Recent developments in measurement and evaluation of FAC damage in power plants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Garud, Y.S.; Besuner, P.; Cohn, M.J.
1999-11-01
This paper describes some recent developments in the measurement and evaluation of flow-accelerated corrosion (FAC) damage in power plants. The evaluation focuses on data checking and smoothing to account for gross errors, noise, and uncertainty in the wall thickness measurements from ultrasonic or pulsed eddy-current data. Also, the evaluation method utilizes advanced regression analysis for spatial and temporal evolution of the wall loss, providing statistically robust predictions of wear rates and associated uncertainty. Results of the application of these new tools are presented for several components in actual service. More importantly, the practical implications of using these advances are discussedmore » in relation to the likely impact on the scope and effectiveness of FAC related inspection programs.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vanderhoff, J. F.; Rao, G. V.; Stein, A.
2012-07-01
The issue of Flow Accelerated Erosion-Corrosion (FAC) in power plant piping is a known phenomenon that has resulted in material replacements and plant accidents in operating power plants. Therefore, it is important for FAC resistance to be considered in the design of new nuclear power plants. This paper describes the design considerations related to FAC that were used to develop a safe and robust AP1000{sup R} plant secondary side piping design. The primary FAC influencing factors include: - Fluid Temperature - Pipe Geometry/layout - Fluid Chemistry - Fluid Velocity - Pipe Material Composition - Moisture Content (in steam lines) Duemore » to the unknowns related to the relative impact of the influencing factors and the complexities of the interactions between these factors, it is difficult to accurately predict the expected wear rate in a given piping segment in a new plant. This paper provides: - a description of FAC and the factors that influence the FAC degradation rate, - an assessment of the level of FAC resistance of AP1000{sup R} secondary side system piping, - an explanation of options to increase FAC resistance and associated benefits/cost, - discussion of development of a tool for predicting FAC degradation rate in new nuclear power plants. (authors)« less
2 CFR 200.36 - Federal Audit Clearinghouse (FAC).
Code of Federal Regulations, 2014 CFR
2014-01-01
... 2 Grants and Agreements 1 2014-01-01 2014-01-01 false Federal Audit Clearinghouse (FAC). 200.36... Clearinghouse (FAC). FAC means the clearinghouse designated by OMB as the repository of record where non-Federal... part. The mailing address of the FAC is Federal Audit Clearinghouse, Bureau of the Census, 1201 E. 10th...
A green emissive amorphous fac-Alq3 solid generated by grinding crystalline blue fac-Alq3 powder.
Bi, Hai; Chen, Dong; Li, Di; Yuan, Yang; Xia, Dandan; Zhang, Zuolun; Zhang, Hongyu; Wang, Yue
2011-04-14
A novel green emissive Alq(3) solid with a facial isomeric form has been obtained by grinding the typical blue luminescent fac-Alq(3) crystalline powder. This is the first report, to the best of our knowledge, that a fac-Alq(3) isomer emits green light.
Properties and behaviour of FAC currents in the inner magnetosphere
NASA Astrophysics Data System (ADS)
Yang, Junying; Dunlop, Malcolm; Yang, Yanyan; Xiong, Chao; Lühr, Hermann; Cao, Jinbin; Li, Liuyuan; Ma, Yuduan; Shen, Chao
2017-04-01
Cusp, region 1 and 2, and other large scale field-aligned currents (FACs), are sampled in situ by both the four Cluster spacecraft and by the three Swarm spacecraft at different altitudes, separated by a few to several Earth radii, and sometimes simultaneously. Here, the capability of Swarm-Cluster coordination for probing the behaviour of the field aligned currents (FACs) at medium and low orbits is explored. Joint signatures of R1 and R2 FACs (as well as cusp, R0 and NBZ currents) can be found and compared in terms of the magnetic signatures, using multi-spacecraft analysis where possible. Using the Swarm configuration, statistical correlation analysis of the local time variation of R1/R2 FACs can be shown and compared to standard MVA analysis. For context, we identify the associated auroral boundaries through application of a method to determine the FAC intensity gradients in order to interpret and resolve the R1 and R2 FACs. We also explore the relation of R2 FACs to the ring current properties measured in situ.
A FPGA Implementation of the CAR-FAC Cochlear Model.
Xu, Ying; Thakur, Chetan S; Singh, Ram K; Hamilton, Tara Julia; Wang, Runchun M; van Schaik, André
2018-01-01
This paper presents a digital implementation of the Cascade of Asymmetric Resonators with Fast-Acting Compression (CAR-FAC) cochlear model. The CAR part simulates the basilar membrane's (BM) response to sound. The FAC part models the outer hair cell (OHC), the inner hair cell (IHC), and the medial olivocochlear efferent system functions. The FAC feeds back to the CAR by moving the poles and zeros of the CAR resonators automatically. We have implemented a 70-section, 44.1 kHz sampling rate CAR-FAC system on an Altera Cyclone V Field Programmable Gate Array (FPGA) with 18% ALM utilization by using time-multiplexing and pipeline parallelizing techniques and present measurement results here. The fully digital reconfigurable CAR-FAC system is stable, scalable, easy to use, and provides an excellent input stage to more complex machine hearing tasks such as sound localization, sound segregation, speech recognition, and so on.
A FPGA Implementation of the CAR-FAC Cochlear Model
Xu, Ying; Thakur, Chetan S.; Singh, Ram K.; Hamilton, Tara Julia; Wang, Runchun M.; van Schaik, André
2018-01-01
This paper presents a digital implementation of the Cascade of Asymmetric Resonators with Fast-Acting Compression (CAR-FAC) cochlear model. The CAR part simulates the basilar membrane's (BM) response to sound. The FAC part models the outer hair cell (OHC), the inner hair cell (IHC), and the medial olivocochlear efferent system functions. The FAC feeds back to the CAR by moving the poles and zeros of the CAR resonators automatically. We have implemented a 70-section, 44.1 kHz sampling rate CAR-FAC system on an Altera Cyclone V Field Programmable Gate Array (FPGA) with 18% ALM utilization by using time-multiplexing and pipeline parallelizing techniques and present measurement results here. The fully digital reconfigurable CAR-FAC system is stable, scalable, easy to use, and provides an excellent input stage to more complex machine hearing tasks such as sound localization, sound segregation, speech recognition, and so on. PMID:29692700
48 CFR 301.607-76 - FAC-P/PM application process.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false FAC-P/PM application... 301.607-76 FAC-P/PM application process. The P/PM Handbook contains application procedures and forms...; recertification; and certification waiver. Applicants for HHS FAC-P/PM certification actions shall comply with the...
48 CFR 301.607-76 - FAC-P/PM application process.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 4 2011-10-01 2011-10-01 false FAC-P/PM application... 301.607-76 FAC-P/PM application process. The P/PM Handbook contains application procedures and forms...; recertification; and certification waiver. Applicants for HHS FAC-P/PM certification actions shall comply with the...
48 CFR 301.607-76 - FAC-P/PM application process.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 48 Federal Acquisition Regulations System 4 2014-10-01 2014-10-01 false FAC-P/PM application... 301.607-76 FAC-P/PM application process. The P/PM Handbook contains application procedures and forms...; recertification; and certification waiver. Applicants for HHS FAC-P/PM certification actions shall comply with the...
48 CFR 301.607-76 - FAC-P/PM application process.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 4 2012-10-01 2012-10-01 false FAC-P/PM application... 301.607-76 FAC-P/PM application process. The P/PM Handbook contains application procedures and forms...; recertification; and certification waiver. Applicants for HHS FAC-P/PM certification actions shall comply with the...
48 CFR 301.607-76 - FAC-P/PM application process.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 48 Federal Acquisition Regulations System 4 2013-10-01 2013-10-01 false FAC-P/PM application... 301.607-76 FAC-P/PM application process. The P/PM Handbook contains application procedures and forms...; recertification; and certification waiver. Applicants for HHS FAC-P/PM certification actions shall comply with the...
Martí-Arbona, Ricardo; Teshima, Munehiro; Anderson, Penelope S; Nowak-Lovato, Kristy L; Hong-Geller, Elizabeth; Unkefer, Clifford J; Unkefer, Pat J
2012-01-01
We have developed a high-throughput approach using frontal affinity chromatography coupled to mass spectrometry (FAC-MS) for the identification and characterization of the small molecules that modulate transcriptional regulator (TR) binding to TR targets. We tested this approach using the methionine biosynthesis regulator (MetJ). We used effector mixtures containing S-adenosyl-L-methionine (SAM) and S-adenosyl derivatives as potential ligands for MetJ binding. The differences in the elution time of different compounds allowed us to rank the binding affinity of each compound. Consistent with previous results, FAC-MS showed that SAM binds to MetJ with the highest affinity. In addition, adenine and 5'-deoxy-5'-(methylthio)adenosine bind to the effector binding site on MetJ. Our experiments with MetJ demonstrate that FAC-MS is capable of screening complex mixtures of molecules and identifying high-affinity binders to TRs. In addition, FAC-MS experiments can be used to discriminate between specific and nonspecific binding of the effectors as well as to estimate the dissociation constant (K(d)) for effector-TR binding. Copyright © 2012 S. Karger AG, Basel.
48 CFR 301.603-72 - FAC-C and HHS SAC certification requirements.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 48 Federal Acquisition Regulations System 4 2013-10-01 2013-10-01 false FAC-C and HHS SAC... Responsibilities 301.603-72 FAC-C and HHS SAC certification requirements. (a) The FAC-C certification program is... thereunder are not required to re-take training courses, but shall follow FAC-C training requirements when...
48 CFR 301.603-72 - FAC-C and HHS SAC certification requirements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 48 Federal Acquisition Regulations System 4 2014-10-01 2014-10-01 false FAC-C and HHS SAC... Responsibilities 301.603-72 FAC-C and HHS SAC certification requirements. (a) The FAC-C certification program is... thereunder are not required to re-take training courses, but shall follow FAC-C training requirements when...
48 CFR 301.603-72 - FAC-C and HHS SAC certification requirements.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 4 2011-10-01 2011-10-01 false FAC-C and HHS SAC... Responsibilities 301.603-72 FAC-C and HHS SAC certification requirements. (a) The FAC-C certification program is... thereunder are not required to re-take training courses, but shall follow FAC-C training requirements when...
48 CFR 301.603-72 - FAC-C and HHS SAC certification requirements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 4 2012-10-01 2012-10-01 false FAC-C and HHS SAC... Responsibilities 301.603-72 FAC-C and HHS SAC certification requirements. (a) The FAC-C certification program is... thereunder are not required to re-take training courses, but shall follow FAC-C training requirements when...
Predicting, examining, and evaluating FAC in US power plants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cohn, M.J.; Garud, Y.S.; Raad, J. de
1999-11-01
There have been many pipe failures in fossil and nuclear power plant piping systems caused by flow-accelerated corrosion (FAC). In some piping systems, this failure mechanism maybe the most important type of damage to mitigate because FAC damage has led to catastrophic failures and fatalities. Detecting the damage and mitigating the problem can significantly reduce future forced outages and increase personnel safety. This article discusses the implementation of recent developments to select FAC inspection locations, perform cost-effective examinations, evaluate results, and mitigate FAC failures. These advances include implementing the combination of software to assist in selecting examination locations and anmore » improved pulsed eddy current technique to scan for wall thinning without removing insulation. The use of statistical evaluation methodology and possible mitigation strategies also are discussed.« less
Martín, Miguel; Ruiz, Amparo; Ruiz Borrego, Manuel; Barnadas, Agustí; González, Sonia; Calvo, Lourdes; Margelí Vila, Mireia; Antón, Antonio; Rodríguez-Lescure, Alvaro; Seguí-Palmer, Miguel Angel; Muñoz-Mateu, Montserrat; Dorca Ribugent, Joan; López-Vega, José Manuel; Jara, Carlos; Espinosa, Enrique; Mendiola Fernández, César; Andrés, Raquel; Ribelles, Nuria; Plazaola, Arrate; Sánchez-Rovira, Pedro; Salvador Bofill, Javier; Crespo, Carmen; Carabantes, Francisco J; Servitja, Sonia; Chacón, José Ignacio; Rodríguez, César A; Hernando, Blanca; Álvarez, Isabel; Carrasco, Eva; Lluch, Ana
2013-07-10
Adding taxanes to anthracycline-based adjuvant therapy improves survival outcomes of patients with node-positive breast cancer (BC). Currently, however, most patients with BC are node negative at diagnosis. The only pure node-negative study (Spanish Breast Cancer Research Group 9805) reported so far showed a docetaxel benefit but significant toxicity. Here we tested the efficacy and safety of weekly paclitaxel (wP) in node-negative patients, which is yet to be established. Patients with BC having T1-T3/N0 tumors and at least one high-risk factor for recurrence (according to St. Gallen 1998 criteria) were eligible. After primary surgery, 1,925 patients were randomly assigned to receive fluorouracil, doxorubicin, and cyclophosphamide (FAC) × 6 or FAC × 4 followed by wP × 8 (FAC-wP). The primary end point was disease-free survival (DFS) after a median follow-up of 5 years. Secondary end points included toxicity and overall survival. After a median follow-up of 63.3 months, 93% and 90.3% of patients receiving FAC-wP or FAC regimens, respectively, remained disease free (hazard ratio [HR], 0.73; 95% CI, 0.54 to 0.99; log-rank P = .04). Thirty-one patients receiving FAC-wP versus 40 patients receiving FAC died (one and seven from cardiovascular diseases, respectively; HR, 0.79; 95% CI, 0.49 to 1.26; log-rank P = .31). The most relevant grade 3 and 4 adverse events in the FAC-wP versus the FAC arm were febrile neutropenia (2.7% v 3.6%), fatigue (7.9% v 3.4%), and sensory neuropathy (5.5% v 0%). For patients with high-risk node-negative BC, the adjuvant FAC-wP regimen was associated with a small but significant improvement in DFS compared with FAC therapy, in addition to manageable toxicity, especially regarding long-term cardiac effects.
NASA Astrophysics Data System (ADS)
Nakamizo, A.; Yoshikawa, A.
2016-12-01
Whereas it is generally thought that Birkeland Currents (FACs) are generated in the magnetosphere and that the ionospheric convection reflects the magnetospheric convection, we present a possibility that the ionosphere drives FACs and the convection field in the M-I system. We apply this idea to the Harang Reversal (HR) for demonstration. By using an ionospheric potential solver we calculate the electrostatic field for given distributions of FACs and conductance. The result shows that a conspicuous structure resembling HR is generated even for a symmetric distribution of the R1-type FACs and that the Hall polarization field is produced at the equatorward boundary of the auroral region as the primary currents diverge/converge at the conductance gradient there, which causes the potential deformation (HR). Conventionally HR has been considered to be of the magnetospheric origin, and a ring current model actually produces the corresponding structure in the magnetosphere [e.g., Erickson et al., 1991]. Observationally the divE equivalent to HR is consistent with the premidnight upward-FAC seen in Iijima and Potemra's diagram. A recent theoretical study [Ohtani et al., 2016] proposes that HR is a required structure for the interchange stability of the magnetotail in the presence of the R1 and R2-FAC systems including a premidnight upward-FAC. Returning to our result, the important point is that HR is reproduced at the conductance edge by the ionospheric polarization field, for which the primary field originates from the R1-FACs distributed far from that region. We also suggest: (i) In a more realistic finite ΣA, the total ionospheric polarization is partly released by a FAC, which may be a part of the premidnight upward-FAC. (ii) However, existing simulation models do not allow this type of current closure, and accordingly they may enhance the HR structure in the magnetosphere. This discussion should hold generally and would promote the global M-I coupling studies to the
Identification of the First Diketomorpholine Biosynthetic Pathway Using FAC-MS Technology.
Robey, Matthew T; Ye, Rosa; Bok, Jin Woo; Clevenger, Kenneth D; Islam, Md Nurul; Chen, Cynthia; Gupta, Raveena; Swyers, Michael; Wu, Edward; Gao, Peng; Thomas, Paul M; Wu, Chengcang C; Keller, Nancy P; Kelleher, Neil L
2018-05-18
Filamentous fungi are prolific producers of secondary metabolites with drug-like properties, and their genome sequences have revealed an untapped wealth of potential therapeutic leads. To better access these secondary metabolites and characterize their biosynthetic gene clusters, we applied a new platform for screening and heterologous expression of intact gene clusters that uses fungal artificial chromosomes and metabolomic scoring (FAC-MS). We leverage FAC-MS technology to identify the biosynthetic machinery responsible for production of acu-dioxomorpholine, a metabolite produced by the fungus, Aspergilllus aculeatus. The acu-dioxomorpholine nonribosomal peptide synthetase features a new type of condensation domain (designated C R ) proposed to use a noncanonical arginine active site for ester bond formation. Using stable isotope labeling and MS, we determine that a phenyllactate monomer deriving from phenylalanine is incorporated into the diketomorpholine scaffold. Acu-dioxomorpholine is highly related to orphan inhibitors of P-glycoprotein targets in multidrug-resistant cancers, and identification of the biosynthetic pathway for this compound class enables genome mining for additional derivatives.
NASA Astrophysics Data System (ADS)
Gu, Ming Feng
2018-02-01
FAC calculates various atomic radiative and collisional processes, including radiative transition rates, collisional excitation and ionization by electron impact, energy levels, photoionization, and autoionization, and their inverse processes radiative recombination and dielectronic capture. The package also includes a collisional radiative model to construct synthetic spectra for plasmas under different physical conditions.
Functional Activity of the Fanconi Anemia Protein FAA Requires FAC Binding and Nuclear Localization
Näf, Dieter; Kupfer, Gary M.; Suliman, Ahmed; Lambert, Kathleen; D’Andrea, Alan D.
1998-01-01
Fanconi anemia (FA) is an autosomal recessive disease characterized by genomic instability, cancer susceptibility, and cellular hypersensitivity to DNA-cross-linking agents. Eight complementation groups of FA (FA-A through FA-H) have been identified. Two FA genes, corresponding to complementation groups FA-A and FA-C, have been cloned, but the functions of the encoded FAA and FAC proteins remain unknown. We have recently demonstrated that FAA and FAC interact to form a nuclear complex. In this study, we have analyzed a series of mutant forms of the FAA protein with respect to functional activity, FAC binding, and nuclear localization. Mutation or deletion of the amino-terminal nuclear localization signal (NLS) of FAA results in loss of functional activity, loss of FAC binding, and cytoplasmic retention of FAA. Replacement of the NLS sequence with a heterologous NLS sequence, derived from the simian virus 40 T antigen, results in nuclear localization but does not rescue functional activity or FAC binding. Nuclear localization of the FAA protein is therefore necessary but not sufficient for FAA function. Mutant forms of FAA which fail to bind to FAC also fail to promote the nuclear accumulation of FAC. In addition, wild-type FAC promotes the accumulation of wild-type FAA in the nucleus. Our results suggest that FAA and FAC perform a concerted function in the cell nucleus, required for the maintenance of chromosomal stability. PMID:9742112
Klenc, Jeffrey; Lipowska, Malgorzata; Abhayawardhana, Pramuditha L; Taylor, Andrew T; Marzilli, Luigi G
2015-07-06
We previously identified two new agents based on the [(99m)Tc(V)O](3+) core with renal clearances in human volunteers 30% higher than that of the widely used clinical tracer (99m)Tc-MAG3 (MAG3(5-) = penta-anion of mercaptoacetyltriglycine). However, renal agents with even higher clearances are needed. More recently, we changed our focus from the [(99m)Tc(V)O](3+) core to the discovery of superior tracers based on the fac-[(99m)Tc(I)(CO)3](+) core. Compared to (99m)Tc-MAG3, fac-[(99m)Tc(I)(CO)3(NTA)](2-) (NTA(3-) = trianion of nitrilotriacetic acid) holds great promise by virtue of its efficient renal clearance via tubular secretion and the absence of hepatobiliary elimination, even in patients with severely reduced renal function. We report here NMR, molecular (X-ray) structure, and solution data on fac-[Re(I)(CO)3(NTA)](2-) with a -CH2CO2(-) dangling monoanionic chain and on two fac-[Re(I)(CO)3(L)](-) analogues with either a -CH2CONH2 or a -CH2CH2OH dangling neutral chain. In these three fac-[Re(I)(CO)3(L)](n-) complexes, the fac-[Re(I)(CO)3(N(CH2CO2)2)](-) moiety is structurally similar and has similar electronic properties (as assessed by NMR data). In reported and ongoing studies, the two fac-[(99m)Tc(I)(CO)3(L)](-) analogues with these neutral dangling chains were found to have pharmacokinetic properties very similar to those of fac-[(99m)Tc(I)(CO)3(NTA)](2-). Therefore, we reach the unexpected conclusion that in fac-[(99m)Tc(I)(CO)3(L)](n-) agents, renal clearance is affected much more than anticipated by features of the core plus the chelate rings (the [(99m)Tc(I)(CO)3(N(CH2CO2)2)](-) moiety) than by the presence of a negatively charged dangling carboxylate chain.
The Fanconi anemia pathway requires FAA phosphorylation and FAA/FAC nuclear accumulation
Yamashita, Takayuki; Kupfer, Gary M.; Naf, Dieter; Suliman, Ahmed; Joenje, Hans; Asano, Shigetaka; D’Andrea, Alan D.
1998-01-01
Fanconi anemia (FA) is an autosomal recessive cancer susceptibility syndrome with at least eight complementation groups (A–H). Two FA genes, corresponding to complementation groups A and C, have been cloned, but the function of the FAA and FAC proteins remains unknown. We have recently shown that the FAA and FAC proteins bind and form a nuclear complex. In the current study, we analyzed the FAA and FAC proteins in normal lymphoblasts and lymphoblasts from multiple FA complementation groups. In contrast to normal controls, FA cells derived from groups A, B, C, E, F, G, and H were defective in the formation of the FAA/FAC protein complex, the phosphorylation of the FAA protein, and the accumulation of the FAA/FAC protein complex in the nucleus. These biochemical events seem to define a signaling pathway required for the maintenance of genomic stability and normal hematopoiesis. Our results support the idea that multiple gene products cooperate in the FA Pathway. PMID:9789045
Individualized FAC on bottom tab subassemblies to minimize adhesive gap between emitter and optics
NASA Astrophysics Data System (ADS)
Sauer, Sebastian; Müller, Tobias; Haag, Sebastian; Beleke, Andreas; Zontar, Daniel; Baum, Christoph; Brecher, Christian
2017-02-01
High Power Diode Laser (HPDL) systems with short focal length fast-axis collimators (FAC) require submicron assembly precision. Conventional FAC-Lens assembly processes require adhesive gaps of 50 microns or more in order to compensate for component tolerances (e.g. deviation of back focal length) and previous assembly steps. In order to control volumetric shrinkage of fast-curing UV-adhesives shrinkage compensation is mandatory. The novel approach described in this paper aims to minimize the impact of volumetric shrinkage due to the adhesive gap between HPDL edge emitters and FAC-Lens. Firstly, the FAC is actively aligned to the edge emitter without adhesives or bottom tab. The relative position and orientation of FAC to emitter are measured and stored. Consecutively, an individual subassembly of FAC and bottom tab is assembled on Fraunhofer IPT's mounting station with a precision of +/-1 micron. Translational and lateral offsets can be compensated, so that a narrow and uniform glue gap for the consecutive bonding process of bottom tab to heatsink applies (Figure 4). Accordingly, FAC and bottom tab are mounted to the heatsink without major shrinkage compensation. Fraunhofer IPT's department assembly of optical systems and automation has made several publications regarding active alignment of FAC lenses [SPIE LASE 8241-12], volumetric shrinkage compensation [SPIE LASE 9730-28] and FAC on bottom tab assembly [SPIE LASE 9727-31] in automated production environments. The approach described in this paper combines these and is the logical continuation of that work towards higher quality of HPDLs.
Microfluidics microFACS for Life Detection
NASA Technical Reports Server (NTRS)
Platt, Donald W.; Hoover, Richard B.
2010-01-01
A prototype micro-scale Fluorescent Activated Cell Sorter (microFACS) for life detection has been built and is undergoing testing. A functional miniature microfluidics instrument with the ability to remotely distinguish live or dead bacterial cells from abiotic particulates in ice or permafrost of icy bodies of the solar system would be of fundamental value to NASA. The use of molecular probes to obtain the bio-signature of living or dead cells could answer the most fundamental question of Astrobiology: Does life exist beyond Earth? The live-dead fluorescent stains to be used in the microFACS instrument function only with biological cell walls. The detection of the cell membranes of living or dead bacteria (unlike PAH's and many other Biomarkers) would provide convincing evidence of present or past life. This miniature device rapidly examine large numbers of particulates from a polar ice or permafrost sample and distinguish living from dead bacteria cells and biological cells from mineral grains and abiotic particulates and sort the cells and particulates based on a staining system. Any sample found to exhibit fluorescence consistent with living cells could then be used in conjunction with a chiral labeled release experiment or video microscopy system to seek addition evidence for cellular metabolism or motility. Results of preliminary testing and calibration of the microFACS prototype instrument system with pure cultures and enrichment assemblages of microbial extremophiles will be reported.
Casanova, Massimo; Zangrando, Ennio; Munini, Fabio; Iengo, Elisabetta; Alessio, Enzo
2006-11-14
We show here that the new complex fac-[Re(CO)3(dmso-O)3](CF3SO3) (1), efficiently prepared in one step from [ReBr(CO)5] and featuring a broad range of solubility, is, in general, a better precursor for the one-step synthesis of mono- and polynuclear inorganic compounds containing fac-[Re(CO)3]+ fragments compared to the commonly used (NEt4)2fac-[ReBr3(CO)3] and fac-[Re(CO)3(CH3CN)3](Y) (Y = PF6, BF4, ClO4) species. Compound 1 is the first example of a Re(I)-dmso complex structurally characterized and confirms the rule that dmso is always O-bonded when trans to CO. The reactivity of 1 was tested in the one-step preparation of several new and known complexes. The O-bonded sulfoxides of 1 are replaced under mild conditions by tri- (L3) and bidentate ligands (L2) to produce fac-[Re(CO)3(L3)]+ and fac-[Re(CO)3(L2)(dmso-O)]+ compounds, respectively. An excess of monodentate ligands (L) and more forcing conditions are needed to prepare fac-[Re(CO)3(L)3]+ compounds. The new compounds include fac-[Re(CO)3(bipy)(dmso-O)](CF3SO3) (4), that turned out to be an excellent precursor for binding the luminescent fac-[Re(CO)3(bipy)]+ fragment to polytopic ligands for the construction of more elaborate assemblies. One example reported here is the two-step preparation of fac-[{Re(CO)3(bipy)}(mu-4,4'-bipy){Ru(TPP)(CO)}](CF3SO3) (8) (TPP = tetraphenylporphyrin). The X-ray structures of the new compounds 1, 4, of the bis-porphyrin complex fac-[Re(CO)3Cl(4'MPyP)2] (13) (4'MPyP = 5-(4'pyridyl)-10,15,20-triphenylporphyrin), and of the rhenium-cyclophane [{(CO)3Re(mu-OH)2Re(CO)3}2(micro-4,4'-bipy)2] (15), among others, are described. Compound 1 might find useful applications in supramolecular chemistry (metal-mediated assembly of large architectures), in the in situ preparation of stable Re compounds to be used in nuclear medicine, and for the labeling of biomolecules.
Coordinated aqua vs methanol substitution kinetics in fac-Re(I) tricarbonyl tropolonato complexes.
Schutte, Marietjie; Roodt, Andreas; Visser, Hendrik G
2012-11-05
Water-soluble fac-[Re(CO)(3)(L,L'-Bid)(X)] (L,L'-Bid = tropolonato, X = H(2)O, methanol) complexes have been synthesized, and the aqua and methanol substitution reactions were investigated in water (pH range 6.3-10.0) and methanol, respectively, and compared. Thiocyanate ions were used as monodentate entering ligand. The complexes were characterized by UV-vis, IR, and NMR spectroscopy. The crystal structures of the complexes [NEt(4)] fac-[Re(Trop)(CO)(3)(H(2)O)].NO(3).H(2)O (reactant) and fac-[Re(CO)(3)(Trop)(Py)], a substitution product, are reported. Overall it was found that the aqua substitution of fac-[Re(CO)(3)(Trop)(H(2)O)] is about 10 times faster than the methanol substitution reaction for fac-[Re(CO)(3)(Trop)(MeOH)], with forward and reverse rate and stability constants [k(1) (M(-1) s(-1)), k(-1) (s(-1)), K(1), (M(-1))] for thiocyanate as monodentate entering ligand as follows: fac-[Re(CO)(3)(Trop)(H(2)O)] = 2.54 ± 0.03, 0.0077 ± 0.0005, 330 ± 22/207 ± 14 and fac-[Re(CO)(3)(Trop)(MeOH)] = 0.268 ± 0.002, 0.0044 ± 0.0002, (61 ± 3)/(52 ± 4). The activation parameters [ΔH(‡)(k1) (kJ mol(-1)), ΔS(‡)(k1) (J K(-1) mol(-1))] for the aqua and methanol complex respectively are 56.1 ± 0.7, -49 ± 2 and 64 ± 1, -43 ± 5.
Albert, Jeffrey M; Buzdar, Aman U; Guzman, Reina; Allen, Pamela K; Strom, Eric A; Perkins, George H; Woodward, Wendy A; Hoffman, Karen E; Tereffe, Welela; Hunt, Kelly K; Buchholz, Thomas A; Oh, Julia L
2011-07-01
A previous randomized trial (CALGB 9344/Intergroup 0148) compared four cycles of adjuvant doxorubicin/cyclophosphamide (AC) to four cycles of AC plus four cycles of paclitaxel (AC + T) and demonstrated that the addition of paclitaxel improved locoregional control (LRC) in patients with node-positive breast cancer. However, it could not be determined whether it was the paclitaxel or the increased duration of chemotherapy that led to this improvement. The present study aimed to analyze whether the addition of paclitaxel to a doxorubicin-based regimen improves LRC in a cohort of patients who all received eight total cycles of chemotherapy. Five hundred eleven women with operable breast cancer were randomized on a single-institution prospective trial to receive 5-fluorouracil, doxorubicin, cyclophosphamide (FAC) × 8 cycles (n = 252) or FAC × 4 cycles plus paclitaxel × 4 cycles (TFAC) (n = 259). Rates of LRC and overall survival (OS) were analyzed. Median follow-up was 124 months (range 5-167 months). The 10-year LRC rate was 92.6 versus 93.1% in the FAC versus TFAC arms, respectively (P = 0.26). The LRC between treatment arms did not differ when analyzed by locoregional treatment group: breast conservation therapy (BCT), mastectomy alone (M), and mastectomy + radiation (M + RT). The 10-year LRC rates were 95.1% (FAC) versus 91.2% (TFAC) after BCT (P = 0.98), 89.5% (FAC) versus 93.4% (TFAC) after M (P = 0.24), and 94.7% (FAC) versus 96.5% (TFAC) after M + RT (P = 0.59). Additionally, there was no difference in OS between the treatment arms, with 10-year OS rates of 78.4% (FAC) versus 81.7% (TFAC) (P = 0.93). The addition of paclitaxel to a doxorubicin-based regimen had no impact on LRC, regardless of the type of local therapy received. Historically inferior LRC with AC chemotherapy alone versus AC + T may have been due to an inadequate duration of systemic therapy and not due to the absence of paclitaxel.
48 CFR 301.603-74 - Requirement for retention of FAC-C and HHS SAC certification.
Code of Federal Regulations, 2014 CFR
2014-10-01
... of FAC-C and HHS SAC certification. 301.603-74 Section 301.603-74 Federal Acquisition Regulations..., Contracting Authority, and Responsibilities 301.603-74 Requirement for retention of FAC-C and HHS SAC certification. To maintain FAC-C certification, all warranted Contracting Officers, regardless of series, as...
48 CFR 301.603-74 - Requirement for retention of FAC-C and HHS SAC certification.
Code of Federal Regulations, 2013 CFR
2013-10-01
... of FAC-C and HHS SAC certification. 301.603-74 Section 301.603-74 Federal Acquisition Regulations..., Contracting Authority, and Responsibilities 301.603-74 Requirement for retention of FAC-C and HHS SAC certification. To maintain FAC-C certification, all warranted Contracting Officers, regardless of series, as...
48 CFR 301.603-74 - Requirement for retention of FAC-C and HHS SAC certification.
Code of Federal Regulations, 2012 CFR
2012-10-01
... of FAC-C and HHS SAC certification. 301.603-74 Section 301.603-74 Federal Acquisition Regulations..., Contracting Authority, and Responsibilities 301.603-74 Requirement for retention of FAC-C and HHS SAC certification. To maintain FAC-C certification, all warranted Contracting Officers, regardless of series, as...
48 CFR 301.603-74 - Requirement for retention of FAC-C and HHS SAC certification.
Code of Federal Regulations, 2011 CFR
2011-10-01
... of FAC-C and HHS SAC certification. 301.603-74 Section 301.603-74 Federal Acquisition Regulations..., Contracting Authority, and Responsibilities 301.603-74 Requirement for retention of FAC-C and HHS SAC certification. To maintain FAC-C certification, all warranted Contracting Officers, regardless of series, as...
48 CFR 301.603-72 - FAC-C and HHS SAC certification requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... HUMAN SERVICES GENERAL HHS ACQUISITION REGULATION SYSTEM Career Development, Contracting Authority, and... retention of certification, including the requirement to earn continuous learning points (CLPs). FAC-C... to employees for the first time at a department or agency.) (c) The FAC-C certification is based on...
Zheng, Yonghao; Batsanov, Andrei S; Edkins, Robert M; Beeby, Andrew; Bryce, Martin R
2012-01-02
The new homoleptic tris-cyclometalated [Ir(C^N)(3)] complexes mer-8, fac-8, and fac-9 incorporating γ-carboline ligands are reported. Reaction of 3-(2,4-difluorophenyl)-5-(2-ethylhexyl)-pyrido[4,3-b]indole 6 with iridium(III) chloride under standard cyclometalating conditions gave the homoleptic complex mer-8 in 63% yield. The X-ray crystal structure of mer-8 is described. The Ir-C and Ir-N bonds show the expected bond length alternations for the differing trans influence of phenyl and pyridyl ligands. mer-8 quantitatively isomerized to fac-8 upon irradiation with UV light. However, heating mer-8 at 290 °C in glycerol led to an unusual regioselective loss of one fluorine atom from each of the ligands, yielding fac-9 in 58% yield. fac-8 is thermally very stable: no decomposition was observed when fac-8 was heated in glycerol at 290 °C for 48 h. The γ-carboline system of fac-8 enhances thermal stability compared to the pyridyl analogue fac-Ir(46dfppy)(3)10, which decomposes extensively upon being heated in glycerol at 290 °C for 2 h. Complexes mer-8, fac-8, and fac-9 are emitters of blue-green light (λ(max)(em) = 477, 476, and 494 nm, respectively). The triplet lifetimes for fac-8 and fac-9 are ~4.5 μs at room temperature; solution Φ(PL) values are 0.31 and 0.22, respectively.
Klenc, Jeffrey; Lipowska, Malgorzata; Taylor, Andrew T; Marzilli, Luigi G
2012-09-01
The reaction of an aminopolycarboxylate ligand, as partic- N - m onoacetic a cid (ASMA), with [Re(CO) 3 (H 2 O) 3 ] + was examined. The tridentate coordination of ASMA to this Re I tricarbonyl precursor yielded fac -Re(CO) 3 (ASMA) as a mixture of diastereomers. The chemistry is analogous to that of the Tc I tricarbonyl complex, which yields fac - 99m Tc(CO) 3 (ASMA) under similar conditions. The formation, structure, and isomerization of fac -Re(CO) 3 (ASMA) products were characterized by HPLC, 1 H NMR spectroscopy, and X-ray crystallography. The two major fac -Re(CO) 3 (ASMA) diastereomeric products each have a linear ONO coordination mode with two adjacent five-membered chelate rings, but they differ in the endo or exo orientation of the uncoordinated acetate group, in agreement with expectations based on previous studies. Conditions have been identified for the expedient isomerization of fac -Re(CO) 3 (ASMA) to a mixture consisting primarily of one major product. Because different isomeric species typically have different pharmacokinetic characteristics, these conditions may provide for the practical isolation of a single 99m Tc(CO) 3 (ASMA) species, thus allowing the isolation of the isomer that has optimal imaging and pharmacokinetic characteristics. This information will aid in the design of future 99m Tc radiopharmaceuticals.
Klenc, Jeffrey; Lipowska, Malgorzata; Taylor, Andrew T.; Marzilli, Luigi G.
2013-01-01
The reaction of an aminopolycarboxylate ligand, aspartic-N-monoacetic acid (ASMA), with [Re(CO)3(H2O)3]+ was examined. The tridentate coordination of ASMA to this ReI tricarbonyl precursor yielded fac-Re(CO)3(ASMA) as a mixture of diastereomers. The chemistry is analogous to that of the TcI tricarbonyl complex, which yields fac-99mTc(CO)3(ASMA) under similar conditions. The formation, structure, and isomerization of fac-Re(CO)3(ASMA) products were characterized by HPLC, 1H NMR spectroscopy, and X-ray crystallography. The two major fac-Re(CO)3(ASMA) diastereomeric products each have a linear ONO coordination mode with two adjacent five-membered chelate rings, but they differ in the endo or exo orientation of the uncoordinated acetate group, in agreement with expectations based on previous studies. Conditions have been identified for the expedient isomerization of fac-Re(CO)3(ASMA) to a mixture consisting primarily of one major product. Because different isomeric species typically have different pharmacokinetic characteristics, these conditions may provide for the practical isolation of a single 99mTc(CO)3(ASMA) species, thus allowing the isolation of the isomer that has optimal imaging and pharmacokinetic characteristics. This information will aid in the design of future 99mTc radiopharmaceuticals. PMID:24273448
NASA Astrophysics Data System (ADS)
Prabhu, T. Ram
2016-08-01
A wear model is developed based on the discrete lattice spring-mass approach to study the effects of particle volume fraction, size, and stiffness on the wear resistance of particle reinforced composites. To study these effects, we have considered three volume fractions (10%, 20% and 30%), two sizes (10 × 10 and 4 × 4 sites), and two different stiffness of particles embedded in the matrix in a regular pattern. In this model, we have discretized the composite system (400 × 100 sites) into the lumped masses connected with interaction spring elements in two dimensions. The interaction elements are assumed as linear elastic and ideal plastic under applied forces. Each mass is connected to its first and second nearest neighbors by springs. The matrix and particles sites are differentiated by choosing the different stiffness values. The counter surface is simulated as a rigid body that moves on the composite material at a constant sliding speed along the horizontal direction. The governing equations are formed by equating the spring force between the pair of sites given by Hooke’s law plus external contact forces and the force due to the motion of the site given by the equation of motion. The equations are solved for the plastic strain accumulated in the springs using an explicit time stepping procedure based on a finite difference form of the above equations. If the total strain accumulated in the spring elements connected to a lump mass site exceeds the failure strain, the springs are considered to be broken, and the mass site is removed or worn away from the lattice and accounts as a wear loss. The model predicts that (i) increasing volume fraction, reducing particle size and increasing particle stiffness enhance the wear resistance of the particle reinforced composites, (ii) the particle stiffness is the most significant factor affecting the wear resistance of the composites, and (iii) the wear resistance reduced above the critical volume fraction (Vc), and Vc
Kim, Siyeon; Lee, Joo-Young
2016-04-01
The aim of this study was to investigate stable and valid measurement sites of skin temperatures as a non-invasive variable to predict deep-body temperature while wearing firefighters' personal protective equipment (PPE) during air temperature changes. Eight male firefighters participated in an experiment which consisted of 60-min exercise and 10-min recovery while wearing PPE without self-contained breathing apparatus (7.75 kg in total PPE mass). Air temperature was periodically fluctuated from 29.5 to 35.5 °C with an amplitude of 6 °C. Rectal temperature was chosen as a deep-body temperature, and 12 skin temperatures were recorded. The results showed that the forehead and chest were identified as the most valid sites to predict rectal temperature (R(2) = 0.826 and 0.824, respectively) in an environment with periodically fluctuated air temperatures. This study suggests that particular skin temperatures are valid as a non-invasive variable when predicting rectal temperature of an individual wearing PPE in changing ambient temperatures. Practitioner Summary: This study should offer assistance for developing a more reliable indirect indicating system of individual heat strain for firefighters in real time, which can be used practically as a precaution of firefighters' heat-related illness and utilised along with physiological monitoring.
Metherell, Alexander J; Cullen, William; Stephenson, Andrew; Hunter, Christopher A; Ward, Michael D
2014-01-07
We have prepared a series of mononuclear fac and mer isomers of Ru(II) complexes containing chelating pyrazolyl-pyridine ligands, to examine their differing ability to act as hydrogen-bond donors in MeCN. This was prompted by our earlier observation that octanuclear cube-like coordination cages that contain these types of metal vertex can bind guests such as isoquinoline-N-oxide (K = 2100 M(-1) in MeCN), with a significant contribution to binding being a hydrogen-bonding interaction between the electron-rich atom of the guest and a hydrogen-bond donor site on the internal surface of the cage formed by a convergent set of CH2 protons close to a 2+ metal centre. Starting with [Ru(L(H))3](2+) [L(H) = 3-(2-pyridyl)-1H-pyrazole] the geometric isomers were separated by virtue of the fact that the fac isomer forms a Cu(I) adduct which the mer isomer does not. Alkylation of the pyrazolyl NH group with methyl iodide or benzyl bromide afforded [Ru(L(Me))3](2+) and [Ru(L(bz))3](2+) respectively, each as their fac and mer isomers; all were structurally characterised. In the fac isomers the convergent group of pendant -CH2R or -CH3 protons defines a hydrogen-bond donor pocket; in the mer isomer these protons do not converge and any hydrogen-bonding involving these protons is expected to be weaker. For both [Ru(L(Me))3](2+) and [Ru(L(bz))3](2+), NMR titrations with isoquinoline-N-oxide in MeCN revealed weak 1 : 1 binding (K ≈ 1 M(-1)) between the guest and the fac isomer of the complex that was absent with the mer isomer, confirming a difference in the hydrogen-bond donor capabilities of these complexes associated with their differing geometries. The weak binding compared to the cage however occurs because of competition from the anions, which are free to form ion-pairs with the mononuclear complex cations in a way that does not happen in the cage complexes. We conclude that (i) the presence of fac tris-chelate sites in the cage to act as hydrogen-bond donors, and (ii
Sando, Steven K.; Clark, Melanie L.; Cleasby, Thomas E.; Barnhart, Elliott P.
2015-01-01
Trend results for sites in the Tenmile Creek watershed generally are more variable and difficult to interpret than for sites in the Boulder River watershed. Trend results for Tenmile Creek above City Diversion (site 11) and Minnehaha Creek near Rimini (site 12) for water years 2000–13 indicate decreasing trends in FACs of cadmium, copper, and zinc. The magnitudes of the decreasing trends in FACs of copper generally are moderate and statistically significant for sites 11 and 12. The magnitudes of the decreasing trends in FACs of cadmium and zinc for site 11 are minor to small and not statistically significant; however, the magnitudes for site 12 are moderate and statistically significant. In general, patterns in FACs for Tenmile Creek near Rimini (site 13) are not well represented by fitted trends within the short data collection period, which might indicate that the trend-analysis structure of the study is not appropriate for describing trends in FACs for site 13. The large decreasing trend in FACs of suspended sediment is the strongest indication of change in water quality during the short period of record for site 13; however, this trend is not statistically significant.
Spectroscopic Characterization of Aqua [ fac-Tc(CO)3]+ Complexes at High Ionic Strength.
Chatterjee, Sayandev; Hall, Gabriel B; Engelhard, Mark H; Du, Yingge; Washton, Nancy M; Lukens, Wayne W; Lee, Sungsik; Pearce, Carolyn I; Levitskaia, Tatiana G
2018-06-18
Understanding fundamental Tc chemistry is important to both the remediation of nuclear waste and the reprocessing of nuclear fuel; however, current knowledge of the electronic structure and spectral signatures of low-valent Tc compounds significantly lags behind the remainder of the d-block elements. In particular, identification and treatment of Tc speciation in legacy nuclear waste is challenging due to the lack of reference data especially for Tc compounds in the less common oxidation states (I-VI). In an effort to establish a spectroscopic library corresponding to the relevant conditions of extremely high ionic strength typical for the legacy nuclear waste, compounds with the general formula of [ fac-Tc(CO) 3 (OH 2 ) 3- n (OH) n ] 1- n (where n = 0-3) were examined by a range of spectroscopic techniques including 99 Tc/ 13 C NMR, IR, XPS, and XAS. In the series of monomeric aqua species, stepwise hydrolysis results in the increase of the Tc metal center electron density and corresponding progressive decrease of the Tc-C bond distances, Tc electron binding energies, and carbonyl stretching frequencies in the order [ fac-Tc(CO) 3 (OH 2 ) 3 ] + > [ fac-Tc(CO) 3 (OH 2 ) 2 (OH)] > [ fac-Tc(CO) 3 (OH 2 )(OH) 2 ] - . These results correlate with established trends of the 99 Tc upfield chemical shift and carbonyl 13 C downfield chemical shift. The lone exception is [ fac-Tc(CO) 3 (OH)] 4 which exhibits a comparatively low electron density at the metal center attributed to the μ 3 -bridging nature of the - OH ligands causing less σ-donation and no π-donation. This work also reports the first observations of these compounds by XPS and [ fac-Tc(CO) 3 Cl 3 ] 2- by XAS. The unique and distinguishable spectral features of the aqua [ fac-Tc(CO) 3 ] + complexes lay the foundation for their identification in the complex aqueous matrixes.
Agave Chewing and Dental Wear: Evidence from Quids
Hammerl, Emily E.; Baier, Melissa A.; Reinhard, Karl J.
2015-01-01
Agave quid chewing is examined as a potential contributing behavior to hunter-gatherer dental wear. It has previously been hypothesized that the contribution of Agave quid chewing to dental wear would be observed in communities wherever phytolith-rich desert succulents were part of subsistence. Previous analysis of coprolites from a prehistoric agricultural site, La Cueva de los Muertos Chiquitos in Durango, Mexico, showed that Agave was a consistent part of a diverse diet. Therefore, quids recovered at this site ought to be useful materials to test the hypothesis that dental wear was related to desert succulent consumption. The quids recovered from the site were found to be largely derived from chewing Agave. In this study, the quids were found to be especially rich in phytoliths, and analysis of dental casts made from impressions left in the quids revealed flat wear and dental attrition similar to that of Agave-reliant hunter-gatherers. Based on evidence obtained from the analysis of quids, taken in combination with results from previous studies, it is determined that Agave quid chewing was a likely contributing factor to dental wear in this population. As such, our method provides an additional avenue of dental research in areas where quids are present. PMID:26230855
Design of the free-air ionization chamber, FAC-IR-150, for X-ray dosimetry
NASA Astrophysics Data System (ADS)
Mohammadi, Seyed Mostafa; Tavakoli-Anbaran, Hossein
2018-03-01
The primary standard for X-ray dosimetry is based on the free-air ionization chamber (FAC). Therefore, the Atomic Energy Organization of Iran (AEOI) designed the free-air ionization chamber, FAC-IR-150, for low and medium energy X-ray dosimetry. The purpose of this work is the study of the free-air ionization chamber characteristics and the design of the FAC-IR-150. The FAC-IR-150 dosimeter has two parallel plates, a high voltage plate and a collector plate. A guard electrode surrounds the collector and is separated by an air gap. A group of guard strips is used between up and down electrodes to produce a uniform electric field in all the ion chamber volume. This design involves introducing the correction factors and determining the exact dimensions of the ionization chamber by using Monte Carlo simulation.
Lipowska, Malgorzata; He, Haiyang; Xu, Xiaolong; Taylor, Andrew T; Marzilli, Patricia A; Marzilli, Luigi G
2010-04-05
We study Re analogues of (99m)Tc renal agents to interpret previous results at the (99m)Tc tracer level. The relative propensities of amine donors versus carboxylate oxygen donors of four L = polyaminocarboxylate ligands to coordinate in fac-[Re(I)(CO)(3)L](n) complexes were assessed by examining the reaction of fac-[Re(I)(CO)(3)(H(2)O)(3)](+) under conditions differing in acidity and temperature. All four L [N,N-bis-(2-aminoethyl)glycine (DTGH), N,N-ethylenediaminediacetic acid, diethylenetriamine-N-malonic acid, and diethylenetriamine-N-acetic acid] can coordinate as tridentate ligands while creating a dangling chain terminated in a carboxyl group. Dangling carboxyl groups facilitate renal clearance in fac-[(99m)Tc(I)(CO)(3)L](n) agents. Under neutral conditions, the four ligands each gave two fac-[Re(I)(CO)(3)L](n) products with HPLC traces correlating well with known traces of the fac-[(99m)Tc(I)(CO)(3)L](n) mixtures. Such mixtures are common in renal agents because the needed dangling carboxyl group can compete for a coordination site. However, the HPLC separations needed to assess the biodistribution of a single tracer are impractical in a clinical setting. One goal in investigating this Re chemistry is to identify conditions for avoiding this problem of mixtures in preparations of fac-[(99m)Tc(I)(CO)(3)L](n) renal tracers. After separation and isolation of the fac-[Re(I)(CO)(3)L](n) products, NMR analysis of all products and single crystal X-ray crystallographic analysis of both DTGH products, as well as one product each from the other L, allowed us to establish coordination mode unambiguously. The product favored in acidic conditions has a dangling amine chain and more bound oxygen. The product favored in basic conditions has a dangling carboxyl chain and more bound nitrogen. At the elevated temperatures used for simulating tracer preparation, equilibration was facile (ca. 1 h or less), allowing selective formation of one product by utilizing acidic or
Perera, Theshini; Marzilli, Patricia A; Fronczek, Frank R; Marzilli, Luigi G
2010-03-01
To evaluate syntheses of fac-[Re(CO)(3)L](+) complexes in organic solvents, we treated fac-[Re(CO)(3)(CH(3)CN)(3)]PF(6)/BF(4) in acetonitrile with triamine ligands (L). When L had two primary or two tertiary terminal amine groups, the expected fac-[Re(CO)(3)L](+) complexes formed. In contrast, N,N-dimethyldiethylenetriamine (N,N-Me(2)dien) formed an unusual compound, fac-[Re(CO)(3)(DAE)]BF(4) {DAE = (Z)-N'-(2-(2-(dimethylamino)ethylamino)ethyl)acetimidamide = (Me(2)NCH(2)CH(2))NH(CH(2)CH(2)N=C(NH(2))Me)}. DAE is formed by addition of acetonitrile to the N,N-Me(2)dien terminal primary amine, converting this sp(3) nitrogen to an sp(2) nitrogen with a double bond to the original acetonitrile sp carbon. The three Ns bound to Re derive from N,N-Me(2)dien. The pathway to fac-[Re(CO)(3)(DAE)]BF(4) is suggested by a second unusual compound, fac-[Re(CO)(3)(MAE)]PF(6) {MAE = N-methyl-N-(2-(methyl-(2-(methylamino)ethyl)amino)ethyl)acetimidamide = MeN(H)-CH(2)CH(2)-N(Me)-CH(2)CH(2)-N(Me)-C(Me)=NH}, isolated after treating fac-[Re(CO)(3)(CH(3)CN)(3)]PF(6) with N,N',N''-trimethyldiethylenetriamine (N,N',N''-Me(3)dien). MAE chelates via a terminal and a central sp(3) N from N,N',N''-Me(3)dien and via one sp(2) NH in a C(Me)=NH group. This group is derived from acetonitrile by addition of the other N,N',N''-Me(3)dien terminal amine to the nitrile carbon. This addition creates an endocyclic NMe group within a seven-membered chelate ring. The structure and other properties of fac-[Re(CO)(3)(MAE)]PF(6) allow us to propose a reaction scheme for the formation of the unprecedented DAE ligand. The new compounds advance our understanding of the spectral and structural properties of Re analogues of (99m)Tc radiopharmaceuticals.
Free-air ionization chamber, FAC-IR-300, designed for medium energy X-ray dosimetry
NASA Astrophysics Data System (ADS)
Mohammadi, S. M.; Tavakoli-Anbaran, H.; Zeinali, H. Z.
2017-01-01
The primary standard for X-ray photons is based on parallel-plate free-air ionization chamber (FAC). Therefore, the Atomic Energy Organization of Iran (AEOI) is tried to design and build the free-air ionization chamber, FAC-IR-300, for low and medium energy X-ray dosimetry. The main aim of the present work is to investigate specification of the FAC-IR-300 ionization chamber and design it. FAC-IR-300 dosimeter is composed of two parallel plates, a high voltage (HV) plate and a collector plate, along with a guard electrode that surrounds the collector plate. The guard plate and the collector were separated by an air gap. For obtaining uniformity in the electric field distribution, a group of guard strips was used around the ionization chamber. These characterizations involve determining the exact dimensions of the ionization chamber by using Monte Carlo simulation and introducing correction factors.
Tooth wear and wear investigations in dentistry.
Lee, A; He, L H; Lyons, K; Swain, M V
2012-03-01
Tooth wear has been recognised as a major problem in dentistry. Epidemiological studies have reported an increasing prevalence of tooth wear and general dental practitioners see a greater number of patients seeking treatment with worn dentition. Although the dental literature contains numerous publications related to management and rehabilitation of tooth wear of varying aetiologies, our understanding of the aetiology and pathogenesis of tooth wear is still limited. The wear behaviour of dental biomaterials has also been extensively researched to improve our understanding of the underlying mechanisms and for the development of restorative materials with good wear resistance. The complex nature of tooth wear indicates challenges for conducting in vitro and in vivo wear investigations and a clear correlation between in vitro and in vivo data has not been established. The objective was to critically review the peer reviewed English-language literature pertaining to prevalence and aetiology of tooth wear and wear investigations in dentistry identified through a Medline search engine combined with hand-searching of the relevant literature, covering the period between 1960 and 2011. © 2011 Blackwell Publishing Ltd.
Anggadiredja, Kusnandar; Tjandrawinata, Raymond R
2015-01-01
DLBS1425 is a bioactive compound extracted from Phaleria macrocarpa, with anti-proliferative, anti-inflammatory and anti-angiogenic properties against cancer cells. The present study was aimed to assess cardiotoxicity of DLBS1425, compared to the mainstay regimen for breast cancer, 5-fluorouracil:doxorubicin:cyclophosphamide (FAC, given at 500/50/500 mg/m(2)). Treatment with FAC regimen at standard dose resulted in very severe toxicity, so mice had no chance to survive for more than 7 days following initial drug treatment. Furthermore, histological examination on the heart revealed severe muscular damage when mice were given the FAC regimen alone (severe toxicity). FAC as chemotherapeutic regimen exerted high toxicity profile to the cardiovascular cells in this experiment. Meanwhile, treatment with DLBS1425 alone up to a dose equivalent to as high as 300 mg three times daily in human had no hazardous consequences on the heart, hematological feature, as well as general safety. In the cardiovascular cells, DLBS1425 in the presence of FAC regimen (one-eight of the initial dose) gave protection to the cardiac muscle cells as well as other hematological features. Taken together, results of the present study suggest that DLBS1425 is safe when used as adjuvant therapy for breast cancer and may be even protective against cardiac cellular damage produced by chemotherapeutic regimen.
Adams, Kristie M; Marzilli, Patricia A; Marzilli, Luigi G
2007-10-29
Products formed between monoester diphosphates (MDPs) and fac-[Re(CO)3(H2O)3]OTf at pH 3.6 were examined. Such adducts of the fac-[Re(CO)3]+ moiety have an uncommon combination of properties for an "inert" metal center in that sharp NMR signals can be observed, yet the products are equilibrating at rates allowing NMR EXSY cross-peaks to be observed. Thiamine diphosphate (TDP) and uridine 5'-diphosphate (5'-UDP) form 1:1 bidentate {Palpha,Pbeta} chelates, in which the MDP binds Re(I) via Palpha and Pbeta phosphate groups. Asymmetric centers are created at Re(I) (RRe/SRe) and Palpha (Delta/Lambda), leading to four diastereomers. The two mirror pairs of diastereomers (RReDelta/SReLambda) and (RReLambda/SReDelta) for TDP (no ribose) and for all four diastereomers (RReDelta, RReLambda, SReDelta, SReLambda) for 5'-UDP (asymmetric ribose) gave two and four sets of NMR signals for the bound MDP, respectively. 31Palpha-31Palpha EXSY cross-peaks indicate that the fac-[Re(CO)3(H2O)({Palpha,Pbeta}MDP)]- isomers interchange slowly on the NMR time scale, with an average k approximately equal to 0.8 s(-1) at 32 degrees C; the EXSY cross-peaks could arise from chirality changes at only Re(I) or at only Palpha. Guanosine 5'-diphosphate (5'-GDP), with a ribose moiety and a Re(I)-binding base, formed both possible diastereomers (RRe and SRe) of the fac-[Re(CO)3(H2O)({N7,Pbeta}GDP)]- macrochelate, with one slightly more abundant diastereomer suggested to be RRe by Mn2+ ion 1H NMR signal line-broadening combined with distances from molecular models. Interchange of the diastereomers requires that the coordination site of either N7 or Pbeta move to the H2O site. 31Palpha-31Palpha EXSY cross-peaks indicate a k approximately equal to 0.5 s(-1) at 32 degrees C for RRe-to-SRe interchange. The similarity of the rate constants for interchange of fac-[Re(CO)3(H2O)({Palpha,Pbeta}MDP)]- and fac-[Re(CO)3(H2O)({N7,Pbeta}GDP)]- adducts suggest strongly that interchange of Pbeta and H2O coordination
Takayasu, Satoshi; Suzuki, Takayoshi; Shinozaki, Kazuteru
2013-08-15
The intermolecular interaction and aggregation of the neutral complex fac-tris(2-phenylpyridinato-C(2),N)iridium(III) (fac-Ir(ppy)3) in solution was investigated. Intermolecular interactions were found to effectively decrease the luminescence lifetime via self-quenching with increasing fac-Ir(ppy)3 concentrations. A Stern-Volmer plot for quenching in acetonitrile was linear, due to bimolecular self-quenching, but curved in toluene as the result of excimer formation. (1)H NMR spectra demonstrated a monomer-aggregate equilibrium which resulted in spectral shifts depending on solvent polarity. X-ray crystallography provided structural information concerning the aggregate, which is based on a tetramer consisting of two Δ-fac-Ir(ppy)3-Λ-fac-Ir(ppy)3 pairs. Offset π-π stacking of ppy ligands and electrostatic dipole-dipole interactions between complex molecules play an important role in the formation of these molecular pairs.
MAC/FAC: A Model of Similarity-Based Retrieval.
ERIC Educational Resources Information Center
Forbus, Kenneth D.; And Others
1995-01-01
Presents MAC/FAC, a model of similarity-based retrieval that attempts to capture psychological phenomena; discusses its limitations and extensions, its relationship with other retrieval models, and its placement in the context of other work on the nature of similarity. Examines the utility of the model through psychological experiments and…
NASA Astrophysics Data System (ADS)
Cheng, Z. W.; Shi, J. K.; Zhang, J. C.; Torkar, K.; Kistler, L. M.; Dunlop, M.; Carr, C.; Rème, H.; Dandouras, I.; Fazakerley, A.
2018-04-01
The influence of the interplanetary magnetic field (IMF) cone angle θ (the angle between the IMF direction and the Sun-Earth line) on the invariant latitudes of the footprints of the field-aligned currents (FACs) in the magnetotail has been investigated. We performed a statistical study of 542 FAC cases observed by the four Cluster spacecraft in the Northern Hemisphere. The results show that there are almost no FACs when the IMF cone angle is less than 10°, and there are indications of the FACs in the plasma sheet boundary layers being weak under the radial IMF conditions. The footprints of the large FAC (>10 nA/m2) cases are within invariant latitudes <71° and mainly within IMF cone angles θ > 60°, which implies that the footprints of the large FACs mainly expand equatorward with large IMF cone angle. The equatorward boundary of the FAC footprints in the polar region decreases with increasing IMF cone angle (and has a better correlation for northward IMF), which shows that the IMF cone angle plays an important controlling role in FAC distributions in the magnetosphere-ionosphere coupling system. There is almost no correlation between the poleward boundary and the IMF cone angle for both northward and southward IMF. This is because the poleward boundary movement is limited by an enhanced lobe magnetic flux. This is the first time a correlation between FAC footprints in the polar region and IMF cone angles has been determined.
Kapil, Priyanka; MacMillan, Meghan; Carvalho, Maritza; Lymburner, Patricia; Fung, Ron; Almeida, Bernadette; Van Dorn, Laurie; Enright, Katherine
2016-09-01
We aimed to improve the time to antibiotics (TTA) for patients treated with chemotherapy who present to the emergency department (ED) with febrile neutropenia (FN) by using standardized fever advisory cards (FACs). Patients treated with chemotherapy who visited the ED at the Peel Regional Cancer Center in Ontario, Canada, with suspected FN were identified, before (April 2012 to March 2013) and after (October 2013 to March 2014) FAC implementation. The primary outcome of interest was TTA. Additional process measures included Canadian Triage and Acuity Scale score, time to physician assessment, and FAC compliance. Outcomes were analyzed with descriptive statistics and control charts to determine whether the change in primary measures were within statistical control over time. Between the pre-FAC cohort (n = 239) and post-FAC cohort (n = 69), TTA did not change significantly post-FACs (195 v 244 min, P = .09), with monthly averages demonstrating normal variation by statistical process control methodology. The introduction of FACs increased the percentage of patients with correctly assigned Canadian Triage and Acuity Scale scores (87% v 100%) but did not affect time to physician assessment. Compliance with FACs among patients was not ideal, with only 62.5% using them as intended. The distribution of FACs was associated with an improved incidence of correct FN triaging but did not demonstrate a meaningful improvement in the quality of FN management. This may be explained by FAC use among patients not being ideal. Next steps in the continued effort toward high-quality FN care include redesign of FACs, reinforcement of provider and patient education, and ED outreach. Copyright © 2016 by American Society of Clinical Oncology.
TMSOTf assisted synthesis of 2'-deoxy-2'-[18F]fluoro-β-D-arabinofuranosylcytosine ([18F]FAC).
Gangangari, Kishore K; Humm, John L; Larson, Steven M; Pillarsetty, Naga Vara Kishore
2018-01-01
[18F]FAC (2'-deoxy-2'-[18F]fluoro-β-D-arabinofuranosylcytosine, 1) is a versatile probe for imaging deoxycytidine kinase (dCK) expression levels in vivo. dCK is responsible for phosphorylation of deoxycytidine (dC, 2) and other nucleoside analogs, plays a key role in immune activation and has demonstrated to be one of the key enzymes in activating nucleoside based drugs including gemcitabine. Reported synthesis of [18F]FAC is high yielding but is quite challenging requiring bromination using HBr and careful drying of excess HBr which is critical for successful synthesis. Here in we report a simplified trimethylsilyl trifluoromethanesulfonate (TMSOTf) assisted synthesis of [18F]FAC eliminating the need of bromination and drying. [18F]FAC (β-anomer) was synthesized with average isolated decay corrected yield of 10.59 + 4.2% (n = 6) with radiochemical purity of >98% and total synthesis time of 158 + 19 min.
Neblett, Randy; Mayer, Tom G; Williams, Mark J; Asih, Sali; Cuesta-Vargas, Antonio I; Hartzell, Meredith M; Gatchel, Robert J
2017-12-01
To assess the clinical validity and factor structure of the Fear-Avoidance Components Scale (FACS), a new fear-avoidance measure. In this study, 426 chronic musculoskeletal pain disorder patients were admitted to a Functional Restoration Program (FRP). They were categorized into 5 FACS severity levels, from subclinical to extreme, at admission, and again at discharge. Associations with objective lifting performance and other patient-reported psychosocial measures were determined at admission and discharge, and objective work outcomes for this predominantly disabled cohort, were assessed 1 year later. Those patients in the severe and extreme FACS severity groups at admission were more likely to "drop out" of treatment than those in the lower severity groups (P=0.05). At both admission and discharge, the FACS severity groups were highly and inversely correlated with objective lifting performance and patient-reported fear-avoidance-related psychosocial variables, including kinesiophobia, pain intensity, depressive symptoms, perceived disability, perceived injustice, and insomnia (Ps<0.001). All variables showed improvement at FRP discharge. Patients in the extreme FACS severity group at discharge were less likely to return to, or retain, work 1 year later (P≤0.02). A factor analysis identified a 2-factor solution. Strong associations were found among FACS scores and other patient-reported psychosocial and objective lifting performance variables at both admission and discharge. High discharge-FACS scores were associated with worse work outcomes 1 year after discharge. The FACS seems to be a valid and clinically useful measure for predicting attendance, physical performance, distress, and relevant work outcomes in FRP treatment of chronic musculoskeletal pain disorder patients.
Zhu, Lian; Zhou, Wei; Kong, Peng-Cheng; Wang, Mei-Shan; Zhu, Yan; Feng, Li-Xin; Chen, Xue-Jin; Jiang, Man-Xi
2015-06-01
Round spermatid injection (ROSI) into mammalian oocytes can result in the development of viable embryos and offspring. One current limitation to this technique is the identification of suitable round spermatids. In the current paper, round spermatids were selected from testicular cells with phase contrast microscopy (PCM) and fluorescence-activated cell sorting (FACS), and ROSI was performed in two strains of mice. The rates of fertilization, embryonic development and offspring achieved were the same in all strains. Significantly, round spermatids selected by PCM and FACS were effectively used to rescue the infertile Pten-null mouse. The current results indicate that FACS selection of round spermatids can not only provide high-purity and viable round spermatids for use in ROSI, but also has no harmful effects on the developmental capacity of subsequently fertilized embryos. It was concluded that round spermatids selected by FACS are useful for mouse strain rederivation and rescue of infertile males; ROSI should be considered as a powerful addition to the armamentarium of assisted reproduction techniques applicable in the mouse.
Nicholson, T L; Mahmood, A; Refosco, F; Tisato, F; Müller, P; Jones, A G
2009-08-01
The nitrosyl complex H[TcNOCl(4)] reacts with the tridentate ligand bis[(2-diphenylphosphino)propyl]amine (PNPpr) to yield a mixture of the mer or fac isomers of [TcCl(2)(NO)(PNPpr)]. In acetonitrile, where the ligand is freely soluble, reaction occurs at room temperature to yield mostly the mer isomer with the linear nitrosyl ligand cis to the amine ligand; and the phosphine ligands arranged in a mutually trans orientation. The reaction in methanol requires reflux to dissolve the lipophilic ligand and generates the fac isomer of [TcCl2(NO)(PNPpr)] as the major product, with the tridentate ligand in a facial arrangement, leaving the chlorides and nitrosyl ligand in the remaining facial sites. The steric bulk of the tridentate ligand's diphenylphophino- moieties results in a significant distortion from octahedral geometry, with the P-Tc-P bond angle expanded to 99.48(4)°. The infrared spectra display absorptions from these nitrosyl ligands in the 1700 and 1800 cm(-1) regions for the fac and mer isomers respectively. The ESI(+) mass spectra each display the parent ion at 647 m/z.
Lu, Jia; Xu, Fang; Wang, Deju; Huang, Jue; Cai, Weimin
2009-06-15
Silicalite-1/fly ash cenosphere (S/FAC) zeolite composite has been applied for batch adsorption of methyl tert-butyl ether (MTBE) from water systems. Here the key experimental conditions, including the ratio of initial MTBE concentration to the amount weight of S/FAC, adsorption time and temperature, have been discussed in detail. The results show that approximately 93-95% MTBE could be adsorbed with initial concentration of MTBE solution 1000 microg l(-1). The column flow-through experiments also prove the high capacity of S/FAC composite for MTBE removal. The distinct advantages of S/FAC zeolite composite as adsorbent lie in (1) enhanced adsorption rate and capacity based on hierarchical micro and meso/macroporosity of S/FAC; (2) more easily operation and recycling process by assembly of nano-sized silicalite-1 zeolite on FAC support.
USDA-ARS?s Scientific Manuscript database
Fatty acid amino acid conjugates (FACs) are known elicitors of induced release of volatile compounds in plants that, in turn, attract foraging parasitoids. Since the discovery of volicitin [N-(17-hydroxylinolenoyl)-L-glutamine] in the regurgitant of larval Spodoptera exigua1, a series of related FAC...
Yoshinaga, Naoko; Abe, Hiroaki; Morita, Sayo; Yoshida, Tetsuya; Aboshi, Takako; Fukui, Masao; Tumlinson, James H.; Mori, Naoki
2013-01-01
Fatty acid amino acid conjugates (FACs), first identified in lepidopteran caterpillar spit as elicitors of plant volatile emission, also have been reported as major components in gut tracts of Drosophila melanogaster and cricket Teleogryllus taiwanemma. The profile of FAC analogs in these two insects was similar to that of tobacco hornworm Manduca sexta, showing glutamic acid conjugates predominantly over glutamine conjugates. The physiological function of FACs is presumably to enhance nitrogen assimilation in Spodoptera litura larvae, but in other insects it is totally unknown. Whether these insects share a common synthetic mechanism of FACs is also unclear. In this study, the biosynthesis of FACs was examined in vitro in five lepidopteran species (M. sexta, Cephonodes hylas, silkworm, S. litura, and Mythimna separata), fruit fly larvae and T. taiwanemma. The fresh midgut tissues of all of the tested insects showed the ability to synthesize glutamine conjugates in vitro when incubated with glutamine and sodium linolenate. Such direct conjugation was also observed for glutamic acid conjugates in all the insects but the product amount was very small and did not reflect the in vivo FAC patterns in each species. In fruit fly larvae, the predominance of glutamic acid conjugates could be explained by a shortage of substrate glutamine in midgut tissues, and in M. sexta, a rapid hydrolysis of glutamine conjugates has been reported. In crickets, we found an additional unique biosynthetic pathway for glutamic acid conjugates. T. taiwanemma converted glutamine conjugates to glutamic acid conjugates by deaminating the side chain of the glutamine moiety. Considering these findings together with previous results, a possibility that FACs in these insects are results of convergent evolution cannot be ruled out, but it is more likely that the ancestral insects had the glutamine conjugates and crickets and other insects developed glutamic acid conjugates in a different way. PMID
NASA Astrophysics Data System (ADS)
Cheng, Z.; Shi, J.; Zhang, J.; Kistler, L. M.
2017-12-01
The influence of the interplanetary magnetic field (IMF) cone angle θ (the angle between the IMF direction and the Sun-Earth line) on the invariant latitudes (ILATs) of the footprints of the field-aligned currents (FACs) in the magnetotail has been investigated. We performed a statistic study of 542 FAC cases observed by the four Cluster spacecraft in the northern hemisphere. The results show that the large FAC (>10 nA/m2) cases occur at the low ILATs (<71 º) and mainly occur when the IMF cone angle θ>60º, which implies the footprints of the large FACs mainly expand equatorward with large IMF cone angle. The equatorward boundary of the FAC footprints in the polar region decreases with the IMF cone angle especially when IMF Bz is positive. There is almost no correlation or a weak positive correlation of the poleward boundary and IMF cone angle no matter IMF is northward or southward. The equatorward boundary is more responsive to the IMF cone angle. Compared to the equatorward boundary, the center of the FAC projected location changes very little. This is the first time a correlation between FAC projected location and IMF cone angle has been determined.
