O-methyltransferase (COMPT; EC 2.1.1.6) is one of the two major enzymes which metabolize the catecholamine neurotransmitters. It is distributed throughout the body and brain and is elevated in breast cancer tissue when it plays a role in estrogen metabolism. It is also an important molecular target in the development of drugs to treat Parkinson`s disease (PD). Because COMT regulates the concentration of important neurotransmitter amines such as dopamine, there is speculation that abnormalities in its activity may be associated with neurological, and psychiatric disorders. Ro41-9060(3,4-dihydroxy-5-nitro-2{prime}-fluorobenzophenone) is a potent, fluorine containing COMT inhibitor which has been reported to cross the bloodmore » brain barrier. It is structurally similar to Ro40-7592 which is currently undergoing clinical trials in PD. We report the synthesis of [{sup 18}F]Ro41-0960, for investigation for mapping COMT and for studies of COMT drugs. [{sup 18}F]Ro41-0960 was synthesized by the nucleophilic aromatic substitution reaction with NCA [{sup 18}F] fluoride on a protected precursor (prepared via a five-step synthesis) followed by hydrolysis with HBr (synthesis time of 100 min; radiochemical yield of 5-7% (EOB)). Though Ro41-0960 has been reported to cross the blood brain barrier, PET studies in baboon demonstrated that an almost complete absence of the drug from the brain both at tracer doses and with the addition of unlabeled drug (1.5 mg/kg) at all times through a 90 min experimental interval. The plasma to brain ratios of F-18 average about 40:1. However, high uptake was observed in the kidneys and in other organs which are known to have high COMT. Studies in mice showed that at 30 min after injection of tracer, F-18 in kidneys was largely as [{sup 18}F]Ro-41-0960 and that it could be displaced with unlabeled Ro41-0960. These studies provide the first example of a positron emitter labeled COMT radiotracer.« less

  18. 18F-FNDP for PET Imaging of Soluble Epoxide Hydrolase.

    PubMed

    Horti, Andrew G; Wang, Yuchuan; Minn, Il; Lan, Xi; Wang, Jian; Koehler, Raymond C; Alkayed, Nabil J; Dannals, Robert F; Pomper, Martin G

    2016-11-01

    Soluble epoxide hydrolase (sEH) is a bifunctional enzyme located within cytosol and peroxisomes that converts epoxides to the corresponding diols and hydrolyzes phosphate monoesters. It serves to inactivate epoxyeicosatrienoic acids (EETs), which are generated in the brain to couple neuronal activity and cerebral blood flow in normal and pathologic states. Altered regulation of sEH was observed previously in various neuropathologic disorders including vascular dementia and stroke. Inhibitors of sEH are pursued as agents to mitigate neuronal damage after stroke. We developed N-(3,3-diphenylpropyl)-6- 18 F-fluoronicotinamide ( 18 F-FNDP), which proved highly specific for imaging of sEH in the mouse and nonhuman primate brain with PET. 18 F-FNDP was synthesized from the corresponding bromo precursor. sEH inhibitory activity of 18 F-FNDP was measured using an sEH inhibitor screening assay kit. Biodistribution was undertaken in CD-1 mice. Binding specificity was assayed in CD-1 and sEH knock-out mice and Papio anubis (baboon) through pretreatment with an sEH inhibitor to block sEH binding. Dynamic PET imaging with arterial blood sampling was performed in 3 baboons, with regional tracer binding quantified using distribution volume. The metabolism of 18 F-FNDP in baboons was assessed using high-performance liquid chromatography. 18 F-FNDP (inhibition binding affinity constant, 1.73 nM) was prepared in 1 step in a radiochemical yield of 14% ± 7%, specific radioactivity in the range of 888-3,774 GBq/μmol, and a radiochemical purity greater than 99% using an automatic radiosynthesis module. The time of preparation was about 75 min. In CD-1 mice, regional uptake followed the pattern of striatum > cortex > hippocampus > cerebellum, consistent with the known brain distribution of sEH, with 5.2% injected dose per gram of tissue at peak uptake. Blockade of 80%-90% was demonstrated in all brain regions. Minimal radiotracer uptake was present in sEH knock-out mice. PET baboon

  19. Induction of Th1 polarized immune responses by thiolated Eudragit-coated F4 and F18 fimbriae of enterotoxigenic Escherichia coli.

    PubMed

    Lee, Won-Jung; Cha, Seungbin; Shin, Minkyoung; Islam, Mohammad Ariful; Cho, Chong-su; Yoo, Han Sang

    2011-10-01

    Diarrhea in newborn and weaned piglets is mainly induced by enterotoxigenic Escherichia coli (ETEC) with fimbriae F4 (K88) and F18 (F107). In this study, we evaluated F4 and F18 coated with thiolated Eudragit microspheres (TEMS) as a candidate for an oral vaccine. The average particle sizes of TEMS, F4-loaded TEMS, and F18-loaded TEMS were measured as 4.2±0.75 μm, 4.7±0.50 μm, and 4.5±0.37 μm, respectively. F4 is more efficiently encapsulated than F18 in the loading with TEMS. In the release test, F4 and F18 fimbriae were protected in acidic circumstances, whereas most were released at pH 7.4 of intestine circumstances. Production of TNF-α and NO from RAW 264.7 cells was increased in a time-dependent manner after exposure to all groups, whereas only F4- or F18-loaded TEMS-stimulated IL-6 secretion. The levels of IFN-γ from mouse splenocytes after exposure to F4 or F18 were increased while IL-4 was not detectable. These results suggest that F4- and F18-loaded TEMS may effectively induce immune response with the efficient release of antigens to appropriate target sites. Copyright © 2011 Elsevier B.V. All rights reserved.

  20. A rapid solid-phase extraction method for measurement of non-metabolised peripheral benzodiazepine receptor ligands, [(18)F]PBR102 and [(18)F]PBR111, in rat and primate plasma.

    PubMed

    Katsifis, Andrew; Loc'h, Christian; Henderson, David; Bourdier, Thomas; Pham, Tien; Greguric, Ivan; Lam, Peter; Callaghan, Paul; Mattner, Filomena; Eberl, Stefan; Fulham, Michael

    2011-01-01

    To develop a rapid and reliable method for estimating non-metabolised PBR ligands fluoroethoxy ([(18)F]PBR102)- and fluoropropoxy ([(18)F]PBR111)-substituted 2-(6-chloro-2-phenyl)imidazo[1,2-a]pyridine-3-yl)-N,N-diethylacetamides in plasma. Rats and baboons were imaged with PET up to 2 h postinjection of [(18)F]PBR102 and [(18)F]PBR111 under baseline conditions, after pre-blocking or displacement with PK11195. Arterial plasma samples were directly analysed by reverse-phase solid-phase extraction (RP-SPE) and RP-HPLC and by normal-phase TLC. SPE cartridges were successively washed with acetonitrile/water mixtures. SPE eluant radioactivity was measured in a γ-counter to determine the parent compound fraction and then analysed by HPLC and TLC for validation. In SPE, hydrophilic and lipophilic radiolabelled metabolites were eluted in water and 20% acetonitrile/water. All non-metabolised [(18)F]PBR102 and [(18)F]PBR111 were in SPE acetonitrile fraction as confirmed by HPLC and TLC analysis. Unchanged (%) [(18)F]PBR102 and [(18)F]PBR111 from SPE analysis in rat and baboon plasma agreed with those from HPLC and TLC analysis. In rats and baboons, the fraction of unchanged tracer followed a bi-exponential decrease, with half-lives of 7 to 10 min for the fast component and >80 min for the slow component for both tracers. Direct plasma SPE analysis of [(18)F]PBR102 and [(18)F]PBR111 can reliably estimate parent compound fraction. SPE was superior to HPLC for samples with low activity; it allows rapid and accurate metabolite analysis of a large number of plasma samples for improved estimation of metabolite-corrected input function during quantitative PET imaging studies. Crown Copyright © 2011. Published by Elsevier Inc. All rights reserved.

  1. PET quantification of 5-HT2A receptors in the human brain: a constant infusion paradigm with [18F]altanserin.

    PubMed

    van Dyck, C H; Tan, P Z; Baldwin, R M; Amici, L A; Garg, P K; Ng, C K; Soufer, R; Charney, D S; Innis, R B

    2000-02-01

    [18F]altanserin has been used to label serotonin 5-HT2A receptors, which are believed to be important in the pathophysiology of schizophrenia and depression. The purpose of this study was to test the feasibility of a constant infusion paradigm for equilibrium modeling of [18F]altanserin with PET. Kinetic modeling with [18F]altanserin may be hampered by the presence of lipophilic radiometabolites observed in plasma after intravenous administration. Eight healthy volunteers were injected with [18F]altanserin as a bolus (208+/-9 MBq [5.62+/-0.25 mCi]) plus constant infusion (65+/-3 MBq/h [1.76+/-0.08 mCi/h]) ranging from 555 to 626 min (615+/-24 min) after injection. PET acquisitions (10-20 min) and venous blood sampling were performed every 30-60 min throughout the infusion period. Linear regression analysis revealed that time-activity curves for both brain activity and plasma [18F]altanserin and metabolite concentrations stabilized after about 6 h. This permitted equilibrium modeling and estimation of V3' (ratio of specific uptake [cortical-cerebellar] to total plasma parent concentration after 6 h). Values of V3' ranged from 1.57+/-0.38 for anterior cingulate cortex to 1.02+/-0.39 for frontal cortex. The binding potential V3 (ratio of specific uptake to free plasma parent concentration after 6 h, using group mean f1) was also calculated and ranged from 169+/-41 for anterior cingulate cortex to 110+/-42 for frontal cortex. From 6 h onward, the rate of change for V3' and V3 was only 1.11+/-1.69 %/h. These results demonstrate the feasibility of equilibrium imaging with [18F]altanserin over more than 5 radioactive half-lives and suggest a method to overcome difficulties associated with lipophilic radiolabeled metabolites. The stability in V3 and V3' once equilibrium is achieved suggests that a single PET acquisition obtained at 6 h may provide a reasonable measure of 5-HT2A receptor density.

  2. Selective 2-( sup 18 F)fluorodopa uptake for melanogenesis in murine metastatic melanomas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ishiwata, K.; Kubota, K.; Kubota, R.

    The relationship between 3,4-dihydroxy-2-({sup 18}F)fluoro-L-phenylalanine (2-({sup 18}F)FDOPA) uptake and melanogenesis was studied using mice bearing two B16 melanomas: B16-F1 has a higher melanin synthesis ability and a slower growing rate than the higher metastatic B16-F10. A significantly higher 2-({sup 18}F)FDOPA uptake by B16-F1 than by B16-F10 and a reverse relationship for the uptake of ({sup 14}C) 2-deoxy-2-fluoro-D-glucose and ({sup 3}H)thymidine were observed 1 hr postinjection. F1-to-F10 ratios of both the 2-({sup 18}F)FDOPA uptake and the acid-insoluble radioactivity increased to about 5 at 6 hr, which paralleled the melanin content. FM3A mammary carcinoma showed a 2-({sup 18}F)FDOPA uptake similar to themore » B16-F10 but without the acid-insoluble radioactivity. With D,L-DOPA loading, a 55% decreased uptake by FM3A 1 hr postinjection was significantly greater than the 20% reduction in both melanomas. O-Methylated 2-({sup 18}F)FDOPA was a predominant acid-soluble metabolite in all tumors. Whole-body autoradiography discriminated the two melanomas clearly. 2-({sup 18}F)FDOPA may be a promising tracer for the selective imaging of melanogenesis.« less

  3. Spatial-Temporal [{sup 18}F]FDG-PET Features for Predicting Pathologic Response of Esophageal Cancer to Neoadjuvant Chemoradiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tan, Shan; Department of Control Science and Engineering, Huazhong University of Science and Technology, Wuhan; Kligerman, Seth

    2013-04-01

    Purpose: To extract and study comprehensive spatial-temporal {sup 18}F-labeled fluorodeoxyglucose ([{sup 18}F]FDG) positron emission tomography (PET) features for the prediction of pathologic tumor response to neoadjuvant chemoradiation therapy (CRT) in esophageal cancer. Methods and Materials: Twenty patients with esophageal cancer were treated with trimodal therapy (CRT plus surgery) and underwent [{sup 18}F]FDG-PET/CT scans both before (pre-CRT) and after (post-CRT) CRT. The 2 scans were rigidly registered. A tumor volume was semiautomatically delineated using a threshold standardized uptake value (SUV) of ≥2.5, followed by manual editing. Comprehensive features were extracted to characterize SUV intensity distribution, spatial patterns (texture), tumor geometry, andmore » associated changes resulting from CRT. The usefulness of each feature in predicting pathologic tumor response to CRT was evaluated using the area under the receiver operating characteristic curve (AUC) value. Results: The best traditional response measure was decline in maximum SUV (SUV{sub max}; AUC, 0.76). Two new intensity features, decline in mean SUV (SUV{sub mean}) and skewness, and 3 texture features (inertia, correlation, and cluster prominence) were found to be significant predictors with AUC values ≥0.76. According to these features, a tumor was more likely to be a responder when the SUV{sub mean} decline was larger, when there were relatively fewer voxels with higher SUV values pre-CRT, or when [{sup 18}F]FDG uptake post-CRT was relatively homogeneous. All of the most accurate predictive features were extracted from the entire tumor rather than from the most active part of the tumor. For SUV intensity features and tumor size features, changes were more predictive than pre- or post-CRT assessment alone. Conclusion: Spatial-temporal [{sup 18}F]FDG-PET features were found to be useful predictors of pathologic tumor response to neoadjuvant CRT in esophageal cancer.« less

  4. 19F-perfluorocarbon-labeled human peripheral blood mononuclear cells can be detected in vivo using clinical MRI parameters in a therapeutic cell setting.

    PubMed

    Fink, Corby; Gaudet, Jeffrey M; Fox, Matthew S; Bhatt, Shashank; Viswanathan, Sowmya; Smith, Michael; Chin, Joseph; Foster, Paula J; Dekaban, Gregory A

    2018-01-12

    A 19 Fluorine ( 19 F) perfluorocarbon cell labeling agent, when employed with an appropriate cellular MRI protocol, allows for in vivo cell tracking. 19 F cellular MRI can be used to non-invasively assess the location and persistence of cell-based cancer vaccines and other cell-based therapies. This study was designed to determine the feasibility of labeling and tracking peripheral blood mononuclear cells (PBMC), a heterogeneous cell population. Under GMP-compliant conditions human PBMC were labeled with a 19 F-based MRI cell-labeling agent in a manner safe for autologous re-injection. Greater than 99% of PBMC labeled with the 19 F cell-labeling agent without affecting functionality or affecting viability. The 19 F-labeled PBMC were detected in vivo in a mouse model at the injection site and in a draining lymph node. A clinical cellular MR protocol was optimized for the detection of PBMC injected both at the surface of a porcine shank and at a depth of 1.2 cm, equivalent to depth of a human lymph node, using a dual 1 H/ 19 F dual switchable surface radio frequency coil. This study demonstrates it is feasible to label and track 19 F-labeled PBMC using clinical MRI protocols. Thus, 19 F cellular MRI represents a non-invasive imaging technique suitable to assess the effectiveness of cell-based cancer vaccines.

  5. [18F]MEL050 as a melanin-targeted PET tracer: Fully automated radiosynthesis and comparison to 18F-FDG for the detection of pigmented melanoma in mice primary subcutaneous tumors and pulmonary metastases.

    PubMed

    Rizzo-Padoin, Nathalie; Chaussard, Michael; Vignal, Nicolas; Kotula, Ewa; Tsoupko-Sitnikov, Vadim; Vaz, Sofia; Hontonnou, Fortune; Liu, Wang-Qing; Poyet, Jean-Luc; Vidal, Michel; Merlet, Pascal; Hosten, Benoit; Sarda-Mantel, Laure

    2016-12-01

    Melanoma is a highly malignant cutaneous tumor of melanin-producing cells. MEL050 is a synthetic benzamide-derived molecule that specifically binds to melanin with high affinity. Our aim was to implement a fully automated radiosynthesis of [ 18 F]MEL050, using for the first time, the AllInOne™ synthesis module (Trasis), and to evaluate the potential of [ 18 F]MEL050 for the detection of pigmented melanoma in mice primary subcutaneous tumors and pulmonary metastases, and to compare it with that of [ 18 F]FDG. Automated radiosynthesis of [ 18 F]MEL050, including HPLC purification and formulation, were performed on an AllInOne™ synthesis module. [ 18 F]MEL050 was synthesized using a one-step bromine-for-fluorine nucleophilic heteroaromatic substitution. Melanoma models were induced by subcutaneous (primary tumor) or intravenous (pulmonary metastases) injection of B16-F10-luc2 cells in NMRI mice. The maximum percentage of [ 18 F]MEL050 Injected Dose per g of lung tissue (%ID/g Max) was determined on PET images, compared to [ 18 F]FDG and correlated to in vivo bioluminescence imaging. The automated radiosynthesis of [ 18 F]MEL050 required an overall radiosynthesis time of 48min, with a yield of 13-18% (not-decay corrected) and radiochemical purity higher than 99%. [ 18 F]MEL050 PET/CT images were concordant with bioluminescence imaging, showing increased radiotracer uptake in all primary subcutaneous tumors and pulmonary metastases of mice. PET quantification of radiotracers uptake in tumors and muscles demonstrated similar tumor-to-background ratio (TBR) with [ 18 F]MEL050 and [ 18 F]FDG in subcutaneous tumors and higher TBR with [ 18 F]MEL050 than with [ 18 F]FDG in pulmonary metastases. We successfully implemented the radiosynthesis of [ 18 F]MEL050 using the AllInOne™ module, including HPLC purification and formulation. In vivo PET/CT validation of [ 18 F]MEL050 was obtained in mouse models of pigmented melanoma, where higher [ 18 F]MEL050 uptake was observed

  6. Reduced dimethylaminoethanol in [(18)F]fluoromethylcholine: an important step towards enhanced tumour visualization.

    PubMed

    Slaets, Dominique; De Bruyne, Sylvie; Dumolyn, Caroline; Moerman, Lieselotte; Mertens, Koen; De Vos, Filip

    2010-11-01

    [(18)F]Fluoromethylcholine ([(18)F]FCho) is a radiotracer generally used for tumour visualization in patients. Due to high levels of dimethylaminoethanol (DMAE) remaining in [(18)F]FCho solutions synthesized by currently available methods, tumour visualization might be compromised. An improved purification method involving an optimized purification step for reducing the levels of DMAE was conceived. The physiological explanation for the interference of residual DMAE in [(18)F]FCho pharmacokinetics was further elaborated in a xenograft mouse model. The use of a series of polymer solid-phase extraction cartridges (Oasis HLB/WCX), instead of the commonly used combination of tC18 and Accell CM cartridges, reduced DMAE levels from 402.2±49.6 ppm to 3.0±0.5 ppm. Subsequent in vitro tests proved that (1) [(18)F]FCho uptake was reduced in the presence of DMAE at concentrations above 0.5 µM and (2) DMAE is a competitive inhibitor of [(18)F]FCho transport. In vivo experiments in xenograft mouse models corroborated reduced tumour uptake at DMAE plasma levels of about 2.5 µM as found in patients injected with contaminated [(18)F]FCho. Residual DMAE, even at levels below choline plasma concentrations found during fasting, compromises [(18)F]FCho uptake in vivo and care should be taken to avoid its interference in molecular imaging with [(18)F]FCho.

  7. A novel semi-robotized device for high-precision 18F-FDG-guided breast cancer biopsy.

    PubMed

    Hellingman, D; Teixeira, S C; Donswijk, M L; Rijkhorst, E J; Moliner, L; Alamo, J; Loo, C E; Valdés Olmos, R A; Stokkel, M P M

    To assess the 3D geometric sampling accuracy of a new PET-guided system for breast cancer biopsy (BCB) from areas within the tumour with high 18 F-FDG uptake. In the context of the European Union project MammoCare, a prototype semi-robotic stereotactic prototype BCB-device was incorporated into a dedicated high resolution PET-detector for breast imaging. The system consists of 2 stacked rings, each containing 12 plane detectors, forming a dodecagon with a 186mm aperture for 3D reconstruction (1mm 3 voxel). A vacuum-assisted biopsy needle attached to a robot-controlled arm was used. To test the accuracy of needle placement, the needle tip was labelled with 18 F-FDG and positioned at 78 target coordinates distributed over a 35mm×24mm×28mm volume within the PET-detector field-of-view. At each position images were acquired from which the needle positioning accuracy was calculated. Additionally, phantom-based biopsy proofs, as well as MammoCare images of 5 breast cancer patients, were evaluated for the 3D automated locating of 18 F-FDG uptake areas within the tumour. Needle positioning tests revealed an average accuracy of 0.5mm (range 0-1mm), 0.6mm (range 0-2mm), and 0.4mm (range 0-2mm) for the x/y/z-axes, respectively. Furthermore, the MammoCare system was able to visualize and locate small (<10mm) regions with high 18 F-FDG uptake within the tumour suitable for PET-guided biopsy after being located by the 3D automated application. Accuracy testing demonstrated high-precision of this semi-automatic 3D PET-guided system for breast cancer core needle biopsy. Its clinical feasibility evaluation in breast cancer patients scheduled for neo-adjuvant chemotherapy will follow. Copyright © 2016 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  8. (18)F-FBPA as a tumor specific tracer of L-type amino acid transporter 1 (LAT1): PET evaluation in tumor and inflammation compared to (18)F-FDG and (11)C-methionine.

    PubMed

    Watabe, Tadashi; Hatazawa, Jun

    2015-01-01

    (18)F-FDG-PET is used worldwide for oncology patients. However, we sometimes encounter false positive cases of (18)F-FDG PET, such as moderate uptake in the inflammatory lesion, because (18)F-FDG accumulates not only in the cancer cells but also in the inflammatory cells (macrophage, granulation tissue, etc). To overcome this limitation of (18)F-FDG, we started to use (4-borono-2- [(18)F]fluoro-L-phenylalanine) (18)F-FBPA, an artificial amino acid tracer which is focusing attention as a tumor specific PET tracer. Physiological accumulation of (18)F-FBPA is limited in the kidney and urinary tract in humans, which enable preferable evaluation of uptake in the abdominal organs compared to (11)C-methionine ((11)C-MET). The purpose of this study was to evaluate (18)F-FBPA as a tumor specific tracer by in vitro cellular uptake analysis focusing on the selectivity of L-type amino acid transporter 1 (LAT1), which is specifically expressed in tumor cells, and in vivo PET analysis in rat xenograft and inflammation models compared to (18)F-FDG and (11)C-methionine. Uptake inhibition and efflux experiments were performed in HEK293-LAT1 and LAT2 cells using cold BPA, cold (18)F-FBPA, and hot (18)F-FBPA to evaluate LAT affinity and transport capacity. Position emission tomography studies were performed in rat xenograft model of C6 glioma 2 weeks after the implantation (n=9, body weight=197±10.5g) and subcutaneous inflammation model 4 days after the injection of turpentine oil (n=9, body weight=197±14.4g). Uptake on static PET images were compared among (18)F-FBPA at 60-70min post injection, (18)F-FDG at 60-70min, and (11)C-MET at 20-30min in the tumors and the inflammatory lesions by maximum standardized uptake value (SUVmax). Cellular uptake analysis showed no significant difference in inhibitory effect and efflux of LAT1 between cold (18)F-FBPA and cold BPA, suggesting the same affinity and transport capacity via LAT1. Uptake of (18)F-FBPA via LAT1 was superior to LAT2 by

  9. 18F-Fluorosulfate for PET Imaging of the Sodium-Iodide Symporter: Synthesis and Biologic Evaluation In Vitro and In Vivo.

    PubMed

    Khoshnevisan, Alex; Chuamsaamarkkee, Krisanat; Boudjemeline, Mehdi; Jackson, Alex; Smith, Gareth E; Gee, Antony D; Fruhwirth, Gilbert O; Blower, Philip J

    2017-01-01

    Anion transport by the human sodium-iodide symporter (hNIS) is an established target for molecular imaging and radionuclide therapy. Current radiotracers for PET of hNIS expression are limited to 124 I - and 18 F-BF 4 - We sought new 18 F-labeled hNIS substrates offering higher specific activity, higher affinity, and simpler radiochemical synthesis than 18 F-BF 4 - METHODS: The ability of a range of anions, some containing fluorine, to block 99m TcO 4 - uptake in hNIS-expressing cells was measured. SO 3 F - emerged as a promising candidate. 18 F-SO 3 F - was synthesized by reaction of 18 F - with SO 3 -pyridine complex in MeCN and purified using alumina and quaternary methyl ammonium solid-phase extraction cartridges. Chemical and radiochemical purity and serum stability were determined by radiochromatography. Radiotracer uptake and efflux in hNIS-transduced HCT116-C19 cells and the hNIS-negative parent cell line were evaluated in vitro in the presence and absence of a known competitive inhibitor (NaClO 4 ). PET/CT imaging and ex vivo biodistribution measurement were conducted on BALB/c mice, with and without NaClO 4 inhibition. Fluorosulfate was identified as a potent inhibitor of 99m TcO 4 - uptake via hNIS in vitro (half-maximal inhibitory concentration, 0.55-0.56 μM (in comparison with 0.29-4.5 μM for BF 4 - , 0.07 μM for TcO 4 - , and 2.7-4.7 μM for I - ). Radiolabeling to produce 18 F-SO 3 F - was simple and afforded high radiochemical purity suitable for biologic evaluation (radiochemical purity > 95%, decay-corrected radiochemical yield = 31.6%, specific activity ≥ 48.5 GBq/μmol). Specific, blockable hNIS-mediated uptake in HCT116-C19 cells was observed in vitro, and PET/CT imaging of normal mice showed uptake in thyroid, salivary glands (percentage injected dose/g at 30 min, 563 ± 140 and 32 ± 9, respectively), and stomach (percentage injected dose/g at 90 min, 68 ± 21). Fluorosulfate is a high-affinity hNIS substrate. 18 F-SO 3 F - is easily

  10. 18F-FDG PET/CT Imaging of Primary Gastric Lymphoma.

    PubMed

    Davis, Brady S; Thompson, Trevor A; Wolin, Ely A

    2016-12-01

    Primary gastric lymphoma (PGL) accounts for less than 4% of gastric neoplasms. 18 F-FDG PET with simultaneously acquired CT ( 18 F-FDG PET/CT) allows for staging and differentiation from other gastric cancers. Rapid diagnosis and staging are important because chemotherapeutic response is generally favorable. We describe a case of an 83-y-old woman with stage II 1 PGL. 18 F-FDG PET/CT can be helpful to differentiate various gastric masses and is an important factor in the staging of PGL. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  11. Radioimmunotherapy of nude mice with intraperitoneally growing ovarian cancer xenograft utilizing 211At-labelled monoclonal antibody MOv18.

    PubMed

    Andersson, H; Lindegren, S; Back, T; Jacobsson, L; Leser, G; Horvath, G

    2000-01-01

    The aim of this study was to investigate the therapeutic efficacy of 211At-labelled monoclonal antibody given intraperitoneally to nude mice with intraperitoneal growth of a human ovarian cancer cell line. Female nude mice were inoculated intraperitoneally with 1 x 10(7) cells of the human ovarian cancer cell line NIH:OVCAR 3. After about two weeks they were injected with the 211At-labelled specific monoclonal antibody MOv18 intraperitoneally. For comparison, other groups of mice were given the same labelled antibody intravenously, 211At-labelled unspecific antibody C242 intraperitoneally or unalbelled MOv18 intraperitoneally. Six weeks later the animals were sacrificed and the occurrence of tumour and ascites was determined. When the mice were treated with 211At-labelled MOv18 intraperitoneally 9 out of 10 were apparently free of both ascites and tumour compared to none of the mice given unlabelled antibody. 211At-labelled MOv18 given intravenously or 211At-labelled unspecific antibody given intraperitoneally were less effective. Regional radioimmunotherapy with the alpa-emitter 211Astatine seems to be an effective treatment of nude mice with intraperitoneally growing human ovarian cancer. Hopefully this treatment can be given in an adjuvant setting to women with minimal residual ovarian cancer in the future.

  12. 18O-labeled proteome reference as global internal standards for targeted quantification by selected reaction monitoring-mass spectrometry.

    PubMed

    Kim, Jong-Seo; Fillmore, Thomas L; Liu, Tao; Robinson, Errol; Hossain, Mahmud; Champion, Boyd L; Moore, Ronald J; Camp, David G; Smith, Richard D; Qian, Wei-Jun

    2011-12-01

    Selected reaction monitoring (SRM)-MS is an emerging technology for high throughput targeted protein quantification and verification in biomarker discovery studies; however, the cost associated with the application of stable isotope-labeled synthetic peptides as internal standards can be prohibitive for screening a large number of candidate proteins as often required in the preverification phase of discovery studies. Herein we present a proof of concept study using an (18)O-labeled proteome reference as global internal standards (GIS) for SRM-based relative quantification. The (18)O-labeled proteome reference (or GIS) can be readily prepared and contains a heavy isotope ((18)O)-labeled internal standard for every possible tryptic peptide. Our results showed that the percentage of heavy isotope ((18)O) incorporation applying an improved protocol was >99.5% for most peptides investigated. The accuracy, reproducibility, and linear dynamic range of quantification were further assessed based on known ratios of standard proteins spiked into the labeled mouse plasma reference. Reliable quantification was observed with high reproducibility (i.e. coefficient of variance <10%) for analyte concentrations that were set at 100-fold higher or lower than those of the GIS based on the light ((16)O)/heavy ((18)O) peak area ratios. The utility of (18)O-labeled GIS was further illustrated by accurate relative quantification of 45 major human plasma proteins. Moreover, quantification of the concentrations of C-reactive protein and prostate-specific antigen was illustrated by coupling the GIS with standard additions of purified protein standards. Collectively, our results demonstrated that the use of (18)O-labeled proteome reference as GIS provides a convenient, low cost, and effective strategy for relative quantification of a large number of candidate proteins in biological or clinical samples using SRM.

  13. Regional distribution and kinetics of [18F]fluciclovine (anti-[18F]FACBC), a tracer of amino acid transport, in subjects with primary prostate cancer.

    PubMed

    Sörensen, Jens; Owenius, Rikard; Lax, Michelle; Johansson, Silvia

    2013-02-01

    [(18)F]Fluciclovine (anti-[(18)F]FACBC) is a synthetic amino acid developed for PET assessment of the anabolic component of tumour metabolism in clinical routine. This phase 1 trial evaluated the safety, tracer stability and uptake kinetics of [(18)F]fluciclovine in patients. Six patients with biopsy-proven prostate cancer were investigated with 3-T MRI and PET/CT. All underwent dynamic [(18)F]fluciclovine PET/CT of the pelvic area for up to 120 min after injection of 418 ± 10 MBq of tracer with simultaneous blood sampling of radioactivity. The kinetics of uptake in tumours and normal tissues were evaluated using standardized uptake values (SUVs) and compartmental modelling. Tumour deposits as defined by MRI were clearly visualized by PET. Urine excretion was minimal and normal tissue background was low. Uptake of [(18)F]fluciclovine in tumour from the blood was rapid and the tumour-to-normal tissue contrast was highest between 1 and 15 min after injection with a 65 % reduction in mean tumour uptake at 90 min after injection. A one-compartment model fitted the tracer kinetics well. Early SUVs correlated well with both the influx rate constant (K (1)) and the volume of distribution of the tracer (V (T)). There were no signs of tracer metabolite formation. The product was well tolerated in all patients without significant adverse events. [(18)F]Fluciclovine shows high uptake in prostate cancer deposits and appears safe for use in humans. The production is robust and the formulation stable in vivo. An early imaging window seems to provide the best visual results. SUV measurements capture most of the kinetic information that can be obtained from more advanced models, potentially simplifying quantification in future studies.

  14. Dosimetry and first clinical evaluation of the new 18F-radiolabeled bombesin analogue BAY 864367 in patients with prostate cancer.

    PubMed

    Sah, Bert-Ram; Burger, Irene A; Schibli, Roger; Friebe, Matthias; Dinkelborg, Ludger; Graham, Keith; Borkowski, Sandra; Bacher-Stier, Claudia; Valencia, Ray; Srinivasan, Ananth; Hany, Thomas F; Mu, Linjing; Wild, Peter J; Schaefer, Niklaus G

    2015-03-01

    The aim of this first-in-man study was to demonstrate the feasibility, safety, and tolerability, as well as provide dosimetric data and evaluate the imaging properties, of the bombesin analogue BAY 864367 for PET/CT in a small group of patients with primary and recurrent prostate cancer (PCa). Ten patients with biopsy-proven PCa (5 with primary PCa and 5 with prostate-specific antigen recurrence after radical prostatectomy) were prospectively selected for this exploratory clinical trial with BAY 864367, a new (18)F-labeled bombesin analogue. PET scans were assessed at 6 time points, up to 110 min after intravenous administration of 302 ± 11 MBq of BAY 864367. Imaging results were compared with (18)F-fluorocholine PET/CT scans. Dosimetry was calculated using the OLINDA/EXM software. Three of 5 patients with primary disease showed positive tumor delineation in the prostate, and 2 of 5 patients with biochemical relapse showed a lesion suggestive of recurrence on the BAY 864367 scan. Tumor-to-background ratio averaged 12.9 ± 7.0. The ratio of malignant prostate tissue to normal prostate tissue was 4.4 ± 0.6 in 3 patients with tracer uptake in the primary PCa. Mean effective dose was 4.3 ± 0.3 mSv/patient (range, 3.7-4.9 mSv). BAY 864367, a novel (18)F-labeled bombesin tracer, was successfully investigated in a first-in-man clinical trial of PCa and showed favorable dosimetric values. Additionally, the application was safe and well tolerated. The tracer delineated tumors in a subset of patients, demonstrating the potential of gastrin-releasing-peptide receptor imaging. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  15. Pleuroperitoneal Mesothelioma: A Rare Entity on 18F-FDG PET/CT

    PubMed Central

    Sahoo, Manas Kumar; Mukherjee, Anirban; Girish; Parida, Kumar; Agarwal, Krishan Kant; Bal, Chandrasekhar; Tripathi, Madhavi; Das, Chandan Jyoti; Shamim, Shamim Ahmed

    2017-01-01

    Pleuroperitoneal mesothelioma is an extremely rare entity. Only few cases are reported worldwide. We hereby represent a case of pleural mesothelioma referred for F-18-Fluorodeoxyglucose positron emission tomography/computed tomography for response evaluation. Diffuse F-18-Fluorodeoxyglucose avid peritoneal and omental thickening noted which subsequently turned out to be mesothelial involvement on peritoneal biopsy. This case demonstrates the role of F-18-Fluorodeoxyglucose positron emission tomography/computed tomography in detecting other sites of involvement in case of malignant mesothelioma. PMID:28242997

  16. Optimization of 18 F-syntheses using 19 F-reagents at tracer-level concentrations and liquid chromatography/tandem mass spectrometry analysis: Improved synthesis of [18 F]MDL100907.

    PubMed

    Zhang, Xiang; Dunlow, Ryan; Blackman, Burchelle N; Swenson, Rolf E

    2018-05-15

    Traditional radiosynthetic optimization faces the challenges of high radiation exposure, cost, and inability to perform serial reactions due to tracer decay. To accelerate tracer development, we have developed a strategy to simulate radioactive 18 F-syntheses by using tracer-level (nanomolar) non-radioactive 19 F-reagents and LC-MS/MS analysis. The methodology was validated with fallypride synthesis under tracer-level 19 F-conditions, which showed reproducible and comparable results with radiosynthesis, and proved the feasibility of this process. Using this approach, the synthesis of [ 18 F]MDL100907 was optimized under 19 F-conditions with greatly improved yield. The best conditions were successfully transferred to radiosynthesis. A radiochemical yield of 19% to 22% was achieved with the radiochemical purity >99% and the molar activity 38.8 to 53.6 GBq/ μmol (n = 3). The tracer-level 19 F-approach provides a high-throughput and cost-effective process to optimize radiosynthesis with reduced radiation exposure. This new method allows medicinal and synthetic chemists to optimize radiolabeling conditions without the need to use radioactivity. Copyright © 2018 John Wiley & Sons, Ltd.

  17. Comparison of in vivo binding properties of the 18-kDa translocator protein (TSPO) ligands [(18)F]PBR102 and [ (18)F]PBR111 in a model of excitotoxin-induced neuroinflammation.

    PubMed

    Callaghan, P D; Wimberley, C A; Rahardjo, G L; Berghofer, P J; Pham, T Q; Jackson, T; Zahra, D; Bourdier, T; Wyatt, N; Greguric, I; Howell, N R; Siegele, R; Pastuovic, Z; Mattner, F; Loc'h, C; Gregoire, M C; Katsifis, A

    2015-01-01

    The in vivo binding parameters of the novel imidazopyridine TSPO ligand [(18)F]PBR102 were assessed and compared with those of [(18)F]PBR111 in a rodent model of neuroinflammation. The validity of the key assumptions of the simplified reference tissue model (SRTM) for estimation of binding potential (BP) was determined, with validation against a two-tissue compartment model (2TC). Acute neuroinflammation was assessed 7 days after unilateral stereotaxic administration of (R,S)-α-amino-3-hydroxy-5-methyl-4-isoxazolopropionique (AMPA) in anaesthetized adult Wistar rats. Anaesthetized rats were implanted with a femoral arterial cannula then injected with a low mass of [(18)F]PBR102 or [(18)F]PBR111 and dynamic images were acquired over 60 min using an INVEON PET/CT camera. Another population of rats underwent the same PET protocol after pretreatment with a presaturating mass of the same unlabelled tracer (1 mg/kg) to assess the validity of the reference region for SRTM analysis. Arterial blood was sampled during imaging, allowing pharmacokinetic determination of radiotracer concentrations. Plasma activity concentration-time curves were corrected for unchanged tracer based on metabolic characterization experiments in a separate cohort of Wistar rats. The stability of neuroinflammation in both imaging cohorts was assessed by [(125)I] CLINDE TSPO quantitative autoradiography, OX42/GFAP immunohistochemistry, Fluoro-Jade C histology, and elemental mapping using microparticle-induced x-ray emission spectroscopy. The BP of each ligand were assessed in the two cohorts of lesioned animals using both SRTM and a 2TC with arterial parent compound concentration, coupled with the results from the presaturation cohort for comparison and validation of the SRTM. The BPs of [(18)F]PBR102 [(18)F]PBR111 were equivalent, with improved signal-to-noise ratio and sensitivity compared with [(11)C]PK11195. The presaturation study showed differences in the volume of distribution between the

  18. Single-scan rest/stress imaging: validation in a porcine model with 18F-Flurpiridaz.

    PubMed

    Guehl, Nicolas J; Normandin, Marc D; Wooten, Dustin W; Rozen, Guy; Sitek, Arkadiusk; Ruskin, Jeremy; Shoup, Timothy M; Ptaszek, Leon M; El Fakhri, Georges; Alpert, Nathaniel M

    2017-08-01

    18 F-labeled myocardial flow agents are becoming available for clinical application but the ∼2 hour half-life of 18 F complicates their clinical application for rest-stress measurements. The goal of this work is to evaluate in a pig model a single-scan method which provides quantitative rest-stress blood flow in less than 15 minutes. Single-scan rest-stress measurements were made using 18 F-Flurpiridaz. Nine scans were performed in healthy pigs and seven scans were performed in injured pigs. A two-injection, single-scan protocol was used in which an adenosine infusion was started 4 minutes after the first injection of 18 F-Flurpiridaz and followed either 3 or 6 minutes later by a second radiotracer injection. In two pigs, microsphere flow measurements were made at rest and during stress. Dynamic images were reoriented into the short axis view, and regions of interest (ROIs) for the 17 myocardial segments were defined in bull's eye fashion. PET data were fitted with MGH2, a kinetic model with time varying kinetic parameters, in which blood flow changes abruptly with the introduction of adenosine. Rest and stress myocardial blood flow (MBF) were estimated simultaneously. The first 12-14 minutes of rest-stress PET data were fitted in detail by the MGH2 model, yielding MBF measurement with a mean precision of 0.035 ml/min/cc. Mean myocardial blood flow across pigs was 0.61 ± 0.11 mL/min/cc at rest and 1.06 ± 0.19 mL/min/cc at stress in healthy pigs and 0.36 ± 0.20 mL/min/cc at rest and 0.62 ± 0.24 mL/min/cc at stress in the ischemic area. Good agreement was obtained with microsphere flow measurement (slope = 1.061 ± 0.017, intercept = 0.051 ± 0.017, mean difference 0.096 ± 0.18 ml/min/cc). Accurate rest and stress blood flow estimation can be obtained in less than 15 min of PET acquisition. The method is practical and easy to implement suggesting the possibility of clinical translation.

  19. Quantitative analysis of 18F-NaF dynamic PET/CT cannot differentiate malignant from benign lesions in multiple myeloma

    PubMed Central

    Sachpekidis, Christos; Hillengass, Jens; Goldschmidt, Hartmut; Anwar, Hoda; Haberkorn, Uwe; Dimitrakopoulou-Strauss, Antonia

    2017-01-01

    A renewed interest has been recently developed for the highly sensitive bone-seeking radiopharmaceutical 18F-NaF. Aim of the present study is to evaluate the potential utility of quantitative analysis of 18F-NaF dynamic PET/CT data in differentiating malignant from benign degenerative lesions in multiple myeloma (MM). 80 MM patients underwent whole-body PET/CT and dynamic PET/CT scanning of the pelvis with 18F-NaF. PET/CT data evaluation was based on visual (qualitative) assessment, semi-quantitative (SUV) calculations, and absolute quantitative estimations after application of a 2-tissue compartment model and a non-compartmental approach leading to the extraction of fractal dimension (FD). In total 263 MM lesions were demonstrated on 18F-NaF PET/CT. Semi-quantitative and quantitative evaluations were performed for 25 MM lesions as well as for 25 benign, degenerative and traumatic lesions. Mean SUVaverage for MM lesions was 11.9 and mean SUVmax was 23.2. Respectively, SUVaverage and SUVmax for degenerative lesions were 13.5 and 20.2. Kinetic analysis of 18F-NaF revealed the following mean values for MM lesions: K1 = 0.248 (1/min), k3 = 0.359 (1/min), influx (Ki) = 0.107 (1/min), FD = 1.382, while the respective values for degenerative lesions were: K1 = 0.169 (1/min), k3 = 0.422 (1/min), influx (Ki) = 0.095 (1/min), FD = 1. 411. No statistically significant differences between MM and benign degenerative disease regarding SUVaverage, SUVmax, K1, k3 and influx (Ki) were demonstrated. FD was significantly higher in degenerative than in malignant lesions. The present findings show that quantitative analysis of 18F-NaF PET data cannot differentiate malignant from benign degenerative lesions in MM patients, supporting previously published results, which reflect the limited role of 18F-NaF PET/CT in the diagnostic workup of MM. PMID:28913153

  20. Quantitative analysis of 18F-NaF dynamic PET/CT cannot differentiate malignant from benign lesions in multiple myeloma.

    PubMed

    Sachpekidis, Christos; Hillengass, Jens; Goldschmidt, Hartmut; Anwar, Hoda; Haberkorn, Uwe; Dimitrakopoulou-Strauss, Antonia

    2017-01-01

    A renewed interest has been recently developed for the highly sensitive bone-seeking radiopharmaceutical 18 F-NaF. Aim of the present study is to evaluate the potential utility of quantitative analysis of 18 F-NaF dynamic PET/CT data in differentiating malignant from benign degenerative lesions in multiple myeloma (MM). 80 MM patients underwent whole-body PET/CT and dynamic PET/CT scanning of the pelvis with 18 F-NaF. PET/CT data evaluation was based on visual (qualitative) assessment, semi-quantitative (SUV) calculations, and absolute quantitative estimations after application of a 2-tissue compartment model and a non-compartmental approach leading to the extraction of fractal dimension (FD). In total 263 MM lesions were demonstrated on 18 F-NaF PET/CT. Semi-quantitative and quantitative evaluations were performed for 25 MM lesions as well as for 25 benign, degenerative and traumatic lesions. Mean SUV average for MM lesions was 11.9 and mean SUV max was 23.2. Respectively, SUV average and SUV max for degenerative lesions were 13.5 and 20.2. Kinetic analysis of 18 F-NaF revealed the following mean values for MM lesions: K 1 = 0.248 (1/min), k 3 = 0.359 (1/min), influx (K i ) = 0.107 (1/min), FD = 1.382, while the respective values for degenerative lesions were: K 1 = 0.169 (1/min), k 3 = 0.422 (1/min), influx (K i ) = 0.095 (1/min), FD = 1. 411. No statistically significant differences between MM and benign degenerative disease regarding SUV average , SUV max , K 1 , k 3 and influx (K i ) were demonstrated. FD was significantly higher in degenerative than in malignant lesions. The present findings show that quantitative analysis of 18 F-NaF PET data cannot differentiate malignant from benign degenerative lesions in MM patients, supporting previously published results, which reflect the limited role of 18 F-NaF PET/CT in the diagnostic workup of MM.

  1. Robust surface coating for a fast, facile fluorine-18 labeling of iron oxide nanoparticles for PET/MR dual-modality imaging

    DOE PAGES

    Sun, Ziyan; Cheng, Kai; Wu, Fengyu; ...

    2016-10-31

    Grafting a robust organic shell around inorganic nanoparticles can optimize their colloidal features to dramatically improve their physicochemical properties. Here, we have developed a polymer coating procedure for providing colloidal stability to the nanoparticles and, more importantly, for applying a fast, facile fluorine-18 labeling of iron oxide nanoparticles (IONPs) for positron emission tomography (PET)/magnetic resonance (MR) dual-modality imaging. The structure of the amphiphilic polymer is based on a backbone of polyacrylic acid, conjugated with multiple oleylamines to form a comb-like branched structure. The dense polymer shell provides high colloidal stability to the IONPs against harsh conditions such as high temperature,more » low pH value, and high ion strength. By incorporating a 1,4,7-triazacyclononane (NOTA) chelator to the comb-like amphiphilic polymer for the chelation of aluminum fluoride ions, we applied a one-step radiolabeling approach for a fast, facile radiofluorination of magnetic nanoparticles. The new strategy can significantly reduce the procedure time and radiation exposure. In conclusion, the PET/MR dual modality imaging was successfully achieved in living subjects by using 18F labeled magnetic nanoparticles.« less

  2. Robust surface coating for a fast, facile fluorine-18 labeling of iron oxide nanoparticles for PET/MR dual-modality imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sun, Ziyan; Cheng, Kai; Wu, Fengyu

    Grafting a robust organic shell around inorganic nanoparticles can optimize their colloidal features to dramatically improve their physicochemical properties. Here, we have developed a polymer coating procedure for providing colloidal stability to the nanoparticles and, more importantly, for applying a fast, facile fluorine-18 labeling of iron oxide nanoparticles (IONPs) for positron emission tomography (PET)/magnetic resonance (MR) dual-modality imaging. The structure of the amphiphilic polymer is based on a backbone of polyacrylic acid, conjugated with multiple oleylamines to form a comb-like branched structure. The dense polymer shell provides high colloidal stability to the IONPs against harsh conditions such as high temperature,more » low pH value, and high ion strength. By incorporating a 1,4,7-triazacyclononane (NOTA) chelator to the comb-like amphiphilic polymer for the chelation of aluminum fluoride ions, we applied a one-step radiolabeling approach for a fast, facile radiofluorination of magnetic nanoparticles. The new strategy can significantly reduce the procedure time and radiation exposure. In conclusion, the PET/MR dual modality imaging was successfully achieved in living subjects by using 18F labeled magnetic nanoparticles.« less

  3. F-18 choline PET does not detect increased metabolism in F-18 fluoroethyltyrosine-negative low-grade gliomas.

    PubMed

    Roelcke, Ulrich; Bruehlmeier, Matthias; Hefti, Martin; Hundsberger, Thomas; Nitzsche, Egbert U

    2012-01-01

    Positron emission tomography (PET) with radiolabeled amino acids provides information on biopsy target and chemotherapy response in patients with low-grade gliomas (LGG). In this article, we addressed whether PET with F-18 choline (CHO) detects increased metabolism in F-18 fluoroethyltyrosine (FET)-negative LGG patients. Six LGG patients with nongadolinium-enhancing (magnetic resonance) FET-negative LGG were imaged with CHO PET. Regions of interest were positioned over tumor and contralateral brain. Uptake of FET and CHO was quantified as count ratio of tumor to contralateral brain. The mean FET uptake ratio for FET-negative LGG was 0.95 ± 0.03 (mean ± standard deviation). Five tumors did not show increased uptake ratios for CHO (0.96 ± 0.12). Slightly increased CHO uptake was found in 1 patient (1.24), which, however, was not associated with tumor visualization. Amino acid and choline uptake appear to behave similar in nongadolinium-enhancing LGG. For clinical purposes, CHO PET is not superior to FET PET.

  4. Sodium 18F-Fluoride PET/CT of Bone, Joint and Other Disorders

    PubMed Central

    Jadvar, Hossein; Desai, Bhushan; Conti, Peter S.

    2014-01-01

    The use of 18F-sodium fluoride (18F-NaF) with positron emission tomography-computed tomography (PET/CT) is increasing. This resurgence of an old tracer has been fueled by several factors including superior diagnostic performance over standard 99mTc-based bone scintigraphy, growth in the availability of PET/CT imaging systems, increase in the number of regional commercial distribution centers for PET radiotracers, the recent concerns about potential chronic shortages with 99mTc based radiotracers, and the recent decision by the Centers for Medicare and Medicaid Services to reimburse for 18F-NaF PET/CT for evaluation of patients with known or suspected bone metastases through the National Oncologic PET Registry. The major goal of this article is to review the current evidence on the diagnostic utility of 18F-NaF in the imaging assessment of bone and joint in a variety of clinical conditions. PMID:25475379

  5. 18F-FEAnGA for PET of β-glucuronidase activity in neuroinflammation.

    PubMed

    Antunes, Inês F; Doorduin, Janine; Haisma, Hidde J; Elsinga, Philip H; van Waarde, Aren; Willemsen, Antoon T M; Dierckx, Rudi A; de Vries, Erik F J

    2012-03-01

    Activation of microglia is a hallmark of inflammatory, infectious, and degenerative diseases of the central nervous system. Several studies have indicated that there is an increase in release of β-glucuronidase by activated microglia into the extracellular space at the site of neuroinflammation. β-glucuronidase is involved in the hydrolysis of glycosaminoglycans on the cell surface and the degradation of the extracellular matrix. Therefore, β-glucuronidase might be a biomarker for ongoing neurodegeneration induced by neuroinflammation. In this study, we investigated whether the PET tracer (18)F-FEAnGA was able to detect β-glucuronidase release during neuroinflammation in a rat model of herpes encephalitis. Male Wistar rats were intranasally inoculated with herpes simplex virus 1 (HSV-1) or phosphate-buffered saline as a control. (11)C-(R)-PK11195 and (18)F-FEAnGA small-animal PET scans were acquired for 60 min. Logan graphical analysis was used to calculate (18)F-FEAnGA distribution volumes (DV(Logan)) in various brain areas. After administration of (18)F-FEAnGA, the area under the activity concentration-versus-time curve of the whole brain was 2 times higher in HSV-1-infected rats than in control rats. In addition, the DV(Logan) of (18)F-FEAnGA was most increased in the frontopolar cortex, frontal cortex, bulbus olfactorius, cerebral cortex, cerebellum, and brainstem of HSV-1-infected rats, when compared with control rats. The conversion of (18)F-FEAnGA to 4-hydroxy-3-nitrobenzyl alcohol was found to be 1.6 times higher in HSV-1-infected rats than in control rats and correlated with the DV(Logan) of (18)F-FEAnGA in the same areas of the brain. Furthermore, the DV(Logan) of (18)F-FEAnGA also correlated with β-glucuronidase activity in the same brain regions. In addition, DV(Logan) of (18)F-FEAnGA showed a tendency to correlate with (11)C-(R)-PK11195 uptake (marker for activated microglia) in the same brain regions. Despite relatively low brain uptake, (18)F

  6. Imaging Enterobacteriaceae infection in vivo with 18F-fluorodeoxysorbitol positron emission tomography

    PubMed Central

    Weinstein, Edward A.; Ordonez, Alvaro A.; DeMarco, Vincent P.; Murawski, Allison M.; Pokkali, Supriya; MacDonald, Elizabeth M.; Klunk, Mariah; Mease, Ronnie C.; Pomper, Martin G.; Jain, Sanjay K.

    2015-01-01

    The Enterobacteriaceae are a family of rod-shaped Gram-negative bacteria that normally inhabit the gastrointestinal tract and are the most common cause of Gram-negative bacterial infections in humans. In addition to causing serious multidrug-resistant, hospital-acquired infections, a number of Enterobacteriaceae species are also recognized as biothreat pathogens. As a consequence, new tools are urgently needed to specifically identify and localize infections due to Enterobacteriaceae and to monitor antimicrobial efficacy. In this report, we used commercially available 2-[18F]-fluorodeoxyglucose (18F-FDG) to produce 2-[18F]-fluorodeoxysorbitol (18F-FDS), a radioactive probe for Enterobacteriaceae, in 30 min. 18F-FDS selectively accumulated in Enterobacteriaceae, but not in Gram-positive bacteria or healthy mammalian or cancer cells in vitro. In a murine myositis model, 18F-FDS positron emission tomography (PET) rapidly differentiated true infection from sterile inflammation with a limit of detection of 6.2 ± 0.2 log10 colony-forming units (CFU) for Escherichia coli. Our findings were extended to models of mixed Gram-positive and Gram-negative thigh co-infections, brain infection, Klebsiella pneumonia, and mice undergoing immunosuppressive chemotherapy. This technique rapidly and specifically localized infections due to Enterobacteriaceae, providing a three-dimensional holistic view within the animal. Last, 18F-FDS PET monitored the efficacy of antimicrobial treatment, demonstrating a PET signal proportionate to the bacterial burden. Therapeutic failures associated with multidrug-resistant, extended-spectrum β-lactamase (ESBL)–producing E. coli infections were detected in real time. Together, these data show that 18F-FDS is a candidate imaging probe for translation to human clinical cases of known or suspected infections owing to Enterobacteriaceae. PMID:25338757

  7. A quantitative analysis of the F18 flight control system

    NASA Technical Reports Server (NTRS)

    Doyle, Stacy A.; Dugan, Joanne B.; Patterson-Hine, Ann

    1993-01-01

    This paper presents an informal quantitative analysis of the F18 flight control system (FCS). The analysis technique combines a coverage model with a fault tree model. To demonstrate the method's extensive capabilities, we replace the fault tree with a digraph model of the F18 FCS, the only model available to us. The substitution shows that while digraphs have primarily been used for qualitative analysis, they can also be used for quantitative analysis. Based on our assumptions and the particular failure rates assigned to the F18 FCS components, we show that coverage does have a significant effect on the system's reliability and thus it is important to include coverage in the reliability analysis.

  8. Association of In Vivo [18F]AV-1451 Tau PET Imaging Results With Cortical Atrophy and Symptoms in Typical and Atypical Alzheimer Disease.

    PubMed

    Xia, Chenjie; Makaretz, Sara J; Caso, Christina; McGinnis, Scott; Gomperts, Stephen N; Sepulcre, Jorge; Gomez-Isla, Teresa; Hyman, Bradley T; Schultz, Aaron; Vasdev, Neil; Johnson, Keith A; Dickerson, Bradford C

    2017-04-01

    Previous postmortem studies have long demonstrated that neurofibrillary tangles made of hyperphosphorylated tau proteins are closely associated with Alzheimer disease clinical phenotype and neurodegeneration pattern. Validating these associations in vivo will lead to new diagnostic tools for Alzheimer disease and better understanding of its neurobiology. To examine whether topographical distribution and severity of hyperphosphorylated tau pathologic findings measured by fluorine 18-labeled AV-1451 ([18F]AV-1451) positron emission tomographic (PET) imaging are linked with clinical phenotype and cortical atrophy in patients with Alzheimer disease. This observational case series, conducted from July 1, 2012, to July 30, 2015, in an outpatient referral center for patients with neurodegenerative diseases, included 6 patients: 3 with typical amnesic Alzheimer disease and 3 with atypical variants (posterior cortical atrophy, logopenic variant primary progressive aphasia, and corticobasal syndrome). Patients underwent [18F]AV-1451 PET imaging to measure tau burden, carbon 11-labeled Pittsburgh Compound B ([11C]PiB) PET imaging to measure amyloid burden, and structural magnetic resonance imaging to measure cortical thickness. Seventy-seven age-matched controls with normal cognitive function also underwent structural magnetic resonance imaging but not tau or amyloid PET imaging. Tau burden, amyloid burden, and cortical thickness. In all 6 patients (3 women and 3 men; mean age 61.8 years), the underlying clinical phenotype was associated with the regional distribution of the [18F]AV-1451 signal. Furthermore, within 68 cortical regions of interest measured from each patient, the magnitude of cortical atrophy was strongly correlated with the magnitude of [18F]AV-1451 binding (3 patients with amnesic Alzheimer disease, r = -0.82; P < .001; r = -0.70; P < .001; r = -0.58; P < .001; and 3 patients with nonamnesic Alzheimer disease, r = -0.51; P

  9. Binding of /sup 18/F by cell membranes and cell walls of Streptococcus mutans

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yotis, W.W.; Zeb, M.; McNulty, J.

    1983-07-01

    The binding of /sup 18/F to isolated cell membranes and cell walls of Streptococcus mutans GS-5 or other bacteria was assayed. The attachment of /sup 18/F to these cell envelopes proceeded slowly and reached equilibrium within 60 min. /sup 18/F binding was stimulated by Ca/sup 2 +/ (1 mM). The binding of /sup 18/F to cellular components was dependent upon the pH, as well as the amount of /sup 18/F and dose of the binder employed. The binding of /sup 18/F by cell walls prepared from fluoride-sensitive and fluoride-resistant cells of S. salivarius and S. mutans did not differ significantly.more » The pretreatment of cell walls or cell membranes for 60 min at 30 degrees C with 1 mg of RNase, DNase, or trypsin per ml did not influence the binding of /sup 18/F by the walls and membranes of S. mutans GS-5. However, prior exposure of cell membranes to sodium dodecyl sulfate caused a significant reduction in the number of /sup 18/F atoms bound by the membranes. In saturated assay systems, cell membranes of S. mutans GS-5 bound 10(15) to 10(16) atoms of /sup 18/F per mg (dry weight), whereas cell walls from S. mutans GS-5, FA-1, and HS-6 or Actinomyces viscosus T14V and T14AV bound 10(12) to 10(13) atoms of /sup 18/F per mg (dry weight). /sup 18/F in this quantity (10(12) to 10(13) atoms) cannot be detected with the fluoride electrode. The data provide, for the first time, a demonstration of /sup 18/F binding by cell membranes and walls of oral flora.« less

  10. F18 Life Support: APECS and EDOX Cockpit Integration

    NASA Technical Reports Server (NTRS)

    Herrick, Paul

    1998-01-01

    Two systems are currently being integrated into the F18 Hornet support aircraft at NASA Dryden Flight Research Center (DFRC). The first system is the Aircrew Personal Environmental Control System (APECS). The system is designed to increase aircrew performance by combating heat stress in the cockpit. The second system is the Extended Duration Oxygen System (EDOX). This system will provide additional redundancy and oxygen system duration to the F18 without extensive modification to the current system.

  11. F-18 HARV research pilot Dana Purifoy

    NASA Technical Reports Server (NTRS)

    1996-01-01

    Dana D. Purifoy is an aerospace research pilot at NASA's Dryden Flight Research Center, Edwards, California. He joined NASA in August 1994. Purifoy is a former Air Force test pilot who served as a project pilot in the joint NASA/Air Force X-29 Forward Swept Wing research program conducted at Dryden from 1984 to 1991. His most recent assignment in the Air Force was flying U-2 aircraft as a test pilot at Air Force Plant 42, Palmdale, CA. In addition to flying the X-29 at Dryden as an Air Force pilot, Purifoy also served as project pilot and joint test force director with the AFTI F-16 (Advanced Fighter Technology Integration/F-16) program, also located at Dryden. Before his assignments as project pilot on the X-29 and AFTI/F-16 aircraft, Purifoy was chief of the Academics Systems Branch at the Air Force Test Pilot School at Edwards. Prior to becoming a test pilot, he flew F-111 and F-16 aircraft in Great Britain and Germany. He has accumulated 3800 hours of flying time in his career. The final flight for the F-18 High Alpha Research Vehicle (HARV) took place at NASA Dryden on May 29, 1996. The highly modified F-18 airplane flew 383 flights over a nine year period and demonstrated concepts that greatly increase fighter maneuverability. Among concepts proven in the aircraft is the use of paddles to direct jet engine exhaust in cases of extreme altitudes where conventional control surfaces lose effectiveness. Another concept, developed by NASA Langley Research Center, is a deployable wing-like surface installed on the nose of the aircraft for increased right and left (yaw) control on nose-high flight angles.

  12. A novel approach to breast cancer diagnosis via PET imaging of microcalcifications using 18F-NaF

    PubMed Central

    Wilson, George H.; Gore, John C.; Yankeelov, Thomas E.; Barnes, Stephanie; Peterson, Todd E.; True, Jarrod M.; Shokouhi, Sepideh; McIntyre, J. Oliver.; Sanders, Melinda; Abramson, Vandana; Ngyuen, The-Quyen; Mahadevan-Jansen, Anita; Tantawy, Mohammed N.