McDonald, Aidan R; Lutz, Martin; von Chrzanowski, Lars S; van Klink, Gerard P M; Spek, Anthony L; van Koten, Gerard
2008-08-04
We have developed techniques which allow for covalent tethering, via a "hetero" cyclometallating ligand, of heteroleptic tris-cyclometallated iridium(III) complexes to polymeric supports (for application in light-emitting diode technologies). This involved the selective synthesis and thorough characterization of heteroleptic [Ir(C,N) 2(C',N')] tris-cyclometallated iridium(III) complexes. Furthermore, the synthesis and characterization of heteroleptic [Ir(C,N) 2OR] complexes is presented. Under standard thermal conditions for the synthesis of the facial ( fac) isomer of tris-cyclometallated complexes, it was not possible to synthesize pure heteroleptic complexes of the form [Ir(C,N) 2(C',N')]. Instead, a mixture of homo- and heteroleptic complexes was acquired. It was found that a stepwise procedure involving the synthesis of a pure meridonial ( mer) isomer followed by photochemical isomerization of this mer to the fac isomer was necessary to synthesize pure fac-[Ir(C,N) 2(C',N')] complexes. Under thermal isomerization conditions, the conversion of mer-[Ir(C,N) 2(C',N')] to fac-[Ir(C,N) 2(C',N')] was also not a clean reaction, with again a mixture of homo- and heteroleptic complexes acquired. An investigation into the thermal mer to fac isomerization of both homo- and heteroleptic tris-cyclometallated complexes is presented. It was found that the process is an alcohol-catalyzed reaction with the formation of an iridium alkoxide [Ir(C,N) 2OR] intermediate in the isomerization process. This catalyzed reaction can be carried out between 50 and 100 degrees C, the first such example of low-temperature mer-fac thermal isomerization. We have synthesized analogous complexes and have shown that they do indeed react so as to give fac-tris-cyclometallated products. A detailed explanation of the intermediates (and all of their stereoisomers, in particular when systems of the generic formula [M(a,b) 2(a',b')] are synthesized) formed in the mer to fac isomerization process is
Yang, Y; Bailey, C; Holz, F G; Eter, N; Weber, M; Baker, C; Kiss, S; Menchini, U; Ruiz Moreno, J M; Dugel, P; Lotery, A
2015-09-01
Diabetic macular oedema (DMO) is a leading cause of blindness in working-age adults. Slow-release, nonbioerodible fluocinolone acetonide (FAc) implants have shown efficacy in the treatment of DMO; however, the National Institute for Health and Care Excellence recommends that FAc should be used in patients with chronic DMO considered insufficiently responsive to other available therapies only if the eye to be treated is pseudophakic. The goal of this analysis was to examine treatment outcomes in phakic patients who received 0.2 μg/day FAc implant. This analysis of the phase 3 FAME (Fluocinolone Acetonide in Diabetic Macular Edema) data examines the safety and efficacy of FAc implants in patients who underwent cataract extraction before (cataract before implant (CBI) group) or after (cataract after implant (CAI) group) receiving the implant. The data were further examined by DMO duration. Best corrected visual acuity (BCVA) after 36 months was comparable in the CAI and CBI groups. Both the percentage of patients gaining ≥ 3 lines of vision and mean change in BCVA letter score were numerically greater in the CAI group. In addition, most patients who underwent cataract surgery experienced a net gain in BCVA from presurgery baseline as well as from original study baseline. These data support the use of 0.2 μg/day FAc implants in phakic as well as in pseudophakic patients. These findings will serve as a pilot for design of future studies to evaluate the potential protective effect of FAc implants before cataract surgery in patients with DMO and cataract.
Yang, Y; Bailey, C; Holz, F G; Eter, N; Weber, M; Baker, C; Kiss, S; Menchini, U; Ruiz Moreno, J M; Dugel, P; Lotery, A
2015-01-01
Purpose Diabetic macular oedema (DMO) is a leading cause of blindness in working-age adults. Slow-release, nonbioerodible fluocinolone acetonide (FAc) implants have shown efficacy in the treatment of DMO; however, the National Institute for Health and Care Excellence recommends that FAc should be used in patients with chronic DMO considered insufficiently responsive to other available therapies only if the eye to be treated is pseudophakic. The goal of this analysis was to examine treatment outcomes in phakic patients who received 0.2 μg/day FAc implant. Methods This analysis of the phase 3 FAME (Fluocinolone Acetonide in Diabetic Macular Edema) data examines the safety and efficacy of FAc implants in patients who underwent cataract extraction before (cataract before implant (CBI) group) or after (cataract after implant (CAI) group) receiving the implant. The data were further examined by DMO duration. Results Best corrected visual acuity (BCVA) after 36 months was comparable in the CAI and CBI groups. Both the percentage of patients gaining ≥3 lines of vision and mean change in BCVA letter score were numerically greater in the CAI group. In addition, most patients who underwent cataract surgery experienced a net gain in BCVA from presurgery baseline as well as from original study baseline. Conclusions These data support the use of 0.2 μg/day FAc implants in phakic as well as in pseudophakic patients. These findings will serve as a pilot for design of future studies to evaluate the potential protective effect of FAc implants before cataract surgery in patients with DMO and cataract. PMID:26113503
Effects of bur wear during implant site preparation: an in vitro study.
Scarano, A; Carinci, F; Quaranta, A; Di Iorio, D; Assenza, B; Piattelli, A
2007-01-01
Few studies have investigated the influence of drilling on bone healing. After the drilling of bone and placement of dental implants a sequence begins of cellular and molecular events which represents a combined response of wound healing. The bone healing around dental implants is a complex phenomenon and influences the proliferation and differentiation of pre-osteoblasts into osteoblasts, together with the activation of periosteal and endosteal lining cells, and initiates the production and mineralization of osteoid matrix followed by the organization of the bone-implant interface. The objective of this study is to quantify the temperature changes in cortical bone and marrow spaces during implant site preparation in bovine rib bone. A total 10 harvested bovine ribs and 6 10.5 x 3.5 new drills for implant insertion with external irrigation (Bone System, Milano, Italy) were used in this study. The implant sites were prepared with 10 mm long drills at 500 rpm under abundant external irrigation with saline solution at 37 degrees C. Each drill was used for 10, 30, 60, 90 and 120 implant site preparations; each drill was then observed under SEM for evaluation of the damage of the cutting edge after 10, 30, 60, 90 and 120 preparations. There was an higher and statistically significant increase in the temperature in the cortical bone; this increase in temperature increases with the number of the times of drill use. The drill wear seemed to play a major role in heat production and could explain the observed increased temperature of the bone.
Merola, Joseph S; Franks, Marion A
2015-02-01
The crystal structures of two solvates of fac-tri-chlorido-tris-(tri-methyl-phosphane-κP)rhodium(III) are reported, i.e. one with water in the crystal lattice, fac-[RhCl3(Me3P)3]·H2O, and one with methanol in the crystal lattice, fac-[RhCl3(Me3P)3]·0.5CH3OH. These rhodium compounds exhibit distorted octahedral coordination spheres at the metal and are isotypic with the analogous iridium compounds previously reported by us [Merola et al. (2013 ▶). Polyhedron, 54, 67-73]. Comparison is made between the rhodium and iridium compounds, highlighting their isostructural relationships.
48 CFR 301.607-75 - Maintenance of FAC-P/PM certification.
Code of Federal Regulations, 2010 CFR
2010-10-01
... maintain FAC-P/PM certification, HHS Program and Project Managers are required to earn 80 CLPs of skills...) Training activities, such as teaching, self-directed study, and mentoring; (2) Courses completed to achieve...
Cibian, Mihaela; Bessette, André; O'Connor, Andrew; Ferreira, Janaina G; Hanan, Garry S
2015-02-01
The crystal structures of fac-(acetonitrile-κN)(2-{[3,5-bis(4-methoxyphenyl)-2H-pyrrol-2-ylidene-κN(1)]amino}-3,5-bis(4-methoxyphenyl)-1H-pyrrol-1-ido-κN(1))tricarbonylrhenium(I)-hexane-acetonitrile (2/1/2), [Re(C36H30N3O4)(CH3CN)(CO)3]·0.5C6H14·CH3CN, (2), and fac-(2-{[3,5-bis(4-methoxyphenyl)-2H-pyrrol-2-ylidene-κN(1)]amino}-3,5-bis(4-methoxyphenyl)-1H-pyrrol-1-ido-κN(1))tricarbonyl(dimethyl sulfoxide-κO)rhenium(I), [Re(C36H30N3O4)(C2H6OS)(CO)3], (3), at 150 K are reported. Both complexes display a distorted octahedral geometry, with a fac-Re(CO)3 arrangement and one azadipyrromethene (ADPM) chelating ligand in the equatorial position. One solvent molecule completes the coordination sphere of the Re(I) centre in the remaining axial position. The ADPM ligand shows high flexibility upon coordination, while retaining its π-delocalized nature. Bond length and angle analyses indicate that the differences in the geometry around the Re(I) centre in (2) and (3), and those found in three reported fac-Re(CO)3-ADPM complexes, are dictated mainly by steric factors and crystal packing. Both structures display intramolecular C-H...N hydrogen bonding. Intermolecular interactions of the Csp(2)-H...π and Csp(2)-H...O(carbonyl) types link the discrete monomers into extended chains.
Wear resistance and mechanisms of composite hardfacings at abrasive impact erosion wear
NASA Astrophysics Data System (ADS)
Surzhenkov, A.; Viljus, M.; Simson, T.; Tarbe, R.; Saarna, M.; Casesnoves, F.
2017-05-01
Tungsten carbide based hardmetal containing sprayed and melted composite hardfacings are prospective for protection against abrasive wear. For selection of abrasive wear resistant hardfacings under intensive impact wear conditions, both mechanical properties (hardness, fracture toughness, etc.) and abrasive wear conditions (type of abrasive, impact velocity, etc.) should be considered. This study focuses on the wear (wear rate and mechanisms) of thick metal-matrix composite hardfacings with hardmetal (WC-Co) reinforcement produced by powder metallurgy technology. The influence of the hardmetal reinforcement type on the wear resistance at different abrasive impact erosion wear (AIEW) conditions was studied. An optimal reinforcement for various wear conditions is described. Based on wear mechanism studies, a mathematical model for wear prediction was drafted.
Wagner, James M; Liu, Leqian; Yuan, Shuo-Fu; Venkataraman, Maya V; Abate, Adam R; Alper, Hal S
2018-04-23
Evolutionary approaches to strain engineering inherently require the identification of suitable selection techniques for the product and phenotype of interest. In this work, we undertake a comparative analysis of two related but functionally distinct methods of high-throughput screening: traditional single cell fluorescence activated cell sorting (single cell FACS) and microdroplet-enabled FACS (droplet FACS) using water/oil/water (w/o/w) emulsions. To do so, we first engineer and evolve the non-conventional yeast Yarrowia lipolytica for high extracellular production of riboflavin (vitamin B2), an innately fluorescent product. Following mutagenesis and adaptive evolution, a direct parity-matched comparison of these two selection strategies was conducted. Both single cell FACS and droplet FACS led to significant increases in total riboflavin titer (32 and 54 fold relative to the parental PO1f strain, respectively). However, single cell FACS favored intracellular riboflavin accumulation (with only 70% of total riboflavin secreted) compared with droplet FACS that favored extracellular product accumulation (with 90% of total riboflavin secreted). We find that for the test case of riboflavin, the extent of secretion and total production were highly correlated. The resulting differences in production modes and levels clearly demonstrate the significant impact that selection approaches can exert on final evolutionary outcomes in strain engineering. Moreover, we note that these results provide a cautionary tale when intracellular read-outs of product concentration (including signals from biosensors) are used as surrogates for total production of potentially secreted products. In this regard, these results demonstrate that extracellular production is best assayed through an encapsulation technique when performing high throughput screening. Copyright © 2018 International Metabolic Engineering Society. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Siewiorek, A.; Malczyk, P.; Sobczak, N.; Sobczak, J. J.; Czulak, A.; Kozera, R.; Gude, M.; Boczkowska, A.; Homa, M.
2016-08-01
To develop an optimised manufacturing method of fly ash-reinforced metal matrix composites, the preliminary tests were performed on the cenospheres selected from fly ash (FACS) with halloysite nanotubes (HNTs) addition. The preform made out of FACS with and without the addition of HNT (with 5 and 10 wt.%) has been infiltrated by the pure aluminium (Al) via adapted gas pressure infiltration process. This paper reveals the influence of HNT addition on the microstructure (analysis was done by computed tomography and scanning electron microscopy combined with energy-dispersive x-ray spectroscopy), thermal properties (thermal expansion coefficient, thermal conductivity and specific heat) and the mechanical properties (hardness and compression test) of manufactured composites. The analysis of structure-property relationships for Al/FACS-HNT composites produced shows that the addition of 5 wt.% of HNT to FACS preform contributes to receiving of the best mechanical and structural properties of investigated composites.
Sando, Steven K.; Vecchia, Aldo V.
2016-07-20
) and period 3B (March 28, 2008–September 30, 2010) for the Clark Fork above Missoula (sampling site 22). Trend results were considered statistically significant when the statistical probability level was less than 0.01.In conjunction with the trend analysis, estimated normalized constituent loads (hereinafter referred to as “loads”) were calculated and presented within the framework of a constituent-transport analysis to assess the temporal trends in flow-adjusted concentrations (FACs) in the context of sources and transport. The transport analysis allows assessment of temporal changes in relative contributions from upstream source areas to loads transported past each reach outflow.Trend results indicate that FACs of unfiltered-recoverable copper decreased at the sampling sites from the start of period 1 through the end of period 4; the decreases ranged from large for one sampling site (Silver Bow Creek at Warm Springs [sampling site 8]) to moderate for two sampling sites (Clark Fork near Galen, Montana [sampling site 11] and Clark Fork above Missoula [sampling site 22]) to small for four sampling sites (Clark Fork at Deer Lodge, Montana [sampling site 14], Clark Fork at Goldcreek, Montana [sampling site 16], Clark Fork near Drummond, Montana [sampling site 18], and Clark Fork at Turah Bridge near Bonner, Montana [sampling site 20]). For period 4 (water years 2011–15), the most notable changes indicated for the Milltown Reservoir/Clark Fork River Superfund Site were statistically significant decreases in FACs and loads of unfiltered-recoverable copper for sampling sites 8 and 22. The period 4 changes in FACs of unfiltered-recoverable copper for all other sampling sites were not statistically significant.Trend results indicate that FACs of unfiltered-recoverable arsenic decreased at the sampling sites from period 1 through period 4 (water years 1996–2015); the decreases ranged from minor (sampling sites 8–20) to small (sampling site 22). For period 4 (water
TMSOTf assisted synthesis of 2’-deoxy-2’-[18F]fluoro-β-D-arabinofuranosylcytosine ([18F]FAC)
Humm, John L.; Larson, Steven M.; Pillarsetty, Naga Vara Kishore
2018-01-01
[18F]FAC (2’-deoxy-2’-[18F]fluoro-β-D-arabinofuranosylcytosine, 1) is a versatile probe for imaging deoxycytidine kinase (dCK) expression levels in vivo. dCK is responsible for phosphorylation of deoxycytidine (dC, 2) and other nucleoside analogs, plays a key role in immune activation and has demonstrated to be one of the key enzymes in activating nucleoside based drugs including gemcitabine. Reported synthesis of [18F]FAC is high yielding but is quite challenging requiring bromination using HBr and careful drying of excess HBr which is critical for successful synthesis. Here in we report a simplified trimethylsilyl trifluoromethanesulfonate (TMSOTf) assisted synthesis of [18F]FAC eliminating the need of bromination and drying. [18F]FAC (β-anomer) was synthesized with average isolated decay corrected yield of 10.59 + 4.2% (n = 6) with radiochemical purity of >98% and total synthesis time of 158 + 19 min. PMID:29715301
Wear simulation of resin composites and the relationship to clinical wear.
Barkmeier, Wayne W; Latta, Mark A; Erickson, Robert L; Wilwerding, Terry M
2008-01-01
This study used a new generalized wear model to examine the relationship between wear simulation and the clinical wear of two resin composites. Ten specimens each of P50 and Z100, were subjected to 100,000, 400,000 and 800,000 cycles in a spring-loaded piston-type wear simulator. Wear was generated using flat, cylindrically-shaped stainless steel antagonists on the resin composites, which were placed in custom stainless steel fixtures. A slurry of polymethyl methacrylate beads was used as the abrasive media. Wear was determined using profilometry, and the parameters examined included volume loss (mm3), maximum depth (microm), mean maximum depth (microm) and mean depth (microm). Statistical analysis of the laboratory wear data using ANOVA and Tukey's post hoc test showed a significant difference (p<0.05) for wear between the two materials and the number of cycles. Mean maximum wear (microm) values (100K--P50--11.5 +/- 1.8; Z100--4.9 +/- 1.0; 400K--P50--17.2 +/- 2.7; Z100--6.0 +/- 1.7; 800K--P50--20.5 +/- 4.6; Z100--9.6 +/- 2.5) were used for comparisons with clinical data. Previous clinical studies of P50 and Z100 were used to examine the relationship between laboratory and clinical wear. Linear regression analysis was used to predict laboratory and clinical wear rates. The laboratory wear rate for P50 was 1.3 microm/100K cycles and the rate for Z100 was 0.7 microm/100K cycles. The clinical wear rates for P50 and Z100 were 8.3 microm/year and 4.0 microm/year, respectively. The ratio of wear rates of P50 to Z100 for wear simulation was 1.9 and the ratio of P50 to Z100 for clinical rates was 2.1. These ratios showed good agreement between the relative wear rates of laboratory and clinical wear. For the two composite materials examined, this new simulation model appears to be effective for evaluating the relative wear of resin composites.
Pattern of seat belt wearing in Nanjing, China
Routley, V; Ozanne‐Smith, J; Li, D; Hu, X; Wang, P; Qin, Y
2007-01-01
Objective To describe the patterns of seat belt wearing in Nanjing, China for drivers, front seat passengers, and rear occupants of motor vehicles. Design Roadside observational study. Setting Four sites in central and northern Nanjing during daylight hours over 1 week in April 2005. Subjects Drivers and passengers of 17 147 cars, taxis, goods vans, and pickups, which traveled in the inside traffic lane. Main outcome measures Percentage seat belt wearing for each of seating position, age/sex, time of day, vehicle type, day of week. Results The rate of seat belt wearing was significantly higher in drivers (67.3%, 95% CI 66.6 to 68.0) than front seat passengers (18.9%, 95% CI, 18.0 to 19.8). It was negligible for second front seat passengers (2.6%, 95% CI 0.3 to 4.9) and rear seat passengers (0.5%, 95% CI 0.3 to 0.7). Belt tampering, such that protection would be reduced in the event of a crash, was observed for 18.5% of taxi drivers. Drivers were most likely to wear seat belts in cars and vans and at a city roundabout; front seat passengers were most likely to wear seat belts in non‐taxi vehicles, during the evening rush hour, if the driver was wearing a belt, and on the local north road. Drivers were least likely to wear a belt in the early morning, in pickups and taxis, on Tuesday (or the following week), and on the local north road; front seat passengers were least likely to wear a belt in taxis and if the driver was not wearing a belt. Conclusions Rates of seat belt wearing by passengers were low despite national legislation and provincial regulations coming into effect several months before the survey. Combined education and enforcement are necessary accompaniments to legislation. PMID:18056315
Benny, Paul D; Fugate, Glenn A; Barden, Adam O; Morley, Jennifer E; Silva-Lopez, Elsa; Twamley, Brendan
2008-04-07
Reaction of [NEt4]2[ReBr3(CO)3] with 2,4-pentanedione (acac) yields a complex of the type fac-Re(acac)(OH2)(CO)3 (1) under aqueous conditions. 1 was further reacted with a monodentate ligand (pyridine) to yield a fac-Re(acac)(pyridine)(CO)3 complex (2). Complex 1 was found to react with primary amines to generate a Schiff base (imine) in aqueous solutions. When a mixed-nitrogen donor bidentate ligand, 2-(2-aminoethyl)pyridine, that has different coordination affinities for fac-Re(acac)(OH2)(CO)3 was utilized, a unique tridentate ligand was formed in situ utilizing a metal-assisted Schiff base formation to yield a complex fac-Re(CO)3(3[(2-phenylethyl)imino]-2-pentanone) (3). Tridentate ligand formation was found to occur only with the Re-coordinated acac ligand. Reactions of acac with fac-Re(CO)3Br(2-(2-aminoethyl)pyridine) (4) or a mixture of [NEt4]2[ReBr3(CO)3], acac, and 2-(2-aminoethyl)pyridine did not yield the formation of complex 3 in water.
Evaluation of composite wear with a new multi-mode oral wear simulator.
Condon, J R; Ferracane, J L
1996-07-01
The goals of this study were to develop a machine which simultaneously produces wear through the two main oral wear mechanisms of abrasion and attrition by the action of an enamel antagonist and to compare the results obtained for dental composites using this machine to those obtained from clinical studies and other in vitro studies. The accuracy of this new wear tester was determined by examining 11 commercial composite filling materials and 1 amalgam. Specimens were subjected to three-body abrasion and attrition wear for 50,000 cycles. Profilometry was used to quantitate wear of the composites. Linear regression analysis was used to correlate the results to those obtained from clinical studies, as well as from other in vitro wear testers. The area of enamel wear was also determined by image analysis. The SEM was used to evaluate the wear surfaces. The lowest abrasion wear was recorded for the amalgam and for the microfill and smaller-particle composites. Attrition wear was enhanced for the microfill composites and one small-particle hybrid. There was a strong correlation between the results obtained with the new wear tester and those obtained in the clinical trials cited in the literature. Wear of the enamel antagonist was the greatest for the composites with the largest particle sizes. The wear tester showed a reasonable correlation with other wear-producing machines. A new wear tester developed to evaluate and discriminate abrasion and attrition wear provided results similar to those reported in the literature for a variety of commercial composites. The new machine is capable of characterizing the behavior of a material in multiple wear modes simultaneously with one simple, realistic test.
Dental wear, wear rate, and dental disease in the African apes.
Elgart, Alison A
2010-06-01
The African apes possess thinner enamel than do other hominoids, and a certain amount of dentin exposure may be advantageous in the processing of tough diets eaten by Gorilla. Dental wear (attrition plus abrasion) that erodes the enamel exposes the underlying dentin and creates additional cutting edges at the dentin-enamel junction. Hypothetically, efficiency of food processing increases with junction formation until an optimal amount is reached, but excessive wear hinders efficient food processing and may lead to sickness, reduced fecundity, and death. Occlusal surfaces of molars and incisors in three populations each of Gorilla and Pan were videotaped and digitized. The quantity of incisal and molar occlusal dental wear and the lengths of dentin-enamel junctions were measured in 220 adult and 31 juvenile gorilla and chimpanzee skulls. Rates of dental wear were calculated in juveniles by scoring the degree of wear between adjacent molars M1 and M2. Differences were compared by principal (major) axis analysis. ANOVAs compared means of wear amounts. Pearson correlation coefficients were calculated to compare the relationship between molar wear and incidence of dental disease. Results indicate that quantities of wear are significantly greater in permanent incisors and molars and juvenile molars of gorillas compared to chimpanzees. The lengths of dentin-enamel junctions were predominantly suboptimal. Western lowland gorillas have the highest quantities of wear and the most molars with suboptimal wear. The highest rates of wear are seen in Pan paniscus and Pan t. troglodytes, and the lowest rates are found in P.t. schweinfurthii and G. g. graueri. Among gorillas, G. b. beringei have the highest rates but low amounts of wear. Coefficients between wear and dental disease were low, but significant when all teeth were combined. Gorilla teeth are durable, and wear does not lead to mechanical senescence in this sample.
MAC/FAC: A Model of Similarity-Based Retrieval
1994-10-01
Grapes (0.28) 327 Sour Grapes, analog The Taming of the Shrew (0.22), Merry Wives 251 (0.18), S[11 stories], Sour Grapes (-0.19) Sour Grapes, literal... The Institute for the 0 1 Learning Sciences Northwestern University CD• 00 MAC/FAC: A MODEL OF SIMILARITY-BASED RETRIEVAL Kenneth D. Forbus Dedre...Gentner Keith Law Technical Report #59 • October 1994 94-35188 wit Establisthed in 1989 with the support of Andersen Consulting Form Approved REPORT
Identification and enumeration of staphylococci from the eye during soft contact lens wear.
Leitch, E C; Harmis, N Y; Corrigan, K M; Willcox, M D
1998-04-01
An extensive study was conducted to identify and enumerate staphylococcal microbiota found on ocular sites during asymptomatic soft contact lens (SCL) wear. A biochemical identification system separately grouped the eight clinically relevant staphylococci. Total counts and isolation frequencies from SCLs and ocular sites were evaluated. The epidermidis group was the most numerous isolate from extended wear (EW) lenses; the capitis/warneri group was the most numerous (p < 0.05) from daily wear (DW) lenses. In both DW and EW, the greatest isolation frequency (p < 0.05) was recorded for the capitis/warneri group. The remaining six groups were isolated infrequently and in low numbers. These results show that, in addition to Staphylococcus epidermidis, other staphylococcal species may be important members of the normal microbiota of the ocular surface during SCL wear. Furthermore, an increase and a shift in staphylococcal microbiota between DW and EW regimes was highlighted.
NASA Astrophysics Data System (ADS)
Tanaka, T.; Watanabe, M.; Den, M.; Fujita, S.; Ebihara, Y.; Kikuchi, T.; Hashimoto, K. K.; Kataoka, R.
2016-09-01
In this paper, we try to elucidate the generation mechanism of the field-aligned current (FAC) and coexisting convection. From the comparison between the theoretical prediction and the state of numerical solution from the high-resolution global simulation, we obtain the following conclusions about the distribution of dynamo, the magnetic field structure along the flow path that diverges Poynting flux, and energy conversion promoting the generation of electromagnetic energy. The dynamo for the region 1 FAC, which is in the high-latitude-side cusp-mantle region, has a structure in which magnetic field is compressed along the convection path by the slow mode motion. The dynamo for the region 2 FAC is in the ring current region at the inner edge of the plasma sheet, and has a structure in which magnetic field is curved outward along the convection path. Under these structures, electromagnetic energy is generated from the work done by pressure gradient force, in both dynamos for the region 1 and region 2 FACs. In these generation processes of the FACs, the excitation of convection and the formation of pressure regimes occur as interdependent processes. This structure leads to a modification in the way of understanding the Dungey's convection. Generation of the FAC through the formation of pressure regimes is essential even for the case of substorm onset.
Assessment of wear dependence parameters in complex model of cutting tool wear
NASA Astrophysics Data System (ADS)
Antsev, A. V.; Pasko, N. I.; Antseva, N. V.
2018-03-01
This paper addresses wear dependence of the generic efficient life period of cutting tools taken as an aggregate of the law of tool wear rate distribution and dependence of parameters of this law's on the cutting mode, factoring in the random factor as exemplified by the complex model of wear. The complex model of wear takes into account the variance of cutting properties within one batch of tools, variance in machinability within one batch of workpieces, and the stochastic nature of the wear process itself. A technique of assessment of wear dependence parameters in a complex model of cutting tool wear is provided. The technique is supported by a numerical example.
48 CFR 301.607-75 - Maintenance of FAC-P/PM certification.
Code of Federal Regulations, 2014 CFR
2014-10-01
... document completion of all training. If the required CLPs are not earned within each 2-year period, a FAC-P...) Training activities, such as teaching, self-directed study, and mentoring; (2) Courses completed to achieve... professional seminars/symposia/conferences, publishing papers, and attending workshops; (4) Educational...
48 CFR 301.607-75 - Maintenance of FAC-P/PM certification.
Code of Federal Regulations, 2013 CFR
2013-10-01
... document completion of all training. If the required CLPs are not earned within each 2-year period, a FAC-P...) Training activities, such as teaching, self-directed study, and mentoring; (2) Courses completed to achieve... professional seminars/symposia/conferences, publishing papers, and attending workshops; (4) Educational...
48 CFR 301.607-75 - Maintenance of FAC-P/PM certification.
Code of Federal Regulations, 2011 CFR
2011-10-01
... document completion of all training. If the required CLPs are not earned within each 2-year period, a FAC-P...) Training activities, such as teaching, self-directed study, and mentoring; (2) Courses completed to achieve... professional seminars/symposia/conferences, publishing papers, and attending workshops; (4) Educational...
48 CFR 301.607-75 - Maintenance of FAC-P/PM certification.
Code of Federal Regulations, 2012 CFR
2012-10-01
... document completion of all training. If the required CLPs are not earned within each 2-year period, a FAC-P...) Training activities, such as teaching, self-directed study, and mentoring; (2) Courses completed to achieve... professional seminars/symposia/conferences, publishing papers, and attending workshops; (4) Educational...
Hughes, Michael J; Gerken, Michael; Mercier, Hélène P A; Schrobilgen, Gary J
2010-06-07
Dissolution of the infinite chain polymer, (OsO(3)F(2))(infinity), in CH(3)CN solvent at -40 degrees C followed by solvent removal under vacuum at -40 degrees C yielded fac-OsO(3)F(2)(NCCH(3)).nCH(3)CN (n >/= 2). Continued pumping at -40 degrees C with removal of uncoordinated CH(3)CN yielded fac-OsO(3)F(2)(NCCH(3)). Both fac-OsO(3)F(2)(NCCH(3)).nCH(3)CN and fac-OsO(3)F(2)(NCCH(3)) are yellow-brown solids and were characterized by low-temperature (-150 degrees C) Raman spectroscopy. The crystal structure (-173 degrees C) of fac-OsO(3)F(2)(NCCH(3)).2CH(3)CN consists of two co-crystallized CH(3)CN molecules and a pseudo-octahedral OsO(3)F(2).NCCH(3) molecule in which three oxygen atoms are in a facial arrangement and CH(3)CN is coordinated trans to an oxygen atom in an end-on fashion. The Os---N bond length (2.205(3) A) is among the shortest M---N adduct bonds observed for a d(0) transition metal oxide fluoride. The (19)F NMR spectrum of (OsO(3)F(2))(infinity) in CH(3)CN solvent (-40 degrees C) is a singlet (-99.6 ppm) corresponding to fac-OsO(3)F(2)(NCCH(3)). The (1)H, (15)N, (13)C, and (19)F NMR spectra of (15)N-enriched OsO(3)F(2)(NCCH(3)) were recorded in SO(2)ClF solvent (-84 degrees C). Nitrogen-15 enrichment resulted in splitting of the (19)F resonance of fac-OsO(3)F(2)((15)NCCH(3)) into a doublet ((2)J((15)N-(19)F), 21 Hz). In addition, a doublet of doublets ((2)J((19)F(ax)-(19)F(eq)), 134 Hz; (2)J((15)N-(19)F(eq)), 18 Hz) and a doublet ((2)J((19)F(ax)-(19)F(eq)), 134 Hz) were observed in the (19)F NMR spectrum that have been assigned to mer-OsO(3)F(2)((15)NCCH(3)); however, coupling of (15)N to the axial fluorine-on-osmium environment could not be resolved. The nitrogen atom of CH(3)CN is coordinated trans to a fluorine ligand in the mer-isomer. Quantum-chemical calculations at the SVWN and B3LYP levels of theory were used to calculate the energy-minimized gas-phase geometries, vibrational frequencies of fac- and mer-OsO(3)F(2)(NCCH(3)) and of CH(3)CN. The
Wearing gloves in the hospital
Infection control - wearing gloves; Patient safety - wearing gloves; Personal protective equipment - wearing gloves; PPE - wearing gloves; Nosocomial infection - wearing gloves; Hospital acquired infection - wearing gloves
Understanding wear in dentistry.
Mair, L H
1999-01-01
Tooth wear is an increasing problem in dentistry. Traditionally, it has been divided into three categories: abrasion, attrition, and erosion. However, most clinical cases of tooth wear involve more than one of these processes. It is often easier to make a diagnosis by looking for the signs of the fundamental wear processes rather than trying to categorize the individual case. Wear can be caused by direct surface-to-surface wear, an intervening slurry, or a corrosive environment. Wear occurs during mastication, but also at other times, often at night. Although it may be possible to institute a preventive regimen, this will not always help the patient if his or her prime concern is esthetics. The same processes that cause tooth wear will cause wear to restorative materials. To diagnose and prevent wear, its processes must be understood.
Pontén, Annica; Walsh, Stuart; Malan, Daniela; Xian, Xiaojie; Schéele, Susanne; Tarnawski, Laura; Fleischmann, Bernd K; Jovinge, Stefan
2013-01-01
Purification of cardiomyocytes from the embryonic mouse heart, embryonic stem (ES) or induced pluripotent stem cells (iPS) is a challenging task and will require specific isolation procedures. Lately the significance of surface markers for the isolation of cardiac cell populations with fluorescence activated cell sorting (FACS) has been acknowledged, and the hunt for cardiac specific markers has intensified. As cardiomyocytes have traditionally been characterized by their expression of specific transcription factors and structural proteins, and not by specific surface markers, this constitutes a significant bottleneck. Lately, Flk-1, c-kit and the cellular prion protein have been reported to specify cardiac progenitors, however, no surface markers have so far been reported to specify a committed cardiomyocyte. Herein show for the first time, that embryonic cardiomyocytes can be isolated with 98% purity, based on their expression of vascular cell adhesion molecule-1 (VCAM-1). The FACS-isolated cells express phenotypic markers for embryonic committed cardiomyocytes but not cardiac progenitors. An important aspect of FACS is to provide viable cells with retention of functionality. We show that VCAM-1 positive cardiomyocytes can be isolated with 95% viability suitable for in vitro culture, functional assays or expression analysis. In patch-clamp experiments we provide evidence of functionally intact cardiomyocytes of both atrial and ventricular subtypes. This work establishes that cardiomyocytes can be isolated with a high degree of purity and viability through FACS, based on specific surface marker expression as has been done in the hematopoietic field for decades. Our FACS protocol represents a significant advance in which purified populations of cardiomyocytes may be isolated and utilized for downstream applications, such as purification of ES-cell derived cardiomyocytes.
Pontén, Annica; Walsh, Stuart; Malan, Daniela; Xian, Xiaojie; Schéele, Susanne; Tarnawski, Laura; Fleischmann, Bernd K.; Jovinge, Stefan
2013-01-01
Purification of cardiomyocytes from the embryonic mouse heart, embryonic stem (ES) or induced pluripotent stem cells (iPS) is a challenging task and will require specific isolation procedures. Lately the significance of surface markers for the isolation of cardiac cell populations with fluorescence activated cell sorting (FACS) has been acknowledged, and the hunt for cardiac specific markers has intensified. As cardiomyocytes have traditionally been characterized by their expression of specific transcription factors and structural proteins, and not by specific surface markers, this constitutes a significant bottleneck. Lately, Flk-1, c-kit and the cellular prion protein have been reported to specify cardiac progenitors, however, no surface markers have so far been reported to specify a committed cardiomyocyte. Herein show for the first time, that embryonic cardiomyocytes can be isolated with 98% purity, based on their expression of vascular cell adhesion molecule-1 (VCAM-1). The FACS-isolated cells express phenotypic markers for embryonic committed cardiomyocytes but not cardiac progenitors. An important aspect of FACS is to provide viable cells with retention of functionality. We show that VCAM-1 positive cardiomyocytes can be isolated with 95% viability suitable for in vitro culture, functional assays or expression analysis. In patch-clamp experiments we provide evidence of functionally intact cardiomyocytes of both atrial and ventricular subtypes. This work establishes that cardiomyocytes can be isolated with a high degree of purity and viability through FACS, based on specific surface marker expression as has been done in the hematopoietic field for decades. Our FACS protocol represents a significant advance in which purified populations of cardiomyocytes may be isolated and utilized for downstream applications, such as purification of ES-cell derived cardiomyocytes. PMID:24386094
NASA Astrophysics Data System (ADS)
Danov, Dimitar
2008-02-01
The statistical field-aligned current (FAC) distribution has been demonstrated by [Iijima, T., Potemra, T.A., 1976. The amplitude distribution of field-aligned currents at northern high latitudes observed by Triad. Journal of Geophysical Research 81(13), 2165-2174] and many other authors. The large-scale (LS) FACs have been described by different empirical/statistical models [Feldstein, Ya. I., Levitin, A.E., 1986. Solar wind control of electric fields and currents in the ionosphere. Journal of Geomagnetism and Geoelectricity 38, 1143; Papitashvili, V.O., Rich, F.J., Heinemann, M.A., Hairston, M.R., 1999. Parameterization of the Defense Meteorological Satellite Program ionospheric electrostatic potentials by the interplanetary magnetic field strength and direction. Journal of Geophysical Research 104, 177-184; Papitashvili, V.O., Christiansen, F., Neubert, T., 2002. A new model of field-aligned currents derived from high-precision satellite magnetic field data. Geophysical Research Letters, 29(14), 1683, doi:10.1029/2001GL014207; Tsyganenko, N.A., 2001. A model of the near magnetosphere with a dawn-dusk asymetry (I. Mathematical structure). Journal of Geophysical Research 107(A8), doi:10.1029/2001JA000219; Weimer, D.R., 1996a. A new model for prediction of ionospheric electric potentials as a function of the IMF. In: Snowmass'96 Online Poster Session; Weimer, D.R., 1996b. Substorm influence on the ionospheric convection patterns. In: Snowmass'96 Online Poster Session; Weimer, D.R., 2001. Maps of ionospheric field-aligned currents as a function of the interplanetary magnetic field derived from Dynamic Explorer 2 data. Journal of Geophysical Research 106, 12,889-12,902; Weimer, D.R., 2005. Improved ionospheric electrodynamic models and application to calculating Joule heating rates. Journal of Geophysical Research 110, A05306, doi:10.1029/2004JA010884]. In the present work, we compare two cases of LS FAC obtained from magnetic field measurements onboard the
Koottathape, Natthavoot; Takahashi, Hidekazu; Finger, Wernerj; Kanehira, Masafumi; Iwasaki, Naohiko; Aoyagi, Yujin
2012-06-01
Although attritive and abrasive wear of recent composite resins has been substantially reduced, in vitro wear testing with reasonably simulating devices and quantitative determination of resulting wear is still needed. Three-dimensional scanning methods are frequently used for this purpose. The aim of this trial was to compare maximum depth of wear and volume loss of composite samples, evaluated with a contact profilometer and a non-contact CCD camera imaging system, respectively. Twenty-three random composite specimens with wear traces produced in a ball-on-disc sliding device, using poppy seed slurry and PMMA suspension as third-body media, were evaluated with the contact profilometer (TalyScan 150, Taylor Hobson LTD, Leicester, UK) and with the digital CCD microscope (VHX1000, KEYENCE, Osaka, Japan). The target parameters were maximum depth of the wear and volume loss.Results - The individual time of measurement needed with the non-contact CCD method was almost three hours less than that with the contact method. Both, maximum depth of wear and volume loss data, recorded with the two methods were linearly correlated (r(2) > 0.97; p < 0.01). The contact scanning method and the non-contact CCD method are equally suitable for determination of maximum depth of wear and volume loss of abraded composite resins.
Polyethylene wear debris in modular acetabular prostheses.
Chen, P C; Mead, E H; Pinto, J G; Colwell, C W
1995-08-01
The longevity of total hip arthroplasty has brought forth the recognition of aseptic loosening of prosthetic components as the leading cause of implant failure. Modularity of implants, although a significant improvement in versatility, may increase debris formation, a recognized cause of implant failure. This study was designed to measure the relative motion, and to assess the polyethylene wear debris production at the interface between the metal acetabular shell and the back side of the polyethylene liner, in modular hip prostheses. Five models from 4 manufacturers with different locking mechanisms and acetabular shell surface treatments were tested under long-term simultaneous sinusoidal and static loading (10(7) cycles at 3 Hz with +/- 2.5 Nmeter and 220 N static load). Results showed that there were marked differences in the security of the acetabular shell and polyethylene liner locking mechanism, wear pattern, damage sites, and amount of polyethylene debris on the acetabular shell and polyethylene liner surfaces. The range of polyethylene liner motion observed among the 5 models during 1 cycle of testing varied from an average of 0.96 degrees to movement too small to be detected by the test machines. Image and scanning electron microscopy analysis showed different wear patterns and a wide range in the average polyethylene liner surface wear area (0.26 cm2-4.61 cm2). In general, a stable locking mechanism and a smooth acetabular shell surface are essential in minimizing polyethylene liner wear and polyethylene debris production.
Lima, Carlos F R A C; Taveira, Ricardo J S; Costa, José C S; Fernandes, Ana M; Melo, André; Silva, Artur M S; Santos, Luís M N B F
2016-06-28
Tris(8-hydroxyquinolinate) metallic complexes, Mq3, are one of the most important classes of organic semiconductor materials. Herein, the nature of the chemical bond in Mq3 complexes and its implications on their molecular properties were investigated by a combined experimental and computational approach. Various Mq3 complexes, resulting from the alteration of the metal and substitution of the 8-hydroxyquinoline ligand in different positions, were prepared. The mer-/fac-isomerism in Mq3 was explored by FTIR and NMR spectroscopy, evidencing that, irrespective of the substituent, mer- and fac-are the most stable molecular configurations of Al(iii) and In(iii) complexes, respectively. The relative M-ligand bond dissociation energies were evaluated experimentally by electrospray ionization tandem mass spectrometry (ESI-MS-MS), showing a non-monotonous variation along the group (Al > In > Ga). The results reveal a strong covalent character in M-ligand bonding, which allows for through-ligand electron delocalization, and explain the preferred molecular structures of Mq3 complexes as resulting from the interplay between bonding and steric factors. The mer-isomer reduces intraligand repulsions, being preferred for smaller metals, while the fac-isomer is favoured for larger metals where stronger covalent M-ligand bonds can be formed due to more extensive through-ligand conjugation mediated by metal "d" orbitals.
A general law of fault wear and its implication to gouge zone evolution
NASA Astrophysics Data System (ADS)
Boneh, Yuval; Reches, Ze'ev
2017-04-01
Fault wear and gouge production are universal components of frictional sliding. Wear models commonly consider fault roughness, normal stress and rock strength, but ignore the effects of gouge presence and slip-velocity. In contrast, our experimental observations indicate that wear continues while gouge layer is fully developed, and that wear-rates vary by orders-of-magnitude during slip along experimental faults made of carbonites, sandstones and granites (Boneh et al., 2013, 2014). We derive here a new universal law for fault wear by incorporating the gouge layer and slip-velocity. Slip between two rock-blocks undergoes a transition from a 'two-body' mode, during which the blocks interact at surface roughness contacts, to 'three-body' mode, during which a gouge layer separates the two blocks. Our wear model considers 'effective roughness' as the mechanism for failure at resisting, interacting sites that control the global wear. The effective roughness is comprised of a time dependent, dynamic asperities which are different in population and scale from original surfaces asperities. The model assumes that the intensity of this failure is proportional to the mechanical impulse, which is the integrated force over loading time at the interacting sites. We use this concept to calculate the wear-rate as function of the impulse-density, which is the ratio [shear-stress/slip-velocity], during fault slip. The compilation of experimental wear-rates in a large range of slip-velocities (10 μm/s - 1 m/s) and normal stresses (0.2 - 200 MPa) reveal very good agreement with the model predictions. The model provides the first explanation why fault slip at seismic velocity, e.g., 1 m/s, generates significantly less wear and gouge than fault slip at creeping velocity. Thus, the model provides a tool to use the gouge thickness of fault-zones for estimation of paleo-velocity. Boneh, Y., Sagy, A., Reches, Z., 2013. Frictional strength and wear-rate of carbonate faults during high
Synthesis of novel CeO2-BiVO4/FAC composites with enhanced visible-light photocatalytic properties.
Zhang, Jin; Wang, Bing; Li, Chuang; Cui, Hao; Zhai, Jianping; Li, Qin
2014-09-01
To utilize visible light more effectively in photocatalytic reactions, a fly ash cenosphere (FAC)-supported CeO2-BiVO4 (CeO2-BiVO4/FAC) composite photocatalyst was prepared by modified metalorganic decomposition and impregnation methods. The physical and photophysical properties of the composite have been characterized by X-ray diffraction (XRD), scanning electron microscope (SEM) and energy dispersive X-ray spectroscopy (EDX), X-ray photoelectron spectroscopy (XPS), and UV-Visible diffuse reflectance spectra. The XRD patterns exhibited characteristic diffraction peaks of both BiVO4 and CeO2 crystalline phases. The XPS results showed that Ce was present as both Ce(4+) and Ce(3+) oxidation states in CeO2 and dispersed on the surface of BiVO4 to constitute a p-n heterojunction composite. The absorption threshold of the CeO2-BiVO4/FAC composite shifted to a longer wavelength in the UV-Vis absorption spectrum compared to the pure CeO2 and pure BiVO4. The composites exhibited enhanced photocatalytic activity for Methylene Blue (MB) degradation under visible light irradiation. It was found that the 7.5wt.% CeO2-BiVO4/FAC composite showed the highest photocatalytic activity for MB dye wastewater treatment. Copyright © 2014. Published by Elsevier B.V.
Dynamic SEM wear studies of tungsten carbide cermets. [friction and wear experiments
NASA Technical Reports Server (NTRS)
Brainard, W. A.; Buckley, D. H.
1975-01-01
Dynamic friction and wear experiments were conducted in a scanning electron microscope. The wear behavior of pure tungsten carbide and composite with 6 and 15 weight percent cobalt binder was examined, and etching of the binder was done to selectively determine the role of the binder in the wear process. Dynamic experiments were conducted as the tungsten carbide (WC) and bonded WC cermet surfaces were transversed by a 50 micron radiused diamond stylus. These studies show that the predominant wear process in WC is fracture initiated by plastic deformation, and the wear of the etched cermets is similar to pure WC. The presence of the cobalt binder reduces both friction and wear. The cementing action of the cobalt reduces granular separation, and promotes a dense polished layer because of its low shear strength film-forming properties. The wear debris generated from unetched surface is approximately the same composition as the bulk.
Brink, Alice; Visser, Hendrik G; Roodt, Andreas
2013-08-05
A series of fac-[Re(N,O'-Bid)(CO)3(L)] (N,O'-Bid = monoanionic bidentate Schiff-base ligands with N,O donor atoms; L = neutral monodentate ligand) has been synthesized, and the methanol substitution reactions have been investigated. The complexes were characterized by NMR, IR, and UV-vis spectroscopy. X-ray crystal structures of the compounds fac-[Re(Sal-mTol)(CO)3(HOCH3)], fac-[Re(Sal-pTol)(CO)3(HOCH3)], fac-[Re(Sal-Ph)(CO)3(HOCH3)], and fac-[Re(Sal-Ph)(CO)3(Py)] (Sal-mTol = 2-(m-tolyliminomethyl)phenolato; Sal-pTol = 2-(p-tolyliminomethyl)phenolato; Sal-Ph = 2-(phenyliminomethyl)phenolato; Py = pyridine) are reported. Significant activation for the methanol substitution is induced by the use of the N,O bidentate ligand as manifested by the second order rate constants, with limiting kinetics being observed for the first time. Rate constants (25 °C) (k1 or k3) and activation parameters (ΔHk‡, kJ mol(-1); ΔSk‡, J K(-1) mol(-1)) from Eyring plots for entering nucleophiles as indicated are as follows: fac-[Re(Sal-mTol)(CO)3(HOCH3)] 3-chloropyridine: (k1) 2.33 ± 0.01 M(-1) s(-1); 85.1 ± 0.6, 48 ± 2; fac-[Re(Sal-mTol)(CO)3(HOCH3)] pyridine: (k1) 1.29 ± 0.02 M(-1) s(-1); 92 ± 2, 66 ± 7; fac-[Re(Sal-mTol)(CO)3(HOCH3)] 4-picoline: (k1) 1.27 ± 0.05 M(-1) s(-1); 88 ± 2, 53 ± 6; (k3) 3.9 ± 0.03 s(-1); 78 ± 8, 30 ± 27; (kf) 1.7 ± 0.02 M(-1) s(-1); 86 ± 2, 49 ± 6; fac-[Re(Sal-mTol)(CO)3(HOCH3)] DMAP (k3) 1.15 ± 0.02 s(-1); 88 ± 2, 52 ± 7. An interchange dissociative mechanism is proposed.
Abrasive wear of ceramic wear protection at ambient and high temperatures
NASA Astrophysics Data System (ADS)
Varga, M.; Adam, K.; Tumma, M.; Alessio, K. O.
2017-05-01
Ceramic wear protection is often applied in abrasive conditions due to their excellent wear resistance. This is especially necessary in heavy industries conveying large amounts of raw materials, e.g. in steel industry. Some plants also require material transport at high temperatures and velocities, making the need of temperature stable and abrasion resistant wear protection necessary. Various types and wear behaviour of ceramic protection are known. Hence, the goal of this study is to identify the best suitable ceramic materials for abrasive conditions in harsh environments at temperatures up to 950°C and severe thermal gradients. Chamottes, known for their excellent thermal shock resistance are compared to high abrasion resistant ceramic wear tiles and a cost efficient cement-bounded hard compound. Testing was done under high-stress three-body abrasion regime with a modified ASTM G65 apparatus enabling for investigations up to ~950°C. Thereto heated abrasive is introduced into the wear track and also preheated ceramic samples were used and compared to ambient temperature experiments. Results indicate a significant temperature influence on chamottes and the hard compound. While the chamottes benefit from temperature increase, the cement-bounded hard compound showed its limitation at abrasive temperatures of 950°C. The high abrasion resistant wear tiles represented the materials with the best wear resistance and less temperature influence in the investigated range.
Salas, Jessica R; Chen, Bao Ying; Wong, Alicia; Cheng, Donghui; Van Arnam, John S; Witte, Owen N; Clark, Peter M
2018-04-26
Immune cell-mediated attack on the liver is a defining feature of autoimmune hepatitis and hepatic allograft rejection. Despite an assortment of diagnostic tools, invasive biopsies remain the only method for identifying immune cells in the liver. We evaluated whether PET imaging with radiotracers that quantify immune activation ( 18 F-FDG and 18 F-FAC) and hepatocyte biology ( 18 F-DFA) can visualize and quantify hepatic infiltrating immune cells and hepatocyte inflammation, respectively, in a preclinical model of autoimmune hepatitis. Methods: Mice treated with Concanavalin A (ConA) to induce a model of autoimmune hepatitis or vehicle were imaged with 18 F-FDG, 18 F-FAC, and 18 F-DFA PET. Immunohistochemistry, digital autoradiography, and ex vivo accumulation assays were used to localize areas of altered radiotracer accumulation in the liver. For comparison, mice treated with an adenovirus to induce a viral hepatitis or vehicle were imaged with 18 F-FDG, 18 F-FAC, and 18 F-DFA PET. 18 F-FAC PET was performed on mice treated with ConA, and vehicle or dexamethasone. Biopsy samples of patients suffering from autoimmune hepatitis were immunostained for deoxycytidine kinase (dCK). Results: Hepatic accumulation of 18 F-FDG and 18 F-FAC was 173% and 61% higher, respectively, and hepatic accumulation of 18 F-DFA was 41% lower in a mouse model of autoimmune hepatitis compared to control mice. Increased hepatic 18 F-FDG accumulation was localized to infiltrating leukocytes and inflamed sinusoidal endothelial cells, increased hepatic 18 F-FAC accumulation was concentrated in infiltrating CD4 and CD8 cells, and decreased hepatic 18 F-DFA accumulation was apparent in hepatocytes throughout the liver. In contrast, viral hepatitis increased hepatic 18 F-FDG accumulation by 109% and decreased hepatic 18 F-DFA accumulation by 20% but had no effect on hepatic 18 F-FAC accumulation (non-significant 2% decrease). 18 F-FAC PET provided a non-invasive biomarker of the efficacy of
2010-01-01
Background Plants trigger and tailor defense responses after perception of the oral secretions (OS) of attacking specialist lepidopteran larvae. Fatty acid-amino acid conjugates (FACs) in the OS of the Manduca sexta larvae are necessary and sufficient to elicit the herbivory-specific responses in Nicotiana attenuata, an annual wild tobacco species. How FACs are perceived and activate signal transduction mechanisms is unknown. Results We used SuperSAGE combined with 454 sequencing to quantify the early transcriptional changes elicited by the FAC N-linolenoyl-glutamic acid (18:3-Glu) and virus induced gene silencing (VIGS) to examine the function of candidate genes in the M. sexta-N. attenuata interaction. The analysis targeted mRNAs encoding regulatory components: rare transcripts with very rapid FAC-elicited kinetics (increases within 60 and declines within 120 min). From 12,744 unique Tag sequences identified (UniTags), 430 and 117 were significantly up- and down-regulated ≥ 2.5-fold, respectively, after 18:3-Glu elicitation compared to wounding. Based on gene ontology classification, more than 25% of the annotated UniTags corresponded to putative regulatory components, including 30 transcriptional regulators and 22 protein kinases. Quantitative PCR analysis was used to analyze the FAC-dependent regulation of a subset of 27 of these UniTags and for most of them a rapid and transient induction was confirmed. Six FAC-regulated genes were functionally characterized by VIGS and two, a putative lipid phosphate phosphatase (LPP) and a protein of unknown function, were identified as important mediators of the M. sexta-N. attenuata interaction. Conclusions The analysis of the early changes in the transcriptome of N. attenuata after FAC elicitation using SuperSAGE/454 has identified regulatory genes involved in insect-specific mediated responses in plants. Moreover, it has provided a foundation for the identification of additional novel regulators associated with this
Gilardoni, Paola A; Schuck, Stefan; Jüngling, Ruth; Rotter, Björn; Baldwin, Ian T; Bonaventure, Gustavo
2010-04-14
Plants trigger and tailor defense responses after perception of the oral secretions (OS) of attacking specialist lepidopteran larvae. Fatty acid-amino acid conjugates (FACs) in the OS of the Manduca sexta larvae are necessary and sufficient to elicit the herbivory-specific responses in Nicotiana attenuata, an annual wild tobacco species. How FACs are perceived and activate signal transduction mechanisms is unknown. We used SuperSAGE combined with 454 sequencing to quantify the early transcriptional changes elicited by the FAC N-linolenoyl-glutamic acid (18:3-Glu) and virus induced gene silencing (VIGS) to examine the function of candidate genes in the M. sexta-N. attenuata interaction. The analysis targeted mRNAs encoding regulatory components: rare transcripts with very rapid FAC-elicited kinetics (increases within 60 and declines within 120 min). From 12,744 unique Tag sequences identified (UniTags), 430 and 117 were significantly up- and down-regulated >or= 2.5-fold, respectively, after 18:3-Glu elicitation compared to wounding. Based on gene ontology classification, more than 25% of the annotated UniTags corresponded to putative regulatory components, including 30 transcriptional regulators and 22 protein kinases. Quantitative PCR analysis was used to analyze the FAC-dependent regulation of a subset of 27 of these UniTags and for most of them a rapid and transient induction was confirmed. Six FAC-regulated genes were functionally characterized by VIGS and two, a putative lipid phosphate phosphatase (LPP) and a protein of unknown function, were identified as important mediators of the M. sexta-N. attenuata interaction. The analysis of the early changes in the transcriptome of N. attenuata after FAC elicitation using SuperSAGE/454 has identified regulatory genes involved in insect-specific mediated responses in plants. Moreover, it has provided a foundation for the identification of additional novel regulators associated with this process.
Blend Shape Interpolation and FACS for Realistic Avatar
NASA Astrophysics Data System (ADS)
Alkawaz, Mohammed Hazim; Mohamad, Dzulkifli; Basori, Ahmad Hoirul; Saba, Tanzila
2015-03-01
The quest of developing realistic facial animation is ever-growing. The emergence of sophisticated algorithms, new graphical user interfaces, laser scans and advanced 3D tools imparted further impetus towards the rapid advancement of complex virtual human facial model. Face-to-face communication being the most natural way of human interaction, the facial animation systems became more attractive in the information technology era for sundry applications. The production of computer-animated movies using synthetic actors are still challenging issues. Proposed facial expression carries the signature of happiness, sadness, angry or cheerful, etc. The mood of a particular person in the midst of a large group can immediately be identified via very subtle changes in facial expressions. Facial expressions being very complex as well as important nonverbal communication channel are tricky to synthesize realistically using computer graphics. Computer synthesis of practical facial expressions must deal with the geometric representation of the human face and the control of the facial animation. We developed a new approach by integrating blend shape interpolation (BSI) and facial action coding system (FACS) to create a realistic and expressive computer facial animation design. The BSI is used to generate the natural face while the FACS is employed to reflect the exact facial muscle movements for four basic natural emotional expressions such as angry, happy, sad and fear with high fidelity. The results in perceiving the realistic facial expression for virtual human emotions based on facial skin color and texture may contribute towards the development of virtual reality and game environment of computer aided graphics animation systems.
Fac-Back-OPAC: An Open Source Interface to Your Library System
ERIC Educational Resources Information Center
Beccaria, Mike; Scott, Dan
2007-01-01
The new Fac-Back-OPAC (a faceted backup OPAC) is built on code that was originally developed by Casey Durfee in February 2007. It represents the convergence of two prominent trends in library tools: the decoupling of discovery tools from the traditional integrated library system (ILS) and the use of readily available open source components to…
Automated assembly of fast-axis collimation (FAC) lenses for diode laser bar modules
NASA Astrophysics Data System (ADS)
Miesner, Jörn; Timmermann, Andre; Meinschien, Jens; Neumann, Bernhard; Wright, Steve; Tekin, Tolga; Schröder, Henning; Westphalen, Thomas; Frischkorn, Felix
2009-02-01
Laser diodes and diode laser bars are key components in high power semiconductor lasers and solid state laser systems. During manufacture, the assembly of the fast axis collimation (FAC) lens is a crucial step. The goal of our activities is to design an automated assembly system for high volume production. In this paper the results of an intermediate milestone will be reported: a demonstration system was designed, realized and tested to prove the feasibility of all of the system components and process features. The demonstration system consists of a high precision handling system, metrology for process feedback, a powerful digital image processing system and tooling for glue dispensing, UV curing and laser operation. The system components as well as their interaction with each other were tested in an experimental system in order to glean design knowledge for the fully automated assembly system. The adjustment of the FAC lens is performed by a series of predefined steps monitored by two cameras concurrently imaging the far field and the near field intensity distributions. Feedback from these cameras processed by a powerful and efficient image processing algorithm control a five axis precision motion system to optimize the fast axis collimation of the laser beam. Automated cementing of the FAC to the diode bar completes the process. The presentation will show the system concept, the algorithm of the adjustment as well as experimental results. A critical discussion of the results will close the talk.
Saita, Kenichiro; Harabuchi, Yu; Taketsugu, Tetsuya; Ishitani, Osamu; Maeda, Satoshi
2016-07-14
The mechanism of the CO ligand dissociation of fac-[Re(I)(bpy)(CO)3P(OMe)3](+) has theoretically been investigated, as the dominant process of the photochemical ligand substitution (PLS) reactions of fac-[Re(I)(bpy)(CO)3PR3](+), by using the (TD-)DFT method. The PLS reactivity can be determined by the topology of the T1 potential energy surface because the photoexcited complex is able to decay into the T1 state by internal conversions (through conical intersections) and intersystem crossings (via crossing seams) with sufficiently low energy barriers. The T1 state has a character of the metal-to-ligand charge-transfer ((3)MLCT) around the Franck-Condon region, and it changes to the metal-centered ((3)MC) state as the Re-CO bond is elongated and bent. The equatorial CO ligand has a much higher energy barrier to leave than that of the axial CO, so that the axial CO ligand selectively dissociates in the PLS reaction. The single-component artificial force induced reaction (SC-AFIR) search reveals the CO dissociation pathway in photostable fac-[Re(I)(bpy)(CO)3Cl]; however, the dissociation barrier on the T1 state is substantially higher than that in fac-[Re(I)(bpy)(CO)3PR3](+) and the minimum-energy seams of crossings (MESXs) are located before and below the barrier. The MESXs have also been searched in fac-[Re(I)(bpy)(CO)3PR3](+) and no MESXs were found before and below the barrier.
The "Jugendliteratur" Web Site: Current Status and Future Directions.
ERIC Educational Resources Information Center
Green, Anne
2001-01-01
Discusses the successful use of the Web as a medium for distribution for childrens and youth literature and to suggest ways to expand and enhance the following site: ml.hss.edu/fac/Pages/amgreen/projects/jug.html. (VWL)
NASA Astrophysics Data System (ADS)
Adhikari, Binod; Dahal, Subodh; Chapagain, Narayan P.
2017-05-01
A dominant process by which energy and momentum are transported from the magnetosphere to the ionosphere is known as field-aligned current (FAC). It is enhanced during magnetic reconnection and explosive energy release at a substorm. In this paper, we studied FAC, interplanetary electric field component (Ey), interplanetary magnetic field component (Bz), and northward (x) and eastward (y) components of geomagnetic field during three events of supersubstorm occurred on 24 November 2001, 21 January 2005, and 24 August 2005. Large-scale FAC, supposed to be produced during supersubstorm (SSS), has potentiality to cause blackout on Earth. We examined temporal variations of the x and y components of high-latitude geomagnetic field during SSS, which is attributed to the FACs. We shall report the characteristics of high-latitude northward and eastward components of geomagnetic field variation during the growth phase of SSS by the implementation of discrete wavelet transform (DWT) and cross-correlation analysis. Among three examples of SSS events, the highest peak value of FAC was estimated to be 19 μAm-2. This is shore up with the prediction made by Parks (1991) and Stasiewicz et al. (1998) that the FACs may vary from a few tens to several hundred μAm-2. Although this peak value of FACs for SSS event is much higher than the average FACs associated with regular substorms or magnetic storms, it is expedient and can be expect for SSS events which might be due to very high density solar wind plasma parcels (PPs) triggering the SSS events. In all events, during growth phase, the FAC increases to extremely high level and the geomagnetic northward component decreases to extremely low level. This represents a strong positive correlation between FAC and geomagnetic northward component. The DWT analysis accounts that the highest amplitude of the wavelet coefficients indicates singularities present in FAC during SSS event. But the amplitude of squared wavelet coefficient is found
NASA Technical Reports Server (NTRS)
Madzsar, George C. (Inventor)
1993-01-01
The elemental composition of a material exposed to hot gases and subjected to wear is determined. Atoms of an elemental species not appearing in this material are implanted in a surface at a depth based on the maximum allowable wear. The exhaust gases are spectroscopically monitored to determine the exposure of these atoms when the maximum allowable wear is reached.
2015-01-01
The copper(I)-catalyzed azide–alkyne cycloaddition (CuAAC) click reaction was used to incorporate alkyne-functionalized dipicolylamine (DPA) ligands (1 and 3) for fac-[MI(CO)3]+ (M = Re/99mTc) complexation into an α-melanocyte stimulating hormone (α-MSH) peptide analogue. A novel DPA ligand with carboxylate substitutions on the pyridyl rings (3) was designed to increase the hydrophilicity and to decrease in vivo hepatobiliary retention of fac-[99mTcI(CO)3]+ complexes used in single photon emission computed tomography (SPECT) imaging studies with targeting biomolecules. The fac-[ReI(CO)3(3)] complex (4) was used for chemical characterization and X-ray crystal analysis prior to radiolabeling studies between 3 and fac-[99mTcI(OH2)3(CO)3]+. The corresponding 99mTc complex (4a) was obtained in high radiochemical yields, was stable in vitro for 24 h during amino acid challenge and serum stability assays, and showed increased hydrophilicity by log P analysis compared to an analogous complex with nonfunctionalized pyridine rings (2a). An α-MSH peptide functionalized with an azide was labeled with fac-[MI(CO)3]+ using both click, then chelate (CuAAC reaction with 1 or 3 followed by metal complexation) and chelate, then click (metal complexation of 1 and 3 followed by CuAAC with the peptide) strategies to assess the effects of CuAAC conditions on fac-[MI(CO)3]+ complexation within a peptide framework. The peptides from the click, then chelate strategy had different HPLC tR’s and in vitro stabilities compared to those from the chelate, then click strategy, suggesting nonspecific coordination of fac-[MI(CO)3]+ using this synthetic route. The fac-[MI(CO)3]+-complexed peptides from the chelate, then click strategy showed >90% stability during in vitro challenge conditions for 6 h, demonstrated high affinity and specificity for the melanocortin 1 receptor (MC1R) in IC50 analyses, and led to moderately high uptake in B16F10 melanoma cells. Log P analysis of the 99m
Dental wear quantity and direction in Chalcolithic and Medieval populations from southwest France.
Grimoud, Anne-Marie; Gibbon, Victoria E
2017-01-01
The aim of this study was to verify if dental wear changed due to the dietary shift between the Chalcolithic and Middle Ages from relatively hard and fibrous foods to soft cooked cereals. This was accomplished by comparing dental wear quantity and direction between people from two archaeological sites, Les Treilles during the Chalcolithic (mixed subsistence farmers) and Marsan from the Middle Ages (agriculturalists) in southwest France. The materials studied include 65 mandibles, 32 from Les Treilles and 33 from Marsan; 549 teeth were studied. The results show statistically significant difference in wear quantity and direction, the Chalcolithic population (Les Treilles) had the greatest levels of wear in a mainly oblique direction, with the anterior teeth heavily affected by wear. Comparatively, the Medieval sample (Marsan) had lesser levels of wear in a mainly horizontal direction, and the most heavily worn teeth were the molars and incisors. The quantity of wear seems to correlate well with changes in diet, the high level of wear on the anterior teeth in the Chalcolithic sample corresponds with the consumption of a mixed diet of fibrous and tough foods. At Marsan, the lower wear quantity was likely due to a diet of soft boiled cereals, requiring less mastication. However, wear direction appears dependent on several factors and may correlate with more mixed subsistence practices. This study demonstrates the need for additional research into the complex actions of mastication and its effect on dental wear, as well as standardised methodology for the examination of dental wear in archaeological samples. Copyright © 2016 Elsevier GmbH. All rights reserved.
Meyer, Jan-Philip; Probst, Katrin C; Trist, Iuni M L; McGuigan, Christopher; Westwell, Andrew D
2014-09-01
(18) F-FAC (1-(2'-deoxy-2'-[(18) F]fluoro-β-D-arabinofuranosyl)-cytosine) is an important 2'-fluoro-nucleoside-based positron emission tomography (PET) tracer that has been used for in vivo prediction of response to the widely used cancer chemotherapy drug gemcitabine. Previously reported synthetic routes to (18) F-FAC have relied on early introduction of the (18) F radiolabel prior to attachment to protected cytosine base. Considering the (18) F radiochemical half-life (110 min) and the technical challenges of multi-step syntheses on PET radiochemistry modular systems, late-stage radiofluorination is preferred for reproducible and reliable radiosynthesis with in vivo applications. Herein, we report the first late-stage radiosynthesis of (18) F-FAC. Cytidine derivatives with leaving groups at the 2'-position are particularly prone to undergo anhydro side-product formation upon heating because of their electron density at the 2-carbonyl pyrimidone oxygen. Our rationally developed fluorination precursor showed an improved reactivity-to-stability ratio at elevated temperatures. (18) F-FAC was obtained in radiochemical yields of 4.3-5.5% (n = 8, decay-corrected from end of bombardment), with purities ≥98% and specific activities ≥63 GBq/µmol. The synthesis time was 168 min. Copyright © 2014 John Wiley & Sons, Ltd.
Fareed, Muhammad A.; Stamboulis, Artemis
2017-01-01
Glass ionomer cement (GIC) represents a major transformation in restorative dentistry. Wear of dental restoratives is a common phenomenon and the determination of the wear resistance of direct-restorative materials is a challenging task. The aim of this paper was to evaluate the wear resistance of novel glass ionomer cement by two wear-test methods and to compare the two wear methods.The wear resistance of a conventional glass ionomer cement (HiFi Advanced Health Care Kent, UK) and cements modified by including various percentages of nanoclays (1, 2 and 4 wt %) was measured by a reciprocating wear test (ball-on-flat) and Oregon Health and Sciences University’s (OHSU) wear simulator. The OHSU wear simulation subjected the cement specimens to three wear mechanisms, namely abrasion, three-body abrasion and attrition using a steatite antagonist. The abrasion wear resulted in material loss from GIC specimen as the steatite antagonist forced through the exposed glass particles when it travelled along the sliding path.The hardness of specimens was measured by the Vickers hardness test. The results of reciprocation wear test showed that HiFi-1 resulted in the lowest wear volume 4.90 (0.60) mm3 (p < 0.05), but there was no significant difference (p > 0.05) in the wear volume in comparison to HiFi, HiFi-2 and HiFi-4. Similarly, the results of OHSU wear simulator showed that the total wear volume of HiFi-4 1.49 (0.24) was higher than HiFi-1 and HiFi-2. However, no significant difference (p > 0.05) was found in the OHSU total wear volume in GICs after nanoclay incorporation. The Vickers hardness (HV) of the nanoclay-reinforced cements was measured between 62 and 89 HV. Nanoclay addition at a higher concentration (4%) resulted in higher wear volume and wear depth. The total wear volumes were less dependent upon abrasion volume and attrition volume. The total wear depths were strongly influenced by attrition depth and to some extent by abrasion depth. The addition of nanoclay
In vitro wear rates of materials under different loads and varying pH.
Shabanian, Mitra; Richards, Lindsay C
2002-06-01
Despite the need for information about the wear characteristics of restorative materials, there have been few systemic studies of the factors that influence the rate of material wear. This study compared the wear rates of enamel and 3 tooth-colored restorative materials under different loads (0, 3.2, 6.7, and 9.95 kg) and pH levels (1.2, 3.3, and 7.0). An electromechanical tooth wear machine was used so that standard restorations representing 3 materials could be worn by opposing enamel under controlled conditions. The wear rates of enamel, composite (Z100), a conventional glass ionomer cement (Fuji IX), and a resin-modified glass ionomer cement (Fuji II LC) were compared at a range of loads (0 to 9.95 kg) and pH levels (1.2 to 7.0) and also at different sites across each restoration. Ten specimens were randomly assigned to each experimental group. Wear assessment was performed with a modified light microscope to quantify the height changes at defined points across wear facets. Four-way analysis of variance was used to compare wear rates among materials, pH levels, loads, and sites. Post-hoc t tests identified significant differences between specific pairs of experimental conditions (P<.05). The wear rates of enamel and the other test materials varied significantly with pH (P<.0001), load (P<.0001), and type of material (P<.0001). Enamel wear was influenced most by varied pH, whereas the composite was least affected by acid. The conventional glass ionomer cement was more susceptible than the composite to the effects of varied pH; the acid susceptibility of the resin-modified glass ionomer cement was generally between that of the composite and conventional glass ionomer cement. Enamel and the conventional glass ionomer cement were affected similarly by load. The composite was more resistant than the conventional glass ionomer cement to wear at higher loads; the resin-modified glass ionomer cement exhibited intermediate load resistance. Within the limitations of this
Russell, James; Pillarsetty, Nagavarakishore; Kramer, Robin M; Romesser, Paul B; Desai, Pooja; Haimovitz-Friedman, Adriana; Lowery, Maeve A; Humm, John L
2017-12-01
Although gemcitabine is a mainstay of pancreatic cancer therapy, it is only moderately effective, and it would be desirable to measure drug uptake in patients. 1-(2'-deoxy-2'-fluoroarabinofuranosyl) cytosine (FAC), is an analog of gemcitabine, and when labeled with F-18, it may be a potential surrogate PET tracer for the drug. [ 18 F]FAC was synthesized to a radiochemical purity of >96 %. The human tumor lines AsPC1, BxPC3, Capan-1, Panc1, and MiaPaca2 were grown orthotopically in nude mice. KPC mice that conditionally express oncogenic K-ras and p53 mutations in pancreatic tissue were also used. The intra-tumoral distributions of [ 14 C]gemcitabine and [ 18 F]FAC were mapped with autoradiography. The inter-tumor correlation between [ 14 C]gemcitabine and [ 18 F]FAC was established in the orthotopic tumors. Expression of the equilibrative and concentrative nucleoside transporters (ENT, CNT) in vitro was detected by western blotting. Drug uptake was characterized in vitro using [ 3 H]gemcitabine and the effect of transporter inhibition on gemcitabine and FAC uptake was investigated. The relative affinity of cells for gemcitabine and FAC was tested in competition assays. The cell lines differed in sensitivity to transport inhibitors and in competition studies. There was a good in vivo correlation between the total uptake of [ 18 F]FAC and [ 14 C]gemcitabine, measured across all orthotopic tumors. Using the KPC and BxPC3 models, we found that [ 14 C]gemcitabine and [ 18 F]FAC were largely co-localized. In the lines examined here, [ 18 F]FAC uptake correlates well with gemcitabine in vivo, supporting the notion that [ 18 F]FAC can serve as a PET radiotracer surrogate to determine the uptake and distribution of gemcitabine within pancreatic tumors.
Nechansky, A; Szolar, O H J; Siegl, P; Zinoecker, I; Halanek, N; Wiederkum, S; Kircheis, R
2009-05-01
The fully humanized Lewis-Y carbohydrate specific monoclonal antibody (mAb) IGN311 is currently tested in a passive immunotherapy approach in a clinical phase I trail and therefore regulatory requirements demand qualified assays for product analysis. To demonstrate the functionality of its Fc-region, the capacity of IGN311 to mediate complement dependent cytotoxicity (CDC) against human breast cancer cells was evaluated. The "classical" radioactive method using chromium-51 and a FACS-based assay were established and qualified according to ICH guidelines. Parameters evaluated were specificity, response function, bias, repeatability (intra-day precision), intermediate precision (operator-time different), and linearity (assay range). In the course of a fully nested design, a four-parameter logistic equation was identified as appropriate calibration model for both methods. For the radioactive assay, the bias ranged from -6.1% to -3.6%. The intermediate precision for future means of duplicate measurements revealed values from 12.5% to 15.9% and the total error (beta-expectation tolerance interval) of the method was found to be <40%. For the FACS-based assay, the bias ranged from -8.3% to 0.6% and the intermediate precision for future means of duplicate measurements revealed values from 4.2% to 8.0%. The total error of the method was found to be <25%. The presented data demonstrate that the FACS-based CDC is more accurate than the radioactive assay. Also, the elimination of radioactivity and the 'real-time' counting of apoptotic cells further justifies the implementation of this method which was subsequently applied for testing the influence of storage at 4 degrees C and 25 degrees C ('stability testing') on the potency of IGN311 drug product. The obtained results demonstrate that the qualified functional assay represents a stability indicating test method.
Clinical measurement of tooth wear: Tooth wear indices
López-Frías, Francisco J.; Castellanos-Cosano, Lizett; Martín-González, Jenifer; Llamas-Carreras, José M.