    2015-01-01

    Rationale Current radiological methods for diagnosing breast cancer detect specific morphological features of solid tumors and/or any associated calcium deposits. These deposits originate from an early molecular microcalcification process which consists of two types: type 1 is calcium oxylate (CO) and type II is carbonated calcium hydroxyapetite (HAP). Type I microcalcifications are mainly associated with benign tumors while type II have been shown to be produced, internally, by malignant cells. No current non-invasive in vivo techniques are available for detecting intratumoral microcalcifications. Such a technique would have a significant impact on breast cancer diagnosis and prognosis in preclinical and clinical settings. 18F-NaF PET has been solely used for bone imaging by targeting the bone HAP. In this work, we provide preliminary evidence that 18F-NaF PET imaging can be used to detect breast cancer by targeting the HAP lattice within the tumor microenvironment with high specificity and soft-tissue contrast-to-background ratio, while delineating tumors from inflammation. METHODS Mice were injected with approximately 106 MDA-MB-231 cells subcutaneously and imaged with 18F-NaF PET/CT in a 120 min dynamic sequence when the tumors reached a size of ~250 mm3. Regions-of-interest (ROIs) were drawn around the tumor, muscle, and bone. The concentration of the radiotracer within those ROIs were compared to one another. For comparison to inflammation, rats with inflammatory paws were subjected to 18F-NaF PET imaging. RESULTS Tumor uptake of 18F− was significantly higher (p<0.05) than muscle uptake where the tumor-to-muscle ratio was ~3.5. The presence of type II microcalcification in the MDA-MB-231 cell line was confirmed histologically using alizarin red S and von Kossa staining as well as Raman microspectroscopy. No uptake of 18F− was observed in the rat inflamed tissue. Lack of HAP in the inflamed tissue was verified histologically. CONCLUSIONS This study

  13. Stability analysis of an F/A-18 E/F cable mount m odel

    NASA Technical Reports Server (NTRS)

    Thompson, Nancy; Farmer, Moses

    1994-01-01

    A full-span F/A-18 E/F cable mounted wind tunnel model is part of a flutter clearance program at the NASA Langley Transonic Dynamics Tunnel. Parametric analysis of this model using GRUMCBL software was conducted to assess stability for wind tunnel tests. Two configurations of the F/A-18 E/F were examined. The parameters examined were pulley-cable friction, mach number, dynamic pressure, cable geometry, center of gravity location, cable tension, snubbing the model, drag, and test medium. For the nominal cable geometry (Cable Geometry 1), Configuration One was unstable for cases with higher pulley-cable friction coefficients. A new cable geometry (Cable Geometry 3) was determined in which Configuration One was stable for all cases evaluated. Configuration Two with the nominal center of gravity position was found to be unstable for cases with higher pulley-cable friction coefficients; however, the model was stable when the center of gravity moved forward 1/2. The model was tested using the cable mount system during the initial wind tunnel entry and was stable as predicted.

  14. Preclinical Evaluation of 18F-PSMA-1007, a New Prostate-Specific Membrane Antigen Ligand for Prostate Cancer Imaging.

    PubMed

    Cardinale, Jens; Schäfer, Martin; Benešová, Martina; Bauder-Wüst, Ulrike; Leotta, Karin; Eder, Matthias; Neels, Oliver C; Haberkorn, Uwe; Giesel, Frederik L; Kopka, Klaus

    2017-03-01

    In recent years, several radiotracers targeting the prostate-specific membrane antigen (PSMA) have been introduced. Some of them have had a high clinical impact on the treatment of patients with prostate cancer. However, the number of 18 F-labeled tracers addressing PSMA is still limited. Therefore, we aimed to develop a radiofluorinated molecule resembling the structure of therapeutic PSMA-617. Methods: The nonradioactive reference compound PSMA-1007 and the precursor were produced by solid-phase chemistry. The radioligand 18 F-PSMA-1007 was produced by a 2-step procedure with the prosthetic group 6- 18 F-fluoronicotinic acid 2,3,5,6-tetrafluorophenyl ester. The binding affinity of the ligand for PSMA and its internalization properties were evaluated in vitro with PSMA-positive LNCaP (lymph node carcinoma of the prostate) cells. Further, organ distribution studies were performed with mice bearing LNCaP and PC-3 (prostate cancer cell line; PSMA-negative) tumors. Finally, small-animal PET imaging of an LNCaP tumor-bearing mouse was performed. Results: The identified ligand had a binding affinity of 6.7 ± 1.7 nM for PSMA and an exceptionally high internalization ratio (67% ± 13%) in vitro. In organ distribution studies, high and specific tumor uptake (8.0 ± 2.4 percentage injected dose per gram) in LNCaP tumor-bearing mice was observed. In the small-animal PET experiments, LNCaP tumors were clearly visualized. Conclusion: The radiofluorinated PSMA ligand showed promising characteristics in its preclinical evaluation, and the feasibility of prostate cancer imaging was demonstrated by small-animal PET studies. Therefore, we recommend clinical transfer of the radioligand 18 F-PSMA-1007 for use as a diagnostic PET tracer in prestaging and monitoring of prostate cancer. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  15. Biodistribution and predictive value of 18F-fluorocyclophosphamide in mice bearing human breast cancer xenografts.

    PubMed

    Kesner, Amanda L; Hsueh, Wei-Ann; Htet, Nwe Linn; Pio, Betty S; Czernin, Johannes; Pegram, Mark D; Phelps, Michael E; Silverman, Daniel H S

    2007-12-01

    In mice bearing human breast cancer xenografts, we examined the biodistribution of (18)F-fluorocyclophosphamide ((18)F-F-CP) to evaluate its potential as a noninvasive prognostic tool for predicting the resistance of tumors to cyclophosphamide therapy. (18)F-F-CP was synthesized as we recently described, and PET data were acquired after administration of (18)F-F-CP in mice bearing human breast cancer xenografts (MCF-7 cells). Tracer biodistribution in reconstructed images was quantified by region-of-interest analysis. Distribution was also assessed by harvesting dissected organs, tumors, and blood, determining (18)F content in each tissue with a gamma-well counter. The mice were subsequently treated with cyclophosphamide, and tumor size was monitored for at least 3 wk after chemotherapy administration. The distribution of harvested activity correlated strongly with distribution observed in PET images. Target organs were related to routes of metabolism and excretion. (18)F-F-CP uptake was highest in kidneys, lowest in brain, and intermediate in tumors, as determined by both image-based and tissue-based measurements. (18)F-F-CP uptake was not inhibited by coadministration of an approximately x700 concentration of unlabeled cyclophosphamide. PET measures of (18)F-F-CP uptake in tumor predicted the magnitude of the response to subsequent administration of cyclophosphamide. Noninvasive assessment of (18)F-F-CP uptake using PET may potentially be helpful for predicting the response of breast tumors to cyclophosphamide before therapy begins.

  16. The influence of interpreters' professional background and experience on the interpretation of multimodality imaging of pulmonary lesions using 18F-3'-deoxy-fluorothymidine and 18F-fluorodeoxyglucose PET/CT.

    PubMed

    Xu, Bai-xuan; Liu, Chang-bin; Wang, Rui-min; Shao, Ming-zhe; Fu, Li-ping; Li, Yun-gang; Tian, Jia-he

    2013-01-01

    Based on the results of a recently accomplished multicenter clinical trial for the incremental value of a dual-tracer (18F-FDG and 18F-FLT), dual-modality (PET and CT) imaging in the differential diagnosis of pulmonary lesions, we investigate some issues that might affect the image interpretation and result reporting. The images were read in two separate sessions. Firstly the images were read and reported by physician(s) of the imaging center on completion of each PET/CT scanning. By the end of MCCT, all images collected during the trial were re-read by a collective of readers in an isolated, blinded, and independent way. One hundred sixty two patients successfully passed the data verification and entered into the final analysis. The primary reporting result showed adding 18F-FDG image information did not change the clinical performance much in sensitivity, specifity and accuracy, but the ratio between SUVFLT and SUVFDG did help the differentiation efficacy among the three subgroups of patients. The collective reviewing result showed the diagnostic achievement varied with reading strategies. ANOVA indicated significant differences among (18)F-FDG, (18)F-FLT in SUV (F = 14.239, p = 0.004). CT had almost the same diagnostic performance as 18F-FLT. When the 18F-FDG, 18F-FLT and CT images read in pair, both diagnostic sensitivity and specificity improved. The best diagnostic figures were obtained in full-modality strategy, when dual-tracer PET worked in combination with CT. With certain experience and training both radiologists and nuclear physicians are qualified to read and to achieve the similar diagnostic accuracy in PET/CT study. Making full use of modality combination and selecting right criteria seems more practical than professional back ground and personal experience in the new hybrid imaging technology, at least when novel tracer or application is concerned.

  17. Comparison Study of Two Differently Clicked 18F-Folates—Lipophilicity Plays a Key Role

    PubMed Central

    Kettenbach, Kathrin; Reffert, Laura M.; Schieferstein, Hanno; Pektor, Stefanie; Eckert, Raphael; Miederer, Matthias; Rösch, Frank

    2018-01-01

    Within the last decade, several folate-based radiopharmaceuticals for Single Photon Emission Computed Tomography (SPECT) and Positron Emission Tomography (PET) have been evaluated; however, there is still a lack of suitable 18F-folates for clinical PET imaging. Herein, we report the synthesis and evaluation of two novel 18F-folates employing strain-promoted and copper-catalyzed click chemistry. Furthermore, the influence of both click-methods on lipophilicity and pharmacokinetics of the 18F-folates was investigated. 18F-Ala-folate and 18F-DBCO-folate were both stable in human serum albumin. In vitro studies proved their high affinity to the folate receptor (FR). The lipophilic character of the strain-promoted clicked 18F-DBCO-folate (logD = 0.6) contributed to a higher non-specific binding in cell internalization studies. In the following in vivo PET imaging studies, FR-positive tumors could not be visualized in a maximum intensity projection images. Compared with 18F-DBCO-folate, 18F-Ala-folate (logD = −1.4), synthesized by the copper-catalyzed click reaction, exhibited reduced lipophilicity, and as a result an improved in vivo performance and a clear-cut visualization of FR-positive tumors. In view of high radiochemical yield, radiochemical purity and favorable pharmacokinetics, 18F-Ala-folate is expected to be a promising candidate for FR-PET imaging. PMID:29562610

  18. [18F]-NaF PET/CT imaging in cardiac amyloidosis.

    PubMed

    Van Der Gucht, Axel; Galat, Arnault; Rosso, Jean; Guellich, Aziz; Garot, Jérôme; Bodez, Diane; Plante-Bordeneuve, Violaine; Hittinger, Luc; Dubois-Randé, Jean-Luc; Evangelista, Eva; Sasanelli, Myriam; Chalaye, Julia; Meignan, Michel; Itti, Emmanuel; Damy, Thibaud

    2016-08-01

    Cardiac amyloidosis (CA) is recognized as a common cause of restrictive cardiomyopathy and heart failure due to the deposition of insoluble proteins in the myocardial interstitium. We emphasize the role of [18F]-sodium fluoride (NaF) PET/CT as a potential noninvasive tool to identify and differentiate the transthyretin-related cardiac amyloidosis from the light-chain cardiac amyloidosis. We report cases of a 73-year-old man and a 75-year-old woman followed in our center for congestive heart failure with marked alteration of the left ventricular ejection fraction due to familial transthyretin Val122Ile cardiac amyloidosis and light-chain cardiac amyloidosis, respectively, confirmed on endomyocardial biopsy.

  19. (18)F-FACBC (anti1-amino-3-(18)F-fluorocyclobutane-1-carboxylic acid) versus (11)C-choline PET/CT in prostate cancer relapse: results of a prospective trial.

    PubMed

    Nanni, Cristina; Zanoni, Lucia; Pultrone, Cristian; Schiavina, Riccardo; Brunocilla, Eugenio; Lodi, Filippo; Malizia, Claudio; Ferrari, Matteo; Rigatti, Patrizio; Fonti, Cristina; Martorana, Giuseppe; Fanti, Stefano

    2016-08-01

    To compare the accuracy of (18)F-FACBC and (11)C-choline PET/CT in patients radically treated for prostate cancer presenting with biochemical relapse. This prospective study enrolled 100 consecutive patients radically treated for prostate cancer and presenting with rising PSA. Of these 100 patients, 89 were included in the analysis. All had biochemical relapse after radical prostatectomy (at least 3 months previously), had (11)C-choline and (18)F-FACBC PET/CT performed within 1 week and were off hormonal therapy at the time of the scans. The two tracers were compared directly in terms of overall positivity/negativity on both a per-patient basis and a per-site basis. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy were calculated for both the tracers; follow-up at 1 year (including correlative imaging, PSA trend and pathology when available) was considered as the standard of reference. In 51 patients the results were negative and in 25 patients positive with both the tracers, in eight patients the results were positive with (18)F-FACBC but negative with (11)C-choline, and in five patients the results were positive with (11)C-choline but negative with (18)F-FACBC. Overall in 49 patients the results were false-negative (FN), in two true-negative, in 24 true-positive (TP) and in none false-positive (FP) with both tracers. In terms of discordances between the tracers: (1) in one patient, the result was FN with (11)C-choline but FP with (18)F-FACBC (lymph node), (2) in seven, FN with (11)C-choline but TP with (18)F-FACBC (lymph node in five, bone in one, local relapse in one), (3) in one, FP with (11)C-choline (lymph node) but TP with (18)F-FACBC (local relapse), (4) in two, FP with (11)C-choline (lymph nodes in one, local relapse in one) but FN with (18)F-FACBC, and (5) in three, TP with (11)C-choline (lymph nodes in two, bone in one) but FN with (18)F-FACBC. With (11)C-choline and (18)F-FACBC, sensitivities

  20. Alanine and glycine conjugates of (2S,4R)-4-[18F]fluoroglutamine for tumor imaging.

    PubMed

    Zha, Zhihao; Ploessl, Karl; Lieberman, Brian P; Wang, Limin; Kung, Hank F

    2018-05-01

    Glutamine is an essential source of energy, metabolic substrates, and building block for supporting tumor proliferation. Previously, (2S,4R)-4-[ 18 F]fluoroglutamine (4F-Gln) was reported as a glutamine-related metabolic imaging agent. To improve the in vivo kinetics of this radiotracer, two new dipeptides, [ 18 F]Gly-(2S,4R)4-fluoroglutamine (Gly-4F-Gln) and [ 18 F]Ala-(2S,4R)4-fluoroglutamine (Ala-4F-Gln) were investigated. Radiolabeling was performed via 2-steps 18 F-fluorination. Cell uptake studies of Gly-4F-Gln and Ala-4F-Gln were investigated in 9 L cell lines. In vitro and in vivo metabolism studies were carried out in Fisher 344 rats. Biodistribution and microPET imaging studies were performed in 9 L tumor-bearing rats. In vitro incubation of these [ 18 F]dipeptides in rat and human blood showed a rapid conversion to (2S,4R)-4-[ 18 F]fluoroglutamine (t 1/2  = 2.3 and 0.2 min for [ 18 F]Gly-4F-Gln and [ 18 F]Ala-4F-Gln, respectively for human blood). Biodistribution and PET imaging in Fisher 344 rats bearing 9 L tumor xenografts showed that these dipeptides rapidly localized in the tumors, comparable to that of (2S,4R)-4-[ 18 F]fluoroglutamine (4F-Gln). The results support that these dipeptides, [ 18 F]Gly-4F-Gln and [ 18 F]Ala-4F-Gln, are prodrugs, which hydrolyze in the blood after an iv injection. They appear to be selectively taken up and trapped by tumor tissue in vivo. The dipeptide, [ 18 F]Ala-4F-Gln, may be suitable as a PET tracer for imaging glutaminolysis in tumors. Copyright © 2018 Elsevier Inc. All rights reserved.

  1. Disseminated Multi-system Sarcoidosis Mimicking Metastases on 18F-FDG PET/CT.

    PubMed

    Makis, William; Palayew, Mark; Rush, Christopher; Probst, Stephan

    2018-06-07

    A 60-year-old female with no significant medical history presented with hematuria. A computed tomography (CT) scan revealed extensive lymphadenopathy with hypodensities in the liver and spleen, and she was referred for an 18 F-fluorodeoxyglucose ( 18 F-FDG) positron emission tomography/CT (PET/CT) study to assess for malignancy of unknown primary. PET/CT revealed extensive 18 F-FDG avid lymphadenopathy as well as innumerable intensely 18 F-FDG avid lung, liver and splenic nodules, highly concerning for malignancy. A PET-guided bone marrow biopsy of the posterior superior iliac spine revealed several non-necrotizing, well-formed granulomas, consistent with sarcoidosis. The patient was managed conservatively and remained clinically well over the subsequent 9 years of follow-up.

  2. Quantification of 18F-Fluoride Kinetics: Evaluation of Simplified Methods.

    PubMed

    Raijmakers, Pieter; Temmerman, Olivier P P; Saridin, Carrol P; Heyligers, Ide C; Becking, Alfred G; van Lingen, Arthur; Lammertsma, Adriaan A

    2014-07-01

    (18)F-fluoride PET is a promising noninvasive method for measuring bone metabolism and bone blood flow. The purpose of this study was to assess the performance of various clinically useful simplified methods by comparing them with full kinetic analysis. In addition, the validity of deriving bone blood flow from K1 of (18)F-fluoride was investigated using (15)O-H2O as a reference. Twenty-two adults (mean age ± SD, 44.8 ± 25.2 y), including 16 patients scheduled for bone surgery and 6 healthy volunteers, were studied. All patients underwent dynamic (15)O-H2O and (18)F-fluoride scans before surgery. Ten of these patients had serial PET measurements before and at 2 time points after local bone surgery. During all PET scans, arterial blood was monitored continuously. (18)F-fluoride data were analyzed using nonlinear regression (NLR) and several simplified methods (Patlak and standardized uptake value [SUV]). SUV was evaluated for different time intervals after injection and after normalizing to body weight, lean body mass, and body surface area, and simplified measurements were compared with NLR results. In addition, changes in SUV and Patlak-derived fluoride influx rate (Ki) after surgery were compared with corresponding changes in NLR-derived Ki. Finally, (18)F-fluoride K1 was compared with bone blood flow derived from (15)O-H2O data, using the standard single-tissue-compartment model. K1 of (18)F-fluoride correlated with measured blood flow, but the correlation coefficient was relatively low (r = 0.35, P < 0.001). NLR resulted in a mean Ki of 0.0160 ± 0.0122, whereas Patlak analysis, for the interval 10-60 min after injection, resulted in an almost-identical mean Ki of 0.0161 ± 0.0117. The Patlak-derived Ki, for 10-60 min after injection, showed a high correlation with the NLR-derived Ki (r = 0.976). The highest correlation between Ki and lean body mass-normalized SUV was found for the interval 50-60 min (r = 0.958). Finally, changes in SUV correlated

  3. [18F]CFA as a clinically translatable probe for PET imaging of deoxycytidine kinase activity.

    PubMed

    Kim, Woosuk; Le, Thuc M; Wei, Liu; Poddar, Soumya; Bazzy, Jimmy; Wang, Xuemeng; Uong, Nhu T; Abt, Evan R; Capri, Joseph R; Austin, Wayne R; Van Valkenburgh, Juno S; Steele, Dalton; Gipson, Raymond M; Slavik, Roger; Cabebe, Anthony E; Taechariyakul, Thotsophon; Yaghoubi, Shahriar S; Lee, Jason T; Sadeghi, Saman; Lavie, Arnon; Faull, Kym F; Witte, Owen N; Donahue, Timothy R; Phelps, Michael E; Herschman, Harvey R; Herrmann, Ken; Czernin, Johannes; Radu, Caius G

    2016-04-12

    Deoxycytidine kinase (dCK), a rate-limiting enzyme in the cytosolic deoxyribonucleoside (dN) salvage pathway, is an important therapeutic and positron emission tomography (PET) imaging target in cancer. PET probes for dCK have been developed and are effective in mice but have suboptimal specificity and sensitivity in humans. To identify a more suitable probe for clinical dCK PET imaging, we compared the selectivity of two candidate compounds-[(18)F]Clofarabine; 2-chloro-2'-deoxy-2'-[(18)F]fluoro-9-β-d-arabinofuranosyl-adenine ([(18)F]CFA) and 2'-deoxy-2'-[(18)F]fluoro-9-β-d-arabinofuranosyl-guanine ([(18)F]F-AraG)-for dCK and deoxyguanosine kinase (dGK), a dCK-related mitochondrial enzyme. We demonstrate that, in the tracer concentration range used for PET imaging, [(18)F]CFA is primarily a substrate for dCK, with minimal cross-reactivity. In contrast, [(18)F]F-AraG is a better substrate for dGK than for dCK. [(18)F]CFA accumulation in leukemia cells correlated with dCK expression and was abrogated by treatment with a dCK inhibitor. Although [(18)F]CFA uptake was reduced by deoxycytidine (dC) competition, this inhibition required high dC concentrations present in murine, but not human, plasma. Expression of cytidine deaminase, a dC-catabolizing enzyme, in leukemia cells both in cell culture and in mice reduced the competition between dC and [(18)F]CFA, leading to increased dCK-dependent probe accumulation. First-in-human, to our knowledge, [(18)F]CFA PET/CT studies showed probe accumulation in tissues with high dCK expression: e.g., hematopoietic bone marrow and secondary lymphoid organs. The selectivity of [(18)F]CFA for dCK and its favorable biodistribution in humans justify further studies to validate [(18)F]CFA PET as a new cancer biomarker for treatment stratification and monitoring.

  4. [18F]CFA as a clinically translatable probe for PET imaging of deoxycytidine kinase activity

    PubMed Central

    Kim, Woosuk; Le, Thuc M.; Wei, Liu; Poddar, Soumya; Bazzy, Jimmy; Wang, Xuemeng; Uong, Nhu T.; Abt, Evan R.; Capri, Joseph R.; Austin, Wayne R.; Van Valkenburgh, Juno S.; Steele, Dalton; Gipson, Raymond M.; Slavik, Roger; Cabebe, Anthony E.; Taechariyakul, Thotsophon; Yaghoubi, Shahriar S.; Lee, Jason T.; Sadeghi, Saman; Lavie, Arnon; Faull, Kym F.; Witte, Owen N.; Donahue, Timothy R.; Phelps, Michael E.; Herschman, Harvey R.; Herrmann, Ken; Czernin, Johannes; Radu, Caius G.

    2016-01-01

    Deoxycytidine kinase (dCK), a rate-limiting enzyme in the cytosolic deoxyribonucleoside (dN) salvage pathway, is an important therapeutic and positron emission tomography (PET) imaging target in cancer. PET probes for dCK have been developed and are effective in mice but have suboptimal specificity and sensitivity in humans. To identify a more suitable probe for clinical dCK PET imaging, we compared the selectivity of two candidate compounds—[18F]Clofarabine; 2-chloro-2′-deoxy-2′-[18F]fluoro-9-β-d-arabinofuranosyl-adenine ([18F]CFA) and 2′-deoxy-2′-[18F]fluoro-9-β-d-arabinofuranosyl-guanine ([18F]F-AraG)—for dCK and deoxyguanosine kinase (dGK), a dCK-related mitochondrial enzyme. We demonstrate that, in the tracer concentration range used for PET imaging, [18F]CFA is primarily a substrate for dCK, with minimal cross-reactivity. In contrast, [18F]F-AraG is a better substrate for dGK than for dCK. [18F]CFA accumulation in leukemia cells correlated with dCK expression and was abrogated by treatment with a dCK inhibitor. Although [18F]CFA uptake was reduced by deoxycytidine (dC) competition, this inhibition required high dC concentrations present in murine, but not human, plasma. Expression of cytidine deaminase, a dC-catabolizing enzyme, in leukemia cells both in cell culture and in mice reduced the competition between dC and [18F]CFA, leading to increased dCK-dependent probe accumulation. First-in-human, to our knowledge, [18F]CFA PET/CT studies showed probe accumulation in tissues with high dCK expression: e.g., hematopoietic bone marrow and secondary lymphoid organs. The selectivity of [18F]CFA for dCK and its favorable biodistribution in humans justify further studies to validate [18F]CFA PET as a new cancer biomarker for treatment stratification and monitoring. PMID:27035974

  5. 18F-FDG avidity of pheochromocytomas and paragangliomas: a new molecular imaging signature?

    PubMed

    Taïeb, David; Sebag, Frederic; Barlier, Anne; Tessonnier, Laurent; Palazzo, Fausto F; Morange, Isabelle; Niccoli-Sire, Patricia; Fakhry, Nicolas; De Micco, Catherine; Cammilleri, Serge; Enjalbert, Alain; Henry, Jean-François; Mundler, Olivier

    2009-05-01

    Our objective was to evaluate (18)F-FDG PET uptake in patients with nonmetastatic and metastatic chromaffin-derived tumors. Twenty-eight consecutive unrelated patients with chromaffin tumors, including 9 patients with genetically determined disease, were studied. A combination of preoperative imaging work-up, surgical findings, and pathologic analyses was used to classify the patients into 2 groups: those with nonmetastatic disease (presumed benign, n = 18) and those with metastatic tumors (n = 10). (18)F-FDG PET was performed in all cases. Visual and quantitative analyses were individually graded for each tumor. Somatic mutations of the succinate dehydrogenase subunits B and D and Von-Hippel Lindau genes were also evaluated in 6 benign sporadic tumor samples. All but 2 patients showed significantly increased (18)F-FDG uptake on visual analysis. The maximum standardized uptake value (SUVmax) ranged from 1.9 to 42 (mean +/- SD, 8.2 +/- 9.7; median, 4.6) in nonmetastatic tumors and 2.3 to 29.3 (mean +/- SD, 9.7 +/- 8.4; median, 7.4) in metastatic tumors. No statistical difference was observed between the groups (P = 0.44), but succinate dehydrogenase-related tumors were notable in being the most (18)F-FDG-avid tumors (SUVmax, 42, 29.3, 21, 17, and 5.3). Succinate dehydrogenase and Von-Hippel Lindau-related tumors had a significantly higher SUVmax than did neurofibromatosis type 1 and multiple endocrine neoplasia type 2A syndrome-related tumors (P = 0.02). (18)F-FDG PET was superior to (131)I-metaiodobenzylguanidine in all metastatic patients but one. By contrast, (18)F-FDG PET underestimated the extent of the disease, compared with 6-(18)F-fluorodopa PET, in 5 patients with metastatic pheochromocytoma. However, succinate dehydrogenase mutations (germline and somatic) and functional dedifferentiation do not adequately explain (18)F-FDG uptake since most tumors were highly avid for (18)F-FDG. (18)F-FDG PET positivity is almost a constant feature of pheochromocytomas

  6. Optimization and quality assessment of the post-digestion 18O labeling based on urea for protein denaturation by HPLC/ESI-TOF mass spectrometry.

    PubMed

    Wang, Hongbin; Hu, Gaofei; Zhang, Yongqian; Yuan, Zheng; Zhao, Xuan; Zhu, Yong; Cai, De; Li, Yujuan; Xiao, Shengyuan; Deng, Yulin

    2010-07-15

    The post-digestion (18)O labeling method decouples protein digestion and peptide labeling. This method allows labeling conditions to be optimized separately and increases labeling efficiency. A common method for protein denaturation in proteomics is the use of urea. Though some previous studies have used urea-based protein denaturation before post-digestion (18)O labeling, the optimal (18)O labeling conditions in this case have not been yet reported. Present study investigated the effects of urea concentration and pH on the labeling efficiency and obtained an optimized protocol. It was demonstrated that urea inhibited (18)O incorporation depending on concentration. However, a urea concentration between 1 and 2M had minimal effects on labeling. It was also demonstrated that the use of FA to quench the digestion reaction severely affected the labeling efficiency. This study revealed the reason why previous studies gave different optimal pH for labeling. They neglect the effects of different digestion conditions on the labeling conditions. Excellent labeling quality was obtained at the optimized conditions using urea 1-2 M and pH 4.5, 98.4+/-1.9% for a standard protein mixture and 97.2+/-6.2% for a complex biological sample. For a 1:1 mixture analysis of the (16)O- and (18)O-labeled peptides from the same protein sample, the average abundance ratios reached 1.05+/-0.31, demonstrating a good quantitation quality at the optimized conditions. This work will benefit other researchers who pair urea-based protein denaturation with a post-digestion (18)O labeling method. 2010 Elsevier B.V. All rights reserved.

  7. Glycogen phosphorylase as a target for type 2 diabetes: synthetic, biochemical, structural and computational evaluation of novel N-acyl-N´-(β-D-glucopyranosyl) urea inhibitors.

    PubMed

    Kantsadi, Anastassia L; Parmenopoulou, Vanessa; Bakalov, Dimitar N; Snelgrove, Laura; Stravodimos, George A; Chatzileontiadou, Demetra S M; Manta, Stella; Panagiotopoulou, Angeliki; Hayes, Joseph M; Komiotis, Dimitri; Leonidas, Demetres D

    2015-01-01

    Glycogen phosphorylase (GP), a validated target for the development of anti-hyperglycaemic agents, has been targeted for the design of novel glycopyranosylamine inhibitors. Exploiting the two most potent inhibitors from our previous study of N-acyl-β-D-glucopyranosylamines (Parmenopoulou et al., Bioorg. Med. Chem. 2014, 22, 4810), we have extended the linking group to -NHCONHCO- between the glucose moiety and the aliphatic/aromatic substituent in the GP catalytic site β-cavity. The N-acyl-N´-(β-D-glucopyranosyl) urea inhibitors were synthesized and their efficiency assessed by biochemical methods, revealing inhibition constant values of 4.95 µM and 2.53 µM. Crystal structures of GP in complex with these inhibitors were determined and analyzed, providing data for further structure based design efforts. A novel Linear Response - Molecular Mechanics Coulomb Surface Area (LR-MM-CBSA) method has been developed which relates predicted and experimental binding free energies for a training set of N-acyl-N´-(β-D-glucopyranosyl) urea ligands with a correlation coefficient R(2) of 0.89 and leave-one-out cross-validation (LOO-cv) Q(2) statistic of 0.79. The method has significant applications to direct future lead optimization studies, where ligand entropy loss on binding is revealed as a key factor to be considered. ADMET property predictions revealed that apart from potential permeability issues, the synthesized N-acyl-N´-(β-D-glucopyranosyl) urea inhibitors have drug-like potential without any toxicity warnings.

  8. 18F-FLT PET/CT in the Evaluation of Pheochromocytomas and Paragangliomas: A Pilot Study.

    PubMed

    Blanchet, Elise M; Taieb, David; Millo, Corina; Martucci, Victoria; Chen, Clara C; Merino, Maria; Herscovitch, Peter; Pacak, Karel

    2015-12-01

    (18)F-FDG PET/CT has been proven to be a highly sensitive method for pheochromocytomas/paragangliomas (PHEOs/PGLs) associated with succinate dehydrogenase (SDH) mutations. This finding has been attributed to altered tumor cell metabolism resulting from these mutations and does not provide additional prognostic information to genotype. Therefore, identification of new biomarkers for aggressiveness is needed. A high Ki-67 index was proposed to be an additional prognostic factor. This pilot study aimed to evaluate 3'-deoxy-3'-(18)F-fluorothymidine ((18)F-FLT) PET/CT, a PET proliferation tracer, as a potential imaging agent in a series of 12 PHEO/PGL patients with different genetic backgrounds, to compare (18)F-FLT uptake with (18)F-FDG PET/CT, and to evaluate classic factors of aggressiveness. Twelve patients (7 metastatic and 5 nonmetastatic) were prospectively evaluated with (18)F-FDG and (18)F-FLT and followed for at least 2 y after the initial imaging work-up. Uptake was assessed at a lesion level, visually and quantitatively by maximum standardized uptake values (SUVmax) for both tracers. (18)F-FLT uptake was compared with risk factors known to be linked with a poor prognosis in PGLs (SDHB-mutated status, lesion size, dopaminergic phenotype) and with (18)F-FDG uptake. In 12 patients, 77 lesions were assessed. All lesions had low (18)F-FLT uptake (median SUVmax, 2.25; range, 0.7-4.5). There was no apparent superiority of (18)F-FLT uptake in progressive lesions, and most of the lesions showed a mismatch, with high (18)F-FDG uptake (median SUVmax, 10.8; range, 1.1-79.0) contrasting with low (18)F-FLT uptake. This study suggests that PHEOs/PGLs-even those that progress-do not exhibit intense (18)F-FLT uptake. It provides the first in vivo demonstration that proliferation may not be a major determinant of (18)F-FDG uptake in these tumors. These findings provide new insight into the biologic behavior of PGL and suggest that antiproliferative agents may be suboptimal

  9. HPLC and TLC methods for analysis of [18F]FDG and its metabolites from biological samples.

    PubMed

    Rokka, Johanna; Grönroos, Tove J; Viljanen, Tapio; Solin, Olof; Haaparanta-Solin, Merja

    2017-03-24

    The most used positron emission tomography (PET) tracer, 2-[ 18 F]fluoro-2-deoxy-d-glucose ([ 18 F]FDG), is a glucose analogue that is used to measure tissue glucose consumption. Traditionally, the Sokoloff model is the basis for [ 18 F]FDG modeling. According to this model, [ 18 F]FDG is expected to be trapped in a cell in the form of [ 18 F]FDG-6-phosphate ([ 18 F]FDG-6-P). However, several studies have shown that in tissues, [ 18 F]FDG metabolism goes beyond [ 18 F]FDG-6-P. Our aim was to develop radioHPLC and radioTLC methods for analysis of [ 18 F]FDG metabolites from tissue samples. The radioHPLC method uses a sensitive on-line scintillation detector to detect radioactivity, and the radioTLC method employs digital autoradiography to detect the radioactivity distribution on a TLC plate. The HPLC and TLC methods were developed using enzymatically in vitro-produced metabolites of [ 18 F]FDG as reference standards. For this purpose, three [ 18 F]FDG metabolites were synthesized: [ 18 F]FDG-6-P, [ 18 F]FD-PGL, and [ 18 F]FDG-1,6-P2. The two methods were evaluated by analyzing the [ 18 F]FDG metabolic profile from rodent ex vivo tissue homogenates. The HPLC method with an on-line scintillation detector had a wide linearity in a range of 5Bq-5kBq (LOD 46Bq, LOQ 139Bq) and a good resolution (Rs ≥1.9), and separated [ 18 F]FDG and its metabolites clearly. The TLC method combined with digital autoradiography had a high sensitivity in a wide range of radioactivity (0.1Bq-2kBq, LOD 0.24Bq, LOQ 0.31Bq), and multiple samples could be analyzed simultaneously. As our test and the method validation with ex vivo samples showed, both methods are useful, and at best they complement each other in analysis of [ 18 F]FDG and its radioactive metabolites from biological samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Utility of 18F-fluorodeoxy glucose and 18F-sodium fluoride positron emission tomography/computed tomography in the diagnosis of medication-related osteonecrosis of the jaw: A preclinical study in a rat model.

    PubMed

    Kim, Yemi; Lee, Ho-Young; Yoon, Hai-Jeon; Kim, Bom Sahn

    2016-04-01

    The aim of this study was to determine the clinical utility of positron emission tomography/computed tomography (PET/CT) using 18F-FDG and 18F-NaF for the diagnosis of osteonecrosis of the jaw (ONJ), by observing characteristics in rat models treated with zoledronic acid (ZA) and/or dexamethasone (DX) followed by tooth extraction. A total of 48 rats were divided randomly into four groups: Group 1, rats treated with ZA and DX; Group 2, rats treated with ZA; Group 3, rats treated with DX; and Group 4, rats treated with vehicle as normal controls. They underwent examinations with both 18F-FDG and 18F-NaF PET/CT at 4 weeks prior to tooth extraction (baseline) and 4 weeks after tooth extraction. Rats were then sacrificed to evaluate the histological incidence and characteristics of ONJ. Histological and radiological characteristics of all groups were compared to assess the effects of medication and tooth extraction. Baseline PET/CT studies using 18F-FDG and 18F-NaF showed no difference in uptake among the groups. However, 18F-FDG PET/CT performed at 4 weeks after tooth extraction showed increased glucose metabolism at the extraction site in both the ZA/DX and the ZA-only groups compared with that in the vehicle-treated group, in accordance with the higher incidence of histological ONJ (p < 0.05, respectively). 18F-NaF PET/CT performed at 4 weeks after tooth extraction showed decreased bone uptake in the extraction site in the ZA/DX, ZA, and DX groups versus the vehicle group (all p < 0.05), but this was not correlated with the incidence of histological ONJ. The incidence of ONJ was highest in the ZA/DX group (66.7%), followed by the ZA group, both of which were significantly higher than in the DX and vehicle groups (both p < 0.05). 18F-FDG PET/CT as an inflammatory marker appeared to be a more appropriate imaging modality than 18F-NaF PET/CT in diagnosing ONJ in a rat model including a ZA/DX group. However, the decreased bone remodeling tendency highlighted by 18F-NaF

  11. F-18 sodium fluoride PET/CT does not effectively image myocardial inflammation due to suspected cardiac sarcoidosis.

    PubMed

    Weinberg, Richard L; Morgenstern, Rachelle; DeLuca, Albert; Chen, Jennifer; Bokhari, Sabahat

    2017-12-01

    Sarcoidosis is an inflammatory disorder of unknown etiology that can involve the heart. While effective in imaging cardiac sarcoidosis, F-18 fluorodeoxyglucose (FDG) PET/CT often shows non-specific myocardial uptake. F-18 sodium fluoride (NaF) has been used to image inflammation in coronary artery plaques and has low background myocardial uptake. Here, we evaluated whether F-18 NaF can image myocardial inflammation due to clinically suspected cardiac sarcoidosis. We performed a single institution pilot study testing if F-18 NaF PET/CT can detect myocardial inflammation in patients with suspected cardiac sarcoidosis. Patients underwent cardiac PET/CT with F-18 FDG as part of their routine care and subsequently received an F-18 NaF PET/CT scan. Three patients underwent F-18 FDG and F-18 NaF imaging. In all patients, there was F-18 FDG uptake consistent with cardiac sarcoidosis. The F-18 NaF PET/CT scans showed no myocardial uptake. In this small preliminary study, PET/CT scan using F-18 NaF does not appear to detect myocardial inflammation caused by suspected cardiac sarcoidosis.

  12. The F-18 simulator at NASA's Dryden Flight Research Center, Edwards, California

    NASA Image and Video Library

    2004-10-04

    The F-18 simulator at NASA's Dryden Flight Research Center, Edwards, California. Simulators offer a safe and economical alternative to actual flights to gather data, as well as being excellent facilities for pilot practice and training. The F-18 Hornet is used primarily as a safety chase and mission support aircraft at NASA's Dryden Flight Research Center, Edwards, California. As support aircraft, the F-18's are used for safety chase, pilot proficiency, aerial photography and other mission support functions.

  13. [F-18]-AV-1451 binding correlates with postmortem neurofibrillary tangle Braak staging.

    PubMed

    Marquié, Marta; Siao Tick Chong, Michael; Antón-Fernández, Alejandro; Verwer, Eline E; Sáez-Calveras, Nil; Meltzer, Avery C; Ramanan, Prianca; Amaral, Ana C; Gonzalez, Jose; Normandin, Marc D; Frosch, Matthew P; Gómez-Isla, Teresa

    2017-10-01

    [F-18]-AV-1451, a PET tracer specifically developed to detect brain neurofibrillary tau pathology, has the potential to facilitate accurate diagnosis of Alzheimer's disease (AD), staging of brain tau burden and monitoring disease progression. Recent PET studies show that patients with mild cognitive impairment and AD dementia exhibit significantly higher in vivo [F-18]-AV-1451 retention than cognitively normal controls. Importantly, PET patterns of [F-18]-AV-1451 correlate well with disease severity and seem to match the predicted topographic Braak staging of neurofibrillary tangles (NFTs) in AD, although this awaits confirmation. We studied the correlation of autoradiographic binding patterns of [F-18]-AV-1451 and the stereotypical spatiotemporal pattern of progression of NFTs using legacy postmortem brain samples representing different Braak NFT stages (I-VI). We performed [F-18]-AV-1451 phosphor-screen autoradiography and quantitative tau measurements (stereologically based NFT counts and biochemical analysis of tau pathology) in three brain regions (entorhinal cortex, superior temporal sulcus and visual cortex) in a total of 22 cases: low Braak (I-II, n = 6), intermediate Braak (III-IV, n = 7) and high Braak (V-VI, n = 9). Strong and selective [F-18]-AV-1451 binding was detected in all tangle-containing regions matching precisely the observed pattern of PHF-tau immunostaining across the different Braak stages. As expected, no signal was detected in the white matter or other non-tangle containing regions. Quantification of [F-18]-AV-1451 binding was very significantly correlated with the number of NFTs present in each brain region and with the total tau and phospho-tau content as reported by Western blot and ELISA. [F-18]-AV-1451 is a promising biomarker for in vivo quantification of brain tau burden in AD. Neuroimaging-pathologic studies conducted on postmortem material from individuals imaged while alive are now needed to confirm these observations.

  14. Preclinical evaluation of the anti-tumor effects of the natural isoflavone genistein in two xenograft mouse models monitored by [18F]FDG, [18F]FLT, and [64Cu]NODAGA-cetuximab small animal PET.

    PubMed

    Honndorf, Valerie S; Wiehr, Stefan; Rolle, Anna-Maria; Schmitt, Julia; Kreft, Luisa; Quintanilla-Martinez, Letitia; Kohlhofer, Ursula; Reischl, Gerald; Maurer, Andreas; Boldt, Karsten; Schwarz, Michael; Schmidt, Holger; Pichler, Bernd J

    2016-05-10

    The natural phytoestrogen genistein is known as protein kinase inhibitor and tumor suppressor in various types of cancers. We studied its antitumor effect in two different xenograft models using positron emission tomography (PET) in vivo combined with ex vivo histology and nuclear magnetic resonance (NMR) metabolic fingerprinting. A431 and Colo205 tumor-bearing mice were treated with vehicle or genistein (500 mg/kg/d) over a period of 12 days. Imaging was performed with 2-deoxy-2-[18F]fluoro-D-glucose ([18F]FDG) and 3'-deoxy-3'-[18F]fluorothymidine ([18F] FLT). In a second study A431 tumor-bearing mice were treated with vehicle, genistein (500 mg/kg/d), cetuximab (1 mg/3d) or a combination of the compounds and imaged using [18F]FDG, [18F]FLT and [64Cu]NODAGA-cetuximab. Data were compared to histology and principal components analysis (PCA) of NMR fingerprinting data. Genistein reduced tumor growth significantly in both xenografts. [18F] FLT uptake was consistent in both models and corresponded to histological findings and also PCA whereas [18F]FDG and [64Cu]NODAGA-cetuximab were not suitable for therapy monitoring. As mono-therapy the natural isoflavone genistein has a powerful therapeutic effect in vivo on A431 and Colo205 tumors. [18F]FLT has superior consistency compared to the other tested tracers in therapy monitoring, while the treatment effect could be shown on the molecular level by histology and metabolic fingerprinting.

  15. Does Delayed-Time-Point Imaging Improve 18F-FDG-PET in Patients With MALT Lymphoma?

    PubMed Central

    Mayerhoefer, Marius E.; Giraudo, Chiara; Senn, Daniela; Hartenbach, Markus; Weber, Michael; Rausch, Ivo; Kiesewetter, Barbara; Herold, Christian J.; Hacker, Marcus; Pones, Matthias; Simonitsch-Klupp, Ingrid; Müllauer, Leonhard; Dolak, Werner; Lukas, Julius; Raderer, Markus

    2016-01-01

    Purpose To determine whether in patients with extranodal marginal zone B-cell lymphoma of the mucosa-associated lymphoid tissue lymphoma (MALT), delayed–time-point 2-18F-fluoro-2-deoxy-d-glucose-positron emission tomography (18F-FDG-PET) performs better than standard–time-point 18F-FDG-PET. Materials and Methods Patients with untreated histologically verified MALT lymphoma, who were undergoing pretherapeutic 18F-FDG-PET/computed tomography (CT) and consecutive 18F-FDG-PET/magnetic resonance imaging (MRI), using a single 18F-FDG injection, in the course of a larger-scale prospective trial, were included. Region-based sensitivity and specificity, and patient-based sensitivity of the respective 18F-FDG-PET scans at time points 1 (45–60 minutes after tracer injection, TP1) and 2 (100–150 minutes after tracer injection, TP2), relative to the reference standard, were calculated. Lesion-to-liver and lesion-to-blood SUVmax (maximum standardized uptake values) ratios were also assessed. Results 18F-FDG-PET at TP1 was true positive in 15 o f 23 involved regions, and 18F-FDG-PET at TP2 was true-positive in 20 of 23 involved regions; no false-positive regions were noted. Accordingly, region-based sensitivities and specificities were 65.2% (confidence interval [CI], 45.73%–84.67%) and 100% (CI, 100%-100%) for 18F-FDG-PET at TP1; and 87.0% (CI, 73.26%–100%) and 100% (CI, 100%-100%) for 18F-FDG-PET at TP2, respectively. FDG-PET at TP1 detected lymphoma in at least one nodal or extranodal region in 7 of 13 patients, and 18F-FDG-PET at TP2 in 10 of 13 patients; accordingly, patient-based sensitivity was 53.8% (CI, 26.7%–80.9%) for 18F-FDG-PET at TP1, and 76.9% (CI, 54.0%–99.8%) for 18F-FDG-PET at TP2. Lesion-to-liver and lesion-to-blood maximum standardized uptake value ratios were significantly lower at TP1 (ratios, 1.05 ± 0.40 and 1.52 ± 0.62) than at TP2 (ratios, 1.67 ± 0.74 and 2.56 ± 1.10; P = 0.003 and P = 0.001). Conclusions Delayed–time-point imaging

  16. In Vivo MR Imaging of Glioma Recruitment of Adoptive T-Cells Labeled with NaGdF4 -TAT Nanoprobes.

    PubMed

    Zhang, Hua; Wu, Yue; Wang, Jing; Tang, Zhongmin; Ren, Yan; Ni, Dalong; Gao, Hongbo; Song, Ruixue; Jin, Teng; Li, Qiao; Bu, Wenbo; Yao, Zhenwei

    2018-01-01

    Adoptive T lymphocyte immunotherapy is one of the most promising methods to treat residual lesions after glioma surgery. However, the fate of the adoptively transferred T-cells in vivo is unclear, hampering the understanding of this emerging therapy. Thus, it is highly desirable to develop noninvasive and quantitative in vivo tracking of these T-cells to glioma for better identification of the migratory fate and to provide objective evaluation of outcomes of adoptive T-cell immunotherapy targeting glioma. In this work, ultrasmall T 1 MR-based nanoprobes, NaGdF 4 -TAT, as molecular probes with high longitudinal relaxivity (8.93 mm -1 s -1 ) are designed. By means of HIV-1 transactivator (TAT) peptides, nearly 95% of the adoptive T-cells are labeled with the NaGdF 4 -TAT nanoprobes without any measurable side effects on the labeled T-cells, which is remarkably superior to that of the control fluorescein isothiocyanate-NaGdF 4 concerning labeling efficacy. Labeled adoptive T-cell clusters can be sensitively tracked in an orthotopic GL261-glioma model 24 h after intravenous infusion of 10 7 labeled T-cells by T 1 -weighted MR imaging. Both in vitro and in vivo experiments show that the NaGdF 4 -TAT nanoprobes labeling of T-cells may be a promising method to track adoptive T-cells to improve our understanding of the pathophysiology in adoptive immunotherapy for gliomas. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Normal bone and soft tissue distribution of fluorine-18-sodium fluoride and artifacts on 18F-NaF PET/CT bone scan: a pictorial review.

    PubMed

    Sarikaya, Ismet; Elgazzar, Abdelhamid H; Sarikaya, Ali; Alfeeli, Mahmoud

    2017-10-01

    Fluorine-18-sodium fluoride (F-NaF) PET/CT is a relatively new and high-resolution bone imaging modality. Since the use of F-NaF PET/CT has been increasing, it is important to accurately assess the images and be aware of normal distribution and major artifacts. In this pictorial review article, we will describe the normal uptake patterns of F-NaF in the bone tissues, particularly in complex structures, as well as its physiologic soft tissue distribution and certain artifacts seen on F-NaF PET/CT images.

  18. Distinct [18F]THK5351 binding patterns in primary progressive aphasia variants.

    PubMed

    Schaeverbeke, Jolien; Evenepoel, Charlotte; Declercq, Lieven; Gabel, Silvy; Meersmans, Karen; Bruffaerts, Rose; Adamczuk, Kate; Dries, Eva; Van Bouwel, Karen; Sieben, Anne; Pijnenburg, Yolande; Peeters, Ronald; Bormans, Guy; Van Laere, Koen; Koole, Michel; Dupont, Patrick; Vandenberghe, Rik

    2018-06-26

    To assess the binding of the PET tracer [ 18 F]THK5351 in patients with different primary progressive aphasia (PPA) variants and its correlation with clinical deficits. The majority of patients with nonfluent variant (NFV) and logopenic variant (LV) PPA have underlying tauopathy of the frontotemporal lobar or Alzheimer disease type, respectively, while patients with the semantic variant (SV) have predominantly transactive response DNA binding protein 43-kDa pathology. The study included 20 PPA patients consecutively recruited through a memory clinic (12 NFV, 5 SV, 3 LV), and 20 healthy controls. All participants received an extensive neurolinguistic assessment, magnetic resonance imaging and amyloid biomarker tests. [ 18 F]THK5351 binding patterns were assessed on standardized uptake value ratio (SUVR) images with the cerebellar grey matter as the reference using statistical parametric mapping. Whole-brain voxel-wise regression analysis was performed to evaluate the association between [ 18 F]THK5351 SUVR images and neurolinguistic scores. Analyses were performed with and without partial volume correction. Patients with NFV showed increased binding in the supplementary motor area, left premotor cortex, thalamus, basal ganglia and midbrain compared with controls and patients with SV. Patients with SV had increased binding in the temporal lobes bilaterally and in the right ventromedial frontal cortex compared with controls and patients with NFV. The whole-brain voxel-wise regression analysis revealed a correlation between agrammatism and motor speech impairment, and [ 18 F]THK5351 binding in the left supplementary motor area and left postcentral gyrus. Analysis of [ 18 F]THK5351 scans without partial volume correction revealed similar results. [ 18 F]THK5351 imaging shows a topography closely matching the anatomical distribution of predicted underlying pathology characteristic of NFV and SV PPA. [ 18 F]THK5351 binding correlates with the severity of clinical

  19. Design of CGMP Production of 18F- and 68Ga-Radiopharmaceuticals

    PubMed Central

    Chu, Pei-Chun; Chao, Hao-Yu; Shieh, Wei-Chen; Chen, Chuck C.

    2014-01-01

    Objective. Radiopharmaceutical production process must adhere to current good manufacturing process (CGMP) compliance to ensure the quality of precursor, prodrug (active pharmaceutical ingredient, API), and the final drug product that meet acceptance criteria. We aimed to develop an automated system for production of CGMP grade of PET radiopharmaceuticals. Methods. The hardware and software of the automated synthesizer that fit in the hot cell under cGMP requirement were developed. Examples of production yield and purity for 68Ga-DOTATATE and 18F-FDG at CGMP facility were optimized. Analytical assays and acceptance criteria for cGMP grade of 68Ga-DOTATATE and 18F-FDG were established. Results. CGMP facility for the production of PET radiopharmaceuticals has been established. Radio-TLC and HPLC analyses of 68Ga-DOTATATE and 18F-FDG showed that the radiochemical purity was 92% and 96%, respectively. The products were sterile and pyrogenic-free. Conclusion. CGMP compliance of radiopharmaceuticals has been reviewed. 68Ga-DOTATATE and 18F-FDG were synthesized with high radiochemical yield under CGMP process. PMID:25276810

  20. T156. IN VIVO CHARACTERIZATION OF THE FIRST AGONIST DOPAMINE D1 RECEPTORS PET IMAGING TRACER [18F]MNI-968 IN HUMAN

    PubMed Central

    Tamagnan, Gilles; Barret, Olivier; Alagille, David; Carroll, Vincent; Madonia, Jennifer; Constantinescu, Cristian; SanDiego, Christine; Papin, Caroline; Morley, Thomas; Russell, David; McCarthy, Timothy; Zhang, Lei; Gray, David; Villalobos, Anna; Lee, Chewah; Chen, Jianqing; Seibyl, John; Marek, Kenneth

    2018-01-01

    Abstract Background D1 receptors, which couple to inhibitory G-proteins, have been shown to regulate neuronal growth and development, mediate some behavioral responses. Its function has been shown to be altered in both neurologic and psychiatric disorders. To date, there is a lack of agonist PET tracers for the D1 receptors labeled with 18F with relevance in clinical studies. We report the evaluation in non-human primates of [18F]MNI-968 (PF-06730110), a novel PET radiotracer of the D1 receptors Methods Four brain PET studies, 2 baselines and 2 blockade studies using PF-2562, a D1 partial agonist compound, were conducted for 90 min in two rhesus monkeys with [18F]MNI-968 (169 ± 31 MBq). [18F]PF-06730110 was administered at the same dose level for both monkeys as a bolus followed by a 2-hour infusion, with [18F]MNI-968 administered 30 min into the infusion. Additionally, six brain PET studies were conducted over 180 min (317 ± 49 MBq) in 6 healthy human volunteers (3 test/retest and 3 test). PET data were modeled with 2-tissue compartmental model (2T), Logan graphical analysis (LGA), and non-invasive Logan graphical analysis (NI-LGA) with cerebellar cortex as reference region to estimate total distribution volume VT, and binding potential BPND. For the blockade studies in rhesus monkeys, occupancy was estimated from BPND at baseline and post blockade. Results In rhesus monkeys, [18F]MNI-968 (PF-06730110), penetrated the brain with a peak whole-brain uptake up to ~3% of the injected dose at ~ 6 min post injection and showed a fast washout. The highest signal was found in the caudate, putamen, with moderate extrastriatal uptake. The lowest signal was in the cerebellum. BPND values were up to ~1.4 in the putamen. All three quantification methods (2T, LGA and NI-LGA) were in excellent agreement, with a similar estimated D1 receptors occupancy of PF-06730110 of ~40% for both monkeys in the caudate and putamen. In human, [18F]MNI-968 kinetics appeared to be faster

  1. Association of In Vivo [18F]AV-1451 Tau PET Imaging Results With Cortical Atrophy and Symptoms in Typical and Atypical Alzheimer Disease

    PubMed Central

    Xia, Chenjie; Makaretz, Sara J.; Caso, Christina; McGinnis, Scott; Gomperts, Stephen N.; Sepulcre, Jorge; Gomez-Isla, Teresa; Hyman, Bradley T.; Schultz, Aaron; Vasdev, Neil; Johnson, Keith A.

    2017-01-01

    Importance Previous postmortem studies have long demonstrated that neurofibrillary tangles made of hyperphosphorylated tau proteins are closely associated with Alzheimer disease clinical phenotype and neurodegeneration pattern. Validating these associations in vivo will lead to new diagnostic tools for Alzheimer disease and better understanding of its neurobiology. Objective To examine whether topographical distribution and severity of hyperphosphorylated tau pathologic findings measured by fluorine 18labeled AV-1451 ([18F]AV-1451) positron emission tomographic (PET) imaging are linked with clinical phenotype and cortical atrophy in patients with Alzheimer disease. Design, Setting, and Participants This observational case series, conducted from July 1, 2012, to July 30, 2015, in an outpatient referral center for patients with neurodegenerative diseases, included 6 patients: 3 with typical amnesic Alzheimer disease and 3 with atypical variants (posterior cortical atrophy, logopenic variant primary progressive aphasia, and corticobasal syndrome). Patients underwent [18F]AV-1451 PET imaging to measure tau burden, carbon 11–labeled Pittsburgh Compound B ([11C]PiB) PET imaging to measure amyloid burden, and structural magnetic resonance imaging to measure cortical thickness. Seventy-seven age-matched controls with normal cognitive function also underwent structural magnetic resonance imaging but not tau or amyloid PET imaging. Main Outcomes and Measures Tau burden, amyloid burden, and cortical thickness. Results In all 6 patients (3 women and 3 men; mean age 61.8 years), the underlying clinical phenotype was associated with the regional distribution of the [18F]AV-1451 signal. Furthermore, within 68 cortical regions of interest measured from each patient, the magnitude of cortical atrophy was strongly correlated with the magnitude of [18F]AV-1451 binding (3 patients with amnesic Alzheimer disease, r = –0.82; P < .001; r = –0.70; P < .001; r

  2. Dryden/Edwards 1994 Thrust-Vectoring Aircraft Fleet - F-18 HARV, X-31, F-16 MATV

    NASA Technical Reports Server (NTRS)

    1994-01-01

    The three thrust-vectoring aircraft at Edwards, California, each capable of flying at extreme angles of attack, cruise over the California desert in formation during flight in March 1994. They are, from left, NASA's F-18 High Alpha Research Vehicle (HARV), flown by the NASA Dryden Flight Research Center; the X-31, flown by the X-31 International Test Organization (ITO) at Dryden; and the Air Force F-16 Multi-Axis Thrust Vectoring (MATV) aircraft. All three aircraft were flown in different programs and were developed independently. The NASA F-18 HARV was a testbed to produce aerodynamic data at high angles of attack to validate computer codes and wind tunnel research. The X-31 was used to study thrust vectoring to enhance close-in air combat maneuvering, while the F-16 MATV was a demonstration of how thrust vectoring could be applied to operational aircraft.

  3. Decomposed Fragment Identification in C_8F_18 RF Plasma for a-C:F Film Production

    NASA Astrophysics Data System (ADS)

    Sakai, Yosuke; Tazawa, Shota; Bratescu, Maria; Suda, Yoshiyuki; Sugawara, Hirotake

    2004-09-01

    Amorphous fluorocarbon polymer (a-C:F) film shows excellent insulation properties such as low dielectric constant (<2.5), high dielectric strength (>2 MV/cm), low surface energy, and chemical inertness. Therefore, we have studied this film for a purpose of an additional insulator to enhance the breakdown voltage in an alternative to a SF6 gas insulation system. The films are prepared using a C_8F_18 vapor RF plasma. When per-fluorocarbon, such as C_8F_18 as source gases, then the deposition rate becomes roughly two orders of magnitude higher than that obtained from conventional low molecular-weight source monomers (CF_4, C_2F_6, C_3F_6, and C_4F_8) [1]. The breakdown voltage (V_s) of N_2, Ar and He gases between the a-C:F film coated Al sphere-sphere electrodes for a gas pressure (p) times gap length (d), pd=0.1-100 Torr¥cm, was studied as well. Then, Vs between the a-C:F film coated electrodes was a several times higher than that between the Al electrodes in the present pd range[2]. In this work, the decomposed species of C_8F_18 in the plasma were identified using emission spectra from the plasma and Quadra-pole mass spectrograph, and the reason why the high deposition rate was obtained was discussed. The physical and chemical properties of a-C:F film was analyzed. [1] C.P.Lungu, et.al., Jpn. J. Appl. Phys. 38 (12B) L1544 - L1546 (1999) [2] C.Biloiu, et.al., Jpn. J. Appl. Phys. 42 (2B) L 201- L203 (2003) Work supported by Grant-in-Aid for Scientific Research (B), JSPS.

  4. DETECTION OF WHOLE BODY OXIDATIVE STRESS IN URINE USING OXYGEN-18 LABELING

    EPA Science Inventory

    DETECTION OF WHOLE BODY OXIDATIVE STRESS IN URINE USING OXYGEN-18 LABELING. R Slade, J L McKee and G E Hatch. PTB, ETD, NHEERL, ORD, USEPA, Research Triangle Park, NC, USA.
    Reliable non-invasive markers for detecting oxidative stress in vivo are currently not available. We pr...

  5. Aerodynamics of powered missile separation from F/A-18 aircraft

    NASA Technical Reports Server (NTRS)

    Ahmad, J. U.; Shanks, S. P.; Buning, P. G.

    1993-01-01

    A 3D dynamic 'chimera' algorithm that solves the thin-layer Navier-Stokes equations over multiple moving bodies was modified to numerically simulate the aerodynamics, missile dynamics, and missile plume interactions of a missile separating from a generic wing and from an F/A-18 aircraft in transonic flow. The missile is mounted below the wing for missile separation from the wing and on the F/A-18 fuselage at the engine inlet side for missile separation from aircraft. Static and powered missile separation cases are considered to examine the influence of the missile and plume on the wing and F/A-18 fuselage and engine inlet. The aircraft and missile are at two degrees angle of attack, Reynolds number of 10 million, freestream Mach number of 1.05 and plume Mach number of 3.0. The computational results show the details of the flow field.

  6. .sup.18 F-4-Fluoroantipyrine

    DOEpatents

    Shiue, Chyng-Yann; Wolf, Alfred P.

    1984-03-13

    The novel radioactive compound .sup.18 F-4-fluoroantipyrine having high specific activity which can be used in nuclear medicine in diagnostic applications, prepared by the direct fluorination of antipyrine in acetic acid with radioactive fluorine at room temperature and purifying said radioactive compound by means of gel chromatography with ethyl acetate as eluent is disclosed. The non-radioactive 4-fluoroantipyrine can also be prepared by the direct fluorination of antipyrine in acetic acid with molecular fluorine at room temperature and purified by means of gel chromotography with ethyl acetate eluent.

  7. [Is 3'-deoxy-3'- [18F] fluorothymidine ([18F]-FLT) the next tracer for routine clinical PET after R [18F]-FDG?].

    PubMed

    Couturier, Olivier; Leost, Françoise; Campone, Mario; Carlier, Thomas; Chatal, Jean-François; Hustinx, Roland

    2005-09-01

    Positron emission tomography (PET) with [18F]-FDG is now firmly established as a clinical tool in oncology. Its applications are however limited in some indications, due to the lack of specificity of its uptake mechanism for tumors, or the low avidity of some cancer types such as prostate. Alternative tracers are thus being developed, in order to fill up this void. Proliferation as a biological target is particularly attractive in cancer imaging. From that perspective, fluorothymidine ([18F]-FLT or FLT) has generated a strong interest among the scientific community, especially since the radiosynthesis process has been improved and simplified, thus making possible to envision a routine use for the tracer. This article aims at summarizing the status of the current scientific data regarding FLT. The uptake mechanism of FLT is well known, relying on the thymidine kinase 1 (TK1) enzymatic activity, and thus on DNA synthesis. Preclinical studies have shown a clear relationship between tracer accumulation and level of tumor proliferation, even though DNA salvage pathwayss intervene in the process and may complicate the interpretation of the results. Several clinical studies suggest a good specificity for tumor, albeit with a lower sensitivity than with FDG. In all likelihood however, the future of FLT lies in the evaluation of antitumor response and possibly the pretherapeutic prognostic characterization, rather than in the diagnosis and staging of malignancies. Although the scientific data regarding this issue remain limited, initial results are encouraging. Further significant work remains to be done in order to fully assess the clinical performances of the tracer, on the one hand, and to determine its place relative to FDG and other emerging tracers, on the other hand. Until these studies are completed, FLT should be considered as a promising tracer, but remaining at an experimental stage of its development.