2012-01-01
Attrition, erosion, and abrasion result in alterations to the tooth and manifest as tooth wear. Each classification corresponds to a different process with specific clinical features. Classifications made so far have no accurate prevalence data because the indexes do not necessarily measure a specific etiology, or because the study populations can be diverse in age and characteristics. Tooth wears (attrition, erosion and abrasion) is perceived internationally as a growing problem. However, the interpretation and comparison of clinical and epidemiological studies, it is increasingly difficult because of differences in terminology and the large number of indicators/indices that have been developed for the diagnosis, classification and monitoring of the loss of dental hard tissue. These indices have been designed to identify increasing severity and are usually numerical, none have universal acceptance, complicating the evaluation of the true increase in prevalence reported. This article considers the ideal requirements for an erosion index. A literature review is conducted with the aim of analyzing the evolution of the indices used today and discuss whether they meet the clinical needs and research in dentistry. Key words:Tooth wear, tooth wear indices, attrition, erosion, abrasion, abfraction. PMID:24558525
mer and fac isomerism in tris chelate diimine metal complexes.
Dabb, Serin L; Fletcher, Nicholas C
2015-03-14
In this perspective, we highlight the issue of meridional (mer) and facial (fac) orientation of asymmetrical diimines in tris-chelate transition metal complexes. Diimine ligands have long been the workhorse of coordination chemistry, and whilst there are now good strategies to isolate materials where the inherent metal centered chirality is under almost complete control, and systematic methodologies to isolate heteroleptic complexes, the conceptually simple geometrical isomerism has not been widely investigated. In systems where the two donor atoms are significantly different in terms of the σ-donor and π-accepting ability, the fac isomer is likely to be the thermodynamic product. For the diimine complexes with two trigonal planar nitrogen atoms there is much more subtlety to the system, and external factors such as the solvent, lattice packing and the various steric considerations play a delicate role in determining the observed and isolable product. In this article we discuss the possibilities to control the isomeric ratio in labile systems, consider the opportunities to separate inert complexes and discuss the observed differences in their spectroscopic properties. Finally we report on the ligand orientation in supramolecular systems where facial coordination leads to simple regular structures such as helicates and tetrahedra, but the ability of the ligand system to adopt a mer orientation enables self-assembled structures of considerable beauty and complexity.
Reinders, Jörn; Sonntag, Robert; Kretzer, Jan Philippe
2014-11-01
Polyethylene wear (PE) is known to be a limiting factor in total joint replacements. However, a standardized wear test (e.g. ISO standard) can only replicate the complex in vivo loading condition in a simplified form. In this study, two different parameters were analyzed: (a) Bovine serum, as a substitute for synovial fluid, is typically replaced every 500,000 cycles. However, a continuous regeneration takes place in vivo. How does serum-replacement interval affect the wear rate of total knee replacements? (b) Patients with an artificial joint show reduced gait frequencies compared to standardized testing. What is the influence of a reduced frequency? Three knee wear tests were run: (a) reference test (ISO), (b) testing with a shortened lubricant replacement interval, (c) testing with reduced frequency. The wear behavior was determined based on gravimetric measurements and wear particle analysis. The results showed that the reduced test frequency only had a small effect on wear behavior. Testing with 1 Hz frequency is therefore a valid method for wear testing. However, testing with a shortened replacement interval nearly doubled the wear rate. Wear particle analysis revealed only small differences in wear particle size between the different tests. Wear particles were not linearly released within one replacement interval. The ISO standard should be revised to address the marked effects of lubricant replacement interval on wear rate.
Kasten, Benjamin B; Ma, Xiaowei; Liu, Hongguang; Hayes, Thomas R; Barnes, Charles L; Qi, Shibo; Cheng, Kai; Bottorff, Shalina C; Slocumb, Winston S; Wang, Jing; Cheng, Zhen; Benny, Paul D
2014-03-19
The copper(I)-catalyzed azide-alkyne cycloaddition (CuAAC) click reaction was used to incorporate alkyne-functionalized dipicolylamine (DPA) ligands (1 and 3) for fac-[M(I)(CO)3](+) (M = Re/(99m)Tc) complexation into an α-melanocyte stimulating hormone (α-MSH) peptide analogue. A novel DPA ligand with carboxylate substitutions on the pyridyl rings (3) was designed to increase the hydrophilicity and to decrease in vivo hepatobiliary retention of fac-[(99m)Tc(I)(CO)3](+) complexes used in single photon emission computed tomography (SPECT) imaging studies with targeting biomolecules. The fac-[Re(I)(CO)3(3)] complex (4) was used for chemical characterization and X-ray crystal analysis prior to radiolabeling studies between 3 and fac-[(99m)Tc(I)(OH2)3(CO)3](+). The corresponding (99m)Tc complex (4a) was obtained in high radiochemical yields, was stable in vitro for 24 h during amino acid challenge and serum stability assays, and showed increased hydrophilicity by log P analysis compared to an analogous complex with nonfunctionalized pyridine rings (2a). An α-MSH peptide functionalized with an azide was labeled with fac-[M(I)(CO)3](+) using both click, then chelate (CuAAC reaction with 1 or 3 followed by metal complexation) and chelate, then click (metal complexation of 1 and 3 followed by CuAAC with the peptide) strategies to assess the effects of CuAAC conditions on fac-[M(I)(CO)3](+) complexation within a peptide framework. The peptides from the click, then chelate strategy had different HPLC tR's and in vitro stabilities compared to those from the chelate, then click strategy, suggesting nonspecific coordination of fac-[M(I)(CO)3](+) using this synthetic route. The fac-[M(I)(CO)3](+)-complexed peptides from the chelate, then click strategy showed >90% stability during in vitro challenge conditions for 6 h, demonstrated high affinity and specificity for the melanocortin 1 receptor (MC1R) in IC50 analyses, and led to moderately high uptake in B16F10 melanoma cells
Mechanical modelling of tooth wear
Kallonen, Aki
2016-01-01
Different diets wear teeth in different ways and generate distinguishable wear and microwear patterns that have long been the basis of palaeodiet reconstructions. Little experimental research has been performed to study them together. Here, we show that an artificial mechanical masticator, a chewing machine, occluding real horse teeth in continuous simulated chewing (of 100 000 chewing cycles) is capable of replicating microscopic wear features and gross wear on teeth that resemble wear in specimens collected from nature. Simulating pure attrition (chewing without food) and four plant material diets of different abrasives content (at n = 5 tooth pairs per group), we detected differences in microscopic wear features by stereomicroscopy of the chewing surface in the number and quality of pits and scratches that were not always as expected. Using computed tomography scanning in one tooth per diet, absolute wear was quantified as the mean height change after the simulated chewing. Absolute wear increased with diet abrasiveness, originating from phytoliths and grit. In combination, our findings highlight that differences in actual dental tissue loss can occur at similar microwear patterns, cautioning against a direct transformation of microwear results into predictions about diet or tooth wear rate. PMID:27411727
Natori, Yoshiki; Kitagawa, Yasutaka; Aoki, Shogo; Teramoto, Rena; Tada, Hayato; Era, Iori; Nakano, Masayoshi
2018-03-05
The fac -Ir(ppy)₃ complex, where ppy denotes 2-phenylpyridine, is one of the well-known luminescent metal complexes having a high quantum yield. However, there have been no specific molecular design guidelines for color tuning. For example, it is still unclear how its optical properties are changed when changing substitution groups of ligands. Therefore, in this study, differences in the electronic structures and optical properties among several substituted fac -Ir(ppy)₃ derivatives are examined in detail by density functional theory (DFT) and time-dependent DFT (TD-DFT) calculations. On the basis of those results, we present rational design guidelines for absorption and emission color tuning by modifying the species of substituents and their substitution positions.
Montoya, J E; Luna, H G; Morelos, A B; Catedral, M M; Lava, A L; Amparo, J R; Cristal-Luna, G R
2013-04-01
Fluorouracil, doxorubicin, cyclophosphamide protocol (FAC) is a commonly used regimen for breast cancer due to its proven efficacy, acceptable toxicity, high affordability. While hepatic insufficiency dosing for doxorubicin and fluorouracil have been set, there is paucity of data in the literature on how to reduce doses in renal insufficiency. We sought to determine whether there is an association with pre-chemotherapy creatinine clearance, and the occurrence of clinically significant grade 3 to 5 neutropenia during the course of FAC chemotherapy. A retrospective study involving chart review from 2009 to June 2012, of breast cancer patients given FAC was conducted. Demographic profile, pre-chemotherapy complete blood count and creatinine clearance (CrCl) were recorded. Occurrence of Grade 3 to 5 neutropenia was the endpoint of the study. Descriptive statistics, one tailed t test, logistic regression analysis were done between the outcome and variables. A total of 53 patients were included in the study. The mean age of the patients was 49.77 ± 10.82 years. Patients had an ECOG performance status range of 1 to 3. Patients received mean 5.64 ± 0.92 cycles of FAC protocol chemotherapy. Pre-treatment chemotherapy WBC was 7.41 ± 2.68x109/L, Hemoglobin was 12.60 ± 1.16 g/dL, ANC 4656.89 ± 2379.32. Pre treatment CrCl was 90.79 ± 31.49 ml/min. Thirteen subjects, or 24.53% developed at least grade 3 neutropenia. Patients who developed neutropenia were significantly different from those who did not in terms of baseline WBC p=0.046 and Weight p=0.0119, CrCl p=0.032. Using logistic regression analysis, only creatinine clearance was a significant predictor of neutropenia. There was an inverse association between creatinine clearance and neutropenia, OR 0.887, 95% confidence interval (CI): 0.808- 0.973, p=0.011. The study revealed that breast cancer patients treated with FAC, there was an inverse association between creatinine clearance and occurrence of neutropenia.
The photophysics of fac-[Re(CO)3(NN)(bpa)](+) complexes: a theoretical/experimental study.
Sousa, S F; Sampaio, R N; Barbosa Neto, N M; Machado, A E H; Patrocinio, A O T
2014-08-01
The influence of the polypyridyl ligand on the photophysics of fac-[Re(CO)3(NN)(bpa)](+), bpa = 1,2-bis-(4-pyridyl)ethane and NN = 1,10-phenanthroline (phen), pyrazino[2,3-f][1,10]-phenanthroline (dpq), and dipyrido[3,2-a:2'3'-c]phenazine (dppz) has been investigated by steady state and time-resolved emission spectroscopy combined with theoretical calculations using time-dependent density functional theory (TD-DFT). The fac-[Re(CO)3(phen)(bpa)](+) is a typical MLCT emitter in acetonitrile with ϕ = 0.11 and τ = 970 ns. The emission lifetime and quantum yield decrease significantly in fac-[Re(CO)3(dpq)(bpa)](+) (ϕ = 0.05; τ = 375 ns) due to the presence of a close lying dark charge transfer state located at the pyrazine ring of dpq, as indicated by TD-DFT data. The luminescence of these complexes is quenched by hydroquinone with kq = (2.9 ± 0.1) × 10(9) and (2.6 ± 0.1) × 10(9) L mol(-1) s(-1), respectively, for NN = phen or dpq. These values are increased respectively to (4.6 ± 0.1) × 10(9) and (4.2 ± 0.1) × 10(9) L mol(-1) s(-1) in the 1 : 1 H2O-CH3CN mixture. In this medium Stern-Volmer constants determined by steady-state and time-resolved measurements differ from each other, which is indicative of static quenching, i.e. the pre-association of hydroquinone and the complexes through hydrogen bonding between the remote N-atom in the bpa ligand (KA ≅ 1-2 × 10(1) L mol(-1)), followed by a concerted proton-electron transfer. In contrast to other investigated complexes, fac-[Re(CO)3(dppz)(bpa)](+) is weakly emissive in acetonitrile at room temperature (ϕ ≅ 10(-4)) and does not exhibit a rigidochromic effect. This photophysical behaviour as well as TD-DFT data indicate that the lowest lying triplet excited state can be described as (3)ILdppz. The results provide additional insight into the influence of the polypyridyl ligand on the photophysical properties of Re(I) complexes.
Low friction wear resistant graphene films
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sumant, Anirudha V.; Berman, Diana; Erdemir, Ali
A low friction wear surface with a coefficient of friction in the superlubric regime including graphene and nanoparticles on the wear surface is provided, and methods of producing the low friction wear surface are also provided. A long lifetime wear resistant surface including graphene exposed to hydrogen is provided, including methods of increasing the lifetime of graphene containing wear surfaces by providing hydrogen to the wear surface.
NASA Astrophysics Data System (ADS)
Mohammadi, S. M.; Tavakoli-Anbaran, H.; Zeinali, H. Z.
2017-02-01
The parallel-plate free-air ionization chamber termed FAC-IR-300 was designed at the Atomic Energy Organization of Iran, AEOI. This chamber is used for low and medium X-ray dosimetry on the primary standard level. In order to evaluate the air-kerma, some correction factors such as electron-loss correction factor (ke) and photon scattering correction factor (ksc) are needed. ke factor corrects the charge loss from the collecting volume and ksc factor corrects the scattering of photons into collecting volume. In this work ke and ksc were estimated by Monte Carlo simulation. These correction factors are calculated for mono-energy photon. As a result of the simulation data, the ke and ksc values for FAC-IR-300 ionization chamber are 1.0704 and 0.9982, respectively.
USDA-ARS?s Scientific Manuscript database
Fatty acid amino acid conjugates (FACs) in regurgitant of larval Spodoptera exigua1 were initially identified as plant volatile elicitors and research has been focused on this apparent ecological disadvantage rather than on possible benefit for the caterpillar itself. Recently, we demonstrated that...
Clevenger, Kenneth D; Ye, Rosa; Bok, Jin Woo; Thomas, Paul M; Islam, Md Nurul; Miley, Galen P; Robey, Matthew T; Chen, Cynthia; Yang, KaHoua; Swyers, Michael; Wu, Edward; Gao, Peng; Wu, Chengcang C; Keller, Nancy P; Kelleher, Neil L
2018-03-20
The benzodiazepine benzomalvin A/D is a fungally derived specialized metabolite and inhibitor of the substance P receptor NK1, biosynthesized by a three-gene nonribosomal peptide synthetase cluster. Here, we utilize fungal artificial chromosomes with metabolomic scoring (FAC-MS) to perform molecular genetic pathway dissection and targeted metabolomics analysis to assign the in vivo role of each domain in the benzomalvin biosynthetic pathway. The use of FAC-MS identified the terminal cyclizing condensation domain as BenY-C T and the internal C-domains as BenZ-C 1 and BenZ-C 2 . Unexpectedly, we also uncovered evidence suggesting BenY-C T or a yet to be identified protein mediates benzodiazepine formation, representing the first reported benzodiazepine synthase enzymatic activity. This work informs understanding of what defines a fungal C T domain and shows how the FAC-MS platform can be used as a tool for in vivo analyses of specialized metabolite biosynthesis and for the discovery and dissection of new enzyme activities.
Kuo, Chien-Wei
2017-01-01
Wear particle-induced biological responses are the major factors resulting in the loosening and then failure of total joint arthroplasties. It is feasible to improve the lubrication and reduce the wear of artificial joint system. Polyetheretherketone (PEEK) is considered as a potential bearing material due to its mechanical characteristics of resistance to fatigue strain. The PEEK wear particles have been indicated to be involved in biological responses in vitro, and further studies regarding the wear phenomena and wear particle generation are needed. In this study, we have established an accelerated wear testing system with microfabricated surfaces. Various contact pressures and lubricants have been utilized in the accelerated wear tests. Our results showed that increasing contact pressure resulted in an increase of wear particle sizes and wear rate, and the size of PEEK wear particles can be controlled by the feature size of microfabricated surfaces. These results provided the information rapidly about factors that affect the morphology and amount of PEEK wear particles and can be applied in the future for application of PEEK on the biological articulation system. PMID:29230411
Su, Chen-Ying; Kuo, Chien-Wei; Fang, Hsu-Wei
2017-01-01
Wear particle-induced biological responses are the major factors resulting in the loosening and then failure of total joint arthroplasties. It is feasible to improve the lubrication and reduce the wear of artificial joint system. Polyetheretherketone (PEEK) is considered as a potential bearing material due to its mechanical characteristics of resistance to fatigue strain. The PEEK wear particles have been indicated to be involved in biological responses in vitro, and further studies regarding the wear phenomena and wear particle generation are needed. In this study, we have established an accelerated wear testing system with microfabricated surfaces. Various contact pressures and lubricants have been utilized in the accelerated wear tests. Our results showed that increasing contact pressure resulted in an increase of wear particle sizes and wear rate, and the size of PEEK wear particles can be controlled by the feature size of microfabricated surfaces. These results provided the information rapidly about factors that affect the morphology and amount of PEEK wear particles and can be applied in the future for application of PEEK on the biological articulation system.
Selection criteria for wear resistant powder coatings under extreme erosive wear conditions
NASA Astrophysics Data System (ADS)
Kulu, P.; Pihl, T.
2002-12-01
Wear-resistant thermal spray coatings for sliding wear are hard but brittle (such as carbide and oxide based coatings), which makes them useless under impact loading conditions and sensitive to fatigue. Under extreme conditions of erosive wear (impact loading, high hardness of abrasives, and high velocity of abradant particles), composite coatings ensure optimal properties of hardness and toughness. The article describes tungsten carbide-cobalt (WC-Co) systems and self-fluxing alloys, containing tungsten carbide based hardmetal particles [NiCrSiB-(WC-Co)] deposited by the detonation gun, continuous detonation spraying, and spray fusion processes. Different powder compositions and processes were studied, and the effect of the coating structure and wear parameters on the wear resistance of coatings are evaluated. The dependence of the wear resistance of sprayed and fused coatings on their hardness is discussed, and hardness criteria for coating selection are proposed. The so-called “double cemented” structure of WC-Co based hardmetal or metal matrix composite coatings, as compared with a simple cobalt matrix containing particles of WC, was found optimal. Structural criteria for coating selection are provided. To assist the end user in selecting an optimal deposition method and materials, coating selection diagrams of wear resistance versus hardness are given. This paper also discusses the cost-effectiveness of coatings in the application areas that are more sensitive to cost, and composite coatings based on recycled materials are offered.
Sliding Wear and Fretting Wear of DLC-Based, Functionally Graded Nanocomposite Coatings
NASA Technical Reports Server (NTRS)
Miyoshi, K.; Pohlchuck, B.; Street, Kenneth W.; Zabinski, J. S.; Sanders, J. H.; Voevodin, A. a.; Wu, R. L. C.
1999-01-01
Improving the tribological functionality of diamondlike carbon (DLC) films--developing, good wear resistance, low friction, and high load-carrying capacity-was the aim of this investigation. Nanocomposite coatings consisting of an amorphous DLC (a-DLC) top layer and a functionally graded titanium-titanium carbon-diamondlike carbon (Ti-Ti(sub x) C(sub y)-DLC) underlayer were produced on AISI 440C stainless steel substrates by the hybrid technique of magnetron sputtering and pulsed-laser deposition. The resultant DLC films were characterized by Raman spectroscopy, scanning electron microscopy, and surface profilometry. Two types of wear experiment were conducted in this investioation: sliding friction experiments and fretting wear experiments. Unidirectional ball-on-disk sliding friction experiments were conducted to examine the wear behavior of an a-DLC/Ti-Ti(sub x) C(sub y)-DLC-coated AISI 440C stainless steel disk in sliding contact with a 6-mm-diameter AISI 440C stainless steel ball in ultrahigh vacuum, dry nitrogen, and humid air. Although the wear rates for both the coating and ball were low in all three environments, the humid air and dry nitrogen caused mild wear with burnishing, in the a-DLC top layer, and the ultrahigh vacuum caused relatively severe wear with brittle fracture in both the a-DLC top layer and the Ti-Ti(sub x) C(sub y)-DLC underlayer. For reference, amorphous hydrogenated carbon (H-DLC) films produced on a-DLC/Ti-Ti(sub x) C(sub y)-DLC nanocomposite coatings by using an ion beam were also examined in the same manner. The H-DLC films markedly reduced friction even in ultrahigh vacuum without sacrificing wear resistance. The H-DLC films behaved much like the a-DLC/Ti-Ti(sub x) C(sub y)-DLC nanocomposite coating in dry nitrogen and humid air, presenting low friction and low wear. Fretting wear experiments were conducted in humid air (approximately 50% relative humidity) at a frequency of 80 Hz and an amplitude of 75 micron on an a
Composite Material Hazard Assessment at Crash Sites
2015-01-01
advanced composite materials. All personnel involved in rescue in close crash-site proximity are required to wear self -contained breathing apparatus...close crash-site proximity are required to wear self -contained breathing apparatus, chemical protective clothing, leather gloves, and neoprene...Take extra precaution when handling these materials. Nitrile rubber gloves can be worn underneath the leather gloves to provide chemical hazard
Dupriez, Nataliya Deyneka; von Koeckritz, Ann-Kristin; Kunzelmann, Karl-Heinz
2015-05-01
The purpose of this study is to investigate the in vitro tribological behavior of modern nonmetallic restorative materials. Specimen prepared of IPS e.max Press lithium disilicate glass ceramic, IPS Empress Esthetic leucite-reinforced glass ceramic, Everest ZS Blanks yttria-stabilized zirconia and Lava Ultimate composite were subjected to wear using a wear machine designed to simulate occlusal loads. The wear of the investigated materials and antagonists were evaluated by a three-dimensional surface scanner. The quantitative wear test results were used to compare and rank the materials. Specimens were divided into two groups with steatite and alumina antagonists. For each antagonist material an analysis of variance was applied. As a post hoc test of the significant differences, Tukey's honest significant difference test was used. With steatite antagonist: wear of zirconia < wear of leucite-reinforced ceramic < wear of lithium disilicate ceramic < wear of Lava Ultimate composite. No significant wear difference was found for steatite antagonist. The wear of IPS e.max Press and Lava Ultimate against hard alumina was found to be twice lower as compared to their wear when opposing to steatite. The differences were associated with materials mechanical properties (hardness and fracture toughness) and with materials microstructure. Wear mechanisms are discussed. © 2014 Wiley Periodicals, Inc.
Russell, James; Pillarsetty, Nagavarakishore; Kramer, Robin M; Romesser, Paul B; Desai, Pooja; Haimovitz-Friedman, Adriana; Lowery, Maeve A; Humm, John L
2017-01-01
Purpose Although gemcitabine is a mainstay of pancreatic cancer therapy, it is only moderately effective, and it would be desirable to measure drug uptake in patients. 1-(2′-deoxy-2′-fluoroarabinofuranosyl) cytosine (FAC), is an analog of gemcitabine, and when labeled with F-18, it may be a potential surrogate PET tracer for the drug. Procedures [18F]FAC was synthesized to a radiochemical purity of >96 %. The human tumor lines AsPC1, BxPC3, Capan-1, Panc1, and MiaPaca2 were grown orthotopically in nude mice. KPC mice that conditionally express oncogenic K-ras and p53 mutations in pancreatic tissue were also used. The intra-tumoral distributions of [14C]gemcitabine and [18F]FAC were mapped with autoradiography. The inter-tumor correlation between [14C]gemcitabine and [18F]FAC was established in the orthotopic tumors. Expression of the equilibrative and concentrative nucleoside transporters (ENT, CNT) in vitro was detected by western blotting. Drug uptake was characterized in vitro using [3H]gemcitabine and the effect of transporter inhibition on gemcitabine and FAC uptake was investigated. The relative affinity of cells for gemcitabine and FAC was tested in competition assays. The cell lines differed in sensitivity to transport inhibitors and in competition studies. There was a good in vivo correlation between the total uptake of [18F]FAC and [14C]gemcitabine, measured across all orthotopic tumors. Using the KPC and BxPC3 models, we found that [14C]gemcitabine and [18F]FAC were largely co-localized. Conclusions In the lines examined here, [18F]FAC uptake correlates well with gemcitabine in vivo, supporting the notion that [18F]FAC can serve as a PET radiotracer surrogate to determine the uptake and distribution of gemcitabine within pancreatic tumors. PMID:28349292
NASA Astrophysics Data System (ADS)
Korshunov, L. G.; Pushin, V. G.; Chernenko, N. L.; Makarov, V. V.
2010-07-01
Wear resistance and structural transformations upon abrasive and adhesive wear of titanium nickelide Ti49.4Ni50.6 in microcrystalline (MC) and submicrocrystalline (SMC) states have been investigated. It has been shown that the abrasive wear resistance of this alloy exceeds that of the steel 12Kh18N9 by a factor of about 2, that of the steel 110G13 (Hadfield steel), by a factor of 1.3, and is close to that of the steel 95Kh18. Upon adhesive wear in a testing-temperature range from -50 to +300°C, the Ti49.4Ni50.6 alloy, as compared to the steel 12Kh18N9, is characterized by the wear rate that is tens of times smaller and by a reduced (1.5-2.0 times) friction coefficient. The enhanced wear resistance of the Ti49.4Ni50.6 alloy is due to the development of intense strain hardening in it and to a high fracture toughness, which is a consequence of effective relaxation of high contact stresses arising in the surface layer of the alloy. The SMC state produced in the alloy with the help of equal-channel angular pressing (ECAP) has no effect on the abrasive wear resistance of the alloy. The favorable effect of ECAP on the wear resistance of the Ti49.4Ni50.6 alloy takes place under conditions of its adhesive wear at temperatures from -25 to +70°C. The electron-microscopic investigation showed that under conditions of wear at negative and room temperatures in the surface layer (1-5 μm thick) of titanium nickelide there arises a mixed structure consisting of an amorphous phase and nanocrystals of supposedly austenite and martensite. Upon friction at 200-300°C, a nanocrystalline structure of the B2 phase arises near the alloy surface, which, as is the case with the amorphous-nanocrystalline structure, is characterized by significant effective strength and wear resistance.
Evaluation of the biological response of wear debris.
Chang, Bong-Soon; Brown, Phillip Rand; Sieber, Ann; Valdevit, Antonio; Tateno, Kei; Kostuik, John Philip
2004-01-01
An animal study was conducted to evaluate the biological response to titanium particles from an artificial intervertebral disc in terms of serology and histologic changes. To determine the biological response to wear debris in the retroperitoneal and epidural space. Few wear studies exist about mechanical artificial discs. Twenty-three New Zealand white rabbits were used for two approaches of the lumbar spine. In a retroperitoneal group (10 rabbits), lateral flank approach at the L2-L3 area was used. In an epidural group (13 rabbits), a dorsal laminotomy of L2 was performed. The wear debris was obtained from mechanical test cycling of the implantable intervertebral disc. At 4 and 12 weeks postoperatively, five or six animals from each group were killed. The tissues, including deposition site, regional lymph nodes and major organs, were evaluated with hematoxylin and eosin staining. At death all rabbits were found to be healthy. Blood results from the predeath samples were found to be consistent with the preoperative blood work values. Scar tissue was minimal with good healing. All organs were found to be normal in appearance. On histopathology sections, adverse reactions such as fibrosis, granuloma formation or necrosis were not found in any tissues. Free particles were found sparingly in all tissue sections with minimal cellular response. No remarkable difference was found according to groups or time intervals. Smaller particles were found to be engulfed in macrophages without adverse biological consequences. Titanium particles traveled from the sites of deposition but elicited no to minimal biological response.
Zhou, Shang-Ming; Hill, Rebecca A; Morgan, Kelly; Stratton, Gareth; Gravenor, Mike B; Bijlsma, Gunnar; Brophy, Sinead
2015-05-11
To classify wear and non-wear time of accelerometer data for accurately quantifying physical activity in public health or population level research. A bi-moving-window-based approach was used to combine acceleration and skin temperature data to identify wear and non-wear time events in triaxial accelerometer data that monitor physical activity. Local residents in Swansea, Wales, UK. 50 participants aged under 16 years (n=23) and over 17 years (n=27) were recruited in two phases: phase 1: design of the wear/non-wear algorithm (n=20) and phase 2: validation of the algorithm (n=30). Participants wore a triaxial accelerometer (GeneActiv) against the skin surface on the wrist (adults) or ankle (children). Participants kept a diary to record the timings of wear and non-wear and were asked to ensure that events of wear/non-wear last for a minimum of 15 min. The overall sensitivity of the proposed method was 0.94 (95% CI 0.90 to 0.98) and specificity 0.91 (95% CI 0.88 to 0.94). It performed equally well for children compared with adults, and females compared with males. Using surface skin temperature data in combination with acceleration data significantly improved the classification of wear/non-wear time when compared with methods that used acceleration data only (p<0.01). Using either accelerometer seismic information or temperature information alone is prone to considerable error. Combining both sources of data can give accurate estimates of non-wear periods thus giving better classification of sedentary behaviour. This method can be used in population studies of physical activity in free-living environments. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Zhou, Shang-Ming; Hill, Rebecca A; Morgan, Kelly; Stratton, Gareth; Gravenor, Mike B; Bijlsma, Gunnar; Brophy, Sinead
2015-01-01
Objective To classify wear and non-wear time of accelerometer data for accurately quantifying physical activity in public health or population level research. Design A bi-moving-window-based approach was used to combine acceleration and skin temperature data to identify wear and non-wear time events in triaxial accelerometer data that monitor physical activity. Setting Local residents in Swansea, Wales, UK. Participants 50 participants aged under 16 years (n=23) and over 17 years (n=27) were recruited in two phases: phase 1: design of the wear/non-wear algorithm (n=20) and phase 2: validation of the algorithm (n=30). Methods Participants wore a triaxial accelerometer (GeneActiv) against the skin surface on the wrist (adults) or ankle (children). Participants kept a diary to record the timings of wear and non-wear and were asked to ensure that events of wear/non-wear last for a minimum of 15 min. Results The overall sensitivity of the proposed method was 0.94 (95% CI 0.90 to 0.98) and specificity 0.91 (95% CI 0.88 to 0.94). It performed equally well for children compared with adults, and females compared with males. Using surface skin temperature data in combination with acceleration data significantly improved the classification of wear/non-wear time when compared with methods that used acceleration data only (p<0.01). Conclusions Using either accelerometer seismic information or temperature information alone is prone to considerable error. Combining both sources of data can give accurate estimates of non-wear periods thus giving better classification of sedentary behaviour. This method can be used in population studies of physical activity in free-living environments. PMID:25968000
Ligand functionalization as a deactivation pathway in a fac-Ir(ppy)3-mediated radical addition.
Devery Iii, James J; Douglas, James J; Nguyen, John D; Cole, Kevin P; Flowers Ii, Robert A; Stephenson, Corey R J
2015-01-01
Knowledge of the kinetic behavior of catalysts under synthetically relevant conditions is vital for the efficient use of compounds that mediate important transformations regardless of their composition or driving force. In particular, these data are of great importance to add perspective to the growing number of applications of photoactive transition metal complexes. Here we present kinetic, synthetic, and spectroscopic evidence of the mechanistic behavior of fac -Ir(ppy) 3 in a visible light-mediated radical addition to 3-methylindole, demonstrating the instability of fac -Ir(ppy) 3 under these conditions. During the reaction, rapid in situ functionalization of the photocatalyst occurs, eventually leading to deactivation. These findings demonstrate a conceivable deactivation process for catalytic single electron reactions in the presence of radicophilic ligands. Attempts to inhibit photocatalyst deactivation through structural modification provide further insight into catalyst selection for a given system of interest.
Spradley, Jackson P; Glander, Kenneth E; Kay, Richard F
2016-02-01
Two factors have been considered important contributors to tooth wear: dietary abrasives in plant foods themselves and mineral particles adhering to ingested food. Each factor limits the functional life of teeth. Cross-population studies of wear rates in a single species living in different habitats may point to the relative contributions of each factor. We examine macroscopic dental wear in populations of Alouatta palliata (Gray, 1849) from Costa Rica (115 specimens), Panama (19), and Nicaragua (56). The sites differ in mean annual precipitation, with the Panamanian sites receiving more than twice the precipitation of those in Costa Rica or Nicaragua (∼3,500 mm vs. ∼1,500 mm). Additionally, many of the Nicaraguan specimens were collected downwind of active plinian volcanoes. Molar wear is expressed as the ratio of exposed dentin area to tooth area; premolar wear was scored using a ranking system. Despite substantial variation in environmental variables and the added presence of ash in some environments, molar wear rates do not differ significantly among the populations. Premolar wear, however, is greater in individuals collected downwind from active volcanoes compared with those living in environments that did not experience ash-fall. Volcanic ash seems to be an important contributor to anterior tooth wear but less so in molar wear. That wear is not found uniformly across the tooth row may be related to malformation in the premolars due to fluorosis. A surge of fluoride accompanying the volcanic ash may differentially affect the premolars as the molars fully mineralize early in the life of Alouatta. © 2015 Wiley Periodicals, Inc.
Christoforou, Anna Maria; Marzilli, Patricia A; Fronczek, Frank R; Marzilli, Luigi G
2007-12-24
Polyamine ligands (L) have excellent binding characteristics for the formation of fac-99mTc(CO)3-based radiopharmaceuticals. Normally, these L are elaborated so as to leave pendant groups designed to impart useful biodistribution characteristics to the fac-[99mTc(CO)3L] imaging agent. Our goal is to lay a foundation for understanding the features of the bound elaborated ligands by using the fac-[Re(CO)3L]-analogue approach with the minimal prototypical ligands, diethylenetriamine (dien) or simple dien-related derivatives. Treatment of the fac-[Re(CO)3(H2O)3]+ cation with such triamine (NNN) ligands afforded fac-[Re(CO)3L]+ complexes. Ligand variations included having a central amine thioether donor, thus allowing X-ray crystallographic and NMR spectroscopic comparisons of fac-[Re(CO)3L]+ complexes with NNN and NSN ligands. fac-[Re(CO)3L]+ complexes with two terminal exo-NH groups exhibit unusually far upfield exo-NH NMR signals in DMSO-d6. Upon the addition of Cl-, these exo-NH signals move downfield, while the signals of any endo-NH or central NH groups move very little. This behavior is attributed to the formation of 1:1 ion pairs having selective Cl- hydrogen bonding to both exo-NH groups. Base addition to a DMSO-d6 solution of meso-exo-[Re(CO)3(N,N',N''-Me3dien)]PF6 led to isomerization of only one NHMe group, producing the chiral isomer. The meso isomer did not form. The [Re(CO)3(N,N,N',N'',N''-pentamethyldiethylenetriamine)]triflate.[Re(CO)3(mu3-OH)]4.3.35H2O crystal, the first structure with a fac-[Re(CO)3L] complex cocrystallized with this well-known cluster, provided parameters for a bulky NNN ligand and also reveals CO-CO interlocking intermolecular interactions that could stabilize the crystal.
[Wear behavior of enamel and veneering ceramics].
Gao, Qing-ping; Chao, Yong-lie; Jian, Xin-chun; Guo, Feng; Meng, Yu-kun
2007-10-01
To compare the wear between the enamel and two types of dental decoration porcelains for all-ceramic restorations (Vita-alpha, Vintage AL). Friction coefficients, wear scar width, element concentrations and wear surface evolution were considered relatively to the tribology of that in vivo situation. The wear scars of the samples were characterized by means of dynamic atomic force microscopy (DFM). The different element concentrations of the surface before/after the wear test were determined with energy dispersion spectrometry (EDS). The friction coefficient varied from time in each kind of material. The statistical differences between materials were observed in wear scar width and properties of materials (P<0.05). DFM results showed wear surface of natural tooth full of abrasive particles and denaturation of dental texture. Wear surface of veneering ceramics consisted mainly of abrasive particles, plough and microcracking. EDS results showed that the element concentration of Fe was obviously found on the samples after wear. The main underlying mechanisms of natural teeth wear are abrasive, and denaturation of dental texture. Abrasive wear, adhesion and fatigue of veneering ceramics characterize the wear patterns which plays different role in Vita-alpha and Vintage AL. The wear patterns of veneering ceramics can be described as mild wear.
Cost effectiveness of tac versus fac in adjuvant treatment of node-positive breast cancer
Mittmann, N.; Verma, S.; Koo, M.; Alloul, K.; Trudeau, M.
2010-01-01
Background This economic analysis aimed to determine, from the perspective of a Canadian provincial government payer, the cost-effectiveness of docetaxel (Taxotere: Sanofi–Aventis, Laval, QC) in combination with doxorubicin and cyclophosphamide (tac) compared with 5-fluorouracil, doxorubicin, and cyclophosphamide (fac) following primary surgery for breast cancer in women with operable, axillary lymph node–positive breast cancer. Methods A Markov model looking at two time phases—5-year treatment and long-term follow-up—was constructed. Clinical events included clinical response (based on disease-free survival and overall survival) and rates of febrile neutropenia, stomatitis, diarrhea, and infections. Health states were “no recurrence,” “locoregional recurrence,” “distant recurrence,” and “death.” Costs were based on published sources and are presented in 2006 Canadian dollars. Model inputs included chemotherapy drug acquisition costs, chemotherapy administration costs, relapse and follow-up costs, costs for management of adverse events, and costs for granulocyte colony-stimulating factor (g-csf) prophylaxis. A 5% discount rate was applied to costs and outcomes alike. Health utilities were obtained from published sources. Results For tac as compared with fac, the incremental cost was $6921 per life-year (ly) gained and $6,848 per quality-adjusted life-year (qaly) gained. The model was robust to changes in input variables (for example, febrile neutropenia rate, utility). When g-csf and antibiotics were given prophylactically before every cycle, the incremental ratios increased to $13,183 and $13,044 respectively. Conclusions Compared with fac, tac offered improved response at a higher cost. The cost-effectiveness ratios were low, indicating good economic value in the adjuvant setting of node-positive breast cancer patients. PMID:20179798
A comparison of locally adaptive multigrid methods: LDC, FAC and FIC
NASA Technical Reports Server (NTRS)
Khadra, Khodor; Angot, Philippe; Caltagirone, Jean-Paul
1993-01-01
This study is devoted to a comparative analysis of three 'Adaptive ZOOM' (ZOom Overlapping Multi-level) methods based on similar concepts of hierarchical multigrid local refinement: LDC (Local Defect Correction), FAC (Fast Adaptive Composite), and FIC (Flux Interface Correction)--which we proposed recently. These methods are tested on two examples of a bidimensional elliptic problem. We compare, for V-cycle procedures, the asymptotic evolution of the global error evaluated by discrete norms, the corresponding local errors, and the convergence rates of these algorithms.
Mobile-bearing knees reduce rotational asymmetric wear.
Ho, Fang-Yuan; Ma, Hon-Ming; Liau, Jiann-Jong; Yeh, Chuan-Ren; Huang, Chun-Hsiung
2007-09-01
Polyethylene wear of bearing components is the most common long-term complication in total knee arthroplasty. One would anticipate differing kinematics would generate different wear patterns (including wear type, degree, and symmetry) on the articulating surface of mobile-bearing and fixed-bearing inserts. Because mobile-bearing designs facilitate movement of the insert relative to the tray when the knee rotates, we hypothesized mobile-bearing designs would reduce the incidence of rotational asymmetric wear. We examined 51 worn tibial inserts, including 15 from mobile-bearing rotating-platform posterior-cruciate-sacrificing dished prostheses and 36 from fixed-bearing posterior-cruciate-retaining flat prostheses, which were retrieved at revision surgery with an average implantation time of 115 months. We divided wear types into low-grade wear (burnishing, abrasion, and cold flow) and high-grade wear (scratching, pitting, metal embedding, and delamination) to assess wear degree of polyethylene. To assess symmetry of wear, the insert surface was divided into medial and lateral sides and each side was further divided into three equal zones along the anteroposterior direction. Low-grade wear was more common in mobile-bearing knees, whereas high-grade wear was more common in fixed-bearing knees. We identified no internal/external rotational asymmetric wear or anteroposterior asymmetric wear in mobile-bearing knees.
Bian, Yan-Yan; Zhou, Lei; Zhou, Gang; Jin, Zhong-Min; Xin, Shi-Xuan; Hua, Zi-Kai; Weng, Xi-Sheng
2018-06-01
Ultra-low-wear polyethylene (ULWPE) is a new type polyethylene made by experts who are from China petrochemical research institute, which is easy to process and implant. Preliminary test showed it was more resistant to wear than that of Ultra-high-molecular weight polyethylene (UHMWPE). The purpose of the research is to study biocompatibility, bio-tribological properties and debris characterization of ULWPE. Cytotoxicity test, hemolysis test, acute/chronic toxicity and muscular implantation test were conducted according to national standard GB/T-16886/ISO-10993 for evaluation requirements of medical surgical implants. We obtained that this novel material had good biocompatibility and biological safety. The wear performance of ULWPE and UHMWPE was evaluated in a pin-on-disc (POD) wear tester within two million cycles and a knee wear simulator within six million cycles. We found that the ULWPE was higher abrasion resistance than the UHMWPE, the wear rate of ULWPE by POD test and knee wear simulator was 0.4 mg/10 6 cycles and (16.9 ± 1.8)mg/10 6 cycles respectively, while that of UHMWPE was 1.8 mg/10 6 cycles and (24.6 ± 2.4)mg/10 6 cycles. The morphology of wear debris is also an important factor to evaluate artificial joint materials, this study showed that the ULWPE wear debris gotten from the simulator had various different shapes, including spherical, block, tear, etc. The morphology of worn surface and wear debris analysis showed that wear mechanisms of ULWPE were adhesion wear, abrasive wear and fatigue wear and other wear forms, which were consistent with that of UHMWPE. Thus we conclude that ULWPE is expected to be a lifetime implantation of artificial joint. Copyright © 2018 Elsevier Ltd. All rights reserved.
7 CFR 1945.18 - United States Department of Agriculture (USDA) Food and Agriculture Council (FAC).
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 13 2010-01-01 2009-01-01 true United States Department of Agriculture (USDA) Food and Agriculture Council (FAC). 1945.18 Section 1945.18 Agriculture Regulations of the Department of Agriculture (Continued) RURAL HOUSING SERVICE, RURAL BUSINESS-COOPERATIVE SERVICE, RURAL UTILITIES SERVICE...
7 CFR 1945.18 - United States Department of Agriculture (USDA) Food and Agriculture Council (FAC).
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 13 2011-01-01 2009-01-01 true United States Department of Agriculture (USDA) Food and Agriculture Council (FAC). 1945.18 Section 1945.18 Agriculture Regulations of the Department of Agriculture (Continued) RURAL HOUSING SERVICE, RURAL BUSINESS-COOPERATIVE SERVICE, RURAL UTILITIES SERVICE...
7 CFR 1945.18 - United States Department of Agriculture (USDA) Food and Agriculture Council (FAC).
Code of Federal Regulations, 2012 CFR
2012-01-01
... 7 Agriculture 13 2012-01-01 2012-01-01 false United States Department of Agriculture (USDA) Food and Agriculture Council (FAC). 1945.18 Section 1945.18 Agriculture Regulations of the Department of Agriculture (Continued) RURAL HOUSING SERVICE, RURAL BUSINESS-COOPERATIVE SERVICE, RURAL UTILITIES SERVICE...
Heintze, S D; Zellweger, G; Cavalleri, A; Ferracane, J
2006-02-01
The aim of the study was to evaluate two ceramic materials as possible substitutes for enamel using two wear simulation methods, and to compare both methods with regard to the wear results for different materials. Flat specimens (OHSU n=6, Ivoclar n=8) of one compomer and three composite materials (Dyract AP, Tetric Ceram, Z250, experimental composite) were fabricated and subjected to wear using two different wear testing methods and two pressable ceramic materials as stylus (Empress, experimental ceramic). For the OHSU method, enamel styli of the same dimensions as the ceramic stylus were fabricated additionally. Both wear testing methods differ with regard to loading force, lateral movement of stylus, stylus dimension, number of cycles, thermocycling and abrasive medium. In the OHSU method, the wear facets (mean vertical loss) were measured using a contact profilometer, while in the Ivoclar method (maximal vertical loss) a laser scanner was used for this purpose. Additionally, the vertical loss of the ceramic stylus was quantified for the Ivoclar method. The results obtained from each method were compared by ANOVA and Tukey's test (p<0.05). To compare both wear methods, the log-transformed data were used to establish relative ranks between material/stylus combinations and assessed by applying the Pearson correlation coefficient. The experimental ceramic material generated significantly less wear in Tetric Ceram and Z250 specimens compared to the Empress stylus in the Ivoclar method, whereas with the OHSU method, no difference between the two ceramic antagonists was found with regard to abrasion or attrition. The wear generated by the enamel stylus was not statistically different from that generated by the other two ceramic materials in the OHSU method. With the Ivoclar method, wear of the ceramic stylus was only statistically different when in contact with Tetric Ceram. There was a close correlation between the attrition wear of the OHSU and the wear of the
Chow, Shiao Y; Stevens, Marc Y; Åkerbladh, Linda; Bergman, Sara; Odell, Luke R
2016-06-27
A novel, mild and facile preparation of alkyl amides from unactivated alkyl iodides employing a fac-Ir(ppy)3 -catalyzed radical aminocarbonylation protocol has been developed. Using a two-chambered system, alkyl iodides, fac-Ir(ppy)3 , amines, reductants, and CO gas (released ex situ from Mo(CO)6 ), were combined and subjected to an initial radical reductive dehalogenation generating alkyl radicals, and a subsequent aminocarbonylation with amines affording a wide range of alkyl amides in moderate to excellent yields. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Water-stable fac-{TcO₃}⁺ complexes - a new field of technetium chemistry.
Braband, Henrik
2011-01-01
The development of technetium chemistry has been lagging behind that of its heavier congener rhenium, primarily because the inherent radioactivity of all Tc isotopes has limited the number of laboratories that can study the chemistry of this fascinating element. Although technetium is an artificial element, it is not rare. Significant amounts of the isotope (99)Tc are produced every day as a fission byproduct in nuclear power plants. Therefore, a fundamental understanding of the chemistry of (99)Tc is essential to avoid its release into the environment. In this article the chemistry of technetium at its highest oxidation state (+VII) is reviewed with a special focus on recent developments which make water-stable complexes of the general type [TcO(3)(tacn-R)](+) (tacn-R = 1,4,7-triazacyclononane or derivatives) accessible. Complexes containing the fac-{TcO(3)}(+) core display a unique reactivity. In analogy to [OsO(4)] and [RuO(4)], complexes containing the fac-{TcO(3)}(+) core undergo with alkenes metal-mediated, vicinal cis-dihydroxylation reactions (alkene-glycol interconversion) in water via a (3+2)-cycloaddition reaction. Therefore, water-stable fac-{(99m)TcO(3)}(+) complexes pave the way for a new labeling strategy for radiopharmaceutical applications, based on (3+2)-cycloaddition reactions. This new concept for the labeling of biomolecules with small [(99m)TcO(3)(tacn-R)](+)-type complexes by way of a (3+2)-cycloaddition with alkenes is discussed in detail. The herein reported developments in high-valent technetium chemistry create a new field of research with this artificial element. This demonstrates the potential of fundamental research to provide new impetus of innovation for the development of new methods for radiopharmaceutical applications.
Wear-caused deflection evolution of a slide rail, considering linear and non-linear wear models
NASA Astrophysics Data System (ADS)
Kim, Dongwook; Quagliato, Luca; Park, Donghwi; Murugesan, Mohanraj; Kim, Naksoo; Hong, Seokmoo
2017-05-01
The research presented in this paper details an experimental-numerical approach for the quantitative correlation between wear and end-point deflection in a slide rail. Focusing the attention on slide rail utilized in white-goods applications, the aim is to evaluate the number of cycles the slide rail can operate, under different load conditions, before it should be replaced due to unacceptable end-point deflection. In this paper, two formulations are utilized to describe the wear: Archard model for the linear wear and Lemaitre damage model for the nonlinear wear. The linear wear gradually reduces the surface of the slide rail whereas the nonlinear one accounts for the surface element deletion (i.e. due to pitting). To determine the constants to use in the wear models, simple tension test and sliding wear test, by utilizing a designed and developed experiment machine, have been carried out. A full slide rail model simulation has been implemented in ABAQUS including both linear and non-linear wear models and the results have been compared with those of the real rails under different load condition, provided by the rail manufacturer. The comparison between numerically estimated and real rail results proved the reliability of the developed numerical model, limiting the error in a ±10% range. The proposed approach allows predicting the displacement vs cycle curves, parametrized for different loads and, based on a chosen failure criterion, to predict the lifetime of the rail.
Interplay of Zero-Field Splitting and Excited State Geometry Relaxation in fac-Ir(ppy)3.
Gonzalez-Vazquez, José P; Burn, Paul L; Powell, Benjamin J
2015-11-02
The lowest energy triplet state, T1, of organometallic complexes based on iridium(III) is of fundamental interest, as the behavior of molecules in this state determines the suitability of the complex for use in many applications, e.g., organic light-emitting diodes. Previous characterization of T1 in fac-Ir(ppy)3 suggests that the trigonal symmetry of the complex is weakly broken in the excited state. Here we report relativistic time dependent density functional calculations of the zero-field splitting (ZFS) of fac-Ir(ppy)3 in the ground state (S0) and lowest energy triplet (T1) geometries and at intermediate geometries. We show that the energy scale of the geometry relaxation in the T1 state is large compared to the ZFS. Thus, the natural analysis of the ZFS and the radiative decay rates, based on the assumption that the structural distortion is a small perturbation, fails dramatically. In contrast, our calculations of these quantities are in good agreement with experiment.
A new methodology for predictive tool wear
NASA Astrophysics Data System (ADS)
Kim, Won-Sik
An empirical approach to tool wear, which requires a series of machining tests for each combination of insert and work material, has been a standard practice for industries since early part of the twentieth century. With many varieties of inserts and work materials available for machining, the empirical approach is too experiment-intensive that the demand for the development of a model-based approach is increasing. With a model-based approach, the developed wear equation can be extended without additional machining experiments. The main idea is that the temperatures on the primary wear areas are increasing such that the physical properties of the tool material degrade substantially and consequently tool wear increases. Dissolution and abrasion are identified to be the main mechanisms for tool wear. Flank wear is predominantly a phenomenon of abrasion as evident by the presence of a scoring mark on the flank surface. Based on this statement, it is reasonable to expect that the flank-wear rate would increase with the content of hard inclusions. However, experimental flank wear results did not necessary correspond to the content of cementite phase present in the steels. Hence, other phenomena are believed to significantly affect wear behavior under certain conditions. When the cutting temperature in the flank interface is subjected to high enough temperatures, pearlitic structure austenizes. During the formation of a new austenitic phase, the existing carbon is dissolved into the ferrite matrix, which will reduce the abrasive action. To verify the austenitic transformation, turning tests were conducted with plain carbon steels. The machined surface areas are imaged using X-ray diffraction the Scanning Electron Microscope (SEM) and the Transmission Electron Microscope (TEM). On the other hand, crater wear occurs as a result of dissolution wear and abrasive wear. To verify the wear mechanisms of crater wear, various coating inserts as well as uncoated inserts were
Re-Casting the FAC Net: People, Platforms, and Policy in Forward Air Control
2015-06-01
100 Super Sabre “Misty FAC”. . . . . . . . . . . . . . . . . . . . . . . . . 58 1 i Introduction Through the first six months of Operation...threat was greatly increased, FACs used F-100 Super Sabres and F-4 Phantom IIs to improve chances of survival. Finally, the enemy continued to...visibility. Source: http://www.pacificaviationmuseum.org/pearl-harbor-blog/north- american-f-100f-super- sabre -s-n-58-1232 Other innovations
Re-casting the FAC Net: People, Platforms, and Policy in Forward Air Control
2015-06-01
100 Super Sabre “Misty FAC”. . . . . . . . . . . . . . . . . . . . . . . . . 58 1 i Introduction Through the first six months of Operation...threat was greatly increased, FACs used F-100 Super Sabres and F-4 Phantom IIs to improve chances of survival. Finally, the enemy continued to...visibility. Source: http://www.pacificaviationmuseum.org/pearl-harbor-blog/north- american-f-100f-super- sabre -s-n-58-1232 Other innovations
Aizawa, Sen-Ichi; Tsubosaka, Soshi
2016-01-01
The optically active mixed-ligand fac(S)-tris(thiolato)rhodium(III) complexes, ΔL -fac(S)-[Rh(aet)2 (L-cys-N,S)](-) (aet = 2-aminoethanethiolate, L-cys = L-cysteinate) () and ΔLL -fac(S)-[Rh(aet)(L-cys-N,S)2 ](2-) were newly prepared by the equatorial preference of the carboxyl group in the coordinated L-cys ligand. The amide formation reaction of with 1,10-diaminodecane and polyallylamine gave the diamine-bridged dinuclear Rh(III) complex and the single-chain polymer-supported Rh(III) complex with retention of the ΔL configuration of , respectively. These Rh(III) complexes reacted with Co(III) or Co(II) to give the linear-type trinuclear structure with the S-bridged Co(III) center and the two Δ-Rh(III) terminal moieties. The polymer-supported Rh(III) complex was applied not only to the CD spectropolarimetric detection and determination of a trace of precious metal ions such as Au(III), Pt(II), and Pd(II) but also to concentration and extraction of these metal ions into the solid polymer phase. Chirality 28:85-91, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.
Students Wearing Police Uniforms Exhibit Biased Attention toward Individuals Wearing Hoodies.
Civile, Ciro; Obhi, Sukhvinder S
2017-01-01
Police provide an essential public service and they often operate in difficult circumstances, requiring high-speed cognition. Recent incidents involving apparent profiling and aggressive behavior have led to accusations that the police are sometimes biased. Given that previous research has shown a link between clothing and cognition, we investigated the question of whether the police uniform itself might induce a bias in social attention. To address this question, and using a Canadian university student sample, we assessed whether wearing a police uniform biases attention toward black faces compared to white faces, and low-status individuals compared to high-status individuals. In Experiment 1 ( n = 28), participants wore either a police-style uniform or mechanic overalls, and performed a shape categorization task in the presence of a distractor that could be either: a black face, a white face, a person wearing a hoodie (whom we propose will be associated with low SES), or a person wearing a suit (whom we propose will be associated with high SES). Participants wearing the police-style uniform exhibited biased attention, indexed by slower reaction times (RTs), in the presence of low-SES images. In Experiment 2 ( n = 28), we confirmed this bias using a modified Dot-Probe task - an alternate measure of attentional bias in which we observed faster RTs to a dot probe that was spatially aligned with a low SES image. Experiment 3 ( n = 56) demonstrated that attentional bias toward low-SES targets appears only when participants wear the police-style uniform, and not when they are simply exposed to it - by having it placed on the desk in front of them. Our results demonstrate that wearing a police-style uniform biases attention toward low-SES targets. Thus, wearing a police-style uniform may induce a kind of "status-profiling" in which individuals from low-status groups become salient and capture attention. We note that our results are limited to university students and
Students Wearing Police Uniforms Exhibit Biased Attention toward Individuals Wearing Hoodies
Civile, Ciro; Obhi, Sukhvinder S.
2017-01-01
Police provide an essential public service and they often operate in difficult circumstances, requiring high-speed cognition. Recent incidents involving apparent profiling and aggressive behavior have led to accusations that the police are sometimes biased. Given that previous research has shown a link between clothing and cognition, we investigated the question of whether the police uniform itself might induce a bias in social attention. To address this question, and using a Canadian university student sample, we assessed whether wearing a police uniform biases attention toward black faces compared to white faces, and low-status individuals compared to high-status individuals. In Experiment 1 (n = 28), participants wore either a police-style uniform or mechanic overalls, and performed a shape categorization task in the presence of a distractor that could be either: a black face, a white face, a person wearing a hoodie (whom we propose will be associated with low SES), or a person wearing a suit (whom we propose will be associated with high SES). Participants wearing the police-style uniform exhibited biased attention, indexed by slower reaction times (RTs), in the presence of low-SES images. In Experiment 2 (n = 28), we confirmed this bias using a modified Dot-Probe task – an alternate measure of attentional bias in which we observed faster RTs to a dot probe that was spatially aligned with a low SES image. Experiment 3 (n = 56) demonstrated that attentional bias toward low-SES targets appears only when participants wear the police-style uniform, and not when they are simply exposed to it – by having it placed on the desk in front of them. Our results demonstrate that wearing a police-style uniform biases attention toward low-SES targets. Thus, wearing a police-style uniform may induce a kind of “status-profiling” in which individuals from low-status groups become salient and capture attention. We note that our results are limited to university students
2017-12-08
Transthyretin (TTR) Mediated Familial Amyloidotic Cardiomyopathy (FAC); Amyloidosis, Hereditary; Amyloid Neuropathies, Familial; Amyloid Neuropathies; Amyloidosis, Hereditary, Transthyretin-Related; Familial Transthyretin Cardiac Amyloidosis
Risk Factors for Contact Lens Bacterial Contamination During Continuous Wear
Szczotka-Flynn, Loretta B.; Bajaksouzian, Saralee; Jacobs, Michael R.; Rimm, Alfred
2009-01-01
Purpose Microbial contamination of contact lenses is associated with corneal infection and inflammation. This study determined which microbiological, clinical and demographic factors are associated with bacterial contamination of a silicone hydrogel contact lens when worn for continuous wear. Methods Two hundred five normal subjects were enrolled in the Longitudinal Analysis of Silicone Hydrogel (LASH) Contact Lens Study and were fitted with lotrafilcon A lenses for monthly continuous wear and followed for 1 year. Lenses were aseptically removed after 1 week and 4 months of wear and cultured using an agar sandwich technique. Lids and conjunctiva were routinely cultured at baseline, and after 1 week and 4 months of continuous wear. Lenses and ocular sites were considered to have substantial microbial bioburden when they harbored pathogenic organisms or high levels of commensal organisms. Univariate and multivariate logistic regression analyses were conducted to examine whether substantial conjunctival or lid bioburden, subject demographics, lens wearing history, symptoms, and biomicroscopic signs were associated with lens bioburden. Results About one-third (32.4%) of subjects had substantial bacterial bioburden in either eye across multiple visits. Over half (53.2%) and about one-tenth (11.7%) of subjects had substantial lid and conjunctival bioburden, respectively, and 11.2% discontinued due to discomfort. The adjusted odds ratios (and 95% confidence intervals) for presence of substantial lens bioburden were 2.49 (1.17–5.30), 4.24 (1.45–12.40), and 4.11 (1.17–14.46) for substantial lid bioburden, substantial conjunctival bioburden, and lens discomfort, respectively. Conclusions Bacterial contamination of silicone hydrogel contact lenses is common during continuous wear. Substantial lens bioburden is associated with discomfort precluding successful continuous wear. The presence of substantial lid and conjunctival bioburden are associated with a 2.5 fold and
Effects of Load and Speed on Wear Rate of Abrasive Wear for 2014 Al Alloy
NASA Astrophysics Data System (ADS)
Odabas, D.
2018-01-01
In this paper, the effects of the normal load and sliding speed on wear rate of two-body abrasive wear for 2014 Al Alloy were investigated in detail. In order to understand the variation in wear behaviour with load and speed, wear tests were carried out at a sliding distance of 11 m, a speed of 0.36 m/s, a duration of 30 s and loads in the range 3-11 N using 220 grit abrasive paper, and at a speed range 0.09-0.90 m/s, a load of 5 N and an average sliding distance of 11 m using abrasive papers of 150 grit size under dry friction conditions. Before the wear tests, solution treatment of the 2014 Al alloy was carried out at temperatures of 505 and 520 °C for 1 h in a muffle furnace and then quenched in cold water at 15 °C. Later, the ageing treatment was carried out at 185 °C for 8 h in the furnace. Generally, wear rate due to time increased linearly and linear wear resistance decreased with increasing loads. However, the wear rate was directly proportional to the load up to a critical load of 7 N. After this load, the slope of the curves decreased because the excessive deformation of the worn surface and the instability of the abrasive grains began to increase. When the load on an abrasive grain reaches a critical value, the groove width is about 0.17 of the abrasive grain diameter, and the abrasive grains begin to fail. The wear rate due to time increased slightly as the sliding speed increased in the range 0.09-0.90 m/s. The reason for this is that changes arising from strain rate and friction heating are expected with increasing sliding speeds.
Adhesive Wear of Rollers in Vacuum
NASA Technical Reports Server (NTRS)
Shaeef, Iqbal; Krantz, Timothy L.
2012-01-01
This work was done to support NASA's James Webb Space Telescope that is equipped with a Near Infrared Camera and Spectrograph and Micro Shutter Assembly (MSA). A MSA mechanism's qualification test in cryogenic vacuum at 30deg K for 96K cycles resulted in roller wear and formation of some debris. Lab tests in vacuum were conducted at NASA Glenn Research Center (GRC) to understand the wear of Ti6Al4V mated with 440F steel rollers. Misalignment angle was found to have the most significant effect on debris formation. At misalignment angle of 1.4deg, significant amount of wear debris were formed within 50,000 cycles. Very few wear particles were found for a zero misalignment angle, and the total wear was small even after 367,000 cycles. The mode of wear in all the tests was attributed to adhesion, which was clearly evident from video records as well as the plate-like amalgamated debris material from both rollers. The adhesive wear rate was found to be approximately proportional to the misalignment angle. The wear is a two-way phenomenon, and the mixing of both roller materials in wear debris was confirmed by x-ray fluorescence (XRF) and EDX spectra. While there was a net loss of mass from the steel rollers, XRF and energy dispersive x-ray (EDX) spectra showed peaks of Ti on steel rollers, and peaks of Fe on Ti rollers. These results are useful for designers in terms of maintaining appropriate tolerances to avoid misalignment of rolling elements and the resulting severe wear
Christoforou, Anna Maria; Fronczek, Frank R; Marzilli, Patricia A; Marzilli, Luigi G
2007-08-20
To achieve a net-neutral coordination unit in radiopharmaceuticals with a fac-M(CO)3+ core (M = Tc, Re), facially coordinated monoanionic tridentate ligands are needed. New neutral fac-Re(CO)3L complexes were obtained by treating fac-[Re(CO)3(H2O)3]+ with unsymmetrical tridentate NNN donor ligands (LH) based primarily on a diethylenetriamine (dien) moiety with an aromatic group linked to a terminal nitrogen through a sulfonamide. LHs contain 2,4,6-trimethylbenzenesulfonyl (tmbSO2) and 5-(dimethylamino)naphthalene-1-sulfonyl (DNS) groups. X-ray crystallographic and NMR analyses confirm that in both the solid and the solution states all L- in fac-Re(CO)3L complexes are bound in a tridentate fashion with one donor being nitrogen from a deprotonated sulfonamido group. Another fundamental property that is important in radiopharmaceuticals is shape, which in turn depends on ring pucker. For L- = tmbSO2-dien-, tmbSO2-N'-Medien-, and tmbSO2-N,N-Me2dien-, the two chelate rings have a different pucker chirality, as is commonly found for a broad range of metal complexes. However, for fac-Re(CO)3(DNS-dien), both chelate rings have the same pucker chirality because the sulfonamido ring has an unusual pucker for the absolute configuration at Re; a finding that is attributable to intramolecular and intermolecular hydrogen bonds from the sulfonamido oxygens to the NH2 groups. Averaging of tmb NMR signals, even at -90 degrees C for Re(CO)3(tmbSO2-N,N-Me2dien), indicates rapid dynamic motion in the complexes with this group. However, examination of the structures suggests that free rotation about the S-C(tmb) bond is not possible but that concerted coupled rotations about the N-S and the S-C bonds can explain the NMR data.
Risk Assessment for Tooth Wear.
Kontaxopoulou, Isavella; Alam, Sonia
2015-08-01
Tooth wear has an increasing prevalence in the UK population. The aetiology is commonly multifactorial, and the aetiopathology is through a combination of erosion, attrition, abrasion and abfraction. Erosion is associated with intrinsic or extrinsic acids, and therefore subjects with reflux disease and eating disorders are at increased risk. Fruit juice, fruits and carbonated drink consumption, frequency of consumption and specific habits are also risk factors. Attrition is more prevalent in bruxists. Other habits need to be considered when defining the risk of tooth wear. Abrasion is usually associated with toothbrushing and toothpastes, especially in an already acidic environment. Patients with extensive lesions that affect dentin may be at higher risk, as well as those presenting with unstained lesions. Monitoring of the progress of tooth wear is recommended to identify those with active tooth wear. Indices for tooth wear are a helpful aid.
NASA Astrophysics Data System (ADS)
Que, Like
Wear is one of the major causes of artificial total knee arthroplasty (TKA) failure. Wear debris can cause adverse reactions to the surrounding tissue which can ultimately lead to loosening of the prosthesis. The wear behavior of UHMWPE tibial components have been studied extensively, but relatively little attention has been paid to the CoCrMo femoral component. The goal of the present study was to investigate the wear mechanisms of CoCrMo femoral components, to study the effect of CoCrMo alloy surface roughness on the wear of UHMWPE, and to determine the effect of heat treatments on the wear resistance of the CoCrMo implant alloys. The surface roughness of twenty-seven retrieved CoCrMo femoral components was analyzed. A multiple station wear testing machine and a wear fixture attached to an MTS 858 bionix system were built and used for in vitro wear studies of the CoCrMo/UHMWPE bearing couple. Solution and aging treatments were applied to the CoCrMo alloys. A white light interference surface profilometer (WLISP) and a scanning electron microscope (SEM) were used to measure the surface roughness and to study wear mechanisms of CoCrMo alloy. An optical microscope was used for alloy microstructure study. X-ray diffraction tests were performed to identify alloy phase transformation after aging. The micro-structure, hardness, and wear resistance of the alloys were studied. Surface roughness was used to quantify alloy wear, and the minimum number of surface roughness measurements required to obtain a reliable and repeatable characterization of surface roughness for a worn alloy surface was determined. The surfaces of the retrieved CoCrMo femoral components appeared to be damaged by metal particles embedded in the UHMWPE tibial component and metal-on-metal wear due to UHMWPE tibial component through-wear. Surface roughness of the femoral components was not correlated with patient age, weight, sex, or length of implantation. In vitro wear tests showed that when the Co
Elucidation of wear mechanisms by ferrographic analysis
NASA Technical Reports Server (NTRS)
Jones, W. R., Jr.
1981-01-01
The use of ferrographic analysis in conjunction with light and scanning electron microscopy is described for the elucidation of wear mechanisms taking place in operating equipment. Example of adhesive wear, abrasive wear, corrosive wear, rolling element fatigue, lubricant breakdown, and other wear modes are illustrated. In addition, the use of magnetic solutions to precipitate nonmagnetic debris from aqueous and nonaqueous fluids is described.
Kovochich, Michael; Fung, Ernest S; Donovan, Ellen; Unice, Kenneth M; Paustenbach, Dennis J; Finley, Brent L
2018-04-01
Advantages of second-generation metal-on-metal (MoM) hip implants include low volumetric wear rates and the release of nanosized wear particles that are chemically inert and readily cleared from local tissue. In some patients, edge loading conditions occur, which result in higher volumetric wear. The objective of this study was to characterize the size, morphology, and chemistry of wear particles released from MoM hip implants during normal (40° angle) and edge-loading (65° angle with microseparation) conditions. The mean primary particle size by volume under normal wear was 35 nm (range: 9-152 nm) compared with 95 nm (range: 6-573 nm) under edge-loading conditions. Hydrodynamic diameter analysis by volume showed that particles from normal wear were in the nano- (<100 nm) to submicron (<1000 nm) size range, whereas edge-loading conditions generated particles that ranged from <100 nm up to 3000-6000 nm in size. Particles isolated from normal wear were primarily chromium (98.5%) and round to oval in shape. Edge-loading conditions generated more elongated particles (4.5%) (aspect ratio ≥ 2.5) and more CoCr alloy particles (9.3%) compared with normal wear conditions (1.3% CoCr particles). By total mass, edge-loading particles contained approximately 640-fold more cobalt than normal wear particles. Our findings suggest that high wear conditions are a potential risk factor for adverse local tissue effects in MoM patients who experience edge loading. This study is the first to characterize both the physical and chemical characteristics of MoM wear particles collected under normal and edge-loading conditions. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 986-996, 2018. © 2017 Wiley Periodicals, Inc.
Gear Tooth Wear Detection Algorithm
NASA Technical Reports Server (NTRS)
Delgado, Irebert R.
2015-01-01
Vibration-based condition indicators continue to be developed for Health Usage Monitoring of rotorcraft gearboxes. Testing performed at NASA Glenn Research Center have shown correlations between specific condition indicators and specific types of gear wear. To speed up the detection and analysis of gear teeth, an image detection program based on the Viola-Jones algorithm was trained to automatically detect spiral bevel gear wear pitting. The detector was tested using a training set of gear wear pictures and a blind set of gear wear pictures. The detector accuracy for the training set was 75 percent while the accuracy for the blind set was 15 percent. Further improvements on the accuracy of the detector are required but preliminary results have shown its ability to automatically detect gear tooth wear. The trained detector would be used to quickly evaluate a set of gear or pinion pictures for pits, spalls, or abrasive wear. The results could then be used to correlate with vibration or oil debris data. In general, the program could be retrained to detect features of interest from pictures of a component taken over a period of time.
Liu, Ren-Shyan; Chou, Ta-Kai; Chang, Chih-Hsien; Wu, Chun-Yi; Chang, Chi-Wei; Chang, Tsui-Jung; Wang, Shih-Jen; Lin, Wuu-Jyh; Wang, Hsin-Ell
2009-04-01
2-Deoxy-2-[(18)F]fluoro-d-glucose ([(18)F]FDG), [(18)F]fluoroacetate ([(18)F]FAc) and [(18)F]fluoromisonidazole ([(18)F]FMISO) were all considered to be positron emission tomography (PET) probes for tumor diagnosis, though based on different rationale of tissue uptake. This study compared the biodistribution, pharmacokinetics and imaging of these three tracers in a sarcoma- and inflammation-bearing mouse model. C3H mice were inoculated with 2x10(5) KHT sarcoma cells in the right thigh on Day 0. Turpentine oil (0.1 ml) was injected in the left thigh on Day 11 to induce inflammatory lesion. Biodistribution, pharmacokinetics and microPET imaging of [(18)F]FMISO, [(18)F]FDG and [(18)F]FAc were performed on Day 14 after tumor inoculation. The inflammatory lesions were clearly visualized by [(18)F]FDG/microPET and autoradiography at 3 days after turpentine oil injection. The tumor-to-muscle and inflammatory lesion-to-muscle ratios derived from microPET imaging were 6.79 and 1.48 for [(18)F]FMISO, 8.12 and 4.69 for [(18)F]FDG and 3.72 and 3.19 for [(18)F]FAc at 4 h post injection, respectively. Among these, the tumor-to-inflammation ratio was the highest (4.57) for [(18)F]FMISO compared with that of [(18)F]FDG (1.73) and [(18)F]FAc (1.17), whereas [(18)F]FAc has the highest bioavailability (area under concentration of radiotracer vs. time curve, 116.2 hxpercentage of injected dose per gram of tissue). MicroPET images and biodistribution studies showed that the accumulation of [(18)F]FMISO in the tumor is significantly higher than that in inflammatory lesion at 4 h post injection. [(18)F]FDG and [(18)F]FAc delineated both tumor and inflammatory lesions. Our results demonstrated the potential of [(18)F]FMISO/PET in distinguishing tumor from inflammatory lesion.
In vitro wear of new indirect resin composites.
Jain, V; Platt, J A; Moore, B K; Borges, G A
2009-01-01
This in vitro study evaluated the toothbrush abrasion wear, three-body Alabama wear and two-body pin-on-disc wear of four commercial indirect resin composites. Enamel shades of Radica (R), Sculpture Plus (S), Belleglass-NG (B) and Gradia Indirect (G) were used. For measuring wear due to toothbrush abrasion, six specimens of each group were fabricated, then brushed in a toothbrush abrasion machine for 20,000 cycles. Material loss was determined by weighing and conversion to volume loss. Three-body wear was measured on six samples for each group using an Alabama-type wear testing machine for 400,000 cycles. Wear depth was measured with a contact profilometer. For two-body wear, five disc specimens were prepared and tested in a two-body wear-testing machine against hydroxypatite sliders for 25,000 cycles. Data were analyzed with one-way analysis of variance (ANOVA) and Tukey test (alpha=0.05). Wear was the highest in Sculpture Plus by all three methods tested and the lowest wear was observed in Belleglass-NG. No statistical difference in wear was noted from Radica.
Evaluation of galectin binding by frontal affinity chromatography (FAC).
Iwaki, Jun; Hirabayashi, Jun
2015-01-01
Frontal affinity chromatography (FAC) is a simple and versatile procedure enabling quantitative determination of diverse biological interactions in terms of dissociation constants (K d), even though these interactions are relatively weak. The method is best applied to glycans and their binding proteins, with the analytical system operating on the basis of highly reproducible isocratic elution by liquid chromatography. Its application to galectins has been successfully developed to characterize their binding specificities in detail. As a result, their minimal requirements for recognition of disaccharides, i.e., β-galactosides, as well as characteristic features of individual galectins, have been elucidated. In this chapter, we describe standard procedures to determine the K d's for interactions between a series of standard glycans and various galectins.