  8. Feasibility of assessing [(18)F]FDG lung metabolism with late dynamic PET imaging.

    PubMed

    Laffon, Eric; de Clermont, Henri; Vernejoux, Jean-Marc; Jougon, Jacques; Marthan, Roger

    2011-04-01

    The aim of this work was to non-invasively establish the feasibility of assessing 2-deoxy-2-[(18)F]fluoro-D-glucose ((18)F-FDG) lung metabolism with the use of a late dynamic positron emission tomograpy (PET) acquisition, i.e., beyond 2 h after injection. The present method has been probed in 11 patients without any respiratory disease, under fasting conditions, by assessing mean values of (18)F-FDG lung metabolism. A kinetic model analysis has been implemented on a simple calculation sheet. An arbitrary (population based) input function has been used in each individual, which was obtained from literature data. In the healthy lung, no (18)F-FDG release was found, and the mean values (±SD) of the (18)F-FDG uptake rate constant and of the fraction of the free tracer in blood and interstitial volume were: K = 0.0016 min(-1) (±0.0005), and F = 0.18 (±0.10), respectively. These results were in very close agreement with literature data that were obtained by both three-compartment model analysis and Patlak graphical analysis (gold standards), and that used an invasive blood sampling. Furthermore, K and the standard uptake value index have been compared. We conclude that assessing lung metabolism of (18)F-FDG in humans with the use of late dynamic PET imaging is feasible. The arbitrary input function of this non-invasive feasibility study could be replaced in further experiments by an input function obtained by arterial sampling. It is suggested that this method may prove useful to quantify (18)F-FDG lung metabolism under pathological conditions.

  9. Monoamine oxidase B inhibitor, selegiline, reduces 18F-THK5351 uptake in the human brain.

    PubMed

    Ng, Kok Pin; Pascoal, Tharick A; Mathotaarachchi, Sulantha; Therriault, Joseph; Kang, Min Su; Shin, Monica; Guiot, Marie-Christine; Guo, Qi; Harada, Ryuichi; Comley, Robert A; Massarweh, Gassan; Soucy, Jean-Paul; Okamura, Nobuyuki; Gauthier, Serge; Rosa-Neto, Pedro

    2017-03-31

    18 F-THK5351 is a quinoline-derived tau imaging agent with high affinity to paired helical filaments (PHF). However, high levels of 18 F-THK5351 retention in brain regions thought to contain negligible concentrations of PHF raise questions about the interpretation of the positron emission tomography (PET) signals, particularly given previously described interactions between quinolone derivatives and monoamine oxidase B (MAO-B). Here, we tested the effects of MAO-B inhibition on 18 F-THK5351 brain uptake using PET and autoradiography. Eight participants (five mild cognitive impairment, two Alzheimer's disease, and one progressive supranuclear palsy) had baseline 18 F-AZD4694 and 18 F-THK5351 scans in order to quantify brain amyloid and PHF load, respectively. A second 18 F-THK5351 scan was conducted 1 week later, 1 h after a 10-mg oral dose of selegiline. Three out of eight patients also had a third 18 F-THK5351 scan 9-28 days after the selegiline administration. The primary outcome measure was standardized uptake value (SUV), calculated using tissue radioactivity concentration from 50 to 70 min after 18 F-THK5351 injection, normalizing for body weight and injected radioactivity. The SUV ratio (SUVR) was determined using the cerebellar cortex as the reference region. 18 F-THK5351 competition autoradiography studies in postmortem tissue were conducted using 150 and 500 nM selegiline. At baseline, 18 F-THK5351 SUVs were highest in the basal ganglia (0.64 ± 0.11) and thalamus (0.62 ± 0.14). In the post-selegiline scans, the regional SUVs were reduced on average by 36.7% to 51.8%, with the greatest reduction noted in the thalamus (51.8%) and basal ganglia (51.4%). MAO-B inhibition also reduced 18 F-THK5351 SUVs in the cerebellar cortex (41.6%). The SUVs remained reduced in the three patients imaged at 9-28 days. Tissue autoradiography confirmed the effects of MAO-B inhibition on 18 F-THK5351 uptake. These results indicate that the interpretation of 18 F

  10. Prospective trial evaluating the sensitivity and specificity of 3,4-dihydroxy-6-[18F]-fluoro-L-phenylalanine (18F-DOPA) PET and MRI in patients with recurrent gliomas.

    PubMed

    Youland, Ryan S; Pafundi, Deanna H; Brinkmann, Debra H; Lowe, Val J; Morris, Jonathan M; Kemp, Bradley J; Hunt, Christopher H; Giannini, Caterina; Parney, Ian F; Laack, Nadia N

    2018-05-01

    Treatment-related changes can be difficult to differentiate from progressive glioma using MRI with contrast (CE). The purpose of this study is to compare the sensitivity and specificity of 18F-DOPA-PET and MRI in patients with recurrent glioma. Thirteen patients with MRI findings suspicious for recurrent glioma were prospectively enrolled and underwent 18F-DOPA-PET and MRI for neurosurgical planning. Stereotactic biopsies were obtained from regions of concordant and discordant PET and MRI CE, all within regions of T2/FLAIR signal hyperintensity. The sensitivity and specificity of 18F-DOPA-PET and CE were calculated based on histopathologic analysis. Receiver operating characteristic curve analysis revealed optimal tumor to normal (T/N) and SUVmax thresholds. In the 37 specimens obtained, 51% exhibited MRI contrast enhancement (M+) and 78% demonstrated 18F-DOPA-PET avidity (P+). Imaging characteristics included M-P- in 16%, M-P+ in 32%, M+P+ in 46% and M+P- in 5%. Histopathologic review of biopsies revealed grade II components in 16%, grade III in 43%, grade IV in 30% and no tumor in 11%. MRI CE sensitivity for recurrent tumor was 52% and specificity was 50%. PET sensitivity for tumor was 82% and specificity was 50%. A T/N threshold > 2.0 altered sensitivity to 76% and specificity to 100% and SUVmax > 1.36 improved sensitivity and specificity to 94 and 75%, respectively. 18F-DOPA-PET can provide increased sensitivity and specificity compared with MRI CE for visualizing the spatial distribution of recurrent gliomas. Future studies will incorporate 18F-DOPA-PET into re-irradiation target volume delineation for RT planning.

  11. TANK 18-F AND 19-F TANK FILL GROUT SCALE UP TEST SUMMARY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stefanko, D.; Langton, C.

    2012-01-03

    High-level waste (HLW) tanks 18-F and 19-F have been isolated from FTF facilities. To complete operational closure the tanks will be filled with grout for the purpose of: (1) physically stabilizing the tanks, (2) limiting/eliminating vertical pathways to residual waste, (3) entombing waste removal equipment, (4) discouraging future intrusion, and (5) providing an alkaline, chemical reducing environment within the closure boundary to control speciation and solubility of select radionuclides. This report documents the results of a four cubic yard bulk fill scale up test on the grout formulation recommended for filling Tanks 18-F and 19-F. Details of the scale upmore » test are provided in a Test Plan. The work was authorized under a Technical Task Request (TTR), HLE-TTR-2011-008, and was performed according to Task Technical and Quality Assurance Plan (TTQAP), SRNL-RP-2011-00587. The bulk fill scale up test described in this report was intended to demonstrate proportioning, mixing, and transportation, of material produced in a full scale ready mix concrete batch plant. In addition, the material produced for the scale up test was characterized with respect to fresh properties, thermal properties, and compressive strength as a function of curing time.« less

  12. 18F-FDG PET/CT in breast cancer: Evidence-based recommendations in initial staging.

    PubMed

    Caresia Aroztegui, Ana Paula; García Vicente, Ana María; Alvarez Ruiz, Soledad; Delgado Bolton, Roberto Carlos; Orcajo Rincon, Javier; Garcia Garzon, Jose Ramon; de Arcocha Torres, Maria; Garcia-Velloso, Maria Jose

    2017-10-01

    Current guidelines do not systematically recommend 18F-FDG PET/CT for breast cancer staging; and the recommendations and level of evidence supporting its use in different groups of patients vary among guidelines. This review summarizes the evidence about the role of 18F-FDG PET/CT in breast cancer staging and the therapeutic and prognostic impact accumulated in the last decade. Other related aspects, such as the association of metabolic information with biology and prognosis are considered and evidence-based recommendations for the use of 18F-FDG PET/CT in breast cancer staging are offered. We systematically searched MEDLINE for articles reporting studies with at least 30 patients related to clinical questions following the Problem/Population, Intervention, Comparison, and Outcome framework. We critically reviewed the selected articles and elaborated evidence tables structuring the summarized information into methodology, results, and limitations. The level of evidence and the grades of recommendation for the use of 18F-FDG PET/CT in different contexts are summarized. Level III evidence supports the use of 18F-FDG PET/CT for initial staging in patients with recently diagnosed breast cancer; the diagnostic and therapeutic impact of the 18F-FDG PET/CT findings is sufficient for a weak recommendation in this population. In patients with locally advanced breast cancer, level II evidence supports the use of 18F-FDG PET/CT for initial staging; the diagnostic and therapeutic impact of the 18F-FDG PET/CT findings is sufficient for a strong recommendation in this population. In patients with recently diagnosed breast cancer, the metabolic information from baseline 18F-FDG PET/CT is associated with tumor biology and has prognostic implications, supported by level II evidence. In conclusion, 18F-FDG PET/CT is not recommended for staging all patients with early breast cancer, although evidence of improved regional and systemic staging supports its use in locally advanced

  13. Evaluation of the novel myocardial perfusion positron-emission tomography tracer 18F-BMS-747158-02: comparison to 13N-ammonia and validation with microspheres in a pig model.

    PubMed

    Nekolla, S G; Reder, S; Saraste, A; Higuchi, T; Dzewas, G; Preissel, A; Huisman, M; Poethko, T; Schuster, T; Yu, M; Robinson, S; Casebier, D; Henke, J; Wester, H J; Schwaiger, M

    2009-05-05

    Positron-emission tomography (PET) tracers for myocardial perfusion are commonly labeled with short-lived isotopes that limit their widespread clinical use. 18F-BMS-747158-02 (18F-BMS) is a novel pyridaben derivative that was evaluated for assessment of myocardial perfusion by comparison with 13N-ammonia (13NH3) and with radioactive microspheres in a pig model. Fourteen pigs injected with 500 MBq of 13NH3 or 100 to 200 MBq of 18F-BMS underwent dynamic PET at rest and during pharmacological stress. In 8 of these pigs, 18F-BMS was injected during stress combined with transient, 2.5-minute constriction of the left anterior descending coronary artery. Radioactive microspheres were coinjected with 18F-BMS. Ratios of myocardial tracer uptake to surrounding tissues were determined, and myocardial blood flow was quantified by compartmental modeling. Both tracers showed high and homogeneous myocardial uptake. Compared with 13NH3, 18F-BMS showed higher activity ratios between myocardium and blood (rest 2.5 versus 4.1; stress 2.1 versus 5.8), liver (rest 1.2 versus 1.8; stress 0.7 versus 2.0), and lungs (rest 2.5 versus 4.2; stress 2.9 versus 6.4). Regional myocardial blood flow assessed with 18F-BMS PET showed good correlation (r=0.88, slope=0.84) and agreement (mean difference -0.10 [25th percentile -0.3, 75th percentile 0.1 mL x min(-1) x g(-1)]) with that measured with radioactive microspheres over a flow range from 0.1 to 3.0 mL x min(-1) x g(-1). The extent of defects induced by left anterior descending coronary artery constriction measured by 18F-BMS and microspheres also correlated closely (r=0.63, slope=1.1). 18F-BMS-747158-02 is a very attractive new PET perfusion tracer that allows quantitative assessment of regional myocardial perfusion over a wide flow range. The long half-life of 18F renders this tracer useful for clinical PET/CT applications in the workup of patients with suspected or proven coronary artery disease.

  14. [18F-Fluorocholine PET-CT for localization of parathyroid adenomas].

    PubMed

    Kluijfhout, Wouter P; Vriens, Menno R; Borel Rinkes, Inne H M; Valk, Gerlof D; de Klerk, John M H; de Keizer, Bart

    2015-01-01

    18F-fluorocholine PET-CT is a new imaging modality for the localization of pathological parathyroid glands in patients with primary hyperparathyroidism. The PET-CT is a combination scan that uses both the physiological information from the PET and the anatomical information from the CT. Uptake of the radio-isotope 18F-fluorocholine is increased in pathological parathyroid glands. 18F-fluorocholine PET-CT helps clinicians to localize the pathological parathyroid glands where conventional modalities fail to do so. This enables surgeons to carry out targeted minimal invasive surgery. It may also prevent the patient having to undergo a more extensive exploration, with its associated risks, and alleviate the necessity of taking medications with side effects. Although the literature on this subject is still scarce, preliminary results are promising. As any hospital with a PET-CT can perform the scan, we expect that its use in patients with hyperparathyroidism will increase over the next few years.

  15. The Role of 18F-FDG PET/CT Integrated Imaging in Distinguishing Malignant from Benign Pleural Effusion.

    PubMed

    Sun, Yajuan; Yu, Hongjuan; Ma, Jingquan; Lu, Peiou

    2016-01-01

    The aim of our study was to evaluate the role of 18F-FDG PET/CT integrated imaging in differentiating malignant from benign pleural effusion. A total of 176 patients with pleural effusion who underwent 18F-FDG PET/CT examination to differentiate malignancy from benignancy were retrospectively researched. The images of CT imaging, 18F-FDG PET imaging and 18F-FDG PET/CT integrated imaging were visually analyzed. The suspected malignant effusion was characterized by the presence of nodular or irregular pleural thickening on CT imaging. Whereas on PET imaging, pleural 18F-FDG uptake higher than mediastinal activity was interpreted as malignant effusion. Images of 18F-FDG PET/CT integrated imaging were interpreted by combining the morphologic feature of pleura on CT imaging with the degree and form of pleural 18F-FDG uptake on PET imaging. One hundred and eight patients had malignant effusion, including 86 with pleural metastasis and 22 with pleural mesothelioma, whereas 68 patients had benign effusion. The sensitivities of CT imaging, 18F-FDG PET imaging and 18F-FDG PET/CT integrated imaging in detecting malignant effusion were 75.0%, 91.7% and 93.5%, respectively, which were 69.8%, 91.9% and 93.0% in distinguishing metastatic effusion. The sensitivity of 18F-FDG PET/CT integrated imaging in detecting malignant effusion was higher than that of CT imaging (p = 0.000). For metastatic effusion, 18F-FDG PET imaging had higher sensitivity (p = 0.000) and better diagnostic consistency with 18F-FDG PET/CT integrated imaging compared with CT imaging (Kappa = 0.917 and Kappa = 0.295, respectively). The specificities of CT imaging, 18F-FDG PET imaging and 18F-FDG PET/CT integrated imaging were 94.1%, 63.2% and 92.6% in detecting benign effusion. The specificities of CT imaging and 18F-FDG PET/CT integrated imaging were higher than that of 18F-FDG PET imaging (p = 0.000 and p = 0.000, respectively), and CT imaging had better diagnostic consistency with 18F-FDG PET/CT integrated

  16. The Role of 18F-FDG PET/CT Integrated Imaging in Distinguishing Malignant from Benign Pleural Effusion

    PubMed Central

    Sun, Yajuan; Yu, Hongjuan; Ma, Jingquan

    2016-01-01

    Objective The aim of our study was to evaluate the role of 18F-FDG PET/CT integrated imaging in differentiating malignant from benign pleural effusion. Methods A total of 176 patients with pleural effusion who underwent 18F-FDG PET/CT examination to differentiate malignancy from benignancy were retrospectively researched. The images of CT imaging, 18F-FDG PET imaging and 18F-FDG PET/CT integrated imaging were visually analyzed. The suspected malignant effusion was characterized by the presence of nodular or irregular pleural thickening on CT imaging. Whereas on PET imaging, pleural 18F-FDG uptake higher than mediastinal activity was interpreted as malignant effusion. Images of 18F-FDG PET/CT integrated imaging were interpreted by combining the morphologic feature of pleura on CT imaging with the degree and form of pleural 18F-FDG uptake on PET imaging. Results One hundred and eight patients had malignant effusion, including 86 with pleural metastasis and 22 with pleural mesothelioma, whereas 68 patients had benign effusion. The sensitivities of CT imaging, 18F-FDG PET imaging and 18F-FDG PET/CT integrated imaging in detecting malignant effusion were 75.0%, 91.7% and 93.5%, respectively, which were 69.8%, 91.9% and 93.0% in distinguishing metastatic effusion. The sensitivity of 18F-FDG PET/CT integrated imaging in detecting malignant effusion was higher than that of CT imaging (p = 0.000). For metastatic effusion, 18F-FDG PET imaging had higher sensitivity (p = 0.000) and better diagnostic consistency with 18F-FDG PET/CT integrated imaging compared with CT imaging (Kappa = 0.917 and Kappa = 0.295, respectively). The specificities of CT imaging, 18F-FDG PET imaging and 18F-FDG PET/CT integrated imaging were 94.1%, 63.2% and 92.6% in detecting benign effusion. The specificities of CT imaging and 18F-FDG PET/CT integrated imaging were higher than that of 18F-FDG PET imaging (p = 0.000 and p = 0.000, respectively), and CT imaging had better diagnostic consistency with

  17. Metastatic Neuroendocrine Tumour in a Renal Transplant Recipient: Dual-Tracer PET-CT with (18)F-FDG and (68)Ga-DOTANOC in This Rare Setting.

    PubMed

    Karunanithi, Sellam; Roy, Shambo Guha; Sharma, Punit; Yadav, Rajni; Bal, Chandrasekhar; Kumar, Rakesh

    2015-03-01

    Recipients of renal transplant are at increased risk of developing various malignancies, especially post-transplant lymphoproliferative disorder (PTLD) and skin cancers. Neuroendocrine tumours (NET) of the gastrointestinal tract have not been reported in this setting. Here we describe the case of a 75-year-old male who had undergone renal transplant 8 years back and now presented with significant weight loss and backache, clinically suspected as PTLD. (18)F-Fluordeoxyglucose ((18)F-FDG) positron emission tomography-computed tomography (PET-CT) showed hypermetabolic lesions in the liver and rectum, raising the suspicion of PTLD. However, biopsy from the liver lesion showed poorly differentiated NET. (68)Ga-labelled [1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid]-1-NaI(3)-octreotide ((68)Ga-DOTANOC) PET-CT was then done, which confirmed the primary lesion in the rectum with liver metastases.

  18. In vivo PET imaging of beta-amyloid deposition in mouse models of Alzheimer's disease with a high specific activity PET imaging agent [(18)F]flutemetamol.

    PubMed

    Snellman, Anniina; Rokka, Johanna; López-Picón, Francisco R; Eskola, Olli; Salmona, Mario; Forloni, Gianluigi; Scheinin, Mika; Solin, Olof; Rinne, Juha O; Haaparanta-Solin, Merja

    2014-01-01

    The purpose of the study was to evaluate the applicability of (18) F-labelled amyloid imaging positron emission tomography (PET) agent [ (18) F]flutemetamol to detect changes in brain beta-amyloid (Aβ) deposition in vivo in APP23, Tg2576 and APPswe-PS1dE9 mouse models of Alzheimer's disease. We expected that the high specific activity of [ (18) F]flutemetamol would make it an attractive small animal Aβ imaging agent. [ (18) F]flutemetamol uptake in the mouse brain was evaluated in vivo at 9 to 22 months of age with an Inveon Multimodality PET/CT camera (Siemens Medical Solutions USA, Knoxville, TN, USA). Retention in the frontal cortex (FC) was evaluated by Logan distribution volume ratios (DVR) and FC/cerebellum (CB) ratios during the late washout phase (50 to 60 min). [ (18) F]flutemetamol binding to Aβ was also evaluated in brain slices by in vitro and ex vivo autoradiography. The amount of Aβ in the brain slices was determined with Thioflavin S and anti-Aβ1-40 immunohistochemistry. In APP23 mice, [ (18) F]flutemetamol retention in the FC increased from 9 to 18 months. In younger mice, DVR and FC/CB50-60 were 0.88 (0.81) and 0.88 (0.89) at 9 months (N = 2), and 0.98 (0.93) at 12 months (N = 1), respectively. In older mice, DVR and FC/CB50-60 were 1.16 (1.15) at 15 months (N = 1), 1.13 (1.16) and 1.35 (1.35) at 18 months (N = 2), and 1.05 (1.31) at 21 months (N = 1). In Tg2576 mice, DVR and FC/CB50-60 showed modest increasing trends but also high variability. In APPswe-PS1dE9 mice, DVR and FC/CB50-60 did not increase with age. Thioflavin S and anti-Aβ1-40 positive Aβ deposits were present in all transgenic mice at 19 to 22 months, and they co-localized with [ (18) F]flutemetamol binding in the brain slices examined with in vitro and ex vivo autoradiography. Increased [ (18) F]flutemetamol retention in the brain was detected in old APP23 mice in vivo. However, the high specific activity of [ (18) F]flutemetamol did not provide a

  19. Defining optimal tracer activities in pediatric oncologic whole-body 18F-FDG-PET/MRI.

    PubMed

    Gatidis, Sergios; Schmidt, Holger; la Fougère, Christian; Nikolaou, Konstantin; Schwenzer, Nina F; Schäfer, Jürgen F

    2016-12-01

    To explore the feasibility of reducing administered tracer activities and to assess optimal activities for combined 18 F-FDG-PET/MRI in pediatric oncology. 30 18 F-FDG-PET/MRI examinations were performed on 24 patients with known or suspected solid tumors (10 girls, 14 boys, age 12 ± 5.6 [1-18] years; PET scan duration: 4 min per bed position). Low-activity PET images were retrospectively simulated from the originally acquired data sets using randomized undersampling of list mode data. PET data of different simulated administered activities (0.25-2.5 MBq/kg body weight) were reconstructed with or without point spread function (PSF) modeling. Mean and maximum standardized uptake values (SUV mean and SUV max ) as well as SUV variation (SUV var ) were measured in physiologic organs and focal FDG-avid lesions. Detectability of organ structures and of focal 18 F-FDG-avid lesions as well as the occurrence of false-positive PET lesions were assessed at different simulated tracer activities. Subjective image quality steadily declined with decreasing tracer activities. Compared to the originally acquired data sets, mean relative deviations of SUV mean and SUV max were below 5 % at 18 F-FDG activities of 1.5 MBq/kg or higher. Over 95 % of anatomic structures and all pathologic focal lesions were detectable at 1.5 MBq/kg 18 F-FDG. Detectability of anatomic structures and focal lesions was significantly improved using PSF. No false-positive focal lesions were observed at tracer activities of 1 MBq/kg 18 F-FDG or higher. Administration of 18 F-FDG activities of 1.5 MBq/kg is, thus, feasible without obvious diagnostic shortcomings, which is equivalent to a dose reduction of more than 50 % compared to current recommendations. Significant reduction in administered 18 F-FDG tracer activities is feasible in pediatric oncologic PET/MRI. Appropriate activities of 18 F-FDG or other tracers for specific clinical questions have to be further established in selected patient

  20. Oncogene pathway activation in mammary tumors dictates [18F]-FDG-PET uptake

    PubMed Central

    Alvarez, James V.; Belka, George K.; Pan, Tien-chi; Chen, Chien-Chung; Blankemeyer, Eric; Alavi, Abass; Karp, Joel; Chodosh, Lewis A.

    2015-01-01

    Increased glucose utilization is a hallmark of human cancer that is used to image tumors clinically. In this widely used application, glucose uptake by tumors is monitored by positron emission tomography (PET) of the labeled glucose analog F-18-2-fluoro-2-deoxyglucose (18F-FDG). Despite its widespread clinical use, the cellular and molecular mechanisms that determine FDG uptake - a tool that can monitor tumor heterogeneity - remain poorly understood. In this study, we compared FDG uptake in mammary tumors driven by the Akt1, c-MYC, HER2/neu, Wnt1 or H-Ras oncogenes in genetically engineered mice, correlating it to tumor growth, cell proliferation and levels of gene expression involved in key steps of glycolytic metabolism. We found that FDG uptake by tumors was dictated principally by the driver oncogene and was not independently associated with tumor growth or cellular proliferation. Oncogene downregulation resulted in a rapid decrease in FDG uptake, preceding effects on tumor regression, irrespective of the baseline level of uptake. FDG uptake correlated positively with expression of hexokinase-2 (HK2) and HIF-1α and associated negatively with PFK-2b expression and p-AMPK. The correlation of HK2 and FDG uptake was independent of all variables tested, including the initiating oncogene, suggesting that HK2 is an independent predictor of FDG uptake. In contrast, expression of Glut1 was correlated with FDG uptake only in tumors driven by Akt or HER2/neu. Together, these results showed that the oncogenic pathway activated within a tumor is a primary determinant of its FDG uptake, mediated by key glycolytic enzymes that provide a framework to interpret effects on this key parameter in clinical imaging. PMID:25239452

  1. 18F-Fluorodeoxyglucose Positron Emission Tomography/CT Scanning in Diagnosing Vascular Prosthetic Graft Infection

    PubMed Central

    Saleem, Ben R.; Pol, Robert A.; Slart, Riemer H. J. A.; Reijnen, Michel M. P. J.; Zeebregts, Clark J.

    2014-01-01

    Vascular prosthetic graft infection (VPGI) is a severe complication after vascular surgery. CT-scan is considered the diagnostic tool of choice in advanced VPGI. The incidence of a false-negative result using CT is relatively high, especially in the presence of low-grade infections. 18F-fluorodeoxyglucose positron emission tomography (18F-FDG PET) scanning has been suggested as an alternative for the diagnosis and assessment of infectious processes. Hybrid 18F-FDG PET/CT has established the role of 18F-FDG PET for the assessment of suspected VPGI, providing accurate anatomic localization of the site of infection. However, there are no clear guidelines for the interpretation of the uptake patterns of 18F-FDG as clinical tool for VPGI. Based on the available literature it is suggested that a linear, diffuse, and homogeneous uptake should not be regarded as an infection whereas focal or heterogeneous uptake with a projection over the vessel on CT is highly suggestive of infection. Nevertheless, 18F-FDG PET and 18F-FDG PET/CT can play an important role in the detection of VPGI and monitoring response to treatment. However an accurate uptake and pattern recognition is warranted and cut-off uptake values and patterns need to be standardized before considering the technique to be the new standard. PMID:25210712

  2. Recoil /sup 18/F chemistry. XI. High pressure investigation of 1,1-difluoroethane

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Manning, R.G.; Root, J.W.

    1980-06-15

    Nuclear recoil /sup 18/F reactions in CH/sub 3/CHF/sub 2/ have been investigated throughout the effective pressure range 0.3--190 atm. The principal reaction channel is F-to-HF abstraction for which the combined yield from quasithermal and energetic processes in the presence of 5 mole% H/sub 2/S additive is 83.4% +- 0.2%. A reaction mechanism is proposed that involves the organic product forming channels F-for-F, F-for-..cap alpha..H, F-for-..beta..H, F-for-CH/sub 3/ and F-for-CHF/sub 2/. The results are compared with those reported for the /sup 18/F+CH/sub 3/CF/sub 3/ system.

  3. Initial in vivo PET imaging of 5-HT1A receptors with 3-[18F]mefway

    PubMed Central

    Wooten, Dustin W; Hillmer, Ansel T; Murali, Dhanabalan; Barnhart, Todd E; Thio, Joanne P; Bajwa, Alisha K; Bonab, Ali A; Normandin, Marc D; Schneider, Mary L; Mukherjee, Jogeshwar; Christian, Bradley T

    2014-01-01

    4-trans-[18F]Mefway is a PET radiotracer with high affinity for 5-HT1A receptors. Our preliminary work indicated the positional isomer, 3-[18F]mefway, would be suitable for PET imaging of 5-HT1A receptors. We now compare the in vivo behaviour of 3-mefway with 4-mefway to evaluate 3-[18F]mefway as a potential 5-HT1A PET radiotracer. Two male rhesus macaques were given bolus injections of both 3- and 4-trans-[18F]mefway in separate experiments. 90 minute dynamic PET scans were acquired. TACs were extracted in the mesial temporal lobe (MTL) and caudal anterior cingulate gyrus (cACg). The cerebellum (CB) was used as a reference region. In vivo behavior of the radiotracers in the CB was compared based upon the ratio of normalized PET uptake for 3- and 4-trans-[18F]mefway. Specific binding was compared by examining MTL/CB and cACg/CB ratios. The subject-averaged ratio of 3-[18F]mefway to 4-trans-[18F]mefway in the cerebellum was 0.96 for 60-90 minutes. MTL/CB reached plateaus of ~2.7 and ~6 by 40 minutes and 90 minutes for 3- and 4-trans-[18F]mefway, respectively. cACg/CB reached plateaus of ~2.5 and ~6 by 40 minutes and 70 minutes for 3- and 4-trans-[18F]mefway, respectively. The short pseudoequilibration times and sufficient uptake of 3-[18F]mefway may be useful in studies requiring short scan times. Furthermore, the similar nondisplaceable clearance in the CB to 4-trans-[18F]mefway suggests the lower BPND of 3-[18F]mefway is due to a lower affinity. The lower affinity of 3-[18F]mefway may make it useful for measuring changes in endogenous 5-HT levels, however, this remains to be ascertained. PMID:25143866

  4. 18F-Positron Emitting/Trimethine Cyanine-Fluorescent Contrast for Image-Guided Prostate Cancer Management.

    PubMed

    Kommidi, Harikrishna; Guo, Hua; Nurili, Fuad; Vedvyas, Yogindra; Jin, Moonsoo M; McClure, Timothy D; Ehdaie, Behfar; Sayman, Haluk B; Akin, Oguz; Aras, Omer; Ting, Richard

    2018-05-10

    [ 18/19 F]-4, an anionic GCPII/PSMA inhibitor for image-guided intervention in prostate cancer, is described. [ 19 F]-4 is radiolabeled with a radiochemical yield that is ≥27% and a molar activity of 190 ± 50 mCi/μmol in a <1 h, one-step, aqueous isotopic exchange reaction. [ 19 F]-4 allows PSMA expression to be imaged by fluorescence (FL) and [ 18 F]-PET. PC3-PIP (PSMA-positive, EC 50 = 6.74 ± 1.33 nM) cancers are specifically delineated in mice that bear 3 million (18 mg) PC3-PIP and PC3 (control, PSMA-negative) cells. Colocalization of [ 18/19 F]-4 PET, fluorescence, scintillated biodistribution, and PSMA expression are observed.

  5. 18F-AV-1451 positron emission tomography in Alzheimer's disease and progressive supranuclear palsy.