Critical length scale controls adhesive wear mechanisms
Aghababaei, Ramin; Warner, Derek H.; Molinari, Jean-Francois
2016-01-01
The adhesive wear process remains one of the least understood areas of mechanics. While it has long been established that adhesive wear is a direct result of contacting surface asperities, an agreed upon understanding of how contacting asperities lead to wear debris particle has remained elusive. This has restricted adhesive wear prediction to empirical models with limited transferability. Here we show that discrepant observations and predictions of two distinct adhesive wear mechanisms can be reconciled into a unified framework. Using atomistic simulations with model interatomic potentials, we reveal a transition in the asperity wear mechanism when contact junctions fall below a critical length scale. A simple analytic model is formulated to predict the transition in both the simulation results and experiments. This new understanding may help expand use of computer modelling to explore adhesive wear processes and to advance physics-based wear laws without empirical coefficients. PMID:27264270
Backside wear in modern total knee designs.
Jayabalan, Prakash; Furman, Bridgette D; Cottrell, Jocelyn M; Wright, Timothy M
2007-02-01
Although modularity affords various options to the orthopedic surgeon, these benefits come at a price. The unintended bearing surface between the back surface of the tibial insert and the metallic tray results in micromotion leading to polyethylene wear debris. The objective of this study was to examine the backside wear of tibial inserts from three modern total knee designs with very different locking mechanisms: Insall-Burstein II (IB II), Optetrak, and Advance. A random sample of 71 inserts were obtained from our institution's retrieval collection and examined to assess the extent of wear, depth of wear, and wear damage modes. Patient records were also obtained to determine patient age, body mass index, length of implantation, and reason for revision. Modes of wear damage (abrasion, burnishing, scratching, delamination, third body debris, surface deformation, and pitting) were then scored in each zone from 0 to 3 (0 = 0%, 1 = 0-10%, 2 = 10-50%, and 3 = >50%). The depth of wear was subjectively identified as removal of manufacturing identification markings stamped onto the inferior surface of the polyethylene. Both Advance and IB II polyethylene inserts showed significantly higher scores for backside wear than the Optetrak inserts. All IB II and Advance implants showed evidence of backside wear, whereas 17% (5 out of 30) of the retrieved Optetrak implants had no observable wear. There were no significant differences when comparing the depth of wear score between designs. The locking mechanism greatly affects the propensity for wear and should be considered when choosing a knee implant system.
Dressing wear time after breast reconstruction: study protocol for a randomized controlled trial
2013-01-01
Background One of the major risk variables for surgical site infection is wound management. Understanding infection risk factors for breast operations is essential in order to develop infection-prevention strategies and improve surgical outcomes. The aim of this trial is to assess the influence of dressing wear time on surgical site infection rates and skin colonization. Patients’ perception at self-assessment will also be analyzed. Methods/Design This is a two-arm randomized controlled trial. Two hundred breast cancer patients undergoing immediate or delayed breast reconstruction will be prospectively enrolled. Patients will be randomly allocated to group I (dressing removed on postoperative day one) or group II (dressing removed on postoperative day six). Surgical site infections will be defined by standard criteria from the Centers for Disease Control and Prevention (CDC). Skin colonization will be assessed by culture of samples collected at predefined time points. Patients will score dressing wear time with regard to safety, comfort and convenience. Discussion The evidence to support dressing standards for breast surgery wounds is empiric and scarce. CDC recommends protecting, with a sterile dressing for 24 to 48 hours postoperatively, a primarily closed incision, but there is no recommendation to cover this kind of incision beyond 48 hours, or on the appropriate time to shower or bathe with an uncovered incision. The results of the ongoing trial may support standard recommendations regarding dressing wear time after breast reconstruction. Trial registration ClinicalTrials.gov identifier: http://NCT01148823. PMID:23432779
Deaton, Joseph C; Young, Ralph H; Lenhard, Jerome R; Rajeswaran, Manju; Huo, Shouquan
2010-10-18
The photophysical properties of tris-cyclometalated iridium(III) complexes have been probed by chemical and geometric variation through the series fac- and mer-Ir(piq)(x)(ppy)(3-x) (x = 1-3; piq = 1-phenylisoquinolinato-N(∧)C(2'), ppy = 2-phenylpyridinato-N(∧)C(2')). The phosphorescent decays were recorded in solution at 295 K and in polymer films from 2 to 295 K. In the heteroleptic complexes, emission occurs based solely on the piq ligand(s), at least by the nanosecond time scale, as its excited states are the lowest energy. Because fac-Ir(piq)(3) and fac-Ir(ppy)(3) possess practically the same oxidation potential, comparison of photophysical properties through the series fac-Ir(piq)(x)(ppy)(3-x) (x = 1-3) revealed the effects of having one, two, or three emissive piq ligands with no confounding effects from differences in electron withdrawing or donating properties between the spectator ppy ligands and the piq ligands. Effects of placement of piq ligands in different coordination geometries were elucidated by comparisons to the mer series.
Modeling wear of cast Ti alloys.
Chan, Kwai S; Koike, Marie; Okabe, Toru
2007-05-01
The wear behavior of Ti-based alloys was analyzed by considering the elastic-plastic fracture of individual alloys in response to the relevant contact stress field. Using the contact stresses as the process driving force, wear was computed as the wear rate or volume loss as a function of hardness and tensile ductility for Ti-based cast alloys containing an alpha, alpha+beta or beta microstructure with or without the intermetallic precipitates. Model predictions indicated that wear of Ti alloys increases with increasing hardness but with decreasing fracture toughness or tensile ductility. The theoretical results are compared with experimental data to elucidate the roles of microstructure in wear and contrasted against those in grindability.
Modeling wear of cast Ti alloys
Chan, Kwai S.; Koike, Marie; Okabe, Toru
2007-01-01
The wear behavior of Ti-based alloys was analyzed by considering the elastic–plastic fracture of individual alloys in response to the relevant contact stress field. Using the contact stresses as the process driving force, wear was computed as the wear rate or volume loss as a function of hardness and tensile ductility for Ti-based cast alloys containing an α, α+β or β microstructure with or without the intermetallic precipitates. Model predictions indicated that wear of Ti alloys increases with increasing hardness but with decreasing fracture toughness or tensile ductility. The theoretical results are compared with experimental data to elucidate the roles of microstructure in wear and contrasted against those in grindability. PMID:17224314
Study on Composition, Microstructure and Wear Behavior of Fe-B-C Wear-Resistant Surfacing Alloys
NASA Astrophysics Data System (ADS)
Zhuang, Minghui; Li, Muqin; Wang, Jun; Ma, Zhen; Yuan, Shidan
2017-12-01
Fe-B-C alloy layers with various microstructures were welded on Q235 steel plates using welding powders/H08Mn2Si and welding wires composite surfacing technology. The relationship existing between the chemical composition, microstructure and wear resistance of the surfacing alloy layers was investigated by scanning electron microscopy, x-ray diffraction, electron backscatter diffraction and wear tests. The results demonstrated that the volume fractions and morphologies of the microstructures in the surfacing alloy layers could be controlled by adjusting the boron and carbon contents in the welding powders, which could further regulate the wear resistance of the surfacing alloy layers. The typical microstructures of the Fe-B-C surfacing alloy layers included dendritic Fe, rod-like Fe2B, fishbone-like Fe2B and daisy-like Fe3(C, B). The wear resistance of the alloy layers with various morphologies differed. The wear resistance order of the different microstructures was: rod-like Fe2B > fishbone-like Fe2B > daisy-like Fe3(C, B) > dendritic Fe. A large number of rod-like Fe2B with high microhardness could be obtained at the boron content of 5.70 5.90 wt.% and the carbon content of 0.50 0.60wt.%. The highest wear resistance of the Fe-B-C alloy layers reached the value of 24.1 g-1, which demonstrates the main microscopic cutting wear mechanism of the Fe-B-C alloy layers.
Clinical Biomechanics of Wear in Total Hip Arthroplasty
Callaghan, John J; Pedersen, Douglas R; Johnston, Richard C; Brown, Thomas D
2003-01-01
Complementary clinical and laboratory studies were performed to identify variables associated with polyethylene wear following total hip replacement, and to elucidate the mechanisms responsible for accelerated wear in the total hip arthroplasty construct. Observational cohort studies were performed using a prospective clinical database of more than 4000 consecutive primary total hip arthroplasties performed by a single surgeon, to identify wear-related variables. These variables included head size, acetabular/femoral component impingement, and third body debris. Novel digital edge detection techniques were developed and employed to accurately measure wear, and to determine the relationships of head size and third body debris to acceleration of wear. A novel slidingdistance-coupled finite element model was formulated and employed to examine the mechanisms responsible for wear. The long-term cohort studies demonstrated smaller head sizes to be associated with less wear. Third body debris generated from cable fretting was associated with an increase in wear, osteolysis, and acetabular loosening, especially with larger head sizes. The sliding-distance-coupled finite element model replicated the wear rates occurring in vitro and in vivo, demonstrating the importance of sliding distance on polyethylene wear following total hip arthroplasty. It also demonstrated substantial increases in wear associated with femoral head scratching from third body debris. Further extension of the finite element formulation demonstrated the potential for acetabular component rim damage from impingement wear, and the enhanced potential for third body ingress to the bearing surface with larger head sizes. Edge detection wear measurement techniques demonstrated that early wear rates were predictive of long-term wear rates. These complementary clinical and laboratory investigations have provided insight into 1) the significance of sliding distance and physiologic loci of motion as contributing
Contact lens wear is intrinsically inflammatory.
Efron, Nathan
2017-01-01
Eye-care practitioners typically associate ocular inflammation during contact lens wear with serious complications such as microbial keratitis; however, more subtle mechanisms may be at play. This paper tests the notion that contact lens wear is intrinsically inflammatory by exploring whether uncomplicated contact lens wear meets the classical, clinical definition of inflammation - rubor (redness), calor (heat), tumor (swelling), dolor (pain) and functio laesa (loss of function) - as well as the contemporary, sub-clinical definition of inflammation (cellular and biochemical reactions). It is demonstrated that all of these clinical and sub-clinical criteria are met with hydrogel lens wear and most are met with silicone hydrogel lens wear, indicating that uncomplicated contact lens wear is intrinsically inflammatory. Consideration of both traditional and contemporary thinking about the role of inflammation in the human body leads to the perhaps surprising conclusion that the chronic, low grade, sub-clinical inflammatory status of the anterior eye during contact lens wear, which may be termed 'para-inflammation', is a positive, protective phenomenon, whereby up-regulation of the immune system, in a non-damaging way, maintains the eye in a state of 'heightened alert', ready to ward off any extrinsic noxious challenge. Characterisation of this inflammatory status may lead to the development of lens engineering or pharmacological strategies to modulate contact lens-induced inflammation, so as to render lens wear more safe and comfortable. © 2016 Optometry Australia.
Wear of dental tissues and materials.
Craig, R G; Powers, J M
1976-06-01
Wear may result from physiological or pathological conditions and may be desirable, as in the reduction of an overcontoured restoration, or undesirable as in the production of cervical abrasion cavities. A variety of methods, including clinical testing, the use of wear machines and the measurement of related properties such as hardness or coefficient of friction have been used to investigate wear of tooth tissue and of dental materials. Because these methods may not reveal the nature of the wear process recent work has been directed to the study of surface failure resulting from a single sliding contact. Many clinical studies have been conducted but they are time consuming and difficult to quantify, nor do they allow of evaluation of different parameters contributing to the wear. Laboratory simulation of wear has been shown to be valuable in comparing materials of the same group but between-group comparisons may give anomalous results. The most rewarding studies have been those using a single or small number of passes of a suitable abrading point over the material since these permit determination of the actual process by which wear is produced.
Kasten, Benjamin B; Ma, Xiaowei; Cheng, Kai; Bu, Lihong; Slocumb, Winston S; Hayes, Thomas R; Trabue, Steven; Cheng, Zhen; Benny, Paul D
2016-01-20
Developing new strategies to rapidly incorporate the fac-[M(I)(CO)3](+) (M = Re, (99m)Tc) core into biological targeting vectors in radiopharmaceuticals continues to expand as molecules become more complex and as efforts to minimize nonspecific binding increase. This work examines a novel isothiocyanate-functionalized bifunctional chelate based on 2,2'-dipicolylamine (DPA) specifically designed for complexing the fac-[M(I)(CO)3](+) core. Two strategies (postlabeling and prelabeling) were explored using the isothiocyanate-functionalized DPA to determine the effectiveness of assembly on the overall yield and purity of the complex with amine containing biomolecules. A model amino acid (lysine) examined (1) amine conjugation of isothiocyanate-functionalized DPA followed by complexation with fac-[M(I)(CO)3](+) (postlabeling) and (2) complexation of fac-[M(I)(CO)3](+) with isothiocyanate-functionalized DPA followed by amine conjugation (prelabeling). Conducted with stable Re and radioactive (99m)Tc analogs, both strategies formed the product in good to excellent yields under macroscopic and radiotracer concentrations. A synthetic peptide (AE105) which targets an emerging biomarker in CaP prognosis, urokinase-type plasminogen activator receptor (uPAR), was also explored using the isothiocyanate-functionalized DPA strategy. In vitro PC-3 (uPAR+) cell uptake assays with the (99m)Tc-labeled peptide (8a) showed 4.2 ± 0.5% uptake at 4 h. In a murine model bearing PC-3 tumor xenografts, in vivo biodistribution of 8a led to favorable tumor uptake (3.7 ± 0.7% ID/g) at 4 h p.i. with relatively low accumulation (<2% ID/g) in normal organs not associated with normal peptide excretion. These results illustrate the promise of the isothiocyanate-functionalized approach for labeling amine containing biological targeting vectors with fac-[M(I)(CO)3](+).
Conjoint corrosion and wear in titanium alloys.
Khan, M A; Williams, R L; Williams, D F
1999-04-01
When considering titanium alloys for orthopaedic applications it is important to examine the conjoint action of corrosion and wear. In this study we investigate the corrosion and wear behaviour of Ti-6Al-4V, Ti-6Al-7Nb and Ti-13Nb-13Zr in phosphate buffered saline (PBS), bovine albumin solutions in PBS and 10% foetal calf serum solutions in PBS. The tests were performed under four different conditions to evaluate the influence of wear on the corrosion and corrosion on the wear behaviour as follows: corrosion without wear, wear-accelerated corrosion, wear in a non-corrosive environment and wear in a corrosive environment. The corrosion behaviour was investigated using cyclic polarisation studies to measure the ability of the surface to repassivate following breakdown of the passive layer. The properties of the repassivated layer were evaluated by measuring changes in the surface hardness of the alloys. The amount of wear that had occurred was assessed from weight changes and measurement of the depth of the wear scar. It was found that in the presence of wear without corrosion the wear behaviour of Ti-13Nb-13Zr was greater than that of Ti-6Al-7Nb or Ti-6Al-4V and that in the presence of proteins the wear of all three alloys is reduced. In the presence of corrosion without wear Ti-13Nb-13Zr was more corrosion resistant than Ti-6Al-7Nb which was more corrosion resistant than Ti-6Al-4V without proteins whereas in the presence of protein the corrosion resistance of Ti-13Nb-13Zr and Ti-6Al-7Nb was reduced and that of Ti-6Al-4V increased. In the presence of corrosion and wear the corrosion resistance of Ti-13Nb-13Zr is higher than that of Ti-6Al-7Nb or Ti-6Al-4V in PBS but in the presence of proteins the corrosion resistance of Ti-13Nb-13Zr and Ti-6Al-7Nb are very similar but higher than that of Ti-6Al-4V. The wear of Ti-13Nb-13Zr is lower than that of Ti-6Al-7Nb and Ti-6Al-4V with or without the presence of proteins in a corrosive environment. Therefore the overall
Nunziante Cesaro, Stella; Lemorini, Cristina
2012-02-01
The application of combined use-wear analysis and FTIR micro spectroscopy for the investigation of the flint and obsidian tools from the archaeological sites of Masseria Candelaro (Foggia, Italy) and Sant'Anna di Oria (Brindisi, Italy) aiming to clarify their functional use is described. The tools excavated in the former site showed in a very high percentage spectroscopically detectable residues on their working edges. The identification of micro deposits is based on comparison with a great number of replicas studied in the same experimental conditions. FTIR data confirmed in almost all cases the use-wear analysis suggestions and added details about the material processed and about the working procedures. Copyright © 2011 Elsevier B.V. All rights reserved.
Wear particle analysis using the ferrograph
NASA Technical Reports Server (NTRS)
Jones, W. R., Jr.
1983-01-01
The use of the Ferrograph in analyzing wear particles from a variety of different sources is reported. Examples of wear particles from gas turbine engines, bearing tests, friction and wear tests, hydraulic systems, and human joints are illustrated. In addition, the separation of bacteria and human cells is described.
The use of analytical surface tools in the fundamental study of wear. [atomic nature of wear
NASA Technical Reports Server (NTRS)
Buckley, D. H.
1977-01-01
Various techniques and surface tools available for the study of the atomic nature of the wear of materials are reviewed These include chemical etching, x-ray diffraction, electron diffraction, scanning electron microscopy, low-energy electron diffraction, Auger emission spectroscopy analysis, electron spectroscopy for chemical analysis, field ion microscopy, and the atom probe. Properties of the surface and wear surface regions which affect wear, such as surface energy, crystal structure, crystallographic orientation, mode of dislocation behavior, and cohesive binding, are discussed. A number of mechanisms involved in the generation of wear particles are identified with the aid of the aforementioned tools.
Fibro/Adipogenic Progenitors (FAPs): Isolation by FACS and Culture.
Low, Marcela; Eisner, Christine; Rossi, Fabio
2017-01-01
Fibro/adipogenic progenitors (FAPs ) are tissue-resident mesenchymal stromal cells (MSCs). Current literature supports a role for these cells in the homeostasis and repair of multiple tissues suggesting that FAPs may have extensive therapeutic potential in the treatment of numerous diseases. In this context, it is crucial to establish efficient and reproducible procedures to purify FAP populations from various tissues. Here, we describe a protocol for the isolation and cell culture of FAPs from murine skeletal muscle using fluorescence -activated cell sorting (FACS), which is particularly useful for experiments where high cell purity is an essential requirement. Identification, isolation, and cell culture of FAPs represent powerful tools that will help us to understand the role of these cells in different conditions and facilitate the development of safe and effective new treatments for diseases.
Wear resistance of ductile irons
NASA Astrophysics Data System (ADS)
Lerner, Y. S.
1994-06-01
This study was undertaken to evaluate the wear resistance of different grades of ductile iron as alterna-tives to high- tensile- strength alloyed and inoculated gray irons and bronzes for machine- tool and high-pressure hydraulic components. Special test methods were employed to simulate typical conditions of reciprocating sliding wear with and without abrasive- contaminated lubricant for machine and press guideways. Quantitative relationships were established among wear rate, microstructure and micro-hardness of structural constituents, and nodule size of ductile iron. The frictional wear resistance of duc-tile iron as a bearing material was tested with hardened steel shafts using standard test techniques under continuous rotating movement with lubricant. Lubricated sliding wear tests on specimens and compo-nents for hydraulic equipment and apparatus were carried out on a special rig with reciprocating motion, simulating the working conditions in a piston/cylinder unit in a pressure range from 5 to 32 MPa. Rig and field tests on machine- tool components and units and on hydraulic parts have confirmed the test data.
Schott, Timm C; Menne, Dieter
2018-07-01
A broad spectrum of colors for removable appliances, intended to optimize acceptance of treatment and patient cooperation, have been available on the dental market for years. This is the first study to analyze how patient-selected colors are reflected in wear times and wear behavior of removable appliances. The study included 117 children (55 girls and 62 boys) who were treated with active removable plate or functional appliances. All patients were offered to choose from 11 different colors, which were pooled into six groups (black, blue, green, yellow, pink, red) for analysis, or to combine any two to four colors ("multicolored" group) for their appliances. All appliances featured a built-in microsensor (TheraMon; MC Technology, Hargelsberg, Austria) for objective wear-time tracking. Differences between wear times were analyzed using pairwise t tests and Tukey correction. The longest median wear times were recorded in the blue and green groups (≈11 h/d) and the shortest ones in the red and pink groups (≈9 h/d), but they were not significantly influenced by the patient-selected colors. The median wear times involved an age-related decrease by 0.56 h/y that was statistically significant ( P = .00005). No gender-specific patterns of wear behavior were observed. Patient-selected colors for removable appliances can presumably improve acceptance of treatment, but they are not associated with statistically significant improvements in wear time or wear behavior.
Simulation of wear in overhead current collection systems
NASA Astrophysics Data System (ADS)
Klapas, D.; Benson, F. A.; Hackam, R.
1985-09-01
Apparatus have been designed to simulate the wear from conductors in a railway current collection system. The main features of the wear machine include a continuous monitoring of the strip wear, strip traversing, and dwell-time test facilities for the investigation of oxidational wear on a copper disk, simulating the contact wire. Disk wear is measured in situ by the spherical indentations method. Typical results of the specific wear rate are also presented to demonstrate the capability of the apparatus.
[Tooth wear, a proposal for an evaluation system].
Wetselaar, P; van der Zaag, J; Lobbezoo, F
2011-06-01
The present-day terminology and definitions of tooth wear are not unambiguous. For diagnosing tooth wear, however, it is essential that they are unambiguous. In this article a proposal is presented for a tooth wear evaluation system with simplified definitions. This system consists ofa number of modules and can be used for various aspects of the diagnostic procedure. It can be used for the quantification of tooth wear, both for periodic screening and for the monitoring of tooth wear in individual patients. The scoring of occlusal/incisal tooth wear as well as of non-occlusal/non-incisal tooth wear is possible. The evaluative system is also suitable for determining which type of tooth wear, such as attrition, abrasion and erosion, is most likely to have caused any observed loss of hard tooth tissue.
Polyethylene Wear in Retrieved Reverse Total Shoulder Components
Day, Judd S; MacDonald, Daniel W; Olsen, Madeline; Getz, Charles; Williams, Gerald R; Kurtz, Steven M
2011-01-01
Background Reverse total shoulder arthroplasty has been used to treat rotator cuff tear arthropathy, proximal humeral fractures and for failed conventional total shoulder prostheses. It has been suggested that polyethylene wear is potentially higher in reverse shoulder replacements than in conventional shoulder replacements. The modes and degree of polyethylene wear have not been completely elucidated. The purpose of this study was to evaluate polyethylene wear patterns in seven specimens retrieved at revision arthroplasty and identify factors that may be associated with increased wear. Methods Reverse total shoulder components were retrieved from 7 patients during revision arthroplasty for loosening and/or pain. Pre-operative glenoid tilt and placement, and scapular notching were evaluated using pre-operative radiographs. Polyethylene wear was evaluated using microCT and optical microscopy. Results Wear on the rim of the polyethylene humeral cup, was identified on all retrieved components. The extent of rim wear varied from a penetration depth of 0.1 to 4.7 mm. We could not demonstrate a correlation between scapular notching and rim wear. However, rim wear was more extensive when the inferior screw had made contact with the liner. Metal on metal wear between the humeral component and the inferior screw of one component was also observed. Wear of the intended bearing surface was minimal. Discussion Rim damage was the predominant cause of polyethylene wear in our retrieved specimens. Direct contact between the humeral component and inferior metaglene screws is concerning because this could lead to accelerated UHMWPE wear and also induce mechanical loosening of the glenoid component. PMID:21724419
NASA Astrophysics Data System (ADS)
Mukhametzyanova, G. F.; Kolesnikov, MS; Mukhametzyanov, I. R.; Astatshenko, V. I.
2017-09-01
The kinetics and reasons for metallic pipe wear of hot chamberzinc alloy die casting machines are established.Increasing metallic pipe wear components wear resistance is being achieved by means of die steelДИ - 22 with electroslag remelting modification and electron-beamremelting modification and after the processes of nitriding and boriding besides.
NASA Astrophysics Data System (ADS)
Chetan; Narasimhulu, A.; Ghosh, S.; Rao, P. V.
2015-07-01
Machinability of titanium is poor due to its low thermal conductivity and high chemical affinity. Lower thermal conductivity of titanium alloy is undesirable on the part of cutting tool causing extensive tool wear. The main task of this work is to predict the various wear mechanisms involved during machining of Ti alloy (Ti6Al4V) and to formulate an analytical mathematical tool wear model for the same. It has been found from various experiments that adhesive and diffusion wear are the dominating wear during machining of Ti alloy with PVD coated tungsten carbide tool. It is also clear from the experiments that the tool wear increases with the increase in cutting parameters like speed, feed and depth of cut. The wear model was validated by carrying out dry machining of Ti alloy at suitable cutting conditions. It has been found that the wear model is able to predict the flank wear suitably under gentle cutting conditions.
NASA Astrophysics Data System (ADS)
Ben Mahmud, Tarek A.; Atieh, Anas M.; Khan, Tahir I.
2017-07-01
The ability to deposit nanostructured feedstock by using high-velocity oxygen-fuel (HVOF) spray offers potential improvements in coating hardness, wear resistance and toughness for applications in the oil sands industry. In this study, the wear behavior of a near-nanostructured coating was compared under dry and slurry abrasive wear test using an uncoated AISI-1018 low-carbon steel substrate as a reference. The coating microstructures were analyzed in the as-sprayed, dry and slurry test conditions using scanning electron microscopy, x-ray diffraction and microhardness measurements. Wear behavior of the steel and coating surfaces were assessed using a pin-on-plate wear test under various loads. The results showed that a coating could be successfully deposited using the HVOF spraying technique and with retention of the near-nanosized WC dispersion within the coating structure. The wear rate under dry test conditions was greater for the steel and coating compared to tests performed under slurry conditions. Examination of the wear tracks revealed that the wear mechanism was different for the two test conditions. Wear in the dry test condition resulted from 2-body abrasion, while 3-body abrasion dominated wear in slurry conditions. The latter showed lower wear rates due to a lubricating effect of the oil.
NASA Astrophysics Data System (ADS)
Kim, Kyu-Tae
2013-02-01
In order to investigate whether or not the grid-to-rod fretting wear-induced fuel failure will occur for newly developed spacer grid spring designs for the fuel lifetime, out-of-pile fretting wear tests with one or two fuel assemblies are to be performed. In this study, the out-of-pile fretting wear tests were performed in order to compare the potential for wear-induced fuel failure in two newly-developed, Korean PWR spacer grid designs. Lasting 20 days, the tests simulated maximum grid-to-rod gap conditions and the worst flow induced vibration effects that might take place over the fuel life time. The fuel rod perforation times calculated from the out-of-pile tests are greater than 1933 days for 2 μm oxidized fuel rods with a 100 μm grid-to-rod gap, whereas those estimated from in-reactor fretting wear failure database may be about in the range of between 60 and 100 days. This large discrepancy in fuel rod perforation may occur due to irradiation-induced cladding oxide microstructure changes on the one hand and a temperature gradient-induced hydrogen content profile across the cladding metal region on the other hand, which may accelerate brittleness in the grid-contacting cladding oxide and metal regions during the reactor operation. A three-phase grid-to-rod fretting wear model is proposed to simulate in-reactor fretting wear progress into the cladding, considering the microstructure changes of the cladding oxide and the hydrogen content profile across the cladding metal region combined with the temperature gradient. The out-of-pile tests cannot be directly applicable to the prediction of in-reactor fretting wear-induced cladding perforations but they can be used only for evaluating a relative wear resistance of one grid design against the other grid design.
Fault Wear and Friction Evolution: Experimental Analysis
NASA Astrophysics Data System (ADS)
Boneh, Y.; Chang, J. C.; Lockner, D. A.; Reches, Z.
2011-12-01
Wear is an inevitable product of frictional sliding of brittle rocks as evidenced by the ubiquitous occurrence of fault gouge and slickenside striations. We present here experimental observations designed to demonstrate the relationship between wear and friction and their governing mechanisms. The experiments were conducted with a rotary shear apparatus on solid, ring-shaped rock samples that slipped for displacements up to tens of meters. Stresses, wear and temperature were continuously monitored. We analyzed 86 experiments of Kasota dolomite, Sierra White granite, Pennsylvania quartzite, Karoo gabbro, and Tennessee sandstone at slip velocities ranging from 0.002 to 0.97 m/s, and normal stress from 0.25 to 6.9 MPa. We conducted two types of runs: short slip experiments (slip distance < 25 mm) primarily on fresh, surface-ground samples, designed to analyze initial wear mechanisms; and long slip experiments (slip distance > 3 m) designed to achieve mature wear conditions and to observe the evolution of wear and friction as the fault surfaces evolved. The experiments reveal three wear stages: initial, running-in, and steady-state. The initial stage is characterized by (1) discrete damage striations, the length of which is comparable to total slip , and local pits or plow features; (2) timing and magnitude of fault-normal dilation corresponds to transient changes of normal and shear stresses; and (3) surface roughness increasing with the applied normal stress. We interpret these observations as wear mechanisms of (a) plowing into the fresh rock surfaces; (b) asperity breakage; and (c) asperity climb. The running-in stage is characterized by (1) intense wear-rate over a critical wear distance of Rd = 0.3-2 m; (2) drop of friction coefficient over a weakening distance of Dc = 0.2-4 m; (3) Rd and Dc display positive, quasi-linear relation with each other. We interpret these observations as indicating the organizing of newly-created wear particles into a 'three
An evaluation of 1-day disposable contact lens wear in a population of allergy sufferers.
Hayes, Valérie Y; Schnider, Cristina M; Veys, Jane
2003-06-01
This was a multi-site, 128-subject, bilateral crossover study to evaluate subjective comfort and slit-lamp findings with 1-day disposable contact lenses in a population of allergy sufferers during periods when allergen levels were elevated. The study involved 1-month of single-use daily wear with a 1-day disposable test lens (1. DAY ACUVUE Brand Contact Lenses, Johnson & Johnson Vision Care) and 1-month of daily wear with subjects' habitual lenses replaced to their usual replacement schedule. Pollen and mould counts were obtained for each site 1 week prior to the study and twice weekly throughout the study period. Subjective comfort and slit-lamp findings were recorded at baseline and after 1-month's wear of each modality. Sixty-seven percent of subjects agreed that the 1-day disposable lenses provided improved comfort when compared to the lenses they wore prior to the study, compared with 18% agreeing that the new pair of habitual lenses provided improved comfort. The 1-day disposable lenses showed greater improvement in slit-lamp findings from baseline than new habitual lenses. The use of 1-day disposable lenses is an effective strategy for managing allergy-suffering contact lens wearers.
A Phenomenological Approach to Wear Debris Analysis
1996-04-01
Ferrography ; oil analysis; wear debris analysis Introduction: Wear debris analysis is an important subject in maintenance, especially condition...diagnostic ol can be traced to Ferrography developed in the early 1970’s. Westcott and Seifert [1] state e heart and soul of Ferrography , or optical debris...monitoring, as follows. The key to Ferrography or optical examination of wear debris is to find marks or features on wear debris which suggest likely
Site Rehabilitation Completion Report with No Further Action Proposal for the Northeast Site
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daniel, Joe; Tabor, Charles; Survochak, Scott
2013-05-01
The purpose of this Site Rehabilitation Completion Report is to present the post-active-remediation monitoring results for the Northeast Site and to propose No Further Action with Controls. This document includes information required by Chapter 62-780.750(4)(d), 62-780.750(6), and 62-780.600(8)(a)27 Florida Administrative Code (F.A.C.). The Closure Monitoring Plan for the Northeast Site and 4.5 Acre Site (DOE 2009a) describes the approach for post-active-remediation monitoring. The Young - Rainey Science, Technology, and Research Center (STAR Center) is a former U.S. Department of Energy (DOE) facility constructed in the mid-1950s. The 99-acre STAR Center is located in Largo, Florida. The Northeast Site is locatedmore » in the northeast corner of the STAR Center. The Northeast Site meets all the requirements for an RMO II closure—No Further Action with Controls. DOE is nearing completion of a restrictive covenant for the Northeast Site. DOE has completed post-active-remediation monitoring at the Northeast Site as of September 2012. No additional monitoring will be conducted.« less
Ferrographic analysis of wear particles from sliding elastohydrodynamic experiments
NASA Technical Reports Server (NTRS)
Jones, W. R., Jr.; Nagaraj, H. S.; Winer, W. O.
1978-01-01
The Ferrograph was used to analyze wear debris generated in a sliding elastohydrodynamic contact. The amount of wear debris correlates well with the ratio of film thickness to composite surface roughness (A ratio). The general wear level parameter and the wear severity index yielded similar correlations with average A ratios. Essentially all the generated wear particles were of the normal rubbing wear type. The Ferrograph was more sensitive in detecting the wear debris than was the commonly used emission spectrograph.
On the debris-level origins of adhesive wear.
Aghababaei, Ramin; Warner, Derek H; Molinari, Jean-François
2017-07-25
Every contacting surface inevitably experiences wear. Predicting the exact amount of material loss due to wear relies on empirical data and cannot be obtained from any physical model. Here, we analyze and quantify wear at the most fundamental level, i.e., wear debris particles. Our simulations show that the asperity junction size dictates the debris volume, revealing the origins of the long-standing hypothesized correlation between the wear volume and the real contact area. No correlation, however, is found between the debris volume and the normal applied force at the debris level. Alternatively, we show that the junction size controls the tangential force and sliding distance such that their product, i.e., the tangential work, is always proportional to the debris volume, with a proportionality constant of 1 over the junction shear strength. This study provides an estimation of the debris volume without any empirical factor, resulting in a wear coefficient of unity at the debris level. Discrepant microscopic and macroscopic wear observations and models are then contextualized on the basis of this understanding. This finding offers a way to characterize the wear volume in atomistic simulations and atomic force microscope wear experiments. It also provides a fundamental basis for predicting the wear coefficient for sliding rough contacts, given the statistics of junction clusters sizes.
On the debris-level origins of adhesive wear
NASA Astrophysics Data System (ADS)
Aghababaei, Ramin; Warner, Derek H.; Molinari, Jean-François
2017-07-01
Every contacting surface inevitably experiences wear. Predicting the exact amount of material loss due to wear relies on empirical data and cannot be obtained from any physical model. Here, we analyze and quantify wear at the most fundamental level, i.e., wear debris particles. Our simulations show that the asperity junction size dictates the debris volume, revealing the origins of the long-standing hypothesized correlation between the wear volume and the real contact area. No correlation, however, is found between the debris volume and the normal applied force at the debris level. Alternatively, we show that the junction size controls the tangential force and sliding distance such that their product, i.e., the tangential work, is always proportional to the debris volume, with a proportionality constant of 1 over the junction shear strength. This study provides an estimation of the debris volume without any empirical factor, resulting in a wear coefficient of unity at the debris level. Discrepant microscopic and macroscopic wear observations and models are then contextualized on the basis of this understanding. This finding offers a way to characterize the wear volume in atomistic simulations and atomic force microscope wear experiments. It also provides a fundamental basis for predicting the wear coefficient for sliding rough contacts, given the statistics of junction clusters sizes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stavropoulos, D.J.; Tomkins, D.J.; Allingham-Hawkins, D.J.
1994-09-01
Cells from all four Fanconi anemia complementation groups show hypersensitivity to cell-killing by mitomycin C (MMC), diepoxybutane (DEB) and other DNA cross-linking agents, and increased spontaneous and DEB-induced chromosome aberrations (CA). The extent of these phenotypes varies between lymphoblastoid cell lines from different complementation groups. Our data showed that the difference in MMC hypersensitivity and DEB-CA was not always coupled. While 230N (FA-B) had higher DEB-induced CA/cell than 536N (FA-C) (7.42 vs. 4.46 respectively), that latter was much more sensitive to cell-killing by MMC (dose at 10% survival, D{sub 10}: 5.2 vs. 1.2 ng/ml respectively). Strathdes et al. (1992) clonedmore » a cDNA Fanconi anemia complementation group C (FACC) which complemented the hypersensitivity to MMC and DEB cell-killing of FA-C cells (536N) but not cells from the other three complementation groups. The present study was initiated to determine whether chromosome instability in 536N is also complemented by the FACC (FAC3) cDNA. The pREP4-FAC3 vector was transfected into 536N and transfectants selected with hygromycin B. The DEB D{sub 10} of 536N (1.0 {mu}M) was corrected to the control level (16.2 {mu}M for 3TO) by FACC (15.1 {mu}M for 536N-FACC), as previously demonstrated. Chromosome instability (cab, cse, ctb, cte) was determined without and with 0.1 {mu}g/ml DEB treatment. Spontaneous CA of 536N (0.30 aberrations/cell) was corrected to the control level (0.04 for 3TO) by FACC (0.06 for 536N-FACC). Similarly, the DEB-induced CA was corrected (2.74 for 536N vs. 0.06 and 0.02 for 3TO and 536N-FACC respectively). Thus, at least for FA complementation group C, hypersensitivity to cell-killing and chromosome instability are not dissociated and are most likely caused by the same gene defect.« less
Wear Behavior of an Ultra-High-Strength Eutectoid Steel
NASA Astrophysics Data System (ADS)
Mishra, Alok; Maity, Joydeep
2018-02-01
Wear behavior of an ultra-high-strength AISI 1080 steel developed through incomplete austenitization-based combined cyclic heat treatment is investigated in comparison with annealed and conventional hardened and tempered conditions against an alumina disk (sliding speed = 1 m s-1) using a pin-on-disk tribometer at a load range of 7.35-14.7 N. On a gross scale, the mechanism of surface damage involves adhesive wear coupled with abrasive wear (microcutting effects in particular) at lower loads. At higher loads, mainly the abrasive wear (both microcutting and microploughing mechanisms) and evolution of adherent oxide are observed. Besides, microhardness of matrix increases with load indicating substantial strain hardening during wear test. The rate of overall wear is found to increase with load. As-received annealed steel with the lowest initial hardness suffers from severe abrasive wear, thereby exhibiting the highest wear loss. Such a severe wear loss is not observed in conventional hardened and tempered and combined cyclic heat treatment conditions. Combined cyclic heat-treated steel exhibits the greatest wear resistance (lowest wear loss) due to its initial high hardness and evolution of hard abrasion-resistant tribolayer during wear test at higher load.
Compact friction and wear machine
NASA Astrophysics Data System (ADS)
Hannigan, James W.; Schwarz, Ricardo B.
1988-08-01
We have developed a compact ring-on-ring wear machine that measures the friction coefficient between large area surfaces as a function of time, normal stress, and sliding velocity. The machine measures the temperature of the sliding surfaces and collects the wear debris.
On the debris-level origins of adhesive wear
Warner, Derek H.; Molinari, Jean-François
2017-01-01
Every contacting surface inevitably experiences wear. Predicting the exact amount of material loss due to wear relies on empirical data and cannot be obtained from any physical model. Here, we analyze and quantify wear at the most fundamental level, i.e., wear debris particles. Our simulations show that the asperity junction size dictates the debris volume, revealing the origins of the long-standing hypothesized correlation between the wear volume and the real contact area. No correlation, however, is found between the debris volume and the normal applied force at the debris level. Alternatively, we show that the junction size controls the tangential force and sliding distance such that their product, i.e., the tangential work, is always proportional to the debris volume, with a proportionality constant of 1 over the junction shear strength. This study provides an estimation of the debris volume without any empirical factor, resulting in a wear coefficient of unity at the debris level. Discrepant microscopic and macroscopic wear observations and models are then contextualized on the basis of this understanding. This finding offers a way to characterize the wear volume in atomistic simulations and atomic force microscope wear experiments. It also provides a fundamental basis for predicting the wear coefficient for sliding rough contacts, given the statistics of junction clusters sizes. PMID:28696291
Wear Calculation Approach for Sliding - Friction Pairs
NASA Astrophysics Data System (ADS)
Springis, G.; Rudzitis, J.; Lungevics, J.; Berzins, K.
2017-05-01
One of the most important things how to predict the service life of different products is always connected with the choice of adequate method. With the development of production technologies and measuring devices and with ever increasing precision one can get the appropriate data to be used in analytic calculations. Historically one can find several theoretical wear calculation methods but still there are no exact wear calculation model that could be applied to all cases of wear processes because of difficulties connected with a variety of parameters that are involved in wear process of two or several surfaces. Analysing the wear prediction theories that could be classified into definite groups one can state that each of them has shortcomings that might impact the results thus making unnecessary theoretical calculations. The offered wear calculation method is based on the theories of different branches of science. It includes the description of 3D surface micro-topography using standardized roughness parameters, explains the regularities of particle separation from the material in the wear process using fatigue theory and takes into account material’s physical and mechanical characteristics and definite conditions of product’s working time. The proposed wear calculation model could be of value for prediction of the exploitation time for sliding friction pairs thus allowing the best technologies to be chosen for many mechanical details.
Investigation of wear phenomena by microscopy
NASA Technical Reports Server (NTRS)
Buckley, D. H.
1982-01-01
The various wear mechanisms involved in the loss of material from metallic and nonmetallic surfaces are discussed. The results presented indicate how various microscopy techniques used in conjunction with other analytical tools can assist in the elucidation of a wear mechanism. Without question, microscopy is the single most important tool for the study of the wear of surfaces, to assess and address inherent mechanisms of the material removal process.
Mörmann, Werner H; Stawarczyk, Bogna; Ender, Andreas; Sener, Beatrice; Attin, Thomas; Mehl, Albert
2013-04-01
This study determined the two-body wear and toothbrushing wear parameters, including gloss and roughness measurements and additionally Martens hardness, of nine aesthetic CAD/CAM materials, one direct resin-based nanocomposite plus that of human enamel as a control group. Two-body wear was investigated in a computer-controlled chewing simulator (1.2 million loadings, 49N at 1.7Hz; 3000 thermocycles 5/50°C). Each of the 11 groups consisted of 12 specimens and 12 enamel antagonists. Quantitative analysis of wear was carried out with a 3D-surface analyser. Gloss and roughness measurements were evaluated using a glossmeter and an inductive surface profilometer before and after abrasive toothbrushing of machine-polished specimens. Additionally Martens hardness was measured. Statistically significant differences were calculated with one-way ANOVA (analysis of variance). Statistically significant differences were found for two-body wear, gloss, surface roughness and hardness. Zirconium dioxide ceramics showed no material wear and low wear of the enamel antagonist. Two-body wear of CAD/CAM-silicate and -lithium disilicate ceramics, -hybrid ceramics and -nanocomposite as well as direct nanocomposite did not differ significantly from that of human enamel. Temporary polymers showed significantly higher material wear than permanent materials. Abrasive toothbrushing significantly reduced gloss and increased roughness of all materials except zirconium dioxide ceramics. Gloss retention was highest with zirconium dioxide ceramics, silicate ceramics, hybrid ceramics and nanocomposites. Temporary polymers showed least gloss retention. Martens hardness differed significantly among ceramics, between ceramics and composites, and between resin composites and acrylic block materials as well. All permanent aesthetic CAD/CAM block materials tested behave similarly or better with respect to two-body wear and toothbrushing wear than human enamel, which is not true for temporary polymer CAD
Thermomechanical Contact Phenomena and Wear of Sliding Components
1989-07-31
seals. Many of those methods were used in this study. • • I I i II I I I I I I I l1 2. METHDS Sliding wear tests were conducted on Inconel 625 seal rings...wear. These coatings have been used successfully in reducing the wear of machine tools , aircraft and automobile engine parts, etc. It is only recently...scanning electron microscopy were tools employed to determine the wear behavior and wear mechanism associated with the various chromium carbide and tungsten
The role of oxidation in the fretting wear process
NASA Technical Reports Server (NTRS)
Bill, R. C.
1980-01-01
Fretting experiments were conducted on titanium, a series of Ni-Cr-Al alloys and on some high temperature turbine alloys at room temperature and at elevated temperatures in air and in various inert environments. It was found that, depending on temperature and environment, the fretting behavior of the materials examined could be classified according to four general types of behavior. Briefly, these types of behavior were: (1) the complete absence of oxidation, as in inert environments, generally leading to low rates of fretting wear but high fretting friction; (2) gradual attrition of surface oxide with each fretting stroke, found in these experiments to operate in concert with other dominating mechanisms; (3) rapid oxidation at surface fatigue damage sites, resulting in undermining and rapid disintegration of the load bearing surface; and (4) the formation of coherent, protective oxide film, resulting in low rates of fretting wear. An analytical model predicting conditions favorable to the fourth type of behavior was outlined.
Wear Characteristics of Metallic Biomaterials: A Review
Hussein, Mohamed A.; Mohammed, Abdul Samad; Al-Aqeeli, Naser
2015-01-01
Metals are extensively used in a variety of applications in the medical field for internal support and biological tissue replacements, such as joint replacements, dental roots, orthopedic fixation, and stents. The metals and alloys that are primarily used in biomedical applications are stainless steels, Co alloys, and Ti alloys. The service period of a metallic biomaterial is determined by its abrasion and wear resistance. A reduction in the wear resistance of the implant results in the release of incompatible metal ions into the body that loosen the implant. In addition, several reactions may occur because of the deposition of wear debris in tissue. Therefore, developing biomaterials with high wear resistance is critical to ensuring a long life for the biomaterial. The aim of this work is to review the current state of knowledge of the wear of metallic biomaterials and how wear is affected by the material properties and conditions in terms of the type of alloys developed and fabrication processes. We also present a brief evaluation of various experimental test techniques and wear characterization techniques that are used to determine the tribological performance of metallic biomaterials.
Experience with wear-resistant materials at the Homer City Coal Cleaning Plant
DOE Office of Scientific and Technical Information (OSTI.GOV)
Williams, W.R.
1984-10-01
The Homer City preparation plant is a multi-stream, dual-circuit facility with a capacity of 1200 ton/hour raw feed. It serves 3 units of a neighbouring power station. Experience with a number of wear and corrosion resistant materials is described. It is emphasised that the successes and failures reported may be site-specific.
Esthetic restorative materials and opposing enamel wear.
Olivera, Anna Belsuzarri; Marques, Márcia Martins
2008-01-01
This in vitro study compared the effects of a gold alloy (Degulor M), four dental ceramics (IPS Empress, IPS Empress 2, Duceram Plus, Duceram LFC) and a laboratory-processed composite (Targis) on the wear of human enamel. The amount of wear of the enamel (dental cusps) and restorative materials (disks) were tested in water at 37 degrees C under standard load (20 N), with a chewing rate of 1.3 Hz and was determined after 150,000 and 300,000 cycles. Before the test, the average surface roughness of the restorative materials was analyzed using the Ra parameter. The results of this study indicate that Targis caused enamel wear similar to Degulor M and resulted in significantly less wear than all the ceramics tested. IPS Empress provoked the greatest amount of enamel wear and Degulor M caused less vertical dimension loss. Targis could be an appropriate alternative material to ceramic, because it is esthetic and produces opposing enamel wear comparable to gold alloy.
Tool wear compensation scheme for DTM
NASA Astrophysics Data System (ADS)
Sandeep, K.; Rao, U. S.; Balasubramaniam, R.
2018-04-01
This paper is aimed to monitor tool wear in diamond turn machining (DTM), assess effects of tool wear on accuracies of the machined component, and develop compensation methodology to enhance size and shape accuracies of a hemispherical cup. In order to find change in the centre and radius of tool with increasing wear of tool, a MATLAB program is used. In practice, x-offsets are readjusted by DTM operator for desired accuracy in the cup and the results of theoretical model show that change in radius and z-offset are insignificant however x-offset is proportional to the tool wear and this is what assumed while resetting tool offset. Since we could not measure the profile of tool; therefore we modeled our program for cup profile data. If we assume no error due to slide and spindle of DTM then any wear in the tool will be reflected in the cup profile. As the cup data contains surface roughness, therefore random noise similar to surface waviness is added. It is observed that surface roughness affects the centre and radius but pattern of shifting of centre with increase in wear of tool remains similar to the ideal condition, i.e. without surface roughness.
Peripheral corneal infiltrates associated with contact lens wear.
Donshik, P C; Suchecki, J K; Ehlers, W H
1995-01-01
PURPOSE: A retrospective study was performed to review the clinical characteristics of peripheral corneal infiltrates in contact lens wearers. METHODS: The charts of all contact lens patients with peripheral corneal infiltrates 1.5 mm or less in size who presented to the office from 1987 to 1994 were reviewed. RESULTS: The epidemiological and clinical characteristics of peripheral corneal infiltrates associated with contact lens wear were reviewed in 52 patients (64 infiltrates). Forty-four patients presented with a single infiltrate, while the remaining 8 patients had multiple infiltrates. While there was no predilection for a specific quadrant of the cornea, when a subgroup of patients who wore extended wear lenses was analyzed, 19 of the 40 infiltrates were located in the superior quadrant. Forty percent of the patients were wearing disposable extended wear contact lenses, 21% were wearing conventional extended wear lenses, 33% were wearing conventional or frequent replacement/disposable daily wear contact lenses and 6% were wearing rigid gas permeable lenses. The majority of patients had minimal conjunctival inflammation, an anterior stromal cellular reaction and minimal anterior chamber activity. A subgroup of 16 patients had corneal cultures of their infiltrates. In this group, 8 of the 16 had positive cultures. All patients had a resolution of the infiltrates without complications and the majority were refitted to daily wear soft or rigid contact lenses. CONCLUSION: Peripheral corneal infiltrates in contact lens wearers appears to be more common in patients wearing extended wear soft contact lenses. While often considered "sterile" in the literature, a significant number have been shown to be culture-positive. The organisms that have been associated with peripheral infiltrates appear to be less "pathogenic" than those that have been reported to be associated with central corneal ulcer. However, it is probably advisable that patients with peripheral corneal
Gaussian process regression for tool wear prediction
NASA Astrophysics Data System (ADS)
Kong, Dongdong; Chen, Yongjie; Li, Ning
2018-05-01
To realize and accelerate the pace of intelligent manufacturing, this paper presents a novel tool wear assessment technique based on the integrated radial basis function based kernel principal component analysis (KPCA_IRBF) and Gaussian process regression (GPR) for real-timely and accurately monitoring the in-process tool wear parameters (flank wear width). The KPCA_IRBF is a kind of new nonlinear dimension-increment technique and firstly proposed for feature fusion. The tool wear predictive value and the corresponding confidence interval are both provided by utilizing the GPR model. Besides, GPR performs better than artificial neural networks (ANN) and support vector machines (SVM) in prediction accuracy since the Gaussian noises can be modeled quantitatively in the GPR model. However, the existence of noises will affect the stability of the confidence interval seriously. In this work, the proposed KPCA_IRBF technique helps to remove the noises and weaken its negative effects so as to make the confidence interval compressed greatly and more smoothed, which is conducive for monitoring the tool wear accurately. Moreover, the selection of kernel parameter in KPCA_IRBF can be easily carried out in a much larger selectable region in comparison with the conventional KPCA_RBF technique, which helps to improve the efficiency of model construction. Ten sets of cutting tests are conducted to validate the effectiveness of the presented tool wear assessment technique. The experimental results show that the in-process flank wear width of tool inserts can be monitored accurately by utilizing the presented tool wear assessment technique which is robust under a variety of cutting conditions. This study lays the foundation for tool wear monitoring in real industrial settings.
Wang, Cheng; Zhou, Wei; Yu, Junfeng; Zhang, Lan; Wang, Ni
2012-01-01
To optimize the conditions for the preparation of the organometallic precursor fac-[¹⁸⁸ReCO₃(H₂O)₃]⁺ and to synthesize the radiolabeling compounds of tricarbonyl rhenium. 1,2,3-Triazole analogs were synthesized by click chemistry and labeled with fac-[ReCO₃(H₂O)₃]Br and fac-[¹⁸⁸ReCO₃(H₂O)₃]⁺. The aim was to improve the methods for the synthesis of ¹⁸⁸Re-labeled radiopharmaceuticals for therapy. With potassium boranocarbonate as the CO source and ammonia borane as the reducing agent, fac-[¹⁸⁸ReCO₃(H₂O)₃]⁺ was synthesized, and the click chemistry method was used to prepare the tricarbonyl rhenium complex. At the optimal reaction condition (the amounts of K₂[H₃BCO₂] and BH₃·NH₃ are 5 and 5 mg, respectively; reaction temperature is 75°C; and reaction time is 15 min), the radiochemical yields were 90%, and the labeling yield of bis(pyridin-2-ylmethyl) amine with fac-[¹⁸⁸ReCO₃(H₂O)₃]⁺ was more than 99% in 1 h at 75°C; the conjugation yields of triazole analog obtained by click chemistry with 'cold' and 'radio' tricarbonyl rhenium were more than 80%. The organometallic precursor fac-[¹⁸⁸ReCO₃(H₂O)₃]⁺ was prepared under optimal reaction conditions with a yield of 90%, and the triazole analogs synthesized by click chemistry were suitable ligands for tricarbonyl rhenium.
Dynamic SEM wear studies of tungsten carbide cermets
NASA Technical Reports Server (NTRS)
Brainard, W. A.; Buckley, D. H.
1975-01-01
Dynamic friction and wear experiments were conducted in a scanning electron microscope. The wear behavior of pure tungsten carbide and composite with 6 and 15 weight percent cobalt binder was examined. Etching of the binder was done to selectively determine the role of the binder in the wear process. Dynamic experiments were conducted as the WC and bonded WC cermet surfaces were transversed by a 50 micron radiused diamond stylus. These studies show that the predominant wear process in WC is fracture initiated by plastic deformation. The wear of the etched cermets is similar to pure WC. The presence of the cobalt binder reduces both friction and wear. The cementing action of the cobalt reduces granular separation and promotes a dense polished layer because of its low shear strength film-forming properties. The wear debris generated from unetched surface is approximately the same composition as the bulk.
The effect of runway surface and braking on Shuttle Orbiter main gear tire wear
NASA Technical Reports Server (NTRS)
Daugherty, Robert H.; Stubbs, Sandy M.
1992-01-01
In 1988, a 1067 m long touchdown zone on each end of the Kennedy Space Center (KSC) Shuttle Landing Facility (SLF) was modified from its original heavy-broom finish with transverse grooves configuration to a longitudinal corduroy surface texture with no transverse grooves. The intent of this modification was to reduce the spin-up wear on the Orbiter main gear tires and provide for somewhat higher crosswind capabilities at that site. The modification worked well, so it was proposed that the remainder of the runway be modified as well to permit even higher crosswind landing capability. Tests were conducted at the NASA Langley Aircraft Landing Dynamics Facility (ALDF) to evaluate the merit of such a modification. This paper discusses the results of these tests, and explains why the proposed modification did not provide the expected improvement and thus was not implemented. Also, in an ongoing program to evaluate the origin of various tire wear phenomenon, a series of tests was conducted to evaluate the effect of braking on tire wear. Finally, a modified tire is discussed in terms of its wear performance under rollout and braking operations.
Lense, Sheri; Piro, Nicholas A; Kassel, Scott W; Wildish, Andrew; Jeffery, Brent
2016-08-01
The structures of two facially coordinated Group VII metal complexes, fac-[ReCl(C10H8N2O2)(CO)3]·C4H8O (I·THF) and fac-[MnBr(C10H8N2O2)(CO)3]·C4H8O (II·THF), are reported. In both complexes, the metal ion is coordinated by three carbonyl ligands, a halide ligand, and a 6,6'-dihy-droxy-2,2'-bi-pyridine ligand in a distorted octa-hedral geometry. Both complexes co-crystallize with a non-coordinating tetra-hydro-furan (THF) solvent mol-ecule and exhibit inter-molecular but not intra-molecular hydrogen bonding. In both crystal structures, chains of complexes are formed due to inter-molecular hydrogen bonding between a hy-droxy group from the 6,6'-dihy-droxy-2,2'-bi-pyridine ligand and the halide ligand from a neighboring complex. The THF mol-ecule is hydrogen bonded to the remaining hy-droxy group.
Interaction between attrition,abrasion and erosion in tooth wear.
Addy, M; Shellis, R P
2006-01-01
Tooth wear is the result of three processes: abrasion (wear produced by interaction between teeth and other materials), attrition (wear through tooth-tooth contact) and erosion (dissolution of hard tissue by acidic substances). A further process (abfraction) might potentiate wear by abrasion and/or erosion. Both clinical and experimental observations show that individual wear mechanisms rarely act alone but interact with each other. The most important interaction is the potentiation of abrasion by erosive damage to the dental hard tissues. This interaction seems to be the major factor in occlusal and cervical wear. The available evidence seems insufficient to establish whether abfraction is an important contributor to tooth wear in vivo. Saliva can modulate erosive/abrasive tooth wear through formation of pellicle and by remineralisation but cannot prevent it.
Microstructural studies of wear mechanisms in cast aluminum alloys
NASA Astrophysics Data System (ADS)
Elmadagli, Mustafa
2005-07-01
The microstructural basis of wear and surface degradation mechanisms in Al-Si alloys has been investigated in order to improve the current understanding of the requirements for wear resistant aluminum alloy design. The wear behaviour of three commercial alloys namely: a sand cast A390 (Al-18.4%Si), a spray formed Al-25%Si, and a die cast 383 (Al-9.5%Si) have been investigated. Dry sliding wear tests were performed using a block on ring type tribometer under controlled environments. The experiments were performed in a load range between 0.2 N and 300 N at a constant speed of 1 m/s. The testing environments were a dry air (5% RH), a humid air (95% RH), and an argon atmosphere. In dry air (5% RH), two main wear regimes namely, mild wear (MW), and severe wear (SW) were identified. The (MW) regime consisted of two sub-regimes: first and second regimes of mild wear, (MW-1) and (MW-2). The mild wear was controlled by the formation and destruction (spallation) of hardened tribolayers composed of Fe, Al, Si, and O which gave rise to steady state wear rates in both sub-regimes. The transition to second sub-regime was attributed to the destabilization and partial removal of the tribolayers on the contact surfaces. Severe wear occurred at loads exceeding 150 N irrespective of the alloy when the contact surface temperature reached a critical value (210-240°C). The wear rates (W) in each sub-regime of the MW obeyed the relation, W=CLn, where C and n were the wear coefficient and the wear exponent, respectively. The wear exponents, n, were similar in each of the sub-regimes for all three alloys, indicating that the same mechanisms controlled the wear rates. However, the wear coefficients, C, and the transition loads to the second sub-regime were considerably different for each alloy. A method of analyzing the wear coefficients and the transition loads of the alloys, based on pair-wise comparison between them, was developed. This method demonstrated that small equiaxed silicon
Wear behavior of austenite containing plate steels
NASA Astrophysics Data System (ADS)
Hensley, Christina E.
As a follow up to Wolfram's Master of Science thesis, samples from the prior work were further investigated. Samples from four steel alloys were selected for investigation, namely AR400F, 9260, Hadfield, and 301 Stainless steels. AR400F is martensitic while the Hadfield and 301 stainless steels are austenitic. The 9260 exhibited a variety of hardness levels and retained austenite contents, achieved by heat treatments, including quench and tempering (Q&T) and quench and partitioning (Q&P). Samples worn by three wear tests, namely Dry Sand/Rubber Wheel (DSRW), impeller tumbler impact abrasion, and Bond abrasion, were examined by optical profilometry. The wear behaviors observed in topography maps were compared to the same in scanning electron microscopy micrographs and both were used to characterize the wear surfaces. Optical profilometry showed that the scratching abrasion present on the wear surface transitioned to gouging abrasion as impact conditions increased (i.e. from DSRW to impeller to Bond abrasion). Optical profilometry roughness measurements were also compared to sample hardness as well as normalized volume loss (NVL) results for each of the three wear tests. The steels displayed a relationship between roughness measurements and observed wear rates for all three categories of wear testing. Nanoindentation was used to investigate local hardness changes adjacent to the wear surface. DSRW samples generally did not exhibit significant work hardening. The austenitic materials exhibited significant hardening under the high impact conditions of the Bond abrasion wear test. Hardening in the Q&P materials was less pronounced. The Q&T microstructures also demonstrated some hardening. Scratch testing was performed on samples at three different loads, as a more systematic approach to determining the scratching abrasion behavior. Wear rates and scratch hardness were calculated from scratch testing results. Certain similarities between wear behavior in scratch testing
Polyimide film wear: Effect of temperature and atmosphere
NASA Technical Reports Server (NTRS)
Fusaro, R. L.
1976-01-01
Friction and wear experiments conducted on polyimide films bonded to 440C stainless steel disks indicated that a wear transition (from high wear to low wear) accompanied a friction transition (from high friction to low friction). In dry argon or dry air (less than 20 ppm H2O), the transition was found to occur at 40 plus or minus 10 C; when H20 was present in air (10,000 ppm H2O), the transition was found to be elevated to a temperature between 100 and 200 C. Wear rate calculations made at 25, 100, and 200 C indicated that film wear was relatively constant for particular experimental conditions; however, the rate was strongly dependent on temperature and atmosphere.
Puente Reyna, Ana Laura; Jäger, Marcus; Floerkemeier, Thilo; Frecher, Sven; Delank, Karl-Stefan; Schilling, Christoph; Grupp, Thomas M
2016-01-01
Backside wear due to micromotion and poor conformity between the liner and its titanium alloy shell may contribute to the high rates of retroacetabular osteolysis and consequent aseptic loosening. The purpose of our study was to understand the wear process on the backside of polyethylene liners from two acetabular cup systems, whose locking mechanism is based on a press-fit cone in combination with a rough titanium conical inner surface on the fixation area. A direct comparison between in vitro wear simulator tests (equivalent to 3 years of use) and retrieved liners (average 13.1 months in situ) was done in order to evaluate the backside wear characteristics and behavior of these systems. Similar wear scores between in vitro tested and retrieved liners were observed. The results showed that this locking mechanism did not significantly produce wear marks at the backside of the polyethylene liners due to micromotion. In all the analyzed liners, the most common wear modes observed were small scratches at the cranial fixation zone directly below the rough titanium inner surface of the shell. It was concluded that most of the wear marks were produced during the insertion and removal of the liner, rather than during its time in situ.
Helmet wearing in Kenya: prevalence, knowledge, attitude, practice and implications.
Bachani, A M; Hung, Y W; Mogere, S; Akunga, D; Nyamari, J; Hyder, A A
2017-03-01
In light of the increasing prevalence of motorcycles on Kenyan roads, there is a need to address the safety of individuals using this mode of transport. Helmet use has been proven to be effective in preventing head injuries and fatalities in the event of a crash. This study aims to understand the prevalence of helmet use as well as knowledge, attitudes, and practices in two districts in Kenya over a 5-year period (2010-2014). Observational studies on helmet use at randomly selected locations throughout each district were done every quarter to estimate the prevalence of helmet use. Roadside knowledge, attitude, and practice (KAP) surveys were done two times a year in each district. Helmet use among motorcycle drivers and passengers in Thika and Naivasha was assessed through systematic observations at randomly selected locations in the two districts between August 2010 and December 2014. Roadside KAP surveys were administered in both sites to motorcyclists in areas where they stopped, including motorcycle bays, petrol stations and rest areas near the helmet observation sites. Secondary analysis of trauma registries was also used. Negative binomial regressions were used to assess trends of helmet wearing among motorcyclists over time, and logistic regressions were used to analyze associated risk factors as well as association with health outcomes among those admitted to the four hospitals. A total of 256,851 motorcycles were observed in the two target districts during the study period. Overall, prevalence of helmet use among motorcycle drivers in Thika and Naivasha across all periods was 35.12% (95% confidence interval [CI]: 34.87%-35.38%) and 37.42% (95% CI: 37.15%-37.69%) respectively. Prevalence of helmet wearing remained similar after the passage of a traffic amendment bill. These results were not statistically significant in either Thika or in Naivasha. Data from the KAP survey showed that respondents recognized the life-saving effect of wearing a helmet, but
NASA Astrophysics Data System (ADS)
Kervalishvili, Guram; Lühr, Hermann
2014-05-01
We present climatology of the relationship of cusp-related density enhancement with the neutral zonal wind velocity, large-scale field-aligned current (FAC), small-scale FAC, and electron temperature using the superposed epoch analysis (SEA) method. The dependence of these variables on the interplanetary magnetic field (IMF) By component orientation and solar cycle are of particular interest. In addition, the obtained results of relative density enhancement (ρrel), zonal wind, electron temperature and FAC are subdivided into three local seasons of 130 days each: local winter (1 January ±65 days), combined equinoxes (1 April ±32 days and 1 October ±32 days), and local summer (1 July ±65 days). Our investigation is based on CHAMP satellite observations and NASA/GSFC's OMNI online data set for solar maximum (Mar/2002-2007) and minimum (Mar/2004-2009) conditions in the Northern Hemisphere. The SEA technique uses the time and location of the thermospheric mass density anomaly peaks as reference parameters. The relative amplitude of cusp-related density enhancement does on average not depend on the IMF By orientation, solar cycle phase, and local season. Also, it is apparent that the IMF By amplitude does not have a big influence on the relative amplitude of the density anomaly. Conversely, there exists a good correlation between ρrel and the negative amplitude of IMF Bz prevailing about half an hour earlier. In the cusp region, both large-scale FAC distribution and thermospheric zonal wind velocity exhibit a clear dependence on the IMF By orientation. In the case of positive (negative) IMF By there is a systematic imbalance between downward (upward) and upward (downward) FACs peaks equatorward and poleward of the reference point, respectively. The zonal wind velocity is directed towards west i.e. towards dawn in a geomagnetic latitude-magnetic local time (MLat-MLT) frame. This is true for all local seasons and solar conditions. The thermospheric density
The in vivo wear resistance of 12 composite resins.
Lang, B R; Bloem, T J; Powers, J M; Wang, R F
1992-09-01
The in vivo wear resistance of 12 composite resins were compared with an amalgam control using the Latin Square experimental design. Sixteen edentulous patients wearing specially designed complete dentures formed the experimental population. The Michigan Computer Graphics Measurement System was used to digitize the surface of the control and composite resin samples before and after 3-month test periods to obtain wear data. The 12 composite resins selected for this investigation based on their published composite classification types were seven fine particle composites, three blends, and two microfilled composite resins. The Latin Square experimental design was found to be valid with the factor of material being statistically different at the 5% level of significance. Wear was computed as volume loss (mm3/mm2), and all of the composites studied had more wear than the amalgam control (P = .001). After 3 months, the mean (error) of wear of the amalgam was 0.028 (0.006). Means (error) of wear for the 12 composites were ranked from most to least wear by mean wear volume loss. The absence of any relationship between mean wear volume loss and the volume percentage filler was confirmed by the correlation coefficient r = -0.158.
3D finite element modeling of sliding wear
NASA Astrophysics Data System (ADS)
Buentello Hernandez, Rodolfo G.
Wear is defined as "the removal of material volume through some mechanical process between two surfaces". There are many mechanical situations that can induce wear and each can involve many wear mechanisms. This research focuses on the mechanical wear due to dry sliding between two surfaces. Currently there is a need to identify and compare materials that would endure sliding wear under severe conditions such as high velocities. The high costs associated with the field experimentation of systems subject to high-speed sliding, has prevented the collection of the necessary data required to fully characterize this phenomena. Simulating wear through Finite Elements (FE) would enable its prediction under different scenarios and would reduce experimentation costs. In the aerospace, automotive and weapon industries such a model can aid in material selection, design and/or testing of systems subjected to wear in bearings, gears, brakes, gun barrels, slippers, locomotive wheels, or even rocket test tracks. The 3D wear model presented in this dissertation allows one to reasonably predict high-speed sliding mechanical wear between two materials. The model predictions are reasonable, when compared against those measured on a sled slipper traveling over the Holloman High Speed Tests Track. This slipper traveled a distance of 5,816 meters in 8.14 seconds and reached a maximum velocity of 1,530 m/s.
Wear and microhardness of different resin composite materials.
Say, Esra Can; Civelek, Arzu; Nobecourt, Alain; Ersoy, Mustafa; Guleryuz, Canan
2003-01-01
This study determined the three-body abrasive wear resistance of two packable composites (P-60; Solitaire 2), an ion-releasing composite (Ariston AT), a hybrid composite (Tetric Ceram) and an ormocer (Admira). The study also looked at the correlation between wear resistance and hardness of the composites. Three-body wear testing was performed using an ACTA wear machine with 15 N contact force using millet seed as the third body. Wear depth (microm) was measured by profilometry after 200,000 cycles. The hardness test was performed using a digital microhardness tester (load: 500 g; dwell time: 15 seconds). The data were analyzed by using Kruskal Wallis (p < 0.05). There were statistically significant differences among the three body abrasive wear of the composites. The ranking from least to most were as follows: Filtek P-60 < Solitaire 2 < Ariston AT < Tetric Ceram < Admira. Filtek P-60 showed the highest microhardness value. No other significant differences in hardness were observed among the different resin composites (P-60 > AristonAT = Tetric Ceram = Solitaire 2 = Admira). The results of this study indicate that there are significant differences in the wear resistance of the resin composites. The correlation between hardness and wear was significant with a correlation coefficient of r:-0.91. A significant negative correlation exists between hardness and three-body wear of resin composites.
Wear behavior of pressable lithium disilicate glass ceramic.
Peng, Zhongxiao; Izzat Abdul Rahman, Muhammad; Zhang, Yu; Yin, Ling
2016-07-01
This article reports effects of surface preparation and contact loads on abrasive wear properties of highly aesthetic and high-strength pressable lithium disilicate glass-ceramics (LDGC). Abrasive wear testing was performed using a pin-on-disk device in which LDGC disks prepared with different surface finishes were against alumina pins at different contact loads. Coefficients of friction and wear volumes were measured as functions of initial surface finishes and contact loads. Wear-induced surface morphology changes in both LDGC disks and alumina pins were characterized using three-dimensional laser scanning microscopy, scanning electron microscopy, and energy dispersive X-ray spectroscopy. The results show that initial surface finishes of LDGC specimens and contact loads significantly affected the friction coefficients, wear volumes and wear-induced surface roughness changes of the material. Both wear volumes and friction coefficients of LDGC increased as the load increased while surface roughness effects were complicated. For rough LDGC surfaces, three-body wear was dominant while for fine LDGC surfaces, two-body abrasive wear played a key role. Delamination, plastic deformation, and brittle fracture were observed on worn LDGC surfaces. The adhesion of LDGC matrix materials to alumina pins was also discovered. This research has advanced our understanding of the abrasive wear behavior of LDGC and will provide guidelines for better utilization and preparation of the material for long-term success in dental restorations. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 104B: 968-978, 2016. © 2015 Wiley Periodicals, Inc.
Wear of human enamel: a quantitative in vitro assessment.
Kaidonis, J A; Richards, L C; Townsend, G C; Tansley, G D
1998-12-01
Many factors influence the extent and rate at which enamel wears. Clinical studies in humans are limited by difficulties in the accurate quantification of intra-oral wear and by a lack of control over the oral environment. The purpose of this study was to determine the wear characteristics of human dental enamel under controlled experimental conditions. An electro-mechanical tooth wear machine, in which opposing enamel surfaces of sectioned, extracted teeth were worn under various conditions, was used to simulate tooth grinding or bruxism. Enamel surface wear was quantified by weight to an accuracy of 0.1 mg, with water uptake and loss controlled. The variables considered included the structure and hardness of enamel, facet area, duration of tooth contact, relative speed of opposing surfaces, temperature, load, pH, and the nature of the lubricant. Enamel wear under non-lubricated conditions increased with increasing load over the range of 1.7 to 16.2 kg. The addition of a liquid lubricant (pH = 7) reduced enamel wear up to 6.7 kg, but when the load increased above this threshold, the rate of wear increased dramatically. With the viscosity of the lubricant constant and pH = 3, the rate of wear was further reduced to less than 10% of the non-lubricated rate at 9.95 kg, after which the rate again increased substantially. Under more extreme conditions (pH = 1.2, simulating gastric acids), the wear was excessive under all experimental loads. When saliva was used as a lubricant, the amount of wear was relatively low at 9.95 kg, but rapid wear occurred at 14.2 kg and above. These results indicate that under non-lubricated conditions, enamel wear remains low at high loads due to the dry-lubricating capabilities of fine enamel powder. Under lubricated conditions, low loads with an acidic lubricant lead to little enamel wear, whereas very low pH results in a high rate of wear under all loads.
Localized wear of compomer restorative materials.
Latta, M A; Barkmeier, W W; Wilwerding, T M; Blake, S M
2001-08-01
To determine and compare the localized wear of six compomer restorative materials. Ten specimens of Dyract, Dyract AP, F2000, Compoglass F, Elan and Hytac were prepared in a custom fixture and polished. A pretest surface profile was generated using an MTS 3-D surface profilometer and the specimens were subjected to 400,000 cycles in a Leinfelder wear machine equipped with a conical stylus tip to simulate localized wear. A post-test profile was generated and the before and after profiles were fitted and analyzed using AnSur 3-D software. The total volume loss and depth of the wear facet on each specimen was calculated and statistical analysis was accomplished (ANOVA and Tukey's test). Volume loss (mm3) was as follows: F2000, 0.027 +/- 0.002; Hytac, 0.007 +/- 0.023; Elan, 0.054 +/- 0.013; Compoglass F, 0.135 +/- 0.006; Dyract AP, 0.135 +/- 0.023; Dyract, 0.185 +/- 0.032. Maximum depth of the wear facets (microm) was as follows: F2000, 112.2 +/- 10.2; Hytac, 132.8 +/- 9.3; Elan, 144.3 +/- 23. 1; Compoglass F, 168.3 +/- 13.0; Dyract AP, 194.0 +/- 19.7; Dyract, 220.6 +/- 15.8. There was not a difference (P > 0.05) in volumetric loss between F2000 and Hytac or between Hytac and Elan. The volume loss and maximum depth of the wear facets of F2000, Hytac and Elan was significantly less (P< 0.05) than Compoglass F, Dyract AP and Dyract The results of this study indicate that there are significant differences in the in vitro wear rates of compomer materials.
Comparative wear resistance of reinforced glass ionomer restorative materials.
Yap, A U; Teo, J C; Teoh, S H
2001-01-01
This study investigated the wear resistance of three restorative reinforced glass ionomer cements (Fuji IX GP FAST [FJ], Miracle Mix [MM] and Ketac Silver [KS]). Microfilled (Silux [SX]) and mini-filled (Z100 [ZO]) composites were used for comparison. Six specimens were made for each material. The specimens were conditioned for one week in distilled water at 37 degrees C and subjected to wear testing at 20 MPa contact stress against SS304 counterbodies using a reciprocal compression-sliding wear instrumentation. Distilled water was used as lubricant. Wear depth (microm) was measured using profilometry every 2,000 cycles up to 10,000 cycles. Results were analyzed using ANOVA/Scheffe's test (p<0.05). After 10,000 cycles of wear testing, ranking was as follows: KS>ZO>MM>FJ>SX. Wear ranged from 26.1 microm for SX to 71.5 microm for KS. The wear resistance of KS was significantly lower than FJ, MM and SX at all wear intervals. Although KS had significantly more wear than ZO at 2,000 to 6,000 cycles, no significant difference in wear was observed between these two materials at 8,000 and 10,000 cycles. Sintering of silver particles to glass ionomer cement (KS) did not appear to improve wear resistance. The simple addition of amalgam alloy to glass ionomer may improve wear resistance but results in poor aesthetics (silver-black color). FJ, which relies on improved chemistry instead of metal fillers, showed comparable wear resistance to the composites evaluated and is tooth-colored. It may serve as a potential substitute for composites in low-stress situations where fluoride release is desirable and aesthetic requirements are not high.
The lexicon of polyethylene wear in artificial joints.
McKellop, Harry A
2007-12-01
The analysis of wear on polyethylene components that have been retrieved after use in patients has provided invaluable understanding of how wear occurs in vivo, and how it may be minimized through improved materials and implant design. The great number of such studies that have been published over the past three decades has lead to an extensive vocabulary to describe the tribology of prosthetic joints. However, these also have led to some confusion, due to the occasional misuse of terms from classical tribology, along with the use of multiple terms to describe the same wear phenomenon, and vice versa. The author has proposed that our understanding of wear in artificial joints may be enhanced by recognizing that there are four general subject areas: Modes, Mechanisms, Damage and Debris. Wear Mode 1 occurs when the two bearing surfaces are articulating against each other in the manner intended by the implant designer. Mode 2 occurs when a bearing surface articulates against a non-bearing surface. Mode 3 occurs when third-body abrasive particles have become entrapped between the two bearing surfaces, and Mode 4 occurs when two non-bearing surfaces are wearing against each other. The least wear occurs in Mode 1, whereas severe wear typically occurs in Modes 2, 3 and 4. The classical wear mechanisms that apply to prosthetic joints include adhesion, abrasion and fatigue. These can occur in varying amounts in either of the four wear modes. As used in the literature for the past three decades, wear "damage" can best be defined as the change surface texture or morphology that is caused by the action of the wear mechanisms. Although a wide variety of terms have been used, an overview of the literature indicates that about eight terms have been sufficient to describe the types of damage that occur on retrieved polyethylene components, i.e., burnishing, abrasion, scratches, plastic deformation, cracks, pits, delamination, and embedded third bodies. The author suggests that, as
Localized and generalized simulated wear of resin composites.
Barkmeier, W W; Takamizawa, T; Erickson, R L; Tsujimoto, A; Latta, M; Miyazaki, M
2015-01-01
A laboratory study was conducted to examine the wear of resin composite materials using both a localized and generalized wear simulation model. Twenty specimens each of seven resin composites (Esthet•X HD [HD], Filtek Supreme Ultra [SU], Herculite Ultra [HU], SonicFill [SF], Tetric EvoCeram Bulk Fill [TB], Venus Diamond [VD], and Z100 Restorative [Z]) were subjected to a wear challenge of 400,000 cycles for both localized and generalized wear in a Leinfelder-Suzuki wear simulator (Alabama machine). The materials were placed in custom cylinder-shaped stainless steel fixtures. A stainless steel ball bearing (r=2.387 mm) was used as the antagonist for localized wear, and a stainless steel, cylindrical antagonist with a flat tip was used for generalized wear. A water slurry of polymethylmethacrylate (PMMA) beads was used as the abrasive media. A noncontact profilometer (Proscan 2100) with Proscan software was used to digitize the surface contours of the pretest and posttest specimens. AnSur 3D software was used for wear assessment. For localized testing, maximum facet depth (μm) and volume loss (mm(3)) were used to compare the materials. The mean depth of the facet surface (μm) and volume loss (mm(3)) were used for comparison of the generalized wear specimens. A one-way analysis of variance (ANOVA) and Tukey post hoc test were used for data analysis of volume loss for both localized and generalized wear, maximum facet depth for localized wear, and mean depth of the facet for generalized wear. The results for localized wear simulation were as follows [mean (standard deviation)]: maximum facet depth (μm)--Z, 59.5 (14.7); HU, 99.3 (16.3); SU, 102.8 (13.8); HD, 110.2 (13.3); VD, 114.0 (10.3); TB, 125.5 (12.1); SF, 195.9 (16.9); volume loss (mm(3))--Z, 0.013 (0.002); SU, 0.026 (0.006); HU, 0.043 (0.008); VD, 0.057 (0.009); HD, 0.058 (0.014); TB, 0.061 (0.010); SF, 0.135 (0.024). Generalized wear simulation results were as follows: mean depth of facet (μm)--Z, 9.3 (3
Magbanua, Mark Jesus M; Park, John W
2013-12-01
Circulating tumor cells (CTCs) are cells shed by the primary tumor into the blood stream capable of initiating distant metastasis. In the past decade, numerous assays have been developed to reliably detect these extremely rare cells. However, methods for purification of CTCs with little or no contamination of normal blood cells for molecular profiling are limited. We have developed a novel protocol to isolate CTCs by combining immunomagnetic enrichment and fluorescence-activated cell sorting (IE/FACS). The two-part assay includes (1) immunomagnetic capture using magnetic beads conjugated to monoclonal antibody against an epithelial cell adhesion marker (EpCAM) to enrich for tumor cells; and (2) FACS analysis using EpCAM to purify tumor cells away from mononuclear cells of hematopoietic lineage. Downstream molecular analyses of single and pooled cells confirmed the isolation of highly pure CTCs with characteristics typical that of malignant cells. Copyright © 2013 Elsevier Inc. All rights reserved.
Friction and wear behaviors of MoS2/Zr coated HSS in sliding wear and in drilling processes
NASA Astrophysics Data System (ADS)
Deng, Jianxin; Yan, Pei; Wu, Ze
2012-11-01
MoS2 metal composite coatings have been successful used in dry turning, but its suitability for dry drilling has not been yet established. Therefore, it is necessary to study the friction and wear behaviors of MoS2/Zr coated HSS in sliding wear and in drilling processes. In the present study, MoS2/Zr composite coatings are deposited on the surface of W6Mo5Cr4V2 high speed steel(HSS). Microstructural and fundamental properties of these coatings are examined. Ball-on-disc sliding wear tests on the coated discs are carried out, and the drilling performance of the coated drills is tested. Test results show that the MoS2/Zr composite coatings exhibit decreases friction coefficient to that of the uncoated HSS in sliding wear tests. Energy dispersive X-ray(EDX) analysis on the wear surface indicates that there is a transfer layer formed on the counterpart ball during sliding wear processes, which contributes to the decreasing of the friction coefficient between the sliding couple. Drilling tests indicate that the MoS2/Zr coated drills show better cutting performance compared to the uncoated HSS drills, coating delamination and abrasive are found to be the main flank and rake wear mode of the coated drills. The proposed research founds the base of the application of MoS2 metal composite coatings on dry drilling.
Tome-Garcia, Jessica; Doetsch, Fiona; Tsankova, Nadejda M.
2018-01-01
Direct isolation of human neural and glioma stem cells from fresh tissues permits their biological study without prior culture and may capture novel aspects of their molecular phenotype in their native state. Recently, we demonstrated the ability to prospectively isolate stem cell populations from fresh human germinal matrix and glioblastoma samples, exploiting the ability of cells to bind the Epidermal Growth Factor (EGF) ligand in fluorescence-activated cell sorting (FACS). We demonstrated that FACS-isolated EGF-bound neural and glioblastoma populations encompass the sphere-forming colonies in vitro, and are capable of both self-renewal and multilineage differentiation. Here we describe in detail the purification methodology of EGF-bound (i.e., EGFR+) human neural and glioma cells with stem cell properties from fresh postmortem and surgical tissues. The ability to prospectively isolate stem cell populations using native ligand-binding ability opens new doors for understanding both normal and tumor cell biology in uncultured conditions, and is applicable for various downstream molecular sequencing studies at both population and single-cell resolution. PMID:29516026
Abhayawardhana, Pramuditha L; Marzilli, Patricia A; Fronczek, Frank R; Marzilli, Luigi G
2014-01-21
Tertiary sulfonamide nitrogen-to-metal bonds of normal length are very rare. We recently discovered such a bond in one class of fac-[Re(CO)3(N(SO2R)(CH2Z)2)](n) complexes (Z = 2-pyridyl) with N(SO2R)dpa ligands derived from di-(2-picolyl)amine (N(H)dpa). fac-[M(CO)3(N(SO2R)(CH2Z)2)](n) agents (M = (186/188)Re, (99m)Tc) could find use as radiopharmaceutical bioconjugates when R is a targeting moiety. However, the planar, electron-withdrawing 2-pyridyl groups of N(SO2R)dpa destabilize the ligand to base and create relatively rigid chelate rings, raising the possibility that the rare M-N(sulfonamide) bond is an artifact of a restricted geometry. Also, the hydrophobic 2-pyridyl groups could cause undesirable accumulation in the liver, limiting future use in radiopharmaceuticals. Our goal is to identify a robust, hydrophilic, and flexible N(CH2Z)2 chelate framework. New C2-symmetric ligands, N(SO2R)(CH2Z)2 with (Z = CH2NH2; R = Me, dmb, or tol), were prepared by treating N(H)dien(Boc)2, a protected diethylenetriamine (N(H)dien) derivative, with methanesulfonyl chloride (MeSO2Cl), 3,5-dimethylbenzenesulfonyl chloride (dmbSO2Cl), and 4-methylbenzenesulfonyl chloride (tolSO2Cl). Treatment of fac-[Re(CO)3(H2O)3](+) with these ligands, designated as N(SO2R)dien, afforded new fac-[Re(CO)3(N(SO2R)dien)]PF6 complexes. Comparing the fac-[Re(CO)3(N(SO2Me)dien)]PF6 and fac-[Re(CO)3(N(SO2Me)dpa)]PF6 complexes, we find that the Re(I)-N(sulfonamide) bonds are normal in length and statistically identical and that the methyl (13)C NMR signal has an unusually upfield shift compared to that in the free ligand. We attribute this unusual upfield shift to the fact that the sulfonamide N undergoes an sp(2)-to-sp(3) rehybridization upon coordination to Re(I) in both complexes. Thus, the sulfonamide N of N(SO2R)dien ligands is a good donor, even though the chelate rings are conformationally flexible. Addition of the strongly basic and potentially monodentate ligand, 4-dimethylaminopyridine
Anti-wear Mechanism Analysis of Nano-CaCO3 Additives
NASA Astrophysics Data System (ADS)
Xu, Zhen; Sun, Junfeng
2018-06-01
In this paper, the wear test was carried on with cylinder piston by the wear test device, receiving the results of the piston ring wear and abrasive characteristics by monitoring the wear process, the thesis analysis and put forward the nano-CaCO3 lubricating oil additive anti wear mechanism by the ferrography analysis technology, and provide the technical reference for the relevant measures to reduce wear and the friction, and provide reference value for further study on the related theories of reducing wear and reducing friction.
Friction and wear of nickel in sulfuric acid
NASA Technical Reports Server (NTRS)
Rengstorff, G. W. P.; Miyoshi, K.; Buckley, D. H.
1984-01-01
Experiments were conducted with elemental nickel sliding on aluminum oxide in aerated sulfuric acid in concentrations ranging from very dilute (10 -4 N, i.e., 5 ppm) to very concentrated (96 percent) acid. Load and reciprocating sliding speeds were kept constant. With the most dilute concentration (10 -4 N) no observable corrosion occurred in or outside the wear area. This was used as the base condition to determine the high contribution of corrosion to total wear loss at acid concentrations between 0.5 percent (0.1 N) and 75 percent. Corrosion reached a maximum rate of 100 millimeters per year at 30 percent acid. At the same time, general corrosion outside the wear area was very low, in agreement with published information. It is clear that friction and wear greatly accelerated corrosion in the wear area. At dilute concentrations of 0.001 and 0.01 N, corrosion in the wear area was low, and general corrosion outside was also low, but local outside regions in the direction of the wear motion experienced some enhanced corrosion, apparently due to fluid motion of the acid.
A Low-Wear Driving Method of Ultrasonic Motors
NASA Astrophysics Data System (ADS)
Ishii, Takaaki; Takahashi, Hisanori; KentaroNakamura, KentaroNakamura; Ueha, Sadayuki
1999-05-01
The life of ultrasonic motors is limited by the wear of friction materials used for the contact surfaces. In order to reduce the wear of the friction material, we have to reduce the sliding speed between the sliding surfaces of the motor. In this report, we propose a new driving method to reduce the sliding speed of the motor by shaping the vibration speed waveform. The sliding loss was calculated and wear reduction effect was confirmed. A wear test was carried out under no-load condition. This method prolongs the life of an ultrasonic motor by about 3.4-fold. The results and wear reduction effects are also described.
Finger wear detection for production line battery tester
Depiante, Eduardo V.
1997-01-01
A method for detecting wear in a battery tester probe. The method includes providing a battery tester unit having at least one tester finger, generating a tester signal using the tester fingers and battery tester unit with the signal characteristic of the electrochemical condition of the battery and the tester finger, applying wavelet transformation to the tester signal including computing a mother wavelet to produce finger wear indicator signals, analyzing the signals to create a finger wear index, comparing the wear index for the tester finger with the index for a new tester finger and generating a tester finger signal change signal to indicate achieving a threshold wear change.
3D FEM Simulation of Flank Wear in Turning
NASA Astrophysics Data System (ADS)
Attanasio, Aldo; Ceretti, Elisabetta; Giardini, Claudio
2011-05-01
This work deals with tool wear simulation. Studying the influence of tool wear on tool life, tool substitution policy and influence on final part quality, surface integrity, cutting forces and power consumption it is important to reduce the global process costs. Adhesion, abrasion, erosion, diffusion, corrosion and fracture are some of the phenomena responsible of the tool wear depending on the selected cutting parameters: cutting velocity, feed rate, depth of cut, …. In some cases these wear mechanisms are described by analytical models as a function of process variables (temperature, pressure and sliding velocity along the cutting surface). These analytical models are suitable to be implemented in FEM codes and they can be utilized to simulate the tool wear. In the present paper a commercial 3D FEM software has been customized to simulate the tool wear during turning operations when cutting AISI 1045 carbon steel with uncoated tungsten carbide tip. The FEM software was improved by means of a suitable subroutine able to modify the tool geometry on the basis of the estimated tool wear as the simulation goes on. Since for the considered couple of tool-workpiece material the main phenomena generating wear are the abrasive and the diffusive ones, the tool wear model implemented into the subroutine was obtained as combination between the Usui's and the Takeyama and Murata's models. A comparison between experimental and simulated flank tool wear curves is reported demonstrating that it is possible to simulate the tool wear development.
NASA Astrophysics Data System (ADS)
Megan Gillies, D.; Knudsen, D.; Donovan, E.; Jackel, B.; Gillies, R.; Spanswick, E.
2017-08-01
We present a comprehensive survey of 630 nm (red-line) emission discrete auroral arcs using the newly deployed Redline Emission Geospace Observatory. In this study we discuss the need for observations of 630 nm aurora and issues with the large-altitude range of the red-line aurora. We compare field-aligned currents (FACs) measured by the Swarm constellation of satellites with the location of 10 red-line (630 nm) auroral arcs observed by all-sky imagers (ASIs) and find that a characteristic emission height of 200 km applied to the ASI maps gives optimal agreement between the two observations. We also compare the new FAC method against the traditional triangulation method using pairs of all-sky imagers (ASIs), and against electron density profiles obtained from the Resolute Bay Incoherent Scatter Radar-Canadian radar, both of which are consistent with a characteristic emission height of 200 km.
Brush seal shaft wear resistant coatings
NASA Astrophysics Data System (ADS)
Howe, Harold
1995-03-01
Brush seals suffer from high wear, which reduces their effectiveness. This work sought to reduce brush seal wear by identifying and testing several industry standard coatings. One of the coatings was developed for this work. It was a co-sprayed PSZ with boron-nitride added for a high temperature dry lubricant. Other coatings tested were a PSZ, chrome carbide and a bare rotor. Testing of these coatings included thermal shocking, tensile testing and wear/coefficient of friction testing. Wear testing consisted of applying a coating to a rotor and then running a sample tuft of SiC ceramic fiber against the coating. Surface speeds at point of contact were slightly over 1000 ft/sec. Rotor wear was noted, as well as coefficient of friction data. Results from the testing indicates that the oxide ceramic coatings cannot withstand the given set of conditions. Carbide coatings will not work because of the need for a metallic binder, which oxidizes in the high heat produced by friction. All work indicated a need for a coating that has a lubricant contained within itself and the coating must be resistant to an oxidizing environment.
Magnetic Fluid Friction and Wear Behavior
NASA Technical Reports Server (NTRS)
Keith, Theo G., Jr.
1998-01-01
The friction and wear properties of two groups of magnetic fluids, one developed at NASA Lewis Research Center and a commercial fluid, were evaluated for boundary lubrication. Friction and wear measurements were made using a pin-on-disk apparatus. Three different ball materials were evaluated, (1) 440C, (2) Al2O3, and (3) Si3N4 against 440C disks. The first class of magnetic fluids have a low vapor pressure hydrocarbon base oil and are suitable for space application. Four variations of this fluid were evaluated: (1) the base oil, (2) base oil with anti-wear additives, (3) a 100 Gauss strength magnetic fluid, and (4) a 400 gauss magnetic fluid. The commercial fluid base oil and four different magnetic particle concentration levels have been evaluated. A space qualified fluorinated lubricant was tested for base line comparison. Hardness, optical microscopy, surface profilometry, and surface analysis were used to characterize the test specimens. Friction was unaffected by the concentration of magnetic particles. Wear rates for magnetic fluids were slightly higher than the base oil. The low vapor pressure magnetic fluid has better wear characteristics than the space qualified fluorinated lubricant.
Abrasive wear of Hilong BoTN hardfacings
NASA Astrophysics Data System (ADS)
Fedorova, L.; Fedorov, S.; Sadovnikov, A.; Ivanova, Y.; Voronina, M.
2018-02-01
The spread of steels, which are used to produce locks of steel drill pipes, adversely affects their wear resistance, which, in combination with low hardness of HV 2400 ... 2800 MPa as well as of the thread of screw, results in low wear resistance and the need for their reconstruction at the pipe control shop. An efficient way of improving the quality of drill pipe jonts is to hard-face them by the outside diameter with wear-resistant materials (hardbanding). One of the companies engaged in the development of hardfacing materials and hardbanding is Hilong (China) with weld seams of the brand BoTn. According to the results of the studies the following conclusion can be made: hardfacing increases the durability of the hardware, contributing to an increase in wear resistance of locks of DP under the conditions of abrasive action of aggressive geological formations; the usage of DP without wear-resistant weld seams is impermissible, because their further operation, as part of the drill-stem, can lead to emergency consequences; application of the pipes with the hardfacing collars together with the collars without hardfacing, due to varying degree of wear of jonts in the drill-stem, is also impermissible.
Assessment of variations in wear test methodology.
Gouvêa, Cresus V D; Weig, Karin; Filho, Thales R M; Barros, Renata N
2010-01-01
The properties of composite resin for dental fillings were improved by development, but its weakness continues to be its wear strength. Several tests have been proposed to evaluate wear in composite resin materials. The aim of this study was to verify how polishing and the type of abrasive can influence the wear rate of composite resin. The test was carried out on two groups. In one group we employed an ormocer and a hybrid composite that was polished group the composite was polished with the same abrasive paper plus a 1 microm and 0.25 microm grit diamond paste. A three-body wear test was performed using the metal sphere of the wear test machine, the composite and an abrasive. A diamond paste and aluminum oxide dispersion were used as abrasive. Analysis of the results showed that there was no difference between polishing techniques, but revealed a difference between abrasives.
Biologically Based Restorative Management of Tooth Wear
Kelleher, Martin G. D.; Bomfim, Deborah I.; Austin, Rupert S.
2012-01-01
The prevalence and severity of tooth wear is increasing in industrialised nations. Yet, there is no high-level evidence to support or refute any therapeutic intervention. In the absence of such evidence, many currently prevailing management strategies for tooth wear may be failing in their duty of care to first and foremost improve the oral health of patients with this disease. This paper promotes biologically sound approaches to the management of tooth wear on the basis of current best evidence of the aetiology and clinical features of this disease. The relative risks and benefits of the varying approaches to managing tooth wear are discussed with reference to long-term follow-up studies. Using reference to ethical standards such as “The Daughter Test”, this paper presents case reports of patients with moderate-to-severe levels of tooth wear managed in line with these biologically sound principles. PMID:22315608
Perera, Theshini; Fronczek, Frank R; Marzilli, Patricia A; Marzilli, Luigi G
2010-08-02
Addition of various RNH(2) to fac-[Re(CO)(3)(5,5'-Me(2)bipy)(CH(3)CN)]BF(4) (1) converts the acetonitrile ligand to the amidine ligand (a superbase) in fac-[Re(CO)(3)(5,5'-Me(2)bipy)(HNC(CH(3))NHR)]BF(4) products. Each complex has four conceivable isomers (E, E', Z, and Z') because the amidine CN bonds have double-bond character, and the two remote NHR group substituents are different. The reaction of 1 in acetonitrile is complete in 6 to 96 h (25 degrees C) and forms fac-[Re(CO)(3)(5,5'-Me(2)bipy)(HNC(CH(3))NHR)]BF(4) E' and Z isomers. Only the E' isomer formed crystals (R = methyl, isopropyl, isobutyl, tert-butyl, and benzyl). Upon dissolution of such crystals in acetonitrile-d(3), NMR spectra with highly dominant E' signals gradually changed (approximately 15 min at room temperature) to spectra with signals for an equilibrium mixture of E' and Z isomers. Such slow E'-to-Z isomer interchange is also indicated by 2D ROESY NMR data used primarily to assign solution structure. Equilibrium ratios (E':Z) of approximately 65:35 for R = methyl, isopropyl, and isobutyl and 83:17 for R = tert-butyl demonstrate that increasing the remote NHR group steric bulk above a threshold size favors the E' isomer. Consistent with this trend, fac-[Re(CO)(3)(5,5'-Me(2)bipy)(HNC(CH(3))NH(2))]BF(4), with a remote NH(2) (low bulk) group, favors the Z isomer. In contrast, although the remote NH(benzyl) group in fac-[Re(CO)(3)(5,5'-Me(2)bipy)(HNC(CH(3))NH(CH(2)C(6)H(5))]BF(4) has only moderate bulk, the E' isomer has high abundance as a result of favorable 5,5'-Me(2)bipy/benzyl stacking, evidence for which is present in both solid and solution states. The fac-[Re(CO)(3)(5,5'-Me(2)bipy)(HNC(CH(3))NHR)]BF(4) E isomer can be detected in solvents of low polarity. However, the Z' isomer was not observed, undoubtedly because unfavorable remote-group clashes with the equatorial ligands destabilize this isomer. Challenge studies with a 5-fold excess of 4-dimethylaminopyridine in acetonitrile-d(3
The effect of microstructure on abrasive wear of steel
NASA Astrophysics Data System (ADS)
Kešner, A.; Chotëborský, R.; Linda, M.
2017-09-01
Abrasive wear of agricultural tools is one of the biggest problems in currently being. The amount of abrasive wear, depending on the microstructure, has been investigated in this work. Steels 25CrMo4 and 51CrV4 were used in this work to determine the effect of the microstructure on the abrasive wear. These steels are commonly used for components that have to withstand abrasive wear.SEM analysis was used to detect the microstructure. The standardized ASTM G65 method was used to compare the abrasive wear of steels. The results show that the abrasive wear depends on the microstructure of steels.
Diagnostics of wear in aeronautical systems
NASA Technical Reports Server (NTRS)
Wedeven, L. D.
1979-01-01
Maintenance costs associated with the transmissions and drive train greatly increase the maintenance burden and failure risk. Detection measurements fall under two general categories of vibration and particle detectors. The latter are more amenable to tracking wear. Wear debris analysis can supply a great deal of information such as: particle concentration, rate of change in concentration, composition, particle size and shape, principal metals, etc. It is not economically feasible to monitor all variables. At least one role of the lubrication and wear specialist is to provide guidance in selecting the most appropriate variables to monitor.
19 CFR 10.35 - Models of women's wearing apparel.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 19 Customs Duties 1 2010-04-01 2010-04-01 false Models of women's wearing apparel. 10.35 Section... Temporary Importations Under Bond § 10.35 Models of women's wearing apparel. (a) Models of women's wearing... the importer or his employees. (b) Invoices covering models of women's wearing apparel entered under...
Ceramic-like wear behaviour of human dental enamel.
Arsecularatne, J A; Hoffman, M
2012-04-01
This paper reports a transmission electron microscopy (TEM) analysis of subsurfaces of enamel specimens following in vitro reciprocating wear tests with an enamel cusp sliding on a flat enamel specimen under hydrated conditions. The obtained results show that crack formation occurred in the wear scar subsurface. The path followed by these cracks seems to be dictated either by the histological structure of enamel or by the contact stress field. Moreover, the analysis of a set of enamel wear results obtained from the literature and application of fracture-based models, originally developed for ceramics, correlate well, confirming the similar wear processes taking place in these materials. This analysis also reveals a marked influence of coefficient of friction on the enamel wear rate: for a higher coefficient of friction value, enamel wear can be severe even under forces generated during normal operation of teeth. Copyright © 2011 Elsevier Ltd. All rights reserved.
Say, Emil Anthony T; Melamud, Alex; Esserman, Denise Ann; Povsic, Thomas J; Chavala, Sai H
2013-01-01
Patients with age-related macular degeneration (ARMD) begin with non-neovascular (NNV) phenotypes usually associated with good vision. Approximately 20% of NNV-ARMD patients will convert to vision debilitating neovascular (NV) ARMD, but precise timing of this event is unknown. Developing a clinical test predicting impending conversion to NV-ARMD is necessary to prevent vision loss. Endothelial progenitor cells (EPCs), defined as CD34(+)VEGR2(+) using traditional fluorescence activated cell sorting (FACS), are rare cell populations known to be elevated in patients with NV-ARMD compared to NNV-ARMD. FACS has high inter-observer variability and subjectivity when measuring rare cell populations precluding development into a diagnostic test. We hypothesized that automated rare cell analysis (ARCA), a validated and FDA-approved technology for reproducible rare cell identification, can enumerate EPCs in ARMD patients more reliably. This pilot study serves as the first step in developing methods for reproducibly predicting ARMD phenotype conversion. We obtained peripheral venous blood samples in 23 subjects with NNV-ARMD or treatment naïve NV-ARMD. Strict criteria were used to exclude subjects with known angiogenic diseases to minimize confounding results. Blood samples were analyzed in masked fashion in two separate laboratories. EPCs were independently enumerated using ARCA and FACS within 24 hours of blood sample collection, and p<0.2 was considered indicative of a trend for this proof of concept study, while statistical significance was established at 0.05. We measured levels of CD34(+)VEGFR2(+) EPCs suggestive of a trend with higher values in patients with NV compared to NNV-ARMD (p = 0.17) using ARCA. Interestingly, CD34(+)VEGR2(+) EPC analysis using FACS did not produce similar results (p = 0.94). CD34(+)VEGR2(+) may have predictive value for EPC enumeration in future ARCA studies. EPC measurements in a small sample size were suggestive of a trend in ARMD using
Say, Emil Anthony T.; Melamud, Alex; Esserman, Denise Ann; Povsic, Thomas J.; Chavala, Sai H.
2013-01-01
Background Patients with age-related macular degeneration (ARMD) begin with non-neovascular (NNV) phenotypes usually associated with good vision. Approximately 20% of NNV-ARMD patients will convert to vision debilitating neovascular (NV) ARMD, but precise timing of this event is unknown. Developing a clinical test predicting impending conversion to NV-ARMD is necessary to prevent vision loss. Endothelial progenitor cells (EPCs), defined as CD34+VEGR2+ using traditional fluorescence activated cell sorting (FACS), are rare cell populations known to be elevated in patients with NV-ARMD compared to NNV-ARMD. FACS has high inter-observer variability and subjectivity when measuring rare cell populations precluding development into a diagnostic test. We hypothesized that automated rare cell analysis (ARCA), a validated and FDA-approved technology for reproducible rare cell identification, can enumerate EPCs in ARMD patients more reliably. This pilot study serves as the first step in developing methods for reproducibly predicting ARMD phenotype conversion. Methods We obtained peripheral venous blood samples in 23 subjects with NNV-ARMD or treatment naïve NV-ARMD. Strict criteria were used to exclude subjects with known angiogenic diseases to minimize confounding results. Blood samples were analyzed in masked fashion in two separate laboratories. EPCs were independently enumerated using ARCA and FACS within 24 hours of blood sample collection, and p<0.2 was considered indicative of a trend for this proof of concept study, while statistical significance was established at 0.05. Results We measured levels of CD34+VEGFR2+ EPCs suggestive of a trend with higher values in patients with NV compared to NNV-ARMD (p = 0.17) using ARCA. Interestingly, CD34+VEGR2+ EPC analysis using FACS did not produce similar results (p = 0.94). Conclusions CD34+VEGR2+ may have predictive value for EPC enumeration in future ARCA studies. EPC measurements in a small sample size were
[Influence of multiple sintering on wear behavior of Cercon veneering ceramic].
Gao, Qing-ping; Chao, Yong-lie; Jian, Xin-chun; Guo, Feng
2010-04-01
To investigate the influence of multiple sintering on wear behavior of Cercon veneering ceramic. Samples were fabricated according to the manufacture's requirement for different sintering times (1, 3, 5, 7 times). The wear test was operated with a modified MM-200 friction and wear machine in vitro. The wear scars were characterized by scanning electron microscope (SEM) and atomic force microscopy (AFM). With the sintering times increasing, the wear scar width became larger. The correlation was significant at the 0.01 level. Significant difference was observed in wear scar width among different samples (P < 0.05). SEM and AFM results showed that veneering ceramic wear facets demonstrated grooves characteristic of abrasive wear. Multiple sintering can decrease the wear ability of Cercon veneer, and the wear pattern has the tendency to severe wear.
Finger wear detection for production line battery tester
Depiante, E.V.
1997-11-18
A method is described for detecting wear in a battery tester probe. The method includes providing a battery tester unit having at least one tester finger, generating a tester signal using the tester fingers and battery tester unit with the signal characteristic of the electrochemical condition of the battery and the tester finger, applying wavelet transformation to the tester signal including computing a mother wavelet to produce finger wear indicator signals, analyzing the signals to create a finger wear index, comparing the wear index for the tester finger with the index for a new tester finger and generating a tester finger signal change signal to indicate achieving a threshold wear change. 9 figs.
Nanoscale wear as a stress-assisted chemical reaction
NASA Astrophysics Data System (ADS)
Jacobs, Tevis D. B.; Carpick, Robert W.
2013-02-01
Wear of sliding contacts leads to energy dissipation and device failure, resulting in massive economic and environmental costs. Typically, wear phenomena are described empirically, because physical and chemical interactions at sliding interfaces are not fully understood at any length scale. Fundamental insights from individual nanoscale contacts are crucial for understanding wear at larger length scales, and to enable reliable nanoscale devices, manufacturing and microscopy. Observable nanoscale wear mechanisms include fracture and plastic deformation, but recent experiments and models propose another mechanism: wear via atom-by-atom removal (`atomic attrition'), which can be modelled using stress-assisted chemical reaction kinetics. Experimental evidence for this has so far been inferential. Here, we quantitatively measure the wear of silicon--a material relevant to small-scale devices--using in situ transmission electron microscopy. We resolve worn volumes as small as 25 +/- 5 nm3, a factor of 103 lower than is achievable using alternative techniques. Wear of silicon against diamond is consistent with atomic attrition, and inconsistent with fracture or plastic deformation, as shown using direct imaging. The rate of atom removal depends exponentially on stress in the contact, as predicted by chemical rate kinetics. Measured activation parameters are consistent with an atom-by-atom process. These results, by direct observation, establish atomic attrition as the primary wear mechanism of silicon in vacuum at low loads.
New Perspectives on Tooth Wear
Lucas, Peter W.; Omar, Ridwaan
2012-01-01
Some of the efforts that have been made to document tooth wear are reviewed here with an emphasis on nonhuman mammals, literature with which dentists may not be very familiar. We project a change in research strategy from the description of wear at various scales of measurement towards investigation of the mechanical mechanisms that actually create the texture of a worn surface. These studies should reveal exactly how tooth tissue is lost and what aspects of the structure of dental tissues affect this. The most important aspects of the interaction between the tooth surface and wear particles would appear to be particle size, particle shape, their mechanical properties with respect to those of tooth tissues, and the influence of saliva. PMID:22536239
The interactions between attrition, abrasion and erosion in tooth wear.
Shellis, R Peter; Addy, Martin
2014-01-01
Tooth wear is the result of three processes: abrasion (wear produced by interaction between teeth and other materials), attrition (wear through tooth-tooth contact) and erosion (dissolution of hard tissue by acidic substances). A further process (abfraction) might potentiate wear by abrasion and/or erosion. Knowledge of these tooth wear processes and their interactions is reviewed. Both clinical and experimental observations show that individual wear mechanisms rarely act alone but interact with each other. The most important interaction is the potentiation of abrasion by erosive damage to the dental hard tissues. This interaction seems to be the major factor in occlusal and cervical wear. The available evidence is insufficient to establish whether abfraction is an important contributor to tooth wear in vivo. Saliva can modulate erosive/abrasive tooth wear, especially through formation of pellicle, but cannot prevent it. © 2014 S. Karger AG, Basel.
How to qualify and validate wear simulation devices and methods.
Heintze, S D
2006-08-01
The clinical significance of increased wear can mainly be attributed to impaired aesthetic appearance and/or functional restrictions. Little is known about the systemic effects of swallowed or inhaled worn particles that derive from restorations. As wear measurements in vivo are complicated and time-consuming, wear simulation devices and methods had been developed without, however, systematically looking at the factors that influence important wear parameters. Wear simulation devices shall simulate processes that occur in the oral cavity during mastication, namely force, force profile, contact time, sliding movement, clearance of worn material, etc. Different devices that use different force actuator principles are available. Those with the highest citation frequency in the literature are - in descending order - the Alabama, ACTA, OHSU, Zurich and MTS wear simulators. When following the FDA guidelines on good laboratory practice (GLP) only the expensive MTS wear simulator is a qualified machine to test wear in vitro; the force exerted by the hydraulic actuator is controlled and regulated during all movements of the stylus. All the other simulators lack control and regulation of force development during dynamic loading of the flat specimens. This may be an explanation for the high coefficient of variation of the results in some wear simulators (28-40%) and the poor reproducibility of wear results if dental databases are searched for wear results of specific dental materials (difference of 22-72% for the same material). As most of the machines are not qualifiable, wear methods applying the machine may have a sound concept but cannot be validated. Only with the MTS method have wear parameters and influencing factors been documented and verified. A good compromise with regard to costs, practicability and robustness is the Willytec chewing simulator, which uses weights as force actuator and step motors for vertical and lateral movements. The Ivoclar wear method run on
Tool Wear Monitoring Using Time Series Analysis
NASA Astrophysics Data System (ADS)
Song, Dong Yeul; Ohara, Yasuhiro; Tamaki, Haruo; Suga, Masanobu
A tool wear monitoring approach considering the nonlinear behavior of cutting mechanism caused by tool wear and/or localized chipping is proposed, and its effectiveness is verified through the cutting experiment and actual turning machining. Moreover, the variation in the surface roughness of the machined workpiece is also discussed using this approach. In this approach, the residual error between the actually measured vibration signal and the estimated signal obtained from the time series model corresponding to dynamic model of cutting is introduced as the feature of diagnosis. Consequently, it is found that the early tool wear state (i.e. flank wear under 40µm) can be monitored, and also the optimal tool exchange time and the tool wear state for actual turning machining can be judged by this change in the residual error. Moreover, the variation of surface roughness Pz in the range of 3 to 8µm can be estimated by the monitoring of the residual error.
Analysis of polyethylene wear in plain radiographs
2009-01-01
Background and purpose Two-dimensional computerized radiographic techniques are frequently used to measure in vivo polyethylene (PE) wear after total hip arthroplasty (THA), and several variables in the clinical set-up may influence the amount of wear that is measured. We compared the repeatability and concurrent validity of linear PE wear on plain radiographs using the same software but a different number of radiographs. Methods We used either 1, 2, or 6 anteroposterior (AP) hip radiographs of 11 patients from a clinical THA series with 12 years of follow-up, and measured the PE wear with the software PolyWare 3D Pro. Repeatability within and concurrent validity between the different numbers of radiograph strategies were assessed using limits of agreement (LOAs) and bias. Results Observed median wear (range) in mm was 3.4 (1.6–4.6), 2.3 (0.7–4.9), and 4.0 (2.6–6.2) for the 1-, 2-, and 6-radiograph strategies. For repeatability, no bias (p > 0.41) was observed. LOAs around the bias were ± 0.6, ± 0.4, and ± 1.2 mm for the 1-, 2-, and 6-radiograph strategies. For concurrent validity, a bias (± LOA) between all pairwise comparisons was observed (p < 0.02) with 0.8 mm (± 2.5) between the 1- and 2-radiograph strategies, 1.0 mm (± 2.2) between the 1- and 6-radiograph strategies, and 1.8 mm (± 1.2) between the 2- and 6-radiograph strategies. Interpretation The number of radiographs used for wear measurement with a shadow-casting analysis method on plain AP radiographs influences the amount of linear wear measured. Results of PE wear obtained with PolyWare in studies using a different number of radiographs are not comparable. PMID:19995318
Inspection of wear particles in oils by using a fuzzy classifier
NASA Astrophysics Data System (ADS)
Hamalainen, Jari J.; Enwald, Petri
1994-11-01
The reliability of stand-alone machines and larger production units can be improved by automated condition monitoring. Analysis of wear particles in lubricating or hydraulic oils helps diagnosing the wear states of machine parts. This paper presents a computer vision system for automated classification of wear particles. Digitized images from experiments with a bearing test bench, a hydraulic system with an industrial company, and oil samples from different industrial sources were used for algorithm development and testing. The wear particles were divided into four classes indicating different wear mechanisms: cutting wear, fatigue wear, adhesive wear, and abrasive wear. The results showed that the fuzzy K-nearest neighbor classifier utilized gave the same distribution of wear particles as the classification by a human expert.
NASA Astrophysics Data System (ADS)
Namdas, Ebinazar B.; Ruseckas, Arvydas; Samuel, Ifor D. W.; Lo, Shih-Chun; Burn, Paul L.
2005-02-01
We have studied triplet-triplet annihilation in neat films of electrophosphorescent fac-tris(2-phenylpyridine) iridium(III) [Ir(ppy)3]-cored dendrimers containing phenylene- and carbazole-based dendrons with 2-ethylhexyloxy surface groups using time-resolved photoluminescence. From measured annihilation rates, the limiting current densities above which annihilation would dominate in dendrimer light-emitting devices are found to be >1A/cm2. The triplet exciton diffusion length varies in the range of 2-10 nm depending on the dendron size. The distance dependence of the nearest-neighbor hopping rate shows that energy transfer is dominated by the exchange mechanism.
The Wear Behavior of Textured Steel Sliding against Polymers
Wang, Meiling; Zhang, Changtao; Wang, Xiaolei
2017-01-01
Artificially fabricated surface textures can significantly improve the friction and wear resistance of a tribological contact. Recently, this surface texturing technique has been applied to polymer materials to improve their tribological performance. However, the wear behavior of textured tribo-pairs made of steel and polymer materials has been less thoroughly investigated and is not well understood; thus, it needs further research. The aim of this study is to investigate the wear properties of tribological contacts made of textured stainless steel against polymer surfaces. Three polymer materials were selected in this study, namely, ultrahigh molecular weight polyethylene (UHMWPE), polyoxymethylene (POM) and (polyetheretherketone) PEEK. Wear tests were operated through a ring-on-plane mode. The results revealed that the texture features and material properties affected the wear rates and friction coefficients of the textured tribo-pairs. In general, PEEK/textured steel achieved the lowest wear rate among the three types of tribo-pairs investigated. Energy dispersive x-ray spectroscopy (EDX) analysis revealed that the elements of C and O on the contacting counterfaces varied with texture features and indicated different wear behavior. Experimental and simulated results showed differences in the stress distribution around the dimple edge, which may influence wear performance. Wear debris with different surface morphologies were found for tribo-pairs with varying texture features. This study has increased the understanding of the wear behavior of tribo-pairs between textured stainless steel and polymer materials. PMID:28772688
Paulus, Alexander Christoph; Franke, Manja; Kraxenberger, Michael; Schröder, Christian; Jansson, Volkmar
2015-01-01
Introduction. Overlooked polymethylmethacrylate after unicondylar knee arthroplasty can be a potential problem, since this might influence the generated wear particle size and morphology. The aim of this study was the analysis of polyethylene wear in a knee wear simulator for changes in size, morphology, and particle number after the addition of third-bodies. Material and Methods. Fixed bearing unicondylar knee prostheses (UKA) were tested in a knee simulator for 5.0 million cycles. Following bone particles were added for 1.5 million cycles, followed by 1.5 million cycles with PMMA particles. A particle analysis by scanning electron microscopy of the lubricant after the cycles was performed. Size and morphology of the generated wear were characterized. Further, the number of particles per 1 million cycles was calculated for each group. Results. The particles of all groups were similar in size and shape. The number of particles in the PMMA group showed 10-fold higher values than in the bone and control group (PMMA: 10.251 × 1012; bone: 1.145 × 1012; control: 1.804 × 1012). Conclusion. The addition of bone or PMMA particles in terms of a third-body wear results in no change of particle size and morphology. PMMA third-bodies generated tenfold elevated particle numbers. This could favor an early aseptic loosening. PMID:25866795
Drill wear monitoring in cortical bone drilling.
Staroveski, Tomislav; Brezak, Danko; Udiljak, Toma
2015-06-01
Medical drills are subject to intensive wear due to mechanical factors which occur during the bone drilling process, and potential thermal and chemical factors related to the sterilisation process. Intensive wear increases friction between the drill and the surrounding bone tissue, resulting in higher drilling temperatures and cutting forces. Therefore, the goal of this experimental research was to develop a drill wear classification model based on multi-sensor approach and artificial neural network algorithm. A required set of tool wear features were extracted from the following three types of signals: cutting forces, servomotor drive currents and acoustic emission. Their capacity to classify precisely one of three predefined drill wear levels has been established using a pattern recognition type of the Radial Basis Function Neural Network algorithm. Experiments were performed on a custom-made test bed system using fresh bovine bones and standard medical drills. Results have shown high classification success rate, together with the model robustness and insensitivity to variations of bone mechanical properties. Features extracted from acoustic emission and servomotor drive signals achieved the highest precision in drill wear level classification (92.8%), thus indicating their potential in the design of a new type of medical drilling machine with process monitoring capabilities. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.
Tool wear modeling using abductive networks
NASA Astrophysics Data System (ADS)
Masory, Oren
1992-09-01
A tool wear model based on Abductive Networks, which consists of a network of `polynomial' nodes, is described. The model relates the cutting parameters, components of the cutting force, and machining time to flank wear. Thus real time measurements of the cutting force can be used to monitor the machining process. The model is obtained by a training process in which the connectivity between the network's nodes and the polynomial coefficients of each node are determined by optimizing a performance criteria. Actual wear measurements of coated and uncoated carbide inserts were used for training and evaluating the established model.
Penter, Livius; Dietze, Kerstin; Bullinger, Lars; Westermann, Jörg; Rahn, Hans-Peter; Hansmann, Leo
2018-03-14
FACS index sorting allows the isolation of single cells with retrospective identification of each single cell's high-dimensional immune phenotype. We experimentally determine the error rate of index sorting and combine the technology with T cell receptor sequencing to identify clonal T cell expansion in aplastic anemia bone marrow as an example. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
46 CFR 169.825 - Wearing of safety belts.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false Wearing of safety belts. 169.825 Section 169.825 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS SAILING SCHOOL VESSELS Operations § 169.825 Wearing of safety belts. The master of each vessel shall ensure that each person wears...
46 CFR 169.825 - Wearing of safety belts.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 7 2011-10-01 2011-10-01 false Wearing of safety belts. 169.825 Section 169.825 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS SAILING SCHOOL VESSELS Operations § 169.825 Wearing of safety belts. The master of each vessel shall ensure that each person wears...
In vitro wear of various orthotic device materials.
Casey, Jeffery; Dunn, William J; Wright, Edward
2003-11-01
Orthotic devices are advocated to decrease occlusal attrition caused by bruxism but tend to wear with time. This study investigated the wear rate of various materials used to fabricate orthotic devices. Five experimental groups (n=8) were studied: Splint Biocryl autopolymerized (SBA), Splint Biocryl autopolymerized plus additional heat and pressure (SBHP), Forestacryl autopolymerized (FA), Forestacryl autopolymerized plus additional heat and pressure (FHP), and Quick Splint 15-minute (QS), light-polymerized composite. Specimens were mounted to the base of a universal testing machine. A wear device using steatite balls and a load of 9.1 kg was positioned against the specimens, submerged in a 37 degrees C water bath and subjected to 2500 reciprocal cycles. Wear, in micrometers, was calculated as the maximum peak to valley measurement (Ry) using profilometry. Data were subjected to analysis of variance (ANOVA) and Tukey's HSD (alpha=.05). Mean acrylic wear in micrometers was as follows: FA 6.8 +/-3.0; FHP 7.1 +/- 1.8; SBA 20.4 +/- 5.6; SBHP 23.7 +/- 7.8; and QS 23.8 +/- 6.9. One-way ANOVA detected significant differences between groups (P<.001); the Tukey honestly significant difference test determined that FA and FHP specimens were significantly more resistant to wear than all other specimens (P=.007). Differences in in vitro wear resistance among various orthotic device materials exist. The in vitro wear resistance among other autopolymerizing materials appears to be related to proprietary differences.
Geotribology - Friction, wear, and lubrication of faults
NASA Astrophysics Data System (ADS)
Boneh, Yuval; Reches, Ze'ev
2018-05-01
We introduce here the concept of Geotribology as an approach to study friction, wear, and lubrication of geological systems. Methods of geotribology are applied here to characterize the friction and wear associated with slip along experimental faults composed of brittle rocks. The wear in these faults is dominated by brittle fracturing, plucking, scratching and fragmentation at asperities of all scales, including 'effective asperities' that develop and evolve during the slip. We derived a theoretical model for the rate of wear based on the observation that the dynamic strength of brittle materials is proportional to the product of load stress and loading period. In a slipping fault, the loading period of an asperity is inversely proportional to the slip velocity, and our derivations indicate that the wear-rate is proportional to the ratio of [shear-stress/slip-velocity]. By incorporating the rock hardness data into the model, we demonstrate that a single, universal function fits wear data of hundreds of experiments with granitic, carbonate and sandstone faults. In the next step, we demonstrate that the dynamic frictional strength of experimental faults is well explained in terms of the tribological parameter PV factor (= normal-stress · slip-velocity). This factor successfully delineates weakening and strengthening regimes of carbonate and granitic faults. Finally, our analysis revealed a puzzling observation that wear-rate and frictional strength have strikingly different dependencies on the loading conditions of normal-stress and slip-velocity; we discuss sources for this difference. We found that utilization of tribological tools in fault slip analyses leads to effective and insightful results.
DOT National Transportation Integrated Search
1985-09-01
This report examines the groove wear variability among tires subjected to the : Uniform Tire Quality Grading (UTQC) test procedure for determining tire tread wear. : The effects of heteroscedasticity (variable variance) on a previously reported : sta...
Load application for the contact mechanics analysis and wear prediction of total knee replacement.
Zhang, Jing; Chen, Zhenxian; Wang, Ling; Li, Dichen; Jin, Zhongmin
2017-05-01
Tibiofemoral contact forces in total knee replacement have been measured at the medial and lateral sites respectively using an instrumented prosthesis, and predicted from musculoskeletal multibody dynamics models with a reasonable accuracy. However, it is uncommon that the medial and lateral forces are applied separately to replace a total axial load according to the ISO standard in the majority of current finite element analyses. In this study, we quantified the different effects of applying the medial and lateral loads separately versus the traditional total axial load application on contact mechanics and wear prediction of a patient-specific knee prosthesis. The load application position played an important role under the medial-lateral load application. The loading set which produced the closest load distribution to the multibody dynamics model was used to predict the contact mechanics and wear for the prosthesis and compared with the total axial load application. The medial-lateral load distribution using the present method was found to be closer to the multibody dynamics prediction than the traditional total axial load application, and the maximum contact pressure and contact area were consistent with the corresponding load variation. The predicted total volumetric wear rate and area were similar between the two load applications. However, the split of the predicted wear volumes on the medial and the lateral sides was different. The lateral volumetric wear rate was 31.46% smaller than the medial from the traditional load application prediction, while from the medial-lateral load application, the lateral side was only 11.8% smaller than the medial. The medial-lateral load application could provide a new and more accurate method of load application for patient-specific preclinical contact mechanics and wear prediction of knee implants.
Potential countersample materials for in vitro simulation wear testing.
Shortall, Adrian C; Hu, Xiao Q; Marquis, Peter M
2002-05-01
Any laboratory investigation of the wear resistance of dental materials needs to consider oral conditions so that in vitro wear results can be correlated with in vivo findings. The choice of the countersample is a critical factor in establishing the pattern of tribological wear and in achieving an efficient in vitro wear testing system. This research investigated the wear behavior and surface characteristics associated with three candidate countersample materials used for in vitro wear testing in order to identify a possible suitable substitute for human dental enamel. Three candidate materials, stainless steel, steatite and dental porcelain were evaluated and compared to human enamel. A variety of factors including hardness, wear surface evolution and frictional coefficients were considered, relative to the tribology of the in vivo situation. The results suggested that the dental porcelain investigated bore the closest similarity to human enamel of the materials investigated. Assessment of potential countersample materials should be based on the essential tribological simulation supported by investigations of mechanical, chemical and structural properties. The selected dental porcelain had the best simulating ability among the three selected countersample materials and this class of material may be considered as a possible countersample material for in vitro wear test purposes. Further studies are required, employing a wider range of dental ceramics, in order to optimise the choice of countersample material for standardized in vitro wear testing.
A model for predicting wear rates in tooth enamel.
Borrero-Lopez, Oscar; Pajares, Antonia; Constantino, Paul J; Lawn, Brian R
2014-09-01
It is hypothesized that wear of enamel is sensitive to the presence of sharp particulates in oral fluids and masticated foods. To this end, a generic model for predicting wear rates in brittle materials is developed, with specific application to tooth enamel. Wear is assumed to result from an accumulation of elastic-plastic micro-asperity events. Integration over all such events leads to a wear rate relation analogous to Archard׳s law, but with allowance for variation in asperity angle and compliance. The coefficient K in this relation quantifies the wear severity, with an arbitrary distinction between 'mild' wear (low K) and 'severe' wear (high K). Data from the literature and in-house wear-test experiments on enamel specimens in lubricant media (water, oil) with and without sharp third-body particulates (silica, diamond) are used to validate the model. Measured wear rates can vary over several orders of magnitude, depending on contact asperity conditions, accounting for the occurrence of severe enamel removal in some human patients (bruxing). Expressions for the depth removal rate and number of cycles to wear down occlusal enamel in the low-crowned tooth forms of some mammals are derived, with tooth size and enamel thickness as key variables. The role of 'hard' versus 'soft' food diets in determining evolutionary paths in different hominin species is briefly considered. A feature of the model is that it does not require recourse to specific material removal mechanisms, although processes involving microplastic extrusion and microcrack coalescence are indicated. Published by Elsevier Ltd.
Safe sorting of GFP-transduced live cells for subsequent culture using a modified FACS vantage.
Sørensen, T U; Gram, G J; Nielsen, S D; Hansen, J E
1999-12-01
A stream-in-air cell sorter enables rapid sorting to a high purity, but it is not well suited for sorting of infectious material due to the risk of airborne spread to the surroundings. A FACS Vantage cell sorter was modified for safe use with potentially HIV infected cells. Safety tests with bacteriophages were performed to evaluate the potential spread of biologically active material during cell sorting. Cells transduced with a retroviral vector carrying the gene for GFP were sorted on the basis of their GFP fluorescence, and GFP expression was followed during subsequent culture. The bacteriophage sorting showed that the biologically active material was confined to the sorting chamber. A failure mode simulating a nozzle blockage resulted in detectable droplets inside the sorting chamber, but no droplets could be detected when an additional air suction from the sorting chamber had been put on. The GFP transduced cells were sorted to 99% purity. Cells not expressing GFP at the time of sorting did not turn on the gene during subsequent culture. Un-sorted cells and cells sorted to be positive for GFP showed a decrease in the fraction of GFP positive cells during culture. Sorting of live infected cells can be performed safely and with no deleterious effects on vector expression using the modified FACS Vantage instrument. Copyright 1999 Wiley-Liss, Inc.
Dynamic-scanning-electron-microscope study of friction and wear
NASA Technical Reports Server (NTRS)
Brainard, W. A.; Buckley, D. H.
1974-01-01
A friction and wear apparatus was built into a real time scanning electron microscope (SEM). The apparatus and SEM comprise a system which provides the capability of performing dynamic friction and wear experiments in situ. When the system is used in conjunction with dispersive X-ray analysis, a wide range of information on the wearing process can be obtained. The type of wear and variation with speed, load, and time can be investigated. The source, size, and distribution of wear particles can be determined and metallic transferal observed. Some typical results obtained with aluminum, copper, and iron specimens are given.
Asperity-Level Origins of Transition from Mild to Severe Wear
NASA Astrophysics Data System (ADS)
Aghababaei, Ramin; Brink, Tobias; Molinari, Jean-François
2018-05-01
Wear is the inevitable damage process of surfaces during sliding contact. According to the well-known Archard's wear law, the wear volume scales with the real contact area and as a result is proportional to the load. Decades of wear experiments, however, show that this relation only holds up to a certain load limit, above which the linearity is broken and a transition from mild to severe wear occurs. We investigate the microscopic origins of this breakdown and the corresponding wear transition at the asperity level. Our atomistic simulations reveal that the interaction between subsurface stress fields of neighboring contact spots promotes the transition from mild to severe wear. The results show that this interaction triggers the deep propagation of subsurface cracks and the eventual formation of large debris particles, with a size corresponding to the apparent contact area of neighboring contact spots. This observation explains the breakdown of the linear relation between the wear volume and the normal load in the severe wear regime. This new understanding highlights the critical importance of studying contact beyond the elastic limit and single-asperity models.
Detecting Wear In Ball Bearings During Operation
NASA Technical Reports Server (NTRS)
Hine, Michael J.
1988-01-01
Strain-gauge signals at harmonics of ball-bearing-cage frequencies signify wear. Brief report describes experiments in continuing effort to interpret vibrations of machinery in terms of wear in ball bearing.
Dental Wear: A Scanning Electron Microscope Study
Levrini, Luca; Di Benedetto, Giulia
2014-01-01
Dental wear can be differentiated into different types on the basis of morphological and etiological factors. The present research was carried out on twelve extracted human teeth with dental wear (three teeth showing each type of wear: erosion, attrition, abrasion, and abfraction) studied by scanning electron microscopy (SEM). The study aimed, through analysis of the macro- and micromorphological features of the lesions (considering the enamel, dentin, enamel prisms, dentinal tubules, and pulp), to clarify the different clinical and diagnostic presentations of dental wear and their possible significance. Our results, which confirm current knowledge, provide a complete overview of the distinctive morphology of each lesion type. It is important to identify the type of dental wear lesion in order to recognize the contributing etiological factors and, consequently, identify other more complex, nondental disorders (such as gastroesophageal reflux, eating disorders). It is clear that each type of lesion has a specific morphology and mechanism, and further clinical studies are needed to clarify the etiological processes, particularly those underlying the onset of abfraction. PMID:25548769
Investigation on wear characteristic of biopolymer gear
NASA Astrophysics Data System (ADS)
Ghazali, Wafiuddin Bin Md; Daing Idris, Daing Mohamad Nafiz Bin; Sofian, Azizul Helmi Bin; Basrawi, Mohamad Firdaus bin; Khalil Ibrahim, Thamir
2017-10-01
Polymer is widely used in many mechanical components such as gear. With the world going to a more green and sustainable environment, polymers which are bio based are being recognized as a replacement for conventional polymers based on fossil fuel. The use of biopolymer in mechanical components especially gear have not been fully explored yet. This research focuses on biopolymer for spur gear and whether the conventional method to investigate wear characteristic is applicable. The spur gears are produced by injection moulding and tested on several speeds using a custom test equipment. The wear formation such as tooth fracture, tooth deformation, debris and weight loss was observed on the biopolymer spur gear. It was noted that the biopolymer gear wear mechanism was similar with other type of polymer spur gears. It also undergoes stages of wear which are; running in, linear and rapid. It can be said that the wear mechanism of biopolymer spur gear is comparable to fossil fuel based polymer spur gear, thus it can be considered to replace polymer gears in suitable applications.
The friction and wear of carbon-carbon composites for aircraft brakes
NASA Astrophysics Data System (ADS)
Hutton, Toby
Many carbon-carbon composite aircraft brakes encounter high wear rates during low energy braking operations. The work presented in this thesis addresses this issue, but it also elucidates the microstructural changes and wear mechanisms that take place in these materials during all braking conditions encountered by aircraft brakes. A variety of investigations were conducted using friction and wear testing, as well as examination of wear surfaces and wear debris using OM, SEM, X-RD, TGA and Density Gradient Separation (DOS). Friction and wear tests were conducted on a PAN fibre/CVI matrix carbon-carbon composite (Dunlop) and a pitch fibre/Resin-CVI matrix carbon-carbon composite (Bendix). Extensive testing was undertaken on the Dunlop composites to asses the effects of composite architecture, fibre orientation and heat treatment temperatures on friction and wear. Other friction and wear tests, conducted on the base Dunlop composite, were used to investigate the relative influences of temperature and sliding speed. It was found that the effect of temperature was dominant over composite architecture, fibre orientation and sliding speed in governing the friction and wear performance of the Dunlop composites. The development of bulk temperatures in excess of 110 C by frictional heating resulted in smooth friction and a low wear rate. Reducing heat treatment temperature also reduced the thermal conductivity producing high interface temperatures, low smooth friction coefficients and low wear rates under low energy braking conditions. However, this was at the expense of high oxidative wear rates under higher energy braking conditions. The Bendix composites had lower thermal conductivities than the fully heat treated Dunlop composite and exhibited similar friction and wear behaviour to Dunlop composites heat treated to lower temperatures. Examination of the wear surfaces using OM and SEM revealed particulate or Type I surface debris on wear surfaces tested under low energy
Wear Characteristics and Mechanisms of H13 Steel with Various Tempered Structures
NASA Astrophysics Data System (ADS)
Cui, X. H.; Wang, S. Q.; Wei, M. X.; Yang, Z. R.
2011-08-01
Wear tests of H13 steel with various tempering microstructures were performed under atmospheric conditions at room temperature (RT), 200 °C, and 400 °C. The wear characteristics and wear mechanisms of various tempered microstructures of the steel were focused by investigating the structure, morphology, and composition of the worn surfaces. Under atmospheric conditions at RT, 200 °C, and 400 °C, adhesive wear, mild oxidation wear, and oxidation wear prevailed, respectively. The wear rate at 200 °C was substantially lower than those at RT and 400 °C due to the protection of tribo-oxides. In mild oxidation wear, the tempered microstructures of the steel presented almost no obvious influence on the wear resistance. However, in adhesive wear and oxidation wear, the wear resistance strongly depended on the tempered microstructures of the steel. The steel tempered at 600-650 °C presented pronouncedly lower wear rates than the one tempered at 200-550 or 700 °C. It can be suggested that the wear resistance of the steel was closely related with its fracture resistance.
Tooth wear in children with Down syndrome.
Bell, E J; Kaidonis, J; Townsend, G C
2002-03-01
Several studies have described the impact that dental caries and periodontitis may have on the dentitions of individuals with Down syndrome, but there are few reports about the effects of tooth wear. This investigation aimed to compare the aetiology, prevalence and severity of tooth wear in 49 cytogenetically confirmed Down syndrome children with 49 non-Down syndrome controls. This study involved three aspects: an oral examination, including obtaining dental impressions; a dietary analysis spanning three days; and a questionnaire seeking information about habits, medical problems and medications. Tooth wear severity was scored on a 4-grade scale (none-to-little; moderate; severe; very severe), while aetiology was classified as being due to attrition mainly, erosion mainly, or a combination of both. Double determinations established scoring method reliability and chi-square tests assessed associations between samples. Tooth wear was significantly more frequent (p<0.01) in the Down syndrome than the non-Down syndrome sample (67.4 per cent cf 34.7 per cent), with more of the Down syndrome children showing severe to very severe wear (59.2 per cent cf 8.2 per cent). Significantly more Down syndrome children (p<0.05) displayed a multifactorial aetiology of tooth wear, i.e., both attrition and erosion (46.7 per cent cf 28.6 per cent), although no particular dietary link was established. Gastric reflux and vomiting were reported in over 20 per cent of the Down syndrome sample. Given the potential consequences of high levels of tooth wear, associated with tooth grinding and an acidic oral environment in Down syndrome children, educational programmes aimed at increasing awareness of carers and health professionals are needed urgently.
Wear Properties of ECAP-Processed AM80 Magnesium Alloy
NASA Astrophysics Data System (ADS)
Gopi, K. R.; Shivananda Nayaka, H.; Sahu, Sandeep
2017-07-01
AM80 magnesium alloy was subjected to equal-channel angular pressing (ECAP), and microstructural evolution was studied using scanning electron microscope (SEM). Grain size was found to decrease up to 3 µm after four passes. An increase in number of ECAP passes led to a corresponding increase in hardness of the processed samples. Unprocessed and ECAP-processed samples were subjected to wear test using pin-on-disk wear test machine to study the wear behavior. Effects of varying loads (30 and 40 N) with sliding distances (2500 and 5000 m) were studied. The results showed reduction in wear mass loss for the ECAP-processed samples in comparison with unprocessed condition. Coefficient of friction (COF) was studied for different loads, and improvement in COF values was observed for ECAP-processed samples compared to unprocessed condition. Worn surfaces were studied using SEM and energy-dispersive x-ray spectrometer, and they exhibited plastic deformation, delamination, plowing, wear debris and oxidation in the sliding direction. X-ray diffraction analysis was conducted on the worn surfaces to identify the phases. It revealed the presence of magnesium oxide and magnesium aluminum oxide which led to oxidation wear in the sliding direction. Wear mechanism was found to be abrasive and oxidation wear.
Steady-state wear and friction in boundary lubrication studies
NASA Technical Reports Server (NTRS)
Loomis, W. R.; Jones, W. R., Jr.
1980-01-01
A friction and wear study was made at 20 C to obtain improved reproducibility and reliability in boundary lubrication testing. Ester-base and C-ether-base fluids were used to lubricate a pure iron rider in sliding contact with a rotating M-50 steel disk in a friction and wear apparatus. Conditions included loads of 1/2 and 1 kg and sliding velocities of 3.6 to 18.2 m/min in a dry air atmosphere and stepwise time intervals from 1 to 250 min for wear measurements. The wear rate results were compared with those from previous studies where a single 25 min test period was used. Satisfactory test conditions for studying friction and wear in boundary lubrication for this apparatus were found to be 1 kg load; sliding velocities of 7.1 to 9.1 m/min (50 rpm disk speed); and use of a time stepwise test procedure. Highly reproducible steady-state wear rates and steady-state friction coefficients were determined under boundary conditions. Wear rates and coefficients of friction were constant following initially high values during run-in periods.
Study of Two-Body Wear Performance of Dental Materials.
Hu, Xin; Zhang, Qian; Ning, Jia; Wu, Wenmeng; Li, Changyi
2018-06-01
The purpose of this study was to evaluate the two-body wear resistances of natural enamel and four dental materials in vitro. The testing machine was modified to form a type of pin-on-disk wear test apparatus. Four dental material specimens (Au-Pd alloy, Ag-Pd alloy, FiltekTMP60 and FiltekTMZ350 composite resins) and enamel were used as the pins, and a steatite ceramic grinding wheel was used as the abrasive counter face. The wear volume loss and the rigidity value was measured. The worn surface and the element analysis of the debris were analyzed. The wear volume loss of Au-Pd alloy and its steatite antagonists were the nearest to those of the dental enamel. SEM microphotographs showed that, the main wear mechanism of the dental materials was abrasive and adhesive wear. Au-Pd alloy had good wear resistance and was more suitable for dental applications than other three dental materials. Copyright © 2017 National Medical Association. Published by Elsevier Inc. All rights reserved.
Tool Wear Feature Extraction Based on Hilbert Marginal Spectrum
NASA Astrophysics Data System (ADS)
Guan, Shan; Song, Weijie; Pang, Hongyang
2017-09-01
In the metal cutting process, the signal contains a wealth of tool wear state information. A tool wear signal’s analysis and feature extraction method based on Hilbert marginal spectrum is proposed. Firstly, the tool wear signal was decomposed by empirical mode decomposition algorithm and the intrinsic mode functions including the main information were screened out by the correlation coefficient and the variance contribution rate. Secondly, Hilbert transform was performed on the main intrinsic mode functions. Hilbert time-frequency spectrum and Hilbert marginal spectrum were obtained by Hilbert transform. Finally, Amplitude domain indexes were extracted on the basis of the Hilbert marginal spectrum and they structured recognition feature vector of tool wear state. The research results show that the extracted features can effectively characterize the different wear state of the tool, which provides a basis for monitoring tool wear condition.
Structures and Properties of Polymers Important to Their Wear Behavior
NASA Technical Reports Server (NTRS)
Tanaka, K.
1984-01-01
The wear and transfer of various semicrystalline polymers sliding against smooth steel or glass surfaces were examined. The effects of structures, and properties of polymers on their wear behavior are discussed. It is found that the high wear characteristics of PTFE is due to the easy destruction of the banded structure of PTFE. The size of spherulites and the molecular profile are closely related to the magnitude of wear rates of typical semicrystalline polymers. The effects of these factors on the wear rate on the basis of the destruction or melting of spherulites at the frictional surface are discussed. Although the fatigue theory of wear indicates that some mechanical properties are important to wear behavior, it is shown that the theory does not always explain the experimental result obtained on a smooth surface.
Tables for estimating skidder tire wear
Cleveland J. Biller; Cleveland J. Biller
1970-01-01
This book of tables was prepared to help the logging operator estimate how much a particular logging job will wear the tires on his rubber-wheeled skidders. This is an important element in the cost of a logging operation. The logging operator can translate these estimates of tire wear into a production cost.
Detailed study of oxidation/wear mechanism in lox turbopump bearings
NASA Technical Reports Server (NTRS)
Chase, T. J.; Mccarty, J. P.
1993-01-01
Wear of 440C angular contact ball bearings of the phase 2 high pressure oxygen turbopump (HPOTP) of the space shuttle main engine (SSME) has been studied by means of various advanced nondestructive techniques (NDT) and modeled with reference to all known material, design, and operation variables. Three modes dominating the wear scenario were found to be the adhesive/sheer peeling (ASP), oxidation, and abrasion. Bearing wear was modeled in terms of the three modes. Lacking a comprehensive theory of rolling contact wear to date, each mode is modeled after well-established theories of sliding wear, while sliding velocity and distance are related to microsliding in ball-to-ring contacts. Microsliding, stress, temperature, and other contact variables are evaluated with analytical software packages of SHABERTH(TM)/SINDA(TM) and ADORE(TM). Empirical constants for the models are derived from NIST experiments by applying the models to the NIST wear data. The bearing wear model so established precisely predicts quite well the average ball wear rate for the HPOTP bearings. The wear rate has been statistically determined for the entire population of flight and development bearings based on Rocketdyne records to date. Numerous illustrations are given.
NASA Astrophysics Data System (ADS)
Yin, Cun-hong; Liang, Yi-long; Jiang, Yun; Yang, Ming; Long, Shao-lei
2017-11-01
The microstructures of 20CrNi2Mo steel underneath the contact surface were examined after dry sliding. Scanning Electronic Microscopy (SEM), Transmission Electron Microscopy (TEM), Electron Backscattered Diffraction (EBSD) and an ultra-micro-hardness tester were used to characterize the worn surface and dry sliding wear-induced layer. Martensite laths were ultra-refined due to cumulative strains and a large strain gradient that occurred during cyclic loading in wear near the surface. The microstructure evolution in dominant abrasive wear differs from that in adhesive wear. In dominant abrasive wear, only bent martensite laths with high-density deformation dislocations were observed. In contrast, in dominant adhesive wear, gradient structures were formed along the depth from the wear surface. Cross-sectional TEM foils were prepared in a focused ion beam (FIB) to observe the gradient structures in a dry sliding wear-induced layer at depths of approximately 1-5 μm and 5-20 μm. The gradient structures contained nano-laminated structures with an average thickness of 30-50 nm and bent martensite laths. We found that the original martensite laths coordinated with the strain energy and provided origin boundaries for the formation of gradient structures. Geometrically necessary boundaries (GNBs) and isolated dislocation boundaries (IDBs) play important roles in forming the nano-laminated structures.
Lal, S; Hall, R M; Tipper, J L
2016-09-15
Ceramics have been used to deliver significant improvements in the wear properties of orthopaedic bearing materials, which has made it challenging to isolate wear debris from simulator lubricants. Ceramics such as silicon nitride, as well as ceramic-like surface coatings on metal substrates have been explored as potential alternatives to conventional implant materials. Current isolation methods were designed for isolating conventional metal, UHMWPE and ceramic wear debris. In this paper, we describe a methodology for isolation and recovery of ceramic or ceramic-like coating particles and metal wear particles from serum lubricants under ultra-low and low wear performance. Enzymatic digestion was used to digest the serum proteins and sodium polytungstate was used as a novel density gradient medium to isolate particles from proteins and other contaminants by ultracentrifugation. This method demonstrated over 80% recovery of particles and did not alter the size or morphology of ceramic and metal particles during the isolation process. Improvements in resistance to wear and mechanical damage of the articulating surfaces have a large influence on longevity and reliability of joint replacement devices. Modern ceramics have demonstrated ultra-low wear rates for hard-on-hard total hip replacements. Generation of very low concentrations of wear debris in simulator lubricants has made it challenging to isolate the particles for characterisation and further analysis. We have introduced a novel method to isolate ceramic and metal particles from serum-based lubricants using enzymatic digestion and novel sodium polytungstate gradients. This is the first study to demonstrate the recovery of ceramic and metal particles from serum lubricants at lowest detectable in vitro wear rates reported in literature. Copyright © 2016. Published by Elsevier Ltd.
The wear of cross-linked polyethylene against itself.
Joyce, T J; Ash, H E; Unsworth, A
1996-01-01
Cross-linked polyethylene (XLPE) may have an application as a material for an all-plastic surface replacement finger joint. It is inexpensive, biocompatible and can be injection-moulded into the complex shapes that are found on the ends of the finger bones. Further, the cross-linking of polyethylene has significantly improved its mechanical properties. Therefore, the opportunity exists for an all-XLPE joint, and so the wear characteristics of XLPE sliding against itself have been investigated. Wear tests were carried out on both reciprocating pin-on-plate machines and a finger function simulator. The reciprocating pin-on-plate machines had pins loaded at 10 N and 40 N. All pin-on-plate tests show wear factors from the plates very much greater than those of the pins. After 349 km of sliding, a mean wear factor of 0.46 x 10(-6) mm3/N m was found for the plates compared with 0.021 x 10(-6) mm3/N m for the pins. A fatigue mechanism may be causing this phenomenon of greater plate wear. Tests using the finger function simulator give an average wear rate of 0.22 x 10(-6) mm3/N m after 368 km. This sliding distance is equivalent to 12.5 years of use in vivo. The wear factors found were comparable with those of ultra-high molecular weight polyethylene (UHMWPE) against a metallic counterface and, therefore, as the loads across the finger joint are much less than those across the knee or the hip, it is probable that an all-XLPE finger joint will be viable from a wear point of view.