    PubMed

    Passamonti, Luca; Vázquez Rodríguez, Patricia; Hong, Young T; Allinson, Kieren S J; Williamson, David; Borchert, Robin J; Sami, Saber; Cope, Thomas E; Bevan-Jones, W Richard; Jones, P Simon; Arnold, Robert; Surendranathan, Ajenthan; Mak, Elijah; Su, Li; Fryer, Tim D; Aigbirhio, Franklin I; O'Brien, John T; Rowe, James B

    2017-03-01

    The ability to assess the distribution and extent of tau pathology in Alzheimer's disease and progressive supranuclear palsy in vivo would help to develop biomarkers for these tauopathies and clinical trials of disease-modifying therapies. New radioligands for positron emission tomography have generated considerable interest, and controversy, in their potential as tau biomarkers. We assessed the radiotracer 18F-AV-1451 with positron emission tomography imaging to compare the distribution and intensity of tau pathology in 15 patients with Alzheimer's pathology (including amyloid-positive mild cognitive impairment), 19 patients with progressive supranuclear palsy, and 13 age- and sex-matched controls. Regional analysis of variance and a support vector machine were used to compare and discriminate the clinical groups, respectively. We also examined the 18F-AV-1451 autoradiographic binding in post-mortem tissue from patients with Alzheimer's disease, progressive supranuclear palsy, and a control case to assess the 18F-AV-1451 binding specificity to Alzheimer's and non-Alzheimer's tau pathology. There was increased 18F-AV-1451 binding in multiple regions in living patients with Alzheimer's disease and progressive supranuclear palsy relative to controls [main effect of group, F(2,41) = 17.5, P < 0.0001; region of interest × group interaction, F(2,68) = 7.5, P < 0.00001]. More specifically, 18F-AV-1451 binding was significantly increased in patients with Alzheimer's disease, relative to patients with progressive supranuclear palsy and with control subjects, in the hippocampus and in occipital, parietal, temporal, and frontal cortices (t's > 2.2, P's < 0.04). Conversely, in patients with progressive supranuclear palsy, relative to patients with Alzheimer's disease, 18F-AV-1451 binding was elevated in the midbrain (t = 2.1, P < 0.04); while patients with progressive supranuclear palsy showed, relative to controls, increased 18F-AV-1451 uptake in the putamen, pallidum

  6. Is (18)F-FDG PET really a promising marker for clinically relevant atherosclerosis?

    PubMed

    Brammen, Lindsay; Palumbo, Barbara; Lupattelli, Graziana; Sinzinger, Helmut

    2014-01-01

    Bural et al (2013), retrospectively investigated 143 subjects who received whole body fluorine-18-fluorodeoxyglucose- positron emission tomography ((18)F-FDG-PET) imaging for the assessment of non-cardiovascular diseases. They reported an increase of (18)F-FDG-positive lesions in various aortic segments, which increased with age, and were more pronounced in subjects being aged below 50 years as compared to those above 50. Bural et al also found the highest segmental (18)F-FDG-uptake in the descending thoracic aorta, but not in the abdominal aorta, where the majority of the most severe atherosclerotic lesions essentially appear. In addition, they did not appreciate any significant gender difference. Despite the severe limitation that no correlation to vascular disease, risk factors, or any clinical parameter was available, this report again raises the question as to what positive (18)F-FDG imaging really reflects and whether it will ever reach the great expectations. Conventional radiotracers revealed an excellent experimental correlation, as well as morphology. Uptake ratios of symptomatic lesion vs. contralateral unaffected side were comparable between (111)In-platelets, (123)I-LDL and (18)FFDG. There was also a mass strategic correlation, but no individual prediction of events at all. Due to better statistics, image quality and solution PET imaging of atherosclerosis holds great promise. However, correlations between various tracers and vascular wall characteristics (and staining methodologies) in 1% cholesterol fed rabbits reveal that (18)F-FDG is not always the best tracer. Vascular foam cell content is reflected by (111)In-HIG > (125)I-oxLp(a) > (18)F-FDG > (125)I-LDL (Brammen L, Palumbo B, Lupattelli G et al. Unpublished data). A close correlation to Framingham risk score is for example not helpful, as this score has a low predictive value of only 0.6. The available clinical correlations between (18)F-FDG-uptake and arterial wall characteristics are poor. For

  7. New Radiation Dosimetry Estimates for [18F]FLT based on Voxelized Phantoms.

    PubMed

    Mendes, B M; Ferreira, A V; Nascimento, L T C; Ferreira, S M Z M D; Silveira, M B; Silva, J B

    2018-04-25

    3'-Deoxy-3-[ 18 F]fluorothymidine, or [ 18 F]FLT, is a positron emission tomography (PET) tracer used in clinical studies for noninvasive assessment of proliferation activity in several types of cancer. Although the use of this PET tracer is expanding, to date, few studies concerning its dosimetry have been published. In this work, new [ 18 F]FLT dosimetry estimates are determined for human and mice using Monte Carlo simulations. Modern voxelized male and female phantoms and [ 18 F]FLT biokinetic data, both published by the ICRP, were used for simulations of human cases. For most human organs/tissues the absorbed doses were higher than those reported in ICRP Publication 128. An effective dose of 1.70E-02 mSv/MBq to the whole body was determined, which is 13.5% higher than the ICRP reference value. These new human dosimetry estimates obtained using more realistic human phantoms represent an advance in the knowledge of [ 18 F]FLT dosimetry. In addition, mice biokinetic data were obtained experimentally. These data and a previously developed voxelized mouse phantom were used for simulations of animal cases. Concerning animal dosimetry, absorbed doses for organs/tissues ranged from 4.47 ± 0.75 to 155.74 ± 59.36 mGy/MBq. The obtained set of organ/tissue radiation doses for healthy Swiss mice is a useful tool for application in animal experiment design.

  8. Dynamic 18F-FET PET in newly diagnosed astrocytic low-grade glioma identifies high-risk patients.

    PubMed

    Jansen, Nathalie L; Suchorska, Bogdana; Wenter, Vera; Eigenbrod, Sabina; Schmid-Tannwald, Christine; Zwergal, Andreas; Niyazi, Maximilian; Drexler, Mark; Bartenstein, Peter; Schnell, Oliver; Tonn, Jörg-Christian; Thon, Niklas; Kreth, Friedrich-Wilhelm; la Fougère, Christian

    2014-02-01

    Because the clinical course of low-grade gliomas in the individual adult patient varies considerably and is unpredictable, we investigated the prognostic value of dynamic (18)F-fluorethyltyrosine ((18)F-FET) PET in the early diagnosis of astrocytic low-grade glioma (World Health Organization grade II). Fifty-nine patients with newly diagnosed low-grade glioma and dynamic (18)F-FET PET before histopathologic assessment were retrospectively investigated. (18)F-FET PET analysis comprised a qualitative visual classification of lesions; assessment of the semiquantitative parameters maximal, mean, and total standardized uptake value as ratio to background and biologic tumor volume; and dynamic analysis of intratumoral (18)F-FET uptake over time (increasing vs. decreasing time-activity curves). The correlation between PET parameters and progression-free survival, overall survival, and time to malignant transformation was investigated. (18)F-FET uptake greater than the background level was found in 34 of 59 tumors. Dynamic (18)F-FET uptake analysis was available for 30 of these 34 patients. Increasing and decreasing time-activity curves were found in 18 and 12 patients, respectively. Neither the qualitative factor presence or absence of (18)F-FET uptake nor any of the semiquantitative uptake parameters significantly influenced clinical outcome. In contrast, decreasing time-activity curves in the kinetic analysis were highly prognostic for shorter progression-free survival and time to malignant transformation (P < 0.001). Absence of (18)F-FET uptake in newly diagnosed astrocytic low-grade glioma does not generally indicate an indolent disease course. Among the (18)F-FET-positive gliomas, decreasing time-activity curves in dynamic (18)F-FET PET constitute an unfavorable prognostic factor in astrocytic low-grade glioma and, by identifying high-risk patients, may ease treatment decisions.

  9. Identification of microRNAs regulating Escherichia coli F18 infection in Meishan weaned piglets.

    PubMed

    Wu, Zhengchang; Qin, Weiyun; Wu, Seng; Zhu, Guoqiang; Bao, Wenbin; Wu, Shenglong

    2016-11-03

    Escherichia coli F18 is mainly responsible for post-weaning diarrhea (PWD) in piglets. The molecular regulation of E. coli F18 resistance in Chinese domestic weaned piglets is still obscure. We used Meishan piglets as model animals to test their susceptibility to E. coli F18. Small RNA duodenal libraries were constructed for E. coli F18-sensitive and -resistant weaned piglets challenged with E. coli F18 and sequenced using Illumina Solexa high-throughput sequencing technology. Sequencing results showed that 3,475,231 and 37,198,259 clean reads were obtained, with 311 known miRNAs differently expressed in resistant and sensitive groups, respectively. Twenty-four miRNAs, including 15 up-regulated and 9 down-regulated, demonstrated more than a 2-fold differential expression between the F18-resistant and -sensitive piglets. Stem-loop RT-qPCR showed that miR-136, miR-196b, miR-499-5p and miR-218-3p significantly expressed in intestinal tissue (p < 0.05). KEGG pathway analysis for target genes revealed that differently expressed miRNAs were involved in infectious diseases, signal transduction and immune system pathways. Interestingly, the expression of miR-218-3p in intestinal tissue had a very significant negative correlation with target DLG5 (P < 0.01). Based on the expression correlation between miRNA and target genes analysis, we speculate that miR-218-3p targeting to DLG5, appears to be very promising candidate for miRNAs involved in response to E. coli F18 infection. The present study provides improved database information on pig miRNAs, better understanding of the genetic basis of E. coli F18 resistance in local Chinese pig breeds and lays a new foundation for identifying novel markers of E. coli F18 resistance. This article was reviewed by Neil R Smalheiser and Weixiong Zhang.

  10. Synthesis and preliminary PET imaging of 11C and 18F isotopologues of the ROS1/ALK inhibitor lorlatinib

    NASA Astrophysics Data System (ADS)

    Collier, Thomas Lee; Normandin, Marc D.; Stephenson, Nickeisha A.; Livni, Eli; Liang, Steven H.; Wooten, Dustin W.; Esfahani, Shadi A.; Stabin, Michael G.; Mahmood, Umar; Chen, Jianqing; Wang, Wei; Maresca, Kevin; Waterhouse, Rikki N.; El Fakhri, Georges; Richardson, Paul; Vasdev, Neil

    2017-06-01

    Lorlatinib (PF-06463922) is a next-generation small-molecule inhibitor of the orphan receptor tyrosine kinase c-ros oncogene 1 (ROS1), which has a kinase domain that is physiologically related to anaplastic lymphoma kinase (ALK), and is undergoing Phase I/II clinical trial investigations for non-small cell lung cancers. An early goal is to measure the concentrations of this drug in brain tumour lesions of lung cancer patients, as penetration of the blood-brain barrier is important for optimal therapeutic outcomes. Here we prepare both 11C- and 18F-isotopologues of lorlatinib to determine the biodistribution and whole-body dosimetry assessments by positron emission tomography (PET). Non-traditional radiolabelling strategies are employed to enable an automated multistep 11C-labelling process and an iodonium ylide-based radiofluorination. Carbon-11-labelled lorlatinib is routinely prepared with good radiochemical yields and shows reasonable tumour uptake in rodents. PET imaging in non-human primates confirms that this radiotracer has high brain permeability.

  11. 18F-FDG as an inflammation biomarker for imaging dengue virus infection and treatment response

    PubMed Central

    Watanabe, Satoru; Herr, Keira J.; Kalimuddin, Shirin; Tham, Jing Yang; Ong, Joanne; Reolo, Marie; Serrano, Raymond M.F.; Cheung, Yin Bun; Low, Jenny G.H.; Vasudevan, Subhash G.

    2017-01-01

    Development of antiviral therapy against acute viral diseases, such as dengue virus (DENV), suffers from the narrow window of viral load detection in serum during onset and clearance of infection and fever. We explored a biomarker approach using 18F-fluorodeoxyglucose (18F-FDG) PET in established mouse models for primary and antibody-dependent enhancement infection with DENV. 18F-FDG uptake was most prominent in the intestines and correlated with increased virus load and proinflammatory cytokines. Furthermore, a significant temporal trend in 18F-FDG uptake was seen in intestines and selected tissues over the time course of infection. Notably, 18F-FDG uptake and visualization by PET robustly differentiated treatment-naive groups from drug-treated groups as well as nonlethal from lethal infections with a clinical strain of DENV2. Thus, 18F-FDG may serve as a novel DENV infection–associated inflammation biomarker for assessing treatment response during therapeutic intervention trials. PMID:28469088

  12. TANKS 18 AND 19-F EQUIPMENT GROUT FILL MATERIAL EVALUATION AND RECOMMENDATIONS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stefanko, D.; Langton, C.

    The United States Department of Energy (US DOE) intends to remove Tanks 18-F and 19-F at the Savannah River Site (SRS) from service. The high-level waste (HLW) tanks have been isolated from the F-area Tank Farm (FTF) facilities and will be filled with cementitious grout for the purpose of: (1) physically stabilizing the empty volumes in the tanks, (2) limiting/eliminating vertical pathways from the surface to residual waste on the bottom of the tanks, (3) providing an intruder barrier, and (4) providing an alkaline, chemical reducing environment within the closure boundary to limit solubility of residual radionuclides. Bulk waste andmore » heel waste removal equipment will remain in Tanks 18-F and 19-F when the tanks are closed. This equipment includes: mixer pumps, transfer pumps, transfer jets, equipment support masts, sampling masts and dip tube assemblies. The current Tank 18-F and 19-F closure strategy is to grout the internal void spaces in this equipment to eliminate fast vertical pathways and slow water infiltration to the residual material on the tank floor. This report documents the results of laboratory testing performed to identify a grout formulation for filling the abandoned equipment in Tanks 18-F and 19-F. The objective of this work was to formulate a flowable grout for filling internal voids of equipment that will remain in Tanks 18-F and 19-F during the final closures. This work was requested by V. A. Chander, Tank Farm Closure Engineering, in HLW-TTR-2011-008. The scope for this task is provided in the Task Technical and Quality Assurance Plan (TTQAP), SRNL-RP-2011-00587. The specific objectives of this task were to: (1) Prepare and evaluate the SRR cooling coil grout identified in WSRC-STI-2008-00298 per the TTR for this work. The cooling coil grout is a mixture of BASF MasterFlow{reg_sign} 816 cable grout (67.67 wt. %), Grade 100 ground granulated blast furnace slag (7.52 wt. %) and water (24.81 wt. %); (2) Identify equipment grout placement

  13. Methods to Increase the Metabolic Stability of (18)F-Radiotracers.

    PubMed

    Kuchar, Manuela; Mamat, Constantin

    2015-09-03

    The majority of pharmaceuticals and other organic compounds incorporating radiotracers that are considered foreign to the body undergo metabolic changes in vivo. Metabolic degradation of these drugs is commonly caused by a system of enzymes of low substrate specificity requirement, which is present mainly in the liver, but drug metabolism may also take place in the kidneys or other organs. Thus, radiotracers and all other pharmaceuticals are faced with enormous challenges to maintain their stability in vivo highlighting the importance of their structure. Often in practice, such biologically active molecules exhibit these properties in vitro, but fail during in vivo studies due to obtaining an increased metabolism within minutes. Many pharmacologically and biologically interesting compounds never see application due to their lack of stability. One of the most important issues of radiotracers development based on fluorine-18 is the stability in vitro and in vivo. Sometimes, the metabolism of (18)F-radiotracers goes along with the cleavage of the C-F bond and with the rejection of [(18)F]fluoride mostly combined with high background and accumulation in the skeleton. This review deals with the impact of radiodefluorination and with approaches to stabilize the C-F bond to avoid the cleavage between fluorine and carbon.

  14. Efficacy of a single oral dose of a live bivalent E. coli vaccine against post-weaning diarrhea due to F4 and F18-positive enterotoxigenic E. coli.

    PubMed

    Nadeau, É; Fairbrother, J M; Zentek, J; Bélanger, L; Tremblay, D; Tremblay, C-L; Röhe, I; Vahjen, W; Brunelle, M; Hellmann, K; Cvejić, D; Brunner, B; Schneider, C; Bauer, K; Wolf, R; Hidalgo, Á

    2017-08-01

    F4- and F18-positive enterotoxigenic E. coli strains (F4-ETEC and F18-ETEC) are important causes of post-weaning diarrhea (PWD) in pigs. F4 (antigenic variant ac) and F18 (ab and ac) fimbriae are major antigens that play an important role in the early stages of infection. Herein, the efficacy of a live oral vaccine consisting of two non-pathogenic E. coli strains, one F4ac- and one F18ac-positive, was evaluated using F4ac-ETEC and F18ab-ETEC challenge models. A randomized, masked, placebo-controlled, block design, parallel-group confirmatory study with two different vaccination-challenge intervals (7 and 21 days) was conducted for each challenge model. The vaccine was administered in one dose, to ≥18-day-old piglets via drinking water. Efficacy was assessed by evaluating diarrhea, clinical observations, weight gain and fecal shedding of F4-ETEC or F18-ETEC. Anti-F4 and anti-F18 immunoglobulins in blood were measured. The vaccination resulted in significant reductions in clinical PWD and fecal shedding of F4-ETEC and F18-ETEC after the 7- and 21-day-post-vaccination heterologous challenges, except for after the 21-day-post-vaccination F4-ETEC challenge, when the clinical PWD was too mild to demonstrate efficacy. A significant reduction of mortality and weight loss by vaccination were observed following the F18-ETEC challenge. The 7-day protection was associated with induction of anti-F4 and anti-F18 IgM, whereas the 21-day protection was mainly associated with anti-F4 and anti-F18 IgA. The 7-day onset and 21-day duration of protection induced by this vaccine administered once in drinking water to pigs of at least 18days of age were confirmed by protection against F4-ETEC and F18-ETEC, and induction of F4 and F18-specific immunity. Cross protection of the vaccine against F18ab-E. coli was demonstrated for both the 7- and 21-day F18-ETEC challenges. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  15. Paraneoplastic syndromes: detection of malignant tumors using [(18)F]FDG-PET.

    PubMed

    Berner, U; Menzel, C; Rinne, D; Kriener, S; Hamscho, N; Döbert, N; Diehl, M; Kaufmann, R; Grünwald, F

    2003-06-01

    Paraneoplastic syndromes (PS) comprise a variety of clinical symptoms and diseases associated with underlying malignancy. Differentiation towards benign autoimmune diseases is necessary due to different therapeutic options. This diagnostic challenge includes cost- and time-consuming methods and is not successful in many cases. The aim of this study was the evaluation of [(18)F]fluorodeoxyglucose positron emission tomography ([(18)F]FDG-PET) for detecting or ruling out malignancy in these patients. In this retrospective work-up a total of 30 patients with suspected PS (m:f = 17:13, mean age 55, range 22-76 years) were examined with [(18)F]FDG-PET between 1996 and 2001. Diagnoses were erythrodermia, cerebellar degeneration, dermatomyositis, polyneuropathia and others. PET scans were compared to histopathological (n=14), radiological and follow up data (mean follow up 3.6 years, range 1-6 years). In 7 out of 30 patients (23%) an underlying malignancy was detected. Six out of 7 malignant neoplasms showed a distinctly increased glucose consumption. One benign neoplasm caused increased tracer uptake, another PET positive patient refused biopsy and showed no growth of a malignant tumour during clinical follow up of 28 months. The remaining 21 patients without suspicious glucose consumption did not demonstrate a malignancy in other diagnostic modalities or during subsequent clinical follow-up. [(18)F]FDG-PET seems to be a useful tool in the diagnostic work-up of patients with suspected paraneoplastic syndrome.

  16. Chronic manganism: A long-term follow-up study with a new dopamine terminal biomarker of 18F-FP-(+)-DTBZ (18F-AV-133) brain PET scan.

    PubMed

    Huang, Chu-Yun; Liu, Chi-Hung; Tsao, Eusden; Hsieh, Chia-Ju; Weng, Yi-Hsin; Hsiao, Ing-Tsung; Yen, Tzu-Chen; Lin, Kun-Ju; Huang, Chin-Chang

    2015-01-01

    Recent experimental studies revealed that dopamine neuron dysfunction in chronic manganism may be due to a reduced capacity of dopamine release in the striatum. The findings imposed further difficulty in the differential diagnosis between manganism and IPD. We conducted a long-term clinical follow-up study of 4 manganism patients, applying a new tracer (18)F-9-fluoropropyl-(+)-dihydrotetrabenazine ((18)F-AV-133) with positron emission tomography (PET). Twenty age-matched subjects including 4 manganism patients, 8 idiopathic Parkinson's disease (IPD) patients, and 8 healthy controls were enrolled for comparison. Volumes of interest of the bilateral putamen, caudate nuclei and occipital cortex as the reference region were delineated from individual magnetic resonance images. The clinical features of the manganism patients still progressed, with increased scores on the Unified Parkinson Disease Rating Scale. The (18)F-AV-133 uptake in the IPD patients decreased at the bilateral striatum, compared with the healthy controls. In the manganism patients, there was no decreased uptake of radioactivity involving the bilateral striatum, except Patient 4, who had a stroke with decreased uptake in the right posterior putamen. The (18)F-AV-133 PET finding reveals that nigrostriatum neurons are not degenerated in chronic manganism and can provide a useful neuroimage biomarker in the differential diagnosis. Copyright © 2015. Published by Elsevier B.V.

  17. Single-Cell Analysis of [18F]Fluorodeoxyglucose Uptake by Droplet Radiofluidics.

    PubMed

    Türkcan, Silvan; Nguyen, Julia; Vilalta, Marta; Shen, Bin; Chin, Frederick T; Pratx, Guillem; Abbyad, Paul

    2015-07-07

    Radiolabels can be used to detect small biomolecules with high sensitivity and specificity without interfering with the biochemical activity of the labeled molecule. For instance, the radiolabeled glucose analogue, [18F]fluorodeoxyglucose (FDG), is routinely used in positron emission tomography (PET) scans for cancer diagnosis, staging, and monitoring. However, despite their widespread usage, conventional radionuclide techniques are unable to measure the variability and modulation of FDG uptake in single cells. We present here a novel microfluidic technique, dubbed droplet radiofluidics, that can measure radiotracer uptake for single cells encapsulated into an array of microdroplets. The advantages of this approach are multiple. First, droplets can be quickly and easily positioned in a predetermined pattern for optimal imaging throughput. Second, droplet encapsulation reduces cell efflux as a confounding factor, because any effluxed radionuclide is trapped in the droplet. Last, multiplexed measurements can be performed using fluorescent labels. In this new approach, intracellular radiotracers are imaged on a conventional fluorescence microscope by capturing individual flashes of visible light that are produced as individual positrons, emitted during radioactive decay, traverse a scintillator plate placed below the cells. This method is used to measure the cell-to-cell heterogeneity in the uptake of tracers such as FDG in cell lines and cultured primary cells. The capacity of the platform to perform multiplexed measurements was demonstrated by measuring differential FDG uptake in single cells subjected to different incubation conditions and expressing different types of glucose transporters. This method opens many new avenues of research in basic cell biology and human disease by capturing the full range of stochastic variations in highly heterogeneous cell populations in a repeatable and high-throughput manner.

  18. STM study of C60F18 high dipole moment molecules on Au(111)

    NASA Astrophysics Data System (ADS)

    Bairagi, K.; Bellec, A.; Chumakov, R. G.; Menshikov, K. A.; Lagoute, J.; Chacon, C.; Girard, Y.; Rousset, S.; Repain, V.; Lebedev, A. M.; Sukhanov, L. P.; Svechnikov, N. Yu.; Stankevich, V. G.

    2015-11-01

    Scanning tunneling microscopy and spectroscopy studies of C60F18 molecules deposited on Au(111) are reported and compared to C60 molecules both at liquid helium temperature and room temperature (RT). Whereas adsorption and electronic properties of C60F18 single molecules were studied at low temperature (LT), self-assemblies were investigated at RT. In both cases, the fluorine atoms of the C60F18 molecules are pointed towards the surface. Individual C60F18 molecules on Au(111) have a HOMO-LUMO gap of 2.9 eV. The self-assembled islands exhibit a close-packed hexagonal lattice with amorphous borders. The comparison with C60 molecules clearly demonstrates the influence of the C60F18 electric dipole moment (EDM) on the electronic properties of single molecules and on the thermodynamics of self-assembled islands. Besides, the apparent height value of a separate molecule increases in a self-assembly environment as a result of a depolarization phenomenon.

  19. 18F-FDG PET/CT in detection of gynecomastia in patients with hepatocellular carcinoma.

    PubMed

    Wang, Hsin-Yi; Jeng, Long-Bin; Lin, Ming-Chia; Chao, Chih-Hao; Lin, Wan-Yu; Kao, Chia-Hung

    2013-01-01

    We retrospectively investigate the prevalence of gynecomastia as false-positive 2-[18F]fluoro-2-deoxy-d-glucose (18F-FDG) positron emission tomography (PET)/computed tomography (CT) imaging in patients with hepatocellular carcinoma (HCC). Among the 127 male HCC patients who underwent 18F-FDG PET/CT scan, the 18FDG uptakes at the bilateral breasts in 9 patients with gynecomastia were recorded as standard uptake value (SUVmax) and the visual interpretation in both early and delayed images. The mean early SUVmax was 1.58/1.57 (right/left breast) in nine gynecomastia patients. The three patients with early visual score of 3 had higher early SUVmaxs. Gynecomastia is a possible cause of false-positive uptake on 18F-FDG PET/CT images. Copyright © 2013 Elsevier Inc. All rights reserved.

  20. Imaging of adrenal incidentalomas with PET using (11)C-metomidate and (18)F-FDG.

    PubMed

    Minn, Heikki; Salonen, Anna; Friberg, Johan; Roivainen, Anne; Viljanen, Tapio; Långsjö, Jaakko; Salmi, Jorma; Välimäki, Matti; Någren, Kjell; Nuutila, Pirjo

    2004-06-01

    Our aim was to evaluate the use of PET with (11)C-metomidate and (18)F-FDG for the diagnosis of adrenal incidentalomas. Twenty-one patients underwent hormonal screening before dynamic imaging of the upper abdomen with (11)C-metomidate, and for 19 of these 21 patients, static (18)F-FDG imaging followed. Uptake of (11)C-metomidate and (18)F-FDG in incidentalomas was quantified and correlated with the hormonal work-up and the mass size on CT (median, 2.5 cm; range, 2-10 cm). The final diagnoses were hormonally active adenoma (n = 7), nonsecretory adenoma (n = 5), adrenocortical carcinoma (n = 1), pheochromocytoma (n = 2), benign noncortical tumor (n = 2), normal adrenal (n = 1), and malignant noncortical tumor (n = 3). Diagnosis was established at surgery (n = 9), percutaneous biopsy (n = 4), or follow-up (n = 8). The highest uptake of (11)C-metomidate, expressed as standardized uptake value (SUV), was found in adrenocortical carcinoma (SUV = 28.0), followed by active adenomas (median SUV = 12.7), nonsecretory adenomas (median SUV = 12.2), and noncortical tumors (median SUV = 5.7). Patients with adenomas had significantly higher tumor-to-normal-adrenal (11)C-metomidate SUV ratios than did patients with noncortical tumors. (18)F-FDG detected 2 of 3 noncortical malignancies but failed to detect adrenal metastases from renal cell carcinoma. All inactive and most active adenomas were difficult to detect with (18)F-FDG against background activity, whereas both pheochromocytomas and adrenocortical carcinoma showed slightly increased uptake of (18)F-FDG. There was no correlation between uptake of (11)C-metomidate or (18)F-FDG and mass size. (11)C-Metomidate is a promising PET tracer to identify incidentalomas of adrenocortical origin. (18)F-FDG should be reserved for patients with a moderate to high likelihood of neoplastic disease.

  1. 18F-FDG PET/CT in differentiating malignant from benign origins of obstructive jaundice.

    PubMed

    Wang, Shao-Bo; Wu, Hu-Bing; Wang, Quan-Shi; Zhou, Wen-Lan; Tian, Ying; Ji, Yun-Hai; Lv, Liang

    2015-10-01

    The various origins of obstructive jaundice make the diagnosis of the disease difficult. This study was undertaken to evaluate the role of 18F-FDG PET/CT in differentiating malignant from benign origins of obstructive jaundice and to quantify the added value of 18F-FDG PET/CT over conventional imaging (enhanced CT and/or MRI). Eighty-five patients with obstructive jaundice who underwent 18F-FDG PET/CT within 2 weeks after enhanced CT and/or MRI were reviewed retrospectively. All 18F-FDG PET/CT images were independently evaluated by 2 nuclear medicine physicians who were unaware of other imaging data; differences were resolved by consensus of the physicians. All conventional imaging interpretations, according to the medical records, were reviewed by 2 radiologists to determine the potential value. Final diagnoses were based on histological or surgical findings. Sixty-six patients were diagnosed with malignancies, and 19 patients with benign lesions. The maximum standardized uptake values for malignant and benign lesions causing biliary obstruction were 8.2+/-4.4 and 4.0+/-5.0, respectively (P<0.05). The sensitivity, specificity, and overall accuracy for differentiating malignant from benign origins with 18F-FDG PET/CT were 86.4% (57/66), 73.7% (14/19), and 83.5% (71/85), respectively. 18F-FDG PET/CT in conjunction with conventional imaging changed the sensitivity, specificity, and overall accuracy of conventional imaging alone from 75.8% (50/66) to 95.5% (63/66) (P<0.05), 68.4% (13/19) to 57.9% (11/19) (P>0.05), and 74.1% (63/85) to 87.1% (74/85) (P<0.05), respectively. 18F-FDG PET/CT is of great value in differentiating malignant from benign origins of obstructive jaundice and is a useful adjuvant to conventional imaging. 18F-FDG PET/CT should be recommended for further etiological clarification.

  2. Radiosynthesis of a new PSMA targeting ligand ([18F]FPy-DUPA-Pep).

    PubMed

    Malik, Noeen; Machulla, Hans-Jürgen; Solbach, Christoph; Winter, Gordon; Reske, Sven N; Zlatopolskiy, Boris

    2011-07-01

    Due to the specificity of expression of PSMA (prostate specific membrane antigen) particularly in prostate cancer cells (e.g. LNCaP), numerous PSMA ligands have been synthesized until now. In the current study, we synthesized DUPA-Pep having 2-[3-(1,3-dicarboxypropyl)ureido]pentanedioic acid (DUPA) linked via 8-aminooctanoic acid to two phenylalanine residues and chose 6-[(18)F]fluoronicotinic acid 2,3,5,6-tetrafluorophenyl ester [(18)F]FPy-TFP as a prosthetic group for coupling. [(18)F]FPy-DUPA-Pep was obtained in a radiochemical yield of 48±0.9% (decay uncorrected) within 50 min with a chemical purity of >98%. Copyright © 2011 Elsevier Ltd. All rights reserved.

  3. Demons versus Level-Set motion registration for coronary 18F-sodium fluoride PET.

    PubMed

    Rubeaux, Mathieu; Joshi, Nikhil; Dweck, Marc R; Fletcher, Alison; Motwani, Manish; Thomson, Louise E; Germano, Guido; Dey, Damini; Berman, Daniel S; Newby, David E; Slomka, Piotr J

    2016-02-27

    Ruptured coronary atherosclerotic plaques commonly cause acute myocardial infarction. It has been recently shown that active microcalcification in the coronary arteries, one of the features that characterizes vulnerable plaques at risk of rupture, can be imaged using cardiac gated 18 F-sodium fluoride ( 18 F-NaF) PET. We have shown in previous work that a motion correction technique applied to cardiac-gated 18 F-NaF PET images can enhance image quality and improve uptake estimates. In this study, we further investigated the applicability of different algorithms for registration of the coronary artery PET images. In particular, we aimed to compare demons vs. level-set nonlinear registration techniques applied for the correction of cardiac motion in coronary 18 F-NaF PET. To this end, fifteen patients underwent 18 F-NaF PET and prospective coronary CT angiography (CCTA). PET data were reconstructed in 10 ECG gated bins; subsequently these gated bins were registered using demons and level-set methods guided by the extracted coronary arteries from CCTA, to eliminate the effect of cardiac motion on PET images. Noise levels, target-to-background ratios (TBR) and global motion were compared to assess image quality. Compared to the reference standard of using only diastolic PET image (25% of the counts from PET acquisition), cardiac motion registration using either level-set or demons techniques almost halved image noise due to the use of counts from the full PET acquisition and increased TBR difference between 18 F-NaF positive and negative lesions. The demons method produces smoother deformation fields, exhibiting no singularities (which reflects how physically plausible the registration deformation is), as compared to the level-set method, which presents between 4 and 8% of singularities, depending on the coronary artery considered. In conclusion, the demons method produces smoother motion fields as compared to the level-set method, with a motion that is physiologically

  4. Demons versus level-set motion registration for coronary 18F-sodium fluoride PET

    NASA Astrophysics Data System (ADS)

    Rubeaux, Mathieu; Joshi, Nikhil; Dweck, Marc R.; Fletcher, Alison; Motwani, Manish; Thomson, Louise E.; Germano, Guido; Dey, Damini; Berman, Daniel S.; Newby, David E.; Slomka, Piotr J.