Sando, Steven K.; Vecchia, Aldo V.; Lorenz, David L.; Barnhart, Elliott P.
2014-01-01
A large-scale trend analysis was done on specific conductance, selected trace elements (arsenic, cadmium, copper, iron, lead, manganese, and zinc), and suspended-sediment data for 22 sites in the upper Clark Fork Basin for water years 1996–2010. Trend analysis was conducted by using two parametric methods: a time-series model (TSM) and multiple linear regression on time, streamflow, and season (MLR). Trend results for 1996–2010 indicate moderate to large decreases in flow-adjusted concentrations (FACs) and loads of copper (and other metallic elements) and suspended sediment in Silver Bow Creek upstream from Warm Springs. Deposition of metallic elements and suspended sediment within Warm Springs Ponds substantially reduces the downstream transport of those constituents. However, mobilization of copper and suspended sediment from floodplain tailings and stream banks in the Clark Fork reach from Galen to Deer Lodge is a large source of metallic elements and suspended sediment, which also affects downstream transport of those constituents. Copper and suspended-sediment loads mobilized from within this reach accounted for about 40 and 20 percent, respectively, of the loads for Clark Fork at Turah Bridge (site 20); whereas, streamflow contributed from within this reach only accounted for about 8 percent of the streamflow at Turah Bridge. Minor changes in FACs and loads of copper and suspended sediment are indicated for this reach during 1996–2010. Clark Fork reaches downstream from Deer Lodge are relatively smaller sources of metallic elements than the reach from Galen to Deer Lodge. In general, small decreases in loads and FACs of copper and suspended sediment are indicated for Clark Fork sites downstream from Deer Lodge during 1996–2010. Thus, although large decreases in FACs and loads of copper and suspended sediment are indicated for Silver Bow Creek upstream from Warm Springs, those large decreases are not translated to the more downstream reaches largely
Friction and wear of iron in sulfuric acid
NASA Technical Reports Server (NTRS)
Rengstorff, G. W. P.; Miyoshi, K.; Buckley, D. H.
1983-01-01
Elemental iron sliding on aluminum oxide in aerated sulfuric acid concentrations ranging from very dilute (0.000007 N; i.e., 4 ppm) to very concentrated (96 percent acid) was studied. Load and reciprocating sliding speeds were kept constant. With the most dilute acid of 0.7 to 0.0002 N, a complex corrosion product formed that was friable and often increased friction and wear. At concentrations of 0.001 N, metal losses were essentially by wear alone. Because no buildup of corrosion products occurred, this acid concentration became the standard from which to separate metal loss from direct corrosion and mechanical wear losses. When the acid concentration was increased to 5 percent, the high corrosion rate of iron in sulfuric acid strongly dominated the total wear loss. This strong corrosion increased to 30 percent acid, and decreased somewhat at 50 percent in accordance with expectations. However, the low corrosion of iron expected at acid concentrations of 65 to 96 percent was not observed in the wear area. It is apparent that the normal passivating film was being worn away and a galvanic cell established which rapidly attached to the wear area.
NASA interdisciplinary collaboration in tribology. A review of oxidational wear
NASA Technical Reports Server (NTRS)
Quinn, T. F. J.
1983-01-01
An in-depth review of oxidational wear of metals is presented. Special emphasis is given to a description of the concept of oxidational wear and the formulation of an Oxidational Wear Theory. The parallelism between the formation of an oxide film for dry contact conditions and the formation of other surface films for a lubricated contact is discussed. The description of oxidational wear is prefaced with a unification of wear modes into two major classes of mild and severe wear including both lubricated and dry contacts. Oxidational wear of metals is a class of mild wear where protective oxide films are formed at real areas of contact and during the time of contact at temperataure T sub c. When the oxide reaches a critical thickness, frequently in the range of 1 to 3 microns, the oxide breaks up and eventually appears as a wear particle. These oxides are preferentially formed on plateaux which alternately carry the load as they reach their critical thickness and are removed. If the system is operated at elevated temperatures, thick oxides can form both out of contact and between the plateaux. Temperature is important in determining the structure of the oxide film present. Spinel oxide (Fe3O4) which forms above 300 C is more protective than the lower temperature rhomobohedral (alpha-Fe2O3) oxide which is abrasive. An Oxidational Wear Theory is derived using a modified Archard wear law expressed in terms of activation energy (Qp) and Arrhenius constant (Ap).
Prevalence and Indicators of Tooth Wear among Chinese Adults
Wei, Zhao; Du, Yangge; Zhang, Jing; Tai, Baojun
2016-01-01
Numerous epidemiological studies have focused on the prevalence and related indicators of tooth wear. However, no sufficient studies have been conducted with Chinese adults. The purpose of this study was to assess the prevalence of tooth wear and identify related indicators among adults aged 36 to 74 years in Wuhan City, P.R. China. A cross-sectional and analytic study was conducted with 720 participants, aged 35–49 yrs and 50–74 yrs, in 2014. Each age group included 360 participants, of which 50% were males and 50% were females. All participants completed a questionnaire before examination. Tooth wear was assessed using the modified Basic Erosive Wear Examination (BEWE) index. The data were analyzed using the chi-square test and binary logistic regression analysis. The prevalence of tooth wear was 67.5% and 100% in the 35–49 and 50–74 age groups, respectively. The prevalence of dentin exposure was 64.7% and 98.3%, respectively. A significantly higher prevalence of tooth wear and dentin exposure was found in the 50–74 yr group than in the 35–49 yr group (p < 0.05). Critical indicators of tooth wear and dentin exposure included high frequency of acidic drinks and foods consumption, low socio-economic status, and unilateral chewing. The frequency of changing toothbrushes and the habit of drinking water during meals were associated with tooth wear. In addition, the usage of hard-bristle toothbrushes and consuming vitamin C and aspirin were found to be linked with dentin exposure. In conclusion, the prevalence of tooth wear and dentin exposure observed in Chinese adults was high, and the results revealed an association between tooth wear and socio-behavioral risk indicators. PMID:27583435
Longitudinal study of gastroesophageal reflux and erosive tooth wear.
Wilder-Smith, Clive H; Materna, Andrea; Martig, Lukas; Lussi, Adrian
2017-10-25
Approximately 60% of patients presenting to dentists with erosive tooth wear have significant gastroesophageal reflux (GERD), despite minor reflux symptoms. No longitudinal studies of reflux-associated erosive tooth wear and of reflux characteristics have been reported to date. The aim of this study was to characterize the longitudinal course of GERD and of associated erosive tooth wear, as well as factors predictive of its progression, in a large group of patients. Seventy-two patients presenting to dentists with clinically significant erosive tooth wear and increased esophageal acid exposure by 24-h multichannel intraluminal pH-impedance measurement (MII-pH) were re-assessed clinically and by MII-pH after 1 year treatment with esomeprazole 20 mg twice-daily. Predictive factors for erosive tooth wear were assessed by logistic regression. At follow-up, no further progression in erosive tooth wear was observed in 53 (74%) of patients. The percentage of time with a pH < 4, the number of acid reflux episodes and the percentage of proximal esophageal reflux off-PPI did not change significantly after one year, but the number of weakly acidic reflux episodes decreased significantly in the large subgroup without progression. None of the baseline demographic, clinical, endoscopic or esophageal acid exposure characteristics were significantly associated with progression of erosive tooth wear at follow-up. In this longitudinal study in patients with erosive tooth wear and oligosymptomatic GERD receiving esomeprazole for one year, erosive tooth wear did not progress further in the majority of patients. Background acidic esophageal reflux exposure appeared stable over time, whereas weakly acidic exposure decreased significantly in patients without erosion progression. MII-pH measurements on-PPI and with healthy controls will be useful in the further elucidation of the causal role of reflux in erosive tooth wear. ClinicalTrials.gov , retrospectively registered: NCT02087345 .
DOT National Transportation Integrated Search
1968-06-01
This report primarily investigates the wear characteristics of concrete using various cement contents and three different sources of aggregates. Compressive strength and dynamic modulus of elasticity data was also obtained to assist in the evaluation...
Twala, T N; Schutte-Smith, M; Roodt, A; Visser, H G
2015-02-21
A range of fac-[Mn(CO)3(L,L'-Bid)(H2O)](n) (L,L'-Bid = neutral or monoanionic bidentate ligands with varied L,L' donor atoms, N,N' and N,O, 1,10-phenanthroline, 2,2'-bipyridine, 2-picolinate, 2,4-quinolinate; n = 0, +1) has been synthesized and the methanol substitution has been investigated for the first time. The complexes were characterized by UV/vis, IR and NMR spectroscopy and X-ray crystallographic studies of the compounds fac-[Mn(CO)3(Bipy)(H2O)][CF3SO3] () and fac-[Mn(CO)3(Phen)(H2O)][CF3SO3] () are reported. A two order-of-magnitude of activation for the methanol substitution is induced as manifested by the second order rate constants with (N,N'-Bid) < (N,O-Bid). Forward and reverse rate and stability constants from slow and stopped-flow UV/vis measurements (k1, M(-1) s(-1); k-1, s(-1); K1, M(-1)) for pyridine as entering nucleophile are as follows: fac-[Mn(CO)3(Phen)(CH3OH)](+) (2.39 ± 5) × 10(-3), (1.5 ± 0.3) × 10(-5), 159 ± 32; fac-[Mn(CO)3(2,4-QuinH)(CH3OH)] (4.5 ± 0.2), (4 ± 1) × 10(-2), 113 ± 29. Activation parameters (ΔH, kJ mol(-1); ΔS, J K(-1) mol(-1)) from Eyring plots for entering nucleophiles as indicated are as follows: fac-[Mn(CO)3(Phen)(CH3OH)](+) (bromide ions) 66.7 ± 0.6, -27 ± 2; (pyridine) 80 ± 3, -25 ± 11; fac-[Mn(CO)3(Pico)(CH3OH)] (bromide ions) 68 ± 2, -24 ± 5. A dissociative interchange mechanism is proposed.
Friction, wear, and lubrication in vacuum
NASA Technical Reports Server (NTRS)
Buckley, D. H.
1971-01-01
A review of studies and observations on the friction, wear, and lubrication behavior of materials in a vacuum environment is presented. The factors that determine and influence friction and wear are discussed. They include topographical, physical, mechanical, and the chemical nature of the surface. The effects of bulk properties such as deformation characteristics, fracture behavior, and structure are included.
Improvement of wear resistance of plasma-sprayed molybdenum blend coatings
NASA Astrophysics Data System (ADS)
Ahn, Jeehoon; Hwang, Byoungchul; Lee, Sunghak
2005-06-01
The wear resistance of plasma sprayed molybdenum blend coatings applicable to synchronizer rings or piston rings was investigated in this study. Four spray powders, one of which was pure molybdenum and the others blended powders of bronze and aluminum-silicon alloy powders mixed with molybdenum powders, were sprayed on a low-carbon steel substrate by atmospheric plasma spraying. Microstructural analysis of the coatings showed that the phases formed during spraying were relatively homogeneously distributed in the molybdenum matrix. The wear test results revealed that the wear rate of all the coatings increased with increasing wear load and that the blended coatings exhibited better wear resistance than the pure molybdenum coating, although the hardness was lower. In the pure molybdenum coatings, splats were readily fractured, or cracks were initiated between splats under high wear loads, thereby leading to the decrease in wear resistance. On the other hand, the molybdenum coating blended with bronze and aluminum-silicon alloy powders exhibited excellent wear resistance because hard phases such as CuAl2 and Cu9Al4 formed inside the coating.
Erosive and Mechanical Tooth Wear in Viking Age Icelanders.
Richter, Svend; Eliasson, Sigfus Thor
2017-08-29
(1) Background: The importance of the Icelandic Sagas as a source of information about diet habits in medieval Iceland, and possibly other Nordic countries, is obvious. Extensive tooth wear in archaeological material worldwide has revealed that the main cause of this wear is believed to have been a coarse diet. Near the volcano Hekla, 66 skeletons dated from before 1104 were excavated, and 49 skulls could be evaluated for tooth wear. The purpose of this study was to determine the main causes of tooth wear in light of diet and beverage consumption described in the Sagas; (2) Materials and methods: Two methods were used to evaluate tooth wear and seven for age estimation; (3) Results: Extensive tooth wear was seen in all of the groups, increasing with age. The first molars had the highest score, with no difference between sexes. These had all the similarities seen in wear from a coarse diet, but also presented with characteristics that are seen in erosion in modern Icelanders, through consuming excessive amounts of soft drinks. According to the Sagas, acidic whey was a daily drink and was used for the preservation of food in Iceland, until fairly recently; (4) Conclusions: It is postulated that the consumption of acidic drinks and food, in addition to a coarse and rough diet, played a significant role in the dental wear seen in ancient Icelanders.
Erosive and Mechanical Tooth Wear in Viking Age Icelanders
Eliasson, Sigfus Thor
2017-01-01
(1) Background: The importance of the Icelandic Sagas as a source of information about diet habits in medieval Iceland, and possibly other Nordic countries, is obvious. Extensive tooth wear in archaeological material worldwide has revealed that the main cause of this wear is believed to have been a coarse diet. Near the volcano Hekla, 66 skeletons dated from before 1104 were excavated, and 49 skulls could be evaluated for tooth wear. The purpose of this study was to determine the main causes of tooth wear in light of diet and beverage consumption described in the Sagas; (2) Materials and methods: Two methods were used to evaluate tooth wear and seven for age estimation; (3) Results: Extensive tooth wear was seen in all of the groups, increasing with age. The first molars had the highest score, with no difference between sexes. These had all the similarities seen in wear from a coarse diet, but also presented with characteristics that are seen in erosion in modern Icelanders, through consuming excessive amounts of soft drinks. According to the Sagas, acidic whey was a daily drink and was used for the preservation of food in Iceland, until fairly recently; (4) Conclusions: It is postulated that the consumption of acidic drinks and food, in addition to a coarse and rough diet, played a significant role in the dental wear seen in ancient Icelanders. PMID:29563430
The effect of accelerated aging on the wear of UHMWPE.
Sakoda, H; Fisher, J; Lu, S; Buchanan, F
2001-01-01
Oxidative degradation of UHMWPE has been found to be a cause of elevated wear rate of the polymer in total joint replacement leading to failure of these devices. In order to evaluate long term stability of polymers, various accelerated aging methods have been developed. In this study, wear rates of shelf aged UHMWPE and "accelerated aged" UHMWPE were compared using a multi-directional pin-on-plate wear test machine in order to evaluate the effect of the accelerated aging on wear. Wear factors of the aged materials were found to depend on their density, which is a measure of oxidation level. Finally, accelerated aging was calibrated against shelf aging in terms of wear rate. Copyright 2001 Kluwer Academic Publishers
Medical Problems of Wearing a Coalminer's Safety Helmet
Fernandez, R. H. P.
1964-01-01
A survey of 324 men, who voluntarily reported an injury to that part of the head normally covered by a miner's safety helmet, took place at 18 collieries (16,732 men) during the period March 31 to September 30, 1962. The most prevalent site for injury was the top of the head in surface workers, and the forehead in underground workers. Normally surface workers do not wear a helmet. Underground workers expose their forehead when they wear their safety helmets in an upwards-tilted position. One reason for this practice is that the helmet has become too small due to shrinkage of the sweat-dampened leather headband which occurs after the helmet has been left for some time in the hot pit-head bath lockers. A helmet which had a wide, unshrinkable, easily adjustable headband made of smooth material was worn by 31 men who had dermatitis or soreness of that part of the skin normally covered by a safety helmet. After six months 26 of these men had no signs or symptoms, confirming that the main cause of helmet dermatitis is friction. A direct relationship between skin rash and sweating was observed in only four of these men. Images PMID:14142522
NASA Astrophysics Data System (ADS)
Ghosh, Debashis; Mallik, Manab; Mandal, Nilrudra; Dutta, Samik; Roy, Himadri; Lohar, Aditya Kumar
2017-04-01
This investigation was primarily carried out to examine the abrasive wear behavior of as cast Al-4.5 % Cu alloy. Wear tests have been carried out using an abrasive wear machine with emery paper embedded with SiC particles acting as abrasive medium. The experiments were planned using central composite design, with, load, cycle and grit size as input variables, whereas wear rate and 3D roughness were considered as output variable. Analysis of variance was applied to check the adequacy of the mathematical model and their respective parameters. Microstructural investigations of the worn surfaces have been carried out to explain the observed results and to understand the wear micro-mechanisms as per the planned experiments. Desirability function optimization technique was finally employed to optimize the controlling factors. The observed results revealed that, grit size plays a significant role in the variation of wear rate and 3D roughness as compared to load and cycles. Based on the significance of interactions, the regression equations were derived and verified further with a number of confirmation runs to assess the adequacy of the model. A close agreement (±10 %) between the predicted and experimentally measured results was obtained from this investigation.
Fretting Wear of Ti-48Al-2Cr-2Nb
NASA Technical Reports Server (NTRS)
Miyoshi, Kazuhisa; Lerch, Bradley A.; Draper, Susan L.
2001-01-01
An investigation was conducted to examine the wear behavior of gamma titanium aluminide (Ti-48Al-2Cr-2Nb in atomic percent) in contact with a typical nickel-base superalloy under repeated microscopic vibratory motion in air at temperatures from 296-823 K. The surface damage observed on the interacting surfaces of both Ti-48Al-2Cr-2Nb and superalloy consisted of fracture pits, oxides, metallic debris, scratches, craters, plastic deformation, and cracks. The Ti-48Al-2Cr-2Nb transferred to the superalloy at all fretting conditions and caused scuffing or galling. The increasing rate of oxidation at elevated temperatures led to a drop in Ti-48Al-2Cr-2Nb wear at 473 K. Mild oxidative wear was observed at 473 K. However, fretting wear increased as the temperature was increased from 473-823 K. At 723 and 823 K, oxide disruption generated cracks, loose wear debris, and pits on the Ti-48Al-2Cr-2Nb wear surface. Ti-48Al-2Cr-2Nb wear generally decreased with increasing fretting frequency. Both increasing slip amplitude and increasing load tended to produce more metallic wear debris, causing severe abrasive wear in the contacting metals. Keywords
Degradation of experimental composite materials and in vitro wear simulation
NASA Astrophysics Data System (ADS)
Givan, Daniel Allen
2001-12-01
The material, mechanical, and clinical aspects of surface degradation of resin composite dental restorative materials by in vitro wear simulation continues to be an area of active research. To investigate wear mechanisms, a series of experimental resin composites with variable and controlled filler particle shape and loading were studied by in vitro wear simulation. The current investigation utilized a simulation that isolated the wear environment, entrapped high and low modulus debris, and evaluated the process including machine and fluid flow dynamics. The degradation was significantly affected by filler particle shape and less by particle loading. The spherical particle composites demonstrated wear loss profiles suggesting an optimized filler loading may exist. This was also demonstrated by the trends in the mechanical properties. Very little difference in magnitude was noted for the wear of irregular particle composites as a function of particulate size; and as a group they were more wear resistant than spherical particle composites. This was the result of different mechanisms of wear that were correlated with the three-dimensional particle shape. The abrasive effects of the aggregate particles and the polymeric stabilization of the irregular shape versus the destabilization and "plucking" of the spherical particles resulted in an unprotected matrix that accounted for significantly greater wear of spherical composite. A model and analysis was developed to explain the events associated with the progressive material wear loss. The initial phase was explained by fatigue-assisted microcracking and loss of material segments in a zone of high stress immediately beneath a point of high stress contact. The early phase was characterized by the development of a small facet primarily by fatigue-assisted microcracking. Although the translation effects were minimal, some three-body and initial two-body wear events were also present. In the late phases, the abrasive effects
Morais, Maurício; Subramanian, Suresh; Pandey, Usha; Samuel, Grace; Venkatesh, Meera; Martins, Manuel; Pereira, Sérgio; Correia, João D G; Santos, Isabel
2011-04-04
Despite being widely used in the clinical setting for sentinel lymph node detection (SLND), (99m)Tc-based colloids (e.g., (99m)Tc-human serum albumin colloids) present a set of properties that are far from ideal. Aiming to design novel compounds with improved biological properties, we describe herein the first class of fully characterized (99m)Tc(CO)₃-mannosylated dextran derivatives with adequate features for SLND. Dextran derivatives, containing the same number of pendant mannose units (13) and a variable number (n) of tridentate chelators (9, n = 1; 10, n = 4, 11, n= 12), have been synthesized and fully characterized. Radiolabeled polymers of the type fac-[(99m)Tc(CO)₃(k³-L)] (12, L = 9, 13, L = 10, 14, L = 11) have been obtained quantitatively in high radiochemical purity (≥ 98%) upon reaction of the dextran derivatives with fac-[(99m)Tc(CO)₃(H₂O)₃]+. The highly stable compounds 13 and 14 were identified by comparing their HPLC chromatograms with the ones obtained for the corresponding rhenium surrogates fac-[Re(CO)₃(k³-10)] (13a) and fac-[Re(CO)₃(k³-11)] (14a), which have been characterized both at the chemical (NMR and IR spectroscopy, and HPLC) and physical level (DLS, AFM and LDV). Compounds 13a and 14a present a positive zeta potential (+ 7.1 mV, pH 7.4) and a hydrodynamic diameter in the range 8.4-8.7 nm. Scintigraphic imaging and biodistribution studies in Wistar rats have shown good accumulation in the sentinel node at 60 min postinjection (6.71 ± 2.35%, 13; and 7.53 ± 0.69%, 14), with significant retention up to 180 min. A clear delineation of the sentinel lymph node without significant washout to other regions was observed in the scintigraphic images. The popliteal extraction of 94.47 ± 2.45% for 14 at 1 h postinjection, as compared to 61.81 ± 2.4% for 13, indicated that 14 is a very promising compound to be further explored as SLN imaging agent.
2005 survey of seat belt wearing rates
DOT National Transportation Integrated Search
2005-01-01
The 2005 seat belt survey showed a minor improvement in driver wearing : rates. Over the 2003 2005 period, estimated wearing rates for male drivers : increased by one percentage point to 83 per cent, and for female drivers : increased by two perc...
[Patients' reaction to pharmacists wearing a mask during their consultations].
Tamura, Eri; Kishimoto, Keiko; Fukushima, Noriko
2013-01-01
This study sought to determine the effect of pharmacists wearing a mask on the consultation intention of patients who do not have a trusting relationship with the pharmacists. We conducted a questionnaire survey of customers at a Tokyo drugstore in August 2012. Subjects answered a questionnaire after watching two medical teaching videos, one in which the pharmacist was wearing a mask and the other in which the pharmacist was not wearing a mask. Data analysis was performed using a paired t-test and multiple logistic regression. The paired t-test revealed a significant difference in 'Maintenance Problem' between the two pharmacist situations. After excluding factors not associated with wearing a mask, multiple logistic regression analysis identified three independent variables with a significant effect on participants not wanting to consult with a pharmacist wearing a mask. Positive factors were 'active-inactive' and 'frequency mask use', a negative factor was 'age'. Our study has shown that pharmacists wearing a mask may be a factor that prevents patients from consulting with pharmacist. Those patients whose intention to consult might be affected by the pharmacists wearing a mask tended to be younger, to have no habit of wearing masks preventively themselves, and to form a negative opinion of such pharmacists. Therefore, it was estimated that pharmacists who wear masks need to provide medical education by asking questions more positively than when they do not wear a mask in order to prevent the patient worrying about oneself.
Kang, Lu; Galvin, Alison L.; Brown, Thomas D.; Jin, Zhongmin; Fisher, John
2008-01-01
A computational model has been developed to quantify the degree of cross-shear of a polyethylene pin articulating against a metallic plate, based on the direct simulation of a multidirectional pin-on-plate wear machine. The principal molecular orientation (PMO) was determined for each polymer site. The frictional work in the direction perpendicular to the PMO was assumed to produce the greatest orientation softening (Wang et al., 1997). The cross-shear ratio (CS) was defined as the frictional work perpendicular to the PMO direction, divided by the total frictional work. Cross-shear on the pin contact surface was location-specific, and of continuously changing magnitude because the direction of frictional force continuously changed due to pin rotation. The polymer pin motion was varied from a purely linear track (CS=0) up to a maximum rotation of ±55° (CS=0.254). The relationship between wear factors (K) measured experimentally and theoretically predicted CS was defined using logarithmic functions for both conventional and highly cross-linked UHMWPE. Cross-shear increased the apparent wear factor for both polyethylenes by more than 5-fold compared to unidirectional wear. PMID:17936763
Goodman, S. B.; Gibon, E.; Pajarinen, J.; Lin, T.-H.; Keeney, M.; Ren, P.-G.; Nich, C.; Yao, Z.; Egashira, K.; Yang, F.; Konttinen, Y. T.
2014-01-01
Wear particles and by-products from joint replacements and other orthopaedic implants may result in a local chronic inflammatory and foreign body reaction. This may lead to persistent synovitis resulting in joint pain and swelling, periprosthetic osteolysis, implant loosening and pathologic fracture. Strategies to modulate the adverse effects of wear debris may improve the function and longevity of joint replacements and other orthopaedic implants, potentially delaying or avoiding complex revision surgical procedures. Three novel biological strategies to mitigate the chronic inflammatory reaction to orthopaedic wear particles are reported. These include (i) interference with systemic macrophage trafficking to the local implant site, (ii) modulation of macrophages from an M1 (pro-inflammatory) to an M2 (anti-inflammatory, pro-tissue healing) phenotype in the periprosthetic tissues, and (iii) local inhibition of the transcription factor nuclear factor kappa B (NF-κB) by delivery of an NF-κB decoy oligodeoxynucleotide, thereby interfering with the production of pro-inflammatory mediators. These three approaches have been shown to be viable strategies for mitigating the undesirable effects of wear particles in preclinical studies. Targeted local delivery of specific biologics may potentially extend the lifetime of orthopaedic implants. PMID:24478281
ERIC Educational Resources Information Center
Howard, Erica
2011-01-01
Written in accessible language, Law and the Wearing of Religious Symbols is a comprehensive analysis of a topical subject that is being widely debated across Europe. The book provides an overview of emerging case law from the European Court of Human Rights as well as from national courts and equality bodies in European countries on the wearing of…
Fractal characteristic in the wearing of cutting tool
NASA Astrophysics Data System (ADS)
Mei, Anhua; Wang, Jinghui
1995-11-01
This paper studies the cutting tool wear with fractal geometry. The wearing image of the flank has been collected by machine vision which consists of CCD camera and personal computer. After being processed by means of preserving smoothing, binary making and edge extracting, the clear boundary enclosing the worn area has been obtained. The fractal dimension of the worn surface is calculated by the methods called `Slit Island' and `Profile'. The experiments and calciating give the conclusion that the worn surface is enclosed by a irregular boundary curve with some fractal dimension and characteristics of self-similarity. Furthermore, the relation between the cutting velocity and the fractal dimension of the worn region has been submitted. This paper presents a series of methods for processing and analyzing the fractal information in the blank wear, which can be applied to research the projective relation between the fractal structure and the wear state, and establish the fractal model of the cutting tool wear.
Extensive Bone Reaction From Catastrophic Oxidized Zirconium Wear.
Cassar-Gheiti, Adrian J; Collins, Dennis; McCarthy, Tom
2016-01-01
The use of alternative bearing surfaces for total hip arthroplasty has become popular to minimize wear and increase longevity, especially in young patients. Oxidized zirconium (Oxinium; Smith & Nephew, Memphis, Tennessee) femoral heads were introduced in the past decade for use in total hip arthroplasty. The advantages of oxidized zirconium include less risk of fracture compared with traditional ceramic heads. This case report describes a patient with a history of bilateral avascular necrosis of the femoral head after chemotherapy for acute lymphoblastic leukemia. Nonoperative management of avascular necrosis failed, and the patient was treated with bilateral total hip arthroplasty. The patient was followed at regular intervals and had slow eccentric polyethylene wear during a 10-year period. After 10 years, the patient had accelerated wear, with femoral and acetabular bone changes as a result of Oxinium and ultrahigh-molecular-weight polyethylene wear during a 6-month period. This article highlights the unusual accelerated bone changes that occurred as a result of Oxinium wear particles. Copyright 2016, SLACK Incorporated.
A study of the wear behaviour of ion implanted pure iron
NASA Astrophysics Data System (ADS)
Goode, P. D.; Peacock, A. T.; Asher, J.
1983-05-01
The technique of Thin Layer Activation (TLA) has been used to monitor disc wear in pin-on-disc wear tests. By simultaneously monitoring the pin wear the relationship between the wear rates of the two components of the wear couple has been studied. Tests were carried out using untreated pins wearing against ion implanted and untreated pure iron discs. The ratio of pin/disc volumetric wear rates was found to be constant in tests with unimplanted discs. In the implanted case the ratio was 8 initially, rising to the unimplatned value of 24 by a sliding distance of 25 km. The relationship between pin and disc wear after nitrogen implantation of the disc was approximately independent of dose between values of 7×10 16 and 1.2×10 18 N atoms cm -2. The actual wear rates of both pin and disc were significantly lower after implantation with the greater effects being observed om the unimplanted pin. The effects are explained in terms of the model of oxidative wear. In the unimplanted case the high pin wear relative to disc wear is considered to result from the higher mean temperature of pin asperities. Implantation appears to alter the mean asperity temperatures in such a way as to reduce the oxidation rate of the pin preferentially. Alternatively the effect of the implantation could be to reduce the critical thickness for removal of oxide formed on disc asperities.
Hatam, N; Ahmadloo, N; Ahmad Kia Daliri, A; Bastani, P; Askarian, M
2011-07-01
The aim of this study was to compare two regimens of chemotherapy in patients with breast cancer, including FAC (doxorubicin, cyclophosphamide, and 5-fluorouracil) and TAC (docetaxel, doxorubicin and cyclophosphamide); and analyze the toxicity of these treatments and observe patient's health-related quality of life. Health-related quality of life was assessed for up to 4 months (from the beginning to the end of chemotherapy cycles), using European organization and cancer treatment quality of life questionnaire (EORTC) QLQ-C30. A group of 100 patients, with node-positive breast cancer were studied in order to compare the toxicity of adjuvant therapy TAC with FAC and the subsequent effects on the patient's quality of life. After a 4-month follow-up of patients, our findings showed that despite having the same mean score of QOL at the start of adjuvant chemotherapy, the QOL in TAC arm was decreased more as a result of the higher range of toxicity in TAC regimen. In spite of increase in disease-free patients who received TAC regimen and increase their survival rate, there is significant toxicity and decrease in QOL in TAC protocol compare to FAC protocol. Using prophylactic granulocyte colony stimulating factor (G-CSF) along with increased education aimed at improving patient's knowledge and also the provision of a supportive group involving psychiatrics and patients that have successfully experienced the same treatment may be helpful.
Astronaut Bonnie Dunbar wearing extravehicular mobility unit
NASA Technical Reports Server (NTRS)
1985-01-01
Astronaut Bonnie J. Dunbar, wearing an extravehicular mobility unit (EMU), is about to be submerged in the weightless environment training facility (WETF) to simulate a contingency extravehicular activity (EVA) for STS 61-A. In this portrait view, Dunbar is not wearing a helmet.
Impact wear behavior of human tooth enamel under simulated chewing conditions.
Zheng, Jing; Zeng, Yangyang; Wen, Jian; Zheng, Liang; Zhou, Zhongrong
2016-09-01
Previous studies mostly focused on the sliding wear behavior of human teeth, and little effort has been made so far to study the impact wear of human teeth. The objective of this study was to investigate the impact wear process and mechanism of human tooth enamel and the influence of water content within enamel. In this paper, the impact wear behaviors of fresh and dried human tooth enamel against SiC ceramic have been investigated using a specially designed impact test machine. Tests lasting up to 5×10(3), 5×10(4), 2.5×10(5), 5.5×10(5), 8×10(5) and 1×10(6) cycles were conducted, respectively. Results showed that for the fresh enamel, the surface damage was dominated by plastic deformation at the early stage of impact wear. Iridescent rings appeared around the impact mark as a result of the accumulation and spread of plastic deformation. As the impact wear progressed, delamination occurred on the surface of enamel, and thus the iridescent rings gradually disappeared. Wear loss increased rapidly with the increase of impact cycles. When a wear particle layer was formed on the enamel surface, the wear rate decreased. It was found that the surface hardness of enamel increased with the impact cycles, and no cracks appeared on the cross section of wear scar. Compared with the fresh enamel, the fracture toughness of dried enamel decreased, and thus there were microcracks appearing on the cross section of wear scar. More obvious delamination occurred on the worn surface of dried enamel, and no iridescent rings were observed. The wear loss of dried enamel was higher than that of fresh enamel. In summary, the impact wear behavior of sound human tooth enamel was metal-like to some degree, and no subsurface cracking occurred. The water content within enamel could increase its fracture toughness and protect the surface from impact wear. The wear mechanism of human tooth enamel is determined by its microstructure. Copyright © 2016 Elsevier Ltd. All rights reserved.
Evolution of wear and friction along experimental faults
Boneh, Yeval; Chang, Jefferson C.; Lockner, David A.; Reches, Zeev
2014-01-01
We investigate the evolution of wear and friction along experimental faults composed of solid rock blocks. This evolution is analyzed through shear experiments along five rock types, and the experiments were conducted in a rotary apparatus at slip velocities of 0.002–0.97 m/s, slip distances from a few millimeters to tens of meters, and normal stress of 0.25–6.9 MPa. The wear and friction measurements and fault surface observations revealed three evolution phases: A) An initial stage (slip distances <50 mm) of wear by failure of isolated asperities associated with roughening of the fault surface; B) a running-in stage of slip distances of 1–3 m with intense wear-rate, failure of many asperities, and simultaneous reduction of the friction coefficient and wear-rate; and C) a steady-state stage that initiates when the fault surface is covered by a gouge layer, and during which both wear-rate and friction coefficient maintain quasi-constant, low levels. While these evolution stages are clearly recognizable for experimental faults made from bare rock blocks, our analysis suggests that natural faults “bypass” the first two stages and slip at gouge-controlled steady-state conditions.
NASA Astrophysics Data System (ADS)
Poley, Jack; Dines, Michael
2011-04-01
Wind turbines are frequently located in remote, hard-to-reach locations, making it difficult to apply traditional oil analysis sampling of the machine's critical gearset at timely intervals. Metal detection sensors are excellent candidates for sensors designed to monitor machine condition in vivo. Remotely sited components, such as wind turbines, therefore, can be comfortably monitored from a distance. Online sensor technology has come of age with products now capable of identifying onset of wear in time to avoid or mitigate failure. Online oil analysis is now viable, and can be integrated with onsite testing to vet sensor alarms, as well as traditional oil analysis, as furnished by offsite laboratories. Controlled laboratory research data were gathered from tests conducted on a typical wind turbine gearbox, wherein total ferrous particle measurement and metallic particle counting were employed and monitored. The results were then compared with a physical inspection for wear experienced by the gearset. The efficacy of results discussed herein strongly suggests the viability of metallic wear debris sensors in today's wind turbine gearsets, as correlation between sensor data and machine trauma were very good. By extension, similar components and settings would also seem amenable to wear particle sensor monitoring. To our knowledge no experiments such as described herein, have previously been conducted and published.
Wear Behavior of an Unstable Knee: Stabilization via Implant Design?
Reinders, Jörn; Kretzer, Jan Philippe
2014-01-01
Background. Wear-related failures and instabilities are frequent failure mechanisms of total knee replacements. High-conforming designs may provide additional stability for the joint. This study analyzes the effects of a ligamentous insufficiency on the stability and the wear behavior of a high-conforming knee design. Methods. Two simulator wear tests were performed on a high-conforming total knee replacement design. In the first, a ligamentous-stable knee replacement with a sacrificed anterior cruciate ligament was simulated. In the second, a ligamentous-unstable knee with additionally insufficient posterior cruciate ligament and medial collateral ligament was simulated. Wear was determined gravimetrically and wear particles were analyzed. Implant kinematics was recorded during simulation. Results. Significantly higher wear rates (P ≤ 0.001) were observed for the unstable knee (14.58 ± 0.56 mg/106 cycles) compared to the stable knee (7.97 ± 0.87 mg/106 cycles). A higher number of wear particles with only small differences in wear particle characteristics were observed. Under unstable knee conditions, kinematics increased significantly for translations and rotations (P ≤ 0.01). This increase was mainly attributed to higher tibial posterior translation and internal rotations. Conclusion. Higher kinematics under unstable test conditions is a result of insufficient stabilization via implant design. Due to the higher kinematics, increased wear was observed in this study. PMID:25276820
Study of Abrasive Wear Volume Map for PTFE and PTFE Composites
NASA Astrophysics Data System (ADS)
Unal, H.; Sen, U.; Mimaroglu, A.
2007-11-01
The potential of this work is based on consideration of wear volume map for the evaluation of abrasive wear performance of polytetrafluoroethylene (PTFE) and PTFE composites. The fillers used in the composite are 25% bronze, 35% graphite and 17% glass fibre glass (GFR). The influence of filler materials, abrasion surface roughness and applied load values on abrasive wear performance of PTFE and PTFE composites were studied and evaluated. Experimental abrasive wear tests were carried out at atmospheric condition on pin-on-disc wear tribometer. Tests were performed under 4, 6, 8 and 10 N load values, travelling speed of 1 m/sec and abrasion surface roughness values of 5, 20 and 45 µm. Wear volume maps were obtained and the results showed that the lowest wear volume rate for PTFE is reached using GFR filler. Furthermore, the results also showed that the higher is the applied load and the roughness of the abrasion surface, the higher is the wear rate. Finally it is also concluded that abrasive wear process mechanism include ploughing and cutting mechanisms.
Schutte, Marietjie; Kemp, Gerdus; Visser, Hendrik G; Roodt, Andreas
2011-12-19
A range of fac-[Re(CO)(3)(L,L'-Bid)(H(2)O)](n) (L,L'-Bid = neutral or monoanionic bidentate ligands with varied L,L' donor atoms, N,N', N,O, or O,O': 1,10-phenanthroline, 2,2'-bipydine, 2-picolinate, 2-quinolinate, 2,4-dipicolinate, 2,4-diquinolinate, tribromotropolonate, and hydroxyflavonate; n = 0, +1) has been synthesized and the aqua/methanol substitution has been investigated. The complexes were characterized by UV-vis, IR and NMR spectroscopy and X-ray crystallographic studies of the compounds fac-[Re(CO)(3)(Phen)(H(2)O)]NO(3)·0.5Phen, fac-[Re(CO)(3)(2,4-dQuinH)(H(2)O)]·H(2)O, fac-[Re(CO)(3)(2,4-dQuinH)Py]Py, and fac-[Re(CO)(3)(Flav)(CH(3)OH)]·CH(3)OH are reported. A four order-of-magnitude of activation for the methanol substitution is induced as manifested by the second order rate constants with (N,N'-Bid) < (N,O-Bid) < (O,O'-Bid). Forward and reverse rate and stability constants from slow and stopped-flow UV/vis measurements (k(1), M(-1) s(-1); k(-1), s(-1); K(1), M(-1)) for bromide anions as entering nucleophile are as follows: fac-[Re(CO)(3)(Phen)(MeOH)](+) (50 ± 3) × 10(-3), (5.9 ± 0.3) × 10(-4), 84 ± 7; fac-[Re(CO)(3)(2,4-dPicoH)(MeOH)] (15.7 ± 0.2) × 10(-3), (6.3 ± 0.8) × 10(-4), 25 ± 3; fac-[Re(CO)(3)(TropBr(3))(MeOH)] (7.06 ± 0.04) × 10(-2), (4 ± 1) × 10(-3), 18 ± 4; fac-[Re(CO)(3)(Flav)(MeOH)] 7.2 ± 0.3, 3.17 ± 0.09, 2.5 ± 2. Activation parameters (ΔH(k1)(++), kJmol(-1); ΔS(k1)(), J K(-1) mol(-1)) from Eyring plots for entering nucleophiles as indicated are as follows: fac-[Re(CO)(3)(Phen)(MeOH)](+) iodide 70 ± 1, -35 ± 3; fac-[Re(CO)(3)(2,4-dPico)(MeOH)] bromide 80.8 ± 6, -8 ± 2; fac-[Re(CO)(3)(Flav)(MeOH)] bromide 52 ± 5, -52 ± 15. A dissociative interchange mechanism is proposed. © 2011 American Chemical Society
Astronaut James Buchli wearing extravehicular mobility unit
NASA Technical Reports Server (NTRS)
1985-01-01
Astronaut James F. Buchli, wearing an extravehicular mobility unit (EMU), is about to be submerged in the weightless environment training facility (WETF) to simulate a contingency extravehicular activity (EVA) for STS 61-A. In this portrait view, Buchli is wearing a communications carrier assembly (CCA).
The Prevalence of Tooth Wear in the Dutch Adult Population
Wetselaar, Peter; Vermaire, Jan H.; Visscher, Corine M.; Lobbezoo, Frank; Schuller, Annemarie A.
2016-01-01
This study aimed to assess the prevalence of tooth wear in different age groups of the Dutch adult population and to determine this tooth wear distribution by gender, socioeconomic class, and type of teeth. Results were compared with the outcomes of a previous study in a comparable population. As part of a comprehensive investigation of the oral health of the general Dutch adult population in 2013, tooth wear was assessed among 1,125 subjects in the city of ‘s-Hertogenbosch. The data collected were subjected to stratified analysis by 5 age groups (25-34, 35-44, 45-54, 55-64, and 65-74 years), gender, socioeconomic class, and type of teeth. Tooth wear was assessed using a 5-point ordinal occlusal/incisal grading scale. The number of teeth affected was higher in older age groups. Men showed more tooth wear than women, and subjects with low socioeconomic status (low SES) showed on average higher scores than those with high SES. Tooth wear prevalence found in this study was higher in all age groups than in the previous study. The present study found prevalences of 13% for mild tooth wear and 80% for moderate tooth wear, leading to the conclusion that these are common conditions in the Dutch adult population. Severe tooth wear (prevalence 6%) may however be characterized as rare. A tendency was found for there to be more tooth wear in older age groups, in men as compared with women, in persons with lower SES, and in the present survey as compared with the previous one. PMID:27694757
The Prevalence of Tooth Wear in the Dutch Adult Population.
Wetselaar, Peter; Vermaire, Jan H; Visscher, Corine M; Lobbezoo, Frank; Schuller, Annemarie A
2016-01-01
This study aimed to assess the prevalence of tooth wear in different age groups of the Dutch adult population and to determine this tooth wear distribution by gender, socioeconomic class, and type of teeth. Results were compared with the outcomes of a previous study in a comparable population. As part of a comprehensive investigation of the oral health of the general Dutch adult population in 2013, tooth wear was assessed among 1,125 subjects in the city of 's-Hertogenbosch. The data collected were subjected to stratified analysis by 5 age groups (25-34, 35-44, 45-54, 55-64, and 65-74 years), gender, socioeconomic class, and type of teeth. Tooth wear was assessed using a 5-point ordinal occlusal/incisal grading scale. The number of teeth affected was higher in older age groups. Men showed more tooth wear than women, and subjects with low socioeconomic status (low SES) showed on average higher scores than those with high SES. Tooth wear prevalence found in this study was higher in all age groups than in the previous study. The present study found prevalences of 13% for mild tooth wear and 80% for moderate tooth wear, leading to the conclusion that these are common conditions in the Dutch adult population. Severe tooth wear (prevalence 6%) may however be characterized as rare. A tendency was found for there to be more tooth wear in older age groups, in men as compared with women, in persons with lower SES, and in the present survey as compared with the previous one. © 2016 S. Karger AG, Basel.
Wear-Out Sensitivity Analysis Project Abstract
NASA Technical Reports Server (NTRS)
Harris, Adam
2015-01-01
During the course of the Summer 2015 internship session, I worked in the Reliability and Maintainability group of the ISS Safety and Mission Assurance department. My project was a statistical analysis of how sensitive ORU's (Orbital Replacement Units) are to a reliability parameter called the wear-out characteristic. The intended goal of this was to determine a worst case scenario of how many spares would be needed if multiple systems started exhibiting wear-out characteristics simultaneously. The goal was also to determine which parts would be most likely to do so. In order to do this, my duties were to take historical data of operational times and failure times of these ORU's and use them to build predictive models of failure using probability distribution functions, mainly the Weibull distribution. Then, I ran Monte Carlo Simulations to see how an entire population of these components would perform. From here, my final duty was to vary the wear-out characteristic from the intrinsic value, to extremely high wear-out values and determine how much the probability of sufficiency of the population would shift. This was done for around 30 different ORU populations on board the ISS.
Wear of Selected Oxide Ceramics and Coatings
NASA Technical Reports Server (NTRS)
Miyoshi, K.; Sayir, A.; Farmer, S. C.
2005-01-01
The use of oxide ceramics and coatings for moving mechanical components operating in high-temperature, oxidizing environments creates a need to define the tribological performance and durability of these materials. Results of research focusing on the wear behavior and properties of Al2O3/ZrO2 (Y2O3) eutectics and coatings under dry sliding conditions are discussed. The importance of microstructure and composition on wear properties of directionally solidified oxide eutectics is illustrated. Wear data of selected oxide-, nitride-, and carbide-based ceramics and coatings are given for temperatures up to 973K in air.
A hip wear simulator with 100 test stations.
Saikko, V
2005-09-01
A novel high-capacity hip wear simulator of the pin-on-disc type was designed, built, and validated. This so-called Super-CTPOD (circularly translating pin-on-disc) device has as many as 100 separate test stations, being an advanced version of the previously validated 12-station CTPOD. A validity test was done so that in all stations the specimens and the test conditions were as similar as possible. Hence, for the first time in this field, an adequate number of similar tests was done for a proper statistical analysis of wear data. The pins were conventional, gamma-sterilized ultra-high molecular weight polyethylene, and the discs were polished CoCr. The lubricant was diluted calf serum and the test length 3 million cycles. In the course of the test, the pins became highly polished, whereas the discs remained practically unchanged. The majority of the polyethylene wear particles were rounded, with a mean diameter of 0.25 microm. The 100 wear factor values computed from the 100 steady state wear rate values of the pins were normally distributed, the mean +/- 95 per cent confidence interval being 1.63 +/- 0.017 x 10(-6) mm3 /N m. The standard deviation was 5.4 per cent of the mean. There were no outliers. The wear mechanisms and the wear factor agreed well with clinical findings. Altogether, the Super-CTPOD test system was shown to be a unique combination of validity, low variation, capacity, efficiency, reliability, productivity, economy, ease of operation, and compact size.
Adhesive and abrasive wear mechanisms in ion implanted metals
NASA Astrophysics Data System (ADS)
Dearnaley, G.
1985-03-01
The distinction between adhesive and abrasive wear processes was introduced originally by Burwell during the nineteen-fifties, though some authors prefer to classify wear according to whether it is mild or severe. It is argued here that, on the basis of the performance of a variety of ion implanted metal surfaces, exposed to different modes of wear, the Burwell distinction is a valid one which, moreover, enables us to predict under which circumstances a given treatment will perform well. It is shown that, because wear rates under abrasive conditions are very sensitive to the ratio of the hardness of the surface to that of the abrasive particles, large increases in working life are attainable as a result of ion implantation. Under adhesive wear conditions, the wear rate appears to fall inversely as the hardness increases, and it is advantageous to implant species which will create and retain a hard surface oxide or other continuous film in order to reduce metal-metal contact. By the appropriate combination of physico-chemical changes in an implanted layer it has been possible to reduce wear rates by up to three orders of magnitude. Such rates compensate for the shallow depths achievable by ion implantation.
Sliding wear and friction behaviour of zircaloy-4 in water
NASA Astrophysics Data System (ADS)
Sharma, Garima; Limaye, P. K.; Jadhav, D. T.
2009-11-01
In water cooled nuclear reactors, the sliding of fuel bundles in fuel channel handling system can lead to severe wear and it is an important topic to study. In the present study, sliding wear behaviour of zircaloy-4 was investigated in water (pH ˜ 10.5) using ball-on-plate sliding wear tester. Sliding wear resistance zircaloy-4 against SS 316 was examined at room temperature. Sliding wear tests were carried out at different load and sliding frequencies. The coefficient of friction of zircaloy-4 was also measured during each tests and it was found to decrease slightly with the increase in applied load. The micro-mechanisms responsible for wear in zircaloy-4 were identified to be microcutting, micropitting and microcracking of deformed subsurface zones in water.
New Oxide Ceramic Developed for Superior High-Temperature Wear Resistance
NASA Technical Reports Server (NTRS)
Sayir, Ali; Miyoshi, Kazuhisa; Farmer, Serene C.
2003-01-01
Ceramics, for the most part, do not have inherently good tribological properties. For example friction coefficients in excess of 0.7 have been reported for silicon nitride sliding on silicon nitride or on bearing steel (ref. 1). High friction is always accompanied by considerable wear. Despite their inherently poor tribological properties, the high strength and high toughness of silicon nitride (Si3N4) ceramics has led to their successful use in tribological applications (refs. 1 to 4). The upper temperature limit for the application of Si3N4 as wear-resistant material is limited by reaction with the tribological environment (ref. 3). Silicon nitride is known to produce a thin silicon dioxide film with easy shear capability that results in low friction and low wear in a moist environment (ref. 5). At elevated temperatures, the removal of the reaction product that acts as lubricant causes the friction coefficient to increase and, consequently, the wear performance to become poor. New materials are sought that will have wear resistance superior to that of Si3N4 at elevated temperatures and in harsh environments. A new class of oxide ceramic materials has been developed with potential for excellent high-temperature wear resistance. The new material consists of a multicomponent oxide with a two-phase microstructure, in which the wear resistance of the mixed oxide is significantly higher than that of the individual constituents. This is attributed to the strong constraining effects provided by the interlocking microstructures at different length scales, to the large aspect ratio of the phases, to the strong interphase bonding, and to the residual stresses. Fretting wear tests were conducted by rubbing the new ceramic material against boron carbide (B4C). The new ceramic material produced a wear track groove on B4C, suggesting significantly higher wear resistance for the oxide ceramic. The new material did not suffer from any microstructural degradation after the wear
Ferrographic analysis of wear debris generated in a sliding elastohydrodynamic contact
NASA Technical Reports Server (NTRS)
Jones, W. R., Jr.; Nagaraj, H. S.; Winer, W. O.
1977-01-01
The ferrograph was used to analyze wear debris generated in a sliding elastohydrodynamic contact. The amount of wear debris correlates well with the ratio of film thickness to composite surface roughness. Essentially all of the generated wear particles were of the normal rubbing wear type.
Characterization and measurement of polymer wear
NASA Technical Reports Server (NTRS)
Buckley, D. H.; Aron, P. R.
1984-01-01
Analytical tools which characterize the polymer wear process are discussed. The devices discussed include: visual observation of polymer wear with SEM, the quantification with surface profilometry and ellipsometry, to study the chemistry with AES, XPS and SIMS, to establish interfacial polymer orientation and accordingly bonding with QUARTIR, polymer state with Raman spectroscopy and stresses that develop in polymer films using a X-ray double crystal camera technique.
Wear consideration in gear design for space applications
NASA Technical Reports Server (NTRS)
Akin, Lee S.; Townsend, Dennis P.
1989-01-01
A procedure is described that was developed for evaluating the wear in a set of gears in mesh under high load and low rotational speed. The method can be used for any low-speed gear application, with nearly negligible oil film thickness, and is especially useful in space stepping mechanism applications where determination of pointing error due to wear is important, such as in long life sensor antenna drives. A method is developed for total wear depth at the ends of the line of action using a very simple formula with the slide to roll ratio V sub s/V sub r. A method is also developed that uses the wear results to calculate the transmission error also known as pointing error of a gear mesh.
Study of wear performance of deep drawing tooling
NASA Astrophysics Data System (ADS)
Naranje, Vishal G.; Karthikeyan, Ram; Nair, Vipin
2017-09-01
One of the most common challenges for many of the mechanical engineers and also in the field of materials science is the issue of occurrences of wear of the material parts which is used in certain applications that involves such surface interactions. In this paper, wear behaviour of particular grade High Carbon High Chromium Steel and many most famously D2, H13, O1 known as the Viking steel has been studied, evaluated and analyzed under certain processing parameters such as speed, load, track diameter and time required for deep drawing process to know it’s the wear rate and coefficient of friction. Also, the significance of the processing parameters which is used for wear testing analysis is also examined.
Canine tooth wear in captive little brown bats
Clark, Donald R.
1980-01-01
Upper canine teeth of little brown bats Myotis lucifugus lucifugus held in stainless steel wire mesh cages underwent severe wear which exceeded that observed previously in caged big brown bats, Eptesicus fuscus fuscus. This suggests a relationship between amount of wear and size of the caged bats with damage increasing as size decreases. Rapid wear of canine teeth by little brown bats resembled that observed in big brown bats in that it was limited to the first 2 weeks of captivity. This result indicates a universal interval for acclimation to cage conditions among vespertilionid bats. Dietary toxicants DDE and PCB did not affect the extent of wear. If bats are to be released to the wild, confinement in wire mesh cages should be avoided.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Y.; Baer, C.D.; Camaioni-Neto, C.
1991-04-17
A new procedure is reported for the high-yield synthesis of fac-tris-ortho-metalated complexes of Ir(III) with 2-phenylpyridine (Hppy) and with substituted 2-phenylpyridine (R-Hppy) ligands. The reported procedure uses the Ir(III) starting material Ir(acac){sub 3} (acac = 2,4-pentanedionate) and typically produces the fac-tris-ortho-metalated complexes in yields of 40-75%. Each of the complexes formed with substituted phenylpyridines exhibited a luminescence lifetime of approximately 2-5 microseconds in nitrogen-saturated acetonitrile at room temperature, and each complex is characterized by a reversible oxidative wave in cyclic voltammetry in acetonitrile. 42 refs., 1 fig., 1 tab.
Potential sources of bacteria that are isolated from contact lenses during wear.
Willcox, M D; Power, K N; Stapleton, F; Leitch, C; Harmis, N; Sweeney, D F
1997-12-01
The aim of this paper was to determine the possible contamination sources of contact lenses during wear. Potential sources of the microbiota that colonized hydrogel contact lenses during wear were examined. The microorganisms that colonize contact lenses were grown, identified, and compared to those microorganisms that colonized the lower lid margins, upper bulbar conjunctiva, hands, and contact lens cases of contact lens wearers. In addition, the incidence of contamination of the domestic water supply in the Sydney area was obtained, and this was compared to the incidence of colonization of contact lenses by microorganisms in general and gram-negative bacteria in particular. There was a wide diversity of bacteria that were isolated from each site sampled. Coagulase-negative staphylococci and Propionibacterium spp. were the most common isolates from all ocular sites examined, and constituted the normal ocular microbiota. Other bacteria, including members of the families Enterobacteriaceae and Pseudomonadaceae, were isolated infrequently from all sites, but most frequently from contact lens cases. Statistical analysis revealed that there was a correlation between the isolation of bacteria from the contact lens and the lower lid margin (p < 0.001). Analysis of this correlation revealed that this was true for the normal microbiota. A correlation was also noted between the colonization of contact lenses by gram-negative bacteria and contamination of the domestic water supply. This study has demonstrated that the likely route for the normal ocular microbiota colonizing contact lenses is via the lid margins, whereas colonization by gram-negative bacteria, including potential agents of microbial keratitis, is likely to be from the domestic water supply.
Update on slip and wear in multi-layer azimuth track systems
NASA Astrophysics Data System (ADS)
Juneja, Gunjeet; Kan, Frank W.; Antebi, Joseph
2006-06-01
Many antennas, such as the 100-m Green Bank Telescope, use a wheel-on-track systems in which the track segments consist of wear plates mounted on base plates. The wear plates are typically 2 to 3 inches thick and are case hardened or through hardened. The base plates are usually 3 to 4 times thicker than the wear plates and are not hardened. The wear plates are typically connected to the base plates using bolts. The base plates are supported on grout and anchored to the underlying concrete foundation. For some antennas, slip has been observed between the wear plate and base plate, and between the base plate and the grout, with the migration in the wheel rolling direction. In addition, there has been wear at the wear plate/base plate interface. This paper is an update on the evaluation of GBT track retrofit. The paper describes the use of three-dimensional non-linear finite element analyses to understand and evaluate the behavior of (1) the existing GBT wheel-on-track system with mitered joints, and (2) the various proposed modifications. The modifications include welding of the base plate joints, staggering of the wear plate joints from the base plate joints, changing thickness of the wear plate, and increasing bolt diameter and length. Parameters included in the evaluation were contact pressure, relative slip, wear at the wear plate/base plate interface, and bolt shears and moments.
Wear-Induced Changes in FSW Tool Pin Profile: Effect of Process Parameters
NASA Astrophysics Data System (ADS)
Sahlot, Pankaj; Jha, Kaushal; Dey, G. K.; Arora, Amit
2018-06-01
Friction stir welding (FSW) of high melting point metallic (HMPM) materials has limited application due to tool wear and relatively short tool life. Tool wear changes the profile of the tool pin and adversely affects weld properties. A quantitative understanding of tool wear and tool pin profile is crucial to develop the process for joining of HMPM materials. Here we present a quantitative wear study of H13 steel tool pin profile for FSW of CuCrZr alloy. The tool pin profile is analyzed at multiple traverse distances for welding with various tool rotational and traverse speeds. The results indicate that measured wear depth is small near the pin root and significantly increases towards the tip. Near the pin tip, wear depth increases with increase in tool rotational speed. However, change in wear depth near the pin root is minimal. Wear depth also increases with decrease in tool traverse speeds. Tool pin wear from the bottom results in pin length reduction, which is greater for higher tool rotational speeds, and longer traverse distances. The pin profile changes due to wear and result in root defect for long traverse distance. This quantitative understanding of tool wear would be helpful to estimate tool wear, optimize process parameters, and tool pin shape during FSW of HMPM materials.
Toward Zero Micro/Macro-Scale Wear Using Periodic Nano-Layered Coatings.
Penkov, Oleksiy V; Devizenko, Alexander Yu; Khadem, Mahdi; Zubarev, Evgeniy N; Kondratenko, Valeriy V; Kim, Dae-Eun
2015-08-19
Wear is an important phenomenon that affects the efficiency and life of all moving machines. In this regard, extensive efforts have been devoted to achieve the lowest possible wear in sliding systems. With the advent of novel materials in recent years, technology is moving toward realization of zero wear. Here, we report on the development of new functional coatings comprising periodically stacked nanolayers of amorphous carbon and cobalt that are extremely wear resistant at the micro and macro scale. Because of their unique structure, these coatings simultaneously provide high elasticity and ultrahigh shear strength. As a result, almost zero wear was observed even after one million sliding cycles without any lubrication. The wear rate was reduced by 8-10-fold compared with the best previously reported data on extremely low wear materials.
Molecular dynamics simulation investigations of atomic-scale wear
NASA Astrophysics Data System (ADS)
Shao, Yuchong; Falk, Michael
2013-03-01
Frictional running-in and material transfer in wear take place at the micro- and nano-scale but the fundamental physics remain poorly understood. Here we intend to investigate wear and running-in phenomena in silicon based materials, which are widely utilized in micro/nano electromechanical systems(MEMS/NEMS). We use an atomic force microscopy (AFM) model composed of a crystalline silicon tip and substrate coated with native oxide layers. Molecular dynamics simulation has been performed over a range of temperatures, external loads and slip rates. Results show that adhesive wear takes place across the interface in an atom-by-atom fashion which remodels the tip leading to a final steady state. We quantify the rate of material transfer as a function of the coverage of non-bridging oxygen (NBO) atoms, which has a pronounced change of the system's tribological and wear behaviors. A constitutive rate and state model is proposed to predict the evolution of frictional strength and wear. This work is supported by the National Science Foundation under Award No. 0926111.
Kyomoto, Masayuki; Moro, Toru; Takatori, Yoshio; Tanaka, Sakae; Ishihara, Kazuhiko
2015-03-01
Modifying the surface and substrate of a crosslinked polyethylene (CLPE) liner may be beneficial for high wear resistance as well as high oxidative stability and excellent mechanical properties, which would be useful in contributing to the long-term performance of orthopaedic bearings. A grafted poly(2-methacryloyloxyethyl phosphorylcholine) (PMPC) layer on a vitamin E-blended crosslinked PE (HD-CLPE[VE]) surface may provide hydrophilicity and lubricity without compromising the oxidative stability or mechanical properties. (1) Will the modifications (PMPC grafting and vitamin E blending) affect the lubrication characteristics of the CLPE surface? (2) Will the modifications affect wear resistance? (3) Will the modifications affect fatigue resistance? We investigated the effects of surface and substrate modifications (PMPC grafting and vitamin E blending) on the wear and fatigue fracture of thin CLPE samples. For each of the untreated and PMPC-grafted CLPE surfaces with and without vitamin E blended (four groups), wettability and lubricity surface analyses were conducted as well as multidirectional wear and impact-to-wear tests using a pin-on-disk testing machine. The water wettability and lubricity (CLPE [mean ± 95% confidence interval]: 23.2° ± 1.8°, 0.005 ± 0.001; HD-CLPE[VE]: 26.0° ± 2.3°, 0.009 ± 0.003) of the PMPC-grafted surfaces were greater (p < 0.001) than that (CLPE: 90.3° ± 1.2°, 0.067 ± 0.015; HD-CLPE[VE]: 90.8° ± 2.0°, 0.063 ± 0.008) of the untreated surface regardless of vitamin E additives. It was observed that the PMPC grafting (CLPE: 0.23 ± 0.06 mg; HD-CLPE[VE]: 0.05 ± 0.10 mg) was associated with reduced gravimetric wear (CLPE: 0.53 ± 0.08 mg, p = 0.004 HD-CLPE[VE]: 0.23 ± 0.07 mg, p = 0.038) in the multidirectional wear test. The PMPC-grafted surface characteristics did not appear to affect the impact fatigue resistance regardless of vitamin E blending. PMPC grafting improved the surface hydrophilicity and lubricity, and it
In-silico wear prediction for knee replacements--methodology and corroboration.
Strickland, M A; Taylor, M
2009-07-22
The capability to predict in-vivo wear of knee replacements is a valuable pre-clinical analysis tool for implant designers. Traditionally, time-consuming experimental tests provided the principal means of investigating wear. Today, computational models offer an alternative. However, the validity of these models has not been demonstrated across a range of designs and test conditions, and several different formulas are in contention for estimating wear rates, limiting confidence in the predictive power of these in-silico models. This study collates and retrospectively simulates a wide range of experimental wear tests using fast rigid-body computational models with extant wear prediction algorithms, to assess the performance of current in-silico wear prediction tools. The number of tests corroborated gives a broader, more general assessment of the performance of these wear-prediction tools, and provides better estimates of the wear 'constants' used in computational models. High-speed rigid-body modelling allows a range of alternative algorithms to be evaluated. Whilst most cross-shear (CS)-based models perform comparably, the 'A/A+B' wear model appears to offer the best predictive power amongst existing wear algorithms. However, the range and variability of experimental data leaves considerable uncertainty in the results. More experimental data with reduced variability and more detailed reporting of studies will be necessary to corroborate these models with greater confidence. With simulation times reduced to only a few minutes, these models are ideally suited to large-volume 'design of experiment' or probabilistic studies (which are essential if pre-clinical assessment tools are to begin addressing the degree of variation observed clinically and in explanted components).
USDA-ARS?s Scientific Manuscript database
Reactions of 2,5-bis(benzylthio)-1,3,4-thiadiazole (Compound 1) with a common organometallic rhenium starting material [NEt4]2[fac-[Re(I)Br3(CO)3] yielded two distinct types of complexes. Both complexes coordinate only through the nitrogen of the thiadiazole ring. Reaction of Compound 1 with the rhe...
Prediction Of Abrasive And Diffusive Tool Wear Mechanisms In Machining
NASA Astrophysics Data System (ADS)
Rizzuti, S.; Umbrello, D.
2011-01-01
Tool wear prediction is regarded as very important task in order to maximize tool performance, minimize cutting costs and improve the quality of workpiece in cutting. In this research work, an experimental campaign was carried out at the varying of cutting conditions with the aim to measure both crater and flank tool wear, during machining of an AISI 1045 with an uncoated carbide tool P40. Parallel a FEM-based analysis was developed in order to study the tool wear mechanisms, taking also into account the influence of the cutting conditions and the temperature reached on the tool surfaces. The results show that, when the temperature of the tool rake surface is lower than the activation temperature of the diffusive phenomenon, the wear rate can be estimated applying an abrasive model. In contrast, in the tool area where the temperature is higher than the diffusive activation temperature, the wear rate can be evaluated applying a diffusive model. Finally, for a temperature ranges within the above cited values an adopted abrasive-diffusive wear model furnished the possibility to correctly evaluate the tool wear phenomena.
NASA Astrophysics Data System (ADS)
Kuttolamadom, Mathew Abraham
The objective of this research work is to create a comprehensive microstructural wear mechanism-based predictive model of tool wear in the tungsten carbide / Ti-6Al-4V machining tribosystem, and to develop a new topology characterization method for worn cutting tools in order to validate the model predictions. This is accomplished by blending first principle wear mechanism models using a weighting scheme derived from scanning electron microscopy (SEM) imaging and energy dispersive x-ray spectroscopy (EDS) analysis of tools worn under different operational conditions. In addition, the topology of worn tools is characterized through scanning by white light interferometry (WLI), and then application of an algorithm to stitch and solidify data sets to calculate the volume of the tool worn away. The methodology was to first combine and weight dominant microstructural wear mechanism models, to be able to effectively predict the tool volume worn away. Then, by developing a new metrology method for accurately quantifying the bulk-3D wear, the model-predicted wear was validated against worn tool volumes obtained from corresponding machining experiments. On analyzing worn crater faces using SEM/EDS, adhesion was found dominant at lower surface speeds, while dissolution wear dominated with increasing speeds -- this is in conformance with the lower relative surface speed requirement for micro welds to form and rupture, essentially defining the mechanical load limit of the tool material. It also conforms to the known dominance of high temperature-controlled wear mechanisms with increasing surface speed, which is known to exponentially increase temperatures especially when machining Ti-6Al-4V due to its low thermal conductivity. Thus, straight tungsten carbide wear when machining Ti-6Al-4V is mechanically-driven at low surface speeds and thermally-driven at high surface speeds. Further, at high surface speeds, craters were formed due to carbon diffusing to the tool surface and
Friction and wear life properties of polyimide thin films
NASA Technical Reports Server (NTRS)
Fusaro, R. L.
1972-01-01
A transition in the friction coefficient and wear life properties of Pyralin polyimide (PI) thin films was found to exist at a temperature between 25 deg and 100 deg C. Above this transition, PI thin films gave long wear lives and low friction coefficients. The presence of H2O in air improved the friction and wear life properties at 25 deg C; but at 100 deg C, H2O had a detrimental effect. At 100 deg C and above, a dry argon atmosphere gave lower friction coefficients and longer wear lives than did a dry air atmosphere.
Impact of Advertising on Tampon Wear-time Practices.
Woeller, Kara E; Miller, Kenneth W; Robertson-Smith, Amy L; Bohman, Lisa C
2015-01-01
(1) To determine whether advertising nighttime tampon use for up to eight hours was understood to be consistent with label recommendations and (2) to determine whether television and print advertising with this message affected tampon wear times in adults and teens. (1) A comprehension study (online advertising and follow-up questionnaire) among women aged 14-49 years (300 per group) who viewed either the test or a control advertising message; (2) Diary-based surveys of tampon wear times performed prior to (n = 292 adults, 18-49 years, 74 teens, 12-17 years) and after (n = 287 adults, 104 teens) the launch of national advertising. Significantly more test message viewers than controls stated tampons should be worn less than or equal to eight hours (93.6% vs. 88.6%, respectively, P = 0.049). A directionally higher percentage of test message viewers said they would use a pad if sleeping longer than eight hours (52% vs. 42% of controls). Among the women who used tampons longer than eight hours when sleeping, 52% reported they would wake up and change compared with 45% of controls. No significant difference between baseline and follow-up diary surveys was found among teens or adults in various measures of tampon wear time (mean wear times; usage intervals from less than two hours to more than 10 hours; percentage of tampons used for more than or equal to eight hours; frequency of wearing at least one tampon more than eight hours). Advertising nighttime tampon wear for up to eight hours effectively communicated label recommendations but did not alter tampon wear times. The informational intervention had limited impact on established habits.
NASA Technical Reports Server (NTRS)
Swanson, Theodore
2008-01-01
The focus of this chapter is on the long term wear and tear, or aging, of the mechanical subsystem of a spacecraft. The mechanical subsystem is herein considered to be the primary support structure (as in a skeleton or exoskeleton) upon which all other spacecraft systems rest, and the associated mechanisms. Mechanisms are devices which have some component that moves at least once, in response to some type of passive or active control system. For the structure, aging may proceed as a gradual degradation of mechanical properties and/or function, possibly leading to complete structural failure over an extended period of time. However, over the 50 years of the Space Age such failures appear to be unusual. In contrast, failures for mechanisms are much more frequent and may have a very serious effect on mission performance. Just as on Earth, all moving devices are subject to normal (and possibly accelerated) degradation from mechanical wear due to loss or breakdown of lubricant, misalignment, temperature cycling effects, improper design/selection of materials, fatigue, and a variety of other effects. In space, such environmental factors as severe temperature swings (possibly 100's of degrees C while going in and out of direct solar exposure), hard vacuum, micrometeoroids, wear from operation in a dusty or contaminated environment, and materials degradation from radiation can be much worse. In addition, there are some ground handling issues such as humidity, long term storage, and ground transport which may be of concern. This chapter addresses the elements of the mechanical subsystem subject to wear, and identifies possible causes. The potential impact of such degradation is addressed, albeit with the recognition that the impact of such wear often depends on when it occurs and on what specific components. Most structural elements of the mechanical system typically are conservatively designed (often to a safety factor of greater than approximately 1.25 on yield for
Consideration of wear rates at high velocity
NASA Astrophysics Data System (ADS)
Hale, Chad S.
The development of the research presented here is one in which high velocity relative sliding motion between two bodies in contact has been considered. Overall, the wear environment is truly three-dimensional. The attempt to characterize three-dimensional wear was not economically feasible because it must be analyzed at the micro-mechanical level to get results. Thus, an engineering approximation was carried out. This approximation was based on a metallographic study identifying the need to include viscoplasticity constitutive material models, coefficient of friction, relationships between the normal load and velocity, and the need to understand wave propagation. A sled test run at the Holloman High Speed Test Track (HHSTT) was considered for the determination of high velocity wear rates. In order to adequately characterize high velocity wear, it was necessary to formulate a numerical model that contained all of the physical events present. The experimental results of a VascoMax 300 maraging steel slipper sliding on an AISI 1080 steel rail during a January 2008 sled test mission were analyzed. During this rocket sled test, the slipper traveled 5,816 meters in 8.14 seconds and reached a maximum velocity of 1,530 m/s. This type of environment was never considered previously in terms of wear evaluation. Each of the features of the metallography were obtained through micro-mechanical experimental techniques. The byproduct of this analysis is that it is now possible to formulate a model that contains viscoplasticity, asperity collisions, temperature and frictional features. Based on the observations of the metallographic analysis, these necessary features have been included in the numerical model, which makes use of a time-dynamic program which follows the movement of a slipper during its experimental test run. The resulting velocity and pressure functions of time have been implemented in the explicit finite element code, ABAQUS. Two-dimensional, plane strain models
Wear Characteristics and Volume Loss of CAD/CAM Ceramic Materials.
Zurek, Alec D; Alfaro, Maria F; Wee, Alvin G; Yuan, Judy Chia-Chun; Barao, Valentim A; Mathew, Mathew T; Sukotjo, Cortino
2018-03-06
In the field of prosthodontics, patients often require complex and extensive restorative care. This can involve the use of dental restorations to restore teeth on both the maxillary and mandibular arch. Current literature has evaluated the wear properties of different dental ceramics against enamel, but studies regarding dental ceramics opposing one another are limited. The purpose of this study was to assess the wear potential and wear behavior of CAD/CAM zirconia (ZR) and lithium disilicate (LD) materials against a similar ceramic material, and how the surface finish of these dental ceramics might affect patterns of wear. Using a sphere-on-plate tribometer system, different surface finishes (glazed-G and glazed then polished-GP) of ZR and LD were evaluated following wear simulation. Artificial saliva of physiologic pH was used as a lubricant during wear simulation at 37°C. The coefficient of friction (COF) was calculated during the wear simulation. After wear simulation was complete, volume loss, surface roughness, and surface characterization of the specimens were analyzed using white-light interferometry and scanning electron microscopy (SEM). Statistical significance between materials and surface finish was established with two-way ANOVA and Bonferroni post hoc test (α = 0.05). Based on the 2-way ANOVA, material (p = 0.002) significantly affected the COF. LD showed a higher COF (p = 0.002) than ZR. Material (p < 0.001) and surface finish (p = 0.004) significantly affected the surface roughness inside the scar. ZR had significantly lower surface roughness compared to LD (p < 0.001). For outside scar, surface finish (p < 0.001) significantly affected the surface roughness. Polished specimens showed significantly higher roughness compared to glazed specimens for both inside (p = 0.004) and outside scar (p < 0.001). For volume loss, material (p < 0.001) and the interaction between material and surface finish (p < 0.001) were statistically significant. LD had
A mechanistic understanding of the wear coefficient: From single to multiple asperities contact
NASA Astrophysics Data System (ADS)
Frérot, Lucas; Aghababaei, Ramin; Molinari, Jean-François
2018-05-01
Sliding contact between solids leads to material detaching from their surfaces in the form of debris particles, a process known as wear. According to the well-known Archard wear model, the wear volume (i.e. the volume of detached particles) is proportional to the load and the sliding distance, while being inversely proportional to the hardness. The influence of other parameters are empirically merged into a factor, referred to as wear coefficient, which does not stem from any theoretical development, thus limiting the predictive capacity of the model. Based on a recent understanding of a critical length-scale controlling wear particle formation, we present two novel derivations of the wear coefficient: one based on Archard's interpretation of the wear coefficient as the probability of wear particle detachment and one that follows naturally from the up-scaling of asperity-level physics into a generic multi-asperity wear model. As a result, the variation of wear rate and wear coefficient are discussed in terms of the properties of the interface, surface roughness parameters and applied load for various rough contact situations. Both new wear interpretations are evaluated analytically and numerically, and recover some key features of wear observed in experiments. This work shines new light on the understanding of wear, potentially opening a pathway for calculating the wear coefficient from first principles.
Skotnitsky, Cheryl C; Naduvilath, Thomas J; Sweeney, Deborah F; Sankaridurg, Padmaja R
2006-01-01
The purpose of this study was to confirm that two distinct clinical presentations of contact lens-induced papillary conjunctivitis (CLPC), local and general, occur in hydrogel lens wear. Retrospective analyses of 124 CLPC events were identified. The classification of CLPC was based on location and extent of papillae. CLPC was classified as local if papillae were present in one to two areas of the tarsal conjunctiva and general if papillae occurred in three or more areas. The CLPC events were compared with an asymptomatic control group in prospective clinical trials conducted from 1993 until 2003 at two clinical sites, Australia and India. Two hundred sixteen subjects from Australia and 914 subjects from India wore either high Dk silicone hydrogel or low Dk hydrogel lenses on a 6-night (6N) or 30-night extended-wear (EW) schedule. The physiological responses of the ocular surface, including tarsal conjunctiva redness and roughness, number of papillae present, lens fit and performance, and subjective patient symptoms, were measured during each visit at each site. These variables listed were compared between local CLPC groups and asymptomatic controls and general CLPC groups and asymptomatic controls. Two types of CLPC in hydrogel lens wearers have been confirmed. Of the 124 CLPC events, there were 61 local and 63 general events. Local and general CLPC cases reported significantly greater frequency of symptoms compared with the asymptomatic controls, in particular itching, lens awareness, secretion, and blurred vision (p < 0.1). The classification of CLPC into two types, local and general, in hydrogel lens wear was confirmed based on presentations at both sites. This distribution of papillae between local and general CLPC may indicate separate etiologies involved in the pathogenesis of the condition.
22 CFR 1203.735-212 - Wearing of uniforms.
Code of Federal Regulations, 2010 CFR
2010-04-01
... RESPONSIBILITIES AND CONDUCT Ethical and Other Conduct and Responsibilities of Employees § 1203.735-212 Wearing of....2b prohibits the purchase from Agency funds of uniforms or any item of personal wearing apparel other...
Investigation of wear resistance of polyurethanes in abrasive soil mass
NASA Astrophysics Data System (ADS)
Napiórkowski, Jerzy; Ligier, Krzysztof
2018-04-01
This paper presents a comparative study of polyurethane wear in different abrasive soil masses. Two types of polyurethanes of various chemical compositions and untreated 38GSA steel were tested, the latter being used as a reference standard. The study was conducted in natural soil mass at a "rotating bowl" stand. Relative wear resistance was determined from measurements of mass wear for the materials under study. The condition of the surface of the materials under wear test was analysed.
The microstructural dependence of wear resistance in austenite containing plate steels
NASA Astrophysics Data System (ADS)
Wolfram, Preston Charles
The purpose of this project was to examine the microstructural dependence of wear resistance of various plate steels, with interests in exploring the influence of retained austenite (RA). Materials resistant to abrasive wear are desirable in the industrial areas of agriculture, earth moving, excavation, mining, mineral processing, and transportation. Abrasive wear contributes to significant financial cost associated with wear to the industry. The motivation for the current study was to determine whether it would be beneficial from a wear resistance perspective to produce plate steels with increased amounts of retained austenite. This thesis investigates this motivation through a material matrix containing AR400F, Abrasive (0.21 wt pct C, 1.26 wt pct Mn, 0.21 wt pct Si, 0.15 wt pct Ni, 0.18 wt pct Mo), Armor (0.46 wt pct C, 0.54 wt pct Mn, 0.36 wt pct Si, 1.74 wt pct Ni, 0.31 wt pct Mo), 9260, 301SS, Hadfield, and SAE 4325 steels. The Abrasive, Armor and 9260 steels were heat treated using different methods such as quench and temper, isothermal bainitic hold, and quench and partitioning (Q&P). These heat treatments yielded various microstructures and the test matrix allowed for investigation of steels with similar hardness and varying levels of RA. The wear test methods used consisted of dry sand rubber wheel (DSRW), impeller-tumbler impact-abrasion (impeller), and Bond abrasion wear testing. DSRW and impeller wear resistance was found to increase with hardness and retained austenite levels at certain hardness levels. Some Q&P samples exhibited similar or less wear than the Hadfield steels in DSRW and impeller tests. Scanning electron microscopy investigation of wear surfaces revealed different wear mechanisms for the different wear test methods ranging from micro-plowing, to micro-cutting and to fragmentation.
Wear resistance of hydrophobic surfaces
NASA Astrophysics Data System (ADS)
Martinez, MA; Abenojar, J.; Pantoja, M.; López de Armentia, S.
2017-05-01
Nature has been an inspiration source to develop artificial hydrophobic surfaces. During the latest years the development of hydrophobic surfaces has been widely researched due to their numerous ranges of industrial applications. Industrially the use of hydrophobic surfaces is being highly demanded. This is why many companies develop hydrophobic products to repel water, in order to be used as coatings. Moreover, these coating should have the appropriated mechanical properties and wear resistance. In this work wear study of a hydrophobic coating on glass is carried out. Hydrophobic product used was Sika Crystal Dry by Sika S.A.U. (Alcobendas, Spain). This product is currently used on car windshield. To calculate wear resistance, pin-on-disk tests were carried out in dry and water conditions. The test parameters were rate, load and sliding distance, which were fixed to 60 rpm, 5 N and 1000 m respectively. A chamois was used as pin. It allows to simulate a real use. The friction coefficient and loss weight were compared to determinate coating resistance
In vivo measurements of tooth wear over 12 months.
Rodriguez, J M; Austin, R S; Bartlett, D W
2012-01-01
The aim of this study was to measure the progression of tooth wear in a cohort of 63 patients, 43 males and 20 females with a mean age of 39.1 years. Recruitment followed referral from general practice to Guy's Hospital for advice/management of tooth wear. Addition silicone impressions were taken at 6-month intervals for a total of 12 months; impressions were subsequently poured in type IV gypsum. Casts were scanned using a non-contacting laser profilometer and then superimposed using Geomagic® Qualify 11. Wear was measured in μm by tooth per time interval. A questionnaire highlighting dietary, parafunctional and gastric risk factors was obtained from each participant. Clustered multiple regression analysis was used to determine the relationship between tooth wear progression and risk factors. Maximum follow-up times were 6 months for 63 participants and 12 months for 30 participants. The measurement error was 15 μm. At the tooth level, 72.2% of 1,078 teeth wore <15 μm over a 6-month period. At the subject level, 77.7% of 63 participants showed median wear <15 μm over a 6-month period. There was a statistical trend towards tooth wear progression being associated with gastric risk factors (p < 0.05). The lower molars and the upper anterior teeth were the most commonly affected teeth; the lower molars and the upper central incisors were the most severely affected teeth. Tooth wear progression was slow in this cohort, suggesting that tooth wear may be cyclical and inactive in the majority of participants. Copyright © 2011 S. Karger AG, Basel.
Validation of accelerometer wear and nonwear time classification algorithm.
Choi, Leena; Liu, Zhouwen; Matthews, Charles E; Buchowski, Maciej S
2011-02-01
the use of movement monitors (accelerometers) for measuring physical activity (PA) in intervention and population-based studies is becoming a standard methodology for the objective measurement of sedentary and active behaviors and for the validation of subjective PA self-reports. A vital step in PA measurement is the classification of daily time into accelerometer wear and nonwear intervals using its recordings (counts) and an accelerometer-specific algorithm. the purpose of this study was to validate and improve a commonly used algorithm for classifying accelerometer wear and nonwear time intervals using objective movement data obtained in the whole-room indirect calorimeter. we conducted a validation study of a wear or nonwear automatic algorithm using data obtained from 49 adults and 76 youth wearing accelerometers during a strictly monitored 24-h stay in a room calorimeter. The accelerometer wear and nonwear time classified by the algorithm was compared with actual wearing time. Potential improvements to the algorithm were examined using the minimum classification error as an optimization target. the recommended elements in the new algorithm are as follows: 1) zero-count threshold during a nonwear time interval, 2) 90-min time window for consecutive zero or nonzero counts, and 3) allowance of 2-min interval of nonzero counts with the upstream or downstream 30-min consecutive zero-count window for detection of artifactual movements. Compared with the true wearing status, improvements to the algorithm decreased nonwear time misclassification during the waking and the 24-h periods (all P values < 0.001). the accelerometer wear or nonwear time algorithm improvements may lead to more accurate estimation of time spent in sedentary and active behaviors.
Characteristics of highly cross-linked polyethylene wear debris in vivo
Baxter, Ryan M.; MacDonald, Daniel W.; Kurtz, Steven M.; Steinbeck, Marla J.
2014-01-01
Despite the widespread implementation of highly cross-linked polyethylene (HXLPE) liners to reduce the clinical incidence of osteolysis, it is not known if the improved wear resistance will outweigh the inflammatory potential of HXLPE wear debris generated in vivo. Thus, we asked: What are the differences in size, shape, number, and biological activity of polyethylene wear particles obtained from primary total hip arthroplasty revision surgery of conventional polyethylene (CPE) versus remelted or annealed HXLPE liners? Pseudocapsular tissue samples were collected from revision surgery of CPE and HXLPE (annealed and remelted) liners, and digested using nitric acid. The isolated polyethylene wear particles were evaluated using scanning electron microscopy. Tissues from both HXLPE cohorts contained an increased percentage of submicron particles compared to the CPE cohort. However, the total number of particles was lower for both HXLPE cohorts, as a result there was no significant difference in the volume fraction distribution and specific biological activity (SBA; the relative biological activity per unit volume) between cohorts. In contrast, based on the decreased size and number of HXLPE wear debris there was a significant decrease in total particle volume (mm3/g of tissue). Accordingly, when the SBA was normalized by total particle volume (mm3/gm tissue) or by component wear volume rate (mm3/year), functional biological activity of the HXLPE wear debris was significantly decreased compared to the CPE cohort. Indications for this study are that the osteolytic potential of wear debris generated by HXLPE liners in vivo is significantly reduced by improvements in polyethylene wear resistance. PMID:23436587
Occlusal tooth wear in Chinese adults with shortened dental arches.
Zhang, Q; Witter, D J; Bronkhorst, E M; Bartlett, D W; Creugers, N H J
2014-02-01
To assess associations between occlusal tooth wear and shortened dental arches (SDA) in Chinese 40 years and older subjects. From a sample of 1462 urban and rural adults, those presenting with SDA (n = 150) were compared with a control group of 65 randomly selected subjects with complete dentitions (CDA). Occlusal wear was assessed using a modified Smith and Knight index - the occlusal tooth wear index (OWTI) - and analysed using multivariate (logistic) regression. There was no significant effect from SDA on severe occlusal wear (OTWI score 3 or 4: OR = 2.016; 95% CI = 0.960-4.231; P = 0.064). Higher age was associated with severe occlusal wear (P values ≤0.007) and with higher mean OTWI scores; urban had less often severe occlusal wear than rural residents (OR = 0.519; P = 0.008). Higher mean OTWI scores were associated with rural residents, except for anterior teeth. Females had lower mean OTWI score for anterior teeth (effect = -0.153; P = 0.030). Premolars in SDA had higher mean OTWI scores compared with those in CDA (effect = +0.213; P = 0.006). In SDA, more posterior occluding pairs (POPs) were associated with lower mean OTWI sores for anterior teeth (effect: -0.158; P = 0.008) and higher scores for molars (effect: +0.249, P = 0.003). Subjects with SDA or CDA presented comparable occlusal wear, but premolars in SDA tend to have higher probability for having occlusal wear. Fewer numbers of POPs were associated with more wear in anterior teeth. © 2013 John Wiley & Sons Ltd.
Extended wearing trial of Trifield lens device for 'tunnel vision'.
Woods, Russell L; Giorgi, Robert G; Berson, Eliot L; Peli, Eli
2010-05-01
Severe visual field constriction (tunnel vision) impairs the ability to navigate and walk safely. We evaluated Trifield glasses as a mobility rehabilitation device for tunnel vision in an extended wearing trial. Twelve patients with tunnel vision (5-22 degrees wide) due to retinitis pigmentosa or choroideremia participated in the 5-visit wearing trial. To expand the horizontal visual field, one spectacle lens was fitted with two apex-to-apex prisms that vertically bisected the pupil on primary gaze. This provides visual field expansion at the expense of visual confusion (two objects with the same visual direction). Patients were asked to wear these spectacles as much as possible for the duration of the wearing trial (median 8, range 6-60 weeks). Clinical success (continued wear, indicating perceived overall benefit), visual field expansion, perceived direction and perceived visual ability were measured. Of 12 patients, nine chose to continue wearing the Trifield glasses at the end of the wearing trial. Of those nine patients, at long-term follow-up (35-78 weeks), three reported still wearing the Trifield glasses. Visual field expansion (median 18, range 9-38 degrees) was demonstrated for all patients. No patient demonstrated adaptation to the change in visual direction produced by the Trifield glasses (prisms). For reported difficulty with obstacles, some differences between successful and non-successful wearers were found. Trifield glasses provided reported benefits in obstacle avoidance to 7 of the 12 patients completing the wearing trial. Crowded environments were particularly difficult for most wearers. Possible reasons for long-term discontinuation and lack of adaptation to perceived direction are discussed.
Wu, Bo-Han; Huang, Min-Jie; Lai, Cheng-Chang; Cheng, Chien-Hong; Chen, I-Chia
2018-04-16
We developed a new method by enclosing the complex tris(2-phenylpyridinato-N,C2')Iridium(III), Ir(ppy) 3 with surfactant cetyltrimethylammonium bromide (CATB), coated with a thin layer of silica then bonded to the surface of silver nanoparticle. These samples were used to acquire surface-enhanced Raman scattering (SERS) spectra. The thickness of silica layer was controlled to have efficient phosphorescence quenching and Raman enhancement by metal nanoparticle. The SERS spectra of fac- and mer-Ir(ppy) 3 , recorded at 633 nm excitation, display distinct ring breathing mode features because the total symmetric vibrational bands were enhanced. This provides a convenient means to differentiate these isomers with great sensitivity and to study their isomerization process. A direct conversion reaction of mer- to fac- isomerization is identified with time constant 3.1 min when mer was irradiated with Xe light. Via thermal activation, under moderate conditions (pH 5.5 and 343 K), we observed an intermediate particularly with new bands 320/662 cm -1 after heating for 17.5 h, and then those bands disappeared to form fac-Ir(ppy) 3 . On the basis of DFT calculations, the intermediate is proposed to contain octahedral N-N Ir(ppy) 3 -HO-silica structure; band at 320 cm -1 is assigned to iridium oxygen stretching mode ν Ir-O of this intermediate. Under acidic conditions, pH 1-2 catalyzed by silanol in silica, byproduct with band at 353 cm -1 was observed. According to the SERS bands and the calculation, this byproduct is assigned to be iridium(III) siloxide, and the new band is assigned to ν Ir-O .
Fac-Re(bpy)(CO){sub 3}(COOMe): A model metallocarboxylate complex of rhenium with a bipyridyl ligand
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gibson, D.H.; Sleadd, B.A.; Vij, A.
1999-05-01
The title compound fac-(2,2{prime}-bipyridyl)(carbomethoxy)rhenium tricarbonyl, crystallizes in the monoclinic system, space group P2{sub 1}/c with the following crystal data: a = 8.37551(1), b = 6.6934(1), c = 26.2098(1) {angstrom}, V({angstrom}{sup 3}) = 1,535.93(3), Z = 4, and {beta} = 90.0971(2). The metal environment is slightly distorted octahedral with a chelating bipyridyl ligand and a facial arrangement of the carbon monoxide ligands.
Tooth wear prevention: a quantitative and qualitative in vitro study.
Kaidonis, J A; Gratiaen, J; Bhatia, N; Richards, L C; Townsend, G C
2003-03-01
Management of tooth wear from grinding presents a significant clinical challenge. Acrylic nightguards are often used to protect the teeth, but many patients still grind with these appliances. This study aimed to test the effectiveness of three lubricants in reducing enamel wear by using an electro-mechanical machine under controlled conditions, with a view to undertaking a subsequent longitudinal clinical study. Sectioned tooth specimens were worn against each other under different loads and with the addition of three different lubricants: calcium fluoride (CaF) powder, olive-oil, and a combination of calcium fluoride with olive-oil in the form of a slurry. Wear rates of enamel only were quantified by weighing the specimens, and resin replicas of the worn tooth surfaces were made for examination under a scanning electron microscope. All three lubricants reduced the amount of enamel wear significantly compared with wearing specimens without adding lubricants. Wear rate was influenced by the type of lubricant and the load applied. Wear rates were significantly less for olive-oil and the olive-oil/CaF slurry compared with CaF alone. The microwear detail differed between the three lubricants. This study has shown that enamel wear can be reduced using dry or wet lubricants between opposing teeth that are worn under controlled conditions. Further research is required to clarify their possible clinical applications.
Wear characteristics of bonded solid film lubricant under high load condition
NASA Technical Reports Server (NTRS)
Hiraoka, Naofumi; Sasaki, Akira; Kawashima, Noritsugu; Honda, Toshio
1991-01-01
Wear properties of phenolic resin bonded molybdenum disulfide film lubricant were studied. In-vacuo journal bearing tests were performed to evaluate the wear-life of this film lubricant. The wear-life depends on substrate materials and on sliding velocity. Pretreated substrate surfaces were examined to reveal the reasons for these results. Additionally, investigations on film wear mechanisms were made.
Alternate paddle configuration for improved wear resistance in the saltstone mixer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reigel, M.; Fowley, M.
The Saltstone Production Facility has a 10-inch Readco-Kurimoto continuous mixer that mixes the premix dry feeds and low-level waste salt solution to make fresh (uncured) saltstone. Inspection of the mixer in January 2013 showed significant wear on the third, fourth and fifth paddle pairs after the conveying augers. A 2-inch Readco-Kurimoto continuous mixer was used to test alternate paddle configurations for use in the 10-inch mixer to decrease the wear rate on the paddles. Two wear tests were conducted to investigate a method of reducing wear on the mixer paddles. The first test (wear test 2a) had a paddle configurationmore » similar to the currently installed 10-inch mixer in the SPF. This test established baseline wear. The second test (wear test 2b) had a reconfigured paddle arrangement that replaced the flat paddles with helical paddles for paddle pairs 2 - 6 and aligned paddle pair 1 with the augers. The intent of the reconfiguration was to more effectively convey the partially wetted dry feeds through the transition region and into the liquid feed where paddle wear is reduced due to dry feeds and salt solution being mixed at the intended water to premix ratio. The design of the helical paddles provides conveyance through the transition region to the liquid feed inlet. The alignment with the auger is aimed to provide a smoother transition (minimizing the discontinuity between the auger and paddle pair 1) into the downstream paddles. A soft metal with low wear resistance (6000 series aluminum) was used for the wear testing paddles to determine wear patterns while minimizing run time and maximizing wear rate. For the two paddle configurations tested using the scaled 2-inch Readco-Kurimoto continuous mixer, with the first six paddles after the augers replaced by the wear paddles and the remaining paddles were stainless steel. Since the 10-inch SPF mixer is designed with the liquid inlet centered over paddle pairs 5 and 6, the scaled 2-inch mixer was
Diagnosis and management of dental wear.
Harpenau, Lisa A; Noble, Warden H; Kao, Richard T
2011-04-01
Dental wear is loss of tooth structure resulting from erosion, attrition, abrasion, and, possibly, abfraction. Clinical/experimental data suggest no single damaging mechanism but rather simultaneous interaction of these destructive processes. The most important interaction is abrasion/attrition potentiated by dental erosion. Awareness of this pathosis is not well-appreciated by the public and dental professionals because the signs may be subtle. This article focuses on the recognition, diagnosis, and management of dental wear.
Wear Analysis of Thermal Spray Coatings on 3D Surfaces
NASA Astrophysics Data System (ADS)
Tillmann, W.; Luo, W.; Selvadurai, U.
2014-01-01
Even though the application of thermal spray coatings on complex geometries gained a greater interest in the last decade, the effect of different geometrical features on the wear behavior is still ill-defined. In this study, the wear resistance of FTC-FeCSiMn coated 3D surfaces was investigated. The wear test was carried out by means of two innovative testing procedures. The first test is a Pin-on-Tubes test where the rotating motion is realized by a lathe chuck. The specimens in the second test were fixed on the table and a robot arm operated the pin. This wear test was applied on specimens with concave or convex surfaces. The residual stresses, which were determined by means of an incremental hole-drilling method, show a dependency on the substrate geometry. The obtained stresses were put in relation to the different radii. After the wear test, a 3D-profilometer determined the wear volume and the sections of the coatings were characterized by a scanning electron microscope. The results indicate that the wear resistance is strongly influenced by the geometry of the substrate.
The role of erosion, abrasion and attrition in tooth wear.
Barbour, Michele E; Rees, Gareth D
2006-01-01
There is increasing clinical awareness of erosion of enamel and dentine by dietary acids and the consequent increased susceptibility to physical wear. Enamel erosion is characterized by acid-mediated surface softening that, if unchecked, will progress to irreversible loss of surface tissue, potentially exposing the underlying dentine. In comparison, dentine erosion is less well understood as the composition and microstructure are more heterogeneous. Factors which affect the erosive potential of a solution include pH, titratable acidity, common ion concentrations, and frequency and method of exposure. Abrasion and attrition are sources of physical wear and are commonly associated with tooth brushing and tooth-to-tooth contact, respectively. A combination of erosion and abrasion or attrition exacerbates wear; however, further research is required to understand the role of fluoride in protecting mineralized tissues from such processes. Abrasive wear may be seen in a wide range of patients, whereas attritive loss is usually seen in individuals with bruxism. Wear processes are implicated in the development of dentine hypersensitivity. Saliva confers the major protective function against wear due to its role in pellicle formation, buffering, acid clearance, and hard tissue remineralization. This review focuses on the physiochemical factors impacting tooth wear.
NASA Astrophysics Data System (ADS)
Bongale, Arunkumar M.; Kumar, Satish; Sachit, T. S.; Jadhav, Priya
2018-03-01
Studies on wear properties of Aluminium based hybrid nano composite materials, processed through powder metallurgy technique, are reported in the present study. Silicon Carbide nano particles and E-glass fibre are reinforced in pure aluminium matrix to fabricate hybrid nano composite material samples. Pin-on-Disc wear testing equipment is used to evaluate dry sliding wear properties of the composite samples. The tests were conducted following the Taguchi’s Design of Experiments method. Signal-to-Noise ratio analysis and Analysis of Variance are carried out on the test data to find out the influence of test parameters on the wear rate. Scanning Electron Microscopic analysis and Energy Dispersive x-ray analysis are conducted on the worn surfaces to find out the wear mechanisms responsible for wear of the composites. Multiple linear regression analysis and Genetic Algorithm techniques are employed for optimization of wear test parameters to yield minimum wear of the composite samples. Finally, a wear model is built by the application of Artificial Neural Networks to predict the wear rate of the composite material, under different testing conditions. The predicted values of wear rate are found to be very close to the experimental values with a deviation in the range of 0.15% to 8.09%.
USDA-ARS?s Scientific Manuscript database
Developing strategies to rapidly incorporate the fac-[MI(CO)3]+ (M = Re, 99mTc) core into biological targeting vectors is a growing realm in radiopharmaceutical development. This work presents the preparation of a novel isothiocyanate-functionalized bifunctional chelate based on 2,2´-dipicolylamine ...
Impact of Advertising on Tampon Wear-time Practices
Woeller, Kara E.; Miller, Kenneth W.; Robertson-Smith, Amy L.; Bohman, Lisa C.
2015-01-01
OBJECTIVES (1) To determine whether advertising nighttime tampon use for up to eight hours was understood to be consistent with label recommendations and (2) to determine whether television and print advertising with this message affected tampon wear times in adults and teens. METHODS (1) A comprehension study (online advertising and follow-up questionnaire) among women aged 14–49 years (300 per group) who viewed either the test or a control advertising message; (2) Diary-based surveys of tampon wear times performed prior to (n = 292 adults, 18–49 years, 74 teens, 12–17 years) and after (n = 287 adults, 104 teens) the launch of national advertising. RESULTS Significantly more test message viewers than controls stated tampons should be worn less than or equal to eight hours (93.6% vs. 88.6%, respectively, P = 0.049). A directionally higher percentage of test message viewers said they would use a pad if sleeping longer than eight hours (52% vs. 42% of controls). Among the women who used tampons longer than eight hours when sleeping, 52% reported they would wake up and change compared with 45% of controls. No significant difference between baseline and follow-up diary surveys was found among teens or adults in various measures of tampon wear time (mean wear times; usage intervals from less than two hours to more than 10 hours; percentage of tampons used for more than or equal to eight hours; frequency of wearing at least one tampon more than eight hours). CONCLUSIONS Advertising nighttime tampon wear for up to eight hours effectively communicated label recommendations but did not alter tampon wear times. The informational intervention had limited impact on established habits. PMID:26688668
2014-01-01
Background The aim of this study was to estimate the prevalence of tooth wear in the aging population of northwest China and to investigate the factors associated with such tooth wear. Methods Cross-sectional analytic clinical and questionnaire study was performed in 704 participants who had a mean age of 46.5 ± 0.2 SD and of which 367(52.13%) were males and 337(47.87%) female. These participants were invited when they attended the hospital which located in northwest China for routine oral examination. Results In the maxilla of the examined patients, the rate of tooth wear varied from 85.51% for molar group, 89.77% for premolar group, 100.0% for canine group to 87.22% for incisor group. In the mandible, the rates were 86.36%, 88.92%, 100.0% and 91.19% for the four groups respectively. Moreover, both the incisor and canine groups of these patients showed median scores of 3, the premolar group showed a median score of 1, and the molar group had a median score of 2. Additionally, multiple factors were considered to contribute to these patterns of tooth wear, especially the habitual consumption of a hard or sour diet (P < 0.05,odds ratio 1.21, 95% confidence intervals 1.04-1.49). Conclusions Tooth wear is a common disease in which the anterior teeth exhibit greater wear than posterior teeth. The data support an association between tooth wear and dietary patterns. PMID:24902953
Three-body wear of resin denture teeth with and without nanofillers.
Stober, Thomas; Henninger, Moritz; Schmitter, Marc; Pritsch, Maria; Rammelsberg, Peter
2010-02-01
The wear behavior of newly developed denture teeth with nanofillers may be different from teeth with other chemical formulations. The purpose of this study was to examine the 3-body wear resistance of 11 different commercially available resin denture teeth. The materials tested were conventional (SR Orthotyp PE, Orthognath) and cross-linked acrylic resin teeth without inorganic fillers (Premium 8, SR Postaris DCL, Trubyte Portrait, Artiplus), composite resin teeth with inorganic fillers (SR Orthosit PE, Vitapan), and composite resin teeth (experimental materials) with inorganic nanofillers (NC Veracia Posterior, e-Ha, Mondial). Human enamel and a ceramic denture tooth (Lumin Vacuum) were used as reference materials. The 3-body wear test was performed in a wear machine developed by the Academic Center for Dentistry Amsterdam (ACTA), with millet suspension acting as an abrasive medium (n=10, test load: 15 N, slip rate: 20%, number of cycles: 100,000). Wear was determined with the aid of a profilometer. Data were analyzed with the Kruskal-Wallis test and Mann-Whitney U test using the closed testing approach (significance level for familywise error rate, alpha=.05). None of the acrylic and composite resin materials tested in this study demonstrated the 3-body wear resistance of ceramic teeth or human enamel. Teeth with inorganic fillers demonstrated significantly lower wear values than conventional or cross-linked acrylic resin teeth without fillers. Composite resin teeth with traditional fillers showed significantly lower wear than composite resin teeth with nanofillers. Denture teeth with and without inorganic fillers differed significantly with regard to the degree of wear generated in the ACTA wear simulator. The incorporation of nanofillers did not improve the wear resistance compared to teeth with traditional fillers.
Comparison of wear between occlusal splint materials and resin composite materials.
Reyes-Sevilla, M; Kuijs, R H; Werner, A; Kleverlaan, C J; Lobbezoo, F
2018-07-01
Tooth wear in bruxing patients often results in a need for treatment with composite restorations. In some cases, bruxing patients receive an occlusal splint as a protective means as well. However, the wear between these opposing materials has not been investigated yet. The aim of this in vitro study was to assess the wear of different splint materials against resin composite materials. A two-body wear test was conducted using the ACTA wear machine. The materials selected for this study were three composites used for direct restorations (Filtek Z250, CLEARFIL AP-X, and Filtek Supreme XT) and four occlusal splints materials, viz. a polyamide resin (ThermoSens) an conventional (hand-processed), milled and printed polymethylmethacrylate (PMMA). As antagonistic materials, stainless steel, Filtek Supreme XT and CLEARFIL AP-X were used. The wear rate of the seven materials was determined after 200 000 cycles, using a profilometry. The rates were analysed using two-way ANOVA and post hoc Tukey's tests. The wear rates were significantly higher for the conventional and milled PMMA materials than for all other materials (P < .001). The wear rates of printed PMMA and the polyamide resin were comparable to composite wear rates. The antagonist materials have minor or no influence on the amount of wear of the various splint materials (P < .001). In conclusion, different splint materials yielded different wear rates for all antagonist materials tested. Keeping in mind that this study is an experimental in vitro study, this finding enables practitioners to choose the splint material necessary according to their patients' needs. © 2018 John Wiley & Sons Ltd.
Degradation of titanium drillpipe from corrosion and wear
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ferg, T.E.; Aldrich, C.S.; Craig, B.D.
1993-06-01
Drilling deeper than 35,000 ft is limited by the extreme hook loads of steel drillpipe and temperature constraints of aluminum drillpipe. Titanium Alloys Ti-6Al-4V and Beta C have been proposed for use in drillpipe for wells deeper than 35,000 ft because of their high strength/weight ratios, superior high-temperature corrosion resistance, and thermal stability. Their suitability in drilling environments, however, has not been evaluated. To determine the corrosion and wear characteristics of two types of titanium-alloy drillpipe under dogleg conditions, a test cell was constructed to test titanium drillpipe joints in contact with API Spec. 5CT Grade P-110 casing in differentmore » drilling muds. Titanium-alloy pipe and Grade P-110 casing wear rates were measured, and tests showed that both titanium-alloy pipes exhibited much greater wear than did steel drillpipe in water-based mud under the same conditions. Test data showed that the total wear rate of Alloys Ti-6Al-4V and Beta C in a drilling environment is a combination of mechanical wear and corrosion.« less
Wear-Resistant, Self-Lubricating Surfaces of Diamond Coatings
NASA Technical Reports Server (NTRS)
Miyoshi, Kazuhisa
1995-01-01
In humid air and dry nitrogen, as-deposited, fine-grain diamond films and polished, coarse-grain diamond films have low steady-state coefficients of friction (less than 0.1) and low wear rates (less than or equal to 10(exp -6) mm(exp 3)/N-m). In an ultrahigh vacuum (10(exp -7) Pa), however, they have high steady-state coefficients of friction (greater than 0.6) and high wear rates (greater than or equal to 10(exp -4) mm(exp 3)/N-m). Therefore, the use of as-deposited, fine-grain and polished, coarse-grain diamond films as wear-resistant, self-lubricating coatings must be limited to normal air or gaseous environments such as dry nitrogen. On the other hand, carbon-ion-implanted, fine-grain diamond films and nitrogen-ion-implanted, coarse-grain diamond films have low steady-state coefficients of friction (less than 0.1) and low wear rates (less than or equal to 10(exp -6) mm(exp 3)/N-m) in all three environments. These films can be effectively used as wear-resistant, self-lubricating coatings in an ultrahigh vacuum as well as in normal air and dry nitrogen.
Evaluation of Extended-Wear Hearing Technology for Children with Hearing Loss.
Wolfe, Jace; Schafer, Erin; Martella, Natalie; Morais, Mila; Mann, Misty
2015-01-01
Research shows that many older children and teenagers who have mild to moderately severe sensorineural hearing loss do not use their hearing instruments during all waking hours. A variety of reasons may contribute toward this problem, including concerns about cosmetics associated with hearing aid use and the inconvenience of daily maintenance associated with hearing instruments. Extended-wear hearing instruments are inserted into the wearer's ear canal by an audiologist and are essentially invisible to outside observers. The goal of this study was to evaluate the potential benefits and limitations associated with use of extended-wear hearing instruments in a group of children with hearing loss. A two-way repeated measures design was used to examine performance differences obtained with the participants' daily-wear hearing instruments versus that obtained with extended-wear hearing instruments. Sixteen children, ages 10-17 yr old, with sensorineural hearing loss ranging from mild to moderately severe. Probe microphone measures were completed to evaluate the aided output of device. Behavioral test measures included word recognition in quiet, sentence recognition in noise, aided warble-tone thresholds, and psychophysical loudness scaling. Questionnaires were also administered to evaluate subjective performance with each hearing technology. Data logging suggested that many participants were not using their daily-wear hearing instruments during all waking hours (mean use was less than 6 h/day). Real ear probe microphone measurements indicated that a closer fit to the Desired Sensation Level Version 5 prescriptive targets was achieved with the children's daily-wear instruments when compared to the extended-wear instruments. There was no statistically significant difference in monosyllabic word recognition at 50 or 60 dBA obtained with the two hearing technologies. Sentence recognition in noise obtained with use of the extended-wear devices was, however, significantly
Friction and Wear Behavior of Carbon Fabric-Reinforced Epoxy Composites
NASA Astrophysics Data System (ADS)
Şahin, Y.; De Baets, Patrick
2017-12-01
Besides intrinsic material properties, weight/energy savings and wear performance play an important role in the selection of materials for any engineering application. The tribological behavior of carbon fabric-reinforced epoxy composites produced by molding technique was investigated using a reciprocating pin-on-plate configuration. It was shown that the wear rate considerably decreased (by a factor of approx. 8) with the introduction of the reinforcing carbon fabric into the epoxy matrix. It was observed that the wear rate of the tested composites increased with an increase in normal load. Moreover, the coefficient of friction for epoxy/steel and composites/steel tribo-pairs was also determined and decreased with increasing load. By means of scanning electron microscopy of the wear tracks, different wear mechanisms such as matrix wear, matrix fatigue and cracking, matrix debris formation for neat epoxy together with fabric/fiber thinning, fabric breakage and fabric/matrix debonding for the reinforced epoxy could be distinguished.
NASA Astrophysics Data System (ADS)
Gietl, Johanna K.; Lawrence, Roy; Thorpe, Alistair J.; Harrison, Roy M.
2010-01-01
Traffic-generated air pollutant emissions can be classified into exhaust and non-exhaust emissions. Increased attention is focussing on non-exhaust emissions as exhaust emissions are progressively limited by regulations. To characterise metal-rich emission from abrasion processes, size-segregated analysis of atmospheric aerosol particles sampled with micro-orifice uniform deposit impactors (MOUDI) in March 2007 in London was performed. The samples were collected at a roadside and a background site and were analysed for Al, Ba, Cu, Fe, Sb, Ti, V, Zn, Ca 2+, K +, Mg 2+, Na +, and NH 4+. Most components showed a clear roadside increment, which was evident as a higher mass concentration and a change in the size distribution. In particular, Fe, Cu, Ba, and Sb correlated highly, indicative of a common traffic-related source. Using complementary information on the fleet composition, vehicle number and average speed, the brake wear emission was calculated using the EMEP/CORINAIR emission database. The total PM 10 and barium emission of the traffic was determined by ratio to NO x whose source strength was estimated from published emission factors. Barium was found to comprise 1.1% of brake wear (PM 10) particles from the traffic fleet as a whole, allowing its use as a quantitative tracer of brake wear emissions at other traffic-influenced sites.
Fretting wear of iron, nickel, and titanium under varied environmental conditions
NASA Technical Reports Server (NTRS)
Bill, R. C.
1979-01-01
Fretting wear experiments were conducted on high-purity iron, nickel and titanium in air under conditions of varied humidity and temperature, and in nitrogen. For iron and titanium, maximum fretting occurred at 10 and 30 percent relative humidity respectively. Nickel showed a minimum in fretting wear at about 10% relative humidity. With increasing temperature, all three metals initially showed reduced fretting wear, with increasing wear observed as temperatures increased beyond 200-300 C. For titanium, dramatically reduced fretting wear was observed at temperatures above 500 C, relatable to a change in oxidation kinetics. All three metals showed much less fretting wear in N2 with the presence of moisture in N2 having a proportionally stronger effect than in air.
Fretting wear of iron, nickel, and titanium under varied environmental conditions
NASA Technical Reports Server (NTRS)
Bill, R. C.
1978-01-01
Fretting wear experiments were conducted on high purity iron, nickel and titanium in air under conditions of varied humidity and temperature, and in nitrogen. For iron and titanium, maximum fretting occurred at 10 and 30 percent relative humidity respectively. Nickel showed a minimum in fretting wear at about 10 percent relative humidity. With increasing temperature, all three metals initially showed reduced fretting wear, with increasing wear observed as temperatures increased beyond 200-300 C. For titanium, dramatically reduced fretting wear was observed at temperatures above 500 C, relatable to a change in oxidation kinetics. All three metals showed much less fretting wear in N2 with the presence of moisture in N2 having a proportionally stronger effect than in air.
Increasing Wearing of Prescription Glasses in Individuals with Mental Retardation
ERIC Educational Resources Information Center
DeLeon, Iser G.; Hagopian, Louis P.; Rodriguez-Catter, Vanessa; Bowman, Lynn G.; Long, Ethan S.; Boelter, Eric W.
2008-01-01
This study evaluated an intervention for promoting wearing of prescription glasses in 4 individuals with mental retardation who had refused to wear their glasses previously. Distraction through noncontingent reinforcement (NCR) increased independent glasses wearing for 1 of the 4 participants. An intervention consisting of NCR, response cost, and…
Yim, Sung Sun; Bang, Hyun Bae; Kim, Young Hwan; Lee, Yong Jae; Jeong, Gu Min; Jeong, Ki Jun
2014-01-01
Antibodies and their derivatives are the most important agents in therapeutics and diagnostics. Even after the significant progress in the technology for antibody screening from huge libraries, it takes a long time to isolate an antibody, which prevents a prompt action against the spread of a disease. Here, we report a new strategy for isolating desired antibodies from a combinatorial library in one day by repeated fluorescence-activated cell sorting (FACS). First, we constructed a library of synthetic human antibody in which single-chain variable fragment (scFv) was expressed in the periplasm of Escherichia coli. After labeling the cells with fluorescent antigen probes, the highly fluorescent cells were sorted by using a high-speed cell sorter, and these cells were reused without regeneration in the next round of sorting. After repeating this sorting, the positive clones were completely enriched in several hours. Thus, we screened the library against three viral antigens, including the H1N1 influenza virus, Hepatitis B virus, and Foot-and-mouth disease virus. Finally, the potential antibody candidates, which show KD values between 10 and 100 nM against the target antigens, could be successfully isolated even though the library was relatively small (∼106). These results show that repeated FACS screening without regeneration of the sorted cells can be a powerful method when a rapid response to a spreading disease is required. PMID:25303314
Surface Modifications for Improved Wear Performance in Artificial Joints: A Review
NASA Astrophysics Data System (ADS)
Sullivan, Stacey J. L.; Topoleski, L. D. Timmie
2015-11-01
Artificial joint replacement is one of the most successful treatments for arthritis. Excellent wear and corrosion resistance, together with high strength and fracture toughness, are fundamental requirements for implant materials. Wear and/or corrosion of the materials used in artificial joints may lead to implant failure. Therefore, hard and wear-resistant materials, like cobalt-chromium-molybdenum and ceramic, are currently used as bearing surfaces. However, even using such hard materials, wear and/or corrosion related failure of artificial joints remains a central concern. One primary goal in orthopedic biomaterials research is to create more wear-resistant surfaces. Different technologies have been used to create new surfaces, or to modify existing surfaces, to prevent wear. It is the intent of this overview first to provide a summary of materials currently used as bearing surfaces in artificial joints, their functions, and their contributions to device longevity. Then, we will discuss advancements in modifying those bearing surfaces to produce more wear-resistant artificial joints.
Study of Erosive Wear Behaviour on SIC/SIC Composites
NASA Astrophysics Data System (ADS)
Suh, Min-Soo
In the field of aerospace propulsion system, erosive wear on continuous silicon carbide (SiC) fibre-reinforced SiC (SiC/SiC) composites is of significant issue to achieve high energy efficiency. This paper proposes a crucial factor and a design guideline of SiC/SiC composites for higher erosion performance regarding cost effectiveness. Fabrication and evaluation of impacts and wear on SiC/SiC composites are successfully carried out. Erosive wear behaviours of the CVI and the LPS composites evidently show that the crucial fabrication factor against solid particle erosion (SPE). Erosive wear mechanisms on various SiC/SiC composites are determined based on the analysis of erosive wear behaviour. Designing guideline for the SiC/SiC composites for pursuit of high erosion performance is also proposed as focusing on the followings; volume fraction of matrix, strength of the matrix, bonding strength, and PyC interface.
Microstructure, mechanical and fretting wear properties of TiC-stainless steel composites
DOE Office of Scientific and Technical Information (OSTI.GOV)
Akhtar, F.; Department of Metallurgical and Materials Engineering, University of Engineering and Technology, Lahore; Guo, S.J.
2008-01-15
This study deals with the processing, microstructure, and wear behavior of TiC-reinforced stainless steel matrix composites, containing 50 to 70 wt.% TiC. Powder technology was used to successfully fabricate the composites. The microstructure of the composite was characterized by scanning electron microscopy. The microstructural study revealed that the TiC particles were distributed uniformly in the steel matrix phase. Interface debonding and microcracks were not observed in the composite. The composite hardness increased with TiC content. The fretting wear resistance of the composites was studied against high speed steel. The wear mechanisms are discussed by means of microscopical observations on themore » worn surfaces. The wear was severe at higher wear loads and lower TiC content. Microplowing of the stainless steel matrix was found to be the dominant wear mechanism. Heavy microplowing and rapid removal of material from the wear surface was observed at high wear load. The variation of wear loss with volume fraction and mean free path of the binder phase is also reported.« less
The prevalence, aetiology and clinical appearance of tooth wear: the Nigerian experience.
Oginni, O; Olusile, A O
2002-08-01
To establish the prevalence and severity of tooth wear among Nigerians and to compare the pattern and aetiology with findings of earlier studies in Western populations. Clinical examinations for tooth wear using the tooth wear index (TWI). The Federal Republic of Nigeria. Patients attending the Dental Hospital, Obafemi Awolowo University Teaching Hospital's Complex Ile-Ife. Attrition, abrasion and erosion. Of the 126 patients with tooth wear 81 had attrition, 20 had abrasion, 9 had erosion and 16 had attrition and abrasion combined. A total of 15,480 tooth surfaces were examined. 2,229 (14.4%) surfaces had tooth wear out of which 1,007 (6.5%) were pathologically worn down. The frequency of tooth wear increased with the age of patients. Most of the pathologically worn surfaces were just one point above maximum acceptable value. The aetiological factors associated with tooth wear are not different from those encountered in Western cultures but the pattern of wear differs. Pathological tooth wear presents as an age related phenomenon and is probably more severe in Nigerians.
NASA Astrophysics Data System (ADS)
Yang, Mao-Sheng; Liu, Xiu-Bo; Fan, Ji-Wei; He, Xiang-Ming; Shi, Shi-Hong; Fu, Ge-Yan; Wang, Ming-Di; Chen, Shu-Fa
2012-02-01
The high temperature self-lubricating wear-resistant NiCr/Cr3C2-30%WS2 coating and wear-resistant NiCr/Cr3C2 coating were fabricated on 0Cr18Ni9 austenitic stainless steel by laser cladding. Phase constitutions and microstructures were investigated, and the tribological properties were evaluated using a ball-on-disc wear tester under dry sliding condition at room-temperature (17 °C), 300 °C and 600 °C, respectively. Results indicated that the laser clad NiCr/Cr3C2 coating consisted of Cr7C3 primary phase and γ-(Fe,Ni)/Cr7C3 eutectic colony, while the coating added with WS2 was mainly composed of Cr7C3 and (Cr,W)C carbides, with the lubricating WS2 and CrS sulfides as the minor phases. The wear tests showed that the friction coefficients of two coatings both decrease with the increasing temperature, while the both wear rates increase. The friction coefficient of laser clad NiCr/Cr3C2-30%WS2 is lower than the coating without WS2 whatever at room-temperature, 300 °C, 600 °C, but its wear rate is only lower at 300 °C. It is considered that the laser clad NiCr/Cr3C2-30%WS2 composite coating has good combination of anti-wear and friction-reducing capabilities at room-temperature up to 300 °C.
Sliding Speed-Dependent Tribochemical Wear of Oxide-Free Silicon
NASA Astrophysics Data System (ADS)
Chen, Lei; Qi, Yaqiong; Yu, Bingjun; Qian, Linmao
2017-06-01
Fundamental understanding of tribochemical wear mechanism of oxide-free single crystalline silicon (without native oxide layer) is essential to optimize the process of ultra-precision surface manufacturing. Here, we report sliding speed-dependent nanowear of oxide-free silicon against SiO2 microspheres in air and in deionized water. When contact pressure is too low to induce Si yield, tribochemical wear occurs with the existence of water molecules and wear volume decreases logarithmically to constant as sliding speed increased. TEM and Raman observations indicate that the dynamics of rupture and reformation of interfacial bonding bridges result in the variation of tribochemical wear of the oxide-free Si with the increase of sliding speed.
Multi technical analysis of wear mechanisms in axial piston pumps
NASA Astrophysics Data System (ADS)
Schuhler, G.; Jourani, A.; Bouvier, S.; Perrochat, J.-M.
2017-05-01
Axial piston pumps convert a motor rotation motion into hydraulic or pneumatic power. Their compactness and efficiency of approximately 0.9 make them suitable for actuation applications especially in aeronautics. However, they suffer a limited life due to the wear of their components. In the literature, studies of axial piston pumps deal with contact between its different elements under lubrication conditions. Nevertheless, they are more focused on analytic or numerical approaches. This study consists in an experimental analysis of worn pump components to highlight and understand wear mechanisms. Piston shoes are central components in the axial piston pump since they are involved in three tribological contacts. These three contacts are thereby studied: piston shoes/swashplate, piston shoes/pistons and piston shoes/shoes hold down plate (SHDP). To perform this analysis, helicopter hydraulic pumps after different operating times have been studied. The wear damage mechanisms and wear debris are analysed using SEM observations. 3D surface roughness measurements are then used to characterize worn surfaces. The observations reveal that in the contact between shoes and swashplate, the main wear mechanism is three-body abrasive wear due to coarse carbides removal. Between shoes and pistons, wear occurs in a less severe way and is mainly due to the debris generated in the first contact and conveyed by the lubricating fluid. In the third contact, the debris are also the prime cause of the abrasive wear and the generation of deep craters in the piston shoes.
In Vitro Wear Resistance of Nano-Hybrid Composite Denture Teeth.
Munshi, Nabeel; Rosenblum, Marc; Jiang, Shuying; Flinton, Robert
2017-04-01
To evaluate the wear resistance of nano-hybrid composite denture teeth as compared to two commonly used denture teeth: interpenetrating polymer network (IPN) and double crosslinking polymethylmethacrylate (PMMA) denture teeth. 18 styli and 18 disk specimens were prepared from the three denture tooth materials: nano-hybrid composite, IPN, and double crosslinking PMMA. The specimens were mounted in a two-body wear testing machine to simulate chewing in the complete denture. The amount of wear from the styli specimens were measured before and after using a digital micrometer, and the depth of the wear track from the disk specimens was measured using a noncontact 3D optical profilometer. The total wear from each denture tooth group was compared using one-way ANOVA with a 0.05 significance level. A Tukey post hoc test was used to determine differences between the three groups. The mean total wear in the nano-hybrid composite teeth group was 1.16 mm, SD = 0.5 mm, statistically significantly higher (p ≤ 0.0001) than the IPN (mean = 0.13 mm, SD = 0.05) and double crosslinking PMMA tooth groups (mean = 0.31 mm, SD = 0.19). There was no statistically significant difference between IPN denture teeth and double crosslinking PMMA denture teeth in the amount of wear. Nano-hybrid composite denture teeth exhibited statistically significantly more wear than the IPN and double crosslinking PMMA denture teeth. © 2015 by the American College of Prosthodontists.
Tibiofemoral wear in standard and non-standard squat: implication for total knee arthroplasty.
Fekete, Gusztáv; Sun, Dong; Gu, Yaodong; Neis, Patric Daniel; Ferreira, Ney Francisco; Innocenti, Bernardo; Csizmadia, Béla M
2017-01-01
Due to the more resilient biomaterials, problems related to wear in total knee replacements (TKRs) have decreased but not disappeared. In the design-related factors, wear is still the second most important mechanical factor that limits the lifetime of TKRs and it is also highly influenced by the local kinematics of the knee. During wear experiments, constant load and slide-roll ratio is frequently applied in tribo-tests beside other important parameters. Nevertheless, numerous studies demonstrated that constant slide-roll ratio is not accurate approach if TKR wear is modelled, while instead of a constant load, a flexion-angle dependent tibiofemoral force should be involved into the wear model to obtain realistic results. A new analytical wear model, based upon Archard's law, is introduced, which can determine the effect of the tibiofemoral force and the varying slide-roll on wear between the tibiofemoral connection under standard and non-standard squat movement. The calculated total wear with constant slide-roll during standard squat was 5.5 times higher compared to the reference value, while if total wear includes varying slide-roll during standard squat, the calculated wear was approximately 6.25 times higher. With regard to non-standard squat, total wear with constant slide-roll during standard squat was 4.16 times higher than the reference value. If total wear included varying slide-roll, the calculated wear was approximately 4.75 times higher. It was demonstrated that the augmented force parameter solely caused 65% higher wear volume while the slide-roll ratio itself increased wear volume by 15% higher compared to the reference value. These results state that the force component has the major effect on wear propagation while non-standard squat should be proposed for TKR patients as rehabilitation exercise.
Tibiofemoral wear in standard and non-standard squat: implication for total knee arthroplasty
Sun, Dong; Gu, Yaodong; Neis, Patric Daniel; Ferreira, Ney Francisco; Innocenti, Bernardo; Csizmadia, Béla M.
2017-01-01
Summary Introduction Due to the more resilient biomaterials, problems related to wear in total knee replacements (TKRs) have decreased but not disappeared. In the design-related factors, wear is still the second most important mechanical factor that limits the lifetime of TKRs and it is also highly influenced by the local kinematics of the knee. During wear experiments, constant load and slide-roll ratio is frequently applied in tribo-tests beside other important parameters. Nevertheless, numerous studies demonstrated that constant slide-roll ratio is not accurate approach if TKR wear is modelled, while instead of a constant load, a flexion-angle dependent tibiofemoral force should be involved into the wear model to obtain realistic results. Methods A new analytical wear model, based upon Archard’s law, is introduced, which can determine the effect of the tibiofemoral force and the varying slide-roll on wear between the tibiofemoral connection under standard and non-standard squat movement. Results The calculated total wear with constant slide-roll during standard squat was 5.5 times higher compared to the reference value, while if total wear includes varying slide-roll during standard squat, the calculated wear was approximately 6.25 times higher. With regard to non-standard squat, total wear with constant slide-roll during standard squat was 4.16 times higher than the reference value. If total wear included varying slide-roll, the calculated wear was approximately 4.75 times higher. Conclusions It was demonstrated that the augmented force parameter solely caused 65% higher wear volume while the slide-roll ratio itself increased wear volume by 15% higher compared to the reference value. These results state that the force component has the major effect on wear propagation while non-standard squat should be proposed for TKR patients as rehabilitation exercise. PMID:29721453
A fundamental review of the friction and wear behavior of ceramics
NASA Technical Reports Server (NTRS)
Buckley, D. H.
1972-01-01
The basic concepts associated with the friction and wear of materials are discussed as they relate to ceramics. Properties of ceramics such as crystal structure, crystallographic orientation, mechanical deformation, and surface chemistry are reviewed as they influence friction and wear. Both adhesive and abrasive wear of ceramics are discussed. The friction and wear of ceramics are examined in contact with themselves and when in contact with metals. The influences of environmental constituents such as water and hydrocarbons on friction and wear are reviewed. Materials discussed, by way of example, include aluminum oxide, rutile, calcium fluoride, and lithium fluoride.
Dental Wear: Attrition, Erosion, and Abrasion-A Palaeo-Odontological Approach.
Sperber, Geoffrey H
2017-06-17
This paper reviews the surface ablation of early hominin teeth by attrition, abrasion, and erosive dental wear. The occurrence of these lesions is explored in a sample of South African fossil australopithecine dentitions revealing excessive wear. Interpretation of the nature of the dietary components causing such wear in the absence of carious erosion provides insight into the ecology of the Plio-pleistocene epoch (1-2 million years ago). Fossil teeth inform much of the living past by their retained evidence after death. Tooth wear is the ultimate forensic dental evidence of lives lived.
The Tyne and Wear Metro development proposal : 2011.
DOT National Transportation Integrated Search
2011-01-01
Metro is the main mode of public transport of Tyne and Wear Conurbation. : During last 5 years there was steady growth of passenger traffic volume. But now : 350 000 inhabitants of the Tyne and Wear, and 290 thousand inhabitants of : Northumberland a...
Fracture mechanics approach to estimate rail wear limits
DOT National Transportation Integrated Search
2009-10-01
This paper describes a systematic methodology to estimate allowable limits for rail head wear in terms of vertical head-height loss, gage-face side wear, and/or the combination of the two. This methodology is based on the principles of engineering fr...
New Challenges in Tribology: Wear Assessment Using 3D Optical Scanners.
Valigi, Maria Cristina; Logozzo, Silvia; Affatato, Saverio
2017-05-18
Wear is a significant mechanical and clinical problem. To acquire further knowledge on the tribological phenomena that involve freeform mechanical components or medical prostheses, wear tests are performed on biomedical and industrial materials in order to solve or reduce failures or malfunctions due to material loss. Scientific and technological advances in the field of optical scanning allow the application of innovative devices for wear measurements, leading to improvements that were unimaginable until a few years ago. It is therefore important to develop techniques, based on new instrumentations, for more accurate and reproducible measurements of wear. The aim of this work is to discuss the use of innovative 3D optical scanners and an experimental procedure to detect and evaluate wear, comparing this technique with other wear evaluation methods for industrial components and biomedical devices.
Mechanical and wear properties of aluminum coating prepared by cold spraying
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yusof, Siti Nurul Akmal, E-mail: em-leo277@yahoo.com; Manap, Abreeza, E-mail: Abreeza@uniten.edu.my; Afandi, Nurfanizan Mohd
In this study, aluminum (Al) powders were deposited onto Al substrates using cold spray to form a coating. The main objective is to investigate and compare the microstructure, mechanical and wear properties of Al coating to that of the Al substrate. The microstructure of the coating and substrate were observed using Scanning Electron Microscope (SEM). Hardness was evaluated using the Vickers Hardness test and wear properties were investigated using a pin-on-disk wear test machine. The elemental composition of the coating and substrate was determined using Energy-dispersive X-ray spectroscopy (EDX). Results showed that the friction coefficient and specific wear rate decreasedmore » while wear rate increased linearly with increasing load. It was found that the coating exhibit slightly better mechanical and wear properties compared to the substrate.« less
Friction and Wear Behavior of Selected Dental Ceramics
NASA Astrophysics Data System (ADS)
Park, Jongee; Pekkan, Gurel; Ozturk, Abdullah
The purpose of this study was to determine the friction coefficients and wear rates of six commercially available dental ceramics including IPS Empress 2 (E2), Cergo Pressable Ceramic (CPC), Cercon Ceram (CCS) and Super porcelain EX-3 (SPE). Bovine enamel (BE) was also tested as a reference material for comparison purposes. Samples of the dental ceramics were prepared according to the instructions described by the manufacturers in disk-shape with nominal dimensions of 12 mm × 2 mm. The wear tests were performed by means of a pin-on-disk type tribometer. The friction coefficients and specific wear rates of the materials were determined at a load of 10 N and rotating speed of 0.25 cm/s without lubrication. Surface morphology of the wear tracks was examined using a scanning electron microscope. Statistical analyses were made using one-way ANOVA and Turkey's HSD (P < 0.05).
Permethrin exposure from fabric-treated military uniforms under different wear-time scenarios.
Proctor, Susan P; Maule, Alexis L; Heaton, Kristin J; Adam, Gina E
2014-11-01
The objective of the project was to ascertain whether urinary biomarkers of permethrin exposure are detected after wearing post-tailored, fabric-treated military uniforms under two different wear-time exposure scenarios. Study A occurred over 3.5 days and involved six participants wearing treated uniforms continuously for 30-32 h. Urine collection occurred at scheduled time points before, during, and after wearing the uniform. Study B, conducted over 19 days, included 11 participants wearing treated uniforms for 3 consecutive days, 8 h each day (with urine collection before, during, and after wear). Urinary biomarkers of permethrin (3-phenoxybenzoic acid (3PBA), cis- 2,2-(dichlorovinyl)-2,2-dimethylcyclopropane-1-carboxylic acid (cDCCA), trans- 2,2-(dichlorovinyl)-2,2-dimethylcyclopropane-1-carboxylic acid (tDCCA)) were detected during and after wear. Biomarker detection generally occurred over the 10- to 12-h period after putting on the uniform and subsided 24 h following uniform removal (in both Study A and B scenarios). Those wearing permethrin-treated uniforms under the longer wear-time scenario (Study A) excreted significantly higher cumulative mean levels compared with those in Study B (3.29 times higher for 3PBA and 2.23 times higher for the sum of c/tDCCA (P≤0.001)). Findings suggest that wearing permethrin-treated clothing does increase absorbed, internal dose levels of permethrin above population levels and is significantly related to wear-time duration.
Incisal tooth wear and self-reported TMD pain in children and adolescents.
Hirsch, Christian; John, Mike T; Lobbezoo, Frank; Setz, Juergen M; Schaller, Hans-Guenter
2004-01-01
Incisal tooth wear may be a sign of long-term bruxing behavior. Bruxism is purported to be a risk factor for temporomandibular disorders (TMD). The aim of this population-based cross-sectional study was to determine if anterior tooth wear is associated with the self-report of TMD pain in children and adolescents. In a population sample of 1,011 children and adolescents (mean age 13.1 years, range 10 to 18 years; female 52%; response rate 85%), TMD cases were defined as subjects reporting pain in the face, jaw muscles, and temporomandibular joint during the last month according to RDC/TMD. All other subjects were considered controls. Incisal tooth wear was assessed in the clinical examination using a 0 to 2 scale (no wear, enamel wear, dentin wear) for every anterior permanent tooth. The mean wear score for the individuals was categorized into 0, 0.01 to 0.20, 0.21 to 0.40, and 0.41+. A multiple logistic regression analysis, controlling for the effects of age and gender, analyzed the association between the categorized summary wear score and TMD. Specifically, the hypothesis of a trend between higher tooth wear scores and higher risk of TMD was tested. An odds ratio of 1.1 indicated, after adjusting for gender and age, no statistically significantly higher risk of TMD pain with higher tooth wear scores. Incisal tooth wear was not associated with self-reported TMD pain in 10- to 18-year-old subjects.
Friction and wear of radiofrequency-sputtered borides, silicides, and carbides
NASA Technical Reports Server (NTRS)
Brainard, W. A.; Wheeler, D. R.
1978-01-01
The friction and wear properties of several refractory compound coatings were examined. These compounds were applied to 440 C bearing steel surfaces by radiofrequency (RF) sputtering. The refractory compounds were the titanium and molybdenum borides, the titanium and molybdenum silicides, and the titanium, molybdenum, and boron carbides. Friction testing was done with a pin-on-disk wear apparatus at loads from 0.1 to 5.0 newtons. Generally, the best wear properties were obtained when the coatings were bias sputtered onto 440 C disks that had been preoxidized. Adherence was improved because of the better bonding of the coatings to the iron oxide formed during preoxidation. As a class the carbides provided wear protection to the highest loads. Titanium boride coatings provided low friction and good wear properties to moderate loads.
Tooth wear in three ethnic groups in Sabah (northern Borneo).
Milosevic, A; Lo, M S
1996-12-01
The prevalence and associated aetiologies of tooth wear were investigated in three ethnic groups in Sabah (Northern Borneo) using the Tooth Wear Index (TWI). The number of surfaces with enamel wear only, dentine exposed for less than a third or dentine exposed for more than a third were categorised into the TW minimal, moderate or severe respectively. A structured questionnaire was used to elicit medical/dental history, oral hygiene practices, satisfaction with body image, diet and other personal habits/details. The sample comprised of a self selected sample of 148 dental hospital attenders; 47 (32 per cent) each of ethnic Chinese and Malay and 54 (36 per cent) of ethnic Kadazan, matched for age and with a similar number of scoreable teeth per subject. Dentine exposure within the total sample was a common finding (95 per cent TW with moderate, 41 per cent TW severe). The Kadazan group had significantly (P < 0.05) more surfaces with severe tooth wear than the Chinese or Malay. Tobacco chewing was positively associated (rho = +0.4, P < 0.05) with both moderate and severe tooth wear, as was the habit of crushing/eating bones. Neither carbonated beverages or fresh fruit intake were associated with tooth wear, but their frequency of consumption was low. The buccal and occlusal surfaces of the posterior teeth were the most severely worn. Generally, wear was greater in the upper anterior sextant compared to the lower anterior sextant, with the exception of the lower incisal edges in the Kadazan group. Tooth wear into dentine was a common occurrence, especially among the Kadazan subjects and least among the Chinese subjects. The aetiological factors associated with this tooth wear are different to those encountered in Western cultures.
Crystal structure of fac-aquatricarbonyl[(S)-valin-ato-κ(2) N,O]-rhenium(I).
Piletska, Kseniia O; Domasevitch, Kostiantyn V; Shtemenko, Alexander V
2016-04-01
In the mol-ecule of the title compound, [Re(C5H10NO2)(CO)3(H2O)], the Re(I) atom adopts a distorted octa-hedral coordination sphere defined by one aqua and three carbonyl ligands as well as one amino N and one carboxyl-ate O atom of the chelating valinate anion. The carbonyl ligands are arranged in a fac-configuration around the Re(I) ion. In the crystal, an intricate hydrogen-bonding system under participation of two O-H, two N-H and one C-H donor groups and the carboxyl-ate and carbonyl O atoms as acceptor groups contribute to the formation of a three-dimensional supra-molecular network.
Bratsos, Ioannis; Simonin, Camilla; Zangrando, Ennio; Gianferrara, Teresa; Bergamo, Alberta; Alessio, Enzo
2011-10-07
The Ru(II) complex fac-[RuCl(dmso-S)(3)(dmso-O)(2)][PF(6)] (P2) was found to be an excellent precursor for the facile preparation in high yield of half sandwich-type compounds of the general formula fac-[RuCl(dmso-S)(3)(N)(2)][PF(6)] (e.g. (N)(2) = 1,2-diaminoethane (en, 4), trans-1,2-diaminocyclohexane (dach, 5), or 2 NH(3) (6)). Neutral half sandwich-type compounds of the general formula fac-[RuCl(dmso-S)(3)(N-O)] where N-O is an anionic chelating ligand (e.g. N-O = picolinate (pic, 7)) are best prepared from the universal Ru(II)-dmso precursor cis-[RuCl(2)(dmso)(4)] (P1). These complexes, that were fully characterized in solution and in the solid state, are structurally similar to the anticancer organometallic compounds [Ru(η(6)-arene)(chel)Cl][PF(6)](n) but, in place of a face-capping arene, have the fac-Ru(dmso-S)(3) fragment. In contrast to what observed for the corresponding arene compounds, that rapidly hydrolyze the Cl ligand upon dissolution in water, compounds 4-6 are very stable and inert in aqueous solution. Probably their inertness is the reason why they showed no significant cytotoxicity against the MDA-MB-231 cancer cell line.
Effect of soot on oil properties and wear of engine components
NASA Astrophysics Data System (ADS)
Green, D. A.; Lewis, R.
2007-09-01
The objective of the work outlined in this paper was to increase the understanding of the wear mechanisms that occur within a soot contaminated contact zone, to help in future development of a predictive wear model to assist in the automotive engine valve train design process. The paper builds on previous work by the author, through testing of different lubricants and increased levels of soot contamination. Wear testing has been carried out using specimens operating under realistic engine conditions, using a reciprocating test-rig specifically designed for this application, where a steel disc is held in a heated bath of oil and a steel ball is attached to a reciprocating arm (replicating a sliding elephant's foot valve train contact). Detailed analysis of the test specimens has been performed using scanning electron microscopy to identify wear features relating to the proposed wear mechanisms. Analysis of worn engine components from durability engine tests has also been carried out for a comparison between specimen tests and engine testing. To assist the understanding of the wear test results obtained, the physical properties of contaminated lubricants were investigated, through viscosity, traction and friction measurements. The results have revealed how varying lubrication conditions change the wear rate of engine components and determine the wear mechanism that dominates in specific situations. Testing has also shown the positive effects of advanced engine lubricants to reduce the amount of wear produced with soot present.
Factors related to seatbelt-wearing among rear-seat passengers in Malaysia.
Ng, Choy Peng; Law, Teik Hua; Wong, Shaw Voon; Kulanthayan, S
2013-01-01
The benefit of wearing a rear seatbelt in reducing the risk of motor vehicle crash-related fatalities and injuries has been well documented in previous studies. Wearing a seatbelt not only reduces the risk of injury to rear-seat passengers, but also reduces the risk of injury to front-seat occupant who could be crushed by unbelted rear-seat passengers in a motor vehicle crash. Despite the benefits of wearing a rear seatbelt, its rate of use in Malaysia is generally low. The objective of this study was to identify factors that are associated with the wearing of a seatbelt among rear-seat passengers in Malaysia. Multinomial logistic regression analysis of the results of a questionnaire survey of 1651 rear-seat passengers revealed that rear-seat passengers who were younger, male, single and less educated and who had a perception of a low level of legislation enforcement, a lower risk-aversion and less driving experience (only for passengers who are also drivers) were less likely to wear a rear seatbelt. There was also a significant positive correlation between driver seatbelt and rear seatbelt-wearing behaviour. This implies that, in regards to seatbelt-wearing behaviour, drivers are more likely to adopt the same seatbelt-wearing behaviour when travelling as rear-seat passengers as they do when driving. These findings are crucial to the development of new interventions to increase the compliance rate of wearing a rear seatbelt. Copyright © 2012 Elsevier Ltd. All rights reserved.
Polyethylene wear of mobile-bearing unicompartmental knee replacement at 20 years.
Kendrick, B J L; Simpson, D J; Kaptein, B L; Valstar, E R; Gill, H S; Murray, D W; Price, A J
2011-04-01
The Oxford unicompartmental knee replacement (UKR) was designed to minimise wear utilising a fully-congruent, mobile, polyethylene bearing. Wear of polyethylene is a significant cause of revision surgery in UKR in the first decade, and the incidence increases in the second decade. Our study used model-based radiostereometric analysis to measure the combined wear of the upper and lower bearing surfaces in 13 medial-compartment Oxford UKRs at a mean of 20.9 years (17.2 to 25.9) post-operatively. The mean linear penetration of the polyethylene bearing was 1.04 mm (0.307 to 2.15), with a mean annual wear rate of 0.045 mm/year (0.016 to 0.099). The annual wear rate of the phase-2 bearings (mean 0.022 mm/year) was significantly less (p = 0.01) than that of phase-1 bearings (mean 0.07 mm/year). The linear wear rate of the Oxford UKR remains very low into the third decade. We believe that phase-2 bearings had lower wear rates than phase-1 implants because of the improved bearing design and surgical technique which decreased the incidence of impingement. We conclude that the design of the Oxford UKR gives low rates of wear in the long term.
Comparative study of the wear behavior of composites for posterior restorations.
Turssi, Cecilia P; Faraoni-Romano, Juliana J; de Menezes, Márcio; Serra, Mônica C
2007-01-01
This investigation sought to compare the abrasive wear rates of resin composites designed for posterior applications. Seventy-five specimens were fabricated with conventional hybrid (Charisma and Filtek Z250) or packable composites (Filtek P60, Solitaire II and Tetric Ceram HB), according to a randomized complete block design (n = 15). Specimens were finished and polished metallographically and subjected to abrasive wear which was performed under a normal load of 13N at a frequency of 2 Hz using a pneumatic device (MSM/Elquip) in the presence of a mucin-containing artificial saliva. Wear was quantified profilometrically in five different locations of each specimen after 1,000, 5,000, 10,000, 50,000 and after every each 50,000 through 250,000 cycles. A split-plot ANOVA showed a significant difference between the wear resistance of composites (alpha = 0.05). Tukey's test ascertained that while the composites Filtek Z250 and Charisma wore significantly less than any other of the materials tested, Tetric Ceram HB experienced the greatest wear rates. Filtek P60 and Solitaire II showed intermediate rates of material removal. The wear pattern of composites proved to be biphasic with the primary phase having the faster wear rate. In conclusion, packable resin composites may not have superior wear compared to conventional hybrid composites.
An Investigation of the Wear on Silicon Surface at High Humidity.
Wang, Xiaodong; Guo, Jian; Xu, Lin; Cheng, Guanggui; Qian, Linmao
2018-06-16
Using an atomic force microscope (AFM), the wear of monocrystalline silicon (covered by a native oxide layer) at high humidity was investigated. The experimental results indicated that tribochemistry played an important role in the wear of the silicon at different relative humidity levels (RH = 60%, 90%). Since the tribochemical reactions were facilitated at 60% RH, the wear of silicon was serious and the friction force was around 1.58 μN under the given conditions. However, the tribochemical reactions were restrained when the wear pair was conducted at high humidity. As a result, the wear of silicon was very slight and the friction force decreased to 0.85 μN at 90% RH. The slight wear of silicon at high humidity was characterized by etching tests. It was demonstrated that the silicon sample surface was partly damaged and the native oxide layer on silicon sample surface had not been totally removed during the wear process. These results may help us optimize the tribological design of dynamic microelectromechanical systems working in humid conditions.
New Challenges in Tribology: Wear Assessment Using 3D Optical Scanners
Valigi, Maria Cristina; Logozzo, Silvia; Affatato, Saverio
2017-01-01
Wear is a significant mechanical and clinical problem. To acquire further knowledge on the tribological phenomena that involve freeform mechanical components or medical prostheses, wear tests are performed on biomedical and industrial materials in order to solve or reduce failures or malfunctions due to material loss. Scientific and technological advances in the field of optical scanning allow the application of innovative devices for wear measurements, leading to improvements that were unimaginable until a few years ago. It is therefore important to develop techniques, based on new instrumentations, for more accurate and reproducible measurements of wear. The aim of this work is to discuss the use of innovative 3D optical scanners and an experimental procedure to detect and evaluate wear, comparing this technique with other wear evaluation methods for industrial components and biomedical devices. PMID:28772905
Wear resistance of polypropylene-SiC composite
NASA Astrophysics Data System (ADS)
Abenojar, J.; Enciso, B.; Martínez, MA; Velasco, F.