    2016-03-01

    Ruptured coronary atherosclerotic plaques commonly cause acute myocardial infarction. It has been recently shown that active microcalcification in the coronary arteries, one of the features that characterizes vulnerable plaques at risk of rupture, can be imaged using cardiac gated 18F-sodium fluoride (18F-NaF) PET. We have shown in previous work that a motion correction technique applied to cardiac-gated 18F-NaF PET images can enhance image quality and improve uptake estimates. In this study, we further investigated the applicability of different algorithms for registration of the coronary artery PET images. In particular, we aimed to compare demons vs. level-set nonlinear registration techniques applied for the correction of cardiac motion in coronary 18F-NaF PET. To this end, fifteen patients underwent 18F-NaF PET and prospective coronary CT angiography (CCTA). PET data were reconstructed in 10 ECG gated bins; subsequently these gated bins were registered using demons and level-set methods guided by the extracted coronary arteries from CCTA, to eliminate the effect of cardiac motion on PET images. Noise levels, target-to-background ratios (TBR) and global motion were compared to assess image quality. Compared to the reference standard of using only diastolic PET image (25% of the counts from PET acquisition), cardiac motion registration using either level-set or demons techniques almost halved image noise due to the use of counts from the full PET acquisition and increased TBR difference between 18F-NaF positive and negative lesions. The demons method produces smoother deformation fields, exhibiting no singularities (which reflects how physically plausible the registration deformation is), as compared to the level-set method, which presents between 4 and 8% of singularities, depending on the coronary artery considered. In conclusion, the demons method produces smoother motion fields as compared to the level-set method, with a motion that is physiologically

  5. A multidisciplinary study of 3-(β-d-glucopyranosyl)-5-substituted-1,2,4-triazole derivatives as glycogen phosphorylase inhibitors: Computation, synthesis, crystallography and kinetics reveal new potent inhibitors.

    PubMed

    Kun, Sándor; Begum, Jaida; Kyriakis, Efthimios; Stamati, Evgenia C V; Barkas, Thomas A; Szennyes, Eszter; Bokor, Éva; Szabó, Katalin E; Stravodimos, George A; Sipos, Ádám; Docsa, Tibor; Gergely, Pál; Moffatt, Colin; Patraskaki, Myrto S; Kokolaki, Maria C; Gkerdi, Alkistis; Skamnaki, Vassiliki T; Leonidas, Demetres D; Somsák, László; Hayes, Joseph M

    2018-03-10

    3-(β-d-Glucopyranosyl)-5-substituted-1,2,4-triazoles have been revealed as an effective scaffold for the development of potent glycogen phosphorylase (GP) inhibitors but with the potency very sensitive to the nature of the alkyl/aryl 5-substituent (Kun et al., Eur. J. Med. Chem. 2014, 76, 567). For a training set of these ligands, quantum mechanics-polarized ligand docking (QM-PLD) demonstrated good potential to identify larger differences in potencies (predictive index PI = 0.82) and potent inhibitors with K i 's < 10 μM (AU-ROC = 0.86). Accordingly, in silico screening of 2335 new analogues exploiting the ZINC docking database was performed and nine predicted candidates selected for synthesis. The compounds were prepared in O-perbenzoylated forms by either ring transformation of 5-β-d-glucopyranosyl tetrazole by N-benzyl-arenecarboximidoyl chlorides, ring closure of C-(β-d-glucopyranosyl)formamidrazone with aroyl chlorides, or that of N-(β-d-glucopyranosylcarbonyl)arenethiocarboxamides by hydrazine, followed by deprotections. Kinetics experiments against rabbit muscle GPb (rmGPb) and human liver GPa (hlGPa) revealed five compounds as potent low μM inhibitors with three of these on the submicromolar range for rmGPa. X-ray crystallographic analysis sourced the potency to a combination of favorable interactions from the 1,2,4-triazole and suitable aryl substituents in the GP catalytic site. The compounds also revealed promising calculated pharmacokinetic profiles. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  6. In vivo PET imaging of beta-amyloid deposition in mouse models of Alzheimer's disease with a high specific activity PET imaging agent [18F]flutemetamol

    PubMed Central

    2014-01-01

    Background The purpose of the study was to evaluate the applicability of 18F-labelled amyloid imaging positron emission tomography (PET) agent [18F]flutemetamol to detect changes in brain beta-amyloid (Aβ) deposition in vivo in APP23, Tg2576 and APPswe-PS1dE9 mouse models of Alzheimer's disease. We expected that the high specific activity of [18F]flutemetamol would make it an attractive small animal Aβ imaging agent. Methods [18F]flutemetamol uptake in the mouse brain was evaluated in vivo at 9 to 22 months of age with an Inveon Multimodality PET/CT camera (Siemens Medical Solutions USA, Knoxville, TN, USA). Retention in the frontal cortex (FC) was evaluated by Logan distribution volume ratios (DVR) and FC/cerebellum (CB) ratios during the late washout phase (50 to 60 min). [18F]flutemetamol binding to Aβ was also evaluated in brain slices by in vitro and ex vivo autoradiography. The amount of Aβ in the brain slices was determined with Thioflavin S and anti-Aβ1−40 immunohistochemistry. Results In APP23 mice, [18F]flutemetamol retention in the FC increased from 9 to 18 months. In younger mice, DVR and FC/CB50-60 were 0.88 (0.81) and 0.88 (0.89) at 9 months (N = 2), and 0.98 (0.93) at 12 months (N = 1), respectively. In older mice, DVR and FC/CB50-60 were 1.16 (1.15) at 15 months (N = 1), 1.13 (1.16) and 1.35 (1.35) at 18 months (N = 2), and 1.05 (1.31) at 21 months (N = 1). In Tg2576 mice, DVR and FC/CB50-60 showed modest increasing trends but also high variability. In APPswe-PS1dE9 mice, DVR and FC/CB50-60 did not increase with age. Thioflavin S and anti-Aβ1−40 positive Aβ deposits were present in all transgenic mice at 19 to 22 months, and they co-localized with [18F]flutemetamol binding in the brain slices examined with in vitro and ex vivo autoradiography. Conclusions Increased [18F]flutemetamol retention in the brain was detected in old APP23 mice in vivo. However, the high specific activity of [18F]flutemetamol did not

  7. Biodistribution and radiation dosimetry of 18F-CP-18, a potential apoptosis imaging agent, as determined from PET/CT scans in healthy volunteers.

    PubMed

    Doss, Mohan; Kolb, Hartmuth C; Walsh, Joseph C; Mocharla, Vani; Fan, Hong; Chaudhary, Ashok; Zhu, Zhihong; Alpaugh, R Katherine; Lango, Miriam N; Yu, Jian Q

    2013-12-01

    (18)F-CP-18, or (18S,21S,24S,27S,30S)-27-(2-carboxyethyl)-21-(carboxymethyl)-30-((2S,3R,4R,5R,6S)-6-((2-(4-(3-F18-fluoropropyl)-1H-1,2,3-triazol-1-yl)acetamido)methyl)-3,4,5-trihydroxytetrahydro-2H-pyran-2-carboxamido)-24-isopropyl-18-methyl-17,20,23,26,29-pentaoxo-4,7,10,13-tetraoxa-16,19,22,25,28-pentaazadotriacontane-1,32-dioic acid, is being evaluated as a tissue apoptosis marker for PET imaging. The purpose of this study was to determine the biodistribution and estimate the normal-organ radiation-absorbed doses and effective dose from (18)F-CP-18. Successive whole-body PET/CT scans were obtained at approximately 7, 45, 90, 130, and 170 min after intravenous injection of (18)F-CP-18 in 7 healthy human volunteers. Blood samples and urine were collected between the PET/CT scans, and the biostability of (18)F-CP-18 was assessed using high-performance liquid chromatography. The PET scans were analyzed to determine the radiotracer uptake in different organs. OLINDA/EXM software was used to calculate human radiation doses based on the biodistribution of the tracer. (18)F-CP-18 was 54% intact in human blood at 135 min after injection. The tracer cleared rapidly from the blood pool with a half-life of approximately 30 min. Relatively high (18)F-CP-18 uptake was observed in the kidneys and bladder, with diffuse uptake in the liver and heart. The mean standardized uptake values (SUVs) in the bladder, kidneys, heart, and liver at around 50 min after injection were approximately 65, 6, 1.5, and 1.5, respectively. The calculated effective dose was 38 ± 4 μSv/MBq, with the urinary bladder wall having the highest absorbed dose at 536 ± 61 μGy/MBq using a 4.8-h bladder-voiding interval for the male phantom. For a 1-h voiding interval, these doses were reduced to 15 ± 2 μSv/MBq and 142 ± 15 μGy/MBq, respectively. For a typical injected activity of 555 MBq, the effective dose would be 21.1 ± 2.2 mSv for the 4.8-h interval, reduced to 8.3 ± 1.1 mSv for the 1-h interval

  8. Detection of bladder metabolic artifacts in (18)F-FDG PET imaging.

    PubMed

    Roman-Jimenez, Geoffrey; Crevoisier, Renaud De; Leseur, Julie; Devillers, Anne; Ospina, Juan David; Simon, Antoine; Terve, Pierre; Acosta, Oscar

    2016-04-01

    Positron emission tomography using (18)F-fluorodeoxyglucose ((18)F-FDG-PET) is a widely used imaging modality in oncology. It enables significant functional information to be included in analyses of anatomical data provided by other image modalities. Although PET offers high sensitivity in detecting suspected malignant metabolism, (18)F-FDG uptake is not tumor-specific and can also be fixed in surrounding healthy tissue, which may consequently be mistaken as cancerous. PET analyses may be particularly hampered in pelvic-located cancers by the bladder׳s physiological uptake potentially obliterating the tumor uptake. In this paper, we propose a novel method for detecting (18)F-FDG bladder artifacts based on a multi-feature double-step classification approach. Using two manually defined seeds (tumor and bladder), the method consists of a semi-automated double-step clustering strategy that simultaneously takes into consideration standard uptake values (SUV) on PET, Hounsfield values on computed tomography (CT), and the distance to the seeds. This method was performed on 52 PET/CT images from patients treated for locally advanced cervical cancer. Manual delineations of the bladder on CT images were used in order to evaluate bladder uptake detection capability. Tumor preservation was evaluated using a manual segmentation of the tumor, with a threshold of 42% of the maximal uptake within the tumor. Robustness was assessed by randomly selecting different initial seeds. The classification averages were 0.94±0.09 for sensitivity, 0.98±0.01 specificity, and 0.98±0.01 accuracy. These results suggest that this method is able to detect most (18)F-FDG bladder metabolism artifacts while preserving tumor uptake, and could thus be used as a pre-processing step for further non-parasitized PET analyses. Copyright © 2016. Published by Elsevier Ltd.

  9. Dose-on-demand production of diverse 18F-radiotracers for preclinical applications using a continuous flow microfluidic system.

    PubMed

    Matesic, Lidia; Kallinen, Annukka; Greguric, Ivan; Pascali, Giancarlo

    2017-09-01

    The production of 18 F-radiotracers using continuous flow microfluidics is under-utilized due to perceived equipment limitations. We describe the dose-on-demand principle, whereby the back-to-back production of multiple, diverse 18 F-radiotracers can be prepared on the same day, on the same microfluidic system using the same batch of [ 18 F]fluoride, the same microreactor, the same HPLC column and SPE cartridge to obtain a useful production yield. [ 18 F]MEL050, [ 18 F]Fallypride and [ 18 F]PBR111 were radiolabeled with [ 18 F]fluoride using the Advion NanoTek Microfluidic Synthesis System. The outlet of the microreactor was connected to an automated HPLC injector and following the collection of the product, SPE reformulation produced the 18 F-radiotracer in <10% ethanolic saline. A thorough automated cleaning procedure was implemented to ensure no cross-contamination between radiotracer synthesis. The complete productions for [ 18 F]MEL050 and [ 18 F]Fallypride were performed at total flow rates of 20μL/min, resulting in 40±13% and 25±13% RCY respectively. [ 18 F]PBR111 was performed at 200μL/min to obtain 27±8% RCY. Molar activities for each 18 F-radiotracer were >100GBq/μmol and radiochemical purities were >97%, implying that the cleaning procedure was effective. Using the same initial solution of [ 18 F]fluoride, microreactor, HPLC column and SPE cartridge, three diverse 18 F-radiotracers could be produced in yields sufficient for preclinical studies in a back-to-back fashion using a microfluidic system with no detectable cross-contamination. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  10. Use of micro-positron emission tomography with (18)F-fallypride to measure the levels of dopamine receptor-D2 and (18)F-FDG as molecular imaging tracer in the pituitary glands and prolactinomas of Fischer-344 rats.

    PubMed

    Li, Ping; Gui, Songbai; Cao, Lei; Gao, Hua; Bai, Jiwei; Li, Chuzhong; Zhang, Yazhuo

    2016-01-01

    Dopamine receptor-D2 (DRD2) is the most important drug target in prolactinoma. The aim of this current study was to investigate the role of using micro-positron emission tomography (micro-PET) with (18)F-fallypride and (18)F-fluorodeoxyglucose ((18)F-FDG) as molecular imaging tracer in the pituitary glands and prolactinomas of Fischer-344 (F344) rats and detect the difference of the levels of DRD2 in the pituitary glands and prolactinomas of F344 rat prolactinoma models. Female F344 rat prolactinoma models were established by subcutaneous administration of 15 mg 17β-estradiol for 8 weeks. The growth of tumors was monitored by the small-animal magnetic resonance imaging and micro-PET. A series of molecular biological experiments were also performed 4 and 6 weeks after pump implantation. The micro-PET molecular imaging with (18)F-fallypride revealed a decreased expression of DRD2 in F344 rat prolactinoma models, but the micro-PET molecular imaging with (18)F-FDG presented an increased uptake in the prolactinoma compared with the pituitary gland. A decreasing trend of levels of DRD2 in F344 rat prolactinoma models was also detected by molecular biological experiments. From this, we can conclude that micro-PET with (18)F-fallypride and (18)F-FDG can be used to assess tumorigenesis of the prolactinomas in vivo and molecular imaging detection of DRD2 level in prolactinoma may be an indication of treatment effect in the animal experiment.

  11. Is the detection rate of 18F-choline PET/CT influenced by androgen-deprivation therapy?

    PubMed

    Chondrogiannis, Sotirios; Marzola, Maria Cristina; Ferretti, Alice; Grassetto, Gaia; Maffione, Anna Margherita; Rampin, Lucia; Fanti, Stefano; Giammarile, Francesco; Rubello, Domenico

    2014-07-01

    To evaluate if the detection rate (DR) of (18)F-choline (18F-CH) PET/CT is influenced by androgen-deprivation therapy (ADT) in patients with prostate cancer (PC) already treated with radical intent and presenting biochemical relapse. We have retrospectively evaluated (18)F-CH PET/CT scans of 325 consecutive PC patients enrolled in the period November 2009 to December 2012 previously treated with radical intent and referred to our centre to perform (18)F-CH PET/CT for biochemical relapse. Two different groups of patients were evaluated. group A included the whole sample of 325 patients (mean age 70 years, range: 49-86) who presented trigger PSA between 0.1 and 80 ng/ml (mean 5.5 ng/ml), and group B included 187 patients (mean age 70 years, range 49-86) with medium-low levels of trigger PSA ranging between 0.5 and 5 ng/ml (mean PSA 2.1 ng/ml); group B was chosen in order to obtain a more homogeneous group of patients in terms of PSA values also excluding both very low and very high PSA levels avoiding the "a priori" higher probability of negative or positive PET scan, respectively. At the time of examination, 139 patients from group A and 72 patients from group B were under ADT: these patients were considered to be hormone-resistant PC patients because from their oncologic history (>18 months) an increase of PSA levels emerged despite the ongoing ADT. The relationship between (18)F-CH PET/CT findings and possible clinical predictors was investigated using both univariate and multivariate binary logistic regression analyses, including trigger PSA and ADT. Considering the whole population, overall DR of (18)F-CH PET was 58.2 % (189/325 patients). In the whole sample of patients (group A), both at the univariate and multivariate logistic regression analysis, trigger PSA and ADT were significantly correlated with the DR of (18)F-CH PET (p < 0.05). Moreover, the DR in patients under ADT (mean PSA 7.8 ng/ml) was higher than in patients not under ADT (mean PSA 3.9 ng

  12. A Prospective Study Comparing 99mTc-Hydroxyethylene-Diphosphonate Planar Bone Scintigraphy and Whole-Body SPECT/CT with 18F-Fluoride PET/CT and 18F-Fluoride PET/MRI for Diagnosing Bone Metastases.

    PubMed

    Löfgren, Johan; Mortensen, Jann; Rasmussen, Sine H; Madsen, Claus; Loft, Annika; Hansen, Adam E; Oturai, Peter; Jensen, Karl Erik; Mørk, Mette Louise; Reichkendler, Michala; Højgaard, Liselotte; Fischer, Barbara M

    2017-11-01

    We prospectively evaluated and compared the diagnostic performance of 99m Tc-hydroxyethylene-diphosphonate ( 99m Tc-HDP) planar bone scintigraphy (pBS), 99m Tc-HDP SPECT/CT, 18 F-NaF PET/CT, and 18 F-NaF PET/MRI for the detection of bone metastases. Methods: One hundred seventeen patients with histologically proven malignancy referred for clinical pBS were prospectively enrolled. pBS and whole-body SPECT/CT were performed followed by 18 F-NaF PET/CT within 9 d. 18 F-NaF PET/MRI was also performed in 46 patients. Results: Bone metastases were confirmed in 16 patients and excluded in 101, which was lower than expected. The number of equivocal scans was significantly higher for pBS than for SPECT/CT and PET/CT (18 vs. 5 and 6, respectively; P = 0.004 and 0.01, respectively). When equivocal readings were excluded, no statistically significant difference in sensitivity, specificity, positive predictive value, negative predictive value, or overall accuracy were found when comparing the different imaging techniques. In the per-patient analysis, equivocal scans were either assumed positive for metastases ("pessimistic analysis") or assumed negative for metastases ("optimistic analysis"). The percentages of misdiagnosed patients for the pessimistic analysis were 21%, 15%, 9%, and 7% for pBS, SPECT/CT, PET/CT, and PET/MRI, respectively. Corresponding figures for the optimistic analysis were 9%, 12%, 5%, and 7%. In those patients identified as having bone metastases according to the reference standard, SPECT/CT, 18 F-NaF PET/CT, and PET/MRI detected additional lesions compared with pBS in 31%, 63%, and 71%, respectively. Conclusion: 18 F-NaF PET/CT and whole-body SPECT/CT resulted in a significant reduction of equivocal readings compared with pBS, which implies an improved diagnostic confidence. However, the clinical benefit of using, for example, 18 F-NaF PET/CT or PET/MRI as compared with SPECT/CT and pBS in this patient population with a relatively low prevalence of bone

  13. Cancer Localization in the Prostate with F-18 Fluorocholine Positron Emission Tomography. Addendum

    DTIC Science & Technology

    2010-01-01

    of malignancy in anatomical sextants of the prostate gland. The rationale for evaluating fluorocholine as an oncologic tracer applicable to...interest in radiolabeled choline deriv- atives as oncologic tracers for positron emission tomogra- phy (PET) [6, 7]. This approach has shown feasibility in...prostate cancer using the tracer fluorine-18 fluor- omethylcholine (18F-choline) [8–11]. As a preliminary step in evaluating 18F-choline PET/CT as a

  14. Estimation of paclitaxel biodistribution and uptake in human-derived xenografts in vivo with (18)F-fluoropaclitaxel.

    PubMed

    Gangloff, Anne; Hsueh, Wei-Ann; Kesner, Amanda L; Kiesewetter, Dale O; Pio, Betty S; Pegram, Mark D; Beryt, Malgorzata; Townsend, Allison; Czernin, Johannes; Phelps, Michael E; Silverman, Daniel H S

    2005-11-01

    Paclitaxel (PAC) is widely used as a chemotherapy drug in the treatment of various malignancies, including breast, ovarian, and lung cancers. We examined the biodistribution of (18)F-fluoropaclitaxel ((18)F-FPAC) in mice with and without human breast cancer tumor xenografts by use of small-animal-dedicated PET (microPET) and clinically practical semiquantitative methods. We compared the PET data to data derived from direct harvesting and analysis of blood, organs, and breast carcinoma xenografts. PET data were acquired after tail vein injection of (18)F-FPAC in nude mice. Tracer biodistribution in reconstructed images was quantified by region-of-interest analysis. Biodistribution also was assessed by harvesting and analysis of dissected organs, tumors, and blood after coadministration of (18)F-FPAC and (3)H-PAC. (18)F content in each tissue was assessed with a gamma-well counter, and (3)H content was quantified by scintillation counting of solubilized tissue after (18)F radioactive decay. The distributions of (18)F-FPAC and (3)H-PAC were very similar, with the highest concentrations in the small intestine, the lowest concentrations in the brain, and intermediate concentrations in tumor. Uptake in these and other tissues was not inhibited by the presence of more pharmacologic doses of unlabeled PAC. Administration of the P-glycoprotein modulator cyclosporine doubled the uptake of both (18)F-FPAC and (3)H-PAC into tumor. PET studies with (18)F-FPAC can be used in conjunction with clinically practical quantification methods to yield estimates of PAC uptake in breast cancer tumors and normal organs noninvasively.

  15. (18)F-FDG uptake predicts diagnostic yield of transbronchial biopsy in peripheral lung cancer.

    PubMed

    Umeda, Yukihiro; Demura, Yoshiki; Anzai, Masaki; Matsuoka, Hiroki; Araya, Tomoyuki; Nishitsuji, Masaru; Nishi, Koichi; Tsuchida, Tatsuro; Sumida, Yasuyuki; Morikawa, Miwa; Ameshima, Shingo; Ishizaki, Takeshi; Kasahara, Kazuo; Ishizuka, Tamotsu

    2014-07-01

    Recent advances in endobronchial ultrasonography with a guide sheath (EBUS-GS) have enabled better visualization of distal airways, while virtual bronchoscopic navigation (VBN) has been shown useful as a guide to navigate the bronchoscope. However, indications for utilizing VBN and EBUS-GS are not always clear. To clarify indications for a bronchoscopic examination using VBN and EBUS-GS, we evaluated factors that predict the diagnostic yield of a transbronchial biopsy (TBB) procedure for peripheral lung cancer (PLC) lesions. We retrospectively reviewed the charts of 194 patients with 201 PLC lesions (≤3cm mean diameter), and analyzed the association of diagnostic yield of TBB with [(18)F]-fluoro-2-deoxy-d-glucose ((18)F-FDG) positron emission tomography and chest computed tomography (CT) findings. The diagnostic yield of TBB using VBN and EBUS-GS was 66.7%. High maximum standardized uptake value (SUVmax), positive bronchus sign, and ground-glass opacity component shown on CT were all significant predictors of diagnostic yield, while multivariate analysis showed only high (18)F-FDG uptake (SUVmax ≥2.8) and positive bronchus sign as significant predictors. Diagnostic yield was higher for PLC lesions with high (18)F-FDG uptake (SUVmax ≥2.8) and positive bronchus sign (84.6%) than for those with SUVmax <2.8 and negative bronchus sign (33.3%). High (18)F-FDG uptake was also correlated with tumor invasiveness. High (18)F-FDG uptake predicted the diagnostic yield of TBB using VBN and EBUS-GS for PLC lesions. (18)F-FDG uptake and bronchus sign may indicate for the accurate application of bronchoscopy with those modalities for diagnosing PLC. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  16. 18F-Labelled catecholamine type radiopharmaceuticals in the diagnosis of neurodegenerative diseases and neuroendocrine tumours: approaches to synthesis and development prospects

    NASA Astrophysics Data System (ADS)

    Vatsadze, S. Z.; Eremina, O. E.; Veselova, I. A.; Kalmykov, S. N.; Nenajdenko, V. G.

    2018-04-01

    The pathogenesis of many socially significant diseases such as neurodegenerative dementias and neuroendocrine tumours involves imbalance of neurotransmitters. Among the known neuroimaging methods, positron emission tomography (PET) is the most perfect and informative technique for diagnosing these diseases. The potential of PET is largely determined by the inventory of available radiopharmaceuticals, that is, biologically active molecules containing short-lived nuclides with positron decay. This review gives a systematic account of the application of fluorine-18-labelled catecholamine type radiopharmaceuticals in clinical investigations of the sympathetic and central nervous systems. The methods for the synthesis of these agents and existing problems are considered. The material is arranged according to the mechanisms of reactions that underlie the synthetic approaches: electrophilic, nucleophilic and metal-catalyzed reactions. The bibliography includes 198 references.

  17. Is integrated 18F-FDG PET/MRI superior to 18F-FDG PET/CT in the differentiation of incidental tracer uptake in the head and neck area?

    PubMed

    Schaarschmidt, Benedikt Michael; Gomez, Benedikt; Buchbender, Christian; Grueneisen, Johannes; Nensa, Felix; Sawicki, Lino Morris; Ruhlmann, Verena; Wetter, Axel; Antoch, Gerald; Heusch, Philipp

    2017-01-01

    We aimed to investigate the accuracy of 18F-fluorodeoxyglucose positron emission tomography/magnetic resonance imaging (18F-FDG PET/MRI) compared with contrast-enhanced 18F-FDG PET/computed tomography (PET/CT) for the characterization of incidental tracer uptake in examinations of the head and neck. A retrospective analysis of 81 oncologic patients who underwent contrast-enhanced 18F-FDG PET/CT and subsequent PET/MRI was performed by two readers for incidental tracer uptake. In a consensus reading, discrepancies were resolved. Each finding was either characterized as most likely benign, most likely malignant, or indeterminate. Using all available clinical information including results from histopathologic sampling and follow-up examinations, an expert reader classified each finding as benign or malignant. McNemar's test was used to compare the performance of both imaging modalities in characterizing incidental tracer uptake. Forty-six lesions were detected by both modalities. On PET/CT, 27 lesions were classified as most likely benign, one as most likely malignant, and 18 as indeterminate; on PET/MRI, 31 lesions were classified as most likely benign, one lesion as most likely malignant, and 14 as indeterminate. Forty-three lesions were benign and one lesion was malignant according to the reference standard. In two lesions, a definite diagnosis was not possible. McNemar's test detected no differences concerning the correct classification of incidental tracer uptake between PET/CT and PET/MRI (P = 0.125). In examinations of the head and neck area, incidental tracer uptake cannot be classified more accurately by PET/MRI than by PET/CT.

  18. A first-in-man PET study of [18F]PSS232, a fluorinated ABP688 derivative for imaging metabotropic glutamate receptor subtype 5.

    PubMed

    Warnock, Geoffrey; Sommerauer, Michael; Mu, Linjing; Pla Gonzalez, Gloria; Geistlich, Susanne; Treyer, Valerie; Schibli, Roger; Buck, Alfred; Krämer, Stefanie D; Ametamey, Simon M

    2018-06-01

    Non-invasive imaging of metabotropic glutamate receptor 5 (mGlu 5 ) in the brain using PET is of interest in e.g., anxiety, depression, and Parkinson's disease. Widespread application of the most widely used mGlu 5 tracer, [ 11 C]ABP688, is limited by the short physical half-life of carbon-11. [ 18 F]PSS232 is a fluorinated analog with promising preclinical properties and high selectivity and specificity for mGlu 5 . In this first-in-man study, we evaluated the brain uptake pattern and kinetics of [ 18 F]PSS232 in healthy volunteers. [ 18 F]PSS232 PET was performed with ten healthy male volunteers aged 20-40 years. Seven of the subjects received a bolus injection and the remainder a bolus/infusion protocol. Cerebral blood flow was determined in seven subjects using [ 15 O]water PET. Arterial blood activity was measured using an online blood counter. Tracer kinetics were evaluated by compartment modeling and parametric maps were generated for both tracers. At 90 min post-injection, 59.2 ± 11.1% of total radioactivity in plasma corresponded to intact tracer. The regional first pass extraction fraction of [ 18 F]PSS232 ranged from 0.41 ± 0.06 to 0.55 ± 0.03 and brain distribution pattern matched that of [ 11 C]ABP688. Uptake kinetics followed a simple two-tissue compartment model. The volume of distribution of total tracer (V T , ml/cm 3 ) ranged from 1.18 ± 0.20 for white matter to 2.91 ± 0.51 for putamen. The respective mean distribution volume ratios (DVR) with cerebellum as the reference tissue were 0.88 ± 0.06 and 2.12 ± 0.10, respectively. The tissue/cerebellum ratios of a bolus/infusion protocol (30/70 dose ratio) were close to the DVR values. Brain uptake of [ 18 F]PSS232 matched the distribution of mGlu 5 and followed a two-tissue compartment model. The well-defined kinetics and the possibility to use reference tissue models, obviating the need for arterial blood sampling, make [ 18 F]PSS232 a promising fluorine-18 labeled

  19. Positron Emission Tomography With 18F-Fluorodeoxyglucose in Patients With Sickle Cell Acute Chest Syndrome

    PubMed Central

    de Prost, Nicolas; Sasanelli, Myriam; Deux, Jean-François; Habibi, Anoosha; Razazi, Keyvan; Galactéros, Frédéric; Meignan, Michel; Maître, Bernard; Brun-Buisson, Christian; Itti, Emmanuel; Dessap, Armand Mekontso

    2015-01-01

    Abstract The acute chest syndrome (ACS) is the main cause of mortality among adult patients with sickle cell disease (SCD). Its pathophysiology is still unclear. Using positron emission tomography (PET) with 18F-fluorodeoxyglucose [18F-fluorodeoxyglucose (18F-FDG)], we explored the relationship between regional lung density and lung metabolism, as a reflection of lung neutrophilic infiltration during ACS. Patients were prospectively enrolled in a single-center study. Dual modality chest PET/computed tomography (CT) scans were performed, with 18F-FDG emission scans for quantification of regional 18F-FDG uptake and CT scans with radiocontrast agent to check for pulmonary artery thrombosis. Regional lung 18F-FDG uptake was quantified in ACS patients and in SCD patients without ACS (SCD non-ACS controls). Maximal (SUVmax) and mean (SUVmean) standardized uptake values were computed. Seventeen patients with ACS (mean age 28.3 ± 6.4 years) were included. None died nor required invasive mechanical ventilation. The main lung opacity on CT scans was lower lobe consolidation. Lungs of patients with ACS exhibited higher SUVmax than those of SCD non-ACS controls (2.5 [2.1–2.9] vs 0.8 [0.6–1.0]; P < 0.0001). Regional SUVmax and SUVmean was higher in lower than in upper lobes of ACS patients (P < 0.001) with a significant correlation between lung density and SUVmax (R2 = 0.78). SUVmean was higher in upper lobes of ACS patients than in lungs of SCD non-ACS controls (P < 0.001). Patients with SUVmax >2.5 had longer intensive care unit (ICU) stay than others (7 [6–11] vs 4 [3–6] days; P = 0.016). Lungs of patients with ACS exhibited higher 18F-FDG uptake than SCD non-ACS controls. Lung apices had normal aeration and lower 18F-FDG uptake than lung bases, but higher 18F-FDG uptake than lungs of SCD non-ACS controls. Patients with higher lung 18F-FDG uptake had longer ICU stay than others. PMID:25950690

  20. Ex vivo 18O-labeling mass spectrometry identifies a peripheral amyloid β clearance pathway.

    PubMed

    Portelius, Erik; Mattsson, Niklas; Pannee, Josef; Zetterberg, Henrik; Gisslén, Magnus; Vanderstichele, Hugo; Gkanatsiou, Eleni; Crespi, Gabriela A N; Parker, Michael W; Miles, Luke A; Gobom, Johan; Blennow, Kaj

    2017-02-20

    Proteolytic degradation of amyloid β (Aβ) peptides has been intensely studied due to the central role of Aβ in Alzheimer's disease (AD) pathogenesis. While several enzymes have been shown to degrade Aβ peptides, the main pathway of Aβ degradation in vivo is unknown. Cerebrospinal fluid (CSF) Aβ42 is reduced in AD, reflecting aggregation and deposition in the brain, but low CSF Aβ42 is, for unknown reasons, also found in some inflammatory brain disorders such as bacterial meningitis. Using 18 O-labeling mass spectrometry and immune-affinity purification, we examined endogenous proteolytic processing of Aβ in human CSF. The Aβ peptide profile was stable in CSF samples from healthy controls but in CSF samples from patients with bacterial meningitis, showing increased leukocyte cell count, 18 O-labeling mass spectrometry identified proteolytic activities degrading Aβ into several short fragments, including abundant Aβ1-19 and 1-20. After antibiotic treatment, no degradation of Aβ was detected. In vitro experiments located the source of the proteolytic activity to blood components, including leukocytes and erythrocytes, with insulin-degrading enzyme as the likely protease. A recombinant version of the mid-domain anti-Aβ antibody solanezumab was found to inhibit insulin-degrading enzyme-mediated Aβ degradation. 18 O labeling-mass spectrometry can be used to detect endogenous proteolytic activity in human CSF. Using this technique, we found an enzymatic activity that was identified as insulin-degrading enzyme that cleaves Aβ in the mid-domain of the peptide, and could be inhibited by a recombinant version of the mid-domain anti-Aβ antibody solanezumab.

  1. PET/CT with 18F-choline: Physiological whole bio-distribution in male and female subjects and diagnostic pitfalls on 1000 prostate cancer patients: 18F-choline PET/CT bio-distribution and pitfalls. A southern Italian experience.

    PubMed

    Calabria, Ferdinando; Chiaravalloti, Agostino; Cicciò, Carmelo; Gangemi, Vincenzo; Gullà, Domenico; Rocca, Federico; Gallo, Gianpasquale; Cascini, Giuseppe Lucio; Schillaci, Orazio

    2017-08-01

    The 11 C/ 18 F-choline is a PET/CT radiopharmaceutical useful in detecting tumors with high lipogenesis. 11 C/ 18 F-choline uptake can occur in physiological conditions or tumors. The knowledge of its bio-distribution is essential to recognize physiologic variants or diagnostic pitfalls. Moreover, few information are available on the bio-distribution of this tracer in female patients. Our aim was to discuss some documented 18 F-choline PET/CT pitfalls in prostate cancer patients. Our secondary aim was to describe the 18 F-choline bio-distribution in the female body. We collected diagnostic pitfalls in three PET centers examining 1000 prostate cancer by 18 F-choline PET/CT. All pitfalls were ensured by follow-up, imaging and/or histology. We also performed whole body 18 F-choline PET/CT in 5 female patients. 169/1000 (16.9%) patients showed pitfalls not owing to prostate cancer. These findings were due to inflammation, benign tumors while, in 1% of examined patients, a concomitant neoplasm was found. In the female body, the breast showed low physiological uptake. The accurate knowledge of 18 F-choline PET/CT bio-distribution and diagnostic pitfalls is essential. Correlative imaging and histological exam are often necessary to depict pitfalls. In women, the uptake in the breast is due to the physiological gradient of 18 F-choline uptake in the exocrine glands. Our results confirm the possibility of 18 F-choline uptake in several diseases other than prostate cancer. However, our experience was acquired on a large population and shows that a conspicuous amount of 18 F-choline diagnostic pitfalls are easily recognizable and attributable to inflammation. A new advance in knowledge is the minimal difference in terms of physiological tracer bio-distribution between male and female patients. The knowledge of the physiological bio-distribution and of the potential pitfalls linked of a tracer could help physicians to choose the best diagnostic and therapeutic approaches for a

  2. Multicenter Reproducibility of 18F-Fluciclatide PET Imaging in Subjects with Solid Tumors.

    PubMed

    Sharma, Rohini; Kallur, Kumar G; Ryu, Jin S; Parameswaran, Ramanathapuram V; Lindman, Henrik; Avril, Norbert; Gleeson, Fergus V; Lee, Jong D; Lee, Kyung-Han; O'Doherty, Michael J; Groves, Ashley M; Miller, Matthew P; Somer, Edward J; Coombes, Charles R; Aboagye, Eric O

    2015-12-01

    Integrins are upregulated on both tumor cells and associated vasculature, where they play an important role in angiogenesis and metastasis. Fluciclatide is an arginine-glycine-aspartic acid peptide with high affinity for αvβ3/αvβ5 integrin, which can be radiolabeled for PET imaging of angiogenesis. Thus, (18)F-fluciclatide is a potential biomarker of therapeutic response to antiangiogenic inhibitors. The aim of this study was to evaluate the reproducibility of (18)F-fluciclatide in multiple solid-tumor types. Thirty-nine patients underwent PET/CT scanning at 40, 65, and 90 min after injection of (18)F-fluciclatide (maximum, 370 MBq) on 2 separate days (2-9 d apart). Patients did not receive any therapy between PET/CT scans. (18)F-fluciclatide images were reported and quantitative measures of uptake were extracted using the PERCIST methodology. Intrasubject reproducibility of PET uptake in all measurable lesions was evaluated by calculating relative differences in SUV between PET scans for each lesion during the 2 imaging sessions. Thirty-nine measurable lesions were detected in 26 patients. Lesion uptake correlated strongly across imaging sessions (r = 0.92, P < 0.05, at 40 min; r = 0.94, P < 0.05, at 65 min; r = 0.94, P < 0.05, at 90 min) with a mean relative difference and SD of the relative difference of 0.006 ± 0.18 at 40 min, 0.003 ± 0.19 at 65 min, and 0.025 ± 0.20 at 90 min. This reflects 95% limits of repeatability of 35%-39% for the difference between the 2 SUV measurements or a variability of 18%-20% in agreement from that observed in well-calibrated multicenter (18)F-FDG studies. The test-retest reproducibility of (18)F-fluciclatide across multiple tumor types has been measured and shown to be acceptable. This is an important step in the development of this in vivo biomarker to identify and quantify response to antiangiogenic therapy in cancer patients. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  3. [(18)F]FDG PET Neuroimaging Predicts Pentylenetetrazole (PTZ) Kindling Outcome in Rats.

    PubMed

    Bascuñana, Pablo; Javela, Julián; Delgado, Mercedes; Fernández de la Rosa, Rubén; Shiha, Ahmed Anis; García-García, Luis; Pozo, Miguel Ángel

    2016-10-01

    Epileptogenesis, i.e., development of epilepsy, involves a number of processes that alter the brain function in the way that triggers spontaneous seizures. Kindling is one of the most used animal models of temporal lobe epilepsy (TLE) and epileptogenesis, although chemical kindling suffers from high inter-assay success unpredictability. This study was aimed to analyze the eventual regional brain metabolic changes during epileptogenesis in the pentylenetetrazole (PTZ) kindling model in order to obtain a predictive kindling outcome parameter. In vivo longitudinal positron emission tomography (PET) scans with 2-deoxy-2-[(18)F]fluoro-D-glucose ([(18)F]FDG) along the PTZ kindling protocol (35 mg/kg intraperitoneally (i.p.), 18 sessions) in adult male rats were performed in order to evaluate the regional brain metabolism. The half of the PTZ-injected rats reached the kindled state. In addition, a significant decrease of [(18)F]FDG uptake at the end of the protocol in most of the brain structures of kindled animals was found, reflecting the characteristic epilepsy-associated hypometabolism. However, PTZ-injected animals but not reaching the kindled state did not show this widespread brain hypometabolism. Retrospective analysis of the data revealed that hippocampal [(18)F]FDG uptake normalized to pons turned out to be a predictive index of the kindling outcome. Thus, a 19.06 % reduction (p = 0.008) of the above parameter was found in positively kindled rats compared to non-kindled ones just after the fifth PTZ session. Non-invasive PET neuroimaging was a useful tool for discerning epileptogenesis progression in this animal model. Particularly, the [(18)F]FDG uptake of the hippocampus proved to be an early predictive parameter to differentiate resistant and non-resistant animals to the PTZ kindling.

  4. Flight Tests of a Ministick Controller in an F/A-18 Airplane

    NASA Technical Reports Server (NTRS)

    Stoliker, Patrick C.; Carter, John

    2003-01-01

    In March of 1999, five pilots performed flight tests to evaluate the handling qualities of an F/A-18 research airplane equipped with a small-displacement center stick (ministick) controller that had been developed for the JAS 39 Gripen airplane (a fighter/attack/ reconnaissance airplane used by the Swedish air force). For these tests, the ministick was installed in the aft cockpit (see figure) and production support flight control computers (PSFCCs) were used as interfaces between the controller hardware and the standard F/A-18 flight-control laws. The primary objective of the flight tests was to assess any changes in handling qualities of the F/A-18 airplane attributable to the mechanical characteristics of the ministick. The secondary objective was to demonstrate the capability of the PSFCCs to support flight-test experiments.

  5. F-18 fluorodeoxyglucose: Its potential in differentiating between stress fracture and neoplasia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Paul, R.; Ahonen, A.; Virtama, P.

    1989-12-01

    F-18 fluorodeoxyglucose (FDG) accumulates into regions of enhanced glucose uptake and metabolism such as the brain, heart, and malignant tumors. The clinical usefulness of this positron-emitting radiopharmaceutical is illustrated in a case where the clinical picture and CT indicated a malignant bone lesion in the clavicle. Histologically a stress fracture was found secondary to chronic strain on the clavicle. On follow-up the lesion's course was benign. Planar imaging with F-18 FDG was performed twice during follow-up, and on both occasions there was no accumulation of radioactivity over the suspicious area, indicating normal glucose consumption. This case demonstrates the differential diagnosticmore » potential of F-18 FDG and shows that clinically useful information may be obtained without a position emission tomograph.« less

  6. Compartmental model of 18F-choline

    NASA Astrophysics Data System (ADS)

    Janzen, T.; Tavola, F.; Giussani, A.; Cantone, M. C.; Uusijärvi, H.; Mattsson, S.; Zankl, M.; Petoussi-Henß, N.; Hoeschen, C.

    2010-03-01

    The MADEIRA Project (Minimizing Activity and Dose with Enhanced Image quality by Radiopharmaceutical Administrations), aims to improve the efficacy and safety of 3D functional imaging by optimizing, among others, the knowledge of the temporal variation of the radiopharmaceuticals' uptake in and clearance from tumor and healthy tissues. With the help of compartmental modeling it is intended to optimize the time schedule for data collection and improve the evaluation of the organ doses to the patients. Administration of 18F-choline to screen for recurrence or the occurrence of metastases in prostate cancer patients is one of the diagnostic applications under consideration in the frame of the project. PET and CT images have been acquired up to four hours after injection of 18F-choline. Additionally blood and urine samples have been collected and measured in a gamma counter. The radioactivity concentration in different organs and data of plasma clearance and elimination into urine were used to set-up a compartmental model of the biokinetics of the radiopharmaceutical. It features a central compartment (blood) exchanging with organs. The structure describes explicitly liver, kidneys, spleen, plasma and bladder as separate units with a forcing function approach. The model is presented together with an evaluation of the individual and population kinetic parameters, and a revised time schedule for data collection is proposed. This optimized time schedule will be validated in a further set of patient studies.

  7. Biodistribution of amino-functionalized diamond nanoparticles. In vivo studies based on 18F radionuclide emission.

    PubMed

    Rojas, Santiago; Gispert, Juan D; Martín, Roberto; Abad, Sergio; Menchón, Cristina; Pareto, Deborah; Víctor, Víctor M; Alvaro, Mercedes; García, Hermenegildo; Herance, J Raúl

    2011-07-26

    Nanoparticles have been proposed for several biomedical applications; however, in vivo biodistribution studies to confirm their potential are scarce. Nanodiamonds are carbon nanoparticles that have been recently proposed as a promising biomaterial. In this study, we labeled nanodiamonds with (18)F to study their in vivo biodistribution by positron emission tomography. Moreover, the impact on the biodistribution of their kinetic particle size and of the surfactant agents has been evaluated. Radiolabeled diamond nanoparticles accumulated mainly in the lung, spleen, and liver and were excreted into the urinary tract. The addition of surfactant agents did not lead to significant changes in this pattern, with the exception of a slight reduction in the urinary excretion rate. On the other hand, after filtration of the radiolabeled diamond nanoparticles to remove those with a larger kinetic size, the uptake in the lung and spleen was completely inhibited and significantly reduced in the liver.

  8. Quantification of 18F-fluorocholine kinetics in patients with prostate cancer.

    PubMed

    Verwer, Eline E; Oprea-Lager, Daniela E; van den Eertwegh, Alfons J M; van Moorselaar, Reindert J A; Windhorst, Albert D; Schwarte, Lothar A; Hendrikse, N Harry; Schuit, Robert C; Hoekstra, Otto S; Lammertsma, Adriaan A; Boellaard, Ronald

    2015-03-01

    Choline kinase is upregulated in prostate cancer, resulting in increased (18)F-fluoromethylcholine uptake. This study used pharmacokinetic modeling to validate the use of simplified methods for quantification of (18)F-fluoromethylcholine uptake in a routine clinical setting. Forty-minute dynamic PET/CT scans were acquired after injection of 204 ± 9 MBq of (18)F-fluoromethylcholine, from 8 patients with histologically proven metastasized prostate cancer. Plasma input functions were obtained using continuous arterial blood-sampling as well as using image-derived methods. Manual arterial blood samples were used for calibration and correction for plasma-to-blood ratio and metabolites. Time-activity curves were derived from volumes of interest in all visually detectable lymph node metastases. (18)F-fluoromethylcholine kinetics were studied by nonlinear regression fitting of several single- and 2-tissue plasma input models to the time-activity curves. Model selection was based on the Akaike information criterion and measures of robustness. In addition, the performance of several simplified methods, such as standardized uptake value (SUV), was assessed. Best fits were obtained using an irreversible compartment model with blood volume parameter. Parent fractions were 0.12 ± 0.4 after 20 min, necessitating individual metabolite corrections. Correspondence between venous and arterial parent fractions was low as determined by the intraclass correlation coefficient (0.61). Results for image-derived input functions that were obtained from volumes of interest in blood-pool structures distant from tissues of high (18)F-fluoromethylcholine uptake yielded good correlation to those for the blood-sampling input functions (R(2) = 0.83). SUV showed poor correlation to parameters derived from full quantitative kinetic analysis (R(2) < 0.34). In contrast, lesion activity concentration normalized to the integral of the blood activity concentration over time (SUVAUC) showed good

  9. Investigation of cis-4-[18F]Fluoro-D-Proline Uptake in Human Brain Tumors After Multimodal Treatment.

    PubMed

    Verger, Antoine; Stoffels, Gabriele; Galldiks, Norbert; Lohmann, Philipp; Willuweit, Antje; Neumaier, Bernd; Geisler, Stefanie; Langen, Karl-Josef

    2018-04-23

    Cis-4-[ 18 F]fluoro-D-proline (D-cis-[ 18 F]FPro) has been shown to pass the intact blood-brain barrier and to accumulate in areas of secondary neurodegeneration and necrosis in the rat brain while uptake in experimental brain tumors is low. This pilot study explores the uptake behavior of D-cis-[ 18 F]FPro in human brain tumors after multimodal treatment. In a prospective study, 27 patients with suspected recurrent brain tumor after treatment with surgery, radiotherapy, and/or chemotherapy (SRC) were investigated by dynamic positron emission tomography (PET) using D-cis-[ 18 F]FPro (22 high-grade gliomas, one unspecified glioma, and 4 metastases). Furthermore, two patients with untreated lesions were included (one glioblastoma, one reactive astrogliosis). Data were compared with the results of PET using O-(2-[ 18 F]fluoroethyl)-L-tyrosine ([ 18 F]FET) which detects viable tumor tissue. Tracer distribution, mean and maximum lesion-to-brain ratios (LBR mean , LBR max ), and time-to-peak (TTP) of the time activity curve (TAC) of tracer uptake were evaluated. Final diagnosis was determined by histology (n = 9), clinical follow-up (n = 10), or by [ 18 F]FET PET (n = 10). D-cis-[ 18 F]FPro showed high uptake in both recurrent brain tumors (n = 11) and lesions classified as treatment-related changes (TRC) only (n = 16) (LBR mean 2.2 ± 0.7 and 2.1 ± 0.6, n.s.; LBR max 3.4 ± 1.2 and 3.2 ± 1.3, n.s.). The untreated glioblastoma and the lesion showing reactive astrogliosis exhibited low D-cis-[ 18 F]FPro uptake. Distribution of [ 18 F]FET and D-cis-[ 18 F]FPro uptake was discordant in 21/29 cases indicating that the uptake mechanisms are different. The high accumulation of D-cis-[ 18 F]FPro in pretreated brain tumors and TRC supports the hypothesis that tracer uptake is related to cell death. Further studies before and after therapy are needed to assess the potential of D-cis-[ 18 F]FPro for treatment monitoring.

  10. Flight-determined engine exhaust characteristics of an F404 engine in an F-18 airplane

    NASA Technical Reports Server (NTRS)

    Ennix, Kimberly A.; Burcham, Frank W., Jr.; Webb, Lannie D.

    1993-01-01

    The exhaust characteristics of the F-18 aircraft with an F404 engine are examined with reference to the results of an acoustic flight testing program. The discussion covers an overview of the flight test planning, instrumentation, test procedures, data analysis, engine modeling codes, and results. In addition, the paper presents the exhaust velocity and Mach number data for the climb-to-cruise, Aircraft Noise Prediction Program validation, and ground tests.

  11. Postinjection L-phenylalanine increases basal ganglia contrast in PET scans of 6-18F-DOPA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Doudet, D.J.; McLellan, C.A.; Aigner, T.G.

    The sensitivity of 18F-DOPA positron emission tomography for imaging presynaptic dopamine systems is limited by the amount of specific-to-nonspecific accumulation of radioactivity in brain. In rhesus monkeys, we have been able to increase this ratio by taking advantage of the lag time between 18F-DOPA injection and the formation of its main metabolite, the amino acid 18F-fluoromethoxydopa, the entrance of which into brain is responsible for most of the brain's nonspecific radioactivity. By infusing an unlabeled amino acid, L-phenylalanine, starting 15 min after 18F-DOPA administration, we preferentially blocked the accumulation of 18F-fluoromethoxydopa by preventing its entrance into brain through competition atmore » the large neutral amino acid transport system of the blood-brain barrier. This method appears as reliable as the original and more sensitive, as demonstrated by the comparison of normal and MPTP-treated animals under both conditions.« less

  12. [18F]Fluorocholine PET/CT Imaging of Liver Cancer: Radiopathologic Correlation with Tissue Phospholipid Profiling.

    PubMed

    Kwee, Sandi A; Sato, Miles M; Kuang, Yu; Franke, Adrian; Custer, Laurie; Miyazaki, Kyle; Wong, Linda L

    2017-06-01

    [ 18 F]fluorocholine PET/CT can detect hepatocellular carcinoma (HCC) based on imaging the initial steps of phosphatidylcholine synthesis. To relate the diagnostic performance of [ 18 F]fluorocholine positron emission tomography (PET)/x-ray computed tomography (CT) to the phospholipid composition of liver tumors, radiopathologic correspondence was performed in patients with early-stage liver cancer who had undergone [ 18 F]fluorocholine PET/CT before tumor resection. Tumor and adjacent liver were profiled by liquid chromatography mass spectrometry, quantifying phosphatidylcholine species by mass-to-charge ratio. For clinical-radiopathologic correlation, HCC profiles were reduced to two orthogonal principal component factors (PCF1 and PCF2) accounting for 80 % of total profile variation. Tissues from 31 HCC patients and 4 intrahepatic cholangiocarcinoma (ICC) patients were analyzed, revealing significantly higher levels of phosphocholine, CDP-choline, and highly saturated phosphatidylcholine species in HCC tumors relative to adjacent liver and ICC tumors. Significant loading values for PCF1 corresponded to phosphatidylcholines containing poly-unsaturated fatty acids while PCF2 corresponded only to highly saturated phosphatidylcholines. Only PCF2 correlated significantly with HCC tumor-to-liver [ 18 F]fluorocholine uptake ratio (ρ = 0.59, p < 0.0005). Sensitivity for all tumors based on an abnormal [ 18 F]fluorocholine uptake ratio was 93 % while sensitivity for HCC based on increased tumor [ 18 F]fluorocholine uptake was 84 %, with lower levels of highly saturated phosphatidylcholines in tumors showing low [ 18 F]fluorocholine uptake. Most HCC tumors contain high levels of saturated phosphatidylcholines, supporting their dependence on de novo fatty acid metabolism for phospholipid membrane synthesis. While [ 18 F]fluorocholine PET/CT can serve to identify these lipogenic tumors, its imperfect diagnostic sensitivity implies metabolic heterogeneity across HCC

  13. [18F]fluorocholine PET/CT imaging of liver cancer: radiopathologic correlation with tissue phospholipid profiling

    PubMed Central

    Kwee, Sandi A; Sato, Miles M; Kuang, Yu; Franke, Adrian; Custer, Laurie; Miyazaki, Kyle; Wong, Linda L

    2017-01-01

    BACKGROUND [18F]fluorocholine PET/CT can detect hepatocellular carcinoma (HCC) based on imaging the initial steps of phosphatidylcholine synthesis. To relate the diagnostic performance of [18F]fluorocholine PET/CT to the phospholipid composition of liver tumors, radiopathologic correspondence was performed in patients with early-stage liver cancer who had undergone [18F]fluorocholine PET/CT before tumor resection. METHODS Tumor and adjacent liver were profiled by liquid chromatography mass spectrometry, quantifying phosphatidylcholine species by mass-to-charge ratio. For clinical-radiopathologic correlation, HCC profiles were reduced to two orthogonal principal component factors (PCF1 and PCF2) accounting for 80% of total profile variation. RESULTS Tissues from 31 HCC patients and 4 intrahepatic cholangiocarcinoma (ICC) patients were analyzed, revealing significantly higher levels of phosphocholine, CDP-choline, and highly-saturated phosphatidylcholine species in HCC tumors relative to adjacent liver and ICC tumors. Significant loading values for PCF1 corresponded to phosphatidylcholines containing poly-unsaturated fatty acids while PCF2 corresponded only to highly-saturated phosphatidylcholines. Only PCF2 correlated significantly with HCC tumor-to-liver [18F]fluorocholine uptake ratio (ρ = 0.59, p < 0.0005). Sensitivity for all tumors based on an abnormal [18F]fluorocholine uptake ratio was 93%, while sensitivity for HCC based on increased tumor [18F]fluorocholine uptake was 84%, with lower levels of highly-saturated phosphatidylcholines in tumors showing low [18F]fluorocholine uptake. CONCLUSION Most HCC tumors contain high levels of saturated phosphatidylcholines, supporting their dependence on de-novo fatty acid metabolism for phospholipid membrane synthesis. While [18F]fluorocholine PET/CT can serve to identify these lipogenic tumors, its imperfect diagnostic sensitivity implies metabolic heterogeneity across HCC and a weaker lipogenic phenotype in some

  14. Status of development of LCOS projection displays for F-22A, F/A-18E/F, and JSF cockpits

    NASA Astrophysics Data System (ADS)

    Kalmanash, Michael H.

    2001-09-01

    Projection display technology has been found to be an attractive alternative to direct view flat panel displays in many avionics applications. The projection approach permits compact high performance systems to be tailored to specific platform needs while using a complement of commercial off the shelf (COTS) components, including liquid crystal on silicon (LCOS) microdisplay imagers. A common projection engine used on multiple platforms enables improved performance, lower cost and shorter development cycles. This paper provides a status update for projection displays under development for the F-22A, the F/A-18E/F and the Lockheed Joint Strike Fighter (JSF) aircraft.

  15. Development of Purine-Derived 18F-Labeled Pro-drug Tracers for Imaging of MRP1 Activity with PET

    PubMed Central

    2014-01-01

    Multidrug resistance-associated protein 1 (MRP1) is a drug efflux transporter that has been implicated in the pathology of several neurological diseases and is associated with development of multidrug resistance. To enable measurement of MRP1 function in the living brain, a series of 6-halopurines decorated with fluorinated side chains have been synthesized and evaluated as putative pro-drug tracers. The tracers were designed to undergo conjugation with glutathione within the brain and hence form the corresponding MRP1 substrate tracers in situ. 6-Bromo-7-(2-[18F]fluoroethyl)purine showed good brain uptake and rapid metabolic conversion. Dynamic PET imaging demonstrated a marked difference in brain clearance rates between wild-type and mrp1 knockout mice, suggesting that the tracer can allow noninvasive assessment of MRP1 activity in vivo. PMID:24456310

  16. Process for the production of 18F-2-deoxy-2-fluoro-D-glucose

    DOEpatents

    Shiue, Chyng-Yann; Salvadori, Piero A.; Wolf, Alfred P.; Fowler, Joanna S.; MacGregor, Robert R.

    1986-05-06

    Process for the production of 2-deoxy-2-fluoro-D-glucose and the corresponding .sup.18 F-compound by the reaction of acetyl hypofluorite or the corresponding .sup.18 F-compound with 3,4,6-tri-O-acetyl-D-glucal followed by hydrolysis. Process includes the production of the hypofluorite compound at ambient temperature.

  17. Process for the production of 18F-2-deoxy-2-fluoro-D-glucose

    DOEpatents

    Shiue, Chyng-Yann; Salvadori, Piero A.; Wolf, Alfred P.; Fowler, Joanna S.; MacGregor, Robert R.

    1986-01-01

    Process for the production of 2-deoxy-2-fluoro-D-glucose and the corresponding .sup.18 F-compound by the reaction of acetyl hypofluorite or the corresponding .sup.18 F-compound with 3,4,6-tri-O-acetyl-D-glucal followed by hydrolysis. Process includes the production of the hypofluorite compound at ambient temperature.

  18. Activity measurements of the radionuclides 18F and 64Cu for the NIST, USA in the ongoing comparisons BIPM.RI(II)-K4.F-18 and BIPM.RI(II)-K4.Cu-64

    NASA Astrophysics Data System (ADS)

    Michotte, C.; Nonis, M.; Bergeron, D.; Cessna, J.; Fitzgerald, R.; Pibida, L.; Zimmerman, B.; Fenwick, A.; Ferreira, K.; Keightley, J.; Da Silva, I.

    2017-01-01

    In 2016, comparisons of activity measurements of 18F and 64Cu using the Transfer Instrument of the International Reference System (SIRTI) took place at the National Institute of Standards and Technology (NIST, USA). This is the first SIRTI comparison for 64Cu. Ampoules containing about 27 kBq of 18F and 100 kBq of 64Cu solutions were measured in the SIRTI for about 5 and 1.5 half-lives, respectively. The NIST standardized the activity in the ampoules by ionization chamber measurements traceable to 4π(LS)β-γ anticoincidence measurements. The comparisons, identifiers BIPM.RI(II)-K4.F-18 and BIPM.RI(II)-K4.Cu-64, are linked to the corresponding BIPM.RI(II)-K1.F-18 and BIPM.RI(II)-K1.Cu-64 comparisons and degrees of equivalence with the respective key comparison reference values have been evaluated. The NIST replaces its earlier degree of equivalence for 18F obtained in the frame of the CCRI(II)-K3.F-18 comparison in 2001. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  19. Diagnosing neuroleukemiosis: Is there a role for 18F-FDG-PET/CT?

    PubMed

    Sabaté-Llobera, A; Cortés-Romera, M; Gamundí-Grimalt, E; Sánchez-Fernández, J J; Rodríguez-Bel, L; Gámez-Cenzano, C

    An imaging case is presented on a patient referred to our department for an 18 F-FDG-PET/CT, as a paraneoplastic syndrome was suspected due to his clinical situation. He had a history of acute myeloid leukemia (AML) treated two years earlier, with sustained complete remission to date. 18 F-FDG-PET/CT findings revealed hypermetabolism in almost all nerve roots, suggesting meningeal spread, consistent with the subsequent MRI findings. Cerebrospinal fluid (CSF) findings confirmed a leptomeningeal reactivation of AML. Although not many studies have evaluated the role of 18 F-FDG-PET/CT in leukemia, it is a noninvasive tool for detecting extramedullary sites of disease and a good imaging alternative for those patients on whom an MRI cannot be performed. Copyright © 2017 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  20. The effect of bi-terminal PEGylation of an integrin  α vβ 6-targeted 18F peptide on pharmacokinetics and tumor uptake

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hausner, Sven H.; Bauer, Nadine; Hu, Lina Y.

    Radiotracers based on the peptide A20FMDV2 selectively target the cell surface receptor integrin α vβ 6. This integrin has been identified as a prognostic indicator correlating with the severity of disease for several challenging malignancies. In previous studies of A20FMDV2 peptides labeled with 4- 18F-fluorobenzoic acid ( 18F-FBA), we have shown that the introduction of poly(ethylene glycol) (PEG) improves pharmacokinetics, including increased uptake in α vβ 6-expressing tumors. The present study evaluated the effect of site-specific C-terminal or dual (N- and C-terminal) PEGylation, yielding 18F-FBA-A20FMDV2-PEG 28 (4) and 18F-FBA-PEG 28-A20FMDV2-PEG 28 (5), on α vβ 6-targeted tumor uptake and pharmacokinetics.more » The results are compared with 18F-FBA–labeled A20FMDV2 radiotracers (1–3) bearing either no PEG or different PEG units at the N terminus. The radiotracers were prepared and radiolabeled on solid phase. Using 3 cell lines, DX3puroβ6 (α vβ 6+), DX3puro (α vβ 6–), and BxPC-3 (α vβ 6+), we evaluated the radiotracers in vitro (serum stability; cell binding and internalization) and in vivo in mouse models bearing paired DX3puroβ6–DX3puro and, for 5, BxPC-3 xenografts. Here, the size and location of the PEG units significantly affected α vβ 6 targeting and pharmacokinetics. Although the C-terminally PEGylated 4 showed some improvements over the un-PEGylated 18F-FBA-A20FMDV2 (1), it was the bi-terminally PEGylated 5 that displayed the more favorable combination of high α vβ 6 affinity, selectivity, and pharmacokinetic profile. In vitro, 5 bound to α vβ 6-expressing DX3puroβ6 and BxPC-3 cells with 60.5% ± 3.3% and 48.8% ± 8.3%, respectively, with a significant fraction of internalization (37.2% ± 4.0% and 37.6% ± 4.1% of total radioactivity, respectively). By comparison, in the DX3puro control 5 showed only 3.0% ± 0.5% binding and 0.9% ± 0.2% internalization. In vivo, 5 maintained high, α vβ 6-directed binding in the