2017-05-01
In this work, the wear resistance of thermoplastic composites with a high amount of ceramic is evaluated. Composites made of polypropylene (PP) and silicon carbide (SiC) powder at 50 wt% were used with the final objective of manufacturing ablative materials. This is the first part of a project studying the wear resistance and the mechanical properties of those composites, to be used in applications like habitat industry. In theory, the exposure to high temperature of ablative materials involves the elimination of thermal energy by the sacrifice of surface polymer. In our case, PP will act as a heat sink, up to the reaction temperature (melting or sublimation), where endothermic chemical decomposition into charred material and gaseous products occurs. As the surface is eroded, it is formed a SiC like-foam with improved insulation performance. Composites were produced by extrusion and hot compression. The wear characterization was performed by pin-on-disk test. Wear test was carried out under standard ASTM G99. The parameters were 120 rpm speed, 15 N load, a alumina ball with 6 mm as pin and 1000 m sliding distance. The tracks were also observed by opto-digital microscope.
Tooth wear: the view of the anthropologist
2007-01-01
Anthropologists have for many years considered human tooth wear a normal physiological phenomenon where teeth, although worn, remain functional throughout life. Wear was considered pathological only if pulpal exposure or premature tooth loss occurred. In addition, adaptive changes to the stomatognathic system in response to wear have been reported including continual eruption, the widening of the masticatory cycle, remodelling of the temporomandibular joint and the shortening of the dental arches from tooth migration. Comparative studies of many different species have also documented these physiological processes supporting the idea of perpetual change over time. In particular, differential wear between enamel and dentine was considered a physiological process relating to the evolution of the form and function of teeth. Although evidence of attrition and abrasion has been known to exist among hunter-gatherer populations for many thousands of years, the prevalence of erosion in such early populations seems insignificant. In particular, non-carious cervical lesions to date have not been observed within these populations and therefore should be viewed as ‘modern-day’ pathology. Extrapolating this anthropological perspective to the clinical setting has merits, particularly in the prevention of pre-mature unnecessary treatment. PMID:17938977
Tooth wear: the view of the anthropologist.
Kaidonis, John A
2008-03-01
Anthropologists have for many years considered human tooth wear a normal physiological phenomenon where teeth, although worn, remain functional throughout life. Wear was considered pathological only if pulpal exposure or premature tooth loss occurred. In addition, adaptive changes to the stomatognathic system in response to wear have been reported including continual eruption, the widening of the masticatory cycle, remodelling of the temporomandibular joint and the shortening of the dental arches from tooth migration. Comparative studies of many different species have also documented these physiological processes supporting the idea of perpetual change over time. In particular, differential wear between enamel and dentine was considered a physiological process relating to the evolution of the form and function of teeth. Although evidence of attrition and abrasion has been known to exist among hunter-gatherer populations for many thousands of years, the prevalence of erosion in such early populations seems insignificant. In particular, non-carious cervical lesions to date have not been observed within these populations and therefore should be viewed as 'modern-day' pathology. Extrapolating this anthropological perspective to the clinical setting has merits, particularly in the prevention of pre-mature unnecessary treatment.
Lemorini, Cristina; Plummer, Thomas W; Braun, David R; Crittenden, Alyssa N; Ditchfield, Peter W; Bishop, Laura C; Hertel, Fritz; Oliver, James S; Marlowe, Frank W; Schoeninger, Margaret J; Potts, Richard
2014-07-01
Evidence of Oldowan tools by ∼2.6 million years ago (Ma) may signal a major adaptive shift in hominin evolution. While tool-dependent butchery of large mammals was important by at least 2.0 Ma, the use of artifacts for tasks other than faunal processing has been difficult to diagnose. Here we report on use-wear analysis of ∼2.0 Ma quartz and quartzite artifacts from Kanjera South, Kenya. A use-wear framework that links processing of specific materials and tool motions to their resultant use-wear patterns was developed. A blind test was then carried out to assess and improve the efficacy of this experimental use-wear framework, which was then applied to the analysis of 62 Oldowan artifacts from Kanjera South. Use-wear on a total of 23 artifact edges was attributed to the processing of specific materials. Use-wear on seven edges (30%) was attributed to animal tissue processing, corroborating zooarchaeological evidence for butchery at the site. Use-wear on 16 edges (70%) was attributed to the processing of plant tissues, including wood, grit-covered plant tissues that we interpret as underground storage organs (USOs), and stems of grass or sedges. These results expand our knowledge of the suite of behaviours carried out in the vicinity of Kanjera South to include the processing of materials that would be 'invisible' using standard archaeological methods. Wood cutting and scraping may represent the production and/or maintenance of wooden tools. Use-wear related to USO processing extends the archaeological evidence for hominin acquisition and consumption of this resource by over 1.5 Ma. Cutting of grasses, sedges or reeds may be related to a subsistence task (e.g., grass seed harvesting, cutting out papyrus culm for consumption) and/or a non-subsistence related task (e.g., production of 'twine,' simple carrying devices, or bedding). These results highlight the adaptive significance of lithic technology for hominins at Kanjera. Copyright © 2014 Elsevier Ltd. All
Effect of humidity on fretting wear of several pure metals
NASA Technical Reports Server (NTRS)
Goto, H.; Buckley, D. H.
1984-01-01
Fretting wear experiments with several pure metals were conducted in air at various relative humidity levels. The materials used were iron, aluminum, copper, silver, chromium, titanium, and nickel. Each pure metal had a maximum fretting wear volume at a specific humidity level RH sub max that was not dependent on mechanical factors such as contact load, fretting amplitude, and frequency in the ranges studied. The weight loss due to fretting wear at RH sub max for each pure metal decreased with increasing heat of oxygen adsorption on the metal, indicating that adhesive wear dominated at RH sub max.
Influence of alloying elements on friction and wear of copper
NASA Technical Reports Server (NTRS)
Buckley, D. H.
1972-01-01
The friction and wear characteristics were determined for copper binary alloys containing 10 atomic percent aluminum, silicon, indium, and tin. A ternary alloy containing 10 atomic percent aluminum and 5 atomic percent silicon was also examined. The effectiveness of each of the alloying elements aluminum and silicon were very effective in reducing friction. Silicon, however, also reduced wear appreciably. With lubrication, silicon, indium, and tin were all effective alloying elements in reducing friction and wear from values obtained for copper. Silicon was the most effective single element in reducing friction and wear in dry sliding and with lubrication.
Dental Wear: Attrition, Erosion, and Abrasion—A Palaeo-Odontological Approach
Sperber, Geoffrey H.
2017-01-01
This paper reviews the surface ablation of early hominin teeth by attrition, abrasion, and erosive dental wear. The occurrence of these lesions is explored in a sample of South African fossil australopithecine dentitions revealing excessive wear. Interpretation of the nature of the dietary components causing such wear in the absence of carious erosion provides insight into the ecology of the Plio-pleistocene epoch (1–2 million years ago). Fossil teeth inform much of the living past by their retained evidence after death. Tooth wear is the ultimate forensic dental evidence of lives lived. PMID:29563425
Patterns of tooth wear associated with methamphetamine use.
Richards, J R; Brofeldt, B T
2000-08-01
Methamphetamine (MAP) abuse is a significant worldwide problem. This prospective study was conducted to determine if MAP users had distinct patterns of tooth wear. Methamphetamine users were identified and interviewed about their duration and preferred route of MAP use. Study participants were interviewed in the emergency department of a large urban university hospital serving a geographic area with a high rate of illicit MAP production and consumption. Tooth wear was documented for each study participant and scored using a previously validated index and demographic information was obtained using a questionnaire. Forty-three MAP patients were interviewed. Preferred route of administration was injection (37%) followed by snorting (33%). Patients who preferentially snorted MAP had significantly higher tooth wear in the anterior maxillary teeth than patients who injected, smoked, or ingested MAP (P = 0.005). Patients who use MAP have distinct patterns of wear based on route of administration. This difference may be explained anatomically.
A comparative study of progressive wear of four dental monolithic, veneered glass-ceramics.
Zhang, Zhenzhen; Yi, Yuanping; Wang, Xuesong; Guo, Jiawen; Li, Ding; He, Lin; Zhang, Shaofeng
2017-10-01
This study evaluated the wear performance and wear mechanisms of four dental glass-ceramics, based on the microstructure and mechanical properties in the progressive wear process. Bar (N = 40, n = 10) and disk (N = 32, n = 8) specimens were prepared from (A) lithium disilicate glass-ceramic (LD), (B) leucite reinforced glass-ceramic (LEU), (C) feldspathic glass-ceramic (FEL), and (D) fluorapatite glass-ceramic (FLU). The bar specimens were tested for three-point flexural strength, hardness, fracture toughness and elastic modulus. The disk specimens paired with steatite antagonists were tested in a pin-on-disk tribometer with 10N up to 1000,000 wear cycles. The wear analysis of glass-ceramics was performed using a 3D profilometer after every 200,000 wear cycles. Wear loss of steatite antagonists was calculated by measuring the weight and density using sensitive balance and Archimedes' method. Wear morphologies and microstructures were analyzed by scanning electron microscopy (SEM). The crystalline phase compositions were determined using X-ray diffraction (XRD). One-way analysis of variance (ANOVA) was used to analyze the data. Multiple pair-wise comparison of means was performed by Tukey's post-hoc test. LD showed the highest fracture toughness, flexural strength, elastic modulus and crystallinity, followed by LEU and FEL, and FLU showed the lowest. However, the hardness of LD was lower than all the other three types of ceramics. For steatite antagonists, LD produced the least wear loss of antagonist, followed by LEU and FEL, and FLU had the most wear loss. For glass-ceramic materials, LD exhibited similar wear loss as LEU, but more than FLU and FEL did. Moreover, fracture occurred on the wear surface of FLU. In the progressive wear process, veneering porcelains showed better wear resistance but fluorapatite veneering porcelains appeared fracture surface. Monolithic lithium disilicate glass-ceramics with higher mechanical properties showed more wear loss, however
Wear of Steel and Ti6Al4V Rollers in Vacuum
NASA Technical Reports Server (NTRS)
Krantz, Timothy L.; Shareef, Iqbal
2012-01-01
This investigation was prompted by results of a qualification test of a mechanism to be used for the James Webb Space Telescope. Post-test inspections of the qualification test article revealed some loose wear debris and wear of the steel rollers and the mating Ti6Al4V surfaces. An engineering assessment of the design and observations from the tested qualification unit suggested that roller misalignment was a controlling factor. The wear phenomena were investigated using dedicated laboratory experiments. Tests were done using a vacuum roller rig for a range of roller misalignment angles. The wear in these tests was mainly adhesive wear. The measured wear rates were highly correlated to the misalignment angle. For all tests with some roller misalignment, the steel rollers lost mass while the titanium rollers gained mass indicating strong adhesion of the steel with the titanium alloy. Inspection of the rollers revealed that the adhesive wear was a two-way process as titanium alloy was found on the steel rollers and vice versa. The qualification test unit made use of 440F steel rollers in the annealed condition. Both annealed 440F steel rollers and hardened 440C rollers were tested in the vacuum roller rig to investigate possibility to reduce wear rates and the risk of loose debris formation. The 440F and 440C rollers had differing wear behaviors with significantly lesser wear rates for the 440C. For the test condition of zero roller misalignment, the adhesive wear rates were very low, but still some loose debris was formed
Effect of motion inputs on the wear prediction of artificial hip joints
Liu, Feng; Fisher, John; Jin, Zhongmin
2013-01-01
Hip joint simulators have been largely used to assess the wear performance of joint implants. Due to the complexity of joint movement, the motion mechanism adopted in simulators varies. The motion condition is particularly important for ultra-high molecular weight polyethylene (UHMWPE) since polyethylene wear can be substantially increased by the bearing cross-shear motion. Computational wear modelling has been improved recently for the conventional UHMWPE used in total hip joint replacements. A new polyethylene wear law is an explicit function of the contact area of the bearing and the sliding distance, and the effect of multidirectional motion on wear has been quantified by a factor, cross-shear ratio. In this study, the full simulated walking cycle condition based on a walking measurement and two simplified motions, including the ISO standard motion and a simplified ProSim hip simulator motion, were considered as the inputs for wear modelling based on the improved wear model. Both the full simulation and simplified motions generated the comparable multidirectional motion required to reproduce the physiological wear of the bearing in vivo. The predicted volumetric wear of the ProSim simulator motion and the ISO motion conditions for the walking cycle were 13% and 4% lower, respectively, than that of the measured walking condition. The maximum linear wear depths were almost the same, and the areas of the wear depth distribution were 13% and 7% lower for the ProSim simulator and the ISO condition, respectively, compared with that of the measured walking cycle motion condition. PMID:25540472
Wear rates of artificial denture teeth opposed by natural dentition.
Douglas, W H; Delong, R; Pintado, M R; Latta, M A
1993-01-01
The wear rate of polymeric or composite-based artificial denture teeth on fixed, removable and implant prostheses is important in the maintenance of cuspal form, masticatory efficiency and occlusal stability. A servo-hydraulic based artificial mouth in which an occlusion was established between artificial denture teeth, and the palatal cusp of a human maxillary third molar was established and used to assess the wear resistance of 5 artificial denture tooth materials. Volumetric wear was determined for Dentsply Trublend SLM, Dentsply IPN, Vita Vitapan, Ivoclar Orthotyp and Ivoclar Orthosit denture teeth. Scanning electron microscopy was also done to assess the textural character of the wear facets of each denture tooth sample. The lowest volume loss was observed for Trublend SLM followed by IPN, Orthotyp, Vitapan and Orthosit. Textural assessment of the materials was consistent with the objective wear data.
Fault Wear by Damage Evolution During Steady-State Slip
NASA Astrophysics Data System (ADS)
Lyakhovsky, Vladimir; Sagy, Amir; Boneh, Yuval; Reches, Ze'ev
2014-11-01
Slip along faults generates wear products such as gouge layers and cataclasite zones that range in thickness from sub-millimeter to tens of meters. The properties of these zones apparently control fault strength and slip stability. Here we present a new model of wear in a three-body configuration that utilizes the damage rheology approach and considers the process as a microfracturing or damage front propagating from the gouge zone into the solid rock. The derivations for steady-state conditions lead to a scaling relation for the damage front velocity considered as the wear-rate. The model predicts that the wear-rate is a function of the shear-stress and may vanish when the shear-stress drops below the microfracturing strength of the fault host rock. The simulated results successfully fit the measured friction and wear during shear experiments along faults made of carbonate and tonalite. The model is also valid for relatively large confining pressures, small damage-induced change of the bulk modulus and significant degradation of the shear modulus, which are assumed for seismogenic zones of earthquake faults. The presented formulation indicates that wear dynamics in brittle materials in general and in natural faults in particular can be understood by the concept of a "propagating damage front" and the evolution of a third-body layer.
Effect of tooth profile modification on wear in internal gears
NASA Astrophysics Data System (ADS)
Tunalioglu, M. S.; Tuc, B.
2018-05-01
Internal gears are often used in the automotive industry when two gears are required to rotate in the same direction. Tooth shapes, slippage speeds at the beginning and end of meshing are different according to the external gears. Manufacturing of internal gears is more difficult than external gears. Thus, it is necessary to determine the working conditions and wear behavior of internal gears carefully. The profile modification method in terms of strength and surface tension of the gear mechanism are performed in order to increase the load-carrying capability. In this study, profile modification method was performed in the internal gears to reduce the wear on the teeth. For this purpose, the wear of the internal gears was theoretically investigated by adapting the Archard wear equation to the internal gears. Closed circuit power circulation system was designed and manufactured to experimentally investigate the wear in internal gears. With this system, wear tests of gears made of St 50 material without profile modification and different profile modifications were made and the results were compared. Experimental study was performed in the same loading and cycle time conditions to validate the theoretical results and it was seen that the results are compatible. According to the experimental results, it is seen that in the internal gears, when profile modification done the wear is decreased in the teeth tip region.
Interaction of sulfuric acid corrosion and mechanical wear of iron
NASA Technical Reports Server (NTRS)
Rengstorff, G. W. P.; Miyoshi, K.; Buckley, D. H.
1986-01-01
Friction and wear experiment were conducted with elemental iron sliding on aluminum oxide in aerated sulfuric acid at concentrations ranging from very dilute (0.00007 N; i.e., 4 ppm) to very concentrated (96 percent acid). Load and reciprocating sliding speed were kept constant. With the most dilute acid concentration of 0.00007 to 0.0002 N, a complex corrosion product formed that was friable and often increased friction and wear. At slightly higher concentrations of 0.001 N, metal losses were essentially by wear alone. Because no buildup of corrosion products occurred, this acid concentration became the standard from which to separate metal loss from direct corrosion and mechanical wear losses. When the acid concentration was increased to 5 percent (1 N), the well-established high corrosion rate of iron in sulfuric acid strongly dominated the total wear loss. This strong corrosion increased to 30 percent acid and decreased somewhat to 50 percent acid in accordance with expectations. However, the low corrosion of iron expected at acid concentrations of 65 to 96 percent was not observed in the wear area. It was apparent that the normal passivating film was being worn away and a galvanic cell established that rapidly attacked the wear area. Under the conditions where direct corrosion losses were highest, the coefficient of friction was the lowest.
Interaction of sulfuric acid corrosion and mechanical wear of iron
NASA Technical Reports Server (NTRS)
Rengstorff, G. W. P.; Miyoshi, K.; Buckley, D. H.
1984-01-01
Friction and wear experiments were conducted with elemental iron sliding on aluminum oxide in aerated sulfuric acid at concentrations ranging from very dilute (0.00007 N; i.e., 4 ppm) to very concentrated (96 percent acid). Load and reciprocating sliding speed were kept constant. With the most dilute acid concentration of 0.00007 to 0.0002 N, a complex corrosion product formed that was friable and often increased friction and wear. At slightly higher concentrations of 0.001 N, metal losses were essentially by wear alone. Because no buildup of corrosion products occurred, this acid concentration became the standard from which to separate metal loss from direct corrosion and mechanical wear losses. When the acid concentration was increased to 5 percent (1 N), the well-established high corrosion rate of iron in sulfuric acid strongly dominated the total wear loss. This strong corrosion increased to 30 percent acid and decreased somewhat to 50 percent acid in accordance with expectations. However, the low corrosion of iron expected at acid concentrations of 65 to 96 percent was not observed in the wear area. It was apparent that the normal passivating film was being worn away and a galvanic cell established that rapidly attacked the wear area. Under the conditions where direct corrosion losses were highest, the coefficient of friction was the lowest.
Fissure sealant materials: Wear resistance of flowable composite resins
Asefi, Sohrab; Eskandarion, Solmaz; Hamidiaval, Shadi
2016-01-01
Background. Wear resistance of pit and fissure sealant materials can influence their retention. Wear characteristics of sealant materials may determine scheduling of check-up visits. The aim of this study was to compare wear resistance of two flowable composite resins with that of posterior composite resin materials. Methods. Thirty-five disk-shaped specimens were prepared in 5 groups, including two flowable composite resins (Estelite Flow Quick and Estelite Flow Quick High Flow), Filtek P90 and Filtek P60 and Tetric N-Ceram. The disk-shaped samples were prepared in 25-mm diameter by packing them into a two-piece aluminum mold and then light-cured. All the specimens were polished for 1minute using 600-grit sand paper. The samples were stored in distilled water at room temperature for 1 week and then worn by two-body abrasion test using "pin-on-disk" method (with distilled water under a 15-Nload at 0.05 m/s, for a distance of 100 meter with Steatite ceramic balls antagonists). A Profilometer was used for evaluating the surface wear. Data were analyzed with the one-way ANOVA. Results. Estelite Flow Quick exhibited 2708.9 ± 578.1 μm2 and Estelite Flow Quick High Flow exhibited 3206 ± 2445.1 μm2of wear but there were no significant differences between the groups. They demonstrated similar wear properties. Conclusion. Estelite flowable composite resins have wear resistance similar to nano- and micro-filled and micro-hybrid composite resins. Therefore, they can be recommended as pit and fissure sealant materials in the posterior region with appropriate mechanical characteristics. PMID:27651887
Fissure sealant materials: Wear resistance of flowable composite resins.
Asefi, Sohrab; Eskandarion, Solmaz; Hamidiaval, Shadi
2016-01-01
Background. Wear resistance of pit and fissure sealant materials can influence their retention. Wear characteristics of sealant materials may determine scheduling of check-up visits. The aim of this study was to compare wear resistance of two flowable composite resins with that of posterior composite resin materials. Methods. Thirty-five disk-shaped specimens were prepared in 5 groups, including two flowable composite resins (Estelite Flow Quick and Estelite Flow Quick High Flow), Filtek P90 and Filtek P60 and Tetric N-Ceram. The disk-shaped samples were prepared in 25-mm diameter by packing them into a two-piece aluminum mold and then light-cured. All the specimens were polished for 1minute using 600-grit sand paper. The samples were stored in distilled water at room temperature for 1 week and then worn by two-body abrasion test using "pin-on-disk" method (with distilled water under a 15-Nload at 0.05 m/s, for a distance of 100 meter with Steatite ceramic balls antagonists). A Profilometer was used for evaluating the surface wear. Data were analyzed with the one-way ANOVA. Results. Estelite Flow Quick exhibited 2708.9 ± 578.1 μm(2) and Estelite Flow Quick High Flow exhibited 3206 ± 2445.1 μm(2)of wear but there were no significant differences between the groups. They demonstrated similar wear properties. Conclusion. Estelite flowable composite resins have wear resistance similar to nano- and micro-filled and micro-hybrid composite resins. Therefore, they can be recommended as pit and fissure sealant materials in the posterior region with appropriate mechanical characteristics.
Wear properties of dental ceramics and porcelains compared with human enamel.
D'Arcangelo, Camillo; Vanini, Lorenzo; Rondoni, Giuseppe D; De Angelis, Francesco
2016-03-01
Contemporary pressable and computer-aided design/manufacturing (CAD/CAM) ceramics exhibit good mechanical and esthetic properties. Their wear resistance compared with human enamel and traditional gold based alloys needs to be better investigated. The purpose of this in vitro study was to compare the 2-body wear resistance of human enamel, gold alloy, and 5 different dental ceramics, including a recently introduced zirconia-reinforced lithium silicate ceramic (Celtra Duo). Cylindrical specimens were fabricated from a Type III gold alloy (Aurocast8), 2 hot pressed ceramics (Imagine PressX, IPS e.max Press), 2 CAD/CAM ceramics (IPS e.max CAD, Celtra Duo), and a CAD/CAM feldspathic porcelain (Vitablocs Mark II) (n=10). Celtra Duo was tested both soon after grinding and after a subsequent glaze firing cycle. Ten flat human enamel specimens were used as the control group. All specimens were subjected to a 2-body wear test in a dual axis mastication simulator for 120000 loading cycles against yttria stabilized tetragonal zirconia polycrystal cusps. The wear resistance was analyzed by measuring the vertical substance loss (mm) and the volume loss (mm(3)). Antagonist wear (mm) was also recorded. Data were statistically analyzed with 1-way ANOVA tests (α=.05). The wear depth (0.223 mm) of gold alloy was the closest to that of human enamel (0.217 mm), with no significant difference (P>.05). The greatest wear was recorded on the milled Celtra Duo (wear depth=0.320 mm), which appeared significantly less wear resistant than gold alloy or human enamel (P<.05). The milled and not glazed Celtra Duo showed a small but significantly increased wear depth compared with Aurocast8 and human enamel. Wear depth and volumetric loss for the glaze-fired Celtra Duo and for the other tested ceramics did not statistically differ in comparison with the human enamel. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Leone, José Pablo; Leone, Julieta; Vallejo, Carlos Teodoro; Pérez, Juan Eduardo; Romero, Alberto Omar; Machiavelli, Mario Raul; Romero Acuña, Luis; Domínguez, María Ester; Langui, Mario; Fasce, Hebe Margot; Leone, Bernardo Amadeo; Ortiz, Eduardo; Iturbe, Julián; Zwenger, Ariel Osvaldo
2014-01-01
Neoadjuvant chemotherapy (NAC) allows direct evaluation of the tumor's sensitivity to therapy, eradication of micrometastatic disease and the possibility of performing breast conserving surgery. The aim of this study was to describe long-term results of NAC in stage III breast cancer patients. We evaluated 126 patients that participated in a phase II randomized trial of neoadjuvant FAC compared with CMF. Chemotherapy was administered for three cycles prior to definitive surgery and radiotherapy, and then for six cycles as adjuvant. Median follow-up was 4.5 years (range 0.2-16.4). Objective response rate (OR) was similar in both groups (61 % for FAC, 66 % for CMF, P = NS). There were no differences in median disease free survival (DFS) or overall survival (OS) (5.1 vs 3.3 years and 6.7 vs 6.3 years for FAC and CMF, respectively). After 16 years of follow-up, 53 patients are still alive. Multivariate analysis showed that the number of pathologically involved lymph nodes (pLN) was the only factor associated with both, DFS and OS (P = 0.0003 and P = 0.0005, respectively). Both regimens were well tolerated, CMF had higher incidence of grade 3-4 leukopenia, thrombocytopenia, and stomatitis, whereas alopecia was more common in FAC. To the best of our knowledge, this is the first study to report long-term outcomes of FAC and CMF in the neoadjuvant setting. Within the sensitivity of our study, both regimens showed similar OR, long-term toxicity, DFS, and OS rate at 16 years. After 5 years, the hazard of death seems to decline. The prolonged follow-up of this study provides a unique opportunity to evaluate factors that predict long-term outcomes. After 16 years of follow-up, the number of pLN remains the most powerful predictor of survival.
Lievens, Christopher W; Connor, Charles G; Murphy, Heather
2003-10-01
The current study evaluates the response of the ocular surface to extended contact lens wear by comparing a new silicone hydrogel lens to an ACUVUE 2 lens. Twenty subjects with an average age of 28 years were randomly assigned to a fitting with ACUVUE 2 or PureVision lenses. Ocular surface assessment by impression cytology was performed at baseline and for the 6 months after initiation of lens wear. Although goblet cell density significantly increased with wear time, no statistically significant difference was observed between the contact lens groups. The average baseline goblet cell percentages were as follows: ACUVUE 2 group, 1.44; PureVision group, 1.11. The 6-month averages were as follows: ACUVUE 2 group, 3.16; PureVision group, 2.22. It appears that silicone hydrogel lenses may be slightly less irritating to the ocular surface than lenses not containing silicone. This could be a promising indicator for successful 30-day continuous wear.
The effect of casein phosphopeptide-amorphous calcium phosphate on erosive dentine wear.
Ranjitkar, S; Narayana, T; Kaidonis, J A; Hughes, T E; Richards, L C; Townsend, G C
2009-06-01
Erosive tooth wear is a growing concern in clinical dentistry. Our aims were to assess the effect of Tooth Mousse (TM) in managing erosive dentine wear in vitro. Opposing enamel and dentine specimens from 36 third molar teeth were worn under a load of 100 N for 75 000 cycles in electromechanical tooth wear machines. In experiment 1, TM was applied continuously at the wear interface and the mean dentine wear rate was compared with those of specimens subjected to continuous application of hydrochloric acid (HCl, pH 3.0) and deionized water (DW, pH 6.1) as lubricants. In experiment 2, specimens were subjected to TM application every 1600 cycles at both pH 3.0 and 6.1, and the mean dentine wear rates were compared with those of specimens worn with continuous application of HCl and DW lubricants. Dentine wear was reduced significantly with continuous application of TM compared with HCl and DW lubricants. Specimens prepared with continuous TM application displayed smooth wear facets, whereas more pronounced microwear details were observed with HCl and DW lubricants. Both remineralization and lubrication seem to contribute to reduction in dentine wear associated with TM application, although lubrication appears to have a more pronounced effect.
Type of motion and lubricant in wear simulation of polyethylene acetabular cup.
Saikko, V; Ahlroos, T
1999-01-01
The wear of ultra-high molecular weight polyethylene, the most commonly used bearing material in prosthetic joints, is often substantial, posing a significant clinical problem. For a long time, there has been a need for simple but still realistic wear test devices for prosthetic joint materials. The wear factors produced by earlier reciprocating and unidirectionally rotating wear test devices for polyethylene are typically two orders of magnitude too low, both in water and in serum lubrication. Wear is negligible even under multidirectional motion in water. A twelve-station, circularly translating pin-on-disc (CTPOD) device and a modification of the established biaxial rocking motion hip joint simulator were built. With these simple and inexpensive devices, and with the established three-axis hip joint simulator, realistic wear simulation was achieved. This was due to serum lubrication and to the fact that the direction of sliding constantly changed relative to the polyethylene specimen. The type and magnitude of load was found to be less important. The CTPOD tests showed that the subsurface brittle region, which results from gamma irradiation sterilization of polyethylene in air, has poor wear resistance. Phospholipid and soy protein lubrication resulted in unrealistic wear. The introduction of devices like CTPOD may boost wear studies, rendering them feasible without heavy investment.
Investigation of wear land and rate of locally made HSS cutting tool
NASA Astrophysics Data System (ADS)
Afolalu, S. A.; Abioye, A. A.; Dirisu, J. O.; Okokpujie, I. P.; Ajayi, O. O.; Adetunji, O. R.
2018-04-01
Production technology and machining are inseparable with cutting operation playing important roles. Investigation of wear land and rate of cutting tool developed locally (C=0.56%) with an HSS cutting tool (C=0.65%) as a control was carried out. Wear rate test was carried out using Rotopol -V and Impact tester. The samples (12) of locally made cutting tools and one (1) sample of a control HSS cutting tool were weighed to get the initial weight and grit was fixed at a point for the sample to revolve at a specific time of 10 mins interval. Approach of macro transfer particles that involved mechanism of abrasion and adhesion which was termed as mechanical wear to handle abrasion adhesion processes was used in developing equation for growth wear at flank. It was observed from the wear test that best minimum wear rate of 1.09 × 10-8 and 2.053 × 10-8 for the tools developed and control were measured. MATLAB was used to simulate the wear land and rate under different conditions. Validated results of both the experimental and modeling showed that cutting speed has effect on wear rate while cutting time has predicted measure on wear land. Both experimental and modeling result showed best performances of tools developed over the control.
Comparing Sliding-Wear Characteristics of the Electro-Pressure Sintered and Wrought Cobalt
NASA Astrophysics Data System (ADS)
Lee, J. E.; Kim, Y. S.; Kim, T. W.
Dry sliding wear tests of hot-pressure sintered and wrought cobalt were carried out to compare their wear characteristics. Cobalt powders with average size of 1.5µm were electro-pressure sintered to make sintered-cobalt disk wear specimens. A vacuum-induction melted cobalt ingot was hot-rolled at 800°C to a plate, from which wrought-cobalt disk specimens were machined. The specimens were heat treated at various temperatures to vary grain size and phase fraction. Wear tests of the cobalt specimens were carried out using a pin-on-disk wear tester against a glass (83% SiO2) bead at 100N with the constant sliding speed and distance of 0.36m/s and 600m, respectively. Worn surfaces, their cross sections, and wear debris were examined by an SEM. The wear of the cobalt was found to be strongly influenced by the strain-induced phase transformation of ɛ-Co (hcp) to α-Co (fcc). The sintered cobalt had smaller uniform grain size and showed higher wear rate than the wrought cobalt. The higher wear rate of the sintered cobalt was explained by the more active deformation-induced phase transformation than in the wrought cobalt with larger irregular grains.
Wear studies of all UHMWPE couples under various bio-tribological conditions.
Joyce, T J; Unsworth, A
2004-01-01
Wear tests were undertaken in which ultra high molecular weight polyethylene (UHMWPE) was rubbed against itself. Tests primarily employed a pin-on-plate wear test machine, with distilled water, Ringer solution and dilute bovine serum being used as the lubricants. Loads of 10N and 40N were employed, and some test pins had a rotational motion added. In all cases wear was high, with mean wear factors of up to 91 10 -6 mm3/Nm being measured, but the addition of rotation reduced the amount of material worn from the test plates. In the presence of bovine serum and under reciprocation only, pin wear was relatively low. With bovine serum as the lubricant, total mean wear factors for the UHMWPE couples were calculated to be in the range of 35 to 58 10-6mm3/Nm. Therefore the pin-on-plate tests showed that the choice of lubricant as well as the motion applied to the test pin had a significant influence on the wear volumes measured. A two-piece UHMWPE 'prosthesis' with matching hemispherical faces was fabricated and tested on a finger simulator. Distilled water was used as the lubricant and wear factors were found to be greater for the metacarpal component, 21 10 -6mm3/Nm, than the phalangeal component, 3 10-6mm3/Nm, after ten million cycles of testing. This result paralleled the greater wear seen by the plate than by the pin in the pin-on-plate tests under reciprocating motion. (Journal of Applied Biomaterials & Biomechanics 2004; 2: 29-34).
Sun, Yue; Ban, Bhupal; Bradbury, Andrew; ...
2016-08-29
The development of antibodies to low molecular weight haptens remains challenging due to both the low immunogenicity of many haptens and the cross-reactivity of the protein carriers used to generate the immune response. Recombinant antibodies and novel display technologies have greatly advanced antibody development; however, new techniques are still required to select rare hapten-specific antibodies from large recombinant libraries. In the present study, we used a combination of phage and yeast display to screen an immune antibody library (size, 4.4 × 10 6 ) against hapten markers for petroleum contamination (phenanthrene and methylphenanthrenes). Selection via phage display was used firstmore » to enrich the library between 20- and 100- fold for clones that bound to phenanthrene-protein conjugates. The enriched libraries were subsequently transferred to a yeast display system and a newly developed competitive FACS procedure was employed to select rare hapten-specific clones. Competitive FACS increased the frequency of hapten-specific scFvs in our yeast-displayed scFvs from 0.025 to 0.005% in the original library to between 13 and 35% in selected pools. The presence of hapten-specific scFvs was confirmed by competitive ELISA using periplasmic protein. Three distinct antibody clones that recognize phenanthrene and methylphenanthrenes were selected, and their distinctive binding properties were characterized. To our knowledge, these are first antibodies that can distinguish between methylated (petrogenic) versus unmethylated (pyrogenic) phenanthrenes; such antibodies will be useful in detecting the sources of environmental contamination. Furthermore, this selection method could be generally adopted in the selection of other hapten-specific recombinant antibodies.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sun, Yue; Ban, Bhupal; Bradbury, Andrew
The development of antibodies to low molecular weight haptens remains challenging due to both the low immunogenicity of many haptens and the cross-reactivity of the protein carriers used to generate the immune response. Recombinant antibodies and novel display technologies have greatly advanced antibody development; however, new techniques are still required to select rare hapten-specific antibodies from large recombinant libraries. In the present study, we used a combination of phage and yeast display to screen an immune antibody library (size, 4.4 × 10 6 ) against hapten markers for petroleum contamination (phenanthrene and methylphenanthrenes). Selection via phage display was used firstmore » to enrich the library between 20- and 100- fold for clones that bound to phenanthrene-protein conjugates. The enriched libraries were subsequently transferred to a yeast display system and a newly developed competitive FACS procedure was employed to select rare hapten-specific clones. Competitive FACS increased the frequency of hapten-specific scFvs in our yeast-displayed scFvs from 0.025 to 0.005% in the original library to between 13 and 35% in selected pools. The presence of hapten-specific scFvs was confirmed by competitive ELISA using periplasmic protein. Three distinct antibody clones that recognize phenanthrene and methylphenanthrenes were selected, and their distinctive binding properties were characterized. To our knowledge, these are first antibodies that can distinguish between methylated (petrogenic) versus unmethylated (pyrogenic) phenanthrenes; such antibodies will be useful in detecting the sources of environmental contamination. Furthermore, this selection method could be generally adopted in the selection of other hapten-specific recombinant antibodies.« less
Effect of carbon content on friction and wear of cast irons
NASA Technical Reports Server (NTRS)
Buckley, D. H.
1977-01-01
Friction and wear experiments were conducted with cast irons and wrought steels containing various amounts of carbon in the alloy structure in contact with 52100 steel. Gray cast irons were found to exhibit lower friction and wear characteristics than white cast irons. Further, gray cast iron wear was more sensitive to carbon content than was white. Wear with gray cast iron was linearly related to load, and friction was found to be sensitive to relative humidity and carbon content. The form, in which the carbon is present in the alloy, is more important, as the carbon content and no strong relationship seems to exist between hardness of these ferrous alloys and wear.
Investigation on the Tribological Behavior and Wear Mechanism of Five Different Veneering Porcelains
Min, Jie; Zhang, Qianqian; Qiu, Xiaoli; Zhu, Minhao; Yu, Haiyang; Gao, Shanshan
2015-01-01
Objectives The primary aim of this research was to investigate the wear behavior and wear mechanism of five different veneering porcelains. Methods Five kinds of veneering porcelains were selected in this research. The surface microhardness of all the samples was measured with a microhardness tester. Wear tests were performed on a ball-on-flat PLINT fretting wear machine, with lubrication of artificial saliva at 37°C. The friction coefficients were recorded by the testing system. The microstructure features, wear volume, and damage morphologies were recorded and analyzed with a confocal laser scanning microscope and a scanning electron microscope. The wear mechanism was then elucidated. Results The friction coefficients of the five veneering porcelains differ significantly. No significant correlation between hardness and wear volume was found for these veneering porcelains. Under lubrication of artificial saliva, the porcelain with higher leucite crystal content exhibited greater wear resistance. Additionally, leucite crystal size and distribution in glass matrix influenced wear behavior. The wear mechanisms for these porcelains were similar: abrasive wear dominates the early stage, whereas delamination was the main damage mode at the later stage. Furthermore, delamination was more prominent for porcelains with larger crystal sizes. Significance Wear compatibility between porcelain and natural teeth is important for dental restorative materials. Investigation on crystal content, size, and distribution in glass matrix can provide insight for the selection of dental porcelains in clinical settings. PMID:26368532
Radiographic methods of wear analysis in total hip arthroplasty.
Rahman, Luthfur; Cobb, Justin; Muirhead-Allwood, Sarah
2012-12-01
Polyethylene wear is an important factor in failure of total hip arthroplasty (THA). With increasing numbers of THAs being performed worldwide, particularly in younger patients, the burden of failure and revision arthroplasty is increasing, as well, along with associated costs and workload. Various radiographic methods of measuring polyethylene wear have been developed to assist in deciding when to monitor patients more closely and when to consider revision surgery. Radiographic methods that have been developed to measure polyethylene wear include manual and computer-assisted plain radiography, two- and three-dimensional techniques, and radiostereometric analysis. Some of these methods are important in both clinical and research settings. CT has the potential to provide additional information on component orientation and enables assessment of periprosthetic osteolysis, which is an important consequence of polyethylene wear.
Nutritional status, tooth wear and quality of life in Brazilian schoolchildren.
Andrade, Francisco Juliherme Pires de; Sales-Peres, André de Carvalho; Moura-Grec, Patricia Garcia de; Mapengo, Marta Artemisa Abel; Sales-Peres, Arsenio; Sales-Peres, Sílvia Helena de Carvalho
2016-06-01
To evaluate the correlation among nutritional status, tooth wear and quality of life in Brazilian schoolchildren. The study followed a cross-sectional design. Nutritional status was measured via anthropometry using BMI and tooth wear was measured using the Dental Wear Index; both these assessments were carried out by a trained recorder according to standard criteria. A modified version of the Child Oral Impacts on Daily Performances was used to assess quality of life. City of Bauru, in Brazil. A cluster sample of 396 schoolchildren (194 boys and 202 girls) aged 7-10 years. The anthropometric assessment showed similar situations for both sexes regarding underweight (31·40 % in boys and 30·20 % in girls) and overweight/obesity (33·96 % in boys and 33·17 % in girls). The underweight children showed a greater severity of tooth wear in the primary teeth (OR=0·72; CI 0·36, 1·42), although in the permanent dentition the obese children had a greater severity of tooth wear (OR=1·42; 95 % CI 0·31, 6·55). The tooth wear was correlated with age for both dentitions. Tooth wear in the primary and permanent dentition may be related to nutritional status. Tooth wear and obesity did not have a significant impact on the schoolchildren's perception of quality of life.
Increased conformity offers diminishing returns for reducing total knee replacement wear.
Fregly, Benjamin J; Marquez-Barrientos, Carlos; Banks, Scott A; DesJardins, John D
2010-02-01
Wear remains a significant problem limiting the lifespan of total knee replacements (TKRs). Though increased conformity between TKR components has the potential to decrease wear, the optimal amount and planes of conformity have not been investigated. Furthermore, differing conformities in the medial and lateral compartments may provide designers the opportunity to address both wear and kinematic design goals simultaneously. This study used a computational model of a Stanmore knee simulator machine and a previously validated wear model to investigate this issue for simulated gait. TKR geometries with different amounts and planes of conformity on the medial and lateral sides were created and tested in two phases. The first phase utilized a wide range of sagittal and coronal conformity combinations to blanket a physically realistic design space. The second phase performed a focused investigation of the conformity conditions from the first phase to which predicted wear volume was sensitive. For the first phase, sagittal but not coronal conformity was found to have a significant effect on predicted wear volume. For the second phase, increased sagittal conformity was found to decrease predicted wear volume in a nonlinear fashion, with reductions gradually diminishing as conformity increased. These results suggest that TKR geometric design efforts aimed at minimizing wear should focus on sagittal rather than coronal conformity and that at least moderate sagittal conformity is desirable in both compartments.
Two-body and three-body wear of glass ionomer cements.
Kunzelmann, K H; Bürkle, V; Bauer, C
2003-11-01
Glass ionomer cements (GIC) have been modified in an attempt to improve their mechanical properties. The objective of the present paper was to compare the two-body and three-body wear of four modified GIC. The tested materials were Fuji IX (GC Corporation), Hi-Fi (Shofu) and Ketac Molar Aplicap (3M/ESPE). The cermet cement Ketac Silver Maxicap (3M/ESPE) was used as reference material. Two-body wear tests were carried out in the computer controlled 'artificial mouth' of the Munich Dental School, three-body wear was tested with the ACTA wear machine. The resulting average two-body wear rates (in microm) were: Fuji IX 327 (SD +/- 82) < Ketac Molar 379 (SD +/- 94) < Hi-Fi 376 (SD +/- 90) < Ketac silver 449 (SD +/- 127). The differences between the materials were significant (P < 0.05, ANOVA, modified LSD-test) with the exception of Ketac Molar and Hi-Fi. The average three-body wear rates (in microm) were: Hi-Fi 30 (SD +/- 10) < Ketac Molar +/- 42 (SD +/- 12) < Fuji IX 49 (SD +/- 14) < Ketac silver 73 (SD +/- 23). The difference between Ketac silver and the three other materials was significant (P < 0.05, ANOVA, modified LSD-test). No significant difference was calculated between Hi-Fi, Ketac Molar and Fuji IX. As Ketac Molar, Hi-Fi and Fuji IX show better wear resistance compared to Ketac silver both in occlusal-contact and contact-free areas, it may be assumed that the wear resistance of a glass ionomer cement may be improved more by changing the powder: liquid ratio than by incorporating silver particles into the glass powder.
46 CFR 185.508 - Wearing of life jackets.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 7 2011-10-01 2011-10-01 false Wearing of life jackets. 185.508 Section 185.508... TONS) OPERATIONS Preparations for Emergencies § 185.508 Wearing of life jackets. (a) The master of a vessel shall require passengers to don life jackets when possible hazardous conditions exist, including...
46 CFR 185.508 - Wearing of life jackets.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false Wearing of life jackets. 185.508 Section 185.508... TONS) OPERATIONS Preparations for Emergencies § 185.508 Wearing of life jackets. (a) The master of a vessel shall require passengers to don life jackets when possible hazardous conditions exist, including...
46 CFR 185.508 - Wearing of life jackets.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 7 2012-10-01 2012-10-01 false Wearing of life jackets. 185.508 Section 185.508... TONS) OPERATIONS Preparations for Emergencies § 185.508 Wearing of life jackets. (a) The master of a vessel shall require passengers to don life jackets when possible hazardous conditions exist, including...
46 CFR 185.508 - Wearing of life jackets.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 7 2014-10-01 2014-10-01 false Wearing of life jackets. 185.508 Section 185.508... TONS) OPERATIONS Preparations for Emergencies § 185.508 Wearing of life jackets. (a) The master of a vessel shall require passengers to don life jackets when possible hazardous conditions exist, including...
46 CFR 185.508 - Wearing of life jackets.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 7 2013-10-01 2013-10-01 false Wearing of life jackets. 185.508 Section 185.508... TONS) OPERATIONS Preparations for Emergencies § 185.508 Wearing of life jackets. (a) The master of a vessel shall require passengers to don life jackets when possible hazardous conditions exist, including...
A Multidirectional Tribo-System: Wear of UHMWPE under Sliding, Rolling, and Rotation
NASA Astrophysics Data System (ADS)
Patten, Elias Wolfgang
Total knee replacements (TKR) have become a successful surgical procedure for addressing end-stage osteoarthritis, with ultra-high molecular weight polyethylene and cobalt chrome alloy (UHMWPE/Co-Cr) serving as the bearing materials of choice for decades. However, more than 10% of TKRs fail and require revision surgery. The predominant challenge with UHMWPE is the particulate debris generated through wear-mediated processes; wear debris from the UHMWPE tibial bearing surface leading to loosening is still the main cause for post-fifth-year revisions. UHMWPE wear in hip arthroplasty has been linked to microstructural evolution at the surface from multidirectional sliding in the hip joint but little is known about how the microstructure responds to clinically relevant sliding conditions in the knee. This is likely because wear tests are typically performed under basic motion parameters with simplified geometry (pin-on-disk tests) while the knee has more complex kinematics: it is neither a ball-and-socket joint nor a simple hinge joint, but has 2D sliding, rolling/slip motion, and rotation. There is also disagreement over how to best quantify cross-shear and how to model how much wear it will cause. A custom multidirectional tribo-system was used to investigate the individual and combined effects of the different motions in TKR: 2D sliding, rolling, and rotation, for a total of eight separate kinematic conditions. The trends in wear rates and wear factors for these different motions were compared with many different definitions for magnitudes and ratios of cross-shear. Additionally, the wear surfaces were examined for wear mechanism and the microstructural changes in lamellae orientation for the different motions were analyzed. To mimic the tribological conditions of a condyle in a TKR, polished Co-Cr spheres were articulated against flat, smooth UHMWPE disks with physiologically relevant loading, speed, and lubrication conditions. The motion parameters were selected
Sex differences in Hadza dental wear patterns : a preliminary report.
Berbesque, J Colette; Marlowe, Frank W; Pawn, Ian; Thompson, Peter; Johnson, Guy; Mabulla, Audax
2012-09-01
Among hunter-gatherers, the sharing of male and female foods is often assumed to result in virtually the same diet for males and females. Although food sharing is widespread among the hunting and gathering Hadza of Tanzania, women were observed eating significantly more tubers than men. This study investigates the relationship between patterns of dental wear, diet, and extramasticatory use of teeth among the Hadza. Casts of the upper dentitions were made from molds taken from 126 adults and scored according to the Murphy dental attrition scoring system. Females had significantly greater anterior occlusal wear than males when we controlled for age. Males exhibited greater asymmetry in wear, with greater wear on the left side in canines, first premolars, and first molars. We suggest that these sex differences in wear patterns reflect the differences seen in the diet, as well as in the use of teeth as tools.
A study on die wear model of warm and hot forgings
NASA Astrophysics Data System (ADS)
Kang, J. H.; Park, I. W.; Jae, J. S.; Kang, S. S.
1998-05-01
Factors influencing service lives of tools in warm and hot forging processes are wear, mechanical fatigue, plastic deformation and thermal fatigue, etc. Wear is the predominant factor for tool failure among these. To predict tool life by wear, Archard's model where hardness is considered as constant or function of temperature is generally applied. Usually hardness of die is a function of not only temperature but operating time of die. To consider softening of die by repeated operation it is necessary to express hardness of die by a function of temperature and time. In this study wear coefficients were measured for various temperatures and heat treatment for H13 tool steel. Also by experiment of reheating of die, die softening curves were obtained. From experimental results, relationships between tempering parameters and hardness were established to investigate effects of hardness decrease by the effect of temperatures and time. Finally modified Archard's wear model in which hardness is considered to be a function of main tempering curve was proposed. And finite element analyses were conducted by adopting suggested wear model. By comparisons of simulations and real profiles of worn die, proposed wear model was verified.
A WEAR MODEL FOR DIESEL ENGINE EXHAUST VALVES
DOE Office of Scientific and Technical Information (OSTI.GOV)
Blau, Peter Julian
2009-11-01
The work summarized here comprises the concluding effort of a multi-year project, funded by the U.S. Department of Energy, Office of Vehicle Technologies. It supports the development of a better understanding of advanced diesel engine designs in which enhanced power density, energy efficiency, and emissions control place increasing demands upon the durability of engine materials. Many kinds of metallic alloys are used in engines depending on the operating stresses, temperatures, and chemical environments. Exhaust valves, for example, are subjected to high temperatures and repetitive surface contacts that place demands on durability and frictional characteristics of the materials. Valves must continuemore » to seal the combustion chamber properly for thousands of hours of cyclic engine operation and under varying operating conditions. It was the focus of this effort to understand the wear processes in the valve-seat area and to develop a model for the surface deformation and wear of that important interface. An annotated bibliography is provided to illustrate efforts to understand valve wear and to investigate the factors of engine operation that affect its severity and physical manifestation. The project for which this modeling effort was the final task, involved construction of a high-temperature repetitive impact test system as well as basic tribology studies of the combined processes of mechanical wear plus oxidation at elevated temperatures. Several publications resulted from this work, and are cited in this report. The materials selected for the experimental work were high-performance alloys based on nickel and cobalt. In some cases, engine-tested exhaust valves were made available for wear analysis and to ensure that the modes of surface damage produced in experiments were simulative of service. New, production-grade exhaust valves were also used to prepare test specimens for experimental work along with the other alloy samples. Wear analysis of valves and
Esclassan, R; Grimoud, A M; Ruas, M P; Donat, R; Sevin, A; Astie, F; Lucas, S; Crubezy, E
2009-03-01
The aims of the present work were to determine the frequency and distribution of caries and tooth wear on paired maxillae of a mediaeval sample from southwest France in which the sex of the remains had been established, and to make a relation with the diet of this population. The sample analysed consisted of the dental remains of 58 adult individuals (29 men and 29 women) excavated from the mediaeval cemetery of the archaeological site of Vilarnau d'Amont (southwest France). A total of 1395 teeth were examined. The frequency of ante-mortem tooth loss for the sample was 8.7% and the frequency of caries was 17.5%. The frequencies of carious lesions in adult men and women's dentition were 21.9% and 14.0%. The most frequent were occlusal (49.7% and 34.3%) and approximal caries (26.5% and 37.4%). Concerning tooth wear, all 58 individuals were affected by attrition (100%) and more than 90% of the teeth were concerned. Most of them showed the presence of dentin clusters. There was no significant difference between men and women for caries and tooth wear. These findings are similar to those of other studies on European populations of the same socio-economic status and confirm the predominance of tooth wear over carious lesions during this period. Both caries and tooth wear may be related to the regional diet of this rural population.
Tooth wear among patients suffering from mental disorders
Piccoli, Luca; Besharat, Laith Konstantinos; Cassetta, Michele; Migliau, Guido; Di Carlo, Stefano; Pompa, Giorgio
2014-01-01
Summary Aim Assess oral health, treatment needs and the correlation between tooth wear and medications in patients with psychiatric disease. Methodology 92 patients (40 male and 52 female) admitted in the Department of Neurology and Psychiatry of the Umberto I Hospital of Rome underwent an oral and dental clinical examination in accordance according to World Health Organization Basic Methods Criteria. One dentist performed all clinical examinations, training and calibration was carried out by an experienced clinical examiner. To measure the degree of inter-examiner agreement Kappa statistics was calculated. Level of tooth wear was assessed using the tooth wear classification of Johansson et al. Exact psychiatric pathology and medications of each patient were registrated. The Statistical Package for the Social Sciences (SPSS Inc., Chicago, Ill.) was used to analyze the data. A value of P < 0.05 was considered statistically significant. Results 34.78% of the sample regarding tooth wear demonstrated score 2. Men demonstrated 30% score 2, and 20% score 3 and 4 whereas female patients 38.46% score 2, 7.69% score 3 and none score 4. Conclusions Chronic exposure to neuroleptic drugs can cause phenomena of bruxism. There is a direct correlation between tooth wear, psychiatric disorders and administration of certain drugs. Poor oral hygiene and extensive unmet needs for dental treatment were widespread among psychiatric patients. PMID:25002918
Glenoid wear after shoulder hemiarthroplasty: quantitative radiographic analysis.
Parsons, I M; Millett, Peter J; Warner, Jon J P
2004-04-01
Symptomatic glenoid arthrosis may limit the long-term success of shoulder hemiarthroplasty in patients who are young and functionally demanding. The principal objective of the current study was to quantify glenoid wear after proximal humeral replacement in young, active subjects. Eight patients, ages 21 to 60 years (mean, 45 years), met inclusion criteria. The mean followup was 43 months. Functional scores for the cohort averaged 60% of age and gender-adjusted healthy subjects (range, 28%-84%). Glenohumeral joint space was measured on serial axillary radiographs using a Microscribe 3-DX digitizing device (measurement accuracy, 0.23 mm). Progressive glenoid wear was found in all eight patients. The mean decrease was 2 mm (range, 1.3-2.8 mm), a 68% decrease in glenohumeral joint space. Glenoid cartilage wear also was correlated with Constant and Murley scores. Patients with residual joint spaces less than 1 mm had a mean score of 50%, compared with a score of 71% for patients with joint spaces greater than 1 mm. There were no correlations between wear and mechanism of injury, duration of symptoms, and prior surgery. This study suggests that glenoid cartilage erosion can be expected routinely after humeral head replacement in young, active individuals, and that such wear may adversely affect function or necessitate conversion to total shoulder arthroplasty.
Modeling and Tool Wear in Routing of CFRP
DOE Office of Scientific and Technical Information (OSTI.GOV)
Iliescu, D.; Fernandez, A.; Gutierrez-Orrantia, M. E.
2011-01-17
This paper presents the prediction and evaluation of feed force in routing of carbon composite material. In order to extend tool life and improve quality of the machined surface, a better understanding of uncoated and coated tool behaviors is required. This work describes (1) the optimization of the geometry of multiple teeth tools minimizing the tool wear and the feed force, (2) the optimization of tool coating and (3) the development of a phenomenological model between the feed force, the routing parameters and the tool wear. The experimental results indicate that the feed rate, the cutting speed and the toolmore » wear are the most significant factors affecting the feed force. In the case of multiple teeth tools, a particular geometry with 14 teeth right helix right cut and 11 teeth left helix right cut gives the best results. A thick AlTiN coating or a diamond coating can dramatically improve the tool life while minimizing the axial force, roughness and delamination. A wear model has then been developed based on an abrasive behavior of the tool. The model links the feed rate to the tool geometry parameters (tool diameter), to the process parameters (feed rate, cutting speed and depth of cut) and to the wear. The model presented has been verified by experimental tests.« less
75 FR 39413 - Federal Acquisition Regulation; Federal Acquisition Circular 2005-44; Introduction
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-08
... Acquisition Council and the Defense Acquisition Regulations Council in this Federal Acquisition Circular (FAC) 2005-44. A companion document, the Small Entity Compliance Guide (SECG), follows this FAC. The FAC.... Please cite FAC 2005-44 and the FAR case number. Interested parties may also visit our Web site at http...
Coatings for wear and lubrication
NASA Technical Reports Server (NTRS)
Spalvins, T.
1978-01-01
Recent advances in the tribological uses of rf-sputtered and ion plated films of solid film lubricants (laminar solids, soft metals, organic polymers) and wear resistant refractory compounds (carbides, nitrides, silicides) are reviewed. The sputtering and ion plating potentials and the corresponding coatings formed were evaluated relative to the friction coefficient, wear endurance life and mechanical properties. The tribological and mechanical properties for each kind of film are discussed in terms of film adherence, coherence, density, grain size, morphology, internal stresses, thickness, and substrate conditions such as temperature, topography, chemistry and dc-biasing. The ion plated metallic films in addition to improved tribological properties also have better mechanical properties such as tensile strength and fatigue life.
A Computerized Wear Particle Atlas for Ferrogram and Filtergram Analyses
1998-01-01
A Computerised Wear Particle Atlas for Ferrogram and Filtergram Analyses Jian G. Ding Lubrosoft P/L P 0 Box 2368, Rowville Melbourne VIC 3178...Australia (61-3) 9759-9083 Abstract: A new computerised wear particle atlas has been developed for identification of solid particles and...differentiation of wear severity of lubricated equipment. This atlas contains 892 images of representative solid particles selected from thousands of filtergram
Zobi, Fabio
2009-11-16
A ligand parameter, IR(P)(L), is introduced in order to evaluate the effect that different monodentate and bidentate ligands have on the symmetric C[triple bond]O stretching frequency of octahedral d(6) fac-[Re(CO)(3)L(3)] complexes (L = mono- or bidentate ligand). The parameter is empirically derived by assuming that the electronic effect, or contribution, that any given ligand L will add to the fac-[ReCO(3)](+) core, in terms of the total observed energy of symmetric C[triple bond]O stretching frequency (nu(CO(obs))), is additive. The IR(P)(CO) (i.e., the IR(P) of carbon monoxide) is first defined as one-sixth that of the observed C[triple bond]O frequency (nu(CO(obs))) of [Re(CO)(6)](+). All subsequent IR(P)(L) parameters of fac-[Re(CO)(3)L(3)] complexes are derived from IR(P)(L) = (1)/(3)[nu(CO(obs)) - 3IR(P)(CO)]. The symmetric C[triple bond]O stretching frequency was selected for analysis by assuming that it alone describes the "average electronic environment" in the IR spectra of the complexes. The IR(P)(L) values for over 150 ligands are listed, and the validity of the model is tested against other octahedral d(6) fac-[M(CO)(3)L(3)] complexes (M = Mn, (99)Tc, and Ru) and cis-[Re(CO)(2)L(4)](+) species and by calculations at the density functional level of theory. The predicted symmetric C[triple bond]O stretching frequency (nu(CO(cal))) is given by nu(CO(cal)) = S(R)[ sum IR(P)(L)] + I(R), where S(R) and I(R) are constants that depend upon the metal, its oxidation state, and the number of CO ligands in its primary coordination sphere. A linear relationship between IR(P) values and the well-established ligand electrochemical parameter E(L) is found. From a purely thermodynamic point of view, it is suggested that ligands with high IR(P)(L) values should weaken the M-CO bond to a greater extent than ligands with low IR(P)(L) values. The significance of the results and the limitations of the model are discussed.
Yamamoto, Kengo; Masaoka, Toshinori; Manaka, Masakazu; Oonishi, Hironobu; Clarke, Ian; Shoji, Hiromu; Kawanabe, Keiichi; Imakiire, Atsuhiro
2004-04-01
We studied the micro-wear phenomena of unique, extensively cross-linked polyethylene cups (cross-linked with 1,000 kGy-irradiation) that had been used briefly in Japan. Two retrievals (at 15 years) came from the Japanese "SOM" hip system (implanted 1971-78). These were compared to a set of 0 kGy and 500-1,500 kGy cups run in our hip simulator. The polyethylene cups that had not been cross-linked had the greatest wear. The worn areas had a burnished appearance and were clearly separated from the unworn region by a distinct ridge-line. The worn areas had lost all machine tracks, showed a large amount of UHMWPE 'flow', and long PE fibrils. The associated surface rippling was degraded. These features were considered synonymous with severe polyethylene wear. In contrast, the worn areas in the very cross-linked cups had a visibly matte surface and no ridge-line. Micro-examination showed that the machine tracks were still present. Ripple formations were less obvious than in the cups that were not cross-linked, polyethylene surface fibrils were scarcer and all the fibrils were much smaller than in the cups that were not crosslinked. Our two retrieved cups and the simulator cups confirmed the greater wear-resistance of very cross-linked polyethylene. It should also be noted that the SOM cup design and processing were unique and differed greatly from that of modern polyethylene cups.
46 CFR 122.508 - Wearing of life jackets.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Wearing of life jackets. 122.508 Section 122.508... Preparations for Emergencies § 122.508 Wearing of life jackets. (a) The master of a vessel shall require passengers to don life jackets when possible hazardous conditions exist, including, but not limited to: (1...
46 CFR 122.508 - Wearing of life jackets.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Wearing of life jackets. 122.508 Section 122.508... Preparations for Emergencies § 122.508 Wearing of life jackets. (a) The master of a vessel shall require passengers to don life jackets when possible hazardous conditions exist, including, but not limited to: (1...
46 CFR 122.508 - Wearing of life jackets.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Wearing of life jackets. 122.508 Section 122.508... Preparations for Emergencies § 122.508 Wearing of life jackets. (a) The master of a vessel shall require passengers to don life jackets when possible hazardous conditions exist, including, but not limited to: (1...
46 CFR 122.508 - Wearing of life jackets.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Wearing of life jackets. 122.508 Section 122.508... Preparations for Emergencies § 122.508 Wearing of life jackets. (a) The master of a vessel shall require passengers to don life jackets when possible hazardous conditions exist, including, but not limited to: (1...
46 CFR 122.508 - Wearing of life jackets.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Wearing of life jackets. 122.508 Section 122.508... Preparations for Emergencies § 122.508 Wearing of life jackets. (a) The master of a vessel shall require passengers to don life jackets when possible hazardous conditions exist, including, but not limited to: (1...
Comparative abrasive wear resistance and surface analysis of dental resin-based materials
Nayyer, Maleeha; Zahid, Shahreen; Hassan, Syed Hammad; Mian, Salman Aziz; Mehmood, Sana; Khan, Haroon Ahmed; Kaleem, Muhammad; Zafar, Muhammad Sohail; Khan, Abdul Samad
2018-01-01
Objective: The objective of this study was to assess the surface properties (microhardness and wear resistance) of various composites and compomer materials. In addition, the methodologies used for assessing wear resistance were compared. Materials and Methods: This study was conducted using restorative material (Filtek Z250, Filtek Z350, QuiXfil, SureFil SDR, and Dyract XP) to assess wear resistance. A custom-made toothbrush simulator was employed for wear testing. Before and after wear resistance, structural, surface, and physical properties were assessed using various techniques. Results: Structural changes and mass loss were observed after treatment, whereas no significant difference in terms of microhardness was observed. The correlation between atomic force microscopy (AFM) and profilometer and between wear resistance and filler volume was highly significant. The correlation between wear resistance and microhardness were insignificant. Conclusions: The AFM presented higher precision compared to optical profilometers at a nanoscale level, but both methods can be used in tandem for a more detailed and precise roughness analysis. PMID:29657526
Accuracy and precision of estimating age of gray wolves by tooth wear
Gipson, P.S.; Ballard, W.B.; Nowak, R.M.; Mech, L.D.
2000-01-01
We evaluated the accuracy and precision of tooth wear for aging gray wolves (Canis lupus) from Alaska, Minnesota, and Ontario based on 47 known-age or known-minimum-age skulls. Estimates of age using tooth wear and a commercial cementum annuli-aging service were useful for wolves up to 14 years old. The precision of estimates from cementum annuli was greater than estimates from tooth wear, but tooth wear estimates are more applicable in the field. We tended to overestimate age by 1-2 years and occasionally by 3 or 4 years. The commercial service aged young wolves with cementum annuli to within ?? 1 year of actual age, but under estimated ages of wolves ???9 years old by 1-3 years. No differences were detected in tooth wear patterns for wild wolves from Alaska, Minnesota, and Ontario, nor between captive and wild wolves. Tooth wear was not appropriate for aging wolves with an underbite that prevented normal wear or severely broken and missing teeth.
Research on Oxidation Wear Behavior of a New Hot Forging Die Steel
NASA Astrophysics Data System (ADS)
Shi, Yuanji; Wu, Xiaochun
2018-01-01
Dry sliding tests for the hot forging die steel DM were performed in air under the test temperature at 400-700 °C and the time of 0.5-4 h by a UMT-3 high-temperature wear tester. The wear behavior and characteristics were studied systematically to explore the general characters in severe oxidation conditions. The results showed that a mild-to-severe oxidation wear transition occurred with an increase in the test temperature and duration. The reason was clarified as the unstable M6C carbides coarsening should be responsible for the severe delamination of tribo-oxide layer. More importantly, an intense oxidation wear with lower wear rates was found when the experimental temperature reaches 700 °C or after 4 h of test time at 600 °C, which was closely related to the degradation behavior during wear test. Furthermore, a new schematic diagram of oxidation wear of DM steel was proposed.
An investigation on dry sliding wear behaviour of AA6061-AlNp composite
NASA Astrophysics Data System (ADS)
Mahesh Naidu, K.; Mohan Reddy, Chandra
2018-03-01
This paper studies the effect of load, sliding distance, reinforcement percentage and temperature on dry sliding wear behaviour of Al-AlNp composites by using pin on disc machine. The wear test was conducted at different loads (1,2,3 & 4 Kg), temperatures (30°C, 100°C, 170°C & 240°C) and sliding distances (500m,1000m,1500m and 2000m). Increase in wear rate has been observed by increasing the load and sliding distance, at the same time it has been decreased by increasing the reinforcement percentage and temperature. At the higher loads, temperatures and sliding distances adhesive wear, abrasive wear and oxidation wear are observed to be dominant modes of wear mechanisms in the composite.
Friction and wear of human hair fibres
NASA Astrophysics Data System (ADS)
Bowen, James; Johnson, Simon A.; Avery, Andrew R.; Adams, Michael J.
2016-06-01
An experimental study of the tribological properties of hair fibres is reported, and the effect of surface treatment on the evolution of friction and wear during sliding. Specifically, orthogonally crossed fibre/fibre contacts under a compressive normal load over a series of 10 000 cycle studies are investigated. Reciprocating sliding at a velocity of 0.4 mm s-1, over a track length of 0.8 mm, was performed at 18 °C and 40%-50% relative humidity. Hair fibres retaining their natural sebum were studied, as well as those stripped of their sebum via hexane cleaning, and hair fibres conditioned using a commercially available product. Surface topography modifications resulting from wear were imaged using scanning electron microscopy and quantified using white light interferometry. Hair fibres that presented sebum or conditioned product at the fibre/fibre junction exhibited initial coefficients of friction at least 25% lower than those that were cleaned with hexane. Coefficients of friction were observed to depend on the directionality of sliding for hexane cleaned hair fibres after sufficient wear cycles that cuticle lifting was present, typically on the order 1000 cycles. Cuticle flattening was observed for fibre/fibre junctions exposed to 10 mN compressive normal loads, whereas loads of 100 mN introduced substantial cuticle wear and fibre damage.
Clinical pulmonary function and industrial respirator wear
DOE Office of Scientific and Technical Information (OSTI.GOV)
Raven, P.B.; Moss, R.F.; Page, K.
1981-12-01
This investigation was the initial step in determining a clinical pulmonary test which could be used to evaluate workers as to their suitability to industrial respirator wear. Sixty subjects, 12 superior, 37 normal, and 11 moderately impaired with respect to lung function tests were evaluated with a battery of clinical pulmonary tests while wearing an industrial respirator. The respirator was a full-face mask (MSA-Ultravue) demand breathing type equipped with an inspiratory resistance of 85mm H/sub 2/O at 85 L/min air flow and an expiratory resistance of 25mm H/sub 2/O at 85 L/min air flow. Comparisons of these tests were mademore » between the three groups of subjects both with and without a respirator. It appears that those lung tests which measure the flow characteristics of the lung especially those that are effort dependant are more susceptible to change as a result of respirator wear. Hence, the respirator affects the person with superior lung function to a greater degree than the moderately impaired person. It was suggested that the clinical test of 15 second maximum voluntary ventilations (MVV./sub 25/) may be the test of choice for determining worker capability in wearing an industrial respirator.« less
Risk factors for contact lens bacterial contamination during continuous wear.
Szczotka-Flynn, Loretta B; Bajaksouzian, Saralee; Jacobs, Michael R; Rimm, Alfred
2009-11-01
Microbial contamination of contact lenses is associated with corneal infection and inflammation. This study determined the microbiological, clinical, and demographic factors that are associated with bacterial contamination of a silicone hydrogel contact lens when worn for continuous wear (CW). Two hundred five healthy subjects were enrolled in the Longitudinal Analysis of Silicone Hydrogel Contact Lens Study and were fitted with lotrafilcon A lenses for monthly CW and followed for 1 year. Lenses were aseptically removed after 1 week and 4 months of wear and cultured using an agar sandwich technique. Lids and conjunctiva were routinely cultured at baseline and after 1 week and 4 months of CW. Lenses and ocular sites were considered to have substantial microbial bioburden when they harbored pathogenic organisms or high levels of commensal organisms. Univariate and multivariate logistic regression analyses were conducted to examine whether substantial conjunctival or lid bioburden, subject demographics, lens-wearing history, symptoms, and biomicroscopic signs were associated with lens bioburden. About one third (32.4%) of subjects had substantial bacterial bioburden in either eye across multiple visits. Over half (53.2%) and about one tenth (11.7%) of subjects had substantial lid and conjunctival bioburden, respectively, and 11.2% discontinued because of discomfort. The adjusted odds ratios (and 95% confidence intervals) for presence of substantial lens bioburden were 2.49 (1.17-5.30), 4.24 (1.45-12.40), and 4.11 (1.17-14.46) for substantial lid bioburden, substantial conjunctival bioburden, and lens discomfort, respectively. Bacterial contamination of silicone hydrogel contact lenses is common during CW. Substantial lens bioburden is associated with discomfort precluding successful CW. The presence of substantial lid and conjunctival bioburden is associated with a 2.5-fold and more than fourfold greater risk of substantial lens bioburden and is likely the major route
[Effect of surface modification using laser on wear resistance of titanium].
Sato, Yohei
2005-02-01
Severe wear of cast commercial pure (CP) titanium teeth was observed in a clinical survey. This study evaluated the wear resistance of cast CP titanium and titanium alloy teeth after the surface was modified using laser technology. Teeth patterns were duplicated from artificial first molars (Livdent FB30, GC, Japan). All teeth specimens were cast with CP Ti grade 3 (T-Alloy H, GC) and Ti-6Al-7Nb (T-Alloy Tough, GC). After the occlusal surface was blasted with Al(2)O(3), the occlusal contact points were modified using a laser (Neo laser L, Girrbach, Germany) at the following irradiation conditions (voltage: 260 V; pulse: 7 ms; focus: 1.5 mm). These parameters were determined by preliminary study. As a control, Type IV gold alloy (PGA-3, Ishifuku, Japan) was also cast conventionally. Both maxillary and mandibular teeth were worn using an in vitro two-body wear testing apparatus that simulated chewing function (60 strokes/min; grinding distance: 2 mm under flowing water). Wear resistance was assessed as volume loss (mm(3)) at 5 kgf (grinding force) after 50,000 strokes. The results (n=5) were analyzed by ANOVA/Scheffé's test (alpha=0.05). The gold alloy showed the best wear resistance of all the metals tested. Of all the titanium specimens tested, the modified surface indicated significantly greater wear resistance than did conventional titanium teeth without surface modification (p<0.05). Wear resistance was increased by modification of the surface using a laser. If severe wear of titanium teeth was observed clinically, little wear occurred when the occlusal facets were irradiated using a laser.
Computational Wear Simulation of Patellofemoral Articular Cartilage during In Vitro Testing
Li, Lingmin; Patil, Shantanu; Steklov, Nick; Bae, Won; Temple-Wong, Michele; D'Lima, Darryl D.; Sah, Robert L.; Fregly, Benjamin J.
2011-01-01
Though changes in normal joint motions and loads (e.g., following anterior cruciate ligament injury) contribute to the development of knee osteoarthritis, the precise mechanism by which these changes induce osteoarthritis remains unknown. As a first step toward identifying this mechanism, this study evaluates computational wear simulations of a patellofemoral joint specimen wear tested on a knee simulator machine. A multi-body dynamic model of the specimen mounted in the simulator machine was constructed in commercial computer-aided engineering software. A custom elastic foundation contact model was used to calculate contact pressures and wear on the femoral and patellar articular surfaces using geometry created from laser scan and MR data. Two different wear simulation approaches were investigated – one that wore the surface geometries gradually over a sequence of 10 one-cycle dynamic simulations (termed the “progressive” approach), and one that wore the surface geometries abruptly using results from a single one-cycle dynamic simulation (termed the “non-progressive” approach). The progressive approach with laser scan geometry reproduced the experimentally measured wear depths and areas for both the femur and patella. The less costly non-progressive approach predicted deeper wear depths, especially on the patella, but had little influence on predicted wear areas. Use of MR data for creating the articular and subchondral bone geometry altered wear depth and area predictions by at most 13%. These results suggest that MR-derived geometry may be sufficient for simulating articular cartilage wear in vivo and that a progressive simulation approach may be needed for the patella and tibia since both remain in continuous contact with the femur. PMID:21453